Sample records for samples including tap

  1. Acanthamoeba keratitis: the role of domestic tap water contamination in the United Kingdom.

    PubMed

    Kilvington, Simon; Gray, Trevor; Dart, John; Morlet, Nigel; Beeching, John R; Frazer, David G; Matheson, Melville

    2004-01-01

    The incidence of acanthamoeba keratitis (AK) in the UK is some 15 times that in the United States and seven times that in Holland. To investigate reasons for this higher frequency, a study of the role of domestic tap water as a potential source of AK was undertaken. Tap outlets from the homes of 27 patients with culture-proven AK were sampled and cultured for free-living amoebae (FLA). For all Acanthamoeba isolates, mitochondrial DNA (mtDNA) restriction fragment length polymorphisms (RFLPs) and cytochrome oxidase (cox 1/2) sequence typing was performed to determine the similarity between corneal and tap water isolates. FLA, including Acanthamoeba, were isolated from 24 (89%) of 27 homes, and the presence within the homes varied significantly with tap water temperature and location: 19 (76%) of 25 bathroom sink cold taps sampled compared with 6 (24%) of 25 hot and 9 (47%) of 19 kitchen cold taps compared with 3 (16%) of 19 of hot kitchen taps. Acanthamoeba were isolated from 8 (30%) of 27 homes (five bathroom sink cold taps, one cloakroom cold tap, one bath, and one bedroom sink mixer [hot/cold] taps). In six cases, identical Acanthamoeba mtDNA profiles were found for the clinical and home tap water isolates. In keeping with UK plumbing practice, 24 of 27 homes had internal roof water storage tanks to supply domestic taps, but the mains fed the kitchen cold tap. Water storage tanks promote colonization of domestic water with FLA, including Acanthamoeba, and hence increase the risk of AK. This accounts for the significantly greater incidence of AK in the UK and supports advice to avoid using tap water in contact lens care routines.

  2. Levels of major and trace elements, including rare earth elements, and ²³⁸U in Croatian tap waters.

    PubMed

    Fiket, Željka; Rožmarić, Martina; Krmpotić, Matea; Benedik, Ljudmila

    2015-05-01

    Concentrations of 46 elements, including major, trace, and rare earth elements, and (238)U in Croatian tap waters were investigated. Selected sampling locations include tap waters from various hydrogeological regions, i.e., different types of aquifers, providing insight into the range of concentrations of studied elements and (238)U activity concentrations in Croatian tap waters. Obtained concentrations were compared with the Croatian maximum contaminant levels for trace elements in water intended for human consumption, as well as WHO and EPA drinking water standards. Concentrations in all analyzed tap waters were found in accordance with Croatian regulations, except tap water from Šibenik in which manganese in concentration above maximum permissible concentration (MPC) was measured. Furthermore, in tap water from Osijek, levels of arsenic exceeded the WHO guidelines and EPA regulations. In general, investigated tap waters were found to vary considerably in concentrations of studied elements, including (238)U activity concentrations. Causes of variability were further explored using statistical methods. Composition of studied tap waters was found to be predominately influenced by hydrogeological characteristics of the aquifer, at regional and local level, the existing redox conditions, and the household plumbing system. Rare earth element data, including abundances and fractionation patterns, complemented the characterization and facilitated the interpretation of factors affecting the composition of the analyzed tap waters.

  3. Analysis of organophosphate hydraulic fluids in U.S. Air force base soils

    PubMed

    David; Seiber

    1999-04-01

    Tri-aryl and tri-alkyl organophosphates (TAPs) have been used extensively as flame-retardant hydraulic fluids and fluid additives in commercial and military aircraft. Up to 80% of the consumption of these fluids has been estimated to be lost to unrecovered leakage. Tri-aryl phosphate components of these fluids are resistant to volatilization and solubilization in water, thus, their primary environmental fate pathway is sorption to soils. Environmental audits of military air bases generally do not include quantification of these compounds in soils. We have determined the presence and extent of TAP contamination in soil samples from several U.S. Air Force bases. Soils were collected, extracted, and analyzed using GC/FPD and GC/MS. Tricresyl phosphate was the most frequently found TAP in soil, ranging from 0.02 to 130 ppm. Other TAPs in soils included triphenyl phosphate and isopropylated triphenyl phosphate. Observations are made regarding the distribution, typical concentrations, persistence, and need for further testing of TAPs in soils at military installations. Additionally, GC and mass spectral data for these TAPs are presented, along with methods for their extraction, sample clean-up, and quantification.

  4. Effectiveness of Modal Decomposition for Tapping Atomic Force Microscopy Microcantilevers in Liquid Environment.

    PubMed

    Kim, Il Kwang; Lee, Soo Il

    2016-05-01

    The modal decomposition of tapping mode atomic force microscopy microcantilevers in liquid environments was studied experimentally. Microcantilevers with different lengths and stiffnesses and two sample surfaces with different elastic moduli were used in the experiment. The response modes of the microcantilevers were extracted as proper orthogonal modes through proper orthogonal decomposition. Smooth orthogonal decomposition was used to estimate the resonance frequency directly. The effects of the tapping setpoint and the elastic modulus of the sample under test were examined in terms of their multi-mode responses with proper orthogonal modes, proper orthogonal values, smooth orthogonal modes and smooth orthogonal values. Regardless of the stiffness of the microcantilever under test, the first mode was dominant in tapping mode atomic force microscopy under normal operating conditions. However, at lower tapping setpoints, the flexible microcantilever showed modal distortion and noise near the tip when tapping on a hard sample. The stiff microcantilever had a higher mode effect on a soft sample at lower tapping setpoints. Modal decomposition for tapping mode atomic force microscopy can thus be used to estimate the characteristics of samples in liquid environments.

  5. Microbiological evaluation of water during the 2011 flood crisis in Thailand.

    PubMed

    Chaturongkasumrit, Yuphakhun; Techaruvichit, Punnida; Takahashi, Hajime; Kimura, Bon; Keeratipibul, Suwimon

    2013-10-01

    In 2011, a severe flood occurred in Thailand, covering nearly half the country in water for several months. The contamination of floodwater and subsequent contamination of water for human consumption could have potentially led to a widespread health crisis. However, to date, no study has been conducted to determine the safety of the waters used for human consumption in Thailand during the severe flood. Therefore, we conducted microbiological analysis of 4 kinds of water (floodwater, river water, tap water, and filtered tap water) collected from industrial and residential areas that were damaged due to flooding. Higher net levels of bacteria were found in water with a higher turbidity. No clear trend was observed in the pH value of all 4 water samples. The level of total bacterial contamination in the water samples was estimated by real-time quantitative polymerase chain reaction (PCR). Eleven of the 12 tap water samples and all of the filtered tap water samples had a total bacterial load that exceeded the Thai water quality standards. One of the tap water samples and one of the filtered tap water samples were found to be positive for Shigella sp., although none of the floodwater samples showed detectable levels of this pathogen as determined by PCR analysis. One of the samples of floodwater was also found to be positive for Leptospira sp., but none of the tap water or filtered tap water samples were positive. Most of the tap water samples and all filtered tap water samples were found to be contaminated with Vibrio cholerae. Bacterial contamination in water samples was also analyzed by denaturing gradient gel electrophoresis (DGGE) analysis. These results revealed that several microorganisms were transferred via floodwater to different areas in the central part of Thailand and cross-contaminated between floodwater and water for human consumption. © 2013.

  6. [Volatile organic compounds of the tap water in the Watarase, Tone and Edo River system].

    PubMed

    Ohmichi, Kimihide; Ohmichi, Masayoshi; Machida, Kazuhiko

    2004-01-01

    The chlorination of river water in purification plants is known to produce carcinogens such as trihalomethanes (THMs). We studied the river system of the Watarase, Tone, and Edo Rivers in regard to the formation of THMs. This river system starts from the base of the Ashio copper mine and ends at Tokyo Bay. Along the rivers, there are 14 local municipalities in Gunma, Saitama, Ibaragi and Chiba Prefectures, as well as Tokyo. This area is the center of the Kanto plain and includes the main sources of water pollution from human activities. We also analyzed various chemicals in river water and tap water to clarify the status of the water environment, and we outline the problems of the water environment in the research area (Fig. 1). Water samples were taken from 18 river sites and 42 water faucets at public facilities in 14 local municipalities. We analyzed samples for volatile organic compounds such as THMs, by gas chromatography mass spectrometry (GC-MS), and evaluations of chemical oxygen demand (COD) were made with reference to Japanese drinking water quality standards. Concentrations of THMs in the downstream tap water samples were higher than those in the samples from the upperstream. This tendency was similar to the COD of the river water samples, but no correlation between the concentration of THMs in tap water and the COD in tap water sources was found. In tap water of local government C, trichloroethylene was detected. The current findings suggest that the present water filtration plant procedures are not sufficient to remove some hazardous chemicals from the source water. Moreover, it was confirmed that the water filtration produced THMs. Also, trichloroethylene was detected from the water environment in the research area, suggesting that pollution of the water environment continues.

  7. Bacteriological quality of bottled drinking water versus municipal tap water in Dharan municipality, Nepal.

    PubMed

    Pant, Narayan Dutt; Poudyal, Nimesh; Bhattacharya, Shyamal Kumar

    2016-06-07

    Water-related diseases are of great concern in developing countries like Nepal. Every year, there are countless morbidity and mortality due to the consumption of unsafe drinking water. Recently, there have been increased uses of bottled drinking water in an assumption that the bottled water is safer than the tap water and its use will help to protect from water-related diseases. So, the main objective of this study was to analyze the bacteriological quality of bottled drinking water and that of municipal tap water. A total of 100 samples (76 tap water and 24 bottled water) were analyzed for bacteriological quality and pH. The methods used were spread plate method for total plate count (TPC) and membrane filter method for total coliform count (TCC), fecal coliform count (FCC), and fecal streptococcal count (FSC). pH meter was used for measuring pH. One hundred percent of the tap water samples and 87.5 % of the bottled water samples were found to be contaminated with heterotrophic bacteria. Of the tap water samples, 55.3 % were positive for total coliforms, compared with 25 % of the bottled water. No bottled water samples were positive for fecal coliforms and fecal streptococci, in contrast to 21.1 % and 14.5 % of the tap water samples being contaminated with fecal coliforms and fecal streptococci, respectively. One hundred percent of the tap water samples and 54.2 % of the bottled water samples had pH in the acceptable range. All of the municipal tap water samples and most of the bottled drinking water samples distributed in Dharan municipality were found to be contaminated with one or more than one type of indicator organisms. On the basis of our findings, we may conclude that comparatively, the bottled drinking water may have been safer (than tap water) to drink.

  8. What's Wrong with the Tap? Examining Perceptions of Tap Water and Bottled Water at Purdue University

    NASA Astrophysics Data System (ADS)

    Saylor, Amber; Prokopy, Linda Stalker; Amberg, Shannon

    2011-09-01

    The environmental impacts of bottled water prompted us to explore drinking water choices at Purdue University, located in West Lafayette, IN. A random sample of 2,045 Purdue University students, staff, and faculty was invited to participate in an online survey. The survey assessed current behaviors as well as perceived barriers and benefits to drinking tap water versus bottled water. 677 surveys were completed for a response rate of 33.1%. We then conducted qualitative interviews with a purposive sample of university undergraduates ( n = 21) to obtain contextual insights into the survey results and the beliefs of individuals with a variety of drinking water preferences. This study revealed that women drink disproportionately more bottled water then men while undergraduate students drink more than graduate students, staff and faculty. The study also uncovered a widespread belief that recycling eliminates the environmental impacts of bottled water. Important barriers to drinking tap water at Purdue include: perceived risks from tap water and the perceived safety of bottled water, preferring the taste of bottled water, and the convenience of drinking bottled water. The qualitative interviews revealed that drinking water choices can be influenced by several factors—especially whether individuals trust tap water to be clean—but involve varying levels of complexity. The implications of these results for social marketing strategies to promote tap water are discussed.

  9. What's wrong with the tap? Examining perceptions of tap water and bottled water at Purdue University.

    PubMed

    Saylor, Amber; Prokopy, Linda Stalker; Amberg, Shannon

    2011-09-01

    The environmental impacts of bottled water prompted us to explore drinking water choices at Purdue University, located in West Lafayette, IN. A random sample of 2,045 Purdue University students, staff, and faculty was invited to participate in an online survey. The survey assessed current behaviors as well as perceived barriers and benefits to drinking tap water versus bottled water. 677 surveys were completed for a response rate of 33.1%. We then conducted qualitative interviews with a purposive sample of university undergraduates (n = 21) to obtain contextual insights into the survey results and the beliefs of individuals with a variety of drinking water preferences. This study revealed that women drink disproportionately more bottled water then men while undergraduate students drink more than graduate students, staff and faculty. The study also uncovered a widespread belief that recycling eliminates the environmental impacts of bottled water. Important barriers to drinking tap water at Purdue include: perceived risks from tap water and the perceived safety of bottled water, preferring the taste of bottled water, and the convenience of drinking bottled water. The qualitative interviews revealed that drinking water choices can be influenced by several factors-especially whether individuals trust tap water to be clean-but involve varying levels of complexity. The implications of these results for social marketing strategies to promote tap water are discussed.

  10. Drinking of tap water is smart, but how do it better? - A tap water quality research

    NASA Astrophysics Data System (ADS)

    Mika, Anna; Sekuła, Klaudia; Dendys, Marta; Ptaszek, Weronika; Postawa, Adam

    2018-02-01

    Drinking tap water has recently become popular. It is a way to fight with the tons of garbage (disposable, plastic bottles). However, many people are afraid of water quality. The research was performed in December 2015 in Krakow, during one week. 56 samples were collected. The samples were taken in different times of the day and in the two types of building (old one with installation from the 80s and new one with installation built in past few years). Samples were taken by two qualified operators. The first sample was collected at the morning at 6 a.m., before anyone uses the tap. The second one after the tap was flushed and then the third one after 30 minutes stagnation. At the evening was taken one sample (after using the tap all day).The aim of the research was to check the quality of drinking water in the end-user. The results show that quality of tap water in Krakow is good, also in the end-user, but the concentration of chemical elements are changing during the flushing and using of the tap.

  11. Survey of human pharmaceuticals in drinking water in the Czech Republic.

    PubMed

    Kozisek, Frantisek; Pomykacova, Ivana; Jeligova, Hana; Cadek, Vaclav; Svobodova, Veronika

    2013-03-01

    The first large-scale assessment of pharmaceuticals in drinking water in the Czech Republic (CR) focused on the detection of five substances. Samples were collected from public water systems supplying 5.3 million people, 50.5% of the Czech population. In the initial survey of tap water from 92 major supply zones using mostly surface water, no pharmaceutical exceeded the limit of quantification (LOQ = 0.5 ng/L). In a second survey, samples were collected from the outlet of 23 water treatment plants (WTPs) considered of high risk because they use surface waters influenced by wastewater. Ibuprofen was the most frequently found pharmaceutical (19 samples), followed by carbamazepine (12), naproxen (8), and diclofenac (3); concentrations ranged from 0.5 to 20.7 ng/L, with medians below 6 ng/L. Concentrations of 17α-ethinylestradiol were below the LOQ. A follow-up survey included tap and outlet samples from eight of the 23 WTPs with the highest concentrations. Pharmaceuticals were quantified in only three tap water samples. Regarding risks to consumers, these results suggest that a relatively small population (<10%) in the CR is exposed to quantifiable concentrations of pharmaceuticals in tap water and that an extremely high margin of safety (several thousand-fold to several million-fold) is associated with these exposures.

  12. Cultural and Molecular Evidence of Legionella spp. Colonization in Dental Unit Waterlines: Which Is the Best Method for Risk Assessment?

    PubMed

    Ditommaso, Savina; Giacomuzzi, Monica; Ricciardi, Elisa; Zotti, Carla M

    2016-02-06

    Legionella spp. are ubiquitous in aquatic habitats and water distribution systems, including dental unit waterlines (DUWLs). The aim of the present study was to determine the prevalence of Legionella in DUWLs and tap water samples using PMA-qPCR and standard culture methods. The total viable counts (TVCs) of aerobic heterotrophic bacteria in the samples were also determined. Legionella spp. were detected and quantified using the modified ISO 11731 culture method. Extracted genomic DNA was analysed using the iQ-Check Quanti Legionella spp. kit, and the TVCs were determined according to the ISO protocol 6222. Legionella spp. were detected in 100% of the samples using the PMA-qPCR method, whereas these bacteria were detected in only 7% of the samples using the culture method. The number of colony forming units (CFUs) of the TVCs in the DUWL and tap water samples differed, with the bacterial load being significantly lower in the tap water samples (p-value = 0). The counts obtained were within the Italian standard range established for potable water in only 5% of the DUWL water samples and in 77% of the tap water samples. Our results show that the level of Legionella spp. contamination determined using the culture method does not reflect the true scale of the problem, and consequently we recommend testing for the presence of aerobic heterotrophic bacteria based on the assumption that Legionella spp. are components of biofilms.

  13. Cultural and Molecular Evidence of Legionella spp. Colonization in Dental Unit Waterlines: Which Is the Best Method for Risk Assessment?

    PubMed Central

    Ditommaso, Savina; Giacomuzzi, Monica; Ricciardi, Elisa; Zotti, Carla M.

    2016-01-01

    Legionella spp. are ubiquitous in aquatic habitats and water distribution systems, including dental unit waterlines (DUWLs). The aim of the present study was to determine the prevalence of Legionella in DUWLs and tap water samples using PMA-qPCR and standard culture methods. The total viable counts (TVCs) of aerobic heterotrophic bacteria in the samples were also determined. Legionella spp. were detected and quantified using the modified ISO 11731 culture method. Extracted genomic DNA was analysed using the iQ-Check Quanti Legionella spp. kit, and the TVCs were determined according to the ISO protocol 6222. Legionella spp. were detected in 100% of the samples using the PMA-qPCR method, whereas these bacteria were detected in only 7% of the samples using the culture method. The number of colony forming units (CFUs) of the TVCs in the DUWL and tap water samples differed, with the bacterial load being significantly lower in the tap water samples (p-value = 0). The counts obtained were within the Italian standard range established for potable water in only 5% of the DUWL water samples and in 77% of the tap water samples. Our results show that the level of Legionella spp. contamination determined using the culture method does not reflect the true scale of the problem, and consequently we recommend testing for the presence of aerobic heterotrophic bacteria based on the assumption that Legionella spp. are components of biofilms. PMID:26861373

  14. The δ2H and δ18O of tap water from 349 sites in the United States and selected territories

    USGS Publications Warehouse

    Coplen, Tyler B.; Landwehr, Jurate M.; Qi, Haiping; Lorenz, Jennifer M.

    2013-01-01

    Because the stable isotopic compositions of hydrogen (δ2H) and oxygen (δ18O) of animal (including human) tissues, such as hair, nail, and urine, reflect the δ2H and δ18O of water and food ingested by an animal or a human and because the δ2H and δ18O of environmental waters vary geographically, δ2H and δ18O values of tap water samples collected in 2007-2008 from 349 sites in the United States and three selected U.S. territories have been measured in support of forensic science applications, creating one of the largest databases of tap water δ2H and δ18O values to date. The results of replicate isotopic measurements for these tap water samples confirm that the expanded uncertainties (U = 2μc) obtained over a period of years by the Reston Stable Isotope Laboratory from δ2H and δ18O dual-inlet mass spectrometric measurements are conservative, at ±2‰ and ±0.2 ‰, respectively. These uncertainties are important because U.S. Geological Survey data may be needed for forensic science applications, including providing evidence in court cases. Half way through the investigation, an isotope-laser spectrometer was acquired, enabling comparison of dual-inlet isotope-ratio mass spectrometric results with isotope-laser spectrometric results. The uncertainty of the laser-based δ2H measurement results for these tap water samples is comparable to the uncertainty of the mass spectrometric method, with the laser-based method having a slightly lower uncertainty. However, the δ18O uncertainty of the laser-based method is more than a factor of ten higher than that of the dual-inlet isotoperatio mass spectrometric method.

  15. Can technical, functional and structural characteristics of dental units predict Legionella pneumophila and Pseudomonas aeruginosa contamination?

    PubMed

    Aprea, Luigi; Cannova, Lucia; Firenze, Alberto; Bivona, Maria S; Amodio, Emanuele; Romano, Nino

    2010-12-01

    Legionella pneumophila and Pseudomonas aeruginosa are common colonizers of water environments, particularly dental unit waterlines. The aim of this study was to assess whether the technical, functional and structural characteristics of dental units can influence the presence and the levels of opportunistic pathogens. Overall, 42 water samples were collected from dental units in a teaching hospital in Palermo, Italy, including 21 samples from the 21 taps supplied by the municipal water distribution system and 21 samples from oral rinsing cups at 21 dental units. L. pneumophila was present in 16 out of 21 water samples (76.2%) from dental units, and the median concentration was higher in samples from oral rinsing cups than in those from taps (P < 0.001). P. aeruginosa was equally distributed in water samples collected from oral rinsing cups and from taps. Some characteristics of dental units (age, number of chairs per room, number of patients per day and water temperature) were slightly associated with the presence of P. aeruginosa, but not with contamination by L. pneumophila. Our experience suggests that L. pneumophila is frequently detected in dental units, as reported in previous studies, whereas P. aeruginosa is not a frequent contaminant. As a consequence, microbiological control of water quality should be routinely performed, and should include the detection of opportunistic pathogens when bacterial contamination is expected.

  16. 47 CFR 76.609 - Measurements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... either: (1) The manufacturer's specifications for subscriber tap isolation based on a representative sample of no less than 500 subscribers taps or (2) Laboratory tests performed by or for the operator of a cable television system on a representative sample of no less than 50 subscriber taps, indicates that...

  17. Fluid sampling tool

    DOEpatents

    Johnston, Roger G.; Garcia, Anthony R. E.; Martinez, Ronald K.

    2001-09-25

    The invention includes a rotatable tool for collecting fluid through the wall of a container. The tool includes a fluid collection section with a cylindrical shank having an end portion for drilling a hole in the container wall when the tool is rotated, and a threaded portion for tapping the hole in the container wall. A passageway in the shank in communication with at least one radial inlet hole in the drilling end and an opening at the end of the shank is adapted to receive fluid from the container. The tool also includes a cylindrical chamber affixed to the end of the shank opposite to the drilling portion thereof for receiving and storing fluid passing through the passageway. The tool also includes a flexible, deformable gasket that provides a fluid-tight chamber to confine kerf generated during the drilling and tapping of the hole. The invention also includes a fluid extractor section for extracting fluid samples from the fluid collecting section.

  18. A computer vision framework for finger-tapping evaluation in Parkinson's disease.

    PubMed

    Khan, Taha; Nyholm, Dag; Westin, Jerker; Dougherty, Mark

    2014-01-01

    The rapid finger-tapping test (RFT) is an important method for clinical evaluation of movement disorders, including Parkinson's disease (PD). In clinical practice, the naked-eye evaluation of RFT results in a coarse judgment of symptom scores. We introduce a novel computer-vision (CV) method for quantification of tapping symptoms through motion analysis of index-fingers. The method is unique as it utilizes facial features to calibrate tapping amplitude for normalization of distance variation between the camera and subject. The study involved 387 video footages of RFT recorded from 13 patients diagnosed with advanced PD. Tapping performance in these videos was rated by two clinicians between the symptom severity levels ('0: normal' to '3: severe') using the unified Parkinson's disease rating scale motor examination of finger-tapping (UPDRS-FT). Another set of recordings in this study consisted of 84 videos of RFT recorded from 6 healthy controls. These videos were processed by a CV algorithm that tracks the index-finger motion between the video-frames to produce a tapping time-series. Different features were computed from this time series to estimate speed, amplitude, rhythm and fatigue in tapping. The features were trained in a support vector machine (1) to categorize the patient group between UPDRS-FT symptom severity levels, and (2) to discriminate between PD patients and healthy controls. A new representative feature of tapping rhythm, 'cross-correlation between the normalized peaks' showed strong Guttman correlation (μ2=-0.80) with the clinical ratings. The classification of tapping features using the support vector machine classifier and 10-fold cross validation categorized the patient samples between UPDRS-FT levels with an accuracy of 88%. The same classification scheme discriminated between RFT samples of healthy controls and PD patients with an accuracy of 95%. The work supports the feasibility of the approach, which is presumed suitable for PD monitoring in the home environment. The system offers advantages over other technologies (e.g. magnetic sensors, accelerometers, etc.) previously developed for objective assessment of tapping symptoms. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Estimation of fluoride concentration in drinking water and common beverages in United Arab Emirates (UAE).

    PubMed

    Walia, Tarun; Abu Fanas, Salem; Akbar, Madiha; Eddin, Jamal; Adnan, Mohamad

    2017-07-01

    To assess fluoride concentration in drinking water which include tap water of 4 emirates - Abu Dhabi, Dubai, Sharjah and Ajman plus bottled water, commonly available soft drinks & juices in United Arab Emirates. Five different samples of tap water collected from each of the four emirates of UAE: Ajman, Sharjah, Abu Dhabi and Dubai; twenty-two brands of bottled water and fifteen brands of popular cold beverages, purchased from different supermarkets in U.A.E were tested using ion selective electrode method and the fluoride concentration was determined. The mean fluoride content of tap water samples was 0.14 mg F/L with a range of 0.04-0.3 mg F/L; with Ajman tap water samples showing the highest mean fluoride content of 0.3 mg F/L. The mean fluoride content for both bottled drinking water and beverages was 0.07 mg F/L with a range of 0.02-0.50 mg F/L and 0.04-0.1 mg F/L respectively. Majority (68.2%) of the bottled water are produced locally within U.A.E while a few (31.8%) are imported. The tap water, bottled water and beverages available in U.A.E show varying concentrations of fluoride, however none showed the optimal level necessary to prevent dental caries. Dental professionals in U.A.E should be aware of the fluoride concentrations before prescribing fluoride supplements to children.

  20. 40 CFR 141.80 - General requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and copper action levels measured in samples collected at consumers' taps. (c) Lead and copper action levels. (1) The lead action level is exceeded if the concentration of lead in more than 10 percent of tap... action level is exceeded if the concentration of copper in more than 10 percent of tap water samples...

  1. Evaluation on the Quality of Bangkok Tap Water with Other Drinking Purpose Water

    NASA Astrophysics Data System (ADS)

    Kordach, A.; Chardwattananon, C.; Wongin, K.; Chayaput, B.; Wongpat, N.

    2018-02-01

    The concern of drinking purposed water quality in Bangkok, Nonthaburi, and Samutprakarn provinces has been a problem for over fifteen years. Metropolitan Water Works Authority (MWA) of Thailand is fully responsible for providing water supply to the mentioned areas. The objective of Drinkable Tap Water Project is to make people realize in quality of tap water. Communities, school, government agencies, hotels, hospitals, department stores, and other organizations are participating in this project. MWA have collected at least 3 samples of water from the corresponding places and the samples have to meet the World Health Organization (WHO) guidelines level. This study is to evaluate water quality of tap water, storage water, filtered water, and filtered water dispenser. The water samples from 2,354 attending places are collected and analyzed. From October 2011 to September 2016, MWA analyzed 32,711 samples. The analyzed water parameters are free residual chlorine, appearance color, turbidity, pH, conductivity, total dissolved solids (TDS), and pathogenic bacteria; E.coli. The results indicated that a number of tap water samples had the highest number compliance with WHO guidelines levels at 98.40%. The filtered water, filtered water dispenser, and storage water were received 96.71%, 95.63%, and 90.88%, respectively. However, the several samples fail to pass WHO guideline level because they were contaminated by E.coli. The result is that tap water has the highest score among other sources probably because tap water has chlorine for disinfection and always is monitored by professional team round-the-clock services compared to the other water sources with less maintenance or cleaning. Also, water quality reports are continuously sent to customers by mail addresses. Tap water quality data are shown on MWA websites and Facebook. All these steps of work should enhance the confidence of tap water quality.

  2. Comparing microbial water quality in an intermittent and continuous piped water supply.

    PubMed

    Kumpel, Emily; Nelson, Kara L

    2013-09-15

    Supplying piped water intermittently is a common practice throughout the world that increases the risk of microbial contamination through multiple mechanisms. Converting an intermittent supply to a continuous supply has the potential to improve the quality of water delivered to consumers. To understand the effects of this upgrade on water quality, we tested samples from reservoirs, consumer taps, and drinking water provided by households (e.g. from storage containers) from an intermittent and continuous supply in Hubli-Dharwad, India, over one year. Water samples were tested for total coliform, Escherichia coli, turbidity, free chlorine, and combined chlorine. While water quality was similar at service reservoirs supplying the continuous and intermittent sections of the network, indicator bacteria were detected more frequently and at higher concentrations in samples from taps supplied intermittently compared to those supplied continuously (p < 0.01). Detection of E. coli was rare in continuous supply, with 0.7% of tap samples positive compared to 31.7% of intermittent water supply tap samples positive for E. coli. In samples from both continuously and intermittently supplied taps, higher concentrations of total coliform were measured after rainfall events. While source water quality declined slightly during the rainy season, only tap water from intermittent supply had significantly more indicator bacteria throughout the rainy season compared to the dry season. Drinking water samples provided by households in both continuous and intermittent supplies had higher concentrations of indicator bacteria than samples collected directly from taps. Most households with continuous supply continued to store water for drinking, resulting in re-contamination, which may reduce the benefits to water quality of converting to continuous supply. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Effect of Transversus Abdominis Plane Block on Postoperative Pain after Colorectal Surgery: A Meta-Analysis of Randomized Controlled Trials.

    PubMed

    Liu, Lin; Xie, Yan-Hu; Zhang, Wei; Chai, Xiao-Qing

    2018-01-01

    To assess the analgesic efficacy of transversus abdominis plane (TAP) block in patients undergoing colorectal surgery (CRS). The databases of PubMed, ISI Web of Science, and Embase were searched, and randomized controlled studies (RCTs) that compared TAP block to control for relief of postoperative pain in patients who underwent CRS were included. Outcomes, including postoperative pain at rest and with movement, morphine use, postoperative nausea and vomiting, and the length of hospital stay, were analyzed using STATA software. The weighted mean differences (WMDs) with 95% confidence intervals (95% CIs) or relative risk with 95% CI were used to present the strength of associations. A total of 7 RCTs with 511 patients were included. The results of this study suggested that TAP block significantly relieved postoperative pain during postanesthetic recovery after CRS at rest and during movement (WMDs were -0.98 [95% CI -1.57 to -0.38] and -0.68 [-1.07 to -0.30], respectively), and also decreased pain intensity during movement 24 h after CRS (WMD: -0.57 [95% CI -1.06 to -0.08]). TAP block significantly reduced opioid consumption within 24 h when compared to controls, with a WMD of 15.66 (95% CI -23.93 to -7.39). However, TAP block did not shorten the length of hospital stay. TAP block was an effective approach for relief of postoperative pain and reduced postoperative consumption of morphine. More RCTs with large sample sizes are required to confirm these findings. © 2018 The Author(s) Published by S. Karger AG, Basel.

  4. Legionella species diversity and dynamics from surface reservoir to tap water: from cold adaptation to thermophily

    PubMed Central

    Lesnik, René; Brettar, Ingrid; Höfle, Manfred G

    2016-01-01

    Water samples of the Drinking Water Supply System (DWSS) of the city of Braunschweig were analysed for its Legionella species composition using genus-specific PCR amplicons and single-strand conformation polymorphism (SSCP) fingerprint analyses based on 16S rRNA genes. These analyses comprised the whole supply chain including raw water, treatment process and large-scale storage, and a seasonal study of finished drinking water sampled monthly from cold and hot tap water. Treatment of raw water had a major impact on Legionella species by reducing their diversity and abundances. The Legionella species composition of the tap water was highly distinct from that of both source waters. In cold water, 8–14 different phylotypes of Legionella (PTLs) were observed per sample with relative abundances ranging from >1% to 53%. In hot water, L. pneumophila was present during all seasons at high relative abundances (8–40%) accompanied by 5–14 other PTLs of which 6 PTLs were in common with cold water. This thermophilic Legionella community, including L. pneumophila, was able to grow in the hot water above 50 °C. Such thermophilic Legionella populations are of general relevance for drinking water management and public health, but also for the ecology and evolution of the genus Legionella. PMID:26528838

  5. Legionella species diversity and dynamics from surface reservoir to tap water: from cold adaptation to thermophily.

    PubMed

    Lesnik, René; Brettar, Ingrid; Höfle, Manfred G

    2016-05-01

    Water samples of the Drinking Water Supply System (DWSS) of the city of Braunschweig were analysed for its Legionella species composition using genus-specific PCR amplicons and single-strand conformation polymorphism (SSCP) fingerprint analyses based on 16S rRNA genes. These analyses comprised the whole supply chain including raw water, treatment process and large-scale storage, and a seasonal study of finished drinking water sampled monthly from cold and hot tap water. Treatment of raw water had a major impact on Legionella species by reducing their diversity and abundances. The Legionella species composition of the tap water was highly distinct from that of both source waters. In cold water, 8-14 different phylotypes of Legionella (PTLs) were observed per sample with relative abundances ranging from >1% to 53%. In hot water, L. pneumophila was present during all seasons at high relative abundances (8-40%) accompanied by 5-14 other PTLs of which 6 PTLs were in common with cold water. This thermophilic Legionella community, including L. pneumophila, was able to grow in the hot water above 50 °C. Such thermophilic Legionella populations are of general relevance for drinking water management and public health, but also for the ecology and evolution of the genus Legionella.

  6. Thermal Analyzer for Planetary Soil (TAPS): an in Situ Instrument for Mineral and Volatile-element Measurements

    NASA Technical Reports Server (NTRS)

    Gooding, J. L.; Ming, D. W.; Gruener, J. E.; Gibbons, F. L.; Allton, J. H.

    1993-01-01

    Thermal Analyzer for Planetary Soil (TAPS) offers a specific implementation for the generic thermal analyzer/evolved-gas analyzer (TA/EGA) function included in the Mars Environmental Survey (MESUR) strawman payload; applications to asteroids and comets are also possible. The baseline TAPS is a single-sample differential scanning calorimeter (DSC), backed by a capacitive-polymer humidity sensor, with an integrated sampling mechanism. After placement on a planetary surface, TAPS acquires 10-50 mg of soil or sediment and heats the sample from ambient temperature to 1000-1300 K. During heating, DSC data are taken for the solid and evolved gases are swept past the water sensor. Through ground based data analysis, multicomponent DSC data are deconvolved and correlated with the water release profile to quantitatively determine the types and relative proportions of volatile-bearing minerals such as clays and other hydrates, carbonates, and nitrates. The rapid-response humidity sensors also achieve quantitative analysis of total water. After conclusion of soil-analysis operations, the humidity sensors become available for meteorology. The baseline design fits within a circular-cylindrical volume less than 1000 cm(sup 3), occupies 1.2 kg mass, and consumes about 2 Whr of power per analysis. Enhanced designs would acquire and analyze multiple samples and employ additional microchemical sensors for analysis of CO2, SO2, NO(x), and other gaseous species. Atmospheric pumps are also being considered as alternatives to pressurized purge gas.

  7. Thermal Analyzer for Planetary Soil (TAPS): an in situ instrument for mineral and volatile-element measurements

    NASA Astrophysics Data System (ADS)

    Gooding, J. L.; Ming, D. W.; Gruener, J. E.; Gibbons, F. L.; Allton, J. H.

    Thermal Analyzer for Planetary Soil (TAPS) offers a specific implementation for the generic thermal analyzer/evolved-gas analyzer (TA/EGA) function included in the Mars Environmental Survey (MESUR) strawman payload; applications to asteroids and comets are also possible. The baseline TAPS is a single-sample differential scanning calorimeter (DSC), backed by a capacitive-polymer humidity sensor, with an integrated sampling mechanism. After placement on a planetary surface, TAPS acquires 10-50 mg of soil or sediment and heats the sample from ambient temperature to 1000-1300 K. During heating, DSC data are taken for the solid and evolved gases are swept past the water sensor. Through ground based data analysis, multicomponent DSC data are deconvolved and correlated with the water release profile to quantitatively determine the types and relative proportions of volatile-bearing minerals such as clays and other hydrates, carbonates, and nitrates. The rapid-response humidity sensors also achieve quantitative analysis of total water. After conclusion of soil-analysis operations, the humidity sensors become available for meteorology. The baseline design fits within a circular-cylindrical volume less than 1000 cm3, occupies 1.2 kg mass, and consumes about 2 Whr of power per analysis. Enhanced designs would acquire and analyze multiple samples and employ additional microchemical sensors for analysis of CO2, SO2, NO(x), and other gaseous species. Atmospheric pumps are also being considered as alternatives to pressurized purge gas.

  8. Bacterial community of iron tubercles from a drinking water distribution system and its occurrence in stagnant tap water.

    PubMed

    Chen, Lu; Jia, Rui-Bao; Li, Li

    2013-07-01

    Bacteria in drinking water distribution systems can cause deterioration of the water quality, and the microbial quality of tap water is closely related to consumer health. In the present study, the potential effects of bacteria attached to cast iron pipes on tap water in a distribution system were investigated. Comparison of the bacterial community composition of pipe tubercles with that of stagnant tap water samples based on a denaturing gradient gel electrophoresis analysis of the 16S rRNA gene revealed that the communities were related. Specifically, the main bacterial members were identical to each other. The bacterial community was found to be dominated by Firmicutes, Actinobacteria, and Proteobacteria, which included Rhizobium, Pseudomonas, Lactococcus, Brevundimonas, Rheinheimera, Arthrobacter, Bacillus, and Herbaspirillum. Heterotrophic bacteria proliferation was observed during the period of stagnation, followed by a decrease of assimilable organic carbon and a slight increase of microbially available phosphorus. These findings indicated that the regrowth of bacteria might be boosted by the release of nutrients such as phosphorus from the pipe walls, as well as the decline of residual chlorine during stagnation. Inorganic contaminants at low levels, including Al, Mn, Zn, Pb, Cr, Cu, and Ni, were detected in tubercles and were concentrated in particulates from tap water following the release of iron during stagnation.

  9. Longitudinal and Source-to-Tap New Orleans, LA, U.S.A. Drinking Water Microbiology.

    PubMed

    Hull, Natalie M; Holinger, Eric P; Ross, Kimberly A; Robertson, Charles E; Harris, J Kirk; Stevens, Mark J; Pace, Norman R

    2017-04-18

    The two municipal drinking water systems of New Orleans, LA, U.S.A. were sampled to compare the microbiology of independent systems that treat the same surface water from the Mississippi River. To better understand temporal trends and sources of microbiology delivered to taps, these treatment plants and distribution systems were subjected to source-to-tap sampling over four years. Both plants employ traditional treatment by chloramination, applied during or after settling, followed by filtration before distribution in a warm, low water age system. Longitudinal samples indicated microbiology to have stability both spatially and temporally, and between treatment plants and distribution systems. Disinfection had the greatest impact on microbial composition, which was further refined by filtration and influenced by distribution and premise plumbing. Actinobacteria spp. exhibited trends with treatment. In particular, Mycobacterium spp., very low in finished waters, occurred idiosyncratically at high levels in some tap waters, indicating distribution and/or premise plumbing as main contributors of mycobacteria. Legionella spp., another genus containing potential opportunistic pathogens, also occurred ubiquitously. Source water microbiology was most divergent from tap water, and each step of treatment brought samples more closely similar to tap waters.

  10. Sticky trap and stem-tap sampling protocols for the Asian citrus psyllid (Hemiptera: Psyllidae)

    USDA-ARS?s Scientific Manuscript database

    Sampling statistics were obtained to develop a sampling protocol for estimating numbers of adult Diaphorina citri in citrus using two different sampling methods: yellow sticky traps and stem–tap samples. A 4.0 ha block of mature orange trees was stratified into ten 0.4 ha strata and sampled using...

  11. Isolation of Acanthamoeba Spp. from Drinking Waters in Several Hospitals of Iran

    PubMed Central

    Bagheri, HR; Shafiei, R; Shafiei, F; Sajjadi, SA

    2010-01-01

    Background Acanthamoeba is an opportunistic amphizoic protozoan found in different water sources including swimming pool as well as in sewage. The aim of this study was to investigate the prevalence of Acanthamoeba in tap-water samples in Iran. Method In this descriptive cross-sectional study, 94 samples of cold and warm tap-water were collected from different wards of hospitals in 13 cities of Iran in 2007–2008. Free residual chlorine, pH, and temperature of samples were measured. After filtration through multipore nylon membrane, samples were cultured on non-nutrient agar. Then we investigated existence of Acanthamoeba by reverse contrast phase microscope. Results Acanthamoeba was found in 45 samples (48%). Thirty-four and 11 positive samples were collected from cold and warm tap water, respectively. The samples belonged to the category of 20–30°C temperature with 0–2 ppm free residual chlorine and pH 6–7.4 showed the most coincidence to the positive cases. The greatest proportion of positive samples was obtained from Mashhad hospitals, while all samples collected from Arak and Semnan hospitals were negative. Conclusion considering the results of this study and the pathogenic role of this protozoan on patients with immunodeficiency, as well as capability of this microorganism in carrying other pathogens such as Legionella, further studies are needed. What is more important, potable water in hospitals should follow the procedure of treatment and sanitation, in order to prevent the relevant nosocomial infections. PMID:22347240

  12. Computerized measures of finger tapping: reliability, malingering and traumatic brain injury.

    PubMed

    Hubel, Kerry A; Yund, E William; Herron, Timothy J; Woods, David L

    2013-01-01

    We analyzed computerized finger tapping metrics in four experiments. Experiment 1 showed tapping-rate differences associated with hand dominance, digits, sex, and fatigue that replicated those seen in a previous, large-scale community sample. Experiment 2 revealed test-retest correlations (r = .91) that exceeded those reported in previous tapping studies. Experiment 3 investigated subjects simulating symptoms of traumatic brain injury (TBI); 62% of malingering subjects produced abnormally slow tapping rates. A tapping-rate malingering index, based on rate-independent tapping patterns, provided confirmatory evidence of malingering in 48% of the subjects with abnormal tapping rates. Experiment 4 compared tapping in 24 patients with mild TBI (mTBI) and a matched control group; mTBI patients showed slowed tapping without evidence of malingering. Computerized finger tapping measures are reliable measures of motor speed, useful in detecting subjects performing with suboptimal effort, and are sensitive to motor abnormalities following mTBI.

  13. [Investigation on contamination of Giardia and Cryptosporidium in drinking water in Jiangsu Province].

    PubMed

    Bi-Xian, N I; Ming-Xue, S; Xiang-Zhen, X U; Xiao-Ting, W; Yang, D; Xiao-Lin, J

    2017-05-17

    Objective To know the contamination status of Giardia lamblia and Cryptosporidium in drinking water of Jiangsu Province, so as to provide the evidence for producing hygiene and safety drinking water. Methods A total of 28 water plants of 13 cities in Jiangsu Province were selected, and the source water (10 L), chlorinated water (100 L) and tap water (100 L) were collected separately in each site. The water samples were then treated by filtration, washing, centrifuging concentration, immune magnetic separation, and immunofluorescent assay, to detect the numbers of Giardia cysts and Cryptosporidium oocysts. Results Totally 84 samples from 13 cities were collected, including 28 source water, 28 chlorinated water and 28 tap water samples. Among the chlorinated water and tap water samples, no Giardia cysts and Cryptosporidium oocysts were found. However, Giardia cysts were detected in 3 (10.71%, 3/28) source water samples (Yancheng, Lianyungang, Changzhou cities), with the density of 1 cyst/10 L of all. Cryptosporidium oocysts were also detected in 3 (10.71%, 3/28) source water samples (Nanjing, Zhenjiang, Yangzhou cities), with the density of 1 oocyst/10 L of all. Conclusions The source water in partial areas of Jiangsu Province has been contaminated by Giardia and Cryptosporidium . To ensure the safety of drinking, the regulation of source water and surveillance of drinking water should be strengthened.

  14. Occurrence of seven artificial sweeteners in the aquatic environment and precipitation of Tianjin, China.

    PubMed

    Gan, Zhiwei; Sun, Hongwen; Feng, Biting; Wang, Ruonan; Zhang, Yanwei

    2013-09-15

    Seventy water samples, including wastewaters, tap waters, fresh surface waters, coastal waters, groundwaters, and precipitation samples, from Tianjin, China, were analyzed for seven commonly used artificial sweeteners (ASs). The concentrations of the investigated ASs were generally in the order of wastewater treatment plant (WWTP) influent > WWTP effluent > surface water > tap water > groundwater ≈ precipitation, while the composition profiles of ASs varied in different waters. Acesulfame, sucralose, cyclamate, and saccharin were consistently detected in surface waters and ranged from 50 ng/L to 0.12 mg/L, while acesulfame was the dominant AS in surface and tap waters. Aspartame was found in all of the surface waters at a concentration up to 0.21 μg/L, but was not found in groundwaters and tap waters. Neotame and neohesperidin dihydrochalcone were less frequently detected and the concentrations were low. The concentrations of the ASs in some of the surface waters were of the same order with those in the WWTP influents, but not with the effluents, indicating there are probably untreated discharges into the surface waters. The ASs were detected in precipitation samples with high frequency, and acesulfame, saccharin, and cyclamate were the predominant ASs, with concentrations ranging from 3.5 ng/L to 1.3 μg/L. A gross estimation revealed that precipitation may act as a source for saccharin and cyclamate in the surface environment of Tianjin city. Moreover, the presence of ASs in the atmosphere was primarily assessed by taking 4 air samples to evaluate their potential source in precipitation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Spanish translation and validation of the Preschool Activity Card Sort.

    PubMed

    Stoffel, Ashley; Berg, Christine

    2008-05-01

    Few standardized assessments exist for children living in the United States who are Hispanic/Latino. This study reports the Spanish translation process for the Preschool Activity Card Sort (PACS), which is a measure of participation in preschool children, and examines content, construct, and concurrent validity. Methods of verifying accuracy of translation included expert review and back translation and supported content validity of the Tarjetas de Actividades Preescolares (TAP). Subsequently, a sample of 37 parents of children between 3 and 6 years of age completed the PACS/TAP by structured interview. Twenty-six parents were Spanish speaking, and 11 were English speaking. A comparison of reported participation by Spanish- and English-speaking children provides initial construct validity of the TAP. Results indicate that the TAP differentiates among children of recent immigrants as compared to preschoolers who were born in the United States on domains of self-care, high and low demand leisure, and educational activities. Results emphasize the importance of considering sociocultural influences when assessing participation. PACS/TAP scores were moderately correlated with Pediatric Evaluation of Disability Inventory scores for the self-care domain, but did not correlate with the mobility or social function domains. The PACS/TAP appears to provide a useful means of understanding preschoolers' participation. Future research is needed to further establish the validity of this assessment.

  16. Influence of storage conditions on aluminum concentrations in serum, dialysis fluid, urine, and tap water.

    PubMed

    Wilhelm, M; Ohnesorge, F K

    1990-01-01

    The influence of storage temperature, vessel type, and treatment on alterations of aluminum (Al) concentrations in serum, urine, and dialysis fluid samples was studied at three different concentrations for each sample over an 18-month period. Furthermore, the influence of acidification on Al levels in tap water, urine, and dialysis fluid samples was studied over a four-month period. Al was measured by atomic absorption spectrometry. Sample storage in glass vessels was unsuitable, whereas only minor alterations of Al levels were observed with storage in polypropylene tubes, polystyrene tubes, and Monovettes. By using appropriate plastic containers, acid washing of the vessels showed no improvement. Frozen storage was superior compared with 4 degrees C, whereas storage at -80 degrees C offered no advantage compared with storage at -20 degrees C. Acidification of tap water samples was necessary to stabilize Al levels during storage. No striking effect of acidification on Al levels in urine and dialysis fluid samples was found. It is concluded that longterm storage of serum, urine, tap water, and dialysis fluid samples is possible if appropriate conditions are used.

  17. Influence of tap water quality and household water use activities on indoor air and internal dose levels of trihalomethanes.

    PubMed

    Nuckols, John R; Ashley, David L; Lyu, Christopher; Gordon, Sydney M; Hinckley, Alison F; Singer, Philip

    2005-07-01

    Individual exposure to trihalomethanes (THMs) in tap water can occur through ingestion, inhalation, or dermal exposure. Studies indicate that activities associated with inhaled or dermal exposure routes result in a greater increase in blood THM concentration than does ingestion. We measured blood and exhaled air concentrations of THM as biomarkers of exposure to participants conducting 14 common household water use activities, including ingestion of hot and cold tap water beverages, showering, clothes washing, hand washing, bathing, dish washing, and indirect shower exposure. We conducted our study at a single residence in each of two water utility service areas, one with relatively high and the other low total THM in the residence tap water. To maintain a consistent exposure environment for seven participants, we controlled water use activities, exposure time, air exchange, water flow and temperature, and nonstudy THM sources to the indoor air. We collected reference samples for water supply and air (pre-water use activity), as well as tap water and ambient air samples. We collected blood samples before and after each activity and exhaled breath samples at baseline and post-activity. All hot water use activities yielded a 2-fold increase in blood or breath THM concentrations for at least one individual. The greatest observed increase in blood and exhaled breath THM concentration in any participant was due to showering (direct and indirect), bathing, and hand dishwashing. Average increase in blood THM concentration ranged from 57 to 358 pg/mL due to these activities. More research is needed to determine whether acute and frequent exposures to THM at these concentrations have public health implications. Further research is also needed in designing epidemiologic studies that minimize data collection burden yet maximize accuracy in classification of dermal and inhalation THM exposure during hot water use activities.

  18. Influence of Tap Water Quality and Household Water Use Activities on Indoor Air and Internal Dose Levels of Trihalomethanes

    PubMed Central

    Nuckols, John R.; Ashley, David L.; Lyu, Christopher; Gordon, Sydney M.; Hinckley, Alison F.; Singer, Philip

    2005-01-01

    Individual exposure to trihalomethanes (THMs) in tap water can occur through ingestion, inhalation, or dermal exposure. Studies indicate that activities associated with inhaled or dermal exposure routes result in a greater increase in blood THM concentration than does ingestion. We measured blood and exhaled air concentrations of THM as biomarkers of exposure to participants conducting 14 common household water use activities, including ingestion of hot and cold tap water beverages, showering, clothes washing, hand washing, bathing, dish washing, and indirect shower exposure. We conducted our study at a single residence in each of two water utility service areas, one with relatively high and the other low total THM in the residence tap water. To maintain a consistent exposure environment for seven participants, we controlled water use activities, exposure time, air exchange, water flow and temperature, and nonstudy THM sources to the indoor air. We collected reference samples for water supply and air (pre–water use activity), as well as tap water and ambient air samples. We collected blood samples before and after each activity and exhaled breath samples at baseline and postactivity. All hot water use activities yielded a 2-fold increase in blood or breath THM concentrations for at least one individual. The greatest observed increase in blood and exhaled breath THM concentration in any participant was due to showering (direct and indirect), bathing, and hand dishwashing. Average increase in blood THM concentration ranged from 57 to 358 pg/mL due to these activities. More research is needed to determine whether acute and frequent exposures to THM at these concentrations have public health implications. Further research is also needed in designing epidemiologic studies that minimize data collection burden yet maximize accuracy in classification of dermal and inhalation THM exposure during hot water use activities. PMID:16002374

  19. Computerized measures of finger tapping: effects of hand dominance, age, and sex.

    PubMed

    Hubel, Kerry A; Reed, Bruce; Yund, E William; Herron, Timothy J; Woods, David L

    2013-06-01

    Computerized measures of digit tapping rate were obtained over 3 successive, 10-sec. periods in the right and left index fingers, from a community sample of 1,519 participants (ages 18 to 65 years; 607 men, 912 women). Differences between the dominant and non-dominant hands were found for tapping rate, movement initiation, and button down times, and the decline in tapping rate over the successive, 10-sec. periods. Declines were found in tapping rate in older participants in association with increased intertap variability. Men had higher tapping rates than women in all age ranges. The computerized finger tapping test is an efficient and precise measure of tapping speed and kinetics of potential utility in research and clinical studies of motor performance.

  20. Comparsion of an immunochromatographic strip with ELISA for simultaneous detection of thiamphenicol, florfenicol and chloramphenicol in food samples.

    PubMed

    Guo, Lingling; Song, Shanshan; Liu, Liqiang; Peng, Juan; Kuang, Hua; Xu, Chuanlai

    2015-09-01

    Rapid and sensitive indirect competitive enzyme-linked immunosorbent assays (ic-ELISA) and gold nanoparticle immunochromatographic strip tests were developed to detect thiamphenicol (TAP), florfenicol (FF) and chloramphenicol (CAP) in milk and honey samples. The generic monoclonal antibody for TAP, FF and CAP was prepared based on a hapten [D-threo-1-(4-aminophenyl)-2- dichloroacetylamino-1,3-propanediol], and the haptenwas linked to a carrier protein using the diazotization method. After the optimization of several parameters (coating, pH, sodium chloride content and methanol content), the ic-ELISA was established. The quantitative working range for TAP was 0.11-1.36 ng/mL, with an IC50 of 0.39 ng/mL. The optimized ELISA showed cross-reactivity to CAP (300%) and FF (15.6%), with IC50 values of 0.13 and 2.5 ng/mL, respectively. The analytical recovery of TAP, FF and CAP in milk and honey samples in the ic-ELISA ranged from 81.2 to 112.9%. Based on this monoclonal antibody, a rapid and sensitive immunochromatographic test strip was also developed. This strip had a detection limit of 1 ng/mL for TAP, FF and CAP in milk and honey samples. Moreover, the test was completed within 10 min. Our results showed that the proposed ic-ELISA and immunochromatographic test strip method are highly useful screening tools for TAP, FF and CAP detection in milk and honey samples. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Occurrence of immunosuppressive drugs and their metabolites in the sewage-impacted Vistula and Utrata Rivers and in tap water from the Warsaw region (Poland).

    PubMed

    Giebułtowicz, Joanna; Nałęcz-Jawecki, Grzegorz

    2016-04-01

    Immunosuppresive therapy following organ transplant frequently includes treatment with tacrolimus and mycophenolic acid derivatives. These pharmaceuticals may enter the environment through wastewater treatment plant (WWTP) effluents and may have a potentially harmful effect on aquatic biota. Tacrolimus, mycophenolic acid and their metabolites were measured at specific points of a large Polish river (Vistula), a smaller river (Utrata) and in tap water samples from the Warsaw region. Analysis was performed using liquid chromatography tandem mass spectrometry, after solid phase extraction for water samples, or QuEChERS extraction for sediments. Residues of tacrolimus were below quantitation limits in both water and sediment samples. However, in water samples mycophenolic acid concentrations were measured at up to 180 ng L(-1) downstream of WWTP outfalls. No immunosuppressive drugs were detected in tap water. Concentrations of mycophenolic acid exceeded the predicted no effect concentration (PNEC) value in some Polish surface water, and risk calculations predicted at least twice higher concentrations in some other countries of the European Union. To the best of the authors' knowledge, this is the first report of these immunosuppressive drug concentrations in the environment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Stable isotope ratios of tap water in the contiguous United States

    NASA Astrophysics Data System (ADS)

    Bowen, Gabriel J.; Ehleringer, James R.; Chesson, Lesley A.; Stange, Erik; Cerling, Thure E.

    2007-03-01

    Understanding links between water consumers and climatological (precipitation) sources is essential for developing strategies to ensure the long-term sustainability of water supplies. In pursing this understanding a need exists for tools to study and monitor complex human-hydrological systems that involve high levels of spatial connectivity and supply problems that are regional, rather than local, in nature. Here we report the first national-level survey of stable isotope ratios in tap water, including spatially and temporally explicit samples from a large number of cities and towns across the contiguous United States. We show that intra-annual ranges of tap water isotope ratios are relatively small (e.g., <10‰ for δ2H) at most sites. In contrast, spatial variation in tap water isotope ratios is very large, spanning ranges of 163‰ for δ2H and 23.6‰ for δ18O. The spatial distribution of tap water isotope ratios at the national level is similar to that of stable isotope ratios of precipitation. At the regional level, however, pervasive differences between tap water and precipitation isotope ratios can be attributed to hydrological factors in the water source to consumer chain. These patterns highlight the potential for monitoring of tap water isotope ratios to contribute to the study of regional water supply stability and provide warning signals for impending water resource changes. We present the first published maps of predicted tap water isotope ratios for the contiguous United States, which will be useful in guiding future research on human-hydrological systems and as a tool for applied forensics and traceability studies.

  3. Fast, High Resolution, and Wide Modulus Range Nanomechanical Mapping with Bimodal Tapping Mode.

    PubMed

    Kocun, Marta; Labuda, Aleksander; Meinhold, Waiman; Revenko, Irène; Proksch, Roger

    2017-10-24

    Tapping mode atomic force microscopy (AFM), also known as amplitude modulated (AM) or AC mode, is a proven, reliable, and gentle imaging mode with widespread applications. Over the several decades that tapping mode has been in use, quantification of tip-sample mechanical properties such as stiffness has remained elusive. Bimodal tapping mode keeps the advantages of single-frequency tapping mode while extending the technique by driving and measuring an additional resonant mode of the cantilever. The simultaneously measured observables of this additional resonance provide the additional information necessary to extract quantitative nanomechanical information about the tip-sample mechanics. Specifically, driving the higher cantilever resonance in a frequency modulated (FM) mode allows direct measurement of the tip-sample interaction stiffness and, with appropriate modeling, the set point-independent local elastic modulus. Here we discuss the advantages of bimodal tapping, coined AM-FM imaging, for modulus mapping. Results are presented for samples over a wide modulus range, from a compliant gel (∼100 MPa) to stiff materials (∼100 GPa), with the same type of cantilever. We also show high-resolution (subnanometer) stiffness mapping of individual molecules in semicrystalline polymers and of DNA in fluid. Combined with the ability to remain quantitative even at line scan rates of nearly 40 Hz, the results demonstrate the versatility of AM-FM imaging for nanomechanical characterization in a wide range of applications.

  4. Lead and Copper Tap Sample Site Plan Instructions

    EPA Pesticide Factsheets

    This document may be used by public water systems in Wyoming and on EPA R8 Tribal Lands as a guide for how to properly complete their lead and copper tap sample site plans to comply with the Lead and Copper Rule.

  5. Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    PubMed Central

    2010-01-01

    Background Malaria rapid diagnostic tests (RDTs) are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution) or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands) showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74%) RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20), and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs). Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness) of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results. PMID:20650003

  6. Monitoring of Emerging and Legacy Contaminants in Groundwater and Tap Water of the Karst Region in Northern Puerto Rico for Assessment of Sources and Fate and Transport Processes

    NASA Astrophysics Data System (ADS)

    Padilla, I. Y.; Cotto, I.; Torres, P. M.

    2014-12-01

    The karst aquifer region of northern Puerto Rico is the area with the highest groundwater extraction in the island. Urban and industrial development has led to extensive contamination of the groundwater in the region. Of particular concern, is the presence of emerging and legacy organic contaminants, such as phthalates and chlorinated organic compounds (CVOCs), because there high risk for exposure and adverse health impact. Variable sources and the heterogeneous and dynamic conditions of karst groundwater systems, limits the ability to properly assess and manage the water quality of these precious water resources. This work develops a monitoring and water analysis scheme to assess spatial-temporal exposure of hazardous contaminants trough karst water in northern Puerto Rico. Groundwater and tap water are sampled in the region and analyzed for phthalates, CVOCs, and common ions. Detections and concentrations of phthalates and CVOCs are determined by using modified EPA methods, which rely on liquid-liquid extractions and gas chromatography techniques. The modified methods have reduced the volume of samples and solvent waste, decreased the time of analysis, increased analysis outcomes, and lower potential for hazardous exposure. Results show intermittent presence of di-ethyl, di-butyl and di (2-ethyl hexyl) phthalates in 36% of the groundwater and 53% of tap water samples, with detected concentrations ranging between 0.1-88.7 μg/L. These results indicate that karst groundwater can serve as a route of exposure for phthalates, but there are additional disperse sources in the water system. CVOCs are detected in groundwater at much higher frequencies (50%) than phthalates, and include trichloromethane (TCM), carbon tetrachloride (CT), trichloroethylene (TCE), and tetrachloroethylene (TCE). CVOCs, except for TCM, are found at lower frequencies on tap water (5.8%) than groundwater (27%). TCM is detected more frequently and at higher concentrations in tap water (56.8%) than tap water (30%). Results indicated that most CVOCs on tap water come from groundwater sources. Spatial-temporal analysis of CVOC data shows that transport through karst system is highly heterogeneous variable, and reflect high capacity of the system to store and slowly release contaminants through rate-limited mass transport process.

  7. A large community outbreak of gastroenteritis associated with consumption of drinking water contaminated by river water, Belgium, 2010.

    PubMed

    Braeye, T; DE Schrijver, K; Wollants, E; van Ranst, M; Verhaegen, J

    2015-03-01

    SUMMARY On 6 December 2010 a fire in Hemiksem, Belgium, was extinguished by the fire brigade with both river water and tap water. Local physicians were asked to report all cases of gastroenteritis. We conducted a retrospective cohort study among 1000 randomly selected households. We performed a statistical and geospatial analysis. Human stool samples, tap water and river water were tested for pathogens. Of the 1185 persons living in the 528 responding households, 222 (18·7%) reported symptoms of gastroenteritis during the time period 6-13 December. Drinking tap water was significantly associated with an increased risk for gastroenteritis (relative risk 3·67, 95% confidence interval 2·86-4·70) as was place of residence. Campylobacter sp. (2/56), norovirus GI and GII (11/56), rotavirus (1/56) and Giardia lamblia (3/56) were detected in stool samples. Tap water samples tested positive for faecal indicator bacteria and protozoa. The results support the hypothesis that a point-source contamination of the tap water with river water was the cause of the multi-pathogen waterborne outbreak.

  8. Major inorganic elements in tap water samples in Peninsular Malaysia.

    PubMed

    Azrina, A; Khoo, H E; Idris, M A; Amin, I; Razman, M R

    2011-08-01

    Quality drinking water should be free from harmful levels of impurities such as heavy metals and other inorganic elements. Samples of tap water collected from 24 locations in Peninsular Malaysia were determined for inorganic element content. Minerals and heavy metals were analysed by spectroscopy methods, while non-metal elements were analysed using test kits. Minerals and heavy metals determined were sodium, magnesium, potassium, calcium, chromium, manganese, iron, nickel, copper, zinc, arsenic, cadmium and lead while the non-metal elements were fluoride, chloride, nitrate and sulphate. Most of the inorganic elements found in the samples were below the maximum permitted levels recommended by inter-national drinking water standard limits, except for iron and manganese. Iron concentration of tap water from one of the locations was higher than the standard limit. In general, tap water from different parts of Peninsular Malaysia had low concentrations of heavy metals and inorganic elements.

  9. Disparity in disinfection byproducts concentration between hot and cold tap water.

    PubMed

    Liu, Boning; Reckhow, David A

    2015-03-01

    The quality of water entering a distribution system may differ substantially from the quality at the point of exposure to the consumer. This study investigated temporal variations in the levels of regulated and non-regulated disinfection byproducts (DBPs) in cold and hot tap water in a home on a medium-sized municipal water system. In addition, samples were collected directly from the water plant with some being held in accordance with a simulated distribution system (SDS) test protocol. The location for this work was a system in western Massachusetts, USA that uses free chlorine as a final disinfectant. Very little short term variability of DBPs at the point of entry (POE) was observed. The concentration of DBPs in the time-variable SDS test was similar to concentrations in the cold water tap. For most DBPs, the concentrations continued to increase as the cold water tap sample was held for the time-variable SDS incubation period. However, the impact of heating on DBP levels was compound specific. For example, the concentrations of trihalomethanes (THMs), dichloroacetic acid (DCAA) and chloropicrin (CP) were substantially higher in the hot water tap than in the cold water time-variable SDS samples. In contrast, the concentration of trichloroacetic acid (TCAA) was lower in the heated hot tap water, but about equal to that observed in the cold tap water. The situation was more pronounced for dichloroacetonitrile (DCAN), bromodichloroacetic acid (BDCAA), bromochloroacetic acid (BCAA) and 1,1,1-trichloropropanone (TCP), which all showed lower concentrations in the hot water then in either of the cold water samples (instantaneous or time-variable SDS). The latter was viewed as a clear indication of thermally-induced decomposition. The ratio of unknown total organic halide (UTOX) to TOX was substantially lower in the hot tap water as the THM to TOX ratio became correspondingly larger. The results of this study show that DBP exposure in the home is not well represented by concentrations measured in cold water taps where most compliance monitoring is done. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Method of joint bit rate/modulation format identification and optical performance monitoring using asynchronous delay-tap sampling for radio-over-fiber systems

    NASA Astrophysics Data System (ADS)

    Guesmi, Latifa; Menif, Mourad

    2016-08-01

    In the context of carrying a wide variety of modulation formats and data rates for home networks, the study covers the radio-over-fiber (RoF) technology, where the need for an alternative way of management, automated fault diagnosis, and formats identification is expressed. Also, RoF signals in an optical link are impaired by various linear and nonlinear effects including chromatic dispersion, polarization mode dispersion, amplified spontaneous emission noise, and so on. Hence, for this purpose, we investigated the sampling method based on asynchronous delay-tap sampling in conjunction with a cross-correlation function for the joint bit rate/modulation format identification and optical performance monitoring. Three modulation formats with different data rates are used to demonstrate the validity of this technique, where the identification accuracy and the monitoring ranges reached high values.

  11. Sensitivity, specificity and predictive values of anterior chamber tap in cases of bacterial endophthalmitis.

    PubMed

    Sjoholm-Gomez de Liano, Carl; Soberon-Ventura, Vidal F; Salcedo-Villanueva, Guillermo; Santos-Palacios, Abril; Guerrero-Naranjo, Jose Luis; Fromow-Guerra, Jans; García-Aguirre, Gerardo; Morales-Canton, Virgilio; Velez-Montoya, Raul

    2017-01-01

    To assess the sensitivity, specificity, positive predictive value and negative predictive value of anterior chamber tap for the diagnosis of bacterial endophthalmitis on a population with high prevalence. Retrospective, single centre, case series study. We reviewed all medical records with clinical diagnosis of bacterial endophthalmitis in our hospital from January 1st, 2000 to December 31st 2014. From each record, we documented general demographic data, best corrected visual acuity and vitreous and aqueous tap microbiological results. All cases were further divided according to the endophthalmitis aetiology to perform individual calculations of sensitivity, specificity, positive predictive value, negative predictive value, accuracy and prevalence. We used the results of the vitreous tap as the gold standard for diagnosis of bacterial endophthalmitis. We excluded those records in which the aqueous and vitreous samples were not taken simultaneously or had an incomplete microbiological report. Significance were assessed with chi squared statistics, with an alpha value of 0.05 for statistical significance. A total of 190 cases fulfilled the inclusion/exclusion criteria. Positive culture rate from vitreous samples was 64.74%. Positive culture rate from aqueous sample was 32.11%. Bacteria isolated from aqueous samples matched those isolated from vitreous samples 78.68% of the time. The overall sensitivity was 38.21%, specificity: 75.51%, positive predictive value: 79.66%, negative predictive value: 32.74% ( p  = 0.08). Subgroup analysis showed that anterior chamber taps in cases of post-surgical endophthalmitis had a moderate to low sensitivity (37.73%), high specificity (93%) and high positive predictive value (95%) ( p  < 0.04). The sensitivity and specificity of anterior chamber tap are low and should not be used for critical therapeutic decisions in patients with suspected bacterial endophthalmitis. In cases of post-surgical endophthalmitis, the result of an anterior chamber tap could be used for therapeutic guidance, but only in conjunction with clinical presentation and in the absence of a better method for diagnosis.

  12. Lumber value loss associated with tapping sugar maples for sap production

    Treesearch

    Paul E. Sendak; Neil K. Huyler; Lawrence D. Garrett

    1982-01-01

    Tapping sugar maples for sap production yields an annual income, but there is a loss in timber quality if the tree is cut for factory lumber products. We estimate an average loss per tree of $2.87 based on a sample of 90 trees in Vermont that were formerly tapped.

  13. An Environmental Friendly Procedure for Photometric Determination of Hypochlorite in Tap Water Employing a Miniaturized Multicommuted Flow Analysis Setup

    PubMed Central

    Borges, Sivanildo S.; Reis, Boaventura F.

    2011-01-01

    A photometric procedure for the determination of ClO− in tap water employing a miniaturized multicommuted flow analysis setup and an LED-based photometer is described. The analytical procedure was implemented using leucocrystal violet (LCV; 4,4′,4′′-methylidynetris (N,N-dimethylaniline), C25H31N3) as a chromogenic reagent. Solenoid micropumps employed for solutions propelling were assembled together with the photometer in order to compose a compact unit of small dimensions. After control variables optimization, the system was applied for the determination of ClO− in samples of tap water, and aiming accuracy assessment samples were also analyzed using an independent method. Applying the paired t-test between results obtained using both methods, no significant difference at the 95% confidence level was observed. Other useful features include low reagent consumption, 2.4 μg of LCV per determination, a linear response ranging from 0.02 up to 2.0 mg L−1  ClO−, a relative standard deviation of 1.0% (n = 11) for samples containing 0.2 mg L−1  ClO−, a detection limit of 6.0 μg L−1  ClO−, a sampling throughput of 84 determinations per hour, and a waste generation of 432 μL per determination. PMID:21747732

  14. NHEXAS PHASE I MARYLAND STUDY--PESTICIDES IN WATER ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticides in Water data set contains analytical results for measurements of up to 10 pesticides in 388 water samples over 80 households. One-liter samples of tap water were collected after a two-minute flush from the tap identified by the resident as that most commonly used...

  15. A highly selective electrochemical sensor based on molecularly imprinted polypyrrole-modified gold electrode for the determination of glyphosate in cucumber and tap water.

    PubMed

    Zhang, Chao; She, Yongxin; Li, Tengfei; Zhao, Fengnian; Jin, Maojun; Guo, Yirong; Zheng, Lufei; Wang, Shanshan; Jin, Fen; Shao, Hua; Liu, Haijin; Wang, Jing

    2017-12-01

    An electrochemical sensor based on molecularly imprinted polypyrrole (MIPPy) was developed for selective and sensitive detection of the herbicide glyphosate (Gly) in cucumber and tap water samples. The sensor was prepared via synthesis of molecularly imprinted polymers on a gold electrode in the presence of Gly as the template molecule and pyrrole as the functional monomer by cyclic voltammetry (CV). The sensor preparation conditions including the ratio of template to functional monomers, number of CV cycles in the electropolymerization process, the method of template removal, incubation time, and pH were optimized. Under the optimal experimental conditions, the DPV peak currents of hexacyanoferrate/hexacyanoferrite changed linearly with Gly concentration in the range from 5 to 800 ng mL -1 , with a detection limit of 0.27 ng mL -1 (S/N = 3). The sensor was used to detect the concentration of Gly in cucumber and tap water samples, with recoveries ranging from 72.70 to 98.96%. The proposed sensor showed excellent selectivity, good stability and reversibility, and could detect the Gly in real samples rapidly and sensitively. Graphical abstract Schematic illustration of the experimental procedure to detect Gly using the MIPPy electrode.

  16. A Waterborne Outbreak and Detection of Cryptosporidium Oocysts in Drinking Water of an Older High-Rise Apartment Complex in Seoul

    PubMed Central

    Yang, Jin-Young; Lee, Eun-Sook; Kim, Se-Chul; Cha, So-Yang; Kim, Sung-Tek; Lee, Man-Ho; Han, Sun-Hee; Park, Young-Sang

    2013-01-01

    From May to June 2012, a waterborne outbreak of 124 cases of cryptosporidiosis occurred in the plumbing systems of an older high-rise apartment complex in Seoul, Republic of Korea. The residents of this apartment complex had symptoms of watery diarrhea and vomiting. Tap water samples in the apartment complex and its adjacent buildings were collected and tested for 57 parameters under the Korean Drinking Water Standards and for additional 11 microbiological parameters. The microbiological parameters included total colony counts, Clostridium perfringens, Enterococcus, fecal streptococcus, Salmonella, Shigella, Pseudomonas aeruginosa, Cryptosporidium oocysts, Giardia cysts, total culturable viruses, and Norovirus. While the tap water samples of the adjacent buildings complied with the Korean Drinking Water Standards for all parameters, fecal bacteria and Cryptosporidium oocysts were detected in the tap water samples of the outbreak apartment complex. It turned out that the agent of the disease was Cryptosporidium parvum. The drinking water was polluted with sewage from a septic tank in the apartment complex. To remove C. parvum oocysts, we conducted physical processes of cleaning the water storage tanks, flushing the indoor pipes, and replacing old pipes with new ones. Finally we restored the clean drinking water to the apartment complex after identification of no oocysts. PMID:24039290

  17. A waterborne outbreak and detection of cryptosporidium oocysts in drinking water of an older high-rise apartment complex in seoul.

    PubMed

    Cho, Eun-Joo; Yang, Jin-Young; Lee, Eun-Sook; Kim, Se-Chul; Cha, So-Yang; Kim, Sung-Tek; Lee, Man-Ho; Han, Sun-Hee; Park, Young-Sang

    2013-08-01

    From May to June 2012, a waterborne outbreak of 124 cases of cryptosporidiosis occurred in the plumbing systems of an older high-rise apartment complex in Seoul, Republic of Korea. The residents of this apartment complex had symptoms of watery diarrhea and vomiting. Tap water samples in the apartment complex and its adjacent buildings were collected and tested for 57 parameters under the Korean Drinking Water Standards and for additional 11 microbiological parameters. The microbiological parameters included total colony counts, Clostridium perfringens, Enterococcus, fecal streptococcus, Salmonella, Shigella, Pseudomonas aeruginosa, Cryptosporidium oocysts, Giardia cysts, total culturable viruses, and Norovirus. While the tap water samples of the adjacent buildings complied with the Korean Drinking Water Standards for all parameters, fecal bacteria and Cryptosporidium oocysts were detected in the tap water samples of the outbreak apartment complex. It turned out that the agent of the disease was Cryptosporidium parvum. The drinking water was polluted with sewage from a septic tank in the apartment complex. To remove C. parvum oocysts, we conducted physical processes of cleaning the water storage tanks, flushing the indoor pipes, and replacing old pipes with new ones. Finally we restored the clean drinking water to the apartment complex after identification of no oocysts.

  18. Fecal indicators and zoonotic pathogens in household drinking water taps fed from rainwater tanks in Southeast Queensland, Australia.

    PubMed

    Ahmed, W; Hodgers, L; Sidhu, J P S; Toze, S

    2012-01-01

    In this study, the microbiological quality of household tap water samples fed from rainwater tanks was assessed by monitoring the numbers of Escherichia coli bacteria and enterococci from 24 households in Southeast Queensland (SEQ), Australia. Quantitative PCR (qPCR) was also used for the quantitative detection of zoonotic pathogens in water samples from rainwater tanks and connected household taps. The numbers of zoonotic pathogens were also estimated in fecal samples from possums and various species of birds by using qPCR, as possums and birds are considered to be the potential sources of fecal contamination in roof-harvested rainwater (RHRW). Among the 24 households, 63% of rainwater tank and 58% of connected household tap water (CHTW) samples contained E. coli and exceeded Australian drinking water guidelines of <1 CFU E. coli per 100 ml water. Similarly, 92% of rainwater tanks and 83% of CHTW samples also contained enterococci. In all, 21%, 4%, and 13% of rainwater tank samples contained Campylobacter spp., Salmonella spp., and Giardia lamblia, respectively. Similarly, 21% of rainwater tank and 13% of CHTW samples contained Campylobacter spp. and G. lamblia, respectively. The number of E. coli (P = 0.78), Enterococcus (P = 0.64), Campylobacter (P = 0.44), and G. lamblia (P = 0.50) cells in rainwater tanks did not differ significantly from the numbers observed in the CHTW samples. Among the 40 possum fecal samples tested, Campylobacter spp., Cryptosporidium parvum, and G. lamblia were detected in 60%, 13%, and 30% of samples, respectively. Among the 38 bird fecal samples tested, Campylobacter spp., Salmonella spp., C. parvum, and G. lamblia were detected in 24%, 11%, 5%, and 13% of the samples, respectively. Household tap water samples fed from rainwater tanks tested in the study appeared to be highly variable. Regular cleaning of roofs and gutters, along with pruning of overhanging tree branches, might also prove effective in reducing animal fecal contamination of rainwater tanks.

  19. Fecal Indicators and Zoonotic Pathogens in Household Drinking Water Taps Fed from Rainwater Tanks in Southeast Queensland, Australia

    PubMed Central

    Hodgers, L.; Sidhu, J. P. S.; Toze, S.

    2012-01-01

    In this study, the microbiological quality of household tap water samples fed from rainwater tanks was assessed by monitoring the numbers of Escherichia coli bacteria and enterococci from 24 households in Southeast Queensland (SEQ), Australia. Quantitative PCR (qPCR) was also used for the quantitative detection of zoonotic pathogens in water samples from rainwater tanks and connected household taps. The numbers of zoonotic pathogens were also estimated in fecal samples from possums and various species of birds by using qPCR, as possums and birds are considered to be the potential sources of fecal contamination in roof-harvested rainwater (RHRW). Among the 24 households, 63% of rainwater tank and 58% of connected household tap water (CHTW) samples contained E. coli and exceeded Australian drinking water guidelines of <1 CFU E. coli per 100 ml water. Similarly, 92% of rainwater tanks and 83% of CHTW samples also contained enterococci. In all, 21%, 4%, and 13% of rainwater tank samples contained Campylobacter spp., Salmonella spp., and Giardia lamblia, respectively. Similarly, 21% of rainwater tank and 13% of CHTW samples contained Campylobacter spp. and G. lamblia, respectively. The number of E. coli (P = 0.78), Enterococcus (P = 0.64), Campylobacter (P = 0.44), and G. lamblia (P = 0.50) cells in rainwater tanks did not differ significantly from the numbers observed in the CHTW samples. Among the 40 possum fecal samples tested, Campylobacter spp., Cryptosporidium parvum, and G. lamblia were detected in 60%, 13%, and 30% of samples, respectively. Among the 38 bird fecal samples tested, Campylobacter spp., Salmonella spp., C. parvum, and G. lamblia were detected in 24%, 11%, 5%, and 13% of the samples, respectively. Household tap water samples fed from rainwater tanks tested in the study appeared to be highly variable. Regular cleaning of roofs and gutters, along with pruning of overhanging tree branches, might also prove effective in reducing animal fecal contamination of rainwater tanks. PMID:22020514

  20. Evaluation of transversus abdominis plane block for renal transplant recipients - A meta-analysis and trial sequential analysis of published studies.

    PubMed

    Singh, Preet Mohinder; Borle, Anuradha; Makkar, Jeetinder Kaur; Trisha, Aanjan; Sinha, Aashish

    2018-01-01

    Patients undergoing renal transplant (RT) have altered drug/opioid pharmacokinetics. Transversus abdominis plane (TAP) block in renal transplant recipients has been recently evaluated for analgesic and opioid-sparing potential by many trials. The studies comparing TAP-block to conventional analgesic regimens for RT were searched. Comparisons were made for total opioids consumed (as morphine-equivalents) during the first postoperative 24-h (primary objective), intraoperative, and immediate-postoperative period. Pain scores and postoperative nausea-vomiting (PONV) were also evaluated. Trial sequential analysis (TSA) was used to quantify the strength of analysis. Ten-trials with 258 and 237 patients in control and TAP-block group, respectively, were included. TAP-block decreased the 24-h (reported in 9-trials) opioid consumption by 14.61 ± 4.34 mg (reduction by 42.7%, random-effects, P < 0.001, I 2 = 97.82%). Sample size of the present analysis (472) was well past the required "information-size" variable (396) as per the TSA for a power of 85%. Intraoperative opioid consumption also decreased by 2.06 ± 0.63 mg (reduction of 27.8%) (random effects, P < 0.001, I 2 = 98.84%). Pain scores with TAP-block were significantly lower in both early and delayed postoperative phase. Odds ratio for PONV without TAP block was 1.99 ± 1.05 (Fixed-effects, P = 0.04, I 2 = 0%). Publication bias was likely (Egger's test, X-intercept=7.89, P < 0.05). TAP-block significantly lowers the intraoperative and cumulative postoperative 24-h opioid consumption in RT recipients. Persistent and better pain control is achieved when TAP-Block is used. Benefits of TAP block extend beyond the analgesic actions alone as it also decreases the 24-h incidence of postoperative nausea vomiting as well. The technique of the block needs standardization for RT recipients.

  1. Immunoaffinity column as clean-up tool for determination of trace amounts of microcystins in tap water.

    PubMed

    Tsutsumi, T; Nagata, S; Hasegawa, A; Ueno, Y

    2000-07-01

    Trace amounts of microcystins (MCs) in drinking water should be monitored because of their potential hazard for human health as an environmental tumor promoter. We describe here a new clean-up tool with immunoaffinity column (IAC) for determination of trace amounts of MCs (from pg to microg/litre) in tap water. The water samples were concentrated with IAC clean-up and MCs levels were determined by HPLC with UV detection or enzyme-linked immunosorbent assay (ELISA). In the combination with HPLC analysis, mean recovery of microcystin-LR (MCLR),-RR and-YR spiked to tap water were 91.8%, 77.3% and 86.4%, respectively, in the range 2.5-100 microg/litre. The chromatogram of MCs-spiked tap water sample cleaned up with IAC showed effective elimination of the impurities compared to that with octadecyl silanized cartridge, which had been cleaned up with a conventional method. Also, in the combination with highly sensitive ELISA, mean recovery of MCLR spiked to tap water was 80% in the range 0.1-1000 ng/litre. The combined methods developed here can detect pg to microg/litre of MCs in tap water. The overall results indicated that IAC will be suitable as a clean-up tool for trace amounts of MCs in tap water.

  2. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE AND SHIPMENT OF DRINKING AND TAP WATER SAMPLES FOR VOCS (EPA METHOD 524.2) (UA-F-18.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the collection, storage, and shipment of tap and drinking water samples for analysis by EPA method 524.2 (revision 4.0) for the NHEXAS Arizona project. This SOP provides a brief description of the sample containers, collection, preservation...

  3. 40 CFR 141.88 - Monitoring requirements for lead and copper in source water.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the basis of tap samples collected in accordance with § 141.86 shall collect lead and copper source... value or be considered one-half the PQL. (b) Monitoring frequency after system exceeds tap water action level. Any system which exceeds the lead or copper action level at the tap shall collect one source...

  4. Analysis of dynamic cantilever behavior in tapping mode atomic force microscopy.

    PubMed

    Deng, Wenqi; Zhang, Guang-Ming; Murphy, Mark F; Lilley, Francis; Harvey, David M; Burton, David R

    2015-10-01

    Tapping mode atomic force microscopy (AFM) provides phase images in addition to height and amplitude images. Although the behavior of tapping mode AFM has been investigated using mathematical modeling, comprehensive understanding of the behavior of tapping mode AFM still poses a significant challenge to the AFM community, involving issues such as the correct interpretation of the phase images. In this paper, the cantilever's dynamic behavior in tapping mode AFM is studied through a three dimensional finite element method. The cantilever's dynamic displacement responses are firstly obtained via simulation under different tip-sample separations, and for different tip-sample interaction forces, such as elastic force, adhesion force, viscosity force, and the van der Waals force, which correspond to the cantilever's action upon various different representative computer-generated test samples. Simulated results show that the dynamic cantilever displacement response can be divided into three zones: a free vibration zone, a transition zone, and a contact vibration zone. Phase trajectory, phase shift, transition time, pseudo stable amplitude, and frequency changes are then analyzed from the dynamic displacement responses that are obtained. Finally, experiments are carried out on a real AFM system to support the findings of the simulations. © 2015 Wiley Periodicals, Inc.

  5. Widespread molecular detection of Legionella pneumophila Serogroup 1 in cold water taps across the United States.

    PubMed

    Donohue, Maura J; O'Connell, Katharine; Vesper, Stephen J; Mistry, Jatin H; King, Dawn; Kostich, Mitch; Pfaller, Stacy

    2014-03-18

    In the United States, 6,868 cases of legionellosis were reported to the Center for Disease Control and Prevention in 2009-2010. Of these reports, it is estimated that 84% are caused by the microorganism Legionella pneumophila Serogroup (Sg) 1. Legionella spp. have been isolated and recovered from a variety of natural freshwater environments. Human exposure to L. pneumophila Sg1 may occur from aerosolization and subsequent inhalation of household and facility water. In this study, two primer/probe sets (one able to detect L. pneumophila and the other L. pneumophila Sg1) were determined to be highly sensitive and selective for their respective targets. Over 272 water samples, collected in 2009 and 2010 from 68 public and private water taps across the United States, were analyzed using the two qPCR assays to evaluate the incidence of L. pneumophila Sg1. Nearly half of the taps showed the presence of L. pneumophila Sg1 in one sampling event, and 16% of taps were positive in more than one sampling event. This study is the first United States survey to document the occurrence and colonization of L. pneumophila Sg1 in cold water delivered from point of use taps.

  6. NHEXAS PHASE I MARYLAND STUDY--METALS IN WATER ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Water data set contains analytical results for measurements of up to 11 metals in 400 water samples over 80 households. One-liter samples of tap water were collected after a two minute flush from the tap identified by the resident as that most commonly used for dri...

  7. Copper in household drinking water in the city of Zagreb, Croatia.

    PubMed

    Pizent, Alica; Butković, Sanja

    2010-09-01

    Copper concentration was estimated in tap water samples obtained from 70 households in Zagreb, serviced by a public water supply system. First-draw and flushed samples of tap water were collected in the morning and total copper concentration was determined by graphite furnace atomic absorption spectrometry with Zeeman-effect background correction. We also estimated the contribution of plumbing material to copper concentrations in tap water. In households with copper pipes, median and range copper values were 310 μg L-1 [(27 to 632) μg L-1] in first-draw samples and 16 μg L-1 [(5 to 52) μg L-1] in flushed samples. Corresponding values for households with galvanised pipes were 140 μg L-1 [(11 to 289) μg L-1] and 8 μg L-1 [(1 to 42) μg L-1], respectively. Copper concentrations in household tap water in Zagreb were far below the proposed safe limits set by the Croatian and WHO regulations and EPA standards, and drinking water in Zagreb is not a significant source of copper exposure.

  8. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF DRINKING AND TAP WATER SAMPLES FOR VOCS (EPA METHOD 524.2) ANALYSIS (UA-F-18.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the collection, storage, and shipment of tap and drinking water samples for analysis by EPA method 524.2 (revision 4.0). This SOP provides a brief description of the sample containers, collection, preservation, storage, shipping, and custod...

  9. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE AND SHIPMENT OF DRINKING AND TAP WATER SAMPLES FOR TRACE METALS (EPA METHOD 200.8) (UA-F-16.1)

    EPA Science Inventory

    The purpose of this SOP is to describe how to collect, store, and ship tap and drinking water samples for analysis by EPA Method 200.8 (revision 4.4) for the NHEXAS Arizona project. This SOP provides a brief description of the sample containers, collection, preservation, storage...

  10. Microbial quality of drinking water from microfiltered water dispensers.

    PubMed

    Sacchetti, R; De Luca, G; Dormi, A; Guberti, E; Zanetti, F

    2014-03-01

    A comparison was made between the microbial quality of drinking water obtained from Microfiltered Water Dispensers (MWDs) and that of municipal tap water. A total of 233 water samples were analyzed. Escherichia coli (EC), enterococci (ENT), total coliforms (TC), Staphylococcus aureus, Pseudomonas aeruginosa and heterotrophic plate count (HPC) at 22 °C and 37 °C were enumerated. In addition, information was collected about the principal structural and functional characteristics of each MWD in order to study the various factors that might influence the microbial quality of the water. EC and ENT were not detected in any of the samples. TC were never detected in the tap water but were found in 5 samples taken from 5 different MWDs. S. aureus was found in a single sample of microfiltered water. P. aeruginosa was found more frequently and at higher concentrations in the samples collected from MWDs. The mean HPCs at 22 °C and 37 °C were significantly higher in microfiltered water samples compared to those of the tap water. In conclusion, the use of MWDs may increase the number of bacteria originally present in tap water. It is therefore important to monitor the quality of the dispensed water over time, especially if it is destined for vulnerable users. Copyright © 2013 Elsevier GmbH. All rights reserved.

  11. Evaluation of exposure to lead from drinking water in large buildings.

    PubMed

    Deshommes, Elise; Andrews, Robert C; Gagnon, Graham; McCluskey, Tim; McIlwain, Brad; Doré, Evelyne; Nour, Shokoufeh; Prévost, Michèle

    2016-08-01

    Lead results from 78,971 water samples collected in four Canadian provinces from elementary schools, daycares, and other large buildings using regulatory and investigative sampling protocols were analyzed to provide lead concentration distributions. Maximum concentrations reached 13,200 and 3890 μg/L following long and short stagnation periods respectively. High lead levels were persistent in some large buildings, reflected by high median values considering all taps, or specific to a few taps in the building. Simulations using the Integrated Uptake Biokinetic (IEUBK) model and lead concentrations after 30 min of stagnation in the dataset showed that, for most buildings, exposure to lead at the tap does not increase children's blood lead levels (BLLs). However, buildings or taps with extreme concentrations represent a significant health risk to young children attending school or daycare, as the estimated BLL far exceeded the 5 μg/dL threshold. Ingestion of water from specific taps could lead to acute exposure. Finally, for a few taps, the total daily lead intake reached the former World Health Organization (WHO) tolerable level for adults, suggesting potential health risks. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Rainwater harvesting in American Samoa: current practices and indicative health risks.

    PubMed

    Kirs, Marek; Moravcik, Philip; Gyawali, Pradip; Hamilton, Kerry; Kisand, Veljo; Gurr, Ian; Shuler, Christopher; Ahmed, Warish

    2017-05-01

    Roof-harvested rainwater (RHRW) is an important alternative source of water that many island communities can use for drinking and other domestic purposes when groundwater and/or surface water sources are contaminated, limited, or simply not available. The aim of this pilot-scale study was to investigate current RHRW practices in American Samoa (AS) and to evaluate and compare the quality of water from common potable water sources including RHRW stored in tanks, untreated stream water, untreated municipal well water, and treated municipal tap water samples. Samples were analyzed using culture-based methods, quantitative polymerase chain reaction (qPCR), and 16S amplicon sequencing-based methods. Based on indicator bacteria (total coliform and Escherichia coli) concentrations, the quality of RHRW was slightly lower than well and chlorinated tap water but exceeded that of untreated stream water. Although no Giardia or Leptospira spp. were detected in any of the RHRW samples, 86% of the samples were positive for Cryptosporidium spp. All stream water samples tested positive for Cryptosporidium spp. Opportunistic pathogens (Pseudomonas aeruginosa and Mycobacterium intracellulare) were also detected in the RHRW samples (71 and 21% positive samples, respectively). Several potentially pathogenic genera of bacteria were also detected in RHRW by amplicon sequencing. Each RHRW system was characterized by distinct microbial communities, 77% of operational taxonomic units (OTUs) were detected only in a single tank, and no OTU was shared by all the tanks. Risk of water-borne illness increased in the following order: chlorinated tap water/well water < RHRW < stream water. Frequent detection of opportunistic pathogens indicates that RHRW should be treated before use. Stakeholder education on RHRW system design options as well as on importance of regular cleaning and proper management techniques could improve the quality of the RHRW in AS.

  13. Growth of Finiteness in the Third Year of Life: Replication and Predictive Validity

    ERIC Educational Resources Information Center

    Hadley, Pamela A.; Rispoli, Matthew; Holt, Janet K.; Fitzgerald, Colleen; Bahnsen, Alison

    2014-01-01

    Purpose: The authors of this study investigated the validity of tense and agreement productivity (TAP) scoring in diverse sentence frames obtained during conversational language sampling as an alternative measure of finiteness for use with young children. Method: Longitudinal language samples were used to model TAP growth from 21 to 30 months of…

  14. Tapping mode imaging and measurements with an inverted atomic force microscope.

    PubMed

    Chan, Sandra S F; Green, John-Bruce D

    2006-07-18

    This report demonstrates the successful use of the inverted atomic force microscope (i-AFM) for tapping mode AFM imaging of cantilever-supported samples. i-AFM is a mode of AFM operation in which a sample supported on a tipless cantilever is imaged by one of many tips in a microfabricated tip array. Tapping mode is an intermittent contact mode whereby the cantilever is oscillated at or near its resonance frequency, and the amplitude and/or phase are used to image the sample. In the process of demonstrating that tapping mode images could be obtained in the i-AFM design, it was observed that the amplitude of the cantilever oscillation decreased markedly as the cantilever and tip array were approached. The source of this damping of the cantilever oscillations was identified to be the well-known "squeeze film damping", and the extent of damping was a direct consequence of the relatively shorter tip heights for the tip arrays, as compared to those of commercially available tapping mode cantilevers with integrated tips. The functional form for the distance dependence of the damping coefficient is in excellent agreement with previously published models for squeeze film damping, and the values for the fitting parameters make physical sense. Although the severe damping reduces the cantilever free amplitude substantially, we found that we were still able to access the low-amplitude regime of oscillation necessary for attractive tapping mode imaging of fragile molecules.

  15. A 3.9 ps Time-Interval RMS Precision Time-to-Digital Converter Using a Dual-Sampling Method in an UltraScale FPGA

    NASA Astrophysics Data System (ADS)

    Wang, Yonggang; Liu, Chong

    2016-10-01

    Field programmable gate arrays (FPGAs) manufactured with more advanced processing technology have faster carry chains and smaller delay elements, which are favorable for the design of tapped delay line (TDL)-style time-to-digital converters (TDCs) in FPGA. However, new challenges are posed in using them to implement TDCs with a high time precision. In this paper, we propose a bin realignment method and a dual-sampling method for TDC implementation in a Xilinx UltraScale FPGA. The former realigns the disordered time delay taps so that the TDC precision can approach the limit of its delay granularity, while the latter doubles the number of taps in the delay line so that the TDC precision beyond the cell delay limitation can be expected. Two TDC channels were implemented in a Kintex UltraScale FPGA, and the effectiveness of the new methods was evaluated. For fixed time intervals in the range from 0 to 440 ns, the average RMS precision measured by the two TDC channels reaches 5.8 ps using the bin realignment, and it further improves to 3.9 ps by using the dual-sampling method. The time precision has a 5.6% variation in the measured temperature range. Every part of the TDC, including dual-sampling, encoding, and on-line calibration, could run at a 500 MHz clock frequency. The system measurement dead time is only 4 ns.

  16. Electrodialytic in-line preconcentration for ionic solute analysis.

    PubMed

    Ohira, Shin-Ichi; Yamasaki, Takayuki; Koda, Takumi; Kodama, Yuko; Toda, Kei

    2018-04-01

    Preconcentration is an effective way to improve analytical sensitivity. Many types of methods are used for enrichment of ionic solute analytes. However, current methods are batchwise and include procedures such as trapping and elution. In this manuscript, we propose in-line electrodialytic enrichment of ionic solutes. The method can enrich ionic solutes within seconds by quantitative transfer of analytes from the sample solution to the acceptor solution under an electric field. Because of quantitative ion transfer, the enrichment factor (the ratio of the concentration in the sample and to that in the obtained acceptor solution) only depends on the flow rate ratio of the sample solution to the acceptor solution. The ratios of the concentrations and flow rates are equal for ratios up to 70, 20, and 70 for the tested ionic solutes of inorganic cations, inorganic anions, and heavy metal ions, respectively. The sensitivity of ionic solute determinations is also improved based on the enrichment factor. The method can also simultaneously achieve matrix isolation and enrichment. The method was successively applied to determine the concentrations of trace amounts of chloroacetic acids in tap water. The regulated concentration levels cannot be determined by conventional high-performance liquid chromatography with ultraviolet detection (HPLC-UV) without enrichment. However, enrichment with the present method is effective for determination of tap water quality by improving the limits of detection of HPLC-UV. The standard addition test with real tap water samples shows good recoveries (94.9-109.6%). Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Occurrence and variability of iodinated trihalomethanes concentrations within two drinking-water distribution networks.

    PubMed

    Ioannou, Panagiotis; Charisiadis, Pantelis; Andra, Syam S; Makris, Konstantinos C

    2016-02-01

    Non-iodo-containing trihalomethanes (TTHM) are frequently detected in chlorinated tap water and currently regulated against their carcinogenic potential. Iodinated THM (ITHM) may also form in disinfected with chlorine waters that are high in iodine content, but little is known about their magnitude and variability within the drinking-water pipe distribution network of urban areas. The main objective of this study was to determine the magnitude and variability of ITHM and TTHM levels and their corresponding daily intake estimates within the drinking water distribution systems of Limassol and Nicosia cities of Cyprus, using tap samples collected from individual households (n=37). In Limassol, mean household tap water ITHM and TTHM levels was 0.58 and 38 μg L(-1), respectively. Dichloroiodomethane (DCIM) was the dominant species of the two measured ITHM compounds accounting for 77% of total ITHM and in the range of 0.032 and 1.65 μg L(-1). The range of DCIM concentrations in Nicosia tap water samples was narrower (0.032 - 0.848 μg L(-1)). Mean total iodine concentration in tap water samples from the seaside city of Limassol was 15 μg L(-1) and approximately twice to those observed in samples from the mainland Nicosia city. However, iodine concentrations did not correlate with the ITHM levels. The calculated chronic daily intake rates of ITHM were low when compared with those of TTHM, but because of their widespread occurrence in tap water and their enhanced mammalian cell toxicity, additional research is warranted to assess the magnitude and variability of human ITHM exposures. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. What is the risk of infecting a cerebrospinal fluid-diverting shunt with percutaneous tapping?

    PubMed

    Spiegelman, Lindsey; Asija, Richa; Da Silva, Stephanie L; Krieger, Mark D; McComb, J Gordon

    2014-10-01

    Most CSF-diverting shunt systems have an access port that can be percutaneously tapped. Tapping the shunt can yield valuable information as to its function and whether an infection is present. The fear of causing a shunt infection by tapping may limit the physician's willingness to do so. The authors of this study investigate the risk of infecting a shunt secondary to percutaneous tapping. Following institutional review board approval, CSF specimens obtained from tapping an indwelling CSF-diverting shunt during the 2011 and 2012 calendar years were identified and matched with clinical information. A culture-positive CSF sample was defined as an infection. If results were equivocal, such as a broth-only-positive culture, a repeat CSF specimen was examined. The CSF was obtained by tapping the shunt access port with a 25-gauge butterfly needle after prepping the unshaven skin with chlorhexidine. During the study period, 266 children underwent 542 shunt taps. With 541 taps, no clinical evidence of a subsequent shunt infection was found. One child's CSF went from sterile to infected 11 days later; however, this patient had redness along the shunt tract at the time of the initial sterile tap. The risk of infection from tapping a shunt is remote if the procedure is done correctly.

  19. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF DRINKING AND TAP WATER SAMPLES FOR TRACE METALS (EPA METHOD 200.8) ANALYSIS (UA-F-16.1)

    EPA Science Inventory

    The purpose of this SOP is to describe how to collect, store, and ship tap and drinking water samples for analysis by EPA Method 200.8 (revision 4.4) for the NHEXAS Arizona project. This SOP provides a brief description of the sample containers, collection, preservation, storage...

  20. Determination of arsenic in ambient water at sub-part-per-trillion levels by hydride generation Pd coated platform collection and GFAAS detection.

    PubMed

    Liang, L; Lazoff, S; Chan, C; Horvat, M; Woods, J S

    1998-11-01

    A method for trace determination of total arsenic in ambient waters is described. Arsenic is separated on-line from a large volume water sample by hydride generation and purging, pre-collected on a Pd coated pyrolytic platform cuvette using a simple and inexpensive system, and finally detected by GFAAS. Instrument parameters, hydride generation, transportation, and collection were optimized. The analytical behavior for major species including As(3+), As(5+), monomethyl As (MMA), and dimethyl As (DMA) were investigated individually. Problems arising from use of the system were discussed and eliminated. The necessity of sample digestion and an efficient digestion method were studied. Sample digestion for water with low organic content such as tap water and clean ground water and some clean surface water can be omitted. The method detection limit (MDL) is 0.3 ng l(-1) for a 25 ml water sample. Recoveries close to 100% with R.S.D.<5% can be easily achieved. Typical aqueous samples including tap, ground, lake, river, rain, sewage effluent, and saline water from different origins in the US, China, and Canada were collected and analyzed using ultra clean sampling and analysis techniques. The background levels of As in most water analyzed were established for the first time, and found to be far above the EPA's health effect criteria, 18 ng l(-1).

  1. Clinical outcome in neonates with twin anemia-polycythemia sequence.

    PubMed

    Lopriore, Enrico; Slaghekke, Femke; Oepkes, Dick; Middeldorp, Johanna M; Vandenbussche, Frank P; Walther, Frans J

    2010-07-01

    The purpose of this study was to evaluate neonatal outcome of monochorionic twin pregnancies complicated by twin anemia-polycythemia sequence (TAPS). A cohort of consecutive monochorionic twins with TAPS with double survivors was included in the study. Each twin pair with TAPS was compared with 2 monochorionic twin pairs who were unaffected by TAPS or twin-to-twin transfusion syndrome and who were matched for gestational age at birth. Neonatal death, severe morbidity, and cerebral injury were studied. We included 19 twin pairs in the TAPS group and 38 control twin pairs. The incidence of neonatal death and severe neonatal morbidity was similar in the TAPS group and control group (3% [1/38] vs 1% [1/76] and 24% [9/38] vs 28% [21/76], respectively). Severe cerebral injury was detected in 1 infant (5%) in the TAPS group and 1 infant (2%) in the control group. Neonatal mortality and morbidity rates in a select population of TAPS neonates are similar to control neonatal rates. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  2. Molybdenum distributions and variability in drinking water from England and Wales.

    PubMed

    Smedley, P L; Cooper, D M; Lapworth, D J

    2014-10-01

    An investigation has been carried out of molybdenum in drinking water from a selection of public supply sources and domestic taps across England and Wales. This was to assess concentrations in relation to the World Health Organization (WHO) health-based value for Mo in drinking water of 70 μg/l and the decision to remove the element from the list of formal guideline values. Samples of treated drinking water from 12 water supply works were monitored up to four times over an 18-month period, and 24 domestic taps were sampled from three of their supply areas. Significant (p < 0.05) differences were apparent in Mo concentration between sources. Highest concentrations were derived from groundwater from a sulphide-mineralised catchment, although concentrations were only 1.5 μg/l. Temporal variability within sites was small, and no seasonal effects (p > 0.05) were detected. Tap water samples collected from three towns (North Wales, the English Midlands, and South East England) supplied uniquely by upland reservoir water, river water, and Chalk groundwater, respectively, also showed a remarkable uniformity in Mo concentrations at each location. Within each, the variability was very small between houses (old and new), between pre-flush and post-flush samples, and between the tap water and respective source water samples. The results indicate that water distribution pipework has a negligible effect on supplied tap water Mo concentrations. The findings contrast with those for Cu, Zn, Ni, Pb, and Cd, which showed significant differences (p < 0.05) in concentrations between pre-flush and post-flush tap water samples. In two pre-flush samples, concentrations of Ni or Pb were above drinking water limits, although in all cases, post-flush waters were compliant. The high concentrations, most likely derived from metal pipework in the domestic distribution system, accumulated during overnight stagnation. The concentrations of Mo observed in British drinking water, in all cases less than 2 μg/l, were more than an order of magnitude below the WHO health-based value and suggest that Mo is unlikely to pose a significant health or water supply problem in England and Wales.

  3. Multistate Evaluation of an Ultrafiltration-Based Procedure for Simultaneous Recovery of Enteric Microbes in 100-Liter Tap Water Samples▿

    PubMed Central

    Hill, Vincent R.; Kahler, Amy M.; Jothikumar, Narayanan; Johnson, Trisha B.; Hahn, Donghyun; Cromeans, Theresa L.

    2007-01-01

    Ultrafiltration (UF) is increasingly being recognized as a potentially effective procedure for concentrating and recovering microbes from large volumes of water and treated wastewater. Because of their very small pore sizes, UF membranes are capable of simultaneously concentrating viruses, bacteria, and parasites based on size exclusion. In this study, a UF-based water sampling procedure was used to simultaneously recover representatives of these three microbial classes seeded into 100-liter samples of tap water collected from eight cities covering six hydrologic areas of the United States. The UF-based procedure included hollow-fiber UF as the primary step for concentrating microbes and then used membrane filtration for bacterial culture assays, immunomagnetic separation for parasite recovery and quantification, and centrifugal UF for secondary concentration of viruses. Water samples were tested for nine water quality parameters to investigate whether water quality data correlated with measured recovery efficiencies and molecular detection levels. Average total method recovery efficiencies were 71, 97, 120, 110, and 91% for φX174 bacteriophage, MS2 bacteriophage, Enterococcus faecalis, Clostridium perfringens spores, and Cryptosporidium parvum oocysts, respectively. Real-time PCR and reverse transcription-PCR (RT-PCR) for seeded microbes and controls indicated that tap water quality could affect the analytical performance of molecular amplification assays, although no specific water quality parameter was found to correlate with reduced PCR or RT-PCR performance. PMID:17483281

  4. Microbiological evaluation of ready-to-eat iceberg lettuce during shelf-life and effectiveness of household washing methods

    PubMed Central

    Bencardino, Daniela; Vitali, Luca Agostino; Petrelli, Dezemona

    2018-01-01

    The aim of this study was to assess the microbiological quality of ready-to-eat (RTE) iceberg lettuce. Our investigation was based on the consumption tendency of university students considered a target market for this product. A total of 78 RTE samples were collected from chain supermarkets and analysed for the enumeration of aerobic mesophilic count (AMC), Escherichia coli and the detection of Salmonella spp. and Listeria monocytogenes. All samples were negative for the presence of pathogens. The mean value of AMC at the beginning, in the middle and after the expiration date was: 6.88, 8.51 and 8.72 log CFU g-1, respectively. The same investigation was performed on 12 samples of fresh iceberg lettuce samples. No pathogens were found and the mean value of AMC was lower than the RTE category (5.73 log CFU g-1; P<0.05). The effectiveness of 5 washing methods was determined on 15 samples of both fresh and RTE iceberg lettuce. Samples were washed for 15’ and 30’ in tap water (500 mL), tap water with NaCl (4 g/500 mL), tap water with bicarbonate (8 g/500 mL), tap water with vinegar (10 mL/500 mL) and tap water with chlorine-based disinfectant (10 mL/500 mL). A significant bacterial load reduction was recorded for vinegar and disinfectant after 30’ and 15’, respectively. Overall, these results showed that RTE iceberg lettuce is more contaminated than the fresh product. Also, the consumption in the first few days of packaging and after washing with disinfectants reduces the risk for health consumers. PMID:29732325

  5. Quality comparison of tap water vs. bottled water in the industrial city of Yanbu (Saudi Arabia).

    PubMed

    Ahmad, Maqbool; Bajahlan, Ahmad S

    2009-12-01

    This study was conducted to compare the quality of bottled water with potabilized desalinated tap water. Fourteen brands of local and imported bottled water samples were collected from the local market and analyzed for physicochemical parameters in the Royal Commission Environmental Laboratory. Results were compared with 5-year continuous monitoring data of tap water from different locations in Madinat Yanbu Al-Sinaiyah (MYAS) including storage tanks of desalination plant. Results show that there was no significant difference in the quality of tap water and bottled water. Bacteriological test was never found positive in the 5-year data in tap water. Similarly, physicochemical analysis shows the persistent quality of tap water. Based on hardness analysis, bottled and tap water are categorized as soft water. Trihalomethanes (THMs) study also indicates that traces of disinfection by products (DBPs) are present in both tap and bottled water and are much less than the World Health Organization and Environmental Protection Agency maximum permissible limits. It is also important to note that the tap water distribution network in MAYS is a high-pressure recirculation network and there is no chance to grow bacteria in stagnant water in pipe lines or houses. Recently, the Royal Commission has replaced the whole drinking water network, which was made of asbestos-cemented pipes with glass-reinforced plastic (GRP) pipes, to avoid any asbestos contaminations. Based on these results, it is concluded that drinking water distributed in the city is of very good and persistent quality, comparable with bottled water. Continuous monitoring also guarantees the safe drinking water to the community. Hence, it is the responsibility of the Royal Commission to encourage the peoples in the city to drink tap water as it is as good as bottled water even better than some of the brands and is monitored regularly. It is also much cheaper compared to bottled water and is available round the clock. Preference for tap water over bottled water will also reduce the production of bottled water that has flooded the market, the enormous strain on the environment, and the pollution due to used empty plastic bottles in the landfill area and will help to keep the city clean.

  6. 40 CFR 63.1652 - Emission standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (including primary and tapping) containing particulate matter in excess of one of the following: (1) 0.23... from any existing open submerged arc furnace exhaust gases (including primary and tapping) containing... primary, tapping, and vent stacks) containing particulate matter in excess of 11.2 kg/hr (24.7 lb/hr) when...

  7. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF DRINKING AND TAP WATER SAMPLES FOR PESTICIDES (EPA 225.2) AND CARBARYL (EPA 531.1) ANALYSIS (UA-F-17.1)

    EPA Science Inventory

    The purpose of this SOP is to describe how to collect, store, and ship tap and drinking water samples for analysis by EPA Method 525.2 (revision 1.0) and EPA method 531.1 (revision 3). This SOP provides a brief description of the sample containers, collection, preservation, stor...

  8. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE AND SHIPMENT OF DRINKING AND TAP WATER SAMPLES FOR PESTICIDES (EPA 225.2) AND CARBARYL (EPA 531.1) (UA-F-17.1)

    EPA Science Inventory

    The purpose of this SOP is to describe how to collect, store, and ship tap and drinking water samples for analysis by EPA Method 525.2 (revision 1.0) and EPA method 531.1 (revision 3) for the NHEXAS Arizona project. This SOP provides a brief description of the sample containers,...

  9. Groundwater-quality data in the Monterey–Salinas shallow aquifer study unit, 2013: Results from the California GAMA Program

    USGS Publications Warehouse

    Goldrath, Dara A.; Kulongoski, Justin T.; Davis, Tracy A.

    2016-09-01

    Groundwater quality in the 3,016-square-mile Monterey–Salinas Shallow Aquifer study unit was investigated by the U.S. Geological Survey (USGS) from October 2012 to May 2013 as part of the California State Water Resources Control Board Groundwater Ambient Monitoring and Assessment (GAMA) Program’s Priority Basin Project. The GAMA Monterey–Salinas Shallow Aquifer study was designed to provide a spatially unbiased assessment of untreated-groundwater quality in the shallow-aquifer systems in parts of Monterey and San Luis Obispo Counties and to facilitate statistically consistent comparisons of untreated-groundwater quality throughout California. The shallow-aquifer system in the Monterey–Salinas Shallow Aquifer study unit was defined as those parts of the aquifer system shallower than the perforated depth intervals of public-supply wells, which generally corresponds to the part of the aquifer system used by domestic wells. Groundwater quality in the shallow aquifers can differ from the quality in the deeper water-bearing zones; shallow groundwater can be more vulnerable to surficial contamination.Samples were collected from 170 sites that were selected by using a spatially distributed, randomized grid-based method. The study unit was divided into 4 study areas, each study area was divided into grid cells, and 1 well was sampled in each of the 100 grid cells (grid wells). The grid wells were domestic wells or wells with screen depths similar to those in nearby domestic wells. A greater spatial density of data was achieved in 2 of the study areas by dividing grid cells in those study areas into subcells, and in 70 subcells, samples were collected from exterior faucets at sites where there were domestic wells or wells with screen depths similar to those in nearby domestic wells (shallow-well tap sites).Field water-quality indicators (dissolved oxygen, water temperature, pH, and specific conductance) were measured, and samples for analysis of inorganic constituents (trace elements, nutrients, major and minor ions, silica, total dissolved solids, and alkalinity) were collected at all 170 sites. In addition to these constituents, the samples from grid wells were analyzed for organic constituents (volatile organic compounds, pesticides and pesticide degradates), constituents of special interest (perchlorate and N-nitrosodimethylamine, or NDMA), radioactive constituents (radon-222 and gross-alpha and gross-beta radioactivity), and geochemical and age-dating tracers (stable isotopes of carbon in dissolved inorganic carbon, carbon-14 abundances, stable isotopes of hydrogen and oxygen in water, and tritium activities).Three types of quality-control samples (blanks, replicates, and matrix spikes) were collected at up to 11 percent of the wells in the Monterey–Salinas Shallow Aquifer study unit, and the results for these samples were used to evaluate the quality of the data from the groundwater samples. With the exception of trace elements, blanks rarely contained detectable concentrations of any constituent, indicating that contamination from sample-collection procedures was not a significant source of bias in the data for the groundwater samples. Low concentrations of some trace elements were detected in blanks; therefore, the data were re-censored at higher reporting levels. Replicate samples generally were within the limits of acceptable analytical reproducibility. The median values of matrix-spike recoveries were within the acceptable range (70 to 130 percent) for the volatile organic compounds (VOCs) and N-nitrosodimethylamine (NDMA), but were only approximately 64 percent for pesticides and pesticide degradates.The sample-collection protocols used in this study were designed to obtain representative samples of groundwater. The quality of groundwater can differ from the quality of drinking water because water chemistry can change as a result of contact with plumbing systems or the atmosphere; because of treatment, disinfection, or blending with water from other sources; or some combination of these. Water quality in domestic wells is not regulated in California, however, to provide context for the water-quality data presented in this report, results were compared to benchmarks established for drinking-water quality. The primary comparison benchmarks were maximum contaminant levels established by the U.S. Environmental Protection Agency and the State of California (MCL-US and MCL-CA, respectively). Non-regulatory benchmarks were used for constituents without maximum contaminant levels (MCLs), including Health Based Screening Levels (HBSLs) developed by the USGS and State of California secondary maximum contaminant levels (SMCL-CA) and notification levels. Most constituents detected in samples from the Monterey–Salinas Shallow Aquifer study unit had concentrations less than their respective benchmarks.Of the 148 organic constituents analyzed in the 100 grid-well samples, 38 were detected, and all concentrations were less than the benchmarks. Volatile organic compounds were detected in 26 of the grid wells, and pesticides and pesticide degradates were detected in 28 grid wells. The special-interest constituent NDMA was detected above the HBSL in three samples, one of which also had a perchlorate concentration greater than the MCL-CA.Of the inorganic constituents, 6 were detected at concentrations above their respective MCL benchmarks in grid-well samples: arsenic (5 grid wells above the MCL of 10 micrograms per liter, μg/L), selenium (3 grid wells, MCL of 50 μg/L), uranium (4 grid wells, MCL of 30 μg/L), nitrate (16 grid wells, MCL of 10 milligrams per liter, mg/L), adjusted gross alpha particle activity (10 grid wells, MCL of 15 picocuries per liter, pCi/L), and gross beta particle activity (1 grid well, MCL of 50 pCi/L). An additional 4 inorganic constituents were detected at concentrations above their respective HBSL benchmarks in grid-well samples: boron (1 grid well above the HBSL of 6,000 μg/L), manganese (8 grid wells, HBSL of 300 μg/L), molybdenum (6 grid wells, HBSL of 40 μg/L), and strontium (6 grid wells, HBSL of 4,000 μg/L). Of the inorganic constituents, 4 were detected at concentrations above their non-health based SMCL benchmarks in grid-well samples: iron (9 grid wells above the SMCL of 300 μg/L), chloride (7 grid wells, SMCL of 500 mg/L), sulfate (14 grid wells, SMCL of 500 mg/L), and total dissolved solids (27 grid wells, SMCL of 1,000 mg/L).Of the inorganic constituents analyzed in the 70 shallow-well tap sites, 10 were detected at concentrations above the benchmarks. Of the inorganic constituents, 3 were detected at concentrations above their respective MCL benchmarks in shallow-well tap sites: arsenic (2 shallow-well tap sites above the MCL of 10 μg/L), uranium (2 shallow-well tap sites, MCL of 30 μg/L), and nitrate (24 shallow-well tap sites, MCL of 10 mg/L). An additional 3 inorganic constituents were detected above their respective HBSL benchmarks in shallow-well tap sites: manganese (4 shallow-well tap sites above the HBSL of 300 μg/L), molybdenum (4 shallow-well tap sites, HBSL of 40 μg/L), and zinc (2 shallow-well tap sites, HBSL of 2,000 μg/L). Of the inorganic constituents, 4 were detected at concentrations above their non-health based SMCL benchmarks in shallow-well tap sites: iron (6 shallow-well tap sites above the SMCL of 300 μg/L), chloride (1 shallow-well tap site, SMCL of 500 mg/L), sulfate (9 shallow-well tap sites, SMCL of 500 mg/L), and total dissolved solids (15 shallow-well tap sites, SMCL of 1,000 mg/L).

  10. Occurrence of bisphenol A in surface water, drinking water and plasma from Malaysia with exposure assessment from consumption of drinking water.

    PubMed

    Santhi, V A; Sakai, N; Ahmad, E D; Mustafa, A M

    2012-06-15

    This study investigated the level of bisphenol A (BPA) in surface water used as potable water, drinking water (tap and bottled mineral water) and human plasma in the Langat River basin, Malaysia. BPA was present in 93% of the surface water samples at levels ranging from below limit of quantification (LOQ; 1.3 ng/L) to 215 ng/L while six fold higher levels were detected in samples collected near industrial and municipal sewage treatment plant outlets. Low levels of BPA were detected in most of the drinking water samples. BPA in tap water ranged from 3.5 to 59.8 ng/L with the highest levels detected in samples collected from taps connected to PVC pipes and water filter devices. Bottled mineral water had lower levels of BPA (3.3±2.6 ng/L) although samples stored in poor storage condition had significantly higher levels (11.3±5.3 ng/L). Meanwhile, only 17% of the plasma samples had detectable levels of BPA ranging from 0.81 to 3.65 ng/mL. The study shows that BPA is a ubiquitous contaminant in surface, tap and bottled mineral water. However, exposure to BPA from drinking water is very low and is less than 0.01% of the tolerable daily intake (TDI). Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Predicting consumer preferences for mineral composition of bottled and tap water.

    PubMed

    Platikanov, Stefan; Hernández, Alejandra; González, Susana; Luis Cortina, Jose; Tauler, Roma; Devesa, Ricard

    2017-01-01

    The overall liking for taste of water was correlated with the mineral composition of selected bottled and tap waters. Sixty-nine untrained volunteers assessed and rated twenty-five different commercial bottled and tap waters from. Water samples were physicochemical characterised by analysing conductivity, pH, total dissolved solids (TDS) and major anions and cations: HCO 3 - , SO 4 2- , Cl - , NO 3 - , Ca 2+ , Mg 2+ , Na + , and K + . Residual chlorine levels were also analysed in the tap water samples. Globally, volunteers preferred waters rich in calcium bicarbonate and sulfate, rather than in sodium chloride. This study also demonstrated that it was possible to accurately predict the overall liking by a Partial Least Squares regression using either all measured physicochemical parameters or a reduced number of them. These results were in agreement with previously published results using trained panellists. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Sampling Methods for Detection and Monitoring of the Asian Citrus Psyllid (Hemiptera: Psyllidae).

    PubMed

    Monzo, C; Arevalo, H A; Jones, M M; Vanaclocha, P; Croxton, S D; Qureshi, J A; Stansly, P A

    2015-06-01

    The Asian citrus psyllid (ACP), Diaphorina citri Kuwayama is a key pest of citrus due to its role as vector of citrus greening disease or "huanglongbing." ACP monitoring is considered an indispensable tool for management of vector and disease. In the present study, datasets collected between 2009 and 2013 from 245 citrus blocks were used to evaluate precision, sensitivity for detection, and efficiency of five sampling methods. The number of samples needed to reach a 0.25 standard error-mean ratio was estimated using Taylor's power law and used to compare precision among sampling methods. Comparison of detection sensitivity and time expenditure (cost) between stem-tap and other sampling methodologies conducted consecutively at the same location were also assessed. Stem-tap sampling was the most efficient sampling method when ACP densities were moderate to high and served as the basis for comparison with all other methods. Protocols that grouped trees near randomly selected locations across the block were more efficient than sampling trees at random across the block. Sweep net sampling was similar to stem-taps in number of captures per sampled unit, but less precise at any ACP density. Yellow sticky traps were 14 times more sensitive than stem-taps but much more time consuming and thus less efficient except at very low population densities. Visual sampling was efficient for detecting and monitoring ACP at low densities. Suction sampling was time consuming and taxing but the most sensitive of all methods for detection of sparse populations. This information can be used to optimize ACP monitoring efforts. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Passive Resonant Bidirectional Converter with Galvanic Barrier

    NASA Technical Reports Server (NTRS)

    Rosenblad, Nathan S. (Inventor)

    2014-01-01

    A passive resonant bidirectional converter system that transports energy across a galvanic barrier includes a converter using at least first and second converter sections, each section including a pair of transfer terminals, a center tapped winding; a chopper circuit interconnected between the center tapped winding and one of the transfer terminals; an inductance feed winding interconnected between the other of the transfer terminals and the center tap and a resonant tank circuit including at least the inductance of the center tap winding and the parasitic capacitance of the chopper circuit for operating the converter section at resonance; the center tapped windings of the first and second converter sections being disposed on a first common winding core and the inductance feed windings of the first and second converter sections being disposed on a second common winding core for automatically synchronizing the resonant oscillation of the first and second converter sections and transferring energy between the converter sections until the voltage across the pairs of transfer terminals achieves the turns ratio of the center tapped windings.

  14. Anthropogenic contamination of tap water, beer, and sea salt

    PubMed Central

    2018-01-01

    Plastic pollution has been well documented in natural environments, including the open waters and sediments within lakes and rivers, the open ocean and even the air, but less attention has been paid to synthetic polymers in human consumables. Since multiple toxicity studies indicate risks to human health when plastic particles are ingested, more needs to be known about the presence and abundance of anthropogenic particles in human foods and beverages. This study investigates the presence of anthropogenic particles in 159 samples of globally sourced tap water, 12 brands of Laurentian Great Lakes beer, and 12 brands of commercial sea salt. Of the tap water samples analyzed, 81% were found to contain anthropogenic particles. The majority of these particles were fibers (98.3%) between 0.1–5 mm in length. The range was 0 to 61 particles/L, with an overall mean of 5.45 particles/L. Anthropogenic debris was found in each brand of beer and salt. Of the extracted particles, over 99% were fibers. After adjusting for particles found in lab blanks for both salt and beer, the average number of particles found in beer was 4.05 particles/L with a range of 0 to 14.3 particles/L and the average number of particles found in each brand of salt was 212 particles/kg with a range of 46.7 to 806 particles/kg. Based on consumer guidelines, our results indicate the average person ingests over 5,800 particles of synthetic debris from these three sources annually, with the largest contribution coming from tap water (88%). PMID:29641556

  15. Genetic Variants in TAP Are Associated with High-Grade Cervical Neoplasia

    PubMed Central

    Einstein, Mark H.; Leanza, Suzanne; Chiu, Lydia G.; Schlecht, Nicolas F.; Goldberg, Gary L.; Steinberg, Bettie M.; Burk, Robert D.

    2018-01-01

    Purpose The transporter associated with antigen processing (TAP) is essential in assembling MHC-I proteins. Human papillomavirus (HPV) evades immune recognition by decreasing class I MHC cell surface expression through down-regulation of TAP1 levels. Consistent with heterogeneity in MHC expression is the individual variability in clearing detectable HPV infections. Genetic polymorphisms in TAP genes may affect protein structure, function, and the ability to clear HPV infection. Experimental Design Case-control study of women with cervical intraepithelial neoplasia (CIN) II or III (n = 114) and women without high-grade CIN (n = 366). Five nonsynonymous single nucleotide polymorphisms (SNP) in TAP1 and TAP2 were genotyped using DNA collected in cervicovaginal lavage samples using microsphere array technology (Luminex ×MAP). HPV typing was done using a PCR-based system with MY09/MY11 primers. TAP1 and TAP2 SNPs were validated by direct sequencing. Results Differences in allele distribution between women with high-grade cervical neoplasia and women without was seen for TAP1 I333V (P = 0.02) and TAP1 D637G (p = 0.01).The odds ratios (OR) for CIN III were significantly lower among carriers of the TAP1 I333V polymorphism (OR, 0.28; 95% confidence interval, 0.1-0.8), and TAP1 D637G polymorphism (OR, 0.27; 95% confidence interval, 0.1-0.7). These associations remained significant even after restricting the evaluation to women who were positive for high-risk HPV types. Conclusions In addition to the down-regulation of MHC-1 by oncogenic HPV, HPV pathogenesis might be facilitated by polymorphisms in the TAP proteins. Identifying TAP polymorphisms may potentially be used to identify women less susceptible to progression to high-grade CIN and cervical cancer. PMID:19188174

  16. Onsite Gaseous Centrifuge Enrichment Plant UF6 Cylinder Destructive Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anheier, Norman C.; Cannon, Bret D.; Qiao, Hong

    2012-07-17

    The IAEA safeguards approach for gaseous centrifuge enrichment plants (GCEPs) includes measurements of gross, partial, and bias defects in a statistical sampling plan. These safeguard methods consist principally of mass and enrichment nondestructive assay (NDA) verification. Destructive assay (DA) samples are collected from a limited number of cylinders for high precision offsite mass spectrometer analysis. DA is typically used to quantify bias defects in the GCEP material balance. Under current safeguards measures, the operator collects a DA sample from a sample tap following homogenization. The sample is collected in a small UF6 sample bottle, then sealed and shipped under IAEAmore » chain of custody to an offsite analytical laboratory. Current practice is expensive and resource intensive. We propose a new and novel approach for performing onsite gaseous UF6 DA analysis that provides rapid and accurate assessment of enrichment bias defects. DA samples are collected using a custom sampling device attached to a conventional sample tap. A few micrograms of gaseous UF6 is chemically adsorbed onto a sampling coupon in a matter of minutes. The collected DA sample is then analyzed onsite using Laser Ablation Absorption Ratio Spectrometry-Destructive Assay (LAARS-DA). DA results are determined in a matter of minutes at sufficient accuracy to support reliable bias defect conclusions, while greatly reducing DA sample volume, analysis time, and cost.« less

  17. Transversus abdominis plane (TAP) block in laparoscopic colorectal surgery improves postoperative pain management: a meta-analysis.

    PubMed

    Hain, E; Maggiori, L; Prost À la Denise, J; Panis, Y

    2018-04-01

    Transversus abdominis plane (TAP) block is a locoregional anaesthesia technique of growing interest in abdominal surgery. However, its efficacy following laparoscopic colorectal surgery is still debated. This meta-analysis aimed to assess the efficacy of TAP block after laparoscopic colorectal surgery. All comparative studies focusing on TAP block after laparoscopic colorectal surgery have been systematically identified through the MEDLINE database, reviewed and included. Meta-analysis was performed according to the Mantel-Haenszel method for random effects. End-points included postoperative opioid consumption, morbidity, time to first bowel movement and length of hospital stay. A total of 13 studies, including 7 randomized controlled trials, were included, comprising a total of 600 patients who underwent laparoscopic colorectal surgery with TAP block, compared with 762 patients without TAP block. Meta-analysis of these studies showed that TAP block was associated with a significantly reduced postoperative opioid consumption on the first day after surgery [weighted mean difference (WMD) -14.54 (-25.14; -3.94); P = 0.007] and a significantly shorter time to first bowel movement [WMD -0.53 (-0.61; -0.44); P < 0.001] but failed to show any impact on length of hospital stay [WMD -0.32 (-0.83; 0.20); P = 0.23] although no study considered length of stay as its primary outcome. Finally, TAP block was not associated with a significant increase in the postoperative overall complication rate [OR = 0.84 (0.62-1.14); P = 0.27]. Transversus abdominis plane (TAP) block in laparoscopic colorectal surgery improves postoperative opioid consumption and recovery of postoperative digestive function without any significant drawback. Colorectal Disease © 2018 The Association of Coloproctology of Great Britain and Ireland.

  18. Associations between Perceptions of Drinking Water Service Delivery and Measured Drinking Water Quality in Rural Alabama

    PubMed Central

    Wedgworth, Jessica C.; Brown, Joe; Johnson, Pauline; Olson, Julie B.; Elliott, Mark; Forehand, Rick; Stauber, Christine E.

    2014-01-01

    Although small, rural water supplies may present elevated microbial risks to consumers in some settings, characterizing exposures through representative point-of-consumption sampling is logistically challenging. In order to evaluate the usefulness of consumer self-reported data in predicting measured water quality and risk factors for contamination, we compared matched consumer interview data with point-of-survey, household water quality and pressure data for 910 households served by 14 small water systems in rural Alabama. Participating households completed one survey that included detailed feedback on two key areas of water service conditions: delivery conditions (intermittent service and low water pressure) and general aesthetic characteristics (taste, odor and color), providing five condition values. Microbial water samples were taken at the point-of-use (from kitchen faucets) and as-delivered from the distribution network (from outside flame-sterilized taps, if available), where pressure was also measured. Water samples were analyzed for free and total chlorine, pH, turbidity, and presence of total coliforms and Escherichia coli. Of the 910 households surveyed, 35% of participants reported experiencing low water pressure, 15% reported intermittent service, and almost 20% reported aesthetic problems (taste, odor or color). Consumer-reported low pressure was associated with lower gauge-measured pressure at taps. While total coliforms (TC) were detected in 17% of outside tap samples and 12% of samples from kitchen faucets, no reported water service conditions or aesthetic characteristics were associated with presence of TC. We conclude that consumer-reported data were of limited utility in predicting potential microbial risks associated with small water supplies in this setting, although consumer feedback on low pressure—a risk factor for contamination—may be relatively reliable and therefore useful in future monitoring efforts. PMID:25046635

  19. Associations between perceptions of drinking water service delivery and measured drinking water quality in rural Alabama.

    PubMed

    Wedgworth, Jessica C; Brown, Joe; Johnson, Pauline; Olson, Julie B; Elliott, Mark; Forehand, Rick; Stauber, Christine E

    2014-07-18

    Although small, rural water supplies may present elevated microbial risks to consumers in some settings, characterizing exposures through representative point-of-consumption sampling is logistically challenging. In order to evaluate the usefulness of consumer self-reported data in predicting measured water quality and risk factors for contamination, we compared matched consumer interview data with point-of-survey, household water quality and pressure data for 910 households served by 14 small water systems in rural Alabama. Participating households completed one survey that included detailed feedback on two key areas of water service conditions: delivery conditions (intermittent service and low water pressure) and general aesthetic characteristics (taste, odor and color), providing five condition values. Microbial water samples were taken at the point-of-use (from kitchen faucets) and as-delivered from the distribution network (from outside flame-sterilized taps, if available), where pressure was also measured. Water samples were analyzed for free and total chlorine, pH, turbidity, and presence of total coliforms and Escherichia coli. Of the 910 households surveyed, 35% of participants reported experiencing low water pressure, 15% reported intermittent service, and almost 20% reported aesthetic problems (taste, odor or color). Consumer-reported low pressure was associated with lower gauge-measured pressure at taps. While total coliforms (TC) were detected in 17% of outside tap samples and 12% of samples from kitchen faucets, no reported water service conditions or aesthetic characteristics were associated with presence of TC. We conclude that consumer-reported data were of limited utility in predicting potential microbial risks associated with small water supplies in this setting, although consumer feedback on low pressure-a risk factor for contamination-may be relatively reliable and therefore useful in future monitoring efforts.

  20. High speed transient sampler

    DOEpatents

    McEwan, T.E.

    1995-11-28

    A high speed sampler comprises a meandered sample transmission line for transmitting an input signal, a straight strobe transmission line for transmitting a strobe signal, and a plurality of sampling gates along the transmission lines. The sampling gates comprise a four terminal diode bridge having a first strobe resistor connected from a first terminal of the bridge to the positive strobe line, a second strobe resistor coupled from the third terminal of the bridge to the negative strobe line, a tap connected to the second terminal of the bridge and to the sample transmission line, and a sample holding capacitor connected to the fourth terminal of the bridge. The resistance of the first and second strobe resistors is much higher than the signal transmission line impedance in the preferred system. This results in a sampling gate which applies a very small load on the sample transmission line and on the strobe generator. The sample holding capacitor is implemented using a smaller capacitor and a larger capacitor isolated from the smaller capacitor by resistance. The high speed sampler of the present invention is also characterized by other optimizations, including transmission line tap compensation, stepped impedance strobe line, a multi-layer physical layout, and unique strobe generator design. A plurality of banks of such samplers are controlled for concatenated or interleaved sample intervals to achieve long sample lengths or short sample spacing. 17 figs.

  1. High speed transient sampler

    DOEpatents

    McEwan, Thomas E.

    1995-01-01

    A high speed sampler comprises a meandered sample transmission line for transmitting an input signal, a straight strobe transmission line for transmitting a strobe signal, and a plurality of sampling gates along the transmission lines. The sampling gates comprise a four terminal diode bridge having a first strobe resistor connected from a first terminal of the bridge to the positive strobe line, a second strobe resistor coupled from the third terminal of the bridge to the negative strobe line, a tap connected to the second terminal of the bridge and to the sample transmission line, and a sample holding capacitor connected to the fourth terminal of the bridge. The resistance of the first and second strobe resistors is much higher than the signal transmission line impedance in the preferred system. This results in a sampling gate which applies a very small load on the sample transmission line and on the strobe generator. The sample holding capacitor is implemented using a smaller capacitor and a larger capacitor isolated from the smaller capacitor by resistance. The high speed sampler of the present invention is also characterized by other optimizations, including transmission line tap compensation, stepped impedance strobe line, a multi-layer physical layout, and unique strobe generator design. A plurality of banks of such samplers are controlled for concatenated or interleaved sample intervals to achieve long sample lengths or short sample spacing.

  2. Natural radioactivity in various water samples and radiation dose estimations in Bolu province, Turkey.

    PubMed

    Gorur, F Korkmaz; Camgoz, H

    2014-10-01

    The level of natural radioactivity for Bolu province of north-western Turkey was assessed in this study. There is no information about radioactivity measurement reported in water samples in the Bolu province so far. For this reason, gross α and β activities of 55 different water samples collected from tap, spring, mineral, river and lake waters in Bolu were determined. The mean activity concentrations were 68.11 mBq L(-1), 169.44 mBq L(-1) for gross α and β in tap water. For all samples the gross β activity is always higher than the gross α activity. All value of the gross α were lower than the limit value of 500 mBq L(-1) while two spring and one mineral water samples were found to have gross β activity concentrations of greater than 1000 mBq L(-1). The associated age-dependent dose from all water ingestion in Bolu was estimated. The total dose for adults had an average value exceeds the WHO recommended limit value. The risk levels from the direct ingestion of the natural radionuclides in tap and mineral water in Bolu were determinated. The mean (210)Po and (228)Ra risk the value of tap and mineral waters slightly exceeds what some consider on acceptable risk of 10(-4) or less. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Drinking water quality assessment.

    PubMed

    Aryal, J; Gautam, B; Sapkota, N

    2012-09-01

    Drinking water quality is the great public health concern because it is a major risk factor for high incidence of diarrheal diseases in Nepal. In the recent years, the prevalence rate of diarrhoea has been found the highest in Myagdi district. This study was carried out to assess the quality of drinking water from different natural sources, reservoirs and collection taps at Arthunge VDC of Myagdi district. A cross-sectional study was carried out using random sampling method in Arthunge VDC of Myagdi district from January to June,2010. 84 water samples representing natural sources, reservoirs and collection taps from the study area were collected. The physico-chemical and microbiological analysis was performed following standards technique set by APHA 1998 and statistical analysis was carried out using SPSS 11.5. The result was also compared with national and WHO guidelines. Out of 84 water samples (from natural source, reservoirs and tap water) analyzed, drinking water quality parameters (except arsenic and total coliform) of all water samples was found to be within the WHO standards and national standards.15.48% of water samples showed pH (13) higher than the WHO permissible guideline values. Similarly, 85.71% of water samples showed higher Arsenic value (72) than WHO value. Further, the statistical analysis showed no significant difference (P<0.05) of physico-chemical parameters and total coliform count of drinking water for collection taps water samples of winter (January, 2010) and summer (June, 2010). The microbiological examination of water samples revealed the presence of total coliform in 86.90% of water samples. The results obtained from physico-chemical analysis of water samples were within national standard and WHO standards except arsenic. The study also found the coliform contamination to be the key problem with drinking water.

  4. Microbiological tap water profile of a medium-sized building and effect of water stagnation.

    PubMed

    Lipphaus, Patrick; Hammes, Frederik; Kötzsch, Stefan; Green, James; Gillespie, Simon; Nocker, Andreas

    2014-01-01

    Whereas microbiological quality of drinking water in water distribution systems is routinely monitored for reasons of legal compliance, microbial numbers in tap water are grossly understudied. Motivated by gross differences in water from private households, we applied in this study flow cytometry as a rapid analytical method to quantify microbial concentrations in water sampled at diverse taps in a medium size research building receiving chlorinated water. Taps differed considerably in frequency of usage and were located in laboratories, bathrooms, and a coffee kitchen. Substantial differences were observed between taps with concentrations (per mL) in the range from 6.29 x 10(3) to 7.74 x 10(5) for total cells and from 1.66 x 10(3) to 4.31 x 10(5) for intact cells. The percentage of intact cells varied between 7% and 96%. Water from taps with very infrequent use showed the highest bacterial numbers and the highest proportions of intact cells. Stagnation tended to increase microbial numbers in water from those taps which were otherwise frequently used. Microbial numbers in other taps that were rarely opened were not affected by stagnation as their water is probably mostly stagnant. For cold water taps, microbial numbers and the percentage of intact cells tended to decline with flushing with the greatest decline for taps used least frequently whereas microbial concentrations in water from hot water taps tended to be somewhat more stable. We conclude that microbiological water quality is mainly determined by building-specific parameters. Tap water profiling can provide valuable insight into plumbing system hygiene and maintenance.

  5. A level change in mutagenicity of Japanese tap water over the past 12 yr.

    PubMed

    Takanashi, Hirokazu; Kishida, Misako; Nakajima, Tsunenori; Ohki, Akira; Akiba, Michihiro

    2011-05-01

    A relative comparison study of mutagenicity in Japanese tap water was conducted for 1993 and 2005 surveys. It intended to assess the effects of advanced water treatment installations to water works, improvement of raw water quality and improvement of residual HOCl concentration controlling. Sampling points (taps) were the same in both surveys. The results of 245 samples obtained by the Ames Salmonella mutagenicity test (Ames test) were analyzed. The Ames tests were conducted by using Salmonella typhimurium TA98 and TA100 strains with and without exogenous activation (S9). With the exception of TA100-S9, the other conditions needed no discussion as a factor in the mutagenicity level change. The average mutagenicity in 1993 and 2005 under the conditions of TA100-S9 were 2600 and 1100 net revertantL(-1), respectively. This indicated that the mutagenicity level of Japanese tap water decreased during the 12-yr period. Particularly a remarkable decrease in mutagenicity was observed in the water works where the advanced water treatments were installed during the 12-yr period. The advanced water treatments were effective in decreasing the mutagenicity of tap water. Mutagenicity also decreased in the water works with conventional water treatments; the improvement of residual HOCl concentration controlling was also considered to be effective in decreasing the mutagenicity of tap water. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Effect of immersion chilling of broiler chicken carcasses in monochloramine on lipid oxidation and halogenated residual compound formation.

    PubMed

    Axtell, Stephen P; Russell, Scott M; Berman, Elliot

    2006-04-01

    This study was conducted to evaluate the effect of immersion chilling of broiler chicken carcasses in tap water (TAP) or TAP containing 50 ppm of monochloramine (MON) with respect to chloroform formation, total chlorine content, 2-thiobarbituric acid (TBA) values, and fatty acid profiles. Ten broiler chicken carcasses were chilled in TAP or MON for 6 h. After exposure, the carcasses were removed and cut in half along the median plane into right and left halves. After roasting the left halves, samples of the breast, thigh, and skin (with fat) were collected, subjected to fatty acid profiling, and assayed for chloroform, total chlorine, and TBA. The uncooked right halves of each carcass were stored at 4 degrees C for 10 days and then roasted. After roasting these right halves, samples of breast, thigh, and skin (with fat) were collected from each carcass half, subjected to fatty acid profiling, and assayed for chloroform, total chlorine, and TBA. There were no statistical differences between TAP- and MON-treated fresh or stored products with regard to chloroform levels, total chlorine content, TBA values, or fatty acid profiles.

  7. Transportation Air Pollution Studies (TAPS) System

    DOT National Transportation Integrated Search

    1974-03-01

    This report describes the Transportation Air Pollution Studies (TAPS) Data Base and the Software System which has been developed in association with it. : The TAPS Data Base will be used to store the transportation air pollution data (including emiss...

  8. Probing and Tapping: Are We Inserting Pedicle Screws Correctly?

    PubMed

    Prasad, Vishal; Mesfin, Addisu; Lee, Robert; Reigrut, Julie; Schmidt, John

    2016-11-01

    Although there are a significant number of research publications on the topic of bone morphology and the strength of bone, the clinical significance of a failed pedicle screw is often revision surgery and the potential for further postoperative complications; especially in elderly patients with osteoporotic bone. The purpose of this report is to quantify the mechanical strength of the foam-screw interface by assessing probe/pilot hole diameter and tap sizes using statistically relevant sample sizes under highly controlled test conditions. The study consisted of two experiments and used up to three different densities of reference-grade polyurethane foam (ASTM 1839), including 0.16, 0.24, and 0.32 g/cm 3 . All screws and rods were provided by K2M Inc. and screws were inserted to a depth of 25 mm. A series of pilot holes, 1.5, 2.2, 2.7, 3.2, 3.7, 4.2, 5.0, and 6.0 mm in diameter were drilled through the entire depth of the material. A 6.5 × 45-mm pedicle screw was inserted and axially pulled from the material (n = 720). A 3.0-mm pilot hole was drilled and tapped with: no tap, 3.5-, 4.5-, 5.5-, and 6.5-mm taps. A 6.5 × 45-mm pedicle screw was inserted and axially pulled from the material (n = 300). The size of the probe/pilot hole had a nonlinear, parabolic effect on pullout strength. This shape suggests an optimum-sized probe hole for a given size pedicle screw. Too large or too small of a probe hole causes a rapid falloff in pullout strength. The tap data demonstrated that not tapping and undertapping by two or three sizes did not significantly alter the pullout strength of the screws. The data showed an exponential falloff of pullout strength when as tap size increased to the diameter of the screw. In the current study, the data show that an ideal pilot hole size half the diameter of the screw is a starting point. Also, that if tapping was necessary, to use a tap two sizes smaller than the screw being implanted. A similar optimum pilot hole or tap size may be expected in the clinical scenario, however, it may not be the same as seen with the uniform density polyurethane foam tested in the current study. Copyright © 2016 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  9. Microbial environmental contamination in Italian dental clinics: A multicenter study yielding recommendations for standardized sampling methods and threshold values.

    PubMed

    Pasquarella, Cesira; Veronesi, Licia; Napoli, Christian; Castiglia, Paolo; Liguori, Giorgio; Rizzetto, Rolando; Torre, Ida; Righi, Elena; Farruggia, Patrizia; Tesauro, Marina; Torregrossa, Maria V; Montagna, Maria T; Colucci, Maria E; Gallè, Francesca; Masia, Maria D; Strohmenger, Laura; Bergomi, Margherita; Tinteri, Carola; Panico, Manuela; Pennino, Francesca; Cannova, Lucia; Tanzi, Marialuisa

    2012-03-15

    A microbiological environmental investigation was carried out in ten dental clinics in Italy. Microbial contamination of water, air and surfaces was assessed in each clinic during the five working days, for one week per month, for a three-month period. Water and surfaces were sampled before and after clinical activity; air was sampled before, after, and during clinical activity. A wide variation was found in microbial environmental contamination, both within the participating clinics and for the different sampling times. Before clinical activity, microbial water contamination in tap water reached 51,200cfu/mL (colony forming units per milliliter), and that in Dental Unit Water Systems (DUWSs) reached 872,000cfu/mL. After clinical activity, there was a significant decrease in the Total Viable Count (TVC) in tap water and in DUWSs. Pseudomonas aeruginosa was found in 2.38% (7/294) of tap water samples and in 20.06% (59/294) of DUWS samples; Legionella spp. was found in 29.96% (89/297) of tap water samples and 15.82% (47/297) of DUWS samples, with no significant difference between pre- and post-clinical activity. Microbial air contamination was highest during dental treatments, and decreased significantly at the end of the working activity (p<0.05). The microbial buildup on surfaces increased significantly during the working hours. This study provides data for the establishment of standardized sampling methods, and threshold values for contamination monitoring in dentistry. Some very critical situations have been observed which require urgent intervention. Furthermore, the study emphasizes the need for research aimed at defining effective managing strategies for dental clinics. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Commercializing Defense Technologies and Helping Defense Firms Succeed in Commercial Markets: A Report on the Objectives, Activities, and Accomplishments of the TAP-IN Program

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Technology Access for Product Innovation (TAP-IN), the largest technology deployment project funded by TRP, was competitively selected through a national solicitation for proposals. TAP-IN was created to help companies access and apply defense technologies and help defense-dependent companies enter new commercial markets. Defense technologies included technologies developed by DoD, DOE, NASA, and their contractors. TAP-IN was structured to provide region-based technology access services that were able to draw on technology resources nationwide. TAP-IN provided expert assistance in all stages of the commercialization process from concept through prototype design to capital sourcing and marketing strategy. TAP-IN helped companies locate new technology, identify business partners, secure financing, develop ideas for new products, identify new markets, license technology, solve technical problems, and develop company-specific applications of federal technology. TAP-IN leveraged NASA's existing commercial technology network to create an integrated national network of organizations that assisted companies in every state. In addition to NASA's six regional technology transfer centers (RTTCs), TAP-IN included business and technology development organizations in every state, the Industrial Designers Society of America, and the Federal Laboratory Consortium (FLC).

  11. Detection of Escherichia coli, Salmonella species, and Vibrio cholerae in tap water and bottled drinking water in Isfahan, Iran.

    PubMed

    Momtaz, Hassan; Dehkordi, Farhad Safarpoor; Rahimi, Ebrahim; Asgarifar, Amin

    2013-06-07

    The quality of drinking water has an important role in human infection and disease. This study was aimed at comparing polymerase chain reaction and culture in detecting Escherichia coli, Salmonella species and Vibrio cholera in tape water and bottled drinking water in various seasons in Isfahan province, Iran. A total of 448 water samples from tap water and bottled mineral water were taken over 6 months, from July 2010 to December 2010, and after filtration, samples were examined by culture and polymerase chain reaction methods for detection of Escherichia coli, Salmonella species, and Vibrio cholerae. The culture method showed that 34 (7.58%), 4 (0.89%) and 3 (0.66%) of all 448 water samples were positive for Escherichia coli, Salmonella species, and Vibrio cholera, respectively. The uidA gene from Escherichia coli, IpaB gene from Salmonella species, and epsM gene from Vibrio cholera were detected in 38 (26.38%), 5 (3.47%), and 3 (2.08%) of 144 tap-water samples, respectively. Escherichia coli was detected in 8 (2.63%) of 304 samples of bottled drinking water from 5 companies. The water of southern part of Isfahan and company 5 had the highest prevalence of bacteria. The Escherichia coli water contamination was significantly higher (P < 0.05) in the hot seasons (July-August) than cold (November-December) seasons and in company 5 than other companies. There were significant differences (P < 0.05) for the prevalence of bacteria between the tap waters of southern part and tap waters of central part of Isfahan. This study showed that the polymerase chain reaction assays can be an extremely accurate, fast, safe, sensitive and specific approach to monitor drinking water quality from purification facilities and bottled water companies. Also, our study confirmed the presence of Escherichia coli, Salmonella species, and Vibrio cholerae as water-borne pathogens in tap water and bottled drinking water of Isfahan, Iran. The present study showed the important public health problem in Isfahan, Iran.

  12. Detection of Escherichia coli, Salmonella species, and Vibrio cholerae in tap water and bottled drinking water in Isfahan, Iran

    PubMed Central

    2013-01-01

    Background The quality of drinking water has an important role in human infection and disease. This study was aimed at comparing polymerase chain reaction and culture in detecting Escherichia coli, Salmonella species and Vibrio cholera in tape water and bottled drinking water in various seasons in Isfahan province, Iran. Methods A total of 448 water samples from tap water and bottled mineral water were taken over 6 months, from July 2010 to December 2010, and after filtration, samples were examined by culture and polymerase chain reaction methods for detection of Escherichia coli, Salmonella species, and Vibrio cholerae. Results The culture method showed that 34 (7.58%), 4 (0.89%) and 3 (0.66%) of all 448 water samples were positive for Escherichia coli, Salmonella species, and Vibrio cholera, respectively. The uidA gene from Escherichia coli, IpaB gene from Salmonella species, and epsM gene from Vibrio cholera were detected in 38 (26.38%), 5 (3.47%), and 3 (2.08%) of 144 tap-water samples, respectively. Escherichia coli was detected in 8 (2.63%) of 304 samples of bottled drinking water from 5 companies. The water of southern part of Isfahan and company 5 had the highest prevalence of bacteria. The Escherichia coli water contamination was significantly higher (P < 0.05) in the hot seasons (July-August) than cold (November-December) seasons and in company 5 than other companies. There were significant differences (P < 0.05) for the prevalence of bacteria between the tap waters of southern part and tap waters of central part of Isfahan. Conclusions This study showed that the polymerase chain reaction assays can be an extremely accurate, fast, safe, sensitive and specific approach to monitor drinking water quality from purification facilities and bottled water companies. Also, our study confirmed the presence of Escherichia coli, Salmonella species, and Vibrio cholerae as water-borne pathogens in tap water and bottled drinking water of Isfahan, Iran. The present study showed the important public health problem in Isfahan, Iran. PMID:23742181

  13. Growth of finiteness in the third year of life: replication and predictive validity.

    PubMed

    Hadley, Pamela A; Rispoli, Matthew; Holt, Janet K; Fitzgerald, Colleen; Bahnsen, Alison

    2014-06-01

    The authors of this study investigated the validity of tense and agreement productivity (TAP) scoring in diverse sentence frames obtained during conversational language sampling as an alternative measure of finiteness for use with young children. Longitudinal language samples were used to model TAP growth from 21 to 30 months of age for 37 typically developing toddlers. Empirical Bayes (EB) linear and quadratic growth coefficients and child sex were then used to predict elicited grammar composite scores on the Test of Early Grammatical Impairment (TEGI; Rice & Wexler, 2001) at 36 months. A random-effects quadratic model with no intercept best characterized TAP growth, replicating the findings of Rispoli, Hadley, and Holt (2009). The combined regression model was significant, with the 3 variables accounting for 55.5% of the variance in the TEGI composite scores. These findings establish TAP growth as a valid metric of finiteness in the 3rd year of life. Developmental and theoretical implications are discussed.

  14. Use of an Electronic Tongue System and Fuzzy Logic to Analyze Water Samples

    NASA Astrophysics Data System (ADS)

    Braga, Guilherme S.; Paterno, Leonardo G.; Fonseca, Fernando J.

    2009-05-01

    An electronic tongue (ET) system incorporating 8 chemical sensors was used in combination with two pattern recognition tools, namely principal component analysis (PCA) and Fuzzy logic for discriminating/classification of water samples from different sources (tap, distilled and three brands of mineral water). The Fuzzy program exhibited a higher accuracy than the PCA and allowed the ET to classify correctly 4 in 5 types of water. Exception was made for one brand of mineral water which was sometimes misclassified as tap water. On the other hand, the PCA grouped water samples in three clusters, one with the distilled water; a second with tap water and one brand of mineral water, and the third with the other two other brands of mineral water. Samples in the second and third clusters could not be distinguished. Nevertheless, close grouping between repeated tests indicated that the ET system response is reproducible. The potential use of the Fuzzy logic as the data processing tool in combination with an electronic tongue system is discussed.

  15. Determination of uranium in tap water by ICP-MS.

    PubMed

    El Himri, M; Pastor, A; de la Guardia, M

    2000-05-01

    A fast and accurate procedure has been developed for the determination of uranium at microg L(-1) level in tap and mineral water. The method is based on the direct introduction of samples, without any chemical pre-treatment, into an inductively coupled plasma mass spectrometer (ICP-MS). Uranium was determined at the mass number 238 using Rh as internal standard. The method provides a limit of detection of 2 ng L(-1) and a good repeatability with relative standard deviation values (RSD) about 3% for five independent analyses of samples containing 73 microg L(-1) of uranium. Recovery percentage values found for the determination of uranium in spiked natural samples varied between 91% and 106%. Results obtained are comparable with those found by radiochemical methods for natural samples and of the same order for the certified content of a reference material, thus indicating the accuracy of the ICP-MS procedure without the need of using isotope dilution. A series of mineral and tap waters from different parts of Spain and Morocco were analysed.

  16. Transversus abdominal plane (TAP) block for postoperative pain management: a review.

    PubMed

    Jakobsson, Jan; Wickerts, Liselott; Forsberg, Sune; Ledin, Gustaf

    2015-01-01

    Transversus abdominal plane (TAP) block has a long history and there is currently extensive clinical experience around TAP blocks. The aim of this review is to provide a summary of the present evidence on the effects of TAP block and to provide suggestions for further studies. There are several approaches to performing abdominal wall blocks, with the rapid implementation of ultrasound-guided technique facilitating a major difference in TAP block performance. During surgery, an abdominal wall block may also be applied by the surgeon from inside the abdominal cavity. Today, there are more than 11 meta-analyses providing a compiled evidence base around the effects of TAP block. These analyses include different procedures, different techniques of TAP block administration and, importantly, they compare the TAP block with a variety of alternative analgesic regimes. The effects of TAP block during laparoscopic cholecystectomy seem to be equivalent to local infiltration analgesia and also seem to be beneficial during laparoscopic colon resection. The effects of TAP are more pronounced when it is provided prior to surgery and these effects are local anaesthesia dose-dependent. TAP block seems an interesting alternative in patients with, for example, severe obesity where epidural or spinal anaesthesia/analgesia is technically difficult and/or poses a risk. There is an obvious need for further high-quality studies comparing TAP block prior to surgery with local infiltration analgesia, single-shot spinal analgesia, and epidural analgesia. These studies should be procedure-specific and the effects should be evaluated, both regarding short-term pain and analgesic requirement and also including the effects on postoperative nausea and vomiting, recovery of bowel function, ambulation, discharge, and protracted recovery outcomes (assessed by e.g., postoperative quality of recovery scale).

  17. Microbial quality and molecular identification of cultivable microorganisms isolated from an urban drinking water distribution system (Limassol, Cyprus).

    PubMed

    Botsaris, George; Kanetis, Loukas; Slaný, Michal; Parpouna, Christiana; Makris, Konstantinos C

    2015-12-01

    Microorganisms can survive and multiply in aged urban drinking water distribution systems, leading to potential health risks. The objective of this work was to investigate the microbial quality of tap water and molecularly identify its predominant cultivable microorganisms. Tap water samples collected from 24 different households scattered in the urban area of Limassol, Cyprus, were microbiologically tested following standard protocols for coliforms, E. coli, Pseudomonas spp., Enterococcus spp., and total viable count at 22 and 37 °C. Molecular identification was performed on isolated predominant single colonies using 16SrRNA sequencing. Approximately 85% of the household water samples were contaminated with one or more microorganisms belonging to the genera of Pseudomonas, Corynebacterium, Agrobacterium, Staphylococcus, Bacillus, Delftia, Acinetobacter, Enterococcus, Enterobacter, and Aeromonas. However, all samples tested were free from E. coli. This is the first report in Cyprus molecularly confirming specific genera of relevant microbial communities in tap water.

  18. Factors of the Psychopathic Personality Inventory: Criterion-Related Validity and Relationship to the BIS/BAS and Five-Factor Models of Personality

    ERIC Educational Resources Information Center

    Ross, Scott R.; Benning, Stephen D.; Patrick, Christopher J.; Thompson, Angela; Thurston, Amanda

    2009-01-01

    Psychopathy is a personality disorder that includes interpersonal-affective and antisocial deviance features. The Psychopathic Personality Inventory (PPI) contains two underlying factors (fearless dominance and impulsive antisociality) that may differentially tap these two sets of features. In a mixed-gender sample of undergraduates and prisoners,…

  19. Occurrence and sources of bromate in chlorinated tap drinking water in Metropolitan Manila, Philippines.

    PubMed

    Genuino, Homer C; Espino, Maria Pythias B

    2012-04-01

    Significant levels of potentially carcinogenic bromate were measured in chlorinated tap drinking water in Metropolitan Manila, Philippines, using an optimized ion-chromatographic method. This method can quantify bromate in water down to 4.5 μg l⁻¹ by employing a postcolumn reaction with acidic fuchsin and subsequent spectrophotometric detection. The concentration of bromate in tap drinking water samples collected from 21 locations in cities and municipalities within the 9-month study period ranged from 7 to 138 μg l⁻¹. The average bromate concentration of all tap drinking water samples was 66 μg l⁻¹ (n = 567), almost seven times greater than the current regulatory limit in the country. The levels of bromate in other water types were also determined to identify the sources of bromate found in the distribution lines and to further uncover contaminated sites. The concentration of bromate in water sourced from two rivers and two water treatment plants ranged from 15 to 80 and 12 to 101 μg l⁻¹, respectively. Rainwater did not contribute bromate in rivers but decreased bromate level by dilution. Groundwater and wastewater samples showed bromate concentrations as high as 246 and 342 μg l⁻¹, respectively. Bromate presence in tap drinking water can be linked to pollution in natural water bodies and the practice of using hypochlorite chemicals in addition to gaseous chlorine for water disinfection. This study established the levels, occurrence, and possible sources of bromate in local drinking water supplies.

  20. Boron exposure assessment using drinking water and urine in the North of Chile.

    PubMed

    Cortes, S; Reynaga-Delgado, E; Sancha, A M; Ferreccio, C

    2011-12-01

    Boron is an essential trace element for plants and humans however it is still an open question what levels of boron are actually safe for humans. This study, conducted between 2006 and 2010, measured exposure levels of boron in drinking water and urine of volunteers in Arica, an area in the North of Chile with high levels of naturally occurring boron. Samples were taken of tap and bottled water (173 and 22, respectively), as well as urine from 22 volunteers, and subsequently analyzed by inductively coupled plasma spectroscopy (ICP-OES). Boron varied in public tap water from 0.22 to 11.3mgL(-1), with a median value of 2.9mgL(-1), while concentrations of boron in bottled water varied from 0.01 to 12.2mgL(-1). Neither tap nor bottled water samples had concentrations of boron within WHO recommended limits. The concentration of boron in urine varied between 0.45 and 17.4mgL(-1), with a median of 4.28mgL(-1) and was found to be correlated with tap water sampled from the homes of the volunteers (r=0.64). Authors highly recommend that in northern Chile - where levels of boron are naturally high - that the tap and bottled water supplies be monitored in order to protect public health and that regulatory standards also be established for boron in drinking water in order to limit exposure. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Gestalt Therapy: Student Perceptions of Fritz Perls in "Three Approaches to Psychotherapy"

    ERIC Educational Resources Information Center

    Reilly, Joe; Jacobus, Veronica

    2009-01-01

    The "Three Approaches to Psychotherapy" ("TAP") videotape series introduces students to three major schools of psychotherapy: client-centered therapy, Gestalt therapy, and rational-emotive therapy. A sample of undergraduate students viewed the "TAP" series. The students were surveyed about their observations of…

  2. Identification and description of potential ground-water quality monitoring wells in Florida

    USGS Publications Warehouse

    Seaber, P.R.; Thagard, M.E.

    1986-01-01

    The results of a survey of existing wells in Florida that meet the following criteria are presented: (1) well location is known , (2) principal aquifer is known, (3) depth of well is known, (4) well casing depth is known, (5) well water had been analyzed between 1970 and 1982, and (6) well data are stored in the U.S. Geological Survey 's (USGS) computer files. Information for more than 20,000 wells in Florida were stored in the USGS Master Water Data Index of the National Water Data Exchange and in the National Water Data Storage and Retrieval System 's Groundwater Site Inventory computerized files in 1982. Wells in these computer files that had been sampled for groundwater quality before November 1982 in Florida number 13,739; 1,846 of these wells met the above criteria and are the potential (or candidate) groundwater quality monitoring wells included in this report. The distribution by principal aquifer of the 1,846 wells identified as potential groundwater quality monitoring wells is as follows: 1,022 tap the Floridan aquifer system, 114 tap the intermediate aquifers, 232 tap the surficial aquifers, 246 tap the Biscayne aquifer, and 232 tap the sand-and-gravel aquifer. These wells are located in 59 of Florida 's 67 counties. This report presents the station descriptions, which include location , site characteristics, period of record, and the type and frequency of chemical water quality data collected for each well. The 1,846 well locations are plotted on 14 USGS 1:250,000 scale, 1 degree by 2 degree, quadrangle maps. This relatively large number of potential (or candidate) monitoring wells, geographically and geohydrologically dispersed, provides a basis for a future groundwater quality monitoring network and computerized data base for Florida. There is a large variety of water quality determinations available from these wells, both areally and temporally. Future sampling of these wells would permit analyses of time and areal trends for selected water quality characteristics throughout the State. The identification and description of the potential monitoring wells and the listing of the type and frequency of the groundwater quality data forms a foundation for both the network and the data base. (Author 's abstract)

  3. Simultaneous analysis of thiamphenicol and its prodrug thiamphenicol glycinate in human plasma and urine by high performance liquid chromatography: application to pharmacokinetic study.

    PubMed

    Chen, Xijing; Yang, Bing; Ni, Liang; Wang, Guangji

    2006-06-07

    A simple and sensitive method for simultaneous determination of the active compound, thiamphenicol (TAP) and its prodrug, thiamphenicol glycinate (TG) in human plasma and urine is described. The procedure involved extraction of TG and TAP with ethyl acetate (plasma) or 100-fold dilution with the mobile phase (urine) followed by determination by reversed-phase high performance liquid chromatography (HPLC) with UV detection at 224 nm. Separation of the compounds was achieved on a column packed with Hypersil ODS2. The mobile phase consisted of acetonitrile-water containing 0.003 M tetrabutyl ammonium bromide and 0.056 M ammonium acetate (87:13, v/v) with a flow rate of 1.0 ml/min. The chromatograms did not contain interfering peaks due to the suitable extraction procedure and chromatographic conditions. The calibration curves of TG and TAP were linear ranging from 0.78 to 100 microg/ml in plasma and in urine. The intra-day and inter-day relative standard deviations (S.D.) were less than 10%. The recoveries of TG and TAP in plasma and urine were above 80%. TG was not stable in plasma samples and after extraction at ambient temperature or in freeze-thaw cycles, and hence the samples for injection on HPLC column should be stored in refrigerator or under ice cooling prior to analysis, and the plasma samples should not experience the freeze-thaw cycle more than one time. Unlike TAP, TG could not be detected in most urine samples. Application of this method demonstrated that it was feasible for the clinical pharmacokinetic study.

  4. Ionic Liquid Dispersive Liquid-Liquid Microextraction Method for the Determination of Irinotecan, an Anticancer Drug, in Water and Urine Samples Using UV-Vis Spectrophotometry.

    PubMed

    Uysal, Deniz; Karadaş, Cennet; Kara, Derya

    2017-05-01

    A new, simple, efficient, and environmentally friendly ionic liquid dispersive liquid-liquid microextraction method was developed for the determination of irinotecan, an anticancer drug, in water and urine samples using UV-Vis spectrophotometry. The ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate was used as the extraction solvent, and ethanol was used as the disperser solvent. The main parameters affecting the extraction efficiency, including sample pH, volume of the ionic liquid, choice of the dispersive solvent and its volume, concentration of NaCl, and extraction and centrifugation times, were investigated and optimized. The effect of interfering species on the recovery of irinotecan was also examined. Under optimal conditions, the LOD (3σ) was 48.7 μg/L without any preconcentration. Because the urine sample was diluted 10-fold, the LOD for urine would be 487 μg/L. However, this could be improved 16-fold if preconcentration using a 40 mL aliquot of the sample is used. The proposed method was successfully applied to the determination of irinotecan in tap water, river water, and urine samples spiked with 10.20 mg/L for the water samples and 8.32 mg/L for the urine sample. The average recovery values of irinotecan determined were 99.1% for tap water, 109.4% for river water, and 96.1% for urine.

  5. Impact of effluents from a car battery manufacturing plant in Nigeria on water, soil, and food qualities.

    PubMed

    Orisakwe, Orish Ebere; Asomugha, Rose; Afonne, Onyenmechi Johnson; Anisi, C N; Obi, Ejeatuluchukwualo; Dioka, Chudi Emma

    2004-01-01

    The authors investigated the impact of effluents from a car battery manufacturing plant in Nnewi, Nigeria, on water, soil, and food qualities. The authors analyzed heavy metals mercury, arsenic, lead, cadmium and nickel in tap and cassava waters, soil, dried cassava tuber, and edible fruit samples from the company, using an atomic absorption spectrophotometer. Other parameters the authors analyzed include pH, electrical conductivity (EC), salinity (SAL), total hardness (TH), biological oxygen demand (BOD), volatile and non-volatile solids, and bacterial and fungal loads of the soil samples. Results show that lead had the highest concentration in all the samples, with the soil samples having the highest lead concentration (38-12 ppm, 102 ppm) and the water samples having the lowest (0.02-0.20 ppm). Mercury had the lowest concentration (<0.0002 ppm) in all the samples. Soil sample B had the highest concentration of all the metals tested. Cassava water had higher levels of EC, SAL, TH, BOD, and volatile and nonvolatile solids, but lower pH than tap water. Bacterial loads were higher than fungal loads in all the soil samples. Because there was moderate contamination of the environment by some of the metals studied, with lead being exceptionally high and above the specified international standards, the authors recommend control measures to reduce lead exposure to the local populace within and around this industry.

  6. NASA/UK TAP

    NASA Technical Reports Server (NTRS)

    1987-01-01

    The purpose of the Technology Applications Program (TAP) is to provide problem solving information and assistance to both the public and private sectors in the Commonwealth of Kentucky, with emphasis primarily in the public sector. The TAP accesses over 1200 online computer databases, including files from the U.S., Canada, Europe, and Australia. During the 1985 to 1986 contract period, TAP responded to 645 inquiries which resulted in an increase of 16 percent over the 1984 to 1985 contract period. The activities of TAP for the 1985 to 1986 contract period are summarized.

  7. Executive Function Skills of 6 to 8 Year Olds: Brain and Behavioral Evidence and Implications for School Achievement

    PubMed Central

    Molfese, Victoria J.; Molfese, Peter J.; Molfese, Dennis L.; Rudasill, Kathleen M.; Armstrong, Natalie; Starkey, Gillian

    2010-01-01

    Academic and social success in school has been linked to children’s self-regulation. This study investigated the assessment of the executive function (EF) component of self-regulation using a low-cost, easily administered measure to determine whether scores obtained from the behavioral task would agree with those obtained using a laboratory-based neuropsychological measure of EF skills. The sample included 74 children (37 females; M = 86.2 months) who participated in two assessments of working memory and inhibitory control: Knock-Tap (NEPSY: Korkman, Kirk, and Kemp, 1998), and participation in event-related potential (ERP) testing that included the Directional Stroop Test (Davidson, Cruess, Diamond, O’Craven, & Savoy, 1999). Three main findings emerged. First, children grouped as high versus low performing on the NEPSY Knock-Tap Task were found to performed differently on the more difficult conditions of the DST (the Incongruent and Mixed Conditions), suggesting that the Knock-Tap Task as a low-cost and easy to administer assessment of EF skills may be one way for teachers to identify students with poor inhibitory control skills. Second, children’s performance on the DST was strongly related to their ERP responses, adding to evidence that differences in behavioral performance on the DST as a measure of EF skills reflect corresponding differences in brain processing. Finally, differences in brain processing on the DST task also were found when the children were grouped based on Knock-Tap performance. Simple screening procedures can enable teachers to identify children whose distractibility, inattentiveness, or poor attention spans may interfere with classroom learning. PMID:20798857

  8. Mycobacterium chimaera in heater-cooler units used during cardiac surgery - growth and decontamination.

    PubMed

    Bengtsson, Daniel; Westerberg, Martin; Nielsen, Susanne; Ridell, Malin; Jönsson, Bodil

    2018-04-24

    Previous studies have identified patients infected with Mycobacterium chimaera (M. chimaera) subsequent to cardiac surgery. Water tanks in heater-cooler units (HCUs) used cardiac heart surgery was traced as source. The aim was to investigate occurrence of M. chimaera and other microorganisms in HCUs and evaluate the silver-ion cleaning routine. Five HCUs were disinfected with silver-ions and examined for mycobacteria directly (15 min) after the disinfection procedures and later on three occasions (3, 6, 10 weeks). One HCU was selected for additional investigation of the presence of other microorganisms. In addition, tap water from five sinks in the surgical department was examined for the presence of mycobacteria and other microorganisms. M. chimaera grew in all the HCU water tanks and in 35 of the 40 HCU samples. Three of the samples also contained Mycobacterium gordonae. When the selected HCU tanks were analysed directly after the disinfection procedure bacteria and fungi were found but no non-fermenting Gram-negative rods. These HCU samples contained a doubled to 3 fold amount of bacteria compared to initial tap water samples. No mycobacteria were found in any sample from the five water taps. The silver-ion cleaning routine was insufficient and M. chimaera was found in all HCUs. However, no mycobacteria were found in any sample from the five water taps suggesting another source of colonization. It is probable that residual water and biofilm are of importance. Our results emphasize the need for improved disinfection procedures and improved construction of the HCUs.

  9. Chemical quality of tap water in Madrid: multicase control cancer study in Spain (MCC-Spain).

    PubMed

    Fernández-Navarro, Pablo; Villanueva, Cristina M; García-Pérez, Javier; Boldo, Elena; Goñi-Irigoyen, Fernando; Ulibarrena, Enrique; Rantakokko, Panu; García-Esquinas, Esther; Pérez-Gómez, Beatriz; Pollán, Marina; Aragonés, Nuria

    2017-02-01

    Chronic consumption of water, which contains contaminants, may give rise to adverse health effects. The Madrid region, covered by the population-based multicase-control (MCC-Spain) study, includes two drinking water supply areas. The different sources of the water, coupled together with the possible differences in water management, mean that there may be differences in drinking water quality. In the context of the MCC study, our aims were to describe contaminant concentrations in tap water drawn from various sampling points distributed around the region, assess these concentrations by reference to guideline values and study possible differences between the two supply areas. Tap water samples were collected from 34 sampling points in 7 towns in the Madrid region (19-29 April 2010), and 23 contaminants (metals, nitrates, disinfection by-product and Mutagen X levels) were quantified. We undertook a descriptive analysis of the contaminant concentrations in the water and compared them between the two water supply areas (Wilcoxon test). We created maps representing the distribution of the concentrations observed at water sampling points and assessed the correlations (Spearman's coefficient) between the different parameters measured. The concentrations of the contaminants were below guideline values. There were differences between the two supply areas in concentration of nitrates (p value = 0.0051) and certain disinfection by-products. While there were positive correlations (rho >0.70) among some disinfection by-products, no correlations were found in metals or nitrates. The differences in nitrate levels could be linked to differences in farming/industrial activities in the catchment areas and in disinfection by-products might be related to the existence of different treatment systems or bromine content in source waters.

  10. Assessment of the Extraction Methods for Monitoring Phthalate Emerging Contaminants in Groundwater and Tap Water

    NASA Astrophysics Data System (ADS)

    Cotto, I.; Padilla, I. Y.; De Jesús, N. H.; Torres, P. M.

    2015-12-01

    Trace organic contaminants such as phthalates, among other chemicals of emerging concerns, have not historically been considered as pollutants but are being detected in water, posing a potential risk to public health and the environment. One of the most common phthalates of particular concern is di-(2-ethylhexyl) phthalate (DEHP), a plasticizer normally found in plastics and consumer products, including: cosmetics, pharmaceuticals, medical devices, food packages, water bottles, and wiring cables. DEHP has been associated with preterm birth, a major cause of neonatal mortality and health complications. This study aims at monitoring the presence and concentration of DEHP and other phthalates in groundwater and tap water systems in Puerto Rico, which has one of the highest rates of preterm birth in the U.S. The Environmental Protection Agency (EPA) suggests a liquid-liquid extraction method that uses methylene chloride as the preferred organic solvent for the extractions. This work presents modified EPA methods that reduce the volume of sample and solvent used, lower the time of analysis, increase productivity, and decrease hazards and waste. Distribution coefficient of DEHP between methylene chloride and water are estimated and related to sample extraction efficiency. Research results indicate that DEHP is in fact distributed between water and methylene chloride with a distribution coefficient average value of 1.24. The study concludes that the sample and solvent volumes have influence on the efficiency but have not an effect on the distribution coefficient. The tests show higher extraction efficiencies for lower DEHP concentrations and higher extraction volumes. Results from the water analysis show presence of DEHP in 55% of groundwater and 44% of tap water samples, indicating a potential exposure through water.

  11. Spatial, seasonal, and source variability in the stable oxygen and hydrogen isotopic composition of tap waters throughout the USA

    USGS Publications Warehouse

    Landwehr, Jurate M.; Coplen, Tyler B.; Stewart, David W.

    2013-01-01

    To assess spatial, seasonal, and source variability in stable isotopic composition of human drinking waters throughout the entire USA, we have constructed a database of δ18O and δ2H of US tap waters. An additional purpose was to create a publicly available dataset useful for evaluating the forensic applicability of these isotopes for human tissue source geolocation. Samples were obtained at 349 sites, from diverse population centres, grouped by surface hydrologic units for regional comparisons. Samples were taken concurrently during two contrasting seasons, summer and winter. Source supply (surface, groundwater, mixed, and cistern) and system (public and private) types were noted. The isotopic composition of tap waters exhibits large spatial and regional variation within each season as well as significant at-site differences between seasons at many locations, consistent with patterns found in environmental (river and precipitation) waters deriving from hydrologic processes influenced by geographic factors. However, anthropogenic factors, such as the population of a tap’s surrounding community and local availability from diverse sources, also influence the isotopic composition of tap waters. Even within a locale as small as a single metropolitan area, tap waters with greatly differing isotopic compositions can be found, so that tap water within a region may not exhibit the spatial or temporal coherence predicted for environmental water. Such heterogeneities can be confounding factors when attempting forensic inference of source water location, and they underscore the necessity of measurements, not just predictions, with which to characterize the isotopic composition of regional tap waters. Published 2013. This article is a U.S. Government work and is in the public domain in the USA.

  12. Control system for a wound-rotor motor

    DOEpatents

    Ellis, James N.

    1983-01-01

    A load switching circuit for switching two or more transformer taps under load carrying conditions includes first and second parallel connected bridge rectifier circuits which control the selective connection of a direct current load to taps of a transformer. The first bridge circuit is normally conducting so that the load is connected to a first tap through the first bridge circuit. To transfer the load to the second tap, a switch is operable to connect the second bridge circuit to a second tap, and when the second bridge circuit begins to conduct, the first bridge circuit ceases conduction because the potential at the second tap is higher than the potential at the first tap, and the load is thus connected to the second tap through the second bridge circuit. The load switching circuit is applicable in a motor speed controller for a wound-rotor motor for effecting tap switching as a function of motor speed while providing a stepless motor speed control characteristic.

  13. Placental share and hemoglobin level in relation to birth weight in twin anemia-polycythemia sequence.

    PubMed

    Zhao, D; Slaghekke, F; Middeldorp, J M; Duan, T; Oepkes, D; Lopriore, E

    2014-12-01

    Twin anemia-polycythemia sequence (TAPS) is a newly described form of chronic twin transfusion. Previous observational studies noted a discordance between birth weight and individual placental share in TAPS. The purpose of this study was to investigate if fetal growth in monochorionic (MC) twins with TAPS is determined by placental share or by the net inter-twin blood transfusion. All consecutive MC twin placentas of live-born twin pairs with and without TAPS examined at our center between June 2002 and February 2014 were included in this study. Hemoglobin (Hb) levels and individual placental share were evaluated at birth and correlated with birth weight share. We excluded MC twin pregnancies with twin-twin transfusion syndrome. A total of 270 MC twin pregnancies (TAPS group, n = 20; control group without TAPS, n = 250) were included in this study. Donors with TAPS had a lower birth weight than recipients in 90% (18/20) of cases, but a larger placental share in 65% (13/20) of cases. In the TAPS group, birth weight share was positively correlated with Hb share at birth (P < 0.01) but not with placental share (P = 0.54). In the control group without TAPS, birth weight share was strongly correlated with placental share (P < 0.01) but not with Hb share (P = 0.14). A relatively larger placental share may enable the survival of the anemic twin in TAPS. In contrast with uncomplicated MC twins, fetal growth in MC twins with TAPS is determined primarily by the net inter-twin blood transfusion instead of placental share. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Occurrence of thyroid hormone activities in drinking water from eastern China: contributions of phthalate esters.

    PubMed

    Shi, Wei; Hu, Xinxin; Zhang, Fengxian; Hu, Guanjiu; Hao, Yingqun; Zhang, Xiaowei; Liu, Hongling; Wei, Si; Wang, Xinru; Giesy, John P; Yu, Hongxia

    2012-02-07

    Thyroid hormone is essential for the development of humans. However, some synthetic chemicals with thyroid disrupting potentials are detectable in drinking water. This study investigated the presence of thyroid active chemicals and their toxicity potential in drinking water from five cities in eastern China by use of an in vitro CV-1 cell-based reporter gene assay. Waters were examined from several phases of drinking water processing, including source water, finished water from waterworks, tap water, and boiled tap water. To identify the responsible compounds, concentrations and toxic equivalents of a list of phthalate esters were quantitatively determined. None of the extracts exhibited thyroid receptor (TR) agonist activity. Most of the water samples exhibited TR antagonistic activities. None of the boiled water displayed the TR antagonistic activity. Dibutyl phthalate accounted for 84.0-98.1% of the antagonist equivalents in water sources, while diisobutyl phthalate, di-n-octyl phthalate and di-2-ethylhexyl phthalate also contributed. Approximately 90% of phthalate esters and TR antagonistic activities were removable by waterworks treatment processes, including filtration, coagulation, aerobic biodegradation, chlorination, and ozonation. Boiling water effectively removed phthalate esters from tap water. Thus, this process was recommended to local residents to reduce certain potential thyroid related risks through drinking water.

  15. Fluoride and bacterial content of bottled drinking water versus municipal tap water.

    PubMed

    Mythri, H; Chandu, G N; Prashant, G M; Subba Reddy, V V

    2010-01-01

    Water is a divine gift. People quench their thirst without questioning the source of water. But, apprehension about contaminants in municipal water supplies along with increased fear of fluorosis made bottled drinking water as one of the important tradable commodities. The objectives of the study were to determine and compare the fluoride and bacterial contents of commercially available bottled drinking water and municipal tap water in Davangere city, Karnataka. Fifty samples of 10 categories of bottled drinking water with different batch numbers were purchased and municipal water from different sources were collected. Fluoride levels were determined by an ion-selective electrode. Water was cultured quantitatively and levels of bacteria were calculated as colony-forming units (CFUs) per milliliter. Descriptive analysis of water samples for fluoride concentration was in the range of 0.07-0.33 for bottled drinking water, Bisleri showing the highest of 0.33. A comparison of the mean values of microbial count for bottled drinking water with that of municipal tap water showed no statistically significant difference, but was more than the standard levels along with the presence of fungus and maggots. The fluoride concentration was below the optimal level for both municipal tap water and bottled drinking water. CFUs were more than the recommended level in both municipal tap water and bottled drinking water.

  16. Drugs of abuse, cytostatic drugs and iodinated contrast media in tap water from the Madrid region (central Spain):A case study to analyse their occurrence and human health risk characterization.

    PubMed

    Mendoza, A; Zonja, B; Mastroianni, N; Negreira, N; López de Alda, M; Pérez, S; Barceló, D; Gil, A; Valcárcel, Y

    2016-01-01

    This work analyses the presence of forty-eight emerging pollutants, including twenty-five drugs of abuse and metabolites, seventeen cytostatic drugs and six iodinated contrast media, in tap water from the Madrid Region. Analysis of the target compounds in the tap water was performed by means of (on-line or off-line) solid-phase extraction followed by analysis by liquid chromatography-tandem mass spectrometry. A preliminary human health risk characterization was undertaken for each individual compound and for different groups of compounds with a common mechanism of action found in tap water. The results of the study showed the presence of eight out of the twenty-five drugs of abuse and metabolites analysed, namely, the cocainics cocaine and benzoylecgonine, the amphetamine-type stimulants ephedrine, 3,4-methylenedioxymethamphetamine and methamphetamine, the opioid methadone and its metabolite 2-ethylene-1,5-dimethyl-3,3-diphenylpyrrolidine and, finally caffeine at concentrations ranging from 0.11 to 502 ng L(-1). Four out of the six analysed iodinated contrast media, namely, diatrizoate, iohexol, iomeprol and iopromide, were detected in at least one sample, with concentration values varying between 0.4 and 5 ng L(-1). Cytostatic compounds were not detected in any sample. Caffeine was the substance showing the highest concentrations, up to 502 ng L(-1), mainly in the drinking water sampling point located in Madrid city. Among the other drugs of abuse, the most abundant compounds were cocaine and benzoylecgonine, detected at concentrations ranging from 0.11 to 86 ng L(-1) and from 0.11 to 53 ng L(-1), respectively. Regarding iodinated contrast media, iohexol was the most ubiquitous and abundant compound, with a frequency of detection of 100% and concentrations from 0.5 to 5.0 ng L(-1) in basically the same range in all sampling points. Taking into account the results and types of treatment applied, ozonisation plus granular activated carbon filtration appears to be efficient in the removal of cocaine and benzoylecgonine. For the amphetamine-type stimulants, opioids and caffeine, ozonisation plus granular activated carbon filtration and ultrafiltration plus reverse osmosis showed higher removal efficiency than sand filtration. The human health risk characterization performed indicates that the lifetime consumption of the tap waters analysed has associated a negligible human health concern. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Filtration of water-sediment samples for the determination of organic compounds

    USGS Publications Warehouse

    Sandstrom, Mark W.

    1995-01-01

    This report describes the equipment and procedures used for on-site filtration of surface-water and ground-water samples for determination of organic compounds. Glass-fiber filters and a positive displacement pumping system are suitable for processing most samples for organic analyses. An optional system that uses disposable in-line membrane filters is suitable for a specific gas chromatography/mass spectrometry, selected-ion monitoring analytical method for determination of organonitrogen herbicides. General procedures to minimize contamination of the samples include preparing a clean workspace at the site, selecting appropriate sample-collection materials, and cleaning of the equipment with detergent, tap water, and methanol.

  18. [The toxicity variation of organic extracts in drinking water treatment processes].

    PubMed

    Mei, M; Wei, S; Zijian, W; Wenhua, W; Baohua, Z; Suxia, Z

    2001-01-01

    Source water samples and outlet water samples from different treatment processes of the Beijing Ninth Water Works were concentrated in situ with XAD-2 filled columns. GC-MS analysis and toxic assessment including acute toxicity evaluation by luminescent bacterium bioassay(Q67 strains) and mutagenicity assessment by Ames test(TA98 and TA100 strains with and without S9 addition) were conducted on these samples. The results showed that prechlorination caused the direct and indirect frame shift mutagenicity as well as indirect base pair substitute mutagenicity. Addition of coagulant may increase the base pair substitute mutagenic effects greatly. Sand and coal filtration and granular activated carbon filtration could effectively remove most of the formed mutagens. The rechlorination do not obviously increase the mutagenic effects. No mutagenic effect was observed in tap water. Acute toxicity showed the same variation with that of mutagenicity during the treatment processes. Sample from flocculation treatment process was found to be the most toxic sample. Results of GC-MS analysis showed that water in this plant was not contaminated by PCB. Concentrations of toluene, naphthalene and phenol increased in flocculation treatment process and in tap water. However, the concentrations of these substances were at the level of microgram/L, therefore, were not high enough to cause mutagenicity.

  19. Quantifying tap-to-household water quality deterioration in urban communities in Vellore, India: The impact of spatial assumptions.

    PubMed

    Alarcon Falconi, Tania M; Kulinkina, Alexandra V; Mohan, Venkata Raghava; Francis, Mark R; Kattula, Deepthi; Sarkar, Rajiv; Ward, Honorine; Kang, Gagandeep; Balraj, Vinohar; Naumova, Elena N

    2017-01-01

    Municipal water sources in India have been found to be highly contaminated, with further water quality deterioration occurring during household storage. Quantifying water quality deterioration requires knowledge about the exact source tap and length of water storage at the household, which is not usually known. This study presents a methodology to link source and household stored water, and explores the effects of spatial assumptions on the association between tap-to-household water quality deterioration and enteric infections in two semi-urban slums of Vellore, India. To determine a possible water source for each household sample, we paired household and tap samples collected on the same day using three spatial approaches implemented in GIS: minimum Euclidean distance; minimum network distance; and inverse network-distance weighted average. Logistic and Poisson regression models were used to determine associations between water quality deterioration and household-level characteristics, and between diarrheal cases and water quality deterioration. On average, 60% of households had higher fecal coliform concentrations in household samples than at source taps. Only the weighted average approach detected a higher risk of water quality deterioration for households that do not purify water and that have animals in the home (RR=1.50 [1.03, 2.18], p=0.033); and showed that households with water quality deterioration were more likely to report diarrheal cases (OR=3.08 [1.21, 8.18], p=0.02). Studies to assess contamination between source and household are rare due to methodological challenges and high costs associated with collecting paired samples. Our study demonstrated it is possible to derive useful spatial links between samples post hoc; and that the pairing approach affects the conclusions related to associations between enteric infections and water quality deterioration. Copyright © 2016 Elsevier GmbH. All rights reserved.

  20. 40 CFR 63.11528 - What are the performance test and compliance requirements for new and existing sources?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 CFR part 60). The test must be conducted for at least 60 minutes and shall include tapping the... of the readings over the furnace cycle (tap to tap) or 60 minutes, whichever is longer. If VE are...

  1. Analysis of perfluoroalkyl substances in waters from Germany and Spain.

    PubMed

    Llorca, Marta; Farré, Marinella; Picó, Yolanda; Müller, Jutta; Knepper, Thomas P; Barceló, Damià

    2012-08-01

    Water has been identified as one of the main routes of human exposure to perfluoroalkyl substances (PFASs). This work assessed the presence of 21 PFASs along the whole water cycle using a new fast and cost effective analytical method based on an online sample enrichment followed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The method was validated for different types of matrices (ultrapure water, tap water and treated wastewater). The quality parameters for the 21 selected compounds presented good limits of detection (LOD) and quantification (LOQ) ranging, in general, from 0.83-10 ng/L to 2.8-50 ng/L, respectively. The method was applied to assess the occurrence of PFASs in 148 water samples of different steps along the whole water cycle, including: mineral bottled water, tap water, river water and treated effluent wastewater, from Germany to Spain. In addition, in order to prove the good performance of the online analytical method, the analysis of PFASs was carried out in parallel using a method based on offline anionic solid phase extraction (SPE) followed by LC-MS/MS. Consistent results were obtained using both approaches. The more frequently found compounds were perfluoroalkyl acids, such as the perfluorobutanoic acid which was in the 54% of the tap water samples investigated with concentrations in the range between 2.4 and 27 ng/L, the perfluoroheptanoic acid (0.23-53 ng/L) and perfluorooctanoic acid (0.16-35 ng/L), and the sulphonate perfluorooctanesulfonate (0.04-258 ng/L) which was the second more frequent compound and also the compound found in with the higher concentration. It should be remarked that the 88% of the samples analyzed presented at least one of the compounds at quantifiable concentrations. In addition, PFASs including short chain compounds were proved to be prevalent in drinking water, and the 50% of the drinking water samples showed quantifiable concentrations of PFASs. It should be said that the great majority of the samples may not pose an immediate health risk to consumers, and just 6 of the drinking water samples presented concentrations of PFOS exceeding the Provisional Health Advisory (PHA) level established by the Office of Water from the USEPA for PFOS, which was set in 200 ng/L. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Generic framework for the secure Yuen 2000 quantum-encryption protocol employing the wire-tap channel approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mihaljevic, Miodrag J.

    2007-05-15

    It is shown that the security, against known-plaintext attacks, of the Yuen 2000 (Y00) quantum-encryption protocol can be considered via the wire-tap channel model assuming that the heterodyne measurement yields the sample for security evaluation. Employing the results reported on the wire-tap channel, a generic framework is proposed for developing secure Y00 instantiations. The proposed framework employs a dedicated encoding which together with inherent quantum noise at the attacker's side provides Y00 security.

  3. Analgesic Effect Of Bilateral Subcostal Tap Block After Laparoscopic Cholecystectomy.

    PubMed

    Khan, Karima Karam; Khan, Robyna Irshad

    2018-01-01

    Pain after laparoscopic cholecystectomy is mild to moderate in intensity. Several modalities are employed for achieving safe and effective postoperative analgesia, the benefits of which adds to the early recovery of the patients. As a part of multimodal analgesia, various approaches of Transversus abdominis plane (TAP) block has been used for management of parietal and incisional components of pain after laparoscopic cholecystectomy. This study was designed to compare the analgesic efficacy of two different approaches of ultrasound guided TAP block, i.e., Subcostal-TAP block technique with ultrasound guided Posterior-TAP block for postoperative pain management in patients undergoing laparoscopic cholecystectomy under general anaesthesia. In this double blinded randomized controlled study, consecutive nonprobability sampling was done and a total of 126 patients admitted for elective laparoscopic cholecystectomy fulfilling the inclusion criteria were selected. After induction of general anaesthesia, patients were randomized through draw method and received either ultrasound guided posterior TAP block with 0.375% bupivacaine (20ml volume) on each side of the abdomen or subcostal TAP block bilaterally with the same. Up to 24 hours postoperatively, static and dynamic numeric rating pain scores were assessed. We found statistically significant difference in mean static pain scores over 24 hours postoperatively in subcostal TAP group, suggesting improved analgesia. However, mean dynamic postoperative pain scores were comparable between the two groups. Whereas, patients in both groups were satisfied with pain management. Ultrasound guided subcostal TAP block provides better postoperative analgesia as compared to the Posterior TAP block in laparoscopic cholecystectomy. Otherwise both of the approaches improve patient outcomes towards early recovery and discharge from hospital.

  4. Changes in mouse gut bacterial community in response to different types of drinking water.

    PubMed

    Dias, Marcela F; Reis, Mariana P; Acurcio, Leonardo B; Carmo, Anderson O; Diamantino, Cristiane F; Motta, Amanda M; Kalapothakis, Evanguedes; Nicoli, Jacques R; Nascimento, Andréa M A

    2018-04-01

    Gut microbiota exerts a fundamental role on host physiology, and how extrinsic perturbations influence its composition has been increasingly examined. However, the effect of drinking water on gut microbiota is still poorly understood. In this study, we explored the response of mouse gut bacterial community (fecal and mucosa-adhered) to the ingestion of different types of drinking water. The experimental cohort was divided according to different water sources into four groups of mice that consumed autoclaved tap water (control group), water collected directly from a drinking water treatment plant, tap water, and commercial bottled mineral water. Differences among groups were observed, especially related to control group, which exhibited the smallest intra-group variation, and the largest distance from test groups on the last experimental day. Clinically important taxa, such as Acinetobacter and Staphylococcus, increased in feces of mice that drank tap water and in mucosa-adhered samples of animals from disinfected and tap water groups. Furthermore, statistical analyses showed that both time elapsed between samplings and water type significantly influenced the variation observed in the samples. Our results reveal that drinking water potentially affects gut microbiota composition. Additionally, the increase of typical drinking water clinically relevant and antibiotic resistance-associated bacteria in gut microbiota is a cause of concern. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. THE IMPACT OF ORTHOPHOSPHATE ON COPPER CORROSION AND CHLORINE DEMAND

    EPA Science Inventory

    In 1991, EPA promulgated the Lead and Copper Rule, which established a copper action level of 1.3 mg/L in a 1-liter, first-draw sample collected from the consumer’s tap. Excessive corrosion of copper can lead to elevated copper levels at the consumer's tap, and in some cases, can...

  6. Low Contribution of PbO2-Coated Lead Service Lines to Water Lead Contamination at the Tap

    EPA Science Inventory

    To determine if field experience corroborates that formation of stable PbO2 coatings on lead service lines (LSLs) provides an effective lead contamination control strategy, lead profile sampling was undertaken at eight home kitchen taps in three US cities (Newport, Rhode Island; ...

  7. An experimental study on the influence of water stagnation and temperature change on water quality in a full-scale domestic drinking water system.

    PubMed

    Zlatanović, Lj; van der Hoek, J P; Vreeburg, J H G

    2017-10-15

    The drinking water quality changes during the transport through distribution systems. Domestic drinking water systems (DDWSs), which include the plumbing between the water meter and consumer's taps, are the most critical points in which water quality may be affected. In distribution networks, the drinking water temperature and water residence time are regarded as indicators of the drinking water quality. This paper describes an experimental research on the influence of stagnation time and temperature change on drinking water quality in a full-scale DDWS. Two sets of stagnation experiments, during winter and summer months, with various stagnation intervals (up to 168 h of stagnation) were carried out. Water and biofilms were sampled at two different taps, a kitchen and a shower tap. Results from this study indicate that temperature and water stagnation affect both chemical and microbial quality in DDWSs, whereas microbial parameters in stagnant water appear to be driven by the temperature of fresh water. Biofilm formed in the shower pipe contained more total and intact cells than the kitchen pipe biofilm. Alphaproteobacteria were found to dominate in the shower biofilm (78% of all Proteobacteria), while in the kitchen tap biofilm Alphaproteobacteria, Betaproteobacteria and Gammaproteobacteria were evenly distributed. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. Perioperative transversus abdominis plane (TAP) blocks for analgesia after abdominal surgery.

    PubMed

    Charlton, Shona; Cyna, Allan M; Middleton, Philippa; Griffiths, James D

    2010-12-08

    The transversus abdominis plane (TAP) block is a peripheral nerve block which anaesthetises the abdominal wall. The increasing use of TAP block, as a form of pain relief after abdominal surgery warrants evaluation of its effectiveness as an adjunctive technique to routine care and, when compared with other analgesic techniques. To assess effects of TAP blocks (and variants) on postoperative analgesia requirements after abdominal surgery. We searched specialised registers of Cochrane Anaesthesia and Cochrane Pain, Palliative and Supportive Care Review Groups, CENTRAL, MEDLINE, EMBASE and CINAHL to June 2010. We included randomised controlled trials (RCTs) comparing TAP block or rectus sheath block with: no TAP or rectus sheath block; placebo; systemic, epidural or any other analgesia. At least two review authors assessed study eligibility and risk of bias, and extracted data. We included eight studies (358 participants), five assessing TAP blocks, three assessing rectus sheath blocks; with moderate risk of bias overall. All studies had a background of general anaesthesia in both arms in most cases.Compared with no TAP block or saline placebo, TAP block resulted in significantly less postoperative requirement for morphine at 24 hours (mean difference (MD) -21.95 mg, 95% confidence interval (CI) -37.91 to 5.96; five studies, 236 participants) and 48 hours (MD -28.50, 95% CI -38.92 to -18.08; one study of 50 participants) but not at two hours (all random-effects analyses). Pain at rest was significantly reduced in two studies, but not a third.Only one of three included studies of rectus sheath blocks found a reduction in postoperative analgesic requirements in participants receiving blocks. One study, assessing number of participants who were pain-free after their surgery, found more participants who received a rectus sheath block to be pain-free for up to 10 hours postoperatively. As with TAP blocks, rectus sheath blocks made no apparent impact on nausea and vomiting or sedation scores. No studies have compared TAP block with other analgesics such as epidural analgesia or local anaesthetic infiltration into the abdominal wound. There is only limited evidence to suggest use of perioperative TAP block reduces opioid consumption and pain scores after abdominal surgery when compared with no intervention or placebo. There is no apparent reduction in postoperative nausea and vomiting or sedation from the small numbers of studies to date. Many relevant studies are currently underway or awaiting publication.

  9. Objective Assessment of an Ionic Footbath (IonCleanse): Testing Its Ability to Remove Potentially Toxic Elements from the Body

    PubMed Central

    Kennedy, Deborah A.; Cooley, Kieran; Einarson, Thomas R.; Seely, Dugald

    2012-01-01

    Ionic footbaths are often used in holistic health centres and spas to aid in detoxification; however, claims that these machines eliminate toxins from the body have not been rigorously evaluated. In this proof-of-principle study, we sought to measure the release of potentially toxic elements from ionic footbaths into distilled and tap water with and without feet. Water samples were collected and analyzed following 30-minute ionic footbath sessions without feet using both distilled (n = 1) and tap water (n = 6) and following four ionic footbaths using tap water (once/week for 4 weeks) in six healthy participants. Urine collection samples were analyzed at four points during the study. Hair samples were analyzed for element concentrations at baseline and study conclusion. Contrary to claims made for the machine, there does not appear to be any specific induction of toxic element release through the feet when running the machine according to specifications. PMID:22174728

  10. Metal leaching in drinking water domestic distribution system: an Italian case study.

    PubMed

    Sorlini, Sabrina; Gialdini, Francesca; Collivignarelli, Carlo

    2014-01-01

    The objective of this study was to evaluate metal contamination of tap water in seven public buildings in Brescia (Italy). Two monitoring periods were performed using three different sampling methods (overnight stagnation, 30-min stagnation, and random daytime). The results show that the water parameters exceeding the international standards (Directive 98/83/EC) at the tap were lead (max = 363 μg/L), nickel (max = 184 μg/L), zinc (max = 4900 μg/L), and iron (max = 393 μg/L). Compared to the total number of tap water samples analyzed (122), the values higher than limits of Directive 98/83/EC were 17% for lead, 11% for nickel, 14% for zinc, and 7% for iron. Three buildings exceeded iron standard while five buildings exceeded the standard for nickel, lead, and zinc. Moreover, there is no evident correlation between the leaching of contaminants in the domestic distribution system and the age of the pipes while a significant influence is shown by the sampling methods.

  11. Correlation between lead levels in drinking water and mothers' breast milk: Dakahlia, Egypt.

    PubMed

    Mandour, Raafat A; Ghanem, Abdel-Aziz; El-Azab, Somaia M

    2013-04-01

    This study was performed on fifty-two drinking tap water samples (surface and groundwater) collected from different districts of Dakahlia Governorate and fifty-two breast milk samples from lactating mothers hosted in Dakahlia Governorate hospitals. All these samples were subjected to lead analysis. Lead level in drinking groundwater showed higher levels than in drinking surface water. Also, an elevation of lead levels in breast milk of mothers drinking groundwater was noticed when compared with that of mothers drinking surface water. The comparison between mean lead levels in drinking water and mothers' breast milk samples showed positive relationship. Lead concentrations in breast milk of the studied samples were elevated by exposure to smoking. We conclude that prolonged contact with lead plumbing can increase the lead content in tap water with subsequent increase in lead burden in infant fed formula and infant blood. Also, we recommend that chemical analyses must be carried out periodically for the surface and groundwater to ensure the water suitability for drinking purposes. Passive exposure to smoking during lactation should be avoided. Capsule: Prolonged contact with lead plumbing can increase the lead content in tap water with subsequent increase in lead burden in infant fed formula and infant blood.

  12. The health-related microbiological quality of bottled drinking water sold in Dar es Salaam, Tanzania.

    PubMed

    Kassenga, Gabriel R

    2007-03-01

    The consumption of bottled and plastic-bagged drinking water in Tanzania has increased largely because of the deteriorating quality of tap water. It is uncertain whether these water products are safe for drinking. In this study, the microbiological quality of bottled and plastic-bagged drinking water sold in Dar es Salaam, Tanzania, was investigated. One hundred and thirty samples representing 13 brands of bottled water collected from shops, supermarkets and street vendors were analysed for total coliform and faecal coliform organisms as well as heterotrophic bacteria. These were compared with 61 samples of tap water. Heterotrophic bacteria were detected in 92% of the bottled water samples analysed. Total and faecal coliform bacteria were present in 4.6% and 3.6%, respectively, of samples analysed with a tendency for higher contamination rates in plastic-bagged drinking water. Microbiological quality of tap water was found to be worse compared with bottled water, with 49.2% and 26.2% of sampling points showing the presence of total coliform and faecal coliform organisms, respectively. The results suggest caution and vigilance to avert outbreaks of waterborne diseases from these types of drinking water.

  13. The Canadian Geo-location Endeavour Using Isotopes and Trace Elements in Hair

    NASA Astrophysics Data System (ADS)

    Chartrand, Michelle M. G.; St-Jean, Gilles; Dalpe, Claude; Wojtyk, James

    2010-05-01

    The Canadian human hair provenance project has two main objectives: 1) to build a Canadian database of isotopes and trace elements from tap water and hair samples, and 2) to assess the extent of temporal effects on these samples. To address objective 1, a cross-Canada sampling campaign has been started to collect hair and tap water samples. In the past two years, our group has collected samples from the eastern part of Canada (Newfoundland, Nova Scotia, New Brunswick, Prince Edward Island, Quebec and Ontario). Water samples are divided into three groups - groundwater, surface water and bottled water. The GIS maps show the isotopic distribution of the tap water sources varies with latitude. Hair is analyzed for carbon (C), nitrogen (N) and hydrogen (H) isotopes. The C and N results show that in general, Canadians eat a typical diet showing a small isotopic variation. However, some cases will be presented which may explain why some people have C and N values outlying the collected sample average. In terms of H isotopes in human hair, GIS maps illustrate the distribution of this isotope in the eastern provinces of Canada. In some cases, a large variation in H was observed for the same locality with no significant difference in human activities and/or consumption. However, based on hair collected from across Canada from previous years, H isotopes in hair show a correlation to water collected from the same locality. To address objective 2, hair and tap water samples were collected at 4 month intervals (to represent different seasons in Canada) from several volunteers residing in two cities located in the province of Ontario (i.e. Sudbury and Ottawa) and one city from the province of Quebec (i.e. Montreal). For all isotopes measured, there was little variation observed over the course of the year in any individual from those small to medium-size cities. On-going sampling efforts will address if any variation may occur on a yearly basis.

  14. Variability in the chemistry of private drinking water supplies and the impact of domestic treatment systems on water quality.

    PubMed

    Ander, E L; Watts, M J; Smedley, P L; Hamilton, E M; Close, R; Crabbe, H; Fletcher, T; Rimell, A; Studden, M; Leonardi, G

    2016-12-01

    Tap water from 497 properties using private water supplies, in an area of metalliferous and arsenic mineralisation (Cornwall, UK), was measured to assess the extent of compliance with chemical drinking water quality standards, and how this is influenced by householder water treatment decisions. The proportion of analyses exceeding water quality standards were high, with 65 % of tap water samples exceeding one or more chemical standards. The highest exceedances for health-based standards were nitrate (11 %) and arsenic (5 %). Arsenic had a maximum observed concentration of 440 µg/L. Exceedances were also high for pH (47 %), manganese (12 %) and aluminium (7 %), for which standards are set primarily on aesthetic grounds. However, the highest observed concentrations of manganese and aluminium also exceeded relevant health-based guidelines. Significant reductions in concentrations of aluminium, cadmium, copper, lead and/or nickel were found in tap waters where households were successfully treating low-pH groundwaters, and similar adventitious results were found for arsenic and nickel where treatment was installed for iron and/or manganese removal, and successful treatment specifically to decrease tap water arsenic concentrations was observed at two properties where it was installed. However, 31 % of samples where pH treatment was reported had pH < 6.5 (the minimum value in the drinking water regulations), suggesting widespread problems with system maintenance. Other examples of ineffectual treatment are seen in failed responses post-treatment, including for nitrate. This demonstrates that even where the tap waters are considered to be treated, they may still fail one or more drinking water quality standards. We find that the degree of drinking water standard exceedances warrant further work to understand environmental controls and the location of high concentrations. We also found that residents were more willing to accept drinking water with high metal (iron and manganese) concentrations than international guidelines assume. These findings point to the need for regulators to reinforce the guidance on drinking water quality standards to private water supply users, and the benefits to long-term health of complying with these, even in areas where treated mains water is widely available.

  15. Contamination of hospital tap water: the survival and persistence of Pseudomonas aeruginosa on conventional and 'antimicrobial' outlet fittings.

    PubMed

    Hutchins, C F; Moore, G; Thompson, K-A; Webb, J; Walker, J T

    2017-10-01

    Pseudomonas aeruginosa infections have been linked to contaminated hospital taps, highlighting the potential for tap outlet fittings (OF) to harbour biofilm. P. aeruginosa may be transferred to OFs via contaminated cleaning cloths. Suggested interventions include flushing regimens and alternative OF designs. To investigate the transfer of P. aeruginosa from a contaminated cleaning cloth to conventional and 'antimicrobial/antibiofilm' OFs and to determine whether this contamination persists and/or leads to contamination of tap water. Microfibre cloths contaminated with P. aeruginosa (10 8  cfu/mL) were used to wipe four different types of OF [one of conventional design (OF-A) and three marketed as 'antimicrobial' and/or 'antibiofilm' (OF- B, -C and -D)]. OFs were inserted into an experimental water distribution system for up to 24 h. Survival was assessed by culture. Single and multiple water samples were collected and cultured for P. aeruginosa. The median number of P. aeruginosa transferred from cloth to OF was 5.7 × 10 5  cfu (OF-A), 1.9 × 10 6  cfu (OF-B), 1.4 × 10 5  cfu (OF-C) and 2.9 × 10 6  cfu (OF-D). Numbers declined on all OFs during the 24 h period with log reductions ranging from 3.5 (OF-C) to 5.2 (OF-B; P > 0.05). All water samples delivered immediately after OF contamination contained P. aeruginosa at ≥10 cfu per 100 mL. Contamination of water delivered from OF-A persisted despite continued flushing. Water delivered from OF-B did not contain P. aeruginosa beyond the first flush. Contaminated cleaning cloths may transfer P. aeruginosa to OFs, leading to contamination of tap water. Although not removing the potential for contamination, 'antimicrobial/antibiofilm' OFs may prevent P. aeruginosa from continually contaminating water delivered from the outlet. Copyright © 2017 The Healthcare Infection Society. All rights reserved.

  16. 43 CFR 29.6 - Financing, accounting, and audit.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... each Permittee within a reasonable time as to the date of the tanker loadings and the volumes of TAPS oil loaded. The Permittee will send an invoice for transportation charges for TAPS oil (which includes... to vessels, the amount of fees charged and collected, and the Owners of TAPS oil from whom such fees...

  17. Water quality monitoring records for estimating tap water arsenic and nitrate: a validation study.

    PubMed

    Searles Nielsen, Susan; Kuehn, Carrie M; Mueller, Beth A

    2010-01-28

    Tap water may be an important source of exposure to arsenic and nitrate. Obtaining and analyzing samples in the context of large studies of health effects can be expensive. As an alternative, studies might estimate contaminant levels in individual homes by using publicly available water quality monitoring records, either alone or in combination with geographic information systems (GIS). We examined the validity of records-based methods in Washington State, where arsenic and nitrate contamination is prevalent but generally observed at modest levels. Laboratory analysis of samples from 107 homes (median 0.6 microg/L arsenic, median 0.4 mg/L nitrate as nitrogen) served as our "gold standard." Using Spearman's rho we compared these measures to estimates obtained using only the homes' street addresses and recent and/or historical measures from publicly monitored water sources within specified distances (radii) ranging from one half mile to 10 miles. Agreement improved as distance decreased, but the proportion of homes for which we could estimate summary measures also decreased. When including all homes, agreement was 0.05-0.24 for arsenic (8 miles), and 0.31-0.33 for nitrate (6 miles). Focusing on the closest source yielded little improvement. Agreement was greatest among homes with private wells. For homes on a water system, agreement improved considerably if we included only sources serving the relevant system (rho = 0.29 for arsenic, rho = 0.60 for nitrate). Historical water quality databases show some promise for categorizing epidemiologic study participants in terms of relative tap water nitrate levels. Nonetheless, such records-based methods must be used with caution, and their use for arsenic may be limited.

  18. In vitro bioanalysis of drinking water from source to tap.

    PubMed

    Rosenmai, Anna Kjerstine; Lundqvist, Johan; le Godec, Théo; Ohlsson, Åsa; Tröger, Rikard; Hellman, Björn; Oskarsson, Agneta

    2018-08-01

    The presence of chemical pollutants in sources of drinking water is a key environmental problem threatening public health. Efficient removal of pollutants in drinking water treatment plants (DWTPs) is needed as well as methods for assessment of the total impact of all present chemicals on water quality. In the present study we have analyzed the bioactivity of water samples from source to tap, including effects of various water treatments in a DWTP, using a battery of cell-based bioassays, covering health-relevant endpoints. Reporter gene assays were used to analyze receptor activity of the aryl hydrocarbon receptor (AhR), estrogen receptor (ER), androgen receptor (AR), peroxisome proliferator-activated receptor alpha (PPARα) and induction of oxidative stress by the nuclear factor erythroid 2-related factor 2 (Nrf2). DNA damage was determined by Comet assay. Grab water samples were concentrated by HLB or ENV solid phase extraction and the water samples assayed at a relative enrichment factor of 50. The enrichment procedure did not induce any bioactivity. No bioactivity was detected in Milli-Q water or drinking water control samples. Induction of AhR, ER and Nrf2 activities was revealed in source to tap water samples. No cytotoxicity, PPARα or AR antagonist activity, or DNA damage were observed in any of the water samples. A low AR agonist activity was detected in a few samples of surface water, but not in the samples from the DWTP. The treatment steps at the DWTP, coagulation, granulated activated carbon filtration, UV disinfection and NH 2 Cl dosing had little or no effect on the AhR, Nrf2 and ER bioactivity. However, nanofiltration and passage through the distribution network drastically decreased AhR activity, while the effect on Nrf2 activity was more modest and no apparent effect was observed on ER activity. The present results suggest that bioassays are useful tools for evaluation of the efficiency of different treatment steps in DWTPs in reducing toxic activities. Bioassays of AhR and Nrf2 are useful for screening of effects of a broad range of chemicals in drinking water and ER activity can be monitored with a high sensitivity. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Bottled, filtered, and tap water use in Latino and non-Latino children.

    PubMed

    Hobson, Wendy L; Knochel, Miguel L; Byington, Carrie L; Young, Paul C; Hoff, Charles J; Buchi, Karen F

    2007-05-01

    To describe bottled, filtered, and tap water consumption and fluoride use among pediatric patients; to analyze differences between ethnic and socioeconomic groups; and to describe the frequency of physician-parent discussions regarding water consumption. Convenience sample survey. An urban public health clinic. Parents attending a public health clinic. The primary outcome measure was the prevalence of tap, filtered, and bottled water use. The secondary outcome measures were supplemental fluoride use and the percentage of patients reporting discussions of water consumption with their physician. A total of 216 parents (80.5% Latino and 19.5% non-Latino) completed the survey. Of the parents, 30.1% never drank tap water and 41.2% never gave it to their children. Latino parents were less likely than non-Latino parents to drink tap water (odds ratio, 0.26; 95% confidence interval, 0.10-0.67) and less likely to give tap water to their children (odds ratio, 0.32; 95% confidence interval, 0.15-0.70). More Latinos believed that tap water would make them sick (odds ratio, 5.63; 95% confidence interval, 2.17-14.54). Approximately 40% of children who never drank tap water were not receiving fluoride supplements. Of the lowest-income families (

  20. A comparison among tapentadol tamper-resistant formulations (TRF) and OxyContin® (non-TRF) in prescription opioid abusers

    PubMed Central

    Vosburg, Suzanne K.; Jones, Jermaine D.; Manubay, Jeanne M.; Ashworth, Judy B.; Shapiro, Douglas Y.; Comer, Sandra D.

    2013-01-01

    Aims To examine whether tamper-resistant formulations (TRFs) of tapentadol hydrochloride ER 50 mg (TAP50) and tapentadol hydrochloride 250 mg (TAP250) could be converted into forms amenable to intranasal (Study 1) or intravenous abuse (Study 2). Design Randomized, repeated-measures study designs were employed. A non-TRF of OxyContin® 40 mg (OXY40) served as a positive control. No drug was taken in either study. Setting The studies took place in an outpatient setting in New York, NY. Participants 25 experienced, healthy extended-release oxycodone abusers participated in each study. Measurements The primary outcome for Study 1 was percentage of participants who indicated they would snort the tampered tablets, while the primary outcome for Study 2 was percent yield of active drug in solution. Other descriptive variables such as time spent manipulating the tablets were also examined to better characterize tampering behaviors. Findings Tampered TRF tablets were less desirable than the tampered OXY40 tablets. Few individuals were willing to snort the TRF particles (TAP50: 24%, TAP250: 16%; OXY40: 100% p<.001). There was less drug extracted from the TAP50 tablet than from the OXY40 tablet (3.5% vs. 37.0%, p=.008), and no samples from the TAP250 tablets contained analyzable solutions of the drug. It took participants longer to tamper with the TAPs (Study 1: TAP50 vs. OXY40, p<.01; TAP250 vs. OXY40, p<.01; Study 2: TAP250 vs. OXY40, p<05). Conclusions Taptentadol TRF tablets were not well-liked by individuals who regularly tampered with extended-release oxycodone tablets. Employing tamper resistant technology may be a promising approach towards reducing the abuse potential of tapentadol ER. PMID:23316699

  1. Microprocessor controlled anodic stripping voltameter for trace metals analysis in tap water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clem, R.G.; Park, F.W.; Kirsten, F.A.

    1981-04-01

    The construction and use of a portable, microprocessor controlled anodic stripping voltameter for on-site simultaneous metal analysis of copper, lead and cadmium in tap water is discussed. The instrumental system is comprised of a programmable controller which permits keying in analytical parameters such as sparge time and plating time; a rotating cell for efficient oxygen removal and amalgam formation; and, a magnetic tape which can be used for data storage. Analysis time can be as short as 10 to 15 minutes. The stripping analysis is based on a pre-measurement step during which the metals from a water sample are concentratedmore » into a thin mercury film by deposition from an acetate solution of pH 4.5. The concentrated metals are then electrochemically dissolved from the film by application of a linearly increasing anodic potential. Typical peak-shaped curves are obtained. The heights of these curves are related to the concentration of metals in the water by calibration data. Results of tap water analysis showed 3 +- 1 ..mu..g/L lead, 22 +- 0.3 ..mu..g/L copper, and less than 0.2 ..mu..g/L cadmium for a Berkeley, California tap water, and 1 to 1000 ..mu..g/L Cu, 1 to 2 ..mu..g/L Pb for ten samples of Seattle, Washington tap water. Recommendations are given for a next generation instrument system.« less

  2. EVALUATING THE IMPACT OF WATER CHEMISTRY ON CUPROSOLVENCY AND COPPER CORROSION BY-PRODUCT USING A SIMPLE COPPER PIPE RECIRCULATING LOOP SYSTEM

    EPA Science Inventory

    1991, EPA publicized the Lead and Copper Rule (LCR),which set regulations to minimize the amount of lead copper in drinking water. The LCR set the copper action level at 1.3 mg/L in more then 10% of customer’s first-draw taps sampled. Potential health effects of copper include vo...

  3. From Source Water to Tap Water to Spa and Swimming Pool Water: Effects of Disinfectanta and Precursors and Implications for Exposure and Toxicity

    EPA Science Inventory

    Introduction The current study investigated the effect of different disinfection treatments on the disinfection by-products (DBPs) formed in finished drinking water vs. tap water vs. swimming pool water vs. spa waters. To this end, samples across the complete water pathway (untr...

  4. 40 CFR 141.86 - Monitoring requirements for lead and copper in tap water.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Monitoring requirements for lead and... § 141.86 Monitoring requirements for lead and copper in tap water. (a) Sample site location. (1) By the applicable date for commencement of monitoring under paragraph (d)(1) of this section, each water system...

  5. 40 CFR 141.86 - Monitoring requirements for lead and copper in tap water.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 24 2013-07-01 2013-07-01 false Monitoring requirements for lead and... § 141.86 Monitoring requirements for lead and copper in tap water. (a) Sample site location. (1) By the applicable date for commencement of monitoring under paragraph (d)(1) of this section, each water system...

  6. 40 CFR 141.86 - Monitoring requirements for lead and copper in tap water.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 24 2012-07-01 2012-07-01 false Monitoring requirements for lead and... § 141.86 Monitoring requirements for lead and copper in tap water. (a) Sample site location. (1) By the applicable date for commencement of monitoring under paragraph (d)(1) of this section, each water system...

  7. Hydrologic data for a subsurface waste-injection site at Mulberry, Florida; 1972-77

    USGS Publications Warehouse

    Wilson, William Edward; Parsons, David C.; Spechler, R.M.

    1979-01-01

    Since October 1972, industrial liquid waste has been injected into a brine aquifer of limestone and dolomite in Mulberry, FL., at a depth of more than 4,000 feet below land surface. During 1977, the injection rate was about 8.8 million gallons per month. To determine what effect the injected waste has on the ground-water body, water levels have been measured and water samples collected from two monitor wells that tap different permeable zones above the injection zone, and from a satellite monitor well that taps the injection zone. The monitor wells are in the annulus of the injection well, and the satellite monitor well is 2,291 feet from the injection well. This report updates previous data reports and includes all hydrologic data collected by the U.S. Geological Survey during 1972-77. Included is a table of well-construction data, a graph showing the volume of waste injected each month, and hydrographs of the annulus monitor wells and the satellite monitor well. (Woodard-USGS)

  8. Drinking water quality in a Mexico city university community: perception and preferences.

    PubMed

    Espinosa-García, Ana C; Díaz-Ávalos, Carlos; González-Villarreal, Fernando J; Val-Segura, Rafael; Malvaez-Orozco, Velvet; Mazari-Hiriart, Marisa

    2015-03-01

    A transversal study was conducted at the University City campus of the National Autonomous University of Mexico (UNAM) in Mexico City, with the goal of estimating the university community preference for drinking either tap water or bottled water and the reasons for their selection. A representative sample of three university community subpopulations (students, workers/administrative staff, and academic personnel) were interviewed with respect to their water consumption habits. The results showed that 75% of the university community drinks only bottled water and that the consumption of tap water is low. The interviewees responded that the main reason for this preference is the organoleptic features of tap water independent of quality. In general, the participants in this study do not trust the quality of the tap water, which could be caused by the facilities that distribute bottled water encouraging a general disinterest in learning about the origin and management of the tap water that is distributed on campus.

  9. A randomised controlled trial investigating the analgesic efficacy of transversus abdominis plane block for adult laparoscopic appendicectomy.

    PubMed

    Tupper-Carey, Darell Alexander; Fathil, Shahridan Mohd; Tan, Yin Kiat Glenn; Kan, Yuk Man; Cheong, Chern Yuen; Siddiqui, Fahad Javaid; Assam, Pryseley Nkouibert

    2017-08-01

    We conducted a single-centre, prospective randomised clinical trial to investigate the analgesic efficacy of transversus abdominis plane (TAP) block in adult patients undergoing laparoscopic appendicectomy. Patients undergoing urgent laparoscopic appendicectomy under general anaesthesia alone (control group) and general anaesthesia supplemented by TAP block (TAP intervention group) were compared. All patients received a multimodal analgesia regime, which included postoperative morphine via a patient-controlled analgesia device. The primary endpoints were morphine consumption at 12 hours and 24 hours postoperatively. Secondary endpoints included pain scores, incidence of nausea and vomiting, and time to hospital discharge. A total of 58 patients were recruited, with 29 patients in each group. Mean postoperative morphine consumption at 12 hours (control group: 11.45 ± 7.64 mg, TAP intervention group: 9.79 ± 8.09 mg; p = 0.4264) and 24 hours (control group: 13.38 ± 8.72 mg, TAP intervention group: 11.31 ± 8.66 mg; p = 0.3686) for the control and TAP intervention groups were not statistically different. Secondary outcomes were also not different between the two groups. Length of stay in the post-anaesthesia care unit was significantly shorter for the TAP intervention group, with a trend toward faster hospital discharge being observed. TAP block, a regional anaesthetic procedure performed immediately prior to skin incision for laparoscopic appendicectomy, did not significantly improve postoperative analgesia outcomes. Copyright: © Singapore Medical Association

  10. A statistical characterization of the finger tapping test: modeling, estimation, and applications.

    PubMed

    Austin, Daniel; McNames, James; Klein, Krystal; Jimison, Holly; Pavel, Misha

    2015-03-01

    Sensory-motor performance is indicative of both cognitive and physical function. The Halstead-Reitan finger tapping test is a measure of sensory-motor speed commonly used to assess function as part of a neuropsychological evaluation. Despite the widespread use of this test, the underlying motor and cognitive processes driving tapping behavior during the test are not well characterized or understood. This lack of understanding may make clinical inferences from test results about health or disease state less accurate because important aspects of the task such as variability or fatigue are unmeasured. To overcome these limitations, we enhanced the tapper with a sensor that enables us to more fully characterize all the aspects of tapping. This modification enabled us to decompose the tapping performance into six component phases and represent each phase with a set of parameters having clear functional interpretation. This results in a set of 29 total parameters for each trial, including change in tapping over time, and trial-to-trial and tap-to-tap variability. These parameters can be used to more precisely link different aspects of cognition or motor function to tapping behavior. We demonstrate the benefits of this new instrument with a simple hypothesis-driven trial comparing single and dual-task tapping.

  11. Water use and time analysis in ablution from taps

    NASA Astrophysics Data System (ADS)

    Zaied, Roubi A.

    2017-09-01

    There is a lack of water resources and an extreme use of potable water in our Arab region. Ablution from taps was studied since it is a repeated daily activity that consumes more water. Five different tap types are investigated for water consumption fashions including traditional mixing tap and automatic tap. Analyzing 100 experimental observations revealed that 22.7-28.8 % of ablution water is used for washing of feet and the largest water waste occurs during washing of face portions. Moreover, 30-47 % amount of water consumed in ablution from taps is wasted which can be saved if tap releases water only at moments of need. The push-type tap is being spread recently especially in airports. If it is intended for use in ablution facilities, batch duration and volume must be tuned. When each batch is 0.25 L of water and lasts for 3 s, 3 L are sufficient for one complete ablution in average which means considerable saving. A cost-benefit model is proposed for using different tap types and an economic feasibility study is performed on a case study. This analysis can help us to design better ablution systems.

  12. TAP 2: A finite element program for thermal analysis of convectively cooled structures

    NASA Technical Reports Server (NTRS)

    Thornton, E. A.

    1980-01-01

    A finite element computer program (TAP 2) for steady-state and transient thermal analyses of convectively cooled structures is presented. The program has a finite element library of six elements: two conduction/convection elements to model heat transfer in a solid, two convection elements to model heat transfer in a fluid, and two integrated conduction/convection elements to represent combined heat transfer in tubular and plate/fin fluid passages. Nonlinear thermal analysis due to temperature-dependent thermal parameters is performed using the Newton-Raphson iteration method. Transient analyses are performed using an implicit Crank-Nicolson time integration scheme with consistent or lumped capacitance matrices as an option. Program output includes nodal temperatures and element heat fluxes. Pressure drops in fluid passages may be computed as an option. User instructions and sample problems are presented in appendixes.

  13. Eco-friendly LC-MS/MS method for analysis of multi-class micropollutants in tap, fountain, and well water from northern Portugal.

    PubMed

    Barbosa, Marta O; Ribeiro, Ana R; Pereira, Manuel F R; Silva, Adrián M T

    2016-11-01

    Organic micropollutants present in drinking water (DW) may cause adverse effects for public health, and so reliable analytical methods are required to detect these pollutants at trace levels in DW. This work describes the first green analytical methodology for multi-class determination of 21 pollutants in DW: seven pesticides, an industrial compound, 12 pharmaceuticals, and a metabolite (some included in Directive 2013/39/EU or Decision 2015/495/EU). A solid-phase extraction procedure followed by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (offline SPE-UHPLC-MS/MS) method was optimized using eco-friendly solvents, achieving detection limits below 0.20 ng L -1 . The validated analytical method was successfully applied to DW samples from different sources (tap, fountain, and well waters) from different locations in the north of Portugal, as well as before and after bench-scale UV and ozonation experiments in spiked tap water samples. Thirteen compounds were detected, many of them not regulated yet, in the following order of frequency: diclofenac > norfluoxetine > atrazine > simazine > warfarin > metoprolol > alachlor > chlorfenvinphos > trimethoprim > clarithromycin ≈ carbamazepine ≈ PFOS > citalopram. Hazard quotients were also estimated for the quantified substances and suggested no adverse effects to humans. Graphical Abstract Occurrence and removal of multi-class micropollutants in drinking water, analyzed by an eco-friendly LC-MS/MS method.

  14. Reduced Sampling Size with Nanopipette for Tapping-Mode Scanning Probe Electrospray Ionization Mass Spectrometry Imaging

    PubMed Central

    Kohigashi, Tsuyoshi; Otsuka, Yoichi; Shimazu, Ryo; Matsumoto, Takuya; Iwata, Futoshi; Kawasaki, Hideya; Arakawa, Ryuichi

    2016-01-01

    Mass spectrometry imaging (MSI) with ambient sampling and ionization can rapidly and easily capture the distribution of chemical components in a solid sample. Because the spatial resolution of MSI is limited by the size of the sampling area, reducing sampling size is an important goal for high resolution MSI. Here, we report the first use of a nanopipette for sampling and ionization by tapping-mode scanning probe electrospray ionization (t-SPESI). The spot size of the sampling area of a dye molecular film on a glass substrate was decreased to 6 μm on average by using a nanopipette. On the other hand, ionization efficiency increased with decreasing solvent flow rate. Our results indicate the compatibility between a reduced sampling area and the ionization efficiency using a nanopipette. MSI of micropatterns of ink on a glass and a polymer substrate were also demonstrated. PMID:28101441

  15. Multi-pumping flow system for the determination of boron in eye drops, drinking water and ocean water.

    PubMed

    González, Pablo; Sixto, Alexandra; Knochen, Moisés

    2017-05-01

    A novel automated method for the determination of boron based on the use of pulsed flows was developed and applied to the determination of this element in samples of tap water, ocean water and eye drops. The method was implemented by means of a multi-pumping system consisting of three solenoid micropumps and a photometric detector and exploits the reaction of azomethine-H in the presence of boron. The system runs under control of an open-source microcontroller. The main operational parameters were optimized. Given the particular kinetics of the reaction, a stopped-flow period (1 or 5min) was included to allow for color development. The method presents linearity in the range 0.35-3.0mgL -1 , good precision (s r <3%), and detection and quantification limits of 0.10 and 0.35mgL -1 respectively. Samples of tap water or eye drops could be successfully analyzed employing a 1-minute stop time, providing a maximum sampling frequency of 32 samples h -1 . In order to overcome matrix effect caused by the high saline concentration, ocean water samples required stop times of 5min, providing a sampling frequency of 10 samples h -1 . Recoveries of 102% (eye drops), 94% (drinking water) and 93% (ocean water) were obtained. The method was considered accurate and fit for the purpose. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Bi-harmonic cantilever design for improved measurement sensitivity in tapping-mode atomic force microscopy.

    PubMed

    Loganathan, Muthukumaran; Bristow, Douglas A

    2014-04-01

    This paper presents a method and cantilever design for improving the mechanical measurement sensitivity in the atomic force microscopy (AFM) tapping mode. The method uses two harmonics in the drive signal to generate a bi-harmonic tapping trajectory. Mathematical analysis demonstrates that the wide-valley bi-harmonic tapping trajectory is as much as 70% more sensitive to changes in the sample topography than the standard single-harmonic trajectory typically used. Although standard AFM cantilevers can be driven in the bi-harmonic tapping trajectory, they require large forcing at the second harmonic. A design is presented for a bi-harmonic cantilever that has a second resonant mode at twice its first resonant mode, thereby capable of generating bi-harmonic trajectories with small forcing signals. Bi-harmonic cantilevers are fabricated by milling a small cantilever on the interior of a standard cantilever probe using a focused ion beam. Bi-harmonic drive signals are derived for standard cantilevers and bi-harmonic cantilevers. Experimental results demonstrate better than 30% improvement in measurement sensitivity using the bi-harmonic cantilever. Images obtained through bi-harmonic tapping exhibit improved sharpness and surface tracking, especially at high scan speeds and low force fields.

  17. Twin Anemia Polycythemia Sequence: Current Views on Pathogenesis, Diagnostic Criteria, Perinatal Management, and Outcome.

    PubMed

    Tollenaar, Lisanne S A; Slaghekke, Femke; Middeldorp, Johanna M; Klumper, Frans J; Haak, Monique C; Oepkes, Dick; Lopriore, Enrico

    2016-06-01

    Monochorionic twins share a single placenta and are connected with each other through vascular anastomoses. Unbalanced inter-twin blood transfusion may lead to various complications, including twin-to-twin transfusion syndrome (TTTS) and twin anemia polycythemia sequence (TAPS). TAPS was first described less than a decade ago, and the pathogenesis of TAPS results from slow blood transfusion from donor to recipient through a few minuscule vascular anastomoses. This gradually leads to anemia in the donor and polycythemia in the recipient, in the absence of twin oligo-polyhydramnios sequence (TOPS). TAPS may occur spontaneously in 3-5% of monochorionic twins or after laser surgery for TTTS. The prevalence of post-laser TAPS varies from 2% to 16% of TTTS cases, depending on the rate of residual anastomoses. Pre-natal diagnosis of TAPS is currently based on discordant measurements of the middle cerebral artery peak systolic velocity (MCA-PSV; >1.5 multiples of the median [MoM] in donors and 8 g/dL), and at least one of the following: reticulocyte count ratio >1.7 or minuscule placental anastomoses. Management includes expectant management, and intra-uterine blood transfusion (IUT) with or without partial exchange transfusion (PET) or fetoscopic laser surgery. Post-laser TAPS can be prevented by using the Solomon laser surgery technique. Short-term neonatal outcome ranges from isolated inter-twin Hb differences to severe neonatal morbidity and neonatal death. Long-term neonatal outcome in post-laser TAPS is comparable with long-term outcome after treated TTTS. This review summarizes the current knowledge after 10 years of research on the pathogenesis, diagnosis, management, and outcome in TAPS.

  18. The Relationship between a Linear Combination of Intelligence, Musical Background, Rhythm Ability and Tapping Ability to Typewriting Speed and Accuracy.

    ERIC Educational Resources Information Center

    Fante, Cheryl H.

    This study was conducted in an attempt to identify any predictor or combination of predictors of a beginning typewriting student's success. Variables of intelligence, rhythmic ability, musical background, and tapping ability were combined to study their relationship to typewriting speed and accuracy. A sample of 109 high school students was…

  19. The Recreational Water Cycle: From Source Water to Tap Water to Spa and Swimming Pool Water: Effects of Disinfectants and Precursors and Implications for Exposure and Toxicity

    EPA Science Inventory

    The current study investigates the effect of different disinfection treatments on the disinfection by-products (DBPs) formed in finished drinking water vs. tap water vs. swimming pool water vs. spa waters. To this end, complete water pathway samples (untreated source waters ->fi...

  20. 40 CFR 92.114 - Exhaust gas and particulate sampling and analytical system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... downstream of the analyzer. The gauge tap must be within 2 inches of the analyzer exit port. Gauge... must be used. The gauge tap must be within 2 inches of the analyzer entrance port. (vi) Calibration or.... Equivalent loadings (0.5 mg/1075 mm2 stain area) shall be used as target loadings when other filter sizes are...

  1. 40 CFR 92.114 - Exhaust gas and particulate sampling and analytical system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... downstream of the analyzer. The gauge tap must be within 2 inches of the analyzer exit port. Gauge... must be used. The gauge tap must be within 2 inches of the analyzer entrance port. (vi) Calibration or.... Equivalent loadings (0.5 mg/1075 mm2 stain area) shall be used as target loadings when other filter sizes are...

  2. Identification of Trihalomethanes (THMs) Levels in Water Supply: A Case Study in Perlis, Malaysia

    NASA Astrophysics Data System (ADS)

    Jalil, Mohd Faizal Ab; Hamidin, Nasrul; Anas Nagoor Gunny, Ahmad; Nihla Kamarudzaman, Ain

    2018-03-01

    In Malaysia, chlorination is used for drinking water disinfection at water treatment plants due to its cost-effectiveness and efficiency. However, the use of chlorine poses potential health risks due to the formation of disinfection by-products such as trihalomethanes (THMs). THMs are formed due to the reaction between chlorine and some natural organic matter. The objective of the study is to analyze the level of THMs in the water supply in Perlis, Malaysia. The water samples were collected from end-user tap water near the water treatment plant (WTP) located in Perlis, including Timah Tasoh WTP, Kampung Sungai Baru WTP, Arau Phase I, II, III, and IV WTPs. The THMs were analyzed using a Gas Chromatography-Mass Spectrometry (GC/MS). The results showed that the water supply from Timah Tasoh WTP generates the most THMs, whereas Kuala Sungai Baru shows the fewest amounts of total THMs. In conclusion, the presence of THMs in tap water has caused great concern since these components can cause cancer in humans. Therefore, the identification of THM formation is crucial in order to make sure that the tap water quality remains at acceptable safety levels.

  3. Association between finger tapping, attention, memory, and cognitive diagnosis in elderly patients.

    PubMed

    Rabinowitz, Israel; Lavner, Yizhar

    2014-08-01

    This study examined the association between spontaneous finger tapping and cognitive function, with a detailed analysis of the two main phases of finger tapping, the touch-phase and the off-phase. 170 elderly patients (83 men, 87 women; M age = 82.1 yr., SD = 6.2) underwent cognitive assessment including the Mini-Mental State Examination, a forward digit span test, and 15 sec. of finger tapping. Results indicated a significant increase in the length and variability of the finger-touch phase among participants with mild cognitive impairment or dementia compared to participants with no cognitive impairment, suggesting a relationship between finger tapping and attention, short-term memory, and cognitive diagnosis. Pattern classification analyses on the finger tapping parameters indicated a specificity of 0.91 and sensitivity of 0.52 for ruling out cognitive impairment.

  4. 77 FR 12281 - Williston Basin Interstate Pipeline Company; Notice of Request Under Blanket Authorization

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-29

    ... Natural Gas Act (NGA) as amended, to permanently operate a mainline natural gas sales tap located in... Commission and open to public inspection. \\1\\ 30 FERC ] 61,143 (1985). The new sales tap was installed as an... Commission's Regulations. The sales tap installation included a steel pipe riser with a shut-in valve and...

  5. Determination of Martian soil mineralogy and water content using the Thermal Analyzer for Planetary Soils (TAPS)

    NASA Technical Reports Server (NTRS)

    Gooding, James L.; Ming, Douglas W.; Allton, Judith H.; Byers, Terry B.; Dunn, Robert P.; Gibbons, Frank L.; Pate, Daniel B.; Polette, Thomas M.

    1992-01-01

    Physical and chemical interactions between the surface and atmosphere of Mars can be expected to embody a strong cause-and-effect relationship with the minerals comprising the martian regolith. Many of the minerals in soils and sediments are probably products of chemical weathering (involving surface/atmosphere or surface/hydrosphere reactions) that could be expected to subsequently influence the sorption of atmospheric gases and water vapor. Therefore, identification of the minerals in martian surface soils and sediments is essential for understanding both past and present interactions between the Mars surface and atmosphere. Clearly, the most definitive mineral analyses would be achieved with well-preserved samples returned to Earth-based laboratories. In advance of a Mars sample return mission, however, significant progress could be made with in situ experiments that fill current voids in knowledge about the presence or abundance of key soil minerals such as clays (layered-structured silicates), zeolites, and various salts, including carbonates. TAPS is intended to answer that challenge by providing first-order identification of soil and sediment minerals.

  6. Drinking water: a risk factor for high incidence of esophageal cancer in Anyang, China.

    PubMed

    Cao, Wenbo; Han, Jianying; Yuan, Yi; Xu, Zhixiang; Yang, Shengli; He, Weixin

    2016-06-01

    Anyang is known to be a high-incidence area of esophageal cancer (EC) in China. Among a long list of risk factors, the quality of drinking water was evaluated. We have selected 3806 individuals and collected 550 drinking water samples correspondent with this not-matched case-control survey. There are 531 EC patients included based on Population Cancer Registry from 92 townships, of which 3275 controls with long-lived aged over 90 years and free from EC are used as controls in the same regions. Our result suggests that the quality of drinking water is a highly associated risk factor for EC. The residential ecological environment and the quality of water resource positively link with each other. The analysis of water samples also demonstrated that the concentrations of methyl ethylamine, morpholine, N-methylbenzylamine, nitrate and chloride in water from springs and rivers are higher than those in well and tap water (P = 0.001). Micronuclei formation tests show that well water and tap water in these regions have no mutagenicity.

  7. A Unique Self-Sensing, Self-Actuating AFM Probe at Higher Eigenmodes

    PubMed Central

    Wu, Zhichao; Guo, Tong; Tao, Ran; Liu, Leihua; Chen, Jinping; Fu, Xing; Hu, Xiaotang

    2015-01-01

    With its unique structure, the Akiyama probe is a type of tuning fork atomic force microscope probe. The long, soft cantilever makes it possible to measure soft samples in tapping mode. In this article, some characteristics of the probe at its second eigenmode are revealed by use of finite element analysis (FEA) and experiments in a standard atmosphere. Although the signal-to-noise ratio in this environment is not good enough, the 2 nm resolution and 0.09 Hz/nm sensitivity prove that the Akiyama probe can be used at its second eigenmode under FM non-contact mode or low amplitude FM tapping mode, which means that it is easy to change the measuring method from normal tapping to small amplitude tapping or non-contact mode with the same probe and equipment. PMID:26580619

  8. Occurrence and Distribution of Organophosphate Flame Retardants/Plasticizers in Surface Waters, Tap Water, and Rainwater: Implications for Human Exposure.

    PubMed

    Kim, Un-Jung; Kannan, Kurunthachalam

    2018-04-27

    The occurrence and profiles of 14 triester organophosphate flame retardants (OPFRs) and plasticizers were investigated in surface water, tap water, rainwater, and seawater collected from New York State. In total, 150 samples collected from rivers ( n = 35), lakes ( n = 39), tap water ( n = 58), precipitation/rainwater ( n = 15), and seawater ( n = 3) were analyzed for 14 organophosphate esters (OPEs). An additional nine Hudson River water samples were collected periodically to delineate seasonal trends in OPE levels. The total concentrations of OPEs were found at part-per-trillion ranges, with average concentrations that ranged from 0.01 ng/L for tripropyl phosphate (TPP) in river water to 689 ng/L for tris(2-butoxyethyl)phosphate (TBOEP) in lake water. Tris(1-chloro-2-propyl)phosphate (TCIPP) was the most abundant compound among the investigated OPEs in all types of water. The concentrations of OPEs in river-, lake-, and rainwater were similar but >3 times higher than those found in tap water. Chlorinated alkyl OPFRs accounted for a major proportion of total concentrations. TCIPP, TBOEP, and triethyl phosphate (TEP) were found in >90% of the samples analyzed. Wet deposition fluxes for 14 OPFRs were estimated, on the basis of the concentrations measured in rainwater in Albany, New York, and the values were between 440 and 5250 ng/m 2 . Among several surface water bodies analyzed, samples from the Hudson River and Onondaga Lake contained elevated concentrations of OPEs. Estimated daily intake of OPEs via the ingestion of drinking water was up to 9.65 ng/kg body weight/day.

  9. A control approach to cross-coupling compensation of piezotube scanners in tapping-mode atomic force microscope imaging.

    PubMed

    Wu, Ying; Shi, Jian; Su, Chanmin; Zou, Qingze

    2009-04-01

    In this article, an approach based on the recently developed inversion-based iterative control (IIC) to cancel the cross-axis coupling effect of piezoelectric tube scanners (piezoscanners) in tapping-mode atomic force microscope (AFM) imaging is proposed. Cross-axis coupling effect generally exists in piezoscanners used for three-dimensional (x-y-z axes) nanopositioning in applications such as AFM, where the vertical z-axis movement can be generated by the lateral x-y axes scanning. Such x/y-to-z cross-coupling becomes pronounced when the scanning is at large range and/or at high speed. In AFM applications, the coupling-caused position errors, when large, can generate various adverse effects, including large imaging and topography distortions, and damage of the cantilever probe and/or the sample. This paper utilizes the IIC technique to obtain the control input to precisely track the coupling-caused x/y-to-z displacement (with sign-flipped). Then the obtained input is augmented as a feedforward control to the existing feedback control in tapping-mode imaging, resulting in the cancellation of the coupling effect. The proposed approach is illustrated through two exemplary applications in industry, the pole-tip recession examination, and the nanoasperity measurement on hard-disk drive. Experimental results show that the x/y-to-z coupling effect in large-range (20 and 45 microm) tapping-mode imaging at both low to high scan rates (2, 12.2 to 24.4 Hz) can be effectively removed.

  10. Yield modeling of acoustic charge transport transversal filters

    NASA Technical Reports Server (NTRS)

    Kenney, J. S.; May, G. S.; Hunt, W. D.

    1995-01-01

    This paper presents a yield model for acoustic charge transport transversal filters. This model differs from previous IC yield models in that it does not assume that individual failures of the nondestructive sensing taps necessarily cause a device failure. A redundancy in the number of taps included in the design is explained. Poisson statistics are used to describe the tap failures, weighted over a uniform defect density distribution. A representative design example is presented. The minimum number of taps needed to realize the filter is calculated, and tap weights for various numbers of redundant taps are calculated. The critical area for device failure is calculated for each level of redundancy. Yield is predicted for a range of defect densities and redundancies. To verify the model, a Monte Carlo simulation is performed on an equivalent circuit model of the device. The results of the yield model are then compared to the Monte Carlo simulation. Better than 95% agreement was obtained for the Poisson model with redundant taps ranging from 30% to 150% over the minimum.

  11. Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

    PubMed Central

    Sadeghi, Ramezan; Kobarfard, Farzad; Yazdanpanah, Hassan; Eslamizad, Samira; Bayate, Mitra

    2016-01-01

    Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and water for injection. Dispersive liquid-liquid microextraction procedure combined with gas chromatography-mass spectrometry was used for the extraction and determination of PAHs in the samples. Under the optimized conditions, the range of extraction recoveries and relative standard deviations (RSDs) of PAHs in water using internal standard (anthracene-d10) were in the range of 71-90% and 4-16%, respectively. Limit of detection for different PAHs were between 0.03 and 0.1 ngmL-1. The concentration of PAHs in all tap water as well as water for injection samples were lower than the limit of quantification of PAHs. This is the first study addressing the occurrence of PAHs in water for injection samples in Iran using dispersive liquid-liquid micro extraction procedure combined with gas chromatography-mass spectrometry. PMID:27642318

  12. Antibiotics in Drinking Water in Shanghai and Their Contribution to Antibiotic Exposure of School Children.

    PubMed

    Wang, Hexing; Wang, Na; Wang, Bin; Zhao, Qi; Fang, Hong; Fu, Chaowei; Tang, Chuanxi; Jiang, Feng; Zhou, Ying; Chen, Yue; Jiang, Qingwu

    2016-03-01

    A variety of antibiotics have been found in aquatic environments, but antibiotics in drinking water and their contribution to antibiotic exposure in human are not well-explored. For this, representative drinking water samples and 530 urine samples from schoolchildren were selected in Shanghai, and 21 common antibiotics (five macrolides, two β-lactams, three tetracyclines, four fluoquinolones, four sulfonamides, and three phenicols) were measured in water samples and urines by isotope dilution two-dimensional ultraperformance liquid chromatography coupled with high-resolution quadrupole time-of-flight mass spectrometry. Drinking water included 46 terminal tap water samples from different spots in the distribution system of the city, 45 bottled water samples from 14 common brands, and eight barreled water samples of different brands. Of 21 antibiotics, only florfenicol and thiamphenicol were found in tap water, with the median concentrations of 0.0089 ng/mL and 0.0064 ng/mL, respectively; only florfenicol was found in three bottled water samples from a same brand, with the concentrations ranging from 0.00060 to 0.0010 ng/mL; no antibiotics were found in barreled water. In contrast, besides florfenicol and thiamphenicol, an additional 17 antibiotics were detected in urine samples, and the total daily exposure doses and detection frequencies of florfenicol and thiamphenicol based on urine samples were significantly and substantially higher than their predicted daily exposure doses and detection frequencies from drinking water by Monte Carlo Simulation. These data indicated that drinking water was contaminated by some antibiotics in Shanghai, but played a limited role in antibiotic exposure of children.

  13. Sampling in schools and large institutional buildings: Implications for regulations, exposure and management of lead and copper.

    PubMed

    Doré, Evelyne; Deshommes, Elise; Andrews, Robert C; Nour, Shokoufeh; Prévost, Michèle

    2018-04-21

    Legacy lead and copper components are ubiquitous in plumbing of large buildings including schools that serve children most vulnerable to lead exposure. Lead and copper samples must be collected after varying stagnation times and interpreted in reference to different thresholds. A total of 130 outlets (fountains, bathroom and kitchen taps) were sampled for dissolved and particulate lead as well as copper. Sampling was conducted at 8 schools and 3 institutional (non-residential) buildings served by municipal water of varying corrosivity, with and without corrosion control (CC), and without a lead service line. Samples included first draw following overnight stagnation (>8h), partial (30 s) and fully (5 min) flushed, and first draw after 30 min of stagnation. Total lead concentrations in first draw samples after overnight stagnation varied widely from 0.07 to 19.9 μg Pb/L (median: 1.7 μg Pb/L) for large buildings served with non-corrosive water. Higher concentrations were observed in schools with corrosive water without CC (0.9-201 μg Pb/L, median: 14.3 μg Pb/L), while levels in schools with CC ranged from 0.2 to 45.1 μg Pb/L (median: 2.1 μg Pb/L). Partial flushing (30 s) and full flushing (5 min) reduced concentrations by 88% and 92% respectively for corrosive waters without CC. Lead concentrations were <10 μg Pb/L in all samples following 5 min of flushing. However, after only 30 min of stagnation, first draw concentrations increased back to >45% than values in 1st draw samples collected after overnight stagnation. Concentrations of particulate Pb varied widely (≥0.02-846 μg Pb/L) and was found to be the cause of very high total Pb concentrations in the 2% of samples exceeding 50 μg Pb/L. Pb levels across outlets within the same building varied widely (up to 1000X) especially in corrosive water (0.85-851 μg Pb/L after 30MS) confirming the need to sample at each outlet to identify high risk taps. Based on the much higher concentrations observed in first draw samples, even after a short stagnation, the first 250mL should be discarded unless no sources of lead are present. Results question the cost-benefit of daily or weekly flushing as a remediation strategy. As such, current regulatory requirements may fail to protect children as they may not identify problematic taps and effective mitigation measures. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Drinking water management: health risk perceptions and choices in First Nations and non-First Nations communities in Canada.

    PubMed

    Dupont, Diane; Waldner, Cheryl; Bharadwaj, Lalita; Plummer, Ryan; Carter, Blair; Cave, Kate; Zagozewski, Rebecca

    2014-05-30

    The relationship between tap water and health has been a topic of public concern and calls for better management in Canada since well-publicized contamination events in two provinces (Ontario and Saskatchewan) in 2000-2001. This study reports the perspectives on health risks from tap water and corresponding use of, and spending on, bottled water in a number of different communities in Canada. In 2009-2010, four First Nations communities (three from Ontario and one from Saskatchewan) and a geographically diverse sample of non-First Nations Canadians were surveyed about their beliefs concerning health risks from tap water and their spending practices for bottled water as a substitute. Responses to five identical questions were examined, revealing that survey respondents from Ontario First Nations communities were more likely than non-First Nations Canadians to believe bottled water is safer than tap water (OR 1.6); more likely to report someone became ill from tap water (OR 3.6); more likely to express water and health concerns related to tap water consumption (OR 2.4); and more likely to spend more on bottled water (OR 4.9). On the other hand, participants from one Saskatchewan First Nations community were less likely than non-First Nations Canadians to believe that someone had become ill from drinking tap water (OR 3.8), less likely to believe bottled water is safer than tap (OR 2.0), and less likely to have health concerns with tap water (OR 1.5). These differences, however, did not translate into differences in the likelihood of high bottled water expenditures or being a 100% bottled water consumer. The paper discusses how the differences observed may be related to water supply and regulation, trust, perceived control, cultural background, location, and past experience.

  15. Occurrence, Source, and Human Infection Potential of Cryptosporidium and Giardia spp. in Source and Tap Water in Shanghai, China▿

    PubMed Central

    Feng, Yaoyu; Zhao, Xukun; Chen, Jiaxu; Jin, Wei; Zhou, Xiaonong; Li, Na; Wang, Lin; Xiao, Lihua

    2011-01-01

    Genotyping studies on the source and human infection potential of Cryptosporidium oocysts in water have been almost exclusively conducted in industrialized nations. In this study, 50 source water samples and 30 tap water samples were collected in Shanghai, China, and analyzed by the U.S. Environmental Protection Agency (EPA) Method 1623. To find a cost-effective method to replace the filtration procedure, the water samples were also concentrated by calcium carbonate flocculation (CCF). Of the 50 source water samples, 32% were positive for Cryptosporidium and 18% for Giardia by Method 1623, whereas 22% were positive for Cryptosporidium and 10% for Giardia by microscopy of CCF concentrates. When CCF was combined with PCR for detection, the occurrence of Cryptosporidium (28%) was similar to that obtained by Method 1623. Genotyping of Cryptosporidium in 17 water samples identified the presence of C. andersoni in 14 water samples, C. suis in 7 water samples, C. baileyi in 2 water samples, C. meleagridis in 1 water sample, and C. hominis in 1 water sample. Therefore, farm animals, especially cattle and pigs, were the major sources of water contamination in Shanghai source water, and most oocysts found in source water in the area were not infectious to humans. Cryptosporidium oocysts were found in 2 of 30 tap water samples. The combined use of CCF for concentration and PCR for detection and genotyping provides a less expensive alternative to filtration and fluorescence microscopy for accurate assessment of Cryptosporidium contamination in water, although the results from this method are semiquantitative. PMID:21498768

  16. Evaluation of on-line concentration coupled to liquid chromatography tandem mass spectrometry for the quantification of neonicotinoids and fipronil in surface water and tap water.

    PubMed

    Montiel-León, Juan Manuel; Duy, Sung Vo; Munoz, Gabriel; Amyot, Marc; Sauvé, Sébastien

    2018-04-01

    A study was initiated to investigate a fast and reliable method for the determination of selected systemic insecticides in water matrixes and to evaluate potential sources of bias in their analysis. Acetamiprid, clothianidin, desnitro-imidacloprid, dinotefuran, fipronil, imidacloprid, nitenpyram, thiacloprid, and thiamethoxam were amenable to analysis via on-line sample enrichment hyphenated to ultra-high-performance liquid chromatography tandem mass spectrometry. The selection of on-line solid-phase extraction parameters was dictated by a multicriterion desirability approach. A 2-mL on-line injection volume with a 1500 μL min -1 loading flow rate met the objectives sought in terms of chromatographic requirements, extraction efficiency, sensitivity, and precision. A total analysis time of 8 min per sample was obtained with method limits of detection in the range of 0.1-5 ng L -1 for the scope of targeted analytes. Automation at the sample concentration step yielded intraday and interday precisions in the range of 1-23 and 2-26%, respectively. Factors that could affect the whole method accuracy were further evaluated in matrix-specific experiments. The impact of the initial filtration step on analyte recovery was evaluated in ultra-pure water, tap water, and surface water. Out of the nine membranes tested, glass fiber filters and polyester filters appeared as the most appropriate materials. Sample storage stability was also investigated across the three matrix types; the targeted analytes displayed suitable stability during 28 days at either 4 °C or - 20 °C, with little deviations (± 10%) with respect to the initial T 0 concentration. Method applicability was demonstrated in a range of tap water and surface water samples from the province of Québec, Canada. Results from the present survey indicated a predominance of thiamethoxam (< 0.5-10 and 3-61 ng L -1 in tap water and river water, respectively), clothianidin (< 0.5-6 and 2-88 ng L -1 in tap water and river water, respectively), and imidacloprid (< 0.1-1 and 0.8-38 ng L -1 in tap water and river water, respectively) among the targeted analytes. Graphical abstract ᅟ Development of solid-phase extraction coupled on-line to UHPLC-MS/MS for the rapid screening of systemic insecticides in water.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barrett, Christopher A.; Martinez, Alonzo; McNamara, Bruce K.

    International Atom Energy Agency (IAEA) safeguard verification measures in gaseous centrifuge enrichment plants (GCEPs) rely on environmental sampling, non-destructive assay (NDA), and destructive assay (DA) sampling and analysis to determine uranium enrichment. UF6 bias defect measurements are made by DA sampling and analysis to assure that enrichment is consistent with declarations. DA samples are collected from a limited number of cylinders for high precision, offsite mass spectrometer analysis. Samples are typically drawn from a sampling tap into a UF6 sample bottle, then packaged, sealed, and shipped under IAEA chain of custody to an offsite analytical laboratory. Future DA safeguard measuresmore » may require improvements in efficiency and effectiveness as GCEP capacities increase and UF6 shipping regulations become increasingly more restrictive. The Pacific Northwest National Laboratory (PNNL) DA sampler concept and Laser Ablation Absorption Ratio Spectrometry (LAARS) assay method are under development to potentially provide DA safeguard tools that increase inspection effectiveness and reduce sample shipping constraints. The PNNL DA sampler concept uses a handheld sampler to collect DA samples for either onsite LAARS assay or offsite laboratory analysis. The DA sampler design will use a small sampling planchet that is coated with an adsorptive film to collect controlled quantities of UF6 gas directly from a cylinder or process sampling tap. Development efforts are currently underway at PNNL to enhance LAARS assay performance to allow high-precision onsite bias defect measurements. In this paper, we report on the experimental investigation to develop adsorptive films for the PNNL DA sampler concept. These films are intended to efficiently capture UF6 and then stabilize the collected DA sample prior to onsite LAARS or offsite laboratory analysis. Several porous material composite films were investigated, including a film designed to maximize the chemical adsorption and binding of gaseous UF6 onto the sampling planchet.« less

  18. Occurrence of antidepressant residues in the sewage-impacted Vistula and Utrata rivers and in tap water in Warsaw (Poland).

    PubMed

    Giebułtowicz, Joanna; Nałęcz-Jawecki, Grzegorz

    2014-06-01

    Antidepressants, even at low concentrations, can reveal some adverse effects on aquatic life due to disturbing homeostasis throughout the central and peripheral nervous system both in vertebrates and invertebrates. To date there have not been any reports regarding the presence of these pharmaceuticals in surface and tap waters in Eastern Europe. Therefore the aim of this study was to determine the presence of 21 antidepressant pharmaceuticals at specific points of the main Polish river - the Vistula, a smaller river of the Warsaw region - the Utrata, as well as in tap water samples of Warsaw. Samples were collected twice at one month intervals and analysed using solid-phase extraction (SPE) technique coupled with the liquid chromatography-electrospray ionisation-tandem mass spectrometer (LC-MS/MS) method operated under the multiple reaction monitoring mode (MRM). This is the first study where active compounds such as moclobemid or trazodone in the environment have been investigated. Environmental risk assessment of antidepressants in Poland was estimated on the basis of annuals sale data extracted from the NFZ (Narodowy Fundusz Zdrowia-National Health Service) base of reimbursed pharmaceuticals(1). Predicted environmental concentration (PEC) of target pharmaceuticals were compared with their measured concentration (MEC). Moreover, the application of the EMEA/CHMP guideline for environmental risk assessment of the antidepressants was discussed. The highest concentration of antidepressants was observed in the small river Utrata. In tap water only trace amounts of antidepressants including citalopram (up to 1.5ng/l), mianserin (up to 0.9ng/l), sertraline (<3.1ng/l), moclobemid (up to 0.3ng/l) and venlafaxine (up to 1.9ng/l) were detected. However this highlights their inadequate elimination in the drinking waste treatment facility. The presence of antidepressants in drinking water and the aquatic environment could have long-term effects even at low exposure level, especially since synergy amongst pharmaceutical pollutants may occur. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. On the origin of amplitude reduction mechanism in tapping mode atomic force microscopy

    NASA Astrophysics Data System (ADS)

    Keyvani, Aliasghar; Sadeghian, Hamed; Goosen, Hans; van Keulen, Fred

    2018-04-01

    The origin of amplitude reduction in Tapping Mode Atomic Force Microscopy (TM-AFM) is typically attributed to the shift in resonance frequency of the cantilever due to the nonlinear tip-sample interactions. In this paper, we present a different insight into the same problem which, besides explaining the amplitude reduction mechanism, provides a simple reasoning for the relationship between tip-sample interactions and operation parameters (amplitude and frequency). The proposed formulation, which attributes the amplitude reduction to an interference between the tip-sample and dither force, only deals with the linear part of the system; however, it fully agrees with experimental results and numerical solutions of the full nonlinear model of TM-AFM.

  20. Determining Content Validity for the Transition Awareness and Possibilities Scale (TAPS)

    ERIC Educational Resources Information Center

    Ross, Melynda Burck

    2011-01-01

    The Transition Awareness & Possibilities Scale (TAPS) was crafted after an extensive review of literature was conducted to find research that examined and described specific aspects of transition programming: inputs, including supports and skill instruction; processes, including parent and support provider perceptions of the transition experience;…

  1. A sensitive multi-residue method for the determination of 35 micropollutants including pharmaceuticals, iodinated contrast media and pesticides in water.

    PubMed

    Valls-Cantenys, Carme; Scheurer, Marco; Iglesias, Mònica; Sacher, Frank; Brauch, Heinz-Jürgen; Salvadó, Victoria

    2016-09-01

    A sensitive, multi-residue method using solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed to determine a representative group of 35 analytes, including corrosion inhibitors, pesticides and pharmaceuticals such as analgesic and anti-inflammatory drugs, five iodinated contrast media, β-blockers and some of their metabolites and transformation products in water samples. Few other methods are capable of determining such a broad range of contrast media together with other analytes. We studied the parameters affecting the extraction of the target analytes, including sorbent selection and extraction conditions, their chromatographic separation (mobile phase composition and column) and detection conditions using two ionisation sources: electrospray ionisation (ESI) and atmospheric pressure chemical ionisation (APCI). In order to correct matrix effects, a total of 20 surrogate/internal standards were used. ESI was found to have better sensitivity than APCI. Recoveries ranging from 79 to 134 % for tap water and 66 to 144 % for surface water were obtained. Intra-day precision, calculated as relative standard deviation, was below 34 % for tap water and below 21 % for surface water, groundwater and effluent wastewater. Method quantification limits (MQL) were in the low ng L(-1) range, except for the contrast agents iomeprol, amidotrizoic acid and iohexol (22, 25.5 and 17.9 ng L(-1), respectively). Finally, the method was applied to the analysis of 56 real water samples as part of the validation procedure. All of the compounds were detected in at least some of the water samples analysed. Graphical Abstract Multi-residue method for the determination of micropollutants including pharmaceuticals, iodinated contrast media and pesticides in waters by LC-MS/MS.

  2. Word-initial rhotic clusters in Spanish-speaking preschoolers in Chile and Granada, Spain.

    PubMed

    Perez, Denisse; Vivar, Pilar; Bernhardt, Barbara May; Mendoza, Elvira; Ávila, Carmen; Carballo, Gloria; Fresneda, Dolores; Muñoz, Juana; Vergara, Patricio

    2018-01-01

    The current paper describes Spanish acquisition of rhotic onset clusters. Data are also provided on related singleton taps/trills and /l/ as a singleton and in clusters. Participants included 9 typically developing (TD) toddlers and 30 TD preschoolers in Chile, and 30 TD preschoolers and 29 with protracted phonological development (PPD) in Granada, Spain. Results showed age and developmental group effects. Preservation of cluster timing units preceded segmental accuracy, especially in stressed syllables. Tap clusters versus singleton trills were variable in order of mastery, some children mastering clusters first, and others, the trill. Rhotics were acquired later than /l/. In early development, mismatches (errors) involved primarily deletion of taps; where substitutions occurred, [j] frequently replaced tap. In later development, [l] more frequently replaced tap; where taps did occur, vowel epenthesis sometimes occurred. The data serve as a criterion reference database for onset cluster acquisition in Chilean and Granada Spanish.

  3. Time-Reversal Based Range Extension Technique for Ultra-Wideband (UWB) Sensors and Applications in Tactical Communications and Networking

    DTIC Science & Technology

    2008-10-16

    signal from the signal generator is also used to synchronize DSO to record the data of the received signal. The tapped -delay-line model of CIR will...between each filter tap . The output y(t) — h(t) *x(t) is then uniformly sampled with sampling period Ts. 1 ’s follows the relation Ta/Th — q, where q... eft ) ProbtagPake ^ p(l> ’HO PriHretuHg Figure 5.5: An equivalent block diagram of channel estimation The success of recovery relies on the

  4. Rapid Detection of Melamine in Tap Water and Milk Using Conjugated "One-Step" Molecularly Imprinted Polymers-Surface Enhanced Raman Spectroscopic Sensor.

    PubMed

    Hu, Yaxi; Lu, Xiaonan

    2016-05-01

    An innovative "one-step" sensor conjugating molecularly imprinted polymers and surface enhanced Raman spectroscopic-active substrate (MIPs-SERS) was investigated for simultaneous extraction and determination of melamine in tap water and milk. This sensor was fabricated by integrating silver nanoparticles (AgNPs) with MIPs synthesized by bulk polymerization of melamine (template), methacrylic acid (functional monomer), ethylene glycol dimethacrylate (cross-linking agent), and 2,2'-azobisisobutyronitrile (initiator). Static and kinetic adsorption tests validated the specific affinity of MIPs-AgNPs to melamine and the rapid adsorption equilibration rate. Principal component analysis segregated SERS spectral features of tap water and milk samples with different melamine concentrations. Partial least squares regression models correlated melamine concentrations in tap water and skim milk with SERS spectral features. The limit of detection (LOD) and limit of quantification (LOQ) of melamine in tap water were determined as 0.0019 and 0.0064 mmol/L, while the LOD and LOQ were 0.0165 and 0.055 mmol/L for the determination of melamine in skim milk. However, this sensor is not ideal to quantify melamine in tap water and skim milk. By conjugating MIPs with SERS-active substrate (that is, AgNPs), reproducibility of SERS spectral features was increased, resulting in more accurate detection. The time required to determine melamine in tap water and milk were 6 and 25 min, respectively. The low LOD, LOQ, and rapid detection confirm the potential of applying this sensor for accurate and high-throughput detection of melamine in tap water and milk. © 2016 Institute of Food Technologists®

  5. TAp73 is essential for germ cell adhesion and maturation in testis

    PubMed Central

    Holembowski, Lena; Kramer, Daniela; Riedel, Dietmar; Sordella, Raffaella; Nemajerova, Alice; Dobbelstein, Matthias

    2014-01-01

    A core evolutionary function of the p53 family is to protect the genomic integrity of gametes. However, the role of p73 in the male germ line is unknown. Here, we reveal that TAp73 unexpectedly functions as an adhesion and maturation factor of the seminiferous epithelium orchestrating spermiogenesis. TAp73 knockout (TAp73KO) and p73KO mice, but not ΔNp73KO mice, display a “near-empty seminiferous tubule” phenotype due to massive premature loss of immature germ cells. The cellular basis of this phenotype is defective cell–cell adhesions of developing germ cells to Sertoli nurse cells, with likely secondary degeneration of Sertoli cells, including the blood–testis barrier, which leads to disruption of the adhesive integrity and maturation of the germ epithelium. At the molecular level, TAp73, which is produced in germ cells, controls a coordinated transcriptional program of adhesion- and migration-related proteins including peptidase inhibitors, proteases, receptors, and integrins required for germ–Sertoli cell adhesion and dynamic junctional restructuring. Thus, we propose the testis as a unique organ with strict division of labor among all family members: p63 and p53 safeguard germ line fidelity, whereas TAp73 ensures fertility by enabling sperm maturation. PMID:24662569

  6. Mentoring community-based trainee assistant practitioners: a case study.

    PubMed

    Griggs, Chloe

    2012-07-01

    The healthcare workforce is changing, and the introduction of assistant practitioner roles in the community presents exciting opportunities for the unregistered workforce. Healthcare assistants wishing to become assistant practitioners are undertaking foundation degrees. During this period of study, they require support and supervision from a mentor to perform competencies; however, mentors are often poorly prepared for this role. This small-scale qualitative exploratory study sought to gain trainee assistant practitioner (TAP), mentor and management perspective on the level of support needed. Findings indicate that TAPs struggle for recognition and student/learner status; there was an assumption that mentors would be adequately equipped to mentor TAPs, and poor mentor preparation was linked to negative student experiences. This article considers the key factors, time and commitment, required to support TAP learners in the workplace. Further, it questions who is best placed to mentor TAPs. Recommendations include an increased level of preparation for mentors, a joint induction programme for TAPs and mentors, a raised profile of the assistant practitioner role within the wider healthcare team, recognition of the TAP as a learner, and allocated time for quality mentorship.

  7. The neural basis of audiomotor entrainment: an ALE meta-analysis

    PubMed Central

    Chauvigné, Léa A. S.; Gitau, Kevin M.; Brown, Steven

    2014-01-01

    Synchronization of body movement to an acoustic rhythm is a major form of entrainment, such as occurs in dance. This is exemplified in experimental studies of finger tapping. Entrainment to a beat is contrasted with movement that is internally driven and is therefore self-paced. In order to examine brain areas important for entrainment to an acoustic beat, we meta-analyzed the functional neuroimaging literature on finger tapping (43 studies) using activation likelihood estimation (ALE) meta-analysis with a focus on the contrast between externally-paced and self-paced tapping. The results demonstrated a dissociation between two subcortical systems involved in timing, namely the cerebellum and the basal ganglia. Externally-paced tapping highlighted the importance of the spinocerebellum, most especially the vermis, which was not activated at all by self-paced tapping. In contrast, the basal ganglia, including the putamen and globus pallidus, were active during both types of tapping, but preferentially during self-paced tapping. These results suggest a central role for the spinocerebellum in audiomotor entrainment. We conclude with a theoretical discussion about the various forms of entrainment in humans and other animals. PMID:25324765

  8. Impact analysis of tap switch out of step for converter transformer

    NASA Astrophysics Data System (ADS)

    Hong-yue, ZHANG; Zhen-hua, ZHANG; Zhang-xue, XIONG; Gao-wang, YU

    2017-06-01

    AC transformer load regulation is mainly used to adjust the load side voltage level, improve the quality of power supply, the voltage range is relatively narrow. In DC system, converter transformer is the core equipment of AC and DC power converter and inverter. converter transformer tap adjustment can maintain the normal operation of the converter in small angle range control, the absorption of reactive power, economic operation, valve less stress, valve damping circuit loss, AC / DC harmonic component is also smaller. In this way, the tap switch action is more frequent, and a large range of the tap switch adjustment is required. Converter transformer with a more load voltage regulation switch, the voltage regulation range of the switch is generally 20~30%, the adjustment of each file is 1%~2%. Recently it is often found that the tap switch of Converter Transformers is out of step in Converter station. In this paper, it is analyzed in detail the impact of tap switch out of step for differential protection, overexcitation protection and zero sequence over current protection. Analysis results show that: the tap switch out of step has no effect on the differential protection and the overexcitation protection including the tap switch. But the tap switch out of step has effect on zero sequence overcurrent protection of out of step star-angle converter transformer. The zero sequence overcurrent protection will trip when the tap switch out of step is greater than 3 for out of step star-angle converter transformer.

  9. Risk Assessment of Exposure to Lead in Tap Water among Residents of Seri Kembangan, Selangor State, Malaysia

    PubMed Central

    C. S., Lim; M. S., Shaharuddin; W. Y., Sam

    2013-01-01

    Introduction: A cross sectional study was conducted to estimate risk of exposure to lead via tap water ingestion pathway for the population of Seri Kembangan (SK). Methodology: By using purposive sampling method, 100 respondents who fulfilled the inclusive criteria were selected from different housing areas of SK based on geographical population distribution. Residents with filtration systems installed were excluded from the study. Questionnaires were administered to determine water consumption-related information and demographics. Two water samples (first-flushed and fully-flushed samples) were collected from kitchen tap of each household using HDPE bottles. A total of 200 water samples were collected and lead concentrations were determined using a Graphite Furnace Atomic Absorption Spectrophotometer (GFAAS). Results: Mean lead concentration in first-flushed samples was 3.041± SD 6.967µg/L and 1.064± SD 1.103µg/L for fully-flushed samples. Of the first-flushed samples, four (4) had exceeded the National Drinking Water Quality Standard (NDWQS) lead limit value of 10µg/L while none of the fully-flushed samples had lead concentration exceeded the limit. There was a significant difference between first-flushed samples and fully-flushed samples and flushing had elicited a significant change in lead concentration in the water (Z = -5.880, p<0.05). It was also found that lead concentration in both first-flushed and fully flushed samples was not significantly different across nine (9) areas of Seri Kembangan (p>0.05). Serdang Jaya was found to have the highest lead concentration in first-flushed water (mean= 10.44± SD 17.83µg/L) while Taman Universiti Indah had the highest lead concentration in fully-flushed water (mean=1.45± SD 1.83µg/L). Exposure assessment found that the mean chronic daily intake (CDI) was 0.028± SD 0.034µgday-1kg-1. None of the hazard quotient (HQ) value was found to be greater than 1. Conclusion: The overall quality of water supply in SK was satisfactory because most of the parameters tested in this study were within the range of permissible limit and only a few samples had exceeded the standard values for lead and pH. Non-carcinogenic risk attributed to ingestion of lead in SK tap water was found to be negligible. PMID:23445691

  10. Risk assessment of exposure to lead in tap water among residents of Seri Kembangan, Selangor state, Malaysia.

    PubMed

    Lim, C S; Shaharuddin, M S; Sam, W Y

    2012-11-21

    A cross sectional study was conducted to estimate risk of exposure to lead via tap water ingestion pathway for the population of Seri Kembangan (SK). By using purposive sampling method, 100 respondents who fulfilled the inclusive criteria were selected from different housing areas of SK based on geographical population distribution. Residents with filtration systems installed were excluded from the study. Questionnaires were administered to determine water consumption-related information and demographics. Two water samples (first-flushed and fully-flushed samples) were collected from kitchen tap of each household using HDPE bottles. A total of 200 water samples were collected and lead concentrations were determined using a Graphite Furnace Atomic Absorption Spectrophotometer (GFAAS). Mean lead concentration in first-flushed samples was 3.041± SD 6.967µg/L and 1.064± SD 1.103µg/L for fully-flushed samples. Of the first-flushed samples, four (4) had exceeded the National Drinking Water Quality Standard (NDWQS) lead limit value of 10µg/L while none of the fully-flushed samples had lead concentration exceeded the limit. There was a significant difference between first-flushed samples and fully-flushed samples and flushing had elicited a significant change in lead concentration in the water (Z = -5.880, p<0.05). It was also found that lead concentration in both first-flushed and fully flushed samples was not significantly different across nine (9) areas of Seri Kembangan (p>0.05). Serdang Jaya was found to have the highest lead concentration in first-flushed water (mean= 10.44± SD 17.83µg/L) while Taman Universiti Indah had the highest lead concentration in fully-flushed water (mean=1.45± SD 1.83µg/L). Exposure assessment found that the mean chronic daily intake (CDI) was 0.028± SD 0.034µgday-1kg-1. None of the hazard quotient (HQ) value was found to be greater than 1. The overall quality of water supply in SK was satisfactory because most of the parameters tested in this study were within the range of permissible limit and only a few samples had exceeded the standard values for lead and pH. Non-carcinogenic risk attributed to ingestion of lead in SK tap water was found to be negligible.

  11. Optimization of adenovirus 40 and 41 recovery from tap water using small disk filters.

    PubMed

    McMinn, Brian R

    2013-11-01

    Currently, the U.S. Environmental Protection Agency's Information Collection Rule (ICR) for the primary concentration of viruses from drinking and surface waters uses the 1MDS filter, but a more cost effective option, the NanoCeram® filter, has been shown to recover comparable levels of enterovirus and norovirus from both matrices. In order to achieve the highest viral recoveries, filtration methods require the identification of optimal concentration conditions that are unique for each virus type. This study evaluated the effectiveness of 1MDS and NanoCeram filters in recovering adenovirus (AdV) 40 and 41 from tap water, and optimized two secondary concentration procedures the celite and organic flocculation method. Adjustments in pH were made to both virus elution solutions and sample matrices to determine which resulted in higher virus recovery. Samples were analyzed by quantitative PCR (qPCR) and Most Probable Number (MPN) techniques and AdV recoveries were determined by comparing levels of virus in sample concentrates to that in the initial input. The recovery of adenovirus was highest for samples in unconditioned tap water (pH 8) using the 1MDS filter and celite for secondary concentration. Elution buffer containing 0.1% sodium polyphosphate at pH 10.0 was determined to be most effective overall for both AdV types. Under these conditions, the average recovery for AdV40 and 41 was 49% and 60%, respectively. By optimizing secondary elution steps, AdV recovery from tap water could be improved at least two-fold compared to the currently used methodology. Identification of the optimal concentration conditions for human AdV (HAdV) is important for timely and sensitive detection of these viruses from both surface and drinking waters. Published by Elsevier B.V.

  12. [Investigation of a norovirus outbreak through contaminated centralized water supply system].

    PubMed

    Zheng, Hui-Zhen; Guo, Ru-Ning; Li, Jian-Sen; Zhang, Zheng-Min; Li, Hui

    2009-07-01

    To investigate the etiology and source of an infectious diarrhea outbreak and control the epidemic. Through the retrospective cohort study, we had surveyed all the residents who complained symptoms of diarrhea or vomiting since Nov. 20th,2007 from the five villages in the north of town Y, and collected hygiene information on the water supply system of the five villages, the environment information of three villages and hygiene information of some case-indexed families, and tested the etiological biomarker, including nucleoside acid of norovirus through Real-time PCR and nested PCR technologies. From Nov. 24th to Dec. 3th in 2007, 435 diarrhea or vomiting cases were found in the north of Y town, where tap water A was supplied for daily use. The attack rate was 12.93%. The diarrhea cases were distributed among all country groups who has used tap water A and the attack rate was ranged from 5.21% (20/384) to 21.23% (100/471). Drinking the tap water A was significantly associated with an increased risk of infection (RR = 9.246, 95% CI: 6.25 -13.68). About 85.9% (262/ 305) of the cases were from Nov. 25th to 27th. An investigation of a country of S2 group showed that the incidence of different age groups was distributed as the following: 0 - year-old 20.0% (3/15); 10 - year-old 17.3% (9/52); 20 - year-old 15.2% (16/105); older than 60 year-old 23.3% (7/30). No statistical significance was identified between age and infection(chi2 = 1.15, P >0.05). Most of the patients were not serious and well prognostic, and no hospitalized or dead cases were reported. On site investigation and daily water quality monitoring showed that disinfection procedures were not strictly followed. The monitoring data also indicated the bacteriology index of tap water A was disqualified. The test of Salmonella, Shigella and Staphylococcus aureus were negative in two vomit and one stool samples from patients. Three specimens by Real-time PCR, and six by nested PCR were positive for norovirus among the three feces and three anal swabs samples. With the drinking water sterilization and health education, the epidemic had been controlled rapidly and effectively. The epidemic was a diarrhea outbreak that might be caused by norovirus through drinking the contaminated tap water A.

  13. The Technical Assistance Program: A Program Plan.

    DTIC Science & Technology

    1985-09-01

    interests, talents, and hobbies of current employees who wish to become involved in the technical assistance program . 4. Capitalize on the corporate...Center San Diego, CA 92152 Telephone (619) 225-6281 B-33 TAP ( EMPLOYEE ) QUESTIONNAIRE - The Technical Assistance Program (TAP) links technically skilled...Brochure, "Retired Technologist" C-11 C. Sample Letter to NOSC Employees C-13 Brochure D. The Technical Assistance Program C-15 C-1

  14. 49 CFR 192.150 - Passage of internal inspection devices.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... devices; or (ii) If the design includes taps for lateral connections, the operator can demonstrate, based... circumstances to the use of a tap that will obstruct the passage of instrumented internal inspection devices...

  15. Occurrence of cardiovascular drugs in the sewage-impacted Vistula River and in tap water in the Warsaw region (Poland).

    PubMed

    Giebułtowicz, Joanna; Stankiewicz, Albert; Wroczyński, Piotr; Nałęcz-Jawecki, Grzegorz

    2016-12-01

    In recent years, cardiovascular diseases were the second most common cause of death worldwide. Therefore, the consumption of drugs used to treat cardiovascular diseases is high. So far, there were no such comprehensive reports regarding the presence of cardiovascular drugs in surface and tap waters, particularly in Central and Eastern Europe. The aim of our study was to determine the presence of 30 pharmaceutically active compounds and some of their metabolites, at specific points of the Vistula River and in tap water samples in the Warsaw region. The analysis was performed using the liquid chromatography-electrospray ionization-tandem mass spectrometry method, coupled to solid-phase extraction. To the best of the authors' knowledge, this is the first time where the presence of ciprofibrate in the environment was investigated. Cardiovascular drugs found at the highest concentrations (reaching 1 μg/L or higher) in surface water were beta-blockers, sartans and diuretics. In tap water samples, trace amounts of pharmaceuticals were detected, for almost all target compounds. This highlights their inadequate elimination by the treatment facility used in the Warsaw region. The presence of cardiovascular compounds in the aquatic environment could have a long-term effect even at a low exposure level, since synergy effects amongst pharmaceuticals may occur.

  16. The Application of New Molecular Methods in the Investigation of a Waterborne Outbreak of Norovirus in Denmark, 2012

    PubMed Central

    Schultz, Anna Charlotte; Fonager, Jannik; Ethelberg, Steen; Dalgaard, Camilla; Adelhardt, Marianne; Engberg, Jørgen H.; Fischer, Thea Kølsen; Lassen, Sofie Gillesberg

    2014-01-01

    In December 2012, an outbreak of acute gastrointestinal illness occurred in a geographical distinct area in Denmark covering 368 households. A combined microbiological, epidemiological and environmental investigation was initiated to understand the outbreak magnitude, pathogen(s) and vehicle in order to control the outbreak. Norovirus GII.4 New Orleans 2009 variant was detected in 15 of 17 individual stool samples from 14 households. Norovirus genomic material from water samples was detected and quantified and sequencing of longer parts of the viral capsid region (>1000 nt) were applied to patient and water samples. All five purposely selected water samples tested positive for norovirus GII in levels up to 1.8×104 genomic units per 200 ml. Identical norovirus sequences were found in all 5 sequenced stool samples and 1 sequenced water sample, a second sequenced water sample showed 1 nt (<0.1%) difference. In a cohort study, including 256 participants, cases were defined as residents of the area experiencing diarrhoea or vomiting onset on 12–14 December 2012. We found an attack rate of 51%. Being a case was associated with drinking tap-water on 12–13 December (relative risk = 6.0, 95%CI: 1.6–22) and a dose-response relation for the mean glasses of tap-water consumed was observed. Environmental investigations suggested contamination from a sewage pipe to the drinking water due to fall in pressure during water supply system renovations. The combined microbiological, epidemiological and environmental investigations strongly indicates the outbreak was caused by norovirus contamination of the water supply system. PMID:25222495

  17. Randomised controlled trial of thermostatic mixer valves in reducing bath hot tap water temperature in families with young children in social housing: A protocol

    PubMed Central

    Kendrick, Denise; Stewart, Jane; Coupland, Carol; Hayes, Michael; Hopkins, Nick; McCabe, Debbie; Murphy, Robert; O'Donnell, George; Phillips, Ceri; Radford, David; Ryan, Jackie; Smith, Sherie; Groom, Lindsay; Towner, Elizabeth

    2008-01-01

    Background Each year in the UK 2000 children attend emergency departments and 500 are admitted to hospital following a bath water scald. The long term effects can include disability, disfigurement or psychological harm and repeated skin grafts may be required as the child grows. The costs of treating a severe scald are estimated at 250,000 GBP. Children living in the most deprived wards are at greatest risk of thermal injuries; hospital admission rates are three times that for children living in the least deprived wards. Domestic hot water, which is usually stored at around 60 degrees Celsius, can result in a second-degree burn after 3 seconds and a third-degree burn after 5 seconds. Educational strategies to encourage testing of tap water temperature and reduction of hot water thermostat settings have largely proved unsuccessful. Legislation in the USA mandating pre-setting hot water heater thermostats at 49 degrees Celsius was effective in reducing scald injuries, suggesting passive measures may have a greater impact. Thermostatic mixer valves (TMVs), recently developed for the domestic market, fitted across the hot and cold water supply pipes of the bath, allow delivery of water set at a fixed temperature from the hot bath tap. These valves therefore offer the potential to reduce scald injuries. Design/Methods A pragmatic, randomised controlled trial to assess the effectiveness of TMVs in reducing bath hot tap water temperatures in the homes of families with young children in rented social housing. Two parallel arms include an intervention group and a control group where the intervention will be deferred. The intervention will consist of fitting a TMV (set at 44 degrees Celsius) by a qualified plumber and provision of educational materials. The control arm will not receive a TMV or the educational materials for the study duration but will be offered the intervention after collection of follow-up data 12 months post randomisation. The primary outcome measure will be the bath hot tap water temperature. Fifteen families per arm are required to detect a reduction in the mean bath hot tap water temperature from 60.4 degrees Celsius (SD 9.1) in the control group to 46 degrees Celsius in the intervention group, with 90% power and a 5% significance level (2 sided). Secondary outcome measures including acceptability will require a sample size of 120 participants. Discussion Whilst TMVs have the potential to reduce scald injuries, to date there have been no randomised controlled trials assessing their effectiveness, acceptability and cost effectiveness. Trial Registration ISRCTN21179067 PMID:18348736

  18. NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR METALS IN REPLICATE SAMPLES

    EPA Science Inventory

    The Metals in Replicate Samples data set contains the analytical results of measurements of up to 27 metals in 133 replicate (duplicate) samples from 62 households. Measurements were made in samples of soil, blood, tap water, and drinking water. Duplicate samples for a small pe...

  19. Hematological characteristics in neonates with twin anemia-polycythemia sequence (TAPS).

    PubMed

    Lopriore, E; Slaghekke, F; Oepkes, D; Middeldorp, J M; Vandenbussche, F P H A; Walther, F J

    2010-03-01

    To evaluate the neonatal hematological features of monochorionic twins with twin anemia-polycythemia sequence (TAPS) and to determine the additional diagnostic value of reticulocyte count measurement. A cohort of consecutive monochorionic twins with TAPS (n = 19) was included in the study and each twin pair was compared with two monochorionic twin pairs (n = 38) unaffected by TAPS or twin-twin transfusion syndrome (TTTS), matched for gestational age at birth. We measured full blood counts on day 1 and determined the incidence of anemia, polycythemia, reticulocytosis and thrombocytopenia. Median inter-twin hemoglobin (Hb) difference in monochorionic twins with and without TAPS was 13.7 g/dL and 2.4 g/dL, respectively (p < 0.01). Median inter-twin reticulocyte count ratio in twins with and without TAPS was 3.1 and 1.0, respectively (p < 0.01). Thrombocytopenia (platelet count < 150 x 10(9)/L) occurred more often in the TAPS group than in the control group, 45% (17/38) versus 11% (11/38), respectively (p < 0.01). In the TAPS group, mean platelet count was significantly lower in recipients than in donors, 133 x 10(9)/L versus 218 x 10(9)/L, respectively (p < 0.01). TAPS twins have a large inter-twin Hb difference in combination with a large inter-twin reticulocyte count ratio. Recipients are more often thrombocytopenic than donors, probably due to polycythemia. Copyright (c) 2010 John Wiley & Sons, Ltd.

  20. Finger tapping and pre-attentive sensorimotor timing in adults with ADHD.

    PubMed

    Hove, Michael J; Gravel, Nickolas; Spencer, Rebecca M C; Valera, Eve M

    2017-12-01

    Sensorimotor timing deficits are considered central to attention-deficit/hyperactivity disorder (ADHD). However, the tasks establishing timing impairments often involve interconnected processes, including low-level sensorimotor timing and higher level executive processes such as attention. Thus, the source of timing deficits in ADHD remains unclear. Low-level sensorimotor timing can be isolated from higher level processes in a finger-tapping task that examines the motor response to unexpected shifts of metronome onsets. In this study, adults with ADHD and ADHD-like symptoms (n = 25) and controls (n = 26) performed two finger-tapping tasks. The first assessed tapping variability in a standard tapping task (metronome-paced and unpaced). In the other task, participants tapped along with a metronome that contained unexpected shifts (±15, 50 ms); the timing adjustment on the tap following the shift captures pre-attentive sensorimotor timing (i.e., phase correction) and thus should be free of potential higher order confounds (e.g., attention). In the standard tapping task, as expected, the ADHD group had higher timing variability in both paced and unpaced tappings. However, in the pre-attentive task, performance did not differ between the ADHD and control groups. Together, results suggest that low-level sensorimotor timing and phase correction are largely preserved in ADHD and that some timing impairments observed in ADHD may stem from higher level factors (such as sustained attention).

  1. Exposure of children to metals via tap water ingestion at home: Contamination and exposure data from a nationwide survey in France.

    PubMed

    Le Bot, Barbara; Lucas, Jean-Paul; Lacroix, Françoise; Glorennec, Philippe

    2016-09-01

    29 inorganic compounds (Al, As, B, Ba, Be, Bi, Ca, Cd, Ce, Co, Cr, Cu, Fe, Gd, K, Mg, Mn, Mo, Na, Nd, Ni, Pb, Sb, Se, Sr, Tl, U, V and Zn) were measured in the tap water of 484 representative homes of children aged 6months to 6years in metropolitan France in 2008-2009. Parents were asked whether their children consumed tap water. Sampling design and sampling weights were taken into account to estimate element concentrations in tap water supplied to the 3,581,991 homes of 4,923,058 children aged 6months to 6years. Median and 95th percentiles of concentrations in tap water were in μg/L: Al: <10, 48.3, As: 0.2, 2.1; B: <100, 100; Ba: 30.7, 149.4; Ca: 85,000, 121,700; Cd: <0.5, <0.5; Ce: <0.5, <0.5; Co: <0.5, 0.8; Cr: <5, <5; Cu: 70, 720; K: 2210, 6740; Fe: <20, 46; Mn: <5, <5; Mo: <0.5, 1.5; Na: 14,500, 66,800; Ni: <2, 10.2; Mg: 6500, 21,200; Pb: <1, 5.4; Sb: <0.5, <0.5; Se: <1, 6.7; Sr: 256.9, 1004; Tl: <0.5, <0.5; U: <0.5, 2.4; V: <1, 1; Zn: 53, 208. Of the 2,977,123 young children drinking tap water in France, some were drinking water having concentrations above the 2011 World Health Organization drinking-water quality guidelines: respectively 498 (CI 95%: 0-1484) over 700μg/L of Ba; 121,581 (CI 95%: 7091-236,070) over 50mg/L of Na; 2044 (CI 95%: 0-6132) over 70μg/L of Ni, and 78,466 (17,171-139,761) over 10μg/L of Pb. Since it is representative, this tap water contamination data can be used for integrated exposure assessment, in conjunction with diet and environmental (dust and soil) exposure data. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Occurrence of nitrosamines and their precursors in drinking water systems around mainland China.

    PubMed

    Bei, Er; Shu, Yuanyuan; Li, Shixiang; Liao, Xiaobin; Wang, Jun; Zhang, Xiaojian; Chen, Chao; Krasner, Stuart

    2016-07-01

    N-Nitrosamines (NAs) in drinking water have attracted considerable attention in recent years due to their high carcinogenicity, frequent occurrence, and their potential regulation. During the past three years, we have collected about 164 water samples of finished water, tap water, and source water from 23 provinces, 44 cities from large cities to small towns, and 155 sampling points all over China. The occurrence of NAs in the finished and tap water was much higher in China than that in the U.S. Nine NAs were measured and NDMA had the highest concentration. The occurrence of NDMA was in 33% of the finished waters of water treatment plants and in 41% of the tap waters. The average NDMA concentration in finished and tap waters was 11 and 13 ng/L, respectively. Formation potentials (FPs) of source waters were examined with an average NDMA FP of 66 ng/L. Large variations in NA occurrence were observed geographically in China and temporally in different seasons. The Yangtze River Delta area, one sub-area in East China, had the highest concentrations of NAs, where the average NDMA concentrations in the finished and tap water were 27 and 28.5 ng/L, respectively, and the average NDMA FP in the source water was 204 ng/L. NA control may be achieved by applying breakpoint free chlorination and/or advanced treatment of ozone - granular activated carbon process to remove the NA precursors before disinfection. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Tap water isotope ratios reflect urban water system structure and dynamics across a semiarid metropolitan area

    NASA Astrophysics Data System (ADS)

    Jameel, Yusuf; Brewer, Simon; Good, Stephen P.; Tipple, Brett J.; Ehleringer, James R.; Bowen, Gabriel J.

    2016-08-01

    Water extraction for anthropogenic use has become a major flux in the hydrological cycle. With increasing demand for water and challenges supplying it in the face of climate change, there is a pressing need to better understand connections between human populations, climate, water extraction, water use, and its impacts. To understand these connections, we collected and analyzed stable isotopic ratios of more than 800 urban tap water samples in a series of semiannual water surveys (spring and fall, 2013-2015) across the Salt Lake Valley (SLV) of northern Utah. Consistent with previous work, we found that mean tap water had a lower 2H and 18O concentration than local precipitation, highlighting the importance of nearby montane winter precipitation as source water for the region. However, we observed strong and structured spatiotemporal variation in tap water isotopic compositions across the region which we attribute to complex distribution systems, varying water management practices and multiple sources used across the valley. Water from different sources was not used uniformly throughout the area and we identified significant correlation between water source and demographic parameters including population and income. Isotopic mass balance indicated significant interannual and intra-annual variability in water losses within the distribution network due to evaporation from surface water resources supplying the SLV. Our results demonstrate the effectiveness of isotopes as an indicator of water management strategies and climate impacts within regional urban water systems, with potential utility for monitoring, regulation, forensic, and a range of water resource research.

  4. A phase III, open-label, randomised multicentre study to evaluate the immunogenicity and safety of a booster dose of two different reduced antigen diphtheria-tetanus-acellular pertussis-polio vaccines, when co-administered with measles-mumps-rubella vaccine in 3 and 4-year-old healthy children in the UK.

    PubMed

    Marlow, Robin; Kuriyakose, Sherine; Mesaros, Narcisa; Han, Htay Htay; Tomlinson, Richard; Faust, Saul N; Snape, Matthew D; Pollard, Andrew J; Finn, Adam

    2018-04-19

    To evaluate the immunogenicity and safety of a reduced antigen diphtheria-tetanus-acellular pertussis-inactivated poliovirus (dTap-IPV B ) vaccine (Boostrix-IPV, GSK) as a pre-school booster in 3-4 year old children as compared to dTap-IPV R (Repevax, Sanofi Pasteur), when co-administered with mumps-measles-rubella vaccine (MMRV). This phase III, open label, randomised study was conducted in the UK between April 2011 and April 2012. Children due their pre-school dTap-IPV booster vaccination were randomised 2:1 to receive one of two different dTap-IPV vaccines (dTap-IPV B or dTap-IPV R ) with blood sample for immunogenicity assessment just prior and one month after vaccination. Immune responses to diphtheria, tetanus and polio antigens were compared between the study vaccines (inferential comparison). In the absence of an accepted pertussis correlate of protection, the immunogenicity of dTap-IPV B vaccine against pertussis was compared with historical pertussis efficacy data (inferential comparison). Safety and reactogenicity of both study vaccines were evaluated. 387 children were randomised and 385 vaccinated: 255 in the dTap-IPV B group and 130 in the dTap-IPV R group. Prior to vaccination, ≥76.8% of children had anti-diphtheria and ≥65.5% had anti-tetanus titres above the protection threshold; for pertussis, the pre-vaccination seropositivity rate ranged between 18.1 and 70.6%. Both vaccines were immunogenic with 99.2-100% of children achieving titres above the pre-specified seroprotection/seropositivity thresholds. One serious adverse event not considered as causally related to the study vaccination by the study investigator was reported in the dTap-IPV B group. Non-inferiority of dTap-IPV B to dTap-IPV R was demonstrated. Both vaccines had a clinically acceptable safety and reactogenicity profile when co-administered with MMRV to children 3-4 years old. NCT01245049 (ClinicalTrials.gov). Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  5. Getting the lead out: understanding risks in the distribution ...

    EPA Pesticide Factsheets

    This presentation discusses the importance of the water distribution system as a component of the source-to-tap continuum in public health protection. Issues covered include: understanding source water quality changes and their impacts throughout the system; use of mitigation measures such as filters); and holistic approaches and/or strategies that could be used to avoid unintended consequences of decisions from source to tap. Invited presentation on topics indicated as of interest. With exposure to lead as the context, this presentation discusses the importance of the water distribution system as a component of the source-to-tap continuum in public health protection. Issues covered include: understanding source water quality changes and their impacts throughout the system; use of mitigation measures such as filters); and holistic approaches and/or strategies that could be used to avoid unintended consequences of decisions from source to tap.

  6. Mechanical sieve for screening mineral samples

    NASA Technical Reports Server (NTRS)

    Otto, W. P.

    1970-01-01

    Mechanical sieve consists of three horizontal screens mounted in a vertical stack. A combination of rotation and tapping produces an even flow across the screens, dislodges trapped particles, an ensures rapid segregation of the sample.

  7. Contamination of faecal coliforms in ice cubes sampled from food outlets in Kubang Kerian, Kelantan.

    PubMed

    Noor Izani, N J; Zulaikha, A R; Mohamad Noor, M R; Amri, M A; Mahat, N A

    2012-03-01

    The use of ice cubes in beverages is common among patrons of food outlets in Malaysia although its safety for human consumption remains unclear. Hence, this study was designed to determine the presence of faecal coliforms and several useful water physicochemical parameters viz. free residual chlorine concentration, turbidity and pH in ice cubes from 30 randomly selected food outlets in Kubang Kerian, Kelantan. Faecal coliforms were found in ice cubes in 16 (53%) food outlets ranging between 1 CFU/100mL to >50 CFU/ 100mL, while in the remaining 14 (47%) food outlets, in samples of tap water as well as in commercially bottled drinking water, faecal coliforms were not detected. The highest faecal coliform counts of >50 CFU/100mL were observed in 3 (10%) food outlets followed by 11-50 CFU/100mL and 1-10 CFU/100mL in 7 (23%) and 6 (20%) food outlets, respectively. All samples recorded low free residual chlorine concentration (<0.10mg/L) with the pH ranging between 5.5 and 7.3 and turbidity between 0.14-1.76 NTU. Since contamination by faecal coliforms was not detected in 47% of the samples, tap water and commercially bottled drinking water, it was concluded that (1) contamination by faecal coliforms may occur due to improper handling of ice cubes at the food outlets or (2) they may not be the water sources used for making ice cubes. Since low free residual chlorine concentrations were observed (<0.10mg/ L) in all samples as well as in both tap water and commercially bottled drinking water, with the pH ranged between 5.5-7.3, ineffective disinfection of water source as a contributing factor to such high counts of faecal coliforms in ice cubes also could not be ruled out. Therefore, a periodical, yet comprehensive check on the food outlets, including that of ice cube is crucial in ensuring better food and water for human consumption.

  8. Interactional synchrony in chimpanzees: Examination through a finger-tapping experiment.

    PubMed

    Yu, Lira; Tomonaga, Masaki

    2015-05-11

    Humans often unconsciously coordinate behaviour with that of others in daily life. This interpersonal coordination, including mimicry and interactional synchrony, has been suggested to play a fundamental role in social interaction. If this coordinative behavior is socially adaptive, it may be shared with other highly social animal species. The current study targeted chimpanzees, which phylogenetically are the closest living relatives of humans and live in complex social groups, and examined whether interactional synchrony would emerge in pairs of chimpanzees when auditory information about a partner's movement was provided. A finger-tapping task was introduced via touch panels to elicit repetitive and rhythmic movement from each chimpanzee. We found that one of four chimpanzees produced significant changes in both tapping tempo and timing of the tapping relative to its partner's tap when auditory sounds were provided. Although the current results may have limitations in generalizing to chimpanzees as a species, we suggest that a finger-tapping task is one potential method to investigate interactional synchrony in chimpanzees under a laboratory setup.

  9. 40 CFR 141.703 - Sampling locations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 23 2011-07-01 2011-07-01 false Sampling locations. 141.703 Section... Monitoring Requirements § 141.703 Sampling locations. (a) Systems required to conduct source water monitoring... a sampling tap is available where the sources are combined prior to treatment, systems must collect...

  10. Determination of physicochemical properties and degradation kinetics of triamcinolone acetonide palmitate in vitro.

    PubMed

    Peng, Cuilian; Liu, Cong; Tang, Xing

    2010-12-01

    Triamcinolone acetonide palmitate (TAP) is a lipophilic prodrug of triamcinolone acetonide (TAA) to improve the insoluble TAA physicochemical properties for the preparation of emulsions. This investigation has focused on the preformulation study of TAP, including its physicochemical properties and hydrolysis kinetics in vitro. The solubility of TAP in medium-chain triglyceride is about twice greater than that in soybean oil (long-chain triglyceride) (19.17 versus 9.55 mg/g) at 25°C, and in all investigated cases, lecithin (80, 160, and 240 mg/g) as solubilizer provided increased solubility of drugs in medium-chain triglyceride and long-chain triglyceride, whereas the maximum water solubility of TAP was 0.10 μg/mL. The partition coefficient (log P) of TAP was 5.79 irrespective of the pH conditions. The hydrolysis of TAP followed pseudo-first-order kinetics in aqueous solutions, and the stable pH range was from pH 5.0 to 9.0. The in vitro enzymolysis kinetics of TAP in rat plasma and liver homogenate was evaluated by measuring the decrease of TAP as well as the increase of TAA at 37°C for 96 hours. The results demonstrated that the TAP may be hydrolyzed mainly by rat plasma esterase and, to a minor extent, by liver esterase, and the hydrolysis half-life of TAP in 100% rat plasma was 17.53 ± 6.85 hours at pH 7.4. All these results indicated that TAP had successfully obtained higher lipid-soluble property for the preparation of intravenous emulsion and may be an effective prodrug for sustained release of TAA in vivo.

  11. Estimating the Effects of the Terminal Area Productivity Program

    NASA Technical Reports Server (NTRS)

    Lee, David A.; Kostiuk, Peter F.; Hemm, Robert V., Jr.; Wingrove, Earl R., III; Shapiro, Gerald

    1997-01-01

    The report describes methods and results of an analysis of the technical and economic benefits of the systems to be developed in the NASA Terminal Area Productivity (TAP) program. A runway capacity model using parameters that reflect the potential impact of the TAP technologies is described. The runway capacity model feeds airport specific models which are also described. The capacity estimates are used with a queuing model to calculate aircraft delays, and TAP benefits are determined by calculating the savings due to reduced delays. The report includes benefit estimates for Boston Logan and Detroit Wayne County airports. An appendix includes a description and listing of the runway capacity model.

  12. Exposure assessment of radon in the drinking water supplies: a descriptive study in Palestine

    PubMed Central

    2012-01-01

    Background Radon gas is considered as a main risk factor for lung cancer and found naturally in rock, soil, and water. The objective of this study was to determine the radon level in the drinking water sources in Nablus city in order to set up a sound policy on water management in Palestine. Methods This was a descriptive study carried out in two phases with a random sampling technique in the second phase. Primarily, samples were taken from 4 wells and 5 springs that supplied Nablus city residents. For each source, 3 samples were taken and each was analyzed in 4 cycles by RAD 7 device manufactured by Durridge Company. Secondly, from the seven regions of the Nablus city, three samples were taken from the residential tap water of each region. Regarding the old city, ten samples were taken. Finally, the mean radon concentration value for each source was calculated. Results The mean (range) concentration of radon in the main sources were 6.9 (1.5-23.4) Becquerel/liter (Bq/L). Separately, springs and wells' means were 4.6 Bq/L and 9.5 Bq/L; respectively. For the residential tap water in the 7 regions, the results of the mean (range) concentration values were found to be 1.0 (0.9-1.3) Bq/L. For the old city, the mean (range) concentration values were 2.3 (0.9-3.9) Bq/L. Conclusions Except for Al-Badan well, radon concentrations in the wells and springs were below the United State Environmental Protection Agency maximum contaminated level (U.S EPA MCL). The level was much lower for tap water. Although the concentration of radon in the tap water of old city were below the MCL, it was higher than other regions in the city. Preventive measures and population awareness on radon's exposure are recommended. PMID:22243625

  13. Exposure assessment of radon in the drinking water supplies: a descriptive study in Palestine.

    PubMed

    Al Zabadi, Hamzeh; Musmar, Samar; Issa, Shaza; Dwaikat, Nidal; Saffarini, Ghassan

    2012-01-13

    Radon gas is considered as a main risk factor for lung cancer and found naturally in rock, soil, and water. The objective of this study was to determine the radon level in the drinking water sources in Nablus city in order to set up a sound policy on water management in Palestine. This was a descriptive study carried out in two phases with a random sampling technique in the second phase. Primarily, samples were taken from 4 wells and 5 springs that supplied Nablus city residents. For each source, 3 samples were taken and each was analyzed in 4 cycles by RAD 7 device manufactured by Durridge Company. Secondly, from the seven regions of the Nablus city, three samples were taken from the residential tap water of each region. Regarding the old city, ten samples were taken. Finally, the mean radon concentration value for each source was calculated. The mean (range) concentration of radon in the main sources were 6.9 (1.5-23.4) Becquerel/liter (Bq/L). Separately, springs and wells' means were 4.6 Bq/L and 9.5 Bq/L; respectively. For the residential tap water in the 7 regions, the results of the mean (range) concentration values were found to be 1.0 (0.9-1.3) Bq/L. For the old city, the mean (range) concentration values were 2.3 (0.9-3.9) Bq/L. Except for Al-Badan well, radon concentrations in the wells and springs were below the United State Environmental Protection Agency maximum contaminated level (U.S EPA MCL). The level was much lower for tap water. Although the concentration of radon in the tap water of old city were below the MCL, it was higher than other regions in the city. Preventive measures and population awareness on radon's exposure are recommended.

  14. Drinking Water Management: Health Risk Perceptions and Choices in First Nations and Non-First Nations Communities in Canada

    PubMed Central

    Dupont, Diane; Waldner, Cheryl; Bharadwaj, Lalita; Plummer, Ryan; Carter, Blair; Cave, Kate; Zagozewski, Rebecca

    2014-01-01

    The relationship between tap water and health has been a topic of public concern and calls for better management in Canada since well-publicized contamination events in two provinces (Ontario and Saskatchewan) in 2000–2001. This study reports the perspectives on health risks from tap water and corresponding use of, and spending on, bottled water in a number of different communities in Canada. In 2009–2010, four First Nations communities (three from Ontario and one from Saskatchewan) and a geographically diverse sample of non-First Nations Canadians were surveyed about their beliefs concerning health risks from tap water and their spending practices for bottled water as a substitute. Responses to five identical questions were examined, revealing that survey respondents from Ontario First Nations communities were more likely than non-First Nations Canadians to believe bottled water is safer than tap water (OR 1.6); more likely to report someone became ill from tap water (OR 3.6); more likely to express water and health concerns related to tap water consumption (OR 2.4); and more likely to spend more on bottled water (OR 4.9). On the other hand, participants from one Saskatchewan First Nations community were less likely than non-First Nations Canadians to believe that someone had become ill from drinking tap water (OR 3.8), less likely to believe bottled water is safer than tap (OR 2.0), and less likely to have health concerns with tap water (OR 1.5). These differences, however, did not translate into differences in the likelihood of high bottled water expenditures or being a 100% bottled water consumer. The paper discusses how the differences observed may be related to water supply and regulation, trust, perceived control, cultural background, location, and past experience. PMID:24886757

  15. Application of NaClO-treated multiwalled carbon nanotubes as solid phase extraction sorbents for preconcentration of trace 2,4-dichlorophenoxyacetic acid in aqueous samples.

    PubMed

    Lu, Ping; Deng, Dayi; Ni, Xiaodan

    2012-09-01

    Multiwalled carbon nanotubes functionalized by oxidation of original multiwalled carbon nanotubes with NaClO were prepared and their application as solid phase extraction sorbent for 2,4-dichlorophenoxyacetic acid (2,4-D) was investigated systemically, and a new method was developed for the determination of trace 2,4-D in water samples based on extraction and preconcentration of 2,4-D with solid phase extraction columns packed with NaClO-treated multiwalled carbon nanotubes prior to its determination by HPLC. The optimum experimental parameters for preconcentration of 2,4-D, including the column activating conditions, the amount of the sorbent, pH of the sample, elution composition, and elution volume, were investigated. The results indicated 2,4-D could be quantitatively retained by 100 mg NaClO-treated multiwalled carbon nanotubes at pH 5, and then eluted completely with 10 mL 3:1 (v/v) methanol-ammonium acetate solution (0.3 mol/L). The detection limit of this method for 2,4-D was 0.15 μg/L, and the relative standard deviation was 2.3% for fortified tap water samples and 2.5% for fortified riverine water sample at the 10 μg/L level. The method was validated using fortified tap water and riverine water samples with known amount of 2,4-D at the 0.4, 10, and 30 μg/L levels, respectively. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Prevalence of pathogenic free-living amoeba and other protozoa in natural and communal piped tap water from Queen Elizabeth protected area, Uganda.

    PubMed

    Sente, Celsus; Erume, Joseph; Naigaga, Irene; Mulindwa, Julius; Ochwo, Sylvester; Magambo, Phillip Kimuda; Namara, Benigna Gabriela; Kato, Charles Drago; Sebyatika, George; Muwonge, Kevin; Ocaido, Michael

    2016-08-03

    Pathogenic water dwelling protozoa such as Acanthamoeba spp., Hartmannella spp., Naegleria spp., Cryptosporidium spp. and Giardia spp. are often responsible for devastating illnesses especially in children and immunocompromised individuals, yet their presence and prevalence in certain environment in sub-Saharan Africa is still unknown to most researchers, public health officials and medical practitioners. The objective of this study was to establish the presence and prevalence of pathogenic free-living amoeba (FLA), Cryptosporidium and Giardia in Queen Elizabeth Protected Area (QEPA). Samples were collected from communal taps and natural water sites in QEPA. Physical water parameters were measured in situ. The samples were processed to detect the presence of FLA trophozoites by xenic cultivation, Cryptosporidium oocysts by Ziehl-Neelsen stain and Giardia cysts by Zinc Sulphate floatation technique. Parasites were observed microscopically, identified, counted and recorded. For FLA, genomic DNA was extracted for amplification and sequencing. Both natural and tap water sources were contaminated with FLA, Cryptosporidium spp. and Giardia spp. All protozoan parasites were more abundant in the colder rainy season except for Harmannella spp. and Naegleria spp. which occurred more in the warmer months. The prevalence of all parasites was higher in tap water than in natural water samples. There was a strong negative correlation between the presence of Acanthamoeba spp., Hartmannella spp., Cryptosporidium spp. and Giardia spp. with Dissolved Oxygen (DO) (P < 0.05). The presence of Cryptosporidium spp. showed a significant positive correlation (P < 0.05) with conductivity, pH and Total Dissolved Solids (TDS); whereas the presence of Giardia spp. had only a strong positive correlation with TDS. Molecular genotyping of FLA produced 7 Acanthamoeba, 5 Echinamoeba, 2 Hartmannella, 1 Bodomorpha, 1 Nuclearia and 1 Cercomonas partial sequences. All water collection sites were found to be contaminated with pathogenic protozoa that could possibly be the cause of a number of silent morbidities and mortalities among rural households in QEPA. This implies that water used by communities in QEPA is of poor quality and predisposes them to a variety of protozoan infections including the FLA whose public health importance was never reported, thus necessitating adoption of proper water safety measures.

  17. Hydrogeology and quality of ground water in Orange County, Florida

    USGS Publications Warehouse

    Adamski, James C.; German, Edward R.

    2004-01-01

    Ground water is the main source of water supply in central Florida and is critical for aquatic habitats and human consumption. To provide a better understanding for the conservation, development, and management of the water resources of Orange County, Florida, a study of the hydrogeologic framework, water budget, and ground-water quality characteristics was conducted from 1998 through 2002. The study also included extensive analyses of the surface-water resources, published as a separate report. An increase in population from about 264,000 in 1960 to 896,000 in 2000 and subsequent urban growth throughout this region has been accompanied by a substantial increase in water use. Total ground-water use in Orange County increased from about 82 million gallons per day in 1965 to about 287 million gallons per day in 2000. The hydrogeology of Orange County consists of three major hydrogeologic units: the surficial aquifer system, the intermediate confining unit, and the Floridan aquifer system. Data were compiled from 634 sites to construct hydrogeologic maps and sections of Orange County. Water-level elevations measured in 23 wells tapping the surficial aquifer system ranged from about 10.6 feet in eastern Orange County to 123.8 feet above NGVD 29 in northwestern Orange County from March 2000 through September 2001. Water levels also were measured in 14 wells tapping the Upper Floridan aquifer. Water levels fluctuate over time from seasonal and annual variations in rainfall; however, water levels in a number of wells tapping the Upper Floridan aquifer have declined over time. Withdrawal of ground water from the aquifers by pumping probably is causing the declines because the average annual precipitation rate has not changed substantially in central Florida since the 1930s, although yearly rates can vary. A generalized water budget was computed for Orange County from 1991 to 2000. Average rates for the 10-year period for the following budget components were computed based on reported measurements or estimates: precipitation was 53 inches per year (in/yr), runoff was 11 in/yr, spring discharge was 2 in/yr, and net lateral subsurface outflow and exported water was 1 in/yr. Evapotranspiration was 39 in/yr, which was calculated as the residual of the water-budget analysis, assuming changes in storage were negligible. Water-quality samples were collected from April 1999 through May 2001 from a total of 26 wells tapping the surficial aquifer system, 1 well tapping the intermediate confining unit, 24 wells tapping the Upper Floridan aquifer, 2 springs issuing from the Upper Floridan aquifer, and 8 wells tapping the Lower Floridan aquifer. These data were supplemented with existing water-quality data collected by the U.S. Geological Survey and St. Johns River Water Management District. Concentrations of total dissolved solids, sulfate, and chloride in samples from the surficial aquifer system generally were low. Concentrations of nitrate were higher in samples from the surficial aquifer system than in samples from the Upper Floridan or Lower Floridan aquifers, probably as a result of agricultural and residential land use. Water type throughout most of the Upper Floridan and Lower Floridan aquifers was calcium or calcium-magnesium bicarbonate, probably as a result of dissolution of the carbonate rocks. Water type in both the surficial and Floridan aquifer systems in eastern Orange County is sodium chloride. Concentrations of total dissolved solids, sulfate, and chloride in the aquifers increase toward eastern Orange County. Data from 16 of 24 wells in eastern Orange County with long-term water-quality records indicated distinct increases in concentrations of chloride over time. The increases probably are related to withdrawal of ground water at the Cocoa well field, causing an upwelling of deeper, more saline water. The most commonly detected trace elements were aluminum, barium, boron, iron, manganese, and strontium. In addition, arse

  18. Primary stability and self-tapping blades: biomechanical assessment of dental implants in medium-density bone.

    PubMed

    Kim, Yung-Soo; Lim, Young-Jun

    2011-10-01

    The aim of this biomechanical study was to assess the influence of self-tapping blades in terms of primary implant stability between implants with self-tapping blades and implants without self-tapping blades using five different analytic methods, especially in medium-density bone. Two different types of dental implants (4 × 10 mm) were tested: self-tapping and non-self-tapping. The fixture design including thread profiles was exactly the same between the two groups; the only difference was the presence of cutting blades on one half of the apical portion of the implant body. Solid rigid polyurethane blocks with corresponding densities were selected to simulate medium-density bone. Five mechanical assessments (insertion torque, resonance frequency analysis [RFA], reverse torque, pull-out and push in test) were performed for primary stability. Implants without self-tapping blades showed significantly higher values (P<0.001) in four biomechanical assessments, except RFA (P=0.684). However, a statistically significant correlation could not be detected between insertion torque values with the four different outcome variables (P>0.05). The outcomes of the present study indicate that the implant body design without self-tapping blades has a good primary stability compared with that with self-tapping blades in medium-density bone. Considering the RFA, a distinct layer of cortical bone on marginal bone will yield implant stability quotient values similar to those in medium-bone density when implants have the same diameter. © 2011 John Wiley & Sons A/S.

  19. 78 FR 28945 - Open Meeting of the Taxpayer Advocacy Panel Joint Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-16

    ... Gilbert. For more information please contact Ms. Gilbert at 1-888-912-1227 or (515) 564-6638 or write: TAP....improveirs.org . The agenda will include various committee issues for submission to the IRS and other TAP...

  20. TAP into Learning, Fall-Winter 2000.

    ERIC Educational Resources Information Center

    Burns, Mary; Dimock, Vicki; Martinez, Danny

    2000-01-01

    This document consists of the final three issues of "TAP into Learning" (Technology Assistance Program). The double fall issue focuses on knowledge construction and on using multimedia applications in the classroom. Contents include: "Knowledge Under Construction"; "Hegel and the Dialectic"; "Implications for…

  1. Tapping mode imaging with an interfacial force microscope

    NASA Astrophysics Data System (ADS)

    Warren, O. L.; Graham, J. F.; Norton, P. R.

    1997-11-01

    In their present embodiment, sensors used in interfacial force microscopy do not have the necessary mechanical bandwidth to be employed as free-running tapping mode devices. We describe an extremely stable method of obtaining tapping mode images using feedback on the sensor. Our method is immune to small dc drifts in the force signal, and the prospect of diminishing the risk of damaging fragile samples is realized. The feasibility of the technique is demonstrated by our imaging work on a Kevlar fiber-epoxy composite. We also present a model which accounts for the frequency dependence of the sensor in air when operating under closed loop control. A simplified force modulation model is investigated to explore the effect of contact on the closed loop response of the sensor.

  2. Self-Advancing Step-Tap Drills

    NASA Technical Reports Server (NTRS)

    Pettit, Donald R.; Camarda, Charles J.; Penner, Ronald K.; Franklin, Larry D.

    2007-01-01

    Self-advancing tool bits that are hybrids of drills and stepped taps make it possible to form threaded holes wider than about 1/2 in. (about 13 mm) without applying any more axial force than is necessary for forming narrower pilot holes. These self-advancing stepped-tap drills were invented for use by space-suited astronauts performing repairs on reinforced carbon/carbon space-shuttle leading edges during space walks, in which the ability to apply axial drilling forces is severely limited. Self-advancing stepped-tap drills could also be used on Earth for making wide holes without applying large axial forces. A self-advancing stepped-tap drill (see figure) includes several sections having progressively larger diameters, typically in increments between 0.030 and 0.060 in. (between about 0.8 and about 1.5 mm). The tip section, which is the narrowest, is a pilot drill bit that typically has a diameter between 1/8 and 3/16 in. (between about 3.2 and about 4.8 mm). The length of the pilot-drill section is chosen, according to the thickness of the object to be drilled and tapped, so that the pilot hole is completed before engagement of the first tap section. Provided that the cutting-edge geometry of the drill bit is optimized for the material to be drilled, only a relatively small axial force [typically of the order of a few pounds (of the order of 10 newtons)] must be applied during drilling of the pilot hole. Once the first tap section engages the pilot hole, it is no longer necessary for the drill operator to apply axial force: the thread engagement between the tap and the workpiece provides the axial force to advance the tool bit. Like the pilot-drill section, each tap section must be long enough to complete its hole before engagement of the next, slightly wider tap section. The precise values of the increments in diameter, the thread pitch, the rake angle of the tap cutting edge, and other geometric parameters of the tap sections must be chosen, in consideration of the workpiece material and thickness, to prevent stripping of threads during the drilling/tapping operation. A stop-lip or shoulder at the shank end of the widest tap section prevents further passage of the tool bit through the hole.

  3. Study of tapping process of carbon fiber reinforced plastic composites/AA7075 stacks

    NASA Astrophysics Data System (ADS)

    D'Orazio, Alessio; Mehtedi, Mohamad El; Forcellese, Archimede; Nardinocchi, Alessia; Simoncini, Michela

    2018-05-01

    The present investigation aims at studying the tapping process of a three-layer stack constituted by two CFRP layers and a core plate in AA7075 aluminum alloy. The CFRP laminates were obtained by a pre-impregnated woven sample made up of T700 carbon fibers and a thermoset epoxy matrix. Tapping experiments were performed on a 5-axis machining center instrumented with a dynamometer to measure thrust force generated during process. A high-speed steel tool, coated with nanocomposite TiAlN, was used. According to the tool manufacturer recommendations, rotational speed and feed rate were 800 rpm and 1000 mm/min, respectively. Similar thrust force time history responses were obtained by tapping different holes, even though the vertical force increases with number of threaded holes. Furthermore, a quantitative evaluation of delamination at the periphery of entry holes was carried out. The delamination at the entry hole strongly increases with number of threaded holes.

  4. Overnight stagnation of drinking water in household taps induces microbial growth and changes in community composition.

    PubMed

    Lautenschlager, Karin; Boon, Nico; Wang, Yingying; Egli, Thomas; Hammes, Frederik

    2010-09-01

    Drinking water quality is routinely monitored in the distribution network but not inside households at the point of consumption. Fluctuating temperatures, residence times (stagnation), pipe materials and decreasing pipe diameters can promote bacterial growth in buildings. To test the influence of stagnation in households on the bacterial cell concentrations and composition, water was sampled from 10 separate households after overnight stagnation and after flushing the taps. Cell concentrations, measured by flow cytometry, increased (2-3-fold) in all water samples after stagnation. This increase was also observed in adenosine tri-phosphate (ATP) concentrations (2-18-fold) and heterotrophic plate counts (4-580-fold). An observed increase in cell biovolume and ATP-per-cell concentrations furthermore suggests that the increase in cell concentrations was due to microbial growth. After 5 min flushing of the taps, cell concentrations and water temperature decreased to the level generally found in the drinking water network. Denaturing gradient gel electrophoresis also showed a change in the microbial composition after stagnation. This study showed that water stagnation in household pipes results in considerable microbial changes. While hygienic risk was not directly assessed, it emphasizes the need for the development of good material validation methods, recommendations and spot tests for in-house water installations. However, a simple mitigation strategy would be a short flushing of taps prior to use. Copyright © 2010 Elsevier Ltd. All rights reserved.

  5. Contribution of tap water to chlorate and perchlorate intake: a market basket study.

    PubMed

    Asami, Mari; Yoshida, Nobue; Kosaka, Koji; Ohno, Koichi; Matsui, Yoshihiko

    2013-10-01

    The contributions of water to total levels of chlorate and perchlorate intake were determined using food and water samples from a market basket study from 10 locations in Japan between 2008 and 2009. Foods were categorized into 13 groups and analyzed along with tap water. The average total chlorate intake was 333 (min. 193-max. 486) μg/day for samples cooked with tap water. The contribution of tap water to total chlorate intake was as high as 47%-58%, although total chlorate intake was less than 32% of the tolerable daily intake, 1500 μg/day for body weight of 50 kg. For perchlorate, daily intake from water was 0.7 (0.1-4.4) μg/day, which is not high compared to the average total intake of 14 (2.5-84) μg/day, while the reference dose (RfD) is 35 μg/day and the provisional maximum tolerable daily intake (PMTDI) is 500 μg/day for body weight of 50 kg. The highest intake of perchlorate was 84 μg/day, where concentrations in foods were high, but not in water. The contribution of water to total perchlorate intake ranged from 0.5% to 22%, while the ratio of highest daily intake to RfD was 240% and that to PMTDI was 17%. Eight baby formulas were also tested--total chlorate and perchlorate intakes were 147 (42-332) μg/day and 1.11 (0.05-4.5) μg/day, respectively, for an ingestion volume of 1 L/day if prepared with tap water. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Indoor Heating Drives Water Bacterial Growth and Community Metabolic Profile Changes in Building Tap Pipes during the Winter Season

    PubMed Central

    Zhang, Hai-Han; Chen, Sheng-Nan; Huang, Ting-Lin; Shang, Pan-Lu; Yang, Xiao; Ma, Wei-Xing

    2015-01-01

    The growth of the bacterial community harbored in indoor drinking water taps is regulated by external environmental factors, such as indoor temperature. However, the effect of indoor heating on bacterial regrowth associated with indoor drinking water taps is poorly understood. In the present work, flow cytometry and community-level sole-carbon-source utilization techniques were combined to explore the effects of indoor heating on water bacterial cell concentrations and community carbon metabolic profiles in building tap pipes during the winter season. The results showed that the temperature of water stagnated overnight (“before”) in the indoor water pipes was 15–17 °C, and the water temperature decreased to 4–6 °C after flushing for 10 min (“flushed”). The highest bacterial cell number was observed in water stagnated overnight, and was 5–11 times higher than that of flushed water. Meanwhile, a significantly higher bacterial community metabolic activity (AWCD590nm) was also found in overnight stagnation water samples. The significant “flushed” and “taps” values indicated that the AWCD590nm, and bacterial cell number varied among the taps within the flushed group (p < 0.01). Heatmap fingerprints and principle component analyses (PCA) revealed a significant discrimination bacterial community functional metabolic profiles in the water stagnated overnight and flushed water. Serine, threonine, glucose-phosphate, ketobutyric acid, phenylethylamine, glycerol, putrescine were significantly used by “before” water samples. The results suggested that water stagnated at higher temperature should be treated before drinking because of bacterial regrowth. The data from this work provides useful information on reasonable utilization of drinking water after stagnation in indoor pipes during indoor heating periods. PMID:26516885

  7. HUMAN EXPOSURE TO WATER DISINFECTION BY-PRODUCTS VIA FOODS AND BEVERAGES

    EPA Science Inventory

    The ingestion of tap water is a major route of exposure to water disinfection byproducts (DBPs), including haloacetonitriles, haloketones, and haloacetic acids. A potentially significant alternate route of exposure is through the consumption of beverages prepared with tap water ...

  8. Traffic Aware Planner (TAP) Flight Evaluation

    NASA Technical Reports Server (NTRS)

    Maris, John M.; Haynes, Mark A.; Wing, David J.; Burke, Kelly A.; Henderson, Jeff; Woods, Sharon E.

    2014-01-01

    NASA's Traffic Aware Planner (TAP) is a cockpit decision support tool that has the potential to achieve significant fuel and time savings when it is embedded in the data-rich Next Generation Air Transportation System (NextGen) airspace. To address a key step towards the operational deployment of TAP and the NASA concept of Traffic Aware Strategic Aircrew Requests (TASAR), a system evaluation was conducted in a representative flight environment in November, 2013. Numerous challenges were overcome to achieve this goal, including the porting of the foundational Autonomous Operations Planner (AOP) software from its original simulation-based, avionics-embedded environment to an Electronic Flight Bag (EFB) platform. A flight-test aircraft was modified to host the EFB, the TAP application, an Automatic Dependent Surveillance Broadcast (ADS-B) processor, and a satellite broadband datalink. Nine Evaluation Pilots conducted 26 hours of TAP assessments using four route profiles in the complex eastern and north-eastern United States airspace. Extensive avionics and video data were collected, supplemented by comprehensive inflight and post-flight questionnaires. TAP was verified to function properly in the live avionics and ADS-B environment, characterized by recorded data dropouts, latency, and ADS-B message fluctuations. Twelve TAP-generated optimization requests were submitted to ATC, of which nine were approved, and all of which resulted in fuel and/or time savings. Analysis of subjective workload data indicated that pilot interaction with TAP during flight operations did not induce additional cognitive loading. Additionally, analyses of post-flight questionnaire data showed that the pilots perceived TAP to be useful, understandable, intuitive, and easy to use. All program objectives were met, and the next phase of TAP development and evaluations with partner airlines is in planning for 2015.

  9. Effects of preoperative ultrasound-guided transversus abdominis plane block on pain after laparoscopic surgery for colorectal cancer: a double-blind randomized controlled trial.

    PubMed

    Oh, Tak Kyu; Yim, Jiyeon; Kim, Jaehyun; Eom, Woosik; Lee, Soon Ae; Park, Sung Chan; Oh, Jae Hwan; Park, Ji Won; Park, Boram; Kim, Dae Hyun

    2017-01-01

    Although laparoscopic colorectal surgery decreases postoperative pain and facilitates a speedier recovery compared with laparotomy, postoperative pain at trocar insertion sites remains a clinical concern. The objective of this study was to assess the effects of a preoperative ultrasound-guided transversus abdominis plane (TAP) block on pain after laparoscopic surgery for colorectal cancer. In total, 58 patients scheduled to undergo laparoscopic surgery following a diagnosis of colorectal cancer were included in this study. The patients were randomized into TAP and control groups; the TAP group patients received a preoperative ultrasound-guided bilateral TAP block with 0.5 mL/kg of 0.25 % bupivacaine, while the control patients received the block with an equal amount of saline. Pain on coughing and at rest was assessed during postanesthetic recovery (PAR; 1 h after surgery) and on postoperative days (PODs) 1 (24 h), 2 (48 h), and 3 (72 h) by an investigator blinded to group allocations using the numeric rating scale (NRS). The primary outcome was pain on coughing on postoperative day (POD) 1. Fifty-five patients were included in the final analysis, including 28 in the TAP and 27 in the control groups. The pain intensity on coughing and at rest during PAR and on PODs 1, 2, and 3 showed no significant differences between groups. Furthermore, there was no significant difference in postoperative opioid consumption, sedation scores, nausea scores at the four time points, complication rates, and length of hospital stay between groups. In colorectal cancer patients undergoing laparoscopic colorectal surgery, a TAP block did not offer enough benefit for clinical efficacy in terms of postoperative pain or analgesic consumption.

  10. Construction of a Simple, Inexpensive Multiple Enzyme-Linked Immunosorbent Assay Microdilution Plate Washer

    PubMed Central

    Stobbs, L. W.

    1990-01-01

    In this paper, plans are given for the construction of an inexpensive enzyme-linked immunosorbent assay plate washer from readily available materials. The wash unit uses an intermittent wash cycle based on a wash manifold cycling over the microdilution plates for a predetermined time. Laboratory tests showed that the unit provided reliable, rapid washing of plates with tap water, with no detectable contamination between wells. Substrate absorbance values for test samples from machine-washed plates were equal to or greater than absorbance values for corresponding samples from plates washed manually by an accepted protocol, by using either enzyme-linked immunosorbent assay wash buffer or tap water. Images PMID:16348216

  11. An fMRI study of musicians with focal dystonia during tapping tasks.

    PubMed

    Kadota, Hiroshi; Nakajima, Yasoichi; Miyazaki, Makoto; Sekiguchi, Hirofumi; Kohno, Yutaka; Amako, Masatoshi; Arino, Hiroshi; Nemoto, Koichi; Sakai, Naotaka

    2010-07-01

    Musician's dystonia is a type of task specific dystonia for which the pathophysiology is not clear. In this study, we performed functional magnetic resonance imaging to investigate the motor-related brain activity associated with musician's dystonia. We compared brain activities measured from subjects with focal hand dystonia and normal (control) musicians during right-hand, left-hand, and both-hands tapping tasks. We found activations in the thalamus and the basal ganglia during the tapping tasks in the control group but not in the dystonia group. For both groups, we detected significant activations in the contralateral sensorimotor areas, including the premotor area and cerebellum, during each tapping task. Moreover, direct comparison between the dystonia and control groups showed that the dystonia group had greater activity in the ipsilateral premotor area during the right-hand tapping task and less activity in the left cerebellum during the both-hands tapping task. Thus, the dystonic musicians showed irregular activation patterns in the motor-association system. We suggest that irregular neural activity patterns in dystonic subjects reflect dystonic neural malfunction and consequent compensatory activity to maintain appropriate voluntary movements.

  12. High-speed atomic force microscopy and peak force tapping control

    NASA Astrophysics Data System (ADS)

    Hu, Shuiqing; Mininni, Lars; Hu, Yan; Erina, Natalia; Kindt, Johannes; Su, Chanmin

    2012-03-01

    ITRS Roadmap requires defect size measurement below 10 nanometers and challenging classifications for both blank and patterned wafers and masks. Atomic force microscope (AFM) is capable of providing metrology measurement in 3D at sub-nanometer accuracy but has long suffered from drawbacks in throughput and limitation of slow topography imaging without chemical information. This presentation focus on two disruptive technology developments, namely high speed AFM and quantitative nanomechanical mapping, which enables high throughput measurement with capability of identifying components through concurrent physical property imaging. The high speed AFM technology has allowed the imaging speed increase by 10-100 times without loss of the data quality. Such improvement enables the speed of defect review on a wafer to increase from a few defects per hour to nearly 100 defects an hour, approaching the requirements of ITRS Roadmap. Another technology development, Peak Force Tapping, substantially simplified the close loop system response, leading to self-optimization of most challenging samples groups to generate expert quality data. More importantly, AFM also simultaneously provides a series of mechanical property maps with a nanometer spatial resolution during defect review. These nanomechanical maps (including elastic modulus, hardness, and surface adhesion) provide complementary information for elemental analysis, differentiate defect materials by their physical properties, and assist defect classification beyond topographic measurements. This paper will explain the key enabling technologies, namely high speed tip-scanning AFM using innovative flexure design and control algorithm. Another critical element is AFM control using Peak Force Tapping, in which the instantaneous tip-sample interaction force is measured and used to derive a full suite of physical properties at each imaging pixel. We will provide examples of defect review data on different wafers and media disks. The similar AFM-based defect review capacity was also applied to EUV masks.

  13. A new dimension of organizational justice: procedural voice.

    PubMed

    Jepsen, Denise; Rodwell, John

    2009-10-01

    Dimensionality of the Colquitt justice measures was investigated across a wide range of service occupations. Structural equation modeling of data from 410 survey respondents found support for the 4-factor model of justice (procedural, distributive, interpersonal, and informational), although significant improvement of model fit was obtained by including a new latent variable, "procedural voice," which taps employees' desire to express their views and feelings and influence results. The model was confirmed in a second sample (N = 505) in the same organization six months later.

  14. [Identification and isolation of non-tuberculous mycobacteria from environmental samples].

    PubMed

    Cafri, Uğur; Aslan, Gönül; Direkel, Sahin; Tarhan, Gülnur; Ceyhan, Ismail; Emekdaş, Gürol

    2010-07-01

    Non-tuberculous mycobacteria (NTM) found frequently in tap water and environment cause important opportunistic infections in immunocompromised patients. The aim of this study was to isolate and identify non-tuberculous mycobacteria in soil, raw milk and water distribution system samples in Mersin (a province located at Mediterranean region of Turkey). A total of 101 water, 124 soil and 40 milk samples collected from the central part and suburban parts of Mersin during November 2003-May 2004 period were included in the study. Water samples were collected from 29 different water distribution systems; soil samples from different parks and gardens and milk samples from raw milks sold at different districts. After the samples were processed by homogenization and decontamination, acid-fast staining and culture into Löwenstein-Jensen medium were performed. Acid-fast bacilli isolated from culture medium were identified by using conventional methods, polymerase chain reaction (PCR)-RFLP (Restriction Fragment Length Polymorphism) and INNO-LIPA Mycobacteria methods. NTM were identified from 4.9% (5/101) of water samples and 0.8% (1/124) of soil samples by culture and PCR. No NTM were detected in the raw milk samples. Three of the NTM strains isolated from water samples were defined as Mycobacterium chelonae type III and two as Mycobacterium kansasii type II. One NTM strain isolated from soil was defined as Mycobacterium fortuitum. It was of note that two of the five NTM positive water samples were tap water samples collected from hospitals. It was concluded that NTM colonization/contamination of water and environment in the hospitals was a potential risk factor in terms of nosocomial infections. Thus surveillance cultures of the water systems and the medical devices in the hospital are necessary to fix the source of NTM, to identify and type the strains and to establish effective control measures such as sterilization, disinfection, maintenance and modernization of water systems.

  15. Waterborne Norovirus outbreak at a seaside resort likely originating from municipal water distribution system failure.

    PubMed

    Giammanco, G M; Bonura, F; Urone, N; Purpari, G; Cuccia, M; Pepe, A; Li Muli, S; Cappa, V; Saglimbene, C; Mandolfo, G; Marino, A; Guercio, A; Di Bartolo, I; De Grazia, S

    2018-05-01

    In May 2016 a Norovirus (NoV) gastroenteritis outbreak involved a high school class visiting a seaside resort near Taormina (Mascali, Sicily). Twenty-four students and a teacher were affected and 17 of them showed symptoms on the second day of the journey, while the others got ill within the following 2 days. Symptoms included vomiting, diarrhoea and fever, and 12 students required hospitalisation. Stool samples tested positive for NoV genome by Real-Time polymerase chain reaction assay in all 25 symptomatic subjects. The GII.P2/GII.2 NoV genotype was linked to the outbreak by ORF1/ORF2 sequence analysis. The epidemiological features of the outbreak were consistent with food/waterborne followed by person-to-person and/or vomit transmission. Food consumed at a shared lunch on the first day of the trip was associated to illness and drinking un-bottled tap water was also considered as a risk factor. The analysis of water samples revealed the presence of bacterial indicators of faecal contamination in the water used in the resort as well as in other areas of the municipal water network, linking the NoV gastroenteritis outbreak to tap water pollution from sewage leakage. From a single water sample, an amplicon whose sequence corresponded to the capsid genotype recovered from patients could be obtained.

  16. Simultaneous detection of nine cyanotoxins in drinking water using dual solid-phase extraction and liquid chromatography-mass spectrometry.

    PubMed

    Yen, Hung-Kai; Lin, Tsair-Fuh; Liao, Pao-Chi

    2011-08-01

    A solid-phase extraction (SPE)-liquid chromatography (LC)-mass spectrometry (MS) method was developed to concentrate and detect nine cyanotoxins simultaneously, including six microcystins (MCs) congeners, nodularin (NOD), anatoxin-a (ATX) and cylindrospermopsin (CYN), in pure and natural waters. A dual cartridge SPE assembly was tested for the operating parameters of cyanotoxin extraction. A surrogate standard (SS), 1,9-diaminononane, was spiked in all the samples before the SPE extraction, and an internal standard (IS), 2,3,5-trimethylphenyl methyl carbamate, was spiked before LC/MS analysis. The method detection limit (MDL) was 2-100 ng/L for nine cyanotoxins in pure water and was increased by a factor of three to ten in a more complicated water matrix. The recoveries based on SS were between 83 and 104%, while those based on IS were 80-120%. The developed method was successfully employed in analyzing 33 water samples collected from eutrophic lakes, water treatment plants and distribution taps. MCs, NOD, and CYN were detected in the reservoir water, with concentrations as high as 36 μg/L. In addition, for the first time in Taiwan's tap water, CYN was detected at concentrations as high as 8.6 μg/L. Quality control data for the field samples shows that the analytical scheme developed is appropriate for monitoring cyanotoxins. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. 77 FR 37103 - Open Meeting of the Taxpayer Advocacy Panel Tax Forms and Publications Project Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-20

    ... more information please contact Ms. Knispel at 1-888-912-1227 or 718-488-3557, or write TAP Office, 10....improveirs.org . The agenda will include various IRS issues. Dated: June 13, 2012. Louis Morizio, Acting TAP...

  18. 75 FR 7541 - Open Meeting of the Area 3 Taxpayer Advocacy Panel (Including the States of Florida, Georgia...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-19

    ..., or write TAP Office, 1000 South Pine Island Road, Suite 340, Plantation, FL 33324, or post comments... Late Notice: Due to inclement weather and Federal office closings in the District of Columbia, key TAP...

  19. 76 FR 19334 - Pacific Gas and Electric Company; Notice of Application Accepted for Filing, Soliciting Motions...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-07

    ... length. The project also includes a 230-kV tap at PCWA's Ralston powerhouse. The tap is wholly contained... issues EA September 28, 2011. Comments on EA or EIS November 14, 2011. Modified terms and conditions...

  20. Spatio-temporal variation in the tap water isotope ratios of Salt Lake City: a novel indicator of urban water system structure and dynamics.

    NASA Astrophysics Data System (ADS)

    Jameel, M. Y.; Bowen, G. J.

    2015-12-01

    Public water supply systems are the life-blood of urban areas. How we use urban water systems affects more than human health and well-being. Our water use can alter a city's energy balance, including how much solar energy is absorbed as heat or reflected back into space. The severity of these effects, and the need to better understand connections between climate, water extraction, water use, and water use impacts, is strongest in areas of climatic aridity and substantial land-use change, such as the rapidly urbanizing areas of Utah. We have gathered and analyzed stable water isotope data from a series of semi-annual hydrological surveys (spring and fall, 2013 and 2014) in urban tap water sampled across the Salt Lake Valley. Our study has led to four major findings thus far: 1) Clear and substantial variation in tap water isotopic composition in space and time that can be linked to different water sources and management practices within the urban area, 2) There is a strong correlation between the range of observed isotope values and the population of water districts, reflecting use of water from multiple local and non-local sources in districts with high water demand, 3) Water isotopes reflect significant and variable loss of water due to evaporation of surface water resources and 4) Overall, tap water contains lower concentrations of the heavy H and O isotopes than does precipitation within the basin, reflecting the connection between city water supplies and mountain water sources. Our results highlight the utility of isotopic data as an indicator of heterogeneities within urban water systems, management practices and their variation across a major metropolitan area, and effects of climate variability on urban water supplies

  1. Porous poly-ether ether ketone (PEEK) manufactured by a novel powder route using near-spherical salt bead porogens: characterisation and mechanical properties.

    PubMed

    Siddiq, Abdur R; Kennedy, Andrew R

    2015-02-01

    Porous PEEK structures with approximately 85% open porosity have been made using PEEK-OPTIMA® powder and a particulate leaching technique using porous, near-spherical, sodium chloride beads. A novel manufacturing approach is presented and compared with a traditional dry mixing method. Irrespective of the method used, the use of near-spherical beads with a fairly narrow size range results in uniform pore structures. However the integration, by tapping, of fine PEEK into a pre-existing network salt beads, followed by compaction and "sintering", produces porous structures with excellent repeatability and homogeneity of density; more uniform pore and strut sizes; an improved and predictable level of connectivity via the formation of "windows" between the cells; faster salt removal rates and lower levels of residual salt. Although tapped samples show a compressive yield stress >1 MPa and stiffness >30 MPa for samples with 84% porosity, the presence of windows in the cell walls means that tapped structures show lower strengths and lower stiffnesses than equivalent structures made by mixing. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Determination of radon concentration in water using RAD7 with RAD H{sub 2}O accessories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malik, M. F. I.; Rabaiee, N. A.; Jaafar, M. S.

    In the last decade, the radon issue has become one of the major problems of radiation protection. Radon exposure occurs when using water for showering, washing dishes, cooking and drinking water. RAD7 and Rad H20 accessories were used in order to measure radon concentration in water sample. In this study, four types of water were concerns which are reverse osmosis (drinking water), mineral water, tap water and well water. Reverse osmosis (drinking water) and mineral water were bought from the nearest supermarket while tap water and well water were taken from selected areas of Pulau Pinang and Kedah. Total 20more » samples were taken with 5 samples for each type of water. The measured radon concentration ranged from 2.9±2.9 to 79.5±17 pCi/L, 2.9±2.9 to 67.8±16 pCi/L, 15.97±7 to 144.25±24 pCi/L and 374.89±37 to 6409.03±130 pCi/L in reverse osmosis (drinking water), mineral water, tap water and well water. Well water has the highest radon compared to others. It was due to their geological element such as granite. Results for all types of water are presented and compared with maximum contamination limit (MCL) recommended by United State Environmental Protection Agency (USEPA) which is 300pCi/L. Reverse osmosis water, mineral water and tap water were fall below MCL. However, well water was exceeded maximum level that was recommended. Thus, these findings were suggested that an action should be taken to reduce radon concentration level in well water as well as reduce a health risk towards the public.« less

  3. Pharmaceuticals in tap water: human health risk assessment and proposed monitoring framework in China.

    PubMed

    Leung, Ho Wing; Jin, Ling; Wei, Si; Tsui, Mirabelle Mei Po; Zhou, Bingsheng; Jiao, Liping; Cheung, Pak Chuen; Chun, Yiu Kan; Murphy, Margaret Burkhardt; Lam, Paul Kwan Sing

    2013-07-01

    Pharmaceuticals are known to contaminate tap water worldwide, but the relevant human health risks have not been assessed in China. We monitored 32 pharmaceuticals in Chinese tap water and evaluated the life-long human health risks of exposure in order to provide information for future prioritization and risk management. We analyzed samples (n = 113) from 13 cities and compared detected concentrations with existing or newly-derived safety levels for assessing risk quotients (RQs) at different life stages, excluding the prenatal stage. We detected 17 pharmaceuticals in 89% of samples, with most detectable concentrations (92%) at < 50 ng/L. Caffeine (median-maximum, nanograms per liter: 24.4-564), metronidazole (1.8-19.3), salicylic acid (16.6-41.2), clofibric acid (1.2-3.3), carbamazepine (1.3-6.7), and dimetridazole (6.9-14.7) were found in ≥ 20% of samples. Cities within the Yangtze River region and Guangzhou were regarded as contamination hot spots because of elevated levels and frequent positive detections. Of the 17 pharmaceuticals detected, 13 showed very low risk levels, but 4 (i.e., dimetridazole, thiamphenicol, sulfamethazine, and clarithromycin) were found to have at least one life-stage RQ ≥ 0.01, especially for the infant and child life stages, and should be considered of high priority for management. We propose an indicator-based monitoring framework for providing information for source identification, water treatment effectiveness, and water safety management in China. Chinese tap water is an additional route of human exposure to pharmaceuticals, particularly for dimetridazole, although the risk to human health is low based on current toxicity data. Pharmaceutical detection and application of the proposed monitoring framework can be used for water source protection and risk management in China and elsewhere.

  4. Super-Nyquist shaping and processing technologies for high-spectral-efficiency optical systems

    NASA Astrophysics Data System (ADS)

    Jia, Zhensheng; Chien, Hung-Chang; Zhang, Junwen; Dong, Ze; Cai, Yi; Yu, Jianjun

    2013-12-01

    The implementations of super-Nyquist pulse generation, both in a digital field using a digital-to-analog converter (DAC) or an optical filter at transmitter side, are introduced. Three corresponding signal processing algorithms at receiver are presented and compared for high spectral-efficiency (SE) optical systems employing the spectral prefiltering. Those algorithms are designed for the mitigation towards inter-symbol-interference (ISI) and inter-channel-interference (ICI) impairments by the bandwidth constraint, including 1-tap constant modulus algorithm (CMA) and 3-tap maximum likelihood sequence estimation (MLSE), regular CMA and digital filter with 2-tap MLSE, and constant multi-modulus algorithm (CMMA) with 2-tap MLSE. The principles and prefiltering tolerance are given through numerical and experimental results.

  5. Mycobacterium mucogenicum and other non-tuberculous mycobacteria in potable water of a trauma hospital: a potential source for human infection.

    PubMed

    Fernandez-Rendon, E; Cerna-Cortes, J F; Ramirez-Medina, M A; Helguera-Repetto, A C; Rivera-Gutierrez, S; Estrada-Garcia, T; Gonzalez-Y-Merchand, J A

    2012-01-01

    This study examined the frequency of occurrence of non-tuberculous mycobacteria (NTM) in potable water samples from a main trauma hospital in Mexico City. Sixty-nine potable water samples were collected, 23 from each source: cistern, kitchen tap and bathroom showers. Of the 69 samples, 36 harboured NTM species. Twenty-nine of the 36 isolates were Mycobacterium mucogenicum, two Mycobacterium rhodesiae, one Mycobacterium peregrinum, one Mycobacterium fortuitum and three were Mycobacterium spp. Hospital potable water harbouring NTM represents a potential source for nosocomial infections, therefore we suggest that hospital potable water microbiological guidelines should include testing for NTM species. Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  6. Lead Tap Sampling Approaches: What Do They Tell You

    EPA Science Inventory

    There is no single, universally applicable sampling approach for lead in drinking water. The appropriate type of sampling is dictated by the question being asked. There is no reason when a customer asks to have their home water tested to see if it's "safe" that they s...

  7. Developments in signal processing and interpretation in laser tapping

    NASA Astrophysics Data System (ADS)

    Perton, M.; Neron, C.; Blouin, A.; Monchalin, J.-P.

    2013-01-01

    A novel technique, called laser-tapping, based on the thermoelastic excitation by laser like laser-ultrasonics has been previously introduced for inspecting honeycomb and foam core structures. If the top skin is delaminated or detached from the substrate, the detached layer is driven into vibration. The interpretation of the vibrations in terms of Lamb wave resonances is first discussed for a flat bottom hole configuration and then used to determine appropriate signal processing for samples such as honeycomb structures.

  8. Effects of channel tap spacing on delay-lock tracking

    NASA Astrophysics Data System (ADS)

    Dana, Roger A.; Milner, Brian R.; Bogusch, Robert L.

    1995-12-01

    High fidelity simulations of communication links operating through frequency selective fading channels require both accurate channel models and faithful reproduction of the received signal. In modern radio receivers, processing beyond the analog-to-digital converter (A/D) is done digitally, so a high fidelity simulation is actually an emulation of this digital signal processing. The 'simulation' occurs in constructing the output of the A/D. One approach to constructing the A/D output is to convolve the channel impulse response function with the combined impulse response of the transmitted modulation and the A/D. For both link simulations and hardware channel simulators, the channel impulse response function is then generated with a finite number of samples per chip, and the convolution is implemented in a tapped delay line. In this paper we discuss the effects of the channel model tap spacing on the performance of delay locked loops (DLLs) in both direct sequence and frequency hopped spread spectrum systems. A frequency selective fading channel is considered, and the channel impulse response function is constructed with an integer number of taps per modulation symbol or chip. The tracking loop time delay is computed theoretically for this tapped delay line channel model and is compared to the results of high fidelity simulations of actual DLLs. A surprising result is obtained. The performance of the DLL depends strongly on the number of taps per chip. As this number increases the DLL delay approaches the theoretical limit.

  9. Divergence of stable isotopes in tap water across China

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Sihan; Hu, Hongchang; Tian, Fuqiang

    Stable isotopes in water (e.g., δ2H and δ18O) are important indicators of hydrological and ecological patterns and processes. Tap water can reflect integrated features of regional hydrological processes and human activities. China is a large country with significant meteorological and geographical variations. This report presents the first national-scale survey of Stable Isotopes in Tap Water (SITW) across China. 780 tap water samples have been collected from 95 cities across China from December 2014 to December 2015. (1) Results yielded the Tap Water Line in China is δ2H = 7.72 δ18O + 6.57 (r2 = 0.95). (2) SITW spatial distribution presentsmore » typical "continental effect". (3) SITW seasonal variations indicate clearly regional patterns but no trends at the national level. (4) SITW can be correlated in some parts with geographic or meteorological factors. This work presents the first SITW map in China, which sets up a benchmark for further stable isotopes research across China. This is a critical step toward monitoring and investigating water resources in climate-sensitive regions, so the human-hydrological system. These findings could be used in the future to establish water management strategies at a national or regional scale. Title: Divergence of stable isotopes in tap water across China Authors: Zhao, SH; Hu, HC; Tian, FQ; Tie, Q; Wang, LX; Liu, YL; Shi, CX Source: SCIENTIFIC REPORTS, 7 10.1038/srep43653 MAR 2 2017« less

  10. Investigation of radon level in air and tap water of workplaces at Thailand Institute of Nuclear Technology, Thailand

    NASA Astrophysics Data System (ADS)

    Sola, P.; Youngchuay, U.; Kongsri, S.; Kongtana, A.

    2017-06-01

    Thailand Institute of Nuclear Technology (TINT) has continuously monitored radiation exposure and radionuclide in workplaces specifically radon gas to estimate effective dose for workers. Radon exposure is the second leading cause of lung cancer in the world. In this study, radon in air and tap water at building no. 3, 7, 8, 9 and 18 on Ongkharak site of TINT have been measured for 5 years from 2012 to 2016. Radon level in air and tap water were investigated on 83 stations (workplaces) and 54 samples, respectively. Radon concentrations in air and tap water were measured by using the pulsed ionization chamber (ATMOS 12 DPX). Indoor radon concentrations in air were in the range of 12-138 Bq.m-3 with an average value of 30.13±17.05 Bq.m-3. Radon concentrations in tap water were in the range of 0.10 to 2.89 Bq.l-1 with an average value of 0.51±0.55 Bq.l-1. The results of radon concentrations at TINT were below the US Environmental Protection Agency (US EPA) safety limit of 148 Bq.m-3 and 150 Bq.l-1, for, air and tap water, respectively. The average effective dose for TINT’s workers due to indoor radon exposure was approximately 0.20±0.11 mSv.y-1. The value is 100 times less than the annual dose limit for limit occupational radiation worker defined by the International Commission on Radiological Protection (ICRP). As a result, the TINT’s workplaces are radiologically safe from radon content in air and tap water.

  11. Hydrogen and oxygen stable isotope ratios of milk in the United States.

    PubMed

    Chesson, Lesley A; Valenzuela, Luciano O; O'Grady, Shannon P; Cerling, Thure E; Ehleringer, James R

    2010-02-24

    Models of hydrogen and oxygen incorporation in human tissues recognize the impact of geographic location on the isotopic composition of fluid intake, but inputs can include nonlocal beverages, such as milk. Milk and cow drinking water were collected from dairies, and commercially available milk was purchased from supermarkets and fast food restaurants. It was hypothesized that milk water delta(2)H and delta(18)O values record geographic location information. Correlations between milk water isotope ratios and purchase location tap water were significant. However, the amount of variation in milk delta(2)H and delta(18)O values explained by tap water was low, suggesting a single estimation of fluid input isotope ratios may not always be adequate in studies. The delta(2)H and delta(18)O values of paired milk and cow drinking water were related, suggesting potential for geographical origin assignment using stable isotope analysis. As an application example, milk water delta(18)O values were used to predict possible regions of origin for restaurant samples.

  12. Automatic and Objective Assessment of Alternating Tapping Performance in Parkinson's Disease

    PubMed Central

    Memedi, Mevludin; Khan, Taha; Grenholm, Peter; Nyholm, Dag; Westin, Jerker

    2013-01-01

    This paper presents the development and evaluation of a method for enabling quantitative and automatic scoring of alternating tapping performance of patients with Parkinson's disease (PD). Ten healthy elderly subjects and 95 patients in different clinical stages of PD have utilized a touch-pad handheld computer to perform alternate tapping tests in their home environments. First, a neurologist used a web-based system to visually assess impairments in four tapping dimensions (‘speed’, ‘accuracy’, ‘fatigue’ and ‘arrhythmia’) and a global tapping severity (GTS). Second, tapping signals were processed with time series analysis and statistical methods to derive 24 quantitative parameters. Third, principal component analysis was used to reduce the dimensions of these parameters and to obtain scores for the four dimensions. Finally, a logistic regression classifier was trained using a 10-fold stratified cross-validation to map the reduced parameters to the corresponding visually assessed GTS scores. Results showed that the computed scores correlated well to visually assessed scores and were significantly different across Unified Parkinson's Disease Rating Scale scores of upper limb motor performance. In addition, they had good internal consistency, had good ability to discriminate between healthy elderly and patients in different disease stages, had good sensitivity to treatment interventions and could reflect the natural disease progression over time. In conclusion, the automatic method can be useful to objectively assess the tapping performance of PD patients and can be included in telemedicine tools for remote monitoring of tapping. PMID:24351667

  13. Automatic and objective assessment of alternating tapping performance in Parkinson's disease.

    PubMed

    Memedi, Mevludin; Khan, Taha; Grenholm, Peter; Nyholm, Dag; Westin, Jerker

    2013-12-09

    This paper presents the development and evaluation of a method for enabling quantitative and automatic scoring of alternating tapping performance of patients with Parkinson's disease (PD). Ten healthy elderly subjects and 95 patients in different clinical stages of PD have utilized a touch-pad handheld computer to perform alternate tapping tests in their home environments. First, a neurologist used a web-based system to visually assess impairments in four tapping dimensions ('speed', 'accuracy', 'fatigue' and 'arrhythmia') and a global tapping severity (GTS). Second, tapping signals were processed with time series analysis and statistical methods to derive 24 quantitative parameters. Third, principal component analysis was used to reduce the dimensions of these parameters and to obtain scores for the four dimensions. Finally, a logistic regression classifier was trained using a 10-fold stratified cross-validation to map the reduced parameters to the corresponding visually assessed GTS scores. Results showed that the computed scores correlated well to visually assessed scores and were significantly different across Unified Parkinson's Disease Rating Scale scores of upper limb motor performance. In addition, they had good internal consistency, had good ability to discriminate between healthy elderly and patients in different disease stages, had good sensitivity to treatment interventions and could reflect the natural disease progression over time. In conclusion, the automatic method can be useful to objectively assess the tapping performance of PD patients and can be included in telemedicine tools for remote monitoring of tapping.

  14. [Mutagenicity study of water samples from a waterworks taking Yangtze River as its water source in Jiangsu Province].

    PubMed

    Xiao, Sanhua; Luo, Lan; Qiao, Qian; Lü, Xuemin; Wang, Yanhui; Feng, Lin; Tang, Fei; Wang, Haiyong; Bie, Nana; Wang, Yuehong

    2017-05-01

    To understand the occurrence and change of mutagencity of water samples in the process of drinking water treatment and distribution in a waterworks taking Yangtze River as its water source in Jiangsu Province. Large volume of inlet water, finished water and tap water samples were extracted by XAD-2 resin. Mutagencities were assessed by Ames test and a mutation ratio( MR) of 2 or greater was judged as a positive result. Compared with the samples with S9, samples without S9 presented more positive results( P = 0. 005). That water treatment elevated MR values( P = 0. 007) while the pipe transport made MR values down( P = 0. 038) was observed in samples without S9. The tap water showed weaker mutagenicities than the raw water in samples with S9( P = 0. 008). Compared to the raw water samples, the finished water samples showed more positive results(-S9) and lower MR values( + S9, P =0. 002). Significant mutagenicities of water samples from the Yangtze Riverand its processed water were presented, and frame shit and direct mutagens deserved special concern.

  15. A pilot study on the assessment of trace organic contaminants including pharmaceuticals and personal care products from on-site wastewater treatment systems along Skaneateles Lake in New York State, USA.

    PubMed

    Subedi, Bikram; Codru, Neculai; Dziewulski, David M; Wilson, Lloyd R; Xue, Jingchuan; Yun, Sehun; Braun-Howland, Ellen; Minihane, Christine; Kannan, Kurunthachalam

    2015-04-01

    On-site wastewater treatment systems (OWTSs or septic systems) are designed to treat and dispose effluents on the same property that produces the wastewater. Approximately 25% of the U.S. population is served by such facilities. Nevertheless, studies on the treatment efficiency and discharge of organic contaminants through septic effluents are lacking. This pilot study showed the occurrence of organic contaminants including pharmaceuticals and personal care products (PPCPs), perfluoroalkyl surfactants (PFASs), polybrominated diphenyl ethers (PBDEs), and polychlorinated biphenyls (PCBs) in septic effluents, adjacent lake water samples, household drinking water in homes that use lake water or a well adjacent to the lake as a source of drinking water, and offshore lake water samples. Septic effluent as well as lake and tap water samples were collected from several households with OWTSs around Skaneateles Lake located in central New York. The advanced on-site systems were installed in some households for the purpose of limiting nutrient levels in the effluent to protect the local surface water. Additionally, because many of these systems serve homes with limited land, advanced treatment systems were needed. The median concentrations of ten PPCPs (ranged from 0.45 to 388 ng/L) and eleven PFASs (ranged from 0.20 to 14.6 ng/L) in septic water were significantly higher (p ≤ 0.01) than in lake water samples. The median concentrations of PPCPs and PFASs in lake and tap water samples were not significantly different (p ≥ 0.65). The median concentrations of ∑PBDEs in septic, lake, and tap water samples were 7.47, 3.49, and 2.22 ng/L, respectively, and those for ∑PCBs were 33.1, 29.2, and 28.6 ng/L, respectively. The mass flux of PPCPs (i.e. the mass flow of PPCPs per unit area per unit time) through the disposal of treated septic effluent from textile biofilter and aerobic treatments to the dispersal unit ranged from 12 (carbamazepine) to 66900 μg/m(2)/day (caffeine) whereas that for PFASs ranged from 7.0 (perfluorobutanesulfonate) to 833 μg/m(2)/day (perfluorooctanoic acid). Based on the ratio of measured concentrations and method detection limit, triclocarban, perfluorooctanoic acid, and perfluorooctanesulfonate have the potential to be used as chemical tracers of septic water contamination in Skaneateles Lake. The median concentrations of atenolol, a beta-blocker drug, in septic water were significantly (ρ = 0.86, p = 0.01) correlated with enterococci counts. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. 77 FR 37102 - Open Meeting of the Taxpayer Advocacy Panel Small Business/Self-Employed Decreasing Non-Filers...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-20

    ... information please contact Ms. Robb at 1-888-912-1227 or 414-231-2360, or write TAP Office, Stop 1006MIL, 211....improveirs.org . The agenda will include various IRS issues. Dated: June 13, 2012. Louis Morizio, Acting TAP...

  17. 75 FR 4630 - Open Meeting of the Area 6 Taxpayer Advocacy Panel (Including the States of Arizona, Colorado...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-28

    ... 1-888-912-1227 or 206-220-6098, or write TAP Office, 915 2nd Avenue, MS W-406, Seattle, WA 98174 or.... Reason for Late Notice: Due to year end leave and mandatory training in January key TAP staff were...

  18. 75 FR 7539 - Open Meeting of the Area 5 Taxpayer Advocacy Panel (Including the States of Iowa, Kansas...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-19

    ... please contact Ms. Robb at 1-888-912-1227 or 414- 231-2360, or write TAP Office Stop 1006MIL, 211 West... Federal office closings in the District of Columbia, key TAP staff was unavailable to prepare and submit...

  19. Transversus abdominis plane block vs. wound infiltration in Caesarean section: a randomised controlled trial.

    PubMed

    Telnes, A; Skogvoll, E; Lonnée, H

    2015-04-01

    Multiple studies suggest that transversus abdominis plane (TAP) block (without intrathecal morphine) after Caesarean section (CS) reduces post-operative morphine consumption. In our study, we wanted to compare the analgesic effect of TAP block with infiltration of the wound after CS. We included 60 pregnant women scheduled for elective CS under spinal anaesthesia in a randomised, single-centre, double-blind study. Thirty patients received ultrasound-guided TAP block using 20 ml bupivacaine 0.25% with adrenaline 5 μg/ml bilaterally and 20 ml normal saline as wound infiltration (TAP group). The other 30 patients (the control group) received normal saline 20 ml bilaterally in the TAP, and 20 ml bupivacaine 0.25% with adrenaline 5 μg/ml as wound infiltration. The main outcome was cumulative morphine consumption at 48 h after surgery. In addition, continuous morphine consumption, pain scores and side effects were registered. Fifty-seven patients completed the study. Cumulative morphine consumption at 48 h (mean±standard deviation) was 41±34 mg in the TAP group and 38±27 mg in the control group (P=0.7); a difference of 3 mg (95% confidence interval -13 to 19 mg). Morphine consumption at any time up to 48 h was virtually identical in both groups. Side effects were similar, except for a higher degree of sedation in the TAP group (P=0.04). Compared with wound infiltration with local anaesthetics, TAP block did not reduce cumulative morphine consumption following CS. The TAP block was associated with more pronounced sedation. © 2015 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  20. Performance of a novel high throughput method for the determination of VX in drinking water samples.

    PubMed

    Knaack, Jennifer S; Zhou, Yingtao; Magnuson, Matthew; Silvestri, Erin; Johnson, Rudolph C

    2013-03-05

    VX (O-ethyl-S-(2-diisopropylaminoethyl) methylphosphonothioate) is a highly toxic organophosphorus nerve agent, and even low levels of contamination in water can be harmful. Measurement of low concentrations of VX in aqueous matrixes is possible using an immunomagnetic scavenging technique and detection using liquid chromatography/tandem-mass spectrometry. Performance of the method was characterized in high-performance liquid chromatography (HPLC)-grade water preserved with sodium omadine, an antimicrobial agent, and sodium thiosulfate, a dechlorinating agent, over eight analytical batches with quality control samples analyzed over 10 days. The minimum reportable level was 25 ng/L with a linear dynamic range up to 4.0 μg/L. The mean accuracies for two quality control samples containing VX at concentrations of 0.250 and 2.00 μg/L were 102 ± 3% and 103 ± 6%, respectively. The stability of VX was determined in five tap water samples representing a range of water quality parameters and disinfection practices over a 91 day period. In preserved tap water samples, VX recovery was between 81 and 92% of the fortified amount, 2.0 μg/L, when analyzed immediately after preparation. Recovery of VX decreased to between 31 and 45% of the fortified amount after 91 days, indicating hydrolysis of VX. However, the preservatives minimized the hydrolysis rate to close to the theoretical limit. The ability to detect low concentrations of VX in preserved tap water 91 days after spiking suggests applicability of this method for determining water contamination with VX and utility during environmental remediation.

  1. Culture Method and PCR for the Detection of Helicobacter pylori in Drinking Water in Basrah Governorate Iraq

    PubMed Central

    Al-Sulami, A. A.; Al-Edani, T. A. A.; Al-Abdula, A. A.

    2012-01-01

    Helicobacter pylori is recognized by the World Health Organization to be the primary cause of peptic ulcers, chronic gastritis, and stomach cancer, though the source of human infection is not well understood. One of the problems in understanding the source of human contamination is the difficulty in isolating the organism from the environment. However, the combination of PCR results with those of culturing of 471 drinking water samples can provide a more accurate picture of H. pylori detection. In this method 78 presumptive H. pylori colonies out of 266 tap water samples were obtained in the preliminary detection on modified Columbia agar (MCUA) slant relying on urease positivity with a rate of 29.3%. However, only 11 out of them were confirmed by Gram staining and biochemical tests reducing the rate to 4.13% whereas only 3 (1.46%) from 205 reverse osmosis (RO) water samples. Furthermore, only 6 (54.5%) out of the 11 isolates from tap water and 1 (33.3%) of the 3 RO isolates were confirmed by 16SrRNA PCR. Thus PCR confirmation reduced the rate to 2.2%. In addition, only 4 (4%) of 100 tap water samples negative for H. pylori by culture method were H. pylori positive by 16SrRNA. Water samples were collected from 24 districts of Basrah Governorate from February–December 2009. The direct recovery of H. pylori from drinking water is both alarming and scientifically exciting in terms of the investigation of its epidemiology. PMID:22778721

  2. Occurrence of nonylphenol and bisphenol A in household water pipes made of different materials.

    PubMed

    Cheng, Yang-Chen; Chen, Huei-Wen; Chen, Wen-Ling; Chen, Chia-Yang; Wang, Gen-Shuh

    2015-10-01

    We assessed the occurrence of nonylphenol (NP) and bisphenol A (BPA) in tap water supplied through polyvinyl chloride (PVC), stainless steel, and galvanized pipes. Water samples were collected from selected households in Taipei and Kaohsiung (Northern and Southern Taiwan, respectively) in different seasons to elucidate the effects of pipeline materials and ambient temperatures on NP and BPA concentrations in tap water. We detected higher concentrations of NP in tap water from households using PVC pipes (64-195 ng/L) than from those using stainless steel pipes (17-44 ng/L) and galvanized pipes (27-96 ng/L). To verify that water can absorb NP and BPA from PVC pipes, we sealed Milli-Q and tap water in PVC and stainless steel pipes to assess the potential release of NP and BPA from the pipes into the water. Both NP and BPA concentrations initially increased with contact time in the PVC pipes, and the concentration profiles during the retention appeared to be more strongly affected by ambient temperatures. Concentration variations in the stainless steel pipes were smaller than those in the PVC pipes.

  3. Comprehensive Genome-Wide Classification Reveals That Many Plant-Specific Transcription Factors Evolved in Streptophyte Algae

    PubMed Central

    Wilhelmsson, Per K I; Mühlich, Cornelia; Ullrich, Kristian K

    2017-01-01

    Abstract Plant genomes encode many lineage-specific, unique transcription factors. Expansion of such gene families has been previously found to coincide with the evolution of morphological complexity, although comparative analyses have been hampered by severe sampling bias. Here, we make use of the recently increased availability of plant genomes. We have updated and expanded previous rule sets for domain-based classification of transcription associated proteins (TAPs), comprising transcription factors and transcriptional regulators. The genome-wide annotation of these protein families has been analyzed and made available via the novel TAPscan web interface. We find that many TAP families previously thought to be specific for land plants actually evolved in streptophyte (charophyte) algae; 26 out of 36 TAP family gains are inferred to have occurred in the common ancestor of the Streptophyta (uniting the land plants—Embryophyta—with their closest algal relatives). In contrast, expansions of TAP families were found to occur throughout streptophyte evolution. 17 out of 76 expansion events were found to be common to all land plants and thus probably evolved concomitant with the water-to-land-transition. PMID:29216360

  4. Evaluation of minerals content of drinking water in Malaysia.

    PubMed

    Azlan, Azrina; Khoo, Hock Eng; Idris, Mohd Aizat; Ismail, Amin; Razman, Muhammad Rizal

    2012-01-01

    The drinking and mineral water samples obtained from different geographical locations had concentrations of the selected minerals lower than the standard limits, except for manganese, arsenic, and fluoride. The concentrations of manganese and arsenic in two mineral water samples were slightly higher than the standard international recommended limits. One mineral water sample had a fluoride concentration higher than the standard limits, whereas manganese was not detected in nine drinking and mineral water samples. Most of the selected minerals found in the tap water samples were below the international standard limits, except for iron and manganese. The concentrations of iron and manganese in the tap water samples were higher than the standard limits, which were obtained from one and three of the studied locations, respectively. The potable water obtained from various manufacturers and locations in Peninsular Malaysia is safe for consumption, as the minerals concentrations were below the standard limits prescribed by the Malaysian Food Regulations of 1985. The data obtained may also provide important information related to daily intake of these minerals from drinking water.

  5. Evaluation of Minerals Content of Drinking Water in Malaysia

    PubMed Central

    Azlan, Azrina; Khoo, Hock Eng; Idris, Mohd Aizat; Ismail, Amin; Razman, Muhammad Rizal

    2012-01-01

    The drinking and mineral water samples obtained from different geographical locations had concentrations of the selected minerals lower than the standard limits, except for manganese, arsenic, and fluoride. The concentrations of manganese and arsenic in two mineral water samples were slightly higher than the standard international recommended limits. One mineral water sample had a fluoride concentration higher than the standard limits, whereas manganese was not detected in nine drinking and mineral water samples. Most of the selected minerals found in the tap water samples were below the international standard limits, except for iron and manganese. The concentrations of iron and manganese in the tap water samples were higher than the standard limits, which were obtained from one and three of the studied locations, respectively. The potable water obtained from various manufacturers and locations in Peninsular Malaysia is safe for consumption, as the minerals concentrations were below the standard limits prescribed by the Malaysian Food Regulations of 1985. The data obtained may also provide important information related to daily intake of these minerals from drinking water. PMID:22649292

  6. Uncovering beat deafness: detecting rhythm disorders with synchronized finger tapping and perceptual timing tasks.

    PubMed

    Dalla Bella, Simone; Sowiński, Jakub

    2015-03-16

    A set of behavioral tasks for assessing perceptual and sensorimotor timing abilities in the general population (i.e., non-musicians) is presented here with the goal of uncovering rhythm disorders, such as beat deafness. Beat deafness is characterized by poor performance in perceiving durations in auditory rhythmic patterns or poor synchronization of movement with auditory rhythms (e.g., with musical beats). These tasks include the synchronization of finger tapping to the beat of simple and complex auditory stimuli and the detection of rhythmic irregularities (anisochrony detection task) embedded in the same stimuli. These tests, which are easy to administer, include an assessment of both perceptual and sensorimotor timing abilities under different conditions (e.g., beat rates and types of auditory material) and are based on the same auditory stimuli, ranging from a simple metronome to a complex musical excerpt. The analysis of synchronized tapping data is performed with circular statistics, which provide reliable measures of synchronization accuracy (e.g., the difference between the timing of the taps and the timing of the pacing stimuli) and consistency. Circular statistics on tapping data are particularly well-suited for detecting individual differences in the general population. Synchronized tapping and anisochrony detection are sensitive measures for identifying profiles of rhythm disorders and have been used with success to uncover cases of poor synchronization with spared perceptual timing. This systematic assessment of perceptual and sensorimotor timing can be extended to populations of patients with brain damage, neurodegenerative diseases (e.g., Parkinson's disease), and developmental disorders (e.g., Attention Deficit Hyperactivity Disorder).

  7. Occurrence of non-steroidal anti-inflammatory drugs in Tehran source water, municipal and hospital wastewaters, and their ecotoxicological risk assessment.

    PubMed

    Eslami, Akbar; Amini, Mostafa M; Yazdanbakhsh, Ahmad Reza; Rastkari, Noushin; Mohseni-Bandpei, Anoushiravan; Nasseri, Simin; Piroti, Ehsan; Asadi, Anvar

    2015-12-01

    Pharmaceuticals are becoming widely distributed in waters and wastewaters and pose a serious threat to public health. The present study aimed to analyze non-steroidal anti-inflammatory drugs (NSAIDs) in surface waters, drinking water, and wastewater in Tehran, Iran. Thirty-six samples were collected from surface waters, tap water, and influent and effluent of municipal and hospital wastewater treatment plants (WWTP). A solid-phase extraction (SPE) followed by liquid chromatography-tandem mass spectrometry method was used for the determination of pharmaceuticals, namely ibuprofen (IBP), naproxen (NPX), diclofenac (DIC), and indomethacin (IDM). IBP was found in most of the samples and had the highest concentration. The highest concentrations of NSAIDs were found in the municipal WWTP influents and hospital WWTP effluents. In the municipal WWTP influent samples, the concentrations of IBP, NPX, DIC, and IDM were 1.05, 0.43, 0.23, and 0.11 μg/L, respectively. DIC was found only in one river sample. All NSAIDs were detected in tap water samples. However, their concentration was very low and the maximum values for IBP, NPX, DIC, and IDM were 47, 39, 24, and 37 ng/L, respectively, in tap water samples. Results showed that the measured pharmaceuticals were detected in all rivers with low concentrations in nanograms per liter range, except DIC which was found only in one river. Furthermore, this study showed that the aforementioned pharmaceuticals are not completely removed during their passage through WWTPs. A potential environmental risk of selected NSAIDs for the urban wastewater has been discussed. However, given their low measured concentrations, no ecotoxicological effect is suspected to occur.

  8. Molecular analysis of point-of-use municipal drinking water microbiology.

    PubMed

    Holinger, Eric P; Ross, Kimberly A; Robertson, Charles E; Stevens, Mark J; Harris, J Kirk; Pace, Norman R

    2014-02-01

    Little is known about the nature of the microbiology in tap waters delivered to consumers via public drinking water distribution systems (DWDSs). In order to establish a broader understanding of the microbial complexity of public drinking waters we sampled tap water from seventeen different cities between the headwaters of the Arkansas River and the mouth of the Mississippi River and determined the bacterial compositions by pyrosequencing small subunit rRNA genes. Nearly 98% of sequences observed among all systems fell into only 5 phyla: Proteobacteria (35%), Cyanobacteria (29%, including chloroplasts), Actinobacteria (24%, of which 85% were Mycobacterium spp.), Firmicutes (6%), and Bacteroidetes (3.4%). The genus Mycobacterium was the most abundant taxon in the dataset, detected in 56 of 63 samples (16 of 17 cities). Among the more rare phylotypes, considerable variation was observed between systems, and was sometimes associated with the type of source water, the type of disinfectant, or the concentration of the environmental pollutant nitrate. Abundant taxa (excepting Cyanobacteria and chloroplasts) were generally similar from system to system, however, regardless of source water type or local land use. The observed similarity among the abundant taxa between systems may be a consequence of the selective influence of chlorine-based disinfection and the common local environments of DWDS and premise plumbing pipes. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. p63 regulates glutaminase 2 expression

    PubMed Central

    Giacobbe, Arianna; Bongiorno-Borbone, Lucilla; Bernassola, Francesca; Terrinoni, Alessandro; Markert, Elke Katrin; Levine, Arnold J.; Feng, Zhaohui; Agostini, Massimilano; Zolla, Lello; Agrò, Alessandro Finazzi; Notterman, Daniel A.; Melino, Gerry; Peschiaroli, Angelo

    2013-01-01

    The transcription factor p63 is critical for many biological processes, including development and maintenance of epidermal tissues and tumorigenesis. Here, we report that the TAp63 isoforms regulate cell metabolism through the induction of the mitochondrial glutaminase 2 (GLS2) gene both in primary cells and tumor cell lines. By ChIP analysis and luciferase assay, we confirmed that TAp63 binds directly to the p53/p63 consensus DNA binding sequence within the GLS2 promoter region. Given the critical role of p63 in epidermal differentiation, we have investigated the regulation of GLS2 expression during this process. GLS2 and TAp63 expression increases during the in vitro differentiation of primary human keratinocytes, and depletion of GLS2 inhibits skin differentiation both at molecular and cellular levels. We found that GLS2 and TAp63 expression are concomitantly induced in cancer cells exposed to oxidative stresses. siRNA-mediated depletion of GLS2 sensitizes cells to ROS-induced apoptosis, suggesting that the TAp63/GLS2 axis can be functionally important as a cellular antioxidant pathway in the absence of p53. Accordingly, we found that GLS2 is upregulated in colon adenocarcinoma. Altogether, our findings demonstrate that GLS2 is a bona fide TAp63 target gene, and that the TAp63-dependent regulation of GLS2 is important for both physiological and pathological processes. PMID:23574722

  10. Detection of Cryptosporidium sp. Oocyst and Giardia sp. cyst in faucet water samples from cattle and goat farms in Taiwan.

    PubMed

    Watanabe, Yuko; Kimura, Kenji; Yang, Cheng-Hsiung; Ooi, Hong-Kean

    2005-12-01

    A survey on the presence of Cryptosporidium oocyst and Giardia cyst in livestock drinking water as well as the urban tap water throughout Taiwan was carried out. Water examination for the presence of the protozoa was conducted by filtering through a PTFE membrane followed by immunomagnetic separation (IMS) and immunostaining the sediment with commercially available monoclonal antibody against Cryptosporidium and Giardia. Of the 55 different water samples from various sources examined, 2 were found to contain both of Cryptosporidium oocyst and Giardia cyst, 1 was found to contain Cryptosporidium oocyst only. These protozoa-positive water samples, originating from underground well and from the mountain spring, were also used as drinking water for livestock. However, no Cryptosporidium oocyst was found in the city tap water. This is the first report of Cryptosporidium oocyst and Giardia cyst being found in the drinking water for livestock.

  11. Analysis of iodide and iodate in Lake Mead, Nevada using a headspace derivatization gas chromatography-mass spectrometry.

    PubMed

    Dorman, James W; Steinberg, Spencer M

    2010-02-01

    We report here a derivatization headspace method for the analysis of inorganic iodine in water. Samples from Lake Mead, the Las Vegas Wash, and from Las Vegas tap water were examined. Lake Mead and the Las Vegas Wash contained a mixture of both iodide and iodate. The average concentration of total inorganic iodine (TII) for Lake Mead was approximately 90 nM with an iodide-to-iodate ratio of approximately 1. The TII concentration (approximately 160 nM) and the ratio of iodide to iodate were higher for the Las Vegas Wash (approximately 2). The TII concentration for tap water was close to that of Lake Mead (approximately 90 nM); however, tap water contained no detectable iodide as a result of ozonation and chlorine treatment which converts all of the iodide to iodate.

  12. Management of twin anemia-polycythemia sequence using intrauterine blood transfusion for the donor and partial exchange transfusion for the recipient.

    PubMed

    Genova, L; Slaghekke, F; Klumper, F J; Middeldorp, J M; Steggerda, S J; Oepkes, D; Lopriore, E

    2013-01-01

    Twin anemia-polycythemia sequence (TAPS) is a rare condition which may occur either spontaneously in uncomplicated monochorionic twin pregnancies or may develop after laser treatment in twin-twin transfusion syndrome. TAPS is characterized by a large intertwin discordance in hemoglobin levels without discordance in amniotic fluid levels, and may lead to severe complications including fetal hydrops, hematological morbidity and perinatal mortality. Several treatments have been proposed including intrauterine transfusion, laser surgery, elective delivery and expectant management. The optimal treatment remains unclear. In this case series we report 3 TAPS cases managed recently at our center with a combination of intrauterine blood transfusion for the anemic twin and intrauterine partial exchange transfusion for the polycythemic twin. In 1 case, the donor was found to have severe cerebral injury on neuroimaging examination. We propose etiologic mechanisms for cerebral injury in TAPS, discuss the rationale behind this treatment alternative, and evaluate the pros and cons of the various management options. Copyright © 2013 S. Karger AG, Basel.

  13. How does the duration of active pushing in labor affect neonatal outcomes?

    PubMed

    Yli, Branka M; Kro, Grete A Birkeland; Rasmussen, Svein; Khoury, Janette; Norèn, Håkan; Amer-Wåhlin, Isis; Saugstad, Ola Didrik; Stray-Pedersen, Babill

    2011-11-19

    To assess the effect of time of active pushing (TAP) on neonatal outcome. The study population (n=36,432) was taken from a Swedish randomized control trial on intrapartum monitoring, a European Union fetal electrocardiogram trial, and from Mölndal Hospital. After validation of acid-base samples and TAP, 22,812 cases were accepted for analysis. The median active TAP was 36 min for P0 and 13 min for P≥1 (P<0.001). After adjustments for parity, epidural, labor induction, birth weight, and gender, pushing for 15-29 min (n=6589) relative to pushing for <15 min (n=7264) increased the OR of a cord artery pH of <7.00 to 3.20 (95% CI 1.7-6.0), and that of a base deficit in extracellular fluid of >12 mmol/L to 3.5 (95% CI 1.3-9.0). The group with a cord artery pH of <7.00 had a longer TAP than the group with pH≥7.00: median (5th-95th percentile), 38 (9-107) min vs. 23 (5-87) min, P<0.001. The probability of a spontaneous vaginal delivery decreased significantly with every subsequent increase of 30 min in TAP (P<0.05). The risks of severe acidemia, metabolic acidosis, and deteriorated neonatal outcome gradually increased with the length of TAP (>15 min), while the probability of a spontaneous vaginal delivery decreased with the duration of pushing. We suggest active physiological evaluation of the labor progress together with continuous electronic fetal monitoring during pushing irrespective of guideline thresholds.

  14. ECONOMICS OF SAMPLE COMPOSITING AS A SCREENING TOOL IN GROUND WATER QUALITY MONITORING

    EPA Science Inventory

    Recent advances in high throughput/automated compositing with robotics/field-screening methods offer seldom-tapped opportunities for achieving cost-reduction in ground water quality monitoring programs. n economic framework is presented in this paper for the evaluation of sample ...

  15. Outbreak of viral gastroenteritis due to drinking water contaminated by Norwalk-like viruses.

    PubMed

    Kukkula, M; Maunula, L; Silvennoinen, E; von Bonsdorff, C H

    1999-12-01

    Heinävesi, a Finnish municipality with a population of 4860 inhabitants, had an outbreak of gastroenteritis in March 1998. On the basis of an epidemiologic survey, an estimated 1700-3000 cases of acute gastroenteritis occurred during the outbreak. Municipal water consumption was found to be associated with illness (risk ratio [RR]=3.5, 95% confidence interval, 3.11>RR>3.96). Norwalk-like virus (NLV) genogroup II (GGII) was identified in untreated water, treated water, and 4 tap water samples by use of reverse transcription-polymerase chain reaction. This was the first time NLVs had been detected in municipal tap water. Fifteen of 27 patient stool samples had NLV GGII, with an identical amplification product to that found in the water samples, indicating that the outbreak was caused by this virus. In some patients, NLV genogroup I was also encountered. This virus, however, could not be detected in the water samples. Inadequate chlorination contributed to the survival of the virus in the water.

  16. Nitrate, arsenic and chloride pollution of drinking water in Northern Greece. Elaboration by applying GIS.

    PubMed

    Fytianos, Konstantinos; Christophoridis, Christophoros

    2004-01-01

    The general profile of the pollution of drinking water, originating from groundwater, by nitrates, chloride and arsenic, in the Prefecture of Thessaloniki, was studied in this project. Samples (tap water) were collected from 52 areas-villages of the Prefecture, during a period of 6 months. The analytical results were related to certain points on the map of the area, thus producing coloured representations of the Prefecture, according to the concentration of the corresponding pollutant. The statistical analysis of the data led to some conclusions concerning the causes of pollution and the relation of the concentrations to certain physico-chemical parameters. Nitrate concentration of samples collected from two specific regions were especially high, sometimes above the highest permitted level. A limited number of samples (13.5%) contained arsenic concentrations above the imminent EC drinking water limit (10 ppb). The majority of the tap water samples, collected from areas along the seashore contained increased concentrations of chloride ions, which is a clear indication of seawater intrusion into the related aquifers.

  17. Financial and environmental modelling of water hardness--implications for utilising harvested rainwater in washing machines.

    PubMed

    Morales-Pinzón, Tito; Lurueña, Rodrigo; Gabarrell, Xavier; Gasol, Carles M; Rieradevall, Joan

    2014-02-01

    A study was conducted to determine the financial and environmental effects of water quality on rainwater harvesting systems. The potential for replacing tap water used in washing machines with rainwater was studied, and then analysis presented in this paper is valid for applications that include washing machines where tap water hardness may be important. A wide range of weather conditions, such as rainfall (284-1,794 mm/year); water hardness (14-315 mg/L CaCO3); tap water prices (0.85-2.65 Euros/m(3)) in different Spanish urban areas (from individual buildings to whole neighbourhoods); and other scenarios (including materials and water storage capacity) were analysed. Rainfall was essential for rainwater harvesting, but the tap water prices and the water hardness were the main factors for consideration in the financial and the environmental analyses, respectively. The local tap water hardness and prices can cause greater financial and environmental impacts than the type of material used for the water storage tank or the volume of the tank. The use of rainwater as a substitute for hard water in washing machines favours financial analysis. Although tap water hardness significantly affects the financial analysis, the greatest effect was found in the environmental analysis. When hard tap water needed to be replaced, it was found that a water price of 1 Euro/m(3) could render the use of rainwater financially feasible when using large-scale rainwater harvesting systems. When the water hardness was greater than 300 mg/L CaCO3, a financial analysis revealed that an net present value greater than 270 Euros/dwelling could be obtained at the neighbourhood scale, and there could be a reduction in the Global Warming Potential (100 years) ranging between 35 and 101 kg CO2 eq./dwelling/year. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Assessment of trace elements in terminal tap water of Hunan Province, South China, and the potential health risks.

    PubMed

    Li, Mansha; Du, Yong; Chen, Lv; Liu, Lulu; Duan, Yanying

    2018-05-02

    A total of 116 terminal tap water (TTW) samples from Xiangjiang, Zijiang, Yuanjiang, and Lishui river basins of Hunan province were collected and concentrations of As, Cd, Cr, Pb, Mn, Zn, Fe, Al, and Cu were determined using inductively coupled plasma mass spectrometry. The results showed that 10% of the water samples exceeded the limit level of Cd established by World Health Organization (WHO) of 0.003 mg L -1 . Three percent of the samples had Fe level and 1% had As level above the WHO limits of 0.3 and 0.01 mg L -1 , respectively. Multivariate statistic approach (cluster analysis and principal component analysis) results revealed that anthropogenic activities and pipeline corrosion were major sources of TTW contamination in Hunan province. The individual and total hazard quotient values estimated by deterministic and probabilistic approaches were both less than 1. However, the mean cancer risk values of Cd were 2.2 × 10 -4 and 1.4 × 10 -4 for Xiangjiang and Yuanjiang river basin, respectively, both greater than 10 -4 . The 95th percentile value of cancer risk for Cr was slightly greater than 10 -4 in Xiangjiang river basins. Long-term exposure to Cd and Cr through tap water consumption poses moderate carcinogenic health risks to the local residents.

  19. Is Exposure to Tobacco Advertising, Promotion and Sponsorship Associated with Initiation of Tobacco Use among Current Tobacco Users in Youth in India?

    PubMed

    Sardana, Mohini; Goel, Sonu; Gupta, Madhu; Sardana, Veera; Singh, B S

    2015-01-01

    The rise in consumption of tobacco products among youth is a public health concern in India. Several studies have shown that advertisements promoting tobacco products influence decisions and behaviour of youth towards smoking. To ascertain which method of Tobacco Advertising, Promotion and Sponsorship (TAPS) was more influential for initiating tobacco use in youth in India. The secondary data of youth (15-24 years) from nationally representative Global Adult Tobacco Survey (GATS) conducted in 2009-2010 was analyzed. Odds ratio and p-value were used to know the association between TAPS and initiation of use of tobacco products among youth. Logistic regression was used to determine the most significant means of TAPS altering the youth's behaviour towards tobacco products. Out of 13,383 youths, 1,982 (14.7%) used smokeless forms of tobacco and 860 (6.38%) used smoke forms. Logistic regression reveals that promotional activities mainly through cinemas (p<0.05) and providing free samples of tobacco products (p<=.001) were most influential means of initiating consumption of tobacco products among youth. The smoking in youth is associated with watching advertisements particularly in cinema and promotional activities like distribution of free samples, coupons and sales on the price of tobacco products. Stronger legislative measures should be enforced to curb promotional advertisements in cinemas and distribution of free samples.

  20. Relation of dietary inorganic arsenic to serum matrix metalloproteinase-9 (MMP-9) at different threshold concentrations of tap water arsenic

    PubMed Central

    Kurzius-Spencer, Margaret; Harris, Robin B.; Hartz, Vern; Roberge, Jason; Hsu, Chiu-Hsieh; O’Rourke, Mary Kay; Burgess, Jefferey L.

    2015-01-01

    Arsenic (As) exposure is associated with cancer, lung and cardiovascular disease, yet the mechanisms involved are not clearly understood. Elevated matrix metalloproteinase-9 (MMP-9) levels are also associated with these diseases, as well as with exposure to water As. Our objective was to evaluate the effects of dietary components of inorganic As (iAs) intake on serum MMP-9 concentration at differing levels of tap water As. In a cross-sectional study of 214 adults, dietary iAs intake was estimated from 24-h dietary recall interviews using published iAs residue data; drinking and cooking water As intake from water samples and consumption data. Aggregate iAs intake (food plus water) was associated with elevated serum MMP-9 in mixed model regression, with and without adjustment for covariates. In models stratified by tap water As, aggregate intake was a significant positive predictor of serum MMP-9 in subjects exposed to water As ≤10 μg/l. Inorganic As from food alone was associated with serum MMP-9 in subjects exposed to tap water As ≤3 μg/l. Exposure to iAs from food and water combined, in areas where tap water As concentration is ≤10 μg/l, may contribute to As-induced changes in a biomarker associated with toxicity. PMID:25605447

  1. Analysis of UV filters in tap water and other clean waters in Spain.

    PubMed

    Díaz-Cruz, M Silvia; Gago-Ferrero, Pablo; Llorca, Marta; Barceló, Damià

    2012-03-01

    The present paper describes the development of a method for the simultaneous determination of five hormonally active UV filters namely benzophenone-3 (BP3), 3-(4-methylbenzylidene) camphor (4MBC), 2-ethylhexyl 4-(dimethylamino) benzoate (OD-PABA), 2-ethylhexyl 4-methoxycinnamate (EHMC) and octocrylene (OC) by means of solid-phase extraction and gas chromatography-electron impact ionization-mass spectrometry. Under optimized conditions, this methodology achieved low method limits of detection (needed for clean waters, especially drinking water analysis), between 0.02 and 8.42 ng/L, and quantitative recovery rates higher than 73% in all cases. Inter- and intraday precision for all compounds were lower than 7% and 11%, respectively. The optimized methodology was applied to perform the first survey of UV absorbing compounds in tap water from the metropolitan area and the city of Barcelona (Catalonia, Spain). In addition, other types of clean water matrices (mineral bottled water, well water and tap water treated with an ion-exchange resin) were investigated as well. Results evidenced that all the UV filters investigated were detected in the water samples analyzed. The compounds most frequently found were EHMC and OC. Maximum concentrations reached in tap water were 290 (BP3), 35 (4MBC), 110 (OD-PABA), 260 (EHMC), and 170 ng/L (OC). This study constitutes the first evidence of the presence of UV filter residues in tap water in Europe.

  2. A tapping device for recording and quantitative characterization of rhythmic/auditory sequences.

    PubMed

    Piazza, Caterina; Cesareo, Ambra; Caccia, Martina; Reni, Gianluigi; Lorusso, Maria L

    2017-07-01

    The processing of auditory stimuli is essential for the correct perception of language and deficits in this ability are often related to the presence or development of language disorders. The motor imitation (e.g. tapping or beating) of rhythmic sequences can be a very sensitive correlate of deficits in auditory processing. Thus, the study of the tapping performance, with the investigation of both temporal and intensity information, might be very useful. The present work is aimed at the development and preliminary testing of a tapping device to be used for the imitation and/or the production of rhythmic sequences, allowing the recording of both tapping duration and intensity. The device is essentially made up of a Force Sensing Resistor and an Arduino UNO board. It was validated using different sampling frequencies (f s ) in a group of 10 young healthy adults investigating its efficacy in terms of touch and intensity detection by means of two testing procedures. Results demonstrated a good performance of the device when programmed with fs equal to 50 and 100Hz. Moreover, both temporal and intensity parameters were extracted, thus supporting the potential use of the device for the analysis of the imitation or production of rhythmic sequences. This work represents a first step for the development of a useful, low cost tool to support the diagnosis, training and rehabilitation of language disorders.

  3. Detecting drug-target binding in cells using fluorescence-activated cell sorting coupled with mass spectrometry analysis.

    PubMed

    Wilson, Kris; Webster, Scott P; Iredale, John P; Zheng, Xiaozhong; Homer, Natalie Z; Pham, Nhan T; Auer, Manfred; Mole, Damian J

    2017-12-15

    The assessment of drug-target engagement for determining the efficacy of a compound inside cells remains challenging, particularly for difficult target proteins. Existing techniques are more suited to soluble protein targets. Difficult target proteins include those with challenging in vitro solubility, stability or purification properties that preclude target isolation. Here, we report a novel technique that measures intracellular compound-target complex formation, as well as cellular permeability, specificity and cytotoxicity-the toxicity-affinity-permeability-selectivity (TAPS) technique. The TAPS assay is exemplified here using human kynurenine 3-monooxygenase (KMO), a challenging intracellular membrane protein target of significant current interest. TAPS confirmed target binding of known KMO inhibitors inside cells. We conclude that the TAPS assay can be used to facilitate intracellular hit validation on most, if not all intracellular drug targets.

  4. Detecting drug-target binding in cells using fluorescence-activated cell sorting coupled with mass spectrometry analysis

    NASA Astrophysics Data System (ADS)

    Wilson, Kris; Webster, Scott P.; Iredale, John P.; Zheng, Xiaozhong; Homer, Natalie Z.; Pham, Nhan T.; Auer, Manfred; Mole, Damian J.

    2018-01-01

    The assessment of drug-target engagement for determining the efficacy of a compound inside cells remains challenging, particularly for difficult target proteins. Existing techniques are more suited to soluble protein targets. Difficult target proteins include those with challenging in vitro solubility, stability or purification properties that preclude target isolation. Here, we report a novel technique that measures intracellular compound-target complex formation, as well as cellular permeability, specificity and cytotoxicity-the toxicity-affinity-permeability-selectivity (TAPS) technique. The TAPS assay is exemplified here using human kynurenine 3-monooxygenase (KMO), a challenging intracellular membrane protein target of significant current interest. TAPS confirmed target binding of known KMO inhibitors inside cells. We conclude that the TAPS assay can be used to facilitate intracellular hit validation on most, if not all intracellular drug targets.

  5. Analysis of antithyroid drugs in surface water by using liquid chromatography-tandem mass spectrometry.

    PubMed

    Pérez-Fernández, Virginia; Marchese, Stefano; Gentili, Alessandra; García, María Ángeles; Curini, Roberta; Caretti, Fulvia; Perret, Daniela

    2014-11-07

    This paper describes development and validation of a new method for the simultaneous determination of six antithyroid drugs (ATDs) in surface waters by using liquid chromatography-triple quadrupole mass spectrometry (LC-MS/MS). Target compounds include two ATD classes: thiouracil derivatives (thiouracil (TU), methyl-thiouracil (MTU), propyl-thiouracil (PTU), phenyl-thiouracil (PhTU)) and imidazole derivatives (tapazole (TAP), and mercaptobenzimidazole (MBI)). Sensitivity and selectivity of the LC-multiple reaction monitoring (MRM) analysis allowed applying a simple pre-concentration procedure and "shooting" the concentrated sample into the LC-MS/MS system without any other treatment. Recoveries were higher than 75% for all analytes. Intra-day precision and inter-day precision, calculated as relative standard deviation (RSD), were below 19 and 22%, respectively. Limits of detection (LODs) ranged from 0.05 to 0.25 μg/L; limits of quantitation (LOQs) varied between 0.15 and 0.75 μg/L. The validated method was successfully applied to the analysis of ATD residues in surface water samples collected from the Tiber River basin and three lakes of Lazio (central Italy). The analytes were quantified based on matrix-matched calibration curves with mercaptobenzimidazole-d4 (MBI-d4) as the internal standard (IS). The most widespread compound was TAP, one of the most common ATDs used in human medicine, but also TU and MBI were often detected in the analysed samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Stir bar sorptive extraction and liquid chromatography-tandem mass spectrometry determination of polar and non-polar emerging and priority pollutants in environmental waters.

    PubMed

    Aparicio, Irene; Martín, Julia; Santos, Juan Luis; Malvar, José Luis; Alonso, Esteban

    2017-06-02

    An analytical method based on stir bar sorptive extraction (SBSE) was developed and validated for the determination of environmental concern pollutants in environmental waters by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Target compounds include six water and oil repellents (perfluorinated compounds), four preservatives (butylated hydroxytoluene and three parabens), two plasticizers (bisphenol A and di(2-ethylhexyl)phthalate), seven surfactants (four linear alkylbenzene sulfonates, nonylphenol and two nonylphenol ethoxylates), a flame retardant (hexabromocyclododecane), four hormones, fourteen pharmaceutical compounds, an UV-filter (2-ethylhexyl 4-methoxycinnamate) and nine pesticides. To achieve the simultaneous extraction of polar and non-polar pollutants two stir bar coatings were tested, the classic polydimethylsiloxane (PDMS) coating and the novel ethylene glycol modified silicone (EG-silicone). The best extraction recoveries were obtained using EG-silicone coating. The effects of sample pH, volume and ionic strength and extraction time on extraction recoveries were evaluated. The analytical method was validated for surface water and tap water samples. The method quantification limits ranged from 7.0ngL -1 to 177ngL -1 . The inter-day precision, expressed as relative standard deviation, was lower than 20%. Accuracy, expressed as relative recovery values, was in the range from 61 to 130%. The method was applied for the determination of the 48 target compounds in surface and tap water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. NHEXAS PHASE I ARIZONA STUDY--METALS IN WATER ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Water data set contains analytical results for measurements of up to 11 metals in 314 water samples over 211 households. Sample collection was undertaken at the tap and any additional drinking water source used extensively within each residence. The primary metals...

  8. Bacteria-free water for automatic washer-disinfectors: an impossible dream?

    PubMed

    Cooke, R P; Whymant-Morris, A; Umasankar, R S; Goddard, S V

    1998-05-01

    The ability of a new automatic washer-disinfector system (AWDS), fitted with a water filtration system to provide bacteria-free water and so avoid the risk of mycobacterial contamination of fibreoptic bronchoscopes, was examined. Four new Astec 'MP' Safescope washer-disinfectors, with coarse and fine (0.2 micron) filters attached close to the outlet taps, were supplied with non-softened mains water. Water samples from the tank supply and outlet taps were regularly assessed for bacterial quality over a six-month period. Outlet samples were also analysed after fine filter change and purgation with peracetic acid. All bronchoalveolar lavage specimens (BALS) were stained and cultured for mycobacteria. Only 13 out of 53 outlet samples (24%) were culture-negative. There was no improvement after filter change. Residual anti-bacterial effect of peracetic acid lasted up to 48 h following AWDS purgation. No tank samples were bacteria-free. Sixty BALS were processed, two samples were culture-positive and grew M. tuberculosis and one was also smear-positive. Though mycobacterial contamination of bronchoscopes was not evident, the water filtration system was unable to reliably provide sterile rinse water.

  9. Determination of microcystin-LR in drinking water using UPLC tandem mass spectrometry-matrix effects and measurement.

    PubMed

    Li, Wei; Duan, Jinming; Niu, Chaoying; Qiang, Naichen; Mulcahy, Dennis

    2011-10-01

    A simple detection method using ultra-performance liquid chromatography electrospray ionisation tandem mass spectrometry (UPLC-ESI-MS-MS) coupled with the sample dilution method for determining trace microcystin-LR (MC-LR) in drinking water is presented. The limit of detection (LOD) was 0.04 µg/L and the limit of quantitation (LOQ) was 0.1 µg/L. Water matrix effects of ionic strength, dissolved organic carbon (DOC) and pH were examined. The results indicate that signal detection intensity for MC-LR was significantly suppressed as the ionic strength increased from ultrapure water condition, whereas it increased slightly with solution pH and DOC at low concentrations. However, addition of methanol (MeOH) into the sample was able to counter the signal suppression effects. In this study, dilution of the tap water sample by adding 4% MeOH (v/v) was observed to be adequate to compensate for the signal suppression. The recoveries of the samples fortified with MC-LR (0.2, 1, and 10 µg/L) for three different tap water samples ranged from 84.4% to 112.9%.

  10. Prediction of the severity of acute pancreatitis on admission by urinary trypsinogen activation peptide: A meta-analysis

    PubMed Central

    Huang, Wei; Altaf, Kiran; Jin, Tao; Xiong, Jun-Jie; Wen, Li; Javed, Muhammad A; Johnstone, Marianne; Xue, Ping; Halloran, Christopher M; Xia, Qing

    2013-01-01

    AIM: To undertake a meta-analysis on the value of urinary trypsinogen activation peptide (uTAP) in predicting severity of acute pancreatitis on admission. METHODS: Major databases including Medline, Embase, Science Citation Index Expanded and the Cochrane Central Register of Controlled Trials in the Cochrane Library were searched to identify all relevant studies from January 1990 to January 2013. Pooled sensitivity, specificity and the diagnostic odds ratios (DORs) with 95%CI were calculated for each study and were compared to other systems/biomarkers if mentioned within the same study. Summary receiver-operating curves were conducted and the area under the curve (AUC) was evaluated. RESULTS: In total, six studies of uTAP with a cut-off value of 35 nmol/L were included in this meta-analysis. Overall, the pooled sensitivity and specificity of uTAP for predicting severity of acute pancreatitis, at time of admission, was 71% and 75%, respectively (AUC = 0.83, DOR = 8.67, 95%CI: 3.70-20.33). When uTAP was compared with plasma C-reactive protein, the pooled sensitivity, specificity, AUC and DOR were 0.64 vs 0.67, 0.77 vs 0.75, 0.82 vs 0.79 and 6.27 vs 6.32, respectively. Similarly, the pooled sensitivity, specificity, AUC and DOR of uTAP vs Acute Physiology and Chronic Health Evaluation II within the first 48 h of admission were found to be 0.64 vs 0.69, 0.77 vs 0.61, 0.82 vs 0.73 and 6.27 vs 4.61, respectively. CONCLUSION: uTAP has the potential to act as a stratification marker on admission for differentiating disease severity of acute pancreatitis. PMID:23901239

  11. Forty years of temporal analysis of products

    DOE PAGES

    Morgan, K.; Maguire, N.; Fushimi, R.; ...

    2017-05-16

    Detailed understanding of mechanisms and reaction kinetics are required in order to develop and optimize catalysts and catalytic processes. While steady state investigations are known to give a global view of the catalytic system, transient studies are invaluable since they can provide more detailed insight into elementary steps. For almost thirty years temporal analysis of products (TAP) has been successfully utilized for transient studies of gas phase heterogeneous catalysis, and there have been a number of advances in instrumentation and numerical modeling methods in that time. In the current work, the range of available TAP apparatus will be discussed whilemore » detailed explanations of the types of TAP experiment, the information that can be determined from these experiments and the analysis methods are also included. TAP is a complex methodology and is often viewed as a niche specialty. Here, part of the intention of this work is to highlight the significant contributions TAP can make to catalytic research, while also discussing the issues which will make TAP more relevant and approachable to a wider segment of the catalytic research community. With this in mind, an outlook is also disclosed for the technique in terms of what is needed to revitalize the field and make it more applicable to the recent advances in catalyst characterization (e.g. operando modes).« less

  12. Forty years of temporal analysis of products

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morgan, K.; Maguire, N.; Fushimi, R.

    Detailed understanding of mechanisms and reaction kinetics are required in order to develop and optimize catalysts and catalytic processes. While steady state investigations are known to give a global view of the catalytic system, transient studies are invaluable since they can provide more detailed insight into elementary steps. For almost thirty years temporal analysis of products (TAP) has been successfully utilized for transient studies of gas phase heterogeneous catalysis, and there have been a number of advances in instrumentation and numerical modeling methods in that time. In the current work, the range of available TAP apparatus will be discussed whilemore » detailed explanations of the types of TAP experiment, the information that can be determined from these experiments and the analysis methods are also included. TAP is a complex methodology and is often viewed as a niche specialty. Here, part of the intention of this work is to highlight the significant contributions TAP can make to catalytic research, while also discussing the issues which will make TAP more relevant and approachable to a wider segment of the catalytic research community. With this in mind, an outlook is also disclosed for the technique in terms of what is needed to revitalize the field and make it more applicable to the recent advances in catalyst characterization (e.g. operando modes).« less

  13. p53 and TAp63 Promote Keratinocyte Proliferation and Differentiation in Breeding Tubercles of the Zebrafish

    PubMed Central

    Fischer, Boris; Metzger, Manuel; Richardson, Rebecca; Knyphausen, Philipp; Ramezani, Thomas; Franzen, Rainer; Schmelzer, Elmon; Bloch, Wilhelm; Carney, Thomas J.; Hammerschmidt, Matthias

    2014-01-01

    p63 is a multi-isoform member of the p53 family of transcription factors. There is compelling genetic evidence that ΔNp63 isoforms are needed for keratinocyte proliferation and stemness in the developing vertebrate epidermis. However, the role of TAp63 isoforms is not fully understood, and TAp63 knockout mice display normal epidermal development. Here, we show that zebrafish mutants specifically lacking TAp63 isoforms, or p53, display compromised development of breeding tubercles, epidermal appendages which according to our analyses display more advanced stratification and keratinization than regular epidermis, including continuous desquamation and renewal of superficial cells by derivatives of basal keratinocytes. Defects are further enhanced in TAp63/p53 double mutants, pointing to partially redundant roles of the two related factors. Molecular analyses, treatments with chemical inhibitors and epistasis studies further reveal the existence of a linear TAp63/p53->Notch->caspase 3 pathway required both for enhanced proliferation of keratinocytes at the base of the tubercles and their subsequent differentiation in upper layers. Together, these studies identify the zebrafish breeding tubercles as specific epidermal structures sharing crucial features with the cornified mammalian epidermis. In addition, they unravel essential roles of TAp63 and p53 to promote both keratinocyte proliferation and their terminal differentiation by promoting Notch signalling and caspase 3 activity, ensuring formation and proper homeostasis of this self-renewing stratified epithelium. PMID:24415949

  14. Benefit Estimates of Terminal Area Productivity Program Technologies

    NASA Technical Reports Server (NTRS)

    Hemm, Robert; Shapiro, Gerald; Lee, David; Gribko, Joana; Glaser, Bonnie

    1999-01-01

    This report documents benefit analyses for the NASA Terminal Area Technology (TAP) technology programs. Benefits are based on reductions in arrival delays at ten major airports over the 10 years from 2006 through 2015. Detailed analytic airport capacity and delay models were constructed to produce the estimates. The goal of TAP is enable good weather operations tempos in all weather conditions. The TAP program includes technologies to measure and predict runway occupancy times, reduce runway occupancy times in bad weather, accurately predict wake vortex hazards, and couple controller automation with aircraft flight management systems. The report presents and discusses the estimate results and describes the models. Three appendixes document the model algorithms and discuss the input parameters selected for the TAP technologies. The fourth appendix is the user's guide for the models. The results indicate that the combined benefits for all TAP technologies at all 10 airports range from $550 to $650 million per year (in constant 1997 dollars). Additional benefits will accrue from reductions in departure delays. Departure delay benefits are calculated by the current models.

  15. Dispersive liquid-liquid microextraction method based on solidification of floating organic droplet for the determination of thiamphenicol and florfenicol in environmental water samples.

    PubMed

    Peng, Guilong; He, Qiang; Al-Hamadani, Sulala M Z F; Zhou, Guangming; Liu, Mengzi; Zhu, Hui; Chen, Junhua

    2015-05-01

    Dispersive liquid-liquid microextraction with solidification of a floating organic droplet (DLLME-SFO) followed by high performance liquid chromatography-ultraviolet (HPLC-UV) detection was applied for the determination of thiamphenicol (TAP), florfenicol (FF) in water samples. 1-Undecanol was used as the extraction solvent which has lower density than water, low toxicity, and low melting point (19°C). A mixture of 800mL acetone (disperser solvent) and 80µL of 1-undecanol (extraction solvent) was injected into 20mL of aqueous solution. After 5min, 0.6g of NaCl was added and the sample vial was shaken. After 5min, the sample was centrifuged at 3500rpm for 3min, and then placed in an ice bath. When the extraction solvent floating on the aqueous solution had solidified, it was transferred into another conical vial where it was melted quickly at room temperature, and was diluted with methanol to 1mL, and analyzed by HPLC-UV detection. Parameters influencing the extraction efficiency were thoroughly examined and optimized. The extraction recoveries (ER) and the enrichment factors (EF) ranged from 67% to 72% and 223 to 241, respectively. The limits of detection (LODs) (S/N=3) were 0.33 and 0.56µgL(-1) for TAP and FF, respectively. Linear dynamic range (LDR) was in the range of 1.0-550µgL(-1) for TAP and 1.5-700µgL(-1) for FF, the relative standard deviations (RSDs) were in the range of 2.6-3.5% and the recoveries of spiked samples ranged from 94% to 106%. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Optimizing laser crater enhanced Raman spectroscopy.

    PubMed

    Lednev, V N; Sdvizhenskii, P A; Grishin, M Ya; Filichkina, V A; Shchegolikhin, A N; Pershin, S M

    2018-03-20

    Raman signal enhancement by laser crater production was systematically studied for 785 nm continuous wave laser pumping. Laser craters were produced in L-aspartic acid powder by a nanosecond pulsed solid state neodymium-doped yttrium aluminum garnet laser (532 nm, 8 ns, 1 mJ/pulse), while Raman spectra were then acquired by using a commercial spectrometer with 785 nm laser beam pumping. The Raman signal enhancement effect was studied in terms of the number of ablating pulses used, the lens-to-sample distance, and the crater-center-laser-spot offset. The influence of the experiment parameters on Raman signal enhancement was studied for different powder materials. Maximum Raman signal enhancement reached 11 fold for loose powders but decreased twice for pressed tablets. Raman signal enhancement was demonstrated for several diverse powder materials like gypsum or ammonium nitrate with better results achieved for the samples tending to give narrow and deep craters upon the laser ablation stage. Alternative ways of cavity production (steel needle tapping and hole drilling) were compared with the laser cratering technique in terms of Raman signal enhancement. Drilling was found to give the poorest enhancement of the Raman signal, while both laser ablation and steel needle tapping provided comparable results. Here, we have demonstrated for the first time, to the best of our knowledge, that a Raman signal can be enhanced 10 fold with the aid of simple cavity production by steel needle tapping in rough highly reflective materials. Though laser crater enhancement Raman spectroscopy requires an additional pulsed laser, this technique is more appropriate for automatization compared to the needle tapping approach.

  17. Altered Expression of TAP-1 and Major Histocompatibility Complex Class I in Laryngeal Papillomatosis: Correlation of TAP-1 with Disease

    PubMed Central

    Vambutas, Andrea; Bonagura, Vincent R.; Steinberg, Bettie M.

    2000-01-01

    Recurrent respiratory papillomatosis (RRP) is an insidious disease caused by human papillomavirus (HPV) infection. It is characterized by a variable clinical course that can include frequent disease recurrence, significant morbidity, and occasional mortality. The mechanisms responsible for the variability in the clinical course and the persistence of latent HPV infection remain unknown. Effective T-cell-mediated clearance of HPV-infected cells may be defective in patients with RRP, leading to recurrent disease and failure to suppress latent HPV reactivation. This study describes the down-regulation of the transporter associated with antigen presentation (TAP-1) and the major histocompatibility complex (MHC) class I protein expression in laryngeal papilloma tissue biopsies and cell culture of primary explants. There was a statistically significant correlation between reduction of TAP-1 expression in biopsy tissues and rapid recurrence of disease. Patients with RRP had less frequent recurrence if their papillomas expressed TAP-1 at levels close to that of normal tissue, compared with those with very low expression of TAP-1, who had frequent recurrence (32 versus 5 weeks to the next surgical intervention). These findings suggest that HPV may evade immune recognition by down-regulating class I MHC cell surface expression via decreased TAP-1 levels. Expression of TAP-1 could be used for prognostic evaluation of disease severity. Gamma interferon was able to restore class I MHC expression at the surfaces of laryngeal papilloma cells in culture. This up-regulation of class I MHC antigen at the cell surface potentially allows the infected cell to become a target for the immune system again. This finding provides some promise for nonsurgical treatment of laryngeal papillomas. PMID:10618282

  18. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN WATER ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Water data set contains analytical results for measurements of up to 11 metals in 98 water samples over 61 households. Sample collection was undertaken at the tap and any additional drinking water source used extensively within each residence. The primary metals o...

  19. ARSENIC URINARY METABOLITES: BIOMARKER STUDY

    EPA Science Inventory

    A population of adults and children with ranges of 10 to 300 g/l of arsenic in their drinking water will have their urine analyzed for total and speciated arsenic. A sample of 30 families will be selected based on tap water analyses for arsenic. This sample will comprise 50% adul...

  20. Detection of chlorinated and brominated byproducts of drinking water disinfection using electrospray ionization-high-field asymmetric waveform ion mobility spectrometry-mass spectrometry.

    PubMed

    Ells, B; Barnett, D A; Froese, K; Purves, R W; Hrudey, S; Guevremont, R

    1999-10-15

    The lower limit of detection for low molecular weight polar and ionic analytes using electrospray ionization-mass spectrometry (ESI-MS) is often severely compromised by an intense background that obscures ions of trace components in solution. Recently, a new technique, referred to as high-field asymmetric waveform ion mobility spectrometry (FAIMS), has been shown to separate gas-phase ions at atmospheric pressure and room temperature. A FAIMS instrument is an ion filter that may be tuned, by control of electrical voltages, to continuously transmit selected ions from a complex mixture. This capability offers significant advantages when FAIMS is coupled with ESI, a source that generates a wide variety of ions, including solvent clusters and salt adducts. In this report, the tandem arrangement of ESI-FAIMS-MS is used for the analysis of haloacetic acids, a class of disinfection byproducts regulated by the US EPA. FAIMS is shown to effectively discriminate against background ions resulting from the electrospray of tap water solutions containing the haloacetic acids. Consequently, mass spectra are simplified, the selectivity of the method is improved, and the limits of detection are lowered compared with conventional ESI-MS. The detection limits of ESI-FAIMS-MS for six haloacetic acids ranged between 0.5 and 4 ng/mL in 9:1 methanol/tap water (5 and 40 ng/mL in the original tap water samples) with no preconcentration, derivatization, or chromatographic separation prior to analysis.

  1. Torsional tapping atomic force microscopy for molecular resolution imaging of soft matter

    NASA Astrophysics Data System (ADS)

    Hobbs, Jamie; Mullin, Nic

    2012-02-01

    Despite considerable advances in image resolution on challenging, soft systems, a method for obtaining molecular resolution on `real' samples with significant surface roughness has remained elusive. Here we will show that a relatively new technique, torsional tapping AFM (TTAFM), is capable of imaging with resolution down to 3.7 Angrstrom on the surface of `bulk' polymer films [1]. In TTAFM T-shaped cantilevers are driven into torsional oscillation. As the tip is offset from the rotation axis this provides a tapping motion. Due to the high frequency and Q of the oscillation and relatively small increase in spring constant, improved cantilever dynamics and force sensitivity are obtained. As the tip offset from the torsional axis is relatively small (typically 25 microns), the optical lever sensitivity is considerably improved compared to flexural oscillation. Combined these give a reduction in noise floor by a factor of 12 just by changing the cantilever geometry. The ensuing low noise allows the use of ultra-sharp `whisker' tips with minimal blunting. As the cantilevers remain soft in the flexural axis, the force when imaging with error is also reduced, further protecting the tip. We will show that this combination allows routine imaging of the molecular structure of semicrystalline polymer films, including chain folds, loose loops and tie-chains in polyethylene, and the helical conformation of polypropylene within the crystal, using a standard, commercial AFM. [4pt] [1] N Mullin, JK Hobbs, PRL 107, 197801 (2011)

  2. Into hot water head first: distribution of intentional and unintentional immersion burns.

    PubMed

    Daria, Sonya; Sugar, Naomi F; Feldman, Kenneth W; Boos, Stephen C; Benton, Scott A; Ornstein, Amy

    2004-05-01

    Experience with several, previously unreported, intentional face-first immersion burns led us to evaluate the distribution of inflicted and unintentional immersion scald burns in a hospital series. (1) Authors' clinical and legal practices; (2) Burn center at regional Level 1 trauma hospital. : (1) Case series of face-first, inflicted immersion burn victims; (2) Consecutive hospitalized scald burn victims younger than 5 years old, 1/3/1996 to 3/25/2000. (1) Individual case reports; (2) Retrospective records review. Simple descriptive statistics, Fisher Exact test and t test. (1) Six cases of inflicted head and neck immersion injury are described. Four were tap water and 2 food/drink scalds. (2) 22/195 hospitalized victims had sustained immersion burns, 13 from tap water and 9 from other fluids. Six (46%) tap water immersions and no (0%) other immersions had inflicted injuries (P = 0.05). Two of the tap water immersions and one other source immersion included burning of the head and neck. Of these, one tap water immersion, but no other immersion, was inflicted. In no patients were head and neck injuries the sole or predominant site of scalding. In all, 9 children sustained inflicted scalds. Bilateral lower extremity tap water immersion scalds occurred in 100% (6/6) of abusive and 29% (2/7) of unintentional injuries (P = 0.02). Buttock and perineal injuries occurred in 67% (4/6) inflicted versus 29% (2/7) unintentional tap water immersion scalds (P = 0.28). Other fluids caused bilateral lower extremity immersion burns in 3/9 (33 %) unintentionally injured patients, but no abused children (NS). Craniofacial immersion injury, although seen by the authors in legal cases, is infrequent. It was present incidentally in one inflicted tap water burn in the consecutive hospital series. This series affirms the predominance of bilateral lower extremity burns in inflicted tap water immersions. Buttock/perineal immersions were more common with abuse than with unintentional injury.

  3. The distribution of bromide in water in the Floridan aquifer system, Duval County, northeastern Florida

    USGS Publications Warehouse

    German, E.R.; Taylor, G.F.

    1995-01-01

    Although Duval County, Florida, has ample ground-water resources for public supply, the potential exists for a problem with excessive disinfectant by-products. These disinfectant by-products result from the treatment of raw water containing low concentrations of bromide and naturally occurring organic compounds. Because of this potential problem, the relation of bromide concentrations to aquifer tapped, well location and depth, and chemical characteristics of water in the Floridan aquifer system underlying Duval County were studied to determine if these relations could be applied to delineate water with low-bromide concentrations for future supplies. In 1992, water samples from 106 wells that tap the Floridan aquifer system were analyzed for bromide and major dissolved constituents. A comparison of bromide concentrations from the 1992 sampling with data from earlier studies (1979-80) indicates that higher bromide concentrations were detected during the earlier studies. The difference between the old and new data is probably because of a change in analytical methodology in the analysis of samples. Bromide concentrations exceeded the detection limit (0.10 milligrams per liter) in water from 28 of the 106 wells (26 percent) sampled in 1992. The maximum concentration was 0.56 milligrams per liter. There were no relations between bromide and major dissolved constituents, well depth, or aquifer tapped that would be useful for determining bromide concentrations. Areal patterns of bromide occurrence are not clearly defined, but areas with relatively high bromide concentrations tend to be located in a triangular area near the community of Sunbeam, Florida, and along the St. Johns River throughout Duval County.

  4. Effect of yoghurt or yoghurt serum on microbial quality of cig kofte.

    PubMed

    Dogan, Mahmut; Cankurt, Hasan; Toker, Omer Said; Yetim, Hasan; Sagdic, Osman

    2014-07-01

    Cig kofte, raw meatball is a traditionally produced meat product in Turkey and some other Middle East countries. It is prepared from mixtures of finely minced raw beef, bulgur, onions, various spices and tap water. Cig kofte is an uncooked product and popularly consumed with lettuce and lemon juice. In this study, yoghurt or yoghurt serum (YS) were added to the mixtures of cig kofte instead of tap water to reduce microbial risks of the raw meatball. Additionally, the effects of yoghurt and YS on some physicochemical characteristics of cig kofte were investigated. Cig kofte is generally consumed within a few hours after the preparation because of its raw nature. Also, it is generally sold under unhygienic conditions in restaurants and restaurant-like places. For this purpose, reducing of the microbial load of cig kofte is important. In the results, Escherichia coli and Listeria monocytogenes were not detected in any samples. While lactic acid bacteria count increased by addition of yoghurt and YS, the number of other microorganisms except for total aerobic mesophilic bacteria (TAMB) were decreased. The aw values and% moisture contents of the samples were varied between 0.88-0.94 and 46.25-49.72, respectively. The pH values of the samples were slightly changed during the storage of 24 h while no changes detected in the control samples during the storage. In conclusion, it can be suggested that using the yoghurt or YS instead of tap water in the preparation of cig kofte might ensure the microbial safety, increase the nutritional value and its flavour or aroma.

  5. On-tap passive enrichment, a new way to investigate off-flavor episodes in drinking water.

    PubMed

    Tondelier, Christophe; Thouvenot, Thomas; Genin, Arnaud; Benanou, David

    2009-04-03

    Because taste and odor events in drinking water are often fleeting and unpredictable phenomena, an innovative enrichment sampler has been developed to trap off-flavor compounds directly at the consumer's tap. The ARISTOT (Advanced Relevant Investigation Sampler for Taste & Odor at Tap) consists of a tap adapter in which seven polydimethylsiloxane (PDMS) coated stir bars are placed, allowing the stir bar sorptive extraction (SBSE) of organic compounds during each tap opening. In order to study the efficiency of ARISTOT, a private network pilot unit has been constructed in our laboratory, equipped with four faucets in parallel, solenoid valves for an automation of the system and a mixing chamber to spike drinking water with odorous compounds in order to have homogenously smelling water at each tap. After enrichment, the stir bars are taken out, in-line thermo-desorbed and analyzed by gas chromatography coupled with a mass spectrometer. The results showed the high sensitivity of ARISTOT, which was able to quickly monitor odorous compounds at the sub ng/L level. A "multishot" method was developed to analyze chemicals concentrated on the seven stir bars in only one chromatographic run, thereby increasing the sensitivity of the system. Higher enrichment factors were obtained under low water flow rates or by using longer stir bars and/or stir bars with a higher PDMS film thickness. No significant loss of extracted compounds was reported for flow rates between 2 and 4L/min. This allowed us to spike the stir bars with an internal standard prior to sampling in order to monitor the analytical variations. It was also observed that hot water increases the loss of enriched solutes but the quantification can be corrected by internal standard addition.

  6. Simultaneous determination and assessment of 4-nonylphenol, bisphenol A and triclosan in tap water, bottled water and baby bottles.

    PubMed

    Li, Xu; Ying, Guang-Guo; Su, Hao-Chang; Yang, Xiao-Bing; Wang, Li

    2010-08-01

    This study investigated the levels of 4-nonylphenol (4-NP), bisphenol A (BPA) and triclosan (TCS) in bottled water and tap water in Guangzhou and release of these chemicals from baby bottles using gas chromatography-mass spectrometry with negative chemical ionization. Results show that 4-NP was present in all the bottled water while 17 out of 21 contained BPA and 18 out of 21 contained TCS. Their concentrations in bottled water ranged from 108 to 298 ng/L, 17.6 to 324 ng/L and 0.6 to 9.7 ng/L, respectively. Five of the tap water samples from six drinking water plants were found to contain 4-NP and BPA both in June and December, while TCS was detected in the same five plants only in June. The highest concentrations in tap water for 4-NP, BPA and TCS were 1987, 317 and 14.5ng/L, respectively. Daily intakes of 4-NP, BPA and TCS of adults by drinking 2L of tap water were estimated to be 1410, 148 and 10 ng/day, respectively. BPA was found to be released within 24h from four brands of baby bottles at room temperature (24 degrees C), 40 degrees C and 100 degrees C. Increased temperature led to higher release of BPA from the baby bottles. Estimated daily intakes of 4-NP, BPA and TCS for infants were 705, 1340 and 5 ng/day, respectively, by drinking 1L of tap water from a baby bottle at 40 degrees C. This study showed that the exposure to the three compounds from drinking water is unlikely to pose a health risk. Copyright 2010 Elsevier Ltd. All rights reserved.

  7. Middle cerebral artery peak systolic velocity to predict fetal hemoglobin levels in twin anemia-polycythemia sequence.

    PubMed

    Slaghekke, F; Pasman, S; Veujoz, M; Middeldorp, J M; Lewi, L; Devlieger, R; Favre, R; Lopriore, E; Oepkes, D

    2015-10-01

    To evaluate the diagnostic accuracy of middle cerebral artery peak systolic velocity (MCA-PSV) Doppler measurements in prediction of hemoglobin levels in twin anemia-polycythemia sequence (TAPS). This study involved a consecutive cohort comprising monochorionic twin pregnancies complicated by TAPS managed at three European fetal medicine centers between 2005 and 2013. The accuracy of MCA-PSV, measured immediately prior to fetal hemoglobin (Hb) measurement by fetal or cord blood sampling, for prediction of anemia and polycythemia was assessed using 2 × 2 tables. A total of 116 measurements (74 recorded in donors and 42 in recipients) from 43 twin pregnancies complicated by TAPS were available for analysis. MCA-PSV multiples of the median (MoM) values correlated well with Hb levels (r = - 0.86; P < 0.001). The sensitivity of MCA-PSV ≥ 1.5 MoM to predict severe anemia (Hb deficit > 5 SD below the mean) in TAPS donors was 94% (95% CI, 85-98%); specificity was 74% (95% CI, 62-83%); positive and negative predictive values were 76% (95% CI, 65-85%) and 94% (95% CI, 83-98%), respectively. The sensitivity of MCA-PSV ≤ 1.0 MoM to predict polycythemia (Hb level > 5 SD above the mean) in TAPS recipients was 97% (95% CI, 87-99%); specificity was 96% (95% CI, 89-99%); positive and negative predictive values were 93% (95% CI, 81-97%) and 99% (95% CI, 93-100%), respectively. MCA-PSV measurement has high diagnostic accuracy for predicting abnormal Hb levels in fetuses with TAPS. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  8. Investigation of formaldehyde pollution of tap water and rain water using a novel visual colorimetry.

    PubMed

    Murai, K; Okano, M; Kuramitz, H; Hata, N; Kawakami, T; Taguchi, S

    2008-01-01

    The pollution of tap water and rain water with formaldehyde in Toyama Pref., Japan was investigated by means of a simple, rapid and cost-effective visual colorimetry developed by us. The levels of formaldehyde in three tap waters from different sources of dams on mountainside and a well-water pumped in urban area in Toyama Pref. were lower than 0.01 mg L(-1) that was the detection limit of the colorimetry. On the other hand, rain waters were seriously polluted with formaldehyde. Rain waters were sampled from three different sites (urban area, top of hill and industrial area) in Toyama Pref. from autumn to winter in 2006. The levels of formaldehyde in the rain waters ranged from 0.07 to 0.30 mg L(-1). The analytical results by the visual colorimetry were in good agreement with those obtained by GC-MS method. It was confirmed that the colorimetry is excellent for practical use for the determination of formaldehyde. It must be concerned about the pollution of rainwater with formaldehyde, when rain water is applied for tap water and miscellaneous purpose. Copyright IWA Publishing 2008.

  9. Experimental Study on Environment Friendly Tap Hole Clay for Blast Furnace

    NASA Astrophysics Data System (ADS)

    Siva kumar, R.; Mohammed, Raffi; Srinivasa Rao, K.

    2018-03-01

    Blast furnace (BF) is the best possible route of iron production available. Blast furnace is a high pressure vessel where iron ore is melted and liquid iron is produced. The liquid iron is tapped through the hole in Blast Furnace called tap hole. The tapped liquid metal flowing through the tap hole is plugged using a clay called tap hole clay. Tap hole clay (THC) is a unshaped refractory used to plug the tap hole. The tap hole clay extruded through the tap hole using a gun. The tap hole clay is designed to expand and plug the tap hole. The tap hole filled with clay is drilled using drill bit and the hole made through the tap hole to tap the liquid metal accumulated inside the furnace. The number of plugging and drilling varies depending on the volume of the furnace. The tap hole clay need to have certain properties to avoid problems during plugging and drilling. In the present paper tap hole clay properties in industrial use was tested and studied. The problems were identified related to tap hole clay manufacturing. Experiments were conducted in lab scale to solve the identified problems. The present composition was modified with experimental results. The properties of the modified tap hole clay were found suitable and useful for blast furnace operation with lab scale experimental results.

  10. Comparison of supervised machine learning algorithms for waterborne pathogen detection using mobile phone fluorescence microscopy

    NASA Astrophysics Data System (ADS)

    Ceylan Koydemir, Hatice; Feng, Steve; Liang, Kyle; Nadkarni, Rohan; Benien, Parul; Ozcan, Aydogan

    2017-06-01

    Giardia lamblia is a waterborne parasite that affects millions of people every year worldwide, causing a diarrheal illness known as giardiasis. Timely detection of the presence of the cysts of this parasite in drinking water is important to prevent the spread of the disease, especially in resource-limited settings. Here we provide extended experimental testing and evaluation of the performance and repeatability of a field-portable and cost-effective microscopy platform for automated detection and counting of Giardia cysts in water samples, including tap water, non-potable water, and pond water. This compact platform is based on our previous work, and is composed of a smartphone-based fluorescence microscope, a disposable sample processing cassette, and a custom-developed smartphone application. Our mobile phone microscope has a large field of view of 0.8 cm2 and weighs only 180 g, excluding the phone. A custom-developed smartphone application provides a user-friendly graphical interface, guiding the users to capture a fluorescence image of the sample filter membrane and analyze it automatically at our servers using an image processing algorithm and training data, consisting of >30,000 images of cysts and >100,000 images of other fluorescent particles that are captured, including, e.g. dust. The total time that it takes from sample preparation to automated cyst counting is less than an hour for each 10 ml of water sample that is tested. We compared the sensitivity and the specificity of our platform using multiple supervised classification models, including support vector machines and nearest neighbors, and demonstrated that a bootstrap aggregating (i.e. bagging) approach using raw image file format provides the best performance for automated detection of Giardia cysts. We evaluated the performance of this machine learning enabled pathogen detection device with water samples taken from different sources (e.g. tap water, non-potable water, pond water) and achieved a limit of detection of 12 cysts per 10 ml, an average cyst capture efficiency of 79%, and an accuracy of 95%. Providing rapid detection and quantification of waterborne pathogens without the need for a microbiology expert, this field-portable imaging and sensing platform running on a smartphone could be very useful for water quality monitoring in resource-limited settings.

  11. Cerebrospinal Fluid Lumbar Tapping Utilization for Suspected Ventriculoperitoneal Shunt Under-Drainage Malfunctions.

    PubMed

    Lee, Jong-Beom; Ahn, Ho-Young; Lee, Hong-Jae; Yang, Ji-Ho; Yi, Jin-Seok; Lee, Il-Woo

    2017-01-01

    The diagnosis of shunt malfunction can be challenging since neuroimaging results are not always correlated with clinical outcomes. The purpose of this study was to evaluate the efficacy of a simple, minimally invasive cerebrospinal fluid (CSF) lumbar tapping test that predicts shunt under-drainage in hydrocephalus patients. We retrospectively reviewed the clinical and radiological features of 48 patients who underwent routine CSF lumbar tapping after ventriculoperitoneal shunt (VPS) operation using a programmable shunting device. We compared shunt valve opening pressure and CSF lumbar tapping pressure to check under-drainage. The mean pressure difference between valve opening pressure and CSF lumbar tapping pressure of all patients were 2.21±24.57 mmH 2 O. The frequency of CSF lumbar tapping was 2.06±1.26 times. Eighty five times lumbar tapping of 41 patients showed that their VPS function was normal which was consistent with clinical improvement and decreased ventricle size on computed tomography scan. The mean pressure difference in these patients was -3.69±19.20 mmH 2 O. The mean frequency of CSF lumbar tapping was 2.07±1.25 times. Fourteen cases of 10 patients revealed suspected VPS malfunction which were consistent with radiological results and clinical symptoms, defined as changes in ventricle size and no clinical improvement. The mean pressure difference was 38.07±23.58 mmH 2 O. The mean frequency of CSF lumbar tapping was 1.44±1.01 times. Pressure difference greater than 35 mmH 2 O was shown in 2.35% of the normal VPS function group (2 of 85) whereas it was shown in 64.29% of the suspected VPS malfunction group (9 of 14). The difference was statistically significant ( p =0.000001). Among 10 patients with under-drainage, 5 patients underwent shunt revision. The causes of the shunt malfunction included 3 cases of proximal occlusion and 2 cases of distal obstruction and valve malfunction. Under-drainage of CSF should be suspected if CSF lumbar tapping pressure is 35 mmH 2 O higher than the valve opening pressure and shunt malfunction evaluation or adjustment of the valve opening pressure should be made.

  12. System for automatically switching transformer coupled lines

    NASA Technical Reports Server (NTRS)

    Dwinell, W. S. (Inventor)

    1979-01-01

    A system is presented for automatically controlling transformer coupled alternating current electric lines. The secondary winding of each transformer is provided with a center tap. A switching circuit is connected to the center taps of a pair of secondary windings and includes a switch controller. An impedance is connected between the center taps of the opposite pair of secondary windings. The switching circuit has continuity when the AC lines are continuous and discontinuity with any disconnect of the AC lines. Normally open switching means are provided in at least one AC line. The switch controller automatically opens the switching means when the AC lines become separated.

  13. Pharmaceuticals in Tap Water: Human Health Risk Assessment and Proposed Monitoring Framework in China

    PubMed Central

    Leung, Ho Wing; Jin, Ling; Wei, Si; Tsui, Mirabelle Mei Po; Zhou, Bingsheng; Jiao, Liping; Cheung, Pak Chuen; Chun, Yiu Kan

    2013-01-01

    Background: Pharmaceuticals are known to contaminate tap water worldwide, but the relevant human health risks have not been assessed in China. Objectives: We monitored 32 pharmaceuticals in Chinese tap water and evaluated the life-long human health risks of exposure in order to provide information for future prioritization and risk management. Methods: We analyzed samples (n = 113) from 13 cities and compared detected concentrations with existing or newly-derived safety levels for assessing risk quotients (RQs) at different life stages, excluding the prenatal stage. Results: We detected 17 pharmaceuticals in 89% of samples, with most detectable concentrations (92%) at < 50 ng/L. Caffeine (median–maximum, nanograms per liter: 24.4–564), metronidazole (1.8–19.3), salicylic acid (16.6–41.2), clofibric acid (1.2–3.3), carbamazepine (1.3–6.7), and dimetridazole (6.9–14.7) were found in ≥ 20% of samples. Cities within the Yangtze River region and Guangzhou were regarded as contamination hot spots because of elevated levels and frequent positive detections. Of the 17 pharmaceuticals detected, 13 showed very low risk levels, but 4 (i.e., dimetridazole, thiamphenicol, sulfamethazine, and clarithromycin) were found to have at least one life-stage RQ ≥ 0.01, especially for the infant and child life stages, and should be considered of high priority for management. We propose an indicator-based monitoring framework for providing information for source identification, water treatment effectiveness, and water safety management in China. Conclusion: Chinese tap water is an additional route of human exposure to pharmaceuticals, particularly for dimetridazole, although the risk to human health is low based on current toxicity data. Pharmaceutical detection and application of the proposed monitoring framework can be used for water source protection and risk management in China and elsewhere. PMID:23665928

  14. Balance outcomes following a tap dance program for a child with congenital myotonic muscular dystrophy.

    PubMed

    Biricocchi, Charlanne; Drake, JaimeLynn; Svien, Lana

    2014-01-01

    This case report describes the effects of a 6-week progressive tap dance program on static and dynamic balance for a child with type 1 congenital myotonic muscular dystrophy (congenital MMD1). A 6-year-old girl with congenital MMD1 participated in a 1-hour progressive tap dance program. Classes were held once a week for 6 consecutive weeks and included 3 children with adaptive needs and 1 peer with typical development. The Bruininks-Oseretsky Test of Motor Proficiency, second edition (BOT-2) balance subsection and the Pediatric Balance Scale were completed at the beginning of the first class and the sixth class. The participant's BOT-2 score improved from 3 to 14. Her Pediatric Balance Scale score did not change. Participation in a progressive tap dance class by a child with congenital MMD1 may facilitate improvements in static and dynamic balance.

  15. Efficient electrochemical remediation of microcystin-LR in tap water using designer TiO2@carbon electrodes

    NASA Astrophysics Data System (ADS)

    Sanz Lobón, Germán; Yepez, Alfonso; Garcia, Luane Ferreira; Morais, Ruiter Lima; Vaz, Boniek Gontijo; Carvalho, Veronica Vale; de Oliveira, Gisele Augusto Rodrigues; Luque, Rafael; Gil, Eric De Souza

    2017-02-01

    Microcystin-leucine arginine (MC-LR) is the most abundant and toxic secondary metabolite produced by freshwater cyanobacteria. This toxin has a high potential hazard health due to potential interactions with liver, kidney and the nervous system. The aim of this work was the design of a simple and environmentally friendly electrochemical system based on highly efficient nanostructured electrodes for the removal of MC-LR in tap water. Titania nanoparticles were deposited on carbon (graphite) under a simple and efficient microwave assisted approach for the design of the electrode, further utilized in the electrochemical remediation assays. Parameters including the applied voltage, time of removal and pH (natural tap water or alkaline condition) were investigated in the process, with results pointing to a high removal efficiency for MC-LR (60% in tap water and 90% in alkaline media experiments, under optimized conditions).

  16. Efficient electrochemical remediation of microcystin-LR in tap water using designer TiO2@carbon electrodes

    PubMed Central

    Sanz Lobón, Germán; Yepez, Alfonso; Garcia, Luane Ferreira; Morais, Ruiter Lima; Vaz, Boniek Gontijo; Carvalho, Veronica Vale; de Oliveira, Gisele Augusto Rodrigues; Luque, Rafael; Gil, Eric de Souza

    2017-01-01

    Microcystin-leucine arginine (MC-LR) is the most abundant and toxic secondary metabolite produced by freshwater cyanobacteria. This toxin has a high potential hazard health due to potential interactions with liver, kidney and the nervous system. The aim of this work was the design of a simple and environmentally friendly electrochemical system based on highly efficient nanostructured electrodes for the removal of MC-LR in tap water. Titania nanoparticles were deposited on carbon (graphite) under a simple and efficient microwave assisted approach for the design of the electrode, further utilized in the electrochemical remediation assays. Parameters including the applied voltage, time of removal and pH (natural tap water or alkaline condition) were investigated in the process, with results pointing to a high removal efficiency for MC-LR (60% in tap water and 90% in alkaline media experiments, under optimized conditions). PMID:28145477

  17. Grade 10 Thai students' scientific argumentation in learning about electric field through science, technology, and society (STS) approach

    NASA Astrophysics Data System (ADS)

    Chitnork, Amporn; Yuenyong, Chokchai

    2018-01-01

    The research aimed to enhance Grade 10 Thai students' scientific argumentation in learning about electric field through science, technology, and society (STS) approach. The participants included 45 Grade 10 students who were studying in a school in Nongsonghong, Khon Kaen, Thailand. Methodology regarded interpretive paradigm. The intervention was the force unit which was provided based on Yuenyong (2006) STS approach. Students learned about the STS electric field unit for 4 weeks. The students' scientific argumentation was interpreted based on Toulmin's argument pattern or TAP. The TAP provided six components of argumentation including data, claim, warrants, qualifiers, rebuttals and backing. Tools of interpretation included students' activity sheets, conversation, journal writing, classroom observation and interview. The findings revealed that students held the different pattern of argumentation. Then, they change pattern of argumentation close to the TAP. It indicates that the intervention of STS electric field unit enhance students to develop scientific argumentation. This finding may has implication of further enhancing scientific argumentation in Thailand.

  18. Comparison of the success rate between self-drilling and self-tapping miniscrews: a systematic review and meta-analysis.

    PubMed

    Yi, Jianru; Ge, Mengke; Li, Meile; Li, Chunjie; Li, Yu; Li, Xiaobing; Zhao, Zhihe

    2017-06-01

    Both the self-drilling and self-tapping miniscrews have been commonly used as anchorage reinforcement devices in orthodontic treatment. The aim of this study was to compare the success rates of self-drilling and self-tapping miniscrews in orthodontic practice. Literature searches were performed by electronic search in database including PubMed, Embase, Cochrane Central Register of Controlled Trials, China National Knowledge Infrastructure and SIGLE, and manual search of relevant journals and reference lists of included studies. Randomized controlled trials, clinical controlled trials and cohort studies comparing the success rates of self-drilling and self-tapping miniscrews as orthodontic anchorage. The data of success rates and root contact rates were extracted by two investigators independently. After evaluating the risk of bias, the odds ratios (ORs) and 95% confidence intervals (CIs) were calculated. Subgroup analysis was performed on the basis of study design, follow-ups, participant ages and immediate/delayed loading. Sensitivity analysis was performed to test the stability of the results in meta-analysis. Six studies assessed as high quality were included in the meta-analysis. The meta-analysis results showed no difference between the two types of screws in the success rates. The root contact rates of the two screws were similar, while self-drilling miniscrews displayed higher risk of failure when contacting with a tooth root. Currently available clinical evidence suggests that the success rates of self-tapping and self-drilling miniscrews are similar. Determination of the position and direction of placement should be more precise when self-drilling miniscrews are used in sites with narrow root proximity. None. None. © The Author 2016. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com

  19. [Legionella spp. contamination in indoor air: preliminary results of an Italian multicenter study].

    PubMed

    Montagna, Maria Teresa; De Giglio, Osvalda; Napoli, Christian; Cannova, Lucia; Cristina, Maria Luisa; Deriu, Maria Grazia; Delia, Santi Antonino; Giuliano, Ada; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Mura, Ida; Pennino, Francesca; Rossini, Angelo; Tardivo, Stefano; Torre, Ida; Torregrossa, Maria Valeria; Villafrate, Maria Rosaria; Albertini, Roberto; Pasquarella, Cesira

    2014-01-01

    To propose a standardized protocol for the evaluation of Legionella contamination in air. A bathroom having a Legionella contamination in water >1,000 cfu/l was selected in 10 different healthcare facilities. Air contamination was assessed by active (Surface Air System, SAS) and passive (Index of Microbial Air, IMA) sampling for 8 hours, about 1 m away from the floor and 50 cm from the tap water. Two hundred liters of air were sampled by SAS every 12 min, after flushing water for 2 min. The IMA value was calculated as the mean value of colony forming units/16 plates exposed during sampling (2 plates/hour). Water contamination was evaluated at T0, after 4 and 8 hours, according to the standard methods. Air contamination by Legionella was found in three healthcare facilities (one with active and two with passive sampling), showing a concomitant tap water contamination (median=40,000; range 1,100-43,000 cfu/l). The remaining seven hospitals isolated Legionella spp. exclusively from water samples (median=8,000; range 1,200-70,000 cfu/l). Our data suggest that environmental Legionella contamination cannot be assessed only through the air sampling, even in the presence of an important water contamination.

  20. Tapping a Potential for the Good of All.

    ERIC Educational Resources Information Center

    Rabo, Annika

    Historically, the spread of universal formal mass education in the West is closely linked to emergence of nation-states. This is also true of the Third World. The salient feature of education today is that it reflects a model of society in which citizens, including children, are seen as a potential to be tapped for development of the nation, as…

  1. Lumbar Puncture (Spinal Tap) (For Parents)

    MedlinePlus

    ... specific bacteria growing in the sample, a bacterial culture is sent to the lab and these results ... treatment while waiting for the results of the culture. Risks A lumbar puncture is considered a safe ...

  2. All Tapped Out: Touchscreen Interactivity and Young Children’s Word Learning

    PubMed Central

    Russo-Johnson, Colleen; Troseth, Georgene; Duncan, Charlotte; Mesghina, Almaz

    2017-01-01

    Touchscreen devices differ from passive screen media in promoting physical interaction with events on the screen. Two studies examined how young children’s screen-directed actions related to self-regulation (Study 1) and word learning (Study 2). In Study 1, 30 2-year-old children’s tapping behaviors during game play were related to their self-regulation, measured using Carlson’s snack task: girls and children with high self-regulation tapped significantly less during instruction portions of an app (including object labeling events) than did boys and children with low self-regulation. Older preschoolers (N = 47, aged 4–6 years) tapped significantly less during instruction than 2-year-olds did. Study 2 explored whether the particular way in which 170 children (2–4 years of age) interacted with a touchscreen app affected their learning of novel object labels. Conditions in which children tapped or dragged a named object to move it across the screen required different amounts of effort and focus, compared to a non-interactive (watching) condition. Age by sex interactions revealed a particular benefit of dragging (a motorically challenging behavior) for preschool girls’ learning compared to that of boys, especially for girls older than age 2. Boys benefited more from watching than dragging. Children from low socioeconomic status families learned more object names when dragging objects versus tapping them, possibly because tapping is a prepotent response that does not require thoughtful attention. Parents and industry experts should consider age, sex, self-regulation, and the physical requirements of children’s engagement with touchscreens when designing and using educational content. PMID:28446895

  3. Four quadrant transversus abdominis plane block and continuous transversus abdominis plane analgesia: a 3-year prospective audit in 124 patients.

    PubMed

    Niraj, G; Kelkar, Aditi; Hart, Elaine; Kaushik, Vipul; Fleet, Danny; Jameson, John

    2015-11-01

    Transversus abdominis plane (TAP) blocks have been reported to be an effective method of providing analgesia after abdominal surgery. To perform a prospective audit on the effectiveness of a novel technique of providing continuous transversus abdominis plane (TAP) analgesia in patients undergoing emergency and elective abdominal surgery. Prospective single center audit over a 3-year period. University hospital. One hundred twenty-four American Society of Anesthesiologists I to IV adult patients presenting for elective as well as emergency abdominal surgery in whom epidural analgesia was contraindicated or refused. Four quadrant TAP blocks and continuous TAP analgesia. Numerical rating scale pain scores at rest and on coughing, nausea scores, satisfaction scores, complications, frequency of analgesia failure, therapeutic failure with continuous TAP analgesia and opioid consumption. One hundred twenty-four patients who received continuous TAP analgesia were audited. This included 34 patients for elective open surgery, 36 patients for emergency laparotomy, and 54 patients who underwent elective laparoscopic colorectal surgery. Surgical incision was within the dermatomal limit of the block in 70% of the patients (88/124). Therapeutic failure with the technique was 10%. Frequency of analgesic failure over the 48-hour period was none in 39% and below 5 episodes in 57%. Four quadrant transversus abdominis plane blocks and continuous TAP analgesia is an effective technique for providing postoperative analgesia after abdominal surgery. It has the potential to be used as a sole analgesic technique when the surgical incision is within its dermatomal limit. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Survey of fluoride levels in vended water stations.

    PubMed

    Jadav, Urvi G; Archarya, Bhavini S; Velasquez, Gisela M; Vance, Bradley J; Tate, Robert H; Quock, Ryan L

    2014-01-01

    This study sought to measure the fluoride concentration of water derived from vended water stations (VWS) and to identify its clinical implications, especially with regard to caries prevention and fluorosis. VWS and corresponding tap water samples were collected from 34 unique postal zip codes; samples were analyzed in duplicate for fluoride concentration. Average fluoride concentration in VWS water was significantly lower than that of tap water (P < 0.001). Fluoride concentration in the VWS water ranged from <0.01 ppm to 0.04 ppm, with a mean concentration of 0.02 ppm (±0.02 ppm). Patients utilizing VWS as their primary source of drinking water may not be receiving optimal caries preventive benefits; thus dietary fluoride supplementation may be indicated. Conversely, to minimize the risk of fluorosis in infants consuming reconstituted infant formula, water from a VWS may be used.

  5. Assessment of Drinking Water Quality from Bottled Water Coolers

    PubMed Central

    FARHADKHANI, Marzieh; NIKAEEN, Mahnaz; AKBARI ADERGANI, Behrouz; HATAMZADEH, Maryam; NABAVI, Bibi Fatemeh; HASSANZADEH, Akbar

    2014-01-01

    Abstract Background Drinking water quality can be deteriorated by microbial and toxic chemicals during transport, storage and handling before using by the consumer. This study was conducted to evaluate the microbial and physicochemical quality of drinking water from bottled water coolers. Methods A total of 64 water samples, over a 5-month period in 2012-2013, were collected from free standing bottled water coolers and water taps in Isfahan. Water samples were analyzed for heterotrophic plate count (HPC), temperature, pH, residual chlorine, turbidity, electrical conductivity (EC) and total organic carbon (TOC). Identification of predominant bacteria was also performed by sequence analysis of 16S rDNA. Results The mean HPC of water coolers was determined at 38864 CFU/ml which exceeded the acceptable level for drinking water in 62% of analyzed samples. The HPC from the water coolers was also found to be significantly (P < 0.05) higher than that of the tap waters. The statistical analysis showed no significant difference between the values of pH, EC, turbidity and TOC in water coolers and tap waters. According to sequence analysis eleven species of bacteria were identified. Conclusion A high HPC is indicative of microbial water quality deterioration in water coolers. The presence of some opportunistic pathogens in water coolers, furthermore, is a concern from a public health point of view. The results highlight the importance of a periodic disinfection procedure and monitoring system for water coolers in order to keep the level of microbial contamination under control. PMID:26060769

  6. Transversus abdominis plane block using a short-acting local anesthetic for postoperative pain after laparoscopic colorectal surgery: a systematic review and meta-analysis.

    PubMed

    Oh, Tak Kyu; Lee, Se-Jun; Do, Sang-Hwan; Song, In-Ae

    2018-02-01

    Transversus abdominis plane (TAP) block using a short-acting local anesthetic as part of multimodal analgesia is efficient in various abdominal surgeries, including laparoscopic surgery. However, information regarding its use in laparoscopic colorectal surgery is still limited and sometimes controversial. Therefore, we conducted a systematic review and meta-analysis to determine whether TAP block using a short-acting anesthetic has a positive postoperative analgesic outcome in patients who have undergone laparoscopic colorectal surgery. We searched for studies comparing the postoperative pain outcome after laparoscopic colorectal surgery between patients who received TAP block and a control group (placebo or no treatment). Outcome measures were early pain at rest (numeric rating scale [NRS] score at 0-2 h postoperatively), late pain at movement (NRS score at 24 h postoperatively), late pain at rest (NRS score at 24 h postoperatively), and postoperative opioid consumption (up to 24 h postoperatively). We used a random-effects model for the meta-analysis and Egger's regression test to detect publication bias. We included six studies involving 452 patients (224 in the TAP block group, 228 in the control group). Early and late pain scores at movement were significantly different between the TAP block and control groups (standardized mean difference: - 0.695, P < 0.0001 for early pain and - 0.242, P = 0.029 for late pain). There was no significant difference between the TAP block and control groups in early pain at rest (P = 0.475), late pain at rest (P = 0.826), and postoperative opioid consumption (P = 0.257). The TAP block using a short-acting anesthetic had a significant effect on the postoperative pain outcome in the early (0-2 h) and late (24 h) period at movement. However, it did not have a significant effect on the postoperative pain outcome in the early (0-2 h) and late (24 h) periods at rest after laparoscopic surgery.

  7. Modeling best practices in chronic disease management: the Arthritis Program at Southlake Regional Health Centre.

    PubMed

    Bain, Lorna; Mierdel, Sandra; Thorne, Carter

    2012-01-01

    Researchers, hospital administrators and governments are striving to define competencies in interprofessional care and education, as well as to identify effective models in chronic disease management. For more than 25 years The Arthritis Program (TAP) at Southlake Regional Health Centre in Newmarket, Ontario, has actively practiced within these two interrelated priorities, which are now at the top of the healthcare agenda in Ontario and Canada. The approximately 135 different rheumatic conditions are the primary cause of long-term disability in Canada, affecting those from youth to the senior years, with an economic burden estimated at $4.4 billion (CAD$) annually, and growing. For the benefit of healthcare managers and their clients with chronic conditions, this article discusses TAP's history and demonstrable success, predicated on an educational model of patient self-management and self-efficacy. Also outlined are TAP's contributions in supporting evidence-based best practices in interprofessional collaboration and chronic disease management; approaches that are arguably understudied and under-practiced. Next steps for TAP include a larger role in empirical research in chronic-disease management and integration of a formal training program to benefit health professionals launching or expanding their interprofessional programs using TAP as the dynamic clinical example.

  8. The influence of TAP1 and TAP2 gene polymorphisms on TAP function and its inhibition by viral immune evasion proteins.

    PubMed

    Praest, P; Luteijn, R D; Brak-Boer, I G J; Lanfermeijer, J; Hoelen, H; Ijgosse, L; Costa, A I; Gorham, R D; Lebbink, R J; Wiertz, E J H J

    2018-06-04

    Herpesviruses encode numerous immune evasion molecules that interfere with the immune system, particularly with certain stages in the MHC class I antigen presentation pathway. In this pathway, the transporter associated with antigen processing (TAP) is a frequent target of viral immune evasion strategies. This ER-resident transporter is composed of the proteins TAP1 and TAP2, and plays a crucial role in the loading of viral peptides onto MHC class I molecules. Several variants of TAP1 and TAP2 occur in the human population, some of which are linked to autoimmune disorders and susceptibility to infections. Here, we assessed the influence of naturally occurring TAP variants on peptide transport and MHC class I expression. In addition, we tested the inhibitory capacity of three viral immune evasion proteins, the TAP inhibitors US6 from human cytomegalovirus, ICP47 from herpes simplex virus type 1 and BNLF2a from Epstein-Barr virus, for a series of TAP1 and TAP2 variants. Our results suggest that these TAP polymorphisms have no or limited effect on peptide transport or MHC class I expression. Furthermore, our study indicates that the herpesvirus-encoded TAP inhibitors target a broad spectrum of TAP variants; inhibition of TAP is not affected by the naturally occurring polymorphisms of TAP tested in this study. Our findings suggest that the long-term coevolution of herpesviruses and their host did not result in selection of inhibitor-resistant TAP variants in the human population. Copyright © 2018. Published by Elsevier Ltd.

  9. Eliciting Cervical Vestibular-Evoked Myogenic Potentials by Bone-Conducted Vibration via Various Tapping Sites.

    PubMed

    Tseng, Chia-Chen; Young, Yi-Ho

    2016-01-01

    This study compared bone-conducted vibration (BCV) cervical vestibular-evoked myogenic potentials (cVEMPs) via tapping at various skull sites in healthy subjects and patients with vestibular migraine (VM) to optimize stimulation conditions. Twenty healthy subjects underwent a series of cVEMP tests by BCV tapping via a minishaker at the Fz (forehead), Cz (vertex), and inion (occiput) sites in a randomized order of tapping sites. Another 20 VM patients were also enrolled in this study for comparison. All 20 healthy subjects had clear BCV cVEMPs when tapping at the inion (100%) or Cz (100%), but not at the Fz (75%). Mean p13 and n23 latencies from the Cz tapping were significantly longer than those from the Fz tapping, but not longer than those from the inion tapping. Unlike healthy subjects, tapping at the Cz (95%) elicited a significantly higher response rate of present cVEMPs than tapping at the inion (78%) in 20 VM patients (40 ears), because seven of nine VM ears with absent cVEMPs by inion tapping turned out to be present cVEMPs by Cz tapping. While both inion and Cz tapping elicited 100% response rate of cVEMPs for healthy individuals, Cz tapping had a higher response rate of cVEMPs than inion tapping for the VM group. In cases of total loss of saccular function, cVEMPs could not be activated by either inion or Cz tapping. However, if residual saccular function remains, Cz tapping may activate saccular afferents more efficiently than inion tapping.

  10. The First Association of a Primary Amebic Meningoencephalitis Death with Culturable Naegleria fowleri in Tap Water from a U.S. Treated Public Drinking Water System

    PubMed Central

    Cope, Jennifer R.; Ratard, Raoult C.; Hill, Vincent R.; Sokol, Theresa; Causey, Jonathan Jake; Yoder, Jonathan S.; Mirani, Gayatri; Mull, Bonnie; Mukerjee, Kimberly A.; Narayanan, Jothikumar; Doucet, Meggie; Qvarnstrom, Yvonne; Poole, Charla N.; Akingbola, Olugbenga A.; Ritter, Jana; Xiong, Zhenggang; da Silva, Alexandre; Roellig, Dawn; Van Dyke, Russell; Stern, Harlan; Xiao, Lihua; Beach, Michael J.

    2015-01-01

    Background Naegleria fowleri is a climate-sensitive, thermophilic ameba found in warm, freshwater lakes and rivers. Primary amebic meningoencephalitis (PAM), which is almost universally fatal, occurs when N. fowleri–containing water enters the nose, typically during swimming, and N. fowleri migrates to the brain via the olfactory nerve. In August 2013, a 4-year-old child died of meningoencephalitis of unknown etiology in a Louisiana hospital. Methods Clinical and environmental testing and a case investigation were initiated to determine the cause of death and to identify potential exposures. Results Based on testing of CSF and brain specimens, the child was diagnosed with PAM. His only reported water exposure was tap water; in particular, tap water that was used to supply water to a lawn water slide on which the child had played extensively prior to becoming ill. Water samples were collected from both the home and the water distribution system that supplied the home and tested; N. fowleri were identified in water samples from both the home and the water distribution system. Conclusions This case is the first reported PAM death associated with culturable N. fowleri in tap water from a U.S. treated drinking water system. This case occurred in the context of an expanding geographic range for PAM beyond southern tier states with recent case reports from Minnesota, Kansas, and Indiana. This case also highlights the role of adequate disinfection throughout drinking water distribution systems and the importance of maintaining vigilance when operating drinking water systems using source waters with elevated temperatures. PMID:25595746

  11. The first association of a primary amebic meningoencephalitis death with culturable Naegleria fowleri in tap water from a US treated public drinking water system.

    PubMed

    Cope, Jennifer R; Ratard, Raoult C; Hill, Vincent R; Sokol, Theresa; Causey, Jonathan Jake; Yoder, Jonathan S; Mirani, Gayatri; Mull, Bonnie; Mukerjee, Kimberly A; Narayanan, Jothikumar; Doucet, Meggie; Qvarnstrom, Yvonne; Poole, Charla N; Akingbola, Olugbenga A; Ritter, Jana M; Xiong, Zhenggang; da Silva, Alexandre J; Roellig, Dawn; Van Dyke, Russell B; Stern, Harlan; Xiao, Lihua; Beach, Michael J

    2015-04-15

    Naegleria fowleri is a climate-sensitive, thermophilic ameba found in warm, freshwater lakes and rivers. Primary amebic meningoencephalitis (PAM), which is almost universally fatal, occurs when N. fowleri-containing water enters the nose, typically during swimming, and migrates to the brain via the olfactory nerve. In August 2013, a 4-year-old boy died of meningoencephalitis of unknown etiology in a Louisiana hospital. Clinical and environmental testing and a case investigation were initiated to determine the cause of death and to identify potential exposures. Based on testing of cerebrospinal fluid and brain specimens, the child was diagnosed with PAM. His only reported water exposure was tap water; in particular, tap water that was used to supply water to a lawn water slide on which the child had played extensively prior to becoming ill. Water samples were collected from both the home and the water distribution system that supplied the home and tested; N. fowleri was identified in water samples from both the home and the water distribution system. This case is the first reported PAM death associated with culturable N. fowleri in tap water from a US treated drinking water system. This case occurred in the context of an expanding geographic range for PAM beyond southern states, with recent case reports from Minnesota, Kansas, and Indiana. This case also highlights the role of adequate disinfection throughout drinking water distribution systems and the importance of maintaining vigilance when operating drinking water systems using source waters with elevated temperatures. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  12. PeakForce Tapping resolves individual microvilli on living cells.

    PubMed

    Schillers, Hermann; Medalsy, Izhar; Hu, Shuiqing; Slade, Andrea L; Shaw, James E

    2016-02-01

    Microvilli are a common structure found on epithelial cells that increase the apical surface thus enhancing the transmembrane transport capacity and also serve as one of the cell's mechanosensors. These structures are composed of microfilaments and cytoplasm, covered by plasma membrane. Epithelial cell function is usually coupled to the density of microvilli and its individual size illustrated by diseases, in which microvilli degradation causes malabsorption and diarrhea. Atomic force microscopy (AFM) has been widely used to study the topography and morphology of living cells. Visualizing soft and flexible structures such as microvilli on the apical surface of a live cell has been very challenging because the native microvilli structures are displaced and deformed by the interaction with the probe. PeakForce Tapping® is an AFM imaging mode, which allows reducing tip-sample interactions in time (microseconds) and controlling force in the low pico-Newton range. Data acquisition of this mode was optimized by using a newly developed PeakForce QNM-Live Cell probe, having a short cantilever with a 17-µm-long tip that minimizes hydrodynamic effects between the cantilever and the sample surface. In this paper, we have demonstrated for the first time the visualization of the microvilli on living kidney cells with AFM using PeakForce Tapping. The structures observed display a force dependence representing either the whole microvilli or just the tips of the microvilli layer. Together, PeakForce Tapping allows force control in the low pico-Newton range and enables the visualization of very soft and flexible structures on living cells under physiological conditions. © 2015 The Authors Journal of Molecular Recognition Published by John Wiley & Sons Ltd.

  13. Determination of (4-methylcyclohexyl)methanol isomers by heated purge-and-trap GC/MS in water samples from the 2014 Elk River, West Virginia, chemical spill

    USGS Publications Warehouse

    Foreman, William T.; Rose, Donna L.; Chambers, Douglas B.; Crain, Angela S.; Murtagh, Lucinda K.; Thakellapalli, Haresh; Wang, Kung K.

    2015-01-01

    A heated purge-and-trap gas chromatography/mass spectrometry method was used to determine the cis- and trans-isomers of (4-methylcyclohexyl)methanol (4-MCHM), the reported major component of the Crude MCHM/Dowanol™ PPh glycol ether material spilled into the Elk River upriver from Charleston, West Virginia, on January 9, 2014. The trans-isomer eluted first and method detection limits were 0.16-μg L−1trans-, 0.28-μg L−1cis-, and 0.4-μg L−1 Total (total response of isomers) 4-MCHM. Estimated concentrations in the spill source material were 491-g L−1trans- and 277-g L−1cis-4-MCHM, the sum constituting 84% of the source material assuming its density equaled 4-MCHM. Elk River samples collected ⩽ 3.2 km downriver from the spill on January 15 had low (⩽2.9 μg L−1 Total) 4-MCHM concentrations, whereas the isomers were not detected in samples collected 2 d earlier at the same sites. Similar 4-MCHM concentrations (range 4.2–5.5 μg L−1 Total) occurred for samples of the Ohio River at Louisville, Kentucky, on January 17, ∼630 km downriver from the spill. Total 4-MCHM concentrations in Charleston, WV, office tap water decreased from 129 μg L−1 on January 27 to 2.2 μg L−1on February 3, but remained detectable in tap samples through final collection on February 25 indicating some persistence of 4-MCHM within the water distribution system. One isomer of methyl 4-methylcyclohexanecarboxylate was detected in all Ohio River and tap water samples, and both isomers were detected in the source material spilled.

  14. An improved push-pull voltage fed converter using a tapped output-filter inductor

    NASA Technical Reports Server (NTRS)

    Wester, G. W.

    1983-01-01

    A new concept of using a tapped output-filter inductor and an auxiliary commutating diode to reduce the likelihood of transformer core saturation in a push-pull, voltage-fed converter is presented. The linearized circuit model and transfer functions are derived with a hybrid approach using both state-space and circuit averaging. Operation of the new converter - including parasitic effects - is discussed, and a design equation for inductor tap ratio is established. It is predicted and experimentally confirmed that the new converter has more symmetrical transformer core operation, and the potential exits for lower transistor turnon current and reduced transistor voltage stress. These benefits reduce switching loss and enhance transistor reliability.

  15. Fluoride exposure and indicators of thyroid functioning in the Canadian population: implications for community water fluoridation

    PubMed Central

    Barberio, Amanda M; Hosein, F Shaun; Quiñonez, Carlos; McLaren, Lindsay

    2017-01-01

    Background There are concerns that altered thyroid functioning could be the result of ingesting too much fluoride. Community water fluoridation (CWF) is an important source of fluoride exposure. Our objectives were to examine the association between fluoride exposure and (1) diagnosis of a thyroid condition and (2) indicators of thyroid functioning among a national population-based sample of Canadians. Methods We analysed data from Cycles 2 and 3 of the Canadian Health Measures Survey (CHMS). Logistic regression was used to assess associations between fluoride from urine and tap water samples and the diagnosis of a thyroid condition. Multinomial logistic regression was used to examine the relationship between fluoride exposure and thyroid-stimulating hormone (TSH) level (low/normal/high). Other available variables permitted additional exploratory analyses among the subset of participants for whom we could discern some fluoride exposure from drinking water and/or dental products. Results There was no evidence of a relationship between fluoride exposure (from urine and tap water) and the diagnosis of a thyroid condition. There was no statistically significant association between fluoride exposure and abnormal (low or high) TSH levels relative to normal TSH levels. Rerunning the models with the sample constrained to the subset of participants for whom we could discern some source(s) of fluoride exposure from drinking water and/or dental products revealed no significant associations. Conclusion These analyses suggest that, at the population level, fluoride exposure is not associated with impaired thyroid functioning in a time and place where multiple sources of fluoride exposure, including CWF, exist. PMID:28839078

  16. Transporters associated with antigen processing (TAP) in sea bass (Dicentrarchus labrax, L.): molecular cloning and characterization of TAP1 and TAP2.

    PubMed

    Pinto, Rute D; Pereira, Pedro J B; dos Santos, Nuno M S

    2011-11-01

    The transporters associated with antigen processing (TAP), play an important role in the MHC class I antigen presentation pathway. In this work, sea bass (Dicentrarchus labrax) TAP1 and TAP2 genes and transcripts were isolated and characterized. Only the TAP2 gene is structurally similar to its human orthologue. As other TAP molecules, sea bass TAP1 and TAP2 are formed by one N-terminal accessory domain, one core membrane-spanning domain and one canonical C-terminal nucleotide-binding domain. Homology modelling of the sea bass TAP dimer predicts that its quaternary structure is in accordance with that of other ABC transporters. Phylogenetic analysis segregates sea bass TAP1 and TAP2 into each subfamily cluster of transporters, placing them in the fish class and suggesting that the basic structure of these transport-associated proteins is evolutionarily conserved. Furthermore, the present data provides information that will enable more studies on the class I antigen presentation pathway in this important fish species. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Effects of aging on control of timing and force of finger tapping.

    PubMed

    Sasaki, Hirokazu; Masumoto, Junya; Inui, Nobuyuki

    2011-04-01

    The present study examined whether the elderly produced a hastened or delayed tap with a negative or positive constant intertap interval error more frequently in self-paced tapping than in the stimulus-synchronized tapping for the 2 N target force at 2 or 4 Hz frequency. The analysis showed that, at both frequencies, the percentage of the delayed tap was larger in the self-paced tapping than in the stimulus-synchronized tapping, whereas the hastened tap showed the opposite result. At the 4 Hz frequency, all age groups had more variable intertap intervals during the self-paced tapping than during the stimulus-synchronized tapping, and the variability of the intertap intervals increased with age. Thus, although the increase in the frequency of delayed taps and variable intertap intervals in the self-paced tapping perhaps resulted from a dysfunction of movement timing in the basal ganglia with age, the decline in timing accuracy was somewhat improved by an auditory cue. The force variability of tapping at 4 Hz further increased with age, indicating an effect of aging on the control of force.

  18. A comparitive clinical study between self tapping and drill free screws as a source of rigid orthodontic anchorage.

    PubMed

    Gupta, Nishant; Kotrashetti, S M; Naik, Vijay

    2012-03-01

    Self-tapping miniscrews are commonly being used as a temporary anchorage device for orthodontic purpose. A prerequisite for the insertion of these screws is the preparation of a pilot hole, which is time consuming and may result in damage to nerves, tooth root, drill bit breakage and thermal necrosis of bone. On the other hand the design of drill-free screws enables them to be inserted without drilling. The aim of this prospective study was to compare the stability and clinical response of the soft tissue around the self tapping and drill free screws when used for orthodontic anchorage for en mass retraction of maxillary anterior teeth. The study sample consisted of 20 patients requiring retraction of maxillary anterior teeth. The screws were placed in the alveolar bone between maxillary 2nd premolar and 1st molar bilaterally at the junction of attached gingiva and moveable mucosa. Pilot hole was drilled on the side which was selected for insertion of the self tapping screw under copious irrigation, after which it was inserted. Drill free screw was inserted on the contralateral side without predrilling. All screws were immediately loaded with 150-200 gm of retraction force. Patients were recalled for regular follow up for a period of 6 months. If the screws became mobile or showed any signs of inflammation during the course of the study, they were considered to be a failure. After a period of 6 months an overall success rate of 77.5% was noted. Four self tapping and five drill-free screws failed during the study. There was no statistically significant difference between the two types of screws with respect to success/failure. Mobility was found to be the major cause for the failure. Both self-tapping and the drill-free screws are effective anchorage units. But the latter have an edge over the conventional self-tapping screws because of decrease in operative time, little bone debris, less thermal damage, lower morbidity, and minimal patient discomfort as predrilling is not required, thus they can be used as a viable alternative. But self-tapping screws are still recommended for areas with high bone density and thick cortical bone.

  19. Abdominal tap

    MedlinePlus

    Peritoneal tap; Paracentesis; Ascites - abdominal tap; Cirrhosis - abdominal tap; Malignant ascites - abdominal tap ... abdominal cavity ( most often cancer of the ovaries ) Cirrhosis of the liver Damaged bowel Heart disease Infection ...

  20. An estimation of finger-tapping rates and load capacities and the effects of various factors.

    PubMed

    Ekşioğlu, Mahmut; İşeri, Ali

    2015-06-01

    The aim of this study was to estimate the finger-tapping rates and finger load capacities of eight fingers (excluding thumbs) for a healthy adult population and investigate the effects of various factors on tapping rate. Finger-tapping rate, the total number of finger taps per unit of time, can be used as a design parameter of various products and also as a psychomotor test for evaluating patients with neurologic problems. A 1-min tapping task was performed by 148 participants with maximum volitional tempo for each of eight fingers. For each of the tapping tasks, the participant with the corresponding finger tapped the associated key in the standard position on the home row of a conventional keyboard for touch typing. The index and middle fingers were the fastest fingers for both hands, and little fingers the slowest. All dominant-hand fingers, except little finger, had higher tapping rates than the fastest finger of the nondominant hand. Tapping rate decreased with age and smokers tapped faster than nonsmokers. Tapping duration and exercise had also significant effect on tapping rate. Normative data of tapping rates and load capacities of eight fingers were estimated for the adult population. In designs of psychomotor tests that require the use of tapping rate or finger load capacity data, the effects of finger, age, smoking, and tapping duration need to be taken into account. The findings can be used for ergonomic designs requiring finger-tapping capacity and also as a reference in psychomotor tests. © 2015, Human Factors and Ergonomics Society.

  1. Spontaneous eye blinks are entrained by finger tapping.

    PubMed

    Cong, D-K; Sharikadze, M; Staude, G; Deubel, H; Wolf, W

    2010-02-01

    We studied the mutual cross-talk between spontaneous eye blinks and continuous, self-paced unimanual and bimanual tapping. Both types of motor activities were analyzed with regard to their time-structure in synchronization-continuation tapping tasks which involved different task instructions, namely "standard" finger tapping (Experiment 1), "strong" tapping (Experiment 2) requiring more forceful finger movements, and "impulse-like" tapping (Experiment 3) where upward-downward finger movements had to be very fast. In a further control condition (Experiment 4), tapping was omitted altogether. The results revealed a prominent entrainment of spontaneous blink behavior by the manual tapping, with bimanual tapping being more effective than unimanual tapping, and with the "strong" and "impulse-like" tapping showing the largest effects on blink timing. Conversely, we found no significant effects of the tapping on the timing of the eye blinks across all experiments. The findings suggest a functional overlap of the motor control structures responsible for voluntary, rhythmic finger movements and eye blinking behavior.

  2. A case-control study on association of proteasome subunit beta 8 (PSMB8) and transporter associated with antigen processing 1 (TAP1) polymorphisms and their transcript levels in vitiligo from Gujarat.

    PubMed

    Jadeja, Shahnawaz D; Mansuri, Mohmmad Shoab; Singh, Mala; Dwivedi, Mitesh; Laddha, Naresh C; Begum, Rasheedunnisa

    2017-01-01

    Autoimmunity has been implicated in the destruction of melanocytes from vitiligo skin. Major histocompatibility complex (MHC) class-II linked genes proteasome subunit beta 8 (PSMB8) and transporter associated with antigen processing 1 (TAP1), involved in antigen processing and presentation have been reported to be associated with several autoimmune diseases including vitiligo. To explore PSMB8 rs2071464 and TAP1 rs1135216 single nucleotide polymorphisms and to estimate the expression of PSMB8 and TAP1 in patients with vitiligo and unaffected controls from Gujarat. PSMB8 rs2071464 polymorphism was genotyped using polymerase chain reaction- restriction fragment length polymorphism (PCR-RFLP) and TAP1 rs1135216 polymorphism was genotyped by amplification refractory mutation system-polymerase chain reaction (ARMS-PCR) in 378 patients with vitiligo and 509 controls. Transcript levels of PSMB8 and TAP1 were measured in the PBMCs of 91 patients and 96 controls by using qPCR. Protein levels of PSMB8 were also determined by Western blot analysis. The frequency of 'TT' genotype of PSMB8 polymorphism was significantly lowered in patients with generalized and active vitiligo (p = 0.019 and p = 0.005) as compared to controls suggesting its association with the activity of the disease. However, TAP1 polymorphism was not associated with vitiligo susceptibility. A significant decrease in expression of PSMB8 at both transcript level (p = 0.002) as well as protein level (p = 0.0460) was observed in vitiligo patients as compared to controls. No significant difference was observed between patients and controls for TAP1 transcripts (p = 0.553). Interestingly, individuals with the susceptible CC genotype of PSMB8 polymorphism showed significantly reduced PSMB8 transcript level as compared to that of CT and TT genotypes (p = 0.009 and p = 0.003 respectively). PSMB8 rs2071464 was associated with generalized and active vitiligo from Gujarat whereas TAP1 rs1135216 showed no association. The down-regulation of PSMB8 in patients with risk genotype 'CC' advocates the vital role of PSMB8 in the autoimmune basis of vitiligo.

  3. Targeting Behavioral Symptoms and Functional Decline in Dementia: A Randomized Clinical Trial.

    PubMed

    Gitlin, Laura N; Arthur, Paul; Piersol, Catherine; Hessels, Virginia; Wu, Samuel S; Dai, Yunfeng; Mann, William C

    2018-02-01

    Dementia-related behavioral symptoms and functional dependence result in poor quality of life for persons with dementia and their caregivers. The goal was to determine whether a home-based activity program (Tailored Activity Program; TAP-VA) would reduce behavioral symptoms and functional dependence of veterans with dementia and caregiver burden. Single-blind (interviewer), parallel, randomized, controlled trial (Clinicaltrials.gov: NCT01357564). Veteran's homes. Veterans with dementia and their family caregivers (N = 160 dyads). Dyads in TAP-VA underwent 8 sessions with occupational therapists to customize activities to the interests and abilities of the veterans and educate their caregivers about dementia and use of customized activity. Caregivers assigned to attention control received up to 8 telephone-based dementia education sessions with a research team member. Primary outcomes included number of behaviors and frequency of their occurrence multiplied by severity of occurrence; secondary outcomes were functional dependence, pain, emotional well-being, caregiver burden (time spent caregiving, upset with behaviors) and affect at 4 (primary endpoint) and 8 months. Of 160 dyads (n = 76 TAP-VA; n = 84 control), 111 completed 4-month interviews (n = 51 TAP-VA; n = 60 control), and 103 completed 8-month interviews (n = 50 TAP-VA; n = 53 control). At 4 months, compared to controls, the TAP-VA group showed reductions in number (difference in mean change from baseline = -0.68, 95% CI = -1.23 to -0.13) and frequency by severity (-24.3, 95% CI = -45.6 to -3.1) of behavioral symptoms, number of activities needing assistance with (-0.80, 95% CI = -1.41 to -0.20), functional dependence level (4.09, 95% CI = 1.06, 7.13), and pain (-1.18, 95% CI = -2.10 to -0.26). Caregivers of veterans in TAP-VA reported less behavior-related distress. Benefits did not extend to 8 months. TAP-VA had positive immediate effects and no adverse events. Because TAP-VA reduces behavioral symptoms, slows functional dependence, and alleviates pain and caregiver distress, it is a viable treatment option for families. © 2017, Copyright the Authors Journal compilation © 2017, The American Geriatrics Society.

  4. Cerebrospinal Fluid Lumbar Tapping Utilization for Suspected Ventriculoperitoneal Shunt Under-Drainage Malfunctions

    PubMed Central

    Lee, Jong-Beom; Ahn, Ho-Young; Lee, Hong-Jae; Yang, Ji-Ho; Yi, Jin-Seok; Lee, Il-Woo

    2017-01-01

    Objective The diagnosis of shunt malfunction can be challenging since neuroimaging results are not always correlated with clinical outcomes. The purpose of this study was to evaluate the efficacy of a simple, minimally invasive cerebrospinal fluid (CSF) lumbar tapping test that predicts shunt under-drainage in hydrocephalus patients. Methods We retrospectively reviewed the clinical and radiological features of 48 patients who underwent routine CSF lumbar tapping after ventriculoperitoneal shunt (VPS) operation using a programmable shunting device. We compared shunt valve opening pressure and CSF lumbar tapping pressure to check under-drainage. Results The mean pressure difference between valve opening pressure and CSF lumbar tapping pressure of all patients were 2.21±24.57 mmH2O. The frequency of CSF lumbar tapping was 2.06±1.26 times. Eighty five times lumbar tapping of 41 patients showed that their VPS function was normal which was consistent with clinical improvement and decreased ventricle size on computed tomography scan. The mean pressure difference in these patients was −3.69±19.20 mmH2O. The mean frequency of CSF lumbar tapping was 2.07±1.25 times. Fourteen cases of 10 patients revealed suspected VPS malfunction which were consistent with radiological results and clinical symptoms, defined as changes in ventricle size and no clinical improvement. The mean pressure difference was 38.07±23.58 mmH2O. The mean frequency of CSF lumbar tapping was 1.44±1.01 times. Pressure difference greater than 35 mmH2O was shown in 2.35% of the normal VPS function group (2 of 85) whereas it was shown in 64.29% of the suspected VPS malfunction group (9 of 14). The difference was statistically significant (p=0.000001). Among 10 patients with under-drainage, 5 patients underwent shunt revision. The causes of the shunt malfunction included 3 cases of proximal occlusion and 2 cases of distal obstruction and valve malfunction. Conclusion Under-drainage of CSF should be suspected if CSF lumbar tapping pressure is 35 mmH2O higher than the valve opening pressure and shunt malfunction evaluation or adjustment of the valve opening pressure should be made. PMID:28061484

  5. Viral Inhibition of the Transporter Associated with Antigen Processing (TAP): A Striking Example of Functional Convergent Evolution

    PubMed Central

    Verweij, Marieke C.; Horst, Daniëlle; Griffin, Bryan D.; Luteijn, Rutger D.; Davison, Andrew J.; Ressing, Maaike E.; Wiertz, Emmanuel J. H. J.

    2015-01-01

    Herpesviruses are large DNA viruses that are highly abundant within their host populations. Even in the presence of a healthy immune system, these viruses manage to cause lifelong infections. This persistence is partially mediated by the virus entering latency, a phase of infection characterized by limited viral protein expression. Moreover, herpesviruses have devoted a significant part of their coding capacity to immune evasion strategies. It is believed that the close coexistence of herpesviruses and their hosts has resulted in the evolution of viral proteins that specifically attack multiple arms of the host immune system. Cytotoxic T lymphocytes (CTLs) play an important role in antiviral immunity. CTLs recognize their target through viral peptides presented in the context of MHC molecules at the cell surface. Every herpesvirus studied to date encodes multiple immune evasion molecules that effectively interfere with specific steps of the MHC class I antigen presentation pathway. The transporter associated with antigen processing (TAP) plays a key role in the loading of viral peptides onto MHC class I molecules. This is reflected by the numerous ways herpesviruses have developed to block TAP function. In this review, we describe the characteristics and mechanisms of action of all known virus-encoded TAP inhibitors. Orthologs of these proteins encoded by related viruses are identified, and the conservation of TAP inhibition is discussed. A phylogenetic analysis of members of the family Herpesviridae is included to study the origin of these molecules. In addition, we discuss the characteristics of the first TAP inhibitor identified outside the herpesvirus family, namely, in cowpox virus. The strategies of TAP inhibition employed by viruses are very distinct and are likely to have been acquired independently during evolution. These findings and the recent discovery of a non-herpesvirus TAP inhibitor represent a striking example of functional convergent evolution. PMID:25880312

  6. Social marketing as a means of raising community awareness of an HIV voluntary counselling and testing site in Soweto, South Africa.

    PubMed

    Hewer, Raymond; Motaung, Enea; Mathope, Alicia; Meyer, Debra

    2005-05-01

    In order for HIV voluntary counselling and testing (VCT) to be successful, the approval of and attendance at the VCT centre by the community it serves is necessary. To this end, the Township AIDS Project (TAP), which has VCT sites serving the greater Soweto area, attempts to maintain a high degree of visibility in the community through campaigning and various forms of advertising. To determine whether the social marketing strategies employed by the organisation encouraged attendance, pre-test questionnaires completed by volunteers attending the TAP VCT site located in the Meadowlands district of Soweto were retrospectively analysed. During 2003, approximately 34% of volunteers were made aware of the VCT site through marketing. However, a more important factor in volunteer awareness was word of mouth, with about 46% of volunteers informed of TAP VCT by a friend, partner or relative. This attests to the success of the marketing strategies employed by the TAP organisation in raising community awareness and attendance at the VCT site investigated in this study. In total, 1 141 volunteers completed a questionnaire and 1 054 of these consented to being tested for HIV antibodies. The level of infection among the sample of individuals tested at this clinic-based VCT programme was 29.9%.

  7. Lithium levels in tap water and psychotic experiences in a general population of adolescents.

    PubMed

    Shimodera, Shinji; Koike, Shinsuke; Ando, Shuntaro; Yamasaki, Syudo; Fujito, Ryosuke; Endo, Kaori; Iijima, Yudai; Yamamoto, Yu; Morita, Masaya; Sawada, Ken; Ohara, Nobuki; Okazaki, Yuji; Nishida, Atsushi

    2018-06-09

    Recently, several epidemiologic studies have reported that lithium in drinking water may be associated with lower rates of suicide mortality, lower incidence of dementia, and lower levels of adolescents' depression and aggression at the population level. However, to our knowledge, no study has investigated lithium level in tap water in relation to psychotic experiences in a general population of adolescents. This is the first study to investigate this using a large dataset. Information on psychotic experiences, distress associated with these experiences, and depressive symptoms were collected in 24 public junior high schools in Kochi Prefecture in Japan. Samples were collected from sources that supplied drinking water to schools, and lithium levels were measured using atomic absorption spectrophotometry. The association of lithium levels with psychotic experiences, considering distress as a degree of severity, was examined using an ordinal logistic regression model with schools and depressive symptoms as random effects. In total, 3040 students responded to the self-reporting questionnaire (response rate: 91.8%). Lithium levels in tap water were inversely associated with psychotic experiences (p = 0.021). We concluded that lithium level in tap water was inversely associated with psychotic experiences among a general population of adolescents and may have a preventive effect for such experiences and distress. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Extraction of fast neuronal changes from multichannel functional near-infrared spectroscopy signals using independent component analysis

    NASA Astrophysics Data System (ADS)

    Morren, Geert; Wolf, Martin; Lemmerling, Philippe; Wolf, Ursula; Choi, Jee H.; Gratton, Enrico; De Lathauwer, Lieven; Van Huffel, Sabine

    2002-06-01

    Fast changes in the range of milliseconds in the optical properties of cerebral tissue, which are associated with brain activity, can be detected using non-invasive near-infrared spectroscopy (NIRS). These changes in light scattering are due to an alteration in the refractive index at neuronal membranes. The aim of this study was to develop highly sensitive data analysis algorithms to detect this fast signal, which is small compared to other physiological signals. A frequency-domain tissue oximeter, whose laser diodes were modulated at 110MHz was used. The amplitude, mean intensity and phase of the modulated optical signal was measured at 96Hz sample rate. The probe consisting of 4 crossed source detector pairs was placed above the motor cortex, contralateral to the hand performing a tapping exercise consisting of alternating rest- and tapping periods of 20s each. The tapping frequency, which was set to 3.55Hz or 2.5 times the heart rate of the subject to avoid the influence of harmonics on the signal, could not be observed in any of the individual signals measured by the detectors. An adaptive filter was used to remove the arterial pulsatility from the optical signals. Independent Component Analysis allowed to separate signal components in which the tapping frequency was clearly visible.

  9. Persistence of antibiotic resistance genes and bacterial community changes in drinking water treatment system: From drinking water source to tap water.

    PubMed

    Su, Hao-Chang; Liu, You-Sheng; Pan, Chang-Gui; Chen, Jun; He, Liang-Ying; Ying, Guang-Guo

    2018-03-01

    As emerging contaminants, antibiotic resistance genes (ARGs) have become a public concern. This study aimed to investigate the occurrence and diversity of ARGs, and variation in the composition of bacterial communities in source water, drinking water treatment plants, and tap water in the Pearl River Delta region, South China. Various ARGs were present in the different types of water. Among the 27 target ARGs, floR and sul1 dominated in source water from three large rivers in the region. Pearson correlation analysis suggested that sul1, sul2, floR, and cmlA could be potential indicators for ARGs in water samples. The total abundance of the detected ARGs in tap water was much lower than that in source water. Sand filtration and sedimentation in drinking water treatment plants could effectively remove ARGs; in contrast, granular activated carbon filtration increased the abundance of ARGs. It was found that Pseudomonas may be involved in the proliferation and dissemination of ARGs in the studied drinking water treatment system. Bacteria and ARGs were still present in tap water after treatment, though they were significantly reduced. More research is needed to optimize the water treatment process for ARG removal. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. High-dose versus low-dose local anaesthetic for transversus abdominis plane block post-Caesarean delivery analgesia: a meta-analysis.

    PubMed

    Ng, S C; Habib, A S; Sodha, S; Carvalho, B; Sultan, P

    2018-02-01

    The optimal local-anaesthetic (LA) dose for transversus-abdominis-plane (TAP) block is unclear. In this meta-analysis, we aimed to determine whether TAP blocks for Caesarean delivery (CD) with low-dose (LD) LA demonstrated non-inferiority in terms of analgesic efficacy, compared with high-dose (HD) LA. A literature search was performed for randomised controlled trials examining the analgesic efficacy of TAP blocks vs control after CD. The different dosing used in these studies was classified as HD or LD (bupivacaine equivalents >50 or ≤50 mg per block side, respectively). The pooled results of each dose group vs control were indirectly compared using the Q test. The primary outcome was 24 h opioid consumption. Secondary outcomes included 6 and 24 h postoperative pain scores, time to first analgesia, 6 h opioid consumption, opioid-related side-effects, and maternal satisfaction. Fourteen studies consisting of 770 women (389 TAP and 381 control) were included. Compared with controls, the 24 h opioid consumption (milligram morphine equivalents) was lower in HD [mean difference (MD) 95% confidence interval (CI) -22.41 (-38.56, -6.26); P=0.007; I 2 =93%] and LD [MD 95% CI -16.29 (-29.74, -2.84); P=0.02; I 2 =98%] TAP groups. However, no differences were demonstrated between the HD and LD groups (P=0.57). There were also no differences between the HD and LD groups for the 6 h opioid consumption, time to first analgesia, 6 and 24 h pain scores, postoperative nausea and vomiting, pruritus, and maternal satisfaction. Low-dose TAP blocks for Caesarean delivery provide analgesia and opioid-sparing effects comparable with the high-dose blocks. This suggests that lower doses can be used to reduce local anaesthetic toxicity risk without compromising the analgesic efficacy. Copyright © 2017 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  11. Drinking water consumption patterns among adults-SMS as a novel tool for collection of repeated self-reported water consumption.

    PubMed

    Säve-Söderbergh, Melle; Toljander, Jonas; Mattisson, Irene; Åkesson, Agneta; Simonsson, Magnus

    2018-03-01

    Studies have shown that the average drinking water consumption ranges between 0.075 and 3 L/day for adults with both national and regional differences. For exposure assessment of drinking water hazards, country-specific drinking water consumption data including sources of the consumed water may therefore be warranted. To estimate the amount and source of drinking water consumed among adults in Sweden, we collected self-reported estimates using both traditional methods (telephone interviews, web questionnaire) and a novel method (Short Message Service, SMS questionnaires) in a population from an average sized Swedish municipality. Monthly SMS questionnaires were sent out during one year to obtain longitudinal information as well. SMS showed to be a promising tool for collecting self-reported consumption, as most citizens could participate and the method showed high response rate. Data collected via the SMS questionnaire shows an average consumption of cold tap water of 4.9 glasses/24 h (one glass=200 ml), while the average estimates of cold tap water collected by the traditional methods range from 4.5 to 7.0 glasses/24 h. For statistical distributions, the mean daily consumption of cold tap water for the population was best fitted to a gamma distribution. About 70% of the cold tap water is consumed at home. Based on the results from the SMS study, we suggest using 1 l/day for the average adult population and 2.5 l/day for high consumers for risk assessment of cold tap water consumption. As 46% of the tap water consumed is heated, we suggest using 1.85 l/day for total tap water consumption.

  12. Drinking water consumption patterns among adults—SMS as a novel tool for collection of repeated self-reported water consumption

    PubMed Central

    Säve-Söderbergh, Melle; Toljander, Jonas; Mattisson, Irene; Åkesson, Agneta; Simonsson, Magnus

    2018-01-01

    Studies have shown that the average drinking water consumption ranges between 0.075 and 3 L/day for adults with both national and regional differences. For exposure assessment of drinking water hazards, country-specific drinking water consumption data including sources of the consumed water may therefore be warranted. To estimate the amount and source of drinking water consumed among adults in Sweden, we collected self-reported estimates using both traditional methods (telephone interviews, web questionnaire) and a novel method (Short Message Service, SMS questionnaires) in a population from an average sized Swedish municipality. Monthly SMS questionnaires were sent out during one year to obtain longitudinal information as well. SMS showed to be a promising tool for collecting self-reported consumption, as most citizens could participate and the method showed high response rate. Data collected via the SMS questionnaire shows an average consumption of cold tap water of 4.9 glasses/24 h (one glass=200 ml), while the average estimates of cold tap water collected by the traditional methods range from 4.5 to 7.0 glasses/24 h. For statistical distributions, the mean daily consumption of cold tap water for the population was best fitted to a gamma distribution. About 70% of the cold tap water is consumed at home. Based on the results from the SMS study, we suggest using 1 l/day for the average adult population and 2.5 l/day for high consumers for risk assessment of cold tap water consumption. As 46% of the tap water consumed is heated, we suggest using 1.85 l/day for total tap water consumption. PMID:28612838

  13. Contributing effect of various washing procedures and additives on the decline pattern of diethofencarb in crown daisy, a model of leafy vegetables.

    PubMed

    Kim, Sung-Woo; Abd El-Aty, A M; Choi, Jeong-Heui; Lee, Young-Jun; Lieu, Truong T B; Chung, Hyung Suk; Rahman, Md Musfiqur; Choi, Ok-Ja; Shin, Ho-Chul; Rhee, Gyu-Seek; Chang, Moon-Ik; Kim, Hee Jung; Shim, Jae-Han

    2016-06-15

    The effects of various washing procedures, including stagnant, running, and stagnant and running tap water, and the use of washing solutions and additives, namely NaCl (1% and 2%), vinegar (2%, 5%, and 10%), detergent (0.5% and 1%), and charcoal (1% and 2%), on the reduction rate of diethofencarb were estimated in field-incurred crown daisy, a model of leafy vegetables, grown under greenhouses located in 3 different areas (Gwangju, Naju, and Muan). The original Quick, Easy, Cheap, Effective, Rugged, and Safe "QuEChERS" method was modified for extraction and liquid chromatography-tandem mass spectrometry (LC/MS/MS) was used for analysis. The recovery of diethofencarb in unwashed and washed samples was satisfactory and ranged between 84.28% and 115.32% with relative standard deviations (RSDs) of <6%. The residual levels decreased following washing with stagnant, running, and stagnant+running tap water (i.e., decline in levels increased from 65.08% to 85.02%, 69.99 to 86.79, and 74.75 to 88.96, respectively). The percentage of decline increased and ranged from 77.46% to 91.19% following washing with various solutions. Application of 1% detergent was found to be the most effective washing method for reducing the residues in crown daisy. Additionally, washing with stagnant and running tap water or even stagnant water for 5 min might reduce the residue levels substantially, making the prepared food safe for human consumption. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Children's drinking water: parental preferences and implications for fluoride exposure.

    PubMed

    Sriraman, Natasha K; Patrick, Patricia A; Hutton, Kara; Edwards, Karen S

    2009-01-01

    The purposes of this study were to: describe children's drinking water sources; determine if any demographic factors are associated with water choice; describe parents' reasons for selecting bottled water; and determine parents' ability to provide enough information about their drinking water for providers to assess children's fluoride exposure. Subjects were parents of children 6 months to 15-years-old. A questionnaire was verbally administered in English or Spanish. Chi-square analyses were used to evaluate associations among study variables. Of 194 parents, 134 (69%) gave their children bottled water either exclusively or with tap water. Bottled water use was not significantly associated with the primary source of tap water, parent's education level, or household income. Reasons for giving children bottled water included: fear of contaminants in tap water; taste and/or smell of tap water; and convenience of bottled water. For parents using bottled water, over 65% did not know the brand's fluoride content. Barriers to an accurate fluoride assessment include frequent bottled water use and parental uncertainty about its fluoride content. By initiating communication with parents and educating them about fluoride sources, health care and dental providers may be able to better evaluate the adequacy of children's fluoride exposure and decide whether fluoride supplementation is necessary.

  15. Developmental Trajectory of Motor Deficits in Preschool Children with ADHD.

    PubMed

    Sweeney, Kristie L; Ryan, Matthew; Schneider, Heather; Ferenc, Lisa; Denckla, Martha Bridge; Mahone, E Mark

    2018-01-01

    Motor deficits persisting into childhood (>7 years) are associated with increased executive and cognitive dysfunction, likely due to parallel neural circuitry. This study assessed the longitudinal trajectory of motor deficits in preschool children with ADHD, compared to typically developing (TD) children, in order to identify individuals at risk for anomalous neurological development. Participants included 47 children (21 ADHD, 26 TD) ages 4-7 years who participated in three visits (V1, V2, V3), each one year apart (V1=48-71 months, V2=60-83 months, V3=72-95 months). Motor variables assessed included speed (finger tapping and sequencing), total overflow, and axial movements from the Revised Physical and Neurological Examination for Subtle Signs (PANESS). Effects for group, visit, and group-by-visit interaction were examined. There were significant effects for group (favoring TD) for finger tapping speed and total axial movements, visit (performance improving with age for all 4 variables), and a significant group-by-visit interaction for finger tapping speed. Motor speed (repetitive finger tapping) and quality of axial movements are sensitive markers of anomalous motor development associated with ADHD in children as young as 4 years. Conversely, motor overflow and finger sequencing speed may be less sensitive in preschool, due to ongoing wide variations in attainment of these milestones.

  16. Associations between respiratory sinus arrhythmia (RSA) reactivity and effortful control in preschool-age children.

    PubMed

    Sulik, Michael J; Eisenberg, Nancy; Spinrad, Tracy L; Silva, Kassondra M

    2015-07-01

    We tested whether respiratory sinus arrhythmia (RSA) reactivity in response to each of three self-regulation tasks (bird and dragon; knock-tap; and gift wrap) would predict self-regulation performance in a sample of 101 preschool-age children (M age = 4.49, SD = .64). While controlling for baseline RSA, decreases in RSA from bird and dragon to knock-tap (but not from baseline to bird and dragon) predicted a latent variable measuring self-regulation. Furthermore, increases in RSA from the knock-tap to gift wrap-the only task involving delay of gratification-were related to concurrent task performance while controlling for the relation between RSA reactivity and the latent self-regulation variable. Results suggest that the relations between RSA reactivity and self-regulatory ability are influenced by task-specific demands and possibly by task order. Furthermore, RSA reactivity appears to relate differently to performance on motivationally salient self-regulation tasks such as delay of gratification relative to cool executive function tasks. © 2015 Wiley Periodicals, Inc.

  17. An Evaluation of Microbial and Chemical Contamination Sources Related to the Deterioration of Tap Water Quality in the Household Water Supply System

    PubMed Central

    Lee, Yoonjin

    2013-01-01

    The predominant microorganisms in samples taken from shower heads in residences in the Korean city “N” were Stenotrophomonas maltophilia, Sphingomonas paucimobilis, Acidovorax temperans, and Microbacterium lacticum. Legionella was not detected in this case. The volatile organic compounds (VOCs) vinylacetate, NN-DMA, cis-1,2-dichloroethylene, epichlorohydrin, and styrene were measured in five types of plastic pipes: PVC, PB, PP, PE, and cPVC. The rate of multiplication of the heterotrophic plate count (HPC) attached on the copper pipe in contact with hot tap water was higher than the rate for the copper pipe in contact with cold tap water. Biofilm accumulation on stainless steel pipes with added acetate (3 mg/L) was 2.56 times higher than the non-supplemented condition. Therefore, the growth of HPC in the pipe system was affected by the type and availability of nutrients and depended on variables such as heating during the hot water supply. PMID:24018837

  18. An evaluation of microbial and chemical contamination sources related to the deterioration of tap water quality in the household water supply system.

    PubMed

    Lee, Yoonjin

    2013-09-06

    The predominant microorganisms in samples taken from shower heads in residences in the Korean city "N" were Stenotrophomonas maltophilia, Sphingomonas paucimobilis, Acidovorax temperans, and Microbacterium lacticum. Legionella was not detected in this case. The volatile organic compounds (VOCs) vinylacetate, NN-DMA, cis-1,2-dichloroethylene, epichlorohydrin, and styrene were measured in five types of plastic pipes: PVC, PB, PP, PE, and cPVC. The rate of multiplication of the heterotrophic plate count (HPC) attached on the copper pipe in contact with hot tap water was higher than the rate for the copper pipe in contact with cold tap water. Biofilm accumulation on stainless steel pipes with added acetate (3 mg/L) was 2.56 times higher than the non-supplemented condition. Therefore, the growth of HPC in the pipe system was affected by the type and availability of nutrients and depended on variables such as heating during the hot water supply.

  19. Data eye monitor method and apparatus

    DOEpatents

    Gara, Alan G [Mount Kisco, NY; Marcella, James A [Rochester, MN; Ohmacht, Martin [Yorktown Heights, NY

    2012-01-31

    An apparatus and method for providing a data eye monitor. The data eye monitor apparatus utilizes an inverter/latch string circuit and a set of latches to save the data eye for providing an infinite persistent data eye. In operation, incoming read data signals are adjusted in the first stage individually and latched to provide the read data to the requesting unit. The data is also simultaneously fed into a balanced XOR tree to combine the transitions of all incoming read data signals into a single signal. This signal is passed along a delay chain and tapped at constant intervals. The tap points are fed into latches, capturing the transitions at a delay element interval resolution. Using XORs, differences between adjacent taps and therefore transitions are detected. The eye is defined by segments that show no transitions over a series of samples. The eye size and position can be used to readjust the delay of incoming signals and/or to control environment parameters like voltage, clock speed and temperature.

  20. BIOMECHANICAL EVALUATION OF THE INFLUENCE OF CERVICAL SCREWS TAPPING AND DESIGN.

    PubMed

    Silva, Patricia; Rosa, Rodrigo César; Shimano, Antonio Carlos; Albuquerque de Paula, Francisco José; Volpon, José Batista; Aparecido Defino, Helton Luiz

    2009-01-01

    To assess if the screw design (self-drilling/self-tapping) and the pilot hole tapping could affect the insertion torque and screw pullout strength of the screw used in anterior fixation of the cervical spine. Forty self-tapping screws and 20 self-drilling screws were inserted into 10 models of artificial bone and 10 cervical vertebrae of sheep. The studied parameters were the insertion torque and pullout strength. The following groups were created: Group I-self-tapping screw insertion after pilot hole drilling and tapping; Group II-self-tapping screw insertion after pilot hole drilling without tapping; Group III-self-drilling screw insertion without drilling and tapping. In Groups I and II, the pilot hole had 14.0 mm in depth and was made with a 3mmn drill, while tapping was made with a 4mm tap. The insertion torque was measured and the pullout test was performed. The comparison between groups was made considering the mean insertion torque and the maximum mean pullout strength with the variance analysis (ANOVA; p≤ 0.05). Previous drilling and tapping of pilot hole significantly decreased the insertion torque and the pullout strength. The insertion torque and pullout strength of self-drilling screws were significantly higher when compared to self-tapping screws inserted after pilot hole tapping.

  1. Chromatographic background drift correction coupled with parallel factor analysis to resolve coelution problems in three-dimensional chromatographic data: quantification of eleven antibiotics in tap water samples by high-performance liquid chromatography coupled with a diode array detector.

    PubMed

    Yu, Yong-Jie; Wu, Hai-Long; Fu, Hai-Yan; Zhao, Juan; Li, Yuan-Na; Li, Shu-Fang; Kang, Chao; Yu, Ru-Qin

    2013-08-09

    Chromatographic background drift correction has been an important field of research in chromatographic analysis. In the present work, orthogonal spectral space projection for background drift correction of three-dimensional chromatographic data was described in detail and combined with parallel factor analysis (PARAFAC) to resolve overlapped chromatographic peaks and obtain the second-order advantage. This strategy was verified by simulated chromatographic data and afforded significant improvement in quantitative results. Finally, this strategy was successfully utilized to quantify eleven antibiotics in tap water samples. Compared with the traditional methodology of introducing excessive factors for the PARAFAC model to eliminate the effect of background drift, clear improvement in the quantitative performance of PARAFAC was observed after background drift correction by orthogonal spectral space projection. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Trace-metal leaching from plumbing materials exposed to acidic ground water in three areas of the coastal plain of New Jersey

    USGS Publications Warehouse

    Kish, G.R.; Macy, J.A.; Mueller, R.T.

    1987-01-01

    The U.S. Geological Survey analyzed trace metal concentrations in tap water from domestic wells in newly constructed homes in Berkeley Township, Ocean County and Galloway Township, Atlantic County, N. J. The potable water distribution systems in all of the homes sampled are constructed primarily of copper with lead-based solder points. Home water treatment is used in Berkeley Township but not in Galloway Township. Tap water was collected after the water had been standing in the pipes overnight. In Berkeley, 6 to 11 samples exceeded both the U.S. Environmental Protection Agency 's primary drinking water regulation (DWR) for lead (50 microgram/L) and the secondary drinking water regulation (SDWR) for copper (1,000 microgram/L). In Galloway, 12 of 14 samples exceeded the DWR for lead and 13 of 14 exceeded the SDWR for copper. After collecting the standing-water samples, the water was left running for 15 minutes and a second sample was collected. None of the running-water samples exceeded the regulations for lead or copper. Available data suggest a correlation between the residence time of soft, acidic groundwater in new home plumbing systems and elevated trace-metal concentrations in drinking water derived from domestic wells within the New Jersey Coastal Plain. (USGS)

  3. A Cross-Sectional Study of Tobacco Advertising, Promotion, and Sponsorship in Airports across Europe and the United States

    PubMed Central

    Soong, Andrea; Navas-Acien, Ana; Pang, Yuanjie; Lopez, Maria Jose; Garcia-Esquinas, Esther; Stillman, Frances A.

    2016-01-01

    Tobacco advertising, promotion, and sponsorship (TAPS) bans are effective and are increasingly being implemented in a number of venues and countries, yet the state of TAPS in airports and their effect on airport smoking behavior is unknown. The objective of this study was to evaluate the presence of TAPS in airports across Europe and the US, and to begin to examine the relationship between TAPS and smoking behaviors in airports. We used a cross-sectional study design to observe 21 airports in Europe (11) and the US (10). Data collectors observed points of sale for tobacco products, types of products sold, advertisements and promotions, and branding or logos that appeared in the airport. Tobacco products were sold in 95% of all airports, with significantly more sales in Europe than the US. Advertisements appeared mostly in post-security areas; however, airports with advertisements in pre-security areas had significantly more smokers observed outdoors than airports without advertisements in pre-security areas. Tobacco branding appeared in designated smoking rooms as well as on non-tobacco products in duty free shops. TAPS are widespread in airports in Europe and the US and might be associated with outdoor smoking, though further research is needed to better understand any relationship between the two. This study adds to a growing body of research on tobacco control in air transit and related issues. As smoke-free policies advance, they should include comprehensive TAPS bans that extend to airport facilities. PMID:27690072

  4. A Cross-Sectional Study of Tobacco Advertising, Promotion, and Sponsorship in Airports across Europe and the United States.

    PubMed

    Soong, Andrea; Navas-Acien, Ana; Pang, Yuanjie; Lopez, Maria Jose; Garcia-Esquinas, Esther; Stillman, Frances A

    2016-09-28

    Tobacco advertising, promotion, and sponsorship (TAPS) bans are effective and are increasingly being implemented in a number of venues and countries, yet the state of TAPS in airports and their effect on airport smoking behavior is unknown. The objective of this study was to evaluate the presence of TAPS in airports across Europe and the US, and to begin to examine the relationship between TAPS and smoking behaviors in airports. We used a cross-sectional study design to observe 21 airports in Europe (11) and the US (10). Data collectors observed points of sale for tobacco products, types of products sold, advertisements and promotions, and branding or logos that appeared in the airport. Tobacco products were sold in 95% of all airports, with significantly more sales in Europe than the US. Advertisements appeared mostly in post-security areas; however, airports with advertisements in pre-security areas had significantly more smokers observed outdoors than airports without advertisements in pre-security areas. Tobacco branding appeared in designated smoking rooms as well as on non-tobacco products in duty free shops. TAPS are widespread in airports in Europe and the US and might be associated with outdoor smoking, though further research is needed to better understand any relationship between the two. This study adds to a growing body of research on tobacco control in air transit and related issues. As smoke-free policies advance, they should include comprehensive TAPS bans that extend to airport facilities.

  5. Modulated microwave microscopy and probes used therewith

    DOEpatents

    Lai, Keji; Kelly, Michael; Shen, Zhi-Xun

    2012-09-11

    A microwave microscope including a probe tip electrode vertically positionable over a sample and projecting downwardly from the end of a cantilever. A transmission line connecting the tip electrode to the electronic control system extends along the cantilever and is separated from a ground plane at the bottom of the cantilever by a dielectric layer. The probe tip may be vertically tapped near or at the sample surface at a low frequency and the microwave signal reflected from the tip/sample interaction is demodulated at the low frequency. Alternatively, a low-frequency electrical signal is also a non-linear electrical element associated with the probe tip to non-linearly interact with the applied microwave signal and the reflected non-linear microwave signal is detected at the low frequency. The non-linear element may be semiconductor junction formed near the apex of the probe tip or be an FET formed at the base of a semiconducting tip.

  6. Production of aluminum-silicon alloy and ferrosilicon and commercial purity aluminum by the direct reduction process. Third interim technical report, Phase C for the period 1980 July 1-1980 September 30

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bruno, M.J.

    1980-10-01

    Pilot reactor VSR-3 operation in the third quarter was directed to tapping molten alloy product. Modifications to the hearth region included a tapping furnace to maintain taphole temperature, a graphite ring filter to separate carbides from matal and an alumina liner to eliminate carbiding from reaction of alloy with the graphite hearth walls. Tapping was not successful, however, due to high alloy viscosity from a large concentration of carbides. Three runs were made on the pilot crystallizer to determine the effects of alloy composition, cooling rate, tamping rate, remelt temperature and rate on eutectic Al-Si yield.

  7. Rapid detection of total and viable Legionella pneumophila in tap water by immunomagnetic separation, double fluorescent staining and flow cytometry.

    PubMed

    Keserue, Hans-Anton; Baumgartner, Andreas; Felleisen, Richard; Egli, Thomas

    2012-11-01

    We developed a rapid detection method for Legionella pneumophila (Lp) by filtration, immunomagnetic separation, double fluorescent staining, and flow cytometry (IMS-FCM method). The method requires 120 min and can discriminate 'viable' and 'membrane-damaged' cells. The recovery is over 85% of spiked Lp SG 1 cells in 1 l of tap water and detection limits are around 50 and 15 cells per litre for total and viable Lp, respectively. The method was compared using water samples from house installations in a blind study with three environmental laboratories performing the ISO 11731 plating method. In 53% of the water samples from different taps and showers significantly higher concentrations of Lp were detected by flow cytometry. No correlation to the plate culture method was found. Since also 'viable but not culturable' (VNBC) cells are detected by our method, this result was expected. The IMS-FCM method is limited by the specificity of the used antibodies; in the presented case they target Lp serogroups 1-12. This and the fact that no Lp-containing amoebae are detected may explain why in 21% of all samples higher counts were observed using the plate culture method. Though the IMS-FCM method is not yet fit to completely displace the established plating method (ISO 11731) for routine Lp monitoring, it has major advantages to plating and can quickly provide important insights into the ecology of this pathogen in water distribution systems. © 2012 The Authors. Microbial Biotechnology © 2012 Society for Applied Microbiology and Blackwell Publishing Ltd.

  8. Occurrences of nitrosamines in chlorinated and chloraminated drinking water in three representative cities, China.

    PubMed

    Luo, Qian; Wang, Donghong; Wang, Zijian

    2012-10-15

    An investigation of the occurrence of nine nitrosamines in drinking water following different water treatment processes was conducted using samples from seven drinking water treatment plants in three cities and tap waters in one city in China. The total nitrosamine levels ranged from not detected (n.d.) to 43.45 ng/L. The species and concentrations of the nine nitrosamines varied with disinfection methods and source waters. N-nitrosodimethylamine (NDMA), which is the nitrosamines of greatest concern, was identified in raw water, disinfecting water, finished water and tap water samples, ranging from 0.8 to 21.6, 0.12 to 24.2, n.d. to 8.8, and n.d. to 13.3 ng/L, respectively. Chloramination alone produced the most significant amounts of NDMA, while ozonation followed by chloramination led to moderately reduced levels. Additionally, chlorination produced relatively less NDMA, while low pressure ultraviolet radiation followed by chlorination could also significantly reduce them. Total organic carbon is one of the most important factors influencing nitrosamines formation in disinfecting water. In contrast, the addition of chlorine following any other disinfection was found to increase the formation of the other eight species of nitrosamines. The three nitrosamines recommended for monitoring by the US EPA were detected in the tap water samples, but most were present at levels below those that pose a risk to human health. Nevertheless, the occurrence and concentration of nitrosamines regulated in the Drinking Water Contaminant Candidate List could cause some potential human effects and therefore warrant attention. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. MSATT Workshop on Innovative Instrumentation for the In Situ Study of Atmosphere-Surface Interactions on Mars

    NASA Technical Reports Server (NTRS)

    Fegley, Bruce, Jr. (Editor); Waenke, Heinrich (Editor)

    1992-01-01

    Papers accepted for the Mars Surface and Atmosphere Through Time (MSATT) Workshop on Innovative Instruments for the In Situ Study of Atmosphere-Surface Interaction of Mars, 8-9 Oct. 1992 in Mainz, Germany are included. Topics covered include: a backscatter Moessbauer spectrometer (BaMS) for use on Mars; database of proposed payloads and instruments for SEI missions; determination of martian soil mineralogy and water content using the Thermal Analyzer for Planetary Soils (TAPS); in situ identification of the martian surface material and its interaction with the martian atmosphere using DTA/GC; mass spectrometer-pyrolysis experiment for atmospheric and soil sample analysis on the surface of Mars; and optical luminescence spectroscopy as a probe of the surface mineralogy of Mars.

  10. Evaluation of triple antibiotic paste removal by different irrigation procedures.

    PubMed

    Berkhoff, Julie A; Chen, Paul B; Teixeira, Fabricio B; Diogenes, Anibal

    2014-08-01

    Regenerative endodontics aims to re-establish a functional pulp-dentin complex. First, the root canal system is disinfected primarily by irrigants and medicaments. Triple antibiotic paste (TAP), a commonly used intracanal medicament, has been shown to be directly toxic to stem cells at concentrations greater than 0.1 g/mL. Thus, its complete removal is a crucial step in regenerative endodontic procedures. We hypothesized that currently used irrigation techniques do not completely remove TAP from root canal system. TAP was radiolabeled by the incorporation of I(125), and calcium hydroxide (Ultracal; Ultradent, South Jordan, UT) was radiolabeled with Ca(45). The intracanal medicaments were placed into standardized human root segments and incubated for 28 days at 37°C. Then, canals were irrigated with EndoActivator (Dentsply, Tulsa, OK), passive ultrasonic irrigation, EndoVac (SybronEndo, Coppell, TX), or a syringe/Max-i-Probe needle (Dentsply Rinn, Elgin, IL) using a standardized irrigation protocol in a closed system. Radioactivity levels (counts per minute values) were measured for each tooth before and after the irrigation protocols. Furthermore, the canals were sequentially enlarged and dentin samples collected and evaluated for radioactivity. Data were analyzed with analysis of variance and Bonferroni post hoc testing (P < .05). Approximately 88% of the TAP was retained in the root canal system regardless of the irrigation technique used (no difference among groups). Furthermore, approximately 50% of the radiolabeled TAP was present circumferentially up to 350 μm within the dentin. Conversely, up to 98% of the radiolabeled intracanal calcium hydroxide was removed, and most residual medicament was found present in the initial 50 μm of dentin. Current irrigation techniques do not effectively remove TAP from root canal systems, possibly because of its penetration and binding into dentin. However, calcium hydroxide is effectively removed with significant less residual presence. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. Stability of a novel corticosteroid nasal irrigation solution: betamethasone 17-valerate added to extemporaneously prepared nasal irrigation solutions.

    PubMed

    Ong, Kheng Yong; Lim, Wei Ching; Ooi, Shing Ming; Loh, Zhi Hui; Kong, Ming Chai; Chan, Lai Wah; Heng, Paul Wan Sia

    2017-05-01

    There are no commercially available nasal irrigation solutions containing corticosteroids. Instead, such preparations are extemporaneously prepared by adding existing corticosteroid formulations to nasal irrigation solutions. The stability of the corticosteroid betamethasone 17-valerate (B17V), in nasal irrigation solutions of different compositions and pH and stored under different temperatures, was studied to determine the optimal choice of solution and storage conditions. Triplicate extemporaneous preparations made with B17V were prepared by adding a predetermined volume of B17V lotion to each nasal irrigation solution: normal saline (NS), sodium bicarbonate (NaHCO 3 ) powder dissolved in tap water, and a commercially available powder mixture (FLO Sinus Care Powder), dissolved in tap water or pre-boiled tap water. Preparations were stored at 30°C and 4°C. Sampling was carried out at 0, 1, 2, 6, and 24 hours. The concentrations of B17V and its degradation compound, betamethasone 21-valerate (B21V), were determined by high-performance liquid chromatography. Preparations stored at 30°C contained a lower amount of B17V and higher amount of B21V than those stored at 4°C. B17V stability in nasal irrigation solutions decreased in the following order: NS, FLO in fresh tap water, FLO in pre-boiled tap water, and NaHCO 3 . The degradation rate of B17V increased with higher storage temperature and higher pH. B17V is most stable when added to NS and least stable in NaHCO 3 solution. FLO solution prepared with either cooled boiled water or tap water is an alternative if administered immediately. Storage at 4°C can better preserve stability of B17V, over a period of 24 hours. © 2017 ARS-AAOA, LLC.

  12. Water quality risks of 'improved' water sources: evidence from Cambodia.

    PubMed

    Shaheed, A; Orgill, J; Ratana, C; Montgomery, M A; Jeuland, M A; Brown, J

    2014-02-01

    The objective of this study was to investigate the quality of on-plot piped water and rainwater at the point of consumption in an area with rapidly expanding coverage of 'improved' water sources. Cross-sectional study of 914 peri-urban households in Kandal Province, Cambodia, between July-August 2011. We collected data from all households on water management, drinking water quality and factors potentially related to post-collection water contamination. Drinking water samples were taken directly from a subsample of household taps (n = 143), stored tap water (n = 124), other stored water (n = 92) and treated stored water (n = 79) for basic water quality analysis for Escherichia coli and other parameters. Household drinking water management was complex, with different sources used at any given time and across seasons. Rainwater was the most commonly used drinking water source. Households mixed different water sources in storage containers, including 'improved' with 'unimproved' sources. Piped water from taps deteriorated during storage (P < 0.0005), from 520 cfu/100 ml (coefficient of variation, CV: 5.7) E. coli to 1100 cfu/100 ml (CV: 3.4). Stored non-piped water (primarily rainwater) had a mean E. coli count of 1500 cfu/100 ml (CV: 4.1), not significantly different from stored piped water (P = 0.20). Microbial contamination of stored water was significantly associated with observed storage and handling practices, including dipping hands or receptacles in water (P < 0.005), and having an uncovered storage container (P = 0.052). The microbial quality of 'improved' water sources in our study area was not maintained at the point of consumption, possibly due to a combination of mixing water sources at the household level, unsafe storage and handling practices, and inadequately treated piped-to-plot water. These results have implications for refining international targets for safe drinking water access as well as the assumptions underlying global burden of disease estimates, which posit that 'improved' sources pose minimal risks of diarrhoeal diseases. © 2013 John Wiley & Sons Ltd.

  13. MONITORING FOR METHYLOBACTERIUM IN WATER SYSTEMS - Letter to the Editor

    EPA Science Inventory

    Methylobacteria are slow growing pink-pigmented organisms that have been reported to be opportunistic pathogens in immunocompromised patients. Methylthylobacterium mesophilicum and M. zatmanii have been the two most commonly reported species isolated in clinical samples. Tap wate...

  14. Cholera Outbreaks in Urban Bangladesh In 2011

    PubMed Central

    Haque, Farhana; Hossain, M. Jahangir; Kundu, Subodh Kumar; Naser, Abu Mohd.; Rahman, Mahmudur; Luby, Stephen P.

    2015-01-01

    Background In 2011, a multidisciplinary team investigated two diarrhoea outbreaks affecting urban Bangladeshi communities from the districts of Bogra and Kishorganj to identify etiology, pathways of transmission, and factors contributing to these outbreaks. Methods We defined case-patients with severe diarrhoea as residents from affected communities admitted with ≥3 loose stools per day. We listed case-patients, interviewed and examined them, and collected rectal swabs. We visited the affected communities to explore the water and sanitation infrastructure. We tested the microbial load of water samples from selected case household taps, tube wells, and pump stations. We conducted anthropological investigations to understand community perceptions regarding the outbreaks. Results We identified 21 case-patients from Bogra and 84 from Kishorganj. The median age in Bogra was 23 years, and 21 years in Kishorganj. There were no reported deaths. We isolated Vibrio in 29% (5/17) of rectal swabs from Bogra and in 40% (8/20) from Kishorganj. We found Vibrio in 1/8 tap water samples from Bogra and in both of the samples from Kishorganj. We did not find Vibrio in water samples from pumps or tube wells in either outbreak. Ground water extracted through deep tube wells was supplied intermittently through interconnected pipes without treatment in both areas. We found leakages in the water pipes in Bogra, and in Kishorganj water pipes passed through open sewers. Conclusion The rapid onset of severe diarrhoea predominantly affecting adults and the isolation of cholera in rectal swabs confirmed that these outbreaks were caused by Vibrio cholerae. The detection of Vibrio in water samples organisms from taps but not from pumps or tube wells, suggested contamination within the pipes. Safe water provision is difficult in municipalities where supply is intermittent, and where pipes commonly leak. Research to develop and evaluate water purification strategies could identify appropriate approaches for ensuring safe drinking water in resource-poor cities. PMID:26702366

  15. Cholera Outbreaks in Urban Bangladesh In 2011.

    PubMed

    Haque, Farhana; Hossain, M Jahangir; Kundu, Subodh Kumar; Naser, Abu Mohd; Rahman, Mahmudur; Luby, Stephen P

    In 2011, a multidisciplinary team investigated two diarrhoea outbreaks affecting urban Bangladeshi communities from the districts of Bogra and Kishorganj to identify etiology, pathways of transmission, and factors contributing to these outbreaks. We defined case-patients with severe diarrhoea as residents from affected communities admitted with ≥3 loose stools per day. We listed case-patients, interviewed and examined them, and collected rectal swabs. We visited the affected communities to explore the water and sanitation infrastructure. We tested the microbial load of water samples from selected case household taps, tube wells, and pump stations. We conducted anthropological investigations to understand community perceptions regarding the outbreaks. We identified 21 case-patients from Bogra and 84 from Kishorganj. The median age in Bogra was 23 years, and 21 years in Kishorganj. There were no reported deaths. We isolated Vibrio in 29% (5/17) of rectal swabs from Bogra and in 40% (8/20) from Kishorganj. We found Vibrio in 1/8 tap water samples from Bogra and in both of the samples from Kishorganj. We did not find Vibrio in water samples from pumps or tube wells in either outbreak. Ground water extracted through deep tube wells was supplied intermittently through interconnected pipes without treatment in both areas. We found leakages in the water pipes in Bogra, and in Kishorganj water pipes passed through open sewers. The rapid onset of severe diarrhoea predominantly affecting adults and the isolation of cholera in rectal swabs confirmed that these outbreaks were caused by Vibrio cholerae . The detection of Vibrio in water samples organisms from taps but not from pumps or tube wells, suggested contamination within the pipes. Safe water provision is difficult in municipalities where supply is intermittent, and where pipes commonly leak. Research to develop and evaluate water purification strategies could identify appropriate approaches for ensuring safe drinking water in resource-poor cities.

  16. Desalinated drinking water in the GCC countries - The need to address consumer perceptions.

    PubMed

    Shomar, Basem; Hawari, Jalal

    2017-10-01

    The Gulf Cooperation Council (GCC) countries consist of Bahrain, Kuwait, Oman, Qatar, Saudi Arabia, and the United Arab Emirates. These countries depend mainly on seawater desalination to meet their water needs. Although great emphasis is given to characterize desalinated water for its physicochemical and microbial properties, e.g. presence of metals, other organic contaminants and for bacteria, sensorial characteristics including smell, taste and color have not received the same attention. This is possibly attributed to the fact that inhabitants of GCC States do not use desalinated tap water for drinking consumption, rather they depend on locally produced or imported bottled water where color, taste and odor are not problematic. To address the consumer needs and perceptions of drinking desalinated water in GCC countries, water quality standards and guidelines, should respond to the public concern about other sensorial characteristics (organoleptic properties) including taste, odor, and trigeminal sensations. Often the root causes of color and smell in water are attributed to the presence of organic and inorganic contaminants and to bacterial growth which is frequently accompanied by the production of metabolites and byproducts that are obnoxious. The unpleasant sensorial problems associated with desalinated drinking tap water may constitute the driving force for most people in GCC countries to depend on bottled water. To encourage people in the GCC countries to consume desalinated tap water, it is essential that water testing include measurements of physicochemical properties, biofilm presence and organoleptic parameters to improve overall water quality. This review highlights the contribution of organoleptics for consumers of desalinated tap water. It extends water quality research to be addressed by standards for organoleptic parameters in desalinated drinking water. Accordingly, consumer awareness and outreach campaigns should be implemented to encourage people to drink tap water in the GCC countries. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Estimation method of finger tapping dynamics using simple magnetic detection system

    NASA Astrophysics Data System (ADS)

    Kandori, Akihiko; Sano, Yuko; Miyashita, Tsuyoshi; Okada, Yoshihisa; Irokawa, Masataka; Shima, Keisuke; Tsuji, Toshio; Yokoe, Masaru; Sakoda, Saburo

    2010-05-01

    We have developed the simple estimation method of a finger tapping dynamics model for investigating muscle resistance and stiffness during tapping movement in normal subjects. We measured finger tapping movements of 207 normal subjects using a magnetic finger tapping detection system. Each subject tapped two fingers in time with a metronome at 1, 2, 3, 4, and 5 Hz. The velocity and acceleration values for both the closing and opening tapping data were used to estimate a finger tapping dynamics model. Using the frequency response of the ratio of acceleration to velocity of the mechanical impedance parameters, we estimated the resistance (friction coefficient) and compliance (stiffness). We found two dynamics models for the maximum open position and tap position. In the maximum open position, the extensor muscle resistance was twice as high as the flexor muscle resistance and males had a higher spring constant. In the tap position, the flexor muscle resistance was much higher than the extensor muscle resistance. This indicates that the tapping dynamics in the maximum open position are controlled by the balance of extensor and flexor muscle friction resistances and the flexor stiffness, and the flexor friction resistance is the main component in the tap position. It can be concluded that our estimation method makes it possible to understand the tapping dynamics.

  18. Assembly and function of the major histocompatibility complex (MHC) I peptide-loading complex are conserved across higher vertebrates.

    PubMed

    Hinz, Andreas; Jedamzick, Johanna; Herbring, Valentina; Fischbach, Hanna; Hartmann, Jessica; Parcej, David; Koch, Joachim; Tampé, Robert

    2014-11-28

    Antigen presentation to cytotoxic T lymphocytes via major histocompatibility complex class I (MHC I) molecules depends on the heterodimeric transporter associated with antigen processing (TAP). For efficient antigen supply to MHC I molecules in the ER, TAP assembles a macromolecular peptide-loading complex (PLC) by recruiting tapasin. In evolution, TAP appeared together with effector cells of adaptive immunity at the transition from jawless to jawed vertebrates and diversified further within the jawed vertebrates. Here, we compared TAP function and interaction with tapasin of a range of species within two classes of jawed vertebrates. We found that avian and mammalian TAP1 and TAP2 form heterodimeric complexes across taxa. Moreover, the extra N-terminal domain TMD0 of mammalian TAP1 and TAP2 as well as avian TAP2 recruits tapasin. Strikingly, however, only TAP1 and TAP2 from the same taxon can form a functional heterodimeric translocation complex. These data demonstrate that the dimerization interface between TAP1 and TAP2 and the tapasin docking sites for PLC assembly are conserved in evolution, whereas elements of antigen translocation diverged later in evolution and are thus taxon specific. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.

  19. Estimation method of finger tapping dynamics using simple magnetic detection system.

    PubMed

    Kandori, Akihiko; Sano, Yuko; Miyashita, Tsuyoshi; Okada, Yoshihisa; Irokawa, Masataka; Shima, Keisuke; Tsuji, Toshio; Yokoe, Masaru; Sakoda, Saburo

    2010-05-01

    We have developed the simple estimation method of a finger tapping dynamics model for investigating muscle resistance and stiffness during tapping movement in normal subjects. We measured finger tapping movements of 207 normal subjects using a magnetic finger tapping detection system. Each subject tapped two fingers in time with a metronome at 1, 2, 3, 4, and 5 Hz. The velocity and acceleration values for both the closing and opening tapping data were used to estimate a finger tapping dynamics model. Using the frequency response of the ratio of acceleration to velocity of the mechanical impedance parameters, we estimated the resistance (friction coefficient) and compliance (stiffness). We found two dynamics models for the maximum open position and tap position. In the maximum open position, the extensor muscle resistance was twice as high as the flexor muscle resistance and males had a higher spring constant. In the tap position, the flexor muscle resistance was much higher than the extensor muscle resistance. This indicates that the tapping dynamics in the maximum open position are controlled by the balance of extensor and flexor muscle friction resistances and the flexor stiffness, and the flexor friction resistance is the main component in the tap position. It can be concluded that our estimation method makes it possible to understand the tapping dynamics.

  20. Molecular characterization of natural biofilms from household taps with different materials: PVC, stainless steel, and cast iron in drinking water distribution system.

    PubMed

    Lin, Wenfang; Yu, Zhisheng; Chen, Xi; Liu, Ruyin; Zhang, Hongxun

    2013-09-01

    Microorganism in drinking water distribution system may colonize in biofilms. Bacterial 16S rRNA gene diversities were analyzed in both water and biofilms grown on taps with three different materials (polyvinyl chloride (PVC), stainless steel, and cast iron) from a local drinking water distribution system. In total, five clone libraries (440 sequences) were obtained. The taxonomic composition of the microbial communities was found to be dominated by members of Proteobacteria (65.9-98.9 %), broadly distributed among the classes Alphaproteobacteria, Betaproteobacteria, and Gammaproteobacteria. Other bacterial groups included Firmicutes, Acidobacteria, Bacteroidetes, Cyanobacteria, and Deinococcus-Thermus. Moreover, a small proportion of unclassified bacteria (3.5-10.6 %) were also found. This investigation revealed that the bacterial communities in biofilms appeared much more diversified than expected and more care should be taken to the taps with high bacterial diversity. Also, regular monitor of outflow water would be useful as potentially pathogenic bacteria were detected. In addition, microbial richness and diversity in taps ranked in the order as: PVC < stainless steel < cast iron. All the results interpreted that PVC would be a potentially suitable material for use as tap component in drinking water distribution system.

  1. Effects of tooth root contact on the stability of orthodontic anchor screws in the maxilla: Comparison between self-drilling and self-tapping methods.

    PubMed

    Iwai, Hiroaki; Motoyoshi, Mitsuru; Uchida, Yasuki; Matsuoka, Miho; Shimizu, Noriyoshi

    2015-04-01

    We evaluated the effects of screw placement angle on the frequency of root contact and the effects of root contact on screw stability, comparing self-drilling and self-tapping methods. In total, 80 patients with 142 screws (diameter, 1.6 mm; length, 8.0 mm) were included. Cone-beam computed tomography images were taken. Cortical bone thickness, interroot distance, shortest distance between the screw and adjacent tooth root, and screw placement angle were measured. The success rates of the screws were 91.5% for the self-drilling method and 94.4% for the self-tapping method (P >0.05). The self-drilling screws tended to contact the distal tooth roots in the right maxilla. In the self-drilling method, the failure rate was significantly higher in the root contact group than in the no-contact group (P <0.05). The success rate was not significantly different between the self-drilling and the self-tapping methods in the maxilla. Avoidance of tooth root contact may improve the success rate more in the self-drilling method than in the self-tapping method. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  2. Traffic Aware Planner for Cockpit-Based Trajectory Optimization

    NASA Technical Reports Server (NTRS)

    Woods, Sharon E.; Vivona, Robert A.; Henderson, Jeffrey; Wing, David J.; Burke, Kelly A.

    2016-01-01

    The Traffic Aware Planner (TAP) software application is a cockpit-based advisory tool designed to be hosted on an Electronic Flight Bag and to enable and test the NASA concept of Traffic Aware Strategic Aircrew Requests (TASAR). The TASAR concept provides pilots with optimized route changes (including altitude) that reduce fuel burn and/or flight time, avoid interactions with known traffic, weather and restricted airspace, and may be used by the pilots to request a route and/or altitude change from Air Traffic Control. Developed using an iterative process, TAP's latest improvements include human-machine interface design upgrades and added functionality based on the results of human-in-the-loop simulation experiments and flight trials. Architectural improvements have been implemented to prepare the system for operational-use trials with partner commercial airlines. Future iterations will enhance coordination with airline dispatch and add functionality to improve the acceptability of TAP-generated route-change requests to pilots, dispatchers, and air traffic controllers.

  3. Method and Apparatus for Generating Flight-Optimizing Trajectories

    NASA Technical Reports Server (NTRS)

    Ballin, Mark G. (Inventor); Wing, David J. (Inventor)

    2015-01-01

    An apparatus for generating flight-optimizing trajectories for a first aircraft includes a receiver capable of receiving second trajectory information associated with at least one second aircraft. The apparatus also includes a traffic aware planner (TAP) module operably connected to the receiver to receive the second trajectory information. The apparatus also includes at least one internal input device on board the first aircraft to receive first trajectory information associated with the first aircraft and a TAP application capable of calculating an optimal trajectory for the first aircraft based at least on the first trajectory information and the second trajectory information. The optimal trajectory at least avoids conflicts between the first trajectory information and the second trajectory information.

  4. Composition and Dynamics of Bacterial Communities of a Drinking Water Supply System as Assessed by RNA- and DNA-Based 16S rRNA Gene Fingerprinting

    PubMed Central

    Eichler, Stefan; Christen, Richard; Höltje, Claudia; Westphal, Petra; Bötel, Julia; Brettar, Ingrid; Mehling, Arndt; Höfle, Manfred G.

    2006-01-01

    Bacterial community dynamics of a whole drinking water supply system (DWSS) were studied from source to tap. Raw water for this DWSS is provided by two reservoirs with different water characteristics in the Harz mountains of Northern Germany. Samples were taken after different steps of treatment of raw water (i.e., flocculation, sand filtration, and chlorination) and at different points along the supply system to the tap. RNA and DNA were extracted from the sampled water. The 16S rRNA or its genes were partially amplified by reverse transcription-PCR or PCR and analyzed by single-strand conformation polymorphism community fingerprints. The bacterial community structures of the raw water samples from the two reservoirs were very different, but no major changes of these structures occurred after flocculation and sand filtration. Chlorination of the processed raw water strongly affected bacterial community structure, as reflected by the RNA-based fingerprints. This effect was less pronounced for the DNA-based fingerprints. After chlorination, the bacterial community remained rather constant from the storage containers to the tap. Furthermore, the community structure of the tap water did not change substantially for several months. Community composition was assessed by sequencing of abundant bands and phylogenetic analysis of the sequences obtained. The taxonomic compositions of the bacterial communities from both reservoirs were very different at the species level due to their different limnologies. On the other hand, major taxonomic groups, well known to occur in freshwater, such as Alphaproteobacteria, Betaproteobacteria, and Bacteroidetes, were found in both reservoirs. Significant differences in the detection of the major groups were observed between DNA-based and RNA-based fingerprints irrespective of the reservoir. Chlorination of the drinking water seemed to promote growth of nitrifying bacteria. Detailed analysis of the community dynamics of the whole DWSS revealed a significant influence of both source waters on the overall composition of the drinking water microflora and demonstrated the relevance of the raw water microflora for the drinking water microflora provided to the end user. PMID:16517632

  5. A Novel Liquid-Liquid Extraction for the Determination of Sertraline in Tap Water and Waste Water at Trace Levels by GC-MS.

    PubMed

    Koçoğlu, Elif Seda; Bakırdere, Sezgin; Keyf, Seyfullah

    2017-09-01

    A simple, green and fast analytical method was developed for the determination of sertraline in tap and waste water samples at trace levels by using supportive liquid-liquid extraction with gas chromatography-mass spectrometry. Different parameters affecting extraction efficiency such as types and volumes of extraction and supporter solvents, extraction period, salt type and amount were optimized to get lower detection limits. Ethyl acetate was selected as optimum extraction solvent. In order to improve the precision, anthracene-D10 was used as an internal standard. The calibration plot of sertraline was linear from 1.0 to 1000 ng/mL with a correlation coefficient of 0.999. The limit of detection value under the optimum conditions was found to be 0.43 ng/mL. In real sample measurements, spiking experiments were performed to check the reliability of the method for these matrices. The spiking experiments yielded satisfactory recoveries of 91.19 ± 2.48%, 90.48 ± 5.19% and 95.46 ± 6.56% for 100, 250 and 500 ng/mL sertraline for tap water, and 85.80 ± 2.15% and 92.43 ± 4.02% for 250 and 500 ng/mL sertraline for waste water.

  6. Detection of ultra-low levels of DNA changes by drinking water: epidemiologically important finding.

    PubMed

    Kumari, Parmila; Kamiseki, Meiko; Biyani, Manish; Suzuki, Miho; Nemoto, Naoto; Aita, Takuyo; Nishigaki, Koichi

    2015-02-01

    The safety of drinking water is essential to our health. In this context, the mutagenicity of water needs to be checked strictly. However, from the methodological limit, the lower concentration (less than parts per million) of mutagenicity could not be detected, though there have been of interest in the effect of less concentration mutagens. Here, we describe a highly sensitive mutation assay that detects mutagens at the ppb level, termed genome profiling-based mutation assay (GPMA). This consists of two steps; (i) Escherichia coli culture in the medium with/without mutagens and (ii) Genome profiling (GP) method (an integrated method of random PCR, temperature gradient gel electrophoresis and computer-aided normalization). Owing to high sensitivity of this method, very low concentration of mutagens in tap water could be directly detected without introducing burdensome concentration processes, enabling rapid measurement of low concentration samples. Less expectedly, all of the tap waters tested (22 samples) were shown to be significantly mutagenic while mineral waters were not. Resultantly, this article informs two facts that the GPMA method is competent to measure the mutagenicity of waters directly and the experimental results supported the former reports that the city tap waters contain very low level of mutagenicity reagent trihalomethanes. © The Authors 2014. Published by Oxford University Press on behalf of the Japanese Biochemical Society. All rights reserved.

  7. Ten-year review of rating scales. III: scales assessing suicidality, cognitive style, and self-esteem.

    PubMed

    Winters, Nancy C; Myers, Kathleen; Proud, Laura

    2002-10-01

    This is the third article in a series of 10-year reviews of rating scales. Here, the authors review scales that are useful in tapping the affective disturbances experienced with various psychiatric disorders, including suicidality, cognitive style, and self-esteem. The authors sampled articles incorporating these constructs over the past 25 years and selected scales with established uses or new development. Those presented here have adequate psychometric properties and high utility for efficiently elucidating youths' functioning, plus either wide literature citations or a special niche. These scales were developed bimodally. Many were developed in the 1980s when internalizing disorders were elucidated, but there has been a resurgence of interest in these constructs. Scales assessing suicidality have clear constructs, whereas scales of cognitive style demonstrate deficits in developmental relevance, and scales of self-esteem suffer from lax constructs. The constructs underlying these scales tap core symptoms of internalizing disorders, mediate the expression of affective disturbances associated with various disorders, and depict the impairments resulting from these disorders. Overall, the psychometrics of these scales are adequate. These scales provide a broader representation of youths' functioning than that conveyed with diagnostic scales alone.

  8. Plumbing system shock absorbers as a source of Legionella pneumophila.

    PubMed

    Memish, Z A; Oxley, C; Contant, J; Garber, G E

    1992-12-01

    Water distribution systems have been demonstrated to be a major source of nosocomial legionellosis. We describe an outbreak in our institution in which a novel source of Legionella pneumophila was identified in the plumbing system. After an outbreak of 10 cases of legionellosis in our hospital, recommended measures including superheating of the hot water to 80 degrees C, hyperchlorination to 2 ppm, and flushing resulted in no new cases in the following 5 years. Recently, despite these control measures, three new cases occurred. Surveillance cultures of shower heads and water tanks were negative; cultures of tap water samples remained positive. This prompted a search for another reservoir. Shock absorbers installed within water pipes to decrease noise were suspected. One hundred twenty-five shock absorbers were removed and cultured. A total of 13 (10%) yielded heavy growth of L. pneumophila (serogroup 1). Since their removal, no new cases have been found and the percentage of positive results of random tap water culture has dropped from 20% to 5%. This is the first report that identifies shock absorbers as a possible reservoir for L. pneumophila. We recommend that institutions with endemic legionellosis assess the water system for possible removal of shock absorbers.

  9. Protective Coatings for Steel Structures: Laboratory and Field Evaluation and Development of a Model Coating Guide Specification.

    DTIC Science & Technology

    1980-01-01

    coated with carnauba wax . Samples were exposed for 30 test cycles. The samples were cemoved from the chamber, washed with tap water, then with distil...vertically with wax -coated hooks, the bottoms of the specimens being about 12 cm from the chamber floor. The backs and edges of all specimens were

  10. Improved symbol rate identification method for on-off keying and advanced modulation format signals based on asynchronous delayed sampling

    NASA Astrophysics Data System (ADS)

    Cui, Sheng; Jin, Shang; Xia, Wenjuan; Ke, Changjian; Liu, Deming

    2015-11-01

    Symbol rate identification (SRI) based on asynchronous delayed sampling is accurate, cost-effective and robust to impairments. For on-off keying (OOK) signals the symbol rate can be derived from the periodicity of the second-order autocorrelation function (ACF2) of the delay tap samples. But it is found that when applied this method to advanced modulation format signals with auxiliary amplitude modulation (AAM), incorrect results may be produced because AAM has significant impact on ACF2 periodicity, which makes the symbol period harder or even unable to be correctly identified. In this paper it is demonstrated that for these signals the first order autocorrelation function (ACF1) has stronger periodicity and can be used to replace ACF2 to produce more accurate and robust results. Utilizing the characteristics of the ACFs, an improved SRI method is proposed to accommodate both OOK and advanced modulation formant signals in a transparent manner. Furthermore it is proposed that by minimizing the peak to average ratio (PAPR) of the delay tap samples with an additional tunable dispersion compensator (TDC) the limited dispersion tolerance can be expanded to desired values.

  11. Validation of the Self-Beliefs Related to Social Anxiety Scale

    PubMed Central

    Moulds, Michelle L.; Rapee, Ronald M.

    2014-01-01

    The importance of self-beliefs in prominent models of social phobia has led to the development of measures that tap this cognitive construct. The Self-Beliefs Related to Social Anxiety (SBSA) Scale is one such measure and taps the three maladaptive belief types proposed in Clark and Wells’s model of social phobia. This study aimed to replicate and extend previous research on the psychometric properties of the SBSA. Replicating previous research, in an (undiagnosed) undergraduate sample (n = 235), the SBSA was found to have a correlated three-factor structure using confirmatory factor analyses, and the SBSA and its subscales demonstrated good internal consistency and test–retest reliability. The SBSA and its subscales also had unique relationships with social anxiety and depression, the majority of which replicated previous research. Extending previous research, the SBSA and its subscales showed good incremental validity in the undergraduate sample and good discriminative validity using the undergraduate sample and a sample of individuals with social phobia (n = 33). The SBSA’s strong theoretical basis and the findings of this study suggest that the SBSA is an ideal research and clinical tool to assess the cognitions characteristic of social phobia. PMID:23575344

  12. Human health impacts of drinking water (surface and ground) pollution Dakahlyia Governorate, Egypt

    NASA Astrophysics Data System (ADS)

    Mandour, R. A.

    2012-09-01

    This study was done on 30 drinking tap water samples (surface and ground) and 30 urine samples taken from patients who attended some of Dakahlyia governorate hospitals. These patients were complaining of poor-quality tap water in their houses, which was confirmed by this study that drinking water is contaminated with trace elements in some of the studied areas. The aim of this study was to determine the relationship between the contaminant drinking water (surface and ground) in Dakahlyia governorate and its impact on human health. This study reports the relationship between nickel and hair loss, obviously shown in water and urine samples. Renal failure cases were related to lead and cadmium contaminated drinking water, where compatibilities in results of water and urine samples were observed. Also, liver cirrhosis cases were related to iron-contaminated drinking water. Studies of these diseases suggest that abnormal incidence in specific areas is related to industrial wastes and agricultural activities that have released hazardous and toxic materials in the drinking water and thereby led to its contamination in these areas. We conclude that trace elements should be removed from drinking water for human safety.

  13. Validation of the self-beliefs related to social anxiety scale: a replication and extension.

    PubMed

    Wong, Quincy J J; Moulds, Michelle L; Rapee, Ronald M

    2014-06-01

    The importance of self-beliefs in prominent models of social phobia has led to the development of measures that tap this cognitive construct. The Self-Beliefs Related to Social Anxiety (SBSA) Scale is one such measure and taps the three maladaptive belief types proposed in Clark and Wells's model of social phobia. This study aimed to replicate and extend previous research on the psychometric properties of the SBSA. Replicating previous research, in an (undiagnosed) undergraduate sample (n = 235), the SBSA was found to have a correlated three-factor structure using confirmatory factor analyses, and the SBSA and its subscales demonstrated good internal consistency and test-retest reliability. The SBSA and its subscales also had unique relationships with social anxiety and depression, the majority of which replicated previous research. Extending previous research, the SBSA and its subscales showed good incremental validity in the undergraduate sample and good discriminative validity using the undergraduate sample and a sample of individuals with social phobia (n = 33). The SBSA's strong theoretical basis and the findings of this study suggest that the SBSA is an ideal research and clinical tool to assess the cognitions characteristic of social phobia. © The Author(s) 2013.

  14. An interactive videogame for arm and hand exercise in people with Parkinson's disease: A randomized controlled trial.

    PubMed

    Allen, Natalie E; Song, Jooeun; Paul, Serene S; Smith, Stuart; O'Duffy, Jonathan; Schmidt, Matthew; Love, Rachelle; Sherrington, Catherine; Canning, Colleen G

    2017-08-01

    People with Parkinson's disease (PD) have difficulty performing upper extremity (UE) activities. The aim of this study was to investigate if exergames targeting the UE improve arm and hand activities and impairments and to establish the acceptability and feasibility of these games in people with PD. Two tablet-based exergames were developed which were controlled with finger movements or unimanual whole arm movements. Participants with PD were randomized to an exergame (n = 19) or control (n = 19) group. The exergame group performed UE exergames at home, 3 times per week for 12 weeks. The primary outcome measure was the nine hole peg test. Secondary outcomes included measures of UE activities and impairments, including the tapping test [speed (taps/60s), and error (weighted error score/speed)]. There were no between group differences in the nine hole peg test, or in any secondary outcome measures except for the tapping test. Horizontal tapping test results showed that exergame participants improved their speed (mean difference = 10.9 taps/60s, p < 0.001) but increased error (mean difference = 0.03, p = 0.03) compared to the control group. Participants enjoyed the games and improved in their ability to play the games. There were no adverse events. The UE exergames were acceptable and safe, but did not translate to improvement in functional activities. It is likely that the requirement of the games resulted in increased movement speed at the detriment of accuracy. The design of exergames should consider task specificity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Vertical Finger Displacement Is Reduced in Index Finger Tapping During Repeated Bout Rate Enhancement.

    PubMed

    Mora-Jensen, Mark Holten; Madeleine, Pascal; Hansen, Ernst Albin

    2017-10-01

    The present study analyzed (a) whether a recently reported phenomenon of repeated bout rate enhancement in finger tapping (i.e., a cumulating increase in freely chosen finger tapping frequency following submaximal muscle activation in the form of externally unloaded voluntary tapping) could be replicated and (b) the hypotheses that the faster tapping was accompanied by changed vertical displacement of the fingertip and changed peak force during tapping. Right-handed, healthy, and recreationally active individuals (n = 24) performed two 3-min index finger tapping bouts at freely chosen tapping frequency, separated by 10-min rest. The recently reported phenomenon of repeated bout rate enhancement was replicated. The faster tapping (8.8 ± 18.7 taps/min, corresponding to 6.0 ± 11.0%, p = .033) was accompanied by reduced vertical displacement (1.6 ± 2.9 mm, corresponding to 6.3 ± 14.9%, p = .012) of the fingertip. Concurrently, peak force was unchanged. The present study points at separate control mechanisms governing kinematics and kinetics during finger tapping.

  16. Preliminary human health risk assessment of arsenic and fluoride in tap water from Zacatecas, México.

    PubMed

    Martínez-Acuña, Mónica I; Mercado-Reyes, Marisa; Alegría-Torres, Jorge A; Mejía-Saavedra, José J

    2016-08-01

    Zacatecas state is located in the central area of Mexico, where the underground water contains elevated quantities of natural arsenic and fluoride. In order to estimate health risk associated with human exposure to these pollutants, tap water samples from the southern-central region of the state were analyzed. Ninety percent of the samples exceeded the levels of arsenic established by the World Health Organization (WHO) of 0.01 mg/L and 43 % exceeded the limit established by the NOM-127-SSA1(1) of 0.025 mg/L. Forty-three percent of the samples had fluoride levels above the Mexican regulation limit of 1.5 mg/L (NOM-127-SSA1). We used WHO and EPA's health risk assessment method, we estimated 80 % of the inhabitants of sites studied could be exposed to arsenic levels higher than those recommended by EPA and the WHO, 22 % could be exposed to fluoride levels higher than those recommended by EPA, and 16 % of the local population may be in risk of suffering dental fluorosis.

  17. Memo Clarifying Recommended Tap Sampling Procedures for the Lead and Copper Rule

    EPA Pesticide Factsheets

    EPA has recently published a memo to provide recommendations on how public water systems should address the removal of cleaning aerators, pre-stagnation flushing, and bottle configuration for the purpose of the Lead and Copper Rule.

  18. Multimethod Personality Profile Assessment Methodology: Alcohol Abusers versus Nonalcoholic Controls.

    DTIC Science & Technology

    1982-12-01

    following: oral fixation with passive, dependent features; psychopathy ; low frustration tolerance; low perseverance; guilt and anxiety; egocentricity...research findings of elevated scale 4 with alcoholic samples, the psychopathy /sociopathy personality domain, as tapped by the MMPI/Pd items, warranted

  19. Age-related changes in the bimanual advantage and in brain oscillatory activity during tapping movements suggest a decline in processing sensory reafference.

    PubMed

    Sallard, Etienne; Spierer, Lucas; Ludwig, Catherine; Deiber, Marie-Pierre; Barral, Jérôme

    2014-02-01

    Deficits in the processing of sensory reafferences have been suggested as accounting for age-related decline in motor coordination. Whether sensory reafferences are accurately processed can be assessed based on the bimanual advantage in tapping: because of tapping with an additional hand increases kinesthetic reafferences, bimanual tapping is characterized by a reduced inter-tap interval variability than unimanual tapping. A suppression of the bimanual advantage would thus indicate a deficit in sensory reafference. We tested whether elderly indeed show a reduced bimanual advantage by measuring unimanual (UM) and bimanual (BM) self-paced tapping performance in groups of young (n = 29) and old (n = 27) healthy adults. Electroencephalogram was recorded to assess the underlying patterns of oscillatory activity, a neurophysiological mechanism advanced to support the integration of sensory reafferences. Behaviorally, there was a significant interaction between the factors tapping condition and age group at the level of the inter-tap interval variability, driven by a lower variability in BM than UM tapping in the young, but not in the elderly group. This result indicates that in self-paced tapping, the bimanual advantage is absent in elderly. Electrophysiological results revealed an interaction between tapping condition and age group on low beta band (14-20 Hz) activity. Beta activity varied depending on the tapping condition in the elderly but not in the young group. Source estimations localized this effect within left superior parietal and left occipital areas. We interpret our results in terms of engagement of different mechanisms in the elderly depending on the tapping mode: a 'kinesthetic' mechanism for UM and a 'visual imagery' mechanism for BM tapping movement.

  20. Monitoring and removal of residual phthalate esters and pharmaceuticals in the drinking water of Kaohsiung City, Taiwan.

    PubMed

    Yang, Gordon C C; Yen, Chia-Heng; Wang, Chih-Lung

    2014-07-30

    This study monitored the occurrence and removal efficiencies of 8 phthalate esters (PAEs) and 13 pharmaceuticals present in the drinking water of Kaohsiung City, Taiwan. The simultaneous electrocoagulation and electrofiltration (EC/EF) process was used to remove the contaminants. To this end, a monitoring program was conducted and a novel laboratory-prepared tubular carbon nanofiber/carbon/alumina composite membrane (TCCACM) was incorporated into the EC/EF treatment module (collectively designated as "TCCACM-EC/EF treatment module") to remove the abovementioned compounds from water samples. The monitoring results showed that the concentrations of PAEs were lower in water samples from drinking fountains as compared with tap water samples. No significant differences were found between the concentrations of pharmaceuticals in the two types of water samples. Under optimal operating conditions, the TCCACM-EC/EF treatment module yielded the lowest residual concentrations, ranging from not detected (ND) to 52ng/L for PAEs and pharmaceuticals of concern in the tap water samples. Moreover, the performance of the TCCACM-EC/EF treatment module is comparable with a series of treatment units employed for the drinking fountain water treatment system. The relevant removal mechanisms involved in the TCCACM-EC/EF treatment module were also discussed in this work. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Quantitative modeling of peptide binding to TAP using support vector machine.

    PubMed

    Diez-Rivero, Carmen M; Chenlo, Bernardo; Zuluaga, Pilar; Reche, Pedro A

    2010-01-01

    The transport of peptides to the endoplasmic reticulum by the transporter associated with antigen processing (TAP) is a necessary step towards determining CD8 T cell epitopes. In this work, we have studied the predictive performance of support vector machine models trained on single residue positions and residue combinations drawn from a large dataset consisting of 613 nonamer peptides of known affinity to TAP. Predictive performance of these TAP affinity models was evaluated under 10-fold cross-validation experiments and measured using Pearson's correlation coefficients (R(p)). Our results show that every peptide position (P1-P9) contributes to TAP binding (minimum R(p) of 0.26 +/- 0.11 was achieved by a model trained on the P6 residue), although the largest contributions to binding correspond to the C-terminal end (R(p) = 0.68 +/- 0.06) and the P1 (R(p) = 0.51 +/- 0.09) and P2 (0.57 +/- 0.08) residues of the peptide. Training the models on additional peptide residues generally improved their predictive performance and a maximum correlation (R(p) = 0.89 +/- 0.03) was achieved by a model trained on the full-length sequences or a residue selection consisting of the first 5 N- and last 3 C-terminal residues of the peptides included in the training set. A system for predicting the binding affinity of peptides to TAP using the methods described here is readily available for free public use at http://imed.med.ucm.es/Tools/tapreg/. (c) 2009 Wiley-Liss, Inc.

  2. Contribution of type IV pili to the virulence of Aeromonas salmonicida subsp. salmonicida in Atlantic salmon (Salmo salar L.).

    PubMed

    Boyd, Jessica M; Dacanay, Andrew; Knickle, Leah C; Touhami, Ahmed; Brown, Laura L; Jericho, Manfred H; Johnson, Stewart C; Reith, Michael

    2008-04-01

    Aeromonas salmonicida subsp. salmonicida, a bacterial pathogen of Atlantic salmon, has no visible pili, yet its genome contains genes for three type IV pilus systems. One system, Tap, is similar to the Pseudomonas aeruginosa Pil system, and a second, Flp, resembles the Actinobacillus actinomycetemcomitans Flp pilus, while the third has homology to the mannose-sensitive hemagglutinin pilus of Vibrio cholerae. The latter system is likely nonfunctional since eight genes, including the gene encoding the main pilin subunit, are deleted compared with the orthologous V. cholerae locus. The first two systems were characterized to investigate their expression and role in pathogenesis. The pili of A. salmonicida subsp. salmonicida were imaged using atomic force microscopy and Tap- and Flp-overexpressing strains. The Tap pili appeared to be polar, while the Flp pili appeared to be peritrichous. Strains deficient in tap and/or flp were used in live bacterial challenges of Atlantic salmon, which showed that the Tap pilus made a moderate contribution to virulence, while the Flp pilus made little or no contribution. Delivery of the tap mutant by immersion resulted in reduced cumulative morbidity compared with the cumulative morbidity observed with the wild-type strain; however, delivery by intraperitoneal injection resulted in cumulative morbidity similar to that of the wild type. Unlike the pili of other piliated bacterial pathogens, A. salmonicida subsp. salmonicida type IV pili are not absolutely required for virulence in Atlantic salmon. Significant differences in the behavior of the two mutant strains indicated that the two pilus systems are not redundant.

  3. Does the Arrangement of Embedded Text Versus Linked Text in Homework Systems Make a Difference in Students Impressions, Attitudes, and Perceived Learning?

    NASA Astrophysics Data System (ADS)

    Zumalt, Caitlin J.; Williamson, Vickie M.

    2016-10-01

    Students in a first-semester general chemistry course at a large southwestern university completed a 3-week homework assignment using MindTap, a Cengage Learning product. MindTap is the first major electronic system that has homework questions embedded in the text, such that students read a short section of the textbook and then answer a question set. Prior to MindTap, electronic homework systems were stand-alone or contained questions with links to the textbook. Next, students completed two 2-week homework assignments in Online Web Learning (OWL) version 1 also from Cengage Learning. The OWL system shows homework questions with a link to the textbook in a separate window. Both the MindTap and OWL systems contain the same or similar questions. After the students used both homework systems, a survey was given that included Likert-scaled and open-response questions that dealt with students' perceived level of understanding using the different systems, how easy the systems were to use, and the advantages/disadvantages of each system. A delayed survey was given at the end of the second semester of general chemistry, during which students had used OWL for the complete semester. This paper investigates the effects of the arrangement (embedded vs. linked) on student preferences and perceived learning in this pilot study with a 300-person class. Based on the results of the study, it was found that students perceived that they learn more with MindTap and prefer the embedded text in MindTap over the linked text in OWL.

  4. Scanning ion-conductance and atomic force microscope with specialized sphere-shaped nanopippettes

    NASA Astrophysics Data System (ADS)

    Zhukov, M. V.; Sapozhnikov, I. D.; Golubok, A. O.; Chubinskiy-Nadezhdin, V. I.; Komissarenko, F. E.; Lukashenko, S. Y.

    2017-11-01

    A scanning ion-conductance microscope was designed on the basis of scanning probe microscope NanoTutor. The optimal parameters of nanopipettes fabrication were found according to scanning electron microscopy diagnostics, current-distance I (Z) and current-voltage characteristics. A comparison of images of test objects, including biological samples, was carried out in the modes of optical microscopy, atomic force microscopy and scanning ion-conductance microscopy. Sphere-shaped nanopippettes probes were developed and tested to increase the stability of pipettes, reduce invasiveness and improve image quality of atomic force microscopy in tapping mode. The efficiency of sphere-shaped nanopippettes is shown.

  5. Quantitative assessment of finger tapping characteristics in mild cognitive impairment, Alzheimer's disease, and Parkinson's disease.

    PubMed

    Roalf, David R; Rupert, Petra; Mechanic-Hamilton, Dawn; Brennan, Laura; Duda, John E; Weintraub, Daniel; Trojanowski, John Q; Wolk, David; Moberg, Paul J

    2018-06-01

    Fine motor impairments are common in neurodegenerative disorders, yet standardized, quantitative measurements of motor abilities are uncommonly used in neurological practice. Thus, understanding and comparing fine motor abilities across disorders have been limited. The current study compared differences in finger tapping, inter-tap interval, and variability in Alzheimer's disease (AD), Parkinson's disease (PD), mild cognitive impairment (MCI), and healthy older adults (HOA). Finger tapping was measured using a highly sensitive light-diode finger tapper. Total number of finger taps, inter-tap interval, and intra-individual variability (IIV) of finger tapping was measured and compared in AD (n = 131), PD (n = 63), MCI (n = 46), and HOA (n = 62), controlling for age and sex. All patient groups had fine motor impairments relative to HOA. AD and MCI groups produced fewer taps with longer inter-tap interval and higher IIV compared to HOA. The PD group, however, produced more taps with shorter inter-tap interval and higher IIV compared to HOA. Disease-specific changes in fine motor function occur in the most common neurodegenerative diseases. The findings suggest that alterations in finger tapping patterns are common in AD, MCI, and PD. In addition, the present results underscore the importance of motor dysfunction even in neurodegenerative disorders without primary motor symptoms.

  6. Fluoride exposure and indicators of thyroid functioning in the Canadian population: implications for community water fluoridation.

    PubMed

    Barberio, Amanda M; Hosein, F Shaun; Quiñonez, Carlos; McLaren, Lindsay

    2017-10-01

    There are concerns that altered thyroid functioning could be the result of ingesting too much fluoride. Community water fluoridation (CWF) is an important source of fluoride exposure. Our objectives were to examine the association between fluoride exposure and (1) diagnosis of a thyroid condition and (2) indicators of thyroid functioning among a national population-based sample of Canadians. We analysed data from Cycles 2 and 3 of the Canadian Health Measures Survey (CHMS). Logistic regression was used to assess associations between fluoride from urine and tap water samples and the diagnosis of a thyroid condition. Multinomial logistic regression was used to examine the relationship between fluoride exposure and thyroid-stimulating hormone (TSH) level (low/normal/high). Other available variables permitted additional exploratory analyses among the subset of participants for whom we could discern some fluoride exposure from drinking water and/or dental products. There was no evidence of a relationship between fluoride exposure (from urine and tap water) and the diagnosis of a thyroid condition. There was no statistically significant association between fluoride exposure and abnormal (low or high) TSH levels relative to normal TSH levels. Rerunning the models with the sample constrained to the subset of participants for whom we could discern some source(s) of fluoride exposure from drinking water and/or dental products revealed no significant associations. These analyses suggest that, at the population level, fluoride exposure is not associated with impaired thyroid functioning in a time and place where multiple sources of fluoride exposure, including CWF, exist. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Persistence of DNA on clothes after exposure to water for different time periods-a study on bathtub, pond, and river.

    PubMed

    Helmus, Janine; Zorell, Sarah; Bajanowski, Thomas; Poetsch, Micaela

    2018-01-01

    DNA traces on clothes of drowned bodies can provide important evidence for police investigations, especially in cases of suspected suicides or homicides. However, it is generally assumed that the water "erodes" a large part of the DNA depending especially on the exposure time. In forensic casework, DNA of suspects could be found frequently on clothes of drowned bodies after hours, sometimes days of exposure to water. This study was conducted to attempt a general statement about the conditions under which sufficient DNA remains can be expected for molecular genetic analysis. For this purpose, different scenarios were designed including DNA from three to five people, different types of waters (tap, pond, bathtub and river) for various time periods, with higher water pressure, different temperature, and soapy water (bathtub). Epithelial cells and blood cells were mounted on cotton cloths, and the DNA left after exposure was analyzed using the Powerplex® ESX17fast kit. In the indoor experiments, complete profiles could be seen even after 10 min rinsing of clothes under the tap and after 1 week in the bathtub. Outdoors, the results differed considerably between summer and winter as well as between pond and river. The longest exposure time still resulting in a complete profile was 2 weeks for a sample with skin cells in the pond during winter. In summer, the time period for erasing the bulk of DNA was 4 hours regarding epithelial samples and more than 1 day for blood samples in pond and river environments. All in all, the results demonstrate that DNA could still be recovered from clothes exposed to water for more than 1 week.

  8. A case-control study on association of proteasome subunit beta 8 (PSMB8) and transporter associated with antigen processing 1 (TAP1) polymorphisms and their transcript levels in vitiligo from Gujarat

    PubMed Central

    Jadeja, Shahnawaz D.; Mansuri, Mohmmad Shoab; Singh, Mala; Dwivedi, Mitesh; Laddha, Naresh C.

    2017-01-01

    Background Autoimmunity has been implicated in the destruction of melanocytes from vitiligo skin. Major histocompatibility complex (MHC) class-II linked genes proteasome subunit beta 8 (PSMB8) and transporter associated with antigen processing 1 (TAP1), involved in antigen processing and presentation have been reported to be associated with several autoimmune diseases including vitiligo. Objectives To explore PSMB8 rs2071464 and TAP1 rs1135216 single nucleotide polymorphisms and to estimate the expression of PSMB8 and TAP1 in patients with vitiligo and unaffected controls from Gujarat. Methods PSMB8 rs2071464 polymorphism was genotyped using polymerase chain reaction- restriction fragment length polymorphism (PCR-RFLP) and TAP1 rs1135216 polymorphism was genotyped by amplification refractory mutation system-polymerase chain reaction (ARMS-PCR) in 378 patients with vitiligo and 509 controls. Transcript levels of PSMB8 and TAP1 were measured in the PBMCs of 91 patients and 96 controls by using qPCR. Protein levels of PSMB8 were also determined by Western blot analysis. Results The frequency of ‘TT’ genotype of PSMB8 polymorphism was significantly lowered in patients with generalized and active vitiligo (p = 0.019 and p = 0.005) as compared to controls suggesting its association with the activity of the disease. However, TAP1 polymorphism was not associated with vitiligo susceptibility. A significant decrease in expression of PSMB8 at both transcript level (p = 0.002) as well as protein level (p = 0.0460) was observed in vitiligo patients as compared to controls. No significant difference was observed between patients and controls for TAP1 transcripts (p = 0.553). Interestingly, individuals with the susceptible CC genotype of PSMB8 polymorphism showed significantly reduced PSMB8 transcript level as compared to that of CT and TT genotypes (p = 0.009 and p = 0.003 respectively). Conclusions PSMB8 rs2071464 was associated with generalized and active vitiligo from Gujarat whereas TAP1 rs1135216 showed no association. The down-regulation of PSMB8 in patients with risk genotype ‘CC’ advocates the vital role of PSMB8 in the autoimmune basis of vitiligo. PMID:28700671

  9. Bimanual tapping of a syncopated rhythm reveals hemispheric preferences for relative movement frequencies.

    PubMed

    Pflug, Anja; Gompf, Florian; Kell, Christian Alexander

    2017-08-01

    In bimanual multifrequency tapping, right-handers commonly use the right hand to tap the relatively higher rate and the left hand to tap the relatively lower rate. This could be due to hemispheric specializations for the processing of relative frequencies. An extension of the double-filtering-by-frequency theory to motor control proposes a left hemispheric specialization for the control of relatively high and a right hemispheric specialization for the control of relatively low tapping rates. We investigated timing variability and rhythmic accentuation in right handers tapping mono- and multifrequent bimanual rhythms to test the predictions of the double-filtering-by-frequency theory. Yet, hemispheric specializations for the processing of relative tapping rates could be masked by a left hemispheric dominance for the control of known sequences. Tapping was thus either performed in an overlearned quadruple meter (tap of the slow rhythm on the first auditory beat) or in a syncopated quadruple meter (tap of the slow rhythm on the fourth auditory beat). Independent of syncopation, the right hand outperformed the left hand in timing accuracy for fast tapping. A left hand timing benefit for slow tapping rates as predicted by the double-filtering-by-frequency theory was only found in the syncopated tapping group. This suggests a right hemisphere preference for the control of slow tapping rates when rhythms are not overlearned. Error rates indicate that overlearned rhythms represent hierarchically structured meters that are controlled by a single timer that could potentially reside in the left hemisphere. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Developmental Trajectory of Motor Deficits in Preschool Children with ADHD

    PubMed Central

    Sweeney, Kristie L; Ryan, Matthew; Schneider, Heather; Ferenc, Lisa; Denckla, Martha Bridge; Mahone, E. Mark

    2018-01-01

    Motor deficits persisting into childhood (>7 years) are associated with increased executive and cognitive dysfunction, likely due to parallel neural circuitry. This study assessed the longitudinal trajectory of motor deficits in preschool children with ADHD, compared to typically developing (TD) children, in order to identify individuals at risk for anomalous neurological development. Participants included 47 children (21 ADHD, 26 TD) ages 4–7 years who participated in three visits (V1, V2, V3), each one year apart (V1=48–71 months, V2=60–83 months, V3=72–95 months). Motor variables assessed included speed (finger tapping and sequencing), total overflow, and axial movements from the Revised Physical and Neurological Examination for Subtle Signs (PANESS). Effects for group, visit, and group-by-visit interaction were examined. There were significant effects for group (favoring TD) for finger tapping speed and total axial movements, visit (performance improving with age for all 4 variables), and a significant group-by-visit interaction for finger tapping speed. Motor speed (repetitive finger tapping) and quality of axial movements are sensitive markers of anomalous motor development associated with ADHD in children as young as 4 years. Conversely, motor overflow and finger sequencing speed may be less sensitive in preschool, due to ongoing wide variations in attainment of these milestones. PMID:29757012

  11. Perfluoroalkyl substances assessment in drinking waters from Brazil, France and Spain.

    PubMed

    Schwanz, Thiago G; Llorca, Marta; Farré, Marinella; Barceló, Damià

    2016-01-01

    Human exposure to perfluoroalkyl substances (PFASs) occurs primarily via dietary intake and drinking water. In this study, 16 PFASs have been assessed in 96 drinking waters (38 bottled waters and 58 samples of tap water) from Brazil, France and Spain. The total daily intake and the risk index (RI) of 16 PFASs through drinking water in Brazil, France and Spain have been estimated. This study was carried out using an analytical method based on an online sample enrichment followed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The quality parameters of the analytical method were satisfactory for the analysis of the 16 selected compounds in drinking waters. Notably, the method limits of detection (MLOD) and method limits of quantification (MLOQ) were in the range of 0.15 to 8.76ng/l and 0.47 to 26.54ng/l, respectively. The results showed that the highest PFASs concentrations were found in tap water samples and the more frequently found compound was perfluorooctanesulfonic acid (PFOS), with mean concentrations of 7.73, 15.33 and 15.83ng/l in French, Spanish and Brazilian samples, respectively. In addition, PFOS was detected in all tap water samples from Brazil. The highest level of PFASs contamination in a single sample was 140.48ng/l in a sample of Spanish tap water. In turn, in bottled waters the highest levels were detected in a French sample with 116ng/l as the sum of PFASs. Furthermore, the most frequent compounds and those at higher concentrations were perfluoroheptanoic acid (PFHpA) with a mean of frequencies in the three countries of 51.3%, followed by perfluorobutanesulfonic acid (PFBS) (27.2%) and perfluorooctanoic acid (PFOA) (23.0%). Considering that bottled water is approximately 38% of the total intake, the total PFASs exposure through drinking water intake for an adult man was estimated to be 54.8, 58.0 and 75.6ng/person per day in Spain, France and Brazil, respectively. However, assuming that the water content in other beverages has at least the same levels of contamination as in bottled drinking water, these amounts were increased to 72.2, 91.4 and 121.0ng/person per day for an adult man in Spain, France and Brazil, respectively. The results of total daily intake in different gender/age groups showed that children are the most exposed population group through hydration with maximum values in Brazil of 2.35 and 2.01ng/kg body weight (BW)/day for male and female, respectively. Finally, the RI was calculated. In spite of the highest values being found in Brazil, it was demonstrated that, in none of the investigated countries, drinking water pose imminent risk associated with PFASs contamination. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. 40 CFR 63.544 - Standards for process fugitive sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Smelting furnace and dryer charging hoppers, chutes, and skip hoists; (2) Smelting furnace lead taps, and molds during tapping; (3) Smelting furnace slag taps, and molds during tapping; (4) Refining kettles; (5) Dryer transition pieces; and (6) Agglomerating furnace product taps. (b) Process fugitive emission...

  13. Antenatal management of twin-twin transfusion syndrome and twin anemia-polycythemia sequence.

    PubMed

    Slaghekke, Femke; Zhao, Depeng P; Middeldorp, Johanna M; Klumper, Frans J; Haak, Monique C; Oepkes, Dick; Lopriore, Enrico

    2016-08-01

    Twin-twin transfusion syndrome (TTTS) and twin anemia polycythemia sequence (TAPS) are severe complications in monochorionic twin pregnancies associated with high mortality and morbidity risk if left untreated. Both diseases result from imbalanced inter-twin blood transfusion through placental vascular anastomoses. This review focuses on the differences in antenatal management between TTTS and TAPS. Expert commentary: The optimal management for TTTS is fetoscopic laser coagulation of the vascular anastomoses, preferably using the Solomon technique in which the whole vascular equator is coagulated. The Solomon technique is associated with a reduction of residual anastomosis and a reduction in post-operative complications. The optimal management for TAPS is not clear and includes expectant management, intra-uterine transfusion with or without partial exchange transfusion and fetoscopic laser surgery.

  14. Exposure to Tobacco Advertising and Promotion among School Children Aged 13-15 in Vietnam - an Overview from GYTS 2014.

    PubMed

    Long, Tran Khanh; Son, Phung Xuan; Giang, Kim Bao; Hai, Phan Thi; Huyen, Doan Thi Thu; Khue, Luong Ngoc; Nga, Pham Thi Quynh; Lam, Nguyen Tuan; Minh, Hoang Van; Huong, Le Thi Thanh

    2016-01-01

    Evidence shows that tobacco advertising and promotion activities may increase tobacco consumption and usage, especially in youth. Despite the regulation on prohibiting advertisement of any tobacco product, tobacco advertisement and promotion activities are still common in Vietnam. This article presents current exposure to tobacco advertising and promotion (TAP) among school children aged 13 to 15 years in Vietnam in 2014 and potential influencing factors. Data from the Global Youth Tobacco Survey 2014 in Vietnam covering 3,430 school aged children were used. Both descriptive and analytical statistics were carried out with Stata 13 statistical software. Binary logistic regression was applied to explain the exposure to TAP among youth and examine relationships with individual factors. A significance level of p<0.05 and sampling weights were used in all of the computations. In the past 30 days, 48.6% of the students experienced exposure to at least 1 type of tobacco advertising or promotion. Wearing or otherwise using products related to tobacco was the most exposure TAP type reported by students (22.3%). The internet (22.1), points of sales (19.2) and social events (11.5) were three places that students aged 13-15 frequently were exposed to TAP. Binary logistic results showed that gender (female vs male) (OR = 0.61, 95%CI: 0.52 - 0.71), susceptibility to smoking (OR = 2.12, 95%CI: 1.53 - 2.92), closest friends' smoked (OR = 1.43, 95%CI: 1.2 - 1.7) and parents smoking status (OR = 2.83, 95%CI: 1.6 - 5.01) were significantly associated with TAP exposure among school-aged children. The research findings should contribute to effective implementation of measures for preventing and controlling tobacco use among students aged 13-15 in Viet Nam.

  15. Evaluation of potential human health risk and investigation of drinking water quality in Isparta city center (Turkey).

    PubMed

    Varol, Simge; Davraz, Aysen

    2016-06-01

    Isparta city center is selected as a work area in this study because the public believes that the tap water is dirty and harmful. In this study, the city's drinking water in the distribution system and other spring waters which are used as drinking water in this region were investigated from the point of water quality and health risk assessment. Water samples were collected from major drinking water springs, tap waters, treatment plants and dam pond in the Isparta province center. Ca-Mg-HCO3, Mg-Ca-HCO3, Ca-Na-HCO3, Ca-HCO3, Ca-HCO3-SO4 and Ca-Mg-HCO3-SO4 are dominant water types. When compared to drinking water guidelines established by World Health Organization and Turkey, much greater attention should be paid to As, Br, Fe, F, NH4, PO4 through varied chemicals above the critical values. The increases of As, Fe, F, NH4 and PO4 are related to water-rock interaction. In tap waters, the increases of As and Fe are due to corrosion of pipes in drinking water distribution systems. The major toxic and carcinogenic chemicals within drinking water are As and Br for both tap water and spring water. Also, F is the non-carcinogenic chemical for only spring waters in the study area.

  16. Residential tap water contamination following the Freedom Industries chemical spill: perceptions, water quality, and health impacts.

    PubMed

    Whelton, Andrew J; McMillan, LaKia; Connell, Matt; Kelley, Keven M; Gill, Jeff P; White, Kevin D; Gupta, Rahul; Dey, Rajarshi; Novy, Caroline

    2015-01-20

    During January 2014, an industrial solvent contaminated West Virginia’s Elk River and 15% of the state population’s tap water. A rapid in-home survey and water testing was conducted 2 weeks following the spill to understand resident perceptions, tap water chemical levels, and premise plumbing flushing effectiveness. Water odors were detected in all 10 homes sampled before and after premise plumbing flushing. Survey and medical data indicated flushing caused adverse health impacts. Bench-scale experiments and physiochemical property predictions showed flushing promoted chemical volatilization, and contaminants did not appreciably sorb into cross-linked polyethylene (PEX) pipe. Flushing reduced tap water 4-methylcyclohexanemethanol (4-MCHM) concentrations within some but not all homes. 4-MCHM was detected at unflushed (<10 to 420 μg/L) and flushed plumbing systems (<10 to 96 μg/L) and sometimes concentrations differed among faucets within each home. All waters contained less 4-MCHM than the 1000 μg/L Centers for Disease Control drinking water limit, but one home exceeded the 120 μg/L drinking water limit established by independent toxicologists. Nearly all households refused to resume water use activities after flushing because of water safety concerns. Science based flushing protocols should be developed to expedite recovery, minimize health impacts, and reduce concentrations in homes when future events occur.

  17. Accuracy, precision, and economic efficiency for three methods of thrips (Thysanoptera: Thripidae) population density assessment.

    PubMed

    Sutherland, Andrew M; Parrella, Michael P

    2011-08-01

    Western flower thrips, Frankliniella occidentalis (Pergande) (Thysanoptera: Thripidae), is a major horticultural pest and an important vector of plant viruses in many parts of the world. Methods for assessing thrips population density for pest management decision support are often inaccurate or imprecise due to thrips' positive thigmotaxis, small size, and naturally aggregated populations. Two established methods, flower tapping and an alcohol wash, were compared with a novel method, plant desiccation coupled with passive trapping, using accuracy, precision and economic efficiency as comparative variables. Observed accuracy was statistically similar and low (37.8-53.6%) for all three methods. Flower tapping was the least expensive method, in terms of person-hours, whereas the alcohol wash method was the most expensive. Precision, expressed by relative variation, depended on location within the greenhouse, location on greenhouse benches, and the sampling week, but it was generally highest for the flower tapping and desiccation methods. Economic efficiency, expressed by relative net precision, was highest for the flower tapping method and lowest for the alcohol wash method. Advantages and disadvantages are discussed for all three methods used. If relative density assessment methods such as these can all be assumed to accurately estimate a constant proportion of absolute density, then high precision becomes the methodological goal in terms of measuring insect population density, decision making for pest management, and pesticide efficacy assessments.

  18. The Effect of Different Boiling and Filtering Devices on the Concentration of Disinfection By-Products in Tap Water

    PubMed Central

    Carrasco-Turigas, Glòria; Villanueva, Cristina M.; Goñi, Fernando; Rantakokko, Panu; Nieuwenhuijsen, Mark J.

    2013-01-01

    Disinfection by-products (DBPs) are ubiquitous contaminants in tap drinking water with the potential to produce adverse health effects. Filtering and boiling tap water can lead to changes in the DBP concentrations and modify the exposure through ingestion. Changes in the concentration of 4 individual trihalomethanes (THM4) (chloroform (TCM), bromodichloromethane (BDCM), dibromochloromethane (DBCM), and bromoform (TBM)), MX, and bromate were tested when boiling and filtering high bromine-containing tap water from Barcelona. For filtering, we used a pitcher-type filter and a household reverse osmosis filter; for boiling, an electric kettle, a saucepan, and a microwave were used. Samples were taken before and after each treatment to determine the change in the DBP concentration. pH, conductivity, and free/total chlorine were also measured. A large decrease of THM4 (from 48% to 97%) and MX concentrations was observed for all experiments. Bromine-containing trihalomethanes were mostly eliminated when filtering while chloroform when boiling. There was a large decrease in the concentration of bromate with reverse osmosis, but there was a little effect in the other experiments. These findings suggest that the exposure to THM4 and MX through ingestion is reduced when using these household appliances, while the decrease of bromate is device dependent. This needs to be considered in the exposure assessment of the epidemiological studies. PMID:23476675

  19. Evaluation of pesticide residues of organochlorine in vegetables and fruits in Qatar: statistical analysis.

    PubMed

    Al-Shamary, Noora M; Al-Ghouti, Mohammad A; Al-Shaikh, Ismail; Al-Meer, Saeed H; Ahmad, Talaat A

    2016-03-01

    The study aimed to examine the residues of organochlorines pesticides (OCPs) in vegetables and fruits in Qatar. A total of 127 samples was studied. Ninety percent of the imported samples recorded residues above the maximum residue levels (MRLs). The most frequently detected OCP in the samples was heptachlor (found in 75 samples). In the comparisons between the washed and unwashed samples, no significant differences were observed (P > 0.05). However, the effect of washing process with tap water depended on the type of vegetables and fruits.

  20. Brain activity during bilateral rapid alternate finger tapping measured with magnetoencephalography

    NASA Astrophysics Data System (ADS)

    Fukuda, Hiroshi; Odagaki, Masato; Hiwaki, Osamu; Kodabashi, Atsushi; Fujimoto, Toshiro

    2009-04-01

    Using magnetoencephalography (MEG), brain regions involved in an alternate bimanual tapping task by index fingers triggered with spontaneous timing were investigated. The tapping mode in which both index fingers moved simultaneously was interlaced during the task. The groups of the alternate tapping (AL mode) and the simultaneous tapping (SI mode) were extracted from the successive alternating taps with a histogram of intervals between the right and left index fingers. MEG signals in each mode were averaged separately before and after the tapping initiation of the dominant index finger. The activities of the contralateral sensorimotor cortex before and after the tapping initiation in the AL mode were larger than that in the SI mode. The result indicates that the activity of the contralateral sensorimotor cortex depends on the degree of achievement in the difficult motor task such as the voluntary alternate tapping movements.

  1. Freely Chosen Index Finger Tapping Frequency Is Increased in Repeated Bouts of Tapping.

    PubMed

    Hansen, Ernst Albin; Ebbesen, Brian Duborg; Dalsgaard, Ane; Mora-Jensen, Mark Holten; Rasmussen, Jakob

    2015-01-01

    Healthy individuals (n = 40) performed index finger tapping at freely chosen frequency during repeated bouts and before and after near-maximal muscle action consisting of 3 intense flexions of the index finger metacarpal phalangeal joint. One experiment showed, unexpectedly, that a bout of tapping increased the tapping frequency in the subsequent bout. Thus, a cumulating increase of 8.2 ± 5.4% (p < .001) occurred across 4 bouts, which were all separated by 10 min rest periods. Follow-up experiments revealed that tapping frequency was still increased in consecutive bouts when rest periods were extended to 20 min. Besides, near-maximal muscle activation, followed by 5 min rest, did not affect the tapping frequency. In conclusion, freely chosen tapping frequency was increased in repeated bouts of tapping, which were separated by 10-20 min rest periods. The observed phenomenon is suggested to be termed repeated bout rate enhancement.

  2. π Berry phase and Zeeman splitting of Weyl semimetal TaP

    DOE PAGES

    Hu, J.; Liu, J. Y.; Graf, D.; ...

    2016-01-04

    Here, the recent breakthrough in the discovery of Weyl fermions in monopnictide semimetals provides opportunities to explore the exotic properties of relativistic fermions in condensed matter. The chiral anomaly-induced negative magnetoresistance and π Berry phase are two fundamental transport properties associated with the topological characteristics of Weyl semimetals. Since monopnictide semimetals are multiple-band systems, resolving clear Berry phase for each Fermi pocket remains a challenge. Here we report the determination of Berry phases of multiple Fermi pockets of Weyl semimetal TaP through high field quantum transport measurements. We show our TaP single crystal has the signatures of a Weyl state,more » including light effective quasiparticle masses, ultrahigh carrier mobility, as well as negative longitudinal magnetoresistance. Furthermore, we have generalized the Lifshitz-Kosevich formula for multiple-band Shubnikov-de Haas (SdH) oscillations and extracted the Berry phases of π for multiple Fermi pockets in TaP through the direct fits of the modified LK formula to the SdH oscillations. In high fields, we also probed signatures of Zeeman splitting, from which the Landé g-factor is extracted.« less

  3. Assessment of leg muscle activity using toe tapping in patients with Parkinson's disease: comparison of two types of toe tapping.

    PubMed

    Taniguchi, Seira; Peper, Ferdinand; Shimokawa, Tetsuya

    2018-05-01

    [Purpose] This study investigates two types of toe tapping, i.e., "closed," with both feet on the floor, and "open," in which the foot does not touch the ground, and evaluates their usefulness in combination with monitoring of muscle activity during toe tapping. [Subjects and Methods] The study enrolled 11 patients with Parkinson's disease (PD) and 9 controls (Controls). The tibialis anterior (TA) and gastrocnemius (GS) muscle activity during toe tapping was measured using surface electromyography. [Results] In closed tapping, the minima in GS activation with the first tap was significantly higher in patients with PD than in Controls. In open tapping, the coefficient of variation (CV) of local maxima in TA activation was significantly higher in patients with PD than in Controls. In both types of tapping, the CV of extrema in GS activities increased with disease duration, but this may be due to the long-term administration of Levodopa, which itself tends to cause excessive GS activities. [Conclusion] Closed tapping is suitable for the assessment of GS activity and can detect excessive activities, which is observed as visible movement. Open tapping, on the other hand, is suitable for assessment of TA activity.

  4. Molecular mechanism and species specificity of TAP inhibition by herpes simplex virus ICP47.

    PubMed Central

    Ahn, K; Meyer, T H; Uebel, S; Sempé, P; Djaballah, H; Yang, Y; Peterson, P A; Früh, K; Tampé, R

    1996-01-01

    The immediate early protein ICP47 of herpes simplex virus (HSV) inhibits the transporter for antigen processing (TAP)-mediated translocation of antigen-derived peptides across the endoplasmic reticulum (ER) membrane. This interference prevents assembly of peptides with class I MHC molecules in the ER and ultimately recognition of HSV-infected cells by cytotoxic T-lymphocytes, potentially leading to immune evasion of the virus. Here, we demonstrate that recombinant, purified ICP47 containing a hexahistidine tag inhibits peptide import into microsomes of insect cells expressing human TAP, whereas inhibition of peptide transport by murine TAP was much less effective. This finding indicates an intrinsic species-specificity of ICP47 and suggests that no additional proteins interacting specifically with either ICP47 or TAP are required for inhibition of peptide transport. Since neither purified nor induced ICP47 inhibited photocrosslinking of 8-azido-ATP to TAP1 and TAP2 it seems that ICP47 does not prevent ATP from binding to TAP. By contrast, peptide binding was completely blocked by ICP47 as shown both by photoaffinity crosslinking of peptides to TAP and peptide binding to microsomes from TAP-transfected insect cells. Competition experiments indicated that ICP47 binds to human TAP with a higher affinity (50 nM) than peptides whereas the affinity to murine TAP was 100-fold lower. Our data suggest that ICP47 prevents peptides from being translocated by blocking their binding to the substrate-binding site of TAP. Images PMID:8670825

  5. Impact of Plumbing Age on Copper Levels in Drinking Water

    EPA Science Inventory

    Theory and limited practical experiences suggest that higher copper levels in drinking water tap samples are typically associated with newer plumbing systems, and levels decrease with increasing plumbing age. Past researchers have developed a conceptual model to explain the “agin...

  6. Assessing Environmental Stewardship Motivation

    ERIC Educational Resources Information Center

    Bramston, Paul; Pretty, Grace; Zammit, Charlie

    2011-01-01

    Environmental stewardship networks flourish across Australia. Although the environment benefits, this article looks to identify what volunteers draw from their stewardship. The authors adapted 16 questions that purportedly tap environmental stewardship motivation and administered them to a convenience sample of 318 university students and then to…

  7. Lead and Copper Rule Tier Schedule

    EPA Pesticide Factsheets

    The Lead and Copper Rule Tier Schedule may be used by public water systems in Wyoming and on EPA R8 Tribal Lands as a guide to properly identify their lead and copper tap sample sites to comply with the Lead and Copper Rule.

  8. Overexpression of the PP2A regulatory subunit Tap46 leads to enhanced plant growth through stimulation of the TOR signalling pathway

    PubMed Central

    Ahn, Chang Sook; Ahn, Hee-Kyung; Pai, Hyun-Sook

    2015-01-01

    Tap46, a regulatory subunit of protein phosphatase 2A (PP2A), plays an essential role in plant growth and development through a functional link with the Target of Rapamycin (TOR) signalling pathway. Here, we have characterized the molecular mechanisms behind a gain-of-function phenotype of Tap46 and its relationship with TOR to gain further insights into Tap46 function in plants. Constitutive overexpression of Tap46 in Arabidopsis resulted in overall growth stimulation with enlarged organs, such as leaves and siliques. Kinematic analysis of leaf growth revealed that increased cell size was mainly responsible for the leaf enlargement. Tap46 overexpression also enhanced seed size and viability under accelerated ageing conditions. Enhanced plant growth was also observed in dexamethasone (DEX)-inducible Tap46 overexpression Arabidopsis lines, accompanied by increased cellular activities of nitrate-assimilating enzymes. DEX-induced Tap46 overexpression and Tap46 RNAi resulted in increased and decreased phosphorylation of S6 kinase (S6K), respectively, which is a sensitive indicator of endogenous TOR activity, and Tap46 interacted with S6K in planta based on bimolecular fluorescence complementation and co-immunoprecipitation. Furthermore, inactivation of TOR by estradiol-inducible RNAi or rapamycin treatment decreased Tap46 protein levels, but increased PP2A catalytic subunit levels. Real-time quantitative PCR analysis revealed that Tap46 overexpression induced transcriptional modulation of genes involved in nitrogen metabolism, ribosome biogenesis, and lignin biosynthesis. These findings suggest that Tap46 modulates plant growth as a positive effector of the TOR signalling pathway and Tap46/PP2Ac protein abundance is regulated by TOR activity. PMID:25399018

  9. Evaluation of various soil water samplers for virological sampling.

    PubMed Central

    Wang, D S; Lance, J C; Gerba, C P

    1980-01-01

    Two commercially available soil water samplers and a ceramic sampler constructed in our laboratories were evaluated for their ability to recover viruses from both tap water and secondary sewage effluent. The ceramic sampler consistently gave the best recoveries of viruses from water samples. Soil columns containing ceramic samplers at various depths provide a simple method for studying virus transport through sewage-contaminated soils. Images PMID:6247976

  10. Enumeration of Somatic and F-RNA Phages as an Indicator of Fecal Contamination in Potable Water from Rural Areas of the North West Province.

    PubMed

    Nkwe, Keitumetse Idah; Ateba, Collins Njie; Sithebe, Nomathamsanqa Patricia; Bezuidenhout, Cornelius Carlos

    2015-07-01

    Bacteriophages are regarded as enteric viral indicators in faecally contaminated water systems and may indicate the presence of human viral pollution. They are relatively resistant to inactivation by natural and treatment processes. In this study, the presence of somatic coliphages and F-RNA coliphages was investigated in potable water from rural areas in the North West province. Water samples were aseptically collected from boreholes and tap water from some rural communities in the North West Province. Physical parameters of the water, such as the temperature, pH and turbidity, were measured before sample collection. Double-agar layer assay was performed using ISO, (1995, 2000) standard methods. Bottled water was used as a negative control and the strains фX174 and MS2 as positive controls. Of the 16 water samples collected, 15 were positive for somatic bacteriophages while F-RNA coliphages were detected in only two samples. Amongst the positive samples 189 and three plaque forming units were obtained for both somatic and F-RNA coliphages, respectively. No coliphage was detected in water from Masamane tap 1. The rest of the samples obtained from various rural areas were positive and did not comply with national and international standards for potable water. This was a cause for concern and should be further investigated.

  11. Enumeration of Somatic and F-RNA Phages as an Indicator of Fecal Contamination in Potable Water from Rural Areas of the North West Province

    PubMed Central

    Nkwe, Keitumetse Idah; Ateba, Collins Njie; Sithebe, Nomathamsanqa Patricia; Bezuidenhout, Cornelius Carlos

    2015-01-01

    Bacteriophages are regarded as enteric viral indicators in faecally contaminated water systems and may indicate the presence of human viral pollution. They are relatively resistant to inactivation by natural and treatment processes. In this study, the presence of somatic coliphages and F-RNA coliphages was investigated in potable water from rural areas in the North West province. Water samples were aseptically collected from boreholes and tap water from some rural communities in the North West Province. Physical parameters of the water, such as the temperature, pH and turbidity, were measured before sample collection. Double-agar layer assay was performed using ISO, (1995, 2000) standard methods. Bottled water was used as a negative control and the strains фX174 and MS2 as positive controls. Of the 16 water samples collected, 15 were positive for somatic bacteriophages while F-RNA coliphages were detected in only two samples. Amongst the positive samples 189 and three plaque forming units were obtained for both somatic and F-RNA coliphages, respectively. No coliphage was detected in water from Masamane tap 1. The rest of the samples obtained from various rural areas were positive and did not comply with national and international standards for potable water. This was a cause for concern and should be further investigated. PMID:26140675

  12. Synergistic cooperation of MDM2 and E2F1 contributes to TAp73 transcriptional activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kasim, Vivi, E-mail: vivikasim78@gmail.com; Huang, Can; Zhang, Jing

    2014-07-04

    Highlights: • MDM2 is a novel positive regulator of TAp73 transcriptional activity. • MDM2 colocalizes together and physically interacts with E2F1. • Synergistic cooperation of MDM2 and E2F1 is crucial for TAp73 transcription. • MDM2 regulates TAp73 transcriptional activity in a p53-independent manner. - Abstract: TAp73, a structural homologue of p53, plays an important role in tumorigenesis. E2F1 had been reported as a transcriptional regulator of TAp73, however, the detailed mechanism remains to be elucidated. Here we reported that MDM2-silencing reduced the activities of the TAp73 promoters and the endogenous TAp73 expression level significantly; while MDM2 overexpression upregulated them. Wemore » further revealed that the regulation of TAp73 transcriptional activity occurs as a synergistic effect of MDM2 and E2F1, most probably through their physical interaction in the nuclei. Furthermore, we also suggested that MDM2 might be involved in DNA damage-induced TAp73 transcriptional activity. Finally, we elucidated that MDM2-silencing reduced the proliferation rate of colon carcinoma cells regardless of the p53 status. Our data show a synergistic effect of MDM2 and E2F1 on TAp73 transcriptional activity, suggesting a novel regulation pathway of TAp73.« less

  13. A randomized trial comparing surgeon-administered intraoperative transversus abdominis plane block with anesthesiologist-administered transcutaneous block.

    PubMed

    Narasimhulu, D M; Scharfman, L; Minkoff, H; George, B; Homel, P; Tyagaraj, K

    2018-04-27

    Injection of local anesthetic into the transversus abdominis plane (TAP block) decreases systemic morphine requirements after abdominal surgery. We compared intraoperative surgeon-administered TAP block (surgical TAP) to anesthesiologist-administered transcutaneous ultrasound-guided TAP block (conventional TAP) for post-cesarean analgesia. We hypothesized that surgical TAP blocks would take less time to perform than conventional TAP blocks. We performed a randomized trial, recruiting 41 women undergoing cesarean delivery under neuraxial anesthesia, assigning them to either surgical TAP block (n=20) or conventional TAP block (n=21). Time taken to perform the block was the primary outcome, while postoperative pain scores and 24-hour opioid requirements were secondary outcomes. Student's t-test was used to compare block time and Kruskal-Wallis test opioid consumption and pain-scores. Time taken to perform the block (2.4 vs 12.1 min, P <0.001), and time spent in the operating room after delivery (55.3 vs 77.9 min, P <0.001) were significantly less for surgical TAP. The 24 h morphine consumption (P=0.17) and postoperative pain scores at 4, 8, 24 and 48 h were not significantly different between the groups. Surgical TAP blocks are feasible and less time consuming than conventional TAP blocks, while providing comparable analgesia after cesarean delivery. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Worldwide drinking water occurrence and levels of newly-identified perfluoroalkyl and polyfluoroalkyl substances.

    PubMed

    Kaboré, Hermann A; Vo Duy, Sung; Munoz, Gabriel; Méité, Ladji; Desrosiers, Mélanie; Liu, Jinxia; Sory, Traoré Karim; Sauvé, Sébastien

    2018-03-01

    In the last decade or so, concerns have arisen with respect to the widespread occurrence of perfluoroalkyl acids (PFAAs) in the environment, food, drinking water, and humans. In this study, the occurrence and levels of a large range of perfluoroalkyl and polyfluoroalkyl substances (PFASs) were investigated in drinking water (bottled and tap water samples) from various locations around the world. Automated off-line solid phase extraction followed by ultra-high-performance liquid chromatography coupled to high-resolution mass spectrometry was used to analyze PFASs of various chain lengths and functional groups. In total, 29 target and 104 suspect-target PFASs were screened in drinking water samples (n=97) from Canada and other countries (Burkina Faso, Chile, Ivory Coast, France, Japan, Mexico, Norway, and the USA) in 2015-2016. Out of the 29 PFASs quantitatively analyzed, perfluorocarboxylates (PFCAs: C 4/14 ), perfluoroalkane sulfonates (PFSAs: C 4 , C 6 , C 8 ), and perfluoroalkyl acid precursors (e.g., 5:3 fluorotelomer carboxylate (5:3 FTCA)) were recurrently detected in drinking water samples (concentration range:

  15. Risk characterization of methyl tertiary butyl ether (MTBE) in tap water.

    PubMed

    Stern, B R; Tardiff, R G

    1997-12-01

    Methyl tertiary butyl ether (MTBE) can enter surface water and groundwater through wet atmospheric deposition or as a result of fuel leaks and spills. About 30% of the U.S. population lives in areas where MTBE is in regular use. Ninety-five percent of this population is unlikely to be exposed to MTBE in tap water at concentrations exceeding 2 ppb, and most will be exposed to concentrations that are much lower and may be zero. About 5% of this population may be exposed to higher levels of MTBE in tap water, resulting from fuel tank leaks and spills into surface or groundwater used for potable water supplies. This paper describes the concentration ranges found and anticipated in surface and groundwater, and estimates the distribution of doses experienced by humans using water containing MTBE to drink, prepare food, and shower/bathe. The toxic properties (including potency) of MTBE when ingested, inhaled, and in contact with the skin are summarized. Using a range of human toxic potency values derived from animal studies, margins of exposure (MOE) associated with alternative chronic exposure scenarios are estimated to range from 1700 to 140,000. Maximum concentrations of MTBE in tap water anticipated not to cause adverse health effects are determined to range from 700 to 14,000 ppb. The results of this analysis demonstrate that no health risks are likely to be associated with chronic and subchronic human exposures to MTBE in tap water. Although some individuals may be exposed to very high concentrations of MTBE in tap water immediately following a localized spill, these exposures are likely to be brief in duration due to large-scale dilution and rapid volatilization of MTBE, the institution of emergency response and remediation measures to minimize human exposures, and the low taste and odor thresholds of MTBE which ensure that its presence in tap water is readily detected at concentrations well below the threshold for human injury.

  16. Plasma-activation of tap water using DBD for agronomy applications: Identification and quantification of long lifetime chemical species and production/consumption mechanisms.

    PubMed

    Judée, F; Simon, S; Bailly, C; Dufour, T

    2018-04-15

    Cold atmospheric plasmas are weakly ionized gases that can be generated in ambient air. They produce energetic species (e.g. electrons, metastables) as well as reactive oxygen species, reactive nitrogen species, UV radiations and local electric field. Their interaction with a liquid such as tap water can hence change its chemical composition. The resulting "plasma-activated liquid" can meet many applications, including medicine and agriculture. Consequently, a complete experimental set of analytical techniques dedicated to the characterization of long lifetime chemical species has been implemented to characterize tap water treated using cold atmospheric plasma process and intended to agronomy applications. For that purpose, colorimetry and acid titrations are performed, considering acid-base equilibria, pH and temperature variations induced during plasma activation. 16 species are quantified and monitored: hydroxide and hydronium ions, ammonia and ammonium ions, orthophosphates, carbonate ions, nitrite and nitrate ions and hydrogen peroxide. The related consumption/production mechanisms are discussed. In parallel, a chemical model of electrical conductivity based on Kohlrausch's law has been developed to simulate the electrical conductivity of the plasma-activated tap water (PATW). Comparing its predictions with experimental measurements leads to a narrow fitting, hence supporting the self-sufficiency of the experimental set, I.e. the fact that all long lifetime radicals of interest present in PATW are characterized. Finally, to evaluate the potential of cold atmospheric plasmas for agriculture applications, tap water has been daily plasma-treated to irrigate lentils seeds. Then, seedlings lengths have been measured and compared with untreated tap water, showing an increase as high as 34.0% and 128.4% after 3 days and 6 days of activation respectively. The interaction mechanisms between plasma and tap water are discussed as well as their positive synergy on agronomic results. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. The Cutaneous Rabbit Revisited

    ERIC Educational Resources Information Center

    Flach, Rudiger; Haggard, Patrick

    2006-01-01

    In the cutaneous rabbit effect (CRE), a tactile event (so-called attractee tap) is mislocalized toward an adjacent attractor tap. The effect depends on the time interval between the taps. The authors delivered sequences of taps to the forearm and asked participants to report the location of one of the taps. The authors replicated the original CRE…

  18. Genotoxicity and cytotoxicity assessment in lake drinking water produced in a treatment plant.

    PubMed

    Buschini, Annamaria; Carboni, Pamela; Frigerio, Silvia; Furlini, Mariangela; Marabini, Laura; Monarca, Silvano; Poli, Paola; Radice, Sonia; Rossi, Carlo

    2004-09-01

    Chemical analyses and short-term mutagenicity bioassays have revealed the presence of genotoxic disinfection by-products in drinking water. In this study, the influence of the different steps of surface water treatment on drinking water mutagen content was evaluated. Four different samples were collected at a full-scale treatment plant: raw lake water (A), water after pre-disinfection with chlorine dioxide and coagulation (B), water after pre-disinfection, coagulation and granular activated carbon filtration (C) and tap water after post-disinfection with chlorine dioxide just before its distribution (D). Water samples, concentrated by solid phase adsorption on silica C18 columns, were tested in human leukocytes and HepG2 hepatoma cells using the comet assay and in HepG2 cells in the micronuclei test. A significant increase in DNA migration was observed in both cell types after 1 h treatment with filtered and tap water, and, to a lesser extent, chlorine dioxide pre-disinfected water. Similar findings were observed for the induction of "ghost" cells. Overloading of the carbon filter, with a consequent peak release, might explain the high genotoxicity found in water samples C and D. Cell toxicity and DNA damage increases were also detected in metabolically competent HepG2 cells treated with a lower concentration of tap water extract for a longer exposure time (24 h). None of the water extracts significantly increased micronuclei frequencies. Our monitoring approach appears to be able to detect contamination related to the different treatment stages before drinking water consumption and the results suggest the importance of improving the technologies for drinking water treatment to prevent human exposure to potential genotoxic compounds.

  19. Energy Conservation and the Promotion of Legionella pneumophila Growth: The Probable Role of Heat Exchangers in a Nosocomial Outbreak.

    PubMed

    Bédard, Emilie; Lévesque, Simon; Martin, Philippe; Pinsonneault, Linda; Paranjape, Kiran; Lalancette, Cindy; Dolcé, Charles-Éric; Villion, Manuela; Valiquette, Louis; Faucher, Sébastien P; Prévost, Michèle

    2016-12-01

    OBJECTIVE To determine the source of a Legionella pneumophila serogroup 5 nosocomial outbreak and the role of the heat exchanger installed on the hot water system within the previous year. SETTING A 400-bed tertiary care university hospital in Sherbrooke, Canada. METHODS Hot water samples were collected and cultured for L. pneumophila from 25 taps (baths and sinks) within wing A and 9 taps in wing B. Biofilm (5) and 2 L water samples (3) were collected within the heat exchangers for L. pneumophila culture and detection of protists. Sequence-based typing was performed on strain DNA extracts and pulsed-field gel electrophoresis patterns were analyzed. RESULTS Following 2 cases of hospital-acquired legionellosis, the hot water system investigation revealed a large proportion of L. pneumophila serogroup 5 positive taps (22/25 in wing A and 5/9 in wing B). High positivity was also detected in the heat exchanger of wing A in water samples (3/3) and swabs from the heat exchanger (4/5). The outbreak genotyping investigation identified the hot water system as the source of infections. Genotyping results revealed that all isolated environmental strains harbored the same related pulsed-field gel electrophoresis pattern and sequence-based type. CONCLUSIONS Two cases of hospital-acquired legionellosis occurred in the year following the installation of a heat exchanger to preheat hospital hot water. No cases were reported previously, although the same L. pneumophila strain was isolated from the hot water system in 1995. The heat exchanger promoted L. pneumophila growth and may have contributed to confirmed clinical cases. Infect. Control Hosp. Epidemiol. 2016;1475-1480.

  20. Gravid Anopheles gambiae sensu stricto avoid ovipositing in Bermuda grass hay infusion and it's volatiles in two choice egg-count bioassays.

    PubMed

    Eneh, Lynda K; Okal, Michael N; Borg-Karlson, Anna-Karin; Fillinger, Ulrike; Lindh, Jenny M

    2016-05-12

    A number of mosquito species in the Culex and Aedes genera prefer to lay eggs in Bermuda grass (Cynodon dactylon) hay infusions compared to water alone. These mosquitoes are attracted to volatile compounds from the hay infusions making the infusions effective baits in gravid traps used for monitoring vectors of arboviral and filarial pathogens. Since Bermuda grass is abundant and widespread, it is plausible to explore infusions made from it as a potential low cost bait for outdoor monitoring of the elusive malaria vector Anopheles gambiae s.s. This study investigated preferential egg laying of individual An. gambiae s.s. in hay infusion or in tap water treated with volatiles detected in hay infusion headspace compared to tap water alone, using two-choice egg-count bioassays. Infusions were prepared by mixing 90 g of dried Bermuda grass (hay) with 24 L of unchlorinated tap water in a bucket, and leaving it for 3 days at ambient temperature and humidity. The volatiles in the headspace of the hay infusion were sampled with Tenax TA traps for 20 h and analysed using gas chromatography coupled to mass spectrometry. In total, 18 volatiles were detected in the infusion headspace. Nine of the detected compounds and nonanal were selected for bioassays. Eight of the selected compounds have previously been suggested to attract/stimulate egg laying in An. gambiae s.s. Gravid females were significantly (p < 0.05) less likely to lay eggs in hay infusion dilutions of 25, 50 and 100 % and in tap water containing any of six compounds (3-methylbutanol, phenol, 4-methylphenol, nonanal, indole, and 3-methylindole) compared to tap water alone. The oviposition response to 10 % hay infusion or any one of the remaining four volatiles (4-hepten-1-ol, phenylmethanol, 2-phenylethanol, or 4-ethylphenol) did not differ from that in tap water. Anopheles gambiae s.s. prefers to lay eggs in tap water rather than Bermuda grass hay infusion. This avoidance of the hay infusion appears to be mediated by volatile organic compounds from the infusion. It is, therefore, unlikely that Bermuda grass hay infusion as formulated and used in gravid traps for Culex and Aedes mosquitoes will be suitable baits for monitoring gravid An. gambiae s.s.

  1. Ultrasound-guided Combined Fascial Plane Blocks as an Intervention for Pain Management after Laparoscopic Cholecystectomy: A Randomized Control Study

    PubMed Central

    Ramkiran, Seshadri; Jacob, Mathews; Honwad, Manish; Vivekanand, Desiraju; Krishnakumar, Mathangi; Patrikar, Seema

    2018-01-01

    Background: Pain associated with laparoscopic cholecystectomy is most severe during the first 24 h and the port sites are the most painful. Recent multimodal approaches target incisional pain instead of visceral pain which has led to the emergence of abdominal fascial plane blocks. This study embraces a novel combination of two independently effective fascial plane blocks, namely rectus sheath block and subcostal transversus abdominis plane (TAP) block to alleviate postoperative pain. Study Objective: The aim is to evaluate the effectiveness of the combination of rectus sheath block and subcostal TAP block, to compare its efficacy with that of subcostal TAP block alone and with conventional port site infiltration (PSI) in alleviating postoperative pain in patients undergoing laparoscopic cholecystectomy. Methodology: This prospective, randomized control, pilot study included 61 patients scheduled for elective laparoscopic cholecystectomy and distributed among three groups, namely Group 1: Combined subcostal TAP block with rectus sheath block (n = 20); Group 2: Oblique subcostal TAP block alone (n = 21); and Group 3: PSI group as an active control (n = 20). Results: Combined group had significantly lower pain scores, higher satisfaction scores, and reduced rescue analgesia both in early and late postoperative periods than the conventional PSI group. Conclusion: Ultrasound-guided combined fascial plane blocks is a novel intervention in pain management of patients undergoing laparoscopic cholecystectomy and should become the standard of care. PMID:29628547

  2. Tapping-mode AFM study of tip-induced polymer deformation under geometrical confinement.

    PubMed

    Zhang, Hong; Honda, Yukio; Takeoka, Shinji

    2013-02-05

    The morphological stability of polymer films is critically important to their application as functional materials. The deformation of polymer surfaces on the nanoscale may be significantly influenced by geometrical confinement. Herein, we constructed a mechanically heterogeneous polymer surface by phase separation in a thin polymer film and investigated the deformation behavior of its nanostructure (∼30 nm thickness and ∼100 nm average diameter) with tapping-mode atomic force microscopy. By changing different scan parameters, we could induce deformation localized to the nanostructure in a controllable manner. A quantity called the deformation index is defined and shown to be correlated to energy dissipation by tip-sample interaction. We clarified that the plastic deformation of a polymer on the nanoscale is energy-dependent and is related to the glass-to-rubber transition. The mobility of polymer chains beneath the tapping tip is enhanced, and in the corresponding region a rubberlike deformation with the lateral motion of the tip is performed. The method we developed can provide insight into the geometrical confinement effects on polymer behavior.

  3. The influence of the insertion technique on the pullout force of pedicle screws: an experimental study.

    PubMed

    Chatzistergos, Panagiotis E; Sapkas, George; Kourkoulis, Stavros K

    2010-04-20

    The pullout strength of a typical pedicle screw was evaluated experimentally for different screw insertion techniques. OBJECTIVE.: To conclude whether the self-tapping insertion technique is indeed the optimum one for self-tapping screws, with respect to the pullout strength. It is reported in the literature that the size of the pilot-hole significantly influences the pullout strength of a self-tapping screw. In addition it is accepted that an optimum value of the diameter of the pilot-hole exists. For non self-tapping screw insertion it is reported that undertapping of the pilot-hole can increase its pullout strength. Finally it is known that in some cases orthopedic surgeons open the threaded holes, using another screw instead of a tap. A typical commercial self-tapping pedicle screw was inserted into blocks of Solid Rigid Polyurethane Foam (simulating osteoporotic cancellous bone), following different insertion techniques. The pullout force was measured according to the ASTM-F543-02 standard. The screw was inserted into previously prepared holes of different sizes, either threaded or cylindrical, to conclude whether an optimum size of the pilot-hole exists and whether tapping can increase the pullout strength. The case where the tapping is performed using another screw was also studied. For screw insertion with tapping, decreasing the outer radius of the threaded hole from 1.00 to 0.87 of the screw's outer radius increased the pullout force 9%. For insertion without tapping, decreasing the pilot-hole's diameter from 0.87 to 0.47 of the screw's outer diameter increased its pullout force 75%. Finally, tapping using another screw instead of a tap, gave results similar to those of conventional tapping. Undertapping of a pilot-hole either using a tap or another screw can increase the pullout strength of self-tapping pedicle screws.

  4. Temporal prediction abilities are mediated by motor effector and rhythmic expertise.

    PubMed

    Manning, Fiona C; Harris, Jennifer; Schutz, Michael

    2017-03-01

    Motor synchronization is a critical part of musical performance and listening. Recently, motor control research has described how movements that contain more available degrees of freedom are more accurately timed. Previously, we demonstrated that stick tapping improves perception in a timing detection task, where percussionists greatly outperformed non-percussionists only when tapping along. Since most synchronization studies implement finger tapping to examine simple motor synchronization, here we completed a similar task where percussionists and non-percussionists synchronized using finger tapping; movement with fewer degrees of freedom than stick tapping. Percussionists and non-percussionists listened to an isochronous beat sequence and identified the timing of a probe tone. On half of the trials, they tapped along with their index finger, and on the other half of the trials, they listened without moving prior to making timing judgments. We found that both groups benefited from tapping overall. Interestingly, percussionists performed only marginally better than did non-percussionists when finger tapping and no different when listening alone, differing from past studies reporting highly superior timing abilities in percussionists. Additionally, we found that percussionist finger tapping was less variable and less asynchronous than was non-percussionist tapping. Moreover, in both groups finger tapping was more variable and more asynchronous than stick tapping in our previous study. This study demonstrates that the motor effector implemented in tapping studies affects not only synchronization abilities, but also subsequent prediction abilities. We discuss these findings in light of effector-specific training and degrees of freedom in motor timing, both of which impact timing abilities to different extents.

  5. PREDICTIVE MODELING OF ACOUSTIC SIGNALS FROM THERMOACOUSTIC POWER SENSORS (TAPS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dumm, Christopher M.; Vipperman, Jeffrey S.

    2016-06-30

    Thermoacoustic Power Sensor (TAPS) technology offers the potential for self-powered, wireless measurement of nuclear reactor core operating conditions. TAPS are based on thermoacoustic engines, which harness thermal energy from fission reactions to generate acoustic waves by virtue of gas motion through a porous stack of thermally nonconductive material. TAPS can be placed in the core, where they generate acoustic waves whose frequency and amplitude are proportional to the local temperature and radiation flux, respectively. TAPS acoustic signals are not measured directly at the TAPS; rather, they propagate wirelessly from an individual TAPS through the reactor, and ultimately to a low-powermore » receiver network on the vessel’s exterior. In order to rely on TAPS as primary instrumentation, reactor-specific models which account for geometric/acoustic complexities in the signal propagation environment must be used to predict the amplitude and frequency of TAPS signals at receiver locations. The reactor state may then be derived by comparing receiver signals to the reference levels established by predictive modeling. In this paper, we develop and experimentally benchmark a methodology for predictive modeling of the signals generated by a TAPS system, with the intent of subsequently extending these efforts to modeling of TAPS in a liquid sodium environmen« less

  6. Finding the right fit: studying the biomechanics of under-tapping with varying thread depths and pitches.

    PubMed

    Jazini, Ehsan; Petraglia, Carmen; Moldavsky, Mark; Tannous, Oliver; Weir, Tristan; Saifi, Comron; Elkassabany, Omar; Cai, Yiwei; Bucklen, Brandon; O'Brien, Joseph; Ludwig, Steven C

    2017-04-01

    Compromise of pedicle screw purchase is a concern in maintaining rigid spinal fixation, especially with osteoporosis. Little consistency exists among various tapping techniques. Pedicle screws are often prepared with taps of a smaller diameter, which can further exacerbate inconsistency. The objective of this study was to determine whether a mismatch between tap thread depth (D) and thread pitch (P) and screw D and P affects fixation when under-tapping in osteoporotic bone. This study is a polyurethane foam block biomechanical analysis. A foam block osteoporotic bone model was used to compare pullout strength of pedicle screws with a 5.3 nominal diameter tap of varying D's and P's. Blocks were sorted into seven groups: (1) probe only; (2) 0.5-mm D, 1.5-mm P tap; (3) 0.5-mm D, 2.0-mm P tap; (4) 0.75-mm D, 2.0-mm P tap; (5) 0.75-mm D, 2.5-mm P tap; (6) 0.75-mm D, 3.0-mm P tap; and (7) 1.0-mm D, 2.5-mm P tap. A pedicle screw, 6.5 mm in diameter and 40 mm in length, was inserted to a depth of 40 mm. Axial pullout testing was performed at a rate of 5 mm/min on 10 blocks from each group. No significant difference was noted between groups under axial pullout testing. The mode of failure in the probe-only group was block fracture, occurring in 50% of cases. Among the other six groups, only one screw failed because of block fracture. The other 59 failed because of screw pullout. In an osteoporotic bone model, changing the D or P of the tap has no statistically significant effect on axial pullout. Osteoporotic bone might render tap features marginal. Our findings indicate that changing the characteristics of the tap D and P does not help with pullout strength in an osteoporotic model. The high rate of fracture in the probe-only group might imply the potential benefit of tapping to prevent catastrophic failure of bone. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Effects of age, task, and frequency on variability of finger tapping.

    PubMed

    Sommervoll, Yngve; Ettema, Gertjan; Vereijken, Beatrix

    2011-10-01

    The goal was to assess whether prior studies might have overestimated performance variability in older adults in dual task conditions by relying on primary motor tasks that are not constant with aging. 30 younger and 31 older adults performed a bimanual tapping task at four different frequencies in isolation or concurrently with a secondary task. Results showed that performance of younger and older adults was not significantly different in performing the tapping task at all frequencies and with either secondary task, as indicated by mean tapping performance and low number of errors in the secondary tasks. Both groups showed increased variability as tapping frequency increased and with the presence of a secondary task. Tapping concurrently while reading words increased tapping variability more than tapping concurrently while naming colours. Although older participants' performances were overall more variable, no interaction effects with age were found and at the highest frequencies of tapping, younger and older participants did not differ in performance.

  8. Inactivation of Escherichia coli by titanium dioxide photocatalytic oxidation.

    EPA Science Inventory

    Titanium dioxide in the anatase crystalline form was used as a photocatalyst to generate hydroxyl radicals in a flowthrough water reactor. Experiments were performed on pure cultures of Escherichia coli in dechlorinated tap water and a surface water sample to evaluate the disinfe...

  9. A Measure for Evaluating the Effectiveness of Teen Pregnancy Prevention Programs.

    ERIC Educational Resources Information Center

    Somers, Cheryl L.; Johnson, Stephanie A.; Sawilowksy, Shlomo S.

    2002-01-01

    The Teen Attitude Pregnancy Scale (TAPS) was developed to measure teen attitudes and intentions regarding teenage pregnancy. The model demonstrated good internal consistency and concurrent validity for the samples in this study. Analysis revealed evidence of validity for this model. (JDM)

  10. [Survey on the contamination of microcystin-LR in water supply of Shanghai city].

    PubMed

    Wu, He-yan; Zheng, Li-xing; Su, Jin; Shi, Wei

    2005-03-01

    To study the pollution level of microcystin-LR in water supply of Shanghai city and the removal efficacy for microcystin-LR through routine water treatment technique. High performance liquid chromatogram (HPLC) was applied to determine the concentration of microcystin-LR in source water, water samples after various water treatment procedures and tap water. The concentration of microcystin-LR varied with sampling seasons and sites and reached peak during summer and fall. The maximum of microcystin-LR was 2.38 microg/L in source water. Coagulation plus chlorine disinfection were found to be effective for the removal of microcystin-LR, while the remove rate through filtration was not significant. And it could also be detected in tap water as high as 1.27 microg/L. The source waters of Shanghai city were polluted by cyanobacteria toxins represented by microcystin-LR. The source water in suburb was more polluted. Routine water treatment techniques can not remove the toxins effectively.

  11. A magnetic-based dispersive micro-solid-phase extraction method using the metal-organic framework HKUST-1 and ultra-high-performance liquid chromatography with fluorescence detection for determining polycyclic aromatic hydrocarbons in waters and fruit tea infusions.

    PubMed

    Rocío-Bautista, Priscilla; Pino, Verónica; Ayala, Juan H; Pasán, Jorge; Ruiz-Pérez, Catalina; Afonso, Ana M

    2016-03-04

    A hybrid material composed by the metal-organic framework (MOF) HKUST-1 and Fe3O4 magnetic nanoparticles (MNPs) has been synthetized in a quite simple manner, characterized, and used in a magnetic-assisted dispersive micro-solid-phase extraction (M-d-μSPE) method in combination with ultra-high-performance liquid chromatography (UHPLC) and fluorescence detection (FD). The application was devoted to the determination of 8 heavy polycyclic aromatic hydrocarbons (PAHs) in different aqueous samples, specifically tap water, wastewaters, and fruit tea infusion samples. The overall M-d-μSPE-UHPLC-FD method was optimized and validated. The method is characterized by: its simplicity in both the preparation of the hybrid material (simple mixing) and the magnetic-assisted approach (∼10min extraction time), the use of low sorbent amounts (20mg of HKUST-1 and 5mg of Fe3O4 MNPs), and the low organic solvent consumption in the overall M-d-μSPE-UHPLC-FD method (1.5mL of acetonitrile in the M-d-μSPE method and 2.8mL of acetonitrile in the UHPLC-FD run). The resulting method has high sensitivity, with LODs down to 0.8ngL(-1); adequate intermediate precision, with relative standard deviation values (RSD) always lower than 6.3% (being the range 5.9-9.0% in tap water for a spiked level of 45ngL(-1), 6.1-14% in wastewaters for a spiked level of 45ngL(-1), and 7.2-17% in fruit tea infusion samples for a spiked level of 45ngL(-1)); and adequate relative recoveries, with average values of 82% in tap water, and 94% and 75% in wastewater and fruit tea infusion samples, respectively, if using the proper matrix-matched calibration. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Sensors for Using Times of Flight to Measure Flow Velocities

    NASA Technical Reports Server (NTRS)

    Fralick, Gutave; Wrbanek, John D.; Hwang, Danny; Turso, James

    2006-01-01

    Thin-film sensors for measuring flow velocities in terms of times of flight are undergoing development. These sensors are very small and can be mounted flush with surfaces of airfoils, ducts, and other objects along which one might need to measure flows. Alternatively or in addition, these sensors can be mounted on small struts protruding from such surfaces for acquiring velocity measurements at various distances from the surfaces for the purpose of obtaining boundary-layer flow-velocity profiles. These sensors are related to, but not the same as, hot-wire anemometers. Each sensor includes a thin-film, electrically conductive loop, along which an electric current is made to flow to heat the loop to a temperature above that of the surrounding fluid. Instantaneous voltage fluctuations in segments of the loop are measured by means of electrical taps placed at intervals along the loop. These voltage fluctuations are caused by local fluctuations in electrical resistance that are, in turn, caused by local temperature fluctuations that are, in turn, caused by fluctuations in flow-induced cooling and, hence, in flow velocity. The differential voltage as a function of time, measured at each pair of taps, is subjected to cross-correlation processing with the corresponding quantities measured at other pairs of taps at different locations on the loop. The cross-correlations yield the times taken by elements of fluid to travel between the pairs of taps. Then the component of velocity along the line between any two pairs of taps is calculated simply as the distance between the pairs of taps divided by the travel time. Unlike in the case of hot-wire anemometers, there is no need to obtain calibration data on voltage fluctuations versus velocity fluctuations because, at least in principle, the correlation times are independent of the calibration data.

  13. Acute effects of a single warm-water bath on serum adiponectin and leptin levels in healthy men: A pilot study

    NASA Astrophysics Data System (ADS)

    Shimodozono, Megumi; Matsumoto, Shuji; Ninomiya, Koji; Miyata, Ryuji; Ogata, Atsuko; Etoh, Seiji; Watanabe, Satoshi; Kawahira, Kazumi

    2012-09-01

    To preliminarily assess the acute effects of a single warm -water bath (WWB) on serum adipokine activity, we measured serum adiponectin, leptin and other metabolic profiles before, immediately after and 30 minutes after WWB in seven healthy male volunteers (mean age, 39.7 ± 6.0 years; mean body mass index, 21.6 ± 1.8 kg/m2). The subjects were immersed in tap water at 41°C for 10 minutes. Two weeks later, the same subjects underwent a single WWB with a bath additive that included inorganic salts and carbon dioxide (WWB with ISCO2) by the same protocol as for the first WWB. Leptin levels significantly increased immediately after WWB with tap water and ISCO2 (both P < 0.05), and remained significantly higher than those at baseline even 30 minutes after WWB with tap water ( P < 0.05). Adiponectin levels showed a slight, but not significant, increase both immediately after and 30 minutes after WWB with tap water or ISCO2. Some parameters, such as serum total cholesterol, red blood cell count, hemoglobin and hematocrit significantly increased immediately after WWB with tap water or ISCO2 (all P < 0.05), but they all returned to the baseline levels 30 minutes after bathing under both conditions. The sublingual temperature rose significantly after 10 minutes of WWB with tap water (0.96 ± 0.16°C relative to baseline, P < 0.01) and after the same duration of WWB with ISCO2 (1.24 ± 0.34°C relative to baseline, P < 0.01). These findings suggest that a single WWB at 41°C for 10 minutes may modulate leptin and adiponectin profiles in healthy men.

  14. Ultrasound-guided rectus sheath and transversus abdominis plane blocks for perioperative analgesia in upper abdominal surgery: A randomized controlled study.

    PubMed

    Abdelsalam, Khaled; Mohamdin, O W

    2016-01-01

    Regional anesthetic techniques can be used to alleviate postoperative pain in patients undergoing major upper abdominal surgery. Our aim was to evaluate the efficacy of bilateral ultrasound (US)-guided rectus sheath (RS) and transversus abdominis plane (TAP) blocks for better perioperative analgesia. It is a prospective, observer-blinded, randomized clinical study. 40 eligible patients undergoing elective liver resection or Whipple procedure were included. All patients received a standardized anesthetic technique. Group 1 (n = 20) received preincisional US-guided bilateral RS and TAP blocks using 20 ml volume of bupivacaine 0.25% for each, and group 2 (n = 20) received local wound infiltration at end of surgery with 40 ml of bupivacaine 0.25%. A standardized postoperative analgesic regimen composed of intravenous paracetamol and a morphine patient-controlled analgesia (PCA). The use of intraoperative fentanyl and recovery room morphine boluses, PCA-administered morphine, pain scores as well as number of patients' experienced postoperative nausea and vomiting in the ward at 6 and 24 h were recorded. Group 1 patients received a significantly lower cumulative intraoperative fentanyl, significantly lesser boluses of morphine in postanesthesia care unit, as well, significantly lower cumulative 24 h postoperative morphine dosage than the group 2 patients. Pain visual analog scale scores were significantly lower at both 6 and 24 h postoperatively in TAP group when compared with the no-TAP group. There were no complications related to the TAP block procedures. No signs or symptoms of local anesthetic systemic toxicity were detected. The combination of bilateral US-guided RS and TAP blocks provides excellent perioperative analgesia for major upper abdominal surgery.

  15. Fermi surface interconnectivity and topology in Weyl fermion semimetals TaAs, TaP, NbAs, and NbP

    DOE PAGES

    Lee, Chi-Cheng; Xu, Su-Yang; Huang, Shin-Ming; ...

    2015-12-01

    The family of binary compounds including TaAs, TaP, NbAs, and NbP was recently discovered as the first realization of Weyl semimetals. In order to develop a comprehensive description of the charge carriers in these Weyl semimetals, we performed detailed and systematic electronic band structure calculations which reveal the nature of Fermi surfaces and their complex interconnectivity in TaAs, TaP, NbAs, and NbP. In conclusion, our work reports a comparative and comprehensive study of Fermi surface topology and band structure details of all known members of the Weyl semimetal family and hence provides the fundamental knowledge for realizing the many predictedmore » exotic topological quantum physics of Weyl semimetals based on the TaAs class of materials.« less

  16. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-192- Ashe-Hanford/Scooteney-Tap

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hutchinson, Ken

    2004-01-26

    Vegetation Management for the Ashe-Hanford (tower 13/1 to 15/2) and Scooteney Tap (tower 2/1+1200 to 4/1+50) line corridor. The Ashe-Hanford line is a 500 kV single circuit transmission line having an easement width of 350 feet. The Scooteney Tap line is a 230 kV single circuit line having an easement width of 262.5 feet on the Department of Energy’s Hanford Nuclear Reservation (Reservation) and an easement width of 100 feet on private lands. The proposed work will be accomplished in the indicated sections of the transmission lines as referenced on the attached checklist. The work will include the performance ofmore » tower pad maintenance and access road maintenance in the referenced areas. Maintenance will include the control of all brush species within 30 feet of transmission structures and controlling all vegetation, except grass along the access roads to provide a 14-foot width for travel. Noxious weed management will also occur on the rights-of- way where needed.« less

  17. Fast and "green" method for the analytical monitoring of haloketones in treated water.

    PubMed

    Serrano, María; Silva, Manuel; Gallego, Mercedes

    2014-09-05

    Several groups of organic compounds have emerged as being particularly relevant as environmental pollutants, including disinfection by-products (DBPs). Haloketones (HKs), which belong to the unregulated volatile fraction of DBPs, have become a priority because of their occurrence in drinking water at concentrations below 1μg/L. The absence of a comprehensive method for HKs has led to the development of the first method for determining fourteen of these species. In an effort to miniaturise, this study develops a micro liquid-liquid extraction (MLLE) method adapted from EPA Method 551.1. In this method practically, the whole extract (50μL) was injected into a programmed temperature vaporiser-gas chromatography-mass spectrometer in order to improve sensitivity. The method was validated by comparing it to EPA Method 551.1 and showed relevant advantages such as: lower sample pH (1.5), higher aqueous/organic volume ratio (60), lower solvent consumption (200μL) and fast and cost-saving operation. The MLLE method achieved detection limits ranging from 6 to 60ng/L (except for 1,1,3-tribromo-3-chloroacetone, 120ng/L) with satisfactory precision (RSD, ∼6%) and high recoveries (95-99%). An evaluation was carried out of the influence of various dechlorinating agents as well as of the sample pH on the stability of the fourteen HKs in treated water. To ensure the HKs integrity for at least 1 week during storage at 4°C, the samples were acidified at pH ∼1.5, which coincides with the sample pH required for MLLE. The green method was applied to the speciation of fourteen HKs in tap and swimming pool waters, where one and seven chlorinated species, respectively, were found. The concentration of 1.1-dichloroacetone in swimming pool water increased ∼25 times in relation to tap water. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Influence of the magnetic field profile on ITER conductor testing

    NASA Astrophysics Data System (ADS)

    Nijhuis, A.; Ilyin, Y.; ten Kate, H. H. J.

    2006-08-01

    We performed simulations with the numerical CUDI-CICC code on a typical short ITER (International Thermonuclear Experimental Reactor) conductor test sample of dual leg configuration, as usually tested in the SULTAN test facility, and made a comparison with the new EFDA-Dipole test facility offering a larger applied DC field region. The new EFDA-Dipole test facility, designed for short sample testing of conductors for ITER, has a homogeneous high field region of 1.2 m, while in the SULTAN facility this region is three times shorter. The inevitable non-uniformity of the current distribution in the cable, introduced by the joints at both ends, has a degrading effect on voltage-current (VI) and voltage-temperature (VT) characteristics, particularly for these short samples. This can easily result in an underestimation or overestimation of the actual conductor performance. A longer applied DC high field region along a conductor suppresses the current non-uniformity by increasing the overall longitudinal cable electric field when reaching the current sharing mode. The numerical interpretation study presented here gives a quantitative analysis for a relevant practical case of a test of a short sample poloidal field coil insert (PFCI) conductor in SULTAN. The simulation includes the results of current distribution analysis from self-field measurements with Hall sensor arrays, current sharing measurements and inter-petal resistance measurements. The outcome of the simulations confirms that the current uniformity improves with a longer high field region but the 'measured' VI transition is barely affected, though the local peak voltages become somewhat suppressed. It appears that the location of the high field region and voltage taps has practically no influence on the VI curve as long as the transverse voltage components are adequately cancelled. In particular, for a thin conduit wall, the voltage taps should be connected to the conduit in the form of an (open) azimuthally soldered wire, averaging the transverse conduit surface potentials initiated in the joints.

  19. Selective and sensitive detection of chromium(VI) in waters using electrospray ionization mass spectrometry.

    PubMed

    Weldy, Effie; Wolff, Chloe; Miao, Zhixin; Chen, Hao

    2013-09-01

    From 2000 through 2011, there were 14 criminal cases of violations of the Clean Water Act involving the discharge of chromium, a toxic heavy metal, into drinking and surface water sources. As chromium(VI), a potential carcinogen present in the environment, represents a significant safety concern, it is currently the subject of an EPA health risk assessment. Therefore, sensitive and selective detection of this species is highly desired. This study reports the analysis of chromium(VI) in water samples by electrospray ionization mass spectrometry (ESI-MS) following its reduction and complexation with ammonium pyrrolidinedithiocarbamate (APDC). The reduction and subsequent complexation produce a characteristic [Cr(III)O]-PDC complex which can be detected as a protonated ion of m/z 507 in the positive ion mode. The detection is selective to chromium(VI) under acidic pH, even in the presence of chromium(III) and other metal ions, providing high specificity. Different water samples were examined, including deionized, tap, and river waters, and sensitive detection was achieved. In the case of deionized water, quantification over the concentration range of 3.7 to 148ppb gave an excellent correlation coefficient of 0.9904 using the enhanced MS mode scan. Using the single-reaction monitoring (SRM) mode (monitoring the characteristic fragmentation of m/z 507 to m/z 360), the limit of detection (LOD) was found to be 0.25ppb. The LOD of chromium(VI) for both tap and river water samples was determined to be 2.0ppb. A preconcentration strategy using simple vacuum evaporation of the aqueous sample was shown to further improve the ESI signal by 15 fold. This method, with high sensitivity and selectivity, should provide a timely solution for the real-world analysis of toxic chromium(VI). Copyright © 2012 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  20. Quantification and characterization of microbial biofilm community attached on the surface of fermentation vessels used in green table olive processing.

    PubMed

    Grounta, Athena; Doulgeraki, Agapi I; Panagou, Efstathios Z

    2015-06-16

    The aim of the present study was the quantification of biofilm formed on the surface of plastic vessels used in Spanish-style green olive fermentation and the characterization of the biofilm community by means of molecular fingerprinting. Fermentation vessels previously used in green olive processing were subjected to sampling at three different locations, two on the side and one on the bottom of the vessel. Prior to sampling, two cleaning treatments were applied to the containers, including (a) washing with hot tap water (60 °C) and household detergent (treatment A) and (b) washing with hot tap water, household detergent and bleach (treatment B). Population (expressed as log CFU/cm(2)) of total viable counts (TVC), lactic acid bacteria (LAB) and yeasts were enumerated by standard plating. Bulk cells (whole colonies) from agar plates were isolated for further characterization by PCR-DGGE. Results showed that regardless of the cleaning treatment no significant differences were observed between the different sampling locations in the vessel. The initial microbial population before cleaning ranged between 3.0-4.5 log CFU/cm(2) for LAB and 4.0-4.6 log CFU/cm(2) for yeasts. Cleaning treatments exhibited the highest effect on LAB that were recovered at 1.5 log CFU/cm(2) after treatment A and 0.2 log CFU/cm(2) after treatment B, whereas yeasts were recovered at approximately 1.9 log CFU/cm(2) even after treatment B. High diversity of yeasts was observed between the different treatments and sampling spots. The most abundant species recovered belonged to Candida genus, while Wickerhamomyces anomalus, Debaryomyces hansenii and Pichia guilliermondii were frequently detected. Among LAB, Lactobacillus pentosus was the most abundant species present on the abiotic surface of the vessels. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Synchronized tapping facilitates learning sound sequences as indexed by the P300.

    PubMed

    Kamiyama, Keiko S; Okanoya, Kazuo

    2014-01-01

    The purpose of the present study was to determine whether and how single finger tapping in synchrony with sound sequences contributed to the auditory processing of them. The participants learned two unfamiliar sound sequences via different methods. In the tapping condition, they learned an auditory sequence while they tapped in synchrony with each sound onset. In the no tapping condition, they learned another sequence while they kept pressing a key until the sequence ended. After these learning sessions, we presented the two melodies again and recorded event-related potentials (ERPs). During the ERP recordings, 10% of the tones within each melody deviated from the original tones. An analysis of the grand average ERPs showed that deviant stimuli elicited a significant P300 in the tapping but not in the no-tapping condition. In addition, the significance of the P300 effect in the tapping condition increased as the participants showed highly synchronized tapping behavior during the learning sessions. These results indicated that single finger tapping promoted the conscious detection and evaluation of deviants within the learned sequences. The effect was related to individuals' musical ability to coordinate their finger movements along with external auditory events.

  2. Synchronized tapping facilitates learning sound sequences as indexed by the P300

    PubMed Central

    Kamiyama, Keiko S.; Okanoya, Kazuo

    2014-01-01

    The purpose of the present study was to determine whether and how single finger tapping in synchrony with sound sequences contributed to the auditory processing of them. The participants learned two unfamiliar sound sequences via different methods. In the tapping condition, they learned an auditory sequence while they tapped in synchrony with each sound onset. In the no tapping condition, they learned another sequence while they kept pressing a key until the sequence ended. After these learning sessions, we presented the two melodies again and recorded event-related potentials (ERPs). During the ERP recordings, 10% of the tones within each melody deviated from the original tones. An analysis of the grand average ERPs showed that deviant stimuli elicited a significant P300 in the tapping but not in the no-tapping condition. In addition, the significance of the P300 effect in the tapping condition increased as the participants showed highly synchronized tapping behavior during the learning sessions. These results indicated that single finger tapping promoted the conscious detection and evaluation of deviants within the learned sequences. The effect was related to individuals’ musical ability to coordinate their finger movements along with external auditory events. PMID:25400564

  3. Rapid method for monitoring N-nitrosodimethylamine in drinking water at the ng/L level without pre-concentration using high-performance liquid chromatography-chemiluminescence detection.

    PubMed

    Kodamatani, Hitoshi; Yamasaki, Hitomi; Sakaguchi, Takeru; Itoh, Shinya; Iwaya, Yoshimi; Saga, Makoto; Saito, Keiitsu; Kanzaki, Ryo; Tomiyasu, Takashi

    2016-08-19

    As a contaminant in drinking water, N-nitrosodimethylamine (NDMA) is of great concern because of its carcinogenicity; it has been limited to levels of ng/L by regulatory bodies worldwide. Consequently, a rapid and sensitive method for monitoring NDMA in drinking water is urgently required. In this study, we report an improvement of our previously proposed HPLC-based system for NDMA determination. The approach consists of the HPLC separation of NDMA, followed by NDMA photolysis to form peroxynitrite and detection with a luminol chemiluminescence reaction. The detection limit for the improved HPLC method was 0.2ng/L, which is 10 times more sensitive than our previously reported system. For tap water measurements, only the addition of an ascorbic acid solution to eliminate residual chlorine and passage through an Oasis MAX solid-phase extraction cartridge are needed. The proposed NDMA determination method requires a sample volume of less than 2mL and a complete analysis time of less than 15min per sample. The method was utilized for the long-term monitoring of NDMA in tap water. The NDMA level measured in the municipal water survey was 4.9ng/L, and a seasonal change of the NDMA concentration in tap water was confirmed. The proposed method should constitute a useful NDMA monitoring method for protecting drinking water quality. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Advanced analysis of finger-tapping performance: a preliminary study.

    PubMed

    Barut, Cağatay; Kızıltan, Erhan; Gelir, Ethem; Köktürk, Fürüzan

    2013-06-01

    The finger-tapping test is a commonly employed quantitative assessment tool used to measure motor performance in the upper extremities. This task is a complex motion that is affected by external stimuli, mood and health status. The complexity of this task is difficult to explain with a single average intertap-interval value (time difference between successive tappings) which only provides general information and neglects the temporal effects of the aforementioned factors. This study evaluated the time course of average intertap-interval values and the patterns of variation in both the right and left hands of right-handed subjects using a computer-based finger-tapping system. Cross sectional study. Thirty eight male individuals aged between 20 and 28 years (Mean±SD = 22.24±1.65) participated in the study. Participants were asked to perform single-finger-tapping test for 10 seconds of test period. Only the results of right-handed (RH) 35 participants were considered in this study. The test records the time of tapping and saves data as the time difference between successive tappings for further analysis. The average number of tappings and the temporal fluctuation patterns of the intertap-intervals were calculated and compared. The variations in the intertap-interval were evaluated with the best curve fit method. An average tapping speed or tapping rate can reliably be defined for a single-finger tapping test by analysing the graphically presented data of the number of tappings within the test period. However, a different presentation of the same data, namely the intertap-interval values, shows temporal variation as the number of tapping increases. Curve fitting applications indicate that the variation has a biphasic nature. The measures obtained in this study reflect the complex nature of the finger-tapping task and are suggested to provide reliable information regarding hand performance. Moreover, the equation reflects both the variations in and the general patterns associated with the task.

  5. Synthesis, characterization, and nonlinear optical properties of graphene oxide functionalized with tetra-amino porphyrin

    NASA Astrophysics Data System (ADS)

    Yamuna, R.; Ramakrishnan, S.; Dhara, Keerthy; Devi, R.; Kothurkar, Nikhil K.; Kirubha, E.; Palanisamy, P. K.

    2013-01-01

    The synthesis of a porphyrin-graphene oxide hybrid (GO-TAP) was carried out by covalently functionalizing graphene oxide (GO) with 5,10,15,20 mesotetra (4-aminophenyl) porphyrin (TAP) through an amide linkage. The GO-TAP hybrid has been characterized by Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, and UV-visible spectroscopy. The peak intensity of the Soret band of the material was suppressed compared to neat TAP. This indicates a strong interaction between the electronic energy level of TAP and GO in the GO-TAP hybrid. The functionalization of GO with TAP significantly improved its solubility and dispersion stability in organic solvents. Scanning electron micrographs reveal that the hybrid was found to be similar to the unmodified GO but slightly more wrinkled. Transmission electron micrographs also demonstrate that GO sheet in the hybrid is more wrinkled with some dark spot due to functionalization. Atomic force microscopy results also reveal that the TAP functionalization increases the thickness of GO sheet to 2.0-3.0 nm from 1.2 to 1.8 nm. We observed improved nonlinear optical and optical limiting properties for the hybrid compared to both graphene oxide and porphyrin. GO-TAP shows fluorescence quenching compared with porphyrin, indicating excellent electron and/or energy transfer to GO from TAP. Thermogravimetric analysis confirms that the GO-TAP hybrid has outstanding thermal stability.

  6. Multimedia Exposures to Arsenic and Lead for Children Near an Inactive Mine Tailings and Smelter Site

    PubMed Central

    Loh, Miranda M.; Sugeng, Anastasia; Lothrop, Nathan; Klimecki, Walter; Cox, Melissa; Wilkinson, Sarah T.; Lu, Zhenqiang; Beamer, Paloma I.

    2016-01-01

    Children living near contaminated mining waste areas may have high exposures to metals from the environment. This study investigates whether exposure to arsenic and lead is higher in children in a community near a legacy mine and smelter site in Arizona compared to children in other parts of the United States and the relationship of that exposure to the site. Arsenic and lead were measured in residential soil, house dust, tap water, urine, and toenail samples from 70 children in 34 households up to 7 miles from the site. Soil and house dust were sieved, digested, and analyzed via ICP-MS. Tap water and urine were analyzed without digestion, while toenails were washed, digested and analyzed. Blood lead was analyzed by an independent, certified laboratory. Spearman correlation coefficients were calculated between each environmental media and urine and toenails for arsenic and lead. Geometric mean arsenic (standard deviation) concentrations for each matrix were: 22.1 (2.59) ppm and 12.4 (2.27) ppm for soil and house dust (<63 μm), 5.71 (6.55) ppb for tap water, 14.0 (2.01) μg/L for specific gravity-corrected total urinary arsenic, 0.543 (3.22) ppm for toenails. Soil and vacuumed dust lead concentrations were 16.9 (2.03) ppm and 21.6 (1.90) ppm. The majority of blood lead levels were below the limit of quantification. Arsenic and lead concentrations in soil and house dust decreased with distance from the site. Concentrations in soil, house dust, tap water, along with floor dust loading were significantly associated with toenail and urinary arsenic but not lead. Mixed models showed that soil and tap water best predicted urinary arsenic. In our study, despite being present in mine tailings at similar levels, internal lead exposure was not high, but arsenic exposure was of concern, particularly from soil and tap water. Naturally occurring sources may be an additional important contributor to exposures in certain legacy mining areas. PMID:26803211

  7. MRI and Neuropsychological Correlates in African Americans with Hypertension and left vEntricular Hypertrophy.

    PubMed

    Waldron-Perrine, B; Kisser, J E; Brody, A; Haacke, E M; Dawood, R; Millis, S; Levy, P

    2018-04-17

    African Americans (AA) are at high risk for hypertension (HTN) and poor blood pressure (BP) control. Persistently elevated BP contributes to cardiovascular morbidity. White matter hyperintensities (WMH) are a definable magnetic resonance imaging (MRI) marker of cerebrovascular injury linked to impairments in higher level thinking (i.e., executive functions), memory formation and speed of perceptual-motor processing. This sub-investigation evaluated neuropsychological functioning in association with WMH on brain MRIs in 23 otherwise healthy hypertensive AAs participating in an NIH-funded study of the effects of Vitamin D on BP and cardiac remodeling in AA patients 30-74 years of age with HTN and left ventricular hypertrophy. Neuropsychological assessment included psychomotor processing speed [(Symbol Digit Modality Test (SDMT) and Trail Making Test], executive functioning (Controlled Oral Word Association Test and Trail Making Test Part B), memory (Rey Auditory Verbal Learning Test), and fine motor functioning (Finger Tapping). Significant correlations (p< .05) were found between volume of periventricular lesions and Trails A (r = .51) and dominant hand finger tapping speed (r = -.69) and between subcortical lesion volume and Trails A (r = .60), both dominant (r = -.62) and non-dominant hand finger tapping speed (r = -.76) and oral SDMT (r = -.60); higher lesion volumes correlated to worse neuropsychological performance. Psychomotor tests including the Trail Making Test and finger tapping speed are sensitive indicators of subclinical deficits in mental processing speed and could serve as early markers of deep subcortical cerebrovascular injury in otherwise-healthy individuals with uncontrolled chronic HTN.

  8. The MindfulBreather: Motion Guided Mindfulness

    PubMed Central

    Mole, Tom B.; Galante, Julieta; Walker, Iona C.; Dawson, Anna F.; Hannah, Laura A.; Mackeith, Pieter; Ainslie, Mark; Jones, Peter B.

    2017-01-01

    For millennia, humans have focused their attention on the breath to develop mindfulness, but finding a scientific way to harness mindful breathing has proven elusive. Existing attempts to objectively measure and feedback on mindfulness have relied on specialist external hardware including electroencephalograms or respirometers that have been impractical for the majority of people learning to meditate. Consequently, training in the key skill of breath-awareness has lacked practical objective measures and guidance to enhance training. Here, we provide a brief technology report on an invention, The MindfulBreather® that addresses these issues. The technology is available to download embedded in a smartphone app that targets, measures and feedbacks on mindfulness of breathing in realtime to enhance training. The current article outlines only the technological concept with future studies quantifying efficacy, validity and reliability to be reported elsewhere. The MindfulBreather works by generating Motion Guided Mindfulness through interacting gyroscopic and touchscreen sensors in a three phase process: Mindfulness Induction (Phase I) gives standardized instruction to users to place their smartphone on their abdomen, breathe mindfully and to tap only at the peak of their inhalation. The smartphone’s gyroscope detects periodic tilts during breathing to generate sinusoidal waveforms. Waveform-tap patterns are analyzed to determine whether the user is mindfully tapping only at the correct phase of the breathing cycle, indicating psychobiological synchronization. Mindfulness Maintenance (Phase II) provides reinforcing pleasant feedback sounds each time a breath is mindfully tapped at the right time, and the App records a mindful breath. Lastly, data-driven Insights are fed back to the user (Phase III), including the number of mindful breaths tapped and breathing rate reductions associated with parasympathetic engagement during meditation. The new MGM technology is then evaluated and contrasted with traditional mindfulness approaches and a novel Psychobiological Synchronization Model is proposed. In summary, unlike existing technology, the MindfulBreather requires no external hardware and repurposes regular smartphones to deliver app-embedded Motion-Guided Mindfulness. Technological applications include reducing mindwandering and down-regulation of the brain’s default mode through enhanced mindful awareness. By objectively harnessing breath awareness, The MindfulBreather aims to realize the ancient human endeavor of mindfulness for the 21st century. PMID:29326571

  9. The MindfulBreather: Motion Guided Mindfulness.

    PubMed

    Mole, Tom B; Galante, Julieta; Walker, Iona C; Dawson, Anna F; Hannah, Laura A; Mackeith, Pieter; Ainslie, Mark; Jones, Peter B

    2017-01-01

    For millennia, humans have focused their attention on the breath to develop mindfulness, but finding a scientific way to harness mindful breathing has proven elusive. Existing attempts to objectively measure and feedback on mindfulness have relied on specialist external hardware including electroencephalograms or respirometers that have been impractical for the majority of people learning to meditate. Consequently, training in the key skill of breath-awareness has lacked practical objective measures and guidance to enhance training. Here, we provide a brief technology report on an invention, The MindfulBreather ® that addresses these issues. The technology is available to download embedded in a smartphone app that targets, measures and feedbacks on mindfulness of breathing in realtime to enhance training. The current article outlines only the technological concept with future studies quantifying efficacy, validity and reliability to be reported elsewhere. The MindfulBreather works by generating Motion Guided Mindfulness through interacting gyroscopic and touchscreen sensors in a three phase process: Mindfulness Induction (Phase I) gives standardized instruction to users to place their smartphone on their abdomen, breathe mindfully and to tap only at the peak of their inhalation. The smartphone's gyroscope detects periodic tilts during breathing to generate sinusoidal waveforms. Waveform-tap patterns are analyzed to determine whether the user is mindfully tapping only at the correct phase of the breathing cycle, indicating psychobiological synchronization. Mindfulness Maintenance (Phase II) provides reinforcing pleasant feedback sounds each time a breath is mindfully tapped at the right time, and the App records a mindful breath. Lastly, data-driven Insights are fed back to the user (Phase III), including the number of mindful breaths tapped and breathing rate reductions associated with parasympathetic engagement during meditation. The new MGM technology is then evaluated and contrasted with traditional mindfulness approaches and a novel Psychobiological Synchronization Model is proposed. In summary, unlike existing technology, the MindfulBreather requires no external hardware and repurposes regular smartphones to deliver app-embedded Motion-Guided Mindfulness. Technological applications include reducing mindwandering and down-regulation of the brain's default mode through enhanced mindful awareness. By objectively harnessing breath awareness, The MindfulBreather aims to realize the ancient human endeavor of mindfulness for the 21st century.

  10. Road Salt Transport at Two Municipal Wellfields in Wilmington, Massachusetts

    EPA Science Inventory

    Beginning in 2010, the USEPA and the Town of Wilmington collected monthly samples of wellfield raw water and surface water for inorganic analyses. Dataloggers recording temperature and specific conductivity every 15 minutes at key locations in streams and in the raw water taps o...

  11. 40 CFR 141.80 - General requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) NATIONAL PRIMARY DRINKING WATER REGULATIONS Control of Lead and Copper § 141.80 General requirements. (a... drinking water regulations for lead and copper. Unless otherwise indicated, each of the provisions of this... and copper action levels measured in samples collected at consumers' taps. (c) Lead and copper action...

  12. More than just tapping: index finger-tapping measures procedural learning in schizophrenia.

    PubMed

    Da Silva, Felipe N; Irani, Farzin; Richard, Jan; Brensinger, Colleen M; Bilker, Warren B; Gur, Raquel E; Gur, Ruben C

    2012-05-01

    Finger-tapping has been widely studied using behavioral and neuroimaging paradigms. Evidence supports the use of finger-tapping as an endophenotype in schizophrenia, but its relationship with motor procedural learning remains unexplored. To our knowledge, this study presents the first use of index finger-tapping to study procedural learning in individuals with schizophrenia or schizoaffective disorder (SCZ/SZA) as compared to healthy controls. A computerized index finger-tapping test was administered to 1169 SCZ/SZA patients (62% male, 88% right-handed), and 689 healthy controls (40% male, 93% right-handed). Number of taps per trial and learning slopes across trials for the dominant and non-dominant hands were examined for motor speed and procedural learning, respectively. Both healthy controls and SCZ/SZA patients demonstrated procedural learning for their dominant hand but not for their non-dominant hand. In addition, patients showed a greater capacity for procedural learning even though they demonstrated more variability in procedural learning compared to healthy controls. Left-handers of both groups performed better than right-handers and had less variability in mean number of taps between non-dominant and dominant hands. Males also had less variability in mean tap count between dominant and non-dominant hands than females. As expected, patients had a lower mean number of taps than healthy controls, males outperformed females and dominant-hand trials had more mean taps than non-dominant hand trials in both groups. The index finger-tapping test can measure both motor speed and procedural learning, and motor procedural learning may be intact in SCZ/SZA patients. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Hematological disorders at birth in complicated monochorionic twins.

    PubMed

    Verbeek, Lianne; Slaghekke, Femke; Sueters, Marieke; Middeldorp, Johanna M; Klumper, Frans J; Haak, Monique C; Oepkes, Dick; Lopriore, Enrico

    2017-06-01

    Monochorionic twins are at risk of severe complications including twin-twin transfusion syndrome (TTTS), twin anemia-polycythemia sequence (TAPS) and acute peripartum TTTS. The pathophysiology is based on inter-twin blood transfusion through placental vascular anastomoses. Areas covered: This review focuses on the incidence, management and outcome of neonatal hematological complications at birth in TTTS, TAPS and acute peripartum TTTS. Expert commentary: Hematological disorders are often present at birth in monochorionic twins and include acute or chronic anemia, polycythemia and thrombocytopenia. Routine measurement of complete blood counts in all complicated monochorionic twins is strongly recommended. Increased awareness on these disorders and correct diagnostic tests will lead to prompt and adequate management at birth.

  14. Cross-cultural comparison of neurobehavioral performance in Asian workers.

    PubMed

    Chung, Jong-Hak; Sakong, Joon; Kang, Pock-Soo; Kim, Chang-Yoon; Lee, Kyeong-Soo; Jeon, Man-Joong; Sung, Nak-Jung; Ahn, Sang-Ho; Won, Kyu-Chang

    2003-08-01

    Widely-used neurobehavioral tests have been developed and standardized on Western populations, but studies on subject factors for Asian populations have been very limited. For the effective application and interpretation of neurobehavioral tests in Asian populations, an evaluation of the effects of subject factors, including cultural background, is necessary. A cross-cultural study was conducted to evaluate the effects of cultural background and the interaction between cultural background and education on neurobehavioral tests in Asian populations. The Korean version of the Swedish Performance Evaluation System (Simple Reaction Time, Symbol Digit, and Finger Tapping Speed) and a pegboard test were administered to 537 workers who were not exposed to chemicals at work from Fareast (Korea and Chinese), Central (Uzbekistan and Tajikistan), and South Asia (Sri Lanka and Indonesia). The Fareast Asian group exhibited better performance in adjusted test scores than other Asian groups, achieving significance for Symbol Digit and Finger Tapping Speed in both genders. The magnitude of the effect of cultural background on Symbol Digit was comparable to the effect of about 10 years of education. Cultural background did not modify the relation between years of education and Symbol Digit in either males or females. This study may provide the first evidence that cultural background has a large impact on neurobehavioral test performance, even within Asian populations, and suggests that cultural background is a critical confounding factor that must be controlled in epidemiologic studies which include Asian populations in the sample.

  15. Estimation of optimal concentration of fluoride in drinking water under conditions prevailing in Chile.

    PubMed

    Villa, A E; Guerrero, S; Villalobos, J

    1998-08-01

    The purpose of this comparative study of caries and dental fluorosis experience in Chilean children was to estimate the optimal range of fluoride concentration in tap water under conditions currently prevailing in Chile. The sample included 2431 schoolchildren 7, 12 and 15 years old, life-long residents of five communities with fluoride concentrations in their tap water in the range 0.07-1.1 mg/L. The study population received an oral clinical examination including caries experience and an enamel fluorosis evaluation of the permanent dentition (Dean's scoring system). For 15-year-old children, the DMFT index changed from 5.06 to 2.60, and for 12-year-olds it changed from 3.10 to 1.36 when fluoride water concentration changed from 0.07 to 1.10 mg/L. For 7-year-old children the dmft index correspondingly changed from 3.67 to 1.59. The relationship between DMFT for 12-year-olds and water fluoride concentration was best fitted by a logarithmic function (r2=0.98). The Community Fluorosis Index (CFI) was used to assess enamel fluorosis in the study population, and it showed a linear relationship (r2=0.983) with increasing fluoride concentration of water for the 12-year-old group. Results obtained suggest that under current Chilean conditions, the optimal range of fluoride concentration in potable water should lie in the 0.5-0.6 mg/L range.

  16. Fast trace determination of nine odorant and estrogenic chloro- and bromo-phenolic compounds in real water samples through automated solid-phase extraction coupled with liquid chromatography tandem mass spectrometry.

    PubMed

    Yuan, Su-Fen; Liu, Ze-Hua; Lian, Hai-Xian; Yang, Chuang-Tao; Lin, Qing; Yin, Hua; Lin, Zhang; Dang, Zhi

    2018-02-01

    A fast and reliable method was developed for simultaneous trace determination of nine odorous and estrogenic chloro- and bromo-phenolic compounds (CPs and BPs) in water samples using solid-phase extraction (SPE) coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS). For sample preparation, the extraction efficiencies of two widely applied cartridges Oasis HLB and Sep-Pak C18 were compared, and the Oasis HLB cartridge showed much better extraction performance; pH of water sample also plays important role on extraction, and pH = 2-3 was found to be most appropriate. For separation of the target compounds, small addition of ammonium hydroxide can obviously improve the detection sensitivity, and the optimized addition concentration was determined as 0.2%. The developed efficient method was validated and showed excellent linearity (R 2  > 0.995), low limit of detection (LOD, 1.9-6.2 ng/L), and good recovery efficiencies of 57-95% in surface and tap water with low relative standard deviation (RSD, 1.3-17.4%). The developed method was finally applied to one tap and one surface water samples and most of these nine targets were detected, but all of them were below their odor thresholds, and their estrogen equivalent (EEQ) were also very low.

  17. Magnetic solid-phase extraction of tetracyclines using ferrous oxide coated magnetic silica microspheres from water samples.

    PubMed

    Lian, Lili; Lv, Jinyi; Wang, Xiyue; Lou, Dawei

    2018-01-26

    A novel magnetic solid-phase extraction approach was proposed for extraction of potential residues of tetracyclines (TCs) in tap and river water samples, based on Fe 3 O 4 @SiO 2 @FeO magnetic nanocomposite. Characterized results showed that the received Fe 3 O 4 @SiO 2 @FeO had distinguished magnetism and core-shell structure. Modified FeO nanoparticles with an ∼5 nm size distribution were homogeneously dispersed on the surface of the silica shell. Owing to the strong surface affinity of Fe (II) toward TCs, the magnetic nanocomposite could be applied to efficiently extract three TCs antibiotics, namely, oxytetracycline, tetracycline and chlortetracycline from water samples. Several factors, such as sorbent amount, pH condition, adsorption and desorption time, desorption solvent, selectivity and sample volume, influencing the extraction performance of TCs were investigated and optimized. The developed method showed excellent linearity (R > 0.9992) in the range of 0.133-333 μg L -1 , under optimized conditions. The limits of detection were between 0.027 and 0.107 μg L -1 for oxytetracycline, tetracycline and chlortetracycline, respectively. The feasibility of this method was evaluated by analysis of tap and river water samples. The recoveries at the spiked concentration levels ranged from 91.0% to 104.6% with favorable reproducibility (RSD < 4%). Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Development of a diagnostic system for bilirubin detection in cerebral spinal fluid

    NASA Astrophysics Data System (ADS)

    Bhadri, Prashant R.; Salgaonkar, Vasant A.; Majumdar, Anindya; Morgan, Chad J.; Zuccarello, Mario; Pyne, Gail J.; Dulaney, Elizabeth; Caffery, James, Jr.; Shukla, Rakesh; Beyette, Fred R., Jr.

    2004-11-01

    A weakened portion of an artery in the brain leads to a medical condition known as a cerebral aneurysm. A subarachnoid hemorrhage (SAH) occurs when an aneurysm ruptures. For those individuals suspected of having a SAH, a computerized tomography (CT) scan of the brain usually demonstrates evidence of the bleeding. However, in a considerable portion of people, the CT scan is unable to detect the blood that has escaped from the blood vessel. Recent studies have indicated nearly 30% of patients with a SAH are initially misdiagnosed. For circumstances when a SAH is suspected despite a normal CT scan, physicians make the diagnosis of SAH by performing a spinal tap. A spinal tap uses a needle to sample the cerebrospinal fluid (CSF) collected from the patient"s lumbar spine. However, it is also possible for blood to be introduced into the CSF as a result of the spinal tap procedure. Therefore, an effective solution is required to help medical personnel differentiate between the blood that results from a tap and that from a ruptured aneurysm. In this paper, the development of a prototype is described which is sensitive and specific for measuring bilirubin in CSF, hemorrhagic-CSF and CSF-like solutions. To develop this instrument a combination of spectrophotometric analysis, custom data analysis software and other hardware interfaces are assembled that lay the foundation for the development of portable and user-friendly equipment suitable for assisting trained medical personnel with the diagnosis of a ruptured cerebral aneurysm.

  19. Pollution by Nonylphenol in river, tap water, and aquatic in an acid rain-plagued city in southwest China.

    PubMed

    Jie, Yu; Jie, Zhou; Ya, Luo; Xuesong, Yang; Jing, Yang; Yu, Yang; Jiaqi, Yang; Jie, Xu

    2017-06-01

    Nonylphenol (NP) has provoked much environmental concern because of their weak estrogenic activities; however, few data are available on the environmental levels of the chemical in China. Environmental or river samples were assayed for NP by high-performance liquid chromatography (HPLC) technique. The concentration for NP measured in Xiangjiang River, ranging from 0.174 to 3.411 μg/L with a mean value of 1.73 μg/L, was lower than the Water Quality Criteria for NP of the US (6.6 μg/L); however, the NP concentration was maintained at a higher level compare to the developed countries and other civil cities. NP concentration in downstream water was markedly higher than that both in midstream and upstream water. Tissue accumulation of NP was observed in aquatics. A ratio of mean concentration of NP in aquatic (chlamys farreri and hemiculter leucisculus) to that in river water was 241 and 1087, respectively. The presence of NP in tap water in two urban districts of Zunyi was common with a detectable rate reached 100.0%. Mean NP concentration in terminal tap water in Huichuan district was six times as high as Honghuagang district, which was above Standards for the Drinking Water Quality for Phenols of China (2 μg/L). The pollution of NP in Xiangjiang River, tap water, and aquatic in Zunyi belongs to moderate or severe level in the world.

  20. Comammox in drinking water systems.

    PubMed

    Wang, Yulin; Ma, Liping; Mao, Yanping; Jiang, Xiaotao; Xia, Yu; Yu, Ke; Li, Bing; Zhang, Tong

    2017-06-01

    The discovery of complete ammonia oxidizer (comammox) has fundamentally upended our perception of the global nitrogen cycle. Here, we reported four metagenome assembled genomes (MAGs) of comammox Nitrospira that were retrieved from metagenome datasets of tap water in Singapore (SG-bin1 and SG-bin2), Hainan province, China (HN-bin3) and Stanford, CA, USA (ST-bin4). Genes of phylogenetically distinct ammonia monooxygenase subunit A (amoA) and hydroxylamine dehydrogenase (hao) were identified in these four MAGs. Phylogenetic analysis based on ribosomal proteins, AmoA, hao and nitrite oxidoreductase (subunits nxrA and nxrB) sequences indicated their close relationships with published comammox Nitrospira. Canonical ammonia-oxidizing microbes (AOM) were also identified in the three tap water samples, ammonia-oxidizing bacteria (AOB) in Singapore's and Stanford's samples and ammonia-oxidizing archaea (AOA) in Hainan's sample. The comammox amoA-like sequences were also detected from some other drinking water systems, and even outnumbered the AOA and AOB amoA-like sequences. The findings of MAGs and the occurrences of AOM in different drinking water systems provided a significant clue that comammox are widely distributed in drinking water systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

Top