Sample records for samples show good

  1. An investigation of the kinetic processes influencing mercury emissions from sand and soil samples of varying thickness.

    PubMed

    Quinones, Jason L; Carpi, Anthony

    2011-01-01

    Mercury flux from HgCl2-treated sand and untreated soil samples of varying thickness (0.5-15 mm) were measured in dark and light under a Teflon dynamic flux chamber. Mean emissions over a 5.5-d sampling period showed an increase with depth for sand samples between 0.5 and 2 mm, but increasing depth above 2 mm had no effect. First-order kinetic models showed strong goodness of fit to the data and explained a high degree ofvariability in the emissions profile of all sand samples (R = 0.70-0.98). Soil samples showed an initial emissions peak that was not correlated with depth, suggesting a very shallow process at work. However, longer-term "baseline" emissions, measured as mean emissions between days 4.5 and 5.5, did show a relationship with depth. First-order kinetic models showed good fit for soil samples up to 4 mm thick (R2 = 0.66-0.91); however, thicker samples did not show a consistent fit to first- or second-order kinetic models (1 degree R2 = 0.00-0.46; 2 degree R2 = 0.00-0.54). The data suggest that mercury emissions from soil samples may follow a multicomponent model for which more

  2. Rheology and stability kinetics of bare silicon nanoparticle inks for low-cost direct printing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    More, Priyesh V.; Jeong, Sunho; Seo, Yeong-Hui

    2013-12-16

    Highly dispersed and stable silicon nanoparticles ink is formulated for its application in direct printing or printable electronics. These dispersions are prepared from free-standing silicon nanoparticles which are not capped with any organic ligand, making it suitable for electronic applications. Silicon nanoparticles dispersions are prepared by suspending the nanoparticles in benzonitrile or ethanol by using polypropylene glycol (PPG) as a binder. All the samples show typical shear thinning behavior while the dispersion samples show low viscosities signifying good quality dispersion. Such thinning behavior favors in fabrication of dense films with spin-coating or patterns with drop casting. The dispersion stability ismore » monitored by turbiscan measurements showing good stability for one week. A low-cost direct printing method for dispersion samples is also demonstrated to obtain micro-sized patterns. Low electrical resistivity of resulting patterns, adjustable viscosity and good stability makes these silicon nanoparticles dispersions highly applicable for direct printing process.« less

  3. Use of High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS FAAS) for Sequential Multi-Element Determination of Metals in Seawater and Wastewater Samples

    NASA Astrophysics Data System (ADS)

    Peña-Vázquez, E.; Barciela-Alonso, M. C.; Pita-Calvo, C.; Domínguez-González, R.; Bermejo-Barrera, P.

    2015-09-01

    The objective of this work is to develop a method for the determination of metals in saline matrices using high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). Module SFS 6 for sample injection was used in the manual mode, and flame operating conditions were selected. The main absorption lines were used for all the elements, and the number of selected analytical pixels were 5 (CP±2) for Cd, Cu, Fe, Ni, Pb and Zn, and 3 pixels for Mn (CP±1). Samples were acidified (0.5% (v/v) nitric acid), and the standard addition method was used for the sequential determination of the analytes in diluted samples (1:2). The method showed good precision (RSD(%) < 4%, except for Pb (6.5%)) and good recoveries. Accuracy was checked after the analysis of an SPS-WW2 wastewater reference material diluted with synthetic seawater (dilution 1:2), showing a good agreement between certified and experimental results.

  4. Synthesis and property of spinel porous ZnMn2O4 microspheres

    NASA Astrophysics Data System (ADS)

    Guo, N.; Wei, X. Q.; Deng, X. L.; Xu, X. J.

    2015-11-01

    Mesoporous ternary zinc manganese oxides on the Ti sheet substrate are prepared by easy and fast hydrothermal method for the first time. The obtained ZnMn2O4 materials with homogenously distributed pores have been characterized by XRD, SEM and Raman spectra, which show the good crystal phase and particles for improving supercapacitive performance. XRD and SEM images show that the as-prepared samples have good crystallinity, and ZnMn2O4 microsphere has an average diameter of 10 μm. In addition, ZnMn2O4 are also characterized in 2 M KOH solution using three-electrode system. In the work, we study that different substrates (Ti, carbon and nickel foam) have an important effect on the electrochemical performance of the samples. The research of cyclic voltammogram (CV) indicates that the obtained specific capacitance (155 F g-1) values on nickel foam substrate for the ZnMn2O4 microspheres are higher than the values reported for some inexpensive oxides. However, the specific capacitance of all ZnMn2O4 samples has almost no change at two different scan rates which shows good long-term cycling stability. The electrochemical impedance spectroscopy with a small resistance reveals that the as-synthesized samples have good frequency response characteristics. These results indicate that the unique ZnMn2O4 electrode would be a promising electrode for high-performance supercapacitor applications.

  5. Agarose-chitosan-C18 film micro-solid phase extraction combined with high performance liquid chromatography for the determination of phenanthrene and pyrene in chrysanthemum tea samples.

    PubMed

    Ng, Nyuk Ting; Sanagi, Mohd Marsin; Wan Ibrahim, Wan Nazihah; Wan Ibrahim, Wan Aini

    2017-05-01

    Agarose-chitosan-immobilized octadecylsilyl-silica (C 18 ) film micro-solid phase extraction (μSPE) was developed and applied for the determination of phenanthrene (PHE) and pyrene (PYR) in chrysanthemum tea samples using high performance liquid chromatography-ultraviolet detection (HPLC-UV). The film of blended agarose and chitosan allows good dispersion of C 18 , prevents the leaching of C 18 during application and enhances the film mechanical stability. Important μSPE parameters were optimized including amount of sorbent loading, extraction time, desorption solvent and desorption time. The matrix match calibration curves showed good linearity (r⩾0.994) over a concentration range of 1-500ppb. Under the optimized conditions, the proposed method showed good limits of detection (0.549-0.673ppb), good analyte recoveries (100.8-105.99%) and good reproducibilities (RSDs⩽13.53%, n=3) with preconcentration factors of 4 and 72 for PHE and PYR, respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Efficient method of image edge detection based on FSVM

    NASA Astrophysics Data System (ADS)

    Cai, Aiping; Xiong, Xiaomei

    2013-07-01

    For efficient object cover edge detection in digital images, this paper studied traditional methods and algorithm based on SVM. It analyzed Canny edge detection algorithm existed some pseudo-edge and poor anti-noise capability. In order to provide a reliable edge extraction method, propose a new detection algorithm based on FSVM. Which contains several steps: first, trains classify sample and gives the different membership function to different samples. Then, a new training sample is formed by increase the punishment some wrong sub-sample, and use the new FSVM classification model for train and test them. Finally the edges are extracted of the object image by using the model. Experimental result shows that good edge detection image will be obtained and adding noise experiments results show that this method has good anti-noise.

  7. Directionally Solidified Aluminum - 7 wt% Silicon Alloys: Comparison of Earth and International Space Station Processed Samples

    NASA Technical Reports Server (NTRS)

    Grugel, Richard N,; Tewari, Surendra; Rajamure, R. S.; Erdman, Robert; Poirier, David

    2012-01-01

    Primary dendrite arm spacings of Al-7 wt% Si alloy directionally solidified in low gravity environment of space (MICAST-6 and MICAST-7: Thermal gradient approx. 19 to 26 K/cm, Growth speeds varying from 5 to 50 microns/s show good agreement with the Hunt-Lu model. Primary dendrite trunk diameters of the ISS processed samples show a good fit with a simple analytical model based on Kirkwood s approach, proposed here. Natural convection, a) decreases primary dendrite arm spacing. b) appears to increase primary dendrite trunk diameter.

  8. Polydimethylsiloxane rod extraction, a novel technique for the determination of organic micropollutants in water samples by thermal desorption-capillary gas chromatography-mass spectrometry.

    PubMed

    Montero, L; Popp, P; Paschke, A; Pawliszyn, J

    2004-01-30

    A novel, simple and inexpensive approach to absorptive extraction of organic compounds from environmental samples is presented. It consists of a polydimethylsiloxane rod used as an extraction media, enriched with analytes during shaking, then thermally desorbed and analyzed by GC-MS. Its performance was illustrated and evaluated for the enrichment of sub- to ng/l of selected chlorinated compounds (chlorobenzenes and polychlorinated biphenyls) in water samples. The new approach was compared to the stir bar sorptive extraction performance. A natural ground water sample from Bitterfeld, Germany, was also extracted using both methods, showing good agreement. The proposed approach presented good linearity, high sensitivity, good blank levels and recoveries comparable to stir bars, together with advantages such as simplicity, lower cost and higher feasibility.

  9. Antibacterial activity of crude methanolic extract and various fractions of Vitex agnus castus and Myrsine africana against clinical isolates of Methicillin Resistant Staphylococcus aureus.

    PubMed

    Ahmad, Bashir; Hafeez, Nabia; Ara, Gulshan; Azam, Sadiq; Bashir, Shumaila; Khan, Ibrar

    2016-11-01

    Staphylococcus aureus is a nosocomial pathogen that resides in the soft tissues causing many diseases. The current study was conducted to determine the prevalence of Methicillin Resistant S. aureus (MRSA) in ear discharge and pus of patients and antibacterial activity of crude methanolic extract (Cr. MeOH Ext.) and various fractions of M. Africana and V. agnus castus against clinical isolates of MRSA. A total of 40 samples were collected from ear, nose and throat (ENT) outpatient department and wards of Khyber Teaching Hospital (KTH), Peshawar. Out of 40 samples, 36 (90%) samples showed growth on Mannitol Salt Agar (MSA) media out of which 9(25%) were MRSA and the remaining 27(75%) were methicillin susceptible S. aureus (MSSA). A good antibacterial activity was observed for the Cr. MeOH Ext. (76.1%) and ethyl acetate (EtOAc) fraction of V. agnus castus against S11 (71.4%). The n-hexane fraction also showed good antibacterial effect (70%) against S 26 . The chloroform (CHCl3), butanol (BuOH) and aqueous fractions of M. africana showed good antibacterial activity against S 11 (71.4%), S32 (70%) and S 26 (75%), respectively. The above results revealed that the selected plants can be further utilized for isolation of the active ingredients as the crude extracts were found good for inhibition of MRSA.

  10. Evaluation of dried blood spot as an alternative sample collection method for hepatitis C virus RNA quantitation and genotyping using a commercial system.

    PubMed

    Mahajan, Supriya; Choudhary, Manish Chandra; Kumar, Guresh; Gupta, Ekta

    2018-06-01

    Dried blood spot (DBS) is a minimally invasive sampling method suitable for sample collection, storage and transportation in resource limited areas. Aim of this study was to compare the diagnostic utility of DBS with plasma sample for HCV RNA quantitation and genotyping using commercial systems. Plasma and DBS card spotted samples were collected from 95 HCV seropositive patients. Both types of samples were subjected to HCV RNA by real-time PCR (Abbott m2000rt, USA). Genotyping was performed using Abbott HCV genotype II kit (Abbott diagnostics, USA) in samples with viral load > 3 log 10  IU/ml. In both plasma and DBS, 14 (14.7%) samples were negative and 81 (85.3%) were positive for HCV RNA. Median viral load in plasma (3.78; range 0-7.43) log 10  IU/ml was comparable to DBS (3.93; range 0-7.24) log 10  IU/ml. DBS demonstrated sensitivity and specificity of 97.5 and 85.7% respectively, with positive predictive value (PPV) of 97.5% and negative predictive value (NPV) of 85.7%. DBS showed good correlation (r 2  = 0.866) and agreement (93.5%) with plasma. Genotyping in 20 patients showed 100% concordance between DBS and plasma samples. DBS showed good sensitivity and specificity as a sampling method for HCV RNA quantitation and genotyping.

  11. Effect of Annealing Temperature on Structural, Optical, and Electrical Properties of Sol-Gel Spin-Coating-Derived Cu2ZnSnS4 Thin Films

    NASA Astrophysics Data System (ADS)

    Hosseinpour, Rabie; Izadifard, Morteza; Ghazi, Mohammad Ebrahim; Bahramian, Bahram

    2018-02-01

    The effect of annealing temperature on structural, optical, and electrical properties of Cu2ZnSnS4 (CZTS) thin films grown on a glass substrate by spin coating sol-gel technique has been studied. Structural study showed that all samples had kesterite crystalline structure. Scanning electron microscopy images showed that the crystalline quality of the samples was improved by heat treatment. Optical study showed that the energy gap values for the samples ranged from 1.55 eV to 1.78 eV. Moreover, good optical conductivity values (1012 S-1 to 1014 S-1) were obtained for the samples. Investigation of the electrical properties of the CZTS thin films showed that the carrier concentration increased significantly with the annealing temperature. The photoelectrical behavior of the samples revealed that the photocurrent under light illumination increased significantly. Overall, the results show that the CZTS thin films annealed at 500°C had better structural, optical, and electrical properties and that such CZTS thin films are desirable for use as absorber layers in solar cells. The photovoltaic properties of the CZTS layer annealed at 500°C were also investigated and the associated figure of merit calculated. The results showed that the fabricated ZnS-CZTS heterojunction exhibited good rectifying behavior but rather low fill factor.

  12. Comparative evaluation of the COBAS AmpliPrep/COBAS TaqMan HIV type 1 test (CAP/CTM) and VERSANT HIV type 1 RNA 3.0 assay (bDNA) for quantifying HIV type 1 viral loads in China.

    PubMed

    Xu, Sihong; Song, Aijing; Nie, Jianhui; Li, Xiuhua; Li, Jingyun; Bao, Zuoyi; Wang, Youchun

    2008-11-01

    In the present study, 277 clinical samples from untreated and treated HIV-1-infected patients with different clades were used to assess the agreement between the COBAS AmpliPrep/COBAS TaqMan HIV-1 test (CAP/CTM) and VERSANT HIV-1 RNA 3.0 Assay (bDNA). A qualitative comparison of the results of the two assays showed concordance for 255 positive and 15 negative samples (94.95%, kappa = 0.798). However, seven samples with viral loads close to the lower limit of detection for CAP/CTM were negative by bDNA. A significant correlation (r = 0.881, p < 0.001) was observed for 253 samples with viral loads within the dynamic ranges of the two assays, and Bland-Altman analysis showed good agreement (96.05%) between the two assays for these 253 samples [mean (+/-2 SD), 0.389(-0.385, 1.163)]. Furthermore, ART drugs had no impact on the performances of the two assays. For samples with different clades predominant in China, the fitted regression line differed significantly from the line of equality, although significant correlations (r = 0.850-0.891, p < 0.001) and good agreements (92.86-97.25%) were found for the two assays. The mean differences for clade B' and BC samples were significant (p < 0.01). Good precision for clade B' samples was achieved for the CAP/CTM (CV: 20.73%) and bDNA (CV: 12.19%) assays. Furthermore, for clades B', BC, and AE, both assays exhibited good linearities (r = 0.9773-0.9998). Thus, the CAP/CTM and bDNA assays could be useful for quantifying HIV-1 RNA in routine clinical samples and monitoring viral loads in treated and untreated HIV-infected patients in China.

  13. A Novel Sensitive Luminescence Probe Microspheres for Rapid and Efficient Detection of τ-Fluvalinate in Taihu Lake

    PubMed Central

    Wang, Jixiang; Wang, Yunyun; Qiu, Hao; Sun, Lin; Dai, Xiaohui; Pan, Jianming; Yan, Yongsheng

    2017-01-01

    Fluorescent molecularly imprinted polymers have shown great promise in biological or chemical separations and detection, due to their high stability, selectivity and sensitivity. In this work, fluorescent molecularly imprinted microsphere was synthesized via precipitation polymerization, which could separate efficiently and rapidly detect τ-fluvalinate (a toxic insecticide) in water samples, was reported. The fluorescent imprinted sensor showed excellent stability, outstanding selectivity and the limit of detection low to 12.14 nM, good regeneration ability which still kept good sensitivity after 8 cycling experiments and fluorescence quenching mechanism was illustrated in details. In addition, the fluorescent sensor was further used to detect τ-fluvalinate in real samples from Taihu Lake. Despite the relatively complex components of the environment water, the fluorescent imprinted microspheres sitll showed good recovery, clearly demonstrating the potental value of this smart sensor nanomaterial in environment monitoring. PMID:28485402

  14. Detecting the sampling rate through observations

    NASA Astrophysics Data System (ADS)

    Shoji, Isao

    2018-09-01

    This paper proposes a method to detect the sampling rate of discrete time series of diffusion processes. Using the maximum likelihood estimates of the parameters of a diffusion process, we establish a criterion based on the Kullback-Leibler divergence and thereby estimate the sampling rate. Simulation studies are conducted to check whether the method can detect the sampling rates from data and their results show a good performance in the detection. In addition, the method is applied to a financial time series sampled on daily basis and shows the detected sampling rate is different from the conventional rates.

  15. Formulation of microemulsion propolis fluoride (PF) as varnish topical agent to stop activity of teeth caries

    NASA Astrophysics Data System (ADS)

    Sahlan, Muhamad; Prakoso, Chandra Dwi; Darwita, Risqa Rina; Hermansyah, Heri

    2017-02-01

    Topical fluoride is proven to have higher efficacy in preventing dental caries with low production cost and easy to apply. The objective of this research is to formulate alternative agent topical fluoride NH4F 5% mixed with extract ethanol propolis (EEP) in the micro-emulsion system that has high stability, antimicrobial activity, and remineralization capability to arrest teeth caries activity. By using total plate count (TPC) analysis, formulation 2.7% EEP; 6,3% surfactant; and 90,9% NH4F shows good perform to inhibit cariogenic bacteria development around 78-80%. Scanning Electron Microscopy (SEM) and Energy Dispersive X-Ray (EDX) result also showed that sample successfully remineralized enamel surface. In addition, sample showed good pH, flavonoid, and polyphenol stability for 40 days.

  16. Bioactive and biocompatible copper containing glass-ceramics with remarkable antibacterial properties and high cell viability designed for future in vivo trials.

    PubMed

    Popescu, R A; Magyari, K; Vulpoi, A; Trandafir, D L; Licarete, E; Todea, M; Ştefan, R; Voica, C; Vodnar, D C; Simon, S; Papuc, I; Baia, L

    2016-07-19

    In the present study our interest is focused on finding the efficiency of 60SiO2·(32 - x)CaO·8P2O5·xCuO (mol%) glass-ceramics, with 0 ≤ x ≤ 4 mol%, in terms of bioactivity, biocompatibility, antibacterial properties and cell viability in order to determine the most appropriate composition for their further use in in vivo trials. The sol-gel synthesized samples show a preponderantly amorphous structure with a few crystallization centers associated with the formation of an apatite and calcium carbonate crystalline phases. The Fourier Transform Infrared (FT-IR) spectra revealed slightly modified absorption bands due to the addition of copper oxide, while the information derived from the measurements performed by transmission electron microscopy, UV-vis and electron paramagnetic resonance spectroscopy showed the presence of ions and metallic copper species. X-Ray photoelectron spectroscopic analysis indicated the presence of copper metallic species, in a reduced amount, only on the sample surface with the highest Cu content. Regarding in vitro assessment of bioactivity, the results obtained by X-ray diffraction, FT-IR spectroscopy and scanning electron microscopy, demonstrated the formation of a calcium phosphate layer on all investigated sample surfaces. The inhibitory effect of the investigated samples was more significant on the Pseudomonas aeruginosa than the Staphylococcus aureus strain, the sample with the lowest concentration of copper oxide (0.5 mol%) being also the most efficient in both bacterial cultures. This sample also exhibits a very good bactericidal activity, for the other samples it was necessary to use a higher quantity to inhibit and kill the bacterial species. The secondary structure of adsorbed albumin presents few minor changes, indicating the biocompatibility of the glass-ceramics. The cell viability assay shows a good proliferation rate on samples with 0.5 and 1.5 mol% CuO, although all glass-ceramic samples exhibited a good in vivo tolerance.

  17. Comparison of analytical methods for the determination of histamine in reference canned fish samples

    NASA Astrophysics Data System (ADS)

    Jakšić, S.; Baloš, M. Ž.; Mihaljev, Ž.; Prodanov Radulović, J.; Nešić, K.

    2017-09-01

    Two screening methods for histamine in canned fish, an enzymatic test and a competitive direct enzyme-linked immunosorbent assay (CD-ELISA), were compared with the reversed-phase liquid chromatography (RP-HPLC) standard method. For enzymatic and CD-ELISA methods, determination was conducted according to producers’ manuals. For RP-HPLC, histamine was derivatized with dansyl-chloride, followed by RP-HPLC and diode array detection. Results of analysis of canned fish, supplied as reference samples for proficiency testing, showed good agreement when histamine was present at higher concentrations (above 100 mg kg-1). At a lower level (16.95 mg kg-1), the enzymatic test produced some higher results. Generally, analysis of four reference samples according to CD-ELISA and RP-HPLC showed good agreement for histamine determination (r=0.977 in concentration range 16.95-216 mg kg-1) The results show that the applied enzymatic test and CD-ELISA appeared to be suitable screening methods for the determination of histamine in canned fish.

  18. Validity Evidence of the Spanish Version of the Automatic Thoughts Questionnaire-8 in Colombia.

    PubMed

    Ruiz, Francisco J; Suárez-Falcón, Juan C; Riaño-Hernández, Diana

    2017-02-13

    The Automatic Thoughts Questionnaire (ATQ) is a widely used, 30-item, 5-point Likert-type scale that measures the frequency of negative automatic thoughts as experienced by individuals suffering from depression. However, there is some controversy about the factor structure of the ATQ, and its application can be too time-consuming for survey research. Accordingly, an abbreviated, 8-item version of the ATQ has been proposed. The aim of this study was to analyze the validity evidence of the Spanish version of the ATQ-8 in Colombia. The ATQ-8 was administered to a total of 1587 participants, including a sample of undergraduates, one of general population, and a clinical sample. The internal consistency across the different samples was good (α = .89). The one-factor model found in the original scale showed a good fit to the data (RMSEA = .083, 90% CI [.074, .092]; CFI = .96; NNFI = .95). The clinical sample's mean score on the ATQ-8 was significantly higher than the scores of the nonclinical samples. The ATQ-8 was sensitive to the effects of a 1-session acceptance and commitment therapy focused on disrupting negative repetitive thinking. ATQ-8 scores were significantly related to dysfunctional schemas, emotional symptoms, mindfulness, experiential avoidance, satisfaction with life, and dysfunctional attitudes. In conclusion, the Spanish version of the ATQ-8 showed good psychometric properties in Colombia.

  19. Packed in-tube solid phase microextraction with graphene oxide supported on aminopropyl silica: Determination of target triazines in water samples.

    PubMed

    De Toffoli, Ana L; Fumes, Bruno H; Lanças, Fernando M

    2018-02-22

    On-line in-tube solid phase microextraction (in-tube SPME) coupled to high performance liquid chromatography and tandem mass spectrometry (HPLC-MS/MS) was successfully applied to the determination of selected triazines in water samples. The method based on the employment of a packed column containing graphene oxide (GO) supported on aminopropyl silica (Si) showed that the extraction phase has a high potential for triazines extraction aiming to its physical-chemical properties including ultrahigh specific surface area, good mechanical and thermal stability and high fracture strength. Injection volume and loading time were both investigated and optimized. The method validation using Si-GO to extract and concentrate the analytes showed satisfactory results, good sensitivity, good linearity (0.2-4.0 µg L -1 ) and low detection limits (1.1-2.9 ng L -1 ). The high extraction efficiency was determined with enrichment factors ranging from 1.2-2.9 for the lowest level, 1.3-4.9 intermediate level and 1.2-3.0 highest level (n = 3). Although the analytes were not detected in the real samples evaluated, the method has demonstrated to be efficient through its application in the analysis of spiked triazines in ground and mineral water samples.

  20. Hypercrosslinked particles for the extraction of sweeteners using dispersive solid-phase extraction from environmental samples.

    PubMed

    Lakade, Sameer S; Zhou, Qing; Li, Aimin; Borrull, Francesc; Fontanals, Núria; Marcé, Rosa M

    2018-04-01

    This work presents a new extraction material, namely, Q-100, based on hypercrosslinked magnetic particles, which was tested in dispersive solid-phase extraction for a group of sweeteners from environmental samples. The hypercrosslinked Q-100 magnetic particles had the advantage of suitable pore size distribution and high surface area, and showed good retention behavior toward sweeteners. Different dispersive solid-phase extraction parameters such as amount of magnetic particles or extraction time were optimized. Under optimum conditions, Q-100 showed suitable apparent recovery, ranging in the case of river water sample from 21 to 88% for all the sweeteners, except for alitame (12%). The validated method based on dispersive solid-phase extraction using Q-100 followed by liquid chromatography with tandem mass spectrometry provided good linearity and limits of quantification between 0.01 and 0.1 μg/L. The method was applied to analyze samples from river water and effluent wastewater, and four sweeteners (acesulfame, saccharin, cyclamate, and sucralose) were found in both types of sample. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gajjar, Anant; /Liverpool U.

    Measurements of the di-photon cross section have been made in the central region and are found to be in good agreement with NLO QCD predictions. The cross section of events containing a photon and additional heavy flavor jet have also been measured, as well as the ratio of photon + b to photon + c. The statistically limited sample shows good agreement with Leading Order predictions.

  2. Psychometric properties of the Geriatric Anxiety Inventory (GAI) and its short-form (GAI-SF) in a clinical and non-clinical sample of older adults.

    PubMed

    Johnco, Carly; Knight, Ashleigh; Tadic, Dusanka; Wuthrich, Viviana M

    2015-07-01

    The Geriatric Anxiety Inventory is a 20-item geriatric-specific measure of anxiety severity. While studies suggest good internal consistency and convergent validity, divergent validity from measures of depression are weak. Clinical cutoffs have been developed that vary across studies due to the small clinical samples used. A six-item short form (GAI-SF) has been developed, and while this scale is promising, the research assessing the psychometrics of this scale is limited. This study examined the psychometric properties of GAI and GAI-SF in a large sample of 197 clinical geriatric participants with a comorbid anxiety and unipolar mood disorder, and a non-clinical control sample (N = 59). The internal consistency and convergent validity with other measures of anxiety was adequate for GAI and GAI-SF. Divergent validity from depressive symptoms was good in the clinical sample but weak in the total and non-clinical samples. Divergent validity from cognitive functioning was good in all samples. The one-factor structure was replicated for both measures. Receiver Operating Characteristic analyses indicated that the GAI is more accurate at identifying clinical status than the GAI-SF, although the sensitivity and specificity for the recommended cutoffs was adequate for both measures. Both GAI and GAI-SF show good psychometric properties for identifying geriatric anxiety. The GAI-SF may be a useful alternative screening measure for identifying anxiety in older adults.

  3. Adaptation and Validation of the Sexual Assertiveness Scale (SAS) in a Sample of Male Drug Users.

    PubMed

    Vallejo-Medina, Pablo; Sierra, Juan Carlos

    2015-04-21

    The aim of the present study was to adapt and validate the Sexual Assertiveness Scale (SAS) in a sample of male drug users. A sample of 326 male drug users and 322 non-clinical males was selected by cluster sampling and convenience sampling, respectively. Results showed that the scale had good psychometric properties and adequate internal consistency reliability (Initiation = .66, Refusal = .74 and STD-P = .79). An evaluation of the invariance showed strong factor equivalence between both samples. A high and moderate effect of Differential Item Functioning was only found in items 1 and 14 (∆R 2 Nagelkerke = .076 and .037, respectively). We strongly recommend not using item 1 if the goal is to compare the scores of both groups, otherwise the comparison will be biased. Correlations obtained between the CSFQ-14 and the safe sex ratio and the SAS subscales were significant (CI = 95%) and indicated good concurrent validity. Scores of male drug users were similar to those of non-clinical males. Therefore, the adaptation of the SAS to drug users provides enough guarantees for reliable and valid use in both clinical practice and research, although care should be taken with item 1.

  4. ZnO nanorod array polydimethylsiloxane composite solid phase micro-extraction fiber coating: fabrication and extraction capability.

    PubMed

    Wang, Dan; Wang, Qingtang; Zhang, Zhuomin; Chen, Guonan

    2012-01-21

    ZnO nanorod array coating is a novel kind of solid-phase microextraction (SPME) fiber coating which shows good extraction capability due to the nanostructure. To prepare the composite coating is a good way to improve the extraction capability. In this paper, the ZnO nanorod array polydimethylsiloxane (PDMS) composite SPME fiber coating has been prepared and its extraction capability for volatile organic compounds (VOCs) has been studied by headspace sampling the typical volatile mixed standard solution of benzene, toluene, ethylbenzene and xylene (BTEX). Improved detection limit and good linear ranges have been achieved for this composite SPME fiber coating. Also, it is found that the composite SPME fiber coating shows good extraction selectivity to the VOCs with alkane radicals.

  5. Groundwater quality assessment using geospatial and statistical tools in Salem District, Tamil Nadu, India

    NASA Astrophysics Data System (ADS)

    Arulbalaji, P.; Gurugnanam, B.

    2017-10-01

    The water quality study of Salem district, Tamil Nadu has been carried out to assess the water quality for domestic and irrigation purposes. For this purpose, 59 groundwater samples were collected and analyzed for pH, electrical conductivity (EC), total dissolved solids (TDS), major anions (HCO3 -, CO3 -, F-, Cl-, NO2 - + NO3 -, and SO4 2-), major cations (Ca2+ Mg2+, Na+, and K+), alkalinity (ALK), and hardness (HAR). To assess the water quality, the following chemical parameters were calculated based on the analytical results, such as Piper plot, water quality index (WQI), sodium adsorption ratio (SAR), magnesium hazard (MH), Kelly index (KI), and residual sodium carbonate (RSC). Wilcox diagram represents that 23% of the samples are excellent to good, 40% of the samples are good to permissible, 10% of the samples are permissible to doubtful, 24% of the samples are doubtful unsuitable, and only 3% of the samples are unsuitable for irrigation. SAR values shows that 52% of the samples indicate high-to-very high and low-to-medium alkali water. KI values indicate good quality (30%) and not suitable (70%) for irrigation purposes. RSC values indicate that 89% of samples are suitable for irrigation purposes. MH reveals that 17% suitable and 83% samples are not suitable for irrigation purposes and for domestic purposes the excellent (8%), good (48%), and poor (44%). The agricultural waste, fertilizer used, soil leaching, urban runoff, livestock waste, and sewages are the sources of poor water quality. Some samples are not suitable for irrigation purposes due to high salinity, hardness, and magnesium concentration. In general, the groundwater of the Salem district was polluted by agricultural activities, anthropogenic activities, ion exchange, and weathering.

  6. [Identification of Good-Practice Projects in Promoting Physical Activity - Methods, Pitfalls and Sampled Outcomes].

    PubMed

    Henn, Annette; Karger, Claudia; Wöhlken, Katrin; Meier, Diana; Ungerer-Röhrich, Ulrike; Graf, Christine; Woll, Alexander

    2017-03-01

    The aim of this paper is to identify and show examples of good practice of public health promotion. For this, uniform quality criteria were worked out under consideration of national and international scientific literature.For the identification of examples of good practice, a comparison of different quality criteria was carried out and combined with each other in a first step. In the following step, examples of good practice were identified after a comprehensive search. The choice of the "good-practice" projects is exemplary and lays no claim to completeness.6 main quality criteria (QC) of programs promoting physical activity could be identified in the national and international context. The analysis showed altogether 10 projects which can exemplarily be classified as examples of good practice of the target groups of children and teenagers, adults, older people and people with pre-existing illnesses. These projects, however, show major differences in their (methodological) quality.The analysis reports a lack of "Good-Practice" examples. Deficits lie mainly in documentation and sustainability. Because of incomplete documentation, an assessment as a "Good-Practice" example is only possible to a limited extent; a lot of information, particularly in the evaluation, is missing. © Georg Thieme Verlag KG Stuttgart · New York.

  7. The clustering evolution of distant red galaxies in the GOODS-MUSIC sample

    NASA Astrophysics Data System (ADS)

    Grazian, A.; Fontana, A.; Moscardini, L.; Salimbeni, S.; Menci, N.; Giallongo, E.; de Santis, C.; Gallozzi, S.; Nonino, M.; Cristiani, S.; Vanzella, E.

    2006-07-01

    Aims.We study the clustering properties of Distant Red Galaxies (DRGs) to test whether they are the progenitors of local massive galaxies. Methods.We use the GOODS-MUSIC sample, a catalog of ~3000 Ks-selected galaxies based on VLT and HST observation of the GOODS-South field with extended multi-wavelength coverage (from 0.3 to 8~μm) and accurate estimates of the photometric redshifts to select 179 DRGs with J-Ks≥ 1.3 in an area of 135 sq. arcmin.Results.We first show that the J-Ks≥ 1.3 criterion selects a rather heterogeneous sample of galaxies, going from the targeted high-redshift luminous evolved systems, to a significant fraction of lower redshift (1

  8. [Standard sample preparation method for quick determination of trace elements in plastic].

    PubMed

    Yao, Wen-Qing; Zong, Rui-Long; Zhu, Yong-Fa

    2011-08-01

    Reference sample was prepared by masterbatch method, containing heavy metals with known concentration of electronic information products (plastic), the repeatability and precision were determined, and reference sample preparation procedures were established. X-Ray fluorescence spectroscopy (XRF) analysis method was used to determine the repeatability and uncertainty in the analysis of the sample of heavy metals and bromine element. The working curve and the metrical methods for the reference sample were carried out. The results showed that the use of the method in the 200-2000 mg x kg(-1) concentration range for Hg, Pb, Cr and Br elements, and in the 20-200 mg x kg(-1) range for Cd elements, exhibited a very good linear relationship, and the repeatability of analysis methods for six times is good. In testing the circuit board ICB288G and ICB288 from the Mitsubishi Heavy Industry Company, results agreed with the recommended values.

  9. Reliability and validity of a Chinese version of the Diagnostic Interview for Borderlines-Revised.

    PubMed

    Wang, Lanlan; Yuan, Chenmei; Qiu, Jianying; Gunderson, John; Zhang, Min; Jiang, Kaida; Leung, Freedom; Zhong, Jie; Xiao, Zeping

    2014-09-01

    Borderline personality disorder (BPD) is the most studied of the axis II disorders. One of the most widely used diagnostic instruments is the Diagnostic Interview for Borderline Patients-Revised (DIB-R). The aim of this study was to test the reliability and validity of DIB-R for use in the Chinese culture. The reliability and validity of the DIB-R Chinese version were assessed in a sample of 236 outpatients with a probable BPD diagnosis. The Structured Clinical Interview for DSM-IV Personality Disorders (SCID-II) was used as a standard. Test-retest reliability was tested six months later with 20 patients, and inter-rater reliability was tested on 32 patients. The Chinese version of the DIB-R showed good internal global consistency (Cronbach's α of 0.916), good test-retest reliability (Pearson correlation of 0.704), good inter-rater reliability (intra-class correlation coefficient of 0.892 and kappa of 0.861). When compared with the DSM-IV diagnosis as measured by the SCID-II, the DIB-R showed relatively good sensitivity (0.768) and specificity (0.891) at the cutoff of 7, moderate diagnostic convergence (kappa of 0.631), as well as good discriminating validity. The Chinese version of the DIB-R has good psychometric properties, which renders it a valuable method for examining the presence, the severity, and component phenotypes of BPD in Chinese samples. © 2013 Wiley Publishing Asia Pty Ltd.

  10. [Inter-rater reliability and validity of the OPD-CA axes structure and conflict].

    PubMed

    Benecke, Cord; Bock, Astrid; Wieser, Elke; Tschiesner, Reinhard; Lochmann, Martha; Küspert, Felicia; Schorn, Robert; Viertler, Bernhard; Steinmayr-Gensluckner, Maria

    2011-01-01

    The manual of the Operationalized Psychodynamic Diagnostics in childhood and adolescence (OPD-CA) is an instrument meanwhile widespread in the clinical practice to assess psychodynamic dimensions. Publications of inter-rater agreement and validity are still outstanding. This study assessed the interrater-reliability and validity for the axis structure and the axis conflict. 60 adolescents between 14 and 17 years, with and without psychic disorders, were diagnosed with the Operationalized Psychodynamic Diagnostics in childhood and adolescence (Arbeitskreis OPD-KJ, 2007) and SCID-II-interviews and questionnaires. A partial sample of 36 OPD-CA-interviews was the data basis for the assessment of inter-rater agreement. Calculations of validity for axis structure and axis conflict were made with the whole sample. Inter-rater agreement for the axis structure and the axis conflict showed good to very good weighted Kappa coefficients among the trained raters. Validity of the axis structure showed good results. The Operationalized Psychodynamic Diagnostics in childhood and adolescence (OPD-CA) allows a reliable diagnostic of axis structure and axis conflict, if the ratings are done on the basis of semistructured videotaped interviews by trained raters. The axis structure shows validity, while the results concerning the validity of the axis conflict remain unclear.

  11. Permethylated-β-Cyclodextrin Capped CdTe Quantum Dot and its Sensitive Fluorescence Analysis of Malachite Green.

    PubMed

    Cao, Yujuan; Wei, Jiongling; Wu, Wei; Wang, Song; Hu, Xiaogang; Yu, Ying

    2015-09-01

    In the present work, the CdTe quantum dots were covalently conjugated with permethylated-β-cyclodextrin (OMe-β-CD) using 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride as cross-linking reagent. The obtained functional quantum dots (OMe-β-CD/QDs) showed highly luminescent, water solubility and photostability as well as good inclusion ability to malachite green. A sensitive fluorescence method was developed for the analysis of malachite green in different samples. The good linearity was 2.0 × 10(-7)-1.0 × 10(-5) mol/L and the limit of detect was 1.7 × 10(-8) mol/L. The recoveries for three environmental water samples were 92.0-108.2 % with relative standard deviation (RSD) of 0.24-1.87 %, while the recovery for the fish sample was 94.3 % with RSD of 1.04 %. The results showed that the present method was sensitive and convenient to determine malachite green in complex samples. Graphical Abstract The analytical mechanism of OMe-β-CD/QDs and its linear response to MG.

  12. Application of Taguchi L16 design method for comparative study of ability of 3A zeolite in removal of Rhodamine B and Malachite green from environmental water samples.

    PubMed

    Rahmani, Mashaallah; Kaykhaii, Massoud; Sasani, Mojtaba

    2018-01-05

    This study aimed to investigate the efficiency of 3A zeolite as a novel adsorbent for removal of Rhodamine B and Malachite green dyes from water samples. To increase the removal efficiency, effecting parameters on adsorption process were investigated and optimized by adopting Taguchi design of experiments approach. The percentage contribution of each parameter on the removal of Rhodamine B and Malachite green dyes determined using ANOVA and showed that the most effective parameters in removal of RhB and MG by 3A zeolite are initial concentration of dye and pH, respectively. Under optimized condition, the amount predicted by Taguchi design method and the value obtained experimentally, showed good closeness (more than 94.86%). Good adsorption efficiency obtained for proposed methods indicates that, the 3A zeolite is capable to remove the significant amounts of Rhodamine B and Malachite green from environmental water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Application of Taguchi L16 design method for comparative study of ability of 3A zeolite in removal of Rhodamine B and Malachite green from environmental water samples

    NASA Astrophysics Data System (ADS)

    Rahmani, Mashaallah; Kaykhaii, Massoud; Sasani, Mojtaba

    2018-01-01

    This study aimed to investigate the efficiency of 3A zeolite as a novel adsorbent for removal of Rhodamine B and Malachite green dyes from water samples. To increase the removal efficiency, effecting parameters on adsorption process were investigated and optimized by adopting Taguchi design of experiments approach. The percentage contribution of each parameter on the removal of Rhodamine B and Malachite green dyes determined using ANOVA and showed that the most effective parameters in removal of RhB and MG by 3A zeolite are initial concentration of dye and pH, respectively. Under optimized condition, the amount predicted by Taguchi design method and the value obtained experimentally, showed good closeness (more than 94.86%). Good adsorption efficiency obtained for proposed methods indicates that, the 3A zeolite is capable to remove the significant amounts of Rhodamine B and Malachite green from environmental water samples.

  14. The Parent-Version of the Spence Children's Anxiety Scale (SCAS-P) in Chinese and Italian Community Samples: Validation and Cross-Cultural Comparison.

    PubMed

    Li, Jian-Bin; Delvecchio, Elisa; Di Riso, Daniela; Nie, Yan-Gang; Lis, Adriana

    2016-06-01

    The current study aimed to validate the parent-version of the Spence Children's Anxiety Scale (SCAS-P) among Chinese and Italian community adolescents and to compare adolescents' anxiety symptoms in these two countries. Chinese (N = 456) and Italian (N = 452) adolescents and their parents participated in the study. Results showed that: (1) the six correlated-factor structure was demonstrated and invariant across countries. (2) The reliability of the total scale was good in both samples, whereas reliabilities of subscales were acceptable and moderate in Chinese and Italian samples, respectively. (3) The SCAS-P showed good convergent and divergent validity. (4) Adolescent-parent agreement was from low to medium while mother-father agreement ranged from medium to high. (5) There were cultural and gender differences in levels of parent-report anxiety symptoms. In conclusion, SCAS-P seems to be a promising parent-report instrument to assess Chinese and Italian adolescents' anxiety symptoms.

  15. A more rational, theory-driven approach to analysing the factor structure of the Edinburgh Postnatal Depression Scale.

    PubMed

    Kozinszky, Zoltan; Töreki, Annamária; Hompoth, Emőke A; Dudas, Robert B; Németh, Gábor

    2017-04-01

    We endeavoured to analyze the factor structure of the Edinburgh Postnatal Depression Scale (EPDS) during a screening programme in Hungary, using exploratory (EFA) and confirmatory factor analysis (CFA), testing both previously published models and newly developed theory-driven ones, after a critical analysis of the literature. Between April 2011 and January 2015, a sample of 2967 pregnant women (between 12th and 30th weeks of gestation) and 714 women 6 weeks after delivery completed the Hungarian version of the EPDS in South-East Hungary. EFAs suggested unidimensionality in both samples. 33 out of 42 previously published models showed good and 6 acceptable fit with our antepartum data in CFAs, whilst 10 of them showed good and 28 acceptable fit in our postpartum sample. Using multiple fit indices, our theory-driven anhedonia (items 1,2) - anxiety (items 4,5) - low mood (items 8,9) model provided the best fit in the antepartum sample. In the postpartum sample, our theory-driven models were again among the best performing models, including an anhedonia and an anxiety factor together with either a low mood or a suicidal risk factor (items 3,6,10). The EPDS showed moderate within- and between-culture invariability, although this would also need to be re-examined with a theory-driven approach. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  16. Biodiversity of benthic macroinvertebrates in Air Terjun Asahan, Asahan, Melaka, Malaysia

    NASA Astrophysics Data System (ADS)

    Nurhafizah-Azwa, S.; Ahmad A., K.

    2016-11-01

    A study on benthic macroinvertebrate diversity was conducted at Air Terjun Asahan, Asahan, Melaka. Five stations were selected with distance intervals of approximately 500 metres. Three replicates of benthic macroinvertebrate and water samples were taken. Results classified Air Terjun Asahan in class II, which indicated good water quality based on WQI recommended by the Department of Environment. A total of 1 phylum, 2 classes, 6 order, 30 families, and 2183 individuals were successfully sampled and recorded. The analysis showed that the average value of Shannon Diversity Index, H' (2.19), Pielou Evenness Index, J' (0.30), and Margaleff Richness Index, DMG (3.77) described that Air Terjun Asahan was in moderate condition and the distribution of macroinvertebrates was uniform between stations. Correlation test showed that the WQI had a strong relationship with the diversity indices involved. BMWP, and FBI showed that Air Terjun Asahan was in good water quality. CCA test was conducted to show environmental factors towards benthic macroinvertebrate distribution. The presence of Leptophlebiidae, Baetidae, Heptageniidae and Chironomidae with high abundance of the families showed the potential as biological indicators of a clean ecosystem.

  17. Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection

    PubMed Central

    Ruman, Marek; Narkowicz, Sylwia; Namieśnik, Jacek

    2017-01-01

    A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1–100 μg/L for urine, 5–100 μg/L for saliva, and 3–100 μg/L for sweat samples with determination coefficients (R) > 0.992. Low detection limits (LODs) in the range of 1.8 μg/L, 5.1 μg/L, and 5.8 μg/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n = 3) were obtained. The proposed method has been successfully applied to the analysis of human biological samples. PMID:29348966

  18. Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection.

    PubMed

    Jaszczak, Ewa; Ruman, Marek; Narkowicz, Sylwia; Namieśnik, Jacek; Polkowska, Żaneta

    2017-01-01

    A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1-100  μ g/L for urine, 5-100  μ g/L for saliva, and 3-100  μ g/L for sweat samples with determination coefficients ( R ) > 0.992. Low detection limits (LODs) in the range of 1.8  μ g/L, 5.1  μ g/L, and 5.8  μ g/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n = 3) were obtained. The proposed method has been successfully applied to the analysis of human biological samples.

  19. Highly Transparent Wafer-Scale Synthesis of Crystalline WS2 Nanoparticle Thin Film for Photodetector and Humidity-Sensing Applications.

    PubMed

    Pawbake, Amit S; Waykar, Ravindra G; Late, Dattatray J; Jadkar, Sandesh R

    2016-02-10

    In the present investigation, we report a one-step synthesis method of wafer-scale highly crystalline tungsten disulfide (WS2) nanoparticle thin film by using a modified hot wire chemical vapor deposition (HW-CVD) technique. The average size of WS2 nanoparticle is found to be 25-40 nm over an entire 4 in. wafer of quartz substrate. The low-angle XRD data of WS2 nanoparticle shows the highly crystalline nature of sample along with orientation (002) direction. Furthermore, Raman spectroscopy shows two prominent phonon vibration modes of E(1)2g and A1g at ∼356 and ∼420 cm(-1), respectively, indicating high purity of material. The TEM analysis shows good crystalline quality of sample. The synthesized WS2 nanoparticle thin film based device shows good response to humidity and good photosensitivity along with good long-term stability of the device. It was found that the resistance of the films decreases with increasing relative humidity (RH). The maximum humidity sensitivity of 469% along with response time of ∼12 s and recovery time of ∼13 s were observed for the WS2 thin film humidity sensor device. In the case of photodetection, the response time of ∼51 s and recovery time of ∼88 s were observed with sensitivity ∼137% under white light illumination. Our results open up several avenues to grow other transition metal dichalcogenide nanoparticle thin film for large-area nanoelectronics as well as industrial applications.

  20. Reflexion on linear regression trip production modelling method for ensuring good model quality

    NASA Astrophysics Data System (ADS)

    Suprayitno, Hitapriya; Ratnasari, Vita

    2017-11-01

    Transport Modelling is important. For certain cases, the conventional model still has to be used, in which having a good trip production model is capital. A good model can only be obtained from a good sample. Two of the basic principles of a good sampling is having a sample capable to represent the population characteristics and capable to produce an acceptable error at a certain confidence level. It seems that this principle is not yet quite understood and used in trip production modeling. Therefore, investigating the Trip Production Modelling practice in Indonesia and try to formulate a better modeling method for ensuring the Model Quality is necessary. This research result is presented as follows. Statistics knows a method to calculate span of prediction value at a certain confidence level for linear regression, which is called Confidence Interval of Predicted Value. The common modeling practice uses R2 as the principal quality measure, the sampling practice varies and not always conform to the sampling principles. An experiment indicates that small sample is already capable to give excellent R2 value and sample composition can significantly change the model. Hence, good R2 value, in fact, does not always mean good model quality. These lead to three basic ideas for ensuring good model quality, i.e. reformulating quality measure, calculation procedure, and sampling method. A quality measure is defined as having a good R2 value and a good Confidence Interval of Predicted Value. Calculation procedure must incorporate statistical calculation method and appropriate statistical tests needed. A good sampling method must incorporate random well distributed stratified sampling with a certain minimum number of samples. These three ideas need to be more developed and tested.

  1. Possibility of successive SRXFA use along with chemical-spectral methods for palladium analysis in geological samples

    NASA Astrophysics Data System (ADS)

    Kislov, E. V.; Kulikov, A. A.; Kulikova, A. B.

    1989-10-01

    Samples of basit-ultrabasit rocks and NiCu ores of the Ioko-Dovyren and Chaya massifs were analysed by SRXFA and a chemical-spectral method. SRXFA perfectly satisfies the quantitative noble-metals analysis of ore-free rocks. Combination of SRXFA and chemical-spectral analysis has good prospects. After analysis of a great number of samples by SRXFA it is necessary to select samples which would show minimal and maximal results for the chemical-spectral method.

  2. Ion exchangers in radioactive waste management: natural Iranian zeolites.

    PubMed

    Nilchi, A; Maalek, B; Khanchi, A; Ghanadi Maragheh, M; Bagheri, A; Savoji, K

    2006-01-01

    Five samples of natural zeolites from different parts of Iran were chosen for this study. In order to characterize and determine their structures, X-ray diffraction and infrared spectrometry were carried out for each sample. The selective absorption properties of each zeolite were found by calculating the distribution coefficient (K(d)) of various simulated wastes which were prepared by spiking the radionuclides with (131)I, (99)Mo, (153)Sm, (140)La and (147)Nd. All the zeolite samples used in this study had extremely high absorption value towards (140)La; clinoptolite from Mianeh and analsite from Ghalehkhargoshi showed good absorption for (147)Nd; clinoptolite from Semnan and clinoptolite from Firozkoh showed high absorption for (153)Sm; mesolite from Arababad Tabas showed good absorption for (99)Mo; and finally mesolite from Arababad Tabas, clinoptolite from Semnan and clinoptolite from Firozkoh could be used to selectively absorb (131)I from the stimulated waste which was prepared. The natural zeolites chosen for these studies show a similar pattern to those synthetic ion exchangers in the literature and in some cases an extremely high selectivity towards certain radioactive elements. Hence the binary separation of radioactive elements could easily be carried out. Furthermore, these zeolites, which are naturally occurring ion exchangers, are viable economically and extremely useful alternatives in this industry.

  3. Pressure of the hot gas in simulations of galaxy clusters

    NASA Astrophysics Data System (ADS)

    Planelles, S.; Fabjan, D.; Borgani, S.; Murante, G.; Rasia, E.; Biffi, V.; Truong, N.; Ragone-Figueroa, C.; Granato, G. L.; Dolag, K.; Pierpaoli, E.; Beck, A. M.; Steinborn, Lisa K.; Gaspari, M.

    2017-06-01

    We analyse the radial pressure profiles, the intracluster medium (ICM) clumping factor and the Sunyaev-Zel'dovich (SZ) scaling relations of a sample of simulated galaxy clusters and groups identified in a set of hydrodynamical simulations based on an updated version of the treepm-SPH GADGET-3 code. Three different sets of simulations are performed: the first assumes non-radiative physics, the others include, among other processes, active galactic nucleus (AGN) and/or stellar feedback. Our results are analysed as a function of redshift, ICM physics, cluster mass and cluster cool-coreness or dynamical state. In general, the mean pressure profiles obtained for our sample of groups and clusters show a good agreement with X-ray and SZ observations. Simulated cool-core (CC) and non-cool-core (NCC) clusters also show a good match with real data. We obtain in all cases a small (if any) redshift evolution of the pressure profiles of massive clusters, at least back to z = 1. We find that the clumpiness of gas density and pressure increases with the distance from the cluster centre and with the dynamical activity. The inclusion of AGN feedback in our simulations generates values for the gas clumping (√{C}_{ρ }˜ 1.2 at R200) in good agreement with recent observational estimates. The simulated YSZ-M scaling relations are in good accordance with several observed samples, especially for massive clusters. As for the scatter of these relations, we obtain a clear dependence on the cluster dynamical state, whereas this distinction is not so evident when looking at the subsamples of CC and NCC clusters.

  4. Validation of the Self-Beliefs Related to Social Anxiety Scale

    PubMed Central

    Moulds, Michelle L.; Rapee, Ronald M.

    2014-01-01

    The importance of self-beliefs in prominent models of social phobia has led to the development of measures that tap this cognitive construct. The Self-Beliefs Related to Social Anxiety (SBSA) Scale is one such measure and taps the three maladaptive belief types proposed in Clark and Wells’s model of social phobia. This study aimed to replicate and extend previous research on the psychometric properties of the SBSA. Replicating previous research, in an (undiagnosed) undergraduate sample (n = 235), the SBSA was found to have a correlated three-factor structure using confirmatory factor analyses, and the SBSA and its subscales demonstrated good internal consistency and test–retest reliability. The SBSA and its subscales also had unique relationships with social anxiety and depression, the majority of which replicated previous research. Extending previous research, the SBSA and its subscales showed good incremental validity in the undergraduate sample and good discriminative validity using the undergraduate sample and a sample of individuals with social phobia (n = 33). The SBSA’s strong theoretical basis and the findings of this study suggest that the SBSA is an ideal research and clinical tool to assess the cognitions characteristic of social phobia. PMID:23575344

  5. Validation of the self-beliefs related to social anxiety scale: a replication and extension.

    PubMed

    Wong, Quincy J J; Moulds, Michelle L; Rapee, Ronald M

    2014-06-01

    The importance of self-beliefs in prominent models of social phobia has led to the development of measures that tap this cognitive construct. The Self-Beliefs Related to Social Anxiety (SBSA) Scale is one such measure and taps the three maladaptive belief types proposed in Clark and Wells's model of social phobia. This study aimed to replicate and extend previous research on the psychometric properties of the SBSA. Replicating previous research, in an (undiagnosed) undergraduate sample (n = 235), the SBSA was found to have a correlated three-factor structure using confirmatory factor analyses, and the SBSA and its subscales demonstrated good internal consistency and test-retest reliability. The SBSA and its subscales also had unique relationships with social anxiety and depression, the majority of which replicated previous research. Extending previous research, the SBSA and its subscales showed good incremental validity in the undergraduate sample and good discriminative validity using the undergraduate sample and a sample of individuals with social phobia (n = 33). The SBSA's strong theoretical basis and the findings of this study suggest that the SBSA is an ideal research and clinical tool to assess the cognitions characteristic of social phobia. © The Author(s) 2013.

  6. Good soldiers and good actors: prosocial and impression management motives as interactive predictors of affiliative citizenship behaviors.

    PubMed

    Grant, Adam M; Mayer, David M

    2009-07-01

    Researchers have discovered inconsistent relationships between prosocial motives and citizenship behaviors. We draw on impression management theory to propose that impression management motives strengthen the association between prosocial motives and affiliative citizenship by encouraging employees to express citizenship in ways that both "do good" and "look good." We report 2 studies that examine the interactions of prosocial and impression management motives as predictors of affiliative citizenship using multisource data from 2 different field samples. Across the 2 studies, we find positive interactions between prosocial and impression management motives as predictors of affiliative citizenship behaviors directed toward other people (helping and courtesy) and the organization (initiative). Study 2 also shows that only prosocial motives predict voice-a challenging citizenship behavior. Our results suggest that employees who are both good soldiers and good actors are most likely to emerge as good citizens in promoting the status quo.

  7. Analytical parameters of the microplate-based ORAC-pyrogallol red assay.

    PubMed

    Ortiz, Rocío; Antilén, Mónica; Speisky, Hernán; Aliaga, Margarita E; López-Alarcón, Camilo

    2011-01-01

    The analytical parameters of the microplate-based oxygen radicals absorbance capacity (ORAC) method using pyrogallol red (PGR) as probe (ORAC-PGR) are presented. In addition, the antioxidant capacity of commercial beverages, such as wines, fruit juices, and iced teas, is estimated. A good linearity of the area under the curve (AUC) versus Trolox concentration plots was obtained [AUC = (845 +/- 110) + (23 +/- 2) [Trolox, microM], R = 0.9961, n = 19]. QC experiments showed better precision and accuracy at the highest Trolox concentration (40 microM) with RSD and REC (recuperation) values of 1.7 and 101.0%, respectively. When red wine was used as sample, the method also showed good linearity [AUC = (787 +/- 77) + (690 +/- 60) [red wine, microL/mL]; R = 0.9926, n = 17], precision and accuracy with RSD values from 1.4 to 8.3%, and REC values that ranged from 89.7 to 103.8%. Additivity assays using solutions containing gallic acid and Trolox (or red wine) showed an additive protection of PGR given by the samples. Red wines showed higher ORAC-PGR values than white wines, while the ORAC-PGR index of fruit juices and iced teas presented a great variability, ranging from 0.6 to 21.6 mM of Trolox equivalents. This variability was also observed for juices of the same fruit, showing the influence of the brand on the ORAC-PGR index. The ORAC-PGR methodology can be applied in a microplate reader with good linearity, precision, and accuracy.

  8. The silvicultural implications of age patterns in two southern pine stands after 72 years of uneven-aged management

    Treesearch

    Don C. Bragg; James M. Guldin

    2015-01-01

    A randomized sample of 250 loblolly (Pinus taeda L.) and shortleaf (Pinus echinata Mill.) pine ring counts was collected from the Good and Poor Farm Forestry compartments on the Crossett Experimental Forest. These mature, pine-dominated stands have been managed using uneven-aged silviculture since 1937. Our sample shows that both...

  9. Effect of sample preparation on the measurement of sugars, organic acids, and polyphenols in apple fruit by mid-infrared spectroscopy.

    PubMed

    Bureau, Sylvie; Scibisz, Iwona; Le Bourvellec, Carine; Renard, Catherine M G C

    2012-04-11

    The objectives of this study were (i) to test different conditions of freezing, thawing, and grinding during sample preparation and (ii) to evaluate the possibility of using mid-infrared spectroscopy for analyzing the composition of sugars, organic acids, and polyphenols in apples. Seven commercial apple cultivars were chosen for their large variability in composition (total polyphenols from 406 to 1033 mg kg(-1) fresh weight). The different conditions of sample preparation affected only the phenolic compounds and not sugars or organic acids. The regression models of the mid-infrared spectra showed a good ability to estimate sugar and organic acid contents (R(2) ≥ 0.96), except for citric acid. Good predictions were obtained for total phenolic, flavan-3-ols, and procyanidins (R(2) ≥ 0.94) provided oxidation was avoided during sample preparation. A rapid and simple procedure was then proposed for phenolic compounds using sodium fluoride during sample homogenization at ambient temperature and freeze-drying before spectra acquisition.

  10. In vitro physicochemical, phytochemical and functional properties of fiber rich fractions derived from by-products of six fruits.

    PubMed

    Saikia, Sangeeta; Mahanta, Charu Lata

    2016-03-01

    A comparative study was done on the health promoting and functional properties of the fibers obtained as by-products from six fruits viz., pomace of carambola (Averrhoa carambola L.) and pineapple (Ananas comosus L. Merr), peels of watermelon (Citrullus lanatus), Burmese grape (Baccurea sapida Muell. Arg) and Khasi mandarin orange (Citrus reticulata Blanco), and blossom of seeded banana (Musa balbisiana, ABB). Highest yield of fiber was obtained from Burmese grape peel (BGPL, 79.94 ± 0.41 g/100 g) and seeded banana blossom (BB 77.18 ± 0.20 g/100 g). The total dietary fiber content (TDF) was highest in fiber fraction derived from pineapple pomace (PNPM, 79.76 ± 0.42 g/100 g) and BGPL (67.27 ± 0.39 g/100 g). All the samples contained insoluble dietary fiber as the major fiber fraction. The fiber samples showed good water holding, oil holding and swelling capacities. The fiber samples exhibited antioxidant activity. All the samples showed good results for glucose adsorption, amylase activity inhibition, glucose diffusion rate and glucose diffusion reduction rate index.

  11. Diagnostic accuracy of refractometry for assessing bovine colostrum quality: A systematic review and meta-analysis.

    PubMed

    Buczinski, S; Vandeweerd, J M

    2016-09-01

    Provision of good quality colostrum [i.e., immunoglobulin G (IgG) concentration ≥50g/L] is the first step toward ensuring proper passive transfer of immunity for young calves. Precise quantification of colostrum IgG levels cannot be easily performed on the farm. Assessment of the refractive index using a Brix scale with a refractometer has been described as being highly correlated with IgG concentration in colostrum. The aim of this study was to perform a systematic review of the diagnostic accuracy of Brix refractometry to diagnose good quality colostrum. From 101 references initially obtain ed, 11 were included in the systematic review meta-analysis representing 4,251 colostrum samples. The prevalence of good colostrum samples with IgG ≥50g/L varied from 67.3 to 92.3% (median 77.9%). Specific estimates of accuracy [sensitivity (Se) and specificity (Sp)] were obtained for different reported cut-points using a hierarchical summary receiver operating characteristic curve model. For the cut-point of 22% (n=8 studies), Se=80.2% (95% CI: 71.1-87.0%) and Sp=82.6% (71.4-90.0%). Decreasing the cut-point to 18% increased Se [96.1% (91.8-98.2%)] and decreased Sp [54.5% (26.9-79.6%)]. Modeling the effect of these Brix accuracy estimates using a stochastic simulation and Bayes theorem showed that a positive result with the 22% Brix cut-point can be used to diagnose good quality colostrum (posttest probability of a good colostrum: 94.3% (90.7-96.9%). The posttest probability of good colostrum with a Brix value <18% was only 22.7% (12.3-39.2%). Based on this study, the 2 cut-points could be alternatively used to select good quality colostrum (sample with Brix ≥22%) or to discard poor quality colostrum (sample with Brix <18%). When sample results are between these 2 values, colostrum supplementation should be considered. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  12. Selecting good regions to deblur via relative total variation

    NASA Astrophysics Data System (ADS)

    Li, Lerenhan; Yan, Hao; Fan, Zhihua; Zheng, Hanqing; Gao, Changxin; Sang, Nong

    2018-03-01

    Image deblurring is to estimate the blur kernel and to restore the latent image. It is usually divided into two stage, including kernel estimation and image restoration. In kernel estimation, selecting a good region that contains structure information is helpful to the accuracy of estimated kernel. Good region to deblur is usually expert-chosen or in a trial-anderror way. In this paper, we apply a metric named relative total variation (RTV) to discriminate the structure regions from smooth and texture. Given a blurry image, we first calculate the RTV of each pixel to determine whether it is the pixel in structure region, after which, we sample the image in an overlapping way. At last, the sampled region that contains the most structure pixels is the best region to deblur. Both qualitative and quantitative experiments show that our proposed method can help to estimate the kernel accurately.

  13. Rapid detection of food-borne Salmonella contamination using IMBs-qPCR method based on pagC gene.

    PubMed

    Wang, Jiashun; Li, Yi; Chen, Jia; Hua, Deping; Li, Yi; Deng, Hui; Li, Ying; Liang, Zhixuan; Huang, Jinhai

    Detection of Salmonella is very important to minimize the food safety risk. In this study, the recombinant PagC protein and PagC antibody were prepared and coupled with immunomagnetic beads (IMBs) to capture Salmonella cells from pork and milk samples. And then the SYBR Green qualitative PCR was developed to detect the pathogenic Salmonella. The results showed that the PagC polyclonal antiserum is of good specificity and the capture rate of 0.1mg IMBs for Salmonella tended to be stable at the range of 70-74% corresponding to the concentrations between 10 1 and 10 4 CFU/mL. The method developed demonstrated high specificity for the positive Salmonella samples when compared to non-specific DNA samples, such as Escherichia coli, Staphylococcus aureus, Yersinia enterocolitica, and Yersinia pseudotuberculosis. The limit of detection of this assay was 18CFU/mL. Detection and quantitative enumeration of Salmonella in samples of pork or milk shows good recoveries of 54.34% and 52.07%. In conclusion, the polyclonal antibody of recombinant PagC protein is effective to capture Salmonella from detected samples. The developed pagC antibody IMBs-qPCR method showed efficiency, sensitivity and specificity for 30 Salmonella detection, enabling detection within 10h, which is a promising rapid method to detect Salmonella in emergency. Copyright © 2017 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.

  14. An Independent Psychometric Evaluation of the PROMS Measure of Music Perception Skills.

    PubMed

    Kunert, Richard; Willems, Roel M; Hagoort, Peter

    2016-01-01

    The Profile of Music Perception Skills (PROMS) is a recently developed measure of perceptual music skills which has been shown to have promising psychometric properties. In this paper we extend the evaluation of its brief version to three kinds of validity using an individual difference approach. The brief PROMS displays good discriminant validity with working memory, given that it does not correlate with backward digit span (r = .04). Moreover, it shows promising criterion validity (association with musical training (r = .45), musicianship status (r = .48), and self-rated musical talent (r = .51)). Finally, its convergent validity, i.e. relation to an unrelated measure of music perception skills, was assessed by correlating the brief PROMS to harmonic closure judgment accuracy. Two independent samples point to good convergent validity of the brief PROMS (r = .36; r = .40). The same association is still significant in one of the samples when including self-reported music skill in a partial correlation (rpartial = .30; rpartial = .17). Overall, the results show that the brief version of the PROMS displays a very good pattern of construct validity. Especially its tuning subtest stands out as a valuable part for music skill evaluations in Western samples. We conclude by briefly discussing the choice faced by music cognition researchers between different musical aptitude measures of which the brief PROMS is a well evaluated example.

  15. An Independent Psychometric Evaluation of the PROMS Measure of Music Perception Skills

    PubMed Central

    Willems, Roel M.; Hagoort, Peter

    2016-01-01

    The Profile of Music Perception Skills (PROMS) is a recently developed measure of perceptual music skills which has been shown to have promising psychometric properties. In this paper we extend the evaluation of its brief version to three kinds of validity using an individual difference approach. The brief PROMS displays good discriminant validity with working memory, given that it does not correlate with backward digit span (r = .04). Moreover, it shows promising criterion validity (association with musical training (r = .45), musicianship status (r = .48), and self-rated musical talent (r = .51)). Finally, its convergent validity, i.e. relation to an unrelated measure of music perception skills, was assessed by correlating the brief PROMS to harmonic closure judgment accuracy. Two independent samples point to good convergent validity of the brief PROMS (r = .36; r = .40). The same association is still significant in one of the samples when including self-reported music skill in a partial correlation (rpartial = .30; rpartial = .17). Overall, the results show that the brief version of the PROMS displays a very good pattern of construct validity. Especially its tuning subtest stands out as a valuable part for music skill evaluations in Western samples. We conclude by briefly discussing the choice faced by music cognition researchers between different musical aptitude measures of which the brief PROMS is a well evaluated example. PMID:27398805

  16. Determination of glyoxal and methylglyoxal in environmental and biological matrices by stir bar sorptive extraction with in-situ derivatization.

    PubMed

    Neng, N R; Cordeiro, C A A; Freire, A P; Nogueira, J M F

    2007-10-26

    Stir bar sorptive extraction with in-situ derivatization using 2,3-diaminonaphthalene (DAN) followed by liquid desorption and high performance liquid chromatography with diode array detection (SBSE(DAN)in-situ-LD-HPLC-DAD) was developed for the determination of glyoxal (Gly) and methylglyoxal (MGly) in environmental and biological matrices. DAN proved very good specificity as in-situ derivatising agent for Gly and MGly in aqueous media, allowing the formation of adducts with remarkable sensitivity, selectivity and the absence of photodegradation. Assays performed on spiked (1.0 microg L(-1)) water samples, under convenient experimental conditions, yielded recoveries of 96.2+/-7.9% for Gly and 96.1+/-6.4% for MGly. The analytical performance showed good accuracy, suitable precision (<12.0%), low detection limits (15 ng L(-1) for Gly and 25 ng L(-1) for MGly adducts) and excellent linear dynamic ranges (r2>0.99) from 0.1 to 120.0 microg L(-1). By using the standard addition method, the application of the present method to tap and swimming-pool water, beer, yeast cells suspension and urine samples allowed very good performance at the trace level. The proposed methodology proved to be a feasible alternative for routine quality control analysis, showing to be easy to implement, reliable, sensitive and with a low sample volume requirement to monitor Gly and MGly in environmental and biological matrices.

  17. Simultaneous determination of 76 micropollutants in water samples by headspace solid phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    Martínez, C; Ramírez, N; Gómez, V; Pocurull, E; Borrull, F

    2013-11-15

    This study focuses on the development of an analytical method based on headspace solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of 76 micropollutants in water samples. The selected micropollutants include volatile organic compounds (VOCs) (e.g. chlorobenzenes, chloroalkanes), endocrine disrupting compounds (EDCs) (e.g. bisphenol A and tributyl phosphate), odour compounds (e.g. limonene, phenol), fragrance allergens (e.g. geraniol, eugenol) and some pesticides (e.g. heptachlor, terbutryn). The experimental conditions affecting their extraction, such as the type of fibre, temperature and time of extraction, sample volume and ionic strength of the samples were optimized using HS-SPME. The method showed good linear range, reproducibility between days, repeatability and low detection limits (at ng L(-1) levels). The validated method has been applied to determine the target organic micropollutants in aqueous samples from different experimental research units of surface water, sea water, waste water and those effluents of advance membrane treatments. The optimized method showed good performance in the different types of samples studied. The analysis revealed the presence of several micropollutants at concentrations between 20 and 5000 μg L(-1), such as ethylbenzene, o-xylene, p-isopropilbenzene, D-limonene, citral and isoeugenol, due to the fact that these species are commonly used in domestic and industrial applications. © 2013 Elsevier B.V. All rights reserved.

  18. Moral Absolutism, Self-Deception, and Moral Self-Concept in Men Who Commit Intimate Partner Violence: A Comparative Study With an Opposite Sample.

    PubMed

    Vecina, María L; Chacón, F; Pérez-Viejo, J M

    2016-01-01

    The objective of this study is to show compatible data with the idea that men who commit intimate partner violence are uninhibited about the moral consequences of their behaviors, probably because they feel certainty about the rightness of their moral values and they strongly deceive themselves to maintain a good moral self-concept, and thus a good level of well-being. To do that, we compare their scores with those obtained by an opposite sample regarding the use of violence, made up of professional male psychologists who work in the social field trying to teach others alternative strategies to violence. © The Author(s) 2015.

  19. Determination of sulfonamides in milk by capillary electrophoresis with PEG@MoS2 as a dispersive solid-phase extraction sorbent.

    PubMed

    An, Jianxin; Wang, Xuan; Ming, Meiting; Li, Jian; Ye, Nengsheng

    2018-05-01

    A synthetic polyethylene glycol-molybdenum disulfide (PEG@MoS 2 ) composite was prepared using a simple method, and the application of this material in dispersive solid-phase extraction (DSPE) was investigated for the enrichment of eight sulfonamides (SAs) in milk samples. The composite was characterized by energy dispersive spectroscopy, scanning electron microscopy, transmission electron microscopy, Fourier transform infrared spectroscopy and Brunauer-Emmett-Teller measurements. The results showed that the MoS 2 synthesized in the presence of PEG has the advantage of a larger surface area and that the adsorption effect of this MoS 2 was enhanced. After extraction, the eight SAs were separated by capillary zone electrophoresis with a good linear relationship ( R 2  > 0.9902) in the range of 0.3-30 µg ml -1 and good precision (between 0.32% and 9.83%). Additionally, good recoveries (between 60.52% and 110.91%) were obtained for the SAs in the milk samples. The developed PEG@MoS 2 -based DSPE method could be applied for the enrichment of SAs in real milk samples.

  20. [Validity and factorial invariance of the social ecological model in explaining fruit intake in Mexican schoolchildren].

    PubMed

    Ochoa-Meza, Gerardo; Sierra, Juan Carlos; Pérez-Rodrigo, Carmen; Aranceta Bartrina, Javier; Esparza-Del Villar, Óscar A

    2014-11-24

    To test the goodness of fit of a Motivation-Ability-Opportunity model (MAO-model) to evaluate the observed variance in Mexican schoolchildren's preferences to eat fruit and daily fruit intake; also to evaluate the factorial invariance across the gender and type of population (urban and semi-urban) in which children reside. A model with seven constructs was designed from a validated questionnaire to assess preferences, cognitive abilities, attitude, modelling, perceived barriers, accessibility at school, accessibility at home, and fruit intake frequency. The instrument was administered in a representative sample of 1434 schoolchildren of 5th and 6th grade of primary school in a cross-sectional and ex post fact study conducted in 2013 in six cities of the State of Chihuahua, Mexico. The goodness of fit indexes was adequate for the MAO-model and explained 39% of the variance in preference to eat fruit. The structure of the model showed very good factor structure stability and the dimensions of the scale were equivalent in the different samples analyzed. The model analyzed with structural equation modeling showed a parsimonious model that can be used to explain the variation in fruit intake of 10 to 12 year old Mexican schoolchildren. The structure of the model was strictly invariant in the different samples analyzed and showed evidence of cross validation. Finally, implications about the modification model to fit data from scholar settings and guidelines for future research are discussed. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  1. Assessment of Diesse Ves-matic automated system for measuring erythrocyte sedimentation rate.

    PubMed Central

    Caswell, M; Stuart, J

    1991-01-01

    Measurement of the erythrocyte sedimentation rate (ESR) using a closed tube system reduces the biohazard risk to laboratory staff. The Diesse Ves-matic system offers manual or vacuum collection of blood into plastic tubes, automated mixing of the sample, and automated reading of the end point after 20 minutes of sedimentation. This system was compared with the 1977 Westergren ESR method of the International Council for Standardization in Haematology (ICSH) and with the 1988 ICSH undiluted ESR method. Manually collected Ves-matic samples showed good agreement with ICSH values, although there was a tendency to false low results at low ESR values which may represent dilution of plasma protein with excess citrate. Vacuum collected Ves-matic samples also showed good agreement with ICSH values, although there was a tendency to false high results which may reflect a change in the blood: citrate ratio caused by loss of anticoagulant diluent or vacuum from plastic tubes during storage. The Diesse Ves-matic system incorporates several improvements over previous technology and offers a safer, quicker, and more standardised ESR. PMID:1752986

  2. Continuum Excitation and Pseudospin Wave in Quantum Spin-Liquid and Quadrupole Ordered States of Tb2+xTi2-xO7+y

    NASA Astrophysics Data System (ADS)

    Kadowaki, Hiroaki; Wakita, Mika; Fåk, Björn; Ollivier, Jacques; Ohira-Kawamura, Seiko; Nakajima, Kenji; Takatsu, Hiroshi; Tamai, Mototake

    2018-06-01

    The ground states of the frustrated pyrochlore oxide Tb2+xTi2-xO7+y have been studied by inelastic neutron scattering experiments. Three single-crystal samples are investigated; one shows no phase transition (x = -0.007 < xc ˜ -0.0025), being a putative quantum spin-liquid (QSL), and the other two (x = 0.000,0.003) show electric quadrupole ordering (QO) below Tc ˜ 0.5 K. The QSL sample shows continuum excitation spectra with an energy scale 0.1 meV as well as energy-resolution-limited (nominally) elastic scattering. As x is increased, pseudospin wave of the QO state emerges from this continuum excitation, which agrees with that of powder samples and consequently verifies good x control for the present single crystal samples.

  3. Potential sources of microbial contamination in unpasteurized apple cider.

    PubMed

    Garcia, Luis; Henderson, John; Fabri, Martha; Oke, Moustapha

    2006-01-01

    A study was conducted to identify possible sources of microbial contamination and to assess the effect of good cleaning and sanitation practices on the microbial quality and safety of unpasteurized apple cider. Raw unwashed apples, washed apples, cleaning water, fresh cider, and finished cider samples were collected from five Ontario producers over 4 months and microbiologically tested. Total coliforms were found in 31, 71 and 38% of the unwashed apple, water, and washed apple samples, respectively. Escherichia coli was found in 40% of the water samples from one producer alone. The washing step was identified as a potential source of contamination, possibly due to water in the dump tanks seldom being refreshed, and because scrubbers, spray nozzles, and conveyors were not properly cleaned and sanitized. Higher total coliform counts (P < 0.0001) and prevalence (P < 0.0001) in fresh cider compared with those in unwashed apples and washed apples indicated considerable microbial buildup along the process, possibly explained by the lack of appropriate equipment sanitation procedures. Results showed that producers who had better sanitary practices in place had lower (P < 0.001) total coliform prevalence than the rest of the producers. Overall results show that good sanitation procedures are associated with improved microbial quality of fresh cider in terms of total coliforms and that operators who pasteurize and/or UV treat their product should still be required to have a sound good manufacturing practices program in place to prevent recontamination. Cryptosporidium parvum, an important pathogen for this industry, was found in different sample types, including washed apples, water, and fresh and finished cider.

  4. Variation in the Helical Structure of Native Collagen

    DTIC Science & Technology

    2014-02-24

    unsampled molecular transform of the sample (non-crystalline diffraction arising from the helical symmetry), these patterns also contain Bragg peaks...tissues may be treated as analogous to that from a single macromolecular crystal. Except that it arises from many fibrils within the sample , giving rise...density maps, constructed from experimentally determined phases and observed amplitudes, showed good agreement. The observed diffraction and the simulated

  5. Miniaturized flow system based on enzyme modified PMMA microreactor for amperometric determination of glucose.

    PubMed

    Cerdeira Ferreira, Luís Marcos; da Costa, Eric Tavares; do Lago, Claudimir Lucio; Angnes, Lúcio

    2013-09-15

    This paper describes the development of a microfluidic system having as main component an enzymatic reactor constituted by a microchannel assembled in poly(methyl methacrylate) (PMMA) substrate connected to an amperometric detector. A CO2 laser engraving machine was used to make the channels, which in sequence were thermally sealed. The internal surfaces of the microchannels were chemically modified with polyethyleneimine (PEI), which showed good effectiveness for the immobilization of the glucose oxidase enzyme using glutaraldehyde as crosslinking agent, producing a very effective microreactor for the detection of glucose. The hydrogen peroxide generated by the enzymatic reaction was detected in an electrochemical flow cell localized outside of the reactor using a platinum disk as the working electrode. The proposed system was applied to the differential amperometric determination of glucose content in soft drinks showing good repeatability (DPR=1.72%, n=50), low detection limit (1.40×10(-6)molL(-1)), high sampling frequency (calculated as 345 samples h(-1)), and relatively good stability for long-term use. The results were in close agreement with those obtained by the classical spectrophotometric method utilized to quantify glucose in biological fluids. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Validation to Portuguese of the Scale of Student Satisfaction and Self-Confidence in Learning.

    PubMed

    Almeida, Rodrigo Guimarães dos Santos; Mazzo, Alessandra; Martins, José Carlos Amado; Baptista, Rui Carlos Negrão; Girão, Fernanda Berchelli; Mendes, Isabel Amélia Costa

    2015-01-01

    Translate and validate to Portuguese the Scale of Student Satisfaction and Self-Confidence in Learning. Methodological translation and validation study of a research tool. After following all steps of the translation process, for the validation process, the event III Workshop Brazil - Portugal: Care Delivery to Critical Patients was created, promoted by one Brazilian and another Portuguese teaching institution. 103 nurses participated. As to the validity and reliability of the scale, the correlation pattern between the variables, the sampling adequacy test (Kaiser-Meyer-Olkin) and the sphericity test (Bartlett) showed good results. In the exploratory factorial analysis (Varimax), item 9 behaved better in factor 1 (Satisfaction) than in factor 2 (Self-confidence in learning). The internal consistency (Cronbach's alpha) showed coefficients of 0.86 in factor 1 with six items and 0.77 for factor 2 with 07 items. In Portuguese this tool was called: Escala de Satisfação de Estudantes e Autoconfiança na Aprendizagem. The results found good psychometric properties and a good potential use. The sampling size and specificity are limitations of this study, but future studies will contribute to consolidate the validity of the scale and strengthen its potential use.

  7. Validation of the Italian version of the Clinical Outcomes in Routine Evaluation Outcome Measure (CORE-OM).

    PubMed

    Palmieri, Gaspare; Evans, Chris; Hansen, Vidje; Brancaleoni, Greta; Ferrari, Silvia; Porcelli, Piero; Reitano, Francesco; Rigatelli, Marco

    2009-01-01

    The Clinical Outcomes in Routine Evaluation--Outcome Measure (CORE-OM) was translated into Italian and tested in non-clinical (n = 263) and clinical (n = 647) samples. The translation showed good acceptability, internal consistency and convergent validity in both samples. There were large and statistically significant differences between clinical and non-clinical datasets on all scores. The reliable change criteria were similar to those for the UK referential data. Some of the clinically significant change criteria, particularly for the men, were moderately different from the UK cutting points. The Italian version of the CORE-OM showed respectable psychometric parameters. However, it seemed plausible that non-clinical and clinical distributions of self-report scores on psychopathology and functioning measures may differ by language and culture. *A good quality Italian translation of the CORE-OM, and hence the GP-CORE, CORE-10 and CORE-5 measures also, is now available for use by practitioners and anyone surveying or exploring general psychological state. The measures can be obtained from CORE-IMS or yourself and practitioners are encouraged to share anonymised data so that good clinical and non-clinical referential databases can be established for Italy.

  8. Online in-tube microextractor coupled with UV-Vis spectrophotometer for bisphenol A detection.

    PubMed

    Poorahong, Sujittra; Thammakhet, Chongdee; Thavarungkul, Panote; Kanatharana, Proespichaya

    2013-01-01

    A simple and high extraction efficiency online in-tube microextractor (ITME) was developed for bisphenol A (BPA) detection in water samples. The ITME was fabricated by a stepwise electrodeposition of polyaniline, polyethylene glycol and polydimethylsiloxane composite (CPANI) inside a silico-steel tube. The obtained ITME coupled with UV-Vis detection at 278 nm was investigated. By this method, the extraction and pre-concentration of BPA in water were carried out in a single step. Under optimum conditions, the system provided a linear dynamic range of 0.1 to 100 μM with a limit of detection of 20 nM (S/N ≥3). A single in-tube microextractor had a good stability of more than 60 consecutive injections for 10.0 μM BPA with a relative standard deviation of less than 4%. Moreover, a good tube-to-tube reproducibility and precision were obtained. The system was applied to detect BPA in water samples from six brands of baby bottles and the results showed good agreement with those obtained from the conventional GC-MS method. Acceptable percentage recoveries from the spiked water samples were obtained, ranging from 83-102% for this new method compared with 73-107% for the GC-MS standard method. This new in-tube CPANI microextractor provided an excellent extraction efficiency and a good reproducibility. In addition, it can also be easily applied for the analysis of other polar organic compounds contaminated in water sample.

  9. The relationship between hardness to the tensile properties of kenaf/ unsaturated polyester composite

    NASA Astrophysics Data System (ADS)

    Ghaztar, Muhammad Mustakim Mohd; Romli, Ahmad Zafir; Ibrahim, Nik Noor Idayu Nik

    2017-12-01

    The level of fibre-matrix interaction and consolidation are essential aspects to determine the composite deformation but, less attention is given to the effect of small fibre weight increment (5 wt%), chemical treatment coalition (NaOH/ silane), fibre's length and aspect ratio to the physical and mechanical properties of the composite. Hence, this paper studies the correlation between these parameters towards hardness and tensile properties of Kenaf fibre and unsaturated polyester (UP) matrix. The study was carried out by fabricating the sample into two (2) types of fibre categories and fibre loadings and tested to determine its properties. The results showed that the hardness and tensile stress were significantly influenced by the fibre loading and dispersion of the fabricated samples. At low filler loading, the treated samples for both fibre sizes showed lower hardness property compared to the untreated samples. The chemical treatment coalition might diffuse out the pectin and hemicellulose which affect the ability of the fibre to absorb the force applied by the hardness indenter. Good fibre dispersion observed for the treated samples also resulted in the fibre-dominating composite system where the fibres were efficiently absorbed and distributed the indentation force. However, chemical treatments and good fibre dispersion contributed to the higher tensile stress of the treated fibre samples especially for smaller fibre length and aspect ratio compared to the untreated samples. At high fibre loading, treated fibre samples showed higher hardness property compared to the untreated samples since the treatment resulted in better fibre wetting by the matrix and the formation of pack structure. However, high fibre loading caused the mutual abrasion among the fibre which led to the lower tensile stress compared to the low fibre loading samples. In conclusion, by understanding the factors that influenced the reinforcing mechanism of the composite, the inconsistency of natural based composite strength can be resolved.

  10. The development of the learning video for the flipped classroom model on student of open university on human skeletal system and muscles

    NASA Astrophysics Data System (ADS)

    Andrini, V. S.

    2018-05-01

    The objectives of the research are to develop the learning video for the flipped classroom model for Open University’s student and to know the effectiveness of the video. The development of the video used Research and Development ADDIE design (Analyses, Design, Development, Implementation, Evaluation). The sampling used purposive sampling was 28 students in Open University of Nganjuk. The techniques of data collection were the observation data to know the problems of the students, and learning facilities, the test (pre-test and post-test) to know a knowledge aspect, a questionnaire to know advisability of video learning, a structured interview to confirm their answer. The result of the expert of matter and media showed that the average product score was 3.75 of 4 or very good, the small-scale test showed that the average score was 3.60 of 4 and the large-scale test showed that the average score was 3.80 of 4, it had a very good category. The t-test with paired sample test showed that sig. (2-tailed) < 0.05. The N-gain score of pre and post test was 0.55, it had the medium category. It can be concluded that the development of the learning video for flipped classroom was effective to be implemented.

  11. Properties of lithium aluminate for application as an OSL dosimeter

    NASA Astrophysics Data System (ADS)

    Twardak, A.; Bilski, P.; Marczewska, B.; Lee, J. I.; Kim, J. L.; Gieszczyk, W.; Mrozik, A.; Sądel, M.; Wróbel, D.

    2014-11-01

    Several samples of undoped and carbon or copper doped lithium aluminate (LiAlO2) were prepared in an attempt to achieve a material, which can be applicable in optically stimulated luminescence (OSL) dosimetry. All investigated samples are highly sensitive to ionizing radiation and show good reproducibility. The undoped and copper doped samples exhibit sensitivity several times higher than that of Al2O3:C, while sensitivity of the carbon doped samples is lower. The studied samples exhibit significant fading, but dynamics of signal loss is different for differently doped samples, what indicates a possibility of improving this characteristic by optimizing dopant composition.

  12. Psychometric Properties of the Family Inventory of Resources for Management in a Sample of Iranian Family Caregivers of Cancer Patients

    PubMed Central

    Mirsoleymani, Seyed Reza; Matbouei, Mahsa; Nasiri, Malihe; Vasli, Parvaneh

    2016-01-01

    Objective. The aim of this study was to investigate the psychometric properties of the Family Inventory of Resources for Management (FIRM) in a sample of family caregivers of cancer patients. Methods. In this methodological study, construct validity of the FIRM was evaluated by known groups and convergent validity in a convenience sample of family caregivers of cancer patients (n = 104) referred to the outpatient oncology wards of five educational hospitals in Tehran from January to April 2016. Reliability was determined by assessing the internal consistency and stability of the instrument. Results. The known-groups findings showed that there is a significant difference between the scores of the FIRM in family caregivers with different levels of caregiver burden (p < 0.001). Also, the results of convergent validity showed that there is a moderate negative correlation (r = −0.50; p < 0.001) between the total scores of the FIRM and the scores of the caregiver burden inventory (CBI). The FIRM showed a good internal consistency (α = 0.85) and a good stability of the test-retest reliability result. Conclusions. There is a sound psychometric basis for the use of the Persian translation of the FIRM for family studies in the Iranian population. PMID:28127470

  13. Establishing the validity and reliability of the Project Talent Personality Inventory

    PubMed Central

    Pozzebon, Julie; Damian, Rodica I.; Hill, Patrick L.; Lin, Yuchen; Lapham, Susan; Roberts, Brent W.

    2013-01-01

    Project Talent is a national longitudinal study that started in 1960. The original sample included over 440,000 students, which amounted to a 5% representative sample of high school students across the United States. Previous research has not yet established the validity and reliability of the personality measure used in this study, that is, the Project Talent Personality Inventory (PTPI). Given the potential interest and use of the PTPI in forthcoming research, the goals of the present paper were to establish (a) the construct and predictive validity and (b) the internal consistency and test-retest reliability of the PTPI. This information will be valuable to researchers who might be interested in using the PTPI to predict life course outcomes, such as mortality, occupational success, relationship success, and health. Study 1 found that the 10 sub-scales of the PTPI showed good internal consistency reliability, as well as good construct and predictive validity. With the use of several modern personality measures, we showed how the 10 PTPI scales can be mapped onto the Big Five personality traits, and we examined their relations with health, well-being, and life satisfaction outcomes. Study 2 found that the 10 PTPI scales showed good test-retest reliability. Together, these findings allow researchers to better understand and use the PTPI scales, as they are available in Project Talent. PMID:24399984

  14. Zinc oxide crystal whiskers as a novel sorbent for solid-phase extraction of flavonoids.

    PubMed

    Wang, Licheng; Shangguan, Yangnan; Hou, Xiudan; Jia, Yong; Liu, Shujuan; Sun, Yingxin; Guo, Yong

    2017-08-15

    As a novel solid-phase extraction material, zinc oxide crystal whiskers were used to extract flavonoid compounds and showed good extraction abilities. X-ray diffraction, scanning electron microscopy with energy dispersive X-ray spectroscopy and surface area/pore volume characterized the sorbent. The zinc oxide was packed into a solid-phase extraction micro-column and its extraction ability was evaluated by four model flavonoid compounds. The sample loading and elution parameters were optimized and the zinc oxide based analytical method for flavonoids was established. It showed that the method has wide linearities from 1 to 150μg/L and low limits of detection at 0.25μg/L. The relative standard deviations of a single column repeatability and column to column reproducibility were less than 6.8% and 10.6%. Several real samples were analyzed by the established method and satisfactory results were obtained. The interactions between flavonoids and zinc oxide were calculated and proved to be from the Van der Waals' forces between the 4p and 5d orbitals from zinc atom and the neighboring π orbitals from flavonoid phenyl groups. Moreover, the zinc oxide crystal whiskers showed good stability and could be reused more than 50 times under the operation conditions. This work proves that the zinc oxide crystal whiskers are a good candidate for flavonoids enrichment. Copyright © 2017. Published by Elsevier B.V.

  15. Irrigation water quality and the benefits of implementing good agricultural practices during tomato (Lycopersicum esculentum) production.

    PubMed

    Estrada-Acosta, M; Jiménez, M; Chaidez, C; León-Félix, J; Castro-Del Campo, N

    2014-07-01

    The implementation of good agricultural practices (GAP) from irrigation water to the tomato packaging process enhances the safety of fresh produce and its value throughout the food chain. The aim of the present study was to show that fresh produce farms that apply and enforce GAP could reduce the presence of Salmonella in finished produce. Samples were collected biweekly from six packing houses from the central region of Sinaloa, México, for the isolation of Salmonella spp by the ISO 6579:2002 method, and the isolated strains were serotyped and genotyped by the Kauffmman-White scheme and pulsed field gel electrophoresis (PFGE), respectively. Salmonella strains were detected in 13 (36.1 %) irrigation water samples, while only two tomato samples were positive (5.5 %). Eight different serotypes were identified in irrigation water, and Salmonella Oranienburg (34 %) was the most prevalent; however, only Salmonella Agona and Salmonella Weltevreden were present on tomatoes. Salmonella Oranienburg was the most widely dispersed and variable serotype, with 10 different PFGE profiles. Salmonella Weltevreden was isolated from both types of samples, albeit with distinct genetic profiles, implying that the sources of contamination differ. These results confirm the utility of implementing good agricultural practices to reduce Salmonella contamination in irrigation water and the packaging process.

  16. Asian Dust Storm Events of 2001 and Associated Pollution Observed in New England by the AIRMAP Monitoring Network

    NASA Astrophysics Data System (ADS)

    Debell, L. J.; Vozzella, M. E.; Talbot, R. W.; Dibb, J. E.

    2002-12-01

    The Atmospheric Investigation, Regional Modeling, Analysis and Prediction (AIRMAP) program is operating 4 monitoring sites in New Hampshire, located at Fort Constitution (FC)(43.07oN, 70.71oW, 5m elevation), Thompson Farm (TF) (43.11oN, 70.95oW, 21m elevation), Castle Springs (CS) (43.75oN,71.35oW, 406m elevation) and Mount Washington (MW)(44.267oN, 71.30oW, 1909m elevation). Three chemically distinct, statistically extreme, regional scale dust aerosol events were observed at all four AIRMAP monitoring stations in NH between 4/18/01 and 5/13/01 (UTC). All three events, at all four sites, had days where the 24 hr bulk aerosol samples had Ca2+ concentrations that exceeded at least the 95th percentile of the site-specific, multi-year datasets. NO3- and SO42- were also enhanced above typical levels, ranging from above the 75th to above the 99th percentile. During all three events, mixing ratios of the gas phase pollutants O3 and CO were compared to mixing ratios on either side of the events. During event 1,enhancements above background levels were approximately 130 ppbv for CO and 30 ppbv for O3, very similar to the CO values in apparent Asian dust plumes sampled over Colorado at 6-7 km by aircraft measurements (http://www.cmdl.noaa.gov/info/asiandust.html); enhancements during events 2 and 3 were similar to event 1. The maximum elemental carbon value ever observed at TF, 0.97 μg/m3, occurred during the peak day of event 1. Elemental carbon was not substantially elevated during event 2 and no data were collected during event 3. Elemental ratios, determined by PIXE, on filters from events 1 and 3 were compared pairwise to each other and to published samples attributed to Asian dust storms. The AIRMAP samples collected on the same date at different sites showed good statistical agreement whereas samples collected at the same site on different dates show only moderate correlation. Of 17 published samples of Asian dust storm aerosol, collected well outside of the major desert and loess source regions, 15 showed good statistical agreement with at least 2 of our samples. In addition, at least 2 of our samples have good agreement with 1 published aerosol sample collected in the Gobi desert and for 1 published soil sample collected in the Takla Makan desert; indicating that the Asian dust storms are a possible source for our events. We also compared elemental ratios in our dust impacted samples to the IMPROVE dataset from Acadia, ME. Acadia was chosen for the longevity and completeness of its record and downwind location from the AIRMAP stations. Out of the over 1400 IMPROVE aerosol samples collected between 1988 and 2001, 476 have both Al, Fe and Ca above detection limit, and 120 show good agreement with at least 1 AIRMAP sample. The 120 samples selected above occurred primarily in spring: 52 samples from 3/1-5/15, 37 samples from 2/15-3/1 or 5/15-6/31. All three events are clearly discernible in the Acadia dataset both in timing and chemical similarity with the AIRMAP samples. A U.S. source cannot be ruled out chemically, but there are no reports in the National Climatic Data Centers Storm Publication that indicated large-scale dust storms in the period 4/10/01-5/10/01. TOMS images and the NRL-NAAPS model results also support an Asian source for the 3 events.

  17. Detection of Irradiation Treatment of Foods Using DNA `Comet Assay'

    NASA Astrophysics Data System (ADS)

    Khan, Hasan M.; Delincée, Henry

    1998-06-01

    Microgel electrophoresis of single cells (DNA comet assay) has been investigated to detect irradiation treatment of some food samples. These samples of fresh and frozen rainbow trout, red lentil, gram and sliced almonds were irradiated to 1 or 2 kGy using 10 MeV electron beam from a linear accelerator. Rainbow trout samples yielded good results with samples irradiated to 1 or 2 kGy showing fragmentation of DNA and, therefore, longer comets with no intact cells. Unirradiated samples showed shorter comets with a significant number of intact cells. For rainbow trout stored in a freezer for 11 days the irradiated samples can still be discerned by electrophoresis from unirradiated samples, however, the unirradiated trouts also showed some longer comets besides some intact cells. Radiation treatment of red lentils can also be detected by this method, i.e. no intact cells in 1 or 2 kGy irradiated samples and shorter comets and some intact cells in unirradiated samples. However, the results for gram and sliced almond samples were not satisfactory since some intact DNA cells were observed in irradiated samples as well. Probably, incomplete lysis has led to these deviating results.

  18. Surface crystallization behavior and physical properties of (GeTe4)85(AgI)15 chalcogenide glass

    NASA Astrophysics Data System (ADS)

    Zhu, Erwei; Wu, Bo; Zhao, Xuhao; Wang, Jingsong; Lin, Changgui; Wang, Xunsi; Li, Xing; Tian, Peijing

    2017-11-01

    Glass-ceramics embedded Te and α-GeTe particles were fabricated from (GeTe4)85(AgI)15 chalcohalide glass using an appropriate heat-treatment at fairly low temperatures ranging from 160 to 190 °C for different times. The crystallization behavior and physical properties of the obtained samples were studied in detail. The glass transition temperature of crystallized samples increases with the elongation of crystallization times. And the results of mechanical properties show that, compared with the base glass, the crystallized samples present improved thermal shock resistance and fracture toughness, and meanwhile still remain its good IR transmittance. This study could provide an initial observation of crystallization in telluride glasses, and be of good guidance to fabricate novel telluride glass-ceramics that operating in far-IR spectral region ranging from 2.5 μm to 25 μm.

  19. Rapid sucrose monitoring in green coffee samples using multienzymatic biosensor.

    PubMed

    Stredansky, Miroslav; Redivo, Luca; Magdolen, Peter; Stredansky, Adam; Navarini, Luciano

    2018-07-15

    Amperometric biosensor utilizing FAD-dependent glucose dehydrogenase (FAD-GDH) for a specific sucrose monitoring in green coffee is described. FAD-GDH was co-immobilized with invertase and mutarotase on a thin-layer gold planar electrode using chitosan. The biosensor showed a wide linearity (from 10 to 1200 μM), low detection limit (8.4 μM), fast response time (50 s), and appeared to be O2 independent. In addition the biosensors exhibited a good operational (3 days) and storage (1 year) stability. Finally, the results achieved from the biosensor measurements of sucrose in 17 samples of green coffee (Coffea arabica, C. canephora and C. liberica) were compared with those obtained by the standard HPLC method. The good correlation among results of real samples, satisfactory analytical performance and simple use of the presented biosensor make it suitable for application in coffee industry. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. [Ichthyoplankton from the pier area in Limón, Costa Rica].

    PubMed

    Dominici-Arosemena, A; Brugnoli-Olivera, E; Solano-Ulate, S; Molina-Ureña, H; Ramírez Coghi, A R

    2000-01-01

    Four sampling stations were set 200-500 m off Limon Port, Costa Rica, at an average depth of 20 m. From October 1996 to May 1997 horizontal subsuperficial trawls were done for 12 minutes at a speed of about 2 Km/h, with a 1,000 microns plancton net. A total of 28 samples were processed and 104 physical-chemistry parameter measurements were taken. Average salinity was 30.1 +/- 3.7 and dissolved oxygen 6.9 +/- 0.6 mg l-1 reflecting good aeration throughout the sampling period. This suggests good mixture and a highly dynamic hydrography. Temperature showed no drastic variations (28.0 +/- 1.7 degrees C), possibly because of the constant mixing with shallow water. The highest larval counts were for November and early January and include families common to reefs and estuaries (Balistidae, Lutjanidae) and to coastal areas (Centropomidae, Gerreidae, Haemulidae, Carangidae, Engraulidae, Hemiramphidae, and representative Pleuronectiformes) existing in a common area.

  1. Fate of iprovalicarb, indoxacarb, and boscalid residues in grapes and wine by GC-ITMS analysis.

    PubMed

    Angioni, Alberto; Dedola, Fabrizio; Garau, Vincenzo Luigi; Schirra, Mario; Caboni, Pierluigi

    2011-06-22

    The behavior in field and the transfer from grapes to wine during winemaking of iprovalicarb, indoxacarb, and boscalid was studied. The residue levels found in grapes were far below the MRLs set for grapes in EU, accounting at harvest time 0.81, 0.43, and 4.23 mg/kg for iprovalicarb, indoxacarb, and boscalid, respectively. The residue levels in the samples treated with boscalid may have residual problems (due to an accumulation effect) if repeated field treatments will be performed. Winemaking experiments showed a complete transfer of all pesticide from grapes to the must, while in wine the residues were low or negligible due to the adsorbing effect of lees and pomace. The clarification experiments showed a good removal of pesticide residues from the wine media, for all pesticides. The GC-ITMS method showed good performance with adequate recoveries ranging from 75 to 115%, and good method limits of quantitation (LOQs) and of determination (LODs) far below MRLs.

  2. Cadmium Isotope Variations in Bulk Chondrites: The Effect of Thermal Neutron Capture

    NASA Astrophysics Data System (ADS)

    Toth, E. R.; Schönbächler, M.; Friebel, M.; Fehr, M. A.

    2017-07-01

    Cadmium isotope data will be presented for bulk carbonaceous and enstatite chondrites, and acid leachates of Jbilet Winselwan (CM). Results of bulk samples show Cd isotope variations that are in good agreement with models of thermal neutron capture.

  3. Emittance measurements of Space Shuttle orbiter reinforced carbon-carbon

    NASA Technical Reports Server (NTRS)

    Caram, Jose M.; Bouslog, Stanley A.; Cunnington, George R., Jr.

    1992-01-01

    The spectral and total normal emittance of the Reinforced Carbon-Carbon (RCC) used on Space Shuttle nose cap and wing leading edges has been measured at room temperature and at surface temperatures of 1200 to 2100 K. These measurements were made on virgin and two flown RCC samples. Room temperature directional emittance data were also obtained and were used to determine the total hemispherical emittance of RCC as a function of temperature. Results of the total normal emittance for the virgin samples showed good agreement with the current RCC emittance design curve; however, the data from the flown samples showed an increase in the emittance at high temperature possibly due to exposure from flight environments.

  4. Optimization of microwave digestion for mercury determination in marine biological samples by cold vapour atomic absorption spectrometry.

    PubMed

    Cardellicchio, Nicola; Di Leo, Antonella; Giandomenico, Santina; Santoro, Stefania

    2006-01-01

    Optimization of acid digestion method for mercury determination in marine biological samples (dolphin liver, fish and mussel tissues) using a closed vessel microwave sample preparation is presented. Five digestion procedures with different acid mixtures were investigated: the best results were obtained when the microwave-assisted digestion was based on sample dissolution with HNO3-H2SO4-K2Cr2O7 mixture. A comparison between microwave digestion and conventional reflux digestion shows there are considerable losses of mercury in the open digestion system. The microwave digestion method has been tested satisfactorily using two certified reference materials. Analytical results show a good agreement with certified values. The microwave digestion proved to be a reliable and rapid method for decomposition of biological samples in mercury determination.

  5. Support vector machine incremental learning triggered by wrongly predicted samples

    NASA Astrophysics Data System (ADS)

    Tang, Ting-long; Guan, Qiu; Wu, Yi-rong

    2018-05-01

    According to the classic Karush-Kuhn-Tucker (KKT) theorem, at every step of incremental support vector machine (SVM) learning, the newly adding sample which violates the KKT conditions will be a new support vector (SV) and migrate the old samples between SV set and non-support vector (NSV) set, and at the same time the learning model should be updated based on the SVs. However, it is not exactly clear at this moment that which of the old samples would change between SVs and NSVs. Additionally, the learning model will be unnecessarily updated, which will not greatly increase its accuracy but decrease the training speed. Therefore, how to choose the new SVs from old sets during the incremental stages and when to process incremental steps will greatly influence the accuracy and efficiency of incremental SVM learning. In this work, a new algorithm is proposed to select candidate SVs and use the wrongly predicted sample to trigger the incremental processing simultaneously. Experimental results show that the proposed algorithm can achieve good performance with high efficiency, high speed and good accuracy.

  6. Predicting capillarity of mudrocks for geological storage of CO2

    NASA Astrophysics Data System (ADS)

    Busch, Andreas; Amann-Hildenbrand, Alexandra

    2013-04-01

    Various rock types were investigated, with the main focus on the determination and prediction of the capillary breakthrough and snap-off pressure in mudrocks (e.g. shales, siltstones, mudstones). Knowledge about these two critical pressures is important for the prediction of the capillary sealing capacity of CO2 storage sites. Capillary pressure experiments, when performed on low-permeable core plugs, are difficult and time consuming. Laboratory measurements on core plugs under in-situ conditions are mostly performed using nitrogen, but also with methane and carbon dioxide. Therefore, mercury porosimetry measurements (MIP) are preferably used in the industry to determine an equivalent value for the capillary breakthrough pressure. These measurements have the advantage to be quick and cheap and only require cuttings or trim samples. When evaluating the database in detail we find that (1) MIP data plot well with the drainage breakthrough pressures determined on sample plugs, while the conversion of the system Hg/air to CO2/brine using interfacial and wettability data does not provide a uniform match, potentially caused by non fully water-wet conditions; (2) brine permeability versus capillary breakthrough pressure determined on sample plugs shows a good match and could provide a first estimate of Pc-values since permeability is easier to determine than capillary breakthrough pressures. For imbibition snap-off pressures a good correlation was found for CH4 measured on sample plugs only; (3) porosity shows a fairly good correlation with permeability for sandstone only, and with plug-derived capillary breakthrough pressures for sandstones, carbonates and evaporates. No such correlations exist for mudrocks; (4) air and brine-derived permeabilities show an excellent correlation and (5) from the data used we do not infer any direct correlations between specific surface area (SSA), mineralogy or organic carbon content with permeability or capillary pressure however were able to predict permeabilities using a more sophisticated model that relies on several of these parameters.

  7. Prefrontal electroencephalographic activity during the working memory processes involved in a sexually motivated task in male rats.

    PubMed

    Hernández-González, Marisela; Almanza-Sepúlveda, Mayra Linné; Olvera-Cortés, María Esther; Gutiérrez-Guzmán, Blanca Erika; Guevara, Miguel Angel

    2012-08-01

    The prefrontal cortex is involved in working memory functions, and several studies using food or drink as rewards have demonstrated that the rat is capable of performing tasks that involve working memory. Sexual activity is another highly-rewarding, motivated behaviour that has proven to be an efficient incentive in classical operant tasks. The objective of this study was to determine whether the functional activity of the medial prefrontal cortex (mPFC) changes in relation to the working memory processes involved in a sexually motivated task performed in male rats. Thus, male Wistar rats implanted in the mPFC were subjected to a nonmatching-to-sample task in a T-maze using sexual interaction as a reinforcer during a 4-day training period. On the basis of their performance during training, the rats were classified as 'good-learners' or 'bad-learners'. Only the good-learner rats showed an increase in the absolute power of the 8-13 Hz band during both the sample and test runs; a finding that could be related to learning of the working memory elements entailed in the task. During the maintenance phase only (i.e., once the rule had been learned well), the good-learner rats also showed an increased correlation of the 8-13 Hz band during the sample run, indicating that a high degree of coupling between the prefrontal cortices is necessary for the processing required to allow the rats to make correct decisions in the maintenance phase. Taken together, these data show that mPFC activity changes in relation to the working memory processes involved in a sexually motivated task in male rats.

  8. Separation of Be and Al for AMS using single-step column chromatography

    NASA Astrophysics Data System (ADS)

    Binnie, Steven A.; Dunai, Tibor J.; Voronina, Elena; Goral, Tomasz; Heinze, Stefan; Dewald, Alfred

    2015-10-01

    With the aim of simplifying AMS target preparation procedures for TCN measurements we tested a new extraction chromatography approach which couples an anion exchange resin (WBEC) to a chelating resin (Beryllium resin) to separate Be and Al from dissolved quartz samples. Results show that WBEC-Beryllium resin stacks can be used to provide high purity Be and Al separations using a combination of hydrochloric/oxalic and nitric acid elutions. 10Be and 26Al concentrations from quartz samples prepared using more standard procedures are compared with results from replicate samples prepared using the coupled WBEC-Beryllium resin approach and show good agreement. The new column procedure is performed in a single step, reducing sample preparation times relative to more traditional methods of TCN target production.

  9. Fluorescent trimethyl-substituted naphthyridine as a label-free signal reporter for one-step and highly sensitive fluorescent detection of DNA in serum samples.

    PubMed

    Wang, Jiamian; Wang, Xiuyun; Wu, Shuo; Che, Ruping; Luo, Pinchen; Meng, Changgong

    2017-01-15

    A facile label-free sensing method is developed for the one-step and highly sensitive fluorescent detection of DNA, which couples the specific C-C mismatch bonding and fluorescent quenching property of a trimethyl-substituted naphthyridine dye (ATMND) with the exonuclease III (Exo III) assisted cascade target recycling amplification strategy. In the absence of target DNA, the DNA hairpin probe with a C-C mismatch in the stem and more than 4 bases overhung at the 3' terminus could entrap and quench the fluorescence of ATMND and resist the digestion of Exo III, thus showing a low fluorescence background. In the presence of the target, however, the hybridization event between the two protruding segments and the target triggers the digestion reaction of Exo III, recycles the initial target, and simultaneously releases both the secondary target analogue and the ATMND caged in the stem. The released initial and secondary targets take part in another cycle of digestion, thus leading to the release of a huge amount of free ATMND for signal transducing. Based on the fluorescence recovery, the as-proposed label-free fluorescent sensing strategy shows very good analytical performances towards DNA detection, such as a wide linear range from 10pM to 1μM, a low limit of detection of 6pM, good selectivity, and a facile one-step operation at room temperature. Practical sample analysis in serum samples indicates the method has good precision and accuracy, which may thus have application potentials for point-of-care screening of DNA in complex clinical and environmental samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Solid-phase microextraction based on an agarose-chitosan-multiwalled carbon nanotube composite film combined with HPLC-UV for the determination of non-steroidal anti-inflammatory drugs in aqueous samples.

    PubMed

    Wan Ibrahim, Wan Nazihah; Sanagi, Mohd Marsin; Mohamad Hanapi, Nor Suhaila; Kamaruzaman, Sazlinda; Yahaya, Noorfatimah; Wan Ibrahim, Wan Aini

    2018-06-07

    We describe the preparation, characterization and application of a composite film adsorbent based on blended agarose-chitosan-multi-walled carbon nanotubes for the preconcentration of selected non-steroidal anti-inflammatory drugs in aqueous samples before determination by high-performance liquid chromatography with UV detection. The composite film showed high surface area (4.0258 m 2 /g) and strong hydrogen bonding between multi-walled carbon nanotubes and agarose/chitosan matrix, which prevent adsorbent deactivation and ensure long-term stability. Several parameters, namely, sample pH, addition of salt, extraction time, desorption solvent and concentration of multi-walled carbon nanotubes in the composite film were optimized using a one-factor-at-time approach. The optimum extraction conditions obtained were as follows: isopropanol as conditioning solvent, 10 mL of sample solution at pH 2, extraction time of 30 min, stirring speed of 600 rpm, 100 μL of isopropanol as desorption solvent, desorption time of 5 min under ultrasonication, and 0.4% w/v of composite film. Under optimized conditions, the calibration curved showed good linearity in the range of 1-500 ng/mL (r 2  = 0.997-0.999), good limits of detection (0.89-8.05 ng/mL) were obtained with good relative standard deviations of < 4.59% (n = 3) for the determination of naproxen, diclofenac sodium salt and mefenamic acid drugs. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  11. Adaptive screening for depression--recalibration of an item bank for the assessment of depression in persons with mental and somatic diseases and evaluation in a simulated computer-adaptive test environment.

    PubMed

    Forkmann, Thomas; Kroehne, Ulf; Wirtz, Markus; Norra, Christine; Baumeister, Harald; Gauggel, Siegfried; Elhan, Atilla Halil; Tennant, Alan; Boecker, Maren

    2013-11-01

    This study conducted a simulation study for computer-adaptive testing based on the Aachen Depression Item Bank (ADIB), which was developed for the assessment of depression in persons with somatic diseases. Prior to computer-adaptive test simulation, the ADIB was newly calibrated. Recalibration was performed in a sample of 161 patients treated for a depressive syndrome, 103 patients from cardiology, and 103 patients from otorhinolaryngology (mean age 44.1, SD=14.0; 44.7% female) and was cross-validated in a sample of 117 patients undergoing rehabilitation for cardiac diseases (mean age 58.4, SD=10.5; 24.8% women). Unidimensionality of the itembank was checked and a Rasch analysis was performed that evaluated local dependency (LD), differential item functioning (DIF), item fit and reliability. CAT-simulation was conducted with the total sample and additional simulated data. Recalibration resulted in a strictly unidimensional item bank with 36 items, showing good Rasch model fit (item fit residuals<|2.5|) and no DIF or LD. CAT simulation revealed that 13 items on average were necessary to estimate depression in the range of -2 and +2 logits when terminating at SE≤0.32 and 4 items if using SE≤0.50. Receiver Operating Characteristics analysis showed that θ estimates based on the CAT algorithm have good criterion validity with regard to depression diagnoses (Area Under the Curve≥.78 for all cut-off criteria). The recalibration of the ADIB succeeded and the simulation studies conducted suggest that it has good screening performance in the samples investigated and that it may reasonably add to the improvement of depression assessment. © 2013.

  12. "It's for a good cause, isn't it?" - Exploring views of South African TB research participants on sample storage and re-use

    PubMed Central

    2012-01-01

    Background The banking of biological samples raises a number of ethical issues in relation to the storage, export and re-use of samples. Whilst there is a growing body of literature exploring participant perspectives in North America and Europe, hardly any studies have been reported in Africa. This is problematic in particular in light of the growing amount of research taking place in Africa, and with the rise of biobanking practices also on the African continent. In order to investigate the perspectives of African research participants, we conducted a study with research participants in a TB study in the Western Cape, South Africa. Methods Semi-structured interviews were conducted using an interview guide which drew on the most prominent themes expressed in current literature on sample storage, re-use and exportation. Interviews were conducted in Afrikaans and subsequently translated into English by the same interviewer. Interviews were transcribed verbatim and analysed qualitatively. Results The results of our study indicate that the majority of participants were supportive of giving one-time consent to the storage and re-use of their samples. The concept of research being for a “good cause” was a central prerequisite. Additionally, a significant minority requested that they be re-contacted if a future use was not stipulated on the original consent. There was also considerable variation in how participants understood the concept of a ‘good cause’, with participants describing three distinct categories of research, of which two were generally thought to constitute ‘good cause’ research. Research that was for-profit was considered to fall outside the spectrum of ‘good cause’ research. Participants displayed confidence in the abilities of the researchers to make future decisions regarding sample use, but seemed unaware of the role of ethics committees in either this process or more generally. Conclusions Participants expressed a wide and complex range of views about issues of sample storage and re-use, and they showed a great deal of trust in researchers. Participants’ willingness to have their samples stored and re-used is consistent with findings from existing studies. However, in contrast to existing literature, participants were generally not in favour of for-profit research. Further research needs to be done to explore these ideas in other communities, both in South Africa and other countries. PMID:22831568

  13. "It's for a good cause, isn't it?" - Exploring views of South African TB research participants on sample storage and re-use.

    PubMed

    van Schalkwyk, Gerrit; de Vries, Jantina; Moodley, Keymanthri

    2012-07-25

    The banking of biological samples raises a number of ethical issues in relation to the storage, export and re-use of samples. Whilst there is a growing body of literature exploring participant perspectives in North America and Europe, hardly any studies have been reported in Africa. This is problematic in particular in light of the growing amount of research taking place in Africa, and with the rise of biobanking practices also on the African continent. In order to investigate the perspectives of African research participants, we conducted a study with research participants in a TB study in the Western Cape, South Africa. Semi-structured interviews were conducted using an interview guide which drew on the most prominent themes expressed in current literature on sample storage, re-use and exportation. Interviews were conducted in Afrikaans and subsequently translated into English by the same interviewer. Interviews were transcribed verbatim and analysed qualitatively. The results of our study indicate that the majority of participants were supportive of giving one-time consent to the storage and re-use of their samples. The concept of research being for a "good cause" was a central prerequisite. Additionally, a significant minority requested that they be re-contacted if a future use was not stipulated on the original consent. There was also considerable variation in how participants understood the concept of a 'good cause', with participants describing three distinct categories of research, of which two were generally thought to constitute 'good cause' research. Research that was for-profit was considered to fall outside the spectrum of 'good cause' research. Participants displayed confidence in the abilities of the researchers to make future decisions regarding sample use, but seemed unaware of the role of ethics committees in either this process or more generally. Participants expressed a wide and complex range of views about issues of sample storage and re-use, and they showed a great deal of trust in researchers. Participants' willingness to have their samples stored and re-used is consistent with findings from existing studies. However, in contrast to existing literature, participants were generally not in favour of for-profit research. Further research needs to be done to explore these ideas in other communities, both in South Africa and other countries.

  14. Introducing a short version of the physical self description questionnaire: new strategies, short-form evaluative criteria, and applications of factor analyses.

    PubMed

    Marsh, Herbert W; Martin, Andrew J; Jackson, Susan

    2010-08-01

    Based on the Physical Self Description Questionnaire (PSDQ) normative archive (n = 1,607 Australian adolescents), 40 of 70 items were selected to construct a new short form (PSDQ-S). The PSDQ-S was evaluated in a new cross-validation sample of 708 Australian adolescents and four additional samples: 349 Australian elite-athlete adolescents, 986 Spanish adolescents, 395 Israeli university students, 760 Australian older adults. Across these six groups, the 11 PSDQ-S factors had consistently high reliabilities and invariant factor structures. Study 1, using a missing-by-design variation of multigroup invariance tests, showed invariance across 40 PSDQ-S items and 70 PSDQ items. Study 2 demonstrated factorial invariance over a 1-year interval (test-retest correlations .57-.90; Mdn = .77), and good convergent and discriminant validity in relation to time. Study 3 showed good and nearly identical support for convergent and discriminant validity of PSDQ and PSDQ-S responses in relation to two other physical self-concept instruments.

  15. Molecularly imprinted fluorescent hollow nanoparticles as sensors for rapid and efficient detection λ-cyhalothrin in environmental water.

    PubMed

    Wang, Jixiang; Qiu, Hao; Shen, Hongqiang; Pan, Jianming; Dai, Xiaohui; Yan, Yongsheng; Pan, Guoqing; Sellergren, Börje

    2016-11-15

    Molecularly imprinted fluorescent polymers have shown great promise in biological or chemical separations and detections, due to their high stability, selectivity and sensitivity. In this work, molecularly imprinted fluorescent hollow nanoparticles, which could rapidly and efficiently detect λ-cyhalothrin (a toxic insecticide) in water samples, was reported. The molecularly imprinted fluorescent sensor showed excellent sensitivity (the limit of detection low to 10.26nM), rapid detection rate (quantitative detection of λ-cyhalothrin within 8min), regeneration ability (maintaining good fluorescence properties after 8 cycling operation) and appreciable selectivity over several structural analogs. Moreover, the fluorescent sensor was further used to detect λ-cyhalothrin in real samples form the Beijing-Hangzhou Grand Canal Water. Despite the relatively complex components of the environmental water, the molecularly imprinted fluorescent hollow nanosensor still showed good recovery, clearly demonstrating the potential value of this smart sensor nanomaterial in environmental monitoring. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Photo-actuating materials based on elastomers and modified carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Czaniková, Klaudia; Krupa, Igor; Ilčíková, Markéta; Kasák, Peter; Chorvát, , Dušan; Valentin, Marian; Šlouf, Miroslav; Mosnáček, Jaroslav; Mičušík, Matej; Omastová, Mária

    2012-01-01

    The photo-actuating behavior of new polymeric nanocomposite materials based on a commercial elastomer, an ethylene-vinylacetate copolymer (EVA), filled with multiwalled carbon nanotubes (MWCNT) was investigated. A good dispersion of the MWCNT within the elastomeric matrix was ensured by using a novel, specific compatibilizer consisting of pyrenyl and cholesteryl groups. A uniaxial orientation of the MWCNT within the matrix was induced with shear forces by employing a special custom-made punch/die system. Good dispergation and alignment of the MWCNT within the matrix were demonstrated by scanning electron microscopy. Transmission electron microscopy showed a good dispersion of the MWCNT within the composite. Photo-actuation was qualitatively characterized by atomic force microscopy and quantitatively characterized by nanoindentation. The samples prepared in the form of Braille element showed expansion upon illumination by light diodes. The maximal height deformation changes about 15% was detected when a blue diode was used.

  17. Oral microbiota carriage in patients with multibracket appliance in relation to the quality of oral hygiene.

    PubMed

    Klaus, Katharina; Eichenauer, Johanna; Sprenger, Rhea; Ruf, Sabine

    2016-10-28

    The present study aimed to investigate the prevalence of oral microbiota (Candida species (spp.), Streptococcus mutans, and Lactobacilli) in patients with multibracket (MB) appliances in relation to the quality of oral hygiene. Saliva and plaque samples were collected from three groups of 25 patients each (good oral hygiene (GOH), poor oral hygiene (POH), and poor oral hygiene with white spot lesions (POH/WSL)). Counts of colony forming units (CFU) of the investigated oral microbiota were compared using Chi-square and Mann-Whitney U tests. Both saliva and plaque samples showed a high prevalence of Candida spp. in all patients (saliva: 73.4 %, plaque: 60.9 %). The main Candida species was C. albicans. The salivary CFU of Candida spp. in the GOH group was significantly lower than that in the POH group (p = 0.045) and POH/WSL group (p = 0.011). S. mutans was found in the saliva and plaque samples of all patients. Lactobacilli were found in the saliva samples of all patients and in 90.7 % of the plaque samples. In the saliva samples, the CFU of Lactobacilli were more numerous in the POH and POH/WSL groups than in the GOH group (p = 0.047). The investigated sample of patients showed a high carriage of oral Candida spp. Patients with WSL formation during MB appliance treatment exhibited higher counts of Candida and Lactobacilli compared with patients with good oral hygiene. Independent of oral hygiene quality, S. mutans was detected in all patients.

  18. Psychometric properties of the Satisfaction with Life Scale (SWLS): secondary analysis of the Mexican Health and Aging Study.

    PubMed

    López-Ortega, Mariana; Torres-Castro, Sara; Rosas-Carrasco, Oscar

    2016-12-09

    The Satisfaction with Life Scale (SWLS) has been widely used and has proven to be a valid and reliable instrument for assessing satisfaction with life in diverse population groups, however, research on satisfaction with life and validation of different measuring instruments in Mexican adults is still lacking. The objective was to evaluate the psychometric properties of the Satisfaction with Life Scale (SWLS) in a representative sample of Mexican adults. This is a methodological study to evaluate a satisfaction with life scale in a sample of 13,220 Mexican adults 50 years of age or older from the 2012 Mexican Health and Aging Study. The scale's reliability (internal consistency) was analysed using Cronbach's alpha and inter-item correlations. An exploratory factor analysis was also performed. Known-groups validity was evaluated comparing good-health and bad-health participants. Comorbidity, perceived financial situation, self-reported general health, depression symptoms, and social support were included to evaluate the validity between these measures and the total score of the scale using Spearman's correlations. The analysis of the scale's reliability showed good internal consistency (α = 0.74). The exploratory factor analysis confirmed the existence of a unique factor structure that explained 54% of the variance. SWLS was related to depression, perceived health, financial situation, and social support, and these relations were all statistically significant (P < .01). There was significant difference in life satisfaction between the good- and bad-health groups. Results show good internal consistency and construct validity of the SWLS. These results are comparable with results from previous studies. Meeting the study's objective to validate the scale, the results show that the Spanish version of the SWLS is a reliable and valid measure of satisfaction with life in the Mexican context.

  19. Inverse Ising Inference Using All the Data

    NASA Astrophysics Data System (ADS)

    Aurell, Erik; Ekeberg, Magnus

    2012-03-01

    We show that a method based on logistic regression, using all the data, solves the inverse Ising problem far better than mean-field calculations relying only on sample pairwise correlation functions, while still computationally feasible for hundreds of nodes. The largest improvement in reconstruction occurs for strong interactions. Using two examples, a diluted Sherrington-Kirkpatrick model and a two-dimensional lattice, we also show that interaction topologies can be recovered from few samples with good accuracy and that the use of l1 regularization is beneficial in this process, pushing inference abilities further into low-temperature regimes.

  20. Electronic and Vibrational Spectra of InP Quantum Dots Formed by Sequential Ion Implantation

    NASA Technical Reports Server (NTRS)

    Hall, C.; Mu, R.; Tung, Y. S.; Ueda, A.; Henderson, D. O.; White, C. W.

    1997-01-01

    We have performed sequential ion implantation of indium and phosphorus into silica combined with controlled thermal annealing to fabricate InP quantum dots in a dielectric host. Electronic and vibrational spectra were measured for the as-implanted and annealed samples. The annealed samples show a peak in the infrared spectra near 320/cm which is attributed to a surface phonon mode and is in good agreement with the value calculated from Frolich's theory of surface phonon polaritons. The electronic spectra show the development of a band near 390 nm that is attributed to quantum confined InP.

  1. A selective electromembrane extraction of uranium (VI) prior to its fluorometric determination in water.

    PubMed

    Davarani, Saied Saeed Hosseiny; Moazami, Hamid Reza; Keshtkar, Ali Reza; Banitaba, Mohammad Hossein; Nojavan, Saeed

    2013-06-14

    A novel method for the selective electromembrane extraction (EME) of U(6+) prior to fluorometric determination has been proposed. The effect of extraction conditions including supported liquid membrane (SLM) composition, extraction time and extraction voltage were investigated. An SLM composition of 1% di-2-ethyl hexyl phosphonic acid in nitrophenyl octyl ether (NPOE) showed good selectivity, recovery and enrichment factor. The best performance was achieved at an extraction potential of 80 volts and an extraction time of 14 minutes Under the optimized conditions, a linear range from 1 to 1000 ng mL(-1) and LOD of 0.1 ng mL(-1) were obtained for the determination of U(6+). The EME method showed good performance in sample cleanup and the reduction of the interfering effects of Mn(2+), Zn(2+), Cd(2+), Ni(2+), Fe(3+), Co(2+), Cu(2+), Cl(-) and PO4(3-) ions during fluorometric determination of uranium in real water samples. The recoveries above 54% and enrichment factors above 64.7 were obtained by the proposed method for real sample analysis. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Reliability of conventional shade guides in teeth color determination.

    PubMed

    Todorović, Ana; Todorović, Aleksandar; Gostović, Aleksandra Spadijer; Lazić, Vojkan; Milicić, Biljana; Djurisić, Slobodan

    2013-10-01

    Color matching in prosthodontic therapy is a very important task because it influences the esthetic value of dental restorations. Visual shade matching represents the most frequently applied method in clinical practice. Instrumental measurements provide objective and quantified data in color assessment of natural teeth and restorations. In instrumental shade analysis, the goal is to achieve the smallest deltaE value possible, indicating the most accurate shade match. The aim of this study was to evaluate the reliability of commercially available ceramic shade guides. VITA Easyshade spectrophotometer (VITA, Germany) was used for instrumental color determination. Utilizing this device, color samples of ten VITA Classical and ten VITA 3D - Master shade guides were analyzed. Each color sample from all shade guides was measured three times and the basic parameters of color quality were examined: deltaL, deltaC, deltaH, deltaE, deltaElc. Based on these parameters spectrophotometer marks the shade matching as good, fair or adjust. After performing 1,248 measurements of ceramic color samples, frequency of evaluations adjust, fair and good were statistically significantly different between VITA Classical and VITA 3D Master shade guides (p = 0.002). There were 27.1% cases scored as adjust, 66.3% as fair and 6.7% as good. In VITA 3D - Master shade guides 30.9% cases were evaluated as adjust, 66.4% as fair and 2.7% cases as good. Color samples from different shade guides, produced by the same manufacturer, show variability in basic color parameters, which once again proves the lack of precision and nonuniformity of the conventional method.

  3. Assessment of groundwater quality: a fusion of geochemical and geophysical information via Bayesian neural networks.

    PubMed

    Maiti, Saumen; Erram, V C; Gupta, Gautam; Tiwari, Ram Krishna; Kulkarni, U D; Sangpal, R R

    2013-04-01

    Deplorable quality of groundwater arising from saltwater intrusion, natural leaching and anthropogenic activities is one of the major concerns for the society. Assessment of groundwater quality is, therefore, a primary objective of scientific research. Here, we propose an artificial neural network-based method set in a Bayesian neural network (BNN) framework and employ it to assess groundwater quality. The approach is based on analyzing 36 water samples and inverting up to 85 Schlumberger vertical electrical sounding data. We constructed a priori model by suitably parameterizing geochemical and geophysical data collected from the western part of India. The posterior model (post-inversion) was estimated using the BNN learning procedure and global hybrid Monte Carlo/Markov Chain Monte Carlo optimization scheme. By suitable parameterization of geochemical and geophysical parameters, we simulated 1,500 training samples, out of which 50 % samples were used for training and remaining 50 % were used for validation and testing. We show that the trained model is able to classify validation and test samples with 85 % and 80 % accuracy respectively. Based on cross-correlation analysis and Gibb's diagram of geochemical attributes, the groundwater qualities of the study area were classified into following three categories: "Very good", "Good", and "Unsuitable". The BNN model-based results suggest that groundwater quality falls mostly in the range of "Good" to "Very good" except for some places near the Arabian Sea. The new modeling results powered by uncertainty and statistical analyses would provide useful constrain, which could be utilized in monitoring and assessment of the groundwater quality.

  4. Sensitive determination of polycyclic aromatic hydrocarbons in water samples by HPLC coupled with SPE based on graphene functionalized with triethoxysilane.

    PubMed

    Huang, Ke-Jing; Li, Jing; Liu, Yan-Ming; Wang, Lan

    2013-02-01

    The graphene functionalized with (3-aminopropyl) triethoxysilane was synthesized by a simple hydrothermal reaction and applied as SPE sorbents to extract trace polycyclic aromatic hydrocarbons (PAHs) from environmental water samples. These sorbents possess high adsorption capacity and extraction efficiency due to strong adsorption ability of carbon materials and large specific surface area of nanoparticles, and only 10 mg of sorbents are required to extract PAHs from 100 mL water samples. Several condition parameters, such as eluent and its volume, adsorbent amount, sample volume, sample pH, and sample flow rate, were optimized to achieve good sensitivity and precision. Under the optimized extraction conditions, the method showed good linearity in the range of 1-100 μg/L, repeatability of the extraction (the RSDs were between 1.8 and 2.9%, n = 6), and satisfactory detection limits of 0.029-0.1 μg/L. The recoveries of PAHs spiked in environmental water samples ranged from 84.6 to 109.5%. All these results demonstrated that this new SPE technique was a viable alternative to conventional enrichment techniques for the extraction and analysis of PAHs in complex samples. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. A pressure-affected headspace-gas chromatography method for determining calcium carbonate content in paper sample.

    PubMed

    Dai, Yi; Yu, Zhen-Hua; Zhan, Jian-Bo; Chai, Xin-Sheng; Zhang, Shu-Xin; Xie, Wei-Qi; He, Liang

    2017-07-21

    The present work reports on the development of a pressure-affected based headspace (HS) analytical technique for the determination of calcium carbonate content in paper samples. By the acidification, the carbonate in the sample was converted to CO 2 and released into the headspace of a closed vial and then measured by gas chromatography (GC). When the amount of carbonate in the sample is significant, the pressure created by the CO 2 affects the accuracy of the method. However, the pressure also causes a change in the O 2 signal in the HS-GC measurement, which is a change that can be used as an indirect measure of the carbonate in the sample. The results show that the present method has a good precision (the relative standard deviation<2.32%), and good accuracy (the relative differences compared to a reference method was<5.76%). Coupled with the fact that the method is simple, rapid, and accurate, it is suitable for a variety of applications that call for the analysis of high carbonate content in paper samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. [A quickly methodology for drug intelligence using profiling of illicit heroin samples].

    PubMed

    Zhang, Jianxin; Chen, Cunyi

    2012-07-01

    The aim of the paper was to evaluate a link between two heroin seizures using a descriptive method. The system involved the derivation and gas chromatographic separation of samples followed by a fully automatic data analysis and transfer to a database. Comparisons used the square cosine function between two chromatograms assimilated to vectors. The method showed good discriminatory capabilities. The probability of false positives was extremely slight. In conclusion, this method proved to be efficient and reliable, which appeared suitable for estimating the links between illicit heroin samples.

  7. Validation to Portuguese of the Scale of Student Satisfaction and Self-Confidence in Learning1

    PubMed Central

    Almeida, Rodrigo Guimarães dos Santos; Mazzo, Alessandra; Martins, José Carlos Amado; Baptista, Rui Carlos Negrão; Girão, Fernanda Berchelli; Mendes, Isabel Amélia Costa

    2015-01-01

    Objective: translate and validate to Portuguese the Scale of Student Satisfaction and Self-Confidence in Learning. Material and Methods: methodological translation and validation study of a research tool. After following all steps of the translation process, for the validation process, the event III Workshop Brazil - Portugal: Care Delivery to Critical Patients was created, promoted by one Brazilian and another Portuguese teaching institution. Results: 103 nurses participated. As to the validity and reliability of the scale, the correlation pattern between the variables, the sampling adequacy test (Kaiser-Meyer-Olkin) and the sphericity test (Bartlett) showed good results. In the exploratory factorial analysis (Varimax), item 9 behaved better in factor 1 (Satisfaction) than in factor 2 (Self-confidence in learning). The internal consistency (Cronbach's alpha) showed coefficients of 0.86 in factor 1 with six items and 0.77 for factor 2 with 07 items. Conclusion: in Portuguese this tool was called: Escala de Satisfação de Estudantes e Autoconfiança na Aprendizagem. The results found good psychometric properties and a good potential use. The sampling size and specificity are limitations of this study, but future studies will contribute to consolidate the validity of the scale and strengthen its potential use. PMID:26625990

  8. The Students' Perceptions of School Success Promoting Strategies Inventory (SPSI): development and validity evidence based studies.

    PubMed

    Moreira, Paulo A S; Oliveira, João Tiago; Dias, Paulo; Vaz, Filipa Machado; Torres-Oliveira, Isabel

    2014-08-04

    Students' perceptions about school success promotion strategies are of great importance for schools, as they are an indicator of how students perceive the school success promotion strategies. The objective of this study was to develop and analyze the validity evidence based of The Students' Perceptions of School Success Promoting Strategies Inventory (SPSI), which assesses both individual students' perceptions of their school success promoting strategies, and dimensions of school quality. A structure of 7 related factors was found, which showed good adjustment indices in two additional different samples, suggesting that this is a well-fitting multi-group model (p < .001). All scales presented good reliability values. Schools with good academic results registered higher values in Career development, Active learning, Proximity, Educational Technologies and Extra-curricular activities (p < .05). SPSI showed to be adequate to measure within-schools (students within schools) dimensions of school success. In addition, there is preliminary evidence for its adequacy for measuring school success promotion dimensions between schools for 4 dimensions. This study supports the validity evidence based of the SPSI (validity evidence based on test content, on internal structure, on relations to other variables and on consequences of testing). Future studies should test for within- and between-level variance in a bigger sample of schools.

  9. An Approach to the Use of Depth Cameras for Weed Volume Estimation

    PubMed Central

    Andújar, Dionisio; Dorado, José; Fernández-Quintanilla, César; Ribeiro, Angela

    2016-01-01

    The use of depth cameras in precision agriculture is increasing day by day. This type of sensor has been used for the plant structure characterization of several crops. However, the discrimination of small plants, such as weeds, is still a challenge within agricultural fields. Improvements in the new Microsoft Kinect v2 sensor can capture the details of plants. The use of a dual methodology using height selection and RGB (Red, Green, Blue) segmentation can separate crops, weeds, and soil. This paper explores the possibilities of this sensor by using Kinect Fusion algorithms to reconstruct 3D point clouds of weed-infested maize crops under real field conditions. The processed models showed good consistency among the 3D depth images and soil measurements obtained from the actual structural parameters. Maize plants were identified in the samples by height selection of the connected faces and showed a correlation of 0.77 with maize biomass. The lower height of the weeds made RGB recognition necessary to separate them from the soil microrelief of the samples, achieving a good correlation of 0.83 with weed biomass. In addition, weed density showed good correlation with volumetric measurements. The canonical discriminant analysis showed promising results for classification into monocots and dictos. These results suggest that estimating volume using the Kinect methodology can be a highly accurate method for crop status determination and weed detection. It offers several possibilities for the automation of agricultural processes by the construction of a new system integrating these sensors and the development of algorithms to properly process the information provided by them. PMID:27347972

  10. An Approach to the Use of Depth Cameras for Weed Volume Estimation.

    PubMed

    Andújar, Dionisio; Dorado, José; Fernández-Quintanilla, César; Ribeiro, Angela

    2016-06-25

    The use of depth cameras in precision agriculture is increasing day by day. This type of sensor has been used for the plant structure characterization of several crops. However, the discrimination of small plants, such as weeds, is still a challenge within agricultural fields. Improvements in the new Microsoft Kinect v2 sensor can capture the details of plants. The use of a dual methodology using height selection and RGB (Red, Green, Blue) segmentation can separate crops, weeds, and soil. This paper explores the possibilities of this sensor by using Kinect Fusion algorithms to reconstruct 3D point clouds of weed-infested maize crops under real field conditions. The processed models showed good consistency among the 3D depth images and soil measurements obtained from the actual structural parameters. Maize plants were identified in the samples by height selection of the connected faces and showed a correlation of 0.77 with maize biomass. The lower height of the weeds made RGB recognition necessary to separate them from the soil microrelief of the samples, achieving a good correlation of 0.83 with weed biomass. In addition, weed density showed good correlation with volumetric measurements. The canonical discriminant analysis showed promising results for classification into monocots and dictos. These results suggest that estimating volume using the Kinect methodology can be a highly accurate method for crop status determination and weed detection. It offers several possibilities for the automation of agricultural processes by the construction of a new system integrating these sensors and the development of algorithms to properly process the information provided by them.

  11. Non-enzymatic electrochemical glucose sensor based on NiMoO4 nanorods

    NASA Astrophysics Data System (ADS)

    Wang, Dandan; Cai, Daoping; Huang, Hui; Liu, Bin; Wang, Lingling; Liu, Yuan; Li, Han; Wang, Yanrong; Li, Qiuhong; Wang, Taihong

    2015-04-01

    A non-enzymatic glucose sensor based on the NiMoO4 nanorods has been fabricated for the first time. The electrocatalytic performance of the NiMoO4 nanorods’ modified electrode toward glucose oxidation was evaluated by cyclic voltammetry and amperometry. The NiMoO4 nanorods’ modified electrode showed a greatly enhanced electrocatalytic property toward glucose oxidation, as well as an excellent anti-interference and a good stability. Impressively, good accuracy and high precision for detecting glucose concentration in human serum samples were obtained. These excellent sensing properties, combined with good reproducibility and low cost, indicate that NiMoO4 nanorods are a promising candidate for non-enzymatic glucose sensors.

  12. Studies of tin-transition metal-carbon and tin-cobalt-transition metal-carbon negative electrode materials prepared by mechanical attrition

    NASA Astrophysics Data System (ADS)

    Ferguson, P. P.; Martine, M. L.; George, A. E.; Dahn, J. R.

    Samples of Sn 30TM 30C 40 and of Sn 30Co 15TM 15C 40, with TM = 3d transition metals, were prepared by vertical-axis attritor milling. The structure and performance of these samples were studied by X-ray diffraction (XRD) and by electrochemical testing. The XRD patterns of Sn 30TM 30C 40 show an amorphous-like diffraction pattern only for the sample with TM = Co. The other prepared samples show broadened Bragg peaks of their main starting material, along with an amorphous-like background, even after 32 h of milling. Samples with TM = Co and TM = Ni show stable differential capacity versus potential plots and stable cycling for at least 100 cycles with reversible capacities of 425 and 250 mAh g -1, respectively. All samples prepared with 15 at.% Co show good capacity retention for at least 100 cycles ranging from 270 mAh g -1 for samples with TM = Ni to 500 mAh g -1 for samples with TM = Ti. The differential capacity versus potential plots for all the prepared Sn 30Co 15TM 15C 40 samples show similar structure to that of Sn 30Co 30C 40 except when TM = Cu. This shows the possibility of preparing tin-based negative electrode materials using a combination of cobalt and TM, especially if one looks to reduce the cobalt content.

  13. Quality-Assurance Data for Routine Water Analyses by the U.S. Geological Survey Laboratory in Troy, New York-July 1997 through June 1999

    USGS Publications Warehouse

    Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.

    2006-01-01

    The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance/quality-control data for the time period addressed in this report were stored in the laboratory's SAS data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality- control samples analyzed from July 1997 through June 1999. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration and (or) low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, ammonium, calcium, chloride, specific conductance, and sulfate. The data from the potassium and sodium analytical procedures are insufficient for evaluation. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 11 of 13 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. Blank analysis results for chloride showed that 22 percent of blanks did not meet data-quality objectives and results for dissolved organic carbon showed that 31 percent of the blanks did not meet data-quality objectives. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 14 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except total aluminum (70 percent of samples met objectives) and potassium (83 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality for most constituents over the time period. The P-sample (low-ionic-strength constituents) analysis had good ratings in two of these studies and a satisfactory rating in the third. The results of the T-sample (trace constituents) analysis indicated high data quality with good ratings in all three studies. The N-sample (nutrient constituents) studies had one each of excellent, good, and satisfactory ratings. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 80 percent of the samples met data-quality objectives for 9 of the 13 analytes; the exceptions were dissolved organic carbon, ammonium, chloride, and specific conductance. Data-quality objectives were not met for dissolved organic carbon in two NWRI studies, but all of the samples were within control limits for the last study. Data-quality objectives were not met in 41 percent of samples analyzed for ammonium, 25 percent of samples analyzed for chloride, and 30 percent of samples analyzed for specific conductance. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 84 percent of the samples analyzed for calcium, chloride, magnesium, pH, and potassium. Data-quality objectives were met by 73 percent of those analyzed for sulfate. The data-quality objective was not met for sodium. The data are insufficient for evaluation of the specific conductance results.

  14. Reliability and Validity of Assessing User Satisfaction With Web-Based Health Interventions

    PubMed Central

    Lehr, Dirk; Reis, Dorota; Vis, Christiaan; Riper, Heleen; Berking, Matthias; Ebert, David Daniel

    2016-01-01

    Background The perspective of users should be taken into account in the evaluation of Web-based health interventions. Assessing the users’ satisfaction with the intervention they receive could enhance the evidence for the intervention effects. Thus, there is a need for valid and reliable measures to assess satisfaction with Web-based health interventions. Objective The objective of this study was to analyze the reliability, factorial structure, and construct validity of the Client Satisfaction Questionnaire adapted to Internet-based interventions (CSQ-I). Methods The psychometric quality of the CSQ-I was analyzed in user samples from 2 separate randomized controlled trials evaluating Web-based health interventions, one from a depression prevention intervention (sample 1, N=174) and the other from a stress management intervention (sample 2, N=111). At first, the underlying measurement model of the CSQ-I was analyzed to determine the internal consistency. The factorial structure of the scale and the measurement invariance across groups were tested by multigroup confirmatory factor analyses. Additionally, the construct validity of the scale was examined by comparing satisfaction scores with the primary clinical outcome. Results Multigroup confirmatory analyses on the scale yielded a one-factorial structure with a good fit (root-mean-square error of approximation =.09, comparative fit index =.96, standardized root-mean-square residual =.05) that showed partial strong invariance across the 2 samples. The scale showed very good reliability, indicated by McDonald omegas of .95 in sample 1 and .93 in sample 2. Significant correlations with change in depressive symptoms (r=−.35, P<.001) and perceived stress (r=−.48, P<.001) demonstrated the construct validity of the scale. Conclusions The proven internal consistency, factorial structure, and construct validity of the CSQ-I indicate a good overall psychometric quality of the measure to assess the user’s general satisfaction with Web-based interventions for depression and stress management. Multigroup analyses indicate its robustness across different samples. Thus, the CSQ-I seems to be a suitable measure to consider the user’s perspective in the overall evaluation of Web-based health interventions. PMID:27582341

  15. Reliability and Validity of Assessing User Satisfaction With Web-Based Health Interventions.

    PubMed

    Boß, Leif; Lehr, Dirk; Reis, Dorota; Vis, Christiaan; Riper, Heleen; Berking, Matthias; Ebert, David Daniel

    2016-08-31

    The perspective of users should be taken into account in the evaluation of Web-based health interventions. Assessing the users' satisfaction with the intervention they receive could enhance the evidence for the intervention effects. Thus, there is a need for valid and reliable measures to assess satisfaction with Web-based health interventions. The objective of this study was to analyze the reliability, factorial structure, and construct validity of the Client Satisfaction Questionnaire adapted to Internet-based interventions (CSQ-I). The psychometric quality of the CSQ-I was analyzed in user samples from 2 separate randomized controlled trials evaluating Web-based health interventions, one from a depression prevention intervention (sample 1, N=174) and the other from a stress management intervention (sample 2, N=111). At first, the underlying measurement model of the CSQ-I was analyzed to determine the internal consistency. The factorial structure of the scale and the measurement invariance across groups were tested by multigroup confirmatory factor analyses. Additionally, the construct validity of the scale was examined by comparing satisfaction scores with the primary clinical outcome. Multigroup confirmatory analyses on the scale yielded a one-factorial structure with a good fit (root-mean-square error of approximation =.09, comparative fit index =.96, standardized root-mean-square residual =.05) that showed partial strong invariance across the 2 samples. The scale showed very good reliability, indicated by McDonald omegas of .95 in sample 1 and .93 in sample 2. Significant correlations with change in depressive symptoms (r=-.35, P<.001) and perceived stress (r=-.48, P<.001) demonstrated the construct validity of the scale. The proven internal consistency, factorial structure, and construct validity of the CSQ-I indicate a good overall psychometric quality of the measure to assess the user's general satisfaction with Web-based interventions for depression and stress management. Multigroup analyses indicate its robustness across different samples. Thus, the CSQ-I seems to be a suitable measure to consider the user's perspective in the overall evaluation of Web-based health interventions.

  16. A High-Precision Counter Using the DSP Technique

    DTIC Science & Technology

    2004-09-01

    DSP is not good enough to process all the 1-second samples. The cache memory is also not sufficient to store all the sampling data. So we cut the...sampling number in a cycle is not good enough to achieve an accuracy less than 2×10-11. For this reason, a correlation operation is performed for... not good enough to process all the 1-second samples. The cache memory is also not sufficient to store all the sampling data. We will solve this

  17. Rapid determination of moisture content in paper materials by multiple headspace extraction gas chromatography.

    PubMed

    Xie, Wei-Qi; Chai, Xin-Sheng

    2016-04-22

    This paper describes a new method for the rapid determination of the moisture content in paper materials. The method is based on multiple headspace extraction gas chromatography (MHE-GC) at a temperature above the boiling point of water, from which an integrated water loss from the tested sample due to evaporation can be measured and from which the moisture content in the sample can be determined. The results show that the new method has a good precision (with the relative standard deviation <0.96%), high sensitivity (the limit of quantitation=0.005%) and good accuracy (the relative differences <1.4%). Therefore, the method is quite suitable for many uses in research and industrial applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Electron paramagnetic resonance in Cu-doped ZnO

    NASA Astrophysics Data System (ADS)

    Buchheit, R.; Acosta-Humánez, F.; Almanza, O.

    2016-04-01

    In this work, ZnO and Cu-doped ZnO nanoparticles (Zn1-xCuxO, x = 3%), with a calcination temperature of 500∘C were synthesized using the sol-gel method. The particles were analyzed using atomic absorption spectroscopy (AAS), X-ray diffraction (XRD) and electron paramagnetic resonance (EPR) at X-band, measurement in a temperature range from 90 K to room temperature. AAS confirmed a good correspondence between the experimental doping concentration and the theoretical value. XRD reveals the presence of ZnO phase in hexagonal wurtzite structure and a nanoparticle size for the samples synthesized. EPR spectroscopy shows the presence of point defects in both samples with g-values of g = 1.959 for shallow donors and g = 2.004 for ionized vacancies. It is important when these materials are required have been used as catalysts, as suggested that it is not necessary prepare them at higher temperature. A simulation of the Cu EPR signal using an anisotropic spin Hamiltonian was performed and showed good coincidence with the experimental spectra. It was shown that Cu2+ ions enter interstitial octahedral sites of orthorhombic symmetry in the wurtzite crystal structure. Temperature dependence of the EPR linewidth and signal intensity shows a paramagnetic behavior of the sample in the measurement range. A Néel temperature TN = 78 ± 19 K was determined.

  19. Quality parameters and antioxidant and antibacterial properties of some Mexican honeys.

    PubMed

    Rodríguez, Beatriz A; Mendoza, Sandra; Iturriga, Montserrat H; Castaño-Tostado, Eduardo

    2012-01-01

    A total of 14 Mexican honeys were screened for quality parameters including color, moisture, proline, and acidity. Antioxidant properties of complete honey and its methanolic extracts were evaluated by the DPPH, ABTS, and FRAP assays. In addition, the antimicrobial activity of complete honeys against Bacillus cereus ATCC 10876, Listeria monocytogenes Scott A, Salmonella Typhimurium ATCC 14028, and Sthapylococcus aureus ATCC 6538 was determined. Most of honeys analyzed showed values within quality parameters established by the Codex Alimentarius Commission in 2001. Eucalyptus flower honey and orange blossom honey showed the highest phenolic contents and antioxidant capacity. Bell flower, orange blossom, and eucalyptus flower honeys inhibited the growth of the 4 evaluated microorganisms. The remaining honeys affected at least 1 of the estimated growth parameters (increased lag phase, decreased growth rate, and/or maximum population density). Microorganism sensitivity to the antimicrobial activity of honeys followed the order B. cereus > L. monocytogenes > Salmonella Typhimurium > S. aureus. The monofloral honey samples from orange blossoms, and eucalyptus flowers demonstrated to be good sources of antioxidant and antimicrobial compounds. All the Mexican honey samples examined proved to be good sources of antioxidants and antimicrobial agents that might serve to maintain health and protect against several diseases. The results of the study showed that Mexican honeys display good quality parameters and antioxidant and antimicrobial activities. Mexican honey can be used as an additive in the food industry to increase the nutraceutical value of products. © 2011 Institute of Food Technologists®

  20. Performance evaluation of Abbott CELL-DYN Ruby for routine use.

    PubMed

    Lehto, T; Hedberg, P

    2008-10-01

    CELL-DYN Ruby is a new automated hematology analyzer suitable for routine use in small laboratories and as a back-up or emergency analyzer in medium- to high-volume laboratories. The analyzer was evaluated by comparing the results from the CELL-DYN((R)) Ruby with the results obtained from CELL-DYN Sapphire . Precision, linearity, and carryover between patient samples were also assessed. Precision was good at all levels for the routine cell blood count (CBC) parameters, CV% being or= 0.98) with CELL-DYN Sapphire for the CBC parameters. For the absolute reticulocyte count, R(2) was 0.82. In the white blood cell (WBC) differentials, the between-days precision was good for all parameters (CV%: or= 0.97), and the correlation coefficient for absolute monocyte count and monocyte percentage were 0.91 and 0.87, respectively. For absolute basophil count and basophil percentage the correlations were weaker (R(2) = 0.46 and 0.34, respectively). Carryover was minimal for all the parameters studied. The linearities of WBC, red blood cell, PLTs, and hemoglobin were acceptable within the tested ranges. In conclusion, the results of the evaluation showed the performance of CELL-DYN Ruby to be good.

  1. Thermoluminescence (TL) dosimeter of dysprosium doped strontium borate glass for different glass modifiers (Na, Li, Ca) subjected from 1 to 9 Gy doses

    NASA Astrophysics Data System (ADS)

    Hamzah, S. A.; Saeed, M. A.; Wagiran, H.; Hashim, I. H.

    2017-10-01

    This article reports TL response for different glass modifier and doping concentration. Alkali oxides (Na2O and Li2O) and alkali earth oxide (CaO) will be used as a glass modifier for strontium borate based glass. The samples were prepared by melt quenching technique. Dy2O3 concentrations ranging from 0.00 to 0.70 mol% and exposure doses of 1 to 9 Gy will be varied. All glass samples exhibit the prominent peak temperature positioned at 186 oC to 232 oC. From all the samples, one of the samples shows an excellent linearity dose response, higher TL and show good reproducibility after 5 cycles exposure which is sodium strontium borate doped with 0.1 mol% Dy2O3 (optimum concentration).

  2. Light stabilizers added to the shell of co-extruded wood/high-density polyethylene composites to improve mechanical and anti-UV ageing properties

    PubMed Central

    Mei, Changtong; Xu, Bing; Chen, Weimin; Yong, Cheng; Wang, Ke; Wu, Qinglin

    2018-01-01

    Weathering of wood--plastic composites (WPCs) leads to discoloration and cracks, which greatly limits their outdoor application. In this study, light stabilizers (including UV-327, HS-944 and nano-SiO2) were added to the shell of a co-extruded high-density polyethylene-based WPC to improve its anti-ultraviolet (UV) ageing properties and simultaneously to maintain its good mechanical properties. The results showed that UV-327 was the most effective light stabilizer for improving the mechanical and anti-UV ageing properties of the composites among the three stabilizers used. WPC samples combined with 2% UV-327 had the highest retention rates in flexural strength and also had the smoothest surface after 2500 h of UV ageing. The samples with 2% UV-327 added had the best protection for discoloration, showing the lowest values of ΔE* (colour difference) and ΔL* (luminescence) in all samples after 2500 h of UV ageing. WPC samples with 2% UV-327 were also oxidized the least after 2500 h of UV ageing. The results reported herein serve to enhance our understanding of the efficiency of light stabilizers in preventing UV degradation of WPCs, with a view to developing co-extruded WPCs with low cost, high anti-UV ageing properties and good mechanical properties for outdoor applications. PMID:29892445

  3. Automated system for on-line desorption of dried blood spots applied to LC/MS/MS pharmacokinetic study of flurbiprofen and its metabolite.

    PubMed

    Déglon, Julien; Thomas, Aurélien; Daali, Youssef; Lauer, Estelle; Samer, Caroline; Desmeules, Jules; Dayer, Pierre; Mangin, Patrice; Staub, Christian

    2011-01-25

    This paper illustrates the development of an automated system for the on-line bioanalysis of dried blood spots (on-line DBS). In this way, a prototype was designed for integration into a conventional LC/MS/MS, allowing the successive extraction of 30 DBS toward the analytical system without any sample pretreatment. The developed method was assessed for the DBS analysis of flurbiprofen (FLB) and its metabolite 4-hydroxyflurbiprofen (OH-FLB) in human whole blood (i.e. 5 μL). The automated procedure was fully validated based on international criteria and showed good precision, trueness, and linearity over the expected concentration range (from 10 to 1000 ng/mL and 100 to 10,000 ng/mL for OH-FLB and FLB respectively). Furthermore, the prototype showed good results in terms of recovery and carry-over. Stability of both analytes on filter paper was also investigated and the results suggested that DBS could be stored at ambient temperature for over 1 month. The on-line DBS automated system was then successfully applied to a pharmacokinetic study performed on healthy male volunteers after oral administration of a single 50-mg dose of FLB. Additionally, a comparison between finger capillary DBS and classic venous plasma concentrations was investigated. A good correlation was observed, demonstrating the complementarity of both sampling forms. The automated system described in this article represents an efficient tool for the LC/MS/MS analysis of DBS samples in many bioanalytical applications. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Polypyrrole-magnetite dispersive micro-solid-phase extraction combined with ultraviolet-visible spectrophotometry for the determination of rhodamine 6G and crystal violet in textile wastewater.

    PubMed

    Kamaruddin, Amirah Farhan; Sanagi, Mohd Marsin; Wan Ibrahim, Wan Aini; Md Shukri, Dyia S; Abdul Keyon, Aemi S

    2017-11-01

    Polypyrrole-magnetite dispersive micro-solid-phase extraction method combined with ultraviolet-visible spectrophotometry was developed for the determination of selected cationic dyes in textile wastewater. Polypyrrole-magnetite was used as adsorbent due to its thermal stability, magnetic properties, and ability to adsorb Rhodamine 6G and crystal violet. Dispersive micro-solid-phase extraction parameters were optimized, including sample pH, adsorbent amount, extraction time, and desorption solvent. The optimum polypyrrole-magnetite dispersive micro-solid phase-extraction conditions were sample pH 8, 60 mg polypyrrole-magnetite adsorbent, 5 min of extraction time, and acetonitrile as the desorption solvent. Under the optimized conditions, the polypyrrole-magnetite dispersive micro-solid-phase extraction with ultraviolet-visible method showed good linearity in the range of 0.05-7 mg/L (R 2  > 0.9980). The method also showed a good limit of detection for the dyes (0.05 mg/L) and good analyte recoveries (97.4-111.3%) with relative standard deviations < 10%. The method was successfully applied to the analysis of dyes in textile wastewater samples where the concentration found was 1.03 mg (RSD ±7.9%) and 1.13 mg/L (RSD ± 4.6%) for Rhodamine 6G and crystal violet, respectively. It can be concluded that this method can be adopted for the rapid extraction and determination of dyes at trace concentration levels. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Sub-Nyquist Sampling and Moire-Like Waveform Distortions

    NASA Technical Reports Server (NTRS)

    Williams, Glenn L.

    2000-01-01

    Investigations of aliasing effects in digital waveform sampling have revealed the existence of a mathematical field and a pseudo-alias domain lying to the left of a "Nyquist line" in a plane defining the boundary between two domains of sampling. To the right of the line lies the classic alias domain. For signals band-limited below the Nyquist limit, displayed output may show a false modulation envelope. The effect occurs whenever the sample rate and the signal frequency are related by ratios of mutually prime integers. Belying the principal of a 10:1 sampling ratio being "good enough", this distortion easily occurs in graphed one-dimensional waveforms and two-dimensional images and occurs daily on television.

  6. Sparse magnetic resonance imaging reconstruction using the bregman iteration

    NASA Astrophysics Data System (ADS)

    Lee, Dong-Hoon; Hong, Cheol-Pyo; Lee, Man-Woo

    2013-01-01

    Magnetic resonance imaging (MRI) reconstruction needs many samples that are sequentially sampled by using phase encoding gradients in a MRI system. It is directly connected to the scan time for the MRI system and takes a long time. Therefore, many researchers have studied ways to reduce the scan time, especially, compressed sensing (CS), which is used for sparse images and reconstruction for fewer sampling datasets when the k-space is not fully sampled. Recently, an iterative technique based on the bregman method was developed for denoising. The bregman iteration method improves on total variation (TV) regularization by gradually recovering the fine-scale structures that are usually lost in TV regularization. In this study, we studied sparse sampling image reconstruction using the bregman iteration for a low-field MRI system to improve its temporal resolution and to validate its usefulness. The image was obtained with a 0.32 T MRI scanner (Magfinder II, SCIMEDIX, Korea) with a phantom and an in-vivo human brain in a head coil. We applied random k-space sampling, and we determined the sampling ratios by using half the fully sampled k-space. The bregman iteration was used to generate the final images based on the reduced data. We also calculated the root-mean-square-error (RMSE) values from error images that were obtained using various numbers of bregman iterations. Our reconstructed images using the bregman iteration for sparse sampling images showed good results compared with the original images. Moreover, the RMSE values showed that the sparse reconstructed phantom and the human images converged to the original images. We confirmed the feasibility of sparse sampling image reconstruction methods using the bregman iteration with a low-field MRI system and obtained good results. Although our results used half the sampling ratio, this method will be helpful in increasing the temporal resolution at low-field MRI systems.

  7. Synthesis and Thermal Characterization of Hydroxyapatite Powders Obtained by Sol-Gel Technique

    NASA Astrophysics Data System (ADS)

    Jiménez-Flores, Y.; Camacho, N.; Rojas-Trigos, J. B.; Suárez, M.

    The development of bioactive materials presents an interesting and an extremely relevant problem to solve, in the development of customized cranial and maxillofacial prosthesis, bioactive coating, and cements, for example. In such areas, one of the more employed materials is the synthetic hydroxyapatite, due to its proved biocompatibility with the human body; however, there are few studies about the thermal affinity with the biological surroundings, and most of them are centered in the thermal stability of the hydroxyapatite instead of its transient thermal response. In the present paper, the synthesis and physical-chemical characterization of hydroxyapatite samples, obtained by the sol-gel technique employing ultrasonic mixing, are reported. Employing X-ray diffraction patterns, XEDS and FTIR spectra, the crystal symmetry, chemical elements, and the present functional groups of the studied samples were determined and found to correspond to those reported in the literature, with a stoichiometry close to the ideal for biological applications. Additionally, by means of the photoacoustic detection and infrared photothermal radiometry (IPTR) techniques, the thermal response of the samples was obtained. Analyzing the photoacoustic data, the synthetized samples show photoacoustic opaqueness, responding in the thermally thick regime in the measurement range, and their thermal effusivity was also determined, having values of 1.47 folds the thermal effusivity of the mandibular human bone. Finally, from the IPTR measurements, the thermal diffusivity and thermal conductivity of the samples were also determined, having good agreement with the reported values for synthetic hydroxyapatite. The structural and thermophysical properties of the here reported samples show that the synthesized samples have good thermal affinity with the mandibular human bone tissue, and are suitable for biomedical applications.

  8. Differential clonal evolution in oesophageal cancers in response to neo-adjuvant chemotherapy.

    PubMed

    Findlay, John M; Castro-Giner, Francesc; Makino, Seiko; Rayner, Emily; Kartsonaki, Christiana; Cross, William; Kovac, Michal; Ulahannan, Danny; Palles, Claire; Gillies, Richard S; MacGregor, Thomas P; Church, David; Maynard, Nicholas D; Buffa, Francesca; Cazier, Jean-Baptiste; Graham, Trevor A; Wang, Lai-Mun; Sharma, Ricky A; Middleton, Mark; Tomlinson, Ian

    2016-04-05

    How chemotherapy affects carcinoma genomes is largely unknown. Here we report whole-exome and deep sequencing of 30 paired oesophageal adenocarcinomas sampled before and after neo-adjuvant chemotherapy. Most, but not all, good responders pass through genetic bottlenecks, a feature associated with higher mutation burden pre-treatment. Some poor responders pass through bottlenecks, but re-grow by the time of surgical resection, suggesting a missed therapeutic opportunity. Cancers often show major changes in driver mutation presence or frequency after treatment, owing to outgrowth persistence or loss of sub-clones, copy number changes, polyclonality and/or spatial genetic heterogeneity. Post-therapy mutation spectrum shifts are also common, particularly C>A and TT>CT changes in good responders or bottleneckers. Post-treatment samples may also acquire mutations in known cancer driver genes (for example, SF3B1, TAF1 and CCND2) that are absent from the paired pre-treatment sample. Neo-adjuvant chemotherapy can rapidly and profoundly affect the oesophageal adenocarcinoma genome. Monitoring molecular changes during treatment may be clinically useful.

  9. [Determination of arsenic speciation in Scomberomorus niphonius by capillary electrophoresis-inductively coupled plasma mass spectrometry].

    PubMed

    Chen, Fa-rong; Zheng, Li; Wang, Zhi-Guang; Sun, Jie; Han, Li-Hui; Wang, Xiao-ru

    2014-06-01

    A method for the detection of arsenocholine (AsC), arsenobetaine (AsB), As(III), dimethylarsinic (DMA), monomethylarsonic (MMA) and As (V) by capillary electrophoresis-inductively coupled plasma mass spectrometry (CE-ICP-MS) was established. The results showed that the six species of arsenic were separated within 20 min under the optimized conditions. Good linearities of 6 arsenic species were observed in the range from 2 to 50 μg x L(-1) with the linear correlation greater than 0.996, the detection limits were 0.10-1.08 μg x L(-1) and the RSDs (n = 5) of the peak areas were smaller than 7%. The method was successfully adopted to the determination of the species in Scomberomorus niphonius. The recoveries were between 93% and 98%, and we found the arsenobetaine (AsB) was the main species in the sample. The method was suitable for the analysis of other biological samples with the advantages of good stability, less sample consumption, short analysis time and convenience.

  10. Selective isolation of gonyautoxins 1,4 from the dinoflagellate Alexandrium minutum based on molecularly imprinted solid-phase extraction.

    PubMed

    Lian, Ziru; Wang, Jiangtao

    2017-09-15

    Gonyautoxins 1,4 (GTX1,4) from Alexandrium minutum samples were isolated selectively and recognized specifically by an innovative and effective extraction procedure based on molecular imprinting technology. Novel molecularly imprinted polymer microspheres (MIPMs) were prepared by double-templated imprinting strategy using caffeine and pentoxifylline as dummy templates. The synthesized polymers displayed good affinity to GTX1,4 and were applied as sorbents. Further, an off-line molecularly imprinted solid-phase extraction (MISPE) protocol was optimized and an effective approach based on the MISPE coupled with HPLC-FLD was developed for selective isolation of GTX1,4 from the cultured A. minutum samples. The separation method showed good extraction efficiency (73.2-81.5%) for GTX1,4 and efficient removal of interferences matrices was also achieved after the MISPE process for the microalgal samples. The outcome demonstrated the superiority and great potential of the MISPE procedure for direct separation of GTX1,4 from marine microalgal extracts. Copyright © 2017. Published by Elsevier Ltd.

  11. Structural and magnetic characterization of Ti doped cobalt ferrite (CoFe2O4)

    NASA Astrophysics Data System (ADS)

    Pal, Jaswinder; Kumar, Sunil; Kaur, Randeep; Agrawal, P.; Singh, Mandeep; Singh, Anupinder

    2018-05-01

    Synthesis of Co1-xTixFe2O4 solid solutions for 0.1≤x≤0.4 using the solid-state-reaction rate has been done. The prepared samples were characterized by using XRD (X-ray diffraction) and SEM (Scanning Electron Microscopy). Magnetic studies have been done using Vibrating Sample Magnetometer (VSM). XRD confirmed that Cobalt Ferrite spinel cubic structure in all prepared samples. The lattice parameter `a' increases with increase in the concentration of Ti. SEM micrograph shows good grain growth in all samples. Magnetic Study reveals that the M-H curves of all the prepared samples taken at room temperature are very well saturated. The maximum value of remnant magnetization (Mr ˜13.9 emu/g) and saturation magnetization (Ms ˜74.4 emu/g) has been observed for x =0.2 sample. Coercivity does not show any regular variation with increase in the molar concentration of Ti in CoFe2O4 at A-site.

  12. Hydrothermal Synthesized of CoMoO4 Microspheres as Excellent Electrode Material for Supercapacitor.

    PubMed

    Li, Weixia; Wang, Xianwei; Hu, Yanchun; Sun, Lingyun; Gao, Chang; Zhang, Cuicui; Liu, Han; Duan, Meng

    2018-04-24

    The single-phase CoMoO 4 was prepared via a facile hydrothermal method coupled with calcination treatment at 400 °C. The structures, morphologies, and electrochemical properties of samples with different hydrothermal reaction times were investigated. The microsphere structure, which consisted of nanoflakes, was observed in samples. The specific capacitances at 1 A g -1 are 151, 182, 243, 384, and 186 F g -1 for samples with the hydrothermal times of 1, 4, 8, 12, and 24 h, respectively. In addition, the sample with the hydrothermal time of 12 h shows a good rate capability, and there is 45% retention of initial capacitance when the current density increases from 1 to 8 A g -1 . The high retain capacitances of samples show the fine long-cycle stability after 1000 charge-discharge cycles at current density of 8 A g -1 . The results indicate that CoMoO 4 samples could be a choice of excellent electrode materials for supercapacitor.

  13. Hydrothermal Synthesized of CoMoO4 Microspheres as Excellent Electrode Material for Supercapacitor

    NASA Astrophysics Data System (ADS)

    Li, Weixia; Wang, Xianwei; Hu, Yanchun; Sun, Lingyun; Gao, Chang; Zhang, Cuicui; Liu, Han; Duan, Meng

    2018-04-01

    The single-phase CoMoO4 was prepared via a facile hydrothermal method coupled with calcination treatment at 400 °C. The structures, morphologies, and electrochemical properties of samples with different hydrothermal reaction times were investigated. The microsphere structure, which consisted of nanoflakes, was observed in samples. The specific capacitances at 1 A g-1 are 151, 182, 243, 384, and 186 F g-1 for samples with the hydrothermal times of 1, 4, 8, 12, and 24 h, respectively. In addition, the sample with the hydrothermal time of 12 h shows a good rate capability, and there is 45% retention of initial capacitance when the current density increases from 1 to 8 A g-1. The high retain capacitances of samples show the fine long-cycle stability after 1000 charge-discharge cycles at current density of 8 A g-1. The results indicate that CoMoO4 samples could be a choice of excellent electrode materials for supercapacitor.

  14. Chemical composition, cytotoxicity and in vitro antitrypanosomal and antiplasmodial activity of the essential oils of four Cymbopogon species from Benin.

    PubMed

    Kpoviessi, Salomé; Bero, Joanne; Agbani, Pierre; Gbaguidi, Fernand; Kpadonou-Kpoviessi, Bénédicta; Sinsin, Brice; Accrombessi, Georges; Frédérich, Michel; Moudachirou, Mansourou; Quetin-Leclercq, Joëlle

    2014-01-01

    Cymbopogon species are largely used in folk medicine for the treatment of many diseases some of which related to parasitical diseases as fevers and headaches. As part of our research on antiparasitic essential oils from Beninese plants, we decided to evaluate the in vitro antiplasmodial and antitrypanosomal activities of essential oils of four Cymbopogon species used in traditional medicine as well as their cytotoxicity. The essential oils of four Cymbopogon species Cymbopogon citratus (I), Cymbopogon giganteus (II), Cymbopogon nardus (III) and Cymbopogon schoenantus (IV) from Benin obtained by hydrodistillation were analysed by GC/MS and GC/FID and were tested in vitro against Trypanosoma brucei brucei and Plasmodium falciparum respectively for antitrypanosomal and antiplasmodial activities. Cytotoxicity was evaluated in vitro against Chinese Hamster Ovary (CHO) cells and the human non cancer fibroblast cell line (WI38) through MTT assay to evaluate the selectivity. All tested oils showed a strong antitrypanosomal activity with a good selectivity. Sample II was the most active against Trypanosoma brucei brucei and could be considered as a good candidate. It was less active against Plasmodium falciparum. Samples II, III and IV had low or no cytotoxicity, but the essential oil of Cymbopogon citratus (I), was toxic against CHO cells and moderately toxic against WI38 cells and needs further toxicological studies. Sample I (29 compounds) was characterised by the presence as main constituents of geranial, neral, β-pinene and cis-geraniol; sample II (53 compounds) by trans-p-mentha-1(7),8-dien-2-ol, trans-carveol, trans-p-mentha-2,8-dienol, cis-p-mentha-2,8-dienol, cis-p-mentha-1(7),8-dien-2-ol, limonene, cis-carveol and cis-carvone; sample III (28 compounds) by β-citronellal, nerol, β-citronellol, elemol and limonene and sample IV (41 compounds) by piperitone, (+)-2-carene, limonene, elemol and β-eudesmol. Our study shows that essential oils of Cymbopogon genus can be a good source of antitrypanosomal agents. This is the first report on the activity of these essential oils against Trypanosoma brucei brucei, Plasmodium falciparum and analysis of their cytotoxicity. © 2013 Published by Elsevier Ireland Ltd.

  15. Assessment of the characteristics and biocompatibility of gelatin sponge scaffolds prepared by various crosslinking methods.

    PubMed

    Yang, Gang; Xiao, Zhenghua; Long, Haiyan; Ma, Kunlong; Zhang, Junpeng; Ren, Xiaomei; Zhang, Jiang

    2018-01-25

    This comparative study aims to identify a biocompatible and effective crosslinker for preparing gelatin sponges. Glutaraldehyde (GTA), genipin (GP), 1-ethyl-3-(3-dimethyl aminopropyl)carbodiimide (EDC), and microbial transglutaminase (mTG) were used as crosslinking agents. The physical properties of the prepared samples were characterized, and material degradation was studied in vitro with various proteases and in vivo through subcutaneous implantation of the sponges in rats. Adipose-derived stromal stem cells (ADSCs) were cultured and inoculated onto the scaffolds to compare the cellular biocompatibility of the sponges. Cellular seeding efficiency and digestion time of the sponges were also evaluated. Cellular viability and proliferation in scaffolds were analyzed by fluorescence staining and MTT assay. All the samples exhibited high porosity, good swelling ratio, and hydrolysis properties; however, material strength, hydrolysis, and enzymolytic properties varied among the samples. GTA-sponge and GP-sponge possessed high compressive moduli, and EDC-sponge exhibited fast degradation performance. GTA and GP sponge implants exerted strong in vivo rejections, and the former showed poor cell growth. mTG-sponge exhibited the optimal comprehensive performance, with good porosity, compressive modulus, anti-degradation ability, and good biocompatibility. Hence, mTG-sponge can be used as a scaffold material for tissue engineering applications.

  16. Synthesis of n-type Bi4-xLaxTi3O12 (x=0 to 0.45) by alternative mechanochemical method

    NASA Astrophysics Data System (ADS)

    Sharanappa, Nagbasavanna

    2017-05-01

    Lanthanum doped bismuth titanate ceramic samples have been successfully synthesized by mechanochemical method showed good properties and have investigated the structure, microstructure, dielectric, Curie-Weiss behavior, thermoelectric properties, which resulted from substitution of La-ions in bismuth titanate. Plate-like shape with enhanced density is observed in the SEM micrographs. Ceramic samples exhibiting relaxor ferroelectric behavior by satisfying Curie-Weiss law. Thermoelectric studies reveal n-type semiconducting behavior of these samples. Synthesized compounds explored these desirable properties for innovative semiconductor based device applications.

  17. Sampling methods in archaeomagnetic dating: A comparison using case studies from Wörterberg, Eisenerz and Gams Valley (Austria)

    NASA Astrophysics Data System (ADS)

    Trapanese, A.; Batt, C. M.; Schnepp, E.

    The aim of this research was to review the relative merits of different methods of taking samples for archaeomagnetic dating. To allow different methods to be investigated, two archaeological structures and one modern fireplace were sampled in Austria. On each structure a variety of sampling methods were used: the tube and disc techniques of Clark et al. (Clark, A.J., Tarling, D.H., Noel, M., 1988. Developments in archaeomagnetic dating in Great Britain. Journal of Archaeological Science 15, 645-667), the drill core technique, the mould plastered hand block method of Thellier, and a modification of it. All samples were oriented with a magnetic compass and sun compass, where weather conditions allowed. Approximately 12 discs, tubes, drill cores or plaster hand blocks were collected from each structure, with one mould plaster hand block being collected and cut into specimens. The natural remanent magnetisation (NRM) of the samples was measured and stepwise alternating field (AF) or thermal demagnetisation was applied. Samples were measured either in the UK or in Austria, which allowed the comparison of results between magnetometers with different sensitivity. The tubes and plastered hand block specimens showed good agreement in directional results, and the samples obtained showed good stability. The discs proved to be unreliable as both NRM and the characteristic remanent magnetisation (ChRM) distribution were very scattered. The failure of some methods may be related to the suitability of the material sampled, for example if it was disturbed before sampling, had been insufficiently heated or did not contain appropriate magnetic minerals to retain a remanent magnetisation. Caution is also recommended for laboratory procedures as the cutting of poorly consolidated specimens may disturb the material and therefore the remanent magnetisation. Criteria and guidelines were established to aid researchers in selecting the most appropriate method for a particular archaeological structure.

  18. General Health Questionnaire-12 validity in Colombia and factorial equivalence between clinical and nonclinical participants.

    PubMed

    Ruiz, Francisco J; García-Beltrán, Diana M; Suárez-Falcón, Juan C

    2017-10-01

    The General Health Questionnaire - 12 (GHQ-12) is a widely used screening self-report for emotional disorders among adults. However, there is little evidence concerning the validity of the GHQ-12 in Colombia and its factorial invariance between nonclinical and clinical samples. Accordingly, the current study aims to explore the GHQ-12 validity in Colombian nonclinical and clinical samples. The GHQ-12 was administered to a total of 1641 participants, including a sample of undergraduates, one of general population, and a clinical sample. The internal consistency of the GHQ-12 across samples was good (overall alpha of .90). The one-factor model showed a good fit to the data and was considered theoretically more coherent than the two-factor model with positive and negative items loading in separate factors. Metric and scalar invariance were observed across nonclinical and clinical samples. The GHQ-12 scores were strongly and positively related to emotional symptoms and experiential avoidance, and negatively related to life satisfaction. According to the receiver operating characteristic (ROC) curves, a threshold score of 11/12 was optimal to identify emotional disorders. In conclusion, the GHQ-12 is a valid screening self-report in Colombia that provides scores that can be compared across clinical and nonclinical participants. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Gas chromatography/principal component similarity system for detection of E. coli and S. aureus contaminating salmon and hamburger.

    PubMed

    Nakai, S; Wang, Z H; Dou, J; Nakamura, S; Ogawa, M; Nakai, E; Vanderstoep, J

    1999-02-01

    Coho, Atlantic, Spring, and Sockeye salmon and five commercial samples of hamburger patties were analyzed by processing gas chromatography (GC) data of volatile compounds using the principal component similarity (PCS) technique. PCS scattergrams of the samples inoculated with Escherichia coli and Staphylococcus aureus followed by incubation showed the pattern-shift lines moving away from the data point for uninoculated, unincubated reference samples in different directions with increasing incubation time. When the PCS scattergrams were drawn for samples incubated overnight, the samples inoculated with the two bacterial species and the uninoculated samples appeared as three separated groups. This GC/PCS approach has the potential to ensure quality of samples by discriminating good samples from potentially spoiled samples. The latter may require further microbial assays to identify the bacteria species potentially contaminating foods.

  20. Magnetic N-doped mesoporous carbon as an adsorbent for the magnetic solid-phase extraction of phthalate esters from soft drinks.

    PubMed

    Li, Menghua; Jiao, Caina; Yang, Xiumin; Wang, Chun; Wu, Qiuhua; Wang, Zhi

    2017-04-01

    A new kind of magnetic N-doped mesoporous carbon was prepared by the one-step carbonization of a hybrid precursor (glucose, melamine, and iron chloride) in a N 2 atmosphere with a eutectic salt (KCl/ZnCl 2 ) as the porogen. The obtained magnetic N-doped mesoporous carbon showed excellent characteristics, such as strong magnetic response, high surface area, large pore volume, and abundant π-electron system, which endow it with a great potential as a magnetic solid-phase extraction adsorbent. To evaluate its adsorption performance, the magnetic N-doped mesoporous carbon was used for the extraction of three phthalate esters from soft drink samples followed by high-performance liquid chromatographic analysis. Under the optimum conditions, the developed method showed a good linearity (1.0-120.0 ng/mL), low limit of detection (0.1-0.3 ng/mL, S/N = 3), and good recoveries (83.2-119.0%) in soft drink samples. The results indicated that the magnetic N-doped mesoporous carbon has an excellent adsorption capacity for phthalate esters and the present method is simple, accurate, and highly efficient for the extraction and determination of phthalate esters in complex matrix samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jackson, L.L.; Engleman, E.E.; Peard, J.L.

    Sulfur was determined in plants and lichens by combustion of the sample and infrared detection of evolved sulfur dioxide using an automated sulfur analyzer. Vanadium pentaoxide was used as a combustion accelerator. Pelletization of the sample prior to combustion was not found to be advantageous. Washing studies showed that leaching of sulfur was not a major factor in the sample preparation. The combustion-IR analysis usually gave higher sulfur content than the turbidimetric analysis as well as shorter analysis time. Relative standard deviations of less than 7% were obtained by the combustion-IR technique when sulfur levels in plant material range frommore » 0.05 to 0.70%. Determination of sulfur in National Bureau of Standards botanical reference materials showed good agreement between the combustion-IR technique and other instrumental procedures. Seven NBS botanical reference materials were analyzed.« less

  2. Rapid and non-invasive analysis of deoxynivalenol in durum and common wheat by Fourier-Transform Near Infrared (FT-NIR) spectroscopy.

    PubMed

    De Girolamo, A; Lippolis, V; Nordkvist, E; Visconti, A

    2009-06-01

    Fourier transform near-infrared spectroscopy (FT-NIR) was used for rapid and non-invasive analysis of deoxynivalenol (DON) in durum and common wheat. The relevance of using ground wheat samples with a homogeneous particle size distribution to minimize measurement variations and avoid DON segregation among particles of different sizes was established. Calibration models for durum wheat, common wheat and durum + common wheat samples, with particle size <500 microm, were obtained by using partial least squares (PLS) regression with an external validation technique. Values of root mean square error of prediction (RMSEP, 306-379 microg kg(-1)) were comparable and not too far from values of root mean square error of cross-validation (RMSECV, 470-555 microg kg(-1)). Coefficients of determination (r(2)) indicated an "approximate to good" level of prediction of the DON content by FT-NIR spectroscopy in the PLS calibration models (r(2) = 0.71-0.83), and a "good" discrimination between low and high DON contents in the PLS validation models (r(2) = 0.58-0.63). A "limited to good" practical utility of the models was ascertained by range error ratio (RER) values higher than 6. A qualitative model, based on 197 calibration samples, was developed to discriminate between blank and naturally contaminated wheat samples by setting a cut-off at 300 microg kg(-1) DON to separate the two classes. The model correctly classified 69% of the 65 validation samples with most misclassified samples (16 of 20) showing DON contamination levels quite close to the cut-off level. These findings suggest that FT-NIR analysis is suitable for the determination of DON in unprocessed wheat at levels far below the maximum permitted limits set by the European Commission.

  3. Preparation of highly stable fullerene C60 decorated graphene oxide nanocomposite and its sensitive electrochemical detection of dopamine in rat brain and pharmaceutical samples.

    PubMed

    Thirumalraj, Balamurugan; Palanisamy, Selvakumar; Chen, Shen-Ming; Lou, Bih-Show

    2016-01-15

    The research community has continuously paid much attention on the preparation of hybrid of carbon nanomaterials owing to combine their unique properties. Herein, we report the preparation of highly stable fullerene C60 (C60) wrapped graphene oxide (GO) nanocomposite by using a simple sonication method. The fabricated GO-C60 nanocomposite modified glassy carbon electrode shows a good sensitivity and lower oxidation overpotential towards dopamine (DA) than that of pristine GO and C60. The fabricated sensor detects the DA in the linear response range of 0.02-73.5μM. The limit of detection is estimated to be 0.008μM based on 3σ with a sensitivity of 4.23μAμM(-1)cm(-2). The fabricated sensor also exhibits other features such as good selectivity, stability, reproducibility and repeatability. The proposed sensor exhibits good practicality towards the detection of DA in rat brain and commercial DA injection samples. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Good and Bad Sleep in Childhood: A Questionnaire Survey amongst School Children in Southern Italy.

    PubMed

    Ficca, Gianluca; Conte, Francesca; De Padova, Vittoria; Zilli, Iole

    2011-01-01

    Despite its clinical importance, the issue of subjective sleep quality in children remains unexplored. Here we investigate, in school-aged children, the prevalence of bad sleep perception and its relationships with sleep habits and daytime functioning, to provide hints on its possible determinants. Subjective sleep perception, sleep habits, and daytime functioning were studied through a questionnaire survey in a sample of 482 children (6-12 yrs.). Being "bad sleeper" was reported by 6.9% of the sample. Compared to the "good sleepers", these subjects displayed shorter sleep duration on schooldays, longer sleep latencies, and a more pronounced evening preference, beyond more frequent insufficient sleep. Though no differences emerged in sleepiness, bad sleepers showed higher impairments in daytime functioning, indicated by more frequent depressed mood and impulsivity. These distinctive features might be very important to precociously detect those children who are possibly more vulnerable to sleep disturbances and whose sleep-wake rhythms evolution should be paid particular attention thereafter. "The good people sleep much better at night than the bad people.Of course, the bad people enjoy the waking hours much more"Woody Allen.

  5. Development of a Chinese Version of the Suicide Intent Scale

    ERIC Educational Resources Information Center

    Gau, Susan S. F.; Chen, Chin-Hung; Lee, Charles T. C.; Chang, Jung-Chen; Cheng, Andrew T. A.

    2009-01-01

    This study established the psychometric properties of the Chinese version of the Suicide Intent Scale (SIS) in a clinic- and community-based sample of 36 patients and 592 respondents, respectively. Results showed that the Chinese SIS demonstrated good inter-rater and test-retest reliability. Factor analysis generated three factors (Precautions,…

  6. Estimating population genetic parameters and comparing model goodness-of-fit using DNA sequences with error

    PubMed Central

    Liu, Xiaoming; Fu, Yun-Xin; Maxwell, Taylor J.; Boerwinkle, Eric

    2010-01-01

    It is known that sequencing error can bias estimation of evolutionary or population genetic parameters. This problem is more prominent in deep resequencing studies because of their large sample size n, and a higher probability of error at each nucleotide site. We propose a new method based on the composite likelihood of the observed SNP configurations to infer population mutation rate θ = 4Neμ, population exponential growth rate R, and error rate ɛ, simultaneously. Using simulation, we show the combined effects of the parameters, θ, n, ɛ, and R on the accuracy of parameter estimation. We compared our maximum composite likelihood estimator (MCLE) of θ with other θ estimators that take into account the error. The results show the MCLE performs well when the sample size is large or the error rate is high. Using parametric bootstrap, composite likelihood can also be used as a statistic for testing the model goodness-of-fit of the observed DNA sequences. The MCLE method is applied to sequence data on the ANGPTL4 gene in 1832 African American and 1045 European American individuals. PMID:19952140

  7. Liquid chromatography-tandem mass spectrometry for the quantification of flurbiprofen in human plasma and its application in a study of bioequivalence.

    PubMed

    Mei, Chenghan; Li, Bin; Yin, Qiangfeng; Jin, Jing; Xiong, Ting; He, Wenjuan; Gao, Xiujuan; Xu, Rong; Zhou, Piqi; Zheng, Heng; Chen, Hui

    2015-07-01

    A simple, quick and accurate LC-MS/MS method for the quantification of flurbiprofen in human plasma with indomethacin as internal standard (IS) was developed and validated. Samples were treated with methanol to precipitate proteins, then separated on a Ultimate C18 column (5μm, 2.1×50mm) with a gradient elusion process. Mobile phase A was comprised of water and formic acid, mobile phase B was comprised of acetonitrile and formic acid. Multi reaction monitoring (MRM) signals were saved on a negative ionization electrospray mass spectrometer. The calibration curve showed good linearity in the range of 40.00-10000.00μg/L (r(2)=0.998). Intra-day RE was 0.2-2.2%. Inter-day RE was 0.5-3.4%. The samples showed good stability under the study conditions. No significant matrix effect was observed. The established method was then applied to a bioequivalence study of a flurbiprofen axetil formulation. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Solar Occultation Satellite Data and Derived Meteorological Products: Sampling Issues and Comparisons with Aura MLS

    NASA Technical Reports Server (NTRS)

    Manney, Gloria; Daffer, William H.; Zawodny, Joseph M.; Bernath, Peter F.; Hoppel, Karl W.; Walker, Kaley A.; Knosp, Brian W.; Boone, Chris; Remsberg, Ellis E.; Santee, Michelle L.; hide

    2007-01-01

    Derived Meteorological Products (DMPs, including potential temperature (theta), potential vorticity, equivalent latitude (EqL), horizontal winds and tropopause locations) have been produced for the locations and times of measurements by several solar occultation (SO) instruments and the Aura Microwave Limb Sounder (MLS). DMPs are calculated from several meteorological analyses for the Atmospheric Chemistry Experiment-Fourier Transform Spectrometer, Stratospheric Aerosol and Gas Experiment II and III, Halogen Occultation Experiment, and Polar Ozone and Aerosol Measurement II and III SO instruments and MLS. Time-series comparisons of MLS version 1.5 and SO data using DMPs show good qualitative agreement in time evolution of O3, N2O, H20, CO, HNO3, HCl and temperature; quantitative agreement is good in most cases. EqL-coordinate comparisons of MLS version 2.2 and SO data show good quantitative agreement throughout the stratosphere for most of these species, with significant biases for a few species in localized regions. Comparisons in EqL coordinates of MLS and SO data, and of SO data with geographically coincident MLS data provide insight into where and how sampling effects are important in interpretation of the sparse SO data, thus assisting in fully utilizing the SO data in scientific studies and comparisons with other sparse datasets. The DMPs are valuable for scientific studies and to facilitate validation of non-coincident measurements.

  9. Water quality in Atlantic rainforest mountain rivers (South America): quality indices assessment, nutrients distribution, and consumption effect.

    PubMed

    Avigliano, Esteban; Schenone, Nahuel

    2016-08-01

    The South American Atlantic rainforest is a one-of-a-kind ecosystem considered as a biodiversity hotspot; however, in the last decades, it was intensively reduced to 7 % of its original surface. Water resources and water quality are one of the main goods and services this system provides to people. For monitoring and management recommendations, the present study is focused on (1) determining the nutrient content (nitrate, nitrite, ammonium, and phosphate) and physiochemical parameters (temperature, pH, electrical conductivity, turbidity, dissolved oxygen, and total dissolved solids) in surface water from 24 rainforest mountain rivers in Argentina, (2) analyzing the human health risk, (3) assessing the environmental distribution of the determined pollutants, and (4) analyzing water quality indices (WQIobj and WQImin). In addition, for total coliform bacteria, a dataset was used from literature. Turbidity, total dissolved solids, and nitrite (NO2 (-)) exceeded the guideline value recommended by national or international guidelines in several sampling stations. The spatial distribution pattern was analyzed by Principal Component Analysis and Factor Analysis (PCA/FA) showing well-defined groups of rivers. Both WQI showed good adjustment (R (2) = 0.89) and rated water quality as good or excellent in all sampling sites (WQI > 71). Therefore, this study suggests the use of the WQImin for monitoring water quality in the region and also the water treatment of coliform, total dissolved solids, and turbidity.

  10. Application of methyl silane coated iron oxide magnetic nanoparticles for solid-phase extraction and determination of fat-soluble vitamins by high performance liquid chromatography.

    PubMed

    Momenbeik, Fariborz; Yazdani, Elham

    2015-01-01

    Methyl silane coated Fe3O4 magnetic nanoparticles were used for simultaneous extraction of the fat-soluble vitamins (FSVs). The amounts of extracted vitamins were determined by HPLC. The synthesized Fe3O4 nanoparticles were coated with silica and then modified with trimethoxymethylsilane (TMMS). The prepared particles were characterized by different methods. The best amounts of silica and TMMS in sorbent synthesis were 1.2 and 0.5 mL, respectively. The optimum pH values for the sample solution and washing buffer were 5 and 3, respectively. Application of 100 mg sorbent, 700 μL tetrahydrofuran, 5-fold dilution of the sample solution, and 1 min for sorption and desorption times were among the best conditions. At the optimum conditions, the calibration plots for each vitamin were obtained with good linearity (R(2) >0.9992) and suitable linear ranges. This method has a low LOD (<76.1 μg/mL), acceptable repeatability (RSD <5.63%) and reproducibility (RSD <4.71%), and good accuracy (recovery >90.3%). Preconcentration of low concentrations of vitamin D3 was performed, and results showed 3.7 times greater sensitivity after preconcentration. Finally, the amounts of the FSVs in pharmaceutical formulations were determined using the proposed method, and results showed good agreement with those reported by manufacturers.

  11. Development and validation of an attributional style questionnaire for adolescents.

    PubMed

    Rodríguez-Naranjo, Carmen; Caño, Antonio

    2010-12-01

    We describe the development and psychometric characteristics of a new version of the Attributional Style Questionnaire (ASQ; Seligman, Abramson, Semmell, & Von Baeyer, 1979)--a version called the Attributional Style Questionnaire for Adolescents (ASQ-A)--using 3 samples (Ns = 547, 438, and 240) of Spanish secondary school students. In Study 1, the initial pool of 87 items was reduced to 54. Study 2 further analyzed the 54 scale items and revealed that the Internality, Stability, and Globality subscale scores had good reliability, good factorial construct validity, and satisfactory associations with maladaptive mood ratings. In Study 3, the regression analyses showed good and specific predictive validities of ASQ-A subscales for the attributions that the adolescents made about a particular real-life stressful situation. Study 4 showed that over an 8-month period the changes in the Stability and Globality subscales depended on the intensity of stressful life events experienced in this period. Overall, the studies revealed that the new ASQ-A served as an appropriate instrument to assess attributional style in adolescents.

  12. Psychometric properties of the Sexual Excitation/Sexual Inhibition Inventory for Women and Men (SESII-W/M) and the Sexual Excitation Scales/Sexual Inhibition Scales short form (SIS/SES-SF) in a population-based sample in Germany

    PubMed Central

    Scholten, Saskia; Margraf, Jürgen

    2018-01-01

    The Sexual Excitation Sexual/Inhibition Inventory for Women and Men (SESII-W/M) and the Sexual Excitation Scales/Sexual Inhibition Scales short form (SIS/SES-SF) are two self-report questionnaires for assessing sexual excitation (SE) and sexual inhibition (SI). According to the dual control model of sexual response, SE and SI differ between individuals and influence the occurrence of sexual arousal in given situations. Extreme levels of SE and SI are postulated to be associated with sexual difficulties or risky sexual behaviors. The present study was designed to assess the psychometric properties of the German versions of both questionnaires utilizing a large population-based sample of 2,708 participants (Mage = 51.19, SD = 14.03). Overall, psychometric evaluation of the two instruments yielded good convergent and discriminant validity and mediocre to good internal consistency. The original 30-item version of the SESII-W/M did not show a sufficient model fit. For a 24-item version of the SESII-W/M partial strong measurement invariance across gender, and strong measurement invariance across relationship status, age, and educational levels were established. The original structure (14 items, 3 factors) of the SIS/SES-SF was not replicated. However, a 4-factor model including 13 items showed a good model fit and strong measurement invariance across the before-mentioned participant groups. For both questionnaires, partial strong measurement invariance with the original American versions of the scales was found. As some factors showed unsatisfactory internal consistency and the factor structure of the original scales could not be replicated, scores on several SE- and SI-factors should be interpreted with caution. However, most analyses indicated sufficient psychometric quality of the German SESII-W/M and SIS/SES-SF and their use can be recommended in German-speaking samples. More research with diverse samples (i.e., different sexual orientations, individuals with sexual difficulties) is needed to ensure the replicability of the factor solutions presented in this study. PMID:29529045

  13. Design and Field Procedures in the US National Comorbidity Survey Replication Adolescent Supplement (NCS-A)

    PubMed Central

    Kessler, Ronald C.; Avenevoli, Shelli; Costello, E. Jane; Green, Jennifer Greif; Gruber, Michael J.; Heeringa, Steven; Merikangas, Kathleen R.; Pennell, Beth-Ellen; Sampson, Nancy A.; Zaslavsky, Alan M.

    2009-01-01

    An overview is presented of the design and field procedures of the US National Comorbidity Survey Replication Adolescent Supplement (NCS-A), a US face-to-face household survey of the prevalence and correlates of DSM-IV mental disorders. The survey was based on a dual-frame design that included 904 adolescent residents of the households that participated in the US National Comorbidity Survey Replication (85.9% response rate) and 9,244 adolescent students selected from a nationally representative sample of 320 schools (74.7% response rate). After expositing the logic of dual-frame designs, comparisons are presented of sample and population distributions on Census socio-demographic variables and, in the school sample, school characteristics. These document only minor differences between the samples and the population. The results of statistical analysis of the bias-efficiency trade-off in weight trimming are then presented. These show that modest trimming meaningfully reduces mean squared error. Analysis of comparative sample efficiency shows that the household sample is more efficient than the school sample, leading to the household sample getting a higher weight relative to its size in the consolidated sample relative to the school sample. Taken together, these results show that the NCS-A is an efficient sample of the target population with good representativeness on a range of socio-demographic and geographic variables. PMID:19507169

  14. Genotypes and enterotoxicity of Staphylococcus aureus isolated from the hands and nasal cavities of flight-catering employees.

    PubMed

    Hatakka, M; Björkroth, K J; Asplund, K; Mäki-Petäys, N; Korkeala, H J

    2000-11-01

    Hand and nasal samples of flight-catering staff were collected from 1995 to 1997 to find employees carrying Staphylococcus aureus. Altogether 153 hand samples and 136 nose samples were taken. Nasal sampling showed a higher prevalence of S. aureus among food handlers (29%) than hand sampling (9%). A high proportion of the strains (46%) were enterotoxigenic, and a considerable amount of food handlers carried enterotoxigenic S. aureus, 6% and 12% according to hand and nasal sampling, respectively. Pulsed-field gel electrophoresis macrorestriction profiles revealed a total of 32 different types associated with the 35 employees carrying S. aureus. In most cases, the same type colonized both the hand and nose of a person. Despite the wide variety of types found, one strain colonized five persons and the second most common strain was associated with four food handlers. The predominant toxin produced was B, which was produced by the most common strain. The results showed that nasal sampling is a good way to detect S. aureus carriers, whereas hand sampling may fail to reveal carriers. The high proportion of enterotoxigenic strains show that a food handler harboring S. aureus must be considered a potential source of enterotoxigenic strains for airline meals.

  15. Psychometric properties of the Chinese version of the attitudes towards cardiopulmonary resuscitation with defibrillation (ACPRD-C) among female hospital nurses in Taiwan.

    PubMed

    Lin, Hsing-Long; Lin, Mei-Hsiang; Ho, Chao-Chung; Fu, Chin-Hua; Koo, Malcolm

    2017-07-01

    Nurses are often the first responders to in-hospital cardiac emergencies. A positive attitude towards cardiopulmonary resuscitation with defibrillation may contribute to early cardiopulmonary resuscitation and rapid defibrillation, which are associated with enhanced long-term survival. The aim of this study was to translate and adapt the 31-item attitudes towards cardiopulmonary resuscitation with defibrillation and the national resuscitation guidelines (ACPRD) instrument into Chinese and to evaluate its psychometric properties in a sample of Taiwanese hospital nurses. The ACPRD instrument was translated into Chinese using professional translation services. Content validity index based on five experts to refine the translated instrument. The final instrument was applied to a sample of 290 female nurses, recruited from a regional hospital in southern Taiwan, to assess its internal consistency, factor structure, and discriminative validity. The Chinese ACPRD instrument showed good internal consistency (Cronbach's alpha=0.87). Seven factors emerged from the factor analysis. The instrument showed good discriminative validity and were able to differentiate the attitudes of nurses with more experience of defibrillation or cardiopulmonary resuscitation from those with less experience. Nurses working in emergency ward or intensive care unit also showed significantly higher overall scores compared to those working in other units. The Chinese ACPRD demonstrated adequate content validity, internal consistency, sensible factor structure, and good discriminative validity. Among Chinese-speaking nurses, it may be used as a tool for assessing the effectiveness of educational programs that aim to improve their confidence in performing cardiopulmonary resuscitation with defibrillation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. A bioinspired polydopamine approach toward the preparation of gold-modified magnetic nanoparticles for the magnetic solid-phase extraction of steroids in multiple samples.

    PubMed

    An, Xuehan; Chai, Weibo; Deng, Xiaojuan; Chen, Hui; Ding, Guosheng

    2018-05-02

    In this work, a simple, facile, and sensitive magnetic solid-phase extraction method was developed for the extraction and enrichment of three representative steroid hormones before high-performance liquid chromatography analysis. Gold-modified Fe 3 O 4 nanoparticles, as novel magnetic adsorbents, were prepared by a rapid and environmentally friendly procedure in which polydopamine served as the reductant as well as the stabilizer for the gold nanoparticles, thus successfully avoiding the use of some toxic reagents. To obtain maximum extraction efficiency, several significant factors affecting the preconcentration steps, including the amount of adsorbent, extraction time, pH of the sample solution, and the desorption conditions, were optimized, and the enrichment factors for three steroids were all higher than 90. The validity of the established method was evaluated and good analytical characteristics were obtained. A wide linearity range (0.8-500 μg/L for all the analytes) was attained with good correlation (R 2  ≥ 0.991). The low limits of detection were 0.20-0.25 μg/L, and the relative standard deviations ranged from 0.83 to 4.63%, demonstrating a good precision. The proposed method was also successfully applied to the extraction and analysis of steroids in urine, milk, and water samples with satisfactory results, which showed its reliability and feasibility in real sample analysis. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Acetylcholinesterase Immobilized on Magnetic Beads for Pesticides Detection: Application to Olive Oil Analysis

    PubMed Central

    Ben Oujji, Najwa; Bakas, Idriss; Istamboulié, Georges; Ait-Ichou, Ihya; Ait-Addi, Elhabib; Rouillon, Régis; Noguer, Thierry

    2012-01-01

    This work presents the development of bioassays and biosensors for the detection of insecticides widely used in the treatment of olive trees. The systems are based on the covalent immobilisation of acetylcholinesterase on magnetic microbeads using either colorimetry or amperometry as detection technique. The magnetic beads were immobilised on screen-printed electrodes or microtitration plates and tested using standard solutions and real samples. The developed devices showed good analytical performances with limits of detection much lower than the maximum residue limit tolerated by international regulations, as well as a good reproducibility and stability. PMID:22969377

  18. Analysis of regional-scale vegetation dynamics of Mexico using stratified AVHRR NDVI data. [Normalized Difference Vegetaion Index

    NASA Technical Reports Server (NTRS)

    Turcotte, Kevin M.; Kramber, William J.; Venugopal, Gopalan; Lulla, Kamlesh

    1989-01-01

    Previous studies have shown that a good relationship exists between AVHRR Normalized Difference Vegetation Index (NDVI) measurements, and both regional-scale patterns of vegetation seasonality and productivity. Most of these studies used known samples of vegetation types. An alternative approach, and the objective was to examine the above relationships by analyzing one year of AVHRR NDVI data that was stratified using a small-scale vegetation map of Mexico. The results show that there is a good relationship between AVHRR NDVI measurements and regional-scale vegetation dynamics of Mexico.

  19. Development and validation of NIR-chemometric methods for chemical and pharmaceutical characterization of meloxicam tablets.

    PubMed

    Tomuta, Ioan; Iovanov, Rares; Bodoki, Ede; Vonica, Loredana

    2014-04-01

    Near-Infrared (NIR) spectroscopy is an important component of a Process Analytical Technology (PAT) toolbox and is a key technology for enabling the rapid analysis of pharmaceutical tablets. The aim of this research work was to develop and validate NIR-chemometric methods not only for the determination of active pharmaceutical ingredients content but also pharmaceutical properties (crushing strength, disintegration time) of meloxicam tablets. The development of the method for active content assay was performed on samples corresponding to 80%, 90%, 100%, 110% and 120% of meloxicam content and the development of the methods for pharmaceutical characterization was performed on samples prepared at seven different compression forces (ranging from 7 to 45 kN) using NIR transmission spectra of intact tablets and PLS as a regression method. The results show that the developed methods have good trueness, precision and accuracy and are appropriate for direct active content assay in tablets (ranging from 12 to 18 mg/tablet) and also for predicting crushing strength and disintegration time of intact meloxicam tablets. The comparative data show that the proposed methods are in good agreement with the reference methods currently used for the characterization of meloxicam tablets (HPLC-UV methods for the assay and European Pharmacopeia methods for determining the crushing strength and disintegration time). The results show the possibility to predict both chemical properties (active content) and physical/pharmaceutical properties (crushing strength and disintegration time) directly, without any sample preparation, from the same NIR transmission spectrum of meloxicam tablets.

  20. Single hair analysis of small molecules using MALDI-triple quadrupole MS imaging and LC-MS/MS: investigations on opportunities and pitfalls.

    PubMed

    Poetzsch, Michael; Steuer, Andrea E; Roemmelt, Andreas T; Baumgartner, Markus R; Kraemer, Thomas

    2014-12-02

    Single hair analysis normally requires extensive sample preparation microscale protocols including time-consuming steps like segmentation and extraction. Matrix assisted laser desorption and ionization mass spectrometric imaging (MALDI-MSI) was shown to be an alternative tool in single hair analysis, but still, questions remain. Therefore, an investigation of MALDI-MSI in single hair analysis concerning the extraction process, usage of internal standard (IS), and influences on the ionization processes were systematically investigated to enable the reliable application to hair analysis. Furthermore, single dose detection, quantitative correlation to a single hair, and hair strand LC-MS/MS results were performed, and the performance was compared to LC-MS/MS single hair monitoring. The MALDI process was shown to be independent from natural hair color and not influenced by the presence of melanin. Ionization was shown to be reproducible along and in between different hair samples. MALDI image intensities in single hair and hair snippets showed good semiquantitative correlation to zolpidem hair concentrations obtained from validated routine LC-MS/MS methods. MALDI-MSI is superior to LC-MS/MS analysis when a fast, easy, and cheap sample preparation is necessary, whereas LC-MS/MS showed higher sensitivity with the ability of single dose detection for zolpidem. MALDI-MSI and LC-MS/MS segmental single hair analysis showed good correlation, and both are suitable for consumption monitoring of drugs of abuse with a high time resolution.

  1. Development of a bar adsorptive micro-extraction-large-volume injection-gas chromatography-mass spectrometric method for pharmaceuticals and personal care products in environmental water matrices.

    PubMed

    Neng, N R; Nogueira, J M F

    2012-01-01

    The combination of bar adsorptive micro-extraction using activated carbon (AC) and polystyrene-divinylbenzene copolymer (PS-DVB) sorbent phases, followed by liquid desorption and large-volume injection gas chromatography coupled to mass spectrometry, under selected ion monitoring mode acquisition, was developed for the first time to monitor pharmaceutical and personal care products (PPCPs) in environmental water matrices. Assays performed on 25 mL water samples spiked (100 ng L(-1)) with caffeine, gemfibrozil, triclosan, propranolol, carbamazepine and diazepam, selected as model compounds, yielded recoveries ranging from 74% to 99% under optimised experimental conditions (equilibrium time, 16 h (1,000 rpm); matrix characteristics: pH 5, 5% NaCl for AC phase; LD: methanol/acetonitrile (1:1), 45 min). The analytical performance showed good precision (RSD < 18%), convenient detection limits (5-20 ng L(-1)) and excellent linear dynamic range (20-800 ng L(-1)) with remarkable determination coefficients (r(2) > 0.99), where the PS-DVB sorbent phase showed a much better efficiency. By using the standard addition methodology, the application of the present analytical approach on tap, ground, sea, estuary and wastewater samples allowed very good performance at the trace level. The proposed method proved to be a suitable sorption-based micro-extraction alternative for the analysis of priority pollutants with medium-polar to polar characteristics, showing to be easy to implement, reliable, sensitive and requiring a low sample volume to monitor PPCPs in water matrices.

  2. Enhancement for trace analysis of sulfonamide antibiotics in water matrices using bar adsorptive microextraction (BAμE).

    PubMed

    Ide, A H; Ahmad, S M; Neng, N R; Nogueira, J M F

    2016-09-10

    In this study, the enhancement for trace analysis of sulfonamide antibiotics (sulfathiazole, sulfamethoxazole and sulfadimethoxine) and trimethoprim in water matrices is proposed using bar adsorptive microextraction combined with micro-liquid desorption followed by high-performance liquid chromatography with diode array detection (BAμE-μLD/HPLC-DAD). By comparing different polymers and activated carbons as sorbent coatings for BAμE, the polystyrene-divinylbenzene polymer (PS-DVB) showed the best selectivity for the compounds under study. Assays performed through BAμE(PS-DVB)-μLD on 25mL of ultrapure water samples spiked at the 8.0μgL(-1) level showed recoveries ranging from 63.8±1.5% to 84.2±1.9%, under optimized experimental conditions. The validated method provided satisfactory limits of detection (0.08-0.16μgL(-1)) and good linear dynamic ranges (0.16-8.00μgL(-1)) with determination coefficients higher than 0.9958. The proposed analytical methodology was applied to real matrices, such as tap, estuarine and wastewater samples using the standard addition method. It showed to be easy to implement, with good reproducibility, sensitivity and requiring small amount of sample. Furthermore, negligible consumption of organic solvents was used in compliance with the green analytical chemistry principles. When compared to other well-established microextraction approaches, BAμE demonstrated better performance concerning recovery yields and sensitivity. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Phase, microstructure and hydrogen storage properties of Mg-Ni materials synthesized from metal nanoparticles.

    PubMed

    Shao, Huaiyu; Chen, Chunguang; Liu, Tong; Li, Xingguo

    2014-04-04

    After Mg and Ni nanoparticles were fabricated by hydrogen plasma metal reaction, Mg-rich MgxNi₁₀₀₋x(75 < x < 90) materials were synthesized from these metal nanoparticles to study the synergistic effects for hydrogen storage in these samples to show both good kinetics and high capacity. These MgxNi₁₀₀₋x materials may absorb hydrogen with a capacity of around 3.3-5.1 wt% in 1 min at 573 K. The Mg₉₀Ni₁₀ sample shows a hydrogen capacity of 6.1 wt%. The significant kinetic enhancement is thought to be due to the unique nanostructure from the special synthesis route, the catalytic effect of the Mg₂Ni nano phase, and the synergistic effects between the Mg₂Ni and Mg phases in the materials. An interesting phenomenon which has never been reported before was observed during pressure composition isotherm (PCT) measurements. One steep step in the absorption process and two obviously separated steps in the desorption process during PCT measurements of Mg₈₀Ni₂₀ and Mg₉₀Ni₁₀ samples were observed and a possible reason from the kinetic performance of the Mg₂Ni and Mg phases in absorption and desorption processes was explained. These MgxNi₁₀₀₋x materials synthesized from Mg and Ni nanoparticles show high capacity and good kinetics, which makes these materials very promising candidates for thermal storage or energy storage and utilization for renewable power.

  4. Determination of steroid sex hormones in water and urine matrices by stir bar sorptive extraction and liquid chromatography with diode array detection.

    PubMed

    Almeida, C; Nogueira, J M F

    2006-06-16

    In this study, stir bar sorptive extraction and liquid desorption followed by high performance liquid chromatography with diode array detection (SBSE-LD-HPLC/DAD) were combined for the simultaneous determination of nine steroid sex hormones (estrone, 17alpha-estradiol, 17beta-estradiol, 17alpha-ethynylestradiol, diethylstilbestrol, mestranol, progesterone, 19-norethisterone and norgestrel) in water and urine matrices. During the method development, it has been demonstrated that equilibrium time, ionic strength and back extraction solvents are the most important parameters to control, for determining the nine-hormones in water matrices, in which stir bars coated with 126 microl of polydimethylsiloxane were used. Assays performed on 30 ml water samples spiked at 10 microg/l levels under optimised experimental conditions, yielded recoveries ranging from 11.1+/-4.9% (17beta-estradiol) to 100.2+/-10.4% (mestranol), showed that the methodology is well described by the octanol-water partition coefficients (K(PDMS/W) approximately K(O/W)) for the latter, while pronounced deviations to the theoretical efficiency (K(PDMS/W) not equal K(O/W)) were observed for the remaining hormones. From calibration studies, a good analytical performance for all hormones was attained, including a suitable precision (2.1-17.1%), low limits of detection (0.3-1.0 microg/l) and an excellent linear dynamic range (1.25-50.0 microg/l). Assays on environmental water and urine matrices showed recovery yields in worthy good agreement with the spiking level (10 microg/l), and suitability for profiling low microg/l levels of natural hormones in urine samples taken from pregnant women. The present methodology is easy, reliable and sensitive at the trace level, only requiring a low sample volume, showing to be a good analytical alternative to routine quality control for environmental and biomedical laboratories.

  5. Glyoxal and methylglyoxal in Atlantic seawater and marine aerosol particles: method development and first application during the Polarstern cruise ANT XXVII/4

    NASA Astrophysics Data System (ADS)

    van Pinxteren, M.; Herrmann, H.

    2013-06-01

    An analytical method for the determination of the alpha dicarbonyls glyoxal (GLY) and methylglyoxal (MGLY) from seawater and marine aerosol samples is presented. The method is based on derivatisation with o-(2,3,4,5,6-Pentafluorobenzyl)-hydroxylamine (PFBHA) reagent, solvent extraction and GC-MS (SIM) analysis. The method showed good precision (RSD <10%), sensitivity (detection limits in the low ng L-1 range), and accuracy (good agreement between external calibration and standard addition). The method was applied to determine GLY and MGLY in oceanic water sampled during the POLARSTERN cruise ANT XXVII/4 from Capetown to Bremerhaven in spring 2011. GLY and MGLY were determined in the sea surface microlayer (SML) of the ocean and corresponding bulkwater (BW) with average concentrations of 228 ng L-1 (GLY) and 196 ng L-1 (MGLY). The results show a significant enrichment (factor of 4) of GLY and MGLY in the SML. Furthermore, marine aerosol particles (PM1) were sampled during the cruise and analyzed for GLY (average concentration 0.19 ng m-3) and MGLY (average concentration 0.15 ng m-3). On aerosol particles, both carbonyls show a very good correlation with oxalate, supporting the idea of a secondary formation of oxalic acid via GLY and MGLY. Concentrations of GLY and MGLY in seawater and on aerosol particles were correlated to environmental parameters such as global radiation, temperature, distance to the coastline and biological activity. There are slight hints for a photochemical production of GLY and MGLY in the SML (significant enrichment in the SML, higher enrichment at higher temperature). However, a clear connection of GLY and MGLY to global radiation as well as to biological activity cannot be concluded from the data. A slight correlation between GLY and MGLY in the SML and in aerosols could be a hint for interactions of especially GLY between seawater and the atmosphere.

  6. [Influence of sample surface roughness on mathematical model of NIR quantitative analysis of wood density].

    PubMed

    Huang, An-Min; Fei, Ben-Hua; Jiang, Ze-Hui; Hse, Chung-Yun

    2007-09-01

    Near infrared spectroscopy is widely used as a quantitative method, and the main multivariate techniques consist of regression methods used to build prediction models, however, the accuracy of analysis results will be affected by many factors. In the present paper, the influence of different sample roughness on the mathematical model of NIR quantitative analysis of wood density was studied. The result of experiments showed that if the roughness of predicted samples was consistent with that of calibrated samples, the result was good, otherwise the error would be much higher. The roughness-mixed model was more flexible and adaptable to different sample roughness. The prediction ability of the roughness-mixed model was much better than that of the single-roughness model.

  7. Influence of processing conditions on point defects and luminescence centers in ZnO

    NASA Astrophysics Data System (ADS)

    Zhong, J.; Kitai, A. H.; Mascher, P.

    1993-12-01

    Positron lifetime spectroscopy and cathodoluminescence were employed to study luminescence centers in ZnO. The samples were high-purity polycrystalline ceramics sintered at temperatures ranging from 800 to 1400 C for 2 to 40 h. Scanning electron microscopy shows that as annealing temperatures and/or times increase, the average grain size increases and can reach 30 micron for samples sintered at 1200 C. At the same time, the positron bulk lifetime approaches theoretically estimated single-crystal values, while the integrated luminescence intensity increase significantly. A further increase of the sintering temperature beyond 1200 C results in a decrease in the luminescence intensity, in good agreement with the only weak luminescence observed in single-crystalline material. The positron lifetime spectra clearly show the existence of the dominant vacancy-type defect, most likely a complex involving V(sub Zn), or the divacancy, V(sub Zn)V(sub O), independent of sample thermal history. The concentration of this center steadily decreases with increasing sintering temperatures. It is concluded that the yellow luminescence centers are related to charged zinc vacancies trapped in the grain boundary regions. We propose that the observed broadness of the spectra likely originates from the modification of the electronic configuration of the luminescence centers due to their complex environment. A direct connection between the positron and the luminescence results could not be established; instead, they appear to reflect two relatively independent aspects of the samples. It could be shown, however, that positron annihilation measurements can be used effectively to monitor the evolution of the microstructure of the samples, in good agreement with scanning electron micrographs.

  8. Diagnostic accuracy of the InBiOS AMD rapid diagnostic test for the detection of Burkholderia pseudomallei antigen in grown blood culture broth.

    PubMed

    Peeters, Marjan; Chung, Panha; Lin, Hua; Mortelmans, Kristien; Phe, Chhundy; San, Chentha; Kuijpers, Laura Maria Francisca; Teav, Syna; Phe, Thong; Jacobs, Jan

    2018-06-01

    To assess the diagnostic and operational performance of the InBiOS AMD rapid diagnostic test (RDT) (Seattle, USA) for the detection of B. pseudomallei in grown blood culture broth. The InBiOS RDT is a lateral flow immunoassay in a strip format detecting B. pseudomallei capsular polysaccharide in culture fluids, marketed for research only. Broth of blood culture bottles (BacT/Alert, bioMérieux, Marcy L'Etoile, France) sampled in adult patients at the Sihanouk Hospital Center of HOPE, Phnom Penh, Cambodia, during 2010-2017 and stored at - 80 °C was tested. They included samples grown with B. pseudomallei (n = 114), samples with no growth (n = 12), and samples with growth of other pathogens (n = 139, among which Burkholderia cepacia (n = 5)). Diagnostic sensitivity and specificity were 96.5% [95% confidence interval (CI): 91.3-98.6%] and 100% [CI: 97.5-100%] respectively. Background clearance and line intensities were good and very good. The RDT's test strip, not housed in a cassette, caused difficulties in manipulation and biosafety. The centrifugation step prescribed by the procedure challenged biosafety, but processing of 19 B. pseudomallei samples without centrifugation showed similar results for line intensity and background clearance, compared to centrifugation. The InBiOS RDT showed excellent accuracy for detection of B. pseudomallei in grown blood culture broth. Provided operational adaptations such as cassette housing, it has the potential to reduce time to diagnosis of melioidosis.

  9. Investigation of xFe2O4 (x = Mn, Co) doped hydroxylapatite ferromagnetic biomaterials for the treatment of damaged bone and magnetically targeted drug delivery systems

    NASA Astrophysics Data System (ADS)

    Anand, Vikas; Singh, K. J.; Kaur, Kulwinder; Bhatia, Gaurav

    2016-05-01

    Magnetically attracted MnFe2O4 and CoFe2O4 doped hydroxylapatite samples have been prepared by using co-precipitation method in the laboratory. Bioactive nature of samples has been confirmed from XRD spectra. Ferromagnetic behavior of samples has been studied by using vibration sample magnetometer. Human osteoblast cell line MG63 has been used to explore the cell viability of samples. Drug carrier ability of samples has been checked with gentamycin as an antibiotic and results show that samples can be used as excellent drug carriers. Drug loaded samples can be easily targeted to specific area due to their attractive nature towards external magnetic field. Our results indicate that prepared samples possess good bioactive as well as ferromagnetic behavior with drug carrier ability and hence, our samples can be potential candidates for the clinical applications.

  10. Conservative Sample Size Determination for Repeated Measures Analysis of Covariance.

    PubMed

    Morgan, Timothy M; Case, L Douglas

    2013-07-05

    In the design of a randomized clinical trial with one pre and multiple post randomized assessments of the outcome variable, one needs to account for the repeated measures in determining the appropriate sample size. Unfortunately, one seldom has a good estimate of the variance of the outcome measure, let alone the correlations among the measurements over time. We show how sample sizes can be calculated by making conservative assumptions regarding the correlations for a variety of covariance structures. The most conservative choice for the correlation depends on the covariance structure and the number of repeated measures. In the absence of good estimates of the correlations, the sample size is often based on a two-sample t-test, making the 'ultra' conservative and unrealistic assumption that there are zero correlations between the baseline and follow-up measures while at the same time assuming there are perfect correlations between the follow-up measures. Compared to the case of taking a single measurement, substantial savings in sample size can be realized by accounting for the repeated measures, even with very conservative assumptions regarding the parameters of the assumed correlation matrix. Assuming compound symmetry, the sample size from the two-sample t-test calculation can be reduced at least 44%, 56%, and 61% for repeated measures analysis of covariance by taking 2, 3, and 4 follow-up measures, respectively. The results offer a rational basis for determining a fairly conservative, yet efficient, sample size for clinical trials with repeated measures and a baseline value.

  11. Investigation of bioactive CaO-P2O5-MgO-SiO2 ceramic composition for orthopedic applications

    NASA Astrophysics Data System (ADS)

    Kaur, Pardeep; Singh, K. J.; Sood, Henna; Arora, Daljit Singh

    2017-05-01

    Bioactive sample of the composition 41CaO-8P2O5-17MgO-34SiO2 has been prepared in the laboratory by quick alkali mediated sol-gel method. 1M ammonia solution has been used to form the gel. Bioactivity of the sample has been analyzed by soaking the samples in simulated body fluid. Degradation study has also undertaken to check the degradation behavior of the sample. MTT cytotoxic test has also been done to know the toxicity of the sample and results show that samples has good percentage of cell viability in the cell culture media. Formation of the hydroxyapatite has been confirmed by the XRD, Raman spectroscopy and FESEM-EDX study.

  12. [Adaptation and psychometric proprieties study for the Portuguese version of the Adolescent Coping Scale - Escala de Coping para Adolescentes].

    PubMed

    Guerreiro, Diogo Frasquilho; Cruz, Diana; Figueira, Maria Luísa; Sampaio, Daniel

    2014-01-01

    Coping is a psychological process that prompts the individual to adapt to stressful situations. The Adolescent Coping Scale is a widely used research and clinical tool. This study aimed to develop a Portuguese version of the Adolescent Coping Scale and to analyze the strategies and coping styles of young people in our sample. An anonymous questionnaire comprising the Adolescent Coping Scale was submitted and replied by 1 713 students (56% female, from 12 to 20 years, average age 16) The validity study of the scale included: principal component and reliability analysis; confirmatory analysis using structural equation modelling Subsequently, a gender comparison of both the strategies and the coping styles was conducted through independent samples t tests. The final structure of the Adolescent Coping Scale adaptation retained 70 items assessing 16 coping strategies grouped into three major styles. The scales showed good internal consistency (Cronbach alpha values between 0.63. and 0.86, with the exception of one dimension that as shown a value of 0.55) and the confirmatory model showed a good fit (goodness of fit index values between 0.94 e 0.96). Two coping strategies were eliminated on statistical grounds (insufficient saturations of items in the corresponding dimensions). We found that the style of coping focused on problem solving is the most used by youths from our sample, in both sexes. Females had higher mean values in non-productive coping style and reference to others. This adapted version has high similarity with the original scale, with expectable minor changes, given that coping is influenced by cultural, geographical and socio-economic variables. The present study represents an important part of the validation protocol Portuguese Adolescent Coping Scale, including its linguistic adaptation and its internal consistency and factor structure studies.

  13. Validation of a Spanish-language version of the ADHD Rating Scale IV in a Spanish sample.

    PubMed

    Vallejo-Valdivielso, M; Soutullo, C A; de Castro-Manglano, P; Marín-Méndez, J J; Díez-Suárez, A

    2017-07-14

    The purpose of this study is to validate a Spanish-language version of the 18-item ADHD Rating Scale-IV (ADHD-RS-IV.es) in a Spanish sample. From a total sample of 652 children and adolescents aged 6 to 17 years (mean age was 11.14±3.27), we included 518 who met the DSM-IV-TR criteria for ADHD and 134 healthy controls. To evaluate the factorial structure, validity, and reliability of the scale, we performed a confirmatory factor analysis (CFA) using structural equation modelling on a polychoric correlation matrix and maximum likelihood estimation. The scale's discriminant validity and predictive value were estimated using ROC (receiver operating characteristics) curve analysis. Both the full scale and the subscales of the Spanish-language version of the ADHD-RS-IV showed good internal consistency. Cronbach's alpha was 0.94 for the full scale and ≥ 0.90 for the subscales, and ordinal alpha was 0.95 and ≥ 0.90, respectively. CFA showed that a two-factor model (inattention and hyperactivity/impulsivity) provided the best fit for the data. ADHD-RS-IV.es offered good discriminant ability to distinguish between patients with ADHD and controls (AUC=0.97). The two-factor structure of the Spanish-language version of the ADHD-RS-IV (ADHD-RS-IV.es) is consistent with those of the DSM-IV-TR and DSM-5 as well as with the model proposed by the author of the original scale. Furthermore, it has good discriminant ability. ADHD-RS-IV.es is therefore a valid and reliable tool for determining presence and severity of ADHD symptoms in the Spanish population. Copyright © 2017 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. A combination of computational-experimental study on metal-organic frameworks MIL-53(Al) as sorbent for simultaneous determination of estrogens and glucocorticoids in water and urine samples by dispersive micro-solid-phase extraction coupled to UPLC-MS/MS.

    PubMed

    Gao, Guihua; Li, Sijia; Li, Shuo; Wang, Yudan; Zhao, Pan; Zhang, Xiangyu; Hou, Xiaohong

    2018-04-01

    In this work, computational and experimental methods were used to study the adsorption of estrogens and glucocorticoids on metal-organic frameworks (MOFs). Computer-aided molecular simulation was applied to predict the adsorption of eight analytes on four MOFs (MIL-101(Cr), MIL-100(Fe), MIL-53(Al), and UiO-66(Zr)) by examining molecular interactions and calculating free binding energies. Subsequently, the four water-stable MOFs were synthesized and evaluated as adsorbents for the target hormones in aqueous solution. As the MOF exhibiting the highest adsorption capacity in both computations and experiments, MIL-53(Al) was chosen as a sorbent to develop a dispersive micro-solid-phase extraction procedure coupled to ultra-performance liquid chromatography tandem mass spectrometry for simultaneous determination of the target analytes in water and human urine samples. Experimental parameters affecting the extraction recoveries, including pH, ionic strength, MIL-53(Al) amount, extraction time, desorption time, and desorption solvent, were optimized. The optimized method provided a linear range of 0.005025-368.6μg/L with good correlation coefficients (0.9982 ≤ r 2 ≤ 0.9992), and limits of detection (S/N = 3) and quantification (S/N = 10) of 0.0015-1.0μg/L and 0.005-1.8μg/L, respectively. The analyte recoveries were in the range of 80.6-98.4% in water samples and 88.4-93.2% in urine samples. Furthermore, MIL-53(Al) showed good stability over 10 extraction cycles (RSD < 10.0%). Good agreement between experimental measurements and computational results showed the potential of this approach for elucidating adsorption mechanisms and predicating extraction efficiencies for MOFs and targets, providing new directions for the development and utilization of MOFs. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. A sandwich-type optical immunosensor based on the alkaline phosphatase enzyme for Salmonella thypimurium detection

    NASA Astrophysics Data System (ADS)

    Widyastuti, E.; Puspitasari Schonherr, M. F.; Masruroh, A.; Anggraeni, R. A.; Nisak, Y. K.; Mursidah, S.

    2018-03-01

    Salmonella is pathogenic bacteria that caused foodborne diseases which being called Salmonellosis. Prevalence of Salmonellosis that being caused by Salmonella thypimurium in Indonesia is quite high. However, detection of Salmonella bacteria in food still limited, complicated, and required a lot time. Sensitive optical assay for Salmonella thypimurium paper based detection has been developed by integrating sandwich assay between antibody-antigen complex and alkaline phosphatase enzyme that produce visible bluish-purple colour with presence of NBT-BCIP substrate. The results showed that Limit of Quantitation of detection is 105 CFU mL-1 with detection time 15 minutes. Linearity test between Colour intensity that produced from Salmonella concentration presence on samples showed that detection has good linearity. Selectivity test exhibited excellent sensitivity with good discrimination against Escherichia coli.

  16. Poly(amidosulfonic acid) modified glassy carbon electrode for determination of isoniazid in pharmaceuticals.

    PubMed

    Yang, Gongjun; Wang, Cunxiao; Zhang, Rui; Wang, Chenying; Qu, Qishu; Hu, Xiaoya

    2008-06-01

    Amidosulfonic acid was electropolymerized by cyclic voltammetry onto the surface of glassy carbon electrode (GCE) to fabricate the chemically modified electrode, which showed high stability, good selectivity and reproducibility for determination of isoniazid. The modified electrode showed an excellent electrocatalytical effect on the oxidation of isoniazid. Under the optimum conditions, there was a good linear relationship between anodic peak current and isoniazid concentration in the range of 5.0 x 10(-8)- 1.0 x 10(-5) M, and a detection limit of 1.0 x 10(-8) M (S/N = 3) was obtained after 120 s at the accumulation potential of - 0.2 V (vs. SCE). This developed method had been applied to the direct determination of isoniazid in injection and tablet samples with satisfactory results.

  17. Treatment of radioactive liquid waste (Co-60) by sorption on Zeolite Na-A prepared from Iraqi kaolin.

    PubMed

    Mustafa, Yasmen A; Zaiter, Maysoon J

    2011-11-30

    Iraqi synthetic zeolite type Na-A has been suggested as ion exchange material to treat cobalt-60 in radioactive liquid waste which came from neutron activation for corrosion products. Batch experiments were conducted to find out the equilibrium isotherm for source sample. The equilibrium isotherm for radioactive cobalt in the source sample showed unfavorable type, while the equilibrium isotherm for the total cobalt (the radioactive and nonradioactive cobalt) in the source sample showed a favorable type. The ability of Na-A zeolite to remove cobalt from wastewater was checked for high cobalt concentration (822 mg/L) in addition to low cobalt concentration in the source sample (0.093 mg/L). A good fitting for the experimental data with Langmuir equilibrium model was observed. Langmuir constant qm which is related to monolayer adsorption capacity for low and high cobalt concentration was determined to be 0.021 and 140 mg/g(zeolite). The effects of important design variables on the zeolite column performance were studied these include initial concentration, flow rate, and bed depth. The experimental results have shown that high sorption capacity can be obtained at high influent concentration, low flow rate, and high bed depth. Higher column performance was obtained at higher bed depth. Thomas model was employed to predict the breakthrough carves for the above variables. A good fitting was observed with correlation coefficients between 0.915 and 0.985. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Effects of common hemoglobin variants on HbA1c measurements in China: results for α- and β-globin variants measured by six methods.

    PubMed

    Xu, Anping; Chen, Weidong; Xia, Yong; Zhou, Yu; Ji, Ling

    2018-04-07

    HbA1c is a widely used biomarker for diabetes mellitus management. Here, we evaluated the accuracy of six methods for determining HbA1c values in Chinese patients with common α- and β-globin chains variants in China. Blood samples from normal subjects and individuals exhibiting hemoglobin variants were analyzed for HbA1c, using Sebia Capillarys 2 Flex Piercing (C2FP), Bio-Rad Variant II Turbo 2.0, Tosoh HLC-723 G8 (ver. 5.24), Arkray ADAMS A1c HA-8180V fast mode, Cobas c501 and Trinity Ultra2 systems. DNA sequencing revealed five common β-globin chain variants and three common α-globin chain variants. The most common variant was Hb E, followed by Hb New York, Hb J-Bangkok, Hb G-Coushatta, Hb Q-Thailand, Hb G-Honolulu, Hb Ube-2 and Hb G-Taipei. Variant II Turbo 2.0, Ultra2 and Cobas c501 showed good agreement with C2FP for most samples with variants. HLC-723 G8 yielded no HbA1c values for Hb J-Bangkok, Hb Q-Thailand and Hb G-Honolulu. Samples with Hb E, Hb G-Coushatta, Hb G-Taipei and Hb Ube-2 produced significant negative biases for HLC-723 G8. HA-8180V showed statistically significant differences for Hb E, Hb G-Coushatta, Hb G-Taipei, Hb Q-Thailand and Hb G-Honolulu. HA-8180V yielded no HbA1c values for Hb J-Bangkok. All methods showed good agreement for samples with Hb New York. Some common hemoglobin variants can interfere with HbA1c determination by the most popular methods in China.

  19. Quality of phenobarbital solid-dosage forms in the urban community of Nouakchott (Mauritania).

    PubMed

    Laroche, Marie-Laure; Traore, Hamidou; Merle, Louis; Gaulier, Jean-Michel; Viana, Marylene; Preux, Pierre-Marie

    2005-08-01

    Epilepsy is a major public-health problem in Africa. The quality of available drugs is a limiting factor for an adequate management. The aim of this study was to describe the proportion of poor-quality phenobarbital (PB) solid-dosage forms and evaluate the factors associated with its quality in Nouakchott (Mauritania). A cross-sectional study was carried out within pharmacies, hospitals, and on the parallel market in March 2003. PB samples were bought by a native person and then assayed by a liquid chromatography method. A package was considered to be of good quality if the active-substance average content was between 85 and 115% of the stated content printed on the packet. Forty-five pharmaceutical stores were visited, enabling us to collect 146 samples of PB. Three brand names were available in Nouakchott. They originated from France, Morocco, Senegal, and Egypt. Results: A prevalence of 13.7%[95% confidence interval (CI), 8.8-20.0] of poor-quality PB was found. All samples from Morocco were underdosed. The generic active content was satisfactory, but saccharose, an excipient with a potential side effects, was identified. Two factors associated with the good quality of PB have been put forward: tablets manufactured in France and loose packaging as generics conditioned in such a way were of good quality. This study shows that the quality of antiepileptic drugs in Africa is still worrying. The setting up of medicine quality control in Mauritania is legitimate. Considering the good quality of generic PB and its lower cost, this type of medicine should be promoted in this region.

  20. End-of-Kindergarten Spelling Outcomes: How Can Spelling Error Analysis Data Inform Beginning Reading Instruction?

    PubMed

    Lee, Julia Ai Cheng; Otaiba, Stephanie Al

    2017-01-01

    In this article, the authors examined the spelling performance of 430 kindergarteners, which included a high risk sample, to determine the relations between end of kindergarten reading and spelling in a high quality language arts setting. The spelling outcomes including the spelling errors between the good and the poor readers were described, analyzed, and compared. The findings suggest that not all the children have acquired the desired standard as outlined by the Common Core State Standards. In addition, not every good reader is a good speller and that not every poor speller is a poor reader. The study shows that spelling tasks that are accompanied by spelling errors analysis provide a powerful window for making instructional sense of children's spelling errors and for individualizing spelling instructional strategies.

  1. Optimisation of a sample preparation procedure for the screening of fungal infection and assessment of deoxynivalenol content in maize using mid-infrared attenuated total reflection spectroscopy.

    PubMed

    Kos, Gregor; Lohninger, Hans; Mizaikoff, Boris; Krska, Rudolf

    2007-07-01

    A sample preparation procedure for the determination of deoxynivalenol (DON) using attenuated total reflection mid-infrared spectroscopy is presented. Repeatable spectra were obtained from samples featuring a narrow particle size distribution. Samples were ground with a centrifugal mill and analysed with an analytical sieve shaker. Particle sizes of <100, 100-250, 250-500, 500-710 and 710-1000 microm were obtained. Repeatability, classification and quantification abilities for DON were compared with non-sieved samples. The 100-250 microm fraction showed the best repeatability. The relative standard deviation of spectral measurements improved from 20 to 4.4% and 100% of sieved samples were correctly classified compared with 79% of non-sieved samples. The DON level in analysed fractions was a good estimate of overall toxin content.

  2. Factor structure and reliability of the depression, anxiety and stress scales in a large Portuguese community sample.

    PubMed

    Vasconcelos-Raposo, José; Fernandes, Helder Miguel; Teixeira, Carla M

    2013-01-01

    The purpose of the present study was to assess the factor structure and reliability of the Depression, Anxiety and Stress Scales (DASS-21) in a large Portuguese community sample. Participants were 1020 adults (585 women and 435 men), with a mean age of 36.74 (SD = 11.90) years. All scales revealed good reliability, with Cronbach's alpha values between .80 (anxiety) and .84 (depression). The internal consistency of the total score was .92. Confirmatory factor analysis revealed that the best-fitting model (*CFI = .940, *RMSEA = .038) consisted of a latent component of general psychological distress (or negative affectivity) plus orthogonal depression, anxiety and stress factors. The Portuguese version of the DASS-21 showed good psychometric properties (factorial validity and reliability) and thus can be used as a reliable and valid instrument for measuring depression, anxiety and stress symptoms.

  3. A new method for stable lead isotope extraction from seawater.

    PubMed

    Zurbrick, Cheryl M; Gallon, Céline; Flegal, A Russell

    2013-10-24

    A new technique for stable lead (Pb) isotope extraction from seawater is established using Toyopearl AF-Chelate 650M(®) resin (Tosoh Bioscience LLC). This new method is advantageous because it is semi-automated and relatively fast; in addition it introduces a relatively low blank by minimizing the volume of chemicals used in the extraction. Subsequent analyses by HR ICP-MS have a good relative external precision (2σ) of 3.5‰ for (206)Pb/(207)Pb, while analyses by MC-ICP-MS have a better relative external precision of 0.6‰. However, Pb sample concentrations limit MC-ICP-MS analyses to (206)Pb, (207)Pb, and (208)Pb. The method was validated by processing the common Pb isotope reference material NIST SRM-981 and several GEOTRACES intercalibration samples, followed by analyses by HR ICP-MS, all of which showed good agreement with previously reported values. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Microbiological quality and safe handling of enteral diets in a hospital in Minas Gerais, Brazil.

    PubMed

    Pinto, Raquel Oliveira Medrado; Correia, Eliznara Fernades; Pereira, Keyla Carvalho; Costa Sobrinho, Paulo de Souza; da Silva, Daniele Ferreira

    2015-06-01

    Contamination of enteral diets represents a high risk of compromising the patient's medical condition. To assess the microbiological quality and aseptic conditions in the preparation and administration of handmade and industrialized enteral diets offered in a hospital in the Valley of Jequitinhonha, MG, Brazil, we performed a microbiological analysis of 50 samples of diets and 27 samples of surfaces, utensils, and water used in the preparation of the diets. In addition, we assessed the good handling practices of enteral diets according to the requirements specified by the Brazilian legislation. Both kinds of enteral diets showed contamination by coliforms and Pseudomonas spp. No sample was positive for Staphylococcus aureus and Salmonella spp. On the other hand, Listeria spp. was detected in only one sample of handmade diets. Contamination was significantly higher in the handmade preparations (p < 0.05). Nonconformities were detected with respect to good handling practices, which may compromise the diet safety. The results indicate that the sanitary quality of the enteral diets is unsatisfactory, especially handmade diets. Contamination by Pseudomonas spp. is significant because it is often involved in infection episodes. With regard to aseptic practices, it was observed the need of implementing new procedures for handling enteral diets.

  5. Antioxidant Capacity, Cytotoxicity and Antimycobacterial Activity of Madeira Archipelago Endemic Helichrysum Dietary and Medicinal Plants.

    PubMed

    Gouveia-Figueira, Sandra C; Gouveia, Carla A; Carvalho, Maria J; Rodrigues, Ana I; Nording, Malin L; Castilho, Paula C

    2014-10-31

    The potential bioactivity of dietary and medicinal endemic Helichrysum plants from Madeira Archipelago was explored, for the first time, in order to supply new information for the general consumer. In vitro antioxidant properties were investigated using DPPH, ABTS(•+), FRAP and β-Carotene assays, and the total phenolic content (TPC) and total flavonoid content (TFC) were also determined. Although the results generally showed a large variation among the three analyzed plants, the methanolic extracts showed the highest antioxidant capacity. Exception is made for H. devium n-hexane extract that showed good radical scavenger capacity associated to compounds with good reducing properties. In the Artemia salina toxicity assay and antimycobaterial activity, H. devium was the most potent plant with the lowest LD50 at 216.7 ± 10.4 and MIC ≤ 50 μg·mL(-1). Chemometric evaluation (Principal Component Analysis-PCA) showed close interdependence between the ABTS, TPC and TFC methods and allowed to group H. devium samples.

  6. Antioxidant Capacity, Cytotoxicity and Antimycobacterial Activity of Madeira Archipelago Endemic Helichrysum Dietary and Medicinal Plants

    PubMed Central

    Gouveia-Figueira, Sandra C.; Gouveia, Carla A.; Carvalho, Maria J.; Rodrigues, Ana I.; Nording, Malin L.; Castilho, Paula C.

    2014-01-01

    The potential bioactivity of dietary and medicinal endemic Helichrysum plants from Madeira Archipelago was explored, for the first time, in order to supply new information for the general consumer. In vitro antioxidant properties were investigated using DPPH, ABTS•+, FRAP and β-Carotene assays, and the total phenolic content (TPC) and total flavonoid content (TFC) were also determined. Although the results generally showed a large variation among the three analyzed plants, the methanolic extracts showed the highest antioxidant capacity. Exception is made for H. devium n-hexane extract that showed good radical scavenger capacity associated to compounds with good reducing properties. In the Artemia salina toxicity assay and antimycobaterial activity, H. devium was the most potent plant with the lowest LD50 at 216.7 ± 10.4 and MIC ≤ 50 μg·mL−1. Chemometric evaluation (Principal Component Analysis—PCA) showed close interdependence between the ABTS, TPC and TFC methods and allowed to group H. devium samples. PMID:26785236

  7. Reliability and Validity of the Devereux Early Childhood Assessment (DECA) as a Function of Parent and Teacher Ratings

    ERIC Educational Resources Information Center

    Barbu, Otilia C.; Levine-Donnerstein, Deborah; Marx, Ronald W.; Yaden, David B., Jr.

    2013-01-01

    This study examined reliability and validity of the Devereux Early Childhood Assessment (DECA), based on samples of parents and teachers' ratings of 1,145 entering kindergartners in the Southwest. Confirmatory factor analysis showed that DECA presented good reliability and validity for manifest variables, corroborating previous findings. Three…

  8. Ferrofluids based on Co-Fe-Si-B amorphous nanoparticles

    NASA Astrophysics Data System (ADS)

    Wang, Tianqi; Bian, Xiufang; Yang, Chuncheng; Zhao, Shuchun; Yu, Mengchun

    2017-03-01

    Magnetic Co-Fe-Si-B amorphous nanoparticles were successfully synthesized by chemical reduction method. ICP, XRD, DSC, and TEM were used to investigate the composition, structure and morphology of Co-Fe-Si-B samples. The results show that the Co-Fe-Si-B samples are amorphous, which consist of nearly spherical nanoparticles with an average particle size about 23 nm. VSM results manifest that the saturation magnetization (Ms) of Co-Fe-Si-B samples ranges from 46.37 to 62.89 emu/g. Two kinds of ferrofluids (FFs) were prepared by dispersing Co-Fe-Si-B amorphous nanoparticles and CoFe2O4 nanoparticles in kerosene and silicone oil, respectively. The magnetic properties, stability and viscosity of the FFs were investigated. The FFs with Co-Fe-Si-B samples have a higher Ms and lower coercivity (Hc) than FFs with CoFe2O4 sample. Under magnetic field, the silicone oil-based FFs exhibit high stability. The viscosity of FFs under different applied magnetic fields was measured by a rotational viscometer, indicating that FFs with Co-Fe-Si-B particles present relative strong response to an external magnetic field. The metal-boride amorphous alloy nanoparticles have potential applications in the preparation of magnetic fluids with good stability and good magnetoviscous properties.

  9. Thermo-responsive polymer tethered metal-organic framework core-shell magnetic microspheres for magnetic solid-phase extraction of alkylphenols from environmental water samples.

    PubMed

    Jia, Yuqian; Su, Hao; Wong, Y-L Elaine; Chen, Xiangfeng; Dominic Chan, T-W

    2016-07-22

    In this work, the thermo-responsive polymer PNIPAM tethered to Fe3O4@SiO2@MOF core-shell magnetic microspheres was first synthesized by a surface-selective post-synthetic strategy and underwent highly efficient magnetic solid-phase extraction (MSPE) of alkylphenols from aqueous samples. Alkylphenols, including 4-tert-octylphenol (OP) and 4-n-nonylphenol (NP), were selected as target compounds. The sample quantification was carried out using LC-MS/MS in multiple reaction monitor (MRM) mode. Under optimal working conditions, the developed method showed good linearity in the range of 5-1000ngL(-1), a low limit of detection (1.5ngL(-1)), and good repeatability (relative standard deviation, <8%, n=5) for NP and OP. Owning to the hydrophilic/hydrophobic switchable properties of the nanocomposite, high recoveries (78.7-104.3%) of alkylphenols were obtained under different extraction conditions. The levels of OP and NP in environmental samples collected from local river, lake and pond waters were analyzed using the developed method. It was believed that the synthesized material with the thermo-responsive coating, large surface areas and magnetic properties should have great potential in the extraction and removal of alkylphenols from environmental samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. [UPLC-MS/MS determination of content of three iridoids of xingnaojing oral preparation in rat brains and study on their brain pharmacokinetics].

    PubMed

    Xu, Pan; Du, Shou-Ying; Lu, Yang; Bai, Jie; Liu, Hui-Min; Du, Qiu; Chen, Zhen-Zhen; Wang, Zhen

    2014-06-01

    To establish a UPLC-MS/MS method for the simultaneous determination of geniposide, genipin 1-O-beta-D-gentiobioside and geniposidic acid in rat brains and study the brain pharmacokinetics of the three iridoid glycosides in stroke rat after the oral administration of Xingnaojing. In this experiment, brain samples were precipitated with protein for twice. Acquity BEH C18 column was adopted, with acetonitrile-0.1% formic acid-water as the mobile phase for gradient elution. ESI source was adopted for mass spectra; multiple reaction monitoring (MRM) was conducted to detect negative ions. The time for sample analysis was 3.5 min. the results showed good linear relations among the three iridoid glycosides, with the extraction recovery between 99.6% and 114.3%, good intra- and inter-day precisions and accuracies and stability in line with the requirements. The t1/2 and MRT in the three components were similar in brains of stroke rats. Geniposide and genipin 1-O-beta-D-gentiobioside showed double peaks; where as geniposidic acid showed a single peak. In conclusion, the method is so specific, sensitive, accurate and reliable that it can be used to study the brain pharmacokinetics of Xingnaojing oral preparation.

  11. Detection of Organophosphorus Pesticides with Colorimetry and Computer Image Analysis.

    PubMed

    Li, Yanjie; Hou, Changjun; Lei, Jincan; Deng, Bo; Huang, Jing; Yang, Mei

    2016-01-01

    Organophosphorus pesticides (OPs) represent a very important class of pesticides that are widely used in agriculture because of their relatively high-performance and moderate environmental persistence, hence the sensitive and specific detection of OPs is highly significant. Based on the inhibitory effect of acetylcholinesterase (AChE) induced by inhibitors, including OPs and carbamates, a colorimetric analysis was used for detection of OPs with computer image analysis of color density in CMYK (cyan, magenta, yellow and black) color space and non-linear modeling. The results showed that there was a gradually weakened trend of yellow intensity with the increase of the concentration of dichlorvos. The quantitative analysis of dichlorvos was achieved by Artificial Neural Network (ANN) modeling, and the results showed that the established model had a good predictive ability between training sets and predictive sets. Real cabbage samples containing dichlorvos were detected by colorimetry and gas chromatography (GC), respectively. The results showed that there was no significant difference between colorimetry and GC (P > 0.05). The experiments of accuracy, precision and repeatability revealed good performance for detection of OPs. AChE can also be inhibited by carbamates, and therefore this method has potential applications in real samples for OPs and carbamates because of high selectivity and sensitivity.

  12. Determination of total sulfur in lichens and plants by combustion-infrared analysis

    USGS Publications Warehouse

    Jackson, L.L.; Engleman, E.E.; Peard, J.L.

    1985-01-01

    Sulfur was determined in plants and lichens by combustion of the sample and infrared detection of evolved sulfur dioxide using an automated sulfur analyzer. Vanadium pentaoxide was used as a combustion accelerator. Pelletization of the sample prior to combustion was not found to be advantageous. Washing studies showed that leaching of sulfur was not a major factor in the sample preparation. The combustion-IR analysis usually gave higher sulfur content than the turbidimetric analysis as well as shorter analysis time. Relative standard deviations of less than 7% were obtained by the combustion-IR technique when sulfur levels in plant material ranged from 0.05 to 0.70%. Determination of sulfur in National Bureau of Standards botanical reference materials showed good agreement between the combustion-IR technique and other instrumental procedures. Seven NBS botanical reference materials were analyzed.

  13. Magnetic sporopollenin-cyanopropyltriethoxysilane-dispersive micro-solid phase extraction coupled with high performance liquid chromatography for the determination of selected non-steroidal anti-inflammatory drugs in water samples.

    PubMed

    Abd Wahib, Siti Munirah; Wan Ibrahim, Wan Aini; Sanagi, Mohd Marsin; Kamboh, Muhammad Afzal; Abdul Keyon, Aemi S

    2018-01-12

    A facile dispersive-micro-solid phase extraction (D-μ-SPE) method coupled with HPLC for the analysis of selected non-steroidal anti-inflammatory drugs (NSAIDs) in water samples was developed using a newly prepared magnetic sporopollenin-cyanopropyltriethoxysilane (MS-CNPrTEOS) sorbent. Sporopollenin homogenous microparticles of Lycopodium clavatum spores possessed accessible functional groups that facilitated surface modification. Simple modification was performed by functionalization with 3-cyanopropyltriethoxysilane (CNPrTEOS) and magnetite was introduced onto the biopolymer to simplify the extraction process. MS-CNPrTEOS was identified by infrared spectrometrywhile the morphology and the magnetic property were confirmed by scanning electron microscopy (SEM) and vibrating sample magnetometer (VSM), respectively. To maximize the extraction performance of ketoprofen, ibuprofen, diclofenac and mefenamic acid using the proposed MS-CNPrTEOS, important D-μ-SPE parameters were comprehensively optimized. The optimum extraction conditions were sorbent amount, 40 mg; extraction time, 5 min; desorption time; 5 min; sample volume, 15 mL; sample pH 2.0; and salt addition, 2.5% (w/v). The feasibility of the developed method was evaluated using spiked tap water, lake water, river water and waste water samples. Results showed that ketoprofen and ibuprofen were linear in the range of 1.0-1000 μg L -1 whilst diclofenac and mefenamic acid were linear in the range 0.8-500 μg L -1 . The results also showed good detection limits for the studied NSAIDs in the range of 0.21-0.51 μg L -1 and good recoveries for spiked water samples in the range of 85.1-106.4%. The MS-CNPrTEOS proved a promising dispersive sorbent and applicable to facile and rapid assay of NSAIDs in water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Self-perceived health in older Europeans: Does the choice of survey matter?

    PubMed Central

    Croezen, Simone; Burdorf, Alex

    2016-01-01

    Abstract Background: Cross-national comparisons of health in European countries provide crucial information to monitor health and disease within and between countries and to inform policy and research priorities. However, variations in estimates might occur when information from cross-national European surveys with different characteristics are used. We compared the prevalence of very good or good self-perceived health across 10 European countries according to three European surveys and investigated which survey characteristics contributed to differences in prevalence estimates. Methods: We used aggregate data from 2004 to 2005 of respondents aged 55–64 years from the European Union Statistics on Income and Living Conditions (EU-SILC), the Survey of Health, Ageing and Retirement in Europe (SHARE) and the European Social Survey (ESS). Across the surveys, self-perceived health was assessed by the same question with response options ranging from very good to very bad. Results: Despite a good correlation between the surveys (intraclass correlation coefficient: 0.77), significant differences were found in prevalence estimates of very good or good self-perceived health. The survey response, sample size and survey mode contributed statistically significantly to the differences between the surveys. Multilevel linear regression analyses, adjusted for survey characteristics, showed a higher prevalence for SHARE (+6.96, 95% CIs: 3.14 to 10.8) and a lower prevalence (−3.12; 95% CIs: −7.11 to 0.86) for ESS, with EU-SILC as the reference survey. Conclusion: Three important health surveys in Europe showed substantial differences for presence of very good or good self-perceived health. These differences limit the usefulness for direct comparisons across studies in health policies for Europe. PMID:26989125

  15. Insufficient quality of sputum submitted for tuberculosis diagnosis and associated factors, in Klaten district, Indonesia

    PubMed Central

    Sakundarno, Mateus; Nurjazuli, Nurjazuli; Jati, Sutopo Patria; Sariningdyah, Retna; Purwadi, Sumarsono; Alisjahbana, Bachti; van der Werf, Marieke J

    2009-01-01

    Background Sputum smear microscopy is the standard diagnostic method for detection of smear positive pulmonary tuberculosis (TB). Insufficient quality of sputum might result in missing cases. In this study we aimed at assessing the quality of sputum in a district in Central Java and determining patient and health worker factors associated with submission of three good quality sputum samples. Methods In 16 health centers information was collected on the quality of sputum submitted by TB suspects, i.e. volume, color, and viscosity. TB suspects were interviewed to assess their knowledge of TB, motivation to provide sputum and whether they were informed why and how to produce a sputum sample. Health workers were interviewed to assess what information they provided to TB suspects about the reason for sputum examination, methods to produce sputum and characteristics of a good quality sputum sample. All health worker and patient factors were evaluated for association with sputum quality. Results Of 387 TB suspects, 294 (76.0%) could be traced and interviewed, and of 272 (70.3%) information about sputum quality was available. Of those 203 (74.6%) submitted three samples, 90 (33.1%) provided at least one good sample, and 37 (13.6%) provided three good quality sputum samples. Of the 272 TB suspects, 168 (61.8%) mentioned that information on the reason for sputum examination was provided, 66 (24.3%) remembered that they were informed about how to produce sputum and 40 (14.7%) recalled being informed about the characteristics of good quality sputum. Paramedics reported to provide often/always information on the importance of sputum examination, and when to produce sputum. Information on how to produce sputum and characteristics of a good sputum sample was less often provided. None of the studied patient characteristics or health worker factors was associated with providing good quality sputum. Conclusion A considerable number of TB suspects did not provide three sputum samples and a large number of sputum samples were of insufficient quality. Training of health workers in providing health education to the TB suspect about the reason for sputum examination and how to produce a good quality sputum sample should be a priority of the TB program. PMID:19426477

  16. Effects of Nanowire Length and Surface Roughness on the Electrochemical Sensor Properties of Nafion-Free, Vertically Aligned Pt Nanowire Array Electrodes

    PubMed Central

    Li, Zhiyang; Leung, Calvin; Gao, Fan; Gu, Zhiyong

    2015-01-01

    In this paper, vertically aligned Pt nanowire arrays (PtNWA) with different lengths and surface roughnesses were fabricated and their electrochemical performance toward hydrogen peroxide (H2O2) detection was studied. The nanowire arrays were synthesized by electroplating Pt in nanopores of anodic aluminum oxide (AAO) template. Different parameters, such as current density and deposition time, were precisely controlled to synthesize nanowires with different surface roughnesses and various lengths from 3 μm to 12 μm. The PtNWA electrodes showed better performance than the conventional electrodes modified by Pt nanowires randomly dispersed on the electrode surface. The results indicate that both the length and surface roughness can affect the sensing performance of vertically aligned Pt nanowire array electrodes. Generally, longer nanowires with rougher surfaces showed better electrochemical sensing performance. The 12 μm rough surface PtNWA presented the largest sensitivity (654 μA·mM−1·cm−2) among all the nanowires studied, and showed a limit of detection of 2.4 μM. The 12 μm rough surface PtNWA electrode also showed good anti-interference property from chemicals that are typically present in the biological samples such as ascorbic, uric acid, citric acid, and glucose. The sensing performance in real samples (river water) was tested and good recovery was observed. These Nafion-free, vertically aligned Pt nanowires with surface roughness control show great promise as versatile electrochemical sensors and biosensors. PMID:26404303

  17. C18-coated stir bar sorptive extraction combined with high performance liquid chromatography-electrospray tandem mass spectrometry for the analysis of sulfonamides in milk and milk powder.

    PubMed

    Yu, Chunhe; Hu, Bin

    2012-02-15

    A simple, rapid, sensitive, inexpensive and less sample consuming method of C(18)-stir bar sorptive extraction (SBSE)-high performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) was proposed for the determination of six sulfonamides in milk and milk powder samples. C(18) silica particles coated stir bar was prepared by adhesion method, and two kinds of adhesive glue, polydimethylsiloxane (PDMS) sol and epoxy glue were tried. It was found that the C(18)-coated stir bar prepared by PDMS sol as adhesive glue is more robust than that prepared by epoxy glue when liquid desorption was employed, in terms of both lifetime and organic solvent tolerance. The preparation of C(18) stir bar was simple with good mechanic strength and the stir bar could be reused for more than 20 times. Granular coating has relatively high specific surface area and is propitious to sorptive extraction based process. Compared to conventional PDMS SBSE coating, C(18) coating shows good affinity to the target polar/weak polar sulfonamides. To achieve optimum SBSE extraction performance, several parameters including extraction and desorption time, ionic strength, sample pH and stirring speed were investigated. The detection limits of the proposed method for six sulfonamides were in the range of 0.9-10.5 μg/L for milk and 2.7-31.5 μg/kg for milk powder. Good linearities were obtained for sulfonamides with the correlation coefficients (R) above 0.9922. Finally, the proposed method was successfully applied to the determination of sulfonamides in milk and milk powder samples and satisfied recoveries of spiked target compounds in real samples were obtained. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Preliminary investigation of mineral content of pollen collected from different Serbian maize hybrids - is there any potential nutritional value?

    PubMed

    Kostić, Aleksandar Ž; Kaluđerović, Lazar M; Dojčinović, Biljana P; Barać, Miroljub B; Babić, Vojka B; Mačukanović-Jocić, Marina P

    2017-07-01

    Bee pollen has already proved to be a good supplement rich in iron and zinc. Studies on the application of flower pollen in the food industry and medicine have begun. Bearing in mind the prevalence of maize as a crop culture, its pollen will be easily available. The mineral composition of pollen of seven Serbian maize hybrids was analyzed in order to establish its nutritional value and the benefits of its implementation in the human diet using the inductively coupled plasma method. The presence of twenty four different macro- (nine) and micronutrients (fifteen) was detected. The most common minerals were phosphorus and potassium, while arsenic, cobalt, lead, nickel and molybdenum were found in some samples. Comparing the results obtained with recommended or tolerable dietary intake references for adults, it was found that maize pollen can be used as a very good source of zinc, iron, chromium and manganese for humans. With regard to selenium content, pollen samples proved to be moderately good source of this important micronutrient. Contents of some elements (Fe, Zn, Mn, Cr, Se, Al and V) showed significant differences depending on hybrid type. In some samples increased concentrations of aluminum and vanadium were recorded, which may pose a potential problem due to their toxicity. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  19. Minnesota Impulse Disorders Interview (MIDI): Validation of a structured diagnostic clinical interview for impulse control disorders in an enriched community sample.

    PubMed

    Chamberlain, Samuel R; Grant, Jon E

    2018-07-01

    Disorders of impulsivity are common, functionally impairing, and highly relevant across different clinical and research settings. Few structured clinical interviews for the identification and diagnosis of impulse control disorders exist, and none have been validated in a community sample in terms of psychometric properties. The Minnesota Impulse control disorders Interview (MIDI v2.0) was administered to an enriched sample of 293 non-treatment seeking adults aged 18-35 years, recruited using media advertisements in two large US cities. In addition to the MIDI, participants undertook extended clinical interview for other mental disorders, the Barratt impulsiveness questionnaire, and the Padua obsessive-compulsive inventory. The psychometric properties of the MIDI were characterized. In logistic regression, the MIDI showed good concurrent validity against the reference measures (versus gambling disorder interview, p < 0.001; Barratt impulsiveness attentional and non-planning scores p < 0.05), and good discriminant validity versus primarily non-impulsive symptoms, including against anxiety, depression, and obsessive-compulsive symptoms (all p > 0.05). Test re-test reliability was excellent (0.95). The MIDI has good psychometric properties and thus may be a valuable interview tool for clinical and research studies involving impulse control disorders. Further research is needed to better understanding the optimal diagnostic classification and neurobiology of these neglected disorders. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  20. Morphologies, microstructures, and mechanical properties of samples produced using laser metal deposition with 316 L stainless steel wire

    NASA Astrophysics Data System (ADS)

    Xu, Xiang; Mi, Gaoyang; Luo, Yuanqing; Jiang, Ping; Shao, Xinyu; Wang, Chunming

    2017-07-01

    Laser metal deposition (LMD) with a filler has been demonstrated to be an effective method for additive manufacturing because of its high material deposition efficiency, improved surface quality, reduced material wastage, and cleaner process environment without metal dust pollution. In this study, single beads and samples with ten layers were successfully deposited on a 316 L stainless steel surface under optimized conditions using a 4000 W continuous wave fibre laser and an arc welding machine. The results showed that satisfactory layered samples with a large deposition height and smooth side surface could be achieved under appropriate parameters. The uniform structures had fine cellular and network austenite grains with good metallurgical bonding between layers, showing an austenite solidification mode. Precipitated ferrite at the grain boundaries showed a subgrain structure with fine uniform grain size. A higher microhardness (205-226 HV) was detected in the middle of the deposition area, while the tensile strength of the 50 layer sample reached 669 MPa. In addition, ductile fracturing was proven by the emergence of obvious dimples at the fracture surface.

  1. Effect of film thickness on soft magnetic behavior of Fe2CoSi Heusler alloy for spin transfer torque device applications

    NASA Astrophysics Data System (ADS)

    Asvini, V.; Saravanan, G.; Kalaiezhily, R. K.; Raja, M. Manivel; Ravichandran, K.

    2018-04-01

    Fe2CoSi based Heusler alloy thin films were deposited on Si (111) wafer (substrate) of varying thickness using ultra high vacuum DC magnetron sputtering. The structural behavior was observed and found to be hold the L21 structure. The deposited thin films were characterized magnetic properties using vibrating sample magnetometer; the result shows a very high saturated magnetization (Ms), lowest coercivity (Hc), high curie transition temperature (Tc) and low hysteresis loss. Thin film thickness of 75 nm Fe2CoSi sample maintained at substrate temperature 450°C shows the lowest coercivity (Hc=7 Oe). In general, Fe2CoSi Heusler alloys curie transition temperature is very high, due to strong exchange interaction between the Fe and Co atoms. The substrate temperature was kept constant at 450°C for varying thickness (e.g. 5, 20, 50, 75 and 100 nm) of thin film sample. The 75 nm thickness thin film sample shows well crystallanity and good magnetic properties, further squareness ratio in B-H loop increases with the increase in film thickness.

  2. Development of an LC-MS/MS method for the determination of endogenous cortisol in hair using (13)C3-labeled cortisol as surrogate analyte.

    PubMed

    Binz, Tina M; Braun, Ueli; Baumgartner, Markus R; Kraemer, Thomas

    2016-10-15

    Hair cortisol levels are increasingly applied as a measure for stress in humans and mammals. Cortisol is an endogenous compound and is always present within the hair matrix. Therefore, "cortisol-free hair matrix" is a critical point for any analytical method to accurately quantify especially low cortisol levels. The aim of this project was to modify current methods used for hair cortisol analysis to more accurately determine low endogenous cortisol concentrations in hair. For that purpose, (13)C3-labeled cortisol, which is not naturally present in hair (above 13C natural abundance levels), was used for calibration and comparative validation applying cortisol versus (13)C3-labeled cortisol. Cortisol was extracted from 20mg hair (standard sample amount) applying an optimized single step extraction protocol. An LC-MS/MS method was developed for the quantitative analysis of cortisol using either cortisol or (13)C3-cortisol as calibrators and D7-cortisone as internal standard (IS). The two methods (cortisol/(13)C3-labeled cortisol) were validated in a concentration range up to 500pg/mg and showed good linearity for both analytes (cortisol: R(2)=0.9995; (13)C3-cortisol R(2)=0.9992). Slight differences were observed for limit of detection (LOD) (0.2pg/mg/0.1pg/mg) and limit of quantification (LOQ) (1pg/mg/0.5pg/mg). Precision was good with a maximum deviation of 8.8% and 10% for cortisol and (13)C3-cortisol respectively. Accuracy and matrix effects were good for both analytes except for the quality control (QC) low cortisol. QC low (2.5pg/mg) showed matrix effects (126.5%, RSD 35.5%) and accuracy showed a deviation of 26% when using cortisol to spike. These effects are likely to be caused by the unknown amount of endogenous cortisol in the different hair samples used to determine validation parameters like matrix effect, LOQ and accuracy. No matrix effects were observed for the high QC (400pg/mg) samples. Recovery was good with 92.7%/87.3% (RSD 9.9%/6.2%) for QC low and 102.3%/82.1% (RSD 5.8%/11.4%) for QC high. After successful validation the applicability of the method could be proven. The study shows that the method is especially useful for determining low endogenous cortisol concentrations as they occur in cow hair for example. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Separation and quantitation of debrisoquine and 4-hydroxydebrisoquine in human urine by capillary electrophoresis and high-performance liquid chromatography.

    PubMed

    Cifuentes, A; Valencia, J; Sanz, E; Sánchez, M J; Rodríguez-Delgado, M A

    1997-08-22

    A comparative study on the use of reversed-phase high-performance liquid chromatography (RP-HPLC) and capillary electrophoresis (CE) for the determination of debrisoquine (D) and its metabolite, 4-hydroxydebrisoquine (4-HD), in human urine is presented. Four different urine pre-treatments are compared for purification of samples prior to their injection in HPLC and CE. The use of a solid-phase extraction with a C18 cartridge provides the best results for the urine sample treatment, with good recoveries, i.e., 94.5% for D and 93.4% for 4-HD, and high reproducibility, i.e., R.S.D. N = 10 values of 1.7% and 1.2%, respectively. Under our separation conditions it is shown that CE is twice as fast and provides slightly better analysis time reproducibility than HPLC for this type of sample. Both the sensitivity and peak area reproducibility are better when HPLC is used. The two techniques show good agreement when employed for determination of phenotypes for hydroxylation, which seems to corroborate the usefulness of CE for this type of study.

  4. Psychometric Properties of the Theory of Mind Assessment Scale in a Sample of Adolescents and Adults.

    PubMed

    Bosco, Francesca M; Gabbatore, Ilaria; Tirassa, Maurizio; Testa, Silvia

    2016-01-01

    This research aimed at the evaluation of the psychometric properties of the Theory of Mind Assessment Scale (Th.o.m.a.s.). Th.o.m.a.s. is a semi-structured interview meant to evaluate a person's Theory of Mind (ToM). It is composed of several questions organized in four scales, each focusing on one of the areas of knowledge in which such faculty may manifest itself: Scale A (I-Me) investigates first-order first-person ToM; Scale B (Other-Self) investigates third-person ToM from an allocentric perspective; Scale C (I-Other) again investigates third-person ToM, but from an egocentric perspective; and Scale D (Other-Me) investigates second-order ToM. The psychometric proprieties of Th.o.m.a.s. were evaluated in a sample of 156 healthy persons: 80 preadolescent and adolescent (aged 11-17 years, 42 females) and 76 adults (aged from 20 to 67 years, 35 females). Th.o.m.a.s. scores show good inter-rater agreement and internal consistency; the scores increase with age. Evidence of criterion validity was found as Scale B scores were correlated with those of an independent instrument for the evaluation of ToM, the Strange Stories task. Confirmatory factor analysis (CFA) showed good fit of the four-factors theoretical model to the data, although the four factors were highly correlated. For each of the four scales, Rasch analyses showed that, with few exceptions, items fitted the Partial credit model and their functioning was invariant for gender and age. The results of this study, along with those of previous researches with clinical samples, show that Th.o.m.a.s. is a promising instrument to assess ToM in different populations.

  5. Comparison of Abbott RealTime genotype II, GeneMatrix restriction fragment mass polymorphism and Sysmex HISCL HCV Gr assays for hepatitis C virus genotyping.

    PubMed

    Han, Mi-Soon; Park, Yongjung; Kim, Hyon-Suk

    2017-07-26

    Hepatitis C virus (HCV) genotype is a predictive marker for treatment response. We sequentially evaluated the performances of two nucleic acid amplification tests (NAATs) and one serology assay for HCV genotype: Abbott RealTime genotype II (RealTime II), GeneMatrix restriction fragment mass polymorphism (RFMP), and Sysmex HISCL HCV Gr (HISCL Gr). We examined 281 clinical samples with three assays. The accuracy was assessed using the HCV Genotype Performance Panel PHW204 (SeraCare Life Sciences) for two NAATs. Discrepant cases were re-genotyped by the Versant HCV v.2.0 (line probe 2.0) assay. With the RealTime II assay, clinic samples were analyzed as follows: genotypes 1b (43.1%), 2 (40.2%), 1 subtypes other than 1a and 1b (12.5%), 3 (1.8%), 4 (1.4%), 1a (0.7%), 6 (0.4%), and mixed (1.1%). The RealTime II and RFMP assays showed a type concordance rate of 97.5% (274/281) (κ=0.80) and no significant discordance (p=0.25). Both assays accurately genotyped all samples in the Performance Panel by the subtype level. The HISCL Gr assay showed concordance rates of about 91% (κ<0.40) and statistically significant discordances with two NAATs (p<0.05). In confirmation tests, the results of RFMP assay were the most consistent with those of Versant 2.0 assay. The three HCV assays provided genotyping and serotyping results with good concordance rates. The two NAATs (RealTime II and RFMP) showed comparable performance and good agreement. However, the results of the HISCL Gr assay showed statistically significant differences with those of the NAATs.

  6. Psychometric Properties of the Theory of Mind Assessment Scale in a Sample of Adolescents and Adults

    PubMed Central

    Bosco, Francesca M.; Gabbatore, Ilaria; Tirassa, Maurizio; Testa, Silvia

    2016-01-01

    This research aimed at the evaluation of the psychometric properties of the Theory of Mind Assessment Scale (Th.o.m.a.s.). Th.o.m.a.s. is a semi-structured interview meant to evaluate a person's Theory of Mind (ToM). It is composed of several questions organized in four scales, each focusing on one of the areas of knowledge in which such faculty may manifest itself: Scale A (I-Me) investigates first-order first-person ToM; Scale B (Other-Self) investigates third-person ToM from an allocentric perspective; Scale C (I-Other) again investigates third-person ToM, but from an egocentric perspective; and Scale D (Other-Me) investigates second-order ToM. The psychometric proprieties of Th.o.m.a.s. were evaluated in a sample of 156 healthy persons: 80 preadolescent and adolescent (aged 11–17 years, 42 females) and 76 adults (aged from 20 to 67 years, 35 females). Th.o.m.a.s. scores show good inter-rater agreement and internal consistency; the scores increase with age. Evidence of criterion validity was found as Scale B scores were correlated with those of an independent instrument for the evaluation of ToM, the Strange Stories task. Confirmatory factor analysis (CFA) showed good fit of the four-factors theoretical model to the data, although the four factors were highly correlated. For each of the four scales, Rasch analyses showed that, with few exceptions, items fitted the Partial credit model and their functioning was invariant for gender and age. The results of this study, along with those of previous researches with clinical samples, show that Th.o.m.a.s. is a promising instrument to assess ToM in different populations. PMID:27242563

  7. Assessment of groundwater quality and evaluation of scaling and corrosiveness potential of drinking water samples in villages of Chabahr city, Sistan and Baluchistan province in Iran.

    PubMed

    Abbasnia, Abbas; Alimohammadi, Mahmood; Mahvi, Amir Hossein; Nabizadeh, Ramin; Yousefi, Mahmood; Mohammadi, Ali Akbar; Pasalari, Hassan; Mirzabeigi, Majid

    2018-02-01

    The aims of this study were to assess and analysis of drinking water quality of Chabahar villages in Sistan and Baluchistan province by water quality index (WQI) and to investigate the water stability in subjected area. The results illustrated that the average values of LSI, RSI, PSI, LS, and AI was 0.5 (±0.34), 6.76 (±0.6), 6.50 (±0.99), 2.71 (±1.59), and 12.63 (±0.34), respectively. The calculation of WQI for groundwater samples indicated that 25% of the samples could be considered as excellent water, 50% of the samples were classified as good water category and 25% of the samples showed poor water category.

  8. A sensitive, selective and rapid determination of lead(II) ions in real-life samples using an electrochemically reduced graphene oxide-graphite reinforced carbon electrode.

    PubMed

    Hamsawahini, Kunashegaran; Sathishkumar, Palanivel; Ahamad, Rahmalan; Yusoff, Abdull Rahim Mohd

    2015-11-01

    In this study, a sensitive and cost-effective electrochemically reduced graphene oxide (ErGO) on graphite reinforced carbon (GRC) was developed for the detection of lead (Pb(II)) ions present in the real-life samples. A film of graphene oxide (GO) was drop-casted on GRC and their electrochemical properties were investigated using cyclic voltammetry (CV), amperometry and square wave voltammetry (SWV). Factors influencing the detection of Pb(II) ions, such as grades of GRC, constant applied cathodic potential (CACP), concentration of hydrochloric acid and drop-casting drying time were optimised. GO is irreversibly reduced in the range of -0.7 V to -1.6 V vs Ag/AgCl (3 M) in acidic condition. The results showed that the reduction behaviour of GO contributed to the high sensitivity of Pb(II) ions detection even at nanomolar level. The ErGO-GRC showed the detection limit of 0.5 nM and linear range of 3-15 nM in HCl (1 M). The developed electrode has potential to be a good candidate for the determination of Pb(II) ions in different aqueous system. The proposed method gives a good recovery rate of Pb(II) ions in real-life water samples such as tap water and river water. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Psychometrics of the screen for adult anxiety related disorders (SCAARED)- A new scale for the assessment of DSM-5 anxiety disorders.

    PubMed

    Angulo, Melina; Rooks, Brian T; Gill, MaryKay; Goldstein, Tina; Sakolsky, Dara; Goldstein, Benjamin; Monk, Kelly; Hickey, Mary Beth; Diler, Rasim S; Hafeman, Danella; Merranko, John; Axelson, David; Birmaher, Boris

    2017-07-01

    To examine the psychometrics of the Screen for Adult Anxiety Related Disorders (SCAARED). The SCAARED was adapted from the Screen for Child Anxiety Related Emotional Disorders. Participants (N=336) ages 18-27 years old were evaluated using the Structured Clinical Interview for DSM-IV Disorders (SCID). The SCAARED was completed at or within two-weeks before the SCID. The psychometrics of the SCAARED were analyzed using standard statistical analyses including principal components, and Receiver Operant Curve analyses. A replication was performed in an age/sex matched independent sample (N=158). The SCAARED showed four factors: somatic/panic/agoraphobia, generalized anxiety, separation anxiety, and social anxiety. The total and each factor scores demonstrated good internal consistency (α=0.86-0.97) and good discriminant validity between anxiety and other disorders and within anxiety disorders for generalized and social anxiety. Area Under the Curve for the total and each of the factor scores ranged between 0.72 and 0.84 (p<0.0001). These results were replicated in the independent sample. The SCAARED showed excellent psychometric properties supporting its use to screen adults for anxiety disorders, longitudinal studies following youth into adulthood and studies comparing child and adult populations. Further replication studies in larger community and clinical samples are indicated. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  10. Direct synthesis of nitrogen-doped graphene on platinum wire as a new fiber coating method for the solid-phase microextraction of BXes in water samples: Comparison of headspace and cold-fiber headspace modes.

    PubMed

    Memarian, Elham; Hosseiny Davarani, Saied Saeed; Nojavan, Saeed; Movahed, Siyavash Kazemi

    2016-09-07

    In this work, a new solid-phase microextraction fiber was prepared based on nitrogen-doped graphene (N-doped G). Moreover, a new strategy was proposed to solve problems dealt in direct coating of N-doped G. For this purpose, first, Graphene oxide (GO) was coated on Pt wire by electrophoretic deposition method. Then, chemical reduction of coated GO to N-doped G was accomplished by hydrazine and NH3. The prepared fiber showed good mechanical and thermal stabilities. The obtained fiber was used in two different modes (conventional headspace solid-phase microextraction and cold-fiber headspace solid-phase microextraction (CF-HS-SPME)). Both modes were optimized and applied for the extraction of benzene and xylenes from different aqueous samples. All effective parameters including extraction time, salt content, stirring rate, and desorption time were optimized. The optimized CF-HS-SPME combined with GC-FID showed good limit of detections (LODs) (0.3-2.3 μg/L), limit of quantifications (LOQs) (1.0-7.0 μg/L) and linear ranges (1.0-5000 μg/L). The developed method was applied for the analysis of benzene and xylenes in rainwater and some wastewater samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Simultaneous Determination of Metamizole, Thiamin and Pyridoxin Using UV-Spectroscopy in Combination with Multivariate Calibration

    PubMed Central

    Chotimah, Chusnul; Sudjadi; Riyanto, Sugeng; Rohman, Abdul

    2015-01-01

    Purpose: Analysis of drugs in multicomponent system officially is carried out using chromatographic technique, however, this technique is too laborious and involving sophisticated instrument. Therefore, UV-VIS spectrophotometry coupled with multivariate calibration of partial least square (PLS) for quantitative analysis of metamizole, thiamin and pyridoxin is developed in the presence of cyanocobalamine without any separation step. Methods: The calibration and validation samples are prepared. The calibration model is prepared by developing a series of sample mixture consisting these drugs in certain proportion. Cross validation of calibration sample using leave one out technique is used to identify the smaller set of components that provide the greatest predictive ability. The evaluation of calibration model was based on the coefficient of determination (R2) and root mean square error of calibration (RMSEC). Results: The results showed that the coefficient of determination (R2) for the relationship between actual values and predicted values for all studied drugs was higher than 0.99 indicating good accuracy. The RMSEC values obtained were relatively low, indicating good precision. The accuracy and presision results of developed method showed no significant difference compared to those obtained by official method of HPLC. Conclusion: The developed method (UV-VIS spectrophotometry in combination with PLS) was succesfully used for analysis of metamizole, thiamin and pyridoxin in tablet dosage form. PMID:26819934

  12. Cork-based activated carbons as supported adsorbent materials for trace level analysis of ibuprofen and clofibric acid in environmental and biological matrices.

    PubMed

    Neng, N R; Mestre, A S; Carvalho, A P; Nogueira, J M F

    2011-09-16

    In this contribution, powdered activated carbons (ACs) from cork waste were supported for bar adsorptive micro-extraction (BAμE), as novel adsorbent phases for the analysis of polar compounds. By combining this approach with liquid desorption followed by high performance liquid chromatography with diode array detection (BAμE(AC)-LD/HPLC-DAD), good analytical performance was achieved using clofibric acid (CLOF) and ibuprofen (IBU) model compounds in environmental and biological matrices. Assays performed on 30 mL water samples spiked at the 25.0 μg L(-1) level yielded recoveries around 80% for CLOF and 95% for IBU, under optimized experimental conditions. The ACs textural and surface chemistry properties were correlated with the results obtained. The analytical performance showed good precision (<15%), suitable detection limits (0.24 and 0.78 μg L(-1) for CLOF and IBU, respectively) and good linear dynamic ranges (r(2)>0.9922) from 1.0 to 600.0 μg L(-1). By using the standard addition methodology, the application of the present approach to environmental water and urine matrices allowed remarkable performance at the trace level. The proposed methodology proved to be a viable alternative for acidic pharmaceuticals analysis, showing to be easy to implement, reliable, sensitive and requiring low sample volume to monitor these priority compounds in environmental and biological matrices. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. A sample-to-result system for blood coagulation tests on a microfluidic disk analyzer

    PubMed Central

    Lin, Chia-Hui; Liu, Cheng-Yuan; Shih, Chih-Hsin; Lu, Chien-Hsing

    2014-01-01

    In this report, we describe in detail a microfluidic analyzer, which is able to conduct blood coagulation tests using whole blood samples. Sample preparation steps, such as whole blood aliquoting and metering, plasma separation, decanting, and mixing with reagents were performed in sequence through microfluidic functions integrated on a disk. Both prothrombin time (PT) and activated partial thromboplastin time (aPTT) were carried out on the same platform and the test results can be reported in 5 min. Fifty clinical samples were tested for both PT and aPTT utilizing the microfluidic disk analyzer and the instrument used in hospitals. The test results showed good correlation and agreement between the two instruments. PMID:25332733

  14. Determination of element composition and extraterrestrial material occurrence in moss and lichen samples from King George Island (Antarctica) using reactor neutron activation analysis and SEM microscopy.

    PubMed

    Mróz, Tomasz; Szufa, Katarzyna; Frontasyeva, Marina V; Tselmovich, Vladimir; Ostrovnaya, Tatiana; Kornaś, Andrzej; Olech, Maria A; Mietelski, Jerzy W; Brudecki, Kamil

    2018-01-01

    Seven lichens (Usnea antarctica and U. aurantiacoatra) and nine moss samples (Sanionia uncinata) collected in King George Island were analyzed using instrumental neutron activation analysis, and concentration of major and trace elements was calculated. For some elements, the concentrations observed in moss samples were higher than corresponding values reported from other sites in the Antarctica, but in the lichens, these were in the same range of concentrations. Scanning electron microscopy (SEM) and statistical analysis showed large influence of volcanic-origin particles. Also, the interplanetary cosmic particles (ICP) were observed in investigated samples, as mosses and lichens are good collectors of ICP and micrometeorites.

  15. Could cash and good parenting affect child cognitive development? A cross-sectional study in South Africa and Malawi.

    PubMed

    Sherr, Lorraine; Macedo, Ana; Tomlinson, Mark; Skeen, Sarah; Cluver, Lucie Dale

    2017-05-12

    Social protection interventions, including cash grants and care provision have been shown to effectively reduce some negative impacts of the HIV epidemic on adolescents and families. Less is known about the role of social protection on younger HIV affected populations. This study explored the impact of cash grants on children's cognitive development. Additionally, we examined whether combined cash and care (operationalised as good parenting) was associated with improved cognitive outcomes. The sample included 854 children, aged 5 - 15, participating in community-based organisation (CBO) programmes for children affected by HIV in South Africa and Malawi. Data on child cognitive functioning were gathered by a combination of caregiver report and observer administered tests. Primary caregivers also reported on the economic situation of the family, cash receipt into the home, child and household HIV status. Parenting was measured on a 10 item scale with good parenting defined as a score of 8 or above. About half of families received cash (55%, n = 473), only 6% (n = 51) reported good parenting above the cut-off point but no cash, 18% (n = 151) received combined cash support and reported good parenting, and 21% (n = 179) had neither. Findings show that cash receipt was associated with enhanced child cognitive outcomes in a number of domains including verbal working memory, general cognitive functioning, and learning. Furthermore, cash plus good parenting provided an additive effect. Child HIV status had a moderating effect on the association between cash or/plus good parenting and cognitive outcomes. The association between cash and good parenting and child cognitive outcomes remained significant among both HIV positive and negative children, but overall the HIV negative group benefited more. This study shows the importance of cash transfers and good parenting on cognitive development of young children living in HIV affected environments. Our data clearly indicate that combined provision (cash plus good parenting) have added value.

  16. Molecularly imprinted polymer microspheres prepared by Pickering emulsion polymerization for selective solid-phase extraction of eight bisphenols from human urine samples.

    PubMed

    Yang, Jiajia; Li, Yun; Wang, Jincheng; Sun, Xiaoli; Cao, Rong; Sun, Hao; Huang, Chaonan; Chen, Jiping

    2015-05-04

    The bisphenol A (BPA) imprinted polymer microspheres were prepared by simple Pickering emulsion polymerization. Compared to traditional bulk polymerization, both high yields of polymer and good control of particle sizes were achieved. The characterization results of scanning electron microscopy and nitrogen adsorption-desorption measurements showed that the obtained molecularly imprinted polymer microsphere (MIPMS) particles possessed regular spherical shape, narrow diameter distribution (30-60 μm), a specific surface area (S(BET)) of 281.26 m(2) g(-1) and a total pore volume (V(t)) of 0.459 cm(3) g(-1). Good specific adsorption capacity for BPA was obtained in the sorption experiment and good class selectivity for BPA and its seven structural analogs (bisphenol F, bisphenol B, bisphenol E, bisphenol AF, bisphenol S, bisphenol AP and bisphenol Z) was demonstrated by the chromatographic evaluation experiment. The MIPMS as solid-phase extraction (SPE) packing material was then evaluated for extraction and clean-up of these bisphenols (BPs) from human urine samples. An accurate and sensitive analytical method based on the MIPMS-SPE coupled with HPLC-DAD has been successfully established for simultaneous determination of eight BPs from human urine samples with detection limits of 1.2-2.2 ng mL(-1). The recoveries of BPs for urine samples at two spiking levels (100 and 500 ng mL(-1) for each BP) were in the range of 81.3-106.7% with RSD values below 8.3%. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Assessing quality of life in severe obesity: development and psychometric properties of the ORWELL-R.

    PubMed

    Camolas, José; Ferreira, André; Mannucci, Edoardo; Mascarenhas, Mário; Carvalho, Manuel; Moreira, Pedro; do Carmo, Isabel; Santos, Osvaldo

    2016-06-01

    Several health-related quality-of-life (HRQoL) dimensions are affected by obesity. Our goal was to characterize the psychometric properties of the ORWELL-R, a new obesity-related quality-of-life instrument for assessing the "individual experience of overweightness". This psychometric assessment included two different samples: one multicenter clinical sample, used for assessing internal consistency, construct validity and temporal reliability; and a community sample (collected through a cross-sectional mailing survey design), used for additional construct validity assessment and model fit confirmation. Overall, 946 persons participated (188 from the clinical sample; 758 from community sample). An alpha coefficient of 0.925 (clinical sample) and 0.934 (community sample) was found. Three subscales were identified (53.2 % of variance): Body environment experience (alpha = 0.875), Illness perception and distress (alpha = 0.864), Physical symptoms (alpha = 0.674). Adequate test-retest reliability has been confirmed (ICC: 0.78 for the overall score). ORWELL-R scores were worse in the clinical sample. Worst HRQoL, as measured by higher ORWELL-R scores, was associated with BMI increases. ORWELL-R scores were associated with IWQOL-Lite and lower scores in happiness. ORWELL-R shows good internal consistency and adequate test-retest reliability. Good construct validity was also observed (for convergent and discriminant validity) and confirmed through confirmatory factor analysis (in both clinical and community samples). Presented data sustain ORWELL-R as a reliable and useful instrument to assess obesity-related QoL, in both research and clinical contexts.

  18. Applications of chemiluminescence to bacterial analysis

    NASA Technical Reports Server (NTRS)

    Searle, N. D.

    1975-01-01

    Luminol chemiluminescence method for detecting bacteria was based on microbial activation of the oxidation of the luminol monoanion by hydrogen peroxide. Elimination of the prior lysing step, previously used in the chemiluminescence technique, was shown to improve considerably the reproducibility and accuracy of the method in addition to simplifying it. An inexpensive, portable photomultiplier detector was used to measure the maximum light intensity produced when the sample is added to the reagent. Studies of cooling tower water show that the luminol chemiluminescence technique can be used to monitor changes in viable cell population both under normal conditions and during chlorine treatment. Good correlation between chemiluminescence and plate counts was also obtained in the analysis of process water used in paper mills. This method showed good potential for monitoring the viable bacteria populations in activated sludge used in waste treatment plants to digest organic matter.

  19. Stability of urine specimens stored with and without preservatives at room temperature and on ice prior to urinalysis.

    PubMed

    Ercan, Müjgan; Akbulut, Emiş Deniz; Abuşoğlu, Sedat; Yılmaz, Fatma Meriç; Oğuz, Esra Fırat; Topçuoğlu, Canan; Öztekin, Volkan; Boğdaycıoğlu, Nihal

    2015-09-01

    Laboratories determine the most appropriate approach for the collection and transport of urine specimens. We investigated the effect of a chlorhexidine-based preservative tube on sample stability, compared the results of refrigerated polystyrene tubes with no additives, and investigated the effect of temperature on the performance of preservative tubes. Fresh urine specimen (n=48) aliquots in BD Vacutainer® Plus Urinalysis Preservative Tubes and polystyrene tubes were analyzed on an Iris Diagnostics iQ200. Samples in polystyrene tubes were refrigerated for 4 and 8h. Four aliquots in preservative tubes were kept at room temperature for 4, 8, 24, and 72h, while two aliquots were kept on ice for 4 and 8h. There was good agreement for all chemistry and microscopy parameters with the exceptions of white blood cells (WBCs) at 24 and 72h and red blood cells (RBCs) at 72h. Preservative tubes on ice showed a significant decrease in concordance of WBCs and calcium oxalate (CaOx) parameters compared with the results at room temperature. Results of refrigerated polystyrene tubes showed good agreement with the exceptions of WBC clumps and amorphous crystal at 8h. A chlorhexidine-containing preservative tube seems advantageous for urine sample transport from outside healthcare services. A preservative tube offers comparable results with urine samples kept in a refrigerator for 4-8h for the majority of parameters. Keeping samples at room temperature is recommended when preservative tubes are used because ice produces a negative effect on WBCs and CaOx. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. Displacement imprinted polymer receptor analysis (DIPRA) for chlorophenolic contaminants in drinking water and packaging materials.

    PubMed

    Nicholls, C; Karim, K; Piletsky, S; Saini, S; Setford, S

    2006-01-15

    The preparation of a molecularly imprinted polymer (MIP) for pentachlorophenol is described together with two alternative reporter derivatives for use in a displacement imprinted polymer receptor analysis (DIPRA) format procedure. In this procedure, alternative reporter molecules were rebound to the synthetic receptor sites and their displacement by the target analyte was employed as the basis of a simple procedure for the measurement of chlorophenols in water and packaging material samples. Water samples were extracted using the standard procedure (EPA 528) and a detection limit of 0.5 microg l(-1) was achieved using the DIPRA detection method, with good agreement between the displacement technique and GC-ECD analysis. A variety of packaging materials, extracted using a buffered detergent solution were also analysed using the DIPRA procedure and showed good agreement with GC results. In addition, investigation of the cross-reactivity of a range of pesticides and materials commonly encountered in environmental analysis indicated the procedure gave good discrimination between pesticides bearing a chlorophenolic moiety and other materials. The procedure is considered highly suitable for use as a rapid field-test method or for incorporation into a test kit device.

  1. Good and Bad Sleep in Childhood: A Questionnaire Survey amongst School Children in Southern Italy

    PubMed Central

    Ficca, Gianluca; Conte, Francesca; De Padova, Vittoria; Zilli, Iole

    2011-01-01

    Despite its clinical importance, the issue of subjective sleep quality in children remains unexplored. Here we investigate, in school-aged children, the prevalence of bad sleep perception and its relationships with sleep habits and daytime functioning, to provide hints on its possible determinants. Subjective sleep perception, sleep habits, and daytime functioning were studied through a questionnaire survey in a sample of 482 children (6–12 yrs.). Being “bad sleeper” was reported by 6.9% of the sample. Compared to the “good sleepers”, these subjects displayed shorter sleep duration on schooldays, longer sleep latencies, and a more pronounced evening preference, beyond more frequent insufficient sleep. Though no differences emerged in sleepiness, bad sleepers showed higher impairments in daytime functioning, indicated by more frequent depressed mood and impulsivity. These distinctive features might be very important to precociously detect those children who are possibly more vulnerable to sleep disturbances and whose sleep-wake rhythms evolution should be paid particular attention thereafter. “The good people sleep much better at night than the bad people. Of course, the bad people enjoy the waking hours much more” Woody Allen PMID:23509633

  2. Optimal weighting in fNL constraints from large scale structure in an idealised case

    NASA Astrophysics Data System (ADS)

    Slosar, Anže

    2009-03-01

    We consider the problem of optimal weighting of tracers of structure for the purpose of constraining the non-Gaussianity parameter fNL. We work within the Fisher matrix formalism expanded around fiducial model with fNL = 0 and make several simplifying assumptions. By slicing a general sample into infinitely many samples with different biases, we derive the analytic expression for the relevant Fisher matrix element. We next consider weighting schemes that construct two effective samples from a single sample of tracers with a continuously varying bias. We show that a particularly simple ansatz for weighting functions can recover all information about fNL in the initial sample that is recoverable using a given bias observable and that simple division into two equal samples is considerably suboptimal when sampling of modes is good, but only marginally suboptimal in the limit where Poisson errors dominate.

  3. CO₂ adsorption on amine-functionalized periodic mesoporous benzenesilicas.

    PubMed

    Sim, Kyohyun; Lee, Nakwon; Kim, Joonseok; Cho, Eun-Bum; Gunathilake, Chamila; Jaroniec, Mietek

    2015-04-01

    CO2 adsorption was investigated on amine-functionalized mesoporous silica (SBA-15) and periodic mesoporous organosilica (PMO) samples. Hexagonally (p6mm) ordered mesoporous SBA-15 and benzene-PMO (BPMO) samples were prepared in the presence of Pluronic P123 block copolymer template under acidic conditions. Three kinds of amine-containing organosilanes and polyethylenimine were used to functionalize SBA-15 and BPMO. Small-angle X-ray scattering and nitrogen adsorption isotherms showed that these samples featured ordered mesostructure, high surface area, and narrow pore size distributions. Solid-state (13)C- and (29)Si cross-polarization magic-angle spinning NMR spectra showed chemical linkage between amine-containing modifiers and the surface of mesoporous materials. The chemically linked amine-containing modifiers were found to be on both the inner and outer surfaces. N-[3-(trimethoxysilyl)propyl]ethylenediamine-modified BPMO (A2-BPMO) sample exhibited the highest CO2 uptake (i.e., ∼3.03 mmol/g measured on a volumetric adsorption analyzer) and the fastest adsorption rate (i.e., ∼13 min to attain 90% of the maximum amount) among all the samples studied. Selectivity and reproducibility measurements for the A2-BPMO sample showed quite good performance in flowing N2 gas at 40 mL/min and CO2 gas of 60 mL/min at 25 °C.

  4. The Measurement Structure, Stability and Mediating Effects of Achievement Goals in Math with Middle-School Student Data

    ERIC Educational Resources Information Center

    Chiang, Yu-Tzu; Lin, Sunny S. J.

    2014-01-01

    This study examined the measurement structure, cross-year stability of achievement goals, and mediating effects of achievement goals between self-efficacy and math grades in a national sample of Taiwan middle school students. The measurement model with factorial structure showed good fit to the data. In the panel data (N?=?343), four achievement…

  5. Twelve-year acorn yield in Southern Appalachian Oaks

    Treesearch

    Donald E. Beck

    1977-01-01

    A 12-year sample from Southern Appalachian oak stands showed acorns to be a valuable though inconsistent source of wildlife food. At least moderate amounts of acorns were produced in 9 of the years, with 4 years being exceptionally good. In 3 of the years, acorn production was very low. There were distinct differences in the production of acorns by the five species...

  6. Enhanced antioxidation and microwave absorbing properties of SiO2-coated flaky carbonyl iron particles

    NASA Astrophysics Data System (ADS)

    Zhou, Yingying; Xie, Hui; Zhou, Wancheng; Ren, Zhaowen

    2018-01-01

    SiO2 was successfully coated on the surface of flaky carbonyl iron particles using a chemical bath deposition method in the presence of 3-aminopropyl triethoxysilane (APTES). The morphologies, composition, valence states of elements, as well as antioxidation and electromagnetic properties of the samples were characterized by scanning electron microscope (SEM), energy dispersive spectrometer (EDS), X-ray photoelectron spectroscopy (XPS), thermogravimetric (TG) and microwave network analyzer. TG curve shows the obvious weight gain of carbonyl iron was deferred to 360 °C after SiO2-coated, which can be ascribed to the exits of SiO2 overlayer. Compared with the raw carbonyl iron, SiO2-coated sample shows good wave absorption performance due to its impedance matching. The electromagnetic properties of raw and SiO2-coated carbonyl iron particles were characterized in X band before and after heat treatment at 250 °C for 10 h. It was established that SiO2-coated carbonyl iron demonstrate good thermal stability, indicating SiO2-coating is useful in the usage of microwave absorbers operating at temperature up to 250 °C.

  7. Effect of sample preparation method on quantification of polymorphs using PXRD.

    PubMed

    Alam, Shahnwaz; Patel, Sarsvatkumar; Bansal, Arvind Kumar

    2010-01-01

    The purpose of this study was to improve the sensitivity and accuracy of quantitative analysis of polymorphic mixtures. Various techniques such as hand grinding and mixing (in mortar and pestle), air jet milling and ball milling for micronization of particle and mixing were used to prepare binary mixtures. Using these techniques, mixtures of form I and form II of clopidogrel bisulphate were prepared in various proportions from 0-5% w/w of form I in form II and subjected to x-ray powder diffraction analysis. In order to obtain good resolution in minimum time, step time and step size were varied to optimize scan rate. Among the six combinations, step size of 0.05 degrees with step time of 5 s demonstrated identification of maximum characteristic peaks of form I in form II. Data obtained from samples prepared using both grinding and mixing in ball mill showed good analytical sensitivity and accuracy compared to other methods. Powder x-ray diffraction method was reproducible, precise with LOD of 0.29% and LOQ of 0.91%. Validation results showed excellent correlation between actual and predicted concentration with R2 > 0.9999.

  8. Quantum transport in chaotic and integrable ballistic cavities with tunable shape

    NASA Astrophysics Data System (ADS)

    Lee, Y.; Faini, G.; Mailly, D.

    1997-10-01

    We have performed magnetotransport measurements in ballistic cavities and obtained the average by small modulations on the shapes and/or on the Fermi level. We work with cavities whose underlying classical dynamics is chaotic (stadia and Sinaï billiards) and integrable (circles and rectangles). The former show a Lorentzian weak-localization peak, in agreement with semiclassical predictions and other averaging methods that have been used in recent measurements. For integrable cavities our measurements show that the shape of the weak localization is very sensitive to the exact geometry of the sample: a linear magnetoconductance has been observed for rectangles as expected by the theory for integrable cavities, whereas for circles the shape is always Lorentzian. These discrepancies illustrate the nongeneric behavior of scattering through integrable geometries, that we analyze taking into account the interplay of integrability with smooth disorder and geometrical effects. The power spectra of the conductance fluctuations are also analyzed, the deduced typical areas are in good agreement with those obtained from the weak localization. Periodic orbits in nonaveraged Fourier transforms of the magnetoconductance for regular cavities are clearly identified indicating the good quality of our samples.

  9. In vivo degradation of polyurethane foam with 55 wt % polyethylene glycol.

    PubMed

    Broekema, Ferdinand I; Van Leeuwen, M Barbara M; Van Minnen, Baucke; Bos, Rudolf R M

    2015-11-01

    Most topical hemostatic agents are based on animal-derived products like collagen and gelatin. They carry the potential risk of pathogen transmission while adjustments in the production process of these materials are limited. A synthetic hemostatic agent based on polyurethane (PU) and polyethylene glycol (PEG) was developed to overcome these disadvantages. The goal of this study was to compare the degradation process of this biomaterial to collagen and gelatin hemostatic agents. Samples of the test materials were implanted subcutaneously in both rats and rabbits. The animals were sacrificed at certain time intervals up to three years and the explanted samples were microscopically assessed. The histological examination showed a comparable pattern of degradation for the different test materials. Remnants of gelatin and collagen were seen up to 26 and 39 weeks, respectively. For PU, it took up to three years before micro-particles of the material were no longer detected. All biomaterials showed a good biocompatibility and no severe foreign body reactions occurred. The good biocompatibility and predictable pattern of resorption indicate that PU can be used as a topical hemostatic agent. However, a degradation time comparable to collagen and gelatin would be favorable. © 2015 Wiley Periodicals, Inc.

  10. Good Self-Control as a Buffering Agent for Adolescent Substance Use

    PubMed Central

    Wills, Thomas A.; Ainette, Michael G.

    2008-01-01

    We tested the prediction that self-control will have buffering effects for adolescent substance use (tobacco, alcohol, and marijuana) with regard to three risk factors: family life events, adolescent life events, and peer substance use. Participants were a sample of public school students (N = 1,767) who were surveyed at four yearly intervals between 6th grade and 9th grade. Good self-control was assessed with multiple indicators including planning and problem solving. Results showed that the impact of all three risk factors on substance use was reduced among persons with higher scores on good self-control. Buffering was found in cross-sectional analyses with multiple regression and in longitudinal analyses in a latent growth model with time-varying covariates. Implications for addressing self-control in prevention programs are discussed. PMID:19071971

  11. End-of-Kindergarten Spelling Outcomes: How Can Spelling Error Analysis Data Inform Beginning Reading Instruction?

    PubMed Central

    Lee, Julia Ai Cheng; Otaiba, Stephanie Al

    2016-01-01

    In this article, the authors examined the spelling performance of 430 kindergarteners, which included a high risk sample, to determine the relations between end of kindergarten reading and spelling in a high quality language arts setting. The spelling outcomes including the spelling errors between the good and the poor readers were described, analyzed, and compared. The findings suggest that not all the children have acquired the desired standard as outlined by the Common Core State Standards. In addition, not every good reader is a good speller and that not every poor speller is a poor reader. The study shows that spelling tasks that are accompanied by spelling errors analysis provide a powerful window for making instructional sense of children’s spelling errors and for individualizing spelling instructional strategies. PMID:28706433

  12. Chemical Characterization of an Envelope B/D Sample from Hanford Tank 241-AZ-102

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hay, M.S.

    2000-08-23

    A sample from Hanford waste tank 241-AZ-102 was received at the Savannah River Technology Center (SRTC) and chemically characterized. The sample containing supernate and a small amount of sludge solids was analyzed as-received. The filtered supernatant liquid, the total dried solids of the sample, and the washed insoluble solids obtained from filtration of the sample were analyzed. A mass balance calculation of the three fractions of the sample analyzed indicate the analytical results appear relatively self-consistent for major components of the sample. However, some inconsistency was observed between results were more than one method of determination was employed and formore » species present in low concentrations. The actinides isotopes, plutonium, americium, and curium, present analytical challenges due to the low concentration of these species and the potential for introduction of small amounts of contamination during sampling handling resulting in large uncertainties. A direct comparison to previous analyses of material from tank 241-AZ-102 showed good agreement with the filtered supernatant liquid. However, the comparison of solids data showed poor agreement. The poor agreement shown between the current results for the solids samples and previous analyses most likely results from the uncertainties associated with obtaining small solids samples from a large non-homogenized waste tank.« less

  13. Looking Good or Being Good? The Role of Social Desirability Tendencies in Student Perceptions of Institutional Mission and Values

    ERIC Educational Resources Information Center

    Ferrari, Joseph R.; Bristow, Maya; Cowman, Shaun E.

    2005-01-01

    Two samples of college students (Sample 1, n = 106 Sample 2, n = 107) completed self-report measures that assessed their perceptions of their university's mission and values along with their tendency to seek social approval. With Sample 1, global social desirability was not predictive of any student perceptions related to institutional mission and…

  14. Detection of Thrombin Based on Fluorescence Energy Transfer between Semiconducting Polymer Dots and BHQ-Labelled Aptamers.

    PubMed

    Liu, Yizhang; Jiang, Xuekai; Cao, Wenfeng; Sun, Junyong; Gao, Feng

    2018-02-14

    Carboxyl-functionalized semiconducting polymer dots (Pdots) were synthesized as an energy donor by the nanoprecipitation method. A black hole quenching dye (BHQ-labelled thrombin aptamers) was used as the energy acceptor, and fluorescence resonance energy transfer between the aptamers and Pdots was used for fluorescence quenching of the Pdots. The addition of thrombin restored the fluorescence intensity. Under the optimized experimental conditions, the fluorescence of the system was restored to the maximum when the concentration of thrombin reached 130 nM, with a linear range of 0-50 nM (R² = 0.990) and a detection limit of 0.33 nM. This sensor was less disturbed by impurities, showing good specificity and signal response to thrombin, with good application in actual samples. The detection of human serum showed good linearity in the range of 0-30 nM (R² = 0.997), with a detection limit of 0.56 nM and a recovery rate of 96.2-104.1%, indicating that this fluorescence sensor can be used for the detection of thrombin content in human serum.

  15. Lactoferrin-Immobilized Surfaces onto Functionalized PLA Assisted by the Gamma-Rays and Nitrogen Plasma to Create Materials with Multifunctional Properties.

    PubMed

    Stoleru, Elena; Zaharescu, Traian; Hitruc, Elena Gabriela; Vesel, Alenka; Ioanid, Emil G; Coroaba, Adina; Safrany, Agnes; Pricope, Gina; Lungu, Maria; Schick, Christoph; Vasile, Cornelia

    2016-11-23

    Both cold nitrogen radiofrequency plasma and gamma irradiation have been applied to activate and functionalize the polylactic acid (PLA) surface and the subsequent lactoferrin immobilization. Modified films were comparatively characterized with respect to the procedure of activation and also with unmodified sample by water contact angle measurements, mass loss, X-ray photoelectron spectroscopy (XPS), attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR), atomic force microscopy (AFM), and chemiluminescence measurements. All modified samples exhibit enhanced surface properties mainly those concerning biocompatibility, antimicrobial, and antioxidant properties, and furthermore, they are biodegradable and environmentally friendly. Lactoferrin deposited layer by covalent coupling using carbodiimide chemistry showed a good stability. It was found that the lactoferrin-modified PLA materials present significantly increased oxidative stability. Gamma-irradiated samples and lactoferrin-functionalized samples show higher antioxidant, antimicrobial, and cell proliferation activity than plasma-activated and lactoferrin-functionalized ones. The multifunctional materials thus obtained could find application as biomaterials or as bioactive packaging films.

  16. Direct Compositional Characterization of (U,Th)O2 Powders, Microspheres, and Pellets Using TXRF.

    PubMed

    Dhara, Sangita; Prabhat, Parimal; Misra, N L

    2015-10-20

    A total reflection X-ray fluorescence (TXRF) analysis method for direct compositional characterization of sintered and green (U,Th)O2 samples in different forms (e.g., pellets, powders, and microspheres) without sample dissolution has been developed for the first time. The methodology involves transfer of only a few nanograms of the sample on the TXRF sample support by gently rubbing the samples on supports or taking their tiny uniform slurry in collodion on the sample support, drying them to make thin film, and measuring the TXRF spectra of the specimens thus prepared. This approach minimizes the matrix effects. Uranium determinations from the TXRF spectra of such specimens were made with respect to thorium, considering it as an internal standard. Samples having uranium atom percent (at%) from 0 to 100 in (U,Th)O2 were analyzed for uranium in comparison to thorium. The results showed an average precision of 2.6% (RSD, 2σ, n = 8). The TXRF-determined results deviated from expected values within 5%. The TXRF results were compared with those of biamperometry with good agreement. The lattice parameters of the solid solutions were calculated using their XRD patterns. A good correlation between lattice parameters and TXRF-determined U at% and between TXRF-determined U at% and expected U at%, calculated on the basis of preparation of (U,Th)O2 solid solutions, was obtained. The developed method is capable of analyzing (U,Th)O2 samples directly with almost negligible sample preparation and is well suited for radioactive samples. The present study suggests that this method can be extended for the determination of U,Th and Pu in other nuclear fuel materials (e.g., nitrides, carbides, etc.) in the form of pellets, powders, and microspheres after suitable modifications in sample handling procedure.

  17. Minor corral changes and adoption of good handling practices can improve the behavior and reduce cortisol release in Nellore cows.

    PubMed

    Lima, Maria Lúcia Pereira; Negrão, João Alberto; de Paz, Claudia Cristina Paro; Grandin, Temple

    2018-03-01

    Inadequate corral facilities and improper handling are major causes of stress in beef cattle. The purpose of this study was to evaluate the effects of minor changes in the corral and adoption of good handling practices on the behavior, cortisol release, and time spent taking blood samples in Nellore cows. Minor corral changes included obstructing the cow's vision when the handler walked deep into the animal's flight zone and the elimination of bright objects, color contrasts, puddles, shadows, and darkness in the corral. Handling was improved by eliminating dogs, electric goads (prods), and yelling, as well as adopting a calm behavior. A total of 141 Nellore cows from two typical extensive livestock farms were studied. The cows were evaluated individually before and after the corral changes. Blood samples were collected in the restraint device for cortisol measurement. The minor corral changes and the adoption of good handling practices result in better results for all variables studied. The results showed differences in the interactions between treatment and ranch for chute score (P = 0.0091) and exit score (P < 0.0001). The cortisol release was lower (P < 0.001) and better for the improved methods, resulting in calmer cows compared to cortisol released before the minor changes (41.03 ± 2.9 vs 60.40 ± 3.8 ng/mL). Minor changes made in the corrals and the adoption of good handling practices were effective in improving cow behavior in the chute and in reducing exit velocity, cortisol released, and the time spent taking blood samples.

  18. Electrochemical As(III) whole-cell based biochip sensor.

    PubMed

    Cortés-Salazar, Fernando; Beggah, Siham; van der Meer, Jan Roelof; Girault, Hubert H

    2013-09-15

    The development of a whole-cell based sensor for arsenite detection coupling biological engineering and electrochemical techniques is presented. This strategy takes advantage of the natural Escherichia coli resistance mechanism against toxic arsenic species, such as arsenite, which consists of the selective intracellular recognition of arsenite and its pumping out from the cell. A whole-cell based biosensor can be produced by coupling the intracellular recognition of arsenite to the generation of an electrochemical signal. Hereto, E. coli was equipped with a genetic circuit in which synthesis of beta-galactosidase is under control of the arsenite-derepressable arsR-promoter. The E. coli reporter strain was filled in a microchip containing 16 independent electrochemical cells (i.e. two-electrode cell), which was then employed for analysis of tap and groundwater samples. The developed arsenic-sensitive electrochemical biochip is easy to use and outperforms state-of-the-art bacterial bioreporters assays specifically in its simplicity and response time, while keeping a very good limit of detection in tap water, i.e. 0.8ppb. Additionally, a very good linear response in the ranges of concentration tested (0.94ppb to 3.75ppb, R(2)=0.9975 and 3.75 ppb to 30ppb, R(2)=0.9991) was obtained, complying perfectly with the acceptable arsenic concentration limits defined by the World Health Organization for drinking water samples (i.e. 10ppb). Therefore, the proposed assay provides a very good alternative for the portable quantification of As (III) in water as corroborated by the analysis of natural groundwater samples from Swiss mountains, which showed a very good agreement with the results obtained by atomic absorption spectroscopy. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Puckering free energy of pyranoses: A NMR and metadynamics-umbrella sampling investigation

    NASA Astrophysics Data System (ADS)

    Autieri, E.; Sega, M.; Pederiva, F.; Guella, G.

    2010-09-01

    We present the results of a combined metadynamics-umbrella sampling investigation of the puckered conformers of pyranoses described using the GROMOS 45a4 force field. The free energy landscape of Cremer-Pople puckering coordinates has been calculated for the whole series of α and β aldohexoses, showing that the current force field parameters fail in reproducing proper puckering free energy differences between chair conformers. We suggest a modification to the GROMOS 45a4 parameter set which improves considerably the agreement of simulation results with theoretical and experimental estimates of puckering free energies. We also report on the experimental measurement of altrose conformer populations by means of NMR spectroscopy, which show good agreement with the predictions of current theoretical models.

  20. DBS-LC-MS/MS assay for caffeine: validation and neonatal application.

    PubMed

    Bruschettini, Matteo; Barco, Sebastiano; Romantsik, Olga; Risso, Francesco; Gennai, Iulian; Chinea, Benito; Ramenghi, Luca A; Tripodi, Gino; Cangemi, Giuliana

    2016-09-01

    DBS might be an appropriate microsampling technique for therapeutic drug monitoring of caffeine in infants. Nevertheless, its application presents several issues that still limit its use. This paper describes a validated DBS-LC-MS/MS method for caffeine. The results of the method validation showed an hematocrit dependence. In the analysis of 96 paired plasma and DBS clinical samples, caffeine levels measured in DBS were statistically significantly lower than in plasma but the observed differences were independent from hematocrit. These results clearly showed the need for extensive validation with real-life samples for DBS-based methods. DBS-LC-MS/MS can be considered to be a good alternative to traditional methods for therapeutic drug monitoring or PK studies in preterm infants.

  1. Pipeline for large-scale microdroplet bisulfite PCR-based sequencing allows the tracking of hepitype evolution in tumors.

    PubMed

    Herrmann, Alexander; Haake, Andrea; Ammerpohl, Ole; Martin-Guerrero, Idoia; Szafranski, Karol; Stemshorn, Kathryn; Nothnagel, Michael; Kotsopoulos, Steve K; Richter, Julia; Warner, Jason; Olson, Jeff; Link, Darren R; Schreiber, Stefan; Krawczak, Michael; Platzer, Matthias; Nürnberg, Peter; Siebert, Reiner; Hampe, Jochen

    2011-01-01

    Cytosine methylation provides an epigenetic level of cellular plasticity that is important for development, differentiation and cancerogenesis. We adopted microdroplet PCR to bisulfite treated target DNA in combination with second generation sequencing to simultaneously assess DNA sequence and methylation. We show measurement of methylation status in a wide range of target sequences (total 34 kb) with an average coverage of 95% (median 100%) and good correlation to the opposite strand (rho = 0.96) and to pyrosequencing (rho = 0.87). Data from lymphoma and colorectal cancer samples for SNRPN (imprinted gene), FGF6 (demethylated in the cancer samples) and HS3ST2 (methylated in the cancer samples) serve as a proof of principle showing the integration of SNP data and phased DNA-methylation information into "hepitypes" and thus the analysis of DNA methylation phylogeny in the somatic evolution of cancer.

  2. Influence of the pore fluid on the phase velocity in bovine trabecular bone In Vitro: Prediction of the biot model

    NASA Astrophysics Data System (ADS)

    Lee, Kang Il

    2013-01-01

    The present study aims to investigate the influence of the pore fluid on the phase velocity in bovine trabecular bone in vitro. The frequency-dependent phase velocity was measured in 20 marrow-filled and water-filled bovine femoral trabecular bone samples. The mean phase velocities at frequencies between 0.6 and 1.2 MHz exhibited significant negative dispersions for both the marrow-filled and the water-filled samples. The magnitudes of the dispersions showed no significant differences between the marrow-filled and the water-filled samples. In contrast, replacement of marrow by water led to a mean increase in the phase velocity of 27 m/s at frequencies from 0.6 to 1.2 MHz. The theoretical phase velocities of the fast wave predicted by using the Biot model for elastic wave propagation in fluid-saturated porous media showed good agreements with the measurements.

  3. Determination of Tryptamines and β-Carbolines in Ayahuasca Beverage Consumed During Brazilian Religious Ceremonies.

    PubMed

    Santos, Mônica Cardoso; Navickiene, Sandro; Gaujac, Alain

    2017-05-01

    Ayahuasca is a potent hallucinogenic beverage prepared from Banisteriopsis caapi in combination with other psychoactive plants. N,N-dimethyltryptamine, tryptamine, harmine, harmaline, harmalol, and tetrahydroharmine were quantified in ayahuasca samples using a simple and low-cost method based on SPE and LC with UV diode-array detection. The experimental variables that affect the SPE method, such as type of solid phase and nature of solvent, were optimized. The method showed good linearity (r > 0.9902) and repeatability (RSD < 0.8%) for alkaloid compounds, with an LOD of 0.12 mg/L. The proposed method was used to analyze 20 samples from an ayahuasca cooking process from a religious group located in the municipality of Fortaleza, state of Ceará, Brazil. The results showed that concentrations of the target compounds ranged from 0.3 to 36.7 g/L for these samples.

  4. Gentamicin-Eluting Titanium Dioxide Nanotubes Grown on the Ultrafine-Grained Titanium.

    PubMed

    Nemati, Sima Hashemi; Hadjizadeh, Afra

    2017-08-01

    Titanium (Ti)-based materials is the most appropriate choices for the applications as orthopedic and dental implants. In this regard, ultrafine-grained (UFG) titanium with an enhanced mechanical properties and surface energy has attracted more attention. Titanium dioxide (TiO 2 ) nanotubes grown on the titanium could enhance bone bonding, cellular response and are good reservoirs for loading drugs and antibacterial agents. This article investigates gentamicin loading into and release from the TiO 2 nanotubes, grown on the UFG compared to coarse-grained (CG) titanium substrate surfaces. Equal Channel Angular Pressing (ECAP) was employed to produce the UFG structure titanium. TiO 2 nanotubes were grown by the anodizing technique on both UFG and CG titanium substrate surfaces. Scanning electron microscopy (SEM) imaging confirmed TiO 2 nanotube growth on the surface. The UV-vis spectroscopy analysis results show that the amount of gentamicin load-release in the anodized UFG titanium sample is higher than that of CG one which can be explained in terms of thicker TiO 2 nanotube arrays layer formed on UFG sample. Moreover, the anodized UFG titanium samples released the drug in a longer time than CG (1 day for the UFG titanium vs. 3 h for the CG one). Regarding wettability analysis, anodized UFG titanium sample showed more enhanced hydrophilicity than CG counterpart. Therefore, the significantly smaller grain size of pure titanium provided by the ECAP technique coupled with appropriate subsequent anodization treatment not only offers a good combination of biocompatibility and adequate mechanical properties but also it provides a delayed release condition for gentamicin.

  5. Performance of the score systems Acute Physiology and Chronic Health Evaluation II and III at an interdisciplinary intensive care unit, after customization

    PubMed Central

    Markgraf, Rainer; Deutschinoff, Gerd; Pientka, Ludger; Scholten, Theo; Lorenz, Cristoph

    2001-01-01

    Background: Mortality predictions calculated using scoring scales are often not accurate in populations other than those in which the scales were developed because of differences in case-mix. The present study investigates the effect of first-level customization, using a logistic regression technique, on discrimination and calibration of the Acute Physiology and Chronic Health Evaluation (APACHE) II and III scales. Method: Probabilities of hospital death for patients were estimated by applying APACHE II and III and comparing these with observed outcomes. Using the split sample technique, a customized model to predict outcome was developed by logistic regression. The overall goodness-of-fit of the original and the customized models was assessed. Results: Of 3383 consecutive intensive care unit (ICU) admissions over 3 years, 2795 patients could be analyzed, and were split randomly into development and validation samples. The discriminative powers of APACHE II and III were unchanged by customization (areas under the receiver operating characteristic [ROC] curve 0.82 and 0.85, respectively). Hosmer-Lemeshow goodness-of-fit tests showed good calibration for APACHE II, but insufficient calibration for APACHE III. Customization improved calibration for both models, with a good fit for APACHE III as well. However, fit was different for various subgroups. Conclusions: The overall goodness-of-fit of APACHE III mortality prediction was improved significantly by customization, but uniformity of fit in different subgroups was not achieved. Therefore, application of the customized model provides no advantage, because differences in case-mix still limit comparisons of quality of care. PMID:11178223

  6. Ex vivo characterization of normal and adenocarcinoma colon samples by Mueller matrix polarimetry.

    PubMed

    Ahmad, Iftikhar; Ahmad, Manzoor; Khan, Karim; Ashraf, Sumara; Ahmad, Shakil; Ikram, Masroor

    2015-05-01

    Mueller matrix polarimetry along with polar decomposition algorithm was employed for the characterization of ex vivo normal and adenocarcinoma human colon tissues by polarized light in the visible spectral range (425-725 nm). Six derived polarization metrics [total diattenuation (DT ), retardance (RT ), depolarization(ΔT ), linear diattenuation (DL), retardance (δ), and depolarization (ΔL)] were compared for normal and adenocarcinoma colon tissue samples. The results show that all six polarimetric properties for adenocarcinoma samples were significantly higher as compared to the normal samples for all wavelengths. The Wilcoxon rank sum test illustrated that total retardance is a good candidate for the discrimination of normal and adenocarcinoma colon samples. Support vector machine classification for normal and adenocarcinoma based on the four polarization properties spectra (ΔT , ΔL, RT ,and δ) yielded 100% accuracy, sensitivity, and specificity, while both DTa nd DL showed 66.6%, 33.3%, and 83.3% accuracy, sensitivity, and specificity, respectively. The combination of polarization analysis and given classification methods provides a framework to distinguish the normal and cancerous tissues.

  7. Development and validation of a triplex real-time PCR for rapid detection and specific identification of M. avium sub sp. paratuberculosis in faecal samples.

    PubMed

    Irenge, Léonid M; Walravens, Karl; Govaerts, Marc; Godfroid, Jacques; Rosseels, Valérie; Huygen, Kris; Gala, Jean-Luc

    2009-04-14

    A triplex real-time (TRT-PCR) assay was developed to ensure a rapid and reliable detection of Mycobacterium avium subsp. paratuberculosis (Map) in faecal samples and to allow routine detection of Map in farmed livestock and wildlife species. The TRT-PCR assay was designed using IS900, ISMAP02 and f57 molecular targets. Specificity of TRT-PCR was first confirmed on a panel of control mycobacterial Map and non-Map strains and on faecal samples from Map-negative cows (n=35) and from Map-positive cows (n=20). The TRT-PCR assay was compared to direct examination after Ziehl-Neelsen (ZN) staining and to culture on 197 faecal samples collected serially from five calves experimentally exposed to Map over a 3-year period during the sub-clinical phase of the disease. The data showed a good agreement between culture and TRT-PCR (kappa score=0.63), with the TRT-PCR limit of detection of 2.5 x 10(2)microorganisms/g of faeces spiked with Map. ZN agreement with TRT-PCR was not good (kappa=0.02). Sequence analysis of IS900 amplicons from three single IS900 positive samples confirmed the true Map positivity of the samples. Highly specific IS900 amplification suggests therefore that each single IS900 positive sample from experimentally exposed animals was a true Map-positive specimen. In this controlled experimental setting, the TRT-PCT was rapid, specific and displayed a very high sensitivity for Map detection in faecal samples compared to conventional methods.

  8. Hydrogen peroxide biosensor based on hemoglobin immobilized at graphene, flower-like zinc oxide, and gold nanoparticles nanocomposite modified glassy carbon electrode.

    PubMed

    Xie, Lingling; Xu, Yuandong; Cao, Xiaoyu

    2013-07-01

    In this work, a highly sensitive hydrogen peroxide (H2O2) biosensor based on immobilization of hemoglobin (Hb) at Au nanoparticles (AuNPs)/flower-like zinc oxide/graphene (AuNPs/ZnO/Gr) composite modified glassy carbon electrode (GCE) was constructed, where ZnO and Au nanoparticles were modified through layer-by-layer onto Gr/GCE. Flower-like ZnO nanoparticles could be easily prepared by adding ethanol to the precursor solution having higher concentration of hydroxide ions. The Hb/AuNPs/ZnO/Gr composite film showed a pair of well-defined, quasi-reversible redox peaks with a formal potential (E(0)) of -0.367 V, characteristic features of heme redox couple of Hb. The electron transfer rate constant (k(s)) of immobilized Hb was 1.3 s(-1). The developed biosensor showed a very fast response (<2 s) toward H2O2 with good sensitivity, wide linear range, and low detection limit of 0.8 μM. The fabricated biosensor showed interesting features, including high selectivity, acceptable stability, good reproducibility, and repeatability along with excellent conductivity, facile electron mobility of Gr, and good biocompatibility of ZnO and AuNPs. The fabrication method of this biosensor was simple and effective for determination of H2O2 in real samples with quick response, good sensitivity, high selectivity, and acceptable recovery. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. The influence of water vapor on atmospheric exchange measurements with an ICOS* based Laser absorption analyzer

    NASA Astrophysics Data System (ADS)

    Bunk, Rüdiger; Quan, Zhi; Wandel, Matthias; Yi, Zhigang; Bozem, Heiko; Kesselmeier, Jürgen

    2014-05-01

    Carbonyl sulfide and carbon monoxide are both atmospheric trace gases of high interest. Recent advances in the field of spectroscopy have enabled instruments that measure the concentration of the above and other trace gases very fast and with good precision. Increasing the effective path length by reflecting the light between two mirrors in a cavity, these instruments reach impressive sensitivities. Often it is possible to measure the concentration of more than one trace gas at the same time. The OCS/CO2 Analyzer by LGR (Los Gatos Research, Inc.) measures the concentration of water vapor [H2O], carbonyl sulfide [COS], carbon dioxide [CO2] and carbon monoxide [CO] simultaneously. For that the cavity is saturated with light, than the attenuation of light is measured as in standard absorption spectroscopy. The instrument proved to be very fast with good precision and to be able to detect even very low concentrations, especially for COS (as low as 30ppt in the case of COS). However, we observed a rather strong cross sensitivity to water vapor. Altering the water vapor content of the sampled air with two different methods led to a change in the perceived concentration of COS, CO and CO2. This proved especially problematic for enclosure (cuvette) measurements, where the concentrations of one of the above species in an empty cuvette are compared to the concentration of another cuvette containing a plant whose exchange of trace gases with the atmosphere is of interest. There, the plants transpiration leads to a large difference in water vapor content between the cuvettes and that in turn produces artifacts in the concentration differences between the cuvettes for the other above mentioned trace gases. For CO, simultaneous measurement with a UV-Emission Analyzer (AL 5002, Aerolaser) and the COS/CO Analyzer showed good agreement of perceived concentrations as long as the sample gas was dry and an increasing difference in perceived concentration when the sample gas was humidified. The difference in perceived CO concentration showed a clear correlation to the water vapor content in the sample air. For COS we could show that changes in water vapor also impacted on the perceived COS concentrations; the raise of the water vapor concentration would lead to an increasing underestimation of the COS concentration. Drying the air using a Nafion Dryer before entering the COS/CO Analyzer eliminated any water vapor induced artifacts and showed no adverse effects on the quality of the conducted measurements. *Integrated cavity output spectroscopy

  10. Analysis of free amino acids in Amur sturgeon by ultra-performance liquid chromatography using pre-column derivatization with 6-aminoquinolyl-carbamyl.

    PubMed

    Sun, Yanchun; Xu, Xianzhu; Mou, Zhenbo; Wang, Jing; Tan, Zhijun; Wu, Song

    2012-12-01

    A rapid, sensitive, and reliable ultra-performance liquid chromatography (UPLC) coupled with photodiode array detection method was developed for the amino acid analysis of Amur sturgeon (Acipenser schrenckii Brandt). The method uses minimal sample volume and automated online precolumn derivitization of amino acids with fluorescent 6-aminoquinolyl-carbamyl reagent. The chromatographic separation was achieved by UPLC, which used a column with 1.7 μm particle packing that enabled higher speed of analysis, peak capacity, greater resolution, and increased sensitivity. Amino acid derivatives obtained under optimal conditions were separated on a Waters UPLC BEH C(18) column with Acetonitrile-acetate buffer as mobile phase. Matrix effects were investigated and good linearities with correlation coefficients better than 0.9949 were obtained over a wide range of 5-1000 μmol/L for all amino acids. The simple sample preparation and minimal sample volume make the method useful for the quantitation of 17 amino acids in Amur sturgeon samples. It is concluded that a rapid and robust platform based on UPLC was established, and a total of 17 amino acids of Amur sturgeon were tentatively detected. This method showed good accuracy and repeatability that can be used for the quantification of amino acids in real samples. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Performance evaluation of the Abbott CELL-DYN Ruby and the Sysmex XT-2000i haematology analysers.

    PubMed

    Leers, M P G; Goertz, H; Feller, A; Hoffmann, J J M L

    2011-02-01

    Two mid-range haematology analysers (Abbott CELL-DYN Ruby and Sysmex XT-2000i) were evaluated to determine their analytical performance and workflow efficiency in the haematology laboratory. In total 418 samples were processed for determining equivalence of complete blood count (CBC) measurements, and 100 for reticulocyte comparison. Blood smears served for assessing the agreement of the differential counts. Inter-instrument agreement for most parameters was good although small numbers of discrepancies were observed. Systematic biases were found for mean cell volume, reticulocytes, platelets and mean platelet volume. CELL-DYN Ruby WBC differentials were obtained with all samples while the XT-2000i suppressed differentials partially or completely in 13 samples (3.1%). WBC subpopulation counts were otherwise in good agreement with no major outliers. Following first-pass CBC/differential analysis, 88 (21%) of XT-2000i samples required further analyser processing compared to 18 (4.3%) for the CELL-DYN Ruby. Smear referrals for suspected WBC/nucleated red blood cells and platelet abnormalities were indicated for 106 (25.4%) and 95 (22.7%) of the XT-2000i and CELL-DYN Ruby samples respectively. Flagging efficiencies for both analysers were found to be similar. The Sysmex XT-2000i and Abbott CELL-DYN Ruby analysers have broadly comparable analytical performance, but the CELL-DYN Ruby showed superior first-pass efficiency. © 2010 Blackwell Publishing Ltd.

  12. Comparison of laser ablation and dried solution aerosol as sampling systems in inductively coupled plasma mass spectrometry.

    PubMed

    Coedo, A G; Padilla, I; Dorado, M T

    2004-12-01

    This paper describes a study designed to determine the possibility of using a dried aerosol solution for calibration in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The relative sensitivities of tested materials mobilized by laser ablation and by aqueous nebulization were established, and the experimentally determined relative sensitivity factors (RSFs) were used in conjunction with aqueous calibration for the analysis of solid steel samples. To such a purpose a set of CRM carbon steel samples (SS-451/1 to SS-460/1) were sampled into an ICP-MS instrument by solution nebulization using a microconcentric nebulizer with membrane desolvating (D-MCN) and by laser ablation (LA). Both systems were applied with the same ICP-MS operating parameters and the analyte signals were compared. The RSF (desolvated aerosol response/ablated solid response) values were close to 1 for the analytes Cr, Ni, Co, V, and W, about 1.3 for Mo, and 1.7 for As, P, and Mn. Complementary tests were carried out using CRM SS-455/1 as a solid standard for one-point calibration, applying LAMTRACE software for data reduction and quantification. The analytical results are in good agreement with the certified values in all cases, showing that the applicability of dried aerosol solutions is a good alternative calibration system for laser ablation sampling.

  13. Sample Selection for Training Cascade Detectors.

    PubMed

    Vállez, Noelia; Deniz, Oscar; Bueno, Gloria

    2015-01-01

    Automatic detection systems usually require large and representative training datasets in order to obtain good detection and false positive rates. Training datasets are such that the positive set has few samples and/or the negative set should represent anything except the object of interest. In this respect, the negative set typically contains orders of magnitude more images than the positive set. However, imbalanced training databases lead to biased classifiers. In this paper, we focus our attention on a negative sample selection method to properly balance the training data for cascade detectors. The method is based on the selection of the most informative false positive samples generated in one stage to feed the next stage. The results show that the proposed cascade detector with sample selection obtains on average better partial AUC and smaller standard deviation than the other compared cascade detectors.

  14. Assessing how much couples work at their relationship: the behavioral self-regulation for effective relationships scale.

    PubMed

    Wilson, Keithia L; Charker, Jill; Lizzio, Alf; Halford, Kim; Kimlin, Siobhan

    2005-09-01

    It is widely believed that satisfying couple relationships require work by the partners. The authors equated the concept of work to relationship self-regulation and developed a scale to assess this construct. A factor analysis of the scale in a sample of 187 newlywed couples showed it comprised 2 factors of relationship strategies and effort. The factor structure was replicated in an independent sample of 97 newlywed couples. In both samples the scale had good internal consistency and high convergent validity between self- and partner-report forms. Self-regulation accounted for substantial variance in relationship satisfaction in both newlywed samples and in a 3rd sample of 61 long-married couples. The self-regulation and satisfaction association was independent of mood or self-report common method variance. (c) 2005 APA, all rights reserved

  15. Determination of aflatoxin risk components for in-shell Brazil nuts.

    PubMed

    Vargas, E A; dos Santos, E A; Whitaker, T B; Slate, A B

    2011-09-01

    A study was conducted on the risk from aflatoxins associated with the kernels and shells of Brazil nuts. Samples were collected from processing plants in Amazonia, Brazil. A total of 54 test samples (40 kg) were taken from 13 in-shell Brazil nut lots ready for market. Each in-shell sample was shelled and the kernels and shells were sorted in five fractions: good kernels, rotten kernels, good shells with kernel residue, good shells without kernel residue, and rotten shells, and analysed for aflatoxins. The kernel:shell ratio mass (w/w) was 50.2/49.8%. The Brazil nut shell was found to be contaminated with aflatoxin. Rotten nuts were found to be a high-risk fraction for aflatoxin in in-shell Brazil nut lots. Rotten nuts contributed only 4.2% of the sample mass (kg), but contributed 76.6% of the total aflatoxin mass (µg) in the in-shell test sample. The highest correlations were found between the aflatoxin concentration in in-shell Brazil nuts samples and the aflatoxin concentration in all defective fractions (R(2)=0.97). The aflatoxin mass of all defective fractions (R(2)=0.90) as well as that of the rotten nut (R(2)=0.88) were also strongly correlated with the aflatoxin concentration of the in-shell test samples. Process factors of 0.17, 0.16 and 0.24 were respectively calculated to estimate the aflatoxin concentration in the good kernels (edible) and good nuts by measuring the aflatoxin concentration in the in-shell test sample and in all kernels, respectively. © 2011 Taylor & Francis

  16. Standardization of proton-induced x-ray emission technique for analysis of thick samples

    NASA Astrophysics Data System (ADS)

    Ali, Shad; Zeb, Johar; Ahad, Abdul; Ahmad, Ishfaq; Haneef, M.; Akbar, Jehan

    2015-09-01

    This paper describes the standardization of the proton-induced x-ray emission (PIXE) technique for finding the elemental composition of thick samples. For the standardization, three different samples of standard reference materials (SRMs) were analyzed using this technique and the data were compared with the already known data of these certified SRMs. These samples were selected in order to cover the maximum range of elements in the periodic table. Each sample was irradiated for three different values of collected beam charges at three different times. A proton beam of 2.57 MeV obtained using 5UDH-II Pelletron accelerator was used for excitation of x-rays from the sample. The acquired experimental data were analyzed using the GUPIXWIN software. The results show that the SRM data and the data obtained using the PIXE technique are in good agreement.

  17. Adaptive Sampling for Urban Air Quality through Participatory Sensing

    PubMed Central

    Zeng, Yuanyuan; Xiang, Kai

    2017-01-01

    Air pollution is one of the major problems of the modern world. The popularization and powerful functions of smartphone applications enable people to participate in urban sensing to better know about the air problems surrounding them. Data sampling is one of the most important problems that affect the sensing performance. In this paper, we propose an Adaptive Sampling Scheme for Urban Air Quality (AS-air) through participatory sensing. Firstly, we propose to find the pattern rules of air quality according to the historical data contributed by participants based on Apriori algorithm. Based on it, we predict the on-line air quality and use it to accelerate the learning process to choose and adapt the sampling parameter based on Q-learning. The evaluation results show that AS-air provides an energy-efficient sampling strategy, which is adaptive toward the varied outside air environment with good sampling efficiency. PMID:29099766

  18. Older poor-sleeping women display a smaller evening increase in melatonin secretion and lower values of melatonin and core body temperature than good sleepers.

    PubMed

    Olbrich, Denise; Dittmar, Manuela

    2011-10-01

    Melatonin concentration and core body temperature (CBT) follow endogenous circadian biological rhythms. In the evening, melatonin level increases and CBT decreases. These changes are involved in the regulation of the sleep-wake cycle. Therefore, the authors hypothesized that age-related changes in these rhythms affect sleep quality in older people. In a cross-sectional study design, 11 older poor-sleeping women (aged 62-72 yrs) and 9 older good-sleeping women (60-82 yrs) were compared with 10 younger good-sleeping women (23-28 yrs). The older groups were matched by age and body mass index. Sleep quality was assessed by the Pittsburgh Sleep Quality Index questionnaire. As an indicator of CBT, oral temperature was measured at 1-h intervals from 17:00 to 24:00 h. At the same time points, saliva samples were collected for determining melatonin levels by enzyme-linked immunosorbent assay (ELISA). The dim light melatonin onset (DLMO), characterizing the onset of melatonin production, was calculated. Evening changes in melatonin and CBT levels were tested by the Friedman test. Group comparisons were performed with independent samples tests. Predictors of sleep-onset latency (SOL) were assessed by regression analysis. Results show that the mean CBT decreased in the evening from 17:00 to 24:00 h in both young women (from 36.57°C to 36.25°C, p < .001) and older women (from 36.58°C to 35.88°C, p < .001), being lowest in the older poor sleepers (p < .05). During the same time period, mean melatonin levels increased in young women (from 16.2 to 54.1 pg/mL, p < .001) and older women (from 10.0 to 23.5 pg/mL, p < .001), being lowest among the older poor sleepers (from 20:00 to 24:00 h, p < .05 vs. young women). Older poor sleepers also showed a smaller increase in melatonin level from 17:00 to 24:00 h than older good sleepers (mean ± SD: 7.0 ± 9.63 pg/mL vs. 15.6 ± 24.1 pg/mL, p = .013). Accordingly, the DLMO occurred at similar times in young (20:10 h) and older (19:57 h) good-sleeping women, but was delayed ∼50 min in older poor-sleeping women (20:47 h). Older poor sleepers showed a shorter phase angle between DLMO and sleep onset, but a longer phase angle between CBT peak and sleep onset than young good sleepers, whereas older good sleepers had intermediate phase angles (insignificant). Regression analysis showed that the DLMO was a significant predictor of SOL in the older women (R(2) = 0.64, p < .001), but not in the younger women. This indicates that melatonin production started later in those older women who needed more time to fall asleep. In conclusion, changes in melatonin level and CBT were intact in older poor sleepers in that evening melatonin increased and CBT decreased. However, poor sleepers showed a weaker evening increase in melatonin level, and their DLMO was delayed compared with good sleepers, suggesting that it is not primarily the absolute level of endogenous melatonin, but rather the timing of the circadian rhythm in evening melatonin secretion that might be related to disturbances in the sleep-wake cycle in older people.

  19. [High throuput analysis of organophosphorus pesticide residues and their metabolites in animal original foods by dual gas chromatography-dual pulse flame photometric detection].

    PubMed

    Yang, Lixin; Li, Heli; Miao, Hong; Zeng, Fangang; Li, Ruifeng; Chen, Huijing; Zhao, Yunfeng; Wu, Yongning

    2011-10-01

    A method was established for the quantitative determination of 54 organophosphorus pesticide residues and their metabolites in foods of animal origin by dual gas chromatography-dual pulse flame photometric detection. Homogenized samples were extracted with acetone and methylene chloride, and cleaned-up by gel permeation chromatography (GPC). The response of each analyte showed a good linearity with a correlation coefficient not less than 0. 99. The recovery experiments were performed by a blank sample spiked at low, medium and high fortification levels. The recoveries for beef, mutton, pork, chicken were in the range of 50. 5% -128. 1% with the relative standard deviations (n = 6) of 1. 1% -25. 5%, which demonstrated the good precision and accuracy of the present method. The limits of detection for the analytes were in the range of 0. 001 -0. 170 mg/kg, and the limits of quantification were in the range of 0. 002 -0. 455 mg/kg. Animal food samples collected from markets such as meat, liver and kidney were analyzed, and the residues of dichlorovos and disulfoton-sulfoxide were found in the some samples. The established method is sensitive and selective enough to detect organophosphorus pesticide residues in animal foods.

  20. Rapid determination of caffeine in one drop of beverages and foods using drop-to-drop solvent microextraction with gas chromatography/mass spectrometry.

    PubMed

    Shrivas, Kamlesh; Wu, Hui-Fen

    2007-11-02

    A simple and rapid sample cleanup and preconcentration method for the quantitative determination of caffeine in one drop of beverages and foods by gas chromatography/mass spectrometry (GC/MS) has been proposed using drop-to-drop solvent microextraction (DDSME). The best optimum experimental conditions for DDSME were: chloroform as the extraction solvent, 5 min extraction time, 0.5 microL exposure volume of the extraction phase and no salt addition at room temperature. The optimized methodology exhibited good linearity between 0.05 and 5.0 microg/mL with correlation coefficient of 0.980. The relative standard deviation (RSD) and limits of detection (LOD) of the DDSME/GC/MS method were 4.4% and 4.0 ng/mL, respectively. Relative recovery of caffeine in beverages and foods were found to be 96.6-101%, which showing good reliability of this method. This DDSME excludes the major disadvantages of conventional method of caffeine extraction, like large amount of organic solvent and sample consumption and long sample pre-treatment process. So, this approach proves that the DDSME/GC/MS technique can be applied as a simple, fast and feasible diagnosis tool for environmental, food and biological application for extremely small amount of real sample analysis.

  1. Microbiological quality and safe handling of enteral diets in a hospital in Minas Gerais, Brazil

    PubMed Central

    Pinto, Raquel Oliveira Medrado; Correia, Eliznara Fernades; Pereira, Keyla Carvalho; Costa, Paulo de Souza; da Silva, Daniele Ferreira

    2015-01-01

    Contamination of enteral diets represents a high risk of compromising the patient's medical condition. To assess the microbiological quality and aseptic conditions in the preparation and administration of handmade and industrialized enteral diets offered in a hospital in the Valley of Jequitinhonha, MG, Brazil, we performed a microbiological analysis of 50 samples of diets and 27 samples of surfaces, utensils, and water used in the preparation of the diets. In addition, we assessed the good handling practices of enteral diets according to the requirements specified by the Brazilian legislation. Both kinds of enteral diets showed contamination by coliforms and Pseudomonas spp. No sample was positive for Staphylococcus aureus and Salmonella spp. On the other hand, Listeria spp. was detected in only one sample of handmade diets. Contamination was significantly higher in the handmade preparations (p < 0.05). Nonconformities were detected with respect to good handling practices, which may compromise the diet safety. The results indicate that the sanitary quality of the enteral diets is unsatisfactory, especially handmade diets. Contamination by Pseudomonas spp. is significant because it is often involved in infection episodes. With regard to aseptic practices, it was observed the need of implementing new procedures for handling enteral diets. PMID:26273278

  2. Probiotic Properties of Lactobacillus fermentum Strains Isolated from Human Oral Samples and Description of their Antibacterial Activity.

    PubMed

    Fuochi, Virginia; Volti, Giovanni Li; Furneri, Pio M

    2017-01-01

    Gram positive bacteria produce peptides, defined bacteriocins which exhibit good antibacterial activity. We evaluated the ability of L. fermentum to produce bacteriocins having therefore, good probiotic features and finally, be safe towards microglial cells. Eight wild strains, identified using molecular techniques, were investigated for the evaluation of resistance to bile salts, low pH, H2O2 production, biofilm formation, antibacterial activity and safety on microglia cells (BV2). The determination of the susceptibility/resistance profile showed that the strains are sensitive to the antibiotics tested. All strains showed a good tolerability to extremely low pH as well as resisting in presence of bile salts. In addition, the strains showed excellent activity against pathogens and one of them (LAC 42) showed activity also against Pseudomonas aeruginosa and Klebsiella pneumoniae. Finally, LAC 42 and its active compound did not change microglia cell viability following 24h exposure. Our data on this antibacterial molecule suggest that it is a compound with low molecular weight and with highly hydrophilic component. These results describe the characteristics of Lactobacillus strains and provide evidences for their possible use as new potential probiotic. In addition, other studies are now warranted to exploit the antibacterial activity of the supernatant LAC 42 and for its complete chemical characterization. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  3. Evaluation of the Microsemi CRP, an automated hematology analyzer for rapid 3-part WBC differential and CRP using whole blood.

    PubMed

    Nomura, N; Saito, K; Ikeda, M; Yuasa, S; Pastore, M; Chabert, C; Kono, E; Sakai, A; Tanaka, H; Ikemoto, T; Takubo, T

    2015-08-01

    We evaluated the basic performance of Microsemi CRP, an unique automated hematology analyzer which can simultaneously measure CBC including 3-part WBC differential (3-Diff) and CRP using whole blood treated with EDTA-2K anticoagulant. We found that it produced generally the acceptable results for all parameters performed (repeatability, reproducibility, linearity, interference effect, carry over, and correlation) using control materials, fresh human whole bloods, and serum samples. CBC data examined using Microsemi CRP showed the good correlation with the previous model, Micros CRP200 (r ≧ 0.9), and also those obtained using the routine analyzer, ADVIA 2120i (r ≧ 0.989). Concerning the 3-Diff, both GRA (%) and LYM (%) showed the excellent correlation coefficient between Microsemi CRP and Micros CRP200 (r ≧ 0.992) as well as ADVIA 2120i (r ≧ 0.957). MON (%) showed good correlation between Microsemi CRP and Micros CRP200 (r = 0.959), but lower correlation between Microsemi CRP and ADVIA 2120 i (r = 0.471). CRP data showed the good correlation with HITACHI7600 (r ≧ 0.997) and Micros CRP200 (r ≧ 0.997). From these findings, we concluded that Microsemi CRP seemed the convenient laboratory analyzer in the setting of point of care testing (POCT) especially at NICU or primary care unit. © 2014 John Wiley & Sons Ltd.

  4. Comparative study of the synbiotic effect of inulin and fructooligosaccharide with probiotics with regard to the various properties of fermented soy milk.

    PubMed

    Mishra, Shalini; Mishra, H N

    2018-01-01

    Numerous combinations of probiotics were explored to find the suitable starter culture for the development of synbiotic soy yoghurt which can give good product characteristics and may be acceptable among consumers. Prebiotics (fructooligosaccharide (FOS) and inulin) were supplemented in an attempt to reduce the after-taste of soymilk, improve acidification profile and growth of probiotics. The addition of prebiotics in soy milk significantly enhanced the acidification rate (10.82 to 23.00 × 10 -3 pH units/min) and condensed the fermentation completion time. FOS-supplemented fermented soy milk showed better acidification and post-acidification profile as compared to inulin supplemented samples. The Streptococcus salivarius subsp. thermophilus (ST) - Lactobacillus acidophilus (LA) with FOS gave the better textural properties with firmer gel (350.10), lower adhesiveness (-93.10) and springiness (0.92), higher gumminess (164.50) and average cohesiveness (0.47). FOS-supplemented ST-LA-fermented samples showed good gel characteristics with higher elastic modulus (1672.39 Pa), viscous modulus (416.41 Pa), complex modulus (1723.53 Pa), lower tan δ (14) and higher overall acceptability scores (7.40) on a 9-point hedonic scale. Developed synbiotic soy fermented milk showed more than the 9 log cfu/ml count throughout storage which is required for probiotic functional food.

  5. Application of portable X-ray fluorescence spectrometry in environmental investigation of heavy metal-contaminated sites and comparison with laboratory analysis

    NASA Astrophysics Data System (ADS)

    Ding, Liang; Wang, Shui; Cai, Bingjie; Zhang, Mancheng; Qu, Changsheng

    2018-02-01

    In this study, portable X-ray fluorescence spectrometry (pXRF) was used to measure the heavy metal contents of As, Cu, Cr, Ni, Pb and Zn in the soils of heavy metal-contaminated sites. The precision, accuracy and system errors of pXRF were evaluated and compared with traditional laboratory methods to examine the suitability of in situ pXRF. The results show that the pXRF analysis achieved satisfactory accuracy and precision in measuring As, Cr, Cu, Ni, Pb, and Zn in soils, and meets the requirements of the relevant detection technology specifications. For the certified reference soil samples, the pXRF results of As, Cr, Cu, Ni, Pb, and Zn show good linear relationships and coefficients of determination with the values measured using the reference analysis methods; with the exception of Ni, all the measured values were within the 95% confidence level. In the soil samples, the coefficients of determination between Cu, Zn, Pb, and Ni concentrations measured laboratory pXRF and the values measured with laboratory analysis all reach 0.9, showing a good linear relationship; however, there were large deviations between methods for Cr and As. This study provides reference data and scientific support for rapid detection of heavy metals in soils using pXRF in site investigation, which can better guide the practical application of pXRF.

  6. Rapid and Cost-Effective Quantification of Glucosinolates and Total Phenolic Content in Rocket Leaves by Visible/Near-Infrared Spectroscopy.

    PubMed

    Toledo-Martín, Eva María; Font, Rafael; Obregón-Cano, Sara; De Haro-Bailón, Antonio; Villatoro-Pulido, Myriam; Del Río-Celestino, Mercedes

    2017-05-20

    The potential of visible-near infrared spectroscopy to predict glucosinolates and total phenolic content in rocket ( Eruca vesicaria ) leaves has been evaluated. Accessions of the E. vesicaria species were scanned by NIRS as ground leaf, and their reference values regressed against different spectral transformations by modified partial least squares (MPLS) regression. The coefficients of determination in the external validation (R²VAL) for the different quality components analyzed in rocket ranged from 0.59 to 0.84, which characterize those equations as having from good to excellent quantitative information. These results show that the total glucosinolates, glucosativin and glucoerucin equations obtained, can be used to identify those samples with low and high contents. The glucoraphanin equation obtained can be used for rough predictions of samples and in case of total phenolic content, the equation showed good correlation. The standard deviation (SD) to standard error of prediction ratio (RPD) and SD to range (RER) were variable for the different quality compounds and showed values that were characteristic of equations suitable for screening purposes or to perform accurate analyses. From the study of the MPLS loadings of the first three terms of the different equations, it can be concluded that some major cell components such as protein and cellulose, highly participated in modelling the equations for glucosinolates.

  7. [Optimization of a cake formulation with functional characteristics using resistant starch, Sphagnum magellanicum moss and deffated hazel nut flour (Gevuina avellana, Mol)].

    PubMed

    Villarroel, Mario; Reyes, Carla; Hazbun, Julia; Karmelic, Julia

    2007-03-01

    Resistant starch (RS) Hi Maize 260, Sphagnum magellanicum Moss (SM) both natural resources rich in total dietary fiber, and defatted hazel nut flour (DHN) as protein resource were used in the development of a pastry product (queque) with functional characteristics. Taguchi methodology was utilized in the optimization process using the orthogonal array L934 with four control factors: RS, SM. DHN and Master Gluten 4000 (MG), 3 factor levels and 9 experimental trials. The best result of Sensory Quality (SQ) and signal to noise ratio (S/N) was obtained combining the minor levels of the independent variables. Main effect (average effects of factor) analysis and anova analysis showed that SM and DHN were the control factors with a significant influence (p<0.05) on the CS with a relative contribution of 83%. It is important to emphasize the total dietary fiber (8.7%) and protein (7.2%) values, the formers due to the presence of RS and SM. Shelf life study showed that the sensory characteristics flavour, appearance and texture were not affected when samples were stored at refrigerated temperatures but not at 20 degrees C, specifically flavour always kept a good preference during the whole period of time. Samples of optimized cakes showed very good results when they were submitted to hedonic test with 100% of favorable consumer's opinions.

  8. Development and validation of brief scales to measure emotional and behavioural problems among Chinese adolescents

    PubMed Central

    Shen, Minxue; Hu, Ming; Sun, Zhenqiu

    2017-01-01

    Objectives To develop and validate brief scales to measure common emotional and behavioural problems among adolescents in the examination-oriented education system and collectivistic culture of China. Setting Middle schools in Hunan province. Participants 5442 middle school students aged 11–19 years were sampled. 4727 valid questionnaires were collected and used for validation of the scales. The final sample included 2408 boys and 2319 girls. Primary and secondary outcome measures The tools were assessed by the item response theory, classical test theory (reliability and construct validity) and differential item functioning. Results Four scales to measure anxiety, depression, study problem and sociality problem were established. Exploratory factor analysis showed that each scale had two solutions. Confirmatory factor analysis showed acceptable to good model fit for each scale. Internal consistency and test–retest reliability of all scales were above 0.7. Item response theory showed that all items had acceptable discrimination parameters and most items had appropriate difficulty parameters. 10 items demonstrated differential item functioning with respect to gender. Conclusions Four brief scales were developed and validated among adolescents in middle schools of China. The scales have good psychometric properties with minor differential item functioning. They can be used in middle school settings, and will help school officials to assess the students’ emotional/behavioural problems. PMID:28062469

  9. Psychometric properties of the Portuguese version of the Acceptance and Action Questionnaire-Trauma Specific (AAQ-TS): A study with Portuguese Colonial War Veterans.

    PubMed

    Pinto-Gouveia, José; Carvalho, Teresa; Cunha, Marina; Duarte, Joana; Walser, Robyn D

    2015-10-01

    The Acceptance and Action Questionnaire-Trauma Specific (AAQ-TS) is a self-report measure designed to assess-trauma-related psychological (in)flexibility, as conceptualized in Acceptance and Commitment Therapy. However, there are no studies to date regarding its psychometric properties. This study explores such properties in the Portuguese version of the AAQ-TS, in Portuguese Colonial War Veterans. A Principal Components Analysis (PCA) was conducted in a sample from the general population of war Veterans (N=371). Confirmatory Factor Analysis (CFA) as well as reliability and convergent validity studies were performed in a different sample from the same population (N=312). For the discriminant validity a clinical sample with a war-related PTSD (N=42) and a non-clinical sample without PTSD (N=44) were used. The CFA suggested a re-specified 15-item model with good global adjustment and factorial validity. The AAQ-TS showed internal consistency, a good temporal reliability, convergent validity with psychopathological symptoms (related to PTSD, anxiety, depression and stress) and peritraumatic dissociation (altered awareness and depersonalization/derealization). The questionnaire also discriminates between war Veterans with and without a PTSD diagnosis. The major limitation relates to the samples' characteristics and sampling methods, which can limit the generalization of results. The Portuguese version of the AAQ-TS is a reliable and valid measure to assess experiential avoidance related to trauma in Portuguese Colonial War Veterans. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. [Adaptation of the Hinting Task theory of the mind test to Spanish].

    PubMed

    Gil, David; Fernández-Modamio, Mar; Bengochea, Rosario; Arrieta, Marta

    2012-01-01

    Many studies have found that patients with schizophrenia have a deficit in theory of mind. Some authors associate this deficit with the presence of symptoms, while others maintain that it can also be observed in patients in the remission phase. There is no reference test to assess theory of mind in schizophrenia, although one of the most used is the Hinting Task. The aim of the present study consists of adapting and validating, in Spanish, the 10 histories that make up this test. The study was conducted on a sample of 39 control subjects and 40 patients with schizophrenia. The internal consistency and the between-observer reliability and test-retest were assessed in both sample groups. The performance of the patients and control subjects were also compared. Good reliability data was obtained in the inter-observer and test-retest in the two samples. On the other hand, the internal consistency was somewhat low for all of the 10 histories. For this reason, and starting from a previous study, a reduced version of 5 histories was prepared, which showed good internal consistency. The patients with schizophrenia obtained a significantly lower score than the control subjects in 8 out of the 10 histories. The reduced Spanish version of the Hinting Task demonstrated good psychometric properties. When compared to the control group, the patients with schizophrenia had a deficit in theory of mind. Copyright © 2011 SEP y SEPB. Published by Elsevier Espana. All rights reserved.

  11. Extractive procedure for uranium determination in water samples by liquid scintillation counting.

    PubMed

    Gomez Escobar, V; Vera Tomé, F; Lozano, J C; Martín Sánchez, A

    1998-07-01

    An extractive procedure for uranium determination using liquid scintillation counting with the URAEX cocktail is described. Interference from radon and a strong influence of nitrate ion were detected in this procedure. Interference from radium, thorium and polonium emissions were very low when optimal operating conditions were reached. Quenching effects were considered and the minimum detectable activity was evaluated for different sample volumes. Isotopic analysis of samples can be performed using the proposed method. Comparisons with the results obtained with the general procedure used in alpha spectrometry with passivated implanted planar silicon detectors showed good agreement. The proposed procedure is thus suitable for uranium determination in water samples and can be considered as an alternative to the laborious conventional chemical preparations needed for alpha spectrometry methods using semiconductor detectors.

  12. Rapidly Mixing Gibbs Sampling for a Class of Factor Graphs Using Hierarchy Width.

    PubMed

    De Sa, Christopher; Zhang, Ce; Olukotun, Kunle; Ré, Christopher

    2015-12-01

    Gibbs sampling on factor graphs is a widely used inference technique, which often produces good empirical results. Theoretical guarantees for its performance are weak: even for tree structured graphs, the mixing time of Gibbs may be exponential in the number of variables. To help understand the behavior of Gibbs sampling, we introduce a new (hyper)graph property, called hierarchy width . We show that under suitable conditions on the weights, bounded hierarchy width ensures polynomial mixing time. Our study of hierarchy width is in part motivated by a class of factor graph templates, hierarchical templates , which have bounded hierarchy width-regardless of the data used to instantiate them. We demonstrate a rich application from natural language processing in which Gibbs sampling provably mixes rapidly and achieves accuracy that exceeds human volunteers.

  13. Properties of young massive clusters obtained with different massive-star evolutionary models

    NASA Astrophysics Data System (ADS)

    Wofford, Aida; Charlot, Stéphane

    We undertake a comprehensive comparative test of seven widely-used spectral synthesis models using multi-band HST photometry of a sample of eight YMCs in two galaxies. We provide a first quantitative estimate of the accuracies and uncertainties of new models, show the good progress of models in fitting high-quality observations, and highlight the need of further comprehensive comparative tests.

  14. Personality Inventory for DSM-5-Short Form (PID-5-SF): Reliability, Factorial Structure, and Relationship With Functional Impairment in Dual Diagnosis Patients.

    PubMed

    Díaz-Batanero, Carmen; Ramírez-López, Juan; Domínguez-Salas, Sara; Fernández-Calderón, Fermín; Lozano, Óscar M

    2017-11-01

    Section III of the Diagnostic and Statistical Manual of Mental Disorders-Fifth edition ( DSM-5) has generated a personality paradigm consisting of 25 personality facets identified in five domains. The developed assessment instrument Personality Inventory for DSM-5 (PID-5) has showed good psychometric properties, but the potential for certain improvements still remain. In this article, a sample of 282 dual diagnosis patients is used to provide evidence of the psychometric properties of the PID-5-Short Form. The mean value of Cronbach's alpha coefficients reached .73 on the facets and .84 for domains and test-retest values ranged between .57 to .83 for facets and .70 to .87 for the domains. Confirmatory factor analyses conducted showed good fit on both models tested: the five correlated factor structure and hierarchical structure of personality traits. The WHODAS 2.0 domains of understanding and communicating, and participating in society, appear to show the strongest relationship with personality facets. In general, the PID-5-Short Form shows adequate psychometric properties for use in dual diagnosis patients.

  15. Measurement of tritium with high efficiency by using liquid scintillation counter with plastic scintillator.

    PubMed

    Furuta, Etsuko; Ohyama, Ryu-ichiro; Yokota, Shigeaki; Nakajo, Toshiya; Yamada, Yuka; Kawano, Takao; Uda, Tatsuhiko; Watanabe, Yasuo

    2014-11-01

    The detection efficiencies of tritium samples by using liquid scintillation counter with hydrophilic plastic scintillator (PS) was approximately 48% when the sample of 20 μL was held between 2 PS sheets treated by plasma. The activity and count rates showed a good relationship between 400 Bq to 410 KBq mL(-1). The calculated detection limit of 2 min measurement by the PS was 13 Bq mL(-1) when a confidence was 95%. The plasma method for PS produces no radioactive waste. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Inter-comparison of boron concentration measurements at INFN-University of Pavia (Italy) and CNEA (Argentina).

    PubMed

    Portu, Agustina; Postuma, Ian; Gadan, Mario Alberto; Saint Martin, Gisela; Olivera, María Silvina; Altieri, Saverio; Protti, Nicoletta; Bortolussi, Silva

    2015-11-01

    An inter-comparison of three boron determination techniques was carried out between laboratories from INFN-University of Pavia (Italy) and CNEA (Argentina): alpha spectrometry (alpha-spect), neutron capture radiography (NCR) and quantitative autoradiography (QTA). Samples of different nature were analysed: liquid standards, liver homogenates and tissue samples from different treatment protocols. The techniques showed a good agreement in a concentration range of interest in BNCT (1-100ppm), thus demonstrating their applicability as precise methods to quantify boron and determine its distribution in tissues. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. An experimental SMI adaptive antenna array simulator for weak interfering signals

    NASA Technical Reports Server (NTRS)

    Dilsavor, Ronald S.; Gupta, Inder J.

    1991-01-01

    An experimental sample matrix inversion (SMI) adaptive antenna array for suppressing weak interfering signals is described. The experimental adaptive array uses a modified SMI algorithm to increase the interference suppression. In the modified SMI algorithm, the sample covariance matrix is redefined to reduce the effect of thermal noise on the weights of an adaptive array. This is accomplished by subtracting a fraction of the smallest eigenvalue of the original covariance matrix from its diagonal entries. The test results obtained using the experimental system are compared with theoretical results. The two show a good agreement.

  18. 65Zn and 133Ba standardizing by photon-photon coincidence counting

    NASA Astrophysics Data System (ADS)

    Loureiro, Jamir S.; da Cruz, Paulo A. L.; Iwahara, Akira; Delgado, José U.; Lopes, Ricardo T.

    2018-03-01

    The LNMRI/Brazil has deployed a system using X-gamma coincidence technique for the standardizing radionuclide, which present simple and complex decay scheme with X-rays of energy below 100 keV. The work was carried on radionuclide metrology laboratory using a sodium iodide detector, for gamma photons, in combination with a high purity germanium detector for X-rays. Samples of 65Zn and 133Ba were standardized and the results for both radionuclides showed good precision and accuracy when compared with reference values. The standardization differences were 0.72 % for 65Zn and 0.48 % for 133Ba samples.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, R.F.; Kravchenko, I.I.; Kuharik, J.C.

    Widespread use of chromated copper arsenate (CCA) as a wood preservative has led to increasing public concern regarding possible toxic contamination of areas surrounding CCA-treated structures, e.g., decks, playground equipment, etc. Appreciable leaching of arsenic, chromium, and copper into soils adjacent to such structures has been demonstrated via standard techniques of analytical chemistry. The advantages of PIXE [rapid analysis, quick sample turnover, possible lower cost] suggest its application to this area of interest. PIXE studies in our laboratory of CCA-contaminated soil samples show good agreement with previous analyses of As, Cu, Cr, and other heavy-elemental content, with some variability inmore » diffusion rates.« less

  20. A novel method to estimate the affinity of HLA-A∗0201 restricted CTL epitope

    NASA Astrophysics Data System (ADS)

    Xu, Yun-sheng; Lin, Yong; Zhu, Bo; Lin, Zhi-hua

    2009-02-01

    A set of 70 peptides with affinity for the class I MHC HLA-A∗0201 molecule was subjected to quantitative structure-affinity relationship studies based on the SCORE function with good results ( r2 = 0.6982, RMS = 0.280). Then the 'leave-one-out' cross-validation (LOO-CV) and an outer test set including 18 outer samples were used to validate the QSAR model. The results of the LOO-CV were q2 = 0.6188, RMS = 0.315, and the results of outer test set were r2 = 0.5633, RMS = 0.2292. All these show that the QSAR model has good predictability. Statistical analysis showed that the hydrophobic and hydrogen bond interaction played a significant role in peptide-MHC molecule binding. The study also provided useful information for structure modification of CTL epitope, and laid theoretical base for molecular design of therapeutic vaccine.

  1. Development of the CarMen-Q Questionnaire for mental workload assessment.

    PubMed

    Rubio-Valdehita, Susana; López-Núñez, María I; López-Higes, Ramón; Díaz-Ramiro, Eva M

    2017-11-01

    Mental workload has emerged as one of the most important occupational risk factors present in most psychological and physical diseases caused by work. In view of the lack of specific tools to assess mental workload, the objective of this research was to assess the construct validity and reliability of a new questionnaire for mental workload assessment (CarMen-Q). The sample was composed of 884 workers from several professional sectors, between 18 and 65 years old, 53.4% men and 46.6% women. To evaluate the validity based on relationships with other measures, the NASA-TLX scale was also administered. Confirmatory factor analysis showed an internal structure made up of four dimensions: cognitive, temporal and emotional demands and performance requirement. The results show satisfactory evidence of validity based on relationships with NASA-TLX and good reliability. The questionnaire has good psychometric properties and can be an easy, brief, useful tool for mental workload diagnosis and prevention.

  2. A new questionnaire for measuring quality of life - the Stark QoL.

    PubMed

    Hardt, Jochen

    2015-10-26

    The Stark questionnaire measures health-related quality of life (QoL) using pictures almost exclusively. It is supplemented by a minimum of words. It comprises a mental and a physical health component. A German sample of n = 500 subjects, age and gender stratified, filled out the Stark Qol questionnaire along with various other questionnaires via internet. The physical component shows good reliability (Cronbach's alpha = McDonalds Omega = greatest lower bound = .93), the mental component can be improved (Cronbach's alpha = .63, McDonalds Omega = .72, greatest lower bound = .77). Confirmatory factor analysis shows a good fit (Bentlers CFI = .97). Construct validity was proven. The Stark QoL is a promising new development in measuring QoL, it is a short and easy to apply questionnaire. Additionally, it is particularly promising for international research.

  3. Testing the Zimbardo Time Perspective Inventory in the Chinese context.

    PubMed

    Wang, Ya; Chen, Xing-Jie; Cui, Ji-Fang; Liu, Lu-Lu

    2015-09-01

    In this study, the authors evaluated the Chinese version of the Zimbardo Time Perspective Inventory (ZTPI). The ZTPI was tested among a sample of 303 university students. A subsample of 51 participants was then asked to complete the ZTPI again along with another set of questionnaires. The five-factor model of a 20-item short version of the ZTPI showed good model fit, internal consistency, and test-retest reliability. The 20-item Chinese version of the ZTPI also provided good validity, showing correlations with other variables in expected directions. Past-Positive was positively correlated with reappraisal and negatively correlated with suppression emotion regulation strategies, and Present-Hedonistic was positively correlated with reappraisal emotion regulation strategies. These findings indicate that the ZTPI is a reliable and valid instrument for measuring time perspective in the Chinese setting. © 2015 The Institute of Psychology, Chinese Academy of Sciences and Wiley Publishing Asia Pty Ltd.

  4. An Analysis of the Connectedness to Nature Scale Based on Item Response Theory.

    PubMed

    Pasca, Laura; Aragonés, Juan I; Coello, María T

    2017-01-01

    The Connectedness to Nature Scale (CNS) is used as a measure of the subjective cognitive connection between individuals and nature. However, to date, it has not been analyzed at the item level to confirm its quality. In the present study, we conduct such an analysis based on Item Response Theory. We employed data from previous studies using the Spanish-language version of the CNS, analyzing a sample of 1008 participants. The results show that seven items presented appropriate indices of discrimination and difficulty, in addition to a good fit. The remaining six have inadequate discrimination indices and do not present a good fit. A second study with 321 participants shows that the seven-item scale has adequate levels of reliability and validity. Therefore, it would be appropriate to use a reduced version of the scale after eliminating the items that display inappropriate behavior, since they may interfere with research results on connectedness to nature.

  5. Polyhydroquinone-graphene composite as new redox species for sensitive electrochemical detection of cytokeratins antigen 21-1

    NASA Astrophysics Data System (ADS)

    Wang, Huiqiang; Rong, Qinfeng; Ma, Zhanfang

    2016-07-01

    Polyhydroquinone-graphene composite as a new redox species was synthesized simply by a microwave-assisted one-pot method through oxidative polymerization of hydroquinone by graphene oxide, which exhibited excellent electrochemical redox activity at 0.124 V and can remarkably promote electron transfer. The as-prepared composite was used as immunosensing substrate in a label-free electrochemical immunosensor for the detection of cytokeratins antigen 21-1, a kind of biomarker of lung cancer. The proposed immunosensor showed wide liner range from 10 pg mL-1 to 200 ng mL-1 with a detection limit 2.3 pg mL-1, and displayed a good stability and selectivity. In addition, this method has been used for the analysis of human serum sample, and the detection results showed good consistence with those of ELISA. The present substrate can be easily extended to other polymer-based nanocomposites.

  6. High performance UV and thermal cure hybrid epoxy adhesive

    NASA Astrophysics Data System (ADS)

    Chen, C. F.; Iwasaki, S.; Kanari, M.; Li, B.; Wang, C.; Lu, D. Q.

    2017-06-01

    New type one component UV and thermal curable hybrid epoxy adhesive was successfully developed. The hybrid epoxy adhesive is complete initiator free composition. Neither photo-initiator nor thermal initiator is contained. The hybrid adhesive is mainly composed of special designed liquid bismaleimide, partially acrylated epoxy resin, acrylic monomer, epoxy resin and latent curing agent. Its UV light and thermal cure behavior was studied by FT-IR spectroscopy and FT-Raman spectroscopy. Adhesive samples cured at UV only, thermal only and UV + thermal cure conditions were investigated. By calculated conversion rate of double bond in both acrylic component and maleimide compound, satisfactory light curability of the hybrid epoxy adhesive was confirmed quantitatively. The investigation results also showed that its UV cure components, acrylic and bismalimide, possess good thermal curability too. The initiator free hybrid epoxy adhesive showed satisfactory UV curability, good thermal curability and high adhesion performance.

  7. Analysis of titanium content in titanium tetrachloride solution

    NASA Astrophysics Data System (ADS)

    Bi, Xiaoguo; Dong, Yingnan; Li, Shanshan; Guan, Duojiao; Wang, Jianyu; Tang, Meiling

    2018-03-01

    Strontium titanate, barium titan and lead titanate are new type of functional ceramic materials with good prospect, and titanium tetrachloride is a commonly in the production such products. Which excellent electrochemical performance of ferroelectric tempreature coefficient effect.In this article, three methods are used to calibrate the samples of titanium tetrachloride solution by back titration method, replacement titration method and gravimetric analysis method. The results show that the back titration method has many good points, for example, relatively simple operation, easy to judgment the titration end point, better accuracy and precision of analytical results, the relative standard deviation not less than 0.2%. So, it is the ideal of conventional analysis methods in the mass production.

  8. Fast, Dense Low Cost Scintillator for Nuclear Physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woody, Craig

    2009-07-31

    We have studied the morphology, transparency, and optical properties of SrHfO{sub 3}:Ce ceramics. Ceramics can be made transparent by carefully controlling the stoichiometry of the precursor powders. When fully dense, transparent samples can be obtained. Ceramics with a composition close to stoichiometry (Sr:Hf ~ 1) appear to show good transparency and a reasonable light yield several times that of BGO. The contact and distance transparency of ceramics hot-pressed at about 1450ºC is very good, but deteriorates at increasingly higher hot-press temperatures. If these ceramics can be produced in large quantities and sizes, at low cost, they may be of considerablemore » interest for PET and CT.« less

  9. Thermoelectric properties and thermal stability of Bi-doped PbTe single crystal

    NASA Astrophysics Data System (ADS)

    Chen, Zhong; Li, Decong; Deng, Shuping; Tang, Yu; Sun, Luqi; Liu, Wenting; Shen, Lanxian; Yang, Peizhi; Deng, Shukang

    2018-06-01

    In this study, n-type Bi-doped single-crystal PbTe thermoelectric materials were prepared by melting and slow cooling method according to the stoichiometric ratio of Pb:Bi:Te = 1-x:x:1 (x = 0, 0.1, 0.15, 0.2, 0.25). The X-ray diffraction patterns of Pb1-xBixTe samples show that all main diffraction peaks are well matched with the PbTe matrix, which has a face-centered cubic structure with the space group Fm 3 bar m . Electron probe microanalysis reveals that Pb content decreases gradually, and Te content remains invariant basically with the increase of Bi content, indicating that Bi atoms are more likely to replace Pb atoms. Thermal analysis shows that the prepared samples possess relatively high thermal stability. Simultaneously, transmission electron microscopy and selected area electron diffraction pattern indicate that the prepared samples have typical single-crystal structures with good mechanical properties. Moreover, the electrical conductivity of the prepared samples improved significantly compared with that of the pure sample, and the maximum ZT value of 0.84 was obtained at 600 K by the sample with x = 0.2.

  10. Design and validation of a wind tunnel system for odour sampling on liquid area sources.

    PubMed

    Capelli, L; Sironi, S; Del Rosso, R; Céntola, P

    2009-01-01

    The aim of this study is to describe the methods adopted for the design and the experimental validation of a wind tunnel, a sampling system suitable for the collection of gaseous samples on passive area sources, which allows to simulate wind action on the surface to be monitored. The first step of the work was the study of the air velocity profiles. The second step of the work consisted in the validation of the sampling system. For this purpose, the odour concentration of some air samples collected by means of the wind tunnel was measured by dynamic olfactometry. The results of the air velocity measurements show that the wind tunnel design features enabled the achievement of a uniform and homogeneous air flow through the hood. Moreover, the laboratory tests showed a very good correspondence between the odour concentration values measured at the wind tunnel outlet and the odour concentration values predicted by the application of a specific volatilization model, based on the Prandtl boundary layer theory. The agreement between experimental and theoretical trends demonstrate that the studied wind tunnel represents a suitable sampling system for the simulation of specific odour emission rates from liquid area sources without outward flow.

  11. Comparison of mine waste assessment methods at the Rattler mine site, Virginia Canyon, Colorado

    USGS Publications Warehouse

    Hageman, Phil L.; Smith, Kathleen S.; Wildeman, Thomas R.; Ranville, James F.

    2005-01-01

    In a joint project, the mine waste-piles at the Rattler Mine near Idaho Springs, Colorado, were sampled and analyzed by scientists from the U.S. Geological Survey (USGS) and the Colorado School of Mines (CSM). Separate sample collection, sample leaching, and leachate analyses were performed by both groups and the results were compared. For the study, both groups used the USGS sampling procedure and the USGS Field Leach Test (FLT). The leachates generated from these tests were analyzed for a suite of elements using ICP-AES (CSM) and ICP-MS (USGS). Leachate geochemical fingerprints produced by the two groups for composites collected from the same mine waste showed good agreement. In another set of tests, CSM collected another set of Rattler mine waste composite samples using the USGS sampling procedure. This set of composite samples was leached using the Colorado Division of Minerals and Geology (CDMG) leach test, and a modified Toxicity Characteristic Leaching Procedure (TCLP) leach test. Leachate geochemical fingerprints produced using these tests showed a variation of more than a factor of two from the geochemical fingerprints produced using the USGS FLT leach test. We have concluded that the variation in the results is due to the different parameters of the leaching tests and not due to the sampling or analytical methods.

  12. The Resazurin-Agar Method - a Quick Test to Determine Water Quality

    NASA Astrophysics Data System (ADS)

    Huckfeldt, J.; Westphal, B.; Claußen, L.

    2015-12-01

    Rezasurin has been used as a smart tracer in stream ecosystems to indicate metabolic activity, specifically aerobic respiration by heterotrophic bacteria. Resazurin is a blue compound which is irreversibly reduced to the pink resorufin in the presence of aerobic bacteria. The degree and speed of colour change from blue to pink is a measure of the degree of oxygen consumption and thus an indirect indication of the concentration of aerobic bacteria in a given medium. A high concentration of bacteria in water indicates a bad water quality. In our work a method was developed using resazurin agar plates to find a quick and easy way for testing water quality and comparing concentrations of bacteria in freshwater and seawater samples. The theory was to concentrate bacteria from a defined volume of water sample onto polycarbonate filters (0.2 μm), which are then placed onto the resazurin agar plate. The presence of aerobic bacteria on the filter will reduce the resazurin in the agar and the compound changes its colour. First tests conducted with different dilutions of a pure culture of yoghurt bacteria showed promising results and confirmed the feasibility of the method. In a further assay, we used water samples from different water layers and different temperatures and were also able to observe differences in the concentration of bacteria, depending on these different environmental conditions.The assay was also successfully used with seawater samples, collected from 2 different stations at 3 different depths in the Baltic Sea (salinity=15). The discolouration of the plates showed good correlation with the oxygen concentrations in the water. The resazurin-agar plate method is economical and fast. Several samples could be investigated at the same time without sacrificing the reliability of the results. Thus it is a good pre-screening test for a quantitative evaluation of bacteria in a water sample.

  13. Good self-control as a buffering agent for adolescent substance use: an investigation in early adolescence with time-varying covariates.

    PubMed

    Wills, Thomas A; Ainette, Michael G; Stoolmiller, Mike; Gibbons, Frederick X; Shinar, Ori

    2008-12-01

    This study tested the prediction that self-control would have buffering effects for adolescent substance use (tobacco, alcohol, and marijuana) with regard to 3 risk factors: family life events, adolescent life events, and peer substance use. Participants were a sample of public school students (N = 1,767) who were surveyed at 4 yearly intervals between 6th grade and 9th grade. Good self-control was assessed with multiple indicators (e.g., planning and problem solving). Results showed that the impact of all 3 risk factors on substance use was reduced among persons with higher scores on good self-control. Buffering was found in cross-sectional analyses with multiple regression and in longitudinal analyses in a latent growth model with time-varying covariates. Implications for addressing self-control in prevention programs are discussed. 2008 APA, all rights reserved

  14. Evaluation of a recombinant LigB protein of Leptospira interrogans serovar Canicola in an enzyme-linked immunosorbent assay for the serodiagnosis of bovine leptospirosis.

    PubMed

    Sankar, Surya; Harshan, Hiron M; Somarajan, S R; Srivastava, S K

    2010-06-01

    A recombinant leptospiral lipoprotein, LigB, was evaluated for use in the diagnosis of bovine leptospirosis by enzyme-linked immunosorbent assay (rLigB IgG ELISA). The standard reference test (Microscopic agglutination test, MAT) of 200 serum samples from cattle suspected of leptospirosis showed that 95 (47.5%) samples had positive agglutination titres, which ranged from 100 to 1600. In rLigB IgG ELISA, 49% of the samples were positive. Sensitivity of IgG ELISA for 95 bovine sera, which had MAT titres of greater than or equal to 100, were 100%. ELISA showed a specificity of 97.1% with 105 bovine sera, which were negative at a 1:50 dilution in MAT for Leptospira interrogans serovars. The results of ELISA and MAT correspond very good. When analytical specificity of IgG ELISA was evaluated using bovine serum samples from animals showing the serum antibodies to other pathogens, no cross-reaction was observed. Thus the recombinant LigB IgG ELISA can be used instead of the MAT as an aid to the diagnosis of bovine leptospirosis. Copyright 2009. Published by Elsevier India Pvt Ltd.

  15. A novel pooled-sample multiplex luminex assay for high-throughput measurement of relative telomere length.

    PubMed

    Jasmine, Farzana; Shinkle, Justin; Sabarinathan, Mekala; Ahsan, Habibul; Pierce, Brandon L; Kibriya, Muhammad G

    2018-03-12

    Relative telomere length (RTL) is a potential biomarker of aging and risk for chronic disease. Previously, we developed a probe-based RTL assay on Luminex platform, where probes for Telomere (T) and reference gene (R) for a given DNA sample were tested in a single well. Here, we describe a method of pooling multiple samples in one well to increase the throughput and cost-effectiveness. We used four different microbeads for the same T-probe and four different microbeads for the same R-probe. Each pair of probe sets were hybridized to DNA in separate plates and then pooled in a single plate for all the subsequent steps. We used DNA samples from 60 independent individuals and repeated in multiple batches to test the precision. The precision was good to excellent with Intraclass correlation coefficient (ICC) of 0.908 (95% CI 0.856-0.942). More than 67% of the variation in the RTL could be explained by sample-to-sample variation; less than 0.1% variation was due to batch-to-batch variation and 0.3% variation was explained by bead-to-bead variation. We increased the throughput of RTL Luminex assay from 60 to 240 samples per run. The new assay was validated against the original Luminex assay without pooling (r = 0.79, P = 1.44 × 10 -15 ). In an independent set of samples (n = 550), the new assay showed a negative correlation of RTL with age (r = -0.41), a result providing external validation for the method. We describe a novel high throughput pooled-sample multiplex Luminex assay for RTL with good to excellent precision suitable for large-scale studies. © 2018 Wiley Periodicals, Inc.

  16. Assessment of the Microbiological Safety of Precut Fruit from Retail and Catering Premises in the United Kingdom.

    PubMed

    Willis, Caroline; McLauchlin, Jim; Amar, Corinne; Sadler-Reeves, Lorraine; Elviss, Nicola; Aird, Heather; Fox, Andrew; Kaye, Moira

    2016-04-01

    Fresh fruit has been associated with a number of foodborne outbreaks in recent years. In particular, a large outbreak of listeriosis in the United States in 2011 was associated with consumption of cantaloupe melon, and an outbreak of Salmonella Newport in the United Kingdom and Europe (also in 2011) was linked to watermelon consumption. A study of precut fruit products from catering and retail premises in the United Kingdom was, therefore, carried out to assess their microbiological safety. Between January and March 2012, samples (1,188) of ready-to-eat precut fruit were collected from retail and catering premises in the United Kingdom, and 99% were of satisfactory microbiological quality. However, four samples (0.3%) were of an unsatisfactory quality (one with 800 CFU/g Listeria monocytogenes and three with >100 CFU/g Escherichia coli), and five samples (0.4%) were of a borderline quality owing to the presence of E. coli (two samples with a level of 20 CFU/g), Staphylococcus aureus (two samples with levels of >50 CFU/g), or L. monocytogenes (one sample with a level of 80 CFU/g). L. monocytogenes or other Listeria species were detected in a further 54 samples (4.5%) at levels below the threshold considered to be borderline or unsatisfactory. A significantly larger proportion of samples from one national supermarket chain was contaminated with L. monocytogenes than other supermarkets, and two types were, in this study, unique to this supermarket. This study shows that overall, the microbiological quality of ready-to-eat precut fruit was good. However, the presence of Listeria species in 5% of samples highlights the need for good hygiene during preparation and satisfactory temperature and time control during storage of these food products.

  17. Gamma-Ray Attenuation to Evaluate Soil Porosity: An Analysis of Methods

    PubMed Central

    Pires, Luiz F.; Pereira, André B.

    2014-01-01

    Soil porosity (ϕ) is of a great deal for environmental studies due to the fact that water infiltrates and suffers redistribution in the soil pore space. Many physical and biochemical processes related to environmental quality occur in the soil porous system. Representative determinations of ϕ are necessary due to the importance of this physical property in several fields of natural sciences. In the current work, two methods to evaluate ϕ were analyzed by means of gamma-ray attenuation technique. The first method uses the soil attenuation approach through dry soil and saturated samples, whereas the second one utilizes the same approach but taking into account dry soil samples to assess soil bulk density and soil particle density to determine ϕ. The results obtained point out a good correlation between both methods. However, when ϕ is obtained through soil water content at saturation and a 4 mm collimator is used to collimate the gamma-ray beam the first method also shows good correlations with the traditional one. PMID:24616640

  18. A Comparison of Three Different Scoring Methods for Self-Report Measures of Psychological Aggression in a Sample of College Females

    PubMed Central

    Shorey, Ryan C.; Brasfield, Hope; Febres, Jeniimarie; Cornelius, Tara L.; Stuart, Gregory L.

    2012-01-01

    Psychological aggression in females’ dating relationships has received increased empirical attention in recent years. However, researchers have used numerous measures of psychological aggression, and various scoring methods with these measures, making it difficult to compare across studies on psychological aggression. In addition, research has yet to examine whether different scoring methods for psychological aggression measures may affect the psychometric properties of these instruments. The current study examined three self-report measures of psychological aggression within a sample of female college students (N = 108), including their psychometric properties when scored using frequency, sum, and variety scores. Results showed that the Revised Conflict Tactics Scales (CTS2) had variable internal consistency depending on the scoring method used and good validity; the Multidimensional Measure of Emotional Abuse (MMEA) and the Follingstad Psychological Aggression Scale (FPAS) both had good internal consistency and validity across scoring methods. Implications of these findings for the assessment of psychological aggression and future research are discussed. PMID:23393957

  19. A comparison of three different scoring methods for self-report measures of psychological aggression in a sample of college females.

    PubMed

    Shorey, Ryan C; Brasfield, Hope; Febres, Jeniimarie; Cornelius, Tara L; Stuart, Gregory L

    2012-01-01

    Psychological aggression in females' dating relationships has received increased empirical attention in recent years. However, researchers' have used numerous measures of psychological aggression and various scoring methods with these measures, making it difficult to compare across studies on psychological aggression. In addition, research has yet to examine whether different scoring methods for psychological aggression measures may affect the psychometric properties of these instruments. This study examined three self-report measures of psychological aggression within a sample of female college students (N = 108), including their psychometric properties when scored using frequency, sum, and variety scores. Results showed that the Revised Conflict Tactics Scales (CTS2) had variable internal consistency depending on the scoring method used and good validity; the Multidimensional Measure of Emotional Abuse (MMEA) and the Follingstad Psychological Aggression Scale (FPAS) both had good internal consistency and validity across scoring methods. Implications of these findings for the assessment of psychological aggression and future research are discussed.

  20. Evaluation of the antioxidant power of honey, propolis and royal jelly by amperometric flow injection analysis.

    PubMed

    Buratti, S; Benedetti, S; Cosio, M S

    2007-02-28

    In this paper is described the applicability of a flow injection system, operating with an amperometric detector, for measurement in rapid and simple way the antioxidant power of honey, propolis and royal jelly. The proposed method evaluates the reducing power of selected antioxidant compounds and does not require the use of free radicals or oxidants. Twelve honey, 12 propolis and 4 royal jelly samples of different botanical and geographical origin were evaluated by the electrochemical method and the data were compared with those obtained by the DPPH assay. Since a good correlation was found (R(2)=0.92) the proposed electrochemical method can be successfully employed for the direct, rapid and simple monitoring of the antioxidant power of honeybee products. Furthermore, the total phenolic content of samples was determined by the Folin-Ciocalteau procedure and the characteristic antioxidant activities showed a good correlation with phenolics (R(2)=0.96 for propolis and 0.90 for honey).

  1. Preparation and performance study of a novel liquid scintillator with mixed solvent as the matrix

    NASA Astrophysics Data System (ADS)

    Zheng, Zhanlong; Zhu, Jiayi; Luo, Xuan; Xu, Yewei; Zhang, Qianfeng; Zhang, Xing; Bi, Yutie; Zhang, Lin

    2017-04-01

    A novel liquid scintillator with the mixed solvent as the matrix was prepared for obtaining a good comprehensive performance. In this ternary liquid scintillator, the combination of 20% pseudocumene (PC) and 80% linear-alkyl benzene (LAB) by volume was chosen as the mixed solvent, and 2,5-diphenyloxazole (PPO) and 1,4-bis(2-Methylstyryl) benzene (bis-MSB) were as the primary fluor and wavelength shifter, respectively. The optimum prescription was obtained with regard to the light yield. Some characterizations based on the optimal formulation were conducted. The fluorescence emission spectra and wavelength-dependent optical attenuation length of the sample were measured by the fluorescence spectrophotometer and an UV-Vis spectrometer, respectively. The light yield was characterized by adopting the home-made optical platform device. The decay time was tested by adopting the time-correlated single photon counting (TCSPC) technique featured in high dynamic range of several orders of magnitude in light intensity. The experimental test results showed that the sample had a fairly good comprehensive performance.

  2. Application of FTIR-ATR spectroscopy to the quantification of sugar in honey.

    PubMed

    Anjos, Ofélia; Campos, Maria Graça; Ruiz, Pablo Contreras; Antunes, Paulo

    2015-02-15

    A Fourier transform infrared spectroscopic method with attenuated total reflectance (FTIR-ATR) and partial least squares (PLS) regression model for the prediction of sugar content in honey samples was calculated. Standards of trehalose, glucose, fructose, sucrose, melezitose, turanose and maltose were used to identify and quantify the individual sugar components in 63 honey samples by HPAEC-IPAD. Fructose and glucose are the highest sugars in honey with an average value of 36% and 26%, respectively. The 1stDer spectra with MSC or SLS in the wave number range from 1500 to 750cm(-1) provide the best calibration model with a r(2) of 86.60 and 86.01 with RPD of 2.6 and 2.55, respectively for fructose and glucose. For turanose and melezitose good models were also found. The FTIR-ATR showed to be a good methodology to quantify the main sugar content in honey and easily adapted to routine analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Comparative Performance of Reagents and Platforms for Quantitation of Cytomegalovirus DNA by Digital PCR

    PubMed Central

    Gu, Z.; Sam, S. S.; Sun, Y.; Tang, L.; Pounds, S.; Caliendo, A. M.

    2016-01-01

    A potential benefit of digital PCR is a reduction in result variability across assays and platforms. Three sets of PCR reagents were tested on two digital PCR systems (Bio-Rad and RainDance), using three different sets of PCR reagents for quantitation of cytomegalovirus (CMV). Both commercial quantitative viral standards and 16 patient samples (n = 16) were tested. Quantitative accuracy (compared to nominal values) and variability were determined based on viral standard testing results. Quantitative correlation and variability were assessed with pairwise comparisons across all reagent-platform combinations for clinical plasma sample results. The three reagent sets, when used to assay quantitative standards on the Bio-Rad system, all showed a high degree of accuracy, low variability, and close agreement with one another. When used on the RainDance system, one of the three reagent sets appeared to have a much better correlation to nominal values than did the other two. Quantitative results for patient samples showed good correlation in most pairwise comparisons, with some showing poorer correlations when testing samples with low viral loads. Digital PCR is a robust method for measuring CMV viral load. Some degree of result variation may be seen, depending on platform and reagents used; this variation appears to be greater in samples with low viral load values. PMID:27535685

  4. Magnetic micro-solid-phase extraction based on magnetite-MCM-41 with gas chromatography-mass spectrometry for the determination of antidepressant drugs in biological fluids.

    PubMed

    Kamaruzaman, Sazlinda; Sanagi, Mohd Marsin; Yahaya, Noorfatimah; Wan Ibrahim, Wan Aini; Endud, Salasiah; Wan Ibrahim, Wan Nazihah

    2017-11-01

    A new facile magnetic micro-solid-phase extraction coupled to gas chromatography and mass spectrometry detection was developed for the extraction and determination of selected antidepressant drugs in biological fluids using magnetite-MCM-41 as adsorbent. The synthesized sorbent was characterized by several spectroscopic techniques. The maximum extraction efficiency for extraction of 500 μg/L antidepressant drugs from aqueous solution was obtained with 15 mg of magnetite-MCM-41 at pH 12. The analyte was desorbed using 100 μL of acetonitrile prior to gas chromatography determination. This method was rapid in which the adsorption procedure was completed in 60 s. Under the optimized conditions using 15 mL of antidepressant drugs sample, the calibration curve showed good linearity in the range of 0.05-500 μg/L (r 2  = 0.996-0.999). Good limits of detection (0.008-0.010 μg/L) were obtained for the analytes with good relative standard deviations of <8.0% (n = 5) for the determination of 0.1, 5.0, and 500.0 μg/L of antidepressant drugs. This method was successfully applied to the determination of amitriptyline and chlorpromazine in plasma and urine samples. The recoveries of spiked plasma and urine samples were in the range of 86.1-115.4%. Results indicate that magnetite micro-solid-phase extraction with gas chromatography and mass spectrometry is a convenient, fast, and economical method for the extraction and determination of amitriptyline and chlorpromazine in biological samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. In-tube solid-phase microextraction based on NH2-MIL-53(Al)-polymer monolithic column for online coupling with high-performance liquid chromatography for directly sensitive analysis of estrogens in human urine.

    PubMed

    Luo, Xialin; Li, Gongke; Hu, Yufei

    2017-04-01

    In this work, a novel NH 2 -MIL-53(Al) incorporated poly(styrene-divinylbenzene-methacrylic acid) (poly(St-DVB-MAA)) monolith was prepared via chemical fabrication. Moreover, it has been efficiently applied to the in-tube solid-phase microextraction (SPME) for online coupling with high-performance liquid chromatography (HPLC) to the direct determination of five estrogens in human urine samples. The NH 2 -MIL-53(Al)-polymer monolith was suitable for in-tube SPME owing to its good permeability, high extraction efficiency, chemical stability, good reproducibility and long lifetime. The extraction conditions including extraction solvent, pH of sample solution, flow rate of extraction and desorption, and desorption volume were investigated. Under the optimum conditions, the enrichment factors were 180-304 and saturated amounts of extraction were 2326-21393 pmol for estriol, 17β-estradiol, estrone, ethinyl estradiol and progesterone, respectively. The adsorption mechanism was also explored which contributed to its strong extraction to target compounds. The proposed method had low limit of detection (2.0-40ng/L) and good linearity (with R 2 between 0.9908 and 0.9978). Four endogenous estrogens were detected in urine samples and the recoveries of all five analytes were ranged from 75.1-120% with relative standard deviations (RSDs) less than 8.7%. The results showed that the proposed online SPME-HPLC method based on NH 2 -MIL-53(Al)-polymer monolithic column was highly sensitive for directly monitoring trace amount of estrogens in human urine sample. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Separation and screening of short-chain chlorinated paraffins in environmental samples using comprehensive two-dimensional gas chromatography with micro electron capture detection.

    PubMed

    Xia, Dan; Gao, Lirong; Zhu, Shuai; Zheng, Minghui

    2014-11-01

    Short-chain chlorinated paraffins (SCCPs) are highly complex technical mixtures with thousands of isomers and numerous homologs. They are classified as priority candidate persistent organic pollutants under the Stockholm Convention for their persistence, bioaccumulation, and toxicity. Analyzing SCCPs is challenging because of the complexity of the mixtures. Chromatograms of SCCPs acquired using one-dimensional (1D) gas chromatography (GC) contain a large characteristic "peak" with a broad and unresolved profile. Comprehensive two-dimensional GC (GC×GC) shows excellent potential for separating complex mixtures. In this study, GC×GC coupled with micro electron capture detection (μECD) was used to separate and screen SCCPs. The chromatographic parameters, including the GC column types, oven temperature program, and modulation period, were systematically optimized. The SCCP congeners were separated into groups using a DM-1 column connected to a BPX-50 column. The SCCP congeners in technical mixtures were separated according to the number of chlorine substituents for a given carbon chain length and according to the number of carbon atoms plus chlorine atoms for different carbon chain lengths. A fish tissue sample was analyzed to illustrate the feasibility of the GC×GC-μECD method in analyzing biological samples. Over 1,500 compounds were identified in the fish extract, significantly more than were identified using 1D GC. The detection limits for five selected SCCP congeners were between 1 and 5 pg/L using the GC×GC method, and these were significantly lower than those achieved using 1D GC. This method is a good choice for analysis of SCCPs in environmental samples, exhibiting good separation and good sensitivity.

  7. The Effect of Nano Loading and Ultrasonic Compounding of EVA/LDPE/Nano-magnesium Hydroxide on Mechanical Properties and Distribution of Nano Particles

    NASA Astrophysics Data System (ADS)

    Azman, I. A.; Salleh, R. M.; Alauddin, S. M.; Shueb, M. I.

    2018-05-01

    Blends of Ethylene Vinyl Acetate (EVA) and Low-Density Polyethylene (LDPE) are promising composite which have good mechanical properties to environmental stress cracking. However, they lack fire resistant properties, which limits it usage in wire and cable industry. In order to improve flame retardancy ability, a range of nano-magnesium hydroxide (nano-MH) loading which is from 0 phr to maximum of 20 phr with ultrasonic extrusion 0-100 kHz frequencies have been introduced. Ultrasonic extrusion was used to improve the distribution of nano-MH. It was found that, 10 phr of nano loading with 100 kHz ultrasonic assisted has greater tensile strength compared to the nanocomposite without ultrasonication. Further increase of nano MH loading, will decrease the tensile properties. Better elongation at break was observed at10 phr nano-MH with the frequency of 50 kHz. The sample of 20 phr of nanoMH assisted with 50 kHz ultrasonic exhibits good flexural properties while 10 phr of nano-MH without the ultrasonic assisted demonstrates good in izod impact properties. From the evaluation of mechanical properties studied, it was found that 10 phr of nano-MH has shown the best performance among all the samples tested for EVA/LDPE/nano-MH composites. Transmission Electron Microscopy (TEM) has been conducted on 10 phr sample with different frequencies in order to observe the distribution of nano-MH particles. The sample with 100 kHz frequency shows more uniform dispersion of nano-MH in EVA/LDPE composites. This investigation indicates that the ultrasonic technology can enhance the mechanical properties studied as well as the dispersion of nano particles in the composite.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kiradzhiyska, D. D., E-mail: denica.kiradjiiska@gmail.com; Mantcheva, R. D., E-mail: r-manch@abv.bg; Feodorova, Y. N.

    Materials for medical implants should have suitable mechanical properties, excellent biocompatibility and high corrosion resistance. They should not stimulate allergic and immunologic reactions and should not cause cancer. The use of aluminum as a construction material in implantology is continuously expanding. There are various methods for surface treatment to improve its biocompatibility. In this study aluminum samples anodized in 15% H{sub 2} SO{sub 4} or treated with positive or negative corona discharge were investigated. PDL-cell line of immortalized cells, precursors of periodontal ligament and RAW 264.7 cell line from mouse macrophages are used for the bioassays. The results show thatmore » 10 and 20 μm thick oxide film provides better development of the PLD cells, compared to untreated aluminum. Metal surfaces with 10 μm thick oxide film show the best properties in terms of cells vitality, proliferation and growth. Polymer treated but uncharged samples show good results.« less

  9. INAA Application for Trace Element Determination in Biological Reference Material

    NASA Astrophysics Data System (ADS)

    Atmodjo, D. P. D.; Kurniawati, S.; Lestiani, D. D.; Adventini, N.

    2017-06-01

    Trace element determination in biological samples is often used in the study of health and toxicology. Determination change to its essentiality and toxicity of trace element require an accurate determination method, which implies that a good Quality Control (QC) procedure should be performed. In this study, QC for trace element determination in biological samples was applied by analyzing the Standard Reference Material (SRM) Bovine muscle 8414 NIST using Instrumental Neutron Activation Analysis (INAA). Three selected trace element such as Fe, Zn, and Se were determined. Accuracy of the elements showed as %recovery and precision as %coefficient of variance (%CV). The result showed that %recovery of Fe, Zn, and Se were in the range between 99.4-107%, 92.7-103%, and 91.9-112%, respectively, whereas %CV were 2.92, 3.70, and 5.37%, respectively. These results showed that INAA method is precise and accurate for trace element determination in biological matrices.

  10. Transcriptional profiling of cork oak phellogenic cells isolated by laser microdissection.

    PubMed

    Teixeira, Rita Teresa; Fortes, Ana Margarida; Bai, Hua; Pinheiro, Carla; Pereira, Helena

    2018-02-01

    The phenylpropanoid pathway impacts the cork quality development. In cork of bad quality, the flavonoid route is favored, whereas in good quality, cork lignin and suberin production prevails. Cork oaks develop a thick cork tissue as a protective shield that results of the continuous activity of a secondary meristem, the cork cambium, or phellogen. Most studies applied to developmental processes do not consider the cell types from which the samples were extracted. Here, laser microdissection (LM) coupled with transcript profiling using RNA sequencing (454 pyrosequencing) was applied to phellogen cells of trees producing low- and good quality cork. Functional annotation and functional enrichment analyses showed that stress-related genes are enriched in samples extracted from trees producing good quality cork (GQC). This process is under tight transcriptional (transcription factors, kinases) regulation and also hormonal control involving ABA, ethylene, and auxins. The phellogen cells collected from trees producing bad quality cork (BQC) show a consistent up-regulation of genes belonging to the flavonoid pathway as a response to stress. They also display a different modulation of cell wall genes resulting into a thinner cork layer, i.e., less meristematic activity. Based on the analysis of the phenylpropanoid pathway regulating genes, in GQC, the synthesis of lignin and suberin is promoted, whereas in BQC, the same pathway favors the biosynthesis of free phenolic compounds. This study provided new insights of how cell-specific gene expression can determine tissue and organ morphology and physiology and identified robust candidate genes that can be used in breeding programs aiming at improving cork quality.

  11. Goodness-of-Fit Tests for Generalized Normal Distribution for Use in Hydrological Frequency Analysis

    NASA Astrophysics Data System (ADS)

    Das, Samiran

    2018-04-01

    The use of three-parameter generalized normal (GNO) as a hydrological frequency distribution is well recognized, but its application is limited due to unavailability of popular goodness-of-fit (GOF) test statistics. This study develops popular empirical distribution function (EDF)-based test statistics to investigate the goodness-of-fit of the GNO distribution. The focus is on the case most relevant to the hydrologist, namely, that in which the parameter values are unidentified and estimated from a sample using the method of L-moments. The widely used EDF tests such as Kolmogorov-Smirnov, Cramer von Mises, and Anderson-Darling (AD) are considered in this study. A modified version of AD, namely, the Modified Anderson-Darling (MAD) test, is also considered and its performance is assessed against other EDF tests using a power study that incorporates six specific Wakeby distributions (WA-1, WA-2, WA-3, WA-4, WA-5, and WA-6) as the alternative distributions. The critical values of the proposed test statistics are approximated using Monte Carlo techniques and are summarized in chart and regression equation form to show the dependence of shape parameter and sample size. The performance results obtained from the power study suggest that the AD and a variant of the MAD (MAD-L) are the most powerful tests. Finally, the study performs case studies involving annual maximum flow data of selected gauged sites from Irish and US catchments to show the application of the derived critical values and recommends further assessments to be carried out on flow data sets of rivers with various hydrological regimes.

  12. Powdered activated carbons as effective phases for bar adsorptive micro-extraction (BAμE) to monitor levels of triazinic herbicides in environmental water matrices.

    PubMed

    Neng, N R; Mestre, A S; Carvalho, A P; Nogueira, J M F

    2011-02-15

    Bar adsorptive micro-extraction using three powdered activated carbons (ACs) as adsorbent phases followed by liquid desorption and high performance liquid chromatography with diode array detection (BAμE(ACs)-LD/HPLC-DAD), was developed to monitor triazinic herbicides (atrazine, simazine and terbutylazine) in environmental water matrices. ACs used present apparent surface areas around 1000 m(2) g(-1) with an important mesoporous volume and distinct surface chemistry characteristics (pH(PZC) ranging from 6.5 to 10.4). The textural and surface chemistry properties of the ACs adsorbent phases were correlated with the analytical data for a better understanding of the overall enrichment process. Assays performed on 10 mL water samples spiked at the 10.0 μg L(-1) levels under optimized experimental conditions yielded recoveries around 100% for the three herbicides under study. The analytical performance showed good precision (RSD<15.0%), convenient detection limits (≈0.1 μg L(-1)) and suitable linearity (1.0-12.0 μg L(-1)) with good correlation coefficients (r(2)>0.9914). By using the standard addition method, the application of the present method on real water matrices, such as surface water and wastewater, allowed very good performances at the trace level. The proposed methodology proved to be a suitable sorptive extraction alternative for the analysis of priority pollutants with polar characteristics, showing to be easy to implement, reliable, sensitive and requiring a low sample volume to monitor triazinic compounds in water matrices. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. The effect of noble metal additives on the optimum operating temperature of SnO2 gas sensors

    NASA Astrophysics Data System (ADS)

    Mohammad-Yousefi, S.; Rahbarpour, S.; Ghafoorifard, H.

    2017-12-01

    The effect of Pd and Au additives on gas sensing properties of SnO2 was investigated. SnO2 pallets were fabricated and sintered at 900 °C for 90 minutes. Several nanometer layers of Pd and Au were deposited on separate SnO2 pallets and were intentionally dispersed into the SnO2 pallets by long heat treatment (400 °C for 1 Day). All metal loaded samples showed significant enhancement in response level and optimum operating temperature compare to pure SnO2 gas sensors. The amount of enhancement was strongly dependent on the material and the thickness of deposited metal layer. Studying butanol response showed that increasing the thickness of metal causes the response level to increase. Further thickness increase caused contrary effect and decreased the performance of sensors. Best results were achieved at 10 nm-thick Au and 7 nm-thick Pd. Generally, Pd-SnO2 samples demonstrated better performance than Au-SnO2 ones, however, Au-SnO2 samples were proved to be good candidate to sense reducing gases with lower hydrogen atoms in their formula. Given experimental results were also good evidence of chemical activity of gold and simply confirms the relation between chemical activity and gold particle size. Results were qualitatively described by gas diffusion theory and surface reactions take place on metal particles.The first section in your paper

  14. Development of structure switching aptamer assay for detection of aflatoxin M1 in milk sample.

    PubMed

    Sharma, Atul; Catanante, Gaëlle; Hayat, Akhtar; Istamboulie, Georges; Ben Rejeb, Ines; Bhand, Sunil; Marty, Jean Louis

    2016-09-01

    The discovery of in-vitro systematic evolution of ligands by exponential enrichment (SELEX) process has considerably broaden the utility of aptamer as bio-recognition element, providing the high binding affinity and specificity against the target analytes. Recent research has focused on the development of structure switching signaling aptamer assay, transducing the aptamer- target recognition event into an easily detectable signal. In this paper, we demonstrate the development of structure switching aptamer assay for determination of aflatoxin M1 (AFM1) employing the quenching-dequenching mechanism. Hybridization of fluorescein labelled anti-AFM1 aptamer (F-aptamer) with TAMRA labelled complementary sequences (Q-aptamer) brings the fluorophore and the quencher into close proximity, which results in maximum fluorescence quenching. On addition of AFM1, the target induced conformational formation of antiparallel G-quadruplex aptamer-AFM1 complex results in fluorescence recovery. Under optimized experimental conditions, the developed method showed the good linearity with limit of detection (LOD) at 5.0ngkg(-1) for AFM1. The specificity of the sensing platform was carefully investigated against aflatoxin B1 (AFB1) and ochratoxin A (OTA). The developed assay platform showed the high specificity towards AFM1. The practical application of the developed aptamer assay was verified for detection of AFM1 in spiked milk samples. Good recoveries were obtained in the range from 94.40% to 95.28% (n=3) from AFM1 spiked milk sample. Copyright © 2016. Published by Elsevier B.V.

  15. Observation of tendon repair in animal model using second-harmonic-generation microscopy

    NASA Astrophysics Data System (ADS)

    Hase, Eiji; Minamikawa, Takeo; Sato, Katsuya; Takahashi, Mitsuhiko; Yasui, Takashi

    2016-03-01

    Tendon rupture is a trauma difficult to recover the condition before injury. In previous researches, tensile test and staining method have been widely used to elucidate the mechanism of the repair process from the viewpoints of the mechanical property and the histological findings. However, since both methods are destructive and invasive, it is difficult to obtain both of them for the same sample. If both the mechanical property and the histological findings can be obtained from the same sample, one may obtain new findings regarding mechanisms of tendon repairing process. In this paper, we used second-harmonic-generation (SHG) microscopy, showing high selectivity and good image contrast to collagen molecules as well as high spatial resolution, optical three-dimensional sectioning, deep penetration, and without additional staining. Since SHG light intensity sensitively reflects the structural maturity of collagen molecule and its aggregates, it will be a good indicator for the repairing degree of the ruptured tendon. From comparison of SHG images between the 4-weeks-repaired tendon and the sound tendon in the animal model, we confirmed that SHG light intensity of the repaired tendon was significantly lower than that of the sound tendon, indicating that the collagen structure in the repaired tendon is still immature. Furthermore, we performed both SHG imaging and the tensile test for the same sample, and confirmed a correlation between them. This result shows a potential of SHG light for an indicator of the histological and mechanical recovery of the ruptured tendon.

  16. A monolithic column based on covalent cross-linked polymer gels for online extraction and analysis of trace aflatoxins in food sample.

    PubMed

    Wei, Tianfu; Chen, Zhengyi; Li, Gongke; Zhang, Zhuomin

    2018-05-04

    Aflatoxins are highly toxic mycotoxin contamination, which pose serious food safety incidents. It is very important to precisely and rapidly determine trace aflatoxins in food. In this study, we designed porous monolithic column based on covalent cross-linked polymer gels for online extraction and analysis of trace aflatoxins in food samples with complicated matrices coupled with high-performance liquid chromatography-ultraviolet detector (HPLC-UV). The prepared monolithic column showed excellent enrichment performance due to its good permeability, good reproducibility and long life span. The study of adsorption mechanism suggested that the excellent enrichment performance of this monolithic column was attributed to the multiple effect of π-π stacking interaction, hydrophobic effect and steric effect. When the online analytical method was applied for the determine of trace aflatoxins in real food samples, aflatoxins G 1 and aflatoxins B 1 could be actually found in one positive bean sauce sample and quantified to be 32.8 and 26.4 μg/kg, respectively. Aflatoxins G 1 in one bean sample could be also found and quantified to be 25.9 μg/kg. The low detection limits of the developed method were achieved in range of 0.08-0.2 μg/kg. And the recoveries for spiked samples were in range from 76.1 to 113% with RSDs of 1.1-9.6%. The developed method was proved to be a promising method for online enrichment and analysis of trace aflatoxins in complicated food samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Using CRANID to test the population affinity of known crania.

    PubMed

    Kallenberger, Lauren; Pilbrow, Varsha

    2012-11-01

    CRANID is a statistical program used to infer the source population of a cranium of unknown origin by comparing its cranial dimensions with a worldwide craniometric database. It has great potential for estimating ancestry in archaeological, forensic and repatriation cases. In this paper we test the validity of CRANID in classifying crania of known geographic origin. Twenty-three crania of known geographic origin but unknown sex were selected from the osteological collections of the University of Melbourne. Only 18 crania showed good statistical match with the CRANID database. Without considering accuracy of sex allocation, 11 crania were accurately classified into major geographic regions and nine were correctly classified to geographically closest available reference populations. Four of the five crania with poor statistical match were nonetheless correctly allocated to major geographical regions, although none was accurately assigned to geographically closest reference samples. We conclude that if sex allocations are overlooked, CRANID can accurately assign 39% of specimens to geographically closest matching reference samples and 48% to major geographic regions. Better source population representation may improve goodness of fit, but known sex-differentiated samples are needed to further test the utility of CRANID. © 2012 The Authors Journal of Anatomy © 2012 Anatomical Society.

  18. A 7-item version of the fatigue severity scale has better psychometric properties among HIV-infected adults: an application of a Rasch model.

    PubMed

    Lerdal, Anners; Kottorp, Anders; Gay, Caryl; Aouizerat, Bradley E; Portillo, Carmen J; Lee, Kathryn A

    2011-11-01

    To examine the psychometric properties of the 9-item Fatigue Severity Scale (FSS) using a Rasch model application. A convenience sample of HIV-infected adults was recruited, and a subset of the sample was assessed at 6-month intervals for 2 years. Socio-demographic, clinical, and symptom data were collected by self-report questionnaires. CD4 T-cell count and viral load measures were obtained from medical records. The Rasch analysis included 316 participants with 698 valid questionnaires. FSS item 2 did not advanced monotonically, and items 1 and 2 did not show acceptable goodness-of-fit to the Rasch model. A reduced FSS 7-item version demonstrated acceptable goodness-of-fit and explained 61.2% of the total variance in the scale. In the FSS-7 item version, no uniform Differential Item Functioning was found in relation to time of evaluation or to any of the socio-demographic or clinical variables. This study demonstrated that the FSS-7 has better psychometric properties than the FSS-9 in this HIV sample and that responses to the different items are comparable over time and unrelated to socio-demographic and clinical variables.

  19. How incidental values from the environment affect decisions about money, risk, and delay.

    PubMed

    Ungemach, Christoph; Stewart, Neil; Reimers, Stian

    2011-02-01

    How different are £0.50 and £1.50, "a small chance" and "a good chance," or "three months" and "nine months"? Our studies show that people behave as if the differences between these values are altered by incidental everyday experiences. Preference for a £1.50 lottery rather than a £0.50 lottery was stronger among individuals exposed to intermediate supermarket prices than among those exposed to lower or higher prices. Preference for "a good chance" rather than "a small chance" of winning a lottery was stronger among participants who predicted intermediate probabilities of rain than among those who predicted lower or higher chances of rain. Preference for consumption in "three months" rather than "nine months" was stronger among participants who planned for an intermediate birthday than among participants who planned for a sooner or later birthday. These fluctuations directly challenge economic accounts that translate monies, risks, and delays into subjective equivalents with stable functions. The decision-by-sampling model-in which subjective values are rank positions constructed from comparisons with samples-predicts these effects and indicates a primary role for sampling in decision making.

  20. Accurate determination of residual acrylic acid in superabsorbent polymer of hygiene products by headspace gas chromatography.

    PubMed

    Zhang, Shu-Xin; Chai, Xin-Sheng; Jiang, Ran

    2017-02-17

    This work reports on a method for the determination of residual acrylic acid (AA) in the superabsorbent polymers for hygiene products by headspace analysis. It was based on water extraction for the polymer sample at a room temperature for 50min. Then, the AA in the extractant reacted with bicarbonate solution in a closed headspace sample vial, from which the carbon dioxide generated from the reaction (within 20min at 70°C) was detected by gas chromatography (GC). It was found that there is adsorption partition equilibrium of AA between solid-liquid phases. Therefore, an equation for calculating the total AA content in the original polymers sample was derived based on the above phase equilibrium. The results show that the HS-GC method has good precision (RSD<2.51%) and good accuracy (recoveries from 93 to 105%); the limit of quantification (LOQ) was 373mg/kg. The present method is rapid, accurate, and suitable for determining total residual acrylic acid in a wide variety of applications from processing of superabsorbent polymer to commercial products quality control. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. School Social Behavior Scales: an adaptation study of the Portuguese version of the social competence scale from SSBS-2.

    PubMed

    Raimundo, Raquel; Carapito, Elsa; Pereira, Ana Isabel; Marques Pinto, Alexandra; Lima, Maria Luísa; Ribeiro, Maria Teresa

    2012-11-01

    This study analyses the psychometric proprieties of a Portuguese version of the social competence scale from the School Social Behavior Scales (SSBS-2, Merrell, 2002). It is a rating instrument of children and adolescents behavior, to be used by teachers and other school personnel. This scale includes 3 subscales: self-management/compliance, peer relations and academic behavior. In our first sample, 175 teachers rated 344 students from grade 1 through 12. On the second sample 13 teachers rated 251 3rd and 4th grades students. The results from the Portuguese adaptation support the multidimensional structure of the social competence scale from the SSBS-2, although an alternative model demonstrated a better fit to the data than the model originally proposed by the author. The scale showed good internal consistency and good intercorrelations between subscales, as well as between subscales and the total scale. The final model was well replicated in the second sample. These results encourage us to pursue the SSBS-2 Portuguese adaptation, in order to provide a useful and validated instrument for the assessment of social competence and for educational interventions.

  2. An improved RT-IPCR for detection of pyrene and related polycyclic aromatic hydrocarbons.

    PubMed

    Meng, X Y; Li, Y S; Zhou, Y; Sun, Y; Qiao, B; Si, C C; Hu, P; Lu, S Y; Ren, H L; Liu, Z S; Qiu, H J; Liu, J Q

    2016-04-15

    Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous homogeneous chemicals which are well known by carcinogens, mutagens and endocrine disorder. Here, an improved real-time immuno-PCR (RT-IPCR) was developed for detection of pyrene and its homologs in water samples. The PAHs in sample compete with pyrene-modified DNA to bind with monoclonal antibody (McAb) coated on PCR plate. The reporter DNA was exponentially amplified by real-time PCR instrument using Fast Start universal SYBR Green Master (ROX) kit. Only two reaction steps were needed to accomplish the detection. The assay had a good linear range from 5 pmol L(-1) to 5 nmol L(-1) with a detection limit of 3.5 pmol L(-1). For application assay, the average recoveries from tap water, lake water and mineral water were 98.4%, 98.2% and 99.7%, respectively which showed a good correlation (R(2)=0.9906) with those from GC-MS. The results indicated that the improved RT-IPCR seems to be a potential method for simple and ultrasensitive detection of pyrene and some homologues in environment water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Preparation of sulfonated graphene/polypyrrole solid-phase microextraction coating by in situ electrochemical polymerization for analysis of trace terpenes.

    PubMed

    Zhang, Chengjiang; Zhang, Zhuomin; Li, Gongke

    2014-06-13

    In this study, a novel sulfonated graphene/polypyrrole (SG/PPy) solid-phase microextraction (SPME) coating was prepared and fabricated on a stainless-steel wire by a one-step in situ electrochemical polymerization method. Crucial preparation conditions were optimized as polymerization time of 15min and SG doping amount of 1.5mg/mL. SG/PPy coating showed excellent thermal stability and mechanical durability with a long lifespan of more than 200 stable replicate extractions. SG/PPy coating demonstrated higher extraction selectivity and capacity to volatile terpenes than commonly-used commercial coatings. Finally, SG/PPy coating was practically applied for the analysis of volatile components from star anise and fennel samples. The majority of volatile components identified were terpenes, which suggested the ultra-high extraction selectivity of SG/PPy coating to terpenes during real analytical projects. Four typical volatile terpenes were further quantified to be 0.2-27.4μg/g from star anise samples with good recoveries of 76.4-97.8% and 0.1-1.6μg/g from fennel samples with good recoveries of 80.0-93.1%, respectively. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Micro-injector for capillary electrophoresis.

    PubMed

    Sáiz, Jorge; Koenka, Israel Joel; García-Ruiz, Carmen; Müller, Beat; Chwalek, Thomas; Hauser, Peter C

    2015-08-01

    A novel micro-injector for capillary electrophoresis for the handling of samples with volumes down to as little as 300 nL was designed and built in our laboratory for analyses in which the available volume is a limitation. The sample is placed into a small cavity located directly in front of the separation capillary, and the injection is then carried out automatically by controlled pressurization of the chamber with compressed air. The system also allows automated flushing of the injection chamber as well as of the capillary. In a trial with a capillary electrophoresis system with contactless conductivity detector, employing a capillary of 25 μm diameter, the results showed good stability of migration times and peak areas. To illustrate the technique, the fast separation of five inorganic cations (Na(+) , K(+) , NH4 (+) , Ca(2+) , and Mg(2+) ) was set up. This could be achieved in less than 3 min, with good limits of detection (10 μM) and linear ranges (between about 10 and 1000 μM). The system was demonstrated for the determination of the inorganic cations in porewater samples of a lake sediment core. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Comparative evaluation of methods for the determination of heat transfer coefficients of liquid and gaseous quenching media

    NASA Astrophysics Data System (ADS)

    Shevchenko, Svetlana Yu.; Melnik, Yury A.; Smirnov, Andrey E.; Htet, Wai Yan Min

    2018-03-01

    Temperature dependences of heat transfer coefficients of liquid and gaseous quenching media were determined using a gradient probe and prismatic probe of more simple design. The probes of two different designs were tested in the same conditions. Analysis of heat transfer coefficients showed good agreement between the data obtained. The tests were carried out with liquid and gaseous quenching media: water, polymer quenchant, quenching oil and high-pressure nitrogen. Methods of mathematical modeling of steel samples quenching show the adequacy of the results.

  6. Pesticides in agricultural headwater streams in southwestern Germany and effects on macroinvertebrate populations.

    PubMed

    Weber, Gero; Christmann, Nicole; Thiery, Ann-Cathrin; Martens, Dieter; Kubiniok, Jochen

    2018-04-01

    Pesticides are a major burden for stream ecosystems in the central European cultivated landscape. The objective of the present study was to investigate the applicability of ecological indicator methods in relation to toxicity of pesticides under the specific hydro-morphological conditions in small water bodies. Thus, an association of toxicity evaluating methods with different ecological indicators was to be attempted. Based on three random samples taken within the 2016 vegetation period, 23 headwater areas in the Saarland were investigated to test for pesticides and their metabolites. The macroinvertebrate population was also surveyed in 16 of these streams. Evidence was found of 41 substances in total. Most dominant substances include atrazine, isoproturone, quinmerac and tebuconazol as well as metabolites of dimethenamid, chloridazon and metazachlor. At 9 of the 23 sampling points, over 10 plant protection products and metabolites were found. Only 17% of the water bodies investigated contained fewer than 5 substances. Around half of the bodies of water investigated show noticeably high concentrations of metabolites of plant protection products. Maximum concentrations exceeding environmental quality standards or the Health-oriented Guideline Values were measured for 13 substances at individual sampling points. Analysis of the biological data for only 4 of the water bodies investigated resulted in the Ecological Status Class (ESC) "good". All others fell short of the quality target, although they were classified as "good" or "very good" according to the Saprobic index. SPEAR pesticides as a measurement of the sensitivity of the biocoenosis to pesticides shows their influence in a few water bodies. Likewise, high toxic unit values have also been calculated, indicating the presence of toxic substances at relevant concentrations. However, an actual correlation between SPEAR pesticides and toxic unit could not be derived. Clearly in these very headwater streams other habitat-determining hydromorphological factors overlay the toxic impact of pesticides. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Ultrasonic Determination of the Elastic Constants of Epoxy-natural Fiber Composites

    NASA Astrophysics Data System (ADS)

    Valencia, C. A. Meza; Pazos-Ospina, J. F.; Franco, E. E.; Ealo, Joao L.; Collazos-Burbano, D. A.; Garcia, G. F. Casanova

    This paper shows the applications ultrasonic through-transmission technique to determine the elastic constants of two polymer-natural fiber composite materials with potential industrial application and economic and environmental advantages. The transversely isotropic coconut-epoxy and fique-epoxy samples were analyzed using an experimental setup which allows the sample to be rotated with respect to transducers faces and measures the time-of-flight at different angles of incidence. Then, the elastic properties of the material were obtained by fitting the experimental data to the Christoffel equation. Results show a good agreement between the measured elastic constants and the values predicted by an analytical model. The velocities as a function of the incidence angle are reported and the effect of the natural fiber on the stiffness of the composite is discussed.

  8. Scanning Auger Microprobe and atomic absorption studies of lunar volcanic volatiles

    NASA Technical Reports Server (NTRS)

    Cirlin, E. H.; Housley, R. M.

    1979-01-01

    Results on lunar volatile transport processes have been obtained by studying green and brown glass droplets, orange and black core tube samples and the surface sample 74241 with the Scanning Auger Microprobe (SAM) and by Flameless Atomic Absorption Analysis (FLAA). SAM analyses show that the most dominant volatiles in the top few atomic layers of droplets are Zn and S, confirming that the surface Zn and S are good indicators of pyroclastic origin, and they are not entirely present as ZnS. In addition, FLAA thermal release profiles show that almost all the Zn and Cd are on grain surfaces, indicating that Zn and Cd were completely outgassed from lava fountain products during the volcanic eruption, were recondensed during or after the eruptions, and are thus present as surface coating.

  9. Conductance switching in Ag(2)S devices fabricated by in situ sulfurization.

    PubMed

    Morales-Masis, M; van der Molen, S J; Fu, W T; Hesselberth, M B; van Ruitenbeek, J M

    2009-03-04

    We report a simple and reproducible method to fabricate switchable Ag(2)S devices. The alpha-Ag(2)S thin films are produced by a sulfurization process after silver deposition on an Si substrate. Structure and composition of the Ag(2)S are characterized using XRD and RBS. Our samples show semiconductor behaviour at low bias voltages, whereas they exhibit reproducible bipolar resistance switching at higher bias voltages. The transition between both types of behaviour is observed by hysteresis in the I-V curves, indicating decomposition of the Ag(2)S, increasing the Ag(+) ion mobility. The as-fabricated Ag(2)S samples are a good candidate for future solid state memory devices, as they show reproducible memory resistive properties and they are fabricated by an accessible and reliable method.

  10. A predictive index of axillary nodal involvement in operable breast cancer.

    PubMed Central

    De Laurentiis, M.; Gallo, C.; De Placido, S.; Perrone, F.; Pettinato, G.; Petrella, G.; Carlomagno, C.; Panico, L.; Delrio, P.; Bianco, A. R.

    1996-01-01

    We investigated the association between pathological characteristics of primary breast cancer and degree of axillary nodal involvement and obtained a predictive index of the latter from the former. In 2076 cases, 17 histological features, including primary tumour and local invasion variables, were recorded. The whole sample was randomly split in a training (75% of cases) and a test sample. Simple and multiple correspondence analysis were used to select the variables to enter in a multinomial logit model to build an index predictive of the degree of nodal involvement. The response variable was axillary nodal status coded in four classes (N0, N1-3, N4-9, N > or = 10). The predictive index was then evaluated by testing goodness-of-fit and classification accuracy. Covariates significantly associated with nodal status were tumour size (P < 0.0001), tumour type (P < 0.0001), type of border (P = 0.048), multicentricity (P = 0.003), invasion of lymphatic and blood vessels (P < 0.0001) and nipple invasion (P = 0.006). Goodness-of-fit was validated by high concordance between observed and expected number of cases in each decile of predicted probability in both training and test samples. Classification accuracy analysis showed that true node-positive cases were well recognised (84.5%), but there was no clear distinction among the classes of node-positive cases. However, 10 year survival analysis showed a superimposible prognostic behaviour between predicted and observed nodal classes. Moreover, misclassified node-negative patients (i.e. those who are predicted positive) showed an outcome closer to patients with 1-3 metastatic nodes than to node-negative ones. In conclusion, the index cannot completely substitute for axillary node information, but it is a predictor of prognosis as accurate as nodal involvement and identifies a subgroup of node-negative patients with unfavourable prognosis. PMID:8630286

  11. Oak ridge national laboratory automated clean chemistry for bulk analysis of environmental swipe samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bostick, Debra A.; Hexel, Cole R.; Ticknor, Brian W.

    2016-11-01

    To shorten the lengthy and costly manual chemical purification procedures, sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment. This addresses a serious need in the nuclear safeguards community to debottleneck the separation of U and Pu in environmental samples—currently performed by overburdened chemists—with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc., the prepFAST-MC2 was designed based on current COTS equipment that was modified for U/Pu separations utilizing Eichrom™ TEVA and UTEVA resins. Initial verification of individual columns yielded small elution volumes with consistent elution profiles and good recovery. Combined columnmore » calibration demonstrated ample separation without crosscontamination of the eluent. Automated packing and unpacking of the built-in columns initially showed >15% deviation in resin loading by weight, which can lead to inconsistent separations. Optimization of the packing and unpacking methods led to a reduction in the variability of the packed resin to less than 5% daily. The reproducibility of the automated system was tested with samples containing 30 ng U and 15 pg Pu, which were separated in a series with alternating reagent blanks. These experiments showed very good washout of both the resin and the sample from the columns as evidenced by low blank values. Analysis of the major and minor isotope ratios for U and Pu provided values well within data quality limits for the International Atomic Energy Agency. Additionally, system process blanks spiked with 233U and 244Pu tracers were separated using the automated system after it was moved outside of a clean room and yielded levels equivalent to clean room blanks, confirming that the system can produce high quality results without the need for expensive clean room infrastructure. Comparison of the amount of personnel time necessary for successful manual vs. automated chemical separations showed a significant decrease in hands-on time from 9.8 hours to 35 minutes for seven samples, respectively. This documented time savings and reduced labor translates to a significant cost savings per sample. Overall, the system will enable faster sample reporting times at reduced costs by limiting personnel hours dedicated to the chemical separation.« less

  12. Training Status as a Marker of the Relationship between Nitric Oxide, Oxidative Stress, and Blood Pressure in Older Adult Women

    PubMed Central

    Mourão Jacomini, André; Celso Dutra de Souza, Hugo; da Silva Dias, Danielle; de Oliveira Brito, Janaina; Cezar Pinheiro, Lucas; Bernardino da Silva, Anderson; Fernanda da Silva, Roberta; Alexandre Trapé, Atila; De Angelis, Kátia; Tanus-Santos, José Eduardo; Lia do Amaral, Sandra; Saranz Zago, Anderson

    2016-01-01

    The purpose of this study was to evaluate the influence of functional fitness and oxidative capacity on the nitric oxide concentration associated with hemodynamic control in older adult women. The sample consisted of 134 women (65.73 ± 6.14 years old). All subjects underwent a physical examination to assess body mass index, waist-hip ratio, body fat measurement by dual energy X-ray absorptiometry, and blood pressure (BP). Training status (TS) was evaluated by indirect determination of maximal oxygen uptake by a treadmill test using Balke protocol modified for older adults. Functional fitness was also evaluated through a “Functional Fitness Battery Test” to determine the general fitness functional index (GFFI). All participants were separated according to the functional fitness (TS1, very weak and weak; TS2, regular; TS3, good and very good). Plasma blood samples were used to evaluate prooxidant and antioxidant activity and nitrite and nitrate concentrations. The general results of this study showed that good levels of TS were related to lower levels of lipoperoxidation and protein damage, higher levels of antioxidant, and higher concentration of nitrite and nitrate. This combination may be responsible for the lower levels of BP in subjects with better TS. PMID:26697141

  13. Training Status as a Marker of the Relationship between Nitric Oxide, Oxidative Stress, and Blood Pressure in Older Adult Women.

    PubMed

    Jacomini, André Mourão; de Souza, Hugo Celso Dutra; Dias, Danielle da Silva; Brito, Janaina de Oliveira; Pinheiro, Lucas Cezar; da Silva, Anderson Bernardino; da Silva, Roberta Fernanda; Trapé, Atila Alexandre; De Angelis, Kátia; Tanus-Santos, José Eduardo; do Amaral, Sandra Lia; Zago, Anderson Saranz

    2015-01-01

    The purpose of this study was to evaluate the influence of functional fitness and oxidative capacity on the nitric oxide concentration associated with hemodynamic control in older adult women. The sample consisted of 134 women (65.73 ± 6.14 years old). All subjects underwent a physical examination to assess body mass index, waist-hip ratio, body fat measurement by dual energy X-ray absorptiometry, and blood pressure (BP). Training status (TS) was evaluated by indirect determination of maximal oxygen uptake by a treadmill test using Balke protocol modified for older adults. Functional fitness was also evaluated through a "Functional Fitness Battery Test" to determine the general fitness functional index (GFFI). All participants were separated according to the functional fitness (TS1, very weak and weak; TS2, regular; TS3, good and very good). Plasma blood samples were used to evaluate prooxidant and antioxidant activity and nitrite and nitrate concentrations. The general results of this study showed that good levels of TS were related to lower levels of lipoperoxidation and protein damage, higher levels of antioxidant, and higher concentration of nitrite and nitrate. This combination may be responsible for the lower levels of BP in subjects with better TS.

  14. Evaluation of Existing Methods for Human Blood mRNA Isolation and Analysis for Large Studies

    PubMed Central

    Meyer, Anke; Paroni, Federico; Günther, Kathrin; Dharmadhikari, Gitanjali; Ahrens, Wolfgang; Kelm, Sørge; Maedler, Kathrin

    2016-01-01

    Aims Prior to implementing gene expression analyses from blood to a larger cohort study, an evaluation to set up a reliable and reproducible method is mandatory but challenging due to the specific characteristics of the samples as well as their collection methods. In this pilot study we optimized a combination of blood sampling and RNA isolation methods and present reproducible gene expression results from human blood samples. Methods The established PAXgeneTM blood collection method (Qiagen) was compared with the more recent TempusTM collection and storing system. RNA from blood samples collected by both systems was extracted on columns with the corresponding Norgen and PAX RNA extraction Kits. RNA quantity and quality was compared photometrically, with Ribogreen and by Real-Time PCR analyses of various reference genes (PPIA, β-ACTIN and TUBULIN) and exemplary of SIGLEC-7. Results Combining different sampling methods and extraction kits caused strong variations in gene expression. The use of PAXgeneTM and TempusTM collection systems resulted in RNA of good quality and quantity for the respective RNA isolation system. No large inter-donor variations could be detected for both systems. However, it was not possible to extract sufficient RNA of good quality with the PAXgeneTM RNA extraction system from samples collected by TempusTM collection tubes. Comparing only the Norgen RNA extraction methods, RNA from blood collected either by the TempusTM or PAXgeneTM collection system delivered sufficient amount and quality of RNA, but the TempusTM collection delivered higher RNA concentration compared to the PAXTM collection system. The established Pre-analytix PAXgeneTM RNA extraction system together with the PAXgeneTM blood collection system showed lowest CT-values, i.e. highest RNA concentration of good quality. Expression levels of all tested genes were stable and reproducible. Conclusions This study confirms that it is not possible to mix or change sampling or extraction strategies during the same study because of large variations of RNA yield and expression levels. PMID:27575051

  15. Effects of Partial Beef Fat Replacement with Gelled Emulsion on Functional and Quality Properties of Model System Meat Emulsions

    PubMed Central

    2016-01-01

    The objective of this study was to investigate the effects of partial beef fat replacement (0, 30, 50, 100%) with gelled emulsion (GE) prepared with olive oil on functional and quality properties of model system meat emulsion (MSME). GE consisted of inulin and gelatin as gelling agent and characteristics of gelled and model system meat emulsions were investigated. GE showed good initial stability against centrifugation forces and thermal stability at different temperatures. GE addition decreased the pH with respect to increase in GE concentration. Addition of GE increased lightness and yellowness but reduced redness compared to control samples. The results of the study showed that partial replacement of beef fat with GE could be used for improving cooking yield without negative effects on water holding capacity and emulsion stability compared to C samples when replacement level is up to 50%. The presence of GE significantly affected textural behaviors of samples (p<0.05). In conclusion, our study showed that GE have promising impacts on developing healthier meat product formulations besides improving technological characteristics. PMID:28115885

  16. Effects of Partial Beef Fat Replacement with Gelled Emulsion on Functional and Quality Properties of Model System Meat Emulsions.

    PubMed

    Serdaroğlu, Meltem; Nacak, Berker; Karabıyıkoğlu, Merve; Keser, Gökçen

    2016-01-01

    The objective of this study was to investigate the effects of partial beef fat replacement (0, 30, 50, 100%) with gelled emulsion (GE) prepared with olive oil on functional and quality properties of model system meat emulsion (MSME). GE consisted of inulin and gelatin as gelling agent and characteristics of gelled and model system meat emulsions were investigated. GE showed good initial stability against centrifugation forces and thermal stability at different temperatures. GE addition decreased the pH with respect to increase in GE concentration. Addition of GE increased lightness and yellowness but reduced redness compared to control samples. The results of the study showed that partial replacement of beef fat with GE could be used for improving cooking yield without negative effects on water holding capacity and emulsion stability compared to C samples when replacement level is up to 50%. The presence of GE significantly affected textural behaviors of samples ( p <0.05). In conclusion, our study showed that GE have promising impacts on developing healthier meat product formulations besides improving technological characteristics.

  17. Human unrestricted somatic stem cells loaded in nanofibrous PCL scaffold and their healing effect on skin defects.

    PubMed

    Bahrami, Hoda; Keshel, Saeed Heidari; Chari, Aliakbar Jafari; Biazar, Esmaeil

    2016-09-01

    Unrestricted somatic stem cells (USSCs) loaded in nanofibrous polycaprolactone (PCL) scaffolds can be used for skin regeneration when grafted onto full-thickness skin defects of rats. Nanofibrous PCL scaffolds were designed by the electrospinning method and crosslinked with laminin protein. Afterwards, the scaffolds were evaluated by scanning electron microscopy, and physical and mechanical assays. In this study, nanofibrous PCL scaffolds loaded with USSCs were grafted onto the skin defects. The wounds were subsequently investigated 21 days after grafting. Results of mechanical and physical analyses showed good resilience and compliance to movement as a skin graft. In animal models; study samples exhibited the most pronounced effect on wound closure, with statistically significant improvement in wound healing being seen at 21 days post-operatively. Histological examinations of healed wounds from all samples showed a thin epidermis plus recovered skin appendages in the dermal layer for samples with cell. Thus, the graft of nanofibrous PCL scaffolds loaded with USSC showed better results during the healing process of skin defects in rat models.

  18. [The appraisal of reliability and validity of subjective workload assessment technique and NASA-task load index].

    PubMed

    Xiao, Yuan-mei; Wang, Zhi-ming; Wang, Mian-zhen; Lan, Ya-jia

    2005-06-01

    To test the reliability and validity of two mental workload assessment scales, i.e. subjective workload assessment technique (SWAT) and NASA task load index (NASA-TLX). One thousand two hundred and sixty-eight mental workers were sampled from various kinds of occupations, such as scientific research, education, administration and medicine, etc, with randomized cluster sampling. The re-test reliability, split-half reliability, Cronbach's alpha coefficient and correlation coefficients between item score and total score were adopted to test the reliability. The test of validity included structure validity. The re-test reliability coefficients of these two scales and their items were ranged from 0.516 to 0.753 (P < 0.01), indicating the two scales had good re-test reliability; the split-half reliability of SWAT was 0.645, and its Cronbach's alpha coefficient was more than 0.80, all the correlation coefficients between its items score and total score were more than 0.70; as for NASA-TLX, both the split-half reliability and Cronbach's alpha coefficient were more than 0.80, the correlation coefficients between its items score and total score were all more than 0.60 (P < 0.01) except the item of performance. Both scales had good inner consistency. The Pearson correlation coefficient between the two scales was 0.492 (P < 0.01), implying the results of the two scales had good consistency. Factor analysis showed that the two scales had good structure validity. Both SWAT and NASA-TLX have good reliability and validity and may be used as a valid tool to assess mental workload in China after being revised properly.

  19. Development and Validation of a Measure of Maladaptive Social-Evaluative Beliefs Characteristic of Social Anxiety Disorder in Youth: The Report of Youth Social Cognitions (RYSC).

    PubMed

    Wong, Quincy J J; Certoma, Sarah P; McLellan, Lauren F; Halldorsson, Brynjar; Reyes, Natasha; Boulton, Kelsie; Hudson, Jennifer L; Rapee, Ronald M

    2017-12-28

    Recent research has started to examine the applicability of influential adult models of the maintenance of social anxiety disorder (SAD) to youth. This research is limited by the lack of psychometrically validated measures of underlying constructs that are developmentally appropriate for youth. One key construct in adult models of SAD is maladaptive social-evaluative beliefs. The current study aimed to develop and validate a measure of these beliefs in youth, known as the Report of Youth Social Cognitions (RYSC). The RYSC was developed with a clinical sample of youth with anxiety disorders (N = 180) and cross-validated in a community sample of youth (N = 305). In the clinical sample, the RYSC exhibited a 3-factor structure (negative evaluation, revealing self, and positive impression factors), good internal consistency, and construct validity. In the community sample, the 3-factor structure and the internal consistency of the RYSC were replicated, but the test of construct validity showed that the RYSC had similarly strong associations with social anxiety and depressed affect. The RYSC had good test-retest reliability overall, although the revealing self subscale showed lower temporal stability which improved when only older participants were considered (age ≥9 years). The RYSC in general was also shown to discriminate between youth with and without SAD although the revealing self subscale again performed suboptimally but improved when only older participants were considered. These findings provide psychometric support for the RYSC and justifies its use with youth in research and clinical settings requiring the assessment of maladaptive social-evaluative beliefs. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  20. Characterization of Italian honeys (Marche Region) on the basis of their mineral content and some typical quality parameters

    PubMed Central

    Conti, Marcelo Enrique; Stripeikis, Jorge; Campanella, Luigi; Cucina, Domenico; Tudino, Mabel Beatriz

    2007-01-01

    Background The characterization of three types of Marche (Italy) honeys (Acacia, Multifloral, Honeydew) was carried out on the basis of the their quality parameters (pH, sugar content, humidity) and mineral content (Na, K, Ca, Mg, Cu, Fe, and Mn). Pattern recognition methods such as principal components analysis (PCA) and linear discriminant analysis (LDA) were performed in order to classify honey samples whose botanical origins were different, and identify the most discriminant parameters. Lastly, using ANOVA and correlations for all parameters, significant differences between diverse types of honey were examined. Results Most of the samples' water content showed good maturity (98%) whilst pH values were in the range 3.50 – 4.21 confirming the good quality of the honeys analysed. Potassium was quantitatively the most relevant mineral (mean = 643 ppm), accounting for 79% of the total mineral content. The Ca, Na and Mg contents account for 14, 3 and 3% of the total mineral content respectively, while other minerals (Cu, Mn, Fe) were present at very low levels. PCA explained 75% or more of the variance with the first two PC variables. The variables with higher discrimination power according to the multivariate statistical procedure were Mg and pH. On the other hand, all samples of acacia and honeydew, and more than 90% of samples of multifloral type have been correctly classified using the LDA. ANOVA shows significant differences between diverse floral origins for all variables except sugar, moisture and Fe. Conclusion In general, the analytical results obtained for the Marche honeys indicate the products' high quality. The determination of physicochemical parameters and mineral content in combination with modern statistical techniques can be a useful tool for honey classification. PMID:17880749

  1. Use of Passive Diffusion Samplers for Monitoring Volatile Organic Compounds in Ground Water

    USGS Publications Warehouse

    Harte, Philip T.; Brayton, Michael J.; Ives, Wayne

    2000-01-01

    Passive diffusion samplers have been tested at a number of sites where volatile organic compounds (VOC's) are the principal contaminants in ground water. Test results generally show good agreement between concentrations of VOC's in samples collected with diffusion samplers and concentrations in samples collected by purging the water from a well. Diffusion samplers offer several advantages over conventional and low-flow ground-water sampling procedures: * Elimination of the need to purge a well before collecting a sample and to dispose of contaminated water. * Elimination of cross-contamination of samples associated with sampling with non-dedicated pumps or sample delivery tubes. * Reduction in sampling time by as much as 80 percent of that required for 'purge type' sampling methods. * An increase in the frequency and spatial coverage of monitoring at a site because of the associated savings in time and money. The successful use of diffusion samplers depends on the following three primary factors: (1) understanding site conditions and contaminants of interest (defining sample objectives), (2) validating of results of diffusion samplers against more widely acknowledged sampling methods, and (3) applying diffusion samplers in the field.

  2. USGS GeoData Digital Raster Graphics

    USGS Publications Warehouse

    ,

    2001-01-01

    Passive diffusion samplers have been tested at a number of sites where volatile organic compounds (VOC?s) are the principal contaminants in ground water. Test results generally show good agreement between concentrations of VOC?s in samples collected with diffusion samplers and concentrations in samples collected by purging the water from a well. Diffusion samplers offer several advantages over conventional and low-flow ground-water sampling procedures: ? Elimination of the need to purge a well before collecting a sample and to dispose of contaminated water. ? Elimination of cross-contamination of samples associated with sampling with non-dedicated pumps or sample delivery tubes. ? Reduction in sampling time by as much as 80 percent of that required for ?purge type? sampling methods. ? An increase in the frequency and spatial coverage of monitoring at a site because of the associated savings in time and money. The successful use of diffusion samplers depends on the following three primary factors: (1) understanding site conditions and contaminants of interest (defining sample objectives), (2) validating of results of diffusion samplers against more widely acknowledged sampling methods, and (3) applying diffusion samplers in the field.

  3. Role of aging time on the magnetic properties of Sm2Co17 permanent magnets processed through cold isostatic pressing

    NASA Astrophysics Data System (ADS)

    Ramudu, M.; Rajkumar, D. M.

    2018-04-01

    The effect of aging time on the magnetic properties of Sm2Co17 permanent magnets processed through a novel method of cold isostatic pressing was investigated. Sintered Sm2Co17 samples were subjected to different aging times in the range of 10-30 h and their respective microstructures were correlated with the magnetic properties obtained. The values of remanant magnetization (Br) were observed to be constant in samples aged from 10-20 h beyond which a gradual decrease in Br values was observed. The values of coercivity (Hc) displayed a sharp increase in samples aged from 10 to 20 h beyond which the coercivity values showed marginal improvement. Hence a good combination of magnetic properties could be achieved in samples aged for 20 h. A maximum energy product of 27 MGOe was achieved in the 20 h aged sample processed through a novel route.

  4. Determination of an effective sampling regime to detect salmonella enteritidis in the environment of poultry units.

    PubMed

    Davies, R H; Wray, C

    1996-05-01

    A study of the dissemination of Salmonella enteritidis in the poultry breeder industry in the UK showed that the choice of sites for sampling the environment of occupied houses and empty houses which had been disinfected after depopulation had a significant influence on the outcome. Increased isolation rates could be achieved by sampling nest box floors and dust in open slave feed hoppers in occupied poultry houses. Nest box floors were the most sensitive sites for detection of residual environmental contamination in poultry houses where enrofloxacin treatment had been used. Floor sweepings, nest box floors, slave feed hoppers, hydrated wall fabric junctions and high beams and pipes were the most sensitive sample sites in cleansed and disinfected poultry houses. The use of universal disinfectant neutralisers gave good results in laboratory trials but appeared to reduce the isolation rate from field samples.

  5. Determination of free formaldehyde in cosmetics containing formaldehyde-releasing preservatives by reversed-phase dispersive liquid-liquid microextraction and liquid chromatography with post-column derivatization.

    PubMed

    Miralles, Pablo; Chisvert, Alberto; Alonso, M José; Hernandorena, Sandra; Salvador, Amparo

    2018-03-30

    An analytical method for the determination of traces of formaldehyde in cosmetic products containing formaldehyde-releasing preservatives has been developed. The method is based on reversed-phase dispersive liquid-liquid microextraction (RP-DLLME), that allows the extraction of highly polar compounds, followed by liquid chromatography-ultraviolet/visible (LC-UV/vis) determination with post-column derivatization. The variables involved in the RP-DLLME process were studied to provide the best enrichment factors. Under the selected conditions, a mixture of 500 μL of acetonitrile (disperser solvent) and 50 μL of water (extraction solvent) was rapidly injected into 5 mL of toluene sample solution. The extracts were injected into the LC-UV/vis system using phosphate buffer 6 mmol L -1 at pH 2 as mobile phase. After chromatographic separation, the eluate merged with a flow stream of pentane-2,4-dione in ammonium acetate solution as derivatizing reagent and passed throughout a post-column reactor at 85 °C in order to derivatize formaldehyde into 3,5-diacetyl-1,4-dihydrolutidine, according to Hantzsch reaction, which was finally measured spectrophotometrically at 407 nm. The method was successfully validated showing good linearity, an enrichment factor of 86 ± 2, limits of detection and quantification of 0.7 and 2.3 ng mL -1 , respectively, and good repeatability (RSD < 9.2%). Finally, the proposed analytical method was applied to the determination of formaldehyde in different commercial cosmetic samples containing formaldehyde-releasing preservatives, such as bronopol, diazolidinyl urea, imidazolidinyl urea, and DMDM hydantoin, with good relative recovery values (91-113%) thus showing that matrix effects were negligible. The good analytical features of the proposed method besides of its simplicity and affordability, make it useful to carry out the quality control of cosmetic products containing formaldehyde-releasing preservatives. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Ir and Rare Earth's Elements determination by Neutron Activation Analysis and ICP - MS in soil samples

    NASA Astrophysics Data System (ADS)

    Salvini, A.; Cattadori, C.; Broggini, C.; Cagnazzo, M.; Ori, Gian Gabriele; Nisi, S.; Borio, A.; Manera, S.

    2006-05-01

    The platinum metals depleted in the earth's crust are relative to their cosmic abundance; concentration of these elements in sediments may thus indicate influxes of extraterrestrial material. Analysis of these parameters are done easily by Neutron Activation Analysis (NAA) and comparative results with ICP-MS technique show a good match. Results, adjust parameters and limits of this method will be displayed in tables.

  7. Geology and ground-water resources of Nobles County, and part of Jackson County, Minnesota

    USGS Publications Warehouse

    Norvitch, Ralph F.

    1964-01-01

    The quality of water in the Precambrian crystalline rocks, the Cretaceous strata, and the buried Pleistocene aquifers is poor. Chemical analyses of 22 water samples showed that dissolved solids ranged from 1,100 ppm (parts per million) to 3,050 ppm. Water from the surficial outwash deposits is good by comparison; dissolved solids in water from these aquifers ranged from 425 to 870 ppm.

  8. Determination of phenol compounds in surface water matrices by bar adsorptive microextraction-high performance liquid chromatography-diode array detection.

    PubMed

    Neng, Nuno R; Nogueira, José M F

    2014-07-03

    Bar adsorptive microextraction combined with liquid desorption followed by high performance liquid chromatography with diode array detection (BAµE-LD/HPLC-DAD) is proposed for the determination of trace levels of five phenol compounds (3-nitrophenol, 4-nitrophenol, bisphenol-A, 4-n-octylphenol and 4-n-nonylphenol) in surface water matrices. By using a polystyrene-divinylbenzene copolymer (PS-DVB) sorbent phase, high selectivity and efficiency is achieved even against polydimethylsiloxane through stir bar sorptive extraction. Assays performed by BAµE(PS-DVB)-LD/HPLC-DAD on 25 mL water samples spiked at the 10.0 µg/L levels yielded recoveries over 88.0%±5.7% for all five analytes, under optimized experimental conditions. The analytical performance showed good precision (RSD<15%), detection limits of 0.25 µg/L and linear dynamic ranges (1.0-25.0 μg/L) with determination coefficient higher than 0.9904. By using the standard addition method, the application of the present method to surface water matrices allowed very good performances at the trace level. The proposed methodology proved to be a suitable alternative to monitor phenol compounds in surface water matrices, showing to be easy to implement, reliable, sensitive and requiring a low sample volume.

  9. Development and Validation of a Questionnaire on Breastfeeding Intentions, Attitudes and Knowledge of a Sample of Croatian Secondary-School Students.

    PubMed

    Čatipović, Marija; Marković, Martina; Grgurić, Josip

    2018-04-27

    Validating a questionnaire/instrument before proceeding to the field for data collection is important. An 18-item breastfeeding intention, 39-item attitude and 44-item knowledge questionnaire was validated in a Croatian sample of secondary-school students ( N = 277). For the intentions, principal component analysis (PCA) yielded a four-factor solution with 8 items explaining 68.3% of the total variance. Cronbach’s alpha (0.71) indicated satisfactory internal consistency. For the attitudes, PCA showed a seven-factor structure with 33 items explaining 58.41% of total variance. Cronbach’s alpha (0.87) indicated good internal consistency. There were 13 knowledge questions that were retained after item analysis, showing good internal consistency (KR20 = 0.83). In terms of criterion validity, the questionnaire differentiated between students who received breastfeeding education compared to students who were not educated in breastfeeding. Correlations between intentions and attitudes (r = 0.49), intentions and knowledge (r = 0.29), and attitudes and knowledge (r = 0.38) confirmed concurrent validity. The final instrument is reliable and valid for data collection on breastfeeding. Therefore, the instrument is recommended for evaluation of breastfeeding education programs aimed at upper-grade elementary and secondary school students.

  10. Development and Validation of a Questionnaire on Breastfeeding Intentions, Attitudes and Knowledge of a Sample of Croatian Secondary-School Students

    PubMed Central

    Marković, Martina; Grgurić, Josip

    2018-01-01

    Background: Validating a questionnaire/instrument before proceeding to the field for data collection is important. Methods: An 18-item breastfeeding intention, 39-item attitude and 44-item knowledge questionnaire was validated in a Croatian sample of secondary-school students (N = 277). Results: For the intentions, principal component analysis (PCA) yielded a four-factor solution with 8 items explaining 68.3% of the total variance. Cronbach’s alpha (0.71) indicated satisfactory internal consistency. For the attitudes, PCA showed a seven-factor structure with 33 items explaining 58.41% of total variance. Cronbach’s alpha (0.87) indicated good internal consistency. There were 13 knowledge questions that were retained after item analysis, showing good internal consistency (KR20 = 0.83). In terms of criterion validity, the questionnaire differentiated between students who received breastfeeding education compared to students who were not educated in breastfeeding. Correlations between intentions and attitudes (r = 0.49), intentions and knowledge (r = 0.29), and attitudes and knowledge (r = 0.38) confirmed concurrent validity. Conclusions: The final instrument is reliable and valid for data collection on breastfeeding. Therefore, the instrument is recommended for evaluation of breastfeeding education programs aimed at upper-grade elementary and secondary school students. PMID:29702616

  11. Combining bar adsorptive microextraction with capillary electrophoresis--application for the determination of phenolic acids in food matrices.

    PubMed

    da Rosa Neng, Nuno; Sequeiros, Rute C P; Florêncio Nogueira, José Manuel

    2014-09-01

    In this contribution, bar adsorptive microextraction coated with a mixed-mode anion exchange/RP followed by liquid desorption was combined for the first time with a capillary electrophoresis-diode array detection system (BAμE(MAX)-LD/CE-DAD), for the determination of phenolic acids in food matrices, using chlorogenic, ferulic, cumaric, and caffeic acids as model compounds. Assays performed in aqueous media spiked at the 0.8 mg/L level yielded average recoveries up to 40% for all four phenolic acids, under optimized experimental conditions. The analytical performance showed also good precision (RSD < 15%), convenient LODs (18.0-85.0 μg/L) and linear dynamic ranges (0.8-8.0 mg/L) with convenient determination coefficients (r(2) > 0.9900). By using the standard addition method, the application to food matrices such as green tea, red fruit juice, and honey allowed very good performances for the determination of minor amounts of phenolic acids. The proposed methodology proved to be a suitable alternative for the analysis of polar to ionic compounds, showing to be easy to implement, reliable, sensitive, and requiring a low sample volume to determine phenolic acids in food samples. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Public preception on education partnership programs between Indonesia and australia in East Nusa Tenggara Province

    NASA Astrophysics Data System (ADS)

    Lobo, M.; Guntur, R. D.; Nalley, H. M.

    2018-05-01

    A research about partnership program in education between the government of Indonesia and Australia in East Nusa Tenggara Province (ENTP) has been conducted. The aim is to list the programs between the countries on the region in the last twenty years, together with their implementations to the community based on all the stakeholders’ perspectives. The samples taken by purposive sampling which targeted those who had direct involvement to the programs in the Districts of Sikka, Ende and Ngada. A literature review, questioners and a depth interview were employed in the data collection. The results show that the main partnership projects were NTT-PEP (Nusa Tenggara Timur-Primary Education Partnership), AIBEP (Australia Indonesia Building Education Project) and ProDEP (Professional Development for Education Personal). While the first and the third programs were targeting on human resources development, the second project was more focusing on the infrastructures. The analysis shows that in general, the majority of people think that the program implementation was good. Similar results were also reflected in the group of superintendent and the community. However, totally different feature was found in the group of government officials where all of them perceived that the program was good and need to be continued and sustained.

  13. Determination of sixteen elements and arsenic species in brown, polished and milled rice.

    PubMed

    Narukawa, Tomohiro; Matsumoto, Eri; Nishimura, Tsutomu; Hioki, Akiharu

    2014-01-01

    The concentrations of 16 elements in 10 rice flour samples and the distribution of the elements in the rice grains from which the flour were made were determined by ICP-MS and ICP-OES after microwave-assisted digestion of the samples. Arsenic speciation analysis was carried out by HPLC-ICP-MS following heat-assisted extraction of the sample. The concentrations of inorganic As (As(III) and As(V)), monomethylarsonic acid (MMAA) and dimethylarsinic acid (DMAA) and their distribution in the rice grains were determined. Portions of the brown rice were polished/milled to different degrees to yield milled off samples and polished rice samples. All samples were powdered and analyzed for 16 elements and for As species. The recoveries and mass balances for all elements in all samples showed good agreements with the starting materials. As(III), As(V), MMAA and DMAA were detected, and the sums of the concentrations of all species in the extract were 86-105% of the total As concentration in each case.

  14. [Determination of 27 elements in Maca nationality's medicine by microwave digestion ICP-MS].

    PubMed

    Yu, Gui-fang; Zhong, Hai-jie; Hu, Jun-hua; Wang, Jing; Huang, Wen-zhe; Wang, Zhen-zhong; Xiao, Wei

    2015-12-01

    An analysis method has been established to test 27 elements (Li, Be, B, Mg, Al, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, As, Sr, Mo, Cd, Sn, Sb, Ba, La, Hg, Pb, Bi) in Maca nationality's medicine with microwave digestion-ICP-MS. Sample solutions were analyzed by ICP-MS after microwave digestion, and the contents of elements were calculated according to their calibration curves, and internal standard method was adopted to reduce matrix effect and other interference effects. The experimental results showed that the linear relations of all the elements were very good; the correlation coefficient (r) was 0.9994-1.0000 (Hg was 0.9982) ; the limits of detection were 0.003-2.662 microg x L(-1); the relative standard deviations for all elements of reproducibility were lower than 5% (except the individual elements); the recovery rate were 78.5%-123.7% with RSD lower than 5% ( except the individual elements). The analytical results of standard material showed acceptable agreement with the certified values. This method was applicable to determinate the contents of multi-elements in Maca which had a high sensitivity, good specificity and good repeatability, and provide basis for the quality control of Maca.

  15. A ratiometric strategy -based electrochemical sensing interface for the sensitive and reliable detection of imidacloprid.

    PubMed

    Li, Xueyan; Kan, Xianwen

    2018-04-30

    In this study, a ratiometric strategy-based electrochemical sensor was developed by electropolymerization of thionine (THI) and β-cyclodextrin (β-CD) composite films on a glassy carbon electrode surface for imidacloprid (IMI) detection. THI played the role of an inner reference element to provide a built-in correction. In addition, the modified β-CD showed good selective enrichment for IMI to improve the sensitivity and anti-interference ability of the sensor. The current ratio between IMI and THI was calculated as the detected signal for IMI sensing. Compared with common single-signal sensing, the proposed ratiometric strategy showed a higher linear range and a lower limit of detection of 4.0 × 10-8-1.0 × 10-5 mol L-1 and 1.7 × 10-8 mol L-1, respectively, for IMI detection. On the other hand, the ratiometric strategy endowed the sensor with good accuracy, reproducibility, and stability. The sensor was also used for IMI determination in real samples with satisfactory results. The simple, effective, and reliable way reported in this study can be further used to prepare ratiometric strategy-based electrochemical sensors for the selective and sensitive detection of other compounds with good accuracy and stability.

  16. Validation of the Brazilian version of the 'Spanish Burnout Inventory' in teachers.

    PubMed

    Gil-Monte, Pedro R; Carlotto, Mary Sandra; Câmara, Sheila Gonçalves

    2010-02-01

    To assess factorial validity and internal consistency of the Brazilian version of the 'Spanish Burnout Inventory' (SBI). The translation process of the SBI into Brazilian Portuguese included translation, back translation, and semantic equivalence. A confirmatory factor analysis was carried out using a four-factor model, which was similar to the original SBI. The sample consisted of 714 teachers working in schools in the metropolitan area of the city of Porto Alegre, Southern Brazil, in 2008. The instrument comprises 20 items and four subscales: Enthusiasm towards job (5 items), Psychological exhaustion (4 items), Indolence (6 items), and Guilt (5 items). The model was analyzed using LISREL 8. Goodness-of-Fit statistics showed that the hypothesized model had adequate fit: chi2(164) = 605.86 (p<0.000); Goodness-of-Fit Index = 0.92; Adjusted Goodness-of-Fit Index = 0.90; Root Mean Square Error of Approximation = 0.062; Nonnormed Fit Index = 0.91; Comparative Fit Index = 0.92; and Parsimony Normed Fit Index = 0.77. Cronbach's alpha measures for all subscales were higher than 0.70. The study showed that the SBI has adequate factorial validity and internal consistency to assess burnout in Brazilian teachers.

  17. Thermal effect on structural and magnetic properties of Fe78B13Si9 annealed amorphous ribbons

    NASA Astrophysics Data System (ADS)

    Soltani, Mohamed Larbi; Touares, Abdelhay; Aboki, Tiburce A. M.; Gasser, Jean-Georges

    2017-08-01

    In the present work, we study the influence of thermal treatments on the magnetic properties of as-quenched and pre-crystallized Fe78Si9B13 after stress relaxation. The crystallization behavior of amorphous and treated Fe78Si9B13 ribbons was revisited. The measurements were carried out by means of Differential Scanning Calorimetry, by X-ray diffraction and by Vibrating Sample Magnetometer, Susceptometer and fluxmeter. Relaxed samples were heated in the resistivity device up to 700°C and annealed near the onset temperature about 420°C for respectively 1, 3, 5, 8 hours. In as-quenched samples, two transition points occur at about 505°C and 564°C but in relaxed sample, the transition points have been found about 552°C and 568°C. Kinetics of crystallization was deduced for all studied samples. Annealing of the as-purchased ribbon shows the occurrence of α-Fe and tetragonal Fe3B resulting from the crystallization of the remaining amorphous phase. The effects on magnetic properties were pointed out by relating the structural evolution of the samples. The magnetic measurements show that annealing change the saturation magnetization and the coercive magnetic field values, hence destroying the good magnetic properties of the material. The heat treatment shows that the crystallization has greatly altered the shape of the cycles and moved the magnetic saturation point of the samples. The effect of treatment on the magneto-crystalline anisotropy is also demonstrated.

  18. How Good Are Statistical Models at Approximating Complex Fitness Landscapes?

    PubMed Central

    du Plessis, Louis; Leventhal, Gabriel E.; Bonhoeffer, Sebastian

    2016-01-01

    Fitness landscapes determine the course of adaptation by constraining and shaping evolutionary trajectories. Knowledge of the structure of a fitness landscape can thus predict evolutionary outcomes. Empirical fitness landscapes, however, have so far only offered limited insight into real-world questions, as the high dimensionality of sequence spaces makes it impossible to exhaustively measure the fitness of all variants of biologically meaningful sequences. We must therefore revert to statistical descriptions of fitness landscapes that are based on a sparse sample of fitness measurements. It remains unclear, however, how much data are required for such statistical descriptions to be useful. Here, we assess the ability of regression models accounting for single and pairwise mutations to correctly approximate a complex quasi-empirical fitness landscape. We compare approximations based on various sampling regimes of an RNA landscape and find that the sampling regime strongly influences the quality of the regression. On the one hand it is generally impossible to generate sufficient samples to achieve a good approximation of the complete fitness landscape, and on the other hand systematic sampling schemes can only provide a good description of the immediate neighborhood of a sequence of interest. Nevertheless, we obtain a remarkably good and unbiased fit to the local landscape when using sequences from a population that has evolved under strong selection. Thus, current statistical methods can provide a good approximation to the landscape of naturally evolving populations. PMID:27189564

  19. Rapidly Mixing Gibbs Sampling for a Class of Factor Graphs Using Hierarchy Width

    PubMed Central

    De Sa, Christopher; Zhang, Ce; Olukotun, Kunle; Ré, Christopher

    2016-01-01

    Gibbs sampling on factor graphs is a widely used inference technique, which often produces good empirical results. Theoretical guarantees for its performance are weak: even for tree structured graphs, the mixing time of Gibbs may be exponential in the number of variables. To help understand the behavior of Gibbs sampling, we introduce a new (hyper)graph property, called hierarchy width. We show that under suitable conditions on the weights, bounded hierarchy width ensures polynomial mixing time. Our study of hierarchy width is in part motivated by a class of factor graph templates, hierarchical templates, which have bounded hierarchy width—regardless of the data used to instantiate them. We demonstrate a rich application from natural language processing in which Gibbs sampling provably mixes rapidly and achieves accuracy that exceeds human volunteers. PMID:27279724

  20. Determination of the content of alkyl ketene dimer in its latex by an ionic-liquid assisted headspace gas chromatography.

    PubMed

    Yan, Ning; Wan, Xiao-Fang; Chai, Xin-Sheng; Chen, Run-Quan; Chen, Chun-Xia

    2017-12-29

    This paper reports on an ionic-liquid assisted headspace gas chromatographic (HS-GC) for the determination of the content of alkyl ketene dimer (AKD) in its latex samples, in which the GC system was equipped with a thermal conductivity detector (TCD). The method was based on the AKD hydrolysis conducted in 1-butyl-3-methylimidazolium chloride (ionic-liquid) added medium at 100°C for 10min in a closed headspace sample vial, and the measured CO 2 (the resulting product of the hydrolysis) by HS-GC. The results showed that the present method has a good measurement precision (RSD <2.3%) and accuracy (recoveries from 96 - 105%), and the limit of quantitation (LOQ) is 0.9%. The present method is very suitable to be used for the routine check of AKD content in its latex sample in mill applications. The study also showed that the content of AKD in the tested commercial latex samples were in the range of 3.5-12%. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Physical-durable performance of concrete incorporating high loss on ignition-fly ash

    NASA Astrophysics Data System (ADS)

    Huynh, Trong-Phuoc; Ngo, Si-Huy; Hwang, Chao-Lung

    2018-04-01

    This study investigates the feasibility of using raw fly ash with a high loss on ignition in concrete. The fly ash-free concrete samples were prepared with different water-to-binder (w/b) ratios of 0.35, 0.40, and 0.45, whereas the fly ash concrete samples were prepared with a constant w/b of 0.40 and with various fly ash contents (10%, 20%, and 30%) as a cement substitution. The physical properties and durability performance of the concretes were evaluated through fresh concrete properties, compressive strength, strength efficiency of cement, ultrasonic pulse velocity, and resistance to sulfate attack. Test results show that the w/b ratio affected the concrete properties significantly. The incorporation of fly ash increased the workability and reduced the unit weight of fresh concrete. In addition, the fly ash concrete samples containing up to 20% fly ash exhibited an improved strength at long-term ages. Further, all of the fly ash concrete samples showed a good durability performance with ultrasonic pulse velocity value of greater than 4100 m/s and a comparable sulfate resistance to the no-fly ash concrete.

  2. "Reactive" optical sensor for Hg2+ and its application in environmental aqueous media and biological systems.

    PubMed

    Chen, Zhi; Chen, Jiayun; Pan, Dong; Li, Hongwei; Yao, Yunhui; Lyu, Zu; Yang, Liting; Ma, Li-Jun

    2017-03-01

    A new rhodamine B-based "reactive" optical sensor (1) for Hg 2+ was synthesized. Sensor 1 shows a unique colorimetric and fluorescent "turn-on" selectivity to Hg 2+ over 14 other metal ions with a hypersensitivity (detection limits are 27.6 nM (5.5 ppb) and 6.9 nM (1.4 ppb), respectively) in neutral buffer solution. To test its applicability in the environment, sensor 1 was applied to quantify and visualize low levels of Hg 2+ in tap water and river water samples. The results indicate sensor 1 is a highly sensitive fluorescent sensor for Hg 2+ with a detection limit of 1.7 ppb in tap water and river water. Moreover, sensor 1 is a convenient visualizing sensor for low levels of Hg 2+ (0.1 ppm) in water environment (from colorless to light pink). In addition, sensor 1 shows good potential as a fluorescent visualizing sensor for Hg 2+ in fetal bovine serum and living 293T cells. The results indicate that sensor 1 shows good potential as a highly sensitive sensor for the detection of Hg 2+ in environmental and biological samples. Graphical Abstract A new rhodamine B-based "reactive" optical sensor (1) for Hg 2+ was synthesized. 1 shows a unique colorimetric and fluorescent "turn-on" selectivity to Hg 2+ over 14 other metal ions with a hypersensitivity in water environment. And it is a convenient visualizing probe for low levels of Hg 2+ in environment aqueous media, fetal bovine serum and living 293T cells.

  3. Phosphatase activity in Antarctica soil samples as a biosignature of extant life

    NASA Astrophysics Data System (ADS)

    Sato, Shuji; Itoh, Yuki; Takano, Yoshinori; Fukui, Manabu; Kaneko, Takeo; Kobayashi, Kensei

    Microbial activities have been detected in such extreme terrestrial environments as deep lithosphere, a submarine hydrothermal systems, stratosphere, and Antarctica. Microorganisms have adapted to such harsh environments by evolving their biomolecules. Some of these biomolecules such as enzymes might have different characteristics from those of organisms in ordinary environments. Many biosignatures (or biomarkers) have been proposed to detect microbial activities in such extreme environments. A number of techniques are proposed to evaluate biological activities in extreme environments including cultivation methods, assay of metabolism, and analysis of bioorganic compounds like amino acids and DNA. Enzyme activities are useful signature of extant life in extreme environments. Among many enzymes, phosphatase could be a good indicator of biological activities, since phosphate esters are essential for all the living terrestrial organisms. In addition, alkaline phosphatase is known as a typical zinc-containing metalloenzyme and quite stable in environments. We analyzed phosphatase activities in Antarctica soil samples to see whether they can be used as biosignatures for extant life. In addition, we characterized phosphatases extracted from the Antarctica soil samples, and compared with those obtained from other types of environments. Antarctica surface environments are quite severe environments for life since it is extremely cold and dry and exposed to strong UV and cosmic rays. We tried to evaluate biological activities in Antarctica by measuring phosphatase activities. Surface soil samples are obtained at the Sites 1-8 near Showa Base in Antarctica during the 47th Japan Antarctic exploration mission in 2005-6. Activities of acid phosphatase (ACP) and alkaline phosphatase (ALP) are measured spectrophotometrically after mixing the powdered sample and p-nitrophenyl phosphate solution (pH 6.5 for ACP, pH 8.0 for ALP). ALP was characterized after extraction from soils with Tris-HCl buffer (pH 9.0), where the activity was measured fluorometrically with 4-methylumbelliferyl phosphate (pH 8.0) as a substance. The soil of Site 8 (near a penguin rookery) showed almost the same level of ACP and ALP activities as usual surface soil sampled in YNU campus, while the soil of Sites 1-7 showed much less activities. ALP in the extract from the soil of Site 8 was characterized. It showed the maximal at 338 K, while ALP from the campus soil showed the maximal at 358 K. Gel filtration chromatography showed that the ALP activity was found only in the fraction whose molecular weights were over 60000. The ALP activity was diminished with EDTA and was recovered with addition of zinc ion. The present results showed that zinc-containing metalloenzymes, which had lower optimum temperature than those in usual environments, are present in Antarctica soil. It was suggested that phosphatases are good bio-signatures for extant life in extreme environments.

  4. Enterobacteriaceae Antibiotic Resistance in Ready-to-Eat Foods Collected from Hospital and Community Canteens: Analysis of Prevalence.

    PubMed

    Vincenti, Sara; Raponi, Matteo; Sezzatini, Romina; Giubbini, Gabriele; Laurenti, Patrizia

    2018-03-01

    Foodborne diseases and antibiotic resistance are serious widespread health problems in the contemporary world. In this study, we compared the microbiological quality of ready-to-eat (RTE) foods found in community canteens versus hospital canteens in Rome, Italy, focusing on detection and quantification of Enterobacteriaceae and the antibiotic resistance of these bacteria. Our findings show a remarkable difference in Enterobacteriaceae contamination between RTE foods distributed in community canteens (33.5% of samples) and those distributed in hospital canteens (5.3% of samples). This result highlights greater attention to good manufacturing practices and good hygiene practices by the food operators in hospitals compared with food operators in community canteens. As expected, a higher percentage of cold food samples (70.9%) than of hot food samples (10.8%) were positive for these bacteria. Excluding the intrinsic resistance of each bacterial strain, 92.3% of the isolated strains were resistant to at least one antibiotic, and about half of the isolated strains were classified as multidrug resistant. The prevalence of multidrug-resistant strains was 50% in the community samples and 33.3% in hospital canteens. Our results indicate that approximately 38% of RTE foods provided in community canteens is not compliant with microbiological food safety criteria and could be a special risk for consumers through spread of antibiotic-resistant strains. Hygienic processing and handling of foods is necessary for both hospital and community canteens.

  5. New Empirical Evidence on the Validity and the Reliability of the Early Life Stress Questionnaire in a Polish Sample.

    PubMed

    Sokołowski, Andrzej; Dragan, Wojciech Ł

    2017-01-01

    Background: The Early Life Stress Questionnaire (ELSQ) is widely used to estimate the prevalence of negative events during childhood, including emotional, physical, verbal, sexual abuse, negligence, severe conflicts, separation, parental divorce, substance abuse, poverty, and so forth. Objective: This study presents the psychometric properties of the Polish adaptation of the ELSQ. It also verifies if early life stress (ELS) is a good predictor of psychopathology symptoms during adulthood. Materials and Methods: We analyzed data from two samples. Sample 1 was selected by random quota method from across the country and included 609 participants aged 18-50 years, 306 women (50.2%) and 303 men (49.8%). Sample 2 contained 503 young adults (253 women and 250 men) aged 18-25. Confirmatory and exploratory factor analyses were used to measure ELSQ internal consistency. The validity was based on the relation to psychopathological symptoms and substance misuse. Results: Results showed good internal consistency and validity. Exploratory factor analysis indicates a six-factor structure of the ELSQ. ELS was related to psychopathology in adulthood, including depressive, sociophobic, vegetative as well as pain symptoms. ELSQ score correlated also with alcohol use, but not nicotine dependence. Moreover, ELS was correlated with stress in adulthood. Conclusion: The findings indicate that the Polish version of the ELSQ is a valid and reliable instrument for assessing ELS in the Polish population and may be applied in both clinical and community samples.

  6. Ionic liquid-impregnated agarose film two-phase micro-electrodriven membrane extraction (IL-AF-μ-EME) for the analysis of antidepressants in water samples.

    PubMed

    Mohamad Hanapi, Nor Suhaila; Sanagi, Mohd Marsin; Ismail, Abd Khamim; Wan Ibrahim, Wan Aini; Saim, Nor'ashikin; Wan Ibrahim, Wan Nazihah

    2017-03-01

    The aim of this study was to investigate and apply supported ionic liquid membrane (SILM) in two-phase micro-electrodriven membrane extraction combined with high performance liquid chromatography-ultraviolet detection (HPLC-UV) for pre-concentration and determination of three selected antidepressant drugs in water samples. A thin agarose film impregnated with 1-hexyl-3-methylimidazolium hexafluorophosphate, [C 6 MIM] [PF 6 ], was prepared and used as supported ionic liquid membrane between aqueous sample solution and acceptor phase for extraction of imipramine, amitriptyline and chlorpromazine. Under the optimized extraction conditions, the method provided good linearity in the range of 1.0-1000μgL -1 , good coefficients of determination (r 2 =0.9974-0.9992) and low limits of detection (0.1-0.4μgL -1 ). The method showed high enrichment factors in the range of 110-150 and high relative recoveries in the range of 88.2-111.4% and 90.9-107.0%, for river water and tap water samples, respectively with RSDs of ≤7.6 (n=3). This method was successfully applied to the determination of the drugs in river and tap water samples. It is envisaged that the SILM improved the perm-selectivity by providing a pathway for targeted analytes which resulted in rapid extraction with high degree of selectivity and high enrichment factor. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Rapid Analysis of Carbohydrates in Bioprocess Samples: An Evaluation of the CarboPac SA10 for HPAE-PAD Analysis by Interlaboratory Comparison

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sevcik, R. S.; Hyman, D. A.; Basumallich, L.

    2013-01-01

    A technique for carbohydrate analysis for bioprocess samples has been developed, providing reduced analysis time compared to current practice in the biofuels R&D community. The Thermofisher CarboPac SA10 anion-exchange column enables isocratic separation of monosaccharides, sucrose and cellobiose in approximately 7 minutes. Additionally, use of a low-volume (0.2 mL) injection valve in combination with a high-volume detection cell minimizes the extent of sample dilution required to bring sugar concentrations into the linear range of the pulsed amperometric detector (PAD). Three laboratories, representing academia, industry, and government, participated in an interlaboratory study which analyzed twenty-one opportunistic samples representing biomass pretreatment, enzymaticmore » saccharification, and fermentation samples. The technique's robustness, linearity, and interlaboratory reproducibility were evaluated and showed excellent-to-acceptable characteristics. Additionally, quantitation by the CarboPac SA10/PAD was compared with the current practice method utilizing a HPX-87P/RID. While these two methods showed good agreement a statistical comparison found significant quantitation difference between them, highlighting the difference between selective and universal detection modes.« less

  8. Structural, Morphological, Differential Scanning Calorimetric and Thermogravimetric Studies of Ball Milled Fe Doped Nanoscale La0.67Sr0.33MnO3 Manganite

    NASA Astrophysics Data System (ADS)

    Astik, Nidhi; Jha, Prafulla K.; Pratap, Arun

    2018-03-01

    The ball milling route has been used to produce the La0.67Sr0.33Mn0.85Fe0.15O3 (LSMFO) nanocrystalline sample from oxide precursors. The sample was characterized using x-ray diffraction (XRD), a scanning electron microscope (SEM), energy dispersive x-ray spectroscopy (EDAX), differential scanning calorimetry (DSC) and thermogravimetric (TGA) measurements. The x-ray diffraction confirms the phase purity of sample and shows that the sample crystallizes in the rhombohedral perovskite structure with a R-3c space group. The scanning electron micrograph shows the presence of well-faceted crystallites of LSMFO. The EDAX spectrum demonstrates the molar ratio of different elements of nanocrystalline LSMFO. Furthermore, the crystallite size using the Debye-Scherrer formula and William-Hall analysis has been found as 24 nm and 29 nm, respectively. Our results support the idea that a good quality nanocrystalline LSMFO sample can be obtained using the ball milling route. We also discuss the DSC and TGA curves and analyse the results in terms of phase transition, calcination temperature and activation barrier energies.

  9. Comparison of diffusion- and pumped-sampling methods to monitor volatile organic compounds in ground water, Massachusetts Military Reservation, Cape Cod, Massachusetts, July 1999-December 2002

    USGS Publications Warehouse

    Archfield, Stacey A.; LeBlanc, Denis R.

    2005-01-01

    To evaluate diffusion sampling as an alternative method to monitor volatile organic compound (VOC) concentrations in ground water, concentrations in samples collected by traditional pumped-sampling methods were compared to concentrations in samples collected by diffusion-sampling methods for 89 monitoring wells at or near the Massachusetts Military Reservation, Cape Cod. Samples were analyzed for 36 VOCs. There was no substantial difference between the utility of diffusion and pumped samples to detect the presence or absence of a VOC. In wells where VOCs were detected, diffusion-sample concentrations of tetrachloroethene (PCE) and trichloroethene (TCE) were significantly lower than pumped-sample concentrations. Because PCE and TCE concentrations detected in the wells dominated the calculation of many of the total VOC concentrations, when VOC concentrations were summed and compared by sampling method, visual inspection also showed a downward concentration bias in the diffusion-sample concentration. The degree to which pumped- and diffusion-sample concentrations agreed was not a result of variability inherent within the sampling methods or the diffusion process itself. A comparison of the degree of agreement in the results from the two methods to 13 quantifiable characteristics external to the sampling methods offered only well-screen length as being related to the degree of agreement between the methods; however, there is also evidence to indicate that the flushing rate of water through the well screen affected the agreement between the sampling methods. Despite poor agreement between the concentrations obtained by the two methods at some wells, the degree to which the concentrations agree at a given well is repeatable. A one-time, well-bywell comparison between diffusion- and pumped-sampling methods could determine which wells are good candidates for the use of diffusion samplers. For wells with good method agreement, the diffusion-sampling method is a time-saving and cost-effective alternative to pumped-sampling methods in a long-term monitoring program, such as at the Massachusetts Military Reservation.

  10. Comparative Analysis of Serum (Anti)oxidative Status Parameters in Healthy Persons

    PubMed Central

    Jansen, Eugène HJM; Ruskovska, Tatjana

    2013-01-01

    Five antioxidant and two oxidative stress assays were applied to serum samples of 43 healthy males. The antioxidant tests showed different inter-assay correlations. A very good correlation of 0.807 was observed between the ferric reducing ability of plasma (FRAP) and total antioxidant status (TAS) assay and also a fair correlation of 0.501 between the biological antioxidant potential (BAP) and TAS assay. There was no statistically significant correlation between the BAP and FRAP assay. The anti-oxidant assays have a high correlation with uric acid, especially the TAS (0.922) and FRAP assay (0.869). The BAP assay has a much lower and no statistically significant correlation with uric acid (0.302), which makes BAP more suitable for the antioxidant status. The total thiol assay showed no statistically significant correlation with uric acid (0.114). The total thiol assay, which is based on a completely different principle, showed a good and statistically significant correlation with the BAP assay (0.510) and also to the TAS assay, but to a lower and not significant extent (0.279) and not with the FRAP assay (−0.008). The oxy-adsorbent test (OXY) assay has no correlation with any of the other assays tested. The oxidative stress assays, reactive oxygen metabolites (ROM) and total oxidant status (TOS), based on a different principle, do not show a statistically significant correlation with the serum samples in this study. Both assays showed a negative, but not significant, correlation with the antioxidant assays. In conclusion, the ROM, TOS, BAP and TTP assays are based on different principles and will have an additional value when a combination of these assays will be applied in large-scale population studies. PMID:23507749

  11. Evaluation of an in-practice wet-chemistry analyzer using canine and feline serum samples.

    PubMed

    Irvine, Katherine L; Burt, Kay; Papasouliotis, Kostas

    2016-01-01

    A wet-chemistry biochemical analyzer was assessed for in-practice veterinary use. Its small size may mean a cost-effective method for low-throughput in-house biochemical analyses for first-opinion practice. The objectives of our study were to determine imprecision, total observed error, and acceptability of the analyzer for measurement of common canine and feline serum analytes, and to compare clinical sample results to those from a commercial reference analyzer. Imprecision was determined by within- and between-run repeatability for canine and feline pooled samples, and manufacturer-supplied quality control material (QCM). Total observed error (TEobs) was determined for pooled samples and QCM. Performance was assessed for canine and feline pooled samples by sigma metric determination. Agreement and errors between the in-practice and reference analyzers were determined for canine and feline clinical samples by Bland-Altman and Deming regression analyses. Within- and between-run precision was high for most analytes, and TEobs(%) was mostly lower than total allowable error. Performance based on sigma metrics was good (σ > 4) for many analytes and marginal (σ > 3) for most of the remainder. Correlation between the analyzers was very high for most canine analytes and high for most feline analytes. Between-analyzer bias was generally attributed to high constant error. The in-practice analyzer showed good overall performance, with only calcium and phosphate analyses identified as significantly problematic. Agreement for most analytes was insufficient for transposition of reference intervals, and we recommend that in-practice-specific reference intervals be established in the laboratory. © 2015 The Author(s).

  12. Relationship of various factors affecting the sustainable private forest management at Pajangan District, Special Regions Yogyakarta, Indonesia

    NASA Astrophysics Data System (ADS)

    Widayanto, B.; Karsidi, R.; Kusnandar; Sutrisno, J.

    2018-03-01

    Forests have a role and function in providing good atmosphere with stable oxygen content and affecting global climate stability. Good forest management will provide stable climatic conditions in global climate change. A good forest is managed to provide a sustainable environment condition. This study aims to analyze the relationship of various factors affecting the sustainability of private forests management. This research is a quantitative research with survey method and determination of sampling are was by purposive sampling. Sampling method using multiple stage cluster sampling with 60 samples. From the results it was found that the successful sustainable private forest management influenced by various factors, such as group dynamics, stakeholder support, community institutions, and farmer participation. The continuity of private forest management is determined by the fulfillment of economic, social and environmental dimensions. The most interesting finding is that the group dynamics conditions are very good, whereas the sense of togetherness among community is very strong under limited resources managing private forests. The sense of togetherness resulted creativity to diversify business and thus reduced the pressure in exploiting the forest. Some people think that managing the people's forest as a culture so that its existence can be more sustainable.

  13. Solid-phase microextraction of methadone in urine samples by electrochemically co-deposited sol-gel/Cu nanocomposite fiber.

    PubMed

    Mohammadiazar, Sirwan; Hasanli, Fateme; Maham, Mehdi; Payami Samarin, Somayeh

    2017-08-01

    Electrochemically co-deposited sol-gel/Cu nanocomposites have been introduced as a novel, simple and single-step technique for preparation of solid-phase microextraction (SPME) coating to extract methadone (MDN) (a synthetic opioid) in urine samples. The porous surface structure of the sol-gel/Cu nanocomposite coating was revealed by scanning electron microscopy. Direct immersion SPME followed by HPLC-UV determination was employed. The factors influencing the SPME procedure, such as the salt content, desorption solvent type, pH and equilibration time, were optimized. The best conditions were obtained with no salt content, acetonitrile as desorption solvent type, pH 9 and 10 min equilibration time. The calibration graphs for urine samples showed good linearity. The detection limit was about 0.2 ng mL -1 . Also, the novel method for preparation of nanocomposite fiber was compared with previously reported techniques for MDN determination. The results show that the novel nanocomposite fiber has relatively high extraction efficiency. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Effect of substrate porosity on photoluminescence properties of ZnS films prepared on porous Si substrates by pulsed laser deposition

    NASA Astrophysics Data System (ADS)

    Wang, Cai-Feng; Li, Qing-Shan; Zhang, Li-Chun; Lv, Lei; Qi, Hong-Xia

    2007-05-01

    ZnS films were deposited on porous Si (PS) substrates with different porosities by pulsed laser deposition. The photoluminescence spectra of the samples were measured to study the effect of substrate porosity on luminescence properties of ZnS/porous Si composites. After deposition of ZnS films, the red photoluminescence peak of porous Si shows a slight blueshift compared with as-prepared porous Si samples. With an increase of the porosity, a green emission at about 550 nm was observed which may be ascribed to the defect-center luminescence of ZnS films, and the photoluminescence of ZnS/porous Si composites is very close to white light. Good crystal structures of the samples were observed by x-ray diffraction, showing that ZnS films were grown in preferred orientation. Due to the roughness of porous Si surface, some cracks appear in ZnS films, which could be seen from scanning electron microscope images.

  15. Preparation of Gd(OH){sub 3} large single crystals by solid KOH assisted hydrothermal method and their luminescent and magnetic properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Hai; Zhang, Youjin, E-mail: zyj@ustc.edu.cn; Zhou, Maozhong

    Highlights: • Gd(OH){sub 3} large single crystals were prepared by solid KOH assisted hydrothermal method. • The possible growth mechanism of Gd(OH){sub 3} large single crystals was proposed. • The Gd(OH){sub 3} samples emitted a strong narrow-band ultraviolet B (NB-UVB) light. • The Gd(OH){sub 3} samples showed good paramagnetic properties. - Abstract: Large single crystals of gadolinium hydroxide [Gd(OH){sub 3}] in the length of several millimeters were successfully prepared by using solid KOH assisted hydrothermal method. Gd(OH){sub 3} samples were characterized by X-ray diffraction (XRD), 4-circle single-crystal diffraction, Fourier transform infrared (FTIR) spectroscopy and X-ray photoelectron spectroscopy (XPS). FESEM imagemore » shows hexagonal prism morphology for the Gd(OH){sub 3} large crystals. The possible growth mechanism of Gd(OH){sub 3} large single crystals was proposed. The photoluminescence and magnetic properties of Gd(OH){sub 3} species were investigated.« less

  16. [The Family Questionnaire (FB-K) - A Short Version of the General Family Questionnaire and its Reliability and Validity].

    PubMed

    Sidor, Anna; Cierpka, Manfred

    2016-01-01

    A standardized assessment of a family system plays a crucial role in family therapy research and diagnostic, as well as in a family therapy itself. A 14-item short version of the General Family Questionnaire (FB-K) was designed to get a tool for assessing family functionality that is low time-consuming. The short version was developed by factor analysis from the long version FA-A. The quality criteria of the family questionnaire were verified in a control sample of 208 high-risk families four months after the birth of their child. The new family questionnaire demonstrates a very good reliability and a satisfactory 8-months-stability. The concurrent validity with the FACES scale "cohesion" is assured. Regarding the construct validity a positive correlation to the feeling of coherence was found. The family questionnaire shows a negative correlation to the maternal postnatal depressive symptoms, the degree of maternal stress burden, the dysfunctionality of the mother-child-relationship and impaired bonding. The values taken from a norm sample with infants are higher by trend and in the sample with children under 18 do not deviate from the values of the risk sample. FB-K covers two aspects of family functioning, the bond between family members and their willingness to communicate. The internal consistency of FB-K is excellent, the criterion and the construct validity are good.

  17. Performance of laboratories analysing welding fume on filter samples: results from the WASP proficiency testing scheme.

    PubMed

    Stacey, Peter; Butler, Owen

    2008-06-01

    This paper emphasizes the need for occupational hygiene professionals to require evidence of the quality of welding fume data from analytical laboratories. The measurement of metals in welding fume using atomic spectrometric techniques is a complex analysis often requiring specialist digestion procedures. The results from a trial programme testing the proficiency of laboratories in the Workplace Analysis Scheme for Proficiency (WASP) to measure potentially harmful metals in several different types of welding fume showed that most laboratories underestimated the mass of analyte on the filters. The average recovery was 70-80% of the target value and >20% of reported recoveries for some of the more difficult welding fume matrices were <50%. This level of under-reporting has significant implications for any health or hygiene studies of the exposure of welders to toxic metals for the types of fumes included in this study. Good laboratories' performance measuring spiked WASP filter samples containing soluble metal salts did not guarantee good performance when measuring the more complex welding fume trial filter samples. Consistent rather than erratic error predominated, suggesting that the main analytical factor contributing to the differences between the target values and results was the effectiveness of the sample preparation procedures used by participating laboratories. It is concluded that, with practice and regular participation in WASP, performance can improve over time.

  18. Dried blood spot assay for the quantification of phenytoin using Liquid Chromatography-Mass Spectrometry.

    PubMed

    Villanelli, Fabio; Giocaliere, Elisa; Malvagia, Sabrina; Rosati, Anna; Forni, Giulia; Funghini, Silvia; Shokry, Engy; Ombrone, Daniela; Della Bona, Maria Luisa; Guerrini, Renzo; la Marca, Giancarlo

    2015-02-02

    Phenytoin (PHT) is one of the most commonly used anticonvulsant drugs for the treatment of epilepsy and bipolar disorders. The large amount of plasma required by conventional methods for drug quantification makes mass spectrometry combined with dried blood spot (DBS) sampling crucial for pediatric patients where therapeutic drug monitoring or pharmacokinetic studies may be difficult to realize. DBS represents a new convenient sampling support requiring minimally invasive blood drawing and providing long-term stability of samples and less expensive shipment and storage. The aim of this study was to develop a LC-MS/MS method for the quantification of PHT on DBS. This analytical method was validated and gave good linearity (r(2)=0.999) in the range of 0-100mg/l. LOQ and LOD were 1.0mg/l and 0.3mg/l, respectively. The drug extraction from paper was performed in a few minutes using a mixture composed of organic solvent for 80%. The recovery ranged from 85 to 90%; PHT in DBS showed to be stable at different storage temperatures for one month. A good correlation was also obtained between PHT plasma and DBS concentrations. This method is both precise and accurate and appears to be particularly suitable to monitor treatment with a simple and convenient sample collection procedure. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Preparation of a Co-doped hierarchically porous carbon from Co/Zn-ZIF: An efficient adsorbent for the extraction of trizine herbicides from environment water and white gourd samples.

    PubMed

    Jiao, Caina; Li, Menghua; Ma, Ruiyang; Wang, Chun; Wu, Qiuhua; Wang, Zhi

    2016-05-15

    A Co-doped hierarchically porous carbon (Co/HPC) was synthesized through a facile carbonization process by using Co/ZIF-8 as the precursor. The textures of the Co/HPC were investigated by scanning electron microscopy, transmission electron microscopy, X-ray diffraction, vibration sample magnetometry and nitrogen adsorption-desorption isotherms. The results showed that the Co/HPC is in good polyhedral shape with uniform size, sufficient magnetism, high surface area as well as hierarchical pores (micro-, meso- and macropores). To evaluate the extraction performance of the Co/HPC, it was applied as a magnetic adsorbent for the enrichment of triazine herbicides from environment water and white gourd samples prior to high performance liquid chromatographic analysis. The main parameters that affected the extraction efficiency were investigated. Under the optimum conditions, a good linearity for the four triazine herbicides was achieved with the correlation coefficients (r) higher than 0.9970. The limits of detection, based on S/N=3, were 0.02 ng/mL for water and 0.1-0.2 ng/g for white gourd samples, respectively. The recoveries of all the analytes for the method fell in the range from 80.3% to 120.6%. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Using Language Sample Analysis in Clinical Practice: Measures of Grammatical Accuracy for Identifying Language Impairment in Preschool and School-Aged Children.

    PubMed

    Eisenberg, Sarita; Guo, Ling-Yu

    2016-05-01

    This article reviews the existing literature on the diagnostic accuracy of two grammatical accuracy measures for differentiating children with and without language impairment (LI) at preschool and early school age based on language samples. The first measure, the finite verb morphology composite (FVMC), is a narrow grammatical measure that computes children's overall accuracy of four verb tense morphemes. The second measure, percent grammatical utterances (PGU), is a broader grammatical measure that computes children's accuracy in producing grammatical utterances. The extant studies show that FVMC demonstrates acceptable (i.e., 80 to 89% accurate) to good (i.e., 90% accurate or higher) diagnostic accuracy for children between 4;0 (years;months) and 6;11 in conversational or narrative samples. In contrast, PGU yields acceptable to good diagnostic accuracy for children between 3;0 and 8;11 regardless of sample types. Given the diagnostic accuracy shown in the literature, we suggest that FVMC and PGU can be used as one piece of evidence for identifying children with LI in assessment when appropriate. However, FVMC or PGU should not be used as therapy goals directly. Instead, when children are low in FVMC or PGU, we suggest that follow-up analyses should be conducted to determine the verb tense morphemes or grammatical structures that children have difficulty with. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. Effect of nitrogen fertilisation on the overall quality of minimally processed globe artichoke heads.

    PubMed

    Lombardo, Sara; Restuccia, Cristina; Muratore, Giuseppe; Barbagallo, Riccardo N; Licciardello, Fabio; Pandino, Gaetano; Scifò, Giovanna O; Mazzaglia, Agata; Ragonese, Francesca; Mauromicale, Giovanni

    2017-01-01

    Although nitrogen (N) fertilisation is essential for promoting crop yield, it may also affect the produce quality. Here, the influence of three N fertiliser rates (0 kg ha -1 as a control, 200 kg ha -1 and 400 kg ha -1 referred to as N 0 , N 200 and N 400 , respectively) on the overall quality of minimally processed globe artichoke heads was investigated during refrigerated storage for 12 days. Throughout the storage time, N fertilised samples had higher inulin contents than those unfertilised. In addition, the respiratory quotient of N 200 and N 400 samples was 2-fold and 2.5-fold lower than N 0 ones, whose values were close to the normal range for vegetables. All the samples reported good microbiological standards, although N 200 and N 400 achieved lower mesophilic and psychotropic counts than N 0 throughout the storage time. After 8 and 12 days of refrigerated storage, the N 200 samples showed the highest scores of positive sensory descriptors. A fertiliser level of 200 kg N ha -1 is suitable for obtaining minimally processed globe artichoke heads with good nutritional, sensory and microbiological quality, characterised by low endogenous oxidase activities. Proper packaging systems and procedures are, however, crucial for extending the product shelf-life and, thus, promoting its exportation on a wider scale. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  2. Determination of parabens and endocrine-disrupting alkylphenols in soil by gas chromatography-mass spectrometry following matrix solid-phase dispersion or in-column microwave-assisted extraction: a comparative study.

    PubMed

    Pérez, R A; Albero, B; Miguel, E; Sánchez-Brunete, C

    2012-03-01

    Two rapid methods were evaluated for the simultaneous extraction of seven parabens and two alkylphenols from soil based on matrix solid-phase dispersion (MSPD) and microwave-assisted extraction (MAE). Soil extracts were derivatized with N,O-bis(trimethylsilyl)trifluoroacetamide and analyzed by gas chromatography with mass spectrometry. Extraction and clean-up of samples were carried out by both methods in a single step. A glass sample holder, inside the microwave cell, was used in MAE to allow the simultaneous extraction and clean-up of samples and shorten the MAE procedure. The detection limits achieved by MSPD were lower than those obtained by MAE because the presence of matrix interferences increased with this extraction method. The extraction yields obtained by MSPD and MAE for three different types of soils were compared. Both procedures showed good recoveries and sensitivity for the determination of parabens and alkylphenols in two of the soils assayed, however, only MSPD yielded good recoveries with the other soil. Finally, MSPD was applied to the analysis of soils collected in different sites of Spain. In most of the samples analyzed, methylparaben and butylparaben were detected at levels ranging from 1.21 to 8.04 ng g(-1) dry weight and 0.48 to 1.02 ng g(-1) dry weight, respectively.

  3. Performance evaluation of a novel chemiluminescence assay for detection of anti-GBM antibodies: an international multicenter study.

    PubMed

    Mahler, Michael; Radice, Antonella; Sinico, Renato A; Damoiseaux, Jan; Seaman, Andrea; Buckmelter, Kristen; Vizjak, Alenka; Buchner, Carol; Binder, Walter L; Fritzler, Marvin J; Cui, Zhao

    2012-01-01

    Autoantibodies to the non-collagen region (NC1) of the alpha-3 subunit of collagen IV represent a serological hallmark in the diagnosis of Goodpasture's syndrome (GPS). The objective of our study was to carefully analyze the performance characteristics of a novel anti-glomerular basement membrane (GBM) chemiluminescence immunoassay (CIA). Sera from patients with GPS (n = 90) were collected from four clinical centers. Samples from different disease groups (n = 397) and healthy individuals (n = 400) were used as controls. All samples were tested for anti-GBM antibodies by a rapid, random access CIA (QUANTA Flash™ GBM). Most of the samples were also tested using other methods including different commercial anti-GBM IgG assays and research assays for anti-GBM IgA and IgM. The sensitivity and specificity of the novel CIA was 95.6% [95% confidence interval (CI) 89.0-98.8%] and 99.6% (95% CI 98.9-99.9%), respectively. Receiver operating characteristic analysis showed good discrimination between GPS patients and controls. The area under the curve was 0.98 (CI 0.96-1.0). The three anti-GBM antibody-positive samples from the control group were from two healthy individuals and one human immunodeficiency virus (HIV)-infected patient. All three individuals had low levels of anti-GBM antibodies [20, 24 and 25 chemiluminescent unit (CU), cutoff 20 CU]. When the results of the new CIA were compared to other methods, good agreement was observed: 95.8% (kappa = 0.92) versus EliA™ GBM, 97.4% (kappa = 0.95) versus both BINDAZYME™ Anti-GBM and QUANTA Lite® GBM. Anti-GBM IgA was detectable in low concentrations in patients with GPS and was associated with anti-GBM IgG but was less useful in discriminating GPS patients and controls. No discrimination was found for anti-GBM IgM. The novel QUANTA Flash™ GBM CIA demonstrated good sensitivity and specificity and had good agreement with other methods. Our data confirm that ∼5% of patients with GPS do not have detectable levels of anti-GBM antibodies.

  4. Grain size statistics and depositional pattern of the Ecca Group sandstones, Karoo Supergroup in the Eastern Cape Province, South Africa

    NASA Astrophysics Data System (ADS)

    Baiyegunhi, Christopher; Liu, Kuiwu; Gwavava, Oswald

    2017-11-01

    Grain size analysis is a vital sedimentological tool used to unravel the hydrodynamic conditions, mode of transportation and deposition of detrital sediments. In this study, detailed grain-size analysis was carried out on thirty-five sandstone samples from the Ecca Group in the Eastern Cape Province of South Africa. Grain-size statistical parameters, bivariate analysis, linear discriminate functions, Passega diagrams and log-probability curves were used to reveal the depositional processes, sedimentation mechanisms, hydrodynamic energy conditions and to discriminate different depositional environments. The grain-size parameters show that most of the sandstones are very fine to fine grained, moderately well sorted, mostly near-symmetrical and mesokurtic in nature. The abundance of very fine to fine grained sandstones indicate the dominance of low energy environment. The bivariate plots show that the samples are mostly grouped, except for the Prince Albert samples that show scattered trend, which is due to the either mixture of two modes in equal proportion in bimodal sediments or good sorting in unimodal sediments. The linear discriminant function analysis is dominantly indicative of turbidity current deposits under shallow marine environments for samples from the Prince Albert, Collingham and Ripon Formations, while those samples from the Fort Brown Formation are lacustrine or deltaic deposits. The C-M plots indicated that the sediments were deposited mainly by suspension and saltation, and graded suspension. Visher diagrams show that saltation is the major process of transportation, followed by suspension.

  5. Evaluation of urine for Leishmania infantum DNA detection by real-time quantitative PCR.

    PubMed

    Pessoa-E-Silva, Rômulo; Mendonça Trajano-Silva, Lays Adrianne; Lopes da Silva, Maria Almerice; da Cunha Gonçalves-de-Albuquerque, Suênia; de Goes, Tayná Correia; Silva de Morais, Rayana Carla; Lopes de Melo, Fábio; de Paiva-Cavalcanti, Milena

    2016-12-01

    The availability of some sorts of biological samples which require noninvasive collection methods has led to an even greater interest in applying molecular biology on visceral leishmaniasis (VL) diagnosis, since these samples increase the safety and comfort of both patients and health professionals. In this context, this work aimed to evaluate the suitability of the urine as a specimen for Leishmania infantum kinetoplast DNA detection by real-time quantitative PCR (qPCR). Subsequent to the reproducibility analysis, the detection limit of the qPCR assay was set at 5fg (~0.025 parasites) per μL of urine. From the comparative analysis performed with a set of diagnostic criteria (serological and molecular reference tests), concordance value of 96.08% was obtained (VL-suspected and HIV/AIDS patients, n=51) (P>0.05). Kappa coefficient (95% CI) indicated a good agreement between the test and the set of diagnostic criteria (k=0.778±0.151). The detection of Leishmania DNA in urine by qPCR was possible in untreated individuals, and in those with or without suggestive renal impairment. Fast depletion of the parasite's DNA in urine after treatment (from one dose of meglumine antimoniate) was suggested by negative qPCR results, thus indicating it as a potential alternative specimen to follow up the efficacy of therapeutic approaches. Even when evaluated in a clinically heterogeneous set of patients, the urine showed good prospect as sample for VL diagnosis by qPCR, also indicating a good negative predictive value for untreated suspected patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. [Content determination of twelve major components in Tibetan medicine Zuozhu Daxi by UPLC].

    PubMed

    Qu, Yan; Li, Jin-hua; Zhang, Chen; Li, Chun-xue; Dong, Hong-jiao; Wang, Chang-sheng; Zeng, Rui; Chen, Xiao-hu

    2015-05-01

    A quantitative analytical method of ultra-high performance liquid chromatography (UPLC) was developed for simultaneously determining twelve components in Tibetan medicine Zuozhu Daxi. SIMPCA 12.0 software was used a principal component analysis PCA) and partial small squares analysis (PLSD-DA) on the twelve components in 10 batches from four pharmaceutical factories. Acquity UPLC BEH C15 column (2.1 mm x 100 mm, 1.7 µm) was adopted at the column temperature of 35 °C and eluted with acetonitrile (A) -0.05% phosphate acid solution (B) as the mobile phase with a flow rate of 0. 3 mL · min(-1). The injection volume was 1 µL. The detection wavelengths were set at 210 nm for alantolactone, isoalantolactone and oleanolic; 260 nm for trychnine and brucine; 288 nm for protopine; 306 nm for protopine, resveratrol and piperine; 370 nm for quercetin and isorhamnetin. The results showed a good separation among index components, with a good linearity relationship (R2 = 0.999 6) within the selected concentration range. The average sample recovery rates ranged between 99.44%-101.8%, with RSD between 0.37%-1.7%, indicating the method is rapid and accurate with a good repeatability and stability. The PCA and PLSD-DA analysis on the sample determination results revealed a great difference among samples from different pharmaceutical factories. The twelve components included in this study contributed significantly to the quantitative determination of intrinsic quality of Zuozhu Daxi. The UPLC established for to the quantitative determination of the twelve components can provide scientific basis for the comprehensive quality evaluation of Zuozhu Daxi.

  7. Development of fire shutters based on numerical optimizations

    NASA Astrophysics Data System (ADS)

    Novak, Ondrej; Kulhavy, Petr; Martinec, Tomas; Petru, Michal; Srb, Pavel

    2018-06-01

    This article deals with a prototype concept, real experiment and numerical simulation of a layered industrial fire shutter, based on some new insulating composite materials. The real fire shutter has been developed and optimized in laboratory and subsequently tested in the certified test room. A simulation of whole concept has been carried out as the non-premixed combustion process in the commercial final volume sw Pyrosim. Model of the combustion based on a stoichiometric defined mixture of gas and the tested layered samples showed good conformity with experimental results - i.e. thermal distribution inside and heat release rate that has gone through the sample.

  8. Improved conductivity of carbon-nano-fiber (CNF)/polytetrafluoroethylene (PTFE) composite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chandra, Sarita; Kalra, G. S.; Pushkar, Vinay K.

    2016-05-23

    A series of CNF/PTFE composite loaded with different weight % of CNFs as 0.01, 0.02, 0.03, 0.05, 1, 2, 3, 4, 5 into PTFE is fabricated. In this work, the 5wt% heat-treated CNFs were used as filler in PTFE. Current-voltage (I-V) study of the samples confirmed the samples as conducting composite. In scanning electron microscope (SEM) study, the conducting CNFs channels were observed from upper surface to inside throughout the polymer matrix. A sintered composite of 5 wt% loading of CNFs showed an improved conductivity and SEM image exhibited a good binding of CNFs into PTFE.

  9. Thickness determination of biological samples with a zeta-calibrated scanning tunneling microscope.

    PubMed Central

    Wang, Z H; Hartmann, T; Baumeister, W; Guckenberger, R

    1990-01-01

    A single-tube scanning tunneling microscope has been zeta-calibrated by using atomic steps of crystalline gold and was used for measuring the thickness of two biological samples, metal-coated as well as uncoated. The hexagonal surface layer of the bacterium Deinococcus radiodurans with an open network-type structure shows thickness values that are strongly influenced by the substrate and the preparation method. In contrast, the thickness of the purple membrane of Halobacterium halobium with its densely packed less-corrugated structure exhibits very little variation in thickness in coated preparations and the values obtained are in good agreement with x-ray data. Images PMID:2251276

  10. Determination of organic acids in tissues and exudates of maize, lupin, and chickpea by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Erro, Javier; Zamarreño, Angel M; Yvin, Jean-Claude; Garcia-Mina, Jose M

    2009-05-27

    This article describes a fast and simple methodology for the extraction and determination of organic acids in tissues and root exudates of maize, lupin, and chickpea by LC/MS/MS. Its main advantage is that it does not require sample prepurification before HPLC analysis or sample derivatization to improve sensibility. The results obtained showed good precision and accuracy, a recovery close to 100%, and no significant matrix effect. Moreover, the sensibility of the method is in general better than that of previously described methodologies, with detection limits between 15 and 900 pg injected.

  11. Benchmark studies of induced radioactivity produced in LHC materials, Part I: Specific activities.

    PubMed

    Brugger, M; Khater, H; Mayer, S; Prinz, A; Roesler, S; Ulrici, L; Vincke, H

    2005-01-01

    Samples of materials which will be used in the LHC machine for shielding and construction components were irradiated in the stray radiation field of the CERN-EU high-energy reference field facility. After irradiation, the specific activities induced in the various samples were analysed with a high-precision gamma spectrometer at various cooling times, allowing identification of isotopes with a wide range of half-lives. Furthermore, the irradiation experiment was simulated in detail with the FLUKA Monte Carlo code. A comparison of measured and calculated specific activities shows good agreement, supporting the use of FLUKA for estimating the level of induced activity in the LHC.

  12. Direct magnetocaloric characterization and simulation of thermomagnetic cycles

    NASA Astrophysics Data System (ADS)

    Porcari, G.; Buzzi, M.; Cugini, F.; Pellicelli, R.; Pernechele, C.; Caron, L.; Brück, E.; Solzi, M.

    2013-07-01

    An experimental setup for the direct measurement of the magnetocaloric effect capable of simulating high frequency magnetothermal cycles on laboratory-scale samples is described. The study of the magnetocaloric properties of working materials under operative conditions is fundamental for the development of innovative devices. Frequency and time dependent characterization can provide essential information on intrinsic features such as magnetic field induced fatigue in materials undergoing first order magnetic phase transitions. A full characterization of the adiabatic temperature change performed for a sample of Gadolinium across its Curie transition shows the good agreement between our results and literature data and in-field differential scanning calorimetry.

  13. Determination of beta emitters ( 90Sr, 14C and 3H) in routine measurements using plastic scintillation beads

    NASA Astrophysics Data System (ADS)

    Tarancón, A.; García, J. F.; Rauret, G.

    2004-01-01

    Plastic scintillation has recently been shown to be a powerful alternative to liquid scintillation and Cherenkov techniques in radionuclide determination due to the good values obtained for the measurement parameters and the low amount of wastes generated. The present study evaluated the capability of plastic scintillation beads and polyethylene vials for routine measurements of beta emitters ( 90Sr, 14C, 3H). Results show that high- and medium-energetic beta emitters can be quantified with relative errors less than 5% in low-activity aqueous samples, whereas low-energetic beta emitters can only be quantified in medium-activity samples.

  14. Ability to Reach Orgasm in Patients With Prostate Cancer Treated With Robot-assisted Laparoscopic Prostatectomy.

    PubMed

    Østby-Deglum, Marie; Axcrona, Karol; Brennhovd, Bjørn; Dahl, Alv A

    2016-06-01

    To study the ability to reach orgasm after robot-assisted laparoscopic prostatectomy (RALP) in relation to demographic, cancer-related, and surgical variables, and the use of erectile aids. In this cross-sectional study at a mean of 3 years after RALP at Oslo University Hospital, 982 men were invited to complete a mailed questionnaire, and 777 responded. Respondents who reported postoperative radiotherapy or hormone treatment, or did not report on orgasm were omitted, leaving 609 patients for analysis. Ability to reach orgasm was rated on 1 question from The Expanded Prostate Cancer Index Composite 26-item version, and dichotomized into "good" or "poor." Overall, 27% of the men reported good ability to reach orgasm: 22% among those did not use erectile aids and 34% among those did (P = .001). Univariate analysis of men with good versus poor ability to reach orgasm showed many significant differences. In multivariate analysis, being older, having a reduced physical quality of life, and erectile dysfunction were significantly associated with poor ability to reach orgasm. Erectile dysfunction showed an odds ratio of 4.86 for poor orgasmic ability. The 48% of men who used erectile aids had significantly better orgasmic ability than the nonusers. In our sample, 27% had good ability to reach orgasm at a mean of 3 years after RALP. Poor orgasmic ability was associated with being older, poor erectile function, and a reduced physical quality of life. Using erectile aids increased the rate of good ability to reach orgasm. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Pellet starters in layering technique using concentrated drug solution.

    PubMed

    Gryczová, Eva; Rabisková, Miloslava; Vetchý, David; Krejcová, Katerina

    2008-12-01

    Characteristics of inert starters in drug solution layering are important for successful active pellet formation. Four types of starters composed of sucrose or microcrystalline cellulose (MCC) or lactose and MCC were compared in our study. The active pellets were prepared using Wurster type apparatus. Yield and pellet quality parameters were determined. The highest yield (85.66-89.41%) was obtained for cores composed of MCC due to their insolubility in water (the drug solvent) and good mechanical properties. On the contrary, soluble and brittle sucrose cores dissolved partially during the process forming undesirable agglomerates and giving lower yield (76.2%). All pellet samples showed good flow properties and drug content from 82.4 to 94.5% of the theoretical drug amount.

  16. Development of europium doped BaSO4 TL OSL dual phosphor for radiation dosimetry applications

    NASA Astrophysics Data System (ADS)

    Patle, Anita; Patil, R. R.; Kulkarni, M. S.; Bhatt, B. C.; Moharil, S. V.

    2015-08-01

    This paper presents the results on the preparation and characterization of Europium-doped Barium sulfate (BaSO4: Eu) TL /OSL dual phosphor. The OSL sensitivity was found to be 11% of the commercially available Al2O3: C, using area integration method. The sample also shows good TL sensitivity and the dosimetric peak appears around 190°C with a shoulder at 282°C. After OSL readout, No change in the TL glow curve is observed. Since the observed TL peaks are not responsible for the observed OSL, good OSL as well as TL sensitivity and low fading will make this phosphor suitable for applications in radiation dosimetry using OSL as well as TL.

  17. Properties of DRGs, LBGs, and BzK Galaxies in the GOODS South Field

    NASA Astrophysics Data System (ADS)

    Grazian, A.; Salimbeni, S.; Pentericci, L.; Fontana, A.; Santini, P.; Giallongo, E.; de Santis, C.; Gallozzi, S.; Nonino, M.; Cristiani, S.; Vanzella, E.

    2007-12-01

    We use the GOODS-MUSIC catalog with multi-wavelength coverage extending from the U band to the Spitzer 8 μm band, and spectroscopic or accurate photometric redshifts to select samples of BM/BX/LBGs, DRGs, and BzK galaxies. We discuss the overlap and the limitations of these selection criteria, which can be overcome with a criterion based on physical parameters (age and star formation timescale). We show that the BzK-PE criterion is not optimal for selecting early type galaxies at the faint end. We also find that LBGs and DRGs contribute almost equally to the global Stellar Mass Density (SMD) at z≥ 2 and in general that star forming galaxies form a substantial fraction of the universal SMD.

  18. Math Anxiety Assessment with the Abbreviated Math Anxiety Scale: Applicability and Usefulness: Insights from the Polish Adaptation

    PubMed Central

    Cipora, Krzysztof; Szczygieł, Monika; Willmes, Klaus; Nuerk, Hans-Christoph

    2015-01-01

    Math anxiety has an important impact on mathematical development and performance. However, although math anxiety is supposed to be a transcultural trait, assessment instruments are scarce and are validated mainly for Western cultures so far. Therefore, we aimed at examining the transcultural generality of math anxiety by a thorough investigation of the validity of math anxiety assessment in Eastern Europe. We investigated the validity and reliability of a Polish adaptation of the Abbreviated Math Anxiety Scale (AMAS), known to have very good psychometric characteristics in its original, American-English version as well as in its Italian and Iranian adaptations. We also observed high reliability, both for internal consistency and test-retest stability of the AMAS in the Polish sample. The results also show very good construct, convergent and discriminant validity: The factorial structure in Polish adult participants (n = 857) was very similar to the one previously found in other samples; AMAS scores correlated moderately in expected directions with state and trait anxiety, self-assessed math achievement and skill as well temperamental traits of emotional reactivity, briskness, endurance, and perseverance. Average scores obtained by participants as well as gender differences and correlations with external measures were also similar across cultures. Beyond the cultural comparison, we used path model analyses to show that math anxiety relates to math grades and self-competence when controlling for trait anxiety. The current study shows transcultural validity of math anxiety assessment with the AMAS. PMID:26648893

  19. Math Anxiety Assessment with the Abbreviated Math Anxiety Scale: Applicability and Usefulness: Insights from the Polish Adaptation.

    PubMed

    Cipora, Krzysztof; Szczygieł, Monika; Willmes, Klaus; Nuerk, Hans-Christoph

    2015-01-01

    Math anxiety has an important impact on mathematical development and performance. However, although math anxiety is supposed to be a transcultural trait, assessment instruments are scarce and are validated mainly for Western cultures so far. Therefore, we aimed at examining the transcultural generality of math anxiety by a thorough investigation of the validity of math anxiety assessment in Eastern Europe. We investigated the validity and reliability of a Polish adaptation of the Abbreviated Math Anxiety Scale (AMAS), known to have very good psychometric characteristics in its original, American-English version as well as in its Italian and Iranian adaptations. We also observed high reliability, both for internal consistency and test-retest stability of the AMAS in the Polish sample. The results also show very good construct, convergent and discriminant validity: The factorial structure in Polish adult participants (n = 857) was very similar to the one previously found in other samples; AMAS scores correlated moderately in expected directions with state and trait anxiety, self-assessed math achievement and skill as well temperamental traits of emotional reactivity, briskness, endurance, and perseverance. Average scores obtained by participants as well as gender differences and correlations with external measures were also similar across cultures. Beyond the cultural comparison, we used path model analyses to show that math anxiety relates to math grades and self-competence when controlling for trait anxiety. The current study shows transcultural validity of math anxiety assessment with the AMAS.

  20. Determinations of rare earth element abundance and U-Pb age of zircons using multispot laser ablation-inductively coupled plasma mass spectrometry.

    PubMed

    Yokoyama, Takaomi D; Suzuki, Toshihiro; Kon, Yoshiaki; Hirata, Takafumi

    2011-12-01

    We have developed a new calibration technique for multielement determination and U-Pb dating of zircon samples using laser ablation-inductively coupled plasma mass spectrometry (ICPMS) coupled with galvanometric optics. With the galvanometric optics, laser ablation of two or more sample materials could be achieved in very short time intervals (~10 ms). The resulting sample aerosols released from different ablation pits or different solid samples were mixed and homogenized within the sample cell and then transported into the ICP ion source. Multiple spot laser ablation enables spiking of analytes or internal standard elements directly into the solid samples, and therefore the standard addition calibration method can be applied for the determination of trace elements in solid samples. In this study, we have measured the rare earth element (REE) abundances of two zircon samples (Nancy 91500 and Prešovice) based on the standard addition technique, using a direct spiking of analytes through a multispot laser ablation of the glass standard material (NIST SRM612). The resulting REE abundance data show good agreement with previously reported values within analytical uncertainties achieved in this study (10% for most elements). Our experiments demonstrated that nonspectroscopic interferences on 14 REEs could be significantly reduced by the standard addition technique employed here. Another advantage of galvanometric devices is the accumulation of sample aerosol released from multiple spots. In this study we have measured the U-Pb age of a zircon sample (LMR) using an accumulation of sample aerosols released from 10 separate ablation pits of low diameters (~8 μm). The resulting (238)U-(206)Pb age data for the LMR zircons was 369 ± 64 Ma, which is in good agreement with previously reported age data (367.6 ± 1.5 Ma). (1) The data obtained here clearly demonstrate that the multiple spot laser ablation-ICPMS technique can become a powerful approach for elemental and isotopic ratio measurements in solid materials.

  1. 7 CFR 51.485 - Good internal quality.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Good internal quality. 51.485 Section 51.485... STANDARDS) United States Standards for Grades of Cantaloups 1 Definitions § 51.485 Good internal quality. Good internal quality means that the combined juice from the edible portion of a sample of cantaloups...

  2. Probiotic Properties of Lactobacillus plantarum RYPR1 from an Indigenous Fermented Beverage Raabadi

    PubMed Central

    Yadav, Ruby; Puniya, Anil K.; Shukla, Pratyoosh

    2016-01-01

    Present study documents the potential probiotic Lactobacillus isolated from indigenous fermented beverage Raabadi, consumed during summers in Haryana and Rajasthan regions of India. A total of five Raabadi samples were collected aseptically and 54 isolates were purified using MRS medium. All the isolates were assessed for tolerance to low pH and bile salts. It was observed that out of 54 only 24 isolates could survive the simulated gastric conditions. These isolates were further evaluated in vitro for cell surface hydrophobicity, cell surface hydrophobicity, hypocholesteramic activity, anti-oxidative potential, BSH activity, antagonistic activity, and antibiotic resistance profile. In addition, the confirmation of phenol resistance was also done. On the basis of results obtained, the survival rate of isolates was noted and six isolates were finally selected for further studies. Among them Lactobacillus plantarum RYPR1 and RYPC7 showed good survival at pH 2 which shows good acid tolerance. Moreover, L. plantarum RYPR1 showed the highest hydrophobicity (79.13%) and represented the deconjugation of bile salts, which help in their adhesion to epithelial cells and colonization. Furthermore, RYPR1 also exhibited highest cholesterol reduction (59%) and subsequent analysis of results revealed that the above mentioned isolates further exhibit a good hypocholesterolemic effect and could be possibly used to prevent hypercholesterolemia. The present study divulges that L. plantarum RYPR1 has an excellent probiotic potential. PMID:27818658

  3. Influence of alkalinity, hardness and dissolved solids on drinking water taste: A case study of consumer satisfaction.

    PubMed

    Lou, Jie-Chung; Lee, Wei-Li; Han, Jia-Yun

    2007-01-01

    Two surveys of consumer satisfaction with drinking water conducted by Taiwan Water Supply Corp. are presented in this study. The study results show that although a lot of money was invested to modify traditional treatment processes, over 60% of local residents still avoided drinking tap water. Over half of the respondents felt that sample TT (from the traditional treatment process) was not a good drinking water, whether in the first or second survey, whereas almost 60% of respondents felt that samples PA, PB, CCL and CT (from advanced treatment processes) were good to drink. For all drinking water samples, respondent satisfaction with a sample primarily depended on it having no unpleasant flavors. Taiwan Environmental Protection Administration plans to revise the drinking water quality standards for TH and TDS in the near future. The new standards require a lower TH concentration (from currently 400mg/L (as CaCO(3)) to 150mg/L (as CaCO(3))), and a lower TDS maximum admissible concentration from the current guideline of 600 to 250mg/L. Therefore, this study also evaluated the impacts on drinking water tastes caused by variations in TH and TDS concentrations, and assessed the need to issue more strict drinking water quality standards for TH and TDS. The research results showed that most respondents could not tell the difference in water taste among water samples with different TDS, TH and alkalinity. Furthermore, hardness was found to be inversely associated with cardiovascular diseases and cancers, and complying with more strict standards would lead most water facilities to invest billions of dollars to upgrade their treatment processes. Consequently, in terms of drinking water tastes alone, this study suggested that Taiwan Environmental Protection Administration should conduct more thorough reviews of the scientific literature that provides the rationale for setting standards and reconsider if it is necessary to revise drinking water quality standards for TH and TDS.

  4. Glyoxal and methylglyoxal in Atlantic seawater and marine aerosol particles: method development and first application during the Polarstern cruise ANT XXVII/4

    NASA Astrophysics Data System (ADS)

    van Pinxteren, M.; Herrmann, H.

    2013-12-01

    An analytical method for the determination of the alpha dicarbonyls glyoxal (GLY) and methylglyoxal (MGLY) from seawater and marine aerosol particles is presented. The method is based on derivatization with o-(2,3,4,5,6-Pentafluorobenzyl)-hydroxylamine (PFBHA) reagent, solvent extraction and GC-MS (SIM) analysis. The method showed good precision (RSD < 10%), sensitivity (detection limits in the low ng L-1 range), and accuracy (good agreement between external calibration and standard addition). The method was applied to determine GLY and MGLY in oceanic water sampled during the Polarstern cruise ANT XXVII/4 from Capetown to Bremerhaven in spring 2011. GLY and MGLY were determined in the sea surface microlayer (SML) of the ocean and corresponding bulk water (BW) with average concentrations of 228 ng L-1 (GLY) and 196 ng L-1 (MGLY). The results show a significant enrichment (factor of 4) of GLY and MGLY in the SML. Furthermore, marine aerosol particles (PM1) were sampled during the cruise and analyzed for GLY (average concentration 0.19 ng m-3) and MGLY (average concentration 0.15 ng m-3). On aerosol particles, both carbonyls show a very good correlation with oxalate, supporting the idea of a secondary formation of oxalic acid via GLY and MGLY. Concentrations of GLY and MGLY in seawater and on aerosol particles were correlated to environmental parameters such as global radiation, temperature, distance to the coastline and biological activity. There are slight hints for a photochemical production of GLY and MGLY in the SML (significant enrichment in the SML, higher enrichment at higher temperature). However, a clear connection of GLY and MGLY to global radiation as well as to biological activity cannot be concluded from the data. A slight correlation between GLY and MGLY in the SML and in aerosol particles could be a hint for interactions, in particular of GLY, between seawater and the atmosphere.

  5. Bulk Heterojunction Solar Cell with Nitrogen-Doped Carbon Nanotubes in the Active Layer: Effect of Nanocomposite Synthesis Technique on Photovoltaic Properties

    PubMed Central

    Keru, Godfrey; Ndungu, Patrick G.; Mola, Genene T.; Nyamori, Vincent O.

    2015-01-01

    Nanocomposites of poly(3-hexylthiophene) (P3HT) and nitrogen-doped carbon nanotubes (N-CNTs) have been synthesized by two methods; specifically, direct solution mixing and in situ polymerization. The nanocomposites were characterized by means of transmission electron microscopy (TEM), scanning electron microscopy (SEM), X-ray dispersive spectroscopy, UV-Vis spectrophotometry, photoluminescence spectrophotometry (PL), Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, thermogravimetric analysis, and dispersive surface energy analysis. The nanocomposites were used in the active layer of a bulk heterojunction organic solar cell with the composition ITO/PEDOT:PSS/P3HT:N-CNTS:PCBM/LiF/Al. TEM and SEM analysis showed that the polymer successfully wrapped the N-CNTs. FTIR results indicated good π-π interaction within the nanocomposite synthesized by in situ polymerization as opposed to samples made by direct solution mixing. Dispersive surface energies of the N-CNTs and nanocomposites supported the fact that polymer covered the N-CNTs well. J-V analysis show that good devices were formed from the two nanocomposites, however, the in situ polymerization nanocomposite showed better photovoltaic characteristics.

  6. Slope And Equation of Line: Teach And Analysis In Terms of Emotional Intelligence

    NASA Astrophysics Data System (ADS)

    Dewi, A. C.; Budiyono; Riyadi

    2017-09-01

    Slope and equation of line is a sub-material of algebra and is one that is difficult for students to understand. The purpose of this study is to understand and explore the slope and equation so that students feel easy and ultimately improve their academic achievement. Experimental research was conducted by applying Jigsaw II learning model and Teams Games Tournament (TGT) and improvement in emotional intelligence (EI). The study sample was students from 3 different schools who were selected stratified cluster random sampling. The results showed that there is no influence of learning model and EI on academic achievement. This can happen even in the learning process students feel happy and interest. Although research shows different results with most theories, but it is expected that this research can be a good reference for students, teachers, and other researchers.

  7. Optically stimulated luminescence of natural NaCl mineral from Dead Sea exposed to gamma radiation.

    PubMed

    Roman-Lopez, J; Piña López, Y I; Cruz-Zaragoza, E; Marcazzó, J

    2018-08-01

    In this work, the continuous wave - optically stimulated luminescence (CW-OSL) emissions of natural salt minerals, collected from Dead Sea in summer of 2015, were studied. The CW-OSL dose response of natural salt showed a linear range between 0.5Gy and 10Gy of gamma radiation of 60 Co. Samples exposed at 3Gy exhibited good repeatability with a variation coefficient of 4.6%. The CW-OSL response as function of the preheating temperature (50-250°C) was analyzed. An increase of 15% of the CW-OSL response was observed in NaCl samples during storage period of 336h. The results showed that the natural Dead Sea salt minerals could be applied as natural dosimeter of gamma radiation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Measurement of trace nitrate concentrations in seawater by ion chromatography with valve switching

    NASA Astrophysics Data System (ADS)

    Du, Juan; Fa, Yun; Zheng, Yue; Li, Xuebing; Du, Fanglin; Yang, Haiyan

    2014-05-01

    An ion chromatographic method with a valve switching facility was developed to determine trace nitrate concentrations in seawater using two pumps, two different suppressors, and two columns. A carbohydrate membrane desalter was used to reduce the high concentrations of sodium salts in samples. In this method, trace nitrate was eluted from the concentrator column to the analytical columns, while the matrix fl owed to waste. Neither chemical pre-treatment nor sample dilution was required. In the optimized separation conditions, the method showed good linearity ( R >0.99) in the 0.05 and 50 mg/L concentration range, and satisfactory repeatability (RSD<5%, n =6). The limit of detection for nitrate was 0.02 mg/L. Results showed that the valve switching system was suitable and practical for the determination of trace nitrate in seawater.

  9. Two-phase working fluids for the temperature range of 50 to 350 deg, phase 2

    NASA Technical Reports Server (NTRS)

    Saaski, E. W.; Hartl, J. H.

    1980-01-01

    Several two phase heat transfer fluids were tested in aluminum and carbon steel reflux capsules for over 25,000 hours at temperatures up to 300 C. Several fluids showed very good stability and would be useful for long duration heat transfer applications over the range 100 to 350 C. Instrumentation for the measurement of surface tension and viscosity were constructed for use with heat transfer fluids over the temperature range 0 to 300 C and with pressures from 0 to 10 atmospheres. The surface tension measuring device constructed requires less than a 1.0 cc sample and displays an accuracy of about 5 percent in preliminary tests, while the viscometer constructed for this program requires a 0.05 cc sample and shows an accuracy of about 5 percent in initial tests.

  10. Development of a new multi-residue laser diode thermal desorption atmospheric pressure chemical ionization tandem mass spectrometry method for the detection and quantification of pesticides and pharmaceuticals in wastewater samples.

    PubMed

    Boisvert, Michel; Fayad, Paul B; Sauvé, Sébastien

    2012-11-19

    A new solid phase extraction (SPE) method coupled to a high throughput sample analysis technique was developed for the simultaneous determination of nine selected emerging contaminants in wastewater (atrazine, desethylatrazine, 17β-estradiol, ethynylestradiol, norethindrone, caffeine, carbamazepine, diclofenac and sulfamethoxazole). We specifically included pharmaceutical compounds from multiple therapeutic classes, as well as pesticides. Sample pre-concentration and clean-up was performed using a mixed-mode SPE cartridge (Strata ABW) having both cation and anion exchange properties, followed by analysis by laser diode thermal desorption atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). The LDTD interface is a new high-throughput sample introduction method, which reduces total analysis time to less than 15s per sample as compared to minutes with traditional liquid-chromatography coupled to tandem mass spectrometry (LC-MS/MS). Several SPE parameters were evaluated in order to optimize recovery efficiencies when extracting analytes from wastewater, such as the nature of the stationary phase, the loading flow rate, the extraction pH, the volume and composition of the washing solution and the initial sample volume. The method was successfully applied to real wastewater samples from the primary sedimentation tank of a municipal wastewater treatment plant. Recoveries of target compounds from wastewater ranged from 78% to 106%, the limit of detection ranged from 30 to 122ng L(-1) while the limit of quantification ranged from 90 to 370ng L(-1). Calibration curves in the wastewater matrix showed good linearity (R(2)≥0.991) for all target analytes and the intraday and interday coefficient of variation was below 15%, reflecting a good precision. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Estimation of pyrethroid pesticide intake using regression ...

    EPA Pesticide Factsheets

    Population-based estimates of pesticide intake are needed to characterize exposure for particular demographic groups based on their dietary behaviors. Regression modeling performed on measurements of selected pesticides in composited duplicate diet samples allowed (1) estimation of pesticide intakes for a defined demographic community, and (2) comparison of dietary pesticide intakes between the composite and individual samples. Extant databases were useful for assigning individual samples to composites, but they could not provide the breadth of information needed to facilitate measurable levels in every composite. Composite sample measurements were found to be good predictors of pyrethroid pesticide levels in their individual sample constituents where sufficient measurements are available above the method detection limit. Statistical inference shows little evidence of differences between individual and composite measurements and suggests that regression modeling of food groups based on composite dietary samples may provide an effective tool for estimating dietary pesticide intake for a defined population. The research presented in the journal article will improve community's ability to determine exposures through the dietary route with a less burdensome and costly method.

  12. Determination of sulphur in various vegetables by solid sampling high-resolution electrothermal molecular absorption spectrometry.

    PubMed

    Gunduz, Sema; Akman, Suleyman

    2015-04-01

    Sulphur was determined in various vegetables via molecular absorption of carbon monosulphide (CS) at 258.056 nm using a solid sampling high resolution continuum source electrothermal atomic absorption spectrometer (SS HR-CS ETAAS). Samples were dried, ground and directly introduced into the ruthenium coated graphite furnace as 0.05 to 0.50mg. All determinations were performed using palladium+citric acid modifier and applying a pyrolysis temperature of 1000 °C and a volatilisation temperature of 2400 °C. The results were in good agreement with certified sulphur concentrations of various vegetal CRM samples applying linear calibration technique prepared from thioacetamide. The limit of detection and characteristic mass of the method were 7.5 and 8.7 ng of S, respectively. The concentrations of S in various spinach, leek, lettuce, radish, Brussels sprouts, zucchini and chard samples were determined. It was showed that distribution of sulphur in CRM and grinded food samples were homogeneous even in micro-scale. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Resonance Shift of Single-Axis Acoustic Levitation

    NASA Astrophysics Data System (ADS)

    Xie, Wen-Jun; Wei, Bing-Bo

    2007-01-01

    The resonance shift due to the presence and movement of a rigid spherical sample in a single-axis acoustic levitator is studied with the boundary element method on the basis of a two-cylinder model of the levitator. The introduction of a sample into the sound pressure nodes, where it is usually levitated, reduces the resonant interval Hn (n is the mode number) between the reflector and emitter. The larger the sample radius, the greater the resonance shift. When the sample moves along the symmetric axis, the resonance interval Hn varies in an approximately periodical manner, which reaches the minima near the pressure nodes and the maxima near the pressure antinodes. This suggests a resonance interval oscillation around its minimum if the stably levitated sample is slightly perturbed. The dependence of the resonance shift on the sample radius R and position h for the single-axis acoustic levitator is compared with Leung's theory for a closed rectangular chamber, which shows a good agreement.

  14. Self-sampling for human papillomavirus DNA detection: a preliminary study of compliance and feasibility in BOLIVIA.

    PubMed

    Surriabre, Pedro; Allende, Gustavo; Prado, Marcela; Cáceres, Leyddy; Bellot, Diego; Torrico, Andrea; Ustariz, Karina; Rojas, Shirley; Barriga, Jaime; Calle, Pamela; Villarroel, Ligia; Yañez, Rosse Mary; Baay, Marc; Rodriguez, Patricia; Fontaine, Véronique

    2017-12-22

    Cervical cancer incidence and mortality rates in Bolivia are among the highest in Latin America. This investigation aims to evaluate the possibility of using simple devices, e.g. a cotton swab and a glass slide, for self-sampling in order to detect human papillomavirus (HPV) DNA by PCR in cervico-vaginal cells. In the first phase of our study we evaluated the use of a glass slide as a transport medium for cervical cells. A physician took paired-cervical samples from 235 women. One sample was transported in Easyfix® solution and the other sample was smeared over a glass slide. Both were further analyzed and compared for human DNA recovery and HPV detection. A kappa value was determined to evaluate the agreement between the HPV DNA detection rates. In the second phase of the study, 222 women from the urban, peri-urban and rural regions of Cochabamba were requested to perform self-sampling using the following devices: a cotton swab combined with a glass slide, and a vaginal tampon. Women gave their opinion about the self-sampling technique. Finally, the agreement for high risk-HPV detection between self- and physician-collected samples was performed in 201 samples in order to evaluate the self-sampling technique. Firstly, the comparison between Easyfix® solution and the glass slide to transport clinical samples gave a good agreement for HPV DNA detection (κ = 0.71, 95% CI 0.60-0.81). Secondly, self-sampling, especially with cotton swab combined with glass slide, would generally be preferred over clinician sampling for a screening program based on HPV detection. Finally, we showed a good agreement between self- and physician collected samples for high risk-HPV detection (κ = 0.71, 95% CI 0.55-0.88). Simple devices such as a cotton swab and a glass slide can be used to perform self-sampling and HPV DNA detection. Furthermore, most Bolivian women preferred self-sampling over clinician-sampling for cervical cancer screening.

  15. Universal multiplex PCR and CE for quantification of SMN1/SMN2 genes in spinal muscular atrophy.

    PubMed

    Wang, Chun-Chi; Chang, Jan-Gowth; Jong, Yuh-Jyh; Wu, Shou-Mei

    2009-04-01

    We established a universal multiplex PCR and CE to calculate the copy number of survival motor neuron (SMN1 and SMN2) genes for clinical screening of spinal muscular atrophy (SMA). In this study, one universal fluorescent primer was designed and applied for multiplex PCR of SMN1, SMN2 and two internal standards (CYBB and KRIT1). These amplicons were separated by conformation sensitive CE. Mixture of hydroxyethyl cellulose and hydroxypropyl cellulose were used in this CE system. Our method provided the potential to separate two 390-bp PCR products that differ in a single nucleotide. Differentiation and quantification of SMN1 and SMN2 are essential for clinical screening of SMA patients and carriers. The DNA samples included 22 SMA patients, 45 parents of SMA patients (obligatory carriers) and 217 controls. For evaluating accuracy, those 284 samples were blind-analyzed by this method and denaturing high pressure liquid chromatography (DHPLC). Eight of the total samples showed different results. Among them, two samples were diagnosed as having only SMN2 gene by DHPLC, however, they contained both SMN1 and SMN2 by our method. They were further confirmed by DNA sequencing. Our method showed good agreement with the DNA sequencing. The multiplex ligation-dependent probe amplification (MLPA) was used for confirming the other five samples, and showed the same results with our CE method. For only one sample, our CE showed different results with MLPA and DNA sequencing. One out of 284 samples (0.35%) belonged to mismatching. Our method provided a better accurate method and convenient method for clinical genotyping of SMA disease.

  16. Bispolides, novel 20-membered ring macrodiolide antibiotics from microbispora.

    PubMed

    Okujo, Noriyuki; Iinuma, Hironobu; George, Annie; Eim, Khor Siew; Li, Tan Lee; Ting, Ng Szu; Jye, Tan Chin; Hotta, Kunimoto; Hatsu, Masahiro; Fukagawa, Yasuo; Shibahara, Seiji; Numata, Keiichi; Kondo, Shinichi

    2007-03-01

    Seven new related compounds named bispolides A1, A2, A3, B1, B2a, B2b and B3, have been found in a culture of Microbispora sp. A34030, isolated from a Malaysian soil sample. The planar structures were elucidated to be new 20-membered ring macrodiolide antibiotics on the basis of MS and NMR spectroscopic analyses. These antibiotics showed a good anti-MRSA activity in vitro.

  17. Translations on Environmental Quality, Number 150

    DTIC Science & Technology

    1977-10-17

    again and again.... I recently did some calculations and it turned out that in 10 years the supplementary pay for those sick, the costs of treatment ...They required hospital treatment for a month and a half and 3 weeks respectively. At the Pal Heim Hospital "We have treated three small children...instruments showed an accumula- tion of lead in urine samples. After treatment , we released them in good condition. We received another three children during

  18. Use of Multiple Displacement Amplification as Pre-polymerase Chain Reaction (Pre-PCR) to amplify genomic DNA of siphonapterids preserved for long periods in scientific collections.

    PubMed

    Avelar, Daniel M; Linardi, Pedro M

    2010-09-15

    The recently developed Multiple Displacement Amplification technique (MDA) allows for the production of a large quantity of high quality genomic DNA from low amounts of the original DNA. The goal of this study was to evaluate the performance of the MDA technique to amplify genomic DNA of siphonapterids that have been stored for long periods in 70% ethanol at room temperature. We subjected each DNA sample to two different methodologies: (1) amplification of mitochondrial 16S sequences without MDA; (2) amplification of 16S after MDA. All the samples obtained from these procedures were then sequenced. Only 4 samples (15.4%) subjected to method 1 showed amplification. In contrast, the application of MDA (method 2) improved the performance substantially, with 24 samples (92.3%) showing amplification, with significant difference. Interestingly, one of the samples successfully amplified with this method was originally collected in 1909. All of the sequenced samples displayed satisfactory results in quality evaluations (Phred ≥ 20) and good similarities, as identified with the BLASTn tool. Our results demonstrate that the use of MDA may be an effective tool in molecular studies involving specimens of fleas that have traditionally been considered inadequately preserved for such purposes.

  19. Use of Multiple Displacement Amplification as Pre-polymerase Chain Reaction (Pre-PCR) to amplify genomic DNA of siphonapterids preserved for long periods in scientific collections

    PubMed Central

    2010-01-01

    The recently developed Multiple Displacement Amplification technique (MDA) allows for the production of a large quantity of high quality genomic DNA from low amounts of the original DNA. The goal of this study was to evaluate the performance of the MDA technique to amplify genomic DNA of siphonapterids that have been stored for long periods in 70% ethanol at room temperature. We subjected each DNA sample to two different methodologies: (1) amplification of mitochondrial 16S sequences without MDA; (2) amplification of 16S after MDA. All the samples obtained from these procedures were then sequenced. Only 4 samples (15.4%) subjected to method 1 showed amplification. In contrast, the application of MDA (method 2) improved the performance substantially, with 24 samples (92.3%) showing amplification, with significant difference. Interestingly, one of the samples successfully amplified with this method was originally collected in 1909. All of the sequenced samples displayed satisfactory results in quality evaluations (Phred ≥ 20) and good similarities, as identified with the BLASTn tool. Our results demonstrate that the use of MDA may be an effective tool in molecular studies involving specimens of fleas that have traditionally been considered inadequately preserved for such purposes. PMID:20840790

  20. Process development and characterization of centrosymmetric semiorganic nonlinear optical crystal: 4-dimethylaminopyridine potassium chloride

    NASA Astrophysics Data System (ADS)

    Johnson, J.; Srineevasan, R.; Sivavishnu, D.

    2018-06-01

    Centrosymmetric semiorganic crystal 4-dimethylaminopyridine potassium chloride (4-DMAPKC) has been grown successfully by using slow evaporation solution growth technique. Powder x-ray diffraction shows the 4-DMAPKC crystal has good crystalline nature. Single crystal XRD shows that the grown 4-DMAPKC is cubic crystal system with cell parameters a = 3.09 Å, b = 3.09 Å, c = 3.09 Å. Investigation has been carried out to assign the Vibrational frequencies of the grown crystal by FTIR spectral studies. UVsbnd Visible NIR optical absorption spectral studies in the range of 200-1100 nm shows low absorption in UVsbnd Visible region with lower cutoff wave length at 261 nm and optical band gap energy was found as Eg = 5.52 eV. Optically transmittance spectral shows 4-DMAPKC crystal is very good transparency in UV-Visible NIR region. Thermogravimetry and differential thermal (TG-DTA) analysis were carried out. Dielectric studies of as grown crystal sample exhibit low dielectric constant and loss at higher frequencies and attests the nonlinear optical activity. Micro hardness studies of as grown crystal were discussed. Second harmonic generation (SHG) efficiency of the 4-DMAPKC is 0.69 times as that of KDP.

  1. Psychometric evaluation of the Swedish version of Rosenberg's self-esteem scale.

    PubMed

    Eklund, Mona; Bäckström, Martin; Hansson, Lars

    2018-04-01

    The widely used Rosenberg's self-esteem scale (RSES) has not been evaluated for psychometric properties in Sweden. This study aimed at analyzing its factor structure, internal consistency, criterion, convergent and discriminant validity, sensitivity to change, and whether a four-graded Likert-type response scale increased its reliability and validity compared to a yes/no response scale. People with mental illness participating in intervention studies to (1) promote everyday life balance (N = 223) or (2) remedy self-stigma (N = 103) were included. Both samples completed the RSES and questionnaires addressing quality of life and sociodemographic data. Sample 1 also completed instruments chosen to assess convergent and discriminant validity: self-mastery (convergent validity), level of functioning and occupational engagement (discriminant validity). Confirmatory factor analysis (CFA), structural equation modeling, and conventional inferential statistics were used. Based on both samples, the Swedish RSES formed one factor and exhibited high internal consistency (>0.90). The two response scales were equivalent. Criterion validity in relation to quality of life was demonstrated. RSES could distinguish between women and men (women scoring lower) and between diagnostic groups (people with depression scoring lower). Correlations >0.5 with variables chosen to reflect convergent validity and around 0.2 with variables used to address discriminant validity further highlighted the construct validity of RSES. The instrument also showed sensitivity to change. The Swedish RSES exhibited a one-component factor structure and showed good psychometric properties in terms of good internal consistency, criterion, convergent and discriminant validity, and sensitivity to change. The yes/no and the four-graded Likert-type response scales worked equivalently.

  2. Abdominal fat volume estimation by stereology on CT: a comparison with manual planimetry.

    PubMed

    Manios, G E; Mazonakis, M; Voulgaris, C; Karantanas, A; Damilakis, J

    2016-03-01

    To deploy and evaluate a stereological point-counting technique on abdominal CT for the estimation of visceral (VAF) and subcutaneous abdominal fat (SAF) volumes. Stereological volume estimations based on point counting and systematic sampling were performed on images from 14 consecutive patients who had undergone abdominal CT. For the optimization of the method, five sampling intensities in combination with 100 and 200 points were tested. The optimum stereological measurements were compared with VAF and SAF volumes derived by the standard technique of manual planimetry on the same scans. Optimization analysis showed that the selection of 200 points along with the sampling intensity 1/8 provided efficient volume estimations in less than 4 min for VAF and SAF together. The optimized stereology showed strong correlation with planimetry (VAF: r = 0.98; SAF: r = 0.98). No statistical differences were found between the two methods (VAF: P = 0.81; SAF: P = 0.83). The 95% limits of agreement were also acceptable (VAF: -16.5%, 16.1%; SAF: -10.8%, 10.7%) and the repeatability of stereology was good (VAF: CV = 4.5%, SAF: CV = 3.2%). Stereology may be successfully applied to CT images for the efficient estimation of abdominal fat volume and may constitute a good alternative to the conventional planimetric technique. Abdominal obesity is associated with increased risk of disease and mortality. Stereology may quantify visceral and subcutaneous abdominal fat accurately and consistently. The application of stereology to estimating abdominal volume fat reduces processing time. Stereology is an efficient alternative method for estimating abdominal fat volume.

  3. Validation of the German version of the insomnia severity index in adolescents, young adults and adult workers: results from three cross-sectional studies.

    PubMed

    Gerber, Markus; Lang, Christin; Lemola, Sakari; Colledge, Flora; Kalak, Nadeem; Holsboer-Trachsler, Edith; Pühse, Uwe; Brand, Serge

    2016-05-31

    A variety of objective and subjective methods exist to assess insomnia. The Insomnia Severity Index (ISI) was developed to provide a brief self-report instrument useful to assess people's perception of sleep complaints. The ISI was developed in English, and has been translated into several languages including German. Surprisingly, the psychometric properties of the German version have not been evaluated, although the ISI is often used with German-speaking populations. The psychometric properties of the ISI are tested in three independent samples: 1475 adolescents, 862 university students, and 533 police and emergency response service officers. In all three studies, participants provide information about insomnia (ISI), sleep quality (Pittsburgh Sleep Quality Index), and psychological functioning (diverse instruments). Descriptive statistics, gender differences, homogeneity and internal consistency, convergent validity, and factorial validity (including measurement invariance across genders) are examined in each sample. The findings show that the German version of the ISI has generally acceptable psychometric properties and sufficient concurrent validity. Confirmatory factor analyses show that a 1-factor solution achieves good model fit. Furthermore, measurement invariance across gender is supported in all three samples. While the ISI has been widely used in German-speaking countries, this study is the first to provide empirical evidence that the German version of this instrument has good psychometric properties and satisfactory convergent and factorial validity across various age groups and both men and women. Thus, the German version of the ISI can be recommended as a brief screening measure in German-speaking populations.

  4. Development of an improved sample preparation platform for acidic endogenous hormones in plant tissues using electromembrane extraction.

    PubMed

    Suh, Joon Hyuk; Han, Sang Beom; Wang, Yu

    2018-02-02

    Despite their importance in pivotal signaling pathways due to trace quantities and complex matrices, the analysis of plant hormones is a challenge. Here, to improve this issue, we present an electromembrane extraction technology combined with liquid chromatography-tandem mass spectrometry for determination of acidic plant hormones including jasmonic acid, abscisic acid, salicylic acid, benzoic acid, gibberellic acid and gibberellin A 4 in plant tissues. Factors influencing extraction efficiency, such as voltage, extraction time and stirring rate were optimized using a design of experiments. Analytical performance was evaluated in terms of specificity, linearity, limit of quantification, precision, accuracy, recovery and repeatability. The results showed good linearity (r 2  > 0.995), precision and acceptable accuracy. The limit of quantification ranged from 0.1 to 10 ng mL -1 , and the recoveries were 34.6-50.3%. The developed method was applied in citrus leaf samples, showing better clean-up efficiency, as well as higher sensitivity compared to a previous method using liquid-liquid extraction. Organic solvent consumption was minimized during the process, making it an appealing method. More noteworthy, electromembrane extraction has been scarcely applied to plant tissues, and this is the first time that major plant hormones were extracted using this technology, with high sensitivity and selectivity. Taken together, this work gives not only a novel sample preparation platform using an electric field for plant hormones, but also a good example of extracting complex plant tissues in a simple and effective way. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. [Spanish validation of the Boston Carpal Tunnel Questionnaire].

    PubMed

    Oteo-Álvaro, Ángel; Marín, María T; Matas, José A; Vaquero, Javier

    2016-03-18

    To describe the process of cultural adaptation and validation of the Boston Carpal Tunnel Questionnaire (BCTQ) measuring symptom intensity, functional status and quality of life in carpal tunnel syndrome patients and to report the psychometric properties of this version. A 3 expert panel supervised the adaptation process. After translation, review and back-translation of the original instrument, a new Spanish version was obtained, which was administered to 2 patient samples: a pilot sample of 20 patients for assessing comprehension, and a 90 patient sample for assessing structural validity (factor analysis and reliability), construct validity and sensitivity to change. A re-test measurement was carried out in 21 patients. Follow-up was accomplished in 40 patients. The questionnaire was well accepted by all participants. Celling effect was observed for 3 items. Reliability was very good, internal consistency: αS=0.91 y αF=0.87; test-retest stability: rS=0.939 and rF=0.986. Both subscales fitted to a general dimension. Subscales correlated with dynamometer measurements (rS=0.77 and rF=0.75) and showed to be related to abnormal 2-point discrimination, muscle atrophy and electromyography deterioration level. Scores properly correlated with other validated instruments: Douleur Neuropatique 4 questions and Brief Pain Inventory. BCTQ demonstrated to be sensitive to clinical changes, with large effect sizes (dS=-3.3 and dF=-1.9). The Spanish version of the BCTQ shows good psychometric properties warranting its use in clinical settings. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  6. Syndromes of Self-Reported Psychopathology for Ages 18-59 in 29 Societies.

    PubMed

    Ivanova, Masha Y; Achenbach, Thomas M; Rescorla, Leslie A; Tumer, Lori V; Ahmeti-Pronaj, Adelina; Au, Alma; Maese, Carmen Avila; Bellina, Monica; Caldas, J Carlos; Chen, Yi-Chuen; Csemy, Ladislav; da Rocha, Marina M; Decoster, Jeroen; Dobrean, Anca; Ezpeleta, Lourdes; Fontaine, Johnny R J; Funabiki, Yasuko; Guðmundsson, Halldór S; Harder, Valerie S; de la Cabada, Marie Leiner; Leung, Patrick; Liu, Jianghong; Mahr, Safia; Malykh, Sergey; Maras, Jelena Srdanovic; Markovic, Jasminka; Ndetei, David M; Oh, Kyung Ja; Petot, Jean-Michel; Riad, Geylan; Sakarya, Direnc; Samaniego, Virginia C; Sebre, Sandra; Shahini, Mimoza; Silvares, Edwiges; Simulioniene, Roma; Sokoli, Elvisa; Talcott, Joel B; Vazquez, Natalia; Zasepa, Ewa

    2015-06-01

    This study tested the multi-society generalizability of an eight-syndrome assessment model derived from factor analyses of American adults' self-ratings of 120 behavioral, emotional, and social problems. The Adult Self-Report (ASR; Achenbach and Rescorla 2003) was completed by 17,152 18-59-year-olds in 29 societies. Confirmatory factor analyses tested the fit of self-ratings in each sample to the eight-syndrome model. The primary model fit index (Root Mean Square Error of Approximation) showed good model fit for all samples, while secondary indices showed acceptable to good fit. Only 5 (0.06%) of the 8,598 estimated parameters were outside the admissible parameter space. Confidence intervals indicated that sampling fluctuations could account for the deviant parameters. Results thus supported the tested model in societies differing widely in social, political, and economic systems, languages, ethnicities, religions, and geographical regions. Although other items, societies, and analytic methods might yield different results, the findings indicate that adults in very diverse societies were willing and able to rate themselves on the same standardized set of 120 problem items. Moreover, their self-ratings fit an eight-syndrome model previously derived from self-ratings by American adults. The support for the statistically derived syndrome model is consistent with previous findings for parent, teacher, and self-ratings of 1½-18-year-olds in many societies. The ASR and its parallel collateral-report instrument, the Adult Behavior Checklist (ABCL), may offer mental health professionals practical tools for the multi-informant assessment of clinical constructs of adult psychopathology that appear to be meaningful across diverse societies.

  7. Enantioselective piezoelectric quartz crystal sensor for d-methamphetamine based on a molecularly imprinted polymer.

    PubMed

    Arenas, Leveriza F; Ebarvia, Benilda S; Sevilla, Fortunato B

    2010-08-01

    A piezoelectric quartz crystal (PQC) sensor based on a molecularly imprinted polymer (MIP) has been developed for enantioselective and quantitative analysis of d-(+)-methamphetamine (d(+)-MA). The sensor was produced by bulk polymerization and the resulting MIP was then coated on the gold electrode of an AT-cut quartz crystal. Conditions such as volume of polymer coating, curing time, type of PQC, baseline solvent, pH, and buffer type were found to affect the sensor response and were therefore optimized. The PQC-MIP gave a stable response to different concentrations of d(+)-MA standard solutions (response time = 10 to 100 s) with good repeatability (RSD = 0.03 to 3.09%; n = 3), good reproducibility (RSD = 3.55%; n = 5), and good reversibility (RSD = 0.36%; n = 3). The linear range of the sensor covered five orders of magnitude of analyte concentration, ranging from 10(-5) to 10(-1) microg mL(-1), and the limit of detection was calculated as 11.9 pg d(+)-MA mL(-1) . The sensor had a highly enantioselective response to d(+)-MA compared with its response to l(-)-MA, racemic MA, and phentermine. The developed sensor was validated by applying it to human urine samples from drug-free individuals spiked with standard d(+)-MA and from a confirmed MA user. Use of the standard addition method (SAM) and samples spiked with d(+)-MA at levels ranging from 1 x 10(-3) to 1 x 10(-2) microg mL(-1) showed recovery was good (95.3 to 110.9%).

  8. Comparative performance of conventional OPC concrete and HPC designed by densified mixture design algorithm

    NASA Astrophysics Data System (ADS)

    Huynh, Trong-Phuoc; Hwang, Chao-Lung; Yang, Shu-Ti

    2017-12-01

    This experimental study evaluated the performance of normal ordinary Portland cement (OPC) concrete and high-performance concrete (HPC) that were designed by the conventional method (ACI) and densified mixture design algorithm (DMDA) method, respectively. Engineering properties and durability performance of both the OPC and HPC samples were studied using the tests of workability, compressive strength, water absorption, ultrasonic pulse velocity, and electrical surface resistivity. Test results show that the HPC performed good fresh property and further showed better performance in terms of strength and durability as compared to the OPC.

  9. High-throughput quantitative analysis by desorption electrospray ionization mass spectrometry.

    PubMed

    Manicke, Nicholas E; Kistler, Thomas; Ifa, Demian R; Cooks, R Graham; Ouyang, Zheng

    2009-02-01

    A newly developed high-throughput desorption electrospray ionization (DESI) source was characterized in terms of its performance in quantitative analysis. A 96-sample array, containing pharmaceuticals in various matrices, was analyzed in a single run with a total analysis time of 3 min. These solution-phase samples were examined from a hydrophobic PTFE ink printed on glass. The quantitative accuracy, precision, and limit of detection (LOD) were characterized. Chemical background-free samples of propranolol (PRN) with PRN-d(7) as internal standard (IS) and carbamazepine (CBZ) with CBZ-d(10) as IS were examined. So were two other sample sets consisting of PRN/PRN-d(7) at varying concentration in a biological milieu of 10% urine or porcine brain total lipid extract, total lipid concentration 250 ng/microL. The background-free samples, examined in a total analysis time of 1.5 s/sample, showed good quantitative accuracy and precision, with a relative error (RE) and relative standard deviation (RSD) generally less than 3% and 5%, respectively. The samples in urine and the lipid extract required a longer analysis time (2.5 s/sample) and showed RSD values of around 10% for the samples in urine and 4% for the lipid extract samples and RE values of less than 3% for both sets. The LOD for PRN and CBZ when analyzed without chemical background was 10 and 30 fmol, respectively. The LOD of PRN increased to 400 fmol analyzed in 10% urine, and 200 fmol when analyzed in the brain lipid extract.

  10. Physico-chemical analysis and antimicrobial potential of Apis dorsata, Apis mellifera and Ziziphus jujube honey samples from Pakistan

    PubMed Central

    Fahim, Hira; Dasti, Javid Iqbal; Ali, Ihsan; Ahmed, Safia; Nadeem, Muhammad

    2014-01-01

    Objective To evaluate physico-chemical properties and antimicrobial potential of indigenous honey samples against different reference strains including Escherichia coli ATCC 8739, Enterobacter aerogenes ATCC 13048, Pseudomonas aeroginosa ATCC 9027, Bacillus subtilis ATCC 6633, Staphylococcus aureus ATCC 25923, Salmonella typhi ATCC 14028, Klebsiella pneumonia ATCC 13883, Aspergillus niger ATCC 16404, Rhizopus oligosporus PCSIR1, Candida albicans ATCC 14053 and Candida utilis ATCC 9950. Methods By using standard methods samples were evaluated for their antimicrobial properties including additive effect of starch and non-peroxidase activity, antioxidative properties (phenol contents, flavonoid contents, 1,1-diphenyl-2-picrylhydrazyl radical scavenging activity). Prior to this evaluation, complete physico-chemical properties including pH, color, ash contents, protein contents, moisture contents, hydroxymethyl furfural contents, total sugar contents, reducing sugar and non-reducing sugar contents were analyzed. Results Relatively higher ash contents were found in the Siddar honey i.e. (0.590 0±0.033 6)% and small honey showed relatively higher protein contents i.e. (777.598±9.880) mg/kg. The moisture contents of tested honey samples ranged between 13.8%-16.6%, total sugar contents from 61.672%-72.420% and non-reducing sugar contents from 1.95%-3.93%. Presences of phenolic contents indicate higher antioxidant potential of these honey samples. All bacteria showed clear inhibition zones in response to tested honey samples whereas fungi and yeast showed inhibition at higher concentrations of these honey samples. For Escherichia coli, Bacillus subtilis, Salmonella typhi, Pseudomonas aeroginosa and Aspergillus niger, overall the small honey showed the higher activity than other honey samples. Conclusion Physico-chemical analysis of honey samples confirmed good quality of honey according to the standards set by European Union Commission and Codex Alimentarius Commission. Evaluation of these honey samples confirms antimicrobial potential of particular types of honeys indigenous to Pakistan. PMID:25183333

  11. Interlaboratory Comparison of Magnetic Thin Film Measurements.

    PubMed

    da Silva, F C S; Wang, C M; Pappas, D P

    2003-01-01

    A potential low magnetic moment standard reference material (SRM) was studied in an interlaboratory comparison. The mean and the standard deviation of the saturation moment m s, the remanent moment m r, and the intrinsic coercivity H c of nine samples were extracted from hysteresis-loop measurements. Samples were measured by thirteen laboratories using inductive-field loopers, vibrating-sample magnetometers, alternating-gradient force magnetometers, and superconducting quantum-interference-device magnetometers. NiFe films on Si substrates had saturation moment measurements reproduced within 5 % variation among the laboratories. The results show that a good candidate for an SRM must have a highly square hysteresis loop (m r/m s > 90 %), H c ≈ 400 A·m(-1) (5 Oe), and m s ≈ 2 × 10(-7) A·m(2) (2 × 10(-4) emu).

  12. Reconnaissance of Pharmaceutical Chemicals in Urban Streams of the Tualatin River Basin, Oregon, 2002

    USGS Publications Warehouse

    Rounds, Stewart A.; Doyle, Micelis C.; Edwards, Patrick M.; Furlong, Edward T.

    2009-01-01

    A reconnaissance of pharmaceutical chemicals in urban streams of the Tualatin River basin was conducted in July 2002 in an effort to better understand the occurrence and distribution of such compounds, and to determine whether they might be useful indicators of human-related stream contamination. Of the 21 pharmaceutical chemicals and metabolites tested, only 6 (acetaminophen, caffeine, carbamazepine, codeine, cotinine, and sulfamethoxazole) were detected in filtered stream samples from 10 sites. The concentrations of most of the detected compounds were relatively low (less than 0.05 microgram per liter). The most frequently detected compounds were cotinine (a nicotine metabolite, 8 of 10 samples) and caffeine (a stimulant, 7 of 10 samples). More compounds were detected in urban stream samples than in samples from forested or agricultural drainages. Filtered water samples also were collected from four locations within an advanced wastewater treatment facility to quantify the relative amounts of these chemicals in a municipal waste stream and to determine the degree to which those chemicals are removed by treatment processes. Fifteen pharmaceutical chemicals or metabolites were detected in wastewater treatment facility influent, with concentrations far exceeding those measured in streams. Only five of those compounds, however, were detected in the treated effluent (carbamazepine, cotinine, ibuprofen, metformin, and sulfamethoxazole) and most of those were at concentrations less than 0.2 microgram per liter. The target pharmaceutical chemicals and metabolites showed limited potential for use as tracers of specific types of human-related contamination in Tualatin River basin streams because of widespread sources (caffeine, for example) or extremely low concentrations. Caffeine and cotinine are likely to be good indicators of sources that can occur in urban areas, such as sewage spills or leaks or the widespread use and careless disposal of tobacco products and caffeine-containing beverages. Neither compound, however, is likely to be a good tracer for a specific source unless that source is large. The presence of 1,7-dimethylxanthine (a caffeine metabolite) concurrently with caffeine might indicate the presence of untreated wastewater; in contrast, the absence of the metabolite might help rule out that source. Acetaminophen might make a good tracer for untreated wastewater because of its common usage, high concentration in raw wastewater, and effective removal via treatment. Carbamazepine and sulfamethoxazole have the potential to be good indicators of treated wastewater because of their incomplete removal in treatment facilities. Some of these pharmaceutical chemicals, either singly or in combination, might prove useful as tracers of contamination after further study.

  13. Evaluation of process errors in bed load sampling using a Dune Model

    USGS Publications Warehouse

    Gomez, Basil; Troutman, Brent M.

    1997-01-01

    Reliable estimates of the streamwide bed load discharge obtained using sampling devices are dependent upon good at-a-point knowledge across the full width of the channel. Using field data and information derived from a model that describes the geometric features of a dune train in terms of a spatial process observed at a fixed point in time, we show that sampling errors decrease as the number of samples collected increases, and the number of traverses of the channel over which the samples are collected increases. It also is preferable that bed load sampling be conducted at a pace which allows a number of bed forms to pass through the sampling cross section. The situations we analyze and simulate pertain to moderate transport conditions in small rivers. In such circumstances, bed load sampling schemes typically should involve four or five traverses of a river, and the collection of 20–40 samples at a rate of five or six samples per hour. By ensuring that spatial and temporal variability in the transport process is accounted for, such a sampling design reduces both random and systematic errors and hence minimizes the total error involved in the sampling process.

  14. Perceptual and Acoustic Analyses of Good Voice Quality in Male Radio Performers.

    PubMed

    Warhurst, Samantha; Madill, Catherine; McCabe, Patricia; Ternström, Sten; Yiu, Edwin; Heard, Robert

    2017-03-01

    Good voice quality is an asset to professional voice users, including radio performers. We examined whether (1) voices could be reliably categorized as good for the radio and (2) these categories could be predicted using acoustic measures. Male radio performers (n = 24) and age-matched male controls performed "The Rainbow Passage" as if presenting on the radio. Voice samples were rated using a three-stage paired-comparison paradigm by 51 naive listeners and perceptual categories were identified (Study 1), and then analyzed for fundamental frequency, long-term average spectrum, cepstral peak prominence, and pause or spoken-phrase duration (Study 2). Study 1: Good inter-judge reliability was found for perceptual judgments of the best 15 voices (good for radio category, 14/15 = radio performers), but agreement on the remaining 33 voices (unranked category) was poor. Study 2: Discriminant function analyses showed that the SD standard deviation of sounded portion duration, equivalent sound level, and smoothed cepstral peak prominence predicted membership of categories with moderate accuracy (R 2  = 0.328). Radio performers are heterogeneous for voice quality; good voice quality was judged reliably in only 14 out of 24 radio performers. Current acoustic analyses detected some of the relevant signal properties that were salient in these judgments. More refined perceptual analysis and the use of other perceptual methods might provide more information on the complex nature of judging good voices. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  15. Selective extraction based on poly(MAA-VB-EGMDA) monolith followed by HPLC for determination of hordenine in plasma and urine samples.

    PubMed

    Chen, Yonggang; Meng, Junhua; Zou, Jili; An, Jing

    2015-06-01

    Hordenine is an active compound found in several foods, herbs and beer. In this work, a novel sorbent was fabricated for selective solid-phase extraction (SPE) of hordenine in biological samples. The organic polymer sorbent was synthesized in one step in the plastic barrel of a syringe by a pre-polymerization solution consisting of methacrylic acid (MAA), 4-vinylphenylboronic acid (VB) and ethylene glycol dimethacrylate (EGDMA). The conditions for preparation were optimized to generate a poly(MAA-VB-EGMDA) monolith with good permeability. The monolith exhibited good enrichment efficiency towards hordenine. By using tyramine as the internal standard, a poly(MAA-VB-EGMDA)-based SPE-HPLC method was established for analysis of hordenine. Conditions for SPE, including volume of eluting solvent, pH of sample solution, sampling rate and sample volume, were optimized. The proposed SPE-HPLC method presented good linearity (R(2)  = 0.9992) within 10-2000 ng/mL and the detection limits was 3 ng/mL, which is significantly more sensitive than reported methods. The method was also applied in plasma and urine samples; good capability of removing matrices was observed, while hordenine in low content was well extracted and enriched. The recoveries were from 90.6 to 94.7% and from 89.3 to 91.5% for the spiked plasma and urine samples, respectively, with the relative standard deviations <4.7%. Copyright © 2014 John Wiley & Sons, Ltd.

  16. Successful Sampling Strategy Advances Laboratory Studies of NMR Logging in Unconsolidated Aquifers

    NASA Astrophysics Data System (ADS)

    Behroozmand, Ahmad A.; Knight, Rosemary; Müller-Petke, Mike; Auken, Esben; Barfod, Adrian A. S.; Ferré, Ty P. A.; Vilhelmsen, Troels N.; Johnson, Carole D.; Christiansen, Anders V.

    2017-11-01

    The nuclear magnetic resonance (NMR) technique has become popular in groundwater studies because it responds directly to the presence and mobility of water in a porous medium. There is a need to conduct laboratory experiments to aid in the development of NMR hydraulic conductivity models, as is typically done in the petroleum industry. However, the challenge has been obtaining high-quality laboratory samples from unconsolidated aquifers. At a study site in Denmark, we employed sonic drilling, which minimizes the disturbance of the surrounding material, and extracted twelve 7.6 cm diameter samples for laboratory measurements. We present a detailed comparison of the acquired laboratory and logging NMR data. The agreement observed between the laboratory and logging data suggests that the methodologies proposed in this study provide good conditions for studying NMR measurements of unconsolidated near-surface aquifers. Finally, we show how laboratory sample size and condition impact the NMR measurements.

  17. Emission spectrographic determination of volatile trace elements in geologic materials by a carrier distillation technique

    USGS Publications Warehouse

    Barton, H.N.

    1986-01-01

    Trace levels of chalcophile elements that form volatile sulfide minerals are determined in stream sediments and in the nonmagnetic fraction of a heavy-mineral concentrate of stream sediments by a carrier distillation emission spectrographic method. Photographically recorded spectra of samples are visually compared with those of synthetic standards for the two sample types. Rock and soil samples may also be analyzed by comparison with the stream-sediment standards. A gallium oxide spectrochemical carrier/buffer enhances the early emission of the volatile elements. Detection limits in parts per million attained are: Sb 5, As 20, Bi 0.1, Cd 1, Cu 1, Pb 2, Ag 0.1, Zn 2, and Sn 0.1. A comparison with other methods of analysis, total-burn emission and atomic absorption spectroscopy, shows good correlation for standard reference for materials and samples from a variety of geologic terranes. ?? 1986.

  18. Selected papers in the hydrologic sciences 1984; July 1984

    USGS Publications Warehouse

    Meyer, Eric L.

    1984-01-01

    The rapid, accurate measurement of the oxygen content of soil gas in the unsaturated zone or dissolved oxygen in soil water in the saturated zone can be useful in wetland vegetation studies. A method has been devised and tested in the Great Dismal Swamp, a wetland with fine silt-clay and organic soils, that appears to provide good results. A 60-milliliter sample of soil gas or water is withdrawn from permanently installed chambers at various depths in the soil profile. The oxygen concentration of air samples is measured with a specially constructed analyzer cell fitted to the polarographic oxygen electrode of a portable oxygen meter. The dissolved oxygen concentration of water samples is measured directly with the oxygen electrode while stirring the sample in a 32-milliliter glass bottle with a portable magnetic stirrer. Field tests with duplicate chamber installations showed that consistent results are obtained for soil gas and water.

  19. Gamma ray interaction studies of organic nonlinear optical materials in the energy range 122 keV-1330 keV

    NASA Astrophysics Data System (ADS)

    Awasarmol, V. V.; Gaikwad, D. K.; Raut, S. D.; Pawar, P. P.

    The mass attenuation coefficients (μm) for organic nonlinear optical materials measured at 122-1330 keV photon energies were investigated on the basis of mixture rule and compared with obtained values of WinXCOM program. It is observed that there is a good agreement between theoretical and experimental values of the samples. All samples were irradiated with six radioactive sources such as 57Co, 133Ba, 22Na, 137Cs, 54Mn and 60Co using transmission arrangement. Effective atomic and electron numbers or electron densities (Zeff and Neff), molar extinction coefficient (ε), mass energy absorption coefficient (μen/ρ) and effective atomic energy absorption cross section (σa,en) were determined experimentally and theoretically using the obtained μm values for investigated samples and graphs have been plotted. The graph shows that the variation of all samples decreases with increasing photon energy.

  20. Coal desulfurization by a microwave process. Technical progress report, February 1981-May 1981

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zavitsanos, P.D.; Golden, J.A.; Bleiler, K.W.

    1981-01-01

    Desulfurization experiments were carried out using the 6KW, 2450 MHz Flow Reactor System. The program has been directed toward the combination of physical separation and microwave exposure with NaOH to increase sulfur removal. The following treatment sequence has been used with good results: (1) expose 1/4 to 1 in. raw coal to microwaves; (2) crush the treated coal and separate the sample into float/sink fractions; (3) add NaOH to the float fraction and re-expose the sample to microwaves; and (4) wash, add NaOH and expose to microwaves. This procedure has produced up to 89% sulfur removal and as low asmore » 0.31 numberS/10/sup 6/ Btu. Ash analyses on these samples showed as high as 40% reduction. The calorific value was increased in almost all samples. Data on sulfur, ash and calorific values are summarized.« less

  1. Establishment of an evaluation model for human milk fat substitutes.

    PubMed

    Wang, Yong-Hua; Mai, Qing-Yun; Qin, Xiao-Li; Yang, Bo; Wang, Zi-Lian; Chen, Hai-Tian

    2010-01-13

    Fatty acid composition and distribution of human milk fat (HMF), from mothers over different lactating periods in Guangzhou, China, were analyzed. The universal characteristics were consistent with previously reported results although the fatty acid content was within a different range and dependent on the local population (low saturated fatty acid and high oleic acid for Guangdong mothers' milk fat). Based on the composition of the total and sn-2 fatty acids of mature milk fat, an efficient evaluation model was innovatively established by adopting the "deducting score" principle. The model showed good agreement between the scores and the degree of similarity by assessing 15 samples from different sources including four samples of HMF, eight samples of human milk fat substitutes (HMFSs) and infant formulas, and three samples of fats and oils. This study would allow for the devolvement of individual human milk fat substitutes with different and specific fatty acid compositions for local infants.

  2. Analysis of pollen load based on color, physicochemical composition and botanical source.

    PubMed

    Modro, Anna F H; Silva, Izabel C; Luz, Cynthia F P; Message, Dejair

    2009-06-01

    Pollen load samples from 10 hives of Apis mellifera (L.) were analyzed based on their physicochemical composition and botanical source, considering color as a parameter for quality control. In seven samples it was possible to establish the occurrence of more than 80% of a single pollen type, characterizing them as unifloral but with protein content variation. One of the samples was exclusively composed of saprophytic fungi (Cladosporium sp.). Comparing the mean results of the fungi loads with those of the nutritional components of pollen load, the former presented higher protein, mineral matter and dry matter and lower organic matter, ethereal extract and total carbohydrate values. The monochromatic samples met the physicochemical specifications regulating pollen load quality. The results showed that homogeneous coloration of the pollen load was not found to be a good indication of unifloral pollen, confirming the importance of physicochemical analysis and melissopalynological analysis for characterization of the quality of commercial pollen load.

  3. Orthorexia nervosa: validation of a diagnosis questionnaire.

    PubMed

    Donini, L M; Marsili, D; Graziani, M P; Imbriale, M; Cannella, C

    2005-06-01

    To validate a questionnaire for the diagnosis of orhorexia oervosa, an eating disorder defined as "maniacal obsession for healthy food". 525 subjects were enrolled. Then they were randomized into two samples (sample of 404 subjects for the construction of the test for the diagnosis of orthorexia ORTO-15; sample of 121 subjects for the validation of the test). The ORTO-15 questionnaire, validated for the diagnosis of orthorexia, is made-up of 15 multiple-choice items. The test we proposed for the diagnosis of orthorexia (ORTO 15) showed a good predictive capability at a threshold value of 40 (efficacy 73.8%, sensitivity 55.6% and specificity 75.8%) also on verification with a control sample. However, it has a limit in identifying the obsessive disorder. For this reason we maintain that further investigation is necessary and that new questions useful for the evaluation of the obsessive-compulsive behavior should be added to the ORTO-15 questionnaire.

  4. Characterisation of commercial Perna canaliculus samples and development of extemporaneous oral veterinary paste formulations containing Perna.

    PubMed

    Juliano, Claudia; Manconi, Paola; Cossu, Massimo

    2016-09-01

    Perna canaliculus is a nutritional supplement recently studied and highly recommended for its anti-inflammatory effects in both animals and humans. In this study, the physicochemical properties, the microbiological quality, the total lipid content and fatty acids composition of three commercial samples of Perna powder were determined. Subsequently, three simple formulations of extemporaneous oral pastes containing Perna were prepared and designed for veterinary use. Their microbiological stability was assessed after 1-month storage at either room temperature or 35 °C. The results demonstrated that commercial Perna samples lack homogeneity, in regard to some technological properties and fatty acid composition; therefore, a preliminary characterisation of commercial Perna samples is recommended to assure the quality of formulations containing this nutritional supplement. Oral paste formulations are easy and simple to prepare and show good physical and microbiological stability, suggesting their large-scale production.

  5. Vortex- and CO2 -gas-assisted liquid-liquid microextraction with salt addition for the high-performance liquid chromatographic determination of furanic compounds in concentrated juices and dried fruits.

    PubMed

    Abu-Bakar, Nur-Bahiyah; Makahleh, Ahmad; Saad, Bahruddin

    2016-03-01

    A novel microextraction method based on vortex- and CO2 -assisted liquid-liquid microextraction with salt addition for the isolation of furanic compounds (5-hydroxymethyl-2-furaldehyde, 5-methyl-2-furaldehyde, 2-furaldehyde, 3-furaldehyde, 2-furoic and 3-furoic acids) was developed. Purging the sample with CO2 was applied after vortexing to enhance the phase separation and mass transfer of the analytes. The optimum extraction conditions were: extraction solvent (volume), propyl acetate (125 μL); sample pH, 2.4; vortexing time, 45 s; salt concentration, 25% w/v and purging time, 5 min. The analytes were separated using an ODS Hypersil C18 column (250×4.6 mm i.d, 5 μm) under gradient flow. The proposed method showed good linearities (r(2) >0.999), low detection limits (0.08-1.9 μg/L) and good recoveries (80.7-122%). The validated method was successfully applied for the determination of the furanic compounds in concentrated juice (mango, date, orange, pomegranate, roselle, mangosteen and soursop) and dried fruit (prune, date and apricot paste) samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Carbon-Based Fe₃O₄ Nanocomposites Derived from Waste Pomelo Peels for Magnetic Solid-Phase Extraction of 11 Triazole Fungicides in Fruit Samples.

    PubMed

    Ren, Keyu; Zhang, Wenlin; Cao, Shurui; Wang, Guomin; Zhou, Zhiqin

    2018-05-06

    Carbon-based Fe₃O₄ nanocomposites (C/Fe₃O₄ NCs) were synthesized by a simple one-step hydrothermal method using waste pomelo peels as the carbon precursors. The characterization results showed that they had good structures and physicochemical properties. The prepared C/Fe₃O₄ NCs could be applied as excellent and recyclable adsorbents for magnetic solid phase extraction (MSPE) of 11 triazole fungicides in fruit samples. In the MSPE procedure, several parameters including the amount of adsorbents, extraction time, the type and volume of desorption solvent, and desorption time were optimized in detail. Under the optimized conditions, the good linearity ( R ² > 0.9916), the limits of detection (LOD), and quantification (LOQ) were obtained in the range of 1⁻100, 0.12⁻0.55, and 0.39⁻1.85 μg/kg for 11 pesticides, respectively. Lastly, the proposed MSPE method was successfully applied to analyze triazole fungicides in real apple, pear, orange, peach, and banana samples with recoveries in the range of 82.1% to 109.9% and relative standard deviations (RSDs) below 8.4%. Therefore, the C/Fe₃O₄ NCs based MSPE method has a great potential for isolating and pre-concentrating trace levels of triazole fungicides in fruits.

  7. Screening of Cognitive Impairment in Schizophrenia: Reliability, Sensitivity, and Specificity of the Repeatable Battery for the Assessment of Neuropsychological Status in a Spanish Sample.

    PubMed

    De la Torre, Gabriel G; Perez, Maria J; Ramallo, Miguel A; Randolph, Christopher; González-Villegas, Macarena Bernal

    2016-04-01

    In recent years, a number of studies focusing on the evaluation of neuropsychological deficits in individuals with schizophrenia have shown deficits that include several cognitive functions. Attention deficits as well as memory or executive function deficits are common in this kind of disorder together with sustained attention problems, working memory deficiencies, and problem-solving difficulties, among many others. Currently, the Repeatable Battery for the Assessment of Neuropsychological Status (RBANS) is gaining special importance in the evaluation of the cognitive deficits associated with schizophrenia. In this article, we describe an RBANS screening in a sample of 88 Spanish patients diagnosed with schizophrenia. We also aimed to check the battery's reliability, sensitivity, and specificity in the studied sample. We performed a comparative study with 88 healthy participants. The results showed a reliability index value of α = .795 and an item value of α = .762. For total test reliability, we obtained an index value of α = .761 and an item value of α = .762. Sensitivity score was 87.5% and specificity 86.4%. RBANS obtained good reliability, sensitivity, and specificity scores and represents a good screening tool in detecting cognitive deficits associated with schizophrenia. © The Author(s) 2015.

  8. Subcritical water extraction of alkaloids in Sophora flavescens Ait. and determination by capillary electrophoresis with field-amplified sample stacking.

    PubMed

    Wang, Haiyan; Lu, Yuchao; Chen, Jie; Li, Junchao; Liu, Shuhui

    2012-01-25

    The extraction and determination of cytisine, sophocarpine, matrine, sophoridine and oxymatrine in Sophora flavescens Ait. were performed using subcritical water extraction and capillary electrophoresis with field-amplified sample stacking. The effects of extraction temperature, pressure, time and cycle number on the extraction yields were investigated systematically for accelerated solvent extraction with ethanol (ASE) and accelerated solvent extraction with water (subcritical water extraction, SWE). The extraction yields obtained using SWE, ASE, water ultrasonic extraction and chloroform soaking extraction methods were compared. The electrophoresis separation buffer was monosodium phosphate (pH 3.0; 110 mM)-isopropanol (85:15, v/v). The effect of phosphoric acid added to the sample matrix on the reproducibility of the peak heights of the analytes was also examined. Cytisine, sophoridine and oxymatrine showed good linearity (R(2)>0.999) within 0.125-4.0 μg/mL, and sophocarpine and matrine exhibited good linearity (R(2)>0.998) within 0.0625-2.0 μg/mL, with the detection limits in the range of 0.004-0.0013 μg/mL. The five alkaloid contents in medicinal plants from different sources and Sophora instant granule were determined and compared. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Using a colorimeter to develop an intrinsic silicone shade guide for facial prostheses.

    PubMed

    Over, L M; Andres, C J; Moore, B K; Goodacre, C J; Muñoz, C A

    1998-12-01

    To determine if using CIE L*a*b* color measurements of white facial skin could be correlated to those of silicone shade samples that visually matched the skin. Secondly, to see if a correlation in color measurements could be achieved between the silicone shade samples and duplicated silicone samples made using a shade-guide color formula. A color booth was designed according to ASTM specifications, and painted using a Munsell Value 8 gray. A Minolta colorimeter was used to make facial skin measurements on 15 white adults. The skin color was duplicated using custom-shaded silicone samples. A 7-step wedge silicone shade guide was then fabricated, representing the commonly encountered thicknesses when fabricating facial prostheses. The silicone samples were then measured with the Minolta colorimeter. The readings were compared with the previous L*a*b* readings from the corresponding patient's skin measurements, and the relative color difference was then calculated. Silicone samples were fabricated and analyzed for three of the patients to determine if duplication of the visually matched silicone specimen was possible using the silicone color formula, and if the duplicates were visually and colorimetrically equivalent to each other. The color difference Delta E and chromaticity was calculated, and the data were analyzed using a coefficient-of-variation formula expressed by percent. A Pearson Product Moment Correlation Coefficient was performed to determine if a correlation existed between the skin and the silicone samples at the p < or = .05 level. The highest correlation was found in the b* dimension for silicone thicknesses of 1 to 4 mm. For silicone thicknesses of 6 to 10 mm, the highest correlation was found in the L* dimension. All three dimensions had positive correlations (R2 > 0), but only the 1-mm and 4-mm b* readings were very strong. Patient and silicone L*a*b* measurement results showed very little change in the a* axis, while the L* and b* measurements showed more change in their numbers, with changes in depth for all patient silicone samples. Delta E numbers indicated the lowest Delta E at the 1-mm depth and the highest Delta E at the 10-mm depth. All duplicated samples matched their original silicone samples to a degree that visual evaluation could not distinguish any color differences. Using volumetric measurements, a shade guide was developed for all 15 patients. There was good correlation between the patient's colorimeter measurements and the silicone samples, with the b* color dimension the most reproducible, followed by the L* and the a*. Silicone samples at 6, 8, and 10 mm matched the patient the best, and this study showed that silicone samples can be duplicated successfully if a good patient-silicone match is obtained. Rayon flocking fibers and liquid makeup are effective at matching facial prostheses and can be used to develop a simple shade guide for patient application.

  10. Ovulation leads women to perceive sexy cads as good dads.

    PubMed

    Durante, Kristina M; Griskevicius, Vladas; Simpson, Jeffry A; Cantú, Stephanie M; Li, Norman P

    2012-08-01

    Why do some women pursue relationships with men who are attractive, dominant, and charming but who do not want to be in relationships--the prototypical sexy cad? Previous research shows that women have an increased desire for such men when they are ovulating, but it is unclear why ovulating women would think it is wise to pursue men who may be unfaithful and could desert them. Using both college-age and community-based samples, in 3 studies we show that ovulating women perceive charismatic and physically attractive men, but not reliable and nice men, as more committed partners and more devoted future fathers. Ovulating women perceive that sexy cads would be good fathers to their own children but not to the children of other women. This ovulatory-induced perceptual shift is driven by women who experienced early onset of puberty. Taken together, the current research identifies a novel proximate reason why ovulating women pursue relationships with sexy cads, complementing existing research that identifies the ultimate, evolutionary reasons for this behavior.

  11. Highly selective dopamine electrochemical sensor based on electrochemically pretreated graphite and nafion composite modified screen printed carbon electrode.

    PubMed

    Ku, Shuhao; Palanisamy, Selvakumar; Chen, Shen-Ming

    2013-12-01

    Herein, we report a highly selective dopamine electrochemical sensor based on electrochemically pretreated graphite/nafion composite modified screen printed carbon (SPC) electrode. Electrochemically activated graphite/nafion composite was prepared by using a simple electrochemical method. Scanning electron microscope (SEM) used to characterize the surface morphology of the fabricated composite electrode. The SEM result clearly indicates that the graphitic basal planes were totally disturbed and leads to the formation of graphite nanosheets. The composite modified electrode showed an enhanced electrocatalytic activity toward the oxidation of DA when compared with either electrochemical pretreated graphite or nafion SPC electrodes. The fabricated composite electrode exhibits a good electrocatalytic oxidation toward DA in the linear response range from 0.5 to 70 μM with the detection limit of 0.023 μM. The proposed sensor also exhibits very good selectivity and stability, with the appreciable sensitivity. In addition, the proposed sensor showed satisfactory recovery results toward the commercial pharmaceutical DA samples. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. [Consistency study of PowerPlex 21 kit and Goldeneye 20A kit and forensic application].

    PubMed

    Ren, He; Liu, Ying; Zhang, Qing-Xia; Jiao, Zhang-Ping

    2014-06-01

    To ensure the consistency of genotype results for PowerPlex 21 kit and Goldeneye 20A kit. The STR loci were amplified in DNA samples from 205 unrelated individuals in Beijing Han population. And consistency of 19 overlap STR loci typing were observed. The genetic polymorphism of D1S1656 locus was obtained. All 19 overlap loci typing showed consistent. The proportion of peak height of heterozygous loci in two kits showed no statistical difference (P > 0.05). The observed heterozygosis of D1S1656 was 0.878. The discrimination power was 0.949. The excluding probability of paternity of triplet was 0.751. The excluding probability of paternity of diploid was 0.506. The polymorphism information content was 0.810. PowerPlex 21 kit and Goldeneye 20A kit present a good consistency. The primer design is reasonable. The polymorphism of D1S1656 is good. The two kits can be used for human genetic analysis, paternity test, and individual identification in forensic practice.

  13. [The influence of professional degree on the knowledge of HIV, HBV and HCV infections in dentistry practice].

    PubMed

    Vitale, F; Di Benedetto, M A; Casuccio, A; Firenze, A; Calandra, G; Ballarò, F; Romano, N

    2005-01-01

    The knowledge and preventive practices toward the risk of infection with HIV, HBV and HCV were evaluated in a sample of 254 dentists and odontostomatologies in Palermo, by answering to an anonymous questionnaire sent by mail. Overall, most of the participants showed a good knowledge of the transmission pattern of blood-borne viruses as well as good practice for personal hygiene (washing of hands, routine use of gloves, etc.). However 80.8% answered to recap needles after use and more than 40% have had at least one needle injury during the last year in their occupational setting. Moreover, nearly 24% of the interviewed declared to have not made vaccination against Hepatitis B virus infection. Statistical analysis showed a significant correlation between better knowledge, safer practice and different teaching training suggesting that odontostomatology degree might be more appropriate for a better training in preventive medicine for blood borne pathogens. Data also suggest the need of continuous worker education to reduce occupational blood exposures in dentistry.

  14. An Analysis of the Connectedness to Nature Scale Based on Item Response Theory

    PubMed Central

    Pasca, Laura; Aragonés, Juan I.; Coello, María T.

    2017-01-01

    The Connectedness to Nature Scale (CNS) is used as a measure of the subjective cognitive connection between individuals and nature. However, to date, it has not been analyzed at the item level to confirm its quality. In the present study, we conduct such an analysis based on Item Response Theory. We employed data from previous studies using the Spanish-language version of the CNS, analyzing a sample of 1008 participants. The results show that seven items presented appropriate indices of discrimination and difficulty, in addition to a good fit. The remaining six have inadequate discrimination indices and do not present a good fit. A second study with 321 participants shows that the seven-item scale has adequate levels of reliability and validity. Therefore, it would be appropriate to use a reduced version of the scale after eliminating the items that display inappropriate behavior, since they may interfere with research results on connectedness to nature. PMID:28824509

  15. Electrochemistry of raloxifene on glassy carbon electrode and its determination in pharmaceutical formulations and human plasma.

    PubMed

    Bagheri, Akbar; Hosseini, Hadi

    2012-12-01

    The electrochemical behavior of raloxifene (RLX) on the surface of a glassy carbon electrode (GCE) has been studied by cyclic voltammetry (CV). The CV studies were performed in various supporting electrolytes, wide range of potential scan rates, and pHs. The results showed an adsorption-controlled and quasi-reversible process for the electrochemical reaction of RLX, and a probable redox mechanism was suggested. Under the optimum conditions, differential pulse voltammetry (DPV) was applied for quantitative determination of the RLX in pharmaceutical formulations. The DPV measurements showed that the anodic peak current of the RLX was linear to its concentration in the range of 0.2-50.0μM with a detection limit of 0.0750μM, relative standard deviation (RSD %) below 3.0%, and a good sensitivity. The proposed method was successfully applied for determination of the RLX in pharmaceutical and human plasma samples with a good selectivity and suitable recovery. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. First spaceborne phase altimetry over sea ice using TechDemoSat-1 GNSS-R signals

    NASA Astrophysics Data System (ADS)

    Li, Weiqiang; Cardellach, Estel; Fabra, Fran; Rius, Antonio; Ribó, Serni; Martín-Neira, Manuel

    2017-08-01

    A track of sea ice reflected Global Navigation Satellite System (GNSS) signal collected by the TechDemoSat-1 mission is processed to perform phase altimetry over sea ice. High-precision carrier phase measurements are extracted from coherent GNSS reflections at a high angle of elevation (>57°). The altimetric results show good consistency with a mean sea surface (MSS) model, and the root-mean-square difference is 4.7 cm with an along-track sampling distance of ˜140 m and a spatial resolution of ˜400 m. The difference observed between the altimetric results and the MSS shows good correlation with the colocated sea ice thickness data from Soil Moisture and Ocean Salinity. This is consistent with the reflecting surface aligned with the bottom of the ice-water interface, due to the penetration of the GNSS signal into the sea ice. Therefore, these high-precision altimetric results have potential to be used for determination of sea ice thickness.

  17. An improved biosensor for acetaldehyde determination using a bienzymatic strategy at poly(neutral red) modified carbon film electrodes.

    PubMed

    Ghica, Mariana Emilia; Pauliukaite, Rasa; Marchand, Nicolas; Devic, Eric; Brett, Christopher M A

    2007-05-15

    Improved biosensors for acetaldehyde determination have been developed using a bienzymatic strategy, based on a mediator-modified carbon film electrode and co-immobilisation of NADH oxidase and aldehyde dehydrogenase. Modification of the carbon film electrode with poly(neutral red) mediator resulted in a sensitive, low-cost and reliable NADH detector. Immobilisation of the enzymes was performed using encapsulation in a sol-gel matrix or cross-linking with glutaraldehyde. The bienzymatic biosensors were characterized by studying the influence of pH, applied potential and co-factors. The sol-gel and glutaraldehyde biosensors showed a linear response up to 60 microM and 100 microM, respectively, with detection limits of 2.6 microM and 3.3 microM and sensitivities were 1.7 microA mM(-1) and 5.6 microA mM(-1). The optimised biosensors showed good stability and good selectivity and have been tested for application for the determination of acetaldehyde in natural samples such as wine.

  18. Episodic future thinking reduces delay discounting and cigarette demand: an investigation of the good-subject effect.

    PubMed

    Stein, Jeffrey S; Tegge, Allison N; Turner, Jamie K; Bickel, Warren K

    2018-04-01

    Episodic future thinking (EFT), an intervention involving mental simulation of future events, has been shown to reduce both delay discounting and cigarette self-administration. In the present study, we extended these findings by showing that EFT in a web-based sample of smokers reduces delay discounting and intensity of demand for cigarettes (ad libitum consumption) in a hypothetical purchase task. No effect was observed on elasticity of demand (sensitivity to price) or cigarette craving. We also explored whether demand characteristics (specifically, the "good-subject" effect) might be responsible for observed effects. EFT participants were significantly better able than control participants to discern the experimental hypothesis. However, EFT participants were not better than controls at identifying whether they had been assigned to the experimental group and, likewise, showed no differences in attitudes about the experiment and experimenter. Importantly, effects of EFT on delay discounting and demand remained significant even when controlling for measures of demand characteristics, indicating that EFT's effects are independent of participants' perceptions about the experiment.

  19. The assessment of empathy in adolescence: A contribution to the Italian validation of the "Basic Empathy Scale".

    PubMed

    Albiero, Paolo; Matricardi, Giada; Speltri, Daniela; Toso, Diana

    2009-04-01

    The present study examined the validity of the Basic Empathy Scale (BES) [Jolliffe, D., & Farrington, D. P. (2006a). Development and validation of the Basic Empathy Scale. Journal of Adolescence, 29, 589-611; Jolliffe, D., & Farrington, D. P. (2006b). Examining the relationship between low empathy and bullying. Aggressive Behavior, 32(6), 540-550.] and found further evidence for the scale's good psychometric properties. The BES was administered to a sample of 655 Italian adolescents to examine the generalizability and reliability of its factor structure. The results of the confirmatory factor analysis showed a reasonable data fit with the two hypothesized BES domains of Cognitive Empathy and Affective Empathy. Scale reliability was also satisfactory, showing good internal consistency. Lastly, BES scores were significantly associated with other empathy questionnaire scores (the Interpersonal Reactivity Index and Balanced Emotional Empathy Scale) and with a scale measuring prosocial behavior. Research and practice implications are discussed.

  20. An in-depth psychometric analysis of the Connor-Davidson Resilience Scale: calibration with Rasch-Andrich model.

    PubMed

    Arias González, Víctor B; Crespo Sierra, María Teresa; Arias Martínez, Benito; Martínez-Molina, Agustín; Ponce, Fernando P

    2015-09-23

    The Connor-Davidson Resilience Scale (CD-RISC) is inarguably one of the best-known instruments in the field of resilience assessment. However, the criteria for the psychometric quality of the instrument were based only on classical test theory. The aim of this paper has focused on the calibration of the CD-RISC with a nonclinical sample of 444 adults using the Rasch-Andrich Rating Scale Model, in order to clarify its structure and analyze its psychometric properties at the level of item. Two items showed misfit to the model and were eliminated. The remaining 22 items form basically a unidimensional scale. The CD-RISC has good psychometric properties. The fit of both the items and the persons to the Rasch model was good, and the response categories were functioning properly. Two of the items showed differential item functioning. The CD-RISC has an obvious ceiling effect, which suggests to include more difficult items in future versions of the scale.

  1. An overview of radioactive waste disposal procedures of a nuclear medicine department

    PubMed Central

    Ravichandran, R.; Binukumar, J. P.; Sreeram, Rajan; Arunkumar, L. S.

    2011-01-01

    Radioactive wastes from hospitals form one of the various types of urban wastes, which are managed in developed countries in a safe and organized way. In countries where growth of nuclear medicine services are envisaged, implementations of existing regulatory policies and guidelines in hospitals in terms of handling of radioactive materials used in the treatment of patients need a good model. To address this issue, a brief description of the methods is presented. A designed prototype waste storage trolley is found to be of great help in decaying the I-131 solid wastes from wards before releasing to waste treatment plant of the city. Two delay tanks with collection time of about 2 months and delay time of 2 months alternately result in 6 releases of urine toilet effluents to the sewage treatment plant (STP) of the hospital annually. Samples of effluents collected at releasing time documented radioactive releases of I-131 much below recommended levels of bi-monthly release. External counting of samples showed good statistical correlation with calculated values. An overview of safe procedures for radioactive waste disposal is presented. PMID:21731225

  2. An overview of radioactive waste disposal procedures of a nuclear medicine department.

    PubMed

    Ravichandran, R; Binukumar, J P; Sreeram, Rajan; Arunkumar, L S

    2011-04-01

    Radioactive wastes from hospitals form one of the various types of urban wastes, which are managed in developed countries in a safe and organized way. In countries where growth of nuclear medicine services are envisaged, implementations of existing regulatory policies and guidelines in hospitals in terms of handling of radioactive materials used in the treatment of patients need a good model. To address this issue, a brief description of the methods is presented. A designed prototype waste storage trolley is found to be of great help in decaying the I-131 solid wastes from wards before releasing to waste treatment plant of the city. Two delay tanks with collection time of about 2 months and delay time of 2 months alternately result in 6 releases of urine toilet effluents to the sewage treatment plant (STP) of the hospital annually. Samples of effluents collected at releasing time documented radioactive releases of I-131 much below recommended levels of bi-monthly release. External counting of samples showed good statistical correlation with calculated values. An overview of safe procedures for radioactive waste disposal is presented.

  3. The Effect of Ag and Ag+N Ion Implantation on Cell Attachment Properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Urkac, Emel Sokullu; Oztarhan, Ahmet; Gurhan, Ismet Deliloglu

    2009-03-10

    Implanted biomedical prosthetic devices are intended to perform safely, reliably and effectively in the human body thus the materials used for orthopedic devices should have good biocompatibility. Ultra High Molecular Weight Poly Ethylene (UHMWPE) has been commonly used for total hip joint replacement because of its very good properties. In this work, UHMWPE samples were Ag and Ag+N ion implanted by using the Metal-Vapor Vacuum Arc (MEVVA) ion implantation technique. Samples were implanted with a fluency of 1017 ion/cm2 and extraction voltage of 30 kV. Rutherford Backscattering Spectrometry (RBS) was used for surface studies. RBS showed the presence of Agmore » and N on the surface. Cell attachment properties investigated with model cell lines (L929 mouse fibroblasts) to demonstrate that the effect of Ag and Ag+N ion implantation can favorably influence the surface of UHMWPE for biomedical applications. Scanning electron microscopy (SEM) was used to demonstrate the cell attachment on the surface. Study has shown that Ag+N ion implantation represents more effective cell attachment properties on the UHMWPE surfaces.« less

  4. Optimization of Analytical Conditions for a Rapid Determination of Aniline in Environmental Water by Liquid Chromatography/Tandem Mass Spectrometry.

    PubMed

    Furukawa, Koji; Hashimoto, Makoto; Kaneco, Satoshi

    2017-01-01

    A rapid determination of aniline in environmental water was examined based on liquid chromatography/tandem mass spectrometry (LC/MS/MS). Environmental water samples were diluted 20-fold with Mill-Q water and measured by LC/MS/MS after adding a surrogate substance (aniline-d 5 ). In the results of the present study, the calibration curve of aniline showed good linearity in the range of 0.05 - 2.0 μg/L. Since the RSD (repeatability) by measuring repeatedly an aniline standard solution (0.05 μg/L, n = 7) was 3.2%, the repeatability of this work was very excellent. In addition, the recovery rate of aniline in environmental water was in the range of 99.0 - 102% with RSD 3.4 - 7.7%, and very good recovery test results were obtained. From these results, this analytical method was confirmed to be effective for aniline measurements of environmental water samples. Also, it is possible to conduct rapid analyses of aniline in environmental water without any solid-phase extraction process, compared to the solid-phase extraction-GC/MS method.

  5. [Selenium deficiency in an organic extensive water buffalo farm].

    PubMed

    Große, Reinhard; Binici, Cagri; Pieper, Robert; Müller, Kerstin E

    2018-06-01

    This case report presents investigations of muscle problems in three male water buffaloes (1-2 years) kept extensively (loose housing, pasture). The bulls were presented because of listlessness and increased lying periods. They displayed difficulties to stand up, a stilted gait, and tremor in the legs. The determination of the selenium concentration by the measurement of glutathione peroxidase activity in whole blood samples (EDTA) demonstrated selenium deficiency in all three buffaloes. This confirmed the tentative diagnosis of nutritive myodystrophy due to selenium deficiency. Following a single injection of 1500 mg all-rac-alpha-tocopherol acetate and 11 mg sodium selenite, the bulls recovered clinically. The whole blood samples taken subsequently from seven adult water buffaloes on the farm showed selenium deficiency in all animals. Consequently, slow-release multi-trace element boluses were administered once orally - as far as possible - to all adult animals of the herd. After 1 year, a good to very good selenium supply was observed in all these buffaloes, except for one cow, in which bolus application had failed. Schattauer GmbH.

  6. Electrical Nanocontact Between Bismuth Nanowire Edges and Electrodes

    NASA Astrophysics Data System (ADS)

    Murata, Masayuki; Nakamura, Daiki; Hasegawa, Yasuhiro; Komine, Takashi; Uematsu, Daisuke; Nakamura, Shinichiro; Taguchi, Takashi

    2010-09-01

    Three methods for attaching electrodes to a bismuth nanowire sample were investigated. In the first and second methods, thin layers of titanium and copper were deposited by ion plating under vacuum onto the edge surface of individual bismuth nanowire samples that were encapsulated in a quartz template. Good electrical contact between the electrodes and the nanowire was achieved using silver epoxy and conventional solder on the thin-film layers in the first and second methods, respectively. In the third method, a low-melting-point solder was utilized and was also successful in achieving good electrical contact in air atmosphere. The connection methods showed no difference in terms of resistivity temperature dependence or Seebeck coefficient. The third method has an advantage in that nanocontact is easily achieved; however, diffusion of the solder into the nanowire allows contamination near the melting point of the solder. In the first and second methods, the thin-film layer enabled electrical contact to be more safely achieved than the direct contact used in the third method, because the thin-film layer prevented diffusion of binder components.

  7. Quantification of caffeine, trigonelline and nicotinic acid in espresso coffee: the influence of espresso machines and coffee cultivars.

    PubMed

    Caprioli, Giovanni; Cortese, Manuela; Maggi, Filippo; Minnetti, Caterina; Odello, Luigi; Sagratini, Gianni; Vittori, Sauro

    2014-06-01

    Caffeine, trigonelline and nicotinic acid are important bioactive constituents of coffee. In this work, the combination of different water temperatures and pressures in the settings of the espresso coffee (EC) machine was evaluated, to assess how these factors influence how effectively caffeine, trigonelline and nicotinic acid are extracted from both Arabica and Robusta samples. The proposed analytical method, based on a high performance liquid chromatography (HPLC) system coupled to a variable wavelength detector (VWD), showed good linearity (R²> 0.9985) and good recoveries (71-92%); after validation for three monitored compounds, the method was used to analyze 20 commercial samples. The combination of a temperature of 92 °C and pressure at 7 or 9 bar seems to be the ideal setting for the most efficient extraction of these compounds and consequently for their intake; the compound extracted in the greatest quantity was caffeine, which was in the range of 116.87-199.68 mg in a 25 ml cup of coffee.

  8. [Quality of shortenings available on the home market].

    PubMed

    Zbikowska, Anna; Rutkowska, Jarosława; Krygier, Krzysztof

    2006-01-01

    The aim of this work was to examine the quality of shortenings available on Polish market, produced home or imported. The quality of twelve 100% vegetable fats and lard was estimated. Both chemical (fatty acids composition, especially trans isomers content, acid value, peroxide value, anisidine value, Totox, iodine value and oxidative stability--Rancimat test) and physical (melting point, solid fat content--at temperatures from 5 to 50 degrees C) properties were measured. The fats were subject to sensoric examination. The parameters defining the freshness of examined fats and their shelf life for all examined samples were good and proved the good quality. Induction time (150 degrees C) for examined fats varied from 1,79 to 4,29h. Examined fats differed significantly in saturated fatty acids content (from 14,0 do 60,2%) and trans isomers (from 0,1 to 56,6%). Fats produced from palm oil are also present and there are fats with smaller trans fat acids content. Examined shortenings contained very small content of essential fatty acids (from 0,5 to 10,4), and they showed very different melting points (from 19,6 to 42,1 degrees C) and solid phase contents. In general the examined fats were of good sensoric value. Summing up the received results, it should be underlined that large disparity in the content of trans isomers in analysed samples was observed and definitely TFA content should be lowered.

  9. Measurement of narcolepsy symptoms: The Narcolepsy Severity Scale.

    PubMed

    Dauvilliers, Yves; Beziat, Severine; Pesenti, Carole; Lopez, Regis; Barateau, Lucie; Carlander, Bertrand; Luca, Gianina; Tafti, Mehdi; Morin, Charles M; Billiard, Michel; Jaussent, Isabelle

    2017-04-04

    To validate the Narcolepsy Severity Scale (NSS), a brief clinical instrument to evaluate the severity and consequences of symptoms in patients with narcolepsy type 1 (NT1). A 15-item scale to assess the frequency and severity of excessive daytime sleepiness, cataplexy, hypnagogic hallucinations, sleep paralysis, and disrupted nighttime sleep was developed and validated by sleep experts with patients' feedback. Seventy untreated and 146 treated adult patients with NT1 were evaluated and completed the NSS in a single reference sleep center. The NSS psychometric properties, score changes with treatment, and convergent validity with other clinical parameters were assessed. The NSS showed good psychometric properties with significant item-total score correlations. The factor analysis indicated a 3-factor solution with good reliability, expressed by satisfactory Cronbach α values. The NSS total score temporal stability was good. Significant NSS score differences were observed between untreated and treated patients (dependent sample, 41 patients before and after sleep therapy; independent sample, 29 drug-free and 105 treated patients). Scores were lower in the treated populations (10-point difference between groups), without ceiling effect. Significant correlations were found among NSS total score and daytime sleepiness (Epworth Sleepiness Scale, Mean Sleep Latency Test), depressive symptoms, and health-related quality of life. The NSS can be considered a reliable and valid clinical tool for the quantification of narcolepsy symptoms to monitor and optimize narcolepsy management. © 2017 American Academy of Neurology.

  10. Uniform Sampling Table Method and its Applications II--Evaluating the Uniform Sampling by Experiment.

    PubMed

    Chen, Yibin; Chen, Jiaxi; Chen, Xuan; Wang, Min; Wang, Wei

    2015-01-01

    A new method of uniform sampling is evaluated in this paper. The items and indexes were adopted to evaluate the rationality of the uniform sampling. The evaluation items included convenience of operation, uniformity of sampling site distribution, and accuracy and precision of measured results. The evaluation indexes included operational complexity, occupation rate of sampling site in a row and column, relative accuracy of pill weight, and relative deviation of pill weight. They were obtained from three kinds of drugs with different shape and size by four kinds of sampling methods. Gray correlation analysis was adopted to make the comprehensive evaluation by comparing it with the standard method. The experimental results showed that the convenience of uniform sampling method was 1 (100%), odds ratio of occupation rate in a row and column was infinity, relative accuracy was 99.50-99.89%, reproducibility RSD was 0.45-0.89%, and weighted incidence degree exceeded the standard method. Hence, the uniform sampling method was easy to operate, and the selected samples were distributed uniformly. The experimental results demonstrated that the uniform sampling method has good accuracy and reproducibility, which can be put into use in drugs analysis.

  11. Electro-focusing liquid extractive surface analysis (EF-LESA) coupled to mass spectrometry.

    PubMed

    Brenton, A Gareth; Godfrey, A Ruth

    2014-04-01

    Analysis of the chemical composition of surfaces by liquid sampling devices interfaced to mass spectrometry is attractive as the sample stream can be continuously monitored at good sensitivity and selectivity. A sampling probe has been constructed that takes discrete liquid samples (typically <100 nL) of a surface. It incorporates an electrostatic lens system, comprising three electrodes, to which static and pulsed voltages are applied to form a conical "liquid tip", employed to dissolve analytes at a surface. A prototype system demonstrates spatial resolution of 0.093 mm(2). Time of contact between the liquid tip and the surface is controlled to standardize extraction. Calibration graphs of different analyte concentrations on a stainless surface have been measured, together with the probe's reproducibility, carryover, and recovery. A leucine enkephalin-coated surface demonstrated good linearity (R(2) = 0.9936), with a recovery of 90% and a limit of detection of 38 fmol per single spot sampled. The probe is compact and can be fitted into automated sample analysis equipment having potential for rapid analysis of surfaces at a good spatial resolution.

  12. Electro-Focusing Liquid Extractive Surface Analysis (EF-LESA) Coupled to Mass Spectrometry

    PubMed Central

    2014-01-01

    Analysis of the chemical composition of surfaces by liquid sampling devices interfaced to mass spectrometry is attractive as the sample stream can be continuously monitored at good sensitivity and selectivity. A sampling probe has been constructed that takes discrete liquid samples (typically <100 nL) of a surface. It incorporates an electrostatic lens system, comprising three electrodes, to which static and pulsed voltages are applied to form a conical “liquid tip”, employed to dissolve analytes at a surface. A prototype system demonstrates spatial resolution of 0.093 mm2. Time of contact between the liquid tip and the surface is controlled to standardize extraction. Calibration graphs of different analyte concentrations on a stainless surface have been measured, together with the probe’s reproducibility, carryover, and recovery. A leucine enkephalin-coated surface demonstrated good linearity (R2 = 0.9936), with a recovery of 90% and a limit of detection of 38 fmol per single spot sampled. The probe is compact and can be fitted into automated sample analysis equipment having potential for rapid analysis of surfaces at a good spatial resolution. PMID:24597530

  13. Comparison of Directionally Solidified Samples Solidified Terrestrially and Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Angart, S.; Lauer, M.; Tewari, S. N.; Grugel, R. N.; Poirier, D. R.

    2014-01-01

    This article reports research that has been carried out under the aegis of NASA as part of a collaboration between ESA and NASA for solidification experiments on the International Space Station (ISS). The focus has been on the effect of convection on the microstructural evolution and macrosegregation in hypoeutectic Al-Si alloys during directional solidification (DS). Terrestrial DS-experiments have been carried out at Cleveland State University (CSU) and under microgravity on the International Space Station (ISS). The thermal processing-history of the experiments is well defined for both the terrestrially processed samples and the ISS-processed samples. As of this writing, two dendritic metrics was measured: primary dendrite arm spacings and primary dendrite trunk diameters. We have observed that these dendrite-metrics of two samples grown in the microgravity environment show good agreements with models based on diffusion controlled growth and diffusion controlled ripening, respectively. The gravity-driven convection (i.e., thermosolutal convection) in terrestrially grown samples has the effect of decreasing the primary dendrite arm spacings and causes macrosegregation. Dendrite trunk diameters also show differences between the earth- and space-grown samples. In order to process DS-samples aboard the ISS, the dendritic seed crystals were partially remelted in a stationary thermal gradient before the DS was carried out. Microstructural changes and macrosegregation effects during this period are described and have modeled.

  14. Development of Online Courseware on Thai Food Good Health

    ERIC Educational Resources Information Center

    Sompong, Narong; Kheerajitt, Cherdpong

    2012-01-01

    The objectives of this research were to: 1) develop the online courseware on Thai Food Good Health to support the Thai Kitchen to the world project; and 2) evaluate the courseware by the learners toward the courseware integrated using in aboard. The research sample were sampling for chefs, Thai restaurant owners, and the students who were studying…

  15. Measurement equivalence of seven selected items of posttraumatic growth between black and white adult survivors of Hurricane Katrina.

    PubMed

    Rhodes, Alison M; Tran, Thanh V

    2013-02-01

    This study examined the equivalence or comparability of the measurement properties of seven selected items measuring posttraumatic growth among self-identified Black (n = 270) and White (n = 707) adult survivors of Hurricane Katrina, using data from the Baseline Survey of the Hurricane Katrina Community Advisory Group Study. Internal consistency reliability was equally good for both groups (Cronbach's alphas = .79), as were correlations between individual scale items and their respective overall scale. Confirmatory factor analysis of a congeneric measurement model of seven selected items of posttraumatic growth showed adequate measures of fit for both groups. The results showed only small variation in magnitude of factor loadings and measurement errors between the two samples. Tests of measurement invariance showed mixed results, but overall indicated that factor loading, error variance, and factor variance were similar between the two samples. These seven selected items can be useful for future large-scale surveys of posttraumatic growth.

  16. Chemical composition, antimicrobial and antioxidant activities of anethole-rich oil from leaves of selected varieties of fennel [Foeniculum vulgare Mill. ssp. vulgare var. azoricum (Mill.) Thell].

    PubMed

    Senatore, Felice; Oliviero, Filomena; Scandolera, Elia; Taglialatela-Scafati, Orazio; Roscigno, Graziana; Zaccardelli, Massimo; De Falco, Enrica

    2013-10-01

    The chemical composition and biological activity of the essential oils obtained from the leaves of two different cultivars of Florence fennel cropped under three different fertilization treatments (Control not fertilized; Mineral Fertilization; Compost from Municipal Solid Wastes) have been analyzed. All the oils were characterized by high anethole concentration and some showed also a good percentage of limonene. Thus, the leaves of Florence fennel, which are agricultural wastes, could be used for the recovery of anethole to be used for its flavoring and biomedical properties. The antimicrobial activity expressed by assays on the examined oils indicates an appreciable effect, generally higher on Gram-positive bacteria. The various samples of Florence fennel analyzed did not show any results with FRAP test. The DPPH test showed a weak capacity of the samples to catch the free radicals from the solution, attributable to their content in anethole. © 2013.

  17. Psychometric properties of the Adolescent Dissociative Experiences Scale in a sample of Italian adolescents.

    PubMed

    Schimmenti, Adriano

    2016-01-01

    The purpose of this study was to examine the psychometric properties of the Italian translation of the Adolescent Dissociative Experiences Scale (A-DES). A sample of 1,806 high-school students between the ages of 13 and 18 years, recruited in 6 Italian cities, completed the A-DES. The A-DES showed high internal consistency, excellent item-to-scale homogeneity, good split-half reliability, and a single-factor structure. The scores of the Italian adolescents were comparable to those found in previous research with the measure. No gender differences were found in mean A-DES scores, but boys and girls showed different patterns of responses on A-DES items. Age differences were also found, with 13- and 18-year-old students scoring higher on the measure than the other participants. A cluster analysis showed that participants could be consistently grouped into 2 clusters of low- and high-dissociative adolescents. This study supports the A-DES as a reliable and valid screening measure for dissociative symptoms in adolescents.

  18. [The practical measurement of health literacy in Hungary and in international comparison].

    PubMed

    Koltai, Júlia; Kun, Eszter

    2016-12-01

    The study presents results of an innovative measurement of practical health literacy in international context. To show the level of practical health literacy in the Hungarian society and in international comparison. We measured practical health literacy with Newest Vital Sign test on a Hungarian national representative sample, asked from 1008 persons, between May and June, 2015 from population 16 years or older, using methodological standards of Eurobarometer. The sample is representative to the above mentioned population by gender, age, region and settlement-size. Based on Newest Vital Sign test, members of the Hungarian society have good practical health literacy. The accomplishment is inconsistent with self-reported health literacy, since it shows weak results. As low level of self-reported health literacy implies that respondents don't have daily routine in practicing their skills, we could draw people's attention to food-information, that are important and show, how to utilize them. Orv. Hetil., 2016, 157(50), 2002-2006.

  19. Jacket-free stir bar sorptive extraction with bio-inspired polydopamine-functionalized immobilization of cross-linked polymer on stainless steel wire.

    PubMed

    Zhang, Zixin; Zhang, Wenpeng; Bao, Tao; Chen, Zilin

    2015-08-14

    Stainless steel wire (SSW) is a good substrate for stir bar sorptive extraction (SBSE). However, it is still a challenge to immobilize commonly used cross-linked polymers onto SSW. In this work, we present a new approach for immobilization of the cross-linked organic polymer onto SSW for jacket-free SBSE. A dopamine derivative was firstly synthesized; by introducing a mussel-inspired polydopamine process, a stable coating layer was finally generated on the surface of SSW. Secondly, the cross-linked polymer was synthesized on the polydopamine-modified SSW by using acetonitrile as the porogen, acrylamide (AA) as the functional monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linker and 2,2'-azobis (2-methylpropionitrile) as the initiator. A diluted pre-polymerization solution was carefully prepared to generate a thin layer of the polymer. The prepared poly(EGDMA-AA)-modified stir bar showed high stability and good tolerance toward stirring, ultrasonication, organic solvents, and strong acidic and basic conditions. Morphology and structure characterization of coatings were performed by scanning electron microscopy and Fourier transform infrared spectra, respectively. The prepared poly(EGDMA-AA)-modified stir bar showed great extraction efficiency toward protoberberines, with enrichment factors of 19-42. An SBSE-HPLC method was also developed for quantitative analysis of protoberberines. The method showed low limits of detection (0.06-0.15 ng mL(-1)), wide linear range (0.5-400 ng mL(-1)), good linearity (R≥0.9980) and good reproducibility (RSD≤3.60% for intra-day, RSD≤4.73% for inter-day). The developed method has been successfully applied to determine protoberberines in herb and rat plasma samples, with recoveries of 88.53-114.61%. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. An ATMND/SGI based label-free and fluorescence ratiometric aptasensor for rapid and highly sensitive detection of cocaine in biofluids.

    PubMed

    Wang, Jiamian; Song, Jie; Wang, Xiuyun; Wu, Shuo; Zhao, Yanqiu; Luo, Pinchen; Meng, Changgong

    2016-12-01

    A label-free ratiometric fluorescence aptasensor has been developed for the rapid and sensitive detection of cocaine in complex biofluids. The fluorescent aptasensor is composed of a non-labeled GC-38 cocaine aptamer which serves as a basic sensing unit and two fluorophores, 2-amino-5,6,7-trimethyl-1,8-naphthyridine (ATMND) and SYBR Green I (SGI) which serves as a signal reporter and a build-in reference, respectively. The detection principle is based on a specific cocaine mediated ATMND displacement reaction and the corresponding change in the fluorescence ratio of ATMND to SGI. Due to the high affinity of the non-labeled aptamer, the good precision originated from the ratiometric method, and the good fluorescence quantum yield of the fluorophore, the aptasensor shows good analytical performance with respect to cocaine detection. Under optimal conditions, the aptasensor shows a linear range of 0.10-10μM and a low limit of detection of 56nM, with a fast response of 20s. The low limit of detection is comparable to most of the fluorescent aptasensors with signal amplification strategies and much lower than all of the unamplified cocaine aptasensors. Practical sample analysis in a series of complex biofluids, including urine, saliva and serum, also indicates the good precision, stability, and high sensitivity of the aptasensor, which may have great potential for the point-of-care screening of cocaine in complex biofluids. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Structural parameterization and functional prediction of antigenic polypeptome sequences with biological activity through quantitative sequence-activity models (QSAM) by molecular electronegativity edge-distance vector (VMED).

    PubMed

    Li, ZhiLiang; Wu, ShiRong; Chen, ZeCong; Ye, Nancy; Yang, ShengXi; Liao, ChunYang; Zhang, MengJun; Yang, Li; Mei, Hu; Yang, Yan; Zhao, Na; Zhou, Yuan; Zhou, Ping; Xiong, Qing; Xu, Hong; Liu, ShuShen; Ling, ZiHua; Chen, Gang; Li, GenRong

    2007-10-01

    Only from the primary structures of peptides, a new set of descriptors called the molecular electronegativity edge-distance vector (VMED) was proposed and applied to describing and characterizing the molecular structures of oligopeptides and polypeptides, based on the electronegativity of each atom or electronic charge index (ECI) of atomic clusters and the bonding distance between atom-pairs. Here, the molecular structures of antigenic polypeptides were well expressed in order to propose the automated technique for the computerized identification of helper T lymphocyte (Th) epitopes. Furthermore, a modified MED vector was proposed from the primary structures of polypeptides, based on the ECI and the relative bonding distance of the fundamental skeleton groups. The side-chains of each amino acid were here treated as a pseudo-atom. The developed VMED was easy to calculate and able to work. Some quantitative model was established for 28 immunogenic or antigenic polypeptides (AGPP) with 14 (1-14) A(d) and 14 other restricted activities assigned as "1"(+) and "0"(-), respectively. The latter comprised 6 A(b)(15-20), 3 A(k)(21-23), 2 E(k)(24-26), 2 H-2(k)(27 and 28) restricted sequences. Good results were obtained with 90% correct classification (only 2 wrong ones for 20 training samples) and 100% correct prediction (none wrong for 8 testing samples); while contrastively 100% correct classification (none wrong for 20 training samples) and 88% correct classification (1 wrong for 8 testing samples). Both stochastic samplings and cross validations were performed to demonstrate good performance. The described method may also be suitable for estimation and prediction of classes I and II for major histocompatibility antigen (MHC) epitope of human. It will be useful in immune identification and recognition of proteins and genes and in the design and development of subunit vaccines. Several quantitative structure activity relationship (QSAR) models were developed for various oligopeptides and polypeptides including 58 dipeptides and 31 pentapeptides with angiotensin converting enzyme (ACE) inhibition by multiple linear regression (MLR) method. In order to explain the ability to characterize molecular structure of polypeptides, a molecular modeling investigation on QSAR was performed for functional prediction of polypeptide sequences with antigenic activity and heptapeptide sequences with tachykinin activity through quantitative sequence-activity models (QSAMs) by the molecular electronegativity edge-distance vector (VMED). The results showed that VMED exhibited both excellent structural selectivity and good activity prediction. Moreover, the results showed that VMED behaved quite well for both QSAR and QSAM of poly-and oligopeptides, which exhibited both good estimation ability and prediction power, equal to or better than those reported in the previous references. Finally, a preliminary conclusion was drawn: both classical and modified MED vectors were very useful structural descriptors. Some suggestions were proposed for further studies on QSAR/QSAM of proteins in various fields.

  2. Use of ATR-FTIR spectroscopy coupled with chemometrics for the authentication of avocado oil in ternary mixtures with sunflower and soybean oils.

    PubMed

    Jiménez-Sotelo, Paola; Hernández-Martínez, Maylet; Osorio-Revilla, Guillermo; Meza-Márquez, Ofelia Gabriela; García-Ochoa, Felipe; Gallardo-Velázquez, Tzayhrí

    2016-07-01

    Avocado oil is a high-value and nutraceutical oil whose authentication is very important since the addition of low-cost oils could lower its beneficial properties. Mid-FTIR spectroscopy combined with chemometrics was used to detect and quantify adulteration of avocado oil with sunflower and soybean oils in a ternary mixture. Thirty-seven laboratory-prepared adulterated samples and 20 pure avocado oil samples were evaluated. The adulterated oil amount ranged from 2% to 50% (w/w) in avocado oil. A soft independent modelling class analogy (SIMCA) model was developed to discriminate between pure and adulterated samples. The model showed recognition and rejection rate of 100% and proper classification in external validation. A partial least square (PLS) algorithm was used to estimate the percentage of adulteration. The PLS model showed values of R(2) > 0.9961, standard errors of calibration (SEC) in the range of 0.3963-0.7881, standard errors of prediction (SEP estimated) between 0.6483 and 0.9707, and good prediction performances in external validation. The results showed that mid-FTIR spectroscopy could be an accurate and reliable technique for qualitative and quantitative analysis of avocado oil in ternary mixtures.

  3. Honey Antibacterial Effect Boosting Using Origanum vulgare L. Essential Oil

    PubMed Central

    Imtara, Hamada; Elamine, Youssef

    2018-01-01

    The appearance of new bacterial strains which cause pathogenic diseases and which are resistant to the most used antibiotics requires probing new antibacterial agents sources. Therefore, the main aim of the present work was to follow the antibacterial activity of honey samples from Palestine and Morocco, after the combination with Origanum vulgare L. essential oil, and figure out whether the honey physicochemical parameters and geographic origin influence the final activity. The results of this study showed good geographical discrimination between the Palestinians and Moroccan honey samples. The antioxidant and antimicrobial activities showed a significant correlation with honey color, melanoidins, and phenolic and flavonoids contents. Furthermore, the possible effect of honey physicochemical parameters on the gained antimicrobial activities was assessed using the principal component analysis (PCA). Some parameters showed a promising effect and seem to be important in the process of honey samples selection. Namely, melanoidins content, phenolic content, electrical conductivity, and mineral content were shown to be positively influencing the gained antibacterial activity after the combination with essential oil against the tested strains, although a significant negative correlation was seen with the FIC only in the case of Escherichia coli (ATB: 57). PMID:29736180

  4. Honey Antibacterial Effect Boosting Using Origanum vulgare L. Essential Oil.

    PubMed

    Imtara, Hamada; Elamine, Youssef; Lyoussi, Badiâa

    2018-01-01

    The appearance of new bacterial strains which cause pathogenic diseases and which are resistant to the most used antibiotics requires probing new antibacterial agents sources. Therefore, the main aim of the present work was to follow the antibacterial activity of honey samples from Palestine and Morocco, after the combination with Origanum vulgare L. essential oil, and figure out whether the honey physicochemical parameters and geographic origin influence the final activity. The results of this study showed good geographical discrimination between the Palestinians and Moroccan honey samples. The antioxidant and antimicrobial activities showed a significant correlation with honey color, melanoidins, and phenolic and flavonoids contents. Furthermore, the possible effect of honey physicochemical parameters on the gained antimicrobial activities was assessed using the principal component analysis (PCA). Some parameters showed a promising effect and seem to be important in the process of honey samples selection. Namely, melanoidins content, phenolic content, electrical conductivity, and mineral content were shown to be positively influencing the gained antibacterial activity after the combination with essential oil against the tested strains, although a significant negative correlation was seen with the FIC only in the case of Escherichia coli (ATB: 57).

  5. Testing the applicability of a benthic foraminiferal-based transfer function for the reconstruction of paleowater depth changes in Rhodes (Greece) during the early Pleistocene.

    PubMed

    Milker, Yvonne; Weinkauf, Manuel F G; Titschack, Jürgen; Freiwald, Andre; Krüger, Stefan; Jorissen, Frans J; Schmiedl, Gerhard

    2017-01-01

    We present paleo-water depth reconstructions for the Pefka E section deposited on the island of Rhodes (Greece) during the early Pleistocene. For these reconstructions, a transfer function (TF) using modern benthic foraminifera surface samples from the Adriatic and Western Mediterranean Seas has been developed. The TF model gives an overall predictive accuracy of ~50 m over a water depth range of ~1200 m. Two separate TF models for shallower and deeper water depth ranges indicate a good predictive accuracy of 9 m for shallower water depths (0-200 m) but far less accuracy of 130 m for deeper water depths (200-1200 m) due to uneven sampling along the water depth gradient. To test the robustness of the TF, we randomly selected modern samples to develop random TFs, showing that the model is robust for water depths between 20 and 850 m while greater water depths are underestimated. We applied the TF to the Pefka E fossil data set. The goodness-of-fit statistics showed that most fossil samples have a poor to extremely poor fit to water depth. We interpret this as a consequence of a lack of modern analogues for the fossil samples and removed all samples with extremely poor fit. To test the robustness and significance of the reconstructions, we compared them to reconstructions from an alternative TF model based on the modern analogue technique and applied the randomization TF test. We found our estimates to be robust and significant at the 95% confidence level, but we also observed that our estimates are strongly overprinted by orbital, precession-driven changes in paleo-productivity and corrected our estimates by filtering out the precession-related component. We compared our corrected record to reconstructions based on a modified plankton/benthos (P/B) ratio, excluding infaunal species, and to stable oxygen isotope data from the same section, as well as to paleo-water depth estimates for the Lindos Bay Formation of other sediment sections of Rhodes. These comparisons indicate that our orbital-corrected reconstructions are reasonable and reflect major tectonic movements of Rhodes during the early Pleistocene.

  6. Testing the applicability of a benthic foraminiferal-based transfer function for the reconstruction of paleowater depth changes in Rhodes (Greece) during the early Pleistocene

    PubMed Central

    Weinkauf, Manuel F. G.; Titschack, Jürgen; Freiwald, Andre; Krüger, Stefan; Jorissen, Frans J.; Schmiedl, Gerhard

    2017-01-01

    We present paleo-water depth reconstructions for the Pefka E section deposited on the island of Rhodes (Greece) during the early Pleistocene. For these reconstructions, a transfer function (TF) using modern benthic foraminifera surface samples from the Adriatic and Western Mediterranean Seas has been developed. The TF model gives an overall predictive accuracy of ~50 m over a water depth range of ~1200 m. Two separate TF models for shallower and deeper water depth ranges indicate a good predictive accuracy of 9 m for shallower water depths (0–200 m) but far less accuracy of 130 m for deeper water depths (200–1200 m) due to uneven sampling along the water depth gradient. To test the robustness of the TF, we randomly selected modern samples to develop random TFs, showing that the model is robust for water depths between 20 and 850 m while greater water depths are underestimated. We applied the TF to the Pefka E fossil data set. The goodness-of-fit statistics showed that most fossil samples have a poor to extremely poor fit to water depth. We interpret this as a consequence of a lack of modern analogues for the fossil samples and removed all samples with extremely poor fit. To test the robustness and significance of the reconstructions, we compared them to reconstructions from an alternative TF model based on the modern analogue technique and applied the randomization TF test. We found our estimates to be robust and significant at the 95% confidence level, but we also observed that our estimates are strongly overprinted by orbital, precession-driven changes in paleo-productivity and corrected our estimates by filtering out the precession-related component. We compared our corrected record to reconstructions based on a modified plankton/benthos (P/B) ratio, excluding infaunal species, and to stable oxygen isotope data from the same section, as well as to paleo-water depth estimates for the Lindos Bay Formation of other sediment sections of Rhodes. These comparisons indicate that our orbital-corrected reconstructions are reasonable and reflect major tectonic movements of Rhodes during the early Pleistocene. PMID:29166653

  7. Performance of the cobas Hepatitis B virus (HBV) test using the cobas 4800 system and comparison of HBV DNA quantification ability between the COBAS AmpliPrep/COBAS TaqMan HBV test version 2.0 and cobas HBV test.

    PubMed

    Shin, Kyung-Hwa; Lee, Hyun-Ji; Chang, Chulhun L; Kim, Hyung-Hoi

    2018-04-01

    Hepatitis B virus (HBV) DNA levels are used to predict the response to therapy, determine therapy initiation, monitor resistance to therapy, and establish treatment success. To verify the performance of the cobas HBV test using the cobas 4800 system for HBV DNA quantification and to compare the HBV DNA quantification ability between the cobas HBV test and COBAS AmpliPrep/COBAS TaqMan HBV version 2.0 (CAP/CTM v2.0). The precision, linearity, and limit of detection of the cobas HBV test were evaluated using the 4th World Health Organization International Standard material and plasma samples. Clinical samples that yielded quantitative results using the CAP/CTM v2.0 and cobas HBV tests were subjected to correlational analysis. Three hundred forty-nine samples were subjected to correlational analysis, among which 114 samples showed results above the lower limit of quantification. Comparable results were obtained ([cobas HBV test] = 1.038 × [CAP/CTM v2.0]-0.173, r = 0.914) in 114 samples, which yielded values above the lower limit of quantification. The results for 86.8% of the samples obtained using the cobas HBV test were within 0.5 log 10 IU/mL of the CAP/CTM v2.0 results. The total precision values against the low and high positive controls were 1.4% (mean level: 2.25 log 10 IU/mL) and 3.2% (mean level: 6.23 log 10 IU/mL), respectively. The cobas HBV test demonstrated linearity (1.15-6.75 log 10 IU/mL, y = 0.95 × 6 + 0.17, r 2  = 0.994). The cobas HBV test showed good correlation with CAP/CTM v2.0, and had good precision and an acceptable limit of detection. The cobas HBV test using the cobas 4800 is a reliable method for quantifying HBV DNA levels in the clinical setting. Copyright © 2018. Published by Elsevier B.V.

  8. 7 CFR 28.406 - Strict Good Ordinary Color.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Strict Good Ordinary Color. 28.406 Section 28.406... for the Color Grade of American Upland Cotton § 28.406 Strict Good Ordinary Color. Strict Good Ordinary Color is color which is within the range represented by a set of samples in the custody of the...

  9. 7 CFR 28.406 - Strict Good Ordinary Color.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Strict Good Ordinary Color. 28.406 Section 28.406... for the Color Grade of American Upland Cotton § 28.406 Strict Good Ordinary Color. Strict Good Ordinary Color is color which is within the range represented by a set of samples in the custody of the...

  10. 7 CFR 28.406 - Strict Good Ordinary Color.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Strict Good Ordinary Color. 28.406 Section 28.406... for the Color Grade of American Upland Cotton § 28.406 Strict Good Ordinary Color. Strict Good Ordinary Color is color which is within the range represented by a set of samples in the custody of the...

  11. 7 CFR 28.406 - Strict Good Ordinary Color.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Strict Good Ordinary Color. 28.406 Section 28.406... for the Color Grade of American Upland Cotton § 28.406 Strict Good Ordinary Color. Strict Good Ordinary Color is color which is within the range represented by a set of samples in the custody of the...

  12. Story Goodness in Adolescents with Autism Spectrum Disorder (ASD) and in Optimal Outcomes from ASD

    ERIC Educational Resources Information Center

    Canfield, Allison R.; Eigsti, Inge-Marie; de Marchena, Ashley; Fein, Deborah

    2016-01-01

    Purpose: This study examined narrative quality of adolescents with autism spectrum disorder (ASD) using a well-studied "story goodness" coding system. Method: Narrative samples were analyzed for distinct aspects of story goodness and rated by naïve readers on dimensions of story goodness, accuracy, cohesiveness, and oddness. Adolescents…

  13. 7 CFR 28.406 - Strict Good Ordinary Color.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strict Good Ordinary Color. 28.406 Section 28.406... for the Color Grade of American Upland Cotton § 28.406 Strict Good Ordinary Color. Strict Good Ordinary Color is color which is within the range represented by a set of samples in the custody of the...

  14. Nutrient Enhancement of Fruit and Effects of Storage Conditions

    DTIC Science & Technology

    1998-05-01

    Cubed, peeled apples, approximately 0.25 in (0.6 cm) Ingredients - apples, high fructose corn syrup , ascorbic and citric acid, (to...addition, a field study of the products also showed high acceptability. Samples stored at 40, 70 and 100 °F were tested at zero time, 1,3, 6, 9, and 12...foods of good nutrition and high sensory acceptability with a reduced cost of processing. Such foods will deliver a high density of nutrients

  15. Psychometric properties of the questionnaire of cognitive and affective empathy in a Portuguese sample.

    PubMed

    Queirós, Andreia; Fernandes, Eugénia; Reniers, Renate; Sampaio, Adriana; Coutinho, Joana; Seara-Cardoso, Ana

    2018-01-01

    Empathy is an important concept in psychology and cognitive neuroscience. Despite the controversy around its definition, most researchers would agree that empathy is a multidimensional phenomenon which involves a vicarious experience of another person's affective state and an understanding of another person's affective experience. Self-report measures of empathy constitute an important tool for both research and clinical practice. The main goal of this study was to adapt and study the psychometric properties of the Questionnaire of Cognitive and Affective Empathy (QCAE), a worldwide used measure of empathy, in a Portuguese community sample (N = 562). Confirmatory factor analyses supported the factor structure of the original QCAE. Results show that the Portuguese version of the QCAE has sound psychometric properties, with good structural validity and internal consistency for both scales (i.e., affective and cognitive) and respective subscales of the instrument (i.e., Emotion Contagion, Proximal Responsivity, Peripheral Responsivity, Perspective Taking and Online Simulation). We tested both a five correlated factor structure (Model 1) and a second-order model that postulates the affective and cognitive dimensions (Model 2). Our results show that while both models present acceptable goodness of fit indices, Model 1 performs slightly better. In conclusion, the Portuguese version of the QCAE may prove a useful tool for future cross-cultural assessments of empathy in both research and clinical practice.

  16. A novel enzymatic glucose sensor based on Pt nanoparticles-decorated hollow carbon spheres-modified glassy carbon electrode

    NASA Astrophysics Data System (ADS)

    Luhana, Charles; Bo, Xiang-Jie; Ju, Jian; Guo, Li-Ping

    2012-10-01

    A new glucose biosensor was developed based on hollow carbon spheres decorated with platinum nanoparticles (Pt/HCSs)-modified glassy carbon electrode immobilized with glucose oxidase (GOx) with the help of Nafion. The Pt nanoparticles were well dispersed on the HCSs with an average size of 2.29 nm. The detection of glucose was achieved via electrochemical detection of the enzymatically liberated H2O2 at +0.5 V versus Ag/AgCl at physiologic pH of 7.4. The Pt/HCSs-modified electrode exhibited excellent electrocatalytic activities toward both the oxidation and reduction of H2O2. The glucose biosensor showed good electrocatalytic performance in terms of high sensitivity (4.1 μA mM-1), low detection limit (1.8 μM), fast response time <3 s, and wide linear range (0.04-8.62 mM). The apparent Michaelis-Menten constant ( K m) and the maximum current density ( i max) values for the biosensor were 10.94 mM and 887 μA cm-2 respectively. Furthermore, this biosensor showed an acceptable reproducibility and high stability. The interfering signals from ascorbic acid and uric acid at concentration levels normally found in human blood were not much compared with the response to glucose. Blood serum samples were also tested with this biosensor and a good recovery was achieved for the two spiked serum samples.

  17. Titanium dioxide solid phase for inorganic species adsorption and determination: the case of arsenic.

    PubMed

    Vera, R; Fontàs, C; Anticó, E

    2017-04-01

    We have evaluated a new titanium dioxide (Adsorbsia As600) for the adsorption of both inorganic As (V) and As (III) species. In order to characterize the sorbent, batch experiments were undertaken to determine the capacities of As (III) and As (V) at pH 7.3, which were found to be 0.21 and 0.14 mmol g -1 , respectively. Elution of adsorbed species was only possible using basic solutions, and arsenic desorbed under batch conditions was 50 % when 60 mg of loaded titanium dioxide was treated with 0.5 M NaOH solution. Moreover, its use as a sorbent for solid-phase extraction and preconcentration of arsenic species from well waters has been investigated, without any previous pretreatment of the sample. Solid-phase extraction was implemented by packing several minicolumns with Adsorbsia As600. The method has been validated showing good accuracy and precision. Acceptable recoveries were obtained when spiked waters at 100-200 μg L -1 were measured. The presence of major anions commonly found in waters did not affect arsenic adsoption, and only silicate at 100 mg L -1 level severely competed with arsenic species to bind to the material. Finally, the measured concentrations in water samples containing arsenic from the Pyrinees (Catalonia, Spain) showed good agreement with the ICP-MS results.

  18. Evaluation of the automated hematology analyzer ADVIA® 120 for cerebrospinal fluid analysis and usage of unique hemolysis reagent.

    PubMed

    Tanada, H; Ikemoto, T; Masutani, R; Tanaka, H; Takubo, T

    2014-02-01

    In this study, we evaluated the performance of the ADVIA 120 hematology system for cerebrospinal fluid (CSF) assay. Cell counts and leukocyte differentials in CSF were examined with the ADVIA 120 hematology system, while simultaneously confirming an effective hemolysis agent for automated CSF cell counts. The detection limits of both white blood cell (WBC) counts and red blood cell (RBC) counts on the measurement of CSF cell counts by the ADVIA 120 hematology system were superior at 2 cells/μL (10(-6) L). The WBC count was linear up to 9.850 cells/μL, and the RBC count was linear up to approximately 20 000 cells/μL. The intrarun reproducibility indicated good precision. The leukocyte differential of CSF cells, performed by the ADVIA120 hematology system, showed good correlation with the microscopic procedure. The VersaLyse hemolysis solution efficiently lysed the samples without interfering with cell counts and leukocyte differential, even in a sample that included approximately 50 000/μL RBC. These data show the ADVIA 120 hematology system correctly measured the WBC count and leukocyte differential in CSF. The VersaLyse hemolysis solution is considered to be optimal for hemolysis treatment of CSF when measuring cell counts and differentials by the ADVIA 120 hematology system. © 2013 John Wiley & Sons Ltd.

  19. Factor solutions of the Social Phobia Scale (SPS) and the Social Interaction Anxiety Scale (SIAS) in a Swedish population.

    PubMed

    Mörtberg, Ewa; Reuterskiöld, Lena; Tillfors, Maria; Furmark, Tomas; Öst, Lars-Göran

    2017-06-01

    Culturally validated rating scales for social anxiety disorder (SAD) are of significant importance when screening for the disorder, as well as for evaluating treatment efficacy. This study examined construct validity and additional psychometric properties of two commonly used scales, the Social Phobia Scale and the Social Interaction Anxiety Scale, in a clinical SAD population (n = 180) and in a normal population (n = 614) in Sweden. Confirmatory factor analyses of previously reported factor solutions were tested but did not reveal acceptable fit. Exploratory factor analyses (EFA) of the joint structure of the scales in the total population yielded a two-factor model (performance anxiety and social interaction anxiety), whereas EFA in the clinical sample revealed a three-factor solution, a social interaction anxiety factor and two performance anxiety factors. The SPS and SIAS showed good to excellent internal consistency, and discriminated well between patients with SAD and a normal population sample. Both scales showed good convergent validity with an established measure of SAD, whereas the discriminant validity of symptoms of social anxiety and depression could not be confirmed. The optimal cut-off score for SPS and SIAS were 18 and 22 points, respectively. It is concluded that the factor structure and the additional psychometric properties of SPS and SIAS support the use of the scales for assessment in a Swedish population.

  20. Eggshell membrane-based biotemplating of mixed hemimicelle/admicelle as a solid-phase extraction adsorbent for carcinogenic polycyclic aromatic hydrocarbons.

    PubMed

    Wang, Weidong; Chen, Bo; Huang, Yuming

    2014-08-13

    A new solid-phase extraction (SPE) format was demonstrated, based on eggshell membrane (ESM) templating of the mixed hemimicelle/admicelle of linear alkylbenzenesulfonates (LAS) as an adsorbent for the enrichment of carcinogenic polycyclic aromatic hydrocarbons (PAHs) in environmental aqueous samples. The LAS mixed hemimicelle/admicelle formation and SPE of the target PAHs were conducted simultaneously by adding the organic target and LAS through a column filled with 500 mg of ESM. The effect of various factors, including LAS concentration, solution pH, ionic strength, and humic acid concentration on the recoveries of PAHs were investigated and optimized. The results showed that LAS concentration and solution pH had obvious effect on extraction of PAHs, and the recoveries of PAHs compounds decreased in the presence of salt and humic acid. Under the optimized analytical conditions, the present method could respond down to 0.1-8.6 ng/L PAHs with a linear calibration ranging from 0.02 to 10 μg/L, showing a good PAHs enrichment ability with high sensitivity. The developed method was used satisfactorily for the detection of PAHs in environmental water samples. The mixed hemimicelle/admicelle adsorbent exhibited high extraction efficiency to PAHs and good selectivity with respect to natural organic matter and was advantageous over commercial C₁₈ adsorbent, for example, high extraction yield, high breakthrough volume, and easy regeneration.

Top