9 CFR 113.111 - Clostridium Perfringens Type C Toxoid and Bacterin-Toxoid.
Code of Federal Regulations, 2013 CFR
2013-01-01
... a prescribed test shall not be released. (a) Purity test. Final container samples of completed... § 113.26. (b) Safety test. Bulk or final container samples of completed product from each serial shall be tested for safety as provided in § 113.33(b). (c) Potency test. Bulk or final container samples of...
9 CFR 113.111 - Clostridium Perfringens Type C Toxoid and Bacterin-Toxoid.
Code of Federal Regulations, 2014 CFR
2014-01-01
... a prescribed test shall not be released. (a) Purity test. Final container samples of completed... § 113.26. (b) Safety test. Bulk or final container samples of completed product from each serial shall be tested for safety as provided in § 113.33(b). (c) Potency test. Bulk or final container samples of...
9 CFR 113.111 - Clostridium Perfringens Type C Toxoid and Bacterin-Toxoid.
Code of Federal Regulations, 2012 CFR
2012-01-01
... a prescribed test shall not be released. (a) Purity test. Final container samples of completed... § 113.26. (b) Safety test. Bulk or final container samples of completed product from each serial shall be tested for safety as provided in § 113.33(b). (c) Potency test. Bulk or final container samples of...
Mitchell, J M; McNab, W B; Yee, A J; Griffiths, M W; McEwen, S A; Spilsbury, L; Boison, J O
1998-08-01
The Lactek test, marketed for antimicrobial residue detection in milk, was validated for the detection of antimicrobial residues in tissues. A previous study found that the LacTek test could confidently identify tissue samples spiked with antimicrobial residues. However, the test could not reliably distinguish violative from nonviolative spiked samples relative to Canadian maximum residue limits (MRLs). The objectives of this study were to assess and compare the performance of the LacTek tests for beta-lactams, tetracyclines, gentamicin, and sulfamethazine on samples containing naturally incurred residues by running the test in parallel with the standard microbial inhibition test (MIT) presently used for the routine testing of tissues at our facility and to assess the agreement with high pressure liquid chromatographic (HPLC) determinative methods. Parallel testing with the official MIT found that the Lactek tests could be confidently used for testing tissue samples containing incurred residues. Among 1,008 MIT-positive samples, the LacTek test found that 90% contained beta-lactams and/or tetracyclines. A further 7.3% of violative residues could not be identified to an antimicrobial class. In addition, 9% of samples testing negative on the MIT were found to contain an antimicrobial residue by the LacTek tests. Comparative testing with HPLC methods found that there was very good agreement between the two tests and that most violations were due to penicillin G and oxytetracycline. Although the LacTek test cannot be used to distinguish violative from nonviolative residue levels, it does offer several advantages over the present MIT. These include speed, ease of use, the ability to identify residues to a specific class, and an improved sensitivity at the MRL level for the most commonly found antimicrobials in tissue.
9 CFR 113.110 - Clostridium Botulinum Type C Bacterin-Toxoid.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., safety, and potency as prescribed in this section. A serial found unsatisfactory by any prescribed test shall not be released. (a) Purity test. Final container samples of completed product from each serial... test. Bulk or final container samples of completed product from each serial shall be tested for safety...
9 CFR 113.110 - Clostridium Botulinum Type C Bacterin-Toxoid.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., safety, and potency as prescribed in this section. A serial found unsatisfactory by any prescribed test shall not be released. (a) Purity test. Final container samples of completed product from each serial... test. Bulk or final container samples of completed product from each serial shall be tested for safety...
Turner, Terry D.; Beller, Laurence S.; Clark, Michael L.; Klingler, Kerry M.
1997-01-01
A method of processing a test sample to concentrate an analyte in the sample from a solvent in the sample includes: a) boiling the test sample containing the analyte and solvent in a boiling chamber to a temperature greater than or equal to the solvent boiling temperature and less than the analyte boiling temperature to form a rising sample vapor mixture; b) passing the sample vapor mixture from the boiling chamber to an elongated primary separation tube, the separation tube having internal sidewalls and a longitudinal axis, the longitudinal axis being angled between vertical and horizontal and thus having an upper region and a lower region; c) collecting the physically transported liquid analyte on the internal sidewalls of the separation tube; and d) flowing the collected analyte along the angled internal sidewalls of the separation tube to and pass the separation tube lower region. The invention also includes passing a turbulence inducing wave through a vapor mixture to separate physically transported liquid second material from vaporized first material. Apparatus are also disclosed for effecting separations. Further disclosed is a fluidically powered liquid test sample withdrawal apparatus for withdrawing a liquid test sample from a test sample container and for cleaning the test sample container.
Turner, T.D.; Beller, L.S.; Clark, M.L.; Klingler, K.M.
1997-10-14
A method of processing a test sample to concentrate an analyte in the sample from a solvent in the sample includes: (a) boiling the test sample containing the analyte and solvent in a boiling chamber to a temperature greater than or equal to the solvent boiling temperature and less than the analyte boiling temperature to form a rising sample vapor mixture; (b) passing the sample vapor mixture from the boiling chamber to an elongated primary separation tube, the separation tube having internal sidewalls and a longitudinal axis, the longitudinal axis being angled between vertical and horizontal and thus having an upper region and a lower region; (c) collecting the physically transported liquid analyte on the internal sidewalls of the separation tube; and (d) flowing the collected analyte along the angled internal sidewalls of the separation tube to and pass the separation tube lower region. The invention also includes passing a turbulence inducing wave through a vapor mixture to separate physically transported liquid second material from vaporized first material. Apparatus is also disclosed for effecting separations. Further disclosed is a fluidically powered liquid test sample withdrawal apparatus for withdrawing a liquid test sample from a test sample container and for cleaning the test sample container. 8 figs.
Ashour, M S; Abdelaziz, A A; Hefni, H; el-Tayeb, O M
1989-06-01
We examined a total of 54 samples, including 18 body lotions and 36 talcum powders, for their total aerobic bacterial, coliform and fungal counts. We also carried out anaerobic bacterial counts for talcum powder as well as tests to detect some potentially hazardous bacteria in all tested samples. Talcum powders were more heavily contaminated with bacteria and fungi than body lotions. More than 40% of the tested body lotions contained no viable bacteria or less than 100 c.f.u./g. while all the talcum powders tested contained more than 100 c.f.u./g. Thirty per cent of the talcum powders were contaminated with 10(4) c.f.u./g. and none of the body lotions were contaminated to that extent. No coliforms were recovered from any of the body lotions, while 17% of the talcum powder examined contained coliforms in the range of 230-500 c.f.u./g. Staphylococcus spp. were detected in 18 samples of both talcum powders and body lotions, three of these Staphylococci were of the aureus type. Three samples of talcum powder contained E. coli, two samples contained Enterobacter agglomerans and one sample contained Citrobacter freundii. Seventy per cent of the body lotions showed no fungal counts, while 83% of the talcum powders examined were contaminated with fungi and most of the contaminated talcum powders contained more than 100 fungal cells/g. With regard to the anaerobic bacterial counts for talcum powders, 50% of the samples showed no counts while the other 50% contained less than 100 c.f.u./g. Four samples were contaminated with Clostridium perfringens, although C. tetani was not recovered from any of the samples.
Code of Federal Regulations, 2013 CFR
2013-01-01
... refrigerated samples should contain ice or ice packs to maintain temperatures of 0° to 5 °C, unless a different temperature is required for the sample to be tested. (d) Containers for frozen samples should contain dry ice...
Code of Federal Regulations, 2012 CFR
2012-01-01
... refrigerated samples should contain ice or ice packs to maintain temperatures of 0° to 5 °C, unless a different temperature is required for the sample to be tested. (d) Containers for frozen samples should contain dry ice...
Code of Federal Regulations, 2014 CFR
2014-01-01
... refrigerated samples should contain ice or ice packs to maintain temperatures of 0° to 5 °C, unless a different temperature is required for the sample to be tested. (d) Containers for frozen samples should contain dry ice...
Code of Federal Regulations, 2011 CFR
2011-01-01
... refrigerated samples should contain ice or ice packs to maintain temperatures of 0° to 5 °C, unless a different temperature is required for the sample to be tested. (d) Containers for frozen samples should contain dry ice...
Code of Federal Regulations, 2010 CFR
2010-01-01
... refrigerated samples should contain ice or ice packs to maintain temperatures of 0° to 5 °C, unless a different temperature is required for the sample to be tested. (d) Containers for frozen samples should contain dry ice...
10 CFR 26.168 - Blind performance testing.
Code of Federal Regulations, 2014 CFR
2014-01-01
... analyte and must be certified by immunoassay and confirmatory testing; (2) Drug positive. These samples must contain a measurable amount of the target drug or analyte in concentrations ranging between 150... performance test sample must contain a measurable amount of the target drug or analyte in concentrations...
10 CFR 26.168 - Blind performance testing.
Code of Federal Regulations, 2010 CFR
2010-01-01
... analyte and must be certified by immunoassay and confirmatory testing; (2) Drug positive. These samples must contain a measurable amount of the target drug or analyte in concentrations ranging between 150... performance test sample must contain a measurable amount of the target drug or analyte in concentrations...
10 CFR 26.168 - Blind performance testing.
Code of Federal Regulations, 2011 CFR
2011-01-01
... analyte and must be certified by immunoassay and confirmatory testing; (2) Drug positive. These samples must contain a measurable amount of the target drug or analyte in concentrations ranging between 150... performance test sample must contain a measurable amount of the target drug or analyte in concentrations...
10 CFR 26.168 - Blind performance testing.
Code of Federal Regulations, 2013 CFR
2013-01-01
... analyte and must be certified by immunoassay and confirmatory testing; (2) Drug positive. These samples must contain a measurable amount of the target drug or analyte in concentrations ranging between 150... performance test sample must contain a measurable amount of the target drug or analyte in concentrations...
10 CFR 26.168 - Blind performance testing.
Code of Federal Regulations, 2012 CFR
2012-01-01
... analyte and must be certified by immunoassay and confirmatory testing; (2) Drug positive. These samples must contain a measurable amount of the target drug or analyte in concentrations ranging between 150... performance test sample must contain a measurable amount of the target drug or analyte in concentrations...
Sample introduction apparatus for a flow cytometer
Van den Engh, Ger
1998-01-01
A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning HPLC tubing and fittings may be used in a manner which facilitates removable of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it.
Sample introduction system for a flow cytometer
Van den Engh, Ger
1997-01-01
A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning, HPLC tubing and fittings may be used in a manner which facilitates removing of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it.
Sample introduction apparatus for a flow cytometer
Van den Engh, G.
1998-03-10
A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning HPLC tubing and fittings may be used in a manner which facilitates removable of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it. 3 figs.
Sample introduction system for a flow cytometer
Engh, G. van den
1997-02-11
A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning, HPLC tubing and fittings may be used in a manner which facilitates removing of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it. 3 figs.
Quality Control of Direct Molecular Diagnostics for Methicillin-Resistant Staphylococcus aureus▿
van Belkum, Alex; Niesters, Hubert G. M.; MacKay, William G.; van Leeuwen, Willem B.
2007-01-01
Ten samples containing various amounts of methicillin-resistant Staphylococcus aureus (MRSA), methicillin-susceptible S. aureus, methicillin-resistant Staphylococcus epidermidis (MRSE), and combinations thereof were distributed to 51 laboratories for molecular diagnostics testing. Samples containing 102 to 103 MRSA cells were frequently reported to be negative. MRSE samples were scored as negative by all commercial tests but by only two out of three in-house tests. PMID:17581936
Larson, E L; Strom, M S; Evans, C A
1980-01-01
Tests were performed using the sterile bag technique to determine the effects of type of sampling solution, use of antiseptic neutralizers, and solution temperature on the detection and quantitation of bacteria on hands. Using paired hand cultures, three sampling solutions were compared: quarter-strength Ringer solution, a phosphate buffer containing Triton X-100, and the same buffer containing antiseptic neutralizers. The phosphate buffer containing Triton X-100 was significantly better than quarter-strength Ringer solution in mean bacterial yield; the neutralizer-containing sampling solution was slightly better than Triton X-100-containing solution, although differences were not significant at the P = 0.05 level. Temperature (6 or 23 degrees C) of the sampling solution showed no consistent effect on bacterial yield from hands tested with the fluid containing neutralizers. PMID:7012171
Decaro, Nicola; Desario, Costantina; Elia, Gabriella; Campolo, Marco; Lorusso, Alessio; Mari, Viviana; Martella, Vito; Buonavoglia, Canio
2007-01-26
A total of 29 faecal samples collected from dogs with diarrhoea following canine parvovirus (CPV) vaccination were tested by minor groove binder (MGB) probe assays for discrimination between CPV vaccine and field strains and by diagnostic tests for detection of other canine pathogens. Fifteen samples tested positive only for CPV field strains; however, both vaccine and field strains were detected in three samples. Eleven samples were found to contain only the vaccine strain, although eight of them tested positive for other pathogens of dogs. Only three samples were found to contain the vaccine strain without evidence of canine pathogens. The present study confirms that most cases of parvovirus-like disease occurring shortly after vaccination are related to infection with field strains of canine parvovirus type 2 (CPV-2) rather than to reversion to virulence of the modified live virus contained in the vaccine.
Phase II test plan for the evaluation of the performance of container filling systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
BOGER, R.M.
The PHMC will provide tank wastes for final treatment by BNFL from Hanford's waste tanks. Concerns about the ability for ''grab'' sampling to provide large volumes of representative waste samples has led to the development of a nested, fixed-depth sampling system. Preferred concepts for filling sample containers that meet RCRA organic sample criteria were identified by a PHMC Decision Board. These systems will replace the needle based sampling ''T'' that is currently on the sampling system. This test plan document identifies cold tests with simulants that will demonstrate the preferred bottle filling concepts abilities to provide representative waste samples andmore » will meet RCRA criteria. Additional tests are identified that evaluate the potential for cross-contamination between samples and the ability for the system to decontaminate surfaces which have contacted tank wastes. These tests will be performed with kaolid/water and sand/water slurry simulants in the test rig that was used by AEAT to complete Phase 1 tests in FY 1999.« less
Chemical analysis kit for the presence of explosives
Eckels, Joel Del [Livermore, CA; Nunes,; Peter, J [Danville, CA; Alcaraz, Armando [Livermore, CA; Whipple, Richard E [Livermore, CA
2011-05-10
A tester for testing for explosives associated with a test location comprising a first explosives detecting reagent; a first reagent holder, the first reagent holder containing the first explosives detecting reagent; a second explosives detecting reagent; a second reagent holder, the second reagent holder containing the second explosives detecting reagent; a sample collection unit for exposure to the test location, exposure to the first explosives detecting reagent, and exposure to the second explosives detecting reagent; and a body unit containing a heater for heating the sample collection unit for testing the test location for the explosives.
Use of ferric chloride to identify salicylate-containing poisons.
Hoffman, Robert J; Nelson, Lewis S; Hoffman, Robert S
2002-01-01
Ferric chloride (FeCl3) is used to qualitatively test the urine of patients with presumed salicylate exposure. FeCl3 testing of an unidentified poison might provide evidence of salicylate exposure in situations where FeCl3 urine testing cannot be used. Such situations include the absence of a urine sample, immediately after ingestion before urine contains a detectable quantity of salicylate, or for patients chronically using salicylatesfor which FeCl3 testing is unhelpful. This study seeks to determine if FeCl3 can be used to identify salicylate-containing products. We assessed the reactivity of FeCl3 with commercially available salicylate-containing products. We applied 0.1 mL of 10% FeCl3 solution to each of 15 various salicylate-containing products including: regular and buffered acetylsalicylic acid, bismuth subsalicylate, methylsalicylate, physostigmine salicylate, salicylic acid, trolamine salicylate, and herbal tablets with salicin-containing white willow bark (Salix sp.). These products tested were: regular and enteric-coatedpills (n = 4), powder (n = 1), topical creams (n = 5), topical liquids (n = 4), and intravenous solution (n = 1). FeCl3 was applied to crushed tablets and added directly to liquids and creams. Fifteen salicylate-free controls including liquids, pills, and creams similar in appearance to experimental samples were also tested. Three blinded physiciansfamiliar with FeCl3 testing independently observed the addition of FeCl3 to each sample and rated a positive or negative result. All salicylate-containing products were interpreted to be clearly FeCl3 positive and all control samples were interpreted to be clearly FeCl3 negative. Salicylate-containing products may be identified using FeCl33. When using FeCl3
Wheelock, Craig E.; Miller, Jeff L.; Miller, Mike J.; Phillips, Bryn M.; Gee, Shirley J.; Tjeerdema, Ronald S.; Hammock, Bruce D.
2006-01-01
Pyrethroid insecticides are known for their potential toxicity to aquatic invertebrates and many fish species. A significant problem in the study of pyrethroid toxicity is their extreme hydrophobicity. They can adsorb to test container surfaces and many studies, therefore, report pyrethroid levels as nominal water concentrations. In this study, pyrethroid adsorption to sampling and test containers was measured and several container treatments were examined for their ability to decrease pyrethroid adsorption. None of the chemical treatments were successful at preventing pyrethroid loss from aqueous samples, but vortexing of containers served to resuspend pyrethroids. The effects of the observed adsorption on Ceriodaphnia dubia and Hyalella azteca permethrin toxicity were examined. Species-specific results showed a time-dependent decrease in toxicity following pyrethroid adsorption to test containers for C. dubia, but not for H. azteca. These results demonstrate that pyrethroid adsorption to containers can significantly affect the observed outcome in toxicity-testing and serves as a caution for researchers and testing laboratories. PMID:15951033
Grantina-Ievina, Lelde; Andersone, Una; Berkolde-Pīre, Dace; Nikolajeva, Vizma; Ievinsh, Gederts
2013-12-01
The aim of the present paper was to show that differences in biological activity among commercially produced vermicompost samples can be found by using a relatively simple test system consisting of microorganism tests on six microbiological media and soilless seedling growth tests with four vegetable crop species. Significant differences in biological properties among analyzed samples were evident both at the level of microbial load as well as plant growth-affecting activity. These differences were mostly manufacturer- and feedstock-associated, but also resulted from storage conditions of vermicompost samples. A mature vermicompost sample that was produced from sewage sludge still contained considerable number of Escherichia coli. Samples from all producers contained several potentially pathogenic fungal species such as Aspergillus fumigatus, Pseudallescheria boidii, Pseudallescheria fimeti, Pseudallescheria minutispora, Scedosporium apiospermum, Scedosporium prolificans, Scopulariopsis brevicaulis, Stachybotrys chartarum, Geotrichum spp., Aphanoascus terreus, and Doratomyces columnaris. In addition, samples from all producers contained plant growth-promoting fungi from the genera Trichoderma and Mortierella. The described system can be useful both for functional studies aiming at understanding of factors affecting quality characteristics of vermicompost preparations and for routine testing of microbiological quality and biological activity of organic waste-derived composts and vermicomposts.
Hossain, Mirza Akram; Friciu, Mihaela; Aubin, Sebastien; Leclair, Grégoire
2014-04-15
The stability of penicillin G sodium solutions stored in polyvinyl chloride (PVC) bags or elastomeric pump containers was studied. Test samples were prepared by diluting powdered penicillin G sodium (10 million units/10-mL vial) to solutions of 2,500 or 50,000 units/mL with 0.9% sodium chloride injection or 5% dextrose injection. The preparations were transferred to 250-mL PVC bags and elastomeric pump containers. All samples were prepared in triplicate and stored at 5°C. Chemical stability was measured by a stability-indicating high-performance liquid chromatographic (HPLC) assay and by pH evaluation. Particulate matter was evaluated according to compendial standards using a light-obscuration particle count test. Preparations were visually examined throughout the study. After 21 days of storage, all test samples remained chemically stable, with an HPLC assay recovery value of more than 90% of the initial value. After 28 days, all samples prepared with either diluent and stored in PVC bags, as well as the samples diluted to 2,500 units/mL with sodium chloride injection and stored in elastomeric pump containers, did not meet the recovery acceptance limit. For all test samples, the mean pH consistently decreased during storage, from about 6.4 to about 5.5. Particle counts remained acceptable throughout the study, and no change in appearance was observed. Penicillin G for injection (2,500 and 50,000 units/mL) diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 5°C in PVC containers or elastomeric pump containers was physically and chemically stable for a period of at least 21 days.
Shah, Manthan P; Shendell, Derek G; Meng, Qingyu; Ohman-Strickland, Pamela; Halperin, William
2018-04-23
The performances of a portable X-Ray Fluorescence (XRF) lead paint analyzer (RMD LPA-1, Protec Instrument Corp., Waltham, MA) and a commercially available colorimetric lead test kit (First Alert Lead Test Kit, eAccess Solutions, Inc., Palatine, IL) were evaluated for use by local or state health departments as potential cost-effective rapid analysis or "spot test" field techniques for tentative identification of lead content in sindoor powders. For both field-sampling methods, sensitivity, specificity and predictive values varied widely for samples containing <300,000 μg/g lead. For samples containing ≥300,000 μg/g lead, the aforementioned metrics were 100% (however, the CIs had a wide range). In addition, both field sampling methods showed clear, consistent positive readings only for samples containing ≥300,000 μg/g lead. Even samples with lead content as high as 5,110 μg/g were not positively identified by either field analysis technique. The results of this study suggest the XRF analyzer and colorimetric lead test kit cannot be used as a rapid field test for sindoor by health department inspectors.
White blood cell counting system
NASA Technical Reports Server (NTRS)
1972-01-01
The design, fabrication, and tests of a prototype white blood cell counting system for use in the Skylab IMSS are presented. The counting system consists of a sample collection subsystem, sample dilution and fluid containment subsystem, and a cell counter. Preliminary test results show the sample collection and the dilution subsystems are functional and fulfill design goals. Results for the fluid containment subsystem show the handling bags cause counting errors due to: (1) adsorption of cells to the walls of the container, and (2) inadequate cleaning of the plastic bag material before fabrication. It was recommended that another bag material be selected.
A Draft Protocol for Detecting Possible Biohazards in Martian Samples Returned to Earth
NASA Technical Reports Server (NTRS)
Viso, M.; DeVincenzi, D. L.; Race, M. S.; Schad, P. J.; Stabekis, P. D.; Acevedo, S. E.; Rummel, J. D.
2002-01-01
In preparation for missions to Mars that will involve the return of samples, it is necessary to prepare for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth. Previous groups and committees have studied selected aspects of sample return activities, but a specific protocol for handling and testing of returned -=1 samples from Mars remained to be developed. To refine the requirements for Mars sample hazard testing and to develop criteria for the subsequent release of sample materials from precautionary containment, NASA Planetary Protection Officer, working in collaboration with CNES, convened a series of workshops to produce a Protocol by which returned martian sample materials could be assessed for biological hazards and examined for evidence of life (extant or extinct), while safeguarding the samples from possible terrestrial contamination. The Draft Protocol was then reviewed by an Oversight and Review Committee formed specifically for that purpose and composed of senior scientists. In order to preserve the scientific value of returned martian samples under safe conditions, while avoiding false indications of life within the samples, the Sample Receiving Facility (SRF) is required to allow handling and processing of the Mars samples to prevent their terrestrial contamination while maintaining strict biological containment. It is anticipated that samples will be able to be shipped among appropriate containment facilities wherever necessary, under procedures developed in cooperation with international appropriate institutions. The SRF will need to provide different types of laboratory environments for carrying out, beyond sample description and curation, the various aspects of the protocol: Physical/Chemical analysis, Life Detection testing, and Biohazard testing. The main principle of these tests will be described and the criteria for release will be discussed, as well as the requirements for the SRF and its personnel.
Detection of cocaine in cargo containers by high-volume vapor sampling: field test at Port of Miami
NASA Astrophysics Data System (ADS)
Neudorfl, Pavel; Hupe, Michael; Pilon, Pierre; Lawrence, Andre H.; Drolet, Gerry; Su, Chih-Wu; Rigdon, Stephen W.; Kunz, Terry D.; Ulwick, Syd; Hoglund, David E.; Wingo, Jeff J.; Demirgian, Jack C.; Shier, Patrick
1997-02-01
The use of marine containers is a well known smuggling method for large shipments of drugs. Such containers present an ideal method of smuggling as the examination method is time consuming, difficult and expensive for the importing community. At present, various methods are being studied for screening containers which would allow to rapidly distinguish between innocent and suspicious cargo. Air sampling is one such method. Air is withdrawn for the inside of containers and analyzed for telltale vapors uniquely associated with the drug. The attractive feature of the technique is that the containers could be sampled without destuffing and opening, since air could be conveniently withdrawn via ventilation ducts. In the present paper, the development of air sampling methodology for the detection of cocaine hydrochloride will be discussed, and the results from a recent field test will be presented. The results indicated that vapors of cocaine and its decomposition product, ecgonidine methyl ester, could serve as sensitive indicators of the presence of the drug in the containers.
Hladik, Michelle; Orlando, James L.; Kuivila, Kathryn
2009-01-01
Loss of pyrethroid insecticides onto surfaces during sample collection can confound the interpretation of analytical and toxicity test results. Sample collection devices, container materials, and water matrix composition have a significant influence on the association of pyrethroids to container walls, which can be as high as 50 percent. Any sample collection method involving transfer through multiple containers or pieces of equipment increases the potential for pyrethroid loss. This loose 'surface-association' with container walls can be reversed through agitation. When sampling water matrices with pumps or autosamplers, no pyrethroids were lost as long as the water was moving continuously through the system. When collecting water matrices in containers, the material with the least amount of pyrethroid sorption is as follows: glass less than (<) plastic less than (<) Teflon. Additionally, pyrethroids were easier to re-suspend from the glass container walls. Since the amount of surface-association is proportional to the ratio of volume-to-contact-area of the sample, taking larger-volume field samples (greater than 3 liters) reduced pyrethroid losses to less than 10 percent. The amount of surface-association cannot be predicted easily because of the dependence on water matrix composition; samples with higher dissolved organic carbon or suspended-sediment concentrations were observed to have lower percent loss. Sediment samples were not affected by glass-container sorption (the only containers tested). Standardized sample-collection protocols are critical to yield accurate pyrethroid concentrations for assessment of potential effects, and have been summarized in an accompanying standard operating procedure.
Lu, Xujin; Lloyd, David K; Klohr, Steven E
2016-01-01
A feasibility study was conducted for a sensitive and robust dye immersion method for the measurement of container closure integrity of unopened prefilled syringes using fluorescence spectrophotometry as the detection method. A Varian Cary Eclipse spectrofluorometer was used with a custom-made sample holder to position the intact syringe in the sample compartment for fluorescence measurements. Methylene blue solution was initially evaluated as the fluorophore in a syringe with excitation at 607 nm and emission at 682 nm, which generated a limit of detection of 0.05 μg/mL. Further studies were conducted using rhodamine 123, a dye with stronger fluorescence. Using 480 nm excitation and 525 nm emission, the dye in the syringe could be easily detected at levels as low as 0.001 μg/mL. The relative standard deviation for 10 measurements of a sample of 0.005 μg/mL (with repositioning of the syringe after each measurement) was less than 1.1%. A number of operational parameters were optimized, including the photomultiplier tube voltage, excitation, and emission slit widths. The specificity of the testing was challenged by using marketed drug products and a protein sample, which showed no interference to the rhodamine detection. Results obtained from this study demonstrated that using rhodamine 123 for container closure integrity testing with in-situ (in-syringe) fluorescence measurements significantly enhanced the sensitivity and robustness of the testing and effectively overcame limitations of the traditional methylene blue method with visual or UV-visible absorption detection. Ensuring container closure integrity of injectable pharmaceutical products is necessary to maintain quality throughout the shelf life of a sterile drug product. Container closure integrity testing has routinely been used to evaluate closure integrity during product development and production line qualification of prefilled syringes, vials, and devices. However, container closure integrity testing has recently gained industry attention due to increased regulatory agency scrutiny regarding the analytical rigor of container closure integrity testing methods and expectations to use container closure integrity testing in lieu of sterility tests in stability programs. Methylene blue dye is often used for dye ingress testing of container closure integrity, but we found it unsuitable for reliable detection of small breaches in prefilled syringes of drug product. This work describes the suitability and advantages of using a fluorescent dye and spectroscopic detection for a robust, sensitive, and quality control-friendly container closure integrity testing method for prefilled syringes. © PDA, Inc. 2016.
40 CFR Appendix 1 to Subpart A of... - Static Sheen Test
Code of Federal Regulations, 2011 CFR
2011-07-01
... spatula used to mix the sample will be the principal sources of contamination problems. These problems... stirring bar. 4.1.7Stainless steel spatula. 4.1.8Test container: Open plastic container whose internal....1Plastic liners for the test container: Oil-free, heavy-duty plastic trash can liners that do not inhibit...
7 CFR 29.426 - Collection of pesticide test samples.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 2 2013-01-01 2013-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide residues...
7 CFR 29.426 - Collection of pesticide test samples.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 2 2011-01-01 2011-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide residues...
7 CFR 29.426 - Collection of pesticide test samples.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 2 2012-01-01 2012-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide residues...
7 CFR 29.426 - Collection of pesticide test samples.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 2 2014-01-01 2014-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide residues...
7 CFR 29.426 - Collection of pesticide test samples.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide residues...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamamoto, Takashi, E-mail: tyama@nies.go.jp; Kida, Akiko; Noma, Yukio
Highlights: • A high sensitive and selective testing method for asbestos in treated materials of asbestos containing wastes was developed. • Asbestos can be determined at a limits are a few million fibers per gram and a few μg g{sup −1}. • High temperature melting treatment samples were determined by this method. Asbestos fiber concentration were below the quantitation limit in all samples, and total fiber concentrations were determined as 47–170 × 10{sup 6} g{sup −1}. - Abstract: Appropriate treatment of asbestos-containing wastes is a significant problem. In Japan, the inertization of asbestos-containing wastes based on new treatment processes approvedmore » by the Minister of the Environment is promoted. A highly sensitive method for testing asbestos fibers in inertized materials is required so that these processes can be approved. We developed a method in which fibers from milled treated materials are extracted in water by shaking, and are counted and identified by transmission electron microscopy. Evaluation of this method by using asbestos standards and simulated slag samples confirmed that the quantitation limits are a few million fibers per gram and a few μg/g in a sample of 50 mg per filter. We used this method to assay asbestos fibers in slag samples produced by high-temperature melting of asbestos-containing wastes. Fiber concentrations were below the quantitation limit in all samples, and total fiber concentrations were determined as 47–170 × 10{sup −6} f/g. Because the evaluation of treated materials by TEM is difficult owing to the limited amount of sample observable, this testing method should be used in conjunction with bulk analytical methods for sure evaluation of treated materials.« less
ERIC Educational Resources Information Center
Richardson, Mary; Reischman, Diann
2011-01-01
This article describes an interactive activity that involves students participating in a memory recall test. Data collected from the activity may be used to illustrate the one-sample t test or one-sample sign test. (Contains 1 table and 1 figure.)
Strength of mortar containing rubber tire particle
NASA Astrophysics Data System (ADS)
Jusoh, M. A.; Abdullah, S. R.; Adnan, S. H.
2018-04-01
The main focus in this investigation is to determine the strength consist compressive and tensile strength of mortar containing rubber tire particle. In fact, from the previous study, the strength of mortar containing waste rubber tire in mortar has a slightly decreases compare to normal mortar. In this study, rubber tire particle was replacing on volume of fine aggregate with 6%. 9% and 12%. The sample were indicated M0 (0%), M6 (6%), M9 (9%) and M12 (12%). In this study, two different size of sample used with cube 100mm x 100mm x 100mm for compressive strength and 40mm x 40mm x 160mm for flexural strength. Morphology test was conducted by using Scanning electron microscopic (SEM) were done after testing compressive strength test. The concrete sample were cured for day 3, 7 and 28 before testing. Results compressive strength and flexural strength of rubber mortar shown improved compare to normal mortar.
Baldwin, C A; Beaulieu, H J; Buchan, R M; Johnson, H H
1982-01-01
Forty-one public schools in Colorado were drawn at random and surveyed for asbestos-containing materials. After bulk samples of possible asbestos materials from the schools were collected and analyzed, the K2 asbestos screening test was used to eliminate samples that did not contain asbestos. Samples with positive results on the K2 test were analyzed by an outside laboratory by polarized light microscopy. The risk of potential exposure presented by these materials was then assessed for each site from which a sample was taken. Of 113 samples collected, results were negative for asbestos for only 10.6 percent by the K2 test. Of the 101 samples for which results were positive, 56 actually contained 1 or more forms of asbestos. Twelve of these 56 samples were from sprayed material; the remaining 44 were from other materials containing asbestos. Of the 41 schools sampled, 31 had asbestos materials in one of more locations. The potential exposure values for these materials ranged from very low to very high, but the majority had high-exposure potentials. Estimates based on the survey of the 41 schools indicated that 63 to 89 percent of the public schools in Colorado have asbestos materials that present potentially serious hazards, not only to the children, teachers, and staff, but also to members of the community who use the school buildings after regular school hours.
[Improved method of studying the blood for sterility].
Talapa, A I
1983-05-01
The technique used for the inoculation and subculturing of blood samples in testing them for sterility is described. This technique eliminates the possibility of contaminating the culture medium and the blood sample under test with extraneous bacterial flora. Blood samples were inoculated without opening the containers with the culture medium. Inoculation was made with the syringe and the needle used for taking the blood sample through the punctured rubber stopper closing the container. Subculturing on solid culture media was also carried out without opening the containers: the rubber stopper was punctured and the contents of the container withdrawn with a pipette needle. The use of this new technique made it possible to detect bacteremia in 12.8% of cases, only in persons with purulent and septic diseases, whereas by using the existing technique bacteremia was detected both in sick and healthy persons, in 38.6% and 26.6% of cases, respectively.
2000-04-07
The Food and Drug Administration (FDA) is reclassifying over-the-counter (OTC) test sample collection systems for drugs of abuse testing from class III (premarket approval) into class I (general controls) and exempting them from premarket notification (510(k)) and current good manufacturing practice (CGMP) requirements. FDA is also designating OTC test sample collection systems for drugs of abuse testing as restricted devices under the Federal Food, Drug, and Cosmetic Act (the act) and establishing restrictions intended to assure consumers that: The underlying laboratory test(s) are accurate and reliable; the laboratory performing the test(s) has adequate expertise and competency; and the product has adequate labeling and methods of communicating test results to consumers. Finally, FDA is adding a conforming amendment to the existing classification regulation for specimen transport and storage containers to clarify that it does not apply to specimen transport and storage containers that are part of an OTC test sample collection system for the purpose of testing for the presence of drugs of abuse or their metabolites in a laboratory.
HNU-HANBY PCP IMMUNOASSAY TEST KIT - INNOVATIVE TECHNOLOGY EVALUATION REPORT
The HNU-Hanby pentachlorophenol (PCP) test kit rapidly analyzes for PCP in soil samples. The test kit can only detect those PCP carriers that contain aromatic compounds. The test kit estimates PCP concentrations in soil samples indirectly by measuring petroleum hydrocarbon carrie...
Differential auger spectrometry
Strongin, Myron; Varma, Matesh Narayan; Anne, Joshi
1976-06-22
Differential Auger spectroscopy method for increasing the sensitivity of micro-Auger spectroanalysis of the surfaces of dilute alloys, by alternately periodically switching an electron beam back and forth between an impurity free reference sample and a test sample containing a trace impurity. The Auger electrons from the samples produce representative Auger spectrum signals which cancel to produce an Auger test sample signal corresponding to the amount of the impurity in the test samples.
In vitro corrosion behaviour and microhardness of high-copper amalgams with platinum and indium.
Ilikli, B G; Aydin, A; Işimer, A; Alpaslan, G
1999-02-01
Samples prepared from Luxalloy, GS-80, Permite-C and Logic and polished after 24 h by traditional methods were stored in polypropylene tubes containing phosphate-buffered saline solutions (pH 3.5 and 6.5) and distilled water. The amounts of mercury, silver, tin, copper, zinc, platinum and indium in the test solutions were determined at the first, second, eighth, 52nd and 78th week by atomic absorption spectrometry. At the end of the eighth week the amalgam samples were removed from solutions and evaluated by Rockwell Super Scial Microhardness tester. Statistically significant low amounts of metal ions were measured for Permite-C containing indium and Logic containing platinum. The microhardness test results showed that there were statistically significant increases in the microhardness of Permite-C and Logic. As a result it was shown that the amalgam samples were affected from corrosion conditions to different degrees. Sample of the Logic group that was stored in distilled water, showed smoother surface properties than other amalgam samples containing high copper. However, it was observed that samples of Permite-C group had the smoothest surface properties.
Influence of Temperature on Free Radical Generation in Propolis-Containing Ointments
Ramos, Pawel; Pilawa, Barbara
2016-01-01
Free radicals thermally generated in the ointments containing propolis were studied by electron paramagnetic resonance (EPR) spectroscopy. The influence of temperature on the free radical concentration in the propolis ointments was examined. Two ointment samples with different contents of propolis (5 and 7%, resp.) heated at temperatures of 30°C, 40°C, 50°C, and 60°C, for 30 min., were tested. Homogeneously broadened EPR lines and fast spin-lattice interactions characterized all the tested samples. Free radicals concentrations in the propolis samples ranged from 1018 to 1020 spin/g and were found to grow in both propolis-containing ointments along with the increasing heating temperature. Free radical concentrations in the ointments containing 5% and 7% of propolis, respectively, heated at temperatures of 30°C, 40°C, and 50°C were only slightly different. Thermal treatment at the temperature of 60°C resulted in a considerably higher free radical formation in the sample containing 7% of propolis when related to the sample with 5% of that compound. The EPR examination indicated that the propolis ointments should not be stored at temperatures of 40°C, 50°C, and 60°C. Low free radical formation at the lowest tested temperatures pointed out that both examined propolis ointments may be safely stored up to the temperature of 30°C. PMID:27563336
A quarantine protocol for analysis of returned extraterrestrial samples
NASA Technical Reports Server (NTRS)
Bagby, J. R.; Sweet, H. C.; Devincenzi, D. L.
1983-01-01
A protocol is presented for the analysis at an earth-orbiting quarantine facility of return samples of extraterrestrial material that might contain (nonterrestrial) life forms. The protocol consists of a series of tests designed to determine whether the sample, conceptualized as a 1-kg sample of Martian soil, is free from nonterrestrial biologically active agents and so may safely be sent to a terrestrial containment facility, or it exhibits biological activity requiring further (second-order) testing outside the biosphere. The first-order testing procedure seeks to detect the presence of any replicating organisms or toxic substances through a series of experiments including gas sampling, analysis of radioactivity, stereomicroscopic inspection, chemical analysis, microscopic examination, the search for metabolic products under growth conditions, microbiologicl assays, and the challenge of cultured cells with any agents found or with the extraterrestrial material as is. Detailed plans for the second-order testing would be developed in response to the actual data received from primary testing.
GICHD Mine Dog Testing Project - Soil Sample Results No.3
DOE Office of Scientific and Technical Information (OSTI.GOV)
PHELAN, JAMES M.; BARNETT, JAMES L.; BENDER, SUSAN FAE ANN
2003-03-01
A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan and Bosnia containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performancemore » and seasonal weather conditions. This report documents the analytical chemical methods and results from the third batch of soils received. This batch contained samples from Kharga, Afghanistan collected in October 2002.« less
GICHD mine dog testing project : soil sample results #5.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnett, James L.; Phelan, James M.; Archuleta, Luisa M.
2004-01-01
A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performance and seasonalmore » weather conditions. This report documents the analytical chemical methods and results from the fifth batch of soils received. This batch contained samples from Kharga, Afghanistan collected in June 2003.« less
Mowitz, Martin; Zimerson, Erik; Svedman, Cecilia; Bruze, Magnus
2013-12-01
Oak moss absolute (Evernia prunastri extract) contains a large number of substances, among them the potent allergens atranol and chloroatranol. Since 2008, their content in oak moss absolute has been restricted by the International Fragrance Association to a maximum level of 100 ppm each. To compare the elicitation capacities of a traditional (sample A) and a treated (sample B) oak moss absolute containing, in total, 27 000 and 66 ppm of atranol and chloroatranol, respectively, and to investigate reactions to components of oak moss absolute separated by thin-layer chromatography (TLC). Fifteen oak moss-allergic subjects were patch tested with serial dilutions and TLC strips of samples A and B. Fifteen subjects reacted to sample A at concentrations ≤ 2.0%, and 2 subjects reacted to sample B at 2.0% but not to lower concentrations. Among 13 subjects reacting to the TLC strip of sample A, 11 reacted to spots with retardation factor values corresponding to those of atranol and/or chloroatranol, and 11 reacted to other areas on the TLC strip. Only one subject reacted to the TLC strip of sample B. The patch test reactivity of sample B was significantly lower than that of sample A. The TLC patch tests indicate the presence of sensitizers other than atranol and chloroatranol in oak moss absolute. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Code of Federal Regulations, 2010 CFR
2010-10-01
... that the ERMM meets the performance criteria contained in this appendix and that test verification data are available to a railroad or to FRA upon request. 2. The test verification data shall contain, at a minimum, all pertinent original data logs and documentation that the test sample preparation, test set up...
Code of Federal Regulations, 2011 CFR
2011-10-01
... that the ERMM meets the performance criteria contained in this appendix and that test verification data are available to a railroad or to FRA upon request. 2. The test verification data shall contain, at a minimum, all pertinent original data logs and documentation that the test sample preparation, test set up...
Code of Federal Regulations, 2014 CFR
2014-10-01
... that the ERMM meets the performance criteria contained in this appendix and that test verification data are available to a railroad or to FRA upon request. 2. The test verification data shall contain, at a minimum, all pertinent original data logs and documentation that the test sample preparation, test set up...
Code of Federal Regulations, 2012 CFR
2012-10-01
... that the ERMM meets the performance criteria contained in this appendix and that test verification data are available to a railroad or to FRA upon request. 2. The test verification data shall contain, at a minimum, all pertinent original data logs and documentation that the test sample preparation, test set up...
Code of Federal Regulations, 2013 CFR
2013-10-01
... that the ERMM meets the performance criteria contained in this appendix and that test verification data are available to a railroad or to FRA upon request. 2. The test verification data shall contain, at a minimum, all pertinent original data logs and documentation that the test sample preparation, test set up...
Judd, W J; Barnes, B A; Steiner, E A; Oberman, H A; Averill, D B; Butch, S H
1986-01-01
Direct antiglobulin tests (DATs) using anti-IgG were performed on 65,049 blood samples from prospective transfusion recipients; 3570 tests (5.49%) were positive. Using criteria published previously (primarily excluding patients not transfused within the preceding 14 days), 778 samples from other than neonatal patients were selected for further evaluation. Eluates that did not react were obtained on 518 (66.6%) of these samples. Warm-reactive autoantibodies were apparent in 192 eluates, while 16 contained drug-related antibodies, anti-A or anti-B from prior transfusion with ABO mismatched blood components, or anti-D passively acquired from immune serum globulin. Fifty-two eluates contained alloantibodies; however, in only six of these cases did the corresponding serum lack unexpected alloantibodies, as determined by routine pretransfusion studies. Three additional weakly reactive clinically significant alloantibodies were detected solely through additional serum tests performed on DAT-positive samples. On the basis of these findings, the DAT had a low predictive value when used to detect the early manifestations of an immune response to recently transfused red cells. Elimination of the autocontrol from routine pretransfusion testing, therefore, carries minimal risk to patients yet will undoubtedly contribute to the containment of health care costs. Moreover, the risk is lower than that associated with the elimination of the antiglobulin crossmatch.
Analyzer for measuring gas contained in the pore space of rocks
NASA Astrophysics Data System (ADS)
Kudasik, Mateusz; Skoczylas, Norbert
2017-10-01
In the present paper, the authors discussed the functioning of their own analyzer for measuring gas contained in the pore space of high strength rocks. A sample is placed inside a hermetic measuring chamber, and then undergoes impact milling as a result of colliding with the vibrating blade of a knife which is rotationally driven by a high-speed brushless electric motor. The measuring chamber is equipped with all the necessary sensors, i.e. gas, pressure, and temperature sensors. Trial tests involving the comminution of dolomite and anhydrite samples demonstrated that the constructed device is able to break up rocks into grains so fine that they are measured in single microns, and the sensors used in the construction ensure balancing of the released gas. The tests of the analyzer showed that the metrological concept behind it, together with the way it was built, make it fit for measurements of the content and composition of selected gases from the rock pore space. On the basis of the conducted tests of balancing the gases contained in the two samples, it was stated that the gas content of Sample no. 1 was (0.055 ± 0.002) cm3 g-1, and Sample no. 2 contained gas at atmospheric pressure, composed mostly of air.
NEA Multi-Chamber Sample Return Container with Hermetic Sealing
NASA Technical Reports Server (NTRS)
Rafeek, Shaheed; Kong, Kin Yuen; Sadick, Shazad; Porter, Christopher C.
2000-01-01
A sample return container is being developed by Honeybee Robotics to receive samples from a derivative of the Champollion/ST4 Sample Acquisition and Transfer Mechanism or other samplers such as the 'Touch and Go' Surface Sampler (TGSS), and then hermetically seal the samples for a sample return mission. The container is enclosed in a phase change material (PCM) chamber to prevent phase change during return and re-entry to earth. This container is designed to operate passively with no motors and actuators. Using the rotation axis of the TGSS sampler for interfacing, transferring and sealing samples, the container consumes no electrical power and therefore minimizes sample temperature change. The circular container houses multiple isolated canisters, which will be sealed individually for samples acquired from different sites or depths. The TGSS based sampler indexes each canister to the sample transfer position, below the index interface for sample transfer. After sample transfer is completed, the sampler indexes a seal carrier, which lines up seals with the openings of the canisters. The sampler moves to the sealing interface and seals the sample canisters one by one. The sealing interface can be designed to work with C-seals, knife edge seals and cup seals. This sample return container is being developed by Honeybee Robotics in collaboration with the JPL Exploration Technology program. A breadboard system of the sample return container has been recently completed and tested. Additional information is contained in the original extended abstract.
It's Time to Develop a New "Draft Test Protocol" for a Mars Sample Return Mission (or Two....)
NASA Astrophysics Data System (ADS)
Rummel, J. D.
2018-04-01
A Mars Sample Return (MSR) will involve analysis of those samples in containment, including their safe receiving, handling, testing, and archiving. With an MSR planned for the end of the next decade, it is time to update the existing MSR protocol.
GICHD mine dog testing project - soil sample results #4.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnett, James L.; Phelan, James M.; Archuleta, Luisa M.
2003-08-01
A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan and Bosnia containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performancemore » and seasonal weather conditions. This report documents the analytical chemical methods and results from the fourth batch of soils received. This batch contained samples from Kharga, Afghanistan collected in April 2003 and Sarajevo, Bosnia collected in May 2003.« less
Winters, W.J.
1999-01-01
As part of an ongoing laboratory study, preliminary acoustic, strength, and hydraulic conductivity results are presented from a suite of tests conducted on four natural-gas-hydrate-containing samples from the Mackenzie Delta JAPEX/JNOC/GSC Mallik 2L-38 gas hydrate research well. The gas hydrate samples were preserved in pressure vessels during transport from the Northwest Territories to Woods Hole, Massachusetts, where multistep tests were performed using GHASTLI (Gas Hydrate And Sediment Test Laboratory Instrument), which recreates pressure and temperature conditions that are stable for gas hydrate. Properties and changes in sediment behaviour were measured before, during, and after controlled gas hydrate dissociation. Significant amounts of gas hydrate occupied the sample pores and substantially increased acoustic velocity and shear strength.
LeBlanc, Denis R.; Vroblesky, Don A.
2008-01-01
Laboratory and field tests were conducted at Camp Edwards on the Massachusetts Military Reservation on Cape Cod to examine the utility of passive diffusion sampling for long-term monitoring of concentrations of perchlorate and explosive compounds in ground water. The diffusion samplers were constructed of 1-inch-diameter rigid, porous polyethylene tubing. The results of laboratory tests in which diffusion samplers were submerged in containers filled with ground water containing perchlorate, RDX (hexahydro-1,3,5-trinitro-1,3,5-triazine), and HMX (octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine) indicate that concentrations inside the diffusion samplers equilibrated with concentrations in the containers within the 19-day-long test period. Field tests of the diffusion samplers were conducted in 15 wells constructed of 2- or 2.5-inch-diameter polyvinyl chloride pipe with 10-foot-long slotted screens. Concentrations of perchlorate, RDX, and HMX in the diffusion samplers placed in the wells for 42 to 52 days were compared to concentrations in samples collected by low-flow pumped sampling from 53 days before to 109 days after retrieval of the diffusion samples. The results of the field tests indicate generally good agreement between the pumped and diffusion samples for concentrations of perchlorate, RDX, and HMX. The concentration differences indicate no systematic bias related to contaminant type or concentration levels.
Analysis of particulates on tape lift samples
NASA Astrophysics Data System (ADS)
Moision, Robert M.; Chaney, John A.; Panetta, Chris J.; Liu, De-Ling
2014-09-01
Particle counts on tape lift samples taken from a hardware surface exceeded threshold requirements in six successive tests despite repeated cleaning of the surface. Subsequent analysis of the particle size distributions of the failed tests revealed that the handling and processing of the tape lift samples may have played a role in the test failures. In order to explore plausible causes for the observed size distribution anomalies, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) were employed to perform chemical analysis on collected particulates. SEM/EDX identified Na and S containing particles on the hardware samples in a size range identified as being responsible for the test failures. ToF-SIMS was employed to further examine the Na and S containing particulates and identified the molecular signature of sodium alkylbenzene sulfonates, a common surfactant used in industrial detergent. The root cause investigation suggests that the tape lift test failures originated from detergent residue left behind on the glass slides used to mount and transport the tape following sampling and not from the hardware surface.
9 CFR 114.17 - Rebottling of biological products.
Code of Federal Regulations, 2011 CFR
2011-01-01
... section. (a) All or part of a serial which has not left the licensed establishment may be aseptically returned to the mixing tank, thoroughly mixed, and rebottled in new final containers. (b) The rebottled...) Required purity tests for final container samples of the product shall be conducted on new samples selected...
9 CFR 114.17 - Rebottling of biological products.
Code of Federal Regulations, 2010 CFR
2010-01-01
... section. (a) All or part of a serial which has not left the licensed establishment may be aseptically returned to the mixing tank, thoroughly mixed, and rebottled in new final containers. (b) The rebottled...) Required purity tests for final container samples of the product shall be conducted on new samples selected...
Thaipadungpanit, Janjira; Wuthiekanun, Vanaporn; Chantratita, Narisara; Yimsamran, Surapon; Amornchai, Premjit; Boonsilp, Siriphan; Maneeboonyang, Wanchai; Tharnpoophasiam, Prapin; Saiprom, Natnaree; Mahakunkijcharoen, Yuvadee; Day, Nicholas P J; Singhasivanon, Pratap; Peacock, Sharon J; Limmathurotsakul, Direk
2013-10-01
Floodwater samples (N = 110) collected during the 2011 Bangkok floods were tested for Leptospira using culture and polymerase chain reaction (PCR); 65 samples were PCR-positive for putatively non-pathogenic Leptospira species, 1 sample contained a putatively pathogenic Leptospira, and 6 samples contained Leptospira clustering phylogenetically with the intermediate group. The low prevalence of pathogenic and intermediate Leptospira in floodwater was consistent with the low number of human leptospirosis cases reported to the Bureau of Epidemiology in Thailand. This study provides baseline information on environmental Leptospira in Bangkok together with a set of laboratory tests that could be readily deployed in the event of future flooding.
ANALYTICAL METHOD DEVELOPMENTS TO SUPPORT PARTITIONING INTERWELL TRACER TESTING
Partitioning Interwell Tracer Testing (PITT) uses alcohol tracer compounds in estimating subsurface contamination from non-polar pollutants. PITT uses the analysis of water samples for various alcohols as part of the overall measurement process. The water samples may contain many...
NASA Astrophysics Data System (ADS)
Lindstrom, D.; Allen, C.
One of the strong scientific reasons for returning samples from Mars is to search for evidence of current or past life in the samples. Because of the remote possibility that the samples may contain life forms that are hazardous to the terrestrial biosphere, the National Research Council has recommended that all samples returned from Mars be kept under strict biological containment until tests show that they can safely be released to other laboratories. It is possible that Mars samples may contain only scarce or subtle traces of life or prebiotic chemistry that could readily be overwhelmed by terrestrial contamination. Thus, the facilities used to contain, process, and analyze samples from Mars must have a combination of high-level biocontainment and organic / inorganic chemical cleanliness that is unprecedented. We have been conducting feasibility studies and developing designs for a facility that would be at least as capable as current maximum containment BSL-4 (BioSafety Level 4) laboratories, while simultaneously maintaining cleanliness levels exceeding those of the cleanest electronics manufacturing labs. Unique requirements for the processing of Mars samples have inspired a program to develop handling techniques that are much more precise and reliable than the approach (currently used for lunar samples) of employing gloved human hands in nitrogen-filled gloveboxes. Individual samples from Mars are expected to be much smaller than lunar samples, the total mass of samples returned by each mission being 0.5- 1 kg, compared with many tens of kg of lunar samples returned by each of the six Apollo missions. Smaller samp les require much more of the processing to be done under microscopic observation. In addition, the requirements for cleanliness and high-level containment would be difficult to satisfy while using traditional gloveboxes. JSC has constructed a laboratory to test concepts and technologies important to future sample curation. The Advanced Curation Laboratory includes a new- generation glovebox equipped with a robotic arm to evaluate the usability of robotic and teleoperated systems to perform curatorial tasks. The laboratory also contains equipment for precision cleaning and the measurement of trace organic contamination.
Suitability of selected free-gas and dissolved-gas sampling containers for carbon isotopic analysis.
Eby, P; Gibson, J J; Yi, Y
2015-07-15
Storage trials were conducted for 2 to 3 months using a hydrocarbon and carbon dioxide gas mixture with known carbon isotopic composition to simulate typical hold times for gas samples prior to isotopic analysis. A range of containers (both pierced and unpierced) was periodically sampled to test for δ(13)C isotopic fractionation. Seventeen containers were tested for free-gas storage (20°C, 1 atm pressure) and 7 containers were tested for dissolved-gas storage, the latter prepared by bubbling free gas through tap water until saturated (20°C, 1 atm) and then preserved to avoid biological activity by acidifying to pH 2 with phosphoric acid and stored in the dark at 5°C. Samples were extracted using valves or by piercing septa, and then introduced into an isotope ratio mass spectrometer for compound-specific δ(13)C measurements. For free gas, stainless steel canisters and crimp-top glass serum bottles with butyl septa were most effective at preventing isotopic fractionation (pierced and unpierced), whereas silicone and PTFE-butyl septa allowed significant isotopic fractionation. FlexFoil and Tedlar bags were found to be effective only for storage of up to 1 month. For dissolved gas, crimp-top glass serum bottles with butyl septa were again effective, whereas silicone and PTFE-butyl were not. FlexFoil bags were reliable for up to 2 months. Our results suggest a range of preferred containers as well as several that did not perform very well for isotopic analysis. Overall, the results help establish better QA/QC procedures to avoid isotopic fractionation when storing environmental gas samples. Recommended containers for air transportation include steel canisters and glass serum bottles with butyl septa (pierced and unpierced). Copyright © 2015 John Wiley & Sons, Ltd.
Method and apparatus for measuring enrichment of UF6
Hill, Thomas Roy [Santa Fe, NM; Ianakiev, Kiril Dimitrov [Los Alamos, NM
2011-06-07
A system and method are disclosed for determining the enrichment of .sup.235U in Uranium Hexafluoride (UF6) utilizing synthesized X-rays which are directed at a container test zone containing a sample of UF6. A detector placed behind the container test zone then detects and counts the X-rays which pass through the container and the UF6. In order to determine the portion of the attenuation due to the UF6 gas alone, this count rate may then be compared to a calibration count rate of X-rays passing through a calibration test zone which contains a vacuum, the test zone having experienced substantially similar environmental conditions as the actual test zone. Alternatively, X-rays of two differing energy levels may be alternately directed at the container, where either the container or the UF6 has a high sensitivity to the difference in the energy levels, and the other having a low sensitivity.
Ahmed, W; Hodgers, L; Sidhu, J P S; Toze, S
2012-01-01
In this study, the microbiological quality of household tap water samples fed from rainwater tanks was assessed by monitoring the numbers of Escherichia coli bacteria and enterococci from 24 households in Southeast Queensland (SEQ), Australia. Quantitative PCR (qPCR) was also used for the quantitative detection of zoonotic pathogens in water samples from rainwater tanks and connected household taps. The numbers of zoonotic pathogens were also estimated in fecal samples from possums and various species of birds by using qPCR, as possums and birds are considered to be the potential sources of fecal contamination in roof-harvested rainwater (RHRW). Among the 24 households, 63% of rainwater tank and 58% of connected household tap water (CHTW) samples contained E. coli and exceeded Australian drinking water guidelines of <1 CFU E. coli per 100 ml water. Similarly, 92% of rainwater tanks and 83% of CHTW samples also contained enterococci. In all, 21%, 4%, and 13% of rainwater tank samples contained Campylobacter spp., Salmonella spp., and Giardia lamblia, respectively. Similarly, 21% of rainwater tank and 13% of CHTW samples contained Campylobacter spp. and G. lamblia, respectively. The number of E. coli (P = 0.78), Enterococcus (P = 0.64), Campylobacter (P = 0.44), and G. lamblia (P = 0.50) cells in rainwater tanks did not differ significantly from the numbers observed in the CHTW samples. Among the 40 possum fecal samples tested, Campylobacter spp., Cryptosporidium parvum, and G. lamblia were detected in 60%, 13%, and 30% of samples, respectively. Among the 38 bird fecal samples tested, Campylobacter spp., Salmonella spp., C. parvum, and G. lamblia were detected in 24%, 11%, 5%, and 13% of the samples, respectively. Household tap water samples fed from rainwater tanks tested in the study appeared to be highly variable. Regular cleaning of roofs and gutters, along with pruning of overhanging tree branches, might also prove effective in reducing animal fecal contamination of rainwater tanks.
Hodgers, L.; Sidhu, J. P. S.; Toze, S.
2012-01-01
In this study, the microbiological quality of household tap water samples fed from rainwater tanks was assessed by monitoring the numbers of Escherichia coli bacteria and enterococci from 24 households in Southeast Queensland (SEQ), Australia. Quantitative PCR (qPCR) was also used for the quantitative detection of zoonotic pathogens in water samples from rainwater tanks and connected household taps. The numbers of zoonotic pathogens were also estimated in fecal samples from possums and various species of birds by using qPCR, as possums and birds are considered to be the potential sources of fecal contamination in roof-harvested rainwater (RHRW). Among the 24 households, 63% of rainwater tank and 58% of connected household tap water (CHTW) samples contained E. coli and exceeded Australian drinking water guidelines of <1 CFU E. coli per 100 ml water. Similarly, 92% of rainwater tanks and 83% of CHTW samples also contained enterococci. In all, 21%, 4%, and 13% of rainwater tank samples contained Campylobacter spp., Salmonella spp., and Giardia lamblia, respectively. Similarly, 21% of rainwater tank and 13% of CHTW samples contained Campylobacter spp. and G. lamblia, respectively. The number of E. coli (P = 0.78), Enterococcus (P = 0.64), Campylobacter (P = 0.44), and G. lamblia (P = 0.50) cells in rainwater tanks did not differ significantly from the numbers observed in the CHTW samples. Among the 40 possum fecal samples tested, Campylobacter spp., Cryptosporidium parvum, and G. lamblia were detected in 60%, 13%, and 30% of samples, respectively. Among the 38 bird fecal samples tested, Campylobacter spp., Salmonella spp., C. parvum, and G. lamblia were detected in 24%, 11%, 5%, and 13% of the samples, respectively. Household tap water samples fed from rainwater tanks tested in the study appeared to be highly variable. Regular cleaning of roofs and gutters, along with pruning of overhanging tree branches, might also prove effective in reducing animal fecal contamination of rainwater tanks. PMID:22020514
Passive Earth Entry Vehicle Landing Test
NASA Technical Reports Server (NTRS)
Kellas, Sotiris
2017-01-01
Two full-scale passive Earth Entry Vehicles (EEV) with realistic structure, surrogate sample container, and surrogate Thermal Protection System (TPS) were built at NASA Langley Research Center (LaRC) and tested at the Utah Test and Training Range (UTTR). The main test objective was to demonstrate structural integrity and investigate possible impact response deviations of the realistic vehicle as compared to rigid penetrometer responses. With the exception of the surrogate TPS and minor structural differences in the back shell construction, the two test vehicles were identical in geometry and both utilized the Integrated Composite Stiffener Structure (ICoSS) structural concept in the forward shell. The ICoSS concept is a lightweight and highly adaptable composite concept developed at NASA LaRC specifically for entry vehicle TPS carrier structures. The instrumented test vehicles were released from a helicopter approximately 400 m above ground. The drop height was selected such that at least 98% of the vehicles terminal velocity would be achieved. While drop tests of spherical penetrometers and a low fidelity aerodynamic EEV model were conducted at UTTR in 1998 and 2000, this was the first time a passive EEV with flight-like structure, surrogate TPS, and sample container was tested at UTTR for the purpose of complete structural system validation. Test results showed that at a landing vertical speed of approximately 30 m/s, the test vehicle maintained structural integrity and enough rigidity to penetrate the sandy clay surface thus attenuating the landing load, as measured at the vehicle CG, to less than 600 g. This measured deceleration was found to be in family with rigid penetrometer test data from the 1998 and 2000 test campaigns. Design implications of vehicle structure/soil interaction with respect to sample container and sample survivability are briefly discussed.
Mobile/Modular BSL-4 Facilities for Meeting Restricted Earth Return Containment Requirements
NASA Technical Reports Server (NTRS)
Calaway, M. J.; McCubbin, F. M.; Allton, J. H.; Zeigler, R. A.; Pace, L. F.
2017-01-01
NASA robotic sample return missions designated Category V Restricted Earth Return by the NASA Planetary Protection Office require sample containment and biohazard testing in a receiving laboratory as directed by NASA Procedural Requirement (NPR) 8020.12D - ensuring the preservation and protection of Earth and the sample. Currently, NPR 8020.12D classifies Restricted Earth Return for robotic sample return missions from Mars, Europa, and Enceladus with the caveat that future proposed mission locations could be added or restrictions lifted on a case by case basis as scientific knowledge and understanding of biohazards progresses. Since the 1960s, sample containment from an unknown extraterrestrial biohazard have been related to the highest containment standards and protocols known to modern science. Today, Biosafety Level (BSL) 4 standards and protocols are used to study the most dangerous high-risk diseases and unknown biological agents on Earth. Over 30 BSL-4 facilities have been constructed worldwide with 12 residing in the United States; of theses, 8 are operational. In the last two decades, these brick and mortar facilities have cost in the hundreds of millions of dollars dependent on the facility requirements and size. Previous mission concept studies for constructing a NASA sample receiving facility with an integrated BSL-4 quarantine and biohazard testing facility have also been estimated in the hundreds of millions of dollars. As an alternative option, we have recently conducted an initial trade study for constructing a mobile and/or modular sample containment laboratory that would meet all BSL-4 and planetary protection standards and protocols at a faction of the cost. Mobile and modular BSL-2 and 3 facilities have been successfully constructed and deployed world-wide for government testing of pathogens and pharmaceutical production. Our study showed that a modular BSL-4 construction could result in approximately 90% cost reduction when compared to traditional construction methods without compromising the preservation of the sample or Earth.
Test/QA Plan for Verification of Coliform Detection Technologies for Drinking Water
The coliform detection technologies to be tested use chromatogenic and fluorogenic growth media to detect coliforms and E. coli based on the enzymatic activity of these organisms. The systems consist of single-use sample containers that contain pre-measured reagents and can be u...
Cleveland, Laverne; Little, Edward E.; Petty, Jimmie D.; Johnson, B. Thomas; Lebo, Jon A.; Orazio, Carl E.; Dionne, Jane
1997-01-01
Eight whole sediment samples from Antarctica (four from Winter Quarters Bay and four from McMurdo Sound) were toxicologically and chemically evaluated. Also, the influence of ultraviolet radiation on the toxicity and bioavailability of contaminants associated with the sediment samples was assessed. The evaluations were accomplished by use of a 10-day whole sediment test with Leptocheirus plumulosus, Microtox®, Mutatox® and semipermeable membrane devices (SPMDs). Winter Quarters Bay sediments contained about 250 ng g−1 (dry weight) total PCBs and 20 μg g−1 total PAHs. These sediments elicited toxicity in the Microtox test and avoidance and inhibited burrowing in the L. plumulosus test. The McMurdo Sound sediment samples contained only trace amounts of PCBs and no PAHs, and were less toxic in both the L. plumulosus and Microtox tests compared to the Winter Quarters Bay sediments. The sediments from McMurdo Sound apparently contained some unidentified substance which was photolytically modified to a more toxic form. The photolytic modification of sediment-associated contaminants, coupled with the polar ozone hole and increased incidence of ultraviolet radiation could significantly increase hazards to Antarctic marine life.
Chlamydia and gonorrhoea contamination of clinic surfaces.
Lewis, Natasha; Dube, Gail; Carter, Christine; Pitt, Rachel; Alexander, Sarah; Ison, Catherine A; Harding, Jan; Brown, Louise; Fryer, John; Hodson, James; Ross, Jonathan
2012-10-01
Nucleic acid amplification tests, with their ability to detect very small amounts of nucleic acid, have become the principle diagnostic tests for Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (GC) in many sexual health clinics. The aim of this study was to investigate the extent of surface contamination with CT and GC within a city centre sexual health clinic and to evaluate the potential for contamination of containers used for the collection of self-taken swabs. Surface contamination with CT and GC was assessed by systematically sampling 154 different sites within one clinic using transcription-mediated amplification (TMA), quantitative PCR and culture. The caps of containers used by patients to collect self-taken samples were also tested for CT and GC using TMA. Of the 154 sites sampled, 20 (13.0%) tested positive on TMA. Of these, five (3.2%) were positive for CT alone, 11 (7.1%) for GC alone and four (2.6%) for both CT and GC. The proportion of GC TMA-positive test results differed by gender, with 11 (18.3%) positive results from the male patient clinic area compared with one (1.6%) from the female area (p=0.002). Positive samples were obtained from a variety of locations in the clinic, but the patient toilets were more likely to be contaminated than examination rooms (p=0.015). Quantitative PCR and culture assays were negative for all samples. 46 caps of the containers used for self-taken swabs were negative for both CT and GC on TMA testing. Surface contamination with chlamydial and gonococcal rRNA can occur within sexual health clinics, but the quantity of nucleic acid detected is low and infection risk to patients and staff is small. There remains a potential risk of contamination of patient samples leading to false-positive results.
Yoon, Seung-Yil; Sagi, Hemi; Goldhammer, Craig; Li, Lei
2012-01-01
Container closure integrity (CCI) is a critical factor to ensure that product sterility is maintained over its entire shelf life. Assuring the CCI during container closure (C/C) system qualification, routine manufacturing and stability is important. FDA guidance also encourages industry to develop a CCI physical testing method in lieu of sterility testing in a stability program. A mass extraction system has been developed to check CCI for a variety of container closure systems such as vials, syringes, and cartridges. Various types of defects (e.g., glass micropipette, laser drill, wire) were created and used to demonstrate a detection limit. Leakage, detected as mass flow in this study, changes as a function of defect length and diameter. Therefore, the morphology of defects has been examined in detail with fluid theories. This study demonstrated that a mass extraction system was able to distinguish between intact samples and samples with 2 μm defects reliably when the defect was exposed to air, water, placebo, or drug product (3 mg/mL concentration) solution. Also, it has been verified that the method was robust, and capable of determining the acceptance limit using 3σ for syringes and 6σ for vials. Sterile products must maintain their sterility over their entire shelf life. Container closure systems such as those found in syringes and vials provide a seal between rubber and glass containers. This seal must be ensured to maintain product sterility. A mass extraction system has been developed to check container closure integrity for a variety of container closure systems such as vials, syringes, and cartridges. In order to demonstrate the method's capability, various types of defects (e.g., glass micropipette, laser drill, wire) were created in syringes and vials and were tested. This study demonstrated that a mass extraction system was able to distinguish between intact samples and samples with 2 μm defects reliably when the defect was exposed to air, water, placebo, or drug product (3 mg/mL concentration) solution. Also, it was verified that the method showed consistent results, and was able to determine the acceptance limit using 3σ for syringes and 6σ for vials.
The results of gas permeability and leak testing during active soil-gas sampling at Hal’s Chevron LUST Site in Green River, Utah are presented. This study was conducted to support development of a passive soil-gas sampling method. Gas mixtures containing helium and methane were...
Serological Detection of Viral Infections in Captive Wild Cats from Costa Rica
Blanco, Kinndle; Peña, Roberto; Hernández, Carmen; Jiménez, Mauricio; Araya, Luis Nazario; Romero, Juan José; Dolz, Gaby
2011-01-01
Serum samples from a total of 44 wildcats, 28 margays (Leopardus wiedii), 10 ocelots (Leopardus pardalis), four jaguaroundis (Herpailurus yaguaroundi), one oncilla (Leopardus tigrina), and one jaguar (Panthera onca) were obtained between January 2001 and August 2002 from the Profelis Centre for rehabilitation of wild felids, located in the northwestern region of Costa Rica. Forty three samples were tested for antibodies against feline immunodeficiency virus (FIV) and p27 antigen of feline leukemia virus (FeLV), 42 samples for antibodies against feline parvovirus (FPV), and 30 for antibodies against feline calicivirus (FCV). None of the samples contained detectable antibodies against FIV or p27 antigen of FeLV, all samples contained antibodies against FPV, and one sample contained antibodies against FCV. PMID:21547230
Serological detection of viral infections in captive wild cats from costa rica.
Blanco, Kinndle; Peña, Roberto; Hernández, Carmen; Jiménez, Mauricio; Araya, Luis Nazario; Romero, Juan José; Dolz, Gaby
2011-04-03
Serum samples from a total of 44 wildcats, 28 margays (Leopardus wiedii), 10 ocelots (Leopardus pardalis), four jaguaroundis (Herpailurus yaguaroundi), one oncilla (Leopardus tigrina), and one jaguar (Panthera onca) were obtained between January 2001 and August 2002 from the Profelis Centre for rehabilitation of wild felids, located in the northwestern region of Costa Rica. Forty three samples were tested for antibodies against feline immunodeficiency virus (FIV) and p27 antigen of feline leukemia virus (FeLV), 42 samples for antibodies against feline parvovirus (FPV), and 30 for antibodies against feline calicivirus (FCV). None of the samples contained detectable antibodies against FIV or p27 antigen of FeLV, all samples contained antibodies against FPV, and one sample contained antibodies against FCV.
Dong, Bing; Song, Yu; Fan, Wenjia; Zhu, Ying
2010-11-01
To study the homogeneity and stability of arsenic in quality controlling cosmetic samples. Arsenic was determined by atomic fluorescence spectrophotometric method. The t-test and F-test were used to evaluate the significant difference of the within-bottle and between-bottle results with three batches. The RSDs of arsenic obtained in different time were compared with the relative expanding uncertainties to evaluate the stability. Average and variance of within-bottle and between-bottle results of arsenic were not different significantly. The RSDs of Arsenic were less than the relative expanding uncertainties. Quality controlling cosmetic samples containing arsenic were considered homogeneous and stable.
Chorionic villus sampling - slideshow
... the embryonic sac. Surgeons sample these projections for genetic testing because they contain the same genetic material as a fetus. If you are at ... 12 weeks gestation to find out a fetus' genetic makeup. Review Date 10/4/2016 ... Prenatal Testing A.D.A.M., Inc. is accredited by ...
Stark, Peter C.; Kuske, Cheryl R.; Mullen, Kenneth I.
2002-01-01
A method for quantitating dsDNA in an aqueous sample solution containing an unknown amount of dsDNA. A first aqueous test solution containing a known amount of a fluorescent dye-dsDNA complex and at least one fluorescence-attenutating contaminant is prepared. The fluorescence intensity of the test solution is measured. The first test solution is diluted by a known amount to provide a second test solution having a known concentration of dsDNA. The fluorescence intensity of the second test solution is measured. Additional diluted test solutions are similarly prepared until a sufficiently dilute test solution having a known amount of dsDNA is prepared that has a fluorescence intensity that is not attenuated upon further dilution. The value of the maximum absorbance of this solution between 200-900 nanometers (nm), referred to herein as the threshold absorbance, is measured. A sample solution having an unknown amount of dsDNA and an absorbance identical to that of the sufficiently dilute test solution at the same chosen wavelength is prepared. Dye is then added to the sample solution to form the fluorescent dye-dsDNA-complex, after which the fluorescence intensity of the sample solution is measured and the quantity of dsDNA in the sample solution is determined. Once the threshold absorbance of a sample solution obtained from a particular environment has been determined, any similarly prepared sample solution taken from a similar environment and having the same value for the threshold absorbance can be quantified for dsDNA by adding a large excess of dye to the sample solution and measuring its fluorescence intensity.
Technical note: Headspace analysis of explosive compounds using a novel sampling chamber.
DeGreeff, Lauryn; Rogers, Duane A; Katilie, Christopher; Johnson, Kevin; Rose-Pehrsson, Susan
2015-03-01
The development of instruments and methods for explosive vapor detection is a continually evolving field of interest. A thorough understanding of the characteristic vapor signatures of explosive material is imperative for the development and testing of new and current detectors. In this research a headspace sampling chamber was designed to contain explosive materials for the controlled, reproducible sampling and characterization of vapors associated with these materials. In a detonation test, the chamber was shown to contain an explosion equivalent to three grams of trinitrotoluene (TNT) without damage to the chamber. The efficacy of the chamber in controlled headspace sampling was evaluated in laboratory tests with bulk explosive materials. Small quantities of TNT, triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD) were separately placed in the sampling chamber, and the headspace of each material was analyzed by gas chromatography/mass spectrometry (GC/MS) with online cryogenic trapping to yield characteristic vapor signatures for each explosive compound. Chamber sampling conditions, temperature and sampling time, were varied to demonstrate suitability for precise headspace analysis. Published by Elsevier Ireland Ltd.
Slinger, Robert; Lau, Kimberley; Slinger, Michael; Moldovan, Ioana; Chan, Francis
2017-03-23
Typical enteropathogenic Escherichia coli (t-EPEC) are known to cause diarrhea in children but it is uncertain whether atypical EPEC (a-EPEC) do, since a-EPEC lack the bundle-forming pilus (bfp) gene that encodes a key adherence factor in t-EPEC. In culture-based studies of a-EPEC, the presence of another adherence factor, called EHEC factor for adherence/lymphocyte activation inhibitor (efa1/lifA), was strongly associated with diarrhea. Since a-EPEC culture is not feasible in clinical laboratories, we designed an efa1/lifA quantitative PCR assay and examined whether the presence of efa1/lifA was associated with higher a-EPEC bacterial loads in pediatric diarrheal stool samples. Fecal samples from children with diarrhea were tested by qPCR for EPEC (presence of eae gene) and for shiga toxin genes to exclude enterohemorrhagic E. coli, which also contain the eae gene. EPEC containing samples were then tested for the bundle-forming pilus gene found in t-EPEC and efa1/lifA. The eae gene quantity in efa1/lifA-positive and negative samples was compared. Thirty-nine of 320 (12%) fecal samples tested positive for EPEC and 38/39 (97%) contained a-EPEC. The efa1/lifA gene was detected in 16/38 (42%) a-EPEC samples. The median eae concentration for efa1/lifA positive samples was significantly higher than for efa1/lifA negative samples (median 16,745 vs. 1183 copies/µL, respectively, p = 0.006). Atypical enteropathogenic E. coli-positive diarrheal stool samples containing the efa1/lifA gene had significantly higher bacterial loads than samples lacking this gene. This supports the idea that efa1/lifA contributes to diarrheal pathogenesis and suggests that, in EPEC-positive samples, efa/lifA may be a useful additional molecular biomarker.
Mose, Kristian F; Andersen, Klaus E; Christensen, Lars Porskjaer
2012-04-01
Patch test preparations of volatile substances may evaporate during storage, thereby giving rise to reduced patch test concentrations. To investigate the stability of selected acrylates/methacrylates and fragrance allergens in three different test chambers under different storage conditions. Petrolatum samples of methyl methacrylate (MMA), 2-hydroxyethyl methacrylate (2-HEMA), 2-hydroxypropyl acrylate (2-HPA), cinnamal and eugenol in patch test concentrations were stored in three different test chambers (IQ chamber™, IQ Ultimate™, and Van der Bend® transport container) at room temperature and in a refrigerator. The samples were analysed in triplicate with high-performance liquid chromatography. The decrease in concentration was substantial for all five allergens under both storage conditions in IQ chamber™ and IQ Ultimate™, with the exception of 2-HEMA during storage in the refrigerator. For these two chamber systems, the contact allergen concentration dropped below the stability limit in the following order: MMA, cinnamal, 2-HPA, eugenol, and 2-HEMA. In the Van der Bend® transport container, the contact allergens exhibited acceptable stability under both storage conditions, whereas MMA and 2-HPA required cool storage for maintenance of the limit. The Van der Bend® transport container was the best device for storage of samples of volatile contact allergens. © 2012 John Wiley & Sons A/S.
McMahan, Lanakila; Grunden, Amy M; Devine, Anthony A; Sobsey, Mark D
2012-04-15
The sensitivity and specificity of the H(2)S test to detect fecal bacteria in water has been variable and uncertain in previous studies, partly due to its presence-absence results. Furthermore, in groundwater samples false-positive results have been reported, with H(2)S-positive samples containing no fecal coliforms or Escherichia coli. False-negative results also have been reported in other studies, with H(2)S-negative samples found to contain E. coli. Using biochemical and molecular methods and a novel quantitative test format, this research identified the types and numbers of microbial community members present in natural water samples, including fecal indicators and pathogens as well as other bacteria. Representative water sources tested in this study included cistern rainwater, a protected lake, and wells in agricultural and forest settings. Samples from quantitative H(2)S tests of water were further cultured for fecal bacteria by spread plating onto the selective media for detection and isolation of Aeromonas spp., E. coli, Clostridium spp., H(2)S-producers, and species of Salmonella and Shigella. Isolates were then tested for H(2)S production, and identified to the genus and species level using biochemical methods. Terminal Restriction Fragment Length Polymorphisms (TRFLP) was the molecular method employed to quantitatively characterize microbial community diversity. Overall, it was shown that water samples testing positive for H(2)S bacteria also had bacteria of likely fecal origin and waters containing fecal pathogens also were positive for H(2)S bacteria. Of the microorganisms isolated from natural water, greater than 70 percent were identified using TRFLP analysis to reveal a relatively stable group of organisms whose community composition differed with water source and over time. These results further document the validity of the H(2)S test for detecting and quantifying fecal contamination of water. Copyright © 2011 Elsevier Ltd. All rights reserved.
Validating the Inactivation Effectiveness of Chemicals on Ebola Virus.
Haddock, Elaine; Feldmann, Friederike
2017-01-01
While viruses such as Ebola virus must be handled in high-containment laboratories, there remains the need to process virus-infected samples for downstream research testing. This processing often includes removal to lower containment areas and therefore requires assurance of complete viral inactivation within the sample before removal from high-containment. Here we describe methods for the removal of chemical reagents used in inactivation procedures, allowing for validation of the effectiveness of various inactivation protocols.
Prevalence of genetically modified rice, maize, and soy in Saudi food products.
Elsanhoty, Rafaat M; Al-Turki, A I; Ramadan, Mohamed Fawzy
2013-10-01
Qualitative and quantitative DNA-based methods were applied to detect genetically modified foods in samples from markets in the Kingdom of Saudi Arabia. Two hundred samples were collected from Al-Qassim, Riyadh, and Mahdina in 2009 and 2010. GMOScreen 35S and NOS test kits for the detection of genetically modified organism varieties in samples were used. The positive results obtained from GMOScreen 35S and NOS were identified using specific primer pairs. The results indicated that all rice samples gave negative results for the presence of 35S and NOS terminator. About 26 % of samples containing soybean were positive for 35S and NOS terminator and 44 % of samples containing maize were positive for the presence of 35S and/or NOS terminator. The results showed that 20.4 % of samples was positive for maize line Bt176, 8.8 % was positive for maize line Bt11, 8.8 % was positive for maize line T25, 5.9 % was positive for maize line MON 810, and 5.9 % was positive for StarLink maize. Twelve samples were shown to contain <3 % of genetically modified (GM) soy and 6 samples >10 % of GM soy. Four samples containing GM maize were shown to contain >5 % of GM maize MON 810. Four samples containing GM maize were shown to contain >1 % of StarLink maize. Establishing strong regulations and certified laboratories to monitor GM foods or crops in Saudi market is recommended.
Khoshkava, Vahid; Kamal, Musa R
2014-06-11
Polypropylene (PP) nanocomposites containing spray-dried cellulose nanocrystals (CNC), freeze-dried CNC, and spray-freeze-dried CNC (CNCSFD) were prepared via melt mixing in an internal batch mixer. Polarized light, scanning electron, and atomic force microscopy showed significantly better dispersion of CNCSFD in PP/CNC nanocomposites compared with the spray-dried and freeze-dried CNCs. Rheological measurements, including linear and nonlinear viscoelastic tests, were performed on PP/CNC samples. The microscopy results were supported by small-amplitude oscillatory shear tests, which showed substantial rises in the magnitudes of key rheological parameters of PP samples containing CNCSFD. Steady-shear results revealed a strong shear thinning behavior of PP samples containing CNCSFD. Moreover, PP melts containing CNCSFD exhibited a yield stress. The magnitude of the yield stress and the degree of shear thinning behavior increased with CNCSFD concentration. It was found that CNCSFD agglomerates with a weblike structure were more effective in modifying the rheological properties. This effect was attributed to better dispersion of the agglomerates with the weblike structure. Dynamic mechanical analysis showed considerable improvement in the modulus of samples containing CNCSFD agglomerates. The percolation mechanical model with modified volume percolation threshold and filler network strength values and the Halpin-Kardos model were used to fit the experimental results.
Examples of Data Analysis with SPSS-X.
ERIC Educational Resources Information Center
MacFarland, Thomas W.
Intended for classroom use only, these unpublished notes contain computer lessons on descriptive statistics using SPSS-X Release 3.0 for VAX/UNIX. Statistical measures covered include Chi-square analysis; Spearman's rank correlation coefficient; Student's t-test with two independent samples; Student's t-test with a paired sample; One-way analysis…
40 CFR 61.174 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Arsenic Emissions From Primary Copper Smelters § 61.174 Test methods and procedures. (a) To determine... converter arsenic charging rate as follows: (1) Collect daily grab samples of copper matte and any lead... determine the weight percent of inorganic arsenic contained in each sample. (3) Calculate the converter...
U.S. History: Grades 7-9. Revised Edition.
ERIC Educational Resources Information Center
Instructional Objectives Exchange, Los Angeles, CA.
Sixty-three behavioral objectives and related test items for United States history in grades seven through nine are presented. Each sample contains the objective, sample test items and directions, and criteria for judging the adequacy of student responses. Fourteen of the 15 categories are content oriented and presented chronologically: (1)…
Klump, S P; Allred, M C; MacDonald, J L; Ballam, J M
2001-01-01
Isoflavones are biologically active compounds occurring naturally in a variety of plants, with relatively high levels found in soybeans. Twelve laboratories participated in a collaborative study to determine the aglycon isoflavone content of 8 test samples of soy and foods containing soy. The analytical method for the determination of isoflavones incorporates a mild saponification step that reduces the number of analytes measured and permits quantitation versus commercially available, stable reference standards. Test samples were extracted at 65 degrees C with methanol-water (80 + 20), saponified with dilute sodium hydroxide solution, and analyzed by reversed-phase liquid chromatography with UV detection at 260 nm. Isoflavone results were reported as microg/aglycon/g or microg aglycon equivalents/g. The 8 test samples included 2 blind duplicates and 4 single test samples with total isoflavone concentrations ranging from approximately 50 to 3000 microg/g. Test samples of soy ingredients and products made with soy were distributed to collaborators with appropriate reference standards. Collaborators were asked to analyze test samples in duplicate on 2 separate days. The data were analyzed for individual isoflavone components, subtotals of daidzin-daidzein, glycitin-glycitein, and genistin-genistein, and total isoflavones. The relative standard deviation (RSD) for repeatability was 1.8-7.1%, and the RSD for reproducibility was 3.2-16.1% for total isoflavone values of 47-3099 microg/g.
Palamar, Joseph J; Salomone, Alberto; Vincenti, Marco; Cleland, Charles M
2016-04-01
Ecstasy (MDMA) in the US is commonly adulterated with other drugs, but research has not focused on purity of ecstasy since the phenomenon of "Molly" (ecstasy marketed as pure MDMA) arose in the US. We piloted a rapid electronic survey in 2015 to assess use of novel psychoactive substances (NPS) and other drugs among 679 nightclub/festival-attending young adults (age 18-25) in New York City. A quarter (26.1%) of the sample provided a hair sample to be analyzed for the presence of select synthetic cathinones ("bath salts") and some other NPS. Samples were analyzed using fully validated UHPLC-MS/MS methods. To examine consistency of self-report, analyses focused on the 48 participants with an analyzable hair sample who reported lifetime ecstasy/MDMA/Molly use. Half (50.0%) of the hair samples contained MDMA, 47.9% contained butylone, and 10.4% contained methylone. Of those who reported no lifetime use of "bath salts", stimulant NPS, or unknown pills or powders, about four out of ten (41.2%) tested positive for butylone, methylone, alpha-PVP, 5/6-APB, or 4-FA. Racial minorities were more likely to test positive for butylone or test positive for NPS after reporting no lifetime use. Frequent nightclub/festival attendance was the strongest predictor of testing positive for MDMA, butylone, or methylone. Results suggest that many ecstasy-using nightclub/festival attendees may be unintentionally using "bath salts" or other NPS. Prevention and harm reduction education is needed for this population and "drug checking" (e.g., pill testing) may be beneficial for those rejecting abstinence. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Palamar, Joseph J.; Salomone, Alberto; Vincenti, Marco; Cleland, Charles M.
2016-01-01
Background Ecstasy (MDMA) in the US is commonly adulterated with other drugs, but research has not focused on purity of ecstasy since the phenomenon of “Molly” (ecstasy marketed as pure MDMA) arose in the US. Methods We piloted a rapid electronic survey in 2015 to assess use of novel psychoactive substances (NPS) and other drugs among 679 nightclub/festival-attending young adults (age 18–25) in New York City. A quarter (26.1%) of the sample provided a hair sample to be analyzed for the presence of select synthetic cathinones (“bath salts”) and some other NPS. Samples were analyzed using fully validated UHPLC-MS/MS methods. To examine consistency of self-report, analyses focused on the 48 participants with an analyzable hair sample who reported lifetime ecstasy/MDMA/Molly use. Results Half (50.0%) of the hair samples contained MDMA, 47.9% contained butylone, and 10.4% contained methylone. Of those who reported no lifetime use of “bath salts”, stimulant NPS, or unknown pills or powders, about four out of ten (41.2%) tested positive for butylone, methylone, alpha-PVP, 5/6-APB, or 4-FA. Racial minorities were more likely to test positive for butylone or test positive for NPS after reporting no lifetime use. Frequent nightclub/festival attendance was the strongest predictor of testing positive for MDMA, butylone, or methylone. Discussion Results suggest that many ecstasy-using nightclub/festival attendees may be unintentionally using “bath salts” or other NPS. Prevention and harm reduction education is needed for this population and “drug checking” (e.g., pill testing) may be beneficial for those rejecting abstinence. PMID:26883685
Chang, David F; Hurley, Nikki; Mamalis, Nick; Whitman, Jeffrey
2018-03-27
The common practice of short-cycle sterilization for ophthalmic surgical instrumentation has come under increased regulatory scrutiny. This study was undertaken to evaluate the efficacy of short-cycle sterilization processing for consecutive same-day cataract procedures. Testing of specific sterilization processing methods by an independent medical device validation testing laboratory. Phaco handpieces from 3 separate manufacturers were tested along with appropriate biologic indicators and controls using 2 common steam sterilizers. A STATIM 2000 sterilizer (SciCan, Canonsburg, PA) with the STATIM metal cassette, and an AMSCO Century V116 pre-vacuum sterilizer (STERIS, Mentor, OH) using a Case Medical SteriTite container (Case Medical, South Hackensack, NJ) rigid container were tested using phaco tips and handpieces from 3 different manufacturers. Biological indicators were inoculated with highly resistant Geobacillus stearothermophilus, and each sterility verification test was performed in triplicate. Both wrapped and contained loads were tested with full dry cycles and a 7-day storage time to simulate prolonged storage. In adherence with the manufacturers' instructions for use (IFU), short cycles (3.0-3.5-minute exposure times) for unwrapped and contained loads were also tested after only 1 minute of dry time to simulate use on a consecutive case. Additional studies were performed to demonstrate whether any moisture present in the load containing phaco handpieces postprocessing was sterile and would affect the sterility of the contents after a 3-minute transit/storage time. This approximated the upper limit of time needed to transfer a containment device to the operating room. Presence or absence of microbial growth from cultured test samples. All inoculated test samples from both sterilizers were negative for growth of the target organism whether the full dry phase was interrupted or not. Pipetted postprocessing moisture samples and swabs of the handpieces were also negative for growth after a 3-minute transit/storage time. These studies support the use of unwrapped, short-cycle sterilization that adheres to the IFU of these 2 popular Food and Drug Administration-cleared sterilizers for sequential same-day cataract surgeries. A full drying phase is not necessary when the instruments are kept within the covered sterilizer containment device for prompt use on a sequential case. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Pathak, Prachi; Kumar, Ashu; Thavaselvam, Duraipandian
2017-07-11
Brucellosis is an important zoonotic disease caused by different Brucella species and human brucellosis is commonly prevalent in different states of India. Among various Brucella species, B. melitensis is most pathogenic to human and included as category B biothreat which can cause infection through aerosol, cut, wounds in skin and contact with infected animals. The diagnosis of human brucellosis is very important for proper treatment and management of disease as there is no vaccine available for human use. The present study was designed to clone, express and purify immunodominant recombinant omp2a (rOmp2a) porin protein of B. melitensis and to evaluate this new antigen candidate for specific serodiagnosis of human brucellosis by highly sensitive iELISA (indirect enzyme linked immunosorbent assay). Omp2a gene of B. melitensis 16 M strain was cloned and expressed in pET-SUMO expression system. The recombinant protein was purified under denaturing conditions using 8 M urea. The purified recombinant protein was confirmed by western blotting by reacting with anti-HIS antibody. The sero-reactivity of the recombinant protein was also checked by reacting with antisera of experimentally infected mice with B. melitensis 16 M at different time points. Serodiagnostic potential of recombinant porin antigen was tested against 185 clinical serum samples collected from regions endemic to brucellosis in southern part of India by iELISA. The samples were grouped into five groups. Group 1 contained cultured confirmed positive serum samples of brucellosis (n = 15), group 2 contained sera samples from positive cases of brucellosis previously tested by conventional methods of RBPT (n = 28) and STAT (n = 26), group 3 contained sera samples negative by RBPT(n = 36) and STAT (n = 32), group 4 contained sera samples of other febrile illness and PUO case (n = 35) and group 5 contained confirmed negative sera samples from healthy donors (n = 23). The rOmp2a was found to be immunoreactive by iELISA and western blotting. The test showed a sensitivity of 93.75% and specificity of 95.83% when tested against 185 serum samples. For determination of statistical significance between experimental groups and control groups, Student's t test was performed on the data. Omp2a emerges as a potential antigen candidate for serodiagnosis of human brucellosis.
NASA Technical Reports Server (NTRS)
Wingard, Charles Doug; Munafo, Paul M. (Technical Monitor)
2002-01-01
Protein crystals are grown in microgravity experiments inside the Space Shuttle during orbit. Such crystals are basically grown in a five-component system containing a salt, buffer, polymer, organic and water. During these experiments, a number of different polymeric containment materials must be compatible with up to hundreds of different PCG solutions in various concentrations for durations up to 180 days. When such compatibility experiments are performed at NASA/MSFC (Marshall Space Flight Center) simultaneously on containment material samples immersed in various solutions in vials, the samples are rather small out of necessity. DMA4 modulus was often used as the primary screening parameter for such small samples as a pass/fail criterion for incompatibility issues. In particular, the TA Instruments DMA 2980 film tension clamp was used to test rubber O-rings as small in I.D. as 0.091 in. by cutting through the cross-section at one place, then clamping the stretched linear cord stock at each end. The film tension clamp was also used to successfully test short length samples of medical/surgical grade tubing with an O.D. of 0.125 in.
1992-05-15
The laboratory heterogeneity of the lupus anticoagulant (LA) was investigated in a multicentre study using a panel of 78 plasma samples diagnosed as containing a LA. Consecutive samples were collected by 12 participants using various screening tests, and sent to 7 laboratories which performed one or more clotting assays among the following: activated partial thromboplastin time (APTT), dilute Russell viper venom time, kaolin clotting time (KCT), dilute tissue thromboplastin time (dTTI) and a platelet neutralization test. For APTT and dTTI, 10 versions of these tests including standard and mixing procedures were carried out. They varied by reagents, phospholipid concentration or methodology. Cut-off times were determined for each test by comparing the results of the panel to those of a control population. When the data of all clotting assays were pooled, 70 of the 78 selected plasmas were considered to contain LA, 15 of them having a low-titer inhibitor. Sensitivity, defined as the proportion of positive results among LA-containing plasmas, varied from 62 to 100% and was positively related to responsiveness (defined as the mean ratio of clotting time to cut-off time). Laboratory heterogeneity of LA-containing plasma was illustrated by a star symbol plot analysis. Different populations of samples, with LA preferentially recognized by one assay (or group of assays) irrespective of the overall sensitivity of this assay, were identified. Multiple component analysis demonstrated the heterogeneity of low-titer inhibitors, which complicates their recognition in routine laboratory investigation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, D. H.; Reigel, M. M.
A full-scale formed core sampler was designed and functionally tested for use in the Saltstone Disposal Facility (SDF). Savannah River National Laboratory (SRNL) was requested to compare properties of the formed core samples and core drilled samples taken from adjacent areas in the full-scale sampler. While several physical properties were evaluated, the primary property of interest was hydraulic conductivity. Differences in hydraulic conductivity between the samples from the formed core sampler and those representing the bulk material were noted with respect to the initial handling and storage of the samples. Due to testing conditions, the site port samples were exposedmore » to uncontrolled temperature and humidity conditions prior to testing whereas the formed core samples were kept in sealed containers with minimal exposure to an uncontrolled environment prior to testing. Based on the results of the testing, no significant differences in porosity or density were found between the formed core samples and those representing the bulk material in the test stand.« less
Schaffner, Donald W; Jensen, Dane; Gerba, Charles P; Shumaker, David; Arbogast, James W
2018-02-01
Concern has been raised regarding the public health risks from refillable bulk-soap dispensers because they provide an environment for potentially pathogenic bacteria to grow. This study surveyed the microbial quality of open refillable bulk soap in four different food establishment types in three states. Two hundred ninety-six samples of bulk soap were collected from food service establishments in Arizona, New Jersey, and Ohio. Samples were tested for total heterotrophic viable bacteria, Pseudomonas, coliforms and Escherichia coli, and Salmonella. Bacteria were screened for antibiotic resistance. The pH, solids content, and water activity of all soap samples were measured. Samples were assayed for the presence of the common antibacterial agents triclosan and parachlorometaxylenol. More than 85% of the soap samples tested contained no detectable microorganisms, but when a sample contained any detectable microorganisms, it was most likely contaminated at a very high level (∼7 log CFU/mL). Microorganisms detected in contaminated soap included Klebsiella oxytoca, Serratia liquefaciens, Shigella sonnei, Enterobacter gergoviae, Serratia odorifera, and Enterobacter cloacae. Twenty-three samples contained antibiotic-resistant organisms, some of which were resistant to two or more antibiotics. Every sample containing less than 4% solids had some detectable level of bacteria, whereas no samples with greater than 14% solids had detectable bacteria. This finding suggests the use of dilution and/or low-cost formulations as a cause of bacterial growth. There was a statistically significant difference ( P = 0.0035) between the fraction of bacteria-positive samples with no detected antimicrobial agent (17%) and those containing an antimicrobial agent (7%). Fast food operations and grocery stores were more likely to have detectable bacteria in bulk-soap samples compared with convenience stores ( P < 0.05). Our findings underscore the risk to public health from use of refillable bulk-soap dispensers in food service establishments.
Nyman, Patricia J; Wamer, Wayne G; Begley, Timothy H; Diachenko, Gregory W; Perfetti, Gracia A
2010-04-01
Under certain conditions, benzene can form in beverages containing benzoic and ascorbic acids. The American Beverage Assn. (ABA) has published guidelines to help manufacturers mitigate benzene formation in beverages. These guidelines recommend accelerated testing conditions to test product formulations, because exposure to ultraviolet (UV) light and elevated temperature over the shelf life of the beverage may result in benzene formation in products containing benzoic and ascorbic acids. In this study, the effects of UVA exposure on benzene formation were determined. Benzene formation was examined for samples contained in UV stabilized and non-UV stabilized packaging. Additionally, the usefulness of accelerated thermal testing to simulate end of shelf-life benzene formation was evaluated for samples containing either benzoic or ascorbic acid, or both. The 24 h studies showed that under intense UVA light benzene levels increased by as much as 53% in model solutions stored in non-UV stabilized bottles, whereas the use of UV stabilized polyethylene terephthalate bottles reduced benzene formation by about 13% relative to the non-UV stabilized bottles. Similar trends were observed for the 7 d study. Retail beverages and positive and negative controls were used to study the accelerated thermal testing conditions. The amount of benzene found in the positive controls and cranberry juice suggests that testing at 40 degrees C for 14 d may more reliably simulate end of shelf-life benzene formation in beverages. Except for cranberry juice, retail beverages were not found to contain detectable amounts of benzene (<0.05 ng/g) at the end of their shelf lives.
Martins, Daniel; Barratt, Monica J; Pires, Cristiana Vale; Carvalho, Helena; Vilamala, Mireia Ventura; Espinosa, Iván Fornís; Valente, Helena
2017-05-01
This paper describes the misrepresentation of LSD at Portugal's Boom Festival 2014 and the prevention of unintentional consumption of DOx and 25x-NBOMe among LSD consumers attending a drug-checking service. Two hundred forty-five drug samples expected to contain LSD were submitted to the drug-checking service for chemical analysis. One hundred ten post-test questionnaires were successfully matched with test results. About 67.3% of the alleged LSD samples tested contained only LSD; 0.8% contained LSD combined with adulterants; 24.1% did not contain LSD but did contain another psychoactive substance, including 11.4% that were 2,5-dimethoxyamphetamine derivatives and 9.8% that were N-benzyl-2,5-dimethoxyphenethylamine derivatives; and no psychoactive substance was detected in 7.8%. The majority of service users who received unexpected test results regarding their alleged LSD (74.2%) reported that they did not intend to consume the drug. Following dissemination of alerts on day 2, a larger than expected proportion of all tests conducted were for LSD, when comparing the 2014 festival to 2012, where no such alert was disseminated. Although these results support the provision of integrated drug-checking services in party settings, evidence of their utility and effectiveness would be improved through future research incorporating more robust measures of outcomes following provision of drug-checking results. Copyright © 2017 John Wiley & Sons, Ltd.
Community-level assessment of dental plaque bacteria susceptibility to triclosan over 19 years.
Haraszthy, Violet I; Sreenivasan, Prem K; Zambon, Joseph J
2014-06-02
Triclosan is a broad-spectrum antimicrobial agent used in toothpaste to reduce dental plaque, gingivitis and oral malodor. This community-level assessment evaluated the susceptibility of dental plaque bacteria to triclosan in samples collected over 19 years. A total of 155 dental plaque samples were collected at eleven different times over 19 years from 58 adults using 0.3% triclosan, 2% copolymer, 0.243% sodium fluoride toothpaste and from 97 adults using toothpaste without triclosan. These included samples from 21 subjects who used triclosan toothpaste for at least five years and samples from 20 control subjects. The samples were cultured on media containing 0, 7.5 or 25 μg/ml triclosan. Descriptive statistics and p values were computed and a linear regression model and the runs test were used to examine susceptibility over time. Growth inhibition averaged 99.451% (91.209 - 99.830%) on media containing 7.5 μg/ml triclosan and 99.989% (99.670 - 100%) on media containing 25 μg/ml triclosan. There was no change in microbial susceptibility to triclosan over time discernible by regression analysis or the runs test in plaque samples taken over 19 years including samples from subjects using a triclosan-containing dentifrice for at least five years. This community-level assessment of microbial susceptibility to triclosan among supragingival plaque bacteria is consistent with the long-term safety of a 0.3% triclosan, 2% copolymer, 0.243% sodium fluoride dentifrice.
U.S. History: Grades 10-12. Revised Edition.
ERIC Educational Resources Information Center
Instructional Objectives Exchange, Los Angeles, CA.
Seventy-seven behavioral objectives and related test items for United States history in grades 10 through 12 are presented. Each sample contains the objective, sample test items, and criteria for judging the adequacy of student responses. Fourteen of the 15 categories are content-oriented, and presented in chronological groups: (1) discovery of…
40 CFR 61.67 - Emission tests.
Code of Federal Regulations, 2010 CFR
2010-07-01
... being tested is operating at the maximum production rate at which the equipment will be operated and... cross section. The sample is to be extracted at a rate proportional to the gas velocity at the sampling... apply. The average is to be computed on a time weighted basis. (iii) For gas streams containing more...
Graphene-containing PCL- coated Porous 13-93B3 Bioactive Glass Scaffolds for Bone Regeneration
NASA Astrophysics Data System (ADS)
Türk, Mert; Deliormanlı, Aylin M.
2018-04-01
Borate-based 13-93B3 bioactive glass scaffolds were coated with the graphene-containing poly-caprolactone (PCL) solution to prepare electrically conductive composites for biomedical applications. Results revealed that electrical conductivity of the scaffolds increased with increasing concentration of graphene nanoparticles. Significant difference was not observed in hydroxyapatite forming ability of the bare and the graphene-containing scaffolds immersed in simulated body fluid. In vitro cytotoxicity experiments (XTT tests) showed that pre-osteoblastic MC3T3-E1 cell viability percentages of the graphene- containing samples was higher than control group samples after 7 days of incubation. However, a decrease in cell viability rates was obtained after 14 days of incubation for samples coated with PCL containing graphene starting from 3 wt%. Additionally, results obtained in the live-dead assay were consistent with the results of XTT tests. A higher ALP activity was detected in cells cultured on the graphene-containing borate glass scaffolds than those on the bare PCL coated 13-93B3 scaffolds suggesting the presence of graphene nanopowders stimulated an early stage of osteoblastic differentiation. SEM analysis showed that MC3T3-E1 cells exhibited a flat appearance and spread out through the surface in all groups of scaffolds starting from 3 days of incubation.
Shin, Hye Young; Suh, Mina; Baik, Hyung Won; Choi, Kui Son; Park, Boyoung; Jun, Jae Kwan; Hwang, Sang-Hyun; Kim, Byung Chang; Lee, Chan Wha; Oh, Jae Hwan; Lee, You Kyoung; Han, Dong Soo; Lee, Do-Hoon
2016-11-15
We are in the process of conducting a randomized trial to determine whether compliance with the fecal immunochemical test (FIT) for colorectal cancer screening differs according to the stool-collection method. This study was an interim analysis of the performance of two stool-collection devices (sampling bottle vs conventional container). In total, 1,701 individuals (age range, 50 to 74 years) were randomized into the sampling bottle group (intervention arm) or the conventional container group (control arm). In both groups, we evaluated the FIT positivity rate, the positive predictive value for advanced neoplasia, and the detection rate for advanced neoplasia. The FIT positivity rates were 4.1% for the sampling bottles and 2.0% for the conventional containers; these values were significantly different. The positive predictive values for advanced neoplasia in the sampling bottles and conventional containers were 11.1% (95% confidence interval [CI], -3.4 to 25.6) and 12.0% (95% CI, -0.7 to 24.7), respectively. The detection rates for advanced neoplasia in the sampling bottles and conventional containers were 4.5 per 1,000 persons (95% CI, 2.0 to 11.0) and 2.4 per 1,000 persons (95% CI, 0.0 to 5.0), respectively. The impact of these findings on FIT screening performance was unclear in this interim analysis. This impact should therefore be evaluated in the final analysis following the final enrollment period.
Code of Federal Regulations, 2010 CFR
2010-04-01
... fuel alcohol for testing and analysis. Samples of spirits may not be removed from the premises of the alcohol fuel plant. Samples of fuel alcohol may be removed from the premises of the alcohol fuel plant to... that the spirits or fuel alcohol contained therein is a sample. The proprietor shall account for...
Preservation of samples for dissolved mercury
Hamlin, S.N.
1989-01-01
Water samples for dissolved mercury requires special treatment because of the high chemical mobility and volatility of this element. Widespread use of mercury and its compounds has provided many avenues for contamination of water. Two laboratory tests were done to determine the relative permeabilities of glass and plastic sample bottles to mercury vapor. Plastic containers were confirmed to be quite permeable to airborne mercury, glass containers were virtually impermeable. Methods of preservation include the use of various combinations of acids, oxidants, and complexing agents. The combination of nitric acid and potassium dichromate successfully preserved mercury in a large variety of concentrations and dissolved forms. Because this acid-oxidant preservative acts as a sink for airborne mercury and plastic containers are permeable to mercury vapor, glass bottles are preferred for sample collection. To maintain a healthy work environment and minimize the potential for contamination of water samples, mercury and its compounds are isolated from the atmosphere while in storage. Concurrently, a program to monitor environmental levels of mercury vapor in areas of potential contamination is needed to define the extent of mercury contamination and to assess the effectiveness of mercury clean-up procedures.Water samples for dissolved mercury require special treatment because of the high chemical mobility and volatility of this element. Widespread use of mercury and its compounds has provided many avenues for contamination of water. Two laboratory tests were done to determine the relative permeabilities of glass and plastic sample bottles to mercury vapor. Plastic containers were confirmed to be quite permeable to airborne mercury, glass containers were virtually impermeable. Methods of preservation include the use of various combinations of acids, oxidants, and complexing agents. The combination of nitric acid and potassium dichromate successfully preserved mercury in a large variety of concentrations and dissolved forms.
Dunn, Kevin H.; Tsai, Candace Su-Jung; Woskie, Susan R.; Bennett, James S.; Garcia, Alberto; Ellenbecker, Michael J.
2015-01-01
The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 feet/minute) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust air flows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in background concentrations to allow for increased sensitivity. PMID:25175285
Dunn, Kevin H; Tsai, Candace Su-Jung; Woskie, Susan R; Bennett, James S; Garcia, Alberto; Ellenbecker, Michael J
2014-01-01
The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 ft/min) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust airflows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in background concentrations to allow for increased sensitivity.
USDA-ARS?s Scientific Manuscript database
We report the laboratory analysis of 125 clinical samples from suspected cases of foot-and-mouth disease (FMD) in cattle and Asian buffalo collected in Pakistan between 2008 and 2012. Of these samples, 89 were found to contain viral RNA by rRT-PCR, of which 88 were also found to contain infectious F...
Criterion-Referenced Test Items for Welding.
ERIC Educational Resources Information Center
Davis, Diane, Ed.
This test item bank on welding contains test questions based upon competencies found in the Missouri Welding Competency Profile. Some test items are keyed for multiple competencies. These criterion-referenced test items are designed to work with the Vocational Instructional Management System. Questions have been statistically sampled and validated…
IMPROVED METHOD FOR THE STORAGE OF GROUND WATER SAMPLES CONTAINING VOLATILE ORGANIC ANALYTES
The sorption of volatile organic analytes from water samples by the Teflon septum surface used with standard glass 40-ml sample collection vials was investigated. Analytes tested included alkanes, isoalkanes, olefins, cycloalkanes, a cycloalkene, monoaromatics, a polynuclear arom...
It's Time to Develop a New "Draft Test Protocol" for a Mars Sample Return Mission (or Two…).
Rummel, John D; Kminek, Gerhard
2018-04-01
The last time NASA envisioned a sample return mission from Mars, the development of a protocol to support the analysis of the samples in a containment facility resulted in a "Draft Test Protocol" that outlined required preparations "for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth" (Rummel et al., 2002 ). This document comprised a specific protocol to be used to conduct a biohazard test for a returned martian sample, following the recommendations of the Space Studies Board of the US National Academy of Sciences. Given the planned launch of a sample-collecting and sample-caching rover (Mars 2020) in 2 years' time, and with a sample return planned for the end of the next decade, it is time to revisit the Draft Test Protocol to develop a sample analysis and biohazard test plan to meet the needs of these future missions. Key Words: Biohazard detection-Mars sample analysis-Sample receiving facility-Protocol-New analytical techniques-Robotic sample handling. Astrobiology 18, 377-380.
Serologic Evidence of Lyssavirus Infection in Bats, Cambodia
Molia, Sophie; Audry, Laurent; Hout, Sotheara; Ngin, Sopheak; Walston, Joe; Bourhy, Hervé
2004-01-01
In Cambodia, 1,303 bats of 16 species were tested for lyssavirus. No lyssavirus nucleocapsid was detected in 1,283 brains tested by immunofluorescence assay. Antibodies against lyssaviruses were detected by enzyme-linked immunosorbent assay in 144 (14.7%) of 981 serum samples. Thirty of 187 serum samples contained neutralizing antibodies against different lyssaviruses. PMID:15663870
Examples of Data Analysis with SPSS/PC+ Studentware.
ERIC Educational Resources Information Center
MacFarland, Thomas W.
Intended for classroom use only, these unpublished notes contain computer lessons on descriptive statistics with files previously created in WordPerfect 4.2 and Lotus 1-2-3 Version 1.A for the IBM PC+. The statistical measures covered include Student's t-test with two independent samples; Student's t-test with a paired sample; Chi-square analysis;…
Robotic Sample Manipulator for Handling Astromaterials Inside the Geolab Microgravity Glovebox
NASA Technical Reports Server (NTRS)
Bell, Mary S.; Calaway, M. J.; Evans, C. A.; Li,Z.; Tong, S.; Zhong, Y.; Dahiwala, R.; Wang, L.; Porter, F.
2013-01-01
Future human and robotic sample return missions will require isolation containment systems with strict protocols and procedures for reducing inorganic and organic contamination. Robotic handling and manipulation of astromaterials may be required for preliminary examination inside such an isolation containment system. In addition, examination of astromaterials in microgravity will require constant contact to secure samples during manipulation. The National Space Grant Foundation exploration habitat (XHab) academic innovative challenge 2012 administered through the NASA advanced exploration systems (AES) deep space habitat (DSH) project awarded funding to the University of Bridgeport team to develop an engineering design for tools to facilitate holding and handling geological samples for analysis in a microgravity glovebox environment. The Bridgeport XHab team developed a robotic arm system with a three-finger gripper that could manipulate geologic samples within the existing GeoLab glovebox integrated into NASA's DSH called the GeoLab Robotic Sample Manipulator (see fig. 1 and 2). This hardware was deployed and tested during the 2012 DSH mission operations tests [1].
Douglas, Timothy E L; Piwowarczyk, Wojciech; Pamula, Elzbieta; Liskova, Jana; Schaubroeck, David; Leeuwenburgh, Sander C G; Brackman, Gilles; Balcaen, Lieve; Detsch, Rainer; Declercq, Heidi; Cholewa-Kowalska, Katarzyna; Dokupil, Agnieszka; Cuijpers, Vincent M J I; Vanhaecke, Frank; Cornelissen, Ria; Coenye, Tom; Boccaccini, Aldo R; Dubruel, Peter
2014-08-01
Hydrogels of biocompatible calcium-crosslinkable polysaccharide gellan gum (GG) were enriched with bioglass particles to enhance (i) mineralization with calcium phosphate (CaP); (ii) antibacterial properties and (iii) growth of bone-forming cells for future bone regeneration applications. Three bioglasses were compared, namely one calcium-rich and one calcium-poor preparation both produced by a sol-gel technique (hereafter referred to as A2 and S2, respectively) and one preparation of composition close to that of the commonly used 45S5 type (hereafter referred to as NBG). Incubation in SBF for 7 d, 14 d and 21 d caused apatite formation in bioglass-containing but not in bioglass-free samples, as confirmed by FTIR, XRD, SEM, ICP-OES, and measurements of dry mass, i.e. mass attributable to polymer and mineral and not water. Mechanical testing revealed an increase in compressive modulus in samples containing S2 and NBG but not A2. Antibacterial testing using biofilm-forming meticillin-resistant staphylococcus aureus (MRSA) showed markedly higher antibacterial activity of samples containing A2 and S2 than samples containing NBG and bioglass-free samples. Cell biological characterization using rat mesenchymal stem cells (rMSCs) revealed a stimulatory effect of NBG on rMSC differentiation. The addition of bioglass thus promotes GG mineralizability and, depending on bioglass type, antibacterial properties and rMSC differentiation.
NASA Technical Reports Server (NTRS)
VonMeerwall, Ernst D.
1994-01-01
The project involved the impact testing of a kevlar-like woven polymer material, PBO. The purpose was to determine whether this material showed any promise as a lightweight replacement material for jet engine fan containment. The currently used metal fan containment designs carry a high drag penalty due to their weight. Projectiles were fired at samples of PBO by means of a 0.5 inch diameter Helium powered gun. The Initial plan was to encase the samples inside a purpose-built steel "hot box" for heating and ricochet containment. The research associate's responsibility was to develop the data acquisition programs and techniques necessary to determine accurately the impacting projectile's velocity. Beyond this, the Research Associate's duties include any physical computations, experimental design, and data analysis necessary.
7 CFR 58.812 - Methods of sample analysis.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Methods of sample analysis. 58.812 Section 58.812... Procedures § 58.812 Methods of sample analysis. Samples shall be tested according to the applicable methods of laboratory analysis contained in either DA Instruction 918-RL, as issued by the USDA, Agricultural...
7 CFR 58.245 - Method of sample analysis.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Method of sample analysis. 58.245 Section 58.245... Procedures § 58.245 Method of sample analysis. Samples shall be tested according to the applicable methods of laboratory analysis contained in either DA Instruction 918-RL as issued by the USDA, Agricultural Marketing...
Burmeister, T; Maurer, J; Aivado, M; Elmaagacli, A H; Grünebach, F; Held, K R; Hess, G; Hochhaus, A; Höppner, W; Lentes, K U; Lübbert, M; Schäfer, K L; Schafhausen, P; Schmidt, C A; Schüler, F; Seeger, K; Seelig, R; Thiede, C; Viehmann, S; Weber, C; Wilhelm, S; Christmann, A; Clement, J H; Ebener, U; Enczmann, J; Leo, R; Schleuning, M; Schoch, R; Thiel, E
2000-10-01
Here we describe the results of an interlaboratory test for RT-PCR-based BCR/ABL analysis. The test was organized in two parts. The number of participating laboratories in the first and second part was 27 and 20, respectively. In the first part samples containing various concentrations of plasmids with the ela2, b2a2 or b3a2 BCR/ABL transcripts were analyzed by PCR. In the second part of the test, cell samples containing various concentrations of BCR/ABL-positive cells were analyzed by RT-PCR. Overall PCR sensitivity was sufficient in approximately 90% of the tests, but a significant number of false positive results were obtained. There were significant differences in sensitivity in the cell-based analysis between the various participants. The results are discussed, and proposals are made regarding the choice of primers, controls, conditions for RNA extraction and reverse transcription.
Blake, Charles L; Dotson, G Scott; Harbison, Raymond D
2006-07-01
Five test sessions were conducted to assess asbestos exposure during the removal or installation of asbestos-containing gaskets on vehicles. All testing took place within an operative automotive repair facility involving passenger cars and a pickup truck ranging in vintage from late 1960s through 1970s. A professional mechanic performed all shop work including engine disassembly and reassembly, gasket manipulation and parts cleaning. Bulk sample analysis of removed gaskets through polarized light microscopy (PLM) revealed asbestos fiber concentrations ranging between 0 and 75%. Personal and area air samples were collected and analyzed using National Institute of Occupational Safety Health (NIOSH) methods 7400 [phase contrast microscopy (PCM)] and 7402 [transmission electron microscopy (TEM)]. Among all air samples collected, approximately 21% (n = 11) contained chrysotile fibers. The mean PCM and phase contrast microscopy equivalent (PCME) 8-h time weighted average (TWA) concentrations for these samples were 0.0031 fibers/cubic centimeters (f/cc) and 0.0017 f/cc, respectively. Based on these findings, automobile mechanics who worked with asbestos-containing gaskets may have been exposed to concentrations of airborne asbestos concentrations approximately 100 times lower than the current Occupational Safety and Health Administration (OSHA) Permissible Exposure Limit (PEL) of 0.1 f/cc.
Community-level assessment of dental plaque bacteria susceptibility to triclosan over 19 years
2014-01-01
Background Triclosan is a broad-spectrum antimicrobial agent used in toothpaste to reduce dental plaque, gingivitis and oral malodor. This community-level assessment evaluated the susceptibility of dental plaque bacteria to triclosan in samples collected over 19 years. Methods A total of 155 dental plaque samples were collected at eleven different times over 19 years from 58 adults using 0.3% triclosan, 2% copolymer, 0.243% sodium fluoride toothpaste and from 97 adults using toothpaste without triclosan. These included samples from 21 subjects who used triclosan toothpaste for at least five years and samples from 20 control subjects. The samples were cultured on media containing 0, 7.5 or 25 μg/ml triclosan. Descriptive statistics and p values were computed and a linear regression model and the runs test were used to examine susceptibility over time. Results Growth inhibition averaged 99.451% (91.209 - 99.830%) on media containing 7.5 μg/ml triclosan and 99.989% (99.670 - 100%) on media containing 25 μg/ml triclosan. There was no change in microbial susceptibility to triclosan over time discernible by regression analysis or the runs test in plaque samples taken over 19 years including samples from subjects using a triclosan-containing dentifrice for at least five years. Conclusions This community-level assessment of microbial susceptibility to triclosan among supragingival plaque bacteria is consistent with the long-term safety of a 0.3% triclosan, 2% copolymer, 0.243% sodium fluoride dentifrice. PMID:24889743
21 CFR 640.92 - Tests on final product.
Code of Federal Regulations, 2010 CFR
2010-04-01
... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.92 Tests on...) Heat stability. A final container sample of Plasma Protein Fraction (Human) shall remain unchanged, as...
21 CFR 640.92 - Tests on final product.
Code of Federal Regulations, 2012 CFR
2012-04-01
... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.92 Tests on...) Heat stability. A final container sample of Plasma Protein Fraction (Human) shall remain unchanged, as...
21 CFR 640.92 - Tests on final product.
Code of Federal Regulations, 2011 CFR
2011-04-01
... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.92 Tests on...) Heat stability. A final container sample of Plasma Protein Fraction (Human) shall remain unchanged, as...
21 CFR 640.92 - Tests on final product.
Code of Federal Regulations, 2013 CFR
2013-04-01
... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.92 Tests on...) Heat stability. A final container sample of Plasma Protein Fraction (Human) shall remain unchanged, as...
21 CFR 640.92 - Tests on final product.
Code of Federal Regulations, 2014 CFR
2014-04-01
... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.92 Tests on...) Heat stability. A final container sample of Plasma Protein Fraction (Human) shall remain unchanged, as...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramey, M.R.; Daie-e, G.
1988-07-01
There are certain hazardous wastes that must be contained in an extremely secure vessel for transportation and disposal. The vessel, among other things, must be able to withstand relatively large impacts without rupturing. Such containment vessels therefore must be able to absorb substantial amounts of energy during an impact and still perform their function. One of the impacts that the vessel must withstand is a 30-foot fall onto an unyielding surface. For some disposal scenarios it is proposed to encase the waste in a steel enclosure which is to be surrounded by a thick layer of concrete which, in turn,more » is encased by a relatively thin steel shell. Tests on concrete in compression and flexure, including static, dynamic and impact tests, have shown that low modulus concretes tend to behave in a less brittle manner than higher modulus concretes. Tests also show that fiber reinforced concretes have significantly greater ductility, crack propagation resistance and toughness than conventional concretes. Since it is known that concrete is a reasonably brittle material, it is necessary to do impact tests on sample containment structures consisting of thin-walled metal containers having closed ends which are filled with concrete, grout, or fiber reinforced concrete. This report presents the results of simple tests aimed at observing the behavior of sample containment structures subjected to impacts due to a fall from 30 feet. 8 figs., 4 tabs.« less
Microbiological Survey of Packaged Ready-to-Eat Red Meats at Retail in New Zealand.
Rivas, Lucia; Horn, Beverley; Cook, Roger; Castle, Marion
2017-10-04
A microbiological survey was undertaken on packaged ready-to-eat red meats available at retail in New Zealand. A total of 1,485 samples (297 lots of five samples each) were collected according to a sampling plan based on market share and regulatory regimes (Animal Products Act 1999 and Food Act 1981) and were tested against the microbiological limits specified in Food Standards Code (FSC) 1.6.1 applicable at the time of sampling. Each lot was tested as a composite for the presence or absence of Salmonella spp., coagulase-producing staphylococci, Listeria monocytogenes, and other Listeria spp. at the end of the manufacturer's stated shelf life. Individual samples within a positive lot were subsequently enumerated for L. monocytogenes. None of the samples contained Salmonella spp. or had coagulase-producing staphylococci counts above the acceptable level specified in FSC 1.6.1 (>100 CFU/g). Data showed that 93.6% (278 of 297 lots) of ready-to-eat red meat complied with the FSC 1.6.1 criteria applicable at the time of the survey. The failure of 19 lots (6.4%) was due to the presence of L. monocytogenes from product obtained from 8 of 33 producers tested. Thirteen samples of 95 positive samples were found to contain between 50 and 500 CFU/g L. monocytogenes, but all of these samples were manufactured by the same operator. Pulsed-field gel electrophoresis typing of all of the L. monocytogenes isolates obtained from the survey identified 12 different pulsotypes. Different pulsotypes were often identified in samples from the same operator sampled on separate occasions. A total of 46 lots (15.5%) contained Listeria spp. (including L. monocytogenes). The detection of Listeria in samples may highlight the existence of problems in operator processing and/or packaging processes and suggests that improvements in good hygienic practice and implementation of more effective risk mitigation strategies are needed.
The Mars Sample Return Lab(s) - Lessons from the Past and Implications for the Future
NASA Technical Reports Server (NTRS)
Allen, Carlton
2012-01-01
It has been widely understood for many years that an essential component of a Mars Sample Return mission is a Sample Receiving Facility (SRF). The purpose of such a facility would be to take delivery of the flight hardware that lands on Earth, open the spacecraft and extract the sample container and samples, and conduct an agreed upon test protocol, while ensuring strict containment and contamination control of the samples while in the SRF. Any samples that are found to be non-hazardous (or are rendered non-hazardous by sterilization) would then be transferred to long-term curation. Although the general concept of an SRF is relatively straightforward, there has been considerable discussion about implementation planning.
Potential toxic effects of aircraft de-icers and wastewater samples containing these compounds.
Mohiley, A; Franzaring, J; Calvo, O C; Fangmeier, A
2015-09-01
One of the major problems of airport operation is the impact of pollution caused by runoff waters. Runoff waters at an airport may contain high concentrations of different contaminants resulting from various activities of its operation. High quantities of aircraft de-icing/anti-icing fluids are used annually at airports worldwide. Aircraft de-icers and anti-icers may have negative environmental impacts, but their effects on aquatic organisms are virtually unknown. In order to address this issue, aircraft de-icers, pavement de-icers and wastewater samples were obtained from a regional airport. To evaluate the toxicity of wastewater samples and aircraft de-icing/anti-icing fluids (ADAFs), two bio-tests were performed: the Lemna growth inhibition test according to OECD guideline 221 and the luminescent bacteria test according to ISO guideline 11348-2. In the Lemna growth inhibition test, phytotoxicity was assessed using the endpoints frond number and frond area. The luminescent bacteria test involved the marine bacterium Vibrio fischeri. The estimates of effective concentrations (EC50) values were determined using the free software R and the "drc" library. Aquatic plants and marine bacteria showed a higher sensitivity towards ADAFs than to wastewater samples. Experiments showed that aircraft de-icing/anti-icing fluids and wastewater samples were relatively more toxic towards Lemna gibba L. in comparison to V. fischeri.
Bakken, L L; Callister, S M; Wand, P J; Schell, R F
1997-01-01
In 1991, we reported that 55% of laboratories participating in the Wisconsin Proficiency Testing Program could not accurately identify serum samples from Lyme disease patients containing antibody against Borrelia burgdorferi. The purpose of this study was to determine whether the accuracy of Lyme disease test results reported by approximately 500 participants in the Wisconsin State Laboratory of Hygiene/College of American Pathologists Lyme Disease Survey had improved. From 1992 through 1994, 50 serum samples were sent to participants of the survey. Each laboratory received 28 serum samples from individuals with Lyme disease according to the case definition of the Centers for Disease Control and Prevention and 22 serum samples from healthy individuals. Unfortunately, the serodiagnosis of Lyme disease by participants had not improved. The specificity of the Lyme disease assays steadily decreased from approximately 95% to approximately 81% during the 3-year period of the survey. False-positive test results approached 55% with some of the serum samples from healthy donors. A serum sample containing antibody against Treponema pallidum was reported as positive by 70% of the participants. In addition, the sensitivity fluctuated between 93 and 75%, depending upon the conjugate used by the laboratories. These results suggest that stronger criteria must be applied for approving and continuing to approve commercially available kits for the serodiagnosis of Lyme disease. PMID:9041384
Spelling for the Office. Competency Test Package. Office Occupations. Instructor's Guide.
ERIC Educational Resources Information Center
Hines, Donna
This competency test package, one of a series of test packages for office occupations education, contains a list of performance objectives; a pool of objective questions matched with these performance objectives; a sample, 50-point objective test; and several performance test activities. The package also includes complete directions for the…
Basic Skills for Word Processing. Competency Test Package. Office Occupations. Instructor's Guide.
ERIC Educational Resources Information Center
Hines, Donna
This competency test package, one of a series of test packages for office occupations education, contains a list of performance objectives; a pool of objective questions matched with these performance objectives; a sample, 50-point objective test; and several performance test activities. The package also includes complete directions for the…
Business Telephone Etiquette. Comptetency Test Package. Office Occupations. Instructor's Guide.
ERIC Educational Resources Information Center
Hines, Donna
This competency test package, one of a series of test packages for office occupations education, contains a list of performance objectives: a sample, 50-point objective test; and several performance test activities. The package also includes complete directions for the student and the instructor, plus answer keys and a guide for evaluating the…
Quality Testing of Artemisinin-Based Antimalarial Drugs in Myanmar.
Guo, Suqin; Kyaw, Myat Phone; He, Lishan; Min, Myo; Ning, Xiangxue; Zhang, Wei; Wang, Baomin; Cui, Liwang
2017-10-01
Artemisinin-based combination therapies are the frontline treatment of Plasmodium falciparum malaria. The circulation of falsified and substandard artemisinin-based antimalarials in Southeast Asia has been a major predicament for the malaria elimination campaign. To provide an update of this situation, we purchased 153 artemisinin-containing antimalarials, as convenience samples, in private drug stores from different regions of Myanmar. The quality of these drugs in terms of their artemisinin derivative content was tested using specific dipsticks for these artemisinin derivatives, as point-of-care devices. A subset of these samples was further tested by high-performance liquid chromatography (HPLC). This survey identified that > 35% of the collected drugs were oral artesunate and artemether monotherapies. When tested with the dipsticks, all but one sample passed the assays, indicating that the detected artemisinin derivative content corresponded approximately to the labeled contents. However, one artesunate injection sample was found to contain no active ingredient at all by the dipstick assay and subsequent HPLC analysis. The continued circulation of oral monotherapies and the description, for the first time, of falsified parenteral artesunate provides a worrisome picture of the antimalarial drug quality in Myanmar during the malaria elimination phase, a situation that deserves more oversight from regulatory authorities.
Shen, Qing; Jiang, Tao; Li, Nan; Wang, Jiahui; Han, Chunhui; Zhang, Jing; Xu, Jin; Zhang, Dongfeng; Li, Fengqin
2014-11-01
The roasted fish fillet sample at the retail collected in Beijing and Qingdao were detected for TTX, and the TTX positive samples was analyzed for fish species identification. TTX was tested by EUSA method and the cytochrome c oxidase I (COI) genome of TTX-positive samples was extracted and identified by DNA barcode. Totally, 90 samples were tested by EUSA and 58 (64.4%) samples were positive for TTX with the levels ranging from 0.10 mg/kg to 63.81 mg/kg. Among the TTX positive samples, 24 (41.3%) were identified containing toxic puffer fish and 21 (87.5%) were Lagocephalus lunaris, the highly toxic puffer fish. Some roasted fish fillet samples obtained from the retail in two cities were positive for TTX and contained toxic puffer fish. Based on these results, we suggest that roasted fish fillet producers should prevent toxic puffer fish from mixing in the raw material and the I regulators should strengthen the TTX surveillance and product labeling supervision of roasted fish fillet.
Lotspeich, Erica; Kitts, Kelley; Goodpaster, John
2012-07-10
It is a common misconception that the amount of explosive is the chief contributor to the quantity of vapor that is available to trained canines. In fact, this quantity (known as odor availability) depends not only on the amount of explosive material, but also the container volume, explosive vapor pressure and temperature. In order to better understand odor availability, headspace experiments were conducted and the results were compared to theory. The vapor-phase concentrations of three liquid explosives (nitromethane, nitroethane and nitropropane) were predicted using the Ideal Gas Law for containers of various volumes that are in use for canine testing. These predictions were verified through experiments that varied the amount of sample, the container size, and the temperature. These results demonstrated that the amount of sample that is needed to saturate different sized containers is small, predictable and agrees well with theory. In general, and as expected, once the headspace of a container is saturated, any subsequent increase in sample volume will not result in the release of more vapors. The ability of canines to recognize and alert to differing amounts of nitromethane has also been studied. In particular, it was found that the response of trained canines is independent of the amount of nitromethane present, provided it is a sufficient quantity to saturate the container in which it is held. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Crill, Catherine M; Hak, Emily B; Robinson, Lawrence A; Helms, Richard A
2010-06-01
Microbial contamination associated with different methods of neonatal intravenous fat emulsion (IVFE) preparation and delivery was evaluated. Sterility testing was performed on IVFE dispensed via three different methods: (1) in the original container (n = 60), (2) repackaged into a syringe (n = 90), and (3) drawdown of the original container (n = 60). At the end of each infusion (24 hours for methods 1 and 3, 12 hours for method 2), a sample of the IVFE was withdrawn from the container using a sterile syringe in an International Organization for Standardization class 5 hood and sent to the hospital microbiology laboratory, where the samples were introduced into blood culture bottles and incubated for five days. Each sample was then subcultured on a blood agar plate with olive oil and left for an additional two days in a carbon dioxide incubator to assess for Malassezia furfur. None of the samples from the original containers showed bacterial or fungal growth. Three of the samples from syringes had bacterial growth (two samples contained coagulase-negative staphylococcus and one contained both Klebsiella oxytoca and Citrobacter freundii), yielding a contamination rate of 3.3%. The number of contaminated samples did not significantly differ among the three preparation methods (p = 0.13). Repackaging IVFE into sterile syringes resulted in bacterial contamination and should be avoided in clinical practice. IVFE samples obtained using the drawdown procedure under sterile conditions for infusion over 24 hours revealed no microbial contamination.
Analytical test results for archived core composite samples from tanks 241-TY-101 and 241-TY-103
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beck, M.A.
1993-07-16
This report describes the analytical tests performed on archived core composite samples form a 1.085 sampling of the 241-TY-101 (101-TY) and 241-TY-103 (103-TY) single shell waste tanks. Both tanks are suspected of containing quantities of ferrocyanide compounds, as a result of process activities in the late 1950`s. Although limited quantities of the composite samples remained, attempts were made to obtain as much analytical information as possible, especially regarding the chemical and thermal properties of the material.
1989-08-31
residual product; 3] the processing characteristics of the soil and sludge, and 4] the response of the adjacent scil to the treatment. Attainment of...waste after the completion of the test. EF Sample Composite Procedure The fcllov.wng p-ccedure shculd be followed when sample compositing of scils is...mring’ cowi. The scil shCuld be removed from its original sample container Thrcugh the use cf a dioposable wooden tongue depressor. Each sample should
Mutagenicity in emissions from coal- and oil-fired boilers.
Alfheim, I; Bergström, J G; Jenssen, D; Møller, M
1983-01-01
The mutagenicity of emission samples from three oil-fired and four coal-fired boilers have been compared by using the Salmonella/microsome assay. Very little or no mutagenic activity was observed in samples from five of these boilers. The sample from one oil-fired boiler showed mutagenic activity of about 500 revertants/MJ, and the sample from a coal-fired fluidized bed combustor had an activity of 58,000 revertants/MJ measured with strain TA 98 in the absence of metabolic activation. All samples contained substances that were cytotoxic to the test bacteria, thus making it difficult to obtain linear dose-response curves. Mutagenic activity at low levels may remain undetected due to this toxicity of the samples. Samples with mutagenic activity below the detection limit in the Salmonella test have also been tested for forward mutations at the HGPRT locus in V79 hamster cells. Weak mutagenic effects were detected in two of the samples, whereas the sample from one oil-fired boiler remained negative. In this test, as well as in the Salmonella test, a strong cytotoxic effect could be observed with all samples. PMID:6825617
Schallig, Henk D F H; da Silva, Eduardo S; van der Meide, Wendy F; Schoone, Gerard J; Gontijo, Celia M F
2007-01-01
Identification of the zoonotic reservoir is important for leishmaniasis control program. A number of (wild) animal species may serve as reservoir hosts, including the opossum Didelphis marsupialis. A survey carried out in Didelphis specimens (n = 111) from the metropolitan region of Belo Horizonte, an important focus of human leishmaniasis in Brazil, is reported. All animals were serologically tested with indirect fluorescence antibody test (IFAT) and direct agglutination tests (DAT) based on L. (L.) donovani or L. (V.) braziliensis antigen. A sub-population (n = 20) was analyzed with polymerase chain reaction (PCR) for the presence of Leishmania-specific DNA. For species identification, PCR-positive samples were subjected to restriction enzyme fragment polymorphism (RFLP) analysis. Depending on the sero-diagnostic test employed, the sero-prevalence varied between 8.1% (9/111 animals positive with DAT test based on L. braziliensis antigen) and 21.6% (24/111 animals positive with IFAT). Five out of 20 samples analyzed with PCR tested positive for the presence of Leishmania-specific DNA. RFLP analysis revealed that two samples contained L. braziliensis complex DNA, one contained L. donovani complex DNA, and two samples could not be typed with the methodology used. These data suggest a potential role for the opossum as a reservoir host for zoonotic leishmaniasis in the region.
Etiology of Early Lifestage Diseases, Project 84-44, 1985 Final Report.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sauter, R.W.
1986-10-01
Each year hatcheries experience loss of eggs, fry and fingerlings due to a group of poorly defined diseases called White Spot and Coagulated Yolk. Samples of maternal blood and ovarian fluid (coelomic fluid), as well as unfertilized eggs, were collected at spawning and subsequently tested for the presence of bacteria. Our tests reveal that there is a wide range in mortality rates experienced by the progeny of different brood salmon. Microbiologic tests revealed that these eggs contained a variety of both Gram positive and Gram negative bacteria within their yolk and that the fluids from the females who produced thesemore » lots were contaminated with a variety of bacteria. In contrast the eggs and maternal fluids from the six egg lots which experienced the lowest mortalities did not contain high numbers of Gram positive bacteria and contributed only 5% of the total mortalities observed within the 30 egg lots tested. From the 60 egg lots tested over two brood years we have isolated 18 different bacterial genera containing 32 different species from within the yolk surface sterilized, unfertilized eggs. Our tests suggest that Aeromonas hydrophila, Pseudomonas (3 species) Staphylococcus aureus, Vibrio sp., Corynebacterium hoffmanii, Listeria sp. and Bacillus sp. when detected within the yolk of eggs sampled from egg lots prior to fertilization will be associated with higher than normal mortality rates when the remainder of the egg lots containing these bacteria are incubated and reared. 36 refs., 16 figs.« less
Property Relationship in Organosilanes and Nanotubes Filled Polypropylene Hybrid Composites
Monsiváis-Barrón, Alejandra J.; Bonilla-Rios, Jaime; Sánchez-Fernández, Antonio
2014-01-01
Polypropylene composites with different filler contents were prepared by creating a masterbatch containing 3 wt%. filler. A variety of silanol groups were used to synthetized three compounds in different media trough a sol-gel process with acetic acid, formic acid and ammonium hydroxide as catalysts. Besides, four different nanotubular fillers were also used to analyze their behavior and compare it with the effect caused by the silanol groups. These tubular structures comprise: unmodified halloysite, carbon nanotubes and functionalized halloysite and carbon nanotubes. Morphological characterization in SEM and STEM/TEM showed dispersion in the polypropylene matrix. According to TGA and DSC measurements thermal behavior remain similar for all the composites. Mechanical test in tension demonstrate that modulus of the composites increases for all samples with a major impact for materials containing silanol groups synthetized in formic acid. Rheological measurements show a significantly increment in viscosity for samples containing unmodified and modified carbon nanotubes. No difference was found for samples containing silanol groups and halloysite when compared to neat polypropylene. Finally, the oxygen transmission rate increased for all samples showing high barrier properties only for samples containing natural and functionalized halloysite nanotubes. PMID:28788233
Property Relationship in Organosilanes and Nanotubes Filled Polypropylene Hybrid Composites.
Monsiváis-Barrón, Alejandra J; Bonilla-Rios, Jaime; Sánchez-Fernández, Antonio
2014-10-20
Polypropylene composites with different filler contents were prepared by creating a masterbatch containing 3 wt%. filler. A variety of silanol groups were used to synthetized three compounds in different media trough a sol-gel process with acetic acid, formic acid and ammonium hydroxide as catalysts. Besides, four different nanotubular fillers were also used to analyze their behavior and compare it with the effect caused by the silanol groups. These tubular structures comprise: unmodified halloysite, carbon nanotubes and functionalized halloysite and carbon nanotubes. Morphological characterization in SEM and STEM/TEM showed dispersion in the polypropylene matrix. According to TGA and DSC measurements thermal behavior remain similar for all the composites. Mechanical test in tension demonstrate that modulus of the composites increases for all samples with a major impact for materials containing silanol groups synthetized in formic acid. Rheological measurements show a significantly increment in viscosity for samples containing unmodified and modified carbon nanotubes. No difference was found for samples containing silanol groups and halloysite when compared to neat polypropylene. Finally, the oxygen transmission rate increased for all samples showing high barrier properties only for samples containing natural and functionalized halloysite nanotubes.
Salter, Robert; Holmes, Steven; Legg, David; Coble, Joel; George, Bruce
2012-02-01
Pork tissue samples that tested positive and negative by the Charm II tetracycline test screening method in the slaughter plant laboratory were tested with the modified AOAC International liquid chromatography tandem mass spectrometry (LC-MS-MS) method 995.09 to determine the predictive value of the screening method at detecting total tetracyclines at 10 μg/kg of tissue, in compliance with Russian import regulations. There were 218 presumptive-positive tetracycline samples of 4,195 randomly tested hogs. Of these screening test positive samples, 83% (182) were positive, >10 μg/kg by LC-MS-MS; 12.8% (28) were false violative, greater than limit of detection (LOD) but <10 μg/kg; and 4.2% (8) were not detected at the LC-MS-MS LOD. The 36 false-violative and not-detected samples represent 1% of the total samples screened. Twenty-seven of 30 randomly selected tetracycline screening negative samples tested below the LC-MS-MS LOD, and 3 samples tested <3 μg/kg chlortetracycline. Results indicate that the Charm II tetracycline test is effective at predicting hogs containing >10 μg/kg total tetracyclines in compliance with Russian import regulations.
Distribution of gold, tellurium, silver, and mercury in part of the Cripple Creek district, Colorado
Gott, Garland Bayard; McCarthy, J.H.; Van Sickle, G.H.; McHugh, J.B.
1967-01-01
Geochemical exploration studies were undertaken in the Cripple Creek district to test the possibility that large low-grade gold deposits might be found. Surface rock samples taken throughout the district indicate that the volcanic rocks between the productive veins contain an average of about 0.6 ppm (part per million) gold. In an area above 3,800 feet long and 500 feet wide near the Cresson mine in the south-central part of the district, scattered surface samples show that the rocks contain an average of 2.5 ppm gold, equivalent to $2.50 per ton. Inasmuch as veins that contain more than 2.5 ppm may also exist in the area, systematic sampling by trenching and drilling is warranted.
Effects of tritium gas exposure on the dynamic mechanical properties of EPDM elastomer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark, E. A.; Staack, G. C.
2008-07-15
Samples of ethylene propylene diene monomer (EPDM) elastomer were exposed to tritium gas in closed containers at 101 kPa (1 atmosphere) pressure and ambient temperature for about one week. Tritium exposure effects on the samples were characterized by dynamic mechanical analysis (DMA) and radiolysis products were characterized by measuring the total final pressure and composition in the exposure containers at the end of exposure period. There was no effect of one week tritium exposure on the glass transition temperature, Tg, of the samples tested. Impurity gases produced in the closed containers included HT and lesser amounts of H{sub 2}, DTO,more » and CT{sub 4}. The total pressure remained the same during exposure. (authors)« less
EFFECTS OF TRITIUM GAS EXPOSURE ON THE DYNAMIC MECHANICAL PROPERTIES OF EPDM ELASTOMER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark, E; Gregory Staack, G
2007-08-13
Samples of ethylene propylene diene monomer (EPDM) elastomer were exposed to tritium gas in closed containers initially at 101 kPa (1 atmosphere) pressure and ambient temperature for about one week. Tritium exposure effects on the samples were characterized by dynamic mechanical analysis (DMA) and radiolysis products were characterized by measuring the total final pressure and composition in the exposure containers at the end of exposure period. There was no effect of one week tritium exposure on the glass transition temperature, Tg, of the samples tested. Impurity gases produced in the closed containers included HT and lesser amounts of H{sub 2},more » DTO, and CT{sub 4}. The total pressure remained the same during exposure.« less
Unreliable alcohol testing in a shipping safety programme.
Helander, Anders; Hagelberg, Charlotte Asker; Beck, Olof; Petrini, Björn
2009-08-10
Within a maritime alcohol and drug testing programme, a case showing an unphysiological urine ethanol concentration (235 mmol/L, 10.8 g/L) was found. The sample contained low levels of the ethanol metabolites ethyl glucuronide (EtG) and ethyl sulphate (EtS) which confirmed prior drinking, but also tested positive for the fermenting yeast Candida albicans which suggested post-sampling ethanol formation. This and other questionable cases prompted investigation of the suitability of urine alcohol testing for the intended application. Besides the routine measurements of ethanol, illicit drugs and creatinine, randomly selected ethanol-positive and ethanol-negative urines collected within the maritime programme were checked for the presence of EtG and EtS and for fungal and bacterial growth. Data on sample handling and storage was also gathered. Ten of 15 (67%) ethanol-positive and 4 of 9 (44%) ethanol-negative urines contained yeast and/or bacteria. Among the ethanol-positive cases, 4 (27%) were obviously false positives because EtG and EtS were not detected. Microbial action as the reason for false-high ethanol concentrations was indicated in other cases. When 17 bacteria-infected but fungi-negative urines were supplemented with glucose and stored for 1 week at 21 degrees C, ethanol was formed in 2 specimens containing Escherichia coli and E. coli plus P. aeruginosa. In these samples, EtG was also formed on storage while EtS was not. The routines employed for urine collection and handling within this substance abuse programme caused many false-positive identifications of alcohol use with unintended medico-legal consequences. Unpreserved urines stored without cooling should not be used for alcohol testing, given the high risk for microbial interference.
Wang, Jun; Caccamise, Sarah A L; Wu, Liejun; Woodward, Lee Ann; Li, Qing X
2011-08-01
Several nuclear tests were performed at Enewetak and Bikini Atolls in the Marshall Islands between 1946 and 1958. The events at Bikini Atoll involved several ships that were tested for durability during nuclear explosions, and 24 vessels now rest on the bottom of the Bikini lagoon. Nine soil samples were collected from different areas on the two islands of the atoll, and eighteen sediment, nine fish, and one lobster were collected in the vicinity of the sunken ships. Organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs), and polychlorinated terphenyls (PCTs) in these samples were analyzed using gas chromatography/ion trap mass spectrometry (GC/ITMS). The average recoveries ranged from 78% to 104% for the different PCB congeners. The limits of detection (LOD) for PCBs, PCTs, DDE, DDT, and dieldrin ranged 10-50 pg g(-1). Some fish from Enewetak contained PCBs at a concentration range of 37-137 ng g(-1), dry weight (dw), and most of the soils from Enewetak showed evidence of PCBs (22-392 ng g(-1)dw). Most of the Bikini lagoon sediment samples contained PCBs, and the highest was the one collected from around the Saratoga, an aircraft carrier (1555 ng g(-1)dw). Some of the fish samples, most of the soil samples, and only one of the sediment samples contained 2,2-bis(4-chlorophenyl)-1,1-dichloroethylene (DDE) and PCBs. In addition to PCBs, the soils from Enewetak Atoll contained PCTs. PCTs were not detected in the sediment samples from Bikini Atoll. The results suggest local pollution sources of PCBs, PCTs, and OCPs. Copyright © 2011. Published by Elsevier Ltd.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-20
..., closures and coils and from graphic arts operations and the provision of sampling and testing facilities...; SDCAPCD Rule 67.16, Metal Container, Graphic Arts Operations; MBUAPCD Rule 205, Provision of Sampling and...
ACER Chemistry Test Item Collection. ACER Chemtic Year 12.
ERIC Educational Resources Information Center
Australian Council for Educational Research, Hawthorn.
The chemistry test item banks contains 225 multiple-choice questions suitable for diagnostic and achievement testing; a three-page teacher's guide; answer key with item facilities; an answer sheet; and a 45-item sample achievement test. Although written for the new grade 12 chemistry course in Victoria, Australia, the items are widely applicable.…
9 CFR 113.454 - Clostridium Perfringens Type C Antitoxin.
Code of Federal Regulations, 2014 CFR
2014-01-01
... unsatisfactory by a prescribed test shall not be released. (a) Each serial shall meet the applicable general requirements provided in § 113.450. (b) Potency test. Bulk or final container samples of completed product from each serial shall be tested using the toxin-neutralization test for Beta Antitoxin provided in this...
9 CFR 113.454 - Clostridium Perfringens Type C Antitoxin.
Code of Federal Regulations, 2012 CFR
2012-01-01
... unsatisfactory by a prescribed test shall not be released. (a) Each serial shall meet the applicable general requirements provided in § 113.450. (b) Potency test. Bulk or final container samples of completed product from each serial shall be tested using the toxin-neutralization test for Beta Antitoxin provided in this...
9 CFR 113.455 - Clostridium Perfringens Type D Antitoxin.
Code of Federal Regulations, 2014 CFR
2014-01-01
... unsatisfactory by a prescribed test shall not be released. (a) Each serial shall meet the applicable general requirements provided in § 113.450. (b) Potency test. Bulk or final container samples of completed product from each serial shall be tested using the toxin-neutralization test for Epsilon Antitoxin provided in this...
9 CFR 113.455 - Clostridium Perfringens Type D Antitoxin.
Code of Federal Regulations, 2013 CFR
2013-01-01
... unsatisfactory by a prescribed test shall not be released. (a) Each serial shall meet the applicable general requirements provided in § 113.450. (b) Potency test. Bulk or final container samples of completed product from each serial shall be tested using the toxin-neutralization test for Epsilon Antitoxin provided in this...
9 CFR 113.454 - Clostridium Perfringens Type C Antitoxin.
Code of Federal Regulations, 2013 CFR
2013-01-01
... unsatisfactory by a prescribed test shall not be released. (a) Each serial shall meet the applicable general requirements provided in § 113.450. (b) Potency test. Bulk or final container samples of completed product from each serial shall be tested using the toxin-neutralization test for Beta Antitoxin provided in this...
9 CFR 113.455 - Clostridium Perfringens Type D Antitoxin.
Code of Federal Regulations, 2012 CFR
2012-01-01
... unsatisfactory by a prescribed test shall not be released. (a) Each serial shall meet the applicable general requirements provided in § 113.450. (b) Potency test. Bulk or final container samples of completed product from each serial shall be tested using the toxin-neutralization test for Epsilon Antitoxin provided in this...
Benefaction studies on the Hasan Celebi magnetite deposit, Turkey
Pressler, Jean W.; Akar, Ali
1972-01-01
Bench-scale and semicontinuous tests were performed on surface, trench, and diamond drill core samples from the Hasan Celebi low-grade magnetite deposit to determine the optimum benefication procedures utilizing wet magnetic separation techniques. Composite core samples typically contain about 27 percent recoverable magnetite and require crushing and grinding through 1 mm in size to insure satisfactory separation of the gangue from the magnetite. Regrinding and cleaning the magnetite concentrate to 80 percent minus 150-mesh is necessary to obtain an optimum of 66 percent iron. Semicontinuous pilot-plant testing with the wet magnetic drum using the recycled middling technique indicates that as much as 83 percent of the acid-soluble iron can be recovered into a concentrate containing 66 percent iron, with minimum deleterious elements. This represents 27 weight percent of the original ore. Further tests will continue when the Maden Tetkik ve Arama Enstitusu (MTA) receives 24 tons of bulk sample from an exploratory drift and cross-cut now being driven through a section of the major reserve area.
Remineralization Property of an Orthodontic Primer Containing a Bioactive Glass with Silver and Zinc
Lee, Seung-Min; Kim, In-Ryoung; Park, Bong-Soo; Ko, Ching-Chang; Son, Woo-Sung; Kim, Yong-Il
2017-01-01
White spot lesions (WSLs) are irreversible damages in orthodontic treatment due to excessive etching or demineralization by microorganisms. In this study, we conducted a mechanical and cell viability test to examine the antibacterial properties of 0.2% and 1% bioactive glass (BAG) and silver-doped and zinc-doped BAGs in a primer and evaluated their clinical applicability to prevent WSLs. The microhardness statistically significantly increased in the adhesive-containing BAG, while the other samples showed no statistically significant difference compared with the control group. The shear bond strength of all samples increased compared with that of the control group. The cell viability of the control and sample groups was similar within 24 h, but decreased slightly over 48 h. All samples showed antibacterial properties. Regarding remineralization property, the group containing 0.2% of the samples showed remineralization properties compared with the control group, but was not statistically significant; further, the group containing 1% of the samples showed a significant difference compared with the control group. Among them, the orthodontic bonding primer containing 1% silver-doped BAG showed the highest remineralization property. The new orthodontic bonding primer used in this study showed an antimicrobial effect, chemical remineralization effect, and WSL prevention as well as clinically applicable properties, both physically and biologically. PMID:29088092
Jafari, Seid Mahdi; Ganje, Mohammad; Dehnad, Danial; Ghanbari, Vahid; Hajitabar, Javad
2017-12-01
The shelf life of tomato paste with microencapsulated olive leaf extract was compared with that of samples containing a commercial preservative by accelerated shelf life testing. Based on previous studies showing that olive leaf extract as a rich source of phenolic compounds can have antimicrobial properties, application of its encapsulated form to improve the storage stability of tomato paste is proposed here. Regarding total soluble solids, the control and the sample containing 1000 µg g -1 sodium benzoate had the lowest (Q 10 = 1.63) and highest (Q 10 = 1.88) sensitivity to temperature changes respectively; also, the microencapsulated sample containing 1000 µg g -1 encapsulated olive leaf extract (Q 10 = 1.83) followed the sample containing 1000 µg g -1 sodium benzoate in terms of the highest kinetic rates. In the case of consistency, the lowest and highest activation energies (E a ) corresponded to samples containing 1000 µg g -1 non-encapsulated olive leaf extract and 1000 µg g -1 microencapsulated olive leaf extract respectively. Interestingly, samples containing microencapsulated olive leaf extract could maintain the original quality of the tomato paste very well, while those with non-encapsulated olive leaf extract rated the worst performance (among all specimens) in terms of maintaining their quality indices for a long time period. Overall, the shelf life equation was able to predict the consistency index of all tomato paste samples during long-time storage with high precision. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Klymus, Katy E.; Richter, Cathy; Thompson, Nathan; Hinck, Jo E.
2017-01-01
Understanding how anthropogenic impacts on the landscape affect wildlife requires a knowledge of community assemblages. Species surveys are the first step in assessing community structure, and recent molecular applications such as metabarcoding and environmental DNA analyses have been proposed as an additional and complementary wildlife survey method. Here, we test eDNA metabarcoding as a survey tool to examine the potential use of uranium mine containment ponds as water sources by wildlife. We tested samples from surface water near mines and from one mine containment pond using two markers, 12S and 16S rRNA gene amplicons, to survey for vertebrate species. We recovered large numbers of sequence reads from taxa expected to be in the area and from less common or hard to observe taxa such as the tiger salamander and gray fox. Detection of these two species is of note because they were not observed in a previous species assessment, and tiger salamander DNA was found in the mine containment pond sample. We also found that sample concentration by centrifugation was a more efficient and more feasible method than filtration in these highly turbid surface waters. Ultimately, the use of eDNA metabarcoding could allow for a better understanding of the area’s overall biodiversity and community composition as well as aid current ecotoxicological risk assessment work.
Materials samples face rigors of space.
Flinn, Edward D
2002-07-01
The Materials International Space Station Experiment (MISSE) is described. This project is designed to conduct long duration materials tests on samples attached to the ISS. A batch of 750 material samples were delivered on STS-105 and attached to the ISS airlock. They will be exposed to the space environment for 18 months and are slated to return on STS-114. A second batch of 750 samples is being prepared. The experiment containers were used originally for the Mir Environmental Effects Payload, which tested a variety of substances, including some slated for use on the ISS. Researchers are particularly interested in the effects of atomic oxygen on the samples. Some samples are being tested to determine their use in radiation protection. As part of the MISSE project, ultrathin tether materials are being tested for use on the Propulsive Small Expendable Depoloyer System (ProSEDS), which will use a tether system to change a satellite's orbital altitude.
Faria, Elsa Correia; Treves Brown, Bernard J; Snook, Richard D
2004-02-01
In this paper the kinetic method for the determination of toxicity using Vibrio fischeri is described and suggested as a potential method for the continuous screening of wastewater toxicity. The kinetic method was demonstrated to be free from interferences due to colour and turbidity normally observed when testing wastewater samples with this organism. This is of great importance for the application of the method to remote toxicity screening of wastewaters. The effect of colour, investigated using 50 ppm Zn(2+) solutions containing the food-dye tropaeolin O, and the effect of turbidity, investigated using 50 ppm Zn(2+) solutions containing white optically reflective and coloured optically absorbing polystyrene beads, is reported. It was also found that the design of the light detection system of the instrument ensures efficient collection of the light scattered by particles in the sample, which enables a greater range of turbid samples to be tested. In addition the natural light decay was found to be negligible during the duration of a 10 min test and thus one channel would be enough to carry out the tests. This would mean halving the quantity of bacterial reagent used and reducing the cost of the tests.
ERIC Educational Resources Information Center
Quinino, Roberto C.; Reis, Edna A.; Bessegato, Lupercio F.
2013-01-01
This article proposes the use of the coefficient of determination as a statistic for hypothesis testing in multiple linear regression based on distributions acquired by beta sampling. (Contains 3 figures.)
A Raman Spectroscopic Study of Samples from the May 2001 FIDO Test Site
NASA Technical Reports Server (NTRS)
Kuebler, K.; Jolliff, B. L.; Wang, A.; Haskin, L. A.
2002-01-01
Last May, a rover field test was conducted in the Mojave desert. This study shows what mineralogy a rover-deployed Raman spectrometer might have observed. Additional information is contained in the original extended abstract.
High temperature aqueous stress corrosion testing device
Bornstein, A.N.; Indig, M.E.
1975-12-01
A description is given of a device for stressing tensile samples contained within a high temperature, high pressure aqueous environment, thereby permitting determination of stress corrosion susceptibility of materials in a simple way. The stressing device couples an external piston to an internal tensile sample via a pull rod, with stresses being applied to the sample by pressurizing the piston. The device contains a fitting/seal arrangement including Teflon and weld seals which allow sealing of the internal system pressure and the external piston pressure. The fitting/seal arrangement allows free movement of the pull rod and the piston.
Technology Development and Advanced Planning for Curation of Returned Mars Samples
NASA Technical Reports Server (NTRS)
Lindstrom, David J.; Allen, Carlton C.
2002-01-01
NASA Johnson Space Center (JSC) curates extraterrestrial samples, providing the international science community with lunar rock and soil returned by the Apollo astronauts, meteorites collected in Antarctica, cosmic dust collected in the stratosphere, and hardware exposed to the space environment. Curation comprises initial characterization of new samples, preparation and allocation of samples for research, and clean, secure long-term storage. The foundations of this effort are the specialized cleanrooms (class 10 to 10,000) for each of the four types of materials, the supporting facilities, and the people, many of whom have been doing detailed work in clean environments for decades. JSC is also preparing to curate the next generation of extraterrestrial samples. These include samples collected from the solar wind, a comet, and an asteroid. Early planning and R\\&D are underway to support post-mission sample handling and curation of samples returned from Mars. One of the strong scientific reasons for returning samples from Mars is to search for evidence of current or past life in the samples. Because of the remote possibility that the samples may contain life forms that are hazardous to the terrestrial biosphere, the National Research Council has recommended that all samples returned from Mars be kept under strict biological containment until tests show that they can safely be released to other laboratories. It is possible that Mars samples may contain only scarce or subtle traces of life or prebiotic chemistry that could readily be overwhelmed by terrestrial contamination . Thus, the facilities used to contain, process, and analyze samples from Mars must have a combination of high-level biocontainment and organic / inorganic chemical cleanliness that is unprecedented. JSC has been conducting feasibility studies and developing designs for a sample receiving facility that would offer biocontainment at least the equivalent of current maximum containment BSL-4 (BioSafety Level 4) laboratories, while simultaneously maintaining cleanliness levels equaling those of state-of-the-art cleanrooms. Unique requirements for the processing of Mars samples have inspired a program to develop handling techniques that are much more precise and reliable than the approach (currently used for lunar samples) of employing gloved human hands in nitrogen-filled gloveboxes. Individual samples from Mars are expected to be much smaller than lunar samples, the total mass of samples returned by each mission being 0.5- 1 kg, compared with many tens of kg of lunar samples returned by each of the six Apollo missions. Smaller samples require much more of the processing to be done under microscopic observation. In addition, the requirements for cleanliness and high-level containment would be difficult to satisfy while using traditional gloveboxes. JSC has constructed a laboratory to test concepts and technologies important to future sample curation. The Advanced Curation Laboratory includes a new-generation glovebox equipped with a robotic arm to evaluate the usability of robotic and teleoperated systems to perform curatorial tasks. The laboratory also contains equipment for precision cleaning and the measurement of trace organic contamination.
Technology Development and Advanced Planning for Curation of Returned Mars Samples
NASA Astrophysics Data System (ADS)
Lindstrom, D. J.; Allen, C. C.
2002-05-01
NASA/Johnson Space Center (JSC) curates extraterrestrial samples, providing the international science community with lunar rock and soil returned by the Apollo astronauts, meteorites collected in Antarctica, cosmic dust collected in the stratosphere, and hardware exposed to the space environment. Curation comprises initial characterization of new samples, preparation and allocation of samples for research, and clean, secure long-term storage. The foundations of this effort are the specialized cleanrooms (class 10 to 10,000) for each of the four types of materials, the supporting facilities, and the people, many of whom have been doing detailed work in clean environments for decades. JSC is also preparing to curate the next generation of extraterrestrial samples. These include samples collected from the solar wind, a comet, and an asteroid. Early planning and R&D are underway to support post-mission sample handling and curation of samples returned from Mars. One of the strong scientific reasons for returning samples from Mars is to search for evidence of current or past life in the samples. Because of the remote possibility that the samples may contain life forms that are hazardous to the terrestrial biosphere, the National Research Council has recommended that all samples returned from Mars be kept under strict biological containment until tests show that they can safely be released to other laboratories. It is possible that Mars samples may contain only scarce or subtle traces of life or prebiotic chemistry that could readily be overwhelmed by terrestrial contamination. Thus, the facilities used to contain, process, and analyze samples from Mars must have a combination of high-level biocontainment and organic / inorganic chemical cleanliness that is unprecedented. JSC has been conducting feasibility studies and developing designs for a sample receiving facility that would offer biocontainment at least the equivalent of current maximum containment BSL-4 (BioSafety Level 4) laboratories, while simultaneously maintaining cleanliness levels equaling those of state-of-the-art cleanrooms. Unique requirements for the processing of Mars samples have inspired a program to develop handling techniques that are much more precise and reliable than the approach (currently used for lunar samples) of employing gloved human hands in nitrogen-filled gloveboxes. Individual samples from Mars are expected to be much smaller than lunar samples, the total mass of samples returned by each mission being 0.5- 1 kg, compared with many tens of kg of lunar samples returned by each of the six Apollo missions. Smaller samples require much more of the processing to be done under microscopic observation. In addition, the requirements for cleanliness and high-level containment would be difficult to satisfy while using traditional gloveboxes. JSC has constructed a laboratory to test concepts and technologies important to future sample curation. The Advanced Curation Laboratory includes a new-generation glovebox equipped with a robotic arm to evaluate the usability of robotic and teleoperated systems to perform curatorial tasks. The laboratory also contains equipment for precision cleaning and the measurement of trace organic contamination.
9 CFR 113.452 - Erysipelothrix Rhusiopathiae Antibody.
Code of Federal Regulations, 2010 CFR
2010-01-01
... die from erysipelas within 7 days post-challenge, the test is invalid. All dead mice shall be examined... found unsatisfactory by a prescribed test shall not be released. (a) Each serial shall meet the applicable general requirements provided in § 113.450. (b) Potency test. Bulk or final container samples of...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lord, David L.; Allen, Raymond
Sandia National Laboratories is seeking access to crude oil samples for a research project evaluating crude oil combustion properties in large-scale tests at Sandia National Laboratories in Albuquerque, NM. Samples must be collected from a source location and transported to Albuquerque in a tanker that complies with all applicable regulations for transportation of crude oil over public roadways. Moreover, the samples must not gain or lose any components, to include dissolved gases, from the point of loading through the time of combustion at the Sandia testing facility. In order to achieve this, Sandia designed and is currently procuring a custommore » tanker that utilizes water displacement in order to achieve these performance requirements. The water displacement procedure is modeled after the GPA 2174 standard “Obtaining Liquid Hydrocarbons Samples for Analysis by Gas Chromatography” (GPA 2014) that is used routinely by crude oil analytical laboratories for capturing and testing condensates and “live” crude oils, though it is practiced at the liter scale in most applications. The Sandia testing requires 3,000 gallons of crude. As such, the water displacement method will be upscaled and implemented in a custom tanker. This report describes the loading process for acquiring a ~3,000 gallon crude oil sample from commercial process piping containing single phase liquid crude oil at nominally 50-100 psig. This document contains a general description of the process (Section 2), detailed loading procedure (Section 3) and associated oil testing protocols (Section 4).« less
Directional spectral emissivity measurement system
NASA Technical Reports Server (NTRS)
Halyo, Nesim (Inventor); Pandey, Dhirendra K. (Inventor)
1992-01-01
Apparatus and process for determining the emissivity of a test specimen including an integrated sphere having two concentric walls with a coolant circulating therebetween, and disposed within a chamber which may be under ambient, vacuum or inert gas conditions. A reference sample is disposed within the sphere with a monochromatic light source in optical alignment therewith. A pyrometer is in optical alignment with the test sample for obtaining continuous test sample temperature measurements during a test. An arcuate slit port is provided through the spaced concentric walls of the integrating sphere with a movable monochromatic light source extending through and movable along the arcuate slit port. A detector system extends through the integrating sphere for continuously detecting an integrated signal indicative of all radiation within its field of view, as a function of the emissivity of the test specimen at various temperatures and various angle position of the monochromatic light source. A furnace for heating the test sample to approximately 3000 K. and control mechanism for transferring the heated sample from the furnace to the test sample port in the integrating sphere is also contained within the chamber.
Screening of ground water samples for volatile organic compounds using a portable gas chromatograph
Buchmiller, R.C.
1989-01-01
A portable gas chromatograph was used to screen 32 ground water samples for volatile organic compounds. Seven screened samples were positive; four of the seven samples had volatile organic substances identified by second-column confirmation. Four of the seven positive, screened samples also tested positive in laboratory analyses of duplicate samples. No volatile organic compounds were detected in laboratory analyses of samples that headspace screening indicated to be negative. Samples that contained volatile organic compounds, as identified by laboratory analysis, and that contained a volatile organic compound present in a standard of selected compounds were correctly identified by using the portable gas chromatography. Comparisons of screened-sample data with laboratory data indicate the ability to detect selected volatile organic compounds at concentrations of about 1 microgram per liter in the headspace of water samples by use of a portable gas chromatography. -Author
Small-scale thermal studies of volatile homemade explosives
Sandstrom, Mary M.; Brown, Geoffrey W.; Warner, Kirsten F.; ...
2016-01-26
Several homemade or improvised explosive mixtures that either contained volatile components or produced volatile products were examined using standard small-scale safety and thermal (SSST) testing that employed differential scanning calorimetry (DSC) techniques (constant heating rate and standard sample holders). KClO 3 and KClO 4 mixtures with dodecane exhibited different enthalpy behavior when using a vented sample holder in contrast to a sealed sample holder. The standard configuration produced profiles that exhibited only endothermic transitions. The sealed system produced profiles that exhibited additional exothermic transitions absent in the standard configuration produced profiles. When H 2O 2/fuel mixtures were examined, the volatilizationmore » of the peroxide (endothermic) dominated the profiles. When a sealed sample holder was used, the energetic releases of the mixture could be clearly observed. For AN and AN mixtures, the high temperature decomposition appears as an intense endothermic event. Using a nominally sealed sample holder also did not adequately contain the system. Only when a high-pressure rated sample holder was used the high temperature decomposition of the AN could be detected as an exothermic release. The testing was conducted during a proficiency (or round-robin type) test that included three U.S. Department of Energy and two U.S. Department of Defense laboratories. In the course of this proficiency test, certain HMEs exhibited thermal behavior that was not adequately accounted for by standard techniques. Further examination of this atypical behavior highlighted issues that may have not been recognized previously because some of these materials are not routinely tested. More importantly, if not recognized, the SSST testing results could lead to inaccurate safety assessments. Furthermore, this study provides examples, where standard techniques can be applied, and results can be obtained, but these results may be misleading in establishing thermal properties.« less
Whole Module Offgas Test Report: Space-X Dragon Module
NASA Technical Reports Server (NTRS)
James, John T.
2012-01-01
Between 7 April and 11 April 2012 a chemist from the JSC Toxicology Group acquired samples of air in 500 ml evacuated canisters from the sealed Dragon Module at the Space-X facility at KSC. Three samples were taken of facility air (two before the test and one after the test), and a total of 9 samples were taken from the sealed module in triplicate at the following times: 0 hours, 48 hours, and 96 hours. The module contained 470 kg, which was 100% of the mass to be launched. Analytical data contained in the Toxicology Group Report (attached) show that the ambient facility air was clean except for almost 9 milligrams per cubic meter of isopropanol (IPA) in the sample taken at the end of the test. Space-X must ensure that IPA is not introduced into the module before it is sealed for launch. Other minor contaminants in the ambient air included the following: perfluoro(2-methyl)pentane and hexamethylcyclotrisiloxane. The first-acquired samples of each triplicate from the module were not analyzed. Analyses of pairs of samples that were taken during the test show excellent agreement between the pairs and a linear increase in the T-values during the 4 days of the test (figure below). The rate of increase averaged 0.124 T units per day. If the time from last purge of the module on the ground to crew first entry on orbit is 10 days, then the T value at first entry should be less than 1.2 units, which is well below the criterion of 3.0 for consideration of additional protection of the crew from offgas products. The primary contributors were as follows: trimethylsilanol (0.057), fluorotrimethylsilane (0.047), acetaldehyde (0.004), hexamethylcyclopentasiloxane (0.003), and toluene (0.002).
Selection of 3013 Containers for Field Surveillance. Fiscal Year 2016 Update
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, Elizabeth J.; Berg, John M.; Cheadle, Jesse
2016-04-19
This update is the eighth in a series of reports that document the binning and sample selection of 3013 containers for the Field Surveillance program as part of the Integrated Surveillance Program. This report documents changes made to both the container binning assignments and the sample selection approach. Binning changes documented in this update are a result of changes to the prompt gamma calibration curves and the reassignment of a small number of Hanford items from the Pressure bin to the Pressure and Corrosion (P&C) bin. Field Surveillance sample selection changes are primarily a result of focusing future destructive examinationsmore » (DEs) on the potential for stress corrosion cracking in higher moisture containers in the P&C bin. The decision to focus the Field Surveillance program on higher moisture items is based on findings from both the Shelf-life testing program and DEs.« less
Scholtens, Ingrid; Laurensse, Emile; Molenaar, Bonnie; Zaaijer, Stephanie; Gaballo, Heidi; Boleij, Peter; Bak, Arno; Kok, Esther
2013-09-25
Nowadays most animal feed products imported into Europe have a GMO (genetically modified organism) label. This means that they contain European Union (EU)-authorized GMOs. For enforcement of these labeling requirements, it is necessary, with the rising number of EU-authorized GMOs, to perform an increasing number of analyses. In addition to this, it is necessary to test products for the potential presence of EU-unauthorized GMOs. Analysis for EU-authorized and -unauthorized GMOs in animal feed has thus become laborious and expensive. Initial screening steps may reduce the number of GMO identification methods that need to be applied, but with the increasing diversity also screening with GMO elements has become more complex. For the present study, the application of an informative detailed 24-element screening and subsequent identification strategy was applied in 50 animal feed samples. Almost all feed samples were labeled as containing GMO-derived materials. The main goal of the study was therefore to investigate if a detailed screening strategy would reduce the number of subsequent identification analyses. An additional goal was to test the samples in this way for the potential presence of EU-unauthorized GMOs. Finally, to test the robustness of the approach, eight of the samples were tested in a concise interlaboratory study. No significant differences were found between the results of the two laboratories.
Metal ion release from silver soldering and laser welding caused by different types of mouthwash.
Erdogan, Ayse Tuygun; Nalbantgil, Didem; Ulkur, Feyza; Sahin, Fikrettin
2015-07-01
To compare metal ion release from samples welded with silver soldering and laser welding when immersed into mouthwashes with different ingredients. A total of 72 samples were prepared: 36 laser welded and 36 silver soldered. Four samples were chosen from each subgroup to study the morphologic changes on their surfaces via scanning electron microscopy (SEM). Each group was further divided into four groups where the samples were submerged into mouthwash containing sodium fluoride (NaF), mouthwash containing sodium fluoride + alcohol (NaF + alcohol), mouthwash containing chlorhexidine (CHX), or artificial saliva (AS) for 24 hours and removed thereafter. Subsequently, the metal ion release from the samples was measured with inductively coupled plasma mass spectrometry (ICP-MS). The metal ion release among the solutions and the welding methods were compared. The Kruskal-Wallis and analysis of variance (ANOVA) tests were used for the group comparisons, and post hoc Dunn multiple comparison test was utilized for the two group comparisons. The level of metal ion release from samples of silver soldering was higher than from samples of laser welding. Furthermore, greater amounts of nickel, chrome, and iron were released from silver soldering. With regard to the mouthwash solutions, the lowest amounts of metal ions were released in CHX, and the highest amounts of metal ions were released in NaF + alcohol. SEM images were in accord with these findings. The laser welding should be preferred over silver soldering. CHX can be recommended for patients who have welded appliances for orthodontic reasons.
Turkec, Aydin; Lucas, Stuart J; Karlık, Elif
2016-07-01
EU legislation strictly controls use of genetically modified (GM) crops in food and feed products, and requires them to be labelled if the total GM content is greater than 9 g kg(-1) (for approved GM crops). We screened maize-containing food and feed products from Turkey to assess the prevalence of GM material. With this aim, 83 food and feed products - none labelled as containing GM material - were screened using multiplex real-time polymerase chain reaction (PCR) for four common GM elements (35S/NOS/bar/FMV). Of these, 18.2% of feeds and 6% of food samples tested positive for one or more of these elements, and were subjected to event-specific PCR to identify which GM organisms they contained. Most samples were negative for the approved GM events tested, suggesting that they may contain adventitious GM contaminants. One sample was shown to contain an unapproved GM event (MON810, along with GA21) at a concentration well above the statutory labelling requirement. Current legislation has restricted the penetration of GM maize into the Turkish food industry but not eliminated it, and the proliferation of different GM events is making monitoring increasingly complex. Our results indicate that labelling requirements are not being followed in some cases. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.
Hydraulically controlled discrete sampling from open boreholes
Harte, Philip T.
2013-01-01
Groundwater sampling from open boreholes in fractured-rock aquifers is particularly challenging because of mixing and dilution of fluid within the borehole from multiple fractures. This note presents an alternative to traditional sampling in open boreholes with packer assemblies. The alternative system called ZONFLO (zonal flow) is based on hydraulic control of borehole flow conditions. Fluid from discrete fractures zones are hydraulically isolated allowing for the collection of representative samples. In rough-faced open boreholes and formations with less competent rock, hydraulic containment may offer an attractive alternative to physical containment with packers. Preliminary test results indicate a discrete zone can be effectively hydraulically isolated from other zones within a borehole for the purpose of groundwater sampling using this new method.
Diffusive sampling of 1,3-butadiene for 24 hours onto the graphitic adsorbent Carbopack X contained in a stainless steel tube badge (6.3 mm OD, 5 mm ID, and 90 mm in length) with analysis by thermal desorption/GC/MS has been evaluated in controlled tests. A test matrix of 42 tr...
Rural drinking water at supply and household levels: quality and management.
Hoque, Bilqis A; Hallman, Kelly; Levy, Jason; Bouis, Howarth; Ali, Nahid; Khan, Feroze; Khanam, Sufia; Kabir, Mamun; Hossain, Sanower; Shah Alam, Mohammad
2006-09-01
Access to safe drinking water has been an important national goal in Bangladesh and other developing countries. While Bangladesh has almost achieved accepted bacteriological drinking water standards for water supply, high rates of diarrheal disease morbidity indicate that pathogen transmission continues through water supply chain (and other modes). This paper investigates the association between water quality and selected management practices by users at both the supply and household levels in rural Bangladesh. Two hundred and seventy tube-well water samples and 300 water samples from household storage containers were tested for fecal coliform (FC) concentrations over three surveys (during different seasons). The tube-well water samples were tested for arsenic concentration during the first survey. Overall, the FC was low (the median value ranged from 0 to 4 cfu/100ml) in water at the supply point (tube-well water samples) but significantly higher in water samples stored in households. At the supply point, 61% of tube-well water samples met the Bangladesh and WHO standards of FC; however, only 37% of stored water samples met the standards during the first survey. When arsenic contamination was also taken into account, only 52% of the samples met both the minimum microbiological and arsenic content standards of safety. The contamination rate for water samples from covered household storage containers was significantly lower than that of uncovered containers. The rate of water contamination in storage containers was highest during the February-May period. It is shown that safe drinking water was achieved by a combination of a protected and high quality source at the initial point and maintaining quality from the initial supply (source) point through to final consumption. It is recommended that the government and other relevant actors in Bangladesh establish a comprehensive drinking water system that integrates water supply, quality, handling and related educational programs in order to ensure the safety of drinking water supplies.
The use of hydrated lime as an antistripping additive : final report.
DOT National Transportation Integrated Search
1987-01-01
The purpose of this investigation was to evaluate the performance of six test sections of asphalt concrete that contained no additive, hydrated lime, and a chemical additive. Tests were also conducted on pavement samples taken periodically to determi...
Glove permeation by semiconductor processing mixtures containing glycol-ether derivatives.
Zellers, E T; Ke, H Q; Smigiel, D; Sulewski, R; Patrash, S J; Han, M W; Zhang, G Z
1992-02-01
Results of permeation tests of several glove materials challenged with semiconductor processing formulations containing glycolether derivatives are described. Commercial glove samples of nitrile rubber (Edmont), natural rubber (Edmont and Baxter), butyl rubber (North), PVC Baxter), a natural rubber/neoprene/nitrile blend (Pioneer), and a natural rubber/neoprene blend (Playtex) were tested according to the ASTM F739-85 permeation test method (open-loop configuration). The liquid formulations examined included a positive photoresist thinner containing 2-ethoxyethyl acetate (2-EEA), n-butyl acetate, and xylene; a positive photoresist containing 2-EEA, n-butyl acetate, xylene, polymer resins, and photoactive compounds; a negative photoresist containing 2-methoxyethanol (2-ME), xylene, and cyclized poly(isoprene); and pure 2-methoxyethyl acetate (2-MEA), which is the solvent used in a commercial electron-beam resist. With the exception of the negative photoresist, butyl rubber provided the highest level of protection against the solvent mixtures tested, with no breakthrough observed after 4 hr of continuous exposure at 25 degrees C. Nitrile rubber provided the highest level of protection against the negative photoresist and reasonably good protection against initial exposure to the other solvent mixtures. Gloves consisting of natural rubber or natural rubber blends provided less protection against the mixtures than either nitrile or butyl rubber. For most of the glove samples, permeation of the glycol-ether derivatives contained in the mixtures was faster than that predicted from the permeation of the pure solvents. Increasing the exposure temperature from 25 to 37 degrees C did not significantly affect the performance of the butyl rubber glove. For the other gloves, however, exposures at 37 degrees C resulted in decreases in breakthrough times of 25-75% and increases in steady-state permeation rates of 80-457% relative to values obtained at 25 degrees C. Repeated exposure of nitrile rubber samples resulted in shorter breakthrough times for all mixture components. In fact, exposure for as little as one-half of the nominal breakthrough time followed by air drying overnight resulted in measurable quantities of one or more of the component solvents at the inner surface of the gloves at the beginning of the next exposure. This effect was not observed with the butyl rubber samples. With the exception of the negative photoresist, heating previously exposed nitrile rubber samples at 70 degrees C for 20 hr prior to retesting reduced or eliminated the effects of residual solvents, permitting reuse of the gloves. The use of thin PVC or natural rubber gloves adjacent to the nitrile gloves provided moderate increases in permeation resistance.(ABSTRACT TRUNCATED AT 400 WORDS)
Environmental Survey of Drinking Water Sources in Kampala, Uganda, during a Typhoid Fever Outbreak
Kahler, A. M.; Nansubuga, I.; Nanyunja, E. M.; Kaplan, B.; Jothikumar, N.; Routh, J.; Gómez, G. A.; Mintz, E. D.; Hill, V. R.
2017-01-01
ABSTRACT In 2015, a typhoid fever outbreak began in downtown Kampala, Uganda, and spread into adjacent districts. In response, an environmental survey of drinking water source types was conducted in areas of the city with high case numbers. A total of 122 samples was collected from 12 source types and tested for Escherichia coli, free chlorine, and conductivity. An additional 37 grab samples from seven source types and 16 paired large volume (20 liter) samples from wells and springs were also collected and tested for the presence of Salmonella enterica serovar Typhi. Escherichia coli was detected in 60% of kaveras (drinking water sold in plastic bags) and 80% of refilled water bottles; free chlorine was not detected in either source type. Most jerry cans (68%) contained E. coli and had free chlorine residuals below the WHO-recommended level of 0.5 mg/liter during outbreaks. Elevated conductivity readings for kaveras, refilled water bottles, and jerry cans (compared to treated surface water supplied by the water utility) suggested that they likely contained untreated groundwater. All unprotected springs and wells and more than 60% of protected springs contained E. coli. Water samples collected from the water utility were found to have acceptable free chlorine levels and no detectable E. coli. While S. Typhi was not detected in water samples, Salmonella spp. were detected in samples from two unprotected springs, one protected spring, and one refilled water bottle. These data provided clear evidence that unregulated vended water and groundwater represented a risk for typhoid transmission. IMPORTANCE Despite the high incidence of typhoid fever globally, relatively few outbreak investigations incorporate drinking water testing. During waterborne disease outbreaks, measurement of physical-chemical parameters, such as free chlorine residual and electrical conductivity, and of microbiological parameters, such as the presence of E. coli or the implicated etiologic agent, in drinking water samples can identify contaminated sources. This investigation indicated that unregulated vended water and groundwater sources were contaminated and were therefore a risk to consumers during the 2015 typhoid fever outbreak in Kampala. Identification of contaminated drinking water sources and sources that do not contain adequate disinfectant levels can lead to rapid targeted interventions. PMID:28970225
A tubular-coring device for use in biogeochemical sampling of succulent and pulpy plants
Campbell, W.L.
1986-01-01
A hand-operated, tubular-coring device developed for use in biogeochemical sampling of succulent and pulpy plants is described. The sampler weighs about 500 g (1.1 lb); and if 25 ?? 175 mm (1 ?? 7 in) screw-top test tubes are used as sample containers, the complete sampling equipment kit is easily portable, having both moderate bulk and weight. ?? 1986.
Kappel, Kristina; Haase, Ilka; Käppel, Christine; Sotelo, Carmen G; Schröder, Ute
2017-11-01
Conventional Sanger sequencing of PCR products is the gold standard for species authentication of seafood products. However, this method is inappropriate for the analysis of products that might contain mixtures of species, such as tinned tuna. The purpose of this study was to test whether next-generation sequencing (NGS) can be a solution for the authentication of mixed products. Nine tuna samples containing mixtures of up to four species were prepared and subjected to an NGS approach targeting two short cytochrome b gene (cytb) fragments on the Illumina MiSeq platform. Sequence recovery was precise and admixtures of as low as 1% could be identified, depending on the species composition of the mixtures. Duplicate samples as well as two individual NGS runs produced very similar results. A first test of three commercial tinned tuna samples indicated the presence of different species in the same tin, although this is forbidden by EU law. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Hugues, Jonathan; Andrieu, Eric; Blanc, Christine; Cloué, Jean-Marc
The electrochemical behavior of alloy 718 in a chloride-containing boric acid solution was studied to determine the influence of chloride ions as contaminants of pool water of nuclear power plants on the corrosion behavior of the alloy. Experiments were performed at 20°C and 60°C with chloride concentrations from 1.5 to 15 000 ppm, using stationary measurements i.e. OCP versus time measurements and plotting of current-potential curves. After the electrochemical tests, the samples were observed using optical microscopy. Immersion tests in chloride-containing boric acid solutions were also carried out: samples were immersed for a time as long as 17 weeks at open circuit potential and their residual mechanical properties were measured. Results showed that, whatever the chloride concentration, there was no corrosion for samples immersed at open circuit potential. However, when the samples were polarized at high potentials, intergranular corrosion might be observed in occluded zones.
Evaluation of a Biological Pathogen Decontamination Protocol for Animal Feed Mills.
Huss, Anne R; Cochrane, Roger A; Deliephan, Aiswariya; Stark, Charles R; Jones, Cassandra K
2015-09-01
Animal feed and ingredients are potential vectors of pathogenic bacteria. Contaminated ingredients can contaminate facility equipment, leading to cross-contamination of other products. This experiment was conducted to evaluate a standardized protocol for decontamination of an animal feed manufacturing facility using Enterococcus faecium (ATCC 31282) as an indicator. A pelleted swine diet inoculated with E. faecium was manufactured, and environmental samples (swabs, replicate organism detection and counting plates, and air samples) were collected (i) before inoculation (baseline data), (ii) after production of inoculated feed, (iii) after physical removal of organic material using pressurized air, (iv) after application of a chemical sanitizer containing a quaternary ammonium-glutaraldehyde blend, (v) after application of a chemical sanitizer containing sodium hypochlorite, (vi) after facility heat-up to 60 8 C for 24 h, (vii) for 48 h, and (viii) for 72 h. Air samples collected outside the facility confirmed pathogen containment; E. faecium levels were equal to or lower than baseline levels at each sample location. The decontamination step and its associated interactions were the only variables that affected E. faecium incidence (P < 0.0001 versus P > 0.22). After production of the inoculated diet, 85.7% of environmental samples were positive for E. faecium. Physical cleaning of equipment had no effect on contamination (P = 0.32). Chemical cleaning with a quaternary ammonium-glutaraldehyde blend and sodium hypochlorite each significantly reduced E. faecium contamination (P < 0.0001) to 28.6 and 2.4% of tested surfaces, respectively. All samples were negative for E. faecium after 48 h of heating. Both wet chemical cleaning and facility heating but not physical cleaning resulted in substantial E. faecium decontamination. These results confirmed both successful containment and decontamination of biological pathogens in the tested pilot-scale feed mill.
Peck, Michael W.; Plowman, June; Aldus, Clare F.; Wyatt, Gary M.; Penaloza Izurieta, Walter; Stringer, Sandra C.; Barker, Gary C.
2010-01-01
The highly potent botulinum neurotoxins are responsible for botulism, a severe neuroparalytic disease. Strains of nonproteolytic Clostridium botulinum form neurotoxins of types B, E, and F and are the main hazard associated with minimally heated refrigerated foods. Recent developments in quantitative microbiological risk assessment (QMRA) and food safety objectives (FSO) have made food safety more quantitative and include, as inputs, probability distributions for the contamination of food materials and foods. A new method that combines a selective enrichment culture with multiplex PCR has been developed and validated to enumerate specifically the spores of nonproteolytic C. botulinum. Key features of this new method include the following: (i) it is specific for nonproteolytic C. botulinum (and does not detect proteolytic C. botulinum), (ii) the detection limit has been determined for each food tested (using carefully structured control samples), and (iii) a low detection limit has been achieved by the use of selective enrichment and large test samples. The method has been used to enumerate spores of nonproteolytic C. botulinum in 637 samples of 19 food materials included in pasta-based minimally heated refrigerated foods and in 7 complete foods. A total of 32 samples (5 egg pastas and 27 scallops) contained spores of nonproteolytic C. botulinum type B or F. The majority of samples contained <100 spores/kg, but one sample of scallops contained 444 spores/kg. Nonproteolytic C. botulinum type E was not detected. Importantly, for QMRA and FSO, the construction of probability distributions will enable the frequency of packs containing particular levels of contamination to be determined. PMID:20709854
Peck, Michael W; Plowman, June; Aldus, Clare F; Wyatt, Gary M; Izurieta, Walter Penaloza; Stringer, Sandra C; Barker, Gary C
2010-10-01
The highly potent botulinum neurotoxins are responsible for botulism, a severe neuroparalytic disease. Strains of nonproteolytic Clostridium botulinum form neurotoxins of types B, E, and F and are the main hazard associated with minimally heated refrigerated foods. Recent developments in quantitative microbiological risk assessment (QMRA) and food safety objectives (FSO) have made food safety more quantitative and include, as inputs, probability distributions for the contamination of food materials and foods. A new method that combines a selective enrichment culture with multiplex PCR has been developed and validated to enumerate specifically the spores of nonproteolytic C. botulinum. Key features of this new method include the following: (i) it is specific for nonproteolytic C. botulinum (and does not detect proteolytic C. botulinum), (ii) the detection limit has been determined for each food tested (using carefully structured control samples), and (iii) a low detection limit has been achieved by the use of selective enrichment and large test samples. The method has been used to enumerate spores of nonproteolytic C. botulinum in 637 samples of 19 food materials included in pasta-based minimally heated refrigerated foods and in 7 complete foods. A total of 32 samples (5 egg pastas and 27 scallops) contained spores of nonproteolytic C. botulinum type B or F. The majority of samples contained <100 spores/kg, but one sample of scallops contained 444 spores/kg. Nonproteolytic C. botulinum type E was not detected. Importantly, for QMRA and FSO, the construction of probability distributions will enable the frequency of packs containing particular levels of contamination to be determined.
Validation of an automated fluorescein method for determining bromide in water
Fishman, M. J.; Schroder, L.J.; Friedman, L.C.
1985-01-01
Surface, atmospheric precipitation and deionized water samples were spiked with ??g l-1 concentrations of bromide, and the solutions stored in polyethylene and polytetrafluoroethylene bottles. Bromide was determined periodically for 30 days. Automated fluorescein and ion chromatography methods were used to determine bromide in these prepared samples. Analysis of the data by the paired t-test indicates that the two methods are not significantly different at a probability of 95% for samples containing from 0.015 to 0.5 mg l-1 of bromide. The correlation coefficient for the same sets of paired data is 0.9987. Recovery data, except for the surface water samples to which 0.005 mg l-1 of bromide was added, range from 89 to 112%. There appears to be no loss of bromide from solution in either type of container.Surface, atmospheric precipitation and deionized water samples were spiked with mu g l** minus **1 concentrations of bromide, and the solutions stored in polyethylene and polytetrafluoroethylene bottles. Bromide was determined periodically for 30 days. Automated fluorescein and ion chromatography methods were used to determine bromide in these prepared samples. Analysis of the data by the paired t-test indicates that the two methods are not significantly different at a probability of 95% for samples containing from 0. 015 to 0. 5 mg l** minus **1 of bromide. The correlation coefficient for the same sets of paired data is 0. 9987. Recovery data, except for the surface water samples to which 0. 005 mg l** minus **1 of bromide was added, range from 89 to 112%. Refs.
Hydrogen recombiner catalyst test supporting data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Britton, M.D.
1995-01-19
This is a data package supporting the Hydrogen Recombiner Catalyst Performance and Carbon Monoxide Sorption Capacity Test Report, WHC-SD-WM-TRP-211, Rev 0. This report contains 10 appendices which consist of the following: Mass spectrometer analysis reports: HRC samples 93-001 through 93-157; Gas spectrometry analysis reports: HRC samples 93-141 through 93-658; Mass spectrometer procedure PNL-MA-299 ALO-284; Alternate analytical method for ammonia and water vapor; Sample log sheets; Job Safety analysis; Certificate of mixture analysis for feed gases; Flow controller calibration check; Westinghouse Standards Laboratory report on Bois flow calibrator; and Sorption capacity test data, tables, and graphs.
Regolith Volatile Recovery at Simulated Lunar Environments
NASA Technical Reports Server (NTRS)
Kleinhenz, Julie; Paulsen, Gale; Zacny, Kris; Schmidt, Sherry; Boucher, Dale
2016-01-01
Lunar Polar Volatiles: Permanently shadowed craters at the lunar poles contain water, 5 wt according to LCROSS. Interest in water for ISRU applications. Desire to ground truth water using surface prospecting e.g. Resource Prospector and RESOLVE. How to access subsurface water resources and accurately measure quantity. Excavation operations and exposure to lunar environment may affect the results. Volatile capture tests: A series a ground based dirty thermal vacuum tests are being conducted to better understand the subsurface sampling operations. Sample removal and transfer. Volatiles loss during sampling operations. Concept of operations, Instrumentation. This presentation is a progress report on volatiles capture results from these tests with lunar polar drill prototype hardware.
Spectral feature characterization methods for blood stain detection in crime scene backgrounds
NASA Astrophysics Data System (ADS)
Yang, Jie; Mathew, Jobin J.; Dube, Roger R.; Messinger, David W.
2016-05-01
Blood stains are one of the most important types of evidence for forensic investigation. They contain valuable DNA information, and the pattern of the stains can suggest specifics about the nature of the violence that transpired at the scene. Blood spectral signatures containing unique reflectance or absorption features are important both for forensic on-site investigation and laboratory testing. They can be used for target detection and identification applied to crime scene hyperspectral imagery, and also be utilized to analyze the spectral variation of blood on various backgrounds. Non-blood stains often mislead the detection and can generate false alarms at a real crime scene, especially for dark and red backgrounds. This paper measured the reflectance of liquid blood and 9 kinds of non-blood samples in the range of 350 nm - 2500 nm in various crime scene backgrounds, such as pure samples contained in petri dish with various thicknesses, mixed samples with different colors and materials of fabrics, and mixed samples with wood, all of which are examined to provide sub-visual evidence for detecting and recognizing blood from non-blood samples in a realistic crime scene. The spectral difference between blood and non-blood samples are examined and spectral features such as "peaks" and "depths" of reflectance are selected. Two blood stain detection methods are proposed in this paper. The first method uses index to denote the ratio of "depth" minus "peak" over"depth" add"peak" within a wavelength range of the reflectance spectrum. The second method uses relative band depth of the selected wavelength ranges of the reflectance spectrum. Results show that the index method is able to discriminate blood from non-blood samples in most tested crime scene backgrounds, but is not able to detect it from black felt. Whereas the relative band depth method is able to discriminate blood from non-blood samples on all of the tested background material types and colors.
Assessment of drinking water quality using indicator bacteria and bacteriophages.
Méndez, Javier; Audicana, Ana; Cancer, Mercedes; Isern, Anna; Llaneza, Julian; Moreno, Belén; Navarro, Mercedes; Tarancón, M Lluisa; Valero, Fernando; Ribas, Ferran; Jofre, Juan; Lucena, Francisco
2004-09-01
Bacterial indicators and bacteriophages suggested as potential indicators of water quality were determined by public laboratories in water from springs, household water wells, and rural and metropolitan water supplies in north-eastern Spain. Indicator bacteria were detected more frequently than bacteriophages in springs, household water wells and rural water supplies. In contrast, positive bacteriophage detections were more numerous than those of bacteria in metropolitan water supplies. Most of the metropolitan water supply samples containing indicators had concentrations of chlorine below 0.1 mg l(-1), their indicator loads resembling more closely those of rural water supplies than any other samples taken from metropolitan water supplies. The number of samples from metropolitan water supplies containing more than 0.1 mg l(-1) of chlorine that contained phages clearly outnumbered those containing indicator bacteria. Some association was observed between rainfall and the presence of indicators. Sediments from service reservoirs and water from dead ends in the distribution network of one of the metropolitan water supplies were also tested. Bacterial indicators and phages were detected in a higher percentage than in samples of tap water from the same network. Additionally, indicator bacteria were detected more frequently than bacteriophages in sediments of service reservoirs and water from dead end samples. We conclude that naturally occurring indicator bacteria and bacteriophages respond differently to chlorination and behave differently in drinking water distribution networks. Moreover, this study has shown that testing for the three groups of phages in routine laboratories is easy to implement and feasible without the requirement for additional material resources for the laboratories.
Drinking water test methods in crisis-afflicted areas: comparison of methods under field conditions.
Merle, Roswitha; Bleul, Ingo; Schulenburg, Jörg; Kreienbrock, Lothar; Klein, Günter
2011-11-01
To simplify the testing of drinking water in crisis-afflicted areas (as in Kosovo in 2007), rapid test methods were compared with the standard test. For Escherichia coli and coliform pathogens, rapid tests were made available: Colilert(®)-18, P/A test with 4-methylumbelliferyl-β-D-glucoronid, and m-Endo Broth. Biochemical differentiation was carried out by Enterotube™ II. Enterococci were determined following the standard ISO test and by means of Enterolert™. Four hundred ninety-nine water samples were tested for E. coli and coliforms using four methods. Following the standard method, 20.8% (n=104) of the samples contained E. coli, whereas the rapid tests detected between 19.6% (m-Endo Broth, 92.0% concordance) and 20.0% (concordance: 93.6% Colilert-18 and 94.8% P/A-test) positive samples. Regarding coliforms, the percentage of concordant results ranged from 98.4% (P/A-test) to 99.0% (Colilert-18). Colilert-18 and m-Endo Broth detected even more positive samples than the standard method did. Enterococci were detected in 93 of 573 samples by the standard method, but in 92 samples by Enterolert (concordance: 99.5%). Considering the high-quality equipment and time requirements of the standard method, the use of rapid tests in crisis-afflicted areas is sufficiently reliable.
The late Neandertal supraorbital fossils from Vindija Cave, Croatia: a biased sample?
Ahern, James C M; Lee, Sang-Hee; Hawks, John D
2002-09-01
The late Neandertal sample from Vindija (Croatia) has been described as transitional between the earlier Central European Neandertals from Krapina (Croatia) and modern humans. However, the morphological differences indicating this transition may rather be the result of different sex and/or age compositions between the samples. This study tests the hypothesis that the metric differences between the Krapina and Vindija supraorbital samples are due to sampling bias. We focus upon the supraorbital region because past studies have posited this region as particularly indicative of the Vindija sample's transitional nature. Furthermore, the supraorbital region varies significantly with both age and sex. We analyzed four chords and two derived indices of supraorbital torus form as defined by Smith & Ranyard (1980, Am. J. phys. Anthrop.93, pp. 589-610). For each variable, we analyzed relative sample bias of the Krapina and Vindija samples using three sampling methods. In order to test the hypothesis that the Vindija sample contains an over-representation of females and/or young while the Krapina sample is normal or also female/young biased, we determined the probability of drawing a sample of the same size as and with a mean equal to or less than Vindija's from a Krapina-based population. In order to test the hypothesis that the Vindija sample is female/young biased while the Krapina sample is male/old biased, we determined the probability of drawing a sample of the same size as and with a mean equal or less than Vindija's from a generated population whose mean is halfway between Krapina's and Vindija's. Finally, in order to test the hypothesis that the Vindija sample is normal while the Krapina sample contains an over-representation of males and/or old, we determined the probability of drawing a sample of the same size as and with a mean equal to or greater than Krapina's from a Vindija-based population. Unless we assume that the Vindija sample is female/young and the Krapina sample is male/old biased, our results falsify the hypothesis that the metric differences between the Krapina and Vindija samples are due to sample bias.
Portable tester for determining gas content within a core sample
Garcia, Jr., Fred; Schatzel, Steven J.
1998-01-01
A portable tester is provided for reading and displaying the pressure of a gas released from a rock core sample stored within a sealed container and for taking a sample of the released pressurized gas for chemical analysis thereof for subsequent use in a modified direct method test which determines the volume of gas and specific type of gas contained within the core sample. The portable tester includes a pair of low and high range electrical pressure transducers for detecting a gas pressure; a pair of low and high range display units for displaying the pressure of the detected gas- a selector valve connected to the low and high range pressure transducers, a selector knob for selecting gas flow to one of the flow paths; control valve having an inlet connection to the sealed container, and outlets connected to: a sample gas canister, a second outlet port connected to the selector valve means for reading the pressure of the gas from the sealed container to either the low range or high range pressure transducers, and a connection for venting gas contained within the sealed container to the atmosphere. A battery is electrically connected to and supplies the power for operating the unit. The pressure transducers, display units, selector and control valve means and the battery is mounted to and housed within a protective casing for portable transport and use.
Portable tester for determining gas content within a core sample
Garcia, F. Jr.; Schatzel, S.J.
1998-04-21
A portable tester is provided for reading and displaying the pressure of a gas released from a rock core sample stored within a sealed container and for taking a sample of the released pressurized gas for chemical analysis thereof for subsequent use in a modified direct method test which determines the volume of gas and specific type of gas contained within the core sample. The portable tester includes a pair of low and high range electrical pressure transducers for detecting a gas pressure; a pair of low and high range display units for displaying the pressure of the detected gas; a selector valve connected to the low and high range pressure transducers and a selector knob for selecting gas flow to one of the flow paths; control valve having an inlet connection to the sealed container; and outlets connected to: a sample gas canister, a second outlet port connected to the selector valve means for reading the pressure of the gas from the sealed container to either the low range or high range pressure transducers, and a connection for venting gas contained within the sealed container to the atmosphere. A battery is electrically connected to and supplies the power for operating the unit. The pressure transducers, display units, selector and control valve means and the battery is mounted to and housed within a protective casing for portable transport and use. 5 figs.
NASA Technical Reports Server (NTRS)
Billings, Marcus Dwight; Fasanella, Edwin L. (Technical Monitor)
2002-01-01
Nonlinear dynamic finite element simulations were performed to aid in the design of an energy-absorbing impact sphere for a passive Earth Entry Vehicle (EEV) that is a possible architecture for the Mars Sample Return (MSR) mission. The MSR EEV concept uses an entry capsule and energy-absorbing impact sphere designed to contain and limit the acceleration of collected samples during Earth impact without a parachute. The spherical shaped impact sphere is composed of solid hexagonal and pentagonal foam-filled cells with hybrid composite, graphite-epoxy/Kevlar cell walls. Collected Martian samples will fit inside a smaller spherical sample container at the center of the EEV's cellular structure. Comparisons were made of analytical results obtained using MSC.Dytran with test results obtained from impact tests performed at NASA Langley Research Center for impact velocities from 30 to 40 m/s. Acceleration, velocity, and deformation results compared well with the test results. The correlated finite element model was then used for simulations of various off-nominal impact scenarios. Off-nominal simulations at an impact velocity of 40 m/s included a rotated cellular structure impact onto a flat surface, a cellular structure impact onto an angled surface, and a cellular structure impact onto the corner of a step.
Adventitious Carbon on Primary Sample Containment Metal Surfaces
NASA Technical Reports Server (NTRS)
Calaway, M. J.; Fries, M. D.
2015-01-01
Future missions that return astromaterials with trace carbonaceous signatures will require strict protocols for reducing and controlling terrestrial carbon contamination. Adventitious carbon (AC) on primary sample containers and related hardware is an important source of that contamination. AC is a thin film layer or heterogeneously dispersed carbonaceous material that naturally accrues from the environment on the surface of atmospheric exposed metal parts. To test basic cleaning techniques for AC control, metal surfaces commonly used for flight hardware and curating astromaterials at JSC were cleaned using a basic cleaning protocol and characterized for AC residue. Two electropolished stainless steel 316L (SS- 316L) and two Al 6061 (Al-6061) test coupons (2.5 cm diameter by 0.3 cm thick) were subjected to precision cleaning in the JSC Genesis ISO class 4 cleanroom Precision Cleaning Laboratory. Afterwards, the samples were analyzed by X-ray photoelectron spectroscopy (XPS) and Raman spectroscopy.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-21
... equipment used to test cell phones and communications equipment, machines that determine the contents of... employ various analytical techniques to test samples of many types, are used by academic researchers... require the sensitivity provided by ICP-MS, and because many customers perform tests pursuant to...
Principles of Technology. Units 1-10 Pilot Test Findings.
ERIC Educational Resources Information Center
Center for Occupational Research and Development, Inc., Waco, TX.
This document provides the findings of pilot tests of 10 units for an applied science course for high school vocational students. Each of the reports on the pilot tests of the Principles of Technology units contains information on procedures, methodology limitations, sample, the pretest/posttest instrument and results, student attitude results,…
NASA Technical Reports Server (NTRS)
Phillips, G. B.; Pace, V. A., Jr.
1972-01-01
The sampler utilizes permanent magnets and soft metal pole pieces to connect the cone/filter assembly to the sampling head and vacuum supply. The cone/filter assembly is packaged in a plastic container and presterilized so that the need for any human contact during the sampling procedure is completely eliminated. Microbiological tests have demonstrated that the sampling efficiency is not affected by the magnetic coupling apparatus and that the probe appears to function as efficiently as the conventional plastic and Sandia vacuum probes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This volume contains the interim change notice for sample preparation methods. Covered are: acid digestion for metals analysis, fusion of Hanford tank waste solids, water leach of sludges/soils/other solids, extraction procedure toxicity (simulate leach in landfill), sample preparation for gamma spectroscopy, acid digestion for radiochemical analysis, leach preparation of solids for free cyanide analysis, aqueous leach of solids for anion analysis, microwave digestion of glasses and slurries for ICP/MS, toxicity characteristic leaching extraction for inorganics, leach/dissolution of activated metal for radiochemical analysis, extraction of single-shell tank (SST) samples for semi-VOC analysis, preparation and cleanup of hydrocarbon- containing samples for VOCmore » and semi-VOC analysis, receiving of waste tank samples in onsite transfer cask, receipt and inspection of SST samples, receipt and extrusion of core samples at 325A shielded facility, cleaning and shipping of waste tank samplers, homogenization of solutions/slurries/sludges, and test sample preparation for bioassay quality control program.« less
Performance of laser glazed Zr02 TBCs in cyclic oxidation and corrosion burner test rigs
NASA Technical Reports Server (NTRS)
Zaplatynsky, I.
1982-01-01
The performance of laser glazed zirconia thermal barrier coatings (TBCs) was evaluated in cyclic oxidation and cyclic corrosion tests. Plasma sprayed zirconia coatings of two thicknesses were partially melted with a CO2 laser. The power density of the focused laser beam was varied from 35 to 75 W/sq mm, while the scanning speed was about 80 cm per minute. In cyclic oxidation tests, the specimens were heated in a burner rig for 6 minutes and cooled for 3 minutes. It is indicated that the laser treated samples have the same life as the untreated ones. However, in corrosion tests, in which the burner rig flame contained 100 PPM sodium fuel equivalent, the laser treated samples exhibit nearly a fourfold life improvement over that of the reference samples vary. In both tests, the lives of the samples inversely with the thickness of the laser melted layer of zirconia.
The GSFC Mark-2 three band hand-held radiometer. [thematic mapper for ground truth data collection
NASA Technical Reports Server (NTRS)
Tucker, C. J.; Jones, W. H.; Kley, W. A.; Sundstrom, G. J.
1980-01-01
A self-contained, portable, hand-radiometer designed for field usage was constructed and tested. The device, consisting of a hand-held probe containing three sensors and a strap supported electronic module, weighs 4 1/2 kilograms. It is powered by flashlight and transistor radio batteries, utilizes two silicon and one lead sulfide detectors, has three liquid crystal displays, sample and hold radiometric sampling, and its spectral configuration corresponds to LANDSAT-D's thematic mapper bands. The device was designed to support thematic mapper ground-truth data collection efforts and to facilitate 'in situ' ground-based remote sensing studies of natural materials. Prototype instruments were extensively tested under laboratory and field conditions with excellent results.
A BATTERY-OPERATED AIR SAMPLER FOR REMOTE AREAS
An air sampling system developed to evaluate air quality in biosphere reserves or in other remote areas is described. The equipment consists of a Dupont P-4000 pump and a specially designed battery pack containing Gates batteries. This air sampling system was tested in Southern U...
Application of Lemongrass Oil-Containing Polylactic Acid Films to the Packaging of Pork Sausages.
Yang, Hyun-Ju; Song, Kyung Bin
2016-01-01
Polylactic acid (PLA) is a biodegradable and renewable polymer, which represents a valuable alternative to plastic packaging films, often associated with environmental problems. In this study, we tested the suitability of PLA as a biodegradable packaging film and assessed the antimicrobial activity of lemongrass oil (LO), incorporated into the PLA film in different concentrations. To obtain the optimal physical properties for PLA films, tensile strength, elongation at break, and water vapor permeability were measured under different preparation conditions. In addition, the antimicrobial activity of the LO contained in the PLA film against Listeria monocytogenes was investigated by disc diffusion and viable cell count. Among all concentrations tested, 2% LO was the most suitable in terms of antimicrobial activity and physical properties of the PLA film. Based on these results, we used the PLA film containing 2% LO to pack pork sausages; after 12 d of storage at 4℃, the population of inoculated L. monocytogenes in the sausage samples wrapped with the PLA film containing 2% LO was reduced by 1.47 Log CFU/g compared with the control samples. Our data indicate that PLA films containing 2% LO represent a valuable means for antimicrobial sausage packaging.
Application of Lemongrass Oil-Containing Polylactic Acid Films to the Packaging of Pork Sausages
2016-01-01
Polylactic acid (PLA) is a biodegradable and renewable polymer, which represents a valuable alternative to plastic packaging films, often associated with environmental problems. In this study, we tested the suitability of PLA as a biodegradable packaging film and assessed the antimicrobial activity of lemongrass oil (LO), incorporated into the PLA film in different concentrations. To obtain the optimal physical properties for PLA films, tensile strength, elongation at break, and water vapor permeability were measured under different preparation conditions. In addition, the antimicrobial activity of the LO contained in the PLA film against Listeria monocytogenes was investigated by disc diffusion and viable cell count. Among all concentrations tested, 2% LO was the most suitable in terms of antimicrobial activity and physical properties of the PLA film. Based on these results, we used the PLA film containing 2% LO to pack pork sausages; after 12 d of storage at 4℃, the population of inoculated L. monocytogenes in the sausage samples wrapped with the PLA film containing 2% LO was reduced by 1.47 Log CFU/g compared with the control samples. Our data indicate that PLA films containing 2% LO represent a valuable means for antimicrobial sausage packaging. PMID:27433114
Investigation Into Shelf Life of Fresh Dates and Pistachios in a Package Modified With Nano-Silver.
Mousavi, Fateme Peyro; Pour, Hasan Hashemi; Nasab, Amir Heidari; Rajabalipour, Ali A; Barouni, Mohsen
2015-09-18
The aim of this study was to apply polymer films containing silver nanoparticles as a new method for increasing the shelf life and preserving the quality of export/commercial products of Kerman Province and determine the ideal temperature for preserving these products. After preparing nano-composite films containing silver nanoparticles (3% and 5% by weight), Mazafati dates were packed in them and stored with their control samples under four temperatures. In the second series, the films were filled with fresh pistachios and stored at four temperatures. In date samples, after 2, 7, 21 and 53 days of storing the samples were examined under the certified test of Iran Institute of Industrial Standard for Dates, which includes pH, TSS, acidity and reducing sugars tests. In pistachio samples the color values and market-friendly quality were evaluated after 1, 2, 3, 6, 7 and 8 days of storage. In date samples, the pH value decreased with increasing acidity in 3 and 5 wt% of nano-silver and their control samples. In addition, in 5 wt% samples the acidity was higher than that in 3% samples, with pH being lower in the controls at almost all the intervals. Furthermore, pH values in 5% samples were higher in comparison with 3 wt% samples and controls. The amount of reducing sugars in the control samples was lower than those in 3 and 5 wt% samples. In relation to pistachio samples, the damage over time was greater in sample stored under higher temperatures. The maximum shelf life of the dates packaged in 5 wt% of silver nano-powder was 53 days and the best temperature to store samples was determined at 4°C. Packages containing nano-silver increased shelf life of fresh pistachios, with the best temperatures being 25°C and 0°C.
Investigation Into Shelf Life of Fresh Dates and Pistachios in a Package Modified With Nano-Silver
Mousavi, Fateme Peyro; Pour, Hasan Hashemi; Nasab, Amir Heidari; Rajabalipour, Ali A.; Barouni, Mohsen
2016-01-01
Aims: The aim of this study was to apply polymer films containing silver nanoparticles as a new method for increasing the shelf life and preserving the quality of export/commercial products of Kerman Province and determine the ideal temperature for preserving these products. Methods: After preparing nano-composite films containing silver nanoparticles (3% and 5% by weight), Mazafati dates were packed in them and stored with their control samples under four temperatures. In the second series, the films were filled with fresh pistachios and stored at four temperatures. In date samples, after 2, 7, 21 and 53 days of storing the samples were examined under the certified test of Iran Institute of Industrial Standard for Dates, which includes pH, TSS, acidity and reducing sugars tests. In pistachio samples the color values and market-friendly quality were evaluated after 1, 2, 3, 6, 7 and 8 days of storage. Results: In date samples, the pH value decreased with increasing acidity in 3 and 5 wt% of nano-silver and their control samples. In addition, in 5 wt% samples the acidity was higher than that in 3% samples, with pH being lower in the controls at almost all the intervals. Furthermore, pH values in 5% samples were higher in comparison with 3 wt% samples and controls. The amount of reducing sugars in the control samples was lower than those in 3 and 5 wt% samples. In relation to pistachio samples, the damage over time was greater in sample stored under higher temperatures. Conclusion: The maximum shelf life of the dates packaged in 5 wt% of silver nano-powder was 53 days and the best temperature to store samples was determined at 4°C. Packages containing nano-silver increased shelf life of fresh pistachios, with the best temperatures being 25°C and 0°C. PMID:26652097
Maryland English Journal, Volume 30, Numbers 1-2.
ERIC Educational Resources Information Center
Pula, Judith J., Ed.
1996-01-01
The two issues of this journal contain articles about aspects of English teaching and samples of student work. The Fall 1995 issue contains: "'I Want More Books Like It': Implementing a Reading Workshop in an Urban Classroom with At-Risk Students" (Rebecca Joseph); "Service Learning Prompt for the Maryland Writing Test" (Kathy A. Megyeri); "My…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eppich, J.D.; Hecklinger, R.S.
1995-11-01
This paper by Roger S. Hecklinger is a good contribution to the understanding of municipal solid waste combustion. The traditional test methods used on residue testing were summarized in a clear manner. Mr. Hecklinger describes sampling problems using coal and coke ash testing methods, which are similar to those experienced in testing the solid waste itself for its fuel content. The author gives several comments regarding the importance of the sampling program. This article also contains the original author`s reply to the comments and questions.
Identification of beta-lactam antibiotics in tissue samples containing unknown microbial inhibitors.
Moats, W A; Romanowski, R D; Medina, M B
1998-01-01
Antibiotic residues in animal tissues can be detected by various screening tests based on microbial inhibition. In the 7-plate assay used by the U.S. Department of Agriculture's Food Safety and Inspection Service (FSIS), penicillinase is incorporated into all but one plate to distinguish beta-lactam antibiotics from other types. However, beta-lactams such as cloxacillin and the cephalosporins are resistant to degradation by penicillinase. They may not be identified as beta-lactams by this procedure, and thus, they may be identified as unidentified microbial inhibitors (UMIs). However, these penicillinase-resistant compounds can be degraded by other beta-lactamases. The present study describes an improved screening protocol to identify beta-lactam antibiotics classified as UMIs. A multiresidue liquid chromatographic procedure based on a method for determining beta-lactams in milk was also used to identify and quantitate residues. The 2 methods were tested with 24 tissue FSIS samples classified as containing UMIs. Of these, 3 contained penicillin G, including one at a violative level, and 5 contained a metabolite of ceftiofur. The others were negative for beta-lactam antibiotics.
NASA Astrophysics Data System (ADS)
Arifan, Fahmi; Winarni, Sri; Handoyo, Gentur; Nurdiana, Asri; Nabila Rahma H, Afkar; Risdiyanti, Sri
2018-05-01
There are so many jasmine plantations without any preservation and post production in Kaliprau, Pemalang. The aims of this research are analyzing the amount of antioxidant and organoleptic-hedonic test. The measurement of antioxidant used in this research is using DPPH. The organoleptic and hedonic test on 25 respondents. Jasmines that been used on this research are the flower and the root part. Through the test, some results have been found from the jasmine tea’s sampling with the boiling time of 15 minutes and it contain antioxidant for about 55.0% and 74.84% for the jasmine root tea. Whereas for the boiling time of 30 minutes, it contained 54.00% of antioxidant for the jasmine tea and 84.00% of antioxidant in jasmine root tea. Jasmine tea and jasmine root tea contains flavonoids. Despite the large amount of antioxidant were found in jasmine tea and jasmine root tea (50-100%). There’s a decreasing of antioxidant amount found in the samples, along with the prolonged boiling time. 84% of tresponden like the scent, flavor, color and the texture of jasmine tea and jasmine root tea. These products are finally accepted by the people and have its large amount of antioxidant contain for the jasmine tea.
Cole, Laurence A; Khanlian, Sarah A
2004-05-01
False-positive hCG results can lead to erroneous diagnoses and needless chemotherapy and surgery. In the last 2 years, eight publications described cases involving false-positive hCG tests; all eight involved the AxSym test. We investigated the source of this abundance of cases and a simple fix that may be used by clinical laboratories. False-positive hCG was primarily identified by absence of hCG in urine and varying or negative hCG results in alternative tests. Seventeen false-positive serum samples in the AxSym test were evaluated undiluted and at twofold dilution with diluent containing excess goat serum or immunoglobulin. We identified 58 patients with false-positive hCG, 47 of 58 due to the Abbott AxSym total hCGbeta test (81%). Sixteen of 17 of these "false-positive" results (mean 100 mIU/ml) became undetectable when tested again after twofold dilution. A simple twofold dilution with this diluent containing excess goat serum or immunoglobulin completely protected 16 of 17 samples from patients having false-positive results. It is recommended that laboratories using this test use twofold dilution as a minimum to prevent false-positive results.
Development and Test Plans for the MSR EEV
NASA Technical Reports Server (NTRS)
Dillman, Robert; Laub, Bernard; Kellas, Sotiris; Schoenenberger, Mark
2005-01-01
The goal of the proposed Mars Sample Return mission is to bring samples from the surface of Mars back to Earth for thorough examination and analysis. The Earth Entry Vehicle is the passive entry body designed to protect the sample container from entry heating and deceleration loads during descent through the Earth s atmosphere to a recoverable location on the surface. This paper summarizes the entry vehicle design and outlines the subsystem development and testing currently planned in preparation for an entry vehicle flight test in 2010 and mission launch in 2013. Planned efforts are discussed for the areas of the thermal protection system, vehicle trajectory, aerodynamics and aerothermodynamics, impact energy absorption, structure and mechanisms, and the entry vehicle flight test.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Criteria for analyzing aluminum, copper, iron, manganese, silver and zinc samples with digestion or directly without digestion, and other analytical test procedures are contained in Technical Notes on...
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Criteria for analyzing aluminum, copper, iron, manganese, silver and zinc samples with digestion or directly without digestion, and other analytical test procedures are contained in Technical Notes on...
Code of Federal Regulations, 2011 CFR
2011-07-01
.... Criteria for analyzing aluminum, copper, iron, manganese, silver and zinc samples with digestion or directly without digestion, and other analytical test procedures are contained in Technical Notes on...
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Criteria for analyzing aluminum, copper, iron, manganese, silver and zinc samples with digestion or directly without digestion, and other analytical test procedures are contained in Technical Notes on...
Development of an optical instrument to determine the pesticide residues in vegetables
NASA Astrophysics Data System (ADS)
Qiu, Zhengjun; Fang, Hui; Li, Weimin; He, Yong
2005-12-01
An optical instrument was developed to determine the pesticide residues in vegetables based on the inhibition rate of organophosphates against acrtyl-cholinesterase (AChE). The instrument consists mainly of a solid light source with 410nm wavelength, a sampling container to store the liquid, an optical sensor to test the intensity of transmission light, a temperature sensor, and a MCU based data acquisition board. The light illuminates the liquid in the sampling container, and the absorptivity was determined by the amount of the pesticide residues in the liquid. This paper involves the design of optical testing system, the data acquisition and calibration of the optical sensor, the design of microcontroller-based electrical board. Tests show that the absorption rate is related to the pesticide residues and it can be concluded that the pesticide residues exceed the normal level when the inhibition rate is over 50 percent.
Corrosion Testing of 304L SS 3013 Inner Container and Teardrop Samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tokash, Justin Charles; Hill, Mary Ann; Lillard, Scott
The Department of Energy (DOE) 3013 Standard specifies a minimum of two containers to be used for the storage of plutonium-bearing materials containing at least 30 wt.% plutonium and uranium. Three nested containers are typically used, the outer, inner, and convenience containers, shown in Figure 1. Both the outer and inner containers are sealed with a weld while the innermost convenience container must not be sealed. Lifetime of the containers is expected to be fifty years. The containers are fabricated of austenitic stainless steels (SS) due to their high corrosion resistance. Potential failure mechanisms of the storage containers have beenmore » examined by Kolman and Lillard et al.« less
Alfredo Fernández-Niño, Julián; David Ramírez, Juan; Consuelo López, Myriam; Inés Moncada, Ligia; Reyes, Patricia; Darío Heredia, Rubén
2015-06-01
The aim of this study was to evaluate the performance of the Kato-Katz test (WHO version) with stool samples from a rural area, fixed with sodium acetate (SAF). The Kato-Katz test was used to compare unfixed samples (conventional test) with the same samples containing SAF fixative at time 0 and at 6 months. The study included stools from 154 subjects. A marginally statistically significant decrease in prevalence was estimated only for hookworm, when comparing unfixed samples versus the SAF fixed samples read at 6 months (p=0.06). A significant reduction in parasite load was found for hookworm (p<0.01) and Trichuris trichiura (p<0.01) between the unfixed and the fixed sample read at 6 months, but not for Ascaris lumbricoides (p=0.10). This research suggests that the SAF fixative solution is a good option for transporting samples for diagnosis, especially in rural areas in developing countries. Copyright © 2015 Elsevier B.V. All rights reserved.
Assessment of two thermally treated drill mud wastes for landfill containment applications.
Carignan, Marie-Pierre; Lake, Craig B; Menzies, Todd
2007-10-01
Offshore oil and gas drilling operations generate significant amounts of drill mud waste, some of which is transported onshore for subsequent thermal treatment (i.e. via thermal remediation). This treatment process results in a mineral waste by-product (referred to as thermally treated drill mud waste; TTDMW). Bentonites are originally present in many of the drill mud products and it is hypothesized that TTDMW can be utilized in landfill containment applications (i.e. cover or base liner). The objective of this paper is to examine the feasibility of this application by performing various physical and chemical tests on two TTDMW samples. It is shown that the two TTDMW samples contained relatively small amounts of clay-sized minerals although hydraulic conductivity values are found to be less than 10(-8) m/s. Organic carbon contents of the samples were approximately 2%. Mineralogy characterization of the samples confirmed varying amounts of smectite, however, peak friction angles for a TTDMW sample was greater than 36 degrees. Chemical characterization of the TTDMW samples show potential leaching of barium and small amounts of other heavy metals. Discussion is provided in the paper on suggestions to assist in overcoming regulatory issues associated with utilization of TTDMW in landfill containment applications.
Wojciechowski, Karen L; Melilli, Caterina; Barbano, David M
2014-09-01
Our objectives were to determine if mixing and sampling of a raw milk sample at 4°C for determination of total bacteria count (TBC) and if incubation at 14°C for 18h and sampling for a preliminary incubation (PI) count influenced the accuracy of subsequent fat, protein, or lactose measurement by mid-infrared (IR) analysis of milk from the same sample container due to either nonrepresentative sampling or the presence of microbial metabolites produced by microbial growth in the milk from the incubation. Milks of 4 fat levels (2.2, 3, 4, and 5%) reflected the range of fat levels encountered in producer milks. If the portion of milk removed from a cold sample was not representative, then the effect on a milk component test would likely be larger as fat content increases. Within the milks at each fat level, 3 treatments were used: (1) 20 vials of the same milk sampled for testing TBC using a BactoScan FC and then used for a milk component test; (2) 20 vials for testing TBC plus PI count followed by component test; and (3) 20 vials to run for IR component test without a prior micro sampling and testing. This was repeated in 3 different weeks using a different batch of milk each week. No large effect on the accuracy of component milk testing [IR fat B (carbon hydrogen stretch) and fat A (carbonyl stretch)] due to the cold milk sample handling and mixing procedures used for TBC was detected, confirming the fact that the physical removal of milk from the vial by the BactoScan FC (Foss Electric, Hillerød, Denmark) was a representative portion of the milk. However, the representativeness of any other sampling procedure (manual or automated) of a cold milk sample before running milk component testing on the same container of milk should be demonstrated and verified periodically as a matter of routine laboratory quality assurance. Running TBC with a BactoScan FC first and then IR milk analysis after had a minimal effect on milk component tests by IR when milk bacteria counts were within pasteurized milk ordinance limits of <100,000 cfu/mL. Running raw milk PI counts (18h of incubation at 13-14°C) with the BactoScan FC before milk component testing by IR milk analysis had an effect on component tests. The effect was largest on fat test results and would decrease the accuracy of milk payment testing on individual producer milks. The effect was most likely due to the absorption of light by bacterial metabolites resulting from microbial growth or other chemical degradation processes occurring in the milk during the PI count incubation, not by the sampling procedure of the BactoScan. The direction of the effect on component test results will vary depending on the bacteria count and the type of bacteria that grew in the milk, and this could be different in every individual producer milk sample. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Antioxidant capacity of 3D human skin EpiDerm model: effects of skin moisturizers.
Grazul-Bilska, A T; Bilski, J J; Redmer, D A; Reynolds, L P; Abdullah, K M; Abdullah, A
2009-06-01
The objective of this study was to determine the effects of skin moisturizers on total antioxidant capacity (TAC) of human skin using EpiDerm model. Three different skin moisturizers containing antioxidant ingredients (samples 1-3) or aloe vera extract were topically applied to EpiDerm units and incubated for 2 and 24 h to determine acute and longer-term effects of applied samples on TAC and glutathione peroxidase activity in medium and/or homogenized skin tissues. Total antioxidant capacity in medium and skin homogenates was enhanced (P < 0.0001) by gel containing antioxidant ingredients (sample 2) after 2 and 24 h of incubation. Total antioxidant capacity in medium was also enhanced (P < 0.001) by cream containing antioxidant ingredients (sample 3) after 24 h of incubation. Overall, TAC in medium was greater (P < 0.02) after 24 h than 2 h of incubation. Skin moisturizer cream with high antioxidant levels determined by using oxygen radical absorbance capacity testing (sample 1) and aloe vera extract did not affect TAC. Glutathione peroxidase activity was enhanced (P < 0.0001) in medium and skin homogenates by sample 2 but not by any other sample. These data demonstrate high potential of gel and cream (samples 2 and 3) containing antioxidant ingredients in enhancing antioxidant capacity of EpiDerm which will likely contribute to overall skin health. Results of this experiment will help to better understand mechanisms of effects of skin moisturizers containing antioxidant ingredients on skin function at the tissue level and to establish effective strategies for skin protection and clinical treatments of skin disorders and possibly healing wounds.
Bures, J; Kopácová, M; Vorísek, V; Bukac, J; Neumann, D; Rejchrt, S; Pozler, O; Douda, T; Zivný, P; Palicka, V
2005-01-01
13C-octanoic acid breath test (13C-OABT) is a simple, safe and non-invasive technique for measuring gastric emptying. However, the method has not been standardized yet. Aim of the study was to work up, introduce and evaluate our own method of the 13C-OABT for adults. Ten healthy volunteers entered the study (5 men, 5 women, mean age 32 years, 50 % Helicobacter pylori positive). Standard test meals (with 100 mg 13C-sodium octanoate) were used three times within 3 weeks. The same solid meal (1,178 kJ) for Tests 1 and 2 contained scrambled egg (+ 3 g oil), white bread (40 g), butter (10 g) and distilled water (200 ml). Semi-solid meal (1,020 kJ) for Test 3 contained milk pudding (200 g) and distilled water (200 ml). Duplicate breath samples were obtained before and every 15 minutes after eating the test meal during 255 minutes. Altogether 1,080 breath samples were analysed twice (isotope ratio mass spectrometry, AP2003 Analytical Precision, UK). To assess the half-life of elimination (t1/2 E), we modelled the process of elimination with the incomplete gamma-function, which has a convenient form for the empiric plotting of breath test data. Mean t1/2E was 136+/-10 minutes (Test 1), 134+/-14 (Test 2) and 123+/-16 minutes (Test 3). Clinical reproducibility of 13C-OABT in particular persons was 98.2% (18 breath samples series), 90.8 % (15 samples) and 87.1% (9 breath samples series). There was a significant correlation between Test 1 and Test 2 results (r=0.887, p<0.0001). Mean difference of duplicate breath sample analysis was 1.460 % (in 540 pairs), mean baseline one-day analysis difference was 0.0982 (99.9274% accuracy). In healthy volunteers, normal range of t1/2E is 110-160 minutes for solids and 91-155 minutes for semisolid test meal. Using our own computed mean time of intermediate metabolism of 13C-octanoic acid (76.5+/-7.5 minutes), gastric emptying half-time is 33.5-83.5 minutes for solids and 14.5-78.5 minutes for semisolid test meal in healthy volunteers. The 13C-OABT is accurate non-invasive method for gastric emptying measurement.
46 CFR 164.009-15 - Test procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
... submitted for approval, except fiberglass and other materials that melt at 750° ±10 °C. Paragraph (l) of this section contains test procedures for fiberglass and other materials that melt at 750° ±10 °C. (b... properties of the sample submitted for testing. The dimensions of each specimen are as follows: diameter: 45...
46 CFR 164.009-15 - Test procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
... submitted for approval, except fiberglass and other materials that melt at 750° ±10 °C. Paragraph (l) of this section contains test procedures for fiberglass and other materials that melt at 750° ±10 °C. (b... properties of the sample submitted for testing. The dimensions of each specimen are as follows: diameter: 45...
Screening for toxic phorbol esters in jerky pet treat products using LC-MS.
Nishshanka, Upul; Jayasuriya, Hiranthi; Chattopadhaya, Chaitali; Kijak, Philip J; Chu, Pak-Sin; Reimschuessel, Renate; Tkachenko, Andriy; Ceric, Olgica; De Alwis, Hemakanthi G
2016-05-01
Since 2007, the U.S. FDA's Center for Veterinary Medicine (CVM) has been investigating reports of pets becoming ill after consuming jerky pet treats. Jerky used in pet treats contains glycerin, which can be made from vegetable oil or as a byproduct of biodiesel production. Because some biodiesel is produced using oil from Jatropha curcas, a plant that contains toxic compounds including phorbol esters, CVM developed a liquid chromatography-mass spectrometry (LC-MS) screening method to evaluate investigational jerky samples for the presence of these toxins. Results indicated that the samples analyzed with the new method did not contain Jatropha toxins at or above the lowest concentration tested. Published by Elsevier B.V.
New Glass Serves as Window to Cutting-edge Lasers
NASA Technical Reports Server (NTRS)
2004-01-01
Since 1997, Marshall Space Flight Center s Electrostatic Levitator (ESL) facility has been used to study the characteristics of new metals, ceramics, and glass compounds - in both their hot molten states and as they are cooled to form solid materials. The ESL provides a unique way to test such substances without having to make contact with a container or crucible that would contaminate the sample. Simply put, objects analyzed in the levitator's chamber float in mid-air with no visible means of support or containment, suspended only by static electricity. While a sample object is levitated, a laser beam heats it until it melts so that scientists can measure its physical properties without interference from a container.
Reichel, Mirja; Heisig, Peter; Kampf, Günter
2008-12-02
Effective neutralization of active agents is essential to obtain valid efficacy results, especially when non-volatile active agents like chlorhexidine digluconate (CHG) are tested. The aim of this study was to determine an effective and non-toxic neutralizing mixture for a propan-1-ol solution containing 2% CHG. Experiments were carried out according to ASTM E 1054-02. The neutralization capacity was tested separately with five challenge microorganisms in suspension, and with a rayon swab carrier. Either 0.5 mL of the antiseptic solution (suspension test) or a saturated swab with the antiseptic solution (carrier test) was added to tryptic soy broth containing neutralizing agents. After the samples were mixed, aliquots were spread immediately and after 3 h of storage at 2 - 8 degrees C onto tryptic soy agar containing a neutralizing mixture. The neutralizer was, however, not consistently effective in the suspension test. Immediate spread yielded a valid neutralization with Staphylococcus aureus, Staphylococcus epidermidis and Corynebacterium jeikeium but not with Micrococcus luteus (p < 0.001) and Candida albicans (p < 0.001). A 3-h storage period of the neutralized active agents in suspension resulted in significant carry-over activity of CHG in addition against Staphylococcus epidermidis (p < 0.001) and Corynebacterium jeikeium (p = 0.044). In the carrier test, the neutralizing mixture was found to be effective and non toxic to all challenge microorganisms when spread immediately. However, after 3 h storage of the neutralized active agents significant carry-over activity of CHG against Micrococcus luteus (p = 0.004; Tukey HSD) was observed. Without effective neutralization in the sampling fluid, non-volatile active ingredients will continue to reduce the number of surviving microorganisms after antiseptic treatment even if the sampling fluid is kept cold straight after testing. This can result in false-positive antiseptic efficacy data. Attention should be paid during the neutralization validation process to the amount of antiseptic solution, the storage time and to the choice of appropriate and sensitive microorganisms.
Sample diversity and premise typicality in inductive reasoning: evidence for developmental change.
Rhodes, Marjorie; Brickman, Daniel; Gelman, Susan A
2008-08-01
Evaluating whether a limited sample of evidence provides a good basis for induction is a critical cognitive task. We hypothesized that whereas adults evaluate the inductive strength of samples containing multiple pieces of evidence by attending to the relations among the exemplars (e.g., sample diversity), six-year-olds would attend to the degree to which each individual exemplar in a sample independently appears informative (e.g., premise typicality). To test these hypotheses, participants were asked to select between diverse and non-diverse samples to help them learn about basic-level animal categories. Across various between-subject conditions (N=133), we varied the typicality present in the diverse and non-diverse samples. We found that adults reliably selected to examine diverse over non-diverse samples, regardless of exemplar typicality, six-year-olds preferred to examine samples containing typical exemplars, regardless of sample diversity, and nine-year-olds were somewhat in the midst of this developmental transition.
9 CFR 113.300 - General requirements for live virus vaccines.
Code of Federal Regulations, 2010 CFR
2010-01-01
... control cells shall remain free of such fluorescence. (2) Serum neutralization test. The serum... fungi in accordance with the test provided in § 113.27. (2) Mycoplasma. Final container samples of... inoculated cells and uninoculated control cells. Cells shall be stained with fluorochrome conjugated specific...
Code of Federal Regulations, 2010 CFR
2010-04-01
... chapter, and any distribution of an animal drug or animal feed bearing or containing an animal drug for..., and animal facilities used for the production or control testing of licensed biologicals, and... definition of drugs in section 201(g) of the act. The term includes manipulation, sampling, testing, or...
Code of Federal Regulations, 2012 CFR
2012-04-01
... chapter, and any distribution of an animal drug or animal feed bearing or containing an animal drug for..., and animal facilities used for the production or control testing of licensed biologicals, and... definition of drugs in section 201(g) of the act. The term includes manipulation, sampling, testing, or...
Code of Federal Regulations, 2013 CFR
2013-04-01
... chapter, and any distribution of an animal drug or animal feed bearing or containing an animal drug for..., and animal facilities used for the production or control testing of licensed biologicals, and... definition of drugs in section 201(g) of the act. The term includes manipulation, sampling, testing, or...
Code of Federal Regulations, 2014 CFR
2014-04-01
... chapter, and any distribution of an animal drug or animal feed bearing or containing an animal drug for..., and animal facilities used for the production or control testing of licensed biologicals, and... definition of drugs in section 201(g) of the act. The term includes manipulation, sampling, testing, or...
Code of Federal Regulations, 2011 CFR
2011-04-01
... chapter, and any distribution of an animal drug or animal feed bearing or containing an animal drug for..., and animal facilities used for the production or control testing of licensed biologicals, and... definition of drugs in section 201(g) of the act. The term includes manipulation, sampling, testing, or...
1998-11-01
Avoid contact with samples. Be aware of broken containers, corrosives, irritants, biohazards, flammability, pyrophoricity , reactivity, radioactivity...Revision RO 9/23/97 Page 3 NOj-N by Flow Injection Analysis 6.2.2.2 Low results may be obtained for samples that contain high concentrations of iron ...however, for analytes such as iron that may be found at high concentration, a more appropriate test would be to use a concentration near the upper
Reuse of steel slag in bituminous paving mixtures.
Sorlini, Sabrina; Sanzeni, Alex; Rondi, Luca
2012-03-30
This paper presents a comprehensive study to evaluate the mechanical properties and environmental suitability of electric arc furnace (EAF) steel slag in bituminous paving mixtures. A variety of tests were executed on samples of EAF slag to characterize the physical, geometrical, mechanical and chemical properties as required by UNI EN specifications, focusing additionally on the volumetric expansion associated with hydration of free CaO and MgO. Five bituminous mixtures of aggregates for flexible road pavement were designed containing up to 40% of EAF slag and were tested to determine Marshall stability and indirect tensile strength. The leaching behaviour of slag samples and bituminous mixtures was evaluated according to the UNI EN leaching test. The tested slag showed satisfactory physical and mechanical properties and a release of pollutants generally below the limits set by the Italian code. Tests on volume stability of fresh materials confirmed that a period of 2-3 months is necessary to reduce effects of oxides hydration. The results of tests performed on bituminous mixtures with EAF slag were comparable with the performance of mixtures containing natural aggregates and the leaching tests provided satisfactory results. Copyright © 2012 Elsevier B.V. All rights reserved.
Mars Sample Handling Protocol Workshop Series: Workshop 2
NASA Technical Reports Server (NTRS)
Rummel, John D. (Editor); Acevedo, Sara E. (Editor); Kovacs, Gregory T. A. (Editor); Race, Margaret S. (Editor); DeVincenzi, Donald L. (Technical Monitor)
2001-01-01
Numerous NASA reports and studies have identified Planetary Protection (PP) as an important part of any Mars sample return mission. The mission architecture, hardware, on-board experiments, and related activities must be designed in ways that prevent both forward- and back-contamination and also ensure maximal return of scientific information. A key element of any PP effort for sample return missions is the development of guidelines for containment and analysis of returned sample(s). As part of that effort, NASA and the Space Studies Board (SSB) of the National Research Council (NRC) have each assembled experts from a wide range of scientific fields to identify and discuss issues pertinent to sample return. In 1997, the SSB released its report on recommendations for handling and testing of returned Mars samples. In particular, the NRC recommended that: a) samples returned from Mars by spacecraft should be contained and treated as potentially hazardous until proven otherwise, and b) rigorous physical, chemical, and biological analyses [should] confirm that there is no indication of the presence of any exogenous biological entity. Also in 1997, a Mars Sample Quarantine Protocol workshop was convened at NASA Ames Research Center to deal with three specific aspects of the initial handling of a returned Mars sample: 1) biocontainment, to prevent 'uncontrolled release' of sample material into the terrestrial environment; 2) life detection, to examine the sample for evidence of organisms; and 3) biohazard testing, to determine if the sample poses any threat to terrestrial life forms and the Earth's biosphere. In 1999, a study by NASA's Mars Sample Handling and Requirements Panel (MSHARP) addressed three other specific areas in anticipation of returning samples from Mars: 1) sample collection and transport back to Earth; 2) certification of the samples as non-hazardous; and 3) sample receiving, curation, and distribution. To further refine the requirements for sample hazard testing and the criteria for subsequent release of sample materials from quarantine, the NASA Planetary Protection Officer convened an additional series of workshops beginning in March 2000. The overall objective of these workshops was to develop comprehensive protocols to assess whether the returned materials contain any biological hazards, and to safeguard the purity of the samples from possible terrestrial contamination. This document is the report of the second Workshop in the Series. The information herein will ultimately be integrated into a final document reporting the proceedings of the entire Workshop Series along with additional information and recommendations.
Goryacheva, I Yu; De Saeger, S; Lobeau, M; Eremin, S A; Barna-Vetró, I; Van Peteghem, C
2006-09-01
An approach for ochratoxin A (OTA) fast cost-effective screening based on clean-up tandem immunoassay columns was developed and optimized for OTA detection with a cut-off level of 10 microg kg(-1) in spices. Two procedures were tested and applied for OTA detection. Column with bottom detection immunolayer was optimized for OTA determination in Capsicum ssp. spices. A modified clean-up tandem immunoassay procedure with top detection immunolayer was successfully applied for all tested spices. Its main advantages were decreasing of the number of analysis steps and quantity of antibody and also minimizing of matrix effects. The total duration of the extraction and analysis was about 40 min for six samples. Chilli, red pepper, pili-pili, cayenne, paprika, nutmeg, ginger, white pepper and black pepper samples were analyzed for OTA contamination by the proposed clean-up tandem immunoassay procedures. Clean-up tandem immunoassay results were confirmed by HPLC-MS/MS with immunoaffinity column clean-up. Among 17 tested Capsicum ssp. spices, 6 samples (35%) contained OTA in a concentration exceeding the 10 microg kg(-1) limit discussed by the European Commission. All tested nutmeg (n=8), ginger (n=5), white pepper (n=7) and black pepper (n=6) samples did not contain OTA above this action level.
Identification of fecal contamination sources in water using host-associated markers.
Krentz, Corinne A; Prystajecky, Natalie; Isaac-Renton, Judith
2013-03-01
In British Columbia, Canada, drinking water is tested for total coliforms and Escherichia coli, but there is currently no routine follow-up testing to investigate fecal contamination sources in samples that test positive for indicator bacteria. Reliable microbial source tracking (MST) tools to rapidly test water samples for multiple fecal contamination markers simultaneously are currently lacking. The objectives of this study were (i) to develop a qualitative MST tool to identify fecal contamination from different host groups, and (ii) to evaluate the MST tool using water samples with evidence of fecal contamination. Singleplex and multiplex polymerase chain reaction (PCR) were used to test (i) water from polluted sites and (ii) raw and drinking water samples for presence of bacterial genetic markers associated with feces from humans, cattle, seagulls, pigs, chickens, and geese. The multiplex MST assay correctly identified suspected contamination sources in contaminated waterways, demonstrating that this test may have utility for heavily contaminated sites. Most raw and drinking water samples analyzed using singleplex PCR contained at least one host-associated marker. Singleplex PCR was capable of detecting host-associated markers in small sample volumes and is therefore a promising tool to further analyze water samples submitted for routine testing and provide information useful for water quality management.
ERIC Educational Resources Information Center
Abed, Eman Rasmi; Al-Absi, Mohammad Mustafa; Abu shindi, Yousef Abdelqader
2016-01-01
The purpose of the present study is developing a test to measure the numerical ability for students of education. The sample of the study consisted of (504) students from 8 universities in Jordan. The final draft of the test contains 45 items distributed among 5 dimensions. The results revealed that acceptable psychometric properties of the test;…
Maenthaisong, Ratree; Viyoch, Jarupa; Chaiyakunapruk, Nathorn; Warnnissorn, Prateep
2007-09-01
Cleansing lotion containing extract of tamarind fruit pulp was developed to provide skin a lighter effect. Skin irritation may occur due to keratolytic effect of alpha-hydroxyl acids (AHA) in the tamarind fruit pulp extract. To assess the cumulative irritation effect of cleansing lotion containing tamarind fruit extract with 2% (w/w) tartaric acid on human skin compared with placebo product and de-ionized water. The study design was a single-blinded, randomized side of arm, and controlled study. Three samples, including test product, placebo product, and de-ionized water, were repeatedly applied on the inner forearm of 15 healthy females (aged 28.3 +/- 3.1 years) for 30 min daily for 5 days under semi-occlusive patch. Skin irritation was measured by using visual scoring and instruments such as Tewameter and Mexameter. All measurements were done before application of samples every day from day 1 until day 5. Final measurements were done after the last application for 3 days (day 8). The results obtained from the visual scoring scale indicated no irritation signs and symptoms of test product. Mean differences of transepidermal water loss and erythema values between test product and de-ionized water and between test and placebo products were not statistically significant (P > 0.05). These findings indicate a preliminary safety evidence of our developed cleansing lotion containing the natural AHAs and can be used as cumulative evidence for supporting the future home use study of this product in human.
Development and Testing of Harpoon-Based Approaches for Collecting Comet Samples (Video Supplement)
NASA Technical Reports Server (NTRS)
Purves, Lloyd (Compiler); Nuth, Joseph (Compiler); Amatucci, Edward (Compiler); Wegel, Donald; Smith, Walter; Leary, James; Kee, Lake; Hill, Stuart; Grebenstein, Markus; Voelk, Stefan;
2017-01-01
This video supplement contains a set of videos created during the approximately 10-year-long course of developing and testing the Goddard Space Flight Center (GSFC) harpoon-based approach for collecting comet samples. The purpose of the videos is to illustrate various design concepts used in this method of acquiring samples of comet material, the testing used to verify the concepts, and the evolution of designs and testing. To play the videos this PDF needs to be opened in the freeware Adobe Reader. They do not seem to play while within a browser. While this supplement can be used as a stand-alone document, it is intended to augment its parent document of the same title, Development and Testing of Harpoon-Based Approaches for Collecting Comet Samples (NASA/CR-2017-219018; this document is accessible from the website: https://ssed.gsfc.nasa.gov/harpoon/SAS_Paper-V1.pdf). The parent document, which only contains text and figures, describes the overall development and testing effort and contains references to each of the videos in this supplement. Thus, the videos are primarily intended to augment the information provided by the text and figures in the parent document. This approach was followed to allow the file size of the parent document to remain small enough to facilitate downloading and storage. Some of the videos were created by other organizations, Johns Hopkins University Applied Physics Laboratory (JHU APL) and the German Aerospace Center called, the Deutsches Zentrum für Luft- und Raumfahrt (DLR), who are partnering with GSFC on developing this technology. Each video is accompanied by text that provides a summary description of its nature and purpose, as well as the identity of the authors. All videos have been edited to only show key parts of the testing. Although not all videos have sound, the sound has been retained in those that have it. Also, each video has been given one or more title screens to clarify what is going in different phases of the video.
Hooten, Russell L.; Carr, R. Scott
1998-01-01
An acute (96 h) pore-water toxicity test protocol using germination and growth of Ulva fasciatazoospores as endpoints was developed to test the toxicity of marine and estuarine sediment pore-water samples. Tests with an organic toxicant (sodium dodecyl sulfate; SDS), three metals (Cd, Cu, and Zn), and ammonia (NH3) were conducted to determine zoospore sensitivity. Zoospore germination and gametophyte growth were as sensitive to SDS as sea urchin (Arbacia punctulata) fertilization and embryological development. Zoospore sensitivity to metals was greater than or comparable to that of adult macroalgae. Zoospores were less sensitive to NH3than were other commonly used toxicity test organisms. Test results using this algal assay with sediment pore-water samples with high NH3 concentrations were compared with results from sea urchin fertilization and embryological development tests for the same samples. Ulva fasciatazoospore germination was not affected by samples with high NH3 concentrations that were toxic in both sea urchin tests. Zoospore tolerance of NH3 and sensitivity to other contaminants indicate that their response may be useful in toxicity identification evaluation studies with pore-water samples that contain high concentrations of unionized NH3.
Plasma Accelerator and Energy Conversion Research
1982-10-29
performance tests have been accomplished. A self-contained recirculating AMTEC device with a thermal to electric conversion efficiency of 19% has been...combined efficiency . These two match up particularly well, because thermionic conversion is a high temperature technique, whereas AMTEC is limited to...EXPERIENTAL: Samples: The samples were prepared with a high rate DC magnetron sputtering apparatus ( SFI model 1 ). The sample set consisted of four
Engineering scale demonstration of a prospective Cast Stone process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cozzi, A.; Fowley, M.; Hansen, E.
2014-09-30
This report documents an engineering-scale demonstration with non-radioactive simulants that was performed at SRNL using the Scaled Continuous Processing Facility (SCPF) to fill an 8.5 ft container with simulated Cast Stone grout. The Cast Stone formulation was chosen from the previous screening tests. Legacy salt solution from previous Hanford salt waste testing was adjusted to correspond to the average composition generated from the Hanford Tank Waste Operation Simulator (HTWOS). The dry blend materials, ordinary portland cement (OPC), Class F fly ash, and ground granulated blast furnace slag (GGBFS or BFS), were obtained from Lafarge North America in Pasco, WA. Overmore » three days, the SCPF was used to fill a 1600 gallon container, staged outside the facility, with simulated Cast Stone grout. The container, staged outside the building approximately 60 ft from the SCPF, was instrumented with x-, y-, and z-axis thermocouples to monitor curing temperature. The container was also fitted with two formed core sampling vials. For the operation, the targeted grout production rate was 1.5 gpm. This required a salt solution flow rate of approximately 1 gpm and a premix feed rate of approximately 580 lb/h. During the final day of operation, the dry feed rate was increased to evaluate the ability of the system to handle increased throughput. Although non-steady state operational periods created free surface liquids, no bleed water was observed either before or after operations. The final surface slope at a fill height of 39.5 inches was 1-1.5 inches across the 8.5 foot diameter container, highest at the final fill point and lowest diametrically opposed to the fill point. During processing, grout was collected in cylindrical containers from both the mixer discharge and the discharge into the container. These samples were stored in a humid environment either in a closed box proximal to the container or inside the laboratory. Additional samples collected at these sampling points were analyzed for rheological properties and density. Both the rheological properties (plastic viscosity and yield strength) and density were consistent with previous and later SCPF runs.« less
Tang, Hongmao; Beg, Khaliq R.; Al-Otaiba, Yousef
2006-01-01
Kuwait experiences desert climatic weather. Due to the extreme hot and dry conditions in this country, some analytical phenomena have been discovered. Therefore, a systematic study of sampling and analyzing volatile organic compounds in air by using GC-MS with a cryogenic trap is reported in this paper. This study included comparisons of using different sample containers such as Tedlar bags and SUMMA canisters, and different cryogenic freezing-out air volumes in the trap. Calibration curves for different compounds and improvement of replicated analysis results were also reported here. The study found that using different sample containers produced different results. Analysis of ambient air samples collected in Tedlar bags obtained several volatile organic compounds with large concentrations compared to using SUMMA canisters. Therefore, to choose a sample container properly is a key element for successfully completing a project. Because GC-MS with a cryogenic trap often generates replicated results with poor agreement, an internal standard added to gas standards and air samples by using a gas syringe was tested. The study results proved that it helped to improve the replicated results. PMID:16699723
Tang, Hongmao; Beg, Khaliq R; Al-Otaiba, Yousef
2006-05-12
Kuwait experiences desert climatic weather. Due to the extreme hot and dry conditions in this country, some analytical phenomena have been discovered. Therefore, a systematic study of sampling and analyzing volatile organic compounds in air by using GC-MS with a cryogenic trap is reported in this paper. This study included comparisons of using different sample containers such as Tedlar bags and SUMMA canisters, and different cryogenic freezing-out air volumes in the trap. Calibration curves for different compounds and improvement of replicated analysis results were also reported here. The study found that using different sample containers produced different results. Analysis of ambient air samples collected in Tedlar bags obtained several volatile organic compounds with large concentrations compared to using SUMMA canisters. Therefore, to choose a sample container properly is a key element for successfully completing a project. Because GC-MS with a cryogenic trap often generates replicated results with poor agreement, an internal standard added to gas standards and air samples by using a gas syringe was tested. The study results proved that it helped to improve the replicated results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beckley, D.A.; Stites, J. Jr.
The objective was to characterize several lots of materials used for carbon/carbon and carbon/phenol product manufacture. Volume one is organized into testing categories based on raw material of product form. Each category contains a discussion of the sampling plan, comments and observations on each test method utilized, and a summary of the results obtained each category.
46 CFR 160.026-6 - Sampling, inspection, and tests of production lots.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Bacteriological limits and salt content MIL-W-15117 and U.S. Public Health “Drinking Water Standards.” (e) Lot..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Water, Emergency Drinking (In... lots. (a) General. Containers of emergency drinking water must be tested in accordance with the...
46 CFR 160.026-6 - Sampling, inspection, and tests of production lots.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Bacteriological limits and salt content MIL-W-15117 and U.S. Public Health “Drinking Water Standards.” (e) Lot..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Water, Emergency Drinking (In... lots. (a) General. Containers of emergency drinking water must be tested in accordance with the...
46 CFR 160.026-6 - Sampling, inspection, and tests of production lots.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Bacteriological limits and salt content MIL-W-15117 and U.S. Public Health “Drinking Water Standards.” (e) Lot..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Water, Emergency Drinking (In... lots. (a) General. Containers of emergency drinking water must be tested in accordance with the...
46 CFR 160.026-6 - Sampling, inspection, and tests of production lots.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Bacteriological limits and salt content MIL-W-15117 and U.S. Public Health “Drinking Water Standards.” (e) Lot..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Water, Emergency Drinking (In... lots. (a) General. Containers of emergency drinking water must be tested in accordance with the...
46 CFR 160.026-6 - Sampling, inspection, and tests of production lots.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Bacteriological limits and salt content MIL-W-15117 and U.S. Public Health “Drinking Water Standards.” (e) Lot..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Water, Emergency Drinking (In... lots. (a) General. Containers of emergency drinking water must be tested in accordance with the...
ERIC Educational Resources Information Center
Instructional Objectives Exchange, Los Angeles, CA.
Ninety objectives and related test items for use in grades 7 through 12 are presented. Each sample contains an objective, test items, and criteria for judging the adequacy of the response. Objectives are organized into the following categories: (1) property of metals; (2) operations and functions; (3) cutting and shearing; (4) filing; (5) cutting…
9 CFR 113.105 - Leptospira Hardjo Bacterin.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Leptospira Hardjo Bacterin. 113.105 Section 113.105 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF... unsatisfactory by any prescribed test shall not be released. (a) Purity test. Final container samples of...
Evaluation of standardized sample collection, packaging, and ...
Journal Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures.
McHugh, John B.; Miller, W. Roger
1989-01-01
In the spring of 1984, a hydrogeochemical survey was conducted in the Kingdom of Saudi Arabia to test ground water as a sampling medium in exploration for mineral deposits. Eighty-one water samples (mostly from wells) were collected. The samples were analysed for the presence and concentration of major cations and anions, as well as a suite of trace elements. Most of the water samples contained high concentrations of dissolved salts. The majority of the samples showed no significant amounts of the trace elements. A few well-water samples contained moderately anomalous concentrations of zinc, molybdenum, and uranium. These anomalies could be due to salinity effects, contamination, or the proximity of mineral sources. This survey has established some baseline water-chemistry data, especially for the trace metals, which to date have not been reported in ground water in the Kingdom of Saudi Arabia.
Nikolelis, Dimitrios P; Drivelos, Dimitrios A; Simantiraki, Maria G; Koinis, Spyros
2004-04-15
The present technique describes a simple, sensitive spot test for the rapid one-shot detection of dopamine in human urine using lipid films with incorporated resorcin[4]arene receptor that are synthesized by a chemical reaction with a methacrylate polymer on a glass fiber filter. The lipid films without the receptor provided fluorescence under a UV lamp. The use of the receptor in these films quenched this fluorescence, and the color became similar to that of the filters without the lipid films. A drop of dopamine or urine containing this stimulant provided a "switching on" of the fluorescence, which allows the rapid detection of this stimulant in human urine at 10(-8) M concentrations. The novelty of the present work is that it opens new routes in the field of biosensing, i.e., development of sensitive, rapid, and simple methods for detecting species based on the fluorescence of the lipid membranes on a polymer film, and provides a spot test technique for the rapid detection of dopamine. The effect of potent interferences including a wide range of compounds usually found in human urine (i.e., ascorbic aid, glucose, leucine, glycine, tartrate, citrate, bicarbonate, and caffeine) was examined using an aqueous buffered solution that contained the potent interference and dopamine at two lower concentration levels (i.e., 3 x 10(-8)-10(-8) M). The effect of proteins and lipids was also investigated at these two lower dopamine concentration levels in aqueous buffered solution. The results showed no interferences from all these constituents at concentrations usually found in human urine samples; for example, albumin up to 3.22 g/L concentration levels did not provide any interference (i.e., no fluorescence). A drop of urine containing this stimulant provided similar results, i.e., a "switching on" of the fluorescence that allows a technique for the rapid detection of this stimulant in human urine at 10(-8) M concentrations. The technique is not based on a calibration graph but is a semiquantitative method for the detection of dopamine in real samples of urine that can be complimentary to HPLC methods. The difference in color between the samples containing dopamine at concentration levels of 10(-8)-10(-7) M can be easily distinguished by naked eye and a digital camera. An increase of dopamine concentration from 10(-8) to 10(-7) M makes the color more blue whereas the color of the filters remains purple in the blank test (i.e., addition of a urine sample without dopamine or dopamine at concentration levels of 10(-9) M to the filters that contain the lipid membranes with incorporated receptor). The reproducibility of the method was checked in approximately 100 samples, and all of them were found to provide similar results. Note that it was also found that the colors remain stable in the samples containing dopamine for periods of more than two months.
40 CFR 141.40 - Monitoring requirements for unregulated contaminants.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Contaminant List, in paragraph (a)(3) of this section. EPA will provide sample containers, provide pre-paid... Testing to be Sampled After Notice of Analytical Methods Availability] 1—Contaminant 2—CAS registry number... Records Administration (NARA). For information on availability of this material at NARA, call 202-741-6030...
High concentrations of furan fatty acids in organic butter samples from the German market.
Wendlinger, Christine; Vetter, Walter
2014-08-27
Furan fatty acids (F-acids) are valuable antioxidants containing a furan moiety in the central part of the molecule. They occur in the lipids of different foodstuffs and plants, with grass being the main source for their presence in milk fat and butter. Because cows from organic farming receive higher portions of grass-based feed, it was tested whether organic butter samples (n = 26) contain more F-acids than conventional ones (n = 25) in Germany. For this purpose, samples were melted, and the lipid phase was separated and transesterified into methyl esters, which were enriched using silver ion chromatography and analyzed by GC-EI/MS in the selected ion monitoring (SIM) mode. Levels of F-acids in butter were higher in summer than in winter, and in both seasons, organic samples contained significantly higher levels of F-acids than conventional ones (one-way ANOVA: p < 0.001). Furthermore, the daily intake of F-acids via milk fat and other foodstuffs was calculated.
Mitchell, J M; Yee, A J; McNab, W B; Griffiths, M W; McEwen, S A
1999-01-01
LacTek tests are competitive enzyme-linked immunosorbent assays intended for rapid detection of antimicrobial residues in bovine milk. In this study, the LacTek test protocol was modified for use with extracts of bovine tissue to detect beta-lactam, tetracycline, and sulfamethazine residues. Test performance characteristics--precision, accuracy, ruggedness, practicability, and analytical specificity and sensitivity--were investigated. Results suggest that LacTek tests can be easily adapted to detect antimicrobial residues in extracts of lean ground beef. However, positive samples may not contain residues at violative concentrations (i.e., Canadian maximum residue limits), and therefore, additional analysis would be required for final confirmation and quantitation (e.g., chromatography).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milstein, O.; Gersonde, R.; Huttermann, A.
1992-10-01
White rot basidiomycetes were able to biodegrade styrene (1-phenylethene) graft copolymers of lignin containing different proportions of lignin and polystyrene (poly(1-phenylethylene)). The biodegradation tests were run on lignin-styrene copolymerization products which contained 10.3, 32.2, and 50.4{percent} (wt/wt) lignin. The polymer samples were incubated with the white rot fungi Pleurotus ostreatus, Phanerochaete chrysosporium, and Trametes versicolor and the brown rot fungus Gloeophyllum trabeum. White rot fungi degraded the plastic samples at a rate which increased with increasing lignin content in the copolymer sample. Both polystyrene and lignin components of the copolymer were readily degraded. Polystyrene pellets were not degradable in thesemore » tests. Degradation was verified for both incubated and control samples by weight loss, quantitative UV spectrophotometric analysis of both lignin and styrene residues, scanning electron microscopy of the plastic surface, and the presence of enzymes active in degradation during incubation. Brown rot fungus did not affect any of the plastics. White rot fungi produced and secreted oxidative enzymes associated with lignin degradation in liquid media during incubation with lignin-polystyrene copolymer.« less
PlanetVac: Sample Return with a Puff of Gas
NASA Astrophysics Data System (ADS)
Zacny, K.; Mueller, R.; Betts, B. H.
2014-12-01
PlanetVac is a regolith sample acquisition mission concept that uses compressed gas to blow material from the surface up a pneumatic tube and directly into a sample return container. The PlanetVac sampling device is built into the lander legs to eliminate cost and complexity associated with robotic arms and scoops. The pneumatic system can effectively capture fine and coarse regolith, including small pebbles. It is well suited for landed missions to Mars, asteroids, or the Moon. Because of the low pressures on all those bodies, the technique is extremely efficient. If losses are kept to minimum, 1 gram of compressed gas could efficiently lift 6000 grams of soil. To demonstrate this approach, the PlanetVac lander with four legs and two sampling tubes has been designed, integrated, and tested. Vacuum chamber testing was performed using two well-known planetary regolith simulants: Mars Mojave Simulant (MMS) and lunar regolith simulant JSC-1A. One of the two sampling systems was connected to a mockup of an earth return rocket while the second sampling system was connected to a lander deck mounted instrument (clear box for easy viewing). The tests included a drop from a height of approximately 50 cm onto the bed of regolith, deployment of sampling tubes into the regolith, pneumatic acquisition of sample into an instrument (sample container) and the rocket, and the launch of the rocket. The demonstration has been successful and can be viewed here: https://www.youtube.com/watch?v=DjJXvtQk6no. In most of the tests, 20 grams or more of sample was delivered to the 'instrument' and approximately 5 grams of regolith was delivered into a sampling chamber within the rocket. The gas lifting efficiency was calculated to be approximately 1000:1; that is 1 gram of gas lofted 1000 grams of regolith. Efficiencies in lower gravity environments are expected to be much higher. This successful, simple and lightweight sample capture demonstration paves the way to using such sampling system on either NASA or commercial landers to the Moon, Asteroids, comets, or Mars.
Results of an international drug testing service for cryptomarket users.
Caudevilla, Fernando; Ventura, Mireia; Fornís, Iván; Barratt, Monica J; Vidal, Claudio; Lladanosa, Cristina Gil; Quintana, Pol; Muñoz, Ana; Calzada, Nuria
2016-09-01
User surveys indicate that expectations of higher drug purity are a key reason for cryptomarket use. In 2014-2015, Spain's NGO Energy Control conducted a 1-year pilot project to provide a testing service to cryptomarket drug users using the Transnational European Drug Information (TEDI) guidelines. In this paper, we present content and purity data from the trial. 219 samples were analyzed by gas chromatography associated with mass spectrometry (GC/MS). Users were asked to report what substance they allegedly purchased. 40 different advertised substances were reported, although 77.6% were common recreational drugs (cocaine, MDMA, amphetamines, LSD, ketamine, cannabis). In 200 samples (91.3%), the main result of analysis matched the advertised substance. Where the advertised compound was detected, purity levels (m±SD) were: cocaine 71.6±19.4%; MDMA (crystal) 88.3±1.4%; MDMA (pills) 133.3±38.4mg; Amphetamine (speed) 51.3±33.9%; LSD 123.6±40.5μg; Cannabis resin THC: 16.5±7.5% CBD: 3.4±1.5%; Ketamine 71.3±38.4%. 39.8% of cocaine samples contained the adulterant levamisole (11.6±8%). No adulterants were found in MDMA and LSD samples. The largest collection of test results from drug samples delivered from cryptomarkets are reported in this study. Most substances contained the advertised ingredient and most samples were of high purity. The representativeness of these results is unknown. Copyright © 2016 Elsevier B.V. All rights reserved.
Ulca, P; Öztürk, Y; Senyuva, H Z
2011-01-01
Surveys were carried out between 2007 and 2010 to determine the total levels of sulfites in 1245 samples of wines, dried apricots, dried vegetables, nuts, juices and purees, frozen foods and cereals containing dried fruit supplied by food inspectors and by food producers for testing or for export certification. Sulfite analysis of wine was carried out using the Ripper method with an LOQ of 5 mg l(-1) and for dried and other foods the Monier-Williams distillation procedure was employed with an LOQ of 10 mg kg(-1). In the survey all wines contained measurable sulfites, but with the exception of one sample of white wine they were otherwise below Turkish Food Codex limits of 160 mg kg(-1) for red wine, 210 mg kg(-1) to white wine and 235 mg kg(-1) for sparkling wine. None of the cereal products, frozen foods, juices or purees contained sulfites above 10 mg kg(-1). However, all dried apricot samples contained significant levels of sulfite with around 40% having levels exceeding the Turkish limit of 2000 mg kg(-1). Significant levels of sulfite were found in other samples of dried fruit with even a fruit and nut bar containing 1395 mg kg(-1) of sulfite, suggesting the dried fruit ingredients contained levels above regulatory limits.
Analysis of on-line clinical laboratory manuals and practical recommendations.
Beckwith, Bruce; Schwartz, Robert; Pantanowitz, Liron
2004-04-01
On-line clinical laboratory manuals are a valuable resource for medical professionals. To our knowledge, no recommendations currently exist for their content or design. To analyze publicly accessible on-line clinical laboratory manuals and to propose guidelines for their content. We conducted an Internet search for clinical laboratory manuals written in English with individual test listings. Four individual test listings in each manual were evaluated for 16 data elements, including sample requirements, test methodology, units of measure, reference range, and critical values. Web sites were also evaluated for supplementary information and search functions. We identified 48 on-line laboratory manuals, including 24 academic or community hospital laboratories and 24 commercial or reference laboratories. All manuals had search engines and/or test indices. No single manual contained all 16 data elements evaluated. An average of 8.9 (56%) elements were present (range, 4-14). Basic sample requirements (specimen and volume needed) were the elements most commonly present (98% of manuals). The frequency of the remaining data elements varied from 10% to 90%. On-line clinical laboratory manuals originate from both hospital and commercial laboratories. While most manuals were user-friendly and contained adequate specimen-collection information, other important elements, such as reference ranges, were frequently absent. To ensure that clinical laboratory manuals are of maximal utility, we propose the following 13 data elements be included in individual test listings: test name, synonyms, test description, test methodology, sample requirements, volume requirements, collection guidelines, transport guidelines, units of measure, reference range, critical values, test availability, and date of latest revision.
Bruins, Marjan J.; Bloembergen, Peter; Ruijs, Gijs J. H. M.; Wolfhagen, Maurice J. H. M.
2004-01-01
Inoculation of an automated system for rapid identification (ID) and antimicrobial susceptibility testing (AST) directly from positive blood culture bottles will reduce the turnaround time of laboratory diagnosis of septicemic patients, which benefits clinical outcome and decreases patient costs. Direct test results, however, must always be confirmed by testing a pure overnight culture, which is the “gold standard.” We studied the accuracy of direct testing versus repeat testing in order to investigate the possibility of refraining from repeat testing. We also assessed the clinical risk of reporting results based on direct testing only. We inoculated Vitek 2 (bioMérieux) directly from 410 positive BACTEC 9240 (BD) blood culture bottles containing gram-negative rods and studied the ID and AST results. In a comparison of direct inoculation with the standard method, a total of 344 isolates of Enterobacteriaceae and Pseudomonas aeruginosa were tested, and 93.0% were correctly identified. Of the 39 (10.2%) samples that contained bacilli not identifiable by Vitek 2, only 1 gave a conclusive, correct result. The overall MIC agreement among 312 isolates was 99.2%, with 0.8% very major and 0.02% major error rates. Of only three (polymicrobial) samples, the direct susceptibility pattern would be reported to the clinician as too sensitive. Vitek 2 results obtained from direct inoculation of blood culture bottles containing gram-negative bacilli are safe enough for immediate reporting, provided that ID and AST are consistent. Repeat testing is not necessary, unless Gram stain or overnight subculture results raise doubt about the purity of the culture. PMID:14715724
Carey, Roger Neill; Jani, Chinu; Johnson, Curtis; Pearce, Jim; Hui-Ng, Patricia; Lacson, Eduardo
2016-09-07
Plasma samples collected in tubes containing separator gels have replaced serum samples for most chemistry tests in many hospital and commercial laboratories. Use of plasma samples for blood tests in the dialysis population eliminates delays in sample processing while waiting for clotting to complete, laboratory technical issues associated with fibrin formation, repeat sample collection, and patient care issues caused by delay of results because of incompletely clotted specimens. Additionally, a larger volume of plasma is produced than serum for the same amount of blood collected. Plasma samples are also acceptable for most chemical tests involved in the care of patients with ESRD. This information becomes very important when United States regulatory requirements for ESRD inadvertently limit the type of sample that can be used for government reporting, quality assessment, and value-based payment initiatives. In this narrative, we summarize the renal community experience and how the subsequent resolution of the acceptability of phosphorus levels measured from serum and plasma samples may have significant implications in the country's continued development of a value-based Medicare ESRD Quality Incentive Program. Copyright © 2016 by the American Society of Nephrology.
Through-barrier detection of explosive components for security screening applications
NASA Astrophysics Data System (ADS)
Lee, Linda; Frisby, Alex; Mansson, Ralph; Hopkins, Rebecca J.
2011-11-01
The detection of materials through containers is a vital capability for security screening applications at high risk locations, such as airports and checkpoints. Current detection procedures require suspect containers to be opened and the contents sampled, which is laborious and potentially hazardous to the operator. The capability to detect through-barrier would overcome these issues. Spatially Offset Raman Spectroscopy (SORS) is an innovative spectroscopic technique that avoids fluorescence and Raman scatter from containers, which can mask the Raman signature from the sample. This novel approach enables noninvasive detection of hazardous and benign materials through a wider range of container materials than is possible using conventional Raman spectroscopy. SORS spectra were acquired from explosive compounds and benign materials within a range of coloured glass and plastic containers. The SORS spectra were compared to the reference Raman signatures of the materials studied. Two data analysis methods were then applied to the resultant data to investigate the ability of SORS to detect the target materials through the barriers tested. Furthermore, the potential for reduction of sample fluorescence was investigated by using longer excitation wavelength (1064 nm) than is typically used in commercially available Raman instruments that use silicon detector technology. For some fluorescent samples, Raman spectral features that were masked by fluorescence at 785 nm were revealed at 1064 nm.
Environmental Survey of Drinking Water Sources in Kampala, Uganda, during a Typhoid Fever Outbreak.
Murphy, J L; Kahler, A M; Nansubuga, I; Nanyunja, E M; Kaplan, B; Jothikumar, N; Routh, J; Gómez, G A; Mintz, E D; Hill, V R
2017-12-01
In 2015, a typhoid fever outbreak began in downtown Kampala, Uganda, and spread into adjacent districts. In response, an environmental survey of drinking water source types was conducted in areas of the city with high case numbers. A total of 122 samples was collected from 12 source types and tested for Escherichia coli , free chlorine, and conductivity. An additional 37 grab samples from seven source types and 16 paired large volume (20 liter) samples from wells and springs were also collected and tested for the presence of Salmonella enterica serovar Typhi. Escherichia coli was detected in 60% of kaveras (drinking water sold in plastic bags) and 80% of refilled water bottles; free chlorine was not detected in either source type. Most jerry cans (68%) contained E. coli and had free chlorine residuals below the WHO-recommended level of 0.5 mg/liter during outbreaks. Elevated conductivity readings for kaveras, refilled water bottles, and jerry cans (compared to treated surface water supplied by the water utility) suggested that they likely contained untreated groundwater. All unprotected springs and wells and more than 60% of protected springs contained E. coli Water samples collected from the water utility were found to have acceptable free chlorine levels and no detectable E. coli While S Typhi was not detected in water samples, Salmonella spp. were detected in samples from two unprotected springs, one protected spring, and one refilled water bottle. These data provided clear evidence that unregulated vended water and groundwater represented a risk for typhoid transmission. IMPORTANCE Despite the high incidence of typhoid fever globally, relatively few outbreak investigations incorporate drinking water testing. During waterborne disease outbreaks, measurement of physical-chemical parameters, such as free chlorine residual and electrical conductivity, and of microbiological parameters, such as the presence of E. coli or the implicated etiologic agent, in drinking water samples can identify contaminated sources. This investigation indicated that unregulated vended water and groundwater sources were contaminated and were therefore a risk to consumers during the 2015 typhoid fever outbreak in Kampala. Identification of contaminated drinking water sources and sources that do not contain adequate disinfectant levels can lead to rapid targeted interventions. Copyright © 2017 American Society for Microbiology.
An Introduction to Structural Reliability Theory
1989-01-01
Test Samples psi COV Distribution Remarks Yield stress 66 (XX 0.09 assumed lognormal mill test I containment vesel SA537 GrB Yield stress 6W8...straightened shape Tension :32 57.909 0.089 cold straightened shape Tension 9 84.039 0.1124 annealed , alloy steel Tension 9 124,9 0.1796 . quenched...alloys, annealed and quenched, and drawn samples Tension 22 29.50 X 103 0.0072 .. structural steel Compression 22 29.49 X 103 0.0146 ... structural
Spot test for 1,3,5-triamino-2,4,6-trinitrobenzene, TATB
Harris, Betty W.
1986-01-01
A simple, sensitive and specific spot test for 1,3,5-triamino-2,4,6-trinitrobenzene, TATB, is described. Upon the application of the composition of matter of the present invention to samples containing in excess of 0.1 mg of this explosive, a bright orange color results. Interfering species such as TNT and Tetryl can be removed by first treating the sample with a solvent which does not dissolve much of the TATB, but readily dissolves these explosives.
Spot test for 1,3,5-triamino-2,4,6-trinitrobenzene, TATB
Harris, B.W.
1984-11-29
A simple, sensitive and specific spot test for 1,3,5-triamino-2,4,6-trinitrobenzene, TATB, is described. Upon the application of the composition of matter of the subject invention to samples containing in excess of 0.1 mg of this explosive, a bright orange color results. Interfering species such as TNT and Tetryl can be removed by first treating the sample with a solvent which does not dissolve the TATB, but readily dissolves these interfering explosives.
NASA Technical Reports Server (NTRS)
Wilcox, W. R.; Subramanian, R. S.; Meyyappan, M.; Smith, H. D.; Mattox, D. M.; Partlow, D. P.
1981-01-01
Thermal fining, thermal migration of bubbles under reduced gravity conditions, and data to verify current theoretical models of bubble location and temperatures as a function of time are discussed. A sample, sodium borate glass, was tested during 5 to 6 minutes of zero gravity during rocket flight. The test cell contained a heater strip; thermocouples were in the sample. At present quantitative data are insufficient to confirm results of theoretical calculations.
Park, Douglas L; Coates, Scott; Brewer, Vickery A; Garber, Eric A E; Abouzied, Mohamed; Johnson, Kurt; Ritter, Bruce; McKenzie, Deborah
2005-01-01
Performance Tested Method multiple laboratory validations for the detection of peanut protein in 4 different food matrixes were conducted under the auspices of the AOAC Research Institute. In this blind study, 3 commercially available ELISA test kits were validated: Neogen Veratox for Peanut, R-Biopharm RIDASCREEN FAST Peanut, and Tepnel BioKits for Peanut Assay. The food matrixes used were breakfast cereal, cookies, ice cream, and milk chocolate spiked at 0 and 5 ppm peanut. Analyses of the samples were conducted by laboratories representing industry and international and U.S governmental agencies. All 3 commercial test kits successfully identified spiked and peanut-free samples. The validation study required 60 analyses on test samples at the target level 5 microg peanut/g food and 60 analyses at a peanut-free level, which was designed to ensure that the lower 95% confidence limit for the sensitivity and specificity would not be <90%. The probability that a test sample contains an allergen given a prevalence rate of 5% and a positive test result using a single test kit analysis with 95% sensitivity and 95% specificity, which was demonstrated for these test kits, would be 50%. When 2 test kits are run simultaneously on all samples, the probability becomes 95%. It is therefore recommended that all field samples be analyzed with at least 2 of the validated kits.
Geolab Results from Three Years of Analog Mission Tests
NASA Technical Reports Server (NTRS)
Evans, Cindy A.; Bell, M. S.; Calaway, M. J.
2013-01-01
GeoLab is a prototype glovebox for geological sample examination that was, until November 2012, fully integrated into NASA's Deep Space Habitat Analog Testbed [1,2]. GeoLab allowed us to test science operations related to contained sample examination during simulated exploration missions. The facility, shown in Figure 1 and described elsewhere [1-4], was designed for fostering the development of both instrument technology and operational concepts for sample handling and examination during future missions [3-5]. Even though we recently deintegrated the glovebox from the Deep Space Habitat (Fig. 2), it continues to provide a high-fidelity workspace for testing instruments that could be used for sample characterization. As a testbed, GeoLab supports the development of future science operations that will enhance the early scientific returns from exploration missions, and will help ensure selection of the best samples for Earth return.
Quantification of hepatitis C virus RNA in serum by branched DNA-based signal amplification assays.
Pawlotsky, J M; Martinot-Peignoux, M; Poveda, J D; Bastie, A; Le Breton, V; Darthuy, F; Rémiré, J; Erlinger, S; Dhumeaux, D; Marcellin, P
1999-05-01
The objective of the study was to compare the clinical sensitivity and specificity of versions 1.0 and 2.0 of the branched DNA (bDNA)-based hepatitis C virus (HCV) RNA quantification assay, and also to compare the values yielded by the two versions according to the HCV genotype. Serum samples from 268 patients tested routinely by a non-quantitative HCV RNA PCR assay (group A) were tested with version 2.0 of the bDNA assay. Samples from 342 HCV PCR-positive patients with chronic hepatitis C eligible for interferon treatment (group B) were tested with both version 1.0 and version 2.0 of the bDNA assay. Version 2.0 had a clinical sensitivity of 92% (95% confidence interval (CI): 87-97%) in group A and 89% (86-92%) in group B. In group B, the gain in sensitivity with bDNA 2.0 was 16% relative to bDNA 1.0 (P < 0.001). The log values of the two assays correlated with samples positive by both assays (r = 0.83, P < 0.0001), but the distribution of values was larger in samples containing HCV genotypes 2 and 3. The mean ratio of assay 2.0/assay 1.0 values was 1.69 +/- 1.44 (range: 0.33-13.43). The mean ratio was close to 1 with samples containing genotype 1 or 4, but ranged from 0.33 to more than 5. The mean ratio was close to 3 with samples containing genotype 2 or 3, and ranged from 0.5 to more than 13. HCV RNA levels were significantly lower in samples containing genotype 4 than in those containing other genotypes. Sera from 200 anti-HCV-negative, HCV RNA PCR-negative blood donors (group C), and from 164 anti-HCV-negative patients with symptoms of chronic liver disease (group D) were used to assess the clinical specificity of bDNA 2.0. In addition, samples with an HCV RNA titer between 0.2 (assay cutoff) and 0.5 MEq/ml from a group of 546 patients tested routinely for HCV RNA load by bDNA 2.0 (group E) were retested by bDNA 2.0 and by qualitative PCR. The specificity of bDNA 2.0 was 100% (98-100%) in group C and 99% (97-100%) in group D. Among the 41 samples from group E, 38 were positive by bDNA 2.0 retesting (36 were PCR-positive) and three were negative by bDNA 2.0 retesting (all were PCR-positive). It is concluded that version 2.0 of the bDNA assay is markedly more sensitive than version 1.0 and has a good specificity. In contrast with version 1.0, version 2.0 is not influenced by the HCV genotype. The relationship between values obtained with assays 1.0 and 2.0 on clinical specimens is not linear, indicating that HCV RNA titers cannot reliably be calculated from the results of version 1.0.
Pedrali, Alice; Bleve, Mariella; Capra, Priscilla; Jonsson, Tobias; Massolini, Gabriella; Perugini, Paola; Marrubini, Giorgio
2015-03-25
N-Acetylglucosamine is an ingredient in pharmaceuticals, nutritional supplements and in cosmetics. N-Acetylglucosamine in cosmetics is expected to improve skin hydration, reparation, and to contribute as anti-wrinkle agent. This study reports on the validation and application of an HPLC method based on HILIC and UV detection for determining N-acetylglucosamine in cosmetics and in samples obtained after testing the skin exposed to cosmetics formulations. The chromatographic column used is a ZIC(®)-pHILIC (150 mm × 4.6 mm, 5 μm particle size) on which a mobile phase containing acetonitrile-aqueous KH2PO4 (70:30, v/v) 15 mM was applied in isocratic elution mode injecting 20 μl of sample at 0.5 ml/min constant flow-rate and 10±1°C column temperature. Under these conditions the total run time was 10 min and N-acetylglucosamine eluted baseline separated from all other compounds in the samples. Calibration in the range from 40 to 80 μg/ml allowed to assess the method linearity (R(2)>0.999) in a concentration range corresponding to about 50% to 120% of the expected levels of N-acetylglucosamine in the formulations. Precision expressed by RSD% was always better than 2% in intra-day and inter-day assays of authentic samples. Accuracy was in all cases within 95-105% of the expected concentration value in formulations containing N-acetylglucosamine. The sensitivity of the method was at the level of 10 μg/ml as limit of detection, and at 40 μg/ml as limit of quantitation. The application of the method to formulations containing solid lipid nanoparticles documents its usefulness in cosmetic quality control. The results witness that the method is also suitable for the determination of N-acetylglucosamine in samples obtained from skin test strips. Copyright © 2014 Elsevier B.V. All rights reserved.
... container in a health care provider’s office or commercial facility and can be tested in the same ... blood at a health care provider’s office or commercial facility and sending the sample to a lab ...
ERIC Educational Resources Information Center
McGovern, Matthew
1989-01-01
Describes structure and use of asbestos; diseases associated with asbestos exposure; legislation and regulations concerning asbestos; training requirements of individuals involved in asbestos abatement; sampling and testing whether a material contains asbestos; and liabilities. (MLF)
A portable molecular-sieve-based CO2 sampling system for radiocarbon measurements
NASA Astrophysics Data System (ADS)
Palonen, V.
2015-12-01
We have developed a field-capable sampling system for the collection of CO2 samples for radiocarbon-concentration measurements. Most target systems in environmental research are limited in volume and CO2 concentration, making conventional flask sampling hard or impossible for radiocarbon studies. The present system captures the CO2 selectively to cartridges containing 13X molecular sieve material. The sampling does not introduce significant under-pressures or significant losses of moisture to the target system, making it suitable for most environmental targets. The system also incorporates a significantly larger sieve container for the removal of CO2 from chambers prior to the CO2 build-up phase and sampling. In addition, both the CO2 and H2O content of the sample gas are measured continuously. This enables in situ estimation of the amount of collected CO2 and the determination of CO2 flux to a chamber. The portable sampling system is described in detail and tests for the reliability of the method are presented.
A portable molecular-sieve-based CO2 sampling system for radiocarbon measurements.
Palonen, V
2015-12-01
We have developed a field-capable sampling system for the collection of CO2 samples for radiocarbon-concentration measurements. Most target systems in environmental research are limited in volume and CO2 concentration, making conventional flask sampling hard or impossible for radiocarbon studies. The present system captures the CO2 selectively to cartridges containing 13X molecular sieve material. The sampling does not introduce significant under-pressures or significant losses of moisture to the target system, making it suitable for most environmental targets. The system also incorporates a significantly larger sieve container for the removal of CO2 from chambers prior to the CO2 build-up phase and sampling. In addition, both the CO2 and H2O content of the sample gas are measured continuously. This enables in situ estimation of the amount of collected CO2 and the determination of CO2 flux to a chamber. The portable sampling system is described in detail and tests for the reliability of the method are presented.
Survey on Metals Contained in Stainless Steel Kitchenware and Tableware.
Shiozawa, Yuu; Haneishi, Nahoko; Suzuki, Kumi; Ogimoto, Mami; Takanashi, Mayu; Tomioka, Naoko; Uematsu, Yoko; Monma, Kimio
2017-01-01
Stainless steel kitchenware and tableware on sale in Japan were investigated. Surface elemental composition ratios of 172 samples were analyzed by the fluorescence X-ray method. High levels of manganese (9.59-20.03%)were detected in 17 samples. This finding was confirmed by ICP analysis. Next, we conducted migration tests. Samples conformed to the Italian Specific Migration Limits. Moreover, lead and antimony were not detected in these samples, in accordance with the Japanese Food Sanitation Law.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wyrwas, Richard B.; Lamothe, Margaret E.
2013-05-30
This report describes the results of the electrochemical testing performed on tank 241-SY-102 (SY-102) grab samples that were collected in support of corrosion mitigation. The objective of the work presented here was to determine corrosion resistance of tank SY-102 to the grab samples collected using electrochemical methods up to 50°C as well as to satisfy data quality objectives. Grab samples were collected at multiple elevations from Riser 003. The electrochemical corrosion testing was planned to consist of linear polarization resistance testing (LPR) and cyclic potentiodynamic polarization (CPP) testing at 50°C. The temperature would be lowered to 40 °C and themore » test repeated if the CPP curve indicated pitting corrosion at 50°C. Ifno pitting was indicated by the CPP curve, then a duplicate scan would be repeated at 50°C to confirm the first result. The testing would be complete if the duplicate CPP scan was consistent with the first. This report contains the CPP results of the testing of grab sample 2SY-12-03 and 2SY-12-03DUP composite sample tested under these conditions. There was no indication of pitting at 50°C, and the duplicate scan was in agreement with the first scan. Since no further testing was required, a third scan with a shorter rest time was performed and is present in this report.« less
A gel-based visual immunoassay for non-instrumental detection of chloramphenicol in food samples.
Yuan, Meng; Sheng, Wei; Zhang, Yan; Wang, Junping; Yang, Yijin; Zhang, Shuguang; Goryacheva, Irina Yu; Wang, Shuo
2012-11-02
A gel-based non-instrumental immuno-affinity assay was developed for the rapid screening of chloramphenicol (CAP) in food samples with the limit of detection (LOD) of 1 μg L(-1). The immuno-affinity test column (IATC) consisted of a test layer containing anti-CAP antibody coupled gel, and a control layer with anti-HRP antibody coupled gel. Based on the direct competitive immuno-reaction and the horseradish peroxidase enzymatic reaction, the test results could be evaluated visually. Basically, blue color development represented the negative results, while the absence of color development represented the positive results. In this study, CAP spiked samples of raw milk, pasteurized milk, UHT milk, skimmed milk powder, acacia honey, date honey, fish and shrimp were tested. Little or none sample pretreatment was required for this assay. The whole procedure was completed within 10min. In conclusion, the gel-based immuno-affinity test is a simple, rapid, and promising on-site screening method for CAP residues in food samples, with no instrumental requirement. Copyright © 2012 Elsevier B.V. All rights reserved.
Stability of Alprostadil in 0.9% Sodium Chloride Stored in Polyvinyl Chloride Containers.
McCluskey, Susan V; Kirkham, Kylian; Munson, Jessica M
2017-01-01
The stability of alprostadil diluted in 0.9% sodium chloride stored in polyvinyl chloride (VIAFLEX) containers at refrigerated temperature, protected from light, is reported. Five solutions of alprostadil 11 mcg/mL were prepared in 250 mL 0.9% sodium chloride polyvinyl chloride (PL146) containers. The final concentration of alcohol was 2%. Samples were stored under refrigeration (2°C to 8°C) with protection from light. Two containers were submitted for potency testing and analyzed in duplicate with the stability-indicating high-performance liquid chromatography assay at specific time points over 14 days. Three containers were submitted for pH and visual testing at specific time points over 14 days. Stability was defined as retention of 90% to 110% of initial alprostadil concentration, with maintenance of the original clear, colorless, and visually particulate-free solution. Study results reported retention of 90% to 110% initial alprostadil concentration at all time points through day 10. One sample exceeded 110% potency at day 14. pH values did not change appreciably over the 14 days. There were no color changes or particle formation detected in the solutions over the study period. This study concluded that during refrigerated, light-protected storage in polyvinyl chloride (VIAFLEX) containers, a commercial alcohol-containing alprostadil formulation diluted to 11 mcg/mL with 0.9% sodium chloride 250 mL was stable for 10 days. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Gatton, Michelle L; Ciketic, Sadmir; Barnwell, John W; Cheng, Qin; Chiodini, Peter L; Incardona, Sandra; Bell, David; Cunningham, Jane; González, Iveth J
2018-01-01
Malaria rapid diagnostic tests (RDTs) can produce false positive (FP) results in patients with human African trypanosomiasis and rheumatoid factor (RF), but specificity against other infectious agents and immunological factors is largely unknown. Low diagnostic specificity caused by cross-reactivity may lead to over-estimates of the number of malaria cases and over-use of antimalarial drugs, at the cost of not diagnosing and treating the true underlying condition. Data from the WHO Malaria RDT Product Testing Programme was analysed to assess FP rates of 221 RDTs against four infectious agents (Chagas, dengue, Leishmaniasis and Schistosomiasis) and four immunological factors (anti-nuclear antibody, human anti-mouse antibody (HAMA), RF and rapid plasma regain). Only RDTs with a FP rate against clean negative samples less than 10% were included. Paired t-tests were used to compare product-specific FP rates on clean negative samples and samples containing non-Plasmodium infectious agents and immunological factors. Forty (18%) RDTs showed no FP results against any tested infectious agent or immunological factor. In the remaining RDTs significant and clinically relevant increases in FP rates were observed for samples containing HAMA and RF (P<0.001). There were significant correlations between product-matched FP rates for RF and HAMA on all RDT test bands (P<0.001), and FP rates for each infectious agent and immunological factor were also correlated between test bands of combination RDTs (P≤0.002). False positive results against non-Plasmodium infectious agents and immunological factors does not appear to be a universal property of malaria RDTs. However, since many malaria RDTs have elevated FP rates against HAMA and RF positive samples practitioners may need to consider the possibility of false positive results for malaria in patients with conditions that stimulate HAMA or RF.
Facility Concepts for Mars Returned Sample Handling
NASA Technical Reports Server (NTRS)
Cohen, Marc M.; Briggs, Geoff (Technical Monitor)
2001-01-01
Samples returned from Mars must be held in quarantine until their biological safety has been determined. A significant challenge, unique to NASA's needs, is how to contain the samples (to protect the blaspheme) while simultaneously protecting their pristine nature. This paper presents a comparative analysis of several quarantine facility concepts for handling and analyzing these samples. The considerations in this design analysis include: modes of manipulation; capability for destructive as well as non-destructive testing; avoidance of cross-contamination; linear versus recursive processing; and sample storage and retrieval within a closed system. The ability to rigorously contain biologically hazardous materials has been amply demonstrated by facilities that meet the specifications of the Center for Disease Control Biosafety Level 4. The newly defined Planetary Protection Level Alpha must provide comparable containment while assuring that the samples remain pristine; the latter requirement is based on the need to avoid compromising science analyses by instrumentation of the highest possible sensitivity (among other things this will assure that there is no false positive detection of organisms or organic molecules - a situation that would delay or prevent the release of the samples from quarantine). Protection of the samples against contamination by terrestrial organisms and organic molecules makes a considerable impact upon the sample handling facility. The use of glove boxes appears to be impractical because of their tendency to leak and to surges. As a result, a returned sample quarantine facility must consider the use of automation and remote manipulation to carry out the various functions of sample handling and transfer within the system. The problem of maintaining sensitive and bulky instrumentation under the constraints of simultaneous sample containment and contamination protection also places demands on the architectural configuration of the facility that houses it.
Abruzzo, Lynne V; Barron, Lynn L; Anderson, Keith; Newman, Rachel J; Wierda, William G; O'brien, Susan; Ferrajoli, Alessandra; Luthra, Madan; Talwalkar, Sameer; Luthra, Rajyalakshmi; Jones, Dan; Keating, Michael J; Coombes, Kevin R
2007-09-01
To develop a model incorporating relevant prognostic biomarkers for untreated chronic lymphocytic leukemia patients, we re-analyzed the raw data from four published gene expression profiling studies. We selected 88 candidate biomarkers linked to immunoglobulin heavy-chain variable region gene (IgV(H)) mutation status and produced a reliable and reproducible microfluidics quantitative real-time polymerase chain reaction array. We applied this array to a training set of 29 purified samples from previously untreated patients. In an unsupervised analysis, the samples clustered into two groups. Using a cutoff point of 2% homology to the germline IgV(H) sequence, one group contained all 14 IgV(H)-unmutated samples; the other contained all 15 mutated samples. We confirmed the differential expression of 37 of the candidate biomarkers using two-sample t-tests. Next, we constructed 16 different models to predict IgV(H) mutation status and evaluated their performance on an independent test set of 20 new samples. Nine models correctly classified 11 of 11 IgV(H)-mutated cases and eight of nine IgV(H)-unmutated cases, with some models using three to seven genes. Thus, we can classify cases with 95% accuracy based on the expression of as few as three genes.
Gniewosz, Małgorzata; Kraśniewska, Karolina; Woreta, Marcin; Kosakowska, Olga
2013-08-01
This research evaluated the antimicrobial efficacy of pullulan films containing caraway essential oil (CEO). The films were prepared from a 10% of pullulan, containing from 0.12% to 10.0% of CEO. The composition of the CEO was analyzed with the use of gas chromatography. The antimicrobial activity of the CEO was evaluated with the method of serial microdilutions, and the films containing CEO-with the agar diffusion method against selected Gram-negative, Gram-positive bacteria, and fungi. The structure of the film surface and its cross-section were analyzed using a scanning electron microscope (SEM). Analyses were also carried out to determine the efficacy of a pullulan coating with 10% CEO on baby carrots experimentally inoculated with Salmonella enteritidis, Staphylococcus aureus, Saccharomyces cerevisiae, or Aspergillus niger and stored at a room temperature for 7 d. At a concentration of 0.12%, CEO inhibited the growth of all the tested microorganisms. Pullulan films containing 8% to 10% of CEO were active against all tested microorganisms. Populations of S. aureus on carrot samples were reduced by approximately 3 log CFU/g, while those of A. niger and S. cerevisiae by, respectively, 5 and 4 log CFU/g, after 7 d of storage. S. enteritidis was the most resistant among the tested species, since it was not significantly reduced after 7 d of storage. At the end of storage, samples treated with pullulan-caraway oil coating maintained better visual acceptability than control samples. Results of this study suggest the feasibility of applying a pullulan film with incorporated CEO to extend the microbiological stability of minimally processed foods. © 2013 Institute of Food Technologists®
NG09 And CTBT On-Site Inspection Noble Gas Sampling and Analysis Requirements
NASA Astrophysics Data System (ADS)
Carrigan, Charles R.; Tanaka, Junichi
2010-05-01
A provision of the Comprehensive Test Ban Treaty (CTBT) allows on-site inspections (OSIs) of suspect nuclear sites to determine if the occurrence of a detected event is nuclear in origin. For an underground nuclear explosion (UNE), the potential success of an OSI depends significantly on the containment scenario of the alleged event as well as the application of air and soil-gas radionuclide sampling techniques in a manner that takes into account both the suspect site geology and the gas transport physics. UNE scenarios may be broadly divided into categories involving the level of containment. The simplest to detect is a UNE that vents a significant portion of its radionuclide inventory and is readily detectable at distance by the International Monitoring System (IMS). The most well contained subsurface events will only be detectable during an OSI. In such cases, 37 Ar and radioactive xenon cavity gases may reach the surface through either "micro-seepage" or the barometric pumping process and only the careful siting of sampling locations, timing of sampling and application of the most site-appropriate atmospheric and soil-gas capturing methods will result in a confirmatory signal. The OSI noble gas field tests NG09 was recently held in Stupava, Slovakia to consider, in addition to other field sampling and analysis techniques, drilling and subsurface noble gas extraction methods that might be applied during an OSI. One of the experiments focused on challenges to soil-gas sampling near the soil-atmosphere interface. During withdrawal of soil gas from shallow, subsurface sample points, atmospheric dilution of the sample and the potential for introduction of unwanted atmospheric gases were considered. Tests were designed to evaluate surface infiltration and the ability of inflatable well-packers to seal out atmospheric gases during sample acquisition. We discuss these tests along with some model-based predictions regarding infiltration under different near-surface hydrologic conditions. We also consider how naturally occurring as well as introduced (e.g., SF6) soil-gas tracers might be used to guard against the possibility of atmospheric contamination of soil gases while sampling during an actual OSI. The views expressed here do not necessarily reflect the opinion of the United States Government, the United States Department of Energy, or Lawrence Livermore National Laboratory. This work has been performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. LLNL-ABS-418791
Application of drilling, coring, and sampling techniques to test holes and wells
Shuter, Eugene; Teasdale, Warren E.
1989-01-01
The purpose of this manual is to provide ground-water hydrologists with a working knowledge of the techniques of test drilling, auger drilling, coring and sampling, and the related drilling and sampling equipment. For the most part, the techniques discussed deal with drilling, sampling, and completion of test holes in unconsolidated sediments because a hydrologist is interested primarily in shallow-aquifer data in this type of lithology. Successful drilling and coring of these materials usually is difficult, and published research information on the subject is not readily available. The authors emphasize in-situ sampling of unconsolidated sediments to obtain virtually undisturbed samples. Particular attention is given to auger drilling and hydraulic-rotary methods of drilling because these are the principal means of test drilling performed by the U.S. Geological Survey during hydrologic studies. Techniques for sampling areas contaminated by solid or liquid waste are discussed. Basic concepts of well development and a detailed discussion of drilling muds, as related to hole conditioning, also are included in the report. The information contained in this manual is intended to help ground-water hydrologists obtain useful subsurface data and samples from their drilling programs.
A Holographic Prism Based on Photo-Thermo-Refractive Glass: Requirements and Possibilities
NASA Astrophysics Data System (ADS)
Angervaks, A. E.; Gorokhovskii, K. S.; Granovskii, V. A.; Van Bac, Doan; Ivanov, S. A.; Okun', R. A.; Nikonorov, N. V.; Ryskin, A. I.
2017-12-01
A technology for multivalued holographic measurement of a plane angle—a holographic prism, which serves as the basis for a device for calibrating the testing tools for navigational equipment under rolling— has been developed. The holographic prism is a miniature sample of photosensitive material, which contains a system of superimposed holographic gratings, and a laser the radiation of which passes through gratings to form a fan of diffracted beams. The fan in a prism based on a calcium fluoride (fluorite) crystal with color centers contained six out-of-plane beams radiating from a region with a hard-to-localize center. This fact hindered calibration of the measure and its application in the testing device. The use of photothermo-refractive glass as a material for preparing a sample and recording a system of holograms in it makes it possible to eliminate the drawbacks of fluorite-based prism. The number of holograms rises up to 21, the fan becomes in-plane, and its center is localized in a small region, with a size of several tenths of the sample thickness (1-2 mm). The fan beams are energetically homogeneous, and each can be identified when using the fan in a testing device.
High-Temperature Cyclic Oxidation Data, Volume 1
NASA Technical Reports Server (NTRS)
Barrett, C. A.; Garlick, R. G.; Lowell, C. E.
1984-01-01
This first in a series of cyclic oxidation handbooks contains specific-weight-change-versus-time data and X-ray diffraction results derived from high-temperature cyclic tests on high-temperature, high-strength nickel-base gamma/gamma' and cobalt-base turbine alloys. Each page of data summarizes a complete test on a given alloy sample.
40 CFR 745.225 - Accreditation of training programs: target housing and child-occupied facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... equipment to be used for lecture and hands-on training. (B) A copy of the course test blueprint for each..., the delivery of the lecture, course test, hands-on training, and assessment activities. This includes... containment and cleanup methods, and post-renovation cleaning verification. (vii) The dust sampling technician...
40 CFR 745.225 - Accreditation of training programs: target housing and child-occupied facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... equipment to be used for lecture and hands-on training. (B) A copy of the course test blueprint for each..., the delivery of the lecture, course test, hands-on training, and assessment activities. This includes... containment and cleanup methods, and post-renovation cleaning verification. (vii) The dust sampling technician...
9 CFR 113.122 - Salmonella Choleraesuis Bacterin.
Code of Federal Regulations, 2010 CFR
2010-01-01
... container samples of completed product from each serial shall be tested for potency using the mouse test provided in this paragraph. A mouse dose shall be 1/20 of the least dose recommended on the label for other... protect mice shall be compared with a Standard Reference Bacterin (Standard) which is either supplied by...
9 CFR 113.122 - Salmonella Choleraesuis Bacterin.
Code of Federal Regulations, 2011 CFR
2011-01-01
... container samples of completed product from each serial shall be tested for potency using the mouse test provided in this paragraph. A mouse dose shall be 1/20 of the least dose recommended on the label for other... protect mice shall be compared with a Standard Reference Bacterin (Standard) which is either supplied by...
9 CFR 113.122 - Salmonella Choleraesuis Bacterin.
Code of Federal Regulations, 2013 CFR
2013-01-01
... container samples of completed product from each serial shall be tested for potency using the mouse test provided in this paragraph. A mouse dose shall be 1/20 of the least dose recommended on the label for other... protect mice shall be compared with a Standard Reference Bacterin (Standard) which is either supplied by...
9 CFR 113.122 - Salmonella Choleraesuis Bacterin.
Code of Federal Regulations, 2014 CFR
2014-01-01
... container samples of completed product from each serial shall be tested for potency using the mouse test provided in this paragraph. A mouse dose shall be 1/20 of the least dose recommended on the label for other... protect mice shall be compared with a Standard Reference Bacterin (Standard) which is either supplied by...
9 CFR 113.122 - Salmonella Choleraesuis Bacterin.
Code of Federal Regulations, 2012 CFR
2012-01-01
... container samples of completed product from each serial shall be tested for potency using the mouse test provided in this paragraph. A mouse dose shall be 1/20 of the least dose recommended on the label for other... protect mice shall be compared with a Standard Reference Bacterin (Standard) which is either supplied by...
NASA Astrophysics Data System (ADS)
Hsu, Jen-Hsien; Bai, Jincheng; Kim, Cheol-Woon; Brow, Richard K.; Szabo, Joe; Zervos, Adam
2018-03-01
The effects of cooling rate on the chemical durability of iron phosphate waste forms containing up to 40 wt% of a high MoO3 Collins-CLT waste simulant were determined at 90 °C using the product consistency test (PCT). The waste form, designated 40wt%-5, meets appropriate Department of Energy (DOE) standards when rapidly quenched from the melt (as-cast) and after slow cooling following the CCC (canister centerline cooling)-protocol, although the quenched glass is more durable. The analysis of samples from the vapor hydration test (VHT) and the aqueous corrosion test (differential recession test) reveals that rare earth orthophosphate (monazite) and Zr-pyrophosphate crystals that form on cooling are more durable than the residual glass in the 40wt%-5 waste form. The residual glass in the CCC-treated samples has a greater average phosphate chain length and a lower Fe/P ratio, and those contribute to its faster corrosion kinetics.
Effects of Gas Pressure on the Failure Characteristics of Coal
NASA Astrophysics Data System (ADS)
Xie, Guangxiang; Yin, Zhiqiang; Wang, Lei; Hu, Zuxiang; Zhu, Chuanqi
2017-07-01
Several experiments were conducted using self-developed equipment for visual gas-solid coupling mechanics. The raw coal specimens were stored in a container filled with gas (99% CH4) under different initial gas pressure conditions (0.0, 0.5, 1.0, and 1.5 MPa) for 24 h prior to testing. Then, the specimens were tested in a rock-testing machine, and the mechanical properties, surface deformation and failure modes were recorded using strain gauges, an acoustic emission (AE) system and a camera. An analysis of the fractals of fragments and dissipated energy was performed to understand the changes observed in the stress-strain and crack propagation behaviour of the gas-containing coal specimens. The results demonstrate that increased gas pressure leads to a reduction in the uniaxial compression strength (UCS) of gas-containing coal and the critical dilatancy stress. The AE, surface deformation and fractal analysis results show that the failure mode changes during the gas state. Interestingly, a higher initial gas pressure will cause the damaged cracks and failure of the gas-containing coal samples to become severe. The dissipated energy characteristic in the failure process of a gas-containing coal sample is analysed using a combination of fractal theory and energy principles. Using the theory of fracture mechanics, based on theoretical analyses and calculations, the stress intensity factor of crack tips increases as the gas pressure increases, which is the main cause of the reduction in the UCS and critical dilatancy stress and explains the influence of gas in coal failure. More serious failure is created in gas-containing coal under a high gas pressure and low exterior load.
... container in a health care provider’s office or commercial facility and can be tested in the same ... blood at a health care provider’s office or commercial facility and sending the sample to a lab ...
How-to-Do-It: A Biology Composite Guidebook.
ERIC Educational Resources Information Center
Stencel, John E.
1989-01-01
Describes the use of a biology guidebook which contains a course outline, syllabus, reading list, handouts, and sample tests all bound together in booklet form for better organization and teacher effectiveness. (RT)
How Significant Is a Boxplot Outlier?
ERIC Educational Resources Information Center
Dawson, Robert
2011-01-01
It is common to consider Tukey's schematic ("full") boxplot as an informal test for the existence of outliers. While the procedure is useful, it should be used with caution, as at least 30% of samples from a normally-distributed population of any size will be flagged as containing an outlier, while for small samples (N less than 10) even extreme…
Underwater Sediment Sampling Research
2017-01-01
resolved through further experimentation . Underwater Sediment Sampling Research vi UNCLAS//Public | CG-926 RDC | A. Hanson, et al. Public...Chemical Oceanographer, and In situ Chemical Analysis Subject Matter Expert (SME). 2 LABORATORY TEST SET UP The experimental research and laboratory... methodology involved using a fluorescence oil sensor (Turner Designs Cyclops-7) to measure the TPH contained in the interstitial waters (i.e., pore
DITT: a computer program for Data Interpretation for Torsional Tests
Chen, Albert T.F.
1979-01-01
Measurements of the helium concentration of soil samples collected and stored in Vacutainer-brand evacuated glass tubes show that Vacutainers are reliable containers for soil collection. Within the limits of reproducibility, helium content of soils appears to be independent of variations in soil temperature, barometric pressure, and quantity of soil moisture present in the sample.
A manual 24-h integrated method for determining SO2, NOx, and CO2 in emissions from electric utility plants was developed and field tested downstream from an SO2 control system. Samples were collected in alkaline potassium permanganate solution contained in restricted-orifice imp...
Students’ Conception on Heat and Temperature toward Science Process Skill
NASA Astrophysics Data System (ADS)
Ratnasari, D.; Sukarmin, S.; Suparmi, S.; Aminah, N. S.
2017-09-01
This research is aimed to analyze the effect of students’ conception toward science process skill. This is a descriptive research with subjects of the research were 10th-grade students in Surakarta from high, medium and low categorized school. The sample selection uses purposive sampling technique based on physics score in national examination four latest years. Data in this research collecting from essay test, two-tier multiple choice test, and interview. Two-tier multiple choice test consists of 30 question that contains an indicator of science process skill. Based on the result of the research and analysis, it shows that students’ conception of heat and temperature affect science process skill of students. The students’ conception that still contains the wrong concept can emerge misconception. For the future research, it is suggested to improve students’ conceptual understanding and students’ science process skill with appropriate learning method and assessment instrument because heat and temperature is one of physics material that closely related with students’ daily life.
Reuse of municipal solid wastes incineration fly ashes in concrete mixtures.
Collivignarelli, Carlo; Sorlini, Sabrina
2002-01-01
This study is aimed at assessing the feasibility of concrete production using stabilized m.s.w. (municipal solid waste) incineration fly ashes in addition to natural aggregates. The tested fly ashes were washed and milled, then stabilized by a cement-lime process and finally were reused as a "recycled aggregate" for cement mixture production, in substitution of a natural aggregate (with dosage of 200-400 kg m(-3)). These mixtures, after curing, were characterized with conventional physical-mechanical tests (compression, traction, flexure, modulus of elasticity, shrinkage). In samples containing 200 kg(waste) m(-3)(concrete), a good compressive strength was achieved after 28 days of curing. Furthermore, concrete leaching behavior was evaluated by means of different leaching tests, both on milled and on monolithic samples. Experimental results showed a remarkable reduction of metal leaching in comparison with raw waste. In some cases, similar behavior was observed in "natural" concrete (produced with natural aggregates) and in "waste containing" concrete.
Intragastric inulin as a measure of mucosal damage caused by aspirin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wittmers, L.E. Jr.; Anderson, L.A.; Fall, M.M.
In an attempt to find a method of gastric mucosal damage assessment that yields consistent results, the experiments presented here employed the measurement of the movement of inulin out of the gastric contents into the stomach wall and vascular compartment as an estimate of mucosal damage. Anesthetized male Sprague-Dawley rats were functionally nephrectomized and were administered a control or test solution containing 3H-inulin. The test solutions contained one of three doses of aspirin. Blood samples were taken at 15-min intervals over a 90-min exposure period. The stomach was removed from the animal and full-thickness tissue samples taken for measurement ofmore » 3H-inulin content. When the gastric mucosa was exposed to the test agents, there was a significantly greater accumulation of inulin in the body and antrum as well as in the plasma when compared to controls. We conclude that intragastric inulin can be employed to estimate gastric mucosal damage.« less
Yang, Lei; Zhou, Weihua; Xue, Kaihua; Wei, Rupeng; Ling, Zheng
2018-05-01
The enormous potential as an alternative energy resource has made natural gas hydrates a material of intense research interest. Their exploration and sample characterization require a quick and effective analysis of the hydrate-bearing cores recovered under in situ pressures. Here a novel Pressure Core Ultrasonic Test System (PCUTS) for on-board analysis of sediment cores containing gas hydrates at in situ pressures is presented. The PCUTS is designed to be compatible with an on-board pressure core transfer device and a long gravity-piston pressure-retained corer. It provides several advantages over laboratory core analysis including quick and non-destructive detection, in situ and successive acoustic property acquisition, and remission of sample storage and transportation. The design of the unique assembly units to ensure the in situ detection is demonstrated, involving the U-type protecting jackets, transducer precession device, and pressure stabilization system. The in situ P-wave velocity measurements make the detection of gas hydrate existence in the sediments possible on-board. Performance tests have verified the feasibility and sensitivity of the ultrasonic test unit, showing the dependence of P-wave velocity on gas hydrate saturation. The PCUTS has been successfully applied for analysis of natural samples containing gas hydrates recovered from the South China Sea. It is indicated that on-board P-wave measurements could provide a quick and effective understanding of the hydrate occurrence in natural samples, which can assist further resource exploration, assessment, and subsequent detailed core analysis.
NASA Astrophysics Data System (ADS)
Yang, Lei; Zhou, Weihua; Xue, Kaihua; Wei, Rupeng; Ling, Zheng
2018-05-01
The enormous potential as an alternative energy resource has made natural gas hydrates a material of intense research interest. Their exploration and sample characterization require a quick and effective analysis of the hydrate-bearing cores recovered under in situ pressures. Here a novel Pressure Core Ultrasonic Test System (PCUTS) for on-board analysis of sediment cores containing gas hydrates at in situ pressures is presented. The PCUTS is designed to be compatible with an on-board pressure core transfer device and a long gravity-piston pressure-retained corer. It provides several advantages over laboratory core analysis including quick and non-destructive detection, in situ and successive acoustic property acquisition, and remission of sample storage and transportation. The design of the unique assembly units to ensure the in situ detection is demonstrated, involving the U-type protecting jackets, transducer precession device, and pressure stabilization system. The in situ P-wave velocity measurements make the detection of gas hydrate existence in the sediments possible on-board. Performance tests have verified the feasibility and sensitivity of the ultrasonic test unit, showing the dependence of P-wave velocity on gas hydrate saturation. The PCUTS has been successfully applied for analysis of natural samples containing gas hydrates recovered from the South China Sea. It is indicated that on-board P-wave measurements could provide a quick and effective understanding of the hydrate occurrence in natural samples, which can assist further resource exploration, assessment, and subsequent detailed core analysis.
Gluten-containing grains skew gluten assessment in oats due to sample grind non-homogeneity.
Fritz, Ronald D; Chen, Yumin; Contreras, Veronica
2017-02-01
Oats are easily contaminated with gluten-rich kernels of wheat, rye and barley. These contaminants are like gluten 'pills', shown here to skew gluten analysis results. Using R-Biopharm R5 ELISA, we quantified gluten in gluten-free oatmeal servings from an in-market survey. For samples with a 5-20ppm reading on a first test, replicate analyses provided results ranging <5ppm to >160ppm. This suggests sample grinding may inadequately disperse gluten to allow a single accurate gluten assessment. To ascertain this, and characterize the distribution of 0.25-g gluten test results for kernel contaminated oats, twelve 50g samples of pure oats, each spiked with a wheat kernel, showed that 0.25g test results followed log-normal-like distributions. With this, we estimate probabilities of mis-assessment for a 'single measure/sample' relative to the <20ppm regulatory threshold, and derive an equation relating the probability of mis-assessment to sample average gluten content. Copyright © 2016 Elsevier Ltd. All rights reserved.
Decontaminating materials used in ground water sampling devices: Organic contaminants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parker, L.V.; Ranney, T.A.
2000-12-31
In these studies, the efficiency of various decontamination protocols was tested on small pieces of materials commonly used in ground water sampling devices. Three materials, which ranged in ability to sorb organic solutes, were tested: stainless steel (SS), rigid polyvinyl chloride (PVC), and polytetrafluoroethylene (PTFE). The test pieces were exposed to two aqueous test solutions: One contained three volatile organic compounds (VOCs) and one nitroaromatic compound, and the other contained four pesticides. Also, three types of polymetic tubing were exposed to pesticide solutions. Generally, the contact times were 10 minutes and 24 hours for sorption and desorption. The contaminants weremore » removed from the nonpermeable SS and the less-sorptive rigid PVC test pieces simply by washing with a hot detergent solution and rinsing with hot water. Additional treatment was required for the PTFE test pieces exposed to the VOCs and for the low-density polyethylene (LDPE) tubing exposed to the pesticide test solution. Solvent rinsing did not improve removal of the three VOCs form the PTFE and only marginally improved removal of the residual pesticides from the LDPE. However, a hot water and detergent wash and rinse followed by oven drying at approximately 105 C was effective for removing the VOCs from the PTFE and substantially reduced pesticide contamination from the LDPE.« less
Rock-Magnetic Method for Post Nuclear Detonation Diagnostics
NASA Astrophysics Data System (ADS)
Englert, J.; Petrosky, J.; Bailey, W.; Watts, D. R.; Tauxe, L.; Heger, A. S.
2011-12-01
A magnetic signature characteristic of a Nuclear Electromagnetic Pulse (NEMP) may still be detectable near the sites of atmospheric nuclear tests conducted at what is now the Nevada National Security Site. This signature is due to a secondary magnetization component of the natural remanent magnetization of material containing traces of ferromagnetic particles that have been exposed to a strong pulse of magnetic field. We apply a rock-magnetic method introduced by Verrier et al. (2002), and tested on samples exposed to artificial lightning, to samples of rock and building materials (e.g. bricks, concrete) retrieved from several above ground nuclear test sites. The results of magnetization measurements are compared to NEMP simulations and historic test measurements.
False-positive LSD testing in urine samples from intensive care patients.
Röhrich, J; Zörntlein, S; Lotz, J; Becker, J; Kern, T; Rittner, C
1998-09-01
Unexpected positive results for lysergic acid diethylamide (LSD) were found in urine samples from 12 patients in an intensive care unit in a routine screening using the CEDIA DAU assay. None of these test results could be confirmed by high-performance liquid chromatography analysis, but all samples contained the mucolytic drug ambroxol. Further studies demonstrated that ambroxol exhibits a significant cross-reactivity in the CEDIA DAU LSD assay. Therefore, positive LSD results obtained with the CEDIA DAU assay have to be critically evaluated, particularly during the cold season, when infections of the respiratory tract often result in more frequent use of mucolytic medications.
Significance of pregnancy test false negative results due to elevated levels of β-core fragment hCG.
Johnson, Sarah; Eapen, Saji; Smith, Peter; Warren, Graham; Zinaman, Michael
2017-01-01
Very high levels of β-core fragment human chorionic gonadotrophin (βcf-hCG) are reported to potentially cause false negative results in point-of-care (POC)/over-the-counter (OTC) pregnancy tests. To investigate this further, women's daily early morning urine samples, collected prior to conception and during pregnancy, were analysed for intact, free β-, and βcf-hCG. The proportion of βcf-hCG was found to be related to that of hCG produced and in circulation. Therefore, best practice for accuracy testing of POC/OTC pregnancy tests would be to test devices against clinical samples containing high levels of βcf-hCG as well as standards spiked with biologically relevant ratios.
The effects of storing and transporting cryopreserved semen samples on dry ice.
Til, David; Amaral, Vera L L; Salvador, Rafael A; Senn, Alfred; Paula, Thais S de
2016-12-01
This study aimed to test the effects on sperm viability of transporting cryopreserved semen samples on dry ice. Twenty normozoospermic semen samples were cryopreserved and divided into five groups. The samples in Group 1 were immersed in liquid nitrogen throughout the experiment in cryogenic storage tanks; the cryopreserved straws in Group 2 were placed in a Styrofoam box containing dry ice and kept under these conditions for 48 hours; the samples in Group 3 were kept for 48 hours on dry ice under the same conditions as the Group 2 samples, and were then moved to a storage tank filled with liquid nitrogen; Group 4 samples were also kept for 48 hours in dry ice storage, and the Styrofoam box containing the samples was shipped by plane to assess the effects of shipping; the samples in Group 5 were shipped together with the Group 4 samples and were placed in a storage tank with liquid nitrogen after spending 48 hours stored on dry ice. After thawing, sperm parameters were analyzed for viability, vitality, and motility; spermatozoa were also tested for mitochondrial activity. Significant decreases in motility recovery rates (P=0.01) and vitality (P=0.001) were observed in all groups when compared to the control group. Mitochondrial activity was significantly decreased only in Group 5 (P=0.04), as evidenced by greater numbers of sperm cells not stained by reagent 3,3'-diaminobenzidine. Transportation did not affect the quality of cryopreserved semen samples, but dry ice as a means to preserve the samples during transportation had detrimental effects upon the sperm parameters assessed in this study.
Creep Behavior of Poly(lactic acid) Based Biocomposites
Morreale, Marco; Mistretta, Maria Chiara; Fiore, Vincenzo
2017-01-01
Polymer composites containing natural fibers are receiving growing attention as possible alternatives for composites containing synthetic fibers. The use of biodegradable matrices obtained from renewable sources in replacement for synthetic ones is also increasing. However, only limited information is available about the creep behavior of the obtained composites. In this work, the tensile creep behavior of PLA based composites, containing flax and jute twill weave woven fabrics, produced through compression molding, was investigated. Tensile creep tests were performed at different temperatures (i.e., 40 and 60 °C). The results showed that the creep behavior of the composites is strongly influenced by the temperature and the woven fabrics used. As preliminary characterization, quasi-static tensile tests and dynamic mechanical tests were carried out on the composites. Furthermore, fabrics (both flax and jute) were tested as received by means of quasi-static tests and creep tests to evaluate the influence of fabrics mechanical behavior on the mechanical response of the resulting composites. The morphological analysis of the fracture surface of the tensile samples showed the better fiber-matrix adhesion between PLA and jute fabric. PMID:28772755
Creep Behavior of Poly(lactic acid) Based Biocomposites.
Morreale, Marco; Mistretta, Maria Chiara; Fiore, Vincenzo
2017-04-08
Polymer composites containing natural fibers are receiving growing attention as possible alternatives for composites containing synthetic fibers. The use of biodegradable matrices obtained from renewable sources in replacement for synthetic ones is also increasing. However, only limited information is available about the creep behavior of the obtained composites. In this work, the tensile creep behavior of PLA based composites, containing flax and jute twill weave woven fabrics, produced through compression molding, was investigated. Tensile creep tests were performed at different temperatures (i.e., 40 and 60 °C). The results showed that the creep behavior of the composites is strongly influenced by the temperature and the woven fabrics used. As preliminary characterization, quasi-static tensile tests and dynamic mechanical tests were carried out on the composites. Furthermore, fabrics (both flax and jute) were tested as received by means of quasi-static tests and creep tests to evaluate the influence of fabrics mechanical behavior on the mechanical response of the resulting composites. The morphological analysis of the fracture surface of the tensile samples showed the better fiber-matrix adhesion between PLA and jute fabric.
Dynamic Finite Element Predictions for Mars Sample Return Cellular Impact Test #4
NASA Technical Reports Server (NTRS)
Fasanella, Edwin L.; Billings, Marcus D.
2001-01-01
The nonlinear finite element program MSC.Dytran was used to predict the impact pulse for (he drop test of an energy absorbing cellular structure. This pre-test simulation was performed to aid in the design of an energy absorbing concept for a highly reliable passive Earth Entry Vehicle (EEV) that will directly impact the Earth without a parachute. In addition, a goal of the simulation was to bound the acceleration pulse produced and delivered to the simulated space cargo container. EEV's are designed to return materials from asteroids, comets, or planets for laboratory analysis on Earth. The EEV concept uses an energy absorbing cellular structure designed to contain and limit the acceleration of space exploration samples during Earth impact. The spherical shaped cellular structure is composed of solid hexagonal and pentagonal foam-filled cells with hybrid graphite-epoxy/Kevlar cell walls. Space samples fit inside a smaller sphere at the enter of the EEV's cellular structure. The material models and failure criteria were varied to determine their effect on the resulting acceleration pulse. Pre-test analytical predictions using MSC.Dytran were compared with the test results obtained from impact test #4 using bungee accelerator located at the NASA Langley Research Center Impact Dynamics Research Facility. The material model used to represent the foam and the proper failure criteria for the cell walls were critical in predicting the impact loads of the cellular structure. It was determined that a FOAMI model for the foam and a 20% failure strain criteria for the cell walls gave an accurate prediction of the acceleration pulse for drop test #4.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crawford, C. L.; Cozzi, A. D.; Hill, K. A.
2016-06-01
The primary disposition path of Low Activity Waste (LAW) at the DOE Hanford Site is vitrification. A cementitious waste form is one of the alternatives being considered for the supplemental immobilization of the LAW that will not be treated by the primary vitrification facility. Washington River Protection Solutions (WRPS) has been directed to generate and collect data on cementitious or pozzolanic waste forms such as Cast Stone. This report documents the coring and leach testing of monolithic samples cored from an engineering-scale demonstration (ES Demo) with non-radioactive simulants. The ES Demo was performed at SRNL in October of 2013 usingmore » the Scaled Continuous Processing Facility (SCPF) to fill an 8.5 ft. diameter x 3.25 ft. high container with simulated Cast Stone grout. The Cast Stone formulation was chosen from the previous screening tests. Legacy salt solution from previous Hanford salt waste testing was adjusted to correspond to the average LAW composition generated from the Hanford Tank Waste Operation Simulator (HTWOS). The dry blend materials, ordinary portland cement (OPC), Class F fly ash, and ground granulated blast furnace slag (GGBFS or BFS), were obtained from Lafarge North America in Pasco, WA. In 2014 core samples originally obtained approximately six months after filling the ES Demo were tested along with bench scale molded samples that were collected during the original pour. A latter set of core samples were obtained in late March of 2015, eighteen months after completion of the original ES Demo. Core samples were obtained using a 2” diameter x 11” long coring bit. The ES Demo was sampled in three different regions consisting of an outer ring, a middle ring and an inner core zone. Cores from these three lateral zones were further segregated into upper, middle and lower vertical segments. Monolithic core samples were tested using the Environmental Protection Agency (EPA) Method 1315, which is designed to provide mass transfer rates (release rates) of inorganic analytes contained in monolithic material under diffusion controlled release conditions as a function of leaching time. Compressive strength measurements and drying tests were also performed on the 2015 samples. Leachability indices reported are based on analyte concentrations determined from dissolution of the dried samples.« less
Post-Decontamination Vapor Sampling and Analytical Test Methods
2015-08-12
construction materials (e.g., acrylic, stainless steel , glass, etc.) for containing the chemical contaminants, coupons, coupon holders, and decontaminant(s...made of inert materials, e.g., stainless steel , T6061 aluminum, or equivalent. The construction material may be treated to further minimize...include glove ports. The chamber may have certified fume hoods for the containment of toxic chemicals. All exhaust air must be filtered to
Meeran, Nazeer Ahmed; George, Ashwin Mathew
2013-01-01
Alcohol is known to degrade and dissolve the bisphenol A glycidyl methacrylate present in the composite resin. The effect of alcohol containing mouthrinses on the shear bond strength of orthodontic metal brackets bonded with composite resin has not been verified until date and is the purpose of this study. The aims and objectives of the present study were to evaluate (1) Whether there is a significant difference in the shear bond strength of metal orthodontic brackets after the 1 year (12 h) and 2 years simulation (24 h) of mouth rinsing with 4 different commercially available mouthrinses (2 alcoholic and 2 alcohol-free mouthrinses) when compared to the control. (2) Whether alcohol containing mouthrinses have more adverse effect on the shear bond strength when compared with alcohol-free mouthrinses. (3) To assess the site of bond failure using adhesive remnant index. Experimental - laboratory based. A total of 100 upper premolars extracted for orthodontic purpose were collected immediately after extraction, cleared soft-tissue debris and blood and immediately stored in distilled water with 0.1% thymol crystals added to inhibit bacterial growth. Two alcohol containing mouthrinses and two alcohol-free mouthrinses were used and the bonded teeth were placed in the mouthrinses for a stipulated period of time (1 year simulation and 2 years simulation) and shear bond strength were tested using Lloyd Universal Testing Machine. The data were analyzed using analysis of variance and paired samples t-test. After the 1 year and 2 years simulation time, samples stored in alcohol containing mouthrinses showed lower bond strength (P < 0.05) when compared to samples stored in alcohol free mouthrinses and distilled water (control). Alcohol containing mouthrinses affect the shear bond strength of the metal orthodontic brackets bonded with composite resin (Transbond XT in the present study), more when compared with alcohol-free mouthrinses. It is, therefore, highly advisable to avoid alcohol containing mouthrinses in patients undergoing orthodontic treatment and use alcohol-free mouthrinses as adjuncts to regular oral hygiene procedures for maintaining good enamel integrity and periodontal health, without compromising the shear bond strength of the bonded metal brackets.
Baxter, G A; O'Connor, M C; Haughey, S A; Crooks, S R; Elliott, C T
1999-09-01
A study was conducted to determine the feasibility of performing "on-site" screening for sulfamethazine (SMT), at an abattoir, using a rapid immunobiosensor method. This involved transfer of the biosensor technology and an assay developed in the laboratory, to the cold, humid conditions of a modern pig-processing factory. A pre-determined threshold limit of 0.4 microgram ml-1 SMT in bile was used to identify the likelihood that corresponding tissue samples contained SMT concentrations in excess of the European maximum permissible residue limit of 0.1 mg kg-1. Bile samples containing SMT concentrations above the threshold limit were deemed positive and the corresponding kidney and muscle samples were sent to the laboratory for HPLC analysis. The robustness of the biosensor instrumentation in the harsh operating conditions was monitored throughout the project. The performance of the assay, on-site, was assessed by the regular inclusion of QA samples and by the submission of control 'SMT-positive' pigs to the abattoir. Sampling procedures, identification and traceability were also under scrutiny. During the project, 337 (9.35%) of the total kill were tested for SMT residues, representing 75% of all producers submitting pigs for slaughter. Twelve animals, including the ten controls, gave positive bile results. HPLC analysis confirmed SMT residues in all 12 kidneys (11 in excess of the permissible level). Ten muscle samples also contained violative SMT levels. Throughout the project, the biosensor performed reliably, with no adverse reaction of any mechanical or electrical components. The SMT assay also performed reliably. This is the first report of a biosensor being used for 'on-site' drug screening.
Survey of South African fruit juices using a fast screening HILIC-MS method.
Stander, Marietjie A; Kühn, Wernich; Hiten, Nicholas F
2013-01-01
Adulteration of fruit juices--by the addition of sugar or other less expensive fruit juices as well as preservatives, artificial sweeteners and colours--was tested for by using a developed screening method. The method employs hydrophilic interaction liquid chromatography-mass spectrometry (HILIC-MS) using electrospray ionisation in the negative mode and ultraviolet light detection. Different fruit juices can be differentiated by the content of marker compounds like sorbitol, certain phenolic molecules and their saccharide profile. This method was used to test 46 fruit juice samples from the retail market as well as 12 control samples. The study focused on the main types of fruit juices consumed on the South African market including apple, orange, grape and blends of these juices with other fruits like mango, pear and guava. Overall, the 46 samples tested mostly agreed with label claims. One grape juice sample was adulterated, probably with apple juice. Natamycin above the legal limits was found in two samples. In addition, two samples contained natamycin and one sample benzoate without it being indicated on the label. The method is well suited as a quick screening method for fruit juice adulteration and if used routinely would reduce fruit juice adulteration without the cost of the current array of tests needed for authenticity testing.
Vermeirssen, Etiënne L M; Campiche, Sophie; Dietschweiler, Conrad; Werner, Inge; Burkhardt, Michael
2018-05-22
To protect house façades from fouling by microorganisms, biocides can be added to a render or paint before it is applied. During driving rain events, these biocides gradually leach out and have the potential to pollute soil or aquatic ecosystems. We studied the leaching behaviour of biocides and toxicity of leachates from renders with either free or encapsulated biocides. Both render types contained equal amounts of terbutryn, 2-octyl-3(2H)-isothiazolinone (OIT) and 4,5-dichloro-2-n-octyl-4-isothiazolino-3-one (DCOIT). Leachate samples were generated over nine immersion cycles according to a European standard and biocides were quantified. The first and ninth samples were tested using bioassays with algae, bacteria and water flea, the first sample with earthworms and springtails. Encapsulation reduced leaching of terbutryn, OIT and DCOIT four-, 17-, and 27-fold. For aquatic organisms, the toxicity of water from render containing encapsulated biocides was always lower than that of render with free biocides. Furthermore, toxicity decreased four- to five-fold over the nine immersion cycles. Inhibition of photosynthesis was the most sensitive endpoint, followed by algal growth rate, bacterial bioluminescence and water flea reproduction. Toxicity to algae was explained by terbutryn and toxicity to bacteria by OIT. None of the samples affected soil organisms. Results demonstrate that combining standardised leaching tests with standardised bioassays is a promising approach to evaluate the ecotoxicity of biocides that leach from façade renders. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Kanda, Seiji; Laimanivong, Sakhone; Shimono, Takaki; Darcy, Andrew Waleluma; Phyaluanglath, Amphay; Mishima, Nobuyuki; Nishiyama, Toshimasa
2017-01-01
We developed a combined conventional polymerase chain reaction (PCR) and real-time PCR (qPCR)-based assay for detecting and discriminating between Opisthorchis viverrini and Haplorchis taichui parasite infections. The first PCR amplifies the mitochondrial cytochrome c oxidase subunit I (COI) genes of parasites, and differential diagnosis is achieved by performing qPCR with specific primers and SYBR Green I. The detection limit of the assay was found to be 2.0 × 102 plasmid copies in a test in which a stool sample was spiked with a single egg, which is equivalent to 5 eggs per gram (EPG). The testing of 34 clinical stool samples that had been demonstrated to contain “Opisthorchis-like” eggs by microscopy showed that the novel assay exhibited a sensitivity of 100% for “Opisthorchis-like” parasitic infections, and 71% and 91% of these samples were found to be infected with O. viverrini and H. taichui, respectively. A further four parasitic infections were diagnosed in the 16 negative samples, and the microscopic findings of these samples were confirmed to be false negatives by sequencing analysis. The assay also displayed high specificity during the testing of 10 samples containing other common parasites. The fact that our qPCR SYBR Green I–based assay detected submicroscopic traces of parasitic DNA and was able to differentiate between parasites that produce eggs with similar morphologies indicates that it has a good potential for development of diagnostic application to use in areas where multiple parasites coexist. PMID:27821695
Test Generation Algorithm for Fault Detection of Analog Circuits Based on Extreme Learning Machine
Zhou, Jingyu; Tian, Shulin; Yang, Chenglin; Ren, Xuelong
2014-01-01
This paper proposes a novel test generation algorithm based on extreme learning machine (ELM), and such algorithm is cost-effective and low-risk for analog device under test (DUT). This method uses test patterns derived from the test generation algorithm to stimulate DUT, and then samples output responses of the DUT for fault classification and detection. The novel ELM-based test generation algorithm proposed in this paper contains mainly three aspects of innovation. Firstly, this algorithm saves time efficiently by classifying response space with ELM. Secondly, this algorithm can avoid reduced test precision efficiently in case of reduction of the number of impulse-response samples. Thirdly, a new process of test signal generator and a test structure in test generation algorithm are presented, and both of them are very simple. Finally, the abovementioned improvement and functioning are confirmed in experiments. PMID:25610458
NASA Technical Reports Server (NTRS)
Obenhuber, D. C.; Huff, T. L.; Rodgers, E. B.
1991-01-01
Analysis of biofilm accumulation, studies of iodine disinfection of biofilm, and the potential for microbially influenced corrosion in the water recovery test (WRT) are presented. The analysis of WRT components showed the presence of biofilms and organic deposits in selected tubing. Water samples from the WRT contained sulfate-reducing and acid-producing organisms implicated in corrosion processes. Corrosion of an aluminum alloy was accelerated in the presence of these water samples, but stainless steel corrosion rates were not accelerated.
EVALUATION OF GLOVEBOX GLOVES FOR EFFECTIVE PERMEATION CONTROL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korinko, P.
A research and development task was undertaken to determine the permeabilities of hydrogen and dry air through different polymeric glove materials that are used to maintain the integrity of glovebox secondary containment. Fifteen different glove samples were obtained from four different manufacturers and samples cut from these gloves were tested. The gloves included baseline butyl rubber, Viton{reg_sign}, Dupont{reg_sign} Hypalon{reg_sign}, polyurethane, as well as composite gloves. The testing indicated that all of the vendor's butyl rubber gloves and the Jung Viton{reg_sign} gloves performed comparably in both gases.
Specific wavelength colorimeter. [for measuring given solute concentration in test sample
NASA Technical Reports Server (NTRS)
Brawner, C. C.; Mcdavid, L. S.; Walsh, J. M. (Inventor)
1974-01-01
A self contained, specific wavelength, single beam colorimeter is described for direct spectrophotometric measurement of the concentration of a given solute in a test sample. An electrical circuit employing a photoconductive cell converts the optical output into a linear, directly readable meter output. The colorimeter is simple to operate and is adapted for use in zero gravity conditions. In a specific application, the colorimeter is designed to analyze the concentration of iodine in potable water carried aboard a space vehicle such as the 4B stage of Skylab.
Reichel, Mirja; Heisig, Peter; Kampf, Günter
2008-01-01
Background Effective neutralization of active agents is essential to obtain valid efficacy results, especially when non-volatile active agents like chlorhexidine digluconate (CHG) are tested. The aim of this study was to determine an effective and non-toxic neutralizing mixture for a propan-1-ol solution containing 2% CHG. Methods Experiments were carried out according to ASTM E 1054-02. The neutralization capacity was tested separately with five challenge microorganisms in suspension, and with a rayon swab carrier. Either 0.5 mL of the antiseptic solution (suspension test) or a saturated swab with the antiseptic solution (carrier test) was added to tryptic soy broth containing neutralizing agents. After the samples were mixed, aliquots were spread immediately and after 3 h of storage at 2 – 8°C onto tryptic soy agar containing a neutralizing mixture. Results The neutralizer was, however, not consistently effective in the suspension test. Immediate spread yielded a valid neutralization with Staphylococcus aureus, Staphylococcus epidermidis and Corynebacterium jeikeium but not with Micrococcus luteus (p < 0.001) and Candida albicans (p < 0.001). A 3-h storage period of the neutralized active agents in suspension resulted in significant carry-over activity of CHG in addition against Staphylococcus epidermidis (p < 0.001) and Corynebacterium jeikeium (p = 0.044). In the carrier test, the neutralizing mixture was found to be effective and non toxic to all challenge microorganisms when spread immediately. However, after 3 h storage of the neutralized active agents significant carry-over activity of CHG against Micrococcus luteus (p = 0.004; Tukey HSD) was observed. Conclusion Without effective neutralization in the sampling fluid, non-volatile active ingredients will continue to reduce the number of surviving microorganisms after antiseptic treatment even if the sampling fluid is kept cold straight after testing. This can result in false-positive antiseptic efficacy data. Attention should be paid during the neutralization validation process to the amount of antiseptic solution, the storage time and to the choice of appropriate and sensitive microorganisms. PMID:19046465
Cunha, Lucas M; Cunha, Mariana M; Leite, Romário C; Silva, Israel J; Oliveira, Paulo R de
2009-01-01
This work aims to compare the performance of corrugated paper and "taquaril" bamboo (Phyllostachys sp.) straw traps for collecting (in sampling) Dermanyssus gallinae in a metal cages battery laying hens. The presence of eggs in the two trap models were compared using a Qui-square test and a proportion confidence interval test. Total daily values of mobile instars gathered in each type of trap were compared using the Wilcoxon's test. The amount of traps containing eggs was not different in neither of the traps (p < 0,05). The number of mobile instars sampled at every two days per trap model was different (p = 0,01). Counting in the corrugated paper traps showed a Gauss distribution histogram and was superior to the values of the bamboo straw traps.
Sample-to-answer palm-sized nucleic acid testing device towards low-cost malaria mass screening.
Choi, Gihoon; Prince, Theodore; Miao, Jun; Cui, Liwang; Guan, Weihua
2018-05-19
The effectiveness of malaria screening and treatment highly depends on the low-cost access to the highly sensitive and specific malaria test. We report a real-time fluorescence nucleic acid testing device for malaria field detection with automated and scalable sample preparation capability. The device consists a compact analyzer and a disposable microfluidic reagent compact disc. The parasite DNA sample preparation and subsequent real-time LAMP detection were seamlessly integrated on a single microfluidic compact disc, driven by energy efficient non-centrifuge based magnetic field interactions. Each disc contains four parallel testing units which could be configured either as four identical tests or as four species-specific tests. When configured as species-specific tests, it could identify two of the most life-threatening malaria species (P. falciparum and P. vivax). The NAT device is capable of processing four samples simultaneously within 50 min turnaround time. It achieves a detection limit of ~0.5 parasites/µl for whole blood, sufficient for detecting asymptomatic parasite carriers. The combination of the sensitivity, specificity, cost, and scalable sample preparation suggests the real-time fluorescence LAMP device could be particularly useful for malaria screening in the field settings. Copyright © 2018 Elsevier B.V. All rights reserved.
4 out of 5 Students Surveyed Would Recommend this Activity (Comparing Chewing Gum Flavor Durations)
ERIC Educational Resources Information Center
Richardson, Mary; Rogness, Neal; Gajewski, Byron
2005-01-01
This paper describes an interactive activity developed for illustrating hypothesis tests on the mean for paired or matched samples. The activity is extended to illustrate assessing normality, the Wilcoxon signed rank test, Kaplan-Meier survival functions, two-way analysis of variance, and the randomized block design. (Contains 6 tables and 13…
Statistical characterization of carbon phenolic prepreg materials, volume 1
NASA Technical Reports Server (NTRS)
Beckley, Don A.; Stites, John, Jr.
1988-01-01
The objective was to characterize several lots of materials used for carbon/carbon and carbon/phenol product manufacture. Volume one is organized into testing categories based on raw material of product form. Each category contains a discussion of the sampling plan, comments and observations on each test method utilized, and a summary of the results obtained each category.
Calfee, M. Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall
2016-01-01
Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration. PMID:27362274
Calfee, M Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall
2016-12-01
Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration.
ERIC Educational Resources Information Center
Brouwer, Henry
2005-01-01
A simple procedure to quickly screen different consumer products for the presence of lead, cadmium, and other metals is described. This screening technique avoids expending a lot of preparation time on samples known to contain low levels of hazardous metals where only samples testing positive for the desired elements need to be analyzed…
Healy-Profitós, Jessica; Lee, Seungjun; Mouhaman, Arabi; Garabed, Rebecca; Moritz, Mark; Piperata, Barbara; Lee, Jiyoung
2016-06-01
This study examined the spatial variation of potential gastrointestinal pathogens within drinking water sources and home storage containers in four neighborhoods in Maroua, Cameroon. Samples were collected from source (n = 28) and home containers (n = 60) in each study neighborhood. Pathogen contamination was assessed using quantitative polymerase chain reaction, targeting Campylobacter spp., Shiga toxin producing Escherichia coli (virulence genes, stx1 and stx2), and Salmonella spp. Microbial source tracking (MST) targeted three different host-specific markers: HF183 (human), Rum2Bac (ruminant) and GFD (poultry) to identify contamination sources. Staphylococcus aureus and the tetracycline-resistance gene (tetQ) were assessed to measure human hand contact and presence of antibiotic-resistant bacteria. Pathogen/MST levels were compared statistically and spatially, and neighborhood variation was compared with previously collected demographic information. All the test fecal markers and pathogens (except Arcobacter) were detected in home and source samples. Two neighborhoods tested positive for most pathogens/MST while the others only tested positive for one or two. Spatial variation of pathogens/MST existed between sources, storage containers, and neighborhoods. Differing population density and ethno-economic characteristics could potentially explain variation. Future research should explore the influence of demographic and ethno-economic factors on water quality during microbial risk assessments in urban Africa.
Panahandeh, Narges; Torabzadeh, Hassan; Aghaee, Mohammadamin; Hasani, Elham; Safa, Saeed
2018-01-01
The aim of this study is to investigate the physical properties of conventional and resin-modified glass ionomer cements (GICs) compared to GICs supplemented with zinc oxide (ZnO) nanofiller particles at 5% (w/w). In this in vitro study, ZnO nanoparticles of different morphologies (nanospherical, nanorod, and nanoflower) were incorporated to glass ionomer powder. The samples were subjected to the flexural strength ( n = 20) and surface hardness test ( n = 12) using a universal testing machine and a Vickers hardness machine, respectively. Surface analysis and crystal structure of samples were performed with scanning electron microscope and X-radiation diffraction, respectively. The data were analyzed using one-way ANOVA, Shapiro-Wilk, and Tukey's tests ( P < 0.05). Flexural strength of glass ionomer containing nanoparticles was not significantly different from the control group ( P > 0.05). The surface hardness of the glass ionomer containing nanospherical or nanoflower ZnO was significantly lower than the control group ( P < 0.05). However, the surface hardness of glass ionomer containing nanorod ZnO was not significantly different from the control group ( P = 0.868). Incorporation of nanospherical and nanoflower ZnO to glass ionomer decreased their surface hardness, without any changes on their flexural strength. Incorporation of nanorod ZnO particles caused no effect on the mechanical properties.
Bacterial and fungal biofilm formation on anodized titanium alloys with fluorine.
Perez-Jorge, Concepcion; Arenas, Maria-Angeles; Conde, Ana; Hernández-Lopez, Juan-Manuel; de Damborenea, Juan-Jose; Fisher, Steve; Hunt, Alessandra M Agostinho; Esteban, Jaime; James, Garth
2017-01-01
Orthopaedic device-related infections are closely linked to biofilm formation on the surfaces of these devices. Several modified titanium (Ti-6Al-4V) surfaces doped with fluorine were studied in order to evaluate the influence of these modifications on biofilm formation by Gram-positive and Gram-negative bacteria as well as a yeast. The biofilm studies were performed according to the standard test method approved by ASTM (Designation: E2196-12) using the Rotating Disk Reactor. Four types of Ti-6Al-4V samples were tested; chemically polished (CP), two types of nanostructures containing fluorine, nanoporous (NP) and nanotubular (NT), and non-nanostructured fluorine containing samples (fluoride barrier layers, FBL). Different species of Gram-positive cocci, (Staphylococcus aureus and epidermidis), Gram-negative rods (Escherichia coli, Pseudomonas aeruginosa), and a yeast (Candida albicans) were studied. For one of the Gram-positive (S. epidermidis) and one of the Gram-negative (E. coli) species a statistically-significant decrease in biofilm accumulation for NP and NT samples was found when compared with the biofilm accumulation on CP samples. The results suggest an effect of the modified materials on the biofilm formation.
Ulca, P; Evcimen, M K; Senyuva, H Z
2010-01-01
Surveys were carried out between 2007 and 2009 to determine the aflatoxin B1 content of 3345 commercial Turkish foodstuffs supplied by producers for testing for their own purposes or for export certification. To simplify the reporting of data, foods were categorized as: 1, high sugar products with nuts; 2, nuts and seeds; 3, spices; 4, grain; 5, cocoa products; 6, dried fruit and vegetables; 7, processed cereal products; 8, tea; and 9, baby food and infant formula. Aflatoxin analysis was carried out by high-performance liquid chromatography with fluorescence detection after immunoaffinity column clean-up, with a recoveries ranging from 91% to 99%, depending on the matrix. Of the 3345 samples analysed, 94% contained aflatoxin B1 below the European Union limit of 2 µg kg(-1), which applies to nuts, dried fruit, and cereals products. The 6% of the 206 contaminated samples were mainly nuts and spices. For pistachios, 24%, 38%, and 42% of the totals of 207, 182, and 24 samples tested for 2007, 2008 and 2009, respectively, were above 2 µg kg(-1), with 50 samples containing aflatoxin B1 at levels ranging from 10 to 477 µg kg(-1).
Nagarajappa, Ramesh; Daryani, Hemasha; Sharda, Archana J; Asawa, Kailash; Batra, Mehak; Sanadhya, Sudhanshu; Ramesh, Gayathri
2015-01-01
To examine the effect of chocobar ice cream containing bifidobacteria on salivary mutans streptococci and lactobacilli. A double-blind, randomised controlled trial was conducted with 30 subjects (18 to 22 years of age) divided into 2 groups, test (chocobar ice cream with probiotics) and control (chocobar ice cream without probiotics). The subjects were instructed to eat the allotted chocobar ice cream once daily for 18 days. Saliva samples collected at intervals were cultured on Mitis Salivarius agar and Rogosa agar and examined for salivary mutans streptococci and lactobacilli, respectively. The Mann-Whitney U-test, Friedman and Wilcoxon signed-rank tests were used for statistical analysis. Postingestion in the test group, a statistically significant reduction (p < 0.05) of salivary mutans streptococci was recorded, but a non-significant trend was seen for lactobacilli. Significant differences were was also observed between follow-ups. Short-term daily ingestion of ice cream containing probiotic bifidobacteria may reduce salivary levels of mutans streptococci in young adults.
McKenna, S L B; Ritter, C; Dohoo, I; Keefe, G P; Barkema, H W
2018-05-23
In herds with typical moderate to low within-herd prevalence, testing for Mycobacterium avium ssp. paratuberculosis (MAP), the infectious agent of Johne's disease, will be more cost-effective if individual fecal samples are cultured in composite pools. However, sensitivity to classify a pool containing 1 or more positive individual samples as positive may depend on pool size and number of individual positive samples within a pool. Fecal samples collected from 994 dairy cows sampled at slaughter were cultured to detect MAP. Culturing was done both individually and as composite pooled samples using the TREK ESP Culture System II broth medium (Thermo Fisher Scientific, Trek Diagnostic Systems Inc., Cleveland, OH). Composite samples consisted of pools containing feces from 3, 5, 8, 10, or 15 cows. The number of individual fecal culture-positive cows within each pool ranged from 0 to 4. Culture of individual fecal samples detected MAP in 36 (3.6%) of the 994 cows. Individual samples that were detected within the first 50 d by TREK ESP Culture System II were more likely to lead to a positive pool result. In total, 840 pooled fecal samples were examined for presence of MAP, and of those, 272 pools actually contained feces from fecal culture-positive cows. The crude sensitivity (proportion of pools that contained at least 1 fecal-positive cow that tested positive) for pools of 3, 5, 8, 10, and 15 was 47, 67, 44, 59, and 39%, respectively. Across pools, an increase of the number of fecal culture-positive samples from 1 to 2 enhanced overall crude sensitivity from 44 to 71%. However, sensitivity did not further increase for pools with 3 or 4 fecal culture-positive samples (63 and 60%, respectively). Additionally, a simulation analysis assessing probability of pooled fecal samples being positive in herds of 50 and 100 cows was conducted. The simulation assumed that 1, 2, or 5 cows per herd were MAP fecal culture-positive and that pools of 5 and 10 were used. This low-prevalence herd simulation indicated that weighted mean herd probabilities of detecting a positive herd ranged between 52 and 99.3%, with the lowest probability for pools of 10 with 1 positive cow in the herd and the highest probability for pools of 5 with 5 positive cows in the herd. However, overall, pools of 5 and 10 had similar diagnostic capabilities, enabling cost savings by utilizing pools of 10. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
1999-09-01
Harrington , showed that with respect to mixed water analysis containing TDS at greater 1,000 ppm, the performance of the AS-5 column is not as robust...to note, these raw test materials were heterogeneous. Regardless of mixing time and mesh quality, dividing the raw test materials for laboratory...raw test material was prepared and shipped to seven laboratories for blind analysis. The suspension was prepared by 4 mixing the solid sample with
A HUPO test sample study reveals common problems in mass spectrometry-based proteomics
Bell, Alexander W.; Deutsch, Eric W.; Au, Catherine E.; Kearney, Robert E.; Beavis, Ron; Sechi, Salvatore; Nilsson, Tommy; Bergeron, John J.M.
2009-01-01
We carried out a test sample study to try to identify errors leading to irreproducibility, including incompleteness of peptide sampling, in LC-MS-based proteomics. We distributed a test sample consisting of an equimolar mix of 20 highly purified recombinant human proteins, to 27 laboratories for identification. Each protein contained one or more unique tryptic peptides of 1250 Da to also test for ion selection and sampling in the mass spectrometer. Of the 27 labs, initially only 7 labs reported all 20 proteins correctly, and only 1 lab reported all the tryptic peptides of 1250 Da. Nevertheless, a subsequent centralized analysis of the raw data revealed that all 20 proteins and most of the 1250 Da peptides had in fact been detected by all 27 labs. The centralized analysis allowed us to determine sources of problems encountered in the study, which include missed identifications (false negatives), environmental contamination, database matching, and curation of protein identifications. Improved search engines and databases are likely to increase the fidelity of mass spectrometry-based proteomics. PMID:19448641
Chow, Judith C; Watson, John G; Robles, Jerome; Wang, Xiaoliang; Chen, L-W Antony; Trimble, Dana L; Kohl, Steven D; Tropp, Richard J; Fung, Kochy K
2011-12-01
Accurate, precise, and valid organic and elemental carbon (OC and EC, respectively) measurements require more effort than the routine analysis of ambient aerosol and source samples. This paper documents the quality assurance (QA) and quality control (QC) procedures that should be implemented to ensure consistency of OC and EC measurements. Prior to field sampling, the appropriate filter substrate must be selected and tested for sampling effectiveness. Unexposed filters are pre-fired to remove contaminants and acceptance tested. After sampling, filters must be stored in the laboratory in clean, labeled containers under refrigeration (<4 °C) to minimize loss of semi-volatile OC. QA activities include participation in laboratory accreditation programs, external system audits, and interlaboratory comparisons. For thermal/optical carbon analyses, periodic QC tests include calibration of the flame ionization detector with different types of carbon standards, thermogram inspection, replicate analyses, quantification of trace oxygen concentrations (<100 ppmv) in the helium atmosphere, and calibration of the sample temperature sensor. These established QA/QC procedures are applicable to aerosol sampling and analysis for carbon and other chemical components.
Tondare, Vipin N; Villarrubia, John S; Vlada R, András E
2017-10-01
Three-dimensional (3D) reconstruction of a sample surface from scanning electron microscope (SEM) images taken at two perspectives has been known for decades. Nowadays, there exist several commercially available stereophotogrammetry software packages. For testing these software packages, in this study we used Monte Carlo simulated SEM images of virtual samples. A virtual sample is a model in a computer, and its true dimensions are known exactly, which is impossible for real SEM samples due to measurement uncertainty. The simulated SEM images can be used for algorithm testing, development, and validation. We tested two stereophotogrammetry software packages and compared their reconstructed 3D models with the known geometry of the virtual samples used to create the simulated SEM images. Both packages performed relatively well with simulated SEM images of a sample with a rough surface. However, in a sample containing nearly uniform and therefore low-contrast zones, the height reconstruction error was ≈46%. The present stereophotogrammetry software packages need further improvement before they can be used reliably with SEM images with uniform zones.
Level and Chemical Composition of Cryoglobulins in Schizophrenia
NASA Astrophysics Data System (ADS)
Khoyetsyan, Aren; Boyajyan, Anna; Melkumova, Maya
The blood samples of 40 schizophrenic patients were tested for the presence of cryoglobulins (Cgs) and composition of Cgs was examined. The elevated levels of type III Cgs, containing complement components, were detected in all study subjects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
De Lucia, Frank C. Jr.; Gottfried, Jennifer L.; Munson, Chase A.
2008-11-01
A technique being evaluated for standoff explosives detection is laser-induced breakdown spectroscopy (LIBS). LIBS is a real-time sensor technology that uses components that can be configured into a ruggedized standoff instrument. The U.S. Army Research Laboratory has been coupling standoff LIBS spectra with chemometrics for several years now in order to discriminate between explosives and nonexplosives. We have investigated the use of partial least squares discriminant analysis (PLS-DA) for explosives detection. We have extended our study of PLS-DA to more complex sample types, including binary mixtures, different types of explosives, and samples not included in the model. We demonstrate themore » importance of building the PLS-DA model by iteratively testing it against sample test sets. Independent test sets are used to test the robustness of the final model.« less
NASA Astrophysics Data System (ADS)
Bello Yamusa, Yamusa; Yunus, Nor Zurairahetty Mohd; Ahmad, Kamarudin; Rahman, Norhan Abd; Sa'ari, Radzuan
2018-03-01
Laterite soil was investigated to find out the effects of fines content and to identify the micro-structural and molecular characteristics to evaluate its potentiality as a compacted soil landfill liner material. Tests were carried out on natural soil and reconstituted soil by dry weight of soil samples to determine the physical and engineering properties of the soil. All tests were carried out on the samples by adopting the British Standard 1377:1990. The possible mechanisms that contributed to the clay mineralogy were analyzed using spectroscopic and microscopic techniques such as field emission scanning electron microscopy (FESEM), energy-dispersive X-ray (EDX) and X-ray diffractometry (XRD). The laterite soil was found to contain kaolinite as the major clay minerals. A minimum of 50% fines content of laterite soil met the required result for hydraulic barriers in waste containment facilities.
An Investigation of Tendon Corrosion-Inhibitor Leakage into Concrete
DOE Office of Scientific and Technical Information (OSTI.GOV)
Costello, J.F.; Naus, D.J.; Oland, C.B.
1999-07-05
During inspections performed at US nuclear power plants several years ago, some of the prestressed concrete containment had experienced leakage of the tendon sheathing filler. A study was conducted to indicate the extent of the leakage into the concrete and its potential effects on concrete properties. Concrete core samples were obtained from the Trojan Nuclear Plant. Examination and testing of the core samples indicated that the appearance of tendon sheathing filler on the surface was due to leakage of the filler from the conduits and its subsequent migration to the concrete surface through cracks that were present. Migration of themore » tendon sheathing filler was confined to the cracks with no perceptible movement into the concrete. Results of compressive strength tests indicated that the concrete quality was consistent in the containment and that the strength had increased relative to the strength at 28 days age.« less
Kawakami, Tsuyoshi; Isama, Kazuo; Nakashima, Harunobu; Yoshida, Jin; Ooshima, Tomoko; Ohno, Hiroyuki; Uemura, Hitoshi; Shioda, Hiroko; Kikuchi, Yoko; Matsuoka, Atsuko; Nishimura, Tetsuji
2012-01-01
The use of triphenyltin (TPT) and tributyltin (TBT) in some household products is banned by "Act on the Control of Household Products Containing Harmful Substances" in Japan. To revise the official analytical method, the method for detecting these organotin compounds was examined in six laboratories using a textile product, water-based adhesive, oil-based paint, which contained known amounts of TPT and TBT (0.1, 1.0, 10 μg/g). TPT and TBT were measured by GC-MS after ethyl-derivation with sodium tetraethylborate. The TBT recoveries in the samples were 70-120%. The TPT recoveries in the water-based adhesive samples were 80-110%, while its concentrations in the textile product and oil-based paint samples decreased because of dephenylation during storage. However, the precision of the method examined was satisfactory because most coefficients of variation for TPT and TBT in the samples were less than 10%. Furthermore, the revised method was able to detect concentrations lower than the officially regulated value. However, the sample matrix and the condition of analytical instrument might affect the estimated TPT and TBT concentrations. Therefore, the revised method may not be suitable for quantitative tests; rather, it can be employed to judge the acceptable levels of these organotin compounds by comparing the values of control sample containing regulated amounts of TPT and TBT with those for an unknown sample, with deuterated TPT and TBT as surrogate substances. It is desirable that TPT in textile and oil-based paint samples are analyzed immediately after the samples obtained because of the decomposition of TPT.
A portable molecular-sieve-based CO{sub 2} sampling system for radiocarbon measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palonen, V., E-mail: vesa.palonen@helsinki.fi
We have developed a field-capable sampling system for the collection of CO{sub 2} samples for radiocarbon-concentration measurements. Most target systems in environmental research are limited in volume and CO{sub 2} concentration, making conventional flask sampling hard or impossible for radiocarbon studies. The present system captures the CO{sub 2} selectively to cartridges containing 13X molecular sieve material. The sampling does not introduce significant under-pressures or significant losses of moisture to the target system, making it suitable for most environmental targets. The system also incorporates a significantly larger sieve container for the removal of CO{sub 2} from chambers prior to the CO{submore » 2} build-up phase and sampling. In addition, both the CO{sub 2} and H{sub 2}O content of the sample gas are measured continuously. This enables in situ estimation of the amount of collected CO{sub 2} and the determination of CO{sub 2} flux to a chamber. The portable sampling system is described in detail and tests for the reliability of the method are presented.« less
Microbiological test results using three urine pretreatment regimes with 316L stainless steel
NASA Technical Reports Server (NTRS)
Huff, Timothy L.
1993-01-01
Three urine pretreatments, (1) Oxone (Dupont) and sulfuric acid, (2) sodium hypochlorite and sulfuric acid, (3) and ozone, were studied for their ability to reduce microbial levels in urine and minimize surface attachment to 316L stainless steel coupons. Urine samples inoculated with Bacillus insolitus and a filamentous mold, organisms previously recovered from the vapor compression distillation subsystem of NASA Space Station Freedom water recovery test were tested in glass corrosion cells containing base or weld metal coupons. Microbial levels, changes in pH, color, turbidity, and odor of the fluid were monitored over the course of the 21-day test. Specimen surfaces were examined by scanning electron microscopy at completion of the test for microbial attachment. Ozonated urine samples were less turbid and had lower microbial levels than controls or samples receiving other pretreatments. Base metal coupons receiving pretreatment were relatively free of attached bacteria. However, well-developed biofilms were found in the heat-affected regions of welded coupons receiving Oxone and hypochlorite pretreatments. Few bacteria were observed in the same regions of the ozone pretreatment sample.
CTP (Cochlin-tomoprotein) detection in the profuse fluid leakage (gusher) from cochleostomy.
Ikezono, Tetsuo; Sugizaki, Kazuki; Shindo, Susumu; Sekiguchi, Satomi; Pawankar, Ruby; Baba, Shunkichi; Yagi, Toshiaki
2010-08-01
By testing 125 samples, we confirmed that Cochlin-tomoprotein (CTP) is present in the perilymph, not in cerebrospinal fluid (CSF). Perilymph and CSF exist in two distinct compartments, even in the case of a malformed inner ear with a bony defect in the lamina cribrosa, as described here. Cochleostomy might have suddenly decreased the perilymph pressure, allowing the influx of CSF into the inner ear resulting in profuse fluid leakage, first perilymph then CSF. The first purpose of this study was to further confirm the specificity of the perilymph-specific protein CTP that we reported recently. Secondly, we assessed the nature of the fluid leakage from the cochleostomy using the CTP detection test. A standardized CTP detection test was performed on 65 perilymph and 60 CSF samples. Samples of profuse fluid leakage collected from cochleostomy during cochlear implantation surgery of one patient with branchio-oto-renal (BOR) syndrome were also tested by the CTP detection test. CTP was detected in 60 of 65 perilymph samples but not in any of the CSF samples. The leaked fluid was shown to contain CTP, i.e. perilymph, at the outset, and then the CTP detection signals gradually disappeared as time elapsed.
Performance of a New HPV Cervi-Collect Collection and Transportation Kit
Chernesky, M.; Huang, S.; Jang, D.; Erickson, B.; Salituro, J.; Engel, H.; Gilchrist, J.; Neuscheler, P.; Mak, W. B.; Abravaya, K.
2012-01-01
Background. Liquid-based Pap (L-Pap) media are used for Pap and human papillomavirus (HPV) testing. Objectives. To compare RealTime High Risk (HR) HPV testing of a new collection kit (Cervi-Collect) and PreservCyt L-Pap specimens. To determine ease of use and safety of Cervi-Collect. Methods. L-Pap samples (n = 203) were tested with HC2 and RealTime HR HPV and Cervi-Collect with RealTime HR HPV. Discordant samples were genotyped. Results. L-Pap and Cervi-Collect specimens tested by RealTime HR HPV showed 93.1% agreement (Kappa 0.86). RealTime HR HPV and HC2 on L-Pap had 90.3% agreement (Kappa 0.80). RealTime HR HPV on Cervi-Collect and HC2 on L-Pap showed 88.2% agreement (Kappa 0.76). Sixteen of 21 samples which were HC2 negative and RealTime HR HPV positive on L-Pap or Cervi-Collect contained HR HPV genotypes. Eleven healthcare collectors were in strong agreement on a usability and safety questionnaire. Conclusion. Cervi-Collect samples were easy to collect and showed strong agreement with L-Pap samples tested with RealTime HR HPV or HC2. PMID:22174716
Applicability of canisters for sample storage in the determination of hazardous air pollutants
NASA Astrophysics Data System (ADS)
Kelly, Thomas J.; Holdren, Michael W.
This paper evaluates the applicability of canisters for storage of air samples containing volatile organic compounds listed among the 189 hazardous air pollutants (HAPs) in the 1990 U.S. Clean Air Act Amendments. Nearly 100 HAPs have sufficient vapor pressure to be considered volatile compounds. Of those volatile organic HAPs, 52 have been tested previously for stability during storage in canisters. The published HAP stability studies are reviewed, illustrating that for most of the 52 HAPs tested, canisters are an effective sample storage approach. However, the published stability studies used a variety of canister types and test procedures, and generally considered only a few compounds in a very small set of canisters. A comparison of chemical and physical properties of the HAPs has also been conducted, to evaluate the applicability of canister sampling for other HAPs, for which canister stability testing has never been conducted. Of 45 volatile HAPs never tested in canisters, this comparison identifies nine for which canisters should be effective, and 17 for which canisters are not likely to be effective. For the other 19 HAPs, no clear decision can be reached on the likely applicability of air sample storage in canisters.
Li, Ming-yu; Wang, Jun; Xu, Zhu-ting
2010-01-01
Background: The principal components of halitosis are volatile sulfur compounds (VSCs) such as hydrogen sulfide, methyl mercaptan, and dimethylsulfide or compounds such as butyric acid, propionic acid, putrescine, and cadaverine. Objective: The aim of this study was to evaluate the effect of Chinese herbs on VSCs in vitro. Methods: Saliva samples from volunteers were used as the source for the evaluation of bacterial activity and VSC inhibition. Extracted substances from Chinese herbs were identified by VSC inhibition tests with a Halimeter and microbial sensitivity testing. The effectiveness on halitosis was compared between a dentifrice containing one of the effective Chinese herbs (ie, chrysanthemum flower [Chrysanthemum morifolium flos]), 4 commercially available antihalitosis dentifrices, and a positive control that received no treatment. Results: Ten volunteers provided saliva samples for VSC testing. Of the 40 herbs tested, 14 extracts had percent inhibition rates of VSCs >50%. Ten herbs showed greatest effect against all culturable microorganisms with bacterial inhibition >70%. There was a weak positive correlation between bacteriostasis and the anti-VSC activity of the herbs with a correlation coefficient of 0.2579 (Pearson). The mean (SD) values of the VSC testing were as follows: dentifrice containing chrysanthemum flower, 55.91 (8.16) ppb; Crest Tea Refreshing Dentifrice®, 48.39 (7.48) ppb (P = NS); Cortex Phellodendri Dentifrice®, 139.90 (14.70) ppb (P < 0.01); Colgate Total Plus Whitening®, 120.94 (15.58) ppb (P < 0.01); Zhong Hua Chinese Herbs Dentifrice®, 136.96 (13.06) ppb (P < 0.01); and positive control, 312.38 (28.58) ppb (P < 0.01). Conclusions: Of 40 herbs tested, 14 Chinese herbs were found to be effective for VSC inhibition. A dentifrice containing chrysanthemum flower reduced the formation of VSC in vitro, showing a significantly greater effect than the control group and 3 of 4 dentifrices already on the market. PMID:24683259
Li, Ming-Yu; Wang, Jun; Xu, Zhu-Ting
2010-04-01
The principal components of halitosis are volatile sulfur compounds (VSCs) such as hydrogen sulfide, methyl mercaptan, and dimethylsulfide or compounds such as butyric acid, propionic acid, putrescine, and cadaverine. The aim of this study was to evaluate the effect of Chinese herbs on VSCs in vitro. Saliva samples from volunteers were used as the source for the evaluation of bacterial activity and VSC inhibition. Extracted substances from Chinese herbs were identified by VSC inhibition tests with a Halimeter and microbial sensitivity testing. The effectiveness on halitosis was compared between a dentifrice containing one of the effective Chinese herbs (ie, chrysanthemum flower [Chrysanthemum morifolium flos]), 4 commercially available antihalitosis dentifrices, and a positive control that received no treatment. Ten volunteers provided saliva samples for VSC testing. Of the 40 herbs tested, 14 extracts had percent inhibition rates of VSCs >50%. Ten herbs showed greatest effect against all culturable microorganisms with bacterial inhibition >70%. There was a weak positive correlation between bacteriostasis and the anti-VSC activity of the herbs with a correlation coefficient of 0.2579 (Pearson). The mean (SD) values of the VSC testing were as follows: dentifrice containing chrysanthemum flower, 55.91 (8.16) ppb; Crest Tea Refreshing Dentifrice®, 48.39 (7.48) ppb (P = NS); Cortex Phellodendri Dentifrice®, 139.90 (14.70) ppb (P < 0.01); Colgate Total Plus Whitening®, 120.94 (15.58) ppb (P < 0.01); Zhong Hua Chinese Herbs Dentifrice®, 136.96 (13.06) ppb (P < 0.01); and positive control, 312.38 (28.58) ppb (P < 0.01). Of 40 herbs tested, 14 Chinese herbs were found to be effective for VSC inhibition. A dentifrice containing chrysanthemum flower reduced the formation of VSC in vitro, showing a significantly greater effect than the control group and 3 of 4 dentifrices already on the market.
Mohanty, Pritam; Padmanabhan, Sridevi; Chitharanjan, Arun B
2014-11-01
To evaluate and compare the Ca/P ratio of enamel samples around the orthodontic brackets for time periods of 0, 2 and 10 days in two groups (control group and study group). Forty extracted teeth were randomly divided into control group and study group. All samples were demineralized and incubated in artificial saliva at 37°C for a period of 10 days after demineralization. During this phase the enamel samples in the study group were treated with remineralizing paste (NuproNusolution containing Novamin®-Dentsply) for 10 days. At the end of the incubation period, Ca/P ratios were analyzed for both the groupsby EDX analysis. Data obtained was subjected to statistical analysis using student t-test for paired samples and Student t- test for individual samples (p ≤ 0.05). It was found that the mean Ca/P ratio was significantly lower for the control group as compared to the study group (p-value < 0.05) after 10 d of incubation. Novamin(®) containing remineralization toothpaste showed significant remineralizing potential in inhibition of artificial enamel sub-surface lesion around bracket after 10 days of remineralization phase. EDX element analysis was found to be an efficient method to quantify the changes in mineral content of a sample during in vitro caries studies.
Padmanabhan, Sridevi; Chitharanjan, Arun B
2014-01-01
Objective: To evaluate and compare the Ca/P ratio of enamel samples around the orthodontic brackets for time periods of 0, 2 and 10 days in two groups (control group and study group). Materials and Methods: Forty extracted teeth were randomly divided into control group and study group. All samples were demineralized and incubated in artificial saliva at 37°C for a period of 10 days after demineralization. During this phase the enamel samples in the study group were treated with remineralizing paste (NuproNusolution containing Novamin®-Dentsply) for 10 days. At the end of the incubation period, Ca/P ratios were analyzed for both the groupsby EDX analysis. Data obtained was subjected to statistical analysis using student t-test for paired samples and Student t- test for individual samples (p ≤ 0.05). Results: It was found that the mean Ca/P ratio was significantly lower for the control group as compared to the study group (p-value < 0.05) after 10 d of incubation. Conclusion: Novamin® containing remineralization toothpaste showed significant remineralizing potential in inhibition of artificial enamel sub-surface lesion around bracket after 10 days of remineralization phase. EDX element analysis was found to be an efficient method to quantify the changes in mineral content of a sample during in vitro caries studies. PMID:25584326
Katakweba, Abdul A S; Muhairwa, Amandus P; Lupindu, Athumani M; Damborg, Peter; Rosenkrantz, Jesper T; Minga, Uswege M; Mtambo, Madundo M A; Olsen, John E
2018-04-01
This study provides an estimate of antimicrobial resistance in intestinal indicator bacteria from humans (n = 97) and food animals (n = 388) in Tanzania. More than 70% of all fecal samples contained tetracycline (TE), sulfamethoxazole (STX), and ampicillin (AMP)-resistant coliforms, while cefotaxime (CTX)-resistant coliforms were observed in 40% of all samples. The average Log 10 colony forming units/g of CTX-resistant coliforms in samples from humans were 2.20. Of 390 Escherichia coli tested, 66.4% were resistant to TE, 54.9% to STX, 54.9% to streptomycin, and 36.4% to CTX. Isolates were commonly (65.1%) multiresistant. All CTX-resistant isolates contained bla CTX-M gene type. AMP- and vancomycin-resistant enterococci were rare, and the average concentrations in positive samples were low (log 10 0.9 and 0.4, respectively). A low-to-moderate resistance (2.1-15%) was detected in 240 enterococci isolates to the drugs tested, except for rifampicin resistance (75.2% of isolates). The average number of sulII gene copies varied between Log 10 5.37 and 5.68 with no significant difference between sample source, while cattle had significantly higher number of tetW genes than humans. These findings, based on randomly obtained samples, will be instrumental in designing antimicrobial resistance (AMR) intervention strategies for Tanzania.
Automated collection and processing of environmental samples
Troyer, Gary L.; McNeece, Susan G.; Brayton, Darryl D.; Panesar, Amardip K.
1997-01-01
For monitoring an environmental parameter such as the level of nuclear radiation, at distributed sites, bar coded sample collectors are deployed and their codes are read using a portable data entry unit that also records the time of deployment. The time and collector identity are cross referenced in memory in the portable unit. Similarly, when later recovering the collector for testing, the code is again read and the time of collection is stored as indexed to the sample collector, or to a further bar code, for example as provided on a container for the sample. The identity of the operator can also be encoded and stored. After deploying and/or recovering the sample collectors, the data is transmitted to a base processor. The samples are tested, preferably using a test unit coupled to the base processor, and again the time is recorded. The base processor computes the level of radiation at the site during exposure of the sample collector, using the detected radiation level of the sample, the delay between recovery and testing, the duration of exposure and the half life of the isotopes collected. In one embodiment, an identity code and a site code are optically read by an image grabber coupled to the portable data entry unit.
Leaching assessment of road materials containing primary lead and zinc slags.
Barna, R; Moszkowicz, P; Gervais, C
2004-01-01
Characterisation of the leaching behaviour of waste-containing materials is a crucial step in the environmental assessment for reuse scenarios. In our research we applied the multi-step European methodology ENV 12-920 to the leaching assessment of road materials containing metallurgical slag. A Zn slag from an imperial smelting furnace (ISF) and a Pb slag from a lead blast furnace (LBF) are investigated. The two slags contain up to 11.2 wt% of lead and 3.5 wt% of zinc and were introduced as a partial substitute for sand in two road materials, namely sand-cement and sand-bitumen. At the laboratory scale, a leaching assessment was performed first through batch equilibrium leaching tests. Second, the release rate of the contaminants was evaluated using saturated leaching tests on monolithic material. Third, laboratory tests were conducted on monolithic samples under intermittent wetting conditions. Pilot-scale tests were conducted for field testing of intermittent wetting conditions. The results show that the release of Pb and Zn from the materials in a saturated scenario was controlled by the pH of the leachates. For the intermittent wetting conditions, an additional factor, blocking of the pores by precipitation during the drying phase is proposed. Pilot-scale leaching behaviour only partially matched with the laboratory-scale test results: new mass transfer mechanisms and adapted laboratory leaching tests are discussed.
3013 DE INNER CONTAINER CLOSURE WELD CORROSION EVALUATION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mickalonis, J.
Destructive evaluation (DE) of 3013 containers is one part of the U. S. Department of Energy Integrated Surveillance Program. During standard DE of 3013 containers, visual examinations for pitting and stress corrosion cracking (SCC) are performed on the accessible surfaces of the outer, inner, and convenience containers, which make up the 3013 container. As a result of 3013 DE additional analysis, the area near the inner container closure weld has been identified as being a region of increased corrosion susceptibility, which may provide a pathway for corrosive gases to the outer container. This area has a higher residual stress, anmore » altered microstructure, and less corrosion resistant weld oxides as a result of the welding process as well as a lower temperature than other areas of the container, which may increase the absorption of moisture on the surface. The deposition of moisture in this stressed region could lead to pitting and stress corrosion cracking. During FY2013, the inner container closure weld area was more closely evaluated on several archived samples from DE containers. These containers included FY09 DE2, FY12 DE4, FY12 DE6 and FY12 DE7 and the Hanford High Moisture Container. The additional examinations included visual observations with a stereomicroscope, scanning electron microscopy along with energy dispersive spectroscopy for chemical analysis, and serial metallography of the sidewall and lid that are part of the inner container closure weld region. Pitting was observed in all the samples taken from the closure weld regions of the examined inner containers. This pitting was generally less 20 μm with most less than 5m. These pits were similar in depth to those observed in the vapor exposed surfaces of teardrops in the shelf life corrosion testing. Cracking was not observed on either the vapor-exposed surfaces of the teardrop coupons or the inner container closure weld region. Further testing is necessary to determine if the conditions in the welded inner container could support SCC during the 50 year life time for the 3013 container.« less
Albumin adsorption onto surfaces of urine collection and analysis containers.
Robinson, Mary K; Caudill, Samuel P; Koch, David D; Ritchie, James; Hortin, Glen; Eckfeldt, John H; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W Greg
2014-04-20
Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. We added (125)I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Adsorption of urine albumin (UA) at 5-6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH8 than pH5 but only 3 cases had p<0.05. Adsorption from 11 unaltered urine samples with albumin 5-333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2-28%) was larger than that from urine. Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. Copyright © 2014 Elsevier B.V. All rights reserved.
Exfiltrometer apparatus and method for measuring unsaturated hydrologic properties in soil
Hubbell, Joel M.; Sisson, James B.; Schafer, Annette L.
2006-01-17
Exfiltrometer apparatus includes a container for holding soil. A sample container for holding sample soil is positionable with respect to the container so that the sample soil contained in the sample container is in communication with soil contained in the container. A first tensiometer operatively associated with the sample container senses a surface water potential at about a surface of the sample soil contained in the sample container. A second tensiometer operatively associated with the sample container senses a first subsurface water potential below the surface of the sample soil. A water content sensor operatively associated with the sample container senses a water content in the sample soil. A water supply supplies water to the sample soil. A data logger operatively connected to the first and second tensiometers, and to the water content sensor receives and processes data provided by the first and second tensiometers and by the water content sensor.
Markovich, Jessica E; Stucker, Karla M; Carr, Alaina H; Harbison, Carole E; Scarlett, Janet M; Parrish, Colin R
2012-07-01
To estimate the prevalence of canine parvovirus (CPV) strains among dogs with enteritis admitted to a referral hospital in the southwestern United States during an 11-month period and to compare diagnostic test results, disease severity, and patient outcome among CPV strains. Prospective observational study. 72 dogs with histories and clinical signs of parvoviral enteritis. For each dog, a fecal sample or rectal swab specimen was evaluated for CPV antigen via an ELISA. Subsequently, fecal samples (n = 42 dogs) and pharyngeal swab specimens (16) were obtained and tested for CPV antigen via an ELISA and CPV DNA via a PCR assay. For specimens with CPV-positive results via PCR assay, genetic sequencing was performed to identify the CPV strain. 56 dogs tested positive for CPV via ELISA or PCR assay. For 42 fecal samples tested via both ELISA and PCR assay, 27 had positive results via both assays, whereas 6 had positive PCR assay results only. Ten pharyngeal swab specimens yielded positive PCR assay results. Genetic sequencing was performed on 34 fecal or pharyngeal swab specimens that had CPV-positive PCR assay results; 25 (73.5%) were identified as containing CPV type-2c, and 9 (26.5%) were identified as containing CPV type-2b. No association was found between CPV strain and disease severity or clinical outcome. CPV type-2b and CPV type-2c posed similar health risks for dogs; therefore, genetic sequencing of CPV does not appear necessary for clinical management of infected patients. The diagnostic tests used could detect CPV type-2c.
Development of a method which discriminates between endogenous and exogenous beta-boldenone.
Blokland, M H; van Rossum, H J; Sterk, S S; van Ginkel, L A; Stephany, R W
2007-03-14
One potential explanation for the presence of beta-boldenone in calf urine is contamination of the sample with feces containing beta-boldenone. It has been demonstrated that after oral and intramuscular administration of beta-boldenone esters, several metabolites are formed and excreted in urine. One of the (minor) metabolites is 6beta-hydroxy-17alpha-boldenone. This paper describes an analytical method that can discriminate between unconjugated boldenone, its glucuronide- and sulphate-conjugates, 6beta-hydroxy-17alpha/beta-boldenone and coprostanol, a marker for fecal contamination. The method was applied to all samples suspected to contain boldenone within the Dutch National Residue Control Plan. Approximately 10,000 samples of urine were screened (LC-MS) in 2004-2005 by VWA-East, one of the official Dutch control laboratories, from which 261 samples were suspected to contain boldenone. These samples were all analyzed for their conjugation state, 6beta-hydroxy-17alpha/beta-boldenone and for the presence of coprostanol. Alfa-boldenone, the major metabolite in bovine urine after boldenone-ester administration, was found in a large number of these samples. The presence of alpha-boldenone was proven also to be a result of fecal contamination. None of the samples tested contained residues of the metabolite 6beta-hydroxy-17alpha/beta-boldenone. Not finding this metabolite indicates that the origin of alpha-boldenone-conjugates is endogenous. The results confirm that the presence of unconjugated beta-boldenone and alpha-boldenone conjugates next to alpha-boldenone are no indicators for illegal administration of boldenone-esters. No indications were obtained that conjugated beta-boldenone can be of endogenous origin.
NASA Astrophysics Data System (ADS)
Schulte, Wolfgang; Thiele, Hans; Hofmann, Peter; Baglioni, Pietro
The ExoMars program will search for past and present life on Mars. ExoMars will address important scientific goals and demonstrate key in-situ enabling technologies. Among such technologies are the acquisition, preparation, distribution and analysis of samples from Mars surface rocks and from the subsurface. The 2018 mission will land an ESA rover on Mars which carries a sample preparation and distribution system (SPDS) and a suite of analytical instruments, the Pasteur Payload with its Analytical Laboratory Drawer (ALD). Kayser-Threde GmbH (Germany) will be responsible for the SPDS as a subcontractor under the mission prime Thales Alenia Space. The SPDS comprises a number of complex mechanisms and mechanical devices designed to transport drill core samples within the rover analytical laboratory, to crush them to powder with a fine grain size, to portion discrete amounts of powdered sample material, to distribute and fill the material into sample containers and to prepare flat sample surfaces for scientific analysis. Breadboards of the crushing mechanism, the dosing mechanism and a distribution carousel with sample containers and a powder sample surface flattening mechanism were built and tested. Kayser-Threde, as a member of the Spanish led ExoMars Raman Instrument team, is also responsible for development of the Raman optical head, which will be mounted inside ALD and will inspect the crushed samples, when they are presented to the instrument by the distribution carousel. Within this activity, which is performed under contract with the Institute of Physical Chemistry of the University of Jena (Germany) and funded by the German DLR, Kayser-Threde can demonstrate Raman measurements with the optical head and a COTS laser and spectrometer and thus simulate the full Raman instrument optical path. An autofocus system with actuator and feedback optics is also part of this activity, which allows focusing the 50 m Raman spot on the surface of the powdered sample. Availability of both, the SPDS mechanisms and the Raman Spectrometer optical head at Kayser-Threde facilities allowed to demonstrate for the first time a sample preparation chain with a joint operation of the optical head. Mineral samples were crushed, dosed into sample containers on the carousel, flattened and then inspected by the Raman optical head. The samples were provided by the University of Jena, a member of the ExoMars Raman science team. This paper will give an overview of the breadboards developed so far for the ExoMars SPDS and the Raman optical head and illustrate the joint demonstration test setup of the SPDS with the instrument. The different behavior of different sample materials will be highlighted and first conclusions will be drawn on what could be learned from test setups combining the ExoMars SPDS and analytical instruments.
Akinboro, Akeem; Mohammed, Kamaruzaman; Rathnasamy, Selestin; Muniandy, Vijay Raj
2011-01-01
Unwanted side effects from a polluted water body may not be limited to the flora and fauna, they may also be transferred to the organisms along the food chain. Four water samples collected immediately and five days after rainfall from two locations inside the polluted Sungai Dua River (SGD) were tested for toxicity using the Allium cepa assay. The samples were analysed for metal content and were both macroscopically and microscopically evaluated. The water samples contained more sodium (Na+) and calcium (Ca2+) than the control tap water, and they showed root growth and mitotic inhibitions (MI) in A. cepa. However, the inhibitory effects were not dose-dependent. No chromosomal aberration (CA) was induced at 100.00% (undiluted water sample). These results suggest the water samples from SGD had weak mitodepressive and genotoxic effects on the A. cepa cells. PMID:24575215
Eigenhuis, Annemarie; Kamphuis, Jan H; Noordhof, Arjen
2017-09-01
A growing body of research suggests that the same general dimensions can describe normal and pathological personality, but most of the supporting evidence is exploratory. We aim to determine in a confirmatory framework the extent to which responses on the Multidimensional Personality Questionnaire (MPQ) are identical across general and clinical samples. We tested the Dutch brief form of the MPQ (MPQ-BF-NL) for measurement invariance across a general population subsample (N = 365) and a clinical sample (N = 365), using Multiple Group Confirmatory Factor Analysis (MGCFA) and Multiple Group Exploratory Structural Equation Modeling (MGESEM). As an omnibus personality test, the MPQ-BF-NL revealed strict invariance, indicating absence of bias. Unidimensional per scale tests for measurement invariance revealed that 10% of items appeared to contain bias across samples. Item bias only affected the scale interpretation of Achievement, with individuals from the clinical sample more readily admitting to put high demands on themselves than individuals from the general sample, regardless of trait level. This formal test of equivalence provides strong evidence for the common structure of normal and pathological personality and lends further support to the clinical utility of the MPQ. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gillespie, B.M.; Stromatt, R.W.; Ross, G.A.
This data package contains the results obtained by Pacific Northwest Laboratory (PNL) staff in the characterization of samples for the 101-SY Hydrogen Safety Project. The samples were submitted for analysis by Westinghouse Hanford Company (WHC) under the Technical Project Plan (TPP) 17667 and the Quality Assurance Plan MCS-027. They came from a core taken during Window C'' after the May 1991 gas release event. The analytical procedures required for analysis were defined in the Test Instructions (TI) prepared by the PNL 101-SY Analytical Chemistry Laboratory (ACL) Project Management Office in accordance with the TPP and the QA Plan. The requestedmore » analysis for these samples was volatile organic analysis. The quality control (QC) requirements for each sample are defined in the Test Instructions for each sample. The QC requirements outlined in the procedures and requested in the WHC statement of work were followed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gillespie, B.M.; Stromatt, R.W.; Ross, G.A.
This data package contains the results obtained by Pacific Northwest Laboratory (PNL) staff in the characterization of samples for the 101-SY Hydrogen Safety Project. The samples were submitted for analysis by Westinghouse Hanford Company (WHC) under the Technical Project Plan (TPP) 17667 and the Quality Assurance Plan MCS-027. They came from a core taken during Window ``C`` after the May 1991 gas release event. The analytical procedures required for analysis were defined in the Test Instructions (TI) prepared by the PNL 101-SY Analytical Chemistry Laboratory (ACL) Project Management Office in accordance with the TPP and the QA Plan. The requestedmore » analysis for these samples was volatile organic analysis. The quality control (QC) requirements for each sample are defined in the Test Instructions for each sample. The QC requirements outlined in the procedures and requested in the WHC statement of work were followed.« less
Lunar Samples: Apollo Collection Tools, Curation Handling, Surveyor III and Soviet Luna Samples
NASA Technical Reports Server (NTRS)
Allton, J.H.
2009-01-01
The 6 Apollo missions that landed on the lunar surface returned 2196 samples comprised of 382 kg. The 58 samples weighing 21.5 kg collected on Apollo 11 expanded to 741 samples weighing 110.5 kg by the time of Apollo 17. The main goal on Apollo 11 was to obtain some material and return it safely to Earth. As we gained experience, the sampling tools and a more specific sampling strategy evolved. A summary of the sample types returned is shown in Table 1. By year 1989, some statistics on allocation by sample type were compiled [2]. The "scientific interest index" is based on the assumption that the more allocations per gram of sample, the higher the scientific interest. It is basically a reflection of the amount of diversity within a given sample type. Samples were also set aside for biohazard testing. The samples set aside and used for biohazard testing were represen-tative, as opposed to diverse. They tended to be larger and be comprised of less scientifically valuable mate-rial, such as dust and debris in the bottom of sample containers.
Heat flux instrumentation for Hyflite thermal protection system
NASA Technical Reports Server (NTRS)
Diller, T. E.
1994-01-01
Using Thermal Protection Tile core samples supplied by NASA, the surface characteristics of the FRCI, TUFI, and RCG coatings were evaluated. Based on these results, appropriate methods of surface preparation were determined and tested for the required sputtering processes. Sample sensors were fabricated on the RCG coating and adhesion was acceptable. Based on these encouraging results, complete Heat Flux Microsensors were fabricated on the RCG coating. The issue of lead attachment was addressed with the annnealing and welding methods developed at NASA Lewis. Parallel gap welding appears to be the best method of lead attachment with prior heat treatment of the sputtered pads. Sample Heat Flux Microsensors were submitted for testing in the NASA Ames arc jet facility. Details of the project are contained in two attached reports. One additional item of interest is contained in the attached AIAA paper, which gives details of the transient response of a Heat Flux Microsensors in a shock tube facility at Virginia Tech. The response of the heat flux sensor was measured to be faster than 10 micro-s.
Dowling, Zara; Ladeau, Shannon L; Armbruster, Peter; Biehler, Dawn; Leisnham, Paul T
2013-07-01
Mosquito populations are largely regulated by processes occurring at the larval stage. We sampled mosquito larval microhabitats (mostly water-holding containers) in six neighborhoods in the Washington, DC, area that varied in socioeconomic status (SES) and housing structure (row houses vs. stand-alone houses) to test associations among these neighborhood characteristics, microhabitat abundance and parameters, and mosquito occurrence and densities. Thirty-four percent (33.9%) of sampled microhabitats contained mosquito larvae, and 93.1% of larvae were Aedes albopictus Skuse or Culex pipiens L. Five specific container types (drains, corrugated flexible drainpipes, planters, garbage cans, and buckets) accounted for the majority of water-holding (56.0%) and mosquito-positive (50.6%) microhabitats sampled. We found no associations between SES or housing structure with total microhabitat abundance per yard, mosquito occurrence or mosquito densities per microhabitat. In contrast, container purpose varied with SES, with low SES neighborhoods having greater numbers of disused containers and lower numbers of functional containers than low and medium SES neighborhoods. Ae. albopictus were 83% more abundant in disused containers, whereas Cx. pipiens were more abundant in structural and functional containers, possibly owing to species-specific oviposition and development related to water quality. Ae. albopictus densities increased over the summer, whereas Cx. pipiens densities remained constant. Ae. albopictus is usually the dominant pest in urban areas in the eastern United States; therefore, integrated mosquito management programs should incorporate the elimination of disused containers to reduce its infestation and adult production, especially in low SES neighborhoods where they occur most frequently.
The effects of storing and transporting cryopreserved semen samples on dry ice
Til, David; Amaral, Vera L L; Salvador, Rafael A; Senn, Alfred; de Paula, Thais S
2016-01-01
Objective This study aimed to test the effects on sperm viability of transporting cryopreserved semen samples on dry ice. Methods Twenty normozoospermic semen samples were cryopreserved and divided into five groups. The samples in Group 1 were immersed in liquid nitrogen throughout the experiment in cryogenic storage tanks; the cryopreserved straws in Group 2 were placed in a Styrofoam box containing dry ice and kept under these conditions for 48 hours; the samples in Group 3 were kept for 48 hours on dry ice under the same conditions as the Group 2 samples, and were then moved to a storage tank filled with liquid nitrogen; Group 4 samples were also kept for 48 hours in dry ice storage, and the Styrofoam box containing the samples was shipped by plane to assess the effects of shipping; the samples in Group 5 were shipped together with the Group 4 samples and were placed in a storage tank with liquid nitrogen after spending 48 hours stored on dry ice. After thawing, sperm parameters were analyzed for viability, vitality, and motility; spermatozoa were also tested for mitochondrial activity. Results Significant decreases in motility recovery rates (P=0.01) and vitality (P=0.001) were observed in all groups when compared to the control group. Mitochondrial activity was significantly decreased only in Group 5 (P=0.04), as evidenced by greater numbers of sperm cells not stained by reagent 3,3'-diaminobenzidine. Conclusions Transportation did not affect the quality of cryopreserved semen samples, but dry ice as a means to preserve the samples during transportation had detrimental effects upon the sperm parameters assessed in this study. PMID:28050956
Chatasingh, S; Tapaneya-Olarn, W
1989-01-01
The comparison of specific gravity values of 561 urine samples from TS meter and reagent strip was made. The data were divided into two groups: group 1-less than 2+ protein contained urine samples and group 2--equal or more than 2+ protein contained urine samples. The results revealed that the specific gravity values from both methods in both groups were statistically different (p less than 0.01) but they were correlated at r = 0.84 (p less than 0.001) and r = 0.73 (p less than 0.001) in group 1 and group 2, respectively. It was concluded that the reagent strip is suitable for use as a screening test but it should not be considered when precise measurement is necessary.
1988-05-01
and 3 contained Mormon tea-type pollen, as well as high spine Asteraceae. Levels 3 and 4 contained Pooceoe and Opuntia. Level 4 contained modern oak...Sample Identification Quantity EP-1 Cheno-Am 12 Pinus 5 Poaceae 1 Opuntia 3 High Spine Asteraceae 1 V Ephedra torroyana-type 1 Indeterminate 1 - I...Total 24 Lycopodium 84 Concentration Value (grains/ml) 258.3 EP-2 Cheno-Am 19 Pinus 1 High Spine Asteraceae 2 Ephedra torreyana-type 1 Indeterminate 1
Titanium-Zirconium-Nickel Alloy Inside Marshall's Electrostatic Levitator (ESL)
NASA Technical Reports Server (NTRS)
2003-01-01
This Photo, which appeared on the July cover of `Physics Today', is of the Electrostatic Levitator (ESL) at NASA's Marshall Space Flight Center (MSFC). The ESL uses static electricity to suspend an object (about 3-4 mm in diameter) inside a vacuum chamber allowing scientists to record a wide range of physical properties without the sample contracting the container or any instruments, conditions that would alter the readings. Once inside the chamber, a laser heats the sample until it melts. The laser is then turned off and the sample cools, changing from a liquid drop to a solid sphere. In this particular shot, the ESL contains a solid metal sample of titanium-zirconium-nickel alloy. Since 1977, the ESL has been used at MSFC to study the characteristics of new metals, ceramics, and glass compounds. Materials created as a result of these tests include new optical materials, special metallic glasses, and spacecraft components.
2003-01-01
This Photo, which appeared on the July cover of `Physics Today', is of the Electrostatic Levitator (ESL) at NASA's Marshall Space Flight Center (MSFC). The ESL uses static electricity to suspend an object (about 3-4 mm in diameter) inside a vacuum chamber allowing scientists to record a wide range of physical properties without the sample contracting the container or any instruments, conditions that would alter the readings. Once inside the chamber, a laser heats the sample until it melts. The laser is then turned off and the sample cools, changing from a liquid drop to a solid sphere. In this particular shot, the ESL contains a solid metal sample of titanium-zirconium-nickel alloy. Since 1977, the ESL has been used at MSFC to study the characteristics of new metals, ceramics, and glass compounds. Materials created as a result of these tests include new optical materials, special metallic glasses, and spacecraft components.
Comparison of Hexavalent Chromium Leaching Levels of Zeoliteand Slag-based Concretes
NASA Astrophysics Data System (ADS)
Oravec, Jozef; Eštoková, Adriana
2017-06-01
In this experiment, the reference concrete samples containing Portland cement as binder and the concrete samples with the addition of ground granulated blast furnace slag (85% and 95%, respectively as replacement of Portland cement) and other samples containing ground zeolite (8% and 13%, respectively as replacement of Portland cement) were analyzed regarding the leachability of chromium. The prepared concrete samples were subjected to long-term leaching test for 300 days in three different leaching agents (distilled water, rainwater and Britton-Robinson buffer). Subsequently, the concentration of hexavalent chromium in the various leachates spectrophotometrically was measured. The leaching parameters as values of the pH and the conductivity were also studied. This experiment clearly shows the need for the regulation and control of the waste addition to the construction materials and the need for long-term study in relation to the leaching of heavy metals into the environment.
1.5 nm fabrication of test patterns for characterization of metrological systems
Babin, Sergey; Calafiore, Giuseppe; Peroz, Christophe; ...
2015-11-06
Any metrology tool is only as good as it is calibrated. The characterization of metrology systems requires test patterns at a scale about ten times smaller than the measured features. The fabrication of patterns with linewidths down to 1.5 nm is described. The test sample was designed in such a way that the distribution of linewidths appears to be random at any location. This pseudorandom test pattern is used to characterize dimensional metrology equipment over its entire dynamic range by extracting the modulation transfer function of the system. The test pattern contains alternating lines of silicon and tungsten silicide, eachmore » according to its designed width. As a result, the fabricated test samples were imaged using a transmission electron microscope, a scanning electron microscope, and an atomic force microscope. (C) 2015 American Vacuum Society.« less
Winters, W.J.; Pecher, I.A.; Waite, W.F.; Mason, D.H.
2004-01-01
This paper presents results of shear strength and acoustic velocity (p-wave) measurements performed on: (1) samples containing natural gas hydrate from the Mallik 2L-38 well, Mackenzie Delta, Northwest Territories; (2) reconstituted Ottawa sand samples containing methane gas hydrate formed in the laboratory; and (3) ice-bearing sands. These measurements show that hydrate increases shear strength and p-wave velocity in natural and reconstituted samples. The proportion of this increase depends on (1) the amount and distribution of hydrate present, (2) differences, in sediment properties, and (3) differences in test conditions. Stress-strain curves from the Mallik samples suggest that natural gas hydrate does not cement sediment grains. However, stress-strain curves from the Ottawa sand (containing laboratory-formed gas hydrate) do imply cementation is present. Acoustically, rock physics modeling shows that gas hydrate does not cement grains of natural Mackenzie Delta sediment. Natural gas hydrates are best modeled as part of the sediment frame. This finding is in contrast with direct observations and results of Ottawa sand containing laboratory-formed hydrate, which was found to cement grains (Waite et al. 2004). It therefore appears that the microscopic distribution of gas hydrates in sediment, and hence the effect of gas hydrate on sediment physical properties, differs between natural deposits and laboratory-formed samples. This difference may possibly be caused by the location of water molecules that are available to form hydrate. Models that use laboratory-derived properties to predict behavior of natural gas hydrate must account for these differences.
Mechanical degradation temperature of waste storage materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fink, M.C.; Meyer, M.L.
1993-05-13
Heat loading analysis of the Solid Waste Disposal Facility (SWDF) waste storage configurations show the containers may exceed 90{degrees}C without any radioactive decay heat contribution. Contamination containment is primarily controlled in TRU waste packaging by using multiple bag layers of polyvinyl chloride and polyethylene. Since literature values indicate that these thermoplastic materials can begin mechanical degradation at 66{degrees}C, there was concern that the containment layers could be breached by heating. To better define the mechanical degradation temperature limits for the materials, a series of heating tests were conducted over a fifteen and thirty minute time interval. Samples of a low-densitymore » polyethylene (LDPE) bag, a high-density polyethylene (HDPE) high efficiency particulate air filter (HEPA) container, PVC bag and sealing tape were heated in a convection oven to temperatures ranging from 90 to 185{degrees}C. The following temperature limits are recommended for each of the tested materials: (1) low-density polyethylene -- 110{degrees}C; (2) polyvinyl chloride -- 130{degrees}C; (3) high-density polyethylene -- 140{degrees}C; (4) sealing tape -- 140{degrees}C. Testing with LDPE and PVC at temperatures ranging from 110 to 130{degrees}C for 60 and 120 minutes also showed no observable differences between the samples exposed at 15 and 30 minute intervals. Although these observed temperature limits differ from the literature values, the trend of HDPE having a higher temperature than LDPE is consistent with the reference literature. Experimental observations indicate that the HDPE softens at elevated temperatures, but will retain its shape upon cooling. In SWDF storage practices, this might indicate some distortion of the waste container, but catastrophic failure of the liner due to elevated temperatures (<185{degrees}C) is not anticipated.« less
Hornish, Rex E; Hamlow, Philip J; Brown, Scott A
2003-01-01
A multilaboratory trial for determining ceftiofur-related residues in bovine and swine kidney and muscle, and bovine milk was conducted following regulatory guidelines of the U.S. Food and Drug Administration, Center for Veterinary Medicine. The methods convert all desfuroylceftiofur-related residues containing the intact beta-lactam ring to desfuroylceftiofur acetamide to establish ceftiofur residues in tissues. Four laboratories analyzed 5 sets of samples for each tissue. Each sample set consisted of a control/blank sample and 3 control samples fortified with ceftiofur at 0.5 Rm, Rm, and 2 Rm, respectively, where Rm is the U.S. tolerance assigned for ceftiofur residue in each tissue/matrix: 0.100 microg/mL for milk, 8.0 microg/g for kidney (both species), 1.0 microg/g for bovine muscle, and 2.0 microg/g for swine muscle. Each sample set also contained 2 samples of incurred-residue tissues (one > Rm and one < Rm) from animals treated with ceftiofur hydrochloride. All laboratories completed the method trial after a familiarization phase and test of system suitability in which they demonstrated > 80% recovery in pretrial fortified test samples. Results showed that the methods met all acceptable performance criteria for recovery, accuracy, and precision. Although sample preparation was easy, solid-phase extraction cartridge performance must be carefully evaluated before samples are processed. The liquid chromatography detection system was easily set up; however, the elution profile may require slight modifications. The procedures could clearly differentiate between violative (> Rm) and nonviolative (< Rm) ceftiofur residues. Participating laboratories found the procedures suitable for ceftiofur residue determination.
Sperm Hy-Liter™: an effective tool for the detection of spermatozoa in sexual assault exhibits.
De Moors, Anick; Georgalis, Tina; Armstrong, Gail; Modler, Jeff; Frégeau, Chantal J
2013-05-01
A fluorescence-based assay specifically targeting human spermatozoa was tested and optimized for best staining results using a variety of mock sexual assault samples. Swab clippings versus whole swabs were evaluated for best sample preparation and to simplify workflow (direct application versus swab extraction). The practicality and sensitivity of Sperm Hy-Liter™ was compared to our current phase contrast microscopy protocol for searching for the presence of spermatozoa. Sperm Hy-Liter™ was more sensitive than phase contrast microscopy and was able to detect spermatozoa more effectively in actual sexual assault samples (recent [N=240] or 24 years old [N=4]) containing few spermatozoa. Correlations were drawn between the Sperm Hy-Liter™ spermatozoa counts and the AmpFlSTR(®) Profiler(®) Plus male profiles generated from the sperm cell DNA fractions of semen containing swabs and swab clippings. In addition, recovered spermatozoa from Sperm Hy-Liter™-stained slides with greater than 40 spermatozoa produced full STR male profiles in 20.3% of slides tested and partial STR male profiles in 52.8% of slides tested. The adoption of Sperm Hy-Liter™ offers a means to standardize and improve the efficiency of the microscopic screening of sexual assault evidence. Crown Copyright © 2013. Published by Elsevier Ireland Ltd. All rights reserved.
Evidence of technetium and iodine release from a sodalite-bearing ceramic waste form
Neeway, James J.; Qafoku, Nikolla P.; Williams, Benjamin D.; ...
2015-12-31
We proposed sodalites as a possible host of certain radioactive species, specifically 99Tc and 129I, which may be encapsulated into the cage structure of the mineral. To demonstrate the ability of this framework silicate mineral to encapsulate and immobilize 99Tc and 129I, single-pass flow-through (SPFT) tests were conducted on a sodalite-bearing multi-phase ceramic waste form produced through a steam reforming process. We produced two samples made using a steam reformer samples using nonradioactive I and Re (as a surrogate for Tc), while a third sample was produced using actual radioactive tank waste containing Tc and added Re. One of themore » non-radioactive samples was produced with an engineering-scale steam reformer while the other non-radioactive sample and the radioactive sample were produced using a bench-scale steam reformer. For all three steam reformer products, the similar steady-state dilute-solution release rates for Re, I, and Tc at pH (25 C) 9 and 40 C were measured. However, it was found that the Re, I, and Tc releases were equal or up to 4.5x higher compared to the release rates of the network-forming elements, Na, Al, and Si. Moreover, the similar releases of Re and Tc in the SPFT test, and the similar time-dependent shapes of the release curves for samples containing I, suggest that Re, Tc, and I partition to the sodalite minerals during the steam reforming process.« less
Methyl bromide determination in selected foods by headspace technique.
Daft, J L
1993-01-01
A headspace method used earlier for determining methyl bromide (MB) in assorted nuts and peanut butters has been successfully applied to other foods that could potentially contain traces of this toxic fumigant. The foods tested include 63 off-the-shelf spices and seasonings, 83 table-ready items (grain-based, dried, or highly seasoned), 30 dried fruits and trail mixes, and 38 oil-based items (oil-seeds, cooking oils, or spicy oil-based dressings). Sample headspace gas is produced by blending < or = 50 g sample in 250 +/- 50 mL aqueous solution in a sealed 1000 mL blender cup. After equilibration at 25 degrees C, the headspace is sampled with a gas-tight syringe and injected into a dual column-dual detector gas chromatograph. One determination is made with a 20% OV-101 packed column and a 63Ni electron capture detector (ECD), the other with a GS-Q wide-bore capillary column and a Hall electrolytic conductivity detector (HECD). Of the approximately 200 samples tested, none contained detectable MB residue at a quantitation limit < 100 ng/g sample. All fortified samples yielded MB recovery. Samples were fortified at levels ranging from 78 to 3250 ng MB/g. Recoveries ranged from a mean high of 56% for spices and seasonings to a mean low of 30% for oil-based foods. The overall recovery and CV, including the results from assorted nuts and peanut butters, were 46 and 33%, respectively.
Permenter, Jessalyn; Ishwar, Arjun; Rounsavall, Angie; Smith, Maddie; Faske, Jennifer; Sailey, Charles J; Alfaro, Maria P
2015-12-01
Proper storage of whole blood is crucial for isolating nucleic acids from leukocytes and to ensure adequate performance of downstream assays in the molecular diagnostic laboratory. Short-term and long-term storage recommendations are lacking for successful isolation of genomic DNA (gDNA). Container type (EDTA or heparin), temperature (4 °C and room temperature) and time (1-130 days) were assessed as criterion for sample acceptance policies. The percentage of integrated area (%Ti) between 150 and 10,000 bp from the 2200 TapeStation electropherogram was calculated to measure gDNA degradation. Refrigerated EDTA samples yielded gDNA with low %Ti (high quality). Heparinized samples stored at room temperature yielded gDNA of worst quality. Downstream analysis demonstrated that the quality of the gDNA correlated with the quality of the data; samples with high %Ti generated significantly lower levels of high molecular weight amplicons. Recommendations from these analyses include storing blood samples intended for nucleic acid isolation in EDTA tubes at 4 °C for long term storage (>10 days). gDNA should be extracted within 3 days when blood is stored at room temperature regardless of the container. Finally, refrigerated heparinized samples should not be stored longer than 9 days if expecting high quality gDNA isolates. Laboratories should consider many factors, in addition to the results obtained herein, to update their policies for sample acceptance for gDNA extraction intended for molecular genetic testing. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Rummel, John D.
2001-01-01
Before martian soil and rock samples can be distributed to the research community, the returned materials will initially be quarantined and examined in a proposed BSL-4 containment facility to assure that no putative martian microorganisms or attendant potential biohazards exist. During the initial quarantine, state-of-the-art life detection and biohazard testing of the returned martian samples will be conducted. Life detection, as defined here in regard to Mars sample return missions, is the detection of living organisms and/or materials that have been derived from living organisms that may be present in the sample.
Grace Sun; Rebecca E. Ibach; Meghan Faillace; Marek Gnatowski; Jessie A. Glaeser; John Haight
2016-01-01
After exposure in the field and laboratory soil block culture testing, the void content of woodâplastic composite (WPC) decking boards was compared to unexposed samples. A void volume analysis was conducted based on calculations of sample density and from micro-computed tomography (microCT) data. It was found that reference WPC contains voids of different sizes from...
ERIC Educational Resources Information Center
Missouri State Dept. of Elementary and Secondary Education, Jefferson City.
This booklet contains sample items from the Missouri social studies test for eighth graders. The first sample is based on a speech delivered by Elizabeth Cady Stanton in the mid-1880s, which proposed a new approach to raising girls. Students are directed to use their own knowledge and the speech excerpt to do three activities. The second sample…
Bradfield, A.D.; Flexner, N.M.; Webster, D.A.
1993-01-01
An investigation of water quality, organic sediment chemistry, and biological conditions of streams near an abandoned wood-preserving plant site at Jackson, Tennessee, was conducted during December 1990. The study was designed to assess the extent of possible contamination of water and biota in the streams from creosote-related discharge originating at this Superfund site. Central Creek, adjacent to the plant, had degraded water quality and biological conditions. Water samples from the most downstream station on Central Creek contained 30 micrograms per liter of pentachlorophenol, which exceeds the State's criterion maximum concentrations of 9 micrograms per liter for fish and aquatic life. Bottom-sediment samples from stations on Central Creek contained concentrations of acenaphthene, napthalene, and phenanthrene ranging from 1,400 to 2,500 micrograms per kilogram. Chronic or acute toxicity resulted during laboratory experiments using test organisms exposed to creosote-related contaminants. Sediment elutriate samples from Central Creek caused slightly to highly toxic effects on Ceriodaphnia dubia. Pimephales promelas, and Photobacterium phosphoreum. Fish-tissue samples from this station contained concentrations of naphthalene. dibenzofuran, fluorene, and phenanthrene ranging from 1.5 to 3.9 micrograms per kilogram Blue-green algae at this station represented about 79 percent of the organisms counted, whereas diatoms accounted for only 11 percent. Benthic invertebrate and fish samples from Central Creek had low diversity and density. Sediment samples from a station on the South Fork Forked Deer River downstream from its confluence with Central Creek contained concentrations of acenaphthene, anthracene, chrysene, fluoranthene, fluorene, pyrere, and phenanthrene ranging from 2,800 to 69,000 micrograms per kilogram. Sediment elutriate samples using water as elutriate from this station contained concentrations of extractable organic compounds ranging from an estimated 43 to 420 micrograms per liter. Sediment elutriate samples were toxic to Ceriodaphnia dubta, Pimephales promelas, Photobacterium phosphoreum, and Salenastrum capricornulum.
ERIC Educational Resources Information Center
Tabor, Josh
2010-01-01
On the 2009 AP[c] Statistics Exam, students were asked to create a statistic to measure skewness in a distribution. This paper explores several of the most popular student responses and evaluates which statistic performs best when sampling from various skewed populations. (Contains 8 figures, 3 tables, and 4 footnotes.)
Mehdi Tajvidi; Mokhtar Feizmand; Robert H. Falk; Colin Felton
2009-01-01
In order to quantify the effect of temperature on the mechanical properties of pure nylon 6 and its composite with cellulose fibers (containing 25 wt% cellulose fibers), the materials were sampled and tested at three representative temperatures of 256, 296, and 336 K. Flexural and tensile tests were performed and the reductions in mechanical properties were evaluated....
A 12 year EDF study of concrete creep under uniaxial and biaxial loading
Charpin, Laurent; Le Pape, Yann; Coustabeau, Eric; ...
2017-11-04
This paper presents a 12-year-long creep and shrinkage experimental campaign on cylindrical and prismatic concrete samples under uniaxial and biaxial stress, respectively. The motivation for the study is the need for predicting the delayed strains and the pre-stress loss of concrete containment buildings of nuclear power plants. Two subjects are central in this regard: the creep strain's long-term evolution and the creep Poisson's ratio. A greater understanding of these areas is necessary to ensure reliable predictions of the long-term behavior of the concrete containment buildings.Long-term basic creep appears to evolve as a logarithm function of time in the range ofmore » 3 to 10 years of testing. Similar trends are observed for drying creep, autogenous shrinkage, and drying shrinkage testing, which suggests that all delayed strains obtained using different loading and drying conditions originate from a common mechanism.The creep Poisson's ratio derived from the biaxial tests is approximately constant over time for both the basic and drying creep tests (creep strains corrected by the shrinkage strain).It is also shown that the biaxial non-drying samples undergo a significant increase in Young's modulus after 10 years.« less
A 12 year EDF study of concrete creep under uniaxial and biaxial loading
DOE Office of Scientific and Technical Information (OSTI.GOV)
Charpin, Laurent; Le Pape, Yann; Coustabeau, Eric
This paper presents a 12-year-long creep and shrinkage experimental campaign on cylindrical and prismatic concrete samples under uniaxial and biaxial stress, respectively. The motivation for the study is the need for predicting the delayed strains and the pre-stress loss of concrete containment buildings of nuclear power plants. Two subjects are central in this regard: the creep strain's long-term evolution and the creep Poisson's ratio. A greater understanding of these areas is necessary to ensure reliable predictions of the long-term behavior of the concrete containment buildings.Long-term basic creep appears to evolve as a logarithm function of time in the range ofmore » 3 to 10 years of testing. Similar trends are observed for drying creep, autogenous shrinkage, and drying shrinkage testing, which suggests that all delayed strains obtained using different loading and drying conditions originate from a common mechanism.The creep Poisson's ratio derived from the biaxial tests is approximately constant over time for both the basic and drying creep tests (creep strains corrected by the shrinkage strain).It is also shown that the biaxial non-drying samples undergo a significant increase in Young's modulus after 10 years.« less
An optical instrument to test pesticide residues in agricultural products
NASA Astrophysics Data System (ADS)
Qiu, Zhengjun; Zheng, Wenzhong; Fang, Hui; He, Yong
2005-10-01
Pesticide is one of the indispensability materials in modern agricultural management, however the excessive use of pesticides has threatened the ecological environment and people's health. This paper introduced an optical instrument to test the pesticide residues in agricultural products based on the inhibition rate of organophosphates against acrtyl-cholinesterase (AchE). The instrument consists mainly of a solid light source with 410nm wavelength, a sampling container, an optical sensor, a temperature sensor, and a MCU based data acquisition board. The light illuminated through the liquid in the sampling container, and the absorptivity was determined by the amount of the pesticide residues in the liquid. This paper involves the design of optical testing system, the data acquisition and calibration of the optical sensor, the design of microcontroller-based electrical board. Tests were done to reveal the affection of temperature and reacting time on AchE, to establish the relationship between the amount of methamidophos and dichlorvos with AchE. The results showed that the absorption rate was related to the pesticide residues and it could be concluded that the pesticide residues exceeded the normal level when the inhibition rate was over 50 percent. The instrument has potential application in vegetable markets.
Bowyer, A E; Hillarp, A; Ezban, M; Persson, P; Kitchen, S
2016-07-01
Essentials Validated assays are required to precisely measure factor IX (FIX) activity in FIX products. N9-GP and two other FIX products were assessed in various coagulation assay systems at two sites. Large variations in FIX activity measurements were observed for N9-GP using some assays. One-stage and chromogenic assays accurately measuring FIX activity for N9-GP were identified. Background Measurement of factor IX activity (FIX:C) with activated partial thromboplastin time-based one-stage clotting assays is associated with a large degree of interlaboratory variation in samples containing glycoPEGylated recombinant FIX (rFIX), i.e. nonacog beta pegol (N9-GP). Validation and qualification of specific assays and conditions are necessary for the accurate assessment of FIX:C in samples containing N9-GP. Objectives To assess the accuracy of various one-stage clotting and chromogenic assays for measuring FIX:C in samples containing N9-GP as compared with samples containing rFIX or plasma-derived FIX (pdFIX) across two laboratory sites. Methods FIX:C, in severe hemophilia B plasma spiked with a range of concentrations (from very low, i.e. 0.03 IU mL(-1) , to high, i.e. 0.90 IU mL(-1) ) of N9-GP, rFIX (BeneFIX), and pdFIX (Mononine), was determined at two laboratory sites with 10 commercially available one-stage clotting assays and two chromogenic FIX:C assays. Assays were performed with a plasma calibrator and different analyzers. Results A high degree of variation in FIX:C measurement was observed for one-stage clotting assays for N9-GP as compared with rFIX or pdFIX. Acceptable N9-GP recovery was observed in the low-concentration to high-concentration samples tested with one-stage clotting assays using SynthAFax or DG Synth, or with chromogenic FIX:C assays. Similar patterns of FIX:C measurement were observed at both laboratory sites, with minor differences probably being attributable to the use of different analyzers. Conclusions These results suggest that, of the reagents tested, FIX:C in N9-GP-containing plasma samples can be most accurately measured with one-stage clotting assays using SynthAFax or DG Synth, or with chromogenic FIX:C assays. © 2016 International Society on Thrombosis and Haemostasis.
Recent status of resist outgas testing for metal containing resists at EIDEC
NASA Astrophysics Data System (ADS)
Shiobara, Eishi; Mikami, Shinji; Yamada, Kenji
2018-03-01
The metal containing resist is one of the strong candidates for high lithographic performance Extreme Ultraviolet (EUV) resists. EIDEC has prepared the infrastructure for outgas testing in hydrogen environment for metal containing resists at High Power EUV irradiation tool (HPEUV). We have experimentally obtained the preliminary results of the non-cleanable metal contamination on witness sample using model material by HPEUV [1]. The metal contamination was observed at only the condition of hydrogen environment. It suggested the generation of volatile metal hydrides by hydrogen radicals. Additionally, the metal contamination on a witness sample covered with Ru was not removed by hydrogen radical cleaning. The strong interaction between the metal hydride and Ru was confirmed by the absorption simulation [2]. Recently, ASML announced a resist outgassing barrier technology using Dynamic Gas Lock (DGL) membrane located between projection optics and wafer stage [3, 4]. DGL membrane blocks the diffusion of all kinds of resist outgassing to the projection optics and prevents the reflectivity loss of EUV mirrors. The investigation of DGL membrane for high volume manufacturing is just going on. It extends the limitation of material design for EUV resists. However, the DGL membrane has an impact for the productivity of EUV scanners due to the transmission loss of EUV light and the necessity of periodic maintenance. The well understanding and control of the outgassing characteristics of metal containing resists may help to improve the productivity of EUV scanner. We consider the outgas evaluation for the resists still useful. For the improvement of resist outgas testing in hydrogen, there are some issues such as the contamination limited regime, the optimization of exposure dose to obtain the measurable contamination film thickness and the detection of minimum amount of metal related outgas species generated. We are considering a new platform of outgas testing for metal containing resists based on the electron-beam irradiation system as one of the solutions for these issues. The concept is presented in this paper.
Rashid, Goran M M; Duran-Pena, Maria Jesus; Rahmanpour, Rahman; Sapsford, Devin; Bugg, Timothy D H
2017-04-10
The aim of the study was to isolate bacterial lignin-degrading bacteria from municipal solid waste soil, and to investigate whether they could be used to delignify lignocellulose-containing soil, and enhance methane release. A set of 20 bacterial lignin degraders, including 11 new isolates from municipal solid waste soil, were tested for delignification and phenol release in soil containing 1% pine lignocellulose. A group of 7 strains were then tested for enhancement of gas release from soil containing 1% lignocellulose in small-scale column tests. Using an aerobic pre-treatment, aerobic strains such as Pseudomonas putida showed enhanced gas release from the treated sample, but four bacterial isolates showed 5-10 fold enhancement in gas release in an in situ experiment under microanaerobic conditions: Agrobacterium sp., Lysinibacillus sphaericus, Comamonas testosteroni, and Enterobacter sp.. The results show that facultative anaerobic bacterial lignin degraders found in landfill soil can be used for in situ delignification and enhanced gas release in soil containing lignocellulose. The study demonstrates the feasibility of using an in situ bacterial treatment to enhance gas release and resource recovery from landfill soil containing lignocellulosic waste. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Castelló, Ana; Francès, Francesc; Verdú, Fernando
2017-09-01
Presumptive tests for blood are very simple and sensitive tests used in the search for evidence. They also provide initial information on the nature of stains. A second test can confirm their nature. However, these tests can present false-negative results for different reasons. Some of those reasons have been studied, while others, those caused by the substrate material that contains the stain, are less well known. This work studies the effect of one component of a leather substrate-quebracho extract-on presumptive and human hemoglobin blood tests. Assays were performed using samples of blood dilutions contaminated with quebracho extract and others formed on a substrate containing the contaminant. Results show an undoubted interference that causes false negatives and even visible to the naked eye stains and also indicate that some tests (phenolphthalein) are more affected than others. Examiners should be taken into account when working on this kind of substrates. © 2017 American Academy of Forensic Sciences.
Sterling, D A; Lewis, R D; Luke, D A; Shadel, B N
2000-06-01
Dust wipe samples collected in the field were tested by nondestructive X-ray fluorescence (XRF) followed by laboratory analysis with flame atomic absorption spectrophotometry (FAAS). Data were analyzed for precision and accuracy of measurement. Replicate samples with the XRF show high precision with an intraclass correlation coefficient (ICC) of 0.97 (P<0.0001) and an overall coefficient of variation of 11.6%. Paired comparison indicates no statistical difference (P=0.272) between XRF and FAAS analysis. Paired samples are highly correlated with an R(2) ranging between 0.89 for samples that contain paint chips and 0.93 for samples that do not contain paint chips. The ICC for absolute agreement between XRF and laboratory results was 0.95 (P<0.0001). The relative error over the concentration range of 25 to 14,200 microgram Pb is -12% (95% CI, -18 to -5). The XRF appears to be an excellent method for rapid on-site evaluation of dust wipes for clearance and risk assessment purposes, although there are indications of some confounding when paint chips are present. Copyright 2000 Academic Press.
Gaudin, Valerie; Juhel-Gaugain, Murielle; Morétain, Jean-Pierre; Sanders, Pascal
2008-12-01
Premi Test contains viable spores of a strain of Bacillus stearothermophilus which is sensitive to antimicrobial residues, such as beta-lactams, tetracyclines, macrolides and sulphonamides. The growth of the strain is inhibited by the presence of antimicrobial residues in muscle tissue samples. Premi Test was validated according to AFNOR rules (French Association for Normalisation). The AFNOR validation was based on the comparison of reference methods (French Official method, i.e. four plate test (FPT) and the STAR protocol (five plate test)) with the alternative method (Premi Test). A preliminary study was conducted in an expert laboratory (Community Reference Laboratory, CRL) on both spiked and incurred samples (field samples). Several method performance criteria (sensitivity, specificity, relative accuracy) were estimated and are discussed, in addition to detection capabilities. Adequate agreement was found between the alternative method and the reference methods. However, Premi Test was more sensitive to beta-lactams and sulphonamides than the FPT. Subsequently, a collaborative study with 11 laboratories was organised by the CRL. Blank and spiked meat juice samples were sent to participants. The expert laboratory (CRL) statistically analysed the results. It was concluded that Premi Test could be used for the routine determination of antimicrobial residues in muscle of different animal origin with acceptable analytical performance. The detection capabilities of Premi Test for beta-lactams (amoxicillin, ceftiofur), one macrolide (tylosin) and tetracycline were at the level of the respective maximum residue limits (MRL) in muscle samples or even lower.
Grimmond, Terry; Neelakanta, Anu; Miller, Barbara; Saiyed, Asif; Gill, Pam; Cadnum, Jennifer; Olmsted, Russell; Donskey, Curtis; Pate, Kimberly; Miller, Katherine
2018-05-22
A 2015 study matching use of disposable and reusable sharps containers (DSCs, RSCs) with Clostridium difficile infection (CDI) incidence found a decreased incidence with DSCs. We conducted microbiologic samplings and examined the literature and disease-transmission principles to evaluate the scientific feasibility of such an association. (i) 197 RSCs were sampled for C. difficile at processing facilities; (ii) RSCs were challenged with high C. difficile densities to evaluate efficacy of automated decontamination; and (iii) 50 RSCs and 50 DSCs were sampled in CDI patient rooms in 7 hospitals. Results were coupled with epidemiologic studies, clinical requirements, and chain-of-infection principles, and tests of evidence of disease transmission were applied. C. difficile spores were found on 9 of 197 (4.6%) RSCs prior to processing. Processing completely removed C. difficile. In CDI patient rooms, 4 of 50 RSCs (8.0%) and 8 of 50 DSCs (16.0%) had sub-infective counts of C. difficile (P = .27). DSCs were in permanent wall cabinets; RSCs were removed and decontaminated frequently. With C. difficile bioburden being sub-infective on both DSCs and RSCs, sharps containers being no-touch, and glove removal required after sharps disposal, we found 2 links in the chain of infection to be broken and 5 of 7 tests of evidence to be unmet. We conclude that sharps containers pose no risk of C. difficile transmission. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
O'Connor, Brian; Hernandez, Deborah; Hornsby, Linda; Brown, Maria; Horton-Mullins, Kathryn
2017-01-01
NASA's Sample Cartridge Assembly (SCA) project is responsible for designing and validating a payload that contains materials research samples in a sealed environment. The SCA will be heated in the European Space Agency's (ESA) Low Gradient Furnace (LGF) that is housed inside the Material Science Research Rack (MSRR) located on the International Space Station (ISS). The first Principle Investigator (PI) to utilize the SCA will focus on Gravitational Effects on Distortion in Sintering (GEDS) research. This paper will give a summary of the design and development test effort for the GEDS SCA and will discuss the role of thermal analysis in developing test profiles to meet the science and engineering requirements. Lessons learned will be reviewed and salient design features that may differ for each PI will be discussed.
NASA Astrophysics Data System (ADS)
Rudnev, V. S.; Lukiyanchuk, I. V.; Vasilyeva, M. S.; Morozova, V. P.; Zelikman, V. M.; Tarkhanova, I. G.
2017-11-01
W-containing oxide layers fabricated on titanium and aluminum alloys by Plasma electrolytic oxidation (PEO) have been tested in the reaction of the peroxide oxidation of thiophene. Samples with two types of coatings have been investigated. Coatings I contained tungsten oxide in the matrix and on the surface of amorphous silica-titania or silica-alumina layers, while coatings II comprised crystalline WO3 and/or Al2(WO4)3. Aluminum-supported catalyst containing a smallest amount of transition metals in the form of tungsten oxides and manganese oxides in low oxidation levels showed high activity and stability.
Disassa, Nigatu; Sibhat, Berhanu; Mengistu, Shimelis; Muktar, Yimer; Belina, Dinaol
2017-01-01
A cross-sectional study was conducted from October 2014 to July 2015 to determine the prevalence and populations of E. coli as well as the prevalence and antimicrobial susceptibility of E. coli O157:H7 isolated from raw milk. Biochemical and serological tests methods were used to confirm E. coli and E. coli O157:H7 and isolates were subjected to antimicrobial susceptibility test using the agar disc diffusion method. Out of 380 raw milk samples examined, 129 (33.9%) and 11 (2.9%) were contaminated with E. coli and E. coli O157:H7, respectively. The highest prevalence was recorded in samples obtained from vendors (39.1%, 4.978 ± 0.180 log 10 /ml) compared with samples from farmers (28.1%, 3.93 ± 0.01 log 10 /ml) with significant differences ( P = 0.02). The frequency of contamination was higher in the samples collected from milk that was stored and transported in plastic containers (39.4%) than in the containers made of stainless steel (23.0%) ( P = 0.002). The antimicrobial susceptibility profile showed that E. coli O157:H7 were resistant to tetracycline (81.8%), streptomycin (81.8%), and kanamycin (63.6%). Milk samples were produced and handled under poor hygienic conditions, stored, and transported in inappropriate containers and under temperature abuse conditions leading to high health risk to the consumers. Additional studies would be needed to establish association between the occurrences of E. coli O157:H7 in raw milk and all the risk factors involved in and around Asosa town.
NASA Astrophysics Data System (ADS)
Astashev, M. E.; Belosludtsev, K. N.; Kharakoz, D. P.
2014-05-01
One of the most accurate methods for measuring the compressibility of liquids is resonance measurement of sound velocity in a fixed-length interferometer. This method combines high sensitivity, accuracy, and small sample volume of the test liquid. The measuring principle is to study the resonance properties of a composite resonator that contains a test liquid sample. Ealier, the phase-locked loop (PLL) scheme was used for this. In this paper, we propose an alternative measurement scheme based on digital analysis of harmonic signals, describe the implementation of this scheme using commercially available data acquisition modules, and give examples of test measurements with accuracy evaluations of the results.
NASA Astrophysics Data System (ADS)
Prošek, Zdeněk; Trejbal, Jan; Topič, Jaroslav; Plachý, Tomáš; Tesárek, Pavel
2017-09-01
This article is focused on the mechanical testing of cement-based samples containing a micronized waste marble powder used as replacement of standard binders. Tested materials consisted of cement CEM I 42.5 R (Radotín, Czech Republic) and three different amounts of the marbles (25, 50 and 70 wt. %). Standard bending and compressive tests of the prismatic samples having dimensions equal to 40 × 40 × 160 mm were done in order to reveal an influence of marble amount on flexural and compressive strength, respectively. Moreover, the dynamic modulus of elasticity and dynamic shear modulus were examined and compared after 7 and 28 days of mixture curing.
Egg Contribution Towards the Diet of Pregnant Latinas
Bermúdez-Millán, Ángela; Hromi-Fiedler, Amber; Damio, Grace; Segura-Pérez, Sofia; Pérez-Escamilla, Rafael
2011-01-01
Proper nutrition during gestation is important to prevent adverse pregnancy outcomes. Eggs contain many important nutrients necessary for fetal development and human survival. Three focus groups were conducted with Latina women living in Connecticut to identify cultural beliefs toward egg consumption during pregnancy, traditional egg dishes, and methods of preparation. A cross-sectional study was then carried out with a sample of predominately Puerto Rican pregnant Latinas (N = 241) to identify the frequency of consumption of eggs and egg-containing dishes as well as methods of preparation using a tailored food frequency questionnaire modified for this population. Paired sample t-tests were used to examine if there were differences in weekly mean egg intake patterns between the year prior to the pregnancy and during pregnancy based on a Food Frequency Questionnaire. Women were categorized into eggs consumers and non-consumers if they consumed or did not consume eggs during the previous day based on 24-hour recall data. Independent-sample t-test and chi-square cross-tabulation analyses were conducted to examine the association between egg consumption and nutrient intake categories. Results showed that eggs and egg-containing traditional dishes are consumed by Latinas before and during pregnancy. Egg consumers had higher intakes of protein, fat, vitamin K, vitamin E, selenium, beta carotene, lutein and zeaxanthin, cholesterol, total polyunsaturated fatty acids, and docosahexaenoic acid. Eggs contribute significantly to the diet of pregnant Latinas. PMID:21883065
Crowe, John B; Lanzarotta, Adam; Witkowski, Mark R; Andria, Sara E
2015-07-01
Suspect hypodermic needles and syringes were seized from an unlicensed individual who was allegedly injecting patients with silicone (polydimethylsiloxane [PDMS]) for cosmetic enhancement. Since control syringe barrels and needles often contain an interfering PDMS lubricant, a risk for false positives of foreign PDMS exists. The focus of this report was to minimize this risk and determine a quick and reliable test for the presence of blood in PDMS matrices. Using ATR-FT-IR spectroscopy, the risk for false-positive identification of foreign PDMS was reduced by (i) overfilling the sampling aperture to prevent spectral distortions and (ii) sampling a region of the suspect syringe/needle assembly where manufacturer-applied PDMS is not typically located. Analysis for blood indicated that the Teichman microchemical test was effective for detecting blood in the presence of PDMS. Overall, detecting PDMS established intent and detecting blood established that the needle containing the PDMS had been used for injection. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
NASA Astrophysics Data System (ADS)
Mrozek, T.; Perlicki, K.; Tajmajer, T.; Wasilewski, P.
2017-08-01
The article presents an image analysis method, obtained from an asynchronous delay tap sampling (ADTS) technique, which is used for simultaneous monitoring of various impairments occurring in the physical layer of the optical network. The ADTS method enables the visualization of the optical signal in the form of characteristics (so called phase portraits) that change their shape under the influence of impairments such as chromatic dispersion, polarization mode dispersion and ASE noise. Using this method, a simulation model was built with OptSim 4.0. After the simulation study, data were obtained in the form of images that were further analyzed using the convolutional neural network algorithm. The main goal of the study was to train a convolutional neural network to recognize the selected impairment (distortion); then to test its accuracy and estimate the impairment for the selected set of test images. The input data consisted of processed binary images in the form of two-dimensional matrices, with the position of the pixel. This article focuses only on the analysis of images containing chromatic dispersion.
Schall, R; Müller, F O; Duursema, L; Groenewoud, G; Hundt, H K; Middle, M V; Mogilnicka, E M; Swart, K J
1995-11-01
Twenty male volunteers who were slow metabolisers of isoniazid, completed this single-blind, single-dose, randomised, cross-over study to compare the bioavailability of rifampicin (CAS 13292-46-1), isoniazid (CAS 54-85-3) and ethambutol (CAS 1070-11-7) from Myrin tablets (test preparation) with the bioavailability of these drugs from a combination of capsules containing rifampicin and tablets containing isoniazid and ethambutol (reference). There were 2 treatment periods and on clinic days volunteers were given either the reference (300 mig rifampicin plus 200 mg isoniazid and 600 mg ethambutol HCl), or the test preparation (300 mg rifampicin, 150 mg isoniazid and 600 mg ethambutol HCl). Serial blood samples were drawn from the volunteers and rifampicin, isoniazid and ethambutol assays were performed. The results of this study indicate that the test preparation is equivalent to the reference with respect to both the rate and the extent of absorption of rifampicin, isoniazid (after adjustment for the different doses of isoniazid and ethambutol).
Plage, Bernd; Berg, Anna-Dolores; Luhn, Steven
2008-05-20
The differentiation of 25 automotive clear coats was evaluated using pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS). The samples were selected from eight different groups of samples which slightly differ in their infrared spectra. Most of the samples could be differentiated by visual inspection of the pyrograms. As an objective mean for evaluation a new software based on the comparison of chromatograms was tested for automatic classification considering retention times as well as mass spectra. The database was formed by the triplicate results of the set of the 25 samples. Normally a replicate measurement of a sample yields the best fit by library search. In addition, for most groups classification with moderate fits are obtained for samples belonging to the same group. Some samples are completely rearranged forming a new group of similar samples containing five samples from three different IR groups and four samples of three other groups, respectively. Furthermore detailed visual recognition of individual pyrolysis products allows subgrouping. Therefore, most samples can be differentiated from each other by Py-GC/MS. The exception were three sample groups containing two samples each, which could not be differentiated from each other neither by library search nor by recognition of minor individual pyrolysis products.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wolfe, M.; Norman, D.
Birds and mammals exposed to waterborne mercury (Hg) and methylmercury (MeHg) were collected and/or sampled at Clear Lake, California, USA, to field test the predictive wildlife criteria model developed for the Great Lakes Water Quality Initiative (GLWQI). Tissue samples collected from sampled animals were analyzed for Hg and organochlorine residues, and for selected physiologic parameters known to be affected by Hg. All mammalian organ tissues analyzed contained less than 12 ppm total Hg, wet weight. All avian tissue samples analyzed contained less than 3 ppm total Hg, wet weight. No evidence of Hg-associated health effects was found. Tissue Hg residuesmore » were compared with water, sediment, and animal food samples to characterize bioaccumulation of mercury in the Clear Lake food web. Total Hg bioaccumulation factors for the Clear Lake site closest to the Hg source were: TL-2: 11,100; TL-3: 31,200; TL-4, 190,000. The results support the final wildlife criterion and suggest that the GLWQI model, with site-specific modifications, is predictive for other Hg-bearing aquatic systems.« less
Rhoderick, George C
2007-04-01
New US federal low-level automobile emission requirements, for example zero-level-emission vehicle (ZLEV), for hydrocarbons and other species, have resulted in the need by manufacturers for new certified reference materials. The new emission requirement for hydrocarbons requires the use, by automobile manufacturing testing facilities, of a 100 nmol mol(-1) propane in air gas standard. Emission-measurement instruments are required, by federal law, to be calibrated with National Institute of Standards and Technology (NIST) traceable reference materials. Because a NIST standard reference material (SRM) containing 100 nmol mol(-1) propane was not available, the US Environmental Protection Agency (EPA) and the Automobile Industry/Government Emissions Research Consortium (AIGER) requested that NIST develop such an SRM. A cylinder lot of 30 gas mixtures containing 100 nmol mol(-1) propane in air was prepared in 6-L aluminium gas cylinders by a specialty gas company and delivered to the Gas Metrology Group at NIST. Another mixture, contained in a 30-L aluminium cylinder and included in the lot, was used as a lot standard (LS). Using gas chromatography with flame-ionization detection all 30 samples were compared to the LS to obtain the average of six peak-area ratios to the LS for each sample with standard deviations of <0.31%. The average sample-to-LS ratio determinations resulted in a range of 0.9828 to 0.9888, a spread of 0.0060, which corresponds to a relative standard deviation of 0.15% of the average for all 30 samples. NIST developed its first set of five propane in air primary gravimetric standards covering a concentration range 91 to 103 nmol mol(-1) with relative uncertainties of 0.15%. This new suite of propane gravimetric standards was used to analyze and assign a concentration value to the SRM LS. On the basis of these data each SRM sample was individually certified, furnishing the desired relative expanded uncertainty of +/-0.5%. Because automobile companies use total hydrocarbons to make their measurements, it was also vital to assign a methane concentration to the SRM samples. Some of the SRM samples were analyzed and found to contain 1.2 nmol mol(-1) methane. Twenty-five of the samples were certified and released as SRM 2765.
Irii, Toshiaki; Maebashi, Kyoko; Fukui, Kenji; Sohma, Ryoko; Matsumoto, Sari; Takasu, Shojiro; Iwadate, Kimiharu
2016-05-01
Investigation of drug-related crimes, such as violation of the Stimulant Drug Control Law, requires identifying the used drug (mainly stimulant drugs, methamphetamine hydrochloride) from a drug solution and the DNA type of the drug user from a trace of blood left in the syringe used to inject the drug. In current standard test procedures, DNA typing and methamphetamine detection are performed as independent tests that use two separate portions of a precious sample. The sample can be entirely used up by either analysis. Therefore, we developed a new procedure involving partial lysis of a stimulant-containing blood sample followed by separation of the lysate into a precipitate for DNA typing and a liquid-phase fraction for methamphetamine detection. The method enables these two tests to be run in parallel using a single portion of sample. Samples were prepared by adding methamphetamine hydrochloride water solution to blood. Samples were lysed with Proteinase K in PBS at 56°C for 20min, cooled at -20°C after adding methanol, and then centrifuged at 15,000rpm. Based on the biopolymer-precipitating ability of alcohol, the precipitate was used for DNA typing and the liquid-phase fraction for methamphetamine detection. For DNA typing, the precipitate was dissolved and DNA was extracted, quantified, and subjected to STR analysis using the AmpFℓSTR® Identifiler® Plus PCR Amplification Kit. For methamphetamine detection, the liquid-phase fraction was evaporated with N2 gas after adding 20μL acetic acid and passed through an extraction column; the substances captured in the column were eluted with a solvent, derivatized, and quantitatively detected using gas chromatograph/mass spectrometry. This method was simple and could be completed in approximately 2h. Both DNA typing and methamphetamine detection were possible, which suggests that this method may be valuable for use in criminal investigations. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Suitability of shredded tyres as a substitute for a landfill leachate collection medium.
Park, Jae K; Edil, Tuncer B; Kim, Jae Y; Huh, Mock; Lee, Sung Ho; Lee, Jung Jun
2003-06-01
A series of tests were conducted to investigate the fate of heavy metals and gasoline components in a simulated landfill, consisting of a 30 cm thick clay liner and a leachate collection layer containing tyres as well as in two test cells installed in a landfill. Arsenic, selenium, mercury, barium, and lead concentrations were lower while zinc concentration was higher in the tank containing tyre-chips than the tank without tyre-chips. When samples were filtered, however, concentrations of zinc as well as other inorganics were lower in the tank containing tyre-chips, indicating that metals in the leachate exposed to tyre-chips travel more slowly in a subsurface environment due to filtering effect. In a test cell study, arsenic, cobalt, lead and nickel concentrations were lower in the cell containing tyre-chips than in the cell without tyre-chips, except iron and zinc. Both tests indicate that some inorganic contaminants are sorbed to tyre-chips. Gasoline components were also significantly sorbed by tyre-chips in field cell tests. Although tyre-chips are known to leach organic and inorganic contaminants, concentrations in field conditions will be lower than the reported experimental results since the tests were performed under worst-case scenarios. If tyre-chips are used in areas where contamination levels are high, then they can be used as a sorbent for environmental clean-up.
40 CFR 265.112 - Closure plan; amendment of plan.
Code of Federal Regulations, 2010 CFR
2010-07-01
... residues and contaminated containment system components, equipment, structures, and soils during partial... contaminated soils, methods for sampling and testing surrounding soils, and criteria for determining the extent of decontamination necessary to satisfy the closure performance standard; and (5) A detailed...
40 CFR 264.112 - Closure plan; amendment of plan.
Code of Federal Regulations, 2010 CFR
2010-07-01
... residues and contaminated containment system components, equipment, structures, and soils during partial... contaminated soils, methods for sampling and testing surrounding soils, and criteria for determining the extent of decontamination required to satisfy the closure performance standard; and (5) A detailed...
7 CFR 1773.42 - Clearing accounts.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Clearing accounts. The CPA's workpapers must contain an analysis of all clearing accounts. Based upon the CPA's determination of materiality, an appropriate sample of transactions should be selected for testing. The CPA's workpapers must document that transactions were reviewed for proper allocation between...
ERIC Educational Resources Information Center
Miller, Sandra K.
The individualized learning package for secondary consumer education deals with consumer buying as influenced by advertising. The teacher's section of the package contains a statement of purpose and instructional objectives. Equipment and materials (specific textbooks, audiovisual aids, and sources for sample post-test advertisements) needed for…
NASA Technical Reports Server (NTRS)
Kubat, Gregory
2016-01-01
This report provides a description and performance characterization of the large-scale, Relay architecture, UAS communications simulation capability developed for the NASA GRC, UAS in the NAS Project. The system uses a validated model of the GRC Gen5 CNPC, Flight-Test Radio model. Contained in the report is a description of the simulation system and its model components, recent changes made to the system to improve performance, descriptions and objectives of sample simulations used for test and verification, and a sampling and observations of results and performance data.
Effect of Environmental Factors on Sulfur Gas Emissions from Drywall
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maddalena, Randy
2011-08-20
Problem drywall installed in U.S. homes is suspected of being a source of odorous and potentially corrosive indoor pollutants. The U.S. Consumer Product Safety Commission's (CPSC) investigation of problem drywall incorporates three parallel tracks: (1) evaluating the relationship between the drywall and reported health symptoms; (2) evaluating the relationship between the drywall and electrical and fire safety issues in affected homes; and (3) tracing the origin and the distribution of the drywall. To assess the potential impact on human health and to support testing for electrical and fire safety, the CPSC has initiated a series of laboratory tests that providemore » elemental characterization of drywall, characterization of chemical emissions, and in-home air sampling. The chemical emission testing was conducted at Lawrence Berkeley National Laboratory (LBNL). The LBNL study consisted of two phases. In Phase 1 of this study, LBNL tested thirty drywall samples provided by CPSC and reported standard emission factors for volatile organic compounds (VOCs), aldehydes, reactive sulfur gases (RSGs) and volatile sulfur compounds (VSCs). The standard emission factors were determined using small (10.75 liter) dynamic test chambers housed in a constant temperature environmental chamber. The tests were all run at 25 C, 50% relative humidity (RH) and with an area-specific ventilation rate of {approx}1.5 cubic meters per square meter of emitting surface per hour [m{sup 3}/m{sup 2}/h]. The thirty samples that were tested in Phase 1 included seventeen that were manufactured in China in 2005, 2006 and 2009, and thirteen that were manufactured in North America in 2009. The measured emission factors for VOCs and aldehydes were generally low and did not differ significantly between the Chinese and North American drywall. Eight of the samples tested had elevated emissions of volatile sulfur-containing compounds with total RSG emission factors between 32 and 258 micrograms per square meter per hour [{micro}g/m{sup 2}/h]. The dominant sulfur containing compounds in the RSG emission stream were hydrogen sulfide with emission factors between 17-201 {micro}g/m{sup 2}/h, and sulfur dioxide with emission factors between 8-64 {micro}g/m{sup 2}/h. The four highest emitting samples also had a unique signature of VSC emissions including > 40 higher molecular weight sulfur-containing compounds although the emission rate for the VSCs was several orders of magnitude lower than that of the RSGs. All of the high emitting drywall samples were manufactured in China in 2005-2006. Results from Phase 1 provided baseline emission factors for drywall samples manufactured in China and in North America but the results exclude variations in environmental conditions that may exist in homes or other built structures, including various combinations of temperature, RH, ventilation rate and the influence of coatings such as texture and paints. The objective of Phase 2 was to quantify the effect of temperature and RH on the RSG emission factors for uncoated drywall, and to measure the effect of plaster and paint coatings on RSG emission factors from drywall. Additional experiments were also performed to assess the influence of ventilation rate on measured emission factors for drywall.« less
Final Report on Jobin Yvon Contained Inductively Coupled Plasma Emission Spectrometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pennebaker, F.M.
2003-03-17
A new Inductively Coupled Plasma -- Emission Spectrometer (ICP-ES) was recently purchased and installed in Lab B-147/151 at SRTC. The contained JY Model Ultima 170-C ICP-ES has been tested and compared to current ADS ICP-ES instrumentation. The testing has included both performance tests to evaluate instrumental ability, and the measurement of matrix standards commonly analyzed by ICP-ES at Savannah River. In developing operating procedures for this instrument, we have implemented the use of internal standards and off-peak background subtraction. Both of these techniques are recommended by EPA SW-846 ICP-ES methods and are common to current ICP-ES operations. Based on themore » testing and changes, the JY Model Ultima 170-C ICP-ES provides improved performance for elemental analysis of radioactive samples in the Analytical Development Section.« less
Influence of speech sample on perceptual rating of hypernasality.
Medeiros, Maria Natália Leite de; Fukushiro, Ana Paula; Yamashita, Renata Paciello
2016-07-07
To investigate the influence of speech sample of spontaneous conversation or sentences repetition on intra and inter-rater hypernasality reliability. One hundred and twenty audio recorded speech samples (60 containing spontaneous conversation and 60 containing repeated sentences) of individuals with repaired cleft palate±lip, both genders, aged between 6 and 52 years old (mean=21±10) were selected and edited. Three experienced speech and language pathologists rated hypernasality according to their own criteria using 4-point scale: 1=absence of hypernasality, 2=mild hypernasality, 3=moderate hypernasality and 4=severe hypernasality, first in spontaneous speech samples and 30 days after, in sentences repetition samples. Intra- and inter-rater agreements were calculated for both speech samples and were statistically compared by the Z test at a significance level of 5%. Comparison of intra-rater agreements between both speech samples showed an increase of the coefficients obtained in the analysis of sentences repetition compared to those obtained in spontaneous conversation. Comparison between inter-rater agreement showed no significant difference among the three raters for the two speech samples. Sentences repetition improved intra-raters reliability of perceptual judgment of hypernasality. However, the speech sample had no influence on reliability among different raters.
Schlottmann, Jamie L.; Funkhouser, Ron A.
1991-01-01
Chemical analyses of water from eight test holes and geophysical logs for nine test holes drilled in the Central Oklahoma aquifer are presented. The test holes were drilled to investigate local occurrences of potentially toxic, naturally occurring trace substances in ground water. These trace substances include arsenic, chromium, selenium, residual alpha-particle activities, and uranium. Eight of the nine test holes were drilled near wells known to contain large concentrations of one or more of the naturally occurring trace substances. One test hole was drilled in an area known to have only small concentrations of any of the naturally occurring trace substances.Water samples were collected from one to eight individual sandstone layers within each test hole. A total of 28 water samples, including four duplicate samples, were collected. The temperature, pH, specific conductance, alkalinity, and dissolved-oxygen concentrations were measured at the sample site. Laboratory determinations included major ions, nutrients, dissolved organic carbon, and trace elements (aluminum, arsenic, barium, beryllium, boron, cadmium, chromium, hexavalent chromium, cobalt, copper, iron, lead, lithium, manganese, mercury, molybdenum, nickel, selenium, silver, strontium, vanadium and zinc). Radionuclide activities and stable isotope (5 values also were determined, including: gross-alpha-particle activity, gross-beta-particle activity, radium-226, radium-228, radon-222, uranium-234, uranium-235, uranium-238, total uranium, carbon-13/carbon-12, deuterium/hydrogen-1, oxygen-18/oxygen-16, and sulfur-34/sulfur-32. Additional analyses of arsenic and selenium species are presented for selected samples as well as analyses of density and iodine for two samples, tritium for three samples, and carbon-14 for one sample.Geophysical logs for most test holes include caliper, neutron, gamma-gamma, natural-gamma logs, spontaneous potential, long- and short-normal resistivity, and single-point resistance. Logs for test-hole NOTS 7 do not include long- and short-normal resistivity, spontaneous-potential, or single-point resistivity. Logs for test-hole NOTS 7A include only caliper and natural-gamma logs.
Ramia, S; Sattar, S A
1980-03-01
There is mounting evidence for the waterborne transmission of diarrhea caused by rotaviruses. As a result, proper techniques are required for their recovery from samples of incriminated water. The combined efficiency of the talc-Celite technique and polyethylene glycol 6000 hydroextraction was, therefore, tested for this purpose, using Simian rotavirus SA-11 and MA-104 cells. Conditioning of the dechlorinated tap water samples was carried out by pH adjustment to 6.0 and the addition of Earle balanced salt solution to a final concentration of 1:100. Passage of a 1-liter volume of such a conditioned sample through a layer containing a mixture of talc (300 mg) and Celite 503 (100 mg) led to the adsorption of nearly 93% of the added SA-11 plaque-forming units. For the recovery of the layer-adsorbed virus, 3% beef extract and 1x tryptose phosphate broth were found to be superior to a variety of other eluents tested. When we tested 100-liter sample volumes, layers containing 1.2 g of talc and 0.4 g of Celite were employed. Virus elution was carried out with 100 ml of tryptose phosphate broth. The eluate was concentrated 10-fold by overnight (4 degrees C) hydroextraction with polyethylene glycol. With a total input virus of 7.0 x 10(5) and 1.4 x 10(2) plaque-forming units, the recoveries were about 71 and 59%, respectively.
Comparative testing of nondestructive examination techniques for concrete structures
NASA Astrophysics Data System (ADS)
Clayton, Dwight A.; Smith, Cyrus M.
2014-03-01
A multitude of concrete-based structures are typically part of a light water reactor (LWR) plant to provide foundation, support, shielding, and containment functions. Concrete has been used in the construction of nuclear power plants (NPPs) because of three primary properties, its inexpensiveness, its structural strength, and its ability to shield radiation. Examples of concrete structures important to the safety of LWR plants include containment building, spent fuel pool, and cooling towers. Comparative testing of the various NDE concrete measurement techniques requires concrete samples with known material properties, voids, internal microstructure flaws, and reinforcement locations. These samples can be artificially created under laboratory conditions where the various properties can be controlled. Other than NPPs, there are not many applications where critical concrete structures are as thick and reinforced. Therefore, there are not many industries other than the nuclear power plant or power plant industry that are interested in performing NDE on thick and reinforced concrete structures. This leads to the lack of readily available samples of thick and heavily reinforced concrete for performing NDE evaluations, research, and training. The industry that typically performs the most NDE on concrete structures is the bridge and roadway industry. While bridge and roadway structures are thinner and less reinforced, they have a good base of NDE research to support their field NDE programs to detect, identify, and repair concrete failures. This paper will summarize the initial comparative testing of two concrete samples with an emphasis on how these techniques could perform on NPP concrete structures.
A new sampler for stratified lagoon chemical and microbiological assessments.
McLaughlin, M R; Brooks, J P; Adeli, A
2014-07-01
A sampler was needed for a spatial and temporal study of microbial and chemical stratification in a large swine manure lagoon that was known to contain zoonotic bacteria. Conventional samplers were limited to collections of surface water samples near the bank or required a manned boat. A new sampler was developed to allow simultaneous collection of multiple samples at different depths, up to 2.3 m, without a manned boat. The sampler was tethered for stability, used remote control (RC) for sample collection, and accommodated rapid replacement of sterile tubing modules and sample containers. The sampler comprised a PVC pontoon with acrylic deck and watertight enclosures, for a 12 VDC gearmotor, to operate the collection module, and vacuum system, to draw samples into reusable autoclavable tubing and 250-mL bottles. Although designed primarily for water samples, the sampler was easily modified to collect sludge. The sampler held a stable position during deployment, created minimal disturbance in the water column, and was readily cleaned and sanitized for transport. The sampler was field tested initially in a shallow fresh water lake and subsequently in a swine manure treatment lagoon. Analyses of water samples from the lagoon tests showed that chemical and bacterial levels, pH, and EC did not differ between 0.04, 0.47, and 1.0 m depths, but some chemical and bacterial levels differed between winter and spring collections. These results demonstrated the utility of the sampler and suggested that future manure lagoon studies employ fewer or different depths and more sampling dates.
Development of fracture mechanics data for two hydrazine APU turbine wheel materials
NASA Technical Reports Server (NTRS)
Curbishley, G.
1975-01-01
The effects of high temperature, high pressure ammonia were measured on the fracture mechanics and fatigue properties of Astroloy and Rene' 41 turbine wheel materials. Also, the influence of protective coatings on these properties was investigated. Specimens of forged bar stock were subjected to LCF and HCF tests at 950 K (1250 F) and 3.4 MN/sq m (500 psig) pressure, in ammonia containing about 1.5 percent H2O. Aluminized samples (Chromizing Company's Al-870) and gold plated test bars were compared with uncoated specimens. Comparison tests were also run in air at 950 K (1250 F), but at ambient pressures. K sub IE and K sub TH were determined on surface flawed specimens in both the air and ammonia in both uncoated and gold plated conditions. Gold plated specimens exhibited better properties than uncoated samples, and aluminized test bars generally had lower properties. The fatigue properties of specimens tested in ammonia were higher than those tested in air, yet the K sub TH values of ammonia tested samples were lower than those tested in air. However, insufficient specimens were tested to develop significant design data.
Antibacterial performance of nano polypropylene filter media containing nano-TiO2 and clay particles
NASA Astrophysics Data System (ADS)
Shafiee, Sara; Zarrebini, Mohammad; Naghashzargar, Elham; Semnani, Dariush
2015-10-01
Disinfection and elimination of pathogenic microorganisms from liquid can be achieved by filtration process using antibacterial filter media. The advent of nanotechnology has facilitated the introduction of membranes consisting of nano-fiber in filtration operations. The melt electro-spun fibers due to their extremely small diameters are used in the production of this particular filtration medium. In this work, antibacterial polypropylene filter medium containing clay particles and nano-TiO2 were made using melt electro-spun technology. Antibacterial performance of polypropylene nano-filters was evaluated using E. coli bacteria. Additionally, filtration efficiency of the samples in terms fiber diameter, filter porosity, and fiber distribution using image processing technique was determined. Air permeability and dust aerosol tests were conducted to establish the suitability of the samples as a filter medium. It was concluded that as far as antibacterial property is concerned, nano-fibers filter media containing clay particles are preferential to similar media containing TiO2 nanoparticles.
Motlagh, N Valipoor; Mosavian, M T Hamed; Mortazavi, S A; Tamizi, A
2012-01-01
In this research, the effects of low-density polyethylene (LDPE) packages containing micrometer-sized silver particles (LDPE-Ag) on microbial and sensory factors of dried barberry were investigated in comparison with the pure LDPE packages. LDPE-Ag packages with 1% and 2% concentrations of silver particles statistically caused a decrease in the microbial growth of barberry, especially in the case of mold and total bacteria count, compared with the pure LDPE packages. The taste, aroma, appearance, and total acceptance were evaluated by trained panelists using the 9-point hedonic scale. This test showed improvement of all these factors in the samples related to packages containing 1% and 2% concentrations of silver particles in comparison with other samples. Low-density polyethylene package containing micrometer-sized silver particles had beneficial effects on the sensory and microbial quality of barberry when compared with normal packing material. © 2011 Institute of Food Technologists®
Results of Performance Tests Performed on the John Watts WW Casing Connection on 7" Pipe
DOE Office of Scientific and Technical Information (OSTI.GOV)
John D. Watts
2000-02-01
Stress Engineering Services (SES) was contracted by Mr. John Watts to test his ''WW'' threaded connection developed for oilfield oil and gas service. This work was a continuation of testing performed by SES as reported in August of 1999. The connection design tested was identified as ''WW''. The samples were all integral (no coupled connections) and contained a wedge thread form with 90{sup o} flank angles relative to the pipe centerline. The wedge thread form is a variable width thread that primarily engages on the flanks. This thread form provides very high torque capacity and good stabbing ability and makeup.more » The test procedure selected for one of the samples was the newly written ISO 13679 procedure for full scale testing of casing and tubing connections, which is currently going through the ISO acceptance process. The ISO procedure requires a variety of tests that includes makeup/breakout testing, internal gas sealability/external water sealability testing with axial tension, axial compression, bending, internal gas thermal cycle tests and limit load (failure) tests. This test procedure was performed with one sample. Four samples were tested to failure. Table 1 contains a summary of the tasks performed by SES. The project started with the delivery of test samples by Mr. Watts. Pipe from the previous round of tests was used for the new samples. Figure 1 shows the structural and sealing results relative to the pipe body. Sample 1 was used to determine the torque capacity of the connection. Torque was applied to the capacity of SES's equipment which was 28,424 ft-lbs. From this, an initial recommended torque range of 7,200 to 8,800 ft-lbs. was selected. The sample was disassembled and while there was no galling observed in the threads, the end of the pin had collapsed inward. Sample 2 received three makeups. Breakouts 1 and 2 also had collapsing of the pin end, with no thread galling. From these make/breaks, it was decided to reduce the amount of lubricant applied to the connection by applying it to the box or pin only and reducing the amount applied. Samples 3 and 4 received one makeup only. Sample 5 initially received two make/breaks to test for galling resistance before final makeup, No galling was observed. Later, three additional make/breaks were performed with no pin end collapse and galling over 1/2 a thread occurring on one of the breakouts. During the make/break tests, the stabbing and hand tight makeup of the WW connection was found to be very easy and trouble free. There was no tendency to crossthread, even when stabbed at an angle, and it screwed together very smoothly up to hand tight. During power tight makeup, there was no heat generated in the box (as checked by hand contact) and no jerkiness associated with any of the makeups or breakouts. Sample 2 was tested in pure compression. The maximum load obtained was 1,051 kips and the connection was beginning to significantly deform as the sample buckled. Actual pipe yield was 1,226 kips. Sample 3 was capped-end pressure tested to failure. The capped-end yield pressure of the pipe was 16,572 psi and the sample began to leak at 12,000 psi. Sample 4 was tested in pure tension. The maximum load obtained was 978 kips and the connection failed by fracture at the pin critical section. Actual pipe yield was 1,226 kips. Sample 5 was tested in combined tension/compression and internal gas pressure. The sample was assembled, setup and tested four times. The first time was with a torque of 7,298 ft-lbs and the connection leaked halfway to ISO Load Point 2 with loads of 693 kips and 4,312 psi. The second time the torque was increased to 14,488 ft-lbs and a leak occurred at 849 kips and 9,400 psi, which was ISO Load Point 2. The third time the makeup torque was again increased, to 20,456 ft-lbs, and a leak occurred at 716 kips and 11,342 psi, ISO Load Point 4. The fourth test was with the same torque as before, 20,617 ft-lbs, and the connection successfully tested up to load step 56, ISO Load Point 6 (second round) before leaking at 354 kips and 11,876 psi. At this point, time and funds prevented additional testing to be performed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark, Scarlett R.; Leonard, Keith J.
The goal of the Mechanisms of Irradiation Assisted Stress Corrosion Cracking (IASCC) task in the LWRS Program is to conduct experimental research into understanding how multiple variables influence the crack initiation and crack growth in materials subjected to stress under corrosive conditions. This includes understanding the influences of alloy composition, radiation condition, water chemistry and metallurgical starting condition (i.e., previous cold work or heat treatments and the resulting microstructure) has on the behavior of materials. Testing involves crack initiation and growth testing on irradiated specimens of single-variable alloys in simulated Light Water Reactor (LWR) environments, tensile testing, hardness testing, microstructuralmore » and microchemical analysis, and detailed efforts to characterize localized deformation. Combined, these single-variable experiments will provide mechanistic understanding that can be used to identify key operational variables to mitigate or control IASCC, optimize inspection and maintenance schedules to the most susceptible materials/locations, and, in the long-term, design IASCC-resistant materials. In support of this research, efforts are currently underway to arrange shipment of “free” high fluence austenitic alloys available through Électricité de France (EDF) for post irradiation testing at the Oak Ridge National Laboratory (ORNL) and IASCC testing at the University of Michigan. These high fluence materials range in damage values from 45 to 125 displacements per atom (dpa). The samples identified for transport to the United States, which include nine, no-cost, 304, 308 and 316 tensile bars, were relocated from the Research Institute of Atomic Reactors (RIAR) in Dimitrovgrad, Ulyanovsk Oblast, Russia, and received at the Halden Reactor in Halden, Norway, on August 23, 2016. ORNL has been notified that a significant amount of work is required to prepare the samples for further shipment to Oak Ridge, Tennessee. The preliminary work for sample shipment between Halden and Oak Ridge includes fabrication of an inner cask sample container, decontamination and preparation of a Type A container, preparation of new activity calculations, all necessary paperwork, and handling. ORNL will continue to work to track progress of sample preparation and shipment status, and to work toward an agreement that covers material shipping costs between the Halden Reactor and the Oak Ridge National Laboratory.« less
Appannanavar, Suma B; Biswal, Manisha; Rajkumari, Nonika; Mohan, Balvinder; Taneja, Neelam
2013-01-01
Urine culture is a gold standard in the diagnosis of urinary tract infection. Clean catch midstream urine collection and prompt transportation is essential for appropriate diagnosis. Improper collection and delay in transportation leads to diagnostic dilemma. In developing countries, higher ambient temperatures further complicate the scenario. Here, we have evaluated the role of boric acid as a preservative for urine samples prior to culture in female patients attending outpatient department at our center. Consecutive 104 urine samples were cultured simultaneously in plain uricol (Control-C) and boric acid containing tubes from Becton Dickinson urine culture kit (Boric acid group-BA). In the real-time evaluation, we found that in almost 57% (59/104) of the urine samples tested, it was more effective in maintaining the number of the organisms as compared to samples in the container without any preservative. Our in vitro study of simulated urine cultures revealed that urine samples could be kept up to 12 h before culture in the preservative without any inhibitory effect of boric acid. Though the use of boric acid kit may marginally increase the initial cost but has indirect effects like preventing delays in treatment and avoidance of false prescription of antibiotics. If the man-hours spent on repeat investigations are also taken into consideration, then the economic cost borne by the laboratory would also decrease manifold with the use of these containers.
Simulation-based Extraction of Key Material Parameters from Atomic Force Microscopy
NASA Astrophysics Data System (ADS)
Alsafi, Huseen; Peninngton, Gray
Models for the atomic force microscopy (AFM) tip and sample interaction contain numerous material parameters that are often poorly known. This is especially true when dealing with novel material systems or when imaging samples that are exposed to complicated interactions with the local environment. In this work we use Monte Carlo methods to extract sample material parameters from the experimental AFM analysis of a test sample. The parameterized theoretical model that we use is based on the Virtual Environment for Dynamic AFM (VEDA) [1]. The extracted material parameters are then compared with the accepted values for our test sample. Using this procedure, we suggest a method that can be used to successfully determine unknown material properties in novel and complicated material systems. We acknowledge Fisher Endowment Grant support from the Jess and Mildred Fisher College of Science and Mathematics,Towson University.
Hu, Ai-Peng; Liu, Yu-Lan; Shi, Long-Kai
2016-09-01
Seven different phthalic acid esters (PAEs) were quantified in 124 samples of 16 types of oilseeds from China using a simplified GC-MS method. Di-2-ethylhexyl phthalate and di-n-butyl phthalate were found in all tested oilseed samples. Each made a high contribution to the summed total PAEs. Total PAE concentrations in 124 oilseeds ranged from 0.14 to 3.05 mg kg(-1), and the mean was 0.99 mg kg(-1). Mandulapalka (Cyperus esculentus) samples were the most severely contaminated among all the tested specimens; maize germ samples were least contaminated. Di-n-octyl phthalate and butylbenzyl phthalate were not detected in 12 and five types of oilseeds, respectively. Only eight samples contained all seven analytes. No difference was observed between woody oil-bearing plant and herbaceous oil-bearing plant in terms of PAEs content.
Tsujikawa, Kenji; Saiki, Fujio; Yamamuro, Tadashi; Iwata, Yuko T; Abe, Ryoji; Ohashi, Hiroyuki; Kaigome, Rena; Yamane, Kyosuke; Kuwayama, Kenji; Kanamori, Tatsuyuki; Inoue, Hiroyuki
2016-09-01
We developed a novel immunoassay for herbal cannabis based on a new immunoassay principle that uses Ultra Quenchbody ("UQ-body"), a recombinant antibody Fab fragment fluorolabeled at the N-terminal regions. When the antigen binds to anti-Δ(9)-tetrahydrocannabinol (THC) UQ-body, the fluorescence intensity (FI) decreases. The analytical conditions of the immunoassay were optimized based on the FI reduction rate (FIRR). Following are the steps in the final analytical procedure: (1) 10mg of samples were extracted with 1ml of a 60:40 mixture of methanol and phosphate-buffered saline (PBS); (2) the extract was filtered through a centrifugal 0.2-μm polytetrafluoroethylene membrane filter; (3) the filtrate was diluted 100 times with extraction solvent; (4) 6-μl diluted solution was mixed with 19-μl PBS and 75-μl UQ-body solution; and (5) FIRR was measured under 275-mV excitation light. Herbal cannabis samples containing ≥4.0-mg/g THC gave FIRRs of ≥5.2%. FIRRs of negative samples (cigarette, tea, spice, and so-called "synthetic marijuana") were ≤3.1%. When setting the FIRR threshold to 5.0%, cannabis samples containing ≥4.0-mg/g THC were correctly judged as positive without being affected by false positives caused by the negative samples. This detection limit was lower than total THC level (10-200mg/g) in most herbal cannabis samples seized in Japan. In seven of the 10 cannabis samples, the results of the UQ-body test were comparable with those of the Duquenois-Levine test. Thus, the UQ-body-based immunoassay is presumed to be an effective and objective drug screening method for herbal cannabis; however, to show the true usefulness, it is necessary to test a number of real case samples in the field situation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
García-González, Elena; Aramendía, Maite; Álvarez-Ballano, Diego; Trincado, Pablo; Rello, Luis
2016-04-01
Endogenous antibodies (EA) may interfere with immunoassays, causing erroneous results for hormone analyses. As (in most cases) this interference arises from the assay format and most immunoassays, even from different manufacturers, are constructed in a similar way, it is possible for a single type of EA to interfere with different immunoassays. Here we describe the case of a patient whose serum sample contains EA that interfere several hormones tests. We also discuss the strategies deployed to detect interference. Over a period of four years, a 30-year-old man was subjected to a plethora of laboratory and imaging diagnostic procedures as a consequence of elevated hormone results, mainly of pituitary origin, which did not correlate with the overall clinical picture. Once analytical interference was suspected, the best laboratory approaches to investigate it were sample reanalysis on an alternative platform and sample incubation with antibody blocking tubes. Construction of an in-house 'nonsense' sandwich assay was also a valuable strategy to confirm interference. In contrast, serial sample dilutions were of no value in our case, while polyethylene glycol (PEG) precipitation gave inconclusive results, probably due to the use of inappropriate PEG concentrations for several of the tests assayed. Clinicians and laboratorians must be aware of the drawbacks of immunometric assays, and alert to the possibility of EA interference when results do not fit the clinical pattern.
Holloman, Jessica L; Mauriello, Sally M; Pimenta, Luiz; Arnold, Roland R
2015-01-01
Aerosols and spatter are concerns in health care owing to their potential adverse health effects. The Isolite illuminated isolation system (Isolite Systems) and a saliva ejector were compared for aerosol and spatter reduction during and after ultrasonic scaling. Fifty participants were randomized to control (n = 25, saliva ejector) or test (n = 25, Isolite) groups and received a prophylaxis with an ultrasonic scaler. Aerosols were collected in a petri dish containing transport media, dispersed, and plated to anaerobic blood agar to determine colony-forming units (CFUs). The authors analyzed the data using a t test. No significant difference occurred between groups in aerosol and spatter reduction (P = .25). Mean (standard deviation) of log10 CFUs per milliliter collected during ultrasonic scaling in the control and test groups were 3.61 (0.95) and 3.30 (0.88), respectively. All samples contained α-hemolytic streptococci, and many samples contained strictly oral anaerobes. A significant amount of contamination occurred during ultrasonic scaling in both groups, as indicated by high numbers of CFUs and the identification of strictly oral anaerobes in all plates. Neither device reduced aerosols and spatter effectively, and there was no significant difference in reduction between the 2 devices. Additional measures should be taken with these devices to reduce the likelihood of disease transmission. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.
1981-01-01
incubated for an additional 10 min at 22°C. Immune rene test tubes. Samples were withdrawn aseptically complexes were collected by centrifugation at 3.000... tested imme- of assay buffer, and the final pellets were counted with diately in an assay, and the other was frozen at -70°C. a Beckman Biogamma counter... tested before and after activation immunoadsorbent for immune complexes containing with urea and dithiothreitol (13). Enzyme neutraliza
Microbial contamination of water-soaked cotton gauze and its cause.
Oie, S; Yoshida, H; Kamiya, A
2001-01-01
Seven in-use cotton gauze samples and three cotton balls soaked in sterile distilled water in canisters were investigated 7 days after they were prepared in hospital. All samples were contaminated with bacteria including 10(6) to 10(7) colony forming units/ml of Pseudomonas aeruginosa. In vitro viability tests using cotton gauze and cotton balls soaked in sterile distilled water revealed rapid proliferation of P. aeruginosa, Serratia marcescens and Candida albicans. Since the cotton gauze and the cotton balls were soaked in water containing nutrients, such as protein and glucose, these materials may be readily contaminated with bacteria including P. aeruginosa. Thus, when using cotton gauze and cotton balls containing water, microbial contamination should be expected.
Narayana, Sai Sathya; Deepa, Vinoth Kumar; Ahamed, Shafie; Sathish, Emmanuel Solomon; Meyappan, R; Satheesh Kumar, K S
2014-01-01
The objective of this study is to investigate the efficacy of bioactive glass containing product on remineralization of artificial induced carious enamel lesion and to compare its efficiency with other remineralization products using an in-vitro pH cycling method. The null hypothesis tested was bioactive glass has no effect on enamel remineralization. A total of 20 enamel samples of human molar teeth were subjected to artificial caries lesion formation using pH cycling method and was verified using high resolution scanning electron microscope (HRSEM). Each demineralized sample was then divided into five test groups each containing twenty. Group A - Bioactive glass (SHY-NM), Group B - Fluoride tooth paste (Amflor), Group C - CPP-ACP (Tooth mousse), Group D - CPP-ACPF (Tooth mousse plus), Group E - control. All the test groups were exposed to the pH cycling regime, the remineralizing agents were applied for 10 min except control. After 10 days period, the entire test groups were evaluated with HRSEM and quantitative assessment by energy dispersive X-ray spectroscopy. The obtained data was analyzed statistically using one-way ANOVA, Student's t-test and Tukey's multiple comparison tests. P ≤ 0.05 was considered to be significant. Rejection of the null hypothesis and highlights the concept of biomimetic bioactive glass as an effective remineralizing agent. To focus on the importance of minimal invasive treatment on incipient carious lesion by remineralization.
Puri, Basant K; Egan, Mary; Wallis, Fintan; Jakeman, Philip
2018-03-22
To investigate the repeatability of proton magnetic resonance spectroscopy in the in vivo measurement of human cerebral levels of choline-containing compounds (Cho). Two consecutive scans were carried out in six healthy resting subjects at a magnetic field strength of 1.5 T. On each occasion, neurospectroscopy data were collected from 64 voxels using the same 2D chemical shift imaging (CSI) sequence. The data were analyzed in the same way, using the same software, to obtain the values for each voxel of the ratio of Cho to creatine. The Wilcoxon related-samples signed-rank test, coefficient of variation (CV), repeatability coefficient (RC), and intraclass correlation coefficient (ICC) were used to assess the repeatability. The CV ranged from 2.75% to 33.99%, while the minimum RC was 5.68%. There was excellent reproducibility, as judged by significant ICC values, in 26 voxels. Just three voxels showed significant differences according to the Wilcoxon related-samples signed-rank test. It is therefore concluded that when CSI multivoxel proton neurospectroscopy is used to measure cerebral choline-containing compounds at 1.5 T, the reproducibility is highly acceptable.
Visual detection of particulates in x-ray images of processed meat products
NASA Astrophysics Data System (ADS)
Schatzki, Thomas F.; Young, Richard; Haff, Ron P.; Eye, J.; Wright, G.
1996-08-01
A study was conducted to test the efficacy of detecting particulate contaminants in processed meat samples by visual observation of line-scanned x-ray images. Six hundred field- collected processed-product samples were scanned at 230 cm2/s using 0.5 X 0.5-mm resolution and 50 kV, 13 mA excitation. The x-ray images were image corrected, digitally stored, and inspected off-line, using interactive image enhancement. Forty percent of the samples were spiked with added contaminants to establish the visual recognition of contaminants as a function of sample thickness (1 to 10 cm), texture of the x-ray image (smooth/textured), spike composition (wood/bone/glass), size (0.1 to 0.4 cm), and shape (splinter/round). The results were analyzed using a maximum likelihood logistic regression method. In packages less than 6 cm thick, 0.2-cm-thick bone chips were easily recognized, 0.1-cm glass splinters were recognized with some difficulty, while 0.4-cm-thick wood was generally missed. Operational feasibility in a time-constrained setting was confirmed. One half percent of the samples arriving from the field contained bone slivers > 1 cm long, 1/2% contained metallic material, while 4% contained particulates exceeding 0.3 cm in size. All of the latter appeared to be bone fragments.
Image parameters for maturity determination of a composted material containing sewage sludge
NASA Astrophysics Data System (ADS)
Kujawa, S.; Nowakowski, K.; Tomczak, R. J.; Boniecki, P.; Dach, J.
2013-07-01
Composting is one of the best methods for management of sewage sludge. In a reasonably conducted composting process it is important to early identify the moment in which a material reaches the young compost stage. The objective of this study was to determine parameters contained in images of composted material's samples that can be used for evaluation of the degree of compost maturity. The study focused on two types of compost: containing sewage sludge with corn straw and sewage sludge with rapeseed straw. The photographing of the samples was carried out on a prepared stand for the image acquisition using VIS, UV-A and mixed (VIS + UV-A) light. In the case of UV-A light, three values of the exposure time were assumed. The values of 46 parameters were estimated for each of the images extracted from the photographs of the composted material's samples. Exemplary averaged values of selected parameters obtained from the images of the composted material in the following sampling days were presented. All of the parameters obtained from the composted material's images are the basis for preparation of training, validation and test data sets necessary in development of neural models for classification of the young compost stage.
Effects of Storage on Sediment Toxicity, Bioaccumulation Potential, and Chemistry
1991-01-01
and tested with organisms used by the US Army Engineer District, New York. Test sedi- ments were collected from Westchester Creek (WC), Gowanus Bay ...Ms. Carole Brown, ERSD, obtained the sediment samples. Dr. Eric Crecelius, Battelle Pacific Northwest Laboratories, Sequim , WA, coordinated chemical...other sites, suspected of containing contam- inated sediment, were Westchester Creek (WC), Gowanus Bay (GB), and Arthur Kill (AK), all located in
Harris, Michael A; Beenken, Karen E; Smeltzer, Mark S; Haggard, Warren O; Jennings, J Amber
2017-07-01
Phosphatidylcholine coatings have been shown to elute antibiotics for several days. A recently developed biofilm inhibitor, cis-2-decenoic acid (C2DA), has been shown to exhibit synergistic activity with several common antibiotics. This study aims to evaluate the effectiveness of C2DA and amikacin dual drug delivery from a phosphatidylcholine coating. (1) What are the in vitro elution profiles of amikacin and C2DA from phosphatidylcholine-coated coupons in incubated phosphate-buffered saline? (2) Does the presence of C2DA in eluate samples lower the amount of amikacin needed for bacterial inhibition in overnight bacterial turbidity assays? (3) Does addition of amikacin and C2DA result in decreased colony-forming units (CFUs) on wire implants and bone when compared with phosphatidylcholine coatings alone in a mouse model of periprosthetic joint infection? Effects of loading concentrations were assessed during 7-day in vitro elution studies for coatings containing all mixtures of 0%, 5%, 15%, and 25% wt of amikacin and C2DA (n = 4) through quantitative high-performance liquid chromatography concentration determination and plotting concentration eluted over time. Antimicrobial activity was assessed by overnight turbidity testing of elution study samples against Staphylococcus aureus or Pseudomonas aeruginosa. In vivo efficacy was assessed using phosphatidylcholine-coated wire implants in a murine (mouse) model of infection (n = 3). Wire implants were coated with phosphatidylcholine containing no antimicrobials, amikacin alone, C2DA alone, or amikacin and C2DA and then inserted into the intramedullary femur of each mouse and inoculated with S aureus. The number of viable bacterial colonies on the implant surface and in the surrounding bone was determined after 1 week with the goal of achieving complete bacterial clearance. Total viable CFU count and proportion of samples achieving complete clearance were compared between groups. Elution samples showed a burst response of amikacin and C2DA for 1 to 2 days with C2DA release continuing at low levels through Day 4. All tested eluate samples inhibited P aeruginosa. Samples from coatings containing 25% amikacin or 15% amikacin and any amount of C2DA were able to inhibit S aureus formation, but all coatings with 5% amikacin or 15% amikacin but no C2DA were not inhibitory. All in vivo treatment groups achieved complete bacterial clearance on the wire implant, and the C2DA alone and amikacin alone coatings cleared all CFUs in bone (pin: phosphatidylcholine only one of three; amikacin three of three, C2DA three of three, amikacin + C2DA three of three, p = 0.04 [Fisher's exact test]; bone: coating only: zero of three; amikacin: three of three; C2DA; three of three; C2DA + amikacin: one of three; p = 0.03 [Fisher's exact test]). Phosphatidylcholine coatings elute antimicrobials in vitro under infinite sink conditions for up to 4 days in phosphate-buffered saline and were able to reduce bacterial colonies in a preliminary in vivo model. Turbidity testing with eluate samples containing varying amounts of C2DA and amikacin agrees with previous studies showing synergy between them. Used as an adjunctive to systemic therapy, C2DA-loaded phosphatidylcholine coatings have potential value as a prophylactic infection prevention measure. Future studies may include different antibiotics, animal studies with larger sample sizes and more controls, and advanced coating delivery methods.
Investigation of Comfort Properties of Knitted Denim
NASA Astrophysics Data System (ADS)
Akbar, Abdul R.; Su, Siwei; Khalid, Junaid; Cai, Yingjie; Lin, Lina
2017-12-01
Knitted denim was designed by using cross terry structure on circular knitting machine. Knitted denim looks like a denim fabric which has visual appearance like woven denim. Two type of cross terry structure 2/1 and 3/1 were used which gives twill effect with 2 and 3 floats respectively. Four types of materials, cotton, polyester, flax and polypropylene were used. With four materials and two structural combinations 8 samples were produced. Comfort properties of knitted denim including moisture management, air permeability, thermal, and bursting strength were tested. For checking the inherent anti-microbial property of materials anti-microbial test was also applied. Samples containing flax and polyester were found with best results and not even a single sample was found anti-microbial.
Chemistry with Inexpensive Materials: Spray Bottles and Plastic Bags.
ERIC Educational Resources Information Center
Zoltewicz, Susan
1993-01-01
Presents eight chemistry activities that are interesting and involve simple, easily available materials. Topics include mystery writing, valentine hearts, flame tests, evaporation race, buoyancy versus mass, determination of relative masses of gases, mole sample container, and cold and hot packs. (DDR)
42 CFR 493.917 - Parasitology.
Code of Federal Regulations, 2011 CFR
2011-10-01
... purposes— (1) Those that determine the presence or absence of parasites by direct observation (wet mount... certified in the subspecialty of parasitology for identification; (2) Those that identify parasites using... designee for on-site testing. An annual program must include samples that contain parasites that are...
7 CFR 1773.42 - Clearing accounts.
Code of Federal Regulations, 2011 CFR
2011-01-01
... § 1773.42 Clearing accounts. The CPA's workpapers must contain an analysis of all clearing accounts. Based upon the CPA's determination of materiality, an appropriate sample of transactions should be selected for testing. The CPA's workpapers must document that transactions were reviewed for proper...
7 CFR 1773.42 - Clearing accounts.
Code of Federal Regulations, 2012 CFR
2012-01-01
... § 1773.42 Clearing accounts. The CPA's workpapers must contain an analysis of all clearing accounts. Based upon the CPA's determination of materiality, an appropriate sample of transactions should be selected for testing. The CPA's workpapers must document that transactions were reviewed for proper...
7 CFR 1773.42 - Clearing accounts.
Code of Federal Regulations, 2010 CFR
2010-01-01
... § 1773.42 Clearing accounts. The CPA's workpapers must contain an analysis of all clearing accounts. Based upon the CPA's determination of materiality, an appropriate sample of transactions should be selected for testing. The CPA's workpapers must document that transactions were reviewed for proper...
7 CFR 1773.42 - Clearing accounts.
Code of Federal Regulations, 2013 CFR
2013-01-01
... § 1773.42 Clearing accounts. The CPA's workpapers must contain an analysis of all clearing accounts. Based upon the CPA's determination of materiality, an appropriate sample of transactions should be selected for testing. The CPA's workpapers must document that transactions were reviewed for proper...
Herpes viral culture of lesion
... grow in the laboratory dish and the skin sample used in the test did not contain any herpes virus. Be aware that a normal (negative) culture does not always mean that you do not have a herpes infection or have not had one in the past.
Veršilovskis, Aleksandrs; Bartkevičs, Vadims
2012-05-01
Sterigmatocystin (STC) is a carcinogenic and mutagenic mycotoxin produced by fungi of many Aspergillus species. The aim of this research was to test the stability of STC during the bread making process and to check bread samples from the Latvian market for STC contamination, using a previously developed electrospray positive ionisation (ESI(+)) liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. Wheat grain naturally contaminated with STC was used for bread baking. STC was found to be stable during the bread-making process. In the food survey 17% of the analysed breads were positive for STC, with concentration levels of 2-7 μg kg(-1). One out of six rye bread samples, one out of nine rye-wheat bread samples and three out of 14 wheat bread samples were contaminated with STC. Four out of five contaminated samples contained whole grains as the main ingredient. We conclude that whole grain bread may be a possible source of STC, although even STC-positive bread samples identified in this study contained quite low toxin levels.
Use of individual containers for prostate biopsy samples: Do we gain diagnostic performance?
Panach-Navarrete, J; García-Morata, F; Valls-González, L; Martínez-Jabaloyas, J M
2016-05-01
Prostate cores from transrectal biopsies are usually sent in separate vials for pathological processing. Although this is a common practice, there are controversial studies on its usefulness. We wanted to compare the rate of prostate cancer diagnosis between processing samples in 2 containers and processing them in individual containers to see if there are differences. Our secondary objective was to check the rate of diagnosis of various tumour subtypes in each of the 2 groups. A retrospective observational study was conducted of 2,601 cases of prostate biopsies. Ten cores were extracted in each biopsy. We divided the sample into 2 groups: biopsies sent in 2 containers to the department of pathology (left and right lobes) or sent in 10 (one for each cylinder), according to the different criteria used in our centre in the past. We then classified the cases according to the absence of neoplasia, insignificant tumour (involvement of just 1 cylinder, <5%, Gleason score<7), Gleason 6 or Gleason≥7. A bivariate statistical analysis was performed using the chi-squared test. A total of 1,777 participants were included in the 2-container group, and 824 were included in the 10-container group. We diagnosed a rate of 32.4% of cancers in the 2-container group and 40% in the 10-container group, a difference that was statistically significant (P<.001). The insignificant carcinomas were diagnosed more often in the 2-container group than in the 10-container group (6.4% vs. 4.3%, respectively; P=.03). Samples with a Gleason score of 6 were diagnosed more often in the 10-container group than in the 2-container group (11.9% vs. 8.1%, respectively; P=.002). The same occurred with the Gleason score≥7 (23.8% in the 10-container group vs. 17.9% in the 2-container group; P<.001). We diagnosed more prostate cancers when sending biopsied cores in individual containers. Once the procedure was conducted, we also observed in our series a reduction in the diagnoses of insignificant carcinoma to the detriment of an increased diagnosis of not insignificant carcinomas. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
Long-term ecological effects of exposure to uranium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanson, W.C.; Miera, F.R. Jr.
1976-03-01
The consequences of releasing natural and depleted uranium to terrestrial ecosystems during development and testing of depleted uranium munitions were investigated. At Eglin Air Force Base, Florida, soil at various distances from armor plate target butts struck by depleted uranium penetrators was sampled. The upper 5 cm of soil at the target bases contained an average of 800 ppM of depleted uranium, about 30 times as much as soil at 5- to 10-cm depth, indicating some vertical movement of depleted uranium. Samples collected beyond about 20 m from the targets showed near-background natural uranium levels, about 1.3 +- 0.3 ..mu..g/gmore » or ppM. Two explosives-testing areas at the Los Alamos Scientific Laboratory (LASL) were selected because of their use history. E-F Site soil averaged 2400 ppM of uranium in the upper 5 cm and 1600 ppM at 5-10 cm. Lower Slobovia Site soil from two subplots averaged about 2.5 and 0.6 percent of the E-F Site concentrations. Important uranium concentration differences with depth and distance from detonation points were ascribed to the different explosive tests conducted in each area. E-F Site vegetation samples contained about 320 ppM of uranium in November 1974 and about 125 ppM in June 1975. Small mammals trapped in the study areas in November contained a maximum of 210 ppM of uranium in the gastrointestinal tract contents, 24 ppM in the pelt, and 4 ppM in the remaining carcass. In June, maximum concentrations were 110, 50, and 2 ppM in similar samples and 6 ppM in lungs. These data emphasized the importance of resuspension of respirable particles in the upper few millimeters of soil as a contamination mechanism for several components of the LASL ecosystem.« less
Fortpied, Juliette; Wauters, Florence; Rochart, Christelle; Hermand, Philippe; Hoet, Bernard; Moniotte, Nicolas; Vojtek, Ivo
2018-01-01
ABSTRACT Accidental exposure of a vaccine containing an aluminum-salt adjuvant to temperatures below 0°C in the cold chain can lead to freeze damage. Our study evaluated the potential for freeze damage in a licensed aluminum-salt-containing protein-D-conjugated pneumococcal vaccine (PHiD-CV; Synflorix, GSK) in conditions that included static storage, single subzero-temperature excursions, and simulated air-freight transportation. Several parameters were assessed including freezing at subzero temperatures, aluminum-salt-particle size, antigen integrity and immunogenicity in the mouse. The suitability of the WHO's shake test for identifying freeze-damaged vaccines was also assessed. During subzero-temperature excursions, the mean temperatures at which PHiD-CV froze (−16.7°C to −18.1°C) appeared unaffected by the type of vaccine container (two-dose or four-dose vial, or single-dose syringe), vaccine batch, rotational agitation, or the rate of temperature decline (−0.5 to −10°C/hour). At constant subzero temperature and in simulated air-freight transportation, the freezing of PHiD-CV appeared to be promoted by vibration. At −5°C, no PHiD-CV sample froze in static storage (>1 month), whereas when subjected to vibration, a minority of samples froze (7/21, 33%) within 18 hours. At −8°C with vibration, nearly all (5/6, 83%) samples froze. In these vibration regimes, the shake test identified most samples that froze (10/12, 93%) except two in the −5°C regime. Nevertheless, PHiD-CV-antigen integrity appeared unaffected by freezing up to −20°C or by vibration. And although aluminum-salt-particle size was increased only by freezing at −20°C, PHiD-CV immunogenicity appeared only marginally affected by freezing at −20°C. Therefore, our study supports the use of the shake test to exclude freeze-damaged PHiD-CV in the field. PMID:29337646
Tian, Hai-Qing; Wang, Chun-Guang; Zhang, Hai-Jun; Yu, Zhi-Hong; Li, Jian-Kang
2012-11-01
Outlier samples strongly influence the precision of the calibration model in soluble solids content measurement of melons using NIR Spectra. According to the possible sources of outlier samples, three methods (predicted concentration residual test; Chauvenet test; leverage and studentized residual test) were used to discriminate these outliers respectively. Nine suspicious outliers were detected from calibration set which including 85 fruit samples. Considering the 9 suspicious outlier samples maybe contain some no-outlier samples, they were reclaimed to the model one by one to see whether they influence the model and prediction precision or not. In this way, 5 samples which were helpful to the model joined in calibration set again, and a new model was developed with the correlation coefficient (r) 0. 889 and root mean square errors for calibration (RMSEC) 0.6010 Brix. For 35 unknown samples, the root mean square errors prediction (RMSEP) was 0.854 degrees Brix. The performance of this model was more better than that developed with non outlier was eliminated from calibration set (r = 0.797, RMSEC= 0.849 degrees Brix, RMSEP = 1.19 degrees Brix), and more representative and stable with all 9 samples were eliminated from calibration set (r = 0.892, RMSEC = 0.605 degrees Brix, RMSEP = 0.862 degrees).
Santa, Cátia; Anjo, Sandra I; Manadas, Bruno
2016-07-01
Proteomic approaches are extremely valuable in many fields of research, where mass spectrometry methods have gained an increasing interest, especially because of the ability to perform quantitative analysis. Nonetheless, sample preparation prior to mass spectrometry analysis is of the utmost importance. In this work, two protein precipitation approaches, widely used for cleaning and concentrating protein samples, were tested and compared in very diluted samples solubilized in a strong buffer (containing SDS). The amount of protein recovered after acetone and TCA/acetone precipitation was assessed, as well as the protein identification and relative quantification by SWATH-MS yields were compared with the results from the same sample without precipitation. From this study, it was possible to conclude that in the case of diluted samples in denaturing buffers, the use of cold acetone as precipitation protocol is more favourable than the use of TCA/acetone in terms of reproducibility in protein recovery and number of identified and quantified proteins. Furthermore, the reproducibility in relative quantification of the proteins is even higher in samples precipitated with acetone compared with the original sample. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Mellert, Hestia S.; Alexander, Kristin E.; Jackson, Leisa P.; Pestano, Gary A.
2018-01-01
We have developed novel methods for the isolation and characterization of tumor-derived circulating ribonucleic acid (cRNA) for blood-based liquid biopsy. Robust detection of cRNA recovered from blood represents a solution to a critical unmet need in clinical diagnostics. The test begins with the collection of whole blood into blood collection tubes containing preservatives that stabilize cRNA. Cell-free, exosomal, and platelet-associated RNA is isolated from plasma in this test system. The cRNA is reverse transcribed to complementary DNA (cDNA) and amplified using digital polymerase chain reaction (dPCR). Samples are evaluated for both the target biomarker as well as a control gene. Test validation included limit of detection, accuracy, and robustness studies with analytic samples. The method developed as a result of these studies reproducibly detect multiple fusion variants for ROS1 (C-Ros proto-oncogene 1; 8 variants) and RET (rearranged during transfection proto-oncogene; 8 variants). The sample processing workflow has been optimized so that test results can consistently be generated within 72 hours of sample receipt. PMID:29683453
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wogman, Ned A.; Milbrath, Brian D.; Payne, Rosara F.
This paper is intended to serve as a scientific basis to start discussions of the available environmental sampling techniques and equipment that have been used in the past that could be considered for use within the context of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) on-site inspections (OSI). This work contains information on the techniques, equipment, costs, and some operational procedures associated with environmental sampling that have actually been used in the past by the United States for the detection of nuclear explosions. This paper also includes a discussion of issues, recommendations, and questions needing further study within the context of themore » sampling and analysis of aquatic materials, atmospheric gases, atmospheric particulates, vegetation, sediments and soils, fauna, and drill-back materials.« less
Gürgan, S; Onen, A; Köprülü, H
1997-03-01
Daily application of mouthrinses has been recommended for the prevention and control of caries and periodontal disease. The aim of this study was to evaluate the effect of alcohol-containing and alcohol-free mouthrinses on the microhardness of three restorative materials. Materials tested included visible light cured (VLC) composite resin (Amelogen), VLC glass-ionomer cement (Fuji II LC) and a fissure sealant (Ultra Seal XT). Eighteen cylinders of each restorative were fabricated and initially stored in distilled water for 24 h. Six samples of the restoratives were stored for 12 hours to simulate a 2 min/day for 1 year exposure to mouthrinses in the following solutions: distilled water (control), alcohol-containing mouthrinse (Viadent) and alcohol-free mouthrinse (Rembrandt). At the end of the test period microhardness was measured with a Tukon microhardness tester. Kruskal-Wallis one-way analysis of variance was used to analyse the data. Both mouthrinses affected the hardness of the materials tested.
Effects of the Maillard Reaction on the Immunoreactivity of Amandin in Food Matrices.
Chhabra, Guneet S; Liu, Changqi; Su, Mengna; Venkatachalam, Mahesh; Roux, Kenneth H; Sathe, Shridhar K
2017-10-01
Amandin is the major storage protein and allergen in almond seeds. Foods, containing almonds, subjected to thermal processing typically experience Maillard browning reaction. The resulting destruction of amino groups, protein glycation, and/or denaturation may alter amandin immunoreactivity. Amandin immunoreactivity of variously processed almond containing foods was therefore the focus of the current investigation. Commercial and laboratory prepared foods, including those likely to have been subjected to Maillard browning, were objectively assessed by determining Hunter L * , a * , b * values. The L * values for the tested samples were in the range of 31.75 to 85.28 consistent with Maillard browning. Three murine monoclonal antibodies, 4C10, 4F10, and 2A3, were used to determine the immunoreactivity of the targeted samples using immunoassays (ELISA, Western blot, dot blot). The tested foods did not exhibit cross-reactivity indicating that the immunoassays were amandin specific. For sandwich ELISAs, ratio (R) of sample immunoreactivity to reference immunoreactivity was calculated. The ranges of R values were 0.67 to 15.19 (4C10), 1.00 to 11.83 (4F10), and 0.77 to 23.30 (2A3). The results of dot blot and Western blot were consistent with those of ELISAs. Results of these investigations demonstrate that amandin is a stable marker protein for almond detection regardless of the degree of amandin denaturation and/or destruction as a consequence of Maillard reaction encountered under the tested processing conditions. Foods containing almond are often subjected to processing prior to consumption. Amandin, the major allergen in almond, may experience Maillard reaction. Understanding the change in amandin immunoreactivity as a result of Maillard reaction is important for amandin detection and production of hypoallergenic food products. © 2017 Institute of Food Technologists®.
Cnops, Lieselotte; Soentjens, Patrick; Clerinx, Jan; Van Esbroeck, Marjan
2013-01-01
Diagnosis of urogenital schistosomiasis by microscopy and serological tests may be elusive in travelers due to low egg load and the absence of seroconversion upon arrival. There is need for a more sensitive diagnostic test. Therefore, we developed a real-time PCR targeting the Schistosoma haematobium-specific Dra1 sequence. The PCR was evaluated on urine (n = 111), stool (n = 84) and serum samples (n = 135), and one biopsy from travelers and migrants with confirmed or suspected schistosomiasis. PCR revealed a positive result in 7/7 urine samples, 11/11 stool samples and 1/1 biopsy containing S. haematobium eggs as demonstrated by microscopy and in 22/23 serum samples from patients with a parasitological confirmed S. haematobium infection. S. haematobium DNA was additionally detected by PCR in 7 urine, 3 stool and 5 serum samples of patients suspected of having schistosomiasis without egg excretion in urine and feces. None of these suspected patients demonstrated other parasitic infections except one with Blastocystis hominis and Entamoeba cyst in a fecal sample. The PCR was negative in all stool samples containing S. mansoni eggs (n = 21) and in all serum samples of patients with a microscopically confirmed S. mansoni (n = 22), Ascaris lumbricoides (n = 1), Ancylostomidae (n = 1), Strongyloides stercoralis (n = 1) or Trichuris trichuria infection (n = 1). The PCR demonstrated a high specificity, reproducibility and analytical sensitivity (0.5 eggs per gram of feces). The real-time PCR targeting the Dra1 sequence for S. haematobium-specific detection in urine, feces, and particularly serum, is a promising tool to confirm the diagnosis, also during the acute phase of urogenital schistosomiasis.