Sample records for samples results demonstrate

  1. Test and evaluation of Apollo 14 composite casting demonstration specimens and flight and control samples

    NASA Technical Reports Server (NTRS)

    Fabiniak, R. C.; Fabiniak, T. J.

    1971-01-01

    The results of experiments 1, 2, and 10 of the Apollo 14 composite casting demonstration are discussed. The purpose of the demonstration, with regard to samples 1 and 2, was to obtain preliminary data on the liquid phase sintering process in a weightless environment. With regard to sample 10, the purpose was to obtain preliminary information on how to achieve uniform dispersion of dense particles on a metal matrix by employing shaking modes or forces in the system when the metal matrix is molten. Results of the demonstrations were interpreted in a quantitative and qualitative manner. For experiment 1 it was found that the tungsten particles were redistributed more uniformly in the flight sample than in the control sample. Experiment 2 results indicate that complete melting may not have occured and thus a high degree of significance cannot be associated with the qualitative results relating to particle redistribution data. The particle-matrix system of experiment 10 was found to be nonwetting.

  2. INTERIM REPORT ON THE EVOLUTION AND ...

    EPA Pesticide Factsheets

    A demonstration of screening technologies for determining the presence of dioxin and dioxin-like compounds in soil and sediment was conducted under the U.S. Environmental Protection Agency's(EPA's) Superfund Innovative Technology Evaluation Program in Saginaw, Michigan in 2004. The objectives of the demonstration included evaluating each participating technology's accuracy, precision, sensitivity, sample throughput, tendency for matrix effects, and cost. The test also included an assessment of how well the technology's results compared to those generated by established laboratory methods using high-resolution mass spectrometry (HRMS). The demonstration objectives were accomplished by evaluating the results generated by each technology from 209 soil, sediment, and extract samples. The test samples included performance evaluation (PE) samples (i.e., contaminant concentrations were certified or the samples were spiked with known contaminants) and environmental samples collected from 10 different sampling locations. The PE and environmental samples were distributed to the technology developers in blind, random order. One of the participants in the original SITE demonstration was Hybrizyme Corporation, which demonstrated the use of the AhRC PCR Kit. The AhRC PCR Kit was a technology that reported the concentration of aryl hydrocarbon receptor (AhR) binding compounds in a sample, with units reported as Ah Receptor Binding Units (AhRBU). At the time of the original dem

  3. Results and analysis of saltstone cores taken from saltstone disposal unit cell 2A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reigel, M. M.; Hill, K. A.

    2016-03-01

    As part of an ongoing Performance Assessment (PA) Maintenance Plan, Savannah River Remediation (SRR) has developed a sampling and analyses strategy to facilitate the comparison of field-emplaced samples (i.e., saltstone placed and cured in a Saltstone Disposal Unit (SDU)) with samples prepared and cured in the laboratory. The primary objectives of the Sampling and Analyses Plan (SAP) are; (1) to demonstrate a correlation between the measured properties of laboratory-prepared, simulant samples (termed Sample Set 3), and the field-emplaced saltstone samples (termed Sample Set 9), and (2) to validate property values assumed for the Saltstone Disposal Facility (SDF) PA modeling. Themore » analysis and property data for Sample Set 9 (i.e. six core samples extracted from SDU Cell 2A (SDU2A)) are documented in this report, and where applicable, the results are compared to the results for Sample Set 3. Relevant properties to demonstrate the aforementioned objectives include bulk density, porosity, saturated hydraulic conductivity (SHC), and radionuclide leaching behavior.« less

  4. Immediate drop on demand technology (I-DOT) coupled with mass spectrometry via an open port sampling interface.

    PubMed

    Van Berkel, Gary J; Kertesz, Vilmos; Boeltz, Harry

    2017-11-01

    The aim of this work was to demonstrate and evaluate the analytical performance of coupling the immediate drop on demand technology to a mass spectrometer via the recently introduced open port sampling interface and ESI. Methodology & results: A maximum sample analysis throughput of 5 s per sample was demonstrated. Signal reproducibility was 10% or better as demonstrated by the quantitative analysis of propranolol and its stable isotope-labeled internal standard propranolol-d7. The ability of the system to multiply charge and analyze macromolecules was demonstrated using the protein cytochrome c. This immediate drop on demand technology/open port sampling interface/ESI-MS combination allowed for the quantitative analysis of relatively small mass analytes and was used for the identification of macromolecules like proteins.

  5. The effect of sampling techniques used in the multiconfigurational Ehrenfest method

    NASA Astrophysics Data System (ADS)

    Symonds, C.; Kattirtzi, J. A.; Shalashilin, D. V.

    2018-05-01

    In this paper, we compare and contrast basis set sampling techniques recently developed for use in the ab initio multiple cloning method, a direct dynamics extension to the multiconfigurational Ehrenfest approach, used recently for the quantum simulation of ultrafast photochemistry. We demonstrate that simultaneous use of basis set cloning and basis function trains can produce results which are converged to the exact quantum result. To demonstrate this, we employ these sampling methods in simulations of quantum dynamics in the spin boson model with a broad range of parameters and compare the results to accurate benchmarks.

  6. The effect of sampling techniques used in the multiconfigurational Ehrenfest method.

    PubMed

    Symonds, C; Kattirtzi, J A; Shalashilin, D V

    2018-05-14

    In this paper, we compare and contrast basis set sampling techniques recently developed for use in the ab initio multiple cloning method, a direct dynamics extension to the multiconfigurational Ehrenfest approach, used recently for the quantum simulation of ultrafast photochemistry. We demonstrate that simultaneous use of basis set cloning and basis function trains can produce results which are converged to the exact quantum result. To demonstrate this, we employ these sampling methods in simulations of quantum dynamics in the spin boson model with a broad range of parameters and compare the results to accurate benchmarks.

  7. Imaging systems and algorithms to analyze biological samples in real-time using mobile phone microscopy.

    PubMed

    Shanmugam, Akshaya; Usmani, Mohammad; Mayberry, Addison; Perkins, David L; Holcomb, Daniel E

    2018-01-01

    Miniaturized imaging devices have pushed the boundaries of point-of-care imaging, but existing mobile-phone-based imaging systems do not exploit the full potential of smart phones. This work demonstrates the use of simple imaging configurations to deliver superior image quality and the ability to handle a wide range of biological samples. Results presented in this work are from analysis of fluorescent beads under fluorescence imaging, as well as helminth eggs and freshwater mussel larvae under white light imaging. To demonstrate versatility of the systems, real time analysis and post-processing results of the sample count and sample size are presented in both still images and videos of flowing samples.

  8. Imaging systems and algorithms to analyze biological samples in real-time using mobile phone microscopy

    PubMed Central

    Mayberry, Addison; Perkins, David L.; Holcomb, Daniel E.

    2018-01-01

    Miniaturized imaging devices have pushed the boundaries of point-of-care imaging, but existing mobile-phone-based imaging systems do not exploit the full potential of smart phones. This work demonstrates the use of simple imaging configurations to deliver superior image quality and the ability to handle a wide range of biological samples. Results presented in this work are from analysis of fluorescent beads under fluorescence imaging, as well as helminth eggs and freshwater mussel larvae under white light imaging. To demonstrate versatility of the systems, real time analysis and post-processing results of the sample count and sample size are presented in both still images and videos of flowing samples. PMID:29509786

  9. TECHNOLOGIES FORM MONITORING AND ...

    EPA Pesticide Factsheets

    A demonstration of technologies for determining the presence of dioxin and dioxin-like compounds in soil and sediment was conducted under EPA's Superfund Innovative Technology Evaluation Program in Saginaw, Michigan in April 2004. This report describes the evaluation of Wako Pure Chemical Industries's Dioxin ELISA Kit. The kit is an immunoassay technique that reports toxicity equivalents (TEQ) of dioxin/furans. The sample units are in pg/g 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) equivalents (EQ). The technology results were compared to high resolution mass spectrometry (HRMS) TEQ results generated using EPA Method 1613B.The Wako results were biased both positively and negatively relative to HRMS results. The technologys estimated method detection limit was 83-201 pg/g 2,3,7,8-TCDD EQ, but this should be considered a rough estimate. Results from this demonstration suggest that the Wako kit could be an effective screening tool for determining sample results above and below 20 pg/g TEQ, and even more effective as a screen for samples above and below 50 pg/g TEQ, particularly considering the cost to analyze the 209 demonstration samples was significantly less than that of the reference laboratory ($150,294 vs. $213,580), and all samples were analyzed on-site in 9 days (in comparison to the reference laboratory which took 8 months). The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented per

  10. Direct detection of Mycobacterium avium in environmental water and scale samples by loop-mediated isothermal amplification.

    PubMed

    Nishiuchi, Yukiko; Tamaru, Aki; Suzuki, Yasuhiko; Kitada, Seigo; Maekura, Ryoji; Tateishi, Yoshitaka; Niki, Mamiko; Ogura, Hisashi; Matsumoto, Sohkichi

    2014-06-01

    We previously demonstrated the colonization of Mycobacterium avium complex in bathrooms by the conventional culture method. In the present study, we aimed to directly detect M. avium organisms in the environment using loop-mediated isothermal amplification (LAMP), and to demonstrate the efficacy of LAMP by comparing the results with those obtained by culture. Our data showed that LAMP analysis has detection limits of 100 fg DNA/reaction for M. avium. Using an FTA(®) elute card, DNA templates were extracted from environmental samples from bathrooms in the residences of 29 patients with pulmonary M. avium disease. Of the 162 environmental samples examined, 143 (88%) showed identical results by both methods; 20 (12%) and 123 (76%) samples were positive and negative, respectively, for M. avium. Of the remaining 19 samples (12%), seven (5%) and 12 (7%) samples were positive by the LAMP and culture methods, respectively. All samples that contained over 20 colony forming units/primary isolation plate, as measured by the culture method, were also positive by the LAMP method. Our data demonstrate that the combination of the FTA elute card and LAMP can facilitate prompt detection of M. avium in the environment.

  11. Nanoindentation and the micromechanics of Van Gogh oil paints

    NASA Astrophysics Data System (ADS)

    Salvant, Johanna; Barthel, Etienne; Menu, Michel

    2011-08-01

    Understanding the mechanical properties of ancient paintings is a major issue for conservation and restoration. One strategy is to measure the mechanical properties of reconstructed paints: however, the aging process is poorly known, so it is also desirable to measure mechanical properties directly on ancient paint samples. Using nanoindentation, we have characterized submillimetric samples recovered from restoration of two Van Gogh paintings and compared the results with reconstructed paint samples. We demonstrate that the reduced modulus and hardness of historical paints can be measured at a very local scale, even differentiating between each paint layer. Our reconstructed paint samples exhibit elastic moduli comparable to values of the literature, but the values measured on the two 19th century paint samples are found to be significantly larger. Similarly, the compositional dependence of the elastic modulus is consistent with literature results for our reconstructed samples while our preliminary results for ancient samples do not readily fall into the same pattern. These results all point out to a significant impact of long term aging, in a manner which is difficult to predict in our present state of understanding. They demonstrate that nanoindentation is a very adequate tool to improve our knowledge of art paint mechanics and aging.

  12. Proof of concept: preimplantation genetic screening without embryo biopsy through analysis of cell-free DNA in spent embryo culture media.

    PubMed

    Shamonki, Mousa I; Jin, Helen; Haimowitz, Zachary; Liu, Lian

    2016-11-01

    To assess whether preimplantation genetic screening (PGS) is possible by testing for free embryonic DNA in spent IVF media from embryos undergoing trophectoderm biopsy. Prospective cohort analysis. Academic fertility center. Seven patients undergoing IVF and 57 embryos undergoing trophectoderm biopsy for PGS. On day 3 of development, each embryo was placed in a separate media droplet. All biopsied embryos received a PGS result by array comparative genomic hybridization. Preimplantation genetic screening was performed on amplified DNA extracted from media and results were compared with PGS results for the corresponding biopsy. [1] Presence of DNA in spent IVF culture media. [2] Correlation between genetic screening result from spent media and corresponding biopsy. Fifty-five samples had detectable DNA ranging from 2-642 ng/μL after a 2-hour amplification. Six samples with the highest DNA levels underwent PGS, rendering one result with a derivative log ratio SD (DLRSD) of <0.85 (a quality control metric of oligonucleotide array comparative genomic hybridization). The fluid sample and trophectoderm results were identical demonstrating (45XY, -13). Three samples were reamplified 1 hour later and tested showing improving DLRSD. One of the three samples with a DLRSD of 0.85 demonstrated (46XY), consistent with the biopsy. Overnight DNA amplification showed DNA in all samples. We demonstrate two novel findings: the presence of free embryonic DNA in spent media and a result that is consistent with trophectoderm biopsy. Improvements in DNA collection, amplification, and testing may allow for PGS without biopsy in the future. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  13. Spin Hall magnetoresistance in CoFe 2O 4/Pt films

    DOE PAGES

    Wu, Hao; Qintong, Zhang; Caihua, Wan; ...

    2015-05-13

    Pulse laser deposition and magnetron sputtering techniques have been employed to prepare MgO(001)//CoFe 2O 4/Pt samples. Cross section transmission electron microscope results prove that the CoFe 2O 4 film epitaxially grew along (001) direction. X-ray magnetic circular dichroism results show that magnetic proximity effect in this sample is negligible. Magnetoresistance (MR) properties confirm that spin Hall MR (SMR) dominates in this system. Spin Hall effect-induced anomalous Hall voltage was also observed in this sample. Lastly, these results not only demonstrate the universality of SMR effect but also demonstrate the utility in spintronics of CoFe 2O 4 as a new typemore » of magnetic insulator.« less

  14. HYPERSAMP - HYPERGEOMETRIC ATTRIBUTE SAMPLING SYSTEM BASED ON RISK AND FRACTION DEFECTIVE

    NASA Technical Reports Server (NTRS)

    De, Salvo L. J.

    1994-01-01

    HYPERSAMP is a demonstration of an attribute sampling system developed to determine the minimum sample size required for any preselected value for consumer's risk and fraction of nonconforming. This statistical method can be used in place of MIL-STD-105E sampling plans when a minimum sample size is desirable, such as when tests are destructive or expensive. HYPERSAMP utilizes the Hypergeometric Distribution and can be used for any fraction nonconforming. The program employs an iterative technique that circumvents the obstacle presented by the factorial of a non-whole number. HYPERSAMP provides the required Hypergeometric sample size for any equivalent real number of nonconformances in the lot or batch under evaluation. Many currently used sampling systems, such as the MIL-STD-105E, utilize the Binomial or the Poisson equations as an estimate of the Hypergeometric when performing inspection by attributes. However, this is primarily because of the difficulty in calculation of the factorials required by the Hypergeometric. Sampling plans based on the Binomial or Poisson equations will result in the maximum sample size possible with the Hypergeometric. The difference in the sample sizes between the Poisson or Binomial and the Hypergeometric can be significant. For example, a lot size of 400 devices with an error rate of 1.0% and a confidence of 99% would require a sample size of 400 (all units would need to be inspected) for the Binomial sampling plan and only 273 for a Hypergeometric sampling plan. The Hypergeometric results in a savings of 127 units, a significant reduction in the required sample size. HYPERSAMP is a demonstration program and is limited to sampling plans with zero defectives in the sample (acceptance number of zero). Since it is only a demonstration program, the sample size determination is limited to sample sizes of 1500 or less. The Hypergeometric Attribute Sampling System demonstration code is a spreadsheet program written for IBM PC compatible computers running DOS and Lotus 1-2-3 or Quattro Pro. This program is distributed on a 5.25 inch 360K MS-DOS format diskette, and the program price includes documentation. This statistical method was developed in 1992.

  15. Solar-thermal complex sample processing for nucleic acid based diagnostics in limited resource settings

    PubMed Central

    Gumus, Abdurrahman; Ahsan, Syed; Dogan, Belgin; Jiang, Li; Snodgrass, Ryan; Gardner, Andrea; Lu, Zhengda; Simpson, Kenneth; Erickson, David

    2016-01-01

    The use of point-of-care (POC) devices in limited resource settings where access to commonly used infrastructure, such as water and electricity, can be restricted represents simultaneously one of the best application fits for POC systems as well as one of the most challenging places to deploy them. Of the many challenges involved in these systems, the preparation and processing of complex samples like stool, vomit, and biopsies are particularly difficult due to the high number and varied nature of mechanical and chemical interferents present in the sample. Previously we have demonstrated the ability to use solar-thermal energy to perform PCR based nucleic acid amplifications. In this work demonstrate how the technique, using similar infrastructure, can also be used to perform solar-thermal based sample processing system for extracting and isolating Vibrio Cholerae nucleic acids from fecal samples. The use of opto-thermal energy enables the use of sunlight to drive thermal lysing reactions in large volumes without the need for external electrical power. Using the system demonstrate the ability to reach a 95°C threshold in less than 5 minutes and maintain a stable sample temperature of +/− 2°C following the ramp up. The system is demonstrated to provide linear results between 104 and 108 CFU/mL when the released nucleic acids were quantified via traditional means. Additionally, we couple the sample processing unit with our previously demonstrated solar-thermal PCR and tablet based detection system to demonstrate very low power sample-in-answer-out detection. PMID:27231636

  16. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Rigaku ZSX Mini II (ZSX Mini II) XRF Services x-ray fluorescence (XRF) analyzer was demon-strated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the ZSX Mini II analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the ZSX Mini II analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element con

  17. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Rontec PicoTAX x-ray fluorescence (XRF) analyzer was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the PicoTAX analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the PicoTAX analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element concentrations. Accuracy was assessed by c

  18. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Niton XLt 700 Series (XLt) XRF Services x-ray fluorescence (XRF) analyzer was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the XLt analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the XLt analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element concentrations. Accuracy

  19. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Oxford ED2000 x-ray fluorescence (XRF) analyzer was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the ED2000 analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the ED2000 analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element concentrations. Accuracy was assessed by com

  20. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Innov-X XT400 Series (XT400) x-ray fluorescence (XRF) analyzer was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the XT400 analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the XT400 analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element concentrations. Accuracy was as

  1. TECHNOLOGIES FOR MONITORING AND MEASUREMENT ...

    EPA Pesticide Factsheets

    A demonstration of technologies for determining the presence of dioxin and dioxin-like compounds in soil and sediment was conducted under EPA's Superfund Innovative Technology Evaluation Program in Saginaw, Michigan in April 2004. This report describes the performance evaluation of CAPE Technologies DF-1 Dioxin/Furan and PCB TEQ Immunoassay Kits. The kits are immunoassay techniques that report the total toxicity equivalents (TEQ) of dioxin/furans and polychlorinated biphenyls (PCBs. The technology results were compared to high resolution mass spectrometry TEQ results generated using EPA Methods 1613B and 1668A.The CAPE Technologies kits generally reported data higher than the certified PE and reference laboratory values. The technologys estimated MDL was 12 to 33 pg/g TEQ. Results from this demonstration suggest that the CAPE Technologies kits could be an effective screening tool for determining sample results above and below 20 pg/g TEQ and even more effective as a screen for sample above and below 50 pg/g TEQ, particularly considering that both the cost ($59,234 vs. $398,029) and the time (3 weeks vs. 8 months) to analyze the 209 demonstration samples were significantly less than those of the reference laboratory. The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented performance and cost data obtained from field demonstrations.

  2. A real time metabolomic profiling approach to detecting fish fraud using rapid evaporative ionisation mass spectrometry.

    PubMed

    Black, Connor; Chevallier, Olivier P; Haughey, Simon A; Balog, Julia; Stead, Sara; Pringle, Steven D; Riina, Maria V; Martucci, Francesca; Acutis, Pier L; Morris, Mike; Nikolopoulos, Dimitrios S; Takats, Zoltan; Elliott, Christopher T

    2017-01-01

    Fish fraud detection is mainly carried out using a genomic profiling approach requiring long and complex sample preparations and assay running times. Rapid evaporative ionisation mass spectrometry (REIMS) can circumvent these issues without sacrificing a loss in the quality of results. To demonstrate that REIMS can be used as a fast profiling technique capable of achieving accurate species identification without the need for any sample preparation. Additionally, we wanted to demonstrate that other aspects of fish fraud other than speciation are detectable using REIMS. 478 samples of five different white fish species were subjected to REIMS analysis using an electrosurgical knife. Each sample was cut 8-12 times with each one lasting 3-5 s and chemometric models were generated based on the mass range m/z 600-950 of each sample. The identification of 99 validation samples provided a 98.99% correct classification in which species identification was obtained near-instantaneously (≈ 2 s) unlike any other form of food fraud analysis. Significant time comparisons between REIMS and polymerase chain reaction (PCR) were observed when analysing 6 mislabelled samples demonstrating how REIMS can be used as a complimentary technique to detect fish fraud. Additionally, we have demonstrated that the catch method of fish products is capable of detection using REIMS, a concept never previously reported. REIMS has been proven to be an innovative technique to help aid the detection of fish fraud and has the potential to be utilised by fisheries to conduct their own quality control (QC) checks for fast accurate results.

  3. Results From The Salt Disposition Project Next Generation Solvent Demonstration Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, T. B.; Fondeur, F. F.; Taylor-Pashow, K. M.L.

    2014-04-02

    Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), Caustic Wash Tank (CWT) and Solvent Hold Tank (SHT) samples were taken throughout the Next Generation Solvent (NGS) Demonstration Plan. These samples were analyzed and the results are reported. SHT: The solvent behaved as expected, with no bulk changes in the composition over time, with the exception of the TOA and TiDG. The TiDG depletion is higher than expected, and consideration must be taken on the required rate of replenishment. Monthly sampling of the SHT is warranted. If possible, additional SHT samples for TiDG analysis (only) would help SRNLmore » refine the TiDG degradation model. CWT: The CWT samples show the expected behavior in terms of bulk chemistry. The 137Cs deposited into the CWT varies somewhat, but generally appears to be lower than during operations with the BOBCalix solvent. While a few minor organic components were noted to be present in the Preliminary sample, at this time these are thought to be artifacts of the sample preparation or may be due to the preceding solvent superwash. DSSHT: The DSSHT samples show the predicted bulk chemistry, although they point towards significant dilution at the front end of the Demonstration. The 137Cs levels in the DSSHT are much lower than during the BOBCalix operations, which is the expected observation. SEHT: The SEHT samples represent the most different output of all four of the outputs from MCU. While the bulk chemistry is as expected, something is causing the pH of the SEHT to be higher than what would be predicted from a pure stream of 0.01 M boric acid. There are several possible different reasons for this, and SRNL is in the process of investigating. Other than the pH issue, the SEHT is as predicted. In summary, the NGS Demonstration Plan samples indicate that the MCU system, with the Blend Solvent, is operating as expected. The only issue of concern regards the pH of the SEHT, and SRNL is in the process of investigating this. SRNL results support the transition to routine operations.« less

  4. Harmonisation of seven common enzyme results through EQA.

    PubMed

    Weykamp, Cas; Franck, Paul; Gunnewiek, Jacqueline Klein; de Jonge, Robert; Kuypers, Aldy; van Loon, Douwe; Steigstra, Herman; Cobbaert, Christa

    2014-11-01

    Equivalent results between different laboratories enable optimal patient care and can be achieved with harmonisation. We report on EQA-initiated national harmonisation of seven enzymes using commutable samples. EQA samples were prepared from human serum spiked with human recombinant enzymes. Target values were assigned with the IFCC Reference Measurement Procedures. The same samples were included at four occasions in the EQA programmes of 2012 and 2013. Laboratories were encouraged to report IFCC traceable results. A parallel study was done to confirm commutability of the samples. Of the 223 participating laboratories, 95% reported IFCC traceable results, ranging from 98% (ASAT) to 87% (amylase). Users of Roche and Siemens (97%) more frequently reported in IFCC traceable results than users of Abbott (91%), Beckman (90%), and Olympus (87%). The success of harmonisation, expressed as the recovery of assigned values and the inter-laboratory CV was: ALAT (recovery 100%; inter-lab CV 4%), ASAT (102%; 4%), LD (98%; 3%), CK (101%; 5%), GGT (98%; 4%), AP (96%; 6%), amylase (99%; 4%). There were no significant differences between the manufacturers. Commutability was demonstrated in the parallel study. Equal results in the same sample in the 2012 and 2013 EQA programmes demonstrated stability of the samples. The EQA-initiated national harmonisation of seven enzymes, using stable, commutable human serum samples, spiked with human recombinant enzymes, and targeted with the IFCC Reference Measurement Procedures, was successful in terms of implementation of IFCC traceable results (95%), recovery of the target (99%), and inter-laboratory CV (4%).

  5. Statistical Analysis for Collision-free Boson Sampling.

    PubMed

    Huang, He-Liang; Zhong, Han-Sen; Li, Tan; Li, Feng-Guang; Fu, Xiang-Qun; Zhang, Shuo; Wang, Xiang; Bao, Wan-Su

    2017-11-10

    Boson sampling is strongly believed to be intractable for classical computers but solvable with photons in linear optics, which raises widespread concern as a rapid way to demonstrate the quantum supremacy. However, due to its solution is mathematically unverifiable, how to certify the experimental results becomes a major difficulty in the boson sampling experiment. Here, we develop a statistical analysis scheme to experimentally certify the collision-free boson sampling. Numerical simulations are performed to show the feasibility and practicability of our scheme, and the effects of realistic experimental conditions are also considered, demonstrating that our proposed scheme is experimentally friendly. Moreover, our broad approach is expected to be generally applied to investigate multi-particle coherent dynamics beyond the boson sampling.

  6. INNOVATIVE TECHNOLOGY EVALUATION REPORT ...

    EPA Pesticide Factsheets

    The Split Core Sampler for Submerged Sediments (Split Core Sampler) designed and fabricated by Arts Manufacturing & Supply, Inc., was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation Program in April and May 1999 at sites in EPA Regions 1 and 5, respectively. In addition to assessing ease of sampler operation, key objectives of the demonstration included evaluating the samplers ability to (1) consistently collect a given volume of sediment, (2) consistently collect sediment in a given depth interval, (3) collect samples with consistent characteristics from a homogenous layer of sediment, and (4) collect samples under a variety of site conditions. This report describes the demonstration results for the Split Core Sampler and two conventional samplers (the Hand Corer and Vibrocorer) used as reference samplers. During the demonstration, the Split Core Sampler performed as well as or better than the reference samplers. Based on visual observations, both the Split Core Sampler and reference samplers collected partially compressed samples of consolidated and unconsolidated sediments from the sediment surface downward; sample representativeness may be questionable because of core shortening and core compression. Sediment stratification was preserved for both consolidated and unconsolidated sediment samples collected by the Split Core Sampler and reference samplers. No sampler was able to collect samples

  7. INNOVATIVE TECHNOLOGY EVALUATION REPORT ...

    EPA Pesticide Factsheets

    The Russian Peat Borer designed and fabricated by Aquatic Research Instruments was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation Program in April and May 1999 at sites in EPA Regions 1 and 5, respectively. In addition to assessing ease of sampler operation, key objectives of the demonstration included evaluating the sampler?s ability to (1) consistently collect a given volume of sediment, (2) consistently collect sediment in a given depth interval, (3) collect samples with consistent characteristics from a homogenous layer of sediment, and (4) collect samples under a variety of site conditions. This report describes the demonstration results for the Russian Peat Borer and two conventional samplers (the Hand Corer and Vibrocorer) used as reference samplers. During the demonstration, the Russian Peat Borer was the only sampler that collected samples in the deep depth interval (4 to 11 feet below sediment surface). It collected representative and relatively uncompressed core samples of consolidated sediment in discrete depth intervals. The reference samplers collected relatively compressed samples of both consolidated and unconsolidated sediments from the sediment surface downward; sample representativeness may be questionable because of core shortening and core compression. Sediment stratification was preserved only for consolidated sediment samples collected by the Russian Peat Borer but for bo

  8. Development of a biaxial compression device for biological samples: preliminary experimental results for a closed cell foam.

    PubMed

    Little, J P; Tevelen, G; Adam, C J; Evans, J H; Pearcy, M J

    2009-07-01

    Biological tissues are subjected to complex loading states in vivo and in order to define constitutive equations that effectively simulate their mechanical behaviour under these loads, it is necessary to obtain data on the tissue's response to multiaxial loading. Single axis and shear testing of biological tissues is often carried out, but biaxial testing is less common. We sought to design and commission a biaxial compression testing device, capable of obtaining repeatable data for biological samples. The apparatus comprised a sealed stainless steel pressure vessel specifically designed such that a state of hydrostatic compression could be created on the test specimen while simultaneously unloading the sample along one axis with an equilibrating tensile pressure. Thus a state of equibiaxial compression was created perpendicular to the long axis of a rectangular sample. For the purpose of calibration and commissioning of the vessel, rectangular samples of closed cell ethylene vinyl acetate (EVA) foam were tested. Each sample was subjected to repeated loading, and nine separate biaxial experiments were carried out to a maximum pressure of 204 kPa (30 psi), with a relaxation time of two hours between them. Calibration testing demonstrated the force applied to the samples had a maximum error of 0.026 N (0.423% of maximum applied force). Under repeated loading, the foam sample demonstrated lower stiffness during the first load cycle. Following this cycle, an increased stiffness, repeatable response was observed with successive loading. While the experimental protocol was developed for EVA foam, preliminary results on this material suggest that this device may be capable of providing test data for biological tissue samples. The load response of the foam was characteristic of closed cell foams, with consolidation during the early loading cycles, then a repeatable load-displacement response upon repeated loading. The repeatability of the test results demonstrated the ability of the test device to provide reproducible test data and the low experimental error in the force demonstrated the reliability of the test data.

  9. Application of picosecond laser-induced breakdown spectroscopy to quantitative analysis of boron in meatballs and other biological samples.

    PubMed

    Hedwig, Rinda; Lahna, Kurnia; Lie, Zener Sukra; Pardede, Marincan; Kurniawan, Koo Hendrik; Tjia, May On; Kagawa, Kiichiro

    2016-11-10

    This report presents the results of laser-induced breakdown spectroscopy (LIBS) study on biological and food samples of high water content using a picosecond (ps) laser at low output energy of 10 mJ and low-pressure helium ambient gas at 2 kPa. Evidence of excellent emission spectra of various analyte elements with very low background is demonstrated for a variety of samples without the need of sample pretreatment. Specifically, limits of detection in the range of sub-ppm are obtained for hazardous Pb and B impurities in carrots and meatballs. This study also shows the inferior performance of LIBS using a nanosecond laser and atmospheric ambient air for a soft sample of high water content and thereby explains its less successful applications in previous attempts. The present result has instead demonstrated the feasibility and favorable results of employing LIBS with a ps laser and low-pressure helium ambient gas as a less costly and more practical alternative to inductively coupled plasma for regular high sensitive inspection of harmful food preservatives and environmental pollutants.

  10. Demonstration and Verification of a Turbine Power Generation System Utilizing Renewable Fuel: Landfill Gas

    DTIC Science & Technology

    2013-09-01

    33 4.7 SAMPLING RESULTS ...34 5.0 PERFORMANCE RESULTS ...PERFORMANCE RESULTS DISCUSSION ............................................................................ 39 5.2.1 Energy: Verify Power Production

  11. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Elvatech, Ltd. ElvaX (ElvaX) x-ray fluorescence (XRF) analyzer distributed in the United States by Xcalibur XRF Services (Xcalibur), was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the ElvaX analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the ElvaX analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as s

  12. Graphene Nanoplatelet Reinforced Tantalum Carbide

    DTIC Science & Technology

    2015-08-27

    testing showed an increase in thermal conductivity in GNP reinforced composites resulting in a reduction of peak sample surface temperature. This study...showed an increase in thermal conductivity in GNP reinforced composites resulting in a reduction of peak sample surface temperature. This study resulted...Wetting angle measurements are conducted to demonstrate the effectiveness of the PLC coating . Mechanical properties of the GrF-PLC hybrid are

  13. TECHNOLOGIES FOR MONITORING AND MEASUREMENT ...

    EPA Pesticide Factsheets

    A demonstration of technologies for determining the presence of dioxin and dioxin-like compounds in soil and sediment was conducted under EPA's Superfund Innovative Technology Evaluation Program in Saginaw, Michigan in April 2004. This report describes the performance evaluation of the Abraxis LLC Coplanar PCB Enzyme-Linked Immunosorbent Assay (ELISA) kit. The kit is an immunoassay technique that reports the total toxicity equivalents (TEQ) of polychlorinated biphenyls (PCBs). The technology results were compared to high resolution mass spectrometry TEQ results generated using EPA Method 1668A.Abraxis generally reported data that were higher than the reference laboratory TEQPCB values, with the exception of ultra-high level PCB samples [> 10,000 picogram/gram (pg/g) TEQ] where Abraxis reported values lower than the reference method. The technologys estimated MDL was 6 to 31 pg/g TEQPCB. Results from this demonstration suggest that the Abraxis kit could be an effective screening tool for screening sample concentrations above and below 50 pg/g TEQPCB, particularly considering that the cost ($22,668 vs. $184,449) and the time to analyze the 209 demonstration samples were significantly less than those of the reference laboratory. The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented performance and cost data obtained from field demonstrations.

  14. Laboratory evaluation of sample collection methods (organs vs swabs) for Tasmanian salmon reovirus detection in farmed Atlantic salmon, Salmo salar L.

    PubMed

    Zainathan, S C; Carson, J; Crane, M St J; Nowak, B F

    2013-04-01

    The use of swabs relative to organs as a sample collection method for the detection of Tasmanian salmon reovirus (TSRV) in farmed Tasmanian Atlantic salmon, Salmo salar L., was evaluated by RT-qPCR. Evaluation of individual and pooled sample collection (organs vs swabs) was carried out to determine the sensitivity of the collection methods and the effect of pooling of samples for the detection of TSRV. Detection of TSRV in individual samples was as sensitive when organs were sampled compared to swabs, and in pooled samples, organs demonstrated a sensitivity of one 10-fold dilution higher than sampling of pooled swabs. Storage of swabs at 4 °C for t = 24 h demonstrated results similar to those at t = 0. Advantages of using swabs as a preferred sample collection method for the detection of TSRV compared to organ samples are evident from these experimental trials. © 2012 Blackwell Publishing Ltd.

  15. Superoxygenated Water as an Experimental Sample for NMR Relaxometry

    ERIC Educational Resources Information Center

    Nestle, Nikolaus; Dakkouri, Marwan; Rauscher, Hubert

    2004-01-01

    The increase in NMR relaxation rates as a result of dissolved paramagnetic species on the sample of superoxygenated drinking water is demonstrated. It is concluded that oxygen content in NMR samples is an important issue and can give rise to various problems in the interpretation of both spectroscopic and NMR imaging or relaxation experiments.

  16. Local Feature Selection for Data Classification.

    PubMed

    Armanfard, Narges; Reilly, James P; Komeili, Majid

    2016-06-01

    Typical feature selection methods choose an optimal global feature subset that is applied over all regions of the sample space. In contrast, in this paper we propose a novel localized feature selection (LFS) approach whereby each region of the sample space is associated with its own distinct optimized feature set, which may vary both in membership and size across the sample space. This allows the feature set to optimally adapt to local variations in the sample space. An associated method for measuring the similarities of a query datum to each of the respective classes is also proposed. The proposed method makes no assumptions about the underlying structure of the samples; hence the method is insensitive to the distribution of the data over the sample space. The method is efficiently formulated as a linear programming optimization problem. Furthermore, we demonstrate the method is robust against the over-fitting problem. Experimental results on eleven synthetic and real-world data sets demonstrate the viability of the formulation and the effectiveness of the proposed algorithm. In addition we show several examples where localized feature selection produces better results than a global feature selection method.

  17. Can Selforganizing Maps Accurately Predict Photometric Redshifts?

    NASA Technical Reports Server (NTRS)

    Way, Michael J.; Klose, Christian

    2012-01-01

    We present an unsupervised machine-learning approach that can be employed for estimating photometric redshifts. The proposed method is based on a vector quantization called the self-organizing-map (SOM) approach. A variety of photometrically derived input values were utilized from the Sloan Digital Sky Survey's main galaxy sample, luminous red galaxy, and quasar samples, along with the PHAT0 data set from the Photo-z Accuracy Testing project. Regression results obtained with this new approach were evaluated in terms of root-mean-square error (RMSE) to estimate the accuracy of the photometric redshift estimates. The results demonstrate competitive RMSE and outlier percentages when compared with several other popular approaches, such as artificial neural networks and Gaussian process regression. SOM RMSE results (using delta(z) = z(sub phot) - z(sub spec)) are 0.023 for the main galaxy sample, 0.027 for the luminous red galaxy sample, 0.418 for quasars, and 0.022 for PHAT0 synthetic data. The results demonstrate that there are nonunique solutions for estimating SOM RMSEs. Further research is needed in order to find more robust estimation techniques using SOMs, but the results herein are a positive indication of their capabilities when compared with other well-known methods

  18. An experimental verification of laser-velocimeter sampling bias and its correction

    NASA Technical Reports Server (NTRS)

    Johnson, D. A.; Modarress, D.; Owen, F. K.

    1982-01-01

    The existence of 'sampling bias' in individual-realization laser velocimeter measurements is experimentally verified and shown to be independent of sample rate. The experiments were performed in a simple two-stream mixing shear flow with the standard for comparison being laser-velocimeter results obtained under continuous-wave conditions. It is also demonstrated that the errors resulting from sampling bias can be removed by a proper interpretation of the sampling statistics. In addition, data obtained in a shock-induced separated flow and in the near-wake of airfoils are presented, both bias-corrected and uncorrected, to illustrate the effects of sampling bias in the extreme.

  19. Growth and characterization of AlInAsSb layers lattice-matched to GaSb

    NASA Astrophysics Data System (ADS)

    Tournet, J.; Rouillard, Y.; Tournié, E.

    2017-11-01

    We report on the growth by solid-source MBE of random-alloy AlxIn1-xAsySb1-y layers lattice-matched to (0 0 1)-GaSb substrates, with xAl ∈ [0.25; 0.75]. The samples quality and morphology were characterized by X-ray diffraction, Nomarski microscopy and atomic force microscopy. Layers grown at 400 °C demonstrated smooth surfaces and no sign of phase decomposition. Samples with xAl ≤ 0.60 demonstrated photoluminescence (PL) at 300 K whereas samples with higher Al content only demonstrated PL at low temperature. Samples grown at 430 °C, in contrast, exhibited PL at low temperature only, whatever their composition. Inferred bandgap energies corroborate the estimation of a non-null quaternary bowing parameter made by Donati, Kaspi and Malloy in Journal of Applied Physics 94 (2003) 5814. Upon annealing, the PL peak energies increased, getting even closer to the theoretical values. These results are in agreement with recently published results on digital AlInAsSb alloys. Our work, which reports the first evidence for PL emission from random-alloy AlInAsSb layers lattice-matched to GaSb, opens the way to their use in optoelectronic devices.

  20. Demonstration and Optimization of BNFL's Pulsed Jet Mixing and RFD Sampling Systems Using NCAW Simulant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    JR Bontha; GR Golcar; N Hannigan

    2000-08-29

    The BNFL Inc. flowsheet for the pretreatment and vitrification of the Hanford High Level Tank waste includes the use of several hundred Reverse Flow Diverters (RFDs) for sampling and transferring the radioactive slurries and Pulsed Jet mixers to homogenize or suspend the tank contents. The Pulsed Jet mixing and the RFD sampling devices represent very simple and efficient methods to mix and sample slurries, respectively, using compressed air to achieve the desired operation. The equipment has no moving parts, which makes them very suitable for mixing and sampling highly radioactive wastes. However, the effectiveness of the mixing and sampling systemsmore » are yet to be demonstrated when dealing with Hanford slurries, which exhibit a wide range of physical and theological properties. This report describes the results of the testing of BNFL's Pulsed Jet mixing and RFD sampling systems in a 13-ft ID and 15-ft height dish-bottomed tank at Battelle's 336 building high-bay facility using AZ-101/102 simulants containing up to 36-wt% insoluble solids. The specific objectives of the work were to: Demonstrate the effectiveness of the Pulsed Jet mixing system to thoroughly homogenize Hanford-type slurries over a range of solids loading; Minimize/optimize air usage by changing sequencing of the Pulsed Jet mixers or by altering cycle times; and Demonstrate that the RFD sampler can obtain representative samples of the slurry up to the maximum RPP-WTP baseline concentration of 25-wt%.« less

  1. Limitations of an ocular surface inflammatory biomarker in impression cytology specimens.

    PubMed

    Yafawi, Rolla; Ko, Mira; Sace, Frederick P; John-Baptiste, Annette

    2013-03-01

    A number of ocular conditions, such as dry eye, are associated with inflammation on the surface of the eye leading to irritation and ocular pain. Many drugs such as chemotherapeutics, beta blockers, angiotensin-converting enzymes and so forth also cause dry eye but currently there are no validated ocular surface biomarkers available. We evaluated sample stability, assay sensitivity, reproducibility and overall performance of impression cytology (IC) utilizing the cellular surface biomarker human leukocyte antigen DR-1 (HLA-DR) as an ocular surface inflammatory biomarker by flow cytometry in a fit-for-purpose validation study. Additionally, subjects classified as normal or having various degrees of dry eye were evaluated to determine if HLA-DR could demonstrate a clear separation between normal and dry eye samples. The assay demonstrated high dynamic range detecting a broad range of fluorescent intensities in healthy donors. Additionally, inter, intra and stability assay results demonstrated strong concordance and low variability. Overall CV% for both assays were less than 25% for all measured parameters. However, high variability was observed for donor samples assayed beyond day 10 post IC sample collection (4.2-110.8 CV%). HLA-DR expression demonstrated a progressive increase in patients with mild to severe levels of dry eye disease providing sufficient evidence it is sensitive enough to monitor inflammatory effects of dry eye when coupled with additional biomarkers and/or methodologies such as cytokine analysis or ICAM-1. This biomarker can be used to monitor ocular surface disorders in patients and to evaluate potential treatment options during drug development. Although our results demonstrate this methodology is reproducible for routine evaluation, limitations around sample integrity exist. The ocular cell surface inflammatory biomarker, HLA-DR coupled with impression cytology is a simple non-invasive robust, specific and reproducible assay that can be utilized to measure inflammatory infiltrates on the surface of the eye in IC samples less than 10-days old.

  2. Technology Demonstration of the Zero Emissions Chromium Electroplating System

    DTIC Science & Technology

    2008-02-01

    Phase I trivalent chromium results ................................................................... 23 18 Phase II total chromium in PRD fluid results...0 xa B D F H J L Sam pies Figure 16. Phase II iron results. ERDC/CERL TR-05-35, Vol. 1 23 Trivalent Chromium Phase I Analysis for Phase I was...with the samples. Each sample was analyzed twice, and an average was computed. Figure 17 shows the results. ANAD has specified that Trivalent Chromium

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yashchuk, Valeriy V; Conley, Raymond; Anderson, Erik H.

    We discuss the results of SEM and TEM measurements with the BPRML test samples fabricated from a BPRML (WSi2/Si with fundamental layer thickness of 3 nm) with a Dual Beam FIB (focused ion beam)/SEM technique. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize x-raymore » microscopes. Corresponding work with x-ray microscopes is in progress.« less

  4. Heterophile antibody interference in qualitative urine/serum hCG devices: Case report.

    PubMed

    Patel, Khushbu K; Gronowski, Ann M

    2016-06-01

    This case report investigates the origin of a false positive result on a serum qualitative human chorionic gonadotropin (hCG) device. A 46-year-old woman diagnosed with chronic myeloid leukemia presented with nausea and vomiting. A qualitative serum hCG test was interpreted as positive; however, a quantitative serum hCG test was negative (<5IU/L). To further investigate this discrepancy, the sample was pretreated with heterophilic blocking reagent (HBR). Additionally, the sample was tested on other qualitative hCG devices composed of antibodies from different animal sources. Blocking reagent from an automated quantitative immunoassay was also tested for its ability to inhibit the heterophile antibody interference. The qualitative test result was negative after pretreatment with heterophilic blocking reagent. Other devices composed of antibodies from different animal sources also demonstrated mixed results with the patient's sample. Blocking reagent obtained from the automated quantitative assay inhibited the heterophile antibody interference in the patient's sample. This case demonstrates that positive serum point-of-care hCG results should be interpreted with caution and confirmed with a quantitative serum hCG immunoassay when clinical suspicion is raised. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  5. Low acetaldehyde collection efficiencies for 24-hour sampling with 2,4-dinitrophenylhydrazine (DNPH)-coated solid sorbents.

    PubMed

    Herrington, Jason S; Fan, Zhi-Hua Tina; Lioy, Paul J; Zhang, Junfeng Jim

    2007-01-15

    Airborne aldehyde and ketone (carbonyl) sampling methodologies based on derivatization with 2,4-dinitrophenylhydrazine (DNPH)-coated solid sorbents could unequivocally be considered the "gold" standard. Originally developed in the late 1970s, these methods have been extensively evaluated and developed up to the present day. However, these methods have been inadequately evaluated for the long-term (i.e., 24 h or greater) sampling collection efficiency (CE) of carbonyls other than formaldehyde. The current body of literature fails to demonstrate that DNPH-coated solid sorbent sampling methods have acceptable CEs for the long-term sampling of carbonyls other than formaldehyde. Despite this, such methods are widely used to report the concentrations of multiple carbonyls from long-term sampling, assuming approximately 100% CEs. Laboratory experiments were conducted in this study to evaluate the long-term formaldehyde and acetaldehyde sampling CEs for several commonly used DNPH-coated solid sorbents. Results from sampling known concentrations of formaldehyde and acetaldehyde generated in a dynamic atmosphere generation system demonstrate that the 24-hour formaldehyde sampling CEs ranged from 83 to 133%, confirming the findings made in previous studies. However, the 24-hour acetaldehyde sampling CEs ranged from 1 to 62%. Attempts to increase the acetaldehyde CEs by adding acid to the samples post sampling were unsuccessful. These results indicate that assuming approximately 100% CEs for 24-hour acetaldehyde sampling, as commonly done with DNPH-coated solid sorbent methods, would substantially under estimate acetaldehyde concentrations.

  6. Transition to motherhood and the self: measurement, stability, and change.

    PubMed

    Ruble, D N; Brooks-Gunn, J; Fleming, A S; Fitzmaurice, G; Stangor, C; Deutsch, F

    1990-03-01

    Different ways of conceptualizing and measuring change in attitudes during transition to motherhood are examined. A series of analyses was performed on data from a cross-sectional sample (N = 667) and a smaller longitudinal sample (n = 48) to demonstrate sound psychometric properties for 2 new scales and to show construct comparability across different phases of childbearing. For Childbearing Attitudes Questionnaire, results demonstrated equality of covariance for 16 scales and comparability of structure and meaning of 4 higher order factors--identification with motherhood, social orientation, self-confidence, and negative aspects of giving birth. For Mothering Self-Definition Questionnaire, results demonstrated equality of covariance of 5 scales and comparability of structure and meaning of a single higher order factor, interpreted as reflecting positive feelings about one's mothering characteristics. Analyses of correlations and mean differences identified areas of change and stability.

  7. Rasch fit statistics and sample size considerations for polytomous data

    PubMed Central

    Smith, Adam B; Rush, Robert; Fallowfield, Lesley J; Velikova, Galina; Sharpe, Michael

    2008-01-01

    Background Previous research on educational data has demonstrated that Rasch fit statistics (mean squares and t-statistics) are highly susceptible to sample size variation for dichotomously scored rating data, although little is known about this relationship for polytomous data. These statistics help inform researchers about how well items fit to a unidimensional latent trait, and are an important adjunct to modern psychometrics. Given the increasing use of Rasch models in health research the purpose of this study was therefore to explore the relationship between fit statistics and sample size for polytomous data. Methods Data were collated from a heterogeneous sample of cancer patients (n = 4072) who had completed both the Patient Health Questionnaire – 9 and the Hospital Anxiety and Depression Scale. Ten samples were drawn with replacement for each of eight sample sizes (n = 25 to n = 3200). The Rating and Partial Credit Models were applied and the mean square and t-fit statistics (infit/outfit) derived for each model. Results The results demonstrated that t-statistics were highly sensitive to sample size, whereas mean square statistics remained relatively stable for polytomous data. Conclusion It was concluded that mean square statistics were relatively independent of sample size for polytomous data and that misfit to the model could be identified using published recommended ranges. PMID:18510722

  8. Personal exposure to aerosolized red tide toxins (brevetoxins).

    PubMed

    Cheng, Yung Sung; Zhou, Yue; Naar, Jerome; Irvin, C Mitch; Su, Wei-Chung; Fleming, Lora E; Kirkpatrick, Barbara; Pierce, Richard H; Backer, Lorraine C; Baden, Daniel G

    2010-06-01

    Florida red tides occur annually in the Gulf of Mexico from blooms of the marine dinoflagellate, Karenia brevis, which produces highly potent natural polyether toxins, brevetoxins. Several epidemiologic studies have demonstrated that human exposure to red tide aerosol could result in increased respiratory symptoms. Environmental monitoring of aerosolized brevetoxins was performed using a high-volume sampler taken hourly at fixed locations on Siesta Beach, Florida. Personal exposure was monitored using personal air samplers and taking nasal swab samples from the subjects who were instructed to spend 1 hr on Sarasota Beach during two sampling periods of an active Florida red tide event in March 2005, and in May 2008 when there was no red tide. Results showed that the aerosolized brevetoxins from the personal sampler were in modest agreement with the environmental concentration taken from a high-volume sampler. Analysis of nasal swab samples for brevetoxins demonstrated 68% positive samples in the March 2005 sampling period when air concentrations of brevetoxins were between 50 to 120 ng/m(3) measured with the high-volume sampler. No swab samples showed detectable levels of brevetoxins in the May 2008 study, when all personal samples were below the limit of detection. However, there were no statistical correlations between the amounts of brevetoxins detected in the swab samples with either the environmental or personal concentration. Results showed that the personal sample might provide an estimate of individual exposure level. Nasal swab samples showed that brevetoxins indeed were inhaled and deposited in the nasal passage during the March 2005 red tide event.

  9. On the abiotic formation of amino acids. I - HCN as a precursor of amino acids detected in extracts of lunar samples. II - Formation of HCN and amino acids from simulated mixtures of gases released from lunar samples

    NASA Technical Reports Server (NTRS)

    Yuasa, S.; Flory, D.; Basile, B.; Oro, J.

    1984-01-01

    Two studies on the abiotic formation of amino acids are presented. The first study demonstrates the role of hydrogen cyanide as a precursor of amino acids detected in extracts of lunar samples. The formation of several amino acids, including glycine, alanine, aspartic acid, and glutamic acid, under conditions similar to those used for the analysis of lunar samples is demonstrated. The second study investigates the formation of hydrogen cyanide as well as amino acids from lunar-sample gas mixtures under electrical discharge conditions. These results extend the possibility of synthesis of amino acids to planetary bodies with primordial atmospheres less reducing than a mixture of methane, ammonia, hydrogen and water.

  10. Accelerating Sequences in the Presence of Metal by Exploiting the Spatial Distribution of Off-Resonance

    PubMed Central

    Smith, Matthew R.; Artz, Nathan S.; Koch, Kevin M.; Samsonov, Alexey; Reeder, Scott B.

    2014-01-01

    Purpose To demonstrate feasibility of exploiting the spatial distribution of off-resonance surrounding metallic implants for accelerating multispectral imaging techniques. Theory Multispectral imaging (MSI) techniques perform time-consuming independent 3D acquisitions with varying RF frequency offsets to address the extreme off-resonance from metallic implants. Each off-resonance bin provides a unique spatial sensitivity that is analogous to the sensitivity of a receiver coil, and therefore provides a unique opportunity for acceleration. Methods Fully sampled MSI was performed to demonstrate retrospective acceleration. A uniform sampling pattern across off-resonance bins was compared to several adaptive sampling strategies using a total hip replacement phantom. Monte Carlo simulations were performed to compare noise propagation of two of these strategies. With a total knee replacement phantom, positive and negative off-resonance bins were strategically sampled with respect to the B0 field to minimize aliasing. Reconstructions were performed with a parallel imaging framework to demonstrate retrospective acceleration. Results An adaptive sampling scheme dramatically improved reconstruction quality, which was supported by the noise propagation analysis. Independent acceleration of negative and positive off-resonance bins demonstrated reduced overlapping of aliased signal to improve the reconstruction. Conclusion This work presents the feasibility of acceleration in the presence of metal by exploiting the spatial sensitivities of off-resonance bins. PMID:24431210

  11. Assessing generative braille responding following training in a matching-to-sample format.

    PubMed

    Putnam, Brittany C; Tiger, Jeffrey H

    2016-12-01

    We evaluated the effects of teaching sighted college students to select printed text letters given a braille sample stimulus in a matching-to-sample (MTS) format on the emergence of untrained (a) construction of print characters given braille samples, (b) construction of braille characters given print samples, (c) transcription of print characters given braille sample sentences, and (d) vocal reading given braille sample passages. The results demonstrated the generative development of these repertoires given MTS instruction. © 2016 Society for the Experimental Analysis of Behavior.

  12. Demonstration of femtosecond laser ablation inductively coupled plasma mass spectrometry for uranium isotopic measurements in U-10Mo nuclear fuel foils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Havrilla, George Joseph; Gonzalez, Jhanis

    2015-06-10

    The use of femtosecond laser ablation inductively coupled plasma mass spectrometry was used to demonstrate the feasibility of measuring the isotopic ratio of uranium directly in U-10Mo fuel foils. The measurements were done on both the flat surface and cross sections of bare and Zr clad U-10Mo fuel foil samples. The results for the depleted uranium content measurements were less than 10% of the accepted U235/238 ratio of 0.0020. Sampling was demonstrated for line scans and elemental mapping over large areas. In addition to the U isotopic ratio measurement, the Zr thickness could be measured as well as trace elementalmore » composition if required. A number of interesting features were observed during the feasibility measurements which could provide the basis for further investigation using this methodology. The results demonstrate the feasibility of using fs-LA-ICP-MS for measuring the U isotopic ratio in U-10Mo fuel foils.« less

  13. INNOVATIVE TECHNOLOGY VERIFICATION REPORT " ...

    EPA Pesticide Factsheets

    The EnSys Petro Test System developed by Strategic Diagnostics Inc. (SDI), was demonstrated under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in June 2000 at the Navy Base Ventura County site in Port Hueneme, California. The purpose of the demonstration was to collect reliable performance and cost data for the EnSys Petro Test System and six other field measurement devices for total petroleum hydrocarbons (TPH) in soil. In addition to assessing ease of device operation, the key objectives of the demonstration included determining the (1) method detection limit, (2) accuracy and precision, (3) effects of interferents and soil moisture content on TPH measurement, (4) sample throughput, and (5) TPH measurement costs for each device. The demonstration involved analysis of both performance evaluation samples and environmental samples collected in four areas contaminated with gasoline, diesel, or other petroleum products. The performance and cost results for a given field measurement device were compared to those for an off-site laboratory reference method,

  14. INNOVATIVE TECHNOLOGY VERIFICATION REPORT " ...

    EPA Pesticide Factsheets

    The Synchronous Scanning Luminoscope (Luminoscope) developed by the Oak Ridge National Laboratory in collaboration with Environmental Systems Corporation (ESC) was demonstrated under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in June 2000 at the Navy Base Ventura County site in Port Hueneme, California. The purpose of the demonstration was to collect reliable performance and cost data for the Luminoscope and six other field measurement devices for total petroleum hydrocarbons (TPH) in soil. In addition to assessing ease of device operation, the key objectives of the demonstration included determining the (1) method detection limit, (2) accuracy and precision, (3) effects of interferents and soil moisture content on TPH measurement, (4) sample throughput, and (5) TPH measurement costs for each device. The demonstration involved analysis of both performance evaluation samples and environmental samples collected in five areas contaminated with gasoline, diesel, lubricating oil, or other petroleum products. The performance and cost results for a given field measurement device were compared to those for an off-site laboratory reference method,

  15. European Multicenter Study on Analytical Performance of DxN Veris System HCV Assay.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Gismondo, Maria Rita; Hofmann, Jörg; Izopet, Jacques; Kühn, Sebastian; Lombardi, Alessandra; Marcos, Maria Angeles; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel W

    2017-04-01

    The analytical performance of the Veris HCV Assay for use on the new and fully automated Beckman Coulter DxN Veris Molecular Diagnostics System (DxN Veris System) was evaluated at 10 European virology laboratories. Precision, analytical sensitivity, specificity, and performance with negative samples, linearity, and performance with hepatitis C virus (HCV) genotypes were evaluated. Precision for all sites showed a standard deviation (SD) of 0.22 log 10 IU/ml or lower for each level tested. Analytical sensitivity determined by probit analysis was between 6.2 and 9.0 IU/ml. Specificity on 94 unique patient samples was 100%, and performance with 1,089 negative samples demonstrated 100% not-detected results. Linearity using patient samples was shown from 1.34 to 6.94 log 10 IU/ml. The assay demonstrated linearity upon dilution with all HCV genotypes. The Veris HCV Assay demonstrated an analytical performance comparable to that of currently marketed HCV assays when tested across multiple European sites. Copyright © 2017 American Society for Microbiology.

  16. Zooming in on vibronic structure by lowest-value projection reconstructed 4D coherent spectroscopy

    NASA Astrophysics Data System (ADS)

    Harel, Elad

    2018-05-01

    A fundamental goal of chemical physics is an understanding of microscopic interactions in liquids at and away from equilibrium. In principle, this microscopic information is accessible by high-order and high-dimensionality nonlinear optical measurements. Unfortunately, the time required to execute such experiments increases exponentially with the dimensionality, while the signal decreases exponentially with the order of the nonlinearity. Recently, we demonstrated a non-uniform acquisition method based on radial sampling of the time-domain signal [W. O. Hutson et al., J. Phys. Chem. Lett. 9, 1034 (2018)]. The four-dimensional spectrum was then reconstructed by filtered back-projection using an inverse Radon transform. Here, we demonstrate an alternative reconstruction method based on the statistical analysis of different back-projected spectra which results in a dramatic increase in sensitivity and at least a 100-fold increase in dynamic range compared to conventional uniform sampling and Fourier reconstruction. These results demonstrate that alternative sampling and reconstruction methods enable applications of increasingly high-order and high-dimensionality methods toward deeper insights into the vibronic structure of liquids.

  17. Development of Gold Standard Ion-Selective Electrode-Based Methods for Fluoride Analysis

    PubMed Central

    Martínez-Mier, E.A.; Cury, J.A.; Heilman, J.R.; Katz, B.P.; Levy, S.M.; Li, Y.; Maguire, A.; Margineda, J.; O’Mullane, D.; Phantumvanit, P.; Soto-Rojas, A.E.; Stookey, G.K.; Villa, A.; Wefel, J.S.; Whelton, H.; Whitford, G.M.; Zero, D.T.; Zhang, W.; Zohouri, V.

    2011-01-01

    Background/Aims: Currently available techniques for fluoride analysis are not standardized. Therefore, this study was designed to develop standardized methods for analyzing fluoride in biological and nonbiological samples used for dental research. Methods A group of nine laboratories analyzed a set of standardized samples for fluoride concentration using their own methods. The group then reviewed existing analytical techniques for fluoride analysis, identified inconsistencies in the use of these techniques and conducted testing to resolve differences. Based on the results of the testing undertaken to define the best approaches for the analysis, the group developed recommendations for direct and microdiffusion methods using the fluoride ion-selective electrode. Results Initial results demonstrated that there was no consensus regarding the choice of analytical techniques for different types of samples. Although for several types of samples, the results of the fluoride analyses were similar among some laboratories, greater differences were observed for saliva, food and beverage samples. In spite of these initial differences, precise and true values of fluoride concentration, as well as smaller differences between laboratories, were obtained once the standardized methodologies were used. Intraclass correlation coefficients ranged from 0.90 to 0.93, for the analysis of a certified reference material, using the standardized methodologies. Conclusion The results of this study demonstrate that the development and use of standardized protocols for F analysis significantly decreased differences among laboratories and resulted in more precise and true values. PMID:21160184

  18. Noncontact discrimination of animal and human blood with vacuum blood vessel and factors affect the discrimination

    NASA Astrophysics Data System (ADS)

    Zhang, Linna; Zhang, Shengzhao; Sun, Meixiu; Li, Hongxiao; Li, Yingxin; Fu, Zhigang; Guan, Yang; Li, Gang; Lin, Ling

    2017-03-01

    Discrimination of human and nonhuman blood is crucial for import-export ports and inspection and quarantine departments. Current methods are usually destructive, complicated and time-consuming. We had previously demonstrated that visible diffuse reflectance spectroscopy combining PLS-DA method can successfully realize human blood discrimination. In that research, the spectra were measured with the fiber probe under the surface of blood samples. However, open sampling may pollute the blood samples. Virulence factors in blood samples can also endanger inspectors. In this paper, we explored the classification effect with the blood samples measured in the original containers-vacuum blood vessel. Furthermore, we studied the impact of different conditions of blood samples, such as coagulation and hemolysis, on the prediction ability of the discrimination model. The calibration model built with blood samples in different conditions displayed a satisfactory prediction result. This research demonstrated that visible and near-infrared diffuse reflectance spectroscopy method was potential for noncontact discrimination of human blood.

  19. High-throughput automated microfluidic sample preparation for accurate microbial genomics

    PubMed Central

    Kim, Soohong; De Jonghe, Joachim; Kulesa, Anthony B.; Feldman, David; Vatanen, Tommi; Bhattacharyya, Roby P.; Berdy, Brittany; Gomez, James; Nolan, Jill; Epstein, Slava; Blainey, Paul C.

    2017-01-01

    Low-cost shotgun DNA sequencing is transforming the microbial sciences. Sequencing instruments are so effective that sample preparation is now the key limiting factor. Here, we introduce a microfluidic sample preparation platform that integrates the key steps in cells to sequence library sample preparation for up to 96 samples and reduces DNA input requirements 100-fold while maintaining or improving data quality. The general-purpose microarchitecture we demonstrate supports workflows with arbitrary numbers of reaction and clean-up or capture steps. By reducing the sample quantity requirements, we enabled low-input (∼10,000 cells) whole-genome shotgun (WGS) sequencing of Mycobacterium tuberculosis and soil micro-colonies with superior results. We also leveraged the enhanced throughput to sequence ∼400 clinical Pseudomonas aeruginosa libraries and demonstrate excellent single-nucleotide polymorphism detection performance that explained phenotypically observed antibiotic resistance. Fully-integrated lab-on-chip sample preparation overcomes technical barriers to enable broader deployment of genomics across many basic research and translational applications. PMID:28128213

  20. Qualitative evaluation of maternal milk and commercial infant formulas via LIBS.

    PubMed

    Abdel-Salam, Z; Al Sharnoubi, J; Harith, M A

    2013-10-15

    This study focuses on the use of laser-induced breakdown spectroscopy (LIBS) for the evaluation of the nutrients in maternal milk and some commercially available infant formulas. The results of such evaluation are vital for adequate and healthy feeding for babies during lactation period. Laser-induced breakdown spectroscopy offers special advantages in comparison to the other conventional analytical techniques. Specifically, LIBS is a straightforward technique that can be used in situ to provide qualitative analytical information in few minutes for the samples under investigation without preparation processes. The samples studied in the current work were maternal milk samples collected during the first 3 months of lactation (not colostrum milk) and samples from six different types of commercially available infant formulas. The samples' elemental composition has been compared with respect to the relative abundance of the elements of nutrition importance, namely Mg, Ca, Na, and Fe using their spectral emission lines in the relevant LIBS spectra. In addition, CN and C2 molecular emission bands in the same spectra have been studied as indicators of proteins content in the samples. The obtained analytical results demonstrate the higher elemental contents of the maternal milk compared with the commercial formulas samples. Similar results have been obtained as for the proteins content. It has been also shown that calcium and proteins have similar relative concentration trends in the studied samples. This work demonstrates the feasibility of adopting LIBS as a fast, safe, less costly technique evaluating qualitatively the nutrients content of both maternal and commercial milk samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Musgrove, Cameron H.; West, James C.

    Missing samples within synthetic aperture radar data result in image distortions. For coherent data products, such as coherent change detection and interferometric processing, the image distortion can be devastating to these second order products, resulting in missed detections and inaccurate height maps. Earlier approaches to repair the coherent data products focus upon reconstructing the missing data samples. This study demonstrates that reconstruction is not necessary to restore the quality of the coherent data products.

  2. False-positive LSD testing in urine samples from intensive care patients.

    PubMed

    Röhrich, J; Zörntlein, S; Lotz, J; Becker, J; Kern, T; Rittner, C

    1998-09-01

    Unexpected positive results for lysergic acid diethylamide (LSD) were found in urine samples from 12 patients in an intensive care unit in a routine screening using the CEDIA DAU assay. None of these test results could be confirmed by high-performance liquid chromatography analysis, but all samples contained the mucolytic drug ambroxol. Further studies demonstrated that ambroxol exhibits a significant cross-reactivity in the CEDIA DAU LSD assay. Therefore, positive LSD results obtained with the CEDIA DAU assay have to be critically evaluated, particularly during the cold season, when infections of the respiratory tract often result in more frequent use of mucolytic medications.

  3. Psychometric properties of the Penn State Worry Questionnaire for children in a large clinical sample.

    PubMed

    Pestle, Sarah L; Chorpita, Bruce F; Schiffman, Jason

    2008-04-01

    The Penn State Worry Questionnaire for Children (PSWQ-C; Chorpita, Tracey, Brown, Collica, & Barlow, 1997) is a 14-item self-report measure of worry in children and adolescents. Although the PSWQ-C has demonstrated favorable psychometric properties in small clinical and large community samples, this study represents the first psychometric evaluation of the PSWQ-C in a large clinical sample (N = 491). Factor analysis indicated a two-factor structure, in contrast to all previously published findings on the measure. The PSWQ-C demonstrated favorable psychometric properties in this sample, including high internal consistency, high convergent validity with related constructs, and acceptable discriminative validity between diagnostic categories. The performance of the 3 reverse-scored items was closely examined, and results indicated retaining all 14 items.

  4. Exploiting molecular dynamics in Nested Sampling simulations of small peptides

    NASA Astrophysics Data System (ADS)

    Burkoff, Nikolas S.; Baldock, Robert J. N.; Várnai, Csilla; Wild, David L.; Csányi, Gábor

    2016-04-01

    Nested Sampling (NS) is a parameter space sampling algorithm which can be used for sampling the equilibrium thermodynamics of atomistic systems. NS has previously been used to explore the potential energy surface of a coarse-grained protein model and has significantly outperformed parallel tempering when calculating heat capacity curves of Lennard-Jones clusters. The original NS algorithm uses Monte Carlo (MC) moves; however, a variant, Galilean NS, has recently been introduced which allows NS to be incorporated into a molecular dynamics framework, so NS can be used for systems which lack efficient prescribed MC moves. In this work we demonstrate the applicability of Galilean NS to atomistic systems. We present an implementation of Galilean NS using the Amber molecular dynamics package and demonstrate its viability by sampling alanine dipeptide, both in vacuo and implicit solvent. Unlike previous studies of this system, we present the heat capacity curves of alanine dipeptide, whose calculation provides a stringent test for sampling algorithms. We also compare our results with those calculated using replica exchange molecular dynamics (REMD) and find good agreement. We show the computational effort required for accurate heat capacity estimation for small peptides. We also calculate the alanine dipeptide Ramachandran free energy surface for a range of temperatures and use it to compare the results using the latest Amber force field with previous theoretical and experimental results.

  5. Study of the rhizobacterium Azospirillum brasilense Sp245 using Mössbauer spectroscopy with a high velocity resolution: Implication for the analysis of ferritin-like iron cores

    NASA Astrophysics Data System (ADS)

    Alenkina, I. V.; Oshtrakh, M. I.; Tugarova, A. V.; Biró, B.; Semionkin, V. A.; Kamnev, A. A.

    2014-09-01

    The results of a comparative study of two samples of the rhizobacterium Azospirillum brasilense (strain Sp245) prepared in different conditions and of human liver ferritin using Mössbauer spectroscopy with a high velocity resolution demonstrated the presence of ferritin-like iron (i.e. iron similar to that found in ferritin-like proteins) in the bacterium. Mössbauer spectra of these samples were fitted in two ways: as a rough approximation using a one quadrupole doublet fit (the homogeneous iron core model) and using a superposition of quadrupole doublets (the heterogeneous iron core model). Both results demonstrated differences in the Mössbauer parameters for mammalian ferritin and for bacterial ferritin-like iron. Moreover, some differences in the Mössbauer parameters were observed between the two samples of A. brasilense Sp245 related to the differences in their preparation conditions.

  6. The interaction of birth order and parental age on sexual orientation: an examination in two samples.

    PubMed

    Bogaert, Anthony F; Cairney, John

    2004-01-01

    A birth order and sexual orientation relationship has been demonstrated numerous times in men, but a related variable, parental age (i.e. age of parents when the participant was born), has been less studied and has demonstrated contradictory results. In this research, the relations among birth order, parental age and sexual orientation were examined in a national probability sample of the US (Kessler, 1994; Kessler et al., 1994) and in a Canadian sample of homosexual and heterosexual men closely matched on demographic characteristics (Blanchard & Bogaert, 1996a). In both studies, an interaction between birth order and parental age was observed in men, such that there was positive association between number of older siblings and the likelihood of homosexuality, but this association weakened with increasing parental age. No significant effects were observed for women. The results are discussed in relation to recent theories of the birth order/sexual orientation relationship.

  7. Longitudinal On-Column Thermal Modulation for Comprehensive Two-Dimensional Liquid Chromatography.

    PubMed

    Creese, Mari E; Creese, Mathew J; Foley, Joe P; Cortes, Hernan J; Hilder, Emily F; Shellie, Robert A; Breadmore, Michael C

    2017-01-17

    Longitudinal on-column thermal modulation for comprehensive two-dimensional liquid chromatography is introduced. Modulation optimization involved a systematic investigation of heat transfer, analyte retention, and migration velocity at a range of temperatures. Longitudinal on-column thermal modulation was realized using a set of alkylphenones and compared to a conventional valve-modulator employing sample loops. The thermal modulator showed a reduced modulation-induced pressure impact than valve modulation, resulting in reduced baseline perturbation by a factor of 6; yielding a 6-14-fold improvement in signal-to-noise. A red wine sample was analyzed to demonstrate the potential of the longitudinal on-column thermal modulator for separation of a complex sample. Discrete peaks in the second dimension using the thermal modulator were 30-55% narrower than with the valve modulator. The results shown herein demonstrate the benefits of an active focusing modulator, such as reduced detection limits and increased total peak capacity.

  8. Accuracy of five serologic tests for the follow up of Strongyloides stercoralis infection.

    PubMed

    Buonfrate, Dora; Sequi, Marco; Mejia, Rojelio; Cimino, Ruben O; Krolewiecki, Alejandro J; Albonico, Marco; Degani, Monica; Tais, Stefano; Angheben, Andrea; Requena-Mendez, Ana; Muñoz, José; Nutman, Thomas B; Bisoffi, Zeno

    2015-02-01

    Traditional faecal-based methods have poor sensitivity for the detection of S. stercoralis, therefore are inadequate for post-treatment evaluation of infected patients who should be carefully monitored to exclude the persistence of the infection. In a previous study, we demonstrated high accuracy of five serology tests for the screening and diagnosis of strongyloidiasis. Aim of this study is to evaluate the performance of the same five tests for the follow up of patients infected with S. stercoralis. Retrospective study on anonymized, cryo-preserved samples available at the Centre for Tropical Diseases (Negrar, Verona, Italy). Samples were collected before and from 3 to 12 months after treatment. The samples were tested with two commercially-available ELISA tests (IVD, Bordier), two techniques based on a recombinant antigen (NIE-ELISA and NIE-LIPS) and one in-house IFAT. The results of each test were evaluated both in relation to the results of fecal examination and to those of a composite reference standard (classifying as positive a sample with positive stools and/or at least three positive serology tests). The associations between the independent variables age and time and the dependent variable value of serological test (for all five tests), were analyzed by linear mixed-effects regression model. A high proportion of samples demonstrated for each test a seroreversion or a relevant decline (optical density/relative light units halved or decrease of at least two titers for IFAT) at follow up, results confirmed by the linear mixed effects model that showed a trend to seroreversion over time for all tests. In particular, IVD-ELISA (almost 90% samples demonstrated relevant decline) and IFAT (almost 87%) had the best performance. Considering only samples with a complete negativization, NIE-ELISA showed the best performance (72.5% seroreversion). Serology is useful for the follow up of patients infected with S. stercoralis and determining test of cure.

  9. Study of probe-sample distance for biomedical spectra measurement.

    PubMed

    Wang, Bowen; Fan, Shuzhen; Li, Lei; Wang, Cong

    2011-11-02

    Fiber-based optical spectroscopy has been widely used for biomedical applications. However, the effect of probe-sample distance on the collection efficiency has not been well investigated. In this paper, we presented a theoretical model to maximize the illumination and collection efficiency in designing fiber optic probes for biomedical spectra measurement. This model was in general applicable to probes with single or multiple fibers at an arbitrary incident angle. In order to demonstrate the theory, a fluorescence spectrometer was used to measure the fluorescence of human finger skin at various probe-sample distances. The fluorescence spectrum and the total fluorescence intensity were recorded. The theoretical results show that for single fiber probes, contact measurement always provides the best results. While for multi-fiber probes, there is an optimal probe distance. When a 400- μm excitation fiber is used to deliver the light to the skin and another six 400- μm fibers surrounding the excitation fiber are used to collect the fluorescence signal, the experimental results show that human finger skin has very strong fluorescence between 475 nm and 700 nm under 450 nm excitation. The fluorescence intensity is heavily dependent on the probe-sample distance and there is an optimal probe distance. We investigated a number of probe-sample configurations and found that contact measurement could be the primary choice for single-fiber probes, but was very inefficient for multi-fiber probes. There was an optimal probe-sample distance for multi-fiber probes. By carefully choosing the probe-sample distance, the collection efficiency could be enhanced by 5-10 times. Our experiments demonstrated that the experimental results of the probe-sample distance dependence of collection efficiency in multi-fiber probes were in general agreement with our theory.

  10. Self-Efficacy for Resolving Environmental Uncertainties: Implications for Entrepreneurial Educational and Support Programs

    ERIC Educational Resources Information Center

    Pushkarskaya, Helen; Usher, Ellen L.

    2010-01-01

    Using a unique sample of rural Kentucky residents, we demonstrated that, in the domain of operational and competitive environmental uncertainties, self-efficacy beliefs are significantly higher among nascent entrepreneurs than among non-entrepreneurs. We employed the hierarchical logistic regression analysis to demonstrate that this result is…

  11. Childrearing Style of Anxiety-Disordered Parents

    ERIC Educational Resources Information Center

    Lindhout, Ingeborg; Markus, Monica; Hoogendijk, Thea; Borst, Sophie; Maingay, Ragna; Spinhoven, Philip; van Dyck, Richard; Boer, Frits

    2006-01-01

    This study investigated whether anxiety-disordered (AD) parents differ in their childrearing style from non-disordered parents. A clinical sample of 36 AD parents with children aged 6-18 was compared with a normal control sample of 36 parents. Childrearing was assessed through parent report and child report. The results demonstrated significant…

  12. Suicidal Behaviors among Adolescents in Puerto Rico: Rates and Correlates in Clinical and Community Samples

    ERIC Educational Resources Information Center

    Jones, Jennifer; Ramirez, Rafael Roberto; Davies, Mark; Canino, Glorisa; Goodwin, Renee D.

    2008-01-01

    This study examined rates and correlates of suicidal behavior among youth on the island of Puerto Rico. Data were drawn from two probability samples, one clinical (n = 736) and one community-based sample (n = 1,896), of youth ages 12 to 17. Consistent with previous studies in U.S. mainland adolescent populations, our results demonstrate that most…

  13. The Use of NanoTrap Particles as a Sample Enrichment Method to Enhance the Detection of Rift Valley Fever Virus

    PubMed Central

    Shafagati, Nazly; Narayanan, Aarthi; Baer, Alan; Fite, Katherine; Pinkham, Chelsea; Bailey, Charles; Kashanchi, Fatah; Lepene, Benjamin; Kehn-Hall, Kylene

    2013-01-01

    Background Rift Valley Fever Virus (RVFV) is a zoonotic virus that is not only an emerging pathogen but is also considered a biodefense pathogen due to the threat it may cause to public health and national security. The current state of diagnosis has led to misdiagnosis early on in infection. Here we describe the use of a novel sample preparation technology, NanoTrap particles, to enhance the detection of RVFV. Previous studies demonstrated that NanoTrap particles lead to both 100 percent capture of protein analytes as well as an improvement of more than 100-fold in sensitivity compared to existing methods. Here we extend these findings by demonstrating the capture and enrichment of viruses. Results Screening of NanoTrap particles indicated that one particle, NT53, was the most efficient at RVFV capture as demonstrated by both qRT-PCR and plaque assays. Importantly, NT53 capture of RVFV resulted in greater than 100-fold enrichment from low viral titers when other diagnostics assays may produce false negatives. NT53 was also capable of capturing and enhancing RVFV detection from serum samples. RVFV that was inactivated through either detergent or heat treatment was still found bound to NT53, indicating the ability to use NanoTrap particles for viral capture prior to transport to a BSL-2 environment. Furthermore, both NP-40-lysed virus and purified RVFV RNA were bound by NT53. Importantly, NT53 protected viral RNA from RNase A degradation, which was not observed with other commercially available beads. Incubation of RVFV samples with NT53 also resulted in increased viral stability as demonstrated through preservation of infectivity at elevated temperatures. Finally, NanoTrap particles were capable of capturing VEEV and HIV, demonstrating the broad applicability of NanoTrap particles for viral diagnostics. Conclusion This study demonstrates NanoTrap particles are capable of capturing, enriching, and protecting RVFV virions. Furthermore, the use of NanoTrap particles can be extended to a variety of viruses, including VEEV and HIV. PMID:23861988

  14. BRDF of Salt Pan Regolith Samples

    NASA Technical Reports Server (NTRS)

    Georgiev, Georgi T.; Gatebe, Charles K.; Butler, James J.; King, Michael D.

    2008-01-01

    Laboratory Bi-directional Reflectance Distribution Function (BRDF) measurements of salt pan regolith samples are presented in this study in an effort to understand the role of spatial and spectral variability of the natural biome. The samples were obtained from Etosha Pan, Namibia (19.20 deg S, 15.93 deg E, alt. 1100 m). It is shown how the BRDF depends on the measurement geometry - incident and scatter angles and on the sample particle sizes. As a demonstration of the application of the results, airborne BRDF measurements acquires with NASA's Cloud Absorption Radiometer (CAR) over the same general site where the regolith samples were collected are compared with the laboratory results. Good agreement between laboratory measured and field measured BRDF is reported.

  15. Demonstration and Verification of a Turbine Power Generation System Utilizing Renewable Fuel: Landfill Gas

    DTIC Science & Technology

    2013-09-01

    17 5.6 SAMPLING RESULTS ........................................................................................ 18 6.0 PERFORMANCE...Page ii 8.0 IMPLEMENTATION ISSUES ........................................................................................ 37 8.1 FILTRATION ...15 iv LIST OF TABLES Page Table 1. Performance results

  16. Assessment of molecular markers demonstrates concordance between samples acquired via stereotactic biopsy and open craniotomy in both anaplastic astrocytomas and glioblastomas.

    PubMed

    Gessler, Florian; Baumgarten, Peter; Bernstock, Joshua D; Harter, Patrick; Lescher, Stephanie; Senft, Christian; Seifert, Volker; Marquardt, Gerhard; Weise, Lutz

    2017-06-01

    The classification, treatment and prognosis of high-grade gliomas has been shown to correlate with the expression of molecular markers (e.g. MGMT promotor methylation and IDH1 mutations). Acquisition of tumor samples may be obtained via stereotactic biopsy or open craniotomy. Between the years 2009 and 2013, 22 patients initially diagnosed with HGGs via stereotactic biopsy, that ultimately underwent open craniotomy for resection of their tumor were prospectively included in an institutional glioma database. MGMT promotor analysis was performed using methylation-specific (MS)-PCR and IDH1R132H mutation analysis was performed using immunohistochemistry. Three patients (13.7%) exhibited IDH1R132H mutations in samples obtained via stereotactic biopsy. Tissue derived from stereotaxic biopsy was demonstrated to have MGMT promotor methylation in ten patients (45.5%), while a non-methylated MGMT promotor was demonstrated in ten patients (45.5%); inconclusive results were obtained for the remaining two patients (9%) within our cohort. The initial histologic grading, IDH1R132H mutation and MGMT promotor methylation results were confirmed using samples obtained during open craniotomy in all but one patient; here inconclusive MGMT promotor analysis was obtained in contrast to that which was obtained via stereotactic biopsy. Tumor samples acquired via stereotactic biopsy provide accurate information with regard to clinically relevant molecular markers that have been shown to impact patient care decisions. The profile of markers analyzed in our cohort was nearly concordant between those samples obtained via stereotactic biopsy or open craniotomy thereby suggesting that clinical decisions may be based on the molecular profile of the tumor samples obtained via stereotactic biopsy.

  17. Training for vigilance on the move: a video game-based paradigm for sustained attention.

    PubMed

    Szalma, J L; Daly, T N; Teo, G W L; Hancock, G M; Hancock, P A

    2018-04-01

    The capacity for superior vigilance can be trained by using knowledge of results (KR). Our present experiments demonstrate the efficacy of such training using a first-person perspective movement videogame-based platform in samples of students and Soldiers. Effectiveness was assessed by manipulating KR during a training phase and withdrawing it in a subsequent transfer phase. Relative to a no KR control condition, KR systematically improved performance for both Soldiers and students. These results build upon our previous findings that demonstrated that a video game-based platform can be used to create a movement-centred sustained attention task with important elements of traditional vigilance. The results indicate that KR effects in sustained attention extend to a first person perspective movement based paradigm, and that these effects occur in professional military as well as a more general population. Such sustained attention training can save lives and the present findings demonstrate one particular avenue to achieve this goal. Practitioner Summary: Sustained attention can be trained by means of knowledge of results using a videogame-based platform with samples of students and Soldiers. Four experiments demonstrate that a dynamic, first-person perspective video game environment can serve to support effective sustained attention training in professional military as well as a more general population.

  18. Development and Demonstration of a Method to Evaluate Bio-Sampling Strategies Using Building Simulation and Sample Planning Software

    PubMed Central

    Dols, W. Stuart; Persily, Andrew K.; Morrow, Jayne B.; Matzke, Brett D.; Sego, Landon H.; Nuffer, Lisa L.; Pulsipher, Brent A.

    2010-01-01

    In an effort to validate and demonstrate response and recovery sampling approaches and technologies, the U.S. Department of Homeland Security (DHS), along with several other agencies, have simulated a biothreat agent release within a facility at Idaho National Laboratory (INL) on two separate occasions in the fall of 2007 and the fall of 2008. Because these events constitute only two realizations of many possible scenarios, increased understanding of sampling strategies can be obtained by virtually examining a wide variety of release and dispersion scenarios using computer simulations. This research effort demonstrates the use of two software tools, CONTAM, developed by the National Institute of Standards and Technology (NIST), and Visual Sample Plan (VSP), developed by Pacific Northwest National Laboratory (PNNL). The CONTAM modeling software was used to virtually contaminate a model of the INL test building under various release and dissemination scenarios as well as a range of building design and operation parameters. The results of these CONTAM simulations were then used to investigate the relevance and performance of various sampling strategies using VSP. One of the fundamental outcomes of this project was the demonstration of how CONTAM and VSP can be used together to effectively develop sampling plans to support the various stages of response to an airborne chemical, biological, radiological, or nuclear event. Following such an event (or prior to an event), incident details and the conceptual site model could be used to create an ensemble of CONTAM simulations which model contaminant dispersion within a building. These predictions could then be used to identify priority area zones within the building and then sampling designs and strategies could be developed based on those zones. PMID:27134782

  19. Development and Demonstration of a Method to Evaluate Bio-Sampling Strategies Using Building Simulation and Sample Planning Software.

    PubMed

    Dols, W Stuart; Persily, Andrew K; Morrow, Jayne B; Matzke, Brett D; Sego, Landon H; Nuffer, Lisa L; Pulsipher, Brent A

    2010-01-01

    In an effort to validate and demonstrate response and recovery sampling approaches and technologies, the U.S. Department of Homeland Security (DHS), along with several other agencies, have simulated a biothreat agent release within a facility at Idaho National Laboratory (INL) on two separate occasions in the fall of 2007 and the fall of 2008. Because these events constitute only two realizations of many possible scenarios, increased understanding of sampling strategies can be obtained by virtually examining a wide variety of release and dispersion scenarios using computer simulations. This research effort demonstrates the use of two software tools, CONTAM, developed by the National Institute of Standards and Technology (NIST), and Visual Sample Plan (VSP), developed by Pacific Northwest National Laboratory (PNNL). The CONTAM modeling software was used to virtually contaminate a model of the INL test building under various release and dissemination scenarios as well as a range of building design and operation parameters. The results of these CONTAM simulations were then used to investigate the relevance and performance of various sampling strategies using VSP. One of the fundamental outcomes of this project was the demonstration of how CONTAM and VSP can be used together to effectively develop sampling plans to support the various stages of response to an airborne chemical, biological, radiological, or nuclear event. Following such an event (or prior to an event), incident details and the conceptual site model could be used to create an ensemble of CONTAM simulations which model contaminant dispersion within a building. These predictions could then be used to identify priority area zones within the building and then sampling designs and strategies could be developed based on those zones.

  20. Assessment of statistical uncertainty in the quantitative analysis of solid samples in motion using laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Cabalín, L. M.; González, A.; Ruiz, J.; Laserna, J. J.

    2010-08-01

    Statistical uncertainty in the quantitative analysis of solid samples in motion by laser-induced breakdown spectroscopy (LIBS) has been assessed. For this purpose, a LIBS demonstrator was designed and constructed in our laboratory. The LIBS system consisted of a laboratory-scale conveyor belt, a compact optical module and a Nd:YAG laser operating at 532 nm. The speed of the conveyor belt was variable and could be adjusted up to a maximum speed of 2 m s - 1 . Statistical uncertainty in the analytical measurements was estimated in terms of precision (reproducibility and repeatability) and accuracy. The results obtained by LIBS on shredded scrap samples under real conditions have demonstrated that the analytical precision and accuracy of LIBS is dependent on the sample geometry, position on the conveyor belt and surface cleanliness. Flat, relatively clean scrap samples exhibited acceptable reproducibility and repeatability; by contrast, samples with an irregular shape or a dirty surface exhibited a poor relative standard deviation.

  1. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing

    PubMed Central

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-01-01

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated. PMID:27196899

  2. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing.

    PubMed

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-05-17

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated.

  3. An integratable microfluidic cartridge for forensic swab samples lysis.

    PubMed

    Yang, Jianing; Brooks, Carla; Estes, Matthew D; Hurth, Cedric M; Zenhausern, Frederic

    2014-01-01

    Fully automated rapid forensic DNA analysis requires integrating several multistep processes onto a single microfluidic platform, including substrate lysis, extraction of DNA from the released lysate solution, multiplexed PCR amplification of STR loci, separation of PCR products by capillary electrophoresis, and analysis for allelic peak calling. Over the past several years, most of the rapid DNA analysis systems developed started with the reference swab sample lysate and involved an off-chip lysis of collected substrates. As a result of advancement in technology and chemistry, addition of a microfluidic module for swab sample lysis has been achieved in a few of the rapid DNA analysis systems. However, recent reports on integrated rapid DNA analysis systems with swab-in and answer-out capability lack any quantitative and qualitative characterization of the swab-in sample lysis module, which is important for downstream forensic sample processing. Maximal collection and subsequent recovery of the biological material from the crime scene is one of the first and critical steps in forensic DNA technology. Herein we present the design, fabrication and characterization of an integratable swab lysis cartridge module and the test results obtained from different types of commonly used forensic swab samples, including buccal, saliva, and blood swab samples, demonstrating the compatibility with different downstream DNA extraction chemistries. This swab lysis cartridge module is easy to operate, compatible with both forensic and microfluidic requirements, and ready to be integrated with our existing automated rapid forensic DNA analysis system. Following the characterization of the swab lysis module, an integrated run from buccal swab sample-in to the microchip CE electropherogram-out was demonstrated on the integrated prototype instrument. Therefore, in this study, we demonstrate that this swab lysis cartridge module is: (1) functionally, comparable with routine benchtop lysis, (2) compatible with various types of swab samples and chemistries, and (3) integratable to achieve a micro total analysis system (μTAS) for rapid DNA analysis. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  4. Observation of biexcitonic emission at extremely low power density in tungsten disulfide atomic layers grown on hexagonal boron nitride.

    PubMed

    Okada, Mitsuhiro; Miyauchi, Yuhei; Matsuda, Kazunari; Taniguchi, Takashi; Watanabe, Kenji; Shinohara, Hisanori; Kitaura, Ryo

    2017-03-23

    Monolayer transition metal dichalcogenides (TMDCs) including WS 2 , MoS 2 , WSe 2 and WS 2 , are two-dimensional semiconductors with direct bandgap, providing an excellent field for exploration of many-body effects in 2-dimensions (2D) through optical measurements. To fully explore the physics of TMDCs, the prerequisite is preparation of high-quality samples to observe their intrinsic properties. For this purpose, we have focused on high-quality samples, WS 2 grown by chemical vapor deposition method with hexagonal boron nitride as substrates. We observed sharp exciton emissions, whose linewidth is typically 22~23 meV, in photoluminescence spectra at room temperature, which result clearly demonstrates the high-quality of the current samples. We found that biexcitons formed with extremely low-excitation power (240 W/cm 2 ) at 80 K, and this should originate from the minimal amount of localization centers in the present high-quality samples. The results clearly demonstrate that the present samples can provide an excellent field, where one can observe various excitonic states, offering possibility of exploring optical physics in 2D and finding new condensates.

  5. Clinical and epidemiological use of nested PCR targeting the repetitive element IS1111 associated with the transposase gene from Coxiella burnetii.

    PubMed

    Mares-Guia, Maria Angélica M M; Guterres, Alexandro; Rozental, Tatiana; Ferreira, Michelle Dos Santos; Lemos, Elba R S

    Q fever is a worldwide zoonosis caused by Coxiella burnetii-a small obligate intracellular Gram-negative bacterium found in a variety of animals. It is transmitted to humans by inhalation of contaminated aerosols from urine, feces, milk, amniotic fluid, placenta, abortion products, wool, and rarely by ingestion of raw milk from infected animals. Nested PCR can improve the sensitivity and specificity of testing while offering a suitable amplicon size for sequencing. Serial dilutions were performed tenfold to test the limit of detection, and the result was 10× detection of C. burnetti DNA with internal nested PCR primers relative to trans-PCR. Different biological samples were tested and identified only in nested PCR. This demonstrates the efficiency and effectiveness of the primers. Of the 19 samples, which amplify the partial sequence of C. burnetii, 12 were positive by conventional PCR and nested PCR. Seven samples-five spleen tissue samples from rodents and two tick samples-were only positive in nested PCR. With these new internal primers for trans-PCR, we demonstrate that our nested PCR assay for C. burnetii can achieve better results than conventional PCR. Published by Elsevier Editora Ltda.

  6. Serum samples can be substituted by plasma samples for the diagnosis of paratuberculosis.

    PubMed

    Goodridge, Amador; Correa, Ricardo; Castro, Paul; Escobar, Cecilia; de Waard, Jacobus H

    2013-10-01

    Employing plasma samples rather than serum samples for serological paratuberculosis diagnosis is practical, especially when bovine TB is assessed in the same cattle herd with the gamma interferon bovine avian (IFN-γ BA) test. We demonstrate that antibody titers in serum and plasma samples, utilizing the PARACHECK(®) ELISA kit, are highly comparable (Cohen's kappa test, k=0.955). We conclude that serum can be replaced with plasma in this commercially available antibody detection assay resulting in working hour savings for sampling and blood sample work-up and cost reductions for materials and sample storage. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Real time flight simulation methodology

    NASA Technical Reports Server (NTRS)

    Parrish, E. A.; Cook, G.; Mcvey, E. S.

    1976-01-01

    An example sensitivity study is presented to demonstrate how a digital autopilot designer could make a decision on minimum sampling rate for computer specification. It consists of comparing the simulated step response of an existing analog autopilot and its associated aircraft dynamics to the digital version operating at various sampling frequencies and specifying a sampling frequency that results in an acceptable change in relative stability. In general, the zero order hold introduces phase lag which will increase overshoot and settling time. It should be noted that this solution is for substituting a digital autopilot for a continuous autopilot. A complete redesign could result in results which more closely resemble the continuous results or which conform better to original design goals.

  8. Four-point probe measurements using current probes with voltage feedback to measure electric potentials

    NASA Astrophysics Data System (ADS)

    Lüpke, Felix; Cuma, David; Korte, Stefan; Cherepanov, Vasily; Voigtländer, Bert

    2018-02-01

    We present a four-point probe resistance measurement technique which uses four equivalent current measuring units, resulting in minimal hardware requirements and corresponding sources of noise. Local sample potentials are measured by a software feedback loop which adjusts the corresponding tip voltage such that no current flows to the sample. The resulting tip voltage is then equivalent to the sample potential at the tip position. We implement this measurement method into a multi-tip scanning tunneling microscope setup such that potentials can also be measured in tunneling contact, allowing in principle truly non-invasive four-probe measurements. The resulting measurement capabilities are demonstrated for \

  9. Development of sensitive determination method for fungicides from environmental water samples with Titanate nanotube array micro-solid phase extraction prior to high performance liquid chromatography.

    PubMed

    Huang, Yunrui; Zhou, Qingxiang; Xie, Guohong

    2013-01-01

    Fungicides have been widely used throughout the world, and the resulted pollution has absorbed great attention in recent years. Present study described an effective measurement technique for fungicides including thiram, metalaxyl, diethofencarb, myclobutanil and tebuconazole in environmental water samples. A micro-solid phase extraction (μSPE) was developed utilizing ordered TiO(2) nanotube array for determination of target fungicides prior to a high performance liquid chromatography (HPLC). The experimental results indicated that TiO(2) nanotube arrays demonstrated excellent merits on the preconcentration of fungicides, and excellent linear relationship between peak area and the concentration of fungicides was obtained in the range of 0.1-50 μg L(-1). The detection limits for the targeted fungicides were in the range of 0.016-0.086 μg L(-1) (S/N=3). Four real environmental water samples were used to validate the applicability of the proposed method, and good spiked recoveries in the range of 73.9-114% were achieved. A comparison of present method with conventional solid phase extraction was made and the results exhibited that proposed method resulted in better recoveries. The results demonstrated that this μ-SPE technique was a viable alternative for the analysis of fungicides in complex samples. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. The detection of Giardia muris and Giardia lamblia cysts by immunofluorescence in animal tissues and fecal samples subjected to cycles of freezing and thawing.

    PubMed

    Erlandsen, S L; Sherlock, L A; Bemrick, W J

    1990-04-01

    The effects of freezing and thawing on the detection of selected Giardia spp. cysts were investigated using immunofluorescence, bright field microscopy, and low voltage scanning electron microscopy (SEM). Giardia muris cysts were obtained from either animal carcasses, fecal pellets, or isolated cyst preparations, whereas Giardia lamblia cysts were isolated from fecal samples. These samples were stained using an immunofluorescence technique after 1-3 freezing (-16 C) and thawing (20 C) cycles. Cysts were detected successfully by immunofluorescence in all samples. However, in those samples subjected to freeze-thawing, the cyst walls often became distorted and then were not detectable by bright field microscopy. Low voltage SEM demonstrated that the filaments in the distorted cyst wall underwent rearrangements of interfilament spacing. Quantitation of cyst recovery after freezing and thawing demonstrated that a substantial loss occurred after 1 cycle of alternating temperature when low concentrations of cysts were used, but not with high concentrations of cysts. Cyst recovery, after 3 freezing and thawing cycles, was dramatically lowered irrespective of the initial cyst concentration. These results demonstrated that immunofluorescence was an effective technique for the detection of Giardia spp. cysts in frozen samples and would suggest that freezing and thawing of fecal samples could prevent the detection of cysts when only bright field microscopy was employed.

  11. Evaluation of Two Surface Sampling Methods for Detection of Erwinia herbicola on a Variety of Materials by Culture and Quantitative PCR▿

    PubMed Central

    Buttner, Mark P.; Cruz, Patricia; Stetzenbach, Linda D.; Cronin, Tracy

    2007-01-01

    This research was designed to evaluate surface sampling protocols for use with culture and quantitative PCR (QPCR) amplification assay for detection of the gram-negative bacterial biothreat simulant Erwinia herbicola on a variety of surface materials. Surfaces selected for evaluation were wood laminate, glass and computer monitor screens, metal file cabinets, plastic arena seats, nylon seat cushions, finished concrete flooring, and vinyl tile flooring. Laboratory and test chamber studies were performed to evaluate two sampling methods, a sponge and a macrofoam swab, for detection of E. herbicola on surface materials. In laboratory trials, seven materials were inoculated with a known concentration of E. herbicola cells and samples were collected from the surfaces of the materials to determine sampling efficiencies. Culture analysis was ineffective for assessing E. herbicola collection efficiency because very few culturable cells were obtained from surface samples. QPCR demonstrated that E. herbicola DNA was present in high concentrations on all of the surface samples, and sampling efficiencies ranged from 0.7 to 52.2%, depending on the sampling method and the surface material. The swab was generally more efficient than the sponge for collection of E. herbicola from surfaces. Test chamber trials were also performed in which E. herbicola was aerosolized into the chamber and allowed to settle onto test materials. Surface sampling results supported those obtained in laboratory trials. The results of this study demonstrate the capabilities of QPCR to enhance the detection and enumeration of biocontaminants on surface materials and provide information on the comparability of sampling methods. PMID:17416685

  12. Evaluation of two surface sampling methods for detection of Erwinia herbicola on a variety of materials by culture and quantitative PCR.

    PubMed

    Buttner, Mark P; Cruz, Patricia; Stetzenbach, Linda D; Cronin, Tracy

    2007-06-01

    This research was designed to evaluate surface sampling protocols for use with culture and quantitative PCR (QPCR) amplification assay for detection of the gram-negative bacterial biothreat simulant Erwinia herbicola on a variety of surface materials. Surfaces selected for evaluation were wood laminate, glass and computer monitor screens, metal file cabinets, plastic arena seats, nylon seat cushions, finished concrete flooring, and vinyl tile flooring. Laboratory and test chamber studies were performed to evaluate two sampling methods, a sponge and a macrofoam swab, for detection of E. herbicola on surface materials. In laboratory trials, seven materials were inoculated with a known concentration of E. herbicola cells and samples were collected from the surfaces of the materials to determine sampling efficiencies. Culture analysis was ineffective for assessing E. herbicola collection efficiency because very few culturable cells were obtained from surface samples. QPCR demonstrated that E. herbicola DNA was present in high concentrations on all of the surface samples, and sampling efficiencies ranged from 0.7 to 52.2%, depending on the sampling method and the surface material. The swab was generally more efficient than the sponge for collection of E. herbicola from surfaces. Test chamber trials were also performed in which E. herbicola was aerosolized into the chamber and allowed to settle onto test materials. Surface sampling results supported those obtained in laboratory trials. The results of this study demonstrate the capabilities of QPCR to enhance the detection and enumeration of biocontaminants on surface materials and provide information on the comparability of sampling methods.

  13. Passage of scrapie to deer results in a new phenotype upon return passage to sheep

    USDA-ARS?s Scientific Manuscript database

    Aims: We previously demonstrated that scrapie has a 100% attack rate in white-tailed deer after either intracranial or oral inoculation. Samples from deer that developed scrapie had two different western blot patterns: samples derived from cerebrum had a banding pattern similar to the scrapie inocu...

  14. Exploring the Impact of Chronic Tic Disorders on Youth: Results from the Tourette Syndrome Impact Survey

    ERIC Educational Resources Information Center

    Conelea, Christine A.; Woods, Douglas W.; Zinner, Samuel H.; Budman, Cathy; Murphy, Tanya; Scahill, Lawrence D.; Compton, Scott N.; Walkup, John

    2011-01-01

    Prior research has demonstrated that chronic tic disorders (CTD) are associated with functional impairment across several domains. However, methodological limitations, such as data acquired by parental report, datasets aggregated across child and adult samples, and small treatment-seeking samples, curtail interpretation. The current study explored…

  15. Designing Intervention Studies: Selected Populations, Range Restrictions, and Statistical Power

    PubMed Central

    Miciak, Jeremy; Taylor, W. Pat; Stuebing, Karla K.; Fletcher, Jack M.; Vaughn, Sharon

    2016-01-01

    An appropriate estimate of statistical power is critical for the design of intervention studies. Although the inclusion of a pretest covariate in the test of the primary outcome can increase statistical power, samples selected on the basis of pretest performance may demonstrate range restriction on the selection measure and other correlated measures. This can result in attenuated pretest-posttest correlations, reducing the variance explained by the pretest covariate. We investigated the implications of two potential range restriction scenarios: direct truncation on a selection measure and indirect range restriction on correlated measures. Empirical and simulated data indicated direct range restriction on the pretest covariate greatly reduced statistical power and necessitated sample size increases of 82%–155% (dependent on selection criteria) to achieve equivalent statistical power to parameters with unrestricted samples. However, measures demonstrating indirect range restriction required much smaller sample size increases (32%–71%) under equivalent scenarios. Additional analyses manipulated the correlations between measures and pretest-posttest correlations to guide planning experiments. Results highlight the need to differentiate between selection measures and potential covariates and to investigate range restriction as a factor impacting statistical power. PMID:28479943

  16. Designing Intervention Studies: Selected Populations, Range Restrictions, and Statistical Power.

    PubMed

    Miciak, Jeremy; Taylor, W Pat; Stuebing, Karla K; Fletcher, Jack M; Vaughn, Sharon

    2016-01-01

    An appropriate estimate of statistical power is critical for the design of intervention studies. Although the inclusion of a pretest covariate in the test of the primary outcome can increase statistical power, samples selected on the basis of pretest performance may demonstrate range restriction on the selection measure and other correlated measures. This can result in attenuated pretest-posttest correlations, reducing the variance explained by the pretest covariate. We investigated the implications of two potential range restriction scenarios: direct truncation on a selection measure and indirect range restriction on correlated measures. Empirical and simulated data indicated direct range restriction on the pretest covariate greatly reduced statistical power and necessitated sample size increases of 82%-155% (dependent on selection criteria) to achieve equivalent statistical power to parameters with unrestricted samples. However, measures demonstrating indirect range restriction required much smaller sample size increases (32%-71%) under equivalent scenarios. Additional analyses manipulated the correlations between measures and pretest-posttest correlations to guide planning experiments. Results highlight the need to differentiate between selection measures and potential covariates and to investigate range restriction as a factor impacting statistical power.

  17. Mitigating Effects of Missing Data for SAR Coherent Images

    DOE PAGES

    Musgrove, Cameron H.; West, James C.

    2017-01-01

    Missing samples within synthetic aperture radar data result in image distortions. For coherent data products, such as coherent change detection and interferometric processing, the image distortion can be devastating to these second order products, resulting in missed detections and inaccurate height maps. Earlier approaches to repair the coherent data products focus upon reconstructing the missing data samples. This study demonstrates that reconstruction is not necessary to restore the quality of the coherent data products.

  18. Neuraminidase as an enzymatic marker for detecting airborne Influenza virus and other viruses.

    PubMed

    Turgeon, Nathalie; Toulouse, Marie-Josée; Ho, Jim; Li, Dongqing; Duchaine, Caroline

    2017-02-01

    Little information is available regarding the effectiveness of air samplers to collect viruses and regarding the effects of sampling processes on viral integrity. The neuraminidase enzyme is present on the surface of viruses that are of agricultural and medical importance. It has been demonstrated that viruses carrying this enzyme can be detected using commercial substrates without having to process the sample by methods such as RNA extraction. This project aims at evaluating the effects of 3 aerosol-sampling devices on the neuraminidase enzyme activity of airborne viruses. The purified neuraminidase enzymes from Clostridium perfringens, a strain of Influenza A (H1N1) virus, the FluMist influenza vaccine, and the Newcastle disease virus were used as models. The neuraminidase models were aerosolized in aerosol chambers and sampled with 3 different air samplers (SKC BioSampler, 3-piece cassettes with polycarbonate filters, and Coriolis μ) to assess the effect on neuraminidase enzyme activity. Our results demonstrated that Influenza virus and Newcastle disease virus neuraminidase enzymes are resistant to aerosolization and sampling with all air samplers tested. Moreover, we demonstrated that the enzymatic neuraminidase assay is as sensitive as RT-qPCR for detecting low concentrations of Influenza virus and Newcastle disease virus. Therefore, given the sensitivity of the assay and its compatibility with air sampling methods, viruses carrying the neuraminidase enzyme can be rapidly detected from air samples using neuraminidase activity assay without having to preprocess the samples.

  19. FISH-BOL and seafood identification: geographically dispersed case studies reveal systemic market substitution across Canada.

    PubMed

    Hanner, Robert; Becker, Sven; Ivanova, Natalia V; Steinke, Dirk

    2011-10-01

    The Fish Barcode of Life campaign involves a broad international collaboration among scientists working to advance the identification of fishes using DNA barcodes. With over 25% of the world's known ichthyofauna currently profiled, forensic identification of seafood products is now feasible and is becoming routine. Driven by growing consumer interest in the food supply, investigative reporters from five different media establishments procured seafood samples (n = 254) from numerous retail establishments located among five Canadian metropolitan areas between 2008 and 2010. The specimens were sent to the Canadian Centre for DNA Barcoding for analysis. By integrating the results from these individual case studies in a summary analysis, we provide a broad perspective on seafood substitution across Canada. Barcodes were recovered from 93% of the samples (n = 236), and identified using the Barcode of Life Data Systems "species identification" engine ( www.barcodinglife.org ). A 99% sequence similarity threshold was employed as a conservative matching criterion for specimen identification to the species level. Comparing these results against the Canadian Food Inspection Agency's "Fish List" a guideline to interpreting "false, misleading or deceptive" names (as per s 27 of the Fish Inspection regulations) demonstrated that 41% of the samples were mislabeled. Most samples were readily identified; however, this was not true in all cases because some samples had no close match. Others were ambiguous due to limited barcode resolution (or imperfect taxonomy) observed within a few closely related species complexes. The latter cases did not significantly impact the results because even the partial resolution achieved was sufficient to demonstrate mislabeling. This work highlights the functional utility of barcoding for the identification of diverse market samples. It also demonstrates how barcoding serves as a bridge linking scientific nomenclature with approved market names, potentially empowering regulatory bodies to enforce labeling standards. By synchronizing taxonomic effort with sequencing effort and database curation, barcoding provides a molecular identification resource of service to applied forensics.

  20. Application of advanced sampling and analysis methods to predict the structure of adsorbed protein on a material surface

    PubMed Central

    Abramyan, Tigran M.; Hyde-Volpe, David L.; Stuart, Steven J.; Latour, Robert A.

    2017-01-01

    The use of standard molecular dynamics simulation methods to predict the interactions of a protein with a material surface have the inherent limitations of lacking the ability to determine the most likely conformations and orientations of the adsorbed protein on the surface and to determine the level of convergence attained by the simulation. In addition, standard mixing rules are typically applied to combine the nonbonded force field parameters of the solution and solid phases the system to represent interfacial behavior without validation. As a means to circumvent these problems, the authors demonstrate the application of an efficient advanced sampling method (TIGER2A) for the simulation of the adsorption of hen egg-white lysozyme on a crystalline (110) high-density polyethylene surface plane. Simulations are conducted to generate a Boltzmann-weighted ensemble of sampled states using force field parameters that were validated to represent interfacial behavior for this system. The resulting ensembles of sampled states were then analyzed using an in-house-developed cluster analysis method to predict the most probable orientations and conformations of the protein on the surface based on the amount of sampling performed, from which free energy differences between the adsorbed states were able to be calculated. In addition, by conducting two independent sets of TIGER2A simulations combined with cluster analyses, the authors demonstrate a method to estimate the degree of convergence achieved for a given amount of sampling. The results from these simulations demonstrate that these methods enable the most probable orientations and conformations of an adsorbed protein to be predicted and that the use of our validated interfacial force field parameter set provides closer agreement to available experimental results compared to using standard CHARMM force field parameterization to represent molecular behavior at the interface. PMID:28514864

  1. Developmental validation of the DNAscan™ Rapid DNA Analysis™ instrument and expert system for reference sample processing.

    PubMed

    Della Manna, Angelo; Nye, Jeffrey V; Carney, Christopher; Hammons, Jennifer S; Mann, Michael; Al Shamali, Farida; Vallone, Peter M; Romsos, Erica L; Marne, Beth Ann; Tan, Eugene; Turingan, Rosemary S; Hogan, Catherine; Selden, Richard F; French, Julie L

    2016-11-01

    Since the implementation of forensic DNA typing in labs more than 20 years ago, the analysis procedures and data interpretation have always been conducted in a laboratory by highly trained and qualified scientific personnel. Rapid DNA technology has the potential to expand testing capabilities within forensic laboratories and to allow forensic STR analysis to be performed outside the physical boundaries of the traditional laboratory. The developmental validation of the DNAscan/ANDE Rapid DNA Analysis System was completed using a BioChipSet™ Cassette consumable designed for high DNA content samples, such as single source buccal swabs. A total of eight laboratories participated in the testing which totaled over 2300 swabs, and included nearly 1400 unique individuals. The goal of this extensive study was to obtain, document, analyze, and assess DNAscan and its internal Expert System to reliably genotype reference samples in a manner compliant with the FBI's Quality Assurance Standards (QAS) and the NDIS Operational Procedures. The DNAscan System provided high quality, concordant results for reference buccal swabs, including automated data analysis with an integrated Expert System. Seven external laboratories and NetBio, the developer of the technology, participated in the validation testing demonstrating the reproducibility and reliability of the system and its successful use in a variety of settings by numerous operators. The DNAscan System demonstrated limited cross reactivity with other species, was resilient in the presence of numerous inhibitors, and provided reproducible results for both buccal and purified DNA samples with sensitivity at a level appropriate for buccal swabs. The precision and resolution of the system met industry standards for detection of micro-variants and displayed single base resolution. PCR-based studies provided confidence that the system was robust and that the amplification reaction had been optimized to provide high quality results. The DNAscan integrated Expert System was examined as part of the Developmental Validation and successfully interpreted the over 2000 samples tested with over 99.998% concordant alleles. The system appropriately flagged samples for human review and failed both mixed samples and samples with insufficient genetic information. These results demonstrated the integrated Expert System makes correct allele calls without human intervention. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  2. A Simple Alternative Method for Preservation of 2-Methylisoborneol in Water Samples

    PubMed Central

    Lin, Tsair-Fuh

    2018-01-01

    2-Methylisoborneol (2-MIB) is one of the most commonly observed taste and odor (T&O) compounds present in drinking water sources. As it is biodegradable, a preservation agent, typically mercury chloride, is needed if the water is not analyzed right after sampling. Since mercury is a toxic metal, an alternative chemical that is cheaper and less toxic is desirable. In this study, two chemicals commonly used in water treatment processes, chlorine (as sodium hypochlorite) and KMnO4 (potassium permanganate), are studied to determine their feasibility as preservation agents for 2-MIB in water. Preservation experiments were first conducted in deionized water spiked with 2-MIB and with chlorine or permanganate at 4 and 25 °C. The results indicate that 2-MIB concentrations in the water samples spiked with both chemicals remained almost constant within 14 days for all the tested conditions, suggesting that oxidation and volatilization did not cause the loss of 2-MIB in the system. The experiments were further conducted for three different reservoir water samples with 30–60 ng/L of indulgent 2-MIB. The experimental results demonstrated that preservation with permanganate may have underestimated the 2-MIB concentration in the samples as a result of the formation of manganese dioxide particles in natural water and adsorption of 2-MIB onto the particles. Chlorine was demonstrated to be a good preservation agent for all three tested natural waters since oxidation of 2-MIB was negligible and biodegradation was inhibited. When the residual chlorine concentrations were controlled to be higher than 0.5 mg/L on the final day (day 14) of the experiments, the concentration reduction of 2-MIB became lower than 13% at both of the tested temperatures. The results demonstrated that sodium hypochlorite can be used as an alternative preservation agent for 2-MIB in water before analysis. PMID:29783625

  3. Lessons learned from surface wipe sampling for lead in three workplaces.

    PubMed

    Beaucham, Catherine; Ceballos, Diana; King, Bradley

    2017-08-01

    Surface wipe sampling in the occupational environment is a technique widely used by industrial hygienists. Although several organizations have promulgated standards for sampling lead and other metals, uncertainty still exists when trying to determine an appropriate wipe sampling strategy and how to interpret sampling results. Investigators from the National Institute for Occupational Safety and Health (NIOSH) Health Hazard Evaluation Program have used surface wipe sampling as part of their exposure assessment sampling strategies in a wide range of workplaces. This article discusses wipe sampling for measuring lead on surfaces in three facilities: (1) a battery recycling facility; (2) a firing range and gun store; and (3) an electronic scrap recycling facility. We summarize our findings from the facilities and what we learned by integrating wipe sampling into our sampling plan. Wiping sampling demonstrated lead in non-production surfaces in all three workplaces and that the potential that employees were taking lead home to their families existed. We also found that the presence of metals such as tin can interfere with the colorimetric results. We also discuss the advantages and disadvantages of colorimetric analysis of surface wipe samples and the challenges we faced when interpreting wipe sampling results.

  4. Comparison between active (pumped) and passive (diffusive) sampling methods for formaldehyde in pathology and histology laboratories.

    PubMed

    Lee, Eun Gyung; Magrm, Rana; Kusti, Mohannad; Kashon, Michael L; Guffey, Steven; Costas, Michelle M; Boykin, Carie J; Harper, Martin

    2017-01-01

    This study was to determine occupational exposures to formaldehyde and to compare concentrations of formaldehyde obtained by active and passive sampling methods. In one pathology and one histology laboratories, exposure measurements were collected with sets of active air samplers (Supelco LpDNPH tubes) and passive badges (ChemDisk Aldehyde Monitor 571). Sixty-six sample pairs (49 personal and 17 area) were collected and analyzed by NIOSH NMAM 2016 for active samples and OSHA Method 1007 (using the manufacturer's updated uptake rate) for passive samples. All active and passive 8-hr time-weighted average (TWA) measurements showed compliance with the OSHA permissible exposure limit (PEL-0.75 ppm) except for one passive measurement, whereas 78% for the active and 88% for the passive samples exceeded the NIOSH recommended exposure limit (REL-0.016 ppm). Overall, 73% of the passive samples showed higher concentrations than the active samples and a statistical test indicated disagreement between two methods for all data and for data without outliers. The OSHA Method cautions that passive samplers should not be used for sampling situations involving formalin solutions because of low concentration estimates in the presence of reaction products of formaldehyde and methanol (a formalin additive). However, this situation was not observed, perhaps because the formalin solutions used in these laboratories included much less methanol (3%) than those tested in the OSHA Method (up to 15%). The passive samplers in general overestimated concentrations compared to the active method, which is prudent for demonstrating compliance with an occupational exposure limit, but occasional large differences may be a result of collecting aerosolized droplets or splashes on the face of the samplers. In the situations examined in this study the passive sampler generally produces higher results than the active sampler so that a body of results from passive samplers demonstrating compliance with the OSHA PEL would be a valid conclusion. However, individual passive samples can show lower results than a paired active sampler so that a single result should be treated with caution.

  5. An optimization based sampling approach for multiple metrics uncertainty analysis using generalized likelihood uncertainty estimation

    NASA Astrophysics Data System (ADS)

    Zhou, Rurui; Li, Yu; Lu, Di; Liu, Haixing; Zhou, Huicheng

    2016-09-01

    This paper investigates the use of an epsilon-dominance non-dominated sorted genetic algorithm II (ɛ-NSGAII) as a sampling approach with an aim to improving sampling efficiency for multiple metrics uncertainty analysis using Generalized Likelihood Uncertainty Estimation (GLUE). The effectiveness of ɛ-NSGAII based sampling is demonstrated compared with Latin hypercube sampling (LHS) through analyzing sampling efficiency, multiple metrics performance, parameter uncertainty and flood forecasting uncertainty with a case study of flood forecasting uncertainty evaluation based on Xinanjiang model (XAJ) for Qing River reservoir, China. Results obtained demonstrate the following advantages of the ɛ-NSGAII based sampling approach in comparison to LHS: (1) The former performs more effective and efficient than LHS, for example the simulation time required to generate 1000 behavioral parameter sets is shorter by 9 times; (2) The Pareto tradeoffs between metrics are demonstrated clearly with the solutions from ɛ-NSGAII based sampling, also their Pareto optimal values are better than those of LHS, which means better forecasting accuracy of ɛ-NSGAII parameter sets; (3) The parameter posterior distributions from ɛ-NSGAII based sampling are concentrated in the appropriate ranges rather than uniform, which accords with their physical significance, also parameter uncertainties are reduced significantly; (4) The forecasted floods are close to the observations as evaluated by three measures: the normalized total flow outside the uncertainty intervals (FOUI), average relative band-width (RB) and average deviation amplitude (D). The flood forecasting uncertainty is also reduced a lot with ɛ-NSGAII based sampling. This study provides a new sampling approach to improve multiple metrics uncertainty analysis under the framework of GLUE, and could be used to reveal the underlying mechanisms of parameter sets under multiple conflicting metrics in the uncertainty analysis process.

  6. Saccharose solid matrix embedded proteins: a new method for sample preparation for X-ray absorption spectroscopy.

    PubMed

    Ascone, I; Sabatucci, A; Bubacco, L; Di Muro, P; Salvato, B

    2000-01-01

    In this study, solid samples of hemoglobin and hemocyanin have been prepared by embedding the proteins into a saccharose-based matrix. These materials have been developed specifically for specimens for X-ray absorption spectroscopy (XAS). The preservation of protein conformation and active site organization was tested, making comparisons between the solid and the corresponding liquid samples, using resonance Raman, infra red, fluorescence and XAS. The XAS spectra of irradiated solid and liquid samples were then compared, and the preservation of biological activity of the proteins during both preparation procedure and X-ray irradiation was assessed. In all cases, the measurements clearly demonstrate that protein solid samples are both structurally and functionally quite well preserved, much better than those in the liquid state. The saccharose matrix provides an excellent protection against X-ray damages, allowing for longer exposure to the X-ray beam. Moreover, the demonstrated long-term stability of samples permits their preparation and storage in optimal conditions, allowing for the repetition of data collection with the same sample in several experimental sessions. The very high protein concentration that can be reached results in a significantly better signal-to-noise ratio, particularly useful for high molecular weight proteins with a low metal-to-protein ratio. On the bases of the above-mentioned results, we propose the new method as a standard procedure for the preparation of biological samples to be used for XAS spectroscopy.

  7. Quantitative bioanalysis of strontium in human serum by inductively coupled plasma-mass spectrometry

    PubMed Central

    Somarouthu, Srikanth; Ohh, Jayoung; Shaked, Jonathan; Cunico, Robert L; Yakatan, Gerald; Corritori, Suzana; Tami, Joe; Foehr, Erik D

    2015-01-01

    Aim: A bioanalytical method using inductively-coupled plasma-mass spectrometry to measure endogenous levels of strontium in human serum was developed and validated. Results & methodology: This article details the experimental procedures used for the method development and validation thus demonstrating the application of the inductively-coupled plasma-mass spectrometry method for quantification of strontium in human serum samples. The assay was validated for specificity, linearity, accuracy, precision, recovery and stability. Significant endogenous levels of strontium are present in human serum samples ranging from 19 to 96 ng/ml with a mean of 34.6 ± 15.2 ng/ml (SD). Discussion & conclusion: Calibration procedures and sample pretreatment were simplified for high throughput analysis. The validation demonstrates that the method was sensitive, selective for quantification of strontium (88Sr) and is suitable for routine clinical testing of strontium in human serum samples. PMID:28031925

  8. Development of a digital microfluidic platform for point of care testing

    PubMed Central

    Sista, Ramakrishna; Hua, Zhishan; Thwar, Prasanna; Sudarsan, Arjun; Srinivasan, Vijay; Eckhardt, Allen; Pollack, Michael; Pamula, Vamsee

    2009-01-01

    Point of care testing is playing an increasingly important role in improving the clinical outcome in health care management. The salient features of a point of care device are quick results, integrated sample preparation and processing, small sample volumes, portability, multifunctionality and low cost. In this paper, we demonstrate some of these salient features utilizing an electrowetting-based Digital Microfluidic platform. We demonstrate the performance of magnetic bead-based immunoassays (cardiac troponin I) on a digital microfluidic cartridge in less than 8 minutes using whole blood samples. Using the same microfluidic cartridge, a 40-cycle real-time polymerase chain reaction was performed within 12 minutes by shuttling a droplet between two thermal zones. We further demonstrate, on the same cartridge, the capability to perform sample preparation for bacterial and fungal infectious disease pathogens (methicillin-resistance Staphylococcus aureus and Candida albicans) and for human genomic DNA using magnetic beads. In addition to rapid results and integrated sample preparation, electrowetting-based digital microfluidic instruments are highly portable because fluid pumping is performed electronically. All the digital microfluidic chips presented here were fabricated on printed circuit boards utilizing mass production techniques that keep the cost of the chip low. Due to the modularity and scalability afforded by digital microfluidics, multifunctional testing capability, such as combinations within and between immunoassays, DNA amplification, and enzymatic assays, can be brought to the point of care at a relatively low cost because a single chip can be configured in software for different assays required along the path of care. PMID:19023472

  9. Determinations of rare earth element abundance and U-Pb age of zircons using multispot laser ablation-inductively coupled plasma mass spectrometry.

    PubMed

    Yokoyama, Takaomi D; Suzuki, Toshihiro; Kon, Yoshiaki; Hirata, Takafumi

    2011-12-01

    We have developed a new calibration technique for multielement determination and U-Pb dating of zircon samples using laser ablation-inductively coupled plasma mass spectrometry (ICPMS) coupled with galvanometric optics. With the galvanometric optics, laser ablation of two or more sample materials could be achieved in very short time intervals (~10 ms). The resulting sample aerosols released from different ablation pits or different solid samples were mixed and homogenized within the sample cell and then transported into the ICP ion source. Multiple spot laser ablation enables spiking of analytes or internal standard elements directly into the solid samples, and therefore the standard addition calibration method can be applied for the determination of trace elements in solid samples. In this study, we have measured the rare earth element (REE) abundances of two zircon samples (Nancy 91500 and Prešovice) based on the standard addition technique, using a direct spiking of analytes through a multispot laser ablation of the glass standard material (NIST SRM612). The resulting REE abundance data show good agreement with previously reported values within analytical uncertainties achieved in this study (10% for most elements). Our experiments demonstrated that nonspectroscopic interferences on 14 REEs could be significantly reduced by the standard addition technique employed here. Another advantage of galvanometric devices is the accumulation of sample aerosol released from multiple spots. In this study we have measured the U-Pb age of a zircon sample (LMR) using an accumulation of sample aerosols released from 10 separate ablation pits of low diameters (~8 μm). The resulting (238)U-(206)Pb age data for the LMR zircons was 369 ± 64 Ma, which is in good agreement with previously reported age data (367.6 ± 1.5 Ma). (1) The data obtained here clearly demonstrate that the multiple spot laser ablation-ICPMS technique can become a powerful approach for elemental and isotopic ratio measurements in solid materials.

  10. Nanoparticles and Ocean Optics

    DTIC Science & Technology

    2008-01-01

    Emiliania huxleyi) and its specific viruses. We then did experiments with field samples from the Bigelow Laboratory dock as well as from shipboard...infected the coccolithophore, Emiliania huxleyi, at a rapid rate that we have never observed in a eukaryotic virus. Optical experiments demonstrated...Fig. 1-Results of infection of eukaryotic coccolithophorid, Emiliania huxleyi, with new virus isolate ø 43, which demonstrates

  11. A generic template for automated bioanalytical ligand-binding assays using modular robotic scripts in support of discovery biotherapeutic programs.

    PubMed

    Duo, Jia; Dong, Huijin; DeSilva, Binodh; Zhang, Yan J

    2013-07-01

    Sample dilution and reagent pipetting are time-consuming steps in ligand-binding assays (LBAs). Traditional automation-assisted LBAs use assay-specific scripts that require labor-intensive script writing and user training. Five major script modules were developed on Tecan Freedom EVO liquid handling software to facilitate the automated sample preparation and LBA procedure: sample dilution, sample minimum required dilution, standard/QC minimum required dilution, standard/QC/sample addition, and reagent addition. The modular design of automation scripts allowed the users to assemble an automated assay with minimal script modification. The application of the template was demonstrated in three LBAs to support discovery biotherapeutic programs. The results demonstrated that the modular scripts provided the flexibility in adapting to various LBA formats and the significant time saving in script writing and scientist training. Data generated by the automated process were comparable to those by manual process while the bioanalytical productivity was significantly improved using the modular robotic scripts.

  12. Comparison of the mucoadhesive properties of thiolated polyacrylic acid to thiolated polyallylamine.

    PubMed

    Duggan, Sarah; O'Donovan, Orla; Owens, Eleanor; Duggan, Elaine; Hughes, Helen; Cummins, Wayne

    2016-02-10

    Synthetic polymers, polyacrylic acid (PAA) and polyallylamine (PAAm), were thiolated using different methods of thiolation. Both polymers resulted in comparable thiol contents, thus allowing for the direct comparison of mucoadhesive and cohesive properties between the well-established thiolated PAA and the more novel thiolated PAAm. Thiolation of both polymers improved the swelling ability and the cohesive and mucoadhesive properties in comparison to unmodified control samples. In this study, it was shown that the swelling abilities of the thiolated PAAm sample were far greater than that of the thiolated PAA sample which, in turn, affected the drug release profile of the thiolated PAAm sample. Importantly, however, the mucoadhesive properties of thiolated PAAm were equivalent to that of the thiolated PAA sample as demonstrated by both the adhesion times on porcine intestinal tissue as measured by the rotating cylinder method and by rheological studies with a mucin solution. This study demonstrates the potential thiolated polyallylamine has as a mucoadhesive drug delivery device. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Computer code for analysing three-dimensional viscous flows in impeller passages and other duct geometries

    NASA Technical Reports Server (NTRS)

    Tatchell, D. G.

    1979-01-01

    A code, CATHY3/M, was prepared and demonstrated by application to a sample case. The preparation is reviewed, a summary of the capabilities and main features of the code is given, and the sample case results are discussed. Recommendations for future use and development of the code are provided.

  14. Emergent intraverbal responses via tact and match-to-sample instruction.

    PubMed

    Grannan, Leigh; Rehfeldt, Ruth Anne

    2012-01-01

    The present investigation evaluated the effectiveness of category tact and match-to-sample instruction in facilitating the emergence of intraverbal responses (i.e., naming several items belonging to a specific category) for 2 children with autism. Results demonstrated the emergence of untaught responses, suggesting an effective instructional protocol for establishing intraverbal responses without direct instruction.

  15. Evaluation of the technical performance of novel holotranscobalamin (holoTC) assays in a multicenter European demonstration project.

    PubMed

    Morkbak, Anne L; Heimdal, Randi M; Emmens, Kathleen; Molloy, Anne; Hvas, Anne-Mette; Schneede, Joern; Clarke, Robert; Scott, John M; Ueland, Per M; Nexo, Ebba

    2005-01-01

    A commercially available holotranscobalamin (holo-TC) radioimmunoassay (RIA) (Axis-Shield, Dundee, Scotland) was evaluated in four laboratories and compared with a holoTC ELISA run in one laboratory. The performance of the holoTC RIA assay was comparable in three of the four participating laboratories. The results from these three laboratories, involving at least 20 initial runs of "low", "medium" and "high" serum-based controls (mean holoTC concentrations 34, 60 and 110 pmol/L, respectively) yielded an intra-laboratory imprecision of 6-10%. No systematic inter-laboratory deviations were observed on runs involving 72 patient samples (holoTC concentration range 10-160 pmol/L). A fourth laboratory demonstrated higher assay imprecision for control samples and systematic deviation of results for the patient samples. Measurement of holoTC by ELISA showed an imprecision of 4-5%, and slightly higher mean values for the controls (mean holoTC concentrations 40, 70 and 114 pmol/L, respectively). Comparable results were obtained for the patient samples. The long-term intra-laboratory imprecision was 12% for the holoTC RIA and 6% for the ELISA. In conclusion, it would be prudent to check the calibration and precision prior to starting to use these holoTC assays in research or clinical practice. The results obtained using the holoTC RIA were similar to those obtained using the holoTC ELISA assay.

  16. Use of Standing Gold Nanorods for Detection of Malachite Green and Crystal Violet in Fish by SERS.

    PubMed

    Chen, Xiaowei; Nguyen, Trang H D; Gu, Liqun; Lin, Mengshi

    2017-07-01

    With growing consumption of aquaculture products, there is increasing demand on rapid and sensitive techniques that can detect prohibited substances in the seafood products. This study aimed to develop a novel surface-enhanced Raman spectroscopy (SERS) method coupled with simplified extraction protocol and novel gold nanorod (AuNR) substrates to detect banned aquaculture substances (malachite green [MG] and crystal violet [CV]) and their mixture (1:1) in aqueous solution and fish samples. Multivariate statistical tools such as principal component analysis (PCA) and partial least squares regression (PLSR) were used in data analysis. PCA results demonstrate that SERS can distinguish MG, CV and their mixture (1:1) in aqueous solution and in fish samples. The detection limit of SERS coupled with standing AuNR substrates is 1 ppb for both MG and CV in fish samples. A good linear relationship between the actual concentration and predicted concentration of analytes based on PLSR models with R 2 values from 0.87 to 0.99 were obtained, indicating satisfactory quantification results of this method. These results demonstrate that the SERS method coupled with AuNR substrates can be used for rapid and accurate detection of MG and CV in fish samples. © 2017 Institute of Food Technologists®.

  17. Laser Diffraction Techniques Replace Sieving for Lunar Soil Particle Size Distribution Data

    NASA Technical Reports Server (NTRS)

    Cooper, Bonnie L.; Gonzalez, C. P.; McKay, D. S.; Fruland, R. L.

    2012-01-01

    Sieving was used extensively until 1999 to determine the particle size distribution of lunar samples. This method is time-consuming, and requires more than a gram of material in order to obtain a result in which one may have confidence. This is demonstrated by the difference in geometric mean and median for samples measured by [1], in which a 14-gram sample produced a geometric mean of approx.52 micrometers, whereas two other samples of 1.5 grams resulted in gave means of approx.63 and approx.69 micrometers. Sample allocations for sieving are typically much smaller than a gram, and many of the sample allocations received by our lab are 0.5 to 0.25 grams in mass. Basu [2] has described how the finest fraction of the soil is easily lost in the sieving process, and this effect is compounded when sample sizes are small.

  18. A Post-Processing Receiver for the Lunar Laser Communications Demonstration Project

    NASA Technical Reports Server (NTRS)

    Srinivasan, Meera; Birnbaum, Kevin; Cheng, Michael; Quirk, Kevin

    2013-01-01

    The Lunar Laser Communications Demonstration Project undertaken by MIT Lincoln Laboratory and NASA's Goddard Space Flight Center will demonstrate high-rate laser communications from lunar orbit to the Earth. NASA's Jet Propulsion Laboratory is developing a backup ground station supporting a data rate of 39 Mbps that is based on a non-real-time software post-processing receiver architecture. This approach entails processing sample-rate-limited data without feedback in the presence high uncertainty in downlink clock characteristics under low signal flux conditions. In this paper we present a receiver concept that addresses these challenges with descriptions of the photodetector assembly, sample acquisition and recording platform, and signal processing approach. End-to-end coded simulation and laboratory data analysis results are presented that validate the receiver conceptual design.

  19. Uniform Sampling Table Method and its Applications II--Evaluating the Uniform Sampling by Experiment.

    PubMed

    Chen, Yibin; Chen, Jiaxi; Chen, Xuan; Wang, Min; Wang, Wei

    2015-01-01

    A new method of uniform sampling is evaluated in this paper. The items and indexes were adopted to evaluate the rationality of the uniform sampling. The evaluation items included convenience of operation, uniformity of sampling site distribution, and accuracy and precision of measured results. The evaluation indexes included operational complexity, occupation rate of sampling site in a row and column, relative accuracy of pill weight, and relative deviation of pill weight. They were obtained from three kinds of drugs with different shape and size by four kinds of sampling methods. Gray correlation analysis was adopted to make the comprehensive evaluation by comparing it with the standard method. The experimental results showed that the convenience of uniform sampling method was 1 (100%), odds ratio of occupation rate in a row and column was infinity, relative accuracy was 99.50-99.89%, reproducibility RSD was 0.45-0.89%, and weighted incidence degree exceeded the standard method. Hence, the uniform sampling method was easy to operate, and the selected samples were distributed uniformly. The experimental results demonstrated that the uniform sampling method has good accuracy and reproducibility, which can be put into use in drugs analysis.

  20. Ar-Ar Thermochronlogy of Apollo 12 Impact-Melt Breccia 12033,638-1

    NASA Technical Reports Server (NTRS)

    Crow, C. A.; Cassata, W. S.; Jolliff, B. L.; Ziegler, R. A.; Borg, L. E.; Shearer, C. K.

    2017-01-01

    We have undertaken an Ar-Ar thermochronology investigation as part of a coordinated multichronometer analysis of a single Apollo 12 impact- melt breccia to demonstrate the wide range of information that can be obtained for a single complex rock. This has implications for the age of formation, component makeup, and subsequent impact/shock and exposure history of the sample. This study also serves as a capabilities demonstration for the proposed MoonRise Mission [1]. The goal of this investigation is to elucidate the history of this sample through coordinated 40Ar*/39Ar, Sm-Nd, Rb-Sr and zircon 207Pb-206Pb ages along with geochemical and petrographic context on a relatively small (approximately 450 mg) sample. Here, we report preliminary results of the Ar-Ar thermochronology.

  1. Rapid combined assay for Salmonella detection in food samples.

    PubMed

    Gadó, I; Major, P; Király, M; Pláveczky, M G

    2000-01-01

    A rapid method was developed to detect salmonellae in food samples. The method gave a possibility to obtain results after 28 h 30 min. The preenrichment in buffered peptone water lasted for 6 h, the enrichment in Rappaport-Vassiliadis medium was applied for 18 h followed by PCR with INVA1-INVA2 primer pair, adapting Chiu and Ou's method. This procedure was suitable to demonstrate salmonella contamination at min. 10 cfu/25 g sample. Out of 18 samples there was a good agreement between the results of the conventional and rapid methods in case of 17 samples. PCR with SPVC1-SPVC2 primer pair informing about the presence of virulence plasmid was performed in separate tubes, because decreased sensitivity was observed in case of multiplex PCR.

  2. An assessment of Lot Quality Assurance Sampling to evaluate malaria outcome indicators: extending malaria indicator surveys

    PubMed Central

    Biedron, Caitlin; Pagano, Marcello; Hedt, Bethany L; Kilian, Albert; Ratcliffe, Amy; Mabunda, Samuel; Valadez, Joseph J

    2010-01-01

    Background Large investments and increased global prioritization of malaria prevention and treatment have resulted in greater emphasis on programme monitoring and evaluation (M&E) in many countries. Many countries currently use large multistage cluster sample surveys to monitor malaria outcome indicators on a regional and national level. However, these surveys often mask local-level variability important to programme management. Lot Quality Assurance Sampling (LQAS) has played a valuable role for local-level programme M&E. If incorporated into these larger surveys, it would provide a comprehensive M&E plan at little, if any, extra cost. Methods The Mozambique Ministry of Health conducted a Malaria Indicator Survey (MIS) in June and July 2007. We applied LQAS classification rules to the 345 sampled enumeration areas to demonstrate identifying high- and low-performing areas with respect to two malaria program indicators—‘household possession of any bednet’ and ‘household possession of any insecticide-treated bednet (ITN)’. Results As shown by the MIS, no province in Mozambique achieved the 70% coverage target for household possession of bednets or ITNs. By applying LQAS classification rules to the data, we identify 266 of the 345 enumeration areas as having bednet coverage severely below the 70% target. An additional 73 were identified with low ITN coverage. Conclusions This article demonstrates the feasibility of integrating LQAS into multistage cluster sampling surveys and using these results to support a comprehensive national, regional and local programme M&E system. Furthermore, in the recommendations we outlined how to integrate the Large Country-LQAS design into macro-surveys while still obtaining results available through current sampling practices. PMID:20139435

  3. Spent nuclear fuel integrity during dry storage - performance tests and demonstrations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKinnon, M.A.; Doherty, A.L.

    1997-06-01

    This report summarizes the results of fuel integrity surveillance determined from gas sampling during and after performance tests and demonstrations conducted from 1983 through 1996 by or in cooperation with the US DOE Office of Commercial Radioactive Waste Management (OCRWM). The cask performance tests were conducted at Idaho National Engineering Laboratory (INEL) between 1984 and 1991 and included visual observation and ultrasonic examination of the condition of the cladding, fuel rods, and fuel assembly hardware before dry storage and consolidation of fuel, and a qualitative determination of the effects of dry storage and fuel consolidation on fission gas release frommore » the spent fuel rods. The performance tests consisted of 6 to 14 runs involving one or two loading, usually three backfill environments (helium, nitrogen, and vacuum backfills), and one or two storage system orientations. The nitrogen and helium backfills were sampled and analyzed to detect leaking spent fuel rods. At the end of each performance test, periodic gas sampling was conducted on each cask. A spent fuel behavior project (i.e., enhanced surveillance, monitoring, and gas sampling activities) was initiated by DOE in 1994 for intact fuel in a CASTOR V/21 cask and for consolidated fuel in a VSC-17 cask. The results of the gas sampling activities are included in this report. Information on spent fuel integrity is of interest in evaluating the impact of long-term dry storage on the behavior of spent fuel rods. Spent fuel used during cask performance tests at INEL offers significant opportunities for confirmation of the benign nature of long-term dry storage. Supporting cask demonstration included licensing and operation of an independent spent fuel storage installation (ISFSI) at the Virginia Power (VP) Surry reactor site. A CASTOR V/21, an MC-10, and a Nuclear Assurance NAC-I28 have been loaded and placed at the VP ISFSI as part of the demonstration program. 13 refs., 14 figs., 9 tabs.« less

  4. A Tester for Carbon Nanotube Mode Lockers

    NASA Astrophysics Data System (ADS)

    Song, Yong-Won; Yamashita, Shinji

    2007-05-01

    We propose and demonstrate a tester for laser pulsating operation of carbon nanotubes employing a circulator with the extra degree of freedom of the second port to access diversified nanotube samples. The nanotubes are deposited onto the end facet of a dummy optical fiber by spray method that guarantees simple sample loading along with the minimized perturbation of optimized laser cavity condition. Resultant optical spectra, autocorrelation traces and pulse train of the laser outputs with qualified samples are presented.

  5. The RBANS Effort Index: base rates in geriatric samples.

    PubMed

    Duff, Kevin; Spering, Cynthia C; O'Bryant, Sid E; Beglinger, Leigh J; Moser, David J; Bayless, John D; Culp, Kennith R; Mold, James W; Adams, Russell L; Scott, James G

    2011-01-01

    The Effort Index (EI) of the RBANS was developed to assist clinicians in discriminating patients who demonstrate good effort from those with poor effort. However, there are concerns that older adults might be unfairly penalized by this index, which uses uncorrected raw scores. Using five independent samples of geriatric patients with a broad range of cognitive functioning (e.g., cognitively intact, nursing home residents, probable Alzheimer's disease), base rates of failure on the EI were calculated. In cognitively intact and mildly impaired samples, few older individuals were classified as demonstrating poor effort (e.g., 3% in cognitively intact). However, in the more severely impaired geriatric patients, over one third had EI scores that fell above suggested cutoff scores (e.g., 37% in nursing home residents, 33% in probable Alzheimer's disease). In the cognitively intact sample, older and less educated patients were more likely to have scores suggestive of poor effort. Education effects were observed in three of the four clinical samples. Overall cognitive functioning was significantly correlated with EI scores, with poorer cognition being associated with greater suspicion of low effort. The current results suggest that age, education, and level of cognitive functioning should be taken into consideration when interpreting EI results and that significant caution is warranted when examining EI scores in elders suspected of having dementia.

  6. Nondestructive corrosion detection in concrete through integrated heat induction and IR thermography

    NASA Astrophysics Data System (ADS)

    Kwon, Seung-Jun; Xue, Henry; Feng, Maria Q.; Baek, Seunghoon

    2011-04-01

    Steel corrosion in concrete is a main cause of deterioration and early failure of concrete structures. A novel integration of electromagnetic heat induction and infrared (IR) thermography is proposed for nondestructive detection of steel corrosion in concrete, by taking advantage of the difference in thermal characteristics of corroded and non-corroded steel. This paper focuses on experimental investigation of the concept. An inductive heater is developed to remotely heat the steel rebar from concrete surface, which is integrated with an IR camera. Bare rebar and concrete samples with different cover depths are prepared. Each concrete sample is embedded with a single steel rebar in the middle, resulting an identical cover depth from the front and the back surfaces, which enables heat induction from one surface and IR thermogrphay from the other simultaneously. The impressed current method is adopted to induce accelerated corrosion on the rebar. IR video images are recorded during both heating and cooling periods. The test results demonstrate a clear difference in thermal characteristics between corroded and non-corroded samples. The corroded samples show higher rates of heating and cooling as well as a higher peak IR intensity than those of the non-corroded samples. This study demonstrates a potential for nondestructive detection of rebar corrosion in concrete.

  7. How are mood and exercise related? Results from the Finnmark study.

    PubMed

    Sexton, H; Søgaard, A J; Olstad, R

    2001-07-01

    Recreational exercise and mood have frequently been correlated in population studies. Although it is often assumed that recreational exercise improves mood, this has not been consistently demonstrated in population studies. The relationship between mood and exercise was studied prospectively in a community sample. A series of synchronous panel models was constructed in two samples (2798 paired observations; sample I = 1219, sample II = 1498) to examine this relationship in the entire population, for women and men separately, for those with sedentary occupations, for those performing physical labour, and for those who initially showed a more dysphoric mood. Although mood and exercise were correlated, the only directional relationship that could be demonstrated was that recreational exercise had an inconsistently positive effect upon mood in those with sedentary occupations. There was no such relationship between doing physical work and mood. Analyses of those who initially showed higher levels of dysphoria did not uncover any directional relationship between mood and exercise. None of the other subgroups showed any directional effects between mood and recreational exercise, nor did the population as a whole. The relationship between exercise and mood in this population sample appears to be largely correlational in nature. This result suggests the need to take a cautious view of the role played by exercise in promoting mood in the general population.

  8. Evaluation of a gas chromatography method for azelaic acid determination in selected biological samples

    PubMed Central

    Garelnabi, Mahdi; Litvinov, Dmitry; Parthasarathy, Sampath

    2010-01-01

    Background: Azelaic acid (AzA) is the best known dicarboxilic acid to have pharmaceutical benefits and clinical applications and also to be associated with some diseases pathophysiology. Materials and Methods: We extracted and methylesterified AzA and determined its concentration in human plasma obtained from healthy individuals and also in mice fed AzA containing diet for three months. Results: AzA was detected in Gas Chromatography (GC) and confirmed by Liquid chromatography mass spectrometry (LCMS), and gas chromatography mass spectrometry (GCMC). Our results have shown that AzA can be determined efficiently in selected biological samples by GC method with 1nM limit of detection (LoD) and the limit of quantification (LoQ); was established at 50nM. Analytical Sensitivity as assayed by hexane demonstrated an analytical sensitivity at 0.050nM. The method has demonstrated 8-10% CV batch repeatability across the sample types and 13-18.9% CV for the Within-Lab Precision analysis. The method has shown that AzA can efficiently be recovered from various sample preparation including liver tissue homogenate (95%) and human plasma (97%). Conclusions: Because of its simplicity and lower limit of quantification, the present method provides a useful tool for determining AzA in various biological sample preparations. PMID:22558586

  9. Evaluation of Biological Pretreatment of Rubberwood with White Rot Fungi for Enzymatic Hydrolysis

    PubMed Central

    Nazarpour, Forough; Abdullah, Dzulkefly Kuang; Abdullah, Norhafizah; Zamiri, Reza

    2013-01-01

    The effects of biological pretreatment on the rubberwood (Hevea brasiliensis), was evaluated after cultivation of white rot fungi Ceriporiopsis subvermispora, Trametes versicolor, and a mixed culture of C. subvermispora and T. versicolor. The analysis of chemical compositions indicated that C. subvermispora had greater selectivity for lignin degradation with the highest lignin and hemicellulose loss at 45.06% and 42.08%, respectively, and lowest cellulose loss (9.50%) after 90 days among the tested samples. X-ray analysis showed that pretreated samples had a higher crystallinity than untreated samples. The sample pretreated by C. subvermispora presented the highest crystallinity of all the samples which might be caused by the selective degradation of amorphous components. Fourier transform infrared (FT-IR) spectroscopy demonstrated that the content of lignin and hemicellulose decreased during the biological pretreatment process. A study on hydrolysis of rubberwood treated with C. subvermispora, T. versicolor, and mixed culture for 90 days resulted in an increased sugar yield of about 27.67%, 16.23%, and 14.20%, respectively, as compared with untreated rubberwood (2.88%). The results obtained demonstrate that rubberwood is a potential raw material for industrial applications and white rot fungus C. subevermispora provides an effective method for improving the enzymatic hydrolysis of rubberwood. PMID:28809260

  10. Conditioning and Robustness of RNA Boltzmann Sampling under Thermodynamic Parameter Perturbations.

    PubMed

    Rogers, Emily; Murrugarra, David; Heitsch, Christine

    2017-07-25

    Understanding how RNA secondary structure prediction methods depend on the underlying nearest-neighbor thermodynamic model remains a fundamental challenge in the field. Minimum free energy (MFE) predictions are known to be "ill conditioned" in that small changes to the thermodynamic model can result in significantly different optimal structures. Hence, the best practice is now to sample from the Boltzmann distribution, which generates a set of suboptimal structures. Although the structural signal of this Boltzmann sample is known to be robust to stochastic noise, the conditioning and robustness under thermodynamic perturbations have yet to be addressed. We present here a mathematically rigorous model for conditioning inspired by numerical analysis, and also a biologically inspired definition for robustness under thermodynamic perturbation. We demonstrate the strong correlation between conditioning and robustness and use its tight relationship to define quantitative thresholds for well versus ill conditioning. These resulting thresholds demonstrate that the majority of the sequences are at least sample robust, which verifies the assumption of sampling's improved conditioning over the MFE prediction. Furthermore, because we find no correlation between conditioning and MFE accuracy, the presence of both well- and ill-conditioned sequences indicates the continued need for both thermodynamic model refinements and alternate RNA structure prediction methods beyond the physics-based ones. Copyright © 2017. Published by Elsevier Inc.

  11. A novel application of deep learning for single-lead ECG classification.

    PubMed

    Mathews, Sherin M; Kambhamettu, Chandra; Barner, Kenneth E

    2018-06-04

    Detecting and classifying cardiac arrhythmias is critical to the diagnosis of patients with cardiac abnormalities. In this paper, a novel approach based on deep learning methodology is proposed for the classification of single-lead electrocardiogram (ECG) signals. We demonstrate the application of the Restricted Boltzmann Machine (RBM) and deep belief networks (DBN) for ECG classification following detection of ventricular and supraventricular heartbeats using single-lead ECG. The effectiveness of this proposed algorithm is illustrated using real ECG signals from the widely-used MIT-BIH database. Simulation results demonstrate that with a suitable choice of parameters, RBM and DBN can achieve high average recognition accuracies of ventricular ectopic beats (93.63%) and of supraventricular ectopic beats (95.57%) at a low sampling rate of 114 Hz. Experimental results indicate that classifiers built into this deep learning-based framework achieved state-of-the art performance models at lower sampling rates and simple features when compared to traditional methods. Further, employing features extracted at a sampling rate of 114 Hz when combined with deep learning provided enough discriminatory power for the classification task. This performance is comparable to that of traditional methods and uses a much lower sampling rate and simpler features. Thus, our proposed deep neural network algorithm demonstrates that deep learning-based methods offer accurate ECG classification and could potentially be extended to other physiological signal classifications, such as those in arterial blood pressure (ABP), nerve conduction (EMG), and heart rate variability (HRV) studies. Copyright © 2018. Published by Elsevier Ltd.

  12. Concentration gradient along scala tympani following the local application of gentamicin to the round window membrane

    PubMed Central

    Plontke, Stefan K.; Mynatt, Robert; Gill, Ruth M.; Borgmann, Stefan; Salt, Alec N.

    2008-01-01

    Objectives The distribution of gentamicin along the fluid spaces of the cochlea following local applications has never previously been demonstrated. Computer simulations have predicted that significant basal-apical concentration gradients might be expected and histological studies indicate that hair cell damage is greater at the base than at the apex following local gentamicin application. In the present study, gradients of gentamicin along the cochlea were measured. Methods A recently-developed method of sampling perilymph from the cochlear apex of guinea pigs was used, in which the samples represent fluid originating from different regions along scala tympani. Gentamicin concentration was determined in sequential apical samples which were taken following up to three hours of local application to the round window niche. Results Substantial gradients of gentamicin along the length of scala tympani were demonstrated and quantified, averaging more than 4000 times greater concentration at the base compared to the apex at the time of sampling. Peak concentrations and gradients for gentamicin varied considerably between animals, likely resulting from variations in round window membrane permeability and rates of perilymph flow. Conclusions The large gradients for gentamicin demonstrated here in guinea pigs account for how it is possible to suppress vestibular function in some patients with a local application of gentamicin without damaging auditory function. Variations in round window membrane permeability and in perilymph flow could account for why hearing losses are observed in some patients. PMID:17603318

  13. Comparative study on sample stacking by moving reaction boundary formed with weak acid and weak or strong base in capillary electrophoresis: II. Experiments.

    PubMed

    Zhang, Wei; Fan, Liuyin; Shao, Jing; Li, Si; Li, Shan; Cao, Chengxi

    2011-04-15

    To demonstrate the theoretic method on the stacking of zwitterion with moving reaction boundary (MRB) in the accompanying paper, the relevant experiments were performed. The experimental results quantitatively show that (1) MRB velocity, including the comparisons between MRB and zwitterionic velocities, possesses key importance to the design of MRB stacking; (2) a much long front alkaline plug without sample should be injected before the sample injection for a complete stacking of zwitterion if sample buffer is prepared with strong base, conversely no such plug is needed if using a weak base as the sample buffer with proper concentration and pH value; (3) the presence of salt in MRB system holds dramatic effect on the MRB stacking if sample solution is a strong base, but has no effect if a weak alkali is used as sample solution; (4) all of the experiments of this paper, including the previous work, quantitatively manifest the theory and predictions shown in the accompanying paper. In addition, the so-called derivative MRB-induced re-stacking and transient FASI-induced re-stacking were also observed during the experiments, and the relevant mechanisms were briefly demonstrated with the results. The theory and its calculation procedures developed in the accompanying paper can be well used for the predictions to the MRB stacking of zwitterion in CE. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Population clustering based on copy number variations detected from next generation sequencing data.

    PubMed

    Duan, Junbo; Zhang, Ji-Gang; Wan, Mingxi; Deng, Hong-Wen; Wang, Yu-Ping

    2014-08-01

    Copy number variations (CNVs) can be used as significant bio-markers and next generation sequencing (NGS) provides a high resolution detection of these CNVs. But how to extract features from CNVs and further apply them to genomic studies such as population clustering have become a big challenge. In this paper, we propose a novel method for population clustering based on CNVs from NGS. First, CNVs are extracted from each sample to form a feature matrix. Then, this feature matrix is decomposed into the source matrix and weight matrix with non-negative matrix factorization (NMF). The source matrix consists of common CNVs that are shared by all the samples from the same group, and the weight matrix indicates the corresponding level of CNVs from each sample. Therefore, using NMF of CNVs one can differentiate samples from different ethnic groups, i.e. population clustering. To validate the approach, we applied it to the analysis of both simulation data and two real data set from the 1000 Genomes Project. The results on simulation data demonstrate that the proposed method can recover the true common CNVs with high quality. The results on the first real data analysis show that the proposed method can cluster two family trio with different ancestries into two ethnic groups and the results on the second real data analysis show that the proposed method can be applied to the whole-genome with large sample size consisting of multiple groups. Both results demonstrate the potential of the proposed method for population clustering.

  15. An assessment of Lot Quality Assurance Sampling to evaluate malaria outcome indicators: extending malaria indicator surveys.

    PubMed

    Biedron, Caitlin; Pagano, Marcello; Hedt, Bethany L; Kilian, Albert; Ratcliffe, Amy; Mabunda, Samuel; Valadez, Joseph J

    2010-02-01

    Large investments and increased global prioritization of malaria prevention and treatment have resulted in greater emphasis on programme monitoring and evaluation (M&E) in many countries. Many countries currently use large multistage cluster sample surveys to monitor malaria outcome indicators on a regional and national level. However, these surveys often mask local-level variability important to programme management. Lot Quality Assurance Sampling (LQAS) has played a valuable role for local-level programme M&E. If incorporated into these larger surveys, it would provide a comprehensive M&E plan at little, if any, extra cost. The Mozambique Ministry of Health conducted a Malaria Indicator Survey (MIS) in June and July 2007. We applied LQAS classification rules to the 345 sampled enumeration areas to demonstrate identifying high- and low-performing areas with respect to two malaria program indicators-'household possession of any bednet' and 'household possession of any insecticide-treated bednet (ITN)'. As shown by the MIS, no province in Mozambique achieved the 70% coverage target for household possession of bednets or ITNs. By applying LQAS classification rules to the data, we identify 266 of the 345 enumeration areas as having bednet coverage severely below the 70% target. An additional 73 were identified with low ITN coverage. This article demonstrates the feasibility of integrating LQAS into multistage cluster sampling surveys and using these results to support a comprehensive national, regional and local programme M&E system. Furthermore, in the recommendations we outlined how to integrate the Large Country-LQAS design into macro-surveys while still obtaining results available through current sampling practices.

  16. The Performance of ML, GLS, and WLS Estimation in Structural Equation Modeling under Conditions of Misspecification and Nonnormality.

    ERIC Educational Resources Information Center

    Olsson, Ulf Henning; Foss, Tron; Troye, Sigurd V.; Howell, Roy D.

    2000-01-01

    Used simulation to demonstrate how the choice of estimation method affects indexes of fit and parameter bias for different sample sizes when nested models vary in terms of specification error and the data demonstrate different levels of kurtosis. Discusses results for maximum likelihood (ML), generalized least squares (GLS), and weighted least…

  17. Super's Stages and the Four-Factor Structure of the Adult Career Concerns Inventory in an Australian Sample.

    ERIC Educational Resources Information Center

    Smart, Roslyn M.; Peterson, Candida C.

    1994-01-01

    Examined four-factor structure of Adult Career Concerns Inventory (ACCI) in sample of 457 employed Australians. Findings support factorial validity of ACCI by showing its congruence with Super et al.'s (1957) hypothesized 4 stages and 12 substages of career development. Results also demonstrated substantial cross-cultural support for ACCI factor…

  18. A system for measuring the pulse height distribution of ultrafast photomultipliers

    NASA Technical Reports Server (NTRS)

    Abshire, J. B.

    1977-01-01

    A system for measuring the pulse height distribution of gigahertz bandwidth photomultipliers was developed. This system uses a sampling oscilloscope as a sample-hold circuit and has a bandwidth of 12 gigahertz. Test results are given for a static crossed-filed photomultiplier tested with a demonstration system. Calculations on system amplitude resolution capabilities are included for currently available system components.

  19. The program structure does not reliably recover the correct population structure when sampling is uneven: subsampling and new estimators alleviate the problem.

    PubMed

    Puechmaille, Sebastien J

    2016-05-01

    Inferences of population structure and more precisely the identification of genetically homogeneous groups of individuals are essential to the fields of ecology, evolutionary biology and conservation biology. Such population structure inferences are routinely investigated via the program structure implementing a Bayesian algorithm to identify groups of individuals at Hardy-Weinberg and linkage equilibrium. While the method is performing relatively well under various population models with even sampling between subpopulations, the robustness of the method to uneven sample size between subpopulations and/or hierarchical levels of population structure has not yet been tested despite being commonly encountered in empirical data sets. In this study, I used simulated and empirical microsatellite data sets to investigate the impact of uneven sample size between subpopulations and/or hierarchical levels of population structure on the detected population structure. The results demonstrated that uneven sampling often leads to wrong inferences on hierarchical structure and downward-biased estimates of the true number of subpopulations. Distinct subpopulations with reduced sampling tended to be merged together, while at the same time, individuals from extensively sampled subpopulations were generally split, despite belonging to the same panmictic population. Four new supervised methods to detect the number of clusters were developed and tested as part of this study and were found to outperform the existing methods using both evenly and unevenly sampled data sets. Additionally, a subsampling strategy aiming to reduce sampling unevenness between subpopulations is presented and tested. These results altogether demonstrate that when sampling evenness is accounted for, the detection of the correct population structure is greatly improved. © 2016 John Wiley & Sons Ltd.

  20. Rapid detection of mecA and spa by the loop-mediated isothermal amplification (LAMP) method.

    PubMed

    Koide, Y; Maeda, H; Yamabe, K; Naruishi, K; Yamamoto, T; Kokeguchi, S; Takashiba, S

    2010-04-01

    To develop a detection assay for staphylococcal mecA and spa by using loop-mediated isothermal amplification (LAMP) method. Staphylococcus aureus and other related species were subjected to the detection of mecA and spa by both PCR and LAMP methods. The LAMP successfully amplified the genes under isothermal conditions at 64 degrees C within 60 min, and demonstrated identical results with the conventional PCR methods. The detection limits of the LAMP for mecA and spa, by gel electrophoresis, were 10(2) and 10 cells per tube, respectively. The naked-eye inspections were possible with 10(3) and 10 cells for detection of mecA and spa, respectively. The LAMP method was then applied to sputum and dental plaque samples. The LAMP and PCR demonstrated identical results for the plaque samples, although frequency in detection of mecA and spa by the LAMP was relatively lower for the sputum samples when compared to the PCR methods. Application of the LAMP enabled a rapid detection assay for mecA and spa. The assay may be applicable to clinical plaque samples. The LAMP offers an alternative detection assay for mecA and spa with a great advantage of the rapidity.

  1. A DUAL PLATFORM FOR SELECTIVE ANALYTE ENRICHMENT AND IONIZATION IN MASS SPECTROMETRY USING APTAMER-CONJUGATED GRAPHENE OXIDE

    PubMed Central

    Gulbakan, Basri; Yasun, Emir; Shukoor, M. Ibrahim; Zhu, Zhi; You, Mingxu; Tan, Xiaohong; Sanchez, Hernan; Powell, David H.; Dai, Hongjie; Tan, Weihong

    2010-01-01

    This study demonstrates the use of aptamer-conjugated graphene oxide as an affinity extraction and detection platform for analytes from complex biological media. We have shown that cocaine and adenosine can be selectively enriched from plasma samples and that direct mass spectrometric readout can be obtained without a matrix and with greatly improved signal-to-noise ratios. The aptamer conjugated graphene oxide has clear advantages in target enrichment and in generating highly efficient ionization of target molecules for mass spectrometry. These results demonstrate the utility of the approach for analysis of small molecules in real biological samples. PMID:21090719

  2. Single-shot time stretch stimulated Raman spectroscopy (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Saltarelli, Francesco; Kumar, Vikas; Viola, Daniele; Crisafi, Francesco; Preda, Fabrizio; Cerullo, Giulio; Polli, Dario

    2017-02-01

    Stimulated Raman scattering spectroscopy is a powerful technique for label-free molecular identification, but its broadband implementation is technically challenging. We introduce and experimentally demonstrate a novel approach based on photonic time stretch. The broadband femtosecond Stokes pulse, after interacting with the sample, is stretched by a telecom fiber to 15ns, mapping its spectrum in time. The signal is sampled through a fast analog-to-digital converter, providing single-shot spectra at 80-kHz rate. We demonstrate 10^-5 sensitivity over 500 cm-1 in the C-H region. Our results pave the way to high-speed broadband vibrational imaging for materials science and biophotonics.

  3. Characterization of cellular solids in Ti6Al4V for orthopaedic implant applications: Trabecular titanium.

    PubMed

    Marin, E; Fusi, S; Pressacco, M; Paussa, L; Fedrizzi, L

    2010-07-01

    EBM (Electron Beam Melting) technology can be used successfully to obtain cellular solids in metallic biomaterials that can greatly increase osseointegration in arthroprothesis and at the same time maintain good mechanical properties. The investigated structures, called Trabecular Titanium, usually cannot be obtained by traditional machining. Two samples: (A) with a smaller single cell area and, (B) with a bigger single cell area, were produced and studied in this project. They have been completely characterized and compared with the results in similar literature pertinent to Ti6Al4V EBM structures. Relative density was evaluated using different methods, the mean diameter of the open porosities was calculated by Scanning Electron Microscope images; the composition was evaluated using Energy-Dispersive X-Ray Spectroscopy; the microstructure (alpha-beta) was investigated using chemical etching and, the mechanical proprieties were investigated using UMTS. The mean porosity values resulted comparable with spongy bone (63% for A and 72% for B). The mean diameter of the single porosity (650 mum for A and 1400 mum for B) resulted compatible with the osseointegration data from the literature, in particular for sample A. The Vickers micro-hardness tests and the chemical etching demonstrated that the structure is fine, uniform and well distributed. The mechanical test proved that sample (A) was more resistant than sample (B), but sample (B) showed an elastic modulus almost equal to the value of spongy bone. The results of this study suggest that the two Ti6Al4V cellular solids can be used in biomedical applications to promote osseointegration demonstrating that they maybe successfully used in prosthetic implants. Additional implant results will be published in the near future. Copyright 2010 Elsevier Ltd. All rights reserved.

  4. Image re-sampling detection through a novel interpolation kernel.

    PubMed

    Hilal, Alaa

    2018-06-01

    Image re-sampling involved in re-size and rotation transformations is an essential element block in a typical digital image alteration. Fortunately, traces left from such processes are detectable, proving that the image has gone a re-sampling transformation. Within this context, we present in this paper two original contributions. First, we propose a new re-sampling interpolation kernel. It depends on five independent parameters that controls its amplitude, angular frequency, standard deviation, and duration. Then, we demonstrate its capacity to imitate the same behavior of the most frequent interpolation kernels used in digital image re-sampling applications. Secondly, the proposed model is used to characterize and detect the correlation coefficients involved in re-sampling transformations. The involved process includes a minimization of an error function using the gradient method. The proposed method is assessed over a large database of 11,000 re-sampled images. Additionally, it is implemented within an algorithm in order to assess images that had undergone complex transformations. Obtained results demonstrate better performance and reduced processing time when compared to a reference method validating the suitability of the proposed approaches. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. An improved, rapid competitive ELISA using a novel conserved 3B epitope for the detection of serum antibodies to foot-and-mouth disease virus.

    PubMed

    Chung, Chungwon J; Clavijo, Alfonso; Bounpheng, Mangkey A; Uddowla, Sabena; Sayed, Abu; Dancho, Brooke; Olesen, Ian C; Pacheco, Juan; Kamicker, Barbara J; Brake, David A; Bandaranayaka-Mudiyanselage, Carey L; Lee, Stephen S; Rai, Devendra K; Rieder, Elizabeth

    2018-06-01

    The highly contagious foot-and-mouth disease virus (FMDV) afflicts cloven-hoofed animals, resulting in significant costs because of loss of trade and recovery from disease. We developed a sensitive, specific, and rapid competitive ELISA (cELISA) to detect serum antibodies to FMDV. The cELISA utilized a monoclonal blocking antibody specific for a highly conserved FMDV nonstructural 3B epitope, a recombinant mutant FMDV 3ABC coating protein, and optimized format variables including serum incubation for 90 min at 20-25°C. Samples from 16 animals experimentally infected with one FMDV serotype (A, O, Asia, or SAT-1) demonstrated early detection capacity beginning 7 d post-inoculation. All samples from 55 vesicular stomatitis virus antibody-positive cattle and 44 samples from cloven-hoofed animals affected by non-FMD vesicular diseases were negative in the cELISA, demonstrating 100% analytical specificity. The diagnostic sensitivity was 100% against sera from 128 cattle infected with isolates of all FMDV serotypes, emphasizing serotype-agnostic results. Diagnostic specificities of U.S. cattle ( n = 1135) and swine ( n = 207) sera were 99.4% and 100%, respectively. High repeatability and reproducibility were demonstrated with 3.1% coefficient of variation in percent inhibition data and 100% agreement using 2 kit lots and 400 negative control serum samples, with no difference between bench and biosafety cabinet operation. Negative results from vaccinated, uninfected cattle, pig, and sheep sera confirmed the DIVA (differentiate infected from vaccinated animals) capability. This rapid (<3 h), select agent-free assay with high sensitivity and specificity, DIVA capability, and room temperature processing capability will serve as a useful tool in FMDV surveillance, emergency preparedness, response, and outbreak recovery programs.

  6. A Demonstration of Sample Segregation

    ERIC Educational Resources Information Center

    Fritz, Mark D.; Brumbach, Stephen B.; Hartman, JudithAnn R.

    2005-01-01

    The demonstration of sample segregation, which is simple, and visually compelling illustrates the importance of sample handling for students studying analytical chemistry and environmental chemistry. The mixture used in this demonstration has two components, which have big particle size, and different colors, which makes the segregation graphic.

  7. A Schistosoma haematobium-specific real-time PCR for diagnosis of urogenital schistosomiasis in serum samples of international travelers and migrants.

    PubMed

    Cnops, Lieselotte; Soentjens, Patrick; Clerinx, Jan; Van Esbroeck, Marjan

    2013-01-01

    Diagnosis of urogenital schistosomiasis by microscopy and serological tests may be elusive in travelers due to low egg load and the absence of seroconversion upon arrival. There is need for a more sensitive diagnostic test. Therefore, we developed a real-time PCR targeting the Schistosoma haematobium-specific Dra1 sequence. The PCR was evaluated on urine (n = 111), stool (n = 84) and serum samples (n = 135), and one biopsy from travelers and migrants with confirmed or suspected schistosomiasis. PCR revealed a positive result in 7/7 urine samples, 11/11 stool samples and 1/1 biopsy containing S. haematobium eggs as demonstrated by microscopy and in 22/23 serum samples from patients with a parasitological confirmed S. haematobium infection. S. haematobium DNA was additionally detected by PCR in 7 urine, 3 stool and 5 serum samples of patients suspected of having schistosomiasis without egg excretion in urine and feces. None of these suspected patients demonstrated other parasitic infections except one with Blastocystis hominis and Entamoeba cyst in a fecal sample. The PCR was negative in all stool samples containing S. mansoni eggs (n = 21) and in all serum samples of patients with a microscopically confirmed S. mansoni (n = 22), Ascaris lumbricoides (n = 1), Ancylostomidae (n = 1), Strongyloides stercoralis (n = 1) or Trichuris trichuria infection (n = 1). The PCR demonstrated a high specificity, reproducibility and analytical sensitivity (0.5 eggs per gram of feces). The real-time PCR targeting the Dra1 sequence for S. haematobium-specific detection in urine, feces, and particularly serum, is a promising tool to confirm the diagnosis, also during the acute phase of urogenital schistosomiasis.

  8. Developmental validation of a Nextera XT mitogenome Illumina MiSeq sequencing method for high-quality samples.

    PubMed

    Peck, Michelle A; Sturk-Andreaggi, Kimberly; Thomas, Jacqueline T; Oliver, Robert S; Barritt-Ross, Suzanne; Marshall, Charla

    2018-05-01

    Generating mitochondrial genome (mitogenome) data from reference samples in a rapid and efficient manner is critical to harnessing the greater power of discrimination of the entire mitochondrial DNA (mtDNA) marker. The method of long-range target enrichment, Nextera XT library preparation, and Illumina sequencing on the MiSeq is a well-established technique for generating mitogenome data from high-quality samples. To this end, a validation was conducted for this mitogenome method processing up to 24 samples simultaneously along with analysis in the CLC Genomics Workbench and utilizing the AQME (AFDIL-QIAGEN mtDNA Expert) tool to generate forensic profiles. This validation followed the Federal Bureau of Investigation's Quality Assurance Standards (QAS) for forensic DNA testing laboratories and the Scientific Working Group on DNA Analysis Methods (SWGDAM) validation guidelines. The evaluation of control DNA, non-probative samples, blank controls, mixtures, and nonhuman samples demonstrated the validity of this method. Specifically, the sensitivity was established at ≥25 pg of nuclear DNA input for accurate mitogenome profile generation. Unreproducible low-level variants were observed in samples with low amplicon yields. Further, variant quality was shown to be a useful metric for identifying sequencing error and crosstalk. Success of this method was demonstrated with a variety of reference sample substrates and extract types. These studies further demonstrate the advantages of using NGS techniques by highlighting the quantitative nature of heteroplasmy detection. The results presented herein from more than 175 samples processed in ten sequencing runs, show this mitogenome sequencing method and analysis strategy to be valid for the generation of reference data. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Label-free hyperspectral dark-field microscopy for quantitative scatter imaging

    NASA Astrophysics Data System (ADS)

    Cheney, Philip; McClatchy, David; Kanick, Stephen; Lemaillet, Paul; Allen, David; Samarov, Daniel; Pogue, Brian; Hwang, Jeeseong

    2017-03-01

    A hyperspectral dark-field microscope has been developed for imaging spatially distributed diffuse reflectance spectra from light-scattering samples. In this report, quantitative scatter spectroscopy is demonstrated with a uniform scattering phantom, namely a solution of polystyrene microspheres. A Monte Carlo-based inverse model was used to calculate the reduced scattering coefficients of samples of different microsphere concentrations from wavelength-dependent backscattered signal measured by the dark-field microscope. The results are compared to the measurement results from a NIST double-integrating sphere system for validation. Ongoing efforts involve quantitative mapping of scattering and absorption coefficients in samples with spatially heterogeneous optical properties.

  10. Modular Biopower System Providing Combined Heat and Power for DoD Installations

    DTIC Science & Technology

    2013-12-01

    Cycle Cost evaluation using the experimental results of the 6-month field demonstration and the system’s projected cost and performance for the...34 5.6 SAMPLING RESULTS ...premises, which resulted in a significant program delay. After a short period of operation, the custom-designed engine developed mechanical

  11. Scene recognition based on integrating active learning with dictionary learning

    NASA Astrophysics Data System (ADS)

    Wang, Chengxi; Yin, Xueyan; Yang, Lin; Gong, Chengrong; Zheng, Caixia; Yi, Yugen

    2018-04-01

    Scene recognition is a significant topic in the field of computer vision. Most of the existing scene recognition models require a large amount of labeled training samples to achieve a good performance. However, labeling image manually is a time consuming task and often unrealistic in practice. In order to gain satisfying recognition results when labeled samples are insufficient, this paper proposed a scene recognition algorithm named Integrating Active Learning and Dictionary Leaning (IALDL). IALDL adopts projective dictionary pair learning (DPL) as classifier and introduces active learning mechanism into DPL for improving its performance. When constructing sampling criterion in active learning, IALDL considers both the uncertainty and representativeness as the sampling criteria to effectively select the useful unlabeled samples from a given sample set for expanding the training dataset. Experiment results on three standard databases demonstrate the feasibility and validity of the proposed IALDL.

  12. Gel electrophoresis coupled to inductively coupled plasma-mass spectrometry using species-specific isotope dilution for iodide and iodate determination in aerosols.

    PubMed

    Brüchert, Wolfram; Helfrich, Andreas; Zinn, Nico; Klimach, Thomas; Breckheimer, Markus; Chen, Hongwei; Lai, Senchao; Hoffmann, Thorsten; Bettmer, Jörg

    2007-02-15

    In this paper, we present an online coupling of gel electrophoresis (GE) and inductively coupled plasma-mass spectrometry (ICP-MS) for the determination of iodine species (iodide and iodate) in liquid (seawater) and aerosol samples. For the first time, this approach is applied to the analysis of small molecules, and initial systematic investigations revealed that the migration behavior as well as the detection sensitivity strongly depends on the matrix (e.g., high concentrations of chloride). These effects could consequently affect the accuracy of analytical results, so that they need to be considered for the analysis of real samples. The technique used for quantification is species-specific isotope dilution analysis (ssIDA), which is a matrix-independent calibration method under certain conditions. We demonstrate that the use of 129I-enriched iodide and iodate allows the correction of the impact of the matrix on both, the electrophoretic migration and the detection sensitivity of the ICP-MS. After optimization, this coupling offers a novel and alternative method in the analysis of iodine compounds in various matrices. Here, we demonstrate the analytical capability of the technique for the chemical characterization of marine aerosols. The results show the presence of iodide and iodate at the ng m(-3) and sub-ng m(-3) level in the investigated aerosol samples, which were taken at the coastal research station in Mace Head, Ireland. These results are in good agreement with other recent studies, which demonstrated that the iodine chemistry in the marine atmosphere is only poorly understood. In addition to iodide and iodate, another iodine compound could be separated and detected in certain samples with high total iodine concentrations and was identified as elemental iodine, probably in form of triiodide, by peak matching. However, it may arise from an artifact during sample preparation.

  13. A Multilevel, Hierarchical Sampling Technique for Spatially Correlated Random Fields

    DOE PAGES

    Osborn, Sarah; Vassilevski, Panayot S.; Villa, Umberto

    2017-10-26

    In this paper, we propose an alternative method to generate samples of a spatially correlated random field with applications to large-scale problems for forward propagation of uncertainty. A classical approach for generating these samples is the Karhunen--Loève (KL) decomposition. However, the KL expansion requires solving a dense eigenvalue problem and is therefore computationally infeasible for large-scale problems. Sampling methods based on stochastic partial differential equations provide a highly scalable way to sample Gaussian fields, but the resulting parametrization is mesh dependent. We propose a multilevel decomposition of the stochastic field to allow for scalable, hierarchical sampling based on solving amore » mixed finite element formulation of a stochastic reaction-diffusion equation with a random, white noise source function. Lastly, numerical experiments are presented to demonstrate the scalability of the sampling method as well as numerical results of multilevel Monte Carlo simulations for a subsurface porous media flow application using the proposed sampling method.« less

  14. A Multilevel, Hierarchical Sampling Technique for Spatially Correlated Random Fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Osborn, Sarah; Vassilevski, Panayot S.; Villa, Umberto

    In this paper, we propose an alternative method to generate samples of a spatially correlated random field with applications to large-scale problems for forward propagation of uncertainty. A classical approach for generating these samples is the Karhunen--Loève (KL) decomposition. However, the KL expansion requires solving a dense eigenvalue problem and is therefore computationally infeasible for large-scale problems. Sampling methods based on stochastic partial differential equations provide a highly scalable way to sample Gaussian fields, but the resulting parametrization is mesh dependent. We propose a multilevel decomposition of the stochastic field to allow for scalable, hierarchical sampling based on solving amore » mixed finite element formulation of a stochastic reaction-diffusion equation with a random, white noise source function. Lastly, numerical experiments are presented to demonstrate the scalability of the sampling method as well as numerical results of multilevel Monte Carlo simulations for a subsurface porous media flow application using the proposed sampling method.« less

  15. PCR detection of Burkholderia multivorans in water and soil samples.

    PubMed

    Peeters, Charlotte; Daenekindt, Stijn; Vandamme, Peter

    2016-08-12

    Although semi-selective growth media have been developed for the isolation of Burkholderia cepacia complex bacteria from the environment, thus far Burkholderia multivorans has rarely been isolated from such samples. Because environmental B. multivorans isolates mainly originate from water samples, we hypothesized that water rather than soil is its most likely environmental niche. The aim of the present study was to assess the occurrence of B. multivorans in water samples from Flanders (Belgium) using a fast, culture-independent PCR assay. A nested PCR approach was used to achieve high sensitivity, and specificity was confirmed by sequencing the resulting amplicons. B. multivorans was detected in 11 % of the water samples (n = 112) and 92 % of the soil samples (n = 25) tested. The percentage of false positives was higher for water samples compared to soil samples, showing that the presently available B. multivorans recA primers lack specificity when applied to the analysis of water samples. The results of the present study demonstrate that B. multivorans DNA is commonly present in soil samples and to a lesser extent in water samples in Flanders (Belgium).

  16. Colorimetric-Solid Phase Extraction Technology for Water Quality Monitoring: Evaluation of C-SPE and Debubbling Methods in Microgravity

    NASA Technical Reports Server (NTRS)

    Hazen-Bosveld, April; Lipert, Robert J.; Nordling, John; Shih, Chien-Ju; Siperko, Lorraine; Porter, Marc D.; Gazda, Daniel B.; Rutz, Jeff A.; Straub, John E.; Schultz, John R.; hide

    2007-01-01

    Colorimetric-solid phase extraction (C-SPE) is being developed as a method for in-flight monitoring of spacecraft water quality. C-SPE is based on measuring the change in the diffuse reflectance spectrum of indicator disks following exposure to a water sample. Previous microgravity testing has shown that air bubbles suspended in water samples can cause uncertainty in the volume of liquid passed through the disks, leading to errors in the determination of water quality parameter concentrations. We report here the results of a recent series of C-9 microgravity experiments designed to evaluate manual manipulation as a means to collect bubble-free water samples of specified volumes from water sample bags containing up to 47% air. The effectiveness of manual manipulation was verified by comparing the results from C-SPE analyses of silver(I) and iodine performed in-flight using samples collected and debubbled in microgravity to those performed on-ground using bubble-free samples. The ground and flight results showed excellent agreement, demonstrating that manual manipulation is an effective means for collecting bubble-free water samples in microgravity.

  17. A high pressure modulated molecular beam mass spectrometric sampling system

    NASA Technical Reports Server (NTRS)

    Stearns, C. A.; Kohl, F. J.; Fryburg, G. C.; Miller, R. A.

    1977-01-01

    The current state of understanding of free-jet high pressure sampling is critically reviewed and modifications of certain theoretical and empirical considerations are presented. A high pressure, free-jet expansion, modulated molecular beam, mass spectrometric sampling apparatus was constructed and this apparatus is described in detail. Experimental studies have demonstrated that the apparatus can be used to sample high temperature systems at pressures up to one atmosphere. Condensible high temperature gaseous species have been routinely sampled and the mass spectrometric detector has provided direct identification of sampled species. System sensitivity is better than one tenth of a part per million. Experimental results obtained with argon and nitrogen beams are presented and compared to theoretical predictions. These results and the respective comparison are taken to indicate acceptable performance of the sampling apparatus. Results are also given for two groups of experiments related to hot corrosion studies. The formation of gaseous sodium sulfate in doped methane-oxygen flames was characterized and the oxidative vaporization of metals was studied in an atmospheric pressure flowing gas system to which gaseous salt partial pressures were added.

  18. Chemical synthesis of hierarchical NiCo2S4 nanosheets like nanostructure on flexible foil for a high performance supercapacitor.

    PubMed

    Kim, D -Y; Ghodake, G S; Maile, N C; Kadam, A A; Sung Lee, Dae; Fulari, V J; Shinde, S K

    2017-08-29

    In this study, hierarchical interconnected nickel cobalt sulfide (NiCo 2 S 4 ) nanosheets were effectively deposited on a flexible stainless steel foil by the chemical bath deposition method (CBD) for high-performance supercapacitor applications. The resulting NiCo 2 S 4 sample was characterized by X-ray powder diffraction (XRD), field emission scanning electron microscopy (FE-SEM), high-resolution transmission electron microscopy (HR-TEM), and electrochemical measurements. XRD and X-ray photoelectron spectroscopy (XPS) results confirmed the formation of the ternary NiCo 2 S 4 sample with a pure cubic phase. FE-SEM and HR-TEM revealed that the entire foil surface was fully covered with the interconnected nanosheets like surface morphology. The NiCo 2 S 4 nanosheets demonstrated impressive electrochemical characteristics with a specific capacitance of 1155 F g -1 at 10 mV s -1 and superior cycling stability (95% capacity after 2000 cycles). These electrochemical characteristics could be attributed to the higher active area and higher conductivity of the sample. The results demonstrated that the interconnected NiCo 2 S 4 nanosheets are promising as electrodes for supercapacitor and energy storage applications.

  19. Results Of Routine Strip Effluent Hold Tank, Decontaminated Salt Solution Hold Tank, Caustic Wash Tank And Caustic Storage Tank Samples From Modular Caustic-Side Solvent Extraction Unit During Macrobatch 6 Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, T. B.

    Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), Caustic Wash Tank (CWT) and Caustic Storage Tank (CST) samples from the Interim Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 6 have been analyzed for 238Pu, 90Sr, 137Cs, and by Inductively Coupled Plasma Emission Spectroscopy (ICPES). The Pu, Sr, and Cs results from the current Macrobatch 6 samples are similar to those from comparable samples in previous Macrobatch 5. In addition the SEHT and DSSHT heel samples (i.e. ‘preliminary’) have been analyzed and reported to meet NGS Demonstration Plan requirements. From a bulk chemical point of view, the ICPESmore » results do not vary considerably between this and the previous samples. The titanium results in the DSSHT samples continue to indicate the presence of Ti, when the feed material does not have detectable levels. This most likely indicates that leaching of Ti from MST has increased in ARP at the higher free hydroxide concentrations in the current feed.« less

  20. DNA extraction for streamlined metagenomics of diverse environmental samples.

    PubMed

    Marotz, Clarisse; Amir, Amnon; Humphrey, Greg; Gaffney, James; Gogul, Grant; Knight, Rob

    2017-06-01

    A major bottleneck for metagenomic sequencing is rapid and efficient DNA extraction. Here, we compare the extraction efficiencies of three magnetic bead-based platforms (KingFisher, epMotion, and Tecan) to a standardized column-based extraction platform across a variety of sample types, including feces, oral, skin, soil, and water. Replicate sample plates were extracted and prepared for 16S rRNA gene amplicon sequencing in parallel to assess extraction bias and DNA quality. The data demonstrate that any effect of extraction method on sequencing results was small compared with the variability across samples; however, the KingFisher platform produced the largest number of high-quality reads in the shortest amount of time. Based on these results, we have identified an extraction pipeline that dramatically reduces sample processing time without sacrificing bacterial taxonomic or abundance information.

  1. Identification of multiple mRNA and DNA sequences from small tissue samples isolated by laser-assisted microdissection.

    PubMed

    Bernsen, M R; Dijkman, H B; de Vries, E; Figdor, C G; Ruiter, D J; Adema, G J; van Muijen, G N

    1998-10-01

    Molecular analysis of small tissue samples has become increasingly important in biomedical studies. Using a laser dissection microscope and modified nucleic acid isolation protocols, we demonstrate that multiple mRNA as well as DNA sequences can be identified from a single-cell sample. In addition, we show that the specificity of procurement of tissue samples is not compromised by smear contamination resulting from scraping of the microtome knife during sectioning of lesions. The procedures described herein thus allow for efficient RT-PCR or PCR analysis of multiple nucleic acid sequences from small tissue samples obtained by laser-assisted microdissection.

  2. Health-hazard evaluation report HETA 90-390-2065 and mHETA 86-012-2065, R. T. Vanderbilt Company, Gouverneur, New York and NIOSH comments to OSHA on Variations in the Carcinogenicity of Tremolite Dust Samples of Differing Morphology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, D.P.; Sanderson, W.; Fine, L.J.

    1990-09-01

    The testimony concerned the comments of NIOSH on a manuscript entitled Variations in the Carcinogenicity of Tremolite (77536686) Dust Samples of Differing Morphology. In general the results presented in the publication have not been peer reviewed or published in the scientific literature and therefore NIOSH suggested they be viewed with caution. Appropriate controls were not included in the study, the material and methods section lacked sufficient detail to evaluate the results, and the results were presented in an awkward and confusing way. The interpretation of results for the evidence of carcinogenicity in two of the samples was questionable. Mineralogic classificationmore » of the various samples, particularly three of the samples, was unclear. To what degree the nonasbestiform varieties of tremolite used in the study represent other varieties in the world was not clear. Dose-response relationships associated with fibers from these tremolite samples were not able to be developed. In general, the results appeared to demonstrate that all forms of tremolite asbestos should be considered carcinogenic.« less

  3. Use of Enterococcus faecalis and Bacillus atrophaeus as surrogates to establish and maintain laboratory proficiency for concentration of water samples using ultrafiltration.

    PubMed

    Mapp, Latisha; Klonicki, Patricia; Takundwa, Prisca; Hill, Vincent R; Schneeberger, Chandra; Knee, Jackie; Raynor, Malik; Hwang, Nina; Chambers, Yildiz; Miller, Kenneth; Pope, Misty

    2015-11-01

    The U.S. Environmental Protection Agency's (EPA) Water Laboratory Alliance (WLA) currently uses ultrafiltration (UF) for concentration of biosafety level 3 (BSL-3) agents from large volumes (up to 100-L) of drinking water prior to analysis. Most UF procedures require comprehensive training and practice to achieve and maintain proficiency. As a result, there was a critical need to develop quality control (QC) criteria. Because select agents are difficult to work with and pose a significant safety hazard, QC criteria were developed using surrogates, including Enterococcus faecalis and Bacillus atrophaeus. This article presents the results from the QC criteria development study and results from a subsequent demonstration exercise in which E. faecalis was used to evaluate proficiency using UF to concentrate large volume drinking water samples. Based on preliminary testing EPA Method 1600 and Standard Methods 9218, for E. faecalis and B. atrophaeus respectively, were selected for use during the QC criteria development study. The QC criteria established for Method 1600 were used to assess laboratory performance during the demonstration exercise. Based on the results of the QC criteria study E. faecalis and B. atrophaeus can be used effectively to demonstrate and maintain proficiency using ultrafiltration. Published by Elsevier B.V.

  4. Numerical simulations of motion-insensitive diffusion imaging based on the distant dipolar field effects.

    PubMed

    Lin, Tao; Sun, Huijun; Chen, Zhong; You, Rongyi; Zhong, Jianhui

    2007-12-01

    Diffusion weighting in MRI is commonly achieved with the pulsed-gradient spin-echo (PGSE) method. When combined with spin-warping image formation, this method often results in ghosts due to the sample's macroscopic motion. It has been shown experimentally (Kennedy and Zhong, MRM 2004;52:1-6) that these motion artifacts can be effectively eliminated by the distant dipolar field (DDF) method, which relies on the refocusing of spatially modulated transverse magnetization by the DDF within the sample itself. In this report, diffusion-weighted images (DWIs) using both DDF and PGSE methods in the presence of macroscopic sample motion were simulated. Numerical simulation results quantify the dependence of signals in DWI on several key motion parameters and demonstrate that the DDF DWIs are much less sensitive to macroscopic sample motion than the traditional PGSE DWIs. The results also show that the dipolar correlation distance (d(c)) can alter contrast in DDF DWIs. The simulated results are in good agreement with the experimental results reported previously.

  5. A bacterial bioreporter panel to assay the cytotoxicity of atmospheric particulate matter

    NASA Astrophysics Data System (ADS)

    Kessler, Nivi; Schauer, James J.; Yagur-Kroll, Sharon; Melamed, Sahar; Tirosh, Ofir; Belkin, Shimshon; Erel, Yigal

    2012-12-01

    Numerous studies have demonstrated that elevated concentrations of suspended atmospheric particulate matter (PM) are associated with adverse health effects. In order to minimize the adverse public health effects of atmospheric PM by exposure management, there is a need for a greater understanding of the toxic mechanisms and the components that are responsible for the toxic effects. The aim of this study was to utilize bioassay techniques to investigate these aspects. For this purpose a reporter panel of 9 genetically engineered bacterial (Escherichia coli) strains was composed. Each panel member was designed to report on a different stress condition with a measurable light signal produced by the luciferase enzyme. Toxic mechanisms and components were studied using six anthropogenic PM source samples, including two vehicle combustion particles, three coal fly ash (CFA) samples and an urban dust sample. The most prominent outcome of the panel exposure results were broad panel responses observed for two of the CFA samples, indicating oxidative stress, respiration inhibition and iron deficiency. These responses were relieved when the samples were treated with EDTA, a non-specific metal chelator, suggesting the involvement of metals in the observed effects. Bioavailability analysis of the samples suggests that chromium was related to the toxic responses induced by two of the CFA samples. Oxidative stress was also observed in several samples of ambient atmospheric aerosols and excess metal toxicity in an urban dust sample collected in a parking lot. The reporter panel approach, as demonstrated in this study, has the potential of providing novel insights as to the mechanisms of atmospheric PM toxicity. Furthermore, combining the panel's results with bioavailability data can enlighten about the role of different PM components in the observed toxicity.

  6. Spectroscopic AC Susceptibility Imaging (sASI) of Magnetic Nanoparticles

    PubMed Central

    Ficko, Bradley W.; Nadar, Priyanka M.; Diamond, Solomon G.

    2014-01-01

    This study demonstrates a method for alternating current (AC) susceptibility imaging (ASI) of magnetic nanoparticles (mNPs) using low cost instrumentation. The ASI method uses AC magnetic susceptibility measurement to create tomographic images using an array of drive coils, compensation coils and fluxgate magnetometers. Using a spectroscopic approach in conjunction with ASI, a series of tomographic images can be created for each frequency measurement and is termed sASI. The advantage of sASI is that mNPs can be simultaneously characterized and imaged in a biological medium. System calibration was performed by fitting the in-phase and out-of-phase susceptibility measurements of an mNP sample with a hydrodynamic diameter of 100 nm to a Brownian relaxation model (R2 = 0.96). Samples of mNPs with core diameters of 10 and 40 nm and a sample of 100 nm hydrodynamic diameter were prepared in 0.5 ml tubes. Three mNP samples were arranged in a randomized array and then scanned using sASI with six frequencies between 425 and 925 Hz. The sASI scans showed the location and quantity of the mNP samples (R2 = 0.97). Biological compatibility of the sASI method was demonstrated by scanning mNPs that were injected into a pork sausage. The mNP response in the biological medium was found to correlate with a calibration sample (R2 = 0.97, p <0.001). These results demonstrate the concept of ASI and advantages of sASI. PMID:25477704

  7. Rasch fit statistics and sample size considerations for polytomous data.

    PubMed

    Smith, Adam B; Rush, Robert; Fallowfield, Lesley J; Velikova, Galina; Sharpe, Michael

    2008-05-29

    Previous research on educational data has demonstrated that Rasch fit statistics (mean squares and t-statistics) are highly susceptible to sample size variation for dichotomously scored rating data, although little is known about this relationship for polytomous data. These statistics help inform researchers about how well items fit to a unidimensional latent trait, and are an important adjunct to modern psychometrics. Given the increasing use of Rasch models in health research the purpose of this study was therefore to explore the relationship between fit statistics and sample size for polytomous data. Data were collated from a heterogeneous sample of cancer patients (n = 4072) who had completed both the Patient Health Questionnaire - 9 and the Hospital Anxiety and Depression Scale. Ten samples were drawn with replacement for each of eight sample sizes (n = 25 to n = 3200). The Rating and Partial Credit Models were applied and the mean square and t-fit statistics (infit/outfit) derived for each model. The results demonstrated that t-statistics were highly sensitive to sample size, whereas mean square statistics remained relatively stable for polytomous data. It was concluded that mean square statistics were relatively independent of sample size for polytomous data and that misfit to the model could be identified using published recommended ranges.

  8. Evaluation of Environmental Profiles for Reliability Demonstration

    DTIC Science & Technology

    1975-09-01

    the increase in the ram air flow rate. As a result, one cannot generalize in advance about the effect of velocity increase on air-conditioner turbine ...152 6.2.6.3 Forced Cooling Air Temperature/ Flow Schedule. 152 Sample Test Provile ....... .............. 154 6.2.8 Profiles for Multi...Profiles for Reliability Demonstration Study Flow ....... . ....... 7 2 Typical MIL-STD-781 Profile ................ 23 3 Test Cycle A - Ambient Cooled

  9. Sample preparation of metal alloys by electric discharge machining

    NASA Technical Reports Server (NTRS)

    Chapman, G. B., II; Gordon, W. A.

    1976-01-01

    Electric discharge machining was investigated as a noncontaminating method of comminuting alloys for subsequent chemical analysis. Particulate dispersions in water were produced from bulk alloys at a rate of about 5 mg/min by using a commercially available machining instrument. The utility of this approach was demonstrated by results obtained when acidified dispersions were substituted for true acid solutions in an established spectrochemical method. The analysis results were not significantly different for the two sample forms. Particle size measurements and preliminary results from other spectrochemical methods which require direct aspiration of liquid into flame or plasma sources are reported.

  10. 40 CFR Table 3 to Subpart Yyyy of... - Requirements for Performance Tests and Initial Compliance Demonstrations

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the Administrator formaldehyde concentration must be corrected to 15 percent O2, dry basis. Results of... 100 percent load. b. select the sampling port location and the number of traverse points AND Method 1... concentration at the sampling port location AND Method 3A or 3B of 40 CFR part 60, appendix A measurements to...

  11. Stringent and efficient assessment of boson-sampling devices.

    PubMed

    Tichy, Malte C; Mayer, Klaus; Buchleitner, Andreas; Mølmer, Klaus

    2014-07-11

    Boson sampling holds the potential to experimentally falsify the extended Church-Turing thesis. The computational hardness of boson sampling, however, complicates the certification that an experimental device yields correct results in the regime in which it outmatches classical computers. To certify a boson sampler, one needs to verify quantum predictions and rule out models that yield these predictions without true many-boson interference. We show that a semiclassical model for many-boson propagation reproduces coarse-grained observables that are proposed as witnesses of boson sampling. A test based on Fourier matrices is demonstrated to falsify physically plausible alternatives to coherent many-boson propagation.

  12. Probabilistic models, learning algorithms, and response variability: sampling in cognitive development.

    PubMed

    Bonawitz, Elizabeth; Denison, Stephanie; Griffiths, Thomas L; Gopnik, Alison

    2014-10-01

    Although probabilistic models of cognitive development have become increasingly prevalent, one challenge is to account for how children might cope with a potentially vast number of possible hypotheses. We propose that children might address this problem by 'sampling' hypotheses from a probability distribution. We discuss empirical results demonstrating signatures of sampling, which offer an explanation for the variability of children's responses. The sampling hypothesis provides an algorithmic account of how children might address computationally intractable problems and suggests a way to make sense of their 'noisy' behavior. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Dientamoeba fragilis in swine population: a preliminary investigation.

    PubMed

    Crotti, D; Sensi, M; Crotti, S; Grelloni, V; Manuali, E

    2007-04-30

    Dientamoeba fragilis, a protozoan with worldwide distribution is considered to be responsible for enteric disease in humans. A wide spectrum of clinical symptoms including; diarrhoea (acute or prolonged), flatulence, abdominal pains and other unspecific bowel symptoms have been ascribed to this parasite. Asymptomatic infection has also been reported. Dientamoeba fragilis is as its name indicates an extremely delicate protozoon and only the trophozoite has ever been demonstrated in stool samples. The definitive diagnosis of this infection is based on demonstration in permanently stained stool samples. In Italy examination of ova and parasite (O&P) samples are not currently performed. This protozoan is extremely difficult to cultivate but molecular techniques such as the Polymerase Chain Reaction offer promise as a means of diagnosing infection. The epidemiology of Dientamoebiasis is not clear. This paper will present preliminary results from a study looking for the parasite's presence in swine faeces. The possible role of pigs as a reservoir of infection was studied; 121 faecal samples from breeding and fattening pigs were examined using a Giemsa permanent stain. Dientamoeba fragilis was found in 53 (43.8%) of the stool samples examined.

  14. A Multi-Omics Approach to Evaluate the Quality of Milk Whey Used in Ricotta Cheese Production

    PubMed Central

    Sattin, Eleonora; Andreani, Nadia A.; Carraro, Lisa; Lucchini, Rosaria; Fasolato, Luca; Telatin, Andrea; Balzan, Stefania; Novelli, Enrico; Simionati, Barbara; Cardazzo, Barbara

    2016-01-01

    In the past, milk whey was only a by-product of cheese production, but currently, it has a high commercial value for use in the food industries. However, the regulation of whey management (i.e., storage and hygienic properties) has not been updated, and as a consequence, its microbiological quality is very challenging for food safety. The Next Generation Sequencing (NGS) technique was applied to several whey samples used for Ricotta production to evaluate the microbial community composition in depth using both RNA and DNA as templates for NGS library construction. Whey samples demonstrating a high microbial and aerobic spore load contained mostly Firmicutes; although variable, some samples contained a relevant amount of Gammaproteobacteria. Several lots of whey acquired as raw material for Ricotta production presented defective organoleptic properties. To define the volatile compounds in normal and defective whey samples, a headspace gas chromatography/mass spectrometry (GC/MS) analysis was conducted. The statistical analysis demonstrated that different microbial communities resulted from DNA or cDNA library sequencing, and distinguishable microbiota composed the communities contained in the organoleptic-defective whey samples. PMID:27582735

  15. Determination of the botanical origin of honey by front-face synchronous fluorescence spectroscopy.

    PubMed

    Lenhardt, Lea; Zeković, Ivana; Dramićanin, Tatjana; Dramićanin, Miroslav D; Bro, Rasmus

    2014-01-01

    Front-face synchronous fluorescence spectroscopy combined with chemometrics is used to classify honey samples according to their botanical origin. Synchronous fluorescence spectra of three monofloral (linden, sunflower, and acacia), polyfloral (meadow mix), and fake (fake acacia and linden) honey types (109 samples) were collected in an excitation range of 240-500 nm for synchronous wavelength intervals of 30-300 nm. Chemometric analysis of the gathered data included principal component analysis and partial least squares discriminant analysis. Mean cross-validated classification errors of 0.2 and 4.8% were found for a model that accounts only for monofloral samples and for a model that includes both the monofloral and polyfloral groups, respectively. The results demonstrate that single synchronous fluorescence spectra of different honeys differ significantly because of their distinct physical and chemical characteristics and provide sufficient data for the clear differentiation among honey groups. The spectra of fake honey samples showed pronounced differences from those of genuine honey, and these samples are easily recognized on the basis of their synchronous fluorescence spectra. The study demonstrated that this method is a valuable and promising technique for honey authentication.

  16. An empirical comparison of isolate-based and sample-based definitions of antimicrobial resistance and their effect on estimates of prevalence.

    PubMed

    Humphry, R W; Evans, J; Webster, C; Tongue, S C; Innocent, G T; Gunn, G J

    2018-02-01

    Antimicrobial resistance is primarily a problem in human medicine but there are unquantified links of transmission in both directions between animal and human populations. Quantitative assessment of the costs and benefits of reduced antimicrobial usage in livestock requires robust quantification of transmission of resistance between animals, the environment and the human population. This in turn requires appropriate measurement of resistance. To tackle this we selected two different methods for determining whether a sample is resistant - one based on screening a sample, the other on testing individual isolates. Our overall objective was to explore the differences arising from choice of measurement. A literature search demonstrated the widespread use of testing of individual isolates. The first aim of this study was to compare, quantitatively, sample level and isolate level screening. Cattle or sheep faecal samples (n=41) submitted for routine parasitology were tested for antimicrobial resistance in two ways: (1) "streak" direct culture onto plates containing the antimicrobial of interest; (2) determination of minimum inhibitory concentration (MIC) of 8-10 isolates per sample compared to published MIC thresholds. Two antibiotics (ampicillin and nalidixic acid) were tested. With ampicillin, direct culture resulted in more than double the number of resistant samples than the MIC method based on eight individual isolates. The second aim of this study was to demonstrate the utility of the observed relationship between these two measures of antimicrobial resistance to re-estimate the prevalence of antimicrobial resistance from a previous study, in which we had used "streak" cultures. Boot-strap methods were used to estimate the proportion of samples that would have tested resistant in the historic study, had we used the isolate-based MIC method instead. Our boot-strap results indicate that our estimates of prevalence of antimicrobial resistance would have been considerably lower in the historic study had the MIC method been used. Finally we conclude that there is no single way of defining a sample as resistant to an antimicrobial agent. The method used greatly affects the estimated prevalence of antimicrobial resistance in a sampled population of animals, thus potentially resulting in misleading results. Comparing methods on the same samples allows us to re-estimate the prevalence from other studies, had other methods for determining resistance been used. The results of this study highlight the importance of establishing what the most appropriate measure of antimicrobial resistance is, for the proposed purpose of the results. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. MICROARRAY QUALITY CONTROL PROJECT: A COMPREHENSIVE GENE EXPRESSION TECHNOLOGY SURVEY DEMONSTRATES MEASURABLE CONSISTENCY AND CONCORDANT RESULTS BETWEEN PLATFORMS

    EPA Science Inventory

    Over the last decade, the introduction of microarray technology has had a profound impact on gene expression research. The publication of studies with dissimilar or altogether contradictory results, obtained using different microarray platforms to analyze identical RNA samples, h...

  18. Multiplexed operation of a micromachined ultrasonic droplet ejector array.

    PubMed

    Forbes, Thomas P; Degertekin, F Levent; Fedorov, Andrei G

    2007-10-01

    A dual-sample ultrasonic droplet ejector array is developed for use as a soft-ionization ion source for multiplexed mass spectrometry (MS). Such a multiplexed ion source aims to reduce MS analysis time for multiple analyte streams, as well as allow for the synchronized ejection of the sample(s) and an internal standard for quantitative results and mass calibration. Multiplexing is achieved at the device level by division of the fluid reservoir and separating the active electrodes of the piezoelectric transducer for isolated application of ultrasonic wave energy to each domain. The transducer is mechanically shaped to further reduce the acoustical crosstalk between the domains. Device design is performed using finite-element analysis simulations and supported by experimental characterization. Isolated ejection of approximately 5 microm diameter water droplets from individual domains in the micromachined droplet ejector array at around 1 MHz frequency is demonstrated by experiments. The proof-of-concept demonstration using a dual-sample device also shows potential for multiplexing with larger numbers of analytes.

  19. Multiplexed operation of a micromachined ultrasonic droplet ejector array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Forbes, Thomas P.; Degertekin, F. Levent; Fedorov, Andrei G.

    2007-10-15

    A dual-sample ultrasonic droplet ejector array is developed for use as a soft-ionization ion source for multiplexed mass spectrometry (MS). Such a multiplexed ion source aims to reduce MS analysis time for multiple analyte streams, as well as allow for the synchronized ejection of the sample(s) and an internal standard for quantitative results and mass calibration. Multiplexing is achieved at the device level by division of the fluid reservoir and separating the active electrodes of the piezoelectric transducer for isolated application of ultrasonic wave energy to each domain. The transducer is mechanically shaped to further reduce the acoustical crosstalk betweenmore » the domains. Device design is performed using finite-element analysis simulations and supported by experimental characterization. Isolated ejection of {approx}5 {mu}m diameter water droplets from individual domains in the micromachined droplet ejector array at around 1 MHz frequency is demonstrated by experiments. The proof-of-concept demonstration using a dual-sample device also shows potential for multiplexing with larger numbers of analytes.« less

  20. Effect of solution treatment on the fatigue behavior of an as-forged Mg-Zn-Y-Zr alloy

    NASA Astrophysics Data System (ADS)

    Wang, S. D.; Xu, D. K.; Wang, B. J.; Han, E. H.; Dong, C.

    2016-04-01

    Through investigating and comparing the fatigue behavior of an as-forged Mg-6.7Zn-1.3Y-0.6Zr (wt.%) alloy before and after solid solution treatment (T4) in laboratory air, the effect of T4 treatment on fatigue crack initiation was disclosed. S-N curves illustrated that the fatigue strength of as-forged samples was 110 MPa, whereas the fatigue strength of T4 samples was only 80 MPa. Observations to fracture surfaces demonstrated that for as-forged samples, fatigue crack initiation sites were covered with a layer of oxide film. However, due to the coarse grain structure and the dissolution of MgZn2 precipitates, the activation and accumulation of {10-12} twins in T4 samples were much easier, resulting in the preferential fatigue crack initiation at cracked twin boundaries (TBs). Surface characterization demonstrated that TB cracking was mainly ascribed to the incompatible plastic deformation in the twinned area and nearby α-Mg matrix.

  1. Super-Eddington accreting massive black holes as long-lived cosmological standards.

    PubMed

    Wang, Jian-Min; Du, Pu; Valls-Gabaud, David; Hu, Chen; Netzer, Hagai

    2013-02-22

    Super-Eddington accreting massive black holes (SEAMBHs) reach saturated luminosities above a certain accretion rate due to photon trapping and advection in slim accretion disks. We show that these SEAMBHs could provide a new tool for estimating cosmological distances if they are properly identified by hard x-ray observations, in particular by the slope of their 2-10 keV continuum. To verify this idea we obtained black hole mass estimates and x-ray data for a sample of 60 narrow line Seyfert 1 galaxies that we consider to be the most promising SEAMBH candidates. We demonstrate that the distances derived by the new method for the objects in the sample get closer to the standard luminosity distances as the hard x-ray continuum gets steeper. The results allow us to analyze the requirements for using the method in future samples of active black holes and to demonstrate that the expected uncertainty, given large enough samples, can make them into a useful, new cosmological ruler.

  2. Evaluation of magnesium ions release, biocorrosion, and hemocompatibility of MAO/PLLA-modified magnesium alloy WE42.

    PubMed

    Lu, Ping; Cao, Lu; Liu, Yin; Xu, Xinhua; Wu, Xiangfeng

    2011-01-01

    Magnesium alloys may potentially be applied as biodegradable metallic materials in cardiovascular stent. However, the high corrosion rate hinders its clinical application. In this study, a new approach was adopted to control the corrosion rate by fabricating a biocompatible micro-arc oxidation/poly-L-lactic acid (MAO/PLLA) composite coating on the magnesium alloy WE42 substrate and the biocompatibility of the modified samples was investigated. The scanning electronic microscope (SEM) images were used to demonstrate the morphology of the samples before and after being submerged in hanks solution for 4 weeks. The degradation was evaluated through the magnesium ions release rate and electrochemical impedance spectroscopy (EIS) test. The biocompatibility of the samples was demonstrated by coagulation time and hemolysis behavior. The result shows that the poly-L-lactic acid (PLLA) effectively improved the corrosion resistance by sealing the microcracks and microholes on the surface of the MAO coating. The modified samples had good compatibility. © 2010 Wiley Periodicals, Inc.

  3. The low-temperature method for study of coniferous tissues in the environmental scanning electron microscope.

    PubMed

    Neděla, Vilém; Tihlaříková, Eva; Hřib, Jiří

    2015-01-01

    The use of non-standard low-temperature conditions in environmental scanning electron microscopy might be promising for the observation of coniferous tissues in their native state. This study is aimed to analyse and evaluate the method based on the principle of low-temperature sample stabilization. We demonstrate that the upper mucous layer is sublimed and a microstructure of the sample surface can be observed with higher resolution at lower gas pressure conditions, thanks to a low-temperature method. An influence of the low-temperature method on sample stability was also studied. The results indicate that high-moisture conditions are not suitable for this method and often cause the collapse of samples. The potential improvement of stability to beam damage has been demonstrated by long-time observation at different operation parameters. We finally show high applicability of the low-temperature method on different types of conifers and Oxalis acetosella. © 2014 Wiley Periodicals, Inc.

  4. Quantitation of active pharmaceutical ingredients and excipients in powder blends using designed multivariate calibration models by near-infrared spectroscopy.

    PubMed

    Li, Weiyong; Worosila, Gregory D

    2005-05-13

    This research note demonstrates the simultaneous quantitation of a pharmaceutical active ingredient and three excipients in a simulated powder blend containing acetaminophen, Prosolv and Crospovidone. An experimental design approach was used in generating a 5-level (%, w/w) calibration sample set that included 125 samples. The samples were prepared by weighing suitable amount of powders into separate 20-mL scintillation vials and were mixed manually. Partial least squares (PLS) regression was used in calibration model development. The models generated accurate results for quantitation of Crospovidone (at 5%, w/w) and magnesium stearate (at 0.5%, w/w). Further testing of the models demonstrated that the 2-level models were as effective as the 5-level ones, which reduced the calibration sample number to 50. The models had a small bias for quantitation of acetaminophen (at 30%, w/w) and Prosolv (at 64.5%, w/w) in the blend. The implication of the bias is discussed.

  5. Occurrence of marine algal toxins in oyster and phytoplankton samples in Daya Bay, South China Sea.

    PubMed

    Jiang, Tao; Liu, Lei; Li, Yang; Zhang, Jing; Tan, Zhijun; Wu, Haiyan; Jiang, Tianjiu; Lu, Songhui

    2017-09-01

    The occurrence and seasonal variations of marine algal toxins in phytoplankton and oyster samples in Daya Bay (DYB), South China Sea were investigated. Two Dinophysis species, namely, D. caudata and D. acuminata complex, were identified as Okadaic acid (OA)/pectenotoxin (PTX) related species. Liquid chromatography with tandem mass spectrometry (LC-MS/MS) analysis demonstrated that 2.04-14.47 pg PTX2 per cell was the predominant toxin in single-cell isolates of D. caudata. D. acuminata was not subjected to toxin analysis. The occurrence of OAs in phytoplankton concentrates of net-haul sample coincided with the presence of D. accuminata complex, suggesting that this species is most likely an OA producer in this sea area. OA, dinophysistoxins-1 (DTX1), PTX2, PTX2sa, gymnodimine (GYM), homoyessotoxin (homoYTX), and domoic acid (DA) demonstrated positive results in net haul samples. To our best knowledge, this paper is the first to report the detection of GYM, DA, and homoYTX in phytoplankton samples in Chinese coastal waters. Among the algal toxins, GYM demonstrated the highest frequency of positive detections in phytoplankton concentrates (13/17). Five compounds of algal toxins, including OA, DTX1, PTX2, PTX2sa, and GYM, were detected in oyster samples. DA and homoYTX were not detected in oysters despite of positive detections for both in the phytoplankton concentrates. However, neither the presence nor absence of DA in oysters can be determined because extraction conditions with 100% methanol used to isolate toxins from oysters (recommended by the EU-Harmonised Standard Operating Procedure, 2015) would likely be unsuitable for this water-soluble toxin. In addition, transformation of DA during the digestion process of oysters may also be involved in the negative detections of this toxin. GYM exhibited the highest frequency of positive results in oysters (14/17). OAs were only detected in the hydrolyzed oyster samples. The detection rates of PTX and PTX2sa in oysters were lower than those in the net haul samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Design framework for a spectral mask for a plenoptic camera

    NASA Astrophysics Data System (ADS)

    Berkner, Kathrin; Shroff, Sapna A.

    2012-01-01

    Plenoptic cameras are designed to capture different combinations of light rays from a scene, sampling its lightfield. Such camera designs capturing directional ray information enable applications such as digital refocusing, rotation, or depth estimation. Only few address capturing spectral information of the scene. It has been demonstrated that by modifying a plenoptic camera with a filter array containing different spectral filters inserted in the pupil plane of the main lens, sampling of the spectral dimension of the plenoptic function is performed. As a result, the plenoptic camera is turned into a single-snapshot multispectral imaging system that trades-off spatial with spectral information captured with a single sensor. Little work has been performed so far on analyzing diffraction effects and aberrations of the optical system on the performance of the spectral imager. In this paper we demonstrate simulation of a spectrally-coded plenoptic camera optical system via wave propagation analysis, evaluate quality of the spectral measurements captured at the detector plane, and demonstrate opportunities for optimization of the spectral mask for a few sample applications.

  7. Remaining Sites Verification Package for the 100-F-46, 119-F Stack Sampling French Drain, Waste Site Reclassification Form 2008-021

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. M. Capron

    2008-08-08

    The 100-F-46 french drain consisted of a 1.5 to 3 m long, vertically buried, gravel-filled pipe that was approximately 1 m in diameter. Also included in this waste site was a 5 cm cast-iron pipeline that drained condensate from the 119-F Stack Sampling Building into the 100-F-46 french drain. In accordance with this evaluation, the confirmatory sampling results support a reclassification of this site to No Action. The current site conditions achieve the remedial action objectives and the corresponding remedial action goals established in the Remaining Sites ROD. The results of confirmatory sampling show that residual contaminant concentrations do notmore » preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.« less

  8. Demonstrating the Value of Fine-resolution Optical Data for Minimising Aliasing Impacts on Biogeochemical Models of Surface Waters

    NASA Astrophysics Data System (ADS)

    Chappell, N. A.; Jones, T.; Young, P.; Krishnaswamy, J.

    2015-12-01

    There is increasing awareness that under-sampling may have resulted in the omission of important physicochemical information present in water quality signatures of surface waters - thereby affecting interpretation of biogeochemical processes. For dissolved organic carbon (DOC) and nitrogen this under-sampling can now be avoided using UV-visible spectroscopy measured in-situ and continuously at a fine-resolution e.g. 15 minutes ("real time"). Few methods are available to extract biogeochemical process information directly from such high-frequency data. Jones, Chappell & Tych (2014 Environ Sci Technol: 13289-97) developed one such method using optically-derived DOC data based upon a sophisticated time-series modelling tool. Within this presentation we extend the methodology to quantify the minimum sampling interval required to avoid distortion of model structures and parameters that describe fundamental biogeochemical processes. This shifting of parameters which results from under-sampling is called "aliasing". We demonstrate that storm dynamics at a variety of sites dominate over diurnal and seasonal changes and that these must be characterised by sampling that may be sub-hourly to avoid aliasing. This is considerably shorter than that used by other water quality studies examining aliasing (e.g. Kirchner 2005 Phys Rev: 069902). The modelling approach presented is being developed into a generic tool to calculate the minimum sampling for water quality monitoring in systems driven primarily by hydrology. This is illustrated with fine-resolution, optical data from watersheds in temperate Europe through to the humid tropics.

  9. Paleobiological Implications of the Isotopic Signatures ( 13C, 15N) of Fossil Mammal Collagen in Scladina Cave (Sclayn, Belgium)

    NASA Astrophysics Data System (ADS)

    Bocherens, Hervé; Billiou, Daniel; Patou-Mathis, Marylène; Bonjean, Dominique; Otte, Marcel; Mariotti, André

    1997-11-01

    An isotopic investigation of upper Pleistocene mammal bones and teeth from Scladina cave (Sclayn, Belgium) demonstrated the very good quality of collagen preservation. A preliminary screening of the samples used the amount of nitrogen in whole bone and dentine in order to estimate the preserved amount of collagen before starting the extraction process. The isotopic abundances of fossil specimens from still-extant species are consistent with their trophic position. Moreover, the 15N isotopic abundance is higher in dentine than in bone in bears and hyenas, a phenomenon already observed in modern specimens. These results demonstrate that the isotopic compositions of samples from Scladina cave can be interpreted in ecological terms. Mammoths exhibit a high 15N isotopic abundance relative to other herbivores, as was the case in Siberian and Alaskan samples. These results suggest distinctive dietary adaptations in herbivores living in the mammoth steppe. Cave bears are clearly isotopically different from coeval brown bears, suggesting an ecological separation between species, with a pure vegetarian diet for cave bear and an omnivorous diet for brown bear.

  10. Mycobacterium avium subsp. hominissuis infection in swine associated with peat used for bedding.

    PubMed

    Johansen, Tone Bjordal; Agdestein, Angelika; Lium, Bjørn; Jørgensen, Anne; Djønne, Berit

    2014-01-01

    Mycobacterium avium subsp. hominissuis is an environmental bacterium causing opportunistic infections in swine, resulting in economic losses. Additionally, the zoonotic aspect of such infections is of concern. In the southeastern region of Norway in 2009 and 2010, an increase in condemnation of pig carcasses with tuberculous lesions was seen at the meat inspection. The use of peat as bedding in the herds was suspected to be a common factor, and a project examining pigs and environmental samples from the herds was initiated. Lesions detected at meat inspection in pigs originating from 15 herds were sampled. Environmental samples including peat from six of the herds and from three peat production facilities were additionally collected. Samples were analysed by culture and isolates genotyped by MLVA analysis. Mycobacterium avium subsp. hominissuis was detected in 35 out of 46 pigs, in 16 out of 20 samples of peat, and in one sample of sawdust. MLVA analysis demonstrated identical isolates from peat and pigs within the same farms. Polyclonal infection was demonstrated by analysis of multiple isolates from the same pig. To conclude, the increase in condemnation of porcine carcasses at slaughter due to mycobacteriosis seemed to be related to untreated peat used as bedding.

  11. Mycobacterium avium subsp. hominissuis Infection in Swine Associated with Peat Used for Bedding

    PubMed Central

    Johansen, Tone Bjordal; Lium, Bjørn; Jørgensen, Anne; Djønne, Berit

    2014-01-01

    Mycobacterium avium subsp. hominissuis is an environmental bacterium causing opportunistic infections in swine, resulting in economic losses. Additionally, the zoonotic aspect of such infections is of concern. In the southeastern region of Norway in 2009 and 2010, an increase in condemnation of pig carcasses with tuberculous lesions was seen at the meat inspection. The use of peat as bedding in the herds was suspected to be a common factor, and a project examining pigs and environmental samples from the herds was initiated. Lesions detected at meat inspection in pigs originating from 15 herds were sampled. Environmental samples including peat from six of the herds and from three peat production facilities were additionally collected. Samples were analysed by culture and isolates genotyped by MLVA analysis. Mycobacterium avium subsp. hominissuis was detected in 35 out of 46 pigs, in 16 out of 20 samples of peat, and in one sample of sawdust. MLVA analysis demonstrated identical isolates from peat and pigs within the same farms. Polyclonal infection was demonstrated by analysis of multiple isolates from the same pig. To conclude, the increase in condemnation of porcine carcasses at slaughter due to mycobacteriosis seemed to be related to untreated peat used as bedding. PMID:25431762

  12. Residual Agar Determination in Bacterial Spores by Electrospray Ionization Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wahl, Karen L.; Colburn, Heather A.; Wunschel, David S.

    2010-02-15

    Presented here is an analytical method to detect residual agar from a bacterial spore sample as an indication of culturing on an agar plate. This method is based on the resolubilization of agar polysaccharide from a bacterial spore sample, enzymatic digestion, followed by electrospray ionization tandem mass spectrometry (ESI-MSn) analysis for detection of a specific agar fragment ion. A range of Bacillus species and strains were selected to demonstrate the effectiveness of this approach. The characteristic agar fragment ion was detected in the spores grown on agar that were washed from 1 to 5 times, irradiated or non-irradiated and notmore » in the spores grown in broth. A sample containing approximately 108 spores is currently needed for confident detection of residual agar from culture on agar plates in the presence of bacterial spores with a limit of detection of approximately 1 ppm agar spiked into a broth-grown spore sample. The results of a proficiency test with 42 blinded samples are presented demonstrating the utility of this method with no false positives and only 3 false negatives for samples that were below the detection level of the method as documented.« less

  13. Detecting Renibacterium salmoninarum in wild brown trout by use of multiple organ samples and diagnostic methods

    USGS Publications Warehouse

    Guomundsdottir, S.; Applegate, Lynn M.; Arnason, I.O.; Kristmundsson, A.; Purcell, Maureen K.; Elliott, Diane G.

    2017-01-01

    Renibacterium salmoninarum, the causative agent of salmonid bacterial kidney disease (BKD), is endemic in many wild trout species in northerly regions. The aim of the present study was to determine the optimal R. salmoninarum sampling/testing strategy for wild brown trout (Salmo trutta L.) populations in Iceland. Fish were netted in a lake and multiple organs—kidney, spleen, gills, oesophagus and mid-gut—were sampled and subjected to five detection tests i.e. culture, polyclonal enzyme-linked immunosorbent assay (pELISA) and three different PCR tests. The results showed that each fish had encountered R. salmoninarum but there were marked differences between results obtained depending on organ and test. The bacterium was not cultured from any kidney sample while all kidney samples were positive by pELISA. At least one organ from 92.9% of the fish tested positive by PCR. The results demonstrated that the choice of tissue and diagnostic method can dramatically influence the outcome of R. salmoninarum surveys.

  14. The RBANS Effort Index: Base rates in geriatric samples

    PubMed Central

    Duff, Kevin; Spering, Cynthia C.; O’Bryant, Sid E.; Beglinger, Leigh J.; Moser, David J.; Bayless, John D.; Culp, Kennith R.; Mold, James W.; Adams, Russell L.; Scott, James G.

    2011-01-01

    The Effort Index (EI) of the RBANS was developed to assist clinicians in discriminating patients who demonstrate good effort from those with poor effort. However, there are concerns that older adults might be unfairly penalized by this index, which uses uncorrected raw scores. Using five independent samples of geriatric patients with a broad range of cognitive functioning (e.g., cognitively intact, nursing home residents, probable Alzheimer’s disease), base rates of failure on the EI were calculated. In cognitively intact and mildly impaired samples, few older individuals were classified as demonstrating poor effort (e.g., 3% in cognitively intact). However, in the more severely impaired geriatric patients, over one third had EI scores that fell above suggested cut-off scores (e.g., 37% in nursing home residents, 33% in probable Alzheimer’s disease). In the cognitively intact sample, older and less educated patients were more likely to have scores suggestive of poor effort. Education effects were observed in 3 of the 4 clinical samples. Overall cognitive functioning was significantly correlated with EI scores, with poorer cognition being associated with greater suspicion of low effort. The current results suggest that age, education, and level of cognitive functioning should be taken into consideration when interpreting EI results and that significant caution is warranted when examining EI scores in elders suspected of having dementia. PMID:21390895

  15. Beyond Gorilla and Pongo: alternative models for evaluating variation and sexual dimorphism in fossil hominoid samples.

    PubMed

    Scott, Jeremiah E; Schrein, Caitlin M; Kelley, Jay

    2009-10-01

    Sexual size dimorphism in the postcanine dentition of the late Miocene hominoid Lufengpithecus lufengensis exceeds that in Pongo pygmaeus, demonstrating that the maximum degree of molar size dimorphism in apes is not represented among the extant Hominoidea. It has not been established, however, that the molars of Pongo are more dimorphic than those of any other living primate. In this study, we used resampling-based methods to compare molar dimorphism in Gorilla, Pongo, and Lufengpithecus to that in the papionin Mandrillus leucophaeus to test two hypotheses: (1) Pongo possesses the most size-dimorphic molars among living primates and (2) molar size dimorphism in Lufengpithecus is greater than that in the most dimorphic living primates. Our results show that M. leucophaeus exceeds great apes in its overall level of dimorphism and that L. lufengensis is more dimorphic than the extant species. Using these samples, we also evaluated molar dimorphism and taxonomic composition in two other Miocene ape samples--Ouranopithecus macedoniensis from Greece, specimens of which can be sexed based on associated canines and P(3)s, and the Sivapithecus sample from Haritalyangar, India. Ouranopithecus is more dimorphic than the extant taxa but is similar to Lufengpithecus, demonstrating that the level of molar dimorphism required for the Greek fossil sample under the single-species taxonomy is not unprecedented when the comparative framework is expanded to include extinct primates. In contrast, the Haritalyangar Sivapithecus sample, if itrepresents a single species, exhibits substantially greater molar dimorphism than does Lufengpithecus. Given these results, the taxonomic status of this sample remains equivocal.

  16. Mutagenicity of urine from individuals exposed to LPG combustion products.

    PubMed

    Yin, X J; Liu, J Z; Kong, X H; Chu, J H; Wang, H; Xiao, Z X

    1998-09-01

    The mutagenicity of urine from individuals exposed to the combustion products of liquefied petroleum gas (LPG) was detected with Salmonella typhimurium TA98 and its newly developed derivatives YG1021 (nitroreductase overproducing) and YG1024 (O-acetyltransferase overproducing). The detection showed significantly increased mutagenicity for the two YG strains and increased positive rates for all three strains in the presence of both rat liver S9 and beta-glucuronidase. Further analysis demonstrated that urine samples taken from smoking and non-smoking exposed individuals exhibited significantly higher mutagenic potency (revertants/10 microliters urine concentrate) than their corresponding controls. These results indicate that the increased urine mutagenicity is caused by the exposure to LPG combustion products or smoking. The mutagenic potency of urine samples of all exposed individuals tested with YG1024 was found to be about 7 times higher than with TA98. The difference in mutagenic potency was smaller for the same samples when comparison was made between YG1021 and TA98. This suggests that the mutagenic compounds present in the urine samples contain mainly aromatic compounds as glucuronide conjugates. Our results demonstrate that YG1024 is more sensitive than TA98 in detecting the mutagenicity of these samples. In addition, no significant difference in the mutagenic potency between the 'pure' exposed (non-smokers') and the 'pure' smokers' (unexposed) samples was found in all three tester strains. This might mean that the exposure extent of mutagens/carcinogens in LPG combustion products for exposed individuals roughly corresponds to the smoking level of smokers who smoke 20-40 cigarettes per day. Furthermore, the results also suggest that synergism might exist in the mutagenic effects of exposure to LPG combustion products and cigarette smoking.

  17. A method to estimate the effect of deformable image registration uncertainties on daily dose mapping

    PubMed Central

    Murphy, Martin J.; Salguero, Francisco J.; Siebers, Jeffrey V.; Staub, David; Vaman, Constantin

    2012-01-01

    Purpose: To develop a statistical sampling procedure for spatially-correlated uncertainties in deformable image registration and then use it to demonstrate their effect on daily dose mapping. Methods: Sequential daily CT studies are acquired to map anatomical variations prior to fractionated external beam radiotherapy. The CTs are deformably registered to the planning CT to obtain displacement vector fields (DVFs). The DVFs are used to accumulate the dose delivered each day onto the planning CT. Each DVF has spatially-correlated uncertainties associated with it. Principal components analysis (PCA) is applied to measured DVF error maps to produce decorrelated principal component modes of the errors. The modes are sampled independently and reconstructed to produce synthetic registration error maps. The synthetic error maps are convolved with dose mapped via deformable registration to model the resulting uncertainty in the dose mapping. The results are compared to the dose mapping uncertainty that would result from uncorrelated DVF errors that vary randomly from voxel to voxel. Results: The error sampling method is shown to produce synthetic DVF error maps that are statistically indistinguishable from the observed error maps. Spatially-correlated DVF uncertainties modeled by our procedure produce patterns of dose mapping error that are different from that due to randomly distributed uncertainties. Conclusions: Deformable image registration uncertainties have complex spatial distributions. The authors have developed and tested a method to decorrelate the spatial uncertainties and make statistical samples of highly correlated error maps. The sample error maps can be used to investigate the effect of DVF uncertainties on daily dose mapping via deformable image registration. An initial demonstration of this methodology shows that dose mapping uncertainties can be sensitive to spatial patterns in the DVF uncertainties. PMID:22320766

  18. Performance evaluation of the Aptima® HCV Quant Dx assay for hepatitis C virus (HCV) RNA detection and quantification in comparison to the Abbott RealTime HCV assay.

    PubMed

    Garbuglia, Anna Rosa; Bibbò, Angela; Sciamanna, Roberta; Pisciotta, Marina; Capobianchi, Maria Rosaria

    2017-07-01

    The Aptima HCV Quant Dx assay (Aptima) is a real-time transcription-mediated amplification assay CE-approved for the diagnosis and monitoring of hepatitis C virus (HCV) infection. Aptima's analytical performance was compared to the Abbott RealTime HCV assay (RealTime) in a clinical routine setting. Overall 295 clinical plasma samples (117 prospective/fresh; 178 retrospective/frozen) from HCV-infected patients were tested in Aptima and RealTime to determine concordance on qualitative and quantitative results. Linearity and precision at low viral loads (VLs; 0.8-3.3LogIU/mL) was tested using dilutions of the 5th WHO standard, in 10 and 20 replicates in the two assays, respectively. The ability to measure different HCV genotypes and accuracy were analyzed using the Seracare EQA panel. Inter-assay agreement for qualitative results (prospective samples) was 88% (kappa=0.78). For the 127 samples with quantitative results in both assays, Aptima yielded on average slightly higher values (by 0.24LogIU/mL; Bland-Altman method) than RealTime. Concordance between assay results was excellent (R=0.98). At low VLs (0.8-3.3LogIU/mL), Aptima demonstrated good linearity and precision, similar to RealTime. Aptima detected and accurately quantified all main HCV genotypes. Aptima demonstrated excellent precision, linearity, and accuracy in all genotypes tested. Good concordance was observed between Aptima and RealTime assays in clinical samples. The performance of the Aptima assay, on the fully automated Panther platform, makes it an excellent candidate for the detection and monitoring of HCV RNA in plasma and serum samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Designing MgFe2O4 decorated on green mediated reduced graphene oxide sheets showing photocatalytic performance and luminescence property

    NASA Astrophysics Data System (ADS)

    Shetty, Krushitha; Lokesh, S. V.; Rangappa, Dinesh; Nagaswarupa, H. P.; Nagabhushana, H.; Anantharaju, K. S.; Prashantha, S. C.; Vidya, Y. S.; Sharma, S. C.

    2017-02-01

    Here, a green route has been reported to convert Graphene Oxide (GO) to reduced graphene oxide (RGO) using clove extract. A modest and eco-accommodating sol-gel strategy has been employed to prepare MgFe2O4 nanoparticles, MgFe2O4-RGO nanocomposite samples. The samples were analyzed by Powder X-ray diffraction (PXRD), Fourier Transform Infrared Spectroscopy (FTIR), UV-Visible Spectroscopy, Scanning Electron Microcopy (SEM), Transmission Electron Microscopy (TEM), Photoluminescence (PL) and Electrochemical Impedance Spectroscopy (EIS). PXRD result revealed that the prepared samples were cubic spinel in nature. SEM results uncovered flake like surface morphology of the prepared nanomaterial. Better PL emission signature was observed when excited at 329 nm. PL studies demonstrated that the present samples were potential for the fabrication of white component of white light emitting diodes (WLEDs). Further, MgFe2O4-RGO nanocomposite showed enhanced photocatalytic movement (PCM) and photostability under Sunlight in the decomposition of Malachite Green (MG) compared to MgFe2O4. This can be attributed to the interaction of MgFe2O4 surface with RGO sheets which results in PL quenching, demonstrates that the recombination of photo-induced electrons and holes in MgFe2O4-RGO nanocomposite is more effectively inhibited. A possible mechanism for the enhanced properties of MgFe2O4-RGO nanocomposite was discussed. Moreover, MgFe2O4-RGO photocatalyst also showed easy magnetic separation with high reusability. These results unveil that the synthesized sample can be used in display applications and also as a potential photocatalyst.

  20. Estimating the uncertainty from sampling in pollution crime investigation: The importance of metrology in the forensic interpretation of environmental data.

    PubMed

    Barazzetti Barbieri, Cristina; de Souza Sarkis, Jorge Eduardo

    2018-07-01

    The forensic interpretation of environmental analytical data is usually challenging due to the high geospatial variability of these data. The measurements' uncertainty includes contributions from the sampling and from the sample handling and preparation processes. These contributions are often disregarded in analytical techniques results' quality assurance. A pollution crime investigation case was used to carry out a methodology able to address these uncertainties in two different environmental compartments, freshwater sediments and landfill leachate. The methodology used to estimate the uncertainty was the duplicate method (that replicates predefined steps of the measurement procedure in order to assess its precision) and the parameters used to investigate the pollution were metals (Cr, Cu, Ni, and Zn) in the leachate, the suspect source, and in the sediment, the possible sink. The metal analysis results were compared to statutory limits and it was demonstrated that Cr and Ni concentrations in sediment samples exceeded the threshold levels at all sites downstream the pollution sources, considering the expanded uncertainty U of the measurements and a probability of contamination >0.975, at most sites. Cu and Zn concentrations were above the statutory limits at two sites, but the classification was inconclusive considering the uncertainties of the measurements. Metal analyses in leachate revealed that Cr concentrations were above the statutory limits with a probability of contamination >0.975 in all leachate ponds while the Cu, Ni and Zn probability of contamination was below 0.025. The results demonstrated that the estimation of the sampling uncertainty, which was the dominant component of the combined uncertainty, is required for a comprehensive interpretation of the environmental analyses results, particularly in forensic cases. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Critical points of DNA quantification by real-time PCR – effects of DNA extraction method and sample matrix on quantification of genetically modified organisms

    PubMed Central

    Cankar, Katarina; Štebih, Dejan; Dreo, Tanja; Žel, Jana; Gruden, Kristina

    2006-01-01

    Background Real-time PCR is the technique of choice for nucleic acid quantification. In the field of detection of genetically modified organisms (GMOs) quantification of biotech products may be required to fulfil legislative requirements. However, successful quantification depends crucially on the quality of the sample DNA analyzed. Methods for GMO detection are generally validated on certified reference materials that are in the form of powdered grain material, while detection in routine laboratories must be performed on a wide variety of sample matrixes. Due to food processing, the DNA in sample matrixes can be present in low amounts and also degraded. In addition, molecules of plant origin or from other sources that affect PCR amplification of samples will influence the reliability of the quantification. Further, the wide variety of sample matrixes presents a challenge for detection laboratories. The extraction method must ensure high yield and quality of the DNA obtained and must be carefully selected, since even components of DNA extraction solutions can influence PCR reactions. GMO quantification is based on a standard curve, therefore similarity of PCR efficiency for the sample and standard reference material is a prerequisite for exact quantification. Little information on the performance of real-time PCR on samples of different matrixes is available. Results Five commonly used DNA extraction techniques were compared and their suitability for quantitative analysis was assessed. The effect of sample matrix on nucleic acid quantification was assessed by comparing 4 maize and 4 soybean matrixes. In addition 205 maize and soybean samples from routine analysis were analyzed for PCR efficiency to assess variability of PCR performance within each sample matrix. Together with the amount of DNA needed for reliable quantification, PCR efficiency is the crucial parameter determining the reliability of quantitative results, therefore it was chosen as the primary criterion by which to evaluate the quality and performance on different matrixes and extraction techniques. The effect of PCR efficiency on the resulting GMO content is demonstrated. Conclusion The crucial influence of extraction technique and sample matrix properties on the results of GMO quantification is demonstrated. Appropriate extraction techniques for each matrix need to be determined to achieve accurate DNA quantification. Nevertheless, as it is shown that in the area of food and feed testing matrix with certain specificities is impossible to define strict quality controls need to be introduced to monitor PCR. The results of our study are also applicable to other fields of quantitative testing by real-time PCR. PMID:16907967

  2. Information engineering for molecular diagnostics.

    PubMed Central

    Sorace, J. M.; Ritondo, M.; Canfield, K.

    1994-01-01

    Clinical laboratories are beginning to apply the recent advances in molecular biology to the testing of patient samples. The emerging field of Molecular Diagnostics will require a new Molecular Diagnostics Laboratory Information System which handles the data types, samples and test methods found in this field. The system must be very flexible in regards to supporting ad-hoc queries. The requirements which are shaping the developments in this field are reviewed and a data model developed. Several queries which demonstrate the data models ability to support the information needs of this area have been developed and run. These results demonstrate the ability of the purposed data model to meet the current and projected needs of this rapidly expanding field. PMID:7949937

  3. Factor complexity of crash occurrence: An empirical demonstration using boosted regression trees.

    PubMed

    Chung, Yi-Shih

    2013-12-01

    Factor complexity is a characteristic of traffic crashes. This paper proposes a novel method, namely boosted regression trees (BRT), to investigate the complex and nonlinear relationships in high-variance traffic crash data. The Taiwanese 2004-2005 single-vehicle motorcycle crash data are used to demonstrate the utility of BRT. Traditional logistic regression and classification and regression tree (CART) models are also used to compare their estimation results and external validities. Both the in-sample cross-validation and out-of-sample validation results show that an increase in tree complexity provides improved, although declining, classification performance, indicating a limited factor complexity of single-vehicle motorcycle crashes. The effects of crucial variables including geographical, time, and sociodemographic factors explain some fatal crashes. Relatively unique fatal crashes are better approximated by interactive terms, especially combinations of behavioral factors. BRT models generally provide improved transferability than conventional logistic regression and CART models. This study also discusses the implications of the results for devising safety policies. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Ex vivo validation of photo-magnetic imaging.

    PubMed

    Luk, Alex; Nouizi, Farouk; Erkol, Hakan; Unlu, Mehmet B; Gulsen, Gultekin

    2017-10-15

    We recently introduced a new high-resolution diffuse optical imaging technique termed photo-magnetic imaging (PMI), which utilizes magnetic resonance thermometry (MRT) to monitor the 3D temperature distribution induced in a medium illuminated with a near-infrared light. The spatiotemporal temperature distribution due to light absorption can be accurately estimated using a combined photon propagation and heat diffusion model. High-resolution optical absorption images are then obtained by iteratively minimizing the error between the measured and modeled temperature distributions. We have previously demonstrated the feasibility of PMI with experimental studies using tissue simulating agarose phantoms. In this Letter, we present the preliminary ex vivo PMI results obtained with a chicken breast sample. Similarly to the results obtained on phantoms, the reconstructed images reveal that PMI can quantitatively resolve an inclusion with a 3 mm diameter embedded deep in a biological tissue sample with only 10% error. These encouraging results demonstrate the high performance of PMI in ex vivo biological tissue and its potential for in vivo imaging.

  5. Sampling scales define occupancy and underlying occupancy-abundance relationships in animals.

    PubMed

    Steenweg, Robin; Hebblewhite, Mark; Whittington, Jesse; Lukacs, Paul; McKelvey, Kevin

    2018-01-01

    Occupancy-abundance (OA) relationships are a foundational ecological phenomenon and field of study, and occupancy models are increasingly used to track population trends and understand ecological interactions. However, these two fields of ecological inquiry remain largely isolated, despite growing appreciation of the importance of integration. For example, using occupancy models to infer trends in abundance is predicated on positive OA relationships. Many occupancy studies collect data that violate geographical closure assumptions due to the choice of sampling scales and application to mobile organisms, which may change how occupancy and abundance are related. Little research, however, has explored how different occupancy sampling designs affect OA relationships. We develop a conceptual framework for understanding how sampling scales affect the definition of occupancy for mobile organisms, which drives OA relationships. We explore how spatial and temporal sampling scales, and the choice of sampling unit (areal vs. point sampling), affect OA relationships. We develop predictions using simulations, and test them using empirical occupancy data from remote cameras on 11 medium-large mammals. Surprisingly, our simulations demonstrate that when using point sampling, OA relationships are unaffected by spatial sampling grain (i.e., cell size). In contrast, when using areal sampling (e.g., species atlas data), OA relationships are affected by spatial grain. Furthermore, OA relationships are also affected by temporal sampling scales, where the curvature of the OA relationship increases with temporal sampling duration. Our empirical results support these predictions, showing that at any given abundance, the spatial grain of point sampling does not affect occupancy estimates, but longer surveys do increase occupancy estimates. For rare species (low occupancy), estimates of occupancy will quickly increase with longer surveys, even while abundance remains constant. Our results also clearly demonstrate that occupancy for mobile species without geographical closure is not true occupancy. The independence of occupancy estimates from spatial sampling grain depends on the sampling unit. Point-sampling surveys can, however, provide unbiased estimates of occupancy for multiple species simultaneously, irrespective of home-range size. The use of occupancy for trend monitoring needs to explicitly articulate how the chosen sampling scales define occupancy and affect the occupancy-abundance relationship. © 2017 by the Ecological Society of America.

  6. Soft Robotic Grippers for Biological Sampling on Deep Reefs.

    PubMed

    Galloway, Kevin C; Becker, Kaitlyn P; Phillips, Brennan; Kirby, Jordan; Licht, Stephen; Tchernov, Dan; Wood, Robert J; Gruber, David F

    2016-03-01

    This article presents the development of an underwater gripper that utilizes soft robotics technology to delicately manipulate and sample fragile species on the deep reef. Existing solutions for deep sea robotic manipulation have historically been driven by the oil industry, resulting in destructive interactions with undersea life. Soft material robotics relies on compliant materials that are inherently impedance matched to natural environments and to soft or fragile organisms. We demonstrate design principles for soft robot end effectors, bench-top characterization of their grasping performance, and conclude by describing in situ testing at mesophotic depths. The result is the first use of soft robotics in the deep sea for the nondestructive sampling of benthic fauna.

  7. Microwave absorption properties of gold nanoparticle doped polymers

    NASA Astrophysics Data System (ADS)

    Jiang, C.; Ouattara, L.; Ingrosso, C.; Curri, M. L.; Krozer, V.; Boisen, A.; Jakobsen, M. H.; Johansen, T. K.

    2011-03-01

    This paper presents a method for characterizing microwave absorption properties of gold nanoparticle doped polymers. The method is based on on-wafer measurements at the frequencies from 0.5 GHz to 20 GHz. The on-wafer measurement method makes it possible to characterize electromagnetic (EM) property of small volume samples. The epoxy based SU8 polymer and SU8 doped with gold nanoparticles are chosen as the samples under test. Two types of microwave test devices are designed for exciting the samples through electrical coupling and magnetic coupling, respectively. Measurement results demonstrate that the nanocomposites absorb a certain amount of microwave energy due to gold nanoparticles. Higher nanoparticle concentration results in more significant absorption effect.

  8. Soft Robotic Grippers for Biological Sampling on Deep Reefs

    PubMed Central

    Galloway, Kevin C.; Becker, Kaitlyn P.; Phillips, Brennan; Kirby, Jordan; Licht, Stephen; Tchernov, Dan; Gruber, David F.

    2016-01-01

    Abstract This article presents the development of an underwater gripper that utilizes soft robotics technology to delicately manipulate and sample fragile species on the deep reef. Existing solutions for deep sea robotic manipulation have historically been driven by the oil industry, resulting in destructive interactions with undersea life. Soft material robotics relies on compliant materials that are inherently impedance matched to natural environments and to soft or fragile organisms. We demonstrate design principles for soft robot end effectors, bench-top characterization of their grasping performance, and conclude by describing in situ testing at mesophotic depths. The result is the first use of soft robotics in the deep sea for the nondestructive sampling of benthic fauna. PMID:27625917

  9. Evaluation of the Biological Sampling Kit (BiSKit) for Large-Area Surface Sampling

    PubMed Central

    Buttner, Mark P.; Cruz, Patricia; Stetzenbach, Linda D.; Klima-Comba, Amy K.; Stevens, Vanessa L.; Emanuel, Peter A.

    2004-01-01

    Current surface sampling methods for microbial contaminants are designed to sample small areas and utilize culture analysis. The total number of microbes recovered is low because a small area is sampled, making detection of a potential pathogen more difficult. Furthermore, sampling of small areas requires a greater number of samples to be collected, which delays the reporting of results, taxes laboratory resources and staffing, and increases analysis costs. A new biological surface sampling method, the Biological Sampling Kit (BiSKit), designed to sample large areas and to be compatible with testing with a variety of technologies, including PCR and immunoassay, was evaluated and compared to other surface sampling strategies. In experimental room trials, wood laminate and metal surfaces were contaminated by aerosolization of Bacillus atrophaeus spores, a simulant for Bacillus anthracis, into the room, followed by settling of the spores onto the test surfaces. The surfaces were sampled with the BiSKit, a cotton-based swab, and a foam-based swab. Samples were analyzed by culturing, quantitative PCR, and immunological assays. The results showed that the large surface area (1 m2) sampled with the BiSKit resulted in concentrations of B. atrophaeus in samples that were up to 10-fold higher than the concentrations obtained with the other methods tested. A comparison of wet and dry sampling with the BiSKit indicated that dry sampling was more efficient (efficiency, 18.4%) than wet sampling (efficiency, 11.3%). The sensitivities of detection of B. atrophaeus on metal surfaces were 42 ± 5.8 CFU/m2 for wet sampling and 100.5 ± 10.2 CFU/m2 for dry sampling. These results demonstrate that the use of a sampling device capable of sampling larger areas results in higher sensitivity than that obtained with currently available methods and has the advantage of sampling larger areas, thus requiring collection of fewer samples per site. PMID:15574898

  10. Psychometric Assessment of the Chinese Version of the Supportive Care Needs Survey Short-Form (SCNS-SF34-C) among Hong Kong and Taiwanese Chinese Colorectal Cancer Patients

    PubMed Central

    Li, Wylie Wai Yee; Lam, Wendy Wing Tak; Shun, Shiow-Ching; Lai, Yeur-Hur; Law, Wai-Lun; Poon, Jensen; Fielding, Richard

    2013-01-01

    Background Accurate assessment of unmet supportive care needs is essential for optimal cancer patient care. This study used confirmatory factor analysis (CFA) to test the known factor structures of the short form of Supportive Care Need Survey (SCNS-34) in Hong Kong and Taiwan Chinese patients diagnosed with colorectal cancer (CRC). Methods 360 Hong Kong and 263 Taiwanese Chinese CRC patients completed the Chinese version of SCNS-SF34. Comparative measures (patient satisfaction, anxiety, depression, and symptom distress) tested convergent validity while known group differences were examined to test discriminant validity. Results The original 5-factor and recent 4-factor models of the SCNS demonstrated poor data fit using CFA in both Hong Kong and Taiwan samples. Subsequently a modified five-factor model with correlated residuals demonstrated acceptable fit in both samples. Correlations demonstrated convergent and divergent validity and known group differences were observed. Conclusions While the five-factor model demonstrated a better fit for data from Chinese colorectal cancer patients, some of the items within its domain overlapped, suggesting item redundancy. The five-factor model showed good psychometric properties in these samples but also suggests conceptualization of unmet supportive care needs are currently inadequate. PMID:24146774

  11. Tank 241-AX-104 upper vadose zone cone penetrometer demonstration sampling and analysis plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    FIELD, J.G.

    1999-02-02

    This sampling and analysis plan (SAP) is the primary document describing field and laboratory activities and requirements for the tank 241-AX-104 upper vadose zone cone penetrometer (CP) demonstration. It is written in accordance with Hanford Tank Initiative Tank 241-AX-104 Upper Vadose Zone Demonstration Data Quality Objective (Banning 1999). This technology demonstration, to be conducted at tank 241-AX-104, is being performed by the Hanford Tanks Initiative (HTI) Project as a part of Tank Waste Remediation System (TWRS) Retrieval Program (EM-30) and the Office of Science and Technology (EM-50) Tanks Focus Area. Sample results obtained as part of this demonstration will providemore » additional information for subsequent revisions to the Retrieval Performance Evaluation (RPE) report (Jacobs 1998). The RPE Report is the result of an evaluation of a single tank farm (AX Tank Farm) used as the basis for demonstrating a methodology for developing the data and analyses necessary to support making tank waste retrieval decisions within the context of tank farm closure requirements. The RPE includes a study of vadose zone contaminant transport mechanisms, including analysis of projected tank leak characteristics, hydrogeologic characteristics of tank farm soils, and the observed distribution of contaminants in the vadose zone in the tank farms. With limited characterization information available, large uncertainties exist as to the nature and extent of contaminants that may exist in the upper vadose zone in the AX Tank Farm. Traditionally, data has been collected from soils in the vadose zone through the installation of boreholes and wells. Soil samples are collected as the bore hole is advanced and samples are screened on site and/or sent to a laboratory for analysis. Some in-situ geophysical methods of contaminant analysis can be used to evaluate radionuclide levels in the soils adjacent to an existing borehole. However, geophysical methods require compensation for well casing interference and soil moisture content and may not be successful in some conditions. In some cases the level of interference must be estimated due to uncertainties regarding the materials used in well construction and soil conditions, Well casing deployment used for many in-situ geophysical methods is relatively expensive and geophysical methods do not generally provide real time values for contaminants. In addition, some of these methods are not practical within the boundaries of the tank farm due to physical constraints, such as underground piping and other hardware. The CP technologies could facilitate future characterization of vadose zone soils by providing vadose zone data in near real-time, reducing the number of soil samples and boreholes required, and reducing characterization costs.« less

  12. Applicability of a novel immunoassay based on surface plasmon resonance for the diagnosis of Chagas disease.

    PubMed

    Luz, João G G; Souto, Dênio E P; Machado-Assis, Girley F; de Lana, Marta; Luz, Rita C S; Martins-Filho, Olindo A; Damos, Flávio S; Martins, Helen R

    2016-02-15

    We defined the methodological criteria for the interpretation of the results provided by a novel immunoassay based on surface plasmon resonance (SPR) to detect antibodies anti-Trypanosoma cruzi in human sera (SPRCruzi). Then, we evaluated its applicability as a diagnostic tool for Chagas disease. To define the cut-off point and serum dilution factor, 57 samples were analyzed at SPRCruzi and the obtained values of SPR angle displacement (ΔθSPR) were submitted to statistical analysis. Adopting the indicated criteria, its performance was evaluated into a wide panel of samples, being 99 Chagas disease patients, 30 non-infected subjects and 42 with other parasitic/infectious diseases. In parallel, these samples were also analyzed by ELISA. Our data demonstrated that 1:320 dilution and cut-off point at ∆θSPR=17.2 m° provided the best results. Global performance analysis demonstrated satisfactory sensitivity (100%), specificity (97.2%), positive predictive value (98%), negative predictive value (100%) and global accuracy (99.6%). ELISA and SPRCruzi showed almost perfect agreement, mainly between chagasic and non-infected individuals. However, the new immunoassay was better in discriminate Chagas disease from other diseases. This work demonstrated the applicability of SPRCruzi as a feasible, real time, label free, sensible and specific methodology for the diagnosis of Chagas disease. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Comparison of droplet digital PCR and conventional quantitative PCR for measuring EGFR gene mutation

    PubMed Central

    ZHANG, BO; XU, CHUN-WEI; SHAO, YUN; WANG, HUAI-TAO; WU, YONG-FANG; SONG, YE-YING; LI, XIAO-BING; ZHANG, ZHE; WANG, WEN-JING; LI, LI-QIONG; CAI, CONG-LI

    2015-01-01

    Early detection of epidermal growth factor receptor (EGFR) mutation, particularly EGFR T790M mutation, is of clinical significance. The aim of the present study was to compare the performances of amplification refractory mutation system-based quantitative polymerase chain reaction (ARMS-qPCR) and droplet digital polymerase chain reaction (ddPCR) approaches in the detection of EGFR mutation and explore the feasibility of using ddPCR in the detection of samples with low mutation rates. EGFR gene mutations in plasmid samples with different T790M mutation rates (0.1–5%) and 10 clinical samples were detected using the ARMS-qPCR and ddPCR approaches. The results demonstrated that the ARMS-qPCR method stably detected the plasmid samples (6,000 copies) with 5 and 1% mutation rates, while the ddPCR approach reliably detected those with 5% (398 copies), 1% (57 copies), 0.5% (24 copies) and 0.1% (average 6 copies) mutation rates. For the 10 clinical samples, the results for nine samples by the ARMS-qPCR and ddPCR methods were consistent; however, the sample N006, indicated to be EGFR wild-type by ARMS-qPCR, was revealed to have a clear EGFR T790M mutation with seven copies of mutant alleles in a background of 6,000 wild-type copies using ddPCR technology. This study demonstrates the feasibility of applying the ddPCR system to detect EGFR mutation and identified the advantage of ddPCR in the detection of samples with a low EGFR mutation abundance, particularly the secondary EGFR T790M resistance mutation, which enables early diagnosis before acquired resistance to tyrosine kinase inhibitors becomes clinically detectable. PMID:25780439

  14. Time-Lapse Electrical Geophysical Monitoring of Amendment-Based Biostimulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Timothy C.; Versteeg, Roelof; Day-Lewis, Frederick D.

    Biostimulation is increasingly used to accelerate microbial remediation of recalcitrant groundwater contaminants. Effective application of biostimulation requires successful emplacement of amendment in the contaminant target zone. Verification of remediation performance requires postemplacement assessment and contaminant monitoring. Sampling based approaches are expensive and provide low-density spatial and temporal information. Time-lapse electrical resistivity tomography (ERT) is an effective geophysical method for determining temporal changes in subsurface electrical conductivity. Because remedial amendments and biostimulation-related biogeochemical processes often change subsurface electrical conductivity, ERT can complement and enhance sampling-based approaches for assessing emplacement and monitoring biostimulation-based remediation. Field studies demonstrating the ability of time-lapse ERTmore » to monitor amendment emplacement and behavior were performed during a biostimulation remediation effort conducted at the Department of Defense Reutilization and Marketing Office (DRMO) Yard, in Brandywine, Maryland, United States. Geochemical fluid sampling was used to calibrate a petrophysical relation in order to predict groundwater indicators of amendment distribution. The petrophysical relations were field validated by comparing predictions to sequestered fluid sample results, thus demonstrating the potential of electrical geophysics for quantitative assessment of amendment-related geochemical properties. Crosshole radar zero-offset profile and borehole geophysical logging were also performed to augment the data set and validate interpretation. In addition to delineating amendment transport in the first 10 months after emplacement, the time-lapse ERT results show later changes in bulk electrical properties interpreted as mineral precipitation. Results support the use of more cost-effective surfacebased ERT in conjunction with limited field sampling to improve spatial and temporal monitoring of amendment emplacement and remediation performance.« less

  15. Time-lapse electrical geophysical monitoring of amendment-based biostimulation

    USGS Publications Warehouse

    Johnson, Timothy C.; Versteeg, Roelof J.; Day-Lewis, Frederick D.; Major, William; Lane, John W.

    2015-01-01

    Biostimulation is increasingly used to accelerate microbial remediation of recalcitrant groundwater contaminants. Effective application of biostimulation requires successful emplacement of amendment in the contaminant target zone. Verification of remediation performance requires postemplacement assessment and contaminant monitoring. Sampling-based approaches are expensive and provide low-density spatial and temporal information. Time-lapse electrical resistivity tomography (ERT) is an effective geophysical method for determining temporal changes in subsurface electrical conductivity. Because remedial amendments and biostimulation-related biogeochemical processes often change subsurface electrical conductivity, ERT can complement and enhance sampling-based approaches for assessing emplacement and monitoring biostimulation-based remediation.Field studies demonstrating the ability of time-lapse ERT to monitor amendment emplacement and behavior were performed during a biostimulation remediation effort conducted at the Department of Defense Reutilization and Marketing Office (DRMO) Yard, in Brandywine, Maryland, United States. Geochemical fluid sampling was used to calibrate a petrophysical relation in order to predict groundwater indicators of amendment distribution. The petrophysical relations were field validated by comparing predictions to sequestered fluid sample results, thus demonstrating the potential of electrical geophysics for quantitative assessment of amendment-related geochemical properties. Crosshole radar zero-offset profile and borehole geophysical logging were also performed to augment the data set and validate interpretation.In addition to delineating amendment transport in the first 10 months after emplacement, the time-lapse ERT results show later changes in bulk electrical properties interpreted as mineral precipitation. Results support the use of more cost-effective surface-based ERT in conjunction with limited field sampling to improve spatial and temporal monitoring of amendment emplacement and remediation performance.

  16. How-To-Do-It: Measuring Vegetation Biomass and Production.

    ERIC Educational Resources Information Center

    Collins, Don; Weaver, T.

    1988-01-01

    Describes a lab exercise used to demonstrate the measurement of biomass in a three layered forest. Discusses sampling, estimation methods, and the analysis of results. Presents an example of a summary sheet for this activity. (CW)

  17. Instant, Visual, and Instrument-Free Method for On-Site Screening of GTS 40-3-2 Soybean Based on Body-Heat Triggered Recombinase Polymerase Amplification.

    PubMed

    Wang, Rui; Zhang, Fang; Wang, Liu; Qian, Wenjuan; Qian, Cheng; Wu, Jian; Ying, Yibin

    2017-04-18

    On-site monitoring the plantation of genetically modified (GM) crops is of critical importance in agriculture industry throughout the world. In this paper, a simple, visual and instrument-free method for instant on-site detection of GTS 40-3-2 soybean has been developed. It is based on body-heat recombinase polymerase amplification (RPA) and followed with naked-eye detection via fluorescent DNA dye. Combining with extremely simplified sample preparation, the whole detection process can be accomplished within 10 min and the fluorescent results can be photographed by an accompanied smart phone. Results demonstrated a 100% detection rate for screening of practical GTS 40-3-2 soybean samples by 20 volunteers under different ambient temperatures. This method is not only suitable for on-site detection of GM crops but also demonstrates great potential to be applied in other fields.

  18. Polymer platforms for selective detection of cocaine in street samples adulterated with levamisole.

    PubMed

    Florea, Anca; Cowen, Todd; Piletsky, Sergey; De Wael, Karolien

    2018-08-15

    Accurate drug detection is of utmost importance for fighting against drug abuse. With a high number of cutting agents and adulterants being added to cut or mask drugs in street powders the number of false results is increasing. We demonstrate for the first time the usefulness of employing polymers readily synthesized by electrodeposition to selectively detect cocaine in the presence of the commonly used adulterant levamisole. The polymers were selected by computational modelling to exhibit high binding affinity towards cocaine and deposited directly on the surface of graphene-modified electrodes via electropolymerization. The resulting platforms allowed a distinct electrochemical signal for cocaine, which is otherwise suppressed by levamisole. Square wave voltammetry was used to quantify cocaine alone and in the presence of levamisole. The usefulness of the platforms was demonstrated in the screening of real street samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Influence of ECG sampling rate in fetal heart rate variability analysis.

    PubMed

    De Jonckheere, J; Garabedian, C; Charlier, P; Champion, C; Servan-Schreiber, E; Storme, L; Debarge, V; Jeanne, M; Logier, R

    2017-07-01

    Fetal hypoxia results in a fetal blood acidosis (pH<;7.10). In such a situation, the fetus develops several adaptation mechanisms regulated by the autonomic nervous system. Many studies demonstrated significant changes in heart rate variability in hypoxic fetuses. So, fetal heart rate variability analysis could be of precious help for fetal hypoxia prediction. Commonly used fetal heart rate variability analysis methods have been shown to be sensitive to the ECG signal sampling rate. Indeed, a low sampling rate could induce variability in the heart beat detection which will alter the heart rate variability estimation. In this paper, we introduce an original fetal heart rate variability analysis method. We hypothesize that this method will be less sensitive to ECG sampling frequency changes than common heart rate variability analysis methods. We then compared the results of this new heart rate variability analysis method with two different sampling frequencies (250-1000 Hz).

  20. Evidence against the temporal subsampling account of illusory motion reversal

    PubMed Central

    Kline, Keith A.; Eagleman, David M.

    2010-01-01

    An illusion of reversed motion may occur sporadically while viewing continuous smooth motion. This has been suggested as evidence of discrete temporal sampling by the visual system in analogy to the sampling that generates the wagon–wheel effect on film. In an alternative theory, the illusion is not the result of discrete sampling but instead of perceptual rivalry between appropriately activated and spuriously activated motion detectors. Results of the current study demonstrate that illusory reversals of two spatially overlapping and orthogonal motions often occur separately, providing evidence against the possibility that illusory motion reversal (IMR) is caused by temporal sampling within a visual region. Further, we find that IMR occurs with non-uniform and non-periodic stimuli—an observation that is not accounted for by the temporal sampling hypothesis. We propose, that a motion aftereffect is superimposed on the moving stimulus, sporadically allowing motion detectors for the reverse direction to dominate perception. PMID:18484852

  1. Using machine learning to accelerate sampling-based inversion

    NASA Astrophysics Data System (ADS)

    Valentine, A. P.; Sambridge, M.

    2017-12-01

    In most cases, a complete solution to a geophysical inverse problem (including robust understanding of the uncertainties associated with the result) requires a sampling-based approach. However, the computational burden is high, and proves intractable for many problems of interest. There is therefore considerable value in developing techniques that can accelerate sampling procedures.The main computational cost lies in evaluation of the forward operator (e.g. calculation of synthetic seismograms) for each candidate model. Modern machine learning techniques-such as Gaussian Processes-offer a route for constructing a computationally-cheap approximation to this calculation, which can replace the accurate solution during sampling. Importantly, the accuracy of the approximation can be refined as inversion proceeds, to ensure high-quality results.In this presentation, we describe and demonstrate this approach-which can be seen as an extension of popular current methods, such as the Neighbourhood Algorithm, and bridges the gap between prior- and posterior-sampling frameworks.

  2. High Accuracy Evaluation of the Finite Fourier Transform Using Sampled Data

    NASA Technical Reports Server (NTRS)

    Morelli, Eugene A.

    1997-01-01

    Many system identification and signal processing procedures can be done advantageously in the frequency domain. A required preliminary step for this approach is the transformation of sampled time domain data into the frequency domain. The analytical tool used for this transformation is the finite Fourier transform. Inaccuracy in the transformation can degrade system identification and signal processing results. This work presents a method for evaluating the finite Fourier transform using cubic interpolation of sampled time domain data for high accuracy, and the chirp Zeta-transform for arbitrary frequency resolution. The accuracy of the technique is demonstrated in example cases where the transformation can be evaluated analytically. Arbitrary frequency resolution is shown to be important for capturing details of the data in the frequency domain. The technique is demonstrated using flight test data from a longitudinal maneuver of the F-18 High Alpha Research Vehicle.

  3. The zymographic evaluation of gelatinase (MMP-2 and -9) levels in acute and chronic periapical abscesses.

    PubMed

    Buzoglu, Hatice Dogan; Unal, Hasan; Ulger, Celal; Mert, Safak; Kücükyildirim, Sibel; Er, Nuray

    2009-11-01

    This study investigated the presence and levels of matrix metalloproteinases (MMP)-2 and -9 in periapical abscesses. Eighteen samples of intracanal exudates containing pus were collected from teeth with clinically and radiographically verified primary or secondary acute and chronic apical abscesses. Pro- and active forms of MMP-2 and MMP-9 levels were analyzed by using substrate gel zymography followed by an image analysis system. Statistical analysis was performed using the Kruskall-Wallis and Mann-Whitney U tests with Bonferroni adjustment. Both forms of MMP-9 were detected in all pus samples and demonstrated marked differences among the experimental groups (P < .05). Primary or secondary acute apical abscess samples demonstrated significantly higher MMP-9 levels compared with MMP-2 levels (P < .01). However, MMP-2 could not be detected in chronic apical abscesses. According to the results of this study, gelatinases might affect the pathogenesis of acute and chronic periapical abscesses.

  4. Methylobacterium spp. as an indicator for the presence or absence of Mycobacterium spp.

    PubMed

    Falkinham, Joseph O; Williams, Myra D; Kwait, Rebecca; Lande, Leah

    2016-06-01

    A published survey of bacteria in showerhead biofilm samples revealed that Methylobacterium spp. and Mycobacterium spp. seldom coexisted in biofilms. To confirm that information, biofilm samples were collected from household plumbing of Mycobacterium avium patients and Methylobacterium spp. and M. avium numbers were measured by direct colony counts. The results demonstrated that if Methylobacterium spp. were present, Mycobacterium spp. were absent, and the opposite. The data demonstrate that microbial populations in biofilms can influence the presence or absence of opportunistic premise plumbing pathogens and, thereby, increase the range of strategies to reduce exposure to waterborne pathogens. Finally, by assessing for the visual presence of methylobacteria as pink pigmentation on showers and shower curtains, homeowners and managers of hospitals and other buildings can quickly determine whether a premise plumbing biofilm sample has mycobacteria with a high degree of assurance. Copyright © 2016 Asian African Society for Mycobacteriology. Published by Elsevier Ltd. All rights reserved.

  5. Children's Attributional Style from Middle Childhood to Early Adolescence: Further Validation of the Paper-and-Pencil Versions of the Children's Attributional Style Interview

    ERIC Educational Resources Information Center

    Rueger, Sandra Yu; Haines, Beth A.; Malecki, Christine Kerres

    2010-01-01

    The psychometric properties of two paper-and-pencil versions of the Children's Attributional Style Interview (i.e., CASI-I and CASI-II) were evaluated in a sample of 166 third and fourth graders and a sample of 245 sixth and seventh graders. The results demonstrated strong internal consistency reliability, convergent validity, and a factor…

  6. Host specificity and coevolution of Flavobacteriaceae endosymbionts within the siphonous green seaweed Bryopsis.

    PubMed

    Hollants, Joke; Leliaert, Frederik; Verbruggen, Heroen; De Clerck, Olivier; Willems, Anne

    2013-06-01

    The siphonous green seaweed Bryopsis harbors complex intracellular bacterial communities. Previous studies demonstrated that certain species form close, obligate associations with Flavobacteriaceae. A predominant imprint of host evolutionary history on the presence of these bacteria suggests a highly specialized association. In this study we elaborate on previous results by expanding the taxon sampling and testing for host-symbiont coevolution Therefore, we optimized a PCR protocol to directly and specifically amplify Flavobacteriaceae endosymbiont 16S rRNA gene sequences, which allowed us to screen a large number of algal samples without the need for cultivation or surface sterilization. We analyzed 146 Bryopsis samples, and 92 additional samples belonging to the Bryopsidales and other orders within the class Ulvophyceae. Results indicate that the Flavobacteriaceae endosymbionts are restricted to Bryopsis, and only occur within specific, warm-temperate and tropical clades of the genus. Statistical analyses (AMOVA) demonstrate a significant non-random host-symbiont association. Comparison of bacterial 16S rRNA and Bryopsis rbcL phylogenies, however, reveal complex host-symbiont evolutionary associations, whereby closely related hosts predominantly harbor genetically similar endosymbionts. Bacterial genotypes are rarely confined to a single Bryopsis species and most Bryopsis species harbored several Flavobacteriaceae, obscuring a clear pattern of coevolution. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Ultratrace level determination and quantitative analysis of kidney injury biomarkers in patient samples attained by zinc oxide nanorods

    NASA Astrophysics Data System (ADS)

    Singh, Manpreet; Alabanza, Anginelle; Gonzalez, Lorelis E.; Wang, Weiwei; Reeves, W. Brian; Hahm, Jong-In

    2016-02-01

    Determining ultratrace amounts of protein biomarkers in patient samples in a straightforward and quantitative manner is extremely important for early disease diagnosis and treatment. Here, we successfully demonstrate the novel use of zinc oxide nanorods (ZnO NRs) in the ultrasensitive and quantitative detection of two acute kidney injury (AKI)-related protein biomarkers, tumor necrosis factor (TNF)-α and interleukin (IL)-8, directly from patient samples. We first validate the ZnO NRs-based IL-8 results via comparison with those obtained from using a conventional enzyme-linked immunosorbent method in samples from 38 individuals. We further assess the full detection capability of the ZnO NRs-based technique by quantifying TNF-α, whose levels in human urine are often below the detection limits of conventional methods. Using the ZnO NR platforms, we determine the TNF-α concentrations of all 46 patient samples tested, down to the fg per mL level. Subsequently, we screen for TNF-α levels in approximately 50 additional samples collected from different patient groups in order to demonstrate a potential use of the ZnO NRs-based assay in assessing cytokine levels useful for further clinical monitoring. Our research efforts demonstrate that ZnO NRs can be straightforwardly employed in the rapid, ultrasensitive, quantitative, and simultaneous detection of multiple AKI-related biomarkers directly in patient urine samples, providing an unparalleled detection capability beyond those of conventional analysis methods. Additional key advantages of the ZnO NRs-based approach include a fast detection speed, low-volume assay condition, multiplexing ability, and easy automation/integration capability to existing fluorescence instrumentation. Therefore, we anticipate that our ZnO NRs-based detection method will be highly beneficial for overcoming the frequent challenges in early biomarker development and treatment assessment, pertaining to the facile and ultrasensitive quantification of hard-to-trace biomolecules.Determining ultratrace amounts of protein biomarkers in patient samples in a straightforward and quantitative manner is extremely important for early disease diagnosis and treatment. Here, we successfully demonstrate the novel use of zinc oxide nanorods (ZnO NRs) in the ultrasensitive and quantitative detection of two acute kidney injury (AKI)-related protein biomarkers, tumor necrosis factor (TNF)-α and interleukin (IL)-8, directly from patient samples. We first validate the ZnO NRs-based IL-8 results via comparison with those obtained from using a conventional enzyme-linked immunosorbent method in samples from 38 individuals. We further assess the full detection capability of the ZnO NRs-based technique by quantifying TNF-α, whose levels in human urine are often below the detection limits of conventional methods. Using the ZnO NR platforms, we determine the TNF-α concentrations of all 46 patient samples tested, down to the fg per mL level. Subsequently, we screen for TNF-α levels in approximately 50 additional samples collected from different patient groups in order to demonstrate a potential use of the ZnO NRs-based assay in assessing cytokine levels useful for further clinical monitoring. Our research efforts demonstrate that ZnO NRs can be straightforwardly employed in the rapid, ultrasensitive, quantitative, and simultaneous detection of multiple AKI-related biomarkers directly in patient urine samples, providing an unparalleled detection capability beyond those of conventional analysis methods. Additional key advantages of the ZnO NRs-based approach include a fast detection speed, low-volume assay condition, multiplexing ability, and easy automation/integration capability to existing fluorescence instrumentation. Therefore, we anticipate that our ZnO NRs-based detection method will be highly beneficial for overcoming the frequent challenges in early biomarker development and treatment assessment, pertaining to the facile and ultrasensitive quantification of hard-to-trace biomolecules. Electronic supplementary information (ESI) available: Typical SEM images of the ZnO NRs used in the biomarker assays are provided in Fig. S1. See DOI: 10.1039/c5nr08706f

  8. Time-dependent importance sampling in semiclassical initial value representation calculations for time correlation functions.

    PubMed

    Tao, Guohua; Miller, William H

    2011-07-14

    An efficient time-dependent importance sampling method is developed for the Monte Carlo calculation of time correlation functions via the initial value representation (IVR) of semiclassical (SC) theory. A prefactor-free time-dependent sampling function weights the importance of a trajectory based on the magnitude of its contribution to the time correlation function, and global trial moves are used to facilitate the efficient sampling the phase space of initial conditions. The method can be generally applied to sampling rare events efficiently while avoiding being trapped in a local region of the phase space. Results presented in the paper for two system-bath models demonstrate the efficiency of this new importance sampling method for full SC-IVR calculations.

  9. A robust variable sampling time BLDC motor control design based upon μ-synthesis.

    PubMed

    Hung, Chung-Wen; Yen, Jia-Yush

    2013-01-01

    The variable sampling rate system is encountered in many applications. When the speed information is derived from the position marks along the trajectory, one would have a speed dependent sampling rate system. The conventional fixed or multisampling rate system theory may not work in these cases because the system dynamics include the uncertainties which resulted from the variable sampling rate. This paper derived a convenient expression for the speed dependent sampling rate system. The varying sampling rate effect is then translated into multiplicative uncertainties to the system. The design then uses the popular μ-synthesis process to achieve a robust performance controller design. The implementation on a BLDC motor demonstrates the effectiveness of the design approach.

  10. A Robust Variable Sampling Time BLDC Motor Control Design Based upon μ-Synthesis

    PubMed Central

    Yen, Jia-Yush

    2013-01-01

    The variable sampling rate system is encountered in many applications. When the speed information is derived from the position marks along the trajectory, one would have a speed dependent sampling rate system. The conventional fixed or multisampling rate system theory may not work in these cases because the system dynamics include the uncertainties which resulted from the variable sampling rate. This paper derived a convenient expression for the speed dependent sampling rate system. The varying sampling rate effect is then translated into multiplicative uncertainties to the system. The design then uses the popular μ-synthesis process to achieve a robust performance controller design. The implementation on a BLDC motor demonstrates the effectiveness of the design approach. PMID:24327804

  11. Gaussian Boson Sampling.

    PubMed

    Hamilton, Craig S; Kruse, Regina; Sansoni, Linda; Barkhofen, Sonja; Silberhorn, Christine; Jex, Igor

    2017-10-27

    Boson sampling has emerged as a tool to explore the advantages of quantum over classical computers as it does not require universal control over the quantum system, which favors current photonic experimental platforms. Here, we introduce Gaussian Boson sampling, a classically hard-to-solve problem that uses squeezed states as a nonclassical resource. We relate the probability to measure specific photon patterns from a general Gaussian state in the Fock basis to a matrix function called the Hafnian, which answers the last remaining question of sampling from Gaussian states. Based on this result, we design Gaussian Boson sampling, a #P hard problem, using squeezed states. This demonstrates that Boson sampling from Gaussian states is possible, with significant advantages in the photon generation probability, compared to existing protocols.

  12. Integrated fiducial sample mount and software for correlated microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Timothy R McJunkin; Jill R. Scott; Tammy L. Trowbridge

    2014-02-01

    A novel design sample mount with integrated fiducials and software for assisting operators in easily and efficiently locating points of interest established in previous analytical sessions is described. The sample holder and software were evaluated with experiments to demonstrate the utility and ease of finding the same points of interest in two different microscopy instruments. Also, numerical analysis of expected errors in determining the same position with errors unbiased by a human operator was performed. Based on the results, issues related to acquiring reproducibility and best practices for using the sample mount and software were identified. Overall, the sample mountmore » methodology allows data to be efficiently and easily collected on different instruments for the same sample location.« less

  13. Detection and Molecular Characterization of Gemycircularvirus from Environmental Samples in Brazil.

    PubMed

    da Silva Assis, Matheus Ribeiro; Vieira, Carmen Baur; Fioretti, Julia Monassa; Rocha, Mônica Simões; de Almeida, Pedro Ivo Neves; Miagostovich, Marize Pereira; Fumian, Tulio Machado

    2016-12-01

    Gemycircularvirus (GemyCV) is a group of viruses which has been recently proposed as a new viral genus detected in fecal and environmental samples around the world. GemyCVs have been detected in human blood, brain tissue, cerebrospinal fluid, and stool sample. In the present study, we demonstrate for the first time, through molecular detection and characterization, the presence of GemyCVs in environmental samples from Brazil. Our results show a percentage of positivity ranging from 69 (25/36) to 97 % (35/36) in river water samples collected in Manaus, Amazon region, and wastewater from a wastewater treatment plant located in Rio de Janeiro, respectively, revealing GemyCVs as an important environmental contaminant.

  14. Sampling and sample processing in pesticide residue analysis.

    PubMed

    Lehotay, Steven J; Cook, Jo Marie

    2015-05-13

    Proper sampling and sample processing in pesticide residue analysis of food and soil have always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agrochemical industry and contract laboratories. As global food trade and the importance of monitoring increase, the food industry and regulatory laboratories are also considering miniaturized high-throughput methods. In conjunction with a summary of the symposium "Residues in Food and Feed - Going from Macro to Micro: The Future of Sample Processing in Residue Analytical Methods" held at the 13th IUPAC International Congress of Pesticide Chemistry, this is an opportune time to review sampling theory and sample processing for pesticide residue analysis. If collected samples and test portions do not adequately represent the actual lot from which they came and provide meaningful results, then all costs, time, and efforts involved in implementing programs using sophisticated analytical instruments and techniques are wasted and can actually yield misleading results. This paper is designed to briefly review the often-neglected but crucial topic of sample collection and processing and put the issue into perspective for the future of pesticide residue analysis. It also emphasizes that analysts should demonstrate the validity of their sample processing approaches for the analytes/matrices of interest and encourages further studies on sampling and sample mass reduction to produce a test portion.

  15. Small sample estimation of the reliability function for technical products

    NASA Astrophysics Data System (ADS)

    Lyamets, L. L.; Yakimenko, I. V.; Kanishchev, O. A.; Bliznyuk, O. A.

    2017-12-01

    It is demonstrated that, in the absence of big statistic samples obtained as a result of testing complex technical products for failure, statistic estimation of the reliability function of initial elements can be made by the moments method. A formal description of the moments method is given and its advantages in the analysis of small censored samples are discussed. A modified algorithm is proposed for the implementation of the moments method with the use of only the moments at which the failures of initial elements occur.

  16. Biomonitoring of lead, zinc, and cadmium in streams draining lead-mining and non-mining areas, Southeast Missouri, USA

    USGS Publications Warehouse

    Besser, John M.; Brumbaugh, William G.; May, Thomas W.; Schmitt, Christopher J.

    2007-01-01

    We evaluated exposure of aquatic biota to lead (Pb), zinc (Zn), and cadmium (Cd) in streams draining a Pb-mining district in southeast Missouri. Samples of plant biomass (detritus, periphyton, and filamentous algae), invertebrates (snails, crayfish, and riffle benthos), and two taxa of fish were collected from seven sites closest to mining areas (mining sites), four sites further downstream from mining (downstream sites), and eight reference sites in fall 2001. Samples of plant biomass from mining sites had highest metal concentrations, with means 10- to 60-times greater than those for reference sites. Mean metal concentrations in over 90% of samples of plant biomass from mining sites were significantly greater than those from reference sites. Mean concentrations of Pb, Zn, and Cd in most invertebrate samples from mining sites, and mean Pb concentrations in most fish samples from mining sites, were also significantly greater than those from reference sites. Concentrations of all three metals were lower in samples from downstream sites, but several samples of plant biomass from downstream sites had metal concentrations significantly greater than those from reference sites. Analysis of supplemental samples collected in the fall of 2002, a year of above-average stream discharge, had lower Pb concentrations and higher Cd concentrations than samples collected in 2001, near the end of a multi-year drought. Concentrations of Pb measured in fish and invertebrates collected from mining sites during 2001 and 2002 were similar to those measured at nearby sites in the 1970s, during the early years of mining in the Viburnum Trend. Results of this study demonstrate that long-term Pb mining activity in southeast Missouri has resulted in significantly elevated concentrations of Pb, Cd, and Zn in biota of receiving streams, compared to biota of similar streams without direct influence of mining. Our results also demonstrate that metal exposure in the study area differed significantly among sample types, habitats, and years, and that these factors should be carefully considered in the design of biomonitoring studies.

  17. Biomonitoring of lead, zinc, and cadmium in streams draining lead-mining and non-mining areas, Southeast Missouri, USA

    USGS Publications Warehouse

    Besser, J.M.; Brumbaugh, W.G.; May, T.W.; Schmitt, C.J.

    2007-01-01

    We evaluated exposure of aquatic biota to lead (Pb), zinc (Zn), and cadmium (Cd) in streams draining a Pb-mining district in southeast Missouri. Samples of plant biomass (detritus, periphyton, and filamentous algae), invertebrates (snails, crayfish, and riffle benthos), and two taxa of fish were collected from seven sites closest to mining areas (mining sites), four sites further downstream from mining (downstream sites), and eight reference sites in fall 2001. Samples of plant biomass from mining sites had highest metal concentrations, with means 10- to 60-times greater than those for reference sites. Mean metal concentrations in over 90% of samples of plant biomass from mining sites were significantly greater than those from reference sites. Mean concentrations of Pb, Zn, and Cd in most invertebrate samples from mining sites, and mean Pb concentrations in most fish samples from mining sites, were also significantly greater than those from reference sites. Concentrations of all three metals were lower in samples from downstream sites, but several samples of plant biomass from downstream sites had metal concentrations significantly greater than those from reference sites. Analysis of supplemental samples collected in the fall of 2002, a year of above-average stream discharge, had lower Pb concentrations and higher Cd concentrations than samples collected in 2001, near the end of a multi-year drought. Concentrations of Pb measured in fish and invertebrates collected from mining sites during 2001 and 2002 were similar to those measured at nearby sites in the 1970s, during the early years of mining in the Viburnum Trend. Results of this study demonstrate that long-term Pb mining activity in southeast Missouri has resulted in significantly elevated concentrations of Pb, Cd, and Zn in biota of receiving streams, compared to biota of similar streams without direct influence of mining. Our results also demonstrate that metal exposure in the study area differed significantly among sample types, habitats, and years, and that these factors should be carefully considered in the design of biomonitoring studies. ?? Springer Science+Business Media B.V. 2006.

  18. Demonstration of disinfection procedure for the development of accurate blood glucose meters in accordance with ISO 15197:2013

    PubMed Central

    Lin, Wen-Ye; Chang, Jung-Tzu; Chu, Chun-Feng

    2017-01-01

    Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3–5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future. PMID:28683148

  19. Demonstration of disinfection procedure for the development of accurate blood glucose meters in accordance with ISO 15197:2013.

    PubMed

    Lin, Shu-Ping; Lin, Wen-Ye; Chang, Jung-Tzu; Chu, Chun-Feng

    2017-01-01

    Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3-5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future.

  20. Rock Magnetic Fabrics, Paleomagnetic Vectors, and Rock Magnetic Cyclostratigraphy of the Marcellus FM, Sunbury PA

    NASA Astrophysics Data System (ADS)

    Minguez, D. A.; Kodama, K. P.

    2013-12-01

    We present the preliminary results of a multi-faceted rock magnetic study conducted on 195 samples from the Oatka Creek member of the Marcellus formation, where it has been extracted from the subsurface as a drill core near Sunbury, PA. Samples were oriented based on bedding attitude observed within the core and were removed from the core at a spacing of ≈0.25 meters starting from the base (depth ≈ 500 meters) and spanning 51 meters of stratigraphic section. The results of measurements of the anisotropy of magnetic susceptibility (AMS) consistently demonstrate a nearly triaxial fabric with maximum principal axes clustering east-west and horizontal in geographic coordinates, nearly parallel to the direction of bedding strike. AMS minimum principal axes cluster near the pole to the bedding plane. Anisotropy of anhysteretic remanence (AAR) applied with a 100 mT peak field and a 97 μT bias field in 9 orientations demonstrates a markedly different fabric, with maximum principal axis clustering north-south and horizontal in geographic coordinates. Minimum principal axes of AAR cluster steeply (~60-70 degrees) to the west. The discrepancy between AAR and AMS fabrics likely indicates the AMS is dominated by paramagnetic clays, and thus may be interpreted as an east-west intersection lineation of clay particles dipping gently north or south. Paleomagnetic directions obtained using Alternating Field (AF) demagnetization in 5 mT steps up to 110 mT demonstrates a high coercivity remanence (>35 mT) with a south and shallow direction (D= 183.4 I=-14.7). This result is consistent with previous studies of the Marcellus formation and the Devonian Catskill red beds. Thermal demagnetization experiments demonstrate a similar magnetization removed by temperatures between 250 and 350 degrees Celsius, however, continued heating results in the acquisition of strong, inconsistent magnetizations likely the result of oxidizing iron sulfides. Thermal demagnetization of orthogonal partial ARMs applied in 100 mT and 50 mT peak fields was conducted on a subset of samples sealed in aluminum foil with alumina-silica cement to prevent oxidization. The results demonstrate that the low coercivity pARM is removed by 400 degrees Celsius and the high coercivity pARM, which is only 10% of the total remanence, is removed by 600 degrees Celsius. The results suggest the presence of low coercivity Fe sulfides and high coercivity magnetite. Lastly, time series analysis of bulk magnetic susceptibility using the Multi-Taper Method (MTM) demonstrates oscillations with a wavelength of 18 meters above the 99% confidence level with respect to the robust red noise. This wavelength may have a duration of 405 kyr given ancillary chronostratigraphic evidence.

  1. Commutability of food microbiology proficiency testing samples.

    PubMed

    Abdelmassih, M; Polet, M; Goffaux, M-J; Planchon, V; Dierick, K; Mahillon, J

    2014-03-01

    Food microbiology proficiency testing (PT) is a useful tool to assess the analytical performances among laboratories. PT items should be close to routine samples to accurately evaluate the acceptability of the methods. However, most PT providers distribute exclusively artificial samples such as reference materials or irradiated foods. This raises the issue of the suitability of these samples because the equivalence-or 'commutability'-between results obtained on artificial vs. authentic food samples has not been demonstrated. In the clinical field, the use of noncommutable PT samples has led to erroneous evaluation of the performances when different analytical methods were used. This study aimed to provide a first assessment of the commutability of samples distributed in food microbiology PT. REQUASUD and IPH organized 13 food microbiology PTs including 10-28 participants. Three types of PT items were used: genuine food samples, sterile food samples and reference materials. The commutability of the artificial samples (reference material or sterile samples) was assessed by plotting the distribution of the results on natural and artificial PT samples. This comparison highlighted matrix-correlated issues when nonfood matrices, such as reference materials, were used. Artificially inoculated food samples, on the other hand, raised only isolated commutability issues. In the organization of a PT-scheme, authentic or artificially inoculated food samples are necessary to accurately evaluate the analytical performances. Reference materials, used as PT items because of their convenience, may present commutability issues leading to inaccurate penalizing conclusions for methods that would have provided accurate results on food samples. For the first time, the commutability of food microbiology PT samples was investigated. The nature of the samples provided by the organizer turned out to be an important factor because matrix effects can impact on the analytical results. © 2013 The Society for Applied Microbiology.

  2. Stable carbon and nitrogen isotope analysis of avian uric acid.

    PubMed

    Bird, Michael I; Tait, Elaine; Wurster, Christopher M; Furness, Robert W

    2008-11-01

    We report results obtained using a new technique developed to measure the stable-isotope composition of uric acid isolated from bird excreta (guano). Results from a diet-switch feeding trial using zebra finches suggest that the delta(13)C of uric acid in the guano equilibrates with the diet of the bird within 3 days of a change in diet, while the equilibration time for delta(15)N may be longer. The average carbon isotope discrimination between uric acid and food before the diet switch was +0.34 +/- 1 per thousand (1sigma) while after the diet switch this increased slightly to +0.83 +/- 0.7 per thousand (1sigma). Nitrogen isotope discrimination was +1.3 +/- 0.3 per thousand (1sigma) and +0.3 +/- 0.3 per thousand (1sigma) before and after the diet switch; however, it is possible that the nitrogen isotope values did not fully equilibrate with diet switch over the course of the experiment. Analyses of other chemical fractions of the guano (organic residue after uric acid extraction and non-uric acid organics solubilised during extraction) suggest a total range of up to 3 per thousand for both delta(13)C and delta(15)N values in individual components of a single bulk guano sample. The analysis of natural samples from a range of terrestrial and marine species demonstrates that the technique yields isotopic compositions consistent with the known diets of the birds. The results from natural samples further demonstrate that multiple samples from the same species collected from the same location yield similar results, while different species from the same location exhibit a range of isotopic compositions indicative of different dietary preferences. Given that many samples of guano can be rapidly collected without any requirement to capture specimens for invasive sampling, the stable-isotope analysis of uric acid offers a new, simple and potentially powerful tool for studying avian ecology and metabolism.

  3. Molecular diversity and distribution of marine fungi across 130 European environmental samples.

    PubMed

    Richards, Thomas A; Leonard, Guy; Mahé, Frédéric; Del Campo, Javier; Romac, Sarah; Jones, Meredith D M; Maguire, Finlay; Dunthorn, Micah; De Vargas, Colomban; Massana, Ramon; Chambouvet, Aurélie

    2015-11-22

    Environmental DNA and culture-based analyses have suggested that fungi are present in low diversity and in low abundance in many marine environments, especially in the upper water column. Here, we use a dual approach involving high-throughput diversity tag sequencing from both DNA and RNA templates and fluorescent cell counts to evaluate the diversity and relative abundance of fungi across marine samples taken from six European near-shore sites. We removed very rare fungal operational taxonomic units (OTUs) selecting only OTUs recovered from multiple samples for a detailed analysis. This approach identified a set of 71 fungal 'OTU clusters' that account for 66% of all the sequences assigned to the Fungi. Phylogenetic analyses demonstrated that this diversity includes a significant number of chytrid-like lineages that had not been previously described, indicating that the marine environment encompasses a number of zoosporic fungi that are new to taxonomic inventories. Using the sequence datasets, we identified cases where fungal OTUs were sampled across multiple geographical sites and between different sampling depths. This was especially clear in one relatively abundant and diverse phylogroup tentatively named Novel Chytrid-Like-Clade 1 (NCLC1). For comparison, a subset of the water column samples was also investigated using fluorescent microscopy to examine the abundance of eukaryotes with chitin cell walls. Comparisons of relative abundance of RNA-derived fungal tag sequences and chitin cell-wall counts demonstrate that fungi constitute a low fraction of the eukaryotic community in these water column samples. Taken together, these results demonstrate the phylogenetic position and environmental distribution of 71 lineages, improving our understanding of the diversity and abundance of fungi in marine environments. © 2015 The Authors.

  4. Molecular diversity and distribution of marine fungi across 130 European environmental samples

    PubMed Central

    Richards, Thomas A.; Leonard, Guy; Mahé, Frédéric; del Campo, Javier; Romac, Sarah; Jones, Meredith D. M.; Maguire, Finlay; Dunthorn, Micah; De Vargas, Colomban; Massana, Ramon; Chambouvet, Aurélie

    2015-01-01

    Environmental DNA and culture-based analyses have suggested that fungi are present in low diversity and in low abundance in many marine environments, especially in the upper water column. Here, we use a dual approach involving high-throughput diversity tag sequencing from both DNA and RNA templates and fluorescent cell counts to evaluate the diversity and relative abundance of fungi across marine samples taken from six European near-shore sites. We removed very rare fungal operational taxonomic units (OTUs) selecting only OTUs recovered from multiple samples for a detailed analysis. This approach identified a set of 71 fungal ‘OTU clusters' that account for 66% of all the sequences assigned to the Fungi. Phylogenetic analyses demonstrated that this diversity includes a significant number of chytrid-like lineages that had not been previously described, indicating that the marine environment encompasses a number of zoosporic fungi that are new to taxonomic inventories. Using the sequence datasets, we identified cases where fungal OTUs were sampled across multiple geographical sites and between different sampling depths. This was especially clear in one relatively abundant and diverse phylogroup tentatively named Novel Chytrid-Like-Clade 1 (NCLC1). For comparison, a subset of the water column samples was also investigated using fluorescent microscopy to examine the abundance of eukaryotes with chitin cell walls. Comparisons of relative abundance of RNA-derived fungal tag sequences and chitin cell-wall counts demonstrate that fungi constitute a low fraction of the eukaryotic community in these water column samples. Taken together, these results demonstrate the phylogenetic position and environmental distribution of 71 lineages, improving our understanding of the diversity and abundance of fungi in marine environments. PMID:26582030

  5. Perfluoro(Methylcyclohexane) Tracer Tagging Test and Demonstration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sigman, M.E.

    On February 14 and 15, 2000, a demonstration of current perfluorocarbon tagging technology and the future potential of these methods was held at Oak Ridge National Laboratory (ORNL). The demonstration consisted of a brief technical discussion followed by a laboratory demonstration. The laboratory demonstrations included the detection of letters, parcels, briefcases and lockers containing perfluorocarbon-tagged papers. Discrimination between tagged and non-tagged items and between three perfluorocarbon tags was demonstrated along with the detection of perfluorocarbon in a background of non-fluorinated volatile organic solvent. All demonstrations involved real-time detection using a direct sampling ion trap mass spectrometer. The technical results obtainedmore » at ORNL during and in preparation for the demonstration are presented in Appendix 1 to assist Tracer Detection Technology Corp. in further evaluating their position on development and marketing of perfluorocarbon tracer technology.« less

  6. High-throughput sequencing of forensic genetic samples using punches of FTA cards with buccal swabs.

    PubMed

    Kampmann, Marie-Louise; Buchard, Anders; Børsting, Claus; Morling, Niels

    2016-01-01

    Here, we demonstrate that punches from buccal swab samples preserved on FTA cards can be used for high-throughput DNA sequencing, also known as massively parallel sequencing (MPS). We typed 44 reference samples with the HID-Ion AmpliSeq Identity Panel using washed 1.2 mm punches from FTA cards with buccal swabs and compared the results with those obtained with DNA extracted using the EZ1 DNA Investigator Kit. Concordant profiles were obtained for all samples. Our protocol includes simple punch, wash, and PCR steps, reducing cost and hands-on time in the laboratory. Furthermore, it facilitates automation of DNA sequencing.

  7. Sample-space-based feature extraction and class preserving projection for gene expression data.

    PubMed

    Wang, Wenjun

    2013-01-01

    In order to overcome the problems of high computational complexity and serious matrix singularity for feature extraction using Principal Component Analysis (PCA) and Fisher's Linear Discrinimant Analysis (LDA) in high-dimensional data, sample-space-based feature extraction is presented, which transforms the computation procedure of feature extraction from gene space to sample space by representing the optimal transformation vector with the weighted sum of samples. The technique is used in the implementation of PCA, LDA, Class Preserving Projection (CPP) which is a new method for discriminant feature extraction proposed, and the experimental results on gene expression data demonstrate the effectiveness of the method.

  8. Experimental light scattering by ultrasonically controlled small particles - Implications for Planetary Science

    NASA Astrophysics Data System (ADS)

    Gritsevich, M.; Penttilä, A.; Maconi, G.; Kassamakov, I.; Markkanen, J.; Martikainen, J.; Väisänen, T.; Helander, P.; Puranen, T.; Salmi, A.; Hæggström, E.; Muinonen, K.

    2017-09-01

    We present the results obtained with our newly developed 3D scatterometer - a setup for precise multi-angular measurements of light scattered by mm- to µm-sized samples held in place by sound. These measurements are cross-validated against the modeled light-scattering characteristics of the sample, i.e., the intensity and the degree of linear polarization of the reflected light, calculated with state-of-the-art electromagnetic techniques. We demonstrate a unique non-destructive approach to derive the optical properties of small grain samples which facilitates research on highly valuable planetary materials, such as samples returned from space missions or rare meteorites.

  9. A Monte-Carlo method which is not based on Markov chain algorithm, used to study electrostatic screening of ion potential

    NASA Astrophysics Data System (ADS)

    Šantić, Branko; Gracin, Davor

    2017-12-01

    A new simple Monte Carlo method is introduced for the study of electrostatic screening by surrounding ions. The proposed method is not based on the generally used Markov chain method for sample generation. Each sample is pristine and there is no correlation with other samples. As the main novelty, the pairs of ions are gradually added to a sample provided that the energy of each ion is within the boundaries determined by the temperature and the size of ions. The proposed method provides reliable results, as demonstrated by the screening of ion in plasma and in water.

  10. Remaining Sites Verification Package for the 100-F-26:10, 1607-F3 Sanitary Sewer Pipelines (182-F, 183-F, and 151-F Sanitary Sewer Lines), Waste Site Reclassification Form 2007-028

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    L. M. Dittmer

    2007-12-03

    The 100-F-26:10 waste site includes sanitary sewer lines that serviced the former 182-F, 183-F, and 151-F Buildings. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

  11. Remaining Sites Verification Package for the 100-F-26:15 Miscellaneous Pipelines Associated with the 132-F-6, 1608-F Waste Water Pumping Station, Waste Site Reclassification Form 2007-031

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    L. M. Dittmer

    2008-03-18

    The 100-F-26:15 waste site consisted of the remnant portions of underground process effluent and floor drain pipelines that originated at the 105-F Reactor. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

  12. Soft tissue adhesion of polished versus glazed lithium disilicate ceramic for dental applications.

    PubMed

    Brunot-Gohin, C; Duval, J-L; Azogui, E-E; Jannetta, R; Pezron, I; Laurent-Maquin, D; Gangloff, S C; Egles, C

    2013-09-01

    Ceramics are widely used materials for prosthesis, especially in dental fields. Despite multiple biomedical applications, little is known about ceramic surface modifications and the resulting cell behavior at its contact. The aim of this study is to evaluate the biological response of polished versus glazed surface treatments on lithium disilicate dental ceramic. We studied a lithium disilicate ceramic (IPS e.max(®) Press, Ivoclar Vivadent) with 3 different surface treatments: raw surface treatment, hand polished surface treatment, and glazed surface treatment (control samples are Thermanox(®), Nunc). In order to evaluate the possible modulation of cell response at the surface of ceramic, we compared polished versus glazed ceramics using an organotypic culture model of chicken epithelium. Our results show that the surface roughness is not modified as demonstrated by equivalent Ra measurements. On the contrary, the contact angle θ in water is very different between polished (84°) and glazed (33°) samples. The culture of epithelial tissues allowed a very precise assessment of histocompatibility of these interfaces and showed that polished samples increased cell adhesion and proliferation as compared to glazed samples. Lithium disilicate polished ceramic provided better adhesion and proliferation than lithium disilicate glazed ceramic. Taken together, our results demonstrate for the first time, how it is possible to use simple surface modifications to finely modulate the adhesion of tissues. Our results will help dental surgeons to choose the most appropriate surface treatment for a specific clinical application, in particular for the ceramic implant collar. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  13. Height-resolved large-sample INAA of a 1 m long, 13 cm diameter ditch-bottom sample

    NASA Astrophysics Data System (ADS)

    Blaauw, M.; Baas, H. W.; Donze, M.

    2003-06-01

    A facility for instrumental neutron activation analysis (INAA) of large samples (up to 1 m long and 15 cm diameter) has been built. Correction methods for the simultaneous occurrence of neutron self-shielding and gamma-ray self-attenuation effects have been implemented and tested with a variety of samples. Now, the method has been extended to allow for the interpretation of scanned, collimated measurements, where results are obtained for individual voxels. As a validation and demonstration, a ditch-bottom sample of the maximum size was taken in a frozen condition. It was cut in 2 cm slices, still frozen, and put together again with each slice in a 2 cm height Petri dish divided in three sections. This allowed for verification of the results by ordinary INAA. Possible explanations for the discrepancies we observed between ordinary and large-sample INAA in the region where the concentration gradients are the steepest are discussed.

  14. Preanalytical considerations in detection of colorectal cancer in blood serum using Raman molecular imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Treado, Patrick J.; Stewart, Shona D.; Smith, Aaron; Kirschner, Heather; Post, Christopher; Overholt, Bergein F.

    2016-03-01

    Colorectal cancer (CRC) is the third most common cancer in men and women in the United States. Raman Molecular Imaging (RMI) is an effective technique to evaluate human tissue, cells and bodily fluids, including blood serum for disease diagnosis. ChemImage Corporation, in collaboration with clinicians, has been engaged in development of an in vitro diagnostic Raman assay focused on CRC detection. The Raman Assay for Colorectal Cancer (RACC) exploits the high specificity of Raman imaging to distinguish diseased from normal dried blood serum droplets without additional reagents. Pilot Study results from testing of hundreds of biobank patient samples have demonstrated that RACC detects CRC with high sensitivity and specificity. However, expanded clinical trials, which are ongoing, are revealing a host of important preanalytical considerations associated with sample collection, sample storage and stability, sample shipping, sample preparation and sample interferents, which impact detection performance. Results from recent clinical studies will be presented.

  15. Evidence of a sewer vapor transport pathway at the USEPA vapor intrusion research duplex.

    PubMed

    McHugh, Thomas; Beckley, Lila; Sullivan, Terry; Lutes, Chris; Truesdale, Robert; Uppencamp, Rob; Cosky, Brian; Zimmerman, John; Schumacher, Brian

    2017-11-15

    The role of sewer lines as preferential pathways for vapor intrusion is poorly understood. Although the importance of sewer lines for volatile organic compound (VOC) transport has been documented at a small number of sites with vapor intrusion, sewer lines are not routinely sampled during most vapor intrusion investigations. We have used a tracer study and VOC concentration measurements to evaluate the role of the combined sanitary/storm sewer line in VOC transport at the USEPA vapor intrusion research duplex in Indianapolis, Indiana. The results from the tracer study demonstrated gas migration from the sewer main line into the duplex. The migration pathway appears to be complex and may include leakage from the sewer lateral at a location below the building foundation. Vapor samples collected from the sewer line demonstrated the presence of tetrachloroethene (PCE) and chloroform in the sewer main in front of the duplex and at multiple sample locations within the sewer line upstream of the duplex. These test results combined with results from the prior multi-year study of the duplex indicate that the sewer line plays an important role in transport of VOCs from the subsurface source to the immediate vicinity of the duplex building envelope. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Evidence of a sewer vapor transport pathway at the USEPA vapor intrusion research duplex

    DOE PAGES

    McHugh, Thomas; Beckley, Lila; Sullivan, Terry; ...

    2017-04-26

    We report the role of sewer lines as preferential pathways for vapor intrusion is poorly understood. Although the importance of sewer lines for volatile organic compound (VOC) transport has been documented at a small number of sites with vapor intrusion, sewer lines are not routinely sampled during most vapor intrusion investigations. We have used a tracer study and VOC concentration measurements to evaluate the role of the combined sanitary/storm sewer line in VOC transport at the USEPA vapor intrusion research duplex in Indianapolis, Indiana. The results from the tracer study demonstrated gas migration from the sewer main line into themore » duplex. The migration pathway appears to be complex and may include leakage from the sewer lateral at a location below the building foundation. Vapor samples collected from the sewer line demonstrated the presence of tetrachloroethene (PCE) and chloroform in the sewer main in front of the duplex and at multiple sample locations within the sewer line upstream of the duplex. Finally, these test results combined with results from the prior multi-year study of the duplex indicate that the sewer line plays an important role in transport of VOCs from the subsurface source to the immediate vicinity of the duplex building envelope.« less

  17. Evidence of a sewer vapor transport pathway at the USEPA vapor intrusion research duplex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McHugh, Thomas; Beckley, Lila; Sullivan, Terry

    We report the role of sewer lines as preferential pathways for vapor intrusion is poorly understood. Although the importance of sewer lines for volatile organic compound (VOC) transport has been documented at a small number of sites with vapor intrusion, sewer lines are not routinely sampled during most vapor intrusion investigations. We have used a tracer study and VOC concentration measurements to evaluate the role of the combined sanitary/storm sewer line in VOC transport at the USEPA vapor intrusion research duplex in Indianapolis, Indiana. The results from the tracer study demonstrated gas migration from the sewer main line into themore » duplex. The migration pathway appears to be complex and may include leakage from the sewer lateral at a location below the building foundation. Vapor samples collected from the sewer line demonstrated the presence of tetrachloroethene (PCE) and chloroform in the sewer main in front of the duplex and at multiple sample locations within the sewer line upstream of the duplex. Finally, these test results combined with results from the prior multi-year study of the duplex indicate that the sewer line plays an important role in transport of VOCs from the subsurface source to the immediate vicinity of the duplex building envelope.« less

  18. Meticulous plasma isolation is essential to avoid false low-level viraemia in Roche Cobas HIV-1 viral load assays.

    PubMed

    Mortier, Virginie; Vancoillie, Leen; Dauwe, Kenny; Staelens, Delfien; Demecheleer, Els; Schauvliege, Marlies; Dinakis, Sylvie; Van Maerken, Tom; Dessilly, Géraldine; Ruelle, Jean; Verhofstede, Chris

    2017-10-24

    Pre-analytical sample processing is often overlooked as a potential cause of inaccurate assay results. Here we demonstrate how plasma, extracted from standard EDTA-containing blood collection tubes, may contain traces of blood cells consequently resulting in a false low-level HIV-1 viral load when using Roche Cobas HIV-1 assays. The presence of human DNA in Roche Cobas 4800 RNA extracts and in RNA extracts from the Abbott HIV-1 RealTime assay was assessed by quantifying the human albumin gene by means of quantitative PCR. RNA was extracted from plasma samples before and after an additional centrifugation and tested for viral load and DNA contamination. The relation between total DNA content and viral load was defined. Elevated concentrations of genomic DNA were detected in 28 out of 100 Cobas 4800 extracts and were significantly more frequent in samples processed outside of the AIDS Reference Laboratory. An association between genomic DNA presence and spurious low-level viraemia results was demonstrated. Supplementary centrifugation of plasma before RNA extraction eliminated the contamination and the false viraemia. Plasma isolated from standard EDTA-containing blood collection tubes may contain traces of HIV DNA leading to false viral load results above the clinical cutoff. Supplementary centrifugation of plasma before viral load analysis may eliminate the occurrence of this spurious low-level viraemia.

  19. Comparison of Three Enzyme-Linked Immunosorbent Assays for Detection of Immunoglobulin G Antibodies to Tetanus Toxoid with Reference Standards and the Impact on Clinical Practice▿

    PubMed Central

    van Hoeven, Karen H.; Dale, Connie; Foster, Phil; Body, Barbara

    2008-01-01

    Accurate determination of the concentrations of immunoglobulin G (IgG) antibody to tetanus toxoid is important in order to evaluate the immunogenicity of tetanus toxoid vaccines, determine immune competence in individual patients, and measure the prevalence of immunity in populations. The performance of three commercially available enzyme-linked immunosorbent assays (ELISAs) for IgG antibodies to tetanus toxoid were evaluated. Serially diluted NIBSC 76/589 and TE-3 human tetanus IgG immunoglobulin international reference standards were analyzed in quadruplicate using ELISAs manufactured by The Binding Site, Inc. (VaccZyme); Scimedx; and Euroimmun. In addition, IgG antibodies to tetanus toxoid were measured in 83 deidentified serum specimens using each manufacturer's ELISA. Each ELISA provided linear results when evaluated with the reference preparations. The Binding Site ELISA provided results that closely corresponded to the reference preparations (y = 1.09x − 0.08), whereas the Scimedx ELISA gave results that were consistently lower (y = 0.21x − 0.07) and the Euroimmun ELISA gave results that were consistently higher (y = 1.5x + 0.30) than the reference preparation concentrations. Using the recommended cutoff for each ELISA (<0.10 IU/ml), the overall agreement of all of the ELISA methods was 78%. Three of eighty-three (3.6%) human serum samples demonstrated inadequate immunity with all three assays. The Binding Site ELISA yielded nonprotective antibody concentrations in only these 3 samples, whereas 19 samples (22.9%) according to the Scimedx ELISA and 6 samples (7.2%) according to the Euroimmun ELISA demonstrated nonprotective concentrations. The performance characteristics of ELISAs for tetanus immunoglobulin titers were manufacturer dependent, and the differences translated into important disparities in reported results. PMID:18845832

  20. Multiscale/Multifunctional Probabilistic Composite Fatigue

    NASA Technical Reports Server (NTRS)

    Chamis, Christos C.

    2010-01-01

    A multilevel (multiscale/multifunctional) evaluation is demonstrated by applying it to three different sample problems. These problems include the probabilistic evaluation of a space shuttle main engine blade, an engine rotor and an aircraft wing. The results demonstrate that the blade will fail at the highest probability path, the engine two-stage rotor will fail by fracture at the rim and the aircraft wing will fail at 109 fatigue cycles with a probability of 0.9967.

  1. Durable flame retardant finish for silk fabric using boron hybrid silica sol

    NASA Astrophysics Data System (ADS)

    Zhang, Qiang-hua; Gu, Jiali; Chen, Guo-qiang; Xing, Tie-ling

    2016-11-01

    A hybrid silica sol was prepared via sol gel method using tetraethoxysilane (TEOS) as a precursor and boric acid (H3BO3) as flame retardant additive and then applied to silk fabric. In order to endow silk fabric with durable flame retardancy, 1,2,3,4-butanetetracarboxylic acid (BTCA) was used as cross-linking agent for the sake of strong linkage formation between the hybrid silica sol and silk fabric. The FT-IR and XPS analysis demonstrated the Si-O-B formation in the sol system, as well as the linkage between the sol and silk after the treatment. The limiting oxygen index (LOI) and smoke density test indicated good flame retardancy and smoke suppression of the treated silk fabrics. The micro calorimeter combustion (MCC) test and thermo gravimetric (TG) analysis showed that the treated samples had less weight loss in the high temperature and lower heat release rate when burning. The washing durability evaluation results indicated that there was a distinct improvement for the silk samples treated with BTCA even after 30 times washing. In addition, the influence of the processing order of BTCA and silica sol treatment on the limiting oxygen index (LOI) of the finished silk fabric was also investigated. And the results demonstrated that the sample treated with BTCA first and then with the silica sol exhibited better LOI value (32.3%) than that of the sample by the conversed treatment order. Moreover the tensile property of treated samples was nearly unchanged, but the handle of sol treated samples obviously decreased.

  2. Demonstration of LED Retrofit Lamps at the Smithsonian American Art Museum, Washington, DC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Naomi J.; Rosenfeld, Scott M.

    This report documents observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy GATEWAY Solid-State Lighting (SSL) Technology Demonstration Program at the Smithsonain American Art Museum in Washington, DC. LED Lamp samples were tested in the museum workshop, temporarily installed in a gallery for feedback, and ultimately replaced all traditional incandescent lamps in one gallery of modernist art at the American Art Museum and partially replacing lamps in two galleries at the Musesum's Renwick Gallery. This report describes the selection and testing process, technology challenges, perceptions, economics, energy use, and mixed results of usignmore » LED replacement lamps in art galleries housing national treasures.« less

  3. Demonstrated Potential of Ion Mobility Spectrometry for Detection of Adulterated Perfumes and Plant Speciation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clark, Jared Matthew; Daum, Keith Alvin; Kalival, J. H.

    2003-01-01

    This initial study evaluates the use of ion mobility spectrometry (IMS) as a rapid test procedure for potential detection of adulterated perfumes and speciation of plant life. Sample types measured consist of five genuine perfumes, two species of sagebrush, and four species of flowers. Each sample type is treated as a separate classification problem. It is shown that discrimination using principal component analysis with K-nearest neighbors can distinguish one class from another. Discriminatory models generated using principal component regressions are not as effective. Results from this examination are encouraging and represent an initial phase demonstrating that perfumes and plants possessmore » characteristic chemical signatures that can be used for reliable identification.« less

  4. Dynamics of CFCs in northern temperate lakes and adjacent groundwater

    USGS Publications Warehouse

    Walker, John F.; Saad, David A.; Hunt, Randall J.

    2007-01-01

    Three dimictic lakes and one meromictic lake in and near the Trout Lake, Wisconsin, watershed were sampled to determine the variation of chlorofluorocarbon (CFC) concentrations within the lakes. The lakes were sampled during stratified conditions, during fall turnover, and during ice cover. The results demonstrate a considerable variation in CFC concentrations and corresponding atmospheric mixing ratios in the lakes sampled, both with depth and season within a given lake, and across different lakes. CFC profiles and observed degradation were not related to the groundwater inflow rate and hence are likely the result of in‐lake processes influenced by CFC degradation in the (lake) water column, CFC degradation in the lake‐bed sediments, and gas exchange rates and the duration of turnover (turnover efficiency).

  5. Synthesis and characterisation of mucoadhesive thiolated polyallylamine.

    PubMed

    Duggan, Sarah; Hughes, Helen; Owens, Eleanor; Duggan, Elaine; Cummins, Wayne; O' Donovan, Orla

    2016-02-29

    The thiolation of polyallylamine (PAAm) for use in mucoadhesive drug delivery has been achieved. PAAm was reacted with different ratios of Traut's reagent, yielding products with thiol contents ranging from 134-487μmol/g. Full mucoadhesive characterisation of the thiolated PAAm samples was conducted using swelling studies, mucoadhesive testing on porcine intestinal tissue and rheology. Both swelling and cohesive properties of the thiolated PAAm products were vastly improved in comparison to an unmodified PAAm control. The swelling abilities of the thiolated samples were high and the degree of thiolation of the products affected the initial rate of swelling. High levels of mucoadhesion were demonstrated by the thiolated PAAm samples, with adhesion times of greater than 24h measured for all three samples and, thus, thiol content did not appear to influence mucoadhesion. Rheological studies of the thiolated PAAm samples showed an increase in G' and G″ values upon the addition of a mucin solution which was not observed in the unmodified control, again highlighting the mucoadhesive interactions between these thiolated polymers and mucin. The synthesis of thiolated PAAm by reaction with Traut's reagent and resulting mucoadhesive properties demonstrates its potential for use a mucoadhesive drug delivery device. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Rapid detection of bacteria with miniaturized pyrolysis-gas chromatographic analysis

    NASA Astrophysics Data System (ADS)

    Mowry, Curtis; Morgan, Catherine H.; Baca, Quentin; Manginell, Ronald P.; Kottenstette, Richard J.; Lewis, Patrick; Frye-Mason, Gregory C.

    2002-02-01

    Rapid detection and identification of bacteria and other pathogens is important for many civilian and military applications. The profiles of biological markers such as fatty acids can be used to characterize biological samples or to distinguish bacteria at the gram-type, genera, and even species level. Common methods for whole cell bacterial analysis are neither portable nor rapid, requiring lengthy, labor intensive sample preparation and bench-scale instrumentation. These methods chemically derivatize fatty acids to produce more volatile fatty acid methyl esters (FAMEs) that can be separated and analyzed by a gas chromatograph (GC)/mass spectrometer. More recent publications demonstrate decreased sample preparation time with in situ derivatization of whole bacterial samples using pyrolysis/derivatization. Ongoing development of miniaturized pyrolysis/GC instrumentation by this department capitalizes on Sandia advances in the field of microfabricated chemical analysis systems ((mu) ChemLab). Microdevices include rapidly heated stages capable of pyrolysis or sample concentration, gas chromatography columns, and surface acoustic wave (SAW) sensor arrays. We will present results demonstrating the capabilities of these devices toward fulfilling the goal of portable, rapid detection and early warning of the presence of pathogens in air or water.

  7. Sampling and analysis of aircraft engine cold start particles and demonstration of an electrostatic personal particle sampler.

    PubMed

    Armendariz, Alfredo; Leith, David; Boundy, Maryanne; Goodman, Randall; Smith, Les; Carlton, Gary

    2003-01-01

    Aircraft engines emit an aerosol plume during startup in extremely cold weather that can drift into areas occupied by flightline ground crews. This study tested a personal sampler used to assess exposure to particles in the plume under challenging field conditions. Area and personal samples were taken at two U.S. Air Force (USAF) flightlines during the winter months. Small tube-and-wire electrostatic precipitators (ESPs) were mounted on a stationary stand positioned behind the engines to sample the exhaust. Other ESPs were worn by ground crews to sample breathing zone concentrations. In addition, an aerodynamic particle sizer 3320 (APS) was used to determine the size distribution of the particles. Samples collected with the ESP were solvent extracted and analyzed with gas chromatography-mass spectrometry. Results indicated that the plume consisted of up to 75 mg/m(3) of unburned jet fuel particles. The APS showed that nearly the entire particle mass was respirable, because the plumes had mass median diameters less than 2 micro m. These tests demonstrated that the ESP could be used at cold USAF flightlines to perform exposure assessments to the cold start particles.

  8. Rapid, all-optical crystal orientation imaging of two-dimensional transition metal dichalcogenide monolayers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    David, Sabrina N.; Zhai, Yao; van der Zande, Arend M.

    Two-dimensional (2D) atomic materials such as graphene and transition metal dichalcogenides (TMDCs) have attracted significant research and industrial interest for their electronic, optical, mechanical, and thermal properties. While large-area crystal growth techniques such as chemical vapor deposition have been demonstrated, the presence of grain boundaries and orientation of grains arising in such growths substantially affect the physical properties of the materials. There is currently no scalable characterization method for determining these boundaries and orientations over a large sample area. We here present a second-harmonic generation based microscopy technique for rapidly mapping grain orientations and boundaries of 2D TMDCs. We experimentallymore » demonstrate the capability to map large samples to an angular resolution of ±1° with minimal sample preparation and without involved analysis. A direct comparison of the all-optical grain orientation maps against results obtained by diffraction-filtered dark-field transmission electron microscopy plus selected-area electron diffraction on identical TMDC samples is provided. This rapid and accurate tool should enable large-area characterization of TMDC samples for expedited studies of grain boundary effects and the efficient characterization of industrial-scale production techniques.« less

  9. The Lung Microbiome in Moderate and Severe Chronic Obstructive Pulmonary Disease

    PubMed Central

    Pragman, Alexa A.; Kim, Hyeun Bum; Reilly, Cavan S.; Wendt, Christine; Isaacson, Richard E.

    2012-01-01

    Chronic obstructive pulmonary disease (COPD) is an inflammatory disorder characterized by incompletely reversible airflow obstruction. Bacterial infection of the lower respiratory tract contributes to approximately 50% of COPD exacerbations. Even during periods of stable lung function, the lung harbors a community of bacteria, termed the microbiome. The role of the lung microbiome in the pathogenesis of COPD remains unknown. The COPD lung microbiome, like the healthy lung microbiome, appears to reflect microaspiration of oral microflora. Here we describe the COPD lung microbiome of 22 patients with Moderate or Severe COPD compared to 10 healthy control patients. The composition of the lung microbiomes was determined using 454 pyrosequencing of 16S rDNA found in bronchoalveolar lavage fluid. Sequences were analyzed using mothur, Ribosomal Database Project, Fast UniFrac, and Metastats. Our results showed a significant increase in microbial diversity with the development of COPD. The main phyla in all samples were Actinobacteria, Firmicutes, and Proteobacteria. Principal coordinate analyses demonstrated separation of control and COPD samples, but samples did not cluster based on disease severity. However, samples did cluster based on the use of inhaled corticosteroids and inhaled bronchodilators. Metastats analyses demonstrated an increased abundance of several oral bacteria in COPD samples. PMID:23071781

  10. Optimization of groundwater sampling approach under various hydrogeological conditions using a numerical simulation model

    NASA Astrophysics Data System (ADS)

    Qi, Shengqi; Hou, Deyi; Luo, Jian

    2017-09-01

    This study presents a numerical model based on field data to simulate groundwater flow in both the aquifer and the well-bore for the low-flow sampling method and the well-volume sampling method. The numerical model was calibrated to match well with field drawdown, and calculated flow regime in the well was used to predict the variation of dissolved oxygen (DO) concentration during the purging period. The model was then used to analyze sampling representativeness and sampling time. Site characteristics, such as aquifer hydraulic conductivity, and sampling choices, such as purging rate and screen length, were found to be significant determinants of sampling representativeness and required sampling time. Results demonstrated that: (1) DO was the most useful water quality indicator in ensuring groundwater sampling representativeness in comparison with turbidity, pH, specific conductance, oxidation reduction potential (ORP) and temperature; (2) it is not necessary to maintain a drawdown of less than 0.1 m when conducting low flow purging. However, a high purging rate in a low permeability aquifer may result in a dramatic decrease in sampling representativeness after an initial peak; (3) the presence of a short screen length may result in greater drawdown and a longer sampling time for low-flow purging. Overall, the present study suggests that this new numerical model is suitable for describing groundwater flow during the sampling process, and can be used to optimize sampling strategies under various hydrogeological conditions.

  11. Free energy computations employing Jarzynski identity and Wang – Landau algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalyan, M. Suman, E-mail: maroju.sk@gmail.com; Murthy, K. P. N.; School of Physics, University of Hyderabad, Hyderabad, Telangana, India – 500046

    We introduce a simple method to compute free energy differences employing Jarzynski identity in conjunction with Wang – Landau algorithm. We demonstrate this method on Ising spin system by comparing the results with those obtained from canonical sampling.

  12. The effect of pathological processes on absorption and scattering spectra of samples of bile and pancreatic juice

    NASA Astrophysics Data System (ADS)

    Giraev, K. M.; Ashurbekov, N. A.; Magomedov, M. A.; Murtazaeva, A. A.; Medzhidov, R. T.

    2015-07-01

    Spectra of optical transmission coefficients and optical reflectance for bile and pancreatic juice samples were measured experimentally for different forms of pathologies of the pancreas within the range of 250-2500 nm. The absorption and scattering spectra, as well as the spectrum of the anisotropy factor of scattering, were determined based on the results obtained using the reverse Monte Carlo method. The surface morphology for the corresponding samples of the biological media was studied employing electron microscopy. The dynamics of the optical properties of the biological media was determined depending on the stage of the pathology. It has been demonstrated that the results of the study presented are in a good agreement with pathophysiological data and could supplement and broaden the results of conventional methods for diagnostics of the pancreas.

  13. The relationship between decorrelation time and sample thickness in acute rat brain tissue slices (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Brake, Joshua; Jang, Mooseok; Yang, Changhuei

    2016-03-01

    The optical opacity of biological tissue has long been a challenge in biomedical optics due to the strong scattering nature of tissue in the optical regime. While most conventional optical techniques attempt to gate out multiply scattered light and use only unscattered light, new approaches in the field of wavefront shaping exploit the time reversible symmetry of optical scattering in order to focus light inside or through scattering media. While these approaches have been demonstrated effectively on static samples, it has proven difficult to apply them to dynamic biological samples since even small changes in the relative positions of the scatterers within will cause the time symmetry that wavefront shaping relies upon to decorrelate. In this paper we investigate the decorrelation curves of acute rat brain slices for thicknesses in the range 1-3 mm (1/e decorrelation time on the order of seconds) using multi-speckle diffusing wave spectroscopy (MSDWS) and compare the results with theoretical predictions. The results of this study demonstrate that the 1/L^2 relationship between decorrelation time and thickness predicted by diffusing wave spectroscopy provides a good rule of thumb for estimating how the decorrelation of a sample will change with increasing thickness. Understanding this relationship will provide insight to guide the future development of biophotonic wavefront shaping tools by giving an estimate of how fast wavefront shaping systems need to operate to overcome the dynamic nature of biological samples.

  14. Results of a collaborative study on DNA identification of aged bone samples

    PubMed Central

    Vanek, Daniel; Budowle, Bruce; Dubska-Votrubova, Jitka; Ambers, Angie; Frolik, Jan; Pospisek, Martin; Al Afeefi, Ahmed Anwar; Al Hosani, Khalid Ismaeil; Allen, Marie; Al Naimi, Khudooma Saeed; Al Salafi, Dina; Al Tayyari, Wafa Ali Rashid; Arguetaa, Wendy; Bottinelli, Michel; Bus, Magdalena M.; Cemper-Kiesslich, Jan; Cepil, Olivier; De Cock, Greet; Desmyter, Stijn; El Amri, Hamid; El Ossmani, Hicham; Galdies, Ruth; Grün, Sebastian; Guidet, Francois; Hoefges, Anna; Iancu, Cristian Bogdan; Lotz, Petra; Maresca, Alessandro; Nagy, Marion; Novotny, Jindrich; Rachid, Hajar; Rothe, Jessica; Stenersen, Marguerethe; Stephenson, Mishel; Stevanovitch, Alain; Strien, Juliane; Sumita, Denilce R.; Vella, Joanna; Zander, Judith

    2017-01-01

    Aim A collaborative exercise with several institutes was organized by the Forensic DNA Service (FDNAS) and the Institute of the Legal Medicine, 2nd Faculty of Medicine, Charles University in Prague, Czech Republic, with the aim to test performance of different laboratories carrying out DNA analysis of relatively old bone samples. Methods Eighteen laboratories participating in the collaborative exercise were asked to perform DNA typing of two samples of bone powder. Two bone samples provided by the National Museum and the Institute of Archaelogy in Prague, Czech Republic, came from archeological excavations and were estimated to be approximately 150 and 400 years old. The methods of genetic characterization including autosomal, gonosomal, and mitochondrial markers was selected solely at the discretion of the participating laboratory. Results Although the participating laboratories used different extraction and amplification strategies, concordant results were obtained from the relatively intact 150 years old bone sample. Typing was more problematic with the analysis of the 400 years old bone sample due to poorer quality. Conclusion The laboratories performing identification DNA analysis of bone and teeth samples should regularly test their ability to correctly perform DNA-based identification on bone samples containing degraded DNA and potential inhibitors and demonstrate that risk of contamination is minimized. PMID:28613037

  15. Age determination of bottled Chinese rice wine by VIS-NIR spectroscopy

    NASA Astrophysics Data System (ADS)

    Yu, Haiyan; Lin, Tao; Ying, Yibin; Pan, Xingxiang

    2006-10-01

    The feasibility of non-invasive visible and near infrared (VIS-NIR) spectroscopy for determining wine age (1, 2, 3, 4, and 5 years) of Chinese rice wine was investigated. Samples of Chinese rice wine were analyzed in 600 mL square brown glass bottles with side length of approximately 64 mm at room temperature. VIS-NIR spectra of 100 bottled Chinese rice wine samples were collected in transmission mode in the wavelength range of 350-1200 nm by a fiber spectrometer system. Discriminant models were developed based on discriminant analysis (DA) together with raw, first and second derivative spectra. The concentration of alcoholic degree, total acid, and °Brix was determined to validate the NIR results. The calibration result for raw spectra was better than that for first and second derivative spectra. The percentage of samples correctly classified for raw spectra was 98%. For 1-, 2-, and 3-year-old sample groups, the sample were all correctly classified, and for 4- and 5-year-old sample groups, the percentage of samples correctly classified was 92.9%, respectively. In validation analysis, the percentage of samples correctly classified was 100%. The results demonstrated that VIS-NIR spectroscopic technique could be used as a non-invasive, rapid and reliable method for predicting wine age of bottled Chinese rice wine.

  16. Development and Application of Optical Coherence Elastography for Detection of Mechanical Property Changes Occurring in Early Osteoarthritis

    NASA Astrophysics Data System (ADS)

    Hirota, Koji

    We demonstrate a computationally-efficient method for optical coherence elastography (OCE) based on fringe washout method for a spectral-domain OCT (SD-OCT) system. By sending short pulses of mechanical perturbation with ultrasound or shock wave during the image acquisition of alternating depth profiles, we can extract cross-sectional mechanical assessment of tissue in real-time. This was achieved through a simple comparison of the intensity in adjacent depth profiles acquired during the states of perturbation and non-perturbation in order to quantify the degree of induced fringe washout. Although the results indicate that our OCE technique based on the fringe washout effect is sensitive enough to detect mechanical property changes in biological samples, there is some loss of sensitivity in comparison to previous techniques in order to achieve computationally efficiency and minimum modification in both hardware and software in the OCT system. The tissue phantom study was carried with various agar density samples to characterize our OCE technique. Young's modulus measurements were achieved with the atomic force microscopy (AFM) to correlate to our OCE assessment. Knee cartilage samples of monosodium iodoacetate (MIA) rat models were utilized to replicate cartilage damage of a human model. Our proposed OCE technique along with intensity and AFM measurements were applied to the MIA models to assess the damage. The results from both the phantom study and MIA model study demonstrated the strong capability to assess the changes in mechanical properties of the OCE technique. The correlation between the OCE measurements and the Young's modulus values demonstrated in the OCE data that the stiffer material had less magnitude of fringe washout effect. This result is attributed to the fringe washout effect caused by axial motion that the displacement of the scatterers in the stiffer samples in response to the external perturbation induces less fringe washout effect.

  17. International Space Station (ISS) 3D Printer Performance and Material Characterization Methodology

    NASA Technical Reports Server (NTRS)

    Bean, Q. A.; Cooper, K. G.; Edmunson, J. E.; Johnston, M. M.; Werkheiser, M. J.

    2015-01-01

    In order for human exploration of the Solar System to be sustainable, manufacturing of necessary items on-demand in space or on planetary surfaces will be a requirement. As a first step towards this goal, the 3D Printing In Zero-G (3D Print) technology demonstration made the first items fabricated in space on the International Space Station. From those items, and comparable prints made on the ground, information about the microgravity effects on the printing process can be determined. Lessons learned from this technology demonstration will be applicable to other in-space manufacturing technologies, and may affect the terrestrial manufacturing industry as well. The flight samples were received at the George C. Marshall Space Flight Center on 6 April 2015. These samples will undergo a series of tests designed to not only thoroughly characterize the samples, but to identify microgravity effects manifested during printing by comparing their results to those of samples printed on the ground. Samples will be visually inspected, photographed, scanned with structured light, and analyzed with scanning electron microscopy. Selected samples will be analyzed with computed tomography; some will be assessed using ASTM standard tests. These tests will provide the information required to determine the effects of microgravity on 3D printing in microgravity.

  18. Indentation stiffness does not discriminate between normal and degraded articular cartilage.

    PubMed

    Brown, Cameron P; Crawford, Ross W; Oloyede, Adekunle

    2007-08-01

    Relative indentation characteristics are commonly used for distinguishing between normal healthy and degraded cartilage. The application of this parameter in surgical decision making and an appreciation of articular cartilage biomechanics has prompted us to hypothesise that it is difficult to define a reference stiffness to characterise normal articular cartilage. This hypothesis is tested for validity by carrying out biomechanical indentation of articular cartilage samples that are characterised as visually normal and degraded relative to proteoglycan depletion and collagen disruption. Compressive loading was applied at known strain rates to visually normal, artificially degraded and naturally osteoarthritic articular cartilage and observing the trends of their stress-strain and stiffness characteristics. While our results demonstrated a 25% depreciation in the stiffness of individual samples after proteoglycan depletion, they also showed that when compared to the stiffness of normal samples only 17% lie outside the range of the stress-strain behaviour of normal samples. We conclude that the extent of the variability in the properties of normal samples, and the degree of overlap (81%) of the biomechanical properties of normal and degraded matrices demonstrate that indentation data cannot form an accurate basis for distinguishing normal from abnormal articular cartilage samples with consequences for the application of this mechanical process in the clinical environment.

  19. Control of Rydberg atom blockade by dc electric field orientation in a quasi-one-dimensional sample

    NASA Astrophysics Data System (ADS)

    Goncalves, Luís Felipe; Marcassa, Luis Gustavo

    2017-04-01

    Rydberg atoms posse a strong atom-atom interaction, which limits its density in an atomic sample. Such effect is known as Rydberg atom blockade. Here, we present a novel way to control such effect by direct orienting the induced atomic dipole moment using a dc external electrical field. To demonstrate it, we excite the 50S1 / 2 Rb atomic state in a quasi-one-dimensional sample held in a quasi-electrostatic trap. A pure nS state holds only van der Waals interaction at long range, but in the presence of an external electric field the state mixing leads to strong dipole-dipole interactions. We have measured the Rydberg atom population as a function of ground state atoms density for several angles between the electric field and the main axis of the unidimensional sample. The results indicate that the limit on the final Rydberg density can be controlled by electric field orientation. Besides, we have characterized the sample by using direct spatial ion imaging, demonstrating that it does behave as an unidimensional sample. This work was supported by Sao Paulo Research Foundation (FAPESP) Grants No. 2011/22309-8 and No. 2013/02816- 8, the U.S. Army Research Office Grant No. W911NF-15-1-0638 and CNPq.

  20. Isolation of Coxiella burnetii from serum of patients with acute Q fever.

    PubMed

    Vincent, Gemma A; Graves, Stephen R; Robson, Jennifer M; Nguyen, Chelsea; Hussain-Yusuf, Hazizul; Islam, Aminul; Fenwick, Stanley G; Stenos, John

    2015-12-01

    Worldwide there are few isolate collections of the intracellular bacterium Coxiella burnetii, due to the difficulties associated with working with the organism and the scarcity of suitable samples from which to attempt isolation. Particularly lacking are isolates from acute Q fever patients. The aim of this study was to evaluate whether the serum samples taken from patients with confirmed acute Q fever during the early stage of their disease represented a potential source of viable C. burnetii. Isolation was attempted from 65 of these samples by inoculation of the serum into Vero cell culture and was successful in 36 cases (55%). This high success rate was likely due to extended incubation of up to twelve weeks of the inoculated cultures, allowing the growth of the organism to levels detectable by PCR. Retrospective analysis of the time the sera was stored prior to inoculation into culture demonstrated that C. burnetii remained viable for 224 days in samples stored refrigerated and 371 days in samples stored frozen at -20 °C. These results demonstrate that standard serum samples taken from acute Q fever patients are a valuable source of new isolates of C. burnetii, with no special handling of the specimens required to maintain the organism's viability. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Rapid analysis of controlled substances using desorption electrospray ionization mass spectrometry.

    PubMed

    Rodriguez-Cruz, Sandra E

    2006-01-01

    The recently developed technique of desorption electrospray ionization (DESI) has been applied to the rapid analysis of controlled substances. Experiments have been performed using a commercial ThermoFinnigan LCQ Advantage MAX ion-trap mass spectrometer with limited modifications. Results from the ambient sampling of licit and illicit tablets demonstrate the ability of the DESI technique to detect the main active ingredient(s) or controlled substance(s), even in the presence of other higher-concentration components. Full-scan mass spectrometry data provide preliminary identification by molecular weight determination, while rapid analysis using the tandem mass spectrometry (MS/MS) mode provides fragmentation data which, when compared to the laboratory-generated ESI-MS/MS spectral library, provide structural information and final identification of the active ingredient(s). The consecutive analysis of tablets containing different active components indicates there is no cross-contamination or interference from tablet to tablet, demonstrating the reliability of the DESI technique for rapid sampling (one tablet/min or better). Active ingredients have been detected for tablets in which the active component represents less than 1% of the total tablet weight, demonstrating the sensitivity of the technique. The real-time sampling of cannabis plant material is also presented.

  2. A path integral methodology for obtaining thermodynamic properties of nonadiabatic systems using Gaussian mixture distributions

    NASA Astrophysics Data System (ADS)

    Raymond, Neil; Iouchtchenko, Dmitri; Roy, Pierre-Nicholas; Nooijen, Marcel

    2018-05-01

    We introduce a new path integral Monte Carlo method for investigating nonadiabatic systems in thermal equilibrium and demonstrate an approach to reducing stochastic error. We derive a general path integral expression for the partition function in a product basis of continuous nuclear and discrete electronic degrees of freedom without the use of any mapping schemes. We separate our Hamiltonian into a harmonic portion and a coupling portion; the partition function can then be calculated as the product of a Monte Carlo estimator (of the coupling contribution to the partition function) and a normalization factor (that is evaluated analytically). A Gaussian mixture model is used to evaluate the Monte Carlo estimator in a computationally efficient manner. Using two model systems, we demonstrate our approach to reduce the stochastic error associated with the Monte Carlo estimator. We show that the selection of the harmonic oscillators comprising the sampling distribution directly affects the efficiency of the method. Our results demonstrate that our path integral Monte Carlo method's deviation from exact Trotter calculations is dominated by the choice of the sampling distribution. By improving the sampling distribution, we can drastically reduce the stochastic error leading to lower computational cost.

  3. May 2012 Groundwater and Surface Water Sampling at the Rio Blanco, Colorado, Site (Data Validation Package)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hutton, Rick

    2012-12-01

    Annual sampling was conducted at the Rio Blanco, Colorado, site for the Long-Term Hydrologic Monitoring Program May 9-10, 2012, to monitor groundwater and surface water for potential radionuclide contamination. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for the U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). A duplicate sample was collected from location Johnson Artesian WL. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry and for tritium using the conventional and enrichment methods. Results of this monitoring at the Rio Blanco site demonstrate that groundwater and surface water outsidemore » the site boundaries have not been affected by project-related contaminants.« less

  4. Temperature-dependent phosphorous dopant activation in ZnO thin film deposited using plasma immersion ion implantation

    NASA Astrophysics Data System (ADS)

    Murkute, Punam; Ghadi, Hemant; Saha, Shantanu; Chavan, Vinayak; Chakrabarti, Subhananda

    2018-03-01

    High band gap (3.34 eV) and large exciton binding energy (60 meV) at room temperature facilitates ZnO as a useful candidate for optoelectronics devices. Presence of zinc interstitial and oxygen vacancies results in n-type ZnO film. Phosphorus implantation was carried out using plasma immersion ion implantation technique (2kV, 900W) for constant duration (50 s) on RF sputtered ZnO thin films (Sample A). For dopant activation, sample A was subjected to Rapid Thermal Annealing (RTA) at 700, 800, 900 and 1000°C for 10 s in Oxygen ambient (Sample B, C, D, E). Low temperature (18 K) photoluminescence measurement demonstrated strong donor bound exciton peak for sample A. Dominant donor to acceptor pair peak (DAP) was observed for sample D at around 3.22 eV with linewidth of 131.3 meV. High resolution x-ray diffraction measurement demonstrated (001) and (002) peaks for sample A. (002) peak with high intensity was observed from all annealed samples. Incorporation of phosphorus in ZnO films leads to peak shift towards higher 2θ angle indicate tensile strain in implanted samples. Scanning electron microscopy images reveals improvement in grain size distribution along with reduction of implantation related defects. Raman spectra measured A1(LO) peak at around 576 cm-1 for sample A. Low intensity E2 (high) peak was observed for sample D indicating formation of (PZn+2VZn) complexes. From room temperature Hall measurement, sample D measured 1.17 x 1018 cm -3 carrier concentration with low resistivity of 0.464 Ω.

  5. Microwave Heating of Synthetic Skin Samples for Potential Treatment of Gout Using the Metal-Assisted and Microwave-Accelerated Decrystallization Technique

    PubMed Central

    2016-01-01

    Physical stability of synthetic skin samples during their exposure to microwave heating was investigated to demonstrate the use of the metal-assisted and microwave-accelerated decrystallization (MAMAD) technique for potential biomedical applications. In this regard, optical microscopy and temperature measurements were employed for the qualitative and quantitative assessment of damage to synthetic skin samples during 20 s intermittent microwave heating using a monomode microwave source (at 8 GHz, 2–20 W) up to 120 s. The extent of damage to synthetic skin samples, assessed by the change in the surface area of skin samples, was negligible for microwave power of ≤7 W and more extensive damage (>50%) to skin samples occurred when exposed to >7 W at initial temperature range of 20–39 °C. The initial temperature of synthetic skin samples significantly affected the extent of change in temperature of synthetic skin samples during their exposure to microwave heating. The proof of principle use of the MAMAD technique was demonstrated for the decrystallization of a model biological crystal (l-alanine) placed under synthetic skin samples in the presence of gold nanoparticles. Our results showed that the size (initial size ∼850 μm) of l-alanine crystals can be reduced up to 60% in 120 s without damage to synthetic skin samples using the MAMAD technique. Finite-difference time-domain-based simulations of the electric field distribution of an 8 GHz monomode microwave radiation showed that synthetic skin samples are predicted to absorb ∼92.2% of the microwave radiation. PMID:27917407

  6. Relationship Between LIBS Ablation and Pit Volume for Geologic Samples: Applications for the In Situ Absolute Geochronology

    NASA Technical Reports Server (NTRS)

    Devismes, Damien; Cohen, Barbara; Miller, J.-S.; Gillot, P.-Y.; Lefevre, J.-C.; Boukari, C.

    2014-01-01

    These first results demonstrate that LIBS spectra can be an interesting tool to estimate the ablated volume. When the ablated volume is bigger than 9.10(exp 6) cubic micrometers, this method has less than 10% of uncertainties. Far enough to be directly implemented in the KArLE experiment protocol. Nevertheless, depending on the samples and their mean grain size, the difficulty to have homogeneous spectra will increase with the ablated volume. Several K-Ar dating studies based on this approach will be implemented. After that, the results will be shown and discussed.

  7. Validation of the Short Form of the Academic Procrastination Scale.

    PubMed

    Yockey, Ronald D

    2016-02-01

    The factor structure, internal consistency reliability, and convergent validity of the five-item Academic Procrastination Scale-Short Form was investigated on an ethnically diverse sample of college students. The results provided support for the Academic Procrastination Scale-Short Form as a unidimensional measure of academic procrastination, which possessed good internal consistency reliability in this sample of 282 students. The scale also demonstrated good convergent validity, with moderate to large correlations with both the Procrastination Assessment Scale-Students and the Tuckman Procrastination Scale. Implications of the results are discussed and recommendations for future work provided.

  8. Neutral desorption extractive electrospray ionization mass spectrometry for fast screening sunscreen agents in cream cosmetic products.

    PubMed

    Zhang, Xinglei; Liu, Yan; Zhang, Jinghua; Hu, Zhong; Hu, Bin; Ding, Liying; Jia, Li; Chen, Huanwen

    2011-09-15

    High throughput analysis of sunscreen agents present in cream cosmetic has been demonstrated, typically 2 samples per minute, using neutral desorption extractive electrospray ionization mass spectrometry (ND-EESI-MS) without sample pretreatment. For the targeted compounds such as 4-Aminobenzoic acid and oxybenzone, ND-EESI-MS method provided linear signal responses in the range of 1-100 ppb. Limits of detection (LOD) of the method were estimated at sub-ppb levels for the analytes tested. Reasonable relative standard deviation (RSD=8.4-16.0%) was obtained as a result of 10 independent measurements for commercial cosmetics samples spiked with each individual sunscreen agents at 1-10 ppb. Acceptable recoveries were achieved in the range of 87-116% for direct analysis of commercial cream cosmetic samples. The experimental data demonstrate that ND-EESI-MS is a useful tool for high throughput screening of sunscreen agents in highly viscous cream cosmetic products, with the capability to obtain quantitative information of the analytes. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Inverse supercritical fluid extraction as a sample preparation method for the analysis of the nanoparticle content in sunscreen agents.

    PubMed

    Müller, David; Cattaneo, Stefano; Meier, Florian; Welz, Roland; de Vries, Tjerk; Portugal-Cohen, Meital; Antonio, Diana C; Cascio, Claudia; Calzolai, Luigi; Gilliland, Douglas; de Mello, Andrew

    2016-04-01

    We demonstrate the use of inverse supercritical carbon dioxide (scCO2) extraction as a novel method of sample preparation for the analysis of complex nanoparticle-containing samples, in our case a model sunscreen agent with titanium dioxide nanoparticles. The sample was prepared for analysis in a simplified process using a lab scale supercritical fluid extraction system. The residual material was easily dispersed in an aqueous solution and analyzed by Asymmetrical Flow Field-Flow Fractionation (AF4) hyphenated with UV- and Multi-Angle Light Scattering detection. The obtained results allowed an unambiguous determination of the presence of nanoparticles within the sample, with almost no background from the matrix itself, and showed that the size distribution of the nanoparticles is essentially maintained. These results are especially relevant in view of recently introduced regulatory requirements concerning the labeling of nanoparticle-containing products. The novel sample preparation method is potentially applicable to commercial sunscreens or other emulsion-based cosmetic products and has important ecological advantages over currently used sample preparation techniques involving organic solvents. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Development of Sample Verification System for Sample Return Missions

    NASA Technical Reports Server (NTRS)

    Toda, Risaku; McKinney, Colin; Jackson, Shannon P.; Mojarradi, Mohammad; Trebi-Ollennu, Ashitey; Manohara, Harish

    2011-01-01

    This paper describes the development of a proof of-concept sample verification system (SVS) for in-situ mass measurement of planetary rock and soil sample in future robotic sample return missions. Our proof-of-concept SVS device contains a 10 cm diameter pressure sensitive elastic membrane placed at the bottom of a sample canister. The membrane deforms under the weight of accumulating planetary sample. The membrane is positioned in proximity to an opposing substrate with a narrow gap. The deformation of the membrane makes the gap to be narrower, resulting in increased capacitance between the two nearly parallel plates. Capacitance readout circuitry on a nearby printed circuit board (PCB) transmits data via a low-voltage differential signaling (LVDS) interface. The fabricated SVS proof-of-concept device has successfully demonstrated approximately 1pF/gram capacitance change

  11. [Economic effects of integrated RIS-PACS solution in the university environment].

    PubMed

    Kröger, M; Nissen-Meyer, S; Wetekam, V; Reiser, M

    1999-04-01

    The goal of the current article is to demonstrate how qualitative and monetary effects resulting from an integrated RIS/PACS installation can be evaluated. First of all, the system concept of a RIS/PACS solution for a university hospital is defined and described. Based on this example, a generic method for the evaluation of qualitative and monetary effects as well as associated risks is depicted and demonstrated. To this end, qualitative analyses, investment calculations and risk analysis are employed. The sample analysis of a RIS/PACS solution specially designed for a university hospital demonstrates positive qualitative and monetary effects of the system. Under ideal conditions the payoff time of the investments is reached after 4 years of an assumed 8 years effective life of the system. Furthermore, under conservative assumptions, the risk analysis shows a probability of 0% for realising a negative net present value at the end of the payoff time period. It should be pointed out that the positive result of this sample analysis will not necessarily apply to other clinics or hospitals. However, the same methods may be used for the individual evaluation of the qualitative and monetary effects of a RIS/PACS installation in any clinic.

  12. Time-Lapse Electrical Geophysical Monitoring of Amendment-Based Biostimulation.

    PubMed

    Johnson, Timothy C; Versteeg, Roelof J; Day-Lewis, Frederick D; Major, William; Lane, John W

    2015-01-01

    Biostimulation is increasingly used to accelerate microbial remediation of recalcitrant groundwater contaminants. Effective application of biostimulation requires successful emplacement of amendment in the contaminant target zone. Verification of remediation performance requires postemplacement assessment and contaminant monitoring. Sampling-based approaches are expensive and provide low-density spatial and temporal information. Time-lapse electrical resistivity tomography (ERT) is an effective geophysical method for determining temporal changes in subsurface electrical conductivity. Because remedial amendments and biostimulation-related biogeochemical processes often change subsurface electrical conductivity, ERT can complement and enhance sampling-based approaches for assessing emplacement and monitoring biostimulation-based remediation. Field studies demonstrating the ability of time-lapse ERT to monitor amendment emplacement and behavior were performed during a biostimulation remediation effort conducted at the Department of Defense Reutilization and Marketing Office (DRMO) Yard, in Brandywine, Maryland, United States. Geochemical fluid sampling was used to calibrate a petrophysical relation in order to predict groundwater indicators of amendment distribution. The petrophysical relations were field validated by comparing predictions to sequestered fluid sample results, thus demonstrating the potential of electrical geophysics for quantitative assessment of amendment-related geochemical properties. Crosshole radar zero-offset profile and borehole geophysical logging were also performed to augment the data set and validate interpretation. In addition to delineating amendment transport in the first 10 months after emplacement, the time-lapse ERT results show later changes in bulk electrical properties interpreted as mineral precipitation. Results support the use of more cost-effective surface-based ERT in conjunction with limited field sampling to improve spatial and temporal monitoring of amendment emplacement and remediation performance. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  13. TU-FG-BRB-02: The Impact of Using Dual-Energy CT for Determining Proton Stopping Powers: Comparison Between Theory and Experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baer, E; Jee, K; Zhang, R

    Purpose: To evaluate the clinical performance of dual-energy CT (DECT) in determining proton stopping power ratios (SPR) and demonstrate advantages over conventional single-energy CT (SECT). Methods: SECT and DECT scans of tissue-equivalent plastics as well as animal meat samples are performed with a Siemens SOMATOM Definition Flash. The methods of Schneider et al. (1996) and Bourque et al. (2014) are used to determine proton SPR on SECT and DECT images, respectively. Waterequivalent path length (WEPL) measurements of plastics and tissue samples are performed with a 195 MeV proton beam. WEPL values are determined experimentally using the depth-dose shift and dosemore » extinction methods. Results: Comparison between CT-based and experimental WEPL is performed for 12 tissue-equivalent plastic as well as 6 meat boxes containing animal liver, kidney, heart, stomach, muscle and bones. For plastic materials, results show a systematic improvement in determining SPR with DECT, with a mean absolute error of 0.4% compared to 1.7% for SECT. For the meat samples, preliminary results show the ability for DECT to determine WEPL with a mean absolute value of 1.1% over all meat boxes. Conclusion: This work demonstrates the potential in using DECT for determining proton SPR with plastic materials in a clinical context. Further work is required to show the benefits of DECT for tissue samples. While experimental uncertainties could be a limiting factor to show the benefits of DECT over SECT for the meat samples, further work is required to adapt the DECT formalism in the context of clinical use, where noise and artifacts play an important role.« less

  14. Improvement of DGGE analysis by modifications of PCR protocols for analysis of microbial community members with low abundance.

    PubMed

    Wang, Yong-Feng; Zhang, Fang-Qiu; Gu, Ji-Dong

    2014-06-01

    Denaturing gradient gel electrophoresis (DGGE) is a powerful technique to reveal the community structures and composition of microorganisms in complex natural environments and samples. However, positive and reproducible polymerase chain reaction (PCR) products, which are difficult to acquire for some specific samples due to low abundance of the target microorganisms, significantly impair the effective applications of DGGE. Thus, nested PCR is often introduced to generate positive PCR products from the complex samples, but one problem is also introduced: The total number of thermocycling in nested PCR is usually unacceptably high, which results in skewed community structures by generation of random or mismatched PCR products on the DGGE gel, and this was demonstrated in this study. Furthermore, nested PCR could not resolve the uneven representative issue with PCR products of complex samples with unequal richness of microbial population. In order to solve the two problems in nested PCR, the general protocol was modified and improved in this study. Firstly, a general PCR procedure was used to amplify the target genes with the PCR primers without any guanine cytosine (GC) clamp, and then, the resultant PCR products were purified and diluted to 0.01 μg ml(-1). Subsequently, the diluted PCR products were utilized as templates to amplify again with the same PCR primers with the GC clamp for 17 cycles, and the products were finally subjected to DGGE analysis. We demonstrated that this is a much more reliable approach to obtain a high quality DGGE profile with high reproducibility. Thus, we recommend the adoption of this improved protocol in analyzing microorganisms of low abundance in complex samples when applying the DGGE fingerprinting technique to avoid biased results.

  15. Experimental Evaluation of Preservation Techniques for Benzene, Toluene, Ethylbenzene, and Total Xylenes in Water Samples.

    PubMed

    Arnold, Ray; Kong, Deyuan; Douglas, Gregory; Hardenstine, Jeffery; Rouhani, Shahrokh; Gala, William

    2018-01-01

    An experiment was designed to address the validity of the prescribed maximum allowable holding-time limit of 14 days when acidified at < 2 pH and maintained at 4°C to prevent significant loss of benzene, toluene, ethyl benzene, and xylenes (BTEX) in preserved water samples. Preservation methods prescribed by the United State Environmental Protection Agency were used as well as adaptions of that procedure to determine stability between 3 and 21 days. Water samples preserved at 4°C and pH of < 2 with hydrochloric acid did not result in unacceptable (> 15%) BTEX losses during the study as defined by procedures and statistical methods described by the American Society for Testing and Materials International. In addition, water samples preserved only with acid (pH < 2) at ambient temperatures (20-27°C) also provided acceptable results during the 21-day study. These results have demonstrated the acceptability of BTEX data derived from water samples exceeding the standard holding-time and/or temperature limits.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang Yanxia; Ma He; Peng Nanbo

    We apply one of the lazy learning methods, the k-nearest neighbor (kNN) algorithm, to estimate the photometric redshifts of quasars based on various data sets from the Sloan Digital Sky Survey (SDSS), the UKIRT Infrared Deep Sky Survey (UKIDSS), and the Wide-field Infrared Survey Explorer (WISE; the SDSS sample, the SDSS-UKIDSS sample, the SDSS-WISE sample, and the SDSS-UKIDSS-WISE sample). The influence of the k value and different input patterns on the performance of kNN is discussed. kNN performs best when k is different with a special input pattern for a special data set. The best result belongs to the SDSS-UKIDSS-WISEmore » sample. The experimental results generally show that the more information from more bands, the better performance of photometric redshift estimation with kNN. The results also demonstrate that kNN using multiband data can effectively solve the catastrophic failure of photometric redshift estimation, which is met by many machine learning methods. Compared with the performance of various other methods of estimating the photometric redshifts of quasars, kNN based on KD-Tree shows superiority, exhibiting the best accuracy.« less

  17. Recovery of intrinsic fluorescence from single-point interstitial measurements for quantification of doxorubicin concentration

    PubMed Central

    Baran, Timothy M.; Foster, Thomas H.

    2014-01-01

    Background and Objective We developed a method for the recovery of intrinsic fluorescence from single-point measurements in highly scattering and absorbing samples without a priori knowledge of the sample optical properties. The goal of the study was to demonstrate accurate recovery of fluorophore concentration in samples with widely varying background optical properties, while simultaneously recovering the optical properties. Materials and Methods Tissue-simulating phantoms containing doxorubicin, MnTPPS, and Intralipid-20% were created, and fluorescence measurements were performed using a single isotropic probe. The resulting spectra were analyzed using a forward-adjoint fluorescence model in order to recover the fluorophore concentration and background optical properties. Results We demonstrated recovery of doxorubicin concentration with a mean error of 11.8%. The concentration of the background absorber was recovered with an average error of 23.2% and the scattering spectrum was recovered with a mean error of 19.8%. Conclusion This method will allow for the determination of local concentrations of fluorescent drugs, such as doxorubicin, from minimally invasive fluorescence measurements. This is particularly interesting in the context of transarterial chemoembolization (TACE) treatment of liver cancer. PMID:24037853

  18. Test evaluation of potential heat shield contamination of an Outer Planet Probe's atmospheric sampling system

    NASA Technical Reports Server (NTRS)

    Kessler, W. C.; Woeller, F. H.; Wilkins, M. E.

    1975-01-01

    An Outer Planets Probe which retains the charred heatshield during atmospheric descent must deploy a sampling tube through the heatshield to extract atmospheric samples for analysis. Once the sampling tube is deployed, the atmospheric samples ingested must be free of contaminant gases generated by the heatshield. Outgassing products such as methane and water vapor are present in planetary atmospheres and hence, ingestion of such species would result in gas analyzer measurement uncertainties. This paper evaluates the potential for, and design impact of, the extracted atmospheric samples being contaminated by heatshield outgassing products. Flight trajectory data for Jupiter, Saturn and Uranus entries are analyzed to define the conditions resulting in the greatest potential for outgassing products being ingested into the probe's sampling system. An experimental program is defined and described which simulates the key flow field features for a planetary flight in a ground-based test facility. The primary parameters varied in the test include: sampling tube length, injectant mass flow rate and angle of attack. Measured contaminant levels predict the critical sampling tube length for contamination avoidance. Thus, the study demonstrates the compatibility of a retained heatshield concept and high quality atmospheric trace species measurements.

  19. Development of an NPM1/MLF1 D-FISH probe set for the detection of t(3;5)(q25;q35) identified in patients with acute myeloid leukemia.

    PubMed

    Aypar, Umut; Knudson, Ryan A; Pearce, Kathryn E; Wiktor, Anne E; Ketterling, Rhett P

    2014-09-01

    The t(3;5)(q25;q35) NPM1/MLF1 fusion has an incidence of approximately 0.5% in acute myeloid leukemia (AML) and has an intermediate prognosis at diagnosis. We have developed a dual-color, dual-fusion fluorescence in situ hybridization (D-FISH) assay to detect fusion of the MLF1 and NPM1 genes. A blinded investigation was performed using 25 normal bone marrow specimens and 26 bone marrow samples from patients with one or more metaphases with a t(3;5)(q21-q25;q31-q35) or a der(5)t(3;5)(q21-q25;q31-q35) previously identified by chromosome analysis. Once unblinded, the results indicate our D-FISH method identified NPM1/MLF1 fusion in 15 of the 26 fully evaluated patient samples. Excluding three samples with a single abnormal t(3;5) metaphase, 15 of 17 (88%) patient samples with a balanced t(3;5) demonstrated NPM1/MLF1 fusion, and 0 of 6 patient samples with a der(5)t(3;5) demonstrated NPM1/MLF1 fusion, suggesting only the balanced form of this 3;5 translocation as observed by karyotype is associated with NPM1/MLF1 fusion. Overall, the FISH results demonstrated five different outcomes (NPM1/MLF1 fusion, MLF1 disruption, MLF1 duplication, NPM1 deletion, and normal), indicating significant molecular heterogeneity when the 3;5 translocation is identified. The development of this sensitive D-FISH strategy for the detection of NPM1/MLF1 fusion adds to the AML FISH testing repertoire and is effective in the detection of this translocation at diagnosis as well as monitoring residual disease in AML patients. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  20. Clinical studies of the High-Intensity Narrow-Spectrum light Environmental Decontamination System (HINS-light EDS), for continuous disinfection in the burn unit inpatient and outpatient settings.

    PubMed

    Bache, Sarah E; Maclean, Michelle; MacGregor, Scott J; Anderson, John G; Gettinby, George; Coia, John E; Taggart, Ian

    2012-02-01

    Infections are the leading cause of morbidity and mortality in burn patients and prevention of contamination from exogenous sources including the hospital environment is becoming increasingly emphasised. The High-Intensity Narrow-Spectrum light Environmental Decontamination System (HINS-light EDS) is bactericidal yet safe for humans, allowing continuous disinfection of the environment surrounding burn patients. Environmental samples were collected from inpatient isolation rooms and the outpatient clinic in the burn unit, and comparisons were then made between the bacterial contamination levels observed with and without use of the HINS-light EDS. Over 1000 samples were taken. Inpatient studies, with sampling carried out at 0800 h, demonstrated a significant reduction in the average number of bacterial colonies following HINS-light EDS use of between 27% and 75%, (p<0.05). There was more variation when samples were taken at times of increased activity in the room. Outpatient studies during clinics demonstrated a 61% efficacy in the reduction of bacterial contamination on surfaces throughout the room during the course of a clinic (p=0.02). The results demonstrate that use of the HINS-light EDS allows efficacious bacterial reductions over and above that achieved by standard cleaning and infection control measures in both inpatient and outpatient settings in the burn unit. Copyright © 2011 Elsevier Ltd and ISBI. All rights reserved.

  1. Using Item Response Theory to Develop a 60-Item Representation of the NEO PI-R Using the International Personality Item Pool: Development of the IPIP-NEO-60.

    PubMed

    Maples-Keller, Jessica L; Williamson, Rachel L; Sleep, Chelsea E; Carter, Nathan T; Campbell, W Keith; Miller, Joshua D

    2017-10-31

    Given advantages of freely available and modifiable measures, an increase in the use of measures developed from the International Personality Item Pool (IPIP), including the 300-item representation of the Revised NEO Personality Inventory (NEO PI-R; Costa & McCrae, 1992a ) has occurred. The focus of this study was to use item response theory to develop a 60-item, IPIP-based measure of the Five-Factor Model (FFM) that provides equal representation of the FFM facets and to test the reliability and convergent and criterion validity of this measure compared to the NEO Five Factor Inventory (NEO-FFI). In an undergraduate sample (n = 359), scores from the NEO-FFI and IPIP-NEO-60 demonstrated good reliability and convergent validity with the NEO PI-R and IPIP-NEO-300. Additionally, across criterion variables in the undergraduate sample as well as a community-based sample (n = 757), the NEO-FFI and IPIP-NEO-60 demonstrated similar nomological networks across a wide range of external variables (r ICC = .96). Finally, as expected, in an MTurk sample the IPIP-NEO-60 demonstrated advantages over the Big Five Inventory-2 (Soto & John, 2017 ; n = 342) with regard to the Agreeableness domain content. The results suggest strong reliability and validity of the IPIP-NEO-60 scores.

  2. Integration of reconfigurable potentiometric electrochemical sensors into a digital microfluidic platform.

    PubMed

    Farzbod, Ali; Moon, Hyejin

    2018-05-30

    This paper presents the demonstration of on-chip fabrication of a potassium-selective sensor array enabled by electrowetting on dielectric digital microfluidics for the first time. This demonstration proves the concept that electrochemical sensors can be seamlessly integrated with sample preparation units in a digital microfluidic platform. More significantly, the successful on-chip fabrication of a sensor array indicates that sensors become reconfigurable and have longer lifetime in a digital microfluidic platform. The on-chip fabrication of ion-selective electrodes includes electroplating Ag followed by forming AgCl layer by chemical oxidation and depositing a thin layer of desired polymer-based ion selective membrane on one of the sensor electrodes. In this study, potassium ionophores work as potassium ion channels and make the membrane selective to potassium ions. This selectiveness results in the voltage difference across the membrane layer, which is correlated with potassium ion concentration. The calibration curve of the fabricated potassium-selective electrode demonstrates the slope of 58 mV/dec for potassium concentration in KCl sample solutions and shows good agreement with the ideal Nernstian response. The proposed sensor platform is an outstanding candidate for a portable home-use for continuous monitoring of ions thanks to its advantages such as easy automation of sample preparation and detection processes, elongated sensor lifetime, minimal membrane and sample consumption, and user-definable/reconfigurable sensor array. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Faster protein folding using enhanced conformational sampling of molecular dynamics simulation.

    PubMed

    Kamberaj, Hiqmet

    2018-05-01

    In this study, we applied swarm particle-like molecular dynamics (SPMD) approach to enhance conformational sampling of replica exchange simulations. In particular, the approach showed significant improvement in sampling efficiency of conformational phase space when combined with replica exchange method (REM) in computer simulation of peptide/protein folding. First we introduce the augmented dynamical system of equations, and demonstrate the stability of the algorithm. Then, we illustrate the approach by using different fully atomistic and coarse-grained model systems, comparing them with the standard replica exchange method. In addition, we applied SPMD simulation to calculate the time correlation functions of the transitions in a two dimensional surface to demonstrate the enhancement of transition path sampling. Our results showed that folded structure can be obtained in a shorter simulation time using the new method when compared with non-augmented dynamical system. Typically, in less than 0.5 ns using replica exchange runs assuming that native folded structure is known and within simulation time scale of 40 ns in the case of blind structure prediction. Furthermore, the root mean square deviations from the reference structures were less than 2Å. To demonstrate the performance of new method, we also implemented three simulation protocols using CHARMM software. Comparisons are also performed with standard targeted molecular dynamics simulation method. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. An assessment of the microbiological quality and safety of raw drinking milk on retail sale in England.

    PubMed

    Willis, C; Jørgensen, F; Aird, H; Elviss, N; Fox, A; Jenkins, C; Fenelon, D; Sadler-Reeves, L; McLauchlin, J

    2018-02-01

    This study aimed to review the microbiological results for raw drinking milk (RDM) samples submitted to Public Health England laboratories between 2014 and 2016 in order to produce up-to-date data on the microbiological safety of RDM and inform future risk assessments on its sale. A total of 902 samples of RDM were collected from retail sale in England for microbiological examination. Overall, 454 of 770 samples (59·0%) taken for routine monitoring were of a satisfactory quality, whilst eight (1·0%) were 'unsatisfactory and potentially injurious to health' due to the presence of Shiga toxin-producing Escherichia coli, Campylobacter or elevated levels of Listeria monocytogenes or coagulase-positive staphylococci. In contrast, 16 of 114 (14·0%) of samples taken in follow-up to a previous unsatisfactory result and 5 of 18 (27·8%) of samples related to illness were potentially injurious. A total of 229 of 902 samples (25·4%) gave unsatisfactory results due to elevated aerobic colony counts and/or coliforms, whilst 139 of 902 samples (15·4%) were of borderline quality due to coagulase-positive staphylococci. Listeria monocytogenes was detected at levels of <100 CFU per ml in 66 of 902 samples (7·3%) and other Listeria species in 44 of 902 samples (4·9%). Pathogens and/or indicators of poor hygiene were present in almost half of samples examined. Cows' milk samples gave a significantly greater proportion of unsatisfactory results compared to milk from other species (i.e. goat, sheep, buffalo, camel). These results demonstrate the importance of maintaining strict controls on the production and sale of this product. © 2017 The Society for Applied Microbiology.

  5. Genotyping for DQA1 and PM loci in urine using PCR-based amplification: effects of sample volume, storage temperature, preservatives, and aging on DNA extraction and typing.

    PubMed

    Vu, N T; Chaturvedi, A K; Canfield, D V

    1999-05-31

    Urine is often the sample of choice for drug screening in aviation/general forensic toxicology and in workplace drug testing. In some instances, the origin of the submitted samples may be challenged because of the medicolegal and socioeconomic consequences of a positive drug test. Methods for individualization of biological samples have reached a new boundary with the application of the polymerase chain reaction (PCR) in DNA profiling, but a successful characterization of the urine specimens depends on the quantity and quality of DNA present in the samples. Therefore, the present study investigated the influence of storage conditions, sample volume, concentration modes, extraction procedures, and chemical preservations on the quantity of DNA recovered, as well as the success rate of PCR-based genotyping for DQA1 and PM loci in urine. Urine specimens from male and female volunteers were divided and stored at various temperatures for up to 30 days. The results suggested that sample purification by dialfiltration, using 3000-100,000 molecular weight cut-off filters, did not enhance DNA recovery and typing rate as compared with simple centrifugation procedures. Extraction of urinary DNA by the organic method and by the resin method gave comparable typing results. Larger sample volume yielded a higher amount of DNA, but the typing rates were not affected for sample volumes between 1 and 5 ml. The quantifiable amounts of DNA present were found to be greater in female (14-200 ng/ml) than in male (4-60 ng/ml) samples and decreased with the elapsed time under both room temperature (RT) and frozen storage. Typing of the male samples also demonstrated that RT storage samples produced significantly higher success rates than that of frozen samples, while there was only marginal difference in the DNA typing rates among the conditions tested using female samples. Successful assignment of DQA1 + PM genotype was achieved for all samples of fresh urine, independent of gender, starting sample volume, or concentration method. Preservation by 0.25% sodium azide was acceptable for sample storage at 4 degrees C during a period of 30 days. For longer storage duration, freezing at -70 degrees C may be more appropriate. Thus, the applicability of the DQA1 + PM typing was clearly demonstrated for individualization of urine samples.

  6. Propionibacterium acnes Recovered from Atherosclerotic Human Carotid Arteries Undergoes Biofilm Dispersion and Releases Lipolytic and Proteolytic Enzymes in Response to Norepinephrine Challenge In Vitro

    PubMed Central

    Lanter, Bernard B.

    2015-01-01

    In the present study, human atherosclerotic carotid arteries were examined following endarterectomy for the presence of the Gram-positive bacterium Propionibacterium acnes and its potential association with biofilm structures within the arterial wall. The P. acnes 16S rRNA gene was detectable in 4 of 15 carotid artery samples, and viable P. acnes was one among 10 different bacterial species recoverable in culture. Fluorescence in situ hybridization analysis of 5 additional atherosclerotic carotid arteries demonstrated biofilm bacteria within all samples, with P. acnes detectable in 4 samples. We also demonstrated that laboratory-grown cultures of P. acnes biofilms were susceptible to induction of a biofilm dispersion response when challenged with physiologically relevant levels of norepinephrine in the presence of iron-bound transferrin or with free iron. The production and release of lipolytic and proteolytic extracellular enzymes by P. acnes were shown to increase in iron-induced dispersed biofilms, and these dispersion-induced P. acnes VP1 biofilms showed increased expression of mRNAs for the triacylglycerol lipases PPA2105 and PPA1796 and the hyaluronate lyase PPA380 compared to that in untreated biofilms. These results demonstrate that P. acnes can infect the carotid arteries of humans with atherosclerosis as a component of multispecies biofilms and that dispersion is inducible for this organism, at least in vitro, with physiologically relevant levels of norepinephrine resulting in the production and release of degradative enzymes. PMID:26216428

  7. Standoff detection of chemical and biological threats using laser-induced breakdown spectroscopy.

    PubMed

    Gottfried, Jennifer L; De Lucia, Frank C; Munson, Chase A; Miziolek, Andrzej W

    2008-04-01

    Laser-induced breakdown spectroscopy (LIBS) is a promising technique for real-time chemical and biological warfare agent detection in the field. We have demonstrated the detection and discrimination of the biological warfare agent surrogates Bacillus subtilis (BG) (2% false negatives, 0% false positives) and ovalbumin (0% false negatives, 1% false positives) at 20 meters using standoff laser-induced breakdown spectroscopy (ST-LIBS) and linear correlation. Unknown interferent samples (not included in the model), samples on different substrates, and mixtures of BG and Arizona road dust have been classified with reasonable success using partial least squares discriminant analysis (PLS-DA). A few of the samples tested such as the soot (not included in the model) and the 25% BG:75% dust mixture resulted in a significant number of false positives or false negatives, respectively. Our preliminary results indicate that while LIBS is able to discriminate biomaterials with similar elemental compositions at standoff distances based on differences in key intensity ratios, further work is needed to reduce the number of false positives/negatives by refining the PLS-DA model to include a sufficient range of material classes and carefully selecting a detection threshold. In addition, we have demonstrated that LIBS can distinguish five different organophosphate nerve agent simulants at 20 meters, despite their similar stoichiometric formulas. Finally, a combined PLS-DA model for chemical, biological, and explosives detection using a single ST-LIBS sensor has been developed in order to demonstrate the potential of standoff LIBS for universal hazardous materials detection.

  8. Human exposure to mercury in a compact fluorescent lamp manufacturing area: By food (rice and fish) consumption and occupational exposure.

    PubMed

    Liang, Peng; Feng, Xinbin; Zhang, Chan; Zhang, Jin; Cao, Yucheng; You, Qiongzhi; Leung, Anna Oi Wah; Wong, Ming-Hung; Wu, Sheng-Chun

    2015-03-01

    To investigate human Hg exposure by food consumption and occupation exposure in a compact fluorescent lamp (CFL) manufacturing area, human hair and rice samples were collected from Gaohong town, Zhejiang Province, China. The mean values of total mercury (THg) and methylmercury (MeHg) concentrations in local cultivated rice samples were significantly higher than in commercial rice samples which indicated that CFL manufacturing activities resulted in Hg accumulation in local rice samples. For all of the study participants, significantly higher THg concentrations in human hair were observed in CFL workers compared with other residents. In comparison, MeHg concentrations in human hair of residents whose diet consisted of local cultivated rice were significantly higher than those who consumed commercial rice. These results demonstrated that CFL manufacturing activities resulted in THg accumulation in the hair of CFL workers. However, MeHg in hair were mainly affected by the sources of rice of the residents. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Solid-state characterization and impurities determination of fluconazol generic products marketed in Morocco

    PubMed Central

    Bourichi, Houda; Brik, Youness; Hubert, Philipe; Cherrah, Yahia; Bouklouze, Abdelaziz

    2012-01-01

    In this paper, we report the results of quality control based in physicochemical characterization and impurities determination of three samples of fluconazole drug substances marketed in Morocco. These samples were supplied by different pharmaceuticals companies. The sample A, as the discovered product, was supplied by Pfizer, while samples B and C (generics), were manufactured by two different Indian industries. Solid-state characterization of the three samples was realized with different physicochemical methods as: X-ray powder diffraction, Fourier-transformation infrared spectroscopy, differential scanning calorimetry. High performance liquid chromatography was used to quantify the impurities in the different samples. The results from the physicochemical methods cited above, showed difference in polymorph structure of the three drug substances. Sample A consisted in pure polymorph III, sample B consisted in pure polymorph II, sample C consisted in a mixture of fluconazole Form III, form II and the monohydrate. This result was confirmed by differential scanning calorimetry. Also it was demonstrated that solvents used during the re-crystallization step were among the origins of these differences in the structure form. On the other hand, the result of the stability study under humidity and temperature showed that fluconazole polymorphic transformation could be owed to the no compliance with the conditions of storage. The HPLC analysis of these compounds showed the presence of specific impurities for each polymorphic form, and a possible relationship could be exist between impurities and crystalline form of fluconazole. PMID:29403776

  10. Enhancing sampling design in mist-net bat surveys by accounting for sample size optimization.

    PubMed

    Trevelin, Leonardo Carreira; Novaes, Roberto Leonan Morim; Colas-Rosas, Paul François; Benathar, Thayse Cristhina Melo; Peres, Carlos A

    2017-01-01

    The advantages of mist-netting, the main technique used in Neotropical bat community studies to date, include logistical implementation, standardization and sampling representativeness. Nonetheless, study designs still have to deal with issues of detectability related to how different species behave and use the environment. Yet there is considerable sampling heterogeneity across available studies in the literature. Here, we approach the problem of sample size optimization. We evaluated the common sense hypothesis that the first six hours comprise the period of peak night activity for several species, thereby resulting in a representative sample for the whole night. To this end, we combined re-sampling techniques, species accumulation curves, threshold analysis, and community concordance of species compositional data, and applied them to datasets of three different Neotropical biomes (Amazonia, Atlantic Forest and Cerrado). We show that the strategy of restricting sampling to only six hours of the night frequently results in incomplete sampling representation of the entire bat community investigated. From a quantitative standpoint, results corroborated the existence of a major Sample Area effect in all datasets, although for the Amazonia dataset the six-hour strategy was significantly less species-rich after extrapolation, and for the Cerrado dataset it was more efficient. From the qualitative standpoint, however, results demonstrated that, for all three datasets, the identity of species that are effectively sampled will be inherently impacted by choices of sub-sampling schedule. We also propose an alternative six-hour sampling strategy (at the beginning and the end of a sample night) which performed better when resampling Amazonian and Atlantic Forest datasets on bat assemblages. Given the observed magnitude of our results, we propose that sample representativeness has to be carefully weighed against study objectives, and recommend that the trade-off between logistical constraints and additional sampling performance should be carefully evaluated.

  11. Enhancing sampling design in mist-net bat surveys by accounting for sample size optimization

    PubMed Central

    Trevelin, Leonardo Carreira; Novaes, Roberto Leonan Morim; Colas-Rosas, Paul François; Benathar, Thayse Cristhina Melo; Peres, Carlos A.

    2017-01-01

    The advantages of mist-netting, the main technique used in Neotropical bat community studies to date, include logistical implementation, standardization and sampling representativeness. Nonetheless, study designs still have to deal with issues of detectability related to how different species behave and use the environment. Yet there is considerable sampling heterogeneity across available studies in the literature. Here, we approach the problem of sample size optimization. We evaluated the common sense hypothesis that the first six hours comprise the period of peak night activity for several species, thereby resulting in a representative sample for the whole night. To this end, we combined re-sampling techniques, species accumulation curves, threshold analysis, and community concordance of species compositional data, and applied them to datasets of three different Neotropical biomes (Amazonia, Atlantic Forest and Cerrado). We show that the strategy of restricting sampling to only six hours of the night frequently results in incomplete sampling representation of the entire bat community investigated. From a quantitative standpoint, results corroborated the existence of a major Sample Area effect in all datasets, although for the Amazonia dataset the six-hour strategy was significantly less species-rich after extrapolation, and for the Cerrado dataset it was more efficient. From the qualitative standpoint, however, results demonstrated that, for all three datasets, the identity of species that are effectively sampled will be inherently impacted by choices of sub-sampling schedule. We also propose an alternative six-hour sampling strategy (at the beginning and the end of a sample night) which performed better when resampling Amazonian and Atlantic Forest datasets on bat assemblages. Given the observed magnitude of our results, we propose that sample representativeness has to be carefully weighed against study objectives, and recommend that the trade-off between logistical constraints and additional sampling performance should be carefully evaluated. PMID:28334046

  12. Comparative performance of contact plates, electrostatic wipes, swabs and a novel sampling device for the detection of Staphylococcus aureus on environmental surfaces.

    PubMed

    Lutz, J K; Crawford, J; Hoet, A E; Wilkins, J R; Lee, J

    2013-07-01

    To evaluate the performance of four sampling methods [contact plates, electrostatic wipes (wipe), swabs and a novel roller sampler] for recovery of Staphylococcus aureus from a stainless steel surface. Stainless steel test plates were inoculated with Staph. aureus, dried for 24 h and sampled using each of the four methods. Samples were either incubated directly (roller, contact plate) or processed using elution and membrane filtration (swab, wipe). Performance was assessed by calculating the apparent sampling efficiency (ASE), analytical sensitivity (Sn) and percentage of replications with positive growth. The wipe demonstrated the best performance across all inoculating concentrations (ASE(48 h) = 18%; Sn(48 h) = 7 CFU per 100 cm(2)). The swab performed well when corrected for area actually sampled (ASE(48 h) = 24%; Sn(48 h) = 76 CFU per 100 cm(2)). Of the contact-based methods, the newly developed roller sampler outperformed the contact plate (roller: ASE(48 h) = 10%; Sn(48 h) = 17 CFU per 100 cm(2); contact plate: ASE(48 h) = 0·04%; Sn(48 h) = 1412 CFU per 100 cm(2)); both contact samplers performed better at higher inoculating concentrations (6E3 CFU per 100 cm(2) for the roller and 6E6 CFU per 100 cm(2) for the contact plate). Overall, the electrostatic wipe produced the highest number of replications resulting in positive growth (74%(24 h), 91%(48 h)). This study demonstrates that selection of the sampling method must be carefully considered, given that different methods have varying performance. This is the first study assessing static wipes for sampling and one that uses a more real-world-relevant 24-h drying time. The results help with infection control, and environmental health professionals choose better sampling methodologies. Journal of Applied Microbiology © 2013 The Society for Applied Microbiology.

  13. Detection of antileishmanial antibodies in blood sampled from blood bank donors in Istanbul.

    PubMed

    Ates, Sezen Canim; Bagirova, Malahat; Allahverdiyev, Adil M; Baydar, Serap Yesilkir; Koc, Rabia Cakir; Elcicek, Serhat; Abamor, Emrah Sefik; Oztel, Olga Nehir

    2012-06-01

    According to the WHO, only 5-20% of the total cases of leishmaniasis are symptomatic leishmaniasis; the other cases are identified as asymptomatic leishmaniasis. In recent studies, it has been demonstrated that donor blood plays an important role in the epidemiology of asymptomatic leishmaniasis. However, the number of the studies on this subject is still insufficient. Additionally, donor blood samples obtained from Istanbul, which is the biggest metropolitan area in Turkey, have not been investigated with regard to Leishmania. Moreover, there is no information about the sensitivity of noninvasive serological methods that are used in the detection of leishmaniasis donor blood samples. Accordingly, this study aimed to investigate the presence of antileishmanial antibodies in blood samples obtained from blood bank donors in Istanbul, by using different serologic methods, and to determine the most sensitive detection method. Blood samples were taken from 188 healthy blood bank donors to the Capa Turkish Red Crescent Blood Bank (Istanbul, Turkey), and the presence of antileishmanial antibodies was measured by indirect immunofluorescent antibody test (IFAT), ELISA, immunochromatographic dipstick rapid test, and western blot (WB). Antileishmanial antibodies were determined in 12 out of 188 samples by IFAT (6.4%), and six out of these 12 donors were found to be positive at diagnostic titer 1:128 (3.2%). One hundred and eighty eight samples were investigated by ELISA and one (0.5%) of them gave a positive result. None of 188 samples provided a positive result by immunochromatographic test. WB applied to the 12 seroreactive donors showed that three out of 12 donors were positive. In this study, the presence of antileishmanial antibodies in blood samples of blood bank donors from Istanbul has been demonstrated by using feasible and low-cost serological methods. Additionally, in comparison with other simple and low-cost detection methods, WB was used for confirmation. IFAT has a higher sensitivity and therefore may be preferred as a prescreening method in endemic or nonendemic areas.

  14. In-Situ Propellant Production on Mars: A Sabatier/Electrolysis Demonstration Plant

    NASA Astrophysics Data System (ADS)

    Clark, David L.

    1997-01-01

    An efficient, reliable propellant production plant has been developed for use on Mars. Using a Sabatier reactor in conjunction with a water electrolysis system, a complete demonstration plant has produced methane and liquid oxygen from simulated Martian atmosphere. The production plant has demonstrated high efficiency, extended duration production and autonomous operations. This paper presents the results and conclusions relating to eventual use in a Mars sample return mission. This work was funded by the Jet Propulsion Laboratory (JPL). The production plant was built and tested at the Propulsion Center of Lockheed Martin at the Denver Colorado facility.

  15. Reduced Sampling Size with Nanopipette for Tapping-Mode Scanning Probe Electrospray Ionization Mass Spectrometry Imaging

    PubMed Central

    Kohigashi, Tsuyoshi; Otsuka, Yoichi; Shimazu, Ryo; Matsumoto, Takuya; Iwata, Futoshi; Kawasaki, Hideya; Arakawa, Ryuichi

    2016-01-01

    Mass spectrometry imaging (MSI) with ambient sampling and ionization can rapidly and easily capture the distribution of chemical components in a solid sample. Because the spatial resolution of MSI is limited by the size of the sampling area, reducing sampling size is an important goal for high resolution MSI. Here, we report the first use of a nanopipette for sampling and ionization by tapping-mode scanning probe electrospray ionization (t-SPESI). The spot size of the sampling area of a dye molecular film on a glass substrate was decreased to 6 μm on average by using a nanopipette. On the other hand, ionization efficiency increased with decreasing solvent flow rate. Our results indicate the compatibility between a reduced sampling area and the ionization efficiency using a nanopipette. MSI of micropatterns of ink on a glass and a polymer substrate were also demonstrated. PMID:28101441

  16. In vivo microsampling to capture the elusive exposome

    NASA Astrophysics Data System (ADS)

    Bessonneau, Vincent; Ings, Jennifer; McMaster, Mark; Smith, Richard; Bragg, Leslie; Servos, Mark; Pawliszyn, Janusz

    2017-03-01

    Loss and/or degradation of small molecules during sampling, sample transportation and storage can adversely impact biological interpretation of metabolomics data. In this study, we performed in vivo sampling using solid-phase microextraction (SPME) in combination with non-targeted liquid chromatography and high-resolution tandem mass spectrometry (LC-MS/MS) to capture the fish tissue exposome using molecular networking analysis, and the results were contrasted with molecular differences obtained with ex vivo SPME sampling. Based on 494 MS/MS spectra comparisons, we demonstrated that in vivo SPME sampling provided better extraction and stabilization of highly reactive molecules, such as 1-oleoyl-sn-glycero-3-phosphocholine and 1-palmitoleoyl-glycero-3-phosphocholine, from fish tissue samples. This sampling approach, that minimizes sample handling and preparation, offers the opportunity to perform longitudinal monitoring of the exposome in biological systems and improve the reliability of exposure-measurement in exposome-wide association studies.

  17. In vivo microsampling to capture the elusive exposome

    PubMed Central

    Bessonneau, Vincent; Ings, Jennifer; McMaster, Mark; Smith, Richard; Bragg, Leslie; Servos, Mark; Pawliszyn, Janusz

    2017-01-01

    Loss and/or degradation of small molecules during sampling, sample transportation and storage can adversely impact biological interpretation of metabolomics data. In this study, we performed in vivo sampling using solid-phase microextraction (SPME) in combination with non-targeted liquid chromatography and high-resolution tandem mass spectrometry (LC-MS/MS) to capture the fish tissue exposome using molecular networking analysis, and the results were contrasted with molecular differences obtained with ex vivo SPME sampling. Based on 494 MS/MS spectra comparisons, we demonstrated that in vivo SPME sampling provided better extraction and stabilization of highly reactive molecules, such as 1-oleoyl-sn-glycero-3-phosphocholine and 1-palmitoleoyl-glycero-3-phosphocholine, from fish tissue samples. This sampling approach, that minimizes sample handling and preparation, offers the opportunity to perform longitudinal monitoring of the exposome in biological systems and improve the reliability of exposure-measurement in exposome-wide association studies. PMID:28266605

  18. Open Probe fast GC-MS - combining ambient sampling ultra-fast separation and in-vacuum ionization for real-time analysis.

    PubMed

    Keshet, U; Alon, T; Fialkov, A B; Amirav, A

    2017-07-01

    An Open Probe inlet was combined with a low thermal mass ultra-fast gas chromatograph (GC), in-vacuum electron ionization ion source and a mass spectrometer (MS) of GC-MS for obtaining real-time analysis with separation. The Open Probe enables ambient sampling via sample vaporization in an oven that is open to room air, and the ultra-fast GC provides ~30-s separation, while if no separation is required, it can act as a transfer line with 2 to 3-s sample transfer time. Sample analysis is as simple as touching the sample, pushing the sample holder into the Open Probe oven and obtaining the results in 30 s. The Open Probe fast GC was mounted on a standard Agilent 7890 GC that was coupled with an Agilent 5977A MS. Open Probe fast GC-MS provides real-time analysis combined with GC separation and library identification, and it uses the low-cost MS of GC-MS. The operation of Open Probe fast GC-MS is demonstrated in the 30-s separation and 50-s full analysis cycle time of tetrahydrocannabinol and cannabinol in Cannabis flower, sub 1-min analysis of trace trinitrotoluene transferred from a finger onto a glass surface, vitamin E in canola oil, sterols in olive oil, polybrominated flame retardants in plastics, alprazolam in Xanax drug pill and free fatty acids and cholesterol in human blood. The extrapolated limit of detection for pyrene is <1 fg, but the concentration is too high and the software noise calculation is untrustworthy. The broad range of compounds amenable for analysis is demonstrated in the analysis of reserpine. The possible use with alternate standard GC-MS and Open Probe fast GC-MS is demonstrated in the analysis of heroin in its street drug powder. The use of Open Probe with the fast GC acting as a transfer line is demonstrated in <10-s analysis without separation of ibuprofen and estradiol. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Model-based frequency response characterization of a digital-image analysis system for epifluorescence microscopy

    NASA Technical Reports Server (NTRS)

    Hazra, Rajeeb; Viles, Charles L.; Park, Stephen K.; Reichenbach, Stephen E.; Sieracki, Michael E.

    1992-01-01

    Consideration is given to a model-based method for estimating the spatial frequency response of a digital-imaging system (e.g., a CCD camera) that is modeled as a linear, shift-invariant image acquisition subsystem that is cascaded with a linear, shift-variant sampling subsystem. The method characterizes the 2D frequency response of the image acquisition subsystem to beyond the Nyquist frequency by accounting explicitly for insufficient sampling and the sample-scene phase. Results for simulated systems and a real CCD-based epifluorescence microscopy system are presented to demonstrate the accuracy of the method.

  20. Three Microstructural Exercises for Students.

    ERIC Educational Resources Information Center

    Means, Winthrop D.

    1986-01-01

    Describes laboratory exercises which demonstrate a new simplified technique for deforming thin samples of crystalline materials on the stage of a petrographic microscope. Discusses how this process allows students to see the development of microstructures resulting from cracking, slipping, thinning, and recrystallization. References and sources of…

  1. Cross-Validation of the Africentrism Scale.

    ERIC Educational Resources Information Center

    Kwate, Naa Oyo A.

    2003-01-01

    Cross-validated the Africentrism Scale, investigating the relationship between Africentrism and demographic variables in a diverse sample of individuals of African descent. Results indicated that the scale demonstrated solid internal consistency and convergent validity. Age and education related to Africentrism, with younger and less educated…

  2. Multi-Scale/Multi-Functional Probabilistic Composite Fatigue

    NASA Technical Reports Server (NTRS)

    Chamis, Christos C.

    2008-01-01

    A multi-level (multi-scale/multi-functional) evaluation is demonstrated by applying it to three different sample problems. These problems include the probabilistic evaluation of a space shuttle main engine blade, an engine rotor and an aircraft wing. The results demonstrate that the blade will fail at the highest probability path, the engine two-stage rotor will fail by fracture at the rim and the aircraft wing will fail at 109 fatigue cycles with a probability of 0.9967.

  3. Precision Timing Calorimeter for High Energy Physics

    DOE PAGES

    Anderson, Dustin; Apresyan, Artur; Bornheim, Adolf; ...

    2016-04-01

    Here, we present studies on the performance and characterization of the time resolution of LYSO-based calorimeters. Results for an LYSO sampling calorimeter and an LYSO-tungsten Shashlik calorimeter are presented. We also demonstrate that a time resolution of 30 ps is achievable for the LYSO sampling calorimeter. Timing calorimetry is described as a tool for mitigating the effects due to the large number of simultaneous interactions in the high luminosity environment foreseen for the Large Hadron Collider.

  4. Observation of NMR noise from solid samples.

    PubMed

    Schlagnitweit, Judith; Dumez, Jean-Nicolas; Nausner, Martin; Jerschow, Alexej; Elena-Herrmann, Bénédicte; Müller, Norbert

    2010-11-01

    We demonstrate that proton NMR noise signals, i.e. NMR spectra without excitation by radio frequency, can be obtained from solid samples. Experimental results are shown for static and magic-angle spinning conditions. In addition, a tuning procedure based on the probes' NMR noise characteristics and similar to the one described previously for liquids probes can also be used to optimize signal-to-noise ratios in ¹H-MAS experiments. Copyright © 2010 Elsevier Inc. All rights reserved.

  5. Identifying the Experimental and Theoretical Effective Characteristics of Nonaligned Anisotropic Metamaterials

    DTIC Science & Technology

    2015-06-18

    nanorods, while the second demonstrated long and skinny nanorods. This is demosntrated in Figure 20. The University of Dayton research group asked Dr...here and in other research carried out with this methodology. 5.4 Simulations 5.4.1 Experimental results. All of the simulations carried out in this...samples that Dr. Sarangan and Dr. Shah of the University of Dayton presented to Dr. Marciniak’s research group . The samples consisted of silver tilted

  6. ENVIRONMENTAL EVALUATION FOR UTILIZATION OF ASH IN SOIL STABILIZATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    David J. Hassett; Loreal V. Heebink

    2001-08-01

    The Minnesota Pollution Control Agency (MPCA) approved the use of coal ash in soil stabilization, indicating that environmental data needed to be generated. The overall project goal is to evaluate the potential for release of constituents into the environment from ash used in soil stabilization projects. Supporting objectives are: (1) To ensure sample integrity through implementation of a sample collection, preservation, and storage protocol to avoid analyte concentration or loss. (2) To evaluate the potential of each component (ash, soil, water) of the stabilized soil to contribute to environmental release of analytes of interest. (3) To use laboratory leaching methodsmore » to evaluate the potential for release of constituents to the environment. (4) To facilitate collection of and to evaluate samples from a field runoff demonstration effort. The results of this study indicated limited mobility of the coal combustion fly ash constituents in laboratory tests and the field runoff samples. The results presented support previous work showing little to negligible impact on water quality. This and past work indicates that soil stabilization is an environmentally beneficial CCB utilization application as encouraged by the U.S. Environmental Protection Agency. This project addressed the regulatory-driven environmental aspect of fly ash use for soil stabilization, but the demonstrated engineering performance and economic advantages also indicate that the use of CCBs in soil stabilization can and should become an accepted engineering option.« less

  7. Intensive care unit environmental surfaces are contaminated by multidrug-resistant bacteria in biofilms: combined results of conventional culture, pyrosequencing, scanning electron microscopy, and confocal laser microscopy.

    PubMed

    Hu, H; Johani, K; Gosbell, I B; Jacombs, A S W; Almatroudi, A; Whiteley, G S; Deva, A K; Jensen, S; Vickery, K

    2015-09-01

    Hospital-associated infections cause considerable morbidity and mortality, and are expensive to treat. Organisms causing these infections can be sourced from the inanimate environment around a patient. Could the difficulty in eradicating these organisms from the environment be because they reside in dry surface biofilms? The intensive care unit (ICU) of a tertiary referral hospital was decommissioned and the opportunity to destructively sample clinical surfaces was taken in order to investigate whether multidrug-resistant organisms (MDROs) had survived the decommissioning process and whether they were present in biofilms. The ICU had two 'terminal cleans' with 500 ppm free chlorine solution; items from bedding, surrounds, and furnishings were then sampled with cutting implements. Sections were sonicated in tryptone soya broth and inoculated on to chromogenic plates to demonstrate MDROs, which were confirmed with the Vitek2 system. Genomic DNA was extracted directly from ICU samples, and subjected to polymerase chain reaction (PCR) for femA to detect Staphylococcus aureus and the microbiome by bacterial tag-encoded FLX amplicon pyrosequencing. Confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM) were performed on environmental samples. Multidrug-resistant bacteria were cultured from 52% (23/44) of samples cultured. S. aureus PCR was positive in 50%. Biofilm was demonstrated in 93% (41/44) of samples by CLSM and/or SEM. Pyrosequencing demonstrated that the biofilms were polymicrobial and contained species that had multidrug-resistant strains. Dry surface biofilms containing MDROs are found on ICU surfaces despite terminal cleaning with chlorine solution. How these arise and how they might be removed requires further study. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  8. Development of solid materials for UF 6 sampling: FY16 Annual Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Nicholas; Savina, Joseph; Hebden, Andrew

    2016-10-31

    A handheld implementation of the ABACC-developed Cristallini method, which captures uranium hexafluoride samples as an inert salt, was organized in FY17 and succeeded in demonstrating the handheld sampler concept with reactive hexafluoride gases. The Cristallini method relies on the use of a hydrated substrate to react the incoming hexafluoride resulting in the formation of a stable uranyl fluoride salt. The Cristallini method has been demonstrated as a facility modification installed near the sampling tap of a gas centrifuge enrichment plant. While very successful in reducing the hazards of uranium hexafluoride sample, the method still takes a considerable amount of timemore » and can only be used in facilities where the apparatus has been installed; this arrangement generally prohibits the sampling of filled cylinders that have already exited the facility and have been deposited in the on-site tank storage yard. The handheld unit under development will allow the use of the Cristallini method at facilities that have not been converted as well as tanks in the storage yard. The handheld system utilizes an active vacuum system, rather than a passive vacuum system in the facility setup, to drive the uranium hexafluoride onto the adsorbing media. The handheld unit will be battery operated for fully autonomous operation and will include onboard pressure sensing and flushing capability. To date, the system concept of operations was demonstrated with tungsten hexafluoride that showed the active vacuum pump with multiple cartridges of adsorbing media was viable. Concurrently, the hardened prototype system was developed and tested; removable sample cartridges were developed (the only non-COTS component to date); and preparations were made for uranium tests and a domestic field test.« less

  9. Determination of Inorganic Ion Profiles of Illicit Drugs by Capillary Electrophoresis.

    PubMed

    Evans, Elizabeth; Costrino, Carolina; do Lago, Claudimir L; Garcia, Carlos D; Roux, Claude; Blanes, Lucas

    2016-11-01

    A portable capillary electrophoresis instrument with dual capacitively coupled contactless conductivity detection (C 4 D) was used to determine the inorganic ionic profiles of three pharmaceutical samples and precursors of two illicit drugs (contemporary samples of methylone and para-methoxymethamphetamine). The LODs ranged from 0.10 μmol/L to 1.25 μmol/L for the 10 selected cations, and from 0.13 μmol/L to 1.03 μmol/L for the eight selected anions. All separations were performed in less than 6 min with migration times and peak area RSD values ranging from 2 to 7%. The results demonstrate the potential of the analysis of inorganic ionic species to aid in the identification and/or differentiation of unknown tablets, and real samples found in illicit drug manufacture scenarios. From the resulting ionic fingerprint, the unknown tablets and samples can be further classified. © 2016 American Academy of Forensic Sciences.

  10. Sample size in psychological research over the past 30 years.

    PubMed

    Marszalek, Jacob M; Barber, Carolyn; Kohlhart, Julie; Holmes, Cooper B

    2011-04-01

    The American Psychological Association (APA) Task Force on Statistical Inference was formed in 1996 in response to a growing body of research demonstrating methodological issues that threatened the credibility of psychological research, and made recommendations to address them. One issue was the small, even dramatically inadequate, size of samples used in studies published by leading journals. The present study assessed the progress made since the Task Force's final report in 1999. Sample sizes reported in four leading APA journals in 1955, 1977, 1995, and 2006 were compared using nonparametric statistics, while data from the last two waves were fit to a hierarchical generalized linear growth model for more in-depth analysis. Overall, results indicate that the recommendations for increasing sample sizes have not been integrated in core psychological research, although results slightly vary by field. This and other implications are discussed in the context of current methodological critique and practice.

  11. Nipah Virus in Lyle's Flying Foxes, Cambodia

    PubMed Central

    Counor, Dorian; Ong, Sivuth; Faure, Caroline; Seng, Vansay; Molia, Sophie; Walston, Joe; Georges-Courbot, Marie Claude; Deubel, Vincent; Sarthou, Jean-Louis

    2005-01-01

    We conducted a survey in Cambodia in 2000 on henipavirus infection among several bat species, including flying foxes, and persons exposed to these animals. Among 1,072 bat serum samples tested by enzyme-linked immunosorbent assay, antibodies reactive to Nipah virus (NiV) antigen were detected only in Pteropus lylei species; Cynopterus sphinx, Hipposideros larvatus, Scotophilus kuhlii, Chaerephon plicata, Taphozous melanopogon, and T. theobaldi species were negative. Seroneutralization applied on a subset of 156 serum samples confirmed these results. None of the 8 human serum samples was NiV seropositive with the seroneutralization test. One virus isolate exhibiting cytopathic effect with syncytia was obtained from 769 urine samples collected at roosts of P. lylei specimens. Partial molecular characterization of this isolate demonstrated that it was closely related to NiV. These results strengthen the hypothesis that flying foxes could be the natural host of NiV. Surveillance of human cases should be implemented. PMID:16022778

  12. Determination of sulphite in wine by coulometric titration.

    PubMed

    Lowinsohn, D; Bertotti, M

    2001-09-01

    A method for the determination of both free and bound S(IV) in white wine samples by coulometric titration with electrogenerated iodine is described, the S(IV) speciation being performed by extracting SO2 from samples acidified wiith hydrochloric acid. Titrations of samples treated with NaOH led to the total S(IV) concentration, the results being in agreement with the ones obtained by the distillation procedure as well as by using the classical Monier-Williams method. An average recovery of 97% was obtained for samples spiked with S(IV) in the range 0.4-1.2 mM, which demonstrated the validity of the proposed procedure. The repeatability was 1.3% and the limit of detection was estimated as 0.01 mM. Results from direct titrations of wine added to the electrochemical cell are reported, which give indications of the stability of adducts towards the reaction with iodine.

  13. Demonstration of Novel Sampling Techniques for Measurement of Turbine Engine Volatile and Non-Volatile Particulate Matter (PM) Emissions

    DTIC Science & Technology

    2015-12-30

    FINAL REPORT Demonstration of Novel Sampling Techniques for Measurement of Turbine Engine Volatile and Non-Volatile Particulate Matter (PM...Novel Sampling Techniques for Measurement of Turbine Engine Volatile and Non-Volatile Particulate Matter (PM) Emissions 6. AUTHOR(S) E. Corporan, M...report contains color. 14. ABSTRACT This project consists of demonstrating the performance and viability of two devices to condition aircraft turbine

  14. Accelerated sampling by infinite swapping of path integral molecular dynamics with surface hopping

    NASA Astrophysics Data System (ADS)

    Lu, Jianfeng; Zhou, Zhennan

    2018-02-01

    To accelerate the thermal equilibrium sampling of multi-level quantum systems, the infinite swapping limit of a recently proposed multi-level ring polymer representation is investigated. In the infinite swapping limit, the ring polymer evolves according to an averaged Hamiltonian with respect to all possible surface index configurations of the ring polymer and thus connects the surface hopping approach to the mean-field path-integral molecular dynamics. A multiscale integrator for the infinite swapping limit is also proposed to enable efficient sampling based on the limiting dynamics. Numerical results demonstrate the huge improvement of sampling efficiency of the infinite swapping compared with the direct simulation of path-integral molecular dynamics with surface hopping.

  15. Accuracy assessment, using stratified plurality sampling, of portions of a LANDSAT classification of the Arctic National Wildlife Refuge Coastal Plain

    NASA Technical Reports Server (NTRS)

    Card, Don H.; Strong, Laurence L.

    1989-01-01

    An application of a classification accuracy assessment procedure is described for a vegetation and land cover map prepared by digital image processing of LANDSAT multispectral scanner data. A statistical sampling procedure called Stratified Plurality Sampling was used to assess the accuracy of portions of a map of the Arctic National Wildlife Refuge coastal plain. Results are tabulated as percent correct classification overall as well as per category with associated confidence intervals. Although values of percent correct were disappointingly low for most categories, the study was useful in highlighting sources of classification error and demonstrating shortcomings of the plurality sampling method.

  16. Cancer classification through filtering progressive transductive support vector machine based on gene expression data

    NASA Astrophysics Data System (ADS)

    Lu, Xinguo; Chen, Dan

    2017-08-01

    Traditional supervised classifiers neglect a large amount of data which not have sufficient follow-up information, only work with labeled data. Consequently, the small sample size limits the advancement of design appropriate classifier. In this paper, a transductive learning method which combined with the filtering strategy in transductive framework and progressive labeling strategy is addressed. The progressive labeling strategy does not need to consider the distribution of labeled samples to evaluate the distribution of unlabeled samples, can effective solve the problem of evaluate the proportion of positive and negative samples in work set. Our experiment result demonstrate that the proposed technique have great potential in cancer prediction based on gene expression.

  17. Sensor-triggered sampling to determine instantaneous airborne vapor exposure concentrations.

    PubMed

    Smith, Philip A; Simmons, Michael K; Toone, Phillip

    2018-06-01

    It is difficult to measure transient airborne exposure peaks by means of integrated sampling for organic chemical vapors, even with very short-duration sampling. Selection of an appropriate time to measure an exposure peak through integrated sampling is problematic, and short-duration time-weighted average (TWA) values obtained with integrated sampling are not likely to accurately determine actual peak concentrations attained when concentrations fluctuate rapidly. Laboratory analysis for integrated exposure samples is preferred from a certainty standpoint over results derived in the field from a sensor, as a sensor user typically must overcome specificity issues and a number of potential interfering factors to obtain similarly reliable data. However, sensors are currently needed to measure intra-exposure period concentration variations (i.e., exposure peaks). In this article, the digitized signal from a photoionization detector (PID) sensor triggered collection of whole-air samples when toluene or trichloroethylene vapors attained pre-determined levels in a laboratory atmosphere generation system. Analysis by gas chromatography-mass spectrometry of whole-air samples (with both 37 and 80% relative humidity) collected using the triggering mechanism with rapidly increasing vapor concentrations showed good agreement with the triggering set point values. Whole-air samples (80% relative humidity) in canisters demonstrated acceptable 17-day storage recoveries, and acceptable precision and bias were obtained. The ability to determine exceedance of a ceiling or peak exposure standard by laboratory analysis of an instantaneously collected sample, and to simultaneously provide a calibration point to verify the correct operation of a sensor was demonstrated. This latter detail may increase the confidence in reliability of sensor data obtained across an entire exposure period.

  18. Higher male educational hypergamy: evidence from Portugal.

    PubMed

    Correia, Hamilton R

    2003-04-01

    Studies of human mate choice have been based almost exclusively on stated preferences and personal advertisements, and the external validity of such studies has therefore been questioned. In the present study, real-life matings based on a large representative sample of newly wed couples in 1998 (n=66,598) were analysed according to educational assortative mating. The results demonstrate a strong educational homogamy in this national Portuguese sample. However, men tend to marry women who are slightly more educated than themselves. The results are compared with those of a modern society (US, 1940-87) and a traditional society (Kipsigis, 1952-91). Since educational attainment is strongly associated with social status and intelligence, these results are discussed in an evolutionary perspective.

  19. In situ synthesis, characterization, and catalytic performance of tungstophosphoric acid encapsulated into the framework of mesoporous silica pillared clay.

    PubMed

    Li, Baoshan; Liu, Zhenxing; Han, Chunying; Ma, Wei; Zhao, Songjie

    2012-07-01

    Mesoporous silica pillared clay (SPC) incorporated with tungstophosphoric acid (HPW) has been synthesized via in situ introducing P and W source in the acidic suspension of the clay interlayer template during the formation of the silica pillared clay. The samples were characterized by XRD, XRF, FT-IR, TG-DTA, N(2) adsorption-desorption, and SEM techniques. The results showed that the HPW formed by in situ method has been effectively introduced into the framework of mesoporous silica pillared clay and its Keggin structure remained perfectly after formation of the materials. In addition, samples with similar HPW loadings were also prepared by impregnation method using SPC as the support. HPW in the incorporated samples was better dispersed into the silica pillared clay than in the impregnated samples. The results of catalytic tests indicated that the encapsulated materials demonstrated better catalytic performance than the impregnated samples in oxidative desulfurization (ODS) of dibenzothiophene (DBT). Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Instrumental neutron activation analysis for studying size-fractionated aerosols

    NASA Astrophysics Data System (ADS)

    Salma, Imre; Zemplén-Papp, Éva

    1999-10-01

    Instrumental neutron activation analysis (INAA) was utilized for studying aerosol samples collected into a coarse and a fine size fraction on Nuclepore polycarbonate membrane filters. As a result of the panoramic INAA, 49 elements were determined in an amount of about 200-400 μg of particulate matter by two irradiations and four γ-spectrometric measurements. The analytical calculations were performed by the absolute ( k0) standardization method. The calibration procedures, application protocol and the data evaluation process are described and discussed. They make it possible now to analyse a considerable number of samples, with assuring the quality of the results. As a means of demonstrating the system's analytical capabilities, the concentration ranges, median or mean atmospheric concentrations and detection limits are presented for an extensive series of aerosol samples collected within the framework of an urban air pollution study in Budapest. For most elements, the precision of the analysis was found to be beyond the uncertainty represented by the sampling techniques and sample variability.

  1. Paradigm Diagnostics Salmonella Indicator Broth (PDX-SIB) for detection of Salmonella on selected environmental surfaces.

    PubMed

    Olstein, Alan; Griffith, Leena; Feirtag, Joellen; Pearson, Nicole

    2013-01-01

    The Paradigm Diagnostics Salmonella Indicator Broth (PDX-SIB) is intended as a single-step selective enrichment indicator broth to be used as a simple screening test for the presence of Salmonella spp. in environmental samples. This method permits the end user to avoid multistep sample processing to identify presumptively positive samples, as exemplified by standard U.S. reference methods. PDX-SIB permits the outgrowth of Salmonella while inhibiting the growth of competitive Gram-negative and -positive microflora. Growth of Salmonella-positive cultures results in a visual color change of the medium from purple to yellow when the sample is grown at 37 +/- 1 degree C. Performance of PDX-SIB has been evaluated in five different categories: inclusivity-exclusivity, methods comparison, ruggedness, lot-to-lot variability, and shelf stability. The inclusivity panel included 100 different Salmonella serovars, 98 of which were SIB-positive during the 30 to 48 h incubation period. The exclusivity panel included 33 different non-Salmonella microorganisms, 31 of which were SIB-negative during the incubation period. Methods comparison studies included four different surfaces: S. Newport on plastic, S. Anatum on sealed concrete, S. Abaetetuba on ceramic tile, and S. Typhimurium in the presence of 1 log excess of Citrobacter freundii. Results of the methods comparison studies demonstrated no statistical difference between the SIB method and the U.S. Food and Drug Administration-Bacteriological Analytical Manual reference method, as measured by the Mantel-Haenszel Chi-square test. Ruggedness studies demonstrated little variation in test results when SIB incubation temperatures were varied over a 34-40 degrees C range. Lot-to-lot consistency results suggest no detectable differences in manufactured goods using two reference Salmonella serovars and one non-Salmonella microorganism.

  2. Single chain variable fragment displaying M13 phage library functionalized magnetic microsphere-based protein equalizer for human serum protein analysis.

    PubMed

    Zhu, Guijie; Zhao, Peng; Deng, Nan; Tao, Dingyin; Sun, Liangliang; Liang, Zhen; Zhang, Lihua; Zhang, Yukui

    2012-09-18

    Single chain variable fragment (scFv) displaying the M13 phage library was covalently immobilized on magnetic microspheres and used as a protein equalizer for the treatment of human serum. First, scFv displaying M13 phage library functionalized magnetic microspheres (scFv@M13@MM) was incubated with a human serum sample. Second, captured proteins on scFv@M13@MM were eluted with 2 M NaCl, 50 mM glycine-hydrochloric acid (Gly-HCl), and 20% (v/v) acetonitrile with 0.5% (v/v) trifluoroacetic acid in sequence. Finally, the tightly bonded proteins were released by the treatment with thrombin. The eluates were first analyzed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) with silver staining. Results indicated that the difference of protein concentration was reduced obviously in NaCl and Gly-HCl fractions compared with untreated human serum sample. The eluates were also digested with trypsin, followed by online 2D-strong cation exchange (SCX)-RPLC-ESI-MS/MS analysis. Results demonstrated that the number of proteins identified from an scFv@M13@MM treated human serum sample was improved 100% compared with that from the untreated sample. In addition, the spectral count of 10 high abundance proteins (serum albumin, serotransferrin, α-2-macroglobulin, α-1-antitrypsin, apolipoprotein B-100, Ig γ-2 chain C region, haptoglobin, hemopexin, α-1-acid glycoprotein 1, and α-2-HS-glycoprotein) decreased evidently after scFv@M13@MM treatment. All these results demonstrate that scFv@M13@MM could efficiently remove high-abundance proteins, reduce the protein concentration difference of human serum, and result in more protein identification.

  3. The Efficacy of Consensus Tree Methods for Summarizing Phylogenetic Relationships from a Posterior Sample of Trees Estimated from Morphological Data.

    PubMed

    O'Reilly, Joseph E; Donoghue, Philip C J

    2018-03-01

    Consensus trees are required to summarize trees obtained through MCMC sampling of a posterior distribution, providing an overview of the distribution of estimated parameters such as topology, branch lengths, and divergence times. Numerous consensus tree construction methods are available, each presenting a different interpretation of the tree sample. The rise of morphological clock and sampled-ancestor methods of divergence time estimation, in which times and topology are coestimated, has increased the popularity of the maximum clade credibility (MCC) consensus tree method. The MCC method assumes that the sampled, fully resolved topology with the highest clade credibility is an adequate summary of the most probable clades, with parameter estimates from compatible sampled trees used to obtain the marginal distributions of parameters such as clade ages and branch lengths. Using both simulated and empirical data, we demonstrate that MCC trees, and trees constructed using the similar maximum a posteriori (MAP) method, often include poorly supported and incorrect clades when summarizing diffuse posterior samples of trees. We demonstrate that the paucity of information in morphological data sets contributes to the inability of MCC and MAP trees to accurately summarise of the posterior distribution. Conversely, majority-rule consensus (MRC) trees represent a lower proportion of incorrect nodes when summarizing the same posterior samples of trees. Thus, we advocate the use of MRC trees, in place of MCC or MAP trees, in attempts to summarize the results of Bayesian phylogenetic analyses of morphological data.

  4. The Efficacy of Consensus Tree Methods for Summarizing Phylogenetic Relationships from a Posterior Sample of Trees Estimated from Morphological Data

    PubMed Central

    O’Reilly, Joseph E; Donoghue, Philip C J

    2018-01-01

    Abstract Consensus trees are required to summarize trees obtained through MCMC sampling of a posterior distribution, providing an overview of the distribution of estimated parameters such as topology, branch lengths, and divergence times. Numerous consensus tree construction methods are available, each presenting a different interpretation of the tree sample. The rise of morphological clock and sampled-ancestor methods of divergence time estimation, in which times and topology are coestimated, has increased the popularity of the maximum clade credibility (MCC) consensus tree method. The MCC method assumes that the sampled, fully resolved topology with the highest clade credibility is an adequate summary of the most probable clades, with parameter estimates from compatible sampled trees used to obtain the marginal distributions of parameters such as clade ages and branch lengths. Using both simulated and empirical data, we demonstrate that MCC trees, and trees constructed using the similar maximum a posteriori (MAP) method, often include poorly supported and incorrect clades when summarizing diffuse posterior samples of trees. We demonstrate that the paucity of information in morphological data sets contributes to the inability of MCC and MAP trees to accurately summarise of the posterior distribution. Conversely, majority-rule consensus (MRC) trees represent a lower proportion of incorrect nodes when summarizing the same posterior samples of trees. Thus, we advocate the use of MRC trees, in place of MCC or MAP trees, in attempts to summarize the results of Bayesian phylogenetic analyses of morphological data. PMID:29106675

  5. Demonstration/Validation of Incremental Sampling at Two Diverse Military Ranges and Development of an Incremental Sampling Tool

    DTIC Science & Technology

    2010-06-01

    Sampling (MIS)? • Technique of combining many increments of soil from a number of points within exposure area • Developed by Enviro Stat (Trademarked...Demonstrating a reliable soil sampling strategy to accurately characterize contaminant concentrations in spatially extreme and heterogeneous...into a set of decision (exposure) units • One or several discrete or small- scale composite soil samples collected to represent each decision unit

  6. In-situ pre-concentration through repeated sampling and pyrolysis for ultrasensitive determination of thallium in drinking water by electrothermal atomic absorption spectrometry.

    PubMed

    Liu, Liwei; Zheng, Huaili; Xu, Bincheng; Xiao, Lang; Chigan, Yong; Zhangluo, Yilan

    2018-03-01

    In this paper, a procedure for in-situ pre-concentration in graphite furnace by repeated sampling and pyrolysis is proposed for the determination of ultra-trace thallium in drinking water by graphite furnace atomic absorption spectrometry (GF-AAS). Without any other laborious enrichment processes that routinely result in analyte loss and contamination, thallium was directly concentrated in the graphite furnace automatically and subsequently subject to analysis. The effects of several key factors, such as the temperature for pyrolysis and atomization, the chemical modifier, and the repeated sampling times were investigated. Under the optimized conditions, a limit of detection of 0.01µgL -1 was obtained, which fulfilled thallium determination in drinking water by GB 5749-2006 regulated by China. Successful analysis of thallium in certified water samples and drinking water samples was demonstrated, with analytical results in good agreement with the certified values and those by inductively coupled plasma mass spectrometry (ICP-MS), respectively. Routine spike-recovery tests with randomly selected drinking water samples showed satisfactory results of 80-96%. The proposed method is simple and sensitive for screening of ultra-trace thallium in drinking water samples. Copyright © 2017. Published by Elsevier B.V.

  7. Explosive detection using high-volume vapor sampling and analysis by trained canines and ultra-trace detection equipment

    NASA Astrophysics Data System (ADS)

    Fisher, Mark; Sikes, John; Prather, Mark

    2004-09-01

    The dog's nose is an effective, highly-mobile sampling system, while the canine olfactory organs are an extremely sensitive detector. Having been trained to detect a wide variety of substances with exceptional results, canines are widely regarded as the 'gold standard' in chemical vapor detection. Historically, attempts to mimic the ability of dogs to detect vapors of explosives using electronic 'dogs noses' has proven difficult. However, recent advances in technology have resulted in development of detection (i.e., sampling and sensor) systems with performance that is rapidly approaching that of trained canines. The Nomadics Fido was the first sensor to demonstrate under field conditions the detection of landmines with performance approaching that of canines. More recently, comparative testing of Fido against canines has revealed that electronic vapor detection, when coupled with effective sampling methods, can produce results comparable to that of highly-trained canines. The results of these comparative tests will be presented, as will recent test results in which explosives hidden in cargo were detected using Fido with a high-volume sampling technique. Finally, the use of canines along with electronic sensors will be discussed as a means of improving the performance and expanding the capabilities of both methods.

  8. Laboratory and Airborne BRDF Analysis of Vegetation Leaves and Soil Samples

    NASA Technical Reports Server (NTRS)

    Georgiev, Georgi T.; Gatebe, Charles K.; Butler, James J.; King, Michael D.

    2008-01-01

    Laboratory-based Bidirectional Reflectance Distribution Function (BRDF) analysis of vegetation leaves, soil, and leaf litter samples is presented. The leaf litter and soil samples, numbered 1 and 2, were obtained from a site located in the savanna biome of South Africa (Skukuza: 25.0degS, 31.5degE). A third soil sample, number 3, was obtained from Etosha Pan, Namibia (19.20degS, 15.93degE, alt. 1100 m). In addition, BRDF of local fresh and dry leaves from tulip tree (Liriodendron tulipifera) and acacia tree (Acacia greggii) were studied. It is shown how the BRDF depends on the incident and scatter angles, sample size (i.e. crushed versus whole leaf,) soil samples fraction size, sample status (i.e. fresh versus dry leaves), vegetation species (poplar versus acacia), and vegetation s biochemical composition. As a demonstration of the application of the results of this study, airborne BRDF measurements acquired with NASA's Cloud Absorption Radiometer (CAR) over the same general site where the soil and leaf litter samples were obtained are compared to the laboratory results. Good agreement between laboratory and airborne measured BRDF is reported.

  9. Personality Correlates of Machiavellianism: VI. Machiavellianism and the Psychopath.

    ERIC Educational Resources Information Center

    Skinner, Nicholas F.

    1988-01-01

    Previous studies have not demonstrated hypothesized link between Machiavellianism (interpersonally manipulative behavior) and psychopathy. Results from two studies using college student samples revealed that High Machs obtained significantly higher Psychopathy scores than did Low Machs, and Mach V totals for Primary Psychopaths were significantly…

  10. Chirality, Metallicity, and Transition Dependent Asymmetries in Resonance Raman Excitation Profiles of Chirality-Enriched Carbon Nanotubes

    NASA Astrophysics Data System (ADS)

    Doorn, Stephen; Duque, Juan; Telg, Hagen; Haroz, Erik; Tu, Xiaomin; Zheng, Ming

    2014-03-01

    Access to carbon nanotube samples enriched in single chiralities allows the observation of new photophysical behaviors obscured or difficult to demonstrate in mixed-chirality ensembles. Recent examples include the observation of strongly asymmetric G-band excitation profiles resulting from non-Condon effects1 and the unambiguous demonstration of Raman interference effects.2 We present here our most recent results demonstrating the generality of the non-Condon behavior to include metallic species (specifically several armchair chiralities). Additionally, the Eii dependence in non-Condon behavior with excitations from E11 thru E44 for both RBM and G modes will be discussed. 1. J.G. Duque, et. al., ACS Nano, 5, 5233 (2011). 2. J.G. Duque, et. al., Phys. Rev. Lett. 108, 117404 (2012).

  11. Modulators of Bufo arenarum ovulation.

    PubMed

    Ramos, Inés; Cisint, Susana B; Crespo, Claudia A; Medina, Marcela F; Fernández, Silvia N

    2008-02-01

    In this study we investigated ovulation in vitro using ovary samples from Bufo arenarum with respect to their response to stimulation with homologous pituitary homogenate (HPH) or with progesterone and prostaglandins (PGF2alpha and PGE1) as intermediates of pituitary action. Ovary samples were obtained from animals captured during the breeding period. Our results demonstrate that the ovulatory response to all different inducers was dose dependent, the highest percentage of ovulated oocytes being obtained with HPH treatment. An important increase in the ovulatory response was obtained by the association of PGF2alpha with either HPH or progesterone at suboptimal doses, indicating that this prostaglandin induced a synergistic potentiating effect. Incubation with cyclooxygenase inhibitors (indomethacin or diclofenac sodium) produced a significant decrease in the ovulation induced by HPH, demonstrating that prostaglandins are involved in the action of the pituitary gland in this process. According to our results, PGE1 not only had no participation in the ovulatory process, but also produced an inhibitory effect on ovulation induced by HPH treatment.

  12. The development and validation of the Physical Appearance Comparison Scale-Revised (PACS-R).

    PubMed

    Schaefer, Lauren M; Thompson, J Kevin

    2014-04-01

    The Physical Appearance Comparison Scale (PACS; Thompson, Heinberg, & Tantleff, 1991) was revised to assess appearance comparisons relevant to women and men in a wide variety of contexts. The revised scale (Physical Appearance Comparison Scale-Revised, PACS-R) was administered to 1176 college females. In Study 1, exploratory factor analysis and parallel analysis using one half of the sample suggested a single factor structure for the PACS-R. Study 2 utilized the remaining half of the sample to conduct confirmatory factor analysis, item analysis, and to examine the convergent validity of the scale. These analyses resulted in an 11-item measure that demonstrated excellent internal consistency and convergent validity with measures of body satisfaction, eating pathology, sociocultural influences on appearance, and self-esteem. Regression analyses demonstrated the utility of the PACS-R in predicting body satisfaction and eating pathology. Overall, results indicate that the PACS-R is a reliable and valid tool for assessing appearance comparison tendencies in women. Copyright © 2014. Published by Elsevier Ltd.

  13. Senescence-associated SIN3B promotes inflammation and pancreatic cancer progression

    PubMed Central

    Rielland, Maïté; Cantor, David J.; Graveline, Richard; Hajdu, Cristina; Mara, Lisa; de Diego Diaz, Beatriz; Miller, George; David, Gregory

    2014-01-01

    Pancreatic ductal adenocarcinoma (PDAC) is strikingly resistant to conventional therapeutic approaches. We previously demonstrated that the histone deacetylase–associated protein SIN3B is essential for oncogene-induced senescence in cultured cells. Here, using a mouse model of pancreatic cancer, we have demonstrated that SIN3B is required for activated KRAS-induced senescence in vivo. Surprisingly, impaired senescence as the result of genetic inactivation of Sin3B was associated with delayed PDAC progression and correlated with an impaired inflammatory response. In murine and human pancreatic cells and tissues, levels of SIN3B correlated with KRAS-induced production of IL-1α. Furthermore, evaluation of human pancreatic tissue and cancer cells revealed that Sin3B was decreased in control and PDAC samples, compared with samples from patients with pancreatic inflammation. These results indicate that senescence-associated inflammation positively correlates with PDAC progression and suggest that SIN3B has potential as a therapeutic target for inhibiting inflammation-driven tumorigenesis. PMID:24691445

  14. Modeling abundance using multinomial N-mixture models

    USGS Publications Warehouse

    Royle, Andy

    2016-01-01

    Multinomial N-mixture models are a generalization of the binomial N-mixture models described in Chapter 6 to allow for more complex and informative sampling protocols beyond simple counts. Many commonly used protocols such as multiple observer sampling, removal sampling, and capture-recapture produce a multivariate count frequency that has a multinomial distribution and for which multinomial N-mixture models can be developed. Such protocols typically result in more precise estimates than binomial mixture models because they provide direct information about parameters of the observation process. We demonstrate the analysis of these models in BUGS using several distinct formulations that afford great flexibility in the types of models that can be developed, and we demonstrate likelihood analysis using the unmarked package. Spatially stratified capture-recapture models are one class of models that fall into the multinomial N-mixture framework, and we discuss analysis of stratified versions of classical models such as model Mb, Mh and other classes of models that are only possible to describe within the multinomial N-mixture framework.

  15. Computationally-efficient optical coherence elastography to assess degenerative osteoarthritis based on ultrasound-induced fringe washout (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Tong, Minh Q.; Hasan, M. Monirul; Gregory, Patrick D.; Shah, Jasmine; Park, B. Hyle; Hirota, Koji; Liu, Junze; Choi, Andy; Low, Karen; Nam, Jin

    2017-02-01

    We demonstrate a computationally-efficient optical coherence elastography (OCE) method based on fringe washout. By introducing ultrasound in alternating depth profile, we can obtain information on the mechanical properties of a sample within acquisition of a single image. This can be achieved by simply comparing the intensity in adjacent depth profiles in order to quantify the degree of fringe washout. Phantom agar samples with various densities were measured and quantified by our OCE technique, the correlation to Young's modulus measurement by atomic force micrscopy (AFM) were observed. Knee cartilage samples of monoiodo acetate-induced arthiritis (MIA) rat models were utilized to replicate cartilage damages where our proposed OCE technique along with intensity and birefringence analyses and AFM measurements were applied. The results indicate that our OCE technique shows a correlation to the techniques as polarization-sensitive OCT, AFM Young's modulus measurements and histology were promising. Our OCE is applicable to any of existing OCT systems and demonstrated to be computationally-efficient.

  16. Validation of the Implementation Leadership Scale (ILS) with Supervisors' Self-Ratings.

    PubMed

    Torres, Elisa M; Ehrhart, Mark G; Beidas, Rinad S; Farahnak, Lauren R; Finn, Natalie K; Aarons, Gregory A

    2018-01-01

    Although often discussed, there is a lack of empirical research on the role of leadership in the management and delivery of health services. The implementation leadership scale (ILS) assesses the degree to which leaders are knowledgeable, proactive, perseverant, and supportive during evidence-based practice (EBP) implementation. The purpose of this study was to examine the psychometric properties of the ILS for leaders' self-ratings using a sample of mental health clinic supervisors (N = 119). Supervisors (i.e., leaders) completed surveys including self-ratings of their implementation leadership. Confirmatory factor analysis, reliability, and validity of the ILS were evaluated. The ILS factor structure was supported in the sample of supervisors. Results demonstrated internal consistency reliability and validity. Cronbach alpha's ranged from 0.92 to 0.96 for the ILS subscales and 0.95 for the ILS overall scale. The factor structure replication and reliability of the ILS in a sample of supervisors demonstrates its applicability with employees across organizational levels.

  17. Structure determination of an integral membrane protein at room temperature from crystals in situ

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Axford, Danny; Foadi, James; Imperial College London, London SW7 2AZ

    2015-05-14

    The X-ray structure determination of an integral membrane protein using synchrotron diffraction data measured in situ at room temperature is demonstrated. The structure determination of an integral membrane protein using synchrotron X-ray diffraction data collected at room temperature directly in vapour-diffusion crystallization plates (in situ) is demonstrated. Exposing the crystals in situ eliminates manual sample handling and, since it is performed at room temperature, removes the complication of cryoprotection and potential structural anomalies induced by sample cryocooling. Essential to the method is the ability to limit radiation damage by recording a small amount of data per sample from many samplesmore » and subsequently assembling the resulting data sets using specialized software. The validity of this procedure is established by the structure determination of Haemophilus influenza TehA at 2.3 Å resolution. The method presented offers an effective protocol for the fast and efficient determination of membrane-protein structures at room temperature using third-generation synchrotron beamlines.« less

  18. Using the MMPI-2-RF to discriminate psychometrically identified schizotypic college students from a matched comparison sample.

    PubMed

    Hunter, Helen K; Bolinskey, P Kevin; Novi, Jonathan H; Hudak, Daniel V; James, Alison V; Myers, Kevin R; Schuder, Kelly M

    2014-01-01

    This study investigates the extent to which the Minnesota Multiphasic Personality Inventory-2 Restructured Form (MMPI-2-RF) profiles of 52 individuals making up a psychometrically identified schizotypes (SZT) sample could be successfully discriminated from the protocols of 52 individuals in a matched comparison (MC) sample. Replication analyses were performed with an additional 53 pairs of SZT and MC participants. Results showed significant differences in mean T-score values between these 2 groups across a variety of MMPI-2-RF scales. Results from discriminant function analyses indicate that schizotypy can be predicted effectively using 4 MMPI-2-RF scales and that this method of classification held up on replication. Additional results demonstrated that these MMPI-2-RF scales nominally outperformed MMPI-2 scales suggested by previous research as being indicative of schizophrenia liability. Directions for future research with the MMPI-2-RF are suggested.

  19. Analysis of image formation in optical coherence elastography using a multiphysics approach

    PubMed Central

    Chin, Lixin; Curatolo, Andrea; Kennedy, Brendan F.; Doyle, Barry J.; Munro, Peter R. T.; McLaughlin, Robert A.; Sampson, David D.

    2014-01-01

    Image formation in optical coherence elastography (OCE) results from a combination of two processes: the mechanical deformation imparted to the sample and the detection of the resulting displacement using optical coherence tomography (OCT). We present a multiphysics model of these processes, validated by simulating strain elastograms acquired using phase-sensitive compression OCE, and demonstrating close correspondence with experimental results. Using the model, we present evidence that the approximation commonly used to infer sample displacement in phase-sensitive OCE is invalidated for smaller deformations than has been previously considered, significantly affecting the measurement precision, as quantified by the displacement sensitivity and the elastogram signal-to-noise ratio. We show how the precision of OCE is affected not only by OCT shot-noise, as is usually considered, but additionally by phase decorrelation due to the sample deformation. This multiphysics model provides a general framework that could be used to compare and contrast different OCE techniques. PMID:25401007

  20. Field Detection of Drugs of Abuse in Oral Fluid Using the Alere™ DDS®2 Mobile Test System with Confirmation by Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS).

    PubMed

    Krotulski, Alex J; Mohr, Amanda L A; Friscia, Melissa; Logan, Barry K

    2018-04-01

    The collection and analysis of drugs in oral fluid (OF) at the roadside has become more feasible with the introduction of portable testing devices such as the Alere™ DDS®2 Mobile Test System (DDS®2). The objective of this study was to compare the on-site results for the DDS®2 to laboratory-based confirmatory assays with respect to detection of drugs of abuse in human subjects. As part of a larger Institutional Review Board approved study, two OF samples were collected from each participant at a music festival in Miami, FL, USA. One OF sample was field screened using the DDS®2, and a confirmatory OF sample was collected using the Quantisal™ OF collection device and submitted to the laboratory for testing. In total, 124 subjects participated in this study providing two contemporaneous OF samples. DDS®2 field screening yielded positive results for delta-9-tetrahydrocannabinol (THC) (n = 27), cocaine (n = 12), amphetamine (n = 3), methamphetamine (n = 3) and benzodiazepine (n = 1). No opiate-positive OF samples were detected. For cocaine, amphetamine, methamphetamine and benzodiazepines, the DDS®2 displayed sensitivity, specificity and accuracy of 100%. For THC, the DDS®2 displayed sensitivity of 90%, specificity of 100% and accuracy of 97.5%, when the threshold for confirmation matched that of the manufacturers advertised cut-off. When this confirmatory threshold was lowered to the analytical limit of detection (i.e., 1 ng/mL), apparent device performance for THC was poorer due to additional samples testing positive by confirmatory assay that had tested negative on the DDS®2, demonstrating a need for correlation between manufacturer cut-off and analytical reporting limit. These results from drug-using subjects demonstrate the value of field-based OF testing, and illustrate the significance of selecting an appropriate confirmation cut-off concentration with respect to performance evaluation and detection of drug use.

  1. Performance monitoring in hip fracture surgery--how big a database do we really need?

    PubMed

    Edwards, G A D; Metcalfe, A J; Johansen, A; O'Doherty, D

    2010-04-01

    Systems for collecting information about patient care are increasingly common in orthopaedic practice. Databases can allow various comparisons to be made over time. Significant decisions regarding service delivery and clinical practice may be made based on their results. We set out to determine the number of cases needed for comparison of 30-day mortality, inpatient wound infection rates and mean hospital length of stay, with a power of 80% for the demonstration of an effect at a significance level of p<0.05. We analysed 2 years of prospectively collected data on 1050 hip fracture patients admitted to a city teaching hospital. Detection of a 10% difference in 30-day mortality would require 14,065 patients in each arm of any comparison, demonstration of a 50% difference would require 643 patients in each arm; for wound infections, demonstration of a 10% difference in incidence would require 23,921 patients in each arm and 1127 patients for demonstration of a 50% difference; for length of stay, a difference of 10% would require 1479 patients and 6660 patients for a 50% difference. This study demonstrates the importance of considering the population sizes before comparisons are made on the basis of basic hip fracture outcome data. Our data also help illustrate the impact of sample size considerations when interpreting the results of performance monitoring. Many researchers will be used to the fact that rare outcomes such as inpatient mortality or wound infection require large sample sizes before differences can be reliably demonstrated between populations. This study gives actual figures that researchers could use when planning studies. Statistically meaningful analyses will only be possible with major multi-centre collaborations, as will be possible if hospital Trusts participate in the National Hip Fracture Database. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  2. Cost-effective and Rapid Blood Analysis on a Cell-phone

    PubMed Central

    Zhu, Hongying; Sencan, Ikbal; Wong, Justin; Dimitrov, Stoyan; Tseng, Derek; Nagashima, Keita; Ozcan, Aydogan

    2013-01-01

    We demonstrate a compact and cost-effective imaging cytometry platform installed on a cell-phone for the measurement of the density of red and white blood cells as well as hemoglobin concentration in human blood samples. Fluorescent and bright-field images of blood samples are captured using separate optical attachments to the cell-phone and are rapidly processed through a custom-developed smart application running on the phone for counting of blood cells and determining hemoglobin density. We evaluated the performance of this cell-phone based blood analysis platform using anonymous human blood samples and achieved comparable results to a standard bench-top hematology analyser. Test results can either be stored on the cell-phone memory or be transmitted to a central server, providing remote diagnosis opportunities even in field settings. PMID:23392286

  3. Cost-effective and rapid blood analysis on a cell-phone.

    PubMed

    Zhu, Hongying; Sencan, Ikbal; Wong, Justin; Dimitrov, Stoyan; Tseng, Derek; Nagashima, Keita; Ozcan, Aydogan

    2013-04-07

    We demonstrate a compact and cost-effective imaging cytometry platform installed on a cell-phone for the measurement of the density of red and white blood cells as well as hemoglobin concentration in human blood samples. Fluorescent and bright-field images of blood samples are captured using separate optical attachments to the cell-phone and are rapidly processed through a custom-developed smart application running on the phone for counting of blood cells and determining hemoglobin density. We evaluated the performance of this cell-phone based blood analysis platform using anonymous human blood samples and achieved comparable results to a standard bench-top hematology analyser. Test results can either be stored on the cell-phone memory or be transmitted to a central server, providing remote diagnosis opportunities even in field settings.

  4. Problematic Social Media Use: Results from a Large-Scale Nationally Representative Adolescent Sample

    PubMed Central

    Bányai, Fanni; Zsila, Ágnes; Király, Orsolya; Maraz, Aniko; Elekes, Zsuzsanna; Griffiths, Mark D.; Andreassen, Cecilie Schou

    2017-01-01

    Despite social media use being one of the most popular activities among adolescents, prevalence estimates among teenage samples of social media (problematic) use are lacking in the field. The present study surveyed a nationally representative Hungarian sample comprising 5,961 adolescents as part of the European School Survey Project on Alcohol and Other Drugs (ESPAD). Using the Bergen Social Media Addiction Scale (BSMAS) and based on latent profile analysis, 4.5% of the adolescents belonged to the at-risk group, and reported low self-esteem, high level of depression symptoms, and elevated social media use. Results also demonstrated that BSMAS has appropriate psychometric properties. It is concluded that adolescents at-risk of problematic social media use should be targeted by school-based prevention and intervention programs. PMID:28068404

  5. Problematic Social Media Use: Results from a Large-Scale Nationally Representative Adolescent Sample.

    PubMed

    Bányai, Fanni; Zsila, Ágnes; Király, Orsolya; Maraz, Aniko; Elekes, Zsuzsanna; Griffiths, Mark D; Andreassen, Cecilie Schou; Demetrovics, Zsolt

    2017-01-01

    Despite social media use being one of the most popular activities among adolescents, prevalence estimates among teenage samples of social media (problematic) use are lacking in the field. The present study surveyed a nationally representative Hungarian sample comprising 5,961 adolescents as part of the European School Survey Project on Alcohol and Other Drugs (ESPAD). Using the Bergen Social Media Addiction Scale (BSMAS) and based on latent profile analysis, 4.5% of the adolescents belonged to the at-risk group, and reported low self-esteem, high level of depression symptoms, and elevated social media use. Results also demonstrated that BSMAS has appropriate psychometric properties. It is concluded that adolescents at-risk of problematic social media use should be targeted by school-based prevention and intervention programs.

  6. A new method for detecting, quantifying and monitoring diffuse contamination

    NASA Astrophysics Data System (ADS)

    Fabian, Karl; Reimann, Clemens; de Caritat, Patrice

    2017-04-01

    A new method is presented for detecting and quantifying diffuse contamination at the regional to continental scale. It is based on the analysis of cumulative distribution functions (CDFs) in cumulative probability (CP) plots for spatially representative datasets, preferably containing >1000 samples. Simulations demonstrate how different types of contamination influence elemental CDFs of different sample media. Contrary to common belief, diffuse contamination does not result in exceedingly high element concentrations in regional- to continental-scale datasets. Instead it produces a distinctive shift of concentrations in the background distribution of the studied element resulting in a steeper data distribution in the CP plot. Via either (1) comparing the distribution of an element in top soil samples to the distribution of the same element in bottom soil samples from the same area, taking soil forming processes into consideration, or (2) comparing the distribution of the contaminating element (e.g., Pb) to that of an element with a geochemically comparable behaviour but no contamination source (e.g., Rb or Ba in case of Pb), the relative impact of diffuse contamination on the element concentration can be estimated either graphically in the CP plot via a best fit estimate or quantitatively via a Kolmogorov-Smirnov or Cramer vonMiese test. This is demonstrated using continental-scale geochemical soil datasets from Europe, Australia, and the USA, and a regional scale dataset from Norway. Several different datasets from Europe deliver comparable results at regional to continental scales. The method is also suitable for monitoring diffuse contamination based on the statistical distribution of repeat datasets at the continental scale in a cost-effective manner.

  7. Assessment of changes in crystallization properties of pressurized milk fat.

    PubMed

    Staniewski, Bogusław; Smoczyński, Michał; Staniewska, Katarzyna; Baranowska, Maria; Kiełczewska, Katarzyna; Zulewska, Justyna

    2015-04-01

    The aim of the study was to demonstrate the use of fractal image analysis as a possible tool to monitor the effect of pressurization on the crystallization pattern of anhydrous milk fat. This approach can be useful when developing new products based on milk fat. The samples were subjected to different hydrostatic pressure (100, 200, 300, and 400 MPa) and temperature (10 and 40 °C) treatments. The crystallization microphotographs were taken with a scanning electron microscope. The image analysis of scanning electron microscope photographs was done to determine a fractal dimension. Milk-fat pressurization under the applied parameters resulted in slight, but statistically significant, changes in the course of crystallization curves, related to the triacylglycerol fraction crystallizing in the lowest temperature (I exothermic effect). These changes were dependent on the value of pressure but not dependent on the temperatures applied during the process of pressurization (at either 10 or 40 °C). In turn, significant differences were observed in crystallization images of milk-fat samples subjected to this process compared with the control sample. The results of additional fractal analysis additionally demonstrated the highest degree of irregularity of the surface of the crystalline form for the nonpressurized sample and the samples pressurized at 200 and 300 MPa at 10 °C. The lowest value of fractal dimension-indicative of the least irregularity-was achieved for the fat samples pressurized at 400 MPa, 10 °C and at 100 MPa, 40 °C. The possibilities of wider application of the fractal analysis for the evaluation of effects of parameters of various technological processes on crystallization properties of milk fat require further extensive investigations. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  8. NanoDrop Microvolume Quantitation of Nucleic Acids

    PubMed Central

    Desjardins, Philippe; Conklin, Deborah

    2010-01-01

    Biomolecular assays are continually being developed that use progressively smaller amounts of material, often precluding the use of conventional cuvette-based instruments for nucleic acid quantitation for those that can perform microvolume quantitation. The NanoDrop microvolume sample retention system (Thermo Scientific NanoDrop Products) functions by combining fiber optic technology and natural surface tension properties to capture and retain minute amounts of sample independent of traditional containment apparatus such as cuvettes or capillaries. Furthermore, the system employs shorter path lengths, which result in a broad range of nucleic acid concentration measurements, essentially eliminating the need to perform dilutions. Reducing the volume of sample required for spectroscopic analysis also facilitates the inclusion of additional quality control steps throughout many molecular workflows, increasing efficiency and ultimately leading to greater confidence in downstream results. The need for high-sensitivity fluorescent analysis of limited mass has also emerged with recent experimental advances. Using the same microvolume sample retention technology, fluorescent measurements may be performed with 2 μL of material, allowing fluorescent assays volume requirements to be significantly reduced. Such microreactions of 10 μL or less are now possible using a dedicated microvolume fluorospectrometer. Two microvolume nucleic acid quantitation protocols will be demonstrated that use integrated sample retention systems as practical alternatives to traditional cuvette-based protocols. First, a direct A260 absorbance method using a microvolume spectrophotometer is described. This is followed by a demonstration of a fluorescence-based method that enables reduced-volume fluorescence reactions with a microvolume fluorospectrometer. These novel techniques enable the assessment of nucleic acid concentrations ranging from 1 pg/ μL to 15,000 ng/ μL with minimal consumption of sample. PMID:21189466

  9. Cross-shore and Vertical Distributions of Invertebrate Larvae Using Autonomous Sampling Coupled with Genetic Analysis

    NASA Astrophysics Data System (ADS)

    Govindarajan, A.; Pineda, J.; Purcell, M.; Tradd, K.; Packard, G.; Girard, A.; Dennett, M.; Breier, J. A., Jr.

    2016-02-01

    We present a new method to estimate the distribution of invertebrate larvae relative to environmental variables such as temperature, salinity, and circulation. A large volume in situ filtering system developed for discrete biogeochemical sampling in the deep-sea (the Suspended Particulate Rosette "SUPR" multisampler) was mounted to the autonomous underwater vehicle REMUS 600 for coastal larval and environmental sampling. We describe the results of SUPR-REMUS deployments conducted in Buzzards Bay, Massachusetts (2014) and west of Martha's Vineyard, Massachusetts (2015). We collected discrete samples cross-shore and from surface, middle, and bottom layers of the water column. Samples were preserved for DNA analysis. Our Buzzards Bay deployment targeted barnacle larvae, which are abundant in late winter and early spring. For these samples, we used morphological analysis and DNA barcodes generated by Sanger sequencing to obtain stage and species-specific cross-shore and vertical distributions. We targeted bivalve larvae in our 2015 deployments, and genetic analysis of larvae from these samples is underway. For these samples, we are comparing species barcode data derived from traditional Sanger sequencing of individuals to those obtained from next generation sequencing (NGS) of bulk plankton samples. Our results demonstrate the utility of autonomous sampling combined with DNA barcoding for studying larval distributions and transport dynamics.

  10. Network Model-Assisted Inference from Respondent-Driven Sampling Data

    PubMed Central

    Gile, Krista J.; Handcock, Mark S.

    2015-01-01

    Summary Respondent-Driven Sampling is a widely-used method for sampling hard-to-reach human populations by link-tracing over their social networks. Inference from such data requires specialized techniques because the sampling process is both partially beyond the control of the researcher, and partially implicitly defined. Therefore, it is not generally possible to directly compute the sampling weights for traditional design-based inference, and likelihood inference requires modeling the complex sampling process. As an alternative, we introduce a model-assisted approach, resulting in a design-based estimator leveraging a working network model. We derive a new class of estimators for population means and a corresponding bootstrap standard error estimator. We demonstrate improved performance compared to existing estimators, including adjustment for an initial convenience sample. We also apply the method and an extension to the estimation of HIV prevalence in a high-risk population. PMID:26640328

  11. Network Model-Assisted Inference from Respondent-Driven Sampling Data.

    PubMed

    Gile, Krista J; Handcock, Mark S

    2015-06-01

    Respondent-Driven Sampling is a widely-used method for sampling hard-to-reach human populations by link-tracing over their social networks. Inference from such data requires specialized techniques because the sampling process is both partially beyond the control of the researcher, and partially implicitly defined. Therefore, it is not generally possible to directly compute the sampling weights for traditional design-based inference, and likelihood inference requires modeling the complex sampling process. As an alternative, we introduce a model-assisted approach, resulting in a design-based estimator leveraging a working network model. We derive a new class of estimators for population means and a corresponding bootstrap standard error estimator. We demonstrate improved performance compared to existing estimators, including adjustment for an initial convenience sample. We also apply the method and an extension to the estimation of HIV prevalence in a high-risk population.

  12. Combining gas-phase electrophoretic mobility molecular analysis (GEMMA), light scattering, field flow fractionation and cryo electron microscopy in a multidimensional approach to characterize liposomal carrier vesicles

    PubMed Central

    Gondikas, Andreas; von der Kammer, Frank; Hofmann, Thilo; Marchetti-Deschmann, Martina; Allmaier, Günter; Marko-Varga, György; Andersson, Roland

    2017-01-01

    For drug delivery, characterization of liposomes regarding size, particle number concentrations, occurrence of low-sized liposome artefacts and drug encapsulation are of importance to understand their pharmacodynamic properties. In our study, we aimed to demonstrate the applicability of nano Electrospray Gas-Phase Electrophoretic Mobility Molecular Analyser (nES GEMMA) as a suitable technique for analyzing these parameters. We measured number-based particle concentrations, identified differences in size between nominally identical liposomal samples, and detected the presence of low-diameter material which yielded bimodal particle size distributions. Subsequently, we compared these findings to dynamic light scattering (DLS) data and results from light scattering experiments coupled to Asymmetric Flow-Field Flow Fractionation (AF4), the latter improving the detectability of smaller particles in polydisperse samples due to a size separation step prior detection. However, the bimodal size distribution could not be detected due to method inherent limitations. In contrast, cryo transmission electron microscopy corroborated nES GEMMA results. Hence, gas-phase electrophoresis proved to be a versatile tool for liposome characterization as it could analyze both vesicle size and size distribution. Finally, a correlation of nES GEMMA results with cell viability experiments was carried out to demonstrate the importance of liposome batch-to-batch control as low-sized sample components possibly impact cell viability. PMID:27639623

  13. Sampling from complex networks using distributed learning automata

    NASA Astrophysics Data System (ADS)

    Rezvanian, Alireza; Rahmati, Mohammad; Meybodi, Mohammad Reza

    2014-02-01

    A complex network provides a framework for modeling many real-world phenomena in the form of a network. In general, a complex network is considered as a graph of real world phenomena such as biological networks, ecological networks, technological networks, information networks and particularly social networks. Recently, major studies are reported for the characterization of social networks due to a growing trend in analysis of online social networks as dynamic complex large-scale graphs. Due to the large scale and limited access of real networks, the network model is characterized using an appropriate part of a network by sampling approaches. In this paper, a new sampling algorithm based on distributed learning automata has been proposed for sampling from complex networks. In the proposed algorithm, a set of distributed learning automata cooperate with each other in order to take appropriate samples from the given network. To investigate the performance of the proposed algorithm, several simulation experiments are conducted on well-known complex networks. Experimental results are compared with several sampling methods in terms of different measures. The experimental results demonstrate the superiority of the proposed algorithm over the others.

  14. A new x-ray interface and surface scattering environmental cell design for in situ studies of radioactive and atmosphere-sensitive samples.

    PubMed

    Schmidt, M; Eng, P J; Stubbs, J E; Fenter, P; Soderholm, L

    2011-07-01

    We present a novel design of a purpose-built, portable sample cell for in situ x-ray scattering experiments of radioactive or atmosphere sensitive samples. The cell has a modular design that includes two independent layers of containment that are used simultaneously to isolate the sensitive samples. Both layers of containment can be flushed with an inert gas, thus serving a double purpose as containment of radiological material (either as a solid sample or as a liquid phase) and in separating reactive samples from the ambient atmosphere. A remote controlled solution flow system is integrated into the containment system that allows sorption experiments to be performed on the diffractometer. The cell's design is discussed in detail and we demonstrate the cell's performance by presenting first results of crystal truncation rod measurements. The results were obtained from muscovite mica single crystals reacted with 1 mM solutions of Th(IV) with 0.1 M NaCl background electrolyte. Data were obtained in specular as well as off-specular geometry.

  15. White HDPE bottles as source of serious contamination of water samples with Ba and Zn.

    PubMed

    Reimann, Clemens; Grimstvedt, Andreas; Frengstad, Bjørn; Finne, Tor Erik

    2007-03-15

    During a recent study of surface water quality factory new white high-density polyethylene (HDPE) bottles were used for collecting the water samples. According to the established field protocol of the Geological Survey of Norway the bottles were twice carefully rinsed with water in the field prior to sampling. Several blank samples using milli-Q (ELGA) water (>18.2 MOmega) were also prepared. On checking the analytical results the blanks returned values of Ag, Ba, Sr, V, Zn and Zr. For Ba and Zn the values (c. 300 microg/l and 95 microg/l) were about 10 times above the concentrations that can be expected in natural waters. A laboratory test of the bottles demonstrated that the bottles contaminate the samples with significant amounts of Ba and Zn and some Sr. Simple acid washing of the bottles prior to use did not solve the contamination problem for Ba and Zn. The results suggest that there may exist "clean" and "dirty" HDPE bottles depending on manufacturer/production process. When collecting water samples it is mandatory to check bottles regularly as a possible source of contamination.

  16. The development of a Martian atmospheric Sample collection canister

    NASA Astrophysics Data System (ADS)

    Kulczycki, E.; Galey, C.; Kennedy, B.; Budney, C.; Bame, D.; Van Schilfgaarde, R.; Aisen, N.; Townsend, J.; Younse, P.; Piacentine, J.

    The collection of an atmospheric sample from Mars would provide significant insight to the understanding of the elemental composition and sub-surface out-gassing rates of noble gases. A team of engineers at the Jet Propulsion Laboratory (JPL), California Institute of Technology have developed an atmospheric sample collection canister for Martian application. The engineering strategy has two basic elements: first, to collect two separately sealed 50 cubic centimeter unpressurized atmospheric samples with minimal sensing and actuation in a self contained pressure vessel; and second, to package this atmospheric sample canister in such a way that it can be easily integrated into the orbiting sample capsule for collection and return to Earth. Sample collection and integrity are demonstrated by emulating the atmospheric collection portion of the Mars Sample Return mission on a compressed timeline. The test results achieved by varying the pressure inside of a thermal vacuum chamber while opening and closing the valve on the sample canister at Mars ambient pressure. A commercial off-the-shelf medical grade micro-valve is utilized in the first iteration of this design to enable rapid testing of the system. The valve has been independently leak tested at JPL to quantify and separate the leak rates associated with the canister. The results are factored in to an overall system design that quantifies mass, power, and sensing requirements for a Martian atmospheric Sample Collection (MASC) canister as outlined in the Mars Sample Return mission profile. Qualitative results include the selection of materials to minimize sample contamination, preliminary science requirements, priorities in sample composition, flight valve selection criteria, a storyboard from sample collection to loading in the orbiting sample capsule, and contributions to maintaining “ Earth” clean exterior surfaces on the orbiting sample capsule.

  17. A Blueprint for Demonstrating Quantum Supremacy with Superconducting Qubits

    NASA Technical Reports Server (NTRS)

    Kechedzhi, Kostyantyn

    2018-01-01

    Long coherence times and high fidelity control recently achieved in scalable superconducting circuits paved the way for the growing number of experimental studies of many-qubit quantum coherent phenomena in these devices. Albeit full implementation of quantum error correction and fault tolerant quantum computation remains a challenge the near term pre-error correction devices could allow new fundamental experiments despite inevitable accumulation of errors. One such open question foundational for quantum computing is achieving the so called quantum supremacy, an experimental demonstration of a computational task that takes polynomial time on the quantum computer whereas the best classical algorithm would require exponential time and/or resources. It is possible to formulate such a task for a quantum computer consisting of less than a 100 qubits. The computational task we consider is to provide approximate samples from a non-trivial quantum distribution. This is a generalization for the case of superconducting circuits of ideas behind boson sampling protocol for quantum optics introduced by Arkhipov and Aaronson. In this presentation we discuss a proof-of-principle demonstration of such a sampling task on a 9-qubit chain of superconducting gmon qubits developed by Google. We discuss theoretical analysis of the driven evolution of the device resulting in output approximating samples from a uniform distribution in the Hilbert space, a quantum chaotic state. We analyze quantum chaotic characteristics of the output of the circuit and the time required to generate a sufficiently complex quantum distribution. We demonstrate that the classical simulation of the sampling output requires exponential resources by connecting the task of calculating the output amplitudes to the sign problem of the Quantum Monte Carlo method. We also discuss the detailed theoretical modeling required to achieve high fidelity control and calibration of the multi-qubit unitary evolution in the device. We use a novel cross-entropy statistical metric as a figure of merit to verify the output and calibrate the device controls. Finally, we demonstrate the statistics of the wave function amplitudes generated on the 9-gmon chain and verify the quantum chaotic nature of the generated quantum distribution. This verifies the implementation of the quantum supremacy protocol.

  18. Qualitative and quantitative spectro-chemical analysis of dates using UV-pulsed laser induced breakdown spectroscopy and inductively coupled plasma mass spectrometry.

    PubMed

    Mehder, A O; Habibullah, Y B; Gondal, M A; Baig, Umair

    2016-08-01

    Laser Induced Breakdown Spectroscopy (LIBS) is demonstrated for the spectral analysis of nutritional and toxic elements present in several varieties of date fruit samples available in the Saudi Arabia market. The method analyzes the optical emission of a test sample when subjected to pulsed laser ablation. In this demonstration, our primary focus is on calcium (Ca) and magnesium (Mg), as nutritional elements, and on chromium (Cr), as a toxic element. The local thermodynamic equilibrium (LTE) condition was confirmed prior to the elemental characterization of date samples to ensure accuracy of the LIBS analysis. This was achieved by measuring parameters associated with the plasma, such as the electron temperature and the electron number density. These plasma parameters aid interpretation of processes such as ionization, dissociation, and excitation occurring in the plasma plume formed by ablating the date palm sample. The minimum detection limit was established from calibration curves that involved plotting the LIBS signal intensity as a function of standard date samples with known concentrations. The concentration of Ca and Mg detected in different varieties of date samples was between 187 and 515 and 35-196mgL(-1) respectively, while Cr concentration measured between 1.72 and 7.76mgL(-1). In order to optimize our LIBS system, we have studied how the LIBS signal intensity depends on the incident laser energy and the delay time. In order to validate our LIBS analysis results, standard techniques such as inductively coupled plasma mass spectrometry (ICP-MS) were also applied on an identical (duplicate) date samples as those used for the LIBS analysis. The LIBS results exhibit remarkable agreement with those obtained from the ICP-MS analysis. In addition, the finger print wavelengths of other elements present in date samples were also identified and are reported here, which has not been previously reported, to the best of our knowledge. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Simultaneous monitoring of faecal indicators and harmful algae using an in-situ autonomous sensor.

    PubMed

    Yamahara, K M; Demir-Hilton, E; Preston, C M; Marin, R; Pargett, D; Roman, B; Jensen, S; Birch, J M; Boehm, A B; Scholin, C A

    2015-08-01

    Faecal indicator bacteria (FIB) and harmful algal blooms (HABs) threaten the health and the economy of coastal communities worldwide. Emerging automated sampling technologies combined with molecular analytical techniques could enable rapid detection of micro-organisms in-situ, thereby improving resource management and public health decision-making. We evaluated this concept using a robotic device, the Environmental Sample Processor (ESP). The ESP automates in-situ sample collection, nucleic acid extraction and molecular analyses. Here, the ESP measured and reported concentrations of FIB (Enterococcus spp.), a microbial source-tracking marker (human-specific Bacteriodales) and a HAB species (Psuedo-nitzschia spp.) over a 45-day deployment on the Santa Cruz Municipal Wharf (Santa Cruz, CA, USA). Both FIB and HABs were enumerated from single in-situ collected water samples. The in-situ qPCR efficiencies ranged from 86% to 105%, while the limit of quantifications during the deployment was 10 copies reaction(-1) . No differences were observed in the concentrations of enterococci, the human-specific marker in Bacteroidales spp., and P. australis between in-situ collected sample and traditional hand sampling methods (P > 0·05). Analytical results were Internet-accessible within hours of sample collection, demonstrating the feasibility of same-day public notification of current water quality conditions. This study presents the first report of in-situ qPCR enumeration of both faecal indicators and harmful algal species in coastal marine waters. We utilize a robotic device for in-situ quantification of enterococci, the human-specific marker in Bacteriodales and Pseudo-nitzschia spp. from the same water samples collected and processed in-situ. The results demonstrate that rapid, in-situ monitoring can be utilized to identify and quantify multiple health-relevant micro-organisms important in water quality monitoring and that this monitoring can be used to inform same-day notifications. © 2015 The Society for Applied Microbiology.

  20. Microbial ecology measurement system

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The sensitivity and potential rapidity of the PIA test that was demonstrated during the feasibility study warranted continuing the effort to examine the possibility of adapting this test to an automated procedure that could be used during manned missions. The effort during this program has optimized the test conditions for two important respiratory pathogens, influenza virus and Mycoplasma pneumoniae, developed a laboratory model automated detection system, and investigated a group antigen concept for virus detection. Preliminary tests on the handling of oropharygeal clinical samples for PIA testing were performed using the adenovirus system. The results obtained indicated that the PIA signal is reduced in positive samples and is increased in negative samples. Treatment with cysteine appeared to reduce nonspecific agglutination in negative samples but did not maintain the signal in positive samples.

  1. Low power arcjet system spacecraft impacts

    NASA Technical Reports Server (NTRS)

    Pencil, Eric J.; Sarmiento, Charles J.; Lichtin, D. A.; Palchefsky, J. W.; Bogorad, A. L.

    1993-01-01

    Potential plume contamination of spacecraft surfaces was investigated by positioning spacecraft material samples relative to an arcjet thruster. Samples in the simulated solar array region were exposed to the cold gas arcjet plume for 40 hrs to address concerns about contamination by backstreaming diffusion pump oil. Except for one sample, no significant changes were measured in absorptance and emittance within experimental error. Concerns about surface property degradation due to electrostatic discharges led to the investigation of the discharge phenomenon of charged samples during arcjet ignition. Short duration exposure of charged samples demonstrated that potential differences are consistently and completely eliminated within the first second of exposure to a weakly ionized plume. The spark discharge mechanism was not the discharge phenomenon. The results suggest that the arcjet could act as a charge control device on spacecraft.

  2. Detection of caffeine in tea, instant coffee, green tea beverage, and soft drink by direct analysis in real time (DART) source coupled to single-quadrupole mass spectrometry.

    PubMed

    Wang, Lei; Zhao, Pengyue; Zhang, Fengzu; Bai, Aijuan; Pan, Canping

    2013-01-01

    Ambient ionization direct analysis in real time (DART) coupled to single-quadrupole MS (DART-MS) was evaluated for rapid detection of caffeine in commercial samples without chromatographic separation or sample preparation. Four commercial samples were examined: tea, instant coffee, green tea beverage, and soft drink. The response-related parameters were optimized for the DART temperature and MS fragmentor. Under optimal conditions, the molecular ion (M+H)+ was the major ion for identification of caffeine. The results showed that DART-MS is a promising tool for the quick analysis of important marker molecules in commercial samples. Furthermore, this system has demonstrated significant potential for high sample throughput and real-time analysis.

  3. Comparative value of blood and skin samples for diagnosis of spotted fever group rickettsial infection in model animals.

    PubMed

    Levin, Michael L; Snellgrove, Alyssa N; Zemtsova, Galina E

    2016-07-01

    The definitive diagnosis of spotted fever group (SFG) rickettsioses in humans is challenging due to the retrospective nature and cross reactivity of the serological methods and the absence of reliable and consistent samples for molecular diagnostics. Existing data indicate the transient character of bacteremia in experimentally infected animals. The ability of arthropod vectors to acquire rickettsial infection from the laboratory animals in the absence of systemic infection and known tropism of rickettsial agents to endothelial cells of peripheral blood vessels underline the importance of local infection and consequently the diagnostic potential of skin samples. In order to evaluate the diagnostic sensitivity of rickettsial DNA detection in blood and skin samples, we compared results of PCR testing in parallel samples collected from model laboratory animals infected with Rickettsia rickettsii, Rickettsia parkeri and Rickettsia slovaca-like agent at different time points after infection. Skin samples were collected from ears - away from the site of tick placement and without eschars. Overall, testing of skin samples resulted in a higher proportion of positive results than testing of blood samples. Presented data from model animals demonstrates that testing of skin samples from sites of rickettsial proliferation can provide definitive molecular diagnosis of up to 60-70% of tick-borne SFG rickettsial infections during the acute stage of illness. Detection of pathogen DNA in cutaneous samples is a valuable alternative to blood-PCR at least in model animals. Published by Elsevier GmbH.

  4. Forensic analysis of explosives using isotope ratio mass spectrometry (IRMS)--preliminary study on TATP and PETN.

    PubMed

    Benson, Sarah J; Lennard, Christopher J; Maynard, Philip; Hill, David M; Andrew, Anita S; Roux, Claude

    2009-06-01

    The application of isotopic techniques to investigations requiring the provision of evidence to a Court is limited. The objective of this research was to investigate the application of light stable isotopes and isotope ratio mass spectrometry (IRMS) to solve complex forensic cases by providing a level of discrimination not achievable utilising traditional forensic techniques. Due to the current threat of organic peroxide explosives, such as triacetone triperoxide (TATP), research was undertaken to determine the potential of IRMS to differentiate samples of TATP that had been manufactured utilising different starting materials and/or manufacturing processes. In addition, due to the prevalence of pentaerythritoltetranitrate (PETN) in detonators, detonating cord, and boosters, the potential of the IRMS technique to differentiate PETN samples from different sources was also investigated. Carbon isotope values were measured in fourteen TATP samples, with three definite groups appearing in the initial sample set based on the carbon data alone. Four additional TATP samples (in a second set of samples) were distinguishable utilising the carbon and hydrogen isotopic compositions individually, and also in combination with the oxygen isotope values. The 3D plot of the carbon, oxygen and hydrogen data demonstrated the clear discrimination of the four samples of TATP. The carbon and nitrogen isotope values measured from fifteen PETN samples, allowed samples from different sources to be readily discriminated. This paper demonstrates the successful application of IRMS to the analysis of explosives of forensic interest to assist in discriminating samples from different sources. This research represents a preliminary evaluation of the IRMS technique for the measurement of stable isotope values in TATP and PETN samples, and supports the dedication of resources for a full evaluation of this application in order to achieve Court reportable IRMS results.

  5. Evaluation of Sanofi Diagnostics Pasteur Chlamydia Microplate EIA shortened assay and comparison with cell culture and Syva Chlamydia MicroTrak II EIA in high- and low-risk populations.

    PubMed

    Chan, E L; Brandt, K; Horsman, G

    1995-11-01

    Seven hundred thirty-two female urogenital samples were collected for Chlamydia trachomatis testing by both the Sanofi Diagnostics Pasteur (Chaska, Minn.) Chlamydia Microplate EIA by the shortened protocol and the Syva (San Jose, Calif.) MicroTrak II EIA, and the results were compared with those obtained by cell culture. For the analysis of samples from female patients, the patients were divided into high- and low-risk categories. An additional 121 male urethral samples were collected and tested by the Sanofi Microplate EIA and cell culture; for the analysis of samples from male patients, the patients were divided into asymptomatic and symptomatic categories. All specimens positive by enzyme immunoassay (EIA) were confirmed by a blocking assay following the respective manufacturer's instructions. Specimens negative by EIA that fell within a gray zone 30% below the cutoff and negative cultures with one or more corresponding positive EIA results were tested further by cytocentrifugation and direct immunofluorescent assay. The overall sensitivity, specificity, positive predictive value, and negative predictive value for Syva versus culture were 94, 98.8, 85.5 and 99.6%, respectively. After resolution, the results were 94.5, 99.6, 94.5, and 99.6%, respectively. The parallel results for the Sanofi Microplate EIA versus culture were 94.0, 98.7, and 83.9, and 99.6%, respectively, and after being resolved, the results were 94.9, 100, 100, and 99.6%, respectively. In the small male population tested, the resolved results of the Sanofi Microplate EIA versus culture demonstrated sensitivity, specificity, positive predictive value, and negative predictive value of 100, 100, 100, and 100%, respectively. The present study demonstrated that the Sanofi Microplate EIA shortened protocol is highly sensitive and specific in comparison with cell culture and the Syva MicroTrak II EIA.

  6. Archaeological Reconnaissance Survey of Pool 10, Upper Mississippi River, Grant and Crawford Counties, Wisconsin, and Allamakee and Clayton Counties, Iowa

    DTIC Science & Technology

    1984-10-01

    buried archaeo- logical components during the Stage I sample provided useful - new information. At the same time , Stage I sample results demonstrated...by erosion directly related to maintenance and operation of the 9 foot navigation channel. At the same time , numerous sites of early to middle...Analysis. Publication No. 3, Chaco Center Studies. National Park Service and University of New Mexico. MALLAM, R. CLARK 1976 The Iowa Effigy Mound

  7. Rapid, Contactless and Non-Destructive Testing of Chemical Composition of Samples

    NASA Astrophysics Data System (ADS)

    Ivanov, O.; Vaseashta, A.; Stoychev, L.

    Our results demonstrate that a new effect can be induced in each solid in a wide spectral range of electromagnetic irradiation. In the present manuscript we prove experimentally that one of the possible applications of this effect is for an express contactless control of the chemical composition of a series of samples, in this case, coins. The method has wide applicability ranging from defense and homeland security to several applications requiring rapid and nondestructive identification of chemical composition.

  8. Ultrasonic imaging of textured alumina

    NASA Technical Reports Server (NTRS)

    Stang, David B.; Salem, Jonathan A.; Generazio, Edward R.

    1989-01-01

    Ultrasonic images representing the bulk attenuation and velocity of a set of alumina samples were obtained by a pulse-echo contact scanning technique. The samples were taken from larger bodies that were chemically similar but were processed by extrusion or isostatic processing. The crack growth resistance and fracture toughness of the larger bodies were found to vary with processing method and test orientation. The results presented here demonstrate that differences in texture that contribute to variations in structural performance can be revealed by analytic ultrasonic techniques.

  9. Comparison of narrative and expository writing in students with and without language-learning disabilities.

    PubMed

    Koutsoftas, Anthony D; Gray, Shelley

    2012-10-01

    Students with language-learning disabilities (LLD) demonstrate difficulties with written language, especially in the areas of productivity, complexity, and grammar. It is not clear how these deficits affect their performance on high-stakes tests, such as those required by the No Child Left Behind Act (U.S. Department of Education, 2002). This study used writing samples to compare how students with and without LLD scored on analytic writing measures that are typically used in writing research and on a more holistic measure of writing, the six-traits writing rubric (STWR; Education Northwest, 2006), which is used in high-stakes writing assessments. Fifty-six 4th and 5th graders with typical development (TD) or LLD produced 1 narrative and 1 expository writing sample. Measures of oral language ability and handwriting accuracy-speed were also obtained. The narrative and expository samples were scored using 5-6 separate analytic measures and 6 separate traits on the STWR. On narratives, the TD group scored significantly higher than the LLD group on 5 analytic measures and all 6 traits. Similarly, for expository, the TD group outscored the LLD group on 3 analytic measures and all 6 traits. Results demonstrate that the analytic scores of productivity, sentence complexity, and lexical diversity were correlated significantly with a higher overall score on the STWR for narrative writing samples only. Results of this study suggest that exclusive use of analytic scores to select treatment goals and document writing progress may not translate into increased scores on writing rubrics, particularly for expository writing samples.

  10. Friction Stir Processing of Stainless Steel for Ascertaining Its Superlative Performance in Bioimplant Applications.

    PubMed

    Perumal, G; Ayyagari, A; Chakrabarti, A; Kannan, D; Pati, S; Grewal, H S; Mukherjee, S; Singh, S; Arora, H S

    2017-10-25

    Substrate-cell interactions for a bioimplant are driven by substrate's surface characteristics. In addition, the performance of an implant and resistance to degradation are primarily governed by its surface properties. A bioimplant typically degrades by wear and corrosion in the physiological environment, resulting in metallosis. Surface engineering strategies for limiting degradation of implants and enhancing their performance may reduce or eliminate the need for implant removal surgeries and the associated cost. In the current study, we tailored the surface properties of stainless steel using submerged friction stir processing (FSP), a severe plastic deformation technique. FSP resulted in significant microstructural refinement from 22 μm grain size for the as-received alloy to 0.8 μm grain size for the processed sample with increase in hardness by nearly 1.5 times. The wear and corrosion behavior of the processed alloy was evaluated in simulated body fluid. The processed sample demonstrated remarkable improvement in both wear and corrosion resistance, which is explained by surface strengthening and formation of a highly stable passive layer. The methylthiazol tetrazolium assay demonstrated that the processed sample is better in supporting cell attachment, proliferation with minimal toxicity, and hemolysis. The athrombogenic characteristic of the as-received and processed samples was evaluated by fibrinogen adsorption and platelet adhesion via the enzyme-linked immunosorbent assay and lactate dehydrogenase assay, respectively. The processed sample showed less platelet and fibrinogen adhesion compared with the as-received alloy, signifying its high thromboresistance. The current study suggests friction stir processing to be a versatile toolbox for enhancing the performance and reliability of currently used bioimplant materials.

  11. Molecular method for detection of total coliforms in drinking water samples.

    PubMed

    Maheux, Andrée F; Boudreau, Dominique K; Bisson, Marc-Antoine; Dion-Dupont, Vanessa; Bouchard, Sébastien; Nkuranga, Martine; Bergeron, Michel G; Rodriguez, Manuel J

    2014-07-01

    This work demonstrates the ability of a bacterial concentration and recovery procedure combined with three different PCR assays targeting the lacZ, wecG, and 16S rRNA genes, respectively, to detect the presence of total coliforms in 100-ml samples of potable water (presence/absence test). PCR assays were first compared to the culture-based Colilert and MI agar methods to determine their ability to detect 147 coliform strains representing 76 species of Enterobacteriaceae encountered in fecal and environmental settings. Results showed that 86 (58.5%) and 109 (74.1%) strains yielded a positive signal with Colilert and MI agar methods, respectively, whereas the lacZ, wecG, and 16S rRNA PCR assays detected 133 (90.5%), 111 (75.5%), and 146 (99.3%) of the 147 total coliform strains tested. These assays were then assessed by testing 122 well water samples collected in the Québec City region of Canada. Results showed that 97 (79.5%) of the samples tested by culture-based methods and 95 (77.9%), 82 (67.2%), and 98 (80.3%) of samples tested using PCR-based methods contained total coliforms, respectively. Consequently, despite the high genetic variability of the total coliform group, this study demonstrated that it is possible to use molecular assays to detect total coliforms in potable water: the 16S rRNA molecular assay was shown to be as efficient as recommended culture-based methods. This assay might be used in combination with an Escherichia coli molecular assay to assess drinking water quality. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  12. Molecular Method for Detection of Total Coliforms in Drinking Water Samples

    PubMed Central

    Boudreau, Dominique K.; Bisson, Marc-Antoine; Dion-Dupont, Vanessa; Bouchard, Sébastien; Nkuranga, Martine; Bergeron, Michel G.; Rodriguez, Manuel J.

    2014-01-01

    This work demonstrates the ability of a bacterial concentration and recovery procedure combined with three different PCR assays targeting the lacZ, wecG, and 16S rRNA genes, respectively, to detect the presence of total coliforms in 100-ml samples of potable water (presence/absence test). PCR assays were first compared to the culture-based Colilert and MI agar methods to determine their ability to detect 147 coliform strains representing 76 species of Enterobacteriaceae encountered in fecal and environmental settings. Results showed that 86 (58.5%) and 109 (74.1%) strains yielded a positive signal with Colilert and MI agar methods, respectively, whereas the lacZ, wecG, and 16S rRNA PCR assays detected 133 (90.5%), 111 (75.5%), and 146 (99.3%) of the 147 total coliform strains tested. These assays were then assessed by testing 122 well water samples collected in the Québec City region of Canada. Results showed that 97 (79.5%) of the samples tested by culture-based methods and 95 (77.9%), 82 (67.2%), and 98 (80.3%) of samples tested using PCR-based methods contained total coliforms, respectively. Consequently, despite the high genetic variability of the total coliform group, this study demonstrated that it is possible to use molecular assays to detect total coliforms in potable water: the 16S rRNA molecular assay was shown to be as efficient as recommended culture-based methods. This assay might be used in combination with an Escherichia coli molecular assay to assess drinking water quality. PMID:24771030

  13. The demonstration of an advanced cyclone coal combustor, with internal sulfur, nitrogen, and ash control for the conversion of a 23 MMBTU/hour oil fired boiler to pulverized coal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zauderer, B.; Fleming, E.S.

    1991-08-30

    This work contains to the final report of the demonstration of an advanced cyclone coal combustor. Titles include: Chronological Description of the Clean Coal Project Tests,'' Statistical Analysis of Operating Data for the Coal Tech Combustor,'' Photographic History of the Project,'' Results of Slag Analysis by PA DER Module 1 Procedure,'' Properties of the Coals Limestone Used in the Test Effort,'' Results of the Solid Waste Sampling Performed on the Coal Tech Combustor by an Independent Contractor During the February 1990 Tests.'' (VC)

  14. The Deaf Acculturation Scale (DAS): Development and Validation of a 58-Item Measure

    PubMed Central

    Maxwell-McCaw, Deborah; Zea, Maria Cecilia

    2011-01-01

    This study involved the development and validation of the Deaf Acculturation Scale (DAS), a new measure of cultural identity for Deaf and hard-of-hearing (hh) populations. Data for this study were collected online and involved a nation-wide sample of 3,070 deaf/hh individuals. Results indicated strong internal reliabilities for all the subscales, and construct validity was established by demonstrating that the DAS could discriminate groups based on parental hearing status, school background, and use of self-labels. Construct validity was further demonstrated through factorial analyses, and findings resulted in a final 58-item measure. Directions for future research are discussed. PMID:21263041

  15. Perceived Risk as a Moderator of the Effectiveness of Framed HIV Test Promotion Messages Among Women: A Randomized Controlled Trial

    PubMed Central

    Hull, Shawnika J

    2014-01-01

    Objective Researchers argue that gain framed messages should be more effective for prevention behaviors while loss frames should be more effective for detection behaviors (Rothman & Salovey, 1997). Evidence for this taxonomy has been mixed. This study examines whether the effects of gain and loss framed messages on HIV testing intentions is moderated by perceived risk of a positive result. Methods This experiment was conducted on-line and utilizes a single factor (frame: gain/loss) between subjects design, with a separate HIV test promotion control and a no message control to examine whether perceived risk of a positive test result moderates the effects of framed messages on intentions to seek an HIV test in the next 3 months. The sample (N=1052; age M = 22, SD = 2.22), recruited through Survey Sampling International, included 51% Black women (49% White women). Results HIV test promotion messages were more effective than no message but there were no other main effects for condition. Results also demonstrate a significant interaction between message frame and perceived risk, which is mediated through elaborative processing of the message. The interaction demonstrated an advantage for the loss framed message among women with some perceived risk and an advantage for the gain framed message among women with low perceived risk. Conclusion Results imply that the prevention/detection function of the behavior may be an inadequate distinction in the consideration of the effectiveness of framed messages promoting HIV testing. Rather, this study demonstrates that risk perceptions are an important moderator of framing effects. PMID:21767018

  16. The influence of solvent processing on polyester bioabsorbable polymers.

    PubMed

    Manson, Joanne; Dixon, Dorian

    2012-01-01

    Solvent-based methods are commonly employed for the production of polyester-based samples and coatings in both medical device production and research. The influence of solvent casting and subsequent drying time was studied using thermal analysis, spectroscopy and weight measurement for four grades of 50 : 50 poly(lactic-co-glycolic acid) (PLGA) produced by using chloroform, dichloromethane, and acetone. The results demonstrate that solvent choice and PLGA molecular weight are critical factors in terms of solvent removal rate and maintaining sample integrity, respectively. The protocols widely employed result in high levels of residual solvent and a new protocol is presented together with solutions to commonly encountered problems.

  17. Psychometric properties of Frustration Discomfort Scale in a Turkish sample.

    PubMed

    Ozer, Bilge Uzun; Demir, Ayhan; Harrington, Neil

    2012-08-01

    The present study assessed the psychometric properties of the Frustration Discomfort Scale for Turkish college students. The Frustration Discomfort Scale (FDS), Procrastination Assessment Scale-Student, and Rosenberg Self-Esteem Scale were administered to a sample of 171 (98 women, 73 men) Turkish college students. The results of the confirmatory factor analysis yielded fit index values demonstrating viability of the four-dimensional solution as in the original. Findings also revealed that, as predicted, the Discomfort Intolerance subscale of Turkish FDS was most strongly correlated with procrastination. Overall results provided evidence for the factor validity and reliability of the Turkish version of the scale for use in a Turkish population.

  18. A loop-mediated isothermal amplification method for a differential identification of Taenia tapeworms from human: application to a field survey.

    PubMed

    Nkouawa, Agathe; Sako, Yasuhito; Li, Tiaoying; Chen, Xingwang; Nakao, Minoru; Yanagida, Tetsuya; Okamoto, Munehiro; Giraudoux, Patrick; Raoul, Francis; Nakaya, Kazuhiro; Xiao, Ning; Qiu, Jiamin; Qiu, Dongchuan; Craig, Philip S; Ito, Akira

    2012-12-01

    In this study, we applied a loop-mediated isothermal amplification method for identification of human Taenia tapeworms in Tibetan communities in Sichuan, China. Out of 51 proglottids recovered from 35 carriers, 9, 1, and 41 samples were identified as Taenia solium, Taenia asiatica and Taenia saginata, respectively. Same results were obtained afterwards in the laboratory, except one sample. These results demonstrated that the LAMP method enabled rapid identification of parasites in the field surveys, which suggested that this method would contribute to the control of Taenia infections in endemic areas. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Carbon-13 and proton nuclear magnetic resonance analysis of shale-derived refinery products and jet fuels and of experimental referee broadened-specification jet fuels

    NASA Technical Reports Server (NTRS)

    Dalling, D. K.; Bailey, B. K.; Pugmire, R. J.

    1984-01-01

    A proton and carbon-13 nuclear magnetic resonance (NMR) study was conducted of Ashland shale oil refinery products, experimental referee broadened-specification jet fuels, and of related isoprenoid model compounds. Supercritical fluid chromatography techniques using carbon dioxide were developed on a preparative scale, so that samples could be quantitatively separated into saturates and aromatic fractions for study by NMR. An optimized average parameter treatment was developed, and the NMR results were analyzed in terms of the resulting average parameters; formulation of model mixtures was demonstrated. Application of novel spectroscopic techniques to fuel samples was investigated.

  20. DEVELOPMENT OF APPAREL AND FOOTWEAR FROM RENEWABLE SOURCES (PHASE II)

    EPA Science Inventory

    At the end of this project, we will have the demonstration package including samples of all the bio-based renewable materials used in the design, the apparel and footwear prototypes, and the evaluation results. This project will be integrated into required textiles course for ...

  1. Histological relationship of Phytobia setosa to Acer saccharum

    Treesearch

    Robert Gregory; William Wallner

    1979-01-01

    The maple cambium miner, Phytobia setosa (Loew), attacks Acer spp., producing ray flecks which result in degrade in face veneer and furniture wood. Samples from infested sugar maple, Acer saccharum Marsh, trees demonstrated that while mines passed close to the vascular cambium the initial cells were not...

  2. Polytomous Rasch Models in Counseling Assessment

    ERIC Educational Resources Information Center

    Willse, John T.

    2017-01-01

    This article provides a brief introduction to the Rasch model. Motivation for using Rasch analyses is provided. Important Rasch model concepts and key aspects of result interpretation are introduced, with major points reinforced using a simulation demonstration. Concrete guidelines are provided regarding sample size and the evaluation of items.

  3. Enhancing Employee Skills.

    ERIC Educational Resources Information Center

    1999

    This document contains four symposium papers on enhancing employee skills. "The Effect of Study Skills Training Intervention on United States Air Force Aeromedical Apprentices" (John C. Griffith) demonstrates how study skills intervention resulted in a significant increase in the end-of-course scores of a sample of 90 randomly selected Air Force…

  4. Synthesis and properties of shape memory polyurethanes generated from schiff-base chain extender containing benzoyl and pyridyl rings

    PubMed Central

    Weng, Neng-Chiao; Wu, Chih-Fu; Tsen, Wen-Chin; Wu, Cheng-Lung; Suen, Maw-Cherng

    2018-01-01

    Abstract In this study, 4,4′-diphenylmethane diisocyanate and polytetramethylene glycol were used to prepare a prepolymer; N,N′-bis(4-hydroxybenzylidene)-2,6-diaminopyridine (BHBP) was used as a chain extender; and these elements were combined to prepare a novel polyurethane, BHBP/PU. Gel permeation chromatography revealed that the molecular weight of the BHBP/PU samples increased as the BHBP content was increased. Fourier transform infrared spectroscopy demonstrated that high BHBP content facilitated strong hydrogen bonding in the samples. Differential thermogravimetry indicated that the initial decomposition temperature of BHBP/PU-3 was approximately 10 °C higher than that of BHBP/PU-1. Differential scanning calorimetry and dynamic mechanical analysis revealed that increasing the BHBP content substantially increased both the glass transition and dynamic glass transition temperatures of the BHBP/PU samples. The tensile strengths of BHBP/PU-1, BHBP/PU-2, and BHBP/PU-3 were 7.7, 10.9, and 21.6 MPa, respectively, with corresponding Young’s moduli of 0.7, 1.9, and 3.3 MPa. These results demonstrated that both the tensile strength and Young’s modulus of the BHBP/PU samples increased as the BHBP content was increased. Moreover, the BHBP/PU samples exhibited excellent shape recovery of >90%. PMID:29706848

  5. Lensless digital holography with diffuse illumination through a pseudo-random phase mask.

    PubMed

    Bernet, Stefan; Harm, Walter; Jesacher, Alexander; Ritsch-Marte, Monika

    2011-12-05

    Microscopic imaging with a setup consisting of a pseudo-random phase mask, and an open CMOS camera, without an imaging objective, is demonstrated. The pseudo random phase mask acts as a diffuser for an incoming laser beam, scattering a speckle pattern to a CMOS chip, which is recorded once as a reference. A sample which is afterwards inserted somewhere in the optical beam path changes the speckle pattern. A single (non-iterative) image processing step, comparing the modified speckle pattern with the previously recorded one, generates a sharp image of the sample. After a first calibration the method works in real-time and allows quantitative imaging of complex (amplitude and phase) samples in an extended three-dimensional volume. Since no lenses are used, the method is free from lens abberations. Compared to standard inline holography the diffuse sample illumination improves the axial sectioning capability by increasing the effective numerical aperture in the illumination path, and it suppresses the undesired so-called twin images. For demonstration, a high resolution spatial light modulator (SLM) is programmed to act as the pseudo-random phase mask. We show experimental results, imaging microscopic biological samples, e.g. insects, within an extended volume at a distance of 15 cm with a transverse and longitudinal resolution of about 60 μm and 400 μm, respectively.

  6. The vector homology problem in diagnostic nucleic acid hybridization of clinical specimens.

    PubMed Central

    Ambinder, R F; Charache, P; Staal, S; Wright, P; Forman, M; Hayward, S D; Hayward, G S

    1986-01-01

    Nucleic acid hybridization techniques using cloned probes are finding application in assays of clinical specimens in research and diagnostic laboratories. The probes that we and others have used are recombinant plasmids composed of viral inserts and bacterial plasmid vectors such as pBR322. We suspected that there was material homologous to pBR322 present in many clinical samples. because hybridization occurred in samples which lacked evidence of virus by other techniques. If the presence of this vector-homologous material was unrecognized, hybridization in the test sample might erroneously be interpreted as indicating the presence of viral sequences. In this paper we demonstrate specific hybridization of labeled pBR322 DNA with DNA from various clinical samples. Evidence is presented that nonspecific probe trapping could not account for this phenomenon. In mixing experiments, it is shown that contamination of clinical samples with bacteria would explain such a result. Approaches tested to circumvent this problem included the use of isolated insert probes, alternate cloning vectors, and cold competitor pBR322 DNA in prehybridization and hybridization mixes. None proved entirely satisfactory. We therefore emphasize that it is essential that all hybridization detection systems use a control probe of the vector alone in order to demonstrate the absence of material with vector homology in the specimen tested. Images PMID:3013928

  7. Evaluation of a gas chromatography method for azelaic acid determination in selected biological samples.

    PubMed

    Garelnabi, Mahdi; Litvinov, Dmitry; Parthasarathy, Sampath

    2010-09-01

    Azelaic acid (AzA) is the best known dicarboxilic acid to have pharmaceutical benefits and clinical applications and also to be associated with some diseases pathophysiology. We extracted and methylesterified AzA and determined its concentration in human plasma obtained from healthy individuals and also in mice fed AzA containing diet for three months. AzA was detected in Gas Chromatography (GC) and confirmed by Liquid chromatography mass spectrometry (LCMS), and gas chromatography mass spectrometry (GCMC). Our results have shown that AzA can be determined efficiently in selected biological samples by GC method with 1nM limit of detection (LoD) and the limit of quantification (LoQ); was established at 50nM. Analytical Sensitivity as assayed by hexane demonstrated an analytical sensitivity at 0.050nM. The method has demonstrated 8-10% CV batch repeatability across the sample types and 13-18.9% CV for the Within-Lab Precision analysis. The method has shown that AzA can efficiently be recovered from various sample preparation including liver tissue homogenate (95%) and human plasma (97%). Because of its simplicity and lower limit of quantification, the present method provides a useful tool for determining AzA in various biological sample preparations.

  8. Traceability of sulfonamide antibiotic treatment by immunochemical analysis of farm animal hair samples.

    PubMed

    Adrian, Javier; Gratacós-Cubarsí, Marta; Sánchez-Baeza, Francisco; Garcia Regueiro, Jose-Antonio; Castellari, Massimo; Marco, M-Pilar

    2009-10-01

    The use of hair to trace use of unauthorized substances, therapeutic agents, or their misuse is becoming very attractive since residues can be detected for a long time after treatment. For this purpose, an indirect enzyme-linked immunosorbent assay (ELISA) has been evaluated for its capability to trace sulfonamide antibiotic treatment by analyzing cattle and pig hair samples. Pigmented and nonpigmented hair samples from control and sulfamethazine (SMZ)-treated pigs and calves were collected, extracted under different alkaline conditions, and analyzed by ELISA after just diluting the extracts with the assay buffer. Data analysis following the European recommendations for screening methods demonstrates that the ELISA can detect SMZ in hair samples with a limit of detection (90% of the zero dose (IC(90))) between 30 and 75 ng g(-1). The same samples have been analyzed by HPLC after a dual solid-phase extraction. The ELISA results matched very well those obtained by the chromatographic method, demonstrating that the immunochemical method can be used as a screening tool to trace animal treatments. Between the benefits of this method are the possibility to directly analyze hair extracts with sufficient detectability and its high-throughput capability. Preliminary validation data are reported using an experimental approach inspired on the Commission Decision 2002/657/EC criteria for screening methods.

  9. Liquid Microjunction Surface Sampling Probe Electrospray Mass Spectrometry for Detection of Drugs and Metabolites in Thin Tissue Sections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Berkel, Gary J; Kertesz, Vilmos; Koeplinger, Kenneth A.

    2008-01-01

    A self-aspirating, liquid micro-junction surface sampling probe/electrospray emitter mass spectrometry system was demonstrated for use in the direct analysis of spotted and dosed drugs and their metabolites in thin tissue sections. Proof-of-principle sampling and analysis directly from tissue without the need for sample preparation was demonstrated first by raster scanning a region on a section of rat liver onto which reserpine was spotted. The mass spectral signal from selected reaction monitoring was used to develop a chemical image of the spotted drug on the tissue. The probe was also used to selectively spot sample areas of sagittal whole mouse bodymore » tissue sections that had been dosed orally (90 mg/kg) with R,S-sulforaphane 3 hrs prior to sacrifice. Sulforaphane and its glutathione and N-acetyl cysteine conjugates were monitored with selected reaction monitoring and detected in the stomach and various other tissues from the dosed mouse. No signal for these species was observed in the tissue from a control mouse. The same dosed tissue section was used to illustrate the possibility of obtaining a line scan across the whole body section. In total these results illustrate the potential for rapid screening of the distribution of drugs and metabolites in tissue sections with the micro-liquid junction surface sampling probe/electrospray mass spectrometry approach.« less

  10. A synchrotron-based local computed tomography combined with data-constrained modelling approach for quantitative analysis of anthracite coal microstructure

    PubMed Central

    Chen, Wen Hao; Yang, Sam Y. S.; Xiao, Ti Qiao; Mayo, Sherry C.; Wang, Yu Dan; Wang, Hai Peng

    2014-01-01

    Quantifying three-dimensional spatial distributions of pores and material compositions in samples is a key materials characterization challenge, particularly in samples where compositions are distributed across a range of length scales, and where such compositions have similar X-ray absorption properties, such as in coal. Consequently, obtaining detailed information within sub-regions of a multi-length-scale sample by conventional approaches may not provide the resolution and level of detail one might desire. Herein, an approach for quantitative high-definition determination of material compositions from X-ray local computed tomography combined with a data-constrained modelling method is proposed. The approach is capable of dramatically improving the spatial resolution and enabling finer details within a region of interest of a sample larger than the field of view to be revealed than by using conventional techniques. A coal sample containing distributions of porosity and several mineral compositions is employed to demonstrate the approach. The optimal experimental parameters are pre-analyzed. The quantitative results demonstrated that the approach can reveal significantly finer details of compositional distributions in the sample region of interest. The elevated spatial resolution is crucial for coal-bed methane reservoir evaluation and understanding the transformation of the minerals during coal processing. The method is generic and can be applied for three-dimensional compositional characterization of other materials. PMID:24763649

  11. Improving detection probabilities for pests in stored grain.

    PubMed

    Elmouttie, David; Kiermeier, Andreas; Hamilton, Grant

    2010-12-01

    The presence of insects in stored grain is a significant problem for grain farmers, bulk grain handlers and distributors worldwide. Inspection of bulk grain commodities is essential to detect pests and thereby to reduce the risk of their presence in exported goods. It has been well documented that insect pests cluster in response to factors such as microclimatic conditions within bulk grain. Statistical sampling methodologies for grain, however, have typically considered pests and pathogens to be homogeneously distributed throughout grain commodities. In this paper, a sampling methodology is demonstrated that accounts for the heterogeneous distribution of insects in bulk grain. It is shown that failure to account for the heterogeneous distribution of pests may lead to overestimates of the capacity for a sampling programme to detect insects in bulk grain. The results indicate the importance of the proportion of grain that is infested in addition to the density of pests within the infested grain. It is also demonstrated that the probability of detecting pests in bulk grain increases as the number of subsamples increases, even when the total volume or mass of grain sampled remains constant. This study underlines the importance of considering an appropriate biological model when developing sampling methodologies for insect pests. Accounting for a heterogeneous distribution of pests leads to a considerable improvement in the detection of pests over traditional sampling models. Copyright © 2010 Society of Chemical Industry.

  12. Evaluation of non-extracted genital swabs for real-time HSV PCR.

    PubMed

    Miari, Victoria F; Wall, Gavin R; Clark, Duncan A

    2015-01-01

    Nucleic acid extraction of clinical samples is accepted as a key requirement in molecular diagnostics. At Barts Health NHS Trust, swabs taken from patients with clinical suspicion of HSV infection were routinely extracted on the Qiagen MDx BioRobot prior to testing with a real-time triplex PCR for HSV1, HSV2, and VZV. The aim of this study was to adapt an existing HSV1/HSV2/VZV real-time PCR by replacing VZV with phocine herpesvirus 1 (PhHV) as an internal control (IC) and evaluate whether this adapted assay required the nucleic acid extraction step for predominantly genital swabs. First 313 non-extracted and extracted swabs were tested in parallel with the existing triplex HSV1/HSV2/VZV real-time PCR. The second stage involved testing 176 non-extracted swabs using a triplex real-time PCR for HSV1, HSV2, and PhHV and comparing the results with the samples extracted and tested by the original triplex assay. The results correlated well when the existing assay was used, with only three non-extracted samples that would have been reported as negative compared to the extracted sample result (Cq s 33, 39, 35-two samples HSV1, one sample HSV2). In the evaluation using the adapted assay containing the IC, two of 176 samples were discordant, where a HSV negative non-extracted sample result would have been reported differently to the extracted sample result (Cq s 32, 33-both HSV1). This study demonstrated that it is feasible to test non-extracted swabs for HSV in a real-time PCR that includes an IC. J. Med. Virol. 87: 125-129, 2015. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  13. Alpha Matting with KL-Divergence Based Sparse Sampling.

    PubMed

    Karacan, Levent; Erdem, Aykut; Erdem, Erkut

    2017-06-22

    In this paper, we present a new sampling-based alpha matting approach for the accurate estimation of foreground and background layers of an image. Previous sampling-based methods typically rely on certain heuristics in collecting representative samples from known regions, and thus their performance deteriorates if the underlying assumptions are not satisfied. To alleviate this, we take an entirely new approach and formulate sampling as a sparse subset selection problem where we propose to pick a small set of candidate samples that best explains the unknown pixels. Moreover, we describe a new dissimilarity measure for comparing two samples which is based on KLdivergence between the distributions of features extracted in the vicinity of the samples. The proposed framework is general and could be easily extended to video matting by additionally taking temporal information into account in the sampling process. Evaluation on standard benchmark datasets for image and video matting demonstrates that our approach provides more accurate results compared to the state-of-the-art methods.

  14. [Local Regression Algorithm Based on Net Analyte Signal and Its Application in Near Infrared Spectral Analysis].

    PubMed

    Zhang, Hong-guang; Lu, Jian-gang

    2016-02-01

    Abstract To overcome the problems of significant difference among samples and nonlinearity between the property and spectra of samples in spectral quantitative analysis, a local regression algorithm is proposed in this paper. In this algorithm, net signal analysis method(NAS) was firstly used to obtain the net analyte signal of the calibration samples and unknown samples, then the Euclidean distance between net analyte signal of the sample and net analyte signal of calibration samples was calculated and utilized as similarity index. According to the defined similarity index, the local calibration sets were individually selected for each unknown sample. Finally, a local PLS regression model was built on each local calibration sets for each unknown sample. The proposed method was applied to a set of near infrared spectra of meat samples. The results demonstrate that the prediction precision and model complexity of the proposed method are superior to global PLS regression method and conventional local regression algorithm based on spectral Euclidean distance.

  15. Investigation on thermal oxidative aging of nitrile rubber (NBR) O-rings under compression stress

    NASA Astrophysics Data System (ADS)

    Liu, X. R.; Zhang, W. F.; Lou, W. T.; Huang, Y. X.; Dai, W.

    2017-11-01

    The degradation behaviors of nitrile rubber O-rings exposure to air under compression were investigated at three elevated temperatures. The physical and mechanical properties of the aging samples before and after exposure at selected time were studied by measuring weight loss, tensile strength and elongation at break. The Attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy and fracture morphology were used to reveal the microstructural changes of the aging samples. The results indicate that the weight decreased with exposure time and temperature. Based on the results of the crosslinking density, the crosslinking predominates during the most of aging process. The significant changes in tensile strength and elongation at break also indicate the severe degradation in air. The fracture morphology results show that the fracture surface after 64 days of exposure to air turns rough and present defects. The ATR-FTIR results demonstrate that the hydroxyl groups were formed for the samples aged in air.

  16. Analysis of human tissues by total reflection X-ray fluorescence. Application of chemometrics for diagnostic cancer recognition

    NASA Astrophysics Data System (ADS)

    Benninghoff, L.; von Czarnowski, D.; Denkhaus, E.; Lemke, K.

    1997-07-01

    For the determination of trace element distributions of more than 20 elements in malignant and normal tissues of the human colon, tissue samples (approx. 400 mg wet weight) were digested with 3 ml of nitric acid (sub-boiled quality) by use of an autoclave system. The accuracy of measurements has been investigated by using certified materials. The analytical results were evaluated by using a spreadsheet program to give an overview of the element distribution in cancerous samples and in normal colon tissues. A further application, cluster analysis of the analytical results, was introduced to demonstrate the possibility of classification for cancer diagnosis. To confirm the results of cluster analysis, multivariate three-way principal component analysis was performed. Additionally, microtome frozen sections (10 μm) were prepared from the same tissue samples to compare the analytical results, i.e. the mass fractions of elements, according to the preparation method and to exclude systematic errors depending on the inhomogeneity of the tissues.

  17. Synchronous separation, seaming, sealing and sterilization (S4) using brazing for sample containerization and planetary protection

    NASA Astrophysics Data System (ADS)

    Bar-Cohen, Yoseph; Badescu, Mircea; Bao, Xiaoqi; Lee, Hyeong Jae; Sherrit, Stewart; Freeman, David; Campos, Sergio

    2017-04-01

    The potential return of samples back to Earth in a future NASA mission would require protection of our planet from the risk of bringing uncontrolled biological materials back with the samples. In order to ensure this does not happen, it would be necessary to "break the chain of contact (BTC)", where any material reaching Earth would have to be inside a container that is sealed with extremely high confidence. Therefore, it would be necessary to contain the acquired samples and destroy any potential biological materials that may contaminate the external surface of their container while protecting the sample itself for further analysis. A novel synchronous separation, seaming, sealing and sterilization (S4) process for sample containerization and planetary protection has been conceived and demonstrated. A prototype double wall container with inner and outer shells and Earth clean interstitial space was used for this demonstration. In a potential future mission, the double wall container would be split into two halves and prepared on Earth, while the potential on-orbit execution would consist of inserting the sample into one of the halves and then mating to the other half and brazing. The use of brazing material that melts at temperatures higher than 500°C would assure sterilization of the exposed areas since all carbon bonds are broken at this temperature. The process would be executed in two-steps, Step-1: the double wall container halves would be fabricated and brazed on Earth; and Step-2: the containerization and sterilization process would be executed on-orbit. To prevent potential jamming during the process of mating the two halves of the double wall container and the extraction of the brazed inner container, a cone-within-cone approach has been conceived and demonstrated. The results of this study will be described and discussed.

  18. A psychometric study of the Test of Everyday Attention for Children in the Chinese setting.

    PubMed

    Chan, Raymond C K; Wang, Li; Ye, Jiawen; Leung, Winnie W Y; Mok, Monica Y K

    2008-07-01

    To explore the psychometric properties of the Test of Everyday Attention for Children (TEA-Ch) in the context of a Chinese setting. Confirmatory factor analysis was conducted to examine the construct validity of the Chinese version of the TEA-Ch among a group of 232 children without attention deficit hyperactivity disorder (ADHD). Test-retest reliability was tested on a random sub-sample of 20 children at a 4-week interval. Clinical discrimination was also examined by comparing children with and without ADHD (22 in each group) on the performances of the TEA-Ch. The current Chinese sample demonstrated a three-factor solution for attentional performance among children without ADHD, namely selective attention, executive control/switch, and sustained attention (chi(2)(24)=34.56; RMSEA=.044; p=.075). Moreover, the whole test demonstrated acceptable test-retest reliability at a 4-week interval among a small sub-sample. Children with ADHD performed significantly more poorly than healthy controls in most of the subtests of the TEA-Ch. The results of the present study demonstrate that the test items remain useful in China, a culture very different from that in which the test originated. Finally, the TEA-Ch also presents several advantages when compared to other conventional objective measures of attention.

  19. UV Raman imaging--a promising tool for astrobiology: comparative Raman studies with different excitation wavelengths on SNC Martian meteorites.

    PubMed

    Frosch, Torsten; Tarcea, Nicolae; Schmitt, Michael; Thiele, Hans; Langenhorst, Falko; Popp, Jürgen

    2007-02-01

    The great capabilities of UV Raman imaging have been demonstrated on the three Martian meteorites: Sayh al Uhaymir, Dar al Gani, and Zagami. Raman spectra without disturbing fluorescence and with high signal-to-noise-ratios and full of spectral features were derived. This result is of utmost importance for the development of powerful instruments for space missions. By point scanning the surfaces of the meteorite samples, it was possible for the first time to construct UV-Raman images out of the array of Raman spectra. Deep-UV Raman images are to the best of our knowledge presented for the first time. The images were used for a discussion of the chemical-mineralogical composition and texture of the meteorite surfaces. Comparative Raman studies applying visible and NIR Raman excitation wavelengths demonstrate a much better performance for UV Raman excitation. This comparative study of different Raman excitation wavelengths at the same sample spots was done by constructing a versatile, robust sample holder with a fixed micro-raster. The overall advantages of UV resonance Raman spectroscopy in terms of sensitivity and selectivity are demonstrated and discussed. Finally the application of this new technique for a UV Raman instrument for envisaged astrobiological focused space missions is suggested.

  20. Concentration gradient along the scala tympani after local application of gentamicin to the round window membrane.

    PubMed

    Plontke, Stefan K; Mynatt, Robert; Gill, Ruth M; Borgmann, Stefan; Salt, Alec N

    2007-07-01

    The distribution of gentamicin along the fluid spaces of the cochlea after local applications has never previously been demonstrated. Computer simulations have predicted that significant basal-apical concentration gradients might be expected, and histologic studies indicate that hair cell damage is greater at the base than at the apex after local gentamicin application. In the present study, gradients of gentamicin along the cochlea were measured. A recently developed method of sampling perilymph from the cochlear apex of guinea pigs was used in which the samples represent fluid originating from different regions along the scala tympani. Gentamicin concentration was determined in sequential apical samples that were taken after up to 3 hours of local application to the round window niche. Substantial gradients of gentamicin along the length of the scala tympani were demonstrated and quantified, averaging more than 4,000 times greater concentration at the base compared with the apex at the time of sampling. Peak concentrations and gradients for gentamicin varied considerably between animals, likely resulting from variations in round window membrane permeability and rates of perilymph flow. The large gradients for gentamicin demonstrated here in guinea pigs account for how it is possible to suppress vestibular function in some patients with a local application of gentamicin without damaging auditory function. Variations in round window membrane permeability and in perilymph flow could account for why hearing losses are observed in some patients.

  1. Use of Whatman-41 filters in air quality sampling networks (with applications to elemental analysis)

    NASA Technical Reports Server (NTRS)

    Neustadter, H. E.; Sidik, S. M.; King, R. B.; Fordyce, J. S.; Burr, J. C.

    1974-01-01

    The operation of a 16-site parallel high volume air sampling network with glass fiber filters on one unit and Whatman-41 filters on the other is reported. The network data and data from several other experiments indicate that (1) Sampler-to-sampler and filter-to-filter variabilities are small; (2) hygroscopic affinity of Whatman-41 filters need not introduce errors; and (3) suspended particulate samples from glass fiber filters averaged slightly, but not statistically significantly, higher than from Whatman-41-filters. The results obtained demonstrate the practicability of Whatman-41 filters for air quality monitoring and elemental analysis.

  2. Probabilistic Design of a Mars Sample Return Earth Entry Vehicle Thermal Protection System

    NASA Technical Reports Server (NTRS)

    Dec, John A.; Mitcheltree, Robert A.

    2002-01-01

    The driving requirement for design of a Mars Sample Return mission is to assure containment of the returned samples. Designing to, and demonstrating compliance with, such a requirement requires physics based tools that establish the relationship between engineer's sizing margins and probabilities of failure. The traditional method of determining margins on ablative thermal protection systems, while conservative, provides little insight into the actual probability of an over-temperature during flight. The objective of this paper is to describe a new methodology for establishing margins on sizing the thermal protection system (TPS). Results of this Monte Carlo approach are compared with traditional methods.

  3. A versatile system for biological and soil chemical tests on a planetary landing craft. II - Hardware development

    NASA Technical Reports Server (NTRS)

    Martin, J. P.; Kok, B.; Radmer, R.

    1976-01-01

    A system has been under development which is designed to seek remotely for clues to life in planetary soil samples. The basic approach is a set of experiments, all having a common sensor, a gas analysis mass spectrometer which monitors gas composition in the head spaces above sealed, temperature controlled soil samples. Versatility is obtained with up to three preloaded, sealed fluid injector capsules for each of eleven soil test cells. Tests results with an engineering model has demonstrated performance capability of subsystem components such as soil distribution, gas sampling valves, injector mechanisms, temperature control, and test cell seal.

  4. ERTS data user investigation to develop a multistage forest sampling inventory system

    NASA Technical Reports Server (NTRS)

    Langley, P. G.; Vanroessel, J. W. (Principal Investigator); Wert, S. L.

    1973-01-01

    The author has identified the following significant results. A system to provide precision annotation of predetermined forest inventory sampling units on the ERTS-1 MSS images was developed. In addition, an annotation system for high altitude U2 photographs was completed. MSS bulk image accuracy is good enough to allow the use of one square mile sampling units. IMANCO image analyzer interpretation work for small scale images demonstrated the need for much additional analyses. Continuing image interpretation work for the next reporting period is concentrated on manual image interpretation work as well as digital interpretation system development using the computer compatible tapes.

  5. High-field dynamic nuclear polarization in aqueous solutions.

    PubMed

    Prandolini, M J; Denysenkov, V P; Gafurov, M; Endeward, B; Prisner, T F

    2009-05-06

    Unexpected high DNP enhancements of more than 10 have been achieved in liquid water samples at room temperature and magnetic fields of 9.2 T (corresponding to 400 MHz (1)H NMR frequency and 260 GHz EPR frequency). The liquid samples were polarized in situ using a double-resonance structure, which allows simultaneous excitation of NMR and EPR transitions and achieves significant DNP enhancements at very low incident microwave power of only 45 mW. These results demonstrate the first important step toward the application of DNP to high-resolution NMR, increasing the sensitivity on biomolecules with small sample volumes and at physiologically low concentrations.

  6. A demonstration of NIOSH push-pull ventilation criteria.

    PubMed

    Klein, M K

    1987-03-01

    This paper summarizes the results of a study performed on an actual chrome plating tank in order to validate criteria for push-pull ventilation systems developed by Huebener and Hughes at NIOSH. Validation of the criteria was made by taking area industrial hygiene samples for hexavalent and total chrome at ten locations around the plating tank. The sampling was performed during actual production runs or while the tank was operating with a dummy load. The sampling data are summarized. The data show that the push-pull system, operating at Huebener's criteria, could control emissions to below the current standards and guidelines. Conclusions and recommendations are included.

  7. Screening experiments of ecstasy street samples using near infrared spectroscopy.

    PubMed

    Sondermann, N; Kovar, K A

    1999-12-20

    Twelve different sets of confiscated ecstasy samples were analysed applying both near infrared spectroscopy in reflectance mode (1100-2500 nm) and high-performance liquid chromatography (HPLC). The sets showed a large variance in composition. A calibration data set was generated based on the theory of factorial designs. It contained 221 N-methyl-3,4-methylenedioxyamphetamine (MDMA) samples, 167 N-ethyl-3,4-methylenedioxyamphetamine (MDE), 111 amphetamine and 106 samples without a controlled substance, which will be called placebo samples thereafter. From this data set, PLS-1 models were calculated and were successfully applied for validation of various external laboratory test sets. The transferability of these results to confiscated tablets is demonstrated here. It is shown that differentiation into placebo, amphetamine and ecstasy samples is possible. Analysis of intact tablets is practicable. However, more reliable results are obtained from pulverised samples. This is due to ill-defined production procedures. The use of mathematically pretreated spectra improves the prediction quality of all the PLS-1 models studied. It is possible to improve discrimination between MDE and MDMA with the help of a second model based on raw spectra. Alternative strategies are briefly discussed.

  8. Radial q-space sampling for DSI

    PubMed Central

    Baete, Steven H.; Yutzy, Stephen; Boada, Fernando, E.

    2015-01-01

    Purpose Diffusion Spectrum Imaging (DSI) has been shown to be an effective tool for non-invasively depicting the anatomical details of brain microstructure. Existing implementations of DSI sample the diffusion encoding space using a rectangular grid. Here we present a different implementation of DSI whereby a radially symmetric q-space sampling scheme for DSI (RDSI) is used to improve the angular resolution and accuracy of the reconstructed Orientation Distribution Functions (ODF). Methods Q-space is sampled by acquiring several q-space samples along a number of radial lines. Each of these radial lines in q-space is analytically connected to a value of the ODF at the same angular location by the Fourier slice theorem. Results Computer simulations and in vivo brain results demonstrate that RDSI correctly estimates the ODF when moderately high b-values (4000 s/mm2) and number of q-space samples (236) are used. Conclusion The nominal angular resolution of RDSI depends on the number of radial lines used in the sampling scheme, and only weakly on the maximum b-value. In addition, the radial analytical reconstruction reduces truncation artifacts which affect Cartesian reconstructions. Hence, a radial acquisition of q-space can be favorable for DSI. PMID:26363002

  9. Propionibacterium acnes Recovered from Atherosclerotic Human Carotid Arteries Undergoes Biofilm Dispersion and Releases Lipolytic and Proteolytic Enzymes in Response to Norepinephrine Challenge In Vitro.

    PubMed

    Lanter, Bernard B; Davies, David G

    2015-10-01

    In the present study, human atherosclerotic carotid arteries were examined following endarterectomy for the presence of the Gram-positive bacterium Propionibacterium acnes and its potential association with biofilm structures within the arterial wall. The P. acnes 16S rRNA gene was detectable in 4 of 15 carotid artery samples, and viable P. acnes was one among 10 different bacterial species recoverable in culture. Fluorescence in situ hybridization analysis of 5 additional atherosclerotic carotid arteries demonstrated biofilm bacteria within all samples, with P. acnes detectable in 4 samples. We also demonstrated that laboratory-grown cultures of P. acnes biofilms were susceptible to induction of a biofilm dispersion response when challenged with physiologically relevant levels of norepinephrine in the presence of iron-bound transferrin or with free iron. The production and release of lipolytic and proteolytic extracellular enzymes by P. acnes were shown to increase in iron-induced dispersed biofilms, and these dispersion-induced P. acnes VP1 biofilms showed increased expression of mRNAs for the triacylglycerol lipases PPA2105 and PPA1796 and the hyaluronate lyase PPA380 compared to that in untreated biofilms. These results demonstrate that P. acnes can infect the carotid arteries of humans with atherosclerosis as a component of multispecies biofilms and that dispersion is inducible for this organism, at least in vitro, with physiologically relevant levels of norepinephrine resulting in the production and release of degradative enzymes. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  10. Analytical results from ground-water sampling using a direct-push technique at the Dover National Test Site, Dover Air Force Base, Delaware, June-July 2001

    USGS Publications Warehouse

    Guertal, William R.; Stewart, Marie; Barbaro, Jeffrey R.; McHale, Timthoy J.

    2004-01-01

    A joint study by the Dover National Test Site and the U.S. Geological Survey was conducted from June 27 through July 18, 2001 to determine the spatial distribution of the gasoline oxygenate additive methyl tert-butyl ether and selected water-quality constituents in the surficial aquifer underlying the Dover National Test Site at Dover Air Force Base, Delaware. The study was conducted to support a planned enhanced bio-remediation demonstration and to assist the Dover National Test Site in identifying possible locations for future methyl tert-butyl ether remediation demonstrations. This report presents the analytical results from ground-water samples collected during the direct-push ground-water sampling study. A direct-push drill rig was used to quickly collect 115 ground-water samples over a large area at varying depths. The ground-water samples and associated quality-control samples were analyzed for volatile organic compounds and methyl tert-butyl ether by the Dover National Test Site analytical laboratory. Volatile organic compounds were above the method reporting limits in 59 of the 115 ground-water samples. The concentrations ranged from below detection limits to maximum values of 12.4 micrograms per liter of cis-1,2-dichloroethene, 1.14 micrograms per liter of trichloroethene, 2.65 micrograms per liter of tetrachloroethene, 1,070 micrograms per liter of methyl tert-butyl ether, 4.36 micrograms per liter of benzene, and 1.8 micrograms per liter of toluene. Vinyl chloride, ethylbenzene, p,m-xylene, and o-xylene were not detected in any of the samples collected during this investigation. Methyl tert-butyl ether was detected in 47 of the 115 ground-water samples. The highest methyl tert-butyl ether concentrations were found in the surficial aquifer from -4.6 to 6.4 feet mean sea level, however, methyl tert-butyl ether was detected as deep as -9.5 feet mean sea level. Increased methane concentrations and decreased dissolved oxygen concentrations were found in samples that contained methyl tert-butyl ether.

  11. Near-Native Protein Loop Sampling Using Nonparametric Density Estimation Accommodating Sparcity

    PubMed Central

    Day, Ryan; Lennox, Kristin P.; Sukhanov, Paul; Dahl, David B.; Vannucci, Marina; Tsai, Jerry

    2011-01-01

    Unlike the core structural elements of a protein like regular secondary structure, template based modeling (TBM) has difficulty with loop regions due to their variability in sequence and structure as well as the sparse sampling from a limited number of homologous templates. We present a novel, knowledge-based method for loop sampling that leverages homologous torsion angle information to estimate a continuous joint backbone dihedral angle density at each loop position. The φ,ψ distributions are estimated via a Dirichlet process mixture of hidden Markov models (DPM-HMM). Models are quickly generated based on samples from these distributions and were enriched using an end-to-end distance filter. The performance of the DPM-HMM method was evaluated against a diverse test set in a leave-one-out approach. Candidates as low as 0.45 Å RMSD and with a worst case of 3.66 Å were produced. For the canonical loops like the immunoglobulin complementarity-determining regions (mean RMSD <2.0 Å), the DPM-HMM method performs as well or better than the best templates, demonstrating that our automated method recaptures these canonical loops without inclusion of any IgG specific terms or manual intervention. In cases with poor or few good templates (mean RMSD >7.0 Å), this sampling method produces a population of loop structures to around 3.66 Å for loops up to 17 residues. In a direct test of sampling to the Loopy algorithm, our method demonstrates the ability to sample nearer native structures for both the canonical CDRH1 and non-canonical CDRH3 loops. Lastly, in the realistic test conditions of the CASP9 experiment, successful application of DPM-HMM for 90 loops from 45 TBM targets shows the general applicability of our sampling method in loop modeling problem. These results demonstrate that our DPM-HMM produces an advantage by consistently sampling near native loop structure. The software used in this analysis is available for download at http://www.stat.tamu.edu/~dahl/software/cortorgles/. PMID:22028638

  12. Characterizing quantum supremacy in near-term devices

    NASA Astrophysics Data System (ADS)

    Boixo, Sergio; Isakov, Sergei V.; Smelyanskiy, Vadim N.; Babbush, Ryan; Ding, Nan; Jiang, Zhang; Bremner, Michael J.; Martinis, John M.; Neven, Hartmut

    2018-06-01

    A critical question for quantum computing in the near future is whether quantum devices without error correction can perform a well-defined computational task beyond the capabilities of supercomputers. Such a demonstration of what is referred to as quantum supremacy requires a reliable evaluation of the resources required to solve tasks with classical approaches. Here, we propose the task of sampling from the output distribution of random quantum circuits as a demonstration of quantum supremacy. We extend previous results in computational complexity to argue that this sampling task must take exponential time in a classical computer. We introduce cross-entropy benchmarking to obtain the experimental fidelity of complex multiqubit dynamics. This can be estimated and extrapolated to give a success metric for a quantum supremacy demonstration. We study the computational cost of relevant classical algorithms and conclude that quantum supremacy can be achieved with circuits in a two-dimensional lattice of 7 × 7 qubits and around 40 clock cycles. This requires an error rate of around 0.5% for two-qubit gates (0.05% for one-qubit gates), and it would demonstrate the basic building blocks for a fault-tolerant quantum computer.

  13. Super resolution reconstruction of infrared images based on classified dictionary learning

    NASA Astrophysics Data System (ADS)

    Liu, Fei; Han, Pingli; Wang, Yi; Li, Xuan; Bai, Lu; Shao, Xiaopeng

    2018-05-01

    Infrared images always suffer from low-resolution problems resulting from limitations of imaging devices. An economical approach to combat this problem involves reconstructing high-resolution images by reasonable methods without updating devices. Inspired by compressed sensing theory, this study presents and demonstrates a Classified Dictionary Learning method to reconstruct high-resolution infrared images. It classifies features of the samples into several reasonable clusters and trained a dictionary pair for each cluster. The optimal pair of dictionaries is chosen for each image reconstruction and therefore, more satisfactory results is achieved without the increase in computational complexity and time cost. Experiments and results demonstrated that it is a viable method for infrared images reconstruction since it improves image resolution and recovers detailed information of targets.

  14. Switching characteristics in Cu:SiO2 by chemical soak methods for resistive random access memory (ReRAM)

    NASA Astrophysics Data System (ADS)

    Chin, Fun-Tat; Lin, Yu-Hsien; Yang, Wen-Luh; Liao, Chin-Hsuan; Lin, Li-Min; Hsiao, Yu-Ping; Chao, Tien-Sheng

    2015-01-01

    A limited copper (Cu)-source Cu:SiO2 switching layer composed of various Cu concentrations was fabricated using a chemical soaking (CS) technique. The switching layer was then studied for developing applications in resistive random access memory (ReRAM) devices. Observing the resistive switching mechanism exhibited by all the samples suggested that Cu conductive filaments formed and ruptured during the set/reset process. The experimental results indicated that the endurance property failure that occurred was related to the joule heating effect. Moreover, the endurance switching cycle increased as the Cu concentration decreased. In high-temperature tests, the samples demonstrated that the operating (set/reset) voltages decreased as the temperature increased, and an Arrhenius plot was used to calculate the activation energy of the set/reset process. In addition, the samples demonstrated stable data retention properties when baked at 85 °C, but the samples with low Cu concentrations exhibited short retention times in the low-resistance state (LRS) during 125 °C tests. Therefore, Cu concentration is a crucial factor in the trade-off between the endurance and retention properties; furthermore, the Cu concentration can be easily modulated using this CS technique.

  15. A European multicenter study on the analytical performance of the VERIS HBV assay.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Maria Angeles; Sauné, Karine; O Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    Hepatitis B viral load monitoring is an essential part of managing patients with chronic Hepatits B infection. Beckman Coulter has developed the VERIS HBV Assay for use on the fully automated Beckman Coulter DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the analytical performance of the VERIS HBV Assay at multiple European virology laboratories. Precision, analytical sensitivity, negative sample performance, linearity and performance with major HBV genotypes/subtypes for the VERIS HBV Assay was evaluated. Precision showed an SD of 0.15 log 10 IU/mL or less for each level tested. Analytical sensitivity determined by probit analysis was between 6.8-8.0 IU/mL. Clinical specificity on 90 unique patient samples was 100.0%. Performance with 754 negative samples demonstrated 100.0% not detected results, and a carryover study showed no cross contamination. Linearity using clinical samples was shown from 1.23-8.23 log 10 IU/mL and the assay detected and showed linearity with major HBV genotypes/subtypes. The VERIS HBV Assay demonstrated comparable analytical performance to other currently marketed assays for HBV DNA monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Exact sampling hardness of Ising spin models

    NASA Astrophysics Data System (ADS)

    Fefferman, B.; Foss-Feig, M.; Gorshkov, A. V.

    2017-09-01

    We study the complexity of classically sampling from the output distribution of an Ising spin model, which can be implemented naturally in a variety of atomic, molecular, and optical systems. In particular, we construct a specific example of an Ising Hamiltonian that, after time evolution starting from a trivial initial state, produces a particular output configuration with probability very nearly proportional to the square of the permanent of a matrix with arbitrary integer entries. In a similar spirit to boson sampling, the ability to sample classically from the probability distribution induced by time evolution under this Hamiltonian would imply unlikely complexity theoretic consequences, suggesting that the dynamics of such a spin model cannot be efficiently simulated with a classical computer. Physical Ising spin systems capable of achieving problem-size instances (i.e., qubit numbers) large enough so that classical sampling of the output distribution is classically difficult in practice may be achievable in the near future. Unlike boson sampling, our current results only imply hardness of exact classical sampling, leaving open the important question of whether a much stronger approximate-sampling hardness result holds in this context. The latter is most likely necessary to enable a convincing experimental demonstration of quantum supremacy. As referenced in a recent paper [A. Bouland, L. Mancinska, and X. Zhang, in Proceedings of the 31st Conference on Computational Complexity (CCC 2016), Leibniz International Proceedings in Informatics (Schloss Dagstuhl-Leibniz-Zentrum für Informatik, Dagstuhl, 2016)], our result completes the sampling hardness classification of two-qubit commuting Hamiltonians.

  17. Advisory Algorithm for Scheduling Open Sectors, Operating Positions, and Workstations

    NASA Technical Reports Server (NTRS)

    Bloem, Michael; Drew, Michael; Lai, Chok Fung; Bilimoria, Karl D.

    2012-01-01

    Air traffic controller supervisors configure available sector, operating position, and work-station resources to safely and efficiently control air traffic in a region of airspace. In this paper, an algorithm for assisting supervisors with this task is described and demonstrated on two sample problem instances. The algorithm produces configuration schedule advisories that minimize a cost. The cost is a weighted sum of two competing costs: one penalizing mismatches between configurations and predicted air traffic demand and another penalizing the effort associated with changing configurations. The problem considered by the algorithm is a shortest path problem that is solved with a dynamic programming value iteration algorithm. The cost function contains numerous parameters. Default values for most of these are suggested based on descriptions of air traffic control procedures and subject-matter expert feedback. The parameter determining the relative importance of the two competing costs is tuned by comparing historical configurations with corresponding algorithm advisories. Two sample problem instances for which appropriate configuration advisories are obvious were designed to illustrate characteristics of the algorithm. Results demonstrate how the algorithm suggests advisories that appropriately utilize changes in airspace configurations and changes in the number of operating positions allocated to each open sector. The results also demonstrate how the advisories suggest appropriate times for configuration changes.

  18. Positron spectroscopy studies of zeolites

    NASA Astrophysics Data System (ADS)

    Hung, Ku-Jung

    The lineshapes of two-dimensional angular correlation of electron-positron annihilation radiation (2D-ACAR) in alumina and several zeolites were measured as a function of internal surface areas. In all cases, the lineshape parameter S from 2D-ACAR spectra were found to vary proportionally with internal surface area. In order to investigate the Bronsted acidity in NaHY zeolite, the lineshape parameter evaluation from 2D-ACAR measurements for varied acidity in NaHY zeolites by ion-exchange and thermal desorption were presented. The result from this investigation has demonstrated that the Bronsted acidity in NaHY zeolite was found to vary linearly with the lineshape parameter of the angular correlation spectrum of the sample. The lineshapes of 2D-ACAR spectra were determined for different base adsorbed HY-zeolite samples under a temperature controlled heating system in order to investigate, in-situ, the acid strength and number of Bronsted acid sites in the sample. Results have shown that the lineshape parameter of the angular correlation spectrum of the sample increases with the strength of adsorbed base and decreases with the number of Bronsted acid sites in the sample. This indicated that the lineshape parameter is sensitive to all of the strengths and concentrations of Bronsted acid sites in the HY-zeolite samples. The result from this study has also demonstrated that the large size base, pyridine, would reduce the possibility of positronium formation in the sample by filling the cage to eliminate the internal surface areas where the positroniums are likely to form. However, the small size base, ammonia, did not show any effect on the internal surface areas. Owing to the fact that this technique monitors only the Bronsted acid sites that situate on the surface which relates to the catalytic activity, there is little ambiguity about the location of the source of information obtained. The findings presented in this dissertation point out the fact that such lineshape measurement of 2D-ACAR can well be an effective in-situ microprobe that could have important practical applications in internal surface characterization of zeolite catalysts in general.

  19. Femtosecond laser induced surface modification for prevention of bacterial adhesion on 45S5 bioactive glass

    NASA Astrophysics Data System (ADS)

    Shaikh, Shazia; Singh, Deepti; Subramanian, Mahesh; Kedia, Sunita; Singh, Anil Kumar; Singh, Kulwant; Gupta, Nidhi; Sinha, Sucharita

    2018-02-01

    Bacterial attachment and biofilm formation on implant surface has been a major concern in hospital and industrial environment. Prevention of bacterial infections of implant surface through surface treatment could be a potential solution and hence this has become a key area of research. In the present study, the antibacterial and biocompatible properties of femtosecond laser surface treated 45S5 bioactive glass (BG) have been investigated. Adhesion and sustainability of both gram positive S. aureus and gram negative P.aeruginosa and E. coli nosocomial bacteria on untreated and laser treated BG samples has been explored. An imprint method has been used to visualize the growth of bacteria on the sample surface. We observed complete bacterial rejection potentially reducing risk of biofilm formation on laser treated surface. This was correlated with surface roughness, wettability and change in surface chemical composition of the samples before and after laser treatment. Biocompatibility of the laser treated BG was demonstrated by studying the anchoring and growth of human cervix cell line INT407. Our results demonstrate that, laser surface modification of BG enables enhanced bacterial rejection without affecting its biocompatibility towards growth of human cells on it. These results open a significantly potential approach towards use of laser in successfully imparting desirable characteristics to BG based bio-implants and devices.

  20. Using Multistate Reweighting to Rapidly and Efficiently Explore Molecular Simulation Parameters Space for Nonbonded Interactions.

    PubMed

    Paliwal, Himanshu; Shirts, Michael R

    2013-11-12

    Multistate reweighting methods such as the multistate Bennett acceptance ratio (MBAR) can predict free energies and expectation values of thermodynamic observables at poorly sampled or unsampled thermodynamic states using simulations performed at only a few sampled states combined with single point energy reevaluations of these samples at the unsampled states. In this study, we demonstrate the power of this general reweighting formalism by exploring the effect of simulation parameters controlling Coulomb and Lennard-Jones cutoffs on free energy calculations and other observables. Using multistate reweighting, we can quickly identify, with very high sensitivity, the computationally least expensive nonbonded parameters required to obtain a specified accuracy in observables compared to the answer obtained using an expensive "gold standard" set of parameters. We specifically examine free energy estimates of three molecular transformations in a benchmark molecular set as well as the enthalpy of vaporization of TIP3P. The results demonstrates the power of this multistate reweighting approach for measuring changes in free energy differences or other estimators with respect to simulation or model parameters with very high precision and/or very low computational effort. The results also help to identify which simulation parameters affect free energy calculations and provide guidance to determine which simulation parameters are both appropriate and computationally efficient in general.

  1. Characterizing the localized surface plasmon resonance behaviors of Au nanorings and tracking their diffusion in bio-tissue with optical coherence tomography

    PubMed Central

    Lee, Cheng-Kuang; Tseng, Hung-Yu; Lee, Chia-Yun; Wu, Shou-Yen; Chi, Ting-Ta; Yang, Kai-Min; Chou, Han-Yi Elizabeth; Tsai, Meng-Tsan; Wang, Jyh-Yang; Kiang, Yean-Woei; Chiang, Chun-Pin; Yang, C. C.

    2010-01-01

    The characterization results of the localized surface plasmon resonance (LSPR) of Au nanorings (NRs) with optical coherence tomography (OCT) are first demonstrated. Then, the diffusion behaviors of Au NRs in mouse liver samples tracked with OCT are shown. For such research, aqueous solutions of Au NRs with two different localized surface plasmon resonance (LSPR) wavelengths are prepared and characterized. Their LSPR-induced extinction cross sections at 1310 nm are estimated with OCT scanning of solution droplets on coverslip to show reasonably consistent results with the data at individual LSPR wavelengths and at 1310 nm obtained from transmission measurements of Au NR solutions and numerical simulations. The resonant and non-resonant Au NRs are delivered into mouse liver samples for tracking Au NR diffusion in the samples through continuous OCT scanning for one hour. With resonant Au NRs, the average A-mode scan profiles of OCT scanning at different delay times clearly demonstrate the extension of strong backscattering depth with time. The calculation of speckle variance among successive OCT scanning images, which is related to the local transport speed of Au NRs, leads to the illustrations of downward propagation and spreading of major Au NR motion spot with time. PMID:21258530

  2. Effect of cryopreservation of peripheral blood mononuclear cells (PBMCs) on the variability of an antigen-specific memory B cell ELISpot.

    PubMed

    Trück, Johannes; Mitchell, Ruth; Thompson, Amber J; Morales-Aza, Begonia; Clutterbuck, Elizabeth A; Kelly, Dominic F; Finn, Adam; Pollard, Andrew J

    2014-01-01

    The ELISpot assay is used in vaccine studies for the quantification of antigen-specific memory B cells (B(MEM)), and can be performed using cryopreserved samples. The effects of cryopreservation on B(MEM) detection and the consistency of cultured ELISpot assays when performed by different operators or laboratories are unknown. In this study, blood was taken from healthy volunteers, and a cultured ELISpot assay was used to count B(MEM) specific for 2 routine vaccine antigens (diphtheria and tetanus toxoid). Results were assessed for intra- and inter-operator variation, and the effects of cryopreservation. Cryopreserved samples were shipped to a second laboratory in order to assess inter-laboratory variation. B(MEM) frequencies were very strongly correlated when comparing fresh and frozen samples processed by the same operator, and were also very strongly correlated when comparing 2 operators in the same laboratory. Results were slightly less consistent when samples were processed in different laboratories but correlation between the 2 measurements was still very strong. Although cell viability was reduced in some cryopreserved samples due to higher temperatures during transportation, B(MEM) could still be quantified. These results demonstrate the reproducibility of the ELISpot assay across operators and laboratories, and support the use of cryopreserved samples in future B(MEM) studies.

  3. Chemical contamination of soils in the New York City area following Hurricane Sandy.

    PubMed

    Mandigo, Amy C; DiScenza, Dana J; Keimowitz, Alison R; Fitzgerald, Neil

    2016-10-01

    This paper presents a unique data set of lead, arsenic, polychlorinated biphenyl (PCB), and polycyclic aromatic hydrocarbon (PAH) concentrations in soil samples collected from the metropolitan New York City area in the aftermath of Hurricane Sandy. Initial samples were collected by citizen scientists recruited via social media, a relatively unusual approach for a sample collection project. Participants in the affected areas collected 63 usable samples from basements, gardens, roads, and beaches. Results indicate high levels of arsenic, lead, PCBs, and PAHs in an area approximately 800 feet south of the United States Environmental Protection Agency (US EPA) Superfund site at Newtown Creek. A location adjacent to the Gowanus Canal, another Superfund site, was found to have high PCB concentrations. Areas of high PAH contamination tended to be near high traffic areas or next to sites of known contamination. While contamination as a direct result of Hurricane Sandy cannot be demonstrated conclusively, the presence of high levels of contamination close to known contamination sites, evidence for co-contamination, and decrease in number of samples containing measureable amounts of semi-volatile compounds from samples collected at similar locations 9 months after the storm suggest that contaminated particles may have migrated to residential areas as a result of flooding.

  4. Phenanthrene sorption with heterogeneous organic matter in a landfill aquifer material

    USGS Publications Warehouse

    Karapanagioti, H.K.; Sabatini, D.A.; Kleineidam, S.; Grathwohl, P.; Ligouis, B.

    1999-01-01

    Phenanthrene was used as a model chemical to study the sorption properties of Canadian River Alluvium aquifer material. Both equilibrium and kinetic sorption processes were evaluated through batch studies. The bulk sample was divided into subsamples with varying properties such as particle size, organic content, equilibration time, etc. in order to determine the effect of these properties on resulting sorption parameters. The data have been interpreted and the effect of experimental variables was quantified using the Freundlich isotherm model and a numerical solution of Fick's 2nd law in porous media. Microscopic organic matter characterization proved to be a valuable tool for explaining the results. Different organic matter properties and sorption mechanisms were observed for each soil subsample. Samples containing coal particles presented high Koc values. Samples with organic matter dominated by organic coatings on quartz grains presented low Koc values and contained a high percentage of fast sorption sites. The numerical solution of Fick's 2ndlaw requires the addition of two terms (fast and slow) in order to fit the kinetics of these heterogeneous samples properly. These results thus demonstrate the need for soil organic matter characterization in order to predict and explain the sorption properties of a soil sample containing heterogeneous organic matter and also the difficulty and complexity of modeling sorption in such samples.

  5. Monitoring of platinum surface contamination in seven Dutch hospital pharmacies using inductively coupled plasma mass spectrometry

    PubMed Central

    Huitema, A. D. R.; Bakker, E. N.; Douma, J. W.; Schimmel, K. J. M.; van Weringh, G.; de Wolf, P. J.; Schellens, J. H. M.; Beijnen, J. H.

    2007-01-01

    Objective: To develop, validate, and apply a method for the determination of platinum contamination, originating from cisplatinum, oxaliplatinum, and carboplatinum. Methods: Inductively coupled plasma mass spectrometry (ICP-MS) was used to determine platinum in wipe samples. The sampling procedure and the analytical conditions were optimised and the assay was validated. The method was applied to measure surface contamination in seven Dutch hospital pharmacies. Results: The developed method allowed reproducible quantification of 0.50 ng l−1 platinum (5 pg/wipe sample). Recoveries for stainless steel and linoleum surfaces ranged between 50.4 and 81.4% for the different platinum compounds tested. Platinum contamination was reported in 88% of the wipe samples. Although a substantial variation in surface contamination of the pharmacies was noticed, in most pharmacies, the laminar-airflow (LAF) hoods, the floor in front of the LAF hoods, door handles, and handles of service hatches showed positive results. This demonstrates that contamination is spread throughout the preparation rooms. Conclusion: We developed and validated an ultra sensitive and reliable ICP-MS method for the determination of platinum in surface samples. Surface contamination with platinum was observed in all hospital pharmacies sampled. The interpretation of these results is, however, complicated. PMID:17377802

  6. An integrated bioanalytical method development and validation approach: case studies.

    PubMed

    Xue, Y-J; Melo, Brian; Vallejo, Martha; Zhao, Yuwen; Tang, Lina; Chen, Yuan-Shek; Keller, Karin M

    2012-10-01

    We proposed an integrated bioanalytical method development and validation approach: (1) method screening based on analyte's physicochemical properties and metabolism information to determine the most appropriate extraction/analysis conditions; (2) preliminary stability evaluation using both quality control and incurred samples to establish sample collection, storage and processing conditions; (3) mock validation to examine method accuracy and precision and incurred sample reproducibility; and (4) method validation to confirm the results obtained during method development. This integrated approach was applied to the determination of compound I in rat plasma and compound II in rat and dog plasma. The effectiveness of the approach was demonstrated by the superior quality of three method validations: (1) a zero run failure rate; (2) >93% of quality control results within 10% of nominal values; and (3) 99% incurred sample within 9.2% of the original values. In addition, rat and dog plasma methods for compound II were successfully applied to analyze more than 900 plasma samples obtained from Investigational New Drug (IND) toxicology studies in rats and dogs with near perfect results: (1) a zero run failure rate; (2) excellent accuracy and precision for standards and quality controls; and (3) 98% incurred samples within 15% of the original values. Copyright © 2011 John Wiley & Sons, Ltd.

  7. The Predictive Validity of the Metropolitan Readiness Tests, 1976 Edition.

    ERIC Educational Resources Information Center

    Nagle, Richard J.

    1979-01-01

    A sample of 176 first-grade children was tested on the Metropolitan Readiness Tests, 1976 Edition (MRT), during the initial month of school and was retested eight months later on the Stanford Achievement Test. Results demonstrated substantial validity of the MRT for predicting first-grade achievement. (Author/CTM)

  8. Self-Concept and Social Interaction in a Deaf Population.

    ERIC Educational Resources Information Center

    Garrison, Wayne M; And Others

    Investigated were self concept levels of 109 deaf college students, and examined were social interaction behaviors among a subset of 27 Ss from the study sample. Results of the Tennessee Self Concept Scale indicated a response pattern demonstrating psychological distress or maladjustment, but reliability and comprehension analysis suggested that a…

  9. Adaptive Perfectionism, Maladaptive Perfectionism and Statistics Anxiety in Graduate Psychology Students

    ERIC Educational Resources Information Center

    Comerchero, Victoria; Fortugno, Dominick

    2013-01-01

    The current study examined if correlations between statistics anxiety and dimensions of perfectionism (adaptive and maladaptive) were present amongst a sample of psychology graduate students (N = 96). Results demonstrated that scores on the APS-R Discrepancy scale, corresponding to maladaptive perfectionism, correlated with higher levels of…

  10. Stratospheric Sampling and In Situ Atmospheric Chemical Element Analysis During Meteor Showers: A Resource Study

    NASA Technical Reports Server (NTRS)

    Noever, David A.

    2000-01-01

    Resources studies for asteroidal mining evaluation have depended historically on remote sensing analysis for chemical elements. During the November 1998 Leonids meteor shower, a stratospheric balloon and various low-density capture media were used to sample fragments from Comet Tempel-Tuttle debris during a peak Earth crossing. The analysis not only demonstrates how potential sampling strategies may improve the projections for metals or rare elements in astromining, but also benchmarks materials during low temperature (-60 F), high dessication environments as seen during atmospheric exposure. The results indicate high aluminum, magnesium and iron content for various sampled particles recovered, but generalization to the sporadic meteors expected from asteroidal sources will require future improvements in larger sampling volumes before a broad-use strategy for chemical analysis can be described. A repeat of the experimental procedure is planned for the November 1999 Leonids' shower, and various improvements for atmospheric sampling will be discussed.

  11. Has Adolescent Suicidality Decreased in the United States? Data From Two National Samples of Adolescents Interviewed in 1995 and 2005

    PubMed Central

    Wolitzky-Taylor, Kate B.; Ruggiero, Kenneth J.; McCart, Michael R.; Smith, Daniel W.; Hanson, Rochelle F.; Resnick, Heidi S.; de Arellano, Michael A.; Saunders, Benjamin E.; Kilpatrick, Dean G.

    2011-01-01

    We compared the prevalence and correlates of adolescent suicidal ideation and attempts in two nationally representative probability samples of adolescents interviewed in 1995 (National Survey of Adolescents; N =4,023) and 2005 (National Survey of Adolescents-Replication; N =3,614). Participants in both samples completed a telephone survey that assessed major depressive episode (MDE), post-traumatic stress disorder, suicidal ideation and attempts, violence exposure, and substance use. Results demonstrated that the lifetime prevalence of suicidal ideation among adolescents was lower in 2005 than 1995, whereas the prevalence of suicide attempts remained stable. MDE was the strongest predictor of suicidality in both samples. In addition, several demographic, substance use, and violence exposure variables were significantly associated with increased risk of suicidal ideation and attempts in both samples, with female gender, nonexperimental drug use, and direct violence exposure being consistent risk factors in both samples. PMID:20390799

  12. Determination of residual solvents in bulk pharmaceuticals by thermal desorption/gas chromatography/mass spectrometry.

    PubMed

    Urakami, K; Saito, Y; Fujiwara, Y; Watanabe, C; Umemoto, K; Godo, M; Hashimoto, K

    2000-12-01

    Thermal desorption (TD) techniques followed by capillary GC/MS were applied for the analysis of residual solvents in bulk pharmaceuticals. Solvents desorbed from samples by heating were cryofocused at the head of a capillary column prior to GC/MS analysis. This method requires a very small amount of sample and no sample pretreatment. Desorption temperature was set at the point about 20 degrees C higher than the melting point of each sample individually. The relative standard deviations of this method tested by performing six consecutive analyses of 8 different samples were 1.1 to 3.1%, and analytical results of residual solvents were in agreement with those obtained by direct injection of N,N-dimethylformamide solution of the samples into the GC. This novel TD/GC/MS method was demonstrated to be very useful for the identification and quantification of residual solvents in bulk pharmaceuticals.

  13. [Standardization of Blastocystis hominis diagnosis using different staining techniques].

    PubMed

    Eymael, Dayane; Schuh, Graziela Maria; Tavares, Rejane Giacomelli

    2010-01-01

    The present study was carried out from March to May 2008, with the aim of evaluating the effectiveness of different techniques for diagnosing Blastocystis hominis in a sample of the population attended at the Biomedicine Laboratory of Feevale University, Novo Hamburgo, Rio Grande do Sul. On hundred feces samples from children and adults were evaluated. After collection, the samples were subjected to the techniques of spontaneous sedimentation (HPJ), sedimentation in formalin-ether (Ritchie) and staining by means of Gram and May-Grünwald-Giemsa (MGG). The presence of Blastocystis hominis was observed in 40 samples, when staining techniques were used (MGG and Gram), while sedimentation techniques were less efficient (32 positive samples using the Ritchie technique and 20 positive samples using the HPJ technique). Our results demonstrate that HPJ was less efficient than the other methods, thus indicating the need to include laboratory techniques that enable parasite identification on a routine basis.

  14. Comparisons of discrete and integrative sampling accuracy in estimating pulsed aquatic exposures.

    PubMed

    Morrison, Shane A; Luttbeg, Barney; Belden, Jason B

    2016-11-01

    Most current-use pesticides have short half-lives in the water column and thus the most relevant exposure scenarios for many aquatic organisms are pulsed exposures. Quantifying exposure using discrete water samples may not be accurate as few studies are able to sample frequently enough to accurately determine time-weighted average (TWA) concentrations of short aquatic exposures. Integrative sampling methods that continuously sample freely dissolved contaminants over time intervals (such as integrative passive samplers) have been demonstrated to be a promising measurement technique. We conducted several modeling scenarios to test the assumption that integrative methods may require many less samples for accurate estimation of peak 96-h TWA concentrations. We compared the accuracies of discrete point samples and integrative samples while varying sampling frequencies and a range of contaminant water half-lives (t 50  = 0.5, 2, and 8 d). Differences the predictive accuracy of discrete point samples and integrative samples were greatest at low sampling frequencies. For example, when the half-life was 0.5 d, discrete point samples required 7 sampling events to ensure median values > 50% and no sampling events reporting highly inaccurate results (defined as < 10% of the true 96-h TWA). Across all water half-lives investigated, integrative sampling only required two samples to prevent highly inaccurate results and measurements resulting in median values > 50% of the true concentration. Regardless, the need for integrative sampling diminished as water half-life increased. For an 8-d water half-life, two discrete samples produced accurate estimates and median values greater than those obtained for two integrative samples. Overall, integrative methods are the more accurate method for monitoring contaminants with short water half-lives due to reduced frequency of extreme values, especially with uncertainties around the timing of pulsed events. However, the acceptability of discrete sampling methods for providing accurate concentration measurements increases with increasing aquatic half-lives. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Non destructive multi elemental analysis using prompt gamma neutron activation analysis techniques: Preliminary results for concrete sample

    NASA Astrophysics Data System (ADS)

    Dahing, Lahasen@Normanshah; Yahya, Redzuan; Yahya, Roslan; Hassan, Hearie

    2014-09-01

    In this study, principle of prompt gamma neutron activation analysis has been used as a technique to determine the elements in the sample. The system consists of collimated isotopic neutron source, Cf-252 with HPGe detector and Multichannel Analysis (MCA). Concrete with size of 10×10×10 cm3 and 15×15×15 cm3 were analysed as sample. When neutrons enter and interact with elements in the concrete, the neutron capture reaction will occur and produce characteristic prompt gamma ray of the elements. The preliminary result of this study demonstrate the major element in the concrete was determined such as Si, Mg, Ca, Al, Fe and H as well as others element, such as Cl by analysis the gamma ray lines respectively. The results obtained were compared with NAA and XRF techniques as a part of reference and validation. The potential and the capability of neutron induced prompt gamma as tool for multi elemental analysis qualitatively to identify the elements present in the concrete sample discussed.

  16. External validation of a Cox prognostic model: principles and methods

    PubMed Central

    2013-01-01

    Background A prognostic model should not enter clinical practice unless it has been demonstrated that it performs a useful role. External validation denotes evaluation of model performance in a sample independent of that used to develop the model. Unlike for logistic regression models, external validation of Cox models is sparsely treated in the literature. Successful validation of a model means achieving satisfactory discrimination and calibration (prediction accuracy) in the validation sample. Validating Cox models is not straightforward because event probabilities are estimated relative to an unspecified baseline function. Methods We describe statistical approaches to external validation of a published Cox model according to the level of published information, specifically (1) the prognostic index only, (2) the prognostic index together with Kaplan-Meier curves for risk groups, and (3) the first two plus the baseline survival curve (the estimated survival function at the mean prognostic index across the sample). The most challenging task, requiring level 3 information, is assessing calibration, for which we suggest a method of approximating the baseline survival function. Results We apply the methods to two comparable datasets in primary breast cancer, treating one as derivation and the other as validation sample. Results are presented for discrimination and calibration. We demonstrate plots of survival probabilities that can assist model evaluation. Conclusions Our validation methods are applicable to a wide range of prognostic studies and provide researchers with a toolkit for external validation of a published Cox model. PMID:23496923

  17. Variation in amino acid and lipid composition of latent fingerprints.

    PubMed

    Croxton, Ruth S; Baron, Mark G; Butler, David; Kent, Terry; Sears, Vaughn G

    2010-06-15

    The enhancement of latent fingerprints, both at the crime scene and in the laboratory using an array of chemical, physical and optical techniques, permits their use for identification. Despite the plethora of techniques available, there are occasions when latent fingerprints are not successfully enhanced. An understanding of latent fingerprint chemistry and behaviour will aid the improvement of current techniques and the development of novel ones. In this study the amino acid and fatty acid content of 'real' latent fingerprints collected on a non-porous surface was analysed by gas chromatography-mass spectrometry. Squalene was also quantified in addition. Hexadecanoic acid, octadecanoic acid and cis-9-octadecenoic acid were the most abundant fatty acids in all samples. There was, however, wide variation in the relative amounts of each fatty acid in each sample. It was clearly demonstrated that touching sebum-rich areas of the face immediately prior to fingerprint deposition resulted in a significant increase in the amount of fatty acids and squalene deposited in the resulting 'groomed' fingerprints. Serine was the most abundant amino acid identified followed by glycine, alanine and aspartic acid. The significant quantitative differences between the 'natural' and 'groomed' fingerprint samples seen for fatty acids were not observed in the case of the amino acids. This study demonstrates the variation in latent fingerprint composition between individuals and the impact of the sampling protocol on the quantitative analysis of fingerprints. (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  18. Note: A simple image processing based fiducial auto-alignment method for sample registration.

    PubMed

    Robertson, Wesley D; Porto, Lucas R; Ip, Candice J X; Nantel, Megan K T; Tellkamp, Friedjof; Lu, Yinfei; Miller, R J Dwayne

    2015-08-01

    A simple method for the location and auto-alignment of sample fiducials for sample registration using widely available MATLAB/LabVIEW software is demonstrated. The method is robust, easily implemented, and applicable to a wide variety of experiment types for improved reproducibility and increased setup speed. The software uses image processing to locate and measure the diameter and center point of circular fiducials for distance self-calibration and iterative alignment and can be used with most imaging systems. The method is demonstrated to be fast and reliable in locating and aligning sample fiducials, provided here by a nanofabricated array, with accuracy within the optical resolution of the imaging system. The software was further demonstrated to register, load, and sample the dynamically wetted array.

  19. An improved target velocity sampling algorithm for free gas elastic scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Romano, Paul K.; Walsh, Jonathan A.

    We present an improved algorithm for sampling the target velocity when simulating elastic scattering in a Monte Carlo neutron transport code that correctly accounts for the energy dependence of the scattering cross section. The algorithm samples the relative velocity directly, thereby avoiding a potentially inefficient rejection step based on the ratio of cross sections. Here, we have shown that this algorithm requires only one rejection step, whereas other methods of similar accuracy require two rejection steps. The method was verified against stochastic and deterministic reference results for upscattering percentages in 238U. Simulations of a light water reactor pin cell problemmore » demonstrate that using this algorithm results in a 3% or less penalty in performance when compared with an approximate method that is used in most production Monte Carlo codes« less

  20. An improved target velocity sampling algorithm for free gas elastic scattering

    DOE PAGES

    Romano, Paul K.; Walsh, Jonathan A.

    2018-02-03

    We present an improved algorithm for sampling the target velocity when simulating elastic scattering in a Monte Carlo neutron transport code that correctly accounts for the energy dependence of the scattering cross section. The algorithm samples the relative velocity directly, thereby avoiding a potentially inefficient rejection step based on the ratio of cross sections. Here, we have shown that this algorithm requires only one rejection step, whereas other methods of similar accuracy require two rejection steps. The method was verified against stochastic and deterministic reference results for upscattering percentages in 238U. Simulations of a light water reactor pin cell problemmore » demonstrate that using this algorithm results in a 3% or less penalty in performance when compared with an approximate method that is used in most production Monte Carlo codes« less

  1. Interferometric scanning optical microscope for surface characterization.

    PubMed

    Offside, M J; Somekh, M G

    1992-11-01

    A phase-sensitive scanning optical microscope is described that can measure surface height changes down to 0.1 nm. This is achieved by using two heterodyne Michelson interferometers in parallel. One interferometer probes the sample with a tightly focused beam, and the second has a collimated beam that illuminates a large area of the surface, providing a large area on sample reference. This is facilitated by using a specially constructed objective lens that permits the relative areas illuminated by the two probe beams to be varied both arbitrarily and independently, thus ensuring an accurate absolute phase measurement. We subtracted the phase outputs from each interferometer to provide the sample phase information, canceling the phase noise resulting from microphonics in the process. Results from a prototype version of the microscope are presented that demonstrate the advantages of the system over existing techniques.

  2. Assessing readability formula differences with written health information materials: application, results, and recommendations.

    PubMed

    Wang, Lih-Wern; Miller, Michael J; Schmitt, Michael R; Wen, Frances K

    2013-01-01

    Readability formulas are often used to guide the development and evaluation of literacy-sensitive written health information. However, readability formula results may vary considerably as a result of differences in software processing algorithms and how each formula is applied. These variations complicate interpretations of reading grade level estimates, particularly without a uniform guideline for applying and interpreting readability formulas. This research sought to (1) identify commonly used readability formulas reported in the health care literature, (2) demonstrate the use of the most commonly used readability formulas on written health information, (3) compare and contrast the differences when applying common readability formulas to identical selections of written health information, and (4) provide recommendations for choosing an appropriate readability formula for written health-related materials to optimize their use. A literature search was conducted to identify the most commonly used readability formulas in health care literature. Each of the identified formulas was subsequently applied to word samples from 15 unique examples of written health information about the topic of depression and its treatment. Readability estimates from common readability formulas were compared based on text sample size, selection, formatting, software type, and/or hand calculations. Recommendations for their use were provided. The Flesch-Kincaid formula was most commonly used (57.42%). Readability formulas demonstrated variability up to 5 reading grade levels on the same text. The Simple Measure of Gobbledygook (SMOG) readability formula performed most consistently. Depending on the text sample size, selection, formatting, software, and/or hand calculations, the individual readability formula estimated up to 6 reading grade levels of variability. The SMOG formula appears best suited for health care applications because of its consistency of results, higher level of expected comprehension, use of more recent validation criteria for determining reading grade level estimates, and simplicity of use. To improve interpretation of readability results, reporting reading grade level estimates from any formula should be accompanied with information about word sample size, location of word sampling in the text, formatting, and method of calculation. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Vacuum/compression valving (VCV) using parrafin-wax on a centrifugal microfluidic CD platform.

    PubMed

    Al-Faqheri, Wisam; Ibrahim, Fatimah; Thio, Tzer Hwai Gilbert; Moebius, Jacob; Joseph, Karunan; Arof, Hamzah; Madou, Marc

    2013-01-01

    This paper introduces novel vacuum/compression valves (VCVs) utilizing paraffin wax. A VCV is implemented by sealing the venting channel/hole with wax plugs (for normally-closed valve), or to be sealed by wax (for normally-open valve), and is activated by localized heating on the CD surface. We demonstrate that the VCV provides the advantages of avoiding unnecessary heating of the sample/reagents in the diagnostic process, allowing for vacuum sealing of the CD, and clear separation of the paraffin wax from the sample/reagents in the microfluidic process. As a proof of concept, the microfluidic processes of liquid flow switching and liquid metering is demonstrated with the VCV. Results show that the VCV lowers the required spinning frequency to perform the microfluidic processes with high accuracy and ease of control.

  4. Vacuum/Compression Valving (VCV) Using Parrafin-Wax on a Centrifugal Microfluidic CD Platform

    PubMed Central

    Al-Faqheri, Wisam; Ibrahim, Fatimah; Thio, Tzer Hwai Gilbert; Moebius, Jacob; Joseph, Karunan; Arof, Hamzah; Madou, Marc

    2013-01-01

    This paper introduces novel vacuum/compression valves (VCVs) utilizing paraffin wax. A VCV is implemented by sealing the venting channel/hole with wax plugs (for normally-closed valve), or to be sealed by wax (for normally-open valve), and is activated by localized heating on the CD surface. We demonstrate that the VCV provides the advantages of avoiding unnecessary heating of the sample/reagents in the diagnostic process, allowing for vacuum sealing of the CD, and clear separation of the paraffin wax from the sample/reagents in the microfluidic process. As a proof of concept, the microfluidic processes of liquid flow switching and liquid metering is demonstrated with the VCV. Results show that the VCV lowers the required spinning frequency to perform the microfluidic processes with high accuracy and ease of control. PMID:23505528

  5. Distinct Ecological Niche of Anal, Oral, and Cervical Mucosal Microbiomes in Adolescent Women.

    PubMed

    Smith, Benjamin C; Zolnik, Christine P; Usyk, Mykhaylo; Chen, Zigui; Kaiser, Katherine; Nucci-Sack, Anne; Peake, Ken; Diaz, Angela; Viswanathan, Shankar; Strickler, Howard D; Schlecht, Nicolas F; Burk, Robert D

    2016-09-01

    Human body sites represent ecological niches for microorganisms, each providing variations in microbial exposure, nutrient availability, microbial competition, and host immunological responses. In this study, we investigated the oral, anal, and cervical microbiomes from the same 20 sexually active adolescent females, using culture-independent, next-generation sequencing. DNA from each sample was amplified for the bacterial 16S rRNA gene and sequenced on an Illumina platform using paired-end reads. Across the three anatomical niches, we found significant differences in bacterial community composition and diversity. Overall anal samples were dominated with Prevotella and Bacteriodes , oral samples with Streptococcus and Prevotella , and cervical samples with Lactobacillus . The microbiomes of a few cervical samples clustered with anal samples in weighted principal coordinate analyses, due in part to a higher proportion of Prevotella in those samples. Additionally, cervical samples had the lowest alpha diversity. Our results demonstrate the occurrence of distinct microbial communities across body sites within the same individual.

  6. Uncertainties in the measurements of water-soluble organic nitrogen in the aerosol

    NASA Astrophysics Data System (ADS)

    Matsumoto, Kiyoshi; Yamato, Koki

    2016-11-01

    In order to evaluate the positive and negative artifacts in the measurements of the water-soluble organic nitrogen (WSON) in the aerosols by filter sampling, comparative experiments between the filter sampling and denuder-filter sampling were conducted during both the warm and cold seasons. The results suggest that the traditional filter sampling underestimates the concentrations of the particulate WSON due to its volatilization loss, but this effect on the ratio of the WSON to the water-soluble total nitrogen (WSTN) was small probably because inorganic nitrogen species were also lost during the filter sampling. Approximately 32.5% of the WSON in the PM2.5 was estimated to be lost during the filter sampling. The denuder-filter sampling also demonstrated the existence of the WSON in the gas phase with approximately quarter concentrations of the WSON in the PM2.5. On the other hand, the filter sampling would overestimate the gaseous WSON concentration due to the loss of the WSON from the aerosol collection filter.

  7. Steering Electromagnetic Fields in MRI: Investigating Radiofrequency Field Interactions with Endogenous and External Dielectric Materials for Improved Coil Performance at High Field

    NASA Astrophysics Data System (ADS)

    Vaidya, Manushka

    Although 1.5 and 3 Tesla (T) magnetic resonance (MR) systems remain the clinical standard, the number of 7 T MR systems has increased over the past decade because of the promise of higher signal-to-noise ratio (SNR), which can translate to images with higher resolution, improved image quality and faster acquisition times. However, there are a number of technical challenges that have prevented exploiting the full potential of ultra-high field (≥ 7 T) MR imaging (MRI), such as the inhomogeneous distribution of the radiofrequency (RF) electromagnetic field and specific energy absorption rate (SAR), which can compromise image quality and patient safety. To better understand the origin of these issues, we first investigated the dependence of the spatial distribution of the magnetic field associated with a surface RF coil on the operating frequency and electrical properties of the sample. Our results demonstrated that the asymmetries between the transmit (B1+) and receive (B 1-) circularly polarized components of the magnetic field, which are in part responsible for RF inhomogeneity, depend on the electric conductivity of the sample. On the other hand, when sample conductivity is low, a high relative permittivity can result in an inhomogeneous RF field distribution, due to significant constructive and destructive interference patterns between forward and reflected propagating magnetic field within the sample. We then investigated the use of high permittivity materials (HPMs) as a method to alter the field distribution and improve transmit and receive coil performance in MRI. We showed that HPM placed at a distance from an RF loop coil can passively shape the field within the sample. Our results showed improvement in transmit and receive sensitivity overlap, extension of coil field-of-view, and enhancement in transmit/receive efficiency. We demonstrated the utility of this concept by employing HPM to improve performance of an existing commercial head coil for the inferior regions of the brain, where the specific coil's imaging efficiency was inherently poor. Results showed a gain in SNR, while the maximum local and head SAR values remained below the prescribed limits. We showed that increasing coil performance with HPM could improve detection of functional MR activation during a motor-based task for whole brain fMRI. Finally, to gain an intuitive understanding of how HPM improves coil performance, we investigated how HPM separately affects signal and noise sensitivity to improve SNR. For this purpose, we employed a theoretical model based on dyadic Green's functions to compare the characteristics of current patterns, i.e. the optimal spatial distribution of coil conductors, that would either maximize SNR (ideal current patterns), maximize signal reception (signal-only optimal current patterns), or minimize sample noise (dark mode current patterns). Our results demonstrated that the presence of a lossless HPM changed the relative balance of signal-only optimal and dark mode current patterns. For a given relative permittivity, increasing the thickness of the HPM altered the magnitude of the currents required to optimize signal sensitivity at the voxel of interest as well as decreased the net electric field in the sample, which is associated, via reciprocity, to the noise received from the sample. Our results also suggested that signal-only current patterns could be used to identify HPM configurations that lead to high SNR gain for RF coil arrays. We anticipate that physical insights from this work could be utilized to build the next generation of high performing RF coils integrated with HPM.

  8. Uniform neural tissue models produced on synthetic hydrogels using standard culture techniques.

    PubMed

    Barry, Christopher; Schmitz, Matthew T; Propson, Nicholas E; Hou, Zhonggang; Zhang, Jue; Nguyen, Bao K; Bolin, Jennifer M; Jiang, Peng; McIntosh, Brian E; Probasco, Mitchell D; Swanson, Scott; Stewart, Ron; Thomson, James A; Schwartz, Michael P; Murphy, William L

    2017-11-01

    The aim of the present study was to test sample reproducibility for model neural tissues formed on synthetic hydrogels. Human embryonic stem (ES) cell-derived precursor cells were cultured on synthetic poly(ethylene glycol) (PEG) hydrogels to promote differentiation and self-organization into model neural tissue constructs. Neural progenitor, vascular, and microglial precursor cells were combined on PEG hydrogels to mimic developmental timing, which produced multicomponent neural constructs with 3D neuronal and glial organization, organized vascular networks, and microglia with ramified morphologies. Spearman's rank correlation analysis of global gene expression profiles and a comparison of coefficient of variation for expressed genes demonstrated that replicate neural constructs were highly uniform to at least day 21 for samples from independent experiments. We also demonstrate that model neural tissues formed on PEG hydrogels using a simplified neural differentiation protocol correlated more strongly to in vivo brain development than samples cultured on tissue culture polystyrene surfaces alone. These results provide a proof-of-concept demonstration that 3D cellular models that mimic aspects of human brain development can be produced from human pluripotent stem cells with high sample uniformity between experiments by using standard culture techniques, cryopreserved cell stocks, and a synthetic extracellular matrix. Impact statement Pluripotent stem (PS) cells have been characterized by an inherent ability to self-organize into 3D "organoids" resembling stomach, intestine, liver, kidney, and brain tissues, offering a potentially powerful tool for modeling human development and disease. However, organoid formation must be quantitatively reproducible for applications such as drug and toxicity screening. Here, we report a strategy to produce uniform neural tissue constructs with reproducible global gene expression profiles for replicate samples from multiple experiments.

  9. Field demonstration of DNAPL dehalogenation using emulsified zero-valent iron

    NASA Technical Reports Server (NTRS)

    Quinn, Jacqueline; Geiger, Cherie; Clausen, Chris; Brooks, Kathleen; Coon, Christina; O'Hara, Suzanne; Krug, Thomas; Major, David; Yoon, Woong-Sang; Gavaskar, Arun; hide

    2005-01-01

    This paper describes the results of the first field-scale demonstration conducted to evaluate the performance of nanoscale emulsified zero-valent iron (EZVI) injected into the saturated zone to enhance in situ dehalogenation of dense, nonaqueous phase liquids (DNAPLs) containing trichloroethene (TCE). EZVI is an innovative and emerging remediation technology. EZVI is a surfactant-stabilized, biodegradable emulsion that forms emulsion droplets consisting of an oil-liquid membrane surrounding zero-valent iron (ZVI) particles in water. EZVI was injected over a five day period into eight wells in a demonstration test area within a larger DNAPL source area at NASA's Launch Complex 34 (LC34) using a pressure pulse injection method. Soil and groundwater samples were collected before and after treatment and analyzed for volatile organic compounds (VOCs) to evaluate the changes in VOC mass, concentration and mass flux. Significant reductions in TCE soil concentrations (>80%) were observed at four of the six soil sampling locations within 90 days of EZVI injection. Somewhat lower reductions were observed at the other two soil sampling locations where visual observations suggest that most of the EZVI migrated up above the target treatment depth. Significant reductions in TCE groundwater concentrations (57 to 100%) were observed at all depths targeted with EZVI. Groundwater samples from the treatment area also showed significant increases in the concentrations of cis-1,2-dichloroethene (cDCE), vinyl chloride (VC) and ethene. The decrease in concentrations of TCE in soil and groundwater samples following treatment with EZVI is believed to be due to abiotic degradation associated with the ZVI as well as biodegradation enhanced by the presence of the oil and surfactant in the EZVI emulsion.

  10. Field Demonstration of DNAPL Dehalogenation Using Emulsified Zero-Valent Iron

    NASA Technical Reports Server (NTRS)

    Quinn, Jacqueline; Geiger, Cherie; Clausen, Chris; Brooks, Kathleen; Coon, Christina; O'Hara, Suzanne; Krug, Thomas; Major, David; Yoon, Sam; Gavaskar, Arun; hide

    2004-01-01

    This paper describes the results of the first field-scale demonstration conducted to evaluate the performance of nano-scale emulsified zero-valent iron (EZVI) injected into the saturated zone to enhance in situ dehalogenation of dense, non-aqueous phase liquids (DNAPLs) containing trichloroethene (TCE). EZVI is an innovative and emerging remediation technology. EZVI is a surfactant-stabilized, biodegradable emulsion that forms emulsion droplets consisting of an oil-liquid membrane surrounding zero-valent iron (ZVI) particles in water. EZVI was injected over a five day period into eight wells in a demonstration test area within a larger DNAPL source area at NASA's Launch Complex 34 (LC34) using a pressure pulse injection method. Soil and groundwater samples were collected before and after treatment and analyzed for volatile organic compounds (V005) to evaluate the changes in VOC mass, concentration and mass flux. Significant reductions in TCE soil concentrations (>80%) were observed at four of the six soil sampling locations within 90 days of EZVI injection. Somewhat lower reductions were observed at the other two soil sampling locations where visual observations suggest that most of the EZVI migrated up above the target treatment depth. Significant reductions in TCE groundwater concentrations (57 to 100%) were observed at all depths targeted with EZVI. Groundwater samples from the treatment area also showed significant increases in the concentrations of cis-1,2-dichloroethene (cDCE), vinyl chloride (VC) and ethene. The decrease in concentrations of TCE in soil and groundwater samples following treatment with EZVI is believed to be due to abiotic degradation associated with the ZVI as well as biodegradation enhanced by the presence of the oil and surfactant in the EZVI emulsion.

  11. Application of FTA technology for sampling, recovery and molecular characterization of viral pathogens and virus-derived transgenes from plant tissues

    PubMed Central

    Ndunguru, Joseph; Taylor, Nigel J; Yadav, Jitender; Aly, Haytham; Legg, James P; Aveling, Terry; Thompson, Graham; Fauquet, Claude M

    2005-01-01

    Background Plant viral diseases present major constraints to crop production. Effective sampling of the viruses infecting plants is required to facilitate their molecular study and is essential for the development of crop protection and improvement programs. Retaining integrity of viral pathogens within sampled plant tissues is often a limiting factor in this process, most especially when sample sizes are large and when operating in developing counties and regions remote from laboratory facilities. FTA is a paper-based system designed to fix and store nucleic acids directly from fresh tissues pressed into the treated paper. We report here the use of FTA as an effective technology for sampling and retrieval of DNA and RNA viruses from plant tissues and their subsequent molecular analysis. Results DNA and RNA viruses were successfully recovered from leaf tissues of maize, cassava, tomato and tobacco pressed into FTA® Classic Cards. Viral nucleic acids eluted from FTA cards were found to be suitable for diagnostic molecular analysis by PCR-based techniques and restriction analysis, and for cloning and nucleotide sequencing in a manner equivalent to that offered by tradition isolation methods. Efficacy of the technology was demonstrated both from sampled greenhouse-grown plants and from leaf presses taken from crop plants growing in farmer's fields in East Africa. In addition, FTA technology was shown to be suitable for recovery of viral-derived transgene sequences integrated into the plant genome. Conclusion Results demonstrate that FTA is a practical, economical and sensitive method for sampling, storage and retrieval of viral pathogens and plant genomic sequences, when working under controlled conditions and in the field. Application of this technology has the potential to significantly increase ability to bring modern analytical techniques to bear on the viral pathogens infecting crop plants. PMID:15904535

  12. Cryo-tomography Tilt-series Alignment with Consideration of the Beam-induced Sample Motion

    PubMed Central

    Fernandez, Jose-Jesus; Li, Sam; Bharat, Tanmay A. M.; Agard, David A.

    2018-01-01

    Recent evidence suggests that the beam-induced motion of the sample during tilt-series acquisition is a major resolution-limiting factor in electron cryo-tomography (cryoET). It causes suboptimal tilt-series alignment and thus deterioration of the reconstruction quality. Here we present a novel approach to tilt-series alignment and tomographic reconstruction that considers the beam-induced sample motion through the tilt-series. It extends the standard fiducial-based alignment approach in cryoET by introducing quadratic polynomials to model the sample motion. The model can be used during reconstruction to yield a motion-compensated tomogram. We evaluated our method on various datasets with different sample sizes. The results demonstrate that our method could be a useful tool to improve the quality of tomograms and the resolution in cryoET. PMID:29410148

  13. Monitoring of toxic elements present in sludge of industrial waste using CF-LIBS.

    PubMed

    Kumar, Rohit; Rai, Awadhesh K; Alamelu, Devanathan; Aggarwal, Suresh K

    2013-01-01

    Industrial waste is one of the main causes of environmental pollution. Laser-induced breakdown spectroscopy (LIBS) was applied to detect the toxic metals in the sludge of industrial waste water. Sludge on filter paper was obtained after filtering the collected waste water samples from different sections of a water treatment plant situated in an industrial area of Kanpur City. The LIBS spectra of the sludge samples were recorded in the spectral range of 200 to 500 nm by focusing the laser light on sludge. Calibration-free laser-induced breakdown spectroscopy (CF-LIBS) technique was used for the quantitative measurement of toxic elements such as Cr and Pb present in the sample. We also used the traditional calibration curve approach to quantify these elements. The results obtained from CF-LIBS are in good agreement with the results from the calibration curve approach. Thus, our results demonstrate that CF-LIBS is an appropriate technique for quantitative analysis where reference/standard samples are not available to make the calibration curve. The results of the present experiment are alarming to the people living nearby areas of industrial activities, as the concentrations of toxic elements are quite high compared to the admissible limits of these substances.

  14. Probabilistic data integration and computational complexity

    NASA Astrophysics Data System (ADS)

    Hansen, T. M.; Cordua, K. S.; Mosegaard, K.

    2016-12-01

    Inverse problems in Earth Sciences typically refer to the problem of inferring information about properties of the Earth from observations of geophysical data (the result of nature's solution to the `forward' problem). This problem can be formulated more generally as a problem of `integration of information'. A probabilistic formulation of data integration is in principle simple: If all information available (from e.g. geology, geophysics, remote sensing, chemistry…) can be quantified probabilistically, then different algorithms exist that allow solving the data integration problem either through an analytical description of the combined probability function, or sampling the probability function. In practice however, probabilistic based data integration may not be easy to apply successfully. This may be related to the use of sampling methods, which are known to be computationally costly. But, another source of computational complexity is related to how the individual types of information are quantified. In one case a data integration problem is demonstrated where the goal is to determine the existence of buried channels in Denmark, based on multiple sources of geo-information. Due to one type of information being too informative (and hence conflicting), this leads to a difficult sampling problems with unrealistic uncertainty. Resolving this conflict prior to data integration, leads to an easy data integration problem, with no biases. In another case it is demonstrated how imperfections in the description of the geophysical forward model (related to solving the wave-equation) can lead to a difficult data integration problem, with severe bias in the results. If the modeling error is accounted for, the data integration problems becomes relatively easy, with no apparent biases. Both examples demonstrate that biased information can have a dramatic effect on the computational efficiency solving a data integration problem and lead to biased results, and under-estimation of uncertainty. However, in both examples, one can also analyze the performance of the sampling methods used to solve the data integration problem to indicate the existence of biased information. This can be used actively to avoid biases in the available information and subsequently in the final uncertainty evaluation.

  15. Thermal Diffusivity of High-Density Polyethylene Samples of Different Crystallinity Evaluated by Indirect Transmission Photoacoustics

    NASA Astrophysics Data System (ADS)

    Nesic, M.; Popovic, M.; Rabasovic, M.; Milicevic, D.; Suljovrujic, E.; Markushev, D.; Stojanovic, Z.

    2018-02-01

    In this work, thermal diffusivity of crystalline high-density polyethylene samples of various thickness, and prepared using different procedures, was evaluated by transmission gas-microphone frequency photoacoustics. The samples' composition analysis and their degree of crystallinity were determined from the wide-angle X-ray diffraction, which confirmed that high-density polyethylene samples, obtained by slow and fast cooling, were equivalent in composition but with different degrees of crystallinity. Structural analysis, performed by differential scanning calorimetry, demonstrated that all of the used samples had different levels of crystallinity, depending not only on the preparing procedure, but also on sample thickness. Therefore, in order to evaluate the samples' thermal diffusivity, it was necessary to modify standard photoacoustic fitting procedures (based on the normalization of photoacoustic amplitude and phase characteristics on two thickness levels) for the interpretation of photoacoustic measurements. The calculated values of thermal diffusivity were in the range of the expected literature values. Besides that, the obtained results indicate the unexpected correlation between the values of thermal diffusivity and thermal conductivity with the degree of crystallinity of the investigated geometrically thin samples. The results indicate the necessity of additional investigation of energy transport in macromolecular systems, as well as the possible employment of the photoacoustic techniques in order to clarify its mechanism.

  16. Selective whole genome amplification for resequencing target microbial species from complex natural samples.

    PubMed

    Leichty, Aaron R; Brisson, Dustin

    2014-10-01

    Population genomic analyses have demonstrated power to address major questions in evolutionary and molecular microbiology. Collecting populations of genomes is hindered in many microbial species by the absence of a cost effective and practical method to collect ample quantities of sufficiently pure genomic DNA for next-generation sequencing. Here we present a simple method to amplify genomes of a target microbial species present in a complex, natural sample. The selective whole genome amplification (SWGA) technique amplifies target genomes using nucleotide sequence motifs that are common in the target microbe genome, but rare in the background genomes, to prime the highly processive phi29 polymerase. SWGA thus selectively amplifies the target genome from samples in which it originally represented a minor fraction of the total DNA. The post-SWGA samples are enriched in target genomic DNA, which are ideal for population resequencing. We demonstrate the efficacy of SWGA using both laboratory-prepared mixtures of cultured microbes as well as a natural host-microbe association. Targeted amplification of Borrelia burgdorferi mixed with Escherichia coli at genome ratios of 1:2000 resulted in >10(5)-fold amplification of the target genomes with <6.7-fold amplification of the background. SWGA-treated genomic extracts from Wolbachia pipientis-infected Drosophila melanogaster resulted in up to 70% of high-throughput resequencing reads mapping to the W. pipientis genome. By contrast, 2-9% of sequencing reads were derived from W. pipientis without prior amplification. The SWGA technique results in high sequencing coverage at a fraction of the sequencing effort, thus allowing population genomic studies at affordable costs. Copyright © 2014 by the Genetics Society of America.

  17. Multiple objective optimization in reliability demonstration test

    DOE PAGES

    Lu, Lu; Anderson-Cook, Christine Michaela; Li, Mingyang

    2016-10-01

    Reliability demonstration tests are usually performed in product design or validation processes to demonstrate whether a product meets specified requirements on reliability. For binomial demonstration tests, the zero-failure test has been most commonly used due to its simplicity and use of minimum sample size to achieve an acceptable consumer’s risk level. However, this test can often result in unacceptably high risk for producers as well as a low probability of passing the test even when the product has good reliability. This paper explicitly explores the interrelationship between multiple objectives that are commonly of interest when planning a demonstration test andmore » proposes structured decision-making procedures using a Pareto front approach for selecting an optimal test plan based on simultaneously balancing multiple criteria. Different strategies are suggested for scenarios with different user priorities and graphical tools are developed to help quantify the trade-offs between choices and to facilitate informed decision making. As a result, potential impacts of some subjective user inputs on the final decision are studied to offer insights and useful guidance for general applications.« less

  18. Classical boson sampling algorithms with superior performance to near-term experiments

    NASA Astrophysics Data System (ADS)

    Neville, Alex; Sparrow, Chris; Clifford, Raphaël; Johnston, Eric; Birchall, Patrick M.; Montanaro, Ashley; Laing, Anthony

    2017-12-01

    It is predicted that quantum computers will dramatically outperform their conventional counterparts. However, large-scale universal quantum computers are yet to be built. Boson sampling is a rudimentary quantum algorithm tailored to the platform of linear optics, which has sparked interest as a rapid way to demonstrate such quantum supremacy. Photon statistics are governed by intractable matrix functions, which suggests that sampling from the distribution obtained by injecting photons into a linear optical network could be solved more quickly by a photonic experiment than by a classical computer. The apparently low resource requirements for large boson sampling experiments have raised expectations of a near-term demonstration of quantum supremacy by boson sampling. Here we present classical boson sampling algorithms and theoretical analyses of prospects for scaling boson sampling experiments, showing that near-term quantum supremacy via boson sampling is unlikely. Our classical algorithm, based on Metropolised independence sampling, allowed the boson sampling problem to be solved for 30 photons with standard computing hardware. Compared to current experiments, a demonstration of quantum supremacy over a successful implementation of these classical methods on a supercomputer would require the number of photons and experimental components to increase by orders of magnitude, while tackling exponentially scaling photon loss.

  19. Effects of Sample Selection Bias on the Accuracy of Population Structure and Ancestry Inference

    PubMed Central

    Shringarpure, Suyash; Xing, Eric P.

    2014-01-01

    Population stratification is an important task in genetic analyses. It provides information about the ancestry of individuals and can be an important confounder in genome-wide association studies. Public genotyping projects have made a large number of datasets available for study. However, practical constraints dictate that of a geographical/ethnic population, only a small number of individuals are genotyped. The resulting data are a sample from the entire population. If the distribution of sample sizes is not representative of the populations being sampled, the accuracy of population stratification analyses of the data could be affected. We attempt to understand the effect of biased sampling on the accuracy of population structure analysis and individual ancestry recovery. We examined two commonly used methods for analyses of such datasets, ADMIXTURE and EIGENSOFT, and found that the accuracy of recovery of population structure is affected to a large extent by the sample used for analysis and how representative it is of the underlying populations. Using simulated data and real genotype data from cattle, we show that sample selection bias can affect the results of population structure analyses. We develop a mathematical framework for sample selection bias in models for population structure and also proposed a correction for sample selection bias using auxiliary information about the sample. We demonstrate that such a correction is effective in practice using simulated and real data. PMID:24637351

  20. The prevalence of Clostridium difficile in cattle and sheep carcasses and the antibiotic susceptibility of isolates.

    PubMed

    Hampikyan, Hamparsun; Bingol, Enver Baris; Muratoglu, Karlo; Akkaya, Esra; Cetin, Omer; Colak, Hilal

    2018-05-01

    Clostridium difficile is an anaerobic, spore forming, rod shaped bacterium frequently isolated from butchery animals in recent years. The aim of this study is to evaluate the presence of C. difficile (especially ribotype 027 and 078) in cattle and sheep carcasses and to investigate the antibiotic susceptibility of isolates. The bacterium was isolated in 83 out of 247 (33.6%) cattle and 78 out of 308 (25.3%) sheep carcass samples. 15/83 (18.1%) cattle and 6/78 (7.7%) sheep isolates were identified as ribotype 027, whereas the other hypervirulent isolate ribotype 078 could not be detected among the analysed samples. Almost all isolates were susceptible to amoxicillin-clavulanic acid (98.8%), vancomycin (96.9%) and tetracycline (97.5%), whereas resistant to cefotaxim (97.5%) and imipenem (87.0%). In conclusion, the results demonstrate the presence of toxigenic C. difficile isolates in cattle and sheep carcasses on the slaughter line. As a result, the results of this study demonstrate the presence of toxigenic C. difficile isolates in cattle and sheep carcasses on the slaughter line. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Assessment of MARMOT Grain Growth Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fromm, B.; Zhang, Y.; Schwen, D.

    2015-12-01

    This report assesses the MARMOT grain growth model by comparing modeling predictions with experimental results from thermal annealing. The purpose here is threefold: (1) to demonstrate the validation approach of using thermal annealing experiments with non-destructive characterization, (2) to test the reconstruction capability and computation efficiency in MOOSE, and (3) to validate the grain growth model and the associated parameters that are implemented in MARMOT for UO 2. To assure a rigorous comparison, the 2D and 3D initial experimental microstructures of UO 2 samples were characterized using non-destructive Synchrotron x-ray. The same samples were then annealed at 2273K for grainmore » growth, and their initial microstructures were used as initial conditions for simulated annealing at the same temperature using MARMOT. After annealing, the final experimental microstructures were characterized again to compare with the results from simulations. So far, comparison between modeling and experiments has been done for 2D microstructures, and 3D comparison is underway. The preliminary results demonstrated the usefulness of the non-destructive characterization method for MARMOT grain growth model validation. A detailed analysis of the 3D microstructures is in progress to fully validate the current model in MARMOT.« less

  2. High-resolution X-ray diffraction with no sample preparation

    PubMed Central

    Turner, S. M. R.; Degryse, P.; Shortland, A. J.

    2017-01-01

    It is shown that energy-dispersive X-ray diffraction (EDXRD) implemented in a back-reflection geometry is extremely insensitive to sample morphology and positioning even in a high-resolution configuration. This technique allows high-quality X-ray diffraction analysis of samples that have not been prepared and is therefore completely non-destructive. The experimental technique was implemented on beamline B18 at the Diamond Light Source synchrotron in Oxfordshire, UK. The majority of the experiments in this study were performed with pre-characterized geological materials in order to elucidate the characteristics of this novel technique and to develop the analysis methods. Results are presented that demonstrate phase identification, the derivation of precise unit-cell parameters and extraction of microstructural information on unprepared rock samples and other sample types. A particular highlight was the identification of a specific polytype of a muscovite in an unprepared mica schist sample, avoiding the time-consuming and difficult preparation steps normally required to make this type of identification. The technique was also demonstrated in application to a small number of fossil and archaeological samples. Back-reflection EDXRD implemented in a high-resolution configuration shows great potential in the crystallographic analysis of cultural heritage artefacts for the purposes of scientific research such as provenancing, as well as contributing to the formulation of conservation strategies. Possibilities for moving the technique from the synchrotron into museums are discussed. The avoidance of the need to extract samples from high-value and rare objects is a highly significant advantage, applicable also in other potential research areas such as palaeontology, and the study of meteorites and planetary materials brought to Earth by sample-return missions. PMID:28660862

  3. [Rapid determination of fatty acids in soybean oils by transmission reflection-near infrared spectroscopy].

    PubMed

    Song, Tao; Zhang, Feng-ping; Liu, Yao-min; Wu, Zong-wen; Suo, You-rui

    2012-08-01

    In the present research, a novel method was established for determination of five fatty acids in soybean oil by transmission reflection-near infrared spectroscopy. The optimum conditions of mathematics model of five components (C16:0, C18:0, C18:1, C18:2 and C18:3) were studied, including the sample set selection, chemical value analysis, the detection methods and condition. Chemical value was analyzed by gas chromatography. One hundred fifty eight samples were selected, 138 for modeling set, 10 for testing set and 10 for unknown sample set. All samples were placed in sample pools and scanned by transmission reflection-near infrared spectrum after sonicleaning for 10 minute. The 1100-2500 nm spectral region was analyzed. The acquisition interval was 2 nm. Modified partial least square method was chosen for calibration mode creating. Result demonstrated that the 1-VR of five fatty acids between the reference value of the modeling sample set and the near infrared spectrum predictive value were 0.8839, 0.5830, 0.9001, 0.9776 and 0.9596, respectively. And the SECV of five fatty acids between the reference value of the modeling sample set and the near infrared spectrum predictive value were 0.42, 0.29, 0.83, 0.46 and 0.21, respectively. The standard error of the calibration (SECV) of five fatty acids between the reference value of testing sample set and the near infrared spectrum predictive value were 0.891, 0.790, 0.900, 0.976 and 0.942, respectively. It was proved that the near infrared spectrum predictive value was linear with chemical value and the mathematical model established for fatty acids of soybean oil was feasible. For validation, 10 unknown samples were selected for analysis by near infrared spectrum. The result demonstrated that the relative standard deviation between predict value and chemical value was less than 5.50%. That was to say that transmission reflection-near infrared spectroscopy had a good veracity in analysis of fatty acids of soybean oil.

  4. Chemical migration during soil water retention curve evaluation.

    PubMed

    Pires, Luiz F; Villanueva, Felipe C A; Dias, Nivea M P; Bacchi, Osny O Santos; Reichardt, Klaus

    2011-09-01

    Wetting and drying (W-D) cycles can induce important elemental migrations in soils. The main purpose of this work was to study the possible existence of soil chemical elemental migrations in samples submitted to repeated W-D cycles during evaluations of soil water retention curve (SWRC). The experimental measurements were carried out by Atomic Absorption Spectrometry (AAS) for Ca(2+), Mg(2+) and K(+) on samples of three different Brazilian tropical soils (Geric Ferralsol, Eutric Nitosol and Rhodic Ferralsol). Results demonstrate an increase in the electrical conductivity of the water extracted from the samples and significant losses of Ca(2+), Mg(2+) and K(+) during the applications of up to nine W-D cycles. It was also observed differences in SWRC for all soils when samples submitted to the application of several W-D cycles were compared with samples not submitted to it. These differences occurred at the region of both structural and textural pores. A possible explanation for these results could be the soil chemical migration during the sequences of W-D cycles, which can affect the soil structure development.

  5. ColiSense, today's sample today: A rapid on-site detection of β-D-Glucuronidase activity in surface water as a surrogate for E. coli.

    PubMed

    Heery, Brendan; Briciu-Burghina, Ciprian; Zhang, Dian; Duffy, Gillian; Brabazon, Dermot; O'Connor, Noel; Regan, Fiona

    2016-01-01

    A sensitive field-portable fluorimeter with incubating capability and triplicate sample chambers was designed and built. The system was optimised for the on-site analysis of E. coli in recreational waters using fluorescent based enzyme assays. The target analyte was β-D-Glucuronidase (GUS) which hydrolyses a synthetic substrate 6-Chloro-4-Methyl-Umbelliferyl-β-D-Glucuronide (6-CMUG) to release the fluorescent molecule 6-Chloro-4-Methyl-Umbelliferyl (6-CMU). The system was calibrated with 6-CMU standards. A LOD of 5 nM and a resolution of less than 1 nM was determined while enzyme kinetic tests showed detection of activities below 1 pmol min(-1) mL(-1) of sample. A field portable sample preparation, enzyme extraction protocol and continuous assay were applied with the system to analyse freshwater and marine samples. Results from a one day field trial are shown which demonstrated the ability of the system to deliver results on-site within a 75 min period. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Measurement of urinary calcium using AT89C51RD2 microcontroller.

    PubMed

    Neelamegam, P; Jamaludeen, A; Rajendran, A; Raghunathan, R

    2009-04-01

    A simple and inexpensive absorption technique for determination of calcium ion in urine samples is developed, comprising a light emitting diode (650 nm) as the light source and photodiode as the detector with AT89C51RD2 microcontroller. The design of the system and details of interface, calibration, and procedure of operation are explained in this paper. Software is developed to monitor sample processing and to display the results in liquid crystal display screen. With 15 microl sample volume, a linear output is obtained in the range of 2.5-7.5 mM calcium with a detection limit of 0.06 mM. Interferences from other cations such as monovalent ion and divalent ion are investigated in the expected range, which are normally present in clinical samples, and absorption changes over the pH range of 3-12 are also determined. This system has been demonstrated successfully for the successive assay of calcium in urine samples, with the results comparing well to those achieved and in good agreement with values obtained with the current clinical spectrophotometric method at 95% of confidence level.

  7. Perceived risk as a moderator of the effectiveness of framed HIV-test promotion messages among women: a randomized controlled trial.

    PubMed

    Hull, Shawnika J

    2012-01-01

    Researchers argue that gain-framed messages should be more effective for prevention behaviors, while loss frames should be more effective for detection behaviors (Rothman & Salovey, 1997). Evidence for this taxonomy has been mixed. This study examines whether the effects of gain- and loss-framed messages on HIV-testing intentions is moderated by perceived risk of a positive result. This experiment was conducted online and utilized a single factor (frame: gain/loss) between subjects design, with a separate HIV-test promotion control and a no message control to examine whether perceived risk of a positive test result moderates the effects of framed messages on intentions to seek an HIV test in the next 3 months. The sample (N = 1052; M age = 22, SD = 2.22), recruited through Survey Sampling International, included 51% Black women (49% White women). HIV-test promotion messages were more effective than no message, but there were no other main effects for condition. Results also demonstrated a significant interaction between message frame and perceived risk, which is mediated through elaborative processing of the message. The interaction demonstrated an advantage for the loss-framed message among women with some perceived risk and an advantage for the gain-framed message among women with low perceived risk. Results imply that the prevention/detection function of the behavior may be an inadequate distinction in the consideration of the effectiveness of framed messages promoting HIV testing. Rather, this study demonstrates that risk perceptions are an important moderator of framing effects.

  8. An information-theoretic approach to the modeling and analysis of whole-genome bisulfite sequencing data.

    PubMed

    Jenkinson, Garrett; Abante, Jordi; Feinberg, Andrew P; Goutsias, John

    2018-03-07

    DNA methylation is a stable form of epigenetic memory used by cells to control gene expression. Whole genome bisulfite sequencing (WGBS) has emerged as a gold-standard experimental technique for studying DNA methylation by producing high resolution genome-wide methylation profiles. Statistical modeling and analysis is employed to computationally extract and quantify information from these profiles in an effort to identify regions of the genome that demonstrate crucial or aberrant epigenetic behavior. However, the performance of most currently available methods for methylation analysis is hampered by their inability to directly account for statistical dependencies between neighboring methylation sites, thus ignoring significant information available in WGBS reads. We present a powerful information-theoretic approach for genome-wide modeling and analysis of WGBS data based on the 1D Ising model of statistical physics. This approach takes into account correlations in methylation by utilizing a joint probability model that encapsulates all information available in WGBS methylation reads and produces accurate results even when applied on single WGBS samples with low coverage. Using the Shannon entropy, our approach provides a rigorous quantification of methylation stochasticity in individual WGBS samples genome-wide. Furthermore, it utilizes the Jensen-Shannon distance to evaluate differences in methylation distributions between a test and a reference sample. Differential performance assessment using simulated and real human lung normal/cancer data demonstrate a clear superiority of our approach over DSS, a recently proposed method for WGBS data analysis. Critically, these results demonstrate that marginal methods become statistically invalid when correlations are present in the data. This contribution demonstrates clear benefits and the necessity of modeling joint probability distributions of methylation using the 1D Ising model of statistical physics and of quantifying methylation stochasticity using concepts from information theory. By employing this methodology, substantial improvement of DNA methylation analysis can be achieved by effectively taking into account the massive amount of statistical information available in WGBS data, which is largely ignored by existing methods.

  9. Rapid characterization of transgenic and non-transgenic soybean oils by chemometric methods using NIR spectroscopy

    NASA Astrophysics Data System (ADS)

    Luna, Aderval S.; da Silva, Arnaldo P.; Pinho, Jéssica S. A.; Ferré, Joan; Boqué, Ricard

    Near infrared (NIR) spectroscopy and multivariate classification were applied to discriminate soybean oil samples into non-transgenic and transgenic. Principal Component Analysis (PCA) was applied to extract relevant features from the spectral data and to remove the anomalous samples. The best results were obtained when with Support Vectors Machine-Discriminant Analysis (SVM-DA) and Partial Least Squares-Discriminant Analysis (PLS-DA) after mean centering plus multiplicative scatter correction. For SVM-DA the percentage of successful classification was 100% for the training group and 100% and 90% in validation group for non transgenic and transgenic soybean oil samples respectively. For PLS-DA the percentage of successful classification was 95% and 100% in training group for non transgenic and transgenic soybean oil samples respectively and 100% and 80% in validation group for non transgenic and transgenic respectively. The results demonstrate that NIR spectroscopy can provide a rapid, nondestructive and reliable method to distinguish non-transgenic and transgenic soybean oils.

  10. Contaminant concentration in environmental samples using LIBS and CF-LIBS

    NASA Astrophysics Data System (ADS)

    Pandhija, S.; Rai, N. K.; Rai, A. K.; Thakur, S. N.

    2010-01-01

    The present paper deals with the detection and quantification of toxic heavy metals like Cd, Co, Pb, Zn, Cr, etc. in environmental samples by using the technique of laser-induced breakdown spectroscopy (LIBS) and calibration-free LIBS (CF-LIBS). A MATLABTM program has been developed based on the CF-LIBS algorithm given by earlier workers and concentrations of pollutants present in industrial area soil have been determined. LIBS spectra of a number of certified reference soil samples with varying concentrations of toxic elements (Cd, Zn) have been recorded to obtain calibration curves. The concentrations of Cd and Zn in soil samples from the Jajmau area, Kanpur (India) have been determined by using these calibration curves and also by the CF-LIBS approach. Our results clearly demonstrate that the combination of LIBS and CF-LIBS is very useful for the study of pollutants in the environment. Some of the results have also been found to be in good agreement with those of ICP-OES.

  11. Separating the influence of electric charges in magnetic force microscopy images of inhomogeneous metal samples

    NASA Astrophysics Data System (ADS)

    Arenas, Mónica P.; Lanzoni, Evandro M.; Pacheco, Clara J.; Costa, Carlos A. R.; Eckstein, Carlos B.; de Almeida, Luiz H.; Rebello, João M. A.; Deneke, Christoph F.; Pereira, Gabriela R.

    2018-01-01

    In this study, we investigate artifacts arising from electric charges present in magnetic force microscopy images. Therefore, we use two austenitic steel samples with different microstructural conditions. Furthermore, we examine the influence of the surface preparation, like etching, in magnetic force images. Using Kelvin probe force microscopy we can quantify the charges present on the surface. Our results show that electrical charges give rise to a signature in the magnetic force microscopy, which is indistinguishable from a magnetic signal. Our results on two differently aged steel samples demonstrate that the magnetic force microscopy images need to be interpreted with care and must be corrected due to the influence of electrical charges present. We discuss three approaches, how to identify these artifacts - parallel acquisition of magnetic force and electric force images on the same position, sample surface preparation to decrease the presence of charges and inversion of the magnetic polarization in two succeeding measurement.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Di, Zichao; Chen, Si; Hong, Young Pyo

    X-ray fluorescence tomography is based on the detection of fluorescence x-ray photons produced following x-ray absorption while a specimen is rotated; it provides information on the 3D distribution of selected elements within a sample. One limitation in the quality of sample recovery is the separation of elemental signals due to the finite energy resolution of the detector. Another limitation is the effect of self-absorption, which can lead to inaccurate results with dense samples. To recover a higher quality elemental map, we combine x-ray fluorescence detection with a second data modality: conventional x-ray transmission tomography using absorption. By using these combinedmore » signals in a nonlinear optimization-based approach, we demonstrate the benefit of our algorithm on real experimental data and obtain an improved quantitative reconstruction of the spatial distribution of dominant elements in the sample. Furthermore, compared with single-modality inversion based on x-ray fluorescence alone, this joint inversion approach reduces ill-posedness and should result in improved elemental quantification and better correction of self-absorption.« less

  13. A Generalized Sampling and Preconditioning Scheme for Sparse Approximation of Polynomial Chaos Expansions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jakeman, John D.; Narayan, Akil; Zhou, Tao

    We propose an algorithm for recovering sparse orthogonal polynomial expansions via collocation. A standard sampling approach for recovering sparse polynomials uses Monte Carlo sampling, from the density of orthogonality, which results in poor function recovery when the polynomial degree is high. Our proposed approach aims to mitigate this limitation by sampling with respect to the weighted equilibrium measure of the parametric domain and subsequently solves a preconditionedmore » $$\\ell^1$$-minimization problem, where the weights of the diagonal preconditioning matrix are given by evaluations of the Christoffel function. Our algorithm can be applied to a wide class of orthogonal polynomial families on bounded and unbounded domains, including all classical families. We present theoretical analysis to motivate the algorithm and numerical results that show our method is superior to standard Monte Carlo methods in many situations of interest. In conclusion, numerical examples are also provided to demonstrate that our proposed algorithm leads to comparable or improved accuracy even when compared with Legendre- and Hermite-specific algorithms.« less

  14. A Generalized Sampling and Preconditioning Scheme for Sparse Approximation of Polynomial Chaos Expansions

    DOE PAGES

    Jakeman, John D.; Narayan, Akil; Zhou, Tao

    2017-06-22

    We propose an algorithm for recovering sparse orthogonal polynomial expansions via collocation. A standard sampling approach for recovering sparse polynomials uses Monte Carlo sampling, from the density of orthogonality, which results in poor function recovery when the polynomial degree is high. Our proposed approach aims to mitigate this limitation by sampling with respect to the weighted equilibrium measure of the parametric domain and subsequently solves a preconditionedmore » $$\\ell^1$$-minimization problem, where the weights of the diagonal preconditioning matrix are given by evaluations of the Christoffel function. Our algorithm can be applied to a wide class of orthogonal polynomial families on bounded and unbounded domains, including all classical families. We present theoretical analysis to motivate the algorithm and numerical results that show our method is superior to standard Monte Carlo methods in many situations of interest. In conclusion, numerical examples are also provided to demonstrate that our proposed algorithm leads to comparable or improved accuracy even when compared with Legendre- and Hermite-specific algorithms.« less

  15. Pathological video-game use among youth ages 8 to 18: a national study.

    PubMed

    Gentile, Douglas

    2009-05-01

    Researchers have studied whether some youth are "addicted" to video games, but previous studies have been based on regional convenience samples. Using a national sample, this study gathered information about video-gaming habits and parental involvement in gaming, to determine the percentage of youth who meet clinical-style criteria for pathological gaming. A Harris poll surveyed a randomly selected sample of 1,178 American youth ages 8 to 18. About 8% of video-game players in this sample exhibited pathological patterns of play. Several indicators documented convergent and divergent validity of the results: Pathological gamers spent twice as much time playing as nonpathological gamers and received poorer grades in school; pathological gaming also showed comorbidity with attention problems. Pathological status significantly predicted poorer school performance even after controlling for sex, age, and weekly amount of video-game play. These results confirm that pathological gaming can be measured reliably, that the construct demonstrates validity, and that it is not simply isomorphic with a high amount of play.

  16. Joint reconstruction of x-ray fluorescence and transmission tomography

    PubMed Central

    Di, Zichao Wendy; Chen, Si; Hong, Young Pyo; Jacobsen, Chris; Leyffer, Sven; Wild, Stefan M.

    2017-01-01

    X-ray fluorescence tomography is based on the detection of fluorescence x-ray photons produced following x-ray absorption while a specimen is rotated; it provides information on the 3D distribution of selected elements within a sample. One limitation in the quality of sample recovery is the separation of elemental signals due to the finite energy resolution of the detector. Another limitation is the effect of self-absorption, which can lead to inaccurate results with dense samples. To recover a higher quality elemental map, we combine x-ray fluorescence detection with a second data modality: conventional x-ray transmission tomography using absorption. By using these combined signals in a nonlinear optimization-based approach, we demonstrate the benefit of our algorithm on real experimental data and obtain an improved quantitative reconstruction of the spatial distribution of dominant elements in the sample. Compared with single-modality inversion based on x-ray fluorescence alone, this joint inversion approach reduces ill-posedness and should result in improved elemental quantification and better correction of self-absorption. PMID:28788848

  17. A novel magnet focusing plate for matrix-assisted laser desorption/ionization analysis of magnetic bead-bound analytes.

    PubMed

    Gode, David; Volmer, Dietrich A

    2013-05-15

    Magnetic beads are often used for serum profiling of peptide and protein biomarkers. In these assays, the bead-bound analytes are eluted from the beads prior to mass spectrometric analysis. This study describes a novel matrix-assisted laser desorption/ionization (MALDI) technique for direct application and focusing of magnetic beads to MALDI plates by means of dedicated micro-magnets as sample spots. Custom-made MALDI plates with magnetic focusing spots were made using small nickel-coated neodymium micro-magnets integrated into a stainless steel plate in a 16 × 24 (384) pattern. For demonstrating the proof-of-concept, commercial C-18 magnetic beads were used for the extraction of a test compound (reserpine) from aqueous solution. Experiments were conducted to study focusing abilities, the required laser energies, the influence of a matrix compound, dispensing techniques, solvent choice and the amount of magnetic beads. Dispensing the magnetic beads onto the micro-magnet sample spots resulted in immediate and strong binding to the magnetic surface. Light microscope images illustrated the homogeneous distribution of beads across the surfaces of the magnets, when the entire sample volume containing the beads was pipetted onto the surface. Subsequent MALDI analysis of the bead-bound analyte demonstrated excellent and reproducible ionization yields. The surface-assisted laser desorption/ionization (SALDI) properties of the strongly light-absorbing γ-Fe2O3-based beads resulted in similar ionization efficiencies to those obtained from experiments with an additional MALDI matrix compound. This feasibility study successfully demonstrated the magnetic focusing abilities for magnetic bead-bound analytes on a novel MALDI plate containing small micro-magnets as sample spots. One of the key advantages of this integrated approach is that no elution steps from magnetic beads were required during analyses compared with conventional bead experiments. Copyright © 2013 John Wiley & Sons, Ltd.

  18. Distribution of potentially bioavailable natural organic carbon in aquifer sediments at a chloroethene-contaminated site

    USGS Publications Warehouse

    Thomas, L.K.; Widdowson, M.A.; Chapelle, F.H.; Novak, J.T.; Boncal, J.E.; Lebrón, C. A.

    2012-01-01

    The distribution of natural organic carbon was investigated at a chloroethene-contaminated site where complete reductive dechlorination of tetrachloroethene (PCE) to vinyl chloride and ethene was observed. In this study, operationally defined potentially bioavailable organic carbon (PBOC) was measured in surficial aquifer sediment samples collected at varying depths and locations in the vicinity of a dense nonaqueous phase liquid (DNAPL) source and aqueous phase plume. The relationship between chloroethene concentrations and PBOC levels was examined by comparing differences in extractable organic carbon in aquifer sediments with minimal chloroethene exposure relative to samples collected in the source zone. Using performance-monitoring data, direct correlations with PBOC were also developed with chloroethene concentrations in groundwater. Results show a logarithm-normal distribution for PBOC in aquifer sediments with a mean concentration of 187  mg/kg. PBOC levels in sediments obtained from the underlying confining unit were generally greater when compared to sediments collected in the sandy surficial aquifer. Results demonstrated a statistically significant inverse correlation (p=0.007) between PBOC levels in aquifer sediments and chloroethene concentrations for selected monitoring wells in which chloroethene exposure was the highest. Results from laboratory exposure assays also demonstrated that sediment samples exhibited a reduction in PBOC levels of 35% and 73%, respectively, after a 72-h exposure period to PCE (20,000  μg/L). These results support the notion that PBOC depletion in sediments may be expected in chloroethene-contaminated aquifers, which has potential implications for the long-term sustainability of monitored natural attenuation.

  19. Non-destructive identification of unknown minor phases in polycrystalline bulk alloys using three-dimensional X-ray diffraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Yiming, E-mail: yangyiming1988@outlook.com

    Minor phases make considerable contributions to the mechanical and physical properties of metals and alloys. Unfortunately, it is difficult to identify unknown minor phases in a bulk polycrystalline material using conventional metallographic methods. Here, a non-destructive method based on three-dimensional X-ray diffraction (3DXRD) is developed to solve this problem. Simulation results demonstrate that this method is simultaneously able to identify minor phase grains and reveal their positions, orientations and sizes within bulk alloys. According to systematic simulations, the 3DXRD method is practicable for an extensive sample set, including polycrystalline alloys with hexagonal, orthorhombic and cubic minor phases. Experiments were alsomore » conducted to confirm the simulation results. The results for a bulk sample of aluminum alloy AA6061 show that the crystal grains of an unexpected γ-Fe (austenite) phase can be identified, three-dimensionally and nondestructively. Therefore, we conclude that the 3DXRD method is a powerful tool for the identification of unknown minor phases in bulk alloys belonging to a variety of crystal systems. This method also has the potential to be used for in situ observations of the effects of minor phases on the crystallographic behaviors of alloys. - Highlights: •A method based on 3DXRD is developed for identification of unknown minor phase. •Grain position, orientation and size, is simultaneously acquired. •A systematic simulation demonstrated the applicability of the proposed method. •Experimental results on a AA6061 sample confirmed the practicability of the method.« less

  20. Improved Bacterial and Viral Recoveries from 'Complex' Samples using Electrophoretically Assisted Acoustic Focusing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ness, K; Rose, K; Jung, B

    2008-03-27

    Automated front-end sample preparation technologies can significantly enhance the sensitivity and reliability of biodetection assays [1]. We are developing advanced sample preparation technologies for biowarfare detection and medical point-of-care diagnostics using microfluidic systems with continuous sample processing capabilities. Here we report an electrophoretically assisted acoustic focusing technique to rapidly extract and enrich viral and bacterial loads from 'complex samples', applied in this case to human nasopharyngeal samples as well as simplified surrogates. The acoustic forces capture and remove large particles (> 2 {micro}m) such as host cells, debris, dust, and pollen from the sample. We simultaneously apply an electric fieldmore » transverse to the flow direction to transport small ({le} 2 {micro}m), negatively-charged analytes into a separate purified recovery fluid using a modified H-filter configuration [Micronics US Patent 5,716,852]. Hunter and O'Brien combined transverse electrophoresis and acoustic focusing to measure the surface charge on large particles, [2] but to our knowledge, our work is the first demonstration combining these two techniques in a continuous flow device. Marina et al. demonstrated superimposed dielectrophoresis (DEP) and acoustic focusing for enhanced separations [3], but these devices have limited throughput due to the rapid decay of DEP forces. Both acoustic standing waves and electric fields exert significant forces over the entire fluid volume in microchannels, thus allowing channels with larger dimensions (> 100 {micro}m) and high throughputs (10-100 {micro}L/min) necessary to process real-world volumes (1 mL). Previous work demonstrated acoustic focusing of microbeads [4] and biological species [5] in various geometries. We experimentally characterized our device by determining the biological size-cutoff where acoustic radiation pressure forces no longer transport biological particles. Figure 1 shows images of E.Coli ({approx}1 {micro}m) and yeast ({approx}4-5 {micro}m) flowing in a microchannel (200 {micro}m deep, 500 {micro}m wide) at a flow rate of 10 {micro}L/min. The E.Coli does not focus in the acoustic field while the yeast focuses at the channel centerline. This result suggests the acoustic size-cutoff for biological particles in our device lies between 2 and 3 {micro}m. Transverse electrophoresis has been explored extensively in electric field flow fractionation [6] and isoelectric focusing devices [7]. We demonstrated transverse electrophoretic transport of a wide variety of negatively-charged species, including fluorophores, beads, viruses, E.Coli, and yeast. Figure 2 shows the electromigration of a fluorescently labeled RNA virus (MS2) from the lower half of the channel to the upper half region with continuous flow. We demonstrated the effectiveness of our electrophoretically assisted acoustic focusing device by separating virus-like particles (40 nm fluorescent beads, selected to aid in visualization) from a high background concentration of yeast contaminants (see Figure 3). Our device allows for the efficient recovery of virus into a pre-selected purified buffer while background contaminants are acoustically captured and removed. We also tested the device using clinical nasopharyngeal samples, both washes and lavages, and demonstrated removal of unknown particulates (>2 ?m size) from the sample. Our future research direction includes spiking known amounts of bacteria and viruses into clinical samples and performing quantitative off-chip analysis (real-time PCR and flow cytometry).« less

Top