Sample records for samples previously determined

  1. Comparison study of two procedures for the determination of emamectin benzoate in medicated fish feed.

    PubMed

    Farer, Leslie J; Hayes, John M

    2005-01-01

    A new method has been developed for the determination of emamectin benzoate in fish feed. The method uses a wet extraction, cleanup by solid-phase extraction, and quantitation and separation by liquid chromatography (LC). In this paper, we compare the performance of this method with that of a previously reported LC assay for the determination of emamectin benzoate in fish feed. Although similar to the previous method, the new procedure uses a different sample pretreatment, wet extraction, and quantitation method. The performance of the new method was compared with that of the previously reported method by analyses of 22 medicated feed samples from various commercial sources. A comparison of the results presented here reveals slightly lower assay values obtained with the new method. Although a paired sample t-test indicates the difference in results is significant, this difference is within the method precision of either procedure.

  2. Quantitative determination of mineral composition by powder x-ray diffraction

    DOEpatents

    Pawloski, G.A.

    1984-08-10

    An external standard intensity ratio method is used for quantitatively determining mineralogic compositions of samples by x-ray diffraction. The method uses ratios of x-ray intensity peaks from a single run. Constants are previously determined for each mineral which is to be quantitatively measured. Ratios of the highest intensity peak of each mineral to be quantified in the sample and the highest intensity peak of a reference mineral contained in the sample are used to calculate sample composition.

  3. Quantitative determination of mineral composition by powder X-ray diffraction

    DOEpatents

    Pawloski, Gayle A.

    1986-01-01

    An external standard intensity ratio method is used for quantitatively determining mineralogic compositions of samples by x-ray diffraction. The method uses ratios of x-ray intensity peaks from a single run. Constants are previously determined for each mineral which is to be quantitatively measured. Ratios of the highest intensity peak of each mineral to be quantified in the sample and the highest intensity peak of a reference mineral contained in the sample are used to calculate sample composition.

  4. The Comparison of Detrital Zircon Ages to Point Count Provenance Analysis for the Pottsville Sandstone in the Northern Appalachian Foreland Basin Venango County, Pennsylvania

    NASA Astrophysics Data System (ADS)

    Loveday, S.; Harris, D. B.; Schiappa, T.; Pecha, M.

    2017-12-01

    The specific sources of sediments deposited in the Appalachian basin prior to and immediately following the Alleghenian orogeny has long been a topic of debate. Recent advances in U-Pb dating of detrital zircons have greatly helped to determine some of the sources of these sediments. For this study, sandstone samples were collected from the Pottsville Formation in the northern Appalachian Foreland Basin, Venango County, Pennsylvania to provide supplementary data for previous work that sought to describe the provenance of the same sediments by point counts of thin sections of the same units. Results of this previous work established that the provenance for these units was transitional recycled orogenic, including multiple recycled sediments, and that a cratonic contribution was not able to be determined clearly. The previous results suggested that the paleoenvironment was a fluvial dominated delta prograding in the northern direction. However, no geochronologic data was found during this study to confirm this interpretation. We sought to verify these results by U-Pb analysis of detrital zircons. Samples were collected from the areas where the previous research took place. U-Pb ages were found from sample at the highest elevation and lowest elevation. In the first sample, sample 17SL01 (younger sample stratigraphically), the zircons yield U-Pb age range peaks at 442-468 ma and 1037-1081 ma. The probability density plot for this specific sample displays a complete age gap from 500 ma to 811 ma. In the second sample, sample 17SL03 (older rock stratigraphically), the zircons yield U-Pb ages range peaks of 424-616 ma and 975-1057 ma. This sample doesn't show any ages younger than 424 ma and it doesn't display the sample age gap as sample 17SL01 does. The ages of zircons are consistent with thin section point counting provenance results from previous research suggesting zircon transport from the northern direction.

  5. Opportunistic pathology-based screening for diabetes

    PubMed Central

    Simpson, Aaron J; Krowka, Renata; Kerrigan, Jennifer L; Southcott, Emma K; Wilson, J Dennis; Potter, Julia M; Nolan, Christopher J; Hickman, Peter E

    2013-01-01

    Objective To determine the potential of opportunistic glycated haemoglobin (HbA1c) testing of pathology samples to detect previously unknown diabetes. Design Pathology samples from participants collected for other reasons and suitable for HbA1c testing were utilised for opportunistic diabetes screening. HbA1c was measured with a Biorad Variant II turbo analyser and HbA1c levels of ≥6.5% (48 mmol/mol) were considered diagnostic for diabetes. Confirmation of previously unknown diabetes status was obtained by a review of hospital medical records and phone calls to general practitioners. Setting Hospital pathology laboratory receiving samples from hospital-based and community-based (CB) settings. Participants Participants were identified based on the blood sample collection location in the CB, emergency department (ED) and inpatient (IP) groups. Exclusions pretesting were made based on the electronic patient history of: age <18 years, previous diabetes diagnosis, query for diabetes status in the past 12 months, evidence of pregnancy and sample collected postsurgery or transfusion. Only one sample per individual participant was tested. Results Of the 22 396 blood samples collected, 4505 (1142 CB, 1113 ED, 2250 IP) were tested of which 327 (7.3%) had HbA1c levels ≥6.5% (48 mmol/mol). Of these 120 (2.7%) were determined to have previously unknown diabetes (11 (1%) CB, 21 (1.9%) ED, 88 (3.9%) IP). The prevalence of previously unknown diabetes was substantially higher (5.4%) in hospital-based (ED and IP) participants aged over 54 years. Conclusions Opportunistic testing of referred pathology samples can be an effective method of screening for diabetes, especially in hospital-based and older persons. PMID:24065696

  6. Rapid determination of the isomeric truxillines in illicit cocaine via capillary gas chromatography/flame ionization detection and their use and implication in the determination of cocaine origin and trafficking routes.

    PubMed

    Mallette, Jennifer R; Casale, John F

    2014-10-17

    The isomeric truxillines are a group of minor alkaloids present in all illicit cocaine samples. The relative amount of truxillines in cocaine is indicative of the variety of coca used for cocaine processing, and thus, is useful in source determination. Previously, the determination of isomeric truxillines in cocaine was performed with a gas chromatography/electron capture detection method. However, due to the tedious sample preparation as well as the expense and maintenance required of electron capture detectors, the protocol was converted to a gas chromatography/flame-ionization detection method. Ten truxilline isomers (alpha-, beta-, delta-, epsilon-, gamma-, omega, zeta-, peri-, neo-, and epi-) were quantified relative to a structurally related internal standard, 4',4″-dimethyl-α-truxillic acid dimethyl ester. The method was shown to have a linear response from 0.001 to 1.00 mg/mL and a lower detection limit of 0.001 mg/mL. In this method, the truxillines are directly reduced with lithium aluminum hydride and then acylated with heptafluorobutyric anhydride prior to analysis. The analysis of more than 100 cocaine hydrochloride samples is presented and compared to data obtained by the previous methodology. Authentic cocaine samples obtained from the source countries of Colombia, Bolivia, and Peru were also analyzed, and comparative data on more than 23,000 samples analyzed over the past 10 years with the previous methodology is presented. Published by Elsevier B.V.

  7. Integrated proteomic and genomic analysis of colorectal cancer

    Cancer.gov

    Investigators who analyzed 95 human colorectal tumor samples have determined how gene alterations identified in previous analyses of the same samples are expressed at the protein level. The integration of proteomic and genomic data, or proteogenomics, pro

  8. Accounting for between-study variation in incremental net benefit in value of information methodology.

    PubMed

    Willan, Andrew R; Eckermann, Simon

    2012-10-01

    Previous applications of value of information methods for determining optimal sample size in randomized clinical trials have assumed no between-study variation in mean incremental net benefit. By adopting a hierarchical model, we provide a solution for determining optimal sample size with this assumption relaxed. The solution is illustrated with two examples from the literature. Expected net gain increases with increasing between-study variation, reflecting the increased uncertainty in incremental net benefit and reduced extent to which data are borrowed from previous evidence. Hence, a trial can become optimal where current evidence is sufficient assuming no between-study variation. However, despite the expected net gain increasing, the optimal sample size in the illustrated examples is relatively insensitive to the amount of between-study variation. Further percentage losses in expected net gain were small even when choosing sample sizes that reflected widely different between-study variation. Copyright © 2011 John Wiley & Sons, Ltd.

  9. Novel measuring strategies in neutron interferometry

    NASA Astrophysics Data System (ADS)

    Bonse, Ulrich; Wroblewski, Thomas

    1985-04-01

    Angular misalignment of a sample in a single crystal neutron interferometer leads to systematic errors of the effective sample thickness and in this way to errors in the determination of the coherent scattering length. The misalignment can be determined and the errors can be corrected by a second measurement at a different angular sample position. Furthermore, a method has been developed which allows supervision of the wavelength during the measurements. These two techniques were tested by determining the scattering length of copper. A value of bc = 7.66(4) fm was obtained which is in excellent agreement with previous measurements.

  10. Improved Method for Determination of Respiring Individual Microorganisms in Natural Waters

    PubMed Central

    Tabor, Paul S.; Neihof, Rex A.

    1982-01-01

    A method is reported that combines the microscopic determinations of specific, individual, respiring microorganisms by the detection of electron transport system activity and the total number of organisms of an estuarine population by epifluorescence microscopy. An active cellular electron transport system specifically reduces 2-(p-iodophenyl)-3-(p-nitrophenyl)-5-phenyl tetrazolium chloride (INT) to INT-formazan, which is recognized as opaque intracellular deposits in microorganisms stained with acridine orange. In a comparison of previously described sample preparation techniques, a loss of >70% of the counts of INT-reducing microorganisms was shown to be due to the dissolution of INT-formazan deposits by immersion oil (used in microscopy). In addition, significantly fewer fluorescing microorganisms and INT-formazan deposits, both ≤0.2 μm in size, were found for sample preparations that included a Nuclepore filter. Visual clarity was enhanced, and significantly greater direct counts and counts of INT-reducing microorganisms were recognized by transferring microorganisms from a filter to a gelatin film on a cover glass, followed by coating the sample with additional gelatin to produce a transparent matrix. With this method, the number of INT-reducing microorganisms determined for a Chesapeake Bay water sample was 2-to 10-fold greater than the number of respiring organisms reported previously for marine or freshwater samples. INT-reducing microorganisms constituted 61% of the total direct counts determined for a Chesapeake Bay water sample. This is the highest percentage of metabolically active microorganisms of any aquatic population reported using a method which determines both total counts and specific activity. PMID:16346025

  11. Improved method for determination of respiring individual microorganisms in natural waters.

    PubMed

    Tabor, P S; Neihof, R A

    1982-06-01

    A method is reported that combines the microscopic determinations of specific, individual, respiring microorganisms by the detection of electron transport system activity and the total number of organisms of an estuarine population by epifluorescence microscopy. An active cellular electron transport system specifically reduces 2-(p-iodophenyl)-3-(p-nitrophenyl)-5-phenyl tetrazolium chloride (INT) to INT-formazan, which is recognized as opaque intracellular deposits in microorganisms stained with acridine orange. In a comparison of previously described sample preparation techniques, a loss of >70% of the counts of INT-reducing microorganisms was shown to be due to the dissolution of INT-formazan deposits by immersion oil (used in microscopy). In addition, significantly fewer fluorescing microorganisms and INT-formazan deposits, both

  12. High energy PIXE: A tool to characterize multi-layer thick samples

    NASA Astrophysics Data System (ADS)

    Subercaze, A.; Koumeir, C.; Métivier, V.; Servagent, N.; Guertin, A.; Haddad, F.

    2018-02-01

    High energy PIXE is a useful and non-destructive tool to characterize multi-layer thick samples such as cultural heritage objects. In a previous work, we demonstrated the possibility to perform quantitative analysis of simple multi-layer samples using high energy PIXE, without any assumption on their composition. In this work an in-depth study of the parameters involved in the method previously published is proposed. Its extension to more complex samples with a repeated layer is also presented. Experiments have been performed at the ARRONAX cyclotron using 68 MeV protons. The thicknesses and sequences of a multi-layer sample including two different layers of the same element have been determined. Performances and limits of this method are presented and discussed.

  13. Exploring the Utilization of Low-Pressure, Piston-Cylinder Experiments to Determine the Bulk Compositions of Finite, Precious Materials

    NASA Technical Reports Server (NTRS)

    Vander Kaaden, K. E.; McCubbin, F. M.; Harrington, A. D.

    2017-01-01

    Determining the bulk composition of precious materials with a finite mass (e.g., meteorite samples) is extremely important in the fields of Earth and Planetary Science. From meteorite studies we are able to place constraints on large scale planetary processes like global differentiation and subsequent volcanism, as well as smaller scale processes like crystallization in a magma chamber or sedimentary compaction at the surface. However, with meteorite samples in particular, far too often we are limited by how precious the sample is as well as its limited mass. In this study, we have utilized aliquots of samples previously studied for toxicological hazards, including both the fresh samples (lunar mare basalt NWA 4734, lunar regolith breccia NWA 7611, martian basalt Tissint, martian regolith breccia NWA 7034, a vestian basalt Berthoud, a vestian regolith breccia NWA 2060, and a terrestrial mid-ocean ridge basalt (MORB)), and those that underwent iron leaching (Tissint, NWA 7034, NWA 4734, MORB). With these small masses of material, we performed low pressure (approx. 0.75 GPa), high temperature (greater than 1600 degrees Celsius) melting experiments. Each sample was analyzed using a JEOL 8530F electron microprobe to determine the bulk composition of the materials that were previously examined. When available, the results of our microprobe data were compared with bulk rock compositions in the literature. The results of this study show that with this technique, only approx. 50 mg of sample is required to accurately determine the bulk composition of the materials of interest.

  14. 43 CFR 11.64 - Injury determination phase-testing and sampling methods.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... In developing these objectives, the availability of information from response actions relating to the...), test cases proving the code works, and any alteration of previously documented code made to adapt the... computer code (if any), test cases proving the code works, and any alteration of previously documented code...

  15. 43 CFR 11.64 - Injury determination phase-testing and sampling methods.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... In developing these objectives, the availability of information from response actions relating to the...), test cases proving the code works, and any alteration of previously documented code made to adapt the... computer code (if any), test cases proving the code works, and any alteration of previously documented code...

  16. 43 CFR 11.64 - Injury determination phase-testing and sampling methods.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... In developing these objectives, the availability of information from response actions relating to the...), test cases proving the code works, and any alteration of previously documented code made to adapt the... computer code (if any), test cases proving the code works, and any alteration of previously documented code...

  17. SAVLOC, computer program for automatic control and analysis of X-ray fluorescence experiments

    NASA Technical Reports Server (NTRS)

    Leonard, R. F.

    1977-01-01

    A program for a PDP-15 computer is presented which provides for control and analysis of trace element determinations by using X-ray fluorescence. The program simultaneously handles data accumulation for one sample and analysis of data from previous samples. Data accumulation consists of sample changing, timing, and data storage. Analysis requires the locating of peaks in X-ray spectra, determination of intensities of peaks, identification of origins of peaks, and determination of a real density of the element responsible for each peak. The program may be run in either a manual (supervised) mode or an automatic (unsupervised) mode.

  18. Spectrophotometric determination of the tannin contents of various Turkish black tea, beer and wine samples.

    PubMed

    Tinkiliç, N; Uyanik, A

    2001-05-01

    This study reports tannin contents of various tea (19), beer (6) and wine (6) samples, produced or sold in Turkey under different brand names. Determinations were carried out by employing a previously reported UV-vis spectrophotometric method. The standard addition procedure was also compared to the direct determination procedure and found to be more reliable. The tannin contents of hot water extracts of tea, tea bag and herbal tea samples ranged between 6.20-8.33, 8.03-6.59 and 2.76-6.54 percent (w/w) respectively. Tannin contents of beer and wine samples determined without extraction were found ranging between 66.36-77.26 and 67.18-107.62 micrograms/mL respectively. Iron contents of analysed wine samples were also found ranging between 0.36 and 10.33 ppm by AAS and no relation is found between tannin and iron contents.

  19. The Use and Effectiveness of Triple Multiplex System for Coding Region Single Nucleotide Polymorphism in Mitochondrial DNA Typing of Archaeologically Obtained Human Skeletons from Premodern Joseon Tombs of Korea

    PubMed Central

    Oh, Chang Seok; Lee, Soong Deok; Kim, Yi-Suk; Shin, Dong Hoon

    2015-01-01

    Previous study showed that East Asian mtDNA haplogroups, especially those of Koreans, could be successfully assigned by the coupled use of analyses on coding region SNP markers and control region mutation motifs. In this study, we tried to see if the same triple multiplex analysis for coding regions SNPs could be also applicable to ancient samples from East Asia as the complementation for sequence analysis of mtDNA control region. By the study on Joseon skeleton samples, we know that mtDNA haplogroup determined by coding region SNP markers successfully falls within the same haplogroup that sequence analysis on control region can assign. Considering that ancient samples in previous studies make no small number of errors in control region mtDNA sequencing, coding region SNP analysis can be used as good complimentary to the conventional haplogroup determination, especially of archaeological human bone samples buried underground over long periods. PMID:26345190

  20. Palynology and age of some Cretaceous nonmarine deposits in Mongolia and China

    USGS Publications Warehouse

    Nichols, D.J.; Matsukawa, M.; Ito, M.

    2006-01-01

    To provide biostratigraphic and paleoecologic data for a major international project studying dinosaur trackways in eastern Asia, samples were collected for palynological analysis from the Choyr Basin of southeastern Mongolia and the Yanji Basin, Jilin Province, northeastern China. Palynologically productive samples from the Choyr Basin are from strata previously identified as either the Shinekhudag Formation or the Zuunbayan Formation but recently renamed the Khuren Dukh Formation; productive samples from the Yanji Basin are from the Tongfosi Formation. The biostratigraphically most important palynomorphs from both units are angiosperm pollen. The Khuren Dukh Formation is determined to be middle to late Albian in age. The Tongfosi Formation is determined to be early Cenomanian in age. These results conflict with some previously published interpretations of the ages of these units. Lacustrine depositional environments are indicated for both units by the presence of freshwater algae in both deposits. ?? 2006 Elsevier Ltd. All rights reserved.

  1. 7 CFR 42.132 - Determining cumulative sum values.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... the previous subgroup. (2) Subtract the subgroup tolerance (“T”). (3) The CuSum value is reset in the... 7 Agriculture 2 2010-01-01 2010-01-01 false Determining cumulative sum values. 42.132 Section 42... Determining cumulative sum values. (a) The parameters for the on-line cumulative sum sampling plans for AQL's...

  2. A Forensic Workshop Report Concerning (1) The Measurement and Analysis of Energetic Materials and (2) Databasing

    DTIC Science & Technology

    1999-01-01

    contaminating the surface. Research efforts to develop an improved sampling method have previously been limited to deposits made from solutions of explosives...explosive per fingerprint calculated in this way has too much variation to allow determination of sampling efficiency or to use this method to prepare...crystals is put into suspension, the actual amount is determined by usual methods including high-performance liquid chromatography (HPLC), gas

  3. Sample locality map and analytical data for potassium-argon ages in the Port Moller, Stepovak Bay, and Simeonof Island quadrangles, Alaska Peninsula

    USGS Publications Warehouse

    Wilson, Frederic H.; Shew, Nora B.; DuBois, Gregory D.; Bie, Scott W.

    1994-01-01

    Potassium-argon age determinations for 84 volcanic, intrusive, and hydrothermally altered rocks from the Port Moller, Stepovak Bay, and Simeonof Island quadrangles are reported here. Of these age determinations, 78 samples were analyzed as part of Alaska Mineral Resource Assessment Program (AMRAP) studies in the Port Moller, Stepovak Bay, and Simeonof Island quadrangles. Age deter- minations for 6 of the samples have been previously published (Burk, 1965; Kienle and Turner, 1976; Wilson and others, 1981). This report consists of a sample location map, analytical data (table 1), and rock descriptions (table 2).

  4. Derived Relational Responding: A Comparison of Match-to-Sample and the Relational Completion Procedure

    ERIC Educational Resources Information Center

    Dymond, Simon; Whelan, Robert

    2010-01-01

    Previous research suggests that the Relational Completion Procedure may be an effective alternative procedure for studying derived relational responding. However, the parameters that make it effective, relative to traditional match-to-sample, remain to be determined. The present experiment compared the Relational Completion Procedure and…

  5. COMPARISON OF ENTEROCCOCUS DENSITIES DETERMINED BY CULTURE AND QPCR ANALYSES IN WATER SAMPLES FROM TWO RECREATION BEACHES

    EPA Science Inventory

    Previous studies conducted by the U.S. Environmental Protection Agency (USEPA) have demonstrated that cell densities of the bacterial genus Enterococcus in water samples are directly correlated with gastroenteritis illness rates in swimmers at both marine and fresh water beaches....

  6. Round-robin study of arsenic implant dose measurement in silicon by SIMS

    NASA Astrophysics Data System (ADS)

    Simons, D.; Kim, K.; Benbalagh, R.; Bennett, J.; Chew, A.; Gehre, D.; Hasegawa, T.; Hitzman, C.; Ko, J.; Lindstrom, R.; MacDonald, B.; Magee, C.; Montgomery, N.; Peres, P.; Ronsheim, P.; Yoshikawa, S.; Schuhmacher, M.; Stockwell, W.; Sykes, D.; Tomita, M.; Toujou, F.; Won, J.

    2006-07-01

    An international round-robin study was undertaken under the auspices of ISO TC201/SC6 to determine the best analytical conditions and the level of interlaboratory agreement for the determination of the implantation dose of arsenic in silicon by secondary ion mass spectrometry (SIMS). Fifteen SIMS laboratories, as well as two laboratories that performed low energy electron-induced X-ray emission spectrometry (LEXES) and one that made measurements by instrumental neutron activation analysis (INAA) were asked to determine the implanted arsenic doses in three unknown samples using as a comparator NIST Standard Reference Material ® 2134. The use of a common reference material by all laboratories resulted in better interlaboratory agreement than was seen in a previous round-robin that lacked a common comparator. The relative standard deviation among laboratories was less than 4% for the medium-dose sample, but several percent larger for the low- and high-dose samples. The high-dose sample showed a significant difference between point-by-point and average matrix normalization because the matrix signal decreased in the vicinity of the implant peak, as observed in a previous study. The dose from point-by-point normalization was in close agreement with that determined by INAA. No clear difference in measurement repeatability was seen when comparing Si 2- and Si 3- as matrix references with AsSi -.

  7. Multiple-step preparation and physicochemical characterization of crystalline α-germanium hydrogenphosphate

    NASA Astrophysics Data System (ADS)

    Romano, Ricardo; Ruiz, Ana I.; Alves, Oswaldo L.

    2004-04-01

    The reaction between germanium oxide and phosphoric acid has previously been described and led to impure germanium hydrogenphosphate samples with low crystallinity. A new multiple-step route involving the same reaction under refluxing and soft hydrothermal conditions is described for the preparation of pure and crystalline α-GeP. The physicochemical characterization of the samples allows accompaniment of the reaction evolution as well as determining short- and long-range structural organization. The phase purity of the α-GeP sample was confirmed by applying Rietveld's profile analysis, which also determined the cell parameters of its crystals.

  8. 34 CFR 200.89 - MEP allocations; Re-interviewing; Eligibility documentation; and Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... determinations being tested) trained to conduct personal interviews and to understand and apply program... child eligibility determinations through the re-interview of a randomly selected sample of children previously identified as migratory. In conducting these re-interviews, an SEA must— (i) Use, at least once...

  9. 34 CFR 200.89 - MEP allocations; Re-interviewing; Eligibility documentation; and Quality control.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... determinations being tested) trained to conduct personal interviews and to understand and apply program... child eligibility determinations through the re-interview of a randomly selected sample of children previously identified as migratory. In conducting these re-interviews, an SEA must— (i) Use, at least once...

  10. A solid phase extraction-ion chromatography with conductivity detection procedure for determining cationic surfactants in surface water samples.

    PubMed

    Olkowska, Ewa; Polkowska, Żaneta; Namieśnik, Jacek

    2013-11-15

    A new analytical procedure for the simultaneous determination of individual cationic surfactants (alkyl benzyl dimethyl ammonium chlorides) in surface water samples has been developed. We describe this methodology for the first time: it involves the application of solid phase extraction (SPE-for sample preparation) coupled with ion chromatography-conductivity detection (IC-CD-for the final determination). Mean recoveries of analytes between 79% and 93%, and overall method quantification limits in the range from 0.0018 to 0.038 μg/mL for surface water and CRM samples were achieved. The methodology was applied to the determination of individual alkyl benzyl quaternary ammonium compounds in environmental samples (reservoir water) and enables their presence in such types of waters to be confirmed. In addition, it is a simpler, less time-consuming, labour-intensive, avoiding use of toxic chloroform and significantly less expensive methodology than previously described approaches (liquid-liquid extraction coupled with liquid chromatography-mass spectrometry). Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Ochratoxin A in cocoa and chocolate sampled in Canada.

    PubMed

    Turcotte, A-M; Scott, P M

    2011-06-01

    In order to determine the levels of ochratoxin A (OTA) in cocoa and cocoa products available in Canada, a previously published analytical method, with minor modifications to the extraction and immunoaffinity clean-up and inclusion of an evaporation step, was initially used (Method I). To improve the low method recoveries (46-61%), 40% methanol was then included in the aqueous sodium bicarbonate extraction solvent (pH 7.8) (Method II). Clean-up was on an Ochratest™ immunoaffinity column and OTA was determined by liquid chromatography (LC) with fluorescence detection. Recoveries of OTA from spiked cocoa powder (0.5 and 5 ng g(-1)) were 75-84%; while recoveries from chocolate were 93-94%. The optimized method was sensitive (limit of quantification (LOQ) = 0.07-0.08 ng g(-1)), accurate (recovery = 75-94%) and precise (coefficient of variation (CV) < 5%). It is applicable to cocoa and chocolate. Analysis of 32 samples of cocoa powder (16 alkalized and 16 natural) for OTA showed an incidence of 100%, with concentrations ranging from 0.25 to 7.8 ng g(-1); in six samples the OTA level exceeded 2 ng g(-1), the previously considered European Union limit for cocoa. The frequency of detection of OTA in 28 chocolate samples (21 dark or baking chocolate and seven milk chocolate) was also 100% with concentrations ranging from 0.05 to 1.4 ng g(-1); one sample had a level higher than the previously considered European Union limit for chocolate (1 ng g(-1)).

  12. Determination of fluoride in water - A modified zirconium-alizarin method

    USGS Publications Warehouse

    Lamar, W.L.

    1945-01-01

    A convenient, rapid colorimetric procedure using the zirconium-alizarin indicator acidified with sulfuric acid for the determination of fluoride in water is described. Since this acid indicator is stable indefinitely, it is more useful than other zirconium-alizarin reagents previously reported. The use of sulfuric acid alone in acidifying the zirconium-alizarin reagent makes possible the maximum suppression of the interference of sulfate. Control of the pH of the samples eliminates errors due to the alkalinity of the samples. The fluoride content of waters containing less than 500 parts per million of sulfate and less than 1000 p.p.m. of chloride may be determined within a limit of 0.1 p.p.m. when a 100-ml. sample is used.

  13. Determination of Zn/Cu ratio and oligoelements in serum samples by total reflection X-ray fluorescence spectrometry for cancer diagnosis

    NASA Astrophysics Data System (ADS)

    Marcó P., L. M.; Jiménez, E.; Hernández C., E. A.; Rojas, A.; Greaves, E. D.

    2001-11-01

    The method of quantification using the Compton peak as an internal standard, developed in a previous work, was applied to the routine determination of Fe, Cu, Zn and Se in serum samples from normal individuals and cancer patients by total reflection X-ray fluorescence spectrometry. Samples were classified according to age and sex of the donor, in order to determine reference values for normal individuals. Results indicate that the Zn/Cu ratio and the Cu concentration could prove to be useful tools for cancer diagnosis. Significant differences in these parameters between the normal and cancer group were found for all age ranges. The multielemental character of the technique, coupled with the small amounts of sample required and the short analysis time make it a valuable tool in clinical analysis.

  14. Psychometric properties of the Liebowitz Social Anxiety Scale (LSAS) in a longitudinal study of African Americans with anxiety disorders.

    PubMed

    Beard, Courtney; Rodriguez, Benjamin F; Moitra, Ethan; Sibrava, Nicholas J; Bjornsson, Andri; Weisberg, Risa B; Keller, Martin B

    2011-06-01

    The Liebowitz Social Anxiety Scale (LSAS) is a widely used measure of social anxiety. However, no study has examined the psychometric properties of the LSAS in an African American sample. The current study examined the LSAS characteristics in 97 African Americans diagnosed with an anxiety disorder. Overall, the original LSAS subscales showed excellent internal consistency and temporal stability. Similar to previous reports, fear and avoidance subscales were so highly correlated that they yielded redundant information. Confirmatory factor analyses for three previously proposed models failed to demonstrate an excellent fit to our data. However, a four-factor model showed minimally acceptable fit. Overall, the LSAS performed similarly in our African American sample as in previous European American samples. Exploratory factor analyses are warranted to determine whether a better factor structure exists for African Americans. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Predicting the required number of training samples. [for remotely sensed image data based on covariance matrix estimate quality criterion of normal distribution

    NASA Technical Reports Server (NTRS)

    Kalayeh, H. M.; Landgrebe, D. A.

    1983-01-01

    A criterion which measures the quality of the estimate of the covariance matrix of a multivariate normal distribution is developed. Based on this criterion, the necessary number of training samples is predicted. Experimental results which are used as a guide for determining the number of training samples are included. Previously announced in STAR as N82-28109

  16. The Structure of Intergenerational Relations in Rural China: A Latent Class Analysis

    ERIC Educational Resources Information Center

    Guo, Man; Chi, Iris; Silverstein, Merril

    2012-01-01

    Most existing typology studies of intergenerational relations have used samples in North America and Europe. The present study expands on previous research by determining whether similar family relation typologies could be found using a sample of Chinese rural elders. The data were derived from a survey of 1,224 older adults in China's rural Anhui…

  17. Update of membership and mean proper motion of open clusters from UCAC5 catalog

    NASA Astrophysics Data System (ADS)

    Dias, W. S.; Monteiro, H.; Assafin, M.

    2018-06-01

    We present mean proper motions and membership probabilities of individual stars for optically visible open clusters, which have been determined using data from the UCAC5 catalog. This follows our previous studies with the UCAC2 and UCAC4 catalogs, but now using improved proper motions in the GAIA reference frame. In the present study results were obtained for a sample of 1108 open clusters. For five clusters, this is the first determination of mean proper motion, and for the whole sample, we present results with a much larger number of identified astrometric member stars than on previous studies. It is the last update of our Open cluster Catalog based on proper motion data only. Future updates will count on astrometric, photometric and spectroscopic GAIA data as input for analyses.

  18. Determination of mercurous chloride and total mercury in mercury ores

    USGS Publications Warehouse

    Fahey, J.J.

    1937-01-01

    A method for the determination of mercurous chloride and total mercury on the same sample is described. The mercury minerals are volatilized in a glass tube and brought into intimate contact with granulated sodium carbonate. The chlorine is fixed as sodium chloride, determined with silver nitrate, and computed to mercurous chloride. The mercury is collected on a previously weighed gold coil and weighed.

  19. Uranium in NIMROC standard igneous rock samples

    NASA Technical Reports Server (NTRS)

    Rowe, M. W.; Herndon, J. M.

    1976-01-01

    Results are reported for analysis of the uranium in multiple samples of each of six igneous-rock standards (dunite, granite, lujavrite, norite, pyroxenite, and syenite) prepared as geochemical reference standards for elemental and isotopic compositions. Powdered rock samples were examined by measuring delayed neutron emission after irradiation with a flux of the order of 10 to the 13th power neutrons/sq cm per sec in a nuclear reactor. The measurements are shown to compare quite favorably with previous uranium determinations for other standard rock samples.

  20. On-line double isotope dilution laser ablation inductively coupled plasma mass spectrometry for the quantitative analysis of solid materials.

    PubMed

    Fernández, Beatriz; Rodríguez-González, Pablo; García Alonso, J Ignacio; Malherbe, Julien; García-Fonseca, Sergio; Pereiro, Rosario; Sanz-Medel, Alfredo

    2014-12-03

    We report on the determination of trace elements in solid samples by the combination of on-line double isotope dilution and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method requires the sequential analysis of the sample and a certified natural abundance standard by on-line IDMS using the same isotopically-enriched spike solution. In this way, the mass fraction of the analyte in the sample can be directly referred to the certified standard so the previous characterization of the spike solution is not required. To validate the procedure, Sr, Rb and Pb were determined in certified reference materials with different matrices, including silicate glasses (SRM 610, 612 and 614) and powdered samples (PACS-2, SRM 2710a, SRM 1944, SRM 2702 and SRM 2780). The analysis of powdered samples was carried out both by the preparation of pressed pellets and by lithium borate fusion. Experimental results for the analysis of powdered samples were in agreement with the certified values for all materials. Relative standard deviations in the range of 6-21% for pressed pellets and 3-21% for fused solids were obtained from n=3 independent measurements. Minimal sample preparation, data treatment and consumption of the isotopically-enriched isotopes are the main advantages of the method over previously reported approaches. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. The effect of salt crust on the thermal conductivity of one sample of fluvial particulate materials under Martian atmospheric pressures

    NASA Astrophysics Data System (ADS)

    Presley, Marsha A.; Craddock, Robert A.; Zolotova, Natalya

    2009-11-01

    A line-heat source apparatus was used to measure thermal conductivities of a lightly cemented fluvial sediment (salinity = 1.1 g · kg-1), and the same sample with the cement bonds almost completely disrupted, under low pressure, carbon dioxide atmospheres. The thermal conductivities of the cemented sample were approximately 3× higher, over the range of atmospheric pressures tested, than the thermal conductivities of the same sample after the cement bonds were broken. A thermal conductivity-derived particle size was determined for each sample by comparing these thermal conductivity measurements to previous data that demonstrated the dependence of thermal conductivity on particle size. Actual particle-size distributions were determined via physical separation through brass sieves. When uncemented, 87% of the particles were less than 125 μm in diameter, with 60% of the sample being less than 63 μm in diameter. As much as 35% of the cemented sample was composed of conglomerate particles with diameters greater than 500 μm. The thermal conductivities of the cemented sample were most similar to those of 500-μm glass beads, whereas the thermal conductivities of the uncemented sample were most similar to those of 75-μm glass beads. This study demonstrates that even a small amount of salt cement can significantly increase the thermal conductivity of particulate materials, as predicted by thermal modeling estimates by previous investigators.

  2. Investigation of in-flame soot optical properties in laminar coflow diffusion flames using thermophoretic particle sampling and spectral light extinction

    NASA Astrophysics Data System (ADS)

    Kempema, Nathan J.; Ma, Bin; Long, Marshall B.

    2016-09-01

    Soot optical properties are essential to the noninvasive study of the in-flame evolution of soot particles since they allow quantitative interpretation of optical diagnostics. Such experimental data are critical for comparison to results from computational models and soot sub-models. In this study, the thermophoretic sampling particle diagnostic (TSPD) technique is applied along with data from a previous spectrally resolved line-of-sight light attenuation experiment to determine the soot volume fraction and absorption function. The TSPD technique is applied in a flame stabilized on the Yale burner, and the soot scattering-to-absorption ratio is calculated using the Rayleigh-Debye-Gans theory for fractal aggregates and morphology information from a previous sampling experiment. The soot absorption function is determined as a function of wavelength and found to be in excellent agreement with previous in-flame measurements of the soot absorption function in coflow laminar diffusion flames. Two-dimensional maps of the soot dispersion exponent are calculated and show that the soot absorption function may have a positive or negative exponential wavelength dependence depending on the in-flame location. Finally, the wavelength dependence of the soot absorption function is related to the ratio of soot absorption functions, as would be found using two-excitation-wavelength laser-induced incandescence.

  3. Determinations of rare earth element abundance and U-Pb age of zircons using multispot laser ablation-inductively coupled plasma mass spectrometry.

    PubMed

    Yokoyama, Takaomi D; Suzuki, Toshihiro; Kon, Yoshiaki; Hirata, Takafumi

    2011-12-01

    We have developed a new calibration technique for multielement determination and U-Pb dating of zircon samples using laser ablation-inductively coupled plasma mass spectrometry (ICPMS) coupled with galvanometric optics. With the galvanometric optics, laser ablation of two or more sample materials could be achieved in very short time intervals (~10 ms). The resulting sample aerosols released from different ablation pits or different solid samples were mixed and homogenized within the sample cell and then transported into the ICP ion source. Multiple spot laser ablation enables spiking of analytes or internal standard elements directly into the solid samples, and therefore the standard addition calibration method can be applied for the determination of trace elements in solid samples. In this study, we have measured the rare earth element (REE) abundances of two zircon samples (Nancy 91500 and Prešovice) based on the standard addition technique, using a direct spiking of analytes through a multispot laser ablation of the glass standard material (NIST SRM612). The resulting REE abundance data show good agreement with previously reported values within analytical uncertainties achieved in this study (10% for most elements). Our experiments demonstrated that nonspectroscopic interferences on 14 REEs could be significantly reduced by the standard addition technique employed here. Another advantage of galvanometric devices is the accumulation of sample aerosol released from multiple spots. In this study we have measured the U-Pb age of a zircon sample (LMR) using an accumulation of sample aerosols released from 10 separate ablation pits of low diameters (~8 μm). The resulting (238)U-(206)Pb age data for the LMR zircons was 369 ± 64 Ma, which is in good agreement with previously reported age data (367.6 ± 1.5 Ma). (1) The data obtained here clearly demonstrate that the multiple spot laser ablation-ICPMS technique can become a powerful approach for elemental and isotopic ratio measurements in solid materials.

  4. A reevaluation of the Pallett Creek earthquake chronology based on new AMS radiocarbon dates, San Andreas fault, California

    NASA Astrophysics Data System (ADS)

    Scharer, Katherine M.; Biasi, Glenn P.; Weldon, Ray J., II

    2011-12-01

    The Pallett Creek paleoseismic record occupies a keystone position in most attempts to develop rupture histories for the southern San Andreas fault. Previous estimates of earthquake ages at Pallett Creek were determined by decay counting radiocarbon methods. That method requires large samples which can lead to unaccounted sources of uncertainty in radiocarbon ages because of the heterogeneous composition of organic layers. In contrast, accelerator mass spectrometry (AMS) radiocarbon dates may be obtained from small samples that have known carbon sources and also allow for a more complete sampling of the section. We present 65 new AMS radiocarbon dates that span nine ground-rupturing earthquakes at Pallett Creek. Overall, the AMS dates are similar to and reveal no dramatic bias in the conventional dates. For many layers, however, individual charcoal samples were younger than the conventional dates, leading to earthquake ages that are overall slightly younger than previously reported. New earthquake ages are determined by Bayesian refinement of the layer ages based on stratigraphic ordering and sedimentological constraints. The new chronology is more regular than previously published records in large part due to new samples constraining the age of event R. The closed interval from event C to 1857 has a mean recurrence of 135 years (σ = 83.2 years) and a quasiperiodic coefficient of variation (COV) of 0.61. We show that the new dates and resultant earthquake chronology have a stronger effect on COV than the specific membership of this long series and dating precision improvements from sedimentation rates.

  5. Exploring the Utilization of Low-Pressure, Piston-Cylinder Experiments to Determine the Bulk Compositions of Finite, Precious Materials

    NASA Astrophysics Data System (ADS)

    Vander Kaaden, K. E.; McCubbin, F. M.; Harrington, A.

    2017-12-01

    Determining the bulk composition of precious materials with a finite mass (e.g., meteorite samples) is extremely important in the fields of Earth and Planetary Science. From meteorite studies we are able to place constraints on large scale planetary processes like global differentiation and subsequent volcanism, as well as smaller scale processes like crystallization in a magma chamber or sedimentary compaction at the surface. However, with meteorite samples in particular, far too often we are limited by how precious the sample is as well as its limited mass. In this study, we have utilized aliquots of samples previously studied for toxicological hazards [1] including both the fresh samples (lunar mare basalt NWA 4734, lunar regolith breccia NWA 7611, martian basalt Tissint, martian regolith breccia NWA 7034, a vestian basalt Berthoud, a vestian regolith breccia NWA 2060, and a terrestrial mid-ocean ridge basalt (MORB)), and those that underwent iron leaching (Tissint, NWA 7034, NWA 4734, MORB). With these small masses of material, we performed low pressure ( 0.75 GPa), high temperature (>1600°C) melting experiments. Each sample was analyzed using a JEOL 8530F electron microprobe to determine the bulk composition of the materials that were previously examined in [1]. When available, the results of our microprobe data were compared with bulk rock compositions in the literature. The results of this study show that with this technique, only 50 mg of sample is required to accurately determine the bulk composition of the materials of interest. [1] Harrington, A.D., McCubbin, F.M., Kaur, J., Smirnov, A., Galdanes, K., Schoonen, M.A.A., Chen, L.C., Tsirka, S.E., and Gordon, T. (2017) Pulmonary inflammatory responses to acute meteroite dust exposures - Implications for human space exploration. 48th Lunar and Planetary Science Conference, The Woodlands, TX, #2922.

  6. Abundances of disk and bulge giants from high-resolution optical spectra. II. O, Mg, Ca, and Ti in the bulge sample

    NASA Astrophysics Data System (ADS)

    Jönsson, H.; Ryde, N.; Schultheis, M.; Zoccali, M.

    2017-02-01

    Context. Determining elemental abundances of bulge stars can, via chemical evolution modeling, help to understand the formation and evolution of the bulge. Recently there have been claims both for and against the bulge having a different [α/Fe] versus [Fe/H] trend as compared to the local thick disk. This could possibly indicate a faster, or at least different, formation timescale of the bulge as compared to the local thick disk. Aims: We aim to determine the abundances of oxygen, magnesium, calcium, and titanium in a sample of 46 bulge K giants, 35 of which have been analyzed for oxygen and magnesium in previous works, and compare this sample to homogeneously determined elemental abundances of a local disk sample of 291 K giants. Methods: We used spectral synthesis to determine both the stellar parameters and elemental abundances of the bulge stars analyzed here. We used the exact same method that we used to analyze the comparison sample of 291 local K giants in Paper I of this series. Results: Compared to the previous analysis of the 35 stars in our sample, we find lower [Mg/Fe] for [Fe/H] >-0.5, and therefore contradict the conclusion about a declining [O/Mg] for increasing [Fe/H]. We instead see a constant [O/Mg] over all the observed [Fe/H] in the bulge. Furthermore, we find no evidence for a different behavior of the alpha-iron trends in the bulge as compared to the local thick disk from our two samples. Note to the reader: following the publication of the corrigendum, the subtitle of the article was corrected on April 6, 2017. "O, Mg, Co, and Ti" has been replaced by "O, Mg, Ca, and Ti".Based on observations collected at the European Southern Observatory, Chile (ESO programs 71.B-0617(A), 073.B-0074(A), and 085.B-0552(A)).

  7. A study revealing the key aroma compounds of steamed bread made by Chinese traditional sourdough*

    PubMed Central

    Zhang, Guo-hua; Wu, Tao; Sadiq, Faizan A.; Yang, Huan-yi; Liu, Tong-jie; Ruan, Hui; He, Guo-qing

    2016-01-01

    Aroma of Chinese steamed bread (CSB) is one of the important parameters that determines the overall quality attributes and consumer acceptance. However, the aroma profile of CSB still remains poorly understood, mainly because of relying on only a single method for aroma extraction in previous studies. Therefore, the objective of this study was to determine the volatile aroma compounds of five different samples of CSB using three different aroma extraction methods, namely solid-phase microextraction (SPME), simultaneous distillation–extraction (SDE), and purge and trap (P&T). All samples showed a unique aroma profile, which could be attributed to their unique microbial consortia. (E)-2-Nonenal and (E,E)-2,4-decadienal were the most prevalent aromatic compounds revealed by SDE, which have not been reported previously, while ethanol and acetic acid proved to be the most dominant compounds by both SPME and P&T. Our approach of combining three different aroma extraction methods provided better insights into the aroma profile of CSB, which had remained largely unknown in previous studies. PMID:27704748

  8. The National Center on Indigenous Hawaiian Behavioral Health Study of Prevalence of Psychiatric Disorders in Native Hawaiian Adolescents

    ERIC Educational Resources Information Center

    Andrade, Naleen N.; Hishinuma, Earl S.; McDermott, John F., Jr.; Johnson, Ronald C.; Goebert, Deborah A.; Makini, George K., Jr.; Nahulu, Linda B.; Yuen, Noelle Y. C.; McArdle, John J.; Bell, Cathy K.; Carlton, Barry S.; Miyamoto, Robin H.; Nishimura, Stephanie T.; Else, Iwalani R. N.; Guerrero, Anthony P. S.; Darmal, Arsalan; Yates, Alayne; Waldron, Jane A.

    2006-01-01

    Objectives: The prevalence rates of disorders among a community-based sample of Hawaiian youths were determined and compared to previously published epidemiological studies. Method: Using a two-phase design, 7,317 adolescents were surveyed (60% participation rate), from which 619 were selected in a modified random sample during the 1992-1993 to…

  9. Surface buckling of black phosphorus: Determination, origin, and influence on electronic structure

    NASA Astrophysics Data System (ADS)

    Dai, Zhongwei; Jin, Wencan; Yu, Jie-Xiang; Grady, Maxwell; Sadowski, Jerzy T.; Kim, Young Duck; Hone, James; Dadap, Jerry I.; Zang, Jiadong; Osgood, Richard M.; Pohl, Karsten

    2017-12-01

    The surface structure of black phosphorus materials is determined using surface-sensitive dynamical microspot low energy electron diffraction (μ LEED ) analysis using a high spatial resolution low energy electron microscopy (LEEM) system. Samples of (i) crystalline cleaved black phosphorus (BP) at 300 K and (ii) exfoliated few-layer phosphorene (FLP) of about 10 nm thickness which were annealed at 573 K in vacuum were studied. In both samples, a significant surface buckling of 0.22 Å and 0.30 Å, respectively, is measured, which is one order of magnitude larger than previously reported. As direct evidence for large buckling, we observe a set of (for the flat surface forbidden) diffraction spots. Using first-principles calculations, we find that the presence of surface vacancies is responsible for the surface buckling in both BP and FLP, and is related to the intrinsic hole doping of phosphoresce materials previously reported.

  10. Surface buckling of black phosphorus: Determination, origin, and influence on electronic structure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dai, Zhongwei; Jin, Wencan; Yu, Jie-Xiang

    The surface structure of black phosphorus materials is determined using surface-sensitive dynamical microspot low energy electron diffraction ( μ LEED ) analysis using a high spatial resolution low energy electron microscopy (LEEM) system. Samples of (i) crystalline cleaved black phosphorus (BP) at 300 K and (ii) exfoliated few-layer phosphorene (FLP) of about 10 nm thickness which were annealed at 573 K in vacuum were studied. In both samples, a significant surface buckling of 0.22 Å and 0.30 Å, respectively, is measured, which is one order of magnitude larger than previously reported. As direct evidence for large buckling, we observe amore » set of (for the flat surface forbidden) diffraction spots. Using first-principles calculations, we find that the presence of surface vacancies is responsible for the surface buckling in both BP and FLP, and is related to the intrinsic hole doping of phosphoresce materials previously reported.« less

  11. Surface buckling of black phosphorus: Determination, origin, and influence on electronic structure

    DOE PAGES

    Dai, Zhongwei; Jin, Wencan; Yu, Jie-Xiang; ...

    2017-12-29

    The surface structure of black phosphorus materials is determined using surface-sensitive dynamical microspot low energy electron diffraction ( μ LEED ) analysis using a high spatial resolution low energy electron microscopy (LEEM) system. Samples of (i) crystalline cleaved black phosphorus (BP) at 300 K and (ii) exfoliated few-layer phosphorene (FLP) of about 10 nm thickness which were annealed at 573 K in vacuum were studied. In both samples, a significant surface buckling of 0.22 Å and 0.30 Å, respectively, is measured, which is one order of magnitude larger than previously reported. As direct evidence for large buckling, we observe amore » set of (for the flat surface forbidden) diffraction spots. Using first-principles calculations, we find that the presence of surface vacancies is responsible for the surface buckling in both BP and FLP, and is related to the intrinsic hole doping of phosphoresce materials previously reported.« less

  12. The Outer Solar System Origin Survey full data release orbit catalog and characterization.

    NASA Astrophysics Data System (ADS)

    Kavelaars, J. J.; Bannister, Michele T.; Gladman, Brett; Petit, Jean-Marc; Gwyn, Stephen; Alexandersen, Mike; Chen, Ying-Tung; Volk, Kathryn; OSSOS Collaboration.

    2017-10-01

    The Outer Solar System Origin Survey (OSSOS) completed main data acquisition in February 2017. Here we report the release of our full orbit sample, which include 836 TNOs with high precision orbit determination and classification. We combine the OSSOS orbit sample with previously release Canada-France Ecliptic Plane Survey (CFEPS) and a precursor survey to OSSOS by Alexandersen et al. to provide a sample of over 1100 TNO orbits with high precision classified orbits and precisely determined discovery and tracking circumstances (characterization). We are releasing the full sample and characterization to the world community, along with software for conducting ‘Survey Simulations’, so that this sample of orbits can be used to test models of the formation of our outer solar system against the observed sample. Here I will present the characteristics of the data set and present a parametric model for the structure of the classical Kuiper belt.

  13. Concentrations of the Allelochemical (+/-)-catechin IN Centaurea maculosa soils.

    PubMed

    Perry, Laura G; Thelen, Giles C; Ridenour, Wendy M; Callaway, Ragan M; Paschke, Mark W; Vivanco, Jorge M

    2007-12-01

    The phytotoxin (+/-)-catechin has been proposed to mediate invasion and autoinhibition by the Eurasian plant Centaurea maculosa (spotted knapweed). The importance of (+/-)-catechin to C. maculosa ecology depends in part on whether sufficient catechin concentrations occur at appropriate times and locations within C. maculosa soil to influence neighboring plants. Previous research on catechin in C. maculosa soils has yielded conflicting results, with some studies finding high soil catechin concentrations and other, more recent studies finding little or no catechin in field soils. Here, we report the most extensive study of soil catechin concentrations to date. We examined soil catechin concentrations in 402 samples from 11 C. maculosa sites in North America sampled in consecutive months over 1 yr, excluding winter months. One site was sampled on seven dates, another was sampled twice, and the remaining nine sites were each sampled once on a range of sampling dates. Methods used were similar to those with which we previously measured high soil catechin concentrations. We detected catechin only in the site that was sampled on seven dates and only on one sampling date in that site (May 16 2006), but in all samples collected on that date. The mean soil catechin concentration on that date was 0.65 +/- 0.45 (SD) mg g(-1), comparable to previously reported high concentrations. There are a number of possible explanations for the infrequency with which we detected soil catechin in this work compared to previous studies. Differences in results could reflect spatial and temporal variation in catechin exudation or degradation, as we examined different sites in a different year from most previous studies. Also, large quantities of catechin were detected in blanks for two sampling periods in the present study, leading us to discard those data. This contamination suggests that previous reports of high catechin concentrations that did not include blanks should be viewed with caution. Our results suggest that pure catechin is only rarely present in C. maculosa bulk soils. Thus, although catechin may play a role in C. maculosa invasion, the infrequency of soil catechin that we determined in this study suggests that we cannot be as certain of its role as previous reports of high soil catechin concentrations suggested.

  14. RECOMMENDATIONS FOR SAMPLING OF TANK 18 IN F TANK FARM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shine, G.

    2009-12-14

    Representative sampling is required for characterization of the residual floor material in Tank 18 prior to operational closure. Tank 18 is an 85-foot diameter, 34-foot high carbon steel tank with nominal operating volume of 1,300,000 gallons. It is a Type IV tank, and has been in service storing radioactive materials since 1959. Recent mechanical cleaning of the tank removed all mounds of material. Anticipating a low level of solids in the residual material, Huff and Thaxton [2009] developed a plan to sample the material during the final clean-up process while it would still be resident in sufficient quantities to supportmore » analytical determinations in four quadrants of the tank. Execution of the plan produced fewer solids than expected to support analytical determinations in all four quadrants. Huff and Thaxton [2009] then restructured the plan to characterize the residual floor material separately in the North and the South regions: two 'hemispheres.' This document provides sampling recommendations to complete the characterization of the residual material on the tank bottom following the guidance in Huff and Thaxton [2009] to split the tank floor into a North and a South hemisphere. The number of samples is determined from a modification of the formula previously published in Edwards [2001] and the sample characterization data for previous sampling of Tank 18 described by Oji [2009]. The uncertainty is quantified by an upper 95% confidence limit (UCL95%) on each analyte's mean concentration in Tank 18. The procedure computes the uncertainty in analyte concentration as a function of the number of samples, and the final number of samples is determined when the reduction in the uncertainty from an additional sample no longer has a practical impact on results. The characterization of the full suite of analytes in the North hemisphere is currently supported by a single Mantis rover sample obtained from a compact region near the center riser. A floor scrape sample was obtained from a compact region near the northeast riser and has been analyzed for a shortened list of key analytes. Since the unused portion of the floor scrape sample material is archived and available in sufficient quantity, additional analyses need to be performed to complete results for the full suite of constituents. The characterization of the full suite of analytes in the South hemisphere is currently supported by a single Mantis rover sample; there have been no floor scrape samples previously taken from the South hemisphere. The criterion to determine the number of additional samples was based on the practical reduction in the uncertainty when a new sample is added. This was achieved when five additional samples are obtained. In addition, two archived samples will be used if a contingency such as failing to demonstrate the comparability of the Mantis samples to the floor scrape samples occurs. To complete sampling of the Tank 18 residual floor material, three additional samples should be taken from the North hemisphere and four additional samples should be taken from the South hemisphere. One of the samples from each hemisphere will be archived in case of need. Two of the three additional samples from the North hemisphere and three of the four additional samples from the South hemisphere will be analyzed. Once the results are available, differences between the Mantis and three floor scrape samples (the sample previously obtained near NE riser plus the two additional samples that will be analyzed) results will be evaluated. If there are no statistically significant analyte concentration differences between the Mantis and floor scrape samples, those results will be combined and then UCL95%s will be calculated. If the analyte concentration differences between the Mantis and floor scrape samples are statistically significant, the UCL95%s will be calculated without the Mantis sample results. If further reduction in the upper confidence limits is needed and can be achieved by the addition of the archived samples, they will be analyzed and included in the statistical computations. Initially, the analyte concentrations in the residual material on the floor of Tank 18 will be determined separately in the North and the South hemispheres. However, if final sampling results show that differences between the North and South samples are consistent within sampling variation, then the final computations can be based on consolidating all sample results from the tank floor. Recommended locations may be subject to physical tank access and sampling constraints for the additional samples. The recommendations have been discussed in Section 4 and are based on partitioning the Tank 18 floor into an inner and an outer ring and six 60{sup o} sectors depicted in Figure 1. The location of the border between the inner and outer rings is based on dividing the residual material into two approximately equal volumes.« less

  15. Spectrophotometric determination of sulphate in automotive fuel ethanol by sequential injection analysis using dimethylsulphonazo(III) reaction.

    PubMed

    de Oliveira, Fabio Santos; Korn, Mauro

    2006-01-15

    A sensitive SIA method was developed for sulphate determination in automotive fuel ethanol. This method was based on the reaction of sulphate with barium-dimethylsulphonazo(III) leading to a decrease on the magnitude of analytical signal monitored at 665 nm. Alcohol fuel samples were previously burned up to avoid matrix effects for sulphate determinations. Binary sampling and stop-flow strategies were used to increase the sensitivity of the method. The optimization of analytical parameter was performed by response surface method using Box-Behnker and central composite designs. The proposed sequential flow procedure permits to determine up to 10.0mg SO(4)(2-)l(-1) with R.S.D. <2.5% and limit of detection of 0.27 mg l(-1). The method has been successfully applied for sulphate determination in automotive fuel alcohol and the results agreed with the reference volumetric method. In the optimized condition the SIA system carried out 27 samples per hour.

  16. Context-specific attentional sampling: Intentional control as a pre-requisite for contextual control.

    PubMed

    Brosowsky, Nicholaus P; Crump, Matthew J C

    2016-08-01

    Recent work suggests that environmental cues associated with previous attentional control settings can rapidly and involuntarily adjust attentional priorities. The current study tests predictions from adaptive-learning and memory-based theories of contextual control about the role of intentions for setting attentional priorities. To extend the empirical boundaries of contextual control phenomena, and to determine whether theoretical principles of contextual control are generalizable we used a novel bi-dimensional stimulus sampling task. Subjects viewed briefly presented arrays of letters and colors presented above or below fixation, and identified specific stimuli according to a dimensional (letter or color) and positional cue. Location was predictive of the cued dimension, but not the position or identity. In contrast to previous findings, contextual control failed to develop through automatic, adaptive-learning processes. Instead, previous experience with intentionally changing attentional sampling priorities between different contexts was required for contextual control to develop. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Quantitative surface topography determination by Nomarski reflection microscopy. 2: Microscope modification, calibration, and planar sample experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartman, J.S.; Gordon, R.L.; Lessor, D.L.

    1980-09-01

    The application of reflective Nomarski differential interference contrast microscopy for the determination of quantitative sample topography data is presented. The discussion includes a review of key theoretical results presented previously plus the experimental implementation of the concepts using a commercial Momarski microscope. The experimental work included the modification and characterization of a commercial microscope to allow its use for obtaining quantitative sample topography data. System usage for the measurement of slopes on flat planar samples is also discussed. The discussion has been designed to provide the theoretical basis, a physical insight, and a cookbook procedure for implementation to allow thesemore » results to be of value to both those interested in the microscope theory and its practical usage in the metallography laboratory.« less

  18. Rapid simultaneous determination of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, and 3,4-methylenedioxyethylamphetamine in urine by solid-phase extraction and GC-MS: a method optimized for high-volume laboratories.

    PubMed

    Stout, Peter R; Horn, Carl K; Klette, Kevin L

    2002-01-01

    To facilitate analysis of high sample volumes, an extraction, derivatization and gas chromatographic-mass spectrometric analysis method was developed to simultaneously determine amphetamine (AMP), methamphetamine (MAMP), 3,4-methylenedioxyamphetamine (MDA) 3,4-methylenedioxymethamphetamine (MDMA), and 3,4-methylenedioxyethylamphetamine (MDEA) in urine. This method utilized a positive-pressure manifold cation-exchange polymer-based solid-phase extraction followed by elution directly into automated liquid sampler (ALS) vials. Rapid derivatization was accomplished using heptafluorobutyric anhydride (HFBA). Recoveries averaged 90% or greater for each of the compounds. Limits of detection were 62.5 ng/mL (AMP and MDEA), 15.6 ng/mL (MAMP), and 31.3 ng/mL (MDA and MDMA) using a 2-mL sample volume. The method was linear to 5000 ng/mL for all compounds using MDMA-d5 and MAMP-d14 as internal standards. Over 200 human urine samples previously determined to contain the target analytes were analyzed using the method. Excellent agreement was seen with previous quantitations. The method was challenged with 75 potentially interfering compounds and no interferences were seen. These interfering compounds included ephedrine, pseudoephedrine, phenylpropanolamine, and phenethylamine. The method resulted in dramatic reductions in processing time and waste production.

  19. The frequency of previously undetectable deletions involving 3' Exons of the PMS2 gene.

    PubMed

    Vaughn, Cecily P; Baker, Christine L; Samowitz, Wade S; Swensen, Jeffrey J

    2013-01-01

    Lynch syndrome is characterized by mutations in one of four mismatch repair genes, MLH1, MSH2, MSH6, or PMS2. Clinical mutation analysis of these genes includes sequencing of exonic regions and deletion/duplication analysis. However, detection of deletions and duplications in PMS2 has previously been confined to Exons 1-11 due to gene conversion between PMS2 and the pseudogene PMS2CL in the remaining 3' exons (Exons 12-15). We have recently described an MLPA-based method that permits detection of deletions of PMS2 Exons 12-15; however, the frequency of such deletions has not yet been determined. To address this question, we tested for 3' deletions in 58 samples that were reported to be negative for PMS2 mutations using previously available methods. All samples were from individuals whose tumors exhibited loss of PMS2 immunohistochemical staining without concomitant loss of MLH1 immunostaining. We identified seven samples in this cohort with deletions in the 3' region of PMS2, including three previously reported samples with deletions of Exons 13-15 (two samples) and Exons 14-15. Also detected were deletions of Exons 12-15, Exon 13, and Exon 14 (two samples). Breakpoint analysis of the intragenic deletions suggests they occurred through Alu-mediated recombination. Our results indicate that ∼12% of samples suspected of harboring a PMS2 mutation based on immunohistochemical staining, for which mutations have not yet been identified, would benefit from testing using the new methodology. Copyright © 2012 Wiley Periodicals, Inc.

  20. Reexamining Sample Size Requirements for Multivariate, Abundance-Based Community Research: When Resources are Limited, the Research Does Not Have to Be.

    PubMed

    Forcino, Frank L; Leighton, Lindsey R; Twerdy, Pamela; Cahill, James F

    2015-01-01

    Community ecologists commonly perform multivariate techniques (e.g., ordination, cluster analysis) to assess patterns and gradients of taxonomic variation. A critical requirement for a meaningful statistical analysis is accurate information on the taxa found within an ecological sample. However, oversampling (too many individuals counted per sample) also comes at a cost, particularly for ecological systems in which identification and quantification is substantially more resource consuming than the field expedition itself. In such systems, an increasingly larger sample size will eventually result in diminishing returns in improving any pattern or gradient revealed by the data, but will also lead to continually increasing costs. Here, we examine 396 datasets: 44 previously published and 352 created datasets. Using meta-analytic and simulation-based approaches, the research within the present paper seeks (1) to determine minimal sample sizes required to produce robust multivariate statistical results when conducting abundance-based, community ecology research. Furthermore, we seek (2) to determine the dataset parameters (i.e., evenness, number of taxa, number of samples) that require larger sample sizes, regardless of resource availability. We found that in the 44 previously published and the 220 created datasets with randomly chosen abundances, a conservative estimate of a sample size of 58 produced the same multivariate results as all larger sample sizes. However, this minimal number varies as a function of evenness, where increased evenness resulted in increased minimal sample sizes. Sample sizes as small as 58 individuals are sufficient for a broad range of multivariate abundance-based research. In cases when resource availability is the limiting factor for conducting a project (e.g., small university, time to conduct the research project), statistically viable results can still be obtained with less of an investment.

  1. pH matters: The influence of the catalyst ink on the oxygen reduction activity determined in thin film rotating disk electrode measurements

    NASA Astrophysics Data System (ADS)

    Inaba, Masanori; Quinson, Jonathan; Arenz, Matthias

    2017-06-01

    We investigated the influence of the ink properties of proton exchange membrane fuel cell (PEMFC) catalysts on the oxygen reduction reaction (ORR) activity determined in thin film rotating disk electrode (TF-RDE) measurements. It was found that the adaption of a previously reported ink recipe to home-made catalysts does not lead to satisfying results, although reported work could be reproduced using commercial catalyst samples. It is demonstrated that the pH of the catalyst ink, which has not been addressed in previous TF-RDE studies, is an important parameter that needs to be carefully controlled to determine the intrinsic ORR activity of high surface area catalysts.

  2. Binary Colloidal Alloy Test-5: Three-Dimensional Melt

    NASA Technical Reports Server (NTRS)

    Yodh, Arjun G.

    2008-01-01

    Binary Colloidal Alloy Test - 5: Three-Dimensional Melt (BCAT-5-3DMelt) photographs initially randomized colloidal samples in microgravity to determine their resulting structure over time. BCAT-5-3D-Melt will allow the scientists to capture the kinetics (evolution) of their samples, as well as the final equilibrium state of each sample. BCAT-5-3D-Melt will look at the mechanisms of melting using three-dimensional temperature sensitive colloidal crystals. Results will help scientists develop fundamental physics concepts previously shadowed by the effects of gravity.

  3. Determination of 60Co activity in steel samples in Hiroshima.

    PubMed

    Hamada, T

    1991-03-01

    Specific activity of 60C in two steel samples taken at 687m S and 1295m NNW from the hypocenter was measured by gamma-ray spectrometry and neutron activation analysis. The results are consistent with previous data by Hashizume et al. for steel rings on the surface of roofs of buildings. content of nickel and copper in the samples was found to be too small to account for any significant 60Co production by fast neutron reactions.

  4. Extending the solvent-free MALDI sample preparation method.

    PubMed

    Hanton, Scott D; Parees, David M

    2005-01-01

    Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is an important technique to characterize many different materials, including synthetic polymers. MALDI mass spectral data can be used to determine the polymer average molecular weights, repeat units, and end groups. One of the key issues in traditional MALDI sample preparation is making good solutions of the analyte and the matrix. Solvent-free sample preparation methods have been developed to address these issues. Previous results of solvent-free or dry prepared samples show some advantages over traditional wet sample preparation methods. Although the results of the published solvent-free sample preparation methods produced excellent mass spectra, we found the method to be very time-consuming, with significant tool cleaning, which presents a significant possibility of cross contamination. To address these issues, we developed an extension of the solvent-free method that replaces the mortar and pestle grinding with ball milling the sample in a glass vial with two small steel balls. This new method generates mass spectra with equal quality of the previous methods, but has significant advantages in productivity, eliminates cross contamination, and is applicable to liquid and soft or waxy analytes.

  5. In search of ancient biomarkers: Using femtosecond - Laser Desorption Post Ionization - Mass Spectrometry (fs-LDPI-MS) to map organic compounds within ca. 2.7 Ga samples from the Abitibi greenstone belt, Ontario, Canada

    NASA Astrophysics Data System (ADS)

    Pasterski, M. J.; Barry, G.; Hanley, L.; Kenig, F. P. H.

    2016-12-01

    One of the major challenges within the field of organic geochemistry is to determine whether an observed biomarker signature was emplaced during sedimentation (indigenous), after sedimentation via the post-depositional migration of fluids (non-indigenous), or during sampling, storage, or analysis (contaminant). Current geochemical techniques (e.g. gas chromatography-mass spectrometry, GC-MS and GCxGC-MS) can effectively determine the composition and structure of the organic constituents of a sample. However, because of the multiple preparatory steps necessary prior to GC-MS analysis (sample crushing, solvent extraction, organic fraction separation) it is impossible to precisely determine the spatial relationship between the host sample and the organic molecules within. We used an MS imaging method developed by Prof. Luke Hanley at the University of Illinois at Chicago, femtosecond-laser desorption post ionization-MS (fs-LDPI-MS), to map the organics within previously characterized ca.2.7 billion year old (Ga) metasediments from the Abitibi greenstone belt near Timmins, ON, Canada. We then compared the MS images to petrographic observations that displayed the distribution of mineral species with well constrained mineralization ages as well as fluid inclusions within the samples. Fluid inclusions are formed during mineralization and have the ability to remain intact over long timescales (up to billions of years), protecting the fluids inside from the introduction of non-indigenous and contaminant biomarkers. Although migrating post-depositional fluids can remineralize sediments, fluid inclusions associated with secondary additions are focused along grain boundaries and microfractures (secondary inclusions), thus, inclusions which are located within grain boundaries can be considered primary and the age of their formation can be determined relative to the host rock. Preliminary results indicate that previously observed biomarkers may be linked to a series of hydrothermal events which occurred regionally ca. 2.64 Ga.

  6. Determinants of change in polypharmacy status in Switzerland: the population-based CoLaus study.

    PubMed

    Abolhassani, Nazanin; Castioni, Julien; Marques-Vidal, Pedro; Vollenweider, Peter; Waeber, Gérard

    2017-09-01

    This study aimed to assess the prevalence, the change, and the determinants of change in polypharmacy in a population-based sample. Baseline (2003-2006) and follow-up (2009-2012) data are from 4679 participants aged between 35 and 75 years (53.5% women, mean age 52.6 ± 10.6 years) from the population of Lausanne, Switzerland. Polypharmacy was defined by the regular use of ≥5 drugs. Four categories of change were defined: never (no polypharmacy at baseline and follow-up), initiating (no polypharmacy at baseline but at follow-up), maintaining, or quitting. Polypharmacy increased from 7.7% at baseline to 15.3% at follow-up. Cardiovascular drugs were the most prescribed medicines at baseline and follow-up. Gender, age, obesity, smoking, previously diagnosed hypertension, or diabetes or dyslipidemia were significantly and independently associated with initiating and maintaining polypharmacy. In a population-based sample, prevalence of polypharmacy doubled over a 5.6-year period. The main determinants of initiating polypharmacy were age, overweight and obesity, smoking status, and previously diagnosed cardiovascular risk factors.

  7. Evaluation of two 4th generation point-of-care assays for the detection of Human Immunodeficiency Virus infection.

    PubMed

    Stafylis, Chrysovalantis; Klausner, Jeffrey D

    2017-01-01

    Fourth generation assays detect simultaneously antibodies for HIV and the p24 antigen, identifying HIV infection earlier than previous generation tests. Previous studies have shown that the Alere Determine HIV-1/2 Combo has lower than anticipated performance in detecting antibodies for HIV and the p24 antigen. Furthermore, there are currently very few studies evaluating the performance of Standard Diagnostics BIOLINE HIV Ag/Ab Combo. To evaluate the performance of the Alere Determine HIV-1/2 Combo and the Standard Diagnostics BIOLINE HIV Ag/Ab Combo in a panel of frozen serum samples. The testing panel included 133 previously frozen serum specimens from the UCLA Clinical Microbiology & Immunoserology laboratory. Reference testing included testing for HIV antibodies by a 3rd generation enzyme immunoassay followed by HIV RNA detection. Antibody negative and RNA positive sera were also tested by a laboratory 4th generation HIV Ab/Ag enzyme immunoassay. Reference testing yielded 97 positives for HIV infection and 36 negative samples. Sensitivity of the Alere test was 95% (88-98%), while the SD Bioline sensitivity was 91% (83-96%). Both assays showed 100% (90-100%) specificity. No indeterminate or invalid results were recorded. Among 13 samples with acute infection (HIV RNA positive, HIV antibody negative), 12 were found positive by the first assay and 8 by the second. The antigen component of the Alere assay detected 10 acute samples, while the SD Bioline assay detected only one. Both rapid assays showed very good overall performance in detecting HIV infection in frozen serum samples, but further improvements are required to improve the performance in acute infection.

  8. A simplified method for determining heat of combustion of natural gas

    NASA Technical Reports Server (NTRS)

    Singh, Jag J.; Chegini, Hoshang; Mall, Gerald H.

    1987-01-01

    A simplified technique for determination of the heat of combustion of natural gas has been developed. It is a variation of the previously developed technique wherein the carrier air, in which the test sample was burnt, was oxygen enriched to adjust the mole fraction of oxygen in the combustion product gases up to that in the carrier air. The new technique eliminates the need for oxygen enrichment of the experimental mixtures and natural gas samples and has been found to predict their heats of combustion to an uncertainty of the order of 1 percent.

  9. High pressure liquid chromatographic determination of aflatoxins in spices.

    PubMed

    Awe, M J; Schranz, J L

    1981-11-01

    High pressure liquid chromatography with fluorescence detection is used to determine aflatoxin in 5 common spices. A 10 micrometer microparticulate silica gel column is used with a dichloromethane-cyclohexane-acetonitrile solvent system to resolve aflatoxins B1, G1, B2, and G2. The fluorescence detector contained a silica gel-packed flowcell. Samples of black, white, and red pepper, ginger, and nutmeg were extracted according to a previously published method. Recoveries from aflatoxin-free samples of white pepper, ginger, and red pepper spiked with 1-50 micrograms aflatoxin/kg ranged from 64 to 92%.

  10. Application of New Partition Coefficients to Modeling Plagioclase

    NASA Technical Reports Server (NTRS)

    Fagan, A. L.; Neal, C. R.; Rapp, J. F.; Draper, D. S.; Lapen, T. J.

    2017-01-01

    Previously, studies that determined the partition coefficient for an element, i, between plagioclase and the residual basaltic melt (Di plag) have been conducted using experimental conditions dissimilar from the Moon, and thus these values are not ideal for modeling plagioclase fractionation in a lunar system. However, recent work [1] has determined partition coefficients for plagioclase at lunar oxygen fugacities, and resulted in plagioclase with Anorthite contents =An90; these are significantly more calcic than plagioclase in previous studies, and the An content has a profound effect on partition coefficient values [2,3]. Plagioclase D-values, which are dependent on the An content of the crystal [e.g., 2-6], can be determined using published experimental data and the correlative An contents. Here, we examine new experimental data from [1] to ascertain their effect on the calculation of equilibrium liquids from Apollo 16 sample 60635,2. This sample is a coarse grained, subophitic impact melt composed of 55% plagioclase laths with An94.4-98.7 [7,8], distinctly more calcic than of previous partition coefficient studies (e.g., [3-6, 9-10]). Sample 60635,2 is notable as having several plagioclase trace element analyses containing a negative Europium anomaly (-Eu) in the rare-earth element (REE) profile, rather than the typical positive Eu anomaly (+Eu) [7-8] (Fig. 1). The expected +Eu is due to the similarity in size and charge with Ca2+, thereby allowing Eu2+ to be easily taken up by the plagioclase crystal structure, in contrast to the remaining REE3+. Some 60635,2 plagioclase crystals only have +Eu REE profiles, some only have -Eu REE profiles, and some +Eu and -Eu analyses in different areas on a single crystal [7, 8]. Moreover, there does not seem to be any core-rim association with the +Eu or -Eu analyses, nor does there appear to be a correlation between the size, shape, or location of a particular crystal within the sample and the sign of its Eu anomaly, which suggests a complex evolution. In order to investigate this sample further, we can calculate the equilibrium liquids, but with An contents distinct from previous experimental studies, we must calculate the appropriate partition coefficients for each trace element analysis.

  11. Recalibration of the M {sub BH}– σ {sub ⋆} Relation for AGN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Batiste, Merida; Bentz, Misty C.; Raimundo, Sandra I.

    2017-03-20

    We present a recalibration of the M {sub BH}– σ {sub ⋆} relation, based on a sample of 16 reverberation-mapped galaxies with newly determined bulge stellar velocity dispersions ( σ {sub ⋆}) from integral-field spectroscopy (IFS), and a sample of 32 quiescent galaxies with publicly available IFS. For both samples, σ {sub ⋆} is determined via two different methods that are popular in the literature, and we provide fits for each sample based on both sets of σ {sub ⋆}. We find the fit to the active galactic nucleus sample is shallower than the fit to the quiescent galaxy sample,more » and that the slopes for each sample are in agreement with previous investigations. However, the intercepts to the quiescent galaxy relations are notably higher than those found in previous studies, due to the systematically lower σ {sub ⋆} measurements that we obtain from IFS. We find that this may be driven, in part, by poorly constrained measurements of bulge effective radius ( r{sub e}) for the quiescent galaxy sample, which may bias the σ {sub ⋆} measurements low. We use these quiescent galaxy parameterizations, as well as one from the literature, to recalculate the virial scaling factor f . We assess the potential biases in each measurement, and suggest f = 4.82 ± 1.67 as the best currently available estimate. However, we caution that the details of how σ {sub ⋆} is measured can significantly affect f , and there is still much room for improvement.« less

  12. Geochemical constraints on the half-life of {sup 130}Te

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, H. V.; Pattrick, R. A. D.; Crowther, S. A.

    2008-11-15

    To determine the half-life of {sup 130}Te we have analyzed multiple aliquots of geological telluride samples 100 times smaller than those previously reported using a unique resonance ionization mass spectrometer. We employ a low-fluence neutron irradiation that allows determination of parent and daughter from the same xenon isotopic analysis. Step heating of these irradiated samples allows the {sup 130}Xe/{sup 132}Xe ratio of fluids trapped inside the tellurides to be determined. Considering only samples where the trapped {sup 130}Xe/{sup 132}Xe ratio is demonstrably consistent with atmospheric xenon, we can avoid over- or under-estimating the half-life due to redistribution or inheritance ofmore » radiogenic {sup 130}Xe. Combining our work with literature data, it is clear that several relatively young samples have retained xenon quantitatively since formation, allowing the half-life to be determined as (8.0{+-}1.1)x10{sup 20} yr. Older samples have clearly been affected by post-formation processing. This suggests that there is little hope of monitoring solar luminosity through the geological record of {sup 126}Xe production by solar neutrinos, but it is possible that geologically useful chronological information can be obtained from this system.« less

  13. Data analysis considerations for pesticides determined by National Water Quality Laboratory schedule 2437

    USGS Publications Warehouse

    Shoda, Megan E.; Nowell, Lisa H.; Stone, Wesley W.; Sandstrom, Mark W.; Bexfield, Laura M.

    2018-04-02

    In 2013, the U.S. Geological Survey National Water Quality Laboratory (NWQL) made a new method available for the analysis of pesticides in filtered water samples: laboratory schedule 2437. Schedule 2437 is an improvement on previous analytical methods because it determines the concentrations of 225 fungicides, herbicides, insecticides, and associated degradates in one method at similar or lower concentrations than previously available methods. Additionally, the pesticides included in schedule 2437 were strategically identified in a prioritization analysis that assessed likelihood of occurrence, prevalence of use, and potential toxicity. When the NWQL reports pesticide concentrations for analytes in schedule 2437, the laboratory also provides supplemental information useful to data users for assessing method performance and understanding data quality. That supplemental information is discussed in this report, along with an initial analysis of analytical recovery of pesticides in water-quality samples analyzed by schedule 2437 during 2013–2015. A total of 523 field matrix spike samples and their paired environmental samples and 277 laboratory reagent spike samples were analyzed for this report (1,323 samples total). These samples were collected in the field as part of the U.S. Geological Survey National Water-Quality Assessment groundwater and surface-water studies and as part of the NWQL quality-control program. This report reviews how pesticide samples are processed by the NWQL, addresses how to obtain all the data necessary to interpret pesticide concentrations, explains the circumstances that result in a reporting level change or the occurrence of a raised reporting level, and describes the calculation and assessment of recovery. This report also discusses reasons why a data user might choose to exclude data in an interpretive analysis and outlines the approach used to identify the potential for decreased data quality in the assessment of method recovery. The information provided in this report is essential to understanding pesticide data determined by schedule 2437 and should be reviewed before interpretation of these data.

  14. OPTICAL–NEAR-INFRARED PHOTOMETRIC CALIBRATION OF M DWARF METALLICITY AND ITS APPLICATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hejazi, N.; Robertis, M. M. De; Dawson, P. C., E-mail: nedahej@yorku.ca, E-mail: mmdr@yorku.ca, E-mail: pdawson@trentu.ca

    2015-04-15

    Based on a carefully constructed sample of dwarf stars, a new optical–near-infrared photometric calibration to estimate the metallicity of late-type K and early-to-mid-type M dwarfs is presented. The calibration sample has two parts; the first part includes 18 M dwarfs with metallicities determined by high-resolution spectroscopy and the second part contains 49 dwarfs with metallicities obtained through moderate-resolution spectra. By applying this calibration to a large sample of around 1.3 million M dwarfs from the Sloan Digital Sky Survey and 2MASS, the metallicity distribution of this sample is determined and compared with those of previous studies. Using photometric parallaxes, themore » Galactic heights of M dwarfs in the large sample are also estimated. Our results show that stars farther from the Galactic plane, on average, have lower metallicity, which can be attributed to the age–metallicity relation. A scarcity of metal-poor dwarf stars in the metallicity distribution relative to the Simple Closed Box Model indicates the existence of the “M dwarf problem,” similar to the previously known G and K dwarf problems. Several more complicated Galactic chemical evolution models which have been proposed to resolve the G and K dwarf problems are tested and it is shown that these models could, to some extent, mitigate the M dwarf problem as well.« less

  15. The Sex Determination Gene Shows No Founder Effect in the Giant Honey Bee, Apis dorsata

    PubMed Central

    Yan, Wei Yu; Wu, Xiao Bo; Zeng, Zhi Jiang; Huang, Zachary Y.

    2012-01-01

    Background All honey bee species (Apis spp) share the same sex determination mechanism using the complementary sex determination (csd) gene. Only individuals heterogeneous at the csd allele develop into females, and the homozygous develop into diploid males, which do not survive. The honeybees are therefore under selection pressure to generate new csd alleles. Previous studies have shown that the csd gene is under balancing selection. We hypothesize that due to the long separation from the mainland of Hainan Island, China, that the giant honey bees (Apis dorsata) should show a founder effect for the csd gene, with many different alleles clustered together, and these would be absent on the mainland. Methodology/Principal Findings We sampled A. dorsata workers from both Hainan and Guangxi Provinces and then cloned and sequenced region 3 of the csd gene and constructed phylogenetic trees. We failed to find any clustering of the csd alleles according to their geographical origin, i.e. the Hainan and Guangxi samples did not form separate clades. Further analysis by including previously published csd sequences also failed to show any clade-forming in both the Philippines and Malaysia. Conclusions/Significance Results from this study and those from previous studies did not support the expectations of a founder effect. We conclude that because of the extremely high mating frequency of A. dorsata queens, a founder effect does not apply in this species. PMID:22511940

  16. The sex determination gene shows no founder effect in the giant honey bee, Apis dorsata.

    PubMed

    Liu, Zhi Yong; Wang, Zi Long; Yan, Wei Yu; Wu, Xiao Bo; Zeng, Zhi Jiang; Huang, Zachary Y

    2012-01-01

    All honey bee species (Apis spp) share the same sex determination mechanism using the complementary sex determination (csd) gene. Only individuals heterogeneous at the csd allele develop into females, and the homozygous develop into diploid males, which do not survive. The honeybees are therefore under selection pressure to generate new csd alleles. Previous studies have shown that the csd gene is under balancing selection. We hypothesize that due to the long separation from the mainland of Hainan Island, China, that the giant honey bees (Apis dorsata) should show a founder effect for the csd gene, with many different alleles clustered together, and these would be absent on the mainland. We sampled A. dorsata workers from both Hainan and Guangxi Provinces and then cloned and sequenced region 3 of the csd gene and constructed phylogenetic trees. We failed to find any clustering of the csd alleles according to their geographical origin, i.e. the Hainan and Guangxi samples did not form separate clades. Further analysis by including previously published csd sequences also failed to show any clade-forming in both the Philippines and Malaysia. Results from this study and those from previous studies did not support the expectations of a founder effect. We conclude that because of the extremely high mating frequency of A. dorsata queens, a founder effect does not apply in this species.

  17. Capillary whole blood testing by a new portable monitor. Comparison with standard determination of the international normalized ratio.

    PubMed

    de Miguel, Dunia; Burgaleta, Carmen; Reyes, Eduardo; Pascual, Teresa

    2003-07-01

    We evaluated a new portable monitor (AvoSure PT PRO, Menarini Diagnostics, Firenze, Italy) developed to test the prothrombin time in capillary blood and plasma by comparing it with the standard laboratory determination. We studied 62 patients receiving acenocoumarol therapy. The international normalized ratio (INR) in capillary blood was analyzed by 2 methods: AvoSure PT PRO and Thrombotrack Nycomed Analyzer (Axis-Shield, Dundee, Scotland). Parallel studies were performed in plasma samples by a reference method using the Behring Coagulation Timer (Behring Diagnostics, Marburg, Germany). Plasma samples also were tested with the AvoSure PT PRO. Correlation was good for INR values for capillary blood and plasma samples by AvoSure PT PRO and our reference method (R2 = 0.8596) and for capillary blood samples tested by the AvoSure PT PRO and Thrombotrack Nycomed Analyzer (R2 = 0.8875). The correlation for INR in capillary blood and plasma samples by AvoSure PT PRO was 0.6939 (P < .0004). Capillary blood determinations are rapid and effective for monitoring oral anticoagulation therapy and have a high correlation to plasma determinations. AvoSure PT PRO is accurate for controlling INR in plasma and capillary blood samples, may be used in outpatient clinics, and has advantages over previous portable monitors.

  18. Isolating Viral and Host RNA Sequences from Archival Material and Production of cDNA Libraries for High-Throughput DNA Sequencing

    PubMed Central

    Xiao, Yongli; Sheng, Zong-Mei; Taubenberger, Jeffery K.

    2015-01-01

    The vast majority of surgical biopsy and post-mortem tissue samples are formalin-fixed and paraffin-embedded (FFPE), but this process leads to RNA degradation that limits gene expression analysis. As an example, the viral RNA genome of the 1918 pandemic influenza A virus was previously determined in a 9-year effort by overlapping RT-PCR from post-mortem samples. Using the protocols described here, the full genome of the 1918 virus at high coverage was determined in one high-throughput sequencing run of a cDNA library derived from total RNA of a 1918 FFPE sample after duplex-specific nuclease treatments. This basic methodological approach should assist in the analysis of FFPE tissue samples isolated over the past century from a variety of infectious diseases. PMID:26344216

  19. Scale-up of an ultrasound-enhanced bioscouring process

    USDA-ARS?s Scientific Manuscript database

    Using previously determined optimized reaction conditions, an ultrasound-enhanced bioscouring process was scaled to ten gallon capacity and a system of rollers was added which allowed for continuous fabric feed and equipment operation. UV-Vis photospectroscopic data from bioscoured fabric samples co...

  20. Understanding Cultivar-Specificity and Soil Determinants of the Cannabis Microbiome

    DOE PAGES

    Winston, Max E.; Hampton-Marcell, Jarrad; Zarraonaindia, Iratxe; ...

    2014-06-16

    Understanding microbial partnerships with the medicinally and economically important crop Cannabis has the potential to affect agricultural practice by improving plant fitness and production yield. Furthermore, Cannabis presents an interesting model to explore plant-microbiome interactions as it produces numerous secondary metabolic compounds. Here we present the first description of the endorhiza-, rhizosphere-, and bulk soil-associated microbiome of five distinct Cannabis cultivars. Bacterial communities of the endorhiza showed significant cultivar-specificity. When controlling cultivar and soil type the microbial community structure was significantly different between plant cultivars, soil types, and between the endorhiza, rhizosphere and soil. In conclusion, the influence of soilmore » type, plant cultivar and sample type differentiation on the microbial community structure provides support for a previously published two-tier selection model, whereby community composition across sample types is determined mainly by soil type, while community structure within endorhiza samples is determined mainly by host cultivar.« less

  1. Understanding Cultivar-Specificity and Soil Determinants of the Cannabis Microbiome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winston, Max E.; Hampton-Marcell, Jarrad; Zarraonaindia, Iratxe

    Understanding microbial partnerships with the medicinally and economically important crop Cannabis has the potential to affect agricultural practice by improving plant fitness and production yield. Furthermore, Cannabis presents an interesting model to explore plant-microbiome interactions as it produces numerous secondary metabolic compounds. Here we present the first description of the endorhiza-, rhizosphere-, and bulk soil-associated microbiome of five distinct Cannabis cultivars. Bacterial communities of the endorhiza showed significant cultivar-specificity. When controlling cultivar and soil type the microbial community structure was significantly different between plant cultivars, soil types, and between the endorhiza, rhizosphere and soil. In conclusion, the influence of soilmore » type, plant cultivar and sample type differentiation on the microbial community structure provides support for a previously published two-tier selection model, whereby community composition across sample types is determined mainly by soil type, while community structure within endorhiza samples is determined mainly by host cultivar.« less

  2. Probing the microscopic environment of 23 Na ions in brain tissue by MRI: On the accuracy of different sampling schemes for the determination of rapid, biexponential T2* decay at low signal-to-noise ratio.

    PubMed

    Lommen, Jonathan M; Flassbeck, Sebastian; Behl, Nicolas G R; Niesporek, Sebastian; Bachert, Peter; Ladd, Mark E; Nagel, Armin M

    2018-08-01

    To investigate and to reduce influences on the determination of the short and long apparent transverse relaxation times ( T2,s*, T2,l*) of 23 Na in vivo with respect to signal sampling. The accuracy of T2* determination was analyzed in simulations for five different sampling schemes. The influence of noise in the parameter fit was investigated for three different models. A dedicated sampling scheme was developed for brain parenchyma by numerically optimizing the parameter estimation. This scheme was compared in vivo to linear sampling at 7T. For the considered sampling schemes, T2,s* / T2,l* exhibit an average bias of 3% / 4% with a variation of 25% / 15% based on simulations with previously published T2* values. The accuracy could be improved with the optimized sampling scheme by strongly averaging the earliest sample. A fitting model with constant noise floor can increase accuracy while additional fitting of a noise term is only beneficial in case of sampling until late echo time > 80 ms. T2* values in white matter were determined to be T2,s* = 5.1 ± 0.8 / 4.2 ± 0.4 ms and T2,l* = 35.7 ± 2.4 / 34.4 ± 1.5 ms using linear/optimized sampling. Voxel-wise T2* determination of 23 Na is feasible in vivo. However, sampling and fitting methods have to be chosen carefully to retrieve accurate results. Magn Reson Med 80:571-584, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  3. Modelling the stochastic nature of the available coefficient of friction at footwear-floor interfaces.

    PubMed

    Gragg, Jared; Klose, Ellison; Yang, James

    2017-07-01

    The available coefficient of friction (ACOF) is a measure of the friction available between two surfaces, which for human gait would be the footwear-floor interface. It is often compared to the required coefficient of friction (RCOF) to determine the likelihood of a slip in gait. Both the ACOF and RCOF are stochastic by nature meaning that neither should be represented by a deterministic value, such as the sample mean. Previous research has determined that the RCOF can be modelled well by either the normal or lognormal distributions, but previous research aimed at determining an appropriate distribution for the ACOF was inconclusive. This study focuses on modelling the stochastic nature of the ACOF by fitting eight continuous probability distributions to ACOF data for six scenarios. In addition, the data were used to study the effect that a simple housekeeping action such as sweeping could have on the ACOF. Practitioner Summary: Previous research aimed at determining an appropriate distribution for the ACOF was inconclusive. The study addresses this issue as well as looking at the effect that an act such as sweeping has on the ACOF.

  4. Subjective wellbeing and income: Empirical patterns in the rural developing world.

    PubMed

    Reyes-García, Victoria; Babigumira, Ronnie; Pyhälä, Aili; Wunder, Sven; Zorondo-Rodríguez, Francisco; Angelsen, Arild

    2016-04-01

    A commonality in the economics of happiness literature is that absolute income matters more for the subjective wellbeing of people at low income levels. In this article, we use a large sample of people in rural areas of developing countries with relatively low income levels to test whether subjective wellbeing an increasing function of absolute income in our sample, and to analyze the existence of adaptation and social comparison effects on subjective wellbeing. Our sample includes 6973 rural households in 23 countries throughout Asia, Africa, and Latin America. The average total income per adult equivalent in our sample was US$1555, whereas levels of subjective wellbeing resembled levels found in previous research using cross-country data. We find that, despite low levels of absolute income, levels of subjective wellbeing of our respondents resemble levels found in previous research using cross-country data. We also find remarkable similarities in many of the determinants of subjective wellbeing previously tested. Our data show that absolute income covariates with subjective wellbeing, but -as for richer samples- the magnitude of the association is lower once we control for adaptation and social comparison. Finally, our results suggest that social comparison has a stronger effect than adaptation in explaining the subjective wellbeing of our sample. Our findings highlight the importance of adaptation and social comparison even at low levels of absolute income.

  5. Subjective wellbeing and income: Empirical patterns in the rural developing world

    PubMed Central

    Reyes-García, Victoria; Babigumira, Ronnie; Pyhälä, Aili; Wunder, Sven; Zorondo-Rodríguez, Francisco; Angelsen, Arild

    2016-01-01

    A commonality in the economics of happiness literature is that absolute income matters more for the subjective wellbeing of people at low income levels. In this article, we use a large sample of people in rural areas of developing countries with relatively low income levels to test whether subjective wellbeing an increasing function of absolute income in our sample, and to analyze the existence of adaptation and social comparison effects on subjective wellbeing. Our sample includes 6973 rural households in 23 countries throughout Asia, Africa, and Latin America. The average total income per adult equivalent in our sample was US$1555, whereas levels of subjective wellbeing resembled levels found in previous research using cross-country data. We find that, despite low levels of absolute income, levels of subjective wellbeing of our respondents resemble levels found in previous research using cross-country data. We also find remarkable similarities in many of the determinants of subjective wellbeing previously tested. Our data show that absolute income covariates with subjective wellbeing, but -as for richer samples- the magnitude of the association is lower once we control for adaptation and social comparison. Finally, our results suggest that social comparison has a stronger effect than adaptation in explaining the subjective wellbeing of our sample. Our findings highlight the importance of adaptation and social comparison even at low levels of absolute income. PMID:27642259

  6. Electrospray ionization and time-of-flight mass spectrometric method for simultaneous determination of spermidine and spermine.

    PubMed

    Samejima, Keijiro; Otani, Masahiro; Murakami, Yasuko; Oka, Takami; Kasai, Misao; Tsumoto, Hiroki; Kohda, Kohfuku

    2007-10-01

    A sensitive method for the determination of polyamines in mammalian cells was described using electrospray ionization and time-of-flight mass spectrometer. This method was 50-fold more sensitive than the previous method using ionspray ionization and quadrupole mass spectrometer. The method employed the partial purification and derivatization of polyamines, but allowed a measurement of multiple samples which contained picomol amounts of polyamines. Time required for data acquisition of one sample was approximately 2 min. The method was successfully applied for the determination of reduced spermidine and spermine contents in cultured cells under the inhibition of aminopropyltransferases. In addition, a new proper internal standard was proposed for the tracer experiment using (15)N-labeled polyamines.

  7. SPME-GC-pyrolysis-AFS determination of methylmercury in marine fish products by alkaline sample preparation and aqueous phase phenylation derivatization.

    PubMed

    Jókai, Zsuzsa; Abrankó, László; Fodor, Péter

    2005-07-13

    Characterization of a cost-efficient analytical method based on alkaline sample digestion with KOH and NaOH, followed by aqueous phase phenylation derivatization with NaBPh4 and solid phase microextraction (SPME) for the determination of methylmercury in typical fish-containing food samples commercially available in Hungary, is reported. The sample preparation procedure along with the applied SPME-GC-pyrolysis-AFS system was validated by measuring certified reference materials (CRM) BCR-464, TORT-2, and a candidate CRM BCR 710. To carry out an estimation of average Hungarian methylmercury exposures via marine fish and/or fish-containing food consumption, 16 commercially available products and 3 pooled representative seafood samples of-according to a previous European survey--the three most consumed fish species in Hungary, herring, sardines, and hake, were analyzed. Methylmercury concentrations of the analyzed samples were in the range 0.016-0.137 microg of MeHg g(-1) dry weight as Hg.

  8. Analysis of the Einstein sample of early-type galaxies

    NASA Technical Reports Server (NTRS)

    Eskridge, Paul B.; Fabbiano, Giuseppina

    1993-01-01

    The EINSTEIN galaxy catalog contains x-ray data for 148 early-type (E and SO) galaxies. A detailed analysis of the global properties of this sample are studied. By comparing the x-ray properties with other tracers of the ISM, as well as with observables related to the stellar dynamics and populations of the sample, we expect to determine more clearly the physical relationships that determine the evolution of early-type galaxies. Previous studies with smaller samples have explored the relationships between x-ray luminosity (L(sub x)) and luminosities in other bands. Using our larger sample and the statistical techniques of survival analysis, a number of these earlier analyses were repeated. For our full sample, a strong statistical correlation is found between L(sub X) and L(sub B) (the probability that the null hypothesis is upheld is P less than 10(exp -4) from a variety of rank correlation tests. Regressions with several algorithms yield consistent results.

  9. Predicting Recreational Water Quality Using Turbidity in the Cuyahoga River, Cuyahoga Valley National Park, Ohio, 2004-7

    USGS Publications Warehouse

    Brady, Amie M.G.; Bushon, Rebecca N.; Plona, Meg B.

    2009-01-01

    The Cuyahoga River within Cuyahoga Valley National Park (CVNP) in Ohio is often impaired for recreational use because of elevated concentrations of bacteria, which are indicators of fecal contamination. During the recreational seasons (May through August) of 2004 through 2007, samples were collected at two river sites, one upstream of and one centrally-located within CVNP. Bacterial concentrations and turbidity were determined, and streamflow at time of sampling and rainfall amounts over the previous 24 hours prior to sampling were ascertained. Statistical models to predict Escherichia coli (E. coli) concentrations were developed for each site (with data from 2004 through 2006) and tested during an independent year (2007). At Jaite, a sampling site near the center of CVNP, the predictive model performed better than the traditional method of determining the current day's water quality using the previous day's E. coli concentration. During 2007, the Jaite model, based on turbidity, produced more correct responses (81 percent) and fewer false negatives (3.2 percent) than the traditional method (68 and 26 percent, respectively). At Old Portage, a sampling site just upstream from CVNP, a predictive model with turbidity and rainfall as explanatory variables did not perform as well as the traditional method. The Jaite model was used to estimate water quality at three other sites in the park; although it did not perform as well as the traditional method, it performed well - yielding between 68 and 91 percent correct responses. Further research would be necessary to determine whether using the Jaite model to predict recreational water quality elsewhere on the river would provide accurate results.

  10. Precise method for the measurement of catalase activity in honey.

    PubMed

    Huidobro, José F; Sánchez, M Pilar; Muniategui, Soledad; Sancho, M Teresa

    2005-01-01

    An improved method is reported for the determination of catalase activity in honey. We tested different dialysis membranes, dialysis fluid compositions and amounts, dialysis temperatures, sample amounts, and dialysis times. The best results were obtained by dialysis of 7.50 g sample in a cellulose dialysis sack, using two 3 L portions of 0.015 M sodium phosphate buffer (pH 7.0) as the dialysis fluid at 4 degrees C for 22 h. As in previous methods, catalase activity was determined on the basis of the rate of disappearance of the substrate, H202, with the H202 determined spectrophotometrically at 400 nm in an assay system containing o-dianisidine and peroxidase. Trials indicated that the best solvent for the o-dianisidine was 0.2 M sodium phosphate buffer, pH 6.1; the best starting H202 concentration was 3 mM; the best HCl concentration for stopping the reaction was 6 N; and the best sample volume for catalase measurement was 7.0 mL. Precision values (relative standard deviations for analyses of 10 subsamples of each of 3 samples) were high, ranging from 0.48% for samples with high catalase activity to 1.98% for samples with low catalase activity.

  11. Capillary electrophoresis coupled with electrochemiluminescence for determination of atomoxetine hydrochloride and the study on its interactions with three proteins.

    PubMed

    Zeng, Hua-jin; Yang, Ran; Zhang, Ying; Li, Jian-jun; Qu, Ling-bo

    2015-03-01

    A simple, rapid and sensitive method for the determination of atomoxetine hydrochloride (AH) by capillary electrophoresis with electrochemiluminescence detection (CE-ECL) using tris(2,2'-bipyridyl) ruthenium (II) was developed. Under optimized conditions, the determinations of AH in capsules and rat plasmas and the study on its interactions with three plasma proteins, including bovine serum albumin, cytochrome c and myoglobin were performed successfully. Relative to some previous studies, in this paper the methodologies for the determination of AH in aqueous solution and spiked plasma systems were established, respectively. By comparing the difference between the two work curves of two systems, the matrix effect in plasma samples on the determination of AH by the CE-ECL method was discussed in detail. The results indicated that the effect of the matrix in plasma samples should not be ignored even if no obvious interference was found in the electropherograms and the establishment of method validation in complex samples by the CE-ECL method was necessary. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Incidence of postoperative hypothermia and the relationship to clinical variables.

    PubMed

    Burns, Shari M; Piotrowski, Kathy; Caraffa, Guy; Wojnakowski, Mary

    2010-10-01

    A prospective, quantitative, correlational study was conducted to determine the incidence of postoperative hypothermia and the relationship of hypothermia to numerous clinical variables previously studied. The study reflects the researchers' interest in updating previous data regarding the incidence of hypothermia. Although hypothermia remains a significant clinical concern, interventions aimed at minimizing hypothermia have evolved over the past 20 years, thus prompting new interest in determining the extent to which hypothermia exists in today's PACU patients. A convenience sample of 287 adult, nonemergency patients scheduled for surgery were included in the study. Hypothermia (temperature <36°C) was demonstrated in only 4% of the sample (N = 287). Because of the low incidence of hypothermia, correlation statistics were not performed. The study provides a foundation for future research regarding this important clinical phenomenon while offering evidence supporting efforts to avoid hypothermia in today's surgical patients. Copyright © 2010 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  13. Extraction, Scrub, and Strip Test Results for the Salt Waste Processing Facility Caustic Side Solvent Extraction Solvent Sample

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, T. B.

    An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D( Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D( Cs) measured 12.5, exceeding the required value of 8. This value is consistent with resultsmore » from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges. This revision was created to correct an error. The previous revision used an incorrect set of temperature correction coefficients which resulted in slight deviations from the correct D( Cs) results.« less

  14. Chemical Characterization of an Envelope B/D Sample from Hanford Tank 241-AZ-102

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hay, M.S.

    2000-08-23

    A sample from Hanford waste tank 241-AZ-102 was received at the Savannah River Technology Center (SRTC) and chemically characterized. The sample containing supernate and a small amount of sludge solids was analyzed as-received. The filtered supernatant liquid, the total dried solids of the sample, and the washed insoluble solids obtained from filtration of the sample were analyzed. A mass balance calculation of the three fractions of the sample analyzed indicate the analytical results appear relatively self-consistent for major components of the sample. However, some inconsistency was observed between results were more than one method of determination was employed and formore » species present in low concentrations. The actinides isotopes, plutonium, americium, and curium, present analytical challenges due to the low concentration of these species and the potential for introduction of small amounts of contamination during sampling handling resulting in large uncertainties. A direct comparison to previous analyses of material from tank 241-AZ-102 showed good agreement with the filtered supernatant liquid. However, the comparison of solids data showed poor agreement. The poor agreement shown between the current results for the solids samples and previous analyses most likely results from the uncertainties associated with obtaining small solids samples from a large non-homogenized waste tank.« less

  15. Optimal extraction of quasar Lyman limit absorption systems from the IUE archive

    NASA Technical Reports Server (NTRS)

    Tytler, David

    1992-01-01

    The IUE archive contains a wealth of information on Lyman limit absorption systems (LLS) in quasar spectra. QSO spectra from the IUE data base were optimally extracted, coadded, and analyzed to yield a homogeneous samples of LLS at low red shifts. This sample comprise 36 LLS, twice the number previously analyzed low z samples. These systems are ideal for the determination of the origin, redshift evolution, ionization, velocity dispersions and the metal abundances of absorption systems. Two of them are also excellent targets for the primordial Deuterium to Hydrogen ratio.

  16. Determination of organic acids in tissues and exudates of maize, lupin, and chickpea by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Erro, Javier; Zamarreño, Angel M; Yvin, Jean-Claude; Garcia-Mina, Jose M

    2009-05-27

    This article describes a fast and simple methodology for the extraction and determination of organic acids in tissues and root exudates of maize, lupin, and chickpea by LC/MS/MS. Its main advantage is that it does not require sample prepurification before HPLC analysis or sample derivatization to improve sensibility. The results obtained showed good precision and accuracy, a recovery close to 100%, and no significant matrix effect. Moreover, the sensibility of the method is in general better than that of previously described methodologies, with detection limits between 15 and 900 pg injected.

  17. Characterization of Water and CO2 Adsorption by Stores 3A Desiccant Samples Using Thermal Gravimetric Analysis and Fourier Transform Infrared Spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    RIVERA, DION A.; ALAM, M. KATHLEEN; MARTIN, LAURA

    2003-02-01

    Two lots of manufactured Type 3a zeolite samples were compared by TGA/IR analysis. The first lot, obtained from Davidson Chemical, a commercial vendor, was characterized during the previous study cycle for its water and water-plus-CO{sub 2} uptake in order to determine whether CO{sub 2} uptake prevented water adsorption by the zeolite. It was determined that CO{sub 2} did not hamper water adsorption using the Davidson zeolite. CO{sub 2} was found on the zeolite surface at dewpoints below -40 C, however it was found to be reversibly adsorbed. During the course of the previous studies, chemical analyses revealed that the Davidsonmore » 3a zeolite contained calcium in significant quantities, along with the traditional counterions potassium and sodium. Chemical analysis of a Type 3a zeolite sample retrieved from Kansas City (heretofore referred to as the ''Stores 3a'' sample) indicated that the Stores sample was a more traditional Type 3a zeolite, containing no calcium. TGA/IR studies this year focused on obtaining CO{sub 2} and water absorbance data from the Stores 3a zeolite. Within the Stores 3a sample, CO{sub 2} was found to be reversibly absorbed within the sample, but only at and below -60 C with 5% CO{sub 2} loading. The amount of CO{sub 2} observed eluting from the Stores zeolite at this condition was similar to what was observed from the Davidson zeolite sample but with a greater uncertainty in the measured value. The results of the Stores 3a studies are summarized within this report.« less

  18. Use of psychotherapy in a representative adult community sample in São Paulo, Brazil

    PubMed Central

    Blay, Sergio L.; Fillenbaum, Gerda G.; da Silva, Paula Freitas R.; Peluso, Erica T.

    2014-01-01

    Little is known about the use of psychotherapy to treat common mental disorders in a major city in a middle income country. Data come from in-home interviews with a stratified random sample of 2,000 community residents age 18–65 in the city of São Paulo, Brazil. The information obtained included sociodemographic characteristics; psychotropic drugs; mental status; and lifetime, previous 12 months, and current use of psychotherapy. Logistic regression was used to examine determinants of use of psychotherapy. Of the sample, 22.7% met General Health Questionnaire-12 criteria for common mental disorders. Lifetime, previous 12 months, and current use of psychotherapy were reported by 14.6%, 4.6%, and 2.3% of the sample respectively. Users were typically women, more educated, higher income, not married, unemployed, with common mental disorders. Further analysis found that 47% (with higher education and income) paid out-of-pocket, and 53% used psychotropic medication. Psychotherapy does not appear to be the preferred treatment for common mental disorders. PMID:25118139

  19. Improved COD Measurements for Organic Content in Flowback Water with High Chloride Concentrations.

    PubMed

    Cardona, Isabel; Park, Ho Il; Lin, Lian-Shin

    2016-03-01

    An improved method was used to determine chemical oxygen demand (COD) as a measure of organic content in water samples containing high chloride content. A contour plot of COD percent error in the Cl(-)-Cl(-):COD domain showed that COD errors increased with Cl(-):COD. Substantial errors (>10%) could occur in low Cl(-):COD regions (<300) for samples with low (<10 g/L) and high chloride concentrations (>25 g/L). Applying the method to flowback water samples resulted in COD concentrations ranging in 130 to 1060 mg/L, which were substantially lower than the previously reported values for flowback water samples from Marcellus Shale (228 to 21 900 mg/L). It is likely that overestimations of COD in the previous studies occurred as result of chloride interferences. Pretreatment with mercuric sulfate, and use of a low-strength digestion solution, and the contour plot to correct COD measurements are feasible steps to significantly improve the accuracy of COD measurements.

  20. Noble gas isotopes in mineral springs and wells within the Cascadia forearc, Washington, Oregon, and California

    USGS Publications Warehouse

    McCrory, Patricia A.; Constantz, James E.; Hunt, Andrew G.

    2017-01-31

    IntroductionThis U.S. Geological Survey report presents laboratory analyses along with field notes for an exploratory study to document the relative abundance of noble gases in mineral springs and water wells within the Cascadia forearc of Washington, Oregon, and California (fig. 1). This report describes 14 samples collected in 2014 and 2015 and complements a previous report that describes 9 samples collected in 2012 and 2013 (McCrory and others, 2014b). Estimates of the depth to the underlying Juan de Fuca oceanic plate beneath sample sites are derived from the McCrory and others (2012) slab model. Some of the springs have been previously sampled for chemical analyses (Mariner and others, 2006), but none of the springs or wells currently has publicly available noble gas data. The helium and neon isotope values and ratios presented below are used to determine the sources and mixing history of these mineral and well waters (for example, McCrory and others, 2016).

  1. The Flynn Effect: A Meta-analysis

    PubMed Central

    Trahan, Lisa; Stuebing, Karla K.; Hiscock, Merril K.; Fletcher, Jack M.

    2014-01-01

    The “Flynn effect” refers to the observed rise in IQ scores over time, resulting in norms obsolescence. Although the Flynn effect is widely accepted, most approaches to estimating it have relied upon “scorecard” approaches that make estimates of its magnitude and error of measurement controversial and prevent determination of factors that moderate the Flynn effect across different IQ tests. We conducted a meta-analysis to determine the magnitude of the Flynn effect with a higher degree of precision, to determine the error of measurement, and to assess the impact of several moderator variables on the mean effect size. Across 285 studies (N = 14,031) since 1951 with administrations of two intelligence tests with different normative bases, the meta-analytic mean was 2.31, 95% CI [1.99, 2.64], standard score points per decade. The mean effect size for 53 comparisons (N = 3,951) (excluding three atypical studies that inflate the estimates) involving modern (since 1972) Stanford-Binet and Wechsler IQ tests (2.93, 95% CI [2.3, 3.5], IQ points per decade) was comparable to previous estimates of about 3 points per decade, but not consistent with the hypothesis that the Flynn effect is diminishing. For modern tests, study sample (larger increases for validation research samples vs. test standardization samples) and order of administration explained unique variance in the Flynn effect, but age and ability level were not significant moderators. These results supported previous estimates of the Flynn effect and its robustness across different age groups, measures, samples, and levels of performance. PMID:24979188

  2. Update on Development of the Potassium-Argon Laser Experiment (KArLE) Instrument for In Situ Geochronology

    NASA Technical Reports Server (NTRS)

    Cohen, Barbara A.; Li, Z.-H.; Miller, J. S.; Brinckerhoff, W. B.; Clegg, S. M.; Mahaffy, P. R.; Swindle, T. D.; Wiens, R. C.

    2013-01-01

    Absolute dating of planetary samples is an essential tool to establish the chronology of geological events, including crystallization history, magmatic evolution, and alteration. We are addressing this challenge by developing the Potassium (K) -- Argon Laser Experiment (KArLE), building on previous work to develop a K-Ar in situ instrument. KArLE ablates a rock sample, determines the K in the plasma state using laser-induced breakdown spectroscopy (LIBS), measures the liberated Ar using quadrupole mass spectrometry (QMS), and relates the two by the volume of the ablated pit using laser confocal microscopy (LCM). Our goal is for the KArLE instrument to be capable of determining the age of several kinds of planetary samples to address a wide range of geochronolgy problems in planetary science.

  3. Diagnosis of pregnancy in moose using a bovine assay for pregnancy-specific protein B.

    PubMed

    Haigh, J C; Dalton, W J; Ruder, C A; Sasser, R G

    1993-11-01

    Blood samples were collected from 26 moose (Alces alces ) and evaluated for the presence of an antigen that cross-reacted with antisera to bovine pregnancy-specific protein B (P-SPB). The objective of this study was to determine if the P-SPB radioimmunoassay (RIA) was a reliable indicator of pregnancy in these animals. In the first year of the study calf production the following summer was used as the index of previous pregnancy. In the second year all females were subjected to palpation per rectum after chemical immobilization. Seven of the 10 cows sampled in the first year were also sampled in the second year. All animals determined pregnant by rectal palpation were positive for P-SPB; however, P-SPB was not detected in males.

  4. Self-harming in depressed patients: pattern analysis.

    PubMed

    Parker, G; Malhi, Gin; Mitchell, Philip; Kotze, Beth; Wilhelm, Kay; Parker, Kay

    2005-10-01

    As deliberate self-harm (DSH) is a common concomitant of depressive disorders, we undertook a study examining the relevance of possible determinants and correlates of DSH. Three separate samples of depressed outpatients were studied to determine consistency of identified factors across samples, with principal analyses involving gender, age and diagnosis-matched DSH and non-DSH subjects. Across the samples, some 20% of subjects admitted to episodes of DSH. Women reported higher rates and there was a consistent trend for higher rates in bipolar patients. Univariate analyses examined the relevance of several sociodemographic variables, illicit drug and alcohol use, past deprivational and abusive experiences, past suicidal attempts and disordered personality functioning. Multivariate analyses consistently identified previous suicide attempts and high 'acting out' behaviours across the three samples, suggesting the relevance of an externalizing response to stress and poor impulse control. Results assist the identification and management of depressed patients who are at greater risk of DSH behaviours.

  5. Determination of the resistance of fabric printed with triclosan microcapsules to the action of soil micro-flora

    NASA Astrophysics Data System (ADS)

    Golja, B.; Forte Tavčer, P.

    2017-10-01

    Microcapsules with a pressure-sensitive melamine-formaldehyde wall and triclosan core were printed to 100% cotton fabric with screen printing technique. Previous research showed excellent antibacterial activity (estimated for E. Coli and S. Aureus) of such fabric, so our aim in this research was to determine its resistance to the action of microorganisms present in the soil. The soil burial test was conducted. The breaking strength of the buried samples was measured and also the scanning electron microscope analysis was done. The results showed that none of the samples are resistant to decay. It is evident from SEM micrographs that on all of the buried samples greater morphological changes occur due to the functions of the soil microflora. It can be concluded that the samples printed with triclosan microcapsules are biodegradable which is environmentally preferable.

  6. Level of endogenous formaldehyde in maple syrup as determined by spectrofluorimetry.

    PubMed

    Lagacé, Luc; Guay, Stéphane; Martin, Nathalie

    2003-01-01

    The level of endogenous formaldehyde in maple syrup was established from a large number (n = 300) of authentic maple syrup samples collected during 2000 and 2001 in the province of Quebec, Canada. The average level of formaldehyde from these authentic samples was measured at 0.18 mg/kg in 2000 and 0.28 mg/kg in 2001, which is lower than previously published. These average values can be attributed to the improved spectrofluorimetric method used for the determination. However, the formaldehyde values obtained demonstrate a relatively large distribution with maximums observed at 1.04 and 1.54 mg/kg. These values are still under the maximum tolerance level of 2.0 mg/kg paraformaldehyde pesticide residue. Extensive heat treatment of maple syrup samples greatly enhanced the formaldehyde concentration of the samples, suggesting that extensive heat degradation of the sap constituents during evaporation could be responsible for the highest formaldehyde values in maple syrup.

  7. [Convertibility of the data determined by ICP-AES and FAAS for soil available K and Na].

    PubMed

    Zhang, Jian-min; Wang, Meng; Ge, Xiao-ping; Wu, Jian-zhi; Ge, Ying; Li, Shi-peng; Chang, Jie

    2009-05-01

    In recent years, inductively coupled plasma atomic emission spectrometry (ICP-AES) have been commonly used to determine the soil available K and Na with the extraction solution of HCl-H2SO4, while previous data of soil available K and Na were measured by flame atomic absorption spectrometry (FAAS) with the extraction solution of NH4OAc. In order to utilize previous data, quest for the convertibility of the data determined by ICP-AES and FAAS, and compare the data determined by both methods, the authors chose four types of soil to determine soil available K and Na by ICP-AES and FAAS, respectively. Four types of soil represent grit soil, clay, silt from river and silt from sea, respectively. Soil samples included four types of soil and these samples represent different soil nutrition. The authors analyzed the correlations of two kinds of measured data. The paired samples t-test proves that there was significantly positively correlation between these two methods. The correlation coefficient of the data between these two methods for measuring soil available K is 0.98. The results of soil available K determined by the two methods can be conversed through the formula, y = l.14x + 6.53 (R2 = 0.91, n=24, p < 0.001). As for Na, although there is a significantly positively correlation between these two methods, the slopes of single model of clay and grit soil were different from that of general model. And so the results determined by the two methods can be conversed through different formula according to the types of soil, that is, for clay: y = l.23x + 10.03; for grit soil: y = 3.12x - 23.03; for silt: y = 0.60x. In conclusion, the authors' results showed that previous data of available K and Na measured by FAAS with the extraction solution of NH4OAc were available. And these data were comparable to the data measured by ICP-AES through definite formula The authors' results also suggested that ICP-AES was preferable when many elements were measured at the same time. Under this condition, ICP-AES was economical, efficient and reliable.

  8. Multidimensional Relationships in the WAIS-R Subscales and Demographic Variables.

    ERIC Educational Resources Information Center

    Chastain, Robert L.; Joe, George W.

    This study attempts to integrate and extend previous research by multivariate investigation to determine multidimensional relationships among both the Wechsler Adult Intelligence Scale-Revised (WAIS-R) subscales and the demographic variables for the 1981 WAIS-R standardization sample. Canonical correlation with orthogonal rotation of composite…

  9. Cognitive Tests in Early Childhood: Psychometric and Cultural Considerations

    ERIC Educational Resources Information Center

    Williams, Marian E.; Sando, Lara; Soles, Tamara Glen

    2014-01-01

    Cognitive assessment of young children contributes to high-stakes decisions because results are often used to determine eligibility for early intervention and special education. Previous reviews of cognitive measures for young children highlighted concerns regarding adequacy of standardization samples, steep item gradients, and insufficient floors…

  10. Detection of sexually transmitted pathogens in patients with chronic prostatitis/chronic pelvic pain: a prospective clinical study.

    PubMed

    Papeš, Dino; Pasini, Miram; Jerončić, Ana; Vargović, Martina; Kotarski, Viktor; Markotić, Alemka; Škerk, Višnja

    2017-05-01

    In <10% of patients with prostatitis syndrome, a causative uropathogenic organism can be detected. It has been shown that certain organisms that cause sexually transmitted infections can also cause chronic bacterial prostatitis, which can be hard to diagnose and treat appropriately because prostatic samples obtained by prostatic massage are not routinely tested to detect them. We conducted a clinical study to determine the prevalence of Chlamydia, mycoplasma, and trichomonas infection in 254 patients that were previously diagnosed and treated for chronic prostatitis/chronic pelvic pain syndrome due to negative urethral swab, urine, and prostate samples. Urethral swabs and standard Meares-Stamey four-glass tests were done. Detailed microbiological analysis was conducted to detect the above organisms. Thirty-five (13.8%) patients had positive expressed prostatic secretions/VB3 samples, of which 22 (10.1%) were sexually transmitted organisms that were not detected on previous tests.

  11. Comparison of the Roche Cobas® 4800 HPV assay to Roche Amplicor for detection of high-risk human papillomavirus.

    PubMed

    Phillips, S; Cornall, A M; Machalek, D A; Garland, S M; Bateson, D; Garefalakis, M; Tabrizi, S N

    2016-08-01

    Roche Amplicor HPV (AMP) had previously been used for detection of high-risk human papillomavirus (HR-HPV) in epidemiological and clinical studies. As this assay is no longer available, we compared its performance using PreservCyt samples from women aged of 18-24 years attending for routine cervical cytology screening to Roche Cobas® 4800 (Cobas) to determine if subsequent studies could continue using the Cobas assay. Overall 507 samples were tested on Cobas and compared to previous AMP results, with discrepant samples tested on Roche Linear Array. Overall, agreement between the Cobas and AMP for the presence of HR HPV types was very high (κ = 0.81) (95 % CI: 0.76 - 0.87) with percentage agreement of 91.57 %. Cobas is comparable to AMP for the detection of HR-HPV types in a community recruited cohort of healthy women.

  12. A compilation of K-Ar-ages for southern California

    USGS Publications Warehouse

    Miller, Fred K.; Morton, Douglas M.; Morton, Janet L.; Miller, David M.

    2014-01-01

    The purpose of this report is to make available a large body of conventional K-Ar ages for granitic, volcanic, and metamorphic rocks collected in southern California. Although one interpretive map is included, the report consists primarily of a systematic listing, without discussion or interpretation, of published and unpublished ages that may be of value in future regional and other geologic studies. From 1973 to 1979, 468 rock samples from southern California were collected for conventional K-Ar dating under a regional geologic mapping project of Southern California (predecessor of the Southern California Areal Mapping Project). Most samples were collected and dated between 1974 and 1977. For 61 samples (13 percent of those collected), either they were discarded for varying reasons, or the original collection data were lost. For the remaining samples, 518 conventional K-Ar ages are reported here; coexisting mineral pairs were dated from many samples. Of these K-Ar ages, 225 are previously unpublished, and identified as such in table 1. All K-Ar ages are by conventional K-Ar analysis; no 40Ar/39Ar dating was done. Subsequent to the rock samples collected in the 1970s and reported here, 33 samples were collected and 38 conventional K-Ar ages determined under projects directed at (1) characterization of the Mesozoic and Cenozoic igneous rocks in and on both sides of the Transverse Ranges and (2) clarifying the Mesozoic and Cenozoic tectonics of the eastern Mojave Desert. Although previously published (Beckerman et al., 1982), another eight samples and 11 conventional K-Ar ages are included here, because they augment those completed under the previous two projects.

  13. Determinants of women's likelihood of vaginal self-sampling for human papillomavirus to screen for cervical cancer in Taiwan: a cross-sectional study.

    PubMed

    Chen, Shu-Ling; Hsieh, Pao-Chun; Chou, Chia-Hui; Tzeng, Ya-Ling

    2014-11-25

    Many Taiwanese women (43.8%) did not participate in regular cervical screening in 2011. An alternative to cervical screening, self-sampling for human papillomavirus (HPV), has been available at no cost under Taiwan's National Health Insurance since 2010, but the extent and likelihood of HPV self-sampling were unknown. A cross-sectional study was performed to explore determinants of women's likelihood of HPV self-sampling. Data were collected by questionnaire from a convenience sample of 500 women attending hospital gynecologic clinics in central Taiwan from June to October 2012. Data were analyzed by descriptive statistics, chi-square test, and logistic regression. Of 500 respondents, 297 (59.4%) had heard of HPV; of these 297 women, 69 (23%) had self-sampled for HPV. Among the 297 women who had heard of HPV, 234 (78.8%) considered cost a priority for HPV self-sampling. Likelihood of HPV self-sampling was determined by previous Pap testing, high perceived risk of cervical cancer, willingness to self-sample for HPV, high HPV knowledge, and cost as a priority consideration. Outreach efforts to increase the acceptability of self-sampling for HPV testing rates should target women who have had a Pap test, perceive themselves at high risk for cervical cancer, are willing to self-sample for HPV, have a high level of HPV knowledge, and for whom the cost of self-sampling covered by health insurance is a priority.

  14. Non-invasive determination of glucose directly in raw fruits using a continuous flow system based on microdialysis sampling and amperometric detection at an integrated enzymatic biosensor.

    PubMed

    Vargas, E; Ruiz, M A; Campuzano, S; Reviejo, A J; Pingarrón, J M

    2016-03-31

    A non-destructive, rapid and simple to use sensing method for direct determination of glucose in non-processed fruits is described. The strategy involved on-line microdialysis sampling coupled with a continuous flow system with amperometric detection at an enzymatic biosensor. Apart from direct determination of glucose in fruit juices and blended fruits, this work describes for the first time the successful application of an enzymatic biosensor-based electrochemical approach to the non-invasive determination of glucose in raw fruits. The methodology correlates, through previous calibration set-up, the amperometric signal generated from glucose in non-processed fruits with its content in % (w/w). The comparison of the obtained results using the proposed approach in different fruits with those provided by other method involving the same commercial biosensor as amperometric detector in stirred solutions pointed out that there were no significant differences. Moreover, in comparison with other available methodologies, this microdialysis-coupled continuous flow system amperometric biosensor-based procedure features straightforward sample preparation, low cost, reduced assay time (sampling rate of 7 h(-1)) and ease of automation. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. THE MEASUREMENT OF RADIATION EXPOSURE OF ASTRONAUTS BY RADIOCHEMICAL TECHNIQUES October 6,1969 Through January 4, 1970

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brodzinski, R. L.; Rancitelli, L. A.; Haller, W. A.

    1970-01-15

    The urine and feces specimens from the Apollo 11 mission were analyzed for their radionuclide content. Estimates of cosmic radiation dose received by the astronauts were difficult to determine due to decay of the short-lived radionuclides during quarantine. The concentrations of {sup 7}Be, {sup 22}Na, {sup 40}K, {sup 59}Fe, {sup 60}Co, and {sup 137}Cs were determined. No {sup 147}Pm was observed in any of the samples. The concentrations of 16 major, minor, and trace elements were determined in fecal samples from Apollos 8 and 10. Large discrepancies between the excretion rates and normal dietary intakes were noted for cobalt, iron,more » tin , and potassium. An interpretation of the hazards these deviations may produce requires the determination of the elemental concentrations of the foodstuffs used during these missions. The fecal samples from the Apollo 11 mission were analyzed for glass fiber content. One anomalous sample was observed having a glass fiber content twofold greater than any previously measured specimen. A piece of the outer thermal coating of the Apollo 12 spacecraft was analyzed for cosmic-ray-induced radioactivity. Beryllium-7 was observed .« less

  16. Evaluation of the genetic distinctiveness of Greater Sage-grouse in the Bi-State Planning Area

    USGS Publications Warehouse

    Oyler-McCance, Sara J.; Casazza, Michael L.

    2011-01-01

    The purpose of this study was to further characterize a distinct population of Greater Sage-grouse: the population located along the border between Nevada and California (Bi-State Planning Area) and centered around the Mono Basin. This population was previously determined to be genetically distinct from other Greater Sage-grouse populations across their range. Previous genetic work focused on characterizing genetic variation across the species' range and thereby used a coarse sampling approach for species characterization. The goal of this study was to investigate this population further by obtaining samples from breeding locations within the population and analyzing those samples with the same mitochondrial and microsatellite loci used in previous studies. Blood samples were collected in six locations within the Bi-State Planning Area. Genetic data from subpopulations were then compared with each other and also with two populations outside of the Bi-State Planning Area. Particular attention was paid to subpopulation boundaries and internal dynamics by drawing comparisons among particular regions within the Bi-State Planning Area and regions proximal to it. All newly sampled subpopulations contained mitochondrial haplotypes and allele frequencies that were consistent with the genetically unique Bi-State (Mono Basin) Greater Sage-grouse described previously. This reinforces the fact that this group of Greater Sage-grouse is genetically unique and warrants special attention. Maintaining the genetic integrity of this population could protect the evolutionary potential of this population of Greater Sage-grouse. Additionally, the White Mountains subpopulation was found to be significantly distinct from all other Bi-State subpopulations.

  17. Gamma-ray spectroscopy in the decay of (83)Se to levels of (83)Br.

    PubMed

    Krane, K S

    2015-03-01

    High-resolution γ ray spectroscopy experiments have been done to study the emissions from the radioactive decay of 22-min (83g)Se produced from neutron capture using samples of enriched (82)Se. Energy and intensity values have been obtained to roughly an order of magnitude greater precision than in previous studies. Based on energy sums, 2 new levels are proposed in the daughter (83)Br and one previously proposed level is shown to be doubtful. Some 25 new transitions appear to decay with the (83)Se halflife, about half of which can be accommodated among the previous or newly proposed levels. Several previous γ ray placements are shown to be inconsistent with the new determinations of the (83)Br energy levels, but cannot be accommodated anywhere else among the known levels. As a result of the missing γ ray placements, some of the β branchings in the decay to levels of (83)Br appear to be negative. Gamma rays from the 2.4-h decay of the daughter (83)Br to levels of (83)Kr have also been observed, along with decays of (81g)(,m)Se present as a small impurity in the enriched samples and also as a strong component in irradiated samples of natural Se. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Amino acid distribution in meteorites: diagenesis, extraction methods, and standard metrics in the search for extraterrestrial biosignatures.

    PubMed

    McDonald, Gene D; Storrie-Lombardi, Michael C

    2006-02-01

    The relative abundance of the protein amino acids has been previously investigated as a potential marker for biogenicity in meteoritic samples. However, these investigations were executed without a quantitative metric to evaluate distribution variations, and they did not account for the possibility of interdisciplinary systematic error arising from inter-laboratory differences in extraction and detection techniques. Principal component analysis (PCA), hierarchical cluster analysis (HCA), and stochastic probabilistic artificial neural networks (ANNs) were used to compare the distributions for nine protein amino acids previously reported for the Murchison carbonaceous chondrite, Mars meteorites (ALH84001, Nakhla, and EETA79001), prebiotic synthesis experiments, and terrestrial biota and sediments. These techniques allowed us (1) to identify a shift in terrestrial amino acid distributions secondary to diagenesis; (2) to detect differences in terrestrial distributions that may be systematic differences between extraction and analysis techniques in biological and geological laboratories; and (3) to determine that distributions in meteoritic samples appear more similar to prebiotic chemistry samples than they do to the terrestrial unaltered or diagenetic samples. Both diagenesis and putative interdisciplinary differences in analysis complicate interpretation of meteoritic amino acid distributions. We propose that the analysis of future samples from such diverse sources as meteoritic influx, sample return missions, and in situ exploration of Mars would be less ambiguous with adoption of standardized assay techniques, systematic inclusion of assay standards, and the use of a quantitative, probabilistic metric. We present here one such metric determined by sequential feature extraction and normalization (PCA), information-driven automated exploration of classification possibilities (HCA), and prediction of classification accuracy (ANNs).

  19. Characterization of the Distribution of Siderophile and Highly Siderophile Elements in the Milton and Eagle Station Pallasites

    NASA Technical Reports Server (NTRS)

    Hillebrand, J. T.; McDonough, W. F.; Walker, R. J.; Piccoli, P. M.

    2004-01-01

    We examine the partitioning characteristics of several siderophile elements and HSE in the Eagle Station and Milton pallasites to determine if the D(sup Metal/Silicate) in natural systems are comparable to the range of values determined for synthetic systems. Eagle Station and Milton are particularly appropriate for this type of study because previous studies have shown that bulk samples of these meteorites have much higher abundances of siderophile elements and HSE than bulk samples of main group pallasites or mesosiderites. Thus, the expectation that initiated this study was that the abundances of at least some elements of interest present in the silicate phases may be at levels sufficiently high to be determined via in situ spot analysis using laser ablation ICP-MS.

  20. Administrative database code accuracy did not vary notably with changes in disease prevalence.

    PubMed

    van Walraven, Carl; English, Shane; Austin, Peter C

    2016-11-01

    Previous mathematical analyses of diagnostic tests based on the categorization of a continuous measure have found that test sensitivity and specificity varies significantly by disease prevalence. This study determined if the accuracy of diagnostic codes varied by disease prevalence. We used data from two previous studies in which the true status of renal disease and primary subarachnoid hemorrhage, respectively, had been determined. In multiple stratified random samples from the two previous studies having varying disease prevalence, we measured the accuracy of diagnostic codes for each disease using sensitivity, specificity, and positive and negative predictive value. Diagnostic code sensitivity and specificity did not change notably within clinically sensible disease prevalence. In contrast, positive and negative predictive values changed significantly with disease prevalence. Disease prevalence had no important influence on the sensitivity and specificity of diagnostic codes in administrative databases. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Emotional Intelligence Levels and Counselling Skills of Prospective Psychological Counsellors

    ERIC Educational Resources Information Center

    Odaci, Hatice; Degerli, Fatma Irem; Bolat, Neslihan

    2017-01-01

    This research aimed to determine the correlation between emotional intelligence (EI) and counselling skills of Turkish prospective psychological counsellors and to investigate differences in both EI and counselling skills in terms of sex, previous experience of group studies, and class levels. Within a correlational pattern, the sample of the…

  2. A Multivariate Model of Achievement in Geometry

    ERIC Educational Resources Information Center

    Bailey, MarLynn; Taasoobshirazi, Gita; Carr, Martha

    2014-01-01

    Previous studies have shown that several key variables influence student achievement in geometry, but no research has been conducted to determine how these variables interact. A model of achievement in geometry was tested on a sample of 102 high school students. Structural equation modeling was used to test hypothesized relationships among…

  3. Another Look at the Use of the Minnesota Multiphasic Personality Inventory as an Index to "Escapism"

    ERIC Educational Resources Information Center

    Adams, Thomas C.; West, Judy E.

    1976-01-01

    Attempts to reevaluate Beall and Panton's MMPI escape scale on what presumably would be a more appropriate escapee sample than that used in previous studies. This would help to determine whether a revision of this escape scale should be undertaken. (Author/RK)

  4. Integrated fiducial sample mount and software for correlated microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Timothy R McJunkin; Jill R. Scott; Tammy L. Trowbridge

    2014-02-01

    A novel design sample mount with integrated fiducials and software for assisting operators in easily and efficiently locating points of interest established in previous analytical sessions is described. The sample holder and software were evaluated with experiments to demonstrate the utility and ease of finding the same points of interest in two different microscopy instruments. Also, numerical analysis of expected errors in determining the same position with errors unbiased by a human operator was performed. Based on the results, issues related to acquiring reproducibility and best practices for using the sample mount and software were identified. Overall, the sample mountmore » methodology allows data to be efficiently and easily collected on different instruments for the same sample location.« less

  5. Aggregated particles caused by instrument artifact

    NASA Astrophysics Data System (ADS)

    Pierce, Ashley M.; Loría-Salazar, S. Marcela; Arnott, W. Patrick; Edwards, Grant C.; Miller, Matthieu B.; Gustin, Mae S.

    2018-04-01

    Previous studies have indicated that superaggregates, clusters of aggregates of soot primary particles, can be formed in large-scale turbulent fires. Due to lower effective densities, higher porosity, and lower aerodynamic diameters, superaggregates may pass through inlets designed to remove particles < 2.5 µm in aerodynamic diameter (PM2.5). Ambient particulate matter samples were collected at Peavine Peak, NV, USA (2515 m) northwest of Reno, NV, USA from June to November 2014. The Teledyne Advanced Pollution Instrumentation (TAPI) 602 BetaPlus particulate monitor was used to collect PM2.5 on two filter types. During this time, aggregated particles > 2.5 µm in aerodynamic diameter were collected on 36 out of 158 sample days. On preliminary analysis, it was thought that these aggregated particles were superaggregates, depositing past PM10 (particles < 10 µm in aerodynamic diameter) pre-impactors and PM2.5 cyclones. However, further analysis revealed that these aggregated particles were dissimilar to superaggregates observed in previous studies, both in morphology and in elemental composition. To determine if the aggregated particles were superaggregates or an instrument artifact, samples were investigated for the presence of certain elements, the occurrence of fires, high relative humidity and wind speeds, as well as the use of generators on site. Samples with aggregated particles, referred to as aggregates, were analyzed using a scanning electron microscope for size and shape and energy dispersive X-ray spectroscopy was used for elemental analysis. It was determined, based on the high amounts of aluminum present in the aggregate samples, that a sampling artifact associated with the sample inlet and prolonged, high wind events was the probable reason for the observed aggregates.

  6. Simultaneous determination of V, Ni and Fe in fuel fly ash using solid sampling high resolution continuum source graphite furnace atomic absorption spectrometry.

    PubMed

    Cárdenas Valdivia, A; Vereda Alonso, E; López Guerrero, M M; Gonzalez-Rodriguez, J; Cano Pavón, J M; García de Torres, A

    2018-03-01

    A green and simple method has been proposed in this work for the simultaneous determination of V, Ni and Fe in fuel ash samples by solid sampling high resolution continuum source graphite furnace atomic absorption spectrometry (SS HR CS GFAAS). The application of fast programs in combination with direct solid sampling allows eliminating pretreatment steps, involving minimal manipulation of sample. Iridium treated platforms were applied throughout the present study, enabling the use of aqueous standards for calibration. Correlation coefficients for the calibration curves were typically better than 0.9931. The concentrations found in the fuel ash samples analysed ranged from 0.66% to 4.2% for V, 0.23-0.7% for Ni and 0.10-0.60% for Fe. Precision (%RSD) were 5.2%, 10.0% and 9.8% for V, Ni and Fe, respectively, obtained as the average of the %RSD of six replicates of each fuel ash sample. The optimum conditions established were applied to the determination of the target analytes in fuel ash samples. In order to test the accuracy and applicability of the proposed method in the analysis of samples, five ash samples from the combustion of fuel in power stations, were analysed. The method accuracy was evaluated by comparing the results obtained using the proposed method with the results obtained by ICP OES previous acid digestion. The results showed good agreement between them. The goal of this work has been to develop a fast and simple methodology that permits the use of aqueous standards for straightforward calibration and the simultaneous determination of V, Ni and Fe in fuel ash samples by direct SS HR CS GFAAS. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Effects of cooking methods on the iron and zinc contents in cowpea (Vigna unguiculata) to combat nutritional deficiencies in Brazil

    PubMed Central

    Pereira, Elenilda J.; Carvalho, Lucia M. J.; Dellamora-Ortiz, Gisela M.; Cardoso, Flávio S. N.; Carvalho, José L. V.; Viana, Daniela S.; Freitas, Sidinea C.; Rocha, Maurisrael M.

    2014-01-01

    Background Because iron deficiency anemia is prevalent in developing countries, determining the levels of iron and zinc in beans, the second most consumed staple food in Brazil, is essential, especially for the low-income people who experience a deficiency of these minerals in their diet. Objectives This study aimed to evaluate the effect of cooking methods by measuring the iron and zinc contents in cowpea cultivars before and after soaking to determine the retention of these minerals. Methods The samples were cooked in both regular pans and pressure cookers with and without previous soaking. Mineral analyses were carried out by Spectrometry of Inductively Coupled Plasma (ICP). Results The results showed high contents of iron and zinc in raw samples as well as in cooked ones, with the use of regular pan resulting in greater percentage of iron retention and the use of pressure cooker ensuring higher retention of zinc. Conclusions The best retention of iron was found in the BRS Aracê cultivar prepared in a regular pan with previous soaking. This cultivar may be indicated for cultivation and human consumption. The best retention of zinc was found for the BRS Tumucumaque cultivar prepared in a pressure cooker without previous soaking. PMID:24624050

  8. Correlation between Volume of Apical Periodontitis Determined by Cone-beam Computed Tomography Analysis and Endotoxin Levels Found in Primary Root Canal Infection.

    PubMed

    Cardoso, Flávia G R; Ferreira, Nádia S; Martinho, Frederico C; Nascimento, Gustavo G; Manhães, Luiz R C; Rocco, Marco A; Carvalho, Cláudio A T; Valera, Marcia C

    2015-07-01

    This clinical study was conducted to correlate the levels of endotoxins and bacterial counts found in primary endodontic infection with the volume of periapical bone destruction determined by cone-beam computed tomography (CBCT) analysis. Moreover, the levels of bacteria and endotoxins were correlated with the development of clinical features. Twenty-four root canals with primary endodontic disease and apical periodontitis were selected. Clinical features such as pain on palpation, pain on percussion, and previous episode of pain were recorded. The volume (cubic millimeters) of periapical bone destruction was determined by CBCT analysis. Endotoxins and bacterial samplings were collected by using sterile/apyrogenic paper points. Endotoxins were quantified by using limulus amebocyte lysate assay (KQCL test), and bacterial count (colony-forming units [CFU]/mL) was determined by using anaerobic culture techniques. Data were analyzed by Pearson correlation and multiple logistic regression (P < .05). Endotoxins and bacteria were detected in 100% of the root canal samples (24 of 24), with median values of 10.92 endotoxin units (EU)/mL (1.75-128 EU/mL) and 7.5 × 10(5) CFU/mL (3.20 × 10(5)-8.16 × 10(6) CFU/mL), respectively. The median volume of bone destruction determined by CBCT analysis was 100 mm(3) (10-450 mm(3)). The multiple regression analysis revealed a positive correlation between higher levels of endotoxins present in root canal infection and larger volume of bone destruction (P < .05). Moreover, higher levels of endotoxins were also correlated with the presence of previous pain (P < .05). Our findings revealed that the levels of endotoxins found in root canal infection are related to the volume of periapical bone destruction determined by CBCT analysis. Moreover, the levels of endotoxin are related to the presence of previous pain. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. Determining Optimal Location and Numbers of Sample Transects for Characterization of UXO Sites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BILISOLY, ROGER L.; MCKENNA, SEAN A.

    2003-01-01

    Previous work on sample design has been focused on constructing designs for samples taken at point locations. Significantly less work has been done on sample design for data collected along transects. A review of approaches to point and transect sampling design shows that transects can be considered as a sequential set of point samples. Any two sampling designs can be compared through using each one to predict the value of the quantity being measured on a fixed reference grid. The quality of a design is quantified in two ways: computing either the sum or the product of the eigenvalues ofmore » the variance matrix of the prediction error. An important aspect of this analysis is that the reduction of the mean prediction error variance (MPEV) can be calculated for any proposed sample design, including one with straight and/or meandering transects, prior to taking those samples. This reduction in variance can be used as a ''stopping rule'' to determine when enough transect sampling has been completed on the site. Two approaches for the optimization of the transect locations are presented. The first minimizes the sum of the eigenvalues of the predictive error, and the second minimizes the product of these eigenvalues. Simulated annealing is used to identify transect locations that meet either of these objectives. This algorithm is applied to a hypothetical site to determine the optimal locations of two iterations of meandering transects given a previously existing straight transect. The MPEV calculation is also used on both a hypothetical site and on data collected at the Isleta Pueblo to evaluate its potential as a stopping rule. Results show that three or four rounds of systematic sampling with straight parallel transects covering 30 percent or less of the site, can reduce the initial MPEV by as much as 90 percent. The amount of reduction in MPEV can be used as a stopping rule, but the relationship between MPEV and the results of excavation versus no-further-action decisions is site specific and cannot be calculated prior to the sampling. It may be advantageous to use the reduction in MPEV as a stopping rule for systematic sampling across the site that can then be followed by focused sampling in areas identified has having UXO during the systematic sampling. The techniques presented here provide answers to the questions of ''Where to sample?'' and ''When to stop?'' and are capable of running in near real time to support iterative site characterization campaigns.« less

  10. Determination of formetanate hydrochloride in fruit samples using liquid chromatography-mass selective detection or -tandem mass spectrometry.

    PubMed

    Podhorniak, Lynda V; Kamel, Alaa; Rains, Diane M

    2010-05-26

    A rapid multiresidue method that captures residues of the insecticide formetanate hydrochloride (FHCl) in selected fruits is described. The method was used to provide residue data for dietary exposure determinations of FHCl. Using an acetonitrile extraction with a dispersive cleanup based on AOAC International method 2007.01, also known as QuEChERS, which was further modified and streamlined, thousands of samples were successfully analyzed for FHCl residues. FHCl levels were determined both by liquid chromatography-single-stage mass spectrometry (LC-MS) and ultraperformance liquid chromatography (UPLC)-tandem mass spectrometry (LC-MS/MS). The target limit of detection (LOD) and the limit of quantitation (LOQ) achieved for FHCl were 3.33 and 10 ng/g, respectively, with LC-MS and 0.1 and 0.3 ng/g, respectively, with LC-MS/MS. Recoveries at these previously unpublished levels ranged from 95 to 109%. A set of 20-40 samples can be prepared in one working day by two chemists.

  11. Quality control assurance of strontium-90 in foodstuffs by LSC.

    PubMed

    Lopes, I; Mourato, A; Abrantes, J; Carvalhal, G; Madruga, M J; Reis, M

    2014-11-01

    A method based on the separation of Sr-90 by extraction chromatography and beta determination by Liquid Scintillation Counting (LSC) technique was used for strontium analysis in food samples. The methodology consisted in prior sample treatment (drying and incineration) followed by radiochemical separation of Sr-90 by extraction chromatography, using the Sr-resin. The chemical yield was determined by gravimetric method, adding stable strontium to the matrix. Beta activity (Sr-90/Y-90) was determined using a low background liquid scintillation spectrometer (Tri-Carb 3170 TR/SL, Packard). The accuracy and the precision of the method, was performed previously through recovery trials with Sr-90 spiked samples, using the same type of matrices (milk, complete meals, meat and vegetables). A reference material (IAEA_321) was now used to measure the accuracy of the procedure. Participation in interlaboratory comparison exercises was also performed in order to establish an external control on the measurements and to ensure the adequacy of the method. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Determination of specific activity of cobalt (60Co/Co) in steel samples exposed to the atomic bomb in Hiroshima.

    PubMed

    Kimura, T; Takano, N; Iba, T; Fujita, S; Watanabe, T; Maruyama, T; Hamada, T

    1990-06-01

    Specific activity 60Co/Co in two steel samples taken at 687m S and 1295m NNW from the hypocenter was measured by gamma-ray spectrometry and neutron activation analysis. The results were, respectively, (2.64 +/- 0.38) x 10(1) and (3.09 +/- 0.48) x 10(-1) dpm/mg Co at the time of bombing, which are consistent with previous data by Hashizume et al. for steel rings on the surface of roofs of buildings. The present data are expected to serve as verification of the bomb neutron transport calculations. Content of nickel and copper in the samples, determined by colorimetric and neutron activation methods, respectively, was too small to account for any significant 60Co production by the (n,p) and (n, alpha) reactions.

  13. Method of multivariate spectral analysis

    DOEpatents

    Keenan, Michael R.; Kotula, Paul G.

    2004-01-06

    A method of determining the properties of a sample from measured spectral data collected from the sample by performing a multivariate spectral analysis. The method can include: generating a two-dimensional matrix A containing measured spectral data; providing a weighted spectral data matrix D by performing a weighting operation on matrix A; factoring D into the product of two matrices, C and S.sup.T, by performing a constrained alternating least-squares analysis of D=CS.sup.T, where C is a concentration intensity matrix and S is a spectral shapes matrix; unweighting C and S by applying the inverse of the weighting used previously; and determining the properties of the sample by inspecting C and S. This method can be used to analyze X-ray spectral data generated by operating a Scanning Electron Microscope (SEM) with an attached Energy Dispersive Spectrometer (EDS).

  14. Predominant bacteria in an activated sludge reactor for the degradation of cutting fluids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, C.A.; Claus, G.W.; Taylor, P.A.

    1983-01-01

    For the first time, an activated sludge reactor, established for the degradation of cutting fluids, was examined for predominant bacteria. In addition, both total and viable numbers of bacteria in the reactor were determined so that the percentage of each predominant type in the total reactor population could be determined. Three samples were studied, and a total of 15 genera were detected. In each sample, the genus Pseudomonas and the genus Microcyclus were present in high numbers. Three other genera, Acinetobacter, Alcaligenes, and Corynebacterium, were also found in every sample but in lower numbers. In one sample, numerous appendage bacteriamore » were present, and one of these, the genus Seliberia, was the most predominant organism in that sample. However, in the other two samples no appendage bacteria were detected. Six genera were found in this reactor which have not been previously reported in either cutting fluids in use or in other activated sludge systems. These genera were Aeromonas, Hyphomonas, Listeria, Microcyclus, Moraxella, and Spirosoma. None of the predominant bacterial belonged to groups of strict pathogens. 22 references, 6 figures, 3 tables.« less

  15. Validity of strong lensing statistics for constraints on the galaxy evolution model

    NASA Astrophysics Data System (ADS)

    Matsumoto, Akiko; Futamase, Toshifumi

    2008-02-01

    We examine the usefulness of the strong lensing statistics to constrain the evolution of the number density of lensing galaxies by adopting the values of the cosmological parameters determined by recent Wilkinson Microwave Anisotropy Probe observation. For this purpose, we employ the lens-redshift test proposed by Kochanek and constrain the parameters in two evolution models, simple power-law model characterized by the power-law indexes νn and νv, and the evolution model by Mitchell et al. based on cold dark matter structure formation scenario. We use the well-defined lens sample from the Sloan Digital Sky Survey (SDSS) and this is similarly sized samples used in the previous studies. Furthermore, we adopt the velocity dispersion function of early-type galaxies based on SDSS DR1 and DR5. It turns out that the indexes of power-law model are consistent with the previous studies, thus our results indicate the mild evolution in the number and velocity dispersion of early-type galaxies out to z = 1. However, we found that the values for p and q used by Mitchell et al. are inconsistent with the presently available observational data. More complete sample is necessary to withdraw more realistic determination on these parameters.

  16. Voltammetric determination of arsenic in high iron and manganese groundwaters.

    PubMed

    Gibbon-Walsh, Kristoff; Salaün, Pascal; Uroic, M Kalle; Feldmann, Joerg; McArthur, John M; van den Berg, Constant M G

    2011-09-15

    Determination of the speciation of arsenic in groundwaters, using cathodic stripping voltammetry (CSV), is severely hampered by high levels of iron and manganese. Experiments showed that the interference is eliminated by addition of EDTA, making it possible to determine the arsenic speciation on-site by CSV. This work presents the CSV method to determine As(III) in high-iron or -manganese groundwaters in the field with only minor sample treatment. The method was field-tested in West-Bengal (India) on a series of groundwater samples. Total arsenic was subsequently determined after acidification to pH 1 by anodic stripping voltammetry (ASV). Comparative measurements by ICP-MS as reference method for total As, and by HPLC for its speciation, were used to corroborate the field data in stored samples. Most of the arsenic (78±0.02%) was found to occur as inorganic As(III) in the freshly collected waters, in accordance with previous studies. The data shows that the modified on-site CSV method for As(III) is a good measure of water contamination with As. The EDTA was also found to be effective in stabilising the arsenic speciation for longterm sample storage at room temperature. Without sample preservation, in water exposed to air and sunlight, the As(III) was found to become oxidised to As(V), and Fe(II) oxidised to Fe(III), removing the As(V) by adsorption on precipitating Fe(III)-hydroxides within a few hours. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. RECOMMENDATIONS FOR SAMPLING OF TANK 19 IN F TANK FARM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, S.; Shine, G.

    2009-12-14

    Representative sampling is required for characterization of the residual material in Tank 19 prior to operational closure. Tank 19 is a Type IV underground waste storage tank located in the F-Tank Farm. It is a cylindrical-shaped, carbon steel tank with a diameter of 85 feet, a height of 34.25 feet, and a working capacity of 1.3 million gallons. Tank 19 was placed in service in 1961 and initially received a small amount of low heat waste from Tank 17. It then served as an evaporator concentrate (saltcake) receiver from February 1962 to September 1976. Tank 19 also received the spentmore » zeolite ion exchange media from a cesium removal column that once operated in the Northeast riser of the tank to remove cesium from the evaporator overheads. Recent mechanical cleaning of the tank removed all mounds of material. Anticipating a low level of solids in the residual waste, Huff and Thaxton [2009] developed a plan to sample the waste during the final clean-up process while it would still be resident in sufficient quantities to support analytical determinations in four quadrants of the tank. Execution of the plan produced fewer solids than expected to support analytical determinations in all four quadrants. Huff and Thaxton [2009] then restructured the plan to characterize the residual separately in the North and the South regions: two 'hemispheres.' This document provides sampling recommendations to complete the characterization of the residual material on the tank bottom following the guidance in Huff and Thaxton [2009] to split the tank floor into a North and a South hemisphere. The number of samples is determined from a modification of the formula previously published in Edwards [2001] and the sample characterization data for previous sampling of Tank 19 described by Oji [2009]. The uncertainty is quantified by an upper 95% confidence limit (UCL95%) on each analyte's mean concentration in Tank 19. The procedure computes the uncertainty in analyte concentration as a function of the number of samples, and the final number of samples is determined when the reduction in the uncertainty from an additional sample no longer has a practical impact on results. The characterization of the full suite of analytes in the North and South hemispheres is currently supported by a single Mantis rover sample in each hemisphere. A floor scrape sample was obtained from a compact region near the center riser slightly in the South hemisphere and has been analyzed for a shortened list of key analytes. There is not enough additional material from the floor scrape sample material for completing the full suite of constituents. No floor scrape samples have been previously taken from the North hemisphere. The criterion to determine the number of additional samples was based on the practical reduction in the uncertainty when a new sample is added. This was achieved when five additional samples are obtained. In addition, two archived samples will be used if a contingency such as failing to demonstrate the comparability of the Mantis samples to the floor scrape samples occurs. To complete sampling of the Tank 19 residual floor material, four additional samples should be taken from the North hemisphere and four additional samples should be taken from the South hemisphere. One of the samples from each hemisphere will be archived in case of need. Three of the four additional samples from each hemisphere will be analyzed. Once the results are available, differences between the Mantis and three floor scrape sample results will be evaluated. If there are no statistically significant analyte concentration differences between the Mantis and floor scrape samples, those results will be combined and then UCL95%s will be calculated. If the analyte concentration differences between the Mantis and floor scrape samples are statistically significant, the UCL95%s will be calculated without the Mantis sample results. If further reduction in the upper confidence limits is needed and can be achieved by the addition of the archived samples, they will be analyzed and included in the statistical computations. Initially the analyte concentrations in the residual material on the floor of Tank 19 will be determined separately in the North and the South hemispheres. However, if final sampling results show that differences between the North and South samples are consistent within sampling variation, then the final computations can be based on consolidating all sample results from the tank floor. Recommended locations may be subject to physical tank access and sampling constraints for the additional samples. The recommendations have been discussed in Section 4 and are based on partitioning the Tank 19 floor into an inner and an outer ring and six 60{sup o} sectors depicted in Figure 1. The location of the border between the inner and outer rings is based on dividing the residual material into two approximately equal volumes.« less

  18. Coach-Initiated Motivational Climate and Cohesion in Youth Sport

    ERIC Educational Resources Information Center

    Eys, Mark A.; Jewitt, Eryn; Evans, M. Blair; Wolf, Svenja; Bruner, Mark W.; Loughead, Todd M.

    2013-01-01

    Purpose: The general purpose of the present study was to examine the link between cohesion and motivational climate in youth sport. The first specific objective was to determine if relationships demonstrated in previous research with adult basketball and handball participants would be replicated in a younger sample and with a more heterogeneous…

  19. Confirmatory Factor Analysis of the WISC-IV in a Hospital Referral Sample

    ERIC Educational Resources Information Center

    Devena, Sarah E.; Gay, Catherine E.; Watkins, Marley W.

    2013-01-01

    Confirmatory factor analysis was used to determine the factor structure of the Wechsler Intelligence Scale for Children-Fourth Edition (WISC-IV) scores of 297 children referred to a children's hospital in the Southwestern United States. Results support previous findings that indicate the WISC-IV is best represented by a direct hierarchical…

  20. The application of nirvana to silvicultural studies

    Treesearch

    Chi-Leung So; Thomas Elder; Leslie Groom; John S. Kush; Jennifer Myszewski; Todd Shupe

    2006-01-01

    Previous results from this laboratory have shown that near infrared (NIR) spectroscopy, coupled with multivariate analysis, can be a powerful tool for the prediction of wood quality. While wood quality measurements are of utility, their determination can be both time and labor intensive, thus limiting their use where large sample sizes are concerned. This paper will...

  1. Recommendations for representative ballast water sampling

    NASA Astrophysics Data System (ADS)

    Gollasch, Stephan; David, Matej

    2017-05-01

    Until now, the purpose of ballast water sampling studies was predominantly limited to general scientific interest to determine the variety of species arriving in ballast water in a recipient port. Knowing the variety of species arriving in ballast water also contributes to the assessment of relative species introduction vector importance. Further, some sampling campaigns addressed awareness raising or the determination of organism numbers per water volume to evaluate the species introduction risk by analysing the propagule pressure of species. A new aspect of ballast water sampling, which this contribution addresses, is compliance monitoring and enforcement of ballast water management standards as set by, e.g., the IMO Ballast Water Management Convention. To achieve this, sampling methods which result in representative ballast water samples are essential. We recommend such methods based on practical tests conducted on two commercial vessels also considering results from our previous studies. The results show that different sampling approaches influence the results regarding viable organism concentrations in ballast water samples. It was observed that the sampling duration (i.e., length of the sampling process), timing (i.e., in which point in time of the discharge the sample is taken), the number of samples and the sampled water quantity are the main factors influencing the concentrations of viable organisms in a ballast water sample. Based on our findings we provide recommendations for representative ballast water sampling.

  2. The Near-infrared Optimal Distances Method Applied to Galactic Classical Cepheids Tightly Constrains Mid-infrared Period–Luminosity Relations

    NASA Astrophysics Data System (ADS)

    Wang, Shu; Chen, Xiaodian; de Grijs, Richard; Deng, Licai

    2018-01-01

    Classical Cepheids are well-known and widely used distance indicators. As distance and extinction are usually degenerate, it is important to develop suitable methods to robustly anchor the distance scale. Here, we introduce a near-infrared optimal distance method to determine both the extinction values of and distances to a large sample of 288 Galactic classical Cepheids. The overall uncertainty in the derived distances is less than 4.9%. We compare our newly determined distances to the Cepheids in our sample with previously published distances to the same Cepheids with Hubble Space Telescope parallax measurements and distances based on the IR surface brightness method, Wesenheit functions, and the main-sequence fitting method. The systematic deviations in the distances determined here with respect to those of previous publications is less than 1%–2%. Hence, we constructed Galactic mid-IR period–luminosity (PL) relations for classical Cepheids in the four Wide-Field Infrared Survey Explorer (WISE) bands (W1, W2, W3, and W4) and the four Spitzer Space Telescope bands ([3.6], [4.5], [5.8], and [8.0]). Based on our sample of hundreds of Cepheids, the WISE PL relations have been determined for the first time; their dispersion is approximately 0.10 mag. Using the currently most complete sample, our Spitzer PL relations represent a significant improvement in accuracy, especially in the [3.6] band which has the smallest dispersion (0.066 mag). In addition, the average mid-IR extinction curve for Cepheids has been obtained: {A}W1/{A}{K{{s}}}≈ 0.560, {A}W2/{A}{K{{s}}}≈ 0.479, {A}W3/{A}{K{{s}}}≈ 0.507, {A}W4/{A}{K{{s}}}≈ 0.406, {A}[3.6]/{A}{K{{s}}}≈ 0.481, {A}[4.5]/{A}{K{{s}}}≈ 0.469, {A}[5.8]/{A}{K{{s}}}≈ 0.427, and {A}[8.0]/{A}{K{{s}}}≈ 0.427 {mag}.

  3. Determination of HIV Status in African Adults With Discordant HIV Rapid Tests.

    PubMed

    Fogel, Jessica M; Piwowar-Manning, Estelle; Donohue, Kelsey; Cummings, Vanessa; Marzinke, Mark A; Clarke, William; Breaud, Autumn; Fiamma, Agnès; Donnell, Deborah; Kulich, Michal; Mbwambo, Jessie K K; Richter, Linda; Gray, Glenda; Sweat, Michael; Coates, Thomas J; Eshleman, Susan H

    2015-08-01

    In resource-limited settings, HIV infection is often diagnosed using 2 rapid tests. If the results are discordant, a third tie-breaker test is often used to determine HIV status. This study characterized samples with discordant rapid tests and compared different testing strategies for determining HIV status in these cases. Samples were previously collected from 173 African adults in a population-based survey who had discordant rapid test results. Samples were classified as HIV positive or HIV negative using a rigorous testing algorithm that included two fourth-generation tests, a discriminatory test, and 2 HIV RNA tests. Tie-breaker tests were evaluated, including rapid tests (1 performed in-country), a third-generation enzyme immunoassay, and two fourth-generation tests. Selected samples were further characterized using additional assays. Twenty-nine samples (16.8%) were classified as HIV positive and 24 of those samples (82.8%) had undetectable HIV RNA. Antiretroviral drugs were detected in 1 sample. Sensitivity was 8.3%-43% for the rapid tests; 24.1% for the third-generation enzyme immunoassay; 95.8% and 96.6% for the fourth-generation tests. Specificity was lower for the fourth-generation tests than the other tests. Accuracy ranged from 79.5% to 91.3%. In this population-based survey, most HIV-infected adults with discordant rapid tests were virally suppressed without antiretroviral drugs. Use of individual assays as tie-breaker tests was not a reliable method for determining HIV status in these individuals. More extensive testing algorithms that use a fourth-generation screening test with a discriminatory test and HIV RNA test are preferable for determining HIV status in these cases.

  4. Discrimination of almonds (Prunus dulcis) geographical origin by minerals and fatty acids profiling.

    PubMed

    Amorello, Diana; Orecchio, Santino; Pace, Andrea; Barreca, Salvatore

    2016-09-01

    Twenty-one almond samples from three different geographical origins (Sicily, Spain and California) were investigated by determining minerals and fatty acids compositions. Data were used to discriminate by chemometry almond origin by linear discriminant analysis. With respect to previous PCA profiling studies, this work provides a simpler analytical protocol for the identification of almonds geographical origin. Classification by using mineral contents data only was correct in 77% of the samples, while, by using fatty acid profiles, the percentages of samples correctly classified reached 82%. The coupling of mineral contents and fatty acid profiles lead to an increased efficiency of the classification with 87% of samples correctly classified.

  5. Raman-spectroscopy-based chemical contaminant detection in milk powder

    NASA Astrophysics Data System (ADS)

    Dhakal, Sagar; Chao, Kuanglin; Qin, Jianwei; Kim, Moon S.

    2015-05-01

    Addition of edible and inedible chemical contaminants in food powders for purposes of economic benefit has become a recurring trend. In recent years, severe health issues have been reported due to consumption of food powders contaminated with chemical substances. This study examines the effect of spatial resolution used during spectral collection to select the optimal spatial resolution for detecting melamine in milk powder. Sample depth of 2mm, laser intensity of 200mw, and exposure time of 0.1s were previously determined as optimal experimental parameters for Raman imaging. Spatial resolution of 0.25mm was determined as the optimal resolution for acquiring spectral signal of melamine particles from a milk-melamine mixture sample. Using the optimal resolution of 0.25mm, sample depth of 2mm and laser intensity of 200mw obtained from previous study, spectral signal from 5 different concentration of milk-melamine mixture (1%, 0.5%, 0.1%, 0.05%, and 0.025%) were acquired to study the relationship between number of detected melamine pixels and corresponding sample concentration. The result shows that melamine concentration has a linear relation with detected number of melamine pixels with correlation coefficient of 0.99. It can be concluded that the quantitative analysis of powder mixture is dependent on many factors including physical characteristics of mixture, experimental parameters, and sample depth. The results obtained in this study are promising. We plan to apply the result obtained from this study to develop quantitative detection model for rapid screening of melamine in milk powder. This methodology can also be used for detection of other chemical contaminants in milk powders.

  6. Rapid Multiplex PCR Assay To Identify Respiratory Viral Pathogens: Moving Forward Diagnosing The Common Cold

    PubMed Central

    Gordon, Sarah M; Elegino-Steffens, Diane U; Agee, Willie; Barnhill, Jason; Hsue, Gunther

    2013-01-01

    Upper respiratory tract infections (URIs) can be a serious burden to the healthcare system. The majority of URIs are viral in etiology, but definitive diagnosis can prove difficult due to frequently overlapping clinical presentations of viral and bacterial infections, and the variable sensitivity, and lengthy turn-around time of viral culture. We tested new automated nested multiplex PCR technology, the FilmArray® system, in the TAMC department of clinical investigations, to determine the feasibility of replacing the standard viral culture with a rapid turn-around system. We conducted a feasibility study using a single-blinded comparison study, comparing PCR results with archived viral culture results from a convenience sample of cryopreserved archived nasopharyngeal swabs from acutely ill ED patients who presented with complaints of URI symptoms. A total of 61 archived samples were processed. Viral culture had previously identified 31 positive specimens from these samples. The automated nested multiplex PCR detected 38 positive samples. In total, PCR was 94.5% concordant with the previously positive viral culture results. However, PCR was only 63.4% concordant with the negative viral culture results, owing to PCR detection of 11 additional viral pathogens not recovered on viral culture. The average time to process a sample was 75 minutes. We determined that an automated nested multiplex PCR is a feasible alternative to viral culture in an acute clinical setting. We were able to detect at least 94.5% as many viral pathogens as viral culture is able to identify, with a faster turn-around time. PMID:24052914

  7. Feasibility study of TSPO quantification with [18F]FEPPA using population-based input function.

    PubMed

    Mabrouk, Rostom; Strafella, Antonio P; Knezevic, Dunja; Ghadery, Christine; Mizrahi, Romina; Gharehgazlou, Avideh; Koshimori, Yuko; Houle, Sylvain; Rusjan, Pablo

    2017-01-01

    The input function (IF) is a core element in the quantification of Translocator protein 18 kDa with positron emission tomography (PET), as no suitable reference region with negligible binding has been identified. Arterial blood sampling is indeed needed to create the IF (ASIF). In the present manuscript we study individualization of a population based input function (PBIF) with a single arterial manual sample to estimate total distribution volume (VT) for [18F]FEPPA and to replicate previously published clinical studies in which the ASIF was used. The data of 3 previous [18F]FEPPA studies (39 of healthy controls (HC), 16 patients with Parkinson's disease (PD) and 18 with Alzheimer's disease (AD)) was reanalyzed with the new approach. PBIF was used with the Logan graphical analysis (GA) neglecting the vascular contribution to estimate VT. Time of linearization of the GA was determined with the maximum error criteria. The optimal calibration of the PBIF was determined based on the area under the curve (AUC) of the IF and the agreement range of VT between methods. The shape of the IF between groups was studied while taking into account genotyping of the polymorphism (rs6971). PBIF scaled with a single value of activity due to unmetabolized radioligand in arterial plasma, calculated as the average of a sample taken at 60 min and a sample taken at 90 min post-injection, yielded a good interval of agreement between methods and optimized the area under the curve of IF. In HC, gray matter VTs estimated by PBIF highly correlated with those using the standard method (r2 = 0.82, p = 0.0001). Bland-Altman plots revealed PBIF slightly underestimates (~1 mL/cm3) VT calculated by ASIF (including a vascular contribution). It was verified that the AUC of the ASIF were independent of genotype and disease (HC, PD, and AD). Previous clinical results were replicated using PBIF but with lower statistical power. A single arterial blood sample taken 75 minute post-injection contains enough information to individualize the IF in the groups of subjects studied; however, the higher variability produced requires an increase in sample size to reach the same effect size.

  8. Point of data saturation was assessed using resampling methods in a survey with open-ended questions.

    PubMed

    Tran, Viet-Thi; Porcher, Raphael; Falissard, Bruno; Ravaud, Philippe

    2016-12-01

    To describe methods to determine sample sizes in surveys using open-ended questions and to assess how resampling methods can be used to determine data saturation in these surveys. We searched the literature for surveys with open-ended questions and assessed the methods used to determine sample size in 100 studies selected at random. Then, we used Monte Carlo simulations on data from a previous study on the burden of treatment to assess the probability of identifying new themes as a function of the number of patients recruited. In the literature, 85% of researchers used a convenience sample, with a median size of 167 participants (interquartile range [IQR] = 69-406). In our simulation study, the probability of identifying at least one new theme for the next included subject was 32%, 24%, and 12% after the inclusion of 30, 50, and 100 subjects, respectively. The inclusion of 150 participants at random resulted in the identification of 92% themes (IQR = 91-93%) identified in the original study. In our study, data saturation was most certainly reached for samples >150 participants. Our method may be used to determine when to continue the study to find new themes or stop because of futility. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Multicommuted flow system for the determination of glucose in animal blood serum exploiting enzymatic reaction and chemiluminescence detection

    PubMed Central

    Pires, Cherrine K.; Martelli, Patrícia B.; Lima, José L. F. C.; Saraiva, Maria Lúcia M. F. S.

    2003-01-01

    An automatic flow procedure based on multicommutation dedicated for the determination of glucose in animal blood serum using glucose oxidase with chemiluminescence detection is described. The flow manifold consisted of a set of three-way solenoid valves assembled to implement multicommutation. A microcomputer furnished with an electronic interface and software written in Quick BASIC 4.5 controlled the manifold and performed data acquisition. Glucose oxidase was immobilized on porous silica beads (glass aminopropyl) and packed in a minicolumn (15 × 5 mm). The procedure was based on the enzymatic degradation of glucose, producing hydrogen peroxide, which oxidized luminol in the presence of hexacyanoferrate(III), causing the chemiluminescence. The system was tested by analysing a set of serum animal samples without previous treatment. Results were in agreement with those obtained with the conventional method (LABTEST Kit) at the 95% confidence level. The detection limit and variation coefficient were estimated as 12.0 mg l−1 (99.7% confidence level) and 3.5% (n = 20), respectively. The sampling rate was about 60 determinations h−1 with sample concentrations ranging from 50 to 600 mg l−1 glucose. The consumptions of serum sample, hexacyanoferrate(III) and luminol were 46 μl, 10.0 mg and 0.2 mg/determination, respectively. PMID:18924619

  10. Effects of Holding Time, Storage, and the Preservation of ...

    EPA Pesticide Factsheets

    The purpose of this project was to answer questions related to storage of samples to be analyzed by the quantitative polymerase chain reaction (qPCR)-based assays for fecal indicator bacteria. The project was divided into two parts. The first part was to determine if filters that were used to collect fecal indicators could be stored frozen and analyzed at a later date and the second part was to determine if refrigerated water samples could be held for 24 to 48 hours prior to analysis by qPCR. Both of these studies answer questions that were important in the analysis of fresh and marine surface water samples for beach monitoring purposes. 1) Develop and evaluate qPCR assays and test methods for the detection and quantification of genetic markers from indicator bacteria that are associated with human fecal waste and from two new groups of general fecal indicator bacteria (E. coli and Clostridia) that historically have been widely used or are favored in specific regions 2) Determine the occurrence and densities of genetic markers detected by new qPCR assays developed under objective 1 and compare with occurrence and densities of genetic markers detected by previously developed qPCR assays for enterococci and total Bacterioidalesin waste waters and fecal material from different animal sources. 3) Determine stability of fecal indicator bacteria target DNA sequences in freezer archived filter retentates of ambient surface water samples 4) Determine the densitie

  11. Validation of mega composite sampling and nationwide mass inventories for 26 previously unmonitored contaminants in archived biosolids from the U.S National Biosolids Repository

    PubMed Central

    Chari, Bipin P.; Halden, Rolf U.

    2012-01-01

    In the present study, archived U.S biosolids from the 2001 Environmental Protection Agency (EPA) National Sewage Sludge Survey were analyzed with an expanded U.S EPA Method 1694, to determine the occurrence of 26 previously unmonitored pharmaceuticals and personal care products (PPCPs) among a total of 120 analytes. The study further served to examine the reproducibility of a mega-composite approach for creating chemical mass inventories in biosolids based on pooled samples from wastewater treatment plants (WWTPs) nationwide. Five mega-composites reflecting 94 WWTPs in 32 states and the District of Columbia were constructed from archived biosolids and analyzed by LC/ESI-MS/MS using a newly introduced analytical method expanding upon U.S EPA Method 1694. In addition, soil-biosolids mixtures from a mesocosm setup were analyzed to experimentally determine the half-lives of biosolids-borne compounds applied on U.S land. Among 59 analytes detected, 33 had been reported previously, whereas 26 are reported in biosolids for the first time, at levels ranging from 1.65 to 673 μg kg−1 dry weight. Newly recognized biosolids constituents were identified as Ca2+ channel blockers, antidepressants, diuretics, β-blockers and analgesics. Using a mass balance approach, the total loading of these 26 pharmaceuticals to U.S soils from biosolids land application was estimated at 5–15 tons year−1. Past and present datasets for 30 pharmaceuticals and personal care products (PPCPs) were determined to be statistically indistinguishable (paired t-test; p = 0.01). This study expands the list of PPCPs reported in U.S biosolids, provides the first estimates of nationwide release rates to and environmental half-lives in U.S agricultural soils, and confirms the utility of using mega-composite sampling for economical tracking of chemical inventories in biosolids on a national scale. PMID:22789759

  12. Determination of methylmercury and inorganic mercury in water samples by slurry sampling cold vapor atomic absorption spectrometry in a flow injection system after preconcentration on silica C(18) modified.

    PubMed

    Segade, Susana Río; Tyson, Julian F

    2007-03-15

    A novel method for preconcentration of methylmercury and inorganic mercury from water samples was developed involving the determination of ngl(-1) levels of analytes retained on the silica C(18) solid sorbent, previous complexation with ammonium pyrrolidine dithiocarbamate (APDC), by slurry sampling cold vapor atomic absorption spectrometry (SS-CVAAS) in a flow injection (FI) system. Several variables were optimized affecting either the retention of both mercury species, such as APDC concentration, silica C(18) amount, agitation times, or their determination, including hydrochloric acid concentration in the suspension medium, peristaltic pump speed and argon flow-rate. A Plackett-Burman saturated factorial design permitted to differentiate the influential parameters on the preconcentration efficiency, which were after optimized by the sequential simplex method. The contact time between mercury containing solution and APDC, required to reach an efficient sorption, was decreased from 26 to 3min by the use of sonication stirring instead of magnetic stirring. The use of 1moldm(-3) hydrochloric acid suspension medium and 0.75% (m/v) sodium borohydride reducing agent permitted the selective determination of methylmercury. The combination of 5moldm(-3) hydrochloric acid and 10(-4)% (m/v) sodium borohydride was used for the selective determination of inorganic mercury. The detection limits achieved for methylmercury and inorganic mercury determination under optimum conditions were 0.96 and 0.25ngl(-1), respectively. The reliability of the proposed method for the determination of both mercury species in waters was checked by the analysis of samples spiked with known concentrations of methylmercury and inorganic mercury; quantitative recoveries were obtained.

  13. Blood transport method for chromosome analysis of residents living near Semipalatinsk nuclear test site.

    PubMed

    Rodzi, Mohd; Ihda, Shozo; Yokozeki, Masako; Takeichi, Nobuo; Tanaka, Kimio; Hoshi, Masaharu

    2009-12-01

    A study was conducted to compare the storage conditions and transportation period for blood samples collected from residents living in areas near the Semipalatinsk nuclear test site (SNTS). Experiments were performed to simulate storage and shipping environments. Phytohaemagglutinin (PHA)-stimulated blood was stored in 15-ml tubes (condition A: current transport method) in the absence or in 50-ml flasks (condition B: previous transport method) in the presence of RPMI-1640 and 20% fetal bovine serum (FBS). Samples were kept refrigerated at 4 degrees C and cell viability was assessed after 3, 8, 12 and 14 days of storage. RPMI-1640, 20% FBS and further PHA were added to blood samples under condition A in 50-ml flasks for culture. Whole-blood samples under condition B were directly incubated without further sub-culturing process, neither media nor PHA were added, to adopt a similar protocol to that employed in the previous transport method. Samples in condition A and condition B were incubated for 48 hr at 37 degrees C and their mitotic index was determined. The results showed that viable lymphocytes were consistent in both storage conditions but the mitotic index was higher in condition A than in condition B. Although further confirmation studies have to be carried out, previous chromosomal studies and the present experiment have shown that PHA-stimulated blood could be stored without culture medium for up to 8 days under condition A. The present results will be useful for cytogenetic analysis of blood samples that have been transported long distances wherever a radiation accident has occurred.

  14. Fragmentation of contaminant and endogenous DNA in ancient samples determined by shotgun sequencing; prospects for human palaeogenomics.

    PubMed

    García-Garcerà, Marc; Gigli, Elena; Sanchez-Quinto, Federico; Ramirez, Oscar; Calafell, Francesc; Civit, Sergi; Lalueza-Fox, Carles

    2011-01-01

    Despite the successful retrieval of genomes from past remains, the prospects for human palaeogenomics remain unclear because of the difficulty of distinguishing contaminant from endogenous DNA sequences. Previous sequence data generated on high-throughput sequencing platforms indicate that fragmentation of ancient DNA sequences is a characteristic trait primarily arising due to depurination processes that create abasic sites leading to DNA breaks. METHODOLOGY/PRINCIPALS FINDINGS: To investigate whether this pattern is present in ancient remains from a temperate environment, we have 454-FLX pyrosequenced different samples dated between 5,500 and 49,000 years ago: a bone from an extinct goat (Myotragus balearicus) that was treated with a depurinating agent (bleach), an Iberian lynx bone not subjected to any treatment, a human Neolithic sample from Barcelona (Spain), and a Neandertal sample from the El Sidrón site (Asturias, Spain). The efficiency of retrieval of endogenous sequences is below 1% in all cases. We have used the non-human samples to identify human sequences (0.35 and 1.4%, respectively), that we positively know are contaminants. We observed that bleach treatment appears to create a depurination-associated fragmentation pattern in resulting contaminant sequences that is indistinguishable from previously described endogenous sequences. Furthermore, the nucleotide composition pattern observed in 5' and 3' ends of contaminant sequences is much more complex than the flat pattern previously described in some Neandertal contaminants. Although much research on samples with known contaminant histories is needed, our results suggest that endogenous and contaminant sequences cannot be distinguished by the fragmentation pattern alone.

  15. Snow cover monitoring by machine processing of multitemporal LANDSAT MSS data

    NASA Technical Reports Server (NTRS)

    Luther, S. G.; Bartolucci, L. A.; Hoffer, R. M.

    1975-01-01

    LANDSAT frames were geometrically corrected and data sets from six different dates were overlaid to produce a 24 channel (six dates and four wavelength bands) data tape. Changes in the extent of the snowpack could be accurately and easily determined using a change detection technique on data which had previously been classified by the LARSYS software system. A second phase of the analysis involved determination of the relationship between spatial resolution or data sampling frequency and accuracy of measuring the area of the snowpack.

  16. Electropyroelectric technique: A methodology free of fitting procedures for thermal effusivity determination in liquids.

    PubMed

    Ivanov, R; Marin, E; Villa, J; Gonzalez, E; Rodríguez, C I; Olvera, J E

    2015-06-01

    This paper describes an alternative methodology to determine the thermal effusivity of a liquid sample using the recently proposed electropyroelectric technique, without fitting the experimental data with a theoretical model and without having to know the pyroelectric sensor related parameters, as in most previous reported approaches. The method is not absolute, because a reference liquid with known thermal properties is needed. Experiments have been performed that demonstrate the high reliability and accuracy of the method with measurement uncertainties smaller than 3%.

  17. Extraction, -scrub, -strip test results from the interim salt disposition program macrobatch 10 tank 21H qualification samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, T. B.

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 10 for the Interim Salt Disposition Program (ISDP). The Salt Batch 10 characterization results were previously reported.ii,iii An Extraction, -Scrub, -Strip (ESS) test was performed to determine cesium distribution ratios (D(Cs)) and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Tank Farm Engineering to project a cesium decontamination factor (DF). This test used actual Tank 21H material, and a sample of the NGS Blend solvent currently being used at the Modularmore » Caustic-Side Solvent Extraction Unit (MCU). The ESS test showed acceptable performance with an extraction D(Cs) value of 110. This value is consistent with results from previous salt batch ESS tests using similar solvent formulations. This is better than the predicted value of 39.8 from a recently created D(Cs) model.« less

  18. Late Quaternary offset of alluvial fan surfaces along the Central Sierra Madre Fault, southern California

    USGS Publications Warehouse

    Burgette, Reed J.; Hanson, Austin; Scharer, Katherine M.; Midttun, Nikolas

    2016-01-01

    The Sierra Madre Fault is a reverse fault system along the southern flank of the San Gabriel Mountains near Los Angeles, California. This study focuses on the Central Sierra Madre Fault (CSMF) in an effort to provide numeric dating on surfaces with ages previously estimated from soil development alone. We have refined previous geomorphic mapping conducted in the western portion of the CSMF near Pasadena, CA, with the aid of new lidar data. This progress report focuses on our geochronology strategy employed in collecting samples and interpreting data to determine a robust suite of terrace surface ages. Sample sites for terrestrial cosmogenic nuclide and luminescence dating techniques were selected to be redundant and to be validated through relative geomorphic relationships between inset terrace levels. Additional sample sites were selected to evaluate the post-abandonment histories of terrace surfaces. We will combine lidar-derived displacement data with surface ages to estimate slip rates for the CSMF.

  19. Genus-specific PCR Primers Targeting Intracellular Parasite Euduboscquella (Dinoflagellata: Syndinea)

    NASA Astrophysics Data System (ADS)

    Jung, Jae-Ho; Choi, Jung Min; Kim, Young-Ok

    2018-03-01

    We designed a genus-specific primer pair targeting the intracellular parasite Euduboscquella. To increase target specificity and inhibit untargeted PCR, two nucleotides were added at the 3' end of the reverse primer, one being a complementary nucleotide to the Euduboscquella-specific SNP (single-nucleotide polymorphism) and the other a deliberately mismatched nucleotide. Target specificity of the primer set was verified experimentally using PCR of two Euduboscquella species (positive controls) and 15 related species (negative controls composed of ciliates, diatoms and dinoflagellates), and analytical comparison with SILVA SSU rRNA gene database (release 119) in silico. In addition, we applied the Euduboscquella-specific primer set to four environmental samples previously determined by cytological staining to be either positive or negative for Euduboscquella. As expected, only positive controls and environmental samples known to contain Euduboscquella were successfully amplified by the primer set. An inferred SSU rRNA gene phylogeny placed environmental samples containing aloricate ciliates infected by Euduboscquella in a cluster discrete from Euduboscquella groups a-d previously reported from loricate, tintinnid ciliates.

  20. Accuracy and usefulness of the AVOXimeter 4000 as routine analysis of carboxyhemoglobin.

    PubMed

    Fujihara, Junko; Kinoshita, Hiroshi; Tanaka, Naoko; Yasuda, Toshihiro; Takeshita, Haruo

    2013-07-01

    The measurement of blood carboxyhemoglobin (CO-Hb) is important to determine the cause of death. The AVOXimeter 4000 (AVOX), a portable CO-oximeter, has the advantages of a low purchase price and operating cost, ease of operation, and rapid results. Little information is available on the usefulness of AVOX in the forensic sample, and the previous study investigated only six samples. Therefore, in this study, we confirmed the usefulness of the AVOX through a comparison of its results with data previously obtained using the double wavelength spectrophotometric method in autopsies. Regression analysis was performed between CO-Hb levels measured by the AVOX and those measured by the conventional double wavelength spectrophotometric method in postmortem blood samples: a significant correlation was observed. This study suggests the usefulness of the AVOX to analyze postmortem blood, and the AVOX is suitable for routine forensic analysis and can be applied at the crime scene. © 2013 American Academy of Forensic Sciences.

  1. The quality of feeding assistance care practices for long-term care veterans: implications for quality improvement efforts.

    PubMed

    Simmons, Sandra F; Sims, Nichole; Durkin, Daniel W; Shotwell, Matthew S; Erwin, Scott; Schnelle, John F

    2013-09-01

    The primary purpose of this study was to determine the quality of feeding assistance care and identify areas in need of improvement for a sample of long-term care veterans. A secondary purpose was to compare these findings with the results of previous studies in community facilities to determine ways in which the VA sample might differ. A repeated measures observational study was conducted in two VA facilities with 200 long-stay residents. Research staff conducted standardized observations during and between meals for 3 months. There was a trend for better feeding assistance care quality during meals in the VA sample, but there were still multiple aspects of care in need of improvement both during and between meals. Higher licensed nurse staffing levels in the VA should enable effective supervision and management, but observation-based measures of care quality are necessary for accurate information about daily feeding assistance care provision.

  2. Apparatus and system for multivariate spectral analysis

    DOEpatents

    Keenan, Michael R.; Kotula, Paul G.

    2003-06-24

    An apparatus and system for determining the properties of a sample from measured spectral data collected from the sample by performing a method of multivariate spectral analysis. The method can include: generating a two-dimensional matrix A containing measured spectral data; providing a weighted spectral data matrix D by performing a weighting operation on matrix A; factoring D into the product of two matrices, C and S.sup.T, by performing a constrained alternating least-squares analysis of D=CS.sup.T, where C is a concentration intensity matrix and S is a spectral shapes matrix; unweighting C and S by applying the inverse of the weighting used previously; and determining the properties of the sample by inspecting C and S. This method can be used by a spectrum analyzer to process X-ray spectral data generated by a spectral analysis system that can include a Scanning Electron Microscope (SEM) with an Energy Dispersive Detector and Pulse Height Analyzer.

  3. PAH Baselines for Amazonic Surficial Sediments: A Case of Study in Guajará Bay and Guamá River (Northern Brazil).

    PubMed

    Rodrigues, Camila Carneiro Dos Santos; Santos, Ewerton; Ramos, Brunalisa Silva; Damasceno, Flaviana Cardoso; Correa, José Augusto Martins

    2018-06-01

    The 16 priority PAH were determined in sediment samples from the insular zone of Guajará Bay and Guamá River (Southern Amazon River mouth). Low hydrocarbon levels were observed and naphthalene was the most representative PAH. The low molecular weight PAH represented 51% of the total PAH. Statistical analysis showed that the sampling sites are not significantly different. Source analysis by PAH ratios and principal component analysis revealed that PAH are primary from a few rate of fossil fuel combustion, mainly related to the local small community activity. All samples presented no biological stress or damage potencial according to the sediment quality guidelines. This study discuss baselines for PAH in surface sediments from Amazonic aquatic systems based on source determination by PAH ratios and principal component analysis, sediment quality guidelines and through comparison with previous studies data.

  4. Optimization of the tungsten oxide technique for measurement of atmospheric ammonia

    NASA Technical Reports Server (NTRS)

    Brown, Kenneth G.

    1987-01-01

    Hollow tubes coated with tungstic acid have been shown to be of value in the determination of ammonia and nitric acid in ambient air. Practical application of this technique was demonstrated utilizing an automated sampling system for in-flight collection and analysis of atmospheric samples. Due to time constraints these previous measurements were performed on tubes that had not been well characterized in the laboratory. As a result the experimental precision could not be accurately estimated. Since the technique was being compared to other techniques for measuring these compounds, it became necessary to perform laboratory tests which would establish the reliability of the technique. This report is a summary of these laboratory experiments as they are applied to the determination of ambient ammonia concentration.

  5. The influence of variations in eating disorder-related symptoms on processing of emotional faces in a non-clinical female sample: An eye-tracking study.

    PubMed

    Sharpe, Emma; Wallis, Deborah J; Ridout, Nathan

    2016-06-30

    This study aimed to: (i) determine if the attention bias towards angry faces reported in eating disorders generalises to a non-clinical sample varying in eating disorder-related symptoms; (ii) examine if the bias occurs during initial orientation or later strategic processing; and (iii) confirm previous findings of impaired facial emotion recognition in non-clinical disordered eating. Fifty-two females viewed a series of face-pairs (happy or angry paired with neutral) whilst their attentional deployment was continuously monitored using an eye-tracker. They subsequently identified the emotion portrayed in a separate series of faces. The highest (n=18) and lowest scorers (n=17) on the Eating Disorders Inventory (EDI) were compared on the attention and facial emotion recognition tasks. Those with relatively high scores exhibited impaired facial emotion recognition, confirming previous findings in similar non-clinical samples. They also displayed biased attention away from emotional faces during later strategic processing, which is consistent with previously observed impairments in clinical samples. These differences were related to drive-for-thinness. Although we found no evidence of a bias towards angry faces, it is plausible that the observed impairments in emotion recognition and avoidance of emotional faces could disrupt social functioning and act as a risk factor for the development of eating disorders. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Laser based water equilibration method for d18O determination of water samples

    NASA Astrophysics Data System (ADS)

    Mandic, Magda; Smajgl, Danijela; Stoebener, Nils

    2017-04-01

    Determination of d18O with water equilibration method using mass spectrometers equipped with equilibration unit or Gas Bench is known already for many years. Now, with development of laser spectrometers this extends methods and possibilities to apply different technologies in laboratory but also in the field. The Thermo Scientific™ Delta Ray™ Isotope Ratio Infrared Spectrometer (IRIS) analyzer with the Universal Reference Interface (URI) Connect and Teledyne Cetac ASX-7100 offers high precision and throughput of samples. It employs optical spectroscopy for continuous measurement of isotope ratio values and concentration of carbon dioxide in ambient air, and also for analysis of discrete samples from vials, syringes, bags, or other user-provided sample containers. Test measurements and conformation of precision and accuracy of method determination d18O in water samples were done in Thermo Fisher application laboratory with three lab standards, namely ANST, Ocean II and HBW. All laboratory standards were previously calibrated with international reference material VSMOW2 and SLAP2 to assure accuracy of the isotopic values of the water. With method that we present in this work achieved repeatability and accuracy are 0.16‰ and 0.71‰, respectively, which fulfill requirements of regulatory method for wine and must after equilibration with CO2.

  7. Branching fraction measurement of J /ψ →KSKL and search for J /ψ →KSKS

    NASA Astrophysics Data System (ADS)

    Ablikim, M.; Achasov, M. N.; Ahmed, S.; Albrecht, M.; Alekseev, M.; Amoroso, A.; An, F. F.; An, Q.; Bai, J. Z.; Bai, Y.; Bakina, O.; Baldini Ferroli, R.; Ban, Y.; Bennett, D. W.; Bennett, J. V.; Berger, N.; Bertani, M.; Bettoni, D.; Bian, J. M.; Bianchi, F.; Boger, E.; Boyko, I.; Briere, R. A.; Cai, H.; Cai, X.; Cakir, O.; Calcaterra, A.; Cao, G. F.; Cetin, S. A.; Chai, J.; Chang, J. F.; Chelkov, G.; Chen, G.; Chen, H. S.; Chen, J. C.; Chen, M. L.; Chen, S. J.; Chen, X. R.; Chen, Y. B.; Chen, Z. X.; Chu, X. K.; Cibinetto, G.; Dai, H. L.; Dai, J. P.; Dbeyssi, A.; Dedovich, D.; Deng, Z. Y.; Denig, A.; Denysenko, I.; Destefanis, M.; de Mori, F.; Ding, Y.; Dong, C.; Dong, J.; Dong, L. Y.; Dong, M. Y.; Dorjkhaidav, O.; Dou, Z. L.; Du, S. X.; Duan, P. F.; Fang, J.; Fang, S. S.; Fang, X.; Fang, Y.; Farinelli, R.; Fava, L.; Fegan, S.; Feldbauer, F.; Felici, G.; Feng, C. Q.; Fioravanti, E.; Fritsch, M.; Fu, C. D.; Gao, Q.; Gao, X. L.; Gao, Y.; Gao, Y. G.; Gao, Z.; Garillon, B.; Garzia, I.; Goetzen, K.; Gong, L.; Gong, W. X.; Gradl, W.; Greco, M.; Gu, M. H.; Gu, S.; Gu, Y. T.; Guo, A. Q.; Guo, L. B.; Guo, R. P.; Guo, Y. P.; Haddadi, Z.; Han, S.; Hao, X. Q.; Harris, F. A.; He, K. L.; He, X. Q.; Heinsius, F. H.; Held, T.; Heng, Y. K.; Holtmann, T.; Hou, Z. L.; Hu, C.; Hu, H. M.; Hu, J. F.; Hu, T.; Hu, Y.; Huang, G. S.; Huang, J. S.; Huang, S. H.; Huang, X. T.; Huang, X. Z.; Huang, Z. L.; Hussain, T.; Ikegami Andersson, W.; Ji, Q.; Ji, Q. P.; Ji, X. B.; Ji, X. L.; Jiang, X. S.; Jiang, X. Y.; Jiao, J. B.; Jiao, Z.; Jin, D. P.; Jin, S.; Jin, Y.; Johansson, T.; Julin, A.; Kalantar-Nayestanaki, N.; Kang, X. L.; Kang, X. S.; Kavatsyuk, M.; Ke, B. C.; Khan, T.; Khoukaz, A.; Kiese, P.; Kliemt, R.; Koch, L.; Kolcu, O. B.; Kopf, B.; Kornicer, M.; Kuemmel, M.; Kuhlmann, M.; Kupsc, A.; Kühn, W.; Lange, J. S.; Lara, M.; Larin, P.; Lavezzi, L.; Leithoff, H.; Leng, C.; Li, C.; Li, Cheng; Li, D. M.; Li, F.; Li, F. Y.; Li, G.; Li, H. B.; Li, H. J.; Li, J. C.; Li, Jin; Li, K.; Li, K.; Li, K. J.; Li, Lei; Li, P. L.; Li, P. R.; Li, Q. Y.; Li, T.; Li, W. D.; Li, W. G.; Li, X. L.; Li, X. N.; Li, X. Q.; Li, Z. B.; Liang, H.; Liang, Y. F.; Liang, Y. T.; Liao, G. R.; Lin, D. X.; Liu, B.; Liu, B. J.; Liu, C. X.; Liu, D.; Liu, F. H.; Liu, Fang; Liu, Feng; Liu, H. B.; Liu, H. H.; Liu, H. H.; Liu, H. M.; Liu, J. B.; Liu, J. Y.; Liu, K.; Liu, K. Y.; Liu, Ke; Liu, L. D.; Liu, P. L.; Liu, Q.; Liu, S. B.; Liu, X.; Liu, Y. B.; Liu, Z. A.; Liu, Zhiqing; Long, Y. F.; Lou, X. C.; Lu, H. J.; Lu, J. G.; Lu, Y.; Lu, Y. P.; Luo, C. L.; Luo, M. X.; Luo, X. L.; Lyu, X. R.; Ma, F. C.; Ma, H. L.; Ma, L. L.; Ma, M. M.; Ma, Q. M.; Ma, T.; Ma, X. N.; Ma, X. Y.; Ma, Y. M.; Maas, F. E.; Maggiora, M.; Malik, Q. A.; Mao, Y. J.; Mao, Z. P.; Marcello, S.; Meng, Z. X.; Messchendorp, J. G.; Mezzadri, G.; Min, J.; Min, T. J.; Mitchell, R. E.; Mo, X. H.; Mo, Y. J.; Morales Morales, C.; Morello, G.; Muchnoi, N. Yu.; Muramatsu, H.; Mustafa, A.; Nefedov, Y.; Nerling, F.; Nikolaev, I. B.; Ning, Z.; Nisar, S.; Niu, S. L.; Niu, X. Y.; Olsen, S. L.; Ouyang, Q.; Pacetti, S.; Pan, Y.; Papenbrock, M.; Patteri, P.; Pelizaeus, M.; Pellegrino, J.; Peng, H. P.; Peters, K.; Pettersson, J.; Ping, J. L.; Ping, R. G.; Pitka, A.; Poling, R.; Prasad, V.; Qi, H. R.; Qi, M.; Qi, T. Y.; Qian, S.; Qiao, C. F.; Qin, N.; Qin, X. S.; Qin, Z. H.; Qiu, J. F.; Rashid, K. H.; Redmer, C. F.; Richter, M.; Ripka, M.; Rolo, M.; Rong, G.; Rosner, Ch.; Sarantsev, A.; Savrié, M.; Schnier, C.; Schoenning, K.; Shan, W.; Shao, M.; Shen, C. P.; Shen, P. X.; Shen, X. Y.; Sheng, H. Y.; Song, J. J.; Song, W. M.; Song, X. Y.; Sosio, S.; Sowa, C.; Spataro, S.; Sun, G. X.; Sun, J. F.; Sun, L.; Sun, S. S.; Sun, X. H.; Sun, Y. J.; Sun, Y. K.; Sun, Y. Z.; Sun, Z. J.; Sun, Z. T.; Tang, C. J.; Tang, G. Y.; Tang, X.; Tapan, I.; Tiemens, M.; Tsednee, B. T.; Uman, I.; Varner, G. S.; Wang, B.; Wang, B. L.; Wang, B. Q.; Wang, D.; Wang, D. Y.; Wang, Dan; Wang, K.; Wang, L. L.; Wang, L. S.; Wang, M.; Wang, P.; Wang, P. L.; Wang, W. P.; Wang, X. F.; Wang, Y.; Wang, Y. D.; Wang, Y. F.; Wang, Y. Q.; Wang, Z.; Wang, Z. G.; Wang, Z. H.; Wang, Z. Y.; Wang, Zongyuan; Weber, T.; Wei, D. H.; Wei, J. H.; Weidenkaff, P.; Wen, S. P.; Wiedner, U.; Wolke, M.; Wu, L. H.; Wu, L. J.; Wu, Z.; Xia, L.; Xia, Y.; Xiao, D.; Xiao, H.; Xiao, Y. J.; Xiao, Z. J.; Xie, X. H.; Xie, Y. G.; Xie, Y. H.; Xiong, X. A.; Xiu, Q. L.; Xu, G. F.; Xu, J. J.; Xu, L.; Xu, Q. J.; Xu, Q. N.; Xu, X. P.; Yan, L.; Yan, W. B.; Yan, W. C.; Yan, Y. H.; Yang, H. J.; Yang, H. X.; Yang, L.; Yang, Y. H.; Yang, Y. X.; Ye, M.; Ye, M. H.; Yin, J. H.; You, Z. Y.; Yu, B. X.; Yu, C. X.; Yu, J. S.; Yuan, C. Z.; Yuan, Y.; Yuncu, A.; Zafar, A. A.; Zeng, Y.; Zeng, Z.; Zhang, B. X.; Zhang, B. Y.; Zhang, C. C.; Zhang, D. H.; Zhang, H. H.; Zhang, H. Y.; Zhang, J.; Zhang, J. L.; Zhang, J. Q.; Zhang, J. W.; Zhang, J. Y.; Zhang, J. Z.; Zhang, K.; Zhang, L.; Zhang, S. Q.; Zhang, X. Y.; Zhang, Y.; Zhang, Y.; Zhang, Y. H.; Zhang, Y. T.; Zhang, Yu; Zhang, Z. H.; Zhang, Z. P.; Zhang, Z. Y.; Zhao, G.; Zhao, J. W.; Zhao, J. Y.; Zhao, J. Z.; Zhao, Lei; Zhao, Ling; Zhao, M. G.; Zhao, Q.; Zhao, S. J.; Zhao, T. C.; Zhao, Y. B.; Zhao, Z. G.; Zhemchugov, A.; Zheng, B.; Zheng, J. P.; Zheng, W. J.; Zheng, Y. H.; Zhong, B.; Zhou, L.; Zhou, X.; Zhou, X. K.; Zhou, X. R.; Zhou, X. Y.; Zhu, J.; Zhu, K.; Zhu, K. J.; Zhu, S.; Zhu, S. H.; Zhu, X. L.; Zhu, Y. C.; Zhu, Y. S.; Zhu, Z. A.; Zhuang, J.; Zou, B. S.; Zou, J. H.; Besiii Collaboration

    2017-12-01

    Using a sample of 1.31 ×109 J /ψ events collected with the BESIII detector at the BEPCII collider, we study the decays of J /ψ →KSKL and KSKS . The branching fraction of J /ψ →KSKL is determined to be B (J /ψ →KSKL)=(1.93 ±0.01 (stat )±0.05 (syst ))×10-4 , which significantly improves on previous measurements. No clear signal is observed for the J /ψ →KSKS process, and the upper limit at the 95% confidence level for its branching fraction is determined to be B (J /ψ →KSKS)<1.4 ×10-8 , which improves on the previous searches by 2 orders in magnitude and reaches the order of the Einstein-Podolsky-Rosen expectation.

  8. Determination of the molecular weight of poly(ethylene glycol) in biological samples by reversed-phase LC-MS with in-source fragmentation.

    PubMed

    Warrack, Bethanne M; Redding, Brian P; Chen, Guodong; Bolgar, Mark S

    2013-05-01

    PEGylation has been widely used to improve the biopharmaceutical properties of therapeutic proteins and peptides. Previous studies have used multiple analytical techniques to determine the fate of both the therapeutic molecule and unconjugated poly(ethylene glycol) (PEG) after drug administration. A straightforward strategy utilizing liquid chromatography-mass spectrometry (LC-MS) to characterize high-molecular weight PEG in biologic matrices without a need for complex sample preparation is presented. The method is capable of determining whether high-MW PEG is cleaved in vivo to lower-molecular weight PEG species. Reversed-phase chromatographic separation is used to take advantage of the retention principles of polymeric materials whereby elution order correlates with PEG molecular weight. In-source collision-induced dissociation (CID) combined with selected reaction monitoring (SRM) or selected ion monitoring (SIM) mass spectrometry (MS) is then used to monitor characteristic PEG fragment ions in biological samples. MS provides high sensitivity and specificity for PEG and the observed retention times in reversed-phase LC enable estimation of molecular weight. This method was successfully used to characterize PEG molecular weight in mouse serum samples. No change in molecular weight was observed for 48 h after dosing.

  9. Application and optimization of microwave-assisted extraction and dispersive liquid-liquid microextraction followed by high-performance liquid chromatography for sensitive determination of polyamines in turkey breast meat samples.

    PubMed

    Bashiry, Moein; Mohammadi, Abdorreza; Hosseini, Hedayat; Kamankesh, Marzieh; Aeenehvand, Saeed; Mohammadi, Zaniar

    2016-01-01

    A novel method based on microwave-assisted extraction and dispersive liquid-liquid microextraction (MAE-DLLME) followed by high-performance liquid chromatography (HPLC) was developed for the determination of three polyamines from turkey breast meat samples. Response surface methodology (RSM) based on central composite design (CCD) was used to optimize the effective factors in DLLME process. The optimum microextraction efficiency was obtained under optimized conditions. The calibration graphs of the proposed method were linear in the range of 20-200 ng g(-1), with the coefficient determination (R(2)) higher than 0.9914. The relative standard deviations were 6.72-7.30% (n = 7). The limits of detection were in the range of 0.8-1.4 ng g(-1). The recoveries of these compounds in spiked turkey breast meat samples were from 95% to 105%. The increased sensitivity in using the MAE-DLLME-HPLC-UV has been demonstrated. Compared with previous methods, the proposed method is an accurate, rapid and reliable sample-pretreatment method. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Is drug-resistant Mycobacterium leprae a real cause for concern?: First approach to molecular monitoring of multibacillary Colombian patients with and without previous leprosy treatment.

    PubMed

    Guerrero, Martha Inírida; Colorado, Claudia Lucía; Torres, José Fernando; León, Clara Inés

    2014-04-01

    There is no information in Colombia on Mycobacterium leprae primary and secondary drug resistance in regards to the WHO-multidrug therapy regime. On the other hand, public health authorities around the world have issued various recommendations, one of which prompts for the immediate organization of resistance surveillance through simple molecular methods. To determine the prevalence of Mycobacterium leprae drug resistance to rifampicin, ofloxacin and dapsone in untreated and previously treated patients at the Centro Dermatológico Federico Lleras Acosta during the 1985-2004 period. We conducted a retrospective study which included multibacillary patient biopsies through elective sampling: 381 of them from new patients and 560 from previously treated patients. Using a microtome, we obtained six slides from each skin biopsy preserved in paraffin, and we extracted M. leprae DNA. We amplified three molecular targets through PCR and obtained the patterns of drug resistance to dapsone, rifampicin and ofloxacin by reverse hybridization. Finally, we collected epidemiological, clinical and demographical data for analyses. From 941 samples under study, 4.14% of them were resistant to one or more drugs, and 5.77 and 3.04% had resistant genotypes in new and previously treated patients, respectively. Total resistance for each drug was 0.43% for dapsone, 3.19% for rifampicin and 1.17% for ofloxacin. We found statistically significant differences for rifampicin and for the total population when comparing the results from untreated versus previously treated patients. Two thirds of the resistant samples were resistant to rifampicin alone or combined. The standard multidrug therapy schemes continue being effective for leprosy cases; however, it is necessary to guarantee adherence and regularity. Surveillance to drug resistance in new and previously treated leprosy cases should be established.

  11. A voxel-based approach to gray matter asymmetries.

    PubMed

    Luders, E; Gaser, C; Jancke, L; Schlaug, G

    2004-06-01

    Voxel-based morphometry (VBM) was used to analyze gray matter (GM) asymmetries in a large sample (n = 60) of male and female professional musicians with and without absolute pitch (AP). We chose to examine these particular groups because previous studies using traditional region-of-interest (ROI) analyses have shown differences in hemispheric asymmetry related to AP and gender. Voxel-based methods may have advantages over traditional ROI-based methods since the analysis can be performed across the whole brain with minimal user bias. After determining that the VBM method was sufficiently sensitive for the detection of differences in GM asymmetries between groups, we found that male AP musicians were more leftward lateralized in the anterior region of the planum temporale (PT) than male non-AP musicians. This confirmed the results of previous studies using ROI-based methods that showed an association between PT asymmetry and the AP phenotype. We further observed that male non-AP musicians revealed an increased leftward GM asymmetry in the postcentral gyrus compared to female non-AP musicians, again corroborating results of a previously published study using ROI-based methods. By analyzing hemispheric GM differences across our entire sample, we were able to partially confirm findings of previous studies using traditional morphometric techniques, as well as more recent, voxel-based analyses. In addition, we found some unusually pronounced GM asymmetries in our musician sample not previously detected in subjects unselected for musical training. Since we were able to validate gender- and AP-related brain asymmetries previously described using traditional ROI-based morphometric techniques, the results of our analyses support the use of VBM for examinations of GM asymmetries.

  12. Determination of 129I in environmental samples by AMS and NAA using an anion exchange resin disk

    NASA Astrophysics Data System (ADS)

    Suzuki, Takashi; Banba, Shigeru; Kitamura, Toshikatsu; Kabuto, Shoji; Isogai, Keisuke; Amano, Hikaru

    2007-06-01

    We have developed a new extraction method for the measurement of 129I by accelerator mass spectrometry (AMS) utilizing an anion exchange resin disk. In comparison to traditional methods such as solvent extraction and ion exchange, this method provides for simple and quick sample handling. This extraction method was tested on soil, seaweed and milk samples, but because of disk clogging, the milk samples and some of the seaweed could not be applied successfully. Using this new extraction method to prepare samples for AMS analysis produced isotope ratios of iodine in good agreement with neutron activation analysis (NAA). The disk extraction method which take half an hour is faster than previous techniques, such as solvent extraction or ion exchange which take a few hours. The combination of the disk method and the AMS measurement is a powerful tool for the determination of 129I. Furthermore, these data will be available for the environmental monitoring before and during the operation of a new nuclear fuel reprocessing plant in Japan.

  13. Determination of fat and total protein content in milk using conventional digital imaging.

    PubMed

    Kucheryavskiy, Sergey; Melenteva, Anastasiia; Bogomolov, Andrey

    2014-04-01

    The applicability of conventional digital imaging to quantitative determination of fat and total protein in cow's milk, based on the phenomenon of light scatter, has been proved. A new algorithm for extracting features from digital images of milk samples has been developed. The algorithm takes into account spatial distribution of light, diffusely transmitted through a sample. The proposed method has been tested on two sample sets prepared from industrial raw milk standards, with variable fat and protein content. Partial Least-Squares (PLS) regression on the features calculated from images of monochromatically illuminated milk samples resulted in models with high prediction performance when analysed the sets separately (best models with cross-validated R(2)=0.974 for protein and R(2)=0.973 for fat content). However when analysed the sets jointly with the obtained results were significantly worse (best models with cross-validated R(2)=0.890 for fat content and R(2)=0.720 for protein content). The results have been compared with previously published Vis/SW-NIR spectroscopic study of similar samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Abnormal cerebrospinal fluid protein indices in schizophrenia.

    PubMed

    Kirch, D G; Kaufmann, C A; Papadopoulos, N M; Martin, B; Weinberger, D R

    1985-10-01

    Determinations of albumin and immunoglobulin G (IgG) were performed in paired cerebrospinal fluid (CSF) and serum samples from 24 subjects with schizophrenia. These determinations allowed calculation of two indices, one that is an indicator of integrity of the blood-brain barrier and the other a measure of selective IgG production within the central nervous system (CNS). In comparison with previously determined reference values, 7 of 24 (29%) subjects showed increased blood-brain barrier permeability, and 8 of 24 (33%) demonstrated elevated endogenous CNS IgG production. One of these eight also demonstrated oligoclonal banding on high-resolution protein electrophoresis of the CSF.

  15. A noninvasive, direct real-time PCR method for sex determination in multiple avian species

    USGS Publications Warehouse

    Brubaker, Jessica L.; Karouna-Renier, Natalie K.; Chen, Yu; Jenko, Kathryn; Sprague, Daniel T.; Henry, Paula F.P.

    2011-01-01

    Polymerase chain reaction (PCR)-based methods to determine the sex of birds are well established and have seen few modifications since they were first introduced in the 1990s. Although these methods allowed for sex determination in species that were previously difficult to analyse, they were not conducive to high-throughput analysis because of the laboriousness of DNA extraction and gel electrophoresis. We developed a high-throughput real-time PCR-based method for analysis of sex in birds, which uses noninvasive sample collection and avoids DNA extraction and gel electrophoresis.

  16. Monitoring aroma changes during human milk storage at +4 °C by sensory and quantification experiments.

    PubMed

    Spitzer, Johanna; Klos, Katharina; Buettner, Andrea

    2013-12-01

    The effect of human milk storage in the refrigerator has been investigated with regard to sensory changes and modifications to the molecular composition of the milk odour-active volatiles. In the present study, characteristic odorants from fat oxidation, known from previous studies, as well as free fatty acids were quantified as representative marker substances by means of stable isotope dilution assays of fresh milk samples and milk samples stored at +4 °C for one and three days, respectively. Sensory evaluation showed that rancid and sweaty odour attributes were generated during storage, resulting in an unpleasant aroma profile for adults; however, odour changes were not as pronounced as those observed in our previous study for freeze storage. Fatty and buttery odour notes and a cooked milk-like smell were also generated. In total eight odorants from fat oxidation were determined and some potent odorants showed slight concentration increases. Moreover, five free fatty acids were determined and these all showed drastic concentration increases, even after storage for just one day. These investigations support our previous findings that storage recommendations for breast milk might need to be slightly reconsidered in view of potential sensory changes; on the other hand, no negative physiological effects are to be expected from these changes. Copyright © 2013 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  17. Mycobacterium tuberculosis resistance to antituberculosis drugs in Mozambique*, **

    PubMed Central

    Pires, Germano Manuel; Folgosa, Elena; Nquobile, Ndlovu; Gitta, Sheba; Cadir, Nureisha

    2014-01-01

    OBJECTIVE: To determine the drug resistance profile of Mycobacterium tuberculosis in Mozambique. METHODS: We analyzed secondary data from the National Tuberculosis Referral Laboratory, in the city of Maputo, Mozambique, and from the Beira Regional Tuberculosis Referral Laboratory, in the city of Beira, Mozambique. The data were based on culture-positive samples submitted to first-line drug susceptibility testing (DST) between January and December of 2011. We attempted to determine whether the frequency of DST positivity was associated with patient type or provenance. RESULTS: During the study period, 641 strains were isolated in culture and submitted to DST. We found that 374 (58.3%) were resistant to at least one antituberculosis drug and 280 (43.7%) were resistant to multiple antituberculosis drugs. Of the 280 multidrug-resistant tuberculosis cases, 184 (65.7%) were in previously treated patients, most of whom were from southern Mozambique. Two (0.71%) of the cases of multidrug-resistant tuberculosis were confirmed to be cases of extensively drug-resistant tuberculosis. Multidrug-resistant tuberculosis was most common in males, particularly those in the 21-40 year age bracket. CONCLUSIONS: M. tuberculosis resistance to antituberculosis drugs is high in Mozambique, especially in previously treated patients. The frequency of M. tuberculosis strains that were resistant to isoniazid, rifampin, and streptomycin in combination was found to be high, particularly in samples from previously treated patients. PMID:24831398

  18. BLIND ordering of large-scale transcriptomic developmental timecourses.

    PubMed

    Anavy, Leon; Levin, Michal; Khair, Sally; Nakanishi, Nagayasu; Fernandez-Valverde, Selene L; Degnan, Bernard M; Yanai, Itai

    2014-03-01

    RNA-Seq enables the efficient transcriptome sequencing of many samples from small amounts of material, but the analysis of these data remains challenging. In particular, in developmental studies, RNA-Seq is challenged by the morphological staging of samples, such as embryos, since these often lack clear markers at any particular stage. In such cases, the automatic identification of the stage of a sample would enable previously infeasible experimental designs. Here we present the 'basic linear index determination of transcriptomes' (BLIND) method for ordering samples comprising different developmental stages. The method is an implementation of a traveling salesman algorithm to order the transcriptomes according to their inter-relationships as defined by principal components analysis. To establish the direction of the ordered samples, we show that an appropriate indicator is the entropy of transcriptomic gene expression levels, which increases over developmental time. Using BLIND, we correctly recover the annotated order of previously published embryonic transcriptomic timecourses for frog, mosquito, fly and zebrafish. We further demonstrate the efficacy of BLIND by collecting 59 embryos of the sponge Amphimedon queenslandica and ordering their transcriptomes according to developmental stage. BLIND is thus useful in establishing the temporal order of samples within large datasets and is of particular relevance to the study of organisms with asynchronous development and when morphological staging is difficult.

  19. Huminite reflectance measurements of Paleocene and Upper Cretaceous coals from borehole cuttings, Zavala and Dimmit counties, South Texas

    USGS Publications Warehouse

    Hackley, Paul C.; Hook, Robert W.; Warwick, Peter D.

    2005-01-01

    The reflectance of huminite in 19 cuttings samples was determined in support of ongoing investigations into the coal bed methane potential of subsurface Paleocene and Upper Cretaceous coals of South Texas. Coal cuttings were obtained from the Core Research Center of the Bureau of Economic Geology, The University of Texas at Austin. Geophysical logs, mud-gas logs, driller's logs, completion cards, and scout tickets were used to select potentially coal-bearing sample suites and to identify specific sample depths. Reflectance measurements indicate coals of subbituminous rank are present in a wider area in South Texas than previously recognized.

  20. Getting a Job. A Study of Contacts and Careers. Second Edition.

    ERIC Educational Resources Information Center

    Granovetter, Mark

    A study was conducted in 1974 to determine how professional, technical, and managerial males obtain the information that leads to getting a job. Data were gathered by selecting a random sample of 457 men in Newton, Massachusetts, who had changed jobs within the previous 5 years. Personal interviews were conducted with 100 men and 182 mailed…

  1. FT-mid-IR spectroscopic investigation of fiber maturity and crystallinity at single boll level and a comparison with XRD approach

    USDA-ARS?s Scientific Manuscript database

    In previous study, we have reported the development of simple algorithms for determining fiber maturity and crystallinity from Fourier transform (FT) -mid-infrared (IR) measurement. Due to its micro-sampling feature, we were able to assess the fiber maturity and crystallinity at different portions o...

  2. Is Mom Still Doing It All?: Reexamining Depictions of Family Work in Popular Advertising

    ERIC Educational Resources Information Center

    Robinson, Bryan K.; Hunter, Erica

    2008-01-01

    This study examines a sample of 299 advertisements from 4 of the top 10 circulated magazines of 2005 to see how contemporary advertising depicts household labor. Modeling after previous studies that examined the depiction of gender in family advertising, this study seeks to determine whether advertising reflects the changes in families that have…

  3. The Role of Maternal Depression in Accessing Early Intervention Services for Children with Developmental Delay

    ERIC Educational Resources Information Center

    Colgan, Siobhan Eileen

    2012-01-01

    This study investigated the relationship between maternal depression and children's access to early intervention services among a sample of children with developmental delay at age two who were determined to be eligible for early intervention services, were full term and of normal birth weight, and were not previously identified with any special…

  4. A reassessment of the compressive strength properties of southern yellow pine bark

    Treesearch

    Thomas L. Eberhardt

    2007-01-01

    Samples of southern yellow pine outer bark and wood were tested in compression to determine values for modulus of elasticity, stress at proportional limit, and maximum crushing strength. Results reported here resolve inconsistencies in the compressive strength data previously reported by others for pine bark. Testing of solvent-treated bark blocks suggests that...

  5. Teachers' Perceptions of Employment-Related Problems: A Survey of Teachers in Two States.

    ERIC Educational Resources Information Center

    Cutrer, Susan S.; Daniel, Larry G.

    This study was conducted to determine the degree to which a randomly selected sample of teachers in Mississippi and Louisiana (N=291) experience various types of work-related problems. It provides an opportunity to either confirm or deny the findings of previous studies, many of them limited by various methodological problems. Data were collected…

  6. Estimate of colostral immunoglobulin G concentration using refractometry without or with caprylic acid fractionation.

    PubMed

    Morrill, K M; Conrad, E; Polo, J; Lago, A; Campbell, J; Quigley, J; Tyler, H

    2012-07-01

    Our objectives were to evaluate the use of refractometry as a means of estimating immunoglobulin G (IgG) concentration of bovine maternal colostrum (MC) and determine if fractionation of MC using caprylic acid (CA) improved estimates of IgG. Samples (n=85) of MC were collected from a single dairy in California and used to determine the method of CA fraction that produced the best prediction of IgG based on CA fractionation followed by refractometry. Subsequently, samples of MC (n=827) were collected from 67 farms in 12 states to compare refractometry with or without CA fractionation as methods to estimate IgG concentration. Samples were collected from the feeding pool and consisted of fresh (n=196), previously frozen (n=479), or refrigerated (n=152) MC. Samples were further classified by the number freeze-thaw cycles before analysis. Fractionation with CA was conducted by adding 1 mL of MC to a tube containing 75 μL of CA and 1 mL of 0.06 M acetic acid. The tube was shaken and allowed to react for 1 min. Refractive index of the IgG-rich supernatant (nDf) was determined using a digital refractometer. Whole, nonfractionated MC was analyzed for IgG by radial immunodiffusion (RID) and refractive index (nDw). The relationship between nDf and IgG (r=0.53; n=805) was weak, whereas that between nDw and IgG was stronger (r=0.73; n=823). Fresh samples analyzed by refractometry that subsequently went through 1 freeze-thaw cycle before RID analysis resulted in the strongest relationship between IgG and nDf or nDw (r=0.93 and 0.90, respectively). The MC samples collected fresh on the farm but frozen 2 or more times before analysis by refractometry or RID had low correlations between IgG and nDf and nDw (r=0.09 and 0.01). Samples refrigerated or frozen on the farm before analysis had weaker relationships between RID and nDf or nDw (r=0.38 to 0.80), regardless of the number of freeze-thaw cycles. Breed and lactation number did not affect the accuracy of either test. These results indicated that refractometry, without or with CA fractionation, was an accurate and rapid method to determine IgG concentration when samples of MC were not previously stored before refractometry and frozen only once before RID analysis. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  7. Antioxidant capacity, phenolic acids and caffeine contents of some commercial coffees available on the Romanian market.

    PubMed

    Trandafir, Ion; Nour, Violeta; Ionica, Mira Elena

    2013-03-01

    In the present study a simple and highly sensitive RP-HPLC method has been established for simultaneous determination of chlorogenic acid, caffeic acid, vanillic acid and caffeine in coffee samples. The method has been applied to eight different coffees available on the Romanian market which were previously analysed concerning the total polyphenols content and antioxidant capacity. Reduction of the DPPH radical was used to determine the antioxidant capacity of the coffee extracts while the total polyphenols content was determined by spectrophotometry (Folin Ciocalteu's method). The total polyphenols content ranged from 1.98 g GAE/100 g to 4.19 g GAE/100 g while the caffeine content ranged from 1.89 g/100 g to 3.05 g/100 g. A large variability was observed in chlorogenic acid content of the investigated coffee samples which ranged between 0.6 and 2.32 g/100 g.

  8. Atomic emission spectrometer/spectrograph for the determination of barium in microamounts of diatom ash

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bankston, D.C.; Fisher, N.S.

    1977-06-01

    The development and routine application of a method for the determination of trace levels of barium in microsamples (5-10 mg) of diatom ash is described Acid-dissolved lithium metaborate fusion melts of ash samples are analyzed using a spectrometer/spectrograph equipped with a dc argon plasma jet excitation source and an echelle diffraction grating. Sample, standard, and blank solutions are buffered by lithium contributed by the flux, to a degree sufficient to reduce matrix effects to acceptable levels. Previous barium determinations by other analytical techniques, on seven interlaboratory reference materials, have been used to establish the accuracy of our results. The averagemore » relative standard deviation for the instrumental analyses was 0.07. Using recommended instrument settings, moreover, the lowest concentration of barium visible in synthetic standard solutions lies just below 2 ..mu..g/L, which is equivalent to 2 ..mu..g/g in the ash.« less

  9. Revised Toxicological Assessment of ISS Air Quality: May 2012 - August 2012

    NASA Technical Reports Server (NTRS)

    Meyers, Valerie

    2012-01-01

    A summary of the analytical results from 12 grab sample containers (GSCs) collected on ISS and returned aboard 30S is shown in Table 1. The average recoveries of the 3 surrogate standards from the GSCs were as follows: 12C-acetone, 115 +/-- 11%; fluorobenzene, 108 +/- 8%; and chlorobenzene, 102 +/- 16%. Shaded rows indicate data that re limited due to low sample pressures. For completeness, previously reported data from the US Lab collected in May 2012 are included here as well. The revised report provides results from one returned sample that was unlabeled and originally assumed to be unused. The sample was prepared and analyzed for the purpose of measuring the surrogate compounds. It was later determined, based on serial number, that this was the HTB3 first ingress sample.

  10. New tool for getting data on the field for paleoclimate and paleoceanography data based on isotope 13C and 18O measurements

    NASA Astrophysics Data System (ADS)

    Mandic, M.; Stöbener, N.; Smajgl, D.

    2017-12-01

    For many decades different instrumental methods involving generations of the isotope ratio mass spectrometers with different periphery units for sample preparation, have provided scientifically required high precision, and high throughput of samples for varies application - from geological and hydrological to food and forensic. With this work we introduce automated measurement of δ13C and δ18O from solid carbonate samples, DIC and δ18O of water. We have demonstrated usage of a Thermo Scientific™ Delta Ray™ IRIS with URI Connect on certified reference materials and confirmed the high achievable accuracy and a precision better then <0.1‰ for both δ13C and δ18O, in the laboratory or the field with same precision and throughput of samples. With equilibration method for determination of δ18O in water samples, which we present in this work, achieved repeatability and accuracy are 0.12‰ and 0.68‰ respectively, which fulfill requirements of regulatory methods. The preparation of the samples for carbonate and DIC analysis on the Delta Ray IRIS with URI Connect is similar to the previously mentioned Gas Bench II methods. Samples are put into vials and phosphoric acid is added. The resulting sample-acid chemical reaction releases CO2 gas, which is then introduced into the Delta Ray IRIS via the Variable Volume. Three international standards of carbonate materials (NBS-18, NBS-19 and IAEA-CO-1) were analyzed. NBS-18 and NBS-19 were used as standards for calibration, and IAEA-CO-1 was treated as unknown. For water sample analysis equilibration method with 1% of CO2 in dry air was used. Test measurements and conformation of precision and accuracy of method determination δ18O in water samples were done with three lab standards, namely ANST, OCEAN 2 and HBW. All laboratory standards were previously calibrated with international reference material VSMOW2 and SLAP2 to assure accuracy of the isotopic values. The Principle of Identical Treatment was applied in sample and standard preparation, in measurement procedure, as well as in the evaluation of the results.

  11. Development and validation of micellar liquid chromatographic methods for the determination of antibiotics in different matrixes.

    PubMed

    Rambla-Alegre, Maria; Esteve-Romero, Josep; Carda-Broch, Samuel

    2011-01-01

    Antibiotics are the most important bioactive and chemotherapeutic compounds to be produced by microbiological synthesis, and they have proved their worth in a variety of fields, such as medicinal chemistry, agriculture, and the food industry. Interest in antibiotics has grown in parallel with an increasingly high degree of productivity in the field of analytical applications. Therefore, it is necessary to develop chromatographic procedures capable of determining various drugs simultaneously in the shortest possible time. Micellar liquid chromatography (MLC) is an RP-HPLC technique that offers advantages over conventional HPLC as far as sample preparation, selectivity, and versatility are concerned. Its main advantage is that samples can be injected directly into the chromatographic system with no previous preparation step. This paper mainly focuses on the results of the authors' own recent research and reports the chromatographic conditions for determination of various antibiotics (penicillins, quinolones, and sulfonamides) in different matrixes (pharmaceuticals, biological fluids, and food). The work of other authors on MLC-based antibiotic determination has been included.

  12. Simultaneous and rapid determination of multiple component concentrations in a Kraft liquor process stream

    DOEpatents

    Li, Jian [Marietta, GA; Chai, Xin Sheng [Atlanta, GA; Zhu, Junyoung [Marietta, GA

    2008-06-24

    The present invention is a rapid method of determining the concentration of the major components in a chemical stream. The present invention is also a simple, low cost, device of determining the in-situ concentration of the major components in a chemical stream. In particular, the present invention provides a useful method for simultaneously determining the concentrations of sodium hydroxide, sodium sulfide and sodium carbonate in aqueous kraft pulping liquors through use of an attenuated total reflectance (ATR) tunnel flow cell or optical probe capable of producing a ultraviolet absorbency spectrum over a wavelength of 190 to 300 nm. In addition, the present invention eliminates the need for manual sampling and dilution previously required to generate analyzable samples. The inventive method can be used in Kraft pulping operations to control white liquor causticizing efficiency, sulfate reduction efficiency in green liquor, oxidation efficiency for oxidized white liquor and the active and effective alkali charge to kraft pulping operations.

  13. Comparative investigation of Fourier transform infrared (FT-IR) spectroscopy and X-ray diffraction (XRD) in the determination of cotton fiber crystallinity.

    PubMed

    Liu, Yongliang; Thibodeaux, Devron; Gamble, Gary; Bauer, Philip; VanDerveer, Don

    2012-08-01

    Despite considerable efforts in developing curve-fitting protocols to evaluate the crystallinity index (CI) from X-ray diffraction (XRD) measurements, in its present state XRD can only provide a qualitative or semi-quantitative assessment of the amounts of crystalline or amorphous fraction in a sample. The greatest barrier to establishing quantitative XRD is the lack of appropriate cellulose standards, which are needed to calibrate the XRD measurements. In practice, samples with known CI are very difficult to prepare or determine. In a previous study, we reported the development of a simple algorithm for determining fiber crystallinity information from Fourier transform infrared (FT-IR) spectroscopy. Hence, in this study we not only compared the fiber crystallinity information between FT-IR and XRD measurements, by developing a simple XRD algorithm in place of a time-consuming and subjective curve-fitting process, but we also suggested a direct way of determining cotton cellulose CI by calibrating XRD with the use of CI(IR) as references.

  14. Integrated Structural Biology for α-Helical Membrane Protein Structure Determination.

    PubMed

    Xia, Yan; Fischer, Axel W; Teixeira, Pedro; Weiner, Brian; Meiler, Jens

    2018-04-03

    While great progress has been made, only 10% of the nearly 1,000 integral, α-helical, multi-span membrane protein families are represented by at least one experimentally determined structure in the PDB. Previously, we developed the algorithm BCL::MP-Fold, which samples the large conformational space of membrane proteins de novo by assembling predicted secondary structure elements guided by knowledge-based potentials. Here, we present a case study of rhodopsin fold determination by integrating sparse and/or low-resolution restraints from multiple experimental techniques including electron microscopy, electron paramagnetic resonance spectroscopy, and nuclear magnetic resonance spectroscopy. Simultaneous incorporation of orthogonal experimental restraints not only significantly improved the sampling accuracy but also allowed identification of the correct fold, which is demonstrated by a protein size-normalized transmembrane root-mean-square deviation as low as 1.2 Å. The protocol developed in this case study can be used for the determination of unknown membrane protein folds when limited experimental restraints are available. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. CPTAC researchers report first large-scale integrated proteomic and genomic analysis of a human cancer | Office of Cancer Clinical Proteomics Research

    Cancer.gov

    Investigators from the National Cancer Institute's Clinical Proteomic Tumor Analysis Consortium (CPTAC) who comprehensively analyzed 95 human colorectal tumor samples, have determined how gene alterations identified in previous analyses of the same samples are expressed at the protein level. The integration of proteomic and genomic data, or proteogenomics, provides a more comprehensive view of the biological features that drive cancer than genomic analysis alone and may help identify the most important targets for cancer detection and intervention.

  16. Liquid-liquid microextraction in a multicommuted flow system for direct spectrophotometric determination of iodine value in biodiesel.

    PubMed

    Pereira, Andréia C; Rocha, Fábio R P

    2014-06-04

    A flow-based procedure was developed for the direct spectrophotometric determination of the iodine value (IV) in biodiesel. The procedure was based on the microextraction/reaction of unsaturated compounds with triiodide ions in an aqueous medium by inserting the reagent solution between the aliquots of biodiesel without any pretreatment. The interaction occurred through the biodiesel film formed on the inner walls of the hydrophobic tube used as the reactor and at the aqueous/biodiesel interfaces. The spectrophotometric detection was based on the discoloration of the I3(-) reagent in the aqueous phase by using a glass tube coupled to a fiber-optic spectrophotometer as the detection cell. Reference solutions were prepared by dilution of biodiesel samples with previously determined IV in hexane. The analytical response was linear for IV from 13 to 135 g I2/100 g with a detection limit of 5 g I2/100 g. A coefficient of variation of 1.7% (n=10) and a sampling rate of 108 determinations per hour were achieved by consuming 224 μL of the sample and 200 μg of I2 per determination. The slopes of analytical curves obtained with three different biodiesel samples were in agreement (variations in slopes lower than 3.1%), thus indicating an absence of any matrix effects. Results for biodiesel samples from different sources agreed with the volumetric official procedure at the 95% confidence level. The proposed procedure is therefore a simple, fast, and reliable alternative for estimating the iodine value of biodiesel. Copyright © 2014. Published by Elsevier B.V.

  17. Determination of vitamins D2 and D3 in selected food matrices by online high-performance liquid chromatography-gas chromatography-mass spectrometry (HPLC-GC-MS).

    PubMed

    Nestola, Marco; Thellmann, Andrea

    2015-01-01

    An online normal-phase liquid chromatography-gas chromatography-mass spectrometry (HPLC-GC-MS) method was developed for the determination of vitamins D2 and D3 in selected food matrices. Transfer of the sample from HPLC to GC was realized by large volume on-column injection; detection was performed with a time-of-flight mass spectrometer (TOF-MS). Typical GC problems in the determination of vitamin D such as sample degradation or sensitivity issues, previously reported in the literature, were not observed. Determination of total vitamin D content was done by quantitation of its pyro isomer based on an isotopically labelled internal standard (ISTD). Extracted ion traces of analyte and ISTD showed cross-contribution, but non-linearity of the calibration curve was not determined inside the chosen calibration range by selection of appropriate quantifier ions. Absolute limits of detection (LOD) and quantitation (LOQ) for vitamins D2 and D3 were calculated as approximately 50 and 150 pg, respectively. Repeatability with internal standard correction was below 2 %. Good agreement between quantitative results of an established high-performance liquid chromatography with UV detection (HPLC-UV) method and HPLC-GC-MS was found. Sterol-enriched margarine was subjected to HPLC-GC-MS and HPLC-MS/MS for comparison, because HPLC-UV showed strong matrix interferences. HPLC-GC-MS produced comparable results with less manual sample cleanup. In summary, online hyphenation of HPLC and GC allowed a minimization in manual sample preparation with an increase of sample throughput.

  18. An enhanced rheometer inertia correction procedure (ERIC) for the study of gelling systems using combined motor-transducer rheometers

    NASA Astrophysics Data System (ADS)

    Hudson, R. E.; Holder, A. J.; Hawkins, K. M.; Williams, P. R.; Curtis, D. J.

    2017-12-01

    The rheological characterisation of viscoelastic materials undergoing a sol-gel transition at the Gel Point (GP) has important applications in a wide range of industrial, biological, and clinical environments and can provide information regarding both kinetic and microstructural aspects of gelation. The most rigorous basis for identifying the GP involves exploiting the frequency dependence of the real and imaginary parts of the complex shear modulus of the critical gel (the system at the GP) measured under small amplitude oscillatory shear conditions. This approach to GP identification requires that rheological data be obtained over a range of oscillatory shear frequencies. Such measurements are limited by sample mutation considerations (at low frequencies) and, when experiments are conducted using combined motor-transducer (CMT) rheometers, by instrument inertia considerations (at high frequencies). Together, sample mutation and inertia induced artefacts can lead to significant errors in the determination of the GP. Overcoming such artefacts is important, however, as the extension of the range of frequencies available to the experimentalist promises both more accurate GP determination and the ability to study rapidly gelling samples. Herein, we exploit the frequency independent viscoelastic properties of the critical gel to develop and evaluate an enhanced rheometer inertia correction procedure. The procedure allows acquisition of valid GP data at previously inaccessible frequencies (using CMT rheometers) and is applied in a study of the concentration dependence of bovine gelatin gelation GP parameters. A previously unreported concentration dependence of the stress relaxation exponent (α) for critical gelatin gels has been identified, which approaches a limiting value (α = 0.7) at low gelatin concentrations, this being in agreement with previous studies and theoretical predictions for percolating systems at the GP.

  19. Equations based on anthropometry to predict body fat measured by absorptiometry in schoolchildren and adolescents.

    PubMed

    Ortiz-Hernández, Luis; Vega López, A Valeria; Ramos-Ibáñez, Norma; Cázares Lara, L Joana; Medina Gómez, R Joab; Pérez-Salgado, Diana

    To develop and validate equations to estimate the percentage of body fat of children and adolescents from Mexico using anthropometric measurements. A cross-sectional study was carried out with 601 children and adolescents from Mexico aged 5-19 years. The participants were randomly divided into the following two groups: the development sample (n=398) and the validation sample (n=203). The validity of previously published equations (e.g., Slaughter) was also assessed. The percentage of body fat was estimated by dual-energy X-ray absorptiometry. The anthropometric measurements included height, sitting height, weight, waist and arm circumferences, skinfolds (triceps, biceps, subscapular, supra-iliac, and calf), and elbow and bitrochanteric breadth. Linear regression models were estimated with the percentage of body fat as the dependent variable and the anthropometric measurements as the independent variables. Equations were created based on combinations of six to nine anthropometric variables and had coefficients of determination (r 2 ) equal to or higher than 92.4% for boys and 85.8% for girls. In the validation sample, the developed equations had high r 2 values (≥85.6% in boys and ≥78.1% in girls) in all age groups, low standard errors (SE≤3.05% in boys and ≤3.52% in girls), and the intercepts were not different from the origin (p>0.050). Using the previously published equations, the coefficients of determination were lower, and/or the intercepts were different from the origin. The equations developed in this study can be used to assess the percentage of body fat of Mexican schoolchildren and adolescents, as they demonstrate greater validity and lower error compared with previously published equations. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  20. Use of the Keele injector for sample introduction for gas chromatographic analysis of vinclozolin in lettuces.

    PubMed

    Shim, J H; Lee, Y S; Kim, M R; Lee, C J; Kim, I S

    2003-10-10

    We examined a Keele injector for sample introduction for gas chromatographic analysis of vinclozolin treated in lettuces. Samples in milligram quantity were introduced into a glass tube in a Keele injector at a gas chromatograph injection port. The glass tube was then crushed to allow the sample to carry onto a capillary column in a normal manner. The standard calibration curve for quantitative detection of vinclozolin was obtained by determining vinclozolin spiked in samples at variable concentrations. The calibration curve showed a linear response to vinclozolin ranging from 0.05 to 1.0 microg/g, giving a slope value of 174.8, the y-intercept value of -2.8146 and the mean r2-value of 0.9994. Limit of quantification for vinclozolin was 0.05 microg/g by this method, comparable to 0.01 microg/g by a normal injector. When samples treated previously with vinclozolin were determined by the Keele injector, vinclozolin was found to be about 30% lower as compared to a normal method, suggesting about 70% recovery of the spiked vinclozolin by the Keele injector. From these results, the Keele injector was suggested to be potential for sample introduction in gas chromatographic analysis of vinclozolin in lettuce samples.

  1. Quality of omeprazole purchased via the Internet and personally imported into Japan: comparison with products sampled in other Asian countries.

    PubMed

    Rahman, Mohammad Sofiqur; Yoshida, Naoko; Sugiura, Sakura; Tsuboi, Hirohito; Keila, Tep; Kiet, Heng Bun; Zin, Theingi; Tanimoto, Tsuyoshi; Kimura, Kazuko

    2018-03-01

    To evaluate the quality of omeprazole personally imported into Japan via the Internet and to compare the quality of these samples with previously collected samples from two other Asian countries. The samples were evaluated by observation, authenticity investigation and pharmacopoeial quality analysis. Quality comparison of some selected samples was carried out by dissolution profiling, Raman spectroscopy and principle component analysis (PCA). Observation of the Internet sites and samples revealed some discrepancies including the delivery of a wrong sample and the selling of omeprazole without a prescription, although it is a prescription medicine. Among the 28 samples analysed, all passed the identification test, 26 (93%) passed the quantity and content uniformity tests and all passed the dissolution test. Dissolution profiling confirmed that all the personally imported omeprazole samples remained intact in the acid medium. On the other hand, six samples from two of the same manufacturers, previously collected during surveys in Cambodia and Myanmar, frequently showed premature omeprazole release in acid. Raman spectroscopy and PCA showed significant variation between omeprazole formulations in personally imported samples and the samples from Cambodia and Myanmar. Our results indicate that the pharmaceutical quality of omeprazole purchased through the Internet was sufficient, as determined by pharmacopeial tests. However, omeprazole formulations distributed in different market segments by the same manufacturers were of diverse quality. Measures are needed to ensure consistent quality of products and to prevent entry of substandard products into the legitimate supply chain. © 2018 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  2. Measuring Sulfur Isotope Ratios from Solid Samples with the Sample Analysis at Mars Instrument and the Effects of Dead Time Corrections

    NASA Technical Reports Server (NTRS)

    Franz, H. B.; Mahaffy, P. R.; Kasprzak, W.; Lyness, E.; Raaen, E.

    2011-01-01

    The Sample Analysis at Mars (SAM) instrument suite comprises the largest science payload on the Mars Science Laboratory (MSL) "Curiosity" rover. SAM will perform chemical and isotopic analysis of volatile compounds from atmospheric and solid samples to address questions pertaining to habitability and geochemical processes on Mars. Sulfur is a key element of interest in this regard, as sulfur compounds have been detected on the Martian surface by both in situ and remote sensing techniques. Their chemical and isotopic composition can belp constrain environmental conditions and mechanisms at the time of formation. A previous study examined the capability of the SAM quadrupole mass spectrometer (QMS) to determine sulfur isotope ratios of SO2 gas from a statistical perspective. Here we discuss the development of a method for determining sulfur isotope ratios with the QMS by sampling SO2 generated from heating of solid sulfate samples in SAM's pyrolysis oven. This analysis, which was performed with the SAM breadboard system, also required development of a novel treatment of the QMS dead time to accommodate the characteristics of an aging detector.

  3. Forgery at the Snite Museum of Art? Improving AMS Radiocarbon Dating at the University of Notre Dame

    NASA Astrophysics Data System (ADS)

    Troyer, Laura; Bagwell, Connor; Anderson, Tyler; Clark, Adam; Nelson, Austin; Skulski, Michael; Collon, Philippe

    2017-09-01

    The Snite Museum of Art recently obtained several donations of artifacts. Five of the pieces lack sufficient background information to prove authenticity and require further analysis to positively determine the artwork's age. One method to determine the artwork's age is radiocarbon dating via Accelerator Mass Spectrometry (AMS) performed at the University of Notre Dame's Nuclear Science Laboratory. Samples are prepared by combustion of a small amount of material and subsequent reduction to carbon into an iron powder matrix (graphitization). The graphitization procedure affects the maximum measurement rate, and a poor graphitization can be detrimental to the AMS measurement of the sample. Previous graphitization procedures resulted in a particle current too low or inconsistent to optimize AMS measurements. Thus, there was a desire to design and refine the graphitization system. The finalized process yielded physically darker samples and increased sample currents by two orders of magnitude. Additionally, the first testing of the samples was successful, yet analysis of the dates proved inconclusive. AMS measurements will be performed again to obtain better sampling statistics in the hopes of narrowing the reported date ranges. NSF and JINA-CEE.

  4. Improved sample treatment for the determination of insoluble soap in sewage sludge samples by liquid chromatography with fluorescence detection.

    PubMed

    Cantarero, Samuel; Zafra-Gómez, A; Ballesteros, O; Navalón, A; Vílchez, J L; Crovetto, G; Verge, C; de Ferrer, J A

    2010-09-15

    A new selective and sensitive method for the determination of insoluble fatty acid salts (soap) in sewage sludge samples is proposed. The method involves a clean up of sample with petroleum ether, the conversion of calcium and magnesium insoluble salts into soluble potassium salts, potassium salts extraction with methanol, and a derivatization procedure previous to the liquid chromatography with fluorescence detection (LC-FLD) analysis. Three different extraction techniques (Soxhlet, microwave-assisted extraction and ultrasounds) were compared and microwave-assisted extraction (MAE) was selected as appropriate for our purpose. This allowed to reduce the extraction time and solvent waste (50 mL of methanol in contrast with 250 mL for Soxhlet procedure). The absence of matrix effect was demonstrated with two standards (C(13:0) and C(17:0)) that are not commercials and neither of them has been detected in sewage sludge samples. Therefore, it was possible to evaluate the matrix effect since both standards have similar environmental behaviour (adsorption and precipitation) to commercial soaps (C(10:0)-C(18:0)). The method was successfully applied to samples from different sources and consequently, with different composition. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  5. A Simple Automated Method for the Determination of Nitrate and Nitrite in Infant Formula and Milk Powder Using Sequential Injection Analysis

    PubMed Central

    Pistón, Mariela; Mollo, Alicia; Knochen, Moisés

    2011-01-01

    A fast and efficient automated method using a sequential injection analysis (SIA) system, based on the Griess, reaction was developed for the determination of nitrate and nitrite in infant formulas and milk powder. The system enables to mix a measured amount of sample (previously constituted in the liquid form and deproteinized) with the chromogenic reagent to produce a colored substance whose absorbance was recorded. For nitrate determination, an on-line prereduction step was added by passing the sample through a Cd minicolumn. The system was controlled from a PC by means of a user-friendly program. Figures of merit include linearity (r2 > 0.999 for both analytes), limits of detection (0.32 mg kg−1 NO3-N, and 0.05 mg kg−1 NO2-N), and precision (sr%) 0.8–3.0. Results were statistically in good agreement with those obtained with the reference ISO-IDF method. The sampling frequency was 30 hour−1 (nitrate) and 80 hour−1 (nitrite) when performed separately. PMID:21960750

  6. Use of scleractinian corals to indicate marine pollution in the northern Gulf of Aqaba, Jordan.

    PubMed

    Barakat, S A; Al-Rousan, S; Al-Trabeen, M S

    2015-02-01

    The actual and fatal concentrations of selected heavy metals, including cadmium, cobalt, copper, lead, nickel, and zinc in corals from the Gulf of Aqaba were determined. Several living coral samples of different species (e.g., Porites) were collected from shallow depths (of about 5 m) at a number of sites along the Jordanian Gulf of Aqaba coast. The coral samples were collected using either a pneumatic diamond drill corer (for Porites) or a hammer and chisel (for other branched species). Some of the corals that had been collected were analyzed for heavy metals using atomic absorption spectrometry, and other samples were used in incubation experiments. The heavy metal concentrations were determined separately in the coral skeleton and the tissue layer. Heavy metal concentrations have not previously been determined in corals from the Gulf of Aqaba. We conclude that corals are suitable for use as proxy tools for assessing environmental pollution (i.e., they are bioindicators) in the Gulf of Aqaba and the Red Sea. Therefore, this study provides useful information on the degree of heavy metal contamination in the study area.

  7. METHODS FOR DETERMINING SMALL AMOUNTS OF NIOBIUM AND TANTALUM IN ORES (in Russian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bykova, V.S.; Skrizhinskaya, V.I.

    1960-01-01

    Several current colorimetric methods for determining Nb and Ta were evaluated by comparing the results obtained from analyzing artificial mixtures and minerals, such as loparite, tantalite-columbite, perovskite, pyrochlore, cassiterite-tantalite and Ti-bearing minerals such as sphene. A modification of the thiosulfate method had a sensitivity of 0.05% Nb and was found useful when the sample contained less than 1% Ti. The dimethyl fluorene method for Ta was sensitive to 0.002% and could be used only if most of the Ti was previously removed from the sample. The pyrogallol extraction method, based on the extraction of complex Ta fluoride wtth cyclohexane, presentedmore » a sensitivity of 0.01% of Ta, similar to the pyrogallol-tannin method used for both elements. If their concentration is smaller, the samples must be analyzed subsequently according to the first two methods. The absorption method allows a determination of the two elements without separating them, if their concentration is higher than 0.5%, although the individual sensitivity of the method is 0.05% for Ta and 0.005% for Nb. (TTT)« less

  8. Rotation-Activity Correlations in K and M Dwarfs. I. Stellar Parameters and Compilations of v sin I and P/sin I for a Large Sample of Late-K and M Dwarfs

    NASA Astrophysics Data System (ADS)

    Houdebine, E. R.; Mullan, D. J.; Paletou, F.; Gebran, M.

    2016-05-01

    The reliable determination of rotation-activity correlations (RACs) depends on precise measurements of the following stellar parameters: T eff, parallax, radius, metallicity, and rotational speed v sin I. In this paper, our goal is to focus on the determination of these parameters for a sample of K and M dwarfs. In a future paper (Paper II), we will combine our rotational data with activity data in order to construct RACs. Here, we report on a determination of effective temperatures based on the (R-I) C color from the calibrations of Mann et al. and Kenyon & Hartmann for four samples of late-K, dM2, dM3, and dM4 stars. We also determine stellar parameters (T eff, log(g), and [M/H]) using the principal component analysis-based inversion technique for a sample of 105 late-K dwarfs. We compile all effective temperatures from the literature for this sample. We determine empirical radius-[M/H] correlations in our stellar samples. This allows us to propose new effective temperatures, stellar radii, and metallicities for a large sample of 612 late-K and M dwarfs. Our mean radii agree well with those of Boyajian et al. We analyze HARPS and SOPHIE spectra of 105 late-K dwarfs, and we have detected v sin I in 92 stars. In combination with our previous v sin I measurements in M and K dwarfs, we now derive P/sin I measures for a sample of 418 K and M dwarfs. We investigate the distributions of P/sin I, and we show that they are different from one spectral subtype to another at a 99.9% confidence level. Based on observations available at Observatoire de Haute Provence and the European Southern Observatory databases and on Hipparcos parallax measurements.

  9. ROTATION–ACTIVITY CORRELATIONS IN K AND M DWARFS. I. STELLAR PARAMETERS AND COMPILATIONS OF v sin i AND P /sin i FOR A LARGE SAMPLE OF LATE-K AND M DWARFS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Houdebine, E. R.; Mullan, D. J.; Paletou, F.

    The reliable determination of rotation–activity correlations (RACs) depends on precise measurements of the following stellar parameters: T {sub eff}, parallax, radius, metallicity, and rotational speed v sin i . In this paper, our goal is to focus on the determination of these parameters for a sample of K and M dwarfs. In a future paper (Paper II), we will combine our rotational data with activity data in order to construct RACs. Here, we report on a determination of effective temperatures based on the ( R – I ){sub C} color from the calibrations of Mann et al. and Kenyon andmore » Hartmann for four samples of late-K, dM2, dM3, and dM4 stars. We also determine stellar parameters ( T {sub eff}, log( g ), and [M/H]) using the principal component analysis–based inversion technique for a sample of 105 late-K dwarfs. We compile all effective temperatures from the literature for this sample. We determine empirical radius–[M/H] correlations in our stellar samples. This allows us to propose new effective temperatures, stellar radii, and metallicities for a large sample of 612 late-K and M dwarfs. Our mean radii agree well with those of Boyajian et al. We analyze HARPS and SOPHIE spectra of 105 late-K dwarfs, and we have detected v sin i in 92 stars. In combination with our previous v sin i measurements in M and K dwarfs, we now derive P /sin i measures for a sample of 418 K and M dwarfs. We investigate the distributions of P /sin i , and we show that they are different from one spectral subtype to another at a 99.9% confidence level.« less

  10. Listeria monocytogenes incidence changes and diversity in some Brazilian dairy industries and retail products.

    PubMed

    Oxaran, Virginie; Lee, Sarah Hwa In; Chaul, Luíza Toubas; Corassin, Carlos Humberto; Barancelli, Giovana Verginia; Alves, Virgínia Farias; de Oliveira, Carlos Augusto Fernandes; Gram, Lone; De Martinis, Elaine Cristina Pereira

    2017-12-01

    Listeria monocytogenes can cause listeriosis, a severe foodborne disease. In Brazil, despite very few reported cases of listeriosis, the pathogen has been repeatedly isolated from dairies. This has led the government to implement specific legislation to reduce the hazard. Here, we determined the incidence of L. monocytogenes in five dairies and retail products in the Southeast and Midwest regions of Brazil over eight months. Of 437 samples, three samples (0.7%) from retail and only one sample (0.2%) from the dairies were positive for L. monocytogenes. Thus, the contamination rate was significantly reduced as compared to previous studies. MultiLocus Sequence Typing (MLST) was used to determine if contamination was caused by new or persistent clones leading to the first MLST profile of L. monocytogenes from the Brazilian dairy industry. The processing environment isolate is of concern being a sequence-type (ST) 2, belonging to the lineage I responsible for the majority of listeriosis outbreaks. Also, ST3 and ST8 found in commercialized cheese have previously been reported in outbreaks. Despite the lower incidence, dairy products still pose a potential health risk and the occurrence of L. monocytogenes in dairies and retail products emphasize the need for continuous surveillance of this pathogen in the Brazilian dairy industry. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Chromatographic determination of nanomolar cyanate concentrations in estuarine and sea waters by precolumn fluorescence derivatization.

    PubMed

    Widner, Brittany; Mulholland, Margaret R; Mopper, Kenneth

    2013-07-16

    Recent studies suggest that cyanate (OCN(-)) is a potentially important source of reduced nitrogen (N) available to support the growth of aquatic microbes and, thus, may play a role in aquatic N cycling. However, aquatic OCN(-) distributions have not been previously described because of the lack of a suitable assay for measuring OCN(-) concentrations in natural waters. Previous methods were designed to quantify OCN(-) in aqueous samples with much higher reduced N concentrations (micromolar levels) than those likely to be found in natural waters (nanomolar levels). We have developed a method to quantify OCN(-) in dilute, saline environments. In the method described here, OCN(-) in aqueous solution reacts with 2-aminobenzoic acid to produce a highly fluorescent derivative, 2,4-quinazolinedione, which is then quantified using high performance liquid chromatography. Derivatization conditions were optimized to simultaneously minimize the reagent blank and maximize 2,4-quinazolinedione formation (>90% reaction yield) in estuarine and seawater matrices. A limit of detection (LOD) of 0.4 nM was achieved with only minor matrix effects. We applied this method to measure OCN(-) concentrations in estuarine and seawater samples from the Chesapeake Bay and coastal waters from the mid-Atlantic region. OCN(-) concentrations ranged from 0.9 to 41 nM. We determined that OCN(-) concentrations were stable in 0.2 μm filtered seawater samples stored at -80 °C for up to nine months.

  12. Improvement of a wind-tunnel sampling system for odour and VOCs.

    PubMed

    Wang, X; Jiang, J; Kaye, R

    2001-01-01

    Wind-tunnel systems are widely used for collecting odour emission samples from surface area sources. Consequently, a portable wind-tunnel system was developed at the University of New South Wales that was easy to handle and suitable for sampling from liquid surfaces. Development work was undertaken to ensure even air-flows above the emitting surface and to optimise air velocities to simulate real situations. However, recovery efficiencies for emissions have not previously been studied for wind-tunnel systems. A series of experiments was carried out for determining and improving the recovery rate of the wind-tunnel sampling system by using carbon monoxide as a tracer gas. It was observed by mass balance that carbon monoxide recovery rates were initially only 37% to 48% from a simulated surface area emission source. It was therefore apparent that further development work was required to improve recovery efficiencies. By analysing the aerodynamic character of air movement and CO transportation inside the wind-tunnel, it was determined that the apparent poor recoveries resulted from uneven mixing at the sample collection point. A number of modifications were made for the mixing chamber of the wind-tunnel system. A special sampling chamber extension and a sampling manifold with optimally distributed sampling orifices were developed for the wind-tunnel sampling system. The simulation experiments were repeated with the new sampling system. Over a series of experiments, the recovery efficiency of sampling was improved to 83-100% with an average of 90%, where the CO tracer gas was introduced at a single point and 92-102% with an average of 97%, where the CO tracer gas was introduced along a line transverse to the sweep air. The stability and accuracy of the new system were determined statistically and are reported.

  13. Novel method for the determination of average molecular weight of natural polymers based on 2D DOSY NMR and chemometrics: Example of heparin.

    PubMed

    Monakhova, Yulia B; Diehl, Bernd W K; Do, Tung X; Schulze, Margit; Witzleben, Steffen

    2018-02-05

    Apart from the characterization of impurities, the full characterization of heparin and low molecular weight heparin (LMWH) also requires the determination of average molecular weight, which is closely related to the pharmaceutical properties of anticoagulant drugs. To determine average molecular weight of these animal-derived polymer products, partial least squares regression (PLS) was utilized for modelling of diffused-ordered spectroscopy NMR data (DOSY) of a representative set of heparin (n=32) and LMWH (n=30) samples. The same sets of samples were measured by gel permeation chromatography (GPC) to obtain reference data. The application of PLS to the data led to calibration models with root mean square error of prediction of 498Da and 179Da for heparin and LMWH, respectively. The average coefficients of variation (CVs) did not exceed 2.1% excluding sample preparation (by successive measuring one solution, n=5) and 2.5% including sample preparation (by preparing and analyzing separate samples, n=5). An advantage of the method is that the sample after standard 1D NMR characterization can be used for the molecular weight determination without further manipulation. The accuracy of multivariate models is better than the previous results for other matrices employing internal standards. Therefore, DOSY experiment is recommended to be employed for the calculation of molecular weight of heparin products as a complementary measurement to standard 1D NMR quality control. The method can be easily transferred to other matrices as well. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Evaluation of the furosine and homoarginine methods for determining reactive lysine in rumen-undegraded protein.

    PubMed

    Boucher, S E; Pedersen, C; Stein, H H; Schwab, C G

    2009-08-01

    Three samples of soybean meal (SBM), 3 samples of expeller SBM (SoyPlus, West Central Cooperative, Ralston, IA), 5 samples of distillers dried grains with solubles (DDGS), and 5 samples of fish meal were used to evaluate the furosine and homoarginine procedures to estimate reactive Lys in the rumen-undegraded protein fraction (RUP-Lys). One sample each of SBM, expeller SBM, and DDGS were subjected to additional heat treatment in the lab to ensure there was a wide range in reactive RUP-Lys content among the samples. Furosine is a secondary product of the initial stages of the Maillard reaction and can be used to calculate blocked Lys. Homoarginine is formed via the reaction of reactive Lys with O-methylisourea and can be used to calculate the concentration of reactive Lys. In previous experiments, each sample was ruminally incubated in situ for 16 h, and standardized RUP-Lys digestibility of the samples was determined in cecectomized roosters. All rumen-undegraded residue (RUR) samples were analyzed for furosine and Lys; however, only 9 of the 16 samples contained furosine, and only the 4 unheated DDGS samples contained appreciable amounts of furosine. Blocked RUP-Lys was calculated from the furosine and Lys concentrations of the RUR. Both the intact feed and RUR samples were evaluated using the homoarginine method. All samples were incubated with an O-methylisourea/BaOH solution for 72 h and analyzed for Lys and homoarginine concentrations. Reactive Lys concentrations of the intact feeds and RUR were calculated. Results of the experiment indicate that blocked RUP-Lys determined via the furosine method was negatively correlated with standardized RUP-Lys digestibility, and reactive RUP-Lys determined via the guanidination method was positively correlated with standardized RUP-Lys digestibility. Reactive Lys concentrations of the intact samples were also highly correlated with RUP-Lys digestibility. In conclusion, the furosine assay is useful in predicting RUP-Lys digestibility of DDGS samples, and the guanidination procedure can be used to predict RUP-Lys digestibility of SBM, expeller SBM, DDGS, and fish meal samples.

  15. Volatile Organic Compounds (VOCs) Measurements in Karachi, Pakistan (2006): a Comparison With Previous Urban Sampling Campaigns Worldwide.

    NASA Astrophysics Data System (ADS)

    Barletta, B.; Meinardi, S.; Khwaja, H. A.; Beyersdorf, A. J.; Baker, A. K.; Zou, S.; Rowland, F.; Blake, D. R.

    2008-12-01

    Mixing ratios of carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), and 47 nonmethane hydrocarbons - NMHCs - (19 alkanes, 13 alkenes, ethyne, and 14 aromatics) were determined for ground level whole air samples collected during the winter of 2006 in Karachi, Pakistan. Pakistan is among the fastest growing economies in Asia, and Karachi is one of the largest cities in the world with a rapidly expanding population of over 14 million in the whole metropolitan area, and a large industrial base. Samples were collected in January 2006 throughout the urban area to characterize the overall air composition of the city, and along the busiest road to determine the traffic signature of Karachi. This sampling campaign follows a previous study carried out in the winter of 1998-1999 in the same city, when elevated concentrations of many NMHCs were observed. Exceptionally high levels of methane were still observed in 2006 with an average mixing ratio of 5.0 ppmv (6.3 ppmv were observed in 1999). The overall air composition of the Karachi urban environment characterized during this 2006 sampling is compared to 1999 aiming to highlight any possible change in the main VOC sources present throughout the city. In particular, we want to evaluate the impact of the heavy usage of natural gas on the overall air quality of Karachi and the recently increased use of liquefied petroleum gas (LPG) as alternative source of energy. We also compare the composition of the urban troposphere of Karachi to other major urban centers worldwide such as Guangzhou (China), Mexico City (Mexico), and Milan (Italy).

  16. Simultaneous Determination of Procainamide and N-acetylprocainamide in Rat Plasma by Ultra-High-Pressure Liquid Chromatography Coupled with a Diode Array Detector and Its Application to a Pharmacokinetic Study in Rats.

    PubMed

    Balla, Anusha; Cho, Kwan Hyung; Kim, Yu Chul; Maeng, Han-Joo

    2018-03-30

    A simple, sensitive, and reliable reversed-phase, Ultra-High-Pressure Liquid Chromatography (UHPLC) coupled with a Diode Array Detector (DAD) method for the simultaneous determination of Procainamide (PA) and its major metabolite, N -acetylprocainamide (NAPA), in rat plasma was developed and validated. A simple deproteinization method with methanol was applied to the rat plasma samples, which were analyzed using UHPLC equipped with DAD at 280 nm, and a Synergi™ 4 µm polar, reversed-phase column using 1% acetic acid (pH 5.5) and methanol (76:24, v / v ) as eluent in isocratic mode at a flow rate 0.2 mL/min. The method showed good linearity ( r ² > 0.998) over the concentration range of 20-100,000 and 20-10,000 ng/mL for PA and NAPA, respectively. Intra- and inter-day accuracies ranged from 97.7 to 110.9%, and precision was <10.5% for PA and 99.7 to 109.2 and <10.5%, respectively, for NAPA. The lower limit of quantification was 20 ng/mL for both compounds. This is the first report of the UHPLC-DAD bioanalytical method for simultaneous measurement of PA and NAPA. The most obvious advantage of this method over previously reported HPLC methods is that it requires small sample and injection volumes, with a straightforward, one-step sample preparation. It overcomes the limitations of previous methods, which use large sample volume and complex sample preparation. The devised method was successfully applied to the quantification of PA and NAPA after an intravenous bolus administration of 10 mg/kg procainamide hydrochloride to rats.

  17. Measuring fluorescence polarization with a dichrometer.

    PubMed

    Sutherland, John C

    2017-09-01

    A method for obtaining fluorescence polarization data from an instrument designed to measure circular and linear dichroism is compared with a previously reported approach. The new method places a polarizer between the sample and a detector mounted perpendicular to the direction of the incident beam and results in determination of the fluorescence polarization ratio, whereas the previous method does not use a polarizer and yields the fluorescence anisotropy. A similar analysis with the detector located axially with the excitation beam demonstrates that there is no frequency modulated signal due to fluorescence polarization in the absence of a polarizer. Copyright © 2017. Published by Elsevier Inc.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sutherland, John C.

    In this article, a method for obtaining fluorescence polarization data from an instrument designed to measure circular and linear dichroism is compared with a previously reported approach. The new method places a polarizer between the sample and a detector mounted perpendicular to the direction of the incident beam and results in determination of the fluorescence polarization ratio, whereas the previous method does not use a polarizer and yields the fluorescence anisotropy. A similar analysis with the detector located axially with the excitation beam demonstrates that there is no frequency modulated signal due to fluorescence polarization in the absence of amore » polarizer.« less

  19. A survey of chemical constituents in National Fish Hatchery fish feed

    USGS Publications Warehouse

    Maule, Alec G.; Gannam, Ann; Davis, Jay

    2006-01-01

    Recent studies have demonstrated that various fish feeds contain significant concentrations of contaminants, many of which can bioaccumulate and bioconcentrate in fish. It appears that numerous organochlorine (OC) contaminants are present in the fish oils and fish meals used in feed manufacture, and some researchers speculate that all fish feeds contain measurable levels of some contaminants. To determine the presence and concentration of contaminants in feeds used in National Fish Hatcheries managed by the U.S. Fish & Wildlife Service, we systematically collected samples of feed from 11 hatcheries that raise cold-water species, and analyzed them for a suite of chemical contaminants. All of the samples (collected from October 2001 to October 2003) contained measurable concentrations of at least one dioxin, furan, polychlorinated biphenyl (PCB) congener, or dichlorodiphenyltrichloroethane (DDT) metabolite. All samples which were assayed for all contaminants contained one or more of those classes of compounds and most contained more than one; dioxin was detected in 39 of the 55 samples for which it was assayed, 24 of 55 contained furans and 24 of 55 samples contained DDT or its metabolites. There with 10- to 150-fold differences in the range in concentrations of the additive totals for PCBs, dioxins, furans and DDT. Although PCBs were the most commonly detected contaminant in our study (all samples in which it was assayed), the concentrations (range: 0.07 to 10.46 ng g·1 wet weight) were low compared to those reported previously. In general, we also found lower levels of organochlorine contaminants than have been reported previously in fish feed. Perhaps most notable is the near absence of OC pesticides~xcept for DDT (and its metabolites) and just two samples containing benzene hexachloride (Lindane). While contaminant concentrations were generally low, the ecological impacts can not be determined without a measure of the bioaccumulation of these compounds in the fish and the fate of these compounds after the fish are released from the hatcheries.

  20. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; in-bottle acid digestion of whole-water samples

    USGS Publications Warehouse

    Hoffman, G.L.; Fishman, M. J.; Garbarino, J.R.

    1996-01-01

    Water samples for trace-metal determinations routinely have been prepared in open laboratories. For example, the U.S. Geological Survey method I-3485-85 (Extraction Procedure, for Water- Suspended Sediment) is performed in a laboratory hood on a laboratory bench without any special precautions to control airborne contamination. This method tends to be contamination prone for several trace metals primarily because the samples are transferred, acidified, digested, and filtered in an open laboratory environment. To reduce trace-metal contamination of digested water samples, procedures were established that rely on minimizing sample-transfer steps and using a class-100 clean bench during sample filtration. This new procedure involves the following steps: 1. The sample is acidified with HCl directly in the original water-sample bottle. 2. The water-sample bottle with the cap secured is heated in a laboratory oven. 3. The digestate is filtered in a class-100 laminar-flow clean bench. The exact conditions used (that is, oven temperature, time of heating, and filtration methods) for this digestion procedure are described. Comparisons between the previous U.S Geological Survey open-beaker method I-3485-85 and the new in-bottle procedure for synthetic and field-collected water samples are given. When the new procedure is used, blank concentrations for most trace metals determined are reduced significantly.

  1. [Women's opinion on abortion legalization in a middle size county in southern Brazil].

    PubMed

    César, J A; Gomes, G; Horta, B L; de Oliveira, A K; Saraiva, A K; Pardo, D O; Silva, L M; Rodghiero, C L; Gross, M R

    1997-12-01

    Induced abortion is the main cause of maternal death in Brazil. Question of its legalization has been the subject of frequent discussion. In order to assess the influence of the variables affecting the opinion of women of reproductive age, a population-based systematic sample in the county of Rio Grande (Southern Brazil) was examined. Of a total of 1,456 interviews 30% endorsed the legalization, whatever the circumstances; this percentage was directly associated with age, schooling, family income and previous induced abortion (p < 0.01). Adjusted analysis using logistic regression showed a significant effect of schooling and previous induced abortion on favourable opinion. Schooling and previous induced abortion were the main determinants of women's favorable opinions regarding abortion legalization.

  2. Individual detection of genetically modified maize varieties in non-identity-preserved maize samples.

    PubMed

    Akiyama, Hiroshi; Sakata, Kozue; Kondo, Kazunari; Tanaka, Asako; Liu, Ming S; Oguchi, Taichi; Furui, Satoshi; Kitta, Kazumi; Hino, Akihiro; Teshima, Reiko

    2008-03-26

    In many countries, the labeling of grains and feed- and foodstuffs is mandatory if the genetically modified organism (GMO) content exceeds a certain level of approved GM varieties. The GMO content in a maize sample containing the combined-trait (stacked) GM maize as determined by the currently available methodology is likely to be overestimated. However, there has been little information in the literature on the mixing level and varieties of stacked GM maize in real sample grains. For the first time, the GMO content of non-identity-preserved (non-IP) maize samples imported from the United States has been successfully determined by using a previously developed individual kernel detection system coupled to a multiplex qualitative PCR method followed by multichannel capillary gel electrophoresis system analysis. To clarify the GMO content in the maize samples imported from the United States, determine how many stacked GM traits are contained therein, and which GM trait varieties frequently appeared in 2005, the GMO content (percent) on a kernel basis and the varieties of the GM kernels in the non-IP maize samples imported from the United States were investigated using the individual kernel analysis system. The average (+/-standard deviation) of the GMO contents on a kernel basis in five non-IP sample lots was determined to be 51.0+/-21.6%, the percentage of a single GM trait grains was 39%, and the percentage of the stacked GM trait grains was 12%. The MON810 grains and NK603 grains were the most frequent varieties in the single GM traits. The most frequent stacked GM traits were the MON810xNK603 grains. In addition, the present study would provide the answer and impact for the quantification of GM maize content in the GM maize kernels on labeling regulation.

  3. Effects of holding time and measurement error on culturing Legionella in environmental water samples.

    PubMed

    Flanders, W Dana; Kirkland, Kimberly H; Shelton, Brian G

    2014-10-01

    Outbreaks of Legionnaires' disease require environmental testing of water samples from potentially implicated building water systems to identify the source of exposure. A previous study reports a large impact on Legionella sample results due to shipping and delays in sample processing. Specifically, this same study, without accounting for measurement error, reports more than half of shipped samples tested had Legionella levels that arbitrarily changed up or down by one or more logs, and the authors attribute this result to shipping time. Accordingly, we conducted a study to determine the effects of sample holding/shipping time on Legionella sample results while taking into account measurement error, which has previously not been addressed. We analyzed 159 samples, each split into 16 aliquots, of which one-half (8) were processed promptly after collection. The remaining half (8) were processed the following day to assess impact of holding/shipping time. A total of 2544 samples were analyzed including replicates. After accounting for inherent measurement error, we found that the effect of holding time on observed Legionella counts was small and should have no practical impact on interpretation of results. Holding samples increased the root mean squared error by only about 3-8%. Notably, for only one of 159 samples, did the average of the 8 replicate counts change by 1 log. Thus, our findings do not support the hypothesis of frequent, significant (≥= 1 log10 unit) Legionella colony count changes due to holding. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Determinants of Utilization of Eye Care Services in a Rural Adult Population of a Developing Country

    PubMed Central

    Olusanya, Bolutife A.; Ashaye, Adeyinka O.; Owoaje, Eme T.; Baiyeroju, Aderonke M.; Ajayi, Benedictus G.

    2016-01-01

    Purpose: To describe the factors that determine the utilization of eye care services in a rural community in South-Western Nigeria. Methods: A descriptive cross-sectional survey using a multistage sampling technique was conducted. The main outcome measure was self-reported previous consultation of an orthodox medical facility for eye care. Results: The study sample included 643 participants. Only 122 (19%) respondents had previously visited orthodox facilities in search of eye care and 24% of those with presenting visual acuity <6/18 had sought eye care. Characteristics associated with previous utilization of eye care services were age of =70 years (odds ratio [OR] ≥ 1.7, P = 0.02); male gender (OR = 1.5, P = 0.04); literacy (OR = 1.7, P = 0.007); and residing close to an eye care facility (OR = 2.8, P < 0.001). Blind respondents were three times more likely to seek eye care (P < 0.001). Regression analysis revealed that factors associated with increased likelihood of utilization of eye care services included age ≥70 years; literacy; residence close to an eye facility; being diabetic or hypertensive; history of ocular symptoms, and blindness. Conclusions: These findings suggest that a significant proportion (75%) of adults in the study area are not utilizing eye care services and that blindness is an important determinant of utilization of eye care services. Health education and awareness campaigns about the importance and benefits of seeking eye care early, and the provision of community-based eye care programs are essential to boost the uptake of eye care services in this community as well as other rural areas of West Africa. PMID:26957847

  5. Environmental determinants of Vibrio parahaemolyticus in the Chesapeake Bay.

    PubMed

    Davis, Benjamin J K; Jacobs, John M; Davis, Meghan F; Schwab, Kellogg J; DePaola, Angelo; Curriero, Frank C

    2017-08-25

    Vibrio parahaemolyticus naturally-occurs in brackish and marine waters and is one of the leading causes of seafood-borne illness. Previous work studying the ecology of V. parahaemolyticus is often limited in geographic extent and lacking a full range of environmental measures. This study used a unique, large dataset of surface water samples in the Chesapeake Bay ( n =1,385) collected from 148 monitoring stations from 2007 to 2010. Water was analyzed for over 20 environmental parameters with additional meteorological and surrounding land use data. V. parahaemolyticus -specific genetic markers thermolabile hemolysin ( tlh ), thermostable direct hemolysin ( tdh ), and tdh -related hemolysin ( trh ) were assayed using quantitative PCR (qPCR), and interval-censored regression models with non-linear effects were estimated to account for limits of detection and quantitation. tlh was detected in 19.6% of water samples; tdh or trh markers were not detected. Results confirmed previously reported positive associations for V. parahaemolyticus abundance with temperature and turbidity and negative associations with high salinity (> 10-23‰). Furthermore, the salinity relationship was determined to be a function of both low temperature and turbidity, with an increase of either nullifying the high salinity effect. Associations with dissolved oxygen and phosphate also appeared stronger when samples were taken nearby human developments. Renewed focus on the V. parahaemolyticus ecological paradigm is warranted to protect public health. Importance Vibrio parahaemolyticus is one of the leading causes of seafood-borne illness in the United States and across the globe. Exposure is often through consuming raw or undercooked shellfish. Given the natural presence of the bacterium in the marine environment, improved understanding of its environmental determinants is necessary for future preventative measures. This analysis of environmental Vibrio parahaemolyticus is one of only a few that utilize a large dataset measured over a wide geographic and temporal range. The analysis also includes a large number of environmental parameters for Vibrio modeling, many of which have previously only been tested sporadically, and some of which have not been considered before. The results of the analysis revealed previously unknown relationships between salinity, turbidity, and temperature that provide significant insight into the abundance and persistence of V. parahaemolyticus bacterium in the environment. This information will be essential for developing environmental forecast models for the bacterium. Copyright © 2017 American Society for Microbiology.

  6. The Use of Native Speaker Norms in Critical Period Hypothesis Research

    ERIC Educational Resources Information Center

    Andringa, Sible

    2014-01-01

    In critical period hypothesis (CPH) research, native speaker (NS) norm groups have often been used to determine whether nonnative speakers (NNSs) were able to score within the NS range of scores. One goal of this article is to investigate what NS samples were used in previous CPH research. The literature review shows that NS control groups tend to…

  7. The Adoption of Blended E-Learning Technology in Vietnam Using a Revision of the Technology Acceptance Model

    ERIC Educational Resources Information Center

    Tran, Khanh Ngo Nhu

    2016-01-01

    This study examines factors that determine the attitudes of learners toward a blended e-learning system (BELS) using data collected by questionnaire from a sample of 396 students involved in a BELS environment in Vietnam. A theoretical model is derived from previous studies and is analyzed and developed using structural equation modeling…

  8. Flowering branches cause injuries to second-year main stems of Artemisia tridentata nutt. subspecies tridentata

    Treesearch

    Lance S. Evans; Angela Citta; Stewart C. Sanderson

    2012-01-01

    Eccentricity of stems of Artemisia tridentata Nutt. (big sagebrush) has been reported previously. Analysis of samples observed over 2 years documented that each stem terminal produces about 8-10 branches each year, and during second-year growth, 3-8 of these develop into short, flowering, determinate branches. Each flowering branch produces hundreds of seeds and then...

  9. Temperament, Select Home Environment Characteristics and Reading Readiness as Predictors of Reading Progress.

    ERIC Educational Resources Information Center

    Brown, T.J.

    Progress in a primary-grade reading program was determined for 106 first-born, second-grade students at the end of the school year. Previous data available for this sample included Thomas-Chase-Birch temperament ratings, family intactness and socioeconomic status at age four, and Metropolitan Readiness Test scores at age six. The value of these…

  10. A Latent Variable Approach to Determining the Structure of Executive Function in Preschool Children

    ERIC Educational Resources Information Center

    Miller, Michael R.; Giesbrecht, Gerald F.; Muller, Ulrich; McInerney, Robert J.; Kerns, Kimberly A.

    2012-01-01

    The composition of executive function (EF) in preschool children was examined using confirmatory factor analysis (CFA). A sample of 129 children between 3 and 5 years of age completed a battery of EF tasks. Using performance indicators of working memory and inhibition similar to previous CFA studies with preschoolers, we replicated a unitary EF…

  11. OPTIMIZED DETERMINATION OF TRACE JET FUEL VOLATILE ORGANIC COMPOUNDS IN HUMAN BLOOD USING IN-FIELD LIQUID-LIQUID EXTRACTION WITH SUBSEQUENT LABORATORY GAS CHROMATOGRAPHIC-MASS SPECTROMETRIC ANALYSIS AND ON-COLUMN LARGE VOLUME INJECTION

    EPA Science Inventory

    A practical and sensitive method to assess volatile organic compounds (VOCs) from JP-8 jet fuel in human whole blood was developed by modifying previously established liquid-liquid extraction procedures, optimizing extraction times, solvent volume, specific sample processing te...

  12. Chandra Observations of Three Newly Discovered Quadruply Gravitationally Lensed Quasars

    NASA Astrophysics Data System (ADS)

    Pooley, David

    2017-09-01

    Our previous work has shown the unique power of Chandra observations of quadruply gravitationally lensed quasars to address several fundamental astrophysical issues. We have used these observations to (1) determine the cause of flux ratio anomalies, (2) measure the sizes of quasar accretion disks, (3) determine the dark matter content of the lensing galaxies, and (4) measure the stellar mass-to-light ratio (in fact, this is the only way to measure the stellar mass-to-light ratio beyond the solar neighborhood). In all cases, the main source of uncertainty in our results is the small size of the sample of known quads; only 15 systems are available for study with Chandra. We propose Chandra observations of three newly discovered quads, increasing the sample size by 20%

  13. Improved microautoradiographic method to determine individual microorganisms active in substrate uptake in natural waters.

    PubMed

    Tabor, P S; Neihof, R A

    1982-10-01

    We report a method which combines epifluorescence microscopy and microautoradiography to determine both the total number of microorganisms in natural water populations and those individual organisms active in the uptake of specific substrates. After incubation with H-labeled substrate, the sample is filtered and, while still on the filter, mounted directly in a film of autoradiographic emulsion on a microscope slide. The microautoradiogram is processed and stained with acridine orange, and, subsequently, the filter is removed before microscopic observation. This novel preparation resulted in increased accuracy in direct counts made from the autoradiogram, improved sensitivity in the recognition of uptake-active (H-labeled) organisms, and enumeration of a significantly greater number of labeled organisms compared with corresponding samples prepared by a previously reported method.

  14. Improved Microautoradiographic Method to Determine Individual Microorganisms Active in Substrate Uptake in Natural Waters

    PubMed Central

    Tabor, Paul S.; Neihof, Rex A.

    1982-01-01

    We report a method which combines epifluorescence microscopy and microautoradiography to determine both the total number of microorganisms in natural water populations and those individual organisms active in the uptake of specific substrates. After incubation with 3H-labeled substrate, the sample is filtered and, while still on the filter, mounted directly in a film of autoradiographic emulsion on a microscope slide. The microautoradiogram is processed and stained with acridine orange, and, subsequently, the filter is removed before microscopic observation. This novel preparation resulted in increased accuracy in direct counts made from the autoradiogram, improved sensitivity in the recognition of uptake-active (3H-labeled) organisms, and enumeration of a significantly greater number of labeled organisms compared with corresponding samples prepared by a previously reported method. Images PMID:16346120

  15. Use of drugs of abuse in less than 30-year-old drivers killed in a road crash in France: a spectacular increase for cannabis, cocaine and amphetamines.

    PubMed

    Mura, P; Chatelain, C; Dumestre, V; Gaulier, J M; Ghysel, M H; Lacroix, C; Kergueris, M F; Lhermitte, M; Moulsma, M; Pépin, G; Vincent, F; Kintz, P

    2006-07-13

    A collaborative study was conducted in France in order to determine the prevalence of cannabinoids, opiates, cocaine metabolites and amphetamines in blood samples from drivers killed in road accidents in 2003 and 2004 and to compare these values with those of a previous study performed during the period 2000-2001 involving 900 drivers. Blood samples were provided from 2003 under 30-year-old drivers, killed in a traffic accident. Drugs of abuse were determined by gas chromatography-mass spectrometry using the same analytical procedures in all the 12 laboratories. The most frequently observed compounds were by far cannabinoids, that tested positive in 39.6% of the total number of samples. Delta9 tetrahydrocannabinol (THC), the most active of the principle constituents in marijuana (cannabis sativa), was detected in the blood of 28.9% drivers and was the single drug of abuse in 80.2% of the positive cases. It was associated with amphetamines in 7.4% and with opiates and cocaine in 1.9 and 4.8%, respectively. Amphetamines were present in 3.1% of the total number of samples, cocaine metabolites in 3.0% and opiates in 3.5%. When comparing these results with those of a previous study performed 3 years before, a significant increase is observed for THC (28.9% versus 16.9%), cocaine metabolites (3.0% versus 0.2%) and amphetamines (3.1% versus 1.4%). This study demonstrates the critical necessity of implementing in France as soon as possible systematical roadside testing for drugs of abuse.

  16. Chemical contaminants in fish feeds used in federal salmonid hatcheries in the USA

    USGS Publications Warehouse

    Maule, A.G.; Gannam, A.L.; Davis, J.W.

    2007-01-01

    Recent studies have demonstrated that fish feeds contain significant concentrations of contaminants, many of which can bioaccumulate and bioconcentrate in fish. Organochlorine (OC) contaminants are present in the fish oils and fish meals used in feed manufacture, and some researchers speculate that all fish feeds contain measurable levels of some contaminants. To determine the concentration of contaminants in feeds used in US Fish and Wildlife Service's National Fish Hatcheries, we systematically collected samples of feed from 11 cold-water fish hatcheries. All samples (collected from October 2001 to October 2003) contained at least one polychlorinated dibenzo-p-dioxin (PCDD), polychlorinated dibenzofuran (PCDF), polychlorinated biphenyl (PCB) congener, or dichlorodiphenyltrichloroethane (DDT) metabolite. Of the 55 samples in which they were analyzed 39 contained PCDDs, 24 contained PCDFs and 24 contained DDT or its metabolites. There were 10- to 150-fold differences in concentrations of total PCBs, PCDDs, PCDFs and DDT. Although PCBs were the most commonly detected contaminant in our study, concentrations (range: 0.07-10.46 ng g-1 wet weight) were low compared to those reported previously. In general, we also found lower levels of OCs than reported previously in fish feed. Perhaps most notable was the near absence of OC pesticides - except for DDT or its metabolites, and two samples containing hexachlorocyclohexane (HCH). While contaminant concentrations were generally low, the ecological impacts can not be determined without a measure of the bioaccumulation of these compounds in the fish and the fate of these compounds after the fish are released. ?? 2006 Elsevier Ltd. All rights reserved.

  17. The surface area of soil organic matter

    USGS Publications Warehouse

    Chiou, C.T.; Lee, J.-F.; Boyd, S.A.

    1990-01-01

    The previously reported surface area for soil organic matter (SOM) of 560-800 m2/g as determined by the ethylene glycol (EG) retention method was reexamined by the standard BET method based on nitrogen adsorption at liquid nitrogen temperature. Test samples consisted of two high organic content soils, a freeze-dried soil humic acid, and an oven-dried soil humic acid. The measured BET areas for these samples were less than 1 m2/g, except for the freeze-dried humic acid. The results suggest that surface adsorption of nonionic organic compounds by SOM is practically insignificant in comparison to uptake by partition. The discrepancy between the surface areas of SOM obtained by BET and EG methods was explained in terms of the 'free surface area' and the 'apparent surface area' associated with these measurements.The previously reported surface area for soil organic matter (SOM) of 560-800 m2/g as determined by the ethylene glycol (EG) retention method was reexamined by the standard BET method based on nitrogen adsorption at liquid nitrogen temperature. Test samples consisted of two high organic content soils, a freeze-dried soil humic acid, and an oven-dried soil humic acid. The measured BET areas for these samples were less than 1 m2/g, except for the freeze-dried humic acid. The results suggest that surface adsorption of nonionic organic compounds by SOM is practically insignificant in comparison to uptake by partition. The discrepancy between the surface areas of SOM obtained by BET and EG methods was explained in terms of the 'free surface area' and the 'apparent surface area' associated with these measurements.

  18. Attitudes and factors affecting acceptability of self-administered cervicovaginal sampling for human papillomavirus (HPV) genotyping as an alternative to Pap testing among multiethnic Malaysian women

    PubMed Central

    Ma'som, Mahirah; Bhoo-Pathy, Nirmala; Nasir, Nazrila Hairizan; Bellinson, Jerome; Subramaniam, Shridevi; Ma, Yuntong; Yap, Siew-Hwei; Goh, Pik-Pin; Gravitt, Patti; Woo, Yin Ling

    2016-01-01

    Objective The objective of this study was to determine the attitudes and acceptability of self-administered cervicovaginal sampling compared with conventional physician-acquired Papanicolaou (Pap) smear among multiethnic Malaysian women. Method A cross-sectional study was carried out via interviewer-administered surveys from August 2013 through August 2015 at five government-run, urban health clinics in the state of Selangor. Subjects were participants from an ongoing community-based human papillomavirus (HPV) prevalence study who answered a standard questionnaire before and after self-sampling. The cervicovaginal self-sampling for HPV genotyping was performed using a simple brush (‘Just for Me’; Preventive Oncology International, Hong Kong). Detailed data on sociodemographics, previous Pap smear experience, and attitudes towards self-administered cervicovaginal sampling were collected and analysed. Acceptability was inferred using a five-item Likert scale that included six different subjective descriptives: experience, difficulty, convenience, embarrassment, discomfort or pain, and confidence in collecting one's own sample. Results Of the 839 participants, 47.9% were Malays, followed by 30.8% Indians, 18.8% Chinese and 2.5% from other ethnicities. The median age of the participants was 38 years (IQR 30–48). Some 68.2% of participants indicated a preference for self-sampling over the Pap test, with 95% indicating willingness to follow-up a positive result at the hospital. Age, ethnicity and previous Pap test experience were significant independent factors associated with preference for self-sampling. The older the individual, the less likely they were to prefer self-sampling (adjusted OR 0.94, 95% CI 0.90 to 0.98). The Chinese were less likely to prefer self-sampling (72.6%) than the Malays (85.1%) (adjusted OR 0.57, 95% CI 0.33 to 0.98, p=0.004). Participants who had never undergone a Pap smear were also more likely to prefer self-sampling (88.5%) than women who had undergone a previous Pap (80.9%) (adjusted OR 0.06, 95% CI 0.35 to 0.87). Conclusions Overall, urban Malaysian women from multiethnic backgrounds found self-sampling to be an acceptable alternative to Pap smear. PMID:27491667

  19. Non-iterative determination of the stress-density relation from ramp wave data through a window

    NASA Astrophysics Data System (ADS)

    Dowling, Evan; Fratanduono, Dayne; Swift, Damian

    2017-06-01

    In the canonical ramp compression experiment, a smoothly-increasing load is applied the surface of the sample, and the particle velocity history is measured at interfaces two or more different distances into the sample. The velocity histories are used to deduce a stress-density relation by correcting for perturbations caused by reflected release waves, usually via the iterative Lagrangian analysis technique of Rothman and Maw. We previously described a non-iterative (recursive) method of analysis, which was more stable and orders of magnitude faster than iteration, but was subject to the limitation that the free surface velocity had to be sampled at uniform intervals. We have now developed more general recursive algorithms suitable for analyzing ramp data through a finite-impedance window. Free surfaces can be treated seamlessly, and the need for uniform velocity sampling has been removed. These calculations require interpolation of partially-released states using the partially-constructed isentrope, making them slower than the previous free-surface scheme, but they are still much faster than iterative analysis. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  20. Small-volume potentiometric titrations: EPR investigations of Fe-S cluster N2 in mitochondrial complex I.

    PubMed

    Wright, John J; Salvadori, Enrico; Bridges, Hannah R; Hirst, Judy; Roessler, Maxie M

    2016-09-01

    EPR-based potentiometric titrations are a well-established method for determining the reduction potentials of cofactors in large and complex proteins with at least one EPR-active state. However, such titrations require large amounts of protein. Here, we report a new method that requires an order of magnitude less protein than previously described methods, and that provides EPR samples suitable for measurements at both X- and Q-band microwave frequencies. We demonstrate our method by determining the reduction potential of the terminal [4Fe-4S] cluster (N2) in the intramolecular electron-transfer relay in mammalian respiratory complex I. The value determined by our method, E m7 =-158mV, is precise, reproducible, and consistent with previously reported values. Our small-volume potentiometric titration method will facilitate detailed investigations of EPR-active centres in non-abundant and refractory proteins that can only be prepared in small quantities. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Hemispherical Laue camera

    DOEpatents

    Li, James C. M.; Chu, Sungnee G.

    1980-01-01

    A hemispherical Laue camera comprises a crystal sample mount for positioning a sample to be analyzed at the center of sphere of a hemispherical, X-radiation sensitive film cassette, a collimator, a stationary or rotating sample mount and a set of standard spherical projection spheres. X-radiation generated from an external source is directed through the collimator to impinge onto the single crystal sample on the stationary mount. The diffracted beam is recorded on the hemispherical X-radiation sensitive film mounted inside the hemispherical film cassette in either transmission or back-reflection geometry. The distances travelled by X-radiation diffracted from the crystal to the hemispherical film are the same for all crystal planes which satisfy Bragg's Law. The recorded diffraction spots or Laue spots on the film thereby preserve both the symmetry information of the crystal structure and the relative intensities which are directly related to the relative structure factors of the crystal orientations. The diffraction pattern on the exposed film is compared with the known diffraction pattern on one of the standard spherical projection spheres for a specific crystal structure to determine the orientation of the crystal sample. By replacing the stationary sample support with a rotating sample mount, the hemispherical Laue camera can be used for crystal structure determination in a manner previously provided in conventional Debye-Scherrer cameras.

  2. Sampling and analysis plan for assessment of beryllium in soils surrounding TA-40 building 15

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruedig, Elizabeth

    Technical Area (TA) 40 Building 15 (40-15) is an active firing site at Los Alamos National Laboratory. The weapons facility operations (WFO) group plans to build an enclosure over the site in 2017, so that test shots may be conducted year-round. The enclosure project is described in PRID 16P-0209. 40-15 is listed on LANL OSH-ISH’s beryllium inventory, which reflects the potential for beryllium in/on soils and building surfaces at 40-15. Some areas in and around 40-15 have previously been sampled for beryllium, but past sampling efforts did not achieve complete spatial coverage of the area. This Sampling and Analysis Planmore » (SAP) investigates the area surrounding 40-15 via 9 deep (≥1-ft.) soil samples and 11 shallow (6-in.) soil samples. These samples will fill the spatial data gaps for beryllium at 40-15, and will be used to support OSH-ISH’s final determination of 40-15’s beryllium registry status. This SAP has been prepared by the Environmental Health Physics program in consultation with the Industrial Hygiene program. Industrial Hygiene is the owner of LANL’s beryllium program, and will make a final determination with regard to the regulatory status of beryllium at 40-15.« less

  3. Trace element content and magnetic properties of commercial HOPG samples studied by ion beam microscopy and SQUID magnetometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spemann, D., E-mail: spemann@uni-leipzig.de; Esquinazi, P., E-mail: esquin@physik.uni-leipzig.de; Setzer, A.

    In this study, the impurity concentration and magnetic response of nine highly oriented pyrolytic graphite (HOPG) samples with different grades and from different providers were determined using ion beam microscopy and SQUID magnetometry. Apart from sideface contaminations in the as-received state, bulk contamination of the samples in most cases consists of disk-shaped micron-sized particles made of Ti and V with an additional Fe contamination around the grain perimeter. The saturation magnetization typically increases with Fe concentration, however, there is no simple correlation between Fe content and magnetic moment. The saturation magnetization of one, respectively six, out of nine samples clearlymore » exceeds the maximum contribution from pure Fe or Fe{sub 3}C. For most samples the temperature dependence of the remanence decreases linearly with T – a dependence found previously for defect-induced magnetism (DIM) in HOPG. We conclude that apart from magnetic impurities, additional contribution to the ferromagnetic magnetization exists in pristine HOPG in agreement with previous studies. A comparative study between the results of ion beam microscopy and the commonly used EDX analysis shows clearly that EDX is not a reliable method for quantitative trace elemental analysis in graphite, clarifying weaknesses and discrepancies in the element concentrations given in the recent literature.« less

  4. Seroprevalence of viral infections in domestic cats in Costa Rica.

    PubMed

    Blanco, Kinndle; Prendas, Jorge; Cortes, Rocío; Jimenez, Carlos; Dolz, Gaby

    2009-05-01

    A cross-sectional survey of a convenient sample of domestic cats from Costa Rica's greater metropolitan area was carried out to determine the prevalence of antibodies against feline herpesvirus type 1 (FHV-1), feline parvovirus (FPV), feline immunodeficiency virus (FIV) and antigens of feline leukemia virus (FeLV). Blood samples were collected from at least 96 cats from June 1998 to December 2001; data related to the individual cats and household variables were obtained using a questionnaire. Antibodies against FHV-1 were found in 71.9% of the cats sampled, but only 25.0% of them had a history of previous vaccination. The prevalence of FPV was 92.8%, and all positive cats showed protective antibodies titres; however, only 16.5% of them were previously vaccinated. Antigens of FeLV were detected in 16.7% of the sampled cats; 11 (64.7%) of the 17 positive cats were older than 1 year at the time of testing. No differences were found between the percentage of seropositive males and females. Antibodies against FIV were detected in 8.8% of the samples tested; 8 (88.8%) of the seropositive cats were older than 1 year of age, and a greater proportion of seropositive males (66.6%) was found.

  5. Investigation of experimental pole-figure errors by simulation of individual spectra

    NASA Astrophysics Data System (ADS)

    Lychagina, T. A.; Nikolaev, D. I.

    2007-09-01

    The errors in measuring the crystallographic texture described by pole figures are studied. A set of diffraction spectra for a sample of the MA2-1 alloy (Mg + 4.5% Al + 1% Zn) are measured, simulation of individual spectra on the basis of which the pole figures were obtained is performed, and their errors are determined. The conclusion about the possibility of determining the effect of errors of the diffraction peak half-width on the pole figure errors that was drawn in our previous studies is confirmed.

  6. Near-shore and off-shore habitat use by endangered juvenile Lost River and Shortnose Suckers in Upper Klamath Lake, Oregon: 2006 data summary

    USGS Publications Warehouse

    Burdick, Summer M.; Wilkens, Alexander X.; VanderKooi, Scott P.

    2008-01-01

    We continued sampling juvenile suckers in 2006 as part of an effort to develop bioenergetics models for juvenile Lost River and shortnose suckers. This study required us to collect fish to determine growth rates and energy content of juvenile suckers. We followed the sampling protocols and methods described by Hendrixson et al. (2007b) to maintain continuity and facilitate comparisons with data collected in recent years, but sampled at a reduced level of effort compared to previous years (approximately one-third) due to limited funding. Here we present a summary of catch data collected in 2006. Bioenergetics models will be reported separately

  7. Distribution of trace elements in drilling chip samples around a roll-type uranium deposit, San Juan Basin, New Mexico

    USGS Publications Warehouse

    Day, H.C.; Spirakis, C.S.; Zech, R.S.; Kirk, A.R.

    1983-01-01

    Chip samples from rotary drilling in the vicinity of a roll-type uranium deposit in the southwestern San Juan Basin were split into a whole-washed fraction, a clay fraction, and a heavy mineral concentrate fraction. Analyses of these fractions determined that cutting samples could be used to identify geochemical halos associated with this ore deposit. In addition to showing a distribution of selenium, uranium, vanadium, and molybdenum similar to that described by Harshman (1974) in uranium roll-type deposits in Wyoming, South Dakota, and Texas, the chemical data indicate a previously unrecognized zinc anomaly in the clay fraction downdip of the uranium ore.

  8. Weapon Possession Among College Students: A Study From a Midwestern University.

    PubMed

    Jang, Hyunseok; Kang, Ji Hyon; Dierenfeldt, Rick; Lindsteadt, Greg

    2015-10-01

    Weapon possession on college campuses causes great concern, but there remains a lack of research examining the determinants of this phenomenon. Previous studies addressing weapon possession have primarily focused on either K-12 or the general adult population. Unlike previous studies, this study examined the weapon possession among college students using data collected from a mid-sized university in Missouri, and 451 students participated. Weapon possession and other theoretical factors were measured through the self-administered survey. Logistical regression analysis revealed that weapon socialization was the most significant factor in predicting student weapon carrying. Also, gender and age were significant factors in explaining campus-based weapon possession. This research has a limitation with generalizability because the data were collected from only a single university with convenient sampling. Future studies need to cover a wider range of college students from a variety of different universities with random sampling. © The Author(s) 2014.

  9. Mounting resistance of uropathogens to antimicrobial agents: A retrospective study in patients with chronic bacterial prostatitis relapse.

    PubMed

    Stamatiou, Konstantinos; Pierris, Nikolaos

    2017-07-01

    Despite recent progress in the management of chronic bacterial prostatitis (CBP), many cases relapse. Increased drug resistance patterns of responsible bacteria have been proposed as the most probable causative factor. Driven by the limited number of previous studies addressing this topic, we aimed to study whether antibiotic resistance increases in patients with CBP when relapse occurs. A secondary aim of this study was to determine the resistance patterns of responsible bacteria from patients with CBP. The study material consisted of bacterial isolates from urine and/or prostatic secretions obtained from patients with CBP. Bacterial identification was performed by using the Vitek 2 Compact system and susceptibility testing was performed by disc diffusion and/or the Vitek 2 system. Interpretation of susceptibility results was based on Clinical and Laboratory Standards Institute guidelines. A total of 253 samples from patients diagnosed with CBP for the first time (group A) and 137 samples from relapsing patients with a history of CBP and previous antibiotic treatment (group B) were analyzed. A significant reduction in bacterial resistance to the less used antibiotics (TMP-SMX, tetracyclines, aminoglycosides, penicillins, and macrolides) was noted. An increase in resistance to quinolones of many bacteria that cause CBP was also noted with the increase in resistance of enterococcus strains being alarming. Comparison of the resistance profile of CBP-responsible bacteria between samples from first-time-diagnosed patients and samples from relapsing patients revealed notable differences that could be attributed to previous antibiotic treatment.

  10. Chemical Characterization of an Envelope A Sample from Hanford Tank 241-AN-103

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hay, M.S.

    2000-08-23

    A whole tank composite sample from Hanford waste tank 241-AN-103 was received at the Savannah River Technology Center (SRTC) and chemically characterized. Prior to characterization the sample was diluted to {approximately}5 M sodium concentration. The filtered supernatant liquid, the total dried solids of the diluted sample, and the washed insoluble solids obtained from filtration of the diluted sample were analyzed. A mass balance calculation of the three fractions of the sample analyzed indicate the analytical results appear relatively self-consistent for major components of the sample. However, some inconsistency was observed between results where more than one method of determination wasmore » employed and for species present in low concentrations. A direct comparison to previous analyses of material from tank 241-AN-103 was not possible due to unavailability of data for diluted samples of tank 241-AN-103 whole tank composites. However, the analytical data for other types of samples from 241-AN-103 we re mathematically diluted and compare reasonably with the current results. Although the segments of the core samples used to prepare the sample received at SRTC were combined in an attempt to produce a whole tank composite, determination of how well the results of the current analysis represent the actual composition of the Hanford waste tank 241-AN-103 remains problematic due to the small sample size and the large size of the non-homogenized waste tank.« less

  11. Distribution and Origin of Amino Acids in Lunar Regolith Samples

    NASA Technical Reports Server (NTRS)

    Elsila, J. E.; Callahan, M. P.; Glavin, D. P.; Dworkin, J. P.; McLain, H. L.; Noble, S. K.; Gibson, E. K., Jr.

    2015-01-01

    The existence of organic compounds on the lunar surface has been a question of interest from the Apollo era to the present. Investigations of amino acids immediately after collection of lunar samples yielded inconclusive identifications, in part due to analytical limitations including insensitivity to certain compounds, an inability to separate enantiomers, and lack of compound-specific isotopic measurements. It was not possible to determine if the detected amino acids were indigenous to the lunar samples or the result of terrestrial contamination. Recently, we presented initial data from the analysis of amino acid abundances in 12 lunar regolith samples and discussed those results in the context of four potential amino acid sources [5]. Here, we expand on our previous work, focusing on amino acid abundances and distributions in seven regolith samples and presenting the first compound-specific carbon isotopic ratios measured for amino acids in a lunar sample.

  12. Determination of phthalic acid esters in different baby food samples by gas chromatography tandem mass spectrometry.

    PubMed

    Socas-Rodríguez, Bárbara; González-Sálamo, Javier; Herrera-Herrera, Antonio V; Santana-Mayor, Álvaro; Hernández-Borges, Javier

    2018-03-09

    In this work, a new method has been developed for the determination of 14 phthalic acid esters (i.e., benzylbutyl phthalate (BBP), bis-2-n-butoxyethyl phthalate (DBEP), dibutyl phthalate (DBP), dicyclohexyl phthalate (DCHP), bis-2-ethoxyethyl phthalate (DEEP), diethyl phthalate (DEP), diisodecyl phthalate (DIDP), diisononyl phthalate (DINP), bis-isopentyl phthalate (DIPP), bis (2-methoxyethyl) phthalate (DMEP), dimethyl phthalate (DMP), di-n-octyl phthalate (DNOP), bis-n-pentyl phthalate (DNPP), dipropyl phthalate (DPP)) and one adipate (bis (2-ethylhexyl) adipate (DEHA)) in different baby foods. Separation was carried out by gas chromatography triple quadrupole tandem mass spectrometry while the previous extraction of the samples was carried out using the QuEChERS method. The methodology was validated for four baby food samples (two fruit compotes of different compositions and two meat and fish purees with vegetables) using dibutyl phthalate-3,4,5,6-d 4 (DBP-d 4 ) as internal standard. Determination coefficients (R 2 ) of matrix-matched calibration curves were above 0.9922 in all cases while relative recovery values ranged between 70 and 120%, with relative standard deviation values below 19%. The limits of quantification of the method ranged between 0.03 and 1.11 μg/kg. Finally, the analysis of commercially available samples was carried out finding the presence of BBP, DEHA, DEP, DIDP, and DPP in some of the studied samples.

  13. Estuarine sediment toxicity tests on diatoms: Sensitivity comparison for three species

    NASA Astrophysics Data System (ADS)

    Moreno-Garrido, Ignacio; Lubián, Luis M.; Jiménez, Begoña; Soares, Amadeu M. V. M.; Blasco, Julián

    2007-01-01

    Experimental populations of three marine and estuarine diatoms were exposed to sediments with different levels of pollutants, collected from the Aveiro Lagoon (NW of Portugal). The species selected were Cylindrotheca closterium, Phaeodactylum tricornutum and Navicula sp. Previous experiments were designed to determine the influence of the sediment particle size distribution on growth of the species assayed. Percentage of silt-sized sediment affect to growth of the selected species in the experimental conditions: the higher percentage of silt-sized sediment, the lower growth. In any case, percentages of silt-sized sediment less than 10% did not affect growth. In general, C. closterium seems to be slightly more sensitive to the selected sediments than the other two species. Two groups of sediment samples were determined as a function of the general response of the exposed microalgal populations: three of the six samples used were more toxic than the other three. Chemical analysis of the samples was carried out in order to determine the specific cause of differences in toxicity. After a statistical analysis, concentrations of Sn, Zn, Hg, Cu and Cr (among all physico-chemical analyzed parameters), in order of importance, were the most important factors that divided the two groups of samples (more and less toxic samples). Benthic diatoms seem to be sensitive organisms in sediment toxicity tests. Toxicity data from bioassays involving microphytobentos should be taken into account when environmental risks are calculated.

  14. Development of a fast capillary electrophoresis method for determination of carbohydrates in honey samples.

    PubMed

    Rizelio, Viviane Maria; Tenfen, Laura; da Silveira, Roberta; Gonzaga, Luciano Valdemiro; Costa, Ana Carolina Oliveira; Fett, Roseane

    2012-05-15

    In this study, the determination of fructose, glucose and sucrose by capillary electrophoresis (CE) was investigated. The tendency of the analyte to undergo electromigration dispersion and the buffer capacity were evaluated using the Peakmaster(®) software and considered in the optimization of the background electrolyte, which was composed of 20 mmol L(-1) sorbic acid, 0.2 mmol L(-1) CTAB and 40 mmol L(-1) NaOH at pH 12.2. Under optimal CE conditions, the separation of the substances investigated was achieved in less than 2 min. The detection limits for the three analytes were in the range of 0.022 and 0.029 g L(-1) and precision measurements within 0.62-4.69% were achieved. The proposed methodology was applied in the quantitative analysis by direct injection of in honey samples to determine the main sugars presents. The samples were previously dissolved in deionized water and filtered with no other sample treatment. The mean values for fructose, glucose and sucrose were in the ranges of 33.65-45.46 g 100g(-1), 24.63-35.06 g 100g(-1) and <0.22-1.32 g 100g(-1), respectively. The good analytical performance of the method makes it suitable for implementation in food laboratories for the routine analysis of honey samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. STELLAR X-RAY SOURCES IN THE CHANDRA COSMOS SURVEY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wright, N. J.; Drake, J. J.; Civano, F., E-mail: nwright@cfa.harvard.ed

    2010-12-10

    We present an analysis of the X-ray properties of a sample of solar- and late-type field stars identified in the Chandra Cosmic Evolution Survey (COSMOS), a deep (160 ks) and wide ({approx}0.9 deg{sup 2}) extragalactic survey. The sample of 60 sources was identified using both morphological and photometric star/galaxy separation methods. We determine X-ray count rates, extract spectra and light curves, and perform spectral fits to determine fluxes and plasma temperatures. Complementary optical and near-IR photometry is also presented and combined with spectroscopy for 48 of the sources to determine spectral types and distances for the sample. We find distancesmore » ranging from 30 pc to {approx}12 kpc, including a number of the most distant and highly active stellar X-ray sources ever detected. This stellar sample extends the known coverage of the L{sub X}-distance plane to greater distances and higher luminosities, but we do not detect as many intrinsically faint X-ray sources compared to previous surveys. Overall the sample is typically more luminous than the active Sun, representing the high-luminosity end of the disk and halo X-ray luminosity functions. The halo population appears to include both low-activity spectrally hard sources that may be emitting through thermal bremsstrahlung, as well as a number of highly active sources in close binaries.« less

  16. Optimization of the solvent-based dissolution method to sample volatile organic compound vapors for compound-specific isotope analysis.

    PubMed

    Bouchard, Daniel; Wanner, Philipp; Luo, Hong; McLoughlin, Patrick W; Henderson, James K; Pirkle, Robert J; Hunkeler, Daniel

    2017-10-20

    The methodology of the solvent-based dissolution method used to sample gas phase volatile organic compounds (VOC) for compound-specific isotope analysis (CSIA) was optimized to lower the method detection limits for TCE and benzene. The sampling methodology previously evaluated by [1] consists in pulling the air through a solvent to dissolve and accumulate the gaseous VOC. After the sampling process, the solvent can then be treated similarly as groundwater samples to perform routine CSIA by diluting an aliquot of the solvent into water to reach the required concentration of the targeted contaminant. Among solvents tested, tetraethylene glycol dimethyl ether (TGDE) showed the best aptitude for the method. TGDE has a great affinity with TCE and benzene, hence efficiently dissolving the compounds during their transition through the solvent. The method detection limit for TCE (5±1μg/m 3 ) and benzene (1.7±0.5μg/m 3 ) is lower when using TGDE compared to methanol, which was previously used (385μg/m 3 for TCE and 130μg/m 3 for benzene) [2]. The method detection limit refers to the minimal gas phase concentration in ambient air required to load sufficient VOC mass into TGDE to perform δ 13 C analysis. Due to a different analytical procedure, the method detection limit associated with δ 37 Cl analysis was found to be 156±6μg/m 3 for TCE. Furthermore, the experimental results validated the relationship between the gas phase TCE and the progressive accumulation of dissolved TCE in the solvent during the sampling process. Accordingly, based on the air-solvent partitioning coefficient, the sampling methodology (e.g. sampling rate, sampling duration, amount of solvent) and the final TCE concentration in the solvent, the concentration of TCE in the gas phase prevailing during the sampling event can be determined. Moreover, the possibility to analyse for TCE concentration in the solvent after sampling (or other targeted VOCs) allows the field deployment of the sampling method without the need to determine the initial gas phase TCE concentration. The simplified field deployment approach of the solvent-based dissolution method combined with the conventional analytical procedure used for groundwater samples substantially facilitates the application of CSIA to gas phase studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Challenges in projecting clustering results across gene expression-profiling datasets.

    PubMed

    Lusa, Lara; McShane, Lisa M; Reid, James F; De Cecco, Loris; Ambrogi, Federico; Biganzoli, Elia; Gariboldi, Manuela; Pierotti, Marco A

    2007-11-21

    Gene expression microarray studies for several types of cancer have been reported to identify previously unknown subtypes of tumors. For breast cancer, a molecular classification consisting of five subtypes based on gene expression microarray data has been proposed. These subtypes have been reported to exist across several breast cancer microarray studies, and they have demonstrated some association with clinical outcome. A classification rule based on the method of centroids has been proposed for identifying the subtypes in new collections of breast cancer samples; the method is based on the similarity of the new profiles to the mean expression profile of the previously identified subtypes. Previously identified centroids of five breast cancer subtypes were used to assign 99 breast cancer samples, including a subset of 65 estrogen receptor-positive (ER+) samples, to five breast cancer subtypes based on microarray data for the samples. The effect of mean centering the genes (i.e., transforming the expression of each gene so that its mean expression is equal to 0) on subtype assignment by method of centroids was assessed. Further studies of the effect of mean centering and of class prevalence in the test set on the accuracy of method of centroids classifications of ER status were carried out using training and test sets for which ER status had been independently determined by ligand-binding assay and for which the proportion of ER+ and ER- samples were systematically varied. When all 99 samples were considered, mean centering before application of the method of centroids appeared to be helpful for correctly assigning samples to subtypes, as evidenced by the expression of genes that had previously been used as markers to identify the subtypes. However, when only the 65 ER+ samples were considered for classification, many samples appeared to be misclassified, as evidenced by an unexpected distribution of ER+ samples among the resultant subtypes. When genes were mean centered before classification of samples for ER status, the accuracy of the ER subgroup assignments was highly dependent on the proportion of ER+ samples in the test set; this effect of subtype prevalence was not seen when gene expression data were not mean centered. Simple corrections such as mean centering of genes aimed at microarray platform or batch effect correction can have undesirable consequences because patient population effects can easily be confused with these assay-related effects. Careful thought should be given to the comparability of the patient populations before attempting to force data comparability for purposes of assigning subtypes to independent subjects.

  18. Combining Microfluidics and Microrheology to Determine Rheological Properties of Soft Matter during Repeated Phase Transitions.

    PubMed

    Wehrman, Matthew D; Milstrey, Melissa J; Lindberg, Seth; Schultz, Kelly M

    2018-04-19

    The microstructure of soft matter directly impacts macroscopic rheological properties and can be changed by factors including colloidal rearrangement during previous phase changes and applied shear. To determine the extent of these changes, we have developed a microfluidic device that enables repeated phase transitions induced by exchange of the surrounding fluid and microrheological characterization while limiting shear on the sample. This technique is µ 2 rheology, the combination of microfluidics and microrheology. The microfluidic device is a two-layer design with symmetric inlet streams entering a sample chamber that traps the gel sample in place during fluid exchange. Suction can be applied far away from the sample chamber to pull fluids into the sample chamber. Material rheological properties are characterized using multiple particle tracking microrheology (MPT). In MPT, fluorescent probe particles are embedded into the material and the Brownian motion of the probes is recorded using video microscopy. The movement of the particles is tracked and the mean-squared displacement (MSD) is calculated. The MSD is related to macroscopic rheological properties, using the Generalized Stokes-Einstein Relation. The phase of the material is identified by comparison to the critical relaxation exponent, determined using time-cure superposition. Measurements of a fibrous colloidal gel illustrate the utility of the technique. This gel has a delicate structure that can be irreversibly changed when shear is applied. µ 2 rheology data shows that the material repeatedly equilibrates to the same rheological properties after each phase transition, indicating that phase transitions do not play a role in microstructural changes. To determine the role of shear, samples can be sheared prior to injection into our microfluidic device. µ 2 rheology is a widely applicable technique for the characterization of soft matter enabling the determination of rheological properties of delicate microstructures in a single sample during phase transitions in response to repeated changes in the surrounding environmental conditions.

  19. The Influence of Wavelength-Dependent Absorption and Temperature Gradients on Temperature Determination in Laser-Heated Diamond-Anvil Cells

    NASA Astrophysics Data System (ADS)

    Deng, J.; Lee, K. K. M.; Du, Z.; Benedetti, L. R.

    2016-12-01

    In situ temperature measurements in the laser-heated diamond-anvil cell (LHDAC) are among the most fundamental experiments undertaken in high-pressure science. Despite its importance, few efforts have been made to examine the alteration of thermal radiation spectra of hot samples by wavelength-dependent absorption of the sample itself together with temperature gradients within samples while laser heating and their influence on temperature measurement. For example, iron-bearing minerals show strong wavelength dependent absorption in the wavelength range used to determine temperature, which, together with temperature gradients can account for largely aliased apparent temperatures (e.g., 1200 K deviation for a 4000 K melting temperature) in some experiments obtained by fitting of detected thermal radiation intensities. As such, conclusions of melting temperatures, phase diagrams and partitioning behavior, may be grossly incorrect for these materials. In general, wavelength-dependent absorption and temperature gradients of samples are two key factors to consider in order to rigorously constrain temperatures, which have been largely ignored in previous LHDAC studies. A reevaluation of temperatures measured in recent high-profile papers will be reviewed.

  20. Development and validation of a matrix solid-phase dispersion method to determine acrylamide in coffee and coffee substitutes.

    PubMed

    Soares, Cristina M Dias; Alves, Rita C; Casal, Susana; Oliveira, M Beatriz P P; Fernandes, José Oliveira

    2010-04-01

    The present study describes the development and validation of a new method based on a matrix solid-phase dispersion (MSPD) sample preparation procedure followed by GC-MS for determination of acrylamide levels in coffee (ground coffee and brewed coffee) and coffee substitute samples. Samples were dispersed in C(18) sorbent and the mixture was further packed into a preconditioned custom-made ISOLUTE bilayered SPE column (C(18)/Multimode; 1 g + 1 g). Acrylamide was subsequently eluted with water, and then derivatized with bromine and quantified by GC-MS in SIM mode. The MSPD/GC-MS method presented a LOD of 5 microg/kg and a LOQ of 10 microg/kg. Intra and interday precisions ranged from 2% to 4% and 4% to 10%, respectively. To evaluate the performance of the method, 11 samples of ground and brewed coffee and coffee substitutes were simultaneously analyzed by the developed method and also by a previously validated method based in a liquid-extraction (LE) procedure, and the results were compared showing a high correlation between them.

  1. Polybrominated dibenzo-p-dioxins/ dibenzofurans and polybrominated diphenyl ethers in soil, vegetation, workshop-floor dust, and electronic shredder residue from an electronic waste recycling facility and in soils from a chemical industrial complex in eastern China.

    PubMed

    Ma, Jing; Addink, Rudolf; Yun, Sehun; Cheng, Jinping; Wang, Wenhua; Kannan, Kurunthachalam

    2009-10-01

    The formation and release of polybrominated dibenzo-p-dioxins and dibenzofurans (PBDD/Fs) from the incineration of electronic wastes (e-waste) that contain brominated flame retardants (BFRs) are a concern. However, studies on the determination of PBDD/Fs in environmental samples collected from e-waste recycling facilities are scarce. In this study, 11 2,3,7,8-substituted PBDD/Fs and 10 polybrominated diphenyl ether (PBDE) congeners were determined in electronic shredder waste, workshop-floor dust soil, and leaves (of plants on the grounds of the facility) from a large-scale e-waste recycling facility and in surface soil from a chemical-industrial complex (comprising a coke-oven plant, a coal-fired power plant, and a chlor-alkali plant) as well as agricultural areas in eastern China. Total PBDD/F concentrations in environmental samples were in the range of 113-818 pg/g dry wt (dw) for leaves, 392-18500 pg/g dw for electronic shredder residues, 716-800000 pg/g dw for soil samples, and 89600-pg/g dw for workshop-floor dust from the e-waste recycling facility and in a range from nondetect (ND) to 427 pg/g dw in soil from the chemical-industrial complex. The highest mean concentrations of total PBDD/Fs were found in soil samples and workshop-floor dust from the e-waste recycling facility. The dioxin-like toxic equivalent (measured as TEQ) concentrations of PBDD/Fs were greater than the TEQs of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) reported in our previous study for the same set of samples. The concentrations of PBDFs were several orders of magnitude higher than the concentrations of PBDDs in samples from the e-waste facility or from soil from the chemical-industrial complex. A significant correlation was found between the concentrations of sigmaPBDD/Fs and sigmaPBDEs (r = 0.769, p < 0.01) and between sigmaPBDD/Fs and the previously reported sigmaPCDD/F concentrations (r = 0.805, p < 0.01). The estimated daily human intakes of TEQs contributed by PBDD/Fs via soil/dust ingestion and dermal exposures in e-waste recycling facilities were higher than the intakes of TEQs contributed by PCDD/ Fs, calculated in our previous study.

  2. Inverse Analysis of Irradiated NuclearMaterial Gamma Spectra via Nonlinear Optimization

    NASA Astrophysics Data System (ADS)

    Dean, Garrett James

    Nuclear forensics is the collection of technical methods used to identify the provenance of nuclear material interdicted outside of regulatory control. Techniques employed in nuclear forensics include optical microscopy, gas chromatography, mass spectrometry, and alpha, beta, and gamma spectrometry. This dissertation focuses on the application of inverse analysis to gamma spectroscopy to estimate the history of pulse irradiated nuclear material. Previous work in this area has (1) utilized destructive analysis techniques to supplement the nondestructive gamma measurements, and (2) been applied to samples composed of spent nuclear fuel with long irradiation and cooling times. Previous analyses have employed local nonlinear solvers, simple empirical models of gamma spectral features, and simple detector models of gamma spectral features. The algorithm described in this dissertation uses a forward model of the irradiation and measurement process within a global nonlinear optimizer to estimate the unknown irradiation history of pulse irradiated nuclear material. The forward model includes a detector response function for photopeaks only. The algorithm uses a novel hybrid global and local search algorithm to quickly estimate the irradiation parameters, including neutron fluence, cooling time and original composition. Sequential, time correlated series of measurements are used to reduce the uncertainty in the estimated irradiation parameters. This algorithm allows for in situ measurements of interdicted irradiated material. The increase in analysis speed comes with a decrease in information that can be determined, but the sample fluence, cooling time, and composition can be determined within minutes of a measurement. Furthermore, pulse irradiated nuclear material has a characteristic feature that irradiation time and flux cannot be independently estimated. The algorithm has been tested against pulse irradiated samples of pure special nuclear material with cooling times of four minutes to seven hours. The algorithm described is capable of determining the cooling time and fluence the sample was exposed to within 10% as well as roughly estimating the relative concentrations of nuclides present in the original composition.

  3. Simultaneous determination of cocaine and opiates in dried blood spots by electrospray ionization tandem mass spectrometry.

    PubMed

    Antelo-Domínguez, Ángel; Cocho, José Ángel; Tabernero, María Jesús; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio

    2013-12-15

    A sample pre-treatment method based on blood spot collection filter cards was optimized as a means of using small volume samples for the screening and confirmation of cocaine and opiates abuse. Dried blood spots (DBSs) were prepared by dispersing 20 µL of whole blood specimens previously mixed with the internal standards (deuterated analogs of each target), and subjecting the whole DBS to extraction with 5 mL of methanol under orbital-horizontal shaking (180 rpm) for 10 min. Determinations were based on direct electrospray ionization tandem mass spectrometry (ESI-MS/MS) by injecting the re-dissolved methanol extract with the delivery solution (acetonitrile-water-formic acid, 80:19.875:0.125) at a flow rate of 60 µL min(-1), and using multiple reaction monitoring (MRM) mode with the m/z (precursor ion)→m/z (product ion) transitions for acquisition. Matrix effect has been found to be statistically significant (Multiple Range Test) when assessing cocaine, BZE, codeine and morphine, and the use of the standard addition method (dispersion of whole blood previously mixed with standards onto the filter papers) was needed for accurate determinations. The developed DBS-ESI-MS/MS procedure offered good intra-day and inter-day precisions (lower than 10% and 12%, respectively), as well as good intra-day and inter-day accuracies (inter-day absolute recoveries, expressed as the mean analytical recovery over three target concentration levels, of 103%, 100%, 101%, 98% and 100% for cocaine, BZE, codeine, morphine and 6-MAM, respectively). The high sensitivity inherent to MS/MS determinations combined with the minimal dilution of sample allowed low limits of quantification for all targets, and the developed method results therefore adequate for cocaine and opiates screening and confirmation purposes. The procedure was finally applied to DBSs prepared from whole blood from polydrug abusers, and results were compared with those obtained after a conventional sample pretreatment method based on solid phase extraction for plasma specimens and gas chromatography-mass spectrometry. © 2013 Elsevier B.V. All rights reserved.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kirtley, John R., E-mail: jkirtley@stanford.edu; Rosenberg, Aaron J.; Palmstrom, Johanna C.

    Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the size of the field sensitive area and the spacing between this area and the sample surface. In this paper we describe scanning SQUID susceptometers that achieve sub-micron spatial resolution while retaining a white noise floor flux sensitivity of ≈2μΦ{sub 0}/Hz{sup 1/2}. This high spatial resolution is accomplished by deep sub-micron feature sizes, well shielded pickup loops fabricated using a planarized process, and a deep etch step that minimizes themore » spacing between the sample surface and the SQUID pickup loop. We describe the design, modeling, fabrication, and testing of these sensors. Although sub-micron spatial resolution has been achieved previously in scanning SQUID sensors, our sensors not only achieve high spatial resolution but also have integrated modulation coils for flux feedback, integrated field coils for susceptibility measurements, and batch processing. They are therefore a generally applicable tool for imaging sample magnetization, currents, and susceptibilities with higher spatial resolution than previous susceptometers.« less

  5. Rb-Sr and Sm-Nd Isotopic Studies of Lunar Green and Orange Glasses

    NASA Technical Reports Server (NTRS)

    Shih, C.-Y.; Nyquist, L. E.; Reese, Y.

    2012-01-01

    Lunar volcanic glassy beads have been considered as quenched basaltic magmas derived directly from deep lunar mantle during fire-fountaining eruptions [1]. Since these sub-mm size glassy melt droplets were cooled in a hot gaseous medium during free flight [2], they have not been subject to mineral fractionations. Thus, they represent primary magmas and are the best samples for the investigation of the lunar mantle. Previously, we presented preliminary Rb- Sr and Sm-Nd isotopic results for green and orange glassy samples from green glass clod 15426,63 and orange soil 74220,44, respectively [3]. Using these isotopic data, initial Sr-87/Sr-86 and Nd ratios for these pristine mare glass sources can be calculated from their respective crystallization ages previously determined by other age-dating techniques. These isotopic data were used to evaluate the mineralogy of the mantle sources. In this report, we analyzed additional glassy samples in order to further characterize isotopic signatures of their source regions. Also, we'll postulate a relationship between these two major mare basalt source mineralogies in the context of lunar magma ocean dynamics.

  6. Determinants of abortion among clients coming for abortion service at felegehiwot referral hospital, northwest Ethiopia: a case control study.

    PubMed

    Tilahun, Fikreselassie; Dadi, Abel Fekadu; Shiferaw, Getachew

    2017-01-01

    According to the World Health Organization (WHO) estimate, one-third of pregnancies end in miscarriage, stillbirth, or induced abortion in the world. There are various reasons for a woman to seek induced abortion. However, limited information is available so far in the country and particularly in the study area. Therefore, the aim of the current study was to identify the determinants of induced abortion among clients coming for abortion care services at Bahirdar Felegehiwote referral hospital, Northwest Ethiopia. Institutional based unmatched case-control study was conducted from September to December 2014. Interview administered questioner was used to collect primary data. Enumeration and systematic random sampling (K = 3) method was used to select 175 cases and 350 controls. A binary logistic regression model was fitted to identify determinant factors. Odds ratio with 95% CI was computed to assess the strength and significance of the association. All sampled cases and controls were actually interviewed. The likelihood of abortion was higher among non-married women [AOR: 18.23, 95% CI: 8.04, 41.32], students [AOR: 11.46, 95% CI: 6.29, 20.87], and women having a monthly income of less than 500 ETB [AOR: 11.46, 95% CI: 6.29, 20.87]. However, the likelihood of abortion was lower among women age greater than 24 years [AOR: 0.29, 95% CI: 0.11, 0.79] and who had the previous history of induced abortion [AOR: 0.31, 95% CI: 0.15, 0.65]. The study identified being non-married, student, women age less than 24 years, having the previous history of induced abortion, and low monthly income as an independent determinant of induced abortion. Interventions focused on the identified determinant factors are recommended.

  7. Unit Costs of Interlibrary Loans and Photocopies at a Regional Medical Library: Preliminary Report *

    PubMed Central

    Spencer, Carol C.

    1970-01-01

    Unit costs of providing interlibrary loans and photocopies were determined by a method not previously used for library cost studies: random time sampling with self-observation. The working time of all appropriate personnel was sampled using Random Alarm Mechanisms and a structured checklist of tasks. The total lender's unit cost per request received, including direct labor, materials, fringe benefits, and overhead, was $1.526 for originals mailed postpaid by lender, and $1.534 for photocopies mailed. Corresponding unit costs per request filled were: originals, $1.932, and photocopies, $1.763. PMID:5439910

  8. Searching for HLA-DRB1*1206 in volunteer marrow donors in four US population groups.

    PubMed

    Lazaro, A M; Steiner, N K; Cao, K; Slack, R; Chen, D S; Xiao, Y; Beduhn, E; Ng, J; Hartzman, R J; Hurley, C K

    2006-11-01

    The frequencies of DRB1*12 alleles were determined in four US population groups by DNA sequencing. Only DRB1*120101 (or DRB1*1206 or *1210) and DRB1*120201 alleles were identified, the latter primarily in the Asian American population. Additional testing of a subset of samples to detect the presence of DRB1*1206 found all of the alleles to be DRB1*120101 (or DRB1*1210). Retesting of six samples previously typed as DRB1*1206 found only DRB1*120101 (or DRB1*1210).

  9. Panoramic radiographic survey of hypodontia in Australian Defence Force recruits.

    PubMed

    Lynham, A

    1990-02-01

    Comprehensive dental examinations and panoramic radiographs were used to determine the prevalence of hypodontia in 662 Australian Defence Force recruits. Of the sampled population, 6.3 per cent exhibited some degree of hypodontia (third molar agenesis excluded). Previous studies produced similar results. Third molar agenesis occurred in 22.7 per cent of the sample which again is in agreement with other studies. There was no statistical difference between the sexes in third molar agenesis; however, there was a significant difference with upper second premolars. Females exhibited an extremely low incidence of absence of maxillary lateral incisors.

  10. Improved formula for continuous-wave measurements of ultrasonic phase velocity

    NASA Technical Reports Server (NTRS)

    Chern, E. J.; Cantrell, J. H., Jr.; Heyman, J. S.

    1981-01-01

    An improved formula for continuous-wave ultrasonic phase velocity measurements using contact transducers is derived from the transmission line theory. The effect of transducer-sample coupling bonds is considered for measurements of solid samples even though it is often neglected because of the difficulty of accurately determining the bond thickness. Computer models show that the present formula is more accurate than previous expressions. Laboratory measurements using contacting transducers with the present formula are compared to measurements using noncontacting (hence effectively correction-free) capacitive transducers. The results of the experiments verify the validity and accuracy of the new formula.

  11. Solid-phase microextraction of methadone in urine samples by electrochemically co-deposited sol-gel/Cu nanocomposite fiber.

    PubMed

    Mohammadiazar, Sirwan; Hasanli, Fateme; Maham, Mehdi; Payami Samarin, Somayeh

    2017-08-01

    Electrochemically co-deposited sol-gel/Cu nanocomposites have been introduced as a novel, simple and single-step technique for preparation of solid-phase microextraction (SPME) coating to extract methadone (MDN) (a synthetic opioid) in urine samples. The porous surface structure of the sol-gel/Cu nanocomposite coating was revealed by scanning electron microscopy. Direct immersion SPME followed by HPLC-UV determination was employed. The factors influencing the SPME procedure, such as the salt content, desorption solvent type, pH and equilibration time, were optimized. The best conditions were obtained with no salt content, acetonitrile as desorption solvent type, pH 9 and 10 min equilibration time. The calibration graphs for urine samples showed good linearity. The detection limit was about 0.2 ng mL -1 . Also, the novel method for preparation of nanocomposite fiber was compared with previously reported techniques for MDN determination. The results show that the novel nanocomposite fiber has relatively high extraction efficiency. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Nitrate and Nitrite Determination in Gunshot Residue Samples by Capillary Electrophoresis in Acidic Run Buffer.

    PubMed

    Erol, Özge Ö; Erdoğan, Behice Y; Onar, Atiye N

    2017-03-01

    Simultaneous determination of nitrate and nitrite in gunshot residue has been conducted by capillary electrophoresis using an acidic run buffer (pH 3.5). In previously developed capillary electrophoretic methods, alkaline pH separation buffers were used where nitrite and nitrate possess similar electrophoretic mobility. In this study, the electroosmotic flow has been reversed by using low pH running buffer without any additives. As a result of reversing the electroosmotic flow, very fast analysis has been actualized, well-defined and separated ion peaks emerge in less than 4 min. Besides, the limit of detection was improved by employing large volume sample stacking. Limit of detection values were 6.7 and 4.3 μM for nitrate and nitrite, respectively. In traditional procedure, mechanical agitation is employed for extraction, while in this work the extraction efficiency of ultrasound mixing for 30 min was found sufficient. The proposed method was successfully applied to authentic gunshot residue samples. © 2016 American Academy of Forensic Sciences.

  13. Automatic energy calibration algorithm for an RBS setup

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silva, Tiago F.; Moro, Marcos V.; Added, Nemitala

    2013-05-06

    This work describes a computer algorithm for automatic extraction of the energy calibration parameters from a Rutherford Back-Scattering Spectroscopy (RBS) spectrum. Parameters like the electronic gain, electronic offset and detection resolution (FWHM) of a RBS setup are usually determined using a standard sample. In our case, the standard sample comprises of a multi-elemental thin film made of a mixture of Ti-Al-Ta that is analyzed at the beginning of each run at defined beam energy. A computer program has been developed to extract automatically the calibration parameters from the spectrum of the standard sample. The code evaluates the first derivative ofmore » the energy spectrum, locates the trailing edges of the Al, Ti and Ta peaks and fits a first order polynomial for the energy-channel relation. The detection resolution is determined fitting the convolution of a pre-calculated theoretical spectrum. To test the code, data of two years have been analyzed and the results compared with the manual calculations done previously, obtaining good agreement.« less

  14. An examination of the validity of the Academic Motivation Scale with a United States business student sample.

    PubMed

    Smith, Kenneth J; Davy, Jeanette A; Rosenberg, Donald L

    2010-04-01

    This study examined alternative seven-, five-, and three-factor structures for the Academic Motivation Scale, with data from a large convenience sample of 2,078 students matriculating in various business courses at three AACSB-accredited regional comprehensive universities. In addition, the invariance of the scale's factor structure between male and female students and between undergraduate and Master's of Business Administration students was investigated. Finally, the internal consistency of the items loading on each of the seven AMS subscales was assessed as well as whether the correlations among the subscales supported a continuum of self-determination. Results for the full sample as well as the targeted subpopulations supported the seven factor configuration of the scale with adequate model fit achieved for all but the MBA student group. The data also generated acceptable internal consistency statistics for all of the subscales. However, in line with a number of previous studies, the correlations between subscales failed to fully support the scale's simplex structure as proposed by self-determination theory.

  15. 14CO2 analysis of soil gas: Evaluation of sample size limits and sampling devices

    NASA Astrophysics Data System (ADS)

    Wotte, Anja; Wischhöfer, Philipp; Wacker, Lukas; Rethemeyer, Janet

    2017-12-01

    Radiocarbon (14C) analysis of CO2 respired from soils or sediments is a valuable tool to identify different carbon sources. The collection and processing of the CO2, however, is challenging and prone to contamination. We thus continuously improve our handling procedures and present a refined method for the collection of even small amounts of CO2 in molecular sieve cartridges (MSCs) for accelerator mass spectrometry 14C analysis. Using a modified vacuum rig and an improved desorption procedure, we were able to increase the CO2 recovery from the MSC (95%) as well as the sample throughput compared to our previous study. By processing series of different sample size, we show that our MSCs can be used for CO2 samples of as small as 50 μg C. The contamination by exogenous carbon determined in these laboratory tests, was less than 2.0 μg C from fossil and less than 3.0 μg C from modern sources. Additionally, we tested two sampling devices for the collection of CO2 samples released from soils or sediments, including a respiration chamber and a depth sampler, which are connected to the MSC. We obtained a very promising, low process blank for the entire CO2 sampling and purification procedure of ∼0.004 F14C (equal to 44,000 yrs BP) and ∼0.003 F14C (equal to 47,000 yrs BP). In contrast to previous studies, we observed no isotopic fractionation towards lighter δ13C values during the passive sampling with the depth samplers.

  16. Simultaneous determination of thirteen different steroid hormones using micro UHPLC-MS/MS with on-line SPE system.

    PubMed

    Márta, Zoltán; Bobály, Balázs; Fekete, Jenő; Magda, Balázs; Imre, Tímea; Mészáros, Katalin Viola; Bálint, Mária; Szabó, Pál Tamás

    2018-02-20

    Ultratrace analysis of sample components requires excellent analytical performance in terms of limits of quantitation (LOQ). Micro UHPLC coupled to sensitive tandem mass spectrometry provides state of the art solution for such analytical problems. Using on-line SPE with column switching on a micro UHPLC-MS/MS system allowed to decrease LOQ without any complex sample preparation protocol. The presented method is capable of reaching satisfactory low LOQ values for analysis of thirteen different steroid molecules from human plasma without the most commonly used off-line SPE or compound derivatization. Steroids were determined by using two simple sample preparation methods, based on lower and higher plasma steroid concentrations. In the first method, higher analyte concentrations were directly determined after protein precipitation with methanol. The organic phase obtained from the precipitation was diluted with water and directly injected into the LC-MS system. In the second method, low steroid levels were determined by concentrating the organic phase after steroid extraction. In this case, analytes were extracted with ethyl acetate and reconstituted in 90/10 water/acetonitrile following evaporation to dryness. This step provided much lower LOQs, outperforming previously published values. The method has been validated and subsequently applied to clinical laboratory measurement. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. UPLC-MS/MS determination of ptaquiloside and pterosin B in preserved natural water.

    PubMed

    Clauson-Kaas, Frederik; Hansen, Hans Christian Bruun; Strobel, Bjarne W

    2016-11-01

    The naturally occurring carcinogen ptaquiloside and its degradation product pterosin B are found in water leaching from bracken stands. The objective of this work is to present a new sample preservation method and a fast UPLC-MS/MS method for quantification of ptaquiloside and pterosin B in environmental water samples, employing a novel internal standard. A faster, reliable, and efficient method was developed for isolation of high purity ptaquiloside and pterosin B from plant material for use as analytical standards, with purity verified by 1 H-NMR. The chemical analysis was performed by cleanup and preconcentration of samples with solid phase extraction, before analyte quantification with UPLC-MS/MS. By including gradient elution and optimizing the liquid chromatography mobile phase buffer system, a total run cycle of 5 min was achieved, with method detection limits, including preconcentration, of 8 and 4 ng/L for ptaquiloside and pterosin B, respectively. The use of loganin as internal standard improved repeatability of the determination of both analytes, though it could not be employed for sample preparation. Buffering raw water samples in situ with ammonium acetate to pH ∼5.5 decisively increased sample integrity at realistic transportation and storing conditions prior to extraction. Groundwater samples collected in November 2015 at the shallow water table below a Danish bracken stand were preserved and analyzed using the above methods, and PTA concentrations of 3.8 ± 0.24 μg/L (±sd, n = 3) were found, much higher than previously reported. Graphical abstract Workflow overview of ptaquiloside determination.

  18. Simplified sample preparation method for triclosan and methyltriclosan determination in biota and foodstuff samples.

    PubMed

    Canosa, P; Rodríguez, I; Rubí, E; Ramil, M; Cela, R

    2008-04-25

    An improved method for the determination of triclosan (TCS) and methyltriclosan (MTCS) in fish and foodstuff samples is presented. Analytes were simultaneously extracted and purified using the matrix solid-phase dispersion (MSPD) technique, and then selectively determined by gas chromatography with tandem mass spectrometry (GC-MS/MS). Several combinations of dispersants, clean-up co-sorbents and extraction solvents were tested in order to obtain lipid-free extracts and quantitative recoveries for TCS and MTCS. Under optimised conditions, 0.5 g samples were dispersed using 1.5 g of neutral silica in a mortar with a pestle, and transferred to a polypropylene cartridge containing 3 g of silica impregnated with 10% of sulphuric acid (SiO2-H2SO4, 10%, w/w). Analytes were recovered with 10 mL of dichloromethane whereas lipids were oxidized in the layer of acidic silica. The extract was concentrated to dryness and re-constituted with 1 mL of ethyl acetate. Then, a fraction of 0.5 mL was mixed with 50 microL of N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA) and injected in the GC-MS/MS system. The developed method provided absolute recoveries between 77 and 120% for different samples spiked at the low ng g(-1) level, quantification limits in the range of 1-2 ng g(-1) and a considerable simplicity in comparison with previously developed sample preparation approaches. Experiments carried out placing sliced food samples in direct contact with TCS-treated kitchenware surfaces showed the capability of the biocide to migrate into foodstuffs.

  19. Diabetic eye disease among adults in Fiji with previously undiagnosed diabetes.

    PubMed

    Brian, Garry; Sikivou, Biu; Fischer-Harder, Konstanze; Szetu, John; Qoqonokana, Mundi Qalo; Ramke, Jacqueline

    2011-01-01

    To determine the prevalence and severity of diabetic eye disease among adults aged ≥40 years with unrecognized diabetes in Fiji. Population-based cross-sectional survey using multistage cluster random sampling. 1381 (=73.0% participation). Interview-based questionnaire; visual acuity measured; dilated ocular examination performed; glycosylated haemoglobin (HbA1c) concentration determined. Prevalence and grade of diabetic retinopathy/maculopathy. Sample prevalence of diabetes was 44.8% (95%CI 42.2-47.5%), with 63.4% (95%CI 59.5-67.1%) previously undiagnosed (384/606). Predictors of undiagnosed compared with previously diagnosed diabetes were female gender (P = 0.001), rural residence (P = 0.049) and not having a relative with known diabetes (P < 0.001). Twenty-two retinae of participants with previously undiagnosed diabetes were unexaminable (predominantly cataract). Of the remaining 746 eyes, 3.5% (95%CI 2.4-5.1%) had diabetic retinopathy/maculopathy, 1 (0.1%) had proliferative retinopathy and 4 (0.5%) had active significant maculopathy. Of eyes with diabetic disease, two (7.7%, 95%CI 1.0-25.3%) had diabetes-related vision impairment (3/60; 6/60). Sixteen previously undiagnosed participants (4.2%, 95%CI 2.5-6.7%) had diabetic disease evident in at least one eye: for four (all Melanesian women aged >50 years), this was vision-threatening (1.0%; 95%CI 0.3-2.8). Mean HbA1c (10.7 ± 2.6%) of participants undiagnosed and with diabetes eye disease was higher (P < 0.001) than that of those undiagnosed and without. The prevalence of diabetic eye disease was low among this cohort, but where present, severe vision-threatening retinopathy/maculopathy was relatively common. If diabetic eye disease is to be avoided or ameliorated in Fiji, then community awareness of and access to diabetes diagnostic services must improve, particularly for women and rural dwellers. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.

  20. Comparability among four invertebrate sampling methods and two multimetric indexes, Fountain Creek Basin, Colorado, 2010–2012

    USGS Publications Warehouse

    Bruce, James F.; Roberts, James J.; Zuellig, Robert E.

    2018-05-24

    The U.S. Geological Survey (USGS), in cooperation with Colorado Springs City Engineering and Colorado Springs Utilities, analyzed previously collected invertebrate data to determine the comparability among four sampling methods and two versions (2010 and 2017) of the Colorado Benthic Macroinvertebrate Multimetric Index (MMI). For this study, annual macroinvertebrate samples were collected concurrently (in space and time) at 15 USGS surface-water gaging stations in the Fountain Creek Basin from 2010 to 2012 using four sampling methods. The USGS monitoring project in the basin uses two of the methods and the Colorado Department of Public Health and Environment recommends the other two. These methods belong to two distinct sample types, one that targets single habitats and one that targets multiple habitats. The study results indicate that there are significant differences in MMI values obtained from the single-habitat and multihabitat sample types but methods from each program within each sample type produced comparable values. This study also determined that MMI values calculated by different versions of the Colorado Benthic Macroinvertebrate MMI are indistinguishable. This indicates that the Colorado Department of Public Health and Environment methods are comparable with the USGS monitoring project methods for single-habitat and multihabitat sample types. This report discusses the direct application of the study results to inform the revision of the existing USGS monitoring project in the Fountain Creek Basin.

  1. The Adaptive Response to Intestinal Oxidative Stress in Mammalian Hibernation

    DTIC Science & Technology

    2003-10-24

    redox status and pro- and anti- oxidant enzymes . a) Determination of oxidized lipids in intestinal mucosa: The tissue samples for these studies...hibernation season or between hibernating and summer squirrels. However, a strong trend was observed for lowest values of both enzyme activities in...depression involves moderate release of ROS that are detoxified by GSH-related enzymes . Although seemingly paradoxical, we have previously observed

  2. Teacher Attrition in the USA: The Relational Elements in a Utah Case Study

    ERIC Educational Resources Information Center

    Newberry, Melissa; Allsop, Yvonne

    2017-01-01

    Previous work on teacher attrition in the US has indicated that those who stay in the profession and those who leave are not separate homogenous groups. In this study, the lived experience of former teachers is examined to determine the issues that distinguish leavers from stayers. The sample is from the state of Utah, a state with one of the…

  3. Spectrophotometric determination of boric acid in boron powder with curcumin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grotheer, E.W.

    1979-12-01

    A rapid and accurate method was needed to determine trace amounts of boric acid for quality control and specification testing of elemental boron. The reaction between boric acid and curcumin occurs at a measurable rate only when the curcumin molecule is protonated. Protonation takes place at the carbonyl groups in the presence of a strong acid and occurs completely and rapidly when sulfuric acid is added to a solution of curcumin in acetic acid. Spectrophotometric measurements were made. The extraction of boric acid from boron powder was found to be complete within 2h when either water or the diol solutionmore » was used. Whatman No. 40 cr 42 filter paper was used to obtain diol samples free of boron particles. The extraction efficiency of 2-ethyl-1,3-hexanediol was evaluated by adding 1 ml of 500 ppM aqueous boric acid and 1 drop of 10% NaOH to accurately weighed samples of boron powder. The water then was evaporated at room temperature and the samples were extracted with diol solution. The data obtained are included. The extraction efficiency also was evaluated by determining the boric acid content of boron which had been recovered from a previous extraction and boric acid determination. The determination of boric acid using curcumin is unaffected by the presence of other compounds, except for fluoride and nitrate ions. 2 tables. (DP)« less

  4. CA II TRIPLET SPECTROSCOPY OF SMALL MAGELLANIC CLOUD RED GIANTS. III. ABUNDANCES AND VELOCITIES FOR A SAMPLE OF 14 CLUSTERS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parisi, M. C.; Clariá, J. J.; Marcionni, N.

    2015-05-15

    We obtained spectra of red giants in 15 Small Magellanic Cloud (SMC) clusters in the region of the Ca ii lines with FORS2 on the Very Large Telescope. We determined the mean metallicity and radial velocity with mean errors of 0.05 dex and 2.6 km s{sup −1}, respectively, from a mean of 6.5 members per cluster. One cluster (B113) was too young for a reliable metallicity determination and was excluded from the sample. We combined the sample studied here with 15 clusters previously studied by us using the same technique, and with 7 clusters whose metallicities determined by other authorsmore » are on a scale similar to ours. This compilation of 36 clusters is the largest SMC cluster sample currently available with accurate and homogeneously determined metallicities. We found a high probability that the metallicity distribution is bimodal, with potential peaks at −1.1 and −0.8 dex. Our data show no strong evidence of a metallicity gradient in the SMC clusters, somewhat at odds with recent evidence from Ca ii triplet spectra of a large sample of field stars. This may be revealing possible differences in the chemical history of clusters and field stars. Our clusters show a significant dispersion of metallicities, whatever age is considered, which could be reflecting the lack of a unique age–metallicity relation in this galaxy. None of the chemical evolution models currently available in the literature satisfactorily represents the global chemical enrichment processes of SMC clusters.« less

  5. Determination of ranges for reporting pollen aeroallergen levels in the Washington, DC, metropolitan area.

    PubMed

    Kosisky, Susan E; Marks, Mariko S; Yacovone, Margaret A; Nelson, Michael R

    2011-09-01

    Local aeroallergen monitoring provides useful information for the atopic patient and medical community. Currently, National Allergy Bureau (NAB) ranges are used for reporting pollen count levels in the Washington, DC, area. To determine standard range criteria (low, moderate, high, and very high) for the reporting of specific tree, grass, and weed aeroallergens representative of the Washington, DC, metropolitan region. Atmospheric sampling for pollen aeroallergens was performed using a volumetric rotating-arm impaction sampler (model 40 Rotorod, SDI Company, Plymouth Meeting, PA). The cumulative pollen count, over a 12-year period (1998-2009), was determined for specific pollen aeroallergens. Local ranges were developed using methodology previously employed to determine NAB ranges. A comparison was made between NAB and Washington, DC, area ranges. The local median count, and low and moderate range criteria, are markedly lower than NAB range counts for tree, grass, and weed pollen. The NAB 99th percentile (high) count is significantly higher for grass and weed pollen but lower for tree pollen. Using new local range criteria, an increase was seen in the number of high days recorded for weed pollen (1,300%), grass pollen (258.6%), and tree pollen (11.8%). Previously, using NAB range criteria, no very high days were reported for grass and weed pollen over the 12-year period. Washington, DC, ranges establish more relevant reporting standards for our local patient population and will allow for comparison with reporting levels developed for sampling locations nationwide as well as with other regional sites. Copyright © 2011 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  6. Volatile methyl siloxanes (VMS) concentrations in outdoor air of several Catalan urban areas

    NASA Astrophysics Data System (ADS)

    Gallego, E.; Perales, J. F.; Roca, F. J.; Guardino, X.; Gadea, E.

    2017-04-01

    Volatile methyl siloxanes (VMS) were evaluated in ten Catalan urban areas with different industrial impacts, such as petrochemical industry, electrical and mechanical equipment, metallurgical and chemical industries, municipal solid waste treatment plant and cement and food industries, during 2013-2015. 24 h samples were taken with LCMA-UPC pump samplers specially designed in our laboratory, with a flow range of 70 ml min-1. A sorbent-based sampling method, successfully developed to collect a wide-range of VOC, was used. The analysis was performed by automatic thermal desorption coupled with capillary gas chromatography/mass spectrometry detector. The presented methodology allows the evaluation of VMS together with a wide range of other VOC, increasing the number of compounds that can be determined in outdoor air quality assessment of urban areas. This aspect is especially relevant as a restriction of several VMS (D4 and D5) in consumer products has been made by the European Chemicals Agency and US EPA is evaluating to include D4 in the Toxic Substances Control Act, regarding the concern of the possible effects of these compounds in human health and the environment. ΣVMS concentrations (L2-L5, D3-D6 and trimethylsilanol) varied between 0.3 ± 0.2 μg m-3 and 18 ± 12 μg m-3, determined in a hotspot area. Observed VMS concentrations were generally of the same order of magnitude than the previously determined in Barcelona, Chicago and Zurich urban areas, but higher than the published from suburban sites and Arctic locations. Cyclic siloxanes concentrations were up to two-three orders of magnitude higher than those of linear siloxanes, accounting for average contributions to the total concentrations of 97 ± 6% for all samples except for the hotspot area, where cyclic VMS accounted for 99.9 ± 0.1%. D5 was the most abundant siloxane in 5 sampling points; however, differing from the generally observed in previous studies, D3 was the most abundant compound in the other 5 sampling points.

  7. High-throughput method based on quick, easy, cheap, effective, rugged and safe followed by liquid chromatography-multi-wavelength detection for the quantification of multiclass polyphenols in wines.

    PubMed

    Fontana, Ariel R; Bottini, Rubén

    2014-05-16

    In this work, a reliable, simple, fast, inexpensive and robust sample preparation approach for the determination of multiclass polyphenols in wine samples is proposed. The polyphenols selected for this work were gallic acid, (+)-catechin, (-)-epicatechin, caffeic acid, syringic acid, coumaric acid, ferulic acid, trans-resveratrol, quercetin and cinnamic acid. The method is based on QuEChERS (quick, easy, cheap, effective, rugged and safe) extraction technique coupled with dispersive solid-phase extraction (d-SPE) clean-up. Under optimized conditions, the analytes were extracted from 5mL wine samples (previously acidified with 1% formic acid) using 2.5mL acetonitrile. For phase separation, 1.5g NaCl and 4g anhydrous MgSO4 were added. Then, a 1mL aliquot of the partitioned supernatant was cleaned-up using d-SPE with a combination of 150mg CaCl2, 50mg primary-secondary amine (PSA) and 50mgC18 as sorbents. A 250μL aliquot of the obtained cleaned extract was concentrated to dryness and taken up with the initial mobile phase previous to liquid chromatography-multi-wavelength detection (LC-MWD). The proposed method provided limits of detection (LODs) ranging from 0.004 to 0.079μgmL(-1) and an inter-day variability below 12% RSD for all analytes in red and white wine samples. Considering external calibration (red wines) and matrix-matched calibration (white wines) as quantification techniques, the overall recoveries (accuracy) of the method ranged between 75.0% and 119.6% for red and white wine samples, respectively. The developed method was applied for the determination of polyphenols in 10 wines produced in Argentina. Nine phenolic compounds were determined, at concentrations above detectable levels in the method. The maximum concentrations corresponded to (-)-epicatechin in white wines, while gallic acid and (+)-catechin were the most abundant in red wines. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Sensory evaluation and electronic tongue analysis for sweetener recognition in coke drinks

    NASA Astrophysics Data System (ADS)

    Szöllősi, Dániel; Kovács, Zoltán; Gere, Attila; Sípos, László; Kókai, Zoltán; Fekete, András

    2011-09-01

    Consumption of beverages with low energy has an increasing role. Furthermore hydrolyzed starch products such as inverted syrup show a wide application in the beverage industry. Therefore the importance of methods which can monitor the usage of natural and artificial sweeteners is increasing. The task was to describe the relevant sensory attributes and to determine the applicability of the electronic tongue to discriminate the coke drink samples with different sweeteners. Furthermore the aim was to find relationship between the taste attributes and measurement results provided by electronic tongue. An Alpha Astree Electronic Tongue and a trained sensory panel were used to evaluate the coke samples. Panelists found significant differences between the samples in 15 cases from the 18 sensory attributes defined previously by the consensus group. Coke drinks containing different kind of sweeteners can be characterized according to these sensory attributes. The samples were definitely distinguished by the electronic tongue. The main difference was found between the samples made with natural and artificial sweeteners. However electronic tongue was able to distinguish samples containing different kind of artificial and different kind of natural sweeteners, as well. Taste attributes of coke drinks determined by sensory panel were predicted by partial least squares regression method based on the results of electronic tongue with close correlation and low prediction error.

  9. A flux extraction device to measure the magnetic moment of large samples; application to bulk superconductors.

    PubMed

    Egan, R; Philippe, M; Wera, L; Fagnard, J F; Vanderheyden, B; Dennis, A; Shi, Y; Cardwell, D A; Vanderbemden, P

    2015-02-01

    We report the design and construction of a flux extraction device to measure the DC magnetic moment of large samples (i.e., several cm(3)) at cryogenic temperature. The signal is constructed by integrating the electromotive force generated by two coils wound in series-opposition that move around the sample. We show that an octupole expansion of the magnetic vector potential can be used conveniently to treat near-field effects for this geometrical configuration. The resulting expansion is tested for the case of a large, permanently magnetized, type-II superconducting sample. The dimensions of the sensing coils are determined in such a way that the measurement is influenced by the dipole magnetic moment of the sample and not by moments of higher order, within user-determined upper bounds. The device, which is able to measure magnetic moments in excess of 1 A m(2) (1000 emu), is validated by (i) a direct calibration experiment using a small coil driven by a known current and (ii) by comparison with the results of numerical calculations obtained previously using a flux measurement technique. The sensitivity of the device is demonstrated by the measurement of flux-creep relaxation of the magnetization in a large bulk superconductor sample at liquid nitrogen temperature (77 K).

  10. Measuring fluorescence polarization with a dichrometer

    DOE PAGES

    Sutherland, John C.

    2017-04-06

    In this article, a method for obtaining fluorescence polarization data from an instrument designed to measure circular and linear dichroism is compared with a previously reported approach. The new method places a polarizer between the sample and a detector mounted perpendicular to the direction of the incident beam and results in determination of the fluorescence polarization ratio, whereas the previous method does not use a polarizer and yields the fluorescence anisotropy. A similar analysis with the detector located axially with the excitation beam demonstrates that there is no frequency modulated signal due to fluorescence polarization in the absence of amore » polarizer.« less

  11. Results of the Radiological Survey of the Iowa Army Ammunition Plant, Middletown, Iowa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murray, M.E.

    2001-07-17

    At the request of the U.S. Department of Energy (DOE), a team from Oak Ridge National Laboratory conducted an indoor radiological survey of property at the Iowa Army Ammunition Plant (IAAAP), Middletown, Iowa in June 2000. The purpose of the survey was to determine if radioactive residuals resulting from previous Atomic Energy Commission (AEC) activities were present inside selected Line 1 buildings at the IAAAP and conduct sampling in those areas of previous AEC operations that utilized radioactive components at some point during the manufacturing process, in order to evaluate any possible immediate health hazards and to collect sufficient informationmore » to determine the next type of survey. The AEC occupied portions of IAAAP from 1947 to 1975 to assemble nuclear weapons. The surveyed areas were identified through interviews with current and former IAAAP employees who had worked at the plant during AEC's tenure, and from AEC records.« less

  12. Branching fraction measurement of J / ψ → K S K L and search for J / ψ → K S K S

    DOE PAGES

    Ablikim, M.; Achasov, M. N.; Ahmed, S.; ...

    2017-12-04

    Using a sample of 1.31×10 9J/ψ events collected with the BESIII detector at the BEPCII collider, we study the decays of J/ψ→ K SK L and K SK S. The branching fraction of J/ψ→ K SK L is determined to be B(J/ψ→ K SK L) = (1:93 0:01 (stat:) 0:05 (syst:))×10 -4, which signi cantly improves on previous measurements. No clear signal is observed for the J/ψ→ K SK S process, and the upper limit at the 95% con dence level for its branching fraction is determined to be B(J= ! K SK S) < 1:4×10 -8, which improves onmore » the previous searches by 2 orders in magnitude and reaches the order of the Einstein-Podolsky-Rosen expectation.« less

  13. Branching fraction measurement of J / ψ → K S K L and search for J / ψ → K S K S

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ablikim, M.; Achasov, M. N.; Ahmed, S.

    Using a sample of 1.31×10 9J/ψ events collected with the BESIII detector at the BEPCII collider, we study the decays of J/ψ→ K SK L and K SK S. The branching fraction of J/ψ→ K SK L is determined to be B(J/ψ→ K SK L) = (1:93 0:01 (stat:) 0:05 (syst:))×10 -4, which signi cantly improves on previous measurements. No clear signal is observed for the J/ψ→ K SK S process, and the upper limit at the 95% con dence level for its branching fraction is determined to be B(J= ! K SK S) < 1:4×10 -8, which improves onmore » the previous searches by 2 orders in magnitude and reaches the order of the Einstein-Podolsky-Rosen expectation.« less

  14. Fatigue of die cast zinc alloys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schrems, K.K.; Dogan, O.N.; Goodwin, F.E.

    2006-04-01

    The rotating bending fatigue limit of die cast zinc alloy 2, alloy 3, alloy 5, AcuZinc 5, and ZA-8 were determined as a part of an on-going program by ILZRO into the mechanical properties of die cast zinc. The stress-life (S-N) curves of alloys 3, 5, AcuZinc 5, and ZA-8 were determined previously. This presentation reports the results of the S-N curve for Alloy 2 and the calculated fatigue limits for all five alloys. During the previous stress-life testing, the samples were stopped at 10 million cycles and the fatigue limit for alloy 3, alloy 5, and AcuZinc 5 appearedmore » to be higher and the fatigue limit for ZA-8 appeared to be lower than the values reported in the literature. This was further investigated in alloy 5 and ZA-8 by testing continuous cast bulk alloy 5 and ZA-8.« less

  15. PREVALENCE OF ANTIBODIES TO HUMAN PARVOVIRUS B19 IN SAUDI WOMEN OF CHILDBEARING AGE IN MAKKAH

    PubMed Central

    Ghazi, Hani O.

    2007-01-01

    Objectives: To determine the seroprevalence rate of immunoglobulin G (IgG) and immunoglobulin M (IgM) to parvovirus B19 in pregnant Saudi women in Makkah. Subjects and Methods: Using enzyme-linked immunosorbent assay (ELISA), a total of 1200 serum samples were tested for antibodies to parvovirus B19 known to cause a variety of clinical syndromes in women and newborn infants. Results: Parvovirus B19 IgG antibodies detected in 46.6% and IgM antibodies were found in 2.25% of different age groups. Conclusion: The previous exposure to parvovirus B19 was determined, and 560 (46.6%) of 1200 pregnant Saudi women tested at their first antenatal visit were seropositive for specific IgG. The rate of maternal infection in susceptible pregnancies was 2.25%. These results were in accordance with previous studies performed in other countries. PMID:23012138

  16. An expanded maize gene expression atlas based on RNA sequencing and its use to explore root development

    DOE PAGES

    Stelpflug, Scott C.; Sekhon, Rajandeep S.; Vaillancourt, Brieanne; ...

    2015-12-30

    Comprehensive and systematic transcriptome profiling provides valuable insight into biological and developmental processes that occur throughout the life cycle of a plant. We have enhanced our previously published microarray-based gene atlas of maize ( Zea mays L.) inbred B73 to now include 79 distinct replicated samples that have been interrogated using RNA sequencing (RNA-seq). The current version of the atlas includes 50 original array-based gene atlas samples, a time-course of 12 stalk and leaf samples postflowering, and an additional set of 17 samples from the maize seedling and adult root system. The entire dataset contains 4.6 billion mapped reads, withmore » an average of 20.5 million mapped reads per biological replicate, allowing for detection of genes with lower transcript abundance. As the new root samples represent key additions to the previously examined tissues, we highlight insights into the root transcriptome, which is represented by 28,894 (73.2%) annotated genes in maize. Additionally, we observed remarkable expression differences across both the longitudinal (four zones) and radial gradients (cortical parenchyma and stele) of the primary root supported by fourfold differential expression of 9353 and 4728 genes, respectively. Among the latter were 1110 genes that encode transcription factors, some of which are orthologs of previously characterized transcription factors known to regulate root development in Arabidopsis thaliana (L.) Heynh., while most are novel, and represent attractive targets for reverse genetics approaches to determine their roles in this important organ. As a result, this comprehensive transcriptome dataset is a powerful tool toward understanding maize development, physiology, and phenotypic diversity.« less

  17. An expanded maize gene expression atlas based on RNA sequencing and its use to explore root development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stelpflug, Scott C.; Sekhon, Rajandeep S.; Vaillancourt, Brieanne

    Comprehensive and systematic transcriptome profiling provides valuable insight into biological and developmental processes that occur throughout the life cycle of a plant. We have enhanced our previously published microarray-based gene atlas of maize ( Zea mays L.) inbred B73 to now include 79 distinct replicated samples that have been interrogated using RNA sequencing (RNA-seq). The current version of the atlas includes 50 original array-based gene atlas samples, a time-course of 12 stalk and leaf samples postflowering, and an additional set of 17 samples from the maize seedling and adult root system. The entire dataset contains 4.6 billion mapped reads, withmore » an average of 20.5 million mapped reads per biological replicate, allowing for detection of genes with lower transcript abundance. As the new root samples represent key additions to the previously examined tissues, we highlight insights into the root transcriptome, which is represented by 28,894 (73.2%) annotated genes in maize. Additionally, we observed remarkable expression differences across both the longitudinal (four zones) and radial gradients (cortical parenchyma and stele) of the primary root supported by fourfold differential expression of 9353 and 4728 genes, respectively. Among the latter were 1110 genes that encode transcription factors, some of which are orthologs of previously characterized transcription factors known to regulate root development in Arabidopsis thaliana (L.) Heynh., while most are novel, and represent attractive targets for reverse genetics approaches to determine their roles in this important organ. As a result, this comprehensive transcriptome dataset is a powerful tool toward understanding maize development, physiology, and phenotypic diversity.« less

  18. Optimization of microwave-assisted extraction with saponification (MAES) for the determination of polybrominated flame retardants in aquaculture samples.

    PubMed

    Fajar, N M; Carro, A M; Lorenzo, R A; Fernandez, F; Cela, R

    2008-08-01

    The efficiency of microwave-assisted extraction with saponification (MAES) for the determination of seven polybrominated flame retardants (polybrominated biphenyls, PBBs; and polybrominated diphenyl ethers, PBDEs) in aquaculture samples is described and compared with microwave-assisted extraction (MAE). Chemometric techniques based on experimental designs and desirability functions were used for simultaneous optimization of the operational parameters used in both MAES and MAE processes. Application of MAES to this group of contaminants in aquaculture samples, which had not been previously applied to this type of analytes, was shown to be superior to MAE in terms of extraction efficiency, extraction time and lipid content extracted from complex matrices (0.7% as against 18.0% for MAE extracts). PBBs and PBDEs were determined by gas chromatography with micro-electron capture detection (GC-muECD). The quantification limits for the analytes were 40-750 pg g(-1) (except for BB-15, which was 1.43 ng g(-1)). Precision for MAES-GC-muECD (%RSD < 11%) was significantly better than for MAE-GC-muECD (%RSD < 20%). The accuracy of both optimized methods was satisfactorily demonstrated by analysis of appropriate certified reference material (CRM), WMF-01.

  19. Specific extraction of chromium as tetrabutylammonium-chromate and spectrophotometric determination by diphenylcarbazide: speciation of chromium in effluent streams.

    PubMed

    Noroozifar, M; Khorasani-Motlagh, M

    2003-05-01

    A very specific, selective, simple, and inexpensive procedure was developed for the speciation of CrVI and CrIII. This method is based on the quantitative extraction of chromate and CrIII (previously oxidized to CrVI) as a tetrabutylammonium-chromate ion-pair in methyl isobutyl ketone (MIBK), and then back extraction and preconcentration with an acidic diphenylcarbazide (DPC) solution. Back extraction was applied to achieve further preconcentration by a final factor of 20. The CrVI-DPC complex was determined in back-extract by a spectrophotometer at 548 nm. Under these extraction conditions, most of the probable concomitant cations and anions remained in the first inorganic phase. The calibration curve was linear up to 0.14 microg L(-1) of CrVI with a detection limit of 2.22 ng L(-1). The developed procedure was found to be suitable for the determination of the CrVI and CrIII species in various natural water samples with a relative standard deviation of better than 1.6%. The method was successfully applied to the speciation of chromium in spiked natural water samples, and also samples of effluent from a leather treatment plant.

  20. Structure of catalase determined by MicroED

    PubMed Central

    Nannenga, Brent L; Shi, Dan; Hattne, Johan; Reyes, Francis E; Gonen, Tamir

    2014-01-01

    MicroED is a recently developed method that uses electron diffraction for structure determination from very small three-dimensional crystals of biological material. Previously we used a series of still diffraction patterns to determine the structure of lysozyme at 2.9 Å resolution with MicroED (Shi et al., 2013). Here we present the structure of bovine liver catalase determined from a single crystal at 3.2 Å resolution by MicroED. The data were collected by continuous rotation of the sample under constant exposure and were processed and refined using standard programs for X-ray crystallography. The ability of MicroED to determine the structure of bovine liver catalase, a protein that has long resisted atomic analysis by traditional electron crystallography, demonstrates the potential of this method for structure determination. DOI: http://dx.doi.org/10.7554/eLife.03600.001 PMID:25303172

  1. Reproducibility of Cognitive Profiles in Psychosis Using Cluster Analysis.

    PubMed

    Lewandowski, Kathryn E; Baker, Justin T; McCarthy, Julie M; Norris, Lesley A; Öngür, Dost

    2018-04-01

    Cognitive dysfunction is a core symptom dimension that cuts across the psychoses. Recent findings support classification of patients along the cognitive dimension using cluster analysis; however, data-derived groupings may be highly determined by sampling characteristics and the measures used to derive the clusters, and so their interpretability must be established. We examined cognitive clusters in a cross-diagnostic sample of patients with psychosis and associations with clinical and functional outcomes. We then compared our findings to a previous report of cognitive clusters in a separate sample using a different cognitive battery. Participants with affective or non-affective psychosis (n=120) and healthy controls (n=31) were administered the MATRICS Consensus Cognitive Battery, and clinical and community functioning assessments. Cluster analyses were performed on cognitive variables, and clusters were compared on demographic, cognitive, and clinical measures. Results were compared to findings from our previous report. A four-cluster solution provided a good fit to the data; profiles included a neuropsychologically normal cluster, a globally impaired cluster, and two clusters of mixed profiles. Cognitive burden was associated with symptom severity and poorer community functioning. The patterns of cognitive performance by cluster were highly consistent with our previous findings. We found evidence of four cognitive subgroups of patients with psychosis, with cognitive profiles that map closely to those produced in our previous work. Clusters were associated with clinical and community variables and a measure of premorbid functioning, suggesting that they reflect meaningful groupings: replicable, and related to clinical presentation and functional outcomes. (JINS, 2018, 24, 382-390).

  2. Molecular characterization of faba bean necrotic yellows viruses in Tunisia.

    PubMed

    Kraberger, Simona; Kumari, Safaa G; Najar, Asma; Stainton, Daisy; Martin, Darren P; Varsani, Arvind

    2018-03-01

    Faba bean necrotic yellows virus (FBNYV) (genus Nanovirus; family Nanoviridae) has a genome comprising eight individually encapsidated circular single-stranded DNA components. It has frequently been found infecting faba bean (Vicia faba L.) and chickpea (Cicer arietinum L.) in association with satellite molecules (alphasatellites). Genome sequences of FBNYV from Azerbaijan, Egypt, Iran, Morocco, Spain and Syria have been determined previously and we now report the first five genome sequences of FBNYV and associated alphasatellites from faba bean sampled in Tunisia. In addition, we have determined the genome sequences of two additional FBNYV isolates from chickpea plants sampled in Syria and Iran. All individual FBNYV genome component sequences that were determined here share > 84% nucleotide sequence identity with FBNYV sequences available in public databases, with the DNA-M component displaying the highest degree of diversity. As with other studied nanoviruses, recombination and genome component reassortment occurs frequently both between FBNYV genomes and between genomes of nanoviruses belonging to other species.

  3. Adequacy of Using a Three-Item Questionnaire to Determine Zygosity in Chinese Young Twins.

    PubMed

    Ho, Connie Suk-Han; Zheng, Mo; Chow, Bonnie Wing-Yin; Wong, Simpson W L; Lim, Cadmon K P; Waye, Mary M Y

    2017-03-01

    The present study examined the adequacy of a three-item parent questionnaire in determining the zygosity of young Chinese twins and whether there was any association between parent response accuracy and some demographic variables. The sample consisted of 334 pairs of same-sex Chinese twins aged from 3 to 11 years. Three scoring methods, namely the summed score, logistic regression, and decision tree, were employed to evaluate parent response accuracy of twin zygosity based on single nucleotide polymorphism (SNP) information. The results showed that all three methods achieved high level of accuracy ranging from 91 to 93 % which was comparable to the accuracy rates in previous Chinese twin studies. Correlation results also showed that the higher the parents' education level or the family income was, the more likely parents were able to tell correctly that their twins are identical or fraternal. The present findings confirmed the validity of using a three-item parent questionnaire to determine twin zygosity in a Chinese school-aged twin sample.

  4. Levels of organophosphorus pesticides in medicinal plants commonly consumed in Iran

    PubMed Central

    2012-01-01

    The frequent occurrence of pesticide residues in herbal materials was indicated by previous studies. In this study, the concentration of some of the organophosphorus pesticides including parathion, malathion, diazinon and pirimiphos methyl in different kinds of medicinal plants were determined. The samples were collected randomly from ten local markets of different areas of Iran. At the detection limit of 0.5 ng g-1, parathion and pirimiphos methyl were not detected in any of the samples. Some amounts of malathion and diazinon were found in Zataria, Matricaria chamomile, Spearmint and Cumin Seed samples while, the concentrations of target organophosphorus pesticides in Borage samples were below the detection limits of the methods which could be a result of intensive transformation of organophosphorus pesticides by Borage. In addition the organophosphorus pesticides were detected in all of the samples below the maximum residue levels (MRLs) proposed by the international organizations. PMID:23351610

  5. Composite Sampling Approaches for Bacillus anthracis Surrogate Extracted from Soil

    PubMed Central

    France, Brian; Bell, William; Chang, Emily; Scholten, Trudy

    2015-01-01

    Any release of anthrax spores in the U.S. would require action to decontaminate the site and restore its use and operations as rapidly as possible. The remediation activity would require environmental sampling, both initially to determine the extent of contamination (hazard mapping) and post-decon to determine that the site is free of contamination (clearance sampling). Whether the spore contamination is within a building or outdoors, collecting and analyzing what could be thousands of samples can become the factor that limits the pace of restoring operations. To address this sampling and analysis bottleneck and decrease the time needed to recover from an anthrax contamination event, this study investigates the use of composite sampling. Pooling or compositing of samples is an established technique to reduce the number of analyses required, and its use for anthrax spore sampling has recently been investigated. However, use of composite sampling in an anthrax spore remediation event will require well-documented and accepted methods. In particular, previous composite sampling studies have focused on sampling from hard surfaces; data on soil sampling are required to extend the procedure to outdoor use. Further, we must consider whether combining liquid samples, thus increasing the volume, lowers the sensitivity of detection and produces false negatives. In this study, methods to composite bacterial spore samples from soil are demonstrated. B. subtilis spore suspensions were used as a surrogate for anthrax spores. Two soils (Arizona Test Dust and sterilized potting soil) were contaminated and spore recovery with composites was shown to match individual sample performance. Results show that dilution can be overcome by concentrating bacterial spores using standard filtration methods. This study shows that composite sampling can be a viable method of pooling samples to reduce the number of analysis that must be performed during anthrax spore remediation. PMID:26714315

  6. Technical note: Alternatives to reduce adipose tissue sampling bias.

    PubMed

    Cruz, G D; Wang, Y; Fadel, J G

    2014-10-01

    Understanding the mechanisms by which nutritional and pharmaceutical factors can manipulate adipose tissue growth and development in production animals has direct and indirect effects in the profitability of an enterprise. Adipocyte cellularity (number and size) is a key biological response that is commonly measured in animal science research. The variability and sampling of adipocyte cellularity within a muscle has been addressed in previous studies, but no attempt to critically investigate these issues has been proposed in the literature. The present study evaluated 2 sampling techniques (random and systematic) in an attempt to minimize sampling bias and to determine the minimum number of samples from 1 to 15 needed to represent the overall adipose tissue in the muscle. Both sampling procedures were applied on adipose tissue samples dissected from 30 longissimus muscles from cattle finished either on grass or grain. Briefly, adipose tissue samples were fixed with osmium tetroxide, and size and number of adipocytes were determined by a Coulter Counter. These results were then fit in a finite mixture model to obtain distribution parameters of each sample. To evaluate the benefits of increasing number of samples and the advantage of the new sampling technique, the concept of acceptance ratio was used; simply stated, the higher the acceptance ratio, the better the representation of the overall population. As expected, a great improvement on the estimation of the overall adipocyte cellularity parameters was observed using both sampling techniques when sample size number increased from 1 to 15 samples, considering both techniques' acceptance ratio increased from approximately 3 to 25%. When comparing sampling techniques, the systematic procedure slightly improved parameters estimation. The results suggest that more detailed research using other sampling techniques may provide better estimates for minimum sampling.

  7. External quality-assurance results for the National Atmospheric Deposition Program/National Trends Network during 1991

    USGS Publications Warehouse

    Nilles, M.A.; Gordon, J.D.; Schroder, L.J.; Paulin, C.E.

    1995-01-01

    The U.S. Geological Survey used four programs in 1991 to provide external quality assurance for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN). An intersite-comparison program was used to evaluate onsite pH and specific-conductance determinations. The effects of routine sample handling, processing, and shipping of wet-deposition samples on analyte determinations and an estimated precision of analyte values and concentrations were evaluated in the blind-audit program. Differences between analytical results and an estimate of the analytical precision of four laboratories routinely measuring wet deposition were determined by an interlaboratory-comparison program. Overall precision estimates for the precipitation-monitoring system were determined for selected sites by a collocated-sampler program. Results of the intersite-comparison program indicated that 93 and 86 percent of the site operators met the NADP/NTN accuracy goal for pH determinations during the two intersite-comparison studies completed during 1991. The results also indicated that 96 and 97 percent of the site operators met the NADP/NTN accuracy goal for specific-conductance determinations during the two 1991 studies. The effects of routine sample handling, processing, and shipping, determined in the blind-audit program indicated significant positive bias (a=.O 1) for calcium, magnesium, sodium, potassium, chloride, nitrate, and sulfate. Significant negative bias (or=.01) was determined for hydrogen ion and specific conductance. Only ammonium determinations were not biased. A Kruskal-Wallis test indicated that there were no significant (*3t=.01) differences in analytical results from the four laboratories participating in the interlaboratory-comparison program. Results from the collocated-sampler program indicated the median relative error for cation concentration and deposition exceeded eight percent at most sites, whereas the median relative error for sample volume, sulfate, and nitrate concentration at all sites was less than four percent. The median relative error for hydrogen ion concentration and deposition ranged from 4.6 to 18.3 percent at the four sites and as indicated in previous years of the study, was inversely proportional to the acidity of the precipitation at a given site. Overall, collocated-sampling error typically was five times that of laboratory error estimates for most analytes.

  8. Occurrence of aflatoxin M₁ in commercial pasteurized milk samples in Sari, Mazandaran province, Iran.

    PubMed

    Mohammadi, Hamidreza; Shokrzadeh, Mohammad; Aliabadi, Zahra; Riahi-Zanjani, Bamdad

    2016-05-01

    The frequency and levels of aflatoxin M1 (AFM1) in pasteurized milk samples in Sari, located in Mazandaran province, Iran, were determined by enzyme immunoassay. Seventy-six samples of pasteurized milk from different retail stores were randomly collected over four seasons during the year 2015. AFM1 contamination was detected in all milk samples. The mean concentration of aflatoxin M1 was 65.8 ng/l, with a range of 11.7-106.6 ng/l. The highest AFM1 level was detected in milk samples collected during spring. Forty-six (60.53 %) samples had AFM1 levels that exceeded the maximum acceptable levels (50 ng/l) recommended by the European Union (EU). Comparison of these results with previously published data for AFM1 in milk in Iran shows that the percentage of samples exceeding the EU maximum level is consistently high over the years, indicating a general problem related to AFB1 contamination in dairy feedingstuff.

  9. Improved argument-FFT frequency offset estimation for QPSK coherent optical Systems

    NASA Astrophysics Data System (ADS)

    Han, Jilong; Li, Wei; Yuan, Zhilin; Li, Haitao; Huang, Liyan; Hu, Qianggao

    2016-02-01

    A frequency offset estimation (FOE) algorithm based on fast Fourier transform (FFT) of the signal's argument is investigated, which does not require removing the modulated data phase. In this paper, we analyze the flaw of the argument-FFT algorithm and propose a combined FOE algorithm, in which the absolute of frequency offset (FO) is accurately calculated by argument-FFT algorithm with a relatively large number of samples and the sign of FO is determined by FFT-based interpolation discrete Fourier transformation (DFT) algorithm with a relatively small number of samples. Compared with the previous algorithms based on argument-FFT, the proposed one has low complexity and can still effectively work with a relatively less number of samples.

  10. Holding effects on coliform enumeration in drinking water samples.

    PubMed Central

    McDaniels, A E; Bordner, R H; Gartside, P S; Haines, J R; Brenner, K P; Rankin, C C

    1985-01-01

    Standard procedures for analyzing drinking water stress the need to adhere to the time and temperature conditions recommended for holding samples collected for microbiological testing. The National Drinking Water Laboratory Certification Program requires compliance with these holding limits, but some investigators have reported difficulties in meeting them. Research was conducted by standard analytical methods to determine if changes occurred when samples were held at 5 and 22 degrees C and analyzed at 0, 24, 30, and 48 h. Samples were analyzed for coliforms by the membrane filter and fermentation-tube procedures and for heterotrophs by the pour plate method. A total of 17 treated water samples were collected from a large municipal distribution system from August to December 1981, and 12 samples were collected from January to May 1983. The samples were dosed with coliforms previously isolated from the water system, Enterobacter cloacae in 1981 and Citrobacter freundii in 1983. The coliform counts declined linearly over time, and the rates of decline were significant at both 5 and 22 degrees C. Within 24 h at 22 degrees C, levels of E. cloacae and C. freundii decreased by 47 and 26%, respectively, and at 5 degrees C, E. cloacae numbers declined by 23%. Results from these representative laboratory-grown coliforms reinforced those previously obtained with naturally occurring coliforms under the same experimental conditions. Significantly, some samples with initially unacceptable counts (greater than 4/100 ml) met the safe drinking water limits after storage at 24 h at 5 and 22 degrees C and would have been classified as satisfactory.(ABSTRACT TRUNCATED AT 250 WORDS) Images PMID:4083877

  11. Multi-Center Evaluation of the Fully Automated PCR-Based Idylla™ KRAS Mutation Assay for Rapid KRAS Mutation Status Determination on Formalin-Fixed Paraffin-Embedded Tissue of Human Colorectal Cancer

    PubMed Central

    Solassol, Jérôme; Vendrell, Julie; Märkl, Bruno; Haas, Christian; Bellosillo, Beatriz; Montagut, Clara; Smith, Matthew; O’Sullivan, Brendan; D’Haene, Nicky; Le Mercier, Marie; Grauslund, Morten; Melchior, Linea Cecilie; Burt, Emma; Cotter, Finbarr; Stieber, Daniel; Schmitt, Fernando de Lander; Motta, Valentina; Lauricella, Calogero; Colling, Richard; Soilleux, Elizabeth; Fassan, Matteo; Mescoli, Claudia; Collin, Christine; Pagès, Jean-Christophe; Sillekens, Peter

    2016-01-01

    Since the advent of monoclonal antibodies against epidermal growth factor receptor (EGFR) in colorectal cancer therapy, the determination of RAS mutational status is needed for therapeutic decision-making. Most prevalent in colorectal cancer are KRAS exon 2 mutations (40% prevalence); lower prevalence is observed for KRAS exon 3 and 4 mutations (6%) and NRAS exon 2, 3, and 4 mutations (5%). The Idylla™ KRAS Mutation Test on the molecular diagnostics Idylla™ platform is a simple (<2 minutes hands-on time), highly reliable, and rapid (approximately 2 hours turnaround time) in vitro diagnostic sample-to-result solution. This test enables qualitative detection of 21 mutations in codons 12, 13, 59, 61, 117, and 146 of the KRAS oncogene being clinically relevant according to the latest clinical guidelines. Here, the performance of the Idylla™ KRAS Mutation Assay, for Research Use Only, was assessed on archived formalin-fixed paraffin-embedded (FFPE) tissue sections by comparing its results with the results previously obtained by routine reference approaches for KRAS genotyping. In case of discordance, samples were assessed further by additional methods. Among the 374 colorectal cancer FFPE samples tested, the overall concordance between the Idylla™ KRAS Mutation Assay and the confirmed reference routine test results was found to be 98.9%. The Idylla™ KRAS Mutation Assay enabled detection of 5 additional KRAS-mutated samples not detected previously with reference methods. As conclusion the Idylla™ KRAS Mutation Test can be applied as routine tool in any clinical setting, without needing molecular infrastructure or expertise, to guide the personalized treatment of colorectal cancer patients. PMID:27685259

  12. A simplified version of the total Kjeldahl nitrogen method using an ammonia extraction ultrasound-assisted purge-and-trap system and ion chromatography for analyses of geological samples.

    PubMed

    Pontes, Fernanda V M; Carneiro, Manuel C; Vaitsman, Delmo S; da Rocha, Genilda P; da Silva, Lílian I D; Neto, Arnaldo A; Monteiro, Maria Inês C

    2009-01-26

    The total Kjeldahl nitrogen (TKN) method was simplified by using a manifold connected to a purge-and-trap system immersed into an ultrasonic (US) bath for simultaneous ammonia (NH(3)) extraction from many previously digested samples. Then, ammonia was collected in an acidic solution, converted to ammonium (NH(4)(+)), and finally determined by ion chromatography method. Some variables were optimized, such as ultrasonic irradiation power and frequency, ultrasound-assisted NH(3) extraction time, NH(4)(+) mass and sulfuric acid concentration added to the NH(3) collector flask. Recovery tests revealed no changes in the pH values and no conversion of NH(4)(+) into other nitrogen species during the irradiation of NH(4)Cl solutions with 25 or 40 kHz ultrasonic waves for up to 20 min. Sediment and oil free sandstone samples and soil certified reference materials (NCS DC 73319, NCS DC 73321 and NCS DC 73326) with different total nitrogen concentrations were analysed. The proposed method is faster, simpler and more sensitive than the classical Kjeldahl steam distillation method. The time for NH(3) extraction by the US-assisted purge-and-trap system (20 min) was half of that by the Kjeldahl steam distillation (40 min) for 10 previously digested samples. The detection limit was 9 microg g(-1)N, while for the Kjeldahl classical/indophenol method was 58 microg g(-1)N. Precision was always better than 13%. In the proposed method, carcinogenic reagents are not used, contrarily to the indophenol method. Furthermore, the proposed method can be adapted for fixed-NH(4)(+) determination.

  13. Using expired air carbon monoxide to determine smoking status during pregnancy: preliminary identification of an appropriately sensitive and specific cut-point.

    PubMed

    Bailey, Beth A

    2013-10-01

    Measurement of carbon monoxide in expired air samples (ECO) is a non-invasive, cost-effective biochemical marker for smoking. Cut points of 6ppm-10ppm have been established, though appropriate cut-points for pregnant woman have been debated due to metabolic changes. This study assessed whether an ECO cut-point identifying at least 90% of pregnant smokers, and misidentifying fewer than 10% of non-smokers, could be established. Pregnant women (N=167) completed a validated self-report smoking assessment, a urine drug screen for cotinine (UDS), and provided an expired air sample twice during pregnancy. Half of women reported non-smoking status early (51%) and late (53%) in pregnancy, confirmed by UDS. Using a traditional 8ppm+cut-point for the early pregnancy reading, only 1% of non-smokers were incorrectly identified as smokers, but only 56% of all smokers, and 67% who smoked 5+ cigarettes in the previous 24h, were identified. However, at 4ppm+, only 8% of non-smokers were misclassified as smokers, and 90% of all smokers and 96% who smoked 5+ cigarettes in the previous 24h were identified. False positives were explained by heavy second hand smoke exposure and marijuana use. Results were similar for late pregnancy ECO, with ROC analysis revealing an area under the curve of .95 for early pregnancy, and .94 for late pregnancy readings. A lower 4ppm ECO cut-point may be necessary to identify pregnant smokers using expired air samples, and this cut-point appears valid throughout pregnancy. Work is ongoing to validate findings in larger samples, but it appears if an appropriate cut-point is used, ECO is a valid method for determining smoking status in pregnancy. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Evaluation of a cow-side milk progesterone assay and assessment of the positive predictive value of oestrus diagnosis by dairy farmers in New South Wales.

    PubMed

    Ingenhoff, L; Hall, E; House, J K

    2016-12-01

    The three objectives of this study were to determine the positive predictive value (PPV) of oestrus diagnosis (heat detection accuracy) by dairy farmers, calculate the diagnostic sensitivity and specificity of the P4 Rapid milk progesterone assay for detecting a corpus luteum and evaluate the economics of using a cow-side milk progesterone assay designed to aid oestrus diagnosis. Milk samples were collected from 752 cows diagnosed in oestrus by farm personnel on 14 dairy farms. Samples were tested using the P4 Rapid milk progesterone assay to estimate the PPV of oestrus diagnosis at each farm and a crude pooled mean of PPV of oestrus diagnosis across all farms. A further 156 milk samples were collected from cows with luteal tissue status determined by transrectal ultrasound and tested by the P4 Rapid assay to enable calculation of the sensitivity and specificity of the P4 Rapid assay. For pooled farm samples, the PPV was 97.0%, with a range between farms of 88.9-100%. Sensitivity of the P4 Rapid milk progesterone assay for detecting a corpus luteum was 90.1% and specificity was 98.7%. Misclassification of oestrus in cows previously identified as pregnant was the most common cause of false-positive oestrus diagnoses by farm personnel. Routine testing of milk progesterone in all cows diagnosed in oestrus is not economically justified and may even slightly reduce submission rates; conversely, strategic use of cow-side milk progesterone assays can improve herd reproductive performance by facilitating decisions on whether to rebreed cows previously diagnosed as pregnant. © 2016 Australian Veterinary Association.

  15. An analysis of Apollo lunar soil samples 12070,889, 12030,187, and 12070,891: Basaltic diversity at the Apollo 12 landing site and implications for classification of small-sized lunar samples

    NASA Astrophysics Data System (ADS)

    Alexander, Louise; Snape, Joshua F.; Joy, Katherine H.; Downes, Hilary; Crawford, Ian A.

    2016-09-01

    Lunar mare basalts provide insights into the compositional diversity of the Moon's interior. Basalt fragments from the lunar regolith can potentially sample lava flows from regions of the Moon not previously visited, thus, increasing our understanding of lunar geological evolution. As part of a study of basaltic diversity at the Apollo 12 landing site, detailed petrological and geochemical data are provided here for 13 basaltic chips. In addition to bulk chemistry, we have analyzed the major, minor, and trace element chemistry of mineral phases which highlight differences between basalt groups. Where samples contain olivine, the equilibrium parent melt magnesium number (Mg#; atomic Mg/[Mg + Fe]) can be calculated to estimate parent melt composition. Ilmenite and plagioclase chemistry can also determine differences between basalt groups. We conclude that samples of approximately 1-2 mm in size can be categorized provided that appropriate mineral phases (olivine, plagioclase, and ilmenite) are present. Where samples are fine-grained (grain size <0.3 mm), a "paired samples t-test" can provide a statistical comparison between a particular sample and known lunar basalts. Of the fragments analyzed here, three are found to belong to each of the previously identified olivine and ilmenite basalt suites, four to the pigeonite basalt suite, one is an olivine cumulate, and two could not be categorized because of their coarse grain sizes and lack of appropriate mineral phases. Our approach introduces methods that can be used to investigate small sample sizes (i.e., fines) from future sample return missions to investigate lava flow diversity and petrological significance.

  16. A hybrid solution using computational prediction and measured data to accurately determine process corrections with reduced overlay sampling

    NASA Astrophysics Data System (ADS)

    Noyes, Ben F.; Mokaberi, Babak; Mandoy, Ram; Pate, Alex; Huijgen, Ralph; McBurney, Mike; Chen, Owen

    2017-03-01

    Reducing overlay error via an accurate APC feedback system is one of the main challenges in high volume production of the current and future nodes in the semiconductor industry. The overlay feedback system directly affects the number of dies meeting overlay specification and the number of layers requiring dedicated exposure tools through the fabrication flow. Increasing the former number and reducing the latter number is beneficial for the overall efficiency and yield of the fabrication process. An overlay feedback system requires accurate determination of the overlay error, or fingerprint, on exposed wafers in order to determine corrections to be automatically and dynamically applied to the exposure of future wafers. Since current and future nodes require correction per exposure (CPE), the resolution of the overlay fingerprint must be high enough to accommodate CPE in the overlay feedback system, or overlay control module (OCM). Determining a high resolution fingerprint from measured data requires extremely dense overlay sampling that takes a significant amount of measurement time. For static corrections this is acceptable, but in an automated dynamic correction system this method creates extreme bottlenecks for the throughput of said system as new lots have to wait until the previous lot is measured. One solution is using a less dense overlay sampling scheme and employing computationally up-sampled data to a dense fingerprint. That method uses a global fingerprint model over the entire wafer; measured localized overlay errors are therefore not always represented in its up-sampled output. This paper will discuss a hybrid system shown in Fig. 1 that combines a computationally up-sampled fingerprint with the measured data to more accurately capture the actual fingerprint, including local overlay errors. Such a hybrid system is shown to result in reduced modelled residuals while determining the fingerprint, and better on-product overlay performance.

  17. Calorimetric system and method

    DOEpatents

    Gschneidner, Jr., Karl A.; Pecharsky, Vitalij K.; Moorman, Jack O.

    1998-09-15

    Apparatus for measuring heat capacity of a sample where a series of measurements are taken in succession comprises a sample holder in which a sample to be measured is disposed, a temperature sensor and sample heater for providing a heat pulse thermally connected to the sample, and an adiabatic heat shield in which the sample holder is positioned and including an electrical heater. An electrical power supply device provides an electrical power output to the sample heater to generate a heat pulse. The electrical power from a power source to the heat shield heater is adjusted by a control device, if necessary, from one measurement to the next in response to a sample temperature-versus-time change determined before and after a previous heat pulse to provide a subsequent sample temperature-versus-time change that is substantially linear before and after the subsequent heat pulse. A temperature sensor is used and operable over a range of temperatures ranging from approximately 3K to 350K depending upon the refrigerant used. The sample optionally can be subjected to dc magnetic fields such as from 0 to 12 Tesla (0 to 120 kOe).

  18. Determination of benzotriazole corrosion inhibitors from aqueous environmental samples by liquid chromatography-electrospray ionization-tandem mass spectrometry.

    PubMed

    Weiss, Stefan; Reemtsma, Thorsten

    2005-11-15

    The first method for the determination of commonly used corrosion inhibitors in environmental water samples by liquid chromatography-electrospray ionization-tandem mass spectrometry is presented. Benzotriazole (BTri) and the two isomers of tolyltriazole (5- and 4-TTri) are separated in an isocratic run. By gradient elution, BTri, 4-TTri, 5-TTri, and xylyltriazole can be determined simultaneously with three benzothiazoles, but here TTri isomers coelute. The instrumental detection limit of 2 pg allows the determination of the three most important benzotriazoles from municipal wastewater and most surface waters by direct injection into the HPLC system without previous enrichment. When solid-phase extraction is employed with mean recovery rates of 95-113%, the limit of quantification for benzotriazoles range from 10 ng/L in groundwater to 25 ng/L in untreated wastewater. BTri and TTri were determined in municipal wastewater in microgram per liter concentrations. Elimination in wastewater treatment appears to be poor, and BTri and TTri can be followed through a water cycle from treated municipal wastewater through surface water to bank filtrate used for drinking water production. The TTri isomers show markedly different biodegradation behavior with 4-TTri being more stable.

  19. Computerized in vitro test for chemical toxicity based on tetrahymena swimming patterns

    NASA Technical Reports Server (NTRS)

    Noever, David A.; Matsos, Helen C.; Cronise, Raymond J.; Looger, Loren L.; Relwani, Rachna A.; Johnson, Jacqueline U.

    1994-01-01

    An apparatus and method for rapidly determining chemical toxicity was evaluated. The toxicity monitor includes an automated scoring of how motile biological cells (Tetrahymena pyriformis) slow down or otherwise change their swimming patterns in a hostile chemical environment. The device, called the Motility Assay Apparatus (MAA) is tested for 30 second determination of chemical toxicity in 20 aqueous samples containing trace organics and salts. With equal or better detection limits, results compare favorably to in vivo animal tests of eye irritancy, in addition to agreeing for all chemicals with previous manual evaluations of single cell motility.

  20. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; use of a modified ultrasonic nebulizer for the analysis of low ionic-strength water by inductively coupled optical emission spectrometry

    USGS Publications Warehouse

    Harris, Carl M.; Litteral, Charles J.; Damrau, Donna L.

    1997-01-01

    The U.S. Geological Survey National Water Quality Laboratory has developed a method for the determination of dissolved calcium, iron, magnesium, manganese, silica, and sodium using a modified ultrasonic nebulizer sample-introduction system to an inductively coupled plasma-optical emission spectrometer. The nebulizer's spray chamber has been modified to avoid carryover and memory effects common in some conventional ultrasonic designs. The modified ultrasonic nebulizer is equipped with a high-speed rinse cycle to remove previously analyzed samples from the spray chamber without excessive flush times. This new rinse cycle decreases sample washout times by reducing carryover and memory effects from salt or analytes in previously analyzed samples by as much as 45 percent. Plasma instability has been reduced by repositioning the argon carrier gas inlet on the spray chamber and by directly pumping waste from the chamber, instead of from open drain traps, thereby maintaining constant pressure to the plasma. The ultrasonic nebulizer improves signal intensities, which are 8 to 16 times greater than for a conventional cross-flow pneumatic nebulizer, without being sensitive to clogging from salt buildup as in cross-flow nebulizers. Detection limits for the ultrasonic nebulizer are 4 to 18 times less than detection limits achievable using a cross-flow pneumatic nebulizer, with equivalent sample analysis time.

  1. Characterization of structure and thermophysical properties of three ESR slags

    NASA Astrophysics Data System (ADS)

    Plotkowski, A.; deBarbadillo, J.; Krane, Matthew J. M.

    2016-07-01

    The structure and properties of electroslag remelting (ESR) slags were characterized. Slags samples of three compositions were obtained from industrial remelting processes at Special Metals Corporation and from casting in a laboratory vacuum induction melter. The structure of the slag samples was observed using optical and electron microscopy, and phases were identified and their relative amounts quantified using X-ray diffraction. Laser flash thermal diffusivity, density, and differential scanning calorimetry measurements for specific heat were performed to determine the bulk thermal conductivity of the samples. Sample porosity was measured as a function of depth using a serial sectioning technique, and a onedimensional computational model was developed to estimate the thermal conductivity of the fully dense slags. These results are discussed in context with previous studies, and opportunities for future research are identified. AFRL Case Number: 88ABW-2015-1871.

  2. Unified Model for the Overall Efficiency of Inlets Sampling from Horizontal Aerosol Flows

    NASA Astrophysics Data System (ADS)

    Hangal, Sunil Pralhad

    When sampling aerosols from ambient or industrial air environments, the sampled aerosol must be representative of the aerosol in the free stream. The changes that occur during sampling must be assessed quantitatively so that sampling errors can be compensated for. In this study, unified models have been developed for the overall efficiency of tubular sharp-edged inlets sampling from horizontal aerosol flows oriented at 0 to 90^circ relative to the wind direction in the vertical (pitch) and horizontal plane(yaw). In the unified model, based on experimental data, the aspiration efficiency is represented by a single equation with different inertial parameters at 0 to 60^ circ and 45 to 90^circ . Tnt transmission efficiency is separated into two components: one due to gravitational settling in the boundary layer and the other due to impaction. The gravitational settling component is determined by extending a previously developed isoaxial sampling model to nonisoaxial sampling. The impaction component is determined by a new model that quantifies the particle losses caused by wall impaction. The model also quantifies the additional particle losses resulting from turbulent motion in the vena contracta which is formed in the inlet when the inlet velocity is higher than the wind velocity. When sampling aerosols in ambient or industrial environments with an inlet, small changes in wind direction or physical constraints in positioning the inlet in the system necessitates the assessment of sampling efficiency in both the vertical and horizontal plane. The overall sampling efficiency of tubular inlets has been experimentally investigated in yaw and pitch orientations at 0 to 20 ^circ from horizontal aerosol flows using a wind tunnel facility. The model for overall sampling efficiency has been extended to include both yaw and pitch sampling based on the new data. In this model, the difference between yaw and pitch is expressed by the effect of gravity on the impaction process inside the inlet described by a newly developed gravity effect angle. At yaw, the gravity effect angle on the wall impaction process does not change with sampling angle. At pitch, the gravity effect on the impaction process results in particle loss increase for upward and decrease for downward sampling. Using the unified model, graphical representations have been developed for sampling at small angles. These can be used in the field to determine the overall sampling efficiency of inlets at several operating conditions and the operating conditions that result in an acceptable sampling error. Pitch and diameter factors have been introduced for relating the efficiency values over a wide range of conditions to those of a reference condition. The pitch factor determines the overall sampling efficiency at pitch from yaw values, and the diameter factor determines the overall sampling efficiency at different inlet diameters.

  3. Binary Colloidal Alloy Test-3 and 4: Critical Point

    NASA Technical Reports Server (NTRS)

    Weitz, David A.; Lu, Peter J.

    2007-01-01

    Binary Colloidal Alloy Test - 3 and 4: Critical Point (BCAT-3-4-CP) will determine phase separation rates and add needed points to the phase diagram of a model critical fluid system. Crewmembers photograph samples of polymer and colloidal particles (tiny nanoscale spheres suspended in liquid) that model liquid/gas phase changes. Results will help scientists develop fundamental physics concepts previously cloaked by the effects of gravity.

  4. Soil carbon and nitrogen changes in forests of Walker Branch Watershed, 1972 to 2004

    Treesearch

    D.W. Johnson; D.E. Todd; C.E. Trettin; J.S. Sedlinger

    2007-01-01

    Changes in soil C and N concentrations and contents in four samplings during a 32-yr period on Walker Branch watershed in Tennessee were determined and compared with previously measured C and N fluxes and with changes in ecosystem C and N pools during this period. Soils showed significant increases in C and N concentrations in surface horizons from 1972 to 2004, and...

  5. Cell Therapy to Obtain Spinal Fusion

    DTIC Science & Technology

    2007-03-01

    2006. 38. Backesjo, C.M., Li, Y., Lindgren, U., and Haldosen, L.A. Activation of Sirt1 decreases adipocyte formation during osteoblast...However, in the whole blood samples with the same number of white cells, BMP2 activity was equal to the control suggesting that either the vector was... supplemented with 2% FBS, with antibiotic-antimycotic. Since we previously determined that the critical factor for inducing bone formation is the level

  6. Effects of blue light phototherapy on DNA integrity in preterm newborns.

    PubMed

    Gómez-Meda, Belinda C; Barros-Hernández, Angélica; Guzmán-Bárcenas, José; Lemus-Varela, María de Lourdes; Zamora-Perez, Ana L; Torres-Mendoza, Blanca M; Gallegos-Arreola, Martha P; Armendáriz-Borunda, Juan; Zúñiga-González, Guillermo M

    2014-12-01

    In previous studies, exposure to phototherapy, but not oxygen therapy, resulted in damage to genetic material in newborns. The objective of this study was to determine whether micronucleated erythrocytes (MNE) increased in preterm newborns (PNBs) who were exposed to blue light phototherapy lamps. MNE of mature organisms are rapidly eliminated by the spleen, and the presence of MNE has been related to immaturity in some species. Furthermore, PNBs present spontaneous MNE. Blood samples were taken from 17 PNBs at birth to establish baseline frequencies (0 h). After beginning blue light phototherapy, blood samples were obtained from 11 of these PNBs at 24-h intervals for 96 h, after the baseline sample. MNE and micronucleated polychromatic erythrocytes (MNPCE) were counted. The basal values of MNE and MNPCE from 17 PNBs were 0.62 ± 0.48 and 1.52 ± 1.28 (‰), respectively, and no increase in MNE or MNPCE was observed in the serial samples of 11 PNBs exposed to blue light and oxygen therapies, though previous studies reported increases using other types of lamps. In conclusion, under the conditions described no increase in the number of MNE or MNPCE was observed in the peripheral blood of PNBs exposed to blue light phototherapy. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Pregnancy rates after artificial insemination with cooled stallion spermatozoa either with or without single layer centrifugation.

    PubMed

    Morrell, J M; Richter, J; Martinsson, G; Stuhtmann, G; Hoogewijs, M; Roels, K; Dalin, A-M

    2014-11-01

    A successful outcome after artificial insemination with cooled semen is dependent on many factors, the sperm quality of the ejaculate being one. Previous studies have shown that spermatozoa with good motility, normal morphology, and good chromatin integrity can be selected by means of colloid centrifugation, particularly single layer centrifugation (SLC) using species-specific colloids. The purpose of the present study was to conduct an insemination trial with spermatozoa from "normal" ejaculates, i.e., from stallions with no known fertility problem, to determine whether the improvements in sperm quality seen in SLC-selected sperm samples compared with uncentrifuged controls in laboratory tests are reflected in an increased pregnancy rate after artificial insemination. In a multicentre study, SLC-selected sperm samples and uncentrifuged controls from eight stallions were inseminated into approximately 10 mares per treatment per stallion. Ultrasound examination was carried out approximately 16 days after insemination to detect an embryonic vesicle. The pregnancy rates per cycle were 45% for controls and 69% for SLC-selected sperm samples, which is statistically significant (P < 0.0018). Thus, the improvement in sperm quality reported previously for SLC-selected sperm samples is associated with an increase in pregnancy rate, even for ejaculates from stallions with no known fertility problem. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Can People Guess What Happened to Others from Their Reactions?

    PubMed Central

    Pillai, Dhanya; Sheppard, Elizabeth; Mitchell, Peter

    2012-01-01

    Are we able to infer what happened to a person from a brief sample of his/her behaviour? It has been proposed that mentalising skills can be used to retrodict as well as predict behaviour, that is, to determine what mental states of a target have already occurred. The current study aimed to develop a paradigm to explore these processes, which takes into account the intricacies of real-life situations in which reasoning about mental states, as embodied in behaviour, may be utilised. A novel task was devised which involved observing subtle and naturalistic reactions of others in order to determine the event that had previously taken place. Thirty-five participants viewed videos of real individuals reacting to the researcher behaving in one of four possible ways, and were asked to judge which of the four ‘scenarios’ they thought the individual was responding to. Their eye movements were recorded to establish the visual strategies used. Participants were able to deduce successfully from a small sample of behaviour which scenario had previously occurred. Surprisingly, looking at the eye region was associated with poorer identification of the scenarios, and eye movement strategy varied depending on the event experienced by the person in the video. This suggests people flexibly deploy their attention using a retrodictive mindreading process to infer events. PMID:23226227

  9. A Method for Continuous (239)Pu Determinations in Arctic and Antarctic Ice Cores.

    PubMed

    Arienzo, M M; McConnell, J R; Chellman, N; Criscitiello, A S; Curran, M; Fritzsche, D; Kipfstuhl, S; Mulvaney, R; Nolan, M; Opel, T; Sigl, M; Steffensen, J P

    2016-07-05

    Atmospheric nuclear weapons testing (NWT) resulted in the injection of plutonium (Pu) into the atmosphere and subsequent global deposition. We present a new method for continuous semiquantitative measurement of (239)Pu in ice cores, which was used to develop annual records of fallout from NWT in ten ice cores from Greenland and Antarctica. The (239)Pu was measured directly using an inductively coupled plasma-sector field mass spectrometer, thereby reducing analysis time and increasing depth-resolution with respect to previous methods. To validate this method, we compared our one year averaged results to published (239)Pu records and other records of NWT. The (239)Pu profiles from the Arctic ice cores reflected global trends in NWT and were in agreement with discrete Pu profiles from lower latitude ice cores. The (239)Pu measurements in the Antarctic ice cores tracked low latitude NWT, consistent with previously published discrete records from Antarctica. Advantages of the continuous (239)Pu measurement method are (1) reduced sample preparation and analysis time; (2) no requirement for additional ice samples for NWT fallout determinations; (3) measurements are exactly coregistered with all other chemical, elemental, isotopic, and gas measurements from the continuous analytical system; and (4) the long half-life means the (239)Pu record is stable through time.

  10. The γ-ray angular distribution in fast neutron inelastic scattering from iron

    NASA Astrophysics Data System (ADS)

    Beyer, Roland; Dietz, Mirco; Bemmerer, Daniel; Junghans, Arnd R.; Kögler, Toni; Massarczyk, Ralph; Müller, Stefan; Schmidt, Konrad; Schwengner, Ronald; Szücs, Tamás; Takács, Marcell P.; Wagner, Andreas

    2018-04-01

    The angular distribution of γ-rays emitted after inelastic scattering of fast neutrons from iron was determined at the n ELBE neutron time-of-flight facility. An iron sample of natural isotopic composition was irradiated by a continuous photo-neutron spectrum in the energy range from about 0.1 up to 10 MeV. The de-excitation γ-rays of the four lowest excited states of 56Fe and the first excited state of 54Fe were detected using a setup of five high-purity germanium (HPGe) detectors and five LaBr3 scintillation detectors positioned around the sample at 30°, 55°, 90°, 125° and 150° with respect to the incoming neutron beam. The resulting angular distributions were fitted by Legendre polynomials up to 4th order and the angular distribution coefficients a2 and a4 were extracted. The angular distribution coefficients of three transitions in 56Fe are reported here for the first time. The results are applied to a previous measurement of the inelastic scattering cross section determined using a single HPGe detector positioned at 125°. Using the updated γ-ray angular distribution, the previous cross section results are in good agreement with reference data.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scheele, R.D.

    In 1995, available subsegment samples of wastes taken from the Hanford Site underground radioactive waste storage tanks 241-C-112 (C-112) and 241-C-109 (C-109) were reanalyzed to determine the nickel concentrations in the samples and to determine whether the use of a nickel crucible in the analytical sample preparation biased the reported nickel concentrations reported by Simpson and coworkers and in the original report that this report supplements. The reanalysis strategy to determine nickel was to use a sodium peroxide flux in a zirconium crucible instead of the previously used potassium hydroxide flux in a nickel crucible. This supplemental report provides themore » results of the reanalyses and updates tables from the original report which reflect the new nickel analyses. Nickel is important with respect to management of the potentially reactive ferrocyanide wastes as it is one of the key defining characteristics of the solids that resulted from scavenging radiocesium using ferrocyanides. In Hanford Site wastes, few other processes introduced nickel into the wastes other than radiocobalt scavenging, which was often coupled with the ferrocyanide-scavenging process. Thus the presence of nickel in a waste provides strong evidence that the original waste was or contained ferrocyanide waste at one time. Given the potential import of nickel as a defining characteristic and marker for ferrocyanide wastes, the Pacific Northwest Laboratory`s (PNL) Analytical Chemistry Laboratory (ACL) reanalyzed available samples from tanks C-112 and C-109 using inductively coupled argon plasma/atomic emission spectrometry (ICP/AES) and an alternative sample preparation method which precluded contamination of the analytical samples with nickel.« less

  12. Attitudes and factors affecting acceptability of self-administered cervicovaginal sampling for human papillomavirus (HPV) genotyping as an alternative to Pap testing among multiethnic Malaysian women.

    PubMed

    Ma'som, Mahirah; Bhoo-Pathy, Nirmala; Nasir, Nazrila Hairizan; Bellinson, Jerome; Subramaniam, Shridevi; Ma, Yuntong; Yap, Siew-Hwei; Goh, Pik-Pin; Gravitt, Patti; Woo, Yin Ling

    2016-08-04

    The objective of this study was to determine the attitudes and acceptability of self-administered cervicovaginal sampling compared with conventional physician-acquired Papanicolaou (Pap) smear among multiethnic Malaysian women. A cross-sectional study was carried out via interviewer-administered surveys from August 2013 through August 2015 at five government-run, urban health clinics in the state of Selangor. Subjects were participants from an ongoing community-based human papillomavirus (HPV) prevalence study who answered a standard questionnaire before and after self-sampling. The cervicovaginal self-sampling for HPV genotyping was performed using a simple brush ('Just for Me'; Preventive Oncology International, Hong Kong). Detailed data on sociodemographics, previous Pap smear experience, and attitudes towards self-administered cervicovaginal sampling were collected and analysed. Acceptability was inferred using a five-item Likert scale that included six different subjective descriptives: experience, difficulty, convenience, embarrassment, discomfort or pain, and confidence in collecting one's own sample. Of the 839 participants, 47.9% were Malays, followed by 30.8% Indians, 18.8% Chinese and 2.5% from other ethnicities. The median age of the participants was 38 years (IQR 30-48). Some 68.2% of participants indicated a preference for self-sampling over the Pap test, with 95% indicating willingness to follow-up a positive result at the hospital. Age, ethnicity and previous Pap test experience were significant independent factors associated with preference for self-sampling. The older the individual, the less likely they were to prefer self-sampling (adjusted OR 0.94, 95% CI 0.90 to 0.98). The Chinese were less likely to prefer self-sampling (72.6%) than the Malays (85.1%) (adjusted OR 0.57, 95% CI 0.33 to 0.98, p=0.004). Participants who had never undergone a Pap smear were also more likely to prefer self-sampling (88.5%) than women who had undergone a previous Pap (80.9%) (adjusted OR 0.06, 95% CI 0.35 to 0.87). Overall, urban Malaysian women from multiethnic backgrounds found self-sampling to be an acceptable alternative to Pap smear. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Distribution in Rats Internal Organs of Intraperitoneally Given 125I-Labeled Heptapeptide [2-8]-Leucopyrokinin ([2-8]-LPK), a Truncated Analog of Insect Neuropeptide Leucopyrokinin.

    PubMed

    Ryszka, Florian; Dolińska, Barbara; Suszka-Świtek, Aleksandra; Rykaczewska-Czerwińska, Monika; Konopińska, Danuta; Kuczer, Mariola; Plech, Andrzej

    2015-01-01

    It was previously found that synthetic, insect-derived octapeptide leucopyrokinin (LPK) applied directly into the lateral brain ventricle induced a significant antinociceptive effect in rats. Its synthetic truncated analog heptapeptide [2-8]-leucopyrokinin displayed a stronger antinociceptive effect in comparison to native LPK. Moreover it was previously found a high accumulation of these both 125I-labeled peptides in adrenals, as well as in hypothalamus and in hippocampus of rats brain. The aim of the present study was to assess the distribution of 125I-labeled [2-8]-leucopyrokinin in rats' internal organs an in several parts of the brain after peripheral - intraperitoneal (i.p.) administration. The study was performed on male Wistar rats. A synthetic [2-8]-leucopyrokinin ([2-8]-LPK) was iodinated with Na125I. On the day of experiment a solution of 125I-[2-8]-LPK was i.p. injected and the next after 1 and 24 h animals were sacrificed by decapitation. Radioactivity levels in samples of parts of the brain and of internal organs were determined by counter Gamma Auto Count. A uniform, low accumulation 125I-[2-8]-LPK was found in evaluated samples of the brain and in internal organs. The results of the present study indicate a weak penetration into the brain and internal organs of intraperitoneally applied 125I-[2-8]-LPK in rats and correspond with previously determined weak biological effects of i.p. injected LPK and [2-8]-LPK.

  14. Evaluation of the Abbott RealTime HCV genotype II plus RUO (PLUS) assay with reference to core and NS5B sequencing.

    PubMed

    Mallory, Melanie A; Lucic, Danijela; Ebbert, Mark T W; Cloherty, Gavin A; Toolsie, Dan; Hillyard, David R

    2017-05-01

    HCV genotyping remains a critical tool for guiding initiation of therapy and selecting the most appropriate treatment regimen. Current commercial genotyping assays may have difficulty identifying 1a, 1b and genotype 6. To evaluate the concordance for identifying 1a, 1b, and genotype 6 between two methods: the PLUS assay and core/NS5B sequencing. This study included 236 plasma and serum samples previously genotyped by core/NS5B sequencing. Of these, 25 samples were also previously tested by the Abbott RealTime HCV GT II Research Use Only (RUO) assay and yielded ambiguous results. The remaining 211 samples were routine genotype 1 (n=169) and genotype 6 (n=42). Genotypes obtained from sequence data were determined using a laboratory-developed HCV sequence analysis tool and the NCBI non-redundant database. Agreement between the PLUS assay and core/NS5B sequencing for genotype 1 samples was 95.8% (162/169), with 96% (127/132) and 95% (35/37) agreement for 1a and 1b samples respectively. PLUS results agreed with core/NS5B sequencing for 83% (35/42) of unselected genotype 6 samples, with the remaining seven "not detected" by the PLUS assay. Among the 25 samples with ambiguous GT II results, 15 were concordant by PLUS and core/NS5B sequencing, nine were not detected by PLUS, and one sample had an internal control failure. The PLUS assay is an automated method that identifies 1a, 1b and genotype 6 with good agreement with gold-standard core/NS5B sequencing and can aid in the resolution of certain genotype samples with ambiguous GT II results. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Spectroscopic determination of fundamental parameters of small angular diameter galactic open clusters

    NASA Astrophysics Data System (ADS)

    Ahumada, A. V.; Claria, J. J.; Bica, E.; Parisi, M. C.; Torres, M. C.; Pavani, D. B.

    We present integrated spectra obtained at CASLEO (Argentina) for 9 galactic open clusters of small angular diameter. Two of them (BH 55 and Rup 159) have not been the target of previous research. The flux-calibrated spectra cover the spectral range approx. 3600-6900 A. Using the equivalent widths (EWs) of the Balmer lines and comparing the cluster spectra with template spectra, we determined E(B-V) colour excesses and ages for the present cluster sample. The parameters obtained for 6 of the clusters show good agreement with previous determinations based mainly on photometric methods. This is not the case, however, for BH 90, a scarcely reddened cluster, for which Moffat and Vogt (1975, Astron. and Astroph. SS, 20, 125) derived E(B-V) = 0.51. We explain and justify the strong discrepancy found for this object. According to the present analysis, 3 clusters are very young (Bo 14, Tr 15 and Tr 27), 2 are moderately young (NGC 6268 and BH 205), 3 are Hyades-like clusters (Rup 164, BH 90 and BH 55) and only one is an intermediate-age cluster (Rup 159).

  16. Pulverized Tejon Lookout Granite: Attempts at Placing Constraints on the Processes

    NASA Astrophysics Data System (ADS)

    Sisk, M.; Dor, O.; Rockwell, T.; Girty, G.; Ben-Zion, Y.

    2007-12-01

    We have described and analyzed pulverized Tejon Lookout granite recovered from several transects of the western segment of the Garlock fault on Tejon Ranch in southern California. Observations and data collected at this location are compared to a sampled transect of the San Andreas fault at Tejon Pass previously studied by Wilson et al. (2005), also exposing the Tejon Lookout granite. The purpose of this study is to characterize the physical and chemical properties of the pervasively pulverized leucocratic rocks at multiple locations and to hopefully place constraints on the processes producing them. To accomplish this we performed particle size analysis with the use of both laser particle analyzer and pipette methodology; major and trace chemistry analyses determined by XRF; clay mineralogy determined by XRD; and we evaluated fabric and texture through the study of thin sections. Recovered samples met the field criteria of pulverization developed by Dor et al., 2006 - that is, the individual 1-2 mm-sized crystals can be recognized in the field but the granite (including quartz and feldspar) can be mashed with ones fingers and exhibits the texture of toothpaste. All samples were analyzed on a Horiba LA930 Laser Particle Analyzer in an attempt to reproduce the earlier results of Wilson et al. (2005) with similar methodology. We also utilized the classic pipette methodology to ensure complete discrimination of particle sizes. Our PSD analysis shows that the dominant particle size falls in the 31-125 micron range, much coarser than previously reported by Wilson et al. (2005), with >90% of the total sample falling in the >31 micron size range. We can reproduce the previously documented results by allowing the samples to circulate for long periods of time at slow circulation speeds in the laser particle size analyzer, during which time the coarse fraction settles out, thereby leaving only the fine fraction for detection. However, subsequent increase in the circulation speed leads to a complete recovery of the original PSD. Our XRF and XRD analyses provide evidence of the lack of major weathering products and their inability to skew the PSD results in a significant way. Dor et al. (2007) and Stillings et al. (2007) document evidence that support theoretical predictions and previous inferences of pulverization occurring in the upper few kilometers, especially along faults of the southern San Andreas system. Geophysical observations of Lewis et al. (2005, 2007) provide evidence that low velocity fault- parallel layers, which are likely made of pulverized or highly damaged material, are dominant in the upper few kilometers of the crust. Their asymmetric position with respect to the slipping zone, in agreement with asymmetric patterns of small scale mapped rock damage (Dor et al., 2006), suggest that pulverized rocks are likely the product of a preferred rupture direction during dynamic slip. Our results combined with the above mentioned works imply that pulverized fault zone rocks at multiple locations are much less damaged than suggested in previous studies.

  17. Determination of strontium-90 in milk samples using a controlled precipitation clean-up step prior to ion-chromatography.

    PubMed

    Cobb, J; Warwick, P; Carpenter, R C; Morrison, R T

    1995-12-01

    Strontium-90 may be determined by beta-counting its yttrium-90 daughter following separation by ion-chromatography, using a three column system comprising a chelating concentrator column, a cation-exchange column and an anion-exchange separator column. The column system has previously been applied to the determination of strontium-90 in water and urine samples. The applicability of the system to the analysis of milk is hampered by the large concentrations of calcium present, which significantly reduces the extraction of yttrium-90 by the concentrator column. A maximum of approximately 200 mg of calcium can be present for the successful extraction of yttrium-90, which greatly limits the quantity of milk that can be analysed. The quantity of milk analysed can be increased by the inclusion of a controlled precipitation step prior to the ion-chromatographic separation. The precipitation is carried out on acid digested milk samples by the addition of ammonia solution until the addition of one drop causes a reduction in pH resulting in the precipitation of calcium hydrogenphosphate. Under these conditions, approximately 20% of the calcium present in the original milk sample is precipitated, yttrium-90 is precipitated whereas strontium-90 is not precipitated. Dissolution of the precipitate, followed by separation of yttrium-90 using the ion-chromatography system facilitates the analysis of a litre of milk with recoveries of greater than 80%.

  18. Sleepiness and Motor Vehicle Crashes in a Representative Sample of Portuguese Drivers: The Importance of Epidemiological Representative Surveys.

    PubMed

    Gonçalves, M; Peralta, A R; Monteiro Ferreira, J; Guilleminault, Christian

    2015-01-01

    Sleepiness is considered to be a leading cause of crashes. Despite the huge amount of information collected in questionnaire studies, only some are based on representative samples of the population. Specifics of the populations studied hinder the generalization of these previous findings. For the Portuguese population, data from sleep-related car crashes/near misses and sleepiness while driving are missing. The objective of this study is to determine the prevalence of near-miss and nonfatal motor vehicle crashes related to sleepiness in a representative sample of Portuguese drivers. Structured phone interviews regarding sleepiness and sleep-related crashes and near misses, driving habits, demographic data, and sleep quality were conducted using the Pittsburgh Sleep Quality Index and sleep apnea risk using the Berlin questionnaire. A multivariate regression analysis was used to determine the associations with sleepy driving (feeling sleepy or falling asleep while driving) and sleep-related near misses and crashes. Nine hundred subjects, representing the Portuguese population of drivers, were included; 3.1% acknowledged falling asleep while driving during the previous year and 0.67% recalled sleepiness-related crashes. Higher education, driving more than 15,000 km/year, driving more frequently between 12:00 a.m. and 6 a.m., fewer years of having a driver's license, less total sleep time per night, and higher scores on the Epworth Sleepiness Scale (ESS) were all independently associated with sleepy driving. Sleepiness-related crashes and near misses were associated only with falling asleep at the wheel in the previous year. Sleep-related crashes occurred more frequently in drivers who had also had sleep-related near misses. Portugal has lower self-reported sleepiness at the wheel and sleep-related near misses than most other countries where epidemiological data are available. Different population characteristics and cultural, social, and road safety specificities may be involved in these discrepancies. Despite this, Portuguese drivers report sleep-related crashes in frequencies similar to those of drivers in other countries.

  19. Spatial and Temporal Water Quality Dynamics in the Lake Maumelle Reservoir (Arkansas): Geochemical and Planktonic Variance in a Drinking Water Source

    NASA Astrophysics Data System (ADS)

    Carey, M. D.; Ruhl, L. S.

    2017-12-01

    The Lake Maumelle reservoir is Central Arkansas's main water supply. Maintaining a high standard of water quality is important to the over 400,000 residents of this area whom rely on this mesotrophic waterbody for drinking water. Lake Maumelle is also a scenic attraction for recreational boating and fishing. Past research has focused primarily on watershed management with land use/land cover modeling and quarterly water sampling of the 13.91mi2 reservoir. The surrounding land within the watershed is predominately densely forested, with timber farms and the Ouachita National Forest. This project identifies water quality changes spatially and temporally, which have not been as frequently observed, over a 6-month timespan. Water samples were collected vertically throughout the water column and horizontally throughout the lake following reservoir zonation. Parameters collected vertically for water quality profiles are temperature, dissolved oxygen, electrical conductivity, salinity, and pH. Soft sediment samples were collected and pore water was extracted by centrifuge. Cation and anion concentrations in the water samples were determined using ion chromatography, and trace element concentrations were determined using ICPMS. Planktonic abundances were determined using an inverted microscope and a 5ml counting chamber. Trace element, cation, and anion concentrations have been compared with planktonic abundance and location to determine microorganismal response to geochemical variance. During June 2017 sampling, parameters varied throughout the water column (temperature decreased 4 degrees Celsius and dissolved oxygen decreased from 98% to 30% from surface to bottom depths), revealing that the reservoir was becoming stratified. Collected plankton samples revealed the presence of copepod, daphnia, and dinoflagellate algae. Utricularia gibba was present in the littoral zone. Low electrical conductivity readings and high water clarity are consistent with the lake's mesotrophic state index classification. The results will be compared to previous sampling events, used to calculate enrichment factors of geochemical constituents, and used to create a geochemical and planktonic map of the lake through time.

  20. Prevalence of urinary tract infection in acutely unwell children in general practice: a prospective study with systematic urine sampling.

    PubMed

    O'Brien, Kathryn; Edwards, Adrian; Hood, Kerenza; Butler, Christopher C

    2013-02-01

    Urinary tract infection (UTI) in children may be associated with long-term complications that could be prevented by prompt treatment. To determine the prevalence of UTI in acutely ill children ≤ 5 years presenting in general practice and to explore patterns of presenting symptoms and urine sampling strategies. Prospective observational study with systematic urine sampling, in general practices in Wales, UK. In total, 1003 children were recruited from 13 general practices between March 2008 and July 2010. The prevalence of UTI was determined and multivariable analysis performed to determine the probability of UTI. Out of 597 (60.0%) children who provided urine samples within 2 days, the prevalence of UTI was 5.9% (95% confidence interval [CI] = 4.3% to 8.0%) overall, 7.3% in those < 3 years and 3.2% in 3-5 year olds. Neither a history of fever nor the absence of an alternative source of infection was associated with UTI (P = 0.64; P = 0.69, respectively). The probability of UTI in children aged ≥3 years without increased urinary frequency or dysuria was 2%. The probability of UTI was ≥5% in all other groups. Urine sampling based purely on GP suspicion would have missed 80% of UTIs, while a sampling strategy based on current guidelines would have missed 50%. Approximately 6% of acutely unwell children presenting to UK general practice met the criteria for a laboratory diagnosis of UTI. This higher than previously recognised prior probability of UTI warrants raised awareness of the condition and suggests clinicians should lower their threshold for urine sampling in young children. The absence of fever or presence of an alternative source of infection, as emphasised in current guidelines, may not rule out UTI in young children with adequate certainty.

  1. Does intrinsic motivation strengthen physical activity habit? Modeling relationships between self-determination, past behaviour, and habit strength.

    PubMed

    Gardner, Benjamin; Lally, Phillippa

    2013-10-01

    Habit formation is thought to aid maintenance of physical activity, but little research is available into determinants of habit strength aside from repeated performance. Previous work has shown that intrinsically motivated physical activity, underpinned by inherent satisfaction derived from activity, is more likely to be sustained. We explored whether this might reflect a tendency for self-determined activity to become more strongly habitual. A sample of 192 adults aged 18-30 completed measures of motivational regulation, intention, behaviour, and habit strength. Results showed that self-determined regulation interacted with past behaviour in predicting habit strength: prior action was more predictive of habit strength among more autonomously motivated participants. There was an unexpected direct effect of self-determined regulation on habit strength, independently of past behaviour. Findings offer possible directions for future habit formation work.

  2. nextPARS: parallel probing of RNA structures in Illumina

    PubMed Central

    Saus, Ester; Willis, Jesse R.; Pryszcz, Leszek P.; Hafez, Ahmed; Llorens, Carlos; Himmelbauer, Heinz

    2018-01-01

    RNA molecules play important roles in virtually every cellular process. These functions are often mediated through the adoption of specific structures that enable RNAs to interact with other molecules. Thus, determining the secondary structures of RNAs is central to understanding their function and evolution. In recent years several sequencing-based approaches have been developed that allow probing structural features of thousands of RNA molecules present in a sample. Here, we describe nextPARS, a novel Illumina-based implementation of in vitro parallel probing of RNA structures. Our approach achieves comparable accuracy to previous implementations, while enabling higher throughput and sample multiplexing. PMID:29358234

  3. Ramp compression of magnesium oxide to 234 GPa

    DOE PAGES

    Wang, Jue; Smith, R. F.; Coppari, F.; ...

    2014-05-07

    Single-crystal magnesium oxide (MgO) samples were ramp compressed to above 200 GPa pressure at the Omega laser facility. Multi-stepped MgO targets were prepared using lithography and wet etching techniques. Free surface velocities of ramp-compressed MgO were measured with a VISAR. The sound velocity and stress-density response were determined using an iterative Lagrangian analysis. The measured equation of state is consistent with expectations from previous shock and static data as well as with a recent X-ray diffraction measurement under ramp loading. The peak elastic stresses observed in our samples had amplitudes of 3-5.5 GPa, decreasing with propagation distance.

  4. Micro-crystallography comes of age

    PubMed Central

    Smith, Janet L.; Fischetti, Robert F.; Yamamoto, Masaki

    2012-01-01

    The latest revolution in macromolecular crystallography was incited by the development of dedicated, user friendly, micro-crystallography beamlines. Brilliant X-ray beams of diameter 20 microns or less, now available at most synchrotron sources, enable structure determination from samples that previously were inaccessible. Relative to traditional crystallography, crystals with one or more small dimensions have diffraction patterns with vastly improved signal-to-noise when recorded with an appropriately matched beam size. Structures can be solved from isolated, well diffracting regions within inhomogeneous samples. This review summarizes the technological requirements and approaches to producing micro-beams and how they continue to change the practice of crystallography. PMID:23021872

  5. Multidimensional Effects on Ignition, Transition, and Flame Spread in Microgravity

    NASA Technical Reports Server (NTRS)

    Kashiwagi, T.; Mell, W. E.; Nakamura, Y.; Olson, S. L.; Baum, H. R.; McGrattan, K. B.

    2001-01-01

    Localized ignition is initiated by an external radiant source at the middle of a thermally thin sample under external slow flow, simulating fire initiation in a spacecraft with a slow ventilation flow. Two ignition configurations are simulated, one across the sample surface creating a line shaped flame front (two-dimensional, 2-D, configuration) and the other a small circular ignition (three-dimensional, 3-D, configuration). Ignition, subsequent transition to simultaneously upstream and downstream flame spread, and flame growth behavior are studied experimentally and theoretically. Details of our theoretical models and numerical techniques can be found in previous publications. The effects of the sample width on the transition and subsequent flame spread, and flame spread along open edges of a thermally thin paper sample are determined. Experimental observations of flame spread phenomena were conducted in the 10 s drop tower and also on the space shuttle STS-75 flight to determine the effects of oxygen concentration and external flow velocity on flame spread rate and flame growth pattern. Finally, effects of confinement in a small test chamber on the transition and subsequent flame spread are examined. The results of these studies are briefly reported.

  6. Sediment quality assessment studies of Tampa bay, Florida

    USGS Publications Warehouse

    Carr, Scott R.; Chapman, Duane C.; Long, Edward R.; Windom, Herbert L.; Thursby, Glen; Sloane, Gail M.; Wolfe, Douglas A.

    1996-01-01

    A survey of the toxicity of sediments throughout the Tampa Bay estuary was performed as part of the National Oceanic and Atmospheric Administration's National Status and Trends Program. The objectives of the survey were to determine the spatial extent and severity of toxicity and to identify relationships between chemical contamination and toxicity. Three independent toxicity tests were performed: a 10-d amphipod survival test of the whole sediments with Ampelisca abdita, a sea urchin fertilization test of sediment pore water with Arbacia punctulata, and a 5-min Microtox® bioluminescence test with solvent extracts of the sediments. Seventy-three percent of the 165 undiluted sediment pore-water samples were significantly toxic relative to reference samples with the sea urchin fertilization test. In contrast, only 2% of the 165 samples were significantly toxic in the amphipod tests. The causes of toxicity were not determined. However, concentrations of numerous trace metals, pesticides, polychlorinated biphenyl (PCB) congeners, polycyclic aromatic hydrocarbons (PAHs), and ammonia were highly correlated with pore-water toxicity. Concentrations of many substances, especially total dichlorodiphenyltrichloroethanes (DDTs), endrin, total PCBs, certain PAHs, lead, and zinc, occurred at concentrations in the toxic samples that equaled or exceeded concentrations that have been previously associated with sediment toxicity.

  7. X-Ray Morphological Analysis of the Planck ESZ Clusters

    NASA Astrophysics Data System (ADS)

    Lovisari, Lorenzo; Forman, William R.; Jones, Christine; Ettori, Stefano; Andrade-Santos, Felipe; Arnaud, Monique; Démoclès, Jessica; Pratt, Gabriel W.; Randall, Scott; Kraft, Ralph

    2017-09-01

    X-ray observations show that galaxy clusters have a very large range of morphologies. The most disturbed systems, which are good to study how clusters form and grow and to test physical models, may potentially complicate cosmological studies because the cluster mass determination becomes more challenging. Thus, we need to understand the cluster properties of our samples to reduce possible biases. This is complicated by the fact that different experiments may detect different cluster populations. For example, Sunyaev-Zeldovich (SZ) selected cluster samples have been found to include a greater fraction of disturbed systems than X-ray selected samples. In this paper we determine eight morphological parameters for the Planck Early Sunyaev-Zeldovich (ESZ) objects observed with XMM-Newton. We found that two parameters, concentration and centroid shift, are the best to distinguish between relaxed and disturbed systems. For each parameter we provide the values that allow selecting the most relaxed or most disturbed objects from a sample. We found that there is no mass dependence on the cluster dynamical state. By comparing our results with what was obtained with REXCESS clusters, we also confirm that the ESZ clusters indeed tend to be more disturbed, as found by previous studies.

  8. X-Ray Morphological Analysis of the Planck ESZ Clusters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lovisari, Lorenzo; Forman, William R.; Jones, Christine

    2017-09-01

    X-ray observations show that galaxy clusters have a very large range of morphologies. The most disturbed systems, which are good to study how clusters form and grow and to test physical models, may potentially complicate cosmological studies because the cluster mass determination becomes more challenging. Thus, we need to understand the cluster properties of our samples to reduce possible biases. This is complicated by the fact that different experiments may detect different cluster populations. For example, Sunyaev–Zeldovich (SZ) selected cluster samples have been found to include a greater fraction of disturbed systems than X-ray selected samples. In this paper wemore » determine eight morphological parameters for the Planck Early Sunyaev–Zeldovich (ESZ) objects observed with XMM-Newton . We found that two parameters, concentration and centroid shift, are the best to distinguish between relaxed and disturbed systems. For each parameter we provide the values that allow selecting the most relaxed or most disturbed objects from a sample. We found that there is no mass dependence on the cluster dynamical state. By comparing our results with what was obtained with REXCESS clusters, we also confirm that the ESZ clusters indeed tend to be more disturbed, as found by previous studies.« less

  9. Void statistics of the CfA redshift survey

    NASA Technical Reports Server (NTRS)

    Vogeley, Michael S.; Geller, Margaret J.; Huchra, John P.

    1991-01-01

    Clustering properties of two samples from the CfA redshift survey, each containing about 2500 galaxies, are studied. A comparison of the velocity distributions via a K-S test reveals structure on scales comparable with the extent of the survey. The void probability function (VPF) is employed for these samples to examine the structure and to test for scaling relations in the galaxy distribution. The galaxy correlation function is calculated via moments of galaxy counts. The shape and amplitude of the correlation function roughly agree with previous determinations. The VPFs for distance-limited samples of the CfA survey do not match the scaling relation predicted by the hierarchical clustering models. On scales not greater than 10/h Mpc, the VPFs for these samples roughly follow the hierarchical pattern. A variant of the VPF which uses nearly all the data in magnitude-limited samples is introduced; it accounts for the variation of the sampling density with velocity in a magnitude-limited survey.

  10. Void statistics of the CfA redshift survey

    NASA Astrophysics Data System (ADS)

    Vogeley, Michael S.; Geller, Margaret J.; Huchra, John P.

    1991-11-01

    Clustering properties of two samples from the CfA redshift survey, each containing about 2500 galaxies, are studied. A comparison of the velocity distributions via a K-S test reveals structure on scales comparable with the extent of the survey. The void probability function (VPF) is employed for these samples to examine the structure and to test for scaling relations in the galaxy distribution. The galaxy correlation function is calculated via moments of galaxy counts. The shape and amplitude of the correlation function roughly agree with previous determinations. The VPFs for distance-limited samples of the CfA survey do not match the scaling relation predicted by the hierarchical clustering models. On scales not greater than 10/h Mpc, the VPFs for these samples roughly follow the hierarchical pattern. A variant of the VPF which uses nearly all the data in magnitude-limited samples is introduced; it accounts for the variation of the sampling density with velocity in a magnitude-limited survey.

  11. Protocol for determining bull trout presence

    USGS Publications Warehouse

    Peterson, James; Dunham, Jason B.; Howell, Philip; Thurow, Russell; Bonar, Scott

    2002-01-01

    The Western Division of the American Fisheries Society was requested to develop protocols for determining presence/absence and potential habitat suitability for bull trout. The general approach adopted is similar to the process for the marbled murrelet, whereby interim guidelines are initially used, and the protocols are subsequently refined as data are collected. Current data were considered inadequate to precisely identify suitable habitat but could be useful in stratifying sampling units for presence/absence surveys. The presence/absence protocol builds on previous approaches (Hillman and Platts 1993; Bonar et al. 1997), except it uses the variation in observed bull trout densities instead of a minimum threshold density and adjusts for measured differences in sampling efficiency due to gear types and habitat characteristics. The protocol consists of: 1. recommended sample sizes with 80% and 95% detection probabilities for juvenile and resident adult bull trout for day and night snorkeling and electrofishing adjusted for varying habitat characteristics for 50m and 100m sampling units, 2. sampling design considerations, including possible habitat characteristics for stratification, 3. habitat variables to be measured in the sampling units, and 3. guidelines for training sampling crews. Criteria for habitat strata consist of coarse, watershed-scale characteristics (e.g., mean annual air temperature) and fine-scale, reach and habitat-specific features (e.g., water temperature, channel width). The protocols will be revised in the future using data from ongoing presence/absence surveys, additional research on sampling efficiencies, and development of models of habitat/species occurrence.

  12. Biomonitoring of 33 Elements in Blood and Urine Samples from Coastal Populations in Sanmen County of Zhejiang Province.

    PubMed

    Zhang, Su-jing; Luo, Ru-xin; Ma, Dong; Zhuo, Xian-yi

    2016-04-01

    To determine the normal reference values of 33 elements, Ag, Al, As, Au, B, Ba, Be, Ca, Cd, Co, Cr, Cs, Cu, Fe, Ga, Hg, Li, Mg, Mn, Mo, Ni, Pb, Rb, Sb, Se, Sr, Th, Ti, Tl, U, V, Zn and Zr, in the blood and urine samples from the general population in Sanmen County of Zhejiang province, a typical coastal area of eastern China. The 33 elements in 272 blood and 300 urine samples were determined by inductively coupled plasma-mass spectrometry (ICP-MS). The normality test of data was conducted using SPSS 17.0 Statistics. The data was compared with other reports. The normal reference values of the 33 elements in the blood and urine samples from the general population in Sanmen County were obtained, which of some elements were found to be similar with other reports, such as Co, Cu, Mn and Sr, while As, Cd, Hg and Pb were generally found to be higher than those previously reported. There was a wide variation between the reports from different countries in blood Ba. The normal reference values of the 33 elements in the blood and urine samples from the general population in Sanmen County are established, and successfully applied to two poisoning cases.

  13. Exploring laser-induced breakdown spectroscopy for nuclear materials analysis and in-situ applications

    NASA Astrophysics Data System (ADS)

    Martin, Madhavi Z.; Allman, Steve; Brice, Deanne J.; Martin, Rodger C.; Andre, Nicolas O.

    2012-08-01

    Laser-induced breakdown spectroscopy (LIBS) has been used to determine the limits of detection of strontium (Sr) and cesium (Cs), common nuclear fission products. Additionally, detection limits were determined for cerium (Ce), often used as a surrogate for radioactive plutonium in laboratory studies. Results were obtained using a laboratory instrument with a Nd:YAG laser at fundamental wavelength of 1064 nm, frequency doubled to 532 nm with energy of 50 mJ/pulse. The data was compared for different concentrations of Sr and Ce dispersed in a CaCO3 (white) and carbon (black) matrix. We have addressed the sampling errors, limits of detection, reproducibility, and accuracy of measurements as they relate to multivariate analysis in pellets that were doped with the different elements at various concentrations. These results demonstrate that LIBS technique is inherently well suited for in situ analysis of nuclear materials in hot cells. Three key advantages are evident: (1) small samples (mg) can be evaluated; (2) nuclear materials can be analyzed with minimal sample preparation; and (3) samples can be remotely analyzed very rapidly (ms-seconds). Our studies also show that the methods can be made quantitative. Very robust multivariate models have been used to provide quantitative measurement and statistical evaluation of complex materials derived from our previous research on wood and soil samples.

  14. Population description and its role in the interpretation of genetic association

    PubMed Central

    Yu, Joon-Ho; Crouch, Julia; Fryer-Edwards, Kelly; Burke, Wylie

    2010-01-01

    Despite calls for greater clarity and precision of population description, studies have documented persistent ambiguity in the use of race/ethnicity terms in genetic research. It is unclear why investigators tolerate such ambiguity, or what effect these practices have on the evaluation of reported associations. To explore the way that population description is used to replicate and/or extend previously reported genetic observations, we examined articles describing the association of the peroxisome proliferator-activated receptor-gamma-γ Pro12Ala polymorphism with type 2 diabetes mellitus and related phenotypes, published between 1997 and 2005. The 80 articles identified were subjected to a detailed content analysis to determine (1) how sampled populations were described, (2) whether and how the choice of sample was explained, and (3) how the allele frequency and genetic association findings identified were contextualized and interpreted. In common with previous reports, we observed a variety of sample descriptions and little explanation for the choice of population investigated. Samples of European origin were typically described with greater specificity than samples of other origin. However, findings from European samples were nearly always compared to samples described as “Caucasian” and sometimes generalized to all Caucasians or to all humans. These findings suggest that care with population description, while important, may not fully address analytical concerns regarding the interpretation of variable study outcomes or ethical concerns regarding the attribution of genetic observations to broad social groups. Instead, criteria which help investigators better distinguish justified and unjustified forms of population generalization may be required. PMID:20157827

  15. Improved intracellular PHA determinations with novel spectrophotometric quantification methodologies based on Sudan black dye.

    PubMed

    Porras, Mauricio A; Villar, Marcelo A; Cubitto, María A

    2018-05-01

    The presence of intracellular polyhydroxyalkanoates (PHAs) is usually studied using Sudan black dye solution (SB). In a previous work it was shown that the PHA could be directly quantified using the absorbance of SB fixed by PHA granules in wet cell samples. In the present paper, the optimum SB amount and the optimum conditions to be used for SB assays were determined following an experimental design by hybrid response surface methodology and desirability-function. In addition, a new methodology was developed in which it is shown that the amount of SB fixed by PHA granules can also be determined indirectly through the absorbance of the supernatant obtained from the stained cell samples. This alternative methodology allows a faster determination of the PHA content (involving 23 and 42 min for indirect and direct determinations, respectively), and can be undertaken by means of basic laboratory equipment and reagents. The correlation between PHA content in wet cell samples and the spectra of the SB stained supernatant was determined by means of multivariate and linear regression analysis. The best calibration adjustment (R 2  = 0.91, RSE: 1.56%), and the good PHA prediction obtained (RSE = 1.81%), shows that the proposed methodology constitutes a reasonably precise way for PHA content determination. Thus, this methodology could anticipate the probable results of the above mentioned direct PHA determination. Compared with the most used techniques described in the scientific literature, the combined implementation of these two methodologies seems to be one of the most economical and environmentally friendly, suitable for rapid monitoring of the intracellular PHA content. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Concentrations of polycyclic aromatic hydrocarbons and trace elements in Arctic soils: A case-study in Svalbard.

    PubMed

    Marquès, Montse; Sierra, Jordi; Drotikova, Tatiana; Mari, Montse; Nadal, Martí; Domingo, José L

    2017-11-01

    A combined assessment on the levels and distribution profiles of polycyclic aromatic hydrocarbons (PAHs) and trace elements in soils from Pyramiden (Central Spitsbergen, Svalbard Archipelago) is here reported. As previously stated, long-range atmospheric transport, coal deposits and previous mining extractions, as well as the stack emissions of two operative power plants at this settlement are considered as potential sources of pollution. Eight top-layer soil samples were collected and analysed for the 16 US EPA priority PAHs and for 15 trace elements (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Mo, Ni, Pb, Sn, Tl, V and Zn) during late summer of 2014. The highest levels of PAHs and trace elements were found in sampling sites located near two power plants, and at downwind from these sites. The current PAH concentrations were even higher than typical threshold values. The determination of the pyrogenic molecular diagnostic ratios (MDRs) in most samples revealed that fossil fuel burning might be heavily contributing to the PAHs levels. Two different indices, the Pollution Load Index (PLI) and the Geoaccumulation Index (Igeo), were determined for assessing soil samples with respect to trace elements pollution. Samples collected close to the power plants were found to be slightly and moderately polluted with zinc (Zn) and mercury (Hg), respectively. The Spearman correlation showed significant correlations between the concentrations of 16 PAHs and some trace elements (Pb, V, Hg, Cu, Zn, Sn, Be) with the organic matter content, indicating that soil properties play a key role for pollutant retention in the Arctic soils. Furthermore, the correlations between ∑16 PAHs and some trace elements (e.g., Hg, Pb, Zn and Cu) suggest that the main source of contamination is probably pyrogenic, although the biogenic and petrogenic origin of PAHs should not be disregarded according to the local geology. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. What you see is not what you catch: a comparison of concurrently collected net, Optical Plankton Counter, and Shadowed Image Particle Profiling Evaluation Recorder data from the northeast Gulf of Mexico

    NASA Astrophysics Data System (ADS)

    Remsen, Andrew; Hopkins, Thomas L.; Samson, Scott

    2004-01-01

    Zooplankton and suspended particles were sampled in the upper 100 m of the Gulf of Mexico with the High Resolution Sampler. This towed-platform can concurrently sample zooplankton with plankton nets, an Optical Plankton Counter (OPC) and the Shadowed Image Particle Profiling and Evaluation Recorder (SIPPER), a zooplankton imaging system. This allowed for direct comparison of mesozooplankton abundance, biomass, taxonomic composition and size distributions between simultaneously collected net samples, OPC data, and digital imagery. While the net data were numerically and taxonomically similar to that of previous studies in the region, analysis of the SIPPER imagery revealed that nets significantly underestimated larvacean, doliolid, protoctist and cnidarian/ctenophore abundance by 300%, 379%, 522% and 1200%, respectively. The inefficiency of the nets in sampling the fragile and gelatinous zooplankton groups led to a dry-weight biomass estimate less than half that of the SIPPER total and suggests that this component of the zooplankton assemblage is more important than previously determined for this region. Additionally, using the SIPPER data we determined that more than 29% of all mesozooplankton-sized particles occurred within 4 mm of another particle and therefore would not be separately counted by the OPC. This suggests that coincident counting is a major problem for the OPC even at the low zooplankton abundances encountered in low latitude oligotrophic systems like the Gulf. Furthermore, we found that the colonial cyanobacterium Trichodesmium was the most abundant recognizable organism in the SIPPER dataset, while it was difficult to quantify with the nets. For these reasons, the traditional method of using net samples to ground truth OPC data would not be adequate in describing the particle assemblage described here. Consequently we suggest that in situ imaging sensors be included in any comprehensive study of mesozooplankton.

  18. Simultaneous Detection of Metalloprotease Activities in Complex Biological Samples Using the PrAMA (Proteolytic Activity Matrix Assay) Method.

    PubMed

    Conrad, Catharina; Miller, Miles A; Bartsch, Jörg W; Schlomann, Uwe; Lauffenburger, Douglas A

    2017-01-01

    Proteolytic Activity Matrix Analysis (PrAMA) is a method for simultaneously determining the activities of specific Matrix Metalloproteinases (MMPs) and A Disintegrin and Metalloproteinases (ADAMs) in complex biological samples. In mixtures of unknown proteases, PrAMA infers selective metalloproteinase activities by using a panel of moderately specific FRET-based polypeptide protease substrates in parallel, typically monitored by a plate-reader in a 96-well format. Fluorescence measurements are then quantitatively compared to a standard table of catalytic efficiencies measured from purified mixtures of individual metalloproteinases and FRET substrates. Computational inference of specific activities is performed with an easily used Matlab program, which is provided herein. Thus, we describe PrAMA as a combined experimental and mathematical approach to determine real-time metalloproteinase activities, which has previously been applied to live-cell cultures, cellular lysates, cell culture supernatants, and body fluids from patients.

  19. Determination of palladium, platinum and rhodium in geologic materials by fire assay and emission spectrography

    USGS Publications Warehouse

    Hapfty, J.; Riley, L.B.

    1968-01-01

    A method is described for the determination of palladium down to 4ppb (parts per billion, 109), platinum down to 10 ppb and rhodium down to 5 ppb in 15 g of sample. Fire-assay techniques are used to preconcentrate the platinum metals into a gold bead, then the bead is dissolved in aqua regia and diluted to volume with 1M hydrochloric acid. The solution is analysed by optical emission spectrography of the residue from 200 ??l of it evaporated on a pair of flat-top graphite electrodes. This method requires much less sample handling than most published methods for these elements. Data are presented for G-1, W-1, and six new standard rocks of the U.S. Geological Survey. The values for palladium in W-1 are in reasonable agreement with previously published data. ?? 1968.

  20. US female college students' breast health knowledge, attitudes, and determinants of screening practices: new implications for health education.

    PubMed

    Early, Jody; Armstrong, Shelley Nicole; Burke, Sloane; Thompson, Doris Lee

    2011-01-01

    This study examined female college students' knowledge, attitudes, and breast cancer screening and determined significant predictors of breast self-examination, clinical breast examination, and mammography among this population. A convenience sample of 1,074 college women from 3 universities participated in the research. Respondents completed an online version of the Toronto Breast Self-examination Instrument as well as questions developed by the authors. Descriptive statistics showed gaps in college women's knowledge of breast health and negative attitudes toward screening that were relative to age. Multiple linear and logistic regression analyses revealed that knowledge, attitudes, and copay were significant predictors of screening, whereas family history and ethnicity were not. This study supported previous smaller-sample studies that showed college women to be a priority population for breast health education and revealed new significant factors that should be addressed in health education for this group.

  1. Electron localization and optical absorption of polygonal quantum rings

    NASA Astrophysics Data System (ADS)

    Sitek, Anna; Serra, Llorenç; Gudmundsson, Vidar; Manolescu, Andrei

    2015-06-01

    We investigate theoretically polygonal quantum rings and focus mostly on the triangular geometry where the corner effects are maximal. Such rings can be seen as short core-shell nanowires, a generation of semiconductor heterostructures with multiple applications. We show how the geometry of the sample determines the electronic energy spectrum, and also the localization of electrons, with effects on the optical absorption. In particular, we show that irrespective of the ring shape low-energy electrons are always attracted by corners and are localized in their vicinity. The absorption spectrum in the presence of a magnetic field shows only two peaks within the corner-localized state domain, each associated with different circular polarization. This picture may be changed by an external electric field which allows previously forbidden transitions, and thus enables the number of corners to be determined. We show that polygonal quantum rings allow absorption of waves from distant ranges of the electromagnetic spectrum within one sample.

  2. A transient laboratory method for determining the hydraulic properties of 'tight' rocks-I. Theory

    USGS Publications Warehouse

    Hsieh, P.A.; Tracy, J.V.; Neuzil, C.E.; Bredehoeft, J.D.; Silliman, Stephen E.

    1981-01-01

    Transient pulse testing has been employed increasingly in the laboratory to measure the hydraulic properties of rock samples with low permeability. Several investigators have proposed a mathematical model in terms of an initial-boundary value problem to describe fluid flow in a transient pulse test. However, the solution of this problem has not been available. In analyzing data from the transient pulse test, previous investigators have either employed analytical solutions that are derived with the use of additional, restrictive assumptions, or have resorted to numerical methods. In Part I of this paper, a general, analytical solution for the transient pulse test is presented. This solution is graphically illustrated by plots of dimensionless variables for several cases of interest. The solution is shown to contain, as limiting cases, the more restrictive analytical solutions that the previous investigators have derived. A method of computing both the permeability and specific storage of the test sample from experimental data will be presented in Part II. ?? 1981.

  3. Extraction-Scrub-Strip test results from the interim Salt Disposition Program Macrobatch 9 Tank 21H qualification samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, T.

    2016-02-23

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 9 for the Interim Salt Disposition Program (ISDP). The Salt Batch 9 characterization results were previously reported. An Extraction-Scrub-Strip (ESS) test was performed to determine cesium distribution ratios (D (Cs)) and cesium concentration in the strip effluent and decontaminated salt solution (DSS) streams; this data will be used by Tank Farm Engineering to project a cesium decontamination factor (DF). This test used actual Tank 21H material, and a blend solvent prepared by SRNL that mimics the solvent composition currently being used atmore » the Modular Caustic-Side Solvent Extraction Unit (MCU). The ESS test showed acceptable performance with an extraction D (Cs) value of 52.4. This value is consistent with results from previous salt batch ESS tests using similar solvent formulations. This compares well against the predicted value of 56.5 from a recently created D (Cs) model« less

  4. PROBING THE ROLE OF CARBON IN ULTRAVIOLET EXTINCTION ALONG GALACTIC SIGHT LINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parvathi, V. S.; Babu, B. R. S.; Sofia, U. J.

    2012-11-20

    We report previously undetermined interstellar gas and dust-phase carbon abundances along 15 Galactic sight lines based on archival data of the strong 1334.5323 A transition observed with the Space Telescope Imaging Spectrograph. These are combined with previously reported carbon measurements along six sight lines to produce a complete sample of interstellar C II measurements determined with the 1334 A transition. Our data set includes a variety of Galactic disk environments characterized by different extinctions and samples paths ranging over three orders of magnitude in average density of hydrogen ((n(H))). Our data support the idea that dust, specifically carbon-based grains, aremore » processed in the neutral interstellar medium. We, however, do not find that the abundance of carbon in dust or the grain-size distribution is related to the strength of the 2175 A bump. This is surprising, given that many current models have polycyclic aromatic hydrocarbons as the bump-producing dust.« less

  5. Prevalence of hepatitis B and C virus infections and their related risk factors in Libya: a national seroepidemiological survey.

    PubMed

    Elzouki, A-N; Smeo, M-N; Sammud, M; Elahmer, O; Daw, M; Furarah, A; Abudher, A; Mohamed, M K

    2013-07-01

    A high prevalence of hepatitis B (HBV) and C virus (HCV) infections has been reported among specific patient groups in Libya; a survey was thus designed to determine the extent of the problem at the national level. A multi-stage sampling design covering all administrative areas of Libya was applied, covering > 65,000 individuals of all age groups. All subjects gave a blood sample and completed a questionnaire on demographic and risk behaviour data. The prevalence of HBV surface antigen (HBsAg) and anti-HCV were 2.2% and 1.3% respectively. The prevalence of anti-HCV increased with age, rising gradually after age 30 years, in contrast to a stable prevalence of HBsAg in all age groups 10+ years. Age-adjusted risk factors for HCV infection were previous hospitalization, surgical operations, previous blood transfusions and intravenous drug use; for HBV infection only family exposure or contact with HBV case were identified.

  6. Job strain and male fertility.

    PubMed

    Hjollund, Niels Henrik I; Bonde, Jens Peter E; Henriksen, Tine Brink; Giwercman, Aleksander; Olsen, Jørn

    2004-01-01

    Job strain, defined as high job demands and low job control, has not previously been explored as a possible determinant of male fertility. We collected prospective data on job strain among men, and describe the associations with semen quality and probability of conceiving a clinical pregnancy during a menstrual cycle. Danish couples (N = 399) who were trying to become pregnant for the first time were followed for up to 6 menstrual periods. All men collected semen samples, and a blood sample was drawn from both partners. Job demand and job control were measured by a self-administered questionnaire at entry, and in each cycle the participants recorded changes in job control or job demand during the previous 30 days. In adjusted analyses, no associations were found between any semen characteristic or sexual hormones and any job strain variable. The odds for pregnancy were not associated with job strain. Psychologic job strain encountered in normal jobs in Denmark does not seem to affect male reproductive function.

  7. Enzymatic Kinetic Isotope Effects from First-Principles Path Sampling Calculations.

    PubMed

    Varga, Matthew J; Schwartz, Steven D

    2016-04-12

    In this study, we develop and test a method to determine the rate of particle transfer and kinetic isotope effects in enzymatic reactions, specifically yeast alcohol dehydrogenase (YADH), from first-principles. Transition path sampling (TPS) and normal mode centroid dynamics (CMD) are used to simulate these enzymatic reactions without knowledge of their reaction coordinates and with the inclusion of quantum effects, such as zero-point energy and tunneling, on the transferring particle. Though previous studies have used TPS to calculate reaction rate constants in various model and real systems, it has not been applied to a system as large as YADH. The calculated primary H/D kinetic isotope effect agrees with previously reported experimental results, within experimental error. The kinetic isotope effects calculated with this method correspond to the kinetic isotope effect of the transfer event itself. The results reported here show that the kinetic isotope effects calculated from first-principles, purely for barrier passage, can be used to predict experimental kinetic isotope effects in enzymatic systems.

  8. Development of an analytical method for crystalline content determination in amorphous solid dispersions produced by hot-melt extrusion using transmission Raman spectroscopy: A feasibility study.

    PubMed

    Netchacovitch, L; Dumont, E; Cailletaud, J; Thiry, J; De Bleye, C; Sacré, P-Y; Boiret, M; Evrard, B; Hubert, Ph; Ziemons, E

    2017-09-15

    The development of a quantitative method determining the crystalline percentage in an amorphous solid dispersion is of great interest in the pharmaceutical field. Indeed, the crystalline Active Pharmaceutical Ingredient transformation into its amorphous state is increasingly used as it enhances the solubility and bioavailability of Biopharmaceutical Classification System class II drugs. One way to produce amorphous solid dispersions is the Hot-Melt Extrusion (HME) process. This study reported the development and the comparison of the analytical performances of two techniques, based on backscattering and transmission Raman spectroscopy, determining the crystalline remaining content in amorphous solid dispersions produced by HME. Principal Component Analysis (PCA) and Partial Least Squares (PLS) regression were performed on preprocessed data and tended towards the same conclusions: for the backscattering Raman results, the use of the DuoScan™ mode improved the PCA and PLS results, due to a larger analyzed sampling volume. For the transmission Raman results, the determination of low crystalline percentages was possible and the best regression model was obtained using this technique. Indeed, the latter acquired spectra through the whole sample volume, in contrast with the previous surface analyses performed using the backscattering mode. This study consequently highlighted the importance of the analyzed sampling volume. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Implementation of a new integrated d-lactic acid biosensor in a semiautomatic FIA system for the simultaneous determination of lactic acid enantiomers. Application to the analysis of beer samples.

    PubMed

    Vargas, E; Ruiz, M A; Campuzano, S; González de Rivera, G; López-Colino, F; Reviejo, A J; Pingarrón, J M

    2016-05-15

    An integrated amperometric d-lactic acid biosensor involving a gold film deposited by sputtering on a stainless steel disk electrode where the enzymes D-lactic acid dehydrogenase (DLDH) and diaphorase (DP) as well as the redox mediator tetrathiafulvalene (TTF) are coimmobilized by using a dialysis membrane, is reported in this work. Amperometry in stirred solutions at a detection potential of +0.15 V (vs Ag/AgCl reference electrode) provided a linear calibration plot for D-lactic acid over the 1.0×10(-4) to 3.8×10(-3) g L(-1) concentration range, with a limit of detection of 3.1×10(-5) g L(-1). The usefulness of the biosensor was demonstrated by determining D-lactic acid in beer samples with good results. Additionally, the biosensor was implemented together with a commercial L-lactic amperometric biosensor in a semiautomatic flow-injection analysis (FIA) system able to perform a rapid and simple stereo-specific determination of D- and D-lactic without a previous separation step. The operational characteristics of the biosensors under flow conditions were evaluated and its applicability was demonstrated through the simultaneous determination of both enantiomers in beer samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Q-PCR based bioburden assessment of drinking water throughout treatment and delivery to the International Space Station

    NASA Technical Reports Server (NTRS)

    Newcombe, David; Stuecker, Tara; La Duc, Myron; Venkateswaran, Kasthuri

    2005-01-01

    Previous studies indicated evidence of opportunistic pathogens samples obtained during missions to the International Space Station (ISS). This study utilized TaqMan quantitative PCR to determine specific gene abundance in potable and non-potable ISS waters. Probe and primer sets specific to the small subunit rRNA genes were used to elucidate overall bacterial rRNA gene numbers. while those specific for Burkholderia cepacia and Stenotrophomonas maltophilia were optimized and used to probe for the presence of these two opportunistic pathogens. This research builds upon previous microbial diversity studies of ISS water and demonstrates the utility of Q-PCR tool to examine water quality.

  11. Electrochemical detection of a powerful estrogenic endocrine disruptor: ethinylestradiol in water samples through bioseparation procedure.

    PubMed

    Martínez, Noelia A; Pereira, Sirley V; Bertolino, Franco A; Schneider, Rudolf J; Messina, Germán A; Raba, Julio

    2012-04-20

    The synthetic estrogen ethinylestradiol (EE2) is an active component of oral contraceptives (OCs), considered as an endocrine disrupting compound (EDC). It is excreted from humans and released via sewage treatment plant effluents into aquatic environments. EDCs are any environmental pollutant chemical that, once incorporated into an organism, affects the hormonal balance of various species including humans. Its presence in the environment is becoming of great importance in water quality. This paper describes the development of an accurate, sensitive and selective method for capture, preconcentration and determination of EE2 present in water samples using: magnetic particles (MPs) as bioaffinity support for the capture and preconcentration of EE2 and a glassy carbon electrode modified with multi-walled carbon nanotubes (MWCNTs/GCE) as detection system. The capture procedure was based on the principle of immunoaffinity, the EE2 being extracted from the sample using the anti-EE2 antibodies (anti-EE2 Ab) which were previously immobilized on MPs. Subsequently the analyte desorption was done employing a sulfuric acid solution and the determination of the EE2 in the pre-concentrated solution was carried out by square wave voltammetry (SWV). This method can be used to determine EE2 in the range of 0.035-70 ng L(-1) with a detection limit (LOD) of 0.01 ng L(-1) and R.S.D.<4.20%. The proposed method has been successfully applied to the determination of EE2 in water samples and it has promising analytical applications for the direct determination of EE2 at trace levels. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Microbiological Assessment of Bile and Corresponding Antibiotic Treatment: A Strobe-Compliant Observational Study of 1401 Endoscopic Retrograde Cholangiographies.

    PubMed

    Rupp, Christian; Bode, Konrad; Weiss, Karl Heinz; Rudolph, Gerda; Bergemann, Janine; Kloeters-Plachky, Petra; Chahoud, Fadi; Stremmel, Wolfgang; Gotthardt, Daniel Nils; Sauer, Peter

    2016-03-01

    The aim of this study was to determine the antibiotic susceptibility profiles of bacteria in bile samples and to analyze the clinical relevance of the findings as only limited information about risk factors for elevated frequence of bacterial and fungal strains in routinely collected bile samples has been described so far.A prospective cohort study at a tertiary care center was conducted. Seven hundred forty-four patients underwent 1401 endoscopic retrograde cholangiographies (ERCs) as indicated by liver transplantation (427/1401), primary sclerosing cholangitis (222/1401), choledocholithiasis only (153/1401), obstruction due to malignancy (366/1401), or other conditions (233/1401). Bile samples for microbiological analysis were obtained in all patients.The 71.6% (823/1150) samples had a positive microbiological finding, and 57% (840/1491) of the bacterial isolates were gram-positive. The main species were Enterococcus spp (33%; 494/1491) and Escherichia coli (12%; 179/1491). Of the samples, 53.8% had enteric bacteria and 24.7% had Candida spp; both were associated with clinical and laboratory signs of cholangitis (C-reactive proteins 35.0 ± 50.1 vs 44.8 ± 57.6; 34.5 ± 51.2 vs 52.9 ± 59.7; P < 0.001), age, previous endoscopic intervention, and immunosuppression. Multi-resistant (MR) strains were found in 11.3% of all samples and were associated with clinical and laboratory signs of cholangitis, previous intervention, and immunocompromised status. In subgroup analysis, strain-specific antibiotic therapy based on bile sampling was achieved in 56.3% (89/158) of the patients. In cases with a positive bile culture and available blood culture, blood cultures were positive in 29% of cases (36/124), and 94% (34/36) of blood cultures had microbial species identical to the bile cultures.Bactobilia and fungobilia can usually be detected by routine microbiological sampling, allowing optimized, strain-specific antibiotic treatment. Previous endoscopic intervention, clinical and laboratory signs of cholangitis, and age are independent risk factors. MR bacteria and fungi are an evolving problem in cholangitis, especially in immunocompromised patients.

  13. Microbiological Assessment of Bile and Corresponding Antibiotic Treatment

    PubMed Central

    Rupp, Christian; Bode, Konrad; Weiss, Karl Heinz; Rudolph, Gerda; Bergemann, Janine; Kloeters-Plachky, Petra; Chahoud, Fadi; Stremmel, Wolfgang; Gotthardt, Daniel Nils; Sauer, Peter

    2016-01-01

    Abstract The aim of this study was to determine the antibiotic susceptibility profiles of bacteria in bile samples and to analyze the clinical relevance of the findings as only limited information about risk factors for elevated frequence of bacterial and fungal strains in routinely collected bile samples has been described so far. A prospective cohort study at a tertiary care center was conducted. Seven hundred forty-four patients underwent 1401 endoscopic retrograde cholangiographies (ERCs) as indicated by liver transplantation (427/1401), primary sclerosing cholangitis (222/1401), choledocholithiasis only (153/1401), obstruction due to malignancy (366/1401), or other conditions (233/1401). Bile samples for microbiological analysis were obtained in all patients. The 71.6% (823/1150) samples had a positive microbiological finding, and 57% (840/1491) of the bacterial isolates were gram-positive. The main species were Enterococcus spp (33%; 494/1491) and Escherichia coli (12%; 179/1491). Of the samples, 53.8% had enteric bacteria and 24.7% had Candida spp; both were associated with clinical and laboratory signs of cholangitis (C-reactive proteins 35.0 ± 50.1 vs 44.8 ± 57.6; 34.5 ± 51.2 vs 52.9 ± 59.7; P < 0.001), age, previous endoscopic intervention, and immunosuppression. Multi-resistant (MR) strains were found in 11.3% of all samples and were associated with clinical and laboratory signs of cholangitis, previous intervention, and immunocompromised status. In subgroup analysis, strain-specific antibiotic therapy based on bile sampling was achieved in 56.3% (89/158) of the patients. In cases with a positive bile culture and available blood culture, blood cultures were positive in 29% of cases (36/124), and 94% (34/36) of blood cultures had microbial species identical to the bile cultures. Bactobilia and fungobilia can usually be detected by routine microbiological sampling, allowing optimized, strain-specific antibiotic treatment. Previous endoscopic intervention, clinical and laboratory signs of cholangitis, and age are independent risk factors. MR bacteria and fungi are an evolving problem in cholangitis, especially in immunocompromised patients. PMID:26962768

  14. Human polyomavirus 9 in immunocompromised patients in the University Hospital in Hradec Kralove, Czech Republic.

    PubMed

    Fajfr, Miroslav; Pliskova, Lenka; Kutova, Radka; Matyskova-Kubisova, Michaela; Navratil, Pavel; Radocha, Jakub; Valenta, Zbynek; Dusilova-Sulkova, Sylvie

    2017-12-01

    Human polyomaviruses such as JC polyomavirus and BK polyomavirus have long been well known pathogens of immunocompromised patients. Several new members of this viral family have been described during the last decade. Human polyomavirus 9 seems to be a novel pathogen of transplanted patients according to some studies. The aim of our study was to determine the presence of human polyomavirus 9 in patients after kidney or stem cell transplantation (SCT) at the University Hospital in Hradec Kralove, Czech Republic. Overall 100 patients, 65 after kidney transplantation and 35 after SCT, were included into the study. At least three follow-up samples from each patient were examined for human polyomavirus 9 DNA presentation with the two previously described in-house PCR protocols. Despite the frequent reactivation of human CMV (14.3% in kidney transplantation and 63.3% after SCT) or BK polyomavirus in our patient group, there was no positivity for human polyomavirus 9 either in blood samples or urine samples. One of the possible reasons for this discrepancy versus previous published studies could be a relatively low proportion of patients treated by induction therapy before kidney transplantation in our study cohort. © 2017 Wiley Periodicals, Inc.

  15. Amchitka Island, Alaska, special sampling project 1997

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    U.S. Department of Energy, Nevada Operations Office

    2000-06-28

    This 1997 special sampling project represents a special radiobiological sampling effort to augment the 1996 Long-Term Hydrological Monitoring Program (LTHMP) for Amchitka Island in Alaska. Lying in the western portion of the Aleutian Islands arc, near the International Date Line, Amchitka Island is one of the southernmost islands of the Rat Island Chain. Between 1965 and 1971, the U.S. Atomic Energy Commission conducted three underground nuclear tests on Amchitka Island. In 1996, Greenpeace collected biota samples and speculated that several long-lived, man-made radionuclides detected (i.e., americium-241, plutonium-239 and -240, beryllium-7, and cesium-137) leaked into the surface environment from underground cavitiesmore » created during the testing. The nuclides of interest are detected at extremely low concentrations throughout the environment. The objectives of this special sampling project were to scientifically refute the Greenpeace conclusions that the underground cavities were leaking contaminants to the surface. This was achieved by first confirming the presence of these radionuclides in the Amchitka Island surface environment and, second, if the radionuclides were present, determining if the source is the underground cavity or worldwide fallout. This special sampling and analysis determined that the only nonfallout-related radionuclide detected was a low level of tritium from the Long Shot test, which had been previously documented. The tritium contamination is monitored and continues a decreasing trend due to radioactive decay and dilution.« less

  16. Rapid and reliable determination of the halogenating peroxidase activity in blood samples.

    PubMed

    Flemmig, Jörg; Schwarz, Pauline; Bäcker, Ingo; Leichsenring, Anna; Lange, Franziska; Arnhold, Jürgen

    2014-12-15

    By combining easy and fast leukocyte enrichment with aminophenyl-fluorescein (APF) staining we developed a method to quickly and specifically address the halogenating activity of the immunological relevant blood heme peroxidases myeloperoxidase and eosinophil peroxidase, respectively. For leukocyte enrichment a two-fold hypotonic lysis procedure of the blood with Millipore water was chosen which represents a cheap, fast and reliable method to diminish the amount of erythrocytes in the samples. This procedure is shown to be suitable both to human and murine blood micro-samples, making it also applicable to small animal experiments with recurring blood sampling. As all types of leukocytes are kept in the sample during the preparation, they can be analysed separately after discrimination during the flow cytometry analysis. This also holds for all heme peroxidase-containing cells, namely neutrophils, eosinophils and monocytes. Moreover additional parameters (e.g. antibody staining) can be combined with the heme peroxidase activity determination to gain additional information about the different immune cell types. Based on previous results we applied APF for specifically addressing the halogenating activity of leukocyte peroxidases in blood samples. This dye is selectively oxidized by the MPO and EPO halogenation products hypochlorous and hypobromous acid. This approach may provide a suitable tool to gain more insights into the immune-physiological role of the halogenating activity of heme peroxidases. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Ultra-trace determination of Strontium-90 in environmental soil samples from Qatar by collision/reaction cell-inductively coupled plasma mass spectrometry (CRC-ICP-MS/MS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Al-Meer, S. H.; Amr, M. A.; Helal, A.I.

    Because of the very low level of {sup 90}Sr in the environmental soil samples and its determination by beta counting may take several weeks, we developed a procedure for ultra-trace determination of {sup 90}Sr using collision reaction cell-inductively coupled plasma tandem mass spectrometry (CRC-ICP-MS/MS, Agilent 8800). Soil samples were dried at 105 deg. C and then heated in a furnace at 550 deg. C to remove any organics present. 500 g of each soil samples were aliquoted into 2000 ml glass beakers. Each Soils samples were soaked in 2 ppm Sr solution carrier to allow determination of chemical yield. Themore » solid to liquid ratio was 1:1. Finally the soil samples were dried at 105 deg. C. Five hundred milliliters concentrated nitric acid and 250 ml hydrochloric acid volumes were added on 500 g soil samples. The samples were digested on hot plate at 80 deg. C to prevent spraying with continuous manual mixing. The leachate solution was separated. The solids were rinsed with 500 ml deionized water, warmed on a hot plate and the leachate plus previous leachate were filtered and the total volume was reduced to 500 ml by evaporation. Final leachate volume was transferred to a centrifuge tubes. The centrifuge tubes were centrifuged at 3,500 rpm for 10 min. The leachate was transferred to a 1 L beaker and heated on a hot plate to evaporate the leachate to dryness. The reside was re-dissolved in 100 ml of 2% HNO{sub 3} and reduced by evaporation to 10 mL. The solution was measured directly by CRC-ICP-MS/MS by setting the first quadruple analyzer to m/z 90 and introducing oxygen gas into the reaction cell for elimination isobar interference from zirconium-90. The method was validated by measurements of standard reference materials and applied on environmental soil samples. The overall time requirement for the measurement of strontium-90 by CRC-ICP-MS/MS is 2 days, significantly shorter than any radioanalytical protocol currently available. (authors)« less

  18. Associated with aerospace vehicles development of methodologies for the estimation of thermal properties

    NASA Technical Reports Server (NTRS)

    Scott, Elaine P.

    1994-01-01

    Thermal stress analyses are an important aspect in the development of aerospace vehicles at NASA-LaRC. These analyses require knowledge of the temperature distributions within the vehicle structures which consequently necessitates the need for accurate thermal property data. The overall goal of this ongoing research effort is to develop methodologies for the estimation of the thermal property data needed to describe the temperature responses of these complex structures. The research strategy undertaken utilizes a building block approach. The idea here is to first focus on the development of property estimation methodologies for relatively simple conditions, such as isotropic materials at constant temperatures, and then systematically modify the technique for the analysis of more and more complex systems, such as anisotropic multi-component systems. The estimation methodology utilized is a statistically based method which incorporates experimental data and a mathematical model of the system. Several aspects of this overall research effort were investigated during the time of the ASEE summer program. One important aspect involved the calibration of the estimation procedure for the estimation of the thermal properties through the thickness of a standard material. Transient experiments were conducted using a Pyrex standard at various temperatures, and then the thermal properties (thermal conductivity and volumetric heat capacity) were estimated at each temperature. Confidence regions for the estimated values were also determined. These results were then compared to documented values. Another set of experimental tests were conducted on carbon composite samples at different temperatures. Again, the thermal properties were estimated for each temperature, and the results were compared with values obtained using another technique. In both sets of experiments, a 10-15 percent off-set between the estimated values and the previously determined values was found. Another effort was related to the development of the experimental techniques. Initial experiments required a resistance heater placed between two samples. The design was modified such that the heater was placed on the surface of only one sample, as would be necessary in the analysis of built up structures. Experiments using the modified technique were conducted on the composite sample used previously at different temperatures. The results were within 5 percent of those found using two samples. Finally, an initial heat transfer analysis, including conduction, convection and radiation components, was completed on a titanium sandwich structural sample. Experiments utilizing this sample are currently being designed and will be used to first estimate the material's effective thermal conductivity and later to determine the properties associated with each individual heat transfer component.

  19. High precision calcium isotope analysis using 42Ca-48Ca double-spike TIMS technique

    NASA Astrophysics Data System (ADS)

    Feng, L.; Zhou, L.; Gao, S.; Tong, S. Y.; Zhou, M. L.

    2014-12-01

    Double spike techniques are widely used for determining calcium isotopic compositions of natural samples. The most important factor controlling precision of the double spike technique is the choice of appropriate spike isotope pair, the composition of double spikes and the ratio of spike to sample(CSp/CN). We propose an optimal 42Ca-48Ca double spike protocol which yields the best internal precision for calcium isotopic composition determinations among all kinds of spike pairs and various spike compositions and ratios of spike to sample, as predicted by linear error propagation method. It is suggested to use spike composition of 42Ca/(42Ca+48Ca) = 0.44 mol/mol and CSp/(CN+ CSp)= 0.12mol/mol because it takes both advantages of the largest mass dispersion between 42Ca and 48Ca (14%) and lowest spike cost. Spiked samples were purified by pass through homemade micro-column filled with Ca special resin. K, Ti and other interference elements were completely separated, while 100% calcium was recovered with negligible blank. Data collection includes integration time, idle time, focus and peakcenter frequency, which were all carefully designed for the highest internal precision and lowest analysis time. All beams were automatically measured in a sequence by Triton TIMS so as to eliminate difference of analytical conditions between samples and standards, and also to increase the analytical throughputs. The typical internal precision of 100 duty cycles for one beam is 0.012‒0.015 ‰ (2δSEM), which agrees well with the predicted internal precision of 0.0124 ‰ (2δSEM). Our methods improve internal precisions by a factor of 2‒10 compared to previous methods of determination of calcium isotopic compositions by double spike TIMS. We analyzed NIST SRM 915a, NIST SRM 915b and Pacific Seawater as well as interspersed geological samples during two months. The obtained average δ44/40Ca (all relative to NIST SRM 915a) is 0.02 ± 0.02 ‰ (n=28), 0.72±0.04 ‰ (n=10) and 1.93±0.03 ‰ (n=21) for NIST SRM 915a, NIST SRM 915b and Pacific Seawater, respectively. The long-term reproducibility is 0.10‰ (2 δSD), which is comparable to the best external precision of 0.04 ‰ (2 δSD) of previous methods, but our sample throughputs are doubled with significant reduction in amount of spike used for single samples.

  20. Interstitial water studies on small core samples, Deep Sea Drilling Project, Leg 6

    USGS Publications Warehouse

    Manheim, F. T.; Sayles, F.L.

    1971-01-01

    Sediments from Leg 6 sites, west of the Hawaiian Islands, consisted primarily of various combinations of deep-sea biogenic oozes, volcanic ash, and its breakdown products. Pore fluids from most of the sites were similar in composition to present day ocean water, and in some sties almost identical. However, interstitial fluids from Site 53 (Philippine Sea) showed changes in ionic composition which were beyond those previously considered attributable to diagenetic influence. These samples show the beginnings of metamorphism by dramatic increases in calcium concentrations and corresponding decreases in alkali concentrations. Analytical methods were similar to those outlined in previous Leg Reports. However, obvious contamination of aliquots for sodium determination in the laboratory made it necessary to determine all sodium values by difference between anion and cation balances. These values are, if anything, more accurate than direct determinations which have been discussed in earlier legs. However, the authors will continue to analyze sodium directly, and in the future they may be able to improve the precision of the determinations to the point where small losses and gains of sodium in the pore fluids may be established accurately. Agreement between colorimetric and spectrometric determinations of silicon has improved, but there are still occasional marked differences for which the writers have no explanation. T. Takahashi has allowed the authors to compare total Carbon Dioxide (CO2) measurements from his laboratory with their alkalinity determinations: both sets of data were obtained from fluids from the same squeezings of sediments and should give similar values at the indicated pH levels. Some disturbingly large discrepancies in the two sets of data are evident. The authors do not think that their back-titration alkalinity technique alone is responsible for the differences. However, they have not evaluated the possible influence of the heat-sealed polyethylene pipes on the alkalinity values; this should be considered a potential source of error. The pH data from water samples processed and measured on shipboard are reported here. In view of the major changes in pressure and temperature (laboratory temperatures were reported to be 26 to 28°C) and the sediments to new gaseous regimes prior to pH measurement, these values should be interpreted mainly as applying to the squeezed effluents, not to in situ values.

  1. Zeeman splitting of 6.7 GHz methanol masers. On the uncertainty of magnetic field strength determinations

    NASA Astrophysics Data System (ADS)

    Vlemmings, W. H. T.; Torres, R. M.; Dodson, R.

    2011-05-01

    Context. To properly determine the role of magnetic fields during massive star formation, a statistically significant sample of field measurements probing different densities and regions around massive protostars needs to be established. However, relating Zeeman splitting measurements to magnetic field strengths needs a carefully determined splitting coefficient. Aims: Polarization observations of, in particular, the very abundant 6.7 GHz methanol maser, indicate that these masers appear to be good probes of the large scale magnetic field around massive protostars at number densities up to nH2 ≈ 109 cm-3. We thus investigate the Zeeman splitting of the 6.7 GHz methanol maser transition. Methods: We have observed of a sample of 46 bright northern hemisphere maser sources with the Effelsberg 100-m telescope and an additional 34 bright southern masers with the Parkes 64-m telescope in an attempt to measure their Zeeman splitting. We also revisit the previous calculation of the methanol Zeeman splitting coefficients and show that these were severely overestimated making the determination of magnetic field strengths highly uncertain. Results: In total 44 of the northern masers were detected and significant splitting between the right- and left-circular polarization spectra is determined in >75% of the sources with a flux density >20 Jy beam-1. Assuming the splitting is due to a magnetic field according to the regular Zeeman effect, the average detected Zeeman splitting corrected for field geometry is ~0.6 m s-1. Using an estimate of the 6.7 GHz A-type methanol maser Zeeman splitting coefficient based on old laboratory measurements of 25 GHz E-type methanol transitions this corresponds to a magnetic field of ~120 mG in the methanol maser region. This is significantly higher than expected using the typically assumed relation between magnetic field and density (B∝ n_H_20.47) and potentially indicates the extrapolation of the available laboratory measurements is invalid. The stability of the right- and left-circular calibration of the Parkes observations was insufficient to determine the Zeeman splitting of the Southern sample. Spectra are presented for all sources in both samples. Conclusions: There is no strong indication that the measured splitting between right- and left-circular polarization is due to non-Zeeman effects, although this cannot be ruled out until the Zeeman coefficient is properly determined. However, although the 6.7 GHz methanol masers are still excellent magnetic field morphology probes through linear polarization observations, previous derivations of magnetic fields strength turn out to be highly uncertain. A solution to this problem will require new laboratory measurements of the methanol Landé-factors. Table 2 and Figs. 5-7 are only available in electronic form at http://www.aanda.org

  2. The Incidence of Human Papillomavirus in Tanzanian Adolescent Girls Before Reported Sexual Debut.

    PubMed

    Houlihan, Catherine F; Baisley, Kathy; Bravo, Ignacio G; Kapiga, Saidi; de Sanjosé, Silvia; Changalucha, John; Ross, David A; Hayes, Richard J; Watson-Jones, Deborah

    2016-03-01

    Acquisition of human papillomavirus (HPV) in women occurs predominantly through vaginal sex. However, HPV has been detected in girls reporting no previous sex. We aimed to determine incidence and risk factors for HPV acquisition in girls who report no previous sex in Tanzania, a country with high HPV prevalence and cervical cancer incidence. We followed 503 adolescent girls aged 15-16 years in Mwanza, Tanzania, with face-to-face interviews and self-administered vaginal swabs every 3 months for 18 months; 397 girls reported no sex before enrollment or during follow-up; of whom, 120 were randomly selected. Samples from enrollment, 6-, 12-, and 18-month visits were tested for 37 HPV genotypes. Incidence, clearance, point prevalence, and duration of any HPV and genotype-specific infections were calculated and associated factors were evaluated. Of 120 girls who reported no previous sex, 119 were included, contributing 438 samples. HPV was detected in 51 (11.6%) samples. The overall incidence of new HPV infections was 29.4/100 person-years (95% confidence interval: 15.9-54.2). The point prevalence of vaccine types HPV-6,-11,-16, and -18 was .9%, .9%, 2.0%, and 0%, respectively. Spending a night away from home and using the Internet were associated with incident HPV, and reporting having seen a pornographic movie was inversely associated with HPV incidence. Incident HPV infections were detected frequently in adolescent girls who reported no previous sex over 18 months. This is likely to reflect under-reporting of sex. A low-point prevalence of HPV genotypes in licensed vaccines was seen, indicating that vaccination of these girls might still be effective. Copyright © 2016 Society for Adolescent Health and Medicine. All rights reserved.

  3. The Incidence of Human Papillomavirus in Tanzanian Adolescent Girls Before Reported Sexual Debut

    PubMed Central

    Houlihan, Catherine F.; Baisley, Kathy; Bravo, Ignacio G.; Kapiga, Saidi; de Sanjosé, Silvia; Changalucha, John; Ross, David A.; Hayes, Richard J.; Watson-Jones, Deborah

    2016-01-01

    Purpose Acquisition of human papillomavirus (HPV) in women occurs predominantly through vaginal sex. However, HPV has been detected in girls reporting no previous sex. We aimed to determine incidence and risk factors for HPV acquisition in girls who report no previous sex in Tanzania, a country with high HPV prevalence and cervical cancer incidence. Methods We followed 503 adolescent girls aged 15–16 years in Mwanza, Tanzania, with face-to-face interviews and self-administered vaginal swabs every 3 months for 18 months; 397 girls reported no sex before enrollment or during follow-up; of whom, 120 were randomly selected. Samples from enrollment, 6-, 12-, and 18-month visits were tested for 37 HPV genotypes. Incidence, clearance, point prevalence, and duration of any HPV and genotype-specific infections were calculated and associated factors were evaluated. Results Of 120 girls who reported no previous sex, 119 were included, contributing 438 samples. HPV was detected in 51 (11.6%) samples. The overall incidence of new HPV infections was 29.4/100 person-years (95% confidence interval: 15.9–54.2). The point prevalence of vaccine types HPV-6,-11,-16, and -18 was .9%, .9%, 2.0%, and 0%, respectively. Spending a night away from home and using the Internet were associated with incident HPV, and reporting having seen a pornographic movie was inversely associated with HPV incidence. Conclusions Incident HPV infections were detected frequently in adolescent girls who reported no previous sex over 18 months. This is likely to reflect under-reporting of sex. A low-point prevalence of HPV genotypes in licensed vaccines was seen, indicating that vaccination of these girls might still be effective. PMID:26725717

  4. Liquid sample delivery techniques for serial femtosecond crystallography

    PubMed Central

    Weierstall, Uwe

    2014-01-01

    X-ray free-electron lasers overcome the problem of radiation damage in protein crystallography and allow structure determination from micro- and nanocrystals at room temperature. To ensure that consecutive X-ray pulses do not probe previously exposed crystals, the sample needs to be replaced with the X-ray repetition rate, which ranges from 120 Hz at warm linac-based free-electron lasers to 1 MHz at superconducting linacs. Liquid injectors are therefore an essential part of a serial femtosecond crystallography experiment at an X-ray free-electron laser. Here, we compare different techniques of injecting microcrystals in solution into the pulsed X-ray beam in vacuum. Sample waste due to mismatch of the liquid flow rate to the X-ray repetition rate can be addressed through various techniques. PMID:24914163

  5. A Comprehensive Characterization of Microorganisms and Allergens in Spacecraft Environment

    NASA Technical Reports Server (NTRS)

    Castro, V.A.; Ott, C.M.; Garcia, V.M.; John, J.; Buttner, M.P.; Cruz, P.; Pierson, D.L.

    2009-01-01

    The determination of risk from infectious disease during long-duration missions is composed of several factors including the concentration and the characteristics of the infectious agent. Thus, a thorough knowledge of the microorganisms aboard spacecraft is essential in mitigating infectious disease risk to the crew. While stringent steps are taken to minimize the transfer of potential pathogens to spacecraft, several medically significant organisms have been isolated from both the Mir and International Space Station (ISS). Historically, the method for isolation and identification of microorganisms from spacecraft environmental samples depended upon their growth on culture media. Unfortunately, only a fraction of the organisms may grow on a culture medium, potentially omitting those microorganisms whose nutritional and physical requirements for growth are not met. Thus, several pathogens may not have been detected, such as Legionella pneumophila, the etiological agent of Legionnaire s disease. We hypothesize that environmental analysis using non-culture-based technologies will reveal microorganisms, allergens, and microbial toxins not previously reported in spacecraft, allowing for a more complete health assessment. The development of techniques for this flight experiment, operationally named SWAB, has already provided advances in NASA laboratory processes and beneficial information toward human health risk assessment. The translation of 16S ribosomal DNA sequencing for the identification of bacteria from the SWAB experiment to nominal operations has increased bacterial speciation of environmental isolates from previous flights three fold compared to previous conventional methodology. The incorporation of molecular-based DNA fingerprinting using repetitive sequence-based polymerase chain reaction (rep-PCR) into the capabilities of the laboratory has provided a methodology to track microorganisms between crewmembers and their environment. Both 16S ribosomal DNA identification and bacterial fingerprinting have improved NASA s capability to better understand spacecraft environments and determine the source of contamination events. Preflight sampling has been completed for air, surface, and water samples. In-flight sample collection has been completed for a total of 8 air and surface sample collection sessions. In-flight hardware has performed well and the surface sampling device received positive feedback from the crew for its ease of use. While processing and analysis continue for these samples, early results have begun to provide information on the spacecraft environment. Using a method called Denaturing Gradient Gel Electrophoresis (DGGE), several air and samples were evaluated to determine the types of organisms that were present. Using only molecular techniques, DGGE does not depend on any microbial growth on culture media, allowing a more comprehensive assessment of the spacecraft interior. Preliminary results have identified several microorganisms that would not have been isolated using current technology, though none of these organisms would be considered medically significant. Interestingly, the isolation of Gram negative organisms is greater using DGGE than conventional media based isolation. The cause of this finding is unclear, though it may be the result of the technique s ability to isolate both viable and non-viable bacteria. The next phase of the SWAB sample analysis is the use of quantitative polymerase chain reaction (QPCR) to look for specific medically significant organisms. While not as broad as DGGE, QPCR is much more sensitive and may reveal findings that were not seen during the initial evaluation. Together, this information will lead toward an accurate microbial risk assessment to help set flight requirements to protect the safety, health, and performance of the crew.

  6. Environmental Aspects of Artificial Aeration and Oxygenation of Reservoirs: A Review of Theory, Techniques, and Experiences.

    DTIC Science & Technology

    1982-05-01

    Characteristics of USAE Reservoirs and Artificially Mixed Reservoirs 143 4 19 Correlation Matrix for USAE Reservoir Characteristics 149 20 Disadvantages...previously. The pH of water has additional roles in directly determining species distributions and in controlling activity of phytoplankton diseases. 143 ...see text under "Review of Mixing Experiences" for explanation). c Range of median values from three sampling dates during summer. 143

  7. Studies of CO oxidation on Pt/SnO2 catalyst in a surrogate CO2 laser facility

    NASA Technical Reports Server (NTRS)

    Batten, Carmen E.; Miller, Irvin M.; Paulin, Patricia A.; Schryer, Jacqueline

    1987-01-01

    Samples of 1% Pt/SnO2 catalyst were exposed to a stoichiometric gas mixture of 1% CO and 1.2% O2 in helium over a range of flowrates from 5 to 15 sccm and temperatures from 338 to 394 Kelvin. Reaction rate constants for the catalytic oxidation of carbon monoxide and their temperature dependence were determined and compared with previous literature values.

  8. Neutral ion sources in precision manufacturing

    NASA Technical Reports Server (NTRS)

    Fawcett, Steven C.; Drueding, Thomas W.

    1994-01-01

    Ion figuring of optical components is a relatively new technology that can alleviate some of the problems associated with traditional contact polishing. Because the technique is non contacting, edge distortions and rib structure print through do not occur. This initial investigation was aimed at determining the effect of ion figuring on surface roughness of previously polished or ductile ground ceramic optical samples. This is the first step in research directed toward the combination of a pre-finishing process (ductile grinding or polishing) with ion figuring to produce finished ceramic mirrors. The second phase of the project is focusing on the development of mathematical algorithms that will deconvolve the ion beam profile from the surface figure errors so that these errors can be successfully removed from the optical components. In the initial phase of the project, multiple, chemical vapor deposited silicon carbide (CVD SiC) samples were polished or ductile ground to specular or near-specular roughness. These samples were then characterized to determine topographic surface information. The surface evaluation consisted of stylus profilometry, interferometry, and optical and scanning electron microscopy. The surfaces, were ion machined to depths from 0-5 microns. The finished surfaces were characterized to evaluate the effects of the ion machining process with respect to the previous processing methods and the pre-existing subsurface damage. The development of the control algorithms for figuring optical components has been completed. These algorithms have been validated with simulations and future experiments have been planned to verify the methods. This paper will present the results of the initial surface finish experiments and the control algorithms simulations.

  9. Validation of an optimized method for the determination of iodine in human breast milk by inductively coupled plasma mass spectrometry (ICPMS) after tetramethylammonium hydroxide extraction.

    PubMed

    Huynh, Dao; Zhou, Shao Jia; Gibson, Robert; Palmer, Lyndon; Muhlhausler, Beverly

    2015-01-01

    In this study a novel method to determine iodine concentrations in human breast milk was developed and validated. The iodine was analyzed by inductively coupled plasma mass spectrometry (ICPMS) following tetramethylammonium hydroxide (TMAH) extraction at 90°C in disposable polypropylene tubes. While similar approaches have been used previously, this method adopted a shorter extraction time (1h vs. 3h) and used antimony (Sb) as the internal standard, which exhibited greater stability in breast milk and milk powder matrices compared to tellurium (Te). Method validation included: defining iodine linearity up to 200μgL(-1); confirming recovery of iodine from NIST 1549 milk powder. A recovery of 94-98% was also achieved for the NIST 1549 milk powder and human breast milk samples spiked with sodium iodide and thyroxine (T4) solutions. The method quantitation limit (MQL) for human breast milk was 1.6μgL(-1). The intra-assay and inter-assay coefficient of variation for the breast milk samples and NIST powder were <1% and <3.5%, respectively. NIST 1549 milk powder, human breast milk samples and calibration standards spiked with the internal standard were all stable for at least 2.5 months after extraction. The results of the validation process confirmed that this newly developed method provides greater accuracy and precision in the assessment of iodine concentrations in human breast milk than previous methods and therefore offers a more reliable approach for assessing iodine concentrations in human breast milk. Copyright © 2014 Elsevier GmbH. All rights reserved.

  10. Relationship between Menthiafolic Acid and Wine Lactone in Wine.

    PubMed

    Giaccio, Joanne; Curtin, Chris D; Sefton, Mark A; Taylor, Dennis K

    2015-09-23

    Menthiafolic acid (6-hydroxy-2,6-dimethylocta-2,7-dienoic acid, 2a) was quantified by GC-MS in 28 white wines, 4 Shiraz wines, and for the first time in 6 white grape juice samples. Menthiafolic acid was detected in all but one of the wine samples at concentrations ranging from 26 to 342 μg/L and in the juice samples from 16 to 236 μg/L. Various model fermentation experiments showed that some menthiafolic acid in wine could be generated from the grape-derived menthiafolic acid glucose ester (2b) during alcoholic and malolactic fermentation. Samples containing high concentrations of menthiafolic acid were also analyzed by enantioselective GC-MS and were shown to contain this compound in predominantly the (S)-configuration. Enantioselective analysis of wine lactone (1) in one of these samples, a four-year-old Chardonnay wine showed, for the first time, the presence of the 3R,3aR,7aS isomer of wine lactone (1b), which is the enantiomer of the form previously reported as the sole isomer present in young wine samples. The weakly odorous 3R,3aR,7aS 1b form comprised 69% of the total wine lactone in the sample. On the basis of the enantioselectivity of the hydrolytic conversion of menthiafolic acid to wine lactone at pH 3.0 determined previously and the relative proportions of (R)- and (S)-menthiafolic acid in the Chardonnay wine, the predicted ratio of wine lactone enantiomers that would be formed from hydrolysis at ambient temperature of the menthiafolic acid present in this wine was close to the ratio measured, which was consistent with menthiafolic acid being the major or sole precursor to wine lactone in this sample.

  11. Multilocus phylogeographic assessment of the California Mountain Kingsnake (Lampropeltis zonata) suggests alternative patterns of diversification for the California Floristic Province.

    PubMed

    Myers, E A; Rodríguez-Robles, J A; Denardo, D F; Staub, R E; Stropoli, A; Ruane, S; Burbrink, F T

    2013-11-01

    Phylogeographic inference can determine the timing of population divergence, historical demographic processes, patterns of migration, and when extended to multiple species, the history of communities. Single-locus analyses can mislead interpretations of the evolutionary history of taxa and comparative analyses. It is therefore important to revisit previous single-locus phylogeographic studies, particularly those that have been used to propose general patterns for regional biotas and the processes responsible for generating inferred patterns. Here, we employ a multilocus statistical approach to re-examine the phylogeography of Lampropeltis zonata. Using nonparametic and Bayesian species delimitation, we determined that there are two well-supported species within L. zonata. Ecological niche modelling supports the delimitation of these taxa, suggesting that the two species inhabit distinct climatic environments. Gene flow between the two taxa is low and appears to occur unidirectionally. Further, our data suggest that gene flow was mediated by females, a rare pattern in snakes. In contrast to previous analyses, we determined that the divergence between the two lineages occurred in the late Pliocene (c. 2.07 Ma). Spatially and temporally, the divergence of these lineages is associated with the inundation of central California by the Monterey Bay. The effective population sizes of the two species appear to have been unaffected by Pleistocene glaciation. Our increased sampling of loci for L. zonata, combined with previously published multilocus analyses of other sympatric species, suggests that previous conclusions reached by comparative phylogeographic studies conducted within the California Floristic Province should be reassessed. © 2013 John Wiley & Sons Ltd.

  12. In situ photoacoustic characterization for porous silicon growing: Detection principles

    NASA Astrophysics Data System (ADS)

    Ramirez-Gutierrez, C. F.; Castaño-Yepes, J. D.; Rodriguez-García, M. E.

    2016-05-01

    There are a few methodologies for monitoring the in-situ formation of Porous Silicon (PS). One of the methodologies is photoacoustic. Previous works that reported the use of photoacoustic to study the PS formation do not provide the physical explanation of the origin of the signal. In this paper, a physical explanation of the origin of the photoacoustic signal during the PS etching is provided. The incident modulated radiation and changes in the reflectance are taken as thermal sources. In this paper, a useful methodology is proposed to determine the etching rate, porosity, and refractive index of a PS film by the determination of the sample thickness, using scanning electron microscopy images. This method was developed by carrying out two different experiments using the same anodization conditions. The first experiment consisted of growth of the samples with different etching times to prove the periodicity of the photoacoustic signal, while the second one considered the growth samples using three different wavelengths that are correlated with the period of the photoacoustic signal. The last experiment showed that the period of the photoacoustic signal is proportional to the laser wavelength.

  13. Sequim Marine Research Laboratory routine environmental measurements during CY-1977

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fix, J.J.; Blumer, P.J.

    1978-06-01

    Beginning in 1976, a routine environmental program was established at the Marine Research Laboratory (MRL) at Sequim, Washington. The program is intended to demonstrate the negligible impact of current MRL operations on the surrounding environs and to provide baseline data through which any cumulative impact could be detected. The sampling frequency is greater during the first 2 years of the program to provide sufficient initial information to allow reliable estimates of observed radionuclide concentrations and to construct a long-term sampling program. The program is designed, primarily, to determine levels of radioactivity present in selected biota in Sequim Bay. The biotamore » were selected because of their presence near the laboratory and their capacity to concentrate trace elements. Other samples were obtained to determine the radionuclides in Sequim Bay and laboratory drinking water, as well as the ambient radiation exposure levels and surface deposition of fallout radionuclides for the laboratory area. Appendix A provides a summary of the analytical methods used. The present document includes data obtained during CY 1977 in addition to CY-1976 data published previously.« less

  14. Adaptive Optics Imaging Survey of Luminous Infrared Galaxies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laag, E A; Canalizo, G; van Breugel, W

    2006-03-13

    We present high resolution imaging observations of a sample of previously unidentified far-infrared galaxies at z < 0.3. The objects were selected by cross-correlating the IRAS Faint Source Catalog with the VLA FIRST catalog and the HST Guide Star Catalog to allow for adaptive optics observations. We found two new ULIGs (with L{sub FIR} {ge} 10{sup 12} L{sub {circle_dot}}) and 19 new LIGs (with L{sub FIR} {ge} 10{sup 11} L{sub {circle_dot}}). Twenty of the galaxies in the sample were imaged with either the Lick or Keck adaptive optics systems in H or K{prime}. Galaxy morphologies were determined using the twomore » dimensional fitting program GALFIT and the residuals examined to look for interesting structure. The morphologies reveal that at least 30% are involved in tidal interactions, with 20% being clear mergers. An additional 50% show signs of possible interaction. Line ratios were used to determine powering mechanism; of the 17 objects in the sample showing clear emission lines--four are active galactic nuclei and seven are starburst galaxies. The rest exhibit a combination of both phenomena.« less

  15. Psychophysics of remembering.

    PubMed Central

    White, K G; Wixted, J T

    1999-01-01

    We present a new model of remembering in the context of conditional discrimination. For procedures such as delayed matching to sample, the effect of the sample stimuli at the time of remembering is represented by a pair of Thurstonian (normal) distributions of effective stimulus values. The critical assumption of the model is that, based on prior experience, each effective stimulus value is associated with a ratio of reinforcers obtained for previous correct choices of the comparison stimuli. That ratio determines the choice that is made on the basis of the matching law. The standard deviations of the distributions are assumed to increase with increasing retention-interval duration, and the distance between their means is assumed to be a function of other factors that influence overall difficulty of the discrimination. It is a behavioral model in that choice is determined by its reinforcement history. The model predicts that the biasing effects of the reinforcer differential increase with decreasing discriminability and with increasing retention-interval duration. Data from several conditions using a delayed matching-to-sample procedure with pigeons support the predictions. PMID:10028693

  16. The use of the ion probe mass spectrometer in the measurement of hydrogen concentration gradients in Monel K 500

    NASA Technical Reports Server (NTRS)

    Truhan, J. J., Jr.; Hehemann, R. F.

    1974-01-01

    The ion probe mass spectrometer was used to measure hydrogen concentration gradients in cathodically charged Monel K 500. Initial work with the ion probe involved the calibration of the instrument and the establishment of a suitable experimental procedure for this application. Samples of Monel K 500 were cathodically charged in a weak sulfuric acid solution. By varying the current density, different levels of hydrogen were introduced into the samples. Hydrogen concentration gradients were taken by ion sputtering on the surface of these samples and monitoring the behavior of the hydrogen mass peak as a function of time. An attempt was made to determine the relative amounts of hydrogen in the bulk and grain boundaries by analyzing a fresh fracture surface with a higher proportion of grain boundary area. It was found that substantially more hydrogen was detected in the grain boundaries than in the bulk, confirming the predictions of previous workers. A sputter rate determination was made in order to establish the rate of erosion.

  17. Determination of pyrrolizidine alkaloids in tea, herbal drugs and honey.

    PubMed

    Bodi, Dorina; Ronczka, Stefan; Gottschalk, Christoph; Behr, Nastassja; Skibba, Anne; Wagner, Matthias; Lahrssen-Wiederholt, Monika; Preiss-Weigert, Angelika; These, Anja

    2014-01-01

    Honey was previously considered to be one of the main food sources of human pyrrolizidine alkaloid (PA) exposure in Europe. However, comprehensive analyses of honey and tea sampled in the Berlin retail market revealed unexpected high PA amounts in teas. This study comprised the analysis of 87 honey as well as 274 tea samples including black, green, rooibos, melissa, peppermint, chamomile, fennel, nettle, and mixed herbal tea or fruit tea. Total PA concentrations in tea ranged from < LOD to 5647 µg kg(-1), while a mean value of about 10 µg kg(-1) was found in honey samples. Additionally, herbal drugs were investigated to identify the source of PA in teas. Results suggest that PA in tea samples are most likely a contamination caused by co-harvesting of PA-producing plants. In some cases such as fennel, anise or caraway, it cannot be excluded that these plants are able to produce PA themselves.

  18. Chemical fractionation of Cu and Zn in stormwater, roadway dust and stormwater pond sediments

    USGS Publications Warehouse

    Camponelli, Kimberly M.; Lev, Steven M.; Snodgrass, Joel W.; Landa, Edward R.; Casey, Ryan E.

    2010-01-01

    This study evaluated the chemical fractionation of Cu and Zn from source to deposition in a stormwater system. Cu and Zn concentrations and chemical fractionation were determined for roadway dust, roadway runoff and pond sediments. Stormwater Cu and Zn concentrations were used to generate cumulative frequency distributions to characterize potential exposure to pond-dwelling organisms. Dissolved stormwater Zn exceeded USEPA acute and chronic water quality criteria in approximately 20% of storm samples and 20% of the storm duration sampled. Dissolved Cu exceeded the previously published chronic criterion in 75% of storm samples and duration and exceeded the acute criterion in 45% of samples and duration. The majority of sediment Cu (92–98%) occurred in the most recalcitrant phase, suggesting low bioavailability; Zn was substantially more available (39–62% recalcitrant). Most sediment concentrations for Cu and Zn exceeded published threshold effect concentrations and Zn often exceeded probable effect concentrations in surface sediments.

  19. Confidence Hills Mineralogy and Chemin Results from Base of Mt. Sharp, Pahrump Hills, Gale Crater, Mars

    NASA Technical Reports Server (NTRS)

    Cavanagh, P. D.; Bish, D. L.; Blake, D. F.; Vaniman, D. T.; Morris, R. V.; Ming, D. W.; Rampe, E. B.; Achilles, C. N.; Chipera, S. J.; Treiman, A. H.; hide

    2015-01-01

    The Mars Science Laboratory (MSL) rover Curiosity recently completed its fourth drill sampling of sediments on Mars. The Confidence Hills (CH) sample was drilled from a rock located in the Pahrump Hills region at the base of Mt. Sharp in Gale Crater. The CheMin X-ray diffractometer completed five nights of analysis on the sample, more than previously executed for a drill sample, and the data have been analyzed using Rietveld refinement and full-pattern fitting to determine quantitative mineralogy. Confidence Hills mineralogy has several important characteristics: 1) abundant hematite and lesser magnetite; 2) a 10 angstrom phyllosilicate; 3) multiple feldspars including plagioclase and alkali feldspar; 4) mafic silicates including forsterite, orthopyroxene, and two types of clinopyroxene (Ca-rich and Ca-poor), consistent with a basaltic source; and 5) minor contributions from sulfur-bearing species including jarosite.

  20. Beryllium 7 and lead 210 in the Western Hemisphere Arctic atmosphere - Observations from three recent aircraft-based sampling programs

    NASA Technical Reports Server (NTRS)

    Dibb, Jack E.; Talbot, Robert W.; Gregory, Gerald L.

    1992-01-01

    Concentrations of the natural radionuclides Be-7 and Pb-210 in the Western Hemisphere Arctic atmosphere were determined during the recent NOAA Arctic Gas and Aerosol Sampling Program (AGASP 3) and NASA Global Tropospheric Experiment/Arctic Boundary Layer Expeditions (GTE/ABLE 3A and ABLE 3B) missions. Be-7 concentrations measured during the AGASP 3 mission north and west of Norway are in accord with previous results for high northern latitudes, but suggest that the 'stratospheric' air masses sampled at the highest elevations reached were significantly diluted with tropospheric air. Higher resolution sampling in the free troposphere of the North American Arctic during ABLE 3B revealed a layer of elevated Be-7 concentrations near 5 km. The distribution of Pb-210 in the high-altitude troposphere of North America during the summer was quite similar to distributions of more frequently measured aerosol species.

  1. Small-angle X-ray scattering tensor tomography: model of the three-dimensional reciprocal-space map, reconstruction algorithm and angular sampling requirements.

    PubMed

    Liebi, Marianne; Georgiadis, Marios; Kohlbrecher, Joachim; Holler, Mirko; Raabe, Jörg; Usov, Ivan; Menzel, Andreas; Schneider, Philipp; Bunk, Oliver; Guizar-Sicairos, Manuel

    2018-01-01

    Small-angle X-ray scattering tensor tomography, which allows reconstruction of the local three-dimensional reciprocal-space map within a three-dimensional sample as introduced by Liebi et al. [Nature (2015), 527, 349-352], is described in more detail with regard to the mathematical framework and the optimization algorithm. For the case of trabecular bone samples from vertebrae it is shown that the model of the three-dimensional reciprocal-space map using spherical harmonics can adequately describe the measured data. The method enables the determination of nanostructure orientation and degree of orientation as demonstrated previously in a single momentum transfer q range. This article presents a reconstruction of the complete reciprocal-space map for the case of bone over extended ranges of q. In addition, it is shown that uniform angular sampling and advanced regularization strategies help to reduce the amount of data required.

  2. Motivational and emotional profiles in university undergraduates: a self-determination theory perspective.

    PubMed

    González, Antonio; Paoloni, Verónica; Donolo, Danilo; Rinaudo, Cristina

    2012-11-01

    Previous research has focused on specific forms of self-determined motivation or discrete class-related emotions, but few studies have simultaneously examined both constructs. The aim of this study on 472 undergraduates was twofold: to perform cluster analysis to identify homogeneous groups of motivation in the sample; and to determine the profile of each cluster for emotions and academic achievement. Cluster analysis configured four groups in terms of motivation: controlled, autonomous, both high, and both low. Each cluster revealed a distinct emotional profile, autonomous motivation being the most adaptable with high scores for academic achievement and pleasant emotions and low values for unpleasant emotions. The results are discussed in the light of their implications for academic adjustment.

  3. Bomb-Pulse Chlorine-36 At The Proposed Yucca Mountain Repository Horizon: An Investigation Of Previous Conflicting Results And Collection Of New Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Cizdziel

    2006-07-28

    Previous studies by scientists at Los Alamos National Laboratory (LANL) found elevated ratios of chlorine-36 to total chloride ({sup 36}Cl/Cl) in samples of rock collected from the Exploratory Studies Facility (ESF) and the Enhanced Characterization of the Repository Block (ECRB) at Yucca Mountain as the tunnels were excavated. The data were interpreted as an indication that fluids containing 'bomb-pulse' {sup 36}Cl reached the repository horizon in the {approx}50 years since the peak period of above-ground nuclear testing. Moreover, the data support the concept that so-called fast pathways for infiltration not only exist but are active, possibly through a combination ofmore » porous media, faults and/or other geologic features. Due to the significance of {sup 36}Cl data to conceptual models of unsaturated zone flow and transport, the United States Geological Survey (USGS) was requested by the Department of Energy (DOE) to design and implement a study to validate the LANL findings. The USGS chose to drill new boreholes at select locations across zones where bomb-pulse ratios had previously been identified. The drill cores were analyzed at Lawrence Livermore National Laboratory (LLNL) for {sup 36}Cl/Cl using both active and passive leaches, with the USGS/LLNL concluding that the active leach extracted too much rock-Cl and the passive leach did not show bomb-pulse ratios. Because consensus was not reached between the USGS/LLNL and LANL on several fundamental points, including the conceptual strategy for sampling, interpretation and use of tritium ({sup 3}H) data, and the importance and interpretation of blanks, in addition to the presence or absence of bomb-pulse {sup 36}Cl, an evaluation by an independent entity, the University of Nevada, Las Vegas (UNLV), using new samples was initiated. This report is the result of that study. The overall objectives of the UNLV study were to investigate the source or sources of the conflicting results from the previous validation study, and to obtain additional data to determine whether or not there are bomb-pulse isotopes at the repository horizon. To that en4 we have engaged in discussions with previous investigators, reviewed reports, and analyzed archived samples. We have also collected new samples of rock from the ESF, soil profiles from the surface of Yucca Mountain, and opportunistic samples of seep water from inside the south ramp of the ESF.« less

  4. No Associations between Interindividual Differences in Sleep Parameters and Episodic Memory Consolidation.

    PubMed

    Ackermann, Sandra; Hartmann, Francina; Papassotiropoulos, Andreas; de Quervain, Dominique J-F; Rasch, Björn

    2015-06-01

    Sleep and memory are stable and heritable traits that strongly differ between individuals. Sleep benefits memory consolidation, and the amount of slow wave sleep, sleep spindles, and rapid eye movement sleep have been repeatedly identified as reliable predictors for the amount of declarative and/or emotional memories retrieved after a consolidation period filled with sleep. These studies typically encompass small sample sizes, increasing the probability of overestimating the real association strength. In a large sample we tested whether individual differences in sleep are predictive for individual differences in memory for emotional and neutral pictures. Between-subject design. Cognitive testing took place at the University of Basel, Switzerland. Sleep was recorded at participants' homes, using portable electroencephalograph-recording devices. Nine hundred-twenty-nine healthy young participants (mean age 22.48 ± 3.60 y standard deviation). None. In striking contrast to our expectations as well as numerous previous findings, we did not find any significant correlations between sleep and memory consolidation for pictorial stimuli. Our results indicate that individual differences in sleep are much less predictive for pictorial memory processes than previously assumed and suggest that previous studies using small sample sizes might have overestimated the association strength between sleep stage duration and pictorial memory performance. Future studies need to determine whether intraindividual differences rather than interindividual differences in sleep stage duration might be more predictive for the consolidation of emotional and neutral pictures during sleep. © 2015 Associated Professional Sleep Societies, LLC.

  5. Determination of bisphenol A in thermal printing papers treated by alkaline aqueous solution using the combination of single-drop microextraction and HPLC.

    PubMed

    Gao, Leihong; Zou, Jing; Liu, Haihong; Zeng, Jingbin; Wang, Yiru; Chen, Xi

    2013-04-01

    A method for the quantitative determination of bisphenol A in thermal printing paper was developed and validated. Bisphenol A was extracted from the paper samples using 2% NaOH solution, then the extracted analyte was enriched using single-drop microextraction followed by HPLC analysis. Several parameters relating to the single-drop microextraction efficiency including extraction solvent, extraction temperature and time, stirring rate, and pH of donor phase were studied and optimized. Spiked recovery of bisphenol A at 20 and 5 mg/g was found to be 95.8 and 108%, and the method detection limit and method quantification limit was 0.03 and 0.01 mg/g, respectively. Under the optimized conditions, the proposed method was applied to the determination of bisphenol A in seven types of thermal printing paper samples, and the concentration of bisphenol A was found in the range of 0.53-20.9 mg/g. The considerably minimum usage of organic solvents (5 μL 1-octanol) and high enrichment factor (189-197) in the sample preparation are the two highlighted advantages in comparison with previously published works. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Towards the feasibility of using ultrasound to determine mechanical properties of tissues in a bioreactor.

    PubMed

    Mansour, Joseph M; Gu, Di-Win Marine; Chung, Chen-Yuan; Heebner, Joseph; Althans, Jake; Abdalian, Sarah; Schluchter, Mark D; Liu, Yiying; Welter, Jean F

    2014-10-01

    Our ultimate goal is to non-destructively evaluate mechanical properties of tissue-engineered (TE) cartilage using ultrasound (US). We used agarose gels as surrogates for TE cartilage. Previously, we showed that mechanical properties measured using conventional methods were related to those measured using US, which suggested a way to non-destructively predict mechanical properties of samples with known volume fractions. In this study, we sought to determine whether the mechanical properties of samples, with unknown volume fractions could be predicted by US. Aggregate moduli were calculated for hydrogels as a function of SOS, based on concentration and density using a poroelastic model. The data were used to train a statistical model, which we then used to predict volume fractions and mechanical properties of unknown samples. Young's and storage moduli were measured mechanically. The statistical model generally predicted the Young's moduli in compression to within <10% of their mechanically measured value. We defined positive linear correlations between the aggregate modulus predicted from US and both the storage and Young's moduli determined from mechanical tests. Mechanical properties of hydrogels with unknown volume fractions can be predicted successfully from US measurements. This method has the potential to predict mechanical properties of TE cartilage non-destructively in a bioreactor.

  7. Towards the feasibility of using ultrasound to determine mechanical properties of tissues in a bioreactor

    PubMed Central

    Mansour, Joseph M.; Gu, Di-Win Marine; Chung, Chen-Yuan; Heebner, Joseph; Althans, Jake; Abdalian, Sarah; Schluchter, Mark D.; Liu, Yiying; Welter, Jean F.

    2016-01-01

    Introduction Our ultimate goal is to non-destructively evaluate mechanical properties of tissue-engineered (TE) cartilage using ultrasound (US). We used agarose gels as surrogates for TE cartilage. Previously, we showed that mechanical properties measured using conventional methods were related to those measured using US, which suggested a way to non-destructively predict mechanical properties of samples with known volume fractions. In this study, we sought to determine whether the mechanical properties of samples, with unknown volume fractions could be predicted by US. Methods Aggregate moduli were calculated for hydrogels as a function of SOS, based on concentration and density using a poroelastic model. The data were used to train a statistical model, which we then used to predict volume fractions and mechanical properties of unknown samples. Young's and storage moduli were measured mechanically. Results The statistical model generally predicted the Young's moduli in compression to within < 10% of their mechanically measured value. We defined positive linear correlations between the aggregate modulus predicted from US and both the storage and Young's moduli determined from mechanical tests. Conclusions Mechanical properties of hydrogels with unknown volume fractions can be predicted successfully from US measurements. This method has the potential to predict mechanical properties of TE cartilage non-destructively in a bioreactor. PMID:25092421

  8. Optical molecular fluorescence determination of ultra-trace beryllium in occupational and environmental samples using highly alkaline conditions.

    PubMed

    Adams, Lori; Agrawal, Anoop; Cronin, John P; Ashley, Kevin

    2017-01-01

    Exposures to beryllium (Be), even at extremely low levels, can cause severe health effects in a percentage of those exposed; consequently, occupational exposure limits (OELs) promulgated for this element are the lowest established for any element. This work describes the advantages of using highly alkaline dye solutions for determination of Be in occupational hygiene and environmental samples by means of an optical molecular fluorescence technique after sample extraction in 1-3% (w˖w -1 ) aqueous ammonium bifluoride (NH 4 HF 2 ). Improved attributes include the ability to further enhance the detection limits of Be in extraction solutions of high acidity with minimal dilution, which is particularly beneficial when NH 4 HF 2 solutions of higher concentration are used for extraction of Be from soil samples. Significant improvements in Be method detection limits (MDLs) are obtained at levels many-fold below those reported previously for this methodology. Notably, MDLs for Be of <0.01 ng l -1 / 0.1 ng per sample have been attained, which are superior to MDLs routinely reported for this element by means of the most widely used ultra-trace elemental measurement technique, inductively coupled plasma mass spectrometry (ICP-MS). Very low MDLs for Be are essential in consideration of reductions in OELs for this element in workplace air by health organizations and regulatory agencies in the USA and internationally. Applications of enhanced Be measurements to air filter samples, surface wipe samples, soils and newly-designed occupational air sampler inserts are illustrated.

  9. Thermal conductivity measurements of particulate materials: 3. Natural samples and mixtures of particle sizes

    NASA Astrophysics Data System (ADS)

    Presley, Marsha A.; Craddock, Robert A.

    2006-09-01

    A line-heat source apparatus was used to measure thermal conductivities of natural fluvial and eolian particulate sediments under low pressures of a carbon dioxide atmosphere. These measurements were compared to a previous compilation of the dependence of thermal conductivity on particle size to determine a thermal conductivity-derived particle size for each sample. Actual particle-size distributions were determined via physical separation through brass sieves. Comparison of the two analyses indicates that the thermal conductivity reflects the larger particles within the samples. In each sample at least 85-95% of the particles by weight are smaller than or equal to the thermal conductivity-derived particle size. At atmospheric pressures less than about 2-3 torr, samples that contain a large amount of small particles (<=125 μm or 4 Φ) exhibit lower thermal conductivities relative to those for the larger particles within the sample. Nonetheless, 90% of the sample by weight still consists of particles that are smaller than or equal to this lower thermal conductivity-derived particle size. These results allow further refinement in the interpretation of geomorphologic processes acting on the Martian surface. High-energy fluvial environments should produce poorer-sorted and coarser-grained deposits than lower energy eolian environments. Hence these results will provide additional information that may help identify coarser-grained fluvial deposits and may help differentiate whether channel dunes are original fluvial sediments that are at most reworked by wind or whether they represent a later overprint of sediment with a separate origin.

  10. Work disability and depressive disorders: impact on the European population.

    PubMed

    Veronese, Antonio; Ayuso-Mateos, José Luis; Cabello, Maria; Chatterji, Somnath; Nuevo, Roberto

    2012-02-01

    Our aim was to study the impact of depressive disorders on work disability to discover the determinants of depression for work disability in the European countries. The sample was composed of 31,126 individuals from 29 countries included in the 2002 World Health Survey of the World Health Organization. National representative samples of countries from all regions of Europe and with different levels of economic development and health coverage were selected. Estimates of people not working because of ill health did not differ among European countries in relation to levels of economic development or health coverage. Significant determinants of people with diagnosis of depression not working because of ill health (reference category) versus working were age (odds ratio = 0.97), female sex (odds ratio = 1.71), education (odds ratio = 1.11), marital status (being unmarried indicating less probability), lowest income level, and comorbidity with angina pectoris (odds ratio = 0.51). Moreover, according to previous studies, we found some determinants (comorbidity with other diseases, young age, and unemployment) impacting on health status. Depression is a substantial cause of work disability and it is a complex phenomenon that involves many variables. Investigation into this relationship should improve, focusing on the role of determinants.

  11. High Concentrations of Angiopoietin-Like Protein 4 Detected in Serum from Patients with Rheumatoid Arthritis Can Be Explained by Non-Specific Antibody Reactivity.

    PubMed

    Makoveichuk, Elena; Ruge, Toralph; Nilsson, Solveig; Södergren, Anna; Olivecrona, Gunilla

    2017-01-01

    Angiopoietin-like protein 4 (ANGPTL4) is suggested to be a master regulator of plasma triglyceride metabolism. Our aim was to study whether the previously reported high levels of ANGPTL4 detected in serum from patients with rheumatoid arthritis (RA) by ELISA was due to any specific molecular form of this protein (oligomers, monomers or fragments). ANGPTL4 levels were first determined in serum from 68 RA patients and 43 age and sex matched control subjects and the mean values differed by a factor of 5.0. Then, ANGPTL4 was analyzed after size exclusion chromatography (SEC) of serum samples. With serum from one of the RA patients with high levels of ANGPTL4, the dominant reactivity was found in fractions corresponding to high-molecular weight proteins. In addition, a minor peak of reactivity eluting late from the column was found both in the patient and in controls. By the use of HeteroBlock®, and by careful selection of antibodies, we documented non-specific reactions for ANGPTL4 in 39% of samples from the RA patients, most likely due to cross-reactivity of the antibodies with rheumatoid factor (RF). The corresponding figure for control subjects was 6.3%. After corrections for non-specific reactions, the mean level of ANGPTL4 in serum from RA patients was still significantly higher than in control individuals (mean levels were 101±62 and 67±39 ng/ml respectively, P = 0.02). We re-analyzed samples from our previously published studies on ANGPL4 levels in patients on hemodialysis and patients with diabetes type 2. These samples did not show false positive reactions. The levels of ANGPTL4 were comparable to those detected previously.

  12. Cognitive determinants of cervical cancer screening behavior among housewife women in Iran: An application of Health Belief Model.

    PubMed

    Babazadeh, Towhid; Nadrian, Haidar; Rezakhani Moghaddam, Hamed; Ezzati, Elaheh; Sarkhosh, Reza; Aghemiri, Shahin

    2018-05-01

    Our aim in this cross-sectional study was to assess the cognitive determinants of Cervical Cancer Screening Behavior (CCSB) among housewife women in Islamabad County, Iran. Through multistage random sampling we recruited and interviewed 280 housewife women. The women who perceived more benefits of performing the Pap test (OR = 1.11), and perceived fewer barriers (OR = 0.915), and higher self-efficacy to perform the test (OR = 1.12) were more likely to have a CCSB in the previous three years. Our findings are informative for the development of targeted interventions to foster CCSB among housewife women.

  13. Solubility Control of Technetium Release from Saltstone by Tc02•xH20

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantrell, Kirk J.; Williams, Benjamin D.

    2013-11-12

    Saltstone leaching experiments were conducted using a modified single-pass flow-through method under anoxic conditions. The analytical results of leachates collected from these experiments were evaluated using thermodynamic modeling to determine if the data were consistent with potential solubility controlling phases. The results demonstrate that technetium concentrations in water in contact with Saltstone under anoxic conditions is controlled by the solubility of TcO2•xH2O (likely TcO2•1.6H2O). In our system equilibrium solubility appears to have been reached within two weeks at a concentration of approximately 1.5 x 10-6 M. This concentration is likely to vary as the composition of Saltstone pore fluid evolvesmore » over time. As the pH goes from the initial high values (~12.5-13) to lower values, the solubility of technetium will decrease significantly. The thermodynamic data used to determine the solubility of TcO2•1.6H2O were taken from the tabulation of critically selected thermodynamic data determined by the Nuclear Energy Agency. Solid phase characterization to demonstrate the presence of TcO2•xH2O was not possible due to the low concentrations of technetium in our samples. Previous solid phase characterization studies with cementitious waste forms that were very similar to our Saltstone samples as well as reaction products derived from reductive immobilization of TcO4- by amorphous FeS clearly indicate the presence of TcO2 with varying degrees of hydration. Although, the presence of TcSx or other reduced technetium sulfide phases in our samples cannot be ruled out, release of technetium from Saltstone will be controlled by TcO2•1.6H2O because of its higher solubility. Our results clearly demonstrate that the release mechanism of technetium from Saltstone under reducing conditions is solubility controlled by TcO2•xH2O (likely TcO2•1.6H2O); however, distribution coefficients (Kds), that describe sorption and not solubility, were calculated for comparison with past literature values. After 84 days of reaction under anoxic conditions, the average Kd value for technetium was determined to be 610 mL/g. This value is similar to a value determined previously for a similar saltstone sample under reducing conditions at 56 days (712 ± 81 mL/g).« less

  14. Calorimetric system and method

    DOEpatents

    Gschneidner, K.A. Jr.; Pecharsky, V.K.; Moorman, J.O.

    1998-09-15

    Apparatus is described for measuring heat capacity of a sample where a series of measurements are taken in succession comprises a sample holder in which a sample to be measured is disposed, a temperature sensor and sample heater for providing a heat pulse thermally connected to the sample, and an adiabatic heat shield in which the sample holder is positioned and including an electrical heater. An electrical power supply device provides an electrical power output to the sample heater to generate a heat pulse. The electrical power from a power source to the heat shield heater is adjusted by a control device, if necessary, from one measurement to the next in response to a sample temperature-versus-time change determined before and after a previous heat pulse to provide a subsequent sample temperature-versus-time change that is substantially linear before and after the subsequent heat pulse. A temperature sensor is used and operable over a range of temperatures ranging from approximately 3K to 350K depending upon the refrigerant used. The sample optionally can be subjected to dc magnetic fields such as from 0 to 12 Tesla (0 to 120 kOe). 18 figs.

  15. Revisiting chlorophyll extraction methods in biological soil crusts - methodology for determination of chlorophyll a and chlorophyll a + b as compared to previous methods

    NASA Astrophysics Data System (ADS)

    Caesar, Jennifer; Tamm, Alexandra; Ruckteschler, Nina; Lena Leifke, Anna; Weber, Bettina

    2018-03-01

    Chlorophyll concentrations of biological soil crust (biocrust) samples are commonly determined to quantify the relevance of photosynthetically active organisms within these surface soil communities. Whereas chlorophyll extraction methods for freshwater algae and leaf tissues of vascular plants are well established, there is still some uncertainty regarding the optimal extraction method for biocrusts, where organism composition is highly variable and samples comprise major amounts of soil. In this study we analyzed the efficiency of two different chlorophyll extraction solvents, the effect of grinding the soil samples prior to the extraction procedure, and the impact of shaking as an intermediate step during extraction. The analyses were conducted on four different types of biocrusts. Our results show that for all biocrust types chlorophyll contents obtained with ethanol were significantly lower than those obtained using dimethyl sulfoxide (DMSO) as a solvent. Grinding of biocrust samples prior to analysis caused a highly significant decrease in chlorophyll content for green algal lichen- and cyanolichen-dominated biocrusts, and a tendency towards lower values for moss- and algae-dominated biocrusts. Shaking of the samples after each extraction step had a significant positive effect on the chlorophyll content of green algal lichen- and cyanolichen-dominated biocrusts. Based on our results we confirm a DMSO-based chlorophyll extraction method without grinding pretreatment and suggest the addition of an intermediate shaking step for complete chlorophyll extraction (see Supplement S6 for detailed manual). Determination of a universal chlorophyll extraction method for biocrusts is essential for the inter-comparability of publications conducted across all continents.

  16. Simultaneous speciation of arsenic, selenium, and chromium: Species stability, sample preservation, and analysis of ash and soil leachates

    USGS Publications Warehouse

    Wolf, R.E.; Morman, S.A.; Hageman, P.L.; Hoefen, T.M.; Plumlee, G.S.

    2011-01-01

    An analytical method using high-performance liquid chromatography separation with inductively coupled plasma mass spectrometry (ICP-MS) detection previously developed for the determination of Cr(III) and Cr(VI) has been adapted to allow the determination of As(III), As(V), Se(IV), Se(VI), Cr(III), and Cr(VI) under the same chromatographic conditions. Using this method, all six inorganic species can be determined in less than 3 min. A dynamic reaction cell (DRC)-ICP-MS system was used to detect the species eluted from the chromatographic column in order to reduce interferences. A variety of reaction cell gases and conditions may be utilized with the DRC-ICP-MS, and final selection of conditions is determined by data quality objectives. Results indicated all starting standards, reagents, and sample vials should be thoroughly tested for contamination. Tests on species stability indicated that refrigeration at 10 ??C was preferential to freezing for most species, particularly when all species were present, and that sample solutions and extracts should be analyzed as soon as possible to eliminate species instability and interconversion effects. A variety of environmental and geological samples, including waters and deionized water [leachates] and simulated biological leachates from soils and wildfire ashes have been analyzed using this method. Analytical spikes performed on each sample were used to evaluate data quality. Speciation analyses were conducted on deionized water leachates and simulated lung fluid leachates of ash and soils impacted by wildfires. These results show that, for leachates containing high levels of total Cr, the majority of the chromium was present in the hexavalent Cr(VI) form. In general, total and hexavalent chromium levels for samples taken from burned residential areas were higher than those obtained from non-residential forested areas. Arsenic, when found, was generally in the more oxidized As(V) form. Selenium (IV) and (VI) were present, but typically at low levels. ?? 2011 Springer-Verlag (outside the USA).

  17. Simultaneous speciation of arsenic, selenium, and chromium: species, stability, sample preservation, and analysis of ash and soil leachates

    USGS Publications Warehouse

    Wolf, Ruth E.; Morman, Suzette A.; Hageman, Philip L.; Hoefen, Todd M.; Plumlee, Geoffrey S.

    2011-01-01

    An analytical method using high-performance liquid chromatography separation with inductively coupled plasma mass spectrometry (ICP-MS) detection previously developed for the determination of Cr(III) and Cr(VI) has been adapted to allow the determination of As(III), As(V), Se(IV), Se(VI), Cr(III), and Cr(VI) under the same chromatographic conditions. Using this method, all six inorganic species can be determined in less than 3 min. A dynamic reaction cell (DRC)-ICP-MS system was used to detect the species eluted from the chromatographic column in order to reduce interferences. A variety of reaction cell gases and conditions may be utilized with the DRC-ICP-MS, and final selection of conditions is determined by data quality objectives. Results indicated all starting standards, reagents, and sample vials should be thoroughly tested for contamination. Tests on species stability indicated that refrigeration at 10° C was preferential to freezing for most species, particularly when all species were present, and that sample solutions and extracts should be analyzed as soon as possible to eliminate species instability and interconversion effects. A variety of environmental and geological samples, including waters and deionized water [leachates] and simulated biological leachates from soils and wildfire ashes have been analyzed using this method. Analytical spikes performed on each sample were used to evaluate data quality. Speciation analyses were conducted on deionized water leachates and simulated lung fluid leachates of ash and soils impacted by wildfires. These results show that, for leachates containing high levels of total Cr, the majority of the chromium was present in the hexavalent Cr(VI) form. In general, total and hexavalent chromium levels for samples taken from burned residential areas were higher than those obtained from non-residential forested areas. Arsenic, when found, was generally in the more oxidized As(V) form. Selenium (IV) and (VI) were present, but typically at low levels.

  18. Further studies on the problems of geomagnetic field intensity determination from archaeological baked clay materials

    NASA Astrophysics Data System (ADS)

    Kostadinova-Avramova, M.; Kovacheva, M.

    2015-10-01

    Archaeological baked clay remains provide valuable information about the geomagnetic field in historical past, but determination of the geomagnetic field characteristics, especially intensity, is often a difficult task. This study was undertaken to elucidate the reasons for unsuccessful intensity determination experiments obtained from two different Bulgarian archaeological sites (Nessebar - Early Byzantine period and Malenovo - Early Iron Age). With this aim, artificial clay samples were formed in the laboratory and investigated. The clay used for the artificial samples preparation differs according to its initial state. Nessebar clay was baked in the antiquity, but Malenovo clay was raw, taken from the clay deposit near the site. The obtained artificial samples were repeatedly heated eight times in known magnetic field to 700 °C. X-ray diffraction analyses and rock-magnetic experiments were performed to obtain information about the mineralogical content and magnetic properties of the initial and laboratory heated clays. Two different protocols were applied for the intensity determination-Coe version of Thellier and Thellier method and multispecimen parallel differential pTRM protocol. Various combinations of laboratory fields and mutual positions of the directions of laboratory field and carried thermoremanence were used in the performed Coe experiment. The obtained results indicate that the failure of this experiment is probably related to unfavourable grain sizes of the prevailing magnetic carriers combined with the chosen experimental conditions. The multispecimen parallel differential pTRM protocol in its original form gives excellent results for the artificial samples, but failed for the real samples (samples coming from previously studied kilns of Nessebar and Malenovo sites). Obviously the strong dependence of this method on the homogeneity of the used subsamples hinders its implementation in its original form for archaeomaterials. The latter are often heterogeneous due to variable heating conditions in the different parts of the archaeological structures. The study draws attention to the importance of multiple heating for the stabilization of grain size distribution in baked clay materials and the need of elucidation of this question.

  19. Colorimetric-Solid Phase Extraction Technology for Water Quality Monitoring: Evaluation of C-SPE and Debubbling Methods in Microgravity

    NASA Technical Reports Server (NTRS)

    Hazen-Bosveld, April; Lipert, Robert J.; Nordling, John; Shih, Chien-Ju; Siperko, Lorraine; Porter, Marc D.; Gazda, Daniel B.; Rutz, Jeff A.; Straub, John E.; Schultz, John R.; hide

    2007-01-01

    Colorimetric-solid phase extraction (C-SPE) is being developed as a method for in-flight monitoring of spacecraft water quality. C-SPE is based on measuring the change in the diffuse reflectance spectrum of indicator disks following exposure to a water sample. Previous microgravity testing has shown that air bubbles suspended in water samples can cause uncertainty in the volume of liquid passed through the disks, leading to errors in the determination of water quality parameter concentrations. We report here the results of a recent series of C-9 microgravity experiments designed to evaluate manual manipulation as a means to collect bubble-free water samples of specified volumes from water sample bags containing up to 47% air. The effectiveness of manual manipulation was verified by comparing the results from C-SPE analyses of silver(I) and iodine performed in-flight using samples collected and debubbled in microgravity to those performed on-ground using bubble-free samples. The ground and flight results showed excellent agreement, demonstrating that manual manipulation is an effective means for collecting bubble-free water samples in microgravity.

  20. Socio-demographic and work-related risk factors for medium- and long-term sickness absence among Italian workers.

    PubMed

    d'Errico, Angelo; Costa, Giuseppe

    2012-10-01

    Few studies investigated determinants of sickness absence in representative samples of the general population, none of which in Italy. Aim of this study was to assess influence and relative importance of socio-demographic and work-related characteristics on medium- and long-term sickness absence in a random sample of Italian workers. Approximately 60,000 workers participating in a national survey in 2007 were interviewed regarding sickness absence during the whole previous week, and on socio-demographics, employment characteristics and exposure to a set of physical and psychosocial hazards in the workplace. The association between sickness absence and potential determinants was estimated by multivariable logistic regression models stratified by gender. From the final multivariate models, in both genders sickness absence was statistically significantly associated with tenure employment, working in larger firms, exposure to risk of injury and to bullying or discrimination and, among employees, with shift work. In males, sickness absence was also associated with lower education, employment in the public administration and with exposure to noise or vibration, whereas among women also with manual work and ergonomic factors. In both genders, the attributable fraction for employment-related characteristics was higher than that for socio-demographic ones. The association with tenure or salaried jobs, and with employment in larger firms or in the public sector suggests that, besides illness, job security is the most important determinant of sickness absence, consistently with the results of previous studies. However, our results indicate that a reduction in exposure to workplace hazards may contribute to reduce absenteeism.

  1. Development of a Multi-Point Quantitation Method to Simultaneously Measure Enzymatic and Structural Components of the Clostridium thermocellum Cellulosome Protein Complex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dykstra, Andrew B; St. Brice, Lois; Rodriguez, Jr., Miguel

    2014-01-01

    Clostridium thermocellum has emerged as a leading bioenergy-relevant microbe due to its ability to solubilize cellulose into carbohydrates, mediated by multi-component membrane-attached complexes termed cellulosomes. To probe microbial cellulose utilization rates, it is desirable to be able to measure the concentrations of saccharolytic enzymes and estimate the total amount of cellulosome present on a mass basis. Current cellulase determination methodologies involve labor-intensive purification procedures and only allow for indirect determination of abundance. We have developed a method using multiple reaction monitoring (MRM-MS) to simultaneously quantitate both enzymatic and structural components of the cellulosome protein complex in samples ranging in complexitymore » from purified cellulosomes to whole cell lysates, as an alternative to a previously-developed enzyme-linked immunosorbent assay (ELISA) method of cellulosome quantitation. The precision of the cellulosome mass concentration in technical replicates is better than 5% relative standard deviation for all samples, indicating high precision for determination of the mass concentration of cellulosome components.« less

  2. A flow calorimeter for determining combustion efficiency from residual enthalpy of exhaust gases

    NASA Technical Reports Server (NTRS)

    Evans, Albert; Hibbard, Robert R

    1954-01-01

    A flow calorimeter for determining the combustion efficiency of turbojet and ram-jet combustors from measurement of the residual enthalpy of combustion of the exhaust gas is described. Briefly, the calorimeter catalytically oxidizes the combustible constituents of exhaust-gas samples, and the resultant temperature rise is measured. This temperature rise is related to the residual enthalpy of combustion of the sample by previous calibration of the calorimeter. Combustion efficiency can be calculated from a knowledge of the residual enthalpy of the exhaust gas and the combustor input enthalpy. An accuracy of +-0.2 Btu per cubic foot was obtained with prepared fuel-air mixtures, and the combustion efficiencies of single turbojet combustors measured by both the flow-calorimeter and heat-balance methods compared within 3 percentage units. Flow calorimetry appears to be a suitable method for determining combustion efficiencies at high combustor temperatures where ordinary thermocouples cannot be used. The method is fundamentally more accurate than heat-balance methods at high combustion efficiencies and can be used to verify near-100-percent efficiency data.

  3. Liquid chromatographic determination of urinary 5-methyl-2'-deoxycytidine and pseudouridine as potential biological markers for leukaemia.

    PubMed

    Zambonin, C G; Aresta, A; Palmisano, F; Specchia, G; Liso, V

    1999-12-01

    A simple reversed-phase liquid chromatographic (LC) method for the determination of urinary 5-methyl-2'-deoxycytidine (m5dCyd), recently claimed (on the basis of an imuno-technique) to be a potential marker for leukaemia, has been developed. Sample pre-treatment is based on a microcolumn clean-up step with an average recovery of 79% and a RSD of 3%. Detection limit was 0.2 microg/ml which is about tenfold lower than levels previously measured by an ELISA method in urine of healthy individuals. The creatinine (Cre) excretion, necessary for normalising the m5dCyd excretion, was evaluated by ion-pair liquid chromatography which permitted the simultaneous determination of pseudouridine (psi), a modified nucleoside also potentially useful as a marker for leukaemia. The described LC procedures were applied to the analysis of urine samples from healthy individuals and leukaemia patients. While the urinary psi/Cre ratio was found significantly increased for leukaemia patients, the urinary m5dCyd levels in healthy individuals were below the detection limits and did not increase in presence of the malignant disease.

  4. Determination of chloramphenicol residues in milk, eggs, and tissues by liquid chromatography/mass spectrometry.

    PubMed

    Penney, Lisa; Smith, Anderson; Coates, Brent; Wijewickreme, Arosha

    2005-01-01

    A new liquid chromatography/mass spectrometry (LC/MS) method is presented for the determination of chloramphenicol (CAP) residues in milk, eggs, chicken muscle and liver, and beef muscle and kidney. CAP is extracted from the samples with acetonitrile and defatted with hexane. The acetonitrile extracts are then evaporated, and residues are reconstituted in 10mM ammonium acetate--acetonitrile mobile phase and injected into the LC system. CAP is determined by reversed-phase chromatography using an Inertsil ODS-2 column and MS detection with negative ion electrospray ionization. Calibration curves were linear between 0.5-5.0 ng/g for all matrixes studied. The relative standard deviations for measurements by this method were generally <12%, and average recoveries ranged from 80 to 120%, depending on the matrix involved. The method detection limits of CAP ranged from 0.2 to 0.6 ng/g, which are comparable to previously reported results. The proposed method is rapid, simple, and specific, allowing a single analyst to easily prepare over 40 samples in a regular working day.

  5. Chemical Compositions of Kinematically Selected Outer Halo Stars

    NASA Astrophysics Data System (ADS)

    Zhang, Lan; Ishigaki, Miho; Aoki, Wako; Zhao, Gang; Chiba, Masashi

    2009-12-01

    Chemical abundances of 26 metal-poor dwarfs and giants are determined from high-resolution and high signal-to-noise ratio spectra obtained with the Subaru/High Dispersion Spectrograph. The sample is selected so that most of the objects have outer-halo kinematics. Self-consistent atmospheric parameters were determined by an iterative procedure based on spectroscopic analysis. Abundances of 13 elements, including α-elements (Mg, Si, Ca, Ti), odd-Z light elements (Na, Sc), iron-peak elements (Cr, Mn, Fe, Ni, Zn), and neutron-capture elements (Y, Ba), are determined by two independent data reduction and local thermodynamic equillibrium analysis procedures, confirming the consistency of the stellar parameters and abundances results. We find a decreasing trend of [α/Fe] with increasing [Fe/H] for the range of -3.5< [Fe/H] <-1, as found by Stephens & Boesgaard. [Zn/Fe] values of most objects in our sample are slightly lower than the bulk of halo stars previously studied. These results are discussed as possible chemical properties of the outer halo in the Galaxy. Based on data collected at the Subaru Telescope, which is operated by the National Astronomical Observatory of Japan.

  6. Viscoelastic properties of three vocal-fold injectable biomaterials at low audio frequencies.

    PubMed

    Klemuk, Sarah A; Titze, Ingo R

    2004-09-01

    Previous measurements of viscoelastic properties of Zyderm were to be extended to low audio frequencies, and properties of two other biomaterials not previously measured, thiolated hyaluronic acid (HA-DTPH) and Cymetra, were obtained. Rheologic investigation. Oscillatory shear stress was applied to each sample using a controlled stress rheometer at frequencies between 0.01 and 100 Hz with a parallel plate apparatus. Versuscoelastic moduli were recorded at each frequency. The calculated resonance frequency of the machine and sample were then used to determine the maximum frequency at which reliable data existed. Extrapolation functions were fit to viscoelastic parameters, which predicted the properties up to 1,000 Hz. Frequency trends of Zyderm were similar to those previously reported, whereas magnitudes were different. The elastic moduli logarithmically increased with frequency, whereas dynamic viscosity demonstrated shear thinning, a condition of primary importance for humans to vocalize over a broad frequency range. Previous measurements were extended from 15 Hz up to 74 Hz. Differences in magnitude between a previous study and the present study were attributed to particulate orientation during testing. Cymetra was found to have nearly identical viscoelastic properties to those of bovine collagen, both in magnitude and frequency trend, with reliable measures extending up to 81 Hz. Rheologic properties of the hyaluronic acid gel were the closest match to cadaveric vocal fold mucosa in magnitude and frequency trend. Viscoelastic properties of Cymetra and Zyderm are nearly the same and are significantly greater than those of vocal fold mucosa. HA-DTPH possesses a good viscoelastic match to vocal fold mucosa and may be useful in future lamina propria repair.

  7. Storage of Unfed and Leftover Mothers' Own Milk.

    PubMed

    Fogleman, April D; Meng, Ting; Osborne, Jason; Perrin, Maryanne T; Jones, Frances; Allen, Jonathan C

    The objective was to examine the bacteriological and immunological properties of freshly expressed, previously frozen, and leftover mothers' own milk during storage. In the first of two pilot studies, 12 mother-infant dyads participated. The milk studied included freshly expressed unfed and freshly expressed leftover milk. Milk samples were stored at 24°C, 4°C, or -20°C. In the second pilot study, 11 mother-infant dyads participated. The milk studied included milk that had been previously frozen, including previously frozen leftover milk. Milk samples were stored at 24°C and 4°C. After storage in both studies, the milk was analyzed for bacteriological and immunological properties. Bacteriological and immunological characteristics of freshly expressed unfed and freshly expressed leftover milk and previously frozen unfed and previously frozen leftover milk remained stable during storage at 4°C for at least 6 days. The quality of all groups of mothers' milk declined when stored at 24°C for longer than 3 hours. While this study provides evidence that human milk might be safe at longer storage times, storage guidelines should not be revised until more research is performed. This study serves as a call to action for more research on the topic of human milk storage, specifically leftover human milk. The study provides information to inform future study designs on the topic of unpasteurized human milk storage. More research is needed regarding leftover human milk storage with a greater number of participants, determination of the quality of human milk, and the storage of human milk in a real-life setting.

  8. Sample classification for improved performance of PLS models applied to the quality control of deep-frying oils of different botanic origins analyzed using ATR-FTIR spectroscopy.

    PubMed

    Kuligowski, Julia; Carrión, David; Quintás, Guillermo; Garrigues, Salvador; de la Guardia, Miguel

    2011-01-01

    The selection of an appropriate calibration set is a critical step in multivariate method development. In this work, the effect of using different calibration sets, based on a previous classification of unknown samples, on the partial least squares (PLS) regression model performance has been discussed. As an example, attenuated total reflection (ATR) mid-infrared spectra of deep-fried vegetable oil samples from three botanical origins (olive, sunflower, and corn oil), with increasing polymerized triacylglyceride (PTG) content induced by a deep-frying process were employed. The use of a one-class-classifier partial least squares-discriminant analysis (PLS-DA) and a rooted binary directed acyclic graph tree provided accurate oil classification. Oil samples fried without foodstuff could be classified correctly, independent of their PTG content. However, class separation of oil samples fried with foodstuff, was less evident. The combined use of double-cross model validation with permutation testing was used to validate the obtained PLS-DA classification models, confirming the results. To discuss the usefulness of the selection of an appropriate PLS calibration set, the PTG content was determined by calculating a PLS model based on the previously selected classes. In comparison to a PLS model calculated using a pooled calibration set containing samples from all classes, the root mean square error of prediction could be improved significantly using PLS models based on the selected calibration sets using PLS-DA, ranging between 1.06 and 2.91% (w/w).

  9. A test method for determining adhesion forces and Hamaker constants of cementitious materials using atomic force microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lomboy, Gilson; Sundararajan, Sriram, E-mail: srirams@iastate.edu; Wang Kejin

    2011-11-15

    A method for determining Hamaker constant of cementitious materials is presented. The method involved sample preparation, measurement of adhesion force between the tested material and a silicon nitride probe using atomic force microscopy in dry air and in water, and calculating the Hamaker constant using appropriate contact mechanics models. The work of adhesion and Hamaker constant were computed from the pull-off forces using the Johnson-Kendall-Roberts and Derjagin-Muller-Toropov models. Reference materials with known Hamaker constants (mica, silica, calcite) and commercially available cementitious materials (Portland cement (PC), ground granulated blast furnace slag (GGBFS)) were studied. The Hamaker constants of the reference materialsmore » obtained are consistent with those published by previous researchers. The results indicate that PC has a higher Hamaker constant than GGBFS. The Hamaker constant of PC in water is close to the previously predicted value C{sub 3}S, which is attributed to short hydration time ({<=} 45 min) used in this study.« less

  10. Adolescents' physical activity is associated with previous and current physical activity practice by their parents.

    PubMed

    Christofaro, Diego Giulliano Destro; Andersen, Lars Bo; Andrade, Selma Maffei de; Barros, Mauro Virgílio Gomes de; Saraiva, Bruna Thamyres Ciccotti; Fernandes, Rômulo Araújo; Ritti-Dias, Raphael Mendes

    The purpose of this study was to determine whether parents' current and previous physical activity practice is associated with adolescents' physical activity. The sample was composed of 1231 adolescents (14-17 years), and 1202 mothers and 871 fathers were interviewed. Weight and height of the adolescents were measured. Self-reported parents' weight and height were obtained. The current and previous physical activity levels (Baecke's questionnaire) of parents (during childhood and adolescence) and adolescents' physical activity levels were obtained using a questionnaire. The magnitude of the associations between parent and adolescent physical activity levels was determined by binary logistic regression (adjusted by sex, age, and socioeconomic level of adolescents and education level of parents). The current physical activity practice by parents was associated with adolescents' physical activity (p<0.001). The physical activities reported by parents in their childhood and adolescence were also associated with higher physical activity levels among adolescents. Adolescents whose parents were both physically active in the past and present were six times (OR=6.67 [CI=1.94-22.79]) more likely to be physically active compared to adolescents with no parents who were physically active in the past. The current and previous physical activities of parents were associated with higher levels of physical activity in adolescents, even after controlling for confounding factors. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  11. A thermal emission spectral library of rock-forming minerals

    NASA Astrophysics Data System (ADS)

    Christensen, Philip R.; Bandfield, Joshua L.; Hamilton, Victoria E.; Howard, Douglas A.; Lane, Melissa D.; Piatek, Jennifer L.; Ruff, Steven W.; Stefanov, William L.

    2000-04-01

    A library of thermal infrared spectra of silicate, carbonate, sulfate, phosphate, halide, and oxide minerals has been prepared for comparison to spectra obtained from planetary and Earth-orbiting spacecraft, airborne instruments, and laboratory measurements. The emphasis in developing this library has been to obtain pure samples of specific minerals. All samples were hand processed and analyzed for composition and purity. The majority are 710-1000 μm particle size fractions, chosen to minimize particle size effects. Spectral acquisition follows a method described previously, and emissivity is determined to within 2% in most cases. Each mineral spectrum is accompanied by descriptive information in database form including compositional information, sample quality, and a comments field to describe special circumstances and unique conditions. More than 150 samples were selected to include the common rock-forming minerals with an emphasis on igneous and sedimentary minerals. This library is available in digital form and will be expanded as new, well-characterized samples are acquired.

  12. The relationship between 63days of 24-h urinary free cortisol and hair cortisol levels in 10 healthy individuals.

    PubMed

    van Ockenburg, S L; Schenk, H M; van der Veen, A; van Rossum, E F C; Kema, I P; Rosmalen, J G M

    2016-11-01

    Interest in measuring cortisol in scalp hair is increasing because of its assumed ability to provide a historical timeline of previous systemic levels of cortisol. Yet, it remains uncertain how well hair cortisol represents the total systemic secretion of cortisol over time. Ten healthy individuals collected 24-h urine samples for 63 consecutive days and provided a hair sample at the end of the study period. 24-h urinary creatinine levels in every urine sample were determined to assess completeness of the samples. Cortisol levels in 24-h urine samples and in hair were measured with liquid chromatography tandem mass spectrometry. The correlations between urinary cortisol and hair cortisol were calculated using Kendall's tau. We found a nonsignificant moderate correlation between average urinary cortisol secretion and average hair cortisol concentration r т =0.422, p=0.089. Hair cortisol concentration correlates low to moderately with 24-h urinary cortisol concentration over a period of 63days. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Ranked set sampling: cost and optimal set size.

    PubMed

    Nahhas, Ramzi W; Wolfe, Douglas A; Chen, Haiying

    2002-12-01

    McIntyre (1952, Australian Journal of Agricultural Research 3, 385-390) introduced ranked set sampling (RSS) as a method for improving estimation of a population mean in settings where sampling and ranking of units from the population are inexpensive when compared with actual measurement of the units. Two of the major factors in the usefulness of RSS are the set size and the relative costs of the various operations of sampling, ranking, and measurement. In this article, we consider ranking error models and cost models that enable us to assess the effect of different cost structures on the optimal set size for RSS. For reasonable cost structures, we find that the optimal RSS set sizes are generally larger than had been anticipated previously. These results will provide a useful tool for determining whether RSS is likely to lead to an improvement over simple random sampling in a given setting and, if so, what RSS set size is best to use in this case.

  14. LATERAL HEAT FLOW INFRARED THERMOGRAPHY FOR THICKNESS INDEPENDENT DETERMINATION OF THERMAL DIFFUSIVITY IN CFRP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tralshawala, Nilesh; Howard, Don; Knight, Bryon

    2008-02-28

    In conventional infrared thermography, determination of thermal diffusivity requires thickness information. Recently GE has been experimenting with the use of lateral heat flow to determine thermal diffusivity without thickness information. This work builds on previous work at NASA Langley and Wayne State University but we incorporate thermal time of flight (tof) analysis rather than curve fitting to obtain quantitative information. We have developed appropriate theoretical models and a tof based data analysis framework to experimentally determine all components of thermal diffusivity from the time-temperature measurements. Initial validation was carried out using finite difference simulations. Experimental validation was done using anisotropicmore » carbon fiber reinforced polymer (CFRP) composites. We found that in the CFRP samples used, the in-plane component of diffusivity is about eight times larger than the through-thickness component.« less

  15. Barb geometry of asymmetrical feathers reveals a transitional morphology in the evolution of avian flight

    PubMed Central

    Feo, Teresa J.; Field, Daniel J.; Prum, Richard O.

    2015-01-01

    The geometry of feather barbs (barb length and barb angle) determines feather vane asymmetry and vane rigidity, which are both critical to a feather's aerodynamic performance. Here, we describe the relationship between barb geometry and aerodynamic function across the evolutionary history of asymmetrical flight feathers, from Mesozoic taxa outside of modern avian diversity (Microraptor, Archaeopteryx, Sapeornis, Confuciusornis and the enantiornithine Eopengornis) to an extensive sample of modern birds. Contrary to previous assumptions, we find that barb angle is not related to vane-width asymmetry; instead barb angle varies with vane function, whereas barb length variation determines vane asymmetry. We demonstrate that barb geometry significantly differs among functionally distinct portions of flight feather vanes, and that cutting-edge leading vanes occupy a distinct region of morphospace characterized by small barb angles. This cutting-edge vane morphology is ubiquitous across a phylogenetically and functionally diverse sample of modern birds and Mesozoic stem birds, revealing a fundamental aerodynamic adaptation that has persisted from the Late Jurassic. However, in Mesozoic taxa stemward of Ornithurae and Enantiornithes, trailing vane barb geometry is distinctly different from that of modern birds. In both modern birds and enantiornithines, trailing vanes have larger barb angles than in comparatively stemward taxa like Archaeopteryx, which exhibit small trailing vane barb angles. This discovery reveals a previously unrecognized evolutionary transition in flight feather morphology, which has important implications for the flight capacity of early feathered theropods such as Archaeopteryx and Microraptor. Our findings suggest that the fully modern avian flight feather, and possibly a modern capacity for powered flight, evolved crownward of Confuciusornis, long after the origin of asymmetrical flight feathers, and much later than previously recognized. PMID:25673687

  16. The relationship between lower extremity alignment and Medial Tibial Stress Syndrome among non-professional athletes

    PubMed Central

    Raissi, Golam Reza D; Cherati, Afsaneh D Safar; Mansoori, Kourosh D; Razi, Mohammad D

    2009-01-01

    Objective To determine the relationship between lower extremity alignment and MTSS amongst non-professional athletes Design In a prospective Study, sixty six subjects were evaluated. Bilateral navicular drop test, Q angle, Achilles angle, tibial angle, intermalleolar and intercondylar distance were measured. In addition, runner's height, body mass, history of previous running injury, running experience was recorded. Runners were followed for 17 weeks to determine occurrence of MTSS. Results The overall injury rate for MTSS was 19.7%. The MTSS injury rate in girls (22%) was not significantly different from the rate in boys (14.3%). Most MTSS injuries were induced after 60 hours of exercise, which did not differ between boys and girls. There was a significant difference in right and left navicular drop (ND) in athletes with MTSS. MTSS had no significant correlation with other variables including Quadriceps, Tibia and Achilles angles, intercondylar and intermaleolar lengths and lower extremity lengths. Limitation All measurements performed in this study were uniplanar and static. The small sample size deemed our main limitation. The accurate assessment of participants with previous history of anterior leg pain for MTSS was another limitation. Conclusion Although a significant relationship between navicular drop and MTSS was found in this study; there was not any significant relationship between lower extremity alignment and MTSS in our sample study. PMID:19519909

  17. Investigating a continuous shear strain function for depth-dependent properties of native and tissue engineering cartilage using pixel-size data.

    PubMed

    Motavalli, Mostafa; Whitney, G Adam; Dennis, James E; Mansour, Joseph M

    2013-12-01

    A previously developed novel imaging technique for determining the depth dependent properties of cartilage in simple shear is implemented. Shear displacement is determined from images of deformed lines photobleached on a sample, and shear strain is obtained from the derivative of the displacement. We investigated the feasibility of an alternative systematic approach to numerical differentiation for computing the shear strain that is based on fitting a continuous function to the shear displacement. Three models for a continuous shear displacement function are evaluated: polynomials, cubic splines, and non-parametric locally weighted scatter plot curves. Four independent approaches are then applied to identify the best-fit model and the accuracy of the first derivative. One approach is based on the Akaiki Information Criteria, and the Bayesian Information Criteria. The second is based on a method developed to smooth and differentiate digitized data from human motion. The third method is based on photobleaching a predefined circular area with a specific radius. Finally, we integrate the shear strain and compare it with the total shear deflection of the sample measured experimentally. Results show that 6th and 7th order polynomials are the best models for the shear displacement and its first derivative. In addition, failure of tissue-engineered cartilage, consistent with previous results, demonstrates the qualitative value of this imaging approach. © 2013 Elsevier Ltd. All rights reserved.

  18. Plan for Subdividing Genesis Mission Diamond-on-Silicon 60000 Solar Wind Collector

    NASA Technical Reports Server (NTRS)

    Burkett, Patti J.; Allton, J. A.; Clemett, S. J.; Gonzales, C. P.; Lauer, H. V., Jr.; Nakamura-Messenger, K.; Rodriquez, M. C.; See, T. H.; Sutter, B.

    2013-01-01

    NASA's Genesis solar wind sample return mission experienced an off nominal landing resulting in broken, albeit useful collectors. Sample 60000 from the collector is comprised of diamond-like-carbon film on a float zone (FZ) silicon wafer substrate Diamond-on-Silicon (DOS), and is highly prized for its higher concentration of solar wind (SW) atoms. A team of scientist at the Johnson Space Center was charged with determining the best, nondestructive and noncontaminating method to subdivide the specimen that would result in a 1 sq. cm subsample for allocation and analysis. Previous work included imaging of the SW side of 60000, identifying the crystallographic orientation of adjacent fragments, and devising an initial cutting plan.

  19. Mars Sample Return Using Commercial Capabilities: Propulsive Entry, Descent and Landing

    NASA Technical Reports Server (NTRS)

    Lemke, Lawrence G.; Gonzales, Andrew A.; Huynh, Loc C.

    2014-01-01

    Mars Sample Return (MSR) is the highest priority science mission for the next decade as recommended by the recent Decadal Survey of Planetary Science. The objective of the study was to determine whether emerging commercial capabilities can be integrated into to such a mission. The premise of the study is that commercial capabilities can be more efficient than previously described systems, and by using fewer systems and fewer or less extensive launches, overall mission cost can be reduced. This presentation describes an EDL technique using planned upgrades to the Dragon capsule to perform a Supersonic Retropulsion Entry - Red Dragon concept. Landed Payload capability meets mission requirements for a MSR Architecture that reduces complexity.

  20. Double-flow focused liquid injector for efficient serial femtosecond crystallography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oberthuer, Dominik; Knoška, Juraj; Wiedorn, Max O.

    Serial femtosecond crystallography requires reliable and efficient delivery of fresh crystals across the beam of an X-ray free-electron laser over the course of an experiment. We introduce a double-flow focusing nozzle to meet this challenge, with significantly reduced sample consumption, while improving jet stability over previous generations of nozzles. We demonstrate its use to determine the first room-temperature structure of RNA polymerase II at high resolution, revealing new structural details. Furthermore, the double flow-focusing nozzles were successfully tested with three other protein samples and the first room temperature structure of an extradiol ring-cleaving dioxygenase was solved by utilizing the improvedmore » operation and characteristics of these devices.« less

  1. Double-flow focused liquid injector for efficient serial femtosecond crystallography

    PubMed Central

    Oberthuer, Dominik; Knoška, Juraj; Wiedorn, Max O.; Beyerlein, Kenneth R.; Bushnell, David A.; Kovaleva, Elena G.; Heymann, Michael; Gumprecht, Lars; Kirian, Richard A.; Barty, Anton; Mariani, Valerio; Tolstikova, Aleksandra; Adriano, Luigi; Awel, Salah; Barthelmess, Miriam; Dörner, Katerina; Xavier, P. Lourdu; Yefanov, Oleksandr; James, Daniel R.; Nelson, Garrett; Wang, Dingjie; Calvey, George; Chen, Yujie; Schmidt, Andrea; Szczepek, Michael; Frielingsdorf, Stefan; Lenz, Oliver; Snell, Edward; Robinson, Philip J.; Šarler, Božidar; Belšak, Grega; Maček, Marjan; Wilde, Fabian; Aquila, Andrew; Boutet, Sébastien; Liang, Mengning; Hunter, Mark S.; Scheerer, Patrick; Lipscomb, John D.; Weierstall, Uwe; Kornberg, Roger D.; Spence, John C. H.; Pollack, Lois; Chapman, Henry N.; Bajt, Saša

    2017-01-01

    Serial femtosecond crystallography requires reliable and efficient delivery of fresh crystals across the beam of an X-ray free-electron laser over the course of an experiment. We introduce a double-flow focusing nozzle to meet this challenge, with significantly reduced sample consumption, while improving jet stability over previous generations of nozzles. We demonstrate its use to determine the first room-temperature structure of RNA polymerase II at high resolution, revealing new structural details. Moreover, the double flow-focusing nozzles were successfully tested with three other protein samples and the first room temperature structure of an extradiol ring-cleaving dioxygenase was solved by utilizing the improved operation and characteristics of these devices. PMID:28300169

  2. Double-flow focused liquid injector for efficient serial femtosecond crystallography

    DOE PAGES

    Oberthuer, Dominik; Knoška, Juraj; Wiedorn, Max O.; ...

    2017-03-16

    Serial femtosecond crystallography requires reliable and efficient delivery of fresh crystals across the beam of an X-ray free-electron laser over the course of an experiment. We introduce a double-flow focusing nozzle to meet this challenge, with significantly reduced sample consumption, while improving jet stability over previous generations of nozzles. We demonstrate its use to determine the first room-temperature structure of RNA polymerase II at high resolution, revealing new structural details. Furthermore, the double flow-focusing nozzles were successfully tested with three other protein samples and the first room temperature structure of an extradiol ring-cleaving dioxygenase was solved by utilizing the improvedmore » operation and characteristics of these devices.« less

  3. Micro-crystallography comes of age.

    PubMed

    Smith, Janet L; Fischetti, Robert F; Yamamoto, Masaki

    2012-10-01

    The latest revolution in macromolecular crystallography was incited by the development of dedicated, user friendly, micro-crystallography beam lines. Brilliant X-ray beams of diameter 20 μm or less, now available at most synchrotron sources, enable structure determination from samples that previously were inaccessible. Relative to traditional crystallography, crystals with one or more small dimensions have diffraction patterns with vastly improved signal-to-noise when recorded with an appropriately matched beam size. Structures can be solved from isolated, well diffracting regions within inhomogeneous samples. This review summarizes the technological requirements and approaches to producing micro-beams and how they continue to change the practice of crystallography. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Iron variation within a granitic pluton as determined by near-infrared reflectance

    NASA Technical Reports Server (NTRS)

    Baird, A. K.

    1984-01-01

    One-hundred fifty-one previously chemically analyzed samples of tonalite from the Lakeview Mountains pluton, southern California batholith, were analyzed for their iron content using near-infrared spectrophotometry. Compared to the earlier analyses of the same sample set by X-ray fluorescence spectrography, the infrared data have higher analytical variance but clearly define patterns of compositional zonation in the pluton which are closely similar to those patterns obtained from X-ray data; petrogenetic interpretations for the pluton would be the same from either data set. Infrared spectral data can be obtained directly in the field with relatively simple instruments and field measurements can be made to average local heterogeneities that often mask significant plutonic variations.

  5. Infrared reflectance spectra of Na2S with contaminant Na2CO3 - Effects of adsorbed H2O and CO2 and relation to studies of Io

    NASA Technical Reports Server (NTRS)

    Nash, Douglas B.

    1988-01-01

    A previously reported laboratory determination of the IR spectrum of Na2S is presently noted to have been incorrectly interpreted, due to the inadvertent contamination of the sample with Na2CO3. New Na2S spectra are presented, and the Na2CO3 spectrum is examined in order to demonstrate that this phase is the primary sample contaminant. Na2S is a candidate surface component on the Jupiter satellite, Io, in view of its apparent high IR brightness and spectral neutrality in the 1-5 micron range.

  6. First full-length genome sequence of the polerovirus luffa aphid-borne yellows virus (LABYV) reveals the presence of at least two consensus sequences in an isolate from Thailand.

    PubMed

    Knierim, Dennis; Maiss, Edgar; Kenyon, Lawrence; Winter, Stephan; Menzel, Wulf

    2015-10-01

    Luffa aphid-borne yellows virus (LABYV) was proposed as the name for a previously undescribed polerovirus based on partial genome sequences obtained from samples of cucurbit plants collected in Thailand between 2008 and 2013. In this study, we determined the first full-length genome sequence of LABYV. Based on phylogenetic analysis and genome properties, it is clear that this virus represents a distinct species in the genus Polerovirus. Analysis of sequences from sample TH24, which was collected in 2010 from a luffa plant in Thailand, reveals the presence of two different full-length genome consensus sequences.

  7. Attributing selected costs to intimate partner violence in a sample of women who have left abusive partners: a social determinants of health approach.

    PubMed

    Varcoe, Colleen; Hankivsky, Olena; Ford-Gilboe, Marilyn; Wuest, Judith; Wilk, Piotr; Hammerton, Joanne; Campbell, Jacquelyn

    2011-01-01

    Selected costs associated with intimate partner violence were estimated for a community sample of 309 Canadian women who left abusive male partners on average 20 months previously. Total annual estimated costs of selected public- and private-sector expenditures attributable to violence were $13,162.39 per woman. This translates to a national annual cost of $6.9 billion for women aged 19–65 who have left abusive partners; $3.1 billion for those experiencing violence within the past three years. Results indicate that costs continue long after leaving, and call for recognition in policy that leaving does not coincide with ending violence.

  8. Use of stable carbon isotope ratios to determine the source of cypermethrin in so-called natural plant extract formulations used for organic farming.

    PubMed

    Kawashima, Hiroto; Kariya, Takuro

    2017-03-01

    Some natural plant extract formulations (NPEFs, also referred to as essential oils) used in organic farming have been shown to contain synthetic pesticides. We obtained samples of four NPEFs (Muso, Hekiro, Kensogen-Ten, and Nurse Green) that were contaminated with the synthetic pyrethroid cypermethrin, and we used gas chromatography coupled with combustion, cryofocusing, and isotope ratio mass spectrometry to determine the stable carbon isotope ratios (δ 13 C) for the cypermethrin in the four NPEF samples, as well as in ten cypermethrin reagents and two commercial pesticide formulations (Agrothrin emulsion and Agrothrin water-dispersible powder). Our goal was to identify the source of the cypermethrin in the NPEFs. Cryofocusing markedly sharpened the cypermethrin peak and thus improved the accuracy and precision of the determined δ 13 C values. The δ 13 C values (± SD) of the 16 cypermethrin samples ranged from -28.3 ± 0.2 to -24.5 ± 0.2 ‰. Surprisingly, the four NPEFs showed similar δ 13 C values (-26.8 to -27.3 ‰), suggesting that the cypermethrin in all the samples came from the same source (either the same chemical reaction or the same primary material). This possibility was supported by previously published results. In addition, the δ 13 C values of the two commercial pesticides were similar to the values for the NPEFs, suggesting that the commercial pesticides had been diluted and sold as NPEFs.

  9. Multiactinide Analysis with Accelerator Mass Spectrometry for Ultratrace Determination in Small Samples: Application to an in Situ Radionuclide Tracer Test within the Colloid Formation and Migration Experiment at the Grimsel Test Site (Switzerland).

    PubMed

    Quinto, Francesca; Blechschmidt, Ingo; Garcia Perez, Carmen; Geckeis, Horst; Geyer, Frank; Golser, Robin; Huber, Florian; Lagos, Markus; Lanyon, Bill; Plaschke, Markus; Steier, Peter; Schäfer, Thorsten

    2017-07-05

    The multiactinide analysis with accelerator mass spectrometry (AMS) was applied to samples collected from the run 13-05 of the Colloid Formation and Migration (CFM) experiment at the Grimsel Test Site (GTS). In this in situ radionuclide tracer test, the environmental behavior of 233 U, 237 Np, 242 Pu, and 243 Am was investigated in a water conductive shear zone under conditions relevant for a nuclear waste repository in crystalline rock. The concentration of the actinides in the GTS groundwater was determined with AMS over 6 orders of magnitude from ∼15 pg/g down to ∼25 ag/g. Levels above 10 fg/g were investigated with both sector field inductively coupled plasma mass spectrometry (SF-ICPMS) and AMS. Agreement within a relative uncertainty of 50% was found for 237 Np, 242 Pu, and 243 Am concentrations determined with the two analytical methods. With the extreme sensitivity of AMS, the long-term release and retention of the actinides was investigated over 8 months in the tailing of the breakthrough curve of run 13-05 as well as in samples collected up to 22 months after. Furthermore, the evidence of masses 241 and 244 u in the CFM samples most probably representing 241 Am and 244 Pu employed in a previous tracer test demonstrated the analytical capability of AMS for in situ studies lasting more than a decade.

  10. Financial management skills are associated with food insecurity in a sample of households with children in the United States.

    PubMed

    Gundersen, Craig G; Garasky, Steven B

    2012-10-01

    Food insecurity is one of the leading public health challenges facing children in the United States today. Reducing food insecurity and its attendant consequences requires an understanding of the determinants of food insecurity. Although previous work has greatly advanced our understanding of these determinants, the role of one of the oft-speculated important determinants of food insecurity, household financial management skills, has not been considered. To address this research lacuna, we use a recently conducted survey, the Survey of Household Finances and Childhood Obesity, that has information on specific financial management practices, impressions of financial management skills, and households' food insecurity. The sample included 904 households with children. Within this sample, 19.3% were food insecure and, for our central financial management skill variable, the mean value was 3.55 on a 5-point scale. Probit regression models estimated the probability of a household being food insecure as conditional on financial management skills and other covariates. We found a large and significant inverse relationship between a respondent's use of specific financial management practices and food insecurity and between a respondent's confidence in his or her financial management skills and food insecurity. That is, households with greater financial management abilities are less likely to be food insecure. This finding also holds when the sample is restricted to households with incomes <200% of the poverty line. These results suggest that improving households' financial management skills has the potential to reduce food insecurity in the United States.

  11. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    PubMed

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  12. Profiling quinones in ambient air samples collected from the Athabasca region (Canada).

    PubMed

    Wnorowski, Andrzej; Charland, Jean-Pierre

    2017-12-01

    This paper presents new findings on polycyclic aromatic hydrocarbon oxidation products-quinones that were collected in ambient air samples in the proximity of oil sands exploration. Quinones were characterized for their diurnal concentration variability, phase partitioning, and molecular size distribution. Gas-phase (GP) and particle-phase (PM) ambient air samples were collected separately in the summer; a lower quinone content was observed in the PM samples from continuous 24-h sampling than from combined 12-h sampling (day and night). The daytime/nocturnal samples demonstrated that nighttime conditions led to lower concentrations and some quinones not being detected. The highest quinone levels were associated with wind directions originating from oil sands exploration sites. The statistical correlation with primary pollutants directly emitted from oil sands industrial activities indicated that the bulk of the detected quinones did not originate directly from primary emission sources and that quinone formation paralleled a reduction in primary source NO x levels. This suggests a secondary chemical transformation of primary pollutants as the origin of the determined quinones. Measurements of 19 quinones included five that have not previously been reported in ambient air or in Standard Reference Material 1649a/1649b and seven that have not been previously measured in ambient air in the underivatized form. This is the first paper to report on quinone characterization in secondary organic aerosols originating from oil sands activities, to distinguish chrysenequinone and anthraquinone positional isomers in ambient air, and to report the requirement of daylight conditions for benzo[a]pyrenequinone and naphthacenequinone to be present in ambient air. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  13. Induction of Macrophage Chemotaxis by Aortic Extracts from Patients with Marfan Syndrome Is Related to Elastin Binding Protein

    PubMed Central

    Guo, Gao; Gehle, Petra; Doelken, Sandra; Martin-Ventura, José Luis; von Kodolitsch, Yskert; Hetzer, Roland; Robinson, Peter N.

    2011-01-01

    Marfan syndrome is an autosomal dominantly inherited disorder of connective tissue with prominent skeletal, ocular, and cardiovascular manifestations. Aortic aneurysm and dissection are the major determinants of premature death in untreated patients. In previous work, we showed that extracts of aortic tissues from the mgR mouse model of Marfan syndrome showed increased chemotactic stimulatory activity related to the elastin-binding protein. Aortic samples were collected from 6 patients with Marfan syndrome and 8 with isolated aneurysms of the ascending aorta. Control samples were obtained from 11 organ donors without known vascular or connective tissue diseases. Soluble proteins extracted from the aortic samples of the two patient groups were compared against buffer controls and against the aortic samples from controls with respect to the ability to induce macrophage chemotaxis as measured using a modified Boyden chamber, as well as the reactivity to a monoclonal antibody BA4 against bioactive elastin peptides using ELISA. Samples from Marfan patients displayed a statistically significant increase in chemotactic inductive activity compared to control samples. Additionally, reactivity to BA4 was significantly increased. Similar statistically significant increases were identified for the samples from patients with idiopathic thoracic aortic aneurysm. There was a significant correlation between the chemotactic index and BA4 reactivity, and the increases in chemotactic activity of extracts from Marfan patients could be inhibited by pretreatment with lactose, VGVAPG peptides, or BA4, which indicates the involvement of EBP in mediating the effects. Our results demonstrate that aortic extracts of patients with Marfan syndrome can elicit macrophage chemotaxis, similar to our previous study on aortic extracts of the mgR mouse model of Marfan syndrome (Guo et al., Circulation 2006; 114:1855-62). PMID:21647416

  14. Clustering on very small scales from a large sample of confirmed quasar pairs: does quasar clustering track from Mpc to kpc scales?

    NASA Astrophysics Data System (ADS)

    Eftekharzadeh, S.; Myers, A. D.; Hennawi, J. F.; Djorgovski, S. G.; Richards, G. T.; Mahabal, A. A.; Graham, M. J.

    2017-06-01

    We present the most precise estimate to date of the clustering of quasars on very small scales, based on a sample of 47 binary quasars with magnitudes of g < 20.85 and proper transverse separations of ˜25 h-1 kpc. Our sample of binary quasars, which is about six times larger than any previous spectroscopically confirmed sample on these scales, is targeted using a kernel density estimation (KDE) technique applied to Sloan Digital Sky Survey (SDSS) imaging over most of the SDSS area. Our sample is 'complete' in that all of the KDE target pairs with 17.0 ≲ R ≲ 36.2 h-1 kpc in our area of interest have been spectroscopically confirmed from a combination of previous surveys and our own long-slit observational campaign. We catalogue 230 candidate quasar pairs with angular separations of <8 arcsec, from which our binary quasars were identified. We determine the projected correlation function of quasars (\\bar{W}_p) in four bins of proper transverse scale over the range 17.0 ≲ R ≲ 36.2 h-1 kpc. The implied small-scale quasar clustering amplitude from the projected correlation function, integrated across our entire redshift range, is A = 24.1 ± 3.6 at ˜26.6 h-1 kpc. Our sample is the first spectroscopically confirmed sample of quasar pairs that is sufficiently large to study how quasar clustering evolves with redshift at ˜25 h-1 kpc. We find that empirical descriptions of how quasar clustering evolves with redshift at ˜25 h-1 Mpc also adequately describe the evolution of quasar clustering at ˜25 h-1 kpc.

  15. Multicommuted flow injection method for fast photometric determination of phenolic compounds in commercial virgin olive oil samples.

    PubMed

    Lara-Ortega, Felipe J; Sainz-Gonzalo, Francisco J; Gilbert-López, Bienvenida; García-Reyes, Juan F; Molina-Díaz, Antonio

    2016-01-15

    A multicommuted flow injection method has been developed for the determination of phenolic species in virgin olive oil samples. The method is based on the inhibitory effect of antioxidants on a stable and colored radical cation formation from the colorless compound N,N-dimethyl-p-phenylenediamine (DMPD(•+)) in acidic medium in the presence of Fe(III) as oxidant. The signal inhibition by phenolic species and other antioxidants is proportional to their concentration in the olive oil sample. Absorbance was recorded at 515nm by means of a modular fiber optic spectrometer. Oleuropein was used as the standard for phenols determination and 6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid (trolox) was the reference standard used for total antioxidant content calculation. Linear response was observed within the range of 250-1000mg/kg oleuropein, which was in accordance with phenolic contents observed in commercial extra virgin olive oil in the present study. Fast and low-volume liquid-liquid extraction of the samples using 60% MeOH was made previous to their insertion in the flow multicommuted system. The five three-way solenoid valves used for multicommuted liquid handling were controlled by a homemade electronic interface and Java-written software. The proposed approach was applied to different commercial extra virgin olive oil samples and the results were consistent with those obtained by the Folin Ciocalteu (FC) method. Total time for the sample preparation and the analysis required in the present approach can be drastically reduced: the throughput of the present analysis is 8 samples/h in contrast to 1sample/h of the conventional FC method. The present method is easy to implement in routine analysis and can be regarded as a feasible alternative to FC method. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Advances in 6d diffraction contrast tomography

    NASA Astrophysics Data System (ADS)

    Viganò, N.; Ludwig, W.

    2018-04-01

    The ability to measure 3D orientation fields and to determine grain boundary character plays a key role in understanding many material science processes, including: crack formation and propagation, grain coarsening, and corrosion processes. X-ray diffraction imaging techniques offer the ability to retrieve such information in a non-destructive manner. Among them, Diffraction Contrast Tomography (DCT) is a monochromatic beam, near-field technique, that uses an extended beam and offers fast mapping of 3D sample volumes. It was previously shown that the six-dimensional extension of DCT can be applied to moderately deformed samples (<= 5% total strain), made from materials that exhibit low levels of elastic deformation of the unit cell (<= 1%). In this article, we improved over the previously proposed 6D-DCT reconstruction method, through the introduction of both a more advanced forward model and reconstruction algorithm. The results obtained with the proposed improvements are compared against the reconstructions previously published in [1], using Electron Backscatter Diffraction (EBSD) measurements as a reference. The result was a noticeably higher quality reconstruction of the grain boundary positions and local orientation fields. The achieved reconstruction quality, together with the low acquisition times, render DCT a valuable tool for the stop-motion study of polycrystalline microstructures, evolving as a function of applied strain or thermal annealing treatments, for selected materials.

  17. A preliminary study on the use of (10)Be in forensic radioecology of nuclear explosion sites.

    PubMed

    Whitehead, N E; Endo, S; Tanaka, K; Takatsuji, T; Hoshi, M; Fukutani, S; Ditchburn, R G; Zondervan, A

    2008-02-01

    Cosmogenic (10)Be, known for use in dating studies, unexpectedly is also produced in nuclear explosions with an atom yield almost comparable to (e.g.) (137)Cs. There are major production routes via (13)C(n, alpha)(10)Be, from carbon dioxide in the air and the organic explosives, possibly from other bomb components and to a minor extent from the direct fission reaction. Although the detailed bomb components are speculative, carbon was certainly present in the explosives and an order of magnitude calculation is possible. The (n, alpha) cross-section was determined by irradiating graphite in a nuclear reactor, and the resulting (10)Be estimated by Accelerator Mass Spectrometry (AMS) giving a cross-section of 34.5+/-0.7mb (6-9.3MeV), within error of previous work. (10)Be should have applications in forensic radioecology. Historical environmental samples from Hiroshima, and Semipalatinsk (Kazakhstan) showed two to threefold (10)Be excesses compared with the background cosmogenic levels. A sample from Lake Chagan (a Soviet nuclear cratering experiment) contained more (10)Be than previously reported soils. (10)Be may be useful for measuring the fast neutron dose near the Hiroshima bomb hypocenter at neutron energies double those previously available.

  18. On the selection of gantry and collimator angles for isocenter localization using Winston-Lutz tests.

    PubMed

    Du, Weiliang; Johnson, Jennifer L; Jiang, Wei; Kudchadker, Rajat J

    2016-01-08

    In Winston-Lutz (WL) tests, the isocenter of a linear accelerator (linac) is determined as the intersection of radiation central axes (CAX) from multiple gantry, collimator, and couch angles. It is well known that the CAX can wobble due to mechanical imperfections of the linac. Previous studies suggested that the wobble varies with gantry and collimator angles. Therefore, the isocenter determined in the WL tests has a profound dependence on the gantry and collimator angles at which CAX are sampled. In this study, we evaluated the systematic and random errors in the iso-centers determined with different CAX sampling schemes. Digital WL tests were performed on six linacs. For each WL test, 63 CAX were sampled at nine gantry angles and seven collimator angles. Subsets of these data were used to simulate the effects of various CAX sampling schemes. An isocenter was calculated from each subset of CAX and compared against the reference isocenter, which was calculated from 48 opposing CAX. The differences between the calculated isocenters and the reference isocenters ranged from 0 to 0.8 mm. The differences diminished to less than 0.2 mm when 24 or more CAX were sampled. Isocenters determined with collimator 0° were vertically lower than those determined with collimator 90° and 270°. Isocenter localization errors in the longitudinal direction (along the axis of gantry rotation) showed a strong dependence on the collimator angle selected. The errors in all directions were significantly reduced when opposing collimator angles and opposing gantry angles were employed. The isocenter localization errors were less than 0.2 mm with the common CAX sampling scheme, which used four cardinal gantry angles and two opposing collimator angles. Reproducibility stud-ies on one linac showed that the mean and maximum variations of CAX during the WL tests were 0.053 mm and 0.30 mm, respectively. The maximal variation in the resulting isocenters was 0.068 mm if 48 CAX were used, or 0.13 mm if four CAX were used. Quantitative results from this study are useful for understanding and minimizing the isocenter uncertainty in WL tests.

  19. Egoistic, altruistic, and biospheric environmental concerns: a path analytic investigation of their determinants.

    PubMed

    Swami, Viren; Chamorro-Premuzic, Tomas; Snelgar, Rosemary; Furnham, Adrian

    2010-04-01

    Previous studies have shown that environmental concerns (ECs) can be reduced to a three-factor model - comprising altruistic, biospheric, and egoistic concerns - but there have been few studies examining individual difference predictors of ECs. In this study with 203 individuals from a British community sample, we show that biospheric concern was significantly associated with participants' age, political orientation, Machiavellianism, and the Big Five personality traits of Agreeableness, Emotional Stability, and Conscientiousness. Altruistic concern was significantly associated with sex, age, political orientation, and Machiavellianism, but not the Big Five traits, whereas egoistic concern was not significantly associated with any of these predictors except sex. These results are discussed in relation to previous work on ECs and pro-environmental behavior.

  20. Genetic polymorphisms in prehistoric Pacific islanders determined by analysis of ancient bone DNA.

    PubMed

    Hagelberg, E; Clegg, J B

    1993-05-22

    A previously characterized Asian-specific mitochondrial DNA (mtDNA) length mutation has been detected in DNA isolated from prehistoric human bones from Polynesia, including Hawaii, Chatham Islands and Society Islands. In contrast, the Asian mutation was absent in skeletal samples from the Melanesian archipelagos of New Britain and Vanuatu and in the oldest samples from Fiji, Tonga and Samoa in the central Pacific (2700-1600 years BP) although it was present in a more recent prehistoric sample from Tonga. These results, augmented by informative DNA sequence data from the hypervariable region of mtDNA, fail to support current views that the central Pacific was settled directly by voyagers from island Southeast Asia, the putative ancestors of modern Polynesians. An earlier occupation by peoples from the neighbouring Melanesian archipelagos seems more likely.

  1. K-Ca and Rb-Sr Dating of Lunar Granite 14321 Revisited

    NASA Technical Reports Server (NTRS)

    Simon, Justin I.; Shih, C.-Y.; Nyquist, L. E.

    2011-01-01

    K-Ca and Rb-Sr age determinations were made for a bulk feldspar-rich portion of an Apollo rock fragment of the pristine lunar granite clast (14321,1062), an acid-leached split of the sample, and the leachate. K-Ca and Rb-Sr data were also obtained for a whole rock sample of Apollo ferroan anorthosite (FAN, 15415). The recent detection [1] of widespread intermediate composition plagioclase indicates that the generation of a diversity of evolved lunar magmas maybe more common and therefore more important to our understanding of crust formation than previously believed. Our new data strengthen the K-Ca and Rb-Sr internal isochrons of the well-studied Apollo sample 14321 [2], which along with a renewed effort to study evolved lunar magmas will provide an improved understanding of the petrogenetic history of evolved rocks on the Moon.

  2. Acoustic levitation methods for density measurements

    NASA Technical Reports Server (NTRS)

    Trinh, E. H.; Hsu, C. J.

    1986-01-01

    The capability of ultrasonic levitators operating in air to perform density measurements has been demonstrated. The remote determination of the density of ordinary liquids as well as low density solid metals can be carried out using levitated samples with size on the order of a few millimeters and at a frequency of 20 kHz. Two basic methods may be used. The first one is derived from a previously known technique developed for acoustic levitation in liquid media, and is based on the static equilibrium position of levitated samples in the earth's gravitational field. The second approach relies on the dynamic interaction between a levitated sample and the acoustic field. The first technique appears more accurate (1 percent uncertainty), but the latter method is directly applicable to a near gravity-free environment such as that found in space.

  3. Species richness in soil bacterial communities: a proposed approach to overcome sample size bias.

    PubMed

    Youssef, Noha H; Elshahed, Mostafa S

    2008-09-01

    Estimates of species richness based on 16S rRNA gene clone libraries are increasingly utilized to gauge the level of bacterial diversity within various ecosystems. However, previous studies have indicated that regardless of the utilized approach, species richness estimates obtained are dependent on the size of the analyzed clone libraries. We here propose an approach to overcome sample size bias in species richness estimates in complex microbial communities. Parametric (Maximum likelihood-based and rarefaction curve-based) and non-parametric approaches were used to estimate species richness in a library of 13,001 near full-length 16S rRNA clones derived from soil, as well as in multiple subsets of the original library. Species richness estimates obtained increased with the increase in library size. To obtain a sample size-unbiased estimate of species richness, we calculated the theoretical clone library sizes required to encounter the estimated species richness at various clone library sizes, used curve fitting to determine the theoretical clone library size required to encounter the "true" species richness, and subsequently determined the corresponding sample size-unbiased species richness value. Using this approach, sample size-unbiased estimates of 17,230, 15,571, and 33,912 were obtained for the ML-based, rarefaction curve-based, and ACE-1 estimators, respectively, compared to bias-uncorrected values of 15,009, 11,913, and 20,909.

  4. Determination of nanomolar chromate in drinking water with solid phase extraction and a portable spectrophotometer.

    PubMed

    Ma, Jian; Yang, Bo; Byrne, Robert H

    2012-06-15

    Determination of chromate at low concentration levels in drinking water is an important analytical objective for both human health and environmental science. Here we report the use of solid phase extraction (SPE) in combination with a custom-made portable light-emitting diode (LED) spectrophotometer to achieve detection of chromate in the field at nanomolar levels. The measurement chemistry is based on a highly selective reaction between 1,5-diphenylcarbazide (DPC) and chromate under acidic conditions. The Cr-DPC complex formed in the reaction can be extracted on a commercial C18 SPE cartridge. Concentrated Cr-DPC is subsequently eluted with methanol and detected by spectrophotometry. Optimization of analytical conditions involved investigation of reagent compositions and concentrations, eluent type, flow rate (sample loading), sample volume, and stability of the SPE cartridge. Under optimized conditions, detection limits are on the order of 3 nM. Only 50 mL of sample is required for an analysis, and total analysis time is around 10 min. The targeted analytical range of 0-500 nM can be easily extended by changing the sample volume. Compared to previous SPE-based spectrophotometric methods, this analytical procedure offers the benefits of improved sensitivity, reduced sample consumption, shorter analysis time, greater operational convenience, and lower cost. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. An occupational exposure assessment of a perfluorooctanesulfonyl fluoride production site: biomonitoring.

    PubMed

    Olsen, Geary W; Logan, Perry W; Hansen, Kristen J; Simpson, Cathy A; Burris, Jean M; Burlew, Michele M; Vorarath, Phanasouk P; Venkateswarlu, Pothapragada; Schumpert, John C; Mandel, Jeffrey H

    2003-01-01

    This investigation randomly sampled a fluorochemical manufacturing employee population to determine the distribution of serum fluorochemical levels according to employees' jobs and work areas. Previous analyses of medical surveillance data have not shown significant associations between fluorochemical production employees' clinical chemistry and hematology tests and their serum PFOS and perfluorooctanoate (PFOA, C(7)F(15)COO(-)) concentrations, but may have been subject to nonparticipation bias. A random sample of the on-site film plant employee population, where fluorochemicals are not produced, determined their serum concentrations also. Of the 232 employees randomly selected for serum sampling, 186 (80%) employees participated (n=126 chemical plant; n=60 film plant). Sera samples were extracted using an ion-pairing extraction procedure and were quantitatively analyzed for seven fluorochemicals using high-pressure liquid chromatography electrospray tandem mass spectrometry methods. Geometric means (in parts per million) and 95% confidence intervals (in parentheses) of the random sample of 126 chemical plant employees were: PFOS 0.941 (0.787-1.126); PFOA 0.899 (0.722-1.120); perfluorohexanesulfonate 0.180 (0.145-0.223); N-ethyl perfluorooctanesulfonamidoacetate 0.008 (0.006-0.011); N-methyl perfluorooctanesulfonamidoacetate 0.081 (0.067-0.098); perfluorooctanesulfonamide 0.013 (0.009-0.018); and perfluorooctanesulfonamidoacetate 0.022 (0.018-0.029). These geometric means were approximately one order of magnitude higher than those observed for the film plant employees.

  6. [Iodine concentration in cooking salt consumed in Lubumbashi and the iodine status of vulnerable people: case study of pregnant women living in underprivileged areas].

    PubMed

    Banza, Bienvenue Ilunga; Lumbu, Jean Baptiste Simbi; Donnen, Philippe; Twite, Eugène Kabange; Kwete, Daniel Mikobi; Kazadi, Costa Mwadianvita; Ozoza, Jean Okolonken; Habimana, Laurence; Kalenga, Prosper Muenze Kayamba; Robert, Annie

    2016-01-01

    Consumption of low iodine salt can cause different types of disorders associated with iodine deficiency. This study aims to determine iodine content in table salt consumed in Lubumbashi and iodine status of pregnant women who are the main target of iodine deficiency. aAdescriptive cross-sectional study was devoted to an iodometric iodine analysis of 739 salt samples collected from the households and the markets of Lubumbashi in 2014. Previously, urinary iodine concentrations were determined in 225 pregnant women received for consultation from 15 March 2009 to 25 April 2011 by mineralization technique using ammonium persulphate. Our survey found that 47.5% of the cooking salt samples were adequately iodized (from 15 to 40 ppm), 36,9% of the samples had low iodine levels, 7,4% of the samples had too much iodine and 8,1% of the samples were not iodized. Iodine concentration in the analyzed cooking salt reached an overall average of 54,9%, being clearly below the WHO Standards (90%). By measuring urinary iodine concentration of pregnant women, iodine deficiency (urinary iodine <150 µg/l) was observed in 52%. The low availability of iodine from consumed salt in Lubumbashi could be responsible for a large proportion of the observed iodine deficiency in pregnant women, exposing them to the major risks for disorders associated with iodine deficiency.

  7. Relationships between processing delay and microbial load of broiler neck skin samples.

    PubMed

    Lucianez, A; Holmes, M A; Tucker, A W

    2010-01-01

    The measurable microbial load on poultry carcasses during processing is determined by a number of factors including farm or origin, processing hygiene, and external temperature. This study investigated associations between carcass microbial load and progressive delays to processing. A total of 30 carcasses were delayed immediately after defeathering and before evisceration in a commercial abattoir in groups of five, and were held at ambient temperature for 1, 2, 3, 4, 6, and 8 h. Delayed carcasses were reintroduced to the processing line, and quantitative assessment of total viable count, coliforms, Staphylococcus aureus, and Pseudomonas spp. was undertaken on neck skin flap samples collected after carcass chilling and then pooled for each group. Sampling was repeated on 5 separate days, and the data were combined. Significant increases in total viable count (P = 0.001) and coliforms (P = 0.004), but not for S. aureus or Pseudomonas loads, were observed across the 8-h period of delay. In line with previous studies, there was significant variation in microbiological data according to sampling day. In conclusion, there is a significant and measurable decline in microbiological status of uneviscerated but defeathered poultry carcasses after an 8-h delay, but the variability of sampling results, reflecting the wide range of factors that impact microbial load, means that it is not possible to determine maximum or minimum acceptable periods of processing delay based on this criterion alone.

  8. Validating a biometric authentication system: sample size requirements.

    PubMed

    Dass, Sarat C; Zhu, Yongfang; Jain, Anil K

    2006-12-01

    Authentication systems based on biometric features (e.g., fingerprint impressions, iris scans, human face images, etc.) are increasingly gaining widespread use and popularity. Often, vendors and owners of these commercial biometric systems claim impressive performance that is estimated based on some proprietary data. In such situations, there is a need to independently validate the claimed performance levels. System performance is typically evaluated by collecting biometric templates from n different subjects, and for convenience, acquiring multiple instances of the biometric for each of the n subjects. Very little work has been done in 1) constructing confidence regions based on the ROC curve for validating the claimed performance levels and 2) determining the required number of biometric samples needed to establish confidence regions of prespecified width for the ROC curve. To simplify the analysis that address these two problems, several previous studies have assumed that multiple acquisitions of the biometric entity are statistically independent. This assumption is too restrictive and is generally not valid. We have developed a validation technique based on multivariate copula models for correlated biometric acquisitions. Based on the same model, we also determine the minimum number of samples required to achieve confidence bands of desired width for the ROC curve. We illustrate the estimation of the confidence bands as well as the required number of biometric samples using a fingerprint matching system that is applied on samples collected from a small population.

  9. VALIDATION OF STANDARD ANALYTICAL PROTOCOL FOR ...

    EPA Pesticide Factsheets

    There is a growing concern with the potential for terrorist use of chemical weapons to cause civilian harm. In the event of an actual or suspected outdoor release of chemically hazardous material in a large area, the extent of contamination must be determined. This requires a system with the ability to prepare and quickly analyze a large number of contaminated samples for the traditional chemical agents, as well as numerous toxic industrial chemicals. Liquid samples (both aqueous and organic), solid samples (e.g., soil), vapor samples (e.g., air) and mixed state samples, all ranging from household items to deceased animals, may require some level of analyses. To meet this challenge, the U.S. Environmental Protection Agency (U.S. EPA) National Homeland Security Research Center, in collaboration with experts from across U.S. EPA and other Federal Agencies, initiated an effort to identify analytical methods for the chemical and biological agents that could be used to respond to a terrorist attack or a homeland security incident. U.S. EPA began development of standard analytical protocols (SAPs) for laboratory identification and measurement of target agents in case of a contamination threat. These methods will be used to help assist in the identification of existing contamination, the effectiveness of decontamination, as well as clearance for the affected population to reoccupy previously contaminated areas. One of the first SAPs developed was for the determin

  10. Characterizing 3D sensors using the 3D modulation transfer function

    NASA Astrophysics Data System (ADS)

    Kellner, Timo; Breitbarth, Andreas; Zhang, Chen; Notni, Gunther

    2018-03-01

    The fields of optical 3D measurement system applications are continuously expanding and becoming more and more diverse. To evaluate appropriate systems for various measurement tasks, comparable parameters are necessary, whereas the 3D modulation transfer function (3D-MTF) has been established as a further criterion. Its aim is the determination of the system response between the measurement of a straight, sharp-edged cube and its opposite ideal calculated one. Within the scope of this work simulations and practical investigations regarding the 3D-MTF’s influences and its main issues are specifically investigated. Therefore, different determined edge radii representing the high-frequency spectra lead to various decreasing 3D-MTF characteristics. Furthermore, rising sampling frequencies improve its maximum transfer value to a saturation point in dependence of the radius. To approve these results of previous simulations, three fringe projection scanners were selected to determine the diversity. As the best 3D-MTF characteristic, a saturated transfer value of H_3D( f_N, 3D) = 0.79 has been identified at a sufficient sampling frequency, which is reached at four times the Nyquist limit. This high 3D resolution can mainly be achieved due to an improved camera projector interaction. Additionally, too small sampling ratios lead to uncertainties in the edge function determination, while higher ratios do not show major improvements. In conclusion, the 3D-MTF algorithm has thus been practically verified and its repeatability as well as its robustness have been confirmed.

  11. Adulteration of diesel/biodiesel blends by vegetable oil as determined by Fourier transform (FT) near infrared spectrometry and FT-Raman spectroscopy.

    PubMed

    Oliveira, Flavia C C; Brandão, Christian R R; Ramalho, Hugo F; da Costa, Leonardo A F; Suarez, Paulo A Z; Rubim, Joel C

    2007-03-28

    In this work it has been shown that the routine ASTM methods (ASTM 4052, ASTM D 445, ASTM D 4737, ASTM D 93, and ASTM D 86) recommended by the ANP (the Brazilian National Agency for Petroleum, Natural Gas and Biofuels) to determine the quality of diesel/biodiesel blends are not suitable to prevent the adulteration of B2 or B5 blends with vegetable oils. Considering the previous and actual problems with fuel adulterations in Brazil, we have investigated the application of vibrational spectroscopy (Fourier transform (FT) near infrared spectrometry and FT-Raman) to identify adulterations of B2 and B5 blends with vegetable oils. Partial least square regression (PLS), principal component regression (PCR), and artificial neural network (ANN) calibration models were designed and their relative performances were evaluated by external validation using the F-test. The PCR, PLS, and ANN calibration models based on the Fourier transform (FT) near infrared spectrometry and FT-Raman spectroscopy were designed using 120 samples. Other 62 samples were used in the validation and external validation, for a total of 182 samples. The results have shown that among the designed calibration models, the ANN/FT-Raman presented the best accuracy (0.028%, w/w) for samples used in the external validation.

  12. Determination of Mercury in Aqueous and Geologic Materials by Continuous Flow-Cold Vapor-Atomic Fluorescence Spectrometry (CVAFS)

    USGS Publications Warehouse

    Hageman, Philip L.

    2007-01-01

    New methods for the determination of total mercury in geologic materials and dissolved mercury in aqueous samples have been developed that will replace the methods currently (2006) in use. The new methods eliminate the use of sodium dichromate (Na2Cr2O7 ?2H2O) as an oxidizer and preservative and significantly lower the detection limit for geologic and aqueous samples. The new methods also update instrumentation from the traditional use of cold vapor-atomic absorption spectrometry to cold vapor-atomic fluorescence spectrometry. At the same time, the new digestion procedures for geologic materials use the same size test tubes, and the same aluminum heating block and hot plate as required by the current methods. New procedures for collecting and processing of aqueous samples use the same procedures that are currently (2006) in use except that the samples are now preserved with concentrated hydrochloric acid/bromine monochloride instead of sodium dichromate/nitric acid. Both the 'old' and new methods have the same analyst productivity rates. These similarities should permit easy migration to the new methods. Analysis of geologic and aqueous reference standards using the new methods show that these procedures provide mercury recoveries that are as good as or better than the previously used methods.

  13. Odour-causing compounds in air samples: gas-liquid partition coefficients and determination using solid-phase microextraction and GC with mass spectrometric detection.

    PubMed

    Godayol, Anna; Alonso, Mònica; Sanchez, Juan M; Anticó, Enriqueta

    2013-03-01

    A quantification method based on solid-phase microextraction followed by GC coupled to MS was developed for the determination of gas-liquid partition coefficients and for the air monitoring of a group of odour-causing compounds that had previously been found in wastewater samples including dimethyl disulphide, phenol, indole, skatole, octanal, nonanal, benzothiazole and some terpenes. Using a divinylbenzene/carboxen/polydimethylsiloxane fibre, adsorption kinetics have been studied to define an extraction time that would avoid coating saturation. It was found that for an extraction time of 10 min, external calibration could be performed in the range of 0.4-100 μg/m(3), with detection limits between 0.1 and 20 μg/m(3). Inter-day precision of the developed method was evaluated (n = 5) and RSD values between 12 and 24% were obtained for all compounds. The proposed method has been applied to the analysis of air samples surrounding a wastewater treatment plant in Catalonia (Spain). In all air samples evaluated, dimethyl disulphide, limonene and phenol were detected, and the first two were the compounds that showed the highest partition coefficients. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. The fundamental stellar parameters of FGK stars in the SEEDS survey Norman, OK 73071, USA

    NASA Astrophysics Data System (ADS)

    Rich, Evan A.; Wisniewski, John P.; McElwain, Michael W.; Hashimoto, Jun; Kudo, Tomoyuki; Kusakabe, Nobuhiko; Okamoto, Yoshiko K.; Abe, Lyu; Akiyama, Eiji; Brandner, Wolfgang; Brandt, Timothy D.; Cargile, Phillip; Carson, Joseph C.; Currie, Thayne M.; Egner, Sebastian; Feldt, Markus; Fukagawa, Misato; Goto, Miwa; Grady, Carol A.; Guyon, Olivier; Hayano, Yutaka; Hayashi, Masahiko; Hayashi, Saeko S.; Hebb, Leslie; Hełminiak, Krzysztof G.; Henning, Thomas; Hodapp, Klaus W.; Ishii, Miki; Iye, Masanori; Janson, Markus; Kandori, Ryo; Knapp, Gillian R.; Kuzuhara, Masayuki; Kwon, Jungmi; Matsuo, Taro; Mayama, Satoshi; Miyama, Shoken; Momose, Munetake; Morino, Jun-Ichi; Moro-Martin, Amaya; Nakagawa, Takao; Nishimura, Tetsuo; Oh, Daehyeon; Pyo, Tae-Soo; Schlieder, Joshua; Serabyn, Eugene; Sitko, Michael L.; Suenaga, Takuya; Suto, Hiroshi; Suzuki, Ryuji; Takahashi, Yasuhiro H.; Takami, Michihiro; Takato, Naruhisa; Terada, Hiroshi; Thalmann, Christian; Tomono, Daigo; Turner, Edwin L.; Watanabe, Makoto; Yamada, Toru; Takami, Hideki; Usuda, Tomonori; Tamura, Motohide

    2017-12-01

    Large exoplanet surveys have successfully detected thousands of exoplanets to-date. Utilizing these detections and non-detections to constrain our understanding of the formation and evolution of planetary systems also requires a detailed understanding of the basic properties of their host stars. We have determined the basic stellar properties of F, K and G stars in the Strategic Exploration of Exoplanets and Disks with Subaru (SEEDS) survey from Echelle spectra taken at the Apache Point Observatory's 3.5m telescope. Using ROBOSPECT to extract line equivalent widths and Temperature Gravity microtrubulent Velocity ITerations to calculate the fundamental parameters, we have computed Teff, log(g), vt, [Fe/H], chromospheric activity and the age for our sample. Our methodology was calibrated against previously published results for a portion of our sample. The distribution of [Fe/H] in our sample is consistent with that typical of the Solar neighbourhood. Additionally, we find the ages of most of our sample are <500 Myr, but note that we cannot determine robust ages from significantly older stars via chromospheric activity age indicators. The future meta-analysis of the frequency of wide stellar and sub-stellar companions imaged via the SEEDS survey will utilize our results to constrain the occurrence of detected comoving companions with the properties of their host stars.

  15. Lithium abundance in a sample of solar-like stars

    NASA Astrophysics Data System (ADS)

    López-Valdivia, R.; Hernández-Águila, J. B.; Bertone, E.; Chávez, M.; Cruz-Saenz de Miera, F.; Amazo-Gómez, E. M.

    2015-08-01

    We report on the determination of the lithium abundance [A(Li)] of 52 solar-like stars. For 41 objects the A(Li) here presented corresponds to the first measurement. We have measured the equivalent widths of the 6708 Å lithium feature in high-resolution spectroscopic images (R ˜ 80 000), obtained at the Observatorio Astrofísico Guillermo Haro (Sonora, Mexico), as part of the first scientific observations of the revitalized Lunar and Planetary Laboratory (LPL) Echelle Spectrograph, now known as the Cananea High-resolution Spectrograph (CanHiS). Lithium abundances were derived with the Fortran code MOOG, using as fundamental input a set of atmospheric parameters recently obtained by our group. With the help of an additional small sample with previous A(Li) determinations, we demonstrate that our lithium abundances are in agreement, to within uncertainties, with other works. Two target objects stand out from the rest of the sample. The star BD+47 3218 (Teff = 6050 ± 52 K, A(Li) = 1.86 ± 0.07 dex) lies inside the so-called lithium desert in the A(Li)-Teff plane. The other object, BD+28 4515, has an A(Li) = 3.05 ± 0.07 dex, which is the highest of our sample and compatible with the expected abundances of relatively young stars.

  16. Levels of Organochlorine Pesticides and Heavy Metals in Surface Waters of Konya Closed Basin, Turkey

    PubMed Central

    Aydin, Mehmet Emin; Ozcan, Senar; Beduk, Fatma; Tor, Ali

    2013-01-01

    The concentrations of organochlorine pesticides (OCPs), including α-, β-, γ-, and δ-hexachlorocyclohexane (HCH), heptachlor, heptachlor epoxide, dieldrin, aldrin, endrin, endrin aldehyde, endrin ketone, endosulfan I, endosulfan II, endosulfan sulfate, p,p′-DDE, p,p′-DDD, p,p′-DDT, methoxychlor, chlordane I, chlordane II, and heavy metals, such as As, Cr, Cu, Fe, Mn, and Ni in surface water samples from the Konya closed basin were determined to evaluate the level of contamination. Among all HCH isomers, β-HCH is the main isomer with a concentration range of 0.015–0.065 μg/L. DDE, DDD, and DDT were almost determined in all samples, in which DDE isomer had the highest concentration ranged from not detected to 0.037 μg/L. In all studied OCPs, aldrin showed the highest concentration at 0.220 μg/L. The concentrations of heavy metals in water samples were observed with order: Mn < Cu < Ni < As < Cr < Fe. In some samples, As, Fe, and Cr concentrations exceeded the drinking water quality recommended by EU, US EPA, WHO, and Turkish Regulation, while Cu, Ni, and Mn concentrations are below the guideline values. The levels of both OCPs and heavy metals were also compared with other previously published data. PMID:23533363

  17. Mercury concentrations in eggshells of the Southern Ground-Hornbill (Bucorvus leadbeateri) and Wattled Crane (Bugeranus carunculatus) in South Africa.

    PubMed

    Daso, Adegbenro P; Okonkwo, Jonathan O; Jansen, Raymond; Brandao, José D D O; Kotzé, Antoinette

    2015-04-01

    In this study, wild hatched eggshells were collected from the nests of threatened Wattled Crane and South Ground-Hornbill in an attempt to determine their total Hg concentrations. A total of fourteen eggshell samples from both bird species were collected from different study areas in the Mpumlanga and KwaZulu-Natal Provinces of South Africa. The eggshells were acid digested under reflux and their total Hg concentrations were determined using cold-vapour atomic absorption spectrophotometry (CV-AAS). The observed total Hg levels for the South Ground-Hornbill samples ranged from 1.31 to 8.88 µg g(-1) dry weight (dw), except for one outlier which had an elevated 75.0 µg g(-1) dw. The levels obtained for the Wattled Crane samples were relatively high and these ranged from 14.84 to 36.37 µg g(-1) dw. Generally, all the measured total Hg concentrations for the Wattled Crane samples exceeded the estimated total Hg levels derived for eggshell which were known to cause adverse reproductive effects in avian species from previous studies. Based on these findings, it is, therefore, possible that the exposure of these birds to elevated Hg may have contributed to their present population decline. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Bioavailability of an extemporaneous suspension of propafenone made from tablets.

    PubMed

    Olguín, Hugo Juárez; Pérez, Carmen Flores; Pérez, Janett Flores; Mendiola, Blanca Ramírez; Portugal, Miriam Carrasco; Chávez, Jesús Bobadilla

    2006-07-01

    Propafenone is an effective antiarrhythmic agent used in children, while in Mexico no specific formulation for children is available, which causes errors in adequate dosage. The aim of this study was to determine the bioavailability of a suspension prepared extemporaneously using commercial tablets of propafenone. The bioavailability was determined in two groups of rabbits (n = 8): the first group received a single intravenous dose of 2 mg/kg of propafenone; the second was orally administered an extemporaneous suspension of propafenone prepared from commercial tablets. Blood samples were drawn at several times during the next 24 h and analysed by HPLC to determine drug levels. The extemporaneous suspension was tested previously with satisfactory results regarding physicochemical and microbiologic stability. The area under the curve (AUC) for the i.v. route was 5600.6 ng/ml.h and for oral administration the AUC was 3327.6 ng/ml.h. The bioavailability was calculated at 59.41%. These results are consistent with previous reports for solid dosage forms. The propafenone suspension prepared extemporaneously using commercial tablets is bioavailable using an animal model; nevertheless, it is necessary to carry out human studies either in volunteers or in patients to confirm these results.

  19. Electrothermal atomisation atomic absorption conditions and matrix modifications for determining antimony, arsenic, bismuth, cadmium, gallium, gold, indium, lead, molybdenum, palladium, platinum, selenium, silver, tellurium, thallium and tin following back-extraction of organic aminohalide extracts

    USGS Publications Warehouse

    Clark, J.R.

    1986-01-01

    A multi-element organic-extraction and back-extraction procedure, that had been developed previously to eliminate matrix interferences in the determination of a large number of trace elements in complex materials such as geological samples, produced organic and aqueous solutions that were complex. Electrothermal atomisation atomic absorption conditions and matrix modifications have been developed for 13 of the extracted elements (Ag, As, Au, Bi, Cd, Ga, In, Pb, Sb, Se, Sn, Te and Tl) that enhance sensitivity, alleviate problems resulting from the complex solutions and produce acceptable precision. Platinum, Pd and Mo can be determined without matrix modification directly on the original unstripped extracts.

  20. Trace element analysis of extraterrestrial metal samples by inductively coupled plasma mass spectrometry: the standard solutions and digesting acids.

    PubMed

    Wang, Guiqin; Wu, Yangsiqian; Lin, Yangting

    2016-02-28

    Nearly 99% of the total content of extraterrestrial metals is composed of Fe and Ni, but with greatly variable trace element contents. The accuracy obtained in the inductively coupled plasma mass spectrometry (ICP-MS) analysis of solutions of these samples can be significantly influenced by matrix contents, polyatomic ion interference, and the concentrations of external standard solutions. An ICP-MS instrument (X Series 2) was used to determine 30 standard solutions with different concentrations of trace elements, and different matrix contents. Based on these measurements, the matrix effects were determined. Three iron meteorites were dissolved separately in aqua regia and HNO3. Deviations due to variation of matrix contents in the external standard solutions were evaluated and the analysis results of the two digestion methods for iron meteorites were assessed. Our results show obvious deviations due to unmatched matrix contents in the external standard solutions. Furthermore, discrepancy in the measurement of some elements was found between the sample solutions prepared with aqua regia and HNO3, due to loss of chloride during sample preparation and/or incomplete digestion of highly siderophile elements in iron meteorites. An accurate ICP-MS analysis method for extraterrestrial metal samples has been established using external standard solutions with matched matrix contents and digesting the samples with HNO3 and aqua regia. Using the data from this work, the Mundrabilla iron meteorite previously classified as IAB-ung is reclassified as IAB-MG. Copyright © 2016 John Wiley & Sons, Ltd.

  1. Payload specialist Reinhard Furrer show evidence of previous blood sampling

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Payload specialist Reinhard Furrer shows evidence of previous blood sampling while Wubbo J. Ockels, Dutch payload specialist (only partially visible), extends his right arm after a sample has been taken. Both men show bruises on their arms.

  2. Multiplexed droplet single-cell RNA-sequencing using natural genetic variation.

    PubMed

    Kang, Hyun Min; Subramaniam, Meena; Targ, Sasha; Nguyen, Michelle; Maliskova, Lenka; McCarthy, Elizabeth; Wan, Eunice; Wong, Simon; Byrnes, Lauren; Lanata, Cristina M; Gate, Rachel E; Mostafavi, Sara; Marson, Alexander; Zaitlen, Noah; Criswell, Lindsey A; Ye, Chun Jimmie

    2018-01-01

    Droplet single-cell RNA-sequencing (dscRNA-seq) has enabled rapid, massively parallel profiling of transcriptomes. However, assessing differential expression across multiple individuals has been hampered by inefficient sample processing and technical batch effects. Here we describe a computational tool, demuxlet, that harnesses natural genetic variation to determine the sample identity of each droplet containing a single cell (singlet) and detect droplets containing two cells (doublets). These capabilities enable multiplexed dscRNA-seq experiments in which cells from unrelated individuals are pooled and captured at higher throughput than in standard workflows. Using simulated data, we show that 50 single-nucleotide polymorphisms (SNPs) per cell are sufficient to assign 97% of singlets and identify 92% of doublets in pools of up to 64 individuals. Given genotyping data for each of eight pooled samples, demuxlet correctly recovers the sample identity of >99% of singlets and identifies doublets at rates consistent with previous estimates. We apply demuxlet to assess cell-type-specific changes in gene expression in 8 pooled lupus patient samples treated with interferon (IFN)-β and perform eQTL analysis on 23 pooled samples.

  3. Improving tritium exposure reconstructions using accelerator mass spectrometry

    PubMed Central

    Hunt, J. R.; Vogel, J. S.; Knezovich, J. P.

    2010-01-01

    Direct measurement of tritium atoms by accelerator mass spectrometry (AMS) enables rapid low-activity tritium measurements from milligram-sized samples and permits greater ease of sample collection, faster throughput, and increased spatial and/or temporal resolution. Because existing methodologies for quantifying tritium have some significant limitations, the development of tritium AMS has allowed improvements in reconstructing tritium exposure concentrations from environmental measurements and provides an important additional tool in assessing the temporal and spatial distribution of chronic exposure. Tritium exposure reconstructions using AMS were previously demonstrated for a tree growing on known levels of tritiated water and for trees exposed to atmospheric releases of tritiated water vapor. In these analyses, tritium levels were measured from milligram-sized samples with sample preparation times of a few days. Hundreds of samples were analyzed within a few months of sample collection and resulted in the reconstruction of spatial and temporal exposure from tritium releases. Although the current quantification limit of tritium AMS is not adequate to determine natural environmental variations in tritium concentrations, it is expected to be sufficient for studies assessing possible health effects from chronic environmental tritium exposure. PMID:14735274

  4. Detection of cytomegalovirus DNA in fecal samples as a method for CMV enterocolitis diagnosis after allogeneic stem cell transplantation.

    PubMed

    Zavrelova, Alzbeta; Radocha, Jakub; Pliskova, Lenka; Paterova, Pavla; Vejrazkova, Eva; Cyrany, Jiri; Gabalec, Filip; Podhola, Miroslav; Zak, Pavel

    2018-05-16

    Cytomegalovirus enterocolitis is a rare but potentially life threatening complication after allogeneic stem cell transplantation. Its early diagnosis and treatment are essential for a successful outcome. To determine the potential benefit of fecal CMV DNA detection in the diagnosis of CMV colitis among stem cell transplant recipients. Biopsies from the lower gastrointestinal tract, taken during 69 episodes of diarrhea, were compared with fecal samples previously examined for CMV DNA in 45 patients after allogeneic stem cell transplantation. Six confirmed cases of CMV colitis were observed, with 16 out of 69 (23%) fecal samples proving positive for CMV DNA. Only one positive sample correlated with histologically confirmed CMV colitis, and 15 samples were evaluated as false positive. These results provide a 16.7% sensitivity and 76.2% specificity in the diagnosis of CMV enterocolitis. The examination of fecal samples for the presence of CMV DNA has very low potential in the diagnosis of CMV enterocolitis after allogeneic stem cell transplantation; therefore, a biopsy of the gastrointestinal mucosa is still warranted for correct diagnosis.

  5. Precision and Accuracy of Analysis for Boron in ITP Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tovo, L.L.

    'Inductively Coupled Plasma Emission Spectroscopy (ICPES) has been used by the Analytical Development Section (ADS) to measure boron in catalytic tetraphenylboron decomposition studies performed by the Waste Processing Technology (WPT) section. Analysis of these samples is complicated due to the presence of high concentrations of sodium and organic compounds. Previously, we found signal suppression in samples analyzed "as received". We suspected that the suppression was due to the high organic concentration (up to 0.01 molar organic decomposition products) in the samples. When the samples were acid digested prior to analysis, the suppression was eliminated. The precision of the reported boronmore » concentration was estimated as 10 percent based on the known precision of the inorganic boron standard used for calibration and quality control check of the ICPES analysis. However, a precision better than 10 percent was needed to evaluate ITP process operating parameters. Therefore, the purpose of this work was (1) to measure, instead of estimating, the precision of the boron measurement on ITP samples and (2) to determine the optimum precision attainable with current instrumentation.'« less

  6. Self-irradiation damage to the local structure of plutonium and plutonium intermetallics

    NASA Astrophysics Data System (ADS)

    Booth, C. H.; Jiang, Yu; Medling, S. A.; Wang, D. L.; Costello, A. L.; Schwartz, D. S.; Mitchell, J. N.; Tobash, P. H.; Bauer, E. D.; McCall, S. K.; Wall, M. A.; Allen, P. G.

    2013-03-01

    The effect of self-irradiation damage on the local structure of δ-Pu, PuAl2, PuGa3, and other Pu intermetallics has been determined for samples stored at room temperature using the extended x-ray absorption fine-structure (EXAFS) technique. These measurements indicate that the intermetallic samples damage at a similar rate as indicated in previous studies of PuCoGa5. In contrast, δ-Pu data indicate a much slower damage accumulation rate. To explore the effect of storage temperature and possible room temperature annealing effects, we also collected EXAFS data on a δ-Pu sample that was held at less than 32 K for a two month period. This sample damaged much more quickly. In addition, the measurable damage was annealed out at above only 135 K. Data from samples of δ-Pu with different Ga concentrations and results on all samples collected from different absorption edges are also reported. These results are discussed in terms of the vibrational properties of the materials and the role of Ga in δ-Pu as a network former.

  7. Sociodemographic and psychiatric determinants of attrition in the Netherlands Study of Depression and Anxiety (NESDA).

    PubMed

    Lamers, Femke; Hoogendoorn, Adriaan W; Smit, Johannes H; van Dyck, Richard; Zitman, Frans G; Nolen, Willem A; Penninx, Brenda W

    2012-01-01

    Although attrition is inevitable in longitudinal epidemiological studies, psychiatric studies are thought to be especially sensitive to attrition. This study aimed to evaluate the sociodemographic and psychiatric determinants of attrition at 2-year follow-up in the Netherlands Study of Depression and Anxiety. Logistic regression was used to examine sociodemographic and psychiatric determinants of attrition and the influence of clinical psychiatric characteristics on attrition. In addition, differences in determinants between 3 types of attrition (refusal, noncontact, and not able to participate) were evaluated. The attrition rate at the 2-year follow-up assessment was 12.9% (385/2981), representing 6 deceased persons, 250 refusers, 51 noncontacts, and 78 persons unable to participate because of health reasons. Determinants of attrition were younger age, less years of education, not being of North European descent, being recruited in Amsterdam, no previous participation in research, and having major depressive disorder. Only the effects of age, sampling site, and previous participation in research differed between types of attrition. Furthermore, comorbid depressive and anxiety disorders and higher symptom severity were associated with attrition. In contrast to the view that psychiatric epidemiological research is more prone to high attrition rates, this study revealed a relatively low attrition rate. Furthermore, both sociodemographic and psychiatric variables were independent determinants of attrition. Oversampling of subgroups that are at higher risk of dropout may be advisable for future psychiatric cohort studies. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Beryllium abundances along the evolutionary sequence of the open cluster IC 4651 - A new test for hydrodynamical stellar models

    NASA Astrophysics Data System (ADS)

    Smiljanic, R.; Pasquini, L.; Charbonnel, C.; Lagarde, N.

    2010-02-01

    Context. Previous analyses of lithium abundances in main sequence and red giant stars have revealed the action of mixing mechanisms other than convection in stellar interiors. Beryllium abundances in stars with Li abundance determinations can offer valuable complementary information on the nature of these mechanisms. Aims: Our aim is to derive Be abundances along the whole evolutionary sequence of an open cluster. We focus on the well-studied open cluster IC 4651. These Be abundances are used with previously determined Li abundances, in the same sample stars, to investigate the mixing mechanisms in a range of stellar masses and evolutionary stages. Methods: Atmospheric parameters were adopted from a previous abundance analysis by the same authors. New Be abundances have been determined from high-resolution, high signal-to-noise UVES spectra using spectrum synthesis and model atmospheres. The careful synthetic modeling of the Be lines region is used to calculate reliable abundances in rapidly rotating stars. The observed behavior of Be and Li is compared to theoretical predictions from stellar models including rotation-induced mixing, internal gravity waves, atomic diffusion, and thermohaline mixing. Results: Beryllium is detected in all the main sequence and turn-off sample stars, both slow- and fast-rotating stars, including the Li-dip stars, but is not detected in the red giants. Confirming previous results, we find that the Li dip is also a Be dip, although the depletion of Be is more modest than for Li in the corresponding effective temperature range. For post-main-sequence stars, the Be dilution starts earlier within the Hertzsprung gap than expected from classical predictions, as does the Li dilution. A clear dispersion in the Be abundances is also observed. Theoretical stellar models including the hydrodynamical transport processes mentioned above are able to reproduce all the observed features well. These results show a good theoretical understanding of the Li and Be behavior along the color-magnitude diagram of this intermediate-age cluster for stars more massive than 1.2 M⊙. Based on observations made with the ESO VLT, at Paranal Observatory, under programs 065.L-0427 and 067.D-0126.Current address: European Southern Observatory, Karl-Schwarzschild-Str. 2, 85748 Garching bei München, Germany.

  9. Radionuclide transfer to wildlife at a 'Reference site' in the Chernobyl Exclusion Zone and resultant radiation exposures.

    PubMed

    Beresford, N A; Barnett, C L; Gashchak, S; Maksimenko, A; Guliaichenko, E; Wood, M D; Izquierdo, M

    2018-02-27

    This study addresses a significant data deficiency in the developing environmental protection framework of the International Commission on Radiological Protection, namely a lack of radionuclide transfer data for some of the Reference Animals and Plants (RAPs). It is also the first study that has sampled such a wide range of species (invertebrates, plants, amphibians and small mammals) from a single terrestrial site in the Chernobyl Exclusion Zone (CEZ). Samples were collected in 2014 from the 0.4 km 2 sampling site, located 5 km west of the Chernobyl Nuclear Power complex. We report radionuclide ( 137 Cs, 90 Sr, 241 Am and Pu-isotopes) and stable element concentrations in wildlife and soil samples and use these to determine whole organism-soil concentration ratios and absorbed dose rates. Increasingly, stable element analyses are used to provide transfer parameters for radiological models. The study described here found that for both Cs and Sr the transfer of the stable element tended to be lower than that of the radionuclide; this is the first time that this has been demonstrated for Sr, though it is in agreement with limited evidence previously reported for Cs. Studies reporting radiation effects on wildlife in the CEZ generally relate observations to ambient dose rates determined using handheld dose meters. For the first time, we demonstrate that ambient dose rates may underestimate the actual dose rate for some organisms by more than an order of magnitude. When reporting effects studies from the CEZ, it has previously been suggested that the area has comparatively low natural background dose rates. However, on the basis of data reported here, dose rates to wildlife from natural background radionuclides within the CEZ are similar to those in many areas of Europe. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. A prospective gating method to acquire a diverse set of free-breathing CT images for model-based 4DCT

    NASA Astrophysics Data System (ADS)

    O'Connell, D.; Ruan, D.; Thomas, D. H.; Dou, T. H.; Lewis, J. H.; Santhanam, A.; Lee, P.; Low, D. A.

    2018-02-01

    Breathing motion modeling requires observation of tissues at sufficiently distinct respiratory states for proper 4D characterization. This work proposes a method to improve sampling of the breathing cycle with limited imaging dose. We designed and tested a prospective free-breathing acquisition protocol with a simulation using datasets from five patients imaged with a model-based 4DCT technique. Each dataset contained 25 free-breathing fast helical CT scans with simultaneous breathing surrogate measurements. Tissue displacements were measured using deformable image registration. A correspondence model related tissue displacement to the surrogate. Model residual was computed by comparing predicted displacements to image registration results. To determine a stopping criteria for the prospective protocol, i.e. when the breathing cycle had been sufficiently sampled, subsets of N scans where 5  ⩽  N  ⩽  9 were used to fit reduced models for each patient. A previously published metric was employed to describe the phase coverage, or ‘spread’, of the respiratory trajectories of each subset. Minimum phase coverage necessary to achieve mean model residual within 0.5 mm of the full 25-scan model was determined and used as the stopping criteria. Using the patient breathing traces, a prospective acquisition protocol was simulated. In all patients, phase coverage greater than the threshold necessary for model accuracy within 0.5 mm of the 25 scan model was achieved in six or fewer scans. The prospectively selected respiratory trajectories ranked in the (97.5  ±  4.2)th percentile among subsets of the originally sampled scans on average. Simulation results suggest that the proposed prospective method provides an effective means to sample the breathing cycle with limited free-breathing scans. One application of the method is to reduce the imaging dose of a previously published model-based 4DCT protocol to 25% of its original value while achieving mean model residual within 0.5 mm.

  11. Constant-pressure nested sampling with atomistic dynamics

    NASA Astrophysics Data System (ADS)

    Baldock, Robert J. N.; Bernstein, Noam; Salerno, K. Michael; Pártay, Lívia B.; Csányi, Gábor

    2017-10-01

    The nested sampling algorithm has been shown to be a general method for calculating the pressure-temperature-composition phase diagrams of materials. While the previous implementation used single-particle Monte Carlo moves, these are inefficient for condensed systems with general interactions where single-particle moves cannot be evaluated faster than the energy of the whole system. Here we enhance the method by using all-particle moves: either Galilean Monte Carlo or the total enthalpy Hamiltonian Monte Carlo algorithm, introduced in this paper. We show that these algorithms enable the determination of phase transition temperatures with equivalent accuracy to the previous method at 1 /N of the cost for an N -particle system with general interactions, or at equal cost when single-particle moves can be done in 1 /N of the cost of a full N -particle energy evaluation. We demonstrate this speed-up for the freezing and condensation transitions of the Lennard-Jones system and show the utility of the algorithms by calculating the order-disorder phase transition of a binary Lennard-Jones model alloy, the eutectic of copper-gold, the density anomaly of water, and the condensation and solidification of bead-spring polymers. The nested sampling method with all three algorithms is implemented in the pymatnest software.

  12. Slow histidine H/D exchange protocol for thermodynamic analysis of protein folding and stability using mass spectrometry.

    PubMed

    Tran, Duc T; Banerjee, Sambuddha; Alayash, Abdu I; Crumbliss, Alvin L; Fitzgerald, Michael C

    2012-02-07

    Described here is a mass spectrometry-based protocol to study the thermodynamic stability of proteins and protein-ligand complexes using the chemical denaturant dependence of the slow H/D exchange reaction of the imidazole C(2) proton in histidine side chains. The protocol is developed using several model protein systems including: ribonuclease (Rnase) A, myoglobin, bovine carbonic anhydrase (BCA) II, hemoglobin (Hb), and the hemoglobin-haptoglobin (Hb-Hp) protein complex. Folding free energies consistent with those previously determined by other more conventional techniques were obtained for the two-state folding proteins, Rnase A and myoglobin. The protocol successfully detected a previously observed partially unfolded intermediate stabilized in the BCA II folding/unfolding reaction, and it could be used to generate a K(d) value of 0.24 nM for the Hb-Hp complex. The compatibility of the protocol with conventional mass spectrometry-based proteomic sample preparation and analysis methods was also demonstrated in an experiment in which the protocol was used to detect the binding of zinc to superoxide dismutase in the yeast cell lysate sample. The yeast cell sample analyses also helped define the scope of the technique, which requires the presence of globally protected histidine residues in a protein's three-dimensional structure for successful application. © 2011 American Chemical Society

  13. Recent sequence variation in probe binding site affected detection of respiratory syncytial virus group B by real-time RT-PCR.

    PubMed

    Kamau, Everlyn; Agoti, Charles N; Lewa, Clement S; Oketch, John; Owor, Betty E; Otieno, Grieven P; Bett, Anne; Cane, Patricia A; Nokes, D James

    2017-03-01

    Direct immuno-fluorescence test (IFAT) and multiplex real-time RT-PCR have been central to RSV diagnosis in Kilifi, Kenya. Recently, these two methods showed discrepancies with an increasing number of PCR undetectable RSV-B viruses. Establish if mismatches in the primer and probe binding sites could have reduced real-time RT-PCR sensitivity. Nucleoprotein (N) and glycoprotein (G) genes were sequenced for real-time RT-PCR positive and negative samples. Primer and probe binding regions in N gene were checked for mismatches and phylogenetic analyses done to determine molecular epidemiology of these viruses. New primers and probe were designed and tested on the previously real-time RT-PCR negative samples. N gene sequences revealed 3 different mismatches in the probe target site of PCR negative, IFAT positive viruses. The primers target sites had no mismatches. Phylogenetic analysis of N and G genes showed that real-time RT-PCR positive and negative samples fell into distinct clades. Newly designed primers-probe pair improved detection and recovered previous PCR undetectable viruses. An emerging RSV-B variant is undetectable by a quite widely used real-time RT-PCR assay due to polymorphisms that influence probe hybridization affecting PCR accuracy. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Detection of feral transgenic oilseed rape with multiple-herbicide resistance in Japan.

    PubMed

    Aono, Mitsuko; Wakiyama, Seiji; Nagatsu, Masato; Nakajima, Nobuyoshi; Tamaoki, Masanori; Kubo, Akihiro; Saji, Hikaru

    2006-01-01

    Repeated monitoring for escaped transgenic crop plants is sometimes necessary, especially in cases when the crop has not been approved for release into the environment. Transgenic oilseed rape (Brassica napus) was detected along roadsides in central Japan in a previous study. The goal of the current study was to monitor the distribution of transgenic oilseed rape and occurrence of hybridization of transgenic B. napus with feral populations of its closely related species (B. rapa and B. juncea) in the west of Japan in 2005. The progenies of 50 B. napus, 82 B. rapa and 283 B. juncea maternal plants from 95 sampling sites in seven port areas were screened for herbicide-resistance. Transgenic herbicide-resistant seeds were detected from 12 B. napus maternal plants growing at seven sampling sites in two port areas. A portion of the progeny from two transgenic B. napus plants had both glyphosate-resistance and glufosinate-resistance transgenes. Therefore, two types of transgenic B. napus plants are likely to have outcrossed with each other, since the double-herbicide-resistant transgenic strain of oilseed rape has not been developed intentionally for commercial purposes. As found in the previous study, no transgenic seeds were detected from B. rapa or B. juncea, and more extensive sampling is needed to determine whether introgression into these wild species has occurred.

  15. (210)Polonium and (210)lead content of marine birds from Southeastern Brazil.

    PubMed

    Godoy, José Marcus; Siciliano, Salvatore; de Carvalho, Zenildo Lara; Tavares, Davi C; de Moura, Jaílson Fulgencio; Godoy, Maria Luiza D P

    2014-09-01

    In this study, we report the (210)Po and (210)Pb concentrations of bone, muscle and liver samples that were obtained from twelve different marine bird species stranded on beaches in the central-north region of Rio de Janeiro State. Both radionuclides were highly concentrated in the liver samples; however, the lowest mean (210)Po/(210)Pb activity ratio (1.3) was observed in bones compared with liver and muscle (16.8 and 13.8, respectively). Among the species that were studied, Fregata magnificens, with a diet based exclusively on fish, had the lowest (210)Pb and (210)Po concentrations and the lowest (210)Po/(210)Pb activity ratio. The (210)Po concentrations in Puffinus spp. liver samples followed a log-normal distribution, with a geometric mean of 300 Bq kg(-1)wet weight. Only two references pertaining to (210)Po in marine birds were found in a Web of Science search of the literature, and each study reported a different concentration value. The values determined in this experiment are consistent with those in one of the previous studies, which also included one of the species studied in this work. No values for (210)Pb in marine birds have been published previously. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Trace elements and organic compounds in bed sediment from selected streams in southern Louisiana, 1998

    USGS Publications Warehouse

    Skrobialowski, Stanley C.

    2002-01-01

    Bed-sediment samples from 21 selected streams in southern Louisiana were collected and analyzed for the presence of trace elements and organic compounds during 1998 as part of the U.S. Geological Survey National Water-Quality Assessment Program. Concentrations of selected trace elements and organic compounds were compared on the basis of sediment-quality criteria, land use, and grain size; concentrations of selected trace elements also were compared with concentrations from previous studies. Concentrations of seven selected trace elements and 21 organic compounds were evaluated with sediment-quality criteria established by the Canadian Council of Ministers of the Environment. Concentrations of selected trace elements and organic compounds were highest at sites draining urban and agricultural areas and may result from cumulative effects of relatively high percentages of fine-grained material, iron, and organic material. Concentrations exceeding sediment-quality criteria for the protection of aquatic life occurred most frequently at Bayou Grosse Tete at Rosedale and Bayou Lafourche below weir at Thibodaux. Exceedance of Interim Sediment Quality Guidelines occurred most frequently for arsenic and chromium. Trace-element concentrations in fine-grained samples were compared with concentrations in bulk samples and were determined to be significantly different, and concentrations were generally higher in finegrained sediment. Shapiro-Wilk, paired t-test, and Wilcoxon rank sum statistical procedures, with an alpha of 0.05, were used to compare concentrations of 21 trace elements, total organic carbon, and total carbon in finegrained and bulk sediment samples for 19 sites. Significant differences were determined between fine-grained and bulk sediment samples for aluminum, barium, beryllium, chromium, copper, iron, lithium, nickel, phosphorus, selenium, titanium, and zinc concentrations. Of 133 paired concentrations, 69 percent were greater in fine-grained samples, and 23 percent were greater in bulk samples. Comparisons with data from previous studies indicate increases by more than 20 percent in concentrations of antimony at Bayou Lafourche below weir at Thibodaux, arsenic and chromium at Tickfaw River at Liverpool, lead at Bayou Lafourche below weir at Thibodaux, and zinc at Bayou Lafourche below weir at Thibodaux and Vermilion River at Perry. Historic comparisons also indicate decreases by more than 20 percent in concentrations of chromium at Bayou des Cannes near Eunice and mercury at Mermentau River at Mermentau.

  17. A simple field kit for the determination of drug susceptibility in Plasmodium falciparum.

    PubMed

    Nguyen-Dinh, P; Magloire, R; Chin, W

    1983-05-01

    A field kit has been developed which greatly simplifies the performance of the 48-hour in vitro test for drug resistance in Plasmodium falciparum. The kit uses an easily reconstituted lyophilized culture medium, and requires only a fingerprick blood sample. In parallel tests with 13 isolates of P. falciparum in Haiti, the new technique had a success rate equal to that of the previously described method, with comparable results in terms of parasite susceptibility in vitro to chloroquine and pyrimethamine.

  18. Use of 16S rRNA Sequencing for Identification of Actinobacillus ureae Isolated from a Cerebrospinal Fluid Sample

    PubMed Central

    Whitelaw, A. C.; Shankland, I. M.; Elisha, B. G.

    2002-01-01

    Actinobacillus ureae, previously Pasteurella ureae, has on rare occasions been described as a cause of human infection. Owing to its rarity, it may not be easily identified in clinical microbiology laboratories by standard tests. This report describes a patient with acute bacterial meningitis due to A. ureae. The identity of the isolate was determined by means of DNA sequence analysis of a portion of the 16S rRNA gene. PMID:11825992

  19. A survey of fur mites in domestic rabbits.

    PubMed

    Flatt, R E; Wiemers, J

    1976-10-01

    A survey of six commercial rabbit colonies was conducted to determine the prevalence of the mite Cheyletiella parasitvorax. This mite was present in all six colonies, and 43.2% of 220 rabbits examined were infested. Listrophorus gibbus, reported only once previously in domestic rabbits in the United States, was found in four of the six colonies, and in 7.3% of the 220 rabbits examined. Non-parasitic mites were found in 3.2% of the samples. Over 50% of the rabbits examined had inapparent mite infestations.

  20. Flash melting of tantalum in a diamond cell to 85 GPa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karandikar, Amol; Boehler, Reinhard

    2016-02-09

    Here, we demonstrate a new level of precision in measuring melting temperatures at high pressure using laser flash-heating followed by Scanning Electron Microscopy and Focused Ion Beam Milling. Furthermore, the new measurements on tantalum put unprecedented constraints on its highly debated melting slope, calling for a reevaluation of theoretical, shock compression and diamond cell approaches to determine melting at high pressure. X-ray analysis of the recovered samples confirmed the absence of chemical reactions, which likely played a significant role in previous experiments.

Top