7 CFR 201.42 - Small containers.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Small containers. 201.42 Section 201.42 Agriculture... REGULATIONS Sampling in the Administration of the Act § 201.42 Small containers. In sampling seed in small containers that it is not practical to sample as required in § 201.41, a portion of one unopened container or...
Thin layer chromatography residue applicator sampler
Nunes, Peter J [Danville, CA; Kelly, Fredrick R [Modesto, CA; Haas, Jeffrey S [San Ramon, CA; Andresen, Brian D [Livermore, CA
2007-07-24
A thin layer chromatograph residue applicator sampler. The residue applicator sampler provides for rapid analysis of samples containing high explosives, chemical warfare, and other analyses of interest under field conditions. This satisfied the need for a field-deployable, small, hand-held, all-in-one device for efficient sampling, sample dissolution, and sample application to an analytical technique. The residue applicator sampler includes a sampling sponge that is resistant to most chemicals and is fastened via a plastic handle in a hermetically sealed tube containing a known amount of solvent. Upon use, the wetted sponge is removed from the sealed tube and used as a swiping device across an environmental sample. The sponge is then replaced in the hermetically sealed tube where the sample remains contained and dissolved in the solvent. A small pipette tip is removably contained in the hermetically sealed tube. The sponge is removed and placed into the pipette tip where a squeezing-out of the dissolved sample from the sponge into the pipette tip results in a droplet captured in a vial for later instrumental analysis, or applied directly to a thin layer chromatography plate for immediate analysis.
NASA Technical Reports Server (NTRS)
Wingard, Charles Doug; Munafo, Paul M. (Technical Monitor)
2002-01-01
Protein crystals are grown in microgravity experiments inside the Space Shuttle during orbit. Such crystals are basically grown in a five-component system containing a salt, buffer, polymer, organic and water. During these experiments, a number of different polymeric containment materials must be compatible with up to hundreds of different PCG solutions in various concentrations for durations up to 180 days. When such compatibility experiments are performed at NASA/MSFC (Marshall Space Flight Center) simultaneously on containment material samples immersed in various solutions in vials, the samples are rather small out of necessity. DMA4 modulus was often used as the primary screening parameter for such small samples as a pass/fail criterion for incompatibility issues. In particular, the TA Instruments DMA 2980 film tension clamp was used to test rubber O-rings as small in I.D. as 0.091 in. by cutting through the cross-section at one place, then clamping the stretched linear cord stock at each end. The film tension clamp was also used to successfully test short length samples of medical/surgical grade tubing with an O.D. of 0.125 in.
In vitro platelet quality in storage containers used for pediatric transfusions.
Weiss, Sandra; Scammell, Kenneth; Levin, Elena; Culibrk, Brankica; Zolfaghari, Sima; Gyöngyössy-Issa, Maria I C; Acker, Jason P
2012-08-01
The in vitro quality of small-volume platelet (PLT) aliquots for pediatric transfusions was assessed to determine the best practice approach. Small volumes (50 mL) of single apheresis PLT components (APCs), collected on either CaridianBCT Trima or Haemonetics MCS+ instruments, were aliquoted on Days 2, 3, 4, and 5 postcollection into Fenwal PL1240 or 4R2014 bags or 60-mL polypropylene syringes. Samples were tested for in vitro quality at their recommended expiry times (4 hr for 4R2014 bags and syringes or Day 5 for PL1240 bags). Assays included pH, CD62P expression, and metabolic measures. CD62P expression increased throughout storage in all containers. Among the small-volume containers, pH, pCO(2) , lactate, and bicarbonate varied considerably. Regardless of the day of aliquoting, pCO(2) was significantly higher and pO(2) was significantly lower in gas-impermeable syringes than other containers. No bacterial growth was detected in any sample. The quality of APCs aliquoted into small-volume containers meets regulatory requirements and is generally equivalent to that of full-volume APCs at expiry. © 2012 American Association of Blood Banks.
Assessment of two thermally treated drill mud wastes for landfill containment applications.
Carignan, Marie-Pierre; Lake, Craig B; Menzies, Todd
2007-10-01
Offshore oil and gas drilling operations generate significant amounts of drill mud waste, some of which is transported onshore for subsequent thermal treatment (i.e. via thermal remediation). This treatment process results in a mineral waste by-product (referred to as thermally treated drill mud waste; TTDMW). Bentonites are originally present in many of the drill mud products and it is hypothesized that TTDMW can be utilized in landfill containment applications (i.e. cover or base liner). The objective of this paper is to examine the feasibility of this application by performing various physical and chemical tests on two TTDMW samples. It is shown that the two TTDMW samples contained relatively small amounts of clay-sized minerals although hydraulic conductivity values are found to be less than 10(-8) m/s. Organic carbon contents of the samples were approximately 2%. Mineralogy characterization of the samples confirmed varying amounts of smectite, however, peak friction angles for a TTDMW sample was greater than 36 degrees. Chemical characterization of the TTDMW samples show potential leaching of barium and small amounts of other heavy metals. Discussion is provided in the paper on suggestions to assist in overcoming regulatory issues associated with utilization of TTDMW in landfill containment applications.
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR METALS IN REPLICATE SAMPLES
The Metals in Replicate Samples data set contains the analytical results of measurements of up to 27 metals in 133 replicate (duplicate) samples from 62 households. Measurements were made in samples of soil, blood, tap water, and drinking water. Duplicate samples for a small pe...
An interface for the direct coupling of small liquid samples to AMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ognibene, T. J.; Thomas, A. T.; Daley, P. F.
We describe the moving wire interface attached to the 1-MV AMS system at LLNL’s Center for Accelerator Mass Spectrometry for the analysis of nonvolatile liquid samples as either discrete drops or from the direct output of biochemical separatory instrumentation, such as high-performance liquid chromatography (HPLC). Discrete samples containing at least a few 10 s of nanograms of carbon and as little as 50 zmol 14C can be measured with a 3–5% precision in a few minutes. The dynamic range of our system spans approximately 3 orders in magnitude. Sample to sample memory is minimized by the use of fresh targetsmore » for each discrete sample or by minimizing the amount of carbon present in a peak generated by an HPLC containing a significant amount of 14C. As a result, liquid sample AMS provides a new technology to expand our biomedical AMS program by enabling the capability to measure low-level biochemicals in extremely small samples that would otherwise be inaccessible.« less
An interface for the direct coupling of small liquid samples to AMS
Ognibene, T. J.; Thomas, A. T.; Daley, P. F.; ...
2015-05-28
We describe the moving wire interface attached to the 1-MV AMS system at LLNL’s Center for Accelerator Mass Spectrometry for the analysis of nonvolatile liquid samples as either discrete drops or from the direct output of biochemical separatory instrumentation, such as high-performance liquid chromatography (HPLC). Discrete samples containing at least a few 10 s of nanograms of carbon and as little as 50 zmol 14C can be measured with a 3–5% precision in a few minutes. The dynamic range of our system spans approximately 3 orders in magnitude. Sample to sample memory is minimized by the use of fresh targetsmore » for each discrete sample or by minimizing the amount of carbon present in a peak generated by an HPLC containing a significant amount of 14C. As a result, liquid sample AMS provides a new technology to expand our biomedical AMS program by enabling the capability to measure low-level biochemicals in extremely small samples that would otherwise be inaccessible.« less
The Metals in Replicate Samples data set contains the analytical results of measurements of up to 2 metals in 172 replicate (duplicate) samples from 86 households. Measurements were made in samples of blood. Duplicate samples for a small percentage of the total number of sample...
Contained radiological analytical chemistry module
Barney, David M.
1989-01-01
A system which provides analytical determination of a plurality of water chemistry parameters with respect to water samples subject to radiological contamination. The system includes a water sample analyzer disposed within a containment and comprising a sampling section for providing predetermined volumes of samples for analysis; a flow control section for controlling the flow through the system; and a gas analysis section for analyzing samples provided by the sampling system. The sampling section includes a controllable multiple port valve for, in one position, metering out sample of a predetermined volume and for, in a second position, delivering the material sample for analysis. The flow control section includes a regulator valve for reducing the pressure in a portion of the system to provide a low pressure region, and measurement devices located in the low pressure region for measuring sample parameters such as pH and conductivity, at low pressure. The gas analysis section which is of independent utility provides for isolating a small water sample and extracting the dissolved gases therefrom into a small expansion volume wherein the gas pressure and thermoconductivity of the extracted gas are measured.
Contained radiological analytical chemistry module
Barney, David M.
1990-01-01
A system which provides analytical determination of a plurality of water chemistry parameters with respect to water samples subject to radiological contamination. The system includes a water sample analyzer disposed within a containment and comprising a sampling section for providing predetermined volumes of samples for analysis; a flow control section for controlling the flow through the system; and a gas analysis section for analyzing samples provided by the sampling system. The sampling section includes a controllable multiple port valve for, in one position, metering out sample of a predetermined volume and for, in a second position, delivering the material sample for analysis. The flow control section includes a regulator valve for reducing the pressure in a portion of the system to provide a low pressure region, and measurement devices located in the low pressure region for measuring sample parameters such as pH and conductivity, at low pressure. The gas analysis section which is of independent utility provides for isolating a small water sample and extracting the dissolved gases therefrom into a small expansion volume wherein the gas pressure and thermoconductivity of the extracted gas are measured.
Fixture for supporting and aligning a sample to be analyzed in an x-ray diffraction apparatus
Green, L.A.; Heck, J.L. Jr.
1985-04-23
A fixture is provided for supporting and aligning small samples of material on a goniometer for x-ray diffraction analysis. A sample-containing capillary is accurately positioned for rotation in the x-ray beam by selectively adjusting the fixture to position the capillary relative to the x and y axes thereof to prevent wobble and position the sample along the z axis or the axis of rotation. By employing the subject fixture relatively small samples of materials can be analyzed in an x-ray diffraction apparatus previously limited to the analysis of much larger samples.
Fixture for supporting and aligning a sample to be analyzed in an X-ray diffraction apparatus
Green, Lanny A.; Heck, Jr., Joaquim L.
1987-01-01
A fixture is provided for supporting and aligning small samples of material on a goniometer for X-ray diffraction analysis. A sample-containing capillary is accurately positioned for rotation in the X-ray beam by selectively adjusting the fixture to position the capillary relative to the x and y axes thereof to prevent wobble and position the sample along the z axis or the axis of rotation. By employing the subject fixture relatively small samples of materials can be analyzed in an X-ray diffraction apparatus previously limited to the analysis of much larger samples.
Cheng, Lei; Wu, Cheng Hao; Jarry, Angelique; Chen, Wei; Ye, Yifan; Zhu, Junfa; Kostecki, Robert; Persson, Kristin; Guo, Jinghua; Salmeron, Miquel; Chen, Guoying; Doeff, Marca
2015-08-19
The interfacial resistances of symmetrical lithium cells containing Al-substituted Li7La3Zr2O12 (LLZO) solid electrolytes are sensitive to their microstructures and histories of exposure to air. Air exposure of LLZO samples with large grain sizes (∼150 μm) results in dramatically increased interfacial impedances in cells containing them, compared to those with pristine large-grained samples. In contrast, a much smaller difference is seen between cells with small-grained (∼20 μm) pristine and air-exposed LLZO samples. A combination of soft X-ray absorption (sXAS) and Raman spectroscopy, with probing depths ranging from nanometer to micrometer scales, revealed that the small-grained LLZO pellets are more air-stable than large-grained ones, forming far less surface Li2CO3 under both short- and long-term exposure conditions. Surface sensitive X-ray photoelectron spectroscopy (XPS) indicates that the better chemical stability of the small-grained LLZO is related to differences in the distribution of Al and Li at sample surfaces. Density functional theory calculations show that LLZO can react via two different pathways to form Li2CO3. The first, more rapid, pathway involves a reaction with moisture in air to form LiOH, which subsequently absorbs CO2 to form Li2CO3. The second, slower, pathway involves direct reaction with CO2 and is favored when surface lithium contents are lower, as with the small-grained samples. These observations have important implications for the operation of solid-state lithium batteries containing LLZO because the results suggest that the interfacial impedances of these devices is critically dependent upon specific characteristics of the solid electrolyte and how it is prepared.
Huang, Zixia; Gallot, Aurore; Lao, Nga T; Puechmaille, Sébastien J; Foley, Nicole M; Jebb, David; Bekaert, Michaël; Teeling, Emma C
2016-01-01
The acquisition of tissue samples from wild populations is a constant challenge in conservation biology, especially for endangered species and protected species where nonlethal sampling is the only option. Whole blood has been suggested as a nonlethal sample type that contains a high percentage of bodywide and genomewide transcripts and therefore can be used to assess the transcriptional status of an individual, and to infer a high percentage of the genome. However, only limited quantities of blood can be nonlethally sampled from small species and it is not known if enough genetic material is contained in only a few drops of blood, which represents the upper limit of sample collection for some small species. In this study, we developed a nonlethal sampling method, the laboratory protocols and a bioinformatic pipeline to sequence and assemble the whole blood transcriptome, using Illumina RNA-Seq, from wild greater mouse-eared bats (Myotis myotis). For optimal results, both ribosomal and globin RNAs must be removed before library construction. Treatment of DNase is recommended but not required enabling the use of smaller amounts of starting RNA. A large proportion of protein-coding genes (61%) in the genome were expressed in the blood transcriptome, comparable to brain (65%), kidney (63%) and liver (58%) transcriptomes, and up to 99% of the mitogenome (excluding D-loop) was recovered in the RNA-Seq data. In conclusion, this nonlethal blood sampling method provides an opportunity for a genomewide transcriptomic study of small, endangered or critically protected species, without sacrificing any individuals. © 2015 John Wiley & Sons Ltd.
Low Cost Mars Sample Return Utilizing Dragon Lander Project
NASA Technical Reports Server (NTRS)
Stoker, Carol R.
2014-01-01
We studied a Mars sample return (MSR) mission that lands a SpaceX Dragon Capsule on Mars carrying sample collection hardware (an arm, drill, or small rover) and a spacecraft stack consisting of a Mars Ascent Vehicle (MAV) and Earth Return Vehicle (ERV) that collectively carry the sample container from Mars back to Earth orbit.
Application of dual-energy x-ray techniques for automated food container inspection
NASA Astrophysics Data System (ADS)
Shashishekhar, N.; Veselitza, D.
2016-02-01
Manufacturing for plastic food containers often results in small metal particles getting into the containers during the production process. Metal detectors are usually not sensitive enough to detect these metal particles (0.5 mm or lesser), especially when the containers are stacked in large sealed shipping packages; X-ray inspection of these packages provides a viable alternative. This paper presents the results of an investigation into dual-energy X-ray techniques for automated detection of small metal particles in plastic food container packages. The sample packages consist of sealed cardboard boxes containing stacks of food containers: plastic cups for food, and Styrofoam cups for noodles. The primary goal of the investigation was to automatically identify small metal particles down to 0.5 mm diameter in size or less, randomly located within the containers. The multiple container stacks in each box make it virtually impossible to reliably detect the particles with single-energy X-ray techniques either visually or with image processing. The stacks get overlaid in the X-ray image and create many indications almost identical in contrast and size to real metal particles. Dual-energy X-ray techniques were investigated and found to result in a clear separation of the metal particles from the food container stack-ups. Automated image analysis of the resulting images provides reliable detection of the small metal particles.
Capece, Paula I; Aliaga-Rossel, Enzo; Jansen, Patrick A
2013-03-01
Tapirs are known as effective dispersers of large-seeded tree species, but their role in dispersing small-seeded plant species has yet to be established. Tapir feces have been reported to contain large numbers of small seeds, but whether these are viable has rarely been evaluated. We determined the abundance and viability of small seeds in feces of Central American tapir (Tapirus bairdii) on Barro Colorado Island, Panama. A total of 72 fecal samples were collected opportunistically from 4 tapir latrine sites. Seeds were manually extracted from feces and classified by size. Seed viability was estimated by opening each seed and examining for the presence of at least 1 intact firm white endosperm. In total, we obtained 8166 seeds of at least 16 plant species. Small-seeded species dominated, with 96% of all seeds found measuring <5 mm. The canopy tree Laetia procera was the most abundant species in the samples. Of all small seeds found, 69% contained an intact endosperm and appeared viable. This suggests that small seeds, like large seeds, often pass through the digestive tract of T. bairdii intact. Thus, tapirs potentially serve as effective dispersers of a wide range of small-seeded plant species. © 2012 Wiley Publishing Asia Pty Ltd, ISZS and IOZ/CAS.
Study of sample drilling techniques for Mars sample return missions
NASA Technical Reports Server (NTRS)
Mitchell, D. C.; Harris, P. T.
1980-01-01
To demonstrate the feasibility of acquiring various surface samples for a Mars sample return mission the following tasks were performed: (1) design of a Mars rover-mounted drill system capable of acquiring crystalline rock cores; prediction of performance, mass, and power requirements for various size systems, and the generation of engineering drawings; (2) performance of simulated permafrost coring tests using a residual Apollo lunar surface drill, (3) design of a rock breaker system which can be used to produce small samples of rock chips from rocks which are too large to return to Earth, but too small to be cored with the Rover-mounted drill; (4)design of sample containers for the selected regolith cores, rock cores, and small particulate or rock samples; and (5) design of sample handling and transfer techniques which will be required through all phase of sample acquisition, processing, and stowage on-board the Earth return vehicle. A preliminary design of a light-weight Rover-mounted sampling scoop was also developed.
Carbon-14 dating of small samples by proportional counting.
Harbottle, G; Sayre, E V; Stoenner, R W
1979-11-09
Conventional carbon-14 dating by means of gas proportional counters has been extended to samples containing as little as 10 milligrams of carbon. The accuracy of the dating procedure has been checked by dating sequoia tree-ring samples of the 1st century A.D. and B.C. and an oak tree-ring sample of the 19th century A.D.
Tool for Sampling Permafrost on a Remote Planet
NASA Technical Reports Server (NTRS)
Peters, Gregory
2006-01-01
A report discusses the robotic arm tool for rapidly acquiring permafrost (RATRAP), which is being developed for acquiring samples of permafrost on Mars or another remote planet and immediately delivering the samples to adjacent instruments for analysis. The prototype RATRAP includes a rasp that protrudes through a hole in the bottom of a container that is placed in contact with the permafrost surface. Moving at high speed, the rasp cuts into the surface and loads many of the resulting small particles of permafrost through the hole into the container. The prototype RATRAP has been shown to be capable of acquiring many grams of permafrost simulants in times of the order of seconds. In contrast, a current permafrost sampling system that the RATRAP is intended to supplant works by scraping with tines followed by picking up the scrapings in a scoop, sometimes taking hours to acquire a few grams. Also, because the RATRAP inherently pulverizes the sampled material, it is an attractive alternative to other sampling apparatuses that generate core or chunk samples that must be further processed by a crushing apparatus to make the sample particles small enough for analysis by some instruments.
Entrepreneur Training Program. Getting Started.
ERIC Educational Resources Information Center
De Maria, Richard
This student workbook on starting a small business is part of the entrepreneur training program at Ocean County (New Jersey) Vocational-Technical Schools. The workbook consists of 16 units containing goals and objectives, study questions, exercises, sample materials, and information sheets. Unit topics are as follows: being a small business owner;…
Mini-tapping sugar maples for sap-sugar testing
William J. Gabriel
1982-01-01
Describes a technique using cannulas, surgical tubing, and small containers to obtain sap samples for use in determining the sugar content of sap in small sugar maple trees. This technique is used on trees directly exposed to the weather, and sets a minimum tappable tree diameter of 1.5 cm.
A novel ultrasonic aerosol generator.
Davies, A; Hudson, N; Pirie, L
1995-07-01
An ultrasonic aerosol generator constructed from a domestic humidifier is described which has been used to produce liquid aerosols for physiological investigations. The instrument was constructed from a Pifco domestic humidifier modified to include an energy guide to direct the oscillations of the transducer through the coupling water, which would normally be aerosolized, onto a small membrane based sample chamber containing the liquid to be aerosolized. The size distribution of the aerosol produced was found to be between 2 and 6 mm, optimum for diffuse intrapulmonary deposition. Up to 4 ml/min of aqueous liquid was used; however the sample chamber could be made small enough to contain economic amounts of expensive material to administer by inhalation. The instrument has proved to be reliable over a period of three years.
Focusing particle concentrator with application to ultrafine particles
Hering, Susanne; Lewis, Gregory; Spielman, Steven R.
2013-06-11
Technology is presented for the high efficiency concentration of fine and ultrafine airborne particles into a small fraction of the sampled airflow by condensational enlargement, aerodynamic focusing and flow separation. A nozzle concentrator structure including an acceleration nozzle with a flow extraction structure may be coupled to a containment vessel. The containment vessel may include a water condensation growth tube to facilitate the concentration of ultrafine particles. The containment vessel may further include a separate carrier flow introduced at the center of the sampled flow, upstream of the acceleration nozzle of the nozzle concentrator to facilitate the separation of particle and vapor constituents.
Collison, Mark W.
2008-01-01
An interlaboratory study was conducted to evaluate a method for determining total soy isoflavones in dietary supplements, dietary supplement ingredients, and soy foods. Isoflavones were extracted using aqueous acetonitrile containing a small amount of dimethylsulfoxide (DMSO) and all 12 of the naturally occuring isoflavones in soy were determined by high-performance liquid Chromatography (HPLC) with UV detection using apigenin as an internal standard. Fifteen samples (6 pairs of blind duplicates plus 3 additional samples) of soy isoflavone ingredients, soy isoflavone dietary supplements, soy flour, and soy protein products were successfully analyzed by 13 collaborating laboratories in 6 countries. For repeatability, the relative standard deviations (RSDr) ranged from 1.07 for samples containing over 400 mg/g total isoflavones to 3.31 for samples containing 0.87 mg/g total isoflavones, and for reproducibility the RSDR values ranged from 2.29 for samples containing over 400 mg/g total isoflavones to 9.36 for samples containing 0.87 mg/g total isoflavones. HorRat values ranged from 1.00 to 1.62 for all samples containing at least 0.8 mg/g total isoflavones. One sample, containing very low total isoflavones (<0.05 mg/g), gave RSDR values of 175 and a HorRat value of 17.6. This sample was deemed to be below the usable range of the method. The method provides accurate and precise results for analysis of soy isoflavones in dietary supplements and soy foods. PMID:18567292
Collison, Mark W
2008-01-01
An interlaboratory study was conducted to evaluate a method for determining total soy isoflavones in dietary supplements, dietary supplement ingredients, and soy foods. Isoflavones were extracted using aqueous acetonitrile containing a small amount of dimethylsulfoxide (DMSO) and all 12 of the naturally occuring isoflavones in soy were determined by high-performance liquid chromatography (HPLC) with UV detection using apigenin as an internal standard. Fifteen samples (6 pairs of blind duplicates plus 3 additional samples) of soy isoflavone ingredients, soy isoflavone dietary supplements, soy flour, and soy protein products were successfully analyzed by 13 collaborating laboratories in 6 countries. For repeatability, the relative standard deviations (RSDr) ranged from 1.07 for samples containing over 400 mglg total isoflavones to 3.31 for samples containing 0.87 mg/g total isoflavones, and for reproducibility the RSDR values ranged from 2.29 for samples containing over 400 mg/g total isoflavones to 9.36 for samples containing 0.87 mg/g total isoflavones. HorRat values ranged from 1.00 to 1.62 for all samples containing at least 0.8 mg/g total isoflavones. One sample, containing very low total isoflavones (< 0.05 mg/g), gave RSDR values of 175 and a HorRat value of 17.6. This sample was deemed to be below the usable range of the method. The method provides accurate and precise results for analysis of soy isoflavones in dietary supplements and soy foods.
Population Education in Science: Some Sample Lessons.
ERIC Educational Resources Information Center
United Nations Educational, Scientific, and Cultural Organization, Bangkok (Thailand). Regional Office for Education in Asia and Oceania.
This science teacher's manual contains nine sample population education lessons adapted from materials produced in several countries in Asia and Oceania. Activities are designed for lower primary through high school students. Included are class discussions, small group activities, and a role-playing situation. Food chains, human dependence upon…
Synthesis and characterization of cerium containing iron phosphate based glass-ceramics
NASA Astrophysics Data System (ADS)
Deng, Yi; Liao, Qilong; Wang, Fu; Zhu, Hanzhen
2018-02-01
The structure and properties of xCeO2-(100-x)(40Fe2O3-60P2O5), where x = 0, 2, 4, 6 and 8 mol%, glass-ceramics prepared by melting and slow cooling method have been investigated by using X-ray diffraction (XRD), scanning electron microscope (SEM), Fourier transform infrared spectroscopy (FTIR), differential thermal analysis (DTA) and the Product Consistency Test (PCT). The results show that the 40Fe2O3-60P2O5 sample is homogeneously amorphous and the sample containing 2 mol% CeO2 has a small amount of FePO4 phase embedded. For the sample containing up to 4 mol% CeO2, monazite CePO4 and a small amount of FePO4 appear. Spectra analysis show that the structure networks of the glass-ceramics mainly consist of orthophosphate, along with pyrophosphate and a small amount of metaphosphate units. Moreover, the leaching rates of Fe and Ce are about 3.5 × 10-5 g m-2 d-1 and 5.0 × 10-5 g m-2 d-1 respectively after immersion in deionized water at 90 °C for 56 days, indicating their good chemical durability. The conclusions imply that the prepared method may be a promising process to immobilize nuclear waste into glass-ceramic matrix.
Anomaly detection in reconstructed quantum states using a machine-learning technique
NASA Astrophysics Data System (ADS)
Hara, Satoshi; Ono, Takafumi; Okamoto, Ryo; Washio, Takashi; Takeuchi, Shigeki
2014-02-01
The accurate detection of small deviations in given density matrices is important for quantum information processing. Here we propose a method based on the concept of data mining. We demonstrate that the proposed method can more accurately detect small erroneous deviations in reconstructed density matrices, which contain intrinsic fluctuations due to the limited number of samples, than a naive method of checking the trace distance from the average of the given density matrices. This method has the potential to be a key tool in broad areas of physics where the detection of small deviations of quantum states reconstructed using a limited number of samples is essential.
Selection of 3013 Containers for Field Surveillance. Fiscal Year 2016 Update
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, Elizabeth J.; Berg, John M.; Cheadle, Jesse
2016-04-19
This update is the eighth in a series of reports that document the binning and sample selection of 3013 containers for the Field Surveillance program as part of the Integrated Surveillance Program. This report documents changes made to both the container binning assignments and the sample selection approach. Binning changes documented in this update are a result of changes to the prompt gamma calibration curves and the reassignment of a small number of Hanford items from the Pressure bin to the Pressure and Corrosion (P&C) bin. Field Surveillance sample selection changes are primarily a result of focusing future destructive examinationsmore » (DEs) on the potential for stress corrosion cracking in higher moisture containers in the P&C bin. The decision to focus the Field Surveillance program on higher moisture items is based on findings from both the Shelf-life testing program and DEs.« less
Wider-Opening Dewar Flasks for Cryogenic Storage
NASA Technical Reports Server (NTRS)
Ruemmele, Warren P.; Manry, John; Stafford, Kristin; Bue, Grant; Krejci, John; Evernden, Bent
2010-01-01
Dewar flasks have been proposed as containers for relatively long-term (25 days) storage of perishable scientific samples or other perishable objects at a temperature of 175 C. The refrigeration would be maintained through slow boiling of liquid nitrogen (LN2). For the purposes of the application for which these containers were proposed, (1) the neck openings of commercial off-the-shelf (COTS) Dewar flasks are too small for most NASA samples; (2) the round shapes of the COTS containers give rise to unacceptably low efficiency of packing in rectangular cargo compartments; and (3) the COTS containers include metal structures that are too thermally conductive, such that they cannot, without exceeding size and weight limits, hold enough LN2 for the required long-term-storage. In comparison with COTS Dewar flasks, the proposed containers would be rectangular, yet would satisfy the long-term storage requirement without exceeding size and weight limits; would have larger neck openings; and would have greater sample volumes, leading to a packing efficiency of about double the sample volume as a fraction of total volume. The proposed containers would be made partly of aerospace- type composite materials and would include vacuum walls, multilayer insulation, and aerogel insulation.
Quantitation of glycerophosphorylcholine by flow injection analysis using immobilized enzymes.
Mancini, A; Del Rosso, F; Roberti, R; Caligiana, P; Vecchini, A; Binaglia, L
1996-09-20
A method for quantitating glycerophosphorylcholine by flow injection analysis is reported in the present paper. Glycerophosphorylcholine phosphodiesterase and choline oxidase, immobilized on controlled porosity glass beads, are packed in a small reactor inserted in a flow injection manifold. When samples containing glycerophosphorylcholine are injected, glycerophosphorylcholine is hydrolyzed into choline and sn-glycerol-3-phosphate. The free choline produced in this reaction is oxidized to betain and hydrogen peroxide. Hydrogen peroxide is detected amperometrically. Quantitation of glycerophosphorylcholine in samples containing choline and phosphorylcholine is obtained inserting ahead of the reactor a small column packed with a mixed bed ion exchange resin. The time needed for each determination does not exceed one minute. The present method, applied to quantitate glycerophosphorylcholine in samples of seminal plasma, gave results comparable with those obtained using the standard enzymatic-spectrophotometric procedure. An alternative procedure, making use of co-immobilized glycerophosphorylcholine phosphodiesterase and glycerol-3-phosphate oxidase for quantitating glycerophosphorylcholine, glycerophosphorylethanolamine and glycerophosphorylserine is also described.
NASA Astrophysics Data System (ADS)
Allen, Samantha D. M.; Almond, Matthew J.; Bell, Martin G.; Hollins, Peter; Marks, Sonja; Mortimore, Joanne L.
2002-03-01
The mineralogy of 11 concretions from the Bronze Age settlement horizons at Brean Down near Weston-super-Mare, Somerset, UK, has been examined by infrared spectroscopy. The concretions are found to contain calcite and apatite and, in some cases, quartz. Four further concretions from the later Iron Age Meare Village, soil samples from Brean Down and mineralised samples of known faecal origin from a cesspit within the Tudor Merchant's house in Tenby have been similarly examined. It is found that all samples contain calcite, but only the concretions and the Tenby cesspit samples contain apatite. None of the soil samples contain apatite, although these are relatively high in quartz. This suggests that the concretions are coprolites and that the apatite has a biological origin in small bone fragments. The infrared study is backed up by scanning electron microscopy which confirms the presence of phosphorus in the coprolite samples and shows a morphology suggestive of the presence of bone fragments; it is likely, therefore, that the coprolites result from a carnivore—most probably from dogs. The findings show the usefulness of infrared spectroscopy for the rapid identification of mineralised coprolitic material from archaeological sites.
Dowall, Stuart D; Graham, Victoria A; Tipton, Thomas R W; Hewson, Roger
2009-08-31
Work with highly pathogenic material mandates the use of biological containment facilities, involving microbiological safety cabinets and specialist laboratory engineering structures typified by containment level 3 (CL3) and CL4 laboratories. Consequences of working in high containment are the practical difficulties associated with containing specialist assays and equipment often essential for experimental analyses. In an era of increased interest in biodefence pathogens and emerging diseases, immunological analysis has developed rapidly alongside traditional techniques in virology and molecular biology. For example, in order to maximise the use of small sample volumes, multiplexing has become a more popular and widespread approach to quantify multiple analytes simultaneously, such as cytokines and chemokines. The luminex microsphere system allows for the detection of many cytokines and chemokines in a single sample, but the detection method of using aligned lasers and fluidics means that samples often have to be analysed in low containment facilities. In order to perform cytokine analysis in materials from high containment (CL3 and CL4 laboratories), we have developed an appropriate inactivation methodology after staining steps, which although results in a reduction of median fluorescent intensity, produces statistically comparable outcomes when judged against non-inactivated samples. This methodology thus extends the use of luminex technology for material that contains highly pathogenic biological agents.
Airborne asbestos in public buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chesson, J.; Hatfield, J.; Schultz, B.
The U.S. Environmental Protection Agency sampled air in 49 government-owned buildings (six buildings with no asbestos-containing material, six buildings with asbestos-containing material in generally good condition, and 37 buildings with damaged asbestos-containing material). This is the most comprehensive study to date of airborne asbestos levels in U.S. public buildings during normal building activities. The air outside each building was also sampled. Air samples were analyzed by transmission electron microscopy using a direct transfer preparation technique. The results show an increasing trend in average airborne asbestos levels; outdoor levels are lowest and levels in buildings with damaged asbestos-containing material are highest.more » However, the measured levels and the differences between indoors and outdoors and between building categories are small in absolute magnitude. Comparable studies from Canada and the UK, although differing in their estimated concentrations, also conclude that while airborne asbestos levels may be elevated in buildings that contain asbestos, levels are generally low. This conclusion does not eliminate the possibility of higher airborne asbestos levels during maintenance or renovation that disturbs the asbestos-containing material.« less
A high-throughput microRNA expression profiling system.
Guo, Yanwen; Mastriano, Stephen; Lu, Jun
2014-01-01
As small noncoding RNAs, microRNAs (miRNAs) regulate diverse biological functions, including physiological and pathological processes. The expression and deregulation of miRNA levels contain rich information with diagnostic and prognostic relevance and can reflect pharmacological responses. The increasing interest in miRNA-related research demands global miRNA expression profiling on large numbers of samples. We describe here a robust protocol that supports high-throughput sample labeling and detection on hundreds of samples simultaneously. This method employs 96-well-based miRNA capturing from total RNA samples and on-site biochemical reactions, coupled with bead-based detection in 96-well format for hundreds of miRNAs per sample. With low-cost, high-throughput, high detection specificity, and flexibility to profile both small and large numbers of samples, this protocol can be adapted in a wide range of laboratory settings.
Acoustically levitated droplets: a contactless sampling method for fluorescence studies.
Leiterer, Jork; Grabolle, Markus; Rurack, Knut; Resch-Genger, Ute; Ziegler, Jan; Nann, Thomas; Panne, Ulrich
2008-01-01
Acoustic levitation is used as a new tool to study concentration-dependent processes in fluorescence spectroscopy. With this technique, small amounts of liquid and solid samples can be measured without the need for sample supports or containers, which often limits signal acquisition and can even alter sample properties due to interactions with the support material. We demonstrate that, because of the small sample volume, fluorescence measurements at high concentrations of an organic dye are possible without the limitation of inner-filter effects, which hamper such experiments in conventional, cuvette-based measurements. Furthermore, we show that acoustic levitation of liquid samples provides an experimentally simple way to study distance-dependent fluorescence modulations in semiconductor nanocrystals. The evaporation of the solvent during levitation leads to a continuous increase of solute concentration and can easily be monitored by laser-induced fluorescence.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oshtrakh, M. I.; Novikov, E. G.; Semionkin, V. A.
2010-07-13
A study of several samples of vitamins and dietary supplements containing ferrous fumarate and ferrous sulfate was carried out using Moessbauer spectroscopy with a high velocity resolution. A presence of ferrous and ferric impurities was revealed. Small variations of Moessbauer hyperfine parameters were found for both ferrous fumarates and ferrous sulfates in the investigated medicines.
How Significant Is a Boxplot Outlier?
ERIC Educational Resources Information Center
Dawson, Robert
2011-01-01
It is common to consider Tukey's schematic ("full") boxplot as an informal test for the existence of outliers. While the procedure is useful, it should be used with caution, as at least 30% of samples from a normally-distributed population of any size will be flagged as containing an outlier, while for small samples (N less than 10) even extreme…
[Laser microdissection for biology and medicine].
Podgornyĭ, O V; Lazarev, V N; Govorun, V M
2012-01-01
For routine extraction of DNA, RNA, proteins and metabolites, small tissue pieces are placed into lysing solution. These tissue pieces in general contain different cell types. For this reason, lysate contains components of different cell types, which complicates the interpretation of molecular analysis results. The laser microdissection allows overcoming this trouble. The laser microdissection is a method to procure tissue samples contained defined cell subpopulations, individual cells and even subsellular components under direct microscopic visualization. Collected samples can be undergone to different downstream molecular assays: DNA analysis, RNA transcript profiling, cDNA library generation and gene expression analysis, proteomic analysis and metabolite profiling. The laser microdissection has wide applications in oncology (research and routine), cellular and molecular biology, biochemistry and forensics. This paper reviews the principles of different laser microdissection instruments, examples of laser microdissection application and problems of sample preparation for laser microdissection.
Determination of small quantities of fluoride in water: A modified zirconium-alizarin method
Lamar, W.L.; Seegmiller, C.G.
1941-01-01
The zirconium-alizarin method has been modified to facilitate the convenient and accurate determination of small amounts of fluoride in a large number of water samples. Sulfuric acid is used to acidify the samples to reduce the interference of sulfate. The pH is accurately controlled to give the most sensitive comparisons. Most natural waters can be analyzed by the modified procedure without resorting to correction curves. The fluoride content of waters containing less than 500 parts per million of sulfate, 500 parts per million of bicarbonate, and 1000 parts per million of chloride may be determined within a limit of about 0.1 part per million when a 100-ml. sample is used.
Efficient Estimation of the Standardized Value
ERIC Educational Resources Information Center
Longford, Nicholas T.
2009-01-01
We derive an estimator of the standardized value which, under the standard assumptions of normality and homoscedasticity, is more efficient than the established (asymptotically efficient) estimator and discuss its gains for small samples. (Contains 1 table and 3 figures.)
NASA Astrophysics Data System (ADS)
Sitek, M.; Szymański, M. K.; Udalski, A.; Skowron, D. M.; Kostrzewa-Rutkowska, Z.; Skowron, J.; Karczmarek, P.; Cieślar, M.; Wyrzykowski, Ł.; Kozłowski, S.; Pietrukowicz, P.; Soszyński, I.; Mróz, P.; Pawlak, M.; Poleski, R.; Ulaczyk, K.
2017-12-01
The Magellanic System (MS) encompasses the nearest neighbors of the Milky Way, the Large (LMC) and Small (SMC) Magellanic Clouds, and the Magellanic Bridge (MBR). This system contains a diverse sample of star clusters. Their parameters, such as the spatial distribution, chemical composition and age distribution yield important information about the formation scenario of the whole Magellanic System. Using deep photometric maps compiled in the fourth phase of the Optical Gravitational Lensing Experiment (OGLE-IV) we present the most complete catalog of star clusters in the Magellanic System ever constructed from homogeneous, long time-scale photometric data. In this second paper of the series, we show the collection of star clusters found in the area of about 360 square degrees in the MBR and in the outer regions of the SMC. Our sample contains 198 visually identified star cluster candidates, 75 of which were not listed in any of the previously published catalogs. The new discoveries are mainly young small open clusters or clusters similar to associations.
OGLE Collection of Star Clusters. New Objects in the Outskirts of the Large Magellanic Cloud
NASA Astrophysics Data System (ADS)
Sitek, M.; Szymański, M. K.; Skowron, D. M.; Udalski, A.; Kostrzewa-Rutkowska, Z.; Skowron, J.; Karczmarek, P.; Cieślar, M.; Wyrzykowski, Ł.; Kozłowski, S.; Pietrukowicz, P.; Soszyński, I.; Mróz, P.; Pawlak, M.; Poleski, R.; Ulaczyk, K.
2016-09-01
The Magellanic System (MS), consisting of the Large Magellanic Cloud (LMC), the Small Magellanic Cloud (SMC) and the Magellanic Bridge (MBR), contains diverse sample of star clusters. Their spatial distribution, ages and chemical abundances may provide important information about the history of formation of the whole System. We use deep photometric maps derived from the images collected during the fourth phase of the Optical Gravitational Lensing Experiment (OGLE-IV) to construct the most complete catalog of star clusters in the Large Magellanic Cloud using the homogeneous photometric data. In this paper we present the collection of star clusters found in the area of about 225 square degrees in the outer regions of the LMC. Our sample contains 679 visually identified star cluster candidates, 226 of which were not listed in any of the previously published catalogs. The new clusters are mainly young small open clusters or clusters similar to associations.
Using acoustic levitation in synchrotron based laser pump hard x-ray probe experiments
NASA Astrophysics Data System (ADS)
Hu, Bin; Lerch, Jason; Suthar, Kamlesh; Dichiara, Anthony
Acoustic levitation provides a platform to trap and hold a small amount of material by using standing pressure waves without a container. The technique has a potential to be used for laser pump x-ray probe experiments; x-ray scattering and laser distortion from the container can be avoided, sample consumption can be minimized, and unwanted chemistry that may occur at the container interface can be avoided. The method has been used at synchrotron sources for studying protein and pharmaceutical solutions using x-ray diffraction (XRD) and small angle x-ray scattering (SAXS). However, pump-probe experiments require homogeneously excited samples, smaller than the absorption depth of the material that must be held stably at the intersection of both the laser and x-ray beams. We discuss 1) the role of oscillations in acoustic levitation and the optimal acoustic trapping conditions for x-ray/laser experiments, 2) opportunities to automate acoustic levitation for fast sample loading and manipulation, and 3) our experimental results using SAXS to monitor laser induced thermal expansion in gold nanoparticles solution. We also performed Finite Element Analysis to optimize the trapping performance and stability of droplets ranging from 0.4 mm to 2 mm. Our early x-ray/laser demonstrated the potential of the technique for time-resolved X-ray science.
Mariella, Jr., Raymond P.
2018-03-06
An isotachophoresis system for separating a sample containing particles into discrete packets including a flow channel, the flow channel having a large diameter section and a small diameter section; a negative electrode operably connected to the flow channel; a positive electrode operably connected to the flow channel; a leading carrier fluid in the flow channel; a trailing carrier fluid in the flow channel; and a control for separating the particles in the sample into discrete packets using the leading carrier fluid, the trailing carrier fluid, the large diameter section, and the small diameter section.
How accurate is the Pearson r-from-Z approximation? A Monte Carlo simulation study.
Hittner, James B; May, Kim
2012-01-01
The Pearson r-from-Z approximation estimates the sample correlation (as an effect size measure) from the ratio of two quantities: the standard normal deviate equivalent (Z-score) corresponding to a one-tailed p-value divided by the square root of the total (pooled) sample size. The formula has utility in meta-analytic work when reports of research contain minimal statistical information. Although simple to implement, the accuracy of the Pearson r-from-Z approximation has not been empirically evaluated. To address this omission, we performed a series of Monte Carlo simulations. Results indicated that in some cases the formula did accurately estimate the sample correlation. However, when sample size was very small (N = 10) and effect sizes were small to small-moderate (ds of 0.1 and 0.3), the Pearson r-from-Z approximation was very inaccurate. Detailed figures that provide guidance as to when the Pearson r-from-Z formula will likely yield valid inferences are presented.
A method of isolating organic compounds present in water
NASA Technical Reports Server (NTRS)
Calder, G. V.; Fritz, J.; Junk, G. A.
1972-01-01
Water sample is passed through a column containing macroreticular resin, which absorbs only nonionic organic compounds. These compounds are selectively separated using aqueous eluents of varying pH, or completely exuded with small amount of an organic eluent.
Mössbauer study of iron minerals transformations by Fuchsiella ferrireducens
NASA Astrophysics Data System (ADS)
Gracheva, M. A.; Chistyakova, N. I.; Antonova, A. V.; Rusakov, V. S.; Zhilina, T. N.; Zavarzina, D. G.
2017-11-01
Biogenic transformations of iron-containing minerals synthesized ferrihydrite, magnetite and hydrothermal siderite by anaerobic alkaliphilic bacterium Fuchsiella ferrireducens (strain Z-7101T) were studied by 57Fe Mössbauer spectroscopy. Mössbauer investigations of solid phase samples obtained after microbial transformation were carried out at room temperature and at 82 K. It was found that all tested minerals transformed during bacterial growth. In the presence of synthesized ferrihydrite, added as an electron acceptor, a mixture of large (more than 100 nm) and small (˜5 nm) particles of magnetically ordered phase and siderite was formed. Synthesized magnetite that contains both Fe3+ and Fe2+ forms could serve as electron acceptor as well as an electron donor for F.ferrireducens growth. As a result of its biotransformation, no siderite formation was observed while small particles of magnetite were formed. In the case of the addition of siderite as an electron donor formation of a small amount of a new phase containing Fe2+ caused by recrystallization of siderite during bacterial growth was detected.
Trefz, Phillip; Rösner, Lisa; Hein, Dietmar; Schubert, Jochen K; Miekisch, Wolfram
2013-04-01
Needle trap devices (NTDs) have shown many advantages such as improved detection limits, reduced sampling time and volume, improved stability, and reproducibility if compared with other techniques used in breath analysis such as solid-phase extraction and solid-phase micro-extraction. Effects of sampling flow (2-30 ml/min) and volume (10-100 ml) were investigated in dry gas standards containing hydrocarbons, aldehydes, and aromatic compounds and in humid breath samples. NTDs contained (single-bed) polymer packing and (triple-bed) combinations of divinylbenzene/Carbopack X/Carboxen 1000. Substances were desorbed from the NTDs by means of thermal expansion and analyzed by gas chromatography-mass spectrometry. An automated CO2-controlled sampling device for direct alveolar sampling at the point-of-care was developed and tested in pilot experiments. Adsorption efficiency for small volatile organic compounds decreased and breakthrough increased when sampling was done with polymer needles from a water-saturated matrix (breath) instead from dry gas. Humidity did not affect analysis with triple-bed NTDs. These NTDs showed only small dependencies on sampling flow and low breakthrough from 1-5 %. The new sampling device was able to control crucial parameters such as sampling flow and volume. With triple-bed NTDs, substance amounts increased linearly with increasing sample volume when alveolar breath was pre-concentrated automatically. When compared with manual sampling, automatic sampling showed comparable or better results. Thorough control of sampling and adequate choice of adsorption material is mandatory for application of needle trap micro-extraction in vivo. The new CO2-controlled sampling device allows direct alveolar sampling at the point-of-care without the need of any additional sampling, storage, or pre-concentration steps.
Chemical Characterization of an Envelope B/D Sample from Hanford Tank 241-AZ-102
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hay, M.S.
2000-08-23
A sample from Hanford waste tank 241-AZ-102 was received at the Savannah River Technology Center (SRTC) and chemically characterized. The sample containing supernate and a small amount of sludge solids was analyzed as-received. The filtered supernatant liquid, the total dried solids of the sample, and the washed insoluble solids obtained from filtration of the sample were analyzed. A mass balance calculation of the three fractions of the sample analyzed indicate the analytical results appear relatively self-consistent for major components of the sample. However, some inconsistency was observed between results were more than one method of determination was employed and formore » species present in low concentrations. The actinides isotopes, plutonium, americium, and curium, present analytical challenges due to the low concentration of these species and the potential for introduction of small amounts of contamination during sampling handling resulting in large uncertainties. A direct comparison to previous analyses of material from tank 241-AZ-102 showed good agreement with the filtered supernatant liquid. However, the comparison of solids data showed poor agreement. The poor agreement shown between the current results for the solids samples and previous analyses most likely results from the uncertainties associated with obtaining small solids samples from a large non-homogenized waste tank.« less
Boucher, S E; Calsamiglia, S; Parsons, C M; Stein, H H; Stern, M D; Erickson, P S; Utterback, P L; Schwab, C G
2009-12-01
The objectives of this experiment were to measure intestinal digestibility of AA in the rumen-undegraded protein fraction (RUP-AA) of distillers dried grains with solubles (DDGS) and fish meal (FM) samples and to determine whether these feeds contain a constant protein fraction that is undegradable in the rumen and indigestible in the small intestine, as assumed in the French Institut National de la Recherche Agronomique (Paris, France) and Scandinavian AAT-PBV (AAT = AA absorbed from small intestine; PBV = protein balance in the rumen) models. Five sources of DDGS and 5 sources of FM were obtained from Feed Analysis Consortium, Inc. (Champaign, IL). To obtain the rumen-undegradable protein fraction, samples were ruminally incubated in situ for 16 h in 4 lactating cows, and the collected rumen-undegraded residues (RUR) were pooled by sample. Subsamples of the intact feeds and RUR were crop-intubated to 4 cecectomized roosters, and total excreta were collected for 48 h. Intact feeds, RUR, and excreta were analyzed for AA. Basal endogenous AA loss estimates were obtained from fasted birds and were used to calculate standardized digestibility of RUP-AA and AA in the intact feeds. Indigestibility coefficients of the intact feeds were calculated as (100 - % standardized AA digestibility), and indigestibility of the RUR was calculated as [(100 - % ruminal degradation of AA) x (100 - % standardized RUP-AA digestibility)/100]. Results indicate that standardized digestibility of feed-AA differs from RUP-AA for DDGS samples but not for FM samples, and that standardized digestibility of individual AA differs within samples. For the DDGS samples, standardized feed-AA and RUP-AA digestibility values were most often lowest for His and Lys and highest for Met and Trp. For FM samples, standardized feed-AA and RUP-AA digestibility values were most often lowest for His and highest for Trp. Results also indicate that DDGS and most FM samples do not contain a constant protein fraction that is both undegradable in the rumen and indigestible in the small intestine. Indigestibility values of RUR were lower than in intact feeds, suggesting that the feed ingredients used in this experiment contain a protein fraction that is indigestible in the intestine but partly degradable in the rumen or digestible in the intestine after rumen incubation, or both.
NASA Astrophysics Data System (ADS)
Hay, Michael B.; Myneni, Satish C. B.
2007-07-01
Carboxyls play an important role in the chemistry of natural organic molecules (NOM) in the environment, and their behavior is dependent on local structural environment within the macromolecule. We studied the structural environments of carboxyl groups in dissolved NOM from the Pine Barrens (New Jersey, USA), and IHSS NOM isolates from soils and river waters using attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy. It is well established that the energies of the asymmetric stretching vibrations of the carboxylate anion (COO -) are sensitive to the structural environment of the carboxyl group. These energies were compiled from previous infrared studies on small organic acids for a wide variety of carboxyl structural environments and compared with the carboxyl spectral features of the NOM samples. We found that the asymmetric stretching peaks for all NOM samples occur within a narrow range centered at 1578 cm -1, suggesting that all NOM samples examined primarily contain very similar carboxyl structures, independent of sample source and isolation techniques employed. The small aliphatic acids containing hydroxyl (e.g., D-lactate, gluconate), ether/ester (methoxyacetate, acetoxyacetate), and carboxylate (malonate) substitutions on the α-carbon, and the aromatic acids salicylate ( ortho-OH) and furancarboxylate ( O-heterocycle), exhibit strong overlap with the NOM range, indicating that similar structures may be common in NOM. The width of the asymmetric peak suggests that the structural heterogeneity among the predominant carboxyl configurations in NOM is small. Changes in peak area with pH at energies distant from the peak at 1578 cm -1, however, may be indicative of a small fraction of other aromatic carboxyls and aliphatic structures lacking α-substitution. This information is important in understanding NOM-metal and mineral-surface complexation, and in building appropriate structural and mechanistic models of humic materials.
An inexpensive and portable microvolumeter for rapid evaluation of biological samples.
Douglass, John K; Wcislo, William T
2010-08-01
We describe an improved microvolumeter (MVM) for rapidly measuring volumes of small biological samples, including live zooplankton, embryos, and small animals and organs. Portability and low cost make this instrument suitable for widespread use, including at remote field sites. Beginning with Archimedes' principle, which states that immersing an arbitrarily shaped sample in a fluid-filled container displaces an equivalent volume, we identified procedures that maximize measurement accuracy and repeatability across a broad range of absolute volumes. Crucial steps include matching the overall configuration to the size of the sample, using reflected light to monitor fluid levels precisely, and accounting for evaporation during measurements. The resulting precision is at least 100 times higher than in previous displacement-based methods. Volumes are obtained much faster than by traditional histological or confocal methods and without shrinkage artifacts due to fixation or dehydration. Calibrations using volume standards confirmed accurate measurements of volumes as small as 0.06 microL. We validated the feasibility of evaluating soft-tissue samples by comparing volumes of freshly dissected ant brains measured with the MVM and by confocal reconstruction.
Chlamydia and gonorrhoea contamination of clinic surfaces.
Lewis, Natasha; Dube, Gail; Carter, Christine; Pitt, Rachel; Alexander, Sarah; Ison, Catherine A; Harding, Jan; Brown, Louise; Fryer, John; Hodson, James; Ross, Jonathan
2012-10-01
Nucleic acid amplification tests, with their ability to detect very small amounts of nucleic acid, have become the principle diagnostic tests for Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (GC) in many sexual health clinics. The aim of this study was to investigate the extent of surface contamination with CT and GC within a city centre sexual health clinic and to evaluate the potential for contamination of containers used for the collection of self-taken swabs. Surface contamination with CT and GC was assessed by systematically sampling 154 different sites within one clinic using transcription-mediated amplification (TMA), quantitative PCR and culture. The caps of containers used by patients to collect self-taken samples were also tested for CT and GC using TMA. Of the 154 sites sampled, 20 (13.0%) tested positive on TMA. Of these, five (3.2%) were positive for CT alone, 11 (7.1%) for GC alone and four (2.6%) for both CT and GC. The proportion of GC TMA-positive test results differed by gender, with 11 (18.3%) positive results from the male patient clinic area compared with one (1.6%) from the female area (p=0.002). Positive samples were obtained from a variety of locations in the clinic, but the patient toilets were more likely to be contaminated than examination rooms (p=0.015). Quantitative PCR and culture assays were negative for all samples. 46 caps of the containers used for self-taken swabs were negative for both CT and GC on TMA testing. Surface contamination with chlamydial and gonococcal rRNA can occur within sexual health clinics, but the quantity of nucleic acid detected is low and infection risk to patients and staff is small. There remains a potential risk of contamination of patient samples leading to false-positive results.
Anomalous waveforms observed in laboratory-formed gas hydrate-bearing and ice-bearing sediments
Lee, Myung W.; Waite, William F.
2011-01-01
Acoustic transmission measurements of compressional, P, and shear, S, wave velocities rely on correctly identifying the P- and S-body wave arrivals in the measured waveform. In cylindrical samples for which the sample is much longer than the acoustic wavelength, these body waves can be obscured by high-amplitude waveform features arriving just after the relatively small-amplitude P-body wave. In this study, a normal mode approach is used to analyze this type of waveform, observed in sediment containing gas hydrate or ice. This analysis extends an existing normal-mode waveform propagation theory by including the effects of the confining medium surrounding the sample, and provides guidelines for estimating S-wave velocities from waveforms containing multiple large-amplitude arrivals. PMID:21476628
Boucher, S E; Calsamiglia, S; Parsons, C M; Stein, H H; Stern, M D; Erickson, P S; Utterback, P L; Schwab, C G
2009-09-01
The objectives of this experiment were to measure intestinal digestibility of AA in rumen undegradable protein (RUP-AA) in soybean meal (SBM) and expeller SBM (SoyPlus, West Central, Ralston, IA; SP) and to determine if these feeds contain a constant protein fraction that is undegradable in the rumen and indigestible in the small intestine, as assumed in the French Institut National de la Recherche Agronomique (Paris, France) and Scandinavian AAT-PBV (AAT = AA absorbed from small intestine; PBV = protein balance in the rumen) models. Three samples of SBM and 3 samples of SP were obtained from the Feed Analysis Consortium Inc. (Savoy, IL). To obtain the RUP fraction, samples were ruminally incubated in situ for 16 h in 4 lactating cows, and the collected rumen undegraded residues (RUR) were pooled by sample. Subsamples of the intact feeds and RUR were crop intubated to 4 cecectomized roosters, and total excreta were collected for 48 h. Intact feeds, RUR, and excreta were analyzed for AA. Basal endogenous AA loss estimates were obtained from fasted birds and were used to calculate standardized digestibility of AA in the intact feeds and RUP-AA. Indigestibility coefficients of the intact feeds were calculated as (100 - % standardized AA digestibility), and indigestibility of the RUR was calculated as [(100 - % ruminal degradation of AA) x [(100 - % standardized RUP-AA digestibility)]/100]. Results indicated that standardized digestibility of feed-AA was similar to standardized digestibility of RUP-AA for SBM and SP samples and that standardized digestibility of individual AA differed within samples. Standardized feed-AA and RUP-AA digestibility values were lowest for Lys and Cys and highest for Trp and Met. Results also indicated that SBM and SP did not contain a constant protein fraction that was both undegradable in the rumen and indigestible in the small intestine. Indigestibility values of RUR were lower than in intact feeds, suggesting that SBM and SP contain a protein fraction that is indigestible in the intestine but partly degradable in the rumen, digestible in the intestine after ruminal incubation, or both.
Doherty, Brenda; Csáki, Andrea; Thiele, Matthias; Zeisberger, Matthias; Schwuchow, Anka; Kobelke, Jens; Fritzsche, Wolfgang; Schmidt, Markus A
2017-02-01
Detecting small quantities of specific target molecules is of major importance within bioanalytics for efficient disease diagnostics. One promising sensing approach relies on combining plasmonically-active waveguides with microfluidics yielding an easy-to-use sensing platform. Here we introduce suspended-core fibres containing immobilised plasmonic nanoparticles surrounding the guiding core as a concept for an entirely integrated optofluidic platform for efficient refractive index sensing. Due to the extremely small optical core and the large adjacent microfluidic channels, over two orders of magnitude of nanoparticle coverage densities have been accessed with millimetre-long sample lengths showing refractive index sensitivities of 170 nm/RIU for aqueous analytes where the fibre interior is functionalised by gold nanospheres. Our concept represents a fully integrated optofluidic sensing system demanding small sample volumes and allowing for real-time analyte monitoring, both of which are highly relevant within invasive bioanalytics, particularly within molecular disease diagnostics and environmental science.
Aitken, C G
1999-07-01
It is thought that, in a consignment of discrete units, a certain proportion of the units contain illegal material. A sample of the consignment is to be inspected. Various methods for the determination of the sample size are compared. The consignment will be considered as a random sample from some super-population of units, a certain proportion of which contain drugs. For large consignments, a probability distribution, known as the beta distribution, for the proportion of the consignment which contains illegal material is obtained. This distribution is based on prior beliefs about the proportion. Under certain specific conditions the beta distribution gives the same numerical results as an approach based on the binomial distribution. The binomial distribution provides a probability for the number of units in a sample which contain illegal material, conditional on knowing the proportion of the consignment which contains illegal material. This is in contrast to the beta distribution which provides probabilities for the proportion of a consignment which contains illegal material, conditional on knowing the number of units in the sample which contain illegal material. The interpretation when the beta distribution is used is much more intuitively satisfactory. It is also much more flexible in its ability to cater for prior beliefs which may vary given the different circumstances of different crimes. For small consignments, a distribution, known as the beta-binomial distribution, for the number of units in the consignment which are found to contain illegal material, is obtained, based on prior beliefs about the number of units in the consignment which are thought to contain illegal material. As with the beta and binomial distributions for large samples, it is shown that, in certain specific conditions, the beta-binomial and hypergeometric distributions give the same numerical results. However, the beta-binomial distribution, as with the beta distribution, has a more intuitively satisfactory interpretation and greater flexibility. The beta and the beta-binomial distributions provide methods for the determination of the minimum sample size to be taken from a consignment in order to satisfy a certain criterion. The criterion requires the specification of a proportion and a probability.
Khoshkava, Vahid; Kamal, Musa R
2014-06-11
Polypropylene (PP) nanocomposites containing spray-dried cellulose nanocrystals (CNC), freeze-dried CNC, and spray-freeze-dried CNC (CNCSFD) were prepared via melt mixing in an internal batch mixer. Polarized light, scanning electron, and atomic force microscopy showed significantly better dispersion of CNCSFD in PP/CNC nanocomposites compared with the spray-dried and freeze-dried CNCs. Rheological measurements, including linear and nonlinear viscoelastic tests, were performed on PP/CNC samples. The microscopy results were supported by small-amplitude oscillatory shear tests, which showed substantial rises in the magnitudes of key rheological parameters of PP samples containing CNCSFD. Steady-shear results revealed a strong shear thinning behavior of PP samples containing CNCSFD. Moreover, PP melts containing CNCSFD exhibited a yield stress. The magnitude of the yield stress and the degree of shear thinning behavior increased with CNCSFD concentration. It was found that CNCSFD agglomerates with a weblike structure were more effective in modifying the rheological properties. This effect was attributed to better dispersion of the agglomerates with the weblike structure. Dynamic mechanical analysis showed considerable improvement in the modulus of samples containing CNCSFD agglomerates. The percolation mechanical model with modified volume percolation threshold and filler network strength values and the Halpin-Kardos model were used to fit the experimental results.
Experiments with a small behaviour controlled planetary rover
NASA Technical Reports Server (NTRS)
Miller, David P.; Desai, Rajiv S.; Gat, Erann; Ivlev, Robert; Loch, John
1993-01-01
A series of experiments that were performed on the Rocky 3 robot is described. Rocky 3 is a small autonomous rover capable of navigating through rough outdoor terrain to a predesignated area, searching that area for soft soil, acquiring a soil sample, and depositing the sample in a container at its home base. The robot is programmed according to a reactive behavior control paradigm using the ALFA programming language. This style of programming produces robust autonomous performance while requiring significantly less computational resources than more traditional mobile robot control systems. The code for Rocky 3 runs on an eight bit processor and uses about ten k of memory.
Dynamic rheology of food protein networks
USDA-ARS?s Scientific Manuscript database
Small amplitude oscillatory shear analyses of samples containing protein are useful for determining the nature of the protein matrix without damaging it. Elastic modulus, viscous modulus, and loss tangent (the ratio of viscous modulus to elastic modulus) give information on the strength of the netw...
Dynamic rheology of food protein networks
USDA-ARS?s Scientific Manuscript database
Small amplitude oscillatory shear analyses (SAOSA) of samples containing protein are useful for determining the nature of the protein matrix without damaging it. The Dairy Processing and Products Research Unit of the Agricultural Research Service, USDA has pioneered the use of SAOSA in understandin...
NASA Technical Reports Server (NTRS)
Seidel, D. A.; Batina, J. T.
1986-01-01
The development, use and operation of the XTRAN2L program that solves the two dimensional unsteady transonic small disturbance potential equation are described. The XTRAN2L program is used to calculate steady and unsteady transonic flow fields about airfoils and is capable of performing self contained transonic flutter calculations. Operation of the XTRAN2L code is described, and tables defining all input variables, including default values, are presented. Sample cases that use various program options are shown to illustrate operation of XTRAN2L. Computer listings containing input and selected output are included as an aid to the user.
Polonium-210 analyses of vegetables, cured and uncured tobacco, and associated soils.
Berger, K C; Erhardt, W H; Francis, C W
1965-12-24
Analysis of the edible portion of vegetables and samples of green leaf tobacco failed to show polonium-210. The cured samples of leaf tobacco and the soils that were analyzed all contained small quantities of the element. Muck soils contained three times as much Po(210) as did mineral soils. Solutions used commonly to extract "available" forms of many mineral elements failed to extract a detectable amount of Po(2l0). Indications are that Po(210) or its radioactive precursors are not taken up from the soil directly by plant roots but rather by sorption in dead, moist plant materials at the atmosphere-plant interface.
Improving the analysis of composite endpoints in rare disease trials.
McMenamin, Martina; Berglind, Anna; Wason, James M S
2018-05-22
Composite endpoints are recommended in rare diseases to increase power and/or to sufficiently capture complexity. Often, they are in the form of responder indices which contain a mixture of continuous and binary components. Analyses of these outcomes typically treat them as binary, thus only using the dichotomisations of continuous components. The augmented binary method offers a more efficient alternative and is therefore especially useful for rare diseases. Previous work has indicated the method may have poorer statistical properties when the sample size is small. Here we investigate small sample properties and implement small sample corrections. We re-sample from a previous trial with sample sizes varying from 30 to 80. We apply the standard binary and augmented binary methods and determine the power, type I error rate, coverage and average confidence interval width for each of the estimators. We implement Firth's adjustment for the binary component models and a small sample variance correction for the generalized estimating equations, applying the small sample adjusted methods to each sub-sample as before for comparison. For the log-odds treatment effect the power of the augmented binary method is 20-55% compared to 12-20% for the standard binary method. Both methods have approximately nominal type I error rates. The difference in response probabilities exhibit similar power but both unadjusted methods demonstrate type I error rates of 6-8%. The small sample corrected methods have approximately nominal type I error rates. On both scales, the reduction in average confidence interval width when using the adjusted augmented binary method is 17-18%. This is equivalent to requiring a 32% smaller sample size to achieve the same statistical power. The augmented binary method with small sample corrections provides a substantial improvement for rare disease trials using composite endpoints. We recommend the use of the method for the primary analysis in relevant rare disease trials. We emphasise that the method should be used alongside other efforts in improving the quality of evidence generated from rare disease trials rather than replace them.
Nordin, Carl F.; Meade, R.H.; Curtis, W.F.; Bosio, N.J.; Delaney, B.M.
1979-01-01
One-hundred-eight samples of bed material were collected from the Amazon River and its major tributaries between Belem, Brazil , and Iquitos, Peru. Samples were taken with a standard BM-54 sampler or with pipe dredges from May 18 to June 5, 1977. Most of the samples have median diameters in the size range of fine to medium sand and contain small percentages of fine gravel. Complete size distributions are tabulated. (Woodard-USGS)
Nordin, Carl F.; Meade, R.H.; Mahoney, H.A.; Delany, B.M.
1977-01-01
Sixty-five samples of bed material were collected from the Amazon River and its major tributaries between Belem, Brazil, and Iquitos, Peru. Samples were taken with a standard BM-54 sampler, a pipe dredge, or a Helley-Smith bedload sampler. Most of the samples have median diameters in the size range of fine to medium sand and contain small percentages of fine gravel. Complete size distributions are tabulated.
Inertial impaction air sampling device
Dewhurst, Katharine H.
1990-01-01
An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry.
Inertial impaction air sampling device
Dewhurst, K.H.
1987-12-10
An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.
The IGF1 small dog haplotype is derived from Middle Eastern grey wolves.
Gray, Melissa M; Sutter, Nathan B; Ostrander, Elaine A; Wayne, Robert K
2010-02-24
A selective sweep containing the insulin-like growth factor 1 (IGF1) gene is associated with size variation in domestic dogs. Intron 2 of IGF1 contains a SINE element and single nucleotide polymorphism (SNP) found in all small dog breeds that is almost entirely absent from large breeds. In this study, we surveyed a large sample of grey wolf populations to better understand the ancestral pattern of variation at IGF1 with a particular focus on the distribution of the small dog haplotype and its relationship to the origin of the dog. We present DNA sequence data that confirms the absence of the derived small SNP allele in the intron 2 region of IGF1 in a large sample of grey wolves and further establishes the absence of a small dog associated SINE element in all wild canids and most large dog breeds. Grey wolf haplotypes from the Middle East have higher nucleotide diversity suggesting an origin there. Additionally, PCA and phylogenetic analyses suggests a closer kinship of the small domestic dog IGF1 haplotype with those from Middle Eastern grey wolves. The absence of both the SINE element and SNP allele in grey wolves suggests that the mutation for small body size post-dates the domestication of dogs. However, because all small dogs possess these diagnostic mutations, the mutations likely arose early in the history of domestic dogs. Our results show that the small dog haplotype is closely related to those in Middle Eastern wolves and is consistent with an ancient origin of the small dog haplotype there. Thus, in concordance with past archeological studies, our molecular analysis is consistent with the early evolution of small size in dogs from the Middle East.See associated opinion by Driscoll and Macdonald: http://jbiol.com/content/9/2/10.
The Observational Determination of the Age of the Universe as a Laboratory Exercise.
ERIC Educational Resources Information Center
Cadmus, Robert R., Jr.
1999-01-01
Describes a procedure that allows undergraduate students to determine the approximate age of the universe using their own data. The experiment requires a relatively small telescope with a modest spectrograph. Includes sample data and calculations. (Contains 11 references.) (Author/WRM)
Light chain typing of immunoglobulins in small samples of biological material
Rádl, J.
1970-01-01
A method is described for the typing of the light chains of immunoglobulins in small samples of sera or external secretions and without their previous isolation. It consists of immunoelectrophoresis in agar plates which contain specific antisera against one of the light chain types. All immunoglobulins of this type are thus selected by precipitation in the central area during the electrophoretic phase. Immunoglobulins of the opposite light chain type diffuse through the agar and react with the class specific antisera from the troughs. This results in the precipitin lines as in conventional immunoelectrophoresis. This technique has proved most useful for typing heterogenous or homogeneous immunoglobulins in normal and low concentration. The antisera used for incorporation in the agar should fulfil special requirements. They should contain a high level of antibodies against common surface determinants of the immunoglobulin light chains. The further possibilities of this immunoselection technique for typing different protein mixtures is discussed. ImagesFIG. 1FIG. 2FIG. 3FIG. 4FIG. 5FIG. 6 PMID:4098592
Ionita, Mariana; Howe, Daniel K; Lyons, Eugene T; Tolliver, Sharon C; Kaplan, Ray M; Mitrea, Ioan Liviu; Yeargan, Michelle
2010-03-25
A sensitive and specific PCR hybridization assay was applied for species-specific monitoring of the small strongyle (Strongylida: Cyathostominae) populations in horses in a herd before and after treatment with the anthelmintic drug ivermectin. Fecal samples were collected pre- and post-treatment weekly from eight individual horses (four foals and four yearlings) for 6 weeks to determine counts of strongyle eggs per gram of feces (EPGs). Additionally, one foal and one yearling were nontreated controls. Also, one horse, from another herd known to be infected with Strongylus spp., was a positive control for these parasites. Genomic DNA was obtained from eggs in groups of approximately 6000-7000 eggs except for two samples containing low EPGs in which 450 eggs were used. Amplification of the intergenic spacers (IGSs) of ribosomal DNA (rDNA) of small and large strongyles followed by reverse line blot (RLB) assay were performed to identify the presence of the 12 most common equine small strongyle species and to discriminate them from Strongylus spp. Overall, 11 small strongyle species were identified in pretreatment samples. In the samples collected at 4 weeks after ivermectin treatment, eight small strongyle species were identified and four of them were predominant (Cylicocyclus nassatus, Cylicostephanus longibursatus, Cylicostephanus calicatus and Cylicostephanus minutus). At 5 and 6 weeks post-treatment, the RLB assay analysis showed almost the same composition in the small strongyle population as before treatment. Strongylus spp. were identified only in samples collected from the positive control horse for these parasites. These data confirm the ability of the PCR-RLB technique for simultaneous species-specific differentiation of equine strongyle eggs, indicating a valuable way of furthering drug-resistance studies.
Anomalous waveforms observed in laboratory-formed gas hydrate-bearing and ice-bearing sediments
Lee, M.W.; Waite, W.F.
2011-01-01
Acoustic transmission measurements of compressional, P, and shear, S, wave velocities rely on correctly identifying the P- and S-body wave arrivals in the measured waveform. In cylindrical samples for which the sample is much longer than the acoustic wavelength, these body waves can be obscured by high-amplitude waveform features arriving just after the relatively small-amplitude P-body wave. In this study, a normal mode approach is used to analyze this type of waveform, observed in sediment containing gas hydrate or ice. This analysis extends an existing normal-mode waveform propagation theory by including the effects of the confining medium surrounding the sample, and provides guidelines for estimating S-wave velocities from waveforms containing multiple large-amplitude arrivals. ?? 2011 Acoustical Society of America.
Waage, Astrid S.; Vardund, Traute; Lund, Vidar; Kapperud, Georg
1999-01-01
A rapid and sensitive assay was developed for detection of small numbers of Campylobacter jejuni and Campylobacter coli cells in environmental water, sewage, and food samples. Water and sewage samples were filtered, and the filters were enriched overnight in a nonselective medium. The enrichment cultures were prepared for PCR by a rapid and simple procedure consisting of centrifugation, proteinase K treatment, and boiling. A seminested PCR based on specific amplification of the intergenic sequence between the two Campylobacter flagellin genes, flaA and flaB, was performed, and the PCR products were visualized by agarose gel electrophoresis. The assay allowed us to detect 3 to 15 CFU of C. jejuni per 100 ml in water samples containing a background flora consisting of up to 8,700 heterotrophic organisms per ml and 10,000 CFU of coliform bacteria per 100 ml. Dilution of the enriched cultures 1:10 with sterile broth prior to the PCR was sometimes necessary to obtain positive results. The assay was also conducted with food samples analyzed with or without overnight enrichment. As few as ≤3 CFU per g of food could be detected with samples subjected to overnight enrichment, while variable results were obtained for samples analyzed without prior enrichment. This rapid and sensitive nested PCR assay provides a useful tool for specific detection of C. jejuni or C. coli in drinking water, as well as environmental water, sewage, and food samples containing high levels of background organisms. PMID:10103261
Xu, Jiao; Li, Mei; Shi, Guoliang; Wang, Haiting; Ma, Xian; Wu, Jianhui; Shi, Xurong; Feng, Yinchang
2017-11-15
In this study, single particle mass spectra signatures of both coal burning boiler and biomass burning boiler emitted particles were studied. Particle samples were suspended in clean Resuspension Chamber, and analyzed by ELPI and SPAMS simultaneously. The size distribution of BBB (biomass burning boiler sample) and CBB (coal burning boiler sample) are different, as BBB peaks at smaller size, and CBB peaks at larger size. Mass spectra signatures of two samples were studied by analyzing the average mass spectrum of each particle cluster extracted by ART-2a in different size ranges. In conclusion, BBB sample mostly consists of OC and EC containing particles, and a small fraction of K-rich particles in the size range of 0.2-0.5μm. In 0.5-1.0μm, BBB sample consists of EC, OC, K-rich and Al_Silicate containing particles; CBB sample consists of EC, ECOC containing particles, while Al_Silicate (including Al_Ca_Ti_Silicate, Al_Ti_Silicate, Al_Silicate) containing particles got higher fractions as size increase. The similarity of single particle mass spectrum signatures between two samples were studied by analyzing the dot product, results indicated that part of the single particle mass spectra of two samples in the same size range are similar, which bring challenge to the future source apportionment activity by using single particle aerosol mass spectrometer. Results of this study will provide physicochemical information of important sources which contribute to particle pollution, and will support source apportionment activities. Copyright © 2017. Published by Elsevier B.V.
Electron paramagnetic resonance of a 10B-containing heterocyclic radical
NASA Astrophysics Data System (ADS)
Eaton, Sandra S.; Ngendahimana, Thacien; Eaton, Gareth R.; Jupp, Andrew R.; Stephan, Douglas W.
2018-05-01
Electron paramagnetic resonance measurements for a 10B-containing heterocyclic phenanthrenedione radical, (C6F5)2B(O2C14H8), were made at X-band in 9:1 toluene:dichloromethane from 10 to 293 K and in toluene from 180 to 293 K. In well-deoxygenated 0.1 mM toluene solution at room temperature hyperfine couplings to 10B, four pairs of protons and five pairs of fluorines contribute to a continuous wave spectrum with many resolved lines. Hyperfine couplings were adjusted to provide the best fit for spectra of the radical enriched in 10B and the analogous radical synthesized with 10,11B in natural abundance, resulting in small refinements of the hyperfine coupling constants previously reported for the natural abundance sample. Electron spin relaxation rates at temperatures between 15 and 293 K were similar for samples containing 10B and natural isotope abundance. Analysis of electron spin echo envelope modulation and hyperfine correlation spectroscopy data at 80 K found Axx = -7.5 ± 0.3, Ayy = -8.5 ± 0.3, and Azz = -10.8 ± 0.3 MHz for 11B, which indicates small spin density on the boron. The spin echo and hyperfine spectroscopy data for the 10B -containing radical are consistent with the factor of 2.99 smaller hyperfine values for 10B than for 11B.
Rodeles, Amaia A.; Galicia, David; Miranda, Rafael
2016-01-01
The study of freshwater fish species biodiversity and community composition is essential for understanding river systems, the effects of human activities on rivers, and the changes these animals face. Conducting this type of research requires quantitative information on fish abundance, ideally with long-term series and fish body measurements. This Data Descriptor presents a collection of 12 datasets containing a total of 146,342 occurrence records of 41 freshwater fish species sampled in 233 localities of various Iberian river basins. The datasets also contain 148,749 measurement records (length and weight) for these fish. Data were collected in different sampling campaigns (from 1992 to 2015). Eleven datasets represent large projects conducted over several years, and another combines small sampling campaigns. The Iberian Peninsula contains high fish biodiversity, with numerous endemic species threatened by various menaces, such as water extraction and invasive species. These data may support the development of large biodiversity conservation studies. PMID:27727236
Rodeles, Amaia A; Galicia, David; Miranda, Rafael
2016-10-11
The study of freshwater fish species biodiversity and community composition is essential for understanding river systems, the effects of human activities on rivers, and the changes these animals face. Conducting this type of research requires quantitative information on fish abundance, ideally with long-term series and fish body measurements. This Data Descriptor presents a collection of 12 datasets containing a total of 146,342 occurrence records of 41 freshwater fish species sampled in 233 localities of various Iberian river basins. The datasets also contain 148,749 measurement records (length and weight) for these fish. Data were collected in different sampling campaigns (from 1992 to 2015). Eleven datasets represent large projects conducted over several years, and another combines small sampling campaigns. The Iberian Peninsula contains high fish biodiversity, with numerous endemic species threatened by various menaces, such as water extraction and invasive species. These data may support the development of large biodiversity conservation studies.
Portable x-ray fluorescence spectrometer for environmental monitoring of inorganic pollutants
NASA Technical Reports Server (NTRS)
Clark, III, Benton C. (Inventor); Thornton, Michael G. (Inventor)
1991-01-01
A portable x-ray fluorescence spectrometer has a portable sensor unit containing a battery, a high voltage power supply, an x-ray tube which produces a beam x-ray radiation directed toward a target sample, and a detector for fluorescent x-rays produced by the sample. If a silicon-lithium detector is used, the sensor unit also contains either a thermoelectric or thermochemical cooler, or a small dewar flask containing liquid nitrogen to cool the detector. A pulse height analyzer (PHA) generates a spectrum of data for each sample consisting of the number of fluorescent x-rays detected as a function of their energy level. The PHA can also store spectrum data for a number of samples in the field. A processing unit can be attached to the pulse height analyzer to upload and analyze the stored spectrum data for each sample. The processing unit provides a graphic display of the spectrum data for each sample, and provides qualitative and/or quantitative analysis of the elemental composition of the sample by comparing the peaks in the sample spectrum against known x-ray energies for various chemical elements. An optional filtration enclosure can be used to filter particles from a sample suspension, either in the form of a natural suspension or a chemically created precipitate. The sensor unit is then temporarily attached to the filtration unit to analyze the particles collected by the filter medium.
Winkelman, D.L.; Van Den Avyle, M.J.
2002-01-01
The objective of this study was to determine dietary overlap between blueback herring and threadfin shad in J. Strom Thrumond Reservoir, South Carolina/Georgia. We also evaluated prey selectivity for each speices and diet differences between two size categories of blueback herring. Diet and zooplankton samples were collected every other month from April 1992 to February 1994. We examined stomachs containing prey from 170 large blueback herring (>140mm), 96 small blueback herring (<140mm), and 109 threadfin shad, and we also examined 45 zooplankton samples. Large blueback herring diets differed significantly from threadfin shad diets on 11 of 12 sampling dates, and small blueback herring diets differed from threadfin shad diets on all sampling dates. In general, blueback herring consumed proportionally more copepods and fewer Bosmina sp. and rotifers than threadfin shad. Large and small blueback herring diets were significantly different on five of eight sampling dates, primarily due to the tendency of small blueback herring to eat proportionally more Bosmina sp. than large blueback herring. Both blueback herring and threadfin shad fed selectively during some periods of the year. Diet differences between the species may contribute to their coexistence; however, both blueback herring and threadfin shad showed a strong preference for Bosmina sp., increasing the chance that they may negatively influence one another.
Mairinger, Fabian D; Walter, Robert Fh; Vollbrecht, Claudia; Hager, Thomas; Worm, Karl; Ting, Saskia; Wohlschläger, Jeremias; Zarogoulidis, Paul; Zarogoulidis, Konstantinos; Schmid, Kurt W
2014-01-01
Isothermal multiple displacement amplification (IMDA) can be a powerful tool in molecular routine diagnostics for homogeneous and sequence-independent whole-genome amplification of notably small tumor samples, eg, microcarcinomas and biopsies containing a small amount of tumor. Currently, this method is not well established in pathology laboratories. We designed a study to confirm the feasibility and convenience of this method for routine diagnostics with formalin-fixed, paraffin-embedded samples prepared by laser-capture microdissection. A total of 250 μg DNA (concentration 5 μg/μL) was generated by amplification over a period of 8 hours with a material input of approximately 25 cells, approximately equivalent to 175 pg of genomic DNA. In the generated DNA, a representation of all chromosomes could be shown and the presence of elected genes relevant for diagnosis in clinical samples could be proven. Mutational analysis of clinical samples could be performed without any difficulty and showed concordance with earlier diagnostic findings. We established the feasibility and convenience of IMDA for routine diagnostics. We also showed that small amounts of DNA, which were not analyzable with current molecular methods, could be sufficient for a wide field of applications in molecular routine diagnostics when they are preamplified with IMDA.
Factors influencing moisture analysis in the 3013 destructive examination surveillance program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scogin, J. H.
Thermogravimetric analysis of a solid sample with mass spectrometry (TGA-MS) of the evolved gas is used in the destructive examination (DE) portion of the Integrated Surveillance Program to quantify the moisture content of the material stored in a 3013 container. As with any measurement determined from a small sample, the collection, storage, transportation, and handling of the sample can affect its ability to represent the properties of the bulk material. During the course of the DE program, questions have periodically arisen concerning the ability of the moisture sample to reflect reliably the actual moisture content of the entire material storedmore » in the 3013 container. Most concerns are related to the ability to collect a representative sample and to preserve the moisture content of the sample between collection and analysis. Recent delays in analysis caused by maintenance issues with the TGA-MS instrument presented a unique opportunity to document and quantify the effects various factors have on the TGA-MS moisture measurement. This report will use recent data to document the effects that current sample collection and handling practices have on the TGA-MS moisture measurement. Some suggestions will be made which could improve the current sample collection and handling practices for the TGA-MS moisture measurement so that the analytical results more accurately reflect the moisture content of the material stored in the 3013 container.« less
Inertial impaction air sampling device
Dewhurst, K.H.
1990-05-22
An inertial impactor is designed which is to be used in an air sampling device for collection of respirable size particles in ambient air. The device may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.
Reactivity of stratospheric aerosols to small amounts of ammonia in the laboratory environment
NASA Technical Reports Server (NTRS)
Hayes, D.; Snetsinger, K.; Ferry, G.; Oberbeck, V.; Farlow, N.
1980-01-01
Trace ammonia in laboratory air reacts easily with sulfuric acid aerosol samples to form crystalline ammonium sulfate. Argon atmospheres, however, protect sampling surfaces from ammonia contamination. It is found that atmospheric aerosols treated in this way contain only sulfuric acid. After an hour exposed to laboratory air, these same samples convert to ammonium sulfate. Aerosol particles have been collected, using argon control, to determine if the absence of crystalline sulfate is common. But so far there is no evidence that aerosols are neutralized by ammonia in the stratosphere.
CO₂ adsorption on amine-functionalized periodic mesoporous benzenesilicas.
Sim, Kyohyun; Lee, Nakwon; Kim, Joonseok; Cho, Eun-Bum; Gunathilake, Chamila; Jaroniec, Mietek
2015-04-01
CO2 adsorption was investigated on amine-functionalized mesoporous silica (SBA-15) and periodic mesoporous organosilica (PMO) samples. Hexagonally (p6mm) ordered mesoporous SBA-15 and benzene-PMO (BPMO) samples were prepared in the presence of Pluronic P123 block copolymer template under acidic conditions. Three kinds of amine-containing organosilanes and polyethylenimine were used to functionalize SBA-15 and BPMO. Small-angle X-ray scattering and nitrogen adsorption isotherms showed that these samples featured ordered mesostructure, high surface area, and narrow pore size distributions. Solid-state (13)C- and (29)Si cross-polarization magic-angle spinning NMR spectra showed chemical linkage between amine-containing modifiers and the surface of mesoporous materials. The chemically linked amine-containing modifiers were found to be on both the inner and outer surfaces. N-[3-(trimethoxysilyl)propyl]ethylenediamine-modified BPMO (A2-BPMO) sample exhibited the highest CO2 uptake (i.e., ∼3.03 mmol/g measured on a volumetric adsorption analyzer) and the fastest adsorption rate (i.e., ∼13 min to attain 90% of the maximum amount) among all the samples studied. Selectivity and reproducibility measurements for the A2-BPMO sample showed quite good performance in flowing N2 gas at 40 mL/min and CO2 gas of 60 mL/min at 25 °C.
Technical note: Headspace analysis of explosive compounds using a novel sampling chamber.
DeGreeff, Lauryn; Rogers, Duane A; Katilie, Christopher; Johnson, Kevin; Rose-Pehrsson, Susan
2015-03-01
The development of instruments and methods for explosive vapor detection is a continually evolving field of interest. A thorough understanding of the characteristic vapor signatures of explosive material is imperative for the development and testing of new and current detectors. In this research a headspace sampling chamber was designed to contain explosive materials for the controlled, reproducible sampling and characterization of vapors associated with these materials. In a detonation test, the chamber was shown to contain an explosion equivalent to three grams of trinitrotoluene (TNT) without damage to the chamber. The efficacy of the chamber in controlled headspace sampling was evaluated in laboratory tests with bulk explosive materials. Small quantities of TNT, triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD) were separately placed in the sampling chamber, and the headspace of each material was analyzed by gas chromatography/mass spectrometry (GC/MS) with online cryogenic trapping to yield characteristic vapor signatures for each explosive compound. Chamber sampling conditions, temperature and sampling time, were varied to demonstrate suitability for precise headspace analysis. Published by Elsevier Ireland Ltd.
NASA Astrophysics Data System (ADS)
Wiedemann-Bidlack, F. B.; Colman, A. S.; Fogel, M. L.
2003-12-01
Oxygen isotope analyses in bone and teeth of living and fossil animals are widely used for testing hypotheses about variability of diet and habitat. For the analysis of environmental or dietary changes in the past, tooth enamel has become the preferred study material, because its mineral content is higher than bone and dentine, and the relatively large size of the carbonato-apatite crystals of enamel make it more stable against post mortem diagenetic alteration than dentine or bone. Intra-tooth sampling of dental enamel is increasingly used for the investigation of seasonal climate variability, taking advantage of both the high correlation between an animal's drinking water and the δ 18O in its mineralized tissues and the incremental growth pattern of tooth enamel. The different oxygen-containing ions of bioapatite (phosphate, carbonate, and hydroxyl group) incorporate into the mineral lattice at different rates during enamel mineralization, and differ in their susceptibility against post mortem diagenetic alteration. In addition, it is difficult to account for the different reaction chemistries of phosphate, carbonate, and hydroxyl group using isotope analysis techniques that include all oxygen contained in the enamel (e.g., laser ablation). These problems can be addressed analyzing phosphate oxygen only. However, two major factors limit the potential of δ 18O analyses in dental enamel: A) the starting sample size for isotope analyzes often precludes the use of small teeth or the intra-tooth sampling of a given tooth; B) Small amounts of biogenic organic material in tooth enamel (less than 1% by wt) can reduce the precision and lead to anomalous analytical results in δ 18O measurements on Ag3PO4 produced from tooth enamel. A new procedure was developed for the pre-treatment and δ 18O analysis of phosphate from small samples (500 μ g) of tooth enamel containing organic matter. Ag3PO{4} was precipitated quantitatively for analysis of δ 18Ophosphate using a Thermoquest-Finnigan TC/EA coupled to Delta Plus XL. A sodium hypochlorite sample pre-treatment step was determined to remove organic matter quantitatively without altering the isotopic composition of the phosphate oxygen. The reproducibility of δ 18O values for pretreated samples (0.2-0.3 ‰ , 1σ ) is much better than for samples without pre-treatment (1.2 ‰ , 1σ ). Phosphate oxygen isotope standards processed using this technique gave measured values indistinguishable from the standard composition, demonstrating the accuracy of the new technique.
Antibacterial performance of nano polypropylene filter media containing nano-TiO2 and clay particles
NASA Astrophysics Data System (ADS)
Shafiee, Sara; Zarrebini, Mohammad; Naghashzargar, Elham; Semnani, Dariush
2015-10-01
Disinfection and elimination of pathogenic microorganisms from liquid can be achieved by filtration process using antibacterial filter media. The advent of nanotechnology has facilitated the introduction of membranes consisting of nano-fiber in filtration operations. The melt electro-spun fibers due to their extremely small diameters are used in the production of this particular filtration medium. In this work, antibacterial polypropylene filter medium containing clay particles and nano-TiO2 were made using melt electro-spun technology. Antibacterial performance of polypropylene nano-filters was evaluated using E. coli bacteria. Additionally, filtration efficiency of the samples in terms fiber diameter, filter porosity, and fiber distribution using image processing technique was determined. Air permeability and dust aerosol tests were conducted to establish the suitability of the samples as a filter medium. It was concluded that as far as antibacterial property is concerned, nano-fibers filter media containing clay particles are preferential to similar media containing TiO2 nanoparticles.
Demirhan, Yasemin; Ulca, Pelin; Senyuva, Hamide Z
2012-03-01
A commercially available real-time PCR, based on a multi-copy target cytochrome b (cyt b) using porcine specific primers, has been validated for the Halal/Kosher authentication of gelatine. Extraction and purification of DNA from gelatine were successfully achieved using the SureFood® PREP Animal system, and real-time PCR was carried out using SureFood® Animal ID Pork Sens kit. The minimum level of adulteration that could be detected was 1.0% w/w for marshmallows and gum drops. A small survey was undertaken of processed food products such as gum drops, marshmallows and Turkish delight, believed to contain gelatine. Of fourteen food products from Germany, two samples were found to contain porcine gelatine, whereas of twenty-nine samples from Turkey twenty-eight were negative. However, one product from Turkey contained porcine DNA and thus was not Halal, and neither was the use of porcine gelatine indicated on the product label. Copyright © 2011 Elsevier Ltd. All rights reserved.
Ryals, John; Lawton, Kay; Stevens, Daniel; Milburn, Michael
2007-07-01
Metabolon is an emerging technology company developing proprietary analytical methods and software for biomarker discovery using metabolomics. The company's aim is to measure all small molecules (<1500 Da) in a biological sample. These small-molecule compounds include biochemicals of cellular metabolism and xenobiotics from diet and environment. Our proprietary mLIMStrade mark system contains advanced metabolomic software and automated data-processing tools that use a variety of data-analysis and quality-control algorithms to convert raw mass-spectrometry data to identified, quantitated compounds. Metabolon's primary focus is a fee-for-service business that exploits this technology for pharmaceutical and biotechnology companies, with additional clients in the consumer goods, cosmetics and agricultural industries. Fee-for-service studies are often collaborations with groups that employ a variety of technologies for biomarker discovery. Metabolon's goal is to develop technology that will automatically analyze any sample for the small-molecule components present and become a standard technology for applications in health and related sciences.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgan, T.L.; George, W.E.; Hensley, W.K.
As part of the Hydrogeochemical and Stream Sediment Reconnaissance (HSSR) of the National Uranium Resource Evaluation (NURE) sponsored by the US Department of Energy (DOE), the Los Alamos Scientific Laboratory (LASL) conducted a detailed hydrogeochemical survey of well waters in a 4250-km/sup 2/ area near Pie Town in west-central New Mexico. A total of 300 well samples was collected and analyzed for uranium and 23 other elements. The results of these analyses and carbonate and bicarbonate ion concentrations are presented in the Appendixes of this report. Uranium concentrations range from below the detection limit of 0.02 parts per billion (ppB)more » to 293.18 ppB and average 8.71 ppB. Samples containing high levels of uranium were collected from the Largo Creek valley west of Quemado, from a small area about 6 km east of Quemado, from a small area surrounding Pie Town, and from scattered locations in the area surrounding Adams Diggings north of Pie Town. Most of the samples containing high uranium concentrations were collected from wells associated with the volcanic sedimentary facies of the Datil formation. This formation is a likely source of mobile uranium that may be precipitating in the underlying Baca formation, a known uranium host unit. Bicarbonate ion concentration, while proportional to uranium concentration in some cases, is not a strong controlling factor in the uranium concentrations in samples from this area.« less
Identification and Quantitative Measurements of Chemical Species by Mass Spectrometry
NASA Technical Reports Server (NTRS)
Zondlo, Mark A.; Bomse, David S.
2005-01-01
The development of a miniature gas chromatograph/mass spectrometer system for the measurement of chemical species of interest to combustion is described. The completed system is a fully-contained, automated instrument consisting of a sampling inlet, a small-scale gas chromatograph, a miniature, quadrupole mass spectrometer, vacuum pumps, and software. A pair of computer-driven valves controls the gas sampling and introduction to the chromatographic column. The column has a stainless steel exterior and a silica interior, and contains an adsorbent of that is used to separate organic species. The detection system is based on a quadrupole mass spectrometer consisting of a micropole array, electrometer, and a computer interface. The vacuum system has two miniature pumps to maintain the low pressure needed for the mass spectrometer. A laptop computer uses custom software to control the entire system and collect the data. In a laboratory demonstration, the system separated calibration mixtures containing 1000 ppm of alkanes and alkenes.
DESIGN OF A SIMPLE SLOW COOLING DEVICE FOR CRYOPRESERVATION OF SMALL BIOLOGICAL SAMPLES.
de Paz, Leonardo Juan; Robert, Maria Celeste; Graf, Daniel Adolfo; Guibert, Edgardo Elvio; Rodriguez, Joaquin Valentin
2015-01-01
Slow cooling is a cryopreservation methodology where samples are cooled to its storage temperature at controlled cooling rates. Design, construction and evaluation of a simple and low cost device for slow cooling of small biological samples. The device was constructed based on Pye's freezer idea. A Dewar flask filled with liquid nitrogen was used as heat sink and a methanol bath containing the sample was cooled at constant rates using copper bars as heat conductor. Sample temperature may be lowered at controlled cooling rate (ranging from 0.4°C/min to 6.0°C/min) down to ~-60°C, where it could be conserved at lower temperatures. An example involving the cryopreservation of Neuro-2A cell line showed a marked influence of cooling rate over post preservation cell viability with optimal values between 2.6 and 4.6°C/min. The cooling device proved to be a valuable alternative to more expensive systems allowing the assessment of different cooling rates to evaluate the optimal condition for cryopreservation of such samples.
A magnetic bead-based method for concentrating DNA from human urine for downstream detection.
Bordelon, Hali; Russ, Patricia K; Wright, David W; Haselton, Frederick R
2013-01-01
Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×10(3) to 5×10(8) copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×10(6), 14×10(6), and 8×10(6) copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR.
A Magnetic Bead-Based Method for Concentrating DNA from Human Urine for Downstream Detection
Bordelon, Hali; Russ, Patricia K.; Wright, David W.; Haselton, Frederick R.
2013-01-01
Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×103 to 5×108 copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×106, 14×106, and 8×106 copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR. PMID:23861895
Cai, Wenjia; Ye, Lin; Zhang, Li; Ren, Yuanhang; Yue, Bin; Chen, Xueying; He, Heyong
2014-01-01
A series of nickel-containing mesoporous silica samples (Ni-SiO2) with different nickel content (3.1%–13.2%) were synthesized by the evaporation-induced self-assembly method. Their catalytic activity was tested in carbon dioxide reforming of methane. The characterization results revealed that the catalysts, e.g., 6.7%Ni-SiO2, with highly dispersed small nickel particles, exhibited excellent catalytic activity and long-term stability. The metallic nickel particle size was significantly affected by the metal anchoring effect between metallic nickel particles and unreduced nickel ions in the silica matrix. A strong anchoring effect was suggested to account for the remaining of small Ni particle size and the improved catalytic performance. PMID:28788570
Mucosal flora of the small intestine and the effect of preoperative antibiotics.
Elmes, M E; Howells, C H; Lowe, G H
1984-01-01
Samples of mucosa from the small intestines of 100 patients undergoing intestinal surgery were examined bacteriologically. Sixty four patients had received chemotherapy, 12 for more than 24 h before operation. Most of the jejunal samples were sterile unless there was a carcinoma, previous surgery, or potential intestinal stasis. Ileal mucosa was more likely to contain intestinal organisms. Most of the strains isolated were sensitive in vitro to the antibiotics given in vivo, but short term treatment may not have allowed sufficient time for the treatment to have become effective. The findings suggest that antibiotics are not needed for most operations on the duodenum or jejunum but may be required for operations on the ileum. PMID:6501588
NASA Technical Reports Server (NTRS)
Johnson, J. R. (Principal Investigator)
1974-01-01
The author has identified the following significant results. The broad scale vegetation classification was developed for a 3,200 sq mile area in southeastern Arizona. The 31 vegetation types were derived from association tables which contained information taken at about 500 ground sites. The classification provided an information base that was suitable for use with small scale photography. A procedure was developed and tested for objectively comparing photo images. The procedure consisted of two parts, image groupability testing and image complexity testing. The Apollo and ERTS photos were compared for relative suitability as first stage stratification bases in two stage proportional probability sampling. High altitude photography was used in common at the second stage.
Dysgenic Fertility, Intelligence and Family Size in Libya
ERIC Educational Resources Information Center
Al-Shahomee, Alsedig Abdalgadr; Lynn, Richard; Abdalla, Saleh El-ghmary
2013-01-01
The Standard Progressive Matrices (SPM) was administered to a sample of 592 16 year old school students in Libya. There was a small negative correlation of -0.14 between SPM scores and the number of siblings, indicating only marginal dysgenic fertility. Supplementary material giving the data is given online. (Contains 1 table.)
Approaches To Teaching Science in the Jordanian Primary School.
ERIC Educational Resources Information Center
Qualter, Anne; Abu-Hola, I. R. A.
2000-01-01
Reports on a study of the influence of different approaches to teaching units from the Jordanian science curriculum on over 600 students from grades 6, 9, and 10. Trains a small sample of male and female teachers in the use of cooperative learning and lecture-demonstration approaches to teaching. (Contains 17 references.) (Author/YDS)
Mossbauer analysis of Luna 16 lunar surface material
NASA Technical Reports Server (NTRS)
Nady, D. L.; Cher, L.; Kulcsar, K.
1974-01-01
Samples of Apollo 11 lunar surface material were studied by the Mossbauer effect. Owing to the small number of other resonant isotopes, all measurements were made with Fe-57 nuclei. The principal constituents of the material were as follows: Iron containing silicates (olivine, pyroxene, and so on), ilmenite (FeTiO3), and metallic iron.
Stuttering Frequency in Relation to Lexical Diversity, Syntactic Complexity, and Utterance Length
ERIC Educational Resources Information Center
Wagovich, Stacy A.; Hall, Nancy E.
2018-01-01
Children's frequency of stuttering can be affected by utterance length, syntactic complexity, and lexical content of language. Using a unique small-scale within-subjects design, this study explored whether language samples that contain more stuttering have (a) longer, (b) syntactically more complex, and (c) lexically more diverse utterances than…
What to Do about Zero Frequency Cells when Estimating Polychoric Correlations
ERIC Educational Resources Information Center
Savalei, Victoria
2011-01-01
Categorical structural equation modeling (SEM) methods that fit the model to estimated polychoric correlations have become popular in the social sciences. When population thresholds are high in absolute value, contingency tables in small samples are likely to contain zero frequency cells. Such cells make the estimation of the polychoric…
Evaluation of asbestos-containing products and released fibers in home appliances.
Hwang, Sung Ho; Park, Wha Me
2016-09-01
The purpose of this study was to detect asbestos-containing products and released asbestos fibers from home appliances. The authors investigated a total of 414 appliances manufactured between 1986 and 2007. Appliances were divided into three categories: large-sized electric appliances, small-sized electric appliances, and household items. Analysis for asbestos-containing material (ACM) was performed using polarized light microscopy (PLM) and stereoscopic microscopy. Air sampling was performed to measure airborne concentration of asbestos using a phase-contrast microscope (PCM). The results of the analysis for ACM in appliances show that large-sized electric appliances (refrigerators, washing machines, kimchi-refrigerators) and household items (bicycles, motorcycles, gas boilers) contain asbestos material and small-sized electric appliances do not contain asbestos material. All appliances with detected asbestos material showed typical characteristics of chrysotile (7-50%) and tremolite (7-10%). No released fibers of ACM were detected from the tested appliances when the appliances were operating. This study gives the basic information on asbestos risk to people who use home appliances. All appliances with detected asbestos material showed typical characteristics of chrysotile (7-50%) and tremolite (7-10%). No released fibers of ACM were detected from the tested appliances when the appliances were operating.
Lorenz, J.J.; McIvor, C.C.; Powell, G.V.N.; Frederick, P.C.
1997-01-01
We describe a 9 m2 drop net and removable walkways designed to quantify densities of small fishes in wetland habitats with low to moderate vegetation density. The method permits the collection of small, quantitative, discrete samples in ecologically sensitive areas by combining rapid net deployment from fixed sites with the carefully contained use of the fish toxicant rotenone. This method requires very little contact with the substrate, causes minimal alteration to the habitat being sampled, samples small fishes in an unbiased manner, and allows for differential sampling of microhabitats within a wetland. When used in dwarf red mangrove (Rhizophora mangle) habitat in southern Everglades National Park and adjacent areas (September 1990 to March 1993), we achieved high recovery efficiencies (78–90%) for five common species <110 mm in length. We captured 20,193 individuals of 26 species. The most abundant fishes were sheepshead minnowCyprinodon variegatus, goldspotted killifishFloridichthys carpio, rainwater killifishLucania parva, sailfin mollyPoecilia latipinna, and the exotic Mayan cichlidCichlasoma urophthalmus. The 9 m2 drop net and associated removable walkways are versatile and can be used in a variety of wetland types, including both interior and coastal wetlands with either herbaceous or woody vegetation.
Stewart, Samantha P; Bell, Steven E J; Fletcher, Nicholas C; Bouazzaoui, Samira; Ho, Yen Cheng; Speers, S James; Peters, K Laota
2012-01-20
Raman spectra of a representative range of β-ketophenethylamine (β-KP), the rapidly growing family of cathinone-related "legal high" recreational drugs, have been recorded. These spectra showed characteristic changes that were associated with the pattern of substitution on the aromatic rings, for example, the compounds carrying substituents at the 4- position could be distinguished from 3,4-methylenedioxy "ecstasy" derivatives. They also showed small but detectable changes with differences in substitution on the ethylamine substituent. These features allowed the β-KPs present in seized casework samples to be identified. The seized samples typically contained only small amounts of bulking agents, which meant that the band intensities of these components within averaged data were very small. In contrast, grid sampling normally gave at least some spectra which had a higher than average proportion of the bulking agent(s), which allowed them to also be identified. This study therefore demonstrates that Raman spectroscopy can be used both to provide a rapid, non-destructive technique for identification of this class of drugs in seized samples and to detect minor constituents, giving a composition profile which can be used for drugs intelligence work. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.
Neutron Polarization Analysis for Biphasic Solvent Extraction Systems
Motokawa, Ryuhei; Endo, Hitoshi; Nagao, Michihiro; ...
2016-06-16
Here we performed neutron polarization analysis (NPA) of extracted organic phases containing complexes, comprised of Zr(NO 3) 4 and tri-n-butyl phosphate, which enabled decomposition of the intensity distribution of small-angle neutron scattering (SANS) into the coherent and incoherent scattering components. The coherent scattering intensity, containing structural information, and the incoherent scattering compete over a wide range of magnitude of scattering vector, q, specifically when q is larger than q* ≈ 1/R g, where R g is the radius of gyration of scatterer. Therefore, it is important to determine the incoherent scattering intensity exactly to perform an accurate structural analysis frommore » SANS data when R g is small, such as the aforementioned extracted coordination species. Although NPA is the best method for evaluating the incoherent scattering component for accurately determining the coherent scattering in SANS, this method is not used frequently in SANS data analysis because it is technically challenging. In this study, we successfully demonstrated that experimental determination of the incoherent scattering using NPA is suitable for sample systems containing a small scatterer with a weak coherent scattering intensity, such as extracted complexes in biphasic solvent extraction systems.« less
Lotspeich, Erica; Kitts, Kelley; Goodpaster, John
2012-07-10
It is a common misconception that the amount of explosive is the chief contributor to the quantity of vapor that is available to trained canines. In fact, this quantity (known as odor availability) depends not only on the amount of explosive material, but also the container volume, explosive vapor pressure and temperature. In order to better understand odor availability, headspace experiments were conducted and the results were compared to theory. The vapor-phase concentrations of three liquid explosives (nitromethane, nitroethane and nitropropane) were predicted using the Ideal Gas Law for containers of various volumes that are in use for canine testing. These predictions were verified through experiments that varied the amount of sample, the container size, and the temperature. These results demonstrated that the amount of sample that is needed to saturate different sized containers is small, predictable and agrees well with theory. In general, and as expected, once the headspace of a container is saturated, any subsequent increase in sample volume will not result in the release of more vapors. The ability of canines to recognize and alert to differing amounts of nitromethane has also been studied. In particular, it was found that the response of trained canines is independent of the amount of nitromethane present, provided it is a sufficient quantity to saturate the container in which it is held. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
The NOSAMS sample preparation laboratory in the next millenium: Progress after the WOCE program
NASA Astrophysics Data System (ADS)
Gagnon, Alan R.; McNichol, Ann P.; Donoghue, Joanne C.; Stuart, Dana R.; von Reden, Karl; Nosams
2000-10-01
Since 1991, the primary charge of the National Ocean Sciences AMS (NOSAMS) facility at the Woods Hole Oceanographic Institution has been to supply high throughput, high precision AMS 14C analyses for seawater samples collected as part of the World Ocean Circulation Experiment (WOCE). Approximately 13,000 samples taken as part of WOCE should be fully analyzed by the end of Y2K. Additional sample sources and techniques must be identified and incorporated if NOSAMS is to continue in its present operation mode. A trend in AMS today is the ability to routinely process and analyze radiocarbon samples that contain tiny amounts (<100 μg) of carbon. The capability to mass-produce small samples for 14C analysis has been recognized as a major facility goal. The installation of a new 134-position MC-SNICS ion source, which utilizes a smaller graphite target cartridge than presently used, is one step towards realizing this goal. New preparation systems constructed in the sample preparation laboratory (SPL) include an automated bank of 10 small-volume graphite reactors, an automated system to process organic carbon samples, and a multi-dimensional preparative capillary gas chromatograph (PCGC).
Post-irradiation-examination of irradiated fuel outside the hot cell
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dawn E. Janney; Adam B. Robinson; Thomas P. O'Holleran
Because of their high radioactivity, irradiated fuels are commonly examined in a hot cell. However, the Idaho National Laboratory (INL) has recently investigated irradiated U-Mo-Al metallic fuel from the Reduced Enrichment for Research and Test Reactors (RERTR) project using a conventional unshielded scanning electron microscope outside a hot cell. This examination was possible because of a two-step sample-preparation approach in which a small volume of fuel was isolated in a hot cell and shielding was introduced during later stages of sample preparation. The resulting sample contained numerous sample-preparation artifacts but allowed analysis of microstructures from selected areas.
Seifertová, Marta; Čechová, Eliška; Llansola, Marta; Felipo, Vicente; Vykoukalová, Martina; Kočan, Anton
2017-10-01
We developed a simple analytical method for the simultaneous determination of representatives of various groups of neurotoxic insecticides (carbaryl, chlorpyrifos, cypermethrin, and α-endosulfan and β-endosulfan and their metabolite endosulfan sulfate) in limited amounts of animal tissues containing different amounts of lipids. Selected tissues (rodent fat, liver, and brain) were extracted in a special in-house-designed mini-extractor constructed on the basis of the Soxhlet and Twisselmann extractors. A dried tissue sample placed in a small cartridge was extracted, while the nascent extract was simultaneously filtered through a layer of sodium sulfate. The extraction was followed by combined clean-up, including gel permeation chromatography (in case of high lipid content), ultrasonication, and solid-phase extraction chromatography using C 18 on silica and aluminum oxide. Gas chromatography coupled with high-resolution mass spectrometry was used for analyte separation, detection, and quantification. Average recoveries for individual insecticides ranged from 82 to 111%. Expanded measurement uncertainties were generally lower than 35%. The developed method was successfully applied to rat tissue samples obtained from an animal model dealing with insecticide exposure during brain development. This method may also be applied to the analytical treatment of small amounts of various types of animal and human tissue samples. A significant advantage achieved using this method is high sample throughput due to the simultaneous treatment of many samples. Graphical abstract Optimized workflow for the determination of selected insecticides in small amounts of animal tissue including newly developed mini-extractor.
Polley, Spencer D.; Mori, Yasuyoshi; Watson, Julie; Perkins, Mark D.; González, Iveth J.; Notomi, Tsugunori; Chiodini, Peter L.; Sutherland, Colin J.
2010-01-01
Loop-mediated isothermal amplification (LAMP) of DNA offers the ability to detect very small quantities of pathogen DNA following minimal tissue sample processing and is thus an attractive methodology for point-of-care diagnostics. Previous attempts to diagnose malaria by the use of blood samples and LAMP have targeted the parasite small-subunit rRNA gene, with a resultant sensitivity for Plasmodium falciparum of around 100 parasites per μl. Here we describe the use of mitochondrial targets for LAMP-based detection of any Plasmodium genus parasite and of P. falciparum specifically. These new targets allow routine amplification from samples containing as few as five parasites per μl of blood. Amplification is complete within 30 to 40 min and is assessed by real-time turbidimetry, thereby offering rapid diagnosis with greater sensitivity than is achieved by the most skilled microscopist or antigen detection using lateral flow immunoassays. PMID:20554824
Möller, T E; Nyberg, M
2003-11-01
A basic extraction procedure for analysis of ochratoxin A (OTA) in currants and raisins is described, as well as the occurrence of OTA and a control of heterogeneity of the toxin in samples bought for two small marketing surveys 1999/2000 and 2001/02. Most samples in the surveys were divided into two subsamples that were individually prepared as slurries and analysed separately. The limit of quantification for the method was estimated as 0.1 microg kg(-1) and recoveries of 85, 90 and 115% were achieved in recovery experiments at 10, 5 and 0.1 microg kg(-1), respectively. Of all 118 subsamples analysed in the surveys, 96 (84%) contained ochratoxin A at levels above the quantification level and five samples (4%) contained more than the European Community legislation of 10 microg kg(-1). The OTA concentrations found in the first survey were in the range < 0.1-19.0 microg kg(-1) with a median concentration of 0.9 microg kg(-1). In the 2001/02 study, the range was < 0.1-34.6 microg kg(-1) with a median of 0.2 microg kg(-1). Big differences were often achieved between individual subsamples of the original sample, which indicate a wide heterogeneous distribution of the toxin. Data from the repeatability test as well as recovery experiments from the same slurries showed that preparation of slurries as described here seemed to give a homogeneous and representative sample. The extraction with the basic sodium bicarbonate-methanol mixture used in the surveys gave similar or somewhat higher OTA values on some samples tested in a comparison with a weak phosphoric acid water-methanol extraction mixture.
Investigation of the tone-burst tube for duct lining attenuation measurement
NASA Technical Reports Server (NTRS)
Soffel, A. R.; Morrow, P. F.
1972-01-01
The tone burst technique makes practical the laboratory evaluation of potential inlet and discharge duct treatments. Tone burst apparatus requires only simple machined parts and standard components. Small, simply made, lining samples are quickly and easily installed in the system. Two small electromagnetric loudspeaker drivers produce peak sound pressure level of over 166 db in the 3-square-inch sample duct. Air pump available in most laboratories can produce air flows of over plus and minus Mach 0.3 in the sample duct. The technique uses short shaped pulses of sound propagated down a progressive wave tube containing the sample duct. The peak pressure level output of the treated duct is compared with the peak pressure level output of a substituted reference duct. The difference between the levels is the attenuation or insertion loss of the treated duct. Evaluations of resonant absorber linings by the tone burst technique check attenuation values predicted by empirical formulas based on full scale ducts.
Ten-Doménech, Isabel; Beltrán-Iturat, Eduardo; Herrero-Martínez, José Manuel; Sancho-Llopis, Juan Vicente; Simó-Alfonso, Ernesto Francisco
2015-06-24
In this work, a method for the separation of triacylglycerols (TAGs) present in human milk and from other mammalian species by reversed-phase high-performance liquid chromatography using a core-shell particle packed column with UV and evaporative light-scattering detectors is described. Under optimal conditions, a mobile phase containing acetonitrile/n-pentanol at 10 °C gave an excellent resolution among more than 50 TAG peaks. A small-scale method for fat extraction in these milks (particularly of interest for human milk samples) using minimal amounts of sample and reagents was also developed. The proposed extraction protocol and the traditional method were compared, giving similar results, with respect to the total fat and relative TAG contents. Finally, a statistical study based on linear discriminant analysis on the TAG composition of different types of milks (human, cow, sheep, and goat) was carried out to differentiate the samples according to their mammalian origin.
Small D-type asteroids in the NEO population: new targets for space missions
NASA Astrophysics Data System (ADS)
Barucci, Maria Antonietta; Perna, D.; Popescu, M.; Fornasier, S.; Doressoundiram, A.; Lantz, C.; Merlin, F.; Fulchignoni, M.; Dotto, E.; Kanuchova, S.
2018-06-01
In the framework of the Near Earth Objects (NEOs) observational campaign carried out within the NEOShield-2 project, we identify nine new small D-type asteroids with estimated diameter less than 600 m. The link with meteorites for this class of asteroids is weak and the best fit obtained is with the Tagish Lake meteorite for seven of them. D-type asteroids are believed to contain the most pristine material of the Solar system and could have delivered the pre-biotic material to the Earth. Our results double the known sample of the D-types in the NEO population and triple the candidates of this class for a sample-return mission (at very low ΔV). Our finding increases considerably the number of targets for sample-return mission. A sample-return mission to a D-type asteroid will provide a major progress in understanding the early history of the Solar system and to investigate the origin of life on the Earth.
NASA Astrophysics Data System (ADS)
She, Qi; Chen, Guanrong; Chan, Rosa H. M.
2016-02-01
The amount of publicly accessible experimental data has gradually increased in recent years, which makes it possible to reconsider many longstanding questions in neuroscience. In this paper, an efficient framework is presented for reconstructing functional connectivity using experimental spike-train data. A modified generalized linear model (GLM) with L1-norm penalty was used to investigate 10 datasets. These datasets contain spike-train data collected from the entorhinal-hippocampal region in the brains of rats performing different tasks. The analysis shows that entorhinal-hippocampal network of well-trained rats demonstrated significant small-world features. It is found that the connectivity structure generated by distance-dependent models is responsible for the observed small-world features of the reconstructed networks. The models are utilized to simulate a subset of units recorded from a large biological neural network using multiple electrodes. Two metrics for quantifying the small-world-ness both suggest that the reconstructed network from the sampled nodes estimates a more prominent small-world-ness feature than that of the original unknown network when the number of recorded neurons is small. Finally, this study shows that it is feasible to adjust the estimated small-world-ness results based on the number of neurons recorded to provide a more accurate reference of the network property.
NASA Technical Reports Server (NTRS)
Goreva, Y. S.; Humanyun, M.; Burnett, D. S.; Jurewicz, A. J.; Gonzalez, C. P.
2014-01-01
ToF-SIMS images of Genesis sample surfaces contain an incredible amount of important information, but they also show that the crash-derived surface contamination has many components, presenting a challenge to cleaning. Within the variability, we have shown that there are some samples which appear to be clean to begin with, e.g. 60471, and some are more contaminated. Samples 60493 and 60500 are a part of a focused study of the effectiveness of aqua regia and/or sulfuric acid cleaning of small flight Si implanted with Li-6 using ToF-SIMS.
Touch and Go Surface Sampler (TGSS)
NASA Technical Reports Server (NTRS)
Gorevan, S. P.; Rafeek, S.
2001-01-01
The Touch and Go Surface Sampler (TGSS) is a new class of planetary and small body sample acquisition tool that can be used for the surface exploration of Europa, Titan and comets. TGSS in its basic configuration consists of a high speed sampling head attached to the end of a flexible shaft. The sampling head consists of counter rotating cutters that rotates at speeds of 3000 to 15000 RPM. The attractive feature of this if touch and go type sampler is that there are no requirements for a lander type spacecraft. Additional information is contained in the original extended abstract.
The photochemistry of pyrimidine in realistic astrophysical ices and the production of nucleobases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nuevo, Michel; Materese, Christopher K.; Sandford, Scott A., E-mail: michel.nuevo-1@nasa.gov
2014-10-01
Nucleobases, together with deoxyribose/ribose and phosphoric acid, are the building blocks of DNA and RNA for all known life. The presence of nucleobase-like compounds in carbonaceous chondrites delivered to the Earth raises the question of an extraterrestrial origin for the molecules that triggered life on our planet. Whether these molecules are formed in interstellar/protostellar environments, in small parent bodies in the solar system, or both, is currently unclear. Recent experiments show that the UV irradiation of pyrimidine (C{sub 4}H{sub 4}N{sub 2}) in H{sub 2}O-rich ice mixtures that contain NH{sub 3}, CH{sub 3}OH, or CH{sub 4} leads to the formation ofmore » the pyrimidine-based nucleobases uracil, cytosine, and thymine. In this work, we discuss the low-temperature UV irradiation of pyrimidine in realistic astrophysical ice mixtures containing H{sub 2}O, CH{sub 3}OH, and NH{sub 3}, with or without CH{sub 4}, to search for the production of nucleobases and other prebiotic compounds. These experiments show the presence of uracil, urea, glycerol, hexamethylenetetramine, small amino acids, and small carboxylic acids in all samples. Cytosine was only found in one sample produced from ices irradiated with a higher UV dose, while thymine was not found in any sample, even after irradiation with a higher UV dose. Results are discussed to evaluate the role of the photochemistry of pyrimidine in the inventory of organic molecules detected in meteorites and their astrophysical/astrobiological implications.« less
Anomalous small-angle scattering as a way to solve the Babinet principle problem
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boiko, M. E., E-mail: m.e.boiko@mail.ioffe.ru; Sharkov, M. D.; Boiko, A. M.
2013-12-15
X-ray absorption spectra (XAS) have been used to determine the absorption edges of atoms present in a sample under study. A series of small-angle X-ray scattering (SAXS) measurements using different monochromatic X-ray beams at different wavelengths near the absorption edges is performed to solve the Babinet principle problem. The sizes of clusters containing atoms determined by the method of XAS were defined in SAXS experiments. In contrast to differential X-ray porosimetry, anomalous SAXS makes it possible to determine sizes of clusters of different atomic compositions.
Anomalous small-angle scattering as a way to solve the Babinet principle problem
NASA Astrophysics Data System (ADS)
Boiko, M. E.; Sharkov, M. D.; Boiko, A. M.; Bobyl, A. V.
2013-12-01
X-ray absorption spectra (XAS) have been used to determine the absorption edges of atoms present in a sample under study. A series of small-angle X-ray scattering (SAXS) measurements using different monochromatic X-ray beams at different wavelengths near the absorption edges is performed to solve the Babinet principle problem. The sizes of clusters containing atoms determined by the method of XAS were defined in SAXS experiments. In contrast to differential X-ray porosimetry, anomalous SAXS makes it possible to determine sizes of clusters of different atomic compositions.
Organic Sulfur Associated with Aquatic Humic Substances
NASA Astrophysics Data System (ADS)
Aiken, G.; Vairavamurthy, M. A.; Ravichandran, M.
2003-12-01
This study examines the speciation and reactivity of organic sulfur associated with dissolved organic matter isolated from a variety of freshwater environments and the Pacific Ocean. The isolates, which included aquatic humic substances, were obtained using XAD resins and exhibited a wide range of elemental compositions, aromatic carbon contents, and molecular weights. Organic sulfur contents for the samples ranged from 0.4% to 1.9% of the atomic composition and were strongly dependent on the redox chemistry of the environments whence the samples originated, especially with regard to potential interactions with sulfide in sulfate reducing environments. The speciation of the sulfur associated with these samples was investigated using X-ray adsorption near edge spectroscopy (XANES). The samples, all obtained from oxic environments, contained reduced sulfur moieties. Reduced sulfur content (thiophene, organic sulfides and thiols) ranged from 22-70%. In general, humic acid fractions were found to have the largest percentage of reduced sulfur, followed by the fulvic acid and hydrophobic acid fractions. Hydrophilic fractions of the DOC contained a large percentage of oxidized organic sulfur (sulfonate and sulfate moieties). To assess the significance of reduced S content on interactions with soft metals, an environmentally significant process, the binding strength and binding capacity of Hg with organic matter isolated from the Florida Everglades were determined using equilibrium dialysis ligand exchange. Based on elemental analyses and XANES, the DOM sample from the Everglades used in our binding experiments had a reduced-S content of approximately 1.0%. Very strong interactions (KDOM' = 1023.2+/-0.5 L kg-1) were observed at Hg/DOM ratios below approximately 1 μ g Hg per mg DOM. Only a small fraction (approximately 2%) of the reduced-S groups were involved with the strongest interactions between Hg and DOM, suggesting that the binding of Hg to DOM under natural conditions (very low Hg/DOM ratios ranging from 0.01 to 10 ng of Hg/mg of DOM) is controlled by a small fraction of DOM molecules containing reactive sulfur functional groups.
Parrish, Randall R; Thirlwall, Matthew F; Pickford, Chris; Horstwood, Matthew; Gerdes, Axel; Anderson, James; Coggon, David
2006-02-01
Accidental exposure to depleted or enriched uranium may occur in a variety of circumstances. There is a need to quantify such exposure, with the possibility that the testing may post-date exposure by months or years. Therefore, it is important to develop a very sensitive test to measure precisely the isotopic composition of uranium in urine at low levels of concentration. The results of an interlaboratory comparison using sector field (SF)-inductively coupled plasma-mass spectrometry (ICP-MS) and multiple collector (MC)-ICP-MS for the measurement of uranium concentration and U/U and U/U isotopic ratios of human urine samples are presented. Three urine samples were verified to contain uranium at 1-5 ng L and shown to have natural uranium isotopic composition. Portions of these urine batches were doped with depleted uranium (DU) containing small quantities of U, and the solutions were split into 100 mL and 400 mL aliquots that were subsequently measured blind by three laboratories. All methods investigated were able to measure accurately U/U with precisions of approximately 0.5% to approximately 4%, but only selected MC-ICP-MS methods were capable of consistently analyzing U/U to reasonable precision at the approximately 20 fg L level of U abundance. Isotope dilution using a U tracer demonstrates the ability to measure concentrations to better than +/-4% with the MC-ICP-MS method, though sample heterogeneity in urine samples was shown to be problematic in some cases. MC-ICP-MS outperformed SF-ICP-MS methods, as was expected. The MC-ICP-MS methodology described is capable of measuring to approximately 1% precision the U/U of any sample of human urine over the entire range of uranium abundance down to <1 ng L, and detecting very small amounts of DU contained therein.
PRESENCE OF CITRININ IN GRAINS AND ITS POSSIBLE HEALTH EFFECTS.
Čulig, Borna; Bevardi, Martina; Bošnir, Jasna; Serdar, Sonja; Lasić, Dario; Racz, Aleksandar; Galić, Antonija; Kuharić, Željka
2017-01-01
Citrinin is a mycotoxin produced by several species of the genera Aspergillus , Penicillium and Monascus and it occurs mainly in stored grain. Citrinin is generally formed after harvest and occurs mainly in stored grains, it also occurs in other plant products. Often, the co-occurrence with other mycotoxins is observed, especially ochratoxin A, which is usually associated with endemic nephropathy. At the European Union level, systematic monitoring of Citrinin in grains began with the aim of determining its highest permissible amount in food. Thus, far the systematic monitoring of the above mentioned mycotoxin in Croatia is yet to begin. The main goal of this study was to determine the presence of Citrinin in grains sampled in the area of Međimurje, Osijek-Baranja, Vukovar-Srijem and Brod-Posavina County. For the purpose of identification and quantification of citrinin, high performance liquid chromatograph (HPLC) with fluorescence was used (Calibration curve k > 0.999; Intra assay CV = 2.1%; Inter assay CV = 4.3%; LOQ < 1 μg/kg). From the area of Međimurje County, 10 samples of corn and 10 samples of wheat were analyzed. None of the samples contained Citrinin (<1 μg/kg). From the area of Osijek-Baranja and Vukovar-Srijem County, 15 samples from each County were analyzed. The mean value for the samples of Osijek-Baranja County was 19.63 μg/kg (median=15.8 μg/kg), while for Vukovar-Srijem County the mean value of citrinin was 14,6 μg/kg (median=1.23 μg/kg). From 5 analyzed samples from Brod-Posavina County, one of the samples contained citrinin in the amount of 23.8 μg/kg, while the registered amounts in the other samples were <1 μg/kg. The results show that grains from several Counties contain certain amounts of Citrinin possibly indicating a significant intake of citrinin in humans. It must be stated that grains and grain-based products are the basis of everyday diet of all age groups, especially small children, where higher intake of citrinin can occur. Consequently, we emphasize the need for systematic analysis of larger amount of samples, from both large grains and small grains, especially in the area of Brod-Posavina County, in order to obtain more realistic notion of citrinin contamination of grains and to asses the health risk in humans.
ERIC Educational Resources Information Center
Cantrill, Christina, Comp.; Glass, Don, Comp.; Sparks, Andrew, Comp.
This document is a tool to help teachers look at student work as a means to assess individual student progress. It contains work samples, accompanying commentaries, and assessment tools which originate from students and teachers in Philadelphia public schools who participated in the Philadelphia Education Fund's Small Learning Community…
Clausen, J L; Georgian, T; Gardner, K H; Douglas, T A
2018-01-01
This study compares conventional grab sampling to incremental sampling methodology (ISM) to characterize metal contamination at a military small-arms-range. Grab sample results had large variances, positively skewed non-normal distributions, extreme outliers, and poor agreement between duplicate samples even when samples were co-located within tens of centimeters of each other. The extreme outliers strongly influenced the grab sample means for the primary contaminants lead (Pb) and antinomy (Sb). In contrast, median and mean metal concentrations were similar for the ISM samples. ISM significantly reduced measurement uncertainty of estimates of the mean, increasing data quality (e.g., for environmental risk assessments) with fewer samples (e.g., decreasing total project costs). Based on Monte Carlo resampling simulations, grab sampling resulted in highly variable means and upper confidence limits of the mean relative to ISM.
Sorption Isotherm of Southern Yellow Pine-High Density Polyethylene Composites.
Liu, Feihong; Han, Guangping; Cheng, Wanli; Wu, Qinglin
2015-01-20
Temperature and relative humidity (RH) are two major external factors, which affect equilibrium moisture content (EMC) of wood-plastic composites (WPCs). In this study, the effect of different durability treatments on sorption and desorption isotherms of southern yellow pine (SYP)-high density polyethylene (HDPE) composites was investigated. All samples were equilibriumed at 20 °C and various RHs including 16%, 33%, 45%, 66%, 75%, 85%, 93%, and100%. EMCs obtained from desorption and absorption for different WPC samples were compared with Nelson's sorption isotherm model predictions using the same temperature and humidity conditions. The results indicated that the amount of moisture absorbed increased with the increases in RH at 20 °C. All samples showed sorption hysteresis at a fixed RH. Small difference between EMC data of WPC samples containing different amount of ultraviolet (UV) stabilizers were observed. Similar results were observed among the samples containing different amount of zinc borate (ZB). The experimental data of EMCs at various RHs fit to the Nelson's sorption isotherm model well. The Nelson's model can be used to predicate EMCs of WPCs under different RH environmental conditions.
Sorption Isotherm of Southern Yellow Pine—High Density Polyethylene Composites
Liu, Feihong; Han, Guangping; Cheng, Wanli; Wu, Qinglin
2015-01-01
Temperature and relative humidity (RH) are two major external factors, which affect equilibrium moisture content (EMC) of wood-plastic composites (WPCs). In this study, the effect of different durability treatments on sorption and desorption isotherms of southern yellow pine (SYP)-high density polyethylene (HDPE) composites was investigated. All samples were equilibriumed at 20 °C and various RHs including 16%, 33%, 45%, 66%, 75%, 85%, 93%, and100%. EMCs obtained from desorption and absorption for different WPC samples were compared with Nelson’s sorption isotherm model predictions using the same temperature and humidity conditions. The results indicated that the amount of moisture absorbed increased with the increases in RH at 20 °C. All samples showed sorption hysteresis at a fixed RH. Small difference between EMC data of WPC samples containing different amount of ultraviolet (UV) stabilizers were observed. Similar results were observed among the samples containing different amount of zinc borate (ZB). The experimental data of EMCs at various RHs fit to the Nelson’s sorption isotherm model well. The Nelson’s model can be used to predicate EMCs of WPCs under different RH environmental conditions. PMID:28787943
Airborne asbestos exposures associated with work on asbestos fire sleeve materials.
Blake, Charles L; Harbison, Stephen C; Johnson, Giffe T; Harbison, Raymond D
2011-11-01
Asbestos-containing fire sleeves have been used as a fire protection measure for aircraft fluid hoses. This investigation was conducted to determine the level of airborne asbestos fiber exposure experienced by mechanics who work with fire sleeve protected hoses. Duplicate testing was performed inside a small, enclosed workroom during the fabrication of hose assemblies. Personal air samples taken during this work showed detectable, but low airborne asbestos fiber exposures. Analysis of personal samples (n=9) using phrase contract microscopy (PCM) indicated task duration airborne fiber concentrations ranging from 0.017 to 0.063 fibers per milliliter (f/ml) for sampling durations of 167-198 min, and 0.022-0.14 f/ml for 30 min samples. Airborne chrysotile fibers were detected for four of these nine personal samples, and the resulting asbestos adjusted airborne fiber concentrations ranged from 0.014 to 0.025 f/ml. These results indicate that work with asbestos fire sleeve and fire sleeve protected hose assemblies, does not produce regulatory noncompliant levels of asbestos exposure for persons who handle, cut and fit these asbestos-containing materials. Copyright © 2011 Elsevier Inc. All rights reserved.
Small system for tritium accelerator mass spectrometry
Roberts, M.L.; Davis, J.C.
1993-02-23
Apparatus for ionizing and accelerating a sample containing isotopes of hydrogen and detecting the ratios of hydrogen isotopes contained in the sample is disclosed. An ion source generates a substantially linear ion beam including ions of tritium from the sample. A radio-frequency quadrupole accelerator is directly coupled to and axially aligned with the source at an angle of substantially zero degrees. The accelerator accelerates species of the sample having different mass to different energy levels along the same axis as the ion beam. A spectrometer is used to detect the concentration of tritium ions in the sample. In one form of the invention, an energy loss spectrometer is used which includes a foil to block the passage of hydrogen, deuterium and [sup 3]He ions, and a surface barrier or scintillation detector to detect the concentration of tritium ions. In another form of the invention, a combined momentum/energy loss spectrometer is used which includes a magnet to separate the ion beams, with Faraday cups to measure the hydrogen and deuterium and a surface barrier or scintillation detector for the tritium ions.
Small system for tritium accelerator mass spectrometry
Roberts, Mark L.; Davis, Jay C.
1993-01-01
Apparatus for ionizing and accelerating a sample containing isotopes of hydrogen and detecting the ratios of hydrogen isotopes contained in the sample is disclosed. An ion source generates a substantially linear ion beam including ions of tritium from the sample. A radio-frequency quadrupole accelerator is directly coupled to and axially aligned with the source at an angle of substantially zero degrees. The accelerator accelerates species of the sample having different mass to different energy levels along the same axis as the ion beam. A spectrometer is used to detect the concentration of tritium ions in the sample. In one form of the invention, an energy loss spectrometer is used which includes a foil to block the passage of hydrogen, deuterium and .sup.3 He ions, and a surface barrier or scintillation detector to detect the concentration of tritium ions. In another form of the invention, a combined momentum/energy loss spectrometer is used which includes a magnet to separate the ion beams, with Faraday cups to measure the hydrogen and deuterium and a surface barrier or scintillation detector for the tritium ions.
Verspoor, E; Knox, D; Marshall, S
2016-12-01
An eclectic set of tissues and existing data, including purposely collected samples, spanning 1997-2006, was used in an ad hoc assessment of hybridization and introgression of farmed wild Atlantic salmon Salmo salar in the small Loch na Thull (LnT) catchment in north-west Scotland. The catchment is in an area of marine farm production and contains freshwater smolt rearing cages. The LnT S. salar stock was found to be genetically distinctive from stocks in neighbouring rivers and, despite regular reports of feral farm S. salar, there was no evidence of physical or genetic mixing. This cannot be completely ruled out, however, and low level mixing with other local wild stocks has been suggested. The LnT population appeared underpinned by relatively smaller effective number of breeders (N eb ) and showed relatively low levels of genetic diversity, consistent with a small effective population size. Small sample sizes, an incomplete farm baseline and the use of non-diagnostic molecular markers, constrain the power of the analysis but the findings strongly support the LnT catchment having a genetically distinct wild S. salar population little affected by interbreeding with feral farm escapes. © 2016 The Fisheries Society of the British Isles.
Krivosheeva, Olga; Dedinaite, Andra; Claesson, Per M
2013-10-15
Mussel adhesive proteins are of great interest in many applications due to their ability to bind strongly to many types of surfaces under water. Effective use such proteins, for instance the Mytilus edulis foot protein - Mefp-1, for surface modification requires achievement of a large adsorbed amount and formation of a layer that is resistant towards desorption under changing conditions. In this work we compare the adsorbed amount and layer properties obtained by using a sample containing small Mefp-1 aggregates with that obtained by using a non-aggregated sample. We find that the use of the sample containing small aggregates leads to higher adsorbed amount, larger layer thickness and similar water content compared to what can be achieved with a non-aggregated sample. The layer formed by the aggregated Mefp-1 was, after removal of the protein from bulk solution, exposed to aqueous solutions with high ionic strength (up to 1M NaCl) and to solutions with low pH in order to reduce the electrostatic surface affinity. It was found that the preadsorbed Mefp-1 layer under all conditions explored was significantly more resistant towards desorption than a layer built by a synthetic cationic polyelectrolyte with similar charge density. These results suggest that the non-electrostatic surface affinity for Mefp-1 is larger than for the cationic polyelectrolyte. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.
Small-scale thermal studies of volatile homemade explosives
Sandstrom, Mary M.; Brown, Geoffrey W.; Warner, Kirsten F.; ...
2016-01-26
Several homemade or improvised explosive mixtures that either contained volatile components or produced volatile products were examined using standard small-scale safety and thermal (SSST) testing that employed differential scanning calorimetry (DSC) techniques (constant heating rate and standard sample holders). KClO 3 and KClO 4 mixtures with dodecane exhibited different enthalpy behavior when using a vented sample holder in contrast to a sealed sample holder. The standard configuration produced profiles that exhibited only endothermic transitions. The sealed system produced profiles that exhibited additional exothermic transitions absent in the standard configuration produced profiles. When H 2O 2/fuel mixtures were examined, the volatilizationmore » of the peroxide (endothermic) dominated the profiles. When a sealed sample holder was used, the energetic releases of the mixture could be clearly observed. For AN and AN mixtures, the high temperature decomposition appears as an intense endothermic event. Using a nominally sealed sample holder also did not adequately contain the system. Only when a high-pressure rated sample holder was used the high temperature decomposition of the AN could be detected as an exothermic release. The testing was conducted during a proficiency (or round-robin type) test that included three U.S. Department of Energy and two U.S. Department of Defense laboratories. In the course of this proficiency test, certain HMEs exhibited thermal behavior that was not adequately accounted for by standard techniques. Further examination of this atypical behavior highlighted issues that may have not been recognized previously because some of these materials are not routinely tested. More importantly, if not recognized, the SSST testing results could lead to inaccurate safety assessments. Furthermore, this study provides examples, where standard techniques can be applied, and results can be obtained, but these results may be misleading in establishing thermal properties.« less
The Pharmacological Activity of Extracts of Cotton Dust
Davenport, Anne; Paton, W. D. M.
1962-01-01
Aqueous extracts prepared from dust collected in the card-rooms of several cotton mills have been prepared and found to contain activity which contracts the smooth muscle of guinea-pig ileum, guinea-pig trachea, rat stomach strip, and rat duodenum. The extracts contained an unknown contractor substance which was dialysable, resistant to boiling for one hour, and not destroyed by the action of proteolytic enzymes. They also contained a small amount of 5-hydroxytryptamine. One of the dust samples also contained histamine, but it could not be detected in the other samples, one of which was known to possess bronchoconstrictor properties in man. The particulate material, even after repeated washing, was found to have some stimulant action on guinea-pig ileum. There was no evidence for the release of histamine by the extracts in either cats or guinea-pigs, although a very small amount was released in rats. Jute dust is much less active than cotton dust, and the activity differs qualitatively. Cotton dust extracts were found to have pyrogenic activity but it is unlikely that pyrogens were responsible for the smooth-muscle contractor properties. Experiments with whole animals suggest that although smooth-muscle contracting substances were present in the extracts, it is possible that the symptoms of byssinosis are caused by the release of some other active bronchoconstrictor substance in the tissues. The mechanism of the release is not known; it may be caused by a soluble principle in the extract or due to the presence of particulate matter in the dust. Images PMID:13883719
Khumaeni, Ali; Ramli, Muliadi; Deguchi, Yoji; Lee, Yong Inn; Idris, Nasrullah; Kurniawan, Koo Hendrik; Lie, Tjung Jie; Kagawa, Kiichiro
2008-12-01
Taking advantage of the differences between the interactions of transversely excited atmospheric (TEA) CO(2) lasers with metal and with organic powder, a new technique for the direct analysis of food powder samples has been developed. In this technique, the powder samples were placed into a small hole with a diameter of 2 mm and a depth of 3 mm and covered by a metal mesh. The TEA CO(2) laser (1500 mJ, 200 ns) was focused on the powder sample surfaces, passing through the metal mesh, at atmospheric pressure in nitrogen gas. It is hypothesized that the small hole functions to confine the powder particles and suppresses the blowing-off of sample, while the metal mesh works as the source of electrons to initiate the strong gas breakdown plasma. The confined powder particles are then ablated by laser irradiation and the ablated particles move into the strong gas breakdown plasma region to be atomized and excited; this method cannot be applied for the case of Nd:YAG lasers because in such case the metal mesh itself was ablated by the laser irradiation. A quantitative analysis of a milk powder sample containing different concentrations of Ca was successfully demonstrated, resulting in a good linear calibration curve with high precision.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanulik, J.
1983-09-20
A sample-taking appliance comprises several sensors arranged on a turntable like sensor carrier in such a manner that the application areas of the small sensor sponges decrease stepwise from the first to the last sensor. By simple rotation of the turntable the sensors can be brought successively into a working position. The sensor carrier is preferably accommodated in a housing which is open at the bottom and which is raisable and lowerable in the frame of the appliance by, for example, a threaded spindle. The threaded spindle is driven by an electric motor. For each sampling the sensor carrier ismore » lowered until the cell voltage corresponds to a predetermined desired value. This produces sufficiently precise and reproductible measured values of the electrolytic current for ascertaining the removed layer thickness. The appliance makes it possible to take material samples even from locations of high radiation loading. The material layers removed as samples lie concentrically above each other so that the graduation of the application areas comes into full effect and the material samples taken by the small sponges and the radioactivity contained therein are not falsified.« less
WONG, JACKLYN; ASTETE, HELVIO; MORRISON, AMY C.; SCOTT, THOMAS W.
2011-01-01
When devising methods to sample Aedes aegypti (L.) eggs from naturally-occurring containers to investigate selective oviposition, failure to take into account certain aspects of Ae. aegypti behavior can bias study inferences. In Iquitos, Peru, we tested three assumptions related to designing Ae. aegypti oviposition field studies, as follows: 1) lining containers with paper as an oviposition substrate does not affect oviposition; 2) diurnal egg-laying activity peaks in the late afternoon or early evening, and there is little oviposition during midday; and 3) the gonotrophic cycle length of wild females averages from 3 to 4 d. When wild females were presented with containers lined and unlined with paper toweling, the presence of paper increased oviposition in plastic and metal containers, but had no effect in cement containers. Recording the number of eggs laid by Ae. aegypti every 2 h throughout the day delineated a bimodal diurnal oviposition pattern, with a small morning peak, decreased activity during midday, and a predominant peak in the late afternoon and evening from 16:00 to 20:00 h. Daily monitoring of captive individual F0 females revealed that the gonotrophic cycle length was typically 3– 4 d for the Iquitos population. These findings will be used to adjust field study design to 1) account for sampling eggs using paper toweling, and 2) determine the time of day and number of days over which to sample Ae. aegypti eggs. We explored how failure to consider these behaviors could potentially bias field assessments of oviposition preferences. PMID:21337947
Ren, Xinxin; Liu, Jia; Zhang, Chengsen; Luo, Hai
2013-03-15
With the rapid development of ambient mass spectrometry, the hybrid laser-based ambient ionization methods which can generate multiply charged ions of large biomolecules and also characterize small molecules with good signal-to-noise in both positive and negative ion modes are of particular interest. An ambient ionization method termed high-voltage-assisted laser desorption ionization (HALDI) is developed, in which a 1064 nm laser is used to desorb various liquid samples from the sample target biased at a high potential without the need for an organic matrix. The pre-charged liquid samples are desorbed by the laser to form small charged droplets which may undergo an electrospray-like ionization process to produce multiply charged ions of large biomolecules. Various samples including proteins, oligonucleotides (ODNs), drugs, whole milk and chicken eggs have been analyzed by HALDI-MS in both positive and negative ion mode with little or no sample preparation. In addition, HALDI can generate intense signals with better signal-to-noise in negative ion mode than laser desorption spay post-ionization (LDSPI) from the same samples, such as ODNs and some carboxylic-group-containing small drug molecules. HALDI-MS can directly analyze a variety of liquid samples including proteins, ODNs, pharmaceuticals and biological fluids in both positive and negative ion mode without the use of an organic matrix. This technique may be further developed into a useful tool for rapid analysis in many different fields such as pharmaceutical, food, and biological sciences. Copyright © 2013 John Wiley & Sons, Ltd.
Green, Michael V; Seidel, Jurgen; Choyke, Peter L; Jagoda, Elaine M
2017-10-01
We describe a simple fixture that can be added to the imaging bed of a small-animal PET scanner that allows for automated counting of multiple organ or tissue samples from mouse-sized animals and counting of injection syringes prior to administration of the radiotracer. The combination of imaging and counting capabilities in the same machine offers advantages in certain experimental settings. A polyethylene block of plastic, sculpted to mate with the animal imaging bed of a small-animal PET scanner, is machined to receive twelve 5-ml containers, each capable of holding an entire organ from a mouse-sized animal. In addition, a triangular cross-section slot is machined down the centerline of the block to secure injection syringes from 1-ml to 3-ml in size. The sample holder is scanned in PET whole-body mode to image all samples or in one bed position to image a filled injection syringe. Total radioactivity in each sample or syringe is determined from the reconstructed images of these objects using volume re-projection of the coronal images and a single region-of-interest for each. We tested the accuracy of this method by comparing PET estimates of sample and syringe activity with well counter and dose calibrator estimates of these same activities. PET and well counting of the same samples gave near identical results (in MBq, R 2 =0.99, slope=0.99, intercept=0.00-MBq). PET syringe and dose calibrator measurements of syringe activity in MBq were also similar (R 2 =0.99, slope=0.99, intercept=- 0.22-MBq). A small-animal PET scanner can be easily converted into a multi-sample and syringe counting device by the addition of a sample block constructed for that purpose. This capability, combined with live animal imaging, can improve efficiency and flexibility in certain experimental settings. Copyright © 2017 Elsevier Inc. All rights reserved.
Whole Grains Contribute Only a Small Proportion of Dietary Fiber to the U.S. Diet.
Kranz, Sibylle; Dodd, Kevin W; Juan, Wen Yen; Johnson, LuAnn K; Jahns, Lisa
2017-02-17
Dietary fiber (DF), found in whole fruits, vegetables, and whole grains (WG), is considered a nutrient of concern in the US diet and increased consumption is recommended. The present study was designed to highlight this critical importance of the difference between WG, high-fiber WG, and sources of fiber that are not from WG. The study is based on the two-day diets reported consumed by the nationally representative sample of Americans participating in What We Eat In America, the dietary component of the National Health and Nutrition Examination Survey from 2003-2010. Foods consumed were classified into tertiles of DF and WG and the contribution of fiber by differing levels of WG content were examined. Foods containing high amounts of WG and DF only contributed about 7% of total fiber intake. Overall, grain-based foods contributed 54.5% of all DF consumed. Approximately 39% of DF came from grain foods that contained no WG, rather these foods contained refined grains, which contain only small amounts of DF but are consumed in large quantities. All WG-containing foods combined contributed a total of 15.3% of DF in the American diet. Thus, public health messaging needs to be changed to specifically encourage consumption of WG foods with high levels of DF to address both recommendations.
Duncan, Charles P.
1983-01-01
An improved collecting apparatus for small aquatic or airborne organisms such as plankton, larval fish, insects, etc. The improvement constitutes an apertured removal container within which is retained a collecting bag, and which is secured at the apex of a conical collecting net. Such collectors are towed behind a vessel or vehicle with the open end of the conical net facing forward for trapping the aquatic or airborne organisms within the collecting bag, while allowing the water or air to pass through the apertures in the container. The container is readily removable from the collecting net whereby the collecting bag can be quickly removed and replaced for further sample collection. The collecting bag is provided with means for preventing the bag from being pulled into the container by the water or air flowing therethrough.
Cryptosporidium parvum Infection Involving Novel Genotypes in Wildlife from Lower New York State
Perz, Joseph F.; Le Blancq, Sylvie M.
2001-01-01
Cryptosporidium, an enteric parasite of humans and a wide range of other mammals, presents numerous challenges to the supply of safe drinking water. We performed a wildlife survey, focusing on white-tailed deer and small mammals, to assess whether they may serve as environmental sources of Cryptosporidium. A PCR-based approach that permitted genetic characterization via sequence analysis was applied to wildlife fecal samples (n = 111) collected from September 1996 to July 1998 from three areas in lower New York State. Southern analysis revealed 22 fecal samples containing Cryptosporidium small-subunit (SSU) ribosomal DNA; these included 10 of 91 white-tailed deer (Odocoileus virginianus) samples, 3 of 5 chipmunk (Tamias striatus) samples, 1 of 2 white-footed mouse (Peromyscus leucopus) samples, 1 of 2 striped skunk (Mephitis mephitis) samples, 1 of 5 racoon (Procyon lotor) samples, and 6 of 6 muskrat (Ondatra zibethicus) samples. All of the 15 SSU PCR products sequenced were characterized as Cryptosporidium parvum; two were identical to genotype 2 (bovine), whereas the remainder belonged to two novel SSU sequence groups, designated genotypes 3 and 4. Genotype 3 comprised four deer-derived sequences, whereas genotype 4 included nine sequences from deer, mouse, chipmunk, and muskrat samples. PCR analysis was performed on the SSU-positive fecal samples for three other Cryptosporidium loci (dihydrofolate reductase, polythreonine-rich protein, and beta-tubulin), and 8 of 10 cloned PCR products were consistent with C. parvum genotype 2. These data provide evidence that there is sylvatic transmission of C. parvum involving deer and other small mammals. This study affirmed the importance of wildlife as potential sources of Cryptosporidium in the catchments of public water supplies. PMID:11229905
Cryptosporidium parvum infection involving novel genotypes in wildlife from lower New York State.
Perz, J F; Le Blancq, S M
2001-03-01
Cryptosporidium, an enteric parasite of humans and a wide range of other mammals, presents numerous challenges to the supply of safe drinking water. We performed a wildlife survey, focusing on white-tailed deer and small mammals, to assess whether they may serve as environmental sources of Cryptosporidium. A PCR-based approach that permitted genetic characterization via sequence analysis was applied to wildlife fecal samples (n = 111) collected from September 1996 to July 1998 from three areas in lower New York State. Southern analysis revealed 22 fecal samples containing Cryptosporidium small-subunit (SSU) ribosomal DNA; these included 10 of 91 white-tailed deer (Odocoileus virginianus) samples, 3 of 5 chipmunk (Tamias striatus) samples, 1 of 2 white-footed mouse (Peromyscus leucopus) samples, 1 of 2 striped skunk (Mephitis mephitis) samples, 1 of 5 racoon (Procyon lotor) samples, and 6 of 6 muskrat (Ondatra zibethicus) samples. All of the 15 SSU PCR products sequenced were characterized as Cryptosporidium parvum; two were identical to genotype 2 (bovine), whereas the remainder belonged to two novel SSU sequence groups, designated genotypes 3 and 4. Genotype 3 comprised four deer-derived sequences, whereas genotype 4 included nine sequences from deer, mouse, chipmunk, and muskrat samples. PCR analysis was performed on the SSU-positive fecal samples for three other Cryptosporidium loci (dihydrofolate reductase, polythreonine-rich protein, and beta-tubulin), and 8 of 10 cloned PCR products were consistent with C. parvum genotype 2. These data provide evidence that there is sylvatic transmission of C. parvum involving deer and other small mammals. This study affirmed the importance of wildlife as potential sources of Cryptosporidium in the catchments of public water supplies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rhee, Minsoung; Light, Yooli K.; Meagher, Robert J.
Here, multiple displacement amplification (MDA) is a widely used technique for amplification of DNA from samples containing limited amounts of DNA (e.g., uncultivable microbes or clinical samples) before whole genome sequencing. Despite its advantages of high yield and fidelity, it suffers from high amplification bias and non-specific amplification when amplifying sub-nanogram of template DNA. Here, we present a microfluidic digital droplet MDA (ddMDA) technique where partitioning of the template DNA into thousands of sub-nanoliter droplets, each containing a small number of DNA fragments, greatly reduces the competition among DNA fragments for primers and polymerase thereby greatly reducing amplification bias. Consequently,more » the ddMDA approach enabled a more uniform coverage of amplification over the entire length of the genome, with significantly lower bias and non-specific amplification than conventional MDA. For a sample containing 0.1 pg/μL of E. coli DNA (equivalent of ~3/1000 of an E. coli genome per droplet), ddMDA achieves a 65-fold increase in coverage in de novo assembly, and more than 20-fold increase in specificity (percentage of reads mapping to E. coli) compared to the conventional tube MDA. ddMDA offers a powerful method useful for many applications including medical diagnostics, forensics, and environmental microbiology.« less
Rhee, Minsoung; Light, Yooli K.; Meagher, Robert J.; ...
2016-05-04
Here, multiple displacement amplification (MDA) is a widely used technique for amplification of DNA from samples containing limited amounts of DNA (e.g., uncultivable microbes or clinical samples) before whole genome sequencing. Despite its advantages of high yield and fidelity, it suffers from high amplification bias and non-specific amplification when amplifying sub-nanogram of template DNA. Here, we present a microfluidic digital droplet MDA (ddMDA) technique where partitioning of the template DNA into thousands of sub-nanoliter droplets, each containing a small number of DNA fragments, greatly reduces the competition among DNA fragments for primers and polymerase thereby greatly reducing amplification bias. Consequently,more » the ddMDA approach enabled a more uniform coverage of amplification over the entire length of the genome, with significantly lower bias and non-specific amplification than conventional MDA. For a sample containing 0.1 pg/μL of E. coli DNA (equivalent of ~3/1000 of an E. coli genome per droplet), ddMDA achieves a 65-fold increase in coverage in de novo assembly, and more than 20-fold increase in specificity (percentage of reads mapping to E. coli) compared to the conventional tube MDA. ddMDA offers a powerful method useful for many applications including medical diagnostics, forensics, and environmental microbiology.« less
Thornberg, Steven M [Peralta, NM
2012-07-31
A system is provided for testing the hermeticity of a package, such as a microelectromechanical systems package containing a sealed gas volume, with a sampling device that has the capability to isolate the package and breach the gas seal connected to a pulse valve that can controllably transmit small volumes down to 2 nanoliters to a gas chamber for analysis using gas chromatography/mass spectroscopy diagnostics.
NASA Astrophysics Data System (ADS)
Xu, Jiajie; Jiang, Bo; Chai, Sanming; He, Yuan; Zhu, Jianyi; Shen, Zonggen; Shen, Songdong
2016-09-01
Filamentous Bangia, which are distributed extensively throughout the world, have simple and similar morphological characteristics. Scientists can classify these organisms using molecular markers in combination with morphology. We successfully sequenced the complete nuclear ribosomal DNA, approximately 13 kb in length, from a marine Bangia population. We further analyzed the small subunit ribosomal DNA gene (nrSSU) and the internal transcribed spacer (ITS) sequence regions along with nine other marine, and two freshwater Bangia samples from China. Pairwise distances of the nrSSU and 5.8S ribosomal DNA gene sequences show the marine samples grouping together with low divergences (00.003; 0-0.006, respectively) from each other, but high divergences (0.123-0.126; 0.198, respectively) from freshwater samples. An exception is the marine sample collected from Weihai, which shows high divergence from both other marine samples (0.063-0.065; 0.129, respectively) and the freshwater samples (0.097; 0.120, respectively). A maximum likelihood phylogenetic tree based on a combined SSU-ITS dataset with maximum likelihood method shows the samples divided into three clades, with the two marine sample clades containing Bangia spp. from North America, Europe, Asia, and Australia; and one freshwater clade, containing Bangia atropurpurea from North America and China.
Improvement of core drill methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gatz, J.L.
1975-07-01
This report documents results of a program to evaluate effectiveness of more or less conventional subsurface samplers in obtaining representative and undisturbed samples of noncohesive alluvial materials containing large quantities of gravels and cobbles. This is the first phase of a research program to improve core drill methods. Samplers evaluated consisted of the Lawrence Livermore Laboratory membrane sampler, 4-in. Denison sampler, 6-in. Dension sampler, 5-in. Modified Denison sampler, and 3-in. thinwall drive tube. Small representative samples were obtained with the Dension samplers; no undisturbed samples were obtained. The field work was accomplished in the Rhodes Canyon area, White Sands Misslemore » Range, New Mexico.« less
Mitsuoka, Motoki; Shinzawa, Hideyuki; Morisawa, Yusuke; Kariyama, Naomi; Higashi, Noboru; Tsuboi, Motohiro; Ozaki, Yukihiro
2011-01-01
Far-ultraviolet (FUV) spectra in the 190-300 nm region were measured for spring water in Awaji-Akashi area, Tamba area and Rokko-Arima area in Hyogo Prefecture, Japan, these areas have quite different geology features. The spectra of the spring water in the Awaji-Akashi area can be divided into two groups: the spring water samples containing large amounts of NO(3)(-) and/or Cl(-), and those containing only small amounts of NO(3)(-) and Cl(-). The former shows a saturated band below 190 nm due to NO(3)(-) and/or Cl(-). These two types of spectra correspond to different lithological areas: sedimentary lithology near the sea shore containing many ions in the seawater and gravitic lithology far from the sea side, in the Awaji-Akashi area. The spring water from the Tamba area, which is far from the sea, contains relatively small amounts of NO(3)(-) and Cl(-); it does not yield a strong band in the region observed. The FUV spectra of three of four kinds of spring water samples in the Arima Hotspring show characteristic spectral patterns. They are quite different from the spectra of the spring water samples of the Rokko area. Calibration models were developed for NO(3)(-), Cl(-), SO(4)(2-), Na(+), and Mg(2+) in the nine kinds of spring water collected in the Awaji-Akashi area, Tamba, and Rokko-Arima area by using univariate analysis of the first derivative spectra and the actual values obtained by ion chromatography. NO(3)(-) yields the best results: correlation coefficient of 0.999 and standard deviation of 0.09 ppm with the wavelength of 212 nm. Cl(-) also gives good results: correlation coefficient of 0.993 and standard deviation of 0.5 ppm with the wavelength of 192 nm.
Kit for the rapid preparation of .sup.99m Tc red blood cells
Richards, Powell; Smith, Terry D.
1976-01-01
A method and sample kit for the preparation of .sup.99m Tc-labeled red blood cells in a closed, sterile system. A partially evacuated tube, containing a freeze-dried stannous citrate formulation with heparin as an anticoagulant, allows whole blood to be automatically drawn from the patient. The radioisotope is added at the end of the labeling sequence to minimize operator exposure. Consistent 97% yields in 20 minutes are obtained with small blood samples. Freeze-dried kits have remained stable after five months.
A displacement pump procedure to load extracts for automated gel permeation chromatography.
Daft, J; Hopper, M; Hensley, D; Sisk, R
1990-01-01
Automated gel permeation chromatography (GPC) effectively separates lipids from pesticides in sample extracts that contain fat. Using a large syringe to load sample extracts manually onto GPC models having 5 mL holding loops is awkward, slow, and potentially hazardous. Loading with a small-volume displacement pump, however, is convenient and fast (ca 1 loop every 20 s). And more importantly, the analyst is not exposed to toxic organic vapors because the loading pump and its connecting lines do not leak in the way that a syringe does.
Jiang, Gui-Yang; Zhang, Xiu-Peng; Zhang, Yong; Xu, Hong-Tao; Wang, Liang; Li, Qing-Chang; Wang, En-Hua
2016-10-01
Lung cancer has always been the leading cause of death among patients with malignant tumors, and the majority of these patients die because of cancer cell invasion and metastasis. Previous studies have implicated coiled-coil domain-containing protein 8 (CCDC8) as a tumor suppressor in several types of cancer, such as breast and prostate cancers. However, the expression levels or functions of CCDC8 in lung cancer have not been elucidated. Here, we used immunohistochemical staining to measure CCDC8 expression in 147 samples from tumors and 30 samples from the adjacent normal lung tissues of patients with non-small cell lung cancer. CCDC8 was shown to be located predominantly in the cytoplasm and partially on the cell membrane, and its expression level was significantly lower in lung cancer samples than that in the adjacent normal lung tissues (P=.001). CCDC8 expression was closely related to tumor differentiation (P=.039), tumor-node-metastasis stage (P=.009), lymph node metastasis (P=.038), and prognosis (P=.043) of lung cancer. Transfection of A549 cells with CCDC8 significantly reduced cell invasion and migration (P<.05), whereas the invasiveness and migration capacity in CCDC8-knockdown A549 cells were significantly increased in comparison with the control cells (P<.05). Furthermore, we demonstrated that CCDC8 can downregulate the expression of Snail and upregulate the expression of E-cadherin by inhibiting p-P38 and p-IκBα. Collectively, CCDC8 may suppress the invasion and metastasis of lung cancer cells, and it may represent a promising therapeutic target for non-small cell lung cancer. Copyright © 2016 Elsevier Inc. All rights reserved.
CANISTER TRANSFER SYSTEM DESCRIPTION DOCUMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
B. Gorpani
2000-06-23
The Canister Transfer System receives transportation casks containing large and small disposable canisters, unloads the canisters from the casks, stores the canisters as required, loads them into disposal containers (DCs), and prepares the empty casks for re-shipment. Cask unloading begins with cask inspection, sampling, and lid bolt removal operations. The cask lids are removed and the canisters are unloaded. Small canisters are loaded directly into a DC, or are stored until enough canisters are available to fill a DC. Large canisters are loaded directly into a DC. Transportation casks and related components are decontaminated as required, and empty casks aremore » prepared for re-shipment. One independent, remotely operated canister transfer line is provided in the Waste Handling Building System. The canister transfer line consists of a Cask Transport System, Cask Preparation System, Canister Handling System, Disposal Container Transport System, an off-normal canister handling cell with a transfer tunnel connecting the two cells, and Control and Tracking System. The Canister Transfer System operating sequence begins with moving transportation casks to the cask preparation area with the Cask Transport System. The Cask Preparation System prepares the cask for unloading and consists of cask preparation manipulator, cask inspection and sampling equipment, and decontamination equipment. The Canister Handling System unloads the canister(s) and places them into a DC. Handling equipment consists of a bridge crane hoist, DC loading manipulator, lifting fixtures, and small canister staging racks. Once the cask has been unloaded, the Cask Preparation System decontaminates the cask exterior and returns it to the Carrier/Cask Handling System via the Cask Transport System. After the DC is fully loaded, the Disposal Container Transport System moves the DC to the Disposal Container Handling System for welding. To handle off-normal canisters, a separate off-normal canister handling cell is located adjacent to the canister transfer cell and is interconnected to the transfer cell by means of the off-normal canister transfer tunnel. All canister transfer operations are controlled by the Control and Tracking System. The system interfaces with the Carrier/Cask Handling System for incoming and outgoing transportation casks. The system also interfaces with the Disposal Container Handling System, which prepares the DC for loading and subsequently seals the loaded DC. The system support interfaces are the Waste Handling Building System and other internal Waste Handling Building (WHB) support systems.« less
Parnell, Andrew J.; Hobson, Adam; Dalgliesh, Robert M.; Jones, Richard A. L.; Dunbar, Alan D. F.
2014-01-01
The spin echo resolved grazing incidence scattering (SERGIS) technique has been used to probe the length-scales associated with irregularly shaped crystallites. Neutrons are passed through two well defined regions of magnetic field; one before and one after the sample. The two magnetic field regions have opposite polarity and are tuned such that neutrons travelling through both regions, without being perturbed, will undergo the same number of precessions in opposing directions. In this case the neutron precession in the second arm is said to "echo" the first, and the original polarization of the beam is preserved. If the neutron interacts with a sample and scatters elastically the path through the second arm is not the same as the first and the original polarization is not recovered. Depolarization of the neutron beam is a highly sensitive probe at very small angles (<50 μrad) but still allows a high intensity, divergent beam to be used. The decrease in polarization of the beam reflected from the sample as compared to that from the reference sample can be directly related to structure within the sample. In comparison to scattering observed in neutron reflection measurements the SERGIS signals are often weak and are unlikely to be observed if the in-plane structures within the sample under investigation are dilute, disordered, small in size and polydisperse or the neutron scattering contrast is low. Therefore, good results will most likely be obtained using the SERGIS technique if the sample being measured consist of thin films on a flat substrate and contain scattering features that contains a high density of moderately sized features (30 nm to 5 µm) which scatter neutrons strongly or the features are arranged on a lattice. An advantage of the SERGIS technique is that it can probe structures in the plane of the sample. PMID:24457355
Aerosol emissions from forest and grassland burnings in the southern amazon basin and central Brazil
NASA Astrophysics Data System (ADS)
Leslie, Alistair C. D.
1981-03-01
Forest and grassland clearing by means of prescribed fires in tropical areas of the world may be responsible for large inputs of fine particulates to the global atmosphere besides being a major source of trace gases. The major continents on which extensive biomass burning takes place are Africa and South America. Such agricultural practices of burning have been employed throughout man's existence, but the importance and significance of such burning relative to anthropogenic industrial emissions to the atmosphere has not until extremely recently been seriously studied. In August-September 1979 project "Brushfire 1979" took place based in Brasília, Brazil. The Air Quality Division of the National Center for Atmospheric Research made ground level and aircraft measurements of trace gases (e.g. CO 2, CO, CH 4, N 2O, H 2, CH 3Cl, COS, NO, NO 2, O 3) and Florida State University sampled ground level aerosol emissions from grass and forest burnings. Aerosols were sampled using plastic 7-stage single orifice cascade impactors and FSU type linear and circular "streakers". Long term sampling was made of regional background for total particulates (<15 μmad) with 2 h resolution using streakers and with impactors for 24 h resolution of 7 particle size fractions (<0.25 to >8 μmad). Short term sampling within grass or forest fires was made using impactors incorporated into portable kits containing 4 miniature 12-18 V dc Brailsford pumps and a disposable dry cell power pack. Sampling times of 5-15 min were found optimal under these conditions. Grass fires were sampled in the savannah area northeast of Brasília and forest fires in the state of Mato Grosso on the southern edge of the dryland forest of the Amazon basin. Residual ash samples were collected. All of the samples were analyzed at Florida State University using PIXE for 15-20 elements including Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Pb and Sr. Computer reduction of the X-ray spectra was made using the "HEXB" program. One of the prominent features found was the large flux of small particles (<2.0 μm) from both fire types. P, S and Cl were mostly small particle, Mg, Al, Si and K showed a bimodal distribution biased towards the small particle range, while Ca, Ti and Fe (crustal elements) predominated in the large particle mode. As Cl was found to be exclusively small particle, a formation mechanism in which HCl gas neutralizes small organic particles containing P and S may be hypothesized. A much more extensive field program for the summer of 1980 is planned to take place in the central Amazon basin using ground and airborne aerosol samplers, to capitalize on the work pioneered in this study.
NASA Astrophysics Data System (ADS)
Turcu, Ioan; Bratfalean, Radu; Neamtu, Silvia
2008-07-01
The adequacy of the effective phase function (EPF) used to describe the light scattered at small angles was tested on aqueous suspensions of polystyrene microspheres. Angular resolved light scattering measurements were performed on two types of latex suspension, which contained polystyrene spheres of 3 µm and 5 µm diameters, respectively. The experimental data were fitted with two EPF approximants. If the polystyrene spheres are at least 3 µm in diameter the quasi-ballistic light scattering process can be described relatively well by the EPF in a small angular range centered in the forward direction. The forward light scattering by macroscopic samples containing microspheres can be modeled relatively well if the true Mie single particle scattering phase function is replaced by a simpler Henyey-Greenstein dependence having the same width at half-height as the first scattering lobe.
Magnetic properties of Apollo 14 breccias and their correlation with metamorphism.
NASA Technical Reports Server (NTRS)
Gose, W. A.; Pearce, G. W.; Strangway, D. W.; Larson, E. E.
1972-01-01
The magnetic properties of Apollo 14 breccias can be explained in terms of the grain size distribution of the interstitial iron which is directly related to the metamorphic grade of the sample. In samples 14049 and 14313 iron grains less than 500 A in diameter are dominant as evidenced by a Richter-type magnetic aftereffect and hysteresis measurements. Both samples are of lowest metamorphic grade. The medium metamorphic-grade sample 14321 and the high-grade sample 14312 both show a logarithmic time-dependence of the magnetization indicative of a wide range of relaxation times and thus grain sizes, but sample 14321 contains a stable remanent magnetization whereas sample 14312 does not. This suggests that small multidomain particles (less than 1 micron) are most abundant in sample 14321 while sample 14312 is magnetically controlled by grains greater than 1 micron. The higher the metamorphic grade, the larger the grain size of the iron controlling the magnetic properties.
Effective screening length of isotropic liquid samples submitted to an applied voltage.
Zola, R S; Evangelista, L R; Barbero, G
2006-05-25
A cell of isotropic liquid in the shape of a slab of thickness d and containing ionic impurities is considered. It is shown that the screening effect produced by the ionic charges on the external field is characterized by an effective surface length, lambda(S)(U), depending on the applied voltage U. The analysis indicates that lambda(S)(U)) < lambda(D) when the applied voltage is very large, and lambda(S)(U) --> lambda(D) for very small values of the applied voltage, where lambda(D) is the Debye screening length. The presence of the ions is responsible also for a counterpotential, v, that for small U is such to cancel the effective electric field in the sample, whereas in the opposite limit it is inversely proportional to the applied difference of potential.
COCAP: a carbon dioxide analyser for small unmanned aircraft systems
NASA Astrophysics Data System (ADS)
Kunz, Martin; Lavric, Jost V.; Gerbig, Christoph; Tans, Pieter; Neff, Don; Hummelgård, Christine; Martin, Hans; Rödjegård, Henrik; Wrenger, Burkhard; Heimann, Martin
2018-03-01
Unmanned aircraft systems (UASs) could provide a cost-effective way to close gaps in the observation of the carbon cycle, provided that small yet accurate analysers are available. We have developed a COmpact Carbon dioxide analyser for Airborne Platforms (COCAP). The accuracy of COCAP's carbon dioxide (CO2) measurements is ensured by calibration in an environmental chamber, regular calibration in the field and by chemical drying of sampled air. In addition, the package contains a lightweight thermal stabilisation system that reduces the influence of ambient temperature changes on the CO2 sensor by 2 orders of magnitude. During validation of COCAP's CO2 measurements in simulated and real flights we found a measurement error of 1.2 µmol mol-1 or better with no indication of bias. COCAP is a self-contained package that has proven well suited for the operation on board small UASs. Besides carbon dioxide dry air mole fraction it also measures air temperature, humidity and pressure. We describe the measurement system and our calibration strategy in detail to support others in tapping the potential of UASs for atmospheric trace gas measurements.
Delwart, Eric; Li, Linlin
2011-01-01
The genomes of numerous circoviruses and distantly related circular DNA viruses encoding a rolling circle replication initiator protein (Rep) have been characterized from the tissues of mammals, fish, insects, and plants (geminivirus and nanovirus), human and animal feces, in an algae cell, and in diverse environmental samples. We review the genome organization, phylogenetic relationships and initial prevalence studies of cycloviruses, a proposed new genus in the Circoviridae family. Viral fossil rep sequences were also identified integrated on the chromosomes of mammals, frogs, lancelets, crustaceans, mites, gastropods, roundworms, placozoans, hydrozoans, protozoans, land plants, fungi, algae, and phytoplasma bacterias and their plasmids, reflecting their past host range. An ancient origin for viruses with rep-encoding single stranded small circular genomes, predating the diversification of eukaryotes, is discussed. The cellular hosts and pathogenicity of many recently described rep-containing circular genomes remain to be determined. Future studies of the virome of single cell and multi-cellular eukaryotes are likely to further extend the known diversity and host-range of small rep-containing circular viral genomes. PMID:22155583
Patchanee, Prapas; Tadee, Pakpoom; Ingkaninan, Pimlada; Tankaew, Pallop; Hoet, Armando E; Chupia, Vena
2014-03-01
Of 416 samples taken from veterinary staff (n = 30), dogs (n = 356) and various environmental sites (n = 30) at the Small Animal Hospital, Faculty of Veterinary Medicine, Chiang Mai University, Thailand, 13 samples contained methicillin-resistant Staphylococcus aureus (MRSA), of which 1 (SCCmec type II) came from veterinarian, 9 (SCCmec types I, III, IVa, V and untypeable) from dogs, and 3 (SCCmec types I, III, and IVb) from environmental samples. The MRSA isolates were 100% susceptible to vancomycin (100%), 69% to cephazolin and 62% to gentamicin, but were up to 92% resistant to tetracycline group, 69% to trimethoprim-sulfamethoxazoles and 62% to ceftriaxone. In addition, all MRSA isolates showed multidrug resistance. As the MRSA isolates from the veterinary staff and dogs were of different SCCmec types, this suggests there were no cross-infections. However, environmental contamination appears to have come from dogs, and appropriate hygienic practices should be introduced to solve this problem.
Quality of water in the Trinity and Edwards aquifers, south-central Texas, 1996-98
Fahlquist, Lynne; Ardis, Ann F.
2004-01-01
During 1996–98, the U.S. Geological Survey studied surface- and ground-water quality in south-central Texas. The ground-water components included the upper and middle zones (undifferentiated) of the Trinity aquifer in the Hill Country and the unconfined part (recharge zone) and confined part (artesian zone) of the Edwards aquifer in the Balcones fault zone of the San Antonio region. The study was supplemented by information compiled from four ground-water-quality studies done during 1996–98.Trinity aquifer waters are more mineralized and contain larger dissolved solids, sulfate, and chloride concentrations compared to Edwards aquifer waters. Greater variability in water chemistry in the Trinity aquifer likely reflects the more variable lithology of the host rock. Trace elements were widely detected, mostly at small concentrations. Median total nitrogen was larger in the Edwards aquifer than in the Trinity aquifer. Ammonia nitrogen was detected more frequently and at larger concentrations in the Trinity aquifer than in the Edwards aquifer. Although some nitrate nitrogen concentrations in the Edwards aquifer exceeded a U.S. Geological Survey national background threshold concentration, no concentrations exceeded the U.S. Environmental Protection Agency public drinking-water standard.Synthetic organic compounds, such as pesticides and volatile organic compounds, were detected in the Edwards aquifer and less frequently in the Trinity aquifer, mostly at very small concentrations (less than 1 microgram per liter). These compounds were detected most frequently in urban unconfined Edwards aquifer samples. Atrazine and its breakdown product deethylatrazine were the most frequently detected pesticides, and trihalomethanes were the most frequently detected volatile organic compounds. Widespread detections of these compounds, although at small concentrations, indicate that anthropogenic activities affect ground-water quality.Radon gas was detected throughout the Trinity aquifer but not throughout the Edwards aquifer. Fourteen samples from the Trinity aquifer and 10 samples from the Edwards aquifer exceeded a proposed U.S. Environmental Protection Agency public drinking-water standard. Sources of radon in the study area might be granitic sediments underlying the Trinity aquifer and igneous intrusions in and below the Edwards aquifer.The presence of tritium in nearly all Edwards aquifer samples indicates that some component of sampled water is young (less than about 50 years), even for long flow paths in the confined zone. About one-half of the Trinity aquifer samples contained tritium, indicating that only part of the aquifer contains young water.Hydrogen and oxygen isotopes of water provide indicators of recharge sources to the Trinity and Edwards aquifers. Most ground-water samples have a meteorological isotopic signature indicating recharge as direct infiltration of water with little residence time on the land surface. Isotopic data from some samples collected from the unconfined Edwards aquifer indicate the water has undergone evaporation. At the time that ground-water samples were collected (during a drought), nearby streams were the likely sources of recharge to these wells.
Reversible Cryopreservation of Living Cells Using an Electron Microscopy Cryo-Fixation Method.
Huebinger, Jan; Han, Hong-Mei; Grabenbauer, Markus
2016-01-01
Rapid cooling of aqueous solutions is a useful approach for two important biological applications: (I) cryopreservation of cells and tissues for long-term storage, and (II) cryofixation for ultrastructural investigations by electron and cryo-electron microscopy. Usually, both approaches are very different in methodology. Here we show that a novel, fast and easy to use cryofixation technique called self-pressurized rapid freezing (SPRF) is-after some adaptations-also a useful and versatile technique for cryopreservation. Sealed metal tubes with high thermal diffusivity containing the samples are plunged into liquid cryogen. Internal pressure builds up reducing ice crystal formation and therefore supporting reversible cryopreservation through vitrification of cells. After rapid rewarming of pressurized samples, viability rates of > 90% can be reached, comparable to best-performing of the established rapid cooling devices tested. In addition, the small SPRF tubes allow for space-saving sample storage and the sealed containers prevent contamination from or into the cryogen during freezing, storage, or thawing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walls, P
Sixteen of the twenty-one samples have been investigated using the scanning laser dilatometer. This includes all three types of samples with different preparation routes and organic content. Cracks were observed in all samples, even those only heated to 300 C. It was concluded that the cracking was occurring in the early part of the heat treatment before the samples reached 300 C. Increase in the rate of dilation of the samples occurred above 170 C which coincided with the decomposition of the binder/wax additives as determined by differential thermal analysis. A comparison was made with SYNROC C material (Powder Runmore » 143), samples of which had been CIPed and green machined to a similar diameter and thickness as the 089mm SRTC pucks. These samples contained neither binder nor other organic processing aids and had been kept in the same desiccator as the SRTC samples. The CIPed Synroc C samples sintered to high density with zero cracks. As the cracks made up only a small contribution to the change in diameter of the sample compared to the sintering shrinkage, useful information could still be gained from the runs. The sintering curves showed that there was much greater shrinkage of the Type III samples containing only the 5% PEG binder compared to the Type I which contained polyolefin wax as processing aid. Slight changes in gradient of the sintering curve were observed, however, due to the masking effect of the cracking, full analysis of the sintering kinetics cannot be conducted. Even heating the samples to 300 C at 1.0 or 0.5 C/min could not prevent crack formation. This indicated that heating rate was not the critical parameter causing cracking of the samples. Sectioning of green bodies revealed the inhomogeneous nature of the binder/lubricant distribution in the samples. Increased homogeneity would reduce the amount of binder/lubricant required, which should in turn, reduce the degree of cracking observed during heating to the binder burnout temperature. A combination of: (1) use of a higher forming pressure, (2) reduction of organics content, (3) improvement in the distribution of the organic wax and binder components throughout the green body, could possibly alleviate cracking. Ultrasonic emulsification of the binder and wax with a small quantity of water prior to adding to the ball or attrition mill is advised to ensure more even distribution of the wax/binder system. This would also reduce the proportion of organic additives required. The binder burnout stage of the operation must first be optimized (i.e. production of pucks with no cracks) prior to optimization of the sintering stage.« less
Johanson, Gunnar
2017-01-01
Abstract Containerized cargo shipment makes up the backbone of international trade. The principal aim of this cross-sectional study was to establish a qualitative and quantitative description of gaseous fumigants and volatile off-gassing substances facing workers tasked with entering shipping containers. A total of 372 packed and 119 empty shipping containers were sampled in six ports and two distribution centers in Sweden. Fourier-transform infrared spectrometry (FTIR) and photoionization detection (PID) were the analytical methods applied to the bulk of samples. A small number of adsorbent samples were analyzed using gas chromatography–mass spectrometry (GC–MS). The results were compared to Swedish occupational exposure limits (OELs), the closest parallel to relevant work situations. Based on the FTIR analyses, 30 of 249 (12%) containers arrived with concentrations of fumigants and off-gassing substances above the 8-h OELs and close to 7% were above the short-term exposure limits. Eight detected chemicals were classified as carcinogens and 4% of the containers arrived with levels of carcinogens above the OELs, at a maximum 30 times the 8-h OEL. Considerable differences were observed between ports, ranging from 0 to 33% of containers arriving with concentrations above the OELs. It is believed that all observation results, apart from a single instance of a confirmed fumigant, phosphine, at 3 p.p.m., and possibly three instances of carbon dioxide, can be attributed to off-gassing substances. The FTIR methodology proved useful for quick preliminary checks and in-depth screening and identification. The PID method produced both false-negative and false-positive results where only 48% matched the FTIR observations. Adsorbent sampling with GC–MS analysis was useful for confirming volatile organic compounds but was deemed too slow for day-to-day screening. The high frequency of contaminated containers, the detection of several carcinogens, and the sporadic occurrences of high levels of fumigants are serious concerns that need to be properly recognized in order to protect the workers at risk. PMID:28395344
MARCO POLO: near earth object sample return mission
NASA Astrophysics Data System (ADS)
Barucci, M. A.; Yoshikawa, M.; Michel, P.; Kawagushi, J.; Yano, H.; Brucato, J. R.; Franchi, I. A.; Dotto, E.; Fulchignoni, M.; Ulamec, S.
2009-03-01
MARCO POLO is a joint European-Japanese sample return mission to a Near-Earth Object. This Euro-Asian mission will go to a primitive Near-Earth Object (NEO), which we anticipate will contain primitive materials without any known meteorite analogue, scientifically characterize it at multiple scales, and bring samples back to Earth for detailed scientific investigation. Small bodies, as primitive leftover building blocks of the Solar System formation process, offer important clues to the chemical mixture from which the planets formed some 4.6 billion years ago. Current exobiological scenarios for the origin of Life invoke an exogenous delivery of organic matter to the early Earth: it has been proposed that primitive bodies could have brought these complex organic molecules capable of triggering the pre-biotic synthesis of biochemical compounds. Moreover, collisions of NEOs with the Earth pose a finite hazard to life. For all these reasons, the exploration of such objects is particularly interesting and urgent. The scientific objectives of MARCO POLO will therefore contribute to a better understanding of the origin and evolution of the Solar System, the Earth, and possibly Life itself. Moreover, MARCO POLO provides important information on the volatile-rich (e.g. water) nature of primitive NEOs, which may be particularly important for future space resource utilization as well as providing critical information for the security of Earth. MARCO POLO is a proposal offering several options, leading to great flexibility in the actual implementation. The baseline mission scenario is based on a launch with a Soyuz-type launcher and consists of a Mother Spacecraft (MSC) carrying a possible Lander named SIFNOS, small hoppers, sampling devices, a re-entry capsule and scientific payloads. The MSC leaves Earth orbit, cruises toward the target with ion engines, rendezvous with the target, conducts a global characterization of the target to select a sampling site, and delivers small hoppers (MINERVA type, JAXA) and SIFNOS. The latter, if added, will perform a soft landing, anchor to the target surface, and make various in situ measurements of surface/subsurface materials near the sampling site. Two surface samples will be collected by the MSC using “touch and go” manoeuvres. Two complementary sample collection devices will be used in this phase: one developed by ESA and another provided by JAXA, mounted on a retractable extension arm. After the completion of the sampling and ascent of the MSC, the arm will be retracted to transfer the sample containers into the MSC. The MSC will then make its journey back to Earth and release the re-entry capsule into the Earth’s atmosphere.
NASA Technical Reports Server (NTRS)
1981-01-01
The purpose of the Orbiting Quarantine Facility is to provide maximum protection of the terrestrial biosphere by ensuring that the returned Martian samples are safe to bring to Earth. The protocol designed to detect the presence of biologically active agents in the Martian soil is described. The protocol determines one of two things about the sample: (1) that it is free from nonterrestrial life forms and can be sent to a terrestrial containment facility where extensive chemical, biochemical, geological, and physical investigations can be conducted; or (2) that it exhibits "biological effects" of the type that dictate second order testing. The quarantine protocol is designed to be conducted on a small portion of the returned sample, leaving the bulk of the sample undisturbed for study on Earth.
NASA Astrophysics Data System (ADS)
Roether, Wolfgang; Vogt, Martin; Vogel, Sandra; Sültenfuß, Jürgen
2013-06-01
We present a new method to obtain samples for the measurement of helium isotopes and neon in water, to replace the classical sampling procedure using clamped-off Cu tubing containers that we have been using so far. The new method saves the gas extraction step prior to admission to the mass spectrometer, which the classical method requires. Water is drawn into evacuated glass ampoules with subsequent flame sealing. Approximately 50% headspace is left, from which admission into the mass spectrometer occurs without further treatment. Extensive testing has shown that, with due care and with small corrections applied, the samples represent the gas concentrations in the water within ±0.07% (95% confidence level; ±0.05% with special handling). Fast evacuation is achieved by pumping on a small charge of water placed in the ampoule. The new method was successfully tested at sea in comparison with Cu-tubing sampling. We found that the ampoule samples were superior in data precision and that a lower percentage of samples were lost prior to measurement. Further measurements revealed agreement between the two methods in helium, 3He and neon within ±0.1%. The new method facilitates the dealing with large sample sets and minimizes the delay between sampling and measurement. The method is applicable also for gases other than helium and neon.
Vehicle and cargo inspection system
NASA Astrophysics Data System (ADS)
Verbinski, Victor V.; Orphan, Victor J.
1997-02-01
Vehicle and Cargo Inspection System (VACIS) is comprised of a 1 Curie 137Cs gamma-ray source in a shield and collimator which produces a fan-shaped beam designed to intercept a vertical array of gama-ray detectors contained in a tower structure. The source and detector modules straddle the vehicle or container being inspected and are mounted on self-propelled trolleys which travel in synchronization along two parallel tracks covering the length of the scanned object. The signals from the gamma-ray detector array are processed and displayed so as to produce a 2D gamma-radiographic image of the object. Testing of the system on a variety of empty and lightly-loaded vehicles and containers has demonstrated the effectiveness of VACIS in detecting hidden contraband. For example, a small sample of cocaine only 1.5 inches thick was readily detected in a container.
Valenti, Daniela; de Bari, Lidia; De Filippis, Bianca; Ricceri, Laura; Vacca, Rosa Anna
2014-01-01
Studies of mitochondrial bioenergetics in brain pathophysiology are often precluded by the need to isolate mitochondria immediately after tissue dissection from a large number of brain biopsies for comparative studies. Here we present a procedure of cryopreservation of small brain areas from which mitochondrial enriched fractions (crude mitochondria) with high oxidative phosphorylation efficiency can be isolated. Small mouse brain areas were frozen and stored in a solution containing glycerol as cryoprotectant. Crude mitochondria were isolated by differential centrifugation from both cryopreserved and freshly explanted brain samples and were compared with respect to their ability to generate membrane potential and produce ATP. Intactness of outer and inner mitochondrial membranes was verified by polarographic ascorbate and cytochrome c tests and spectrophotometric assay of citrate synthase activity. Preservation of structural integrity and oxidative phosphorylation efficiency was successfully obtained in crude mitochondria isolated from different areas of cryopreserved mouse brain samples. Long-term cryopreservation of small brain areas from which intact and phosphorylating mitochondria can be isolated for the study of mitochondrial bioenergetics will significantly expand the study of mitochondrial defects in neurological pathologies, allowing large comparative studies and favoring interlaboratory and interdisciplinary analyses. Copyright © 2013 Elsevier Inc. All rights reserved.
Comparing interval estimates for small sample ordinal CFA models
Natesan, Prathiba
2015-01-01
Robust maximum likelihood (RML) and asymptotically generalized least squares (AGLS) methods have been recommended for fitting ordinal structural equation models. Studies show that some of these methods underestimate standard errors. However, these studies have not investigated the coverage and bias of interval estimates. An estimate with a reasonable standard error could still be severely biased. This can only be known by systematically investigating the interval estimates. The present study compares Bayesian, RML, and AGLS interval estimates of factor correlations in ordinal confirmatory factor analysis models (CFA) for small sample data. Six sample sizes, 3 factor correlations, and 2 factor score distributions (multivariate normal and multivariate mildly skewed) were studied. Two Bayesian prior specifications, informative and relatively less informative were studied. Undercoverage of confidence intervals and underestimation of standard errors was common in non-Bayesian methods. Underestimated standard errors may lead to inflated Type-I error rates. Non-Bayesian intervals were more positive biased than negatively biased, that is, most intervals that did not contain the true value were greater than the true value. Some non-Bayesian methods had non-converging and inadmissible solutions for small samples and non-normal data. Bayesian empirical standard error estimates for informative and relatively less informative priors were closer to the average standard errors of the estimates. The coverage of Bayesian credibility intervals was closer to what was expected with overcoverage in a few cases. Although some Bayesian credibility intervals were wider, they reflected the nature of statistical uncertainty that comes with the data (e.g., small sample). Bayesian point estimates were also more accurate than non-Bayesian estimates. The results illustrate the importance of analyzing coverage and bias of interval estimates, and how ignoring interval estimates can be misleading. Therefore, editors and policymakers should continue to emphasize the inclusion of interval estimates in research. PMID:26579002
Comparing interval estimates for small sample ordinal CFA models.
Natesan, Prathiba
2015-01-01
Robust maximum likelihood (RML) and asymptotically generalized least squares (AGLS) methods have been recommended for fitting ordinal structural equation models. Studies show that some of these methods underestimate standard errors. However, these studies have not investigated the coverage and bias of interval estimates. An estimate with a reasonable standard error could still be severely biased. This can only be known by systematically investigating the interval estimates. The present study compares Bayesian, RML, and AGLS interval estimates of factor correlations in ordinal confirmatory factor analysis models (CFA) for small sample data. Six sample sizes, 3 factor correlations, and 2 factor score distributions (multivariate normal and multivariate mildly skewed) were studied. Two Bayesian prior specifications, informative and relatively less informative were studied. Undercoverage of confidence intervals and underestimation of standard errors was common in non-Bayesian methods. Underestimated standard errors may lead to inflated Type-I error rates. Non-Bayesian intervals were more positive biased than negatively biased, that is, most intervals that did not contain the true value were greater than the true value. Some non-Bayesian methods had non-converging and inadmissible solutions for small samples and non-normal data. Bayesian empirical standard error estimates for informative and relatively less informative priors were closer to the average standard errors of the estimates. The coverage of Bayesian credibility intervals was closer to what was expected with overcoverage in a few cases. Although some Bayesian credibility intervals were wider, they reflected the nature of statistical uncertainty that comes with the data (e.g., small sample). Bayesian point estimates were also more accurate than non-Bayesian estimates. The results illustrate the importance of analyzing coverage and bias of interval estimates, and how ignoring interval estimates can be misleading. Therefore, editors and policymakers should continue to emphasize the inclusion of interval estimates in research.
Methodological considerations for measuring glucocorticoid metabolites in feathers
Berk, Sara A.; McGettrick, Julie R.; Hansen, Warren K.; Breuner, Creagh W.
2016-01-01
In recent years, researchers have begun to use corticosteroid metabolites in feathers (fCORT) as a metric of stress physiology in birds. However, there remain substantial questions about how to measure fCORT most accurately. Notably, small samples contain artificially high amounts of fCORT per millimetre of feather (the small sample artefact). Furthermore, it appears that fCORT is correlated with circulating plasma corticosterone only when levels are artificially elevated by the use of corticosterone implants. Here, we used several approaches to address current methodological issues with the measurement of fCORT. First, we verified that the small sample artefact exists across species and feather types. Second, we attempted to correct for this effect by increasing the amount of methanol relative to the amount of feather during extraction. We consistently detected more fCORT per millimetre or per milligram of feather in small samples than in large samples even when we adjusted methanol:feather concentrations. We also used high-performance liquid chromatography to identify hormone metabolites present in feathers and measured the reactivity of these metabolites against the most commonly used antibody for measuring fCORT. We verified that our antibody is mainly identifying corticosterone (CORT) in feathers, but other metabolites have significant cross-reactivity. Lastly, we measured faecal glucocorticoid metabolites in house sparrows and correlated these measurements with corticosteroid metabolites deposited in concurrently grown feathers; we found no correlation between faecal glucocorticoid metabolites and fCORT. We suggest that researchers should be cautious in their interpretation of fCORT in wild birds and should seek alternative validation methods to examine species-specific relationships between environmental challenges and fCORT. PMID:27335650
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berry, Jonna Elizabeth
This dissertation describes a variety of studies on the determination of trace elements in samples with forensic importance. Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) was used to determine the trace element composition of numerous lipstick samples. Lipstick samples were determined to be homogeneous. Most lipstick samples of similar colors were readily distinguishable at a 95% confidence interval based on trace element composition. Numerous strands of a multi-strand speaker cable were analyzed by LA-ICP-MS. The strands in this study are spatially heterogeneous in trace element composition. In actual forensic applications, the possibility of spatial heterogeneity must be considered, especially in casesmore » where only small samples (e.g., copper wire fragments after an explosion) are available. The effects of many unpredictable variables, such as weather, temperature, and human activity, on the retention of gunshot residue (GSR) around projectile wounds were assessed with LAICP- MS. Skin samples around gunshot and stab wounds and larvae feeding in and around the wounds on decomposing pig carcasses were analyzed for elements consistent with GSR (Sb, Pb, Ba, and Cu). These elements were detected at higher levels in skin and larvae samples around the gunshot wounds compared to the stab wounds for an extended period of time throughout decomposition in both a winter and summer study. After decomposition, radiographic images of the pig bones containing possible damage from bullets revealed metallic particles embedded within a number of bones. Metallic particles within the bones were analyzed with x-ray, K-edge densitometry and determined to contain lead, indicating that bullet residue can be retained throughout decomposition and detected within bones containing projectile trauma.« less
Boehm, Paul D; Page, David S; Brown, John S; Neff, Jerry M; Bragg, James R; Atlas, Ronald M
2008-12-15
In 2007, a systematic study was conducted to evaluate the form and location of residues of oil buried on Prince William Sound (PWS) shorelines, 18 years after the 1989 Exxon Valdez Oil Spill (EVOS). We took 678 sediment samples from 22 sites that were most heavily oiled in 1989 and known to contain the heaviest subsurface oil (SSO) deposits based on multiple studies conducted since 2001. An additional 66 samples were taken from two sites, both heavily oiled in 1989 and known to be active otter foraging sites. All samples were analyzed for total extractable hydrocarbons (TEH), and 25% were also analyzed for saturated and aromatic hydrocarbon weathering parameters. Over 90% of the samples from all sites contained light or no SSO at all. Of samples containing SSO, 81% showed total polycyclic aromatic hydrocarbon (TPAH) losses greater than 70%, relative to cargo oil, with most having >80% loss. Samples with SSO were observed in isolated patches sequestered by surface boulder and cobble armoring. Samples showing lowest TPAH loss correlated strongly with higher elevations in the intertidal zones. Of the 17 atypical, less-weathered samples having less than 70% loss of TPAH (>30% remaining), only two were found sequestered in the lower intertidal zone, both at a single site. Most of the EVOS oil in PWS has been eliminated due to natural weathering. Some isolated SSO residues remain because they are sequestered and only slowly affected by natural weathering processes that normally would bring about their rapid removal. Even where SSO patches remain, most are highly weathered, sporadically distributed at a small number of sites, and widely separated from biologically productive lower intertidal zones where most foraging by wildlife occurs.
NASA Astrophysics Data System (ADS)
Lu, Xin-Ming
Shallow junction formation made by low energy ion implantation and rapid thermal annealing is facing a major challenge for ULSI (ultra large scale integration) as the line width decreases down to the sub micrometer region. The issues include low beam current, the channeling effect in low energy ion implantation and TED (transient enhanced diffusion) during annealing after ion implantation. In this work, boron containing small cluster ions, such as GeB, SiB and SiB2, was generated by using the SNICS (source of negative ion by cesium sputtering) ion source to implant into Si substrates to form shallow junctions. The use of boron containing cluster ions effectively reduces the boron energy while keeping the energy of the cluster ion beam at a high level. At the same time, it reduces the channeling effect due to amorphization by co-implanted heavy atoms like Ge and Si. Cluster ions have been used to produce 0.65--2keV boron for low energy ion implantation. Two stage annealing, which is a combination of low temperature (550°C) preannealing and high temperature annealing (1000°C), was carried out to anneal the Si sample implanted by GeB, SiBn clusters. The key concept of two-step annealing, that is, the separation of crystal regrowth, point defects removal with dopant activation from dopant diffusion, is discussed in detail. The advantages of the two stage annealing include better lattice structure, better dopant activation and retarded boron diffusion. The junction depth of the two stage annealed GeB sample was only half that of the one-step annealed sample, indicating that TED was suppressed by two stage annealing. Junction depths as small as 30 nm have been achieved by two stage annealing of sample implanted with 5 x 10-4/cm2 of 5 keV GeB at 1000°C for 1 second. The samples were evaluated by SIMS (secondary ion mass spectrometry) profiling, TEM (transmission electron microscopy) and RBS (Rutherford Backscattering Spectrometry)/channeling. Cluster ion implantation in combination with two-step annealing is effective in fabricating ultra-shallow junctions.
Ground-water quality beneath irrigated agriculture in the central High Plains aquifer, 1999-2000
Bruce, Breton W.; Becker, Mark F.; Pope, Larry M.; Gurdak, Jason J.
2003-01-01
In 1999 and 2000, 30 water-quality monitoring wells were installed in the central High Plains aquifer to evaluate the quality of recently recharged ground water in areas of irrigated agriculture and to identify the factors affecting ground-water quality. Wells were installed adjacent to irrigated agricultural fields with 10- or 20-foot screened intervals placed near the water table. Each well was sampled once for about 100 waterquality constituents associated with agricultural practices. Water samples from 70 percent of the wells (21 of 30 sites) contained nitrate concentrations larger than expected background concentrations (about 3 mg/L as N) and detectable pesticides. Atrazine or its metabolite, deethylatrazine, were detected with greater frequency than other pesticides and were present in all 21 samples where pesticides were detected. The 21 samples with detectable pesticides also contained tritium concentrations large enough to indicate that at least some part of the water sample had been recharged within about the last 50 years. These 21 ground-water samples are considered to show water-quality effects related to irrigated agriculture. The remaining 9 groundwater samples contained no pesticides, small tritium concentrations, and nitrate concentrations less than 3.45 milligrams per liter as nitrogen. These samples are considered unaffected by the irrigated agricultural land-use setting. Nitrogen isotope ratios indicate that commercial fertilizer was the dominant source of nitrate in 13 of the 21 samples affected by irrigated agriculture. Nitrogen isotope ratios for 4 of these 21 samples were indicative of an animal waste source. Dissolved-solids concentrations were larger in samples affected by irrigated agriculture, with large sulfate concentrations having strong correlation with large dissolved solids concentrations in these samples. A strong statistical correlation is shown between samples affected by irrigated agriculture and sites with large rates of pesticide and nitrogen applications and shallow depths to ground water.
The search for asbestos within the Peter Mitchell Taconite iron ore mine, near Babbitt, Minnesota.
Ross, Malcolm; Nolan, Robert P; Nord, Gordon L
2008-10-01
Asbestos crystallizes within rock formations undergoing intense deformation characterized by folding, faulting, shearing, and dilation. Some of these conditions have prevailed during formation of the taconite iron ore deposits in the eastern Mesabi Iron Range of Minnesota. This range includes the Peter Mitchell Taconite Mine at Babbitt, Minnesota. The mine pit is over 8 miles long, up to 1 mile wide. Fifty three samples were collected from 30 sites within areas of the pit where faulting, shearing and folding occur and where fibrous minerals might occur. Eight samples from seven collecting sites contain significant amounts of ferroactinolite amphibole that is partially to completely altered to fibrous ferroactinolite. Two samples from two other sites contain ferroactinolite degraded to ropy masses of fibers consisting mostly of ferrian sepiolite as defined by X-ray diffraction and TEM and SEM X-ray spectral analysis. Samples from five other sites contain unaltered amphiboles, however some of these samples also contain a very small number of fiber bundles composed of mixtures of grunerite, ferroactinolite, and ferrian sepiolite. It is proposed that the alteration of the amphiboles was caused by reaction with water-rich acidic fluids that moved through the mine faults and shear zones. The fibrous amphiboles and ferrian sepiolite collected at the Peter Mitchell Mine composes a tiny fraction of one percent of the total rock mass of this taconite deposit; an even a smaller amount of these mineral fragments enter the ambient air during mining and milling. These fibrous minerals thus do not present a significant health hazard to the miners nor to those non-occupationally exposed. No asbestos of any type was found in the mine pit.
The polyphenolic profiles of common bean (Phaseolus vulgaris L.).
Lin, Long-Ze; Harnly, James M; Pastor-Corrales, Marcial S; Luthria, Devanand L
2008-03-01
Based on the phenolic profiles obtained by high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-DAD-ESI/MS), 24 common bean samples, representing 17 varieties and 7 generic off-the-shelf items, belonging to ten US commercial market classes can be organized into six different groups. All of them contained the same hydroxycinnaminic acids, but the flavonoid components showed distinct differences. Black beans contained primarily the 3- O -glucosides of delphinidin, petunidin and malvidin, while pinto beans contained kaempferol and its 3- O -glycosides. Light red kidney bean contained traces of quercetin 3- O -glucoside and its malonates, but pink and dark red kidney beans contained the diglycosides of quercetin and kaempferol. Small red beans contained kaempferol 3- O -glucoside and pelargonidin 3- O -glucoside, while no flavonoids were detected in alubia, cranberry, great northern, and navy beans. This is the first report of the tentative identification of quercetin 3- O -pentosylhexoside and flavonoid glucoside malonates, and the first detailed detection of hydroxycinnamates, in common beans.
Differential expression analysis for RNAseq using Poisson mixed models
Sun, Shiquan; Hood, Michelle; Scott, Laura; Peng, Qinke; Mukherjee, Sayan; Tung, Jenny
2017-01-01
Abstract Identifying differentially expressed (DE) genes from RNA sequencing (RNAseq) studies is among the most common analyses in genomics. However, RNAseq DE analysis presents several statistical and computational challenges, including over-dispersed read counts and, in some settings, sample non-independence. Previous count-based methods rely on simple hierarchical Poisson models (e.g. negative binomial) to model independent over-dispersion, but do not account for sample non-independence due to relatedness, population structure and/or hidden confounders. Here, we present a Poisson mixed model with two random effects terms that account for both independent over-dispersion and sample non-independence. We also develop a scalable sampling-based inference algorithm using a latent variable representation of the Poisson distribution. With simulations, we show that our method properly controls for type I error and is generally more powerful than other widely used approaches, except in small samples (n <15) with other unfavorable properties (e.g. small effect sizes). We also apply our method to three real datasets that contain related individuals, population stratification or hidden confounders. Our results show that our method increases power in all three data compared to other approaches, though the power gain is smallest in the smallest sample (n = 6). Our method is implemented in MACAU, freely available at www.xzlab.org/software.html. PMID:28369632
Subsurface Sample Acquisition and Transfer Systems (SSATS)
NASA Astrophysics Data System (ADS)
Rafeek, S.; Gorevan, S. P.; Kong, K. Y.
2001-01-01
In the exploration of planets and small bodies, scientists will need the services of a deep drilling and material handling system to not only obtain the samples necessary for analyses but also to precisely transfer and deposit those samples in in-situ instruments on board a landed craft or rover. The technology for such a deep sampling system as the SSATS is currently been developed by Honeybee Robotics through a PIDDP effort. The SSATS has its foundation in a one-meter prototype (SATM) drill that was developed under the New Millenium Program for ST4/Champollion. Additionally the SSATS includes relevant coring technology form a coring drill (Athena Mini-Corer) developed for the Mars Sample Return Mission. These highly developed technologies along with the current PIDDP effort, is combined to produce a sampling system that can acquire and transfer samples from various depths. Additional information is contained in the original extended abstract.
Whole Grains Contribute Only a Small Proportion of Dietary Fiber to the U.S. Diet
Kranz, Sibylle; Dodd, Kevin W.; Juan, Wen Yen; Johnson, LuAnn K.; Jahns, Lisa
2017-01-01
Dietary fiber (DF), found in whole fruits, vegetables, and whole grains (WG), is considered a nutrient of concern in the US diet and increased consumption is recommended. The present study was designed to highlight this critical importance of the difference between WG, high-fiber WG, and sources of fiber that are not from WG. The study is based on the two-day diets reported consumed by the nationally representative sample of Americans participating in What We Eat In America, the dietary component of the National Health and Nutrition Examination Survey from 2003–2010. Foods consumed were classified into tertiles of DF and WG and the contribution of fiber by differing levels of WG content were examined. Foods containing high amounts of WG and DF only contributed about 7% of total fiber intake. Overall, grain-based foods contributed 54.5% of all DF consumed. Approximately 39% of DF came from grain foods that contained no WG, rather these foods contained refined grains, which contain only small amounts of DF but are consumed in large quantities. All WG-containing foods combined contributed a total of 15.3% of DF in the American diet. Thus, public health messaging needs to be changed to specifically encourage consumption of WG foods with high levels of DF to address both recommendations. PMID:28218657
Helgerud, M.B.; Waite, W.F.; Kirby, S.H.; Nur, A.
2003-01-01
We report on laboratory measurements of compressional- and shear-wave speeds in a compacted, polycrystalline ice-Ih sample. The sample was made from triply distilled water that had been frozen into single crystal ice, ground into small grains, and sieved to extract the 180250 µm diameter fraction. Porosity was eliminated from the sample by compacting the granular ice between a hydraulically driven piston and a fixed end plug, both containing shear-wave transducers. Based on simultaneous compressional- and shear-wave-speed measurements, we calculated Poisson's ratio and compressional-wave, bulk, and shear moduli from 20 to 5°C and 22 to 33 MPa.
Clark, S.J.; Jackson, J.R.; Lochmann, S.E.
2007-01-01
We compared shoreline seines with fyke nets in terms of their ability to sample fish species in the littoral zone of 22 floodplain lakes of the White River, Arkansas. Lakes ranged in size from less than 0.5 to 51.0 ha. Most contained large amounts of coarse woody debris within the littoral zone, thus making seining in shallow areas difficult. We sampled large lakes (>2 ha) using three fyke nets; small lakes (<2 ha) were sampled using two fyke nets. Fyke nets were set for 24 h. Large lakes were sampled with an average of 11 seine hauls/ lake and small lakes were sampled with an average of 3 seine hauls/lake, but exact shoreline seining effort varied among lakes depending on the amount of open shoreline. Fyke nets collected more fish and produced greater species richness and diversity measures than did seining. Species evenness was similar for the two gear types. Two species were unique to seine samples, whereas 13 species and 3 families were unique to fyke-net samples. Although fyke nets collected more fish and more species than did shoreline seines, neither gear collected all the species present in the littoral zone of floodplain lakes. These results confirm the need for a multiple-gear approach to fully characterize the littoral fish assemblages in floodplain lakes. ?? Copyright by the American Fisheries Society 2007.
Sun, Keping; Kimball, Rebecca T.; Liu, Tong; Wei, Xuewen; Jin, Longru; Jiang, Tinglei; Lin, Aiqing; Feng, Jiang
2016-01-01
Palaeoclimatic oscillations and different landscapes frequently result in complex population-level structure or the evolution of cryptic species. Elucidating the potential mechanisms is vital to understanding speciation events. However, such complex evolutionary patterns have rarely been reported in bats. In China, the Rhinolophus macrotis complex contains a large form and a small form, suggesting the existence of a cryptic bat species. Our field surveys found these two sibling species have a continuous and widespread distribution with partial sympatry. However, their evolutionary history has received little attention. Here, we used extensive sampling, morphological and acoustic data, as well as different genetic markers to investigate their evolutionary history. Genetic analyses revealed discordance between the mitochondrial and nuclear data. Mitochondrial data identified three reciprocally monophyletic lineages: one representing all small forms from Southwest China, and the other two containing all large forms from Central and Southeast China, respectively. The large form showed paraphyly with respect to the small form. However, clustering analyses of microsatellite and Chd1 gene sequences support two divergent clusters separating the large form and the small form. Moreover, morphological and acoustic analyses were consistent with nuclear data. This unusual pattern in the R. macrotis complex might be accounted for by palaeoclimatic oscillations, shared ancestral polymorphism and/or interspecific hybridization. PMID:27748429
Packaging Considerations for Biopreservation
Woods, Erik J.; Thirumala, Sreedhar
2011-01-01
Summary The packaging system chosen for biopreservation is critical for many reasons. An ideal biopreservation container system must provide for closure integrity, sample stability and ready access to the preserved material. This means the system needs to be hermetically sealed to ensure integrity of the specimen is maintained throughout processing, storage and distribution; the system must remain stable over long periods of time as many biobanked samples may be stored indefinitely; and functionally closed access systems must be used to avoid contamination upon sample withdraw. This study reviews the suitability of a new commercially available vial configuration container utilizing blood bag style closure and access systems that can be hermetically sealed and remain stable through cryopreservation and biobanking procedures. This vial based systems allow for current good manufacturing/tissue practice (cGTP) requirements during processing of samples and may provide the benefit of ease of delivery by a care giver. In this study, the CellSeal® closed system cryovial was evaluated and compared to standard screw cap vials. The CellSeal system was evaluated for durability, closure integrity through transportation and maintenance of functional viability of a cryopreserved mesenchymal stem cell model. The results of this initial proof-of-concept study indicated that the CellSeal vials are highly suitable for biopreservation and biobanking, and provide a suitable container system for clinical and commercial cell therapy products frozen in small volumes. PMID:21566715
Respiratory analysis of coupled mitochondria in cryopreserved liver biopsies.
García-Roche, Mercedes; Casal, Alberto; Carriquiry, Mariana; Radi, Rafael; Quijano, Celia; Cassina, Adriana
2018-07-01
The aim of this work was to develop a cryopreservation method of small liver biopsies for in situ mitochondrial function assessment. Herein we describe a detailed protocol for tissue collection, cryopreservation, high-resolution respirometry using complex I and II substrates, calculation and interpretation of respiratory parameters. Liver biopsies from cow and rat were sequentially frozen in a medium containing dimethylsulfoxide as cryoprotectant and stored for up to 3 months at -80 °C. Oxygen consumption rate studies of fresh and cryopreserved samples revealed that most respiratory parameters remained unchanged. Additionally, outer mitochondrial membrane integrity was assessed adding cytochrome c, proving that our cryopreservation method does not harm mitochondrial structure. In sum, we present a reliable way to cryopreserve small liver biopsies without affecting mitochondrial function. Our protocol will enable the transport and storage of samples, extending and facilitating mitochondrial function analysis of liver biopsies. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Case cluster of pneumoconiosis at a coal slag processing facility.
Fagan, Kathleen M; Cropsey, Erin B; Armstrong, Jenna L
2015-05-01
During an inspection by the Occupational Safety and Health Administration (OSHA) of a small coal slag processing plant with 12 current workers, four cases of pneumoconiosis were identified among former workers. The OSHA investigation consisted of industrial hygiene sampling, a review of medical records, and case interviews. Some personal sampling measurements exceeded the OSHA Permissible Exposure Limit (PEL) for total dust exposures of 15 mg/m(3), and the measured respirable silica exposure of 0.043 mg/m(3), although below OSHA's current PEL for respirable dust containing silica, was above the American Conference of Governmental Industrial Hygienists' Threshold Limit Value (TLV). Chest x-rays for all four workers identified small opacities consistent with pneumoconiosis. This is the first known report of lung disease in workers processing coal slag and raises concerns for workers exposed to coal slag dust. © 2015 Wiley Periodicals, Inc.
Automatic liquid handling for life science: a critical review of the current state of the art.
Kong, Fanwei; Yuan, Liang; Zheng, Yuan F; Chen, Weidong
2012-06-01
Liquid handling plays a pivotal role in life science laboratories. In experiments such as gene sequencing, protein crystallization, antibody testing, and drug screening, liquid biosamples frequently must be transferred between containers of varying sizes and/or dispensed onto substrates of varying types. The sample volumes are usually small, at the micro- or nanoliter level, and the number of transferred samples can be huge when investigating large-scope combinatorial conditions. Under these conditions, liquid handling by hand is tedious, time-consuming, and impractical. Consequently, there is a strong demand for automated liquid-handling methods such as sensor-integrated robotic systems. In this article, we survey the current state of the art in automatic liquid handling, including technologies developed by both industry and research institutions. We focus on methods for dealing with small volumes at high throughput and point out challenges for future advancements.
Using digital images to measure and discriminate small particles in cotton
NASA Astrophysics Data System (ADS)
Taylor, Robert A.; Godbey, Luther C.
1991-02-01
Inages from conventional video systems are being digitized in coraputers for the analysis of small trash particles in cotton. The method has been developed to automate particle counting and area measurements for bales of cotton prepared for market. Because the video output is linearly proportional to the amount of light reflected the best spectral band for optimum particle discrimination should be centered at the wavelength of maximum difference between particles and their surroundings. However due to the spectral distribution of the illumination energy and the detector sensitivity peak image performance bands were altered. Reflectance from seven mechanically cleaned cotton lint samples and trash removed were examined for spectral contrast in the wavelength range of camera sensitivity. Pixel intensity histograms from the video systent are reported for simulated trashmeter area reference samples (painted dots on panels) and for cotton containing trash to demonstrate the particle discrimination mechanism. 2.
Zhong, Shan; Zhang, Haiping; Bai, Dongyu; Gao, Dehong; Zheng, Jie; Ding, Yi
2015-09-01
To study the prevalence of ALK, ROS1 and RET fusion genes in non-small cell lung cancer (NSCLC), and its correlation with clinicopathologic features. Formalin-fixed and paraffin-embedded tissue sections from samples of 302 patients with NSCLC were screened for ALK, ROS1, RET fusions by real-time polymerase chain reaction (PCR). All of the cases were validated by Sanger DNA sequencing. The relationship between ALK, ROS1, RET fusion genes and clinicopathologic features were analyzed. In the cohort of 302 NSCLC samples, 3.97% (12/302) were found to contain ALK fusion genes, including 3 cases with E13; A20 gene fusion, 3 cases with E6; A20 gene fusion and 3 cases with E20; A20 gene fusion. There was no statistically significant difference in patient's gender, age, smoking history and histologic type. Moreover, in the 302 NSCLC samples studied, 3.97% (12/302) were found to contain ROS1 fusion genes, with CD74-ROS1 fusion identified in 9 cases. There was no statistically significant difference in patients' gender, age, smoking history and histologic type. One non-smoking elderly female patient with pulmonary adenocarcinoma had RET gene fusion. None of the cases studied had concurrent ALK, ROS1 and RET mutations. The ALK, ROS1 and RET fusion gene mutation rates in NSCLC are low, they represent some specific molecular subtypes of NSCLC. Genetic testing has significant meaning to guide clinical targeted therapy.
A prototypic small molecule database for bronchoalveolar lavage-based metabolomics
NASA Astrophysics Data System (ADS)
Walmsley, Scott; Cruickshank-Quinn, Charmion; Quinn, Kevin; Zhang, Xing; Petrache, Irina; Bowler, Russell P.; Reisdorph, Richard; Reisdorph, Nichole
2018-04-01
The analysis of bronchoalveolar lavage fluid (BALF) using mass spectrometry-based metabolomics can provide insight into lung diseases, such as asthma. However, the important step of compound identification is hindered by the lack of a small molecule database that is specific for BALF. Here we describe prototypic, small molecule databases derived from human BALF samples (n=117). Human BALF was extracted into lipid and aqueous fractions and analyzed using liquid chromatography mass spectrometry. Following filtering to reduce contaminants and artifacts, the resulting BALF databases (BALF-DBs) contain 11,736 lipid and 658 aqueous compounds. Over 10% of these were found in 100% of samples. Testing the BALF-DBs using nested test sets produced a 99% match rate for lipids and 47% match rate for aqueous molecules. Searching an independent dataset resulted in 45% matching to the lipid BALF-DB compared to<25% when general databases are searched. The BALF-DBs are available for download from MetaboLights. Overall, the BALF-DBs can reduce false positives and improve confidence in compound identification compared to when general databases are used.
[A non-invasive portable blood-glucose monitoring system: sampling of suction effusion fluid].
Arai, T; Kayashima, S; Kikuchi, M; Kaneyoshi, A; Itoh, N
1995-04-01
We developed a new portable transcutaneous blood glucose monitoring system using non-invasive collection of suction effusion fluid (SEF) from human skin. A ion sensitive field effect transistor (ISFET) sensor was employed to measure glucose concentration in a very small quantity of the SEF. The system was composed of a couple of portions. One structure was a suction cell, and the other was a main frame. The suction cell included the ISFET glucose sensor, a dilution mechanism, and a sucking interface to human skin. The main frame contained a dilution solution reservoir, a liquid waste reservoir, a fluid pump, a vacuum pump, a micro processor, batteries, and a user interface. The system is self-contained for portable usage during up to 6 hrs monitoring. This system may be the first blood glucose monitoring equipment which does not use blood sampling.
An aerosol particle containing enriched uranium encountered in the remote upper troposphere.
Murphy, D M; Froyd, K D; Apel, E; Blake, D; Blake, N; Evangeliou, N; Hornbrook, R S; Peischl, J; Ray, E; Ryerson, T B; Thompson, C; Stohl, A
2018-04-01
We describe a submicron aerosol particle sampled at an altitude of 7 km near the Aleutian Islands that contained a small percentage of enriched uranium oxide. 235 U was 3.1 ± 0.5% of 238 U. During twenty years of aircraft sampling of millions of particles in the global atmosphere, we have rarely encountered a particle with a similarly high content of 238 U and never a particle with enriched 235 U. The bulk of the particle consisted of material consistent with combustion of heavy fuel oil. Analysis of wind trajectories and particle dispersion model results show that the particle could have originated from a variety of areas across Asia. The source of such a particle is unclear, and the particle is described here in case it indicates a novel source where enriched uranium was dispersed. Published by Elsevier Ltd.
Jeffries, Cy M.; Graewert, Melissa A.; Blanchet, Clément E.; Langley, David B.; Whitten, Andrew E.; Svergun, Dmitri I
2017-01-01
Small-angle X-ray and neutron scattering (SAXS and SANS) are techniques used to extract structural parameters and determine the overall structures and shapes of biological macromolecules, complexes and assemblies in solution. The scattering intensities measured from a sample contain contributions from all atoms within the illuminated sample volume including the solvent and buffer components as well as the macromolecules of interest. In order to obtain structural information, it is essential to prepare an exactly matched solvent blank so that background scattering contributions can be accurately subtracted from the sample scattering to obtain the net scattering from the macromolecules in the sample. In addition, sample heterogeneity caused by contaminants, aggregates, mismatched solvents, radiation damage or other factors can severely influence and complicate data analysis so it is essential that the samples are pure and monodisperse for the duration of the experiment. This Protocol outlines the basic physics of SAXS and SANS and reveals how the underlying conceptual principles of the techniques ultimately ‘translate’ into practical laboratory guidance for the production of samples of sufficiently high quality for scattering experiments. The procedure describes how to prepare and characterize protein and nucleic acid samples for both SAXS and SANS using gel electrophoresis, size exclusion chromatography and light scattering. Also included are procedures specific to X-rays (in-line size exclusion chromatography SAXS) and neutrons, specifically preparing samples for contrast matching/variation experiments and deuterium labeling of proteins. PMID:27711050
Virshup, Aaron M.; Contreras-García, Julia; Wipf, Peter; Yang, Weitao; Beratan, David N.
2013-01-01
The “small molecule universe” (SMU), the set of all synthetically feasible organic molecules of 500 Daltons molecular weight or less, is estimated to contain over 1060 structures, making exhaustive searches for structures of interest impractical. Here, we describe the construction of a “representative universal library” spanning the SMU that samples the full extent of feasible small molecule chemistries. This library was generated using the newly developed Algorithm for Chemical Space Exploration with Stochastic Search (ACSESS). ACSESS makes two important contributions to chemical space exploration: it allows the systematic search of the unexplored regions of the small molecule universe, and it facilitates the mining of chemical libraries that do not yet exist, providing a near-infinite source of diverse novel compounds. PMID:23548177
Attenuation of the Acoustic Signal Propagating Through a Bubbly Liquid Layer
NASA Astrophysics Data System (ADS)
Gubaidullin, D. A.; Nikiforov, A. A.
2018-01-01
The acoustic signal dynamics in a five-layer medium containing two liquid layers with polydisperse gas bubbles has been investigated. Calculations have been made for the interaction between the pulse perturbation of smallamplitude pressure and a multilayer sample containing two layers of industrial gel with polydisperse air bubbles. It has been shown that a small content of bubbles (about 0.1 vol. %) in a thin gel layer decreases tenfold or more the amplitude of acoustic waves with frequencies close to the resonance frequency of natural oscillations of bubbles. There are frequency ranges thereby where the influence of the bubbly layer is insignificant.
Is the Lamb shift chemically significant?
NASA Technical Reports Server (NTRS)
Dyall, Kenneth G.; Bauschlicher, Charles W., Jr.; Schwenke, David W.; Pyykko, Pekka; Arnold, James (Technical Monitor)
2001-01-01
The contribution of the Lamb shift to the atomization energies of some prototype molecules, BF3, AlF3, and GaF3, is estimated by a perturbation procedure. It is found to be in the range of 3-5% of the one-electron scalar relativistic contribution to the atomization energy. The maximum absolute value is 0.2 kcal/mol for GaF3. These sample calculations indicate that the Lamb shift is probably small enough to be neglected for energetics of molecules containing light atoms if the target accuracy is 1 kcal/mol, but for higher accuracy calculations and for molecules containing heavy elements it must be considered.
Martin F. Jurgensen; Deborah S. Page-Dumroese; Robert E. Brown; Joanne M. Tirocke; Chris A. Miller; James B. Pickens; Min Wang
2017-01-01
Soils with high rock content are common in many US forests, and contain large amounts of stored C. Accurate measurements of soil bulk density and rock content are critical for calculating and assessing changes in both C and nutrient pool size, but bulk density sampling methods have limitations and sources of variability. Therefore, we evaluated the use of small-...
Focussed Ion Beam Milling and Scanning Electron Microscopy of Brain Tissue
Knott, Graham; Rosset, Stéphanie; Cantoni, Marco
2011-01-01
This protocol describes how biological samples, like brain tissue, can be imaged in three dimensions using the focussed ion beam/scanning electron microscope (FIB/SEM). The samples are fixed with aldehydes, heavy metal stained using osmium tetroxide and uranyl acetate. They are then dehydrated with alcohol and infiltrated with resin, which is then hardened. Using a light microscope and ultramicrotome with glass knives, a small block containing the region interest close to the surface is made. The block is then placed inside the FIB/SEM, and the ion beam used to roughly mill a vertical face along one side of the block, close to this region. Using backscattered electrons to image the underlying structures, a smaller face is then milled with a finer ion beam and the surface scrutinised more closely to determine the exact area of the face to be imaged and milled. The parameters of the microscope are then set so that the face is repeatedly milled and imaged so that serial images are collected through a volume of the block. The image stack will typically contain isotropic voxels with dimenions as small a 4 nm in each direction. This image quality in any imaging plane enables the user to analyse cell ultrastructure at any viewing angle within the image stack. PMID:21775953
The Antaeus Project - An orbital quarantine facility for analysis of planetary return samples
NASA Technical Reports Server (NTRS)
Sweet, H. C.; Bagby, J. R.; Devincenzi, D. L.
1983-01-01
A design is presented for an earth-orbiting facility for the analysis of planetary return samples under conditions of maximum protection against contamination but minimal damage to the sample. The design is keyed to a Mars sample return mission profile, returning 1 kg of documented subsamples, to be analyzed in low earth orbit by a small crew aided by automated procedures, tissue culture and microassay. The facility itself would consist of Spacelab shells, formed into five modules of different sizes with purposes of power supply, habitation, supplies and waste storage, the linking of the facility, and both quarantine and investigation of the samples. Three barriers are envisioned to protect the biosphere from any putative extraterrestrial organisms: sealed biological containment cabinets within the Laboratory Module, the Laboratory Module itself, and the conditions of space surrounding the facility.
Bove, D.J.; Walton-Day, K.; Kimball, B.A.
2009-01-01
Investigations within the Silverton caldera, in southwestern Colorado, used a combination of traditional geological mapping, alteration-assemblage mapping, and aqueous geochemical sampling that showed a relationship between geological and hydrologic features that may be used to better understand the provenance and evolution of the water. Veins containing fluorite, huebnerite, and elevated molybdenum concentrations are temporally and perhaps genetically associated with the emplacement of high-silica rhyolite intrusions. Both the rhyolites and the fluorite-bearing veins produce waters containing elevated concentrations of F-, K and Be. The identification of water samples with elevated F/Cl molar ratios (> 10) has also aided in the location of water draining F-rich sources, even after these waters have been diluted substantially. These unique aqueous geochemical signatures can be used to relate water chemistry to key geological features and mineralized source areas. Two examples that illustrate this relationship are: (1) surface-water samples containing elevated F-concentrations (> 1.8 mg/l) that closely bracket the extent of several small high-silica rhyolite intrusions; and (2) water samples containing elevated concentrations of F-(> 1.8 mg/ l) that spatially relate to mines or areas that contain late-stage fluorite/huebnerite veins. In two additional cases, the existence of high F-concentrations in water can be used to: (1) infer interaction of the water with mine waste derived from systems known to contain the fluorite/huebnerite association; and (2) relate changes in water quality over time at a high elevation mine tunnel to plugging of a lower elevation mine tunnel and the subsequent rise of the water table into mineralized areas containing fluorite/huebnerite veining. Thus, the unique geochemical signature of the water produced from fluorite veins indicates the location of high-silica rhyolites, mines, and mine waste containing the veins. Existence of high F-concentrations along with K and Be in water in combination with other geological evidence may be used to better understand the provenance of the water. ?? 2009 AAG/Geological Society of London.
Comparison of Grab, Air, and Surface Results for Radiation Site Characterization
NASA Astrophysics Data System (ADS)
Glassford, Eric Keith
2011-12-01
The use of proper sampling methods and sample types for evaluating sites believed to be contaminated with radioactive materials is necessary to avoid misrepresenting conditions at the site. This study was designed to investigate if the site characterization, based upon uranium contamination measured in different types of samples, is dependent upon the mass of the sample collected. A bulk sample of potentially contaminated interior dirt was collected from an abandoned metal processing mill that rolled uranium between 1948 and 1956. The original mill dates from 1910 and has a dirt floor. The bulk sample was a mixture of dirt, black and yellow particles of metal dust, and small fragments of natural debris. Small mass (approximately 0.75 grams (g)) and large mass (approximately 70g) grab samples were prepared from the bulk sample material to simulate collection of a "grab" type sample. Air sampling was performed by re-suspending a portion of the bulk sample material using a vibration table to simulate airborne contamination that might be present during site remediation. Additionally, samples of removable contaminated surface dust were collected on 47 mm diameter filter paper by wiping the surfaces of the exposure chamber used to resuspend the bulk material. Certified reference materials, one containing a precisely known quantity of U 3O8 and one containing a known quantity of natural uranium, were utilized to calibrate the gamma spectrometry measurement system. Non-destructive gamma spectrometry measurements were used to determine the content of uranium-235 (235U) at 185 keV and 143 keV, thorium-234 (234Th) at 63 keV, and protactinium-234m (234mPa) at 1001 keV in each sample. Measurement of natural uranium in small, 1 g samples is usually accomplished by radiochemical analysis in order to measure alpha particles emitted by 238U, 235U, and 234U. However, uranium in larger bulk samples can also be measured non-destructively using gamma spectrometry to detect the low energy photons from 234Th and 234mPa, the short-lived decay products of 238U, and 235U. Two sided t-tests and coefficient of variation were used to compare sampling types. The large grab samples had the lowest calculated coefficient of variation results for activity and atom percentage. The wipe samples had the highest calculated coefficient of variation of mean specific activity (dis/sec/g) for all three energies. The air filter samples had the highest coefficient of variation calculation for mean atom percentage, for both uranium isotopes examined. The data indicated that the large mass sample was the most effective at characterizing the rolling mill radioactive site conditions, since this would indicate which samples had the smallest variations compared to the mean. Additionally, measurement results of natural uranium in the samples indicate that the distribution of radioactive contamination at the sampling location is most likely non-homogeneous and that the size of the sample collected and analyzed must be sufficiently large to insure that the analytical results are truly representative of the activity present.
Development of methods to measure virus inactivation in fresh waters.
Ward, R L; Winston, P E
1985-01-01
This study concerns the identification and correction of deficiencies in methods used to measure inactivation rates of enteric viruses seeded into environmental waters. It was found that viable microorganisms in an environmental water sample increased greatly after addition of small amounts of nutrients normally present in the unpurified seed virus preparation. This burst of microbial growth was not observed after seeding the water with purified virus. The use of radioactively labeled poliovirus revealed that high percentages of virus particles, sometimes greater than 99%, were lost through adherence to containers, especially in less turbid waters. This effect was partially overcome by the use of polypropylene containers and by the absence of movement during incubation. Adherence to containers clearly demonstrated the need for labeled viruses to monitor losses in this type of study. Loss of viral infectivity in samples found to occur during freezing was avoided by addition of broth. Finally, microbial contamination of the cell cultures during infectivity assays was overcome by the use of gentamicin and increased concentrations of penicillin, streptomycin, and amphotericin B. PMID:3004328
Formation of apatitic calcium phosphates in a Na-K-phosphate solution of pH 7.4.
Tas, A C; Aldinger, F
2005-02-01
Poorly crystalline, apatitic calcium phosphate powders have been synthesized by slowly adding a Na- and K-containing reference phosphate solution with a pH value of 7.4 to an aqueous calcium nitrate solution at 37 degrees C. Nano-particulated apatitic powders obtained were shown to contain small amounts of Na and K, which render them more similar in chemical composition to that of the bone mineral. Precipitated and dried powders were found to exhibit self-hardening cement properties when kneaded in a mortar with a sodium citrate- and sodium phosphate-containing starter solution. The same phosphate solution used in powder synthesis was found to be able to partially convert natural, white and translucent marble pieces of calcite (CaCO3) into calcium-deficient hydroxyapatite upon aging the samples in that solution for 3 days at 60 degrees C. Sample characterization was performed by using scanning electron microscopy, X-ray diffraction, Fourier-transform infrared spectroscopy, inductively-coupled plasma atomic emission spectroscopy, and simultaneous thermogravimetry and differential thermal analysis.
Toxicity reduction of photo processing wastewaters
Wang, W.
1992-01-01
The photo processing industry can be characterized by treatment processes and subsequent silver recovery. The effluents generated all contain various amounts of silver. The objectives of this study were to determine toxicity of photo processing effluents and to explore their toxicity mitigation. Six samples, from small shops to a major photo processing center, were studied. Two samples (I and VI) were found to be extremely toxic, causing 100 and 99% inhibition of duckweed frond reproduction, respectively, and were used for subsequent toxicity reduction experiments. Lime and sodium sulfide were effective for the toxicity reduction of Sample VI; both reduced its toxicity to negligible. Sample I was far more toxic and was first diluted to 2.2% and then treated with 0.5 g lime/100 mL, reducing toxicity from 100% to 12% inhibition.
Khan, Rishi L; Gonye, Gregory E; Gao, Guang; Schwaber, James S
2006-01-01
Background Using microarrays by co-hybridizing two samples labeled with different dyes enables differential gene expression measurements and comparisons across slides while controlling for within-slide variability. Typically one dye produces weaker signal intensities than the other often causing signals to be undetectable. In addition, undetectable spots represent a large problem for two-color microarray designs and most arrays contain at least 40% undetectable spots even when labeled with reference samples such as Stratagene's Universal Reference RNAs™. Results We introduce a novel universal reference sample that produces strong signal for all spots on the array, increasing the average fraction of detectable spots to 97%. Maximizing detectable spots on the reference image channel also decreases the variability of microarray data allowing for reliable detection of smaller differential gene expression changes. The reference sample is derived from sequence contained in the parental EST clone vector pT7T3D-Pac and is called vector RNA (vRNA). We show that vRNA can also be used for quality control of microarray printing and PCR product quality, detection of hybridization anomalies, and simplification of spot finding and segmentation tasks. This reference sample can be made inexpensively in large quantities as a renewable resource that is consistent across experiments. Conclusion Results of this study show that vRNA provides a useful universal reference that yields high signal for almost all spots on a microarray, reduces variation and allows for comparisons between experiments and laboratories. Further, it can be used for quality control of microarray printing and PCR product quality, detection of hybridization anomalies, and simplification of spot finding and segmentation tasks. This type of reference allows for detection of small changes in differential expression while reference designs in general allow for large-scale multivariate experimental designs. vRNA in combination with reference designs enable systems biology microarray experiments of small physiologically relevant changes. PMID:16677381
Raue, Katharina; Heuer, Lea; Böhm, Claudia; Wolken, Sonja; Epe, Christian; Strube, Christina
2017-12-01
The results of coproscopical examinations in domestic animals and hedgehogs carried out as routine diagnostics in the years 2003 to 2012 at the Institute for Parasitology, University of Veterinary Medicine Hannover, Germany, are presented. Of 3475 horse faecal samples, 30.1% contained stages of strongyles and 1.3% eggs of Strongyloides westeri and Parascaris equorum, respectively. The most frequently observed parasite stages in 1416 cattle faecal samples were Eimeria oocysts (21.3%) and strongyle eggs or larvae (15.9%). Dictyocaulus viviparus larvae and Fasciola hepatica eggs were identified in 0.9 and 1.3% of samples. Of 574 bovine faecal samples analysed by carbol-fuchsin staining, 39.9% were positive for Cryptosporidium oocysts. Stages of strongyles were found in 52.4% of sheep (n = 374) and 44.9% of goat faeces (n = 98) and Eimeria oocysts in 41.4 and 32.7% of their faeces, respectively. Of 1848 pig faecal samples, 3.0% contained stages of strongyles, 1.6% eggs of Ascaris suum and 3.3% coccidian (Eimeria or Cystoisospora spp.) oocysts. The most frequently detected helminth eggs in faecal samples of dogs (n = 2731) and cats (n = 903) were Toxocara spp. (2.8 and 3.9%, respectively). Cystoisospora oocysts were identified in 5.6% of dog and 2.4% of cat faeces. Furthermore, 0.7% of the cat samples were positive for small Toxoplasma gondii-like oocysts. The faecal samples of rabbits (n = 434) contained eggs of Passalurus ambiguus (3.0%), strongyles (1.8%) and Trichuris leporis (0.2%) as well as Eimeria oocysts (21.2%). The most abundant nematodes in the samples of hedgehogs (n = 205) were Capillaria spp. (39.5%) and Crenosoma striatum (26.8%); coccidian oocysts were found in 14.2% of the samples.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Exemption of small low pressure gas cylinders... STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1106-6 Exemption of small low pressure gas cylinders containing nonflammable or nonexplosive gas mixtures. Small low pressure gas cylinders containing...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Exemption of small low pressure gas cylinders... STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1106-6 Exemption of small low pressure gas cylinders containing nonflammable or nonexplosive gas mixtures. Small low pressure gas cylinders containing...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Exemption of small low pressure gas cylinders... STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1106-6 Exemption of small low pressure gas cylinders containing nonflammable or nonexplosive gas mixtures. Small low pressure gas cylinders containing...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Exemption of small low pressure gas cylinders... STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1106-6 Exemption of small low pressure gas cylinders containing nonflammable or nonexplosive gas mixtures. Small low pressure gas cylinders containing...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Exemption of small low pressure gas cylinders... STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1106-6 Exemption of small low pressure gas cylinders containing nonflammable or nonexplosive gas mixtures. Small low pressure gas cylinders containing...
Ultrasonic characterization of single drops of liquids
Sinha, Dipen N.
1998-01-01
Ultrasonic characterization of single drops of liquids. The present invention includes the use of two closely spaced transducers, or one transducer and a closely spaced reflector plate, to form an interferometer suitable for ultrasonic characterization of droplet-size and smaller samples without the need for a container. The droplet is held between the interferometer elements, whose distance apart may be adjusted, by surface tension. The surfaces of the interferometer elements may be readily cleansed by a stream of solvent followed by purified air when it is desired to change samples. A single drop of liquid is sufficient for high-quality measurement. Examples of samples which may be investigated using the apparatus and method of the present invention include biological specimens (tear drops; blood and other body fluid samples; samples from tumors, tissues, and organs; secretions from tissues and organs; snake and bee venom, etc.) for diagnostic evaluation, samples in forensic investigations, and detection of drugs in small quantities.
Novel methodology to isolate microplastics from vegetal-rich samples.
Herrera, Alicia; Garrido-Amador, Paloma; Martínez, Ico; Samper, María Dolores; López-Martínez, Juan; Gómez, May; Packard, Theodore T
2018-04-01
Microplastics are small plastic particles, globally distributed throughout the oceans. To properly study them, all the methodologies for their sampling, extraction, and measurement should be standardized. For heterogeneous samples containing sediments, animal tissues and zooplankton, several procedures have been described. However, definitive methodologies for samples, rich in algae and plant material, have not yet been developed. The aim of this study was to find the best extraction protocol for vegetal-rich samples by comparing the efficacies of five previously described digestion methods, and a novel density separation method. A protocol using 96% ethanol for density separation was better than the five digestion methods tested, even better than using H 2 O 2 digestion. As it was the most efficient, simple, safe and inexpensive method for isolating microplastics from vegetal rich samples, we recommend it as a standard separation method. Copyright © 2018 Elsevier Ltd. All rights reserved.
Materials samples face rigors of space.
Flinn, Edward D
2002-07-01
The Materials International Space Station Experiment (MISSE) is described. This project is designed to conduct long duration materials tests on samples attached to the ISS. A batch of 750 material samples were delivered on STS-105 and attached to the ISS airlock. They will be exposed to the space environment for 18 months and are slated to return on STS-114. A second batch of 750 samples is being prepared. The experiment containers were used originally for the Mir Environmental Effects Payload, which tested a variety of substances, including some slated for use on the ISS. Researchers are particularly interested in the effects of atomic oxygen on the samples. Some samples are being tested to determine their use in radiation protection. As part of the MISSE project, ultrathin tether materials are being tested for use on the Propulsive Small Expendable Depoloyer System (ProSEDS), which will use a tether system to change a satellite's orbital altitude.
Liou, Saou-Hsing; Yang, Gordon C C; Wang, Chih-Lung; Chiu, Yu-Han
2014-07-30
This 5-month study contains two parts: (1) to monitor the concentrations of 11 phthalate esters metabolites (PAEMs) and two beta-agonists in human urine samples collected from a small group of consented participants including 16 females and five males; and (2) to analyze the residues of phthalate esters (PAEs) and beta-agonists in various categories of drinking water consumed by the same group of subjects. Each category of human urine and drinking water had 183 samples of its own. The analytical results showed that nine PAEMs were detected in human urine and eight PAEs were detected in drinking water samples. It was found that average concentrations of PAEMs increased as the age increased, but no significant difference between sexes. Further, using the principal component analysis, the loadings of age effect were found to be two times greater than that of gender effect in terms of four DEHP metabolites. Regarding beta-agonists of concern (i.e., ractopamine and salbutamol), they were neither detected in human urine nor drinking water samples in this study. Copyright © 2014 Elsevier B.V. All rights reserved.
Novel immunoassay formats for integrated microfluidic circuits: diffusion immunoassays (DIA)
NASA Astrophysics Data System (ADS)
Weigl, Bernhard H.; Hatch, Anson; Kamholz, Andrew E.; Yager, Paul
2000-03-01
Novel designs of integrated fluidic microchips allow separations, chemical reactions, and calibration-free analytical measurements to be performed directly in very small quantities of complex samples such as whole blood and contaminated environmental samples. This technology lends itself to applications such as clinical diagnostics, including tumor marker screening, and environmental sensing in remote locations. Lab-on-a-Chip based systems offer many *advantages over traditional analytical devices: They consume extremely low volumes of both samples and reagents. Each chip is inexpensive and small. The sampling-to-result time is extremely short. They perform all analytical functions, including sampling, sample pretreatment, separation, dilution, and mixing steps, chemical reactions, and detection in an integrated microfluidic circuit. Lab-on-a-Chip systems enable the design of small, portable, rugged, low-cost, easy to use, yet extremely versatile and capable diagnostic instruments. In addition, fluids flowing in microchannels exhibit unique characteristics ('microfluidics'), which allow the design of analytical devices and assay formats that would not function on a macroscale. Existing Lab-on-a-chip technologies work very well for highly predictable and homogeneous samples common in genetic testing and drug discovery processes. One of the biggest challenges for current Labs-on-a-chip, however, is to perform analysis in the presence of the complexity and heterogeneity of actual samples such as whole blood or contaminated environmental samples. Micronics has developed a variety of Lab-on-a-Chip assays that can overcome those shortcomings. We will now present various types of novel Lab- on-a-Chip-based immunoassays, including the so-called Diffusion Immunoassays (DIA) that are based on the competitive laminar diffusion of analyte molecules and tracer molecules into a region of the chip containing antibodies that target the analyte molecules. Advantages of this technique are a reduction in reagents, higher sensitivity, minimal preparation of complex samples such as blood, real-time calibration, and extremely rapid analysis.
Self-contained microfluidic systems: a review.
Boyd-Moss, Mitchell; Baratchi, Sara; Di Venere, Martina; Khoshmanesh, Khashayar
2016-08-16
Microfluidic systems enable rapid diagnosis, screening and monitoring of diseases and health conditions using small amounts of biological samples and reagents. Despite these remarkable features, conventional microfluidic systems rely on bulky expensive external equipment, which hinders their utility as powerful analysis tools outside of research laboratories. 'Self-contained' microfluidic systems, which contain all necessary components to facilitate a complete assay, have been developed to address this limitation. In this review, we provide an in-depth overview of self-contained microfluidic systems. We categorise these systems based on their operating mechanisms into three major groups: passive, hand-powered and active. Several examples are provided to discuss the structure, capabilities and shortcomings of each group. In particular, we discuss the self-contained microfluidic systems enabled by active mechanisms, due to their unique capability for running multi-step and highly controllable diagnostic assays. Integration of self-contained microfluidic systems with the image acquisition and processing capabilities of smartphones, especially those equipped with accessory optical components, enables highly sensitive and quantitative assays, which are discussed. Finally, the future trends and possible solutions to expand the versatility of self-contained, stand-alone microfluidic platforms are outlined.
Over-the-Counter "Adrenal Support" Supplements Contain Thyroid and Steroid-Based Adrenal Hormones.
Akturk, Halis Kaan; Chindris, Ana Maria; Hines, Jolaine M; Singh, Ravinder J; Bernet, Victor J
2018-03-01
To assess whether dietary supplements that are herbal and/or animal-derived products, marketed for enhancing metabolism or promoting energy, "adrenal fatigue," or "adrenal support," contain thyroid or steroid hormones. Twelve dietary adrenal support supplements were purchased. Pregnenolone, androstenedione, 17-hydroxyprogesterone, cortisol, cortisone, dehydroepiandrosterone sulfate, synthetic glucocorticoids (betamethasone, dexamethasone, fludrocortisone, megestrol acetate, methylprednisolone, prednisolone, prednisone, budesonide, and triamcinolone acetonide) levels were measured twice in samples in a blinded fashion. This study was conducted between February 1, 2016, and November 1, 2016. Among steroids, pregnenolone was the most common hormone in the samples. Budesonide, 17-hydroxyprogesterone, androstenedione, cortisol, and cortisone were the others in order of prevalence. All the supplements revealed a detectable amount of triiodothyronine (T3) (63-394.9 ng/tablet), 42% contained pregnenolone (66.12-205.2 ng/tablet), 25% contained budesonide (119.5-610 ng/tablet), 17% contained androstenedione (1.27-7.25 ng/tablet), 8% contained 17-OH progesterone (30.09 ng/tablet), 8% contained cortisone (79.66 ng/tablet), and 8% contained cortisol (138.5 ng/tablet). Per label recommended doses daily exposure was up to 1322 ng for T3, 1231.2 ng for pregnenolone, 1276.4 ng for budesonide, 29 ng for androstenedione, 60.18 ng for 17-OH progesterone, 277 ng for cortisol, and 159.32 ng for cortisone. All the supplements studied contained a small amount of thyroid hormone and most contained at least 1 steroid hormone. This is the first study that measured thyroid and steroid hormones in over-the-counter dietary "adrenal support" supplements in the United States. These results may highlight potential risks of hidden ingredients in unregulated supplements. Copyright © 2017 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Delwart, Eric; Li, Linlin
2012-03-01
The genomes of numerous circoviruses and distantly related circular ssDNA viruses encoding a rolling circle replication initiator protein (Rep) have been characterized from the tissues of mammals, fish, insects, plants (geminivirus and nanovirus), in human and animal feces, in an algae cell, and in diverse environmental samples. We review the genome organization, phylogenetic relationships and initial prevalence studies of cycloviruses, a proposed new genus in the Circoviridae family. Viral fossil rep sequences were also recently identified integrated on the chromosomes of mammals, frogs, lancelets, crustaceans, mites, gastropods, roundworms, placozoans, hydrozoans, protozoans, land plants, fungi, algae, and phytoplasma bacterias and their plasmids, reflecting the very wide past host range of rep bearing viruses. An ancient origin for viruses with Rep-encoding small circular ssDNA genomes, predating the diversification of eukaryotes, is discussed. The cellular hosts and pathogenicity of many recently described rep-containing circular ssDNA genomes remain to be determined. Future studies of the virome of single cell and multi-cellular eukaryotes are likely to further extend the known diversity and host-range of small rep-containing circular ssDNA viral genomes. Copyright © 2011 Elsevier B.V. All rights reserved.
Meintjies, E; Strelow, F W; Victor, A H
1987-04-01
Traces and small amounts of bismuth can be separated from gram amounts of thallium and silver by successively eluting these elements with 0.3M and 0.6M nitric acid from a column containing 13 ml (3 g) of AG50W-X4, a cation-exchanger (100-200 mesh particle size) with low cross-linking. Bismuth is retained and can be eluted with 0.2M hydrobromic acid containing 20% v/v acetone, leaving many other trace elements absorbed. Elution of thallium is quite sharp, but silver shows a small amount of tailing (less than 1 gmg/ml silver in the eluate) when gram amounts are present, between 20 and 80 mug of silver appearing in the bismuth fraction. Relevant elution curves and results for the analysis of synthetic mixtures containing between 50 mug and 10 mg of bismuth and up to more than 1 g of thallium and silver are presented, as well as results for bismuth in a sample of thallium metal and in Merck thallium(I) carbonate. As little as 0.01 ppm of bismuth can be determined when the separation is combined with electrothermal atomic-absorption spectrometry.
NASA Astrophysics Data System (ADS)
Walsh, Patrick S.; Blodgett, Karl N.; McBurney, Carl; Gellman, Samuel H.; Zwier, Timothy S.
Glutamine is vitally important to a class of neurodegenerative diseases called poly-glutamine (poly-Q) repeat diseases such as Huntington's Disease (HD). Recent studies have revealed a pathogenic pathway that proceeds through misfolding of poly-Q regions into characteristic β-turn/ β-hairpin structures that are highly correlated with toxicity. The inherent conformational preferences of small glutamine containing peptides (Ac-Q-Q-NHBn and Ac-A-Q-NHBn) were studied using conformation-specific IR and UV spectroscopies, with the goal of probing the delicate interplay between three competitive hydrogen bonding motifs: backbone-backbone, sidechain-backbone, and sidechain-sidechain hydrogen bonds. Laser desorption, coupled with a supersonic expansion, was used to introduce the non-thermally labile sample into the gas-phase. Resonant ion-dip infrared (RIDIR) spectroscopy is a powerful tool for recording the vibrational spectra of single conformational isomers and was used here to reveal the innate structural preferences of the glutamine containing peptides. Experimental results are compared against density functional calculations to arrive at firm conformational assignments. Our results demonstrate a striking preference for β-turn formation in the non-polar environment of the gas-phase. Previous Affiliation: Purdue University, Department of Chemistry.
NASA Astrophysics Data System (ADS)
Xie, Xing; Bahnemann, Janina; Wang, Siwen; Yang, Yang; Hoffmann, Michael R.
2016-02-01
Detection and quantification of pathogens in water is critical for the protection of human health and for drinking water safety and security. When the pathogen concentrations are low, large sample volumes (several liters) are needed to achieve reliable quantitative results. However, most microbial identification methods utilize relatively small sample volumes. As a consequence, a concentration step is often required to detect pathogens in natural waters. Herein, we introduce a novel water sample concentration method based on superabsorbent polymer (SAP) beads. When SAP beads swell with water, small molecules can be sorbed within the beads, but larger particles are excluded and, thus, concentrated in the residual non-sorbed water. To illustrate this approach, millimeter-sized poly(acrylamide-co-itaconic acid) (P(AM-co-IA)) beads are synthesized and successfully applied to concentrate water samples containing two model microorganisms: Escherichia coli and bacteriophage MS2. Experimental results indicate that the size of the water channel within water swollen P(AM-co-IA) hydrogel beads is on the order of several nanometers. The millimeter size coupled with a negative surface charge of the beads are shown to be critical in order to achieve high levels of concentration. This new concentration procedure is very fast, effective, scalable, and low-cost with no need for complex instrumentation.
Xie, Xing; Bahnemann, Janina; Wang, Siwen; Yang, Yang; Hoffmann, Michael R
2016-02-15
Detection and quantification of pathogens in water is critical for the protection of human health and for drinking water safety and security. When the pathogen concentrations are low, large sample volumes (several liters) are needed to achieve reliable quantitative results. However, most microbial identification methods utilize relatively small sample volumes. As a consequence, a concentration step is often required to detect pathogens in natural waters. Herein, we introduce a novel water sample concentration method based on superabsorbent polymer (SAP) beads. When SAP beads swell with water, small molecules can be sorbed within the beads, but larger particles are excluded and, thus, concentrated in the residual non-sorbed water. To illustrate this approach, millimeter-sized poly(acrylamide-co-itaconic acid) (P(AM-co-IA)) beads are synthesized and successfully applied to concentrate water samples containing two model microorganisms: Escherichia coli and bacteriophage MS2. Experimental results indicate that the size of the water channel within water swollen P(AM-co-IA) hydrogel beads is on the order of several nanometers. The millimeter size coupled with a negative surface charge of the beads are shown to be critical in order to achieve high levels of concentration. This new concentration procedure is very fast, effective, scalable, and low-cost with no need for complex instrumentation.
Rainville, Paul D; Simeone, Jennifer L; Root, Dan S; Mallet, Claude R; Wilson, Ian D; Plumb, Robert S
2015-03-21
The emergence of micro sampling techniques holds great potential to improve pharmacokinetic data quality, reduce animal usage, and save costs in safety assessment studies. The analysis of these samples presents new challenges for bioanalytical scientists, both in terms of sample processing and analytical sensitivity. The use of two dimensional LC/MS with, at-column-dilution for the direct analysis of highly organic extracts prepared from biological fluids such as dried blood spots and plasma is demonstrated. This technique negated the need to dry down and reconstitute, or dilute samples with water/aqueous buffer solutions, prior to injection onto a reversed-phase LC system. A mixture of model drugs, including bromhexine, triprolidine, enrofloxacin, and procaine were used to test the feasibility of the method. Finally an LC/MS assay for the probe pharmaceutical rosuvastatin was developed from dried blood spots and protein-precipitated plasma. The assays showed acceptable recovery, accuracy and precision according to US FDA guidelines. The resulting analytical method showed an increase in assay sensitivity of up to forty fold as compared to conventional methods by maximizing the amount loaded onto the system and the MS response for the probe pharmaceutical rosuvastatin from small volume samples.
Xie, Xing; Bahnemann, Janina; Wang, Siwen; Yang, Yang; Hoffmann, Michael R.
2016-01-01
Detection and quantification of pathogens in water is critical for the protection of human health and for drinking water safety and security. When the pathogen concentrations are low, large sample volumes (several liters) are needed to achieve reliable quantitative results. However, most microbial identification methods utilize relatively small sample volumes. As a consequence, a concentration step is often required to detect pathogens in natural waters. Herein, we introduce a novel water sample concentration method based on superabsorbent polymer (SAP) beads. When SAP beads swell with water, small molecules can be sorbed within the beads, but larger particles are excluded and, thus, concentrated in the residual non-sorbed water. To illustrate this approach, millimeter-sized poly(acrylamide-co-itaconic acid) (P(AM-co-IA)) beads are synthesized and successfully applied to concentrate water samples containing two model microorganisms: Escherichia coli and bacteriophage MS2. Experimental results indicate that the size of the water channel within water swollen P(AM-co-IA) hydrogel beads is on the order of several nanometers. The millimeter size coupled with a negative surface charge of the beads are shown to be critical in order to achieve high levels of concentration. This new concentration procedure is very fast, effective, scalable, and low-cost with no need for complex instrumentation. PMID:26876979
Character of the opposition effect and negative polarization
NASA Technical Reports Server (NTRS)
Pieters, Carle M.; Shkuratov, Yu. G.; Stankevich, D. G.
1991-01-01
Photometric and polarimetric properties at small phase angles were measured for silicates with controlled surface properties in order to distinguish properties that are associated with surface reflection from those that are associated with multiple scattering from internal grain boundaries. These data provide insight into the causes and conditions of photometric properties observed at small phase angles for dark bodies of the solar system. Obsidian was chosen to represent a silicate dielectric with no internal scattering boundaries. Because obsidian is free of internal scatterers, light reflected from both the rough and smooth obsidian samples is almost entirely single and multiple Fresnel reflections form surface facets with no body component. Surface structure alone cannot produce an opposition effect. Comparison of the obsidian and basalt results indicates that for an opposition effect to occur, surface texture must be both rough and contain internal scattering interfaces. Although the negative polarization observed for the obsidian samples indicates single and multiple reflections are part of negative polarization, the longer inversion angle of the multigrain inversion samples implies that internal reflections must also contribute a significant negative polarization component.
Manufacturing and characterization of Ni-free N-containing ODS austenitic alloy
NASA Astrophysics Data System (ADS)
Mori, A.; Mamiya, H.; Ohnuma, M.; Ilavsky, J.; Ohishi, K.; Woźniak, Jarosław; Olszyna, A.; Watanabe, N.; Suzuki, J.; Kitazawa, H.; Lewandowska, M.
2018-04-01
Ni-free N-containing oxide dispersion strengthened (ODS) austenitic alloys were manufactured by mechanical alloying (MA) followed by spark plasma sintering (SPS). The phase evolutions during milling under a nitrogen atmosphere and after sintering were studied by X-ray diffraction (XRD). Transmission electron microcopy (TEM) and alloy contrast variation analysis (ACV), including small-angle neutron scattering (SANS) and ultra-small-angle X-ray scattering (USAXS), revealed the existence of nanoparticles with a diameter of 3-51 nm for the samples sintered at 950 °C. Sintering at 1000 °C for 5 and 15 min caused slight growth and a significant coarsening of the nanoparticles, up to 70 nm and 128 nm, respectively. The ACV analysis indicated the existence of two populations of Y2O3, ε-martensite and MnO. The dispersive X-ray spectrometry (EDS) confirmed two kinds of nanoparticles, Y2O3 and MnO. The material was characterized by superior micro-hardness, of above 500 HV0.1.
Manufacturing and characterization of Ni-free N-containing ODS austenitic alloys
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kowalska-Mori, A.; Mamiya, H.; Ohnuma, M.
Ni-free N-containing oxide dispersion strengthened (ODS) austenitic alloys were manufactured by mechanical alloying (MA) followed by spark plasma sintering (SPS). The phase evolutions during milling under a nitrogen atmosphere and after sintering were studied by X-ray diffraction (XRD). Transmission electron microcopy (TEM) and contrast variation analysis (ACV), including small-angle neutron scattering (SANS) and ultra-small X-ray scattering (USAXS), revealed the existence of nanoparticles with a diameter of 3-51 nm for the samples sintered at 950 ºC. Sintering at 1000 ºC for 5 and 15 min caused slight growth and a significant coarsening of the nanoparticles, up to 70 nm and 128more » nm, respectively. The ACV analysis indicated the existence of two populations of Y2O3, ε-martensite and MnO. The dispersive X-ray spectrometry (EDS) confirmed two kinds of nanoparticles, Y2O3 and MnO. The material was characterized by superior micro-hardness, of above 500 HV0.1.« less
Manufacturing and characterization of Ni-free N-containing ODS austenitic alloys
Kowalska-Mori, A.; Mamiya, H.; Ohnuma, M.; ...
2018-01-17
Ni-free N-containing oxide dispersion strengthened (ODS) austenitic alloys were manufactured by mechanical alloying (MA) followed by spark plasma sintering (SPS). The phase evolutions during milling under a nitrogen atmosphere and after sintering were studied by X-ray diffraction (XRD). Transmission electron microcopy (TEM) and contrast variation analysis (ACV), including small-angle neutron scattering (SANS) and ultra-small X-ray scattering (USAXS), revealed the existence of nanoparticles with a diameter of 3-51 nm for the samples sintered at 950 ºC. Sintering at 1000 ºC for 5 and 15 min caused slight growth and a significant coarsening of the nanoparticles, up to 70 nm and 128more » nm, respectively. The ACV analysis indicated the existence of two populations of Y2O3, ε-martensite and MnO. The dispersive X-ray spectrometry (EDS) confirmed two kinds of nanoparticles, Y2O3 and MnO. The material was characterized by superior micro-hardness, of above 500 HV0.1.« less
NASA Technical Reports Server (NTRS)
Merritt, Dawn A.; Hayes, J. M.; Des Marais, David J.
1995-01-01
Less than 15 min are required for the determination of delta C(sub PDB)-13 with a precision of 0.2 ppt(1 sigma, single measurement) in 5-mL samples of air containing CH4 at natural levels (1.7 ppm). An analytical system including a sample-introduction unit incorporating a preparative gas chromatograph (GC) column for separation of CH4 from N2, O2, and Ar is described. The 15-min procedure includes time for operation of that system, high-resolution chromatographic separation of the CH4, on-line combustion and purification of the products, and isotopic calibration. Analyses of standards demonstrate that systematic errors are absent and that there is no dependence of observed values of delta on sample size. For samples containing 100 ppm or more CH4, preconcentration is not required and the analysis time is less than 5 min. The system utilizes a commercially available, high-sensitivity isotope-ratio mass spectrometer. For optimal conditions of smaple handling and combustion, performance of the system is within a factor of 2 of the shot-noise limit. The potential exists therefore for analysis of samples as small as 15 pmol CH4 with a standard deviation of less than 1 ppt.
Goraya, Rajpreet Kaur; Bajwa, Usha
2018-05-01
Inclusion of processed amla have been found to enhance the functional properties and nutritional value of ice cream by augmenting the fiber content, total phenols, tannins, ascorbic acid and antioxidant activity. The present investigation assessed the changes in these constituents, color values (L, a* and b*), melting rate, sensory scores and microbiological quality of ice cream containing amla shreds, pulp, preserve, candy and powder during 60 days' storage at - 18 to - 20 °C. The total solids increased slightly whereas the antioxidant activity, total phenols, ascorbic acid and tannins decreased on storage. The L values declined whereas a* and b* values amplified, the rate of change being highest in candy containing sample followed by preserve. The first drip time of all the samples increased whereas melting rate decreased. The overall acceptability scores declined non significantly. Standard plate count of all the ice cream samples decreased significantly whereas yeast and molds were not detected throughout the storage. The psychrophiles were not spotted up to 30 days, thereafter, a small increase was observed.
Luckwell, Jacquelynn; Denniff, Philip; Capper, Stephen; Michael, Paul; Spooner, Neil; Mallender, Philip; Johnson, Barry; Clegg, Sarah; Green, Mark; Ahmad, Sheelan; Woodford, Lynsey
2013-11-01
To ensure that PK data generated from DBS samples are of the highest quality, it is important that the paper substrate is uniform and does not unduly contribute to variability. This study investigated any within and between lot variations for four cellulose paper types: Whatman™ FTA(®) DMPK-A, -B and -C, and 903(®) (GE Healthcare, Buckinghamshire, UK). The substrates were tested to demonstrate manufacturing reproducibility (thickness, weight, chemical coating concentration) and its effect on the size of the DBS produced, and the quantitative data derived from the bioanalysis of human DBS samples containing six compounds of varying physicochemical properties. Within and between lot variations in paper thickness, mass and chemical coating concentration were within acceptable manufacturing limits. No variation in the spot size or bioanalytical data was observed. Bioanalytical results obtained for DBS samples containing a number of analytes spanning a range of chemical space are not affected by the lot used or by the location within a lot.
Gravity Effects on Combustion Synthesis of Glasses
NASA Technical Reports Server (NTRS)
Yi, H. C.; Guigne, J. Y.; Moore, J. J.; Robinson, L. A.; Manerbino, A. R.; Schowengerdt, F. D.; Gokoglu, S. (Technical Monitor)
2000-01-01
The Combustion Synthesis technique has been used to produce glasses based on B2O3-Al2O3-MgO and CaO-Al2O3. The combustion characteristics of these combustion synthesis reactions using both small cylindrical pellets (SCP) and large spherical pellets (LSP) are presented. Low density pellets (approx. 35% of their theoretical density) were used, which made synthesis of low exothermic combustion reactions possible. Microstructural analysis of reacted samples was carried out to identify the glass-forming compositions. The effects of gravity on the glass formation were studied aboard the KC-135 using SCP samples. Gravity seemed to have such obvious effects on the combustion characteristics that the wave velocity was lower and the Width of the combustion wave was larger under reduced gravity conditions. Samples produced under low gravity also had more enhanced vitrification than those on ground, while some systems also exhibited lower combustion temperatures. It was also found that the container significantly affects both the combustion characteristics and microstructure. Substantially more divitrification occurred at the area which was in contact with the support (container).
Oxidation of pyrite in coal to magnetite
Thorpe, A.N.; Senftle, F.E.; Alexander, C.C.; Dulong, F.T.
1984-01-01
When bituminous coal is heated in an inert atmosphere (He) containing small amounts of oxygen at 393-455 ??C, pyrite (FeS2) in coal is partially converted to magnetite (Fe304). The maximum amount of Fe304 formed during the time of heating corresponds to 5-20% of the total pyrite present, depending on the coal sample. The magnetite forms as an outer crust on the pyrite grains. The fact that the magnetic properties of the pyrite grains are substantially increased by the magnetite crust suggests that pyrite can be separated from coal by use of a low magnetic field. In a laboratory test, 75% removal is obtained by means of a 500 Oe magnet on three samples, and 60% on a fourth sample. ?? 1984.
Pollastro, R.M.
1982-01-01
Extremely well-oriented clay mineral mounts for X-ray diffraction analysis can be prepared quickly and without introducing segregation using the filter-membrane peel technique. Mounting problems encountered with smectite-rich samples can be resolved by using minimal sample and partial air-drying of the clay film before transfer to a glass slide. Samples containing small quantities of clay can produce useful oriented specimens if Teflon masks having more restrictive areas are inserted above the membrane filter during clay deposition. War]page and thermal shock of glass slides can be controlled by using a flat, porous, ceramic plate as a holding surface during heat treatments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Legvold, S.; Burgardt, P.; Beaudry, B.J.
1977-09-15
The electrical resistivity of high-purity double hexagonal-close-packed (dhcp) ..cap alpha..-La from 5 to 300 K is reported. Measurements were made on small-grained samples prepared by heat treatment of cold-worked lanthanum. Measurements were also made on samples cut in different directions from an ingot slowly cooled from the molten state. The room-temperature results were all within 2% of the mean value. Chemically pure ..beta..-La (fcc) cannot be retained at room temperature, hence, measurements were made on an fcc sample of La containing 0.2-at. % Gd and approx. 0.8-at. % total interstitial nonmetallic impurities. The cubic form has almost the same typemore » of temperature dependence as the dhcp form, but has a 10% lower magnitude.« less
Cortez, Juliana; Pasquini, Celio
2013-02-05
The ring-oven technique, originally applied for classical qualitative analysis in the years 1950s to 1970s, is revisited to be used in a simple though highly efficient and green procedure for analyte preconcentration prior to its determination by the microanalytical techniques presently available. The proposed preconcentration technique is based on the dropwise delivery of a small volume of sample to a filter paper substrate, assisted by a flow-injection-like system. The filter paper is maintained in a small circular heated oven (the ring oven). Drops of the sample solution diffuse by capillarity from the center to a circular area of the paper substrate. After the total sample volume has been delivered, a ring with a sharp (c.a. 350 μm) circular contour, of about 2.0 cm diameter, is formed on the paper to contain most of the analytes originally present in the sample volume. Preconcentration coefficients of the analyte can reach 250-fold (on a m/m basis) for a sample volume as small as 600 μL. The proposed system and procedure have been evaluated to concentrate Na, Fe, and Cu in fuel ethanol, followed by simultaneous direct determination of these species in the ring contour, employing the microanalytical technique of laser induced breakdown spectroscopy (LIBS). Detection limits of 0.7, 0.4, and 0.3 μg mL(-1) and mean recoveries of (109 ± 13)%, (92 ± 18)%, and (98 ± 12)%, for Na, Fe, and Cu, respectively, were obtained in fuel ethanol. It is possible to anticipate the application of the technique, coupled to modern microanalytical and multianalyte techniques, to several analytical problems requiring analyte preconcentration and/or sample stabilization.
Sproul, John S; Maddison, David R
2017-11-01
Despite advances that allow DNA sequencing of old museum specimens, sequencing small-bodied, historical specimens can be challenging and unreliable as many contain only small amounts of fragmented DNA. Dependable methods to sequence such specimens are especially critical if the specimens are unique. We attempt to sequence small-bodied (3-6 mm) historical specimens (including nomenclatural types) of beetles that have been housed, dried, in museums for 58-159 years, and for which few or no suitable replacement specimens exist. To better understand ideal approaches of sample preparation and produce preparation guidelines, we compared different library preparation protocols using low amounts of input DNA (1-10 ng). We also explored low-cost optimizations designed to improve library preparation efficiency and sequencing success of historical specimens with minimal DNA, such as enzymatic repair of DNA. We report successful sample preparation and sequencing for all historical specimens despite our low-input DNA approach. We provide a list of guidelines related to DNA repair, bead handling, reducing adapter dimers and library amplification. We present these guidelines to facilitate more economical use of valuable DNA and enable more consistent results in projects that aim to sequence challenging, irreplaceable historical specimens. © 2017 John Wiley & Sons Ltd.
Ford poses at the FIR/LMM/ACE in the U.S. Laboratory
2013-02-21
ISS034-E-056144 (21 Feb. 2013) --- Inside the U.S. Laboratory (Destiny) aboard the Earth-orbiting International Space Statio, NASA astronaut Kevin Ford, Expedition 34 commander, is seen with the Fluids Integration Rack (FIR)/Light Microscopy Module (LMM)/Advanced Colloids Experiment (ACE). ACE samples, which produce microscopic images of materials containing small colloidal particles, are scheduled for arrival on SpaceX-2 in the first week of March.
TNO/Centaurs grouping tested with asteroid data sets
NASA Astrophysics Data System (ADS)
Fulchignoni, M.; Birlan, M.; Barucci, M. A.
2001-11-01
Recently, we have discussed the possible subdivision in few groups of a sample of 22 TNO and Centaurs for which the BVRIJ photometry were available (Barucci et al., 2001, A&A, 371,1150). We obtained this results using the multivariate statistics adopted to define the current asteroid taxonomy, namely the Principal Components Analysis and the G-mode method (Tholen & Barucci, 1989, in ASTEROIDS II). How these methods work with a very small statistical sample as the TNO/Centaurs one? Theoretically, the number of degrees of freedom of the sample is correct. In fact it is 88 in our case and have to be larger then 50 to cope with the requirements of the G-mode. Does the random sampling of the small number of members of a large population contain enough information to reveal some structure in the population? We extracted several samples of 22 asteroids out of a data-base of 86 objects of known taxonomic type for which BVRIJ photometry is available from ECAS (Zellner et al. 1985, ICARUS 61, 355), SMASS II (S.W. Bus, 1999, PhD Thesis, MIT), and the Bell et al. Atlas of the asteroid infrared spectra. The objects constituting the first sample were selected in order to give a good representation of the major asteroid taxonomic classes (at least three samples each class): C,S,D,A, and G. Both methods were able to distinguish all these groups confirming the validity of the adopted methods. The S class is hard to individuate as a consequence of the choice of I and J variables, which imply a lack of information on the absorption band at 1 micron. The other samples were obtained by random choice of the objects. Not all the major groups were well represented (less than three samples per groups), but the general trend of the asteroid taxonomy has been always obtained. We conclude that the quoted grouping of TNO/Centaurs is representative of some physico-chemical structure of the outer solar system small body population.
A vastly improved method for in situ stable isotope analysis of very small water samples.
NASA Astrophysics Data System (ADS)
Coleman, M. L.; Christensen, L. E.; Kriesel, J.; Kelly, J.; Moran, J.; Vance, S.
2016-12-01
The stable isotope compositions of hydrogen and oxygen in water, ice and hydrated minerals are key characteristics to determine the origin and history of the material. Originally, analyses were performed by separating hydrogen and preparing CO2 from the oxygen in water for stable isotope ratio mass spectrometry. Subsequently, infrared absorption spectrometry in either a Herriot cell or by cavity ring down allowed direct analysis of water vapor. We are developing an instrument, intended for spaceflight and in situ deployment, which will exploit Capillary Absorption Spectrometry (CAS) for the H and O isotope analysis and a laser to sample planetary ices and hydrated minerals. The Tunable Laser Spectrometer (TLS) instrument (part of SAM on the MSL rover Curiosity) works by infrared absorption and we use its performance as a benchmark for comparison. TLS has a relatively large sample chamber to contain mirrors which give a long absorption pathlength. CAS works on the same principle but utilizes a hollow optic fiber, greatly reducing the sample volume. The fiber is a waveguide, enhancing the laser - water-vapor interaction and giving more than four orders of magnitude increase in sensitivity, despite a shorter optical path length. We have calculated that a fiber only 2 m long will be able to analyze 5 nanomoles of water with a precision of less than 1 per mil for D?H. The fiber is coiled to minimize instrument volume. Our instrument will couple this analytical capability with laser sampling to free water from hydrated minerals and ice and ideally we would use the same laser via a beam-splitter both for sampling and analysis. The ability to analyze very small samples is of benefit in two ways. In this concept it will allow much faster analysis of small sub-samples, while the high spatial sampling resolution offered by the laser will allow analysis of the heterogeneity of isotopic composition within grains or crystals, revealing the history of their growth.
Method for preparing small volume reaction containers
Retterer, Scott T.; Doktycz, Mitchel J.
2017-04-25
Engineered reaction containers that can be physically and chemically defined to control the flux of molecules of different sizes and charge are disclosed. Methods for constructing small volume reaction containers through a combination of etching and deposition are also disclosed. The methods allow for the fabrication of multiple devices that possess features on multiple length scales, specifically small volume containers with controlled porosity on the nanoscale.
Planetary Sample Caching System Design Options
NASA Technical Reports Server (NTRS)
Collins, Curtis; Younse, Paulo; Backes, Paul
2009-01-01
Potential Mars Sample Return missions would aspire to collect small core and regolith samples using a rover with a sample acquisition tool and sample caching system. Samples would need to be stored in individual sealed tubes in a canister that could be transfered to a Mars ascent vehicle and returned to Earth. A sample handling, encapsulation and containerization system (SHEC) has been developed as part of an integrated system for acquiring and storing core samples for application to future potential MSR and other potential sample return missions. Requirements and design options for the SHEC system were studied and a recommended design concept developed. Two families of solutions were explored: 1)transfer of a raw sample from the tool to the SHEC subsystem and 2)transfer of a tube containing the sample to the SHEC subsystem. The recommended design utilizes sample tool bit change out as the mechanism for transferring tubes to and samples in tubes from the tool. The SHEC subsystem design, called the Bit Changeout Caching(BiCC) design, is intended for operations on a MER class rover.
Regalado, Erik L; Zhuang, Ping; Chen, Yadan; Makarov, Alexey A; Schafer, Wes A; McGachy, Neil; Welch, Christopher J
2014-01-07
In recent years, the use of halogen-containing molecules has proliferated in the pharmaceutical industry, where the incorporation of halogens, especially fluorine, has become vitally important for blocking metabolism and enhancing the biological activity of pharmaceuticals. The chromatographic separation of halogen-containing pharmaceuticals from associated isomers or dehalogenation impurities can sometimes be quite difficult. In an attempt to identify the best current tools available for addressing this important problem, a survey of the suitability of four chromatographic method development platforms (ultra high-performance liquid chromatography (UHPLC), core shell HPLC, achiral supercritical fluid chromatography (SFC) and chiral SFC) for separating closely related mixtures of halogen-containing pharmaceuticals and their dehalogenated isosteres is described. Of the 132 column and mobile phase combinations examined for each mixture, a small subset of conditions were found to afford the best overall performance, with a single UHPLC method (2.1 × 50 mm, 1.9 μm Hypersil Gold PFP, acetonitrile/methanol based aqueous eluents containing either phosphoric or perchloric acid with 150 mM sodium perchlorate) affording excellent separation for all samples. Similarly, a survey of several families of closely related halogen-containing small molecules representing the diversity of impurities that can sometimes be found in purchased starting materials for synthesis revealed chiral SFC (Chiralcel OJ-3 and Chiralpak IB, isopropanol or ethanol with 25 mM isobutylamine/carbon dioxide) as well as the UHPLC (2.1 × 50 mm, 1.8 μm ZORBAX RRHD Eclipse Plus C18 and the Gold PFP, acetonitrile/methanol based aqueous eluents containing phosphoric acid) as preferred methods.
Svedberg, Urban; Johanson, Gunnar
2017-03-01
Containerized cargo shipment makes up the backbone of international trade. The principal aim of this cross-sectional study was to establish a qualitative and quantitative description of gaseous fumigants and volatile off-gassing substances facing workers tasked with entering shipping containers. A total of 372 packed and 119 empty shipping containers were sampled in six ports and two distribution centers in Sweden. Fourier-transform infrared spectrometry (FTIR) and photoionization detection (PID) were the analytical methods applied to the bulk of samples. A small number of adsorbent samples were analyzed using gas chromatography-mass spectrometry (GC-MS). The results were compared to Swedish occupational exposure limits (OELs), the closest parallel to relevant work situations. Based on the FTIR analyses, 30 of 249 (12%) containers arrived with concentrations of fumigants and off-gassing substances above the 8-h OELs and close to 7% were above the short-term exposure limits. Eight detected chemicals were classified as carcinogens and 4% of the containers arrived with levels of carcinogens above the OELs, at a maximum 30 times the 8-h OEL. Considerable differences were observed between ports, ranging from 0 to 33% of containers arriving with concentrations above the OELs. It is believed that all observation results, apart from a single instance of a confirmed fumigant, phosphine, at 3 p.p.m., and possibly three instances of carbon dioxide, can be attributed to off-gassing substances. The FTIR methodology proved useful for quick preliminary checks and in-depth screening and identification. The PID method produced both false-negative and false-positive results where only 48% matched the FTIR observations. Adsorbent sampling with GC-MS analysis was useful for confirming volatile organic compounds but was deemed too slow for day-to-day screening. The high frequency of contaminated containers, the detection of several carcinogens, and the sporadic occurrences of high levels of fumigants are serious concerns that need to be properly recognized in order to protect the workers at risk. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Tzanidakis, Nikolaos; Maksimov, Pavlo; Conraths, Franz J; Kiossis, Evaggelos; Brozos, Christos; Sotiraki, Smaragda; Schares, Gereon
2012-12-21
Sheep and goats are highly susceptible for infections with Toxoplasma gondii and may play a major role in the transmission of toxoplasmosis to humans. The aim of this study was to obtain up-to-date data on T. gondii infection in small ruminants and to identify putative risk factors in sheep and goats reared under dairy husbandry systems most commonly applied in Greece. To this end, ELISA tests were established for the examination of sheep and goat sera based on the use of TgSAG1, a major surface antigen of T. gondii tachyzoites. Serum samples from 2-4 years old small ruminants, 1501 from sheep and 541 from goats were examined. These samples had been collected on 69 farms in a mountainous and in a costal environment of Northern Greece from September 2008 to January 2009. In addition to farms containing only sheep (n=28) and farms containing only goats (n=9) also mixed farms with both animal species (n=32) were sampled. A standardized questionnaire was used to obtain information on putative risk factors. Sheep showed a higher seroprevalence (48.6% [729/1501]) for T. gondii than goats (30.7% [166/541]). Univariate multi-level modelling assuming random effects by the factor "farm" revealed that goats were statistically significantly less often seropositive than sheep (OR 0.475 [95% CI: 0.318-0.707]). No statistically significant regional differences in seroprevalence were observed. Risk factor analysis using univariate multi-level modelling revealed that sheep and goats that were kept under intensive (OR 4.30 [95% CI: 1.39-13.27]) or semi-intensive (OR 5.35 [95% CI: 2.33-12.28]) conditions had significantly higher odds of being seropositive. Further significant risk factors were "feeding concentrate" (OR 3.88 [95% CI: 1.81-8.29]) and providing "water from the public supply" (OR 1.67 [95% CI: 4.56-12.39]) to small ruminants. Copyright © 2012 Elsevier B.V. All rights reserved.
Semenistaya, Ekaterina; Zvereva, Irina; Krotov, Grigory; Rodchenkov, Grigory
2016-09-01
Currently liquid chromatography - mass spectrometry (LC-MS) analysis after solid-phase extraction (SPE) on weak cation-exchange cartridges is a method of choice for anti-doping analysis of small bioactive peptides such as growth hormone releasing peptides (GHRPs), desmoporessin, LHRH, and TB-500 short fragment. Dilution of urine samples with phosphate buffer for pH adjustment and SPE on weak cation exchange microelution plates was tested as a means to increase throughput of this analysis. Dilution using 200 mM phosphate buffer provides good buffering capacity without affecting the peptides recoveries. SPE on microelution plates was performed on Waters Positive Pressure-96 Processor with subsequent evaporation of eluates in nitrogen flow. Though the use of smaller sample volume decreases the pre-concentration factor and increases the limits of detection of 5 out of 17 detected peptides, the recovery, linearity, and reproducibility of the microelution extraction were comparable with cartridge SPE. The effectiveness of protocols was confirmed by analysis of urine samples containing ipamorelin, and GHRP-6 and its metabolites. SPE after urine sample dilution with buffer can be used for faster sample preparation. The use of microelution plates decreases consumption of solvents and allows processing of up to 96 samples simultaneously. Cartridge SPE with manual рН adjustment remains the best option for confirmation. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Differential expression analysis for RNAseq using Poisson mixed models.
Sun, Shiquan; Hood, Michelle; Scott, Laura; Peng, Qinke; Mukherjee, Sayan; Tung, Jenny; Zhou, Xiang
2017-06-20
Identifying differentially expressed (DE) genes from RNA sequencing (RNAseq) studies is among the most common analyses in genomics. However, RNAseq DE analysis presents several statistical and computational challenges, including over-dispersed read counts and, in some settings, sample non-independence. Previous count-based methods rely on simple hierarchical Poisson models (e.g. negative binomial) to model independent over-dispersion, but do not account for sample non-independence due to relatedness, population structure and/or hidden confounders. Here, we present a Poisson mixed model with two random effects terms that account for both independent over-dispersion and sample non-independence. We also develop a scalable sampling-based inference algorithm using a latent variable representation of the Poisson distribution. With simulations, we show that our method properly controls for type I error and is generally more powerful than other widely used approaches, except in small samples (n <15) with other unfavorable properties (e.g. small effect sizes). We also apply our method to three real datasets that contain related individuals, population stratification or hidden confounders. Our results show that our method increases power in all three data compared to other approaches, though the power gain is smallest in the smallest sample (n = 6). Our method is implemented in MACAU, freely available at www.xzlab.org/software.html. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.
International Agreement on Planetary Protection
NASA Technical Reports Server (NTRS)
2000-01-01
The maintenance of a NASA policy, is consistent with international agreements. The planetary protection policy management in OSS, with Field Center support. The advice from internal and external advisory groups (NRC, NAC/Planetary Protection Task Force). The technology research and standards development in bioload characterization. The technology research and development in bioload reduction/sterilization. This presentation focuses on: forward contamination - research on the potential for Earth life to exist on other bodies, improved strategies for planetary navigation and collision avoidance, and improved procedures for sterile spacecraft assembly, cleaning and/or sterilization; and backward contamination - development of sample transfer and container sealing technologies for Earth return, improvement in sample return landing target assessment and navigation strategy, planning for sample hazard determination requirements and procedures, safety certification, (liaison to NEO Program Office for compositional data on small bodies), facility planning for sample recovery system, quarantine, and long-term curation of 4 returned samples.
Carbon-14 in methane sources and in atmospheric methane - The contribution from fossil carbon
NASA Technical Reports Server (NTRS)
Wahlen, M.; Tanaka, N.; Henry, R.; Deck, B.; Zeglen, J.
1989-01-01
Measurements of carbon-14 in small samples of methane from major biogenic sources, from biomass burning, and in clean air samples from both the Northern and Southern hemispheres reveal that methane from ruminants contains contemporary carbon, whereas that from wetlands, peat bogs, rice fields, and tundra, is somewhat depleted in carbon-14. Atmospheric (C-14)H4 seems to have increased from 1986 to 1987, and levels at the end of 1987 were 123.3 + or - 0.8 percent modern carbon in the Northern Hemisphere and 120.0 + or - 0.7 percent modern carbon in the Southern Hemisphere.
Megchelenbrink, Wout; Huynen, Martijn; Marchiori, Elena
2014-01-01
Constraint-based models of metabolic networks are typically underdetermined, because they contain more reactions than metabolites. Therefore the solutions to this system do not consist of unique flux rates for each reaction, but rather a space of possible flux rates. By uniformly sampling this space, an estimated probability distribution for each reaction's flux in the network can be obtained. However, sampling a high dimensional network is time-consuming. Furthermore, the constraints imposed on the network give rise to an irregularly shaped solution space. Therefore more tailored, efficient sampling methods are needed. We propose an efficient sampling algorithm (called optGpSampler), which implements the Artificial Centering Hit-and-Run algorithm in a different manner than the sampling algorithm implemented in the COBRA Toolbox for metabolic network analysis, here called gpSampler. Results of extensive experiments on different genome-scale metabolic networks show that optGpSampler is up to 40 times faster than gpSampler. Application of existing convergence diagnostics on small network reconstructions indicate that optGpSampler converges roughly ten times faster than gpSampler towards similar sampling distributions. For networks of higher dimension (i.e. containing more than 500 reactions), we observed significantly better convergence of optGpSampler and a large deviation between the samples generated by the two algorithms. optGpSampler for Matlab and Python is available for non-commercial use at: http://cs.ru.nl/~wmegchel/optGpSampler/.
Ogawa, Yuko; Tsujimoto, Masafumi; Yanoshita, Ryohei
2016-01-01
Exosomes are small extracellular vesicles containing microRNAs and mRNAs that are produced by various types of cells. We previously used ultrafiltration and size-exclusion chromatography to isolate two types of human salivary exosomes (exosomes I, II) that are different in size and proteomes. We showed that salivary exosomes contain large repertoires of small RNAs. However, precise information regarding long RNAs in salivary exosomes has not been fully determined. In this study, we investigated the compositions of protein-coding RNAs (pcRNAs) and long non-protein-coding RNAs (lncRNAs) of exosome I, exosome II and whole saliva (WS) by next-generation sequencing technology. Although 11% of all RNAs were commonly detected among the three samples, the compositions of reads mapping to known RNAs were similar. The most abundant pcRNA is ribosomal RNA protein, and pcRNAs of some salivary proteins such as S100 calcium-binding protein A8 (protein S100-A8) were present in salivary exosomes. Interestingly, lncRNAs of pseudogenes (presumably, processed pseudogenes) were abundant in exosome I, exosome II and WS. Translationally controlled tumor protein gene, which plays an important role in cell proliferation, cell death and immune responses, was highly expressed as pcRNA and pseudogenes in salivary exosomes. Our results show that salivary exosomes contain various types of RNAs such as pseudogenes and small RNAs, and may mediate intercellular communication by transferring these RNAs to target cells as gene expression regulators.
Mursch, Kay; Scholz, Martin; Brück, Wolfgang; Behnke-Mursch, Julianne
2017-01-01
The aim of this study was to investigate whether intraoperative ultrasonography (IOUS) helped the surgeon navigate towards the tumor as seen in preoperative magnetic resonance imaging and whether IOUS was able to distinguish between tumor margins and the surrounding tissue. Twenty-five patients suffering from high-grade gliomas who were previously treated by surgery and radiotherapy were included. Intraoperatively, two histopathologic samples were obtained a sample of unequivocal tumor tissue (according to anatomical landmarks and the surgeon's visual and tactile impressions) and a small tissue sample obtained using a navigated needle when the surgeon decided to stop the resection. This specimen was considered to be a boundary specimen, where no tumor tissue was apparent. The decision to take the second sample was not influenced by IOUS. The effect of IOUS was analyzed semi-quantitatively. All 25 samples of unequivocal tumor tissue were histopathologically classified as tumor tissue and were hyperechoic on IOUS. Of the boundary specimens, eight were hypoechoic. Only one harbored tumor tissue (P=0.150). Seventeen boundaries were moderately hyperechoic, and these samples contained all possible histological results (i.e., tumor, infiltration, or no tumor). During surgery performed on relapsed, irradiated, high-grade gliomas, IOUS provided a reliable method of navigating towards the core of the tumor. At borders, it did not reliably distinguish between remnants or tumor-free tissue, but hypoechoic areas seldom contained tumor tissue.
NASA Technical Reports Server (NTRS)
Peters, Gregory
2010-01-01
A field-deployable, battery-powered Rapid Active Sampling Package (RASP), originally designed for sampling strong materials during lunar and planetary missions, shows strong utility for terrestrial geological use. The technology is proving to be simple and effective for sampling and processing materials of strength. Although this originally was intended for planetary and lunar applications, the RASP is very useful as a powered hand tool for geologists and the mining industry to quickly sample and process rocks in the field on Earth. The RASP allows geologists to surgically acquire samples of rock for later laboratory analysis. This tool, roughly the size of a wrench, allows the user to cut away swaths of weathering rinds, revealing pristine rock surfaces for observation and subsequent sampling with the same tool. RASPing deeper (.3.5 cm) exposes single rock strata in-situ. Where a geologist fs hammer can only expose unweathered layers of rock, the RASP can do the same, and then has the added ability to capture and process samples into powder with particle sizes less than 150 microns, making it easier for XRD/XRF (x-ray diffraction/x-ray fluorescence). The tool uses a rotating rasp bit (or two counter-rotating bits) that resides inside or above the catch container. The container has an open slot to allow the bit to extend outside the container and to allow cuttings to enter and be caught. When the slot and rasp bit are in contact with a substrate, the bit is plunged into it in a matter of seconds to reach pristine rock. A user in the field may sample a rock multiple times at multiple depths in minutes, instead of having to cut out huge, heavy rock samples for transport back to a lab for analysis. Because of the speed and accuracy of the RASP, hundreds of samples can be taken in one day. RASP-acquired samples are small and easily carried. A user can characterize more area in less time than by using conventional methods. The field-deployable RASP used a Ni/Cad rechargeable battery. Power usage was less than 1 Wh/ cm3 even when sampling strong basalts, so many samples could be taken on a single battery charge.
NASA Astrophysics Data System (ADS)
Meng, Su; Chen, Jie; Sun, Jian
2017-10-01
This paper investigates the problem of observer-based output feedback control for networked control systems with non-uniform sampling and time-varying transmission delay. The sampling intervals are assumed to vary within a given interval. The transmission delay belongs to a known interval. A discrete-time model is first established, which contains time-varying delay and norm-bounded uncertainties coming from non-uniform sampling intervals. It is then converted to an interconnection of two subsystems in which the forward channel is delay-free. The scaled small gain theorem is used to derive the stability condition for the closed-loop system. Moreover, the observer-based output feedback controller design method is proposed by utilising a modified cone complementary linearisation algorithm. Finally, numerical examples illustrate the validity and superiority of the proposed method.
A curious pellet from a great horned owl (Bubo virginianus)
Woodman, N.; Dove, C.J.; Peurach, S.C.
2005-01-01
One of the traditional methods of determining the dietary preferences of owls relies upon the identification of bony remains of prey contained in regurgitated pellets. Discovery of a pellet containing a large, complete primary feather from an adult, male Ring-necked Pheasant (Phasianus colchicus) prompted us to examine in detail a small sample of pellets from a Great Horned Owl (Bubo virginianus). Our analyses of feather and hair remains in these pellets documented the presence of three species of birds and two species of mammals, whereas bones in the pellets represented only mammals. This finding indicates an important bias that challenges the reliability of owl pellet studies making use of only osteological remains.
Christiansen, Robert M.; Mills, William C.
1992-01-01
The swipe transfer assembly is a mechanical assembly which is used in conjunction with glove boxes and other sealed containments. It is used to pass small samples into or out of glove boxes without an open breach of the containment, and includes a rotational cylinder inside a fixed cylinder, the inside cylinder being rotatable through an arc of approximately 240.degree. relative to the outer cylinder. An offset of 120.degree. from end to end allows only one port to be opened at a time. The assembly is made of stainless steel or aluminum and clear acrylic plastic to enable visual observation. The assembly allows transfer of swipes and smears from radiological and other specially controlled environments.
High-Collection-Efficiency Fluorescence Detection Cell
NASA Technical Reports Server (NTRS)
Hanisco, Thomas; Cazorla, Maria; Swanson, Andrew
2013-01-01
A new fluorescence cell has been developed for the laser induced fluorescence (LIF) detection of formaldehyde. The cell is used to sample a flow of air that contains trace concentrations of formaldehyde. The cell provides a hermetically sealed volume in which a flow of air containing formaldehyde can be illuminated by a laser. The cell includes the optics for transmitting the laser beam that is used to excite the formaldehyde and for collecting the resulting fluorescence. The novelty of the cell is its small size and simple design that provides a more robust and cheaper alternative to the state of the art. Despite its simplicity, the cell provides the same sensitivity to detection as larger, more complicated cells.
2017-01-01
We present a sensor that exploits the phenomenon of upconversion luminescence to detect the presence of specific sequences of small oligonucleotides such as miRNAs among others. The sensor is based on NaYF4:Yb,Er@SiO2 nanoparticles functionalized with ssDNA that contain azide groups on the 3′ ends. In the presence of a target sequence, interstrand ligation is possible via the click-reaction between one azide of the upconversion probe and a DBCO-ssDNA-biotin probe present in the solution. As a result of this specific and selective process, biotin is covalently attached to the surface of the upconversion nanoparticles. The presence of biotin on the surface of the nanoparticles allows their selective capture on a streptavidin-coated support, giving a luminescent signal proportional to the amount of target strands present in the test samples. With the aim of studying the analytical properties of the sensor, total RNA samples were extracted from healthy mosquitoes and were spiked-in with a specific target sequence at different concentrations. The result of these experiments revealed that the sensor was able to detect 10–17 moles per well (100 fM) of the target sequence in mixtures containing 100 ng of total RNA per well. A similar limit of detection was found for spiked human serum samples, demonstrating the suitability of the sensor for detecting specific sequences of small oligonucleotides under real conditions. In contrast, in the presence of noncomplementary sequences or sequences having mismatches, the luminescent signal was negligible or conspicuously reduced. PMID:28332400
Wu, Maoxin; Gordon, Ronald E.; Herbert, Robin; Padilla, Maria; Moline, Jacqueline; Mendelson, David; Litle, Virginia; Travis, William D.; Gil, Joan
2010-01-01
Context After the collapse of the World Trade Center (WTC) on 11 September 2001, a dense cloud of dust containing high levels of airborne pollutants covered Manhattan and parts of Brooklyn, New York. Between 60,000 and 70,000 responders were exposed. Many reported adverse health effects. Case presentation In this report we describe clinical, pathologic, and mineralogic findings in seven previously healthy responders who were exposed to WTC dust on either 11 September or 12 September 2001, who developed severe respiratory impairment or unexplained radiologic findings and underwent video-assisted thoracoscopic surgical lung biopsy procedures at Mount Sinai Medical Center. WTC dust samples were also examined. We found that three of the seven responders had severe or moderate restrictive disease clinically. Histopathology showed interstitial lung disease consistent with small airways disease, bronchiolocentric parenchymal disease, and nonnecrotizing granulomatous condition. Tissue mineralogic analyses showed variable amounts of sheets of aluminum and magnesium silicates, chrysotile asbestos, calcium phosphate, and calcium sulfate. Small shards of glass containing mostly silica and magnesium were also found. Carbon nanotubes (CNT) of various sizes and lengths were noted. CNT were also identified in four of seven WTC dust samples. Discussion These findings confirm the previously reported association between WTC dust exposure and bronchiolar and interstitial lung disease. Long-term monitoring of responders will be needed to elucidate the full extent of this problem. The finding of CNT in both WTC dust and lung tissues is unexpected and requires further study. PMID:20368128
Priest, Sheryln; Stamey, Timothy C.; Lawrence, Stephen J.
2002-01-01
In September 2001, the U.S. Geological Survey, in cooperation with the Environmental and Natural Resources Management Office of the U.S. Army Signal Center and Fort Gordon (U.S. Department of the Army), conducted a chemical assessment of surface water, streambed-interstitial water, and bed sediments within the small arms impact area of Fort Gordon Military Installation. The study was conducted in support of the development of an Integrated Natural Resources Management Plan (INRMP) for Fort Gordon, Georgia. An effective INRMP ensures that natural resources conservation measures and U.S. Army activities on the military base are integrated and consistent with Federal requirements to manage military installations on an ecosystem basis. Filtered water samples were collected from five sites along South Prong Creek and three sites along Marcum Branch Creek for chemical analyses of major ions, nutrients, and selected trace elements. On-site measurements of pH, temperature, specific conductance, and dissolved oxygen were made at the eight sites. Filtered water collected showed varying concentrations in both surface- and streambed-interstitial water. Bed-sediment samples collected from South Prong Creek contain elevated levels of arsenic, barium, beryllium, cadmium, chromium, cobalt, copper, iron, lead, manganese, nickel, selenium, vanadium, and total organic carbon relative to previous concentrations (McConnell and others, 2000). Bed-sediment samples collected from Marcum Branch Creek contain elevated levels of beryllium, copper, lead, manganese, mercury, selenium, and total organic carbon relative to previous concentrations (McConnell and others, 2000).
Exfiltrometer apparatus and method for measuring unsaturated hydrologic properties in soil
Hubbell, Joel M.; Sisson, James B.; Schafer, Annette L.
2006-01-17
Exfiltrometer apparatus includes a container for holding soil. A sample container for holding sample soil is positionable with respect to the container so that the sample soil contained in the sample container is in communication with soil contained in the container. A first tensiometer operatively associated with the sample container senses a surface water potential at about a surface of the sample soil contained in the sample container. A second tensiometer operatively associated with the sample container senses a first subsurface water potential below the surface of the sample soil. A water content sensor operatively associated with the sample container senses a water content in the sample soil. A water supply supplies water to the sample soil. A data logger operatively connected to the first and second tensiometers, and to the water content sensor receives and processes data provided by the first and second tensiometers and by the water content sensor.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-30
... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 52 [EPA-R05-OAR-2012-0073; FRL 9677-3] Approval and Promulgation of Air Quality Implementation Plans; Illinois; Small Container Exemption From VOC Coating Rules...), direct final rule approving a revision to the Illinois SIP that added a ``small container exemption'' for...
40 CFR 265.316 - Disposal of small containers of hazardous waste in overpacked drums (lab packs).
Code of Federal Regulations, 2010 CFR
2010-07-01
... OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Landfills § 265.316 Disposal of small containers of hazardous waste in overpacked drums (lab packs). Small containers of hazardous waste... hazardous waste in overpacked drums (lab packs). 265.316 Section 265.316 Protection of Environment...
40 CFR 264.316 - Disposal of small containers of hazardous waste in overpacked drums (lab packs).
Code of Federal Regulations, 2010 CFR
2010-07-01
... HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Landfills § 264.316 Disposal of small containers of hazardous waste in overpacked drums (lab packs). Small containers of hazardous waste in overpacked... hazardous waste in overpacked drums (lab packs). 264.316 Section 264.316 Protection of Environment...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark, C. Scott, E-mail: clarkcs@ucmail.uc.edu; International POPS Elimination Network; Kumar, Abhay
Paints with high lead concentrations (ppm) continue to be sold around the world in many developing countries and those with economies in transition representing a major preventable environmental health hazard that is being increased as the economies expand and paint consumption is increasing. Prior lead paint testing had been performed in Brazil and India and these countries were selected to examine the impact of a new regulatory limit in Brazil and the impact of efforts of non-governmental organizations and others to stop the use of lead compounds in manufacturing paints. Armenia and Kazakhstan, in Central Asia, were selected because nomore » information on lead concentration in those regions was available, no regulatory activities were evident and non-governmental organizations in the IPEN network were available to participate. Another objective of this research was to evaluate the lead loading (µg/cm{sup 2}) limit determined by X-Ray Fluorescence (XRF) for areas on toys that are too small to obtain a sample of sufficient size for laboratory analysis. The lead concentrations in more than three-fourths of the paints from Armenia and Kazakhstan exceeded 90 ppm, the limit in the United States, and 600 ppm, the limit in Brazil. The percentages were about one-half as high in Brazil and India. The average concentration in paints purchased in Armenia, 25,000 ppm, is among the highest that has been previously reported, that in Kazakhstan, 15,700 ppm, and India, 16,600, about median. The average concentration in Brazil, 5600 ppm, is among the lowest observed. Paints in Brazil that contained an average of 36,000 ppm before the regulatory limit became effective were below detection (<9 ppm) in samples collected in the current study. The lack of any apparent public monitoring of paint lead content as part of regulatory enforcement makes it difficult to determine whether the regulation was a major factor contributing to the decline in lead use in these paints. Using data from the current study and those available from other studies 24 of 28 paints from major brands in India decreased from high concentrations to 90 ppm or lower. Since lead concentrations in golden yellow paints from these brands were found to decrease to ≤90 ppm, it is possible that all 28 of these paints now contain ≤90 ppm since yellow paints usually have the highest lead concentrations. Other brands in Brazil and India that have been analyzed only one time had lead concentrations up to 59,000 ppm and 134,000 ppm, respectively. Less than one-third of the paints had notations on their labels with information about lead content and these were sometimes inaccurate. The label from one brand indicating “no added lead” contained paint with 134,000 ppm lead, the highest found in this study. Three percent (3 of 98) of the paints with surface lead loading that did not exceed 2 µg/cm{sup 2}, the limit established by the Consumer Product Safety Improvement Act for small areas on toys, contained greater than 90 ppm lead and thus were false negatives. Of the new paint samples that contained ≤600 ppm, 88% contained ≤90 ppm. Of the samples that contained ≤90 ppm, 97% contained ≤45 ppm and 92% contained ≤15 ppm. Based on these data it appears to be technically feasible to manufacture paints containing ≤90 ppm and in many cases to produce paints that have lead concentrations that do not exceed 15 ppm. - Highlights: • Brazilian paints with high lead (avg. 36,000 ppm) contained <9 ppm after regulation. • Lead in major Indian paint brands decreased to low levels by efforts of NGOs/others. • Most paints with lead ≤600 ppm also are ≤90 ppm and many also ≤15 ppm. • At the CPSIA limit of 2 µg Pb/cm{sup 2} for small areas on toys, 3% exceeded 90 ppm lead. • Most paint brands in Armenia and Kazakhstan based/manufactured outside the country.« less
High Prevalence of Anaplasma spp. in Small Ruminants in Morocco.
Ait Lbacha, H; Alali, S; Zouagui, Z; El Mamoun, L; Rhalem, A; Petit, E; Haddad, N; Gandoin, C; Boulouis, H-J; Maillard, R
2017-02-01
The prevalence of infection by Anaplasma spp. (including Anaplasma phagocytophilum) was determined using blood smear microscopy and PCR through screening of small ruminant blood samples collected from seven regions of Morocco. Co-infections of Anaplasma spp., Babesia spp, Theileria spp. and Mycoplasma spp. were investigated and risk factors for Anaplasma spp. infection assessed. A total of 422 small ruminant blood samples were randomly collected from 70 flocks. Individual animal (breed, age, tick burden and previous treatment) and flock data (GPS coordinate of farm, size of flock and livestock production system) were collected. Upon examination of blood smears, 375 blood samples (88.9%) were found to contain Anaplasma-like erythrocytic inclusion bodies. Upon screening with a large spectrum PCR targeting the Anaplasma 16S rRNA region, 303 (71%) samples were found to be positive. All 303 samples screened with the A. phagocytophilum-specific PCR, which targets the msp2 region, were found to be negative. Differences in prevalence were found to be statistically significant with regard to region, altitude, flock size, livestock production system, grazing system, presence of clinical cases and application of tick and tick-borne diseases prophylactic measures. Kappa analysis revealed a poor concordance between microscopy and PCR (k = 0.14). Agreement with PCR is improved by considering microscopy and packed cell volume (PCV) in parallel. The prevalence of double infections was found to be 1.7, 2.5 and 24% for Anaplasma-Babesia, Anaplasma-Mycoplasma and Anaplasma-Theileria, respectively. Co-infection with three or more haemoparasites was found in 1.6% of animals examined. In conclusion, we demonstrate the high burden of anaplasmosis in small ruminants in Morocco and the high prevalence of co-infections of tick-borne diseases. There is an urgent need to improve the control of this neglected group of diseases. © 2015 Blackwell Verlag GmbH.
Tourtelot, H.A.
1964-01-01
The composition of nonmarine shales of Cretaceous age that contain less than 1 per cent organic carbon is assumed to represent the inherited minor-element composition of clayey sediments delivered to the Cretaceous sea that occupied the western interior region of North America. Differences in minor-element content between these samples and samples of 1. (a) nonmarine carbonaceous shales (1 to 17 per cent organic carbon), 2. (b) nearshore marine shales (less than 1 per cent organic carbon), and 3. (c) offshore marine shales (as much as 8 per cent organic carbon), all of the same age, reveal certain aspects of the role played by clay minerals and organic materials in affecting the minor-element composition of the rocks. The organic carbon in the nonmarine rocks occurs in disseminated coaly plant remains. The organic carbon in the marine rocks occurs predominantly in humic material derived from terrestrial plants. The close similarity in composition between the organic isolates from the marine samples and low-rank coal suggests that the amount of marine organic material in these rocks is small. The minor-element content of the two kinds of nonmarine shales is the same despite the relatively large amount of organic carbon in the carbonaceous shales. The nearshore marine shales, however, contain larger median amounts of arsenic, boron, chromium, vanadium and zinc than do the nonmarine rocks; and the offshore marine shales contain even larger amounts of these elements. Cobalt, molybdenum, lead and zirconium show insignificant differences in median content between the nonmarine and marine rocks, although as much as 25 ppm molybdenum is present in some offshore marine samples. The gallium content is lower in the marine than in the nonmarine samples. Copper and selenium contents of the two kinds of nonmarine rocks and the nearshore marine samples are the same, but those of the offshore samples are larger. In general, arsenic, chromium, copper, molybdenum, selenium, vanadium and zinc are concentrated in those offshore marine samples having the largest amounts of organic carbon, but samples with equal amounts of vanadium, for instance, may differ by a factor of 3 in their amount of organic carbon. Arsenic and molybdenum occur in some samples chiefly in syngenetic pyrite but also are present in relatively large amounts in samples that contain little pyrite. The data on nonmarine carbonaceous shales indicate that organic matter of terrestrial origin in marine shales contributes little to the minor-element content of such rocks. It is possible that marine organic matter, even though seemingly small in amount in marine shales, contributes to the minor-element composition of the shales. In addition to any such contribution, however, the great effectiveness in sorption processes of humic materials in conjunction with clay minerals suggests that such processes must have played an important role as these materials moved from the relatively dilute solutions of the nonmarine environment to the relatively concentrated solution of sea water. The volumes of sea water sufficient to supply for sorption the amounts of most minor elements in the offshore marine samples are insignificant compared to the volumes of water with which the clay and organic matter were in contact during their transportation and sedimentation. Consequently, the chemical characteristics of the environment in which the clay minerals and organic matter accumulated and underwent diagenesis probably were the most important factors in controlling the degree to which sorption processes and the formation of syngenetic minerals affected the final composition of the rocks. ?? 1969.
Lin, Yiqing; Li, Weiyong; Xu, Jin; Boulas, Pierre
2015-07-05
The aim of this study is to develop an at-line near infrared (NIR) method for the rapid and simultaneous determination of four structurally similar active pharmaceutical ingredients (APIs) in powder blends intended for the manufacturing of tablets. Two of the four APIs in the formula are present in relatively small amounts, one at 0.95% and the other at 0.57%. Such small amounts in addition to the similarity in structures add significant complexity to the blend uniformity analysis. The NIR method is developed using spectra from six laboratory-created calibration samples augmented by a small set of spectra from a large-scale blending sample. Applying the quality by design (QbD) principles, the calibration design included concentration variations of the four APIs and a main excipient, microcrystalline cellulose. A bench-top FT-NIR instrument was used to acquire the spectra. The obtained NIR spectra were analyzed by applying principal component analysis (PCA) before calibration model development. Score patterns from the PCA were analyzed to reveal relationship between latent variables and concentration variations of the APIs. In calibration model development, both PLS-1 and PLS-2 models were created and evaluated for their effectiveness in predicting API concentrations in the blending samples. The final NIR method shows satisfactory specificity and accuracy. Copyright © 2015 Elsevier B.V. All rights reserved.
Neeser, Rudolph; Ackermann, Rebecca Rogers; Gain, James
2009-09-01
Various methodological approaches have been used for reconstructing fossil hominin remains in order to increase sample sizes and to better understand morphological variation. Among these, morphometric quantitative techniques for reconstruction are increasingly common. Here we compare the accuracy of three approaches--mean substitution, thin plate splines, and multiple linear regression--for estimating missing landmarks of damaged fossil specimens. Comparisons are made varying the number of missing landmarks, sample sizes, and the reference species of the population used to perform the estimation. The testing is performed on landmark data from individuals of Homo sapiens, Pan troglodytes and Gorilla gorilla, and nine hominin fossil specimens. Results suggest that when a small, same-species fossil reference sample is available to guide reconstructions, thin plate spline approaches perform best. However, if no such sample is available (or if the species of the damaged individual is uncertain), estimates of missing morphology based on a single individual (or even a small sample) of close taxonomic affinity are less accurate than those based on a large sample of individuals drawn from more distantly related extant populations using a technique (such as a regression method) able to leverage the information (e.g., variation/covariation patterning) contained in this large sample. Thin plate splines also show an unexpectedly large amount of error in estimating landmarks, especially over large areas. Recommendations are made for estimating missing landmarks under various scenarios. Copyright 2009 Wiley-Liss, Inc.
Huckins, J.N.; Petty, J.D.; Orazio, C.E.; Lebo, J.A.; Clark, R.C.; Gibson, V.L.; Gala, W.R.; Echols, K.R.
1999-01-01
The use of lipid-containing semipermeable membrane devices (SPMDs) is becoming commonplace, but very little sampling rate data are available for the estimation of ambient contaminant concentrations from analyte levels in exposed SPMDs. We determined the aqueous sampling rates (R(s)s; expressed as effective volumes of water extracted daily) of the standard (commercially available design) 1-g triolein SPMD for 15 of the priority pollutant (PP) polycyclic aromatic hydrocarbons (PAHs) at multiple temperatures and concentrations. Under the experimental conditions of this study, recovery- corrected R(s) values for PP PAHs ranged from ???1.0 to 8.0 L/d. These values would be expected to be influenced by significant changes (relative to this study) in water temperature, degree of biofouling, and current velocity- turbulence. Included in this paper is a discussion of the effects of temperature and octanol-water partition coefficient (K(ow)); the impacts of biofouling and hydrodynamics are reported separately. Overall, SPMDs responded proportionally to aqueous PAH concentrations; i.e., SPMD R(s) values and SPMD-water concentration factors were independent of aqueous concentrations. Temperature effects (10, 18, and 26 ??C) on Rs values appeared to be complex but were relatively small.The use of lipid-containing semipermeable membrane devices (SPMDs) is becoming commonplace, but very little sampling rate data are available for the estimation of ambient contaminant concentrations from analyte levels in exposed SPMDs. We determined the aqueous sampling rates (Rss; expressed as effective volumes of water extracted daily) of the standard (commercially available design) 1-g triolein SPMD for 15 of the priority pollutant (PP) polycyclic aromatic hydrocarbons (PAHs) at multiple temperatures and concentrations. Under the experimental conditions of this study, recovery-corrected Rs values for PP PAHs ranged from ???1.0 to 8.0 L/d. These values would be expected to be influenced by significant changes (relative to this study) in water temperature, degree of biofouling, and current velocity-turbulence. Included in this paper is a discussion of the effects of temperature and octanol-water partition coefficient (KOW); the impacts of biofouling and hydrodynamics are reported separately. Overall, SPMDs responded proportionally to aqueous PAH concentrations; i.e., SPMD RS values and SPMD-water concentration factors were independent of aqueous concentrations. Temperature effects (10, 18, and 26??C) on RS values appeared to be complex but were relatively small.
Ground-water resources of the lower Niobrara River and Ponca Creek basins, Nebraska and South Dakota
Newport, Thomas G.; Krieger, Robert A.
1959-01-01
The report contains an annotated bibliography of previous publications on the geology and ground-water resources of the area, brief descriptions of the Cretaceous, Tertiary, and Quaternary rocks, a map showing the contour of the water table, logs of test holes and wells not published elsewhere, results of analyses of ground- and surface-water samples, and records of all wells of large discharge and representative wells of small discharge.
Slimani, Sami; Robyns, Audrey; Jarraud, Sophie; Molmeret, Maëlle; Dusserre, Eric; Mazure, Céline; Facon, Jean Pierre; Lina, Gérard; Etienne, Jerome; Ginevra, Christophe
2012-02-01
A PMA (propidium monoazide) pretreatment protocol, in which PMA is applied directly to membrane filters, was developed for the PCR-based quantification (PMA-qPCR) of viable Legionella pneumophila. Using this method, the amplification of DNA from membrane-damaged L. pneumophila was strongly inhibited for samples containing a small number of dead bacteria. Copyright © 2011 Elsevier B.V. All rights reserved.
Soluble arabinoxylan alters digesta flow and protein digestion of red meat-containing diets in pigs.
Zhang, Dagong; Williams, Barbara A; Mikkelsen, Deirdre; Li, Xiuhua; Keates, Helen L; Lisle, Allan T; Collins, Helen M; Fincher, Geoffrey B; Bird, Anthony R; Topping, David L; Gidley, Michael J; Bryden, Wayne L
2015-09-01
The aim of this study was to investigate how a moderate increase in dietary meat content combined (or not) with soluble fibre would influence protein digestion as well as digesta characteristics and flow. Four groups of pigs were fed Western-style diets (high-protein/high-fat) containing two types of barbecued red meat, one with and one without a wheat arabinoxylan-rich fraction. After 4 wk, digesta samples were collected from small and large intestinal sites and analyzed for protein, amino acids, dry matter, and acid-insoluble ash. Tissue samples were also collected from each site. Arabinoxylan consumption led to somewhat lower apparent protein digestibility within the small and large intestines as well as shorter mean retention times. This suggests that the lowered protein digestibility is due, at least partly, to shorter access time to digestive proteases and absorptive surfaces. Additionally, digesta mass was higher in pigs fed arabinoxylan while dry matter (%) was lower, indicating an increased digesta water-holding capacity due to the presence of a soluble dietary fiber. Data showed that solubilized wheat arabinoxylan provides potential health benefits through decreased protein digestibility, increased digesta mass, and reduced mean retention time, even for diets with a moderately higher protein content. These factors are associated with efficiency of digestion and satiety, both of which have implications for prevention of obesity and other health disorders. Copyright © 2015 Elsevier Inc. All rights reserved.
Chian, Chih-Feng; Hwang, Yi-Ting; Terng, Harn-Jing; Lee, Shih-Chun; Chao, Tsui-Yi; Chang, Hung; Ho, Ching-Liang; Wu, Yi-Ying; Perng, Wann-Cherng
2016-08-02
Peripheral blood mononuclear cell (PBMC)-derived gene signatures were investigated for their potential use in the early detection of non-small cell lung cancer (NSCLC). In our study, 187 patients with NSCLC and 310 age- and gender-matched controls, and an independent set containing 29 patients for validation were included. Eight significant NSCLC-associated genes were identified, including DUSP6, EIF2S3, GRB2, MDM2, NF1, POLDIP2, RNF4, and WEE1. The logistic model containing these significant markers was able to distinguish subjects with NSCLC from controls with an excellent performance, 80.7% sensitivity, 90.6% specificity, and an area under the receiver operating characteristic curve (AUC) of 0.924. Repeated random sub-sampling for 100 times was used to validate the performance of classification training models with an average AUC of 0.92. Additional cross-validation using the independent set resulted in the sensitivity 75.86%. Furthermore, six age/gender-dependent genes: CPEB4, EIF2S3, GRB2, MCM4, RNF4, and STAT2 were identified using age and gender stratification approach. STAT2 and WEE1 were explored as stage-dependent using stage-stratified subpopulation. We conclude that these logistic models using different signatures for total and stratified samples are potential complementary tools for assessing the risk of NSCLC.
The use of secondary ion mass spectrometry in forensic analyses of ultra-small samples
NASA Astrophysics Data System (ADS)
Cliff, John
2010-05-01
It is becoming increasingly important in forensic science to perform chemical and isotopic analyses on very small sample sizes. Moreover, in some instances the signature of interest may be incorporated in a vast background making analyses impossible by bulk methods. Recent advances in instrumentation make secondary ion mass spectrometry (SIMS) a powerful tool to apply to these problems. As an introduction, we present three types of forensic analyses in which SIMS may be useful. The causal organism of anthrax (Bacillus anthracis) chelates Ca and other metals during spore formation. Thus, the spores contain a trace element signature related to the growth medium that produced the organisms. Although other techniques have been shown to be useful in analyzing these signatures, the sample size requirements are generally relatively large. We have shown that time of flight SIMS (TOF-SIMS) combined with multivariate analysis, can clearly separate Bacillus sp. cultures prepared in different growth media using analytical spot sizes containing approximately one nanogram of spores. An important emerging field in forensic analysis is that of provenance of fecal pollution. The strategy of choice for these analyses-developing host-specific nucleic acid probes-has met with considerable difficulty due to lack of specificity of the probes. One potentially fruitful strategy is to combine in situ nucleic acid probing with high precision isotopic analyses. Bulk analyses of human and bovine fecal bacteria, for example, indicate a relative difference in d13C content of about 4 per mil. We have shown that sample sizes of several nanograms can be analyzed with the IMS 1280 with precisions capable of separating two per mil differences in d13C. The NanoSIMS 50 is capable of much better spatial resolution than the IMS 1280, albeit at a cost of analytical precision. Nevertheless we have documented precision capable of separating five per mil differences in d13C using analytical spots containing less than 300 picograms of bacteria. Perhaps the most successful application of SIMS for forensic purposes to date is in the field of nuclear forensics. An example that has been used by laboratories associated with the International Atomic Energy Agency is the examination of environmental samples for enriched uranium particles indicative of clandestine weapons production activities.. The analytical challenge in these types of measurements is to search complex environmental matrices for U-bearing particles which must then be analyzed for 234U, 235U, and 236U content with high precision and accuracy. Older-generation SIMS instruments were hampered by small geometries that made resolution of significant interferences problematic. In addition, automated particle search software was proprietary and difficult to obtain. With the development of new search software, the IMS 1280 is capable of searching a sample in a matter of hours, flagging U-bearing particles for later analyses, and providing a rough 235U content. Particles of interest can be revisited for high precision analyses, and all U-isotopes can be measured simultaneously in multicollector mode, dramatically improving analysis time and internal precision. Further, the large geometry of the instrument allows complete resolution of isobaric interferences that have traditionally limited SIMS analyses of difficult samples. Examples of analyses of micron-sized standard particles indicate that estimates of 235U enrichment can be obtained with an external relative precision of 0.1% and 234U and 236U contents can be obtained with a relative precision of less than 1%. Analyses of 'real' samples show a dramatic improvement in the data quality obtained compared with small-geometry SIMS instruments making SIMS the method of choice for these high-profile samples when accurate, precise, and rapid results are required.
Probing the Small-scale Structure in Strongly Lensed Systems via Transdimensional Inference
NASA Astrophysics Data System (ADS)
Daylan, Tansu; Cyr-Racine, Francis-Yan; Diaz Rivero, Ana; Dvorkin, Cora; Finkbeiner, Douglas P.
2018-02-01
Strong lensing is a sensitive probe of the small-scale density fluctuations in the Universe. We implement a pipeline to model strongly lensed systems using probabilistic cataloging, which is a transdimensional, hierarchical, and Bayesian framework to sample from a metamodel (union of models with different dimensionality) consistent with observed photon count maps. Probabilistic cataloging allows one to robustly characterize modeling covariances within and across lens models with different numbers of subhalos. Unlike traditional cataloging of subhalos, it does not require model subhalos to improve the goodness of fit above the detection threshold. Instead, it allows the exploitation of all information contained in the photon count maps—for instance, when constraining the subhalo mass function. We further show that, by not including these small subhalos in the lens model, fixed-dimensional inference methods can significantly mismodel the data. Using a simulated Hubble Space Telescope data set, we show that the subhalo mass function can be probed even when many subhalos in the sample catalogs are individually below the detection threshold and would be absent in a traditional catalog. The implemented software, Probabilistic Cataloger (PCAT) is made publicly available at https://github.com/tdaylan/pcat.
Risk assessment related to biogenic amines occurrence in ready-to-eat baby foods.
Czajkowska-Mysłek, Anna; Leszczyńska, Joanna
2017-07-01
Potential adverse reactions among infants and young children could appear after consumption of food containing small amounts of bioactive amines. This study presents the first assessment of biogenic amines occurrence in ready-to-eat vegetable without/with fish, meat and fruit baby products intended for the youngest consumers. The biogenic amine profiles and quantities of 6 amines were evaluated in 68 commercial baby foods produced by 10 leading manufacturers available in Poland, using HPLC-APCI-MS method. The total amine contents in analyzed products were obtained in the range of 1283-101421 ng/g. The maximum level of histamine (2375 ng/g) was found in the sample with spinach, tyramine (1667 ng/g) in fruit sample with banana, and of di- and polyamines (1263-53416 ng/g) in samples containing green peas. The results of amine analysis in baby foods indicated the presence of food ingredients which may be necessary to remove (tuna, possibly spinach) or reduce the amount added (spinach, green peas), either reduce their use by infants under 12 months of age (beef). Special attention should also be given to control the consumption of fruit baby products containing banana (higher tyramine and putrescine level). On the basis of obtained results a potential %ARfD, and the BAI were also evaluated. Copyright © 2017 Elsevier Ltd. All rights reserved.
Gupta, Dhrubajyoti; Ghosh, Rita; Mitra, Ajoy K; Roy, Subinit; Sarkar, Manoranjan; Chowdhury, Subhajit; Bhowmik, Asit; Mukhopadhyay, Ujjal; Maskey, Shila; Ro, Chul-Un
2011-11-01
The long-term environmental impact of municipal solid waste (MSW) landfilling is still under investigation due to the lack of detailed characterization studies. A MSW landfill site, popularly known as Dhapa, in the eastern fringe of the metropolis of Kolkata, India, is the subject of present study. A vast area of Dhapa, adjoining the current core MSW dump site and evolving from the raw MSW dumping in the past, is presently used for the cultivation of vegetables. The inorganic chemical characteristics of the MSW-contaminated Dhapa surface soil (covering a 2-km stretch of the area) along with a natural composite (geogenic) soil sample (from a small countryside farm), for comparison, were investigated using two complementary nondestructive analytical techniques, energy-dispersive X-ray fluorescence (EDXRF) for bulk analysis and low-Z (atomic number) particle electron probe X-ray microanalysis (low-Z particle EPMA) for single-particle analysis. The bulk concentrations of K, Rb, and Zr remain almost unchanged in all the soil samples. The Dhapa soil is found to be polluted with heavy metals such as Cu, Zn, and Pb (highly elevated) and Ti, Cr, Mn, Fe, Ni, and Sr (moderately elevated), compared to the natural countryside soil. These high bulk concentration levels of heavy metals were compared with the Ecological Soil Screening Levels for these elements (U.S. Environment Protection Agency) to assess the potential risk on the immediate biotic environment. Low-Z particle EPMA results showed that the aluminosilicate-containing particles were the most abundant, followed by SiO2, CaCO3-containing, and carbonaceous particles in the Dhapa samples, whereas in the countryside sample only aluminosilicate-containing and SiO2 particles were observed. The mineral particles encountered in the countryside sample are solely of geogenic origin, whereas those from the Dhapa samples seem to have evolved from a mixture of raw dumped MSW, urban dust, and other contributing factors such as wind, precipitation, weather patterns, farming, and water logging, resulting in their diverse chemical compositions and the abundant observation of carbonaceous species. Particles containing C and P were more abundant in the Dhapa samples than in the countryside soil sample, suggesting that MSW-contaminated soils are more fertile. However, the levels of particles containing potentially toxic heavy metals such as Cr, Mn, Ni, Cu, Zn, and/or Pb in the Dhapa samples were significant, corroborated by their high bulk concentration levels (EDXRF), causing deep concern for the immediate environment and contamination of the food chain through food crops.
Ostendorp, G
2015-04-01
In this study the drinking water of 212 small-scale water supplies, mainly situated in areas with intensive agriculture or fruit-growing, was analysed for uranium. The median uranium concentration amounted to 0.04 µg/lL, the 95(th) percentile was 2.5 µg/L. The maximum level was 14 µg/L. This sample exceeded the guideline value for uranium in drinking water. The uranium concentration in small-scale water supplies was found to be slightly higher than that in central water works in Schleswig-Holstein. Water containing more than 10 mg/L nitrate showed significantly higher uranium contents. The results indicate that the uranium burden in drinking water from small wells is mainly determined by geological factors. An additional anthropogenic effect of soil management cannot be excluded. Overall uranium concentrations were low and not causing health concerns. However, in specific cases higher concentrations may occur. © Georg Thieme Verlag KG Stuttgart · New York.
McDonald, G.D.; Paillet, Frederick L.; Barton, C.C.; Johnson, C.D.
1997-01-01
The clustering of orientations of hydraulically conductive fractures in bedrock at the Mirror Lake, New Hampshire fractured rock study site was investigated by comparing the orientations of fracture populations in two subvertical borehole arrays with those mapped on four adjacent subvertical roadcuts. In the boreholes and the roadcuts, the orientation of fracture populations appears very similar after borehole data are compensated for undersampling of steeply dipping fractures. Compensated borehole and pavement fracture data indicate a northeast-striking population of fractures with varying dips concentrated near that of the local foliation in the adjacent rock. The data show no correlation between fracture density (fractures/linear meter) and distance from lithologic contacts in both the boreholes and the roadcuts. The population of water-producing borehole fractures is too small (28 out of 610 fractures) to yield meaningful orientation comparisons. However, the orientation of large aperture fractures (which contains all the producing fractures) contains two or three subsidiary clusters in orientation frequency that are not evident in stereographic projections of the entire population containing all aperture sizes. Further, these subsidiary orientation clusters do not coincide with the dominant (subhorizontal and subvertical) regional fracture orientations.
Petrology and geochemistry of lithic fragments separated from the Apollo 15 deep-drill core
NASA Technical Reports Server (NTRS)
Lindstrom, M. M.; Nielsen, R. L.; Drake, M. J.
1977-01-01
Petrological and geochemical analysis of lithic fragments separated from the Apollo 15 deep-drill core showed these fragments to fall into the essentially the same range of rock types as observed in surface soil samples and large rock samples. Three particles are singled out as being of special interest. One sample is a mare basalt containing extremely evolved phases. The particle may represent small-scale imperfect crystal/liquid separation in a lava flow. A green glass particle is not the ultramafic emerald green glass described from the Apollo 15 site, but rather an ANT-like light green color, and has a quite different chemical composition from the ultramafic variety. One mare basalt displays a positive Eu anomaly and is enriched in plagioclase relative to olivine plus pyroxene.
Commeau, Judith A.; Valentine, Page C.
1991-01-01
Most of the sample analyzed by the method described were marine muds collected from the Gulf of Maine (Valentine and Commeau, 1990). The silt and clay fraction (up to 99 wt% of the sediment) is composed of clay minerals (chiefly illite-mica and chlorite), silt-size quartz and feldspar, and small crystals (2-12 um) of rutile and hematite. The bulk sediment samples contained an average of 2 to 3 wt percent CaCO3. Tiher samples analyzed include red and gray Carboniferous and Triassic sandstones and siltstones exposed around the Bay of Fundy region and Paleozoic sandstones, siltstones, and shales from northern Maine and New Brunswick. These rocks are probable sources for the fine-grained rutile found in the Gulf of Maine.
Chaffee, M.A.
1983-01-01
A technique called SCORESUM was developed to display a maximum of multi-element geochemical information on a minimum number of maps for mineral assessment purposes. The technique can be done manually for a small analytical data set or can be done with a computer for a large data set. SCORESUM can be used with highly censored data and can also weight samples so as to minimize the chemical differences of diverse lithologies in different parts of a given study area. The full range of reported analyses for each element of interest in a data set is divided into four categories. Anomaly scores - values of O (background), 1 (weakly anomalous), 2 (moderately anomalous), and 3 (strongly anomalous) - are substituted for all of the analyses falling into each of the four categories. A group of elements based on known or suspected association in altered or mineralized areas is selected for study and the anomaly scores for these elements are summed for each sample site and then plotted on a map. Some of the results of geochemical studies conducted for mineral assessments in two areas are briefly described. The first area, the Mokelumne Wilderness and vicinity, is a relatively small and geologically simple one. The second, the Walker Lake 1?? ?? 2?? quadrangle, is a large area that has extremely complex geology and that contains a number of different mineral deposit environments. These two studies provide examples of how the SCORESUM technique has been used (1) to enhance relatively small but anomalous areas and (2) to delineate and rank areas containing geochemical signatures for specific suites of elements related to certain types of alteration or mineralization. ?? 1983.
On the influence of crystal size and wavelength on native SAD phasing.
Liebschner, Dorothee; Yamada, Yusuke; Matsugaki, Naohiro; Senda, Miki; Senda, Toshiya
2016-06-01
Native SAD is an emerging phasing technique that uses the anomalous signal of native heavy atoms to obtain crystallographic phases. The method does not require specific sample preparation to add anomalous scatterers, as the light atoms contained in the native sample are used as marker atoms. The most abundant anomalous scatterer used for native SAD, which is present in almost all proteins, is sulfur. However, the absorption edge of sulfur is at low energy (2.472 keV = 5.016 Å), which makes it challenging to carry out native SAD phasing experiments as most synchrotron beamlines are optimized for shorter wavelength ranges where the anomalous signal of sulfur is weak; for longer wavelengths, which produce larger anomalous differences, the absorption of X-rays by the sample, solvent, loop and surrounding medium (e.g. air) increases tremendously. Therefore, a compromise has to be found between measuring strong anomalous signal and minimizing absorption. It was thus hypothesized that shorter wavelengths should be used for large crystals and longer wavelengths for small crystals, but no thorough experimental analyses have been reported to date. To study the influence of crystal size and wavelength, native SAD experiments were carried out at different wavelengths (1.9 and 2.7 Å with a helium cone; 3.0 and 3.3 Å with a helium chamber) using lysozyme and ferredoxin reductase crystals of various sizes. For the tested crystals, the results suggest that larger sample sizes do not have a detrimental effect on native SAD data and that long wavelengths give a clear advantage with small samples compared with short wavelengths. The resolution dependency of substructure determination was analyzed and showed that high-symmetry crystals with small unit cells require higher resolution for the successful placement of heavy atoms.
Zhou, Guisheng; Wang, Mengyue; Li, Yang; Peng, Ying; Li, Xiaobo
2015-08-01
In the present study, a new strategy based on chemical analysis and chemometrics methods was proposed for the comprehensive analysis and profiling of underivatized free amino acids (FAAs) and small peptides among various Luo-Han-Guo (LHG) samples. Firstly, the ultrasound-assisted extraction (UAE) parameters were optimized using Plackett-Burman (PB) screening and Box-Behnken designs (BBD), and the following optimal UAE conditions were obtained: ultrasound power of 280 W, extraction time of 43 min, and the solid-liquid ratio of 302 mL/g. Secondly, a rapid and sensitive analytical method was developed for simultaneous quantification of 24 FAAs and 3 active small peptides in LHG at trace levels using hydrophilic interaction ultra-performance liquid chromatography coupled with triple-quadrupole linear ion-trap tandem mass spectrometry (HILIC-UHPLC-QTRAP(®)/MS(2)). The analytical method was validated by matrix effects, linearity, LODs, LOQs, precision, repeatability, stability, and recovery. Thirdly, the proposed optimal UAE conditions and analytical methods were applied to measurement of LHG samples. It was shown that LHG was rich in essential amino acids, which were beneficial nutrient substances for human health. Finally, based on the contents of the 27 analytes, the chemometrics methods of unsupervised principal component analysis (PCA) and supervised counter propagation artificial neural network (CP-ANN) were applied to differentiate and classify the 40 batches of LHG samples from different cultivated forms, regions, and varieties. As a result, these samples were mainly clustered into three clusters, which illustrated the cultivating disparity among the samples. In summary, the presented strategy had potential for the investigation of edible plants and agricultural products containing FAAs and small peptides.
A comparison of moment-based methods of estimation for the log Pearson type 3 distribution
NASA Astrophysics Data System (ADS)
Koutrouvelis, I. A.; Canavos, G. C.
2000-06-01
The log Pearson type 3 distribution is a very important model in statistical hydrology, especially for modeling annual flood series. In this paper we compare the various methods based on moments for estimating quantiles of this distribution. Besides the methods of direct and mixed moments which were found most successful in previous studies and the well-known indirect method of moments, we develop generalized direct moments and generalized mixed moments methods and a new method of adaptive mixed moments. The last method chooses the orders of two moments for the original observations by utilizing information contained in the sample itself. The results of Monte Carlo experiments demonstrated the superiority of this method in estimating flood events of high return periods when a large sample is available and in estimating flood events of low return periods regardless of the sample size. In addition, a comparison of simulation and asymptotic results shows that the adaptive method may be used for the construction of meaningful confidence intervals for design events based on the asymptotic theory even with small samples. The simulation results also point to the specific members of the class of generalized moments estimates which maintain small values for bias and/or mean square error.
NASA Astrophysics Data System (ADS)
Kim, Byeong-Keun; Akram, Kashif; Kim, Cheong-Tae; Kang, Na-Roo; Lee, Jin-Won; Ryang, Jun-Hwan; Kwon, Joong-Ho
2012-08-01
For the identification of irradiated food, current analysis methods have limitations regarding presence and stability of radiation-induced markers. In this study, different spice blends with small quantity of different irradiated (0, 1 and 10 kGy) spice powders, such as red pepper, garlic or ginger, were investigated using PSL and TL techniques. In PSL-based screening analysis, the spice blends containing 10% of irradiated materials (1 or 10 kGy) were determined as intermediate or positive. In TL results, the blends containing 1% of 1 or 10 kGy-irradiated spices showed the typical TL glow curves that could be interpreted as positive. The blends with irradiated garlic powder provided more good results where identification was possible at 0.5% mixing of irradiated sample. However, the TL ratios of all spice blends were <0.1 and only TL glow curve shape and intensity may be used to discriminate the samples having irradiated component.
Occurrences of uranium at Clinton, Hunterdon County, New Jersey
McKeown, F.A.; Klemic, H.; Choquette, P.W.
1954-01-01
An occurrence of uranium at Clinton, Hunterdon County, N. J. was first brought to the attention of the U.S. Geological Survey when Mr. Thomas L. Eak of Avenel, N. J. submitted to the Survey a sample containing 0.068 percent uranium. Subsequent examinations of the area around Clinton indicated that detailed mapping and study were warranted. The uranium occurrences at Clinton are in or associated with fault zones in the Kittatinny limestone of Cambro-Ordovician age. The limestone generally light gray, thick bedded, and dolomitic; chert is common but not abundant. Regionally and locally, faults are the most significant structural features. The local faults at Clinton are the loci for most of the uranium. The largest fault can be traced for about 700 feet and is radioactive everywhere it crops out. Samples from this fault contain as much as 0.038 percent uranium; the average content is about 0.010 percent uranium. Uranium also occurs disseminated in two 4-inch layers of black feldspathic dolomite and in several zones of residual soil derived from the Kittatinny limestone. The black layers contain as much as 0.046 percent uranium and can be traced only about 20 feet along strike. They are cut by a small fault that is also radioactive. The radioactive soil zones are roughly elongated parallel to bedding. Soil from them contains up to 0.008 percent uranium. The uranium occurrences are best explained by a supergene origin. The sampling, mapping, and radioactivity testing of uranium occurrences at Clinton indicate they are too low grade to be of current economic interest.
Ultrasonic characterization of single drops of liquids
Sinha, D.N.
1998-04-14
Ultrasonic characterization of single drops of liquids is disclosed. The present invention includes the use of two closely spaced transducers, or one transducer and a closely spaced reflector plate, to form an interferometer suitable for ultrasonic characterization of droplet-size and smaller samples without the need for a container. The droplet is held between the interferometer elements, whose distance apart may be adjusted, by surface tension. The surfaces of the interferometer elements may be readily cleansed by a stream of solvent followed by purified air when it is desired to change samples. A single drop of liquid is sufficient for high-quality measurement. Examples of samples which may be investigated using the apparatus and method of the present invention include biological specimens (tear drops; blood and other body fluid samples; samples from tumors, tissues, and organs; secretions from tissues and organs; snake and bee venom, etc.) for diagnostic evaluation, samples in forensic investigations, and detection of drugs in small quantities. 5 figs.
Ultrasonic characterization of single drops of liquids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sinha, D.N.
Ultrasonic characterization of single drops of liquids is disclosed. The present invention includes the use of two closely spaced transducers, or one transducer and a closely spaced reflector plate, to form an interferometer suitable for ultrasonic characterization of droplet-size and smaller samples without the need for a container. The droplet is held between the interferometer elements, whose distance apart may be adjusted, by surface tension. The surfaces of the interferometer elements may be readily cleansed by a stream of solvent followed by purified air when it is desired to change samples. A single drop of liquid is sufficient for high-qualitymore » measurement. Examples of samples which may be investigated using the apparatus and method of the present invention include biological specimens (tear drops; blood and other body fluid samples; samples from tumors, tissues, and organs; secretions from tissues and organs; snake and bee venom, etc.) for diagnostic evaluation, samples in forensic investigations, and detection of drugs in small quantities. 5 figs.« less
Studying Ultradisperse Diamond Structure within Explosively Synthesized Samples via X-Ray Techniques
NASA Astrophysics Data System (ADS)
Sharkov, M. D.; Boiko, M. E.; Ivashevskaya, S. N.; Belyakova, N. S.
2013-08-01
XRD (X-Ray Diffraction) and SAXS (Small-Angle X-Ray Scattering) data have been measured for a pair of samples produced with the help of explosives. XRD peaks have shown the both samples to contain crystal diamond components as well as graphite ones. Basing on SAXS analysis, possible presence of grains with radii up to 30-50 nm within all the samples has been shown. Structure components with fractal dimension between 1 and 2 in the sample have been detected, this fact being in agreement with the assumption of diamond grain coating similarity to onion shells. In order to broad rocking curves analysis, the standard SAXS treatment technique has been complemented by a Fourier filtering procedure. For the sample #1, rocking curve components corresponding to individual interplanar distances with magnitudes from 5 nm up to 15 nm have been separated. A hypothesis relating these values to the distances between concentric onion-like shells of diamond grains has been formulated.
Morgan, Sue
2009-07-01
One of the well-known needs of teenagers and young adults with cancer (TYAs) is their quest for knowledge about their illness and its treatment. As well as this they desire to be treated as partners and as an integral part of the team who care for them. This small exploratory study aims to address these issues in the development of a unique project where the young people were given unprecedented access to their own cancer samples and to the professional experts who analyse those samples. This small cohort of 31 TYAs, aged 13-24 years, were invited to look at their samples under a microscope and discuss it with the experts; of these 4 declined. A number of questionnaires, containing both open and closed questions, were given before, immediately post and one month after the viewing session. The results were analysed using SPSS13 and content analysis. The study was able to establish that viewing cancer samples had no measurable effect on the TYAs gaining of new knowledge, sense of control or choices that they made. However, it did show how the young people felt in light of actually 'seeing' their own cancer, and how this seemed to improve the overall perception of their disease. This is a new body of knowledge that requires further, more detailed, rigorous work.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reubi, J.C.; Torhorst, J.
1989-09-15
The somatostatin (SS) and the epidermal growth factor (EGF) receptor content have been established in 36 primary breast cancers by receptor autoradiography on adjacent tissue sections. Iodine 125 (125I)-EGF was used as radioligand for EGF receptor visualization whereas an iodinated SS-28 analogue or an octapeptide SS analogue were used to measure SS receptors. Six of 36 tumors contained SS receptors, whereas ten of the 36 tumors were shown to contain EGF receptors. None of the tumor samples containing SS receptors were simultaneously EGF receptor positive. In contrast, all SS receptor-positive tumors simultaneously contained steroid receptors. The positive correlation between SSmore » receptors and steroid receptors as well as the negative correlation between SS receptors and EGF receptors therefore suggest that the small percentage of SS receptor-positive breast tumors are a group of differentiated breast tumors with a good prognosis. In these cases, combined hormonetherapy including SS analogs may be of potential interest.« less
Automatic extraction and processing of small RNAs on a multi-well/multi-channel (M&M) chip.
Zhong, Runtao; Flack, Kenneth; Zhong, Wenwan
2012-12-07
The study of the regulatory roles in small RNAs can be accelerated by techniques that permit simple, low-cost, and rapid extraction of small RNAs from a small number of cells. In order to ensure highly specific and sensitive detection, the extracted RNAs should be free of the background nucleic acids and present stably in a small volume. To meet these criteria, we designed a multi-well/multi-channel (M&M) chip to carry out automatic and selective isolation of small RNAs via solid-phase extraction (SPE), followed by reverse-transcription (RT) to convert them to the more stable cDNAs in a final volume of 2 μL. Droplets containing buffers for RNA binding, washing, and elution were trapped in microwells, which were connected by one channel, and suspended in mineral oil. The silica magnetic particles (SMPs) for SPE were moved along the channel from well to well, i.e. in between droplets, by a fixed magnet and a translation stage, allowing the nucleic acid fragments to bind to the SMPs, be washed, and then be eluted for RT reaction within 15 minutes. RNAs shorter than 63 nt were selectively enriched from cell lysates, with recovery comparable to that of a commercial kit. Physical separation of the droplets on our M&M chip allowed the usage of multiple channels for parallel processing of multiple samples. It also permitted smooth integration with on-chip RT-PCR, which simultaneously detected the target microRNA, mir-191, expressed in fewer than 10 cancer cells. Our results have demonstrated that the M&M chip device is a valuable and cost-saving platform for studying small RNA expression patterns in a limited number of cells with reasonable sample throughput.
Niwa, O; Horiuchi, T; Torimitsu, K
1997-01-01
A small volume L-glutamate online sensor was developed in order to monitor changes in the local concentration of L-glutamate released from cultured nerve cells. Syringe pump in the suction mode is used to sample extracellular fluid continuously from a glass micro-capillary and the concentration of L-glutamate can be determined by using a glassy carbon (GC) electrode modified with an Os-polyvinylpyridine mediator bottom film containing horseradish peroxidase and a bovine serum albumin top layer containing L-glutamate oxidase. The overall efficiency of L-glutamate detection with a sensor is 71% under optimum conditions due to an efficient enzymatic reaction at the modified electrode in the thin layer radial flow cell. As a result, we achieved a detection limit of 7-15 nM and a linear range of 50 nM to 10 microM. In an in vitro experiment, the extracellular fluid near a particular nerve cell can be sampled with this micro-pipet and continuously introduced into the modified GC electrode in the radial flow cell via suction provided by a syringe pump. The nerve cells are stimulated by the KCl in a glass capillary and the L-glutamate concentration change can be monitored by changing the distance between the sampling pipet and the nerve cells.
Characteristics of formed Atlantic salmon jerky.
Oberholtzer, Ashlan S; Dougherty, Michael P; Camire, Mary Ellen
2011-08-01
Smoked salmon (Salmo salar L.) processing may generate large amounts of small pieces of trimmed flesh that has little economic value. Opportunities exist to develop new added-value foods from this by-product. Brining was compared with dry salting for the production of formed salmon jerky-style strips that were then smoked. The formulations also contained brown sugar and potato starch. Salted samples had higher salt concentrations and required less force to break using a TA-XT2 Texture Analyzer. Brined samples contained more fat and were darker, redder and more yellow than the salted samples. Processing concentrated omega-3 fatty acids compared with raw salmon, and the brined jerky had the highest omega-3 fatty acid content. A panel of 57 consumers liked the appearance and aroma of both samples equally (approximately 6.7 for appearance and 6.3 for aroma on the 9-point hedonic scale. Higher acceptability scores for taste, texture, and overall quality were given to the brined product (6.7 to 6.9 against 6.2 to 6.3). Salmon trim from smoking facilities can be utilized to produce a jerky that is a good source of omega-3 fatty acids, simultaneously adding value and reducing the waste stream. © 2011 Institute of Food Technologists®
Lu, Xujin; Lloyd, David K; Klohr, Steven E
2016-01-01
A feasibility study was conducted for a sensitive and robust dye immersion method for the measurement of container closure integrity of unopened prefilled syringes using fluorescence spectrophotometry as the detection method. A Varian Cary Eclipse spectrofluorometer was used with a custom-made sample holder to position the intact syringe in the sample compartment for fluorescence measurements. Methylene blue solution was initially evaluated as the fluorophore in a syringe with excitation at 607 nm and emission at 682 nm, which generated a limit of detection of 0.05 μg/mL. Further studies were conducted using rhodamine 123, a dye with stronger fluorescence. Using 480 nm excitation and 525 nm emission, the dye in the syringe could be easily detected at levels as low as 0.001 μg/mL. The relative standard deviation for 10 measurements of a sample of 0.005 μg/mL (with repositioning of the syringe after each measurement) was less than 1.1%. A number of operational parameters were optimized, including the photomultiplier tube voltage, excitation, and emission slit widths. The specificity of the testing was challenged by using marketed drug products and a protein sample, which showed no interference to the rhodamine detection. Results obtained from this study demonstrated that using rhodamine 123 for container closure integrity testing with in-situ (in-syringe) fluorescence measurements significantly enhanced the sensitivity and robustness of the testing and effectively overcame limitations of the traditional methylene blue method with visual or UV-visible absorption detection. Ensuring container closure integrity of injectable pharmaceutical products is necessary to maintain quality throughout the shelf life of a sterile drug product. Container closure integrity testing has routinely been used to evaluate closure integrity during product development and production line qualification of prefilled syringes, vials, and devices. However, container closure integrity testing has recently gained industry attention due to increased regulatory agency scrutiny regarding the analytical rigor of container closure integrity testing methods and expectations to use container closure integrity testing in lieu of sterility tests in stability programs. Methylene blue dye is often used for dye ingress testing of container closure integrity, but we found it unsuitable for reliable detection of small breaches in prefilled syringes of drug product. This work describes the suitability and advantages of using a fluorescent dye and spectroscopic detection for a robust, sensitive, and quality control-friendly container closure integrity testing method for prefilled syringes. © PDA, Inc. 2016.
He, Wenhan; Wu, Qin; Livshits, Maksim Y.; ...
2016-05-23
A novel Pt-bisacetylide small molecule (Pt-SM) featuring “roller-wheel” geometry was synthesized and characterized. When compared with conventional Pt-containing polymers and small molecules having “dumbbell” shaped structures, Pt-SM displays enhanced crystallinity and intermolecular π–π interactions, as well as favorable panchromatic absorption behaviors. Furthermore, organic solar cells (OSCs) employing Pt-SM achieve power conversion efficiencies (PCEs) up to 5.9%, the highest reported so far for Pt-containing polymers and small molecules.
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, Wenhan; Wu, Qin; Livshits, Maksim Y.
A novel Pt-bisacetylide small molecule (Pt-SM) featuring “roller-wheel” geometry was synthesized and characterized. When compared with conventional Pt-containing polymers and small molecules having “dumbbell” shaped structures, Pt-SM displays enhanced crystallinity and intermolecular π–π interactions, as well as favorable panchromatic absorption behaviors. Furthermore, organic solar cells (OSCs) employing Pt-SM achieve power conversion efficiencies (PCEs) up to 5.9%, the highest reported so far for Pt-containing polymers and small molecules.
Poole, Angela C.; Pischel, Lauren; Ley, Catherine; Suh, Gina; Goodrich, Julia K.; Haggerty, Thomas D.; Ley, Ruth E.
2016-01-01
ABSTRACT Commonly prescribed antibiotics are known to alter human microbiota. We hypothesized that triclosan and triclocarban, components of many household and personal care products (HPCPs), may alter the oral and gut microbiota, with potential consequences for metabolic function and weight. In a double-blind, randomized, crossover study, participants were given triclosan- and triclocarban (TCS)-containing or non-triclosan/triclocarban (nTCS)-containing HPCPs for 4 months and then switched to the other products for an additional 4 months. Blood, stool, gingival plaque, and urine samples and weight data were obtained at baseline and at regular intervals throughout the study period. Blood samples were analyzed for metabolic and endocrine markers and urine samples for triclosan. The microbiome in stool and oral samples was then analyzed. Although there was a significant difference in the amount of triclosan in the urine between the TCS and nTCS phases, no differences were found in microbiome composition, metabolic or endocrine markers, or weight. Though this study was limited by the small sample size and imprecise administration of HPCPs, triclosan at physiologic levels from exposure to HPCPs does not appear to have a significant or important impact on human oral or gut microbiome structure or on a panel of metabolic markers. IMPORTANCE Triclosan and triclocarban are commonly used commercial microbicides found in toothpastes and soaps. It is unknown what effects these chemicals have on the human microbiome or on endocrine function. From this randomized crossover study, it appears that routine personal care use of triclosan and triclocarban neither exerts a major influence on microbial communities in the gut and mouth nor alters markers of endocrine function in humans. PMID:27303746
NASA Astrophysics Data System (ADS)
Tamamitsu, Miu; Zhang, Yibo; Wang, Hongda; Wu, Yichen; Ozcan, Aydogan
2018-02-01
The Sparsity of the Gradient (SoG) is a robust autofocusing criterion for holography, where the gradient modulus of the complex refocused hologram is calculated, on which a sparsity metric is applied. Here, we compare two different choices of sparsity metrics used in SoG, specifically, the Gini index (GI) and the Tamura coefficient (TC), for holographic autofocusing on dense/connected or sparse samples. We provide a theoretical analysis predicting that for uniformly distributed image data, TC and GI exhibit similar behavior, while for naturally sparse images containing few high-valued signal entries and many low-valued noisy background pixels, TC is more sensitive to distribution changes in the signal and more resistive to background noise. These predictions are also confirmed by experimental results using SoG-based holographic autofocusing on dense and connected samples (such as stained breast tissue sections) as well as highly sparse samples (such as isolated Giardia lamblia cysts). Through these experiments, we found that ToG and GoG offer almost identical autofocusing performance on dense and connected samples, whereas for naturally sparse samples, GoG should be calculated on a relatively small region of interest (ROI) closely surrounding the object, while ToG offers more flexibility in choosing a larger ROI containing more background pixels.
Hopkins, Max; Kailasan, Shweta; Cohen, Allison; Roux, Simon; Tucker, Kimberly Pause; Shevenell, Amelia; Agbandje-McKenna, Mavis; Breitbart, Mya
2014-01-01
The small single-stranded DNA (ssDNA) bacteriophages of the subfamily Gokushovirinae were traditionally perceived as narrowly targeted, niche-specific viruses infecting obligate parasitic bacteria, such as Chlamydia. The advent of metagenomics revealed gokushoviruses to be widespread in global environmental samples. This study expands knowledge of gokushovirus diversity in the environment by developing a degenerate PCR assay to amplify a portion of the major capsid protein (MCP) gene of gokushoviruses. Over 500 amplicons were sequenced from 10 environmental samples (sediments, sewage, seawater and freshwater), revealing the ubiquity and high diversity of this understudied phage group. Residue-level conservation data generated from multiple alignments was combined with a predicted 3D structure, revealing a tendency for structurally internal residues to be more highly conserved than surface-presenting protein–protein or viral–host interaction domains. Aggregating this data set into a phylogenetic framework, many gokushovirus MCP clades contained samples from multiple environments, although distinct clades dominated the different samples. Antarctic sediment samples contained the most diverse gokushovirus communities, whereas freshwater springs from Florida were the least diverse. Whether the observed diversity is being driven by environmental factors or host-binding interactions remains an open question. The high environmental diversity of this previously overlooked ssDNA viral group necessitates further research elucidating their natural hosts and exploring their ecological roles. PMID:24694711
Herrick, Robert F; Stewart, James H; Allen, Joseph G
2016-02-01
PCBs in building materials such as caulks and sealants are a largely unrecognized source of contamination in the building environment. Schools are of particular interest, as the period of extensive school construction (about 1950 to 1980) coincides with the time of greatest use of PCBs as plasticizers in building materials. In the USA, we estimate that the number of schools with PCB in building caulk ranges from 12,960 to 25,920 based upon the number of schools built in the time of PCB use and the proportion of buildings found to contain PCB caulk and sealants. Field and laboratory studies have demonstrated that PCBs from both interior and exterior caulking can be the source of elevated PCB air concentrations in these buildings, at levels that exceed health-based PCB exposure guidelines for building occupants. Air sampling in buildings containing PCB caulk has shown that the airborne PCB concentrations can be highly variable, even in repeat samples collected within a room. Sampling and data analysis strategies that recognize this variability can provide the basis for informed decision making about compliance with health-based exposure limits, even in cases where small numbers of samples are taken. The health risks posed by PCB exposures, particularly among children, mandate precautionary approaches to managing PCBs in building materials.
Study of the atmospheric aerosol composition in equatorial Africa using PIXE as analytical technique
NASA Astrophysics Data System (ADS)
Maenhaut, W.; Akilimali, K.
1987-03-01
Small Nuclepore total filter holders and a single orifice 8-stage cascade impactor were used to collect atmospheric aerosol samples in Kinshasa, Zaire, and Butare, Rwanda. The samples were analyzed for about 20 elements by means of the PIXE technique. The results obtained for parallel samples, taken with two total filter holders and one cascade impactor, were generally in excellent agreement, suggesting that the different samplers collected very similar aerosol particle populations. Most elements were associated with a crustal dust dispersion source, which may include road dust dispersal. The Butare samples, particularly those collected during the night, were significantly influenced by biomass burning, as was deduced from enhanced filter blackness and noncrustal K levels. The pyrogenic component also contained P, S, Mn and Rb. Br and Pb were highly enriched at both locations, indicating that automotive sources had a strong influence on the aerosol composition.
Foam generation and sample composition optimization for the FOAM-C experiment of the ISS
NASA Astrophysics Data System (ADS)
Carpy, R.; Picker, G.; Amann, B.; Ranebo, H.; Vincent-Bonnieu, S.; Minster, O.; Winter, J.; Dettmann, J.; Castiglione, L.; Höhler, R.; Langevin, D.
2011-12-01
End of 2009 and early 2010 a sealed cell, for foam generation and observation, has been designed and manufactured at Astrium Friedrichshafen facilities. With the use of this cell, different sample compositions of "wet foams" have been optimized for mixtures of chemicals such as water, dodecanol, pluronic, aethoxisclerol, glycerol, CTAB, SDS, as well as glass beads. This development is performed in the frame of the breadboarding development activities of the Experiment Container FOAM-C for operation in the ISS Fluid Science Laboratory (ISS). The sample cell supports multiple observation methods such as: Diffusing-Wave and Diffuse Transmission Spectrometry, Time Resolved Correlation Spectroscopy [1] and microscope observation, all of these methods are applied in the cell with a relatively small experiment volume <3cm3. These units, will be on orbit replaceable sets, that will allow multiple sample compositions processing (in the range of >40).
Microbial diversity and community structure in an antimony-rich tailings dump.
Xiao, Enzong; Krumins, Valdis; Dong, Yiran; Xiao, Tangfu; Ning, Zengping; Xiao, Qingxiang; Sun, Weimin
2016-09-01
To assess the impact of antimony (Sb) on microbial community structure, 12 samples were taken from an Sb tailings pile in Guizhou Province, Southwest China. All 12 samples exhibited elevated Sb concentrations, but the mobile and bioaccessible fractions were small in comparison to total Sb concentrations. Besides the geochemical analyses, microbial communities inhabiting the tailing samples were characterized to investigate the interplay between the microorganisms and environmental factors in mine tailings. In all samples, Proteobacteria and Actinobacteria were the most dominant phyla. At the genus level, Thiobacillus, Limnobacter, Nocardioides, Lysobacter, Phormidium, and Kaistobacter demonstrated relatively high abundances. The two most abundant genera, Thiobacillus and Limnobacter, are characterized as sulfur-oxidizing bacteria and thiosulfate-oxidizing bacteria, respectively, while the genus Lysobacter contains arsenic (As)-resistant bacteria. Canonical correspondence analysis (CCA) indicates that TOC and the sulfate to sulfide ratio strongly shaped the microbial communities, suggesting the influence of the environmental factors in the indigenous microbial communities.
Evaluation of complex gonioapparent samples using a bidirectional spectrometer.
Rogelj, Nina; Penttinen, Niko; Gunde, Marta Klanjšek
2015-08-24
Many applications use gonioapparent targets whose appearance depends on irradiation and viewing angles; the strongest effects are provided by light diffraction. These targets, optically variable devices (OVDs), are used in both security and authentication applications. This study introduces a bidirectional spectrometer, which enables to analyze samples with most complex angular and spectral properties. In our work, the spectrometer is evaluated with samples having very different types of reflection, concerning spectral and angular distributions. Furthermore, an OVD containing several different grating patches is evaluated. The device uses automatically adjusting exposure time to provide maximum signal dynamics and is capable of doing steps as small as 0.01°. However, even 2° steps for the detector movement showed that this device is more than capable of characterizing even the most complex reflecting surfaces. This study presents sRGB visualizations, discussion of bidirectional reflection, and accurate grating period calculations for all of the grating samples used.
Volcanic Ash fall Impact on Vegetation, Colima 2005
NASA Astrophysics Data System (ADS)
Garcia, M. G.; Martin, A.; Fonseca, R.; Nieto, A.; Radillo, R.; Armienta, M.
2007-05-01
An ash sampling network was established arround Colima Volcano in 2005. Ash fall was sampled on the North, Northeast, East, Southeast, South, Southwest and West of the volcano. Samples were analyzed for ash components, geochemistry and leachates. Ash fall ocurred on April (12), May (10, 23), June (2, 6, 9, 10, 12, 14), July (27), September (27), October (23) and November (24). Most of the ash is made of andesitic dome-lithics but shows diferences in crystal, juvenile material and lithic content. In May, some samples contained grey and dark pumice (scoria). Texture varies from phi >4 to phi 0. Leachate concentration were low: SO4 (7.33-54.19) Cl- (2.29-4.97) and F- (0.16-0.37). During 2005, Colima Volcano's ash fall rotted some of the guava and peach fruits and had a drying effect on spearment and epazote plants. Even these small ash amounts could have hindered sugar cane and agave growth.
Sample introduction apparatus for a flow cytometer
Van den Engh, Ger
1998-01-01
A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning HPLC tubing and fittings may be used in a manner which facilitates removable of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it.
Sample introduction system for a flow cytometer
Van den Engh, Ger
1997-01-01
A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning, HPLC tubing and fittings may be used in a manner which facilitates removing of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it.
Sample introduction apparatus for a flow cytometer
Van den Engh, G.
1998-03-10
A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning HPLC tubing and fittings may be used in a manner which facilitates removable of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it. 3 figs.
Sample introduction system for a flow cytometer
Engh, G. van den
1997-02-11
A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning, HPLC tubing and fittings may be used in a manner which facilitates removing of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it. 3 figs.
Re-electrospraying splash-landed proteins and nanoparticles.
Benner, W Henry; Lewis, Gregory S; Hering, Susanne V; Selgelke, Brent; Corzett, Michelle; Evans, James E; Lightstone, Felice C
2012-03-06
FITC-albumin, Lsr-F, or fluorescent polystyrene latex particles were electrosprayed from aqueous buffer and subjected to dispersion by differential electrical mobility at atmospheric pressure. A resulting narrow size cut of singly charged molecular ions or particles was passed through a condensation growth tube collector to create a flow stream of small water droplets, each carrying a single ion or particle. The droplets were splash landed (impacted) onto a solid or liquid temperature controlled surface. Small pools of droplets containing size-selected particles, FITC-albumin, or Lsr-F were recovered, re-electrosprayed, and, when analyzed a second time by differential electrical mobility, showed increased homogeneity. Transmission electron microscopy (TEM) analysis of the size-selected Lsr-F sample corroborated the mobility observation.
Buňková, Leona; Adamcová, Gabriela; Hudcová, Kateřina; Velichová, Helena; Pachlová, Vendula; Lorencová, Eva; Buňka, František
2013-11-01
The aim of the study was the monitoring of six biogenic amines (histamine, tyramine, phenylethylamine, tryptamine, putrescine, and cadaverine) and two polyamines (spermidine and spermine) in 112 samples of dairy products purchased in the Czech Republic, namely in 55 cheeses made in small-scale farms and in 57 fermented dairy products. The products were tested at the end of their shelf-life period. Neither tryptamine nor phenylethylamine was detected in the monitored samples; histamine was found only in four cheese samples containing up to 25mg/kg. The contents of spermine and spermidine were low and did not exceed the values of 35 mg/kg. Significant amounts of tyramine, putrescine, and cadaverine occurred especially in cheeses produced from ewe's milk or in long-term ripened cheeses. In about 10% of the tested cheeses, the total concentration of all the monitored biogenic amines and polyamines exceeded the level of 200mg/kg, which can be considered toxicologically significant. In fermented dairy products, the tested biogenic amines occurred in relatively low amounts (generally up to 30 mg/kg) that are regarded safe for the consumer's health. Copyright © 2013 Elsevier Ltd. All rights reserved.
The viking biological investigation: preliminary results.
Klein, H P; Horowitz, N H; Levin, G V; Oyama, V I; Lederberg, J; Rich, A; Hubbard, J S; Hobby, G L; Straat, P A; Berdahl, B J; Carle, G C; Brown, F S; Johnson, R D
1976-10-01
Three different types of biological experiments on samples of martian surface material ("soil") were conducted inside the Viking lander. In the carbon assimilation or pyrolytic release experiment, (14)CO(2) and (14)CO were exposed to soil in the presence of light. A small amount of gas was found to be converted into organic material. Heat treatment of a duplicate sample prevented such conversion. In the gas exchange experiment, soil was first humidified (exposed to water vapor) for 6 sols and then wet with a complex aqueous solution of metabolites. The gas above the soil was monitored by gas chromatography. A substantial amount of O(2) was detected in the first chromatogram taken 2.8 hours after humidification. Subsequent analyses revealed that significant increases in CO(2) and only small changes in N(2) had also occurred. In the labeled release experiment, soil was moistened with a solution containing several (14)C-labeled organic compounds. A substantial evolution of radioactive gas was registered but did not occur with a duplicate heat-treated sample. Alternative chemical and biological interpretations are possible for these preliminary data. The experiments are still in process, and these results so far do not allow a decision regarding the existence of life on the plonet Mars.
Seven common mistakes in population genetics and how to avoid them.
Meirmans, Patrick G
2015-07-01
As the data resulting from modern genotyping tools are astoundingly complex, genotyping studies require great care in the sampling design, genotyping, data analysis and interpretation. Such care is necessary because, with data sets containing thousands of loci, small biases can easily become strongly significant patterns. Such biases may already be present in routine tasks that are present in almost every genotyping study. Here, I discuss seven common mistakes that can be frequently encountered in the genotyping literature: (i) giving more attention to genotyping than to sampling, (ii) failing to perform or report experimental randomization in the laboratory, (iii) equating geopolitical borders with biological borders, (iv) testing significance of clustering output, (v) misinterpreting Mantel's r statistic, (vi) only interpreting a single value of k and (vii) forgetting that only a small portion of the genome will be associated with climate. For every of those issues, I give some suggestions how to avoid the mistake. Overall, I argue that genotyping studies would benefit from establishing a more rigorous experimental design, involving proper sampling design, randomization and better distinction of a priori hypotheses and exploratory analyses. © 2015 John Wiley & Sons Ltd.
Tangchaikeeree, Tienrat; Polpanich, Duangporn; Elaissari, Abdelhamid; Jangpatarapongsa, Kulachart
2017-10-01
Colloidal magnetic particles (MPs) have been developed in association with molecular diagnosis for several decades. MPs have the great advantage of easy manipulation using a magnet. In nucleic acid detection, these particles can act as a capture support for rapid and simple biomolecule separation. The surfaces of MPs can be modified by coating with various polymer materials to provide functionalization for different applications. The use of MPs enhances the sensitivity and specificity of detection due to the specific activity on the surface of the particles. Practical applications of MPs demonstrate greater efficiency than conventional methods. Beyond traditional detection, MPs have been successfully adopted as a smart carrier in microfluidic and lab-on-a-chip biosensors. The versatility of MPs has enabled their integration into small single detection units. MPs-based biosensors can facilitate rapid and highly sensitive detection of very small amounts of a sample. In this review, the application of MPs to the detection of nucleic acids, from sample preparation to analytical readout systems, is described. State-of-the-art integrated microsystems containing microfluidic and lab-on-a-chip biosensors for the nucleic acid detection are also addressed. Copyright © 2017 Elsevier B.V. All rights reserved.
Apparatus and process for microbial detection and enumeration
NASA Technical Reports Server (NTRS)
Wilkins, J. R.; Grana, D. (Inventor)
1982-01-01
An apparatus and process for detecting and enumerating specific microorganisms from large volume samples containing small numbers of the microorganisms is presented. The large volume samples are filtered through a membrane filter to concentrate the microorganisms. The filter is positioned between two absorbent pads and previously moistened with a growth medium for the microorganisms. A pair of electrodes are disposed against the filter and the pad electrode filter assembly is retained within a petri dish by retainer ring. The cover is positioned on base of petri dish and sealed at the edges by a parafilm seal prior to being electrically connected via connectors to a strip chart recorder for detecting and enumerating the microorganisms collected on filter.
NASA Astrophysics Data System (ADS)
Astashev, M. E.; Belosludtsev, K. N.; Kharakoz, D. P.
2014-05-01
One of the most accurate methods for measuring the compressibility of liquids is resonance measurement of sound velocity in a fixed-length interferometer. This method combines high sensitivity, accuracy, and small sample volume of the test liquid. The measuring principle is to study the resonance properties of a composite resonator that contains a test liquid sample. Ealier, the phase-locked loop (PLL) scheme was used for this. In this paper, we propose an alternative measurement scheme based on digital analysis of harmonic signals, describe the implementation of this scheme using commercially available data acquisition modules, and give examples of test measurements with accuracy evaluations of the results.
NASA Astrophysics Data System (ADS)
Alexander, Louise; Snape, Joshua F.; Joy, Katherine H.; Downes, Hilary; Crawford, Ian A.
2016-09-01
Lunar mare basalts provide insights into the compositional diversity of the Moon's interior. Basalt fragments from the lunar regolith can potentially sample lava flows from regions of the Moon not previously visited, thus, increasing our understanding of lunar geological evolution. As part of a study of basaltic diversity at the Apollo 12 landing site, detailed petrological and geochemical data are provided here for 13 basaltic chips. In addition to bulk chemistry, we have analyzed the major, minor, and trace element chemistry of mineral phases which highlight differences between basalt groups. Where samples contain olivine, the equilibrium parent melt magnesium number (Mg#; atomic Mg/[Mg + Fe]) can be calculated to estimate parent melt composition. Ilmenite and plagioclase chemistry can also determine differences between basalt groups. We conclude that samples of approximately 1-2 mm in size can be categorized provided that appropriate mineral phases (olivine, plagioclase, and ilmenite) are present. Where samples are fine-grained (grain size <0.3 mm), a "paired samples t-test" can provide a statistical comparison between a particular sample and known lunar basalts. Of the fragments analyzed here, three are found to belong to each of the previously identified olivine and ilmenite basalt suites, four to the pigeonite basalt suite, one is an olivine cumulate, and two could not be categorized because of their coarse grain sizes and lack of appropriate mineral phases. Our approach introduces methods that can be used to investigate small sample sizes (i.e., fines) from future sample return missions to investigate lava flow diversity and petrological significance.
Green, J; Wright, P A; Gallimore, C I; Mitchell, O; Morgan-Capner, P; Brown, D W
1998-05-01
In May 1994 an outbreak of vomiting and diarrhoea occurred in a 28-bed long-stay ward for the mentally infirm. The predominant symptoms were vomiting, diarrhoea, malaise and abdominal pain lasting for approximately 12 h in most cases. The attack rate was 62% (13/21) for patients and 46% (16/35) for staff members. Infection control measures were implemented (containment of infectious individuals, hand hygiene among staff and environmental decontamination) and the ward was closed to admissions. Affected staff were excluded from contact with patients and their food until asymptomatic for 72 h. The outbreak lasted for 17 days. Faecal samples from nine symptomatic persons were negative for bacterial enteric pathogens, Giardia, Cryptosporidium and group A rotavirus. Electron microscopy of 12 faecal samples and one sample of vomitus revealed small round structured virus (SRSV) particles in one faecal sample. A further 30 faecal samples and seven vomitus samples were tested by reverse transcription polymerase chain reaction (RT-PCR) for SRSV of which 12 (40%) and 1 (14%) were positive respectively. Twenty-eight throat swabs from symptomatic and asymptomatic patients were collected, three (9.5%) of which were positive for SRSV by RT-PCR. Thirty-six environmental swabs were collected on the affected ward, and 11 (30%) were positive by RT-PCR. Positive swabs were from lockers, curtains and commodes and confined to the immediate environment of symptomatic patients. The distribution of contamination supports the rationale of cohorting sick patients.
Alabama Army Ammunition Plant, Talladega County, Alabama
1995-05-10
Facility 21 5.2 Study Area 3 - Sanitary Landfill and Lead Facility 21 5.3 Study Area 4 - Manhattan Project Area 22 5.4 Study Area 5 - Red-Water Storage...were also collected and analyzed. One sample contained a low level of extractable lead. 5.3 Study Area 4 - Manhattan Project Area: Located in the...western portion of the General Services Administration area, the Manhattan Project used a small part of the ALAAP from 1943 to 1945. According to a lefter
Guerrero, R.; Bain, O.
2011-01-01
Parasitic nematodes from the Berlin (ZMB) and Vienna (NMW) Museum collections referred to the genus Filaria Mueller, 1787 by von Linstow or Molin were studied. Three samples were in good condition and the specimens redescribed. Litomosa hepatica (von Linstow, 1897) n. comb., sample ZMB Vermes Entozoa 3368, from the megachiropteran Pteropus neohibernicus, Bismarck Archipelago, resembles L. maki Tibayrenc, Bain & Ramanchandran, 1979, from Pteropus vampyrus, in Malaysia, but the buccal capsule differs. Both species display particular morphological characters which differ from species of Litomosa parasitic in microchiropterans. The remaining material originates from Brazil. The spicule morphology of Litomosoides circularis (von Linstow, 1899) Chandler, 1931, sample ZMB Vermes Entozoa 1059 from Hesperomys spec. (= Holochilus brasiliensis), Porto Alegre, confirms that it belongs to the sigmodontis group; the microfilaria presents characters of the genus Litomosoides, e.g. body attenuated at both extremities and salient cephalic hook. Taxonomic discussions by others confirm that species of Litomosoides belonging to the sigmodontis group and described subsequently are distinct from L. circularis. Litomosoides serpicula (Molin, 1858) Guerrero, Martin, Gardner & Bain, 2002, is redescribed, sample NMW 6323 from the bat Phyllostoma spiculatum (= Sturnira lilium), Ypanema. It is very close to L. brasiliensis Almeida, 1936, type host Moytis sp., but distinguished by a single ring in the buccal capsule, rather than two, supporting previous conclusions that the taxon L. brasiliensis, as generally regarded, may represent a complex of species. Samples NMW 6322 and NMW 6324, from other bats and also identified by Molin (1858) as Filaria serpicula, contain unidentifiable fragments of Litomosoides incertae sedis. Filaria hyalina von Linstow, 1890, sample ZMB Vermes Entozoa Q 3905 from Sorex vulgaris (= Sorex araneus), is incertae sedis because it contains two unidentifiable posterior parts of male, which might be an acuarid, Stammerinema sp. Filaria vesperuginis von Linstow, 1885, sample ZMB Vermes Entozoa Q 3929, from the bat Vesperugo serotinus (= Eptesicus serotinus), contains encysted nematode larvae and is a nomen dubium. PMID:21678791
Kulawik, Piotr; Dordevic, Dani; Gambuś, Florian; Szczurowska, Katarzyna; Zając, Marzena
2018-05-01
The present study determined the heavy metal contamination (mercury, cadmium, lead, arsenic and nickel) of nori, restaurant-served sushi and ready-to-eat sushi meals available via retail chains. Moreover, both microbiological load and biogenic amine content in ready-to-eat sushi meals were analysed. All of the nori samples contained high levels of Cd (2.122 mg kg -1 ), Ni (0.715 mg kg -1 ), As (34.56 mg kg -1 ) and Pb (0.659 mg kg -1 ). The studied sushi samples contained high levels of Ni and Pb, reaching 0.194 and 0.142 mg kg -1 wet weight, respectively, being potentially hazardous to women during pregnancy and lactation and small children. None of the studied samples contained high levels of Hg. Overall, 37% of ready-to-eat sushi meals exceeded a microbiological load of 10 6 cfu g -1 . However, biogenic amine content in all of the samples was low, with a highest histamine content of 2.05 mg kg -1 . Sushi is not the source of high levels of biogenic amines even with high microbiological loads. Nevertheless, the high microbiological loads at the end of the shelf-life indicate that some processors might have problems with the distribution chain or implement a poor hygienic regime. Moreover as a result of possible risk associated with heavy metal contamination, the present study highlights the need to establish new regulations regarding the contamination of nori and sushi. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Acoustic levitation technique for containerless processing at high temperatures in space
NASA Technical Reports Server (NTRS)
Rey, Charles A.; Merkley, Dennis R.; Hammarlund, Gregory R.; Danley, Thomas J.
1988-01-01
High temperature processing of a small specimen without a container has been demonstrated in a set of experiments using an acoustic levitation furnace in the microgravity of space. This processing technique includes the positioning, heating, melting, cooling, and solidification of a material supported without physical contact with container or other surface. The specimen is supported in a potential energy well, created by an acoustic field, which is sufficiently strong to position the specimen in the microgravity environment of space. This containerless processing apparatus has been successfully tested on the Space Shuttle during the STS-61A mission. In that experiment, three samples wer successfully levitated and processed at temperatures from 600 to 1500 C. Experiment data and results are presented.
Exhaled particles as markers of small airway inflammation in subjects with asthma.
Larsson, Per; Lärstad, Mona; Bake, Björn; Hammar, Oscar; Bredberg, Anna; Almstrand, Ann-Charlotte; Mirgorodskaya, Ekaterina; Olin, Anna-Carin
2017-09-01
Exhaled breath contains suspended particles of respiratory tract lining fluid from the small airways. The particles are formed when closed airways open during inhalation. We have developed a method called Particles in Exhaled air (PExA ® ) to measure and sample these particles in the exhaled aerosol. Here, we use the PExA ® method to study the effects of birch pollen exposure on the small airways of individuals with asthma and birch pollen allergy. We hypothesized that birch pollen-induced inflammation could change the concentrations of surfactant protein A and albumin in the respiratory tract lining fluid of the small airways and influence the amount of exhaled particles. The amount of exhaled particles was reduced after birch pollen exposure in subjects with asthma and birch pollen allergy, but no significant effect on the concentrations of surfactant protein A and albumin in exhaled particles was found. The reduction in the number of exhaled particles may be due to inflammation in the small airways, which would reduce their diameter and potentially reduce the number of small airways that open and close during inhalation and exhalation. © 2015 The Authors. Clinical Physiology and Functional Imaging published by John Wiley & Sons Ltd.
Examination of Duct Physiology in the Human Mammary Gland
Mills, Dixie; Gomberawalla, Ameer; Gordon, Eva J.; Tondre, Julie; Nejad, Mitra; Nguyen, Tinh; Pogoda, Janice M.; Rao, Jianyu; Chatterton, Robert; Henning, Susanne; Love, Susan M.
2016-01-01
Background The human breast comprise several ductal systems, or lobes, which contain a small amount of fluid containing cells, hormones, proteins and metabolites. The complex physiology of these ducts is likely a contributing factor to the development of breast cancer, especially given that the vast majority of breast cancers begin in a single lobular unit. Methods We examined the levels of total protein, progesterone, estradiol, estrone sulfate, dehydroepiandrosterone sulfate, and macrophages in ductal fluid samples obtained from 3 ducts each in 78 women, sampled twice over a 6 month period. Samples were processed for both cytological and molecular analysis. Intraclass correlation coefficients and mixed models were utilized to identify significant data. Results We found that the levels of these ductal fluid components were generally uncorrelated among ducts within a single breast and over time, suggesting that each lobe within the breast has a distinct physiology. However, we also found that estradiol was more correlated in women who were nulliparous or produced nipple aspirate fluid. Conclusions Our results provide evidence that the microenvironment of any given lobular unit is unique to that individual unit, findings that may provide clues about the initiation and development of ductal carcinomas. PMID:27073976
Comparative biodegradation of HDPE and LDPE using an indigenously developed microbial consortium.
Satlewal, Alok; Soni, Ravindra; Zaidi, Mgh; Shouche, Yogesh; Goel, Reeta
2008-03-01
A variety of bacterial strains were isolated from waste disposal sites of Uttaranchal, India, and some from artificially developed soil beds containing maleic anhydride, glucose, and small pieces of polyethylene. Primary screening of isolates was done based on their ability to utilize high- and low-density polyethylenes (HDPE/LDPE) as a primary carbon source. Thereafter, a consortium was developed using potential strains. Furthermore, a biodegradation assay was carried out in 500-ml flasks containing minimal broth (250 ml) and HDPE/ LDPE at 5 mg/ml concentration. After incubation for two weeks, degraded samples were recovered through filtration and subsequent evaporation. Fourier transform infrared spectroscopy (FTIR) and simultaneous thermogravimetric-differential thermogravimetry-differential thermal analysis TG-DTG-DTA) were used to analyze these samples. Results showed that consortium-treated HDPE (considered to be more inert relative to LDPE) was degraded to a greater extent 22.41% weight loss) in comparison with LDPE (21.70% weight loss), whereas, in the case of untreated samples, weight loss was more for LDPE than HDPE (4.5% and 2.5%, respectively) at 400 degrees . Therefore, this study suggests that polyethylene could be degraded by utilizing microbial consortia in an eco-friendly manner.
A Holographic Prism Based on Photo-Thermo-Refractive Glass: Requirements and Possibilities
NASA Astrophysics Data System (ADS)
Angervaks, A. E.; Gorokhovskii, K. S.; Granovskii, V. A.; Van Bac, Doan; Ivanov, S. A.; Okun', R. A.; Nikonorov, N. V.; Ryskin, A. I.
2017-12-01
A technology for multivalued holographic measurement of a plane angle—a holographic prism, which serves as the basis for a device for calibrating the testing tools for navigational equipment under rolling— has been developed. The holographic prism is a miniature sample of photosensitive material, which contains a system of superimposed holographic gratings, and a laser the radiation of which passes through gratings to form a fan of diffracted beams. The fan in a prism based on a calcium fluoride (fluorite) crystal with color centers contained six out-of-plane beams radiating from a region with a hard-to-localize center. This fact hindered calibration of the measure and its application in the testing device. The use of photothermo-refractive glass as a material for preparing a sample and recording a system of holograms in it makes it possible to eliminate the drawbacks of fluorite-based prism. The number of holograms rises up to 21, the fan becomes in-plane, and its center is localized in a small region, with a size of several tenths of the sample thickness (1-2 mm). The fan beams are energetically homogeneous, and each can be identified when using the fan in a testing device.
Airborne particles released by crushing CNT composites
NASA Astrophysics Data System (ADS)
Ogura, I.; Okayama, C.; Kotake, M.; Ata, S.; Matsui, Y.; Gotoh, K.
2017-06-01
We investigated airborne particles released as a result of crushing carbon nanotube (CNT) composites using a laboratory scale crusher with rotor blades. For each crushing test, five pellets (approximately 0.1 g) of a polymer (polystyrene, polyamide, or polycarbonate) containing multiwall CNTs (Nanocyl NC7000 or CNano Flotube9000) or no CNTs were placed in the container of the crusher. The airborne particles released by the crushing of the samples were measured. The real-time aerosol measurements showed increases in the concentration of nanometer- and micrometer-sized particles, regardless of the sample type, even when CNT-free polymers were crushed. The masses of the airborne particles collected on filters were below the detection limit, which indicated that the mass ratios of the airborne particles to the crushed pellets were lower than 0.02%. In the electron microscopic analysis, particles with protruding CNTs were observed. However, free-standing CNTs were not found, except for a poorly dispersed CNT-polystyrene composite. This study demonstrated that the crushing test using a laboratory scale crusher is capable of evaluating the potential release of CNTs as a result of crushing CNT composites. The advantage of this method is that only a small amount of sample (several pieces of pellets) is required.
Schumacher, John G.; Struckhoff, Garrett C.; Burken, Joel G.
2004-01-01
Tree-core sampling has been a reliable and inexpensive tool to quickly assess the presence of shallow (less than about 30 feet deep) tetrachloroethene (PCE) and trichloroethene (TCE) contamination in soils and ground water at the Riverfront Superfund Site. This report presents the results of tree-core sampling that was successfully used to determine the presence and extent of chlorinated solvent contamination at two sites, the Front Street site (operable unit OU1) and the former dry cleaning facility, that are part of the overall Riverfront Superfund Site. Traditional soil and ground-water sampling at these two sites later confirmed the results from the tree-core sampling. Results obtained from the tree-core sampling were used to design and focus subsequent soil and ground-water investigations, resulting in substantial savings in time and site assessment costs. The Front Street site is a small (less than 1-acre) site located on the Missouri River alluvium in downtown New Haven, Missouri, about 500 feet from the south bank of the Missouri River. Tree-core sampling detected the presence of subsurface PCE contamination at the Front Street site and beneath residential property downgradient from the site. Core samples from trees at the site contained PCE concentrations as large as 3,850 mg-h/kg (micrograms in headspace per kilogram of wet core) and TCE concentrations as large as 249 mg-h/kg. Soils at the Front Street site contained PCE concentrations as large as 6,200,000 mg/kg (micrograms per kilogram) and ground-water samples contained PCE concentrations as large as 11,000 mg/L (micrograms per liter). The former dry cleaning facility is located at the base of the upland that forms the south bank of the Missouri River alluvial valley. Tree-core sampling did not indicate the presence of PCE or TCE contamination at the former dry cleaning facility, a finding that was later confirmed by the analyses of soil samples collected from the site. The lateral extent of PCE contamination in trees was in close agreement with the extent of subsurface PCE contamination determined using traditional soil and ground-water sampling methods. Trees growing in soils containing PCE concentrations of 60 to 5,700 mg/kg or larger or overlying ground water containing PCE concentrations from 5 to 11,000 mg/L generally contained detectable concentrations of PCE. The depth to contaminated ground water was about 20 to 25 feet below the land surface. Significant quantitative relations [probability (p) values of less than 0.05 and correlation coefficient (r2) values of 0.88 to 0.90] were found between PCE concentrations in trees and subsurface soils between 4 and 16 feet deep. The relation between PCE concentrations in trees and underlying ground water was less apparent (r2 value of 0.17) and the poor relation is thought to be the result of equilibrium with PCE concentrations in soil and vapor in the unsaturated zone. Based on PCE concentrations detected in trees at the Front Street site and trees growing along contaminated tributaries in other operable units, and from field hydroponic experiments using hybrid poplar cuttings, analysis of tree-core samples appears to be able to detect subsurface PCE contamination in soils at levels of several hundred micrograms per liter or less and PCE concentrations in the range of 8 to 30 mg/L in ground water in direct contact with the roots. Loss of PCE from tree trunks by diffusion resulted in an exponential decrease in PCE concentrations with increasing height above the land surface in most trees. The rate of loss also appeared to be a function of the size and growth characteristics of the tree as some trees exhibited a linear loss with increasing height. Diffusional loss of PCE in small (0.5-inch diameter) trees was observed to occur at a rate more than 10 times larger than in trees 6.5 inches in diameter. Concentrations of PCE also exhibited directional variability around the tree trunks and concentration differe
Standardized Curriculum for Small Engine Repair.
ERIC Educational Resources Information Center
Mississippi State Dept. of Education, Jackson. Office of Vocational, Technical and Adult Education.
This curriculum guide for small engine repair was developed by the state of Mississippi to standardize vocational education course titles and core contents. The objectives contained in this document are common to all small engine repair programs in the state. The guide contains objectives for small engine repair I and II courses. Units in course I…
Improved aqueous scrubber for collection of soluble atmospheric trace gases
NASA Technical Reports Server (NTRS)
Cofer, W. R., III; Talbot, R. W.; Collins, V. G.
1985-01-01
A new concentration technique for the extraction and enrichment of water-soluble atmospheric trace gases has been developed. The gas scrubbing technique efficiently extracts soluble gases from a large volume flow rate of air sample into a small volume of refluxed trapping solution. The gas scrubber utilizes a small nebulizing nozzle that mixes the incoming air with an aqueous extracting solution to form an air/droplet mist. The mist provides excellent interfacial surface areas for mass transfer. The resulting mist sprays upward through the reaction chamber until it impinges upon a hydrophobic membrane that virtually blocks the passage of droplets but offers little resistance to the existing gas flow. Droplets containing the scrubbed gases coalesce on the membrane and drip back into the reservoir for further refluxing. After a suitable concentration period, the extracting solution containing the analyte can be withdrawn for analysis. The nebulization-reflex concentration technique is more efficient (maximum flow of gas through the minimum volume of extractant) than conventional bubbler/impinger gas extraction techniques and is offered as an alternative method.
More than meets the eye: subretinal aspirate from an acutely blind dog.
Rizzi, Theresa E; Cowell, Rick L; Meinkoth, James H; Gilmour, Margi A
2006-03-01
A 14-year-old, spayed female Cocker Spaniel was presented to the Boren Veterinary Medical Teaching Hospital at Oklahoma State University with acute loss of vision in the right eye and a history of intermittent bloody diarrhea of unknown duration. Small, white, plaque-like lesions in the retina and subretina were visualized by direct ophthalmic examination, and aspirated with ultrasound-guidance. A direct smear of the subretinal fluid was highly cellular and contained large numbers of pleomorphic organisms consistent with Prototheca sp. The structures were round, oval, or elongated, 4-6 microm width and 8-16 microm in length and surrounded by a thin, clear cell wall. Small, central, pink to purple nuclei were observed in some organisms, but in most, the nuclei were obscured by a deeply basophilic, granular cytoplasm. Some organisms contained endospores. Negatively-stained structures of similar size and shape were considered to be empty casings (theca) of ruptured sporulating and nonsporulating forms of the organism. Protothecosis usually is a disseminated, fatal disease in dogs. The Prototheca organisms observed in this case showed characteristic morphology, illustrating the ability to diagnose protothecosis in cytologic samples.
Guelfo, Jennifer L; Adamson, David T
2018-05-01
The United States Environmental Protection Agency (USEPA) completed nationwide screening of six perfluoroalkyl substances in U.S. drinking water from 2013 to 2015 under the Third Unregulated Contaminant Monitoring Rule (UCMR3). UCMR3 efforts yielded a dataset of 36,139 samples containing analytical results from >5000 public water systems (PWSs). This study used UCMR3 data to investigate three aspects of per- and polyfluoroalkyl substances (PFASs) in drinking water: the occurrence of PFAS and co-contaminant mixtures, trends in PFAS detections relative to PWS characteristics and potential release types, and temporal trends in PFAS occurrence. This was achieved through bivariate and multivariate analyses including categorical analysis, concentration ratios, and hierarchical cluster analysis. Approximately 50% of samples with PFAS detections contained ≥2 PFASs, and 72% of detections occurred in groundwater. Large PWSs (>10,000 customers) were 5.6 times more likely than small PWSs (≤10,000 customers) to exhibit PFAS detections; however, when detected, median total PFAS concentrations were higher in small PWSs (0.12 μg/L) than in large (0.053 μg/L). Bivariate and multivariate analyses of PFAS composition suggested PWSs reflect impacts due to firefighting foam use and WWTP effluent as compared to other source types for which data were available. Mann-Kendall analysis of quarterly total PFAS detection rates indicated an increasing trend over time (p = 0.03). UCMR3 data provide a foundation for tiered design of targeted sampling and analysis plans to address remaining knowledge gaps in the sources, composition, and concentrations of PFASs in U.S. drinking water. Copyright © 2018 Elsevier Ltd. All rights reserved.
Scalable Performance Measurement and Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gamblin, Todd
2009-01-01
Concurrency levels in large-scale, distributed-memory supercomputers are rising exponentially. Modern machines may contain 100,000 or more microprocessor cores, and the largest of these, IBM's Blue Gene/L, contains over 200,000 cores. Future systems are expected to support millions of concurrent tasks. In this dissertation, we focus on efficient techniques for measuring and analyzing the performance of applications running on very large parallel machines. Tuning the performance of large-scale applications can be a subtle and time-consuming task because application developers must measure and interpret data from many independent processes. While the volume of the raw data scales linearly with the number ofmore » tasks in the running system, the number of tasks is growing exponentially, and data for even small systems quickly becomes unmanageable. Transporting performance data from so many processes over a network can perturb application performance and make measurements inaccurate, and storing such data would require a prohibitive amount of space. Moreover, even if it were stored, analyzing the data would be extremely time-consuming. In this dissertation, we present novel methods for reducing performance data volume. The first draws on multi-scale wavelet techniques from signal processing to compress systemwide, time-varying load-balance data. The second uses statistical sampling to select a small subset of running processes to generate low-volume traces. A third approach combines sampling and wavelet compression to stratify performance data adaptively at run-time and to reduce further the cost of sampled tracing. We have integrated these approaches into Libra, a toolset for scalable load-balance analysis. We present Libra and show how it can be used to analyze data from large scientific applications scalably.« less
Determination of VOC emission rates and compositions for offset printing.
Wadden, R A; Scheff, P A; Franke, J E; Conroy, L M; Keil, C B
1995-07-01
The release rates of volatile organic compounds (VOC) as fugitive emissions from offset printing are difficult to quantify, and the compositions are usually not known. Tests were conducted at three offset printing shops that varied in size and by process. In each case, the building shell served as the test "enclosure," and air flow and concentration measurements were made at each air entry and exit point. Emission rates and VOC composition were determined during production for (1) a small shop containing three sheetfed presses and two spirit duplicators (36,700 sheets, 47,240 envelopes and letterheads), (2) a medium-size industrial in-house shop with two webfed and three sheetfed presses, and one spirit duplicator (315,130 total sheets), and (3) one print room of a large commercial concern containing three webfed, heatset operations (1.16 x 10(6) ft) served by catalytic air pollution control devices. Each test consisted of 12 one-hour periods over two days. Air samples were collected simultaneously during each period at 7-14 specified locations within each space. The samples were analyzed by gas chromatography (GC) for total VOC and for 13-19 individual organics. Samples of solvents used at each shop were also analyzed by GC. Average VOC emission rates were 4.7-6.1 kg/day for the small sheetfed printing shop, 0.4-0.9 kg/day for the industrial shop, and 79-82 kg/day for the commercial print room. Emission compositions were similar and included benzene, toluene, xylenes, ethylbenzene, and hexane. Comparison of the emission rates with mass balance estimates based on solvent usage and composition were quite consistent.(ABSTRACT TRUNCATED AT 250 WORDS)
Sun, Zehang; Xie, Xiande; Wang, Ping; Hu, Yuanan; Cheng, Hefa
2018-10-15
Although metal ore mining activities are well known as an important source of heavy metals, soil pollution caused by small-scale mining activities has long been overlooked. This study investigated the pollution of surface soils in an area surrounding a recently abandoned small-scale polymetallic mining district in Guangdong province of south China. A total of 13 tailing samples, 145 surface soil samples, and 29 water samples were collected, and the concentrations of major heavy metals, including Cr, Mn, Co, Ni, Cu, Zn, As, Cd, Pb, and Se, were determined. The results show that the tailings contained high levels of heavy metals, with Cu, Zn, As, Cd, and Pb occurring in the ranges of 739-4.15 × 10 3 , 1.81 × 10 3 -5.00 × 10 3 , 118-1.26 × 10 3 , 8.14-57.7, and 1.23 × 10 3 -6.99 × 10 3 mg/kg, respectively. Heavy metals also occurred at high concentrations in the mine drainages (15.4-17.9 mg/L for Cu, 21.1-29.3 mg/L for Zn, 0.553-0.770 mg/L for Cd, and 1.17-2.57 mg/L for Pb), particularly those with pH below 3. The mean contents of Cu, Zn, As, Cd, and Pb in the surface soils of local farmlands were up to 7 times higher than the corresponding background values, and results of multivariate statistical analysis clearly indicate that Cu, Zn, Cd, and Pb were largely contributed by the mining activities. The surface soils from farmlands surrounding the mining district were moderately to seriously polluted, while the potential ecological risk of heavy metal pollution was extremely high. It was estimated that the input fluxes from the mining district to the surrounding farmlands were approximately 17.1, 59.2, 0.311, and 93.8 kg/ha/yr for Cu, Zn, Cd, and Pb, respectively, which probably occurred through transport of fine tailings by wind and runoff, and mine drainage as well. These findings indicate the significant need for proper containment of the mine tailings at small-scale metal ore mines. Copyright © 2018. Published by Elsevier B.V.
Source, movement and age of groundwater in the upper part of the Mojave River Basin, California, USA
Izbicki, J.A.; Martin, P.; Michel, R.L.
1995-01-01
Water samples from wells were collected and analysed for oxygen-18, deuterium, tritium, carbon-14, and carbon-13 to determine the source, movement and age of groundwater in the upper part of the Mojave River basin. Water in the alluvial aquifer has a median deuterium composition of -66??? and contains tritium, and was recently recharged by water from the Mojave River. Water in the regional aquifer near the Mojave River, near Summit Valley, and underlying several small washes has deuterium compositions heavier than -60???. Although some water in the regional aquifer near the Mojave River contains tritium, most of this water does not contain tritium. Carbon-14 data indicate that this water was recharged less than 2400 years ago. Water in the remainder of the regional aquifer has a median deuterium composition of -84???, which is as much as 20??? lighter than the volume-weighted deuterium composition of present-day precipitation. These data show that this water was recharged under climatic conditions different from average conditions today. Carbon-14 data indicate that some water in the regional aquifer was recharged more than 20 000 years ago.Water samples from wells were collected and analyzed for oxygen-18, deuterium, tritium, carbon-14, and carbon-13 to determine the source, movement and age of groundwater in the upper part of the Mojave River basin. Water in the alluvial aquifer has a median deuterium composition of -66qq and contains tritium, and was recently recharged by water from the Mojave River. Water in the regional aquifer near the Mojave River, near Summit Valley, and underlying several small washes has deuterium compositions heavier than -60qq. Although some water in the regional aquifer near the Mojave River contains tritium, most of this water does not contain tritium. Carbon-14 data indicate that this water was recharged less than 2400 years ago. Water in the remainder of the regional aquifer has a median deuterium composition of -84qq, which is as much as 20qq lighter than the volume-weighted deuterium composition of present-day precipitation. These data show that this water was recharged under climatic conditions different from average conditions today. Carbon-14 data indicate that some water in the regional aquifer was recharged more than 20 000 years ago.
Gode, David; Volmer, Dietrich A
2013-05-15
Magnetic beads are often used for serum profiling of peptide and protein biomarkers. In these assays, the bead-bound analytes are eluted from the beads prior to mass spectrometric analysis. This study describes a novel matrix-assisted laser desorption/ionization (MALDI) technique for direct application and focusing of magnetic beads to MALDI plates by means of dedicated micro-magnets as sample spots. Custom-made MALDI plates with magnetic focusing spots were made using small nickel-coated neodymium micro-magnets integrated into a stainless steel plate in a 16 × 24 (384) pattern. For demonstrating the proof-of-concept, commercial C-18 magnetic beads were used for the extraction of a test compound (reserpine) from aqueous solution. Experiments were conducted to study focusing abilities, the required laser energies, the influence of a matrix compound, dispensing techniques, solvent choice and the amount of magnetic beads. Dispensing the magnetic beads onto the micro-magnet sample spots resulted in immediate and strong binding to the magnetic surface. Light microscope images illustrated the homogeneous distribution of beads across the surfaces of the magnets, when the entire sample volume containing the beads was pipetted onto the surface. Subsequent MALDI analysis of the bead-bound analyte demonstrated excellent and reproducible ionization yields. The surface-assisted laser desorption/ionization (SALDI) properties of the strongly light-absorbing γ-Fe2O3-based beads resulted in similar ionization efficiencies to those obtained from experiments with an additional MALDI matrix compound. This feasibility study successfully demonstrated the magnetic focusing abilities for magnetic bead-bound analytes on a novel MALDI plate containing small micro-magnets as sample spots. One of the key advantages of this integrated approach is that no elution steps from magnetic beads were required during analyses compared with conventional bead experiments. Copyright © 2013 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Lininger, K.; Wohl, E.; Rose, J. R.
2016-12-01
High latitude permafrost regions contain large amounts of organic carbon (OC) in the subsurface, but little work has quantified OC storage in floodplain sediment in the high latitudes. Floodplains influence the export of OC to the ocean by temporarily storing OC at timescales of 101 to 103 years. To fully understand terrestrial carbon cycling, the storage and residence time of OC in floodplains, and the geomorphic controls on OC storage, must be taken into account. Small-scale spatial variations in OC storage within floodplains likely reflect geomorphic processes of deposition and floodplain development. We present results of floodplain OC storage and residence time in sediment along 5 rivers in the Yukon Flats National Wildlife Refuge in interior Alaska, a region with discontinuous permafrost. We collected sediment samples within the active layer along tributaries to the Yukon River and the mainstem Yukon River and analyzed the sediment samples for OC content. We classified sample locations by geomorphic type (filled secondary channels, levees, point bars) and vegetation type (herbaceous, deciduous/shrub, white spruce, and black spruce wetlands), and found that both geomorphology and vegetation influence OC concentration and OC mass per area. Preliminary results suggest that filled secondary channels contain more OC per area compared to other geomorphic types. We present results of radiocarbon dates from river cutbanks associated with our sampling sites, which give a maximum age for residence times of OC in sediment before erosion and transport. The radiocarbon dates also provide estimates of long-term OC accretion within the Yukon Flats floodplains. Small-scale variations within floodplains as a result of floodplain depositional processes and vegetation communities shed light on the geomorphic controls on OC storage. This work will help constrain the spatial variation in OC storage and OC residence time across the landscape in a region experiencing rapid climate change and permafrost thaw.
Fast Cooling and Vitrification of Aqueous Solutions for Cryopreservation
NASA Astrophysics Data System (ADS)
Warkentin, Matt; Husseini, Naji; Berejnov, Viatcheslav; Thorne, Robert
2006-03-01
In many applications, a small volume of aqueous solution must be cooled at a rate sufficient to produce amorphous solid water. Two prominent examples include flash-freezing of protein crystals for X-ray data collection and freezing of cells (i.e. spermatozoa) for cryopreservation. The cooling rate required to vitrify pure water (˜10^6 K/s) is unattainable for volumes that might contain cells or protein crystals, but the required rate can be reduced by adding cryoprotectants. We report the first measurements of the critical concentration required to produce a vitrified sample as a function of the sample's volume, the cryogen into which the sample is plunged, and the temperature of the cryogen, for a wide range of cryoprotectants. These experiments have broad practical consequences for cryopreservation, and provide insight into the physics of glass formation in aqueous systems.
Cristiglio, Viviana; Grillo, Isabelle; Fomina, Margarita; Wien, Frank; Shalaev, Evgenyi; Novikov, Alexey; Brassamin, Séverine; Réfrégiers, Matthieu; Pérez, Javier; Hennet, Louis
2017-01-01
The acoustic levitation technique is a useful sample handling method for small solid and liquids samples, suspended in air by means of an ultrasonic field. This method was previously used at synchrotron sources for studying pharmaceutical liquids and protein solutions using x-ray diffraction and small angle x-ray scattering (SAXS). In this work we combined for the first time this containerless method with small angle neutron scattering (SANS) and synchrotron radiation circular dichroism (SRCD) to study the structural behavior of proteins in solutions during the water evaporation. SANS results are also compared with SAXS experiments. The aggregation behavior of 45μl droplets of lysozyme protein diluted in water was followed during the continuous increase of the sample concentration by evaporating the solvent. The evaporation kinetics was followed at different drying stage by SANS and SAXS with a good data quality. In a prospective work using SRCD, we also studied the evolution of the secondary structure of the myoglobin protein in water solution in the same evaporation conditions. Acoustic levitation was applied for the first time with SANS and the high performances of the used neutron instruments made it possible to monitor fast container-less reactions in situ. A preliminary work using SRCD shows the potentiality of its combination with acoustic levitation for studying the evolution of the protein structure with time. This multi-techniques approach could give novel insights into crystallization and self-assembly phenomena of biological compound with promising potential applications in pharmaceutical, food and cosmetics industry. This article is part of a Special Issue entitled "Science for Life" Guest Editor: Dr. Austen Angell, Dr. Salvatore Magazù and Dr. Federica Migliardo. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Shcherbakov, V. P.; Shcherbakova, V. V.
2001-07-01
We report an experimental and theoretical study of non-linear Arai-Nagata diagrams for samples containing pseudo-single-domain (PSD) and multidomain (MD) magnetite. Our aim is to reveal the physical reasons for the deviation of these plots from ideal straight lines. Contrary to expectations, the concavity of the Arai-Nagata diagrams is not related to the two most noticeable violations of the Thellier laws documented for non-single-domain particles: the tail of partial thermoremanence and the dependence of the magnitude of pTRM on the thermal history of the sample. Indeed, the contributions from these two factors mutually cancel each other. Phenomenologically, the non-linear Arai-Nagata plots occur because samples during low-temperature stages of the Thellier procedure lose too much remanence and recover too little of it. The excessive loss of the previously imparted total TRM is due at least partly to some partial demagnetization of high-temperature TRM components and to progressive stabilization of domain structure during the repetitive heatings to moderate temperatures that form the basis of the Thellier procedure. For natural MD samples a linear fit to the low-temperature data points on the Arai-Nagata plots leads to a palaeointensity overestimated by as much as 60 per cent. The samples containing hydrothermally grown or crushed and sieved MD magnetite provide low-temperature apparent palaeointensities two to three times larger than the correct value. For small PSD samples the overestimate is less than 10-20 per cent and, in general, PSD samples can be used for the palaeointensity determinations.
Soil sampling kit and a method of sampling therewith
Thompson, Cyril V.
1991-01-01
A soil sampling device and a sample containment device for containing a soil sample is disclosed. In addition, a method for taking a soil sample using the soil sampling device and soil sample containment device to minimize the loss of any volatile organic compounds contained in the soil sample prior to analysis is disclosed. The soil sampling device comprises two close fitting, longitudinal tubular members of suitable length, the inner tube having the outward end closed. With the inner closed tube withdrawn a selected distance, the outer tube can be inserted into the ground or other similar soft material to withdraw a sample of material for examination. The inner closed end tube controls the volume of the sample taken and also serves to eject the sample. The soil sample containment device has a sealing member which is adapted to attach to an analytical apparatus which analyzes the volatile organic compounds contained in the sample. The soil sampling device in combination with the soil sample containment device allow an operator to obtain a soil sample containing volatile organic compounds and minimizing the loss of the volatile organic compounds prior to analysis of the soil sample for the volatile organic compounds.
Soil sampling kit and a method of sampling therewith
Thompson, C.V.
1991-02-05
A soil sampling device and a sample containment device for containing a soil sample is disclosed. In addition, a method for taking a soil sample using the soil sampling device and soil sample containment device to minimize the loss of any volatile organic compounds contained in the soil sample prior to analysis is disclosed. The soil sampling device comprises two close fitting, longitudinal tubular members of suitable length, the inner tube having the outward end closed. With the inner closed tube withdrawn a selected distance, the outer tube can be inserted into the ground or other similar soft material to withdraw a sample of material for examination. The inner closed end tube controls the volume of the sample taken and also serves to eject the sample. The soil sample containment device has a sealing member which is adapted to attach to an analytical apparatus which analyzes the volatile organic compounds contained in the sample. The soil sampling device in combination with the soil sample containment device allows an operator to obtain a soil sample containing volatile organic compounds and minimizing the loss of the volatile organic compounds prior to analysis of the soil sample for the volatile organic compounds. 11 figures.
Toward MRI microimaging of single biological cells
NASA Astrophysics Data System (ADS)
Seeber, Derek Allan
There is a great advantage in signal to noise ratio (SNR) that can be obtained in nuclear magnetic resonance (NMR) on very small samples (having spatial dimensions ˜100 mum or less) if one employs NMR "microcoils" that are of similarly small dimensions. These gains in SNR could enable magnetic resonance imaging (MRI) microscopy with spatial resolutions of ˜1--2 mum, much better than currently available. We report the design and testing of a NMR microcoil receiver apparatus, employing solenoidal microcoils of dimensions of tens to hundreds of microns, using an applied field of 9 Tesla (proton frequency 383 MHz). For the smallest receiver coils we attain sensitivity sufficient to observe proton NMR with SNR one in a single scan applied to ˜10 mum3 (10 fl) water sample, containing 7 x 1011 total proton spins. In addition to the NMR applications, microcoils have been applied to MRI producing images with spatial resolutions as low as 2 mum x 3.5 mum x 14.8 mum on phantom images of rods and beads. This resolution can be further improved. MRI imaging of small sample volumes requires significant hardware modifications and improvements, all of which are discussed. Specifically, MRI microscopy requires very strong (>10 T/m), rapidly switchable triaxial magnetic field gradients. We report the design and construction of such a triaxial gradient system, producing gradient substantially greater than 15 T/m in all three directions, x, y, and z (as high as 50 T/m for the x direction). The gradients are power by a custom designed power supply capable of providing currents in excess of 200 amps and switching times of less than 5 mus corresponding to slew rates of greater that 107 T/m/s. The gradients are adequately uniform (within 5% over a volume of 600 mum3) and sufficient for microcoil MRI of small samples.
Cao, K F; Zhang, H H; Han, H H; Song, Y; Bai, X L; Sun, H
2016-05-01
In this study, we comprehensively investigated the effect of dietary protein sources on the gut microbiome of weaned piglets with diets comprising different protein source using High-throughput 16SrRNA gene-based Illumina Miseq. A total of 48 healthy weaned piglets were allocated randomly to four treatments with 12 piglets in each group. The weaned piglets were fed with diets containing soybean meal (SBM), cottonseed meal (CSM), SBM and CSM (SC) or fish meal (FM). The intestinal content samples were taken from five segments of the small intestine. DNA was extracted from the samples and the V3-V4 regions of the 16SrRNA gene were amplified. The microbiota of the contents of the small intestine were very complex, including more than 4000 operational taxonomic units belonging to 32 different phyla. Four bacterial populations (i.e. Firmicutes, Proteobacteria, Bacteroidetes and Acidobacteria) were the most abundant bacterial groups. The genera Lactobacillus and Clostridium were found in slightly higher proportions in the groups with added CSM compared to the other groups. The proportion of reads assigned to the genus Escherichia/Shigella was much higher in the FM group. In conclusion, dietary protein source had significant effects on the small microbiome of weaned piglets. Dietary protein source have the potential to affect the small intestine microbiome of weaned piglets that will have a large impact on its metabolic capabilities and intestinal health. In this study, we successfully identified the microbiomes in the contents of the small intestine in the weaned piglets that were fed different protein source diets using high-throughput sequencing. The finding provided an evidence for the option of the appropriate protein source in the actual production. © 2016 The Society for Applied Microbiology.
Mars Immunoassay Life Detection Instrument (MILDI)
NASA Technical Reports Server (NTRS)
McKay, David; Steele, Andrew; Allen, Carlton; Thomas-Kepta, Kathie; Schweitzer, Mary; Priscu, John; Sears, Joe; Avci, Recep; Firman, Keith
2000-01-01
The direct detection of organic biomarkers for living or fossil microbes on Mars by an in situ instrument is a worthy goal for future lander missions. We have proposed an instrument based on immunological reactions to specific antibodies to cause activation of fluorescent stains. Antibodies are raised or acquired to a variety of general and specific substances that might be in Mars soil. These antibodies are then combined with various fluorescent stains and applied to small numbered spots on a small (two to three centimeters) test plate where they become firmly attached after drying. On Mars, a sample of soil from a trench or drill core is extracted with water and/or an organic solvent that is then applied to the test plate. Any substance, which has an antibody on the test plate, will react with its antibody and activate its fluorescent stain. A small ultraviolet light source will illuminate the test plate, which is observed with a small CCD camera. The numbered spots that fluoresce indicate the presence of the tested-for substance, and the intensity indicates relative amounts. The entire instrument can be quite small and light, on the order of ten cm in each dimension. A possible choice for light source may be small UV lasers at several wavelengths. Up to 1000 different sample spots can be placed on a plate 3 cm on a side, but a more practical number might be 100. Each antibody can have a redundant position for independent verification of reaction. Some of the wells or spots can contain simply standard fluorescent stains used to detect live cells, dead cells, DNA, etc. These the stains in these spots may be directly activated; no antibodies are necessary.
Effects of various fiber additions on lipid digestion during in vitro digestion of beef patties.
Hur, S J; Lim, B O; Park, G B; Joo, S T
2009-01-01
The purpose of this study was to examine the effect of various fiber additions on lipid digestion during the in vitro digestion of beef patties. The control patties were prepared with 90.5% lean meat and 9.5% tallow. Treatments consisted of 90% lean meat with 9.5% tallow and either 0.5% cellulose, 0.5% chitosan, or 0.5% pectin. The beef patties were then passed through an in vitro digestion model that simulated the composition of the mouth, stomach, and small intestine juices. The change in structure and properties of the lipid droplets was monitored by laser scanning confocal fluorescence microscopy. In general, there was a decrease in lipid droplet diameter as the droplets moved from mouth to stomach to small intestine. The amount of free fatty acid dramatically increased after in vitro digestion in all beef patties. The amount of free fatty acid was, however, lower in beef patties containing chitosan and pectin than other beef patties after in vitro digestion. Beef patties containing various fibers had lower thiobarbituric acid-reactive substances (TBARS) values than samples with no fibers. Among the samples to which fibers were added, chitosan and pectin had lower TBARS than beef patties with cellulose. The cholesterol content decreased after in vitro digestion in all beef patties but was not different among the beef patties before and after in vitro digestion. These results enhance our understanding of the physicochemical and structural changes that occur to ground beef within the gastrointestinal tract.
NASA Astrophysics Data System (ADS)
Briguglio, Antonino; Goeting, Sulia; Kusli, Rosnani; Roslim, Amajida; Polgar, Gianluca; Kocsis, Laszlo
2016-04-01
For this study, 11 samples have been collected by scuba diving from 5 to 35 meters water depth off shore Brunei Darussalam. The locations sampled are known as: Pelong Rock (5 samples, shallow reef with soft and stony corals and larger foraminifera, 5 to 8 meters water depth), Abana Rock (1 sample, shallow reef with mainly soft corals and larger foraminifera, 13 to 18 meters water depth), Oil Rig wreck (1 sample, very sandy bottom with larger foraminifera, 18 meters water depth), Dolphin wreck (1 sample, muddy sand with many small rotaliids, 24 meters water depth), US wreck, (1 sample, sand with small clay fraction, 28 meters water depth), Australian wreck (1 sample, mainly medium to coarse sand with larger foraminifera, 34 meters water depth) and Blue water wreck (1 sample, mainly coarse sand, coral rubble and larger foraminifera, 35 meters water depth). Those samples closer to the river inputs are normally richer in clay, while the most distant samples are purely sandy. Some additional samples have been collected next to reef environments which, even if very shallow, are mainly sandy with almost no clay fraction. The deepest sample, which is 30 km offshore, contains some planktonic foraminifera and is characterized by a large range of preservations concerning foraminifera, thus testifying the presence or relict sediments at the sea bottom. The presence of relict sediments was already pointed out by older oil-related field studies offshore Brunei Darussalam, and now it is possible to draw the depth limit of these deposits. The diversity of the benthic foraminiferal fauna is relatively high but not as higher as neighboring regions as some studies have highlighted. The species collected and identified are more than 50: in reef environment the most abundant are Calcarina defrancii, Neorotalia calcar and the amphisteginidae; deeper in the muddy sediments the most abundant is Pararotalia schroeteriana and in the deepest sandy sample the most abundant are Calcarina hispida, followed by Operculina ammonoides.
Why we need asteroid sample return mission?
NASA Astrophysics Data System (ADS)
Barucci, Maria Antonietta
2016-07-01
Small bodies retain evidence of the primordial solar nebula and the earliest solar system processes that shaped their evolution. They may also contain pre-solar material as well as complex organic molecules, which could have a major role to the development of life on Earth. For these reasons, asteroids and comets have been targets of interest for missions for over three decades. However, our knowledge of these bodies is still very limited, and each asteroid or comet visited by space mission has revealed unexpected scientific results, e.g. the structure and nature of comet 67P/Churyumov-Gerasimenko (67P/C-G) visited by the Rosetta mission. Only in the laboratory can instruments with the necessary precision and sensitivity be applied to individual components of the complex mixture of materials that forms a small body regolith, to determine their precise chemical and isotopic composition. Such measurements are vital for revealing the evidence of stellar, interstellar medium, pre-solar nebula and parent body processes that are retained in primitive material, unaltered by atmospheric entry or terrestrial contamination. For those reasons, sample return missions are considered a high priority by a number of the leading space agencies. Abundant within the inner Solar System and the main impactors on terrestrial planets, small bodies may have been the principal contributors of the water and organic material essential to create life on Earth. Small bodies can therefore be considered to be equivalent to DNA for unravelling our solar system's history, offering us a unique window to investigate both the formation of planets and the origin of life. A sample return mission to a primitive Near-Earth Asteroid (NEA) has been study at ESA from 2008 in the framework of ESA's Cosmic Vision (CV) programme, with the objective to answer to the fundamental CV questions "How does the Solar System work?" and "What are the conditions for life and planetary formations?". The returned material will allow us to study in terrestrial laboratories some of the most primitive materials available to investigate early solar system formation processes, to explore initial stages of habitable planet formation, to identify and characterize the organics and volatiles in a primitive asteroid. The ideal easy target body for such mission is a D type NEA. D types are the most abundant asteroids beyond the outer edge of the main belt. It is likely that they formed much further out in the Solar System, possibly as far as the transneptunian objects, and were subsequently captured in their present locations following the migration of the gas giants. Spectral features indicate that these bodies are organic rich, contain fine anhydrous minerals but also may be volatile rich and appear to be the most primitive rocky material present in the solar system. In addition to addressing the major science goals, sample return mission from a NEA also involved innovative European technologies. The key sample return capabilities, i.e. asteroid navigation, touch and go, sampling mechanism and the re-entry capsule have reached at ESA a validation status to enter implementation phase. The development of sample return technology represents in Europe a crucial element for planetary science and for the space technology development.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anovitz, Lawrence; Cole, David; Rother, Gernot
2013-01-01
Small- and Ultra-Small Angle Neutron Scattering (SANS and USANS) provide powerful tools for quantitative analysis of porous rocks, yielding bulk statistical information over a wide range of length scales. This study utilized (U)SANS to characterize shallowly buried quartz arenites from the St. Peter Sandstone. Backscattered electron imaging was also used to extend the data to larger scales. These samples contain significant volumes of large-scale porosity, modified by quartz overgrowths, and neutron scattering results show significant sub-micron porosity. While previous scattering data from sandstones suggest scattering is dominated by surface fractal behavior over many orders of magnitude, careful analysis of ourmore » data shows both fractal and pseudo-fractal behavior. The scattering curves are composed of subtle steps, modeled as polydispersed assemblages of pores with log-normal distributions. However, in some samples an additional surface-fractal overprint is present, while in others there is no such structure, and scattering can be explained by summation of non-fractal structures. Combined with our work on other rock-types, these data suggest that microporosity is more prevalent, and may play a much more important role than previously thought in fluid/rock interactions.« less
On the Importance of Small Ice Crystals in Tropical Anvil Cirrus
NASA Technical Reports Server (NTRS)
Jensen, E. J.; Lawson, P.; Baker, B.; Pilson, B.; Mo, Q.; Heymsfield, A. J.; Bansemer, A.; Bui, T. P.; McGill, M.; Hlavka, D.;
2009-01-01
In situ measurements of ice crystal concentrations and sizes made with aircraft instrumentation over the past two decades have often indicated the presence of numerous relatively small (< 50 m diameter) crystals in cirrus clouds. Further, these measurements frequently indicate that small crystals account for a large fraction of the extinction in cirrus clouds. The fact that the instruments used to make these measurements, such as the Forward Scattering Spectrometer Probe (FSSP) and the Cloud Aerosol Spectrometer (CAS), ingest ice crystals into the sample volume through inlets has led to suspicion that the indications of numerous small ]crystals could be artifacts of large ]crystal shattering on the instrument inlets. We present new aircraft measurements in anvil cirrus sampled during the Tropical Composition, Cloud, and Climate Coupling (TC4) campaign with the 2 ] Dimensional Stereo (2D ]S) probe, which detects particles as small as 10 m. The 2D ]S has detector "arms" instead of an inlet tube. Since the 2D ]S probe surfaces are much further from the sample volume than is the case for the instruments with inlets, it is expected that 2D ]S will be less susceptible to shattering artifacts. In addition, particle inter ]arrival times are used to identify and remove shattering artifacts that occur even with the 2D ]S probe. The number of shattering artifacts identified by the 2D ]S interarrival time analysis ranges from a negligible contribution to an order of magnitude or more enhancement in apparent ice concentration over the natural ice concentration, depending on the abundance of large crystals and the natural small ]crystal concentration. The 2D ]S measurements in tropical anvil cirrus suggest that natural small ]crystal concentrations are typically one to two orders of magnitude lower than those inferred from CAS. The strong correlation between the CAS/2D ]S ratio of small ]crystal concentrations and large ]crystal concentration suggests that the discrepancy is likely caused by shattering of large crystals on the CAS inlet. We argue that past measurements with CAS in cirrus with large crystals present may contain errors due to crystal shattering, and past conclusions derived from these measurements may need to be revisited. Further, we present correlations between CAS spurious concentration and 2D ]S large ]crystal mass from spatially uniform anvil cirrus sampling periods as an approximate guide for estimating quantitative impact of large ]crystal shattering on CAS concentrations in previous datasets. We use radiative transfer calculations to demonstrate that in the maritime anvil cirrus sampled during TC4, small crystals indicated by 2D ]S contribute relatively little cloud extinction, radiative forcing, or radiative heating in the anvils, regardless of anvil age or vertical location in the clouds. While 2D ]S ice concentrations in fresh anvil cirrus may often exceed 1 cm.3, and are observed to exceed 10 cm.3 in turrets, they are typically 0.1 cm.3 and rarely exceed 1 cm.3 (<1.4% of the time) in aged anvil cirrus. We hypothesize that isolated occurrences of higher ice concentrations in aged anvil cirrus may be caused by ice nucleation driven by either small ]scale convection or gravity waves. It appears that the numerous small crystals detrained from convective updrafts do not persist in the anvil cirrus sampled during TC ]4.
Vallée, Isabelle; Macé, Pauline; Forbes, Lorry; Scandrett, Brad; Durand, Benoit; Gajadhar, Alvin; Boireau, Pascal
2007-07-01
Routine diagnosis of animal trichinellosis for food safety and trade relies on a method of artificial digestion to free Trichinella muscle larvae from meat for subsequent identification by microscopy. As part of a quality control system, the French National Reference Laboratory (NRL) initiated ring trials to determine the sensitivity of the test performed in the 72 routine diagnostic laboratories in France. A method was devised to obtain calibrated meat samples containing known numbers of capsules with Trichinella spiralis muscle larvae. This method was based on an incomplete artificial digestion of Trichinella-infected mice carcasses to allow the collection of intact Trichinella capsules. Capsules were placed into a meatball of 100 +/- 2 g of pork and horsemeat to produce proficiency samples. Three categories of samples were prepared: small (3 to 5 capsules), medium (7 to 10), and large (12 to 15). The sensitivity was expressed as the percentage of muscle larvae recovered from each proficiency sample. Reproducibility was tested with ring trials organized between two NRLs (France and Canada), and a reference sensitivity of 84.9% was established. National ring trials were then organized in France, with the 72 routine diagnostic laboratories each receiving four proficiency samples per session. After five sessions, an improvement in the digest test sensitivity was observed. Results at the fifth session indicated sensitivities of 78.60% +/- 23.70%, 81.19% +/- 19.59%, and 80.52% +/- 14.71% muscle larvae for small, medium, and large samples, respectively. This study supports the use of proficiency samples to accurately evaluate the performance of routine diagnostic laboratories that conduct digestion tests for animal trichinellosis diagnosis.
Cupisti, Adamasco; Benini, Omar; Ferretti, Valerio; Gianfaldoni, Daniela; Kalantar-Zadeh, Kamyar
2012-11-01
Assessment of the quantity and chemical type of phosphorus (P) content in cooked ham products with or without preservatives using a novel biochemical procedure. We examined the quantity and types of P in 40 samples of cooked ham, including 20 without and 20 with P-containing preservatives, which were purchased randomly from a grocery store in Italy. Food samples were analyzed for dry matter, nitrogen, fat, and P content. Novel spectrophotometric methods were used to measure total P and 3 different P subtypes, that is, water-soluble (inorganic) P including added preservatives and natural P derived from phospholipids and phosphoproteins, separately. Compared with hams without preservatives, hams with P-containing preservatives had significantly lower dry matter and protein and fat contents. There was 66% more inorganic P (IP) in ham with preservatives than in samples without preservatives (169 ± 36 vs. 102 ± 16 mg/100 g, P < .001, respectively). There were no significant differences in P contents derived from proteins or lipids. The P-to-protein ratio was higher in ham samples with preservatives than in those without preservatives (16.1 ± 4.0 and 9.8 ± 0.8 mg/g, P < .001). The sum of measured IP and P from phospholipids and phosphoproteins was 91% ± 4% of measured total P (207.1 ± 50.7 vs. 227.2 ± 54.4 mg/100 g), indicating a small portion of unspecified P and/or under measurement. Novel differential dietary P measurement detects added P-containing preservatives. Cooked ham with preservatives has 66% more measurable IP and 64% higher P-to-protein ratio than ham without preservatives. The contribution of food added with P-containing preservatives to global dietary P burden can negatively influence chronic kidney disease outcome and counteract the efficacy of P-binder medications: this is an important topic that warrants additional investigations. Copyright © 2012 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Additional nuclear criticality safety calculations for small-diameter containers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hone, M.J.
This report documents additional criticality safety analysis calculations for small diameter containers, which were originally documented in Reference 1. The results in Reference 1 indicated that some of the small diameter containers did not meet the criteria established for criticality safety at the Portsmouth facility (K{sub eff} +2{sigma}<.95) when modeled under various contingency assumptions of reflection and moderation. The calculations performed in this report reexamine those cases which did not meet the criticality safety criteria. In some cases, unnecessary conservatism is removed, and in other cases mass or assay limits are established for use with the respective containers.
The future of Stardust science
NASA Astrophysics Data System (ADS)
Westphal, A. J.; Bridges, J. C.; Brownlee, D. E.; Butterworth, A. L.; de Gregorio, B. T.; Dominguez, G.; Flynn, G. J.; Gainsforth, Z.; Ishii, H. A.; Joswiak, D.; Nittler, L. R.; Ogliore, R. C.; Palma, R.; Pepin, R. O.; Stephan, T.; Zolensky, M. E.
2017-09-01
Recent observations indicate that >99% of the small bodies in the solar system reside in its outer reaches—in the Kuiper Belt and Oort Cloud. Kuiper Belt bodies are probably the best-preserved representatives of the icy planetesimals that dominated the bulk of the solid mass in the early solar system. They likely contain preserved materials inherited from the protosolar cloud, held in cryogenic storage since the formation of the solar system. Despite their importance, they are relatively underrepresented in our extraterrestrial sample collections by many orders of magnitude ( 1013 by mass) as compared with the asteroids, represented by meteorites, which are composed of materials that have generally been strongly altered by thermal and aqueous processes. We have only begun to scratch the surface in understanding Kuiper Belt objects, but it is already clear that the very limited samples of them that we have in our laboratories hold the promise of dramatically expanding our understanding of the formation of the solar system. Stardust returned the first samples from a known small solar system body, the Jupiter-family comet 81P/Wild 2, and, in a separate collector, the first solid samples from the local interstellar medium. The first decade of Stardust research resulted in more than 142 peer-reviewed publications, including 15 papers in Science. Analyses of these amazing samples continue to yield unexpected discoveries and to raise new questions about the history of the early solar system. We identify nine high-priority scientific objectives for future Stardust analyses that address important unsolved problems in planetary science.
Best, Stephen P; Levina, Aviva; Glover, Chris; Johannessen, Bernt; Kappen, Peter; Lay, Peter A
2016-05-01
The design and operation of a low-volume spectroelectrochemical cell for X-ray absorption spectroscopy (XAS) of solutions at room temperature is described. Fluorescence XAS measurements are obtained from samples contained in the void space of a 50 µL reticulated vitreous carbon (sponge) working electrode. Both rapid electrosynthesis and control of the effects of photoreduction are achieved by control over the flow properties of the solution through the working electrode, where a good balance between the rate of consumption of sample and the minimization of decomposition was obtained by pulsing the flow of the solution by 1-2 µL with duty cycle of ∼3 s while maintaining a small net flow rate (26-100 µL h(-1)). The performance of the cell in terms of control of the redox state of the sample and minimization of the effects of photoreduction was demonstrated by XAS measurements of aqueous solutions of the photosensitive Fe(III) species, [Fe(C2O4)3](3-), together with that of the electrogenerated [Fe(C2O4)3](4-) product. The current response from the cell during the collection of XAS spectra provides an independent measure of the stability of the sample of the measurement. The suitability of the approach for the study of small volumes of mM concentrations of protein samples was demonstrated by the measurement of the oxidized and electrochemically reduced forms of cytochrome c.
Investigation of statistical parameters of the evolving wind wave field using a laser slope gauge
NASA Astrophysics Data System (ADS)
Zavadsky, A.; Shemer, L.
2017-05-01
Statistical parameters of water waves generated by wind in a small scale facility are studied using extensively a Laser Slope Gauge (LSG), in addition to conventional measuring instruments such as a wave gauge and Pitot tube. The LSG enables direct measurements of two components of the instantaneous surface slope. Long sampling duration in a relatively small experimental facility allowed accumulating records of the measured parameters containing a large number of waves. Data were accumulated for a range of wind velocities at multiple fetches. Frequency spectra of the surface elevation and of the instantaneous local slope variation measured under identical conditions are compared. Higher moments of the surface slope are presented. Information on the waves' asymmetry is retrieved from the computed skewness of the surface slope components.
A 2dF survey of the Small Magellanic Cloud
NASA Astrophysics Data System (ADS)
Evans, Christopher J.; Howarth, Ian D.; Irwin, Michael J.; Burnley, Adam W.; Harries, Timothy J.
2004-09-01
We present a catalogue of new spectral types for hot, luminous stars in the Small Magellanic Cloud (SMC). The catalogue contains 4161 objects, giving an order-of-magnitude increase in the number of SMC stars with published spectroscopic classifications. The targets are primarily B- and A-type stars (2862 and 853 objects respectively), with one Wolf-Rayet, 139 O-type and 306 FG stars, sampling the main sequence to ~mid-B. The selection and classification criteria are described, and objects of particular interest are discussed, including UV-selected targets from the Ultraviolet Imaging Telescope (UIT) experiment, Be and B[e] stars, `anomalous A supergiants' and composite-spectrum systems. We examine the incidence of Balmer-line emission, and the relationship between Hγ equivalent width and absolute magnitude for BA stars.
NASA Astrophysics Data System (ADS)
Zhao, Weihua; Li, Qingyun; Guo, Weijie; Wang, Zhenhua
2017-05-01
This study take Nahan River as a case to research the impacts of small hydropower stations on macroinvertebrates community. Results showed that a total of 13 macroinvertebrate samples was collected and contained 56 taxa belonging to 18 families and 35 genera. The influence of runoff regulation was more seriously than hydrological period. There were obvious zoning phenomenon of macroinvertebrates between reservoir, downdam reaches and natural reaches. From reservoir, downdam reaches to natural reaches, species abundance increased in turn. There are the least species in reservoir, the most in natural rivers. The reservoirs had the highest biomass and were quite different from those in downdam and natural reaches. However, there was no significant difference between different periods of hydropower station.
NASA Technical Reports Server (NTRS)
Tsuchiyama, A.; Ebihara, M.; Kimura, M.; Kitajima, F.; Kotsugi, M.; Ito, S.; Nagao, K.; Nakamura, T.; Naraoka, H.; Noguchi, T.;
2011-01-01
The Hayabusa spacecraft arrived at S-type Asteroid 25143 Itokawa in November 2006, and reveal astounding features of the small asteroid (535 x 294 x 209 m). Near-infrared spectral shape indicates that the surface of this body has an olivinerich mineral assemblage potentially similar to that of LL5 or LL6 chondrites with different degrees of space weathering. Based on the surface morphological features observed in high-resolution images of Itokawa s surface, two major types of boulders were distinguished: rounded and angular boulders. Rounded boulders seem to be breccias, while angular boulders seem to have severe impact origin. Although the sample collection did not be made by normal operations, it was considered that some amount of samples, probably small particles of regolith, was collected from MUSES-C regio on the Itokawa s surface. The sample capsule was successfully recovered on the earth on June 13, 2010, and was opened at curation facility of JAXA (Japan Aerospace Exploration Agency), Sagamihara, Japan. A large number of small particles were found in the sample container. Preliminary analysis with SEM/EDX at the curation facility showed that at least more than 1500 grains were identified as rocky particles, and most of them were judged to be of extraterrestrial origin, and definitely from Asteroid Itokawa. Minerals (olivine, low-Ca pyroxene, high-Ca pyroxene, plagioclase, Fe sulfide, Fe-Ni metal, chromite, Ca phosphate), roughly estimated mode the minerals and rough measurement of the chemical compositions of the silicates show that these particles are roughly similar to LL chondrites. Although their size are mostly less than 10 m, some larger particles of about 100 m or larger were also identified. A part of the sample (probably several tens particles) will be selected by Hayabusa sample curation team and examined preliminary in Japan within one year after the sample recovery in prior to detailed analysis phase. Hayabusa Asteroidal Sample Preliminary Examination Team (HASPET) has been preparing for the preliminary examination with close cooperation with the curation team.
NASA Astrophysics Data System (ADS)
Hanke, Ulrich M.; McIntyre, Cameron P.; Schmidt, Michael W. I.; Wacker, Lukas; Eglinton, Timothy I.
2016-04-01
Measurements of the natural abundance of radiocarbon (14C) concentrations in inorganic and organic carbon-containing materials can be used to investigate their date of origin. Particularly, the biogeochemical cycling of specific compounds in the environment may be investigated applying molecular marker analyses. However, the isolation of specific molecules from environmental matrices requires a complex processing procedure resulting in small sample sizes that often contain less than 30 μg C. Such small samples are sensitive to extraneous carbon (Cex) that is introduced during the purification of the compounds (Shah and Pearson, 2007). We present a thorough radiocarbon blank assessment for benzene polycarboxylic acids (BPCA), a proxy for combustion products that are formed during the oxidative degradation of condensed polyaromatic structures (Wiedemeier et al, in press). The extraneous carbon assessment includes reference material for (1) chemical extraction, (2) preparative liquid chromatography (3) wet chemical oxidation which are subsequently measured with gas ion source AMS (Accelerator Mass Spectrometer, 5-100 μg C). We always use pairs of reference materials, radiocarbon depleted (14Cfossil) and modern (14Cmodern) to determine the fraction modern (F14C) of Cex.Our results include detailed information about the quantification of Cex in radiocarbon molecular marker analysis using BPCA. Error propagation calculations indicate that ultra-microscale samples (20-30 μg) are feasible with uncertainties of less than 10 %. Calculations of the constant contamination reveal important information about the source (F14C) and mass (μg) of Cex (Wacker and Christl, 2011) for each sub procedure. An external correction of compound specific radiocarbon data is essential for robust results that allow for a high degree of confidence in the 14C results. References Shah and Pearson, 2007. Ultra-microscale (5-25μg C) analysis of individual lipids by 14C AMS: Assessment and correction for sample processing blanks. Radiocarbon 49(1), 69-82. Wacker, L. and M. Christl. 2011. Data reduction for small radiocarbon samples - error propagation using the model of constant contamination. Ion Beam Physics, ETH Zurich, Annual report 2011. Wiedemeier, D.B., S.Q. Lang, M. Gierga, S. Abiven, S.M. Bernasconi, G.L. Bernasconi-Green, I. Hajdas, U.M. Hanke, M.D. Hilf, C.P. McIntyre, M.P.W. Schneider, R.H. Smittenberg, L. Wacker, G.L.B. Wiesenberg, M.W.I. Schmidt. Characterization, quantification and compound-specific isotopic analysis of pyrogenic carbon using benzene polycarboxylic acids (BPCA). Journal of Visualized Experiments. In press.
Distribution of circular proteins in plants: large-scale mapping of cyclotides in the Violaceae.
Burman, Robert; Yeshak, Mariamawit Y; Larsson, Sonny; Craik, David J; Rosengren, K Johan; Göransson, Ulf
2015-01-01
During the last decade there has been increasing interest in small circular proteins found in plants of the violet family (Violaceae). These so-called cyclotides consist of a circular chain of approximately 30 amino acids, including six cysteines forming three disulfide bonds, arranged in a cyclic cystine knot (CCK) motif. In this study we map the occurrence and distribution of cyclotides throughout the Violaceae. Plant material was obtained from herbarium sheets containing samples up to 200 years of age. Even the oldest specimens contained cyclotides in the preserved leaves, with no degradation products observable, confirming their place as one of the most stable proteins in nature. Over 200 samples covering 17 of the 23-31 genera in Violaceae were analyzed, and cyclotides were positively identified in 150 species. Each species contained a unique set of between one and 25 cyclotides, with many exclusive to individual plant species. We estimate the number of different cyclotides in the Violaceae to be 5000-25,000, and propose that cyclotides are ubiquitous among all Violaceae species. Twelve new cyclotides from six phylogenetically dispersed genera were sequenced. Furthermore, the first glycosylated derivatives of cyclotides were identified and characterized, further increasing the diversity and complexity of this unique protein family.
A USANS/SANS study of the accessibility of pores in the Barnett Shale to methane and water
Ruppert, Leslie F.; Sakurovs, Richard; Blach, Tomasz P.; He, Lilin; Melnichenko, Yuri B.; Mildner, David F.; Alcantar-Lopez, Leo
2013-01-01
Shale is an increasingly important source of natural gas in the United States. The gas is held in fine pores that need to be accessed by horizontal drilling and hydrofracturing techniques. Understanding the nature of the pores may provide clues to making gas extraction more efficient. We have investigated two Mississippian Barnett Shale samples, combining small-angle neutron scattering (SANS) and ultrasmall-angle neutron scattering (USANS) to determine the pore size distribution of the shale over the size range 10 nm to 10 μm. By adding deuterated methane (CD4) and, separately, deuterated water (D2O) to the shale, we have identified the fraction of pores that are accessible to these compounds over this size range. The total pore size distribution is essentially identical for the two samples. At pore sizes >250 nm, >85% of the pores in both samples are accessible to both CD4 and D2O. However, differences in accessibility to CD4 are observed in the smaller pore sizes (~25 nm). In one sample, CD4 penetrated the smallest pores as effectively as it did the larger ones. In the other sample, less than 70% of the smallest pores (4, but they were still largely penetrable by water, suggesting that small-scale heterogeneities in methane accessibility occur in the shale samples even though the total porosity does not differ. An additional study investigating the dependence of scattered intensity with pressure of CD4 allows for an accurate estimation of the pressure at which the scattered intensity is at a minimum. This study provides information about the composition of the material immediately surrounding the pores. Most of the accessible (open) pores in the 25 nm size range can be associated with either mineral matter or high reflectance organic material. However, a complementary scanning electron microscopy investigation shows that most of the pores in these shale samples are contained in the organic components. The neutron scattering results indicate that the pores are not equally proportioned in the different constituents within the shale. There is some indication from the SANS results that the composition of the pore-containing material varies with pore size; the pore size distribution associated with mineral matter is different from that associated with organic phases.
[Free crystalline silica: a comparison of methods for its determination in total dust].
Maciejewska, Aleksandra; Szadkowska-Stańczyk, Irena; Kondratowicz, Grzegorz
2005-01-01
The major objective of the study was to compare and investigate the usefulness of quantitative analyses of free crystalline silica (FCS) in the assessment of dust exposure in samples of total dust of varied composition, using three methods: chemical method in common use in Poland; infrared spectrometry; and x-ray powder diffraction. Mineral composition and FCS contents were investigated in 9 laboratory samples of raw materials, materials, and industrial wastes, containing from about 2 to over 80% of crystalline silica and reduced to particles of size corresponding with that of total dust. Sample components were identified using XRD and FT-IR methods. Ten independent determinations of FCS with each of the three study methods were performed in dust samples. An analysis of linear correlation was applied to investigate interrelationship between mean FCS determinations. In analyzed dust samples, along with silica dust there were numerous minerals interfering with silica during the quantitative analysis. Comparison of mean results of FCS determinations showed that the results obtained using the FT-IR method were by 12-13% lower than those obtained with two other methods. However, the differences observed were within the limits of changeability of results associated with their precision and dependence on reference materials used. Assessment of occupational exposure to dusts containing crystalline silica can be performed on the basis of quantitative analysis of FCS in total dusts using each of the compared methods. The FT-IR method is most appropriate for the FCS determination in samples of small amount of silica or collected at low dust concentrations; the XRD method for the analysis of multicomponent samples; and the chemical method in the case of medium and high FCS contents in samples or high concentrations of dusts in the work environment.
Chemical Data for Precipitate Samples
Foster, Andrea L.; Koski, Randolph A.
2008-01-01
During studies of sulfide oxidation in coastal areas of Prince William Sound in 2005, precipitate samples were collected from onshore and intertidal locations near the Ellamar, Threeman, and Beatson mine sites (chapter A, fig. 1; table 7). The precipitates include jarosite and amorphous Fe oxyhydroxide from Ellamar, amorphous Fe oxyhydroxide from Threeman, and amorphous Fe oxyhydroxide, ferrihydrite, and schwertmannite from Beatson. Precipitates occurring in the form of loose, flocculant coatings were harvested using a syringe and concentrated in the field by repetitive decanting. Thicker accumulations were either scraped gently from rocks using a stainless steel spatula or were scooped directly into receptacles (polyethylene jars or plastic heavy-duty zippered bags). Most precipitate samples contain small amounts of sedimentary detritus. With three jarosite-bearing samples from Ellamar, an attempt was made to separate the precipitate from the heavy-mineral fraction of the sediment. In this procedure, the sample was stirred in a graduated cylinder containing deionized water. The jarosite-rich suspension was decanted onto analytical filter paper and air dried before analysis. Eleven precipitate samples from the three mine sites were analyzed in laboratories of the U.S. Geological Survey (USGS) in Denver, Colorado (table 8). Major and trace elements were determined by inductively coupled plasma-mass spectrometry following multiacid (HCl-HNO3-HClO4-HF) digestion (Briggs and Meier, 2002), except for mercury, which was analyzed by cold-vapor atomic absorption spectroscopy (Brown and others, 2002a). X-ray diffraction (XRD) analyses were performed on powdered samples (<200 mesh) by S. Sutley of the USGS. Additional details regarding sample preparation and detection limits are found in Taggert (2002). Discussions of the precipitate chemistry and associated microbial communities are presented in Koski and others (2008) and Foster and others (2008), respectively.
Isotropic-nematic phase transition in aqueous sepiolite suspensions.
Woolston, Phillip; van Duijneveldt, Jeroen S
2015-01-01
Aqueous suspensions of sepiolite clay rods in water tend to form gels on increase of concentration. Here it is shown how addition of a small amount (0.1% of the clay mass) of a common stabiliser for clay suspensions, sodium polyacrylate, can allow the observation of an isotropic-nematic liquid crystal phase transition. This transition was found to move to higher clay concentrations upon adding NaCl, with samples containing 10(-3) M salt or above only displaying a gel phase. Even samples that initially formed liquid crystals had a tendency to form gels after several weeks, possibly due to Mg(2+) ions leaching from the clay mineral. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
Fluidics cube for biosensor miniaturization
NASA Technical Reports Server (NTRS)
Dodson, J. M.; Feldstein, M. J.; Leatzow, D. M.; Flack, L. K.; Golden, J. P.; Ligler, F. S.
2001-01-01
To create a small, portable, fully automated biosensor, a compact means of fluid handling is required. We designed, manufactured, and tested a "fluidics cube" for such a purpose. This cube, made of thermoplastic, contains reservoirs and channels for liquid samples and reagents and operates without the use of any internal valves or meters; it is a passive fluid circuit that relies on pressure relief vents to control fluid movement. We demonstrate the ability of pressure relief vents to control fluid movement and show how to simply manufacture or modify the cube. Combined with the planar array biosensor developed at the Naval Research Laboratory, it brings us one step closer to realizing our goal of a handheld biosensor capable of analyzing multiple samples for multiple analytes.
Kurata, Shinya; Kanagawa, Takahiro; Yamada, Kazutaka; Torimura, Masaki; Yokomaku, Toyokazu; Kamagata, Yoichi; Kurane, Ryuichiro
2001-01-01
We have developed a simple method for the quantitative detection of specific DNA or RNA molecules based on the finding that BODIPY® FL fluorescence was quenched by its interaction with a uniquely positioned guanine. This approach makes use of an oligonucleotide probe or primer containing a BODIPY® FL-modified cytosine at its 5′-end. When such a probe was hybridized with a target DNA, its fluorescence was quenched by the guanine in the target, complementary to the modified cytosine, and the quench rate was proportional to the amount of target DNA. This widely applicable technique will be used directly with larger samples or in conjunction with the polymerase chain reaction to quantify small DNA samples. PMID:11239011
Jankowski, Stéphane; Currie-Fraser, Erica; Xu, Licen; Coffa, Jordy
2008-09-01
Annotated DNA samples that had been previously analyzed were tested using multiplex ligation-dependent probe amplification (MLPA) assays containing probes targeting BRCA1, BRCA2, and MMR (MLH1/MSH2 genes) and the 9p21 chromosomal region. MLPA polymerase chain reaction products were separated on a capillary electrophoresis platform, and the data were analyzed using GeneMapper v4.0 software (Applied Biosystems, Foster City, CA). After signal normalization, loci regions that had undergone deletions or duplications were identified using the GeneMapper Report Manager and verified using the DyeScale functionality. The results highlight an easy-to-use, optimal sample preparation and analysis workflow that can be used for both small- and large-scale studies.
NASA Astrophysics Data System (ADS)
Syrkov, A. G.; Kabirov, V. R.; Silivanov, M. O.
2017-07-01
For the first time the change of the water repellent properties of dispersed copper, modified using quaternary ammonium compounds on 24 h time scale in saturated water vapours was studied. Exponential time dependences of the water repellent properties of dispersed copper with adsopted QAC were derived and characterized. It was established that the samples modified in mixed and consistent modes by both modifiers reach the saturation state faster than others, due to the small number of hydrophilic centers on the surface of metals. The last conclusion was confirmed by the distribution spectra of centers of adsorption, which were obtained by the adsorption of acid-base indicators for more dispersed samples based on aluminum powder.
Mars Sample Return mission: Two alternate scenarios
NASA Technical Reports Server (NTRS)
1991-01-01
Two scenarios for accomplishing a Mars Sample Return mission are presented herein. Mission A is a low cost, low mass scenario, while Mission B is a high technology, high science alternative. Mission A begins with the launch of one Titan IV rocket with a Centaur G' upper stage. The Centaur performs the trans-Mars injection burn and is then released. The payload consists of two lander packages and the Orbital Transfer Vehicle, which is responsible for supporting the landers during launch and interplanetary cruise. After descending to the surface, the landers deploy small, local rovers to collect samples. Mission B starts with 4 Titan IV launches, used to place the parts of the Planetary Transfer Vehicle (PTV) into orbit. The fourth launch payload is able to move to assemble the entire vehicle by simple docking routines. Once complete, the PTV begins a low thrust trajectory out from low Earth orbit, through interplanetary space, and into low Martian orbit. It deploys a communication satellite into a 1/2 sol orbit and then releases the lander package at 500 km altitude. The lander package contains the lander, the Mars Ascent Vehicle (MAV), two lighter than air rovers (called Aereons), and one conventional land rover. The entire package is contained with a biconic aeroshell. After release from the PTV, the lander package descends to the surface, where all three rovers are released to collect samples and map the terrain.
Shear weakening for different lithologies observed at different saturation stages
NASA Astrophysics Data System (ADS)
Diethart-Jauk, Elisabeth; Gegenhuber, Nina
2018-01-01
For this study, samples from different lithologies ("Leitha"-limestone, "Dachstein"-limestone, "Haupt"-dolomite, "Bunt"-sandstone, Grey Berea sandstone, granite, quartzite and basalt) were selected. Samples were dried at 70 °C, respectively 105 °C and were saturated with brine. Mass, porosity, permeability, compressional and shear wave velocity were determined from dry and brine saturated samples at laboratory conditions, based on an individual measurement program. Shear modulus was calculated to find out, if shear weakening exists for the dataset. Shear weakening means that shear modulus of dry samples is higher than of saturated samples, but it is assumed that shear modulus is unaffected by saturation. "Dachstein"-limestone and basalt show shear weakening, quartzite samples show both weakening and hardening. Granite samples are affected by temperature, after drying with 105 °C no change can be observed anymore. "Bunt"-sandstone samples show a change in the shear modulus in a small extent, although they may contain clay minerals. The other lithologies show no effect. Explanations for carbonate samples can be the complicated pore structure, for basalt it could be that weathering creates clay minerals which are known as causes for a change of the shear modulus. Fluid viscosity can also be an important factor.
Zinc and copper mineralization of the Vazante area, Minas Gerais, Brazil
Moore, Samuel L.
1956-01-01
A large body of zinc and copper mineralization is exposed in a line of low hills about 5 kilometers east of the small village of Vazante in the northwestern part of the state of Minas Gerais, Brazil. The Vazante area can be reached by roads leading north from the State of Sao Paulo, via Araxa; west from Balo Horizonte, Minas Gerais; and south from Paracatu, Minas Gerais. The deposit is in branching, sub-parallel fault breccia zones. Calamine (H2Zn2SiO5), and willomite (ZnSiO4), along with small quantities of smithsonite (ZnCO3), form the matrix of the fault breccia. The zinc mineralization is cut by narrow veins of chalcocite in platy crystal aggregate thought to be pseudomorphous after covellite. The chalcocite veins contain small quantities of sphalterite, galena, covellite and calamine. Faults that contain breccia zones displace shale and dolomite. The sedimentary rocks are thought to be Silurian in age. The fault breccia zones have a regional trend of N 40 degrees E and crop out over a strike length of more than four kilometers. The mineralization of the fault zones was observed to continue to the north for an additional four kilometers. The mineralized fault breccia zones range from a few meters to 60 meters in width. A large ore body is indicated that from available samples may average 35 percent zinc.
Lee, Kyung-Min; Herrman, Timothy J; Post, Lynn
2016-09-01
This article contains the results of the evaluation of distillers grain (DG) coproducts from different ethanol plants around the United States and supplemented in animal diets in Texas, based on samples analyzed from 2008 to 2014. The samples were assessed for concentration, occurrence, and prevalence of selected nutrients and contaminants. Protein and sulfur contents of DG were largely different between maize and sorghum coproducts, as well as wet distillers grain with solubles (WDGS) and dried distillers grain with solubles (DDGS), indicating a significant effect of grain feedstock and dry grind process stream on DG composition and quality. Salmonella was isolated in 4 DDGS samples of a total of 157 DG samples, a percentage (2.5%) that is lower than the percentage of Salmonella -positive samples found in other feed samples analyzed during the same period. A small amount of virginiamycin residue was found in 24 maize DDGS, 1 maize WDGS, and 2 sorghum DDGS samples of 242 samples in total. One sorghum DDGS sample of 168 DG samples was contaminated with animal protein prohibited for use in ruminant feed and was channeled to poultry feed. The concentrations of aflatoxin and fumonisin DG coproducts averaged 3.4 μg/kg and 0.7 mg/kg, respectively. Among contaminated maize DG samples, five DDGS samples for aflatoxin contained a higher concentration than the U.S. Food and Drug Administration (FDA) minimum action level of 20 μg/kg for use in animal feed, whereas no sample for fumonisin was found above the action level of 5 mg/kg. The study provides the most current results involving DG coproducts and associated hazards that will assist development of food safety plans required by the FDA in their September 2015 rule titled "Current Good Manufacturing Practice Hazard Analysis and Risk Based Preventive Controls for Food for Animals."
Høiseth, Gudrun; Fjeld, Bente; Burns, Margrete Larsen; Strand, Dag Helge; Vindenes, Vigdis
2014-06-01
Stability of drugs during storage is important in forensic toxicology. For the analytes detected after intake of heroin (6-acetylmorphine (6-AM), morphine and codeine), long-time stability in real life whole blood samples are studied in only a small number of cases. Whole blood post mortem (n=37) and whole blood samples from living persons (n=22) containing morphine and codeine as well as 6-AM in blood or urine were selected. All cases represented intake of heroin. All samples contained fluoride and were initially analysed and stored in normal conditions (-20°C) for 4-9 years. All samples were then reanalysed using the same analytical methods and the results were compared. For samples from living persons, the median change in concentration was -3.7% for morphine and -5.3% for codeine. For post mortem samples, the median change in concentration was -12% for morphine and -11% for codeine. Both for samples from living persons and post mortem samples, the decrease in the concentrations from the original analysis to reanalysis were statistically significant for morphine and codeine. Regarding 6-AM, all living samples were negative at reanalysis. For post mortem samples, four cases still tested positive for 6-AM at reanalysis with a median change in the concentrations of -81%. There was no significant change in the morphine to codeine concentration ratios neither for living nor post mortem samples. This study showed that in real life whole blood samples, the concentrations of morphine and codeine are relatively stable during long-term storage at -20°C. 6-AM on the other hand, shows a considerable decrease in concentrations that is important to consider when interpreting results from reanalyses of forensic cases. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
S. Dong; N. Paterson; S.G. Kazarian
A suite of tuyere-level coke samples have been withdrawn from a working blast furnace during coal injection, using the core-drilling technique. The samples have been characterized by size exclusion chromatography (SEC), Fourier transform Raman spectroscopy (FT-RS), and X-ray powder diffraction (XRD) spectroscopy. The 1-methyl-2-pyrrolidinone (NMP) extracts of the cokes sampled from the 'bosh', the rear of the 'bird's nest', and the 'dead man' zones were found by SEC to contain heavy soot-like materials (ca. 10{sup 7}-10{sup 8} apparent mass units). In contrast, NMP extracts of cokes taken from the raceway and the front of the 'bird's nest' only contained amore » small amount of material of relatively lower apparent molecular mass (up to ca. 10{sup 5} u). Since the feed coke contained no materials extractable by the present method, the soot-like materials are thought to have formed during the reactions of volatile matter released from the injectant coal, probably via dehydrogenation and repolymerization of the tars. The Raman spectra of the NMP-extracted core-drilled coke samples showed variations reflecting their temperature histories. Area ratios of D-band to G-band decreased as the exposure temperature increased, while intensity ratios of D to G band and those of 2D to G bands increased with temperature. The graphitic (G), defect (D), and random (R) fractions of the carbon structure of the cokes were also derived from the Raman spectra. The R fractions decreased with increasing temperature, whereas G fractions increased, while the D fractions showed a more complex variation with temperature. These data appear to give clues regarding the graphitization mechanism of tuyere-level cokes in the blast furnace. 41 refs., 9 figs., 6 tabs.« less
Shrestha, Rojeet; Hui, Shu-Ping; Imai, Hiromitsu; Hashimoto, Satoru; Uemura, Naoto; Takeda, Seiji; Fuda, Hirotoshi; Suzuki, Akira; Yamaguchi, Satoshi; Hirano, Ken-Ichi; Chiba, Hitoshi
2015-09-01
Capric acid (FA10:0, decanoic acid) is a medium-chain fatty acid abundant in tropical oils such as coconut oil, whereas small amounts are present in milk of goat, cow, and human. Orally ingested FA10:0 is transported to the liver and quickly burnt within it. Only few reports are available for FA10:0 concentrations in human plasma. Fasting (n = 5, male/female = 3/2, age 31 ± 9.3 years old) and non-fasting (n = 106, male/female = 44/62, age 21.9 ± 3.2 years old) blood samples were collected from apparently healthy Japanese volunteers. The total FA10:0 in the plasma were measured by high-performance liquid chromatography after derivatization with 2-nitrophenylhydrazine followed by UV detection. Inter and intra-assay coefficient of variation of FA10:0 assay at three different concentrations ranged in 1.7-3.9 and 1.3-5.4%, respectively, with an analytical recovery of 95.2-104.0%. FA10:0 concentration was below detection limit (0.1 µmol/L) in each fasting human plasma. FA10:0 was not detected in 50 (47.2%) of 106 non-fasting blood samples, while 29 (27.4%) plasma samples contained FA10:0 less than or equal to 0.5 µmol/L (0.4 ± 0.1), and 27 (25.5%) contained it at more than 0.5 µmol/L (0.9 ± 0.3). A half of the non-fasting plasma samples contained detectable FA10:0. This simple, precise, and accurate high-performance liquid chromatography method might be useful for monitoring plasma FA10:0 during medium-chain triglycerides therapy. © The Author(s) 2015.
Small RNA Deep Sequencing and the Effects of microRNA408 on Root Gravitropic Bending in Arabidopsis
NASA Astrophysics Data System (ADS)
Li, Huasheng; Lu, Jinying; Sun, Qiao; Chen, Yu; He, Dacheng; Liu, Min
2015-11-01
MicroRNA (miRNA) is a non-coding small RNA composed of 20 to 24 nucleotides that influences plant root development. This study analyzed the miRNA expression in Arabidopsis root tip cells using Illumina sequencing and real-time PCR before (sample 0) and 15 min after (sample 15) a 3-D clinostat rotational treatment was administered. After stimulation was performed, the expression levels of seven miRNA genes, including Arabidopsis miR160, miR161, miR394, miR402, miR403, miR408, and miR823, were significantly upregulated. Illumina sequencing results also revealed two novel miRNAsthat have not been previously reported, The target genes of these miRNAs included pentatricopeptide repeat-containing protein and diadenosine tetraphosphate hydrolase. An overexpression vector of Arabidopsis miR408 was constructed and transferred to Arabidopsis plant. The roots of plants over expressing miR408 exhibited a slower reorientation upon gravistimulation in comparison with those of wild-type. This result indicate that miR408 could play a role in root gravitropic response.
Adsorption of Water on Simulated Moon Dust Samples
NASA Technical Reports Server (NTRS)
Goering, John P.; Sah, Shweta; Burghaus, Uwe; Street, Kenneth W., Jr.
2008-01-01
A lunar regolith simulant dust sample (JSC-1a) supported on a silica wafer (SiO2/Si(111)) has been characterized by scanning electron microscopy (SEM), energy dispersive x-ray spectroscopy (EDX), and Auger electron spectroscopy (AES). The adsorption kinetics of water has been studied primarily by thermal desorption spectroscopy (TDS) and also by collecting isothermal adsorption transients. The support has been characterized by water TDS. JSC-1a consists mostly of aluminosilicate glass and other minerals containing Fe, Na, Ca, and Mg. The particle sizes span the range from a few microns up to 100 microns. At small exposures, H2O TDS is characterized by broad (100 to 450 K) structures; at large exposures distinct TDS peaks emerge that are assigned to amorphous solid water (145 K) and crystalline ice (165 K). Water dissociates on JSC-1a at small exposures but not on the bare silica support. It appears that rather porous condensed ice layers form at large exposures. At thermal impact energies, the initial adsorption probability amounts to 0.92+/-0.05.
McCrae, Robert R.; Scally, Matthew; Terracciano, Antonio; Abecasis, Gonçalo R.; Costa, Paul T.
2011-01-01
There is growing evidence that personality traits are affected by many genes, all of which have very small effects. As an alternative to the largely-unsuccessful search for individual polymorphisms associated with personality traits, we identified large sets of potentially related single nucleotide polymorphisms (SNPs) and summed them to form molecular personality scales (MPSs) with from 4 to 2,497 SNPs. Scales were derived from two-thirds of a large (N = 3,972) sample of individuals from Sardinia who completed the Revised NEO Personality Inventory and were assessed in a genome-wide association scan. When MPSs were correlated with the phenotype in the remaining third of the sample, very small but significant associations were found for four of the five personality factors when the longest scales were examined. These data suggest that MPSs for Neuroticism, Openness to Experience, Agreeableness, and Conscientiousness (but not Extraversion) contain genetic information that can be refined in future studies, and the procedures described here should be applicable to other quantitative traits. PMID:21114353
Enzyme-linked small-molecule detection using split aptamer ligation.
Sharma, Ashwani K; Kent, Alexandra D; Heemstra, Jennifer M
2012-07-17
Here we report an aptamer-based analogue of the widely used sandwich enzyme-linked immunosorbent assay (ELISA). This assay utilizes the cocaine split aptamer, which is comprised of two DNA strands that only assemble in the presence of the target small molecule. One split aptamer fragment is immobilized on a microplate, then a test sample is added containing the second split aptamer fragment. If cocaine is present in the test sample, it directs assembly of the split aptamer and promotes a chemical ligation between azide and cyclooctyne functional groups appended to the termini of the split aptamer fragments. Ligation results in covalent attachment of biotin to the microplate and provides a colorimetric output upon conjugation to streptavidin-horseradish peroxidase. Using this assay, we demonstrate detection of cocaine at concentrations of 100 nM-100 μM in buffer and 1-100 μM human blood serum. The detection limit of 1 μM in serum represents an improvement of two orders of magnitude over previously reported split aptamer-based sensors and highlights the utility of covalently trapping split aptamer assembly events.
Vacancy clustering and acceptor activation in nitrogen-implanted ZnO
NASA Astrophysics Data System (ADS)
Børseth, Thomas Moe; Tuomisto, Filip; Christensen, Jens S.; Monakhov, Edouard V.; Svensson, Bengt G.; Kuznetsov, Andrej Yu.
2008-01-01
The role of vacancy clustering and acceptor activation on resistivity evolution in N ion-implanted n -type hydrothermally grown bulk ZnO has been investigated by positron annihilation spectroscopy, resistivity measurements, and chemical profiling. Room temperature 220keV N implantation using doses in the low 1015cm-2 range induces small and big vacancy clusters containing at least 2 and 3-4 Zn vacancies, respectively. The small clusters are present already in as-implanted samples and remain stable up to 1000°C with no significant effect on the resistivity evolution. In contrast, formation of the big clusters at 600°C is associated with a significant increase in the free electron concentration attributed to gettering of amphoteric Li impurities by these clusters. Further annealing at 800°C results in a dramatic decrease in the free electron concentration correlated with activation of 1016-1017cm-3 acceptors likely to be N and/or Li related. The samples remain n type, however, and further annealing at 1000°C results in passivation of the acceptor states while the big clusters dissociate.
High-throughput liquid-absorption air-sampling apparatus and methods
Zaromb, Solomon
2000-01-01
A portable high-throughput liquid-absorption air sampler [PHTLAAS] has an asymmetric air inlet through which air is drawn upward by a small and light-weight centrifugal fan driven by a direct current motor that can be powered by a battery. The air inlet is so configured as to impart both rotational and downward components of motion to the sampled air near said inlet. The PHTLAAS comprises a glass tube of relatively small size through which air passes at a high rate in a swirling, highly turbulent motion, which facilitates rapid transfer of vapors and particulates to a liquid film covering the inner walls of the tube. The pressure drop through the glass tube is <10 cm of water, usually <5 cm of water. The sampler's collection efficiency is usually >20% for vapors or airborne particulates in the 2-3.mu. range and >50% for particles larger than 4.mu.. In conjunction with various analyzers, the PHTLAAS can serve to monitor a variety of hazardous or illicit airborne substances, such as lead-containing particulates, tritiated water vapor, biological aerosols, or traces of concealed drugs or explosives.
NASA Astrophysics Data System (ADS)
Karatay, Ahmet; Küçüköz, Betül; Pekdemir, Sami; Onses, Mustafa Serdar; Elmali, Ayhan
2017-11-01
We have investigated the plasmonic properties of heterostructures that consist of gold nanosphere (NSs) with average diameters of 60 nm, 40 nm and 20 nm on poly (ethylene glycol) (PEG) brushes by using ultrafast pump-probe spectroscopy experiments. Gold NSs start to behave like gold nanorods with increasing number of immobilization cycles due to the close proximity. Gold NSs immobilized by 3 and 5 deposition cycles show longitudinal modes of plasmon bands at long wavelengths which are characteristic behaviors for gold nanorods. Increasing the number of immobilization cycle also increase relaxation times of samples due to the close proximity. Linear absorption spectra and scanning electron microscopy images show that there are close packing assemblies for heterostructures containing 20 nm gold NSs as the small particle. Ultrafast electron transfer (<100 fs) occurs between transverse and longitudinal modes by exciting the samples at both 520 nm and 650 nm. Further, experimental results indicate that, heterostructures with the small particles have faster relaxation times than other heterostructures due to closed packing of 20 nm gold NSs.
Synthesis and properties of precipitated cobalt ferrite nanoparticles
NASA Astrophysics Data System (ADS)
Ristic, Mira; Krehula, Stjepko; Reissner, Michael; Jean, Malick; Hannoyer, Beatrice; Musić, Svetozar
2017-07-01
The formation and properties of cobalt ferrite were investigated with XRD, FT-IR, FE-SEM, Mössbauer and magnetometry. Cobalt ferrite samples were prepared (a) by combining coprecipitation Co(OH)2/2Fe(OH)3, using NaOH between pH 5.2 and 11.4 and autoclaving, and (b) by autoclaving the Co(OH)2/2Fe(OH)3 coprecipitate in a very strong alkaline medium. XRD and FE SEM showed that both CoFe2O4 crystallites and particles were in the nanosize range. The FT-IR spectra were typical of spinel ferrites. Cobalt ferrite precipitated at pH 7.2 and at 11.4 contained a small fraction of α-Fe2O3, whereas in the sample precipitated at pH 11.4 a very small amount (traces) of α-FeOOH were detected by FT-IR, additionally. Parameters obtained by Mössbauer spectroscopy suggested a structural migration of cobalt and iron ions in prepared cobalt ferrite spinels with the prolonged time of autoclaving. Magnetic measurements showed the magnetic behaviour typical of spinel ferrite nanoparticles.
Rare high-impact disease variants: properties and identifications.
Park, Leeyoung; Kim, Ju Han
2016-03-21
Although many genome-wide association studies have been performed, the identification of disease polymorphisms remains important. It is now suspected that many rare disease variants induce the association signal of common variants in linkage disequilibrium (LD). Based on recent development of genetic models, the current study provides explanations of the existence of rare variants with high impacts and common variants with low impacts. Disease variants are neither necessary nor sufficient due to gene-gene or gene-environment interactions. A new method was developed based on theoretical aspects to identify both rare and common disease variants by their genotypes. Common disease variants were identified with relatively small odds ratios and relatively small sample sizes, except for specific situations in which the disease variants were in strong LD with a variant with a higher frequency. Rare disease variants with small impacts were difficult to identify without increasing sample sizes; however, the method was reasonably accurate for rare disease variants with high impacts. For rare variants, dominant variants generally showed better Type II error rates than recessive variants; however, the trend was reversed for common variants. Type II error rates increased in gene regions containing more than two disease variants because the more common variant, rather than both disease variants, was usually identified. The proposed method would be useful for identifying common disease variants with small impacts and rare disease variants with large impacts when disease variants have the same effects on disease presentation.
Neon produced by solar cosmic rays in ordinary chondrites
NASA Astrophysics Data System (ADS)
Roth, Antoine S. G.; Trappitsch, Reto; Metzler, Knut; Hofmann, Beda A.; Leya, Ingo
2017-06-01
Solar-cosmic-ray-produced Ne (SCR-Ne), in the form of low cosmogenic 21Ne/22Ne ratios (21Ne/22Necos <0.8), is more likely to be found in rare meteorite classes, like Martian meteorites, than in ordinary chondrites. This may be the result of a sampling bias: SCR-Ne is better preserved in meteorites with small preatmospheric radii and these specimens are often only studied if they belong to unusual or rare classes. We measured He and Ne isotopic concentrations and nuclear tracks in 25 small unpaired ordinary chondrites from Oman. Most chondrites have been intensively heated during atmospheric entry as evidenced by the disturbed track records, the low 3He/21Ne ratios, the low 4He concentrations, and the high peak release temperatures. Concentration depth profiles indicate significant degassing; however, the Ne isotopes are mainly undisturbed. Remarkably, six chondrites have low 21Ne/22Necos in the range 0.711-0.805. Using a new physical model for the calculation of SCR production rates, we show that four of the chondrites contain up to 20% of SCR-Ne; they are analyzed in terms of preatmospheric sizes, cosmic ray exposure ages, mass ablation losses, and orbits. We conclude that SCR-Ne is preserved, regardless of the meteorite class, in specimens with small preatmospheric radii. Sampling bias explains the predominance of SCR-Ne in rare meteorites, although we cannot exclude that SCR-Ne is more common in Martian meteorites than it is in small ordinary chondrites.
Rosasco, G.J.; Roedder, E.
1979-01-01
Rosasco et al. (1975), reported the first successful application of laser-excited Raman spectroscopy for the identification and nondestructive partial analysis of individual solid, liquid, and gaseous phases in selected fluid inclusions. We report here the results of the application of a new instrument, based on back-scattering, that eliminates many of the previous stringent sample limitations and hence greatly expands the range of applicability of Raman spectroscopy to fluid inclusions. Fluid inclusions in many porphyry copper deposits contain 5-10 ??m 'daughter' crystals thought to be anhydrite but too small for identification by the previous Raman technique. Using the new instrument, we have verified that such daughter crystals in quartz from Bingham, Utah, are anhydrite. They may form by leakage of hydrogen causing internal autooxidation of sulfide ion. Daughter crystals were also examined in apatite (Durango, Mexico) and emerald (Muzo, Colombia). Valid analyses of sulfur species in solution in small fluid inclusions from ore deposits would be valuable, but are generally impossible by conventional methods. We present a calibration procedure for analyses for SO42- in such inclusions from Bingham, Utah (12,000 ?? 4000 ppm) and Creede, Colo. (probably < 500 ppm). A fetid Brazilian quartz, originally thought to contain liquid H2S, is shown to contain only HS- in major amounts. ?? 1979.
Nogueira, María Soledad; Decundo, Julieta; Martinez, Mauro; Dieguez, Susana Nelly; Moreyra, Federico; Moreno, Maria Virginia
2018-01-01
Two of the most common species of toxin-producing Fusarium contaminating small cereal grains are Fusarium graminearum and F. poae; with both elaborating diverse toxins, especially deoxynivalenol (DON) and nivalenol (NIV), respectively. The objective of our work during the 2012–2014 growing seasons was to screen crops for the most commonly isolated Fusarium species and to quantify DON and NIV toxins in natural malting-barley samples from different producing areas of Argentina. We identified 1180 Fusarium isolates in the 119 samples analyzed, with 51.2% being F. graminearum, 26.2% F. poae and 22.6% other species. We found high concentrations of mycotoxins, at maximum values of 12 μg/g of DON and 7.71 μg/g of NIV. Of the samples, 23% exhibited DON at an average of 2.36 μg/g, with 44% exceeding the maximum limits (average of 5.24 μg/g); 29% contained NIV at an average of 2.36 μg/g; 7% contained both DON and NIV; and 55% were without DON or NIV. Finally, we report the mycotoxin contamination of the grain samples produced by F. graminearum and F. poae, those being the most frequent Fusarium species present. We identified the main Fusarium species affecting natural malting-barley grains in Argentina and documented the presence of many samples with elevated concentrations of DON and NIV. To our knowledge, the investigation reported here was the first to quantify the contamination by Fusarium and its toxins in natural samples of malting barley in Argentina. PMID:29439459
Nogueira, María Soledad; Decundo, Julieta; Martinez, Mauro; Dieguez, Susana Nelly; Moreyra, Federico; Moreno, Maria Virginia; Stenglein, Sebastian Alberto
2018-02-11
Two of the most common species of toxin-producing Fusarium contaminating small cereal grains are Fusarium graminearum and F. poae ; with both elaborating diverse toxins, especially deoxynivalenol (DON) and nivalenol (NIV), respectively. The objective of our work during the 2012-2014 growing seasons was to screen crops for the most commonly isolated Fusarium species and to quantify DON and NIV toxins in natural malting-barley samples from different producing areas of Argentina. We identified 1180 Fusarium isolates in the 119 samples analyzed, with 51.2% being F. graminearum , 26.2% F. poae and 22.6% other species. We found high concentrations of mycotoxins, at maximum values of 12 μg/g of DON and 7.71 μg/g of NIV. Of the samples, 23% exhibited DON at an average of 2.36 μg/g, with 44% exceeding the maximum limits (average of 5.24 μg/g); 29% contained NIV at an average of 2.36 μg/g; 7% contained both DON and NIV; and 55% were without DON or NIV. Finally, we report the mycotoxin contamination of the grain samples produced by F. graminearum and F. poae , those being the most frequent Fusarium species present. We identified the main Fusarium species affecting natural malting-barley grains in Argentina and documented the presence of many samples with elevated concentrations of DON and NIV. To our knowledge, the investigation reported here was the first to quantify the contamination by Fusarium and its toxins in natural samples of malting barley in Argentina.
Simonin, P.W.; Limburg, K.E.; Machut, L.S.
2007-01-01
Adult blueback herring Alosa aestivalis (N = 116) were collected during the 1999, 2000, and 2002-2004 spawning runs from sites on the Hudson and Mohawk rivers, and gut contents were analyzed. Thirty-four fish (33% of those examined) were found to contain food material. Food items were present in 41% of Mohawk River samples and 11% of Hudson River samples; all Hudson River fish containing food were captured in small tributaries above the head of tide. Hudson River fish predominantly consumed zooplankton, while Mohawk River fish consumed benthic aquatic insects in large quantities, including Baetidae, Ephemeridae, and Chironomidae. Using stable isotope analysis and a mixing model, we found that fish collected later in the season had significantly decreased marine-derived C. Condition indices of later-season fish were equal to or greater than those of fish collected earlier in the season. Blueback herring in this system may face increased energy requirements as they migrate farther upstream during spawning runs, and feeding may provide energy subsidies needed to maintain fitness over their expanded migratory range. ?? Copyright by the American Fisheries Society 2007.
NASA Astrophysics Data System (ADS)
Song, Ho-Jun; Kim, Ji-Woo; Kook, Min-Suk; Moon, Won-Jin; Park, Yeong-Joon
2010-09-01
AC-type microarc oxidation (MAO) and hydrothermal treatment techniques were used to enhance the bioactivity of commercially pure titanium (CP-Ti). The porous TiO 2 layer fabricated by the MAO treatment had a dominant anatase structure and contained Ca and P ions. The MAO-treated specimens were treated hydrothermally to form HAp crystallites on the titanium oxide layer in an alkaline aqueous solution (OH-solution) or phosphorous-containing alkaline solution (POH-solution). A small number of micro-sized hydroxyapatite (HAp) crystallites and a thin layer composed of nano-sized HAps were formed on the Ti-MAO-OH group treated hydrothermally in an OH-solution, whereas a large number of micro-sized HAp crystallites and dense anatase TiO 2 nanorods were formed on the Ti-MAO-POH group treated hydrothermally in a POH-solution. The layer of bone-like apatite that formed on the surface of the POH-treated sample after soaking in a modified simulated body fluid was thicker than that on the OH-treated samples.
Hypoxanthine enhances the cured meat taste
Nakamura, Yukinobu; Yoshida, Yuka; Hattori, Akihito
2016-01-01
Abstract We evaluated the enhancement of cured meat taste during maturation by sensory analysis. We focused on the heat‐stable sarcoplasmic fraction (HSSF) to identify the factors related to cured meat taste. Because the dry matter of HSSF contained more than 30% nitrogen, nitrogen compounds such as free amino acids, small peptides and adenosine triphosphate‐related compounds seemed to be the important components of HSSF. The samples cured with HSSF for 2 h exhibited the same taste profile as ones cured without HSSF for 168 h. Therefore, the changes in the amount and fractions of nitrogen compounds were examined in HSSF during incubation from 0 to 168 h. The concentration of hypoxanthine (Hx) gradually increased, while inosine‐5′‐monophosphate decreased during the incubation. The samples cured with pickles containing various concentrations of Hx were subjected to sensory analysis. The addition of Hx, in a dose‐dependent fashion, enhanced cured meat taste by maturation for 2 h. It was concluded that Hx is essential for the enhancement of cured meat taste. PMID:27169902
Tretiach, M; Pittao, E; Crisafulli, P; Adamo, P
2011-01-15
The hypothesis that exposure environment and land use influence element accumulation and particulate size composition in transplants of Hypnum cupressiforme has been tested using moss-bags containing oven-devitalized material. The samples were exposed for three months in ten green sites and ten roadsides in two areas with different land use (A, residential; B, residential/industrial) in the Trieste conurbation (NE Italy). Observations by SEM and EDX-ray microanalysis revealed that particle density was smaller in samples exposed in A than in B, with prevalence of particles containing Al, Ca, Fe and Si, and in good accordance with the element contents measured by acid digestion and ICP-MS. Moss-bags were generally less contaminated in green sites than in roadsides, apparently due to the different enrichment in coarse particles. In both environments, however, the majority of entrapped particles (up to 98.2%) belongs in the inhalable, small size classes (≤PM(10)). The need for careful selection of the exposure sites during the phase of biomonitoring planning is discussed. Copyright © 2010 Elsevier B.V. All rights reserved.
Effects of Varying Proportions of Glass on Reflectance Spectra of HED Polymict Breccias
NASA Technical Reports Server (NTRS)
Buchanan, P. C.; Reddy, V; LeCorre, L.; Cloutis, E. A.; Mann, P.; Le, L.
2014-01-01
Some meteorites contain significant amounts of glass, which, in most cases, probably results from impact processes on parent bodies.. Yamato 82202 is an example of one of the unequilibrated eucrites that contains significant proportions of impact glass distributed as veins throughout the meteorite. In other cases, fragments of glass are distributed throughout polymict breccias. For example, the polymict eucrite EET 87509 contains rare angular fragments of devitrified glass. Proportions of glass in most of these meteorites and in lithic clasts within these meteorites may vary locally from small amounts (less than one percent) to much larger amounts (subequal proportions of glass and mineral material). For example, some fragments within the South African polymict eucrite Macibini contain approximately 50% glass. The presence of these variable proportions of meteorite glass confirm the increased recognition that impact processes played an important role in the histories of asteroidal bodies. This study attempts to quantify the effects of a glass component on reflectance spectra by analyzing in the laboratory mixtures of varying proportions of a well-characterized HED polymict breccia and glass derived by melting a bulk sample of that breccia.
Synthesis of nanocrystalline rare earth oxides by glycothermal method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hosokawa, Saburo; Iwamoto, Shinji; Inoue, Masashi
2008-11-03
The reaction of yttrium acetate hydrate in 1,2-propanediol at 300 deg. C yielded a product containing acetate groups and glycol moieties. From this product, Y{sub 2}O{sub 3} was directly crystallized at 400 deg. C without the formation of a carbonate oxide phase. The thus-obtained Y{sub 2}O{sub 3} samples had a small crystallite size (2.2 nm) and significantly large surface area (280 m{sup 2}/g). Other nanocrystalline rare earth (Gd-Yb) oxides were also obtained by this method.
Chemical Sensing Using Fiber Cavity Ring-Down Spectroscopy
Waechter, Helen; Litman, Jessica; Cheung, Adrienne H.; Barnes, Jack A.; Loock, Hans-Peter
2010-01-01
Waveguide-based cavity ring-down spectroscopy (CRD) can be used for quantitative measurements of chemical concentrations in small amounts of liquid, in gases or in films. The change in ring-down time can be correlated to analyte concentration when using fiber optic sensing elements that change their attenuation in dependence of either sample absorption or refractive index. Two types of fiber cavities, i.e., fiber loops and fiber strands containing reflective elements, are distinguished. Both types of cavities were coupled to a variety of chemical sensor elements, which are discussed and compared. PMID:22294895
Microfluidic ultrasonic particle separators with engineered node locations and geometries
Rose, Klint A.; Fisher, Karl A.; Wajda, Douglas A.; Mariella, Jr., Raymond P.; Bailey, Christopher; Dehlinger, Dietrich; Shusteff, Maxim; Jung, Byoungsok; Ness, Kevin D.
2016-04-26
An ultrasonic microfluidic system includes a separation channel for conveying a sample fluid containing small particles and large particles, flowing substantially parallel, adjacent to a recovery fluid, with which it is in contact. An acoustic transducer produces an ultrasound standing wave, that generates a pressure field having at least one node of minimum pressure amplitude. An acoustic extension structure is located proximate to said separation channel for positioning said acoustic node off center in said acoustic area and concentrating the large particles in said recovery fluid stream.
Microfluidic ultrasonic particle separators with engineered node locations and geometries
Rose, Klint A; Fisher, Karl A; Wajda, Douglas A; Mariella, Jr., Raymond P; Bailey, Christopher; Dehlinger, Dietrich; Shusteff, Maxim; Jung, Byoungsok; Ness, Kevin D
2015-03-31
An ultrasonic microfluidic system includes a separation channel for conveying a sample fluid containing small particles and large particles, flowing substantially parallel, adjacent to a recovery fluid, with which it is in contact. An acoustic transducer produces an ultrasound standing wave, that generates a pressure field having at least one node of minimum, pressure amplitude. An acoustic extension structure is located proximate to said separation channel for positioning said acoustic node off center in said acoustic area and concentrating the large particles in said recovery fluid stream.
Microfluidic ultrasonic particle separators with engineered node locations and geometries
Rose, Klint A; Fisher, Karl A; Wajda, Douglas A; Mariella, Jr., Raymond P; Bailey, Christoppher; Dehlinger, Dietrich; Shusteff, Maxim; Jung, Byoungsok; Ness, Kevin D
2014-05-20
An ultrasonic microfluidic system includes a separation channel for conveying a sample fluid containing small particles and large particles, flowing substantially parallel, adjacent to a recovery fluid, with which it is in contact. An acoustic transducer produces an ultrasound standing wave, that generates a pressure field having at least one node of minimum pressure amplitude. An acoustic extension structure is located proximate to said separation channel for positioning said acoustic node off center in said acoustic area and concentrating the large particles in said recovery fluid stream.
Module Degradation Mechanisms Studied by a Multi-Scale Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnston, Steve; Al-Jassim, Mowafak; Hacke, Peter
2016-11-21
A key pathway to meeting the Department of Energy SunShot 2020 goals is to reduce financing costs by improving investor confidence through improved photovoltaic (PV) module reliability. A comprehensive approach to further understand and improve PV reliability includes characterization techniques and modeling from module to atomic scale. Imaging techniques, which include photoluminescence, electroluminescence, and lock-in thermography, are used to locate localized defects responsible for module degradation. Small area samples containing such defects are prepared using coring techniques and are then suitable and available for microscopic study and specific defect modeling and analysis.
Speedy milking of fresh venom from aculeate hymenopterans.
Fox, Eduardo G P; Xu, Meng; Wang, Lei; Chen, Li; Lu, Yong-Yue
2018-05-01
A straightforward method for extracting aculeate arthropod venoms by centrifugation is described, based on adapting a glass insert containing a piece of metal mesh or glass wool into a centrifuge tube. Venom apparatuses are centrifuged for 30 s intervals at ≈2000-6000 g, with samples being dislodged between cycles. Venom from fire ants, honeybees, and a social wasp were extracted within minutes. The method is suited for small-scale bioassays and allows for faithful descriptions of unmodified toxin cocktails. Copyright © 2018 Elsevier Ltd. All rights reserved.
Bray, Mark-Anthony; Gustafsdottir, Sigrun M; Rohban, Mohammad H; Singh, Shantanu; Ljosa, Vebjorn; Sokolnicki, Katherine L; Bittker, Joshua A; Bodycombe, Nicole E; Dančík, Vlado; Hasaka, Thomas P; Hon, Cindy S; Kemp, Melissa M; Li, Kejie; Walpita, Deepika; Wawer, Mathias J; Golub, Todd R; Schreiber, Stuart L; Clemons, Paul A; Shamji, Alykhan F
2017-01-01
Abstract Background Large-scale image sets acquired by automated microscopy of perturbed samples enable a detailed comparison of cell states induced by each perturbation, such as a small molecule from a diverse library. Highly multiplexed measurements of cellular morphology can be extracted from each image and subsequently mined for a number of applications. Findings This microscopy dataset includes 919 265 five-channel fields of view, representing 30 616 tested compounds, available at “The Cell Image Library” (CIL) repository. It also includes data files containing morphological features derived from each cell in each image, both at the single-cell level and population-averaged (i.e., per-well) level; the image analysis workflows that generated the morphological features are also provided. Quality-control metrics are provided as metadata, indicating fields of view that are out-of-focus or containing highly fluorescent material or debris. Lastly, chemical annotations are supplied for the compound treatments applied. Conclusions Because computational algorithms and methods for handling single-cell morphological measurements are not yet routine, the dataset serves as a useful resource for the wider scientific community applying morphological (image-based) profiling. The dataset can be mined for many purposes, including small-molecule library enrichment and chemical mechanism-of-action studies, such as target identification. Integration with genetically perturbed datasets could enable identification of small-molecule mimetics of particular disease- or gene-related phenotypes that could be useful as probes or potential starting points for development of future therapeutics. PMID:28327978
Hall, William L; Ramsey, Charles; Falls, J Harold
2014-01-01
Bulk blending of dry fertilizers is a common practice in the United States and around the world. This practice involves the mixing (either physically or volumetrically) of concentrated, high analysis raw materials. Blending is followed by bagging (for small volume application such as lawn and garden products), loading into truck transports, and spreading. The great majority of bulk blended products are not bagged but handled in bulk and transferred from the blender to a holding hopper. The product is then transferred to a transport vehicle, which may, or may not, also be a spreader. If the primary transport vehicle is not a spreader, then there is another transfer at the user site to a spreader for application. Segregation of materials that are mismatched due to size, density, or shape is an issue when attempting to effectively sample or evenly spread bulk blended products. This study, prepared in coordination with and supported by the Florida Department of Agriculture and Consumer Services and the Florida Fertilizer and Agrochemical Association, looks at the impact of varying particle size as it relates to blending, sampling, and application of bulk blends. The study addresses blends containing high ratios of N-P-K materials and varying (often small) quantities of the micronutrient Zn.
Thermal Stability of Otto Fuel Prepolymer
NASA Technical Reports Server (NTRS)
Tompa, Albert S.; Sandagger, Karrie H.; Bryant, William F., Jr.; McConnell, William T.; Lacot, Fernando; Carr, Walter A.
2000-01-01
Otto Fuel II contains a nitrate ester, plasticizer, and 2-NDPA as a stabilizer. Otto Fuel with stabilizers from three vendors was investigated by dynamic and isothermal DSC using samples sealed in a glass ampoule and by Isothermal Microcalorimetry (IMC) using 10 gram samples aged at 75 C for 35 days. DSC kinetics did not show differences between the stabilizer; the samples had an activation energy of 36.7 +/- 0.6 kcal/mol. However, IMC analysis was sensitive enough to detect small differences between the stabilizer, namely energy of interaction values of 7 to 14 Joules. DSC controlled cooling and heating at 5 C/min from 30 to -60 to 40 C experiments were similar and showed a crystallization peak at -48 +/- 1 C during cooling, and upon heating there was a glass transition temperature step at approx. -54 +/- 0.5 C and a melting peak at -28 +/- 0.4 C.
Thermal Stability of Otto Fuel Prepolymer
NASA Technical Reports Server (NTRS)
Tompa, Albert S.; Sandagger, Karrie H.; Bryant, William F., Jr.; McConnell, William T.; Lacot, Fernando; Carr, Walter A.
2000-01-01
Otto Fuel II contains a nitrate ester, plasticizer, and 2-NPDA as a stabilizer. Otto Fuel with stabilizers from three vendors was investigated by dynamic and isothermal differential scanning calorimetry (DSC) using samples sealed in a glass ampoule and by Isothermal Microcalorimetry (IMC) using 10 gram samples aged at 75 C for 35 days. DSC kinetics did not show differences between the stabilizer; the samples had an activation energy of 36.7 +/- 0.6 kcal/mol. However, IMC analysis was sensitive enough to detect small differences between the stabilizer, namely energy of interaction values of 7 to 14 Joules. DSC controlled cooling and heating at 5 C/min from 30 to -60 to 40 C experiments were similar and showed a crystallization peak at -48 +/- 1 C during cooling, and upon heating there was a glass transition temperature step at approx. -54 +/- 0.5 C and a melting peak at -28 +/- 0.4 C.
NASA Astrophysics Data System (ADS)
Carey, Elizabeth M.; Peters, Gregory H.; Choukroun, Mathieu; Chu, Lauren; Carpenter, Emma; Cohen, Brooklin; Panossian, Lara; Zhou, Yu Meng; Sarkissian, Ani; Moreland, Scott; Shiraishi, Lori R.; Backes, Paul; Zacny, Kris; Green, Jacklyn R.; Raymond, Carol
2017-11-01
Comets are icy remnants of the Solar System formation, and as such contain some of the most primitive volatiles and organic materials. Sampling the surface of a comet is a high priority for the New Frontiers program. Planetary simulants are crucial to the development of adequate in situ instruments and sample acquisition systems. A high-fidelity comet surface simulant has been developed to support hardware design and development for one Comet Surface Sample Return tool, the BiBlade Comet Sampler. Mechanical Porous Ambient Comet Simulants (MPACS) can be manufactured to cover a wide range of desired physical properties, such as density and cone penetration resistance, and exhibit a brittle fracture mode. The structure of the MPACS materials is an aggregated composite structure of weakly-bonded grains of very small size (diameter ≤ 40 μm) that are most relevant to the structure of the surface of a comet nucleus.
Isolation of nanoscale exosomes using viscoelastic effect
NASA Astrophysics Data System (ADS)
Hu, Guoqing; Liu, Chao
2017-11-01
Exosomes, molecular cargos secreted by almost all mammalian cells, are considered as promising biomarkers to identify many diseases including cancers. However, the small size of exosomes (30-200 nm) poses serious challenges on their isolation from the complex media containing a variety of extracellular vesicles (EVs) of different sizes, especially in small sample volumes. Here we develop a viscoelasticity-based microfluidic system to directly separate exosomes from cell culture media or serum in a continuous, size-dependent, and label-free manner. Using a small amount of biocompatible polymer as the additive into the media to control the viscoelastic forces exerted on EVs, we are able to achieve a high separation purity (>90%) and recovery (>80%) of exosomes. The size cutoff in viscoelasticity-based microfluidics can be easily controlled using different PEO concentrations. Based on this size-dependent viscoelastic separation strategy, we envision the handling of diverse nanoscale objects, such as gold nanoparticles, DNA origami structures, and quantum dots. This work was supported financially by National Natural Science Foundation of China (11572334, 91543125).
SMALL ANGLE SCATTERING OF X-RAYS BY PLASTICALLY DEFORMED SINGLE CRYSTALS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinson, W.H.; Smoluchowski, R.
1959-05-01
The small-angle scattering of x rays from single crystals of magnesium plastically deformed by simple shear was measured in the angular range of 4' to 5 deg . The crystals were subjected to both unidirectional and cyclic shear stresses applied along the STAl 1 2-bar 0! direction. Thin slices of the deformed single crystals were prepared using strainfree cutting and polishing techniques. The thin slices had orientations such that the slip direction was either parallel or perpendicular to the incident x-ray beam in order to observe any anisotropy in the scattering that might be due to dislocations. It was foundmore » that those samples which contained deformation twins within the irradiated volume produced rather large scattered intensity. This scattered intensity is interpreted as being due to double Bragg scattering. The scattered intensity from other specimens was attributed to surface scattering. No evidence for small angle scattering by dislocations was found. (auth)« less
NASA Astrophysics Data System (ADS)
Udalski, A.; Pietrzynski, G.; Szymanski, M.; Kubiak, M.; Zebrun, K.; Soszynski, I.; Szewczyk, O.; Wyrzykowski, L.
2003-06-01
The photometric data collected by OGLE-III during the 2001 and 2002 observational campaigns aiming at detection of planetary or low-luminosity object transits were corrected for small scale systematic effects using the data pipeline by Kruszewski and Semeniuk and searched again for low amplitude transits. Sixteen new objects with small transiting companions, additional to previously found samples, were discovered. Most of them are small amplitude cases which remained undetected in the original data. Several new objects seem to be very promising candidates for systems containing substellar objects: extrasolar planets or brown dwarfs. Those include OGLE-TR-122, OGLE-TR-125, OGLE-TR-130, OGLE-TR-131 and a few others. Those objects are particularly worth spectroscopic follow-up observations for radial velocity measurements and mass determination. With well known photometric orbit only a few RV measurements should allow to confirm their actual status. All photometric data of presented objects are available to the astronomical community from the OGLE Internet archive.
Acrylamide concentrations in potato crisps in Europe from 2002 to 2011
Powers, Stephen J.; Mottram, Donald S.; Curtis, Andrew; Halford, Nigel G.
2013-01-01
A dataset of manufacturers' measurements of acrylamide levels in 40,455 samples of fresh sliced potato crisps from 20 European countries for years 2002 to 2011 was compiled. This dataset is by far the largest ever compiled relating to acrylamide levels in potato crisps. Analysis of variance was applied to the data and showed a clear, significant downward trend for mean levels of acrylamide, from 763 ± 91.1 ng g−1 (parts per billion) in 2002 to 358 ± 2.5 ng g−1 in 2011; this was a decrease of 53% ± 13.5%. The yearly 95th quantile values were also subject to a clear downward trend. The effect of seasonality arising from the influence of potato storage on acrylamide levels was evident, with acrylamide in the first 6 months of the year being significantly higher than in the second 6 months. The proportion of samples containing acrylamide at a level above the indicative value of 1000 ng g−1 for potato crisps introduced by the European Commission in 2011 fell from 23.8% in 2002 to 3.2% in 2011. Nevertheless, even in 2011, a small proportion of samples still contained high levels of acrylamide, with 0.2% exceeding 2000 ng g−1. PMID:23822178
Digital Assays Part I: Partitioning Statistics and Digital PCR.
Basu, Amar S
2017-08-01
A digital assay is one in which the sample is partitioned into many small containers such that each partition contains a discrete number of biological entities (0, 1, 2, 3, …). A powerful technique in the biologist's toolkit, digital assays bring a new level of precision in quantifying nucleic acids, measuring proteins and their enzymatic activity, and probing single-cell genotypes and phenotypes. Part I of this review begins with the benefits and Poisson statistics of partitioning, including sources of error. The remainder focuses on digital PCR (dPCR) for quantification of nucleic acids. We discuss five commercial instruments that partition samples into physically isolated chambers (cdPCR) or droplet emulsions (ddPCR). We compare the strengths of dPCR (absolute quantitation, precision, and ability to detect rare or mutant targets) with those of its predecessor, quantitative real-time PCR (dynamic range, larger sample volumes, and throughput). Lastly, we describe several promising applications of dPCR, including copy number variation, quantitation of circulating tumor DNA and viral load, RNA/miRNA quantitation with reverse transcription dPCR, and library preparation for next-generation sequencing. This review is intended to give a broad perspective to scientists interested in adopting digital assays into their workflows. Part II focuses on digital protein and cell assays.
Rubrobacter-related bacteria associated with rosy discolouration of masonry and lime wall paintings.
Schabereiter-Gurtner, C; Piñar, G; Vybiral, D; Lubitz, W; Rölleke, S
2001-11-01
A molecular approach was chosen to analyse the correlation between bacterial colonisation and rosy discolouration of masonry and lime wall paintings of two historically important buildings in Austria and Germany. The applied molecular method included PCR amplification of genes encoding the small subunit rRNA of bacteria (16S rDNA), genetic fingerprinting by denaturing gradient gel electrophoresis (DGGE), construction of 16S rDNA clone libraries, and comparative phylogenetic sequence analyses. The bacterial community of one red-pigmented biofilm sampled in Herberstein (Austria) contained bacteria phylogenetically related to the genera Saccharopolyspora, Nocardioides, Pseudonocardia, Rubrobacter, and to a Kineococcus-like bacterium. The bacterial community of the second red-pigmented biofilm sampled in Herberstein contained bacteria related to Arthrobacter, Comamonas, and to Rubrobacter. Rubrobacter-related 16S rDNA sequences were the most abundant. In the red-pigmented biofilm sampled in Burggen (Germany), only Rubrobacter-related bacteria were identified. No Rubrobacter-related bacteria were detected in non-rosy biofilms. The majority of sequences (70%) obtained from the bacterial communities of the three investigated rosy biofilms were related to sequences of the genus Rubrobacter (red-pigmented bacteria), demonstrating a correlation between Rubrobacter-related bacteria and the phenomenon of rosy discolouration of masonry and lime wall paintings.
Estimating Divergence Parameters With Small Samples From a Large Number of Loci
Wang, Yong; Hey, Jody
2010-01-01
Most methods for studying divergence with gene flow rely upon data from many individuals at few loci. Such data can be useful for inferring recent population history but they are unlikely to contain sufficient information about older events. However, the growing availability of genome sequences suggests a different kind of sampling scheme, one that may be more suited to studying relatively ancient divergence. Data sets extracted from whole-genome alignments may represent very few individuals but contain a very large number of loci. To take advantage of such data we developed a new maximum-likelihood method for genomic data under the isolation-with-migration model. Unlike many coalescent-based likelihood methods, our method does not rely on Monte Carlo sampling of genealogies, but rather provides a precise calculation of the likelihood by numerical integration over all genealogies. We demonstrate that the method works well on simulated data sets. We also consider two models for accommodating mutation rate variation among loci and find that the model that treats mutation rates as random variables leads to better estimates. We applied the method to the divergence of Drosophila melanogaster and D. simulans and detected a low, but statistically significant, signal of gene flow from D. simulans to D. melanogaster. PMID:19917765
Acrylamide concentrations in potato crisps in Europe from 2002 to 2011.
Powers, Stephen J; Mottram, Donald S; Curtis, Andrew; Halford, Nigel G
2013-01-01
A dataset of manufacturers' measurements of acrylamide levels in 40,455 samples of fresh sliced potato crisps from 20 European countries for years 2002 to 2011 was compiled. This dataset is by far the largest ever compiled relating to acrylamide levels in potato crisps. Analysis of variance was applied to the data and showed a clear, significant downward trend for mean levels of acrylamide, from 763 ± 91.1 ng g⁻¹ (parts per billion) in 2002 to 358 ± 2.5 ng g⁻¹ in 2011; this was a decrease of 53% ± 13.5%. The yearly 95th quantile values were also subject to a clear downward trend. The effect of seasonality arising from the influence of potato storage on acrylamide levels was evident, with acrylamide in the first 6 months of the year being significantly higher than in the second 6 months. The proportion of samples containing acrylamide at a level above the indicative value of 1000 ng g⁻¹ for potato crisps introduced by the European Commission in 2011 fell from 23.8% in 2002 to 3.2% in 2011. Nevertheless, even in 2011, a small proportion of samples still contained high levels of acrylamide, with 0.2% exceeding 2000 ng g⁻¹.
Schillaci, Michael A; Schillaci, Mario E
2009-02-01
The use of small sample sizes in human and primate evolutionary research is commonplace. Estimating how well small samples represent the underlying population, however, is not commonplace. Because the accuracy of determinations of taxonomy, phylogeny, and evolutionary process are dependant upon how well the study sample represents the population of interest, characterizing the uncertainty, or potential error, associated with analyses of small sample sizes is essential. We present a method for estimating the probability that the sample mean is within a desired fraction of the standard deviation of the true mean using small (n<10) or very small (n < or = 5) sample sizes. This method can be used by researchers to determine post hoc the probability that their sample is a meaningful approximation of the population parameter. We tested the method using a large craniometric data set commonly used by researchers in the field. Given our results, we suggest that sample estimates of the population mean can be reasonable and meaningful even when based on small, and perhaps even very small, sample sizes.
NASA Technical Reports Server (NTRS)
Kring, David A.; Zurcher, Lukas; Horz, Freidrich; Mertzmann, Stanley A.
2004-01-01
Impact melts within complex impact craters are generally homogeneous, unless they differentiated, contain immiscible melt components, or were hydrothermally altered while cooling. The details of these processes, however, and their chemical consequences, are poorly understood. The best opportunity to unravel them may lie with the Chicxulub impact structure, because it is the world s most pristine (albeit buried) large impact crater. The Chicxulub Scientific Drilling Project recovered approx. 100 meters of impactites in a continuous core from the Yaxcopoil-1 (YAX-1) borehole. This dramatically increased the amount of melt available for analyses, which was previously limited to two small samples N17 and N19) recovered from the Yucatan-6 (Y-6) borehole and one sample (N10) recovered from the Chicxulub-1 (C-1) borehole. In this study, we describe the chemical compositions of six melt samples over an approx. 40 m section of the core and compare them to previous melt samples from the Y-6 and C-1 boreholes.
Plutonium release from Fukushima Daiichi fosters the need for more detailed investigations
NASA Astrophysics Data System (ADS)
Schneider, Stephanie; Walther, Clemens; Bister, Stefan; Schauer, Viktoria; Christl, Marcus; Synal, Hans-Arno; Shozugawa, Katsumi; Steinhauser, Georg
2013-10-01
The contamination of Japan after the Fukushima accident has been investigated mainly for volatile fission products, but only sparsely for actinides such as plutonium. Only small releases of actinides were estimated in Fukushima. Plutonium is still omnipresent in the environment from previous atmospheric nuclear weapons tests. We investigated soil and plants sampled at different hot spots in Japan, searching for reactor-borne plutonium using its isotopic ratio 240Pu/239Pu. By using accelerator mass spectrometry, we clearly demonstrated the release of Pu from the Fukushima Daiichi power plant: While most samples contained only the radionuclide signature of fallout plutonium, there is at least one vegetation sample whose isotope ratio (0.381 +/- 0.046) evidences that the Pu originates from a nuclear reactor (239+240Pu activity concentration 0.49 Bq/kg). Plutonium content and isotope ratios differ considerably even for very close sampling locations, e.g. the soil and the plants growing on it. This strong localization indicates a particulate Pu release, which is of high radiological risk if incorporated.
Evaluation of a Traffic Sign Detector by Synthetic Image Data for Advanced Driver Assistance Systems
NASA Astrophysics Data System (ADS)
Hanel, A.; Kreuzpaintner, D.; Stilla, U.
2018-05-01
Recently, several synthetic image datasets of street scenes have been published. These datasets contain various traffic signs and can therefore be used to train and test machine learning-based traffic sign detectors. In this contribution, selected datasets are compared regarding ther applicability for traffic sign detection. The comparison covers the process to produce the synthetic images and addresses the virtual worlds, needed to produce the synthetic images, and their environmental conditions. The comparison covers variations in the appearance of traffic signs and the labeling strategies used for the datasets, as well. A deep learning traffic sign detector is trained with multiple training datasets with different ratios between synthetic and real training samples to evaluate the synthetic SYNTHIA dataset. A test of the detector on real samples only has shown that an overall accuracy and ROC AUC of more than 95 % can be achieved for both a small rate of synthetic samples and a large rate of synthetic samples in the training dataset.
Li, Weiyong; Worosila, Gregory D
2005-05-13
This research note demonstrates the simultaneous quantitation of a pharmaceutical active ingredient and three excipients in a simulated powder blend containing acetaminophen, Prosolv and Crospovidone. An experimental design approach was used in generating a 5-level (%, w/w) calibration sample set that included 125 samples. The samples were prepared by weighing suitable amount of powders into separate 20-mL scintillation vials and were mixed manually. Partial least squares (PLS) regression was used in calibration model development. The models generated accurate results for quantitation of Crospovidone (at 5%, w/w) and magnesium stearate (at 0.5%, w/w). Further testing of the models demonstrated that the 2-level models were as effective as the 5-level ones, which reduced the calibration sample number to 50. The models had a small bias for quantitation of acetaminophen (at 30%, w/w) and Prosolv (at 64.5%, w/w) in the blend. The implication of the bias is discussed.
Yu, Qiang; Wei, Dingbang; Huo, Hongwei
2018-06-18
Given a set of t n-length DNA sequences, q satisfying 0 < q ≤ 1, and l and d satisfying 0 ≤ d < l < n, the quorum planted motif search (qPMS) finds l-length strings that occur in at least qt input sequences with up to d mismatches and is mainly used to locate transcription factor binding sites in DNA sequences. Existing qPMS algorithms have been able to efficiently process small standard datasets (e.g., t = 20 and n = 600), but they are too time consuming to process large DNA datasets, such as ChIP-seq datasets that contain thousands of sequences or more. We analyze the effects of t and q on the time performance of qPMS algorithms and find that a large t or a small q causes a longer computation time. Based on this information, we improve the time performance of existing qPMS algorithms by selecting a sample sequence set D' with a small t and a large q from the large input dataset D and then executing qPMS algorithms on D'. A sample sequence selection algorithm named SamSelect is proposed. The experimental results on both simulated and real data show (1) that SamSelect can select D' efficiently and (2) that the qPMS algorithms executed on D' can find implanted or real motifs in a significantly shorter time than when executed on D. We improve the ability of existing qPMS algorithms to process large DNA datasets from the perspective of selecting high-quality sample sequence sets so that the qPMS algorithms can find motifs in a short time in the selected sample sequence set D', rather than take an unfeasibly long time to search the original sequence set D. Our motif discovery method is an approximate algorithm.
Rashid, Goran M M; Duran-Pena, Maria Jesus; Rahmanpour, Rahman; Sapsford, Devin; Bugg, Timothy D H
2017-04-10
The aim of the study was to isolate bacterial lignin-degrading bacteria from municipal solid waste soil, and to investigate whether they could be used to delignify lignocellulose-containing soil, and enhance methane release. A set of 20 bacterial lignin degraders, including 11 new isolates from municipal solid waste soil, were tested for delignification and phenol release in soil containing 1% pine lignocellulose. A group of 7 strains were then tested for enhancement of gas release from soil containing 1% lignocellulose in small-scale column tests. Using an aerobic pre-treatment, aerobic strains such as Pseudomonas putida showed enhanced gas release from the treated sample, but four bacterial isolates showed 5-10 fold enhancement in gas release in an in situ experiment under microanaerobic conditions: Agrobacterium sp., Lysinibacillus sphaericus, Comamonas testosteroni, and Enterobacter sp.. The results show that facultative anaerobic bacterial lignin degraders found in landfill soil can be used for in situ delignification and enhanced gas release in soil containing lignocellulose. The study demonstrates the feasibility of using an in situ bacterial treatment to enhance gas release and resource recovery from landfill soil containing lignocellulosic waste. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
NEA Multi-Chamber Sample Return Container with Hermetic Sealing
NASA Technical Reports Server (NTRS)
Rafeek, Shaheed; Kong, Kin Yuen; Sadick, Shazad; Porter, Christopher C.
2000-01-01
A sample return container is being developed by Honeybee Robotics to receive samples from a derivative of the Champollion/ST4 Sample Acquisition and Transfer Mechanism or other samplers such as the 'Touch and Go' Surface Sampler (TGSS), and then hermetically seal the samples for a sample return mission. The container is enclosed in a phase change material (PCM) chamber to prevent phase change during return and re-entry to earth. This container is designed to operate passively with no motors and actuators. Using the rotation axis of the TGSS sampler for interfacing, transferring and sealing samples, the container consumes no electrical power and therefore minimizes sample temperature change. The circular container houses multiple isolated canisters, which will be sealed individually for samples acquired from different sites or depths. The TGSS based sampler indexes each canister to the sample transfer position, below the index interface for sample transfer. After sample transfer is completed, the sampler indexes a seal carrier, which lines up seals with the openings of the canisters. The sampler moves to the sealing interface and seals the sample canisters one by one. The sealing interface can be designed to work with C-seals, knife edge seals and cup seals. This sample return container is being developed by Honeybee Robotics in collaboration with the JPL Exploration Technology program. A breadboard system of the sample return container has been recently completed and tested. Additional information is contained in the original extended abstract.
Gräfe, Donina; Ehlers, Bernhard; Mäde, Dietrich; Ellerbroek, Lüppo; Seidler, Tassilo; Johne, Reimar
2017-01-16
Polyomaviruses are small, non-enveloped, circular double-stranded DNA viruses. Some polyomaviruses can induce tumors and cancer under certain circumstances. The bovine polyomaviruses (BPyV) 1-3 have been only scarcely analyzed so far. It was hypothesized that the consumption of beef meat containing polyomaviruses could contribute to the development of cancer in humans. In order to assess the distribution of the BPyV genome in meat from Germany, 101 beef muscle samples and 10 ground beef samples were analyzed here. A specific sample preparation method combined with or without rolling circle amplification (RCA), and BPyV-specific PCRs were developed and applied. BPyV-1 DNA was detected in 1/101 (1%) samples from beef meat and in 2/10 (20%) ground beef samples. BPyV-2 DNA was detected in 3/10 (30%) ground beef samples, whereas BPyV-3 was not detected in the samples. Application of RCA did not increase the detection rate in ground beef samples. Sequence analysis of the PCR products indicated the presence of BPyV-1, BPyV-2a and BPyV-2b. The whole genome of a BPyV-1 strain from ground beef meat showed 97.8% sequence identity to the BPyV-1 reference strain and that of a BPyV-2a strain from ground beef meet showed 99.9% sequence identity to strain 2aS11. It can be concluded that BPyV genomes can be frequently detected in ground beef samples, although higher sample numbers should be investigated in future to confirm this finding. Further studies should focus on the infectivity, tumorigenicity and heat resistance of the contained viruses in order to assess the risk of cancer induction through consumption of BPyVs present in beef products. Copyright © 2016 Elsevier B.V. All rights reserved.
MOUND LABORATORY MONTHLY PROGRESS REPORT FOR MARCH 1961
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eichelberger, J.F.
Adhesives. The effects obtained when diols and triols are used to cure Adiprene L-213 are discussed. Most of the formulations are very viscous and present difficulties in degassing operations. Ionium Project. Four plant samples having 1 ppm or more of Th/sup 2//sup 3//sup 0/ were analyzed for Th/sup 2//sup 3//sup 0/ in two different ways, one using HNO/sub 3/ digestion and the other using HClO/sub 4/ digestion. The difference between these two methods found for one sample is attributed to insolubility induced by calcining. Half Life of Radium-223. The decay of a purified Ra/sup 2//sup 2//sup 3/ sample was followedmore » by alpha counting for 109 days; the results indicate that a long-lived impurity may be the cause of the nonconvergence of the probable error in the resolution time range. Purification of a composite sample containing Ac/sup 2// sup 2//sup 7/ to give a source of Ra/sup 2//sup 2//sup 3/ is described. Determination of Coincidence Correction. The coincidence correction was determined for a proportional alpha counter with Pb/sup 2//sup 1//sup 1/, and the best resolution times and half lives are given. Plutonium Alloy Research. The density of liquid Ce was measured from 825 to 1000 deg C with the vacuum pycnometer method; the thermal coefficient of cubical expansion is found to be very small, 33 x 10/sup -//sup 6/ cm/sup 3// cm/sup 3// deg C, and the volume change of fusion is also estimated to be small, less than 0.5%. The viscosities of molten La and Pr were determined from their melting points up to 996 deg C. Qualitative tests were made to study the wetting properties of Pu alloys on Ta. Pure liquid Pu did not wet Ta surfaces, but a Fu--43 at.% Co alloy had improved wetting properties. Plutonium-bearing Glass Fibers. Leaching tests were made at room temperature on glass fibers containing 10 wt.% Pu oxide. Reaching in water, 0.1 N HCl, and 0.5 N HNO/sub 3/ for 2206, 2183, and 1363 hr, respectively, resulted in respective losses of 0.15, 0.24, and 0.65% of the Pu oxide from the fibers. Additional leaching data for glass fibers containing 15 wt.% Pu oxide indicate that the rate of dissolution of Fu oxide is not related to the concentration of the Pu oxide but to that of the alkali metal oxides in the glass. Preliminary results are presented for the tensile strengths of glass fibers containing 20 wt.% Pu oxide. (D.L.C.)« less
Chen, Tung-Sheng; Chang, Mu-Hsin; Kuo, Wei-Wen; Lin, Yueh-Min; Yeh, Yu-Lan; Day, Cecilia Hsuan; Lin, Chien-Chung; Tsai, Fuu-Jen; Tsai, Chang-Hai; Huang, Chih-Yang
2013-04-01
Statistical and clinical reports indicate that betel nut chewing is strongly associated with progression of oral cancer because some ingredients in betel nuts are potential cancer promoters, especially arecoline. Early diagnosis for cancer biomarkers is the best strategy for prevention of cancer progression. Several methods are suggested for investigating cancer biomarkers. Among these methods, gel-based proteomics approach is the most powerful and recommended tool for investigating biomarkers due to its high-throughput. However, this proteomics approach is not suitable for screening biomarkers with molecular weight under 10 KDa because of the characteristics of gel electrophoresis. This study investigated biomarkers with molecular weight under 10 KDa in rats with arecoline challenge. The centrifuging vials with membrane (10 KDa molecular weight cut-off) played a crucial role in this study. After centrifuging, the filtrate (containing compounds with molecular weight under 10 KDa) was collected and spotted on a sample plate for MALDI-TOF mass spectrometry analysis. Compared to control, three extra peaks (m/z values were 1553.1611, 1668.2097 and 1740.1832, respectively) were found in sera and two extra peaks were found in heart tissue samples (408.9719 and 524.9961, respectively). These small compounds should play important roles and may be potential biomarker candidates in rats with arecoline. This study successfully reports a mass-based method for investigating biomarker candidates with small molecular weight in different types of sample (including serum and tissue). In addition, this reported method is more time-efficient (1 working day) than gel-based proteomics approach (5~7 working days).
Radics, T; Kiss, C; Tar, I; Márton, I J
2003-02-01
Apical periodontitis is characterized by the presence of immunocompetent cells producing a wide variety of inflammatory mediators. Releasing cytokines with long-range action, such as interleukin-6 (IL-6) and granulocyte-macrophage colony-stimulating factor (GM-CSF), apical periodontitis may induce changes in remote organs of the host. This study quantified the levels of IL-6 and GM-CSF in symptomatic and asymptomatic human periradicular lesions. Lesions were also characterized by size and histologic findings. Tissue samples were homogenized and supernatants were assayed using an enzyme-linked immunosorbent assay (ELISA). Correlations between cytokine levels and characteristic features (as single variables) of the lesions were analysed. There was a trend for higher levels of IL-6 and GM-CSF in symptomatic than in asymptomatic lesions, but the difference was not significant. Levels also tended to be higher in large than in small lesions, in polymorphonuclear (PMN) cell-rich than in PMN cell-poor samples, and in epithelialized than in non-epithelialized lesions. Significantly higher levels of IL-6 (778.1 +/- 220.5 pg/microg) and GM-CSF (363.3 +/- 98.4 pg/microg) were found in samples coincidentally possessing symptomatic and epithelialized features than in asymptomatic, small, PMN cell-poor, non-epithelialized lesions (IL-6: 45.2 +/- 13.1 pg/microg and GM-CSF: 135.1 +/- 26.4 pg/microg). These results suggest that symptomatic lesions containing epithelial cells represent an immunologically active stage of apical periodontitis, whereas asymptomatic, small, PMN cell-poor, non-epithelialized lesions represent healing apical lesions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wasson, J.T.; Ouyang, Xinwei; Wang, Jianmin
1989-03-01
The authors report concentrations of 14 elements in the metal of 38 iron meteorites and a pallasite. The meteorites are classified based on these data and on structural observations. Three samples are paired with previously classified irons; thus, these additional 35 irons raise the number of well-classified, independent iron meteorites to 598. One Yamato iron contains 342 mg/g Ni, the second highest Ni content in an IAB iron after Oktibbeha County. Two small irons from Western Australia appear to be metal nodules from mesosiderites. Several of the new irons are from Antarctica. Of 24 independent irons from Antarctica, 8 aremore » ungrouped. The fraction, 0.333, is much higher than the fraction 0.161 among all 598 classified irons. Statistical tests show that it is highly improbably ({approximately}2.9% probability) that the Antarctic population is a random sample of the larger population. The difference is probably related to the fact that the median mass of Antarctic irons is about two orders of magnitude smaller than that of non-Antarctic irons. It is doubtful that the difference results from fragmentation patterns yielding different size distributions favoring smaller masses among ungrouped irons. More likely is the possibility that smaller meteoroids tend to sample a larger number of asteroidal source regions, perhaps because small meteoroids tend to have higher ejection velocities or because small meteoroids have random-walked a greater increment of orbital semimajor axis away from that of the parent body.« less
Design of a small personal air monitor and its application in aircraft.
van Netten, Chris
2009-01-15
A small air sampling system using standard air filter sampling technology has been used to monitor the air in aircraft. The device is a small ABS constructed cylinder 5 cm in diameter and 9 cm tall and can be operated by non technical individuals at an instant notice. It is completely self contained with a 4 AAA cell power supply, DC motor, a centrifugal fan, and accommodates standard 37 mm filters and backup pads. The monitor is totally enclosed and pre assembled in the laboratory. A 45 degrees twist of the cap switches on the motor and simultaneously opens up the intake ports and exhaust ports allowing air to pass through the filter. A reverse 45 degrees twist of the cap switches off the motor and closes all intake and exhaust ports, completely enclosing the filter. The whole monitor is returned to the laboratory by standard mail for analysis and reassembly for future use. The sampler has been tested for electromagnetic interference and has been approved for use in aircraft during all phases of flight. A set of samples taken by a BAe-146-300 crew member during two flights in the same aircraft and analyzed by GC-MS, indicated exposure to tricresyl phosphate (TCP) levels ranging from 31 to 83 nanograms/m(3) (detection limit <4.5 nanograms/m(3)). The latter elevated level was associated with the use of the auxiliary power unit (APU) in the aircraft. It was concluded that the air sampler was capable of monitoring air concentrations of TCP isomers in aircraft above 4.5 nanogram/m(3).
Design of point-of-care (POC) microfluidic medical diagnostic devices
NASA Astrophysics Data System (ADS)
Leary, James F.
2018-02-01
Design of inexpensive and portable hand-held microfluidic flow/image cytometry devices for initial medical diagnostics at the point of initial patient contact by emergency medical personnel in the field requires careful design in terms of power/weight requirements to allow for realistic portability as a hand-held, point-of-care medical diagnostics device. True portability also requires small micro-pumps for high-throughput capability. Weight/power requirements dictate use of super-bright LEDs and very small silicon photodiodes or nanophotonic sensors that can be powered by batteries. Signal-to-noise characteristics can be greatly improved by appropriately pulsing the LED excitation sources and sampling and subtracting noise in between excitation pulses. The requirements for basic computing, imaging, GPS and basic telecommunications can be simultaneously met by use of smartphone technologies, which become part of the overall device. Software for a user-interface system, limited real-time computing, real-time imaging, and offline data analysis can be accomplished through multi-platform software development systems that are well-suited to a variety of currently available cellphone technologies which already contain all of these capabilities. Microfluidic cytometry requires judicious use of small sample volumes and appropriate statistical sampling by microfluidic cytometry or imaging for adequate statistical significance to permit real-time (typically < 15 minutes) medical decisions for patients at the physician's office or real-time decision making in the field. One or two drops of blood obtained by pin-prick should be able to provide statistically meaningful results for use in making real-time medical decisions without the need for blood fractionation, which is not realistic in the field.
DETAILED ABUNDANCES OF STARS WITH SMALL PLANETS DISCOVERED BY KEPLER. I. THE FIRST SAMPLE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schuler, Simon C.; Vaz, Zachary A.; Santrich, Orlando J. Katime
2015-12-10
We present newly derived stellar parameters and the detailed abundances of 19 elements of seven stars with small planets discovered by NASA's Kepler Mission. Each star, save one, has at least one planet with a radius ≤1.6 R{sub ⊕}, suggesting a primarily rocky composition. The stellar parameters and abundances are derived from high signal-to-noise ratio, high-resolution echelle spectroscopy obtained with the 10 m Keck I telescope and High Resolution Echelle Spectrometer using standard spectroscopic techniques. The metallicities of the seven stars range from −0.32 to +0.13 dex, with an average metallicity that is subsolar, supporting previous suggestions that, unlike Jupiter-typemore » giant planets, small planets do not form preferentially around metal-rich stars. The abundances of elements other than iron are in line with a population of Galactic disk stars, and despite our modest sample size, we find hints that the compositions of stars with small planets are similar to stars without known planets and with Neptune-size planets, but not to those of stars with giant planets. This suggests that the formation of small planets does not require exceptional host-star compositions and that small planets may be ubiquitous in the Galaxy. We compare our derived abundances (which have typical uncertainties of ≲0.04 dex) to the condensation temperature of the elements; a correlation between the two has been suggested as a possible signature of rocky planet formation. None of the stars demonstrate the putative rocky planet signature, despite at least three of the stars having rocky planets estimated to contain enough refractory material to produce the signature, if real. More detailed abundance analyses of stars known to host small planets are needed to verify our results and place ever more stringent constraints on planet formation models.« less
Chemical Conversion of Anhydrous Hydrogen Fluoride for Safe Disposal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blake, Thomas A.; Brauer, Carolyn S.; Bachmann, William J.
A procedure for the safe conversion of a small (~ 1 gram) quantity of anhydrous hydrogen fluoride to calcium fluoride is described. The purpose of the conversion is to put the toxic, corrosive, gaseous compound into a chemical form that is a less toxic solid (calcium fluoride) and easier to dispose of. The hydrogen fluoride, which was contained in a 50 cc metal sample cylinder, was drawn by a small mechanical vacuum pump through an all-metal gas manifold and into a metal trap containing alternating layers of calcium oxide powder and Teflon turnings. The anhydrous hydrogen fluoride reacts with themore » calcium oxide to produce calcium fluoride and water vapor. Because some of the calcium oxide powder was drawn out of the trap and into the vacuum tubing, it was not possible to quantify the amount of anhydrous hydrogen fluoride converted to calcium fluoride. However, it was noted that there was a temperature rise in the trap when the gas was flowing through it, and no HF gas was detected at the vacuum pump exhaust at this time using a colorimetric Dräger tube. The trap was sealed and disposed of as solid chemical waste.« less
Invited Review Small is beautiful: The analysis of nanogram-sized astromaterials
NASA Astrophysics Data System (ADS)
Zolensky, M. E.; Pieters, C.; Clark, B.; Papike, J. J.
2000-01-01
The capability of modern methods to characterize ultra-small samples is well established from analysis of interplanetary dust particles (IDPs), interstellar grains recovered from meteorites, and other materials requiring ultra-sensitive analytical capabilities. Powerful analytical techniques are available that require, under favorable circumstances, single particles of only a few nanograms for entire suites of fairly comprehensive characterizations. A returned sample of >1,000 particles with total mass of just one microgram permits comprehensive quantitative geochemical measurements that are impractical to carry out in situ by flight instruments. The main goal of this paper is to describe the state-of-the-art in microanalysis of astromaterials. Given that we can analyze fantastically small quantities of asteroids and comets, etc., we have to ask ourselves how representative are microscopic samples of bodies that measure a few to many km across? With the Galileo flybys of Gaspra and Ida, it is now recognized that even very small airless bodies have indeed developed a particulate regolith. Acquiring a sample of the bulk regolith, a simple sampling strategy, provides two critical pieces of information about the body. Regolith samples are excellent bulk samples since they normally contain all the key components of the local environment, albeit in particulate form. Furthermore, since this fine fraction dominates remote measurements, regolith samples also provide information about surface alteration processes and are a key link to remote sensing of other bodies. Studies indicate that a statistically significant number of nanogram-sized particles should be able to characterize the regolith of a primitive asteroid, although the presence of larger components within even primitive meteorites (e.g.. Murchison), e.g. chondrules, CAI, large crystal fragments, etc., points out the limitations of using data obtained from nanogram-sized samples to characterize entire primitive asteroids. However, most important asteroidal geological processes have left their mark on the matrix, since this is the finest-grained portion and therefore most sensitive to chemical and physical changes. Thus, the following information can be learned from this fine grain size fraction alone: (1) mineral paragenesis; (2) regolith processes, (3) bulk composition; (4) conditions of thermal and aqueous alteration (if any); (5) relationships to planets, comets, meteorites (via isotopic analyses, including oxygen; (6) abundance of water and hydrated material; (7) abundance of organics; (8) history of volatile mobility, (9) presence and origin of presolar and/or interstellar material. Most of this information can even be obtained from dust samples from bodies for which nanogram-sized samples are not truly representative. Future advances in sensitivity and accuracy of laboratory analytical techniques can be expected to enhance the science value of nano- to microgram sized samples even further. This highlights a key advantage of sample returns - that the most advanced analysis techniques can always be applied in the laboratory, and that well-preserved samples are available for future investigations.
Origin of Tungsten Excess in Komatiites
NASA Astrophysics Data System (ADS)
Becker, H.; Brandon, A. D.; Walker, R. J.
2004-12-01
The limited database available for W abundances in komatiites (n=7, Newsom et al., 1996) suggests that when melting and fractional crystallization effects are filtered out, these komatiites have about 10 times higher W, compared to other mantle-derived mafic-ultramafic magmas (MORB, OIB). The excess of W in the komatiites relative to lithophile highly incompatible elements becomes obvious when compared with the low concentrations of the light REE Ce and Nd (about 1-2 ug/g in many komatiites, compared to > 10 ug/g in most MORB and OIB). In order to increase the komatiite W database, komatiite samples from Phanerozoic (Gorgona Island) and Archean terraines (Boston Creek/Canada, Belingwe/South Africa, 2.7 Ga) were dissolved and W was separated in order to obtain W concentrations by isotope dilution. Except for one sample from Gorgona Island with low W (23 ng/g), samples from all three locales show high W (516 to 2643 ng/g), with most samples containing near 700 ng/g W. Three Hawaiian picrites (H23, LO-02-04, MK-1-6) were also analyzed for comparative purposes and contain 75, 163 and 418 ng/g W, respectively. The W concentrations in the Hawaiian picrites are comparable or lower than W concentrations in Hawaiian tholeiites (Newsom et al., 1996). Mass balance considerations suggest that it is unlikely that the W excess in komatiites reflects W contributions to the mantle sources of komatiites from the outer core. The W enrichment could result from shallow-level alteration processes if primary W abundances of komatiites were low and W was added via fluids, containing W and other fluid-mobile elements derived from crustal rocks. Because most W in such samples would be of crustal origin, small contributions from the outer core may be difficult to detect using 182W systematics (Schersten et al., 2003).
Importance of benthic prey for fishes in coral reef-associated sediments
DeFelice, R.C.; Parrish, J.D.
2003-01-01
The importance of open, sandy substrate adjacent to coral reefs as habitat and a food source for fishes has been little studied in most shallow tropical waters in the Pacific, including Hawai'i. In this study, in Hanalei Bay, Hiwai'i, we identified and quantified the major invertebrate fauna (larger than 0.5 mm) in the well-characterized sands adjoining the shallow fringing reefs. Concurrently, we identified the fish species that seemed to make substantial use of these sand habitats, estimated their density there, sampled their gut contents to examine trophic links with the sand habitat, and made other observations and collections to determine the times, locations, and types of activity there. A variety of (mostly small) polychaeres were dominant in the sediments at most sampling stations, along with many small crustaceans (e.g., amphipods, isopods, ostracods, and small shrimps) and fair numbers of mollusks (especially bivalves) and small echinoids. Fish guts examined contained ???77% of the total number of benthic taxa collected, including nearly all those just listed. However, fish consumption was selective, and the larger shrimps, crabs, and small cryptic fishes were dominant in the diets of most of the numerous predator taxa. Diets of benthic-feeding fishes showed relatively low specific overlap. The fish fauna in this area included substrate-indifferent pelagics, species with various degrees of reef relatedness, reef-restricted species, and (at the other extreme) permanent cryptic sand dwellers. Data on occurrence and movements of fishes indicated that a band of sandy substrate several tens of meters wide next to the reef was an active area for fishes, and activity was considerably different at different times of day and for fish of different ages. These results imply an important trophic role for the benthos in these near-reef habitats in support of reef-associated fishes.
A potpourrie of regolith breccias: ``New'' samples from the Apollo 14, 16, and 17 landing sites
NASA Astrophysics Data System (ADS)
Jerde, Eric A.; Warren, Paul H.; Morris, Richard V.; Heiken, Grant H.; Vaniman, David T.
1987-09-01
Forty suspected regolith breccias from the Apollo 14, 16, and 17 landing sites were studied as part of a search for regolith samples exotic to the small traverse areas associated with these missions, as well as a general effort to constrain the nature and origins of regolith breccias. Of these 40 samples, 31 are indeed regolith breccias. Regolith breccias from Apollo 14 exhibit much greater compositional diversity than their soil (sensu stricto) counterparts: 14004,55 displays incompatible element concentrations about 1.4× those found in typical Apollo 14 regolith, while 14315 is radically different in many respects (higher Al, lower Mg and Fe, lower incompatible elements) from all other Apollo 14 regolith materials, and hence probably exotic to the Apollo 14 traverse area. Application of ``mixing'' models to Apollo 14 regolith materials suggests that whereas ``normal'' Apollo 14 regolith contains only slightly more ferroan anorthosite (FA) than alkali anorthosite (AA) and far more KREEP than FA and AA combined, 14315 contains more FA than KREEP and roughly 10 times more FA than AA. Three ``new'' regolith breccias from Apollo 16 bring to 20 the total number of regolith breccias that have been analyzed for Mg and Fe from the site. The molar Mg/)Mg+Fe) (or mg*) ratios of lunar regolith breccias are of great interest, because lunar meteorite ALH81005 has a much higher mg* than two other lunar meteoritic regolith breccias (Y791197 and Y82192/3), even though these three samples are remarkably similar in all other compositional respects. A bimodality in mg* among Apollo 16 regolith breccias may result from: (1) statistical scattering among the small number of samples, (2) a tendency for older regolith breccias from this site to be compositionally distinct form their younger counterparts, or (3) differences between the Cayley and Descartes Formations. Among 10 samples from Apollo 17, all but one proved to be typical Apollo 17 regolith breccias. However, 72504,10 is >99% pure pyroclastic glass, compositionally identical to the Apollo 1 orange galss (74220), even though 72504,10 was obtained at a location over 4 km from Shorty Crater where 74220 was obtained. The nearly pure concentration of 74220-identical glass spherules in 72504-10 attests to the widespread distribution of these distinctive deposits.
Campbell, T.R.
1996-01-01
A number of potentially hazardous chemicals were used at an asphalt plant on the Fort Bragg U.S. Army Reservation near Fayetteville, North Carolina. This plant was demolished in the late 1960's. Samples collected from soil, ground water, surface water, and streambed sediment were tested for the presence of contaminants. The sediment immediately underlying the demolished asphalt plant site consists mainly of sands, silts, and clayey sands with interbedded clay occurring at various depths. About 12 inches of rainfall per year infiltrate the unconfined surficial aquifer. The water table in this area is about 233 to 243 feet above sea level. Local ground water moves laterally, mainly towards the north- to-northwest at a rate of about 35 feet per year. where it discharges to Tank Creek, Little River, or one of their tributaries. A series of confining clays separate the surficial aquifer from the underlying upper Cape Fear aquifer. These clays help retard vertical migration of constituents dissolved in ground water. The saprolite-bedrock aquifer lies below the upper Cape Fear aquifer. In general ground water in the seven monitoring wells screened in the upper and lower part of the surficial aquifer did not contain detectable concentrations of chemicals related to past asphalt-plant activities. A small number of chemicals that were assumed to be unrelated to the asphalt plant were present in some of the study area monitoring wells. Ground water in four wells contained concentrations of organochlorine pesticides. Of these pesticides, concentrations of gamma-benzene hexachloride (lindane) (maximum of 0.76 micrograms per liter) exceeded the U.S. Environmental Protection Agency maximum contaminant level of 0.2 micrograms per liter in two wells. In addition, one well contained a trichloroethane concentration (7.7 micrograms per liter) that is assumed to be unrelated to demolished asphalt-plant operations, but exceeded the U.S. Environmental Protection Agency maximum contaminant level of 5.0 micrograms per liter. One well contained a fluoride concentration of 5.2 milligrams per liter that exceeded the U.S. Environmental Protection Agency maximum contaminant level of 4.0 milligrams per liter. Total and dissolved metals concentrations were generally typical of background levels. Some of the wells contained elevated levels of chloride (maximum of 749 milligrams per liter), specific conductance (maximum of 2,780 microsiemens per centimeter at 25 degrees Celsius), and dissolved solids (maximum of 1,520 milligrams per liter). Twelve of twenty-two soil samples that were collected at various depths at monitoring-well locations did not contain volatile organic compounds or polynuclear aromatic hydrocarbons. The remaining ten soil samples contained very low concentrations of polynuclear aromatic hydrocarbons and (or) analytical laboratory-related volatile organic compounds. The maximum concentrations were for fluoranthene and pyrene, at 780 and 750 micrograms per kilogram, respectively. In general, the polynuclear aromatic hydrocarbon concentrations were in sediment near the land surface. Streambed sediment from an unnamed, eastern tributary to Tank Creek in the eastern part of the site contained a small number of organochlorine pesticide compounds (a maximum of 1,400 milligrams per kilogram of 4,4'-DDD) and total petroleum hydrocarbons (113 milligrams per kilogram). Concentrations of metals and other inorganic constituents were generally typical of background concentrations. Surface water in this tributary did not contain elevated concentrations of anthropogenic chemicals.
Garcia, Anthony R.; Johnston, Roger G.; Martinez, Ronald K.
2000-01-01
A fluid-sampling tool for obtaining a fluid sample from a container. When used in combination with a rotatable drill, the tool bores a hole into a container wall, withdraws a fluid sample from the container, and seals the borehole. The tool collects fluid sample without exposing the operator or the environment to the fluid or to wall shavings from the container.
Chemical characterization of territorial marking fluid of male Bengal tiger, Panthera tigris.
Burger, B V; Viviers, M Z; Bekker, J P I; le Roux, M; Fish, N; Fourie, W B; Weibchen, G
2008-05-01
The territorial marking fluid of the male Bengal tiger, Panthera tigris, consists of a mixture of urine and a small quantity of lipid material that may act as a controlled-release carrier for the volatile constituents of the fluid. Using gas chromatography and gas chromatography-mass spectrometry, 98 volatile compounds and elemental sulfur were identified in the marking fluid. Another 16 volatiles were tentatively identified. The majority of these compounds were alkanols, alkanals, 2-alkanones, branched and unbranched alkanoic acids, dimethyl esters of dicarboxylic acids, gamma- and delta-lactones, and compounds containing nitrogen or sulfur. Several samples of the marking fluid contained pure (R)-3-methyl-2-octanone, (R)-3-methyl-2-nonanone, and (R)-3-methyl-2-decanone, but these ketones were partly or completely racemized in other samples. The gamma-lactone (S)-(+)-(Z)-6-dodecen-4-olide and the C(8) to C(16) saturated (R)-gamma-lactones and (S)-delta-lactones were present in high enantiomeric purities. The chiral carboxylic acids, 2-methylnonanoic acid, 2-methyldecanoic acid, 2-methylundecanoic acid, and 2-ethylhexanoic acid were racemates. Cadaverine, putrescine, and 2-acetylpyrroline, previously reported as constituents of tiger urine, were not detected. The dominant contribution of some ketones, fatty acids, and lactones to the composition of the headspace of the marking fluid suggests that these compounds may be important constituents of the pheromone. Although it constitutes only a small proportion, the lipid fraction of the fluid contained larger quantities of the volatile organic compounds than the aqueous fraction (urine). The lipid derives its role as controlled-release carrier of the chemical message left by the tiger, from its affinity for the volatiles of the marking fluid. Six proteins with masses ranging from 16 to 69 kDa, inter alia, the carboxylesterase-like urinary protein known as cauxin, previously identified in the urine of the domestic cat and other felid species, were identified in the urine fraction of the marking fluid.
NASA Astrophysics Data System (ADS)
Yi, Zhou; Deng, Pei-Na; Zhang, Li-Li; Li, Hua
2016-10-01
The dynamic behaviors of water contained in calcium-silicate-hydrate (C-S-H) gel with different water content values from 10% to 30% (by weight), are studied by using an empirical diffusion model (EDM) to analyze the experimental data of quasi-elastic neutron scattering (QENS) spectra at measured temperatures ranging from 230 K to 280 K. In the study, the experimental QENS spectra with the whole Q-range are considered. Several important parameters including the bound/immobile water elastic coefficient A, the bound water index BWI, the Lorentzian with a half-width at half-maximum (HWHM) Γ 1(Q) and Γ 2(Q), the self-diffusion coefficients D t1 and D t2 of water molecules, the average residence times τ 01 and τ 02, and the proton mean squared displacement (MSD) are obtained. The results show that the QENS spectra can be fitted very well not only for small Q (≤ 1 Å-1) but also for large Q. The bound/immobile water fraction in a C-S-H gel sample can be shown by the fitted BWI. The distinction between bound/immobile and mobile water, which includes confined water and ultra-confined water, can be seen by the fitted MSD. All the MSD tend to be the smallest value below 0.25 Å2 (the MSD of bound/immobile water) as the Q increases to 1.9 Å-1, no matter what the temperature and water content are. Furthermore, by the abrupt changes of the fitted values of D t1, τ 01, and Γ 1(Q), a crossover temperature at 250 K, namely the liquid-to-crystal-like transition temperature, can be identified for confined water in large gel pores (LGPs) and/or small gel pores (SGPs) contained in the C-S-H gel sample with 30% water content.
Protein Buffering in Model Systems and in Whole Human Saliva
Lamanda, Andreas; Cheaib, Zeinab; Turgut, Melek Dilek; Lussi, Adrian
2007-01-01
The aim of this study was to quantify the buffer attributes (value, power, range and optimum) of two model systems for whole human resting saliva, the purified proteins from whole human resting saliva and single proteins. Two model systems, the first containing amyloglucosidase and lysozyme, and the second containing amyloglucosidase and α-amylase, were shown to provide, in combination with hydrogencarbonate and di-hydrogenphosphate, almost identical buffer attributes as whole human resting saliva. It was further demonstrated that changes in the protein concentration as small as 0.1% may change the buffer value of a buffer solution up to 15 times. Additionally, it was shown that there was a protein concentration change in the same range (0.16%) between saliva samples collected at the time periods of 13:00 and others collected at 9:00 am and 17:00. The mode of the protein expression changed between these samples corresponded to the change in basic buffer power and the change of the buffer value at pH 6.7. Finally, SDS Page and Ruthenium II tris (bathophenantroline disulfonate) staining unveiled a constant protein expression in all samples except for one 50 kDa protein band. As the change in the expression pattern of that 50 kDa protein band corresponded to the change in basic buffer power and the buffer value at pH 6.7, it was reasonable to conclude that this 50 kDa protein band may contain the protein(s) belonging to the protein buffer system of human saliva. PMID:17327922
Fluid sampling system for a nuclear reactor
Lau, Louis K.; Alper, Naum I.
1994-01-01
A system of extracting fluid samples, either liquid or gas, from the interior of a nuclear reactor containment utilizes a jet pump. To extract the sample fluid, a nonradioactive motive fluid is forced through the inlet and discharge ports of a jet pump located outside the containment, creating a suction that draws the sample fluid from the containment through a sample conduit connected to the pump suction port. The mixture of motive fluid and sample fluid is discharged through a return conduit to the interior of the containment. The jet pump and means for removing a portion of the sample fluid from the sample conduit can be located in a shielded sample grab station located next to the containment. A non-nuclear grade active pump can be located outside the grab sampling station and the containment to pump the nonradioactive motive fluid through the jet pump.
Fluid sampling system for a nuclear reactor
Lau, L.K.; Alper, N.I.
1994-11-22
A system of extracting fluid samples, either liquid or gas, from the interior of a nuclear reactor containment utilizes a jet pump. To extract the sample fluid, a nonradioactive motive fluid is forced through the inlet and discharge ports of a jet pump located outside the containment, creating a suction that draws the sample fluid from the containment through a sample conduit connected to the pump suction port. The mixture of motive fluid and sample fluid is discharged through a return conduit to the interior of the containment. The jet pump and means for removing a portion of the sample fluid from the sample conduit can be located in a shielded sample grab station located next to the containment. A non-nuclear grade active pump can be located outside the grab sampling station and the containment to pump the nonradioactive motive fluid through the jet pump. 1 fig.
NASA Technical Reports Server (NTRS)
Kumar, A.; Graves, R. A., Jr.
1980-01-01
A user's guide is provided for a computer code which calculates the laminar and turbulent hypersonic flows about blunt axisymmetric bodies, such as spherically blunted cones, hyperboloids, etc., at zero and small angles of attack. The code is written in STAR FORTRAN language for the CDC-STAR-100 computer. Time-dependent, viscous-shock-layer-type equations are used to describe the flow field. These equations are solved by an explicit, two-step, time asymptotic, finite-difference method. For the turbulent flow, a two-layer, eddy-viscosity model is used. The code provides complete flow-field properties including shock location, surface pressure distribution, surface heating rates, and skin-friction coefficients. This report contains descriptions of the input and output, the listing of the program, and a sample flow-field solution.
Kirstein, L M; Mellors, J W; Rinaldo, C R; Margolick, J B; Giorgi, J V; Phair, J P; Dietz, E; Gupta, P; Sherlock, C H; Hogg, R; Montaner, J S; Muñoz, A
1999-08-01
We conducted two studies to determine the potential influence of delays in blood processing, type of anticoagulant, and assay method on human immunodeficiency virus type 1 (HIV-1) RNA levels in plasma. The first was an experimental study in which heparin- and EDTA-anticoagulated blood samples were collected from 101 HIV-positive individuals and processed to plasma after delays of 2, 6, and 18 h. HIV-1 RNA levels in each sample were then measured by both branched-DNA (bDNA) and reverse transcriptase PCR (RT-PCR) assays. Compared to samples processed within 2 h, the loss (decay) of HIV-1 RNA in heparinized blood was significant (P < 0.05) but small after 6 h (bDNA assay, -0.12 log(10) copies/ml; RT-PCR, -0.05 log(10) copies/ml) and after 18 h (bDNA assay, -0.27 log(10) copies/ml; RT-PCR, -0.15 log(10) copies/ml). Decay in EDTA-anticoagulated blood was not significant after 6 h (bDNA assay, -0.002 log(10) copies/ml; RT-PCR, -0.02 log(10) copies/ml), but it was after 18 h (bDNA assay, -0.09 log(10) copies/ml; RT-PCR, -0.09 log(10) copies/ml). Only 4% of samples processed after 6 h lost more than 50% (>/=0.3 log(10) copies/ml) of the HIV-1 RNA, regardless of the anticoagulant or the assay that was used. The second study compared HIV-1 RNA levels in samples from the Multicenter AIDS Cohort Study (MACS; samples were collected in heparin-containing tubes in 1985, had a 6-h average processing delay, and were assayed by bDNA assay) and the British Columbia Drug Treatment Program (BCDTP) (collected in EDTA- or acid citrate dextrose-containing tubes in 1996 and 1997, had a 2-h maximum processing delay, and were assayed by RT-PCR). HIV-1 RNA levels in samples from the two cohorts were not significantly different after adjusting for CD4(+)-cell count and converting bDNA assay values to those corresponding to the RT-PCR results. In summary, the decay of HIV-1 RNA measured in heparinized blood after 6 h was small (-0.05 to -0.12 log(10) copies/ml), and the minor impact of this decay on HIV-1 RNA concentrations in archived plasma samples of the MACS was confirmed by the similarity of CD4(+)-cell counts and assay-adjusted HIV-1 RNA concentrations in the MACS and BCDTP.
Possible importance of algal toxins in the Salton Sea, California
Reifel, K.M.; McCoy, M.P.; Rocke, T.E.; Tiffany, M.A.; Hurlbert, S.H.; Faulkner, D.J.
2002-01-01
In response to wildlife mortality including unexplained eared grebe (Podiceps nigricollis) die-off events in 1992 and 1994 and other mortality events including large fish kills, a survey was conducted for the presence of algal toxins in the Salton Sea. Goals of this survey were to determine if and when algal toxins are present in the Salton Sea and to describe the phytoplankton composition during those times. A total of 29 samples was collected for toxicity analysis from both nearshore and midlake sites visited biweekly from January to December 1999. Dinoflagellates and diatoms dominated most samples, but some were dominated by a prymnesiophyte (Pleurochrysis pseudoroscoffensis) or a raphidophyte (Chattonella marina). Several types of blooms were observed and sampled. The dinoflagellate Gyrodinium uncatenum formed an extensive, dense (up to 310 000 cells ml−1) and long-lasting bloom during the winter in 1999. A coccolithophorid, Pleurochrysis pseudoroscoffensis, occurred at high densities in surface films and nearshore areas during the spring and summer of 1999. These surface films also contained high densities of one or two other species (an unidentified scrippsielloid, Heterocapsa niei, Chattonella marina). Localized blooms were also observed in the Salton Sea. An unknown small dinoflagellate reached high densities (110 000 cells ml−1) inside Varner Harbor, and an unidentified species of Gymnodinium formed a dense (270 000 cells ml−1) band along part of the southern shoreline during the summer. Three species known to produce toxins in other systems were found. Protoceratium reticulatum (=Gonyaulax grindleyi) and Chattonella marina were found in several samples taken during summer months, and Prorocentrum minimum was found in low densities in several samples. Extracts of most samples, including those containing known toxic species, showed a low level (<10% mortality across all concentrations) of activity in the brine shrimp lethality assay and were not considered toxic. All sample extracts tested in the mouse bioassay showed no activity. One sample extract taken from the bloom of the small dinoflagellate was highly active (100% mortality across all concentrations) in the brine shrimp lethality assay, but the active material could not be isolated. While dense algal blooms are common at the Salton Sea, no evidence gathered in this study suggests that algal toxins are present within phytoplankton cells; however, toxins actively excreted by cells may have been missed. Blooms of phytoplankton likely contribute to wildlife mortality at the Salton Sea. Possible mechanisms including intoxication due to ingestion of feathers in grebes and waterlogging caused by changes in surface tension are discussed.
A new static sampler for airborne total dust in workplaces.
Mark, D; Vincent, J H; Gibson, H; Lynch, G
1985-03-01
This paper describes the development and laboratory testing of a new static dust sampler for airborne total dust in workplaces. Particular attention is paid to designing the sampling head and entry consistent with the concept of inspirability which in turn defines a biologically-relevant aspiration efficiency. The sampling head has a small cylindrical body and a transverse entry slot with thin protruding lips forming an integral part of a weighable capsule containing a 37 mm filter which collects all of the sampled dust (without introducing errors due to external particle blow-off or internal wall losses). A battery-powered sampling pump provides both air suction at 3 L/min and rigid mounting for the sampling head. The sampling head is rotated continuously through 360 degrees at approximately 1.5 rpm by a simple electric drive, connected to the stationary pump through a rotating seal. Wind tunnel testing of the instrument showed it to display an entry efficiency very close to the inspirability curve of Vincent and Armbruster (now recommended by the ACGIH Technical Committee on Air Sampling Procedures for defining inspirable particulate matter (IPM] for particles of aerodynamic diameter up to 90 micron and for windspeeds in the range of one to three m/sec.
Analytical Results from Routine DSSHT and SEHT Monthly Samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.
2016-08-17
Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 8B have been analyzed for 238Pu, 90Sr, 137Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and anions (Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatch samples. The Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU) continue to show more than adequate Pu and Sr removal for times when monosodium titanate (MST) is used. Even with nomore » MST strike being performed there exists some small Pu and Sr removal, likely from filtration of fines containing these elements. The Cs removal continues to be excellent, with decontamination factors (DF) averaging 16,400. The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior. SRNL recommends that a sample of the strip feed be analyzed for cation and anion content if a further decline in boron concentration is noted in future SEHT samples.« less
Zhang, Gang; Liang, Zhaohui; Yin, Jian; Fu, Wenbin; Li, Guo-Zheng
2013-01-01
Chronic neck pain is a common morbid disorder in modern society. Acupuncture has been administered for treating chronic pain as an alternative therapy for a long time, with its effectiveness supported by the latest clinical evidence. However, the potential effective difference in different syndrome types is questioned due to the limits of sample size and statistical methods. We applied machine learning methods in an attempt to solve this problem. Through a multi-objective sorting of subjective measurements, outstanding samples are selected to form the base of our kernel-oriented model. With calculation of similarities between the concerned sample and base samples, we are able to make full use of information contained in the known samples, which is especially effective in the case of a small sample set. To tackle the parameters selection problem in similarity learning, we propose an ensemble version of slightly different parameter setting to obtain stronger learning. The experimental result on a real data set shows that compared to some previous well-known methods, the proposed algorithm is capable of discovering the underlying difference among different syndrome types and is feasible for predicting the effective tendency in clinical trials of large samples.
Nyberg, G; Mårtensson, E
1986-01-01
The effects were tested of eight common types of blood collection tubes and two types of "plasma separators" on the stability of the tricyclic antidepressants amitriptyline, imipramine, clomipramine, and their monodemethylated metabolites in venous blood samples. Although EDTA-containing Venoject lavender and Vacutainer lavender tubes seemed to give the most stable plasma samples, and Venoject red the most stable serum samples, the differences were too small to have practical consequences. Vacutainer royal blue collection tubes gave significant losses of greater than 20% of some of the substances. The tubes with serum separator gel or filter proved unsuitable, since they were responsible for losses of greater than 40%. The losses were not caused by redistribution between blood cells and plasma but occurred mainly as a result of contact between the contents and the caps of the tubes. Experiments with freezing, thawing, and storage of samples showed that freshly sampled blood could be stored at room temperature for 24 h in Venoject green tubes without significant losses. Serum samples could be stored at refrigerator temperature for 4 weeks without important losses. Freezing, thawing, and storage at -20 degrees C did not influence the serum or plasma concentrations.
Knaack, Jennifer S; Zhou, Yingtao; Abney, Carter W; Prezioso, Samantha M; Magnuson, Matthew; Evans, Ronald; Jakubowski, Edward M; Hardy, Katelyn; Johnson, Rudolph C
2012-11-20
We have developed a novel immunomagnetic scavenging technique for extracting cholinesterase inhibitors from aqueous matrixes using biological targeting and antibody-based extraction. The technique was characterized using the organophosphorus nerve agent VX. The limit of detection for VX in high-performance liquid chromatography (HPLC)-grade water, defined as the lowest calibrator concentration, was 25 pg/mL in a small, 500 μL sample. The method was characterized over the course of 22 sample sets containing calibrators, blanks, and quality control samples. Method precision, expressed as the mean relative standard deviation, was less than 9.2% for all calibrators. Quality control sample accuracy was 102% and 100% of the mean for VX spiked into HPLC-grade water at concentrations of 2.0 and 0.25 ng/mL, respectively. This method successfully was applied to aqueous extracts from soil, hamburger, and finished tap water spiked with VX. Recovery was 65%, 81%, and 100% from these matrixes, respectively. Biologically based extractions of organophosphorus compounds represent a new technique for sample extraction that provides an increase in extraction specificity and sensitivity.
Broadband thermal optical limiter for the protection of eyes and sensors
NASA Astrophysics Data System (ADS)
Justus, Brian L.; Huston, Alan L.; Campillo, Anthony J.
1994-05-01
A broadband thermal optical limiter for protecting a light sensitive object from intense laser beams at all near ultraviolet, visible and near infrared wavelengths is disclosed. The broadband thermal optical limiter comprises: a sample cell containing a solution of broadband absorber material dissolved in a thermal solvent; and a first optical device for converging an incident laser beam into the sample cell. The sample cell is responsive to a converged incident laser beam below a predetermined intensity level for passing therethrough the converged incident laser beam below the predetermined intensity level. The sample cell is also responsive to a converged incident laser beam at or above a predetermined intensity level for thermally defocusing substantially all of the converged incident laser beam in different directions and passing therethrough only a remaining small portion of the converged incident laser beam at or above the predetermined intensity level. The broadband thermal optical limiter further includes a second optical device for focusing substantially all of the laser beam passing through the sample cell into the light sensitive object to be protected.
Identification and imaging of modern paints using Secondary Ion Mass Spectrometry with MeV ions
NASA Astrophysics Data System (ADS)
Bogdanović Radović, Iva; Siketić, Zdravko; Jembrih-Simbürger, Dubravka; Marković, Nikola; Anghelone, Marta; Stoytschew, Valentin; Jakšić, Milko
2017-09-01
Secondary Ion Mass Spectrometry using MeV ion excitation was applied to analyse modern paint materials containing synthetic organic pigments and binders. It was demonstrated that synthetic organic pigments and binder components with molecular masses in the m/z range from 1 to 1200 could be identified in different paint samples with a high efficiency and in a single measurement. Different ways of mounting of mostly insulating paint samples were tested prior to the analysis in order to achieve the highest possible yield of pigment main molecular ions. As Time-of-Flight mass spectrometer for MeV Secondary Ion Mass Spectrometry is attached to the heavy ion microprobe, molecular imaging on cross-sections of small paint fragments was performed using focused ions. Due to the fact that molecules are extracted from the uppermost layer of the sample and to avoid surface contamination, the paint samples were not embedded in the resin as is usually done when imaging of paint samples using different techniques in the field of cultural heritage.
Jankowski, Stéphane; Currie-Fraser, Erica; Xu, Licen; Coffa, Jordy
2008-01-01
Annotated DNA samples that had been previously analyzed were tested using multiplex ligation-dependent probe amplification (MLPA) assays containing probes targeting BRCA1, BRCA2, and MMR (MLH1/MSH2 genes) and the 9p21 chromosomal region. MLPA polymerase chain reaction products were separated on a capillary electrophoresis platform, and the data were analyzed using GeneMapper v4.0 software (Applied Biosystems, Foster City, CA). After signal normalization, loci regions that had undergone deletions or duplications were identified using the GeneMapper Report Manager and verified using the DyeScale functionality. The results highlight an easy-to-use, optimal sample preparation and analysis workflow that can be used for both small- and large-scale studies. PMID:19137113
The UK Biobank sample handling and storage validation studies.
Peakman, Tim C; Elliott, Paul
2008-04-01
and aims UK Biobank is a large prospective study in the United Kingdom to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. It involves the collection of blood and urine from 500 000 individuals aged between 40 and 69 years. How the samples are collected, processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. A series of validation studies was recommended to test the robustness of the draft sample handling and storage protocol. Samples of blood and urine were collected from 40 healthy volunteers and either processed immediately according to the protocol or maintained at specified temperatures (4 degrees C for all tubes with the exception of vacutainers containing acid citrate dextrose that were maintained at 18 degrees C) for 12, 24 or 36 h prior to processing. A further sample was maintained for 24 h at 4 degrees C, processed and the aliquots frozen at -80 degrees C for 20 days and then thawed under controlled conditions. The stability of the samples was compared for the different times in a wide variety of assays. The samples maintained at 4 degrees C were stable for at least 24 h after collection for a wide range of assays. Small but significant changes were observed in metabonomic studies in samples maintained at 4 degrees C for 36 h. There was no degradation of the samples for a range of biochemical assays after short-term freezing and thawing under controlled conditions. Whole blood maintained at 18 degrees C for 24 h in vacutainers containing acid citrate dextrose is suitable for viral immortalization techniques. The validation studies reported in this supplement provide justification for the sample handling and storage procedures adopted in the UK Biobank project.
Urashima, Tadasu; Kobayashi, Mami; Asakuma, Sadaki; Uemura, Yusuke; Arai, Ikichi; Fukuda, Kenji; Saito, Tadao; Mogoe, Toshihiro; Ishikawa, Hajime; Fukui, Yutaka
2007-02-01
Samples of milk from a Bryde's whale and a Sei whale contained 2.7 g/100 mL and 1.7 g/100 mL of hexose, respectively. Both contained lactose as the dominant saccharide along with small amounts of Neu5Ac(alpha2-3)Gal(beta1-4)Glc (3'-N-acetylneuraminyllactose), Neu5Ac(alpha2-6)Gal(beta1-4)Glc (6'-N-acetylneuraminyllactose) and Neu5Ac(alpha2-6)Gal(beta1-4)GlcNAc(beta1-3)Gal(beta1-4)Glc (LST c). The dominance of lactose in the carbohydrate of these milks is similar to that of Minke whale milk and bottlenose dolphin colostrum, but the oligosaccharide patterns are different from those of these two species, illustrating the heterogeneity of milk oligosaccharides among the Cetacea.
Oxidation Kinetics of Chemically Vapor-Deposited Silicon Carbide in Wet Oxygen
NASA Technical Reports Server (NTRS)
Opila, Elizabeth J.
1994-01-01
The oxidation kinetics of chemically vapor-deposited SiC in dry oxygen and wet oxygen (P(sub H2O) = 0.1 atm) at temperatures between 1200 C and 1400 C were monitored using thermogravimetric analysis. It was found that in a clean environment, 10% water vapor enhanced the oxidation kinetics of SiC only very slightly compared to rates found in dry oxygen. Oxidation kinetics were examined in terms of the Deal and Grove model for oxidation of silicon. It was found that in an environment containing even small amounts of impurities, such as high-purity Al2O3 reaction tubes containing 200 ppm Na, water vapor enhanced the transport of these impurities to the oxidation sample. Oxidation rates increased under these conditions presumably because of the formation of less protective sodium alumino-silicate scales.
NASA Astrophysics Data System (ADS)
Lin, Che-Tseng; Huang, Tzu-Yang; Huang, Jau-Jiun; Wu, Nae-Lih; Leung, Man-kit
2016-10-01
Multifunctional co-poly(amic acid) (PAmA) containing pyrene and carboxylic acid side-chains is developed as a binder for the recycled kerf-loss Si-Ni-SiC composite anode. The capacity retention performance of the lithium-ion battery can be apparently enhanced. In a long-cycle test of 300 lithiation/delithiation cycles, 79% of capacity retention is achieved. In considering that the recycled kerf-loss Si sample contains 38 wt% inactive micro-sized SiC abrasive particles, the achieved capacity of 648 mAh g-1 is reasonably high in comparison to other reported values. Small anode thickness expansion of 43% is found in a 100 cycle test, reflecting that the use of the PAmA binder can create strong interconnection among the silicon particles, conductive carbons and copper electrode.
A new sensitive method for detecting human endogenous (leukocyte) pyrogen.
Bodel, P; Miller, H
1978-03-01
Endogenous, or leukocyte pyrogen (EP), the mediator of fever, is currently detected by injection of pyrogen-containing supernatants into rabbits. This assay has been of little value in the study of human fever because it required injection of relatively large amounts of pyrogen. We now report that injection of medium containing human EP produces fever in mice. Supernatant from 1 c 10(5) granulocytes, stimulated by phagocytosis of staphylococci and incubated overnight, or 1 x 10(4) monocytes similarly treated, produce clear pyrogenic responses. This method for detecting EP is about 100-fold more sensitive than the rabbit assay, and it appears to be specific for EP. Preliminary studies of EP released by small samples of needle liver biopsies from febrile and afebrile patients suggests that this sensitive assay may be useful for investigations into the mechanisms of clinical fever.
A Sample Return Container with Hermetic Seal
NASA Technical Reports Server (NTRS)
Kong, Kin Yuen; Rafeek, Shaheed; Sadick, Shazad; Porter, Christopher C.
2000-01-01
A sample return container is being developed by Honeybee Robotics to receive samples from a derivative of the Champollion/ST4 Sample Acquisition and Transfer Mechanism or other samplers and then hermetically seal samples for a sample return mission. The container is enclosed in a phase change material (PCM) chamber to prevent phase change during return and re-entry to earth. This container is designed to operate passively with no motors and actuators. Using the sampler's featured drill tip for interfacing, transfer-ring and sealing samples, the container consumes no electrical power and therefore minimizes sample temperature change. The circular container houses a few isolated canisters, which will be sealed individually for samples acquired from different sites or depths. The drill based sampler indexes each canister to the sample transfer position, below the index interface for sample transfer. After sample transfer is completed, the sampler indexes a seal carrier, which lines up seals with the openings of the canisters. The sampler moves to the sealing interface and seals the sample canisters one by one. The sealing interface can be designed to work with C-seals, knife edge seals and cup seals. Again, the sampler provides all sealing actuation. This sample return container and co-engineered sample acquisition system are being developed by Honeybee Robotics in collaboration with the JPL Exploration Technology program.
New Ultra-Compact Dwarf Galaxies in Clusters
NASA Astrophysics Data System (ADS)
Kohler, Susanna
2017-02-01
How do ultra-compact dwarf galaxies (UCDs) galaxies that are especially small and dense form and evolve? Scientists have recently examined distant galaxy clusters, searching for more UCDs to help us answer this question.Origins of DwarfsIn recent years we have discovered a growing sample of small, very dense galaxies. Galaxies that are tens to hundreds of light-years across, with masses between a million and a billion solar masses, fall into category of ultra-compact dwarfs (UCDs).An example of an unresolved compact object from the authors survey that is likely an ultra-compact dwarf galaxy. [Adapted from Zhang Bell 2017]How do these dense and compact galaxies form? Two possibilities are commonly suggested:An initially larger galaxy was tidally stripped during interactions with other galaxies in a cluster, leaving behind only its small, dense core as a UCD.UCDs formed as compact galaxies at very early cosmic times. The ones living in a massive dark matter halo may have been able to remain compact over time, evolving into the objectswe see today.To better understand which of these formation scenarios applies to which galaxies, we need a larger sample size! Our census of UCDs is fairly limited and because theyare small and dim, most of the ones weve discovered are in the nearby universe. To build a good sample, we need to find UCDs at higher redshifts as well.A New SampleIn a recent study, two scientists from University of Michigan have demonstrated how we might find more UCDs. Yuanyuan Zhang (also affiliated with Fermilab) and Eric Bell used the Cluster Lensing and Supernova Survey with Hubble (CLASH) to search 17 galaxy clusters at intermediate redshifts of 0.2 z 0.6, looking for unresolved objects that might be UCDs.The mass and size distributions of the UCD candidates reported in this study, in the context of previously known nuclear star clusters, globular clusters (GCs), UCDs, compact elliptical galaxies (cEs), and dwarf galaxies. [Zhang Bell 2017]Zhang and Bell discovered a sample of compact objects grouped around the central galaxies of the clusters that are consistent with ultra-compact galaxies. The inferred sizes (many around 600 light-years in radius) and masses (roughly one billion solar masses) of these objects suggest that this sample may contain some of the densest UCDs discovered to date.The properties of this new set of UCD candidates arent enough to distinguish between formation scenarios yet, but the authors argue that if we find more such galaxies, we will be able to use the statistics of their spatial and color distributions to determine how they were formed.Zhang and Bell estimate that the 17 CLASH clusters studied in this work each contain an average of 2.7 of these objects in the central million light-years of the cluster. The authors work here suggests that searching wide-field survey data for similar discoveries is a plausible way to increase our sample of UCDs. This will allow us to statistically characterize these dense, compact galaxies and better understand their origins.CitationYuanyuan Zhang and Eric F. Bell 2017 ApJL 835 L2. doi:10.3847/2041-8213/835/1/L2
Inhalation studies on the effects of tremolite and brucite dust in rats
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, J.M.; Addison, J.; Bolton, R.E.
1985-05-01
Samples of commercially used asbestos, especially chrysotile, are frequently contaminated by small amounts of other fibrous minerals. Among these are tremolite and brucite although pure tremolite is also produced commercially in relatively small quantities. In order to determine how harmful commercially exploited tremolite might be in comparison with other asbestos types and to explore the possibility that small amounts of tremolite and brucite as contaminants could significantly affect the pathogenicity of industrially used chrysotile, long-term animal inhalation and injection studies using rats were undertaken with what were considered to be mineralogically pure samples of these minerals. Rats treated with tremolitemore » developed very high levels of pulmonary fibrosis as well as 16 carcinomas and two mesotheliomas in a group of 39 animals. Tremolite thus proved to be the most dangerous mineral that the authors have studied. Animals treated with brucite developed moderate levels of pulmonary fibrosis and two carcinomas. Both tremolite and brucite produced mesotheliomas in greater than 90% of animals following i.p. injection. However, it was found that the supposedly pure brucite in fact contained 10% chrysotile, a level of contamination that could well have been responsible for the pathological changes found in both inhalation and intraperitoneal injection studies. The greatest care should be exercised by industry in handling tremolite or materials contaminated with it.« less
Yan, Y.; Qian, S.; Littrell, K.; ...
2015-02-13
A non-destructive neutron scattering method to precisely measure the uptake of hydrogen and the distribution of hydride precipitates in light water reactor (LWR) fuel cladding was developed. Zircaloy-4 cladding used in commercial LWRs was used to produce hydrided specimens. The hydriding apparatus consists of a closed stainless steel vessel that contains Zr alloy specimens and hydrogen gas. Following hydrogen charging, the hydrogen content of the hydrided specimens was measured using the vacuum hot extraction method, by which the samples with desired hydrogen concentration were selected for the neutron study. Optical microscopy shows that our hydriding procedure results in uniform distributionmore » of circumferential hydrides across the wall. Small angle neutron incoherent scattering was performed in the High Flux Isotope Reactor at Oak Ridge National Laboratory. This study demonstrates that the hydrogen in commercial Zircaloy-4 cladding can be measured very accurately in minutes by this nondestructive method over a wide range of hydrogen concentrations from a very small amount ( 20 ppm) to over 1000 ppm. The hydrogen distribution in a tube sample was obtained by scaling the neutron scattering rate with a factor determined by a calibration process using standard, destructive direct chemical analysis methods on the specimens. This scale factor will be used in future tests with unknown hydrogen concentrations, thus providing a nondestructive method for absolute hydrogen concentration determination.« less
Refractory materials in comet samples
NASA Astrophysics Data System (ADS)
Joswiak, D. J.; Brownlee, D. E.; Nguyen, A. N.; Messenger, S.
2017-08-01
Transmission electron microscope examination of more than 250 fragments, >1 μm from comet Wild 2 and a giant cluster interplanetary dust particle (GCP) of probable cometary origin has revealed four new calcium-aluminum-rich inclusions (CAIs), an amoeboid olivine aggregate (AOA), and an additional AOA or Al-rich chondrule (ARC) object. All of the CAIs have concentric mineral structures and are composed of spinel + anorthite cores surrounded by Al,Ti clinopyroxenes and are similar to two previous CAIs discovered in Wild 2. All of the cometary refractory objects are of moderate refractory character. The mineral assemblages, textures, and bulk compositions of the comet CAIs are similar to nodules in fine-grained, spinel-rich inclusions (FGIs) found in primitive chondrites and like the nodules may be nebular condensates that were altered via solid-gas reactions in the solar nebula. Oxygen isotopes collected on one Wild 2 CAI also match FGIs. The lack of the most refractory inclusions in the comet samples may reflect the higher abundances of small moderately refractory CAI nodules that were produced in the nebula and the small sample sizes collected. In the comet samples, approximately 2-3% of all fragments larger than 1 μm, by number, are CAIs and nearly 50% of all bulbous Stardust tracks contain at least one CAI. We estimate that 0.5 volume % of Wild 2 material and 1 volume % of GCP is in the form of CAIs. ARCs and AOAs account for <1% of the Wild 2 and GCP grains by number.
Solano, Philippe; Ravel, Sophie; Bouyer, Jeremy; Camara, Mamadou; Kagbadouno, Moise S.; Dyer, Naomi; Gardes, Laetitia; Herault, Damien; Donnelly, Martin J.; De Meeûs, Thierry
2009-01-01
Background We undertook a population genetics analysis of the tsetse fly Glossina palpalis gambiensis, a major vector of sleeping sickness in West Africa, using microsatellite and mitochondrial DNA markers. Our aims were to estimate effective population size and the degree of isolation between coastal sites on the mainland of Guinea and Loos Islands. The sampling locations encompassed Dubréka, the area with the highest Human African Trypanosomosis (HAT) prevalence in West Africa, mangrove and savannah sites on the mainland, and two islands, Fotoba and Kassa, within the Loos archipelago. These data are discussed with respect to the feasibility and sustainability of control strategies in those sites currently experiencing, or at risk of, sleeping sickness. Principal Findings We found very low migration rates between sites except between those sampled around the Dubréka area that seems to contain a widely dispersed and panmictic population. In the Kassa island samples, various effective population size estimates all converged on surprisingly small values (10
Pseudolinear gradient ultrahigh-pressure liquid chromatography using an injection valve assembly.
Xiang, Yanqiao; Liu, Yansheng; Stearns, Stanley D; Plistil, Alex; Brisbin, Martin P; Lee, Milton L
2006-02-01
The use of ultrahigh pressures in liquid chromatography (UHPLC) imposes stringent requirements on hardware such as pumps, valves, injectors, connecting tubing, and columns. One of the most difficult components of the UHPLC system to develop has been the sample injector. Static-split injection, which can be performed at pressures up to 6900 bar (100,000 psi), consumes a large sample volume and is very irreproducible. A pressure-balanced injection valve provided better reproducibility, shorter injection time, reduced sample consumption, and greater ease of use; however, it could only withstand pressures up to approximately 1000 bar (15,000 psi). In this study, a new injection valve assembly that can operate at pressures as high as 2070 bar (30,000 psi) was evaluated for UHPLC. This assembly contains six miniature electronically controlled needle valves to provide accurate and precise volumes for introduction into the capillary LC column. It was found that sample volumes as small as several tenths of a nanoliter can be injected, which are comparable to the results obtained from the static-split injector. The reproducibilities of retention time, efficiency, and peak area were investigated, and the results showed that the relative standard deviations of these parameters were small enough for quantitative analyses. Separation experiments using the UHPLC system with this new injection valve assembly showed that this new injector is suitable for both isocratic and gradient operation modes. A newly designed capillary connector was used at a pressure as high as 2070 bar (30,000 psi).
High-density grids for efficient data collection from multiple crystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baxter, Elizabeth L.; Aguila, Laura; Alonso-Mori, Roberto
Higher throughput methods to mount and collect data from multiple small and radiation-sensitive crystals are important to support challenging structural investigations using microfocus synchrotron beamlines. Furthermore, efficient sample-delivery methods are essential to carry out productive femtosecond crystallography experiments at X-ray free-electron laser (XFEL) sources such as the Linac Coherent Light Source (LCLS). To address these needs, a high-density sample grid useful as a scaffold for both crystal growth and diffraction data collection has been developed and utilized for efficient goniometer-based sample delivery at synchrotron and XFEL sources. A single grid contains 75 mounting ports and fits inside an SSRL cassettemore » or uni-puck storage container. The use of grids with an SSRL cassette expands the cassette capacity up to 7200 samples. Grids may also be covered with a polymer film or sleeve for efficient room-temperature data collection from multiple samples. New automated routines have been incorporated into theBlu-Ice/DCSSexperimental control system to support grids, including semi-automated grid alignment, fully automated positioning of grid ports, rastering and automated data collection. Specialized tools have been developed to support crystallization experiments on grids, including a universal adaptor, which allows grids to be filled by commercial liquid-handling robots, as well as incubation chambers, which support vapor-diffusion and lipidic cubic phase crystallization experiments. Experiments in which crystals were loaded into grids or grown on grids using liquid-handling robots and incubation chambers are described. As a result, crystals were screened at LCLS-XPP and SSRL BL12-2 at room temperature and cryogenic temperatures.« less
High-density grids for efficient data collection from multiple crystals
Baxter, Elizabeth L.; Aguila, Laura; Alonso-Mori, Roberto; Barnes, Christopher O.; Bonagura, Christopher A.; Brehmer, Winnie; Brunger, Axel T.; Calero, Guillermo; Caradoc-Davies, Tom T.; Chatterjee, Ruchira; Degrado, William F.; Fraser, James S.; Ibrahim, Mohamed; Kern, Jan; Kobilka, Brian K.; Kruse, Andrew C.; Larsson, Karl M.; Lemke, Heinrik T.; Lyubimov, Artem Y.; Manglik, Aashish; McPhillips, Scott E.; Norgren, Erik; Pang, Siew S.; Soltis, S. M.; Song, Jinhu; Thomaston, Jessica; Tsai, Yingssu; Weis, William I.; Woldeyes, Rahel A.; Yachandra, Vittal; Yano, Junko; Zouni, Athina; Cohen, Aina E.
2016-01-01
Higher throughput methods to mount and collect data from multiple small and radiation-sensitive crystals are important to support challenging structural investigations using microfocus synchrotron beamlines. Furthermore, efficient sample-delivery methods are essential to carry out productive femtosecond crystallography experiments at X-ray free-electron laser (XFEL) sources such as the Linac Coherent Light Source (LCLS). To address these needs, a high-density sample grid useful as a scaffold for both crystal growth and diffraction data collection has been developed and utilized for efficient goniometer-based sample delivery at synchrotron and XFEL sources. A single grid contains 75 mounting ports and fits inside an SSRL cassette or uni-puck storage container. The use of grids with an SSRL cassette expands the cassette capacity up to 7200 samples. Grids may also be covered with a polymer film or sleeve for efficient room-temperature data collection from multiple samples. New automated routines have been incorporated into the Blu-Ice/DCSS experimental control system to support grids, including semi-automated grid alignment, fully automated positioning of grid ports, rastering and automated data collection. Specialized tools have been developed to support crystallization experiments on grids, including a universal adaptor, which allows grids to be filled by commercial liquid-handling robots, as well as incubation chambers, which support vapor-diffusion and lipidic cubic phase crystallization experiments. Experiments in which crystals were loaded into grids or grown on grids using liquid-handling robots and incubation chambers are described. Crystals were screened at LCLS-XPP and SSRL BL12-2 at room temperature and cryogenic temperatures. PMID:26894529
Determination and assessment of total mercury levels in local, frozen and canned fish in Lebanon.
Obeid, Pierre J; El-Khoury, Bilal; Burger, Joanne; Aouad, Samer; Younis, Mira; Aoun, Amal; El-Nakat, John Hanna
2011-01-01
Fish is an important constituent of the Lebanese diet. However, very little attention in our area is given to bring awareness regarding the effect of the toxicity of mercury (Hg) mainly through fish consumption. This study aimed to report analytical data on total mercury levels in several fish species for the first time in thirty years and to also made individuals aware of the presence and danger from exposure to mercury through fish consumption. Fish samples were selected from local Lebanese markets and fisheries and included 94 samples of which were fresh, frozen, processed, and canned fish. All values were reported as microgram of mercury per gram of fish based on wet weight. The level of mercury ranged from 0.0190 to 0.5700 microg/g in fresh samples, 0.0059 to 0.0665 microg/g in frozen samples, and 0.0305 to 0.1190 microg/g in canned samples. The data clearly showed that higher levels of mercury were detected in local fresh fish as opposed to other types thus placing consumers at higher risk from mercury exposure. Moreover, the data revealed that Mallifa (yellowstripe barracuda/Sphyraena chrysotaenia), Sargous (white seabream/Diplodus sargus), Ghobbos (bogue/Boops boops), and shrimp (Penaeus sp.) were among the types containing the highest amounts of mercury. On the other hand, processed fish such as fish fillet, fish burger, small shrimp and crab are found to contain lower levels of mercury and are associated with lower exposure risks to mercury. Lebanese population should therefore, be aware to consume limited amounts of fresh local fish to minimize exposure to mercury.
High-density grids for efficient data collection from multiple crystals
Baxter, Elizabeth L.; Aguila, Laura; Alonso-Mori, Roberto; ...
2015-11-03
Higher throughput methods to mount and collect data from multiple small and radiation-sensitive crystals are important to support challenging structural investigations using microfocus synchrotron beamlines. Furthermore, efficient sample-delivery methods are essential to carry out productive femtosecond crystallography experiments at X-ray free-electron laser (XFEL) sources such as the Linac Coherent Light Source (LCLS). To address these needs, a high-density sample grid useful as a scaffold for both crystal growth and diffraction data collection has been developed and utilized for efficient goniometer-based sample delivery at synchrotron and XFEL sources. A single grid contains 75 mounting ports and fits inside an SSRL cassettemore » or uni-puck storage container. The use of grids with an SSRL cassette expands the cassette capacity up to 7200 samples. Grids may also be covered with a polymer film or sleeve for efficient room-temperature data collection from multiple samples. New automated routines have been incorporated into theBlu-Ice/DCSSexperimental control system to support grids, including semi-automated grid alignment, fully automated positioning of grid ports, rastering and automated data collection. Specialized tools have been developed to support crystallization experiments on grids, including a universal adaptor, which allows grids to be filled by commercial liquid-handling robots, as well as incubation chambers, which support vapor-diffusion and lipidic cubic phase crystallization experiments. Experiments in which crystals were loaded into grids or grown on grids using liquid-handling robots and incubation chambers are described. As a result, crystals were screened at LCLS-XPP and SSRL BL12-2 at room temperature and cryogenic temperatures.« less
Exploring Managerial Commitment towards SPI in Small and Very Small Enterprises
NASA Astrophysics Data System (ADS)
O'Connor, Rory V.; Basri, Shuib; Coleman, Gerry
This paper compares and contrasts the results of two similar studies into the software process practices in Irish Small and Very Small Enterprises. The first study contains rich findings in relation to the role and influence of managerial experience and style, with particular respect to the company founder and software development managers in small to medium seized enterprises (SMEs), whilst the second study contains extensive findings in relation to people and management involvement / commitment and SPI goal planning in very small enterprises (VSEs). By combining these results of these two studies of Irish SMEs/VSEs we can develop a rich picture of managerial commitment towards SPI and in particular explore the similarities between Small and Very Small Enterprises.
Experience of the Small Grower
Emmett Jordon
2002-01-01
The small grower cannot afford costly facilities, equipment, or containers. The grower usually does about everything by hand and gets help from family members and friends to get started. I describe the approach I use to produce longleaf pine container stock.
NASA Technical Reports Server (NTRS)
1990-01-01
The separation of fluid phases in microgravity environments is of importance to environmental control and life support systems (ECLSS) and materials processing in space. A successful fluid phase separation experiment will demonstrate a proof of concept for the separation technique and add to the knowledge base of material behavior. The phase separation experiment will contain a premixed fluid that will be exposed to a microgravity environment. After the phase separation of the compound has occurred, small samples of each of the species will be taken for analysis on Earth. By correlating the time of separation and the temperature history of the fluid, it will be possible to characterize the process. The phase separation experiment is totally self-contained, with three levels of containment on all fluids, and provides all necessary electrical power and control. The controller regulates the temperature of the fluid and controls data logging and sampling. An astronaut-activated switch will initiate the experiment and an unmaskable interrupt is provided for shutdown. The experiment has been integrated into space available on a manifested Get Away Special (GAS) experiment, CONCAP 2, part of the Consortium for Materials Complex Autonomous Payload (CAP) Program, scheduled for STS 42 in April 1991. Presented here are the design and the production of a fluid phase separation experiment for rapid implementation at low cost.
Plumlee, Geoffrey S.; Meeker, Gregory P.; Lovelace, John K.; Rosenbauer, Robert J.; Lamothe, Paul J.; Furlong, Edward T.; Demas, Charles R.
2006-01-01
Introduction: The flooding in the greater New Orleans area that resulted from Hurricanes Katrina and Rita in September, 2005, left behind accumulations of sediments up to many centimeters thick on streets, lawns, parking lots, and other flat surfaces. These flood sediment deposits have been the focus of extensive study by the US Environmental Protection Agency (EPA) and Louisiana Department of Environmental Quality (LDEQ) due to concerns that the sediments may contain elevated levels of heavy metals, organic contaminants, and microbes. The U.S. Geological Survey (USGS) is characterizing a limited number of flood sediment samples that were collected on September 15-16 and October 6-7, 2005, from the greater New Orleans area by personnel from the USGS Louisiana Water Science Center in Baton Rouge. Small samples (< 3 pints each) of wet to dry flood sediment were collected from 11 localities around downtown New Orleans on September 15, 2005, and two large samples (40 pints each) of wet flood sediment were collected from the Chalmette area on September 16. Twelve additional samples (8-10 pints each) were collected from New Orleans, Slidell, Rigolets, and Violet on October 6 and 7. The USGS characterization studies of these flood sediments are designed to produce data and interpretations regarding how the sediments and any contained contaminants may respond to environmental processes. This information will be of use to cleanup managers and DoI/USGS scientists assessing environmental impacts of the hurricanes and subsequent cleanup activities.
Leaded electronic waste is a possible source material for lead-contaminated jewelry.
Weidenhamer, Jeffrey D; Clement, Michael L
2007-10-01
Highly leaded jewelry, often imported from China, remains widely available in the United States. Leaded electronic waste is exported from the United States to several Asian countries where solder is recovered and circuit boards are stripped of parts in small workshops. To assess whether electronic waste is being recycled into the jewelry, lead, tin and copper content of highly leaded jewelry samples were determined by atomic absorption spectrometry. Sixteen jewelry items previously determined to contain 20-80% lead by weight were analyzed. Samples were digested in nitric acid for analysis of lead and copper, and in aqua regia for analysis of tin. Six samples contained significant amounts of tin, from 20.8% to 29.9% by weight. In addition, copper was a significant minor component of five of these samples (up to 4% by weight). Copper (present at 10-40% by weight in circuit boards) was shown to rapidly move into heated lead-tin solder. The combined lead-tin-copper content of these six items ranges from 93.5% to 100%, suggestive of a solder-based source material. These results are consistent with the hypothesis that recycled circuit board solders are being used to produce some of the heavily leaded imported jewelry sold in the United States. Should this hypothesis be substantiated, it suggests that environmental policies to protect children's health must address both proper recycling of source materials as well as restrictions of the lead content in consumer goods.
Grimmer, G; Dettbarn, G; Brune, H; Deutsch-Wenzel, R; Misfeld, J
1982-01-01
The purpose of this investigation was to identify the substances mainly responsible for the carcinogenic effect of used engine oil from gasoline engines using topical application as a carcinogen-specific bioassay. This was performed by comparison of the tumorigenic effect of single fractions with that of an unseparated sample of the lubricating oil. The probit analysis of the results shows: 1) The used engine oil, from gasoline-driven automobiles, investigated provoked local tumors after long-term application to the dorsal skin of mice. The incidence of carcinoma depended on the dose of the oil. 2) The fraction of the polycyclic aromatic hydrocarbons (PAH) containing more than three rings accounts for about 70% of the total carcinogenicity in the case of crankcase oil. This fraction constitutes only up to 1.14% by weight of the total oil sample. 3) The content of benzo(a)pyrene (216.8 mg/kg) accounts for 18% of the total carcinogenicity of the used oil. 4) Regarding the reduced carcinogenicity of the oil sample, which was reconstituted from all fractions, it seems possible that some of the carcinogenic substances were lost due to volatility, with evaporation of the solvents from the oil-fractionation processes. 5) Regarding the small effect of the PAH-free fraction, as well as the equal carcinogenic effects of the PAH-fraction (containing more than three rings) and the reconstituted oil sample, no hints for a co-carcinogenic activity were obtained.
DOE-2 sample run book: Version 2.1E
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winkelmann, F.C.; Birdsall, B.E.; Buhl, W.F.
1993-11-01
The DOE-2 Sample Run Book shows inputs and outputs for a variety of building and system types. The samples start with a simple structure and continue to a high-rise office building, a medical building, three small office buildings, a bar/lounge, a single-family residence, a small office building with daylighting, a single family residence with an attached sunspace, a ``parameterized`` building using input macros, and a metric input/output example. All of the samples use Chicago TRY weather. The main purpose of the Sample Run Book is instructional. It shows the relationship of LOADS-SYSTEMS-PLANT-ECONOMICS inputs, displays various input styles, and illustrates manymore » of the basic and advanced features of the program. Many of the sample runs are preceded by a sketch of the building showing its general appearance and the zoning used in the input. In some cases we also show a 3-D rendering of the building as produced by the program DrawBDL. Descriptive material has been added as comments in the input itself. We find that a number of users have loaded these samples onto their editing systems and use them as ``templates`` for creating new inputs. Another way of using them would be to store various portions as files that can be read into the input using the {number_sign}{number_sign} include command, which is part of the Input Macro feature introduced in version DOE-2.lD. Note that the energy rate structures here are the same as in the DOE-2.lD samples, but have been rewritten using the new DOE-2.lE commands and keywords for ECONOMICS. The samples contained in this report are the same as those found on the DOE-2 release files. However, the output numbers that appear here may differ slightly from those obtained from the release files. The output on the release files can be used as a check set to compare results on your computer.« less
Madsen, René Bjerregaard; Jensen, Mads Mørk; Mørup, Anders Juul; Houlberg, Kasper; Christensen, Per Sigaard; Klemmer, Maika; Becker, Jacob; Iversen, Bo Brummerstedt; Glasius, Marianne
2016-03-01
Hydrothermal liquefaction is a promising technique for the production of bio-oil. The process produces an oil phase, a gas phase, a solid residue, and an aqueous phase. Gas chromatography coupled with mass spectrometry is used to analyze the complex aqueous phase. Especially small organic acids and nitrogen-containing compounds are of interest. The efficient derivatization reagent methyl chloroformate was used to make analysis of the complex aqueous phase from hydrothermal liquefaction of dried distillers grains with solubles possible. A circumscribed central composite design was used to optimize the responses of both derivatized and nonderivatized analytes, which included small organic acids, pyrazines, phenol, and cyclic ketones. Response surface methodology was used to visualize significant factors and identify optimized derivatization conditions (volumes of methyl chloroformate, NaOH solution, methanol, and pyridine). Twenty-nine analytes of small organic acids, pyrazines, phenol, and cyclic ketones were quantified. An additional three analytes were pseudoquantified with use of standards with similar mass spectra. Calibration curves with high correlation coefficients were obtained, in most cases R (2) > 0.991. Method validation was evaluated with repeatability, and spike recoveries of all 29 analytes were obtained. The 32 analytes were quantified in samples from the commissioning of a continuous flow reactor and in samples from recirculation experiments involving the aqueous phase. The results indicated when the steady-state condition of the flow reactor was obtained and the effects of recirculation. The validated method will be especially useful for investigations of the effect of small organic acids on the hydrothermal liquefaction process.
Koulaxouzidis, Georgios; Karagkiouzis, Grigorios; Konstantinou, Marios; Gkiozos, Ioannis; Syrigos, Konstantinos
2013-04-22
The extent of mediastinal lymph node assessment during surgery for non-small cell cancer remains controversial. Different techniques are used, ranging from simple visual inspection of the unopened mediastinum to an extended bilateral lymph node dissection. Furthermore, different terms are used to define these techniques. Sampling is the removal of one or more lymph nodes under the guidance of pre-operative findings. Systematic (full) nodal dissection is the removal of all mediastinal tissue containing the lymph nodes systematically within anatomical landmarks. A Medline search was conducted to identify articles in the English language that addressed the role of mediastinal lymph node resection in the treatment of non-small cell lung cancer. Opinions as to the reasons for favoring full lymphatic dissection include complete resection, improved nodal staging and better local control due to resection of undetected micrometastasis. Arguments against routine full lymphatic dissection are increased morbidity, increase in operative time, and lack of evidence of improved survival. For complete resection of non-small cell lung cancer, many authors recommend a systematic nodal dissection as the standard approach during surgery, and suggest that this provides both adequate nodal staging and guarantees complete resection. Whether extending the lymph node dissection influences survival or recurrence rate is still not known. There are valid arguments in favor in terms not only of an improved local control but also of an improved long-term survival. However, the impact of lymph node dissection on long-term survival should be further assessed by large-scale multicenter randomized trials.
Bhargav, K K; Ram, S; Majumder, S B
2012-04-01
Nanocrystallites La0.8Pb0.2(Fe0.8Co0.2)O3 (LPFC) when bonded through a surface layer (carbon) in small ensembles display surface sensitive magnetism useful for biological probes, electrodes, and toxic gas sensors. A simple dispersion and hydrolysis of the salts in ethylene glycol (EG) in water is explored to form ensembles of the nanocrystallites (NCs) by combustion of a liquid precursor gel slowly in microwave at 70-80 dgrees C (apparent) in a closed container in air. In a dilute sample, the EG molecules mediate hydrolyzed species to configure in small groups in process to form a gel. Proposed models describe how a residual carbon bridges a stable bonded layer of a graphene-oxide-like hybrid structure on the LPFC-NCs in attenuating the magnetic structure. SEM images, measured from a pelletized sample which was used to study the gas sensing features in terms of the electrical resistance, describe plate shaped NCs, typically 30-60 nm widths, 60-180 nm lengths and -50 m2/g surface area (after heating at -750 degrees C). These NCs are arranged in ensembles (200-900 nm size). As per the X-ray diffraction, the plates (a Pnma orthorhombic structure) bear only small strain -0.0023 N/m2 and oxygen vacancies. The phonon and electronic bands from a bonded surface layer disappear when it is etched out slowly by heating above 550 degrees C in air. The surface layer actively promotes selective H2 gas sensor properties.
Quantitative determination of mycotoxins in urine by LC-MS/MS.
Ahn, J; Kim, D; Kim, H; Jahng, K-Y
2010-12-01
Naturally occurring mycotoxins are responsible for a wide array of adverse health effects. The measurement of urinary mycotoxin levels is a useful means of assessing an individual's exposure, but the development of sensitive and accurate analytical methods for detecting mycotoxins and their metabolites in urine samples is challenging. Urinary mycotoxins are present in low pg ml⁻¹ concentrations, and the chromatographic identification of their metabolites can be obscured by other endogenous metabolites. We developed an analytical method focused on the selection of two appropriate multiple-reaction monitoring transition for unambiguous identification and quantification of carcinogenic aflatoxin M₁ (AFM₁), ochratoxin A (OTA) and fumonisin B₁, B₂ (FB₁, FB₂) in urine samples from a small volunteer group in a pilot study. AFM₁, OTA, FB₁ and FB₂ were concentrated selectively, interfering substances were removed using an immunoaffinity column (IAC), and mycotoxins were measured using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in combination with a stable-isotope standard-dilution assay (SIDA). The method was sensitive enough to measure mycotoxins and their metabolites at pg ml⁻¹ levels in urine. The combination of LC-MS/MS and SIDA was critical to distinguishing pseudo-OTα interference from genuine OTα. Twelve urine samples contained OTA ranging from 0.013 to 0.093 ng ml⁻¹ (mean = 0.031 ng ml⁻¹). AFM₁ were detected in one sample at a 0.002 ng ml⁻¹ level, while FB₁ and FB₂ were undetectable in all 12 samples. None of the samples in this pilot study contained a detectable level of OTα, despite the presence of OTA, and this may suggest the need for further epidemiological investigation of OTA exposure in the Korean population.
Determination of beta activity in water
Barker, F.B.; Robinson, B.P.
1963-01-01
Many elements have one or more naturally radioactive isotopes, and several hundred other radionuclides have been produced artificially. Radioactive substances may be present in natural water as a result of geochemical processes or the release of radioactive waste and other nuclear debris to the environment. The Geological Survey has developed methods for measuring certain of these .radioactive substances in water. Radioactive substances often are present in water samples in microgram quantities or less. Therefore, precautions must be taken to prevent loss of material and to assure that the sample truly represents its source at the time of collection. Addition of acids, complexing agents, or stable isotopes often aids in preventing loss of radioactivity on container walls, on sediment, or on other solid materials in contact with the sample. The disintegration of radioactive atoms is a random process subject to established methods of statistical analysis. Because many water samples contain small amounts of radioactivity, low-level counting techniques must be used. The usual assumption that counting data follow a Gaussian distribution is invalid under these conditions, and statistical analyses must be based on the Poisson distribution. The gross beta activity in water samples is determined from the residue left after evaporation of the sample to dryness. Evaporation is accomplished first in a teflon dish, then the residue is transferred with distilled water to a counting planchet and again is reduced to dryness. The radioactivity on the planchet is measured with an anticoincidence-shielded, low-background, beta counter and is compared with measurements of a strontium-90-yttrium-90 standard prepared and measured in the same manner. Control charts are used to assure consistent operation of the counting instrument.
Kuroda, Noritaka; Hird, Nick; Cork, David G
2006-01-01
During further improvement of a high-throughput, solution-phase synthesis system, new workup tools and apparatus for parallel liquid-liquid extraction and evaporation have been developed. A combination of in-house design and collaboration with external manufacturers has been used to address (1) environmental issues concerning solvent emissions and (2) sample tracking errors arising from manual intervention. A parallel liquid-liquid extraction unit, containing miniature high-speed magnetic stirrers for efficient mixing of organic and aqueous phases, has been developed for use on a multichannel liquid handler. Separation of the phases is achieved by dispensing them into a newly patented filter tube containing a vertical hydrophobic porous membrane, which allows only the organic phase to pass into collection vials positioned below. The vertical positioning of the membrane overcomes the hitherto dependence on the use of heavier-than-water, bottom-phase, organic solvents such as dichloromethane, which are restricted due to environmental concerns. Both small (6-mL) and large (60-mL) filter tubes were developed for parallel phase separation in library and template synthesis, respectively. In addition, an apparatus for parallel solvent evaporation was developed to (1) remove solvent from the above samples with highly efficient recovery and (2) avoid the movement of individual samples between their collection on a liquid handler and registration to prevent sample identification errors. The apparatus uses a diaphragm pump to achieve a dynamic circulating closed system with a heating block for the rack of 96 sample vials and an efficient condenser to trap the solvents. Solvent recovery is typically >98%, and convenient operation and monitoring has made the apparatus the first choice for removal of volatile solvents.
Fukuda, Masakazu; Moriyama, Chifumi; Yamazaki, Tadao; Imaeda, Yoshimi; Koga, Akiko
2015-12-01
To investigate the relationship between viscosity of concentrated MAb solutions and particle size parameters obtained from small-angle X-ray scattering (SAXS). The viscosity of three MAb solutions (MAb1, MAb2, and MAb3; 40-200 mg/mL) was measured by electromagnetically spinning viscometer. The protein interactions of MAb solutions (at 60 mg/mL) was evaluated by SAXS. The phase behavior of 60 mg/mL MAb solutions in a low-salt buffer was observed after 1 week storage at 25°C. The MAb1 solutions exhibited the highest viscosity among the three MAbs in the buffer containing 50 mM NaCl. Viscosity of MAb1 solutions decreased with increasing temperature, increasing salt concentration, and addition of amino acids. Viscosity of MAb1 solutions was lowest in the buffer containing histidine, arginine, and aspartic acid. Particle size parameters obtained from SAXS measurements correlated very well with the viscosity of MAb solutions at 200 mg/mL. MAb1 exhibited liquid-liquid phase separation at a low salt concentration. Simultaneous addition of basic and acidic amino acids effectively suppressed intermolecular attractive interactions and decreased viscosity of MAb1 solutions. SAXS can be performed using a small volume of samples; therefore, the particle size parameters obtained from SAXS at intermediate protein concentration could be used to screen for low viscosity antibodies in the early development stage.
NASA Astrophysics Data System (ADS)
Okazaki, Ryuji; Sawada, Hirotaka; Yamanouchi, Shinji; Tachibana, Shogo; Miura, Yayoi N.; Sakamoto, Kanako; Takano, Yoshinori; Abe, Masanao; Itoh, Shoichi; Yamada, Keita; Yabuta, Hikaru; Okamoto, Chisato; Yano, Hajime; Noguchi, Takaaki; Nakamura, Tomoki; Nagao, Keisuke
2017-07-01
The spacecraft Hayabusa2 was launched on December 3, 2014, to collect and return samples from a C-type asteroid, 162173 Ryugu (provisional designation, 1999 JU3). It is expected that the samples collected contain organic matter and water-bearing minerals and have key information to elucidate the origin and history of the Solar System and the evolution of bio-related organics prior to delivery to the early Earth. In order to obtain samples with volatile species without terrestrial contamination, based on lessons learned from the Hayabusa mission, the sample catcher and container of Hayabusa2 were refined from those used in Hayabusa. The improvements include (1) a mirror finish of the inner wall surface of the sample catcher and the container, (2) adoption of an aluminum metal sealing system, and (3) addition of a gas-sampling interface for gas collection and evacuation. The former two improvements were made to limit contamination of the samples by terrestrial atmosphere below 1 Pa after the container is sealed. The gas-sampling interface will be used to promptly collect volatile species released from the samples in the sample container after sealing of the container. These improvements maintain the value of the returned samples.
Small Body Exploration Technologies as Precursors for Interstellar Robotics
NASA Astrophysics Data System (ADS)
Noble, R. J.; Sykes, M. V.
The scientific activities undertaken to explore our Solar System will be very similar to those required someday at other stars. The systematic exploration of primitive small bodies throughout our Solar System requires new technologies for autonomous robotic spacecraft. These diverse celestial bodies contain clues to the early stages of the Solar System's evolution, as well as information about the origin and transport of water-rich and organic material, the essential building blocks for life. They will be among the first objects studied at distant star systems. The technologies developed to address small body and outer planet exploration will form much of the technical basis for designing interstellar robotic explorers. The Small Bodies Assessment Group, which reports to NASA, initiated a Technology Forum in 2011 that brought together scientists and technologists to discuss the needs and opportunities for small body robotic exploration in the Solar System. Presentations and discussions occurred in the areas of mission and spacecraft design, electric power, propulsion, avionics, communications, autonomous navigation, remote sensing and surface instruments, sampling, intelligent event recognition, and command and sequencing software. In this paper, the major technology themes from the Technology Forum are reviewed, and suggestions are made for developments that will have the largest impact on realizing autonomous robotic vehicles capable of exploring other star systems.
Small Body Exploration Technologies as Precursors for Interstellar Robotics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Noble, Robert; /SLAC; Sykes, Mark V.
The scientific activities undertaken to explore our Solar System will be the same as required someday at other stars. The systematic exploration of primitive small bodies throughout our Solar System requires new technologies for autonomous robotic spacecraft. These diverse celestial bodies contain clues to the early stages of the Solar System's evolution as well as information about the origin and transport of water-rich and organic material, the essential building blocks for life. They will be among the first objects studied at distant star systems. The technologies developed to address small body and outer planet exploration will form much of themore » technical basis for designing interstellar robotic explorers. The Small Bodies Assessment Group, which reports to NASA, initiated a Technology Forum in 2011 that brought together scientists and technologists to discuss the needs and opportunities for small body robotic exploration in the Solar System. Presentations and discussions occurred in the areas of mission and spacecraft design, electric power, propulsion, avionics, communications, autonomous navigation, remote sensing and surface instruments, sampling, intelligent event recognition, and command and sequencing software. In this paper, the major technology themes from the Technology Forum are reviewed, and suggestions are made for developments that will have the largest impact on realizing autonomous robotic vehicles capable of exploring other star systems.« less
3D reconstruction of carbon nanotube networks from neutron scattering experiments
Mahdavi, Mostafa; Baniassadi, Majid; Baghani, Mostafa; ...
2015-09-03
Structure reconstruction from statistical descriptors, such as scattering data obtained using x-rays or neutrons, is essential in understanding various properties of nanocomposites. Scattering based reconstruction can provide a realistic model, over various length scales, that can be used for numerical simulations. In this study, 3D reconstruction of a highly loaded carbon nanotube (CNT)-conducting polymer system based on small and ultra-small angle neutron scattering (SANS and USANS, respectively) data was performed. These light-weight and flexible materials have recently shown great promise for high-performance thermoelectric energy conversion, and their further improvement requires a thorough understanding of their structure-property relationships. The first stepmore » in achieving such understanding is to generate models that contain the hierarchy of CNT networks over nano and micron scales. The studied system is a single walled carbon nanotube (SWCNT)/poly (3,4-ethylenedioxythiophene): poly (styrene sulfonate) (PEDOT: PSS). SANS and USANS patterns of the different samples containing 10, 30, and 50 wt% SWCNTs were measured. These curves were then utilized to calculate statistical two-point correlation functions of the nanostructure. These functions along with the geometrical information extracted from SANS data and scanning electron microscopy images were used to reconstruct a representative volume element (RVE) nanostructure. Generated RVEs can be used for simulations of various mechanical and physical properties. This work, therefore, introduces a framework for the reconstruction of 3D RVEs of high volume faction nanocomposites containing high aspect ratio fillers from scattering experiments.« less
3D reconstruction of carbon nanotube networks from neutron scattering experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mahdavi, Mostafa; Baniassadi, Majid; Baghani, Mostafa
Structure reconstruction from statistical descriptors, such as scattering data obtained using x-rays or neutrons, is essential in understanding various properties of nanocomposites. Scattering based reconstruction can provide a realistic model, over various length scales, that can be used for numerical simulations. In this study, 3D reconstruction of a highly loaded carbon nanotube (CNT)-conducting polymer system based on small and ultra-small angle neutron scattering (SANS and USANS, respectively) data was performed. These light-weight and flexible materials have recently shown great promise for high-performance thermoelectric energy conversion, and their further improvement requires a thorough understanding of their structure-property relationships. The first stepmore » in achieving such understanding is to generate models that contain the hierarchy of CNT networks over nano and micron scales. The studied system is a single walled carbon nanotube (SWCNT)/poly (3,4-ethylenedioxythiophene): poly (styrene sulfonate) (PEDOT: PSS). SANS and USANS patterns of the different samples containing 10, 30, and 50 wt% SWCNTs were measured. These curves were then utilized to calculate statistical two-point correlation functions of the nanostructure. These functions along with the geometrical information extracted from SANS data and scanning electron microscopy images were used to reconstruct a representative volume element (RVE) nanostructure. Generated RVEs can be used for simulations of various mechanical and physical properties. This work, therefore, introduces a framework for the reconstruction of 3D RVEs of high volume faction nanocomposites containing high aspect ratio fillers from scattering experiments.« less