Sample records for samples tested negative

  1. Evaluation of rapid diagnostic test kits for feline leukemia virus infection using samples from naturally infected cats.

    PubMed

    Liu, Jiayou; O'Connor, Thomas; Beall, Melissa; Chandrashekar, Ramaswamy; Lappin, Michael

    2016-01-01

    Feline leukemia virus (FeLV) is a potentially life-threatening oncogenic retrovirus. The p27 viral core protein is produced by the virus in infected feline cells, is found in the cytoplasm in several blood cells and can be free in the serum and plasma. ELISA or particle-based immunoassay are commonly used to detect the presence of the p27 core protein in samples obtained from blood. The objective of this study was to compare the performance of several in-clinic tests: the SNAP Feline Triple Test (IDEXX Laboratories), the WITNESS FeLV-FIV Test (Zoetis) and the VetScan Feline FeLV/FIV Rapid Test (Abaxis). The sample population (100 positive, 105 negative samples) consisted of serum and plasma samples submitted to IDEXX's worldwide reference laboratory for feline retrovirus testing. Virus isolation and reverse transcriptase PCR results were not available and so samples were judged to be positive or negative based on the results of the ViraCHEK FeLV (Zoetis) microtiter plate assay. The percentage of samples positive and negative for FeLV p27 antigen using the three in-clinic tests compared with the ViraCHEK method were as follows: IDEXX Feline Triple (positive 98.0%, negative 100%); Zoetis WITNESS (positive 79.0%, negative 97.1%); Abaxis VetScan (positive 73.0%, negative 97.1%). The SNAP Feline Triple Test demonstrated a high level of agreement for FeLV-positive and FeLV-negative samples when assessed in this model. Results of FeLV assays can vary among tests.

  2. Clinical comparison of the Treponema pallidum CAPTIA syphilis-G enzyme immunoassay with the fluorescent treponemal antibody absorption immunoglobulin G assay for syphilis testing.

    PubMed

    Halling, V W; Jones, M F; Bestrom, J E; Wold, A D; Rosenblatt, J E; Smith, T F; Cockerill, F R

    1999-10-01

    Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of >/=0.650 and 0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests which require subjective interpretation, like the FTA-ABS test, may be biased by RPR test results.

  3. Clinical Comparison of the Treponema pallidum CAPTIA Syphilis-G Enzyme Immunoassay with the Fluorescent Treponemal Antibody Absorption Immunoglobulin G Assay for Syphilis Testing

    PubMed Central

    Halling, V. W.; Jones, M. F.; Bestrom, J. E.; Wold, A. D.; Rosenblatt, J. E.; Smith, T. F.; Cockerill, F. R.

    1999-01-01

    Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of ≥0.650 and ≤0.900) were retested; if the second analysis produced an index of >0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests which require subjective interpretation, like the FTA-ABS test, may be biased by RPR test results. PMID:10488183

  4. Comparison of Clark's presence-absence test and the membrane filter method for coliform detection in potable water samples.

    PubMed Central

    Pipes, W O; Minnigh, H A; Moyer, B; Troy, M A

    1986-01-01

    A total of 2,601 water samples from six different water systems were tested for coliform bacteria by Clark's presence-absence (P-A) test and by the membrane filter (MF) method. There was no significant difference in the fraction of samples positive for coliform bacteria for any of the systems tested. It was concluded that the two tests are equivalent for monitoring purposes. However, 152 samples were positive for coliform bacteria by the MF method but negative by the P-A test, and 132 samples were positive by the P-A test but negative by the MF method. Many of these differences for individual samples can be explained by random dispersion of bacteria in subsamples when the coliform density is low. However, 15 samples had MF counts greater than 3 and gave negative P-A results. The only apparent explanation for most of these results is that coliform bacteria were present in the P-A test bottles but did not produce acid and gas. Two other studies have reported more samples positive by Clark's P-A test than by the MF method. PMID:3532953

  5. Evaluation of Line Immunoassay to Detect HTLV-1 Infection in an Endemic Area, Southwestern Japan; Comparison with Polymerase Chain Reaction and Western Blot.

    PubMed

    Umeki, Kazumi; Umekita, Kunihiko; Hashikura, Yuuki; Yamamoto, Ikuo; Kubo, Kazuyoshi; Nagatomo, Yasuhiro; Okayama, Akihiko

    2017-02-01

    Human T-lymphotropic virus type 1 (HTLV-1) has been recognized as a cause of adult T-cell leukemia/lymphoma, HTLV-1-associated myelopathy/tropical spastic paraparesis, and HTLV-1-associated uveitis. HTLV-1 infection is normally detected by screening for HTLV-1 antibodies, and positive samples are confirmed by Western blot (WB). However, WB fails to confirm some samples that were positive for HTLV-1 antibodies on screening. Line immunoassay (LIA) is commonly used in Europe and Brazil, but not in Japan. Therefore, we evaluated the performance of LIA as a method of confirming HTLV-1 antibodies using samples in Japan. LIA was compared with polymerase chain reaction (PCR) and WB using 50 negative and 70 positive samples tested by chemiluminescent enzyme immunoassay (CLEIA) in Miyazaki, Japan, an HTLV-1 endemic area. LIA (INNO-LIA HTLVI/II Score) and WB (Problot HTLV-I) were performed according to the manufacturer's instructions. Real-time PCR for HTLV-1 pX region was performed using DNA derived from white blood cells. The samples that tested negative by real-time PCR were further tested by nested PCR. All 50 CLEIA negative samples were determined to be negative by LIA and PCR. Of the 70 positive samples, 66 tested positive by both of LIA and PCR. Three samples tested negative by LIA and PCR, and the remaining sample (PCR negative) showed non-specific staining in LIA and WB. WB showed more indeterminate results than LIA. Gp21 antibody in LIA demonstrated a high ability to discriminate between positive and negative PCR results. Furthermore, the degree of gp21 antibody reaction by LIA showed correlation with HTLV-1 proviral loads (PVLs). Our results indicate that LIA performs well in confirming HTLV-1 seropositivity by showing a low incidence of indeterminate results and good agreement with PCR using samples in Japan, although the number of samples tested was small. In addition, semi-quantitative antibody titer to gp21 correlated well with HTLV-1 PVLs. Further study including larger samples is necessary to determine the positioning of LIA for HTLV-1 detection in Japan.

  6. Bayesian analysis of two diagnostic methods for paediatric ringworm infections in a teaching hospital.

    PubMed

    Rath, S; Panda, M; Sahu, M C; Padhy, R N

    2015-09-01

    Quantitatively, conventional methods of diagnosis of tinea capitis or paediatric ringworm, microscopic and culture tests were evaluated with Bayes rule. This analysis would help in quantifying the pervasive errors in each diagnostic method, particularly the microscopic method, as a long-term treatment would be involved to eradicate the infection by the use of a particular antifungal chemotherapy. Secondly, the analysis of clinical data would help in obtaining digitally the fallible standard of the microscopic test method, as the culture test method is taken as gold standard. Test results of 51 paediatric patients were of 4 categories: 21 samples were true positive (both tests positive), and 13 were true negative; the rest samples comprised both 14 false positive (microscopic test positivity with culture test negativity) and 3 false negative (microscopic test negativity with culture test positivity) samples. The prevalence of tinea infection was 47.01% in the population of 51 children. The microscopic test of a sample was efficient by 87.5%, in arriving at a positive result on diagnosis, when its culture test was positive; and, this test was efficient by 76.4%, in arriving at a negative result, when its culture test was negative. But, the post-test probability value of a sample with both microscopic and culture tests would be correct in distinguishing a sample from a sick or a healthy child with a chance of 71.5%. However, since the sensitivity of the analysis is 87.5%, the microscopic test positivity would be easier to detect in the presence of infection. In conclusion, it could be stated that Trychophyton rubrum was the most prevalent species; sensitivity and specificity of treating the infection, by antifungal therapy before ascertaining by the culture method remain as 0.8751 and 0.7642, respectively. A correct/coveted diagnostic method of fungal infection would be could be achieved by modern molecular methods (matrix-assisted laser desorption ionisation-time of flight mass spectrometry or fluorescence in situ hybridization or enzyme-linked immunosorbent assay [ELISA] or restriction fragment length polymorphism or DNA/RNA probes of known fungal taxa) in advanced laboratories. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  7. Retail Survey of Brazilian Milk and Minas Frescal Cheese and a Contaminated Dairy Plant To Establish Prevalence, Relatedness, and Sources of Listeria monocytogenes Isolates▿

    PubMed Central

    Brito, J. Renaldi F.; Santos, Emilia M. P.; Arcuri, Edna F.; Lange, Carla C.; Brito, Maria A. V. P.; Souza, Guilherme N.; Cerqueira, Mônica M. P. O.; Beltran, J. Marcela Soto; Call, Jeffrey E.; Liu, Yanhong; Porto-Fett, Anna C. S.; Luchansky, John B.

    2008-01-01

    A study was designed to recover Listeria monocytogenes from pasteurized milk and Minas frescal cheese (MFC) sampled at retail establishments (REs) and to identify the contamination source(s) of these products in the corresponding dairy processing plant. Fifty milk samples (9 brands) and 55 MFC samples (10 brands) were tested from REs located in Juiz de Fora, Minas Gerais, Brazil. All milk samples and 45 samples from 9 of 10 MFC brands tested negative for L. monocytogenes; however, “brand F” of MFC obtained from REs 119 and 159 tested positive. Thus, the farm/plant that produced brand F MFC was sampled; all samples from the milking parlor tested negative for L. monocytogenes, whereas several sites within the processing plant and the MFC samples tested positive. All 344 isolates recovered from retail MFC, plant F MFC, and plant F environmental samples were serotype 1/2a and displayed the same AscI or ApaI fingerprints. Since these results established that the storage coolers served as the contamination source of the MFC, plant F was closed so that corrective renovations could be made. Following renovation, samples from sites that previously tested positive for the pathogen were collected from the processing environment and from MFC on multiple visits; all tested negative for L. monocytogenes. In addition, on subsequent visits to REs 159 and 119, all MFC samples tested negative for the pathogen. Studies are ongoing to quantify the prevalence, levels, and types of L. monocytogenes in MFC and associated processing plants to lessen the likelihood of listeriosis in Brazil. PMID:18502929

  8. Quality Control of Direct Molecular Diagnostics for Methicillin-Resistant Staphylococcus aureus▿

    PubMed Central

    van Belkum, Alex; Niesters, Hubert G. M.; MacKay, William G.; van Leeuwen, Willem B.

    2007-01-01

    Ten samples containing various amounts of methicillin-resistant Staphylococcus aureus (MRSA), methicillin-susceptible S. aureus, methicillin-resistant Staphylococcus epidermidis (MRSE), and combinations thereof were distributed to 51 laboratories for molecular diagnostics testing. Samples containing 102 to 103 MRSA cells were frequently reported to be negative. MRSE samples were scored as negative by all commercial tests but by only two out of three in-house tests. PMID:17581936

  9. Discordant HIV Test Results: Implications on Perinatal and Haemotransfusion Screening for HIV Infection, Cape Coast, Ghana.

    PubMed

    Tetteh, Ato Kwamena; Agyarko, Edward

    2017-01-01

    Screening results of 488 pregnant women aged 15-44 years whose blood samples had been tested on-site, using First Response® HIV 1/2, and confirmed with INNO-LIA™ HIV I/II Score were used. Of this total, 178 were reactive (HIV I, 154; HIV II, 2; and HIV I and HIV II, 22). Of the 154 HIV I-reactive samples, 104 were confirmed to be HIV I-positive and 2 were confirmed to be HIV II-positive, while 48 were confirmed to be negative [false positive rate = 17.44% (13.56-21.32)]. The two HIV II samples submitted were confirmed to be negative with the confirmatory test. For the 22 HIV I and HIV II samples, 7 were confirmed to be HIV I-positive and 1 was confirmed to be HIV I- and HIV II-positive, while 14 were confirmed to be negative. Of the 310 nonreactive samples, 6 were confirmed to be HIV I-positive and 1 was confirmed to be HIV II-positive [false negative rate = 5.79% (1.63-8.38)], while 303 were negative. False negative outcomes will remain unconfirmed, with no management options for the client. False negative rate of 5.79% requires attention, as its resultant implications on control of HIV/AIDS could be dire.

  10. [Comparison of the CMV antigenemia test and CMV-DNA PCR results in solid organ transplant recipients].

    PubMed

    Özkarata, Emre; Özkarataş, Emre; Özbek, Ö Alpay; Avkan Oğuz, Vildan; Sayıner, A Arzu

    2016-01-01

    Cytomegalovirus (CMV) infection is among the most common important viral infections in solid organ transplant (SOT) recipients. Diagnostic tests for detecting CMV replication are widely used for this group of patients, however there is no clear agreement on the cut-off levels for interpretation of clinical decisions especially when the low level of viral load is detected. In this study, CMV pp65 antigenemia test results were compared with plasma CMV-DNA levels detected by quantitative real-time polymerase chain reaction (qPCR) in samples of kidney and liver transplant recipients in the Central Laboratory of Dokuz Eylul University Hospital between 2011 and 2013, and the correlation between these two tests and viral load equivalent to antigenemia positivity were determined. In the study, pp65 antigenemia and CMV-DNA qPCR results were evaluated retrospectively. The samples from the same patients were included if the time between antigenemia and CMV-DNA qPCR tests were less than 48 hours. SPSS v15.0 was used for correlation, regression and ROC curve analysis. The results of the 217 samples collected from 100 patients (59 male, 41 female; age range: 16-71, mean age: 46 ± 13 years), 36 liver and 64 kidney recipients were evaluated in the study. Of the patients 80% were CMV IgM negative, IgG positive; 1% was CMV IgG and IgM positive; 2% were CMV IgM and IgG negative, while for 17 patients serological results could not be reached. CMV pp65 antigenemia and CMV-DNA were both negative in 102 (47%) samples, while both were positive in 37 (17%) samples. The single sample from a case with CMV IgM and IgG positivity yielded negative results for both antigenemia and CMV-DNA tests. In 78 samples antigenemia were negative and CMV-DNA qPCR were positive, while there were no samples with antigenemia positive and qPCR negative. Mean values of antigenemia and qPCR tests were 23 positive cells/200.000 leukocytes (range: 1 to 230 positive cells) and 12.595 copies/ml (range: 180 to 106.311 copies/ml), respectively. There was a significant correlation between antigenemia and qPCR results among the samples that were positive by both assays (r= 0.785). ROC curve analysis showed that CMV viral load of 205 copies/ml in plasma corresponds to ≥ 1 pp65 antigen positive cells per 200.000 leukocytes (sensitivity: 91.7%, specificity: 90.3%). Higher analytical sensitivity of qPCR test can be explained by the results of CMV-DNA PCR positive and antigenemia negative samples. Non-existence of samples with antigen positive and PCR negative results supported this finding. ROC analysis showed that any sample with CMV-DNA qPCR result less than 205 copies/ml, could be accepted as pp65 antigenemia negative. This viral load value is valid only for the studied patient group and assays, therefore could be changed according to study population and tests.

  11. 7 CFR 58.243 - Checking quality.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    .... Periodically samples of product and environmental material shall be tested for salmonella. Test results shall be negative when samples are tested for salmonella. Line samples should be taken periodically as an...

  12. 7 CFR 58.243 - Checking quality.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    .... Periodically samples of product and environmental material shall be tested for salmonella. Test results shall be negative when samples are tested for salmonella. Line samples should be taken periodically as an...

  13. 7 CFR 58.243 - Checking quality.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    .... Periodically samples of product and environmental material shall be tested for salmonella. Test results shall be negative when samples are tested for salmonella. Line samples should be taken periodically as an...

  14. 7 CFR 58.243 - Checking quality.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    .... Periodically samples of product and environmental material shall be tested for salmonella. Test results shall be negative when samples are tested for salmonella. Line samples should be taken periodically as an...

  15. Quality of different in-clinic test systems for feline immunodeficiency virus and feline leukaemia virus infection.

    PubMed

    Hartmann, Katrin; Griessmayr, Pascale; Schulz, Bianka; Greene, Craig E; Vidyashankar, Anand N; Jarrett, Os; Egberink, Herman F

    2007-12-01

    Many new diagnostic in-house tests for identification of feline immunodeficiency virus (FIV) and feline leukaemia virus (FeLV) infection have been licensed for use in veterinary practice, and the question of the relative merits of these kits has prompted comparative studies. This study was designed to define the strengths and weaknesses of seven FIV and eight FeLV tests that are commercially available. In this study, 536 serum samples from randomly selected cats were tested. Those samples reacting FIV-positive in at least one of the tests were confirmed by Western blot, and those reacting FeLV-positive were confirmed by virus isolation. In addition, a random selection of samples testing negative in all test systems was re-tested by Western blot (100 samples) and by virus isolation (81 samples). Specificity, sensitivity, positive and negative predictive values of each test and the quality of the results were compared.

  16. Perfectionism, Performance, and State Positive Affect and Negative Affect after a Classroom Test

    ERIC Educational Resources Information Center

    Flett, Gordon L.; Blankstein, Kirk R.; Hewitt, Paul L.

    2009-01-01

    The current study examined the associations among trait dimensions of perfectionism, test performance, and levels of positive and negative affect after taking a test. A sample of 92 female university students completed the Multidimensional Perfectionism Scale one week prior to an actual class test. Measures of positive affect and negative affect…

  17. Discrepant HPV/cytology cotesting results: Are there differences between cytology-negative versus HPV-negative cervical intraepithelial neoplasia?

    PubMed

    Tracht, Jessica M; Davis, Antoinette D; Fasciano, Danielle N; Eltoum, Isam-Eldin A

    2017-10-01

    The objective of this study was to compare cervical high-grade squamous intraepithelial lesions subcategorized as cervical intraepithelial neoplasia-3 (CIN-3)-positive after a negative cytology result but positive for high-risk human papillomavirus (HR-HPV) testing to those with a negative HR-HPV test but positive cytology (atypical squamous cells of undetermined significance [ASCUS]-positive/HPV-negative) and to assess reasons for discrepancies. The authors retrospectively analyzed women who underwent screening with cytology and HPV testing from 2010 through 2013. After a review of surgical specimens and cytology, discrepancies were classified as sampling or interpretation error. Clinical and pathologic findings were compared. In total, 15,173 women (age range, 25-95 years; 7.1% were aged < 30 years) underwent both HPV and cytologic testing, and 1184 (8.4%) underwent biopsy. Cytology was positive in 19.4% of specimens, and HPV was positive in 14.5%. Eighty-four CIN-3-positive specimens were detected, including 55 that tested ASCUS-positive/HPV-positive, 11 that tested negative for intraepithelial lesion or malignancy (NILM)/HPV-positive, 10 that tested ASCUS-positive/HPV-negative, 3 that tested NILM/HPV-negative, and 5 tests that were unsatisfactory. There was no significant difference between NILM/HPV-positive and ASCUS-positive/HPV-negative CIN-3 in terms of size, time to occurrence, the presence of a cytopathic effect, screening history, race, or age. Six of 11 NILM/HPV-positive cases were reclassified as ASCUS, indicating an interpreting error of 55% and a sampling error of 45%. No ASCUS-positive/HPV-negative cases were reclassified. Seven cases of CIN-3 with positive cytology were HPV-negative. There are no significant clinical or pathologic differences between NILM/HPV-positive and ASCUS-positive/HPV-negative CIN-3-positive specimens. Cytologic sampling or interpretation remains the main reason for discrepancies. However, HPV-negative CIN-3 with positive cytology exists and may be missed by primary HPV screening. Cancer Cytopathol 2017;125:795-805. © 2017 American Cancer Society. © 2017 American Cancer Society.

  18. Microbial ecology measurement system

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The sensitivity and potential rapidity of the PIA test that was demonstrated during the feasibility study warranted continuing the effort to examine the possibility of adapting this test to an automated procedure that could be used during manned missions. The effort during this program has optimized the test conditions for two important respiratory pathogens, influenza virus and Mycoplasma pneumoniae, developed a laboratory model automated detection system, and investigated a group antigen concept for virus detection. Preliminary tests on the handling of oropharygeal clinical samples for PIA testing were performed using the adenovirus system. The results obtained indicated that the PIA signal is reduced in positive samples and is increased in negative samples. Treatment with cysteine appeared to reduce nonspecific agglutination in negative samples but did not maintain the signal in positive samples.

  19. Serological diagnosis of bovine brucellosis using B. melitensis strain B115.

    PubMed

    Corrente, Marialaura; Desario, Costantina; Parisi, Antonio; Grandolfo, Erika; Scaltrito, Domenico; Vesco, Gesualdo; Colao, Valeriana; Buonavoglia, Domenico

    2015-12-01

    Bovine brucellosis is diagnosed by official tests, such as Rose Bengal plate test (RBPT) and Complement Fixation test (CFT). Both tests detect antibodies directed against the lipolysaccharide (LPS) of Brucella cell wall. Despite their good sensitivity, those tests do not discriminate between true positive and false positive serological reactions (FPSR), the latter being generated by animals infected with other Gram negative microorganisms that share components of Brucella LPS. In this study, an antigenic extract from whole Brucella melitensis B115 strain was used to set up an ELISA assay for the serological diagnosis of bovine brucellosis. A total of 148 serum samples from five different groups of animals were tested: Group A: 28 samples from two calves experimentally infected with Yersinia enterocolitica O:9; Group B: 30 samples from bovines infected with Brucella abortus; Group C: 50 samples from brucellosis-free herds; Group D: 20 samples RBPT positive and CFT negative; Group E: 20 samples both RBPT and CFT positive. Group D and Group E serum samples were from brucellosis-free herds. Positive reactions were detected only by RBPT and CFT in calves immunized with Y. enterocolitica O:9. Sera from Group B animals tested positive also in the ELISA assay, whereas sera from the remaining groups were all negative. The results obtained encourage the use of the ELISA assay to implement the serological diagnosis of brucellosis. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Performance of the fourth-generation Bio-Rad GS HIV Combo Ag/Ab enzyme immunoassay for diagnosis of HIV infection in Southern Africa

    PubMed Central

    Piwowar-Manning, Estelle; Fogel, Jessica M.; Richardson, Paul; Wolf, Shauna; Clarke, William; Marzinke, Mark A.; Fiamma, Agnès; Donnell, Deborah; Kulich, Michal; Mbwambo, Jessie K.K.; Richter, Linda; Gray, Glenda; Sweat, Michael; Coates, Thomas J.; Eshleman, Susan H.

    2015-01-01

    Background Fourth-generation HIV assays detect both antigen and antibody, facilitating detection of acute/early HIV infection. The Bio-Rad GS HIV Combo Ag/Ab assay (Bio-Rad Combo) is an enzyme immunoassay that simultaneously detects HIV p24 antigen and antibodies to HIV-1 and HIV-2 in serum or plasma. Objective To evaluate the performance of the Bio-Rad Combo assay for detection of HIV infection in adults from Southern Africa. Study design Samples were obtained from adults in Soweto and Vulindlela, South Africa and Dar es Salaam, Tanzania (300 HIV-positive samples; 300 HIV-negative samples; 12 samples from individuals previously classified as having acute/early HIV infection). The samples were tested with the Bio-Rad Combo assay. Additional testing was performed to characterize the 12 acute/early samples. Results All 300 HIV-positive samples were reactive using the Bio-Rad Combo assay; false positive test results were obtained for 10 (3.3%) of the HIV-negative samples (sensitivity: 100%, 95% confidence interval [CI]: 98.8–100%); specificity: 96.7%, 95% CI: 94.0–98.4%). The assay detected 10 of the 12 infections classified as acute/early. The two infections that were not detected had viral loads < 400 copies/mL; one of those samples contained antiretroviral drugs consistent with antiretroviral therapy. Conclusions The Bio-Rad Combo assay correctly classified the majority of study specimens. The specificity reported here may be higher than that seen in other settings, since HIV-negative samples were pre-screened using a different fourth-generation test. The assay also had high sensitivity for detection of acute/early infection. False-negative test results may be obtained in individuals who are virally suppressed. PMID:25542477

  1. Performance of the BioPlex 2200 HIV Ag-Ab assay for identifying acute HIV infection.

    PubMed

    Eshleman, Susan H; Piwowar-Manning, Estelle; Sivay, Mariya V; Debevec, Barbara; Veater, Stephanie; McKinstry, Laura; Bekker, Linda-Gail; Mannheimer, Sharon; Grant, Robert M; Chesney, Margaret A; Coates, Thomas J; Koblin, Beryl A; Fogel, Jessica M

    Assays that detect HIV antigen (Ag) and antibody (Ab) can be used to screen for HIV infection. To compare the performance of the BioPlex 2200 HIV Ag-Ab assay and two other Ag/Ab combination assays for detection of acute HIV infection. Samples were obtained from 24 individuals (18 from the US, 6 from South Africa); these individuals were classified as having acute infection based on the following criteria: positive qualitative RNA assay; two negative rapid tests; negative discriminatory test. The samples were tested with the BioPlex assay, the ARCHITECT HIV Ag/Ab Combo test, the Bio-Rad GS HIV Combo Ag-Ab EIA test, and a viral load assay. Twelve (50.0%) of 24 samples had RNA detected only ( > 40 to 13,476 copies/mL). Ten (43.5%) samples had reactive results with all three Ag/Ab assays, one sample was reactive with the ARCHITECT and Bio-Rad assays, and one sample was reactive with the Bio-Rad and BioPlex assays. The 11 samples that were reactive with the BioPlex assay had viral loads from 83,010 to >750,000 copies/mL; 9/11 samples were classified as Ag positive/Ab negative by the BioPlex assay. Detection of acute HIV infection was similar for the BioPlex assay and two other Ag/Ab assays. All three tests were less sensitive than a qualitative RNA assay and only detected HIV Ag when the viral load was high. The BioPlex assay detected acute infection in about half of the cases, and identified most of those infections as Ag positive/Ab negative. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Exploring the cause of initially reactive bovine brains on rapid tests for BSE

    PubMed Central

    Dudas, Sandor; James, Jace; Anderson, Renee; Czub, Stefanie

    2015-01-01

    ABSTRACT Bovine spongiform encephalopathy (BSE) is an invariably fatal prion disease of cattle. The identification of the zoonotic potential of BSE prompted safety officials to initiate surveillance testing for this disease. In Canada, BSE surveillance is primarily focused on high risk cattle including animals which are dead, down and unable to rise, diseased or distressed. This targeted surveillance results in the submission of brain samples with a wide range of tissue autolysis and associated contaminants. These contaminants have the potential to interfere with important steps of surveillance tests resulting in initially positive test results requiring additional testing to confirm the disease status of the animal. The current tests used for BSE screening in Canada utilize the relative protease resistance of the prion protein gained when it misfolds from PrPC to PrPSc as part of the disease process. Proteinase K completely digests PrPC in normal brains, but leaves most of the PrPSc in BSE positive brains intact which is detected using anti-prion antibodies. These tests are highly reliable but occasionally give rise to initially reactive/false positive results. Test results for these reactive samples were close to the positive/negative cut-off on a sub set of test platforms. This is in contrast to all of the previous Canadian positive samples whose numeric values on these same test platforms were 10 to 100 fold greater than the test positive/negative cut-off. Here we explore the potential reason why a sample is repeatedly positive on a sub-set of rapid surveillance tests, but negative on other test platforms. In order to better understand and identify what might cause these initial reactions, we have conducted a variety of rapid and confirmatory assays as well as bacterial isolation and identification on BSE positive, negative and initially reactive samples. We observed high levels of viable bacterial contamination in initially reactive samples suggesting that the reactivity may be related to bacterial factors. Several bacteria isolated from the initially reactive samples have characteristics of biofilm forming bacteria and this extracellular matrix might play a role in preventing complete digestion of PrPC in these samples. PMID:26689488

  3. A Rapid Dot Immunoassay for the Detection of Serum Antibodies to Eastern Equine Encephalomyelitis and Saint Louis Encephalitis Viruses in Sentinel Chickens

    DTIC Science & Technology

    1988-01-01

    tion inhibition (HI) tests .6 uses a novel membrane, polyvinylydine difluor- EEE and SLE viruses are significant public ide (PVDF), and yields a...only 3 aged values between the two tests (Fig. 3). Vari- of 6 SLE virus-inoculated birds developed an- ability in EIA titer was observed with samples... SLE samples negative by EIA were location. Four serum samples from each of 3 also negative by DotIA. EEE-positive chickens were tested by EIA and A

  4. Screening for tinea unguium by Dermatophyte Test Strip.

    PubMed

    Tsunemi, Y; Takehara, K; Miura, Y; Nakagami, G; Sanada, H; Kawashima, M

    2014-02-01

    The direct microscopy, fungal culture and histopathology that are necessary for the definitive diagnosis of tinea unguium are disadvantageous in that detection sensitivity is affected by the level of skill of the person who performs the testing, and the procedures take a long time. The Dermatophyte Test Strip, which was developed recently, can simply and easily detect filamentous fungi in samples in a short time, and there are expectations for its use as a method for tinea unguium screening. With this in mind, we examined the detection capacity of the Dermatophyte Test Strip for tinea unguium. The presence or absence of fungal elements was judged by direct microscopy and Dermatophyte Test Strip in 165 nail samples obtained from residents in nursing homes for the elderly. Moreover, the minimum sample amount required for positive determination was estimated using 32 samples that showed positive results by Dermatophyte Test Strip. The Dermatophyte Test Strip showed 98% sensitivity, 78% specificity, 84·8% positive predictive value, 97% negative predictive value and a positive and negative concordance rate of 89·1%. The minimum sample amount required for positive determination was 0·002-0·722 mg. The Dermatophyte Test Strip showed very high sensitivity and negative predictive value, and was considered a potentially useful method for tinea unguium screening. Positive determination was considered to be possible with a sample amount of about 1 mg. © 2013 British Association of Dermatologists.

  5. Broadband Respiratory Virus Surveillance

    DTIC Science & Technology

    2011-10-01

    Simplex Virus (HSV) and 19 Enterovirus 7 positive as well as 11 HSV negative specimens as determined by the TAMC Department of Pathology’s current gold...negative, and 19 Enterovirus positive samples were to serve as negative controls as the RVS plate did not have primers to assay for HSV or Enterovirus . As...expected, all of these specimens ( Enterovirus , HSV positive and negative virus samples) tested negative on the RVS plate. This demonstrated 100

  6. Development and Evaluation of a Rapid and Sensitive EBOV-RPA Test for Rapid Diagnosis of Ebola Virus Disease.

    PubMed

    Yang, Mingjuan; Ke, Yuehua; Wang, Xuesong; Ren, Hang; Liu, Wei; Lu, Huijun; Zhang, Wenyi; Liu, Shiwei; Chang, Guohui; Tian, Shuguang; Wang, Lihua; Huang, Liuyu; Liu, Chao; Yang, Ruifu; Chen, Zeliang

    2016-06-01

    Confirming Ebola virus disease (EVD), a deadly infectious disease, requires real-time RT-PCR, which takes up to a few hours to yield results. Therefore, a rapid diagnostic assay is imperative for EVD diagnosis. A rapid nucleic acid test based on recombinase polymerase amplification (EBOV-RPA) was developed to specifically detect the 2014 outbreak strains. The EBOV-RPA assay was evaluated by testing samples from suspected EVD patients in parallel with RT-PCR. An EBOV-RPA, which could be completed in 20 min, was successfully developed. Of 271 patients who tested positive for Ebola virus by RT-PCR, 264 (sensitivity: 97%, 95% CI: 95.5-99.3%) were positive by EBOV-RPA; 101 of 104 patients (specificity: 97%, 95% CI: 93.9-100%) who tested negative by RT-PCR were also negative by EBOV-RPA. The sensitivity values for samples with a Ct value of <34, which accounted for 95.59% of the samples, was 100%. Discordant samples positive by RT-PCR but negative by EBOV-RPA had significantly high Ct values. Results of external quality assessment samples with EBOV-RPA were 100%, consistent with those of RT-PCR. The EBOV-RPA assay showed 97% sensitivity and 97% specificity for all EVD samples tested, making it a rapid and sensitive test for EVD diagnosis.

  7. Contamination with HIV antibody may be responsible for false positive results in specimens tested on automated platforms running HIV 4th generation assays in a region of high HIV prevalence.

    PubMed

    Hardie, Diana Ruth; Korsman, Stephen N; Hsiao, Nei-Yuan; Morobadi, Molefi Daniel; Vawda, Sabeehah; Goedhals, Dominique

    2017-01-01

    In South Africa where the prevalence of HIV infection is very high, 4th generation HIV antibody/p24 antigen combo immunoassays are the tests of choice for laboratory based screening. Testing is usually performed in clinical pathology laboratories on automated analysers. To investigate the cause of false positive results on 4th generation HIV testing platforms in public sector laboratories, the performance of two automated platforms was compared in a clinical pathology setting, firstly on routine diagnostic specimens and secondly on known sero-negative samples. Firstly, 1181 routine diagnostic specimens were sequentially tested on Siemens and Roche automated 4th generation platforms. HIV viral load, western blot and follow up testing were used to determine the true status of inconclusive specimens. Subsequently, known HIV seronegative samples from a single donor were repeatedly tested on both platforms and an analyser was tested for surface contamination with HIV positive serum to identify how suspected specimen contamination could be occurring. Serial testing of diagnostic specimens yielded 163 weakly positive or discordant results. Only 3 of 163 were conclusively shown to indicate true HIV infection. Specimen contamination with HIV antibody was suspected, based on the following evidence: the proportion of positive specimens increased on repeated passage through the analysers; viral loads were low or undetectable and western blots negative or indeterminate on problem specimens; screen negative, 2nd test positive specimens tested positive when reanalysed on the screening assay; follow up specimens (where available) were negative. Similarly, an increasing number of known negative specimens became (repeatedly) sero-positive on serial passage through one of the analysers. Internal and external analyser surfaces were contaminated with HIV serum, evidence that sample splashes occur during testing. Due to the extreme sensitivity of these assays, contamination with minute amounts of HIV antibody can cause a negative sample to test positive. Better contamination control measures are needed on analysers used in clinical pathology environments, especially in regions where HIV sero-prevalence is high.

  8. Bovine virus diarrhea virus in free-living deer from Denmark.

    PubMed

    Nielsen, S S; Roensholt, L; Bitsch, V

    2000-07-01

    Free-living deer are suggested as a possible source of infection of cattle with bovine virus diarrhea (BVD) virus. To examine this hypothesis blood samples from 476 free-living deer were collected during two different periods and tested for BVD virus and antibody in Denmark. In 1995-96, 207 animals were tested. These included 149 roe deer (Capreolus capreolus), 29 fallow deer (Dama dama), 20 red deer (Cervus elaphus) and one sika deer (Cervus sika). For the remaining eight animals no species information was available. In 1998-99, 269 animals were tested including 212 roe deer and 57 red deer. The animals were selected from areas with a relatively high prevalence of cattle herds with a BVD persistent infection status in 1997 and 1998. All 207 samples from 1995-96 were found antibody-negative except two samples from red deer. Only 158 of the 207 samples were tested for virus and were all found negative. Of the 269 samples from 1998-99 all but one were antibody negative. The positive sample was from a red deer. All samples were virus-negative. It appears that BVD infection does not occur in roe deer in Denmark. The presence of antibody in a few red deer from various districts in Jutland probably results from cattle to deer transmission, rather than spread among deer. Hence, the possibility of free-living deer as a source of infection for cattle in Denmark seems to be remote.

  9. Performance of the TB-LAMP diagnostic assay in reference laboratories: Results from a multicentre study.

    PubMed

    Pham, Thu Hang; Peter, Jonathan; Mello, Fernanda C Q; Parraga, Tommy; Lan, Nguyen Thi Ngoc; Nabeta, Pamela; Valli, Eloise; Caceres, Tatiana; Dheda, Keertan; Dorman, Susan E; Hillemann, Doris; Gray, Christen M; Perkins, Mark D

    2018-03-01

    To evaluate the diagnostic performance of TB-LAMP, a manual molecular tuberculosis (TB) detection method, and provide comparison to the Xpert MTB/RIF assay. In a large multicentre study, two sputum samples were collected from participants with TB symptoms in reference laboratories in Peru, South Africa, Brazil, and Vietnam. Each sample was tested with TB-LAMP. The reference standard consisted of four direct smears, four cultures, and clinical and radiological findings. Individuals negative on conventional tests were followed up after 8 weeks. The Xpert MTB/RIF assay was performed on fresh or frozen samples as a molecular test comparison. A total of 1036 adults with suspected TB were enrolled. Among 375 culture-confirmed TB cases with 750 sputum samples, TB-LAMP detected 75.6% (95% confidence interval (CI) 71.8-79.4%), including 97.9% (95% CI 96.4-99.4%) of smear-positive TB samples and 46.6% (95% CI 40.6-52.7%) of smear-negative TB samples. Specificity in 477 culture-negative participants not treated for TB (954 sputum samples) was 98.7% (95% CI 97.9-99.6%). TB-LAMP test results were indeterminate in 0.3% of cases. TB-LAMP detects nearly all smear-positive and half of smear-negative TB cases and has a high specificity when performed in reference laboratories. Performance was similar to the Xpert MTB/RIF assay. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  10. Automation of serum (1→3)-beta-D-glucan testing allows reliable and rapid discrimination of patients with and without candidemia.

    PubMed

    Prüller, Florian; Wagner, Jasmin; Raggam, Reinhard B; Hoenigl, Martin; Kessler, Harald H; Truschnig-Wilders, Martie; Krause, Robert

    2014-07-01

    Testing for (1→3)-beta-D-glucan (BDG) is used for detection of invasive fungal infection. However, current assays lack automation and the ability to conduct rapid single-sample testing. The Fungitell assay was adopted for automation and evaluated using clinical samples from patients with culture-proven candidemia and from culture-negative controls in duplicate. A comparison with the standard assay protocol was made in order to establish analytical specifications. With the automated protocol, the analytical measuring range was 8-2500 pg/ml of BDG, and precision testing resulted in coefficients of variation that ranged from 3.0% to 5.5%. Samples from 15 patients with culture-proven candidemia and 94 culture-negative samples were evaluated. All culture-proven samples showed BDG values >80 pg/ml (mean 1247 pg/ml; range, 116-2990 pg/ml), which were considered positive. Of the 94 culture-negative samples, 92 had BDG values <60 pg/ml (mean, 28 pg/ml), which were considered to be negative, and 2 samples were false-positive (≥80 pg/ml; up to 124 pg/ml). Results could be obtained within 45 min and showed excellent agreement with results obtained with the standard assay protocol. The automated Fungitell assay proved to be reliable and rapid for diagnosis of candidemia. It was demonstrated to be feasible and cost efficient for both single-sample and large-scale testing of serum BDG. Its 1-h time-to-result will allow better support for clinicians in the management of antifungal therapy. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. Experimental layout, data analysis, and thresholds in ELISA testing of maize for aphid-borne viruses.

    PubMed

    Caciagli, P; Verderio, A

    2003-06-30

    Several aspects of enzyme-linked immunosorbent assay (ELISA) procedures and data analysis have been examined in an attempt to find a rapid and reliable method for discriminating between 'positive' and 'negative' results when testing a large number of samples. A layout of ELISA plates was designed to reduce uncontrolled variation and to optimize the number of negative and positive controls. A transformation using the fourth root (A(1/4)) of the optical density readings corrected for the blank (A) stabilized the variance of most ELISA data examined. Transformed A values were used to calculate the true limits, at a set protection level, for false positive (C) and false negative (D). Methods are discussed to reduce the number of undifferentiated samples, i.e. the samples with response falling between C and D. The whole procedure was set up for use with an electronic spreadsheet. With the addition of few instructions of the type 'if em leader then em leader else' in the spreadsheet, the ELISA results were obtained in the simple trichotomous form 'negative/undefined/positive'. This allowed rapid analysis of more than 1100 maize samples testing for the presence of seven aphid-borne viruses-in fact almost 8000 ELISA samples.

  12. Occupancy Modeling for Improved Accuracy and Understanding of Pathogen Prevalence and Dynamics

    PubMed Central

    Colvin, Michael E.; Peterson, James T.; Kent, Michael L.; Schreck, Carl B.

    2015-01-01

    Most pathogen detection tests are imperfect, with a sensitivity < 100%, thereby resulting in the potential for a false negative, where a pathogen is present but not detected. False negatives in a sample inflate the number of non-detections, negatively biasing estimates of pathogen prevalence. Histological examination of tissues as a diagnostic test can be advantageous as multiple pathogens can be examined and providing important information on associated pathological changes to the host. However, it is usually less sensitive than molecular or microbiological tests for specific pathogens. Our study objectives were to 1) develop a hierarchical occupancy model to examine pathogen prevalence in spring Chinook salmon Oncorhynchus tshawytscha and their distribution among host tissues 2) use the model to estimate pathogen-specific test sensitivities and infection rates, and 3) illustrate the effect of using replicate within host sampling on sample sizes required to detect a pathogen. We examined histological sections of replicate tissue samples from spring Chinook salmon O. tshawytscha collected after spawning for common pathogens seen in this population: Apophallus/echinostome metacercariae, Parvicapsula minibicornis, Nanophyetus salmincola/ metacercariae, and Renibacterium salmoninarum. A hierarchical occupancy model was developed to estimate pathogen and tissue-specific test sensitivities and unbiased estimation of host- and organ-level infection rates. Model estimated sensitivities and host- and organ-level infections rates varied among pathogens and model estimated infection rate was higher than prevalence unadjusted for test sensitivity, confirming that prevalence unadjusted for test sensitivity was negatively biased. The modeling approach provided an analytical approach for using hierarchically structured pathogen detection data from lower sensitivity diagnostic tests, such as histology, to obtain unbiased pathogen prevalence estimates with associated uncertainties. Accounting for test sensitivity using within host replicate samples also required fewer individual fish to be sampled. This approach is useful for evaluating pathogen or microbe community dynamics when test sensitivity is <100%. PMID:25738709

  13. Occupancy modeling for improved accuracy and understanding of pathogen prevalence and dynamics

    USGS Publications Warehouse

    Colvin, Michael E.; Peterson, James T.; Kent, Michael L.; Schreck, Carl B.

    2015-01-01

    Most pathogen detection tests are imperfect, with a sensitivity < 100%, thereby resulting in the potential for a false negative, where a pathogen is present but not detected. False negatives in a sample inflate the number of non-detections, negatively biasing estimates of pathogen prevalence. Histological examination of tissues as a diagnostic test can be advantageous as multiple pathogens can be examined and providing important information on associated pathological changes to the host. However, it is usually less sensitive than molecular or microbiological tests for specific pathogens. Our study objectives were to 1) develop a hierarchical occupancy model to examine pathogen prevalence in spring Chinook salmonOncorhynchus tshawytscha and their distribution among host tissues 2) use the model to estimate pathogen-specific test sensitivities and infection rates, and 3) illustrate the effect of using replicate within host sampling on sample sizes required to detect a pathogen. We examined histological sections of replicate tissue samples from spring Chinook salmon O. tshawytscha collected after spawning for common pathogens seen in this population:Apophallus/echinostome metacercariae, Parvicapsula minibicornis, Nanophyetus salmincola/metacercariae, and Renibacterium salmoninarum. A hierarchical occupancy model was developed to estimate pathogen and tissue-specific test sensitivities and unbiased estimation of host- and organ-level infection rates. Model estimated sensitivities and host- and organ-level infections rates varied among pathogens and model estimated infection rate was higher than prevalence unadjusted for test sensitivity, confirming that prevalence unadjusted for test sensitivity was negatively biased. The modeling approach provided an analytical approach for using hierarchically structured pathogen detection data from lower sensitivity diagnostic tests, such as histology, to obtain unbiased pathogen prevalence estimates with associated uncertainties. Accounting for test sensitivity using within host replicate samples also required fewer individual fish to be sampled. This approach is useful for evaluating pathogen or microbe community dynamics when test sensitivity is <100%.

  14. Geologic and hydraulic characteristics of selected shaly geologic units in Oklahoma

    USGS Publications Warehouse

    Becker, C.J.; Overton, M.D.; Johnson, K.S.; Luza, K.V.

    1997-01-01

    Information was collected on the geologic and hydraulic characteristics of three shale-dominated units in Oklahoma-the Dog Creek Shale and Chickasha Formation in Canadian County, Hennessey Group in Oklahoma County, and the Boggy Formation in Pittsburg County. The purpose of this project was to gain insight into the characteristics controlling fluid flow in shaly units that could be targeted for confinement of hazardous waste in the State and to evaluate methods of measuring hydraulic characteristics of shales. Permeameter results may not indicate in-place small-scale hydraulic characteristics, due to pretest disturbance and deterioration of core samples. The Dog Creek Shale and Chickasha Formation hydraulic conductivities measured by permeameter methods ranged from 2.8 times 10 to the negative 11 to 3.0 times 10 to the negative 7 meter per second in nine samples and specific storage from 3.3 times 10 to the negative 4 to 1.6 times 10 to the negative 3 per meter in four samples. Hennessey Group hydraulic conductivities ranged from 4.0 times 10 to the negative 12 to 4.0 times 10 to the negative 10 meter per second in eight samples. Hydraulic conductivity in the Boggy Formation ranged from 1.7 times 10 to the negative 12 to 1.0 times 10 to the negative 8 meter per second in 17 samples. The hydraulic properties of isolated borehole intervals of average length of 4.5 meters in the Hennessey Group and the Boggy Formation were evaluated by a pressurized slug-test method. Hydraulic conductivities obtained with this method tend to be low because intervals with features that transmitted large volumes of water were not tested. Hennessey Group hydraulic conductivities measured by this method ranged from 3.0 times 10 to the negative 13 to 1.1 times 10 to the negative 9 meter per second; the specific storage values are small and may be unreliable. Boggy Formation hydraulic conductivities ranged from 2.0 times 10 to the negative 13 to 2.7 times 10 to the negative 10 meter per second and specific storage values in these tests also are small and may be unreliable. A substantially higher hydraulic conductivity of 3.0 times 10 to the negative 8 meter per second was measured in one borehole 30 meters deep in the Boggy Formation using an open hole slug-test method.

  15. Hog Charm II tetracycline test screening results compared with a liquid chromatography tandem mass spectrometry 10-μg/kg method.

    PubMed

    Salter, Robert; Holmes, Steven; Legg, David; Coble, Joel; George, Bruce

    2012-02-01

    Pork tissue samples that tested positive and negative by the Charm II tetracycline test screening method in the slaughter plant laboratory were tested with the modified AOAC International liquid chromatography tandem mass spectrometry (LC-MS-MS) method 995.09 to determine the predictive value of the screening method at detecting total tetracyclines at 10 μg/kg of tissue, in compliance with Russian import regulations. There were 218 presumptive-positive tetracycline samples of 4,195 randomly tested hogs. Of these screening test positive samples, 83% (182) were positive, >10 μg/kg by LC-MS-MS; 12.8% (28) were false violative, greater than limit of detection (LOD) but <10 μg/kg; and 4.2% (8) were not detected at the LC-MS-MS LOD. The 36 false-violative and not-detected samples represent 1% of the total samples screened. Twenty-seven of 30 randomly selected tetracycline screening negative samples tested below the LC-MS-MS LOD, and 3 samples tested <3 μg/kg chlortetracycline. Results indicate that the Charm II tetracycline test is effective at predicting hogs containing >10 μg/kg total tetracyclines in compliance with Russian import regulations.

  16. Evaluation of OMNIgene®•SPUTUM-stabilised sputum for long-term transport and Xpert® MTB/RIF testing in Nepal.

    PubMed

    Maharjan, B; Kelly-Cirino, C D; Weirich, A; Curry, P S; Hoffman, H; Avsar, K; Shrestha, B

    2016-12-01

    German Nepal TB Project, National Tuberculosis Reference Laboratory, Kathmandu, Nepal. To evaluate whether transporting samples in OMNIgene®•SPUTUM (OM-S) reagent from a peripheral collection site to a central laboratory in Nepal can improve tuberculosis (TB) detection and increase the sensitivity of Xpert® MTB/RIF testing. One hundred sputum samples were split manually. Each portion was assigned to the OM-S group (OM-S added at collection, airline-couriered without cold chain, no other processing required) or the standard-of-care (SOC) group (samples airline-couriered on ice, sodium hydroxide + N-acetyl-L-cysteine processing required at the laboratory). Smear microscopy and Xpert testing were performed. Transport time was 2-13 days. Overall smear results were comparable (respectively 58% and 56% smear-negative results in the OM-S and SOC groups). The rate of smear-positive, Mycobacterium tuberculosis-positive (MTB+) sample detection was identical for both treatment groups, at 95%. More smear-negative MTB+ samples were detected in the OM-S group (17% vs. 13%, P = 0.0655). Sputum samples treated with OM-S can undergo multiday ambient-temperature transport and yield comparable smear and Xpert results to those of SOC samples. Further investigation with larger sample sizes is required to assess whether treating sputum samples with OM-S could increase the sensitivity of Xpert testing in smear-negative samples.

  17. Classification of bacterial samples as negative or positive for a UTI and antibiogram using surface enhanced Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Kastanos, Evdokia; Hadjigeorgiou, Katerina; Kyriakides, Alexandros; Pitris, Costas

    2011-03-01

    Urinary tract infection (UTI) diagnosis requires an overnight culture to identify a sample as positive or negative for a UTI. Additional cultures are required to identify the pathogen responsible for the infection and to test its sensitivity to antibiotics. A rise in ineffective treatments, chronic infections, rising health care costs and antibiotic resistance are some of the consequences of this prolonged waiting period of UTI diagnosis. In this work, Surface Enhanced Raman Spectroscopy (SERS) is used for classifying bacterial samples as positive or negative for UTI. SERS spectra of serial dilutions of E.coli bacteria, isolated from a urine culture, were classified as positive (105-108 cells/ml) or negative (103-104 cells/ml) for UTI after mixing samples with gold nanoparticles. A leave-one-out cross validation was performed using the first two principal components resulting in the correct classification of 82% of all samples. Sensitivity of classification was 88% and specificity was 67%. Antibiotic sensitivity testing was also done using SERS spectra of various species of gram negative bacteria collected 4 hours after exposure to antibiotics. Spectral analysis revealed clear separation between the spectra of samples exposed to ciprofloxacin (sensitive) and amoxicillin (resistant). This study can become the basis for identifying urine samples as positive or negative for a UTI and determining their antibiogram without requiring an overnight culture.

  18. DEMINERALIZER BUILDING, TRA608. INSTALLATION OF SAMPLING AND OTHER INSTRUMENTS COMPLETES ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DEMINERALIZER BUILDING, TRA-608. INSTALLATION OF SAMPLING AND OTHER INSTRUMENTS COMPLETES DEMINERALIZER UNITS ALONG NORTH WALL. CAMERA FACES EAST. CARD IN LOWER RIGHT WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION PRINTED ON THE ORIGINAL NEGATIVE. INL NEGATIVE NO. 3996A. Unknown Photographer, 12/28/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  19. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    PubMed

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  20. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    PubMed Central

    2012-01-01

    Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals. PMID:22429706

  1. The test-negative design for estimating influenza vaccine effectiveness.

    PubMed

    Jackson, Michael L; Nelson, Jennifer C

    2013-04-19

    The test-negative design has emerged in recent years as the preferred method for estimating influenza vaccine effectiveness (VE) in observational studies. However, the methodologic basis of this design has not been formally developed. In this paper we develop the rationale and underlying assumptions of the test-negative study. Under the test-negative design for influenza VE, study subjects are all persons who seek care for an acute respiratory illness (ARI). All subjects are tested for influenza infection. Influenza VE is estimated from the ratio of the odds of vaccination among subjects testing positive for influenza to the odds of vaccination among subjects testing negative. With the assumptions that (a) the distribution of non-influenza causes of ARI does not vary by influenza vaccination status, and (b) VE does not vary by health care-seeking behavior, the VE estimate from the sample can generalized to the full source population that gave rise to the study sample. Based on our derivation of this design, we show that test-negative studies of influenza VE can produce biased VE estimates if they include persons seeking care for ARI when influenza is not circulating or do not adjust for calendar time. The test-negative design is less susceptible to bias due to misclassification of infection and to confounding by health care-seeking behavior, relative to traditional case-control or cohort studies. The cost of the test-negative design is the additional, difficult-to-test assumptions that incidence of non-influenza respiratory infections is similar between vaccinated and unvaccinated groups within any stratum of care-seeking behavior, and that influenza VE does not vary across care-seeking strata. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Development and validation of a Pneumocystis jirovecii real-time polymerase chain reaction assay for diagnosis of Pneumocystis pneumonia

    PubMed Central

    Church, Deirdre L; Ambasta, Anshula; Wilmer, Amanda; Williscroft, Holly; Ritchie, Gordon; Pillai, Dylan R; Champagne, Sylvie; Gregson, Daniel G

    2015-01-01

    BACKGROUND: Pneumocystis jirovecii (PJ), a pathogenic fungus, causes severe interstitial Pneumocystis pneumonia (PCP) among immunocompromised patients. A laboratory-developed real-time polyermase chain reaction (PCR) assay was validated for PJ detection to improve diagnosis of PCP. METHODS: Forty stored bronchoalveolar lavage (BAL) samples (20 known PJ positive [PJ+] and 20 known PJ negative [PJ−]) were initially tested using the molecular assay. Ninety-two sequentially collected BAL samples were then analyzed using an immunofluorescence assay (IFA) and secondarily tested using the PJ real-time PCR assay. Discrepant results were resolved by retesting BAL samples using another real-time PCR assay with a different target. PJ real-time PCR assay performance was compared with the existing gold standard (ie, IFA) and a modified gold standard, in which a true positive was defined as a sample that tested positive in two of three methods in a patient suspected to have PCP. RESULTS: Ninety of 132 (68%) BAL fluid samples were collected from immunocompromised patients. Thirteen of 92 (14%) BALs collected were PJ+ when tested using IFA. A total of 40 BAL samples were PJ+ in the present study including: all IFA positive samples (n=13); all referred PJ+ BAL samples (n=20); and seven additional BAL samples that were IFA negative, but positive using the modified gold standard. Compared with IFA, the PJ real-time PCR had sensitivity, specificity, and positive and negative predictive values of 100%, 91%, 65% and 100%, respectively. Compared with the modified gold standard, PJ real-time PCR had a sensitivity, specificity, and positive and negative predictive values of 100%. CONCLUSION: PJ real-time PCR improved detection of PJ in immunocompromised patients. PMID:26600815

  3. Evaluation of the Ortho-Clinical Diagnostics Vitros ECi Anti-HCV test: comparison with three other methods.

    PubMed

    Watterson, Jeannette M; Stallcup, Paulina; Escamilla, David; Chernay, Patrick; Reyes, Alfred; Trevino, Sylvia C

    2007-01-01

    After observing a high incidence of low positive hepatitis C virus (HCV) antibody screens by the Ortho-Clinical Vitros ECi test (Orthoclinical Diagnostics, Raritan, NJ), we compared results against those obtained using another chemiluminescent analyzer, as well as two U.S. Food and Drug Administration (FDA)-approved confirmatory methodologies. To ascertain the true anti-HCV status of samples deemed low-positive by the Ortho-Clinical Vitros ECi test, we tested samples using the ADVIA Centaur HCV screen test (Siemens Medical Solutions Diagnostics), the Chiron recombinant immunoblot assay (RIBA) test (Chiron Corp., Emeryville, CA), and the Roche COBAS Amplicor HCV qualitative test (Roche Diagnostics, Indianapolis, IN) in a series of studies. Of 94 specimens positive by Vitros ECi, 19% were observed to be negative by Centaur. A separate study of 91 samples with signal-to-cutoff (s/co) values less than 8.0 showed that all but one was negative for HCV ribonucleic acid (RNA). In comparison with RIBA, 100% (77) samples positive by the Vitros ECi test with s/co values less than 12.0 were negative or indeterminate by RIBA. A final study comparing all four methods side-by-side showed 63% disagreement by Centaur for Vitros ECi low-positive samples, 75% disagreement by RIBA, and 97% disagreement by polymerase chain reaction (PCR). In conclusion, the Ortho-Clinical Vitros ECi Anti-HCV test yields a high rate of false-positive results in the low s/co range in our patient population. (c) 2007 Wiley-Liss, Inc.

  4. Investigation of an algorithm for anti HCV EIA reactivity in blood donor screening in Turkey in the absence of nucleic acid amplification screening.

    PubMed

    Karakoc, Ayse Esra; Berkem, Rukiye; Irmak, Hasan; Demiroz, Ali Pekcan; Yenicesu, Idil; Ertugrul, Nigar; Arslan, Önder; Kemahli, Sabri; Yilmaz, Sevinc; Ozcebe, Osman; Kara, Abdurrahman; Ozet, Gulsum; Acikgoz, Ziya Cibali; Acikgoz, Tulin

    2017-10-01

    In this study we aimed to propose an algorithm for initial anti HCV EIA reactive blood donations in Turkey where nucleic acid amplification tests are not yet obligatory for donor screening. A total of 416 anti HCV screening test reactive donor samples collected from 13 blood centers from three cities in Turkey were tested in duplicate by Ortho HCV Ab Version 3.0 and Radim HCV Ab. All the repeat reactive samples were tested by INNO-LIA HCV Ab 3.0 or Chiron RIBA HCV 3.0 and Abbott Real Time HCV. Intra-assay correlations were calculated with Pearson r test. ROC analysis was used to study the relationship between EIA tests and the confirmatory tests. The number of repeat reactive results with Ortho EIA were 221 (53.1%) whereas that of microEIA, 62 (14.9%). Confirmed positivity rate was 14.6% (33/226) by RIBA and 10.6% (24/226) by NAT. Reactive PCR results were predicted with 100% sensitivity and 95% specificity with S/CO levels of 8.1 with Ortho EIA and 3.4 with microEIA. Repeat reactivity rates declined with a second HCV antibody assay. Samples repeat reactive with one HCV antibody test and negative with the other were all NAT negative. All the NAT reactive samples were RIBA positive. None of the RIBA indeterminate or negative samples were NAT reactive. Considering the threshold values for EIA kits determined by ROC analysis NAT was decided to be performed for the samples above the threshold value and a validated supplemental HCV antibody test for the samples below. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings.

    PubMed

    Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck

    2015-05-14

    Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false negative results due to seroconversion or misclassification by the lower sensitivity dilution test. Further research is needed to determine if these results can be replicated in other settings. ClinicalTrials.gov, NCT01716299 .

  6. A rapid chemiluminescent slot blot immunoassay for the detection and quantification of Clostridium botulinum neurotoxin type E, in cultures.

    PubMed

    Cadieux, Brigitte; Blanchfield, Burke; Smith, James P; Austin, John W

    2005-05-01

    A simple, rapid, cost-effective in vitro slot blot immunoassay was developed for the detection and quantification of botulinum neurotoxin type E (BoNT/E) in cultures. Culture supernatants of 36 strains of clostridia, including 12 strains of Clostridium botulinum type E, 12 strains of other C. botulinum neurotoxin serotypes, and 12 strains of other clostridial species were tested. Samples containing BoNT/E were detected using affinity-purified polyclonal rabbit antisera prepared against BoNT/E with subsequent detection of secondary antibodies using chemiluminescence. All strains of C. botulinum type E tested positive, while all non C. botulinum type E strains tested negative. The sensitivity of the slot blot immunoassay for detection of BoNT/E was approximately four mouse lethal doses (MLD). The intensity of chemiluminescence was directly correlated with the concentration of BoNT/E up to 128 MLD, allowing quantification of BoNT/E between 4 and 128 MLD. The slot blot immunoassay was compared to the mouse bioassay for detection of BoNT/E using cultures derived from fish samples inoculated with C. botulinum type E, and cultures derived from naturally contaminated environmental samples. A total of 120 primary enrichment cultures derived from fish samples, of which 103 were inoculated with C. botulinum type E, and 17 were uninoculated controls, were assayed. Of the 103 primary enrichment cultures derived from inoculated fish samples, all were positive by mouse bioassay, while 94 were also positive by slot blot immunoassay, resulting in a 7.5% false-negative rate. All 17 primary enrichment cultures derived from the uninoculated fish samples were negative by both mouse bioassay and slot blot immunoassay. A total of twenty-six primary enrichment cultures derived from environmental samples were tested by mouse bioassay and slot blot immunoassay. Of 13 primary enrichment cultures positive by mouse bioassay, 12 were also positive by slot blot immunoassay, resulting in a 3.8% false-negative rate. All 13 primary enrichment cultures that tested negative by mouse bioassay also tested negative by slot blot immunoassay. The slot blot immunoassay could be used routinely as a positive screen for BoNT/E in primary enrichment cultures, and could be used as a replacement for the mouse bioassay for pure cultures.

  7. Routine screening of blood donations at Qingdao central blood bank, China, for hepatitis B virus (HBV) DNA with a real-time, multiplex nucleic acid test for HBV, hepatitis C virus, and human immunodeficiency virus Types 1 and 2.

    PubMed

    Yang, Zhongsi; Xu, Lei; Liu, Li; Feng, Qiuxia; Zhang, Longmu; Ma, Weijuan; Saldanha, John; Wang, Mingmin; Zhao, Lin

    2013-10-01

    The Roche cobas TaqScreen MPX test was used to evaluate the rate of hepatitis B surface antigen (HBsAg)-negative donations that were hepatitis B virus (HBV) DNA reactive from June 2010 to January 2011 in Qingdao, China. HBsAg-negative samples from 65,800 voluntary blood donors were tested with the cobas TaqScreen MPX test in pools of 6 on the Roche cobas s 201 blood screening platform. Samples positive for HBV DNA and negative for HBsAg were quantitated with the Roche COBAS AmpliPrep/COBAS TaqMan HBV test. In addition, serologic tests for HBsAg, hepatitis B surface antibody, anti-hepatitis B core antigen (anti-HBc), anti-hepatitis B e antigen (anti-HBe), and hepatitis B e antigen (HBe) were done using the Roche electrochemiluminescence immunoassay. A total of 80 nucleic acid amplification technology (NAT) test-reactive pools were identified and 59 pools (74%) resolved to a reactive sample. All samples were HBV DNA reactive and the viral load in each sample was quantitated. The viral loads of the samples ranged from less than 20 to 34,600 IU/mL; 13 samples (22%) had viral loads of more than 20 IU/mL, 27 samples (45.8%) had viral loads of less than 20 IU/mL, and 19 samples (32.2%) had undetectable viral loads. Of the 59 NAT-reactive samples, 40 (67.8%) were anti-HBc positive. Fifteen of the 59 samples could not be confirmed as NAT reactive either by an alternative NAT test or by serology. The HBV NAT yield in blood donors in Qingdao is 0.06% (38/65,800). This study confirmed the value of NAT for interdicting HBV-positive donations and preventing transfusion-transmitted HBV infections. © 2013 American Association of Blood Banks.

  8. The Role of Shame as a Mediator between Anti-Black Racial Identity Attitudes and Negative Affect in a Sample of African American College Students

    ERIC Educational Resources Information Center

    Jefferson, Stephen

    2011-01-01

    A sample of 168 African American undergraduates was surveyed to clarify past findings demonstrating a consistent relationship between endorsing negative attitudes about being African American and experiencing negative affect. Specifically, shame was tested as a mediator between participants' endorsement of preencounter attitudes (i.e., anti-Black…

  9. Statistical inference involving binomial and negative binomial parameters.

    PubMed

    García-Pérez, Miguel A; Núñez-Antón, Vicente

    2009-05-01

    Statistical inference about two binomial parameters implies that they are both estimated by binomial sampling. There are occasions in which one aims at testing the equality of two binomial parameters before and after the occurrence of the first success along a sequence of Bernoulli trials. In these cases, the binomial parameter before the first success is estimated by negative binomial sampling whereas that after the first success is estimated by binomial sampling, and both estimates are related. This paper derives statistical tools to test two hypotheses, namely, that both binomial parameters equal some specified value and that both parameters are equal though unknown. Simulation studies are used to show that in small samples both tests are accurate in keeping the nominal Type-I error rates, and also to determine sample size requirements to detect large, medium, and small effects with adequate power. Additional simulations also show that the tests are sufficiently robust to certain violations of their assumptions.

  10. From IEDs to AIDS? Detection of HIV in human corpses by rapid screening tests after suspected intentional transmission in terrorist attacks.

    PubMed

    Frickmann, Hagen; Wulff, B; Loderstædt, U; Hagen, R M; Sturm, D; Polywka, S

    2013-12-01

    We evaluated the feasibility of intentional transmission of HIV by means of suicide bombing and rape as a terrorist tactic in asymmetric conflicts by evaluating the recognised optimum conditions for biological warfare. We also estimated the suitability of a fourth-generation rapid test for HIV detection in the blood of dead terrorists killed in the completion of their mission. The feasibility of deliberate transmission of HIV for terroristic ends was evaluated on the basis of published experience from passive biological warfare research. In addition, blood from four recently deceased HIV-positive patients and four HIV-negative control corpses, stored at 4°C in a mortuary, was analysed at 12, 24, 36 and 48 h postmortem by rapid serological testing. The feasibility of HIV infection for terroristic purposes was established. The fourth-generation HIV rapid test we evaluated identified all HIV-positive samples and was negative for all HIV-negative samples. Rapid HIV testing from the remains of dead terrorists in the deployed military environment is possible. Samples should be acquired quickly, basic sample preparation is advisable and consequent decisions concerning postexposure prophylaxis should take into account the diagnostic gap in early infections.

  11. [Evaluation of the diagnostic performance of Xpert MTB/RIF test for the detection of Mycobacterium tuberculosis and rifampin resistance in clinical samples].

    PubMed

    Gürsoy, Nafia Canan; Yakupoğulları, Yusuf; Tekerekoğlu, Mehmet Sait; Otlu, Barış

    2016-04-01

    Rapid and accurate detection of active tuberculosis (TB) cases is one of the most important goal of tuberculosis control programme. For this purpose, new methods are being developed to isolate, serotype and determine the drug resistance of the agent. Xpert MTB/RIF test (CepheidGeneXpert® System, USA) that has been recently developed, is a real-time polymerase chain reaction-based method which detects Mycobacterium tuberculosis complex and resistance of the strain to rifampicin (RIF) from the clinical sample directly within a couple of hours. However, there are not sufficient data about the performance of that test for extrapulmonary samples and pulmonary samples other than sputum. The aims of this study were to investigate the sensitivity, specificity, positive and negative predictive values of Xpert MTB/RIF test in detection of M. tuberculosis and the performance in the determination of rifampicin resistance of the isolates from pulmonary and extrapulmonary clinical samples. A total of 2160 clinical samples, in which 1141 (52.8%) were pulmonary and 1019 (47.2%) were extrapulmonary samples, sent to our laboratory between July 2013 to December 2014, were included in the study. Sixty seven of the evaluated samples (3.1%) were positive with microscopy (acid-fast stain; AFS), 116 samples (5.1%) were positive with culture and 98 samples (4.5%) were positive with Xpert MTB/RIF test. When the culture was considered as the reference method, the sensitivity and specificity of Xpert MTB/RIF test were determined as 73.3% and 99.3%, respectively for all samples; 77.5% and 99.5%, respectively for pulmonary samples and 63.9% and 99.2%, respectively for extrapulmonary samples. Among AFS positive samples, the sensitivity was 100% and specificity was 66.7%; whereas among AFS negative samples those values were 40.4% and 99.4%, respectively. Among all the samples involved in the study, RIF resistance was determined only in three samples with Xpert MTB/ RIF test and that was also proved phenotypically (100% concordance). According to mycobacterial culture results, positive and negative predictive values of Xpert MTB/RIF test were determined as 86.7% and 98.5%, respectively for all samples. Those were determined as 92.5% and 98.3%, respectively for extrapulmonary samples and were determined as 74.2 and 98.7%, respectively for pulmonary samples. According to the results obtained in our study, sensitivity of Xpert MTB/RIF test for extrapulmonary samples was found to be at moderate level; sensitivity of the test was found to be decreased especially in AFS negative samples with less bacilli load. Nonetheless, specificity of Xpert MTB/RIF test to the agent in all samples was found to be extremely high. In our study, although RIF-resistant strains were detected in few of the samples, Xpert MTB/ RIF test could differentiate all resistant and sensitive strains. Additionally, detection of M. tuberculosis and RIF resistance in our laboratory takes approximately 20.96 days with culture, this period decreases to a couple of hours with Xpert MTB/RIF test. Because of the advantages such as being practical, rapid and requiring minimal safety measures, it was concluded that Xpert MTB/RIF test may contribute to rapid diagnosis of TB also in extrapulmonary samples, with the confirmation of culture method.

  12. Evaluation of new monoclonal antibody-based latex agglutination test for detection of cryptococcal polysaccharide antigen in serum and cerebrospinal fluid.

    PubMed Central

    Kiska, D L; Orkiszewski, D R; Howell, D; Gilligan, P H

    1994-01-01

    We evaluated the performance of CRYPTO-LEX (Trinity Laboratories, Inc., Raleigh, N. C.), a new mouse immunoglobulin M monoclonal antibody latex agglutination reagent which reacts with the capsular polysaccharide of the four serogroups of Cryptococcus neoformans. This test was compared with CALAS (Meridian Diagnostics, Cincinnati, Ohio) for the ability to detect cryptococcal antigen in serum and cerebrospinal fluid (CSF). A total of 580 clinical specimens (327 serum and 253 CSF samples), primarily from human immunodeficiency virus-infected patients, were tested in this study. Sixty-seven specimens (44 serum and 23 CSF samples) were positive for cryptococcal antigen with both tests, and 511 (282 serum and 229 CSF samples) were negative. The two latex reagents agreed for 326 of 327 serum specimens (44 positives and 282 negatives). One serum specimen with a titer of 1:2 was CALAS positive but CRYPTO-LEX negative. The titer correlation coefficient for the two tests was 0.884 when two highly discordant serum specimens were eliminated from analysis of the data. The two latex tests agreed for 252 of 253 CSF specimens (23 positives and 229 negatives). One specimen with a titer of 1:2 was positive with CALAS and negative by CRYPTO-LEX. The correlation coefficient of the two tests for CSF titers was 0.886. The sensitivity and specificity of CRYPTO-LEX were 97 and 100%, respectively, with a 99.6% correlation with CALAS. These data show that the performance of CRYPTO-LEX is comparable to that of CALAS for detection of cryptococcal antigen in serum and CSF. PMID:7814566

  13. [Serological examinations for swine vesicular disease (SVD) in a closed pig breeding herd using ELISA].

    PubMed

    Pannwitz, Gunter; Haas, Bernd; Hoffmann, Bernd; Fischer, Sebastian

    2009-01-01

    In a closed pig establishment housing about 18,000 pigs, 2895 gilts were tested pre-export for SVD (swine vesicular disease) antibodies using Ceditest/PrioCHECK SVDV-AB ELISA. 130 gilts (4.5%) tested positive. In addition, 561 animals of this farm were sampled per random for SVD serology. One in 241 weaners (0.4%), eight in 150 gilts (5.3%) and 18 in 170 (10.6%) pregnant sows tested ELISA SVD-antibody positive. Of the ELISA positive samples, 23 tested positive in VNT (virus neutralization test). Of these, 20 VNT-positive animals were re-sampled two weeks later and re-tested via ELISA and VNT in different laboratories, displaying falling titres with one to two animals remaining VNT-positive. Epidemiological investigations and clinical examinations on site did not yield any evidence for SVD. 745 faecal samples taken from individual pigs and collected from pens tested negative in SVDV-RNA-PCR. 40 of these samples tested negative in virus isolation on cell culture. Pathological examinations on fallen pigs did not reveal any evidence for SVD either. After comparing our ELISA results with data recorded in the ELISA validation by Chenard et al. (1998), we propose that the published test performance is perhaps not currently applicable for the commercial test. Provided that SVD-antibody negative pigs were tested, a specificity of 99.6% in weaners, 95.5% in gilts and 89.4% in pregnant sows would appear to be more appropriate for the Ceditest/PrioCHECK SVDV-AB ELISA. Details are provided for all examined pigs regarding husbandry, breed, age, weeks pregnant and previous vaccinations. The results of other serological tests on the same sera are given. Possible clusterings of false-positive SVD-ELISA results are discussed.

  14. Cluster Randomized Test-Negative Design (CR-TND) Trials: A Novel and Efficient Method to Assess the Efficacy of Community Level Dengue Interventions.

    PubMed

    Anders, Katherine L; Cutcher, Zoe; Kleinschmidt, Immo; Donnelly, Christl A; Ferguson, Neil M; Indriani, Citra; O'Neill, Scott L; Jewell, Nicholas P; Simmons, Cameron P

    2018-05-07

    Cluster randomized trials are the gold standard for assessing efficacy of community-level interventions, such as vector control strategies against dengue. We describe a novel cluster randomized trial methodology with a test-negative design, which offers advantages over traditional approaches. It utilizes outcome-based sampling of patients presenting with a syndrome consistent with the disease of interest, who are subsequently classified as test-positive cases or test-negative controls on the basis of diagnostic testing. We use simulations of a cluster trial to demonstrate validity of efficacy estimates under the test-negative approach. This demonstrates that, provided study arms are balanced for both test-negative and test-positive illness at baseline and that other test-negative design assumptions are met, the efficacy estimates closely match true efficacy. We also briefly discuss analytical considerations for an odds ratio-based effect estimate arising from clustered data, and outline potential approaches to analysis. We conclude that application of the test-negative design to certain cluster randomized trials could increase their efficiency and ease of implementation.

  15. [Evaluation of Mascia Brunelli rapid antigen test in the diagnosis of group A streptococcal pharyngitis].

    PubMed

    Barış, Ayşe; Anlıaçık, Nur; Bulut, Mehmet Emin; Deniz, Rıdvan; Yücel, Elif; Aktaş, Elif

    2017-01-01

    Pharyngitis in most cases is due to viral microorganisms however drug therapy without the detection of etiological agent leads to unnecessary use of antibiotics. On the other hand, when the etiologic agent is group A beta-hemolytic streptococci (GAS) it is important to identify the etiologic agent rapidly which will guide the treatment with appropriate antibiotics. The use of highly sensitive rapid tests will contribute significantly to early diagnosis and appropriate therapy. The aim of this study is to evaluate the efficacy of Mascia Brunelli rapid antigen test for the detection of GAS in throat swab samples. A total of 833 throat swab samples submitted to our laboratory with pre-diagnosis of pharyngitis were assessed between June 2016 and August 2016. The samples were simultaneously cultured and tested by rapid Mascia Brunelli Strep-A Card (Mascia Brunelli S.p.a, Italy). For identification, bacitracin sensitivity, PYR test and latex agglutination test in addition to Bruker MALDI-TOF MS (Daltonics, Germany) system were used. The density of GAS growth in the culture was noted. The samples that were false negative with Mascia Brunelli test were re-tested with QuickVue + Strep A Test (Quidel Corporation, San Diego, USA) rapid antigen test. A total of 833 patients, 376 (45.2%) female and 457 (54.8%) male were included in the study. The age range was between 0-94 years with a mean value of 7.86 ± 6.72. 125 (15%) and 94 (11.28%) of the samples were positive with culture and rapid antigen test, respectively. Mascia Brunelli antigen test gave negative results for 31 culture positive samples. Of these 31 samples, 28 were found positive by QuickVue + Strep A antigen test. As a result, the sensitivity of the test was found to be independent of the inoculum effect. The culture positivity rate in patients between 5-15 years was 18.4%. The sensitivity, specificity, positive predictive value, negative predictive value and the accuracy of Mascia Brunelli antigen test, with respect to culture, were 75.2%, 100%, 100%, 95.81% and 96.28%, respectively. In conclusion, the selection of rapid antigen tests with high sensitivity in the diagnosis of GAS pharyngitis will contribute to the prevention of resistance development by appropriate use of antibiotics as well as early diagnosis and appropriate treatment. However, confirmation of negative rapid antigen test results by culture is very important in terms of false diagnosis and prevention of incomplete treatment.

  16. Prevalence of pfhrp2 and/or pfhrp3 Gene Deletion in Plasmodium falciparum Population in Eight Highly Endemic States in India

    PubMed Central

    Bharti, Praveen Kumar; Chandel, Himanshu Singh; Ahmad, Amreen; Krishna, Sri; Udhayakumar, Venkatachalam; Singh, Neeru

    2016-01-01

    Background Plasmodium falciparum encoded histidine rich protein (HRP2) based malaria rapid diagnostic tests (RDTs) are used in India. Deletion of pfhrp2 and pfhrp3 genes contributes to false negative test results, and large numbers of such deletions have been reported from South America, highlighting the importance of surveillance to detect such deletions. Methods This is the first prospective field study carried out at 16 sites located in eight endemic states of India to assess the performance of PfHRP2 based RDT kits used in the national malaria control programme. In this study, microscopically confirmed P. falciparum but RDT negative samples were assessed for presence of pfhrp2, pfhrp3, and their flanking genes using PCR. Results Among 1521 microscopically positive P. falciparum samples screened, 50 were negative by HRP2 based RDT test. Molecular testing was carried out using these 50 RDT negative samples by assuming that 1471 RDT positive samples carried pfhrp2 gene. It was found that 2.4% (36/1521) and 1.8% (27/1521) of samples were negative for pfhrp2 and pfhrp3 genes, respectively. However, the frequency of pfhrp2 deletions varied between the sites ranging from 0–25% (2.4, 95% CI; 1.6–3.3). The frequency of both pfhrp2 and pfhrp3 gene deletion varied from 0–8% (1.6, 95% CI; 1.0–2.4). Conclusion This study provides evidence for low level presence of pfhrp2 and pfhrp3 deleted P. falciparum parasites in different endemic regions of India, and periodic surveillance is warranted for reliable use of PfHRP2 based RDTs. PMID:27518538

  17. [The negative temperature effect of UV absorbance on C60 in different solvents].

    PubMed

    Yang, Tao; Zeng, Fan-qin; Ge, Qi; Xiong, Qian; Guo, Feng; Zhang, Xun-gao

    2004-02-01

    Ultraviolet Absorption Spectrum of Difference in Temperature (UVSDT) of C60 was studied in different solvents by UV-240 ultraviolet-visible spectrophotometer. Two samples were tested, one of which acted as reference sample and the other as ready test sample. During the period of the experiment, the temperature of the reference sample remained constant, while that of the ready test sample was changed to obtain difference in temperature. The two samples were scanned in succession by UV-240 ultraviolet-visible spectrophotometer using a certain range of wavelength. By changing the temperature of the ready test sample, we can get the ultraviolet absorption spectrum changing curve with temperature differential. In addition, the curve was studied by putting C60 in different solvents (alcohol, cyclohexane, n-hexane and 2-propanol). The curve indicates that the intensity of the absorption peak wavelength of C60 decreased with increasing the temperature of the sample, and a negative peak was observed in UVSDT. And the greater the difference in temperature, the higher the intensity of the negative peak. The result reflects that the structure of C60 depends strongly on its temperature, and the dependent relationship is closely related to the type of pi-pi electron transition. So it's valuable to test the absorption rate of C60 and obtain the changing curve in real time. It'll help us to separate, purify, analyze, and characterize C60. And it'll also help to do research on the mechanism of the chemical reactions, which take place in solvents, as well as to improve veracity.

  18. Monitoring cocaine use and abstinence among cocaine users for contingency management interventions.

    PubMed

    Holtyn, August F; Knealing, Todd W; Jarvis, Brantley P; Subramaniam, Shrinidhi; Silverman, Kenneth

    2017-06-01

    During contingency management interventions, reinforcement of cocaine abstinence is arranged by delivering an incentive when a urine sample tests cocaine-negative. The use of qualitative versus quantitative urinalysis testing may have important implications for effects on cocaine abstinence. Qualitative testing (i.e., testing that solely identifies whether a particular substance is present or absent) may not detect short-term cocaine abstinence because a single instance of cocaine use can result in cocaine-positive urine over many days. Quantitative testing (i.e., testing that identifies how much of a substance is present) may be more sensitive to short-term cocaine abstinence; however, the selection of a criterion for distinguishing new use versus carryover from previous use is an important consideration. The present study examined benzoylecgonine concentrations, the primary metabolite of cocaine, in urine samples collected three times per week for 30 weeks from 28 cocaine users who were exposed to a cocaine abstinence contingency. Of the positive urine samples (benzoylecgonine concentration >300 ng/ml), 29%, 21%, 14%, and 5% of the samples decreased in benzoylecgonine concentration by more than 20%, 40%, 60%, and 80% per day, respectively. As the size of the decrease increased, the likelihood of that sample occurring during a period leading to a cocaine-negative urine sample (benzoylecgonine concentration ≤300 ng/ml) also increased. The number of days required to produce a cocaine-negative sample following a positive sample ranged from 1 to 10 days and was significantly correlated with the starting benzoylecgonine level ( r = 0.43, p < 0.001). The present analyses may aid in the development of procedures that allow for the precise reinforcement of recent cocaine abstinence during contingency management interventions.

  19. Detection of Helicobacter pylori by Real-Time PCR for 16s rRNA in Stools of NonInfected Healthy Children, Using ELISA Antigen Stool Test as the Gold Standard.

    PubMed

    George, Sergio; Mamani, Nora; Lucero, Yalda; Torres, Juan Pablo; Farfán, Mauricio; Lagomarcino, Anne J; Orellana, Andrea; O'Ryan, Miguel

    2016-12-01

    We previously detected Helicobacter pylori infection by stool antigen ELISA assay in 33-41% of asymptomatic Chilean children between 2-3 years of age, of which 11-20% had a transient infection and 21-22% a persistent infection. A total of 88% of ELISA-positive samples were also rtPCR positive, while 37/133 (33%) of ELISA-negative stool samples were rtPCR positive. The significance of a ELISA-negative/rtPCR-positive sample requires clarification. We aimed to determine whether rtPCR is able to detect persistent infections not detected by ELISA. We selected 36 children with an ELISA-negative/rtPCR-positive stool sample, of which 25 were never H. pylori infected according to ELISA, and 11 had a transient infection with an ELISA-positive sample before or after the discordant sample. At least two additional consecutive ELISA-negative samples per child were tested in duplicate by rtPCR for the 16s rRNA gene. A total of 14 of 78 (17.9%) rtPCR reactions were positive, but only 4/78 (5.1%) were positive in both duplicates, representing a total of 3/36 (8.3%) children with an additional rtPCR-positive sample, only one of whom was persistently negative by ELISA. One child with a transient infection had two positive rtPCR reactions despite negative ELISA samples. In H. pylori noninfected or transiently infected children, as determined by stool ELISA, additional ELISA-negative/rtPCR-positive stool samples were found in 8.3% of children, but a possible persistent infection was only identified in 2.7% of children. Thus, the characterization of infection dynamics in children is not being misrepresented by application of stool ELISA. Furthermore, rtPCR does not significantly improve dynamic characterization. © 2016 John Wiley & Sons Ltd.

  20. Bayesian inference for disease prevalence using negative binomial group testing

    PubMed Central

    Pritchard, Nicholas A.; Tebbs, Joshua M.

    2011-01-01

    Group testing, also known as pooled testing, and inverse sampling are both widely used methods of data collection when the goal is to estimate a small proportion. Taking a Bayesian approach, we consider the new problem of estimating disease prevalence from group testing when inverse (negative binomial) sampling is used. Using different distributions to incorporate prior knowledge of disease incidence and different loss functions, we derive closed form expressions for posterior distributions and resulting point and credible interval estimators. We then evaluate our new estimators, on Bayesian and classical grounds, and apply our methods to a West Nile Virus data set. PMID:21259308

  1. Time perspective in hereditary cancer: psychometric properties of a short form of the Zimbardo Time Perspective Inventory in a community and clinical sample.

    PubMed

    Wakefield, Claire E; Homewood, Judi; Taylor, Alan; Mahmut, Mehmet; Meiser, Bettina

    2010-10-01

    We aimed to assess the psychometric properties of a 25-item short form of the Zimbardo Time Perspective Inventory in a community sample (N = 276) and in individuals with a strong family history of cancer, considering genetic testing for cancer risk (N = 338). In the community sample, individuals with high past-negative or present-fatalistic scores had higher levels of distress, as measured by depression, anxiety, and aggression. Similarly, in the patient sample, past-negative time perspective was positively correlated with distress, uncertainty, and postdecision regret when making a decision about genetic testing. Past-negative-oriented individuals were also more likely to be undecided about, or against, genetic testing. Hedonism was associated with being less likely to read the educational materials they received at their clinic, and fatalism was associated with having lower knowledge levels about genetic testing. The assessment of time perspective in individuals at increased risk of cancer can provide valuable clinical insights. However, further investigation of the psychometric properties of the short form of this scale is warranted, as it did not meet the currently accepted criteria for psychometric validation studies.

  2. Sample features associated with success rates in population-based EGFR mutation testing.

    PubMed

    Shiau, Carolyn J; Babwah, Jesse P; da Cunha Santos, Gilda; Sykes, Jenna R; Boerner, Scott L; Geddie, William R; Leighl, Natasha B; Wei, Cuihong; Kamel-Reid, Suzanne; Hwang, David M; Tsao, Ming-Sound

    2014-07-01

    Epidermal growth factor receptor (EGFR) mutation testing has become critical in the treatment of patients with advanced non-small-cell lung cancer. This study involves a large cohort and epidemiologically unselected series of EGFR mutation testing for patients with nonsquamous non-small-cell lung cancer in a North American population to determine sample-related factors that influence success in clinical EGFR testing. Data from consecutive cases of Canadian province-wide testing at a centralized diagnostic laboratory for a 24-month period were reviewed. Samples were tested for exon-19 deletion and exon-21 L858R mutations using a validated polymerase chain reaction method with 1% to 5% detection sensitivity. From 2651 samples submitted, 2404 samples were tested with 2293 samples eligible for analysis (1780 histology and 513 cytology specimens). The overall test-failure rate was 5.4% with overall mutation rate of 20.6%. No significant differences in the failure rate, mutation rate, or mutation type were found between histology and cytology samples. Although tumor cellularity was significantly associated with test-success or mutation rates in histology and cytology specimens, respectively, mutations could be detected in all specimen types. Significant rates of EGFR mutation were detected in cases with thyroid transcription factor (TTF)-1-negative immunohistochemistry (6.7%) and mucinous component (9.0%). EGFR mutation testing should be attempted in any specimen, whether histologic or cytologic. Samples should not be excluded from testing based on TTF-1 status or histologic features. Pathologists should report the amount of available tumor for testing. However, suboptimal samples with a negative EGFR mutation result should be considered for repeat testing with an alternate sample.

  3. Evaluation of the human immunodeficiency virus type 1 and 2 antibodies detection in dried whole blood spots (DBS) samples.

    PubMed

    Castro, Andréa Cauduro de; Borges, Luiz Gustavo dos Anjos; Souza, Ricardo da Silva de; Grudzinski, Melina; D'Azevedo, Pedro Alves

    2008-01-01

    Human Immunodeficiency Virus Type 1 and 2 antibodies detection was performed in 457 dried whole blood spots samples (S&S 903). Q-Preven HIV 1+2 was the screening test used. The results were compared with the gold standard serum tests by ELISA (Cobas Core e Axsym HIV1/2 gO) and immunofluorescence was the definitive confirmatory test. The samples were obtained from the Hospital Nossa Senhora da Conceição in Porto Alegre, RS - Brazil, through whole blood transfer to filter paper card and sent to Caxias do Sul, RS-Brazil where the tests were performed. The dried whole blood spot stability was evaluated with two different panels. The first one was composed of five negative and five positive samples stored at room temperature, 4 degrees C, -20 degrees C and -70 degrees C, while the second was composed of two negative and three positive samples stored at 37 degrees C (humidity <50%). Each sample was screened every week for six weeks. These measurement results didn't show variation during the study period. The detected sensibility was 100%, specificity was 99.6%, the positive predictive value was 99.5% and negative predictive values were 100%. The results demonstrated high performance characteristics, opening a new perspective of dried whole blood spot utilization in HIV screening diagnosis.

  4. Evaluation of the Sysmex UF1000i flow cytometer for ruling out bacterial urinary tract infection.

    PubMed

    De Rosa, Rita; Grosso, Shamanta; Bruschetta, Graziano; Avolio, Manuela; Stano, Paola; Modolo, Maria Luisa; Camporese, Alessandro

    2010-08-05

    Urine culture is one of the most frequently requested tests in microbiology, and it represents the gold standard for the diagnosis of UTIs. Considering the high prevalence of negative results and the long TAT of the culture test, the use of a rapid and reliable screening method is becoming more and more important, as it reduces the workload, the TAT of negative results, and above all, unnecessary antibiotic prescription. The Sysmex UF1000i is a new urine flow cytometry analyzer capable of quantifying urinary particles, including BACT, WBCs, and YLCs. To evaluate the analytical performance of the UF1000i as a method for ruling out UTIs, we examined 1349 urine samples and compared the UF1000i results with standard urine culture results. With instrument cut-off values of 170BACTx10(6)/L and 150WBCsx10(6)/L, we obtained a sensitivity of 98.8%, a specificity of 76.5%, a NPV of 99.5%, and four false negative results (1.2%), avoiding the culture of 57.1% of samples. The Sysmex UF1000i was capable of improving the efficiency of a routine microbiology laboratory by processing 100samples/h and providing negative results in a few minutes, thus reducing unnecessary testing with an acceptable number of false negative results. In addition, the preliminary evaluation of B_FSC and B_FLH parameters from bacteria histograms seems to be useful for the distinction of bacterial strains detected (Gram-negatives versus Gram-positives). In fact when B_FSC was less than 30 ch, it allowed the distinction of Gram-negative bacteria in 97% of the samples. Copyright 2010 Elsevier B.V. All rights reserved.

  5. Validation of the 3M molecular detection system for the detection of listeria in meat, seafood, dairy, and retail environments.

    PubMed

    Fortes, Esther D; David, John; Koeritzer, Bob; Wiedmann, Martin

    2013-05-01

    There is a continued need to develop improved rapid methods for detection of foodborne pathogens. The aim of this project was to evaluate the 3M Molecular Detection System (3M MDS), which uses isothermal DNA amplification, and the 3M Molecular Detection Assay Listeria using environmental samples obtained from retail delicatessens and meat, seafood, and dairy processing plants. Environmental sponge samples were tested for Listeria with the 3M MDS after 22 and 48 h of enrichment in 3M Modified Listeria Recovery Broth (3M mLRB); enrichments were also used for cultural detection of Listeria spp. Among 391 samples tested for Listeria, 74 were positive by both the 3M MDS and the cultural method, 310 were negative by both methods, 2 were positive by the 3M MDS and negative by the cultural method, and one sample was negative by the 3M MDS and positive by the cultural method. Four samples were removed from the sample set, prior to statistical analyses, due to potential cross-contamination during testing. Listeria isolates from positive samples represented L. monocytogenes, L. innocua, L. welshimeri, and L. seeligeri. Overall, the 3M MDS and culture-based detection after enrichment in 3M mLRB did not differ significantly (P < 0.05) with regard to the number of positive samples, when chi-square analyses were performed for (i) number of positive samples after 22 h, (ii) number of positive samples after 48 h, and (iii) number of positive samples after 22 and/or 48 h of enrichment in 3M mLRB. Among 288 sampling sites that were tested with duplicate sponges, 67 each tested positive with the 3M MDS and the traditional U.S. Food and Drug Administration Bacteriological Analytical Manual method, further supporting that the 3M MDS performs equivalently to traditional methods when used with environmental sponge samples.

  6. Anomaly detection for medical images based on a one-class classification

    NASA Astrophysics Data System (ADS)

    Wei, Qi; Ren, Yinhao; Hou, Rui; Shi, Bibo; Lo, Joseph Y.; Carin, Lawrence

    2018-02-01

    Detecting an anomaly such as a malignant tumor or a nodule from medical images including mammogram, CT or PET images is still an ongoing research problem drawing a lot of attention with applications in medical diagnosis. A conventional way to address this is to learn a discriminative model using training datasets of negative and positive samples. The learned model can be used to classify a testing sample into a positive or negative class. However, in medical applications, the high unbalance between negative and positive samples poses a difficulty for learning algorithms, as they will be biased towards the majority group, i.e., the negative one. To address this imbalanced data issue as well as leverage the huge amount of negative samples, i.e., normal medical images, we propose to learn an unsupervised model to characterize the negative class. To make the learned model more flexible and extendable for medical images of different scales, we have designed an autoencoder based on a deep neural network to characterize the negative patches decomposed from large medical images. A testing image is decomposed into patches and then fed into the learned autoencoder to reconstruct these patches themselves. The reconstruction error of one patch is used to classify this patch into a binary class, i.e., a positive or a negative one, leading to a one-class classifier. The positive patches highlight the suspicious areas containing anomalies in a large medical image. The proposed method has been tested on InBreast dataset and achieves an AUC of 0.84. The main contribution of our work can be summarized as follows. 1) The proposed one-class learning requires only data from one class, i.e., the negative data; 2) The patch-based learning makes the proposed method scalable to images of different sizes and helps avoid the large scale problem for medical images; 3) The training of the proposed deep convolutional neural network (DCNN) based auto-encoder is fast and stable.

  7. Serological and molecular diagnostic tests for canine visceral leishmaniasis in Brazilian endemic area: one out of five seronegative dogs are infected.

    PubMed

    Lopes, E G; Sevá, A P; Ferreira, F; Nunes, C M; Keid, L B; Hiramoto, R M; Ferreira, H L; Oliveira, T M F S; Bigotto, M F D; Galvis-Ovallos, F; Galati, E A B; Soares, R M

    2017-09-01

    Euthanasia of infected dogs is one of the measures adopted in Brazil to control visceral leishmaniasis (VL) in endemic areas. To detect infected dogs, animals are screened with the rapid test DPP® Visceral Canine Leishmaniasis for detection of antibodies against K26/K39 fusion antigens of amastigotes (DPP). DPP-positives are confirmed with an immunoenzymatic assay probing soluble antigens of promastigotes (ELISA), while DPP-negatives are considered free of infection. Here, 975 dogs from an endemic region were surveyed by using DPP, ELISA and real-time PCR (qPCR) for the diagnosis of VL. When DPP-negative dogs were tested by qPCR applied in blood and lymph node aspirates, 174/887 (19·6%) were positive in at least one sample. In a second sampling using 115 cases, the DPP-negative dogs were tested by qPCR in blood, lymph node and conjunctival swab samples, and 36/79 (45·6%) were positive in at least one sample. Low-to-moderate pairwise agreement was observed between all possible pair of tests. In conclusion, the official diagnosis of VL in dogs in Brazilian endemic areas failed to accuse an expressive number of infected animals and the impact of the low accuracy of serological tests in the success of euthanasia-based measure for VL control need to be assessed.

  8. Large-Scale Evaluation of the Immuno-Mycologics Lateral Flow and Enzyme-Linked Immunoassays for Detection of Cryptococcal Antigen in Serum and Cerebrospinal Fluid

    PubMed Central

    Hansen, Jessica; Slechta, E. Susan; Gates-Hollingsworth, Marcellene A.; Neary, Brandon; Barker, Adam P.; Bauman, Sean; Kozel, Thomas R.

    2013-01-01

    Cryptococcosis is a systemic infection caused by the pathogenic yeasts Cryptococcus neoformans and C. gattii. Detection of cryptococcal capsular antigen (CrAg) in serum and cerebrospinal fluid (CSF) plays an important diagnostic role. We prospectively compared the new Immuno-Mycologics Inc. (IMMY) lateral flow assay (LFA) and enzyme immunoassay (EIA) to our current CrAg test (Premier EIA; Meridian Bioscience Inc.). Discordant samples were retested with the latex-Cryptococcus antigen test (IMMY) and using serotype-specific monoclonal antibodies (MAbs). A total of 589 serum and 411 CSF specimens were tested in parallel. Qualitative agreement across assays was 97.7%. In all, 56 (41 serum and 15 CSF) samples were positive and 921 (527 serum and 394 CSF) samples were negative by all three assays. The 23 discrepant specimens were all Meridian EIA negative. Of 23 discordant specimens, 20 (87.0%) were positive by both the IMMY LFA and EIA, 2 were LFA positive only, and 1 was EIA positive only. Eleven discrepant specimens had adequate volume for latex agglutination (LA) testing; 8 were LA positive, and 3 were LA negative. LA-negative samples (2 CSF samples and 1 serum) had low IMMY LFA/EIA titers (≤1:10). Serotype-specific MAb analysis of the LA-positive samples suggested that these specimens contained CrAg epitopes similar to those of serotype C strains. In conclusion, the IMMY assays showed excellent overall concordance with the Meridian EIA. Assay performance differences were related to issues of analytic sensitivity and possible serotype bias. Incomplete access to patient-level data combined with low specimen volumes limited our ability to fully resolve discrepant results. PMID:23114703

  9. Large-scale evaluation of the immuno-mycologics lateral flow and enzyme-linked immunoassays for detection of cryptococcal antigen in serum and cerebrospinal fluid.

    PubMed

    Hansen, Jessica; Slechta, E Susan; Gates-Hollingsworth, Marcellene A; Neary, Brandon; Barker, Adam P; Bauman, Sean; Kozel, Thomas R; Hanson, Kimberly E

    2013-01-01

    Cryptococcosis is a systemic infection caused by the pathogenic yeasts Cryptococcus neoformans and C. gattii. Detection of cryptococcal capsular antigen (CrAg) in serum and cerebrospinal fluid (CSF) plays an important diagnostic role. We prospectively compared the new Immuno-Mycologics Inc. (IMMY) lateral flow assay (LFA) and enzyme immunoassay (EIA) to our current CrAg test (Premier EIA; Meridian Bioscience Inc.). Discordant samples were retested with the latex-Cryptococcus antigen test (IMMY) and using serotype-specific monoclonal antibodies (MAbs). A total of 589 serum and 411 CSF specimens were tested in parallel. Qualitative agreement across assays was 97.7%. In all, 56 (41 serum and 15 CSF) samples were positive and 921 (527 serum and 394 CSF) samples were negative by all three assays. The 23 discrepant specimens were all Meridian EIA negative. Of 23 discordant specimens, 20 (87.0%) were positive by both the IMMY LFA and EIA, 2 were LFA positive only, and 1 was EIA positive only. Eleven discrepant specimens had adequate volume for latex agglutination (LA) testing; 8 were LA positive, and 3 were LA negative. LA-negative samples (2 CSF samples and 1 serum) had low IMMY LFA/EIA titers (≤1:10). Serotype-specific MAb analysis of the LA-positive samples suggested that these specimens contained CrAg epitopes similar to those of serotype C strains. In conclusion, the IMMY assays showed excellent overall concordance with the Meridian EIA. Assay performance differences were related to issues of analytic sensitivity and possible serotype bias. Incomplete access to patient-level data combined with low specimen volumes limited our ability to fully resolve discrepant results.

  10. Reduced detection by Ziehl-Neelsen method of acid-fast bacilli in sputum samples preserved in cetylpyridinium chloride solution.

    PubMed

    Selvakumar, N; Sudhamathi, S; Duraipandian, M; Frieden, T R; Narayanan, P R

    2004-02-01

    Twelve health facilities implementing the DOTS strategy, and the Tuberculosis Research Centre (TRC), Chennai, India. To determine the detection rates using Ziehl-Neelsen (ZN) and auramine-phenol to stain acid-fast bacilli (AFB) in sputum samples stored in cetylpyridinium chloride (CPC) solution. Two smears were prepared from each of 988 sputum samples collected in CPC and randomly allocated, one to ZN and the other to auramine-phenol staining. All samples were processed for culture of Mycobacterium tuberculosis. A significantly higher proportion of samples were negative using the ZN method compared to the auramine-phenol method (74.5% vs. 61.8%, McNamara's paired chi2 test; P < 0.001). Among 377 samples that were positive using auramine-phenol, 44% were negative using ZN. There were more culture-positive, smear-negative samples in ZN (52.7%) than in auramine-phenol (30%); the difference attained statistical significance (McNemar's paired chi2 test; P < 0.00004). Using ZN, of the 104 smears made immediately after collection, 52 were positive for AFB, of which only 35 (67.3%) were positive after storage in CPC; the reduction in the number of positive smears attained statistical significance (McNemar's paired chi2 test; P = 0.004). Detection of AFB in sputum samples preserved in CPC is significantly reduced using ZN staining.

  11. Application of the BAX for screening/genus Listeria polymerase chain reaction system for monitoring Listeria species in cold-smoked fish and in the smoked fish processing environment.

    PubMed

    Norton, D M; McCamey, M; Boor, K J; Wiedmann, M

    2000-03-01

    The cold-smoked fish industry was used as a model for the development of a system for monitoring Listeria spp. in foods and in the food processing environment. A total of 214 samples including raw fish, fish during the cold-smoking process, finished product, and environmental samples were collected from three processing facilities over two visits to each facility. Samples were screened for Listeria spp. using the BAX for Screening/genus Listeria polymerase chain reaction system (PCR) and by culture. Listeria spp., confirmed by the API Listeria test strip or by a PCR assay targeting the L. monocytogenes hlyA gene, were isolated from a total of 89 (41.6%) samples. Of these, 80 samples also tested positive for Listeria spp. using the BAX system. Specifically, 42 (55.3%) environmental samples (n = 76), 11 (25.6%) raw materials samples (n = 43), 20 (35.1%) samples from fish in various stages of processing (n = 57), and 7 (18.4%) finished product samples (n = 38) tested positive for Listeria spp. using the BAX system. Five (4.0%) of the 125 culture-negative samples yielded BAX system-positive results. Listeria isolates from each of nine culture-positive/BAX system-negative samples yielded a positive reaction when tested in pure culture by the BAX system, suggesting that our false-negative results were likely due to the presence of low Listeria numbers in the initial enrichment as opposed to nonreacting isolates. The employment of alternative enrichment protocols, such as the two-step enrichment recommended by the manufacturer, may increase the sensitivity of the assay.

  12. Is Perceived Control a Critical Factor in Understanding the Negative Relationship between Cognitive Test Anxiety and Examination Performance?

    ERIC Educational Resources Information Center

    Putwain, David W.; Aveyard, Ben

    2018-01-01

    A well established finding is that the cognitive component of test anxiety (worry) is negatively related to examination performance. The present study examined how 3 self-beliefs (academic buoyancy, perceived control, and test competence) moderated the strength of the relationship between worry and examination performance in a sample of 270 final…

  13. House Dust Mite Prevalence in the House of Patients with Atopic Dermatitis in Mashhad, Iran.

    PubMed

    Ziyaei, Toktam; Berenji, Fariba; Jabbari-Azad, Farahzad; Fata, Abdolmajid; Jarahi, Lida; Fereidouni, Mohammad

    2017-06-01

    Being exposed to house dust mites intensifies atopic dermatitis. This study has investigated the contamination rate with Dermatophagoides mites in patient's residential home with atopic dermatitis. In this cross-sectional study, 40 patients took part with atopic dermatitis (positive or negative for mites by prick Dermal Test). Samples were collected from 3 locations (living room, bedroom and bed) by vacuum cleaner. Dust samples (transferred to freezer -20 °C) were examined by direct method and flotation. The data were analyzed using statistical SPSS vr.20 software. Twenty patients of positive prick test included 8 (40%) male and 12 (60%) female. The results of direct observation of mites: 7 cases (35%) in bedding sheets, 6 cases (30%) bedrooms' carpet, 3 cases (15%) living room's carpet. Twenty patients of negative prick test included 8 (40%) male and 12 (60%) female. Only mites were found (5%) in living room's carpets of negative prick test patients. Dermatophagoides pteronyssinus was more frequent than Dermatophagoides farina e. (98% vs 83%). Fifty-five percent of residential homes of prick test positive patients and only 5% of residential homes of prick test negative patients were positive for mite. Sunshine provided home had fewer mites than home where sunshine is not provided. Prick test positive patients used handmade carpets more than machine made ones. In positive prick test patients, mites were found in bed sheet and bedroom's carpet more than negative prick test patient's sheets and carpets.

  14. Reevaluation of confirmatory tests for human T-cell leukemia virus Type 1 using a luciferase immunoprecipitation system in blood donors.

    PubMed

    Furuta, Rika A; Ma, Guangyong; Matsuoka, Masao; Otani, Satoshi; Matsukura, Harumichi; Hirayama, Fumiya

    2015-04-01

    Recently, Japanese Red Cross blood centers have changed the confirmatory test method from an indirect immunofluorescence (IF) technique to Western blotting (WB) for antibodies against human T-cell leukemia virus Type 1 (HTLV-1). In this study, these HTLV-1 tests were assessed using another sensitive method, that is, a luciferase immunoprecipitation system (LIPS), to identify a better confirmatory test for HTLV-1 infection. Plasma samples from 54 qualified donors and 114 HTLV-1 screening-positive donors were tested by LIPS for antibodies against HTLV-1 Gag, Tax, Env, and HBZ recombinant proteins. The donors were categorized into six groups, namely, (Group I) qualified donors, screening positive; (Group II) IF positive; (Group III) IF negative; (Group IV) WB positive; (Group V) WB negative; and (Group VI) screening positive in the previous blood donation, but WB-indeterminate during this study period. In Groups II and IV, all plasma samples tested positive by LIPS for antibodies against Gag and Env proteins. In Group V, all samples tested negative by LIPS, whereas some Group III samples reacted with single or double antigens in LIPS. In Group VI, the LIPS test identified a donor with suspected HTLV-1 infection. The first case of a blood donor with plasma that reacted with HBZ was identified by LIPS. Reevaluation of the current HTLV-1 screening method using the LIPS test showed that both confirmatory tests had similar sensitivity and specificity only when WB indeterminate results were eliminated. LIPS is a promising method for detecting and characterizing HTLV-1 antibodies. © 2014 AABB.

  15. DIFFERENCES IN CULTURAL YIELD OF MYCOBACTERIUM TUBERCULOSIS ON MEDIA PREPARED USING COMMERCIAL AND HOUSEHOLD EGGS.

    PubMed

    Noori, Muhammad Yahya; AJi, Zaheer; Khan, Ghazala; Sharafat, Shaheen; Masroor, Muhammad

    2015-01-01

    Mycobacterial culture is considered as the gold standard for TB diagnosis. It is performed on egg-based media using commercially available eggs to grow Mycobacteria from clinical samples. These eggs are known to contain high concentration of antibiotics, including fluoroquinolones, given to chicken to prevent early mortality. This study was performed to compare Mycobacterial growth on media prepared from commercial and antibiotic free household eggs. Sputum samples from negative (No bacilli in 100 oil immersion field), scanty (1-9 AFB in 100 fields), 1+ (10-99 bacilli per field), 2+ (1-10 bacilli per field) and 3+ (>10 bacilli per field) were inoculated dually on Ogawa medium prepared from commercial and household eggs. Tubes were inspected every fourth day for the appearance of colonies till 60 days. Data tabulations and statistical analysis (F test for variation and unpaired Student's t test) were performed on Microsoft Excel. One microscopically negative sample showed growth on media prepared from household eggs, while all were negative on that prepared from commercial eggs. There were significant differences in time to culture positivity for samples graded 1+ (p = 0.02), 2+ (p = 0.002) and 3+ (p = 0.0003). Commercial eggs containing antibiotics can be a source of false negativity in cultures especially in microscopically negative samples. This can be of special concern in HIV patients who have high smear negativity. It is therefore important to either develop provision of antibiotic free eggs for media preparation or to develop and validate other laboratory investigations for smear negative TB patients.

  16. Microbiology of primary acquired nasolacrimal duct obstruction: simple epiphora, acute dacryocystitis, and chronic dacryocystitis

    PubMed Central

    Pornpanich, Kanograt; Luemsamran, Panitee; Leelaporn, Amornrut; Santisuk, Jiraporn; Tesavibul, Nattaporn; Lertsuwanroj, Buntitar; Vangveeravong, Sumalee

    2016-01-01

    Purpose The aim of this study was to determine the microbiology of primary acquired nasolacrimal duct obstruction (PANDO) and its antimicrobial susceptibilities. Methods Ninety-three patients (100 eyes) diagnosed with PANDO, categorized as acute, chronic dacryocystitis, or simple epiphora, were prospectively enrolled. Lacrimal sac contents were cultured for aerobic and anaerobic bacteria and fungi. Cultured organisms were identified, and antimicrobial susceptibility testing was performed for aerobic bacteria. Results Seventy-nine of the 100 samples were culture positive. One hundred twenty-seven organisms were isolated, and 29 different species were identified. Most microorganisms were Gram-positive bacteria (45 samples or 57.0% of all positive culture samples), whereas Gram-negative bacteria, anaerobic bacteria, and fungi were found in 39 (49.4%), 24 (30.4%), and four samples (5.1%), respectively. The most frequently isolated group was coagulase-negative staphylococci (27.8%), followed by nonspore-forming Gram-positive rods (anaerobe) (17.7%) and Pseudomonas aeruginosa (15.2%). Of the 100 samples, five, 45, and 50 samples were obtained from patients with acute dacryocystitis, chronic dacryocystitis, and simple epiphora, respectively. Subgroup analysis showed that Gram-negative organisms were isolated more frequently from the chronic dacryocystitis subgroup than from the simple epiphora subgroup (P=0.012). Antimicrobial susceptibility testing demonstrated that ciprofloxacin was the most effective drug against all Gram-positive and Gram-negative organisms. Conclusion Patients with PANDO, with or without clinical signs of lacrimal infection, were culture positive. Gram-negative organisms were frequently isolated, which were different from previous studies. Ciprofloxacin was the most effective agent against all Gram-positive and Gram-negative organisms. PMID:26955261

  17. Prevalence of Mycobacterium avium subspecies paratuberculosis and hepatitis E in New World camelids in Austria.

    PubMed

    Stanitznig, A; Khol, J L; Lambacher, B; Franz, S; Wittek, T; Kralik, P; Slana, I; Vasickova, P

    2017-07-07

    Mycobacterium avium subspecies paratuberculosis (MAP) is the causative agent of paratuberculosis in domestic ruminants and New World Camelids (NWC). Hepatitis E virus (HEV) is an important public health concern worldwide. The virus has been identified in several species, some of them serving as a reservoir for zoonotic HEV strains. Husbandry and breeding of llamas and alpacas have increased in Austria in recent years. Therefore, the aim of the present study was to evaluate the prevalence of MAP and HEV in NWC in Austria. Altogether 445 animals, originating from 78 farms were enrolled in the study. Of the animals sampled, 184 (41.35%) were llamas and 261 (58.65%) were alpacas. 443 blood samples for MAP-ELISA and 399 faecal samples for quantitative PCR (qPCR) and culture for MAP as well as for HEV detection by RT-qPCR have been collected. All of the 399 animals tested for shedding of MAP were negative by faecal solid culture. Using qPCR, 15 (3.8%) of the animals were MAP positive and 384 (96.2%) negative. Out of the 443 serum samples examined for specific antibodies against MAP by ELISA, 6 (1.4%) were positive, 1 (0.2%) was questionable and 436 (98.4%) samples were negative. All faecal samples were tested negative for HEV.

  18. Improving compound-protein interaction prediction by building up highly credible negative samples.

    PubMed

    Liu, Hui; Sun, Jianjiang; Guan, Jihong; Zheng, Jie; Zhou, Shuigeng

    2015-06-15

    Computational prediction of compound-protein interactions (CPIs) is of great importance for drug design and development, as genome-scale experimental validation of CPIs is not only time-consuming but also prohibitively expensive. With the availability of an increasing number of validated interactions, the performance of computational prediction approaches is severely impended by the lack of reliable negative CPI samples. A systematic method of screening reliable negative sample becomes critical to improving the performance of in silico prediction methods. This article aims at building up a set of highly credible negative samples of CPIs via an in silico screening method. As most existing computational models assume that similar compounds are likely to interact with similar target proteins and achieve remarkable performance, it is rational to identify potential negative samples based on the converse negative proposition that the proteins dissimilar to every known/predicted target of a compound are not much likely to be targeted by the compound and vice versa. We integrated various resources, including chemical structures, chemical expression profiles and side effects of compounds, amino acid sequences, protein-protein interaction network and functional annotations of proteins, into a systematic screening framework. We first tested the screened negative samples on six classical classifiers, and all these classifiers achieved remarkably higher performance on our negative samples than on randomly generated negative samples for both human and Caenorhabditis elegans. We then verified the negative samples on three existing prediction models, including bipartite local model, Gaussian kernel profile and Bayesian matrix factorization, and found that the performances of these models are also significantly improved on the screened negative samples. Moreover, we validated the screened negative samples on a drug bioactivity dataset. Finally, we derived two sets of new interactions by training an support vector machine classifier on the positive interactions annotated in DrugBank and our screened negative interactions. The screened negative samples and the predicted interactions provide the research community with a useful resource for identifying new drug targets and a helpful supplement to the current curated compound-protein databases. Supplementary files are available at: http://admis.fudan.edu.cn/negative-cpi/. © The Author 2015. Published by Oxford University Press.

  19. Significance of pregnancy test false negative results due to elevated levels of β-core fragment hCG.

    PubMed

    Johnson, Sarah; Eapen, Saji; Smith, Peter; Warren, Graham; Zinaman, Michael

    2017-01-01

    Very high levels of β-core fragment human chorionic gonadotrophin (βcf-hCG) are reported to potentially cause false negative results in point-of-care (POC)/over-the-counter (OTC) pregnancy tests. To investigate this further, women's daily early morning urine samples, collected prior to conception and during pregnancy, were analysed for intact, free β-, and βcf-hCG. The proportion of βcf-hCG was found to be related to that of hCG produced and in circulation. Therefore, best practice for accuracy testing of POC/OTC pregnancy tests would be to test devices against clinical samples containing high levels of βcf-hCG as well as standards spiked with biologically relevant ratios.

  20. Evaluation of the VIDAS Anti-HCV Assay for Detection of Hepatitis C Virus Infection.

    PubMed

    Hyun, Jungwon; Ko, Dae Hyun; Kang, Hee Jung; Whang, Dong Hee; Cha, Young Joo; Kim, Hyun Soo

    2016-11-01

    Anti-hepatitis C virus antibody (anti-HCV) assays are recommended for screening HCV-infected persons. The VIDAS Anti-HCV Assay (bioMérieux, France), based on the enzyme-linked fluorescence test principle, was recently introduced in Korea. We evaluated the clinical performance of the VIDAS assay. One hundred HCV-positive and 1,002 HCV-negative blood samples confirmed by Architect anti-HCV (Abbott Laboratories, USA) and COBAS TaqMan HCV real-time PCR (Roche Diagnostics, USA) or the Procleix Ultrio Plus Assay (Gen-Probe Incorporated, USA) were obtained from the Human Serum Bank (HSB) and tested by VIDAS. In case of discrepant results, we conducted a recombinant immunoblot assay (RIBA). The agreement rates for known HCV-positive and HCV-negative samples between the VIDAS assay and the HSB testing were 100% (95% confidence interval [CI]: 96.4-100%) and 99.5% (95% CI: 98.8-99.8%), respectively. One of the five discrepant samples was positive for Core 2+ and NS3-2 2+ reactivity, two samples were negative, and the other two were indeterminate regarding NS4 2+ reactivity in RIBA. We observed a significant but weak positive correlation between the titers of VIDAS and Architect assays (r=0.315, P<0.001). The VIDAS anti-HCV assay, developed on the VIDAS automated immunoassay platform based on the ready-to-use, single-sample test concept may be useful in small-to-medium-sized laboratories. It showed good agreement with Architect anti-HCV and COBAS PCR assays and is therefore useful for detection of HCV infection. Weakly test-positive (ambiguous) samples require additional testing by another anti-HCV, RIBA, or HCV RNA assay.

  1. Evaluation of the VIDAS Anti-HCV Assay for Detection of Hepatitis C Virus Infection

    PubMed Central

    Hyun, Jungwon; Ko, Dae-Hyun; Kang, Hee Jung; Whang, Dong Hee

    2016-01-01

    Background Anti-hepatitis C virus antibody (anti-HCV) assays are recommended for screening HCV-infected persons. The VIDAS Anti-HCV Assay (bioMérieux, France), based on the enzyme-linked fluorescence test principle, was recently introduced in Korea. We evaluated the clinical performance of the VIDAS assay. Methods One hundred HCV-positive and 1,002 HCV-negative blood samples confirmed by Architect anti-HCV (Abbott Laboratories, USA) and COBAS TaqMan HCV real-time PCR (Roche Diagnostics, USA) or the Procleix Ultrio Plus Assay (Gen-Probe Incorporated, USA) were obtained from the Human Serum Bank (HSB) and tested by VIDAS. In case of discrepant results, we conducted a recombinant immunoblot assay (RIBA). Results The agreement rates for known HCV-positive and HCV-negative samples between the VIDAS assay and the HSB testing were 100% (95% confidence interval [CI]: 96.4-100%) and 99.5% (95% CI: 98.8-99.8%), respectively. One of the five discrepant samples was positive for Core 2+ and NS3-2 2+ reactivity, two samples were negative, and the other two were indeterminate regarding NS4 2+ reactivity in RIBA. We observed a significant but weak positive correlation between the titers of VIDAS and Architect assays (r=0.315, P<0.001). Conclusions The VIDAS anti-HCV assay, developed on the VIDAS automated immunoassay platform based on the ready-to-use, single-sample test concept may be useful in small-to-medium-sized laboratories. It showed good agreement with Architect anti-HCV and COBAS PCR assays and is therefore useful for detection of HCV infection. Weakly test-positive (ambiguous) samples require additional testing by another anti-HCV, RIBA, or HCV RNA assay. PMID:27578508

  2. Decisions About Testing for HIV While in a Relationship: Perspectives From an Urban, Convenience Sample of HIV-Negative Male Couples Who Have a Sexual Agreement.

    PubMed

    Mitchell, Jason W; Lee, Ji-Young; Woodyatt, Cory; Bauermeister, José; Sullivan, Patrick; Stephenson, Rob

    2017-05-01

    Many HIV-negative male couples establish a sexual agreement to help manage their HIV risk; however, less is known about their decisions about testing in this context. The present study examined whether male couples discussed HIV testing and explored their decisions about testing in the context of their sexual agreement at the individual- and couple-levels. Qualitative dyadic interview data were collected from 29 HIV-negative male couples with a sexual agreement who resided in Atlanta or Detroit; the sample was stratified by agreement type. Content analysis revealed male couples' decisions about HIV testing as routine, self-assurance, reliance and assumption on partner, beginning of relationship testers, and/or trust; decisions varied between partners and by agreement type. Findings suggest prevention efforts should help male couples integrate HIV testing into their sexual agreement that matches their agreement type and associated HIV-related risk behavior, and help shift their one-sided decisions about testing to a couple's mutually shared decision.

  3. Laboratory audit as part of the quality assessment of a primary HPV-screening program.

    PubMed

    Hortlund, Maria; Sundström, Karin; Lamin, Helena; Hjerpe, Anders; Dillner, Joakim

    2016-02-01

    As primary HPV screening programs are rolled out, methods are needed for routine quality assurance of HPV laboratory analyzes. To explore the use of similar design for audit as currently used in cytology-based screening, to estimate the clinical sensitivity to identify women at risk for CIN 3 or worse (CIN3+). Population-based cohort study conducted within the cervical screening program in Stockholm, Sweden, in 2011-2012. All women with histopathologically confirmed CIN3+ in the following two years were identified by registry analysis. Primary HPV and cytology screening results were collected. For women who had not been HPV tested, biobanked cytology samples were HPV-tested. If the original HPV result had been negative, the sample and subsequent biopsies were analyzed with broad HPV typing (general primer PCR and Luminex). 154 women had a biobanked prediagnostic cytology sample taken up to 2 years before a histopathologically confirmed CIN3+. The high-risk HPV-positivity was 97% (148/154 women), whereas 143/154 (94%) women had had a cytological abnormality. Among the six HPV-negative samples, one sample was HPV 33 positive in repeat testing whereas the other five cases were HPV-negative also on repeat testing, but HPV-positive in the subsequent tumor tissue. A sensitivity of the HPV test that is higher than the sensitivity of cytology suggests adequate quality of the testing. Regular audits of clinical sensitivity, similar to those of cytology-based screening, should be used also in HPV-based screening programs, in order to continuously monitor the performance of the analyzes. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Accuracy of BRT and Delvotest microbial inhibition tests as affected by composition of ewe's milk.

    PubMed

    Althaus, Rafael; Torres, Antonio; Peris, Cristofol; Beltran, M Carmen; Fernandez, Nemesio; Molina, M Pilar

    2003-03-01

    The presence of drug residues in ewe's milk samples can be determined by microbial assays. The main limitation of these tests is the large number of false-positive results associated with them. False-positive results can be explained by the interaction of certain substances naturally existing in ewe's milk with the growth of the microorganism used in the test. In this study, milk chemical composition (fat, protein, lactose, total solids), somatic cell counts (SCCs), free fatty acid concentrations, and lactoperoxidase system components were determined in order to investigate their influence on the rate of false-positive results for the BRT and Delvotest microbiological inhibitor tests. Milk samples were obtained after morning milking of Manchega ewes at 15, 30, 45, 60, 75, 90, 105, 120, and 135 days after parturition. The animals did not receive any kind of treatment or medicated feed throughout the experiment. The false-positive rates for BRT and Delvotest were 3.75 and 2.4%, respectively. When the logistic regression model was applied, the percentages of total solids for positive samples were significantly different from those for negative samples (16.90 versus 18.42% for BRT, 16.05 versus 18.45% for Delvotest), while the SCC logarithmic transformation was significantly higher for the positive samples than for the negative samples (5.38 versus 5.11 log units for BRT, 5.32 versus 5.11 log units for Delvotest). Moreover, Delvotest-positive samples exhibited thiocyanate concentrations higher than those of Delvotest-negative samples (8.18 mg/liter versus 6.85 mg/liter). Further analyses are needed to confirm the possible presence of antimicrobial residues in this particular type of milk sample.

  5. Detection of antibodies against hepatitis A in blood spots dried on filter paper. Is this a reliable method for epidemiological studies?

    PubMed Central

    Gil, A.; González, A.; Dal-Ré, R.; Dominguez, V.; Astasio, P.; Aguilar, L.

    1997-01-01

    Diluted dried blood drops on filter paper were compared with serum samples as a specimen source for qualitative anti-HAV antibody determination by ELISA. A total of 298 serum samples and dried blood drops were collected from a population of healthy adolescents (15.3 +/- 1.2 years old). The prevalence of anti-HAV antibody obtained by testing serum samples was 7.7% (95% CI:4.8 10.1). Compared with serum sampling the sensitivity and specificity of diluted dried blood drops were 91.3 and 99.3%. The positive and negative predictive values were 91.3 and 99.3%, respectively, and the likelihood ratios of positive and negative results were 91 and 0.09. It is proposed that this test represents a reliable procedure for anti-HAV antibody testing. PMID:9129596

  6. Comparative evaluation of commercially available point-of-care heartworm antigen tests using well-characterized canine plasma samples.

    PubMed

    Starkey, Lindsay A; Bowles, Joy V; Payton, Mark E; Blagburn, Byron L

    2017-11-09

    Dirofilaria immitis is a worldwide parasite that is endemic in many parts of the United States. There are many commercial assays available for the detection of D. immitis antigen, one of which was modified and has reentered the market. Our objective was to compare the recently reintroduced Witness® Heartworm (HW) Antigen test Kit (Zoetis, Florham Park, NJ) and the SNAP® Heartworm RT (IDEXX Laboratories, Inc., Westbrook, ME) to the well-based ELISA DiroChek® Heartworm Antigen Test Kit (Zoetis, Florham Park, NJ). Canine plasma samples were either received at the Auburn Diagnostic Parasitology Laboratory from veterinarians submitting samples for additional heartworm testing (n = 100) from 2008 to 2016 or purchased from purpose-bred beagles (n = 50, presumed negative) in 2016. Samples were categorized as "positive," "borderline" or "negative" using our established spectrophotometric cutoff value with the DiroChek® assay when a sample was initially received and processed. Three commercially available heartworm antigen tests (DiroChek®, Witness® HW, and SNAP® RT) were utilized for simultaneous testing of the 150 samples in random order as per their package insert with the addition of spectrophotometric optical density (OD) readings of the DiroChek® assay. Any samples yielding discordant test results between assays were further evaluated by heat treatment of plasma and retesting. Chi-square tests for the equality of proportions were utilized for statistical analyses. Concordant results occurred in 140/150 (93.3%) samples. Discrepant results occurred in 10/150 samples tested (6.6%): 9/10 occurring in the borderline heartworm (HW) category and 1/10 occurring in the negative HW category. The sensitivity and specificity of each test compared to the DiroChek® read by spectrophotometer was similar to what has been reported previously (Witness®: sensitivity 97.0% [94.1-99.4%], specificity 96.4% [95.5-100.0%]; SNAP® RT: sensitivity 90.9% [78.0-100.0%], specificity 98.8% [96.0-100.0%]). There were significant differences detected when comparing the sensitivities of the SNAP® RT and the Witness® HW to the DiroChek® among the 150 total samples (p = 0.003) and the 50 "borderline" samples (p = 0.001). In this study, the sensitivity of the Witness® HW was higher than the sensitivity of the SNAP® RT when compared with the DiroChek® test results prior to heat treatment of samples.

  7. Voluntary counselling and testing for HIV in a Zambian mining community: serial interviews with people testing negative.

    PubMed

    Sikasote, Janet; Grant, Liz; Chinn, David J; Macwang'i, Mubiana; Murray, Scott A

    2011-08-01

    To understand the influence of voluntary counselling and testing (VCT) and an HIV-negative result on subsequent sexual behaviour; and to identify the specific felt needs of those testing negative. Serial interviews, 6 months apart, with people who had tested negative, and three one-off focus group discussions with counsellors. Interviews were transcribed verbatim and analysed thematically. Paired transcripts were analysed longitudinally. Purposively sampled from first attenders for VCT who had tested negative. Four health-facility affiliated VCT centres in two mining towns in the Copperbelt Province of Zambia. Participants in the 42 initial and 31 follow-up interviews understood VCT as 'testing for HIV'. Most participants reported having adopted safer sexual behaviour months before attending VCT. They had already recognised personal susceptibility to HIV infection and reported engaging both emotionally and cognitively with the issues of testing. Ultimately attendance at testing was to know their status in order to regain control of their lives. Unmet post-test support needs were common and included additional information, supportive networks, life-skills training and access to recreational activities. In this population who tested HIV negative the majority said they had made life changes months before attending VCT. Counselling served to consolidate pre-test decisions about risk behaviour. Those testing HIV negative are underserved compared with those testing positive. We recommend that counselling for HIV should be de-linked from testing to encourage earlier attendance for counselling and that clients testing negative should receive more post-test support to help them remain HIV negative.

  8. A two-year follow-up study of the PCV2 status of a Danish pig herd that was initially assumed to be PCV2-free.

    PubMed

    Kristensen, Charlotte S; Hjulsager, Charlotte K; Larsen, Lars E

    2015-01-01

    A longitudinal study was carried out to investigate whether a herd that had previously tested negative for porcine circovirus type 2 (PCV2) by polymerase chain reaction (PCR) was free of PCV2 or whether the negative profiles indicate that the level of PCV2 varies over time. In eight Danish herds that had initially tested negative for PCV2 by quantitative polymerase chain reaction (PCR), additional sampling was performed. Only one of the herds was still PCV2-negative in the additional sampling and was included in the study. The herd was a finishing herd, subclinically infected with PCV2, but vaccinated against PCV2 to improve performance. The herd was monitored by taking blood samples every seventh week over a period of two years and was not found to be continuously negative for PCV2 by PCR. The first time PCV2 was detected by PCR, in May 2010, PCV2 vaccination had been withdrawn from the herd, and at the same time the herd was infected with porcine reproductive and respiratory syndrome virus (PRRS). The PCV2-negative status, measured by PCR, was obtained in the first sampling after the PCV2 vaccination had been reintroduced. When PCV2 vaccination was withdrawn again in September 2011, the herd tested positive for PCV2 by PCR, and this time it continued to be PCV2-positive, even though PCV2 vaccination had been reintroduced. A Danish finishing herd that appeared to be PCV2-free from the start of a period of two years was not free of PCV2 during the entire period.

  9. Evaluation of three commercial rapid tests for detecting antibodies to human immunodeficiency virus.

    PubMed

    Ng, K P; Saw, T L; Baki, A; Kamarudin, R

    2003-08-01

    Determine HIV-1/2, Chembio HIV-1/2 STAT-PAK and PenTest are simple/rapid tests for the detection of antibodies to HIV-1 and HIV-2 in human whole blood, serum and plasma samples. The assay is one step and the result is read visually within 15 minutes. Using 92 known HIV-1 reactive sera and 108 known HIV-1 negative sera, the 3 HIV tests correctly identified all the known HIV-1 reactive and negative samples. The results indicated that Determine HIV-1/2, Chembio HIV-1/2 STAT-PAK and PenTest HIV are as sensitive and specific (100% concordance) as Microparticle Enzyme Immunoassay. The data indicated that these 3 HIV tests are effective testing systems for diagnosis of HIV infection in a situation when the conventional Enzyme Immunoassay is not suitable.

  10. PERFORMANCE EVALUATION OF A PROTOTYPE ARCHITECT ANTIBODY ASSAY FOR BABESIA MICROTI.

    PubMed

    Cheng, Kevin; Coller, Kelly E; Marohnic, Christopher C; Pfeiffer, Zachary A; Fino, James R; Elsing, Randee R; Bergsma, Janet; Marcinkus, Marilee A; Kar, Alak K; Gumbs, Orlando H; Otis, Kathy S; Fishpaugh, Jeffrey; Schultz, Phillip W; Pope, Mark R; Narvaez, Alfredo R; Wong, Susan J; Madison-Antenucci, Susan; Leary, Thomas P; Dawson, George J

    2018-05-09

    The tick-borne protozoan Babesia microti is responsible for more than 200 cases of transfusion-transmitted babesiosis (TTB) infection in the United States over the last 30 years. Measures to mitigate the risk of TTB include nucleic acid testing (NAT) and B. microti antibody testing. A fully automated prototype B. microti antibody test was developed on the ARCHITECT instrument. The specificity was determined to be 99.98% in volunteer blood donors (n=28,740) from areas considered as low endemic for B. microti The sensitivity of the prototype test was studied in experimentally-infected macaques; a total of 128 samples were detected compared to 125 with the indirect fluorescent antibody test (IFA), additionally, 83 (89.2%) of the PCR positive samples were detected compared to 81 (87.1%) using the IFA test. All PCR positive samples that tested negative in the prototype antibody test were pre-seroconversion period samples. Following seroconversion, periods of intermittent parasitemia occurred; 17 PCR negative samples drawn in-between PCR positive bleed dates, tested positive both by the prototype test (robust reactivity) and IFA (marginal reactivity) prior to the administration of therapeutic drugs, indicating that the PCR test failed to detect samples from persistently infected macaques. The prototype assay detected 56 of 58 (96.6%) human subjects diagnosed with clinical babesiosis by both PCR and IFA testing. Overall, the prototype anti-babesia assay provides a highly sensitive and specific test for the diagnosis of B. microti infection. While PCR is preferred for detection of window period parasitemia, antibody tests detect infected subjects during periods of low level parasitemia. Copyright © 2018 Cheng et al.

  11. False-negative BRAF V600E mutation results on fine-needle aspiration cytology of papillary thyroid carcinoma.

    PubMed

    Paek, Se Hyun; Kim, Byung Seup; Kang, Kyung Ho; Kim, Hee Sung

    2017-11-13

    The BRAF V600E mutation is highly specific for papillary thyroid carcinoma (PTC). A test for this mutation can increase the diagnostic accuracy of fine-needle aspiration cytology (FNAC), but a considerably high false-negative rate for the BRAF V600E mutation on FNAC has been reported. In this study, we investigated the risk factors associated with false-negative BRAF V600E mutation results on FNAC. BRAF V600E mutation results of 221 PTC nodules between December 2011 and June 2013 were retrospectively reviewed. BRAF V600E mutation results on both preoperative FNAC and postoperative formalin-fixed, paraffin-embedded (FFPE) samples were compared. We investigated the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of BRAF V600E mutation results on FNAC. And, we identified the risk factors associated with false-negative results. Of 221 PTC nodules, 150 (67.9%) on FNAC and 185 (83.7%) on FFPE samples were BRAF V600E mutation positive. The sensitivity, specificity, PPV, and NPV for BRAF V600E mutation testing with FNAC were 80.5, 97.2, 99.3, and 49.3%, respectively. Thirty-six (16.3%) BRAF V600E mutation-negative nodules on FNAC were mutation positive on FFPE sample analysis. Risk factors for these false-negative results were age, indeterminate FNAC results (nondiagnostic, atypia of undetermined significance (AUS), and findings suspicious for PTC), and PTC subtype. False-negative rate of BRAF mutation testing with FNAC for thyroid nodules is increased in cases of old age, indeterminate FNAC pathology results, and certain PTC subtypes. Therapeutic surgery can be considered for these cases. A well-designed prospective study with informed consent of patients will be essential for more informative results.

  12. Evaluation of two 4th generation point-of-care assays for the detection of Human Immunodeficiency Virus infection.

    PubMed

    Stafylis, Chrysovalantis; Klausner, Jeffrey D

    2017-01-01

    Fourth generation assays detect simultaneously antibodies for HIV and the p24 antigen, identifying HIV infection earlier than previous generation tests. Previous studies have shown that the Alere Determine HIV-1/2 Combo has lower than anticipated performance in detecting antibodies for HIV and the p24 antigen. Furthermore, there are currently very few studies evaluating the performance of Standard Diagnostics BIOLINE HIV Ag/Ab Combo. To evaluate the performance of the Alere Determine HIV-1/2 Combo and the Standard Diagnostics BIOLINE HIV Ag/Ab Combo in a panel of frozen serum samples. The testing panel included 133 previously frozen serum specimens from the UCLA Clinical Microbiology & Immunoserology laboratory. Reference testing included testing for HIV antibodies by a 3rd generation enzyme immunoassay followed by HIV RNA detection. Antibody negative and RNA positive sera were also tested by a laboratory 4th generation HIV Ab/Ag enzyme immunoassay. Reference testing yielded 97 positives for HIV infection and 36 negative samples. Sensitivity of the Alere test was 95% (88-98%), while the SD Bioline sensitivity was 91% (83-96%). Both assays showed 100% (90-100%) specificity. No indeterminate or invalid results were recorded. Among 13 samples with acute infection (HIV RNA positive, HIV antibody negative), 12 were found positive by the first assay and 8 by the second. The antigen component of the Alere assay detected 10 acute samples, while the SD Bioline assay detected only one. Both rapid assays showed very good overall performance in detecting HIV infection in frozen serum samples, but further improvements are required to improve the performance in acute infection.

  13. House Dust Mite Prevalence in the House of Patients with Atopic Dermatitis in Mashhad, Iran

    PubMed Central

    Ziyaei, Toktam; Berenji, Fariba; Jabbari-Azad, Farahzad; Fata, Abdolmajid; Jarahi, Lida; Fereidouni, Mohammad

    2017-01-01

    Background: Being exposed to house dust mites intensifies atopic dermatitis. This study has investigated the contamination rate with Dermatophagoides mites in patient’s residential home with atopic dermatitis. Methods: In this cross-sectional study, 40 patients took part with atopic dermatitis (positive or negative for mites by prick Dermal Test). Samples were collected from 3 locations (living room, bedroom and bed) by vacuum cleaner. Dust samples (transferred to freezer −20 °C) were examined by direct method and flotation. The data were analyzed using statistical SPSS vr.20 software. Results: Twenty patients of positive prick test included 8 (40%) male and 12 (60%) female. The results of direct observation of mites: 7 cases (35%) in bedding sheets, 6 cases (30%) bedrooms’ carpet, 3 cases (15%) living room’s carpet. Twenty patients of negative prick test included 8 (40%) male and 12 (60%) female. Only mites were found (5%) in living room’s carpets of negative prick test patients. Dermatophagoides pteronyssinus was more frequent than Dermatophagoides farinae. (98% vs 83%). Conclusion: Fifty-five percent of residential homes of prick test positive patients and only 5% of residential homes of prick test negative patients were positive for mite. Sunshine provided home had fewer mites than home where sunshine is not provided. Prick test positive patients used handmade carpets more than machine made ones. In positive prick test patients, mites were found in bed sheet and bedroom’s carpet more than negative prick test patient’s sheets and carpets. PMID:29062855

  14. Receiver-operating characteristic curves for somatic cell scores and California mastitis test in Valle del Belice dairy sheep.

    PubMed

    Riggio, Valentina; Pesce, Lorenzo L; Morreale, Salvatore; Portolano, Baldassare

    2013-06-01

    Using receiver-operating characteristic (ROC) curve methodology this study was designed to assess the diagnostic effectiveness of somatic cell count (SCC) and the California mastitis test (CMT) in Valle del Belice sheep, and to propose and evaluate threshold values for those tests that would optimally discriminate between healthy and infected udders. Milk samples (n=1357) were collected from 684 sheep in four flocks. The prevalence of infection, as determined by positive bacterial culture was 0.36, 87.7% of which were minor and 12.3% major pathogens. Of the culture negative samples, 83.7% had an SCC<500,000/mL and 97.4% had <1,000,000cells/mL. When the associations between SC score (SCS) and whole sample status (culture negative vs. infected), minor pathogen status (culture negative vs. infected with minor pathogens), major pathogen status (culture negative vs. infected with major pathogens), and CMT results were evaluated, the estimated area under the ROC curve was greater for glands infected with major compared to minor pathogens (0.88 vs. 0.73), whereas the area under the curve considering all pathogens was similar to the one for minor pathogens (0.75). The estimated optimal thresholds were 3.00 (CMT), 2.81 (SCS for the whole sample), 2.81 (SCS for minor pathogens), and 3.33 (SCS for major pathogens). These correctly classified, respectively, 69.0%, 73.5%, 72.6% and 91.0% of infected udders in the samples. The CMT appeared only to discriminate udders infected with major pathogens. In this population, SCS appeared to be the best indirect test of the bacteriological status of the udder. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Evaluation of an automated microplate technique in the Galileo system for ABO and Rh(D) blood grouping.

    PubMed

    Xu, Weiyi; Wan, Feng; Lou, Yufeng; Jin, Jiali; Mao, Weilin

    2014-01-01

    A number of automated devices for pretransfusion testing have recently become available. This study evaluated the Immucor Galileo System, a fully automated device based on the microplate hemagglutination technique for ABO/Rh (D) determinations. Routine ABO/Rh typing tests were performed on 13,045 samples using the Immucor automated instruments. Manual tube method was used to resolve ABO forward and reverse grouping discrepancies. D-negative test results were investigated and confirmed manually by the indirect antiglobulin test (IAT). The system rejected 70 tests for sample inadequacy. 87 samples were read as "No-type-determined" due to forward and reverse grouping discrepancies. 25 tests gave these results because of sample hemolysis. After further tests, we found 34 tests were caused by weakened RBC antibodies, 5 tests were attributable to weak A and/or B antigens, 4 tests were due to mixed-field reactions, and 8 tests had high titer cold agglutinin with blood qualifications which react only at temperatures below 34 degrees C. In the remaining 11 cases, irregular RBC antibodies were identified in 9 samples (seven anti-M and two anti-P) and two subgroups were identified in 2 samples (one A1 and one A2) by a reference laboratory. As for D typing, 2 weak D+ samples missed by automated systems gave negative results, but weak-positive reactions were observed in the IAT. The Immucor Galileo System is reliable and suited for ABO and D blood groups, some reasons may cause a discrepancy in ABO/D typing using a fully automated system. It is suggested that standardization of sample collection may improve the performance of the fully automated system.

  16. Sample size determination for a three-arm equivalence trial of Poisson and negative binomial responses.

    PubMed

    Chang, Yu-Wei; Tsong, Yi; Zhao, Zhigen

    2017-01-01

    Assessing equivalence or similarity has drawn much attention recently as many drug products have lost or will lose their patents in the next few years, especially certain best-selling biologics. To claim equivalence between the test treatment and the reference treatment when assay sensitivity is well established from historical data, one has to demonstrate both superiority of the test treatment over placebo and equivalence between the test treatment and the reference treatment. Thus, there is urgency for practitioners to derive a practical way to calculate sample size for a three-arm equivalence trial. The primary endpoints of a clinical trial may not always be continuous, but may be discrete. In this paper, the authors derive power function and discuss sample size requirement for a three-arm equivalence trial with Poisson and negative binomial clinical endpoints. In addition, the authors examine the effect of the dispersion parameter on the power and the sample size by varying its coefficient from small to large. In extensive numerical studies, the authors demonstrate that required sample size heavily depends on the dispersion parameter. Therefore, misusing a Poisson model for negative binomial data may easily lose power up to 20%, depending on the value of the dispersion parameter.

  17. Mild test anxiety influences neurocognitive performance among African Americans and European Americans: identifying interfering and facilitating sources.

    PubMed

    Thames, April D; Panos, Stella E; Arentoft, Alyssa; Byrd, Desiree A; Hinkin, Charles H; Arbid, Natalie

    2015-01-01

    The current study examined ethnic/racial differences in test-related anxiety and its relationship to neurocognitive performance in a community sample of African American (n = 40) and European American (n = 36) adults. The authors hypothesized the following: (a) Test-anxiety related to negative performance evaluation would be associated with lower neurocognitive performance, whereas anxiety unrelated to negative evaluation would be associated with higher neurocognitive performance. (b) African American participants would report higher levels of anxiety about negative performance evaluation than European Americans. (c) European Americans would report higher levels of anxiety unrelated to negative performance evaluation. The first two hypotheses were supported: Ethnic/racial differences in test-taking anxiety emerged such that African Americans reported significantly higher levels of negative performance evaluation, which was associated with lower cognitive performance. The third hypothesis was not supported: African Americans and European Americans reported similar levels of test-anxiety unrelated to negative evaluation. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  18. Usefulness of Two Aspergillus PCR Assays and Aspergillus Galactomannan and β-d-Glucan Testing of Bronchoalveolar Lavage Fluid for Diagnosis of Chronic Pulmonary Aspergillosis

    PubMed Central

    Urabe, Naohisa; Sano, Go; Suzuki, Junko; Hebisawa, Akira; Nakamura, Yasuhiko; Koyama, Kazuya; Ishii, Yoshikazu; Tateda, Kazuhiro; Homma, Sakae

    2017-01-01

    ABSTRACT We evaluated the usefulness of an Aspergillus galactomannan (GM) test, a β-d-glucan (βDG) test, and two different Aspergillus PCR assays of bronchoalveolar lavage fluid (BALF) samples for the diagnosis of chronic pulmonary aspergillosis (CPA). BALF samples from 30 patients with and 120 patients without CPA were collected. We calculated the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each test individually and in combination with other tests. The optical density index values, as determined by receiver operating characteristic analysis, for the diagnosis of CPA were 0.5 and 100 for GM and βDG testing of BALF, respectively. The sensitivity and specificity of the GM test, βDG test, and PCR assays 1 and 2 were 77.8% and 90.0%, 77.8% and 72.5%, 86.7% and 84.2%, and 66.7% and 94.2%, respectively. A comparison of the PCR assays showed that PCR assay 1 had a better sensitivity, a better negative predictive value, and a better negative likelihood ratio and PCR assay 2 had a better specificity, a better positive predictive value, and a better positive likelihood ratio. The combination of the GM and βDG tests had the highest diagnostic odds ratio. The combination of the GM and βDG tests on BALF was more useful than any single test for diagnosing CPA. PMID:28330887

  19. Clearance of Vancomycin-Resistant Enterococcus Concomitant With Administration of a Microbiota-Based Drug Targeted at Recurrent Clostridium difficile Infection.

    PubMed

    Dubberke, Erik R; Mullane, Kathleen M; Gerding, Dale N; Lee, Christine H; Louie, Thomas J; Guthertz, Harriet; Jones, Courtney

    2016-09-01

    Background.  Vancomycin-resistant Enterococcus (VRE) is a major healthcare-associated pathogen and a well known complication among transplant and immunocompromised patients. We report on stool VRE clearance in a post hoc analysis of the Phase 2 PUNCH CD study assessing a microbiota-based drug for recurrent Clostridium difficile infection (CDI). Methods.  A total of 34 patients enrolled in the PUNCH CD study received 1 or 2 doses of RBX2660 (microbiota suspension). Patients were requested to voluntarily submit stool samples at baseline and at 7, 30, and 60 days and 6 months after the last administration of RBX2660. Stool samples were tested for VRE using bile esculin azide agar with 6 µg/mL vancomycin and Gram staining. Vancomycin resistance was confirmed by Etest. Results.  VRE status (at least 1 test result) was available for 30 patients. All stool samples for 19 patients (63.3%, mean age 61.7 years, 68% female) tested VRE negative. Eleven patients (36.7%, mean age 75.5 years, 64% female) were VRE positive at the first test (baseline or 7-day follow-up). Of these patients, 72.7%, n = 8 converted to negative as of the last available follow-up (30 or 60 days or 6 months). Of the other 3: 1 died (follow-up data not available); 1 patient remained positive at all follow-ups; 1 patient retested positive at 6 months with negative tests during the interim. Conclusions.  Although based on a small sample size, this secondary analysis demonstrated the possibility of successfully converting a high percentage of VRE-positive patients to negative in a recurrent CDI population with RBX2660.

  20. Diagnosis of toxoplasmosis after allogeneic stem cell transplantation: results of DNA detection and serological techniques.

    PubMed

    Fricker-Hidalgo, Hélène; Bulabois, Claude-Eric; Brenier-Pinchart, Marie-Pierre; Hamidfar, Rebecca; Garban, Frédéric; Brion, Jean-Paul; Timsit, Jean-François; Cahn, Jean-Yves; Pelloux, Hervé

    2009-01-15

    The biological diagnosis of toxoplasmosis after allogeneic hematopoietic stem cell transplantation (HSCT) is based on the detection of Toxoplasma gondii DNA in blood specimens or other samples. Serological testing is used mainly to define the immunity status of the patient before HSCT. The aim of our study was to examine the performance of polymerase chain reaction (PCR) and serological techniques in the diagnosis of toxoplasmosis after HSCT. Seventy patients underwent allogeneic HSCT from September 2004 through September 2006. DNA was detected by PCR, and immunoglobulin G and immunoglobulin M were detected by enzyme-linked immunosorbent assay. The results of immunoglobulin G detection before allogeneic HSCT were positive in 40 (57.1%) of the patients and negative in 30 (42.9%). After HSCT, 57 patients (81.4%) had test results that were negative for immunoglobulin M and had negative results of DNA detection, without toxoplasmosis infection. Four patients (5.7%) had at least 4 samples with positive PCR results and/or test results positive for immunoglobulin M against T. gondii; toxoplasmosis was then confirmed by clinical symptoms. Nine patients (12.9%) with positive PCR results and 1 or 2 samples with test results negative for immunoglobulin M were considered to have asymptomatic T. gondii infection. Reactivation of latent infection was the cause of toxoplasmosis in 3 of the 4 patients, and toxoplasmosis occurred as a primary infection in 1 patient. The detection of specific anti-T. gondii immunoglobulin M was the only biological evidence of toxoplasmosis in 2 patients, and samples were positive for immunoglobulin M before PCR was performed in 1 patient. Thus, after HSCT, all patients were at risk for toxoplasmosis; all patients who receive HSCTs should be followed up with biological testing that combines PCR and serological techniques.

  1. Protein p16 as a marker of dysplastic and neoplastic alterations in cervical epithelial cells

    PubMed Central

    Volgareva, Galina; Zavalishina, Larisa; Andreeva, Yulia; Frank, Georgy; Krutikova, Ella; Golovina, Darya; Bliev, Alexander; Spitkovsky, Dimitry; Ermilova, Valeriya; Kisseljov, Fjodor

    2004-01-01

    Background Cervical carcinomas are second most frequent type of women cancer. Success in diagnostics of this disease is due to the use of Pap-test (cytological smear analysis). However Pap-test gives significant portion of both false-positive and false-negative conclusions. Amendments of the diagnostic procedure are desirable. Aetiological role of papillomaviruses in cervical cancer is established while the role of cellular gene alterations in the course of tumor progression is less clear. Several research groups including us have recently named the protein p16INK4a as a possible diagnostic marker of cervical cancer. To evaluate whether the specificity of p16INK4a expression in dysplastic and neoplastic cervical epithelium is sufficient for such application we undertook a broader immunochistochemical registration of this protein with a highly p16INK4a-specific monoclonal antibody. Methods Paraffin-embedded samples of diagnostic biopsies and surgical materials were used. Control group included vaginal smears of healthy women and biopsy samples from patients with cervical ectopia. We examined 197 samples in total. Monoclonal antibody E6H4 (MTM Laboratories, Germany) was used. Results In control samples we did not find any p16INK4a-positive cells. Overexpression of p16INK4a was detected in samples of cervical dysplasia (CINs) and carcinomas. The portion of p16INK4a-positive samples increased in the row: CIN I – CIN II – CIN III – invasive carcinoma. For all stages the samples were found to be heterogeneous with respect to p16INK4a-expression. Every third of CINs III and one invasive squamous cell carcinoma (out of 21 analyzed) were negative. Conclusions Overexpression of the protein p16INK4a is typical for dysplastic and neoplastic epithelium of cervix uteri. However p16INK4a-negative CINs and carcinomas do exist. All stages of CINs and carcinomas analyzed are heterogeneous with respect to p16INK4a expression. So p16INK4a-negativity is not a sufficient reason to exclude a patient from the high risk group. As far as normal cervical epithelium is p16INK4a-negative and the ratio p16INK4a-positive/ p16INK4a-negative samples increases at the advanced stages application of immunohisto-/cytochemical test for p16INK4a may be regarded as a supplementary test for early diagnostics of cervical cancer. PMID:15339339

  2. Laboratory and clinical evaluation of on-site urine drug testing.

    PubMed

    Beck, Olof; Carlsson, Sten; Tusic, Marinela; Olsson, Robert; Franzen, Lisa; Hulten, Peter

    2014-11-01

    Products for on-site urine drug testing offer the possibility to perform screening for drugs of abuse directly at the point-of-care. This is a well-established routine in emergency and dependency clinics but further evaluation of performance is needed due to inherent limitations with the available products. Urine drug testing by an on-site product was compared with routine laboratory methods. First, on-site testing was performed at the laboratory in addition to the routine method. Second, the on-site testing was performed at a dependency clinic and urine samples were subsequently sent to the laboratory for additional analytical investigation. The on-site testing products did not perform with assigned cut-off levels. The subjective reading between the presence of a spot (i.e. negative test result) being present or no spot (positive result) was difficult in 3.2% of the cases, and occurred for all parameters. The tests performed more accurately in drug negative samples (specificity 96%) but less accurately for detecting positives (sensitivity 79%). Of all incorrect results by the on-site test the proportion of false negatives was 42%. The overall agreement between on-site and laboratory testing was 95% in the laboratory study and 98% in the clinical study. Although a high degree of agreement was observed between on-site and routine laboratory urine drug testing, the performance of on-site testing was not acceptable due to significant number of false negative results. The limited sensitivity of on-site testing compared to laboratory testing reduces the applicability of these tests.

  3. ctDNA Determination of EGFR Mutation Status in European and Japanese Patients with Advanced NSCLC: The ASSESS Study.

    PubMed

    Reck, Martin; Hagiwara, Koichi; Han, Baohui; Tjulandin, Sergei; Grohé, Christian; Yokoi, Takashi; Morabito, Alessandro; Novello, Silvia; Arriola, Edurne; Molinier, Olivier; McCormack, Rose; Ratcliffe, Marianne; Normanno, Nicola

    2016-10-01

    To offer patients with EGFR mutation-positive advanced NSCLC appropriate EGFR tyrosine kinase inhibitor treatment, mutation testing of tumor samples is required. However, tissue/cytologic samples are not always available or evaluable. The large, noninterventional diagnostic ASSESS study (NCT01785888) evaluated the utility of circulating free tumor-derived DNA (ctDNA) from plasma for EGFR mutation testing. ASSESS was conducted in 56 centers (in Europe and Japan). Eligible patients (with newly diagnosed locally advanced/metastatic treatment-naive advanced NSCLC) provided diagnostic tissue/cytologic and plasma samples. DNA extracted from tissue/cytologic samples was subjected to EGFR mutation testing using local practices; designated laboratories performed DNA extraction/mutation testing of blood samples. The primary end point was level of concordance of EGFR mutation status between matched tissue/cytologic and plasma samples. Of 1311 patients enrolled, 1288 were eligible. Concordance of mutation status in 1162 matched samples was 89% (sensitivity 46%, specificity 97%, positive predictive value 78%, and negative predictive value 90%). A group of 25 patients with apparent false-positive plasma results was overrepresented for cytologic samples, use of less sensitive tissue testing methodologies, and smoking habits associated with high EGFR mutation frequency, indicative of false-negative tumor results. In cases in which plasma and tumor samples were tested with identical highly sensitive methods, positive predictive value/sensitivity were generally improved. These real-world data suggest that ctDNA is a feasible sample for EGFR mutation analysis. It is important to conduct mutation testing of both tumor and plasma samples in specialized laboratories, using robust/sensitive methods to ensure that patients receive appropriate treatments that target the molecular features of their disease. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  4. Validation of a hospital-laboratory workstation for immunohematologic methods.

    PubMed

    Schoenfeld, Helge; Pretzel, Karin J; von Heymann, Christian; Neuner, Bruno; Kalus, Ulrich; Kiesewetter, Holger; Pruss, Axel

    2010-01-01

    The FREELYS Nano system (Diagast) is a manual workstation for ABO/D grouping, Rh phenotyping, K typing, and antibody screening (ABS) for immunoglobulin G (IgG) antibodies only and works with the erythrocyte-magnetized technology (EMT). The principle of EMT is based on magnetization of red blood cells and avoids centrifugation and washing steps. A total of 304 samples were tested with our routine blood bank methods, 100 samples for ABO/D grouping, 196 samples (100 at first evaluation, 96 at second evaluation) for Rh phenotyping and K typing (PK7200, Olympus), and 108 samples for ABS (DiaMed). All samples were tested in parallel with the FREELYS Nano. We found a 100% concordance between the observed (FREELYS Nano) and the expected (Olympus PK7200) results for ABO/D grouping in all 100 samples. For Rh phenotyping and K tests, in 24 of 100 samples false-positive reactions were observed in the first evaluation by the FREELYS Nano. After changing the test kit batch for Rh phenotyping by the manufacturer, a complete concordance in Rh phenotyping and K tests was observed in a second evaluation. For ABS, the FREELYS Nano showed in 4 of 108 samples (3.7%) false-negative reactions for IgG antibodies (two anti-K, one anti-E, one anti-C(w)), and one (0.9%) false-positive reaction. The FREELYS Nano is reliably suited to ABO/D grouping, Rh phenotyping, and K testing. The rate of false-negative reactions for IgG antibodies should be reduced.

  5. Development of a qualitative indirect ELISA for the measurement of rabies virus-specific antibodies from vaccinated dogs and cats.

    PubMed

    Cliquet, F; McElhinney, L M; Servat, A; Boucher, J M; Lowings, J P; Goddard, T; Mansfield, K L; Fooks, A R

    2004-04-01

    A protocol suitable for the detection of rabies virus-specific antibodies in serum samples from companion animals using an enzyme linked immunosorbent assay (ELISA) is described. This method has been used successfully for the qualitative assessment of rabies virus-specific antibodies in serum samples from a cohort of vaccinated dogs and cats. In two initial field studies, a variable population of field samples from the Veterinary Laboratories Agency (VLA), United Kingdom were tested. In the first study (n = 1000), the number of false-positive and false-negative results was 11 samples (1.1%) and 67 samples (6.7%), respectively. In the second study (n = 920), the number of false-positive and false-negative results was 7 samples (0.8%) and 52 samples (5.7%). In a third study, undertaken at l'Agence Française de Sécurité Sanitaire des Aliments (AFSSA), Nancy, France (n = 440), 1 false-positive sample (0.23%) and 91 (20.7%) false-negative samples were identified. Data generated using this prototype ELISA indicate a strong correlation for specificity when compared to the gold standard fluorescent antibody virus neutralisation (FAVN) test. Although the ELISA has a lower sensitivity than the FAVN test, it is a useful tool for rapidly screening serum samples from vaccinated companion animals. Using a cut-off value of 0.6 EU/ml, the sensitivity (R = % from VLA and 79% from AFSSA) and specificity (R = 97.3%) indices between the ELISA compared favourably with data generated using the FAVN test. The major advantages of the ELISA test are that it is a qualitative tool that can be completed in four hours, does not require the use of live virus and can be performed without the need for specialised laboratory containment. This contrasts with 4 days using conventional rabies antibody virus neutralisation assays. Using the current format, the ELISA assay described would be a valuable screening tool for the detection of rabies antibodies from vaccinated domestic animals in combination with other Office International des Epizooties (OIE) accepted serological tests.

  6. The relationships between air exposure, negative pressure, and hemolysis.

    PubMed

    Pohlmann, Joshua R; Toomasian, John M; Hampton, Claire E; Cook, Keith E; Annich, Gail M; Bartlett, Robert H

    2009-01-01

    The purpose of this study was to describe the hemolytic effects of both negative pressure and an air-blood interface independently and in combination in an in vitro static blood model. Samples of fresh ovine or human blood (5 ml) were subjected to a bubbling air interface (0-100 ml/min) or negative pressure (0-600 mm Hg) separately, or in combination, for controlled periods of time and analyzed for hemolysis. Neither negative pressure nor an air interface alone increased hemolysis. However, when air and negative pressure were combined, hemolysis increased as a function of negative pressure, the air interface, and time. Moreover, when blood samples were exposed to air before initiating the test, hemolysis was four to five times greater than samples not preexposed to air. When these experiments were repeated using freshly drawn human blood, the same phenomena were observed, but the hemolysis was significantly higher than that observed in sheep blood. In this model, hemolysis is caused by combined air and negative pressure and is unrelated to either factor alone.

  7. Design and analysis of three-arm trials with negative binomially distributed endpoints.

    PubMed

    Mütze, Tobias; Munk, Axel; Friede, Tim

    2016-02-20

    A three-arm clinical trial design with an experimental treatment, an active control, and a placebo control, commonly referred to as the gold standard design, enables testing of non-inferiority or superiority of the experimental treatment compared with the active control. In this paper, we propose methods for designing and analyzing three-arm trials with negative binomially distributed endpoints. In particular, we develop a Wald-type test with a restricted maximum-likelihood variance estimator for testing non-inferiority or superiority. For this test, sample size and power formulas as well as optimal sample size allocations will be derived. The performance of the proposed test will be assessed in an extensive simulation study with regard to type I error rate, power, sample size, and sample size allocation. For the purpose of comparison, Wald-type statistics with a sample variance estimator and an unrestricted maximum-likelihood estimator are included in the simulation study. We found that the proposed Wald-type test with a restricted variance estimator performed well across the considered scenarios and is therefore recommended for application in clinical trials. The methods proposed are motivated and illustrated by a recent clinical trial in multiple sclerosis. The R package ThreeArmedTrials, which implements the methods discussed in this paper, is available on CRAN. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Diagnostic performance of influenza viruses and RSV rapid antigen detection tests in children in tertiary care.

    PubMed

    Moesker, F M; van Kampen, J J A; Aron, G; Schutten, M; van de Vijver, D A M C; Koopmans, M P G; Osterhaus, A D M E; Fraaij, P L A

    2016-06-01

    Rapid antigen detection tests (RADTs) are increasingly used to detect influenza viruses and respiratory syncytial virus (RSV). However, their sensitivity and specificity are a matter of debate, challenging their clinical usefulness. Comparing diagnostic performances of BinaxNow Influenza AB(®) (BNI) and BinaxNow RSV(®) (BNR), to those of real-time reverse transcriptase PCR (RT-PCR), virus isolation and direct immunofluorescence (D-IF) in paediatric patients. Between November 2005 and September 2013, 521 nasal washings from symptomatic children (age <5 years) attending our tertiary care centre were tested, with a combination of the respective assays using RT-PCR as gold standard. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of BNI were 69% (confidence interval [CI] [51-83]), 96% [94-97], 55% [39-70] and 98% [96-99] respectively. Of eleven false-negative samples, RT-PCR Ct-values were higher than all RT-PCR positive test results (27 vs 22, p=0.012). Of twenty false-positive samples, none were culture positive and two tested positive in D-IF. Sensitivity, specificity, PPV and NPV for BNR were 79% [73-85], 98% [96-99], 97% [93-99] and 88% [84-91]. Of the 42 false-negative samples the median Ct-value was higher than that of all RT-PCR positive samples (31 vs 23, p<0.0001). Five false-positive samples were detected. Three of these tested positive for RSV in virus isolation and D-IF. RADTs have a high specificity with BNR being superior to BNI. However, their relative low sensitivity limits their usefulness for clinical decision making in a tertiary care paediatric hospital. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Brief Report: Impact of Early Antiretroviral Therapy on the Performance of HIV Rapid Tests and HIV Incidence Assays.

    PubMed

    Fogel, Jessica M; Piwowar-Manning, Estelle; Debevec, Barbara; Walsky, Tamara; Schlusser, Katherine; Laeyendecker, Oliver; Wilson, Ethan A; McCauley, Marybeth; Gamble, Theresa; Tegha, Gerald; Soko, Dean; Kumwenda, Johnstone; Hosseinipour, Mina C; Chen, Ying Q; Cohen, Myron S; Eshleman, Susan H

    2017-08-01

    Antiretroviral therapy (ART) can downregulate antibody responses to HIV infection. We evaluated the impact of early vs. delayed ART on the performance of HIV diagnostic and incidence assays. Samples were obtained from 207 participants in the HPTN 052 trial, who were stably suppressed on ART for ≥4 years [Malawi sites; pre-ART CD4 cell count 350-550 cells/mm (early ART arm, N = 180) or <250 cells/mm or an AIDS-defining illness (delayed ART arm, N = 27)]. Samples were tested with 2 HIV rapid tests and 2 HIV incidence assays; selected samples were also tested with two fourth-generation immunoassays and a Western blot (WB) assay. A pre-ART sample was analyzed if the follow-up sample had a false-negative or weakly-reactive rapid test result, or had an incidence assay result indicative of recent infection (false-recent result). Ten (4.8%) samples had a nonreactive or weakly-reactive rapid test result (7/180 early ART arm, 3/27 delayed ART arm, P = 0.13); one sample had nonreactive fourth-generation assay results and 3 had indeterminate WBs. Forty (18.9%) samples had a false-recent incidence assay result; 16 (7.8%) had false-recent results with both incidence assays. Baseline samples had stronger rapid test and WB bands, higher fourth-generation assay signal-to-cutoff values, and fewer HIV incidence assay results indicative of recent infection. False-negative/weakly-reactive HIV rapid tests and false-recent HIV incidence assay results were observed in virally-suppressed individuals, regardless of pre-ART CD4 cell count. Downregulation of the antibody response to HIV infection in the setting of ART may impact population-level surveys of HIV prevalence and incidence.

  10. Clostridium difficile shows no trade-off between toxin and spore production within the human host.

    PubMed

    Blanco, Natalia; Walk, Seth; Malani, Anurag N; Rickard, Alexander; Benn, Michele; Eisenberg, Marisa; Zhang, Min; Foxman, Betsy

    2018-05-01

    This study aimed to describe the correlation between Clostridium difficile spore and toxin levels within the human host. In addition, we assessed whether overgrowth of Candida albicans modified this association. We measured toxin, spore and Candida albicans levels among 200 successively collected stool samples that tested positive for C. difficile, and PCR ribotyped these C. difficile isolates. Analysis of variance and linear regression were used to test the association between spore and toxin levels. Kruskal-Wallis tests and t-tests were used to compare the association between spore or toxin levels and host, specimen, or pathogen characteristics. C. difficile toxin and spore levels were positively associated (P<0.001); this association did not vary significantly with C. albicans overgrowth [≥5 logs of C. albicans colony-forming units (c.f.u.) g -1 ]. However, ribotypes 027 and 078-126 were significantly associated with higher levels of toxin and spores, and C. albicans overgrowth. The strong positive association observed between in vivo levels of C. difficile toxin and spores suggests that patients with more severe C. difficile infections may have increased spore production, enhancing C. difficile transmission. Although, on average, spore levels were higher in toxin-positive samples than in toxin-negative/PCR-positive samples, spores were found in almost all toxin-negative samples. The ubiquity of spore production among toxin-negative and formed stool samples emphasizes the importance of following infection prevention and control measures for all C. difficile-positive patients during their entire hospital stay.

  11. Self-criticism, dependency, and stress reactivity: an experience sampling approach to testing Blatt and Zuroff's (1992) theory of personality predispositions to depression in high-risk youth.

    PubMed

    Adams, Philippe; Abela, John R Z; Auerbach, Randy; Skitch, Steven

    2009-11-01

    S. J. Blatt and D. C. Zuroff's 1992 theory of personality predispositions to depression posits that individuals who possess high levels of self-criticism and/or dependency are vulnerable to developing depression following negative events. The current study used experience sampling methodology to test this theory in a sample of 49 children ages 7 to 14. Children completed measures of dependency, self-criticism, and depressive symptoms. Subsequently, children were given a handheld computer that signaled them to complete measures of depressive symptoms and negative events at randomly selected times over 2 months. Results of hierarchical linear modeling analyses indicated that higher levels of both self-criticism and dependency were associated with greater elevations in depressive symptoms following negative events. Furthermore, each personality predisposition remained a significant predictor of such elevations after controlling for the interaction between the other personality predisposition and negative events. The results suggest that dependency and self-criticism represent distinct vulnerability factors to depression in youth.

  12. Chikungunya virus RNA and antibody testing at a National Reference Laboratory since the emergence of Chikungunya virus in the Americas.

    PubMed

    Prince, Harry E; Seaton, Brent L; Matud, Jose L; Batterman, Hollis J

    2015-03-01

    Since first reported in the Americas in December 2013, chikungunya virus (CHIKV) infections have been documented in travelers returning from the Caribbean, with many cases identified by CHIKV antibody and/or RNA testing at our laboratory. We used our large data set to characterize the relationship between antibody titers and RNA detection and to estimate IgM persistence. CHIKV RNA was measured by nucleic acid amplification and CHIKV IgG/IgM by indirect immunofluorescence. Of the 1,306 samples submitted for RNA testing in January through September 2014, 393 (30%) were positive; for 166 RNA-positive samples, CHIKV antibody testing was also ordered, and 84% were antibody negative. Of the 6,971 sera submitted for antibody testing in January through September 2014, 1,811 (26%) were IgM positive; 1,461 IgM positives (81%) were also IgG positive. The relationship between the CHIKV antibody titers and RNA detection was evaluated using 376 IgM-positive samples (138 with RNA testing ordered and 238 deidentified and tested for RNA). RNA detection showed no significant association with the IgM titer but was inversely related to the IgG titer; 63% of the IgG negative sera were RNA positive, compared to 36% of sera with low IgG titers (1:10 to 1:80) and 16% with IgG titers of ≥1:160. Using second-sample results from 62 seroconverters, we estimated that CHIKV IgM persists for 110 days (95% confidence interval, 78 to 150 days) after the initial antibody-negative sample. These findings indicate that (i) RNA detection is more sensitive than antibody detection early in CHIKV infection, (ii) in the absence of RNA results, the IgG titer of the IgM-positive samples may be a useful surrogate for viremia, and (iii) CHIKV IgM persists for approximately 4 months after symptom onset. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  13. Credit WCT. Original 21/4"x21/4" color negative is housed in the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit WCT. Original 2-1/4"x2-1/4" color negative is housed in the JPL Photography Laboratory, Pasadena, California. At one time, Building 4285/E-86 accommodated tensile testing of propellant samples. This view shows a tensile strength tester set up for propellant tests, under the supervision of JPL staff member Milton Clay (JPL negative no. JPL-10291AC, 27 January 1989) - Jet Propulsion Laboratory Edwards Facility, Casting & Curing Building, Edwards Air Force Base, Boron, Kern County, CA

  14. Evaluation of Legionella real-time PCR against traditional culture for routine and public health testing of water samples.

    PubMed

    Collins, S; Stevenson, D; Walker, J; Bennett, A

    2017-06-01

    To evaluate the usefulness of Legionella qPCR alongside traditional culture for enumeration of Legionella from water samples as part of both routine and public health investigation testing. Routine water samples (n = 2002) and samples from public health investigations (n = 215) were analysed by culture and qPCR for Legionella spp., Legionella pneumophila and L. pneumophila sg-1. A negative qPCR result was highly predictive of a negative culture result for all water systems (negative predictive values, NPV from 97·4 to 100%). Positive predictive values (PPV) were lower (0-50%). Results for qPCR were generally larger than culture with average log 10 differences of 1·1 for Legionella spp. and 1·2 for L. pneumophila. Alert and action levels of 1000 and 10 000 GU per litre, respectively, are proposed for Legionella qPCR for hot and cold water systems (HCWS). The use of qPCR significantly reduced the time to results for public health investigations by rapidly identifying potential sources and ruling out others, thus enabling a more rapid and efficient response. The high NPV of qPCR supports its use to rapidly screen out negative samples without culture. Alert and action levels for Legionella qPCR for HCWS are proposed. Quantitative PCR will be a valuable tool for both routine and public health testing. This study generated comparative data of >2000 water samples by qPCR and culture. Action and alert levels have been recommended that could enable duty holders to interpret qPCR results to facilitate timely Legionella control and public health protection. © 2017 Crown copyright. Journal of Applied Microbiology © 2017 The Society for Applied Microbiology.

  15. Evaluation of the equivocal test results of Treponema pallidum haemagglutination assay.

    PubMed Central

    Su, S J; Huang, S; Chung, C Y; Yang, H M; Chow, Y O

    1990-01-01

    Two hundred and eighty Rapid Plasma Reagin (RPR) positive sera with an emphasis on cases with negative and borderline positive Treponema pallidum haemagglutination assay (TPHA) results were selected. Modified TPHA (M-TPHA) and fluorescent treponemal antibody absorption (FTA-abs) tests were used for comparison. One hundred and twenty five samples were TPHA negative, of which 78 and 69 cases were also negative by M-TPHA and FTA-abs, respectively. Eighty one sera negative by TPHA at a titre of 1/80 and positive at 1/40, considered to be negative according to the manufacturer's instructions, were also negative by M-TPHA (n = 11) and by FTA-abs (n = 1). Fifty borderline positive TPHA specimens gave one negative result by both M-TPHA and FTA-abs. The remaining 24 sera were positive by all three tests. Because of the high percentage of TPHA negative results among the positive RPR sera which became reactive when rechecked by the FTA-abs, it is concluded that as a confirmatory test the TPHA should be used not instead of but in addition to the FTA-abs. PMID:2180985

  16. Study of positive and negative feedback sensitivity in psychosis using the Wisconsin Card Sorting Test.

    PubMed

    Farreny, Aida; Del Rey-Mejías, Ángel; Escartin, Gemma; Usall, Judith; Tous, Núria; Haro, Josep Maria; Ochoa, Susana

    2016-07-01

    Schizophrenia involves marked motivational and learning deficits that may reflect abnormalities in reward processing. The purpose of this study was to examine positive and negative feedback sensitivity in schizophrenia using computational modeling derived from the Wisconsin Card Sorting Test (WCST). We also aimed to explore feedback sensitivity in a sample with bipolar disorder. Eighty-three individuals with schizophrenia and 27 with bipolar disorder were included. Demographic, clinical and cognitive outcomes, together with the WCST, were considered in both samples. Computational modeling was performed using the R syntax to calculate 3 parameters based on trial-by-trial execution on the WCST: reward sensitivity (R), punishment sensitivity (P), and choice consistency (D). The associations between outcome variables and the parameters were investigated. Positive and negative sensitivity showed deficits, but P parameter was clearly diminished in schizophrenia. Cognitive variables, age, and symptoms were associated with R, P, and D parameters in schizophrenia. The sample with bipolar disorder would show cognitive deficits and feedback abnormalities to a lesser extent than individuals with schizophrenia. Negative feedback sensitivity demonstrated greater deficit in both samples. Idiosyncratic cognitive requirements in the WCST might introduce confusion when supposing model-free reinforcement learning. Negative symptoms of schizophrenia were related to lower feedback sensitivity and less goal-directed patterns of choice. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. [Examination about utility of a Streptococcus pneumoniae capsular antigen swiftness search kit urine in a pneumonia patient].

    PubMed

    Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi

    2005-01-01

    We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.

  18. Evaluation of a new in-clinic test system to detect feline immunodeficiency virus and feline leukemia virus infection.

    PubMed

    Sand, Christina; Englert, Theresa; Egberink, Herman; Lutz, Hans; Hartmann, Katrin

    2010-06-01

    Many in-house tests for the diagnosis of feline immunodeficiency virus (FIV) and feline leukemia virus (FeLV) infection are licensed for use in veterinary practice. A new test with unknown performance has recently appeared on the market. The aims of this study were to define the efficacy of a new in-clinic test system, the Anigen Rapid FIV Ab/FeLV Ag Test, and to compare it with the current leading in-clinic test, the SNAP Kombi Plus FeLV Antigen/FIB Antibody Test. Three-hundred serum samples from randomly selected healthy and diseased cats presented to the Clinic of Small Animal Medicine at Ludwig Maximilian University were tested using both the Anigen Rapid Test and the SNAP Kombi Plus Test. Diagnostic sensitivity, specificity, and positive and negative predictive values were calculated for both tests using Western blot as the gold standard for verification of FIV infection and PCR as the gold standard for FeLV infection. The presence of antibodies against FIV was confirmed by Western blot in 9/300 samples (prevalence 3%). FeLV DNA was detected by PCR in 15/300 samples (prevalence 5%). For FIV infection the Anigen Rapid Test had a sensitivity of 88.9%, specificity of 99.7%, positive predictive value of 88.9%, and negative predictive value of 99.7%. For FeLV infection, the Anigen Rapid Test had a sensitivity of 40.0%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 96.9%. Diagnostic accuracy was similar to that of the SNAP Kombi Plus Test. The new Anigen Rapid FIV Ab/FeLV Ag Test performed very well and can be recommended for use in veterinary practice.

  19. Indeterminate RIBA results were associated with the absence of hepatitis C virus RNA (HCV-RNA) in blood donors.

    PubMed

    Pereira, Felicidade Mota; Zarife, Maria Alice Sant'ana; Reis, Eliana Almeida Gomes; G Reis, Mitermayer

    2014-01-01

    Hepatitis C virus (HCV) infection is diagnosed by the presence of antibodies and is supplemented by confirmatory testing methods, such as recombinant immunoblot assay (RIBA) and HCV-RNA detection. This study aimed to evaluate the efficacy of RIBA testing to diagnose HCV infection in blood donors positive for anti-HCV antibodies. A total of 102 subjects positive for anti-HCV determined by enzyme-linked immunosorbent assay (ELISA) at the Hematology and Hemotherapy Foundation of Bahia (HEMOBA) were later assessed with new samples using the Abbott Architect anti-HCV test (Abbott Diagnostics, Wiesbaden, Germany), the RIBA III test (Chiron RIBA HCV 3.0 SIA, Chiron Corp., Emeryville, CA, USA), the polymerase chain reaction (PCR; COBAS® AMPLICOR HCV Roche Diagnostics Corp., Indianapolis, IN, USA) and line probe assay (LiPA - Siemens, Tarrytown, NY, USA) genotyping for HCV diagnosis. Of these new samples, 38.2% (39/102) were positive, 57.8% (59/102) were negative and 3.9% (4/102) were indeterminate for anti-HCV; HCV-RNA was detected in 22.5% (23/102) of the samples. RIBA results were positive in 58.1% (25/43), negative in 9.3% (4/43) and indeterminate in 32.6% (14/43) of the samples. The prevailing genotypes were 1 (78.3%, 18/23), 3 (17.4%, 4/23) and 2 (4.3%, 1/23). All 14 samples with indeterminate RIBA results had undetectable viral loads (detection limit ≤50 IU/mL). Of these samples, 71.4% (10/14) were reevaluated six months later. Eighty percent (8/10) of these samples remained indeterminate by RIBA, and 20% (2/10) were negative. In this study, individuals with indeterminate RIBA results had no detectable HCV-RNA.

  20. An intradermal skin test for determination of immunity to varicella

    PubMed Central

    Somekh, E; Bujanover, Y; Tal, G; Dalal, I; Tanay, A; Lehman, D

    2001-01-01

    AIMS—To evaluate the usefulness of a diluted, inactivated solution of attenuated varicella vaccine in predicting susceptibility to varicella and its correlation with specific antibody titre to varicella.
METHODS—In a prospective blinded study, 63 healthy subjects (aged 2-43 years) were studied. Skin test solution was prepared from vials of OKA strain virus which was inactivated by exposure of the vials to room temperature for 10 days; solution was diluted at 1/50 with normal saline and kept at 4°C until used for skin testing. The material was injected intradermally. Serum samples were drawn prior to skin testing and kept at −70°C until analysis for antibody assay by the indirect fluorescent antibody (IFA) method.
RESULTS—Forty three patients were IFA antibody positive; 41 of them reacted to the skin test. One of the 20 IFA negative patients reacted to the skin test. Sixteen patients had two serological tests performed, one month apart. Four out of these 16 patients tested negative with the skin test. All four had negative serology on both samples. Six of the 12 IFA positive patients showed a boost in the antibody titre one month after application of the skin test. The specificity and sensitivity of the skin test compared to the IFA assay were both 95%, and the positive and negative predictive values were 97% and 90% respectively.
CONCLUSIONS—Results suggest that a varicella skin test prepared using this simple and relatively cheap method is a safe, sensitive, and specific tool by which to assess immunity to varicella.

 PMID:11719333

  1. Negative affect mediates the relationship between interpersonal problems and binge-eating disorder symptoms and psychopathology in a clinical sample: a test of the interpersonal model.

    PubMed

    Ivanova, Iryna V; Tasca, Giorgio A; Hammond, Nicole; Balfour, Louise; Ritchie, Kerri; Koszycki, Diana; Bissada, Hany

    2015-03-01

    This study evaluated the validity of the interpersonal model of binge-eating disorder (BED) psychopathology in a clinical sample of women with BED. Data from a cross-sectional sample of 255 women with BED were examined for the direct effects of interpersonal problems on BED symptoms and psychopathology, and indirect effects mediated by negative affect. Structural equation modelling analyses demonstrated that higher levels of interpersonal problems were associated with greater negative affect, and greater negative affect was associated with higher frequency of BED symptoms and psychopathology. There was a significant indirect effect of interpersonal problems on BED symptoms and psychopathology mediated through negative affect. Interpersonal problems may lead to greater BED symptoms and psychopathology, and this relationship may be partially explained by elevated negative affect. The results of the study are the first to provide support for the interpersonal model of BED symptoms and psychopathology in a clinical sample of women. Copyright © 2015 John Wiley & Sons, Ltd and Eating Disorders Association.

  2. Urine Cytology

    MedlinePlus

    ... types of cells were found in your urine sample. You may need to repeat the test. Negative. This means no cancer cells were identified in your urine sample. Atypical. This indicates that some abnormalities were found ...

  3. The diagnostic significance of lactate dehydrogenase isoenzymes in urinary cytology.

    PubMed Central

    Nishikawa, A.; Tanaka, T.; Takeuchi, T.; Fujihiro, S.; Mori, H.

    1991-01-01

    Lactate dehydrogenase (LDH) isoenzyme distribution was examined in 106 urine samples being tested cytologically for evidence of bladder cancer; the samples were selected to have less than 20 leucocytes and erythrocytes per high power field and the LDH pattern determined by electrophoresis. The Papanicolaou stained-smears showed 68 negative, 17 suspicious and 21 positive. The LDH M-fraction of the urinary supernatant in cytologically positive cases was significantly greater than in negative cases, although the latter included a few false negative samples. Some of the false negatives gave positive results for the LDH M-fraction; these results suggest that the determination of LDH isoenzymes in the urine is useful in diagnosing urinary tract cancers, including early stage, and for follow-up of patients with bladder cancers after surgical resection. PMID:2039708

  4. Evaluation of GeneXpert MTB/RIF for detection of Mycobacterium tuberculosis complex and rpo B gene in respiratory and non-respiratory clinical specimens at a tertiary care teaching hospital in Saudi Arabia.

    PubMed

    Somily, Ali M; Barry, Mazin A; Habib, Hanan A; Alotaibi, Fawzia E; Al-Zamil, Fahad A; Khan, Mohammed A; Sarwar, Mohammed S; Bakhash, Nawab D; Alrabiaah, Abdulkarim A; Shakoor, Zahid A; Senok, Abiola C

    2016-12-01

    To assess the performance of Xpert MTB/RIF, an automated molecular test for Mycobacterium tuberculosis (MTB) and resistance to rifampin (RIF), against smear microscopy and culture method for diagnosis of MTB infection. Methods: This is a retrospective analysis of 103 respiratory and 137 non-respiratory patient specimens suspected of tuberculosis at King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia performed between April 2014 and March 2015. Each sample underwent smear microscopy, mycobacterial culture, and GeneXpert MTB/RIF test. Results: Fifteen out of 103 respiratory samples were smear and culture positive, whereas 9 out of 137 non-respiratory samples were smear positive. Out of 9 smear positive specimens, 8 were also culture positive. All 15 culture positive respiratory samples were detected by Xpert MTB/RIF (sensitivity  and positive predictive value [PPV]=100%). Similarly, all 8 culture positive non-respiratory specimens were identified by Xpert MTB/RIF (sensitivity 100%; PPV 88.8%). The Xpert MTB/RIF detected only one false positive result in 88 smear negative respiratory specimens (specificity 98.9%; negative predictive value [NPV]= 100%). All 125 smear negative non-respiratory specimens tested negative by culture and Xpert MTB/RIF (sensitivity, specificity, PPV, NPV= 100%). Conclusion: The performance of Xpert MTB/RIF was comparable to the gold standard culture method for identification of MTB in both respiratory and non-respiratory clinical specimens.

  5. Evaluation of GeneXpert MTB/RIF for detection of Mycobacterium tuberculosis complex and rpo B gene in respiratory and non-respiratory clinical specimens at a tertiary care teaching hospital in Saudi Arabia

    PubMed Central

    Somily, Ali M.; Barry, Mazin A.; Habib, Hanan A.; Alotaibi, Fawzia E.; Al-Zamil, Fahad A.; Khan, Mohammed A.; Sarwar, Mohammed S.; Bakhash, Nawab D.; Alrabiaah, Abdulkarim A.; Shakoor, Zahid A.; Senok, Abiola C.

    2016-01-01

    Objectives To assess the performance of Xpert MTB/RIF, an automated molecular test for Mycobacterium tuberculosis (MTB) and resistance to rifampin (RIF), against smear microscopy and culture method for diagnosis of MTB infection. Methods This is a retrospective analysis of 103 respiratory and 137 non-respiratory patient specimens suspected of tuberculosis at King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia performed between April 2014 and March 2015. Each sample underwent smear microscopy, mycobacterial culture, and GeneXpert MTB/RIF test. Results Fifteen out of 103 respiratory samples were smear and culture positive, whereas 9 out of 137 non-respiratory samples were smear positive. Out of 9 smear positive specimens, 8 were also culture positive. All 15 culture positive respiratory samples were detected by Xpert MTB/RIF (sensitivity and positive predictive value [PPV]=100%). Similarly, all 8 culture positive non-respiratory specimens were identified by Xpert MTB/RIF (sensitivity 100%; PPV 88.8%). The Xpert MTB/RIF detected only one false positive result in 88 smear negative respiratory specimens (specificity 98.9%; negative predictive value [NPV]= 100%). All 125 smear negative non-respiratory specimens tested negative by culture and Xpert MTB/RIF (sensitivity, specificity, PPV, NPV= 100%). Conclusion The performance of Xpert MTB/RIF was comparable to the gold standard culture method for identification of MTB in both respiratory and non-respiratory clinical specimens. PMID:27874159

  6. Molecular Evidence of Malaria and Zoonotic Diseases Among Rapid Diagnostic Test-Negative Febrile Patients in Low-Transmission Season, Mali.

    PubMed

    Touré, Mahamoudou; Petersen, Pelle T; Bathily, Sidy N'd; Sanogo, Daouda; Wang, Christian W; Schiøler, Karin L; Konradsen, Flemming; Doumbia, Seydou; Alifrangis, Michael

    2017-02-08

    From November to December 2012 in Sélingué-Mali, blood samples from 88 febrile patients who tested negative by malaria Paracheck ® rapid diagnostic tests (RDTs) were used to assess the presence of sub-RDT Plasmodium falciparum as well as Borrelia , Coxiella burnetii , and Babesia applying molecular tools. Plasmodium sp. was present among 57 (60.2%) of the 88 malaria RDT-negative patients, whereas the prevalence of Borrelia , C. burnetii , and Babesia were 3.4% ( N = 3), 1.1% ( N = 1), and 0.0%, respectively. The additional diagnostic use of polymerase chain reaction (PCR) identified a high proportion of Plasmodium sp.-positive samples and although this may be a concern for malaria control, the respective PCR-identified malaria infections were less likely responsible for the observed fevers given the low parasite density. Also, the low infection levels of Borrelia and C. burnetii and lack of Babesia among the febrile patients call for further studies to assess the causes of fever among malaria RDT-negative patients in Sélingué. © The American Society of Tropical Medicine and Hygiene.

  7. Comparison of Simplexa universal direct PCR with cytotoxicity assay for diagnosis of Clostridium difficile infection: performance, cost, and correlation with disease.

    PubMed

    Landry, Marie L; Ferguson, David; Topal, Jeffrey

    2014-01-01

    Simplexa Clostridium difficile universal direct PCR, a real-time PCR assay for the detection of the C. difficile toxin B (tcdB) gene using the 3M integrated cycler, was compared with a two-step algorithm which includes the C. Diff Chek-60 glutamate dehydrogenase (GDH) antigen assay followed by cytotoxin neutralization. Three hundred forty-two liquid or semisolid stools submitted for diagnostic C. difficile testing, 171 GDH antigen positive and 171 GDH antigen negative, were selected for the study. All samples were tested by the C. Diff Chek-60 GDH antigen assay, cytotoxin neutralization, and Simplexa direct PCR. Of 171 GDH-positive samples, 4 were excluded (from patients on therapy or from whom duplicate samples were obtained) and 88 were determined to be true positives for toxigenic C. difficile. Of the 88, 67 (76.1%) were positive by the two-step method and 86 (97.7%) were positive by PCR. Seventy-nine were positive by the GDH antigen assay only. Of 171 GDH antigen-negative samples, none were positive by PCR. One antigen-negative sample positive by the cytotoxin assay only was deemed a false positive based on chart review. Simplexa C. difficile universal direct PCR was significantly more sensitive for detecting toxigenic C. difficile bacteria than cytotoxin neutralization (P = 0.0002). However, most PCR-positive/cytotoxin-negative patients did not have clear C. difficile disease. The estimated cost avoidance provided by a more rapid molecular diagnosis was outweighed by the cost of isolating and treating PCR-positive/cytotoxin-negative patients. The costs, clinical consequences, and impact on nosocomial transmission of treating and/or isolating patients positive for toxigenic C. difficile by PCR but negative for in vivo toxin production merit further study.

  8. Usefulness of Two Aspergillus PCR Assays and Aspergillus Galactomannan and β-d-Glucan Testing of Bronchoalveolar Lavage Fluid for Diagnosis of Chronic Pulmonary Aspergillosis.

    PubMed

    Urabe, Naohisa; Sakamoto, Susumu; Sano, Go; Suzuki, Junko; Hebisawa, Akira; Nakamura, Yasuhiko; Koyama, Kazuya; Ishii, Yoshikazu; Tateda, Kazuhiro; Homma, Sakae

    2017-06-01

    We evaluated the usefulness of an Aspergillus galactomannan (GM) test, a β-d-glucan (βDG) test, and two different Aspergillus PCR assays of bronchoalveolar lavage fluid (BALF) samples for the diagnosis of chronic pulmonary aspergillosis (CPA). BALF samples from 30 patients with and 120 patients without CPA were collected. We calculated the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each test individually and in combination with other tests. The optical density index values, as determined by receiver operating characteristic analysis, for the diagnosis of CPA were 0.5 and 100 for GM and βDG testing of BALF, respectively. The sensitivity and specificity of the GM test, βDG test, and PCR assays 1 and 2 were 77.8% and 90.0%, 77.8% and 72.5%, 86.7% and 84.2%, and 66.7% and 94.2%, respectively. A comparison of the PCR assays showed that PCR assay 1 had a better sensitivity, a better negative predictive value, and a better negative likelihood ratio and PCR assay 2 had a better specificity, a better positive predictive value, and a better positive likelihood ratio. The combination of the GM and βDG tests had the highest diagnostic odds ratio. The combination of the GM and βDG tests on BALF was more useful than any single test for diagnosing CPA. Copyright © 2017 American Society for Microbiology.

  9. [Evaluation of cytomegalovirus quantification in blood by the R-gene real-time PCR test].

    PubMed

    Marque-Juillet, S; Touzard, A; Monnier, S; Fernand-Laurent, C; Therby, A; Rigaudeau, S; Harzic, M

    2010-04-01

    Diagnosing the presence of cytomegalovirus (CMV) in the blood of immunodepressed patients is often done by quantitative polymerase chain reaction (Q-PCR) even though the reference method remains the antigenemia pp65 (Ag-pp65) test. To define the predictive value of the Q-PCR in the diagnosis of CMV disease and assess treatment efficacy using the CMV R-gene test. To compare the Q-PCR results and feasibility with those of the Ag-pp65 test. The Q-PCR was performed in 34 whole blood samples (frozen at -80 degrees C until use) from five patients diagnosed with CMV disease, defined as the presence of clinical signs and Ag-pp65 in the nuclei of more than two cells. After extraction, viral DNA was quantified in each sample using the Q-PCR CMV R-gene kit according to the manufacturer's instructions. Immediately after blood was drawn, the Ag-pp65 test had been performed in 32 samples using CINAkit (Argene). The 16 samples positive by the Ag-pp65 test were also positive by PCR; six samples negative by the Ag-pp65 test were positive by PCR; and the remaining 10 samples were negative by both techniques. During treatment, the two markers' kinetics were similar. The CMV R-gene test has a predictive value as good as that of the Ag-pp65 test but is fast and easier to use. A prospective study with a greater number of patients is needed to define the prediction threshold for CMV disease. Copyright 2009 Elsevier Masson SAS. All rights reserved.

  10. Limited value of testing for intrinsic factor antibodies with negative gastric parietal cell antibodies in pernicious anaemia.

    PubMed

    Khan, S; Del-Duca, C; Fenton, E; Holding, S; Hirst, J; Doré, P C; Sewell, W A C

    2009-05-01

    The appropriate testing strategy for diagnosing pernicious anaemia using gastric parietal cell (GPC) and/or intrinsic factor antibodies (IFA) is controversial. Intrinsic factor antibodies are found in only about 70% of cases. Indirect immunofluorescence screening for gastric parietal cell antibodies is more sensitive, labour intensive, and less specific. The frequency of antibody positivity (IFA and/or GPC) was retrospectively examined in patients tested for both autoantibodies over a three-year period. It was investigated whether B12 levels were related to antibody status. These findings were validated in a prospective study of IFA in 91 GPC negative patients with low B12 levels. Of 847 samples identified in the retrospective study, 4 (0.47%) were positive for only intrinsic factor antibodies, 731 (86.3%) positive for GPC alone, and 112 (13.2%) for both. Student t test on log-transformed data showed B12 levels had no bearing on autoantibody status. 91 consecutive patients with low B12 levels were tested for both autoantibodies; all were negative for gastric parietal cell antibodies. Only one sample was positive for intrinsic factor antibody using the porcine intrinsic factor assay, but was negative by a human recombinant intrinsic factor-based ELISA. This study provides evidence that testing for gastric parietal cell antibodies is an appropriate screening test for pernicious anaemia, with intrinsic factor antibodies reserved for confirmatory testing or in patients with other autoantibodies that mask the GPC pattern; B12 levels are not related to autoantibody status.

  11. HIV-negative partnered men's attitudes toward using an in-home rapid HIV test and associated factors among a sample of US HIV-Negative and HIV-discordant male couples.

    PubMed

    Mitchell, Jason W; Sullivan, Patrick S

    2015-03-01

    Many men who have sex with men acquire HIV while in a same-sex relationship. Studies with gay male couples have demonstrated that relationship characteristics and testing behaviors are important to examine for HIV prevention. Recently, an in-home rapid HIV test (HT) has become available for purchase in the United States. However, HIV-negative partnered men's attitudes toward using an HT and whether characteristics of their relationship affect their use of HTs remain largely unknown. This information is relevant for the development of HIV prevention interventions targeting at-risk HIV-negative and HIV-discordant male couples. To assess HIV-negative partnered men's attitudes and associated factors toward using an HT, a cross-sectional Internet-based survey was used to collect dyadic data from a national sample of 275 HIV-negative and 58 HIV-discordant gay male couples. Multivariate multilevel modeling was used to identify behavioral and relationship factors associated with 631 HIV-negative partnered men's attitudes toward using an HT. HIV-negative partnered men were "very likely" to use an HT. More positive attitudes toward using an HT were associated with being in a relationship of mixed or nonwhite race and with one or both men recently having had sex with a casual male partner. Less positive attitudes toward using an HT were associated with both partners being well educated, with greater resources (investment size) in the relationship, and with one or both men having a primary care provider. These findings may be used to help improve testing rates via promotion of HTs among gay male couples.

  12. The Unique Effects of Parental Alcohol and Affective Disorders, Parenting, and Parental Negative Affect on Adolescent Maladjustment

    ERIC Educational Resources Information Center

    Haller, Moira; Chassin, Laurie

    2011-01-01

    Using a high-risk community sample, multiple regression analyses were conducted separately for mothers (n = 416) and fathers (n = 346) to test the unique, prospective influence of parental negative affect on adolescent maladjustment (internalizing symptoms, externalizing symptoms, and negative emotionality) 2 years later over and above parental…

  13. Heterophile antibody interference in qualitative urine/serum hCG devices: Case report.

    PubMed

    Patel, Khushbu K; Gronowski, Ann M

    2016-06-01

    This case report investigates the origin of a false positive result on a serum qualitative human chorionic gonadotropin (hCG) device. A 46-year-old woman diagnosed with chronic myeloid leukemia presented with nausea and vomiting. A qualitative serum hCG test was interpreted as positive; however, a quantitative serum hCG test was negative (<5IU/L). To further investigate this discrepancy, the sample was pretreated with heterophilic blocking reagent (HBR). Additionally, the sample was tested on other qualitative hCG devices composed of antibodies from different animal sources. Blocking reagent from an automated quantitative immunoassay was also tested for its ability to inhibit the heterophile antibody interference. The qualitative test result was negative after pretreatment with heterophilic blocking reagent. Other devices composed of antibodies from different animal sources also demonstrated mixed results with the patient's sample. Blocking reagent obtained from the automated quantitative assay inhibited the heterophile antibody interference in the patient's sample. This case demonstrates that positive serum point-of-care hCG results should be interpreted with caution and confirmed with a quantitative serum hCG immunoassay when clinical suspicion is raised. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. Increased detection of smear-negative pulmonary tuberculosis by GeneXpert MTB/RIF® assay after bleach concentration.

    PubMed

    Tadesse, Mulualem; Aragaw, Dossegnaw; Rigouts, Leen; Abebe, Gemeda

    2016-06-01

    The GeneXpert MTB/RIF assay (Xpert) was endorsed as the initial diagnostic tool in people suspected of human immunodeficiency virus-associated or drug-resistant tuberculosis (TB). However, information regarding the performance of Xpert for diagnosing smear-negative TB in high burden settings remains limited. We evaluated the diagnostic accuracy of Xpert and the impact of bleach concentration on the performance of Xpert using smear-negative sputum samples from human immunodeficiency virus-negative patients. One spot and one morning smear-negative sputum samples per patient were examined using Xpert and culture at the Mycobacteriology Research Center of Jimma University, Ethiopia. The sputum culture on both Löwenstein-Jensen and/or Mycobacteria Growth Indicator Tube was the gold-standard. Of 185 smear-negative presumptive pulmonary TB cases, 19 (10.3%) had culture-proven TB. The sensitivity of Xpert on spot and morning sputum was similar (63.2%). Testing two specimens per patient insignificantly increased the sensitivity of Xpert. Bleach concentration and pelleting improved the sensitivity of Xpert over unprocessed sputum in paired samples (73.8% vs. 63.2%) without affecting the specificity (95%). Bleach concentration and pelleting allowed an additional seven cases of TB (missed on the first and second direct Xperts) to be detected, five of which were from culture-negative cases. Testing of a single sputum sample by Xpert can reach reasonable sensitivity and results would be available on the same day, avoiding loss of patients and treatment delay. The sensitivity of Xpert was improved after bleach concentration and pelleting, although its added value needs further study on a larger scale. Copyright © 2016 Asian-African Society for Mycobacteriology. Published by Elsevier Ltd. All rights reserved.

  15. Workplace drug testing in Italy: findings about second-stage testing.

    PubMed

    Vignali, Claudia; Stramesi, Cristiana; Morini, Luca; San Bartolomeo, Paolo; Groppi, Angelo

    2015-03-01

    Workplace Drug Testing (WDT) in Italy includes two levels of monitoring: a first stage concerning drug testing on urine samples and a second involving both urine and hair analysis. The second stage is performed only on workers who tested positive at the first level. We analyzed urine and hair specimens from 120 workers undergoing second-level testing between 2009 and 2012. Eighty percent of them had tested positive for cannabinoids during the first level analysis, and 15.8% for cocaine. Both urine and hair samples were analyzed in order to find the following drugs of abuse: amphetamines, buprenorphine, cannabinoids, cocaine, ecstasy, methadone, and opiates. Urine analyses were performed by immunological screening (EMIT); urine confirmatory tests and hair analyses were performed by gas chromatography-mass spectrometry (GC-MS). As regards second-stage testing on urine samples, 71.2% of workers were always negative, whereas 23.9% tested positive at least once for cannabinoids and 2.5% for cocaine. Hair analyses produced surprising results: 61.9% of hair samples tested negative, only 6.2% tested positive for cannabinoids, whereas 28.8% tested positive for cocaine. These findings confirm that second-level surveillance of WDT, which includes hair analysis, is very effective because it highlights drug intake - sometimes heavy - that cannot be revealed only through urine analyses. The employees for whom drug addiction is proved can begin rehabilitation, while keeping their job. Eventually, our results confirmed the widespread and undeclared use of cocaine in Italy. Copyright © 2014 John Wiley & Sons, Ltd.

  16. Accuracy and precision of Legionella isolation by US laboratories in the ELITE program pilot study.

    PubMed

    Lucas, Claressa E; Taylor, Thomas H; Fields, Barry S

    2011-10-01

    A pilot study for the Environmental Legionella Isolation Techniques Evaluation (ELITE) Program, a proficiency testing scheme for US laboratories that culture Legionella from environmental samples, was conducted September 1, 2008 through March 31, 2009. Participants (n=20) processed panels consisting of six sample types: pure and mixed positive, pure and mixed negative, pure and mixed variable. The majority (93%) of all samples (n=286) were correctly characterized, with 88.5% of samples positive for Legionella and 100% of negative samples identified correctly. Variable samples were incorrectly identified as negative in 36.9% of reports. For all samples reported positive (n=128), participants underestimated the cfu/ml by a mean of 1.25 logs with standard deviation of 0.78 logs, standard error of 0.07 logs, and a range of 3.57 logs compared to the CDC re-test value. Centering results around the interlaboratory mean yielded a standard deviation of 0.65 logs, standard error of 0.06 logs, and a range of 3.22 logs. Sampling protocol, treatment regimen, culture procedure, and laboratory experience did not significantly affect the accuracy or precision of reported concentrations. Qualitative and quantitative results from the ELITE pilot study were similar to reports from a corresponding proficiency testing scheme available in the European Union, indicating these results are probably valid for most environmental laboratories worldwide. The large enumeration error observed suggests that the need for remediation of a water system should not be determined solely by the concentration of Legionella observed in a sample since that value is likely to underestimate the true level of contamination. Published by Elsevier Ltd.

  17. ISOLATION AND IDENTIFICATION OF BRUCELLA SUIS IN PIGS AS ZOONOTIC DISEASE IN ENDEMIC AREAS OF EAST JAVA, INDONESIA.

    PubMed

    S, Emy Koestanti; Misaco, Wiwik; Chusniati, Sri; Maslachah, Lilik

    2018-01-01

    Brucellosis in pigs at East Java Indonesia has not only cause great economic losses due to a decrease in productivity of livestock but also are zoonotic. Infection on free brucelosis pigs were initially begun with the infected pigs both male and female, or the use of superior male pigs together. The elimination of the disease either on a group or population is considered as the most effective way to prevent the spread of the disease in pigs. Prevention efforts mainly addressed to vaccination, sanitary maintenace and government policy. The purpose of this study was to isolated and identified Brucella suis as the causative agent. The survey area were the pig farm owned by breeder farmers in the area of East Java Indonesia, at Kediri, Malang, Blitar and Probolinggo district. Blood samples obtained were tested with RBT. Pigs are suspected of being infected with Brucella if the RBT was positive that characterized with agglutination in the test results. If RBT was positive, bacteriological examination will be performed, with samples of visceral foetus organ, ie liver, spleen, placenta and amniotic fluid. Isolation and identification of Brucella suis were used Brucella Broth and Brucella Agar, and if the bacteri growthwill be continued with biochemical test ie H2S, urease, citrate, catalase and oxidase test. The positive results of Brucella suis showed positive urease, catalase andoxidase, but negative for citrate and H2S. RBT and bacteriolgical examination showed that 1 sample was positive Brucella suis , and 19 negative. The positive results showed positive urease, catalase and oxidase, but negative for citrate and H2S. Based on RBT test and bacteriological examination, there was 1 positive sample of brucellla suis, that is sample coming from Kediri district.

  18. ISOLATION AND IDENTIFICATION OF BRUCELLA SUIS IN PIGS AS ZOONOTIC DISEASE IN ENDEMIC AREAS OF EAST JAVA, INDONESIA

    PubMed Central

    S, Emy Koestanti; Misaco, Wiwik; Chusniati, Sri; Maslachah, Lilik

    2018-01-01

    Background: Brucellosis in pigs at East Java Indonesia has not only cause great economic losses due to a decrease in productivity of livestock but also are zoonotic. Infection on free brucelosis pigs were initially begun with the infected pigs both male and female, or the use of superior male pigs together. The elimination of the disease either on a group or population is considered as the most effective way to prevent the spread of the disease in pigs. Prevention efforts mainly addressed to vaccination, sanitary maintenace and government policy. The purpose of this study was to isolated and identified Brucella suis as the causative agent. Material and Methods: The survey area were the pig farm owned by breeder farmers in the area of East Java Indonesia, at Kediri, Malang, Blitar and Probolinggo district. Blood samples obtained were tested with RBT. Pigs are suspected of being infected with Brucella if the RBT was positive that characterized with agglutination in the test results. If RBT was positive, bacteriological examination will be performed, with samples of visceral foetus organ, ie liver, spleen, placenta and amniotic fluid. Isolation and identification of Brucella suis were used Brucella Broth and Brucella Agar, and if the bacteri growthwill be continued with biochemical test ie H2S, urease, citrate, catalase and oxidase test. The positive results of Brucella suis showed positive urease, catalase andoxidase, but negative for citrate and H2S. Results: RBT and bacteriolgical examination showed that 1 sample was positive Brucella suis, and 19 negative. The positive results showed positive urease, catalase and oxidase, but negative for citrate and H2S. Conclusion: Based on RBT test and bacteriological examination, there was 1 positive sample of brucellla suis, that is sample coming from Kediri district. PMID:29619446

  19. Evaluation of genotype MTBDRplus VER 2.0 line probe assay for the detection of MDR-TB in smear positive and negative sputum samples.

    PubMed

    Meaza, Abyot; Kebede, Abebaw; Yaregal, Zelalem; Dagne, Zekarias; Moga, Shewki; Yenew, Bazezew; Diriba, Getu; Molalign, Helina; Tadesse, Mengistu; Adisse, Desalegn; Getahun, Muluwork; Desta, Kassu

    2017-04-17

    Multi drug resistant tuberculosis (MDR-TB) poses formidable challenges to TB control due to its complex diagnostic and treatment challenges and often associated with a high rate of mortality. Accurate and rapid detection of MDR-TB is critical for timely initiation of treatment. Line Probe Assay (LPA) is a qualitative in vitro diagnostic test based on DNA-STRIP technology for the identification of the M. tuberculosis complex and its resistance to rifampicin (RMP) and/or isoniazid (INH). Hain Lifescience, GmbH, Germany has improved the sensitivity of Genotype MTBDRplus VER 2.0 LPA for the detection of MDR-TB; with the possibility of applying the tool in smear negative sputum samples. A cross sectional study was conducted on 274 presumptive MDR-TB patients referred to the National TB Reference Laboratory (NTRL), Ethiopian Public Health Institute (EPHI) who submitted sputum samples for laboratory diagnosis of drug resistant-TB testing. Seventy-two smear and culture positive samples processed in smear positive direct LPA category and 197 smear negative sputum samples were processed for direct LPA. Among the smear negative samples 145 (73.6%) were culture negative and 26 (13.2%) were culture positive. All specimens were processed using NALC-NaOH method and ZN smear microscopy done from sediments. Genotype MTBDRplus VER 2.0 done from processed sputum sediments and the result was compared against the reference, BACTEC MGIT 960 culture and DST. Sensitivity, specificity, PPV and NPV of Genotype MTBDRplus VER 2.0 assay was determined and P-value <0.05 was considered as statistically significant. The sensitivity, specificity, PPV and NPV of Genotype MTBDRplus VER 2.0 LPA were 96.4, 100, 100 and 96.9%, respectively for the detection of MDR-TB from direct smear positive sputum samples. The sensitivity, specificity, PPV and NPV of Genotype MTBDR plus VER 2.0 LPA were 77.8, 97.2, 82.4 and 97.2%, respectively, for the detection of M. tuberculosis from direct smear negative sputum samples. Fourteen (53.8%) samples had valid results with LPA among the 26 smear negative culture positive samples. The remaining 8 (30.8%) and 4 (15.4%) were invalid and negative with LPA, respectively. The sensitivity and specificity of Genotype MTBDRplus VER 2.0 LPA were 100% for the detection of MDR-TB among 14 direct smear negative and culture positive sputum samples. The most common mutations associated with RMP and INH resistance were S531L and S315TL, respectively. A single rare mutation (C15T/A16G) was detected for INH resistance. The diagnostic performance of Genotype MTBDRplus VER 2.0 LPA in direct smear positive sputum sample was highly sensitive and specific for early detection of MDR-TB. However, the diagnostic performance of this molecular assay in direct smear negative sputum sample was low and showed a high level of invalid results for detection of M. tuberculosis and its resistance to RMP and/or INH so it is unlikely to implement Genotype MTBDRplus VER 2.0 for the detection of MDR-TB in direct smear negative sample in our routine settings. The sensitivity of the assay should be improved for detection of MDR-TB in direct smear negative sputum specimens.

  20. The New Xpert MTB/RIF Ultra: Improving Detection of Mycobacterium tuberculosis and Resistance to Rifampin in an Assay Suitable for Point-of-Care Testing.

    PubMed

    Chakravorty, Soumitesh; Simmons, Ann Marie; Rowneki, Mazhgan; Parmar, Heta; Cao, Yuan; Ryan, Jamie; Banada, Padmapriya P; Deshpande, Srinidhi; Shenai, Shubhada; Gall, Alexander; Glass, Jennifer; Krieswirth, Barry; Schumacher, Samuel G; Nabeta, Pamela; Tukvadze, Nestani; Rodrigues, Camilla; Skrahina, Alena; Tagliani, Elisa; Cirillo, Daniela M; Davidow, Amy; Denkinger, Claudia M; Persing, David; Kwiatkowski, Robert; Jones, Martin; Alland, David

    2017-08-29

    The Xpert MTB/RIF assay (Xpert) is a rapid test for tuberculosis (TB) and rifampin resistance (RIF-R) suitable for point-of-care testing. However, it has decreased sensitivity in smear-negative sputum, and false identification of RIF-R occasionally occurs. We developed the Xpert MTB/RIF Ultra assay (Ultra) to improve performance. Ultra and Xpert limits of detection (LOD), dynamic ranges, and RIF-R rpoB mutation detection were tested on Mycobacterium tuberculosis DNA or sputum samples spiked with known numbers of M. tuberculosis H37Rv or Mycobacterium bovis BCG CFU. Frozen and prospectively collected clinical samples from patients suspected of having TB, with and without culture-confirmed TB, were also tested. For M. tuberculosis H37Rv, the LOD was 15.6 CFU/ml of sputum for Ultra versus 112.6 CFU/ml of sputum for Xpert, and for M. bovis BCG, it was 143.4 CFU/ml of sputum for Ultra versus 344 CFU/ml of sputum for Xpert. Ultra resulted in no false-positive RIF-R specimens, while Xpert resulted in two false-positive RIF-R specimens. All RIF-R-associated M. tuberculosis rpoB mutations tested were identified by Ultra. Testing on clinical sputum samples, Ultra versus Xpert, resulted in an overall sensitivity of 87.5% (95% confidence interval [CI], 82.1, 91.7) versus 81.0% (95% CI, 74.9, 86.2) and a sensitivity on sputum smear-negative samples of 78.9% (95% CI, 70.0, 86.1) versus 66.1% (95% CI, 56.4, 74.9). Both tests had a specificity of 98.7% (95% CI, 93.0, 100), and both had comparable accuracies for detection of RIF-R in these samples. Ultra should significantly improve TB detection, especially in patients with paucibacillary disease, and may provide more-reliable RIF-R detection. IMPORTANCE The Xpert MTB/RIF assay (Xpert), the first point-of-care assay for tuberculosis (TB), was endorsed by the World Health Organization in December 2010. Since then, 23 million Xpert tests have been procured in 130 countries. Although Xpert showed high overall sensitivity and specificity with pulmonary samples, its sensitivity has been lower with smear-negative pulmonary samples and extrapulmonary samples. In addition, the prediction of rifampin resistance (RIF-R) in paucibacillary samples and for a few rpoB mutations has resulted in both false-positive and false-negative results. The present study is the first demonstration of the design features and operational characteristics of an improved Xpert Ultra assay. This study also shows that the Ultra format overcomes many of the known shortcomings of Xpert. The new assay should significantly improve TB detection, especially in patients with paucibacillary disease, and provide more-reliable detection of RIF-R. Copyright © 2017 Chakravorty et al.

  1. An in-house assay for BK polyomavirus quantification using the Abbott m2000 RealTime system.

    PubMed

    Muldrew, Kenneth L; Lovett, Jennie L

    2013-11-01

    BK polyomavirus (BKPyV) quantification is useful for monitoring renal transplant patient response to therapy. The Abbott m2000 RealTime System employed by some clinical laboratories to perform US Food and Drug Administration-approved assays can also be used to develop in-house assays such as the one presented here. This study aimed to validate an in-house quantitative real-time PCR assay targeting the BKPyV major capsid VP1 gene for assessment of viral load using the Abbott m2000 RealTime System. BKPyV load was measured in 95 urine and plasma samples previously tested for BKPyV by one of three laboratories (46 BKPyV-positive samples consisting of 35 plasma and 11 urine samples; 49 samples negative for BKPyV consisting of 47 plasma and two urine samples). Two additional plasma specimens from the College of American Pathologists proficiency testing survey were also analysed. Precision studies were performed by diluting a high-viral-titre patient sample into BKPyV-negative pooled plasma to create high-positive (6.16 log10 copies ml(-1)) and low-positive (3.16 log10 copies ml(-1)) samples. For precision studies of inter-assay variability, a high-positive (7.0 log10 copies ml(-1)) and a low-positive (3.0 log10 copies ml(-1)) sample were measured in 20 separate runs. The assay's limit of quantification and limit of detection were 2.70 and 2.25 log10 copies ml(-1), respectively. The assay was linear from 2.70 to 9.26 log10 copies ml(-1). Of the 48 known positives, 43 were detected as positive, with three reported by the reference laboratory as values lower than the limit of detection. Two known positives at 3.27 and 3.80 log10 copies ml(-1) tested negative by the m2000 BKPyV assay. Of the 49 known negative samples, 48 were negative by the m2000 BKPyV load assay, with one sample confirmed positive by a reference laboratory. Qualitative analysis prior to discrepancy testing demonstrated a sensitivity of 89.58 % and a specificity of 97.96 %. Precision studies demonstrated inter-assay coefficients of variation of 0.63 % (high positive) and 4.38 % (low positive). Genotyping was performed on 22 patient samples, of which 21 (95.45 %) were type I and one (4.55 %) was type II. In conclusion, the m2000 BKPyV viral load assay sensitivity, specificity, linear range, precision and cost effectiveness make it an attractive methodology for clinical laboratories using the Abbott m2000 RealTime System.

  2. Reliability of rapid diagnostic tests in diagnosing pregnancy-associated malaria in north-eastern Tanzania

    PubMed Central

    2012-01-01

    Background Accurate diagnosis and prompt treatment of pregnancy-associated malaria (PAM) are key aspects in averting adverse pregnancy outcomes. Microscopy is the gold standard in malaria diagnosis, but it has limited detection and availability. When used appropriately, rapid diagnostic tests (RDTs) could be an ideal diagnostic complement to microscopy, due to their ease of use and adequate sensitivity in detecting even sub-microscopic infections. Polymerase chain reaction (PCR) is even more sensitive, but it is mainly used for research purposes. The accuracy and reliability of RDTs in diagnosing PAM was evaluated using microscopy and PCR. Methods A cohort of pregnant women in north-eastern Tanzania was followed throughout pregnancy for detection of plasmodial infection using venous and placental blood samples evaluated by histidine rich protein 2 (HRP-2) and parasite lactate dehydrogenase (pLDH) based RDTs (Parascreen™) or HRP-2 only (Paracheck Pf® and ParaHIT®f), microscopy and nested Plasmodium species diagnostic PCR. Results From a cohort of 924 pregnant women who completed the follow up, complete RDT and microscopy data was available for 5,555 blood samples and of these 442 samples were analysed by PCR. Of the 5,555 blood samples, 49 ((proportion and 95% confidence interval) 0.9% [0.7 -1.1]) samples were positive by microscopy and 91 (1.6% [1.3-2.0]) by RDT. Forty-six (50.5% [40.5 - 60.6]) and 45 (49.5% [39.4 – 59.5]) of the RDT positive samples were positive and negative by microscopy, respectively, whereas nineteen (42.2% [29.0 - 56.7]) of the microscopy negative, but RDT positive, samples were positive by PCR. Three (0.05% [0.02 - 0.2]) samples were positive by microscopy but negative by RDT. 351 of the 5,461 samples negative by both RDT and microscopy were tested by PCR and found negative. There was no statistically significant difference between the performances of the different RDTs. Conclusions Microscopy underestimated the real burden of malaria during pregnancy and RDTs performed better than microscopy in diagnosing PAM. In areas where intermittent preventive treatment during pregnancy may be abandoned due to low and decreasing malaria risk and instead replaced with active case management, screening with RDT is likely to identify most infections in pregnant women and out-performs microscopy as a diagnostic tool. PMID:22720788

  3. Two-step glutamate dehydrogenase antigen real-time polymerase chain reaction assay for detection of toxigenic Clostridium difficile.

    PubMed

    Goldenberg, S D; Cliff, P R; Smith, S; Milner, M; French, G L

    2010-01-01

    Current diagnosis of Clostridium difficile infection (CDI) relies upon detection of toxins A/B in stool by enzyme immunoassay [EIA(A/B)]. This strategy is unsatisfactory because it has a low sensitivity resulting in significant false negatives. We investigated the performance of a two-step algorithm for diagnosis of CDI using detection of glutamate dehydrogenase (GDH). GDH-positive samples were tested for C. difficile toxin B gene (tcdB) by polymerase chain reaction (PCR). The performance of the two-step protocol was compared with toxin detection by the Meridian Premier EIA kit in 500 consecutive stool samples from patients with suspected CDI. The reference standard among samples that were positive by either EIA(A/B) or GDH testing was culture cytotoxin neutralisation (culture/CTN). Thirty-six (7%) of 500 samples were identified as true positives by culture/CTN. EIA(A/B) identified 14 of the positive specimens with 22 false negatives and two false positives. The two-step protocol identified 34 of the positive samples with two false positives and two false negatives. EIA(A/B) had a sensitivity of 39%, specificity of 99%, positive predictive value of 88% and negative predictive value of 95%. The two-step algorithm performed better, with corresponding values of 94%, 99%, 94% and 99% respectively. Screening for GDH before confirmation of positives by PCR is cheaper than screening all specimens by PCR and is an effective method for routine use. Current EIA(A/B) tests for CDI are of inadequate sensitivity and should be replaced; however, this may result in apparent changes in CDI rates that would need to be explained in national surveillance statistics. Copyright 2009 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  4. The Relationships between Air Exposure, Negative Pressure and Hemolysis

    PubMed Central

    Pohlmann, Joshua R.; Toomasian, John M.; Hampton, Claire E.; Cook, Keith E.; Annich, Gail M.; Bartlett, Robert H.

    2013-01-01

    The purpose of this study was to describe the hemolytic effects of both negative pressure and an air-blood interface independently and in combination in an in-vitro static blood model. Samples of fresh ovine or human blood (5 mL) were subjected to a bubbling air interface (0–100 mL/min) or negative pressure (0–600 mmHg) separately, or in combination, for controlled periods of time, and analyzed for hemolysis. Neither negative pressure nor an air interface alone increased hemolysis. However, when air and negative pressure were combined, hemolysis increased as a function of negative pressure, the air interface, and time. Moreover, when blood samples were exposed to air prior to initiating the test, hemolysis was 4–5 times greater than samples not pre-exposed to air. When these experiments were repeated using freshly drawn human blood the same phenomena were observed, but the hemolysis was significantly higher than that observed in sheep blood. In this model, hemolysis is caused by combined air and negative pressure and is unrelated to either factor alone. PMID:19730004

  5. Evaluation of a Community's Risk for Canine Parvovirus and Distemper Using Antibody Testing and GIS Mapping of Animal Shelter Intakes.

    PubMed

    Spindel, Miranda E; Krecic, Matthew R; Slater, Margaret R; Vigil, Nicole

    2018-03-20

    This cross-sectional study aimed to identify where dogs with negative antibody tests to canine parvovirus (CPV) and canine distemper virus (CDV) originated when entering a community shelter, using a commercially available ELISA antibody test and Geographic Information Systems mapping. Of 2745 canines entering during a three-month period, 1056 test results were obtained. Dogs or puppies weighing over 2 lb were eligible if they could be humanely, nonchemically restrained for phlebotomy. Age and minor health issues weren't exclusions. Dogs were excluded if trained personnel were concerned health would be compromised by phlebotomy. Blood samples were collected within 24 hours of entry. Four hundred and twenty-seven (40%) dogs had positive antibody test results for both viruses, 422 (40%) were positive for CPV, 37 (4%) were positive for CDV, and 170 (16%) were negative for both. Mapping revealed geographic patterns for dogs with negative antibody tests. This shelter admitted dogs with negative CPV and/or CDV antibody tests from defined community areas. Targeting vaccination efforts in communities to areas where dogs with negative antibody tests originate could be an effective wellness strategy.

  6. A novel comprehensive set of fungal Real time PCR assays (fuPCR) for the detection of fungi in immunocompromised haematological patients-A pilot study.

    PubMed

    Rahn, Sebastian; Schuck, Anna; Kondakci, Mustafa; Haas, Rainer; Neuhausen, Nicole; Pfeffer, Klaus; Henrich, Birgit

    2016-12-01

    Fungal infections are recognized in an increasing number of patients with immunological deficits and are associated with high rates of mortality (Brown et al., 2012a). In this pilot-study, a rapid Real time PCR (fuPCR) was designed for the detection and differentiation of fungal pathogens in clinical specimens of haematological patients. The fuPCR, targeting the internal transcribed spacer region 2 (ITS2) of rDNA region, is comprised of seven multiplex reactions, which were shown to be specific and sensitive for a comprehensive spectrum of clinically relevant fungal species. This was validated by testing respective fungal DNAs in each fuPCR reaction and 28 respiratory samples of fungal pneumonia-proven patients. Clinical sample sets of throat swab, EDTA-blood and blood sera from 50 patients with severe haematological malignancies, including haematopoietic stem cell transfer (HSCT), and samples from 30 healthy individuals were then analysed. In a first step, 198 samples of immunosuppressed patients were solely examined by fuPCR; and 50.8% (33/65) respiratory swabs, 4.8% (3/63) EDTA blood samples and 1.4% (1/70) blood serum samples were tested positive. In a second step, 56 respiratory samples of immunosuppressed patients and 30 of healthy individuals were simultaneously analysed by fuPCR and standard cultivation techniques. By both methods 30.4% (17/56) swabs of the immunocompromised patients were tested positive, 37.5% (21/56) were tested negative and 32.1% (18/56) were tested fuPCR positive and culture negative. In analysing the blood samples of the immunocompromised patients 5.4% (3/56) EDTA blood samples and 16.1% (9/56) sera samples were tested fuPCR-positive, whereas all samples of 30 healthy individuals with no signs of immunological deficits were tested negative by fuPCR. 38.9% (14/36) of the fungi detected in respiratory samples of the immunosuppressed patients, belonged to Candida spp., 47.2% (17/36) to Saccharomyces spp., 5.6% (2/36) to Cladosporium spp. and 8.3% (3/36) to Alternaria spp., whereas cultivation only identified Candida spp. (10/17) and Saccharomyces spp. (7/17). In this pilot study a novel fuPCR assay was developed and validated for the simultaneous and comprehensive detection of fungal pathogens in clinical respiratory specimens of haematological patients. Future work will focus on the validation of the blood-stream detected fungi in pathogenicity of these patients. Copyright © 2016 Elsevier GmbH. All rights reserved.

  7. Incidence of anti-intermediate filament antibody in serum samples of students with suspected glandular fever.

    PubMed

    Kataaha, P K; Holborow, E J; Edwards, J M

    1985-03-01

    Serum samples from 40 students with suspected infectious mononucleosis were tested for the presence of antibodies to intermediate filaments (AIFA) of the cytoskeleton. Twenty had antibodies to the Epstein-Barr virus capsid antigen before their illness, and during it their sera remained negative by the Paul-Bunnell test. The other 20 patients did not have antibodies to the Epstein-Barr virus capsid antigen before their illness and seroconverted during the illness. These patients (true infectious mononucleosis group) developed positive Paul-Bunnell tests. Sera from normal subjects (blood donors) were also tested for AIFA. AIFA was present in titres greater than 1/10 in 80% of the infectious mononucleosis group (mean titre 1/40-1/80), 10% of the Paul-Bunnell negative glandular fever group, and 8.5% of the normal blood donors.

  8. Sensitivity and Specificity of Histoplasma Antigen Detection by Enzyme Immunoassay.

    PubMed

    Cunningham, Lauren; Cook, Audrey; Hanzlicek, Andrew; Harkin, Kenneth; Wheat, Joseph; Goad, Carla; Kirsch, Emily

    2015-01-01

    The objective of this study was to evaluate the sensitivity and specificity of an antigen enzyme immunoassay (EIA) on urine samples for the diagnosis of histoplasmosis in dogs. This retrospective medical records review included canine cases with urine samples submitted for Histoplasma EIA antigen assay between 2007 and 2011 from three veterinary institutions. Cases for which urine samples were submitted for Histoplasma antigen testing were reviewed and compared to the gold standard of finding Histoplasma organisms or an alternative diagnosis on cytology or histopathology. Sensitivity, specificity, negative predictive value, positive predictive value, and the kappa coefficient and associated confidence interval were calculated for the EIA-based Histoplasma antigen assay. Sixty cases met the inclusion criteria. Seventeen cases were considered true positives based on identification of the organism, and 41 cases were considered true negatives with an alternative definitive diagnosis. Two cases were considered false negatives, and there were no false positives. Sensitivity was 89.47% and the negative predictive value was 95.35%. Specificity and the positive predictive value were both 100%. The kappa coefficient was 0.9207 (95% confidence interval, 0.8131-1). The Histoplasma antigen EIA test demonstrated high specificity and sensitivity for the diagnosis of histoplasmosis in dogs.

  9. Mediating Effects of Global Negative Effect Expectancies on the Association between Problematic Cannabis Use and Social Anxiety.

    PubMed

    Di Blasi, Maria; Cavani, Paola; Pavia, Laura; Tosto, Crispino; La Grutta, Sabina; Lo Baido, Rosa; Giordano, Cecilia; Schimmenti, Adriano

    2017-01-01

    The relationship between social anxiety (SA) and cannabis use among adolescents and young adults is a highly debated topic. In this cross-sectional study, we tested whether cannabis use expectancies mediated the association between SA and cannabis use severity in a sample of 343 young adults (74.3% male) who used cannabis. They completed self-report measures for the screening of problematic cannabis use (Cannabis Use Problems Identification Test) and SA symptoms (Social Interaction Anxiety Scale and Social Phobia Scale). A multiple mediation analysis was used to test whether marijuana effect expectancies mediate SA effect on problematic cannabis use. SA was negatively associated with cannabis use severity in this sample, and we found evidence that cannabis use expectancies fully mediated this relationship. Specifically, global negative effect expectancies influence the relationship between SA and problematic cannabis use. These findings may inform current prevention strategies and clinical intervention for young adults who use cannabis.

  10. Mediating Effects of Global Negative Effect Expectancies on the Association between Problematic Cannabis Use and Social Anxiety

    PubMed Central

    Di Blasi, Maria; Cavani, Paola; Pavia, Laura; Tosto, Crispino; La Grutta, Sabina; Lo Baido, Rosa; Giordano, Cecilia; Schimmenti, Adriano

    2017-01-01

    The relationship between social anxiety (SA) and cannabis use among adolescents and young adults is a highly debated topic. In this cross-sectional study, we tested whether cannabis use expectancies mediated the association between SA and cannabis use severity in a sample of 343 young adults (74.3% male) who used cannabis. They completed self-report measures for the screening of problematic cannabis use (Cannabis Use Problems Identification Test) and SA symptoms (Social Interaction Anxiety Scale and Social Phobia Scale). A multiple mediation analysis was used to test whether marijuana effect expectancies mediate SA effect on problematic cannabis use. SA was negatively associated with cannabis use severity in this sample, and we found evidence that cannabis use expectancies fully mediated this relationship. Specifically, global negative effect expectancies influence the relationship between SA and problematic cannabis use. These findings may inform current prevention strategies and clinical intervention for young adults who use cannabis. PMID:29213247

  11. Serological diagnosis of canine leishmaniosis: comparison of three commercially available tests.

    PubMed

    Wolf, Denis; Failing, Klaus; Taubert, Anja; Pantchev, Nikola

    2014-05-01

    Quantitative serology is an important tool in canine leishmaniosis diagnostics from clinical and epidemiological points of view. Serologic diagnosis in laboratories is traditionally carried out by immunofluorescent antibody test (IFAT), but enzyme-linked immunosorbent assays (ELISA) are being increasingly employed. Two commercially available ELISAs (LEISHMANIA-ELISA DOG® [LED] and INGEZIM LEISHMANIA® [IL]) for the detection of Leishmania infantum infection in dogs were compared with the classical IFAT technique. Ninety-two canine serum samples covering a broad range of IFAT titers were chosen for evaluation. Titers ranged from negative (<1:50) to high (>1:3,200). Statistical analysis showed high correlation between all three assays for both negative and positive IFAT-tested samples as described by respective Spearman's rank correlation coefficient (r s), but results varied for samples with inconclusive IFAT titers (1:50-1:100) with IL stating samples predominantly negative. The highest accordance was found between LED and IFAT (percentage of identical results = 83.7%; r(s) = 0.90, p < 0.0001). IL showed higher analogy with LED (accordance = 81.5%; r(s )= 0.88, p < 0.0001) than with IFAT (73.9%; r(s) = 0.80, p < 0.0001). The distribution of the different ELISA scores is discussed and grouped according to correspondent IFAT titers to familiarize practitioners with the range of these tests since antibody levels play an important role in clinical management of canine patients with L. infantum infection.

  12. Experimental Design for a Macrofoam Swab Study Relating the Recovery Efficiency and False Negative Rate to Low Concentrations of Two Bacillus anthracis Surrogates on Four Surface Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piepel, Gregory F.; Hutchison, Janine R.

    2014-04-16

    This report describes the experimental design for a laboratory study to quantify the recovery efficiencies and false negative rates of a validated, macrofoam swab sampling method for low concentrations of Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus (BG) spores on four surface materials (stainless steel, glass, vinyl tile, plastic light cover panel). Two analytical methods (plating/counting and polymerase chain reaction) will be used. Only one previous study has investigated false negative as a function of affecting test factors. The surrogates BAS and BG have not been tested together in the same study previously. Hence, this study will provide for completingmore » gaps in the available information on the performance of macrofoam swab sampling at low concentrations.« less

  13. Experimental Design for a Macrofoam-Swab Study Relating the Recovery Efficiency and False Negative Rate to Low Concentrations of Two Bacillus anthracis Surrogates on Four Surface Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piepel, Gregory F.; Hutchison, Janine R.

    This report describes the experimental design for a laboratory study to quantify the recovery efficiencies and false negative rates of a validated, macrofoam-swab sampling method for low concentrations of Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus (BG) spores on four surface materials (stainless steel, glass, vinyl tile, plastic light cover panel). Two analytical methods (culture and polymerase chain reaction) will be used. Only one previous study has investigated how the false negative rate depends on test factors. The surrogates BAS and BG have not been tested together in the same study previously. Hence, this study will provide for completing gapsmore » in the available information on the performance of macrofoam-swab sampling at low concentrations.« less

  14. Performance of a New Rapid Immunoassay Test Kit for Point-of-Care Diagnosis of Significant Bacteriuria

    PubMed Central

    Cox, Marsha E.; DiNello, Robert K.; Geisberg, Mark; Abbott, April; Roberts, Pacita L.; Hooton, Thomas M.

    2015-01-01

    Urinary tract infections (UTIs) are frequently encountered in clinical practice and most commonly caused by Escherichia coli and other Gram-negative uropathogens. We tested RapidBac, a rapid immunoassay for bacteriuria developed by Silver Lake Research Corporation (SLRC), compared with standard bacterial culture using 966 clean-catch urine specimens submitted to a clinical microbiology laboratory in an urban academic medical center. RapidBac was performed in accordance with instructions, providing a positive or negative result in 20 min. RapidBac identified as positive 245/285 (sensitivity 86%) samples with significant bacteriuria, defined as the presence of a Gram-negative uropathogen or Staphylococcus saprophyticus at ≥103 CFU/ml. The sensitivities for Gram-negative bacteriuria at ≥104 CFU/ml and ≥105 CFU/ml were 96% and 99%, respectively. The specificity of the test, detecting the absence of significant bacteriuria, was 94%. The sensitivity and specificity of RapidBac were similar on samples from inpatient and outpatient settings, from male and female patients, and across age groups from 18 to 89 years old, although specificity was higher in men (100%) compared with that in women (92%). The RapidBac test for bacteriuria may be effective as an aid in the point-of-care diagnosis of UTIs especially in emergency and primary care settings. PMID:26063858

  15. Middle East Respiratory Syndrome Coronavirus Antibody Reactors Among Camels in Dubai, United Arab Emirates, in 2005

    PubMed Central

    Alexandersen, S; Kobinger, G P; Soule, G; Wernery, U

    2014-01-01

    We tested, using a low starting dilution, sequential serum samples from dromedary camels, sheep and horses collected in Dubai from February/April to October of 2005 and from dromedary camels for export/import testing between Canada and USA in 2000–2001. Using a standard Middle East respiratory syndrome coronavirus (MERS-CoV) neutralization test, serial sera from three sheep and three horses were all negative while sera from 9 of 11 dromedary camels from Dubai were positive for antibodies supported by similar results in a MERS-CoV recombinant partial spike protein antibody ELISA. The two negative Dubai camels were both dromedary calves and remained negative over the 5 months studied. The six dromedary samples from USA and Canada were negative in both tests. These results support the recent findings that infection with MERS-CoV or a closely related virus is not a new occurrence in camels in the Middle East. Therefore, interactions of MERS-CoV at the human–animal interface may have been ongoing for several, perhaps many, years and by inference, a widespread pandemic may be less likely unless significant evolution of the virus allow accelerated infection and spread potential in the human population. PMID:24456414

  16. CMV Disease in IBD: Comparison of Diagnostic Tests and Correlation with Disease Outcome.

    PubMed

    Johnson, Jessica; Affolter, Kajsa; Boynton, Kathleen; Chen, Xinjian; Valentine, John; Peterson, Kathryn

    2018-04-30

    Significance of cytomegalovirus (CMV) in inflammatory bowel disease (IBD) is unclear due to pathobiology, numerous CMV tests, and disparate treatment outcomes. Retrospective chart review was done on patients with positive qualitative CMV tissue polymerase chain reaction (PCR) from 2005-2013 at a tertiary referral hospital. Frequency of PCR+, hematoxylin and eosin staining(HE)+, histopathology and immunohistochemistry (IHC)+ was assessed. IHC was assessed on a sample of PCR- tissues. Surgery rates were correlated with CMV testing and treatment. PCR was done on 310 samples from 180 patients. Thirty-seven samples were PCR+ (51.4% PCR+ only, 35.1% IHC/PCR+, 13.5% HE/IHC/PCR+). The H&E frequently failed to detect CMV identified on extensive IHC. Of 13 PCR- samples tested with IHC, 100% were negative. Twenty-five patients were CMV+ (40% PCR+, 40% IHC/PCR+, 20% HE/IHC/PCR+). Surgery rates increased with number of positive tests: 60% in IHC/PCR+ and 80% in HE/IHC/PCR+, compared to 26.8% in PCR- or PCR+ (P = 0.03, P = 0.02, respectively). There were 20/25 PCR+ patients who received CMV treatment. Surgery occurred in 80% of HE+ patients despite treatment and 100% of IHC+ patients without treatment. Rates of CMV+ testing and surgical risk varied by test modality. PCR+ results were most frequent but alone did not detect clinically significant CMV. HE+ testing was least frequent and associated with highest surgical rate, despite treatment. CMV treatment may benefit IHC+ patients most, supporting immunostaining as optimal diagnostic test for clinically significant CMV in IBD. In PCR+ samples, HE frequently did not detect CMV identified on extensive IHC. In PCR- samples, data suggest IHC is likely negative. Consider using qualitative PCR to guide extensive immunostaining.

  17. Detecting negative selection on recurrent mutations using gene genealogy

    PubMed Central

    2013-01-01

    Background Whether or not a mutant allele in a population is under selection is an important issue in population genetics, and various neutrality tests have been invented so far to detect selection. However, detection of negative selection has been notoriously difficult, partly because negatively selected alleles are usually rare in the population and have little impact on either population dynamics or the shape of the gene genealogy. Recently, through studies of genetic disorders and genome-wide analyses, many structural variations were shown to occur recurrently in the population. Such “recurrent mutations” might be revealed as deleterious by exploiting the signal of negative selection in the gene genealogy enhanced by their recurrence. Results Motivated by the above idea, we devised two new test statistics. One is the total number of mutants at a recurrently mutating locus among sampled sequences, which is tested conditionally on the number of forward mutations mapped on the sequence genealogy. The other is the size of the most common class of identical-by-descent mutants in the sample, again tested conditionally on the number of forward mutations mapped on the sequence genealogy. To examine the performance of these two tests, we simulated recurrently mutated loci each flanked by sites with neutral single nucleotide polymorphisms (SNPs), with no recombination. Using neutral recurrent mutations as null models, we attempted to detect deleterious recurrent mutations. Our analyses demonstrated high powers of our new tests under constant population size, as well as their moderate power to detect selection in expanding populations. We also devised a new maximum parsimony algorithm that, given the states of the sampled sequences at a recurrently mutating locus and an incompletely resolved genealogy, enumerates mutation histories with a minimum number of mutations while partially resolving genealogical relationships when necessary. Conclusions With their considerably high powers to detect negative selection, our new neutrality tests may open new venues for dealing with the population genetics of recurrent mutations as well as help identifying some types of genetic disorders that may have escaped identification by currently existing methods. PMID:23651527

  18. How Reliable Is the Alpha-defensin Immunoassay Test for Diagnosing Periprosthetic Joint Infection? A Prospective Study.

    PubMed

    Bonanzinga, Tommaso; Zahar, Akos; Dütsch, Michael; Lausmann, Christian; Kendoff, Daniel; Gehrke, Thorsten

    2017-02-01

    A key issue in the treatment of periprosthetic joint infection (PJI) is the correct diagnosis. The main problem is lack of diagnostic tools able to diagnose a PJI with high accuracy. Alpha-defensin has been proposed as a possible solution, but in the current literature, there is a lack of independent validation. We performed a prospective study to determine (1) what is the sensitivity, specificity, and positive and the negative predictive values of the alpha-defensin immunoassay test in diagnosing PJI; and (2) which clinical features may be responsible for false-positive and false-negative results? Preoperative aspiration was performed in all patients presenting with a painful hip/knee arthroplasty, including both primary and revision implants. Metallosis, other inflammatory comorbidities, and previous/concomitant antibiotic therapy were not considered as exclusion criteria. An inadequate amount of synovial fluid for culture was an exclusion criterion. A total of 156 patients (65 knees, 91 hips) were included in this prospective study. At the time of revision, synovial fluid samples were taken to perform the alpha-defensin assay. During surgical débridement of tissue, samples for cultures and histologic evaluation were taken, and samples were cultured until positive or until negative at 14 days. A diagnosis of PJI was confirmed in 29 patients according to the International Consensus Group on PJI. The sensitivity of the alpha-defensin immunoassay was 97% (95% confidence interval [CI], 92%-99%), the specificity was 97% (95% CI, 92%-99%), the positive predictive value was 88% (95% CI, 81%-92%), and the negative predictive value was 99% (95% CI, 96%-99%). Among four false-positive patients, two had metallosis and one had polyethylene wear. The false-negative case presented with a draining sinus, and intraoperative cultures were also negative. Alpha-defensin assay appears to be a reliable test, but followup evaluation is needed to estimate longer term performance of the test. The authors believe that alpha-defensin has demonstrated itself to be sufficiently robust that PJI diagnostic criteria now should include this test. Future studies are needed to compare the differences among the diagnostic capability of the available tests, in particular when metallosis is present, because metallosis may predispose the test to a false-positive result. Level I, diagnostic study.

  19. [Applying competitive polymerase chain reaction to the detection of hepatitis B virus DNA].

    PubMed

    Wang, Ling; Yang, Peng; Li, Shuang-qing; Xu, Shu-hui; Cao, Gui-qun; Zhang, Fa-qiang; Zhang, Mei-xia; Chen, Qing-ying; Xia, Qing-jie; Liu, Kai; Tang, Fang; Zhang, Yuan-zheng

    2004-11-01

    To reduce the rate of accidental false negative result in the HBV DNA PCR test on clinical serum samples. A competitive polymerase chain reaction (C-PCR) was used to decrease the false negative ratio. In the C-PCR, a constructed inner control DNA was added for co-amplification with the HBV target DNA. In a 20 microl C-PCR system, about 60 to 200 copies of inner control DNA could give apparent co-amplification signal band after electrophoresis on a 2% agarose gel. Five of 120 samples of clinical serum (4.2%) could not be amplified. C-PCR has the advantage of yielding information on false negative in the HBV DNA PCR assay of clinical serum samples.

  20. Evaluation of Petrifilms(TM) as a diagnostic test to detect bovine mastitis organisms in Kenya.

    PubMed

    Gitau, George K; Bundi, Royford M; Vanleeuwen, John; Mulei, Charles M

    2013-03-01

    The study purpose was to validate Petrifilms(TM) (3M Microbiology, 2005) against standard culture methods in the diagnosis of bovine mastitis organisms in Kenya. On 128 smallholder dairy cattle farms in Kenya, between June 21, 2010 and August 31, 2010, milk samples from 269 cows that were positive on California Mastitis Test (CMT) were cultured using standard laboratory culture methods and Petrifilms(TM) (Aerobic Count and Coliform Count -3M Microbiology, 2005), and results were compared. Staphylococcus aureus was the most common bacterium isolated (73 % of samples). Clinical mastitis was found in only three cows, and there were only two Gram-negative isolates, making it impossible to examine the agreement between the two tests for Gram-negative- or clinical mastitis samples. The observed agreement between the standard culture and Petrifilm(TM) (3M Microbiology, 2005) results for Gram-positive isolates was 85 %, and there was fair agreement beyond that expected due to chance alone, with a kappa (κ) of 0.38. Using culture results as a gold standard, the Petrifilms(TM) had a sensitivity of 90 % for Gram-positive samples and specificity of 51 %. With 87 % of CMT-positive samples resulting in Gram-positive pathogens cultured, there was a positive predictive value of 93 % and a negative predictive value of 43 %. Petrifilms(TM) should be considered for culture of mastitis organisms in developing countries, especially when Gram-positive bacteria are expected.

  1. Simplified PCR for detection of Haemophilus ducreyi and diagnosis of chancroid.

    PubMed Central

    West, B; Wilson, S M; Changalucha, J; Patel, S; Mayaud, P; Ballard, R C; Mabey, D

    1995-01-01

    A simplified PCR was developed for detection of Haemophilus ducreyi in samples from chancroid patients. The strategy included a straightforward chloroform extraction sample preparation method, a one-tube nested PCR to minimize contamination risks, and a colorimetric method for detection of products. Primers were designed from published nucleotide sequences of the 16S rRNA gene of H. ducreyi, with longer outer primers for annealing at a higher temperature and shorter inner primers labelled with biotin and digoxigenin for binding with avidin and colorimetric detection. The PCR technique detected all 35 strains of H. ducreyi tested, from four different geographical regions, and was negative for other, related strains of bacteria and for the common contaminating bacteria tested. Of 25 samples from H. ducreyi culture-positive chancroid patients, 24 were PCR positive and 1 produced a weak reaction. Of 83 samples from clinical cases of chancroid in the Republic of South Africa, 69 were PCR positive. The sensitivity of PCR compared with that of clinical diagnosis was 83%. All 50 negative control samples were negative. Encouraging results were also obtained with a consecutive series of 25 genital ulcer patients in Tanzania, of whom 9 were PCR positive. The adaptations of this simplified PCR strategy, at the sensitivity and specificity levels obtained, mean it will be useful for detection of H. ducreyi in areas where the organism is endemic, particularly where testing by culture is difficult or impossible. PMID:7540625

  2. Induced sputum and bronchoscopy in the diagnosis of pulmonary tuberculosis

    PubMed Central

    McWilliams, T; Wells, A; Harrison, A; Lindstrom, S; Cameron, R; Foskin, E

    2002-01-01

    Background: Previous studies suggest that bronchoscopy and a single induced sputum sample are equally effective for diagnosing pulmonary tuberculosis. Methods: In a prospective study of subjects with possibly active pulmonary tuberculosis, the diagnostic yield of three induced sputum tests was compared with that of bronchoscopy. Subjects either produced no sputum or (acid fast) smear negative sputum. Bronchoscopy was only performed if at least two induced sputum samples were smear negative. Results: Of 129 subjects who completed all tests, 27 (21%) had smear negative and culture positive specimens, 14 (52%) on bronchoscopy and 26 (96%) on induced sputum (p<0.005). One patient was culture positive on bronchoscopy alone compared with 13 on induced sputum alone; 13 were culture positive on both tests. Induced sputum positivity was strikingly more prevalent when chest radiographic appearances showed any features of active tuberculosis (20/63, 32%) than when appearances suggested inactivity (1/44, 2%; p<0.005). Induced sputum costs were about one third those of bronchoscopy, and the ratio of costs of the two tests per case of tuberculosis diagnosed could be as much as 1:6. Conclusions: In subjects investigated for possibly active or inactive tuberculosis who produce no sputum or have smear negative sputum, the most cost effective strategy is to perform three induced sputum tests without bronchoscopy. Induced sputum testing carries a high risk of nosocomial tuberculosis unless performed in respiratory isolation conditions. The cost benefits shown could be lost if risk management measures are not observed. PMID:12454293

  3. HIV rapid diagnostic testing by lay providers in a key population-led health service programme in Thailand.

    PubMed

    Wongkanya, Rapeeporn; Pankam, Tippawan; Wolf, Shauna; Pattanachaiwit, Supanit; Jantarapakde, Jureeporn; Pengnongyang, Supabhorn; Thapwong, Prasopsuk; Udomjirasirichot, Apichat; Churattanakraisri, Yutthana; Prawepray, Nanthika; Paksornsit, Apiluk; Sitthipau, Thidadaow; Petchaithong, Sarayut; Jitsakulchaidejt, Raruay; Nookhai, Somboon; Lertpiriyasuwat, Cheewanan; Ongwandee, Sumet; Phanuphak, Praphan; Phanuphak, Nittaya

    2018-01-01

    Introduction:  Rapid diagnostic testing (RDT) for HIV has a quick turn-around time, which increases the proportion of people testing who receive their result. HIV RDT in Thailand has traditionally been performed only by medical technologists (MTs), which is a barrier to its being scaled up. We evaluated the performance of HIV RDT conducted by trained lay providers who were members of, or worked closely with, a group of men who have sex with men (MSM) and with transgender women (TG) communities, and compared it to tests conducted by MTs. Methods:  Lay providers received a 3-day intensive training course on how to perform a finger-prick blood collection and an HIV RDT as part of the Key Population-led Health Services (KPLHS) programme among MSM and TG. All the samples were tested by lay providers using Alere Determine HIV 1/2. HIV-reactive samples were confirmed by DoubleCheckGold Ultra HIV 1&2 and SD Bioline HIV 1/2. All HIV-positive and 10% of HIV-negative samples were re-tested by MTs using Serodia HIV 1/2. Results:  Of 1680 finger-prick blood samples collected and tested using HIV RDT by lay providers in six drop-in centres in Bangkok, Chiang Mai, Chonburi and Songkhla, 252 (15%) were HIV-positive. MTs re-tested these HIV-positive samples and 143 randomly selected HIV-negative samples with 100% concordant test results. Conclusion:  Lay providers in Thailand can be trained and empowered to perform HIV RDT as they were found to achieve comparable results in sample testing with MTs. Based on the task-shifting concept, this rapid HIV testing performed by lay providers as part of the KPLHS programme has great potential to enhance HIV prevention and treatment programmes among key at-risk populations.

  4. Asymptomatic Plasmodium Infections in Children in Low Malaria Transmission Setting, Southwestern Uganda(1).

    PubMed

    Roh, Michelle E; Oyet, Caesar; Orikiriza, Patrick; Wade, Martina; Kiwanuka, Gertrude N; Mwanga-Amumpaire, Juliet; Parikh, Sunil; Boum, Yap

    2016-08-01

    A survey of asymptomatic children in Uganda showed Plasmodium malariae and P. falciparum parasites in 45% and 55% of microscopy-positive samples, respectively. Although 36% of microscopy-positive samples were negative by rapid diagnostic test, 75% showed P. malariae or P. ovale parasites by PCR, indicating that routine diagnostic testing misses many non-P. falciparum malarial infections.

  5. Element Specific Imaging Using Muonic X-rays

    NASA Astrophysics Data System (ADS)

    Hillier, Adrian; Ishida, Katsu; Seller, Paul; Veale, Matthew C.; Wilson, Matthew D.

    The RIKEN-RAL facility provides a source of negative muons that can be used to non-destructively determine the elemental composition of bulk samples. A negative muon can replace an electron in an atom and subsequently transition to lower orbital positions. As with conventional X-ray fluorescence, an X-ray photon is emitted with a characteristic energy to enable the transition between orbitals of an atom. As the mass of a negative muon is much greater than that of an electron, a higher energy X-ray photon is emitted when the negative muon transitions between orbitals compared to conventional X-ray fluorescence. The higher energy muonic X-rays are able to escape large samples even when they are emitted from lower Z atoms, making muonic X-rays fluorescence a unique method to characterize the elemental content of a sample. In a typical experiment a section of a sample will be probed with negative muons with the muon momentum tuned to interact at a desired depth in the sample. A small number of single element high purity Ge detectors are positioned to capture up to one photon each from each of the forty muon pulses per second at the RIKEN-RAL facility. This can provide a high resolution and high dynamic range X-ray energy spectrum when collected for several hours but can only provide a spatial average or single point elemental distribution per collection. Here, an STFC developed CdTe detector with 80 × 80 energy resolving channels has been used to demonstrate the ability to image the elemental distribution of a test sample. A test sample of C, Al, and Fe2O3 was positioned close to the detector surface and each of the 250 µm pitch pixels recorded a muonic X-ray energy spectrum. Results are presented to show the principal of this new technique and potential improvements to provide higher resolution and larger area elemental imaging using muonic X-rays are discussed.

  6. Is Follow-Up Testing with the FilmArray Gastrointestinal Multiplex PCR Panel Necessary?

    PubMed Central

    Park, Sholhui; Hitchcock, Matthew M.; Gomez, Carlos A.

    2017-01-01

    ABSTRACT The FilmArray gastrointestinal (GI) panel (BioFire Diagnostics, Salt Lake City, UT) is a simple, sample-to-answer, on-demand, multiplex, nucleic acid amplification test for syndromic diagnosis of infectious gastroenteritis. The aim of this study was to measure the yield of follow-up testing with FilmArray GI panel within 4 weeks of an initial test. Consecutive adult and pediatric patients tested at an academic institution between August 2015 and June 2016 were included in this study. Of 145 follow-up tests in 106 unique patients with an initial negative result, 134 (92.4%) tests and 98 (92.5%) patients remained negative upon follow-up testing. Excluding targets that are not reported at this institution (Clostridium difficile, enteroaggregative Escherichia coli, enteropathogenic E. coli, and enterotoxigenic E. coli), 137 (94.5%) follow-up tests and 101 (95.3%) patients remained negative. Weekly conversion rates were not significantly different across the 4-week follow-up interval. No epidemiological or clinical factors were significantly associated with a negative to positive conversion. Of 80 follow-up tests in patients with an initial positive result, 43 (53.8%) remained positive for the same target, 34 (42.5%) were negative, and 3 were positive for a different target (3.8%). Follow-up testing with FilmArray GI panel within 4 weeks of a negative result rarely changed the initial result, and the follow-up test reverted to negative less than half the time after an initial positive result. In the absence of clinical or epidemiological evidence for a new infection, follow-up testing should be limited and FilmArray GI panel should not be used as a test of cure. PMID:28122874

  7. Evaluation of immunohematologic routine methods using the new erythrocyte-magnetized technology on the QWALYS 2 system.

    PubMed

    Schoenfeld, Helge; Bulling, Katia; von Heymann, Christian; Neuner, Bruno; Kalus, Ulrich; Kiesewetter, Holger; Pruss, Axel

    2009-07-01

    QWALYS 2 is a fully automated system for ABO/D grouping, Rh phenotyping, K typing, and antibody screening (ABS). Its new erythrocyte-magnetized technology (EMT) is based on the use of magnetic nanoparticles and avoids centrifugation and washing steps. Overall 499 blood samples were tested with our routine blood bank methods for ABO/D grouping, 313 samples for Rh phenotyping and K typing (microtiter plates; Olympus PK 7200), and 478 samples for ABS (gel centrifugation technique, DiaMed). All samples were tested in parallel with the EMT. In 496 of 499 samples (99.4%), a complete concordance between the observed (QWALYS 2) and the expected results for ABO/D grouping was found. One sample with a weak A in an AB blood group and 2 samples with a weak D were not detected by the QWALYS system. Rh phenotyping and K tests revealed a 100% concordance. In the two ABS techniques, 427 samples were negative in both and 15 samples showed the same antibody specificity in both. Three immunoglobulin M antibodies were as expected negative in EMT and positive by DiaMed. In 32 cases (6.7%), false-positive reactions were observed by EMT due to 22 unspecific reactions (4.6%) and 10 lipemic or fibrinic plasmas (2.1%). One autoantibody was found by EMT only. The EMT is reliably suited to ABO/D grouping, Rh phenotyping, and K testing and is suitable to detect immunoglobulin G red blood cell alloantibodies as well. The rate of false-positive reactions in ABS due to lipemic and fibrinic samples needs to be reduced.

  8. Effect of urine creatinine level during pregnancy on dipstick test.

    PubMed

    Baba, Yosuke; Furuta, Itsuko; Zhai, Tianyue; Ohkuchi, Akihide; Yamada, Takahiro; Takahashi, Kayo; Matsubara, Shigeki; Minakami, Hisanori

    2017-06-01

    Dipstick results for proteinuria are affected by urine concentration, and thus urine creatinine concentration ([Cr]). This study was performed to determine whether spot urine [Cr] changes significantly during pregnancy, leading to a significantly different false-negative rate (FNR) on dipstick test between trimester. The [Cr] and protein concentrations ([P]) were analyzed in 631 spot urine samples with negative/equivocal dipstick from 425 pregnant women. False-negative dipstick was defined as [P] : [Cr] ratio (P/Cr) > 0.27 mg/mg. Median [Cr] was 117 mg/dL (range, 6.5-326 mg/dL), 72 mg/dL (range, 4.3-477 mg/dL), and 73 mg/dL (range, 8.4-396 mg/dL) in the first (n = 96), second (n = 344), and third (n = 191) trimester urine samples, respectively (P = 0.000, Kruskal-Wallis). Both [P] and P/Cr increased significantly with advancing gestation. FNR 9.4% (18/191) in the third trimester was significantly higher than that of 0.0% (0/96) in the second trimester and that of 0.5% (2/344) in the third trimester. In the 20 urine samples with false-negative dipstick, median [Cr] was 47.0 mg/dL (range, 11.0-358 mg/dL) and the proportion of samples with dilute urine, that is, [Cr] <47 mg/dL, was significantly higher than in the remaining 611 urine samples (50%, 10/20 vs 28%, 174/611, respectively, P = 0.046). Urine samples in the second and third trimesters were more likely to be diluted compared with the first trimester. This was associated with high FNR in third trimester urine samples. © 2017 Japan Society of Obstetrics and Gynecology.

  9. Bacterial and fungal biofilm formation on anodized titanium alloys with fluorine.

    PubMed

    Perez-Jorge, Concepcion; Arenas, Maria-Angeles; Conde, Ana; Hernández-Lopez, Juan-Manuel; de Damborenea, Juan-Jose; Fisher, Steve; Hunt, Alessandra M Agostinho; Esteban, Jaime; James, Garth

    2017-01-01

    Orthopaedic device-related infections are closely linked to biofilm formation on the surfaces of these devices. Several modified titanium (Ti-6Al-4V) surfaces doped with fluorine were studied in order to evaluate the influence of these modifications on biofilm formation by Gram-positive and Gram-negative bacteria as well as a yeast. The biofilm studies were performed according to the standard test method approved by ASTM (Designation: E2196-12) using the Rotating Disk Reactor. Four types of Ti-6Al-4V samples were tested; chemically polished (CP), two types of nanostructures containing fluorine, nanoporous (NP) and nanotubular (NT), and non-nanostructured fluorine containing samples (fluoride barrier layers, FBL). Different species of Gram-positive cocci, (Staphylococcus aureus and epidermidis), Gram-negative rods (Escherichia coli, Pseudomonas aeruginosa), and a yeast (Candida albicans) were studied. For one of the Gram-positive (S. epidermidis) and one of the Gram-negative (E. coli) species a statistically-significant decrease in biofilm accumulation for NP and NT samples was found when compared with the biofilm accumulation on CP samples. The results suggest an effect of the modified materials on the biofilm formation.

  10. The comparison of printed resources bacterial contamination in libraries of Al-Zahra Hospital and Sciences Faculty of Isfahan University and the determination of their antibiotic sensitivity pattern.

    PubMed

    Rafiei, Hosein; Chadeganipour, Mostafa; Ojaghi, Rezvan; Maracy, Mohammad Reza; Nouri, Rasool

    2017-01-01

    During the library loan process, the printed resources can be a carrier of pathogenic bacteria. In this study, it was tried to compare the Bacterial Contamination Rates and their antibiotic sensitivity pattern in printed resources of a hospital and a non-hospital library. This is a cross-sectional study. Returning books from the Al-Zahra hospital library and library of Sciences faculty of Isfahan University provides the research community. The sample size, 96 cases, was calculated using quota sampling. For sampling sterile swab dipped in trypticase soy broth medium and transfer trypticase soy broth medium were used. To identify different type of isolated bacteria from Gram-staining test and biochemical tests such as; TSI, IMViC and etc., were used. 76 (79.2%) and 20 (20.8%) of cultured samples were negative and positive, the respectively. Of 20 positive samples, 11 samples (55%) belong to the family Enterobacteriaceae that after detecting by Differential teste identified all 11 samples of Enterobacter that all of them were sensitive to Gentamicin and Ofloxacin. Also the most resistance to Nitrofurantoin and Amikacin was observed. 9 cases remained (45%) were coagulase-negative Staphylococcus that all of them were sensitive to the Trimethoprim-sulfamethoxazole and Cephalexin antibiotics also the most resistance to Cefixime was observed. Considering that the Enterobacter sp and coagulase-negative Staphylococcus were separated from the books, the books as well as other hospital and medical equipment can transmit the infection to librarians, library users, patients and hospital staff, and also it can produce serious infections in patients with immune deficiency.

  11. The comparison of printed resources bacterial contamination in libraries of Al-Zahra Hospital and Sciences Faculty of Isfahan University and the determination of their antibiotic sensitivity pattern

    PubMed Central

    Rafiei, Hosein; Chadeganipour, Mostafa; Ojaghi, Rezvan; Maracy, Mohammad Reza; Nouri, Rasool

    2017-01-01

    Introduction: During the library loan process, the printed resources can be a carrier of pathogenic bacteria. In this study, it was tried to compare the Bacterial Contamination Rates and their antibiotic sensitivity pattern in printed resources of a hospital and a non-hospital library. Methods: This is a cross-sectional study. Returning books from the Al-Zahra hospital library and library of Sciences faculty of Isfahan University provides the research community. The sample size, 96 cases, was calculated using quota sampling. For sampling sterile swab dipped in trypticase soy broth medium and transfer trypticase soy broth medium were used. To identify different type of isolated bacteria from Gram-staining test and biochemical tests such as; TSI, IMViC and etc., were used. Results: 76 (79.2%) and 20 (20.8%) of cultured samples were negative and positive, the respectively. Of 20 positive samples, 11 samples (55%) belong to the family Enterobacteriaceae that after detecting by Differential teste identified all 11 samples of Enterobacter that all of them were sensitive to Gentamicin and Ofloxacin. Also the most resistance to Nitrofurantoin and Amikacin was observed. 9 cases remained (45%) were coagulase-negative Staphylococcus that all of them were sensitive to the Trimethoprim-sulfamethoxazole and Cephalexin antibiotics also the most resistance to Cefixime was observed. Conclusion: Considering that the Enterobacter sp and coagulase-negative Staphylococcus were separated from the books, the books as well as other hospital and medical equipment can transmit the infection to librarians, library users, patients and hospital staff, and also it can produce serious infections in patients with immune deficiency. PMID:28546984

  12. Missed diagnostic opportunities within South Africa's early infant diagnosis program, 2010-2015.

    PubMed

    Haeri Mazanderani, Ahmad; Moyo, Faith; Sherman, Gayle G

    2017-01-01

    Samples submitted for HIV PCR testing that fail to yield a positive or negative result represent missed diagnostic opportunities. We describe HIV PCR test rejections and indeterminate results, and the associated delay in diagnosis, within South Africa's early infant diagnosis (EID) program from 2010 to 2015. HIV PCR test data from January 2010 to December 2015 were extracted from the National Health Laboratory Service Corporate Data Warehouse, a central data repository of all registered test-sets within the public health sector in South Africa, by laboratory number, result, date, facility, and testing laboratory. Samples that failed to yield either a positive or negative result were categorized according to the rejection code on the laboratory information system, and descriptive analysis performed using Microsoft Excel. Delay in diagnosis was calculated for patients who had a missed diagnostic opportunity registered between January 2013 and December 2015 by means of a patient linking-algorithm employing demographic details. Between 2010 and 2015, 2 178 582 samples were registered for HIV PCR testing of which 6.2% (n = 134 339) failed to yield either a positive or negative result, decreasing proportionally from 7.0% (n = 20 556) in 2010 to 4.4% (n = 21 388) in 2015 (p<0.001). Amongst 76 972 coded missed diagnostic opportunities, 49 585 (64.4%) were a result of pre-analytical error and 27 387 (35.6%) analytical error. Amongst 49 694 patients searched for follow-up results, 16 895 (34.0%) had at least one subsequent HIV PCR test registered after a median of 29 days (IQR: 13-57), of which 8.4% tested positive compared with 3.6% of all samples submitted for the same period. Routine laboratory data provides the opportunity for near real-time surveillance and quality improvement within the EID program. Delay in diagnosis and wastage of resources associated with missed diagnostic opportunities must be addressed and infants actively followed-up as South Africa works towards elimination of mother-to-child transmission.

  13. A misleading false-negative result using Neisseria gonorrhoeae opa MGB multiplex PCR assay in patient's rectal sample due to partial mutations of the opa gene.

    PubMed

    Vahidnia, Ali; van Empel, Pieter Jan; Costa, Sandra; Oud, Rob T N; van der Straaten, Tahar; Bliekendaal, Harry; Spaargaren, Joke

    2015-07-01

    A 53-year-old homosexual man presented at his general practitioner (GP) practice with a suspicion of sexually transmitted infection. Initial NAAT screening was performed for Chlamydia trachomatis and Neisseria gonorrhoeae. The patient was positive for Neisseria gonorrhoeae both for his urine and rectal sample. The subsequent confirmation test for Neisseria gonorrhoeae by a second laboratory was only confirmed for the urine sample and the rectal sample was negative. We report a case of a potential false-negative diagnosis of Neisseria gonorrhoeae due to mutations of DNA sequence in the probe region of opa-MGB assay of the rectal sample. The patient did not suffer any discomfort as diagnosis of Neisseria gonorrhoeae in his urine sample had already led to treatment by prescribing the patient with Ceftriaxone 500 mg IV dissolved in 1 ml lidocaine 2% and 4 mL saline. The patient also received a prescription for Azithromycin (2x500 mg).

  14. Testing a model of depression among Thai adolescents.

    PubMed

    Vatanasin, Duangjai; Thapinta, Darawan; Thompson, Elaine Adams; Thungjaroenkul, Petsunee

    2012-11-01

    This predictive correlational study was designed to test a comprehensive model of depression for Thai adolescents. This sample included 800 high school students in Chiang Mai, Thailand. Data were collected using self-reported measures of depression, negative automatic thoughts, effective social problem solving, ineffective social problem solving, rumination, parental care, parental overprotection, and negative life events. Structural equation modeling revealed that negative automatic thoughts, effective and ineffective social problem solving mediated the effects of rumination, negative life events, and parental care and overprotection on adolescent depression. These findings provide new knowledge about identified factors and the mechanisms of their influence on depression among Thai adolescents, which are appropriate for targeting preventive interventions. © 2012 Wiley Periodicals, Inc.

  15. The Unique Effects of Parental Alcohol and Affective Disorders, Parenting, and Parental Negative Affect on Adolescent Maladjustment

    PubMed Central

    Haller, Moira; Chassin, Laurie

    2010-01-01

    Using a high-risk community sample, multiple regression analyses were conducted separately for mothers (N=416) and fathers (N= 346) to test the unique, prospective influence of parental negative affect on adolescent maladjustment (internalizing symptoms, externalizing symptoms, and negative emotionality) two years later over and above parental alcohol and affective disorders, major disruption in the family environment, and parenting. Adolescent sex was tested as a moderator. Results indicated that maternal (but not paternal) negative affect had a unique, prospective effect on adolescent internalizing symptoms in girls and negative emotionality in both sexes, but did not predict adolescent externalizing symptoms. Findings demonstrate that mothers’ negative affect may have unique effects on adolescent adjustment, separate from the effects of clinically significant parental psychopathology, parenting, and disruption in the family environment. PMID:23761947

  16. The Unique Effects of Parental Alcohol and Affective Disorders, Parenting, and Parental Negative Affect on Adolescent Maladjustment.

    PubMed

    Haller, Moira; Chassin, Laurie

    2011-07-01

    Using a high-risk community sample, multiple regression analyses were conducted separately for mothers ( N =416) and fathers ( N = 346) to test the unique, prospective influence of parental negative affect on adolescent maladjustment (internalizing symptoms, externalizing symptoms, and negative emotionality) two years later over and above parental alcohol and affective disorders, major disruption in the family environment, and parenting. Adolescent sex was tested as a moderator. Results indicated that maternal (but not paternal) negative affect had a unique, prospective effect on adolescent internalizing symptoms in girls and negative emotionality in both sexes, but did not predict adolescent externalizing symptoms. Findings demonstrate that mothers' negative affect may have unique effects on adolescent adjustment, separate from the effects of clinically significant parental psychopathology, parenting, and disruption in the family environment.

  17. Evaluation of non-extracted genital swabs for real-time HSV PCR.

    PubMed

    Miari, Victoria F; Wall, Gavin R; Clark, Duncan A

    2015-01-01

    Nucleic acid extraction of clinical samples is accepted as a key requirement in molecular diagnostics. At Barts Health NHS Trust, swabs taken from patients with clinical suspicion of HSV infection were routinely extracted on the Qiagen MDx BioRobot prior to testing with a real-time triplex PCR for HSV1, HSV2, and VZV. The aim of this study was to adapt an existing HSV1/HSV2/VZV real-time PCR by replacing VZV with phocine herpesvirus 1 (PhHV) as an internal control (IC) and evaluate whether this adapted assay required the nucleic acid extraction step for predominantly genital swabs. First 313 non-extracted and extracted swabs were tested in parallel with the existing triplex HSV1/HSV2/VZV real-time PCR. The second stage involved testing 176 non-extracted swabs using a triplex real-time PCR for HSV1, HSV2, and PhHV and comparing the results with the samples extracted and tested by the original triplex assay. The results correlated well when the existing assay was used, with only three non-extracted samples that would have been reported as negative compared to the extracted sample result (Cq s 33, 39, 35-two samples HSV1, one sample HSV2). In the evaluation using the adapted assay containing the IC, two of 176 samples were discordant, where a HSV negative non-extracted sample result would have been reported differently to the extracted sample result (Cq s 32, 33-both HSV1). This study demonstrated that it is feasible to test non-extracted swabs for HSV in a real-time PCR that includes an IC. J. Med. Virol. 87: 125-129, 2015. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  18. Detection of borreliae in archived sera from patients with clinically suspect Lyme disease.

    PubMed

    Lee, Sin Hang; Vigliotti, Jessica S; Vigliotti, Veronica S; Jones, William; Shearer, David M

    2014-03-11

    The diagnoses of Lyme disease based on clinical manifestations, serological findings and detection of infectious agents often contradict each other. We tested 52 blind-coded serum samples, including 20 pre-treatment and 12 post-treatment sera from clinically suspect Lyme disease patients, for the presence of residual Lyme disease infectious agents, using nested PCR amplification of a signature segment of the borrelial 16S ribosomal RNA gene for detection and direct DNA sequencing of the PCR amplicon for molecular validation. These archived sera were split from the samples drawn for the 2-tier serology tests performed by a CDC-approved laboratory, and are used as reference materials for evaluating new diagnostic reagents. Of the 12 post-treatment serum samples, we found DNA evidence of a novel borrelia of uncertain significance in one, which was also positive for the 2-tier serology test. The rest of the post-treatment sera and all 20 control sera were PCR-negative. Of the 20 pre-treatment sera from clinically suspect early Lyme disease patients, we found Borrelia miyamotoi in one which was 2-tier serology-negative, and a Borrelia burgdorferi in two-one negative and one positive for 2-tier serology. We conclude that a sensitive and reliable DNA-based test is needed to support the diagnosis of Lyme disease and Lyme disease-like borreliosis.

  19. Residual antibiotics in decontaminated human cardiovascular tissues intended for transplantation and risk of falsely negative microbiological analyses.

    PubMed

    Buzzi, Marina; Guarino, Anna; Gatto, Claudio; Manara, Sabrina; Dainese, Luca; Polvani, Gianluca; Tóthová, Jana D'Amato

    2014-01-01

    We investigated the presence of antibiotics in cryopreserved cardiovascular tissues and cryopreservation media, after tissue decontamination with antibiotic cocktails, and the impact of antibiotic residues on standard tissue bank microbiological analyses. Sixteen cardiovascular tissues were decontaminated with bank-prepared cocktails and cryopreserved by two different tissue banks according to their standard operating procedures. Before and after decontamination, samples underwent microbiological analysis by standard tissue bank methods. Cryopreserved samples were tested again with and without the removal of antibiotic residues using a RESEP tube, after thawing. Presence of antibiotics in tissue homogenates and processing liquids was determined by a modified agar diffusion test. All cryopreserved tissue homogenates and cryopreservation media induced important inhibition zones on both Staphylococcus aureus- and Pseudomonas aeruginosa-seeded plates, immediately after thawing and at the end of the sterility test. The RESEP tube treatment markedly reduced or totally eliminated the antimicrobial activity of tested tissues and media. Based on standard tissue bank analysis, 50% of tissues were found positive for bacteria and/or fungi, before decontamination and 2 out of 16 tested samples (13%) still contained microorganisms after decontamination. After thawing, none of the 16 cryopreserved samples resulted positive with direct inoculum method. When the same samples were tested after removal of antibiotic residues, 8 out of 16 (50%) were contaminated. Antibiotic residues present in tissue allografts and processing liquids after decontamination may mask microbial contamination during microbiological analysis performed with standard tissue bank methods, thus resulting in false negatives.

  20. Residual Antibiotics in Decontaminated Human Cardiovascular Tissues Intended for Transplantation and Risk of Falsely Negative Microbiological Analyses

    PubMed Central

    Gatto, Claudio; Manara, Sabrina; Dainese, Luca; Polvani, Gianluca; Tóthová, Jana D'Amato

    2014-01-01

    We investigated the presence of antibiotics in cryopreserved cardiovascular tissues and cryopreservation media, after tissue decontamination with antibiotic cocktails, and the impact of antibiotic residues on standard tissue bank microbiological analyses. Sixteen cardiovascular tissues were decontaminated with bank-prepared cocktails and cryopreserved by two different tissue banks according to their standard operating procedures. Before and after decontamination, samples underwent microbiological analysis by standard tissue bank methods. Cryopreserved samples were tested again with and without the removal of antibiotic residues using a RESEP tube, after thawing. Presence of antibiotics in tissue homogenates and processing liquids was determined by a modified agar diffusion test. All cryopreserved tissue homogenates and cryopreservation media induced important inhibition zones on both Staphylococcus aureus- and Pseudomonas aeruginosa-seeded plates, immediately after thawing and at the end of the sterility test. The RESEP tube treatment markedly reduced or totally eliminated the antimicrobial activity of tested tissues and media. Based on standard tissue bank analysis, 50% of tissues were found positive for bacteria and/or fungi, before decontamination and 2 out of 16 tested samples (13%) still contained microorganisms after decontamination. After thawing, none of the 16 cryopreserved samples resulted positive with direct inoculum method. When the same samples were tested after removal of antibiotic residues, 8 out of 16 (50%) were contaminated. Antibiotic residues present in tissue allografts and processing liquids after decontamination may mask microbial contamination during microbiological analysis performed with standard tissue bank methods, thus resulting in false negatives. PMID:25397402

  1. Developing a new diagnostic algorithm for human papilloma virus associated oropharyngeal carcinoma: an investigation of HPV DNA assays.

    PubMed

    Cohen, Natasha; Gupta, Michael; Doerwald-Munoz, Lilian; Jang, Dan; Young, James Edward Massey; Archibald, Stuart; Jackson, Bernard; Lee, Jenny; Chernesky, Max

    2017-02-13

    Human papilloma virus (HPV) has been implicated in the development of a large proportion of oropharyngeal squamous cell carcinoma (OPSCC). Current techniques used to diagnose HPV etiology require histopathologic analysis. We aim to investigate the diagnostic accuracy of a new application non-histopathologic diagnostic tests to help assist diagnosis of HPV-related oropharyngeal tumors. Patients with OPSCC with nodal metastasis were consecutively recruited from a multidisciplinary cancer clinic. Appropriate samples were collected and analyzed. The various tests examined included COBAS® 4800, Cervista® HR and Genotyping. These tests were compared to p16 staining, which was used as the diagnostic standard. StataIC 14.2 was used to perform analysis, including sensitivity, specificity and receiver operator characteristic [ROC] curves. The COBAS® FNA (area under ROC 0.863) and saliva (area under ROC 0.847) samples performed well in diagnosing HPV positive and negative tumors. Samples tested with Cervista® did not corroborate p16 status reliably. We were able to increase the diagnostic yield of the COBAS® FNA samples by applying the results of the saliva test to negative FNA samples which correctly identified 11 additional p16 positive tumors (area under ROC 0.915). Surrogate testing for HPV using alternate methods is feasible and closely predicts the results of standard diagnostic methods. In the future, these could minimize invasive procedures for diagnosing HPV-related oropharyngeal cancer, but also help to diagnose and treat patients with unknown primaries.

  2. [Detection of hepatitis c in blood donors in Niamey].

    PubMed

    Mamadou, S; Gragnic, G; Kabo, R; Salami, H; Boulkassoum, Z

    1997-01-01

    We searched for HCV antibodies in a random sample of 410 blood donors negative for HIV infection, hepatitis B and syphilis. 16 peoples were positive by ELISA and 13 by RIBA. So 3.2% of these donors negative for the three actual compulsory tests, are able to transmit HCV.

  3. Evaluation of a monoclonal antibody-based rapid immunochromatographic test for direct detection of rabies virus in the brain of humans and animals.

    PubMed

    Ahmed, Kamruddin; Wimalaratne, Omala; Dahal, Narapati; Khawplod, Pakamatz; Nanayakkara, Susilakanthi; Rinzin, Karma; Perera, Devika; Karunanayake, Dushantha; Matsumoto, Takashi; Nishizono, Akira

    2012-04-01

    Rabies diagnosis uses a direct fluorescent antibody test (FAT) that is difficult, costly, and time-consuming, and requires trained personnel. We developed a rapid immunochromatographic test (RICT) for the diagnosis of rabies. The efficacy of the RICT was compared with that of the FAT. Brain samples were collected from humans, dogs, cats, and other animals in Sri Lanka (n = 248), Bhutan (n = 27), and Thailand (n = 228). The sensitivity (0.74-0.95), specificity (0.98-1.0), positive predictive value (0.98-1.0), negative predictive value (0.75-0.97), accuracy (0.91-0.98), and kappa measure of agreement (0.79-0.93) were all satisfactory for animal samples and samples preserved in 50% glycerol saline solution. Because the RICT showed high sensitivity but low specificity with human brain samples, it is unsuitable for confirming rabies in humans. No amino acid substitutions were found in the antibody attachment sites of the nucleoprotein gene with FAT-positive, RICT-negative samples. The RICT is reliable, user friendly, rapid, robust, and can be used in laboratories with a modest infrastructure.

  4. Sample size for positive and negative predictive value in diagnostic research using case–control designs

    PubMed Central

    Steinberg, David M.; Fine, Jason; Chappell, Rick

    2009-01-01

    Important properties of diagnostic methods are their sensitivity, specificity, and positive and negative predictive values (PPV and NPV). These methods are typically assessed via case–control samples, which include one cohort of cases known to have the disease and a second control cohort of disease-free subjects. Such studies give direct estimates of sensitivity and specificity but only indirect estimates of PPV and NPV, which also depend on the disease prevalence in the tested population. The motivating example arises in assay testing, where usage is contemplated in populations with known prevalences. Further instances include biomarker development, where subjects are selected from a population with known prevalence and assessment of PPV and NPV is crucial, and the assessment of diagnostic imaging procedures for rare diseases, where case–control studies may be the only feasible designs. We develop formulas for optimal allocation of the sample between the case and control cohorts and for computing sample size when the goal of the study is to prove that the test procedure exceeds pre-stated bounds for PPV and/or NPV. Surprisingly, the optimal sampling schemes for many purposes are highly unbalanced, even when information is desired on both PPV and NPV. PMID:18556677

  5. Statistical analysis of biomechanical properties of the adult skull and age-related structural changes by sex in a Japanese forensic sample.

    PubMed

    Torimitsu, Suguru; Nishida, Yoshifumi; Takano, Tachio; Koizumi, Yoshinori; Makino, Yohsuke; Yajima, Daisuke; Hayakawa, Mutsumi; Inokuchi, Go; Motomura, Ayumi; Chiba, Fumiko; Otsuka, Katsura; Kobayashi, Kazuhiro; Odo, Yuriko; Iwase, Hirotaro

    2014-01-01

    The purpose of this research was to investigate the biomechanical properties of the adult human skull and the structural changes that occur with age in both sexes. The heads of 94 Japanese cadavers (54 male cadavers, 40 female cadavers) autopsied in our department were used in this research. A total of 376 cranial samples, four from each skull, were collected. Sample fracture load was measured by a bending test. A statistically significant negative correlation between the sample fracture load and cadaver age was found. This indicates that the stiffness of cranial bones in Japanese individuals decreases with age, and the risk of skull fracture thus probably increases with age. Prior to the bending test, the sample mass, the sample thickness, the ratio of the sample thickness to cadaver stature (ST/CS), and the sample density were measured and calculated. Significant negative correlations between cadaver age and sample thickness, ST/CS, and the sample density were observed only among the female samples. Computerized tomographic (CT) images of 358 cranial samples were available. The computed tomography value (CT value) of cancellous bone which refers to a quantitative scale for describing radiodensity, cancellous bone thickness and cortical bone thickness were measured and calculated. Significant negative correlation between cadaver age and the CT value or cortical bone thickness was observed only among the female samples. These findings suggest that the skull is substantially affected by decreased bone metabolism resulting from osteoporosis. Therefore, osteoporosis prevention and treatment may increase cranial stiffness and reinforce the skull structure, leading to a decrease in the risk of skull fractures. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  6. Molecular screening for hemotropic mycoplasmas in captive Barbary sheep (Ammotragus lervia) in southern Brazil.

    PubMed

    Santos, Leonilda C; Vidotto, Odilon; Morikawa, Vivien M; Santos, Nelson J R; Vieira, Thállitha S W J; Barros Filho, Ivan R; Vieira, Rafael F C; Biondo, Alexander W

    2017-08-01

    This study is part of an active surveillance program for monitoring animal health status in endangered species, and was conducted to screen captive Barbary sheep ( Ammotragus lervia ) for hemoplasma infection. A total of 12 blood samples were collected, DNA extracted and further tested by a pan-hemoplasma polymerase chain reaction protocol. Animals were clinically healthy and not infested by ectoparasites. Although housekeeping gene DNA was successfully amplified, all the Barbary sheep samples tested negative for Mycoplasma sp. Notwithstanding the negative results, molecular pathogen surveys on Barbary sheep and other exotic wild mammals may provide insights regarding infection of endangered species caused by captivity stress in association with exposure to new pathogens worldwide.

  7. Unreliable alcohol testing in a shipping safety programme.

    PubMed

    Helander, Anders; Hagelberg, Charlotte Asker; Beck, Olof; Petrini, Björn

    2009-08-10

    Within a maritime alcohol and drug testing programme, a case showing an unphysiological urine ethanol concentration (235 mmol/L, 10.8 g/L) was found. The sample contained low levels of the ethanol metabolites ethyl glucuronide (EtG) and ethyl sulphate (EtS) which confirmed prior drinking, but also tested positive for the fermenting yeast Candida albicans which suggested post-sampling ethanol formation. This and other questionable cases prompted investigation of the suitability of urine alcohol testing for the intended application. Besides the routine measurements of ethanol, illicit drugs and creatinine, randomly selected ethanol-positive and ethanol-negative urines collected within the maritime programme were checked for the presence of EtG and EtS and for fungal and bacterial growth. Data on sample handling and storage was also gathered. Ten of 15 (67%) ethanol-positive and 4 of 9 (44%) ethanol-negative urines contained yeast and/or bacteria. Among the ethanol-positive cases, 4 (27%) were obviously false positives because EtG and EtS were not detected. Microbial action as the reason for false-high ethanol concentrations was indicated in other cases. When 17 bacteria-infected but fungi-negative urines were supplemented with glucose and stored for 1 week at 21 degrees C, ethanol was formed in 2 specimens containing Escherichia coli and E. coli plus P. aeruginosa. In these samples, EtG was also formed on storage while EtS was not. The routines employed for urine collection and handling within this substance abuse programme caused many false-positive identifications of alcohol use with unintended medico-legal consequences. Unpreserved urines stored without cooling should not be used for alcohol testing, given the high risk for microbial interference.

  8. Comparison of a standardized procedure with current laboratory practices for the detection of lupus anticoagulant in France. Working Group on Hemostasis of the Société Française de Biologie Clinique.

    PubMed

    1993-11-15

    A multicenter study involving 13 laboratories was designed to compare a common procedure for screening lupus anticoagulants (LA) to the different practices currently in use in these laboratories. The common procedure combined 3 phospholipid-dependent assays, including mixing studies and a phospholipid neutralizing test. Due to the heterogeneity of LA expression, an abnormal result in at least one of the tests was sufficient to classify a sample as positive for LA. Consecutive samples referred for LA diagnosis were evaluated in parallel by each participant and the data found using the common procedure were analyzed independently according to mutually agreed cut-offs and criteria for sample classification. Within a period of 3 months, 535 samples were included, of which 147 were judged LA positive, 29 undetermined and 359 negative by the respective laboratories using their current practice. When using the common procedure, 149 plasmas were said to be positive, 38 undetermined and 348 negative. Absolute concordance occurred for 81% of the specimen population and absolute discordance (positive versus negative) for 7%. The level of agreement between the common procedure and the current practices, assessed by kappa indexes, indicated noticeable variations in the rates of detection from laboratory to laboratory. Among the different tests used in the common procedure, regular APTT was the least sensitive (about 50% detection) but none of the other tests alone recognized more than 73% of specimens from the LA positive population. This yield increased to about 90% with any combination of 2 sensitive tests.(ABSTRACT TRUNCATED AT 250 WORDS)

  9. Recruiting a U.S. national sample of HIV-negative gay and bisexual men to complete at-home self-administered HIV/STI testing and surveys: Challenges and Opportunities

    PubMed Central

    Grov, Christian; Cain, Demetria; Whitfield, Thomas H. F.; Rendina, H. Jonathon; Pawson, Mark; Ventuneac, Ana; Parsons, Jeffrey T.

    2015-01-01

    We describe enrollment for the One Thousand Strong panel, present characteristics of the panel relative to other large U.S. national studies of gay and bisexual men (GBM), and examine demographic and behavioral characteristics that were associated with passing enrollment milestones. A U.S. national sample of HIV-negative men were enrolled via an established online panel of over 22,000 GBM. Participants (n = 1071) passed three milestones to join our panel. Milestone 1 was screening eligible and providing informed consent. Milestone 2 involved completing an hour-long at-home computer-assisted self-interview (CASI) survey. Milestone 3 involved completing at-home self-administered rapid HIV testing and collecting/returning urine and rectal samples for gonorrhea and chlamydia testing. Compared to those who completed milestones: those not passing milestone 1 were more likely to be non-White and older; those not passing milestone 2 were less likely to have insurance or a primary care physician; and those not passing milestone 3 were less educated, more likely to be bisexual as opposed to gay, more likely to live in the Midwest, had fewer male partners in the past year, and less likely to have tested for HIV in the past year. Effect sizes for significant findings were small. We successfully enrolled a national sample of HIV-negative GBM who completed at-home CASI assessments and at-home self-administered HIV and urine and rectal STI testing. This indicates high feasibility and acceptability of incorporating self-administered biological assays into otherwise fully online studies. Differences in completion of study milestones indicate a need for further investigation into the reasons for lower engagement by certain groups. PMID:26858776

  10. ALK status testing in non-small cell lung carcinoma: correlation between ultrasensitive IHC and FISH.

    PubMed

    Minca, Eugen C; Portier, Bryce P; Wang, Zhen; Lanigan, Christopher; Farver, Carol F; Feng, Yan; Ma, Patrick C; Arrossi, Valeria A; Pennell, Nathan A; Tubbs, Raymond R

    2013-05-01

    ALK gene rearrangements in advanced non-small cell lung carcinomas (NSCLC) are an indication for targeted therapy with crizotinib. Fluorescence in situ hybridization (FISH) using a recently approved companion in vitro diagnostic class FISH system commonly assesses ALK status. More accessible IHC is challenged by low expression of ALK-fusion transcripts in NSCLC. We compared ultrasensitive automated IHC with FISH for detecting ALK status on 318 FFPE and 40 matched ThinPrep specimens from 296 patients with advanced NSCLC. IHC was concordant with FFPE-FISH on 229 of 231 dual-informative samples (31 positive and 198 negative) and with ThinPrep-FISH on 34 of 34 samples (5 positive and 29 negative). Two cases with negative IHC and borderline-positive FFPE-FISH (15% and 18%, respectively) were reclassified as concordant based on negative matched ThinPrep-FISH and clinical data consistent with ALK-negative status. Overall, after including ThinPrep-FISH and amending the false-positive FFPE-FISH results, IHC demonstrated 100% sensitivity and specificity (95% CI, 0.86 to 1.00 and 0.97 to 1.00, respectively) for ALK detection on 249 dual-informative NSCLC samples. IHC was informative on significantly more samples than FFPE-FISH, revealing additional ALK-positive cases. The high concordance with FISH warrants IHC's routine use as the initial component of an algorithmic approach to clinical ALK testing in NSCLC, followed by reflex FISH confirmation of IHC-positive cases. Copyright © 2013 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  11. The Test Validation Summary

    ERIC Educational Resources Information Center

    Frederick, Richard I.; Bowden, Stephen C.

    2009-01-01

    Common rates employed in classificatory testing are the true positive rate (TPR), false positive rate (FPR), positive predictive power (PPP), and negative predictive power (NPP). FPR and TPR are estimated from research samples representing populations to be distinguished by classificatory testing. PPP and NPP are used by clinicians to classify…

  12. Screening for Babesia microti in the U.S. Blood Supply.

    PubMed

    Moritz, Erin D; Winton, Colleen S; Tonnetti, Laura; Townsend, Rebecca L; Berardi, Victor P; Hewins, Mary-Ellen; Weeks, Karen E; Dodd, Roger Y; Stramer, Susan L

    2016-12-08

    Babesia microti, a tickborne intraerythrocytic parasite that can be transmitted by means of blood transfusion, is responsible for the majority of cases of transfusion-transmitted babesiosis in the United States. However, no licensed test exists for screening for B. microti in donated blood. We assessed data from a large-scale, investigational product-release screening and donor follow-up program. From June 2012 through September 2014, we performed arrayed fluorescence immunoassays (AFIAs) for B. microti antibodies and real-time polymerase-chain-reaction (PCR) assays for B. microti DNA on blood-donation samples obtained in Connecticut, Massachusetts, Minnesota, and Wisconsin. We determined parasite loads with the use of quantitative PCR testing and assessed infectivity by means of the inoculation of hamsters and the subsequent examination for parasitemia. Donors with test-reactive samples were followed. Using data on cases of transfusion-transmitted babesiosis, we compared the proportions of screened versus unscreened donations that were infectious. Of 89,153 blood-donation samples tested, 335 (0.38%) were confirmed to be positive, of which 67 (20%) were PCR-positive; 9 samples were antibody-negative (i.e., 1 antibody-negative sample per 9906 screened samples), representing 13% of all PCR-positive samples. PCR-positive samples were identified all through the year; antibody-negative infections occurred from June through September. Approximately one third of the red-cell samples from PCR-positive or high-titer AFIA-positive donations infected hamsters. Follow-up showed DNA clearance in 86% of the donors but antibody seroreversion in 8% after 1 year. In Connecticut and Massachusetts, no reported cases of transfusion-transmitted babesiosis were associated with screened donations (i.e., 0 cases per 75,331 screened donations), as compared with 14 cases per 253,031 unscreened donations (i.e., 1 case per 18,074 unscreened donations) (odds ratio, 8.6; 95% confidence interval, 0.51 to 144; P=0.05). Overall, 29 cases of transfusion-transmitted babesiosis were linked to blood from infected donors, including blood obtained from 10 donors whose samples tested positive on the PCR assay 2 to 7 months after the implicated donation. Blood-donation screening for antibodies to and DNA from B. microti was associated with a decrease in the risk of transfusion-transmitted babesiosis. (Funded by the American Red Cross and Imugen; ClinicalTrials.gov number, NCT01528449 .).

  13. Positive affect and psychosocial processes related to health.

    PubMed

    Steptoe, Andrew; O'Donnell, Katie; Marmot, Michael; Wardle, Jane

    2008-05-01

    Positive affect is associated with longevity and favourable physiological function. We tested the hypothesis that positive affect is related to health-protective psychosocial characteristics independently of negative affect and socio-economic status. Both positive and negative affect were measured by aggregating momentary samples collected repeatedly over 1 day, and health-related psychosocial factors were assessed by questionnaire in a sample of 716 men and women aged 58-72 years. Positive affect was associated with greater social connectedness, emotional and practical support, optimism and adaptive coping responses, and lower depression, independently of age, gender, household income, paid employment, smoking status, and negative affect. Negative affect was independently associated with negative relationships, greater exposure to chronic stress, depressed mood, pessimism, and avoidant coping. Positive affect may be beneficial for health outcomes in part because it is a component of a profile of protective psychosocial characteristics.

  14. Development and verification of a model for estimating the screening utility in the detection of PCBs in transformer oil.

    PubMed

    Terakado, Shingo; Glass, Thomas R; Sasaki, Kazuhiro; Ohmura, Naoya

    2014-01-01

    A simple new model for estimating the screening performance (false positive and false negative rates) of a given test for a specific sample population is presented. The model is shown to give good results on a test population, and is used to estimate the performance on a sampled population. Using the model developed in conjunction with regulatory requirements and the relative costs of the confirmatory and screening tests allows evaluation of the screening test's utility in terms of cost savings. Testers can use the methods developed to estimate the utility of a screening program using available screening tests with their own sample populations.

  15. Estimates of 2012/13 influenza vaccine effectiveness using the case test-negative control design with different influenza negative control groups.

    PubMed

    Nunes, Baltazar; Machado, Ausenda; Guiomar, Raquel; Pechirra, Pedro; Conde, Patrícia; Cristovão, Paula; Falcão, Isabel

    2014-07-31

    In recent years several reports of influenza vaccine effectiveness (VE) have been made early for public health decision. The majority of these studies use the case test-negative control design (TND), which has been showed to provide, under certain conditions, unbiased estimates of influenza VE. Nevertheless, discussions have been taken on the best influenza negative control group to use. The present study aims to contribute to the knowledge on this field by comparing influenza VE estimates using three test-negative controls: all influenza negative, non-influenza respiratory virus and pan-negative. Incident ILI patients were prospectively selected and swabbed by a sample of general practitioners. Cases were ILI patients tested positive for influenza and controls ILI patients tested negative for influenza. The influenza negative control group was divided into non-influenza virus control group and pan-negative control group. Data were collected on vaccination status and confounding factors. Influenza VE was estimated as one minus the odds ratio of been vaccinated in cases versus controls adjusted for confounding effect by logistic regression. Confounder adjusted influenza VE against medically attended laboratory-confirmed influenza was 68.4% (95% CI: 20.7-87.4%) using all influenza negatives controls, 82.1% (95% CI: 47.6-93.9%) using non-influenza controls and 49.4% (95% CI: -44.7% to 82.3%) using pan-negative controls. Influenza VE estimates differed according to the influenza negative control group used. These results are in accordance with the expected under the hypothesis of differential viral interference between influenza vaccinated and unvaccinated individuals. Given the wide importance of TND study further studies should be conducted in order to clarify the observed differences. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Evaluation of the rapid diagnostic test CareStart pLDH Malaria (Pf-pLDH/pan-pLDH) for the diagnosis of malaria in a reference setting.

    PubMed

    Heutmekers, Marloes; Gillet, Philippe; Maltha, Jessica; Scheirlinck, Annelies; Cnops, Lieselotte; Bottieau, Emmanuel; Van Esbroeck, Marjan; Jacobs, Jan

    2012-06-18

    The present study evaluated CareStart pLDH Malaria, a three-band rapid diagnostic test detecting Plasmodium falciparum-specific parasite lactate dehydrogenase (Pf-pLDH) and pan Plasmodium-specific pLDH (pan-pLDH) in a reference setting. CareStart pLDH was retrospectively and prospectively assessed with a panel of stored (n=498) and fresh (n=77) blood samples obtained in international travelers suspected of malaria. Both panels comprised all four Plasmodium species; the retrospective panel comprised also Plasmodium negative samples. The reference method was microscopy corrected by PCR. The prospective panel was run side-to-side with OptiMAL (Pf-pLDH/pan-pLDH) and SDFK60 (histidine-rich protein-2 (HRP-2)/pan-pLDH). In the retrospective evaluation, overall sensitivity for P. falciparum samples (n=247) was 94.7%, reaching 98.7% for parasite densities>1,000/μl. Most false negative results occurred among samples with pure gametocytaemia (2/12, 16.7%) and at parasite densities ≤ 100/μl (7/12, 58.3%). None of the Plasmodium negative samples (n=96) showed visible test lines. Sensitivities for Plasmodium vivax (n=70), Plasmodium ovale (n=69) and Plasmodium malariae (n=16) were 74.3%, 31.9% and 25.0% respectively. Wrong species identification occurred in 10 (2.5%) samples and was mainly due to P. vivax samples reacting with the Pf-pLDH test line. Overall, Pf-pLDH test lines showed higher line intensities compared to the pan-pLDH lines (67.9% and 23.0% medium and strong line intensities for P. falciparum). In the prospective panel (77 Plasmodium-positive samples), CareStart pLDH showed higher sensitivities for P. falciparum compared to OptiMAL (p=0.008), lower sensitivities for P. falciparum as compare to SDFK60 (although not reaching statistical significance, p=0.08) and higher sensitivities for P. ovale compared to both OptiMAL (p=0.03) and SDFK60 (p=0.01). Inter-observer and test reproducibility were good to excellent. CareStart pLDH performed excellent for the detection of P. falciparum, well for P. vivax, but poor for P. ovale and P. malariae.

  17. Field assessment of dried Plasmodium falciparum samples for malaria rapid diagnostic test quality control and proficiency testing in Ethiopia.

    PubMed

    Tamiru, Afework; Boulanger, Lucy; Chang, Michelle A; Malone, Joseph L; Aidoo, Michael

    2015-01-21

    Rapid diagnostic tests (RDTs) are now widely used for laboratory confirmation of suspected malaria cases to comply with the World Health Organization recommendation for universal testing before treatment. However, many malaria programmes lack quality control (QC) processes to assess RDT use under field conditions. Prior research showed the feasibility of using the dried tube specimen (DTS) method for preserving Plasmodium falciparum parasites for use as QC samples for RDTs. This study focused on the use of DTS for RDT QC and proficiency testing under field conditions. DTS were prepared using cultured P. falciparum at densities of 500 and 1,000 parasites/μL; 50 μL aliquots of these along with parasite negative human blood controls (0 parasites/μL) were air-dried in specimen tubes and reactivity verified after rehydration. The DTS were used in a field study in the Oromia Region of Ethiopia. Replicate DTS samples containing 0, 500 and 1,000 parasites/μL were stored at 4°C at a reference laboratory and at ambient temperatures at two nearby health facilities. At weeks 0, 4, 8, 12, 16, 20, and 24, the DTS were rehydrated and tested on RDTs stored under manufacturer-recommended temperatures at the RL and on RDTs stored under site-specific conditions at the two health facilities. Reactivity of DTS stored at 4°C at the reference laboratory on RDTs stored at the reference laboratory was considered the gold standard for assessing DTS stability. A proficiency-testing panel consisting of one negative and three positive samples, monitored with a checklist was administered at weeks 12 and 24. At all the seven time points, DTS stored at both the reference laboratory and health facility were reactive on RDTs stored under the recommended temperature and under field conditions, and the DTS without malaria parasites were negative. At the reference laboratory and one health facility, a 500 parasites/μL DTS from the proficiency panel was falsely reported as negative at week 24 due to errors in interpreting faint test lines. The DTS method can be used under field conditions to supplement other RDT QC methods and health worker proficiency in Ethiopia and possibly other malaria-endemic countries.

  18. Chlamydiae in the ejaculate: their influence on the quality and morphology of sperm.

    PubMed

    Veznik, Zdenek; Pospisil, Leopold; Svecova, Drahomira; Zajicova, Atanaska; Unzeitig, Vit

    2004-07-01

    Given the lack of information concerning the role of Chlamydia trachomatis in male fertility, the aim of this study was to ascertain and analyze the quality of Chlamydiae-positive and -negative semen. Sperm count was performed according to the 1999 World Health Organization (WHO) laboratory manual for examination of human semen and sperm-cervical mucus interaction, and sperm survival was assessed by a 120-min test. The evaluation of the morphological examination of ejaculates was carried out using the sasmo (strict morphological analysis of ejaculates) computer program. Chlamydiae were detected by immunofluorescent reaction using the Progen Biotechnik GmbH diagnostic set. Fisher's exact test and the chi-quadrate test were used for statistical analysis. Of the total of 627 sperm samples examined, Chlamydiae were detected in 136 cases (21.7%). Sperm analysis showed significant differences between Chlamydiae-positive and -negative samples. The Chlamydiae-contaminated group showed normal sperm morphology 14.4% lower, volume 6.4% lower, concentration 8.3% lower, motility 7.8% and velocity 9.3% lower than in Chlamydiae-negative samples. The average values for normal spermatozoa and motility in the Chlamydiae-positive group were also significantly reduced. Chlamydia trachomatis was found to be a possible factor in sperm pathology. These results could help to elucidate the role of Chlamydia trachomatis in male infertility.

  19. Middle East respiratory syndrome coronavirus antibody reactors among camels in Dubai, United Arab Emirates, in 2005.

    PubMed

    Alexandersen, S; Kobinger, G P; Soule, G; Wernery, U

    2014-04-01

    We tested, using a low starting dilution, sequential serum samples from dromedary camels, sheep and horses collected in Dubai from February/April to October of 2005 and from dromedary camels for export/import testing between Canada and USA in 2000-2001. Using a standard Middle East respiratory syndrome coronavirus (MERS-CoV) neutralization test, serial sera from three sheep and three horses were all negative while sera from 9 of 11 dromedary camels from Dubai were positive for antibodies supported by similar results in a MERS-CoV recombinant partial spike protein antibody ELISA. The two negative Dubai camels were both dromedary calves and remained negative over the 5 months studied. The six dromedary samples from USA and Canada were negative in both tests. These results support the recent findings that infection with MERS-CoV or a closely related virus is not a new occurrence in camels in the Middle East. Therefore, interactions of MERS-CoV at the human-animal interface may have been ongoing for several, perhaps many, years and by inference, a widespread pandemic may be less likely unless significant evolution of the virus allow accelerated infection and spread potential in the human population. © Her Majesty the Queen in Right of Canada 2014 Reproduced with the permission of the Minister of Agriculture and Agri-food and Minister of Health.

  20. Latent profile analysis of regression-based norms demonstrates relationship of compounding MS symptom burden and negative work events.

    PubMed

    Frndak, Seth E; Smerbeck, Audrey M; Irwin, Lauren N; Drake, Allison S; Kordovski, Victoria M; Kunker, Katrina A; Khan, Anjum L; Benedict, Ralph H B

    2016-10-01

    We endeavored to clarify how distinct co-occurring symptoms relate to the presence of negative work events in employed multiple sclerosis (MS) patients. Latent profile analysis (LPA) was utilized to elucidate common disability patterns by isolating patient subpopulations. Samples of 272 employed MS patients and 209 healthy controls (HC) were administered neuroperformance tests of ambulation, hand dexterity, processing speed, and memory. Regression-based norms were created from the HC sample. LPA identified latent profiles using the regression-based z-scores. Finally, multinomial logistic regression tested for negative work event differences among the latent profiles. Four profiles were identified via LPA: a common profile (55%) characterized by slightly below average performance in all domains, a broadly low-performing profile (18%), a poor motor abilities profile with average cognition (17%), and a generally high-functioning profile (9%). Multinomial regression analysis revealed that the uniformly low-performing profile demonstrated a higher likelihood of reported negative work events. Employed MS patients with co-occurring motor, memory and processing speed impairments were most likely to report a negative work event, classifying them as uniquely at risk for job loss.

  1. The associations between adult attachment, posttraumatic symptoms, and posttraumatic growth.

    PubMed

    Arikan, Gizem; Stopa, Lusia; Carnelley, Katherine B; Karl, Anke

    2016-01-01

    Individual differences after trauma vary considerably and can range from posttraumatic stress disorder (PTSD) to posttraumatic growth (PTG). Current theoretical models cannot fully explain this variability. Therefore, we integrated attachment theory with Ehlers and Clark's model of PTSD to understand whether attachment style is associated with negative appraisals of a traumatic event(s), posttraumatic stress symptoms (PTS), and PTG. Our aim was to test this integrated model PTSD in an analog sample who had experienced at least one traumatic event. We used structural equation modeling to test the association of adult attachment and posttraumatic cognitions (self and world/others) with PTS and PTG using a cross-sectional, correlational design. The sample comprised 393 university staff and students (RangeAge= 18-49, 85% females) who completed online measures. Attachment anxiety and negative posttraumatic self-cognitions were positively associated. Negative posttraumatic self-cognitions were positively associated with PTS. Attachment anxiety had an indirect effect (via negative posttraumatic self-cognitions) on PTS, whereas attachment avoidance predicted more negative posttraumatic world cognitions and lower perceived PTG. The study highlights the importance of considering how attachment styles influence posttraumatic emotion regulation and cognitive processing of the trauma to determine posttraumatic mental health.

  2. Recent sequence variation in probe binding site affected detection of respiratory syncytial virus group B by real-time RT-PCR.

    PubMed

    Kamau, Everlyn; Agoti, Charles N; Lewa, Clement S; Oketch, John; Owor, Betty E; Otieno, Grieven P; Bett, Anne; Cane, Patricia A; Nokes, D James

    2017-03-01

    Direct immuno-fluorescence test (IFAT) and multiplex real-time RT-PCR have been central to RSV diagnosis in Kilifi, Kenya. Recently, these two methods showed discrepancies with an increasing number of PCR undetectable RSV-B viruses. Establish if mismatches in the primer and probe binding sites could have reduced real-time RT-PCR sensitivity. Nucleoprotein (N) and glycoprotein (G) genes were sequenced for real-time RT-PCR positive and negative samples. Primer and probe binding regions in N gene were checked for mismatches and phylogenetic analyses done to determine molecular epidemiology of these viruses. New primers and probe were designed and tested on the previously real-time RT-PCR negative samples. N gene sequences revealed 3 different mismatches in the probe target site of PCR negative, IFAT positive viruses. The primers target sites had no mismatches. Phylogenetic analysis of N and G genes showed that real-time RT-PCR positive and negative samples fell into distinct clades. Newly designed primers-probe pair improved detection and recovered previous PCR undetectable viruses. An emerging RSV-B variant is undetectable by a quite widely used real-time RT-PCR assay due to polymorphisms that influence probe hybridization affecting PCR accuracy. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  3. Diagnostic utility of a line probe assay for multidrug resistant-TB in smear-negative pulmonary tuberculosis.

    PubMed

    Singh, Binit Kumar; Sharma, Surendra K; Sharma, Rohini; Sreenivas, Vishnubhatla; Myneedu, Vithal P; Kohli, Mikashmi; Bhasin, Dinkar; Sarin, Sanjay

    2017-01-01

    To evaluate the performance of Genotype MTBDRplus VER 2.0 in the diagnosis of Mycobacterium tuberculosis (MTB) in sputum smear-negative pulmonary TB cases. A total of 572 Ziehl-Neelsen sputum smear-negative samples were selected and subjected to line probe assay (Genotype MTBDRplus VER 2.0), and culture in mycobacterial growth indicator tube (MGIT-960). Immunochromatographic test was used to confirm the MTB-complex (MTBC) in culture-positive samples and phenotypic drug-susceptibility testing was done using MGIT-960. The line probe assay was able to diagnose MTBC in 38.2% (213/558) of specimens after excluding 14 nontuberculous mycobacteria. Sensitivity and specificity of the assay were 68.4% and 89.3% respectively, considering MGIT-960 culture as gold standard after excluding contaminated and invalid results. On comparing with composite reference standard, the assay had 71.5% sensitivity and 100% specificity in the diagnosis of tuberculosis. The sensitivity and specificity for detecting resistance to rifampicin (RMP) were 100% and 99.24% respectively and for resistance to isoniazid (INH) were 97.62% and 98.55%, respectively. Genotype MTBDRplus VER 2.0 is a rapid and precise diagnostic tool for detection of MTB in sputum smear-negative samples. It also facilitates accurate diagnosis of RMP and INH resistance within turn around-time.

  4. MPL mutation profile in JAK2 mutation-negative patients with myeloproliferative disorders.

    PubMed

    Ma, Wanlong; Zhang, Xi; Wang, Xiuqiang; Zhang, Zhong; Yeh, Chen-Hsiung; Uyeji, Jennifer; Albitar, Maher

    2011-03-01

    Mutations in the thrombopoietin receptor gene (myeloproliferative leukemia, MPL) have been reported in patients with JAK2 V617F-negative chronic myeloproliferative disorders (MPDs). We evaluated the prevalence of MPL mutations relative to JAK2 mutations in patients with suspected MPDs. A total of 2790 patient samples submitted for JAK2 mutation analysis were tested using real-time polymerase chain reaction and bidirectional sequencing of plasma RNA. JAK2 V617F-negative samples were tested for JAK2 exons 12 to 14 mutations, and those with negative results were then tested for mutations in MPL exons 10 and 11. Of the 2790 patients, 529 (18.96%) had V617F, 12 (0.43%) had small insertions or deletions in exon 12, and 7 (0.25%) had other JAK2 mutations in exons 12 to 14. Of the 2242 JAK2 mutation-negative patients, 68 (3.03%) had MPL mutations. W515L was the predominant MPL mutation (n=46; 68%), and 10 (15%) patients had other W515 variants. The remaining MPL mutations (n=12, 17%) were detected at other locations in exons 10 and 11 and included 3 insertion/deletion mutations. The S505N mutation, associated with familial MPD, was detected in 3 patients. Overall, for every 100 V617F mutations in patients with suspected MPDs, there were 12.9 MPL mutations, 2.3 JAK2 exon 12 mutations, and 1.3 JAK2 exons 13 to 14 mutations. These findings suggest that MPL mutation screening should be performed before JAK2 exons 12 to 14 testing in JAK2 V617F-negative patients with suspected MPDs.

  5. Evaluation of enzyme-linked immunosorbent assays performed on milk and serum samples for detection of neosporosis and leukosis in lactating dairy cows

    PubMed Central

    Walsh, Robert B.; Kelton, David F.; Hietala, Sharon K.; Duffield, Todd F.

    2013-01-01

    Serum and milk samples from 1229 cows on 22 Ontario dairy farms were individually tested for antibodies specific for bovine leukosis virus (BLV) and Neospora caninum by enzyme-linked immunosorbent assay (ELISA). Antibodies against BLV were present in 361 serum samples (29.4%) and 369 milk samples (30.0%). Comparing the 2 tests, agreement was almost perfect (k = 0.86; 95% CI = 0.83 to 0.90) and the proportions of samples positive were not significantly different (P = 0.56). Both tests identified the same 3 herds free of bovine leukosis virus. Antibodies against N. caninum were detected in 138 serum samples (11.2%), and 111 milk samples (9.0%). Agreement between the 2 tests was moderate (k = 0.52; 95% CI = 0.43 to 0.59). Four herds were free of neosporosis by the serum test, while 10 herds were negative by the milk test. The ELISA on milk samples facilitates sample collection to classify herds free of BLV; the milk N. caninum ELISA was less reliable in predicting herd-level infection. PMID:24082160

  6. Evaluation of Sanofi Diagnostics Pasteur Chlamydia Microplate EIA shortened assay and comparison with cell culture and Syva Chlamydia MicroTrak II EIA in high- and low-risk populations.

    PubMed

    Chan, E L; Brandt, K; Horsman, G

    1995-11-01

    Seven hundred thirty-two female urogenital samples were collected for Chlamydia trachomatis testing by both the Sanofi Diagnostics Pasteur (Chaska, Minn.) Chlamydia Microplate EIA by the shortened protocol and the Syva (San Jose, Calif.) MicroTrak II EIA, and the results were compared with those obtained by cell culture. For the analysis of samples from female patients, the patients were divided into high- and low-risk categories. An additional 121 male urethral samples were collected and tested by the Sanofi Microplate EIA and cell culture; for the analysis of samples from male patients, the patients were divided into asymptomatic and symptomatic categories. All specimens positive by enzyme immunoassay (EIA) were confirmed by a blocking assay following the respective manufacturer's instructions. Specimens negative by EIA that fell within a gray zone 30% below the cutoff and negative cultures with one or more corresponding positive EIA results were tested further by cytocentrifugation and direct immunofluorescent assay. The overall sensitivity, specificity, positive predictive value, and negative predictive value for Syva versus culture were 94, 98.8, 85.5 and 99.6%, respectively. After resolution, the results were 94.5, 99.6, 94.5, and 99.6%, respectively. The parallel results for the Sanofi Microplate EIA versus culture were 94.0, 98.7, and 83.9, and 99.6%, respectively, and after being resolved, the results were 94.9, 100, 100, and 99.6%, respectively. In the small male population tested, the resolved results of the Sanofi Microplate EIA versus culture demonstrated sensitivity, specificity, positive predictive value, and negative predictive value of 100, 100, 100, and 100%, respectively. The present study demonstrated that the Sanofi Microplate EIA shortened protocol is highly sensitive and specific in comparison with cell culture and the Syva MicroTrak II EIA.

  7. Estimating the Burden of Leptospirosis among Febrile Subjects Aged below 20 Years in Kampong Cham Communities, Cambodia, 2007-2009

    PubMed Central

    Hem, Sopheak; Ly, Sowath; Votsi, Irene; Vogt, Florian; Asgari, Nima; Buchy, Philippe; Heng, Seiha; Picardeau, Mathieu; Sok, Touch; Ly, Sovann; Huy, Rekol; Guillard, Bertrand; Cauchemez, Simon; Tarantola, Arnaud

    2016-01-01

    Background Leptospirosis is an emerging but neglected public health challenge in the Asia/Pacific Region with an annual incidence estimated at 10–100 per 100,000 population. No accurate data, however, are available for at-risk rural Cambodian communities. Method We conducted anonymous, unlinked testing for IgM antibodies to Leptospira spp. on paired sera of Cambodian patients <20 years of age between 2007–2009 collected through active, community-based surveillance for febrile illnesses in a convenience sample of 27 rural and semi-rural villages in four districts of Kampong Cham province, Cambodia. Leptospirosis testing was done on paired serological samples negative for Dengue, Japanese encephalitis and Chikungunya viruses after random selection. Convalescent samples found positive while initial samples were negative were considered as proof of acute infection. We then applied a mathematical model to estimate the risk of fever caused by leptospirosis, dengue or other causes in rural Cambodia. Results A total of 630 samples are coming from a randomly selected subset of 2358 samples. IgM positive were found on the convalescent serum sample, among which 100 (15.8%) samples were IgM negative on an earlier sample. Seventeen of these 100 seroconversions were confirmed using a Microagglutination Test. We estimated the probability of having a fever due to leptospirosis at 1. 03% (95% Credible Interval CI: 0. 95%–1. 22%) per semester. In comparison, this probability was 2. 61% (95% CI: 2. 55%, 2. 83%) for dengue and 17. 65% (95% CI: 17. 49%, 18. 08%) for other causes. Conclusion Our data from febrile cases aged below 20 years suggest that the burden of leptospirosis is high in rural Cambodian communities. This is especially true during the rainy season, even in the absence of identified epidemics. PMID:27043016

  8. Bloodstains on Leather: Examination of False Negatives in Presumptive Test and Human Hemoglobin Test.

    PubMed

    Castelló, Ana; Francès, Francesc; Verdú, Fernando

    2017-09-01

    Presumptive tests for blood are very simple and sensitive tests used in the search for evidence. They also provide initial information on the nature of stains. A second test can confirm their nature. However, these tests can present false-negative results for different reasons. Some of those reasons have been studied, while others, those caused by the substrate material that contains the stain, are less well known. This work studies the effect of one component of a leather substrate-quebracho extract-on presumptive and human hemoglobin blood tests. Assays were performed using samples of blood dilutions contaminated with quebracho extract and others formed on a substrate containing the contaminant. Results show an undoubted interference that causes false negatives and even visible to the naked eye stains and also indicate that some tests (phenolphthalein) are more affected than others. Examiners should be taken into account when working on this kind of substrates. © 2017 American Academy of Forensic Sciences.

  9. Establishing a sample-to cut-off ratio for lab-diagnosis of hepatitis C virus in Indian context.

    PubMed

    Tiwari, Aseem K; Pandey, Prashant K; Negi, Avinash; Bagga, Ruchika; Shanker, Ajay; Baveja, Usha; Vimarsh, Raina; Bhargava, Richa; Dara, Ravi C; Rawat, Ganesh

    2015-01-01

    Lab-diagnosis of hepatitis C virus (HCV) is based on detecting specific antibodies by enzyme immuno-assay (EIA) or chemiluminescence immuno-assay (CIA). Center for Disease Control reported that signal-to-cut-off (s/co) ratios in anti-HCV antibody tests like EIA/CIA can be used to predict the probable result of supplemental test; above a certain s/co value it is most likely to be true-HCV positive result and below that certain s/co it is most likely to be false-positive result. A prospective study was undertaken in patients in tertiary care setting for establishing this "certain" s/co value. The study was carried out in consecutive patients requiring HCV testing for screening/diagnosis and medical management. These samples were tested for anti-HCV on CIA (VITROS(®) Anti-HCV assay, Ortho-Clinical Diagnostics, New Jersey) for calculating s/co value. The supplemental nucleic acid test used was polymerase chain reaction (PCR) (Abbott). PCR test results were used to define true negatives, false negatives, true positives, and false positives. Performance of different putative s/co ratios versus PCR was measured using sensitivity, specificity, positive predictive value and negative predictive value and most appropriate s/co was considered on basis of highest specificity at sensitivity of at least 95%. An s/co ratio of ≥6 worked out to be over 95% sensitive and almost 92% specific in 438 consecutive patient samples tested. The s/co ratio of six can be used for lab-diagnosis of HCV infection; those with s/co higher than six can be diagnosed to have HCV infection without any need for supplemental assays.

  10. Experimental Design for a Sponge-Wipe Study to Relate the Recovery Efficiency and False Negative Rate to the Concentration of a Bacillus anthracis Surrogate for Six Surface Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piepel, Gregory F.; Amidan, Brett G.; Krauter, Paula

    2011-05-01

    Two concerns were raised by the Government Accountability Office following the 2001 building contaminations via letters containing Bacillus anthracis (BA). These included the: 1) lack of validated sampling methods, and 2) need to use statistical sampling to quantify the confidence of no contamination when all samples have negative results. Critical to addressing these concerns is quantifying the false negative rate (FNR). The FNR may depend on the 1) method of contaminant deposition, 2) surface concentration of the contaminant, 3) surface material being sampled, 4) sample collection method, 5) sample storage/transportation conditions, 6) sample processing method, and 7) sample analytical method.more » A review of the literature found 17 laboratory studies that focused on swab, wipe, or vacuum samples collected from a variety of surface materials contaminated by BA or a surrogate, and used culture methods to determine the surface contaminant concentration. These studies quantified performance of the sampling and analysis methods in terms of recovery efficiency (RE) and not FNR (which left a major gap in available information). Quantifying the FNR under a variety of conditions is a key aspect of validating sample and analysis methods, and also for calculating the confidence in characterization or clearance decisions based on a statistical sampling plan. A laboratory study was planned to partially fill the gap in FNR results. This report documents the experimental design developed by Pacific Northwest National Laboratory and Sandia National Laboratories (SNL) for a sponge-wipe method. The testing was performed by SNL and is now completed. The study investigated the effects on key response variables from six surface materials contaminated with eight surface concentrations of a BA surrogate (Bacillus atrophaeus). The key response variables include measures of the contamination on test coupons of surface materials tested, contamination recovered from coupons by sponge-wipe samples, RE, and FNR. The experimental design involves 16 test runs, performed in two blocks of eight runs. Three surface materials (stainless steel, vinyl tile, and ceramic tile) were tested in the first block, while three other surface materials (plastic, painted wood paneling, and faux leather) were tested in the second block. The eight surface concentrations of the surrogate were randomly assigned to test runs within each block. Some of the concentrations were very low and presented challenges for deposition, sampling, and analysis. However, such tests are needed to investigate RE and FNR over the full range of concentrations of interest. In each run, there were 10 test coupons of each of the three surface materials. A positive control sample was generated at the same time as each test sample. The positive control results will be used to 1) calculate RE values for the wipe sampling and analysis method, and 2) fit RE- and FNR-concentration equations, for each of the six surface materials. Data analyses will support 1) estimating the FNR for each combination of contaminant concentration and surface material, 2) estimating the surface concentrations and their uncertainties of the contaminant for each combination of concentration and surface material, 3) estimating RE (%) and their uncertainties for each combination of contaminant concentration and surface material, 4) fitting FNR-concentration and RE-concentration equations for each of the six surface materials, 5) assessing goodness-of-fit of the equations, and 6) quantifying the uncertainty in FNR and RE predictions made with the fitted equations.« less

  11. Serological and molecular investigation for brucellosis in swine in selected districts of Uganda.

    PubMed

    Erume, Joseph; Roesel, Kristina; Dione, Michel M; Ejobi, Francis; Mboowa, Gerald; Kungu, Joseph M; Akol, Joyce; Pezo, Danilo; El-Adawy, Hosny; Melzer, Falk; Elschner, Mandy; Neubauer, Heinrich; Grace, Delia

    2016-08-01

    Brucellosis is a notifiable zoonotic disease affecting livestock, humans, and wildlife in Uganda. Pigs can be infected with human pathogenic Brucella suis biovars 1 and 3 and can be a significant source of brucellosis for humans. Uganda has a rapidly growing pig population, and the pork consumption per capita is the highest in East Africa. The objective of this work was to determine the seroprevalence of brucellosis in Ugandan pigs. A cross-sectional serosurvey of pigs was conducted in three of the major pig-keeping districts in Uganda (Masaka (n = 381 samples), Mukono (n = 398), and Kamuli (n = 414)). In addition, pigs originating from these districts were sampled in the major pig abattoir in Kampala (n = 472). In total, 1665 serum samples were investigated by serological and molecular tests. Only three putative brucellosis-positive samples were detected serologically using indirect ELISA. These sera were found negative for Brucella antibodies by CFT; however, two had antibodies against Yersinia enterocolitica as determined by SAT. Presence of antibodies against Yersiniae was confirmed by Y. enterocolitica antibody-specific ELISA. The two Yersiniae ELISA-positive samples were brucellosis negative using real-time PCR. We tested additional 142 sera from the 1665 samples with real-time PCR. All tested negative. Under this type of production system, we expect a maximum B. suis prevalence of less than 1 % at 95 % confidence level, and therefore, the risk of acquiring brucellosis from the pigs or their products is negligible. However, pigs may harbor the zoonotic Y. enterocolitica. This is the first study to investigate the occurrence of brucellosis in pigs in Uganda and the first study to report Y. enterocolitica antibodies in swine in Uganda.

  12. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.

    PubMed

    Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz

    The aim of this study was to evaluate the QuickVue ® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue ® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue ® RSV Test and viral load or specific strain. The QuickVue ® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue ® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  13. External quality assessment program for detection of glucose-6-phosphate dehydrogenase deficiency in the Guangxi region.

    PubMed

    Tang, Juan; Zhou, Xiangyang; Liu, Xiaochun; Ning, Leping; Zhou, Weiya; He, Yi

    2017-09-01

    The aim of this study is to improve the quality of testing for glucose-6-phosphate dehydrogenase (G6PD) deficiency through evaluation and analysis of the laboratory tests for G6PD activity. External quality assessment (EQA) was carried out twice per year with five samples each from 2014 to 2016. Samples were used for quantitative and qualitative assays. Quantitative results were collected, qualitative results were determined with reference values, and information about methods, reagents and instruments from participating laboratories within the required time. Laboratory performance scores, coefficient of variation (CV), and the rates of false negative and positive results were calculated. As a result, a total of 2,834 cases of negative quality control (QC) samples and 2,451 cases of positive QC samples were assessed, where the rates of false negative and false positive results were 1.31% (37/2,834) and 1.34% (33/2,451), respectively. Quantitative results indicated an increasing trend in testing quality, which were consistent with conclusions based on the comparison of EQA full-score and acceptable ratio in six assessments. The 2nd assay in 2016 had the best full-score ratio of 68.9% (135/196) and best acceptable ratio of 84.2% (165/196). There was a decreasing trend in the average CV of six reagents produced in China, and the range of average CV increased to 14.6-23.6% in 2016. The average CV of low level and high level samples was 22.5% and 15.3%, respectively, demonstrating that samples with low G6PD activity have greater interlaboratory CV values. In conclusion, laboratories improved their testing quality and provided better diagnostic service for G6PD deficiency in areas with high incidence after participation in the EQA program in the Guangxi region.

  14. Evaluation of timing of re-appearance of VBNC Legionella for risk assessment in hospital water distribution systems.

    PubMed

    Marinelli, L; Cottarelli, A; Solimini, A G; Del Cimmuto, A; De Giusti, M

    2017-01-01

    In this study we estimated the presence of Legionella species, viable but non-culturable (VBNC), in hospital water networks. We also evaluated the time and load of Legionella appearance in samples found negative using the standard culture method. A total of 42 samples was obtained from the tap water of five hospital buildings. The samples were tested for Legionella by the standard culture method and were monitored for up to 12 months for the appearance of VBNC Legionella. All the 42 samples were negative at the time of collection. Seven of the 42 samples (17.0%) became positive for Legionella at different times of monitoring. The time to the appearance of VBNC Legionella was extremely variable, from 15 days to 9 months from sampling. The most frequent Legionella species observed were Legionella spp and L. anisa and only in one sample L. pneumophila srg.1. Our study confirms the presence of VBNC Legionella in samples resulting negative using the standard culture method and highlights the different time to its appearance that can occur several months after sampling. The results are important for risk assessment and risk management of engineered water systems.

  15. HLA-B*5701 clinical testing: early experience in the United States.

    PubMed

    Faruki, Hawazin; Heine, Uwe; Brown, Trisha; Koester, Ruth; Lai-Goldman, Myla

    2007-10-01

    HLA-B*5701 testing to provide risk stratification for abacavir hypersensitivity has the potential to reduce incidence of hypersensitivity reactions in susceptible individuals. Early experience with clinical HLA-B*5701 testing of the first 100 specimens, from a large clinical reference laboratory in the United States, is presented. Patient samples were tested using a two-step approach. The first step allowed rapid identification of most HLA-B*5701-negative samples in a high throughput mode. The second step involved resolution of putative positives by DNA sequencing to identify B*5701 specifically as well as other B57 subtypes. Test reporting included a phone call from a genetic counselor to obtain the ethnic background and indication for testing and to provide a patient-specific interpretation. The patients population was comprised of Caucasians, 84%; Hispanics, 13%; and African Americans, 3%. Among the 100 samples tested, 92% were HLA-B*5701-negative and 8% were positive for the HLA-B*5701 allele. All HLA-B*5701 allele positives were identified in Caucasian patients. Where the indication for testing was obtainable (57 patients), pre-abacavir therapy screening was the indication 67% of the time. Clarification of previous suspected history of hypersensitivity was the indication 33% of the time. Among samples tested to help clarify a previous history of hypersensitivity, 16/19 or 84% did not carry the HLA-B*5701 allele whereas 3/19 (16%) were carriers of the HLA-B*5701 allele. Early utilization of HLA-B*5701 testing in community practice was not always consistent with the clinical indications for testing. Post-test communication assisted in providing physician education and interpretation of patient-specific results.

  16. Detection of maternal DNA in placental/umbilical cord blood by locus-specific amplification of the noninherited maternal HLA gene.

    PubMed

    Scaradavou, A; Carrier, C; Mollen, N; Stevens, C; Rubinstein, P

    1996-08-15

    A critical issue regarding the broader utilization of placental/ umbilical cord blood (PCB) in unrelated bone marrow restoration is the possibility of contamination with maternal lymphocytes capable of immunological reactivity against the eventual recipient. On transplantation, such maternal cells might lead to graft-versus-host disease (GVHD) even if the intended donor's neonatal lymphocytes were unresponsive. We measured the proportion of PCB samples that were contaminated with maternal cells. Placental-maternal sample pairs were selected so that the mother was heterozygous for the DR53 haplotype, whereas the placental sample was DR53-negative. The PCB samples were investigated for the presence of the noninherited maternal gene DRB4, exclusive to the DR53 haplotypes. Locus-specific polymerase chain reaction amplification with DRB4 sequence-specific primers was followed by either gel electrophoresis or blotting and hybridization to an internal sequence DRB4 probe. Polymerase chain reaction products from DNA mixtures containing as low as 0.5 ng of a DRB4-positive DNA control in 1.0 microgram of a DRB4-negative DNA sample (1:2 x 10(3) dilution) showed a visible DRB4 band in agarose gels stained with ethidium bromide. Locus-specific hybridization increased the detection sensitivity to 1:10(5) (0.01 ng of the DRB4-positive DNA control). Control mixtures of known amounts of DRB4-positive and -negative DNA were included in all experiments. Comparison of the thickness of DRB4 bands after electrophoresis and the intensity of the DRB4-specific hybridization signals to the concentration controls allowed a rough estimation of the amount of maternal DNA in the placental blood specimens. A total of 213 PCB samples were tested. By gel electrophoresis, DRB4-specific bands were observed to be as strong or stronger in 23 (10.8%) samples as those in the 1:2 x 10(3) control, and 153 (17.8%) samples were negative in this test. The remaining 37 (17.3%) samples disclosed weaker DRB4 bands, suggesting the presence of maternal genetic material. By hybridization, 81 (38%) samples were positive and 132 were negative for the noninherited maternal gene. Review of the clinical characteristics of the mothers (demographics and labor and delivery information), the newborns (birth weight, sex, and gestational age), and PCB collections (placental weight, white blood cell count, and collected volume) failed to show any significant differences between the units testing positive or negative for the noninherited maternal gene. Thus, transplantable PCB units carry a high probability of having maternal DNA in detectable amounts. Whether this DNA comes from potentially graft-versus-host disease-inducing maternal lymphocytes or whether the putatively transplacentally-acquired maternal cells are immunologically dysfunctional, as in most infants with severe combined immunodeficiency disease, remains to be shown.

  17. Mutagenicity in emissions from coal- and oil-fired boilers.

    PubMed Central

    Alfheim, I; Bergström, J G; Jenssen, D; Møller, M

    1983-01-01

    The mutagenicity of emission samples from three oil-fired and four coal-fired boilers have been compared by using the Salmonella/microsome assay. Very little or no mutagenic activity was observed in samples from five of these boilers. The sample from one oil-fired boiler showed mutagenic activity of about 500 revertants/MJ, and the sample from a coal-fired fluidized bed combustor had an activity of 58,000 revertants/MJ measured with strain TA 98 in the absence of metabolic activation. All samples contained substances that were cytotoxic to the test bacteria, thus making it difficult to obtain linear dose-response curves. Mutagenic activity at low levels may remain undetected due to this toxicity of the samples. Samples with mutagenic activity below the detection limit in the Salmonella test have also been tested for forward mutations at the HGPRT locus in V79 hamster cells. Weak mutagenic effects were detected in two of the samples, whereas the sample from one oil-fired boiler remained negative. In this test, as well as in the Salmonella test, a strong cytotoxic effect could be observed with all samples. PMID:6825617

  18. Undiagnosed Acute Viral Febrile Illnesses, Sierra Leone

    PubMed Central

    Rossi, Cynthia A.; Khan, Sheik H.; Goba, Augustine; Fair, Joseph N.

    2014-01-01

    Sierra Leone in West Africa is in a Lassa fever–hyperendemic region that also includes Guinea and Liberia. Each year, suspected Lassa fever cases result in submission of ≈500–700 samples to the Kenema Government Hospital Lassa Diagnostic Laboratory in eastern Sierra Leone. Generally only 30%–40% of samples tested are positive for Lassa virus (LASV) antigen and/or LASV-specific IgM; thus, 60%–70% of these patients have acute diseases of unknown origin. To investigate what other arthropod-borne and hemorrhagic fever viral diseases might cause serious illness in this region and mimic Lassa fever, we tested patient serum samples that were negative for malaria parasites and LASV. Using IgM-capture ELISAs, we evaluated samples for antibodies to arthropod-borne and other hemorrhagic fever viruses. Approximately 25% of LASV-negative patients had IgM to dengue, West Nile, yellow fever, Rift Valley fever, chikungunya, Ebola, and Marburg viruses but not to Crimean-Congo hemorrhagic fever virus. PMID:24959946

  19. European Multicenter Study on Analytical Performance of DxN Veris System HCV Assay.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Gismondo, Maria Rita; Hofmann, Jörg; Izopet, Jacques; Kühn, Sebastian; Lombardi, Alessandra; Marcos, Maria Angeles; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel W

    2017-04-01

    The analytical performance of the Veris HCV Assay for use on the new and fully automated Beckman Coulter DxN Veris Molecular Diagnostics System (DxN Veris System) was evaluated at 10 European virology laboratories. Precision, analytical sensitivity, specificity, and performance with negative samples, linearity, and performance with hepatitis C virus (HCV) genotypes were evaluated. Precision for all sites showed a standard deviation (SD) of 0.22 log 10 IU/ml or lower for each level tested. Analytical sensitivity determined by probit analysis was between 6.2 and 9.0 IU/ml. Specificity on 94 unique patient samples was 100%, and performance with 1,089 negative samples demonstrated 100% not-detected results. Linearity using patient samples was shown from 1.34 to 6.94 log 10 IU/ml. The assay demonstrated linearity upon dilution with all HCV genotypes. The Veris HCV Assay demonstrated an analytical performance comparable to that of currently marketed HCV assays when tested across multiple European sites. Copyright © 2017 American Society for Microbiology.

  20. Fast preparation of a long chimeric armored RNA as controls for external quality assessment for molecular detection of Zika virus.

    PubMed

    Lin, Guigao; Zhang, Kuo; Zhang, Dong; Han, Yanxi; Xie, Jiehong; Li, Jinming

    2017-03-01

    The emergence of Zika virus demands accurate laboratory diagnostics. Nucleic acid testing is currently the definitive method for diagnosis of Zika infection. In 2016, an external quality assurance (EQA) for assessing the quality of molecular testing of Zika virus was carried out in China. A single armored RNA encapsulating a 4942-nucleotides (nt) long specific RNA sequence of Zika virus was prepared and used as positive samples. A pre-tested EQA panel, consisting of 4 negative and 6 positive samples with different concentrations of armored RNA, was distributed to 38 laboratories that perform molecular detection of Zika virus. A total of 39 data sets (1 laboratory used two test kits in parallel), produced by using commercial (n=38) or laboratory developed (n=1) quantitative reverse-transcriptase PCR (qRT-PCR) kits, were received. Of these, 35 (89.7%) had correct results for all 10 samples, and 4 (10.3%) reported at least 1 error (11 in total). The testing errors were all false-negatives, highlighting the need of improvements in detecting sensitivity. The EQA reveals that the majority of participating laboratories are proficient in molecular testing of Zika virus. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Molecular testing of adult Pacific salmon and trout (Oncorhynchus spp.) for several RNA viruses demonstrates widespread distribution of piscine orthoreovirus in Alaska and Washington

    USGS Publications Warehouse

    Purcell, Maureen; Thompson, Rachel L.; Evered, Joy; Kerwin, John; Meyers, Ted R.; Stewart, Bruce; Winton, James

    2018-01-01

    This research was initiated in conjunction with a systematic, multiagency surveillance effort in the United States (U.S.) in response to reported findings of infectious salmon anaemia virus (ISAV) RNA in British Columbia, Canada. In the systematic surveillance study reported in a companion paper, tissues from various salmonids taken from Washington and Alaska were surveyed for ISAV RNA using the U.S.-approved diagnostic method, and samples were released for use in this present study only after testing negative. Here, we tested a subset of these samples for ISAV RNA with three additional published molecular assays, as well as for RNA from salmonid alphavirus (SAV), piscine myocarditis virus (PMCV) and piscine orthoreovirus (PRV). All samples (n = 2,252; 121 stock cohorts) tested negative for RNA from ISAV, PMCV, and SAV. In contrast, there were 25 stock cohorts from Washington and Alaska that had one or more individuals test positive for PRV RNA; prevalence within stocks varied and ranged from 2% to 73%. The overall prevalence of PRV RNA-positive individuals across the study was 3.4% (77 of 2,252 fish tested). Findings of PRV RNA were most common in coho (Oncorhynchus kisutch Walbaum) and Chinook (O. tshawytscha Walbaum) salmon.

  2. Mutagenicity of edible palm oil on the Ghanaian market before and after repeated heating.

    PubMed

    Asare, George A; Okyere, Genevieve O; Asante, Matilda; Brown, Charles A; Santa, Sheila; Asiedu, Bernice

    2013-12-01

    Red palm oil produced in Ghana largely by village folks has never been tested for its mutagenic potential. The study aimed at determining the mutagenicity of high-energy heated red palm oil (RRPO) and refined, bleached imported palm oil (PO) on the Ghanaian market. Samples of RRPO and PO were 1× and 5× heated for 10 min at 180 °C with a cooling period of 5 h in-between. Unheated, together with heated samples, were tested for mutagenicity using Salmonella typhimurium TA 98 and TA 100 tester stains. Unheated PO was negative for the Ames mutagenicity test with TA 98 strain. However, 1× and 5× heated PO were mutagenic (P = 0.05, each). Testing PO, using TA 100 strain was negative. RRPO was mutagenic with TA 98 strain for heated oils (P = 0.05, each). Assays with TA 100 strain showed highly significant mutations (P = 0.001, each) that increased with increasing heating frequency. PO 1× and 5× heated samples caused significant frameshift mutation in the S. typhimurium TA 98 strain. RRPO caused highly significant point and frameshift mutations in heated samples. Furthermore, unheated RRPO mutagenic potential has serious health implications. © 2013 Institute of Food Technologists®

  3. Effect of paratuberculosis on culling, milk production, and milk quality in dairy herds.

    PubMed

    Hendrick, Steven H; Kelton, David F; Leslie, Ken E; Lissemore, Kerry D; Archambault, Marie; Duffield, Todd F

    2005-10-15

    To determine the effect of paratuberculosis on culling, milk production, and milk quality in infected dairy herds. Cross-sectional study. 689 lactating dairy cows in 9 herds. Milk, blood, and fecal samples were obtained from all cows. Fecal samples were evaluated via mycobacterial culture. Serum samples were tested with a commercially available ELISA for antibodies against Mycobacterium avium subsp paratuberculosis, and preserved milk samples were tested with an ELISA for antibodies against M paratuberculosis. Mixed effect and proportional hazards models were used to determine the effect of paratuberculosis on 305-day milk, fat, and protein production; somatic cell count linear score; and the risk of culling. Cows with positive results of bacteriologic culture of feces and milk ELISA produced less milk, fat, and protein, compared with herdmates with negative results. No difference in 305-day milk or fat production was detected in cows with positive results of serum ELISA, compared with seronegative cows. The 3 survival analyses revealed that cows with positive results of each test were at higher risk of being culled than cows with negative results. Paratuberculosis status, as determined by use of all 3 diagnostic tests, was not associated with milk somatic cell count linear score. Results suggest that for the 9 herds in this study, paratuberculosis significantly decreased milk production and cow longevity.

  4. Isolation of sulfur reducing and oxidizing bacteria found in contaminated drywall.

    PubMed

    Hooper, Dennis G; Shane, John; Straus, David C; Kilburn, Kaye H; Bolton, Vincent; Sutton, John S; Guilford, Frederick T

    2010-02-05

    Drywall from China has been reported to release sulfur producing products which are corrosive to metals, result in noxious odors, and represent a significant health risk. It has been reported that these emissions produce medical symptoms such as respiratory or asthma type problems, sinusitis, gastrointestinal disorders, and vision problems in home owners and their household pets. We report here a method of identifying a causative agent for these emissions by sampling affected gypsum wallboard and subjecting those samples to Real Time Polymerase Chain Reaction [RT-PCR] studies. Specific DNA probes and primers have been designed and patented that detect a specific iron and sulfur reducing bacterium (i.e., Thiobacillus ferrooxidans). One hundred percent of affected drywall samples obtained from homes located in the southeastern United States tested positive for the presence of T. ferrooxidans. All negative controls consisting of unaffected wallboard and internal controls, Geotrichum sp., tested negative within our limits of detection.

  5. Isolation of Sulfur Reducing and Oxidizing Bacteria Found in Contaminated Drywall

    PubMed Central

    Hooper, Dennis G.; Shane, John; Straus, David C.; Kilburn, Kaye H.; Bolton, Vincent; Sutton, John S.; Guilford, Frederick T.

    2010-01-01

    Drywall from China has been reported to release sulfur producing products which are corrosive to metals, result in noxious odors, and represent a significant health risk. It has been reported that these emissions produce medical symptoms such as respiratory or asthma type problems, sinusitis, gastrointestinal disorders, and vision problems in home owners and their household pets. We report here a method of identifying a causative agent for these emissions by sampling affected gypsum wallboard and subjecting those samples to Real Time Polymerase Chain Reaction [RT-PCR] studies. Specific DNA probes and primers have been designed and patented that detect a specific iron and sulfur reducing bacterium (i.e., Thiobacillus ferrooxidans). One hundred percent of affected drywall samples obtained from homes located in the southeastern United States tested positive for the presence of T. ferrooxidans. All negative controls consisting of unaffected wallboard and internal controls, Geotrichum sp., tested negative within our limits of detection. PMID:20386658

  6. Actor and Partner Effects of Attachment on Relationship Satisfaction and Sexual Satisfaction Across the Genders: An APIM Approach.

    PubMed

    Conradi, Henk Jan; Noordhof, Arjen; Dingemanse, Pieter; Barelds, Dick P H; Kamphuis, Jan H

    2017-10-01

    Previous studies found gender differences in relationship satisfaction and sexuality. We tested gender differences in associations between attachment, a lasting relationship determinant, and two outcomes, relationship and sexual satisfaction. This study improves on earlier research by examining these associations in one Actor-Partner-Interdependence-Model, making direct statistical testing between outcomes possible. Furthermore, a community and a distressed sample (N = 113 heterosexual couples each) were included to attempt replication across samples and to examine clinical implications. In both genders, actor attachment avoidance negatively affected relationship satisfaction and (with one exception) sexual satisfaction. Also in both genders, partner attachment avoidance negatively affected sexual satisfaction. However, whereas partner attachment avoidance influenced female relationship satisfaction, it did not affect male relationship satisfaction. The findings replicated across samples. Clinical implications are discussed. © 2017 American Association for Marriage and Family Therapy.

  7. Molecular screening for hemotropic mycoplasmas in captive Barbary sheep (Ammotragus lervia) in southern Brazil

    PubMed Central

    Santos, Leonilda C.; Vidotto, Odilon; Morikawa, Vivien M.; Santos, Nelson J. R.; Vieira, Thállitha S. W. J.; Barros Filho, Ivan R.; Vieira, Rafael F. C.; Biondo, Alexander W.

    2017-01-01

    Aim: This study is part of an active surveillance program for monitoring animal health status in endangered species, and was conducted to screen captive Barbary sheep (Ammotragus lervia) for hemoplasma infection. Materials and Methods: A total of 12 blood samples were collected, DNA extracted and further tested by a pan-hemoplasma polymerase chain reaction protocol. Results: Animals were clinically healthy and not infested by ectoparasites. Although housekeeping gene DNA was successfully amplified, all the Barbary sheep samples tested negative for Mycoplasma sp. Conclusion: Notwithstanding the negative results, molecular pathogen surveys on Barbary sheep and other exotic wild mammals may provide insights regarding infection of endangered species caused by captivity stress in association with exposure to new pathogens worldwide. PMID:28919684

  8. Self-verification and social anxiety: preference for negative social feedback and low social self-esteem.

    PubMed

    Valentiner, David P; Skowronski, John J; McGrath, Patrick B; Smith, Sarah A; Renner, Kerry A

    2011-10-01

    A self-verification model of social anxiety views negative social self-esteem as a core feature of social anxiety. This core feature is proposed to be maintained through self-verification processes, such as by leading individuals with negative social self-esteem to prefer negative social feedback. This model is tested in two studies. In Study 1, questionnaires were administered to a college sample (N = 317). In Study 2, questionnaires were administered to anxiety disordered patients (N = 62) before and after treatment. Study 1 developed measures of preference for negative social feedback and social self-esteem, and provided evidence of their incremental validity in a college sample. Study 2 found that these two variables are not strongly related to fears of evaluation, are relatively unaffected by a treatment that targets such fears, and predict residual social anxiety following treatment. Overall, these studies provide preliminary evidence for a self-verification model of social anxiety.

  9. The role of negative urgency and expectancies in problem drinking and disordered eating: testing a model of comorbidity in pathological and at-risk samples.

    PubMed

    Fischer, Sarah; Settles, Regan; Collins, Brittany; Gunn, Rachel; Smith, Gregory T

    2012-03-01

    The aim of this study was to test hypotheses derived from a model that explains both the comorbidity of problem drinking and eating disorder symptoms and the difference in risk process between the two disorders. In Study One, the authors examined four personality constructs typically associated with rash action (sensation seeking, lack of planning, lack of persistence, and negative urgency) and disorder-specific expectancies in samples of women with eating disorders, substance dependence disorders, comorbid conditions, and no symptoms (N = 104). Negative urgency, the tendency to act rashly when distressed, differentiated the disordered groups from the control group. In contrast, learned expectancies differentiated among clinical groups. Women with eating disorders endorsed high levels of eating and dieting expectancies and women with substance use disorders endorsed high levels of alcohol expectancies, while comorbid women endorsed high levels of both. In Study Two, this pattern of findings was replicated in a sample of fifth grade girls (N = 905). Girls who had engaged in binge eating, alcohol use, or both had higher levels of negative urgency than asymptomatic girls, and the pattern of outcome expectancy endorsement was disorder specific. Negative urgency may represent a general, personality influence on both eating disordered behaviors and symptoms of alcohol dependence, which, when combined with learned, behavior-specific expectancies, leads to specific addictive behavior patterns. PsycINFO Database Record (c) 2012 APA, all rights reserved.

  10. Chlamydia and gonorrhoea contamination of clinic surfaces.

    PubMed

    Lewis, Natasha; Dube, Gail; Carter, Christine; Pitt, Rachel; Alexander, Sarah; Ison, Catherine A; Harding, Jan; Brown, Louise; Fryer, John; Hodson, James; Ross, Jonathan

    2012-10-01

    Nucleic acid amplification tests, with their ability to detect very small amounts of nucleic acid, have become the principle diagnostic tests for Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (GC) in many sexual health clinics. The aim of this study was to investigate the extent of surface contamination with CT and GC within a city centre sexual health clinic and to evaluate the potential for contamination of containers used for the collection of self-taken swabs. Surface contamination with CT and GC was assessed by systematically sampling 154 different sites within one clinic using transcription-mediated amplification (TMA), quantitative PCR and culture. The caps of containers used by patients to collect self-taken samples were also tested for CT and GC using TMA. Of the 154 sites sampled, 20 (13.0%) tested positive on TMA. Of these, five (3.2%) were positive for CT alone, 11 (7.1%) for GC alone and four (2.6%) for both CT and GC. The proportion of GC TMA-positive test results differed by gender, with 11 (18.3%) positive results from the male patient clinic area compared with one (1.6%) from the female area (p=0.002). Positive samples were obtained from a variety of locations in the clinic, but the patient toilets were more likely to be contaminated than examination rooms (p=0.015). Quantitative PCR and culture assays were negative for all samples. 46 caps of the containers used for self-taken swabs were negative for both CT and GC on TMA testing. Surface contamination with chlamydial and gonococcal rRNA can occur within sexual health clinics, but the quantity of nucleic acid detected is low and infection risk to patients and staff is small. There remains a potential risk of contamination of patient samples leading to false-positive results.

  11. Investigation into low-level anti-rubella virus IgG results reported by commercial immunoassays.

    PubMed

    Dimech, Wayne; Arachchi, Nilukshi; Cai, Jingjing; Sahin, Terri; Wilson, Kim

    2013-02-01

    Since the 1980s, commercial anti-rubella virus IgG assays have been calibrated against a WHO International Standard and results have been reported in international units per milliliter (IU/ml). Laboratories testing routine patients' samples collected 100 samples that gave anti-rubella virus IgG results of 40 IU/ml or less from each of five different commercial immunoassays (CIA). The total of 500 quantitative results obtained from 100 samples from each CIA were compared with results obtained from an in-house enzyme immunoassay (IH-EIA) calibrated using the WHO standard. All 500 samples were screened using a hemagglutination inhibition assay (HAI). Any sample having an HAI titer of 1:8 or less was assigned a negative anti-rubella virus antibody status. If the HAI titer was greater than 1:8, the sample was tested in an immunoblot (IB) assay. If the IB result was negative, the sample was assigned a negative anti-rubella virus IgG status; otherwise, the sample was assigned a positive status. Concordance between the CIA qualitative results and the assigned negative status ranged from 50.0 to 93.8% and 74.5 to 97.8% for the assigned positive status. Using a receiver operating characteristic analysis with the cutoff set at 10 IU/ml, the estimated sensitivity and specificity ranged from 70.2 to 91.2% and 65.9 to 100%, respectively. There was poor correlation between the quantitative CIA results and those obtained by the IH-EIA, with the coefficient of determination (R(2)) ranging from 0.002 to 0.413. Although CIAs have been calibrated with the same international standard for more than 2 decades, the level of standardization continues to be poor. It may be time for the scientific community to reevaluate the relevance of quantification of anti-rubella virus IgG.

  12. Investigation into Low-Level Anti-Rubella Virus IgG Results Reported by Commercial Immunoassays

    PubMed Central

    Arachchi, Nilukshi; Cai, Jingjing; Sahin, Terri; Wilson, Kim

    2013-01-01

    Since the 1980s, commercial anti-rubella virus IgG assays have been calibrated against a WHO International Standard and results have been reported in international units per milliliter (IU/ml). Laboratories testing routine patients' samples collected 100 samples that gave anti-rubella virus IgG results of 40 IU/ml or less from each of five different commercial immunoassays (CIA). The total of 500 quantitative results obtained from 100 samples from each CIA were compared with results obtained from an in-house enzyme immunoassay (IH-EIA) calibrated using the WHO standard. All 500 samples were screened using a hemagglutination inhibition assay (HAI). Any sample having an HAI titer of 1:8 or less was assigned a negative anti-rubella virus antibody status. If the HAI titer was greater than 1:8, the sample was tested in an immunoblot (IB) assay. If the IB result was negative, the sample was assigned a negative anti-rubella virus IgG status; otherwise, the sample was assigned a positive status. Concordance between the CIA qualitative results and the assigned negative status ranged from 50.0 to 93.8% and 74.5 to 97.8% for the assigned positive status. Using a receiver operating characteristic analysis with the cutoff set at 10 IU/ml, the estimated sensitivity and specificity ranged from 70.2 to 91.2% and 65.9 to 100%, respectively. There was poor correlation between the quantitative CIA results and those obtained by the IH-EIA, with the coefficient of determination (R2) ranging from 0.002 to 0.413. Although CIAs have been calibrated with the same international standard for more than 2 decades, the level of standardization continues to be poor. It may be time for the scientific community to reevaluate the relevance of quantification of anti-rubella virus IgG. PMID:23254301

  13. Standardization of a TaqMan-based real-time PCR for the detection of Mycobacterium tuberculosis-complex in human sputum.

    PubMed

    Barletta, Francesca; Vandelannoote, Koen; Collantes, Jimena; Evans, Carlton A; Arévalo, Jorge; Rigouts, Leen

    2014-10-01

    Real-time polymerase chain reaction (qPCR) was optimized for detecting Mycobacterium tuberculosis in sputum. Sputum was collected from patients (N = 112) with suspected pulmonary tuberculosis, tested by smear microscopy, decontaminated, and split into equal aliquots that were cultured in Löwenstein-Jensen medium and tested by qPCR for the small mobile genetic element IS6110. The human ERV3 sequence was used as an internal control. 3 of 112 (3%) qPCR failed. For the remaining 109 samples, qPCR diagnosed tuberculosis in 79 of 84 patients with culture-proven tuberculosis, and sensitivity was greater than microscopy (94% versus 76%, respectively, P < 0.05). The qPCR sensitivity was similar (P = 0.9) for smear-positive (94%, 60 of 64) and smear-negative (95%, 19 of 20) samples. The qPCR was negative for 24 of 25 of the sputa with negative microscopy and culture (diagnostic specificity 96%). The qPCR had 99.5% sensitivity and specificity for 211 quality control samples including 84 non-tuberculosis mycobacteria. The qPCR cost ∼5US$ per sample and provided same-day results compared with 2-6 weeks for culture. © The American Society of Tropical Medicine and Hygiene.

  14. Experimental Design for a Sponge-Wipe Study to Relate the Recovery Efficiency and False Negative Rate to the Concentration of a Bacillus anthracis Surrogate for Six Surface Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piepel, Gregory F.; Amidan, Brett G.; Krauter, Paula

    2010-12-16

    Two concerns were raised by the Government Accountability Office following the 2001 building contaminations via letters containing Bacillus anthracis (BA). These included the: 1) lack of validated sampling methods, and 2) need to use statistical sampling to quantify the confidence of no contamination when all samples have negative results. Critical to addressing these concerns is quantifying the probability of correct detection (PCD) (or equivalently the false negative rate FNR = 1 - PCD). The PCD/FNR may depend on the 1) method of contaminant deposition, 2) surface concentration of the contaminant, 3) surface material being sampled, 4) sample collection method, 5)more » sample storage/transportation conditions, 6) sample processing method, and 7) sample analytical method. A review of the literature found 17 laboratory studies that focused on swab, wipe, or vacuum samples collected from a variety of surface materials contaminated by BA or a surrogate, and used culture methods to determine the surface contaminant concentration. These studies quantified performance of the sampling and analysis methods in terms of recovery efficiency (RE) and not PCD/FNR (which left a major gap in available information). Quantifying the PCD/FNR under a variety of conditions is a key aspect of validating sample and analysis methods, and also for calculating the confidence in characterization or clearance decisions based on a statistical sampling plan. A laboratory study was planned to partially fill the gap in PCD/FNR results. This report documents the experimental design developed by Pacific Northwest National Laboratory and Sandia National Laboratories (SNL) for a sponge-wipe method. The study will investigate the effects on key response variables from six surface materials contaminated with eight surface concentrations of a BA surrogate (Bacillus atrophaeus). The key response variables include measures of the contamination on test coupons of surface materials tested, contamination recovered from coupons by sponge-wipe samples, RE, and PCD/FNR. The experimental design involves 16 test runs, to be performed in two blocks of eight runs. Three surface materials (stainless steel, vinyl tile, and ceramic tile) were tested in the first block, while three other surface materials (plastic, painted wood paneling, and faux leather) will be tested in the second block. The eight surface concentrations of the surrogate were randomly assigned to test runs within each block. Some of the concentrations will be very low and may present challenges for deposition, sampling, and analysis. However, such tests are needed to investigate RE and PCD/FNR over the full range of concentrations of interest. In each run, there will be 10 test coupons of each of the three surface materials. A positive control sample will be generated prior to each test sample. The positive control results will be used to 1) calculate RE values for the wipe sampling and analysis method, and 2) fit RE- and PCD-concentration equations, for each of the six surface materials. Data analyses will support 1) estimating the PCD for each combination of contaminant concentration and surface material, 2) estimating the surface concentrations and their uncertainties of the contaminant for each combination of concentration and surface material, 3) estimating RE (%) and their uncertainties for each combination of contaminant concentration and surface material, 4) fitting PCD-concentration and RE-concentration equations for each of the six surface materials, 5) assessing goodness-of-fit of the equations, and 6) quantifying the uncertainty in PCD and RE predictions made with the fitted equations.« less

  15. Evaluating laboratory approaches to the identification of lupus anticoagulants: a diagnostic challenge from the RCPA Haematology QAP.

    PubMed

    Bonar, Roslyn; Favaloro, Emmanuel; Zebeljan, Diane; Rosenfeld, David; Kershaw, Geoff; Mohammed, Soma; Marsden, Katherine; Hertzberg, Mark

    2012-04-01

    Laboratory identification of lupus anticoagulants (LA), an important component of the clinical diagnosis of the autoimmune disorder antiphospholipid syndrome (APS), is challenged by the heterogeneity of tests available, the diagnostic and laboratory approach undertaken, and the heterogeneity of the autoantibodies present. : To assess the laboratory approach for investigation of LA, as well as the utility of various tests and test approaches, given a difficult clinical scenario in which LA might or might not be present. Ninety-three participants in the Royal College of Pathologists of Australasia (RCPA) Haematology Quality Assurance Program (QAP) were sent 4  mL of a complex but strongly positive LA sample blinded to the nature of the abnormality. Seventy-three (79%) participants returned results and in most cases diagnostic interpretations. The laboratory approach to LA investigation of this sample was quite varied: 34.7% of participants concluded the sample was LA negative, with 91.7% of these performing dilute Russell viper venom time (dRVVT) testing without mixing, whereas 43.5% of participants identified a strong LA, with 96.7% of these having performed mixing studies. Most laboratories reporting negative LA instead identified the false presence of specific factor inhibitors against a variety of factors, including II, V and VIII. For this difficult challenge, performance of non-mixing dRVVT was associated with a high false negative LA rate. (C) 2012 Royal College of Pathologists of Australasia.

  16. Clinical Assessment of a Nocardia PCR-Based Assay for Diagnosis of Nocardiosis.

    PubMed

    Rouzaud, Claire; Rodriguez-Nava, Véronica; Catherinot, Emilie; Méchaï, Frédéric; Bergeron, Emmanuelle; Farfour, Eric; Scemla, Anne; Poirée, Sylvain; Delavaud, Christophe; Mathieu, Daniel; Durupt, Stéphane; Larosa, Fabrice; Lengelé, Jean-Philippe; Christophe, Jean-Louis; Suarez, Felipe; Lortholary, Olivier; Lebeaux, David

    2018-06-01

    The diagnosis of nocardiosis, a severe opportunistic infection, is challenging. We assessed the specificity and sensitivity of a 16S rRNA Nocardia PCR-based assay performed on clinical samples. In this multicenter study (January 2014 to April 2015), patients who were admitted to three hospitals and had an underlying condition favoring nocardiosis, clinical and radiological signs consistent with nocardiosis, and a Nocardia PCR assay result for a clinical sample were included. Patients were classified as negative control (NC) (negative Nocardia culture results and proven alternative diagnosis or improvement at 6 months without anti- Nocardia treatment), positive control (PC) (positive Nocardia culture results), or probable nocardiosis (positive Nocardia PCR results, negative Nocardia culture results, and no alternative diagnosis). Sixty-eight patients were included; 47 were classified as NC, 8 as PC, and 13 as probable nocardiosis. PCR results were negative for 35/47 NC patients (74%). For the 12 NC patients with positive PCR results, the PCR assay had been performed with respiratory samples. These NC patients had chronic bronchopulmonary disease more frequently than did the NC patients with negative PCR results (8/12 patients [67%] versus 11/35 patients [31%]; P = 0.044). PCR results were positive for 7/8 PC patients (88%). There were 13 cases of probable nocardiosis, diagnosed solely using the PCR results; 9 of those patients (69%) had lung involvement (consolidation or nodule). Nocardia PCR testing had a specificity of 74% and a sensitivity of 88% for the diagnosis of nocardiosis. Nocardia PCR testing may be helpful for the diagnosis of nocardiosis in immunocompromised patients but interpretation of PCR results from respiratory samples is difficult, because the PCR assay may also detect colonization. Copyright © 2018 American Society for Microbiology.

  17. Raman spectroscopy based screening of IgG positive and negative sera for dengue virus infection

    NASA Astrophysics Data System (ADS)

    Bilal, M.; Saleem, M.; Bial, Maria; Khan, Saranjam; Ullah, Rahat; Ali, Hina; Ahmed, M.; Ikram, Masroor

    2017-11-01

    A quantitative analysis for the screening of immunoglobulin-G (IgG) positive human sera samples is presented for the dengue virus infection. The regression model was developed using 79 samples while 20 samples were used to test the performance of the model. The R-square (r 2) value of 0.91 was found through a leave-one-sample-out cross validation method, which shows the validity of this model. This model incorporates the molecular changes associated with IgG. Molecular analysis based on regression coefficients revealed that myristic acid, coenzyme-A, alanine, arabinose, arginine, vitamin C, carotene, fumarate, galactosamine, glutamate, lactic acid, stearic acid, tryptophan and vaccenic acid are positively correlated with IgG; while amide III, collagen, proteins, fatty acids, phospholipids and fucose are negatively correlated. For blindly tested samples, an excellent agreement has been found between the model predicted, and the clinical values of IgG. The parameters, which include sensitivity, specificity, accuracy and the area under the receiver operator characteristic curve, are found to be 100%, 83.3%, 95% and 0.99, respectively, which confirms the high quality of the model.

  18. Intolerance of Uncertainty: A Temporary Experimental Induction Procedure

    PubMed Central

    Mosca, Oriana; Lauriola, Marco; Carleton, R. Nicholas

    2016-01-01

    Background and Objectives Intolerance of uncertainty (IU) is a trans-diagnostic construct involved in anxiety and related disorders. Research focused on cross-sectional reporting, manipulating attitudes toward objective and impersonal events or on treatments designed to reduce IU in clinical populations. The current paper presents an experimental procedure for laboratory manipulations of IU and tests mediation hypotheses following the Intolerance of Uncertainty Model. Methods On pre-test, undergraduate volunteers (Study 1, n = 43;68% women. Study 2, n = 169;83.8% women) were asked to provide an idiosyncratic future negative life event. State-IU, Worry, Positive and Negative Affect were assessed after that a standardized procedure was used to identify event’s potential negative consequences. The same variables were assessed on post-test, after that participants were asked to read-through increasing and decreasing IU statements. Results Temporary changes on IU were consistently reproduced in both studies. Participants receiving increasing IU instructions reported greater state-IU, Worry and Negative Affect than those receiving decreasing IU instructions. However, this latter condition was not different from a control one (Study 2). Both studies revealed significant indirect effects of IU induction instructions on Worry and Negative Affect through state-IU. Limitations Both studies used undergraduate psychology students samples, younger than average population and predominantly female. Experimental manipulation and outcome measures belongs to the same semantic domain, uncertainty, potentially limiting generalizability. Conclusions Results supported the feasibility and efficacy of the proposed IU manipulation for non-clinical sample. Findings parallel clinical research showing that state-IU preceded Worry and Negative Affect states. PMID:27254099

  19. Use of amplicon sequencing to improve sensitivity in PCR-based detection of microbial pathogen in environmental samples.

    PubMed

    Saingam, Prakit; Li, Bo; Yan, Tao

    2018-06-01

    DNA-based molecular detection of microbial pathogens in complex environments is still plagued by sensitivity, specificity and robustness issues. We propose to address these issues by viewing them as inadvertent consequences of requiring specific and adequate amplification (SAA) of target DNA molecules by current PCR methods. Using the invA gene of Salmonella as the model system, we investigated if next generation sequencing (NGS) can be used to directly detect target sequences in false-negative PCR reaction (PCR-NGS) in order to remove the SAA requirement from PCR. False-negative PCR and qPCR reactions were first created using serial dilutions of laboratory-prepared Salmonella genomic DNA and then analyzed directly by NGS. Target invA sequences were detected in all false-negative PCR and qPCR reactions, which lowered the method detection limits near the theoretical minimum of single gene copy detection. The capability of the PCR-NGS approach in correcting false negativity was further tested and confirmed under more environmentally relevant conditions using Salmonella-spiked stream water and sediment samples. Finally, the PCR-NGS approach was applied to ten urban stream water samples and detected invA sequences in eight samples that would be otherwise deemed Salmonella negative. Analysis of the non-target sequences in the false-negative reactions helped to identify primer dime-like short sequences as the main cause of the false negativity. Together, the results demonstrated that the PCR-NGS approach can significantly improve method sensitivity, correct false-negative detections, and enable sequence-based analysis for failure diagnostics in complex environmental samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Luminol testing in detecting modern human skeletal remains: a test on different types of bone tissue and a caveat for PMI interpretation.

    PubMed

    Caudullo, Giorgio; Caruso, Valentina; Cappella, Annalisa; Sguazza, Emanuela; Mazzarelli, Debora; Amadasi, Alberto; Cattaneo, Cristina

    2017-01-01

    When forensic pathologists and anthropologists have to deal with the evaluation of the post-mortem interval (PMI) in skeletal remains, luminol testing is frequently performed as a preliminary screening method. However, the repeatability of this test on the same bone, as well as comparative studies on different bones of the same individual, has never been performed. Therefore, with the aim of investigating the influence that different types of bones may exert on the response to the luminol test, the present study analysed three different skeletal elements (femoral diaphysis, vertebra and cranial vault), gathered from ten recent exhumed skeletons (all with a 20-year PMI). The analysis was performed twice on the same bone after 2 months: the analysis at time 0 concerned the whole bone, whereas the second concerned only a part of the same bone taken during the first test (which already had been broken). The overall results showed different responses, depending on the type of bone and on the integrity of the samples. Negative results at the first analysis (6.6% out of the total of samples) are consistent with what is reported in the literature, whilst at the second analysis, the increase of about 20% of false-negative results highlights that the luminol test ought to be performed with caution in case of broken bones or elements which are taphonomically altered. Results have thus proven that the exposition to environmental agents might result in haemoglobin (Hb) loss, as detected even after only 2 months. The study also focused on the crucial issue of the type of bone subjected to testing, remarking the suitability of the femoral diaphysis (100% of positive responses at the first analysis vs only 18% of false-negative results at the second test, corresponding to 5% of total false-negative results) as opposed to other bone elements that showed a low yield. In particular, the cranial vault gave poor results, with 40% of discrepancy between results from the two analyses, which suggests caution in choosing the type of bone sample to test. In conclusion, luminol testing should be used with caution on bones different from long bones or on non-intact bones.

  1. HIV‑2 antibody detection after indeterminate or negative HIV‑1 Western blot in Cuba, 2005-2008.

    PubMed

    Díaz, Dervel F; Ortiz, Eva; Martín, Dayamí; Nibot, Carmen; Rizo, Adis; Silva, Eladio

    2012-01-01

    INTRODUCTION Differentiating between HIV-1 and HIV-2 infection is the first step to understanding HIV transmission, epidemiology and pathogenesis in geographical areas where both viruses circulate. In Cuba, positive results in mixed HIV-1/2 screening assays are confirmed by HIV-1 Western blot. Indeterminate results constitute the main limitation of this test and HIV-2 infection is among their possible causes; hence the importance of second-stage screening and confirmatory tests for HIV-2 infection. OBJECTIVE Investigate the contribution of HIV-2 antibodies to negative or indeterminate HIV-1 Western blot results in serum samples from 2005 through 2008 in Cuba. METHODS HIV-2 reactivity was studied using the ELISA DAVIH-VIH-2 diagnostic kit (Cuba) in 1723 serum samples with negative or indeterminate results for HIV-1 Western blot from January 2005 through December 2008. Duplicate sera reactive by ELISA were confirmed by HIV-2 Western blot, results interpreted according to WHO criteria. The epidemiological interview established by Cuba's National Program for Prevention and Control Sexually-Transmitted Diseases and HIV/AIDS was applied to HIV-2 Western blot-positive patients. RESULTS Among all sera studied, HIV-2 ELISA identified 12 reactive serum samples (0.70%) and 1711 non-reactive (99.30%). Western blot analysis of the 12 ELISA-reactive samples confirmed two positive samples (16.67%), 4 negative (33.33%) and 6 indeterminate (50%). Positive samples reacted against the p16, p26, gp36, p53, p56, p68 and gp105 proteins. All 12 ELISA-reactive samples belonged to the HIV-1 Western blot indeterminate group. The two HIV-2-positive samples showed well defined reactivity to gp160, p53, p55 and p34 of HIV-1. HIV-1 seroconversion was observed in all 10 remaining samples during serological followup. CONCLUSIONS Two new HIV-2 seropositive cases were diagnosed using DAVIH-VIH-2 and HIV-2 Western blot in indeterminate HIV-1 Western blot samples. Results support the recommendation that HIV-2 Western blot be included in the diagnostic algorithm for HIV-1/2 to followup negative or indeterminate HIV-1 Western blot results. KEYWORDS Diagnosis, laboratory techniques and procedures, antibodies, HIV-2, Western blot, enzyme-linked immunosorbent assay, algorithm, Cuba.

  2. Comparison of a PfHRP2-based rapid diagnostic test and PCR for malaria in a low prevalence setting in rural southern Zambia: implications for elimination.

    PubMed

    Laban, Natasha M; Kobayashi, Tamaki; Hamapumbu, Harry; Sullivan, David; Mharakurwa, Sungano; Thuma, Philip E; Shiff, Clive J; Moss, William J

    2015-01-28

    Rapid diagnostic tests (RDTs) detecting histidine-rich protein 2 (PfHRP2) antigen are used to identify individuals with Plasmodium falciparum infection even in low transmission settings seeking to achieve elimination. However, these RDTs lack sensitivity to detect low-density infections, produce false negatives for P. falciparum strains lacking pfhrp2 gene and do not detect species other than P. falciparum. Results of a PfHRP2-based RDT and Plasmodium nested PCR were compared in a region of declining malaria transmission in southern Zambia using samples from community-based, cross-sectional surveys from 2008 to 2012. Participants were tested with a PfHRP2-based RDT and a finger prick blood sample was spotted onto filter paper for PCR analysis and used to prepare blood smears for microscopy. Species-specific, real-time, quantitative PCR (q-PCR) was performed on samples that tested positive either by microscopy, RDT or nested PCR. Of 3,292 total participants enrolled, 12 (0.4%) tested positive by microscopy and 42 (1.3%) by RDT. Of 3,213 (98%) samples tested by nested PCR, 57 (1.8%) were positive, resulting in 87 participants positive by at least one of the three tests. Of these, 61 tested positive for P. falciparum by q-PCR with copy numbers ≤ 2 x 10(3) copies/μL, 5 were positive for both P. falciparum and Plasmodium malariae and 2 were positive for P. malariae alone. RDT detected 32 (53%) of P. falciparum positives, failing to detect three of the dual infections with P. malariae. Among 2,975 participants enrolled during a low transmission period between 2009 and 2012, sensitivity of the PfHRP2-based RDT compared to nested PCR was only 17%, with specificity of >99%. The pfhrp gene was detected in 80% of P. falciparum positives; however, comparison of copy number between RDT negative and RDT positive samples suggested that RDT negatives resulted from low parasitaemia and not pfhrp2 gene deletion. Low-density P. falciparum infections not identified by currently used PfHRP2-based RDTs and the inability to detect non-falciparum malaria will hinder progress to further reduce malaria in low transmission settings of Zambia. More sensitive and specific diagnostic tests will likely be necessary to identify parasite reservoirs and achieve malaria elimination.

  3. Multiplex identification of sepsis-causing Gram-negative pathogens from the plasma of infected blood.

    PubMed

    Chung, Boram; Park, Chulmin; Cho, Sung-Yeon; Shin, Juyoun; Shin, Sun; Yim, Seon-Hee; Lee, Dong-Gun; Chung, Yeun-Jung

    2018-02-01

    Early and accurate detection of bacterial pathogens in the blood is the most crucial step for sepsis management. Gram-negative bacteria are the most common organisms causing severe sepsis and responsible for high morbidity and mortality. We aimed to develop a method for rapid multiplex identification of clinically important Gram-negative pathogens and also validated whether our system can identify Gram-negative pathogens with the cell-free plasm DNA from infected blood. We designed five MLPA probe sets targeting the genes specific to major Gram-negative pathogens (uidA and lacY for E. coli, ompA for A. baumannii, phoE for K. pneumoniae, and ecfX for P. aeruginosa) and one set targeting the CTX-M group 1 to identify the ESBL producing Gram-negative pathogens. All six target-specific peaks were clearly separated without any non-specific peaks in a multiplex reaction condition. The minimum detection limit was 100 fg of pathogen DNA. When we tested 28 Gram-negative clinical isolates, all of them were successfully identified without any non-specific peaks. To evaluate the clinical applicability, we tested seven blood samples from febrile patients. Three blood culture positive cases showed E. coli specific peaks, while no peak was detected in the other four culture negative samples. This technology can be useful for detection of major sepsis-causing, drug-resistant Gram-negative pathogens and also the major ESBL producing Gram-negatives from the blood of sepsis patients in a clinical setting. This system can help early initiation of effective antimicrobial treatment against Gram-negative pathogens for sepsis patients, which is very crucial for better treatment outcomes. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Negative affect is associated with alcohol, but not cigarette use in heavy drinking smokers.

    PubMed

    Bujarski, Spencer; Ray, Lara A

    2014-12-01

    Co-use of alcohol and cigarettes is highly prevalent, and heavy drinking smokers represent a large and difficult-to-treat subgroup of smokers. Negative affect, including anxiety and depressive symptomatology, has been associated with both cigarette and alcohol use independently, but less is known about the role of negative affect in heavy drinking smokers. Furthermore, while some studies have shown negative affect to precede substance use, a precise biobehavioral mechanism has not been established. The aims of the present study were twofold. First, to test whether negative affect is associated with alcohol and cigarette use in a large community sample of heavy drinking smokers (n=461). And second, to examine craving as a plausible statistical mediator of the association between negative affect and alcohol and/or cigarette use. Hypothesis testing was conducted using a structural equation modeling approach with cross-sectional data. Analysis revealed a significant main effect of negative affect on alcohol use (β=0.210, p<0.05), but not cigarette use (β=0.131, p>0.10) in this sample. Mediational analysis revealed that alcohol craving was a full statistical mediator of this association (p<0.05), such that there was no direct association between negative affect and alcohol use after accounting for alcohol craving. These results are consistent with a negative reinforcement and relief craving models of alcohol use insofar as the experience of negative affect was associated with increased alcohol use, and the relationship was statistically mediated by alcohol craving, presumably to alleviate negative affect. Further longitudinal or experimental studies are warranted to enhance the causal inferences of this mediated effect. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. 9 CFR 113.309 - Bovine Parainfluenza3 Vaccine.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... develop antibody titers of 1:32 or greater by day 6 ±2 days post-challenge. (8) A sequential test... parainfluenza, susceptible calves shall be used as test animals (20 vaccinates and five controls). Blood samples... negative at a 1:2 final serum dilution in a varying serum constant virus neutralization test with less than...

  6. 9 CFR 113.309 - Bovine Parainfluenza3 Vaccine.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... develop antibody titers of 1:32 or greater by day 6 ±2 days post-challenge. (8) A sequential test... parainfluenza, susceptible calves shall be used as test animals (20 vaccinates and five controls). Blood samples... negative at a 1:2 final serum dilution in a varying serum constant virus neutralization test with less than...

  7. Qualitative versus Quantitative Results: An Experimental Introduction to Data Interpretation.

    ERIC Educational Resources Information Center

    Johnson, Eric R.; Alter, Paula

    1989-01-01

    Described is an experiment in which the student can ascertain the meaning of a negative result from a qualitative test by performing a more sensitive quantitative test on the same sample. Methodology for testing urinary glucose with a spectrophotometer at 630 nm and with commercial assaying glucose strips is presented. (MVL)

  8. Antecedents of Psychological Contract Breach: The Role of Job Demands, Job Resources, and Affect

    PubMed Central

    Vantilborgh, Tim; Bidee, Jemima; Pepermans, Roland; Griep, Yannick; Hofmans, Joeri

    2016-01-01

    While it has been shown that psychological contract breach leads to detrimental outcomes, relatively little is known about factors leading to perceptions of breach. We examine if job demands and resources predict breach perceptions. We argue that perceiving high demands elicits negative affect, while perceiving high resources stimulates positive affect. Positive and negative affect, in turn, influence the likelihood that psychological contract breaches are perceived. We conducted two experience sampling studies to test our hypotheses: the first using daily surveys in a sample of volunteers, the second using weekly surveys in samples of volunteers and paid employees. Our results confirm that job demands and resources are associated with negative and positive affect respectively. Mediation analyses revealed that people who experienced high job resources were less likely to report psychological contract breach, because they experienced high levels of positive affect. The mediating role of negative affect was more complex, as it increased the likelihood to perceive psychological contract breach, but only in the short-term. PMID:27171275

  9. Temporal artery biopsy size does not matter.

    PubMed

    Kaptanis, Sarantos; Perera, Joanne K; Halkias, Constantine; Caton, Nadine; Alarcon, Lida; Vig, Stella

    2014-12-01

    This study aimed to clarify whether positive temporal artery biopsies had a greater sample length than negative biopsies in temporal arteritis. It has been suggested that biopsy length should be at least 1 cm to improve diagnostic accuracy. A retrospective review of 149 patients who had 151 temporal artery biopsies was conducted. Twenty biopsies were positive (13.3%), 124 negative (82.1%) and seven samples were insufficient (4.6%). There was no clinically significant difference in the mean biopsy size between positive (0.7 cm) and negative samples (0.65 cm) (t-test: p = .43 NS). Ninety-four patients fulfilled all three ACR criteria prior to biopsy (62.3%) and four patients (2.6%) changed ACR score from 2 to 3 after biopsy. Treatment should not be delayed in anticipation of the biopsy or withheld in the case of a negative biopsy if the patient's symptoms improve. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  10. Antecedents of Psychological Contract Breach: The Role of Job Demands, Job Resources, and Affect.

    PubMed

    Vantilborgh, Tim; Bidee, Jemima; Pepermans, Roland; Griep, Yannick; Hofmans, Joeri

    2016-01-01

    While it has been shown that psychological contract breach leads to detrimental outcomes, relatively little is known about factors leading to perceptions of breach. We examine if job demands and resources predict breach perceptions. We argue that perceiving high demands elicits negative affect, while perceiving high resources stimulates positive affect. Positive and negative affect, in turn, influence the likelihood that psychological contract breaches are perceived. We conducted two experience sampling studies to test our hypotheses: the first using daily surveys in a sample of volunteers, the second using weekly surveys in samples of volunteers and paid employees. Our results confirm that job demands and resources are associated with negative and positive affect respectively. Mediation analyses revealed that people who experienced high job resources were less likely to report psychological contract breach, because they experienced high levels of positive affect. The mediating role of negative affect was more complex, as it increased the likelihood to perceive psychological contract breach, but only in the short-term.

  11. Transactional Patterns of Maternal Depressive Symptoms and Mother-Child Mutual Negativity in an Adoption Sample

    ERIC Educational Resources Information Center

    Roben, Caroline K. P.; Moore, Ginger A.; Cole, Pamela M.; Molenaar, Peter; Leve, Leslie D.; Shaw, Daniel S.; Reiss, David; Neiderhiser, Jenae M.

    2015-01-01

    Transactional models of analysis can examine both moment-to-moment interactions within a dyad and dyadic patterns of influence across time. This study used data from a prospective adoption study to test a transactional model of parental depressive symptoms and mutual negativity between mother and child over time, utilizing contingency analysis of…

  12. The Internal Structure of Positive and Negative Affect: A Confirmatory Factor Analysis of the PANAS

    ERIC Educational Resources Information Center

    Tuccitto, Daniel E.; Giacobbi, Peter R., Jr.; Leite, Walter L.

    2010-01-01

    This study tested five confirmatory factor analytic (CFA) models of the Positive Affect Negative Affect Schedule (PANAS) to provide validity evidence based on its internal structure. A sample of 223 club sport athletes indicated their emotions during the past week. Results revealed that an orthogonal two-factor CFA model, specifying error…

  13. Translating research into practice: targeting negative thinking as a modifiable risk factor for depression prevention in the college student population.

    PubMed

    Buchanan, Jenna L

    2013-06-01

    This article describes the effects of an evidence-based depression prevention intervention on the depressive symptomatology, negative thinking, and self-esteem in college students. A feasibility study was conducted using pre-test post-test design sampling a total of 12 college students. Participants underwent 4-weeks of psychological treatment using Peden's cognitive behavioral group intervention. The Beck Depression Inventory, Crandell Cognitions Inventory, and Rosenberg Self-Esteem Scale were administered at two time points: prior to the intervention (T1) and 4weeks later (T2). Paired t-test analysis found participants had significantly decreased depressive symptoms and negative thinking, and significantly increased self-esteem from T1 to T2. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Characteristics of enzyme-linked immunosorbent assay for detection of IgG antibodies specific to Сhlamydia trachomatis heat shock protein (HSP-60)

    PubMed

    Galkin, O Yu; Besarab, A B; Lutsenko, T N

    2017-01-01

    The goal of this work was to study sensitivity and specificity of the developed ELISA set for the identification of IgG antibodies against Chlamydia trachomatis HSP-60 (using biotinylated tyramine-based signal amplification system). The study was conducted using a panel of characterized sera, as well as two reference ELISA sets of similar purpose. According to the results of ELISA informative value parameters, the ELISA we have developed showed the highest specificity and sensitivity parameters (no false negative or false positive results were registered). In 4 out of 15 intralaboratory panel serum samples initially identified as negative, anti-HSP-60 IgG-antibodies test result in reference ELISA sets upon dilution changed from negative to positive. The nature of titration curves of false negative sera and commercial monoclonal antibodies А57-В9 against C. trachomatis HSP-60 after incubation for 24 h was indicative of the presence of anti-idiotypic antibodies in these samples. Upon sera dilution, idiotypic-anti-idiotypic complexes dissociated, which caused the change of test result. High informative value of the developed ELISA set for identification of IgG antibodies against C. trachomatis HSP-60 has been proven. Anti-idiotypic antibodies possessing C. trachomatis anti-HSP-60 activity and being one of the causes of false negative results of the relevant ELISA-based tests have been identified in blood sera of individuals infected with chlamydial genitourinary infection agents.

  15. Salmonella testing of pooled pre-enrichment broth cultures for screening multiple food samples.

    PubMed

    Price, W R; Olsen, R A; Hunter, J E

    1972-04-01

    A method has been described for testing multiple food samples for Salmonella without loss in sensitivity. The method pools multiple pre-enrichment broth cultures into single enrichment broths. The subsequent stages of the Salmonella analysis are not altered. The method was found applicable to several dry food materials including nonfat dry milk, dried egg albumin, cocoa, cottonseed flour, wheat flour, and shredded coconut. As many as 25 pre-enrichment broth cultures were pooled without apparent loss in the sensitivity of Salmonella detection as compared to individual sample analysis. The procedure offers a simple, yet effective, way to increase sample capacity in the Salmonella testing of foods, particularly where a large proportion of samples ordinarily is negative. It also permits small portions of pre-enrichment broth cultures to be retained for subsequent individual analysis if positive tests are found. Salmonella testing of pooled pre-enrichment broths provides increased consumer protection for a given amount of analytical effort as compared to individual sample analysis.

  16. Associations of acoustically measured tongue/jaw movements and portion of time speaking with negative symptom severity in patients with schizophrenia in Italy and the United States.

    PubMed

    Bernardini, Francesco; Lunden, Anya; Covington, Michael; Broussard, Beth; Halpern, Brooke; Alolayan, Yazeed; Crisafio, Anthony; Pauselli, Luca; Balducci, Pierfrancesco M; Capulong, Leslie; Attademo, Luigi; Lucarini, Emanuela; Salierno, Gianfranco; Natalicchi, Luca; Quartesan, Roberto; Compton, Michael T

    2016-05-30

    This is the first cross-language study of the effect of schizophrenia on speech as measured by analyzing phonetic parameters with sound spectrography. We hypothesized that reduced variability in pitch and formants would be correlated with negative symptom severity in two samples of patients with schizophrenia, one from Italy, and one from the United States. Audio recordings of spontaneous speech were available from 40 patients. From each speech sample, a file of F0 (pitch) and formant values (F1 and F2, resonance bands indicating the moment-by-moment shape of the oral cavity), and the portion of the recording in which there was speaking ("fraction voiced," FV), was created. Correlations between variability in the phonetic indices and negative symptom severity were tested and further examined using regression analyses. Meaningful negative correlations between Scale for the Assessment of Negative Symptoms (SANS) total score and standard deviation (SD) of F2, as well as variability in pitch (SD F0) were observed in the Italian sample. We also found meaningful associations of SANS affective flattening and SANS alogia with SD F0, and of SANS avolition/apathy and SD F2 in the Italian sample. In both samples, FV was meaningfully correlated with SANS total score, avolition/apathy, and anhedonia/asociality. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Antibacterial Efficacy of Tender Coconut Water (Cocos nucifera L) on Streptococcus mutans: An In-Vitro Study

    PubMed Central

    Rukmini, J. N.; Manasa, Sunkari; Rohini, Chenna; Sireesha, Lavanya Putchla; Ritu, Sachan; Umashankar, G. K.

    2017-01-01

    Objective: The antibacterial property of coconut, the presence of lauric acid, and the ability to extract antimicrobial peptides Cn-AMP (1, 2, and 3) from tender coconut water has drawn attention on its effectiveness in normal consumption. An in-vitro experimental study was conducted to evaluate the antimicrobial efficacy of tender coconut water in its natural state on Streptococcus mutans. Materials and Methods: Fresh tender coconut water and pasteurized tender coconut water were taken as test samples, dimethyl formamide was used as the negative control, and 0.2% chlorhexidine was used as the positive control. Pure strain of S. mutans (MTCC 890) was used for determining the antibacterial effects. The test samples along with the controls were subjected to antimicrobial sensitivity test procedure and the zone of inhibition was examined. Kruskal–Wallis test was used to check for any significant differences in the antibacterial efficacy between the samples. Result: There was no zone of inhibition with the tender coconut water, fresh and pasteurised, and negative control (dimethyl formamide). Zone of inhibition was seen in positive control (0.2% Chlorhexidine). Conclusion: No antimicrobial activity was demonstrated with tender coconut water in its normal state (in vitro). PMID:28462183

  18. Antibacterial Efficacy of Tender Coconut Water (Cocos nucifera L) on Streptococcus mutans: An In-Vitro Study.

    PubMed

    Rukmini, J N; Manasa, Sunkari; Rohini, Chenna; Sireesha, Lavanya Putchla; Ritu, Sachan; Umashankar, G K

    2017-01-01

    The antibacterial property of coconut, the presence of lauric acid, and the ability to extract antimicrobial peptides Cn-AMP (1, 2, and 3) from tender coconut water has drawn attention on its effectiveness in normal consumption. An in-vitro experimental study was conducted to evaluate the antimicrobial efficacy of tender coconut water in its natural state on Streptococcus mutans . Fresh tender coconut water and pasteurized tender coconut water were taken as test samples, dimethyl formamide was used as the negative control, and 0.2% chlorhexidine was used as the positive control. Pure strain of S. mutans (MTCC 890) was used for determining the antibacterial effects. The test samples along with the controls were subjected to antimicrobial sensitivity test procedure and the zone of inhibition was examined. Kruskal-Wallis test was used to check for any significant differences in the antibacterial efficacy between the samples. There was no zone of inhibition with the tender coconut water, fresh and pasteurised, and negative control (dimethyl formamide). Zone of inhibition was seen in positive control (0.2% Chlorhexidine). No antimicrobial activity was demonstrated with tender coconut water in its normal state ( in vitro ).

  19. Preliminary Validation of a New Measure of Negative Response Bias: The Temporal Memory Sequence Test.

    PubMed

    Hegedish, Omer; Kivilis, Naama; Hoofien, Dan

    2015-01-01

    The Temporal Memory Sequence Test (TMST) is a new measure of negative response bias (NRB) that was developed to enrich the forced-choice paradigm. The TMST does not resemble the common structure of forced-choice tests and is presented as a temporal recall memory test. The validation sample consisted of 81 participants: 21 healthy control participants, 20 coached simulators, and 40 patients with acquired brain injury (ABI). The TMST had high reliability and significantly high positive correlations with the Test of Memory Malingering and Word Memory Test effort scales. Moreover, the TMST effort scales exhibited high negative correlations with the Glasgow Coma Scale, thus validating the previously reported association between probable malingering and mild traumatic brain injury. A suggested cutoff score yielded acceptable classification rates in the ABI group as well as in the simulator and control groups. The TMST appears to be a promising measure of NRB detection, with respectable rates of reliability and construct and criterion validity.

  20. Investigation of the Applicability of a Rapid Diagnosis Test in the Diagnosis of Cystic Echinococcosis.

    PubMed

    Ertuğ, Sema; Çalışkan, Serçin Özlem; Malatyalı, Erdoğan; Ertabaklar, Hatice

    2018-05-21

    Echinococcus granulosus, the etiological agent of cystic echinococcosis (CE) in humans and livestock, is a widely distributed zoonotic pathogen tapeworm. The infection is transmitted to humans by the ingestion of E. granulosus eggs released in the feces of definitive hosts such as dogs. The larval stage of the parasite develops a slowly enlarging cyst in the visceral organs, particularly in the liver and/or lung. The aim of the present study was to evaluate the diagnostic value of an immunochromatographic test (ICT) for CE. A total of 50 sera from surgically and/or pathologically confirmed patients with CE were included in the study as the study group; the control group comprised patients who tested negative for enzyme-linked immunosorbent assay (ELISA). Sera were selected from the collection at Adnan Menderes University, Faculty of Medicine, Parasitology Laboratory, by simple random sampling. The collection included sera obtained between 2010 and 2014; antibody titers of each serum sample were determined using in-house ELISA, before storage at -20°C. The presence of E. granulosus antibody in the sera was determined using a commercially available ICT (VIRAPID® HYDATIDOSIS) kit method. In the study group (E. granulosus-confirmed cases), two (4%) of the 50 sera were negative and 48 (96%) were positive with ICT. In the control group (ELISA-negative), all were negative with ICT. The rapid diagnostic test has been evaluated as a practical, easy-to-use method for detecting CE, and it can be used as a screening test in routine diagnosis and research.

  1. Direct detection of methicillin-resistant Staphylococcus aureus from blood cultures using an immunochromatographic immunoassay-based MRSA rapid kit for the detection of penicillin-binding protein 2a.

    PubMed

    Shin, Kyeong Seob; Song, Hyung Geun; Kim, Haejung; Yoon, Sangsun; Hong, Seung Bok; Koo, Sun Hoe; Kim, Jimyung; Kim, Jongwan; Roh, Kyoung Ho

    2010-07-01

    Using an EZ-Step MRSA rapid kit, a novel screening test for methicillin-resistant Staphylococcus aureus (MRSA) that detects penicillin-binding protein 2a, 34 of 36 MRSA-positive clinical blood culture samples were positive on direct testing (sensitivity, 94.4%), whereas 21 of 21 methicillin-susceptible S. aureus-positive samples were negative (specificity, 100%).

  2. The relative utility of the autologous control and the antiglobulin test phase of the crossmatch.

    PubMed

    Perkins, J T; Arruza, M; Fong, K; Sosler, S D; Saporito, C

    1990-01-01

    A retrospective study of pretransfusion testing records compared the utility of the antiglobulin test (AGT) phase of the crossmatch and the autologous control (autocontrol) for detecting clinically significant alloimmunization to red cells (RBCs). Of 110,780 consecutive crossmatches, 141 were positive after a negative antibody screening test; only 4 of these were due to alloantibodies of potential clinical significance, for a predictive value of a positive AGT crossmatch, after a negative antibody screen, of 2.8 percent (4/141). The frequency of potentially shortened RBC survival was 1 in 27,685 units crossmatched. During a similar period, 56,090 autocontrols were performed with the antibody screen. The autocontrol was positive on 902 samples in which the antibody screen was negative. Antibody identification performed in 684 cases generally yielded only cold or warm autoagglutinins. In 96 cases, some form of alloantibody was detected, but only 25 had potential clinical significance by our criteria. Eight of these alloantibodies had concurrently caused in vivo sensitization of RBCs and were classified as delayed hemolytic transfusion reactions. The predictive value of the autocontrol, calculated as the number of significant alloantibodies detected in autocontrol-positive, antibody-screen-negative samples, was 3.6 percent (25/684). Inspection of these cases revealed 11 in which shortened RBC survival might have resulted if the serologic abnormality had not been detected. Thus, the autocontrol had a slightly greater yield of clinically significant findings than the AGT crossmatch.(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Variations in the detection of anti-PEDV antibodies in serum samples using three diagnostic tests - short communication.

    PubMed

    Plut, Jan; Toplak, Ivan; Štukelj, Marina

    2018-06-01

    Over the last few years several porcine epidemic diarrhoea (PED) outbreaks have been discovered in Europe including the first PED case in Slovenia in January 2015. The aim of this study was to determine when PED virus (PEDV) infection started in Slovenia. Serum samples collected between 2012 and 2016 were tested. Three hundred and seventy-five serum samples were collected from 132 Slovenian small, one-site pig farms. Samples were tested for PEDV antibodies utilising three different serological methods: commercially-available indirect ELISA, in-house blocking ELISA test and Immunoperoxidase Monolayer Assay (IPMA) test. One hundred and seventy (45.33%) tested samples were found positive by the commercially-available ELISA test kit, and 10 (5.68%) of these 170 samples found positive were positive by the in-house blocking ELISA. Only these 10 samples were collected from a farm where clinical signs of PED infection had been observed and PEDV was confirmed by RT-PCR methodology; the other 160 samples were collected randomly. Thirty-two samples with the highest S/P value obtained with the commercial ELISA were all negative with IPMA. Reasons for the high variance in the results obtained remain unclear; more research is required to ensure higher sensitivity and specificity in terms of PEDV antibody tests and other PED diagnostic methods.

  4. Evaluation of a quantitative H2S MPN test for fecal microbes analysis of water using biochemical and molecular identification.

    PubMed

    McMahan, Lanakila; Grunden, Amy M; Devine, Anthony A; Sobsey, Mark D

    2012-04-15

    The sensitivity and specificity of the H(2)S test to detect fecal bacteria in water has been variable and uncertain in previous studies, partly due to its presence-absence results. Furthermore, in groundwater samples false-positive results have been reported, with H(2)S-positive samples containing no fecal coliforms or Escherichia coli. False-negative results also have been reported in other studies, with H(2)S-negative samples found to contain E. coli. Using biochemical and molecular methods and a novel quantitative test format, this research identified the types and numbers of microbial community members present in natural water samples, including fecal indicators and pathogens as well as other bacteria. Representative water sources tested in this study included cistern rainwater, a protected lake, and wells in agricultural and forest settings. Samples from quantitative H(2)S tests of water were further cultured for fecal bacteria by spread plating onto the selective media for detection and isolation of Aeromonas spp., E. coli, Clostridium spp., H(2)S-producers, and species of Salmonella and Shigella. Isolates were then tested for H(2)S production, and identified to the genus and species level using biochemical methods. Terminal Restriction Fragment Length Polymorphisms (TRFLP) was the molecular method employed to quantitatively characterize microbial community diversity. Overall, it was shown that water samples testing positive for H(2)S bacteria also had bacteria of likely fecal origin and waters containing fecal pathogens also were positive for H(2)S bacteria. Of the microorganisms isolated from natural water, greater than 70 percent were identified using TRFLP analysis to reveal a relatively stable group of organisms whose community composition differed with water source and over time. These results further document the validity of the H(2)S test for detecting and quantifying fecal contamination of water. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Usefulness of interferon-γ release assay for the diagnosis of sputum smear-negative pulmonary and extra-pulmonary TB in Zhejiang Province, China.

    PubMed

    Ji, Lei; Lou, Yong-Liang; Wu, Zhong-Xiu; Jiang, Jin-Qin; Fan, Xing-Li; Wang, Li-Fang; Liu, Xiao-Xiang; Du, Peng; Yan, Jie; Sun, Ai-Hua

    2017-09-01

    Quick diagnosis of smear-negative pulmonary tuberculosis (TB) and extra-pulmonary TB are urgently needed in clinical diagnosis. Our research aims to investigate the usefulness of the interferon-γ release assay (IGRA) for the diagnosis of smear-negative pulmonary and extra-pulmonary TB. We performed TB antibody and TB-IGRA tests on 389 pulmonary TB patients (including 120 smear-positive pulmonary TB patients and 269 smear-negative pulmonary TB patients), 113 extra-pulmonary TB patients, 81 patients with other pulmonary diseases and 100 healthy controls. Blood samples for the TB-Ab test and the TB-IGRA were collected, processed, and interpreted according to the manufacturer's protocol. The detection ratio of smear-positive pulmonary TB patients and smear-negative pulmonary TB patients were 90.8% (109 of 120) and 89.6% (241 of 269), respectively. There was no statistically significant difference of its performance between these two sample sets (P > 0.05). The detection ratio of positive TB patients and extra-pulmonary TB patients were 90.0% (350 of 389) and 87.6% (99 of 113), respectively, which was not significantly different (P > 0.05). In this work, the total detection ratio using TB-IGRA was 89.4%, therefore TB-IGRA has diagnostic values in smear-negative pulmonary TB and extra-pulmonary TB diagnosis.

  6. Detection of Zika Virus in April 2013 Patient Samples, Rio de Janeiro, Brazil

    PubMed Central

    Borges dos Santos, Maria A.; Cerbino-Neto, José; Buonora, Sibelle N.; Souza, Thiago M.L.; de Oliveira, Raquel V.C.; Vizzoni, Alexandre; Barbosa-Lima, Giselle; Vieira, Yasmine R.; Silva de Lima, Marcondes; Hökerberg, Yara H. M.

    2017-01-01

    We tested 210 dengue virus‒negative samples collected from febrile patients during a dengue virus type 4 outbreak in Rio de Janeiro in April 2013 and found 3 samples positive for Zika virus. Our findings support previously published entomological data suggesting Zika virus was introduced into Brazil during October 2012–May 2013. PMID:28953451

  7. Fronto-temporal connectivity predicts cognitive empathy deficits and experiential negative symptoms in schizophrenia.

    PubMed

    Abram, Samantha V; Wisner, Krista M; Fox, Jaclyn M; Barch, Deanna M; Wang, Lei; Csernansky, John G; MacDonald, Angus W; Smith, Matthew J

    2017-03-01

    Impaired cognitive empathy is a core social cognitive deficit in schizophrenia associated with negative symptoms and social functioning. Cognitive empathy and negative symptoms have also been linked to medial prefrontal and temporal brain networks. While shared behavioral and neural underpinnings are suspected for cognitive empathy and negative symptoms, research is needed to test these hypotheses. In two studies, we evaluated whether resting-state functional connectivity between data-driven networks, or components (referred to as, inter-component connectivity), predicted cognitive empathy and experiential and expressive negative symptoms in schizophrenia subjects. Study 1: We examined associations between cognitive empathy and medial prefrontal and temporal inter-component connectivity at rest using a group-matched schizophrenia and control sample. We then assessed whether inter-component connectivity metrics associated with cognitive empathy were also related to negative symptoms. Study 2: We sought to replicate the connectivity-symptom associations observed in Study 1 using an independent schizophrenia sample. Study 1 results revealed that while the groups did not differ in average inter-component connectivity, a medial-fronto-temporal metric and an orbito-fronto-temporal metric were related to cognitive empathy. Moreover, the medial-fronto-temporal metric was associated with experiential negative symptoms in both schizophrenia samples. These findings support recent models that link social cognition and negative symptoms in schizophrenia. Hum Brain Mapp 38:1111-1124, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  8. Phytophthora capsici Epidemic Dispersion on Commercial Pepper Fields in Aguascalientes, Mexico

    PubMed Central

    Zapata-Vázquez, Adrián; Sánchez-Sánchez, Mario; del-Río-Robledo, Alicia; Silos-Espino, Héctor; Perales-Segovia, Catarino; Flores-Benítez, Silvia; González-Chavira, Mario Martín; Valera-Montero, Luis Lorenzo

    2012-01-01

    Chili pepper blight observed on pepper farms from north Aguascalientes was monitored for the presence of Phytophthora capsici during 2008–2010. Initially, ELISA tests were directed to plant samples from greenhouses and rustic nurseries, showing an 86% of positive samples. Later, samples of wilted plants from the farms during the first survey were tested with ELISA. The subsequent survey on soil samples included mycelia isolation and PCR amplification of a 560 bp fragment of ITS-specific DNA sequence of P. capsici. Data was analyzed according to four geographical areas defined by coordinates to ease the dispersal assessment. In general, one-third of the samples from surveyed fields contained P. capsici, inferring that this may be the pathogen responsible of the observed wilt. Nevertheless, only five sites from a total of 92 were consistently negative to P. capsici. The presence of this pathogen was detected through ELISA and confirmed through PCR. The other two-thirds of the negative samples may be attributable to Fusarium and Rhizoctonia, both isolated instead of Phytophthora in these areas. Due to these striking results, this information would be of interest for local plant protection committees and farmers to avoid further dispersal of pathogens to new lands. PMID:22629131

  9. Assessing Immunity to Rubella Virus: a Plea for Standardization of IgG (Immuno)assays

    PubMed Central

    Bouthry, Elise; Huzly, Daniela; Ogee-Nwankwo, Adaeze; Hao, LiJuan; Adebayo, Adebola; Icenogle, Joseph; Sarasini, Antonella; Revello, Maria Grazia; Grangeot-Keros, Liliane

    2016-01-01

    Immunity to rubella virus (RV) is commonly determined by measuring specific immunoglobulin G (RV IgG). However, RV IgG results and their interpretation may vary, depending on the immunoassay, even though most commercial immunoassays (CIAs) have been calibrated against an international standard and results are reported in international units per milliliter. A panel of 322 sera collected from pregnant women that tested negative or equivocal for RV IgG in a prior test (routine screening) was selected. This panel was tested with two reference tests, immunoblotting (IB) and neutralization (Nt), and with 8 CIAs widely used in Europe. IB and Nt gave concordant results on 267/322 (82.9%) sera. Of these, 85 (26.4%) sera were negative and 182 (56.5%) sera were positive for both tests. All 85 IB/Nt-negative samples were classified as negative with all CIAs. Of the 182 IB/Nt-positive samples, 25.3 to 61.5% were classified as equivocal and 6 to 64.8% were classified as positive with the CIAs. Wide variations in titers in international units per milliliter were observed. In our series, more than half of the women considered susceptible to RV based on CIA results tested positive for RV antibodies by IB/Nt. Our data suggest that (i) sensitivity of CIAs could be increased by considering equivocal results as positive and (ii) the definition of immunity to RV as the 10-IU/ml usual cutoff as well as the use of quantitative results for clinical decisions may warrant reconsideration. A better standardization of CIAs for RV IgG determination is needed. PMID:27147722

  10. Assessing Immunity to Rubella Virus: a Plea for Standardization of IgG (Immuno)assays.

    PubMed

    Bouthry, Elise; Furione, Milena; Huzly, Daniela; Ogee-Nwankwo, Adaeze; Hao, LiJuan; Adebayo, Adebola; Icenogle, Joseph; Sarasini, Antonella; Revello, Maria Grazia; Grangeot-Keros, Liliane; Vauloup-Fellous, Christelle

    2016-07-01

    Immunity to rubella virus (RV) is commonly determined by measuring specific immunoglobulin G (RV IgG). However, RV IgG results and their interpretation may vary, depending on the immunoassay, even though most commercial immunoassays (CIAs) have been calibrated against an international standard and results are reported in international units per milliliter. A panel of 322 sera collected from pregnant women that tested negative or equivocal for RV IgG in a prior test (routine screening) was selected. This panel was tested with two reference tests, immunoblotting (IB) and neutralization (Nt), and with 8 CIAs widely used in Europe. IB and Nt gave concordant results on 267/322 (82.9%) sera. Of these, 85 (26.4%) sera were negative and 182 (56.5%) sera were positive for both tests. All 85 IB/Nt-negative samples were classified as negative with all CIAs. Of the 182 IB/Nt-positive samples, 25.3 to 61.5% were classified as equivocal and 6 to 64.8% were classified as positive with the CIAs. Wide variations in titers in international units per milliliter were observed. In our series, more than half of the women considered susceptible to RV based on CIA results tested positive for RV antibodies by IB/Nt. Our data suggest that (i) sensitivity of CIAs could be increased by considering equivocal results as positive and (ii) the definition of immunity to RV as the 10-IU/ml usual cutoff as well as the use of quantitative results for clinical decisions may warrant reconsideration. A better standardization of CIAs for RV IgG determination is needed. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  11. [Diagnostic accuracy of fine needle aspiration cytology in parotid tumours].

    PubMed

    Zerpa Zerpa, Vanessa; Cuesta Gonzáles, Maria Teresa; Agostini Porras, Gabriela; Marcano Acuña, Martin; Estellés Ferriol, Enrique; Dalmau Galofre, José

    2014-01-01

    Fine needle aspiration cytology (FNAC) is a globally accepted technique in the preoperative evaluations of head and neck tumours; however, the effectiveness in the interpretation of salivary glands neoplastic lesions is still controversial. The objective of this study consisted of assessing the efficacy of FNAC in preoperative diagnosis of parotid tumours. This retrospective study was conducted using 93 patient samples with parotid gland tumoral pathology, treated at the Otorhinolaryngology Department in our institution during the 2007-2011 period. Preoperative FNAC was employed and the patients subsequently submitted to surgical excision with histopathological diagnosis of the specimen. Cytology results were classified as negative for malignancy, positive for malignancy or insufficient sample, and later compared with the definitive histological diagnosis. The mean age of the studied sample was 52.9 years (range: 11 to 88 years); 55.9% were men. The FNAC showed significant sensitivity of 57.1%, with a specificity of 95.1%, for detecting malignancy in parotid gland tumours. The positive and negative predictive values for malignancy were 50 and 96.3%, respectively. FNAC is considered a simple test but of limited use for diagnostic guidance in tumour pathology of the parotid gland in our environment, mainly because of its low sensitivity. However, the high specificity and high negative predictive value of FNAC makes it a more accurate test in benign or negative result cases. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  12. Development and first evaluation of a novel multiplex real-time PCR on whole blood samples for rapid pathogen identification in critically ill patients with sepsis.

    PubMed

    van de Groep, Kirsten; Bos, Martine P; Savelkoul, Paul H M; Rubenjan, Anna; Gazenbeek, Christel; Melchers, Willem J G; van der Poll, Tom; Juffermans, Nicole P; Ong, David S Y; Bonten, Marc J M; Cremer, Olaf L

    2018-04-26

    Molecular tests may enable early adjustment of antimicrobial therapy and be complementary to blood culture (BC) which has imperfect sensitivity in critically ill patients. We evaluated a novel multiplex real-time PCR assay to diagnose bloodstream pathogens directly in whole blood samples (BSI-PCR). BSI-PCR included 11 species- and four genus-specific PCRs, a molecular Gram-stain PCR, and two antibiotic resistance markers. We collected 5 mL blood from critically ill patients simultaneously with clinically indicated BC. Microbial DNA was isolated using the Polaris method followed by automated DNA extraction. Sensitivity and specificity were calculated using BC as reference. BSI-PCR was evaluated in 347 BC-positive samples (representing up to 50 instances of each pathogen covered by the test) and 200 BC-negative samples. Bacterial species-specific PCR sensitivities ranged from 65 to 100%. Sensitivity was 26% for the Gram-positive PCR, 32% for the Gram-negative PCR, and ranged 0 to 7% for yeast PCRs. Yeast detection was improved to 40% in a smaller set-up. There was no overall association between BSI-PCR sensitivity and time-to-positivity of BC (which was highly variable), yet Ct-values were lower for true-positive versus false-positive PCR results. False-positive results were observed in 84 (4%) of the 2200 species-specific PCRs in 200 culture-negative samples, and ranged from 0 to 6% for generic PCRs. Sensitivity of BSI-PCR was promising for individual bacterial pathogens, but still insufficient for yeasts and generic PCRs. Further development of BSI-PCR will focus on improving sensitivity by increasing input volumes and on subsequent implementation as a bedside test.

  13. Rapid and sensitive approach to simultaneous detection of genomes of hepatitis A, B, C, D and E viruses.

    PubMed

    Kodani, Maja; Mixson-Hayden, Tonya; Drobeniuc, Jan; Kamili, Saleem

    2014-10-01

    Five viruses have been etiologically associated with viral hepatitis. Nucleic acid testing (NAT) remains the gold standard for diagnosis of viremic stages of infection. NAT methodologies have been developed for all hepatitis viruses; however, a NAT-based assay that can simultaneously detect all five viruses is not available. We designed TaqMan card-based assays for detection of HAV RNA, HBV DNA, HCV RNA, HDV RNA and HEV RNA. The performances of individual assays were evaluated on TaqMan Array Cards (TAC) for detecting five viral genomes simultaneously. Sensitivity and specificity were determined by testing 329 NAT-tested clinical specimens. All NAT-positive samples for HCV (n = 32), HDV (n = 28) and HEV (n = 14) were also found positive in TAC (sensitivity, 100%). Forty-three of 46 HAV-NAT positive samples were also positive in TAC (sensitivity, 94%), while 36 of 39 HBV-NAT positive samples were positive (sensitivity, 92%). No false-positives were detected for HBV (n = 32), HCV (n = 36), HDV (n = 30), and HEV (n = 31) NAT-negative samples (specificity 100%), while 38 of 41 HAV-NAT negative samples were negative by TAC (specificity 93%). TAC assay was concordant with corresponding individual NATs for hepatitis A-E viral genomes and can be used for their detection simultaneously. The TAC assay has potential for use in hepatitis surveillance, for screening of donor specimens and in outbreak situations. Wider availability of TAC-ready assays may allow for customized assays, for improving acute jaundice surveillance and for other purposes for which there is need to identify multiple pathogens rapidly. Published by Elsevier B.V.

  14. Application of paper spray ionization for explosives analysis.

    PubMed

    Tsai, Chia-Wei; Tipple, Christopher A; Yost, Richard A

    2017-10-15

    A desired feature in the analysis of explosives is to decrease the time of the entire analysis procedure, including sampling. A recently utilized ambient ionization technique, paper spray ionization (PSI), provides the possibility of combining sampling and ionization. However, an interesting phenomenon that occurs in generating negatively charged ions pose some challenges in applying PSI to explosives analysis. The goal of this work is to investigate the possible solutions for generating explosives ions in negative mode PSI. The analysis of 2,4,6-trinitrotoluene (TNT), pentaerythritol tetranitrate (PETN), octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), and 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) was performed. Several solvent systems with different surface tensions and additives were compared to determine their effect on the ionization of explosives. The solvents tested include tert-butanol, isopropanol, methanol, and acetonitrile. The additives tested were carbon tetrachloride and ammonium nitrate. Of the solvents tested, isopropanol yielded the best results. In addition, adding ammonium nitrate to the isopropanol enhanced the analyte signal. Experimentally determined limits of detection (LODs) as low as 0.06 ng for PETN, on paper, were observed with isopropanol and the addition of 0.4 mM ammonium nitrate as the spray solution. In addition, the explosive components of two plastic explosive samples, Composition 4 and Semtex, were successfully analyzed via surface sampling when using the developed method. The analysis of explosives using PSI-MS in negative ion mode was achieved. The addition of ammonium nitrate to isopropanol, in general, enhanced the analyte signal and yielded better ionization stability. Real-world explosive samples were analyzed, which demonstrates one of the potential applications of PSI-MS analysis. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Relationships between perceived STD-related stigma, STD-related shame and STD screening among a household sample of adolescents.

    PubMed

    Cunningham, Shayna D; Kerrigan, Deanna L; Jennings, Jacky M; Ellen, Jonathan M

    2009-12-01

    Important barriers to STD testing may include individuals' perceptions of STD-related stigma (negative societal attitudes toward STD infection) and expectations of STD-related shame (negative personal feelings) that would result from a positive STD test. Obtaining a clear understanding of the relationship between STD-related stigma, STD-related shame and STD testing may help inform programs and policies aimed at reducing STD transmission. Measures derived from previously published scales were used to assess perceived STD-related stigma, anticipated STD-related shame and receipt of an STD test in the past year in an urban, household sample of 594 sexually active 15-24-year-olds interviewed in 2004-2007. Logistic regression was used to examine associations between recent STD testing and perceived stigma, shame and other participant characteristics. Thirty-seven percent of males and 70% of females reporting having had an STD test in the past year; the largest proportions of tests (42% among males and 59% among females) had occurred in the context of a routine health care visit, not because adolescents had had disease symptoms or were concerned about exposure to infection. For both males and females, the level of STD-related stigma was negatively associated with the odds of having been tested (odds ratio, 0.5 for each). STD-related shame was not related to STD testing. Adolescents who view STDs as stigmatizing have a reduced likelihood of being screened, but it is unclear whether this relationship reflects their care seeking or providers' practice of offering STD screening at a routine health visit.

  16. Helicobacter-negative gastritis: polymerase chain reaction for Helicobacter DNA is a valuable tool to elucidate the diagnosis.

    PubMed

    Kiss, S; Zsikla, V; Frank, A; Willi, N; Cathomas, G

    2016-04-01

    Helicobacter-negative gastritis has been increasingly reported. Molecular techniques as the polymerase chain reaction (PCR) may detect bacterial DNA in histologically negative gastritis. To evaluate of Helicobacter PCR in gastric biopsies for the daily diagnostics of Helicobacter-negative gastritis. Over a 5-year period, routine biopsies with chronic gastritis reminiscent of Helicobacter infection, but negative by histology, were tested by using a H. pylori specific PCR. Subsequently, PCR-negative samples were re-evaluated using PCR for other Helicobacter species. Of the 9184 gastric biopsies, 339 (3.7%) with histological-negative gastritis and adequate material were forwarded to PCR analysis for H. pylori and 146 (43.1%) revealed a positive result. In 193 H. pylori DNA-negative biopsies, re-analysis using PCR primers for other Helicobacter species, revealed further 23 (11.9%) positive biopsies, including 4 (2.1%) biopsies with H. heilmannii sensu lato. PCR-positive biopsies showed a higher overall inflammatory score, more lymphoid follicles/aggregates and neutrophils (P < 0.05). No Helicobacter DNA was found in control biopsies of 48 patients with neither primer set (P < 0.0001). In 274 patients with an endoscopic description, detection of H. pylori DNA was associated with ulcers and erosions (P < 0.01). Over all, in 339 histologically-negative gastric biopsies, Helicobacter DNA was detected in 169 (49.9%) samples with at least one primer set. Molecular testing offers a sensitive and specific diagnosis to a selected group of patients, in whom adequate searches for bacteria by conventional histology have resulted in the unsatisfactory diagnosis of H. pylori-negative gastritis. © 2016 John Wiley & Sons Ltd.

  17. Development and evaluation of a truncated recombinant NS3 antigen-based indirect ELISA for detection of pestivirus antibodies in sheep and goats.

    PubMed

    Kalaiyarasu, Semmannan; Mishra, Niranjan; Rajukumar, Katherukamem; Nema, Ram Kumar; Behera, Sthita Pragnya

    2015-01-01

    The aim of this study was to develop an indirect ELISA using the helicase domain of bovine viral diarrhoea virus (BVDV) NS3 protein instead of full-length NS3 protein for detection of BVDV and BDV antibodies in sheep and goats and its validation by comparing its sensitivity and specificity with virus neutralization test (VNT) as the reference test. The purified 50 kDa recombinant NS3 protein was used as the coating antigen in the ELISA. The optimal concentration of antigen was 320 ng/well at a serum dilution of 1:20 and the optimal positive cut-off optical density value was 0.40 based on test results of 418 VNT negative sheep and goat sera samples. When 569 serum samples from sheep (463) and goats (106) were tested, the ELISA showed a sensitivity of 91.71% and specificity of 94.59% with BVDV VNT. A good correlation (93.67%) was observed between the two tests. It showed a sensitivity of 85% and specificity of 86.6% with VNT in detecting BDV antibody positive or negative samples. This study demonstrates the efficacy of truncated recombinant NS3 antigen based ELISA for seroepidemiological study of pestivirus infection in sheep and goats.

  18. Molecular Detection of Brucella spp. from Milk of Seronegative Cows from Some Selected Area in Bangladesh

    PubMed Central

    Islam, Md. Ariful; Khatun, Mst. Minara; Saha, Sukumar; Basir, Md. Samiul; Hasan, Md- Mahmodul

    2018-01-01

    Brucellosis is endemic in Bangladesh both in humans and in animals. A number of reasons complicate the diagnosis, as bovine brucellosis can be diagnosed by various serological tests. But the tests have a limitation; when the organism remains intracellular, the disease goes into chronic stage and the antibody titres may decline. The present study was conducted for isolation and detection of Brucella spp. by polymerase chain reaction (PCR) from seronegative cows. A total of 360 dairy cows from three geographical regions were screened serologically by Rose Bengal Plate Test (RBPT) where 24 samples were serologically positive and the rest of the samples were serologically negative. Among the 24 seropositive individuals, 11 were culture positive and 6 were culture positive from serologically negative dairy cows. The overall seroprevalence of brucellosis in cattle was 6.6% and in disease condition a higher prevalence was recorded in abortion (28.07%) followed by infertility (13.33%). To confirm the Brucella spp. in seronegative dairy cattle, the isolates were extracted and PCR was conducted, which produced 905 bp amplicon size of 6 Brucella spp. from milk sample. So, for the detection or eradication of brucellosis, a bacteriological test and a PCR technique should be performed with the serological test of milk. PMID:29568653

  19. [Trypanosoma cruzi in triatomines from Nuevo Leon, Mexico].

    PubMed

    Molina-Garza, Zinnia Judith; Rosales-Encina, José Luis; Galaviz-Silva, Lucio; Molina-Garza, Daniel

    2007-01-01

    To determine the prevalence of Trypanosoma cruzi in triatomines from Nuevo León using the standardization of an improved enzyme-linked immunosorbent assay test. From July to September 2005, 52 triatomines were captured in General Terán, a municipality located in Nuevo León. They were analyzed using optical microscopy (OM) and a polymerase chain reaction (PCR), as standards of reference, to develop a technique for detecting the parasite using enzyme-linked immunosorbent assay (ELISA). Using OM and PCR, 31 triatomines were found to be positive and 21 negative. Using ELISA, 27 samples were identified as positive and 25 negative (specificity 100%, sensitivity 87%, negative predictive value 84%, and positive predictive value 100%). The prevalence of infected triatomines was 59.61% with OM and PCR, and 51.92% with ELISA. Our data confirm that the ELISA assay in triatomines is a fast, reliable and useful tool. Since it was possible to simultaneously analyze a large number of samples with high sensibility and specificity values, the ELISA test proves to be useful for new epidemiologic studies having a high number of vectors. It is also less expensive than PCR. It is therefore recommended for epidemiological and preventive surveillance programs as a first screening test before conducting a confirmatory test using PCR.

  20. Development and validation of two measures of emotional contrast avoidance: The contrast avoidance questionnaires.

    PubMed

    Llera, Sandra J; Newman, Michelle G

    2017-06-01

    The Contrast Avoidance (CA) model (Newman & Llera, 2011) proposed that individuals with generalized anxiety disorder (GAD) fear sharp emotional shifts (or contrasts), such as the shift from a pleasant or neutral state to one of sudden distress following a negative event. Further, the model suggests that chronic worry is employed by those with GAD to sustain negative emotionality as a means to avoid sudden shifts into negativity. The model has received empirical support; however, no validated measure exists to assess CA tendencies. In this paper we developed and tested two measures of CA: one focusing on worry, and another examining broader mechanisms of CA that could be used test whether CA is applicable to other disorders. In Study 1, Part 1, we used 3 samples of participants (each N=410) to perform item reduction, exploratory factor analysis, and confirmatory factor analysis. In Study 1, Part 2, we performed tests of construct validity. In Study 2, we used a new sample (N=126) to determine test-retest reliability. All data point to the strong psychometric properties of the CA questionnaires and their relationship to GAD. Both measures distinguished between participants reporting clinical levels of GAD symptoms and nonanxious controls, demonstrating their utility as complementary measures of CA tendencies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Diagnosis of Barmah Forest Virus Infection by a Nested Real-Time SYBR Green RT-PCR Assay

    PubMed Central

    Hueston, Linda; Toi, Cheryl S.; Jeoffreys, Neisha; Sorrell, Tania; Gilbert, Gwendolyn

    2013-01-01

    Barmah Forest virus (BFV) is a mosquito borne (+) ssRNA alphavirus found only in Australia. It causes rash, myalgia and arthralgia in humans and is usually diagnosed serologically. We developed a real-time PCR assay to detect BFV in an effort to improve diagnosis early in the course of infection. The limit of detection was 16 genome equivalents with a specificity of 100%. Fifty five serum samples from BFV-infected patients were tested by the PCR. 52 of 53 antibody-positive samples were PCR negative. Two culture-positive (neutralizing antibody negative) samples were positive on first round PCR, while one sample (IgM and neutralizing antibody strongly positive, IgG negative) was positive on second round PCR, suggesting that viral RNA is detectable and transiently present in early infection. PCR can provide results faster than culture, is capable of high throughput and by sequencing the PCR product strain variants can be characterized. PMID:23935816

  2. Experimental breakdown of selected anodized aluminum samples in dilute plasmas

    NASA Technical Reports Server (NTRS)

    Grier, Norman T.; Domitz, Stanley

    1992-01-01

    Anodized aluminum samples representative of Space Station Freedom structural material were tested for electrical breakdown under space plasma conditions. In space, this potential arises across the insulating anodized coating when the spacecraft structure is driven to a negative bias relative to the external plasma potential due to plasma-surface interaction phenomena. For anodized materials used in the tests, it was found that breakdown voltage varied from 100 to 2000 volts depending on the sample. The current in the arcs depended on the sample, the capacitor, and the voltage. The level of the arc currents varied from 60 to 1000 amperes. The plasma number density varied from 3 x 10 exp 6 to 10 exp 3 ions per cc. The time between arcs increased as the number density was lowered. Corona testing of anodized samples revealed that samples with higher corona inception voltage had higher arcing inception voltages. From this it is concluded that corona testing may provide a method of screening the samples.

  3. 7 CFR 301.92-12 - Testing protocols.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    .... The following methodology is approved by APHIS. (a) Optional ELISA Prescreening. An APHIS-approved ELISA may be used to prescreen plant samples to determine the presence of Phytophthora spp. (1) Negative... ELISA prescreening, no further testing is required. The nursery may be considered free of evidence of...

  4. 7 CFR 301.92-12 - Testing protocols.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    .... The following methodology is approved by APHIS. (a) Optional ELISA Prescreening. An APHIS-approved ELISA may be used to prescreen plant samples to determine the presence of Phytophthora spp. (1) Negative... ELISA prescreening, no further testing is required. The nursery may be considered free of evidence of...

  5. 7 CFR 301.92-12 - Testing protocols.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    .... The following methodology is approved by APHIS. (a) Optional ELISA Prescreening. An APHIS-approved ELISA may be used to prescreen plant samples to determine the presence of Phytophthora spp. (1) Negative... ELISA prescreening, no further testing is required. The nursery may be considered free of evidence of...

  6. 7 CFR 301.92-12 - Testing protocols.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    .... The following methodology is approved by APHIS. (a) Optional ELISA Prescreening. An APHIS-approved ELISA may be used to prescreen plant samples to determine the presence of Phytophthora spp. (1) Negative... ELISA prescreening, no further testing is required. The nursery may be considered free of evidence of...

  7. 7 CFR 301.92-12 - Testing protocols.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    .... The following methodology is approved by APHIS. (a) Optional ELISA Prescreening. An APHIS-approved ELISA may be used to prescreen plant samples to determine the presence of Phytophthora spp. (1) Negative... ELISA prescreening, no further testing is required. The nursery may be considered free of evidence of...

  8. A weighted generalized score statistic for comparison of predictive values of diagnostic tests.

    PubMed

    Kosinski, Andrzej S

    2013-03-15

    Positive and negative predictive values are important measures of a medical diagnostic test performance. We consider testing equality of two positive or two negative predictive values within a paired design in which all patients receive two diagnostic tests. The existing statistical tests for testing equality of predictive values are either Wald tests based on the multinomial distribution or the empirical Wald and generalized score tests within the generalized estimating equations (GEE) framework. As presented in the literature, these test statistics have considerably complex formulas without clear intuitive insight. We propose their re-formulations that are mathematically equivalent but algebraically simple and intuitive. As is clearly seen with a new re-formulation we presented, the generalized score statistic does not always reduce to the commonly used score statistic in the independent samples case. To alleviate this, we introduce a weighted generalized score (WGS) test statistic that incorporates empirical covariance matrix with newly proposed weights. This statistic is simple to compute, always reduces to the score statistic in the independent samples situation, and preserves type I error better than the other statistics as demonstrated by simulations. Thus, we believe that the proposed WGS statistic is the preferred statistic for testing equality of two predictive values and for corresponding sample size computations. The new formulas of the Wald statistics may be useful for easy computation of confidence intervals for difference of predictive values. The introduced concepts have potential to lead to development of the WGS test statistic in a general GEE setting. Copyright © 2012 John Wiley & Sons, Ltd.

  9. A weighted generalized score statistic for comparison of predictive values of diagnostic tests

    PubMed Central

    Kosinski, Andrzej S.

    2013-01-01

    Positive and negative predictive values are important measures of a medical diagnostic test performance. We consider testing equality of two positive or two negative predictive values within a paired design in which all patients receive two diagnostic tests. The existing statistical tests for testing equality of predictive values are either Wald tests based on the multinomial distribution or the empirical Wald and generalized score tests within the generalized estimating equations (GEE) framework. As presented in the literature, these test statistics have considerably complex formulas without clear intuitive insight. We propose their re-formulations which are mathematically equivalent but algebraically simple and intuitive. As is clearly seen with a new re-formulation we present, the generalized score statistic does not always reduce to the commonly used score statistic in the independent samples case. To alleviate this, we introduce a weighted generalized score (WGS) test statistic which incorporates empirical covariance matrix with newly proposed weights. This statistic is simple to compute, it always reduces to the score statistic in the independent samples situation, and it preserves type I error better than the other statistics as demonstrated by simulations. Thus, we believe the proposed WGS statistic is the preferred statistic for testing equality of two predictive values and for corresponding sample size computations. The new formulas of the Wald statistics may be useful for easy computation of confidence intervals for difference of predictive values. The introduced concepts have potential to lead to development of the weighted generalized score test statistic in a general GEE setting. PMID:22912343

  10. Evaluation of EMIT and RIA high volume test procedures for THC metabolites in urine utilizing GC/MS confirmation.

    PubMed

    Abercrombie, M L; Jewell, J S

    1986-01-01

    Results of EMIT, Abuscreen RIA, and GC/MS tests for THC metabolites in a high volume random urinalysis program are compared. Samples were field tested by non-laboratory personnel with an EMIT system using a 100 ng/mL cutoff. Samples were then sent to the Army Forensic Toxicology Drug Testing Laboratory (WRAMC) at Fort Meade, Maryland, where they were tested by RIA (Abuscreen) using a statistical 100 ng/mL cutoff. Confirmations of all RIA positives were accomplished using a GC/MS procedure. EMIT and RIA results agreed for 91% of samples. Data indicated a 4% false positive rate and a 10% false negative rate for EMIT field testing. In a related study, results for samples which tested positive by RIA for THC metabolites using a statistical 100 ng/mL cutoff were compared with results by GC/MS utilizing a 20 ng/mL cutoff for the THCA metabolite. Presence of THCA metabolite was detected in 99.7% of RIA positive samples. No relationship between quantitations determined by the two tests was found.

  11. Guidelines for the use and interpretation of nucleic acid detection tests for Neisseria gonorrhoeae in Australia: a position paper on behalf of the Public Health Laboratory Network.

    PubMed

    Smith, David W; Tapsall, John W; Lum, Gary

    2005-01-01

    The Public Health Laboratory Network (PHLN) convened a workshop of Australian experts in Melbourne on 23 March 2005 to identify laboratory issues of relevance and suggest guidelines for use of nucleic acid detection tests (NADT) for diagnosis of gonorrhoea in Australia. The proceedings of that meeting were endorsed by the members of the PHLN and the Communicable Diseases Network of Australia. Given the present state of knowledge and experience of conditions currently existing in Australia, the following recommendations were made: Recommendation 1: Assays using detection of the cppB gene should not be used for either screening or supplemental assays. Recommendation 2: All in-house screening assays that are positive should also be positive on a reliable supplemental assay before a positive result is reported. Recommendation 3: All commercial screening assays that are positive should also be positive on a reliable supplemental assay before a positive result is reported. Recommendation 4: If a sample is positive in a screening assay but a suitable supplemental assay is negative, then the result should be reported as negative. Recommendation 5: Laboratories should ensure that the test combination they use would yield a positive predictive value of at least 90 per cent in a population with a prevalence of 1 per cent. Recommendation 6: For the purposes of test evaluation, as distinct from diagnostic testing, true positives be defined by meeting one or more of the following criteria: 1) culture positive using contemporary isolation and identification techniques; 2) positive result on NADTs directed to targets on three separate genes that are known to have discriminatory capacity; 3) sequencing of a gene known to separate gonococcal from non-gonococcal species. Recommendation 7: Inhibitor controls should be routinely included in all NADT. Recommendation 8: Cultures are the preferred test for samples from non-genital sites. If however it is necessary to perform a NADT, then more stringent criteria should be applied, and positive samples should meet the 'test evaluation' criteria for a 'true positive'. Recommendation 9: In order to properly assess the routine diagnostic system in Australia, the following quality assurance samples should be distributed in addition to the routine samples currently used: 1. cppB negative N. gonorrhoeae; 2. Non-gonococcal species known to cause false positive reactions: these should be dispatched both as a single species, as well as mixture with N. gonorrhoeae. In the latter circumstance, the non-gonococcal species should be present in 10-fold excess; 3. Urine samples: preferably a single patient sample, otherwise a spiked sample. 4. Validation panels should be made that include samples that are culture positive but PCR negative. True positive samples should also be made available. In addition, a process should be established for full phenotypic and genotypic characterisation of unidentified species that yield false positive results in NADT for gonococci. Recommendation 10: Strategies should be put in place to ensure that sufficient numbers of gonococcal isolates are obtained to allow reliable monitoring of antimicrobial resistance. Recommendation 11: Public health practitioners need to define the relevant populations that need to be targeted and identify any that require enhanced surveillance.

  12. [Feline leukemia virus infection: importance and current situation in Switzerland].

    PubMed

    Hofmann-Lehmann, R; Gönczi, E; Riond, B; Meli, M; Willi, B; Howard, J; Schaarschmidt-Kiener, D; Regli, W; Gilli, U; Boretti, F

    2018-02-01

    Feline leukemia virus (FeLV) leads to fatal disease in cats with progressive infection. The aim of this study was to determine the importance of FeLV infection in Switzerland and make a comparison with previous studies. Of 881 blood samples taken from cats living in Switzerland (minimum of 20 samples per Canton), 47 samples were provirus-positive (5.3%; 95% confidence interval (CI) 3.9-7.0%) and 18 samples were antigen-positive (2%; 95% CI 1.2-3.2%). Together with data previously collected in similar studies, these findings demonstrated a decrease in prevalence between 1997 and 2003 followed by a relative constant low prevalence thereafter. Young cats (=2 years) were more frequently infected than older cats, but FeLV-positive cats were up to 15 (antigen-positive) and 19 (provirus-positive) years old. Sexually intact cats were more frequently viremic than neutered cats; purebred cats were somewhat less frequently FeLV-positive than non-purebred cats. In a second study, in which 300 saliva samples were analyzed, samples from 5 cats were FeLV-RNA positive (1.7%; 95% CI, 0.5-3.8%), although one young feral cat had been falsely assumed to be FeLV-negative based on a point-of-care test. Of the 300 cats, only 50% were FeLV tested or vaccinated, although 90% of the cats were at risk of exposure to FeLV. Testing and vaccination of all cats with exposure risk may help further decrease the prevalence of FeLV infection. Moreover, characteristics of FeLV tests should be considered, such as the risk of false negative results in the early phase of infection when performing antigen testing.

  13. Recurrent symptoms after fundoplication with a negative pH study--recurrent reflux or functional heartburn?

    PubMed

    Thompson, Sarah K; Cai, Wang; Jamieson, Glyn G; Zhang, Alison Y; Myers, Jennifer C; Parr, Zoe E; Watson, David I; Persson, Jenny; Holtmann, Gerald; Devitt, Peter G

    2009-01-01

    A small cohort of patients present after antireflux surgery complaining of recurrent heartburn. Over two thirds of these patients will have a negative 24-h pH study. The aim of our study is to determine whether these patients have an associated functional disorder or abnormal cytokine activity and to examine the reproducibility of pH testing. A prospective analysis was carried out on a cohort of patients who had undergone a fundoplication and postoperative pH testing for recurrent heartburn: group A--patients with recurrent heartburn and a negative 24-h pH study and group B (control group)--patients with recurrent heartburn and a positive pH study. Questionnaires, a blood sample, and repeat pH testing were completed. Sixty-nine patients were identified. Group A's depression score (8.6 +/- 4.1) was significantly higher than group B's (5.9 +/- 4.2; P = 0.03). Cytokine levels were similar in both groups. Forty-seven of 49 (96%) patients who underwent repeat pH testing had a negative study. Symptom-reflux correlation was highly significant (P < 0.001). Some patients with recurrent heartburn and a negative pH study have associated functional or psychiatric comorbidities such as depression. Reproducibility of 24-h pH testing in these patients is excellent.

  14. Validation of the ANSR Listeria method for detection of Listeria spp. in environmental samples.

    PubMed

    Wendorf, Michael; Feldpausch, Emily; Pinkava, Lisa; Luplow, Karen; Hosking, Edan; Norton, Paul; Biswas, Preetha; Mozola, Mark; Rice, Jennifer

    2013-01-01

    ANSR Listeria is a new diagnostic assay for detection of Listeria spp. in sponge or swab samples taken from a variety of environmental surfaces. The method is an isothermal nucleic acid amplification assay based on the nicking enzyme amplification reaction technology. Following single-step sample enrichment for 16-24 h, the assay is completed in 40 min, requiring only simple instrumentation. In inclusivity testing, 48 of 51 Listeria strains tested positive, with only the three strains of L. grayi producing negative results. Further investigation showed that L. grayi is reactive in the ANSR assay, but its ability to grow under the selective enrichment conditions used in the method is variable. In exclusivity testing, 32 species of non-Listeria, Gram-positive bacteria all produced negative ANSR assay results. Performance of the ANSR method was compared to that of the U.S. Department of Agriculture-Food Safety and Inspection Service reference culture procedure for detection of Listeria spp. in sponge or swab samples taken from inoculated stainless steel, plastic, ceramic tile, sealed concrete, and rubber surfaces. Data were analyzed using Chi-square and probability of detection models. Only one surface, stainless steel, showed a significant difference in performance between the methods, with the ANSR method producing more positive results. Results of internal trials were supported by findings from independent laboratory testing. The ANSR Listeria method can be used as an accurate, rapid, and simple alternative to standard culture methods for detection of Listeria spp. in environmental samples.

  15. Western blotting method (TESAcruzi) as a supplemental test for confirming the presence of anti-Trypanosoma cruzi antibodies in finger prick blood samples from children aged 0-5 years in Brazil.

    PubMed

    Frade, Amanda Farage; Luquetti, Alejandro O; Prata, Aluísio; Ferreira, Antonio Walter

    2011-01-01

    Some Latin American countries have plans for total control and/or eradication of Chagas disease by the main vector (Triatoma infestans) and by blood transfusion. To achieve this, patients with Chagas disease must be identified. A Western blotting test, TESAcruzi, is described as a supplemental test for diagnosis of Chagas disease using samples collected from children <5 years living in different states of Brazil. Blood samples collected by finger prick on filter paper were sent to the test laboratory by a central laboratory to confirm results obtained previously. Ten percent of negative samples, all doubtful and all positive samples were received. Commercial reagents, IgG indirect immunofluorescence, enzyme immunoassay, and a recently introduced TESAcruzi test were used. From 8788 samples, 163 (1.85%) were reactive by IgG-ELISA and 312 (3.55%) by IgG IIF. From these, 77 (0.87%) were reactive in the TESAcruzi test. The results had high clinical value to identify those truly infected. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. CINtec PLUS immunocytochemistry as a tool for the cytologic diagnosis of glandular lesions of the cervix uteri.

    PubMed

    Ravarino, Alberto; Nemolato, Sonia; Macciocu, Elena; Fraschini, Matteo; Senes, Giancarlo; Faa, Gavino; Negri, Giovanni

    2012-11-01

    Cytologic findings of glandular lesions of the cervix uteri are often difficult to evaluate. We studied the usefulness of CINtec PLUS p16/Ki-67 double stain (mtm laboratories, Heidelberg, Germany) for the diagnosis of glandular lesions. The study included 47 abnormal results on liquid-based cytologic tests with a subsequent histologic diagnosis of adenocarcinoma in situ or with early invasion, and 16 samples with negative results on follow-up. All samples were stained with CINtec PLUS p16/Ki-67 double stain. Of the neoplastic samples, 7 were excluded because of insufficient residual cellularity or loss of neoplastic cells. Of the samples that were adequate, 92.5% were stained with CINtec PLUS, whereas 7.5% were judged inconclusive. All inconclusive cases were at least 3 years old. Of the 16 negative samples, 15 (93.8%) stained negative and only 1 (6.2%) showed several positive clusters of cells. Our study shows that CINtec PLUS is a robust and useful tool for the diagnosis of glandular lesions of the cervix uteri.

  17. The diagnostic performance evaluation of the SD BIOLINE HIV/syphilis Duo rapid test in southern Ethiopia: a cross-sectional study

    PubMed Central

    Shimelis, Techalew; Tadesse, Endale

    2015-01-01

    Objective To determine the diagnostic performance of the SD BIOLINE HIV/syphilis Duo rapid test. Design A hospital-based cross-sectional study. Setting This evaluation was conducted at one of the largest hospitals in southern Ethiopia. Participants Serum samples obtained from clients attending the antiretroviral therapy and voluntary counselling and testing centres were used. Sera were originally collected for the purpose of investigating syphilis epidemiology. The performance of the test to detect HIV was evaluated using 400 sera (200 HIV positives and 200 HIV negatives). Also, its performance to detect syphilis was evaluated using 85 syphilis positive and 100 syphilis negative serum samples. Individuals <15 years of age or syphilis treated or those with ≤50 cells/µL CD4 cell count were originally excluded. Outcome measures HIV screening was carried out according to the national rapid diagnostic testing (RDT) algorithm: Shenghai Kehua Bioengineering (KHB) test kit as a screening test, followed by the HIV1/2 STAT-PAK assay if positive. Where the result of the STAT-PAK is discordant with KHB, Unigold HIV is used as a tiebreaker to determine the result. We also used ELISA to resolve discordant HIV results. Syphilis serostatus was determined using the Treponema pallidum haemagglutination assay (TPHA). Results The respective sensitivity, specificity, positive predictive value and negative predictive value of the SD BIOLINE HIV/syphilis Duo test were 100, 99.5, 99.5 and 100% for HIV and 97.6, 96, 95.4 and 98% for syphilis testing, respectively. In reference to TPHA, the test kit reported 4 false positives and 2 false negative results for syphilis. The κ values were 0.99 for HIV testing and 0.94 for syphilis testing. Conclusions The excellent performance of the SD BIOLINE HIV/syphilis Duo test to detect HIV as well as syphilis facilitates the integration of syphilis testing and treatment to the already established HIV prevention programme, ultimately contributing to the dual HIV and syphilis elimination goal. PMID:25908677

  18. The diagnostic performance evaluation of the SD BIOLINE HIV/syphilis Duo rapid test in southern Ethiopia: a cross-sectional study.

    PubMed

    Shimelis, Techalew; Tadesse, Endale

    2015-04-23

    To determine the diagnostic performance of the SD BIOLINE HIV/syphilis Duo rapid test. A hospital-based cross-sectional study. This evaluation was conducted at one of the largest hospitals in southern Ethiopia. Serum samples obtained from clients attending the antiretroviral therapy and voluntary counselling and testing centres were used. Sera were originally collected for the purpose of investigating syphilis epidemiology. The performance of the test to detect HIV was evaluated using 400 sera (200 HIV positives and 200 HIV negatives). Also, its performance to detect syphilis was evaluated using 85 syphilis positive and 100 syphilis negative serum samples. Individuals <15 years of age or syphilis treated or those with ≤50 cells/µL CD4 cell count were originally excluded. HIV screening was carried out according to the national rapid diagnostic testing (RDT) algorithm: Shenghai Kehua Bioengineering (KHB) test kit as a screening test, followed by the HIV1/2 STAT-PAK assay if positive. Where the result of the STAT-PAK is discordant with KHB, Unigold HIV is used as a tiebreaker to determine the result. We also used ELISA to resolve discordant HIV results. Syphilis serostatus was determined using the Treponema pallidum haemagglutination assay (TPHA). The respective sensitivity, specificity, positive predictive value and negative predictive value of the SD BIOLINE HIV/syphilis Duo test were 100, 99.5, 99.5 and 100% for HIV and 97.6, 96, 95.4 and 98% for syphilis testing, respectively. In reference to TPHA, the test kit reported 4 false positives and 2 false negative results for syphilis. The κ values were 0.99 for HIV testing and 0.94 for syphilis testing. The excellent performance of the SD BIOLINE HIV/syphilis Duo test to detect HIV as well as syphilis facilitates the integration of syphilis testing and treatment to the already established HIV prevention programme, ultimately contributing to the dual HIV and syphilis elimination goal. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Comparative evaluation of recombinant LigB protein and heat-killed antigen-based latex agglutination test with microscopic agglutination test for diagnosis of bovine leptospirosis.

    PubMed

    Nagalingam, Mohandoss; Thirumalesh, Sushma Rahim Assadi; Kalleshamurthy, Triveni; Niharika, Nakkala; Balamurugan, Vinayagamurthy; Shome, Rajeswari; Sengupta, Pinaki Prasad; Shome, Bibek Ranjan; Prabhudas, Krishnamsetty; Rahman, Habibur

    2015-10-01

    This study aimed to develop latex agglutination test (LAT) using recombinant leptospiral immunoglobulin-like protein (LigB) (rLigB) antigen and compare its diagnostic efficacy with LAT using conventional heat-killed leptospiral antigen and microscopic agglutination test (MAT) in diagnosing bovine leptospirosis. The PCR-amplified 1053-bp ligB gene sequences from Leptospira borgpetersenii Hardjo serovar were cloned in pET 32 (a) vector at EcoRI and NotI sites and expressed in BL21 E. coli cells as fusion protein with thioredoxin (-57 kDa) and characterized by SDS-PAGE and immunoblot. Out of 390 serum samples [cattle (n = 214), buffaloes (n = 176)] subjected to MAT, 115 samples showed reciprocal titre≥100 up to 1600 against one or more serovars. For recombinant LigB protein/antigen-based LAT, agglutination was observed in the positive sample, while no agglutination was observed in the negative sample. Similarly, heat-killed leptospiral antigen was prepared from and used in LAT for comparison with MAT. A two-sided contingency table was used for analysis of LAT using both the antigens separately against MAT for 390 serum samples. The sensitivity, specificity and positive and negative predictive values of recombinant LigB LAT were found to be 75.65, 91.27, 78.38 and 89.96 %, respectively, and that of heat-killed antigen-based LAT were 72.17, 89.82, 74.77 and 88.53 %, respectively, in comparison with MAT. This developed test will be an alternative/complementary to the existing battery of diagnostic assays/tests for specific detection of pathogenic Leptospira infection in bovine population.

  20. Comparison of the AdvanSure human papillomavirus screening real-time PCR, the Abbott RealTime High Risk human papillomavirus test, and the Hybrid Capture human papillomavirus DNA test for the detection of human papillomavirus.

    PubMed

    Hwang, Yusun; Lee, Miae

    2012-05-01

    We evaluated the performance of various commercial assays for the molecular detection of human papillomavirus (HPV); the recently developed AdvanSure HPV Screening real-time PCR assay (AdvanSure PCR) and the Abbott RealTime High Risk HPV PCR assay (Abbott PCR) were compared with the Hybrid Capture 2 HPV DNA Test (HC2). All 3 tests were performed on 177 samples, and any sample that showed a discrepancy in any of the 3 tests was genotyped using INNO-LiPA HPV genotyping and/or sequencing. On the basis of these results, we obtained a consensus HPV result, and the performance of each test was evaluated. We also evaluated high-risk HPV 16/18 detection by using the 2 real-time PCR assays. Among the 177 samples, 65 were negative and 75 were positive in all 3 assays; however, the results of the 3 assays with 37 samples were discrepant. Compared with the consensus HPV result, the sensitivities and specificities of HC2, AdvanSure PCR, and Abbott PCR were 97.6%, 91.7%, and 86.9% and 83.9%, 98.8%, and 100.0%, respectively. For HPV type 16/18 detection, the concordance rate between the AdvanSure PCR and Abbott PCR assays was 98.3%; however, 3 samples were discrepant (positive in AdvanSure PCR and negative in Abbott PCR) and were confirmed as HPV type 16 by INNO-LiPA genotyping and/or sequencing. For HPV detection, the AdvanSure HPV Screening real-time PCR assay and the Abbott PCR assay are less sensitive but more specific than the HC2 assay, but can simultaneously differentiate type 16/18 HPV from other types.

  1. Validation of the Explorer® 2.0 test coupled to e-Reader® for the screening of antimicrobials in muscle from different animal species.

    PubMed

    Mata, Luis; Sanz, David; Razquin, Pedro

    2014-01-01

    The Explorer(®) 2.0 tube test is a microbial inhibition test for the screening of antimicrobial residues in food samples. The new e-Reader(®) device coupled to Explorer(®) 2.0 operates by incubation at a selected temperature, determination of the endpoint of the assay and interpretation to generate results. This system was validated for muscle samples according to the European Commission Decision 2002/657/EC. Sensitivity towards 25 substances from several groups of antimicrobials was investigated in a first step. Detection capabilities for six substances representing the six major antimicrobial groups were also determined in bovine muscle. The detection capabilities for amoxicillin (10 µg l(-1)), cefalexin (200 µg l(-1)), doxycyclin (100 µg l(-1)), sulfamethazine (100 µg l(-1)), tylosin (100 µg l(-1)) and neomycin (200 µg l(-1)) were in all cases at or below the maximum residue limit (MRL). Specificity and applicability of the test were demonstrated with muscle samples from four animal species (bovine, porcine, ovine and poultry) and results were found to be satisfactory. Ruggedness was evaluated on negative and spiked samples with sulfamethazine as a representative antimicrobial. Neither false-positives nor false-negatives were detected when varying the sample volume, the time of pre-incubation, the temperature of incubation and the batch of the test. These results prove that Explorer(®) 2.0 coupled to e-Reader(®) is a valuable tool for the screening of a broad range of antimicrobials in muscle. This new methodology simplifies the analysis and increases the accuracy of interpretation of the test results since the endpoint of the assay is automatically determined and results are interpreted objectively.

  2. Adverse Life Events and Emotional and Behavioral Problems in Adolescence: The Role of Non-Verbal Cognitive Ability and Negative Cognitive Errors

    ERIC Educational Resources Information Center

    Flouri, Eirini; Panourgia, Constantina

    2011-01-01

    The aim of this study was to test whether negative cognitive errors (overgeneralizing, catastrophizing, selective abstraction, and personalizing) mediate the moderator effect of non-verbal cognitive ability on the association between adverse life events (life stress) and emotional and behavioral problems in adolescence. The sample consisted of 430…

  3. Suicide and War: The Mediating Effects of Negative Mood, Posttraumatic Stress Disorder Symptoms, and Social Support among Army National Guard Soldiers

    ERIC Educational Resources Information Center

    Griffith, James

    2012-01-01

    The mediating effects of posttraumatic stress disorder (PTSD) symptoms, negative mood, and social support on the relationship of war experiences to suicidality were examined. The research literature suggested a sequence among study scales representing these constructs, which was then tested on survey data obtained from a sample of National Guard…

  4. The "hook effect" causing a negative pregnancy test in a patient with an advanced molar pregnancy.

    PubMed

    Winder, Abigail D; Mora, Adria Suarez; Berry, Emily; Lurain, John R

    2017-08-01

    •At high hCG levels in molar pregnancies, a "hook effect" can cause an artificially negative value.•Delay in diagnosis of a molar pregnancy due to the "hook effect" can lead to severe complications.•Suspicion of a molar pregnancy should be communicated so a diluted sample is used to quantify hCG.

  5. Linkages between Negative Work-to-Family Spillover and Mothers' and Fathers' Knowledge of Their Young Adolescents Daily Lives

    ERIC Educational Resources Information Center

    Bumpus, Matthew F.; Crouter, Ann C.; McHale, Susan M.

    2006-01-01

    This study examines the relationships between mothers' and fathers' perceptions of negative work-to-family spillover and their knowledge of their preadolescent children's (mean age = 11.8 years) daily lives in a sample of dual-earner families. Three constructs are tested as potential mediators of the association between spillover and parental…

  6. Body Dissatisfaction and Eating Disturbances in Early Adolescence: A Structural Modeling Investigation Examining Negative Affect and Peer Factors

    ERIC Educational Resources Information Center

    Hutchinson, Delyse M.; Rapee, Ronald M.; Taylor, Alan

    2010-01-01

    This study tested five proposed models of the relationship of negative affect and peer factors in early adolescent body dissatisfaction, dieting, and bulimic behaviors. A large community sample of girls in early adolescence was assessed via questionnaire (X[overbar] age = 12.3 years). Structural equation modeling (SEM) indicated that negative…

  7. Quantitative detection of PfHRP2 in saliva of malaria patients in the Philippines

    PubMed Central

    2012-01-01

    Background Malaria is a global health priority with a heavy burden of fatality and morbidity. Improvements in field diagnostics are needed to support the agenda for malaria elimination. Saliva has shown significant potential for use in non-invasive diagnostics, but the development of off-the-shelf saliva diagnostic kits requires best practices for sample preparation and quantitative insight on the availability of biomarkers and the dynamics of immunoassay in saliva. This pilot study measured the levels of the PfHRP2 in patient saliva to inform the development of salivary diagnostic tests for malaria. Methods Matched samples of blood and saliva were collected between January and May, 2011 from eight patients at Palawan Baptist Hospital in Roxas, Palawan, Philippines. Parasite density was determined from thick-film blood smears. Concentrations of PfHRP2 in saliva of malaria-positive patients were measured using a custom chemiluminescent ELISA in microtitre plates. Sixteen negative-control patients were enrolled at UCLA. A substantive difference between this protocol and previous related studies was that saliva samples were stabilized with protease inhibitors. Results Of the eight patients with microscopically confirmed P. falciparum malaria, seven tested positive for PfHRP2 in the blood using rapid diagnostic test kits, and all tested positive for PfHRP2 in saliva. All negative-control samples tested negative for salivary PfHRP2. On a binary-decision basis, the ELISA agreed with microscopy with 100 % sensitivity and 100 % specificity. Salivary levels of PfHRP2 ranged from 17 to 1,167 pg/mL in the malaria-positive group. Conclusion Saliva is a promising diagnostic fluid for malaria when protein degradation and matrix effects are mitigated. Systematic quantitation of other malaria biomarkers in saliva would identify those with the best clinical relevance and suitability for off-the-shelf diagnostic kits. PMID:22631858

  8. Negative body talk measures for Asian, Latina(o), and White women and men: Measurement equivalence and associations with ethnic-racial identity.

    PubMed

    Sladek, Michael R; Salk, Rachel H; Engeln, Renee

    2018-06-01

    Negative body talk measures have been developed with predominantly White, female samples. We tested measurement invariance (equivalence) of two available negative body talk scales for Asian, Latina(o), and White college women and men in the U.S. In Study 1 (n = 1501 women; n = 1436 men), multiple group confirmatory factor analyses indicated scalar (strong) invariance across groups for the Negative Body Talk (Engeln-Maddox, Salk, & Miller, 2012) and Male Body Talk (Sladek, Engeln, & Miller, 2014) scales, suggesting these measures can be used to test mean group differences. Ethnic group comparisons adjusting for body mass index (BMI) showed similarities overall; few differences that emerged had small effect sizes. In Study 2 (n = 227 women; n = 141 men), greater ethnic-racial identity resolution was associated with less frequent negative body talk for Latina and Asian women but more frequent muscularity-focused negative body talk for Asian men, adjusting for BMI. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Feasibility of a handheld near infrared device for the qualitative analysis of bloodstains.

    PubMed

    Morillas, Alvaro Varela; Gooch, James; Frascione, Nunzianda

    2018-07-01

    One of the most common tasks in criminal investigation is to determine from which tissue source a biological fluid stain originates. As a result, there are many tests that are frequently used to determine if a stain is blood, semen or saliva by exploiting the properties of certain molecules present within the fluids themselves. These include chemical reagents such as the Kastle-Meyer or Acid Phosphatase tests, as well as other techniques like the use of alternative light sources. However, most of the tests currently available have some major drawbacks. In this study, a handheld near-infrared spectrometer is investigated for the specific identification of deposited bloodstains. First, a calibration was carried out by scanning over 500 positive (blood present) and negative (blood absent) samples to train several predictive models based on machine learning principles. These models were then tested on over 100 new positive and negative samples to evaluate their performance. All models tested were able to correctly classify deposited stains as blood in at least 81% of tested samples, with some models allowing for even higher classification accuracy at over 94%. This suggests that handheld near infrared devices could offer great opportunity for the rapid, low cost and non-destructive screening of body fluids at scenes of crime. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Hepatitis C Testing

    PubMed Central

    Rochlani, Maya; Lewis, Jessica H.; Ramsey, Glenn E.; Bontempo, Franklin A.; Shah, Gunjan; Bowman, Rebecca A.; van Thiel, David H.; Starzl, Thomas E.

    2010-01-01

    Plasma samples from 1,182 patients undergoing primary liver transplantation were tested for anti-hepatitis C (HCV) virus by two methods: Ortho HCV ELISA Test System (EIA) and Chiron RIBA HCV Test System (RIBA II). The EIA results, 0 or +, were recorded first, followed by RIBA results, N = negative, P = positive, or I = indeterminate. Concordant results—0N, + P, + I—were found in 1,076 (91%), and discordant results were found in 106 (9%). The EIA optical density did not relate to concordant or discordant results. Band patterns were described by stating the band position (1, 2, 3, or 4) and insetting a dash (−) if no band was visualized. Most + P samples fell into two patterns: 47% showed all four bands, pattern 1234, and 15% showed the two-band pattern, 34. When the EIA was negative, 0P, the opposite was seen: 8% showed the 1234 pattern and 81% showed the 34 pattern. There were 226 samples that formed bands (+ P, 149; 0P, 31; + I, 15; 0I, 31). The frequency of bands was as follows: 4, 32%; 3, 31%; 2, 19%; and 1, 18%. Band 2 and the EIA test detected antibodies to the same c100-3 fragment and showed 74% concordance. No explanation is apparent for the lower concordance rate here than that between the EIA test and bands 3 = 96% or 4 = 88%. The EIA and RIBA II tests, together with positive liver function tests and abnormal tissue pathologic findings, provide a basis for the diagnosis of HCV. PMID:1377442

  11. Oral antibiotic adverse reactions after penicillin skin testing: multi-year follow-up.

    PubMed

    Macy, E; Burchette, R J

    2002-12-01

    Long-term follow-up data on adverse drug reactions after oral antibiotic use in penicillin allergy history positive individuals with penicillin skin test done in advance of need are rare. Oral antibiotic associated adverse drug reactions in 83 penicillin skin test positive individuals were compared to a sex, age, and length of follow-up matched sample of 166 penicillin skin test negative individuals, all of whom had at least one post penicillin skin test oral antibiotic. The mean post penicillin skin test follow-up interval was 34.5 +/- 16.6 months. There were 1655 total oral antibiotic exposures. In penicillin skin test positive individuals, the adverse drug reaction rate was not significantly different with cephalosporin or non-beta-lactam use (P = 0.12). In penicillin skin test negative individuals the adverse drug reaction rate was significantly lower with cephalosporin vs. non-beta-lactam use (P = 0.005). Penicillin was safely used in penicillin skin test negative individuals. Overall cephalosporins caused fewer adverse drug reactions independent of penicillin skin test status (P = 0.005). Penicillin skin testing was only able to predict penicillin associated adverse drug reactions in penicillin skin test positive individuals. Excluding accidental penicillin exposure in penicillin skin test positive individuals, non-beta-lactams were associated with adverse drug reactions more often than penicillins or cephalosporins, independent of the penicillin skin test result. Cephalosporins were used as or more safely than non-beta-lactams in both penicillin skin test positive and negative individuals.

  12. The Relationship Between Trust-in-God, Positive and Negative Affect, and Hope.

    PubMed

    Fadardi, Javad S; Azadi, Zeinab

    2017-06-01

    We aimed to test the relationships between Trust-in-God, positive and negative affect, and feelings of hope. A sample of university students (N = 282, 50 % female) completed the Positive and Negative Affect Schedule, the Adult Dispositional Hope Scale, and a Persian measure of Trust-in-God for Muslims. The results of a series of hierarchical regression analyses indicated that Trust-in-God was positively associated with participants' scores for hope and positive affect but was negatively associated with their scores for negative affect. The results support the relationship between Trust-in-God and indices of mental health.

  13. An empirical probability model of detecting species at low densities.

    PubMed

    Delaney, David G; Leung, Brian

    2010-06-01

    False negatives, not detecting things that are actually present, are an important but understudied problem. False negatives are the result of our inability to perfectly detect species, especially those at low density such as endangered species or newly arriving introduced species. They reduce our ability to interpret presence-absence survey data and make sound management decisions (e.g., rapid response). To reduce the probability of false negatives, we need to compare the efficacy and sensitivity of different sampling approaches and quantify an unbiased estimate of the probability of detection. We conducted field experiments in the intertidal zone of New England and New York to test the sensitivity of two sampling approaches (quadrat vs. total area search, TAS), given different target characteristics (mobile vs. sessile). Using logistic regression we built detection curves for each sampling approach that related the sampling intensity and the density of targets to the probability of detection. The TAS approach reduced the probability of false negatives and detected targets faster than the quadrat approach. Mobility of targets increased the time to detection but did not affect detection success. Finally, we interpreted two years of presence-absence data on the distribution of the Asian shore crab (Hemigrapsus sanguineus) in New England and New York, using our probability model for false negatives. The type of experimental approach in this paper can help to reduce false negatives and increase our ability to detect species at low densities by refining sampling approaches, which can guide conservation strategies and management decisions in various areas of ecology such as conservation biology and invasion ecology.

  14. Impaired Decisional Impulsivity in Pathological Videogamers

    PubMed Central

    Irvine, Michael A.; Worbe, Yulia; Bolton, Sorcha; Harrison, Neil A.; Bullmore, Edward T.; Voon, Valerie

    2013-01-01

    Background Pathological gaming is an emerging and poorly understood problem. Impulsivity is commonly impaired in disorders of behavioural and substance addiction, hence we sought to systematically investigate the different subtypes of decisional and motor impulsivity in a well-defined pathological gaming cohort. Methods Fifty-two pathological gaming subjects and age-, gender- and IQ-matched healthy volunteers were tested on decisional impulsivity (Information Sampling Task testing reflection impulsivity and delay discounting questionnaire testing impulsive choice), and motor impulsivity (Stop Signal Task testing motor response inhibition, and the premature responding task). We used stringent diagnostic criteria highlighting functional impairment. Results In the Information Sampling Task, pathological gaming participants sampled less evidence prior to making a decision and scored fewer points compared with healthy volunteers. Gaming severity was also negatively correlated with evidence gathered and positively correlated with sampling error and points acquired. In the delay discounting task, pathological gamers made more impulsive choices, preferring smaller immediate over larger delayed rewards. Pathological gamers made more premature responses related to comorbid nicotine use. Greater number of hours played also correlated with a Motivational Index. Greater frequency of role playing games was associated with impaired motor response inhibition and strategy games with faster Go reaction time. Conclusions We show that pathological gaming is associated with impaired decisional impulsivity with negative consequences in task performance. Decisional impulsivity may be a potential target in therapeutic management. PMID:24146789

  15. Paper-based assay for red blood cell antigen typing by the indirect antiglobulin test.

    PubMed

    Yeow, Natasha; McLiesh, Heather; Guan, Liyun; Shen, Wei; Garnier, Gil

    2016-07-01

    A rapid and simple paper-based elution assay for red blood cell antigen typing by the indirect antiglobulin test (IAT) was established. This allows to type blood using IgG antibodies for the important blood groups in which IgM antibodies do not exist. Red blood cells incubated with IgG anti-D were washed with saline and spotted onto the paper assay pre-treated with anti-IgG. The blood spot was eluted with an elution buffer solution in a chromatography tank. Positive samples were identified by the agglutinated and fixed red blood cells on the original spotting area, while red blood cells from negative samples completely eluted away from the spot of origin. Optimum concentrations for both anti-IgG and anti-D were identified to eliminate the washing step after the incubation phase. Based on the no-washing procedure, the critical variables were investigated to establish the optimal conditions for the paper-based assay. Two hundred ten donor blood samples were tested in optimal conditions for the paper test with anti-D and anti-Kell. Positive and negative samples were clearly distinguished. This assay opens up new applications of the IAT on paper including antibody detection and blood donor-recipient crossmatching and extends its uses into non-blood typing applications with IgG antibody-based diagnostics. Graphical abstract A rapid and simple paper-based assay for red blood cell antigen typing by the indirect antiglobulin test.

  16. Development and testing of monoclonal antibody-based rapid immunodiagnostic test kits for direct detection of Vibrio cholerae O139 synonym Bengal.

    PubMed

    Hasan, J A; Huq, A; Nair, G B; Garg, S; Mukhopadhyay, A K; Loomis, L; Bernstein, D; Colwell, R R

    1995-11-01

    We report on the development and testing of two monoclonal antibody-based rapid immunodiagnostic test kits, BengalScreen, a coagglutination test, and Bengal DFA, a direct fluorescent-antibody test, for direct detection of Vibrio cholerae O139 synonym Bengal in clinical and environmental specimens. The BengalScreen test requires less than 5 min to complete and can be used in the field. Bengal DFA, being more sensitive than BengalScreen, requires only one reagent and less than 20 min for detection and enumeration of V. cholerae O139 synonym Bengal. In tests for specificity, all 40 strains of V. cholerae O139 reacted with both test kits, whereas 157 strains of heterologous species examined did not, yielding 100% specificity in this study. A field trial was conducted in with both BengalScreen and Bengal DFA, and the results were compared with those obtained by conventional culture methods. BengalScreen demonstrated a sensitivity of 95%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 94%. Results obtained by Bengal DFA, on the other hand, were 100% sensitive and 100% specific and yielded 100% positive and negative predictive values compared with culture methods. In a second evaluation, 93 stool specimens from Mexico that were negative for V. cholerae O139 by culture were also tested with both the BengalScreen and Bengal DFA kits. None of the 93 specimens were positive for V. cholerae O139 by both tests. A concentration method was optimized for screening of environmental water samples for V. cholerae O139 synonym Bengal with rapid test kits. BengalScreen results were unequivocally positive when water samples contained at least 2.0 x 10(3) CFU/ml, whereas Bengal DFA demonstrated an unequivocally positive reaction when the water sample contained at least 1.5 x 10(2) CFU/ml. When Bengal DFA was compared with conventional culture methods for enumeration of V. cholerae O139 synonym Bengal organisms, no difference was observed.

  17. Bead-based microfluidic immunoassay for diagnosis of Johne's disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wadhwa, Ashutosh; Foote, Robert; Shaw, Robert W

    2012-01-01

    Microfluidics technology offers a platform for development of point-of-care diagnostic devices for various infectious diseases. In this study, we examined whether serodiagnosis of Johne s disease (JD) can be conducted in a bead-based microfluidic assay system. Magnetic micro-beads were coated with antigens of the causative agent of JD, Mycobacterium avium subsp. paratuberculosis. The antigen-coated beads were incubated with serum samples of JD-positive or negative serum samples and then with a fluorescently-labeled secondary antibody (SAB). To confirm binding of serum antibodies to the antigen, the beads were subjected to flow cytometric analysis. Different conditions (dilutions of serum and SAB, types ofmore » SAB, and types of magnetic beads) were optimized for a great degree of differentiation between the JD-negative and JD-positive samples. Using the optimized conditions, we tested a well-classified set of 155 serum samples from JD negative and JD-positive cattle by using the bead-based flow cytometric assay. Of 105 JD-positive samples, 63 samples (60%) showed higher antibody binding levels than a cut-off value determined by using antibody binding levels of JD-negative samples. In contrast, only 43-49 JD-positive samples showed higher antibody binding levels than the cut-off value when the samples were tested by commercially-available immunoassays. Microfluidic assays were performed by magnetically immobilizing a number of beads within a microchannel of a glass microchip and detecting antibody on the collected beads by laser-induced fluorescence. Antigen-coated magnetic beads treated with bovine serum sample and fluorescently-labeled SAB were loaded into a microchannel to measure the fluorescence (reflecting level of antibody binding) on the beads in the microfluidic system. When the results of five bovine serum samples obtained with the system were compared to those obtained with the flow cytometer, a high level of correlation (linear regression, r2 = 0.994) was observed. In a further experiment, we magnetically immobilized antigen-coated beads in a microchannel, reacted the beads with serum and SAB in the channel, and detected antibody binding to the beads in the microfluidic system. A strong antibody binding in JD-positive serum was detected, whereas there was only negligible binding in negative control experiments. Our data suggest that the bead-based microfluidic system may form a basis for development of an on-site serodiagnosis of JD. Key Words: Mycobacterium avium ssp. paratuberculosis, Johne s disease, microfluidics, lab-on-a-chip.« less

  18. Evaluation of a rapid diagnostic test (CareStart™ Malaria HRP-2/pLDH (Pf/pan) Combo Test) for the diagnosis of malaria in a reference setting

    PubMed Central

    2010-01-01

    Background Malaria Rapid Diagnostic Tests (RDTs) are widely used for diagnosing malaria. The present retrospective study evaluated the CareStart™ Malaria HRP-2/pLDH (Pf/pan) Combo Test targeting the Plasmodium falciparum specific antigen histidine-rich protein (HRP-2) and the pan-Plasmodium antigen lactate dehydrogenase (pLDH) in a reference setting. Methods The CareStart™ Malaria HRP-2/pLDH (Pf/pan) Combo Test was evaluated on a collection of samples obtained in returned international travellers using microscopy corrected by PCR as the reference method. Included were P. falciparum (n = 320), Plasmodium vivax (n = 76), Plasmodium ovale (n = 76), Plasmodium malariae (n = 23) and Plasmodium negative samples (n = 95). Results Overall sensitivity for the detection of P. falciparum was 88.8%, increasing to 94.3% and 99.3% at parasite densities above 100 and 1,000/μl respectively. For P. vivax, P. ovale and P. malariae, overall sensitivities were 77.6%, 18.4% and 30.4% respectively. For P. vivax sensitivity reached 90.2% for parasite densities above 500/μl. Incorrect species identification occurred in 11/495 samples (2.2%), including 8/320 (2.5%) P. falciparum samples which generated only the pan-pLDH line. For P. falciparum samples, 205/284 (72.2%) HRP-2 test lines had strong or medium line intensities, while for all species the pan-pLDH lines were less intense, especially in the case of P. ovale. Agreement between observers was excellent (kappa values > 0.81 for positive and negative readings) and test results were reproducible. The test was easy to perform with good clearing of the background. Conclusion The CareStart™ Malaria HRP-2/pLDH (Pf/pan) Combo Test performed well for the detection of P. falciparum and P. vivax, but sensitivities for P. ovale and P. malariae were poor. PMID:20565816

  19. Evaluation of a rapid diagnostic test (CareStart Malaria HRP-2/pLDH (Pf/pan) Combo Test) for the diagnosis of malaria in a reference setting.

    PubMed

    Maltha, Jessica; Gillet, Philippe; Bottieau, Emmanuel; Cnops, Lieselotte; van Esbroeck, Marjan; Jacobs, Jan

    2010-06-18

    Malaria Rapid Diagnostic Tests (RDTs) are widely used for diagnosing malaria. The present retrospective study evaluated the CareStart Malaria HRP-2/pLDH (Pf/pan) Combo Test targeting the Plasmodium falciparum specific antigen histidine-rich protein (HRP-2) and the pan-Plasmodium antigen lactate dehydrogenase (pLDH) in a reference setting. The CareStart Malaria HRP-2/pLDH (Pf/pan) Combo Test was evaluated on a collection of samples obtained in returned international travellers using microscopy corrected by PCR as the reference method. Included were P. falciparum (n = 320), Plasmodium vivax (n = 76), Plasmodium ovale (n = 76), Plasmodium malariae (n = 23) and Plasmodium negative samples (n = 95). Overall sensitivity for the detection of P. falciparum was 88.8%, increasing to 94.3% and 99.3% at parasite densities above 100 and 1,000/microl respectively. For P. vivax, P. ovale and P. malariae, overall sensitivities were 77.6%, 18.4% and 30.4% respectively. For P. vivax sensitivity reached 90.2% for parasite densities above 500/microl. Incorrect species identification occurred in 11/495 samples (2.2%), including 8/320 (2.5%) P. falciparum samples which generated only the pan-pLDH line. For P. falciparum samples, 205/284 (72.2%) HRP-2 test lines had strong or medium line intensities, while for all species the pan-pLDH lines were less intense, especially in the case of P. ovale. Agreement between observers was excellent (kappa values > 0.81 for positive and negative readings) and test results were reproducible. The test was easy to perform with good clearing of the background. The CareStart Malaria HRP-2/pLDH (Pf/pan) Combo Test performed well for the detection of P. falciparum and P. vivax, but sensitivities for P. ovale and P. malariae were poor.

  20. Components of Implicit Stigma against Mental Illness among Chinese Students

    PubMed Central

    Wang, Xiaogang; Huang, Xiting; Jackson, Todd; Chen, Ruijun

    2012-01-01

    Although some research has examined negative automatic aspects of attitudes toward mental illness via relatively indirect measures among Western samples, it is unclear whether negative attitudes can be automatically activated in individuals from non-Western countries. This study attempted to validate results from Western samples with Chinese college students. We first examined the three-component model of implicit stigma (negative cognition, negative affect, and discriminatory tendencies) toward mental illness with the Single Category Implicit Association Test (SC-IAT). We also explored the relationship between explicit and implicit stigma among 56 Chinese university college students. In the three separate SC-IATs and the combined SC-IAT, automatic associations between mental illness and negative descriptors were stronger relative to those with positive descriptors and the implicit effect of cognitive and affective SC-IATs were significant. Explicit and implicit measures of stigma toward mental illness were unrelated. In our sample, women's overall attitudes toward mental illness were more negative than men's were, but no gender differences were found for explicit measures. These findings suggested that implicit stigma toward mental illness exists in Chinese students, and provide some support for the three-component model of implicit stigma toward mental illness. Future studies that focus on automatic components of stigmatization and stigma-reduction in China are warranted. PMID:23029366

  1. Performance comparison of new generation HCV core antigen test versus HCV RNA test in management of hepatitis C virus infection.

    PubMed

    Çetiner, Salih; Çetin Duran, Alev; Kibar, Filiz; Yaman, Akgün

    2017-06-01

    The study has evaluated the performance of HCV core antigen (Cag) test by comparing HCV RNA PCR assay which is considered the gold standard for management of HCV infection. Totally, 132 samples sent for HCV RNA (real-time PCR) test were included in the study. Anti-HCV antibody test and HCV Cag test were performed by chemiluminescent enzyme immunoassay (CMEI). Anti-HCV test was positive in all samples. HCV RNA was detected in 112/132 (84.8%) samples, and HCV Cag in 105/132 (79.5%). The most common HCV genotype was genotype 1 (86%). Considering the HCV RNA test as gold standard; the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of Cag test were found to be 93.75%, 100%, 100%, 74.07% and 94.69%, respectively, and paired test results were detected as highly concordant. A high level of correlation was seen between HCV RNA and Cag tests, however, the concordance between the two tests appeared to be disrupted at viral loads lower than 10 3 IU/mL. On the contrary, the correlation reached significance for the values higher than 10 3 IU/mL. Viral loads were in the 17-2500IU/mL range for the negative results for Cag test. Pearson's correlation coefficient revealed a considerably high correlation. The concordance between HCV RNA and Cag tests was disrupted under a viral load lower than 10 3 IU/mL. Therefore, it would be appropriate to consider cost effectiveness, advantages and limitations of the HCV RNA and Cag tests during the decision on which method to use for patient management. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Comparison of plasma and tissue samples in epidermal growth factor receptor mutation by ARMS in advanced non-small cell lung cancer.

    PubMed

    Ma, MeiLi; Shi, ChunLei; Qian, JiaLin; Teng, JiaJun; Zhong, Hua; Han, BaoHui

    2016-10-10

    The aim of this study was to assess the effectiveness and accuracy of blood-based circulating-free tumor DNA on testing epidermal growth factor receptor (EGFR) gene mutations. In total, 219 non-small cell lung cancer patients in stages III-IV were enrolled into this study. All patients had tissue samples and matched plasma DNA samples. EGFR gene mutations were detected by the Amplification Refractory Mutation System (ARMS). We compared the mutations in tumor tissue samples with matched plasma samples and determined the correlation between EGFR mutation status and clinical pathologic characteristics. The overall concordance rate of EGFR mutation status between the 219 matched plasma and tissue samples was 82% (179/219). The sensitivity and specificity for the ARMS EGFR mutation test in the plasma compared with tumor tissue were 60% (54/90) and 97% (125/129), respectively. The positive predictive value was 93% (54/58) and the negative predictive value was 78% (125/161). The median overall survival was longer for those with EGFR mutations than for those without EGFR mutations both in tissue samples (23.98 vs. 12.16months; P<0.001) and in plasma (19.96 vs. 13.63months; P=0.009). For the 68 patients treated with EGFR- tyrosine kinase inhibitors (TKIs), the median progression-free survival (PFS) was significantly prolonged in the EGFR mutant group compared to the non-mutation group in tumor tissue samples (12.26months vs. 2.40months, P<0.001). In plasma samples, the PFS of the mutant group was longer than that of the non-mutant group. However, there was no significant difference between the two groups (10.88months vs. 9.89months, P=0.411). The detection of EGFR mutations in plasma using ARMS is relatively sensitive and highly specific. However, EGFR mutation status tested by ARMS in plasma cannot replace a tumor tissue biopsy. Positive EGFR mutation results detected in plasma are fairly reliable, but negative results are hampered by a high rate of false negatives. Copyright © 2016. Published by Elsevier B.V.

  3. Artificial insemination of cows with semen in vitro contaminated with Neospora caninum tachyzoites failed to induce neosporosis.

    PubMed

    Canada, Nuno; Meireles, Carla Sofia; Ferreira, Paulo; Correia da Costa, José Manuel; Rocha, António

    2006-06-30

    Neosporosis is a major cause of abortion in cattle all over the world. Congenital transmission as well as horizontal transmission by ingestion of oocysts has been described. The detection of Neospora caninum DNA in bull semen warrants the investigation of possible transmission through the use of contaminated semen. In this experiment four cows were artificially inseminated with frozen-thawed semen contaminated in vitro with viable N. caninum tachyzoites (group A) and four control cows were inseminated with tachyzoites-free frozen-thawed semen, from the same bull (group B). Serum samples were collected 15 days before the artificial insemination (AI) and at days 10, 14, 21, 28, 45, 60 and 75 post-insemination. All sera samples were tested for neosporosis by direct agglutination test (DAT). Three of the cows from group A had negative DAT titers (< or =1:20) in all of the samples, while the fourth cow from this group had a low titer of antibodies (1:80) at day 10, and became negative at day 45, suggesting a stimulation of the immune system by the tachyzoites placed in uterus, rather than the induction of an infection. All of the cows from group B had negative DAT titers (< or =1:20) in all of the samples. These results suggest that transmission of neosporosis by artificial insemination with frozen-thawed semen is an unlikely event.

  4. Knowledge, actual and potential use of HIV self-sampling testing kits among MSM recruited in eight European countries.

    PubMed

    Hoyos, J; Maté, T; Indave, B I; Agustí, C; Chanos, S; Pichon, F; Kuske, M; Cigan, B; Fuertes, R; Ooms, L; Stefanescu, R; Cabeza de Vaca, C; Arranz, B; de la Fuente, L; Belza, M J

    2018-02-01

    To describe the knowledge as well as current and potential use of self-sampling kits among men who have sex with men (MSM) and to analyse their preferred biological sample and result communication method. We analyse data of MSM of HIV negative or unknown serostatus from an online survey conducted in eight countries (Belgium, Denmark, Germany, Greece, Portugal, Romania, Slovenia and Spain) between April and December 2016. It was advertised mainly in gay dating websites. We conduct a descriptive analysis of the main characteristics of the participants, and present data on indicators of knowledge, use and potential use of HIV self-sampling as well as their preferences regarding blood or saliva sample and face or non-face-to-face result communication by country of residence. A total of 8.226 participants of HIV negative or unknown serostatus were included in the analysis. Overall, 25.5% of participants knew about self-sampling (range: 18.8-47.2%) and 1.1% had used it in the past (range: 0.3-8.9%). Potential use was high, with 66.6% of all participants reporting that they would have already used it if available in the past (range: 62.1-82.1%). Most (78.6%) reported that they would prefer using a blood-based kit, and receiving the result of the test through a non-face-to-face-method (70.8%), even in the case of receiving a reactive result. The high potential use reported by MSM recruited in eight different European countries suggests that self-sampling kits are a highly acceptable testing methodology that could contribute to the promotion of HIV testing in this population. © 2018 British HIV Association.

  5. Rapid detection of MERS coronavirus-like viruses in bats: pote1ntial for tracking MERS coronavirus transmission and animal origin.

    PubMed

    Woo, Patrick C Y; Lau, Susanna K P; Chen, Yixin; Wong, Emily Y M; Chan, Kwok-Hung; Chen, Honglin; Zhang, Libiao; Xia, Ningshao; Yuen, Kwok-Yung

    2018-03-07

    Recently, we developed a monoclonal antibody-based rapid nucleocapsid protein detection assay for diagnosis of MERS coronavirus (MERS-CoV) in humans and dromedary camels. In this study, we examined the usefulness of this assay to detect other lineage C betacoronaviruses closely related to MERS-CoV in bats. The rapid MERS-CoV nucleocapsid protein detection assay was tested positive in 24 (88.9%) of 27 Tylonycteris bat CoV HKU4 (Ty-BatCoV-HKU4) RNA-positive alimentary samples of Tylonycteris pachypus and 4 (19.0%) of 21 Pipistrellus bat CoV HKU5 (Pi-BatCoV-HKU5) RNA-positive alimentary samples of Pipistrellus abramus. There was significantly more Ty-BatCoV-HKU4 RNA-positive alimentary samples than Pi-BatCoV-HKU5 RNA-positive alimentary samples that were tested positive by the rapid MERS-CoV nucleocapsid protein detection assay (P < 0.001 by Chi-square test). The rapid assay was tested negative in all 51 alimentary samples RNA-positive for alphacoronaviruses (Rhinolophus bat CoV HKU2, Myotis bat CoV HKU6, Miniopterus bat CoV HKU8 and Hipposideros batCoV HKU10) and 32 alimentary samples positive for lineage B (SARS-related Rhinolophus bat CoV HKU3) and lineage D (Rousettus bat CoV HKU9) betacoronaviruses. No significant difference was observed between the viral loads of Ty-BatCoV-HKU4/Pi-BatCoV-HKU5 RNA-positive alimentary samples that were tested positive and negative by the rapid test (Mann-Witney U test). The rapid MERS-CoV nucleocapsid protein detection assay is able to rapidly detect lineage C betacoronaviruses in bats. It detected significantly more Ty-BatCoV-HKU4 than Pi-BatCoV-HKU5 because MERS-CoV is more closely related to Ty-BatCoV-HKU4 than Pi-BatCoV-HKU5. This assay will facilitate rapid on-site mass screening of animal samples for ancestors of MERS-CoV and tracking transmission in the related bat species.

  6. Detection of occult hepatitis B and window period infection among blood donors by individual donation nucleic acid testing in a tertiary care center in South India.

    PubMed

    Keechilot, Cinzia S; Shenoy, Veena; Kumar, Anil; Biswas, Lalitha; Vijayrajratnam, Sukhithasri; Dinesh, Kavitha; Nair, Prem

    With the introduction of highly sensitive hepatitis B surface antigen immunoassay, transfusion associated HBV infection have reduced drastically but they still tend to occur due to blood donors with occult hepatitis B infection (OBI) and window period (WP) infection. Sera from, 24338 healthy voluntary blood donors were screened for HBsAg, HIV and HCV antibody using Vitros Enhanced Chemiluminescent Immunoassay. The median age of the donor population was 30 (range 18-54) with male preponderance (98%). All serologically negative samples were screened by nucleic acid testing (NAT) for viral DNA and RNA. NAT-positive samples were subjected to discriminatory NAT for HBV, HCV, and HIV and all samples positive for HBV DNA were tested for anti-HBc, anti-HBs, HBeAg. Viral load was determined using artus HBV RG PCR Kit. Of the 24,338 donors screened, 99.81% (24292/24338) were HBsAg negative of which NAT was positive for HBV DNA in 0.0205% (5/24292) donors. Four NAT positive donors had viral load of <200 IU/ml making them true cases of OBI. One NAT positive donor was negative for all antibodies making it a case of WP infection. Among OBI donors, 75% (3/4) were immune and all were negative for HBeAg. Precise HBV viral load could not be determined in all (5/5) NAT positive donors due to viral loads below the detection limit of the artus HBV RG PCR Kit. The overall incidence of OBI and WP infections was found to be low at 1 in 6503 and 1 in 24214 donations, respectively. More studies are needed to determine the actual burden of WP infections in Indian blood donors.

  7. LAMP kit for diagnosis of non-falciparum malaria in Plasmodium ovale infected patients.

    PubMed

    Cuadros, Juan; Martin Ramírez, Alexandra; González, Iveth J; Ding, Xavier C; Perez Tanoira, Ramon; Rojo-Marcos, Gerardo; Gómez-Herruz, Peña; Rubio, Jose Miguel

    2017-01-07

    Microscopy and rapid diagnosis tests have a limited sensitivity in diagnosis of malaria by Plasmodium ovale. The LAMP kit (LoopAMP®) can be used in the field without special equipment and could have an important role in malaria control programmes in endemic areas and for malaria diagnosis in returned travellers. The performance of the Pan primer of the kit in detecting malaria by P. ovale was compared with the results of standard nPCR in samples of patients returning from P. ovale endemic areas. Plasmodium ovale positive samples (29, tested by PCR and/or microscopy) and malaria negative specimens (398, tested by microscopy and PCR) were collected in different hospitals of Europe from June 2014 to March 2016 and frozen at -20 °C. Boil and spin method was used to extract DNA from all samples and amplification was performed with LoopAMP® MALARIA kit (Eiken Chemical, Japan) in an automated turbidimeter (Eiken 500). The results of LAMP read by turbidimetry and with the naked eye were compared. The kit showed a sensitivity of 100% and a specificity of 97.24% with positive and negative predictive values of 72.5 and 100%, respectively. Naked eyed readings were in accordance with turbidimetry readings (sensitivity, 92.5%, specificity, 98.96% and positive and negative predictive values, respectively, 90.24 and 99.22%). The limit of detection of LAMP assay for P. ovale was between 0.8 and 2 parasites/µl. The Pan primer of the Malaria kit LoopAMP® can detect P. ovale at very low-levels and showed a predictive negative value of 100%. This tool can be useful in malaria control and elimination programmes and in returned travellers from P. ovale endemic areas. Naked eye readings are equivalent to automated turbidimeter readings in specimens obtained with EDTA.

  8. Comparison of Antigen Detection and Nested PCR in CSF Samples of HIV Positive and Negative Patients with Suspected Cryptococcal Meningitis in a Tertiary Care Hospital.

    PubMed

    Kumari, Sunita; Verma, Rajesh Kumar; Singh, Dharmendra Prasad; Yadav, Ramakant

    2016-04-01

    The cases of cryptococcal meningitis and other forms of cryptococcosis have increased in recent time and the present scenario of the condition with significant morbidity and mortality is actually posing a serious threat to the community, so an early and prompt diagnosis is necessary to prevent serious complications and thus improving the overall disease outcome. Comparison of diagnostic efficacy of nested Polymerase Chain Reaction (PCR) with Latex Agglutination Test (LAT) in the Cerebro Spinal Fluid (CSF) samples of the cases of meningitis in HIV positive and negative cases. We have compared the diagnostic efficacy of Latex Agglutination Test (LAT) with nested Polymerase Chain Reaction (PCR) in 200 Cerebrospinal Fluid (CSF) samples, including 14 HIV positive also, in the cases of suspected cryptococcal meningitis. Nested PCR was done in all cases reporting positive by LAT and results were then compared with that of India ink and culture on Sabouraud Dextrose Agar (SDA), and the isolates were further identified by urease, nitrate and sugar assimilation tests. Of the 200 cases, including 14 HIV positive, LAT was positive in 46 cases while 154 were negative. Out of these 46 LAT positive cases, nested PCR was positive in 40 cases only, while culture and India ink was positive in 38 and 33 cases respectively. Majority of the cases, 30 (65.2%) were between age group 21-50 years, while 2 (4.3%) in 0-20, and 14 (30.4%) in 51-80 years age group. Although negative staining like India ink and nigrosin are most widely used techniques, but these suffer with subjective error. Rapid method like LAT is available but it always has the scope of false positive and negative results. In such cases nested PCR can help in establishing final diagnosis.

  9. The occurrence of Bovine viral diarrhea virus in hunter-harvested white-tailed deer (Odocoileus virginianus) in the state of Georgia, southeastern United States.

    PubMed

    Ilha, Marcia R S; Coarsey, Michele; Whittington, Lisa; Rajeev, Sreekumari; Ramamoorthy, Sheela

    2012-11-01

    The prevalence of Bovine viral diarrhea virus (BVDV) in free-ranging white-tailed deer (WTD, Odocoileus virginianus) in the state of Georgia was evaluated using ear notches collected from hunter-harvested deer during the hunting season of 2010-2011. From September to December 2010, 367 ear samples from WTD were collected from 37 counties in Georgia. The samples were from 178 (48.5%) female deer, 187 (51%) male deer, and 2 (0.5%) of unknown sex. The age of the animals varied from 6 months to 6.5 years. The age was not recorded in 34 animals (9.3%). Of the animals with known ages, 42% were under 2 years. Screening of 367 samples for BVDV using an antigen-capture enzyme-linked immunosorbent assay (AgELISA) resulted in 364 negative samples and 3 suspect samples. The 3 suspect samples were negative for BVDV reverse transcription polymerase chain reaction (RT-PCR), virus isolation, and immunohistochemistry. A subpopulation of samples (n = 89) selected from various geographical regions also tested negative for BVDV RT-PCR. In conclusion, although a few of the samples were suspect for the presence of BVDV by AgELISA, the presence of the virus within the deer population studied could not be confirmed further.

  10. Prevalence of Listeria monocytogenes in Idiazabal cheese.

    PubMed

    Arrese, E; Arroyo-Izaga, M

    2012-01-01

    Raw-milk cheese has been identified in risk assessment as a food of greater concern to public health due to listeriosis. To determine the prevalence and levels of Listeria monocytogenes in semi-hard Idiazabal cheese manufactured by different producers in the Basque Country at consumer level. A total of 51 Idiazabal cheese samples were obtained from 10 separate retail establishments, chosen by stratified random sampling. Samples were tested using the official standard ISO procedure 11290-1 for detection and enumeration methods. All cheese samples tested negative for L. monocytogenes. However, 9.8% tested positive for Listeria spp., different from L. monocytogenes. Positive samples came from two brands, two were natural and three were smoked. The presence of Listeria spss. suggests that the cheese making process and the hygiene whether at milking or during cheese making could be insufficient.

  11. Self-diagnosis of malaria by travelers and expatriates: assessment of malaria rapid diagnostic tests available on the internet.

    PubMed

    Maltha, Jessica; Gillet, Philippe; Heutmekers, Marloes; Bottieau, Emmanuel; Van Gompel, Alfons; Jacobs, Jan

    2013-01-01

    In the past malaria rapid diagnostic tests (RDTs) for self-diagnosis by travelers were considered suboptimal due to poor performance. Nowadays RDTs for self-diagnosis are marketed and available through the internet. The present study assessed RDT products marketed for self-diagnosis for diagnostic accuracy and quality of labeling, content and instructions for use (IFU). Diagnostic accuracy of eight RDT products was assessed with a panel of stored whole blood samples comprising the four Plasmodium species (n = 90) as well as Plasmodium negative samples (n = 10). IFUs were assessed for quality of description of procedure and interpretation and for lay-out and readability level. Errors in packaging and content were recorded. Two products gave false-positive test lines in 70% and 80% of Plasmodium negative samples, precluding their use. Of the remaining products, 4/6 had good to excellent sensitivity for the diagnosis of Plasmodium falciparum (98.2%-100.0%) and Plasmodium vivax (93.3%-100.0%). Sensitivity for Plasmodium ovale and Plasmodium malariae diagnosis was poor (6.7%-80.0%). All but one product yielded false-positive test lines after reading beyond the recommended reading time. Problems with labeling (not specifying target antigens (n = 3), and content (desiccant with no humidity indicator (n = 6)) were observed. IFUs had major shortcomings in description of test procedure and interpretation, poor readability and lay-out and user-unfriendly typography. Strategic issues (e.g. the need for repeat testing and reasons for false-negative tests) were not addressed in any of the IFUs. Diagnostic accuracy of RDTs for self-diagnosis was variable, with only 4/8 RDT products being reliable for the diagnosis of P. falciparum and P. vivax, and none for P. ovale and P. malariae. RDTs for self-diagnosis need improvements in IFUs (content and user-friendliness), labeling and content before they can be considered for self-diagnosis by the traveler.

  12. Self-Diagnosis of Malaria by Travelers and Expatriates: Assessment of Malaria Rapid Diagnostic Tests Available on the Internet

    PubMed Central

    Maltha, Jessica; Gillet, Philippe; Heutmekers, Marloes; Bottieau, Emmanuel; Van Gompel, Alfons; Jacobs, Jan

    2013-01-01

    Introduction In the past malaria rapid diagnostic tests (RDTs) for self-diagnosis by travelers were considered suboptimal due to poor performance. Nowadays RDTs for self-diagnosis are marketed and available through the internet. The present study assessed RDT products marketed for self-diagnosis for diagnostic accuracy and quality of labeling, content and instructions for use (IFU). Methods Diagnostic accuracy of eight RDT products was assessed with a panel of stored whole blood samples comprising the four Plasmodium species (n = 90) as well as Plasmodium negative samples (n = 10). IFUs were assessed for quality of description of procedure and interpretation and for lay-out and readability level. Errors in packaging and content were recorded. Results Two products gave false-positive test lines in 70% and 80% of Plasmodium negative samples, precluding their use. Of the remaining products, 4/6 had good to excellent sensitivity for the diagnosis of Plasmodium falciparum (98.2%–100.0%) and Plasmodium vivax (93.3%–100.0%). Sensitivity for Plasmodium ovale and Plasmodium malariae diagnosis was poor (6.7%–80.0%). All but one product yielded false-positive test lines after reading beyond the recommended reading time. Problems with labeling (not specifying target antigens (n = 3), and content (desiccant with no humidity indicator (n = 6)) were observed. IFUs had major shortcomings in description of test procedure and interpretation, poor readability and lay-out and user-unfriendly typography. Strategic issues (e.g. the need for repeat testing and reasons for false-negative tests) were not addressed in any of the IFUs. Conclusion Diagnostic accuracy of RDTs for self-diagnosis was variable, with only 4/8 RDT products being reliable for the diagnosis of P. falciparum and P. vivax, and none for P. ovale and P. malariae. RDTs for self-diagnosis need improvements in IFUs (content and user-friendliness), labeling and content before they can be considered for self-diagnosis by the traveler. PMID:23301027

  13. A field study evaluation of Petrifilm™ plates as a 24-h rapid diagnostic test for clinical mastitis on a dairy farm.

    PubMed

    Mansion-de Vries, Elisabeth Maria; Knorr, Nicole; Paduch, Jan-Hendrik; Zinke, Claudia; Hoedemaker, Martina; Krömker, Volker

    2014-03-01

    Clinical mastitis is one of the most common and expensive diseases of dairy cattle. To make an informed treatment decision, it is important to know the causative pathogen. However, no detection of bacterial growth can be made in approximately 30% of all clinical cases of mastitis. Before selecting the treatment regimen, it is important to know whether the mastitis-causing pathogen (MCP) is Gram-positive or Gram-negative. The aim of this field study was to investigate whether using two 3M Petrifilm™ products on-farm (which conveys a higher degree of sample freshness but also bears a higher risk for contamination than working in a lab) as 24-h rapid diagnostic of clinical mastitis achieved results that were comparable to the conventional microbiological diagnostic method. AerobicCount (AC)-Petrifilm™ and ColiformCount (CC)-Petrifilm™ were used to identify the total bacterial counts and Gram-negative bacteria in samples from clinical mastitis cases, respectively. Missing growth on both plates was classified as no bacterial detection. Growth only on the AC-Petrifilm™ was assessed as Gram-positive, and growth on both Petrifilm™ plates was assessed as Gram-negative bacterial growth. Additionally, milk samples were analysed by conventional microbiological diagnostic method on aesculin blood agar as a reference method. Overall, 616 samples from clinical mastitis cases were analysed. Using the reference method, Gram-positive and Gram-negative bacteria, mixed bacterial growth, contaminated samples and yeast were determined in 32.6%, 20.0%, 2.5%, 14.1% and 1.1% of the samples, respectively. In 29.7% of the samples, microbiological growth could not be identified. Using the Petrifilm™ concept, bacterial growth was detected in 59% of the culture-negative samples. The sensitivity of the Petrifilm™ for Gram-positive and Gram-negative MCP was 85.2% and 89.9%, respectively. The specificity was 75.4% for Gram-positive and 88.4% for Gram-negative MCP. For the culture-negative samples, sensitivity was 41.0% and specificity was 91.0%. The results indicate that the Petrifilm™ concept is suitable for therapeutic decision-making at the farm level or in veterinary practice. As this concept does not allow any statement about the genus or species of microorganisms, relevant MCP should be assessed periodically at the herd level with conventional microbiological diagnostics. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Evaluating the Auto-MODS Assay, a Novel Tool for Tuberculosis Diagnosis for Use in Resource-Limited Settings

    PubMed Central

    Wang, Linwei; Mohammad, Sohaib H.; Li, Qiaozhi; Rienthong, Somsak; Rienthong, Dhanida; Nedsuwan, Supalert; Mahasirimongkol, Surakameth; Yasui, Yutaka

    2014-01-01

    There is an urgent need for simple, rapid, and affordable diagnostic tests for tuberculosis (TB) to combat the great burden of the disease in developing countries. The microscopic observation drug susceptibility assay (MODS) is a promising tool to fill this need, but it is not widely used due to concerns regarding its biosafety and efficiency. This study evaluated the automated MODS (Auto-MODS), which operates on principles similar to those of MODS but with several key modifications, making it an appealing alternative to MODS in resource-limited settings. In the operational setting of Chiang Rai, Thailand, we compared the performance of Auto-MODS with the gold standard liquid culture method in Thailand, mycobacterial growth indicator tube (MGIT) 960 plus the SD Bioline TB Ag MPT64 test, in terms of accuracy and efficiency in differentiating TB and non-TB samples as well as distinguishing TB and multidrug-resistant (MDR) TB samples. Sputum samples from clinically diagnosed TB and non-TB subjects across 17 hospitals in Chiang Rai were consecutively collected from May 2011 to September 2012. A total of 360 samples were available for evaluation, of which 221 (61.4%) were positive and 139 (38.6%) were negative for mycobacterial cultures according to MGIT 960. Of the 221 true-positive samples, Auto-MODS identified 212 as positive and 9 as negative (sensitivity, 95.9%; 95% confidence interval [CI], 92.4% to 98.1%). Of the 139 true-negative samples, Auto-MODS identified 135 as negative and 4 as positive (specificity, 97.1%; 95% CI, 92.8% to 99.2%). The median time to culture positivity was 10 days, with an interquartile range of 8 to 13 days for Auto-MODS. Auto-MODS is an effective and cost-sensitive alternative diagnostic tool for TB diagnosis in resource-limited settings. PMID:25378569

  15. Fragrance patch tests prepared in advance may give false-negative reactions.

    PubMed

    Mowitz, Martin; Svedman, Cecilia; Zimerson, Erik; Bruze, Magnus

    2014-11-01

    Several of the ingredients in fragrance mix I (FM I) have been shown to evaporate from petrolatum preparations applied in test chambers to an extent that can be suspected to affect the patch test result. To compare the reactivity towards FM I and fragrance mix II (FM II) when they are applied in test chambers in advance and immediately prior to the patch test occasion. Seven hundred and ninety-five consecutive patients were simultaneously patch tested with duplicate samples of FM I and FM II. One sample was applied in the test chamber 6 days in advance (6D sample), and the other sample was applied immediately before the patients were patch tested (fresh sample). Twenty-two (2.8%) patients reacted exclusively to the fresh sample of FM I, 6 (0.7%) reacted exclusively to the 6D sample, and 22 (2.8%) reacted to both samples. The corresponding numbers for FM II were 9 (1.1%) for the fresh sample, 6 (0.7%) for the 6D sample and 12 (1.5%) for both samples. There was a statistically significant difference between the numbers of patients reacting to the fresh and 6D samples of FM I. No corresponding difference was observed for FM II. This can probably be explained by differences in volatilities between the ingredients of FM I and FM II. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. QNB: differential RNA methylation analysis for count-based small-sample sequencing data with a quad-negative binomial model.

    PubMed

    Liu, Lian; Zhang, Shao-Wu; Huang, Yufei; Meng, Jia

    2017-08-31

    As a newly emerged research area, RNA epigenetics has drawn increasing attention recently for the participation of RNA methylation and other modifications in a number of crucial biological processes. Thanks to high throughput sequencing techniques, such as, MeRIP-Seq, transcriptome-wide RNA methylation profile is now available in the form of count-based data, with which it is often of interests to study the dynamics at epitranscriptomic layer. However, the sample size of RNA methylation experiment is usually very small due to its costs; and additionally, there usually exist a large number of genes whose methylation level cannot be accurately estimated due to their low expression level, making differential RNA methylation analysis a difficult task. We present QNB, a statistical approach for differential RNA methylation analysis with count-based small-sample sequencing data. Compared with previous approaches such as DRME model based on a statistical test covering the IP samples only with 2 negative binomial distributions, QNB is based on 4 independent negative binomial distributions with their variances and means linked by local regressions, and in the way, the input control samples are also properly taken care of. In addition, different from DRME approach, which relies only the input control sample only for estimating the background, QNB uses a more robust estimator for gene expression by combining information from both input and IP samples, which could largely improve the testing performance for very lowly expressed genes. QNB showed improved performance on both simulated and real MeRIP-Seq datasets when compared with competing algorithms. And the QNB model is also applicable to other datasets related RNA modifications, including but not limited to RNA bisulfite sequencing, m 1 A-Seq, Par-CLIP, RIP-Seq, etc.

  17. Prevalence of naturally occurring antibodies against dog erythrocyte antigen 7 in a population of dog erythrocyte antigen 7-negative dogs from Spain and Italy.

    PubMed

    Spada, Eva; Proverbio, Daniela; Viñals Flórez, Luis Miguel; Del Rosario Perlado Chamizo, Maria; Serra Y Gómez de la Serna, Blanca; Perego, Roberta; Baggiani, Luciana

    2016-08-01

    OBJECTIVE To determine the prevalence of naturally occurring anti-dog erythrocyte antigen (DEA) 7 antibodies in DEA 7-negative dogs from Spain and Italy. ANIMALS 252 DEA 7-negative dogs from a population of 312 dogs that were previously tested for DEA 1, DEA 4, and DEA 7. PROCEDURES A plasma sample was obtained from each dog and evaluated for anti-DEA 7 antibodies by the use of gel column agglutination. Each plasma sample underwent major crossmatching with RBCs from DEA 7-positive dogs. Samples that resulted in agglutination were then crossmatched with RBCs from DEA 1-negative, DEA 4-positive, and DEA 7-negative dogs to confirm the presence of anti-DEA 7 antibodies. Results were then used to calculate the risk for a delayed transfusion reaction in a DEA 7-negative dog with anti-DEA 7 antibodies after a transfusion with blood that was not crossmatched or typed for DEA 7. RESULTS 96 of 252 (38.1%) plasma samples contained anti-DEA 7 antibodies. A DEA 7-negative dog with anti-DEA 7 antibodies had a 5.9% chance of developing a delayed hemolytic reaction after transfusion with blood not crossmatched or typed for DEA 7. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that canine blood used for transfusion should be crossmatched with the blood or plasma of the intended recipient prior to transfusion to minimize the likelihood that the recipient will develop a hemolytic reaction associated with anti-DEA 7 antibodies. Ideal canine blood donors should be negative for both DEA 1 and DEA 7.

  18. The efficacy of protoporphyrin as a predictive biomarker for lead exposure in canvasback ducks: effect of sample storage time

    USGS Publications Warehouse

    Franson, J.C.; Hohman, W.L.; Moore, J.L.; Smith, M.R.

    1996-01-01

    We used 363 blood samples collected from wild canvasback dueks (Aythya valisineria) at Catahoula Lake, Louisiana, U.S.A. to evaluate the effect of sample storage time on the efficacy of erythrocytic protoporphyrin as an indicator of lead exposure. The protoporphyrin concentration of each sample was determined by hematofluorometry within 5 min of blood collection and after refrigeration at 4 °C for 24 and 48 h. All samples were analyzed for lead by atomic absorption spectrophotometry. Based on a blood lead concentration of ≥0.2 ppm wet weight as positive evidence for lead exposure, the protoporphyrin technique resulted in overall error rates of 29%, 20%, and 19% and false negative error rates of 47%, 29% and 25% when hematofluorometric determinations were made on blood at 5 min, 24 h, and 48 h, respectively. False positive error rates were less than 10% for all three measurement times. The accuracy of the 24-h erythrocytic protoporphyrin classification of blood samples as positive or negative for lead exposure was significantly greater than the 5-min classification, but no improvement in accuracy was gained when samples were tested at 48 h. The false negative errors were probably due, at least in part, to the lag time between lead exposure and the increase of blood protoporphyrin concentrations. False negatives resulted in an underestimation of the true number of canvasbacks exposed to lead, indicating that hematofluorometry provides a conservative estimate of lead exposure.

  19. Limitations of Rapid Diagnostic Testing in Patients with Suspected Malaria: A Diagnostic Accuracy Evaluation from Swaziland, a Low-Endemicity Country Aiming for Malaria Elimination

    PubMed Central

    Ranadive, Nikhil; Kunene, Simon; Darteh, Sarah; Ntshalintshali, Nyasatu; Nhlabathi, Nomcebo; Dlamini, Nomcebo; Chitundu, Stanley; Saini, Manik; Murphy, Maxwell; Soble, Adam; Schwartz, Alanna; Greenhouse, Bryan

    2017-01-01

    Abstract Background. The performance of Plasmodium falciparum–specific histidine-rich protein 2–based rapid diagnostic tests (RDTs) to evaluate suspected malaria in low-endemicity settings has not been well characterized. Methods. Using dried blood spot samples from patients with suspected malaria at 37 health facilities from 2012 to 2014 in the low-endemicity country of Swaziland, we investigated the diagnostic accuracy of histidine-rich protein 2–based RDTs using qualitative polymerase chain reaction (PCR) (nested PCR targeting the cytochrome b gene) and quantitative PCR as reference standards. To explore reasons for false-negative and/or false-positive results, we used pfhrp2/3-specific PCR and logistic regression analyses of potentially associated epidemiological factors. Results. From 1353 patients, 93.0% of RDT-positive (n = 185) and 31.2% of RDT-negative samples (n = 340) were available and selected for testing. Compared with nested PCR, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of RDTs were 51.7%, 94.1%, 67.3%, and 89.1%, respectively. After exclusion of samples with parasite densities <100/μL, which accounted for 75.7% of false-negative results and 33.3% of PCR-detectable infections, the sensitivity, specificity, PPV, and NPV were 78.8%, 93.7%, 62.3%, and 97.1%. Deletions of pfhrp2 were not detected. False-positivity was more likely during the second year and was not associated with demographics, recent malaria, health facility testing characteristics, or potential DNA degradation. Conclusions. In the low-transmission setting of Swaziland, we demonstrated low sensitivity of RDT for malaria diagnosis, owing to an unexpectedly high proportion of low-density infection among symptomatic subjects. The PPV was also low, requiring further investigation. A more accurate point-of-care diagnostic may be needed to support malaria elimination efforts. PMID:28369268

  20. Limitations of Rapid Diagnostic Testing in Patients with Suspected Malaria: A Diagnostic Accuracy Evaluation from Swaziland, a Low-Endemicity Country Aiming for Malaria Elimination.

    PubMed

    Ranadive, Nikhil; Kunene, Simon; Darteh, Sarah; Ntshalintshali, Nyasatu; Nhlabathi, Nomcebo; Dlamini, Nomcebo; Chitundu, Stanley; Saini, Manik; Murphy, Maxwell; Soble, Adam; Schwartz, Alanna; Greenhouse, Bryan; Hsiang, Michelle S

    2017-05-01

    The performance of Plasmodium falciparum-specific histidine-rich protein 2-based rapid diagnostic tests (RDTs) to evaluate suspected malaria in low-endemicity settings has not been well characterized. Using dried blood spot samples from patients with suspected malaria at 37 health facilities from 2012 to 2014 in the low-endemicity country of Swaziland, we investigated the diagnostic accuracy of histidine-rich protein 2-based RDTs using qualitative polymerase chain reaction (PCR) (nested PCR targeting the cytochrome b gene) and quantitative PCR as reference standards. To explore reasons for false-negative and/or false-positive results, we used pfhrp2/3-specific PCR and logistic regression analyses of potentially associated epidemiological factors. From 1353 patients, 93.0% of RDT-positive (n = 185) and 31.2% of RDT-negative samples (n = 340) were available and selected for testing. Compared with nested PCR, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of RDTs were 51.7%, 94.1%, 67.3%, and 89.1%, respectively. After exclusion of samples with parasite densities <100/μL, which accounted for 75.7% of false-negative results and 33.3% of PCR-detectable infections, the sensitivity, specificity, PPV, and NPV were 78.8%, 93.7%, 62.3%, and 97.1%. Deletions of pfhrp2 were not detected. False-positivity was more likely during the second year and was not associated with demographics, recent malaria, health facility testing characteristics, or potential DNA degradation. In the low-transmission setting of Swaziland, we demonstrated low sensitivity of RDT for malaria diagnosis, owing to an unexpectedly high proportion of low-density infection among symptomatic subjects. The PPV was also low, requiring further investigation. A more accurate point-of-care diagnostic may be needed to support malaria elimination efforts. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  1. The New Xpert MTB/RIF Ultra: Improving Detection of Mycobacterium tuberculosis and Resistance to Rifampin in an Assay Suitable for Point-of-Care Testing

    PubMed Central

    Simmons, Ann Marie; Rowneki, Mazhgan; Parmar, Heta; Cao, Yuan; Ryan, Jamie; Banada, Padmapriya P.; Deshpande, Srinidhi; Shenai, Shubhada; Gall, Alexander; Glass, Jennifer; Krieswirth, Barry; Schumacher, Samuel G.; Nabeta, Pamela; Tukvadze, Nestani; Rodrigues, Camilla; Skrahina, Alena; Tagliani, Elisa; Cirillo, Daniela M.; Davidow, Amy; Denkinger, Claudia M.; Persing, David; Kwiatkowski, Robert; Jones, Martin

    2017-01-01

    ABSTRACT The Xpert MTB/RIF assay (Xpert) is a rapid test for tuberculosis (TB) and rifampin resistance (RIF-R) suitable for point-of-care testing. However, it has decreased sensitivity in smear-negative sputum, and false identification of RIF-R occasionally occurs. We developed the Xpert MTB/RIF Ultra assay (Ultra) to improve performance. Ultra and Xpert limits of detection (LOD), dynamic ranges, and RIF-R rpoB mutation detection were tested on Mycobacterium tuberculosis DNA or sputum samples spiked with known numbers of M. tuberculosis H37Rv or Mycobacterium bovis BCG CFU. Frozen and prospectively collected clinical samples from patients suspected of having TB, with and without culture-confirmed TB, were also tested. For M. tuberculosis H37Rv, the LOD was 15.6 CFU/ml of sputum for Ultra versus 112.6 CFU/ml of sputum for Xpert, and for M. bovis BCG, it was 143.4 CFU/ml of sputum for Ultra versus 344 CFU/ml of sputum for Xpert. Ultra resulted in no false-positive RIF-R specimens, while Xpert resulted in two false-positive RIF-R specimens. All RIF-R-associated M. tuberculosis rpoB mutations tested were identified by Ultra. Testing on clinical sputum samples, Ultra versus Xpert, resulted in an overall sensitivity of 87.5% (95% confidence interval [CI], 82.1, 91.7) versus 81.0% (95% CI, 74.9, 86.2) and a sensitivity on sputum smear-negative samples of 78.9% (95% CI, 70.0, 86.1) versus 66.1% (95% CI, 56.4, 74.9). Both tests had a specificity of 98.7% (95% CI, 93.0, 100), and both had comparable accuracies for detection of RIF-R in these samples. Ultra should significantly improve TB detection, especially in patients with paucibacillary disease, and may provide more-reliable RIF-R detection. PMID:28851844

  2. Legionella pneumophila serogroup 3 infection: importance of serology.

    PubMed

    Khanna, N; Meikle, A; Gillespie, L; Edwards, G; Lindsay, D

    2012-08-01

    We present a case of Legionella pneumophila serogroup 3 (LP3) infection in a patient with severe community-acquired pneumonia (CAP). The diagnosis was complicated by an initial equivocal L. pneumophila urinary antigen test, followed by two negative samples. LP3 was cultured from a sputum sample and the diagnosis was confirmed by serology 15 days into the admission. This case highlights the importance of considering non-LP1 serogroups as causes of CAP and the role of serological testing in diagnosis.

  3. Cumulative Risk, Negative Emotionality, and Emotion Regulation as Predictors of Social Competence in Transition to School: A Mediated Moderation Model

    ERIC Educational Resources Information Center

    Chang, Hyein; Shelleby, Elizabeth C.; Cheong, JeeWon; Shaw, Daniel S.

    2012-01-01

    The goals of this study were to examine the additive and interactive effects of cumulative risk and child negative emotionality on children's social competence in the transition from preschool to school and to test whether these associations were mediated by child emotion regulation within a sample of 310 low-income, ethnically diverse boys.…

  4. Concordance of anaplastic lymphoma kinase (ALK) gene rearrangements between circulating tumor cells and tumor in non-small cell lung cancer

    PubMed Central

    Lim, Tony KH; Tan, Daniel Shao-Weng; Chua, Yong Wei; Ang, Mei Kim; Pang, Brendan; Lim, Chwee Teck; Takano, Angela; Lim, Alvin Soon-Tiong; Leong, Man Chun; Lim, Wan-Teck

    2016-01-01

    Anaplastic lymphoma kinase (ALK) gene rearrangement in non-small cell lung cancer (NSCLC) is routinely evaluated by fluorescent in-situ hybridization (FISH) testing on biopsy tissues. Testing can be challenging however, when suitable tissue samples are unavailable. We examined the relevance of circulating tumor cells (CTC) as a surrogate for biopsy-based FISH testing. We assessed paired tumor and CTC samples from patients with ALK rearranged lung cancer (n = 14), ALK-negative lung cancer (n = 12), and healthy controls (n = 5) to derive discriminant CTC counts, and to compare ALK rearrangement patterns. Blood samples were enriched for CTCs to be used for ALK FISH testing. ALK-positive CTCs counts were higher in ALK-positive NSCLC patients (3–15 cells/1.88 mL of blood) compared with ALK-negative NSCLC patients and healthy donors (0–2 cells/1.88 mL of blood). The latter range was validated as the ‘false positive’ cutoff for ALK FISH testing of CTCs. ALK FISH signal patterns observed on tumor biopsies were recapitulated in CTCs in all cases. Sequential CTC counts in an index case of lung cancer with no evaluable tumor tissue treated with crizotinib showed six, three and eleven ALK-positive CTCs per 1.88 mL blood at baseline, partial response and post-progression time points, respectively. Furthermore, ALK FISH rearrangement suggestive of gene copy number increase was observed in CTCs following progression. Recapitulation of ALK rearrangement patterns in the tumor on CTCs, suggested that CTCs might be used to complement tissue-based ALK testing in NSCLC to guide ALK-targeted therapy when suitable tissue biopsy samples are unavailable for testing. PMID:26993609

  5. Use of ferric chloride to identify salicylate-containing poisons.

    PubMed

    Hoffman, Robert J; Nelson, Lewis S; Hoffman, Robert S

    2002-01-01

    Ferric chloride (FeCl3) is used to qualitatively test the urine of patients with presumed salicylate exposure. FeCl3 testing of an unidentified poison might provide evidence of salicylate exposure in situations where FeCl3 urine testing cannot be used. Such situations include the absence of a urine sample, immediately after ingestion before urine contains a detectable quantity of salicylate, or for patients chronically using salicylatesfor which FeCl3 testing is unhelpful. This study seeks to determine if FeCl3 can be used to identify salicylate-containing products. We assessed the reactivity of FeCl3 with commercially available salicylate-containing products. We applied 0.1 mL of 10% FeCl3 solution to each of 15 various salicylate-containing products including: regular and buffered acetylsalicylic acid, bismuth subsalicylate, methylsalicylate, physostigmine salicylate, salicylic acid, trolamine salicylate, and herbal tablets with salicin-containing white willow bark (Salix sp.). These products tested were: regular and enteric-coatedpills (n = 4), powder (n = 1), topical creams (n = 5), topical liquids (n = 4), and intravenous solution (n = 1). FeCl3 was applied to crushed tablets and added directly to liquids and creams. Fifteen salicylate-free controls including liquids, pills, and creams similar in appearance to experimental samples were also tested. Three blinded physiciansfamiliar with FeCl3 testing independently observed the addition of FeCl3 to each sample and rated a positive or negative result. All salicylate-containing products were interpreted to be clearly FeCl3 positive and all control samples were interpreted to be clearly FeCl3 negative. Salicylate-containing products may be identified using FeCl33. When using FeCl3

  6. Evaluation of a Dual ALK/ROS1 Fluorescent In Situ Hybridization Test in Non-Small-cell Lung Cancer.

    PubMed

    Ginestet, Florent; Lambros, Laetitia; Le Flahec, Glen; Marcorelles, Pascale; Uguen, Arnaud

    2018-05-05

    Several therapeutics targets have emerged to treat patients with non-small-cell lung carcinoma (NSCLC), with numerous biomarkers available to test for treatment choices. Minimum tumor wastage is necessary to permit the analysis of every potentially relevant target. Searching for targetable ALK and ROS1 rearrangements is now mandatory in NSCLC. In the present study, we evaluated the performance of a dual ALK/ROS1 fluorescent in situ hybridization (FISH) probe that concurrently analyzed the 2 oncogenes on a same FISH slide. We used the FlexISH ALK/ROS1 DistinguISH Probe (Zytovision, Bremerhaven, Germany) to analyze a set of 28 formalin-fixed paraffin-embedded NSCLC tumor samples enriched in tumors with ALK- and ROS1-rearranged status. The dual ALK/ROS1 FISH probe test results were fully concordant with the results of previous single ALK and ROS1 FISH tests (15 ALK and 3 ROS1 rearrangements) without any false-positive results. Dual- and single-probe FISH test results were also concordant regarding the unusual ALK FISH patterns. These included 1 sample that had negative FISH results with diffuse single 5'-ALK signals and positive ALK immunohistochemistry findings in a patient with a response to crizotinib, 2 paired samples with high percentages of ALK FISH-rearranged nuclei despite negative ALK immunohistochemistry findings, and ALK FISH-positive samples from 2 patients lacking a response to crizotinib therapy despite concordant ALK FISH and immunohistochemistry-positive results. The dual ALK/ROS1 FISH probe test is a valuable tool to search concurrently for both ALK and ROS1 rearrangements on a same FISH slide and could help to spare tumor tissue for other biomarkers tests. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Concordance of anaplastic lymphoma kinase (ALK) gene rearrangements between circulating tumor cells and tumor in non-small cell lung cancer.

    PubMed

    Tan, Chye Ling; Lim, Tse Hui; Lim, Tony Kh; Tan, Daniel Shao-Weng; Chua, Yong Wei; Ang, Mei Kim; Pang, Brendan; Lim, Chwee Teck; Takano, Angela; Lim, Alvin Soon-Tiong; Leong, Man Chun; Lim, Wan-Teck

    2016-04-26

    Anaplastic lymphoma kinase (ALK) gene rearrangement in non-small cell lung cancer (NSCLC) is routinely evaluated by fluorescent in-situ hybridization (FISH) testing on biopsy tissues. Testing can be challenging however, when suitable tissue samples are unavailable. We examined the relevance of circulating tumor cells (CTC) as a surrogate for biopsy-based FISH testing. We assessed paired tumor and CTC samples from patients with ALK rearranged lung cancer (n = 14), ALK-negative lung cancer (n = 12), and healthy controls (n = 5) to derive discriminant CTC counts, and to compare ALK rearrangement patterns. Blood samples were enriched for CTCs to be used for ALK FISH testing. ALK-positive CTCs counts were higher in ALK-positive NSCLC patients (3-15 cells/1.88 mL of blood) compared with ALK-negative NSCLC patients and healthy donors (0-2 cells/1.88 mL of blood). The latter range was validated as the 'false positive' cutoff for ALK FISH testing of CTCs. ALK FISH signal patterns observed on tumor biopsies were recapitulated in CTCs in all cases. Sequential CTC counts in an index case of lung cancer with no evaluable tumor tissue treated with crizotinib showed six, three and eleven ALK-positive CTCs per 1.88 mL blood at baseline, partial response and post-progression time points, respectively. Furthermore, ALK FISH rearrangement suggestive of gene copy number increase was observed in CTCs following progression. Recapitulation of ALK rearrangement patterns in the tumor on CTCs, suggested that CTCs might be used to complement tissue-based ALK testing in NSCLC to guide ALK-targeted therapy when suitable tissue biopsy samples are unavailable for testing.

  8. Sensitivity, specificity and comparison of three commercially available immunological tests in the diagnosis of Cryptosporidium species in animals.

    PubMed

    Danišová, Olga; Halánová, Monika; Valenčáková, Alexandra; Luptáková, Lenka

    The study was conducted to compare the specificity of immunological diagnostic methods used for the diagnosis of Cryptosporidium species capable of causing life-threatening infection in both immunosuppressed and immunocompetent patients. For the detection of Cryptosporidium species in 79 animals with diarrhoea, we used three Copro-antigen tests: RIDASCREEN ® Cryptosporidium test, Cryptosporidium 2nd Generation (ELISA) and RIDA ® QUICK Cryptosporidium. For immunoassays we used positive and negative samples detected by means of polymerase chain reaction and validated by sequencing and nested polymerase chain reaction to confirm the presence six different species of Cryptosporidium species. Prevalence of cryptosporidiosis in the entire group determined by enzyme immunoassay, enzyme linked immunosorbent assay, immuno-chromatographic test and polymerase chain reaction was 34.17%, 27.84%, 6.33% and 27.84%, respectively. Sensitivity of animal samples with enzyme immunoassay, enzyme linked immunosorbent assay, and immuno-chromatographic test was 63.6%, 40.9% and 22.7%, resp., when questionable samples were considered positive, whereas specificity of enzyme immunoassay, enzyme linked immunosorbent assay and immuno-chromatographic test was 75.9%, 78.9% and 100%, respectively. Positive predictive values and negative predictive values were different for all the tests. These differences results are controversial and therefore reliability and reproducibility of immunoassays as the only diagnostic method is questionable. The use of various Cryptosporidium species in diagnosis based on immunological testing and different results obtained by individual tests indicate potential differences in Copro-antigens produced by individual Cryptosporidium species. Copyright © 2017 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.

  9. Positive Attributes Buffer the Negative Associations Between Low Intelligence and High Psychopathology With Educational Outcomes.

    PubMed

    Hoffmann, Mauricio Scopel; Leibenluft, Ellen; Stringaris, Argyris; Laporte, Paola Paganella; Pan, Pedro Mario; Gadelha, Ary; Manfro, Gisele Gus; Miguel, Eurípedes Constantino; Rohde, Luis Augusto; Salum, Giovanni Abrahão

    2016-01-01

    This study examines the extent to which children's positive attributes are distinct from psychopathology. We also investigate whether positive attributes change or "buffer" the impact of low intelligence and high psychopathology on negative educational outcomes. In a community sample of 2,240 children (6-14 years of age), we investigated associations among positive attributes, psychopathology, intelligence, and negative educational outcomes. Negative educational outcomes were operationalized as learning problems and poor academic performance. We tested the discriminant validity of psychopathology versus positive attributes using confirmatory factor analysis (CFA) and propensity score matching analysis (PSM), and used generalized estimating equations (GEE) models to test main effects and interactions among predictors of educational outcomes. According to both CFA and PSM, positive attributes and psychiatric symptoms were distinct constructs. Positive attributes were associated with lower levels of negative educational outcomes, independent of intelligence and psychopathology. Positive attributes buffer the negative effects of lower intelligence on learning problems, and higher psychopathology on poor academic performance. Children's positive attributes are associated with lower levels of negative school outcomes. Positive attributes act both independently and by modifying the negative effects of low intelligence and high psychiatric symptoms on educational outcomes. Subsequent research should test interventions designed to foster the development of positive attributes in children at high risk for educational problems. Copyright © 2016 American Academy of Child and Adolescent Psychiatry. All rights reserved.

  10. Positive Attributes Buffer the Negative Associations Between Low Intelligence and High Psychopathology With Educational Outcomes

    PubMed Central

    Hoffmann, Mauricio Scopel; Leibenluft, Ellen; Stringaris, Argyris; Laporte, Paola Paganella; Pan, Pedro Mario; Gadelha, Ary; Manfro, Gisele Gus; Miguel, Eurípedes Constantino; Rohde, Luis Augusto; Salum, Giovanni Abrahão

    2016-01-01

    Objective This study examines the extent to which children’s positive attributes are distinct from psychopathology. We also investigate whether positive attributes change or “buffer” the impact of low intelligence and high psychopathology on negative educational outcomes. Method In a community sample of 2,240 children (6–14 years of age), we investigated associations among positive attributes, psychopathology, intelligence, and negative educational outcomes. Negative educational outcomes were operationalized as learning problems and poor academic performance. We tested the discriminant validity of psychopathology versus positive attributes using confirmatory factor analysis (CFA) and propensity score matching analysis (PSM), and used generalized estimating equations (GEE) models to test main effects and interactions among predictors of educational outcomes. Results According to both CFA and PSM, positive attributes and psychiatric symptoms were distinct constructs. Positive attributes were associated with lower levels of negative educational outcomes, independent of intelligence and psychopathology. Positive attributes buffer the negative effects of lower intelligence on learning problems, and higher psychopathology on poor academic performance. Conclusion Children’s positive attributes are associated with lower levels of negative school outcomes. Positive attributes act both independently and by modifying the negative effects of low intelligence and high psychiatric symptoms on educational outcomes. Subsequent research should test interventions designed to foster the development of positive attributes in children at high risk for educational problems. PMID:26703909

  11. The miRNA and mRNA Signatures of Peripheral Blood Cells in Humans Infected with Trypanosoma brucei gambiense.

    PubMed

    Lueong, Smiths; Leong, Smiths; Simo, Gustave; Camara, Mamadou; Jamonneau, Vincent; Kabore, Jacques; Ilboudo, Hamidou; Bucheton, Bruno; Hoheisel, Jörg D; Clayton, Christine

    2013-01-01

    Simple, reliable tools for diagnosis of human African Trypanosomiases could ease field surveillance and enhance patient care. In particular, current methods to distinguish patients with (stage II) and without (stage I) brain involvement require samples of cerebrospinal fluid. We describe here an exploratory study to find out whether miRNAs from peripheral blood leukocytes might be useful in diagnosis of human trypanosomiasis, or for determining the stage of the disease. Using microarrays, we measured miRNAs in samples from Trypanosoma brucei gambiense-infected patients (9 stage I, 10 stage II), 8 seronegative parasite-negative controls and 12 seropositive, but parasite-negative subjects. 8 miRNAs (out of 1205 tested) showed significantly lower expression in patients than in seronegative, parasite-negative controls, and 1 showed increased expression. There were no clear differences in miRNAs between patients in different disease stages. The miRNA profiles could not distinguish seropositive, but parasitologically negative samples from controls and results within this group did not correlate with those from the trypanolysis test. Some of the regulated miRNAs, or their predicted mRNA targets, were previously reported changed during other infectious diseases or cancer. We conclude that the changes in miRNA profiles of peripheral blood lymphocytes in human African trypanosomiasis are related to immune activation or inflammation, are probably disease-non-specific, and cannot be used to determine the disease stage. The approach has little promise for diagnostics but might yield information about disease pathology.

  12. Evaluation of the Palutop+4 malaria rapid diagnostic test in a non-endemic setting.

    PubMed

    van Dijk, David P J; Gillet, Philippe; Vlieghe, Erika; Cnops, Lieselotte; van Esbroeck, Marjan; Jacobs, Jan

    2009-12-12

    Palutop+4 (All. Diag, Strasbourg, France), a four-band malaria rapid diagnostic test (malaria RDT) targeting the histidine-rich protein 2 (HRP-2), Plasmodium vivax-specific parasite lactate dehydrogenase (Pv-pLDH) and pan Plasmodium-specific pLDH (pan-pLDH) was evaluated in a non-endemic setting on stored whole blood samples from international travellers suspected of malaria. Microscopy corrected by PCR was the reference method. Samples include those infected by Plasmodium falciparum (n = 323), Plasmodium vivax (n = 97), Plasmodium ovale (n = 73) and Plasmodium malariae (n = 25) and 95 malaria negative samples. The sensitivities for the diagnosis of P. falciparum, P. vivax, P. malariae and P. ovale were 85.1%, 66.0%, 32.0% and 5.5%. Sensitivities increased at higher parasite densities and reached 90.0% for P. falciparum >100/microl and 83.8% for P. vivax > 500/microl. Fourteen P. falciparum samples reacted with the Pv-pLDH line, one P. vivax sample with the HRP-2 line, and respectively two and four P. ovale and P. malariae samples reacted with the HRP-2 line. Two negative samples gave a signal with the HRP-2 line. Faint and weak line intensities were observed for 129/289 (44.6%) HRP-2 lines in P. falciparum samples, for 50/64 (78.1%) Pv-pLDH lines in P. vivax samples and for 9/13 (69.2%) pan-pLDH lines in P. ovale and P. malariae samples combined. Inter-observer reliabilities for positive and negative readings were excellent for the HRP-2 and Pv-pLDH lines (overall agreement > 92.0% and kappa-values for each pair of readers >or= 0.88), and good for the pan-pLDH line (85.5% overall agreement and kappa-values >or= 0.74). Palutop+4 performed moderately for the detection of P. falciparum and P. vivax, but sensitivities were lower than those of three-band malaria RDTs.

  13. Structural validation of the Self-Compassion Scale with a German general population sample

    PubMed Central

    Kwakkenbos, Linda; Moran, Chelsea; Thombs, Brett; Albani, Cornelia; Bourkas, Sophia; Zenger, Markus; Brahler, Elmar; Körner, Annett

    2018-01-01

    Background Published validation studies have reported different factor structures for the Self-Compassion Scale (SCS). The objective of this study was to assess the factor structure of the SCS in a large general population sample representative of the German population. Methods A German population sample completed the SCS and other self-report measures. Confirmatory factor analysis (CFA) in MPlus was used to test six models previously found in factor analytic studies (unifactorial model, two-factor model, three-factor model, six-factor model, a hierarchical (second order) model with six first-order factors and two second-order factors, and a model with arbitrarily assigned items to six factors). In addition, three bifactor models were also tested: bifactor model #1 with two group factors (SCS positive items, called SCS positive) and SCS negative items, called SCS negative) and one general factor (overall SCS); bifactor model #2, which is a two-tier model with six group factors, three (SCS positive subscales) corresponding to one general dimension (SCS positive) and three (SCS negative subscales) corresponding to the second general dimension (SCS negative); bifactor model #3 with six group factors (six SCS subscales) and one general factor (overall SCS). Results The two-factor model, the six-factor model, and the hierarchical model showed less than ideal, but acceptable fit. The model fit indices for these models were comparable, with no apparent advantage of the six-factor model over the two-factor model. The one-factor model, the three-factor model, and bifactor model #3 showed poor fit. The other two bifactor models showed strong support for two factors: SCS positive and SCS negative. Conclusion The main results of this study are that, among the German general population, six SCS factors and two SCS factors fit the data reasonably well. While six factors can be modelled, the three negative factors and the three positive factors, respectively, did not reflect reliable or meaningful variance beyond the two summative positive and negative item factors. As such, we recommend the use of two subscale scores to capture a positive factor and a negative factor when administering the German SCS to general population samples and we strongly advise against the use of a total score across all SCS items. PMID:29408888

  14. Antibiotic Screening of Urine Culture for Internal Quality Audit at Amrita Hospital, Kochi.

    PubMed

    Suresh, Aswathy; Gopinathan, Anusha; Dinesh, Kavitha R; Kumar, Anil

    2017-07-01

    Urine antimicrobial activity is a seldom analysed laboratory test which greatly impacts the quantification of urine specimens. Presence of antimicrobial activity in the urine reduces the bacterial load in these specimens. Hence, the chances of erroneously reporting insignificant bacteriuria can be reduced on analysis of the antimicrobial activity in urine. The aim of the study was to measure the antimicrobial activity of urine samples obtained from patients in a tertiary care hospital. A total of 100 urine specimens were collected from the study group. Tests like wet mount, Gram staining and culture were performed. Antimicrobial susceptibility testing was done on the bacteria isolated from each specimen. The urine specimens were reported as significant bacteriuria (>105 Colony Forming Unit (CFU)/ml) and insignificant bacteriuria (<105 CFU/ml - clean catch midstream urine; <102 CFU/ml - catheterized urine sample) according to the CFU/ml. Staphylococcus aureus ATCC ® 25923 ™ and Escherichia coli ATCC ® 25922 ™ were used to identify the presence of antimicrobial activity in the urine sample by Urine Anti-Bacterial substance Assay (UABA). McNemar test was used for statistical analysis using Statistical Package for the Social Sciences (SPSS) version 21.0. On analysis of the antimicrobial activity of urine sample with the prior antibiotic history of the patients, 17 were true positives and 43 were true negatives. Twenty six of samples with UABA positivity were culture negative and 28 samples with UABA positivity were culture positive. Sensitivity and specificity of the test was 85% and 53.8% respectively. Accuracy of the test was 60%. The p-value of UABA was <0.001. Enterobacteriaceae was the most common bacterial family isolated from the urine specimens. A total of 85% patients responded to treatment. Presence of antimicrobial activity in urine has a great impact on the interpretation of urine culture reports. Identification of urine antimicrobial activity helps in evaluating the quantification of bacterial growth reported in urine culture. It facilitates speedy recovery of patients by early administration of antibiotics.

  15. Estimation of infection prevalence and sensitivity in a stratified two-stage sampling design employing highly specific diagnostic tests when there is no gold standard.

    PubMed

    Miller, Ezer; Huppert, Amit; Novikov, Ilya; Warburg, Alon; Hailu, Asrat; Abbasi, Ibrahim; Freedman, Laurence S

    2015-11-10

    In this work, we describe a two-stage sampling design to estimate the infection prevalence in a population. In the first stage, an imperfect diagnostic test was performed on a random sample of the population. In the second stage, a different imperfect test was performed in a stratified random sample of the first sample. To estimate infection prevalence, we assumed conditional independence between the diagnostic tests and develop method of moments estimators based on expectations of the proportions of people with positive and negative results on both tests that are functions of the tests' sensitivity, specificity, and the infection prevalence. A closed-form solution of the estimating equations was obtained assuming a specificity of 100% for both tests. We applied our method to estimate the infection prevalence of visceral leishmaniasis according to two quantitative polymerase chain reaction tests performed on blood samples taken from 4756 patients in northern Ethiopia. The sensitivities of the tests were also estimated, as well as the standard errors of all estimates, using a parametric bootstrap. We also examined the impact of departures from our assumptions of 100% specificity and conditional independence on the estimated prevalence. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Infectious hematopoietic necrosis virus detected by separation and incubation of cells from salmonid cavity fluid.

    USGS Publications Warehouse

    Mulcahy, D.; Batts, W.N.

    1987-01-01

    Infectious hematopoietic necrosis (IHN) virus is usually detected by inoculating susceptible cell cultures with cavity ("ovarian") fluid (CF) from spawning females. We identified additional adult carriers of virus in spawning populations of steelhead trout (Salmo gairdneri) and sockeye salmon (Oncorhynchus nerka) by collecting nonerythrocytic cells from CF samples by low-speed centrifugation, culturing the cells for at least 7 d at 15 °C, and then testing the culture medium for virus. Virus appeared in the cultured cells from some samples of CF that remained negative during incubation. In additional samples of CF from these species, the virus titer increased in cultured cells compared with the titer in the original CF sample. With chinook salmon (O.tshawytscha), no negative samples converted to positive during incubation, but the virus titer was retained in incubated CF cells, but not in cell-free CF.

  17. Sequential sampling of ribes populations in the control of white pine blister rust (Cronartium ribicola Fischer) in California

    Treesearch

    Harold R. Offord

    1966-01-01

    Sequential sampling based on a negative binomial distribution of ribes populations required less than half the time taken by regular systematic line transect sampling in a comparison test. It gave the same control decision as the regular method in 9 of 13 field trials. A computer program that permits sequential plans to be built readily for other white pine regions is...

  18. Acceptability of unsupervised HPV self-sampling using written instructions.

    PubMed

    Waller, J; McCaffery, K; Forrest, S; Szarewski, A; Cadman, L; Austin, J; Wardle, J

    2006-01-01

    The study measured the acceptability of self-sampling for human papillomavirus (HPV) testing in the context of cervical cancer screening. Women carried out self-sampling unsupervised, using a written instruction sheet. Participants were women attending either a family planning clinic or a primary care trust for routine cervical screening. Women (n = 902) carried out self-sampling for HPV testing and then a clinician did a routine cervical smear and HPV test. Immediately after having the two tests, participants completed a measure of acceptability for both tests, and answered questions about ease of using the instruction sheet and willingness to use self-sampling in the future. The majority of women found self-sampling more acceptable than the clinician-administered test, but there was a lack of confidence that the test had been done correctly. Significant demographic differences in attitudes were found, with married women having more favourable attitudes towards self-sampling than single women, and Asian women having more negative attitudes than women in other ethnic groups. Intention to use self-sampling in the future was very high across all demographic groups. Self-sampling for HPV testing was highly acceptable in this large and demographically diverse sample, and women were able to carry out the test alone, using simple written instructions. Consistent with previous studies, women were concerned about doing the test properly and this issue will need to be addressed if self-sampling is introduced. More work is needed to see whether the demographic differences we found are robust and to identify reasons for lower acceptability among single women and those from Asian background.

  19. Use of a recombinant burkholderia intracellular motility a protein for immunodiagnosis of glanders.

    PubMed

    Kumar, Subodh; Malik, Praveen; Verma, Shailendra Kumar; Pal, Vijai; Gautam, Vandana; Mukhopadhyay, Chiranjay; Rai, Ganga Prasad

    2011-09-01

    Glanders, caused by the Gram-negative, nonmotile bacterium Burkholderia mallei, is a contagious and highly fatal disease of equines. During the last decade, the number of glanders outbreaks has increased steadily. The disease also has high zoonotic significance and B. mallei is listed biological warfare agent. The complement fixation test (CFT) is a routinely used and internationally recognized test to screen equine sera for the glanders. However, discrepant results have been observed using the CFT. The low sensitivity and specificity of the CFT and enzyme-linked immunosorbent assay (ELISA) have been linked to the use of crude test antigens. We expressed a novel recombinant Burkholderia intracellular motility A (rBimA) protein in Escherichia coli for the diagnosis of equine glanders. Purified rBimA was used in an indirect ELISA format. All of the 21 true-positive serum samples used in the study tested positive, whereas only 17 of the 1,524 potentially negative sera tested positive by indirect ELISA, thus exhibiting 100% sensitivity and 98.88% specificity. Also, rBimA protein did not react with melioidosis patient and normal healthy human serum samples, showing its high specificity. The developed assay can be used as a simple and rapid tool for diagnosis of glanders in equine serum samples. An Indian patent (1328/DEL/2010) has been filed for the reagent.

  20. Concordance of polymerase chain reaction with human immunodeficiency virus antibody detection.

    PubMed

    Horsburgh, C R; Ou, C Y; Jason, J; Holmberg, S D; Lifson, A R; Moore, J L; Ward, J W; Seage, G R; Mayer, K H; Evatt, B L

    1990-08-01

    To evaluate the correlation of detection of human immunodeficiency virus (HIV) by polymerase chain reaction (PCR) with detection of HIV antibody, 271 simultaneous serum and peripheral blood mononuclear cell samples were examined from 242 persons whose activities placed them at increased risk for HIV infection: 142 from homosexual men, 86 from hemophilic men, and 43 from heterosexual partners of HIV-infected persons. PCR was performed using the gag region primer pair SK38/39 and the env region primer pairs SK68/69 and CO71/72. Amplified HIV DNA was detected using specific oligomer probes. Of 63 HIV antibody-positive samples, 58 (92%) had HIV DNA by PCR. Of 208 HIV antibody-negative samples, 7 (3.4%) had HIV DNA by PCR. On follow-up, 4 of the latter persons were seropositive when next tested; 2 were well and antibody- and PCR-negative; 1 had died of a stroke before retesting. Thus, PCR detects HIV in most antibody-positive persons; detection is increased by use of multiple primer pairs. PCR-positive antibody-negative specimens may indicate HIV infection in which antibody has not yet developed or may be false-positive PCR results. When PCR is discordant with HIV antibody, testing of additional specimens and clinical follow-up are necessary to assess HIV infection status.

  1. Evaluation of microtiter-plate enzyme-linked immunosorbent assay for the analysis of triazine and chloroacetanilide herbicides in rainfall

    USGS Publications Warehouse

    Pomes, M.L.; Thurman, E.M.; Aga, D.S.; Goolsby, D.A.

    1998-01-01

    Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false- positive rate of 11.8% and the chloroacetanilide ELISA yielded a false- negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false-positive rate of 11.8% and the chloroacetanilide ELISA yielded a false-negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.

  2. Negative index effects from a homogeneous positive index prism

    NASA Astrophysics Data System (ADS)

    Marcus, Sherman W.; Epstein, Ariel

    2017-12-01

    Cellular structured negative index metamaterials in the form of a right triangular prism have often been tested by observing the refraction of a beam across the prism hypotenuse which is serrated in order to conform to the cell walls. We show that not only can this negative index effect be obtained from a homogeneous dielectric prism having a positive index of refraction, but in addition, for sampling at the walls of the cellular structure, the phase in the material has the illusory appearance of moving in a negative direction. Although many previous reports relied on refraction direction and phase velocity of prism structures to verify negative index design, our investigation indicates that to unambiguously demonstrate material negativity additional empirical evidence is required.

  3. Can human papillomavirus DNA testing of self-collected vaginal samples compare with physician-collected cervical samples and cytology for cervical cancer screening in developing countries?

    PubMed Central

    Bhatla, Neerja; Dar, Lalit; Patro, A. Rajkumar; Kumar, Pankaj; Kriplani, Alka; Gulati, Arti; Iyer, Venkateswaran K.; Mathur, Sandeep R.; Sreenivas, Vishnubhatla; Shah, Keerti V.; Gravitt, Patti E.

    2013-01-01

    Background To determine human papillomavirus (HPV) types by polymerase chain reaction (PCR)-reverse line blot assay and examine the concordance between HPV by Hybrid Capture 2 (HC2) and PCR on self-collected vaginal and physician-collected cervical samples and cytology. Methods This was a cross-sectional study of 546 sexually active women aged ≥30 years with persistent vaginal discharge, intermenstrual or postcoital bleeding or an unhealthy cervix. Participants self-collected vaginal samples (HPV-S) and physicians collected cervical samples for conventional Pap smear and HPV DNA (HPV-P) testing and performed colposcopy, with directed biopsy, if indicated. HPV testing and genotyping was done by HC2 and PCR reverse line blot assay. Concordance between HC2 and PCR results of self- and physician-collected samples was determined using a Kappa statistic (κ) and Chi-square test. Results Complete data were available for 512 sets with 98% of women providing a satisfactory self-sample. PCR detected oncogenic HPV in 12.3% of self- and 13.0% of physician-collected samples. Overall, there was 93.8% agreement between physician-collected and self-samples (κ = 76.31%, 95% confidence interval [CI]: 64.97–82.29%, p = 0.04)—complete concordance in 473 cases (57 positive, 416 negative), partial concordance in seven pairs and discordance in 32 pairs. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of self-sampling for detection of cervical intraepithelial neoplasia (CIN)2+ disease were 82.5%, 93.6%, 52.4% and 98.4%, respectively; for physician-sampling they were 87.5%, 93.2%, 52.2% and 98.9%, respectively; and for cytology they were 77.5%, 87.3%, 34.1% and 97.9%, respectively. Concordance between HC2 and PCR was 90.9% for self-samples (κ = 63.7%, 95% CI: 55.2–72.2%) and 95.3% for physician-collected samples (κ = 80.4%, 95% CI: 71.8–89.0%). Conclusions Self-HPV sampling compares favourably with physician-sampling and cytology. A rapid, affordable, HPV self-test kit can be used as the primary method of cervical cancer screening in low-resource situations. PMID:19931499

  4. Evaluation of the hyplex® TBC PCR test for detection of Mycobacterium tuberculosis complex in clinical samples

    PubMed Central

    2010-01-01

    Background Tuberculosis (TB) is one of the major public health concerns worldwide. The detection of the pathogen Mycobacterium tuberculosis complex (MTBC) as early as possible has a great impact on the effective control of the spread of the disease. In our study, we evaluated the hyplex® TBC PCR test (BAG Health Care GmbH), a novel assay using a nucleic acid amplification technique (NAAT) with reverse hybridisation and ELISA read out for the rapid detection of M. tuberculosis directly in clinical samples. Results A total of 581 respiratory and non-respiratory specimens from our pneumological hospital and the National TB Institute of Uzbekistan were used for the evaluation of the PCR assay. Of these, 292 were classified as TB samples and 289 as non-TB samples based on the results of the TB cultures as reference method. The PCR results were initially used to optimise the cut-off value of the hyplex® TBC test system by means of a ROC analysis. The overall sensitivity of the assay was determined to be 83.1%. In smear-positive TB samples, the sensitivity of the hyplex® TBC PCR test was estimated to 93.4% versus 45.1% in smear-negative samples. The specificity of the test was 99.25%. Of the two specimens (0.75%) with false-positive PCR results, one yielded a culture positive for non-tuberculous mycobacteria. Based on the assumption of a prevalence of 8% TB positives among the samples in our diagnostic TB laboratory, the positive and negative predictive values were estimated to 90.4% and 98.5%, respectively. Conclusions The hyplex® TBC PCR test is an accurate NAAT assay for a rapid and reliable detection of M. tuberculosis in various respiratory and non-respiratory specimens. Compared to many other conventional NAAT assays, the hyplex® TBC PCR test is in a low price segment which makes it an attractive option for developing and emerging countries with high TB burdens. PMID:20356361

  5. The uriscreen test to detect significant asymptomatic bacteriuria during pregnancy.

    PubMed

    Teppa, Roberto J; Roberts, James M

    2005-01-01

    Asymptomatic bacteriuria (ASB) occurs in 2-11% of pregnancies and it is a clear predisposition to the development of acute pyelonephritis, which, in turn, poses risk to mother and fetus. Treatment of bacteriuria during pregnancy reduces the incidence of pyelonephritis. Therefore, it is recommended to screen for ASB at the first prenatal visit. The gold standard for detection of bacteriuria during pregnancy is urine culture, but this test is expensive, time-consuming, and labor-intensive. To determine the reliability of an enzymatic urine screening test (Uriscreen; Savyon Diagnostics, Ashdod, Israel) for detecting ASB in pregnancy. Catheterized urine samples were collected from 150 women who had routine prenatal screening for ASB. Patients with urinary symptoms, active vaginal bleeding, or who were previously on antibiotics therapy were excluded from the study. Sensitivity, specificity, and the positive and negative predictive values for the Uriscreen were estimated using urine culture as the criterion standard. Urine cultures were considered positive if they grew >10(5) colony-forming units of a single uropathogen. Twenty-eight women (18.7%) had urine culture results indicating significant bacteriuria, and 17 of these 28 specimens had positive enzyme activity. Of 122 samples with no growth, 109 had negative enzyme activity. Sensitivity, specificity, and positive and negative predictive values for the Uriscreen test were 60.7% (+/-18.1), 89.3% (+/-5.6), 56.6%, and 90.8%, respectively. The Uriscreen test had inadequate sensitivity for rapid screening of bacteriuria in pregnancy.

  6. Are core self-evaluations a suitable moderator in stressor-detachment relationships? A study among managers' perceived job demands, detachment and strain reactions.

    PubMed

    Hentrich, Stephan; Zimber, Andreas; Sosnowsky-Waschek, Nadia; Gregersen, Sabine; Petermann, Franz

    2018-01-01

    The relationships among job demands, personality factors, recovery and psychological health receive increasing attention but are not well understoodOBJECTIVE:Therefore, the present study tests moderating effects among a sample of managers as proposed by the stressor-detachment model. We aimed to determine whether core self-evaluations (CSE) had an influence on the correlations between detachment and strain reactions (depressive symptoms, irritation, exhaustion) and between job demands and detachment. Further, we tested whether detachment attenuates the positive relation between job demands and strain reactions. A convenience sample of managers in three German settings (N = 282) participated in the cross-sectional study. Results based on hierarchical regression analysis showed that high CSE significantly weakened the negative relationship between detachment and depressive symptoms in this sample. However, CSE did not moderate the negative relationship between job demands and detachment. Moreover, results revealed that detachment moderated the positive relation between job demands and exhaustion. The authors tested whether CSE was able to moderate the relationship between job demands, psychological detachment and different stress reactions. Although we found a significant interaction effect, CSE may be too distal to moderate all respective associations.

  7. Evaluation and Validation of a Real-Time PCR Assay for Detection and Quantitation of Human Adenovirus 14 from Clinical Samples

    DTIC Science & Technology

    2009-09-01

    Legionella Pneumophila (ATCC 33152) were acquired from the American Type Culture Collection (ATCC; Manassas, VA, USA). Conventional PCR testing The primers... Legionella Pneumophila – One nanogram of genomic DNA was used as a DNA template in each assay. Assays were performed in triplicate. Samples were negative at

  8. E. coli and water quality: Reevaluation of mug tests and development of radical new indole test. Final technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, G.W.

    1992-12-01

    The project was undertaken to address the problem of MUG (4-methylumbelliferyl-B-D-glucuronide)-negative E. coli in water testing, and to develop a new, more reliable indole-based test for E. coli. In a study involving 39 healthy human volunteers, it was found that 1/3 of E. coli isolated from fresh human fecal samples tested MUG-negative in lauryl tryptose broth with MUG. It was further discovered: (1) The presence of simple sugars can cause catabolite repression of beta-GUR in a small percentage of E coli. (2) In gene probe studies, almost all E. coli isolates have portions of the uidA (GUR) gene sequence. Basedmore » on these two findings, catabolite repression can only be a partial explanation for the high-rate of GUR-negative E. coli. The authors improved the E. coli confirmatory medium, EC + MUG by removing the lactose, which allows for a stronger MUG test and the inclusion of the more reliable indole test. They called this newly improved medium INDEC, for Indole and EC medium. They later developed Colitag 3, a one-day, single tube indole-based test for E. coli.« less

  9. Evaluation of a Turbidimetric β-d-Glucan Test for Detection of Pneumocystis jirovecii Pneumonia.

    PubMed

    Dichtl, Karl; Seybold, Ulrich; Wagener, Johannes

    2018-07-01

    Currently, diagnosis of Pneumocystis jirovecii pneumonia (PJP) relies on analysis of lower respiratory specimens, either by microscopy or quantitative real-time PCR (qPCR). Thus, bronchoscopy is required, which is associated with increased risk of respiratory failure. We assessed the value of noninvasive serologic β-d-glucan (BDG) testing for laboratory diagnosis of PJP using a newly available turbidimetric assay. We identified 73 cases of PJP with positive qPCR results from lower respiratory specimens for Pneumocystis and serology samples dating from 1 week before to 4 weeks after qPCR. In addition, 25 sera from controls with suspected PJP but specimens negative for Pneumocystis by qPCR were identified. Sera were tested with a turbidimetric BDG assay (Fujifilm Wako Chemicals Europe GmbH, Neuss, Germany), using an 11-pg/ml cutoff. Sensitivity and specificity were calculated based on qPCR test results as a reference. The turbidimetric BDG assay identified 63/73 patients with positive or slightly positive qPCR tests for an overall sensitivity of 86%; after exclusion of cases with only slightly positive qPCR results, sensitivity was 91%. No correlation between serum BDG levels and respiratory specimen DNA levels was found. Serologic BDG testing was negative in 25/25 controls with negative qPCR for a specificity of 100% using the predefined cutoff. In 22/25 samples (88%), no BDG was detected. Serologic BDG testing using the turbidimetric assay showed high sensitivity and specificity compared to qPCR of lower respiratory specimens for the diagnosis of PJP. Both turnover time and test performance will allow clinicians to delay or in some cases forego bronchoscopy. Copyright © 2018 American Society for Microbiology.

  10. Testing predictive models of positive and negative affect with psychosocial, acculturation, and coping variables in a multiethnic undergraduate sample.

    PubMed

    Kuo, Ben Ch; Kwantes, Catherine T

    2014-01-01

    Despite the prevalence and popularity of research on positive and negative affect within the field of psychology, there is currently little research on affect involving the examination of cultural variables and with participants of diverse cultural and ethnic backgrounds. To the authors' knowledge, currently no empirical studies have comprehensively examined predictive models of positive and negative affect based specifically on multiple psychosocial, acculturation, and coping variables as predictors with any sample populations. Therefore, the purpose of the present study was to test the predictive power of perceived stress, social support, bidirectional acculturation (i.e., Canadian acculturation and heritage acculturation), religious coping and cultural coping (i.e., collective, avoidance, and engagement coping) in explaining positive and negative affect in a multiethnic sample of 301 undergraduate students in Canada. Two hierarchal multiple regressions were conducted, one for each affect as the dependent variable, with the above described predictors. The results supported the hypotheses and showed the two overall models to be significant in predicting affect of both kinds. Specifically, a higher level of positive affect was predicted by a lower level of perceived stress, less use of religious coping, and more use of engagement coping in dealing with stress by the participants. Higher level of negative affect, however, was predicted by a higher level of perceived stress and more use of avoidance coping in responding to stress. The current findings highlight the value and relevance of empirically examining the stress-coping-adaptation experiences of diverse populations from an affective conceptual framework, particularly with the inclusion of positive affect. Implications and recommendations for advancing future research and theoretical works in this area are considered and presented.

  11. A randomized controlled trial of ethyl glucuronide-based contingency management for outpatients with co-occurring alcohol use disorders and serious mental illness

    PubMed Central

    McDonell, Michael G.; Leickly, Emily; McPherson, Sterling; Skalisky, Jordan; Srebnik, Debra; Angelo, Frank; Vilardaga, Roger; Nepom, Jenny R.; Roll, John M.; Ries, Richard K.

    2017-01-01

    Objective To determine if a contingency management intervention using the ethyl glucuronide (EtG) alcohol biomarker resulted in increased alcohol abstinence in outpatients with co-occurring serious mental illnesses. Secondary objectives were to determine if contingency management was associated with changes in heavy drinking, treatment attendance, drug use, cigarette smoking, psychiatric symptoms, and HIV-risk behavior. Method Seventy-nine (37% female, 44% non-white) outpatients with serious mental illness and alcohol dependence receiving treatment as usual completed a 4-week observation period and were randomized to 12-weeks of contingency management for EtG-negative urine samples and addiction treatment attendance, or reinforcement only for study participation. Contingency management included the variable magnitude of reinforcement “prize draw” procedure contingent on EtG-negative samples (<150 ng/mL) three times a week and weekly gift cards for outpatient treatment attendance. Urine EtG, drug test, and self-report outcomes were assessed during the 12-week intervention and 3-month follow-up periods. Results Contingency management participants were 3.1 times (95% CI: 2.2, 4.5) more likely to submit an EtG-negative urine test during the 12-week intervention period, attaining nearly 1.5 weeks of additional abstinence relative to controls. Contingency management participants had significantly lower mean EtG levels, reported less drinking and fewer heavy drinking episodes, and were more likely to submit stimulant-negative urine and smoking-negative breath samples, relative to controls. Differences in self-reported alcohol use were maintained at the 3-month follow-up. Conclusions This is the first randomized trial utilizing an accurate and validated biomarker (EtG) to demonstrate the efficacy of contingency management for alcohol dependence in outpatients with serious mental illness. PMID:28135843

  12. A Randomized Controlled Trial of Ethyl Glucuronide-Based Contingency Management for Outpatients With Co-Occurring Alcohol Use Disorders and Serious Mental Illness.

    PubMed

    McDonell, Michael G; Leickly, Emily; McPherson, Sterling; Skalisky, Jordan; Srebnik, Debra; Angelo, Frank; Vilardaga, Roger; Nepom, Jenny R; Roll, John M; Ries, Richard K

    2017-04-01

    The authors examined whether a contingency management intervention using the ethyl glucuronide (EtG) alcohol biomarker resulted in increased alcohol abstinence in outpatients with co-occurring serious mental illnesses. Secondary objectives were to determine whether contingency management was associated with changes in heavy drinking, treatment attendance, drug use, cigarette smoking, psychiatric symptoms, and HIV-risk behavior. Seventy-nine (37% female, 44% nonwhite) outpatients with serious mental illness and alcohol dependence receiving treatment as usual completed a 4-week observation period and were randomly assigned to 12 weeks of contingency management for EtG-negative urine samples and addiction treatment attendance, or reinforcement only for study participation. Contingency management included the variable magnitude of reinforcement "prize draw" procedure contingent on EtG-negative samples (<150 ng/mL) three times a week and weekly gift cards for outpatient treatment attendance. Urine EtG, drug test, and self-report outcomes were assessed during the 12-week intervention and 3-month follow-up periods. Contingency management participants were 3.1 times (95% CI=2.2-4.5) more likely to submit an EtG-negative urine test during the 12-week intervention period, attaining nearly 1.5 weeks of additional alcohol abstinence compared with controls. Contingency management participants had significantly lower mean EtG levels, reported less drinking and fewer heavy drinking episodes, and were more likely to submit stimulant-negative urine and smoking-negative breath samples, compared with controls. Differences in self-reported alcohol use were maintained at the 3-month follow-up. This is the first randomized trial utilizing an accurate and validated biomarker (EtG) to demonstrate the efficacy of contingency management for alcohol dependence in outpatients with serious mental illness.

  13. Rapid diagnosis of cryptococcal meningitis by use of lateral flow assay on cerebrospinal fluid samples: influence of the high-dose "hook" effect.

    PubMed

    Lourens, Adré; Jarvis, Joseph N; Meintjes, Graeme; Samuel, Catherine M

    2014-12-01

    Cryptococcal meningitis is the most frequent cause of meningitis and a major cause of mortality in HIV-infected adults in Africa. This study evaluated the performance of the lateral flow assay (LFA) on cerebrospinal fluid (CSF) samples for the diagnosis of cryptococcal meningitis against that of existing diagnostic tests. LFA performed on 465 undiluted CSF samples had a sensitivity of 91%. When the LFA was paired with Gram staining, a sensitivity of 100% was achieved after implementation of a dilution step for samples with negative LFA results and the presence of yeasts on microscopy. Microscopy is essential for preventing the reporting of false-negative results due to the high-dose "hook" effect. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  14. A clinical score to obviate the need for cardiac stress testing in patients with acute chest pain and negative troponins.

    PubMed

    Bouzas-Mosquera, Alberto; Peteiro, Jesús; Broullón, Francisco J; Álvarez-García, Nemesio; Maneiro-Melón, Nicolás; Pardo-Martinez, Patricia; Sagastagoitia-Fornie, Marta; Martínez, Dolores; Yáñez, Juan C; Vázquez-Rodríguez, José Manuel

    2016-08-01

    Although cardiac stress testing may help establish the safety of early discharge in patients with suspected acute coronary syndromes and negative troponins, more cost-effective strategies are necessary. We aimed to develop a clinical prediction rule to safely obviate the need for cardiac stress testing in this setting. A decision rule was derived in a prospective cohort of 3001 patients with acute chest pain and negative troponins, and validated in a set of 1473 subjects. The primary end point was a composite of positive cardiac stress testing (in the absence of a subsequent negative coronary angiogram), positive coronary angiography, or any major coronary events within 3 months. A score chart was built based on 7 variables: male sex (+2), age (+1 per decade from the fifth decade), diabetes mellitus (+2), hypercholesterolemia (+1), prior coronary revascularization (+2), type of chest pain (typical angina, +5; non-specific chest pain, -3), and non-diagnostic repolarization abnormalities (+2). In the validation set, the model showed good discrimination (c statistic = 0.84; 95% confidence interval, 0.82-0.87) and calibration (Hosmer-Lemeshow goodness-of-fit test, P= .34). If stress tests were avoided in patients in the validation sample with a sum score of 0 or lower, the number of referrals would be reduced by 23.4%, yielding a negative predictive value of 98.8% (95% confidence interval, 97.0%-99.7%). This novel prediction rule based on a combination of readily available clinical characteristics may be a valuable tool to decide whether stress testing can be reliably avoided in patients with acute chest pain and negative troponins. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Comparison of different commercial ELISAs for detection of antibodies against porcine respiratory and reproductive syndrome virus in serum.

    PubMed

    Sattler, Tatjana; Wodak, Eveline; Revilla-Fernández, Sandra; Schmoll, Friedrich

    2014-12-18

    In recent years, several new ELISAs for the detection of antibodies against the porcine reproductive and respiratory disease virus (PRRSV) in pig serum have been developed. To interpret the results, specificity and sensitivity data as well as agreement to a reference ELISA must be available. In this study, three commercial ELISAs (INgezim PRRS 2.0 - ELISA II, Priocheck® PRRSV Ab porcine - ELISA III and CIVTEST suis PRRS E/S PLUS - ELISA IV, detecting PRRSV type 1 antibodies) were compared to a standard ELISA (IDEXX PRRS X3 Ab Test - ELISA I). The serum of three pigs vaccinated with an attenuated PRRSV live vaccine (genotype 2) was tested prior to and several times after the vaccination. Furthermore, serum samples of 245 pigs of PRRSV positive herds, 309 pigs of monitored PRRSV negative herds, 256 fatteners of assumed PRRSV negative herds with unknown herd history and 92 wild boars were tested with all four ELISAs. ELISAs II and III were able to detect seroconversion of vaccinated pigs with a similar reliability. According to kappa coefficient, the results showed an almost perfect agreement between ELISA I as reference and ELISA II and III (kappa > 0.8), and substantial agreement between ELISA I and ELISA IV (kappa = 0.71). Sensitivity of ELISA II, III and IV was 96.0%, 100% and 91.5%, respectively. The specificity of the ELISAs determined in samples of monitored PRRSV negative herds was 99.0%, 95.1% and 96.4%, respectively. In assumed negative farms that were not continually monitored, more positive samples were found with ELISA II to IV. The reference ELISA I had a specificity of 100% in this study. All tested ELISAs were able to detect a PRRSV positive herd. The specificity and sensitivity of the tested commercial ELISAs, however, differed. ELISA II had the highest specificity and ELISA III had the highest sensitivity in comparison to the reference ELISA. ELISA IV had a lower sensitivity and specificity than the other ELISAs.

  16. Evaluation of the Efficacy, Potential for Vector Transmission, and Duration of Immunity of MP-12, an Attenuated Rift Valley Fever Virus Vaccine Candidate, in Sheep

    DTIC Science & Technology

    2015-08-01

    testing by virus isolation (VI). Positive-control mosquitoes were sampled whole on the day of the spiked blood meal. b NA, not applicable. Miller et al ...percent inhibition of the negative control, calculated as 1 (test serum OD/negative serum OD) 100. Miller et al . 934 cvi.asm.org August 2015 Volume 22...Trop Med Hyg 44:278 –282. 34. Morrill JC, Mebus CA, Peters CJ. 1997. Safety of a mutagen-attenuated Miller et al . 936 cvi.asm.org August 2015 Volume 22

  17. An assessment of false positive rates for malaria rapid diagnostic tests caused by non-Plasmodium infectious agents and immunological factors.

    PubMed

    Gatton, Michelle L; Ciketic, Sadmir; Barnwell, John W; Cheng, Qin; Chiodini, Peter L; Incardona, Sandra; Bell, David; Cunningham, Jane; González, Iveth J

    2018-01-01

    Malaria rapid diagnostic tests (RDTs) can produce false positive (FP) results in patients with human African trypanosomiasis and rheumatoid factor (RF), but specificity against other infectious agents and immunological factors is largely unknown. Low diagnostic specificity caused by cross-reactivity may lead to over-estimates of the number of malaria cases and over-use of antimalarial drugs, at the cost of not diagnosing and treating the true underlying condition. Data from the WHO Malaria RDT Product Testing Programme was analysed to assess FP rates of 221 RDTs against four infectious agents (Chagas, dengue, Leishmaniasis and Schistosomiasis) and four immunological factors (anti-nuclear antibody, human anti-mouse antibody (HAMA), RF and rapid plasma regain). Only RDTs with a FP rate against clean negative samples less than 10% were included. Paired t-tests were used to compare product-specific FP rates on clean negative samples and samples containing non-Plasmodium infectious agents and immunological factors. Forty (18%) RDTs showed no FP results against any tested infectious agent or immunological factor. In the remaining RDTs significant and clinically relevant increases in FP rates were observed for samples containing HAMA and RF (P<0.001). There were significant correlations between product-matched FP rates for RF and HAMA on all RDT test bands (P<0.001), and FP rates for each infectious agent and immunological factor were also correlated between test bands of combination RDTs (P≤0.002). False positive results against non-Plasmodium infectious agents and immunological factors does not appear to be a universal property of malaria RDTs. However, since many malaria RDTs have elevated FP rates against HAMA and RF positive samples practitioners may need to consider the possibility of false positive results for malaria in patients with conditions that stimulate HAMA or RF.

  18. Prevalence of Candidatus Mycoplasma haemolamae, bovine viral diarrhoea virus, and gastrointestinal parasitism in a sample of adult New Zealand alpaca (Vicugna pacos).

    PubMed

    Dittmer, K E; Hinkson, J A; Dwyer, C; Adlington, B; van Andel, M

    2018-01-01

    To determine the prevalence of infection with Candidatus Mycoplasma haemolamae (Mhl), antibodies to bovine viral diarrhoea virus (BVDV), and BVDV antigen, and the prevalence of animals with elevated faecal nematode egg counts (FEC) in a sample of adult New Zealand alpaca (Vicugna pacos). Blood samples were obtained from 175 alpaca, collected from 15 farms around New Zealand, and from 31 samples sent to a diagnostic laboratory for routine haematology. Blood smears (n=170) were examined microscopically for the presence of haemoplasma, and DNA was extracted from whole blood (n=206) for real-time PCR testing for Mhl. Packed cell volume (PCV) was determined for 193 samples. Serum samples (n=195) were tested for BVDV antibody using ELISA, and for BVDV antigen using a real-time PCR assay. Faecal samples were collected from 143 animals; FEC were measured, and samples pooled for larval culture. No haemoplasma organisms were present on blood smear examination. Of the 206 blood samples, two (from the same farm) were positive for Mhl by real-time PCR testing, giving a prevalence of infection with Mhl of 0.97%. Of the 195 serum samples tested, four (2.1%) were positive for antibodies to BVDV; animals with BVDV antibodies were from 3/15 (20%) farms, none of which farmed cattle. None of the serum samples were positive by PCR for BVDV antigen. The median FEC was 50 epg (min 0, max 4,700), with 55/143 (38.5%) samples having 0 epg, and 33/143 (23.1%) having ≥250 epg. Haemonchus spp. were the most common nematodes present in faecal larval cultures from the North Island. Log 10 FEC was negatively associated with PCV (p=0.02), and was higher in males than females (p<0.001), and in animals that were positive compared with negative for Mhl (p=0.022). The number of alpaca infected with Mhl was low, as was the seroprevalence of BVDV. Gastrointestinal parasitism was, however, a common finding in this sample of New Zealand alpaca.

  19. Comparison between two widely used laboratory methods in BRAF V600 mutation detection in a large cohort of clinical samples of cutaneous melanoma metastases to the lymph nodes.

    PubMed

    Jurkowska, Monika; Gos, Aleksandra; Ptaszyński, Konrad; Michej, Wanda; Tysarowski, Andrzej; Zub, Renata; Siedlecki, Janusz A; Rutkowski, Piotr

    2015-01-01

    The study compares detection rates of oncogenic BRAF mutations in a homogenous group of 236 FFPE cutaneous melanoma lymph node metastases, collected in one cancer center. BRAF mutational status was verified by two independent in-house PCR/Sanger sequencing tests, and the Cobas® 4800 BRAF V600 Mutation Test. The best of two sequencing approaches returned results for 230/236 samples. In 140 (60.9%), the mutation in codon 600 of BRAF was found. 91.4% of all mutated cases (128 samples) represented p.V600E. Both Sanger-based tests gave reproducible results although they differed significantly in the percentage of amplifiable samples: 230/236 to 109/143. Cobas generated results in all 236 cases, mutations changing codon V600 were detected in 144 of them (61.0%), including 5 not amplifiable and 5 negative in the standard sequencing. However, 6 cases positive in sequencing turned out to be negative in Cobas. Both tests provided us with the same BRAF V600 mutational status in 219 out of 230 cases with valid results (95.2%). The total BRAF V600 mutation detection rate didn't differ significantly between the two methodological approaches (60.9% vs. 61.0%). Sequencing was a reproducible method of V600 mutation detection and more powerful to detect mutations other than p.V600E, while Cobas test proved to be less susceptible to the poor DNA quality or investigator's bias. The study underlined an important role of pathologists in quality assurance of molecular diagnostics.

  20. Prevalence and bacterial etiology of subclinical mastitis in goats reared in organized farms

    PubMed Central

    Mishra, A. K.; Sharma, Nitika; Singh, D. D.; Gururaj, K.; Abhishek; Kumar, Vijay; Sharma, D. K.

    2018-01-01

    Aim: Assessment of the status of subclinical mastitis (SCM) in Jamunapari and Barbari goats in Indian organized farms, the involvement of bacterial pathogens and their sensitivity to antibiotics. Materials and Methods: A total of 181 composite milk samples were aseptically collected from the apparently healthy Barbari (n=95) and Jamunapari (n=86) goats. The California mastitis test (CMT) and somatic cell count (SCC) were used to diagnose SCM. The milk samples with CMT scores of 0 and +1 were considered as negative, while the samples with the score of +2 or +3 were taken as positive, and further, the positive samples were used for the bacteriological examination. An antibiotic sensitivity test was performed by disk diffusion method using seven commercially available antibiotic discs. Results: All the samples having CMT score of +2 or +3 demonstrated SCC more than 1 million. Overall, the prevalence of SCM in the goats was assessed as 19.89% (36/181). The prevalence of SCM in Barbari and Jamunapari goats was found as 24.21% (23/95) and 15.12% (13/86), respectively. Out of 11 isolates of Staphylococci, 9 isolates were identified as coagulase-negative Staphylococci (CNS), whereas 2 isolates were found as Staphylococcus aureus. The identified bacterial isolates (n=30) did not show antibiotic resistance. Conclusion: The current investigation showed the considerable prevalence of SCM among Jamunapari and Barbari goats which may have a negative impact on quantity and quality of the milk. CNS was found as the most prevalent cause of SCM in the goats. Negligible antibiotic resistance was found among the identified udder pathogens. PMID:29479152

  1. Tube and column agglutination technology for autocontrol testing.

    PubMed

    Courtney, J E; Vincent, J L; Indrikovs, A J

    2001-01-01

    The incidence of positive autocontrol test results with column agglutination technology is a concern. This study investigates the incidence and significance of positive autocontrols in the ID Micro Typing System (gel) and the Gamma ReACT (ReACT). The study encompassed a total of 1021 randomly selected samples from patients and 95 samples from donors collected during 1 month. The autocontrol testing was carried out according to the manufacturer's instructions for the column agglutination tests. The tube method was carried out using low-ionic-strength solution (LISS). The direct antiglobulin test (DAT) was performed using the tube method, and further investigated with elution studies if warranted. Seventy-nine patient's samples (7.74%) had a positive autocontrol: the gel test, 72 (91.13%); ReACT, 21 (26.58%); and the tube method, 27 (34.18%). Of the 79 positive autocontrols, 44 samples had a negative DAT. Of the samples with positive DAT results, only one possessed a clinically significant antibody, anti-D. Moreover, the same sample also tested positive in all three methods. Column agglutination techniques have increased sensitivity for a positive autocontrol beyond the conventional tube method. However, ReACT and gel tests differ significantly in their frequency of positives. Investigation of the significance of a positive autocontrol in column agglutination technology when the conventional tube method is also positive is suggested.

  2. [Laboratory diagnosis of auto-immune hemolytic anemia: characteristics of the manual direct test of Polybrene].

    PubMed

    Braga, G W; Bordin, J O; Moreira Júnior, G; Kuroda, A

    1998-01-01

    The direct manual Polybrene test (DPT) and the direct antiglobulin tests (DAT) were employed to detect antibody sensitizing red blood cell (RCB) in patients with clinical and laboratorial findings of autoimmune hemolytic anemia (AIHA). To compare the sensitivity and specificity of DPT and DAT in the diagnosis of AIHA. Eighteen consecutive patients with diagnosis of AIHA were evaluated. The control group consisted of 20 normal volunteers blood donors and 20 patients with sickle cell anemia. All patients and controls were submitted to DPT and DAT. All DAT positive samples were further tested using monospecific reagents (anti-IgG heavy chain and anti-C3d). Positive samples for either DPT or DAT were evaluated by eluate technique using. The dichloromethane (DCM). The DAT was positive in 14 patients and negative in 4 subjects, while the DPT was positive in 17 patients and negative in 1 individual who had a positive DAT owing to complement (C3d). All positive eluates performed with DCM showed RBC autoantibodies with presumed "anti-Rh" specificity. The sensitivity rate of the DPT (94%) was significantly (p < 0.05) higher than the sensitivity rate of DAT (78%) to determine whether IgG was bound in vivo, but no difference was found regarding the specificity of the two tests. 1) The DPT is more sensitive than the DAT in detecting IgG autoantibody on the RBCs of patients with AIHA; 2) because of its simplicity and rapidity, the DPT is a useful additional screening test for the investigation of Coombs-negative AIHA.

  3. Escherichia coli O104 in Feedlot Cattle Feces: Prevalence, Isolation and Characterization.

    PubMed

    Shridhar, Pragathi B; Noll, Lance W; Shi, Xiaorong; Cernicchiaro, Natalia; Renter, David G; Bai, J; Nagaraja, T G

    2016-01-01

    Escherichia coli O104:H4, an hybrid pathotype of Shiga toxigenic and enteroaggregative E. coli, involved in a major foodborne outbreak in Germany in 2011, has not been detected in cattle feces. Serogroup O104 with H type other than H4 has been reported to cause human illnesses, but their prevalence and characteristics in cattle have not been reported. Our objectives were to determine the prevalence of E. coli O104 in feces of feedlot cattle, by culture and PCR detection methods, and characterize the isolated strains. Rectal fecal samples from a total of 757 cattle originating from 29 feedlots were collected at a Midwest commercial slaughter plant. Fecal samples, enriched in E. coli broth, were subjected to culture and PCR methods of detection. The culture method involved immunomagnetic separation with O104-specific beads and plating on a selective chromogenic medium, followed by serogroup confirmation of pooled colonies by PCR. If pooled colonies were positive for the wzxO104 gene, then colonies were tested individually to identify wzxO104-positive serogroup and associated genes of the hybrid strains. Extracted DNA from feces were also tested by a multiplex PCR to detect wzxO104-positive serogroup and associated major genes of the O104 hybrid pathotype. Because wzxO104 has been shown to be present in E. coli O8/O9/O9a, wzxO104-positive isolates and extracted DNA from fecal samples were also tested by a PCR targeting wbdDO8/O9/O9a, a gene specific for E. coli O8/O9/O9a serogroups. Model-adjusted prevalence estimates of E. coli O104 (positive for wzxO104 and negative for wbdDO8/O9/O9a) at the feedlot level were 5.7% and 21.2%, and at the sample level were 0.5% and 25.9% by culture and PCR, respectively. The McNemar's test indicated that there was a significant difference (P < 0.01) between the proportions of samples that tested positive for wzxO104 and samples that were positive for wzxO104, but negative for wbdDO8/O9/O9a by PCR and culture methods. A total of 143 isolates, positive for the wzxO104, were obtained in pure culture from 146 positive fecal samples. Ninety-two of the 143 isolates (64.3%) also tested positive for the wbdDO8/O9/O9a, indicating that only 51 (35.7%) isolates truly belonged to the O104 serogroup (positive for wzxO104 and negative for wbdDO8/O9/O9a). All 51 isolates tested negative for eae, and 16 tested positive for stx1 gene of the subtype 1c. Thirteen of the 16 stx1-positive O104 isolates were from one feedlot. The predominant serotype was O104:H7. Pulsed-field gel electrophoresis analysis indicated that stx1-positive O104:H7 isolates had 62.4% homology to the German outbreak strain and 67.9% to 77.5% homology to human diarrheagenic O104:H7 strains. The 13 isolates obtained from the same feedlot were of the same PFGE subtype with 100% Dice similarity. Although cattle do not harbor the O104:H4 pathotype, they do harbor and shed Shiga toxigenic O104 in the feces and the predominant serotype was O104:H7.

  4. Bayesian Integration and Classification of Composition C-4 Plastic Explosives Based on Time-of-Flight-Secondary Ion Mass Spectrometry and Laser Ablation-Inductively Coupled Plasma Mass Spectrometry.

    PubMed

    Mahoney, Christine M; Kelly, Ryan T; Alexander, Liz; Newburn, Matt; Bader, Sydney; Ewing, Robert G; Fahey, Albert J; Atkinson, David A; Beagley, Nathaniel

    2016-04-05

    Time-of-flight-secondary ion mass spectrometry (TOF-SIMS) and laser ablation-inductively coupled plasma mass spectrometry (LA-ICPMS) were used for characterization and identification of unique signatures from a series of 18 Composition C-4 plastic explosives. The samples were obtained from various commercial and military sources around the country. Positive and negative ion TOF-SIMS data were acquired directly from the C-4 residue on Si surfaces, where the positive ion mass spectra obtained were consistent with the major composition of organic additives, and the negative ion mass spectra were more consistent with explosive content in the C-4 samples. Each series of mass spectra was subjected to partial least squares-discriminant analysis (PLS-DA), a multivariate statistical analysis approach which serves to first find the areas of maximum variance within different classes of C-4 and subsequently to classify unknown samples based on correlations between the unknown data set and the original data set (often referred to as a training data set). This method was able to successfully classify test samples of C-4, though with a limited degree of certainty. The classification accuracy of the method was further improved by integrating the positive and negative ion data using a Bayesian approach. The TOF-SIMS data was combined with a second analytical method, LA-ICPMS, which was used to analyze elemental signatures in the C-4. The integrated data were able to classify test samples with a high degree of certainty. Results indicate that this Bayesian integrated approach constitutes a robust classification method that should be employable even in dirty samples collected in the field.

  5. Lack of evidence for the presence of emerging HoBi-like viruses in North American fetal bovine serum lots.

    PubMed

    Bauermann, Fernando V; Flores, Eduardo F; Falkenberg, Shollie M; Weiblen, Rudi; Ridpath, Julia F

    2014-01-01

    The detection of an emerging pestivirus species, "HoBi-like virus," in fetal bovine serum (FBS) labeled as U.S. origin, but packaged in Europe, raised concerns that HoBi-like virus may have entered the United States. In the current study, 90 lots of FBS originating in North America (NA) were screened for pestivirus antigen and antibodies. Lots in group 1 (G1, 72 samples) and group 2 (G2, 9 samples) originated in NA and were packaged in the United States. Group 3 (G3) was composed of 9 lots collected in NA and processed in Europe. Lots in G1 were claimed negative for Bovine viral diarrhea virus (BVDV), while lots in G2 and G3 were claimed positive by the commercial processor. All lots in G1 and G2 tested negative by reverse transcription polymerase chain reaction (RT-PCR) using HoBi-like-specific primers. Two G1 lots tested positive by BVDV RT-PCR. One of these was also positive by virus isolation. All G2 lots were positive by BVDV RT-PCR. In addition, four G2 lots were VI positive while 1 lot was antigen-capture enzyme-linked immunosorbent assay (ELISA) positive. Two G3 lots were positive by HoBi-like-specific RT-PCR tests. All lots were negative for HoBi_D32/00 neutralizing antibodies. Seven lots (4 G1; 1 G2; 2 G3) had antibodies against BVDV by virus neutralization and/or antigen-capture ELISA. While there is no evidence of HoBi-like viruses in NA based on tested samples, further studies are required to validate HoBi-like virus-free status and develop means to prevent the spread of HoBi-like virus into NA.

  6. Accuracy of a Mouse Bioassay for the Diagnosis of Botulism in Horses.

    PubMed

    Johnson, A L; McAdams-Gallagher, S C; Aceto, H

    2016-07-01

    The laboratory diagnosis of botulism in horses traditionally has relied upon the mouse bioassay (MBA). The accuracy of this test for the diagnosis of botulism in horses is unknown. Our goal was to determine the sensitivity, specificity, positive predictive value, and negative predictive value of the MBA on laboratory-processed fecal and gastrointestinal samples for foals and adult horses. Cases included all horses with a final clinical diagnosis of botulism that were admitted between 1986 and 2011 and had MBA testing performed. Controls included horses without botulism that were admitted during the same time period and had MBA testing performed. Retrospective study. Horses suspected of having botulism had fecal or (less commonly) gastrointestinal content samples tested using MBA. For every hospitalized botulism suspect, control samples were obtained from ≥1 additional hospitalized horses not suspected to have botulism. One hundred and twenty-nine adult horses and 253 adult controls were identified. Overall sensitivity of the MBA was only 32% but specificity was 97%. Forty-three foal cases and 21 foal controls were evaluated; sensitivity of the MBA was 53% and specificity was 100%. Positive predictive value was substantially higher (100% for foals and 89% for adults) than negative predictive value (51% for foals and 67% for adults). Mouse bioassay has low sensitivity but high specificity for the diagnosis of botulism in horses. Positive results are highly suggestive of botulism but negative results do not exclude the diagnosis. Unaffected horses and foals rarely shed C. botulinum in their feces. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  7. A high-performance liquid chromatography method for the serotonin release assay is equivalent to the radioactive method.

    PubMed

    Sono-Koree, N K; Crist, R A; Frank, E L; Rodgers, G M; Smock, K J

    2016-02-01

    The serotonin release assay (SRA) is considered the gold standard laboratory test for heparin-induced thrombocytopenia (HIT). The historic SRA method uses platelets loaded with radiolabeled serotonin to evaluate platelet activation by HIT immune complexes. However, a nonradioactive method is desirable. We report the performance characteristics of a high-performance liquid chromatography (HPLC) SRA method. We validated the performance characteristics of an HPLC-SRA method, including correlation with a reference laboratory using the radioactive method. Serotonin released from reagent platelets was quantified by HPLC using fluorescent detection. Results were expressed as % release and classified as positive, negative, or indeterminate based on previously published cutoffs. Serum samples from 250 subjects with suspected HIT were tested in the HPLC-SRA and with the radioactive method. Concordant classifications were observed in 230 samples (92%). Sera from 41 healthy individuals tested negative. Between-run imprecision studies showed standard deviation of <6 (% release) for positive, weak positive, and negative serum pools. Stability studies demonstrated stability after two freeze-thaw cycles or up to a week of refrigeration. The HPLC-SRA has robust performance characteristics, equivalent to the historic radioactive method, but avoids the complexities of working with radioactivity. © 2015 John Wiley & Sons Ltd.

  8. Comparison of patient- and clinician-collected anal cytology samples to screen for human papillomavirus-associated anal intraepithelial neoplasia in men who have sex with men.

    PubMed

    Chin-Hong, Peter V; Berry, J Michael; Cheng, Su-Chun; Catania, Joseph A; Da Costa, Maria; Darragh, Teresa M; Fishman, Fred; Jay, Naomi; Pollack, Lance M; Palefsky, Joel M

    2008-09-02

    Human papillomavirus (HPV)-associated anal cancer is increasing in prevalence and is more common among men who have sex with men and HIV-positive individuals than cervical cancer is among women in the United States. Cytology screening can detect the anal cancer precursor, anal intraepithelial neoplasia (AIN). Little is known about self-collected samples for AIN screening, and few community-based AIN estimates exist. To compare the sensitivity of self-collected versus clinician-collected anal cytology specimens to detect biopsy-confirmed AIN and the prevalence estimate of AIN in a community sample. Cross-sectional study. Participants were mailed anal cytology self-collection kits with instructions. Clinicians repeated anal cytology and performed high-resolution anoscopy with biopsies as the diagnostic reference standard. San Francisco, California. Community-based sample of men who have sex with men. Prevalence of anal HPV and AIN. Sensitivity and specificity of self-collected and clinician-collected anal cytology specimens to diagnose AIN were calculated. Biopsy-proven AIN was diagnosed in 57% of HIV-positive and 35% of HIV-negative participants (P = 0.04), and 80% provided adequate self-collected specimens for interpretation. The sensitivity of cytology to detect AIN in HIV-positive men was 75% (95% CI, 51% to 93%) when self-collected and 90% (CI, 68% to 99%) when clinician-collected; respective values in HIV-negative men were 48% (CI, 26% to 70%) and 62% (CI, 38% to 82%). The specificity of cytology to detect AIN in HIV-positive men was 50% (CI, 22% to 78%) when self-collected and 64% (CI, 36% to 86%) when clinician-collected; respective values in HIV-negative men were 86% (CI, 71% to 94%) and 85% (CI, 72% to 93%). The study sample was from a narrowly defined geographical area. Participants self-reported HIV status. In a community-based sample, a high proportion of HIV-positive and HIV-negative men who have sex with men have AIN. The sensitivity of cytology to detect AIN is higher for clinician-collected versus self-collected specimens and for HIV-positive versus HIV-negative men. The specificity of cytology to detect AIN is higher in HIV-negative versus HIV-positive men. However, the probability of AIN in a patient with a negative cytology result may not be low enough (23% for HIV-negative men and 45% for HIV-positive men with a patient-collected specimen) for clinicians to be comfortable recommending no anoscopy for those with a negative cytology result if done as a one-time test. These data raise the question of whether the optimal population screening strategy is cytology screening with anoscopy only for those who test positive or whether anoscopy should be recommended for everyone in these risk groups. Given limited resources and the limited number of clinicians trained in anoscopy, cytology screening may be the best current approach to identifying disease in the at-risk population.

  9. The neural correlates of priming emotion and reward systems for conflict processing in alcoholics.

    PubMed

    Schulte, T; Jung, Y-C; Sullivan, E V; Pfefferbaum, A; Serventi, M; Müller-Oehring, E M

    2017-12-01

    Emotional dysregulation in alcoholism (ALC) may result from disturbed inhibitory mechanisms. We therefore tested emotion and alcohol cue reactivity and inhibitory processes using negative priming. To test the neural correlates of cue reactivity and negative priming, 26 ALC and 26 age-matched controls underwent functional MRI performing a Stroop color match-to-sample task. In cue reactivity trials, task-irrelevant emotion and alcohol-related pictures were interspersed between color samples and color words. In negative priming trials, pictures primed the semantic content of an alcohol or emotion Stroop word. Behaviorally, both groups showed response facilitation to picture cue trials and response inhibition to primed trials. For cue reactivity to emotion and alcohol pictures, ALC showed midbrain-limbic activation. By contrast, controls activated frontoparietal executive control regions. Greater midbrain-hippocampal activation in ALC correlated with higher amounts of lifetime alcohol consumption and higher anxiety. With negative priming, ALC exhibited frontal cortical but not midbrain-hippocampal activation, similar to the pattern observed in controls. Higher frontal activation to alcohol-priming correlated with less craving and to emotion-priming with fewer depressive symptoms. The findings suggest that neurofunctional systems in ALC can be primed to deal with upcoming emotion- and alcohol-related conflict and can overcome the prepotent midbrain-limbic cue reactivity response.

  10. Impact of grey zone sample testing by enzyme-linked immunosorbent assay in enhancing blood safety: Experience at a tertiary care hospital in North India.

    PubMed

    Solanki, Archana; Singh, Abhay; Chaudhary, Rajendra

    2016-01-01

    Enzyme-linked immunosorbent assay (ELISA) used for screening blood donors for transfusion transmitted infections (TTIs) can sometimes fail to detect blood donors who are recently infected or possessing the low strength of pathogen. Estimation of a grey zone in ELISA testing and repeat testing of grey zone samples can further help in reducing the risks of TTI in countries where nucleic acid amplification testing for TTIs is not feasible. Grey zone samples with optical density (OD) lying between cut-off OD and 10% below the cut-off OD (cut-off OD × 0.9) were identified during routine ELISA testing. On performing repeat ELISA testing on grey zone samples in duplicate, the samples showing both OD value below grey zone were marked nonreactive, and samples showing one or both OD value in the grey zone were marked indeterminate. The samples on repeat testing showing one or both OD above cut-off value were marked positive. About 119 samples (77 for hepatitis B virus [HBV], 23 for human immunodeficiency virus [HIV], and 19 for hepatitis C virus [HCV]) were found to be in grey zone. On repeat testing of these samples in duplicate, 70 (58.8%) samples (45 for HBV, 12 for HIV, and 13 for HCV) were found to be reactive. Six (5%) samples (four for HBV, one for HIV, and one for HCV) were found to be indeterminate. Seventy donors initially screened negative, were found out to be potentially infectious on repeat grey zone testing. Thus, estimation of grey zone samples with repeat testing can further enhance the safety of blood transfusion.

  11. A two-hypothesis approach to establishing a life detection/biohazard protocol for planetary samples

    NASA Astrophysics Data System (ADS)

    Conley, Catharine; Steele, Andrew

    2016-07-01

    The COSPAR policy on performing a biohazard assessment on samples brought from Mars to Earth is framed in the context of a concern for false-positive results. However, as noted during the 2012 Workshop for Life Detection in Samples from Mars (ref. Kminek et al., 2014), a more significant concern for planetary samples brought to Earth is false-negative results, because an undetected biohazard could increase risk to the Earth. This is the reason that stringent contamination control must be a high priority for all Category V Restricted Earth Return missions. A useful conceptual framework for addressing these concerns involves two complementary 'null' hypotheses: testing both of them, together, would allow statistical and community confidence to be developed regarding one or the other conclusion. As noted above, false negatives are of primary concern for safety of the Earth, so the 'Earth Safety null hypothesis' -- that must be disproved to assure low risk to the Earth from samples introduced by Category V Restricted Earth Return missions -- is 'There is native life in these samples.' False positives are of primary concern for Astrobiology, so the 'Astrobiology null hypothesis' -- that must be disproved in order to demonstrate the existence of extraterrestrial life is 'There is no life in these samples.' The presence of Earth contamination would render both of these hypotheses more difficult to disprove. Both these hypotheses can be tested following a strict science protocol; analyse, interprete, test the hypotheses and repeat. The science measurements undertaken are then done in an iterative fashion that responds to discovery with both hypotheses testable from interpretation of the scientific data. This is a robust, community involved activity that ensures maximum science return with minimal sample use.

  12. Negative Attitudes toward Older Workers and Hiring Decisions: Testing the Moderating Role of Decision Makers' Core Self-Evaluations.

    PubMed

    Fasbender, Ulrike; Wang, Mo

    2016-01-01

    Organizational hiring practices have been charged for unfair treatment on the grounds of age. Drawing on theories of planned behavior and core self-evaluations, this research investigated the impact of negative attitudes toward older workers on hiring decisions and examined the moderating role of decision-makers' core self-evaluations. We tested our hypotheses based on a structured online questionnaire and a vignette study using a sample of 102 participants working in human resource management across different industries. As predicted, negative attitudes toward older workers were positively related to avoidance of hiring older people, which in turn was negatively related to the likelihood to select the oldest candidate. Because hiring decisions are not only about the hiring subject but also about the decision-maker, we tested the moderating role of decision-makers' core self-evaluations. Results showed that core self-evaluations buffered the relationship between negative attitudes toward older workers and avoidance of hiring older people. Theoretical implications of the findings with regard to hiring decisions about older people and practical recommendations to improve diversity management strategies and age-balanced hiring practices in organizations are discussed.

  13. Etiologic predictive value of a rapid immunoassay for the detection of group A Streptococcus antigen from throat swabs in patients presenting with a sore throat.

    PubMed

    Orda, Ulrich; Gunnarsson, Ronny; Orda, Sabine; Fitzgerald, Mark; Rofe, Geoff; Dargan, Anna

    2016-04-01

    Clinical reasoning utilizing certain symptoms and scores has not proven to be a reliable decision-making tool to determine whether or not to suspect a group A Streptococcus (GAS) infection in the patient presenting with a sore throat. Culture as the so-called 'gold standard' is impracticable because it takes 1 to 2 days (and even longer in remote locations) for a result, and thus treatment decisions will be made without the result available. Rapid diagnostic antigen tests have demonstrated sufficient sensitivities and specificities in detecting GAS antigens to identify GAS throat infections. Throat swab samples were collected from patients attending the Mount Isa Hospital emergency department for a sore throat; these samples were compared to swab samples collected from healthy controls who did not have a sore throat. Both groups were aged 3-15 years. All swab samples were analyzed with a point-of-care test (Alere Test Pack +Plus with OBC Strep A). The etiologic predictive value (EPV) of the throat swab was calculated. The 95% confidence interval for positive EPV was 88-100% and for negative EPV was 97-99%, depending on assumptions made. This study demonstrates that the point-of-care test Alere Test Pack +Plus Strep A has a high positive predictive value and is able to rule in GAS infection as long as the proportion of carriers is low. Also the negative predictive value for ruling out GAS as the etiologic agent is very high irrespective of the carrier rate. Hence, this test is always useful to rule out GAS infection. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Diagnostic performance of automated liquid culture and molecular line probe assay in smear-negative pulmonary tuberculosis.

    PubMed

    Kotwal, Aarti; Biswas, Debasis; Raghuvanshi, Shailendra; Sindhwani, Girish; Kakati, Barnali; Sharma, Shweta

    2017-04-01

    The diagnosis of smear-negative pulmonary tuberculosis (PTB) is particularly challenging, and automated liquid culture and molecular line probe assays (LPA) may prove particularly useful. The objective of our study was to evaluate the diagnostic potential of automated liquid culture (ALC) technology and commercial LPA in sputum smear-negative PTB suspects. Spot sputum samples were collected from 145 chest-symptomatic smear-negative patients and subjected to ALC, direct drug susceptibility test (DST) testing and LPA, as per manufacturers' instructions. A diagnostic yield of 26.2% was observed among sputum smear-negative TB suspects with 47.4% of the culture isolates being either INH- and/or rifampicin-resistant. Complete agreement was observed between the results of ALC assay and LPA except for two isolates which demonstrated sensitivity to INH and rifampicin at direct DST but were rifampicin-resistant in LPA. Two novel mutations were also detected among the multidrug isolates by LPA. In view of the diagnostic challenges associated with the diagnosis of TB in sputum smear-negative patients, our study demonstrates the applicability of ALC and LPA in establishing diagnostic evidence of TB.

  15. Mindfulness during romantic conflict moderates the impact of negative partner behaviors on cortisol responses.

    PubMed

    Laurent, Heidemarie K; Hertz, Robin; Nelson, Benjamin; Laurent, Sean M

    2016-03-01

    This study was designed to test whether romantic partners' mindfulness-present moment, nonjudgmental awareness-during a conflict discussion could buffer the effects of negative partner behaviors on neuroendocrine stress responses. Heterosexual couples (n=88 dyads) provided 5 saliva samples for cortisol assay during a laboratory session involving a conflict discussion task. Conflict behaviors were coded by outside observers using the System for Coding Interactions in Dyads, and partners rated their mindfulness during the task using the Toronto Mindfulness Scale. Interactions tested using multilevel modeling revealed that participants with higher levels of mindfulness during the conflict showed either quicker cortisol recovery or an absence of slowed recovery in the presence of more negative partner behaviors. Whereas the attitudinal component of mindfulness (curiosity) moderated effects of negative partner engagement in the conflict (i.e., attempts to control, coerciveness, negativity and conflict), the attentional component of mindfulness (decentering) moderated the effect of partner disengagement (i.e., withdrawal). These findings lend support to the idea that mindfulness during a stressful interaction can mitigate the physiological impacts of negative behaviors. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Emotionally laden impulsivity interacts with affect in predicting addictive use of online sexual activity in men.

    PubMed

    Wéry, Aline; Deleuze, Jory; Canale, Natale; Billieux, Joël

    2018-01-01

    The interest in studying addictive use of online sexual activities (OSA) has grown sharply over the last decade. Despite the burgeoning number of studies conceptualizing the excessive use of OSA as an addictive disorder, few have tested its relations to impulsivity, which is known to constitute a hallmark of addictive behaviors. To address this missing gap in the literature, we tested the relationships between addictive OSA use, impulsivity traits, and affect among a convenience sample of men (N=182; age, M=29.17, SD = 9.34), building upon a theoretically driven model that distinguishes the various facets of impulsivity. Results showed that negative urgency (an impulsivity trait reflecting the tendency to act rashly in negative emotional states) and negative affect interact in predicting addictive OSA use. These results highlight the pivotal role played by negative urgency and negative affect in addictive OSA use, supporting the relevance of psychological interventions that focus on improving emotional regulation (e.g., to reduce negative affect and learn healthier coping strategies) to mitigate excessive use of OSA. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Negativity bias and task motivation: testing the effectiveness of positively versus negatively framed incentives.

    PubMed

    Goldsmith, Kelly; Dhar, Ravi

    2013-12-01

    People are frequently challenged by goals that demand effort and persistence. As a consequence, philosophers, psychologists, economists, and others have studied the factors that enhance task motivation. Using a sample of undergraduate students and a sample of working adults, we demonstrate that the manner in which an incentive is framed has implications for individuals' task motivation. In both samples we find that individuals are less motivated when an incentive is framed as a means to accrue a gain (positive framing) as compared with when the same incentive is framed as a means to avoid a loss (negative framing). Further, we provide evidence for the role of the negativity bias in this effect, and highlight specific populations for whom positive framing may be least motivating. Interestingly, we find that people's intuitions about when they will be more motivated show the opposite pattern, with people predicting that positively framed incentives will be more motivating than negatively framed incentives. We identify a lay belief in the positive correlation between enjoyment and task motivation as one possible factor contributing to the disparity between predicted and actual motivation as a result of the framing of the incentive. We conclude with a discussion of the managerial implications for these findings. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  18. A novel approach for small sample size family-based association studies: sequential tests.

    PubMed

    Ilk, Ozlem; Rajabli, Farid; Dungul, Dilay Ciglidag; Ozdag, Hilal; Ilk, Hakki Gokhan

    2011-08-01

    In this paper, we propose a sequential probability ratio test (SPRT) to overcome the problem of limited samples in studies related to complex genetic diseases. The results of this novel approach are compared with the ones obtained from the traditional transmission disequilibrium test (TDT) on simulated data. Although TDT classifies single-nucleotide polymorphisms (SNPs) to only two groups (SNPs associated with the disease and the others), SPRT has the flexibility of assigning SNPs to a third group, that is, those for which we do not have enough evidence and should keep sampling. It is shown that SPRT results in smaller ratios of false positives and negatives, as well as better accuracy and sensitivity values for classifying SNPs when compared with TDT. By using SPRT, data with small sample size become usable for an accurate association analysis.

  19. Desire thinking: A risk factor for binge eating?

    PubMed

    Spada, Marcantonio M; Caselli, Gabriele; Fernie, Bruce A; Manfredi, Chiara; Boccaletti, Fabio; Dallari, Giulia; Gandini, Federica; Pinna, Eleonora; Ruggiero, Giovanni M; Sassaroli, Sandra

    2015-08-01

    In the current study we explored the role of desire thinking in predicting binge eating independently of Body Mass Index, negative affect and irrational food beliefs. A sample of binge eaters (n=77) and a sample of non-binge eaters (n=185) completed the following self-report instruments: Hospital Anxiety and Depression Scale, Irrational Food Beliefs Scale, Desire Thinking Questionnaire, and Binge Eating Scale. Mann-Whitney U tests revealed that all variable scores were significantly higher for binge eaters than non-binge eaters. A logistic regression analysis indicated that verbal perseveration was a predictor of classification as a binge eater over and above Body Mass Index, negative affect and irrational food beliefs. A hierarchical regression analysis, on the combined sample, indicated that verbal perseveration predicted levels of binge eating independently of Body Mass Index, negative affect and irrational food beliefs. These results highlight the possible role of desire thinking as a risk factor for binge eating. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Relationship between substances in seminal plasma and Acrobeads Test results.

    PubMed

    Komori, Kazuhiko; Tsujimura, Akira; Okamoto, Yoshio; Matsuoka, Yasuhiro; Takao, Tetsuya; Miyagawa, Yasushi; Takada, Shingo; Nonomura, Norio; Okuyama, Akihiko

    2009-01-01

    To asses the effects of seminal plasma on sperm function. Retrospective case-control study. University hospital. One hundred fourteen infertile men. Acrobeads Test scores (0-4) and measurement of interleukin (IL)-6, soluble IL-6 receptor, epidermal growth factor, insulin-like growth factor-I (IGF-I), transforming growth factor-beta I, superoxide dismutase, calcitonin, and macrophage migration inhibitory factor (MIF) levels in seminal plasma. Kruskal-Wallis test to compare the concentrations of substances as a nonparametric test for differences among Acrobeads Test scores and a multivariable logistic regression model to find independent risk factors associated with abnormal Acrobeads Test results. The Acrobeads Test score was 0 for 7 samples, 1 for 20 samples, 2 for 18 samples, 3 for 28 samples, and 4 for 41 samples. Age, abstinence period, and semen parameters, except for sperm motility and percentage of sperm with abnormal morphology, had no effect on the Acrobeads Test results. Concentrations of IGF-I and MIF were significantly higher in patients with abnormal Acrobeads Test results. Multivariate analysis indicated that MIF and IGF-I were significantly associated with abnormal Acrobeads Test results (scores 0 to 1). Although further studies are needed, IGF-I and MIF in seminal plasma may have negative effects on sperm function.

  1. Amelogenin test: From forensics to quality control in clinical and biochemical genomics.

    PubMed

    Francès, F; Portolés, O; González, J I; Coltell, O; Verdú, F; Castelló, A; Corella, D

    2007-01-01

    The increasing number of samples from the biomedical genetic studies and the number of centers participating in the same involves increasing risk of mistakes in the different sample handling stages. We have evaluated the usefulness of the amelogenin test for quality control in sample identification. Amelogenin test (frequently used in forensics) was undertaken on 1224 individuals participating in a biomedical study. Concordance between referred sex in the database and amelogenin test was estimated. Additional sex-error genetic detecting systems were developed. The overall concordance rate was 99.84% (1222/1224). Two samples showed a female amelogenin test outcome, being codified as males in the database. The first, after checking sex-specific biochemical and clinical profile data was found to be due to a codification error in the database. In the second, after checking the database, no apparent error was discovered because a correct male profile was found. False negatives in amelogenin male sex determination were discarded by additional tests, and feminine sex was confirmed. A sample labeling error was revealed after a new DNA extraction. The amelogenin test is a useful quality control tool for detecting sex-identification errors in large genomic studies, and can contribute to increase its validity.

  2. Daily self-sampling for high-risk human papillomavirus (HR-HPV) testing.

    PubMed

    Sanner, Karin; Wikström, Ingrid; Gustavsson, Inger; Wilander, Erik; Lindberg, Julia Hedlund; Gyllensten, Ulf; Olovsson, Matts

    2015-12-01

    Self-sampling for HPV as part of primary screening is a well-tolerated method for women not attending organized Pap smear screening and could increase coverage of cervical cancer screening. To investigate if the prevalence of HR-HPV varies from day to day in infected women and if one single sample is reliable for detecting an ongoing infection. This is a prospective cohort study on 12 premenopausal and 13 postmenopausal women performing daily self-sampling for HR-HPV testing. They were all HR-HPV-positive 1-3 months ago. Postmenopausal women were sampled for 28 days and premenopausal women sampled during bleeding-free days in one menstrual cycle. A possible difference in viral load between the estrogen-dominated proliferative phase and the progesterone-dominated secretory phase was analyzed. Consistent results throughout the sampling period were observed for 19 women, with either a daily presence of HPV (14 women) or no HPV at all during the sampling period (5 women). Of 607 samples from 25 women, 596 were consistently positive or negative for HPV during the sampling period and 11 were inconsistent (2%). There was no difference in HPV copy number between the estrogen dominated proliferative or progesterone dominated secretory menstrual cycle phases. The major finding was a high degree of consistency concerning HR-HPV positivity and negativity of HR-HPV in vaginal fluid during a sustained period of daily self-sampling. It does not appear to matter whether the sample is collected in the proliferative or secretory phase. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Characteristics of the LacTek test as applied to tissue samples: assessment of performance using incurred field samples.

    PubMed

    Mitchell, J M; McNab, W B; Yee, A J; Griffiths, M W; McEwen, S A; Spilsbury, L; Boison, J O

    1998-08-01

    The Lactek test, marketed for antimicrobial residue detection in milk, was validated for the detection of antimicrobial residues in tissues. A previous study found that the LacTek test could confidently identify tissue samples spiked with antimicrobial residues. However, the test could not reliably distinguish violative from nonviolative spiked samples relative to Canadian maximum residue limits (MRLs). The objectives of this study were to assess and compare the performance of the LacTek tests for beta-lactams, tetracyclines, gentamicin, and sulfamethazine on samples containing naturally incurred residues by running the test in parallel with the standard microbial inhibition test (MIT) presently used for the routine testing of tissues at our facility and to assess the agreement with high pressure liquid chromatographic (HPLC) determinative methods. Parallel testing with the official MIT found that the Lactek tests could be confidently used for testing tissue samples containing incurred residues. Among 1,008 MIT-positive samples, the LacTek test found that 90% contained beta-lactams and/or tetracyclines. A further 7.3% of violative residues could not be identified to an antimicrobial class. In addition, 9% of samples testing negative on the MIT were found to contain an antimicrobial residue by the LacTek tests. Comparative testing with HPLC methods found that there was very good agreement between the two tests and that most violations were due to penicillin G and oxytetracycline. Although the LacTek test cannot be used to distinguish violative from nonviolative residue levels, it does offer several advantages over the present MIT. These include speed, ease of use, the ability to identify residues to a specific class, and an improved sensitivity at the MRL level for the most commonly found antimicrobials in tissue.

  4. Subjective Well-Being, Test Anxiety, Academic Achievement: Testing for Reciprocal Effects.

    PubMed

    Steinmayr, Ricarda; Crede, Julia; McElvany, Nele; Wirthwein, Linda

    2015-01-01

    In the context of adolescents' subjective well-being (SWB), research has recently focused on a number of different school variables. The direction of the relationships between adolescents' SWB, academic achievement, and test anxiety is, however, still open although reciprocal causation has been hypothesized. The present study set out to investigate to what extent SWB, academic achievement, and test anxiety influence each other over time. A sample of N = 290 11th grade students (n = 138 female; age: M = 16.54 years, SD = 0.57) completed measures of SWB and test anxiety in the time span of 1 year. Grade point average (GPA) indicated students' academic achievement. We analyzed the reciprocal relations using cross-lagged structural equation modeling. The model fit was satisfactory for all computed models. Results indicated that the worry component of test anxiety negatively and GPA positively predicted changes in the cognitive component of SWB (life satisfaction). Worry also negatively predicted changes in the affective component of SWB. Moreover, worry negatively predicted changes in students' GPA. Directions for future research and the differential predictive influences of academic achievement and test anxiety on adolescents' SWB are discussed with regard to potential underlying processes.

  5. Subjective Well-Being, Test Anxiety, Academic Achievement: Testing for Reciprocal Effects

    PubMed Central

    Steinmayr, Ricarda; Crede, Julia; McElvany, Nele; Wirthwein, Linda

    2016-01-01

    In the context of adolescents’ subjective well-being (SWB), research has recently focused on a number of different school variables. The direction of the relationships between adolescents’ SWB, academic achievement, and test anxiety is, however, still open although reciprocal causation has been hypothesized. The present study set out to investigate to what extent SWB, academic achievement, and test anxiety influence each other over time. A sample of N = 290 11th grade students (n = 138 female; age: M = 16.54 years, SD = 0.57) completed measures of SWB and test anxiety in the time span of 1 year. Grade point average (GPA) indicated students’ academic achievement. We analyzed the reciprocal relations using cross-lagged structural equation modeling. The model fit was satisfactory for all computed models. Results indicated that the worry component of test anxiety negatively and GPA positively predicted changes in the cognitive component of SWB (life satisfaction). Worry also negatively predicted changes in the affective component of SWB. Moreover, worry negatively predicted changes in students’ GPA. Directions for future research and the differential predictive influences of academic achievement and test anxiety on adolescents’ SWB are discussed with regard to potential underlying processes. PMID:26779096

  6. Prevalence of occult hepatitis B virus infection in hemodialysis patients in Isfahan, Iran.

    PubMed

    Kalantari, Hamid; Ferdowsi, Faezeh; Yaran, Majid

    2016-01-01

    The absence of a detectable hepatitis B surface antigen (HBsAg) with or without hepatitis B core antibody (anti-HBc) or hepatitis B surface antibody (anti-HBs) in the presence of hepatitis B virus-DNA (HBV-DNA) is defined as occult HBV infection. This study was aimed to evaluate the prevalence of occult HBV infection in patients receiving hemodialysis (HD) in Isfahan, Iran. This cross sectional study was done on 400 patients without acute or chronic HBV infection with end-stage renal disease undergoing regular HD. Blood samples were collected prior to the HD session, and serological markers of viral hepatitis B included HBsAg, anti-HBs and anti-HBc were measured using standard third generation commercially available enzyme immunoassays kit, then samples of positive anti-HBc and negative anti-HBs were tested for HBV DNA using quantitative real-time polymerase chain reaction techniques. Data were analyzed by SPSS using t -test and Chi-square test. The mean age of patients was 51.6 ± 11.2 years. Anti-HBc positive was observed in 32 (8%) of 400 studied patients with negative HBsAg. Of 32 patients with anti-HBc positive, 15 were males and 17 were females with mean age of 49.7 ± 12.6 years. Among 32 patients with anti-HBc positive, 10 patients were negative for anti-HBs. All of 10 patients were negative for HBV DNA. The prevalence of occult HBV infection was 0%. The prevalence of occult HBV infection in HBsAg negative patients undergoing HD was 0% and look to be among the lowest worldwide. So, occult HBV infection is not a significant health problem in HD patients in this region.

  7. A gel-based visual immunoassay for non-instrumental detection of chloramphenicol in food samples.

    PubMed

    Yuan, Meng; Sheng, Wei; Zhang, Yan; Wang, Junping; Yang, Yijin; Zhang, Shuguang; Goryacheva, Irina Yu; Wang, Shuo

    2012-11-02

    A gel-based non-instrumental immuno-affinity assay was developed for the rapid screening of chloramphenicol (CAP) in food samples with the limit of detection (LOD) of 1 μg L(-1). The immuno-affinity test column (IATC) consisted of a test layer containing anti-CAP antibody coupled gel, and a control layer with anti-HRP antibody coupled gel. Based on the direct competitive immuno-reaction and the horseradish peroxidase enzymatic reaction, the test results could be evaluated visually. Basically, blue color development represented the negative results, while the absence of color development represented the positive results. In this study, CAP spiked samples of raw milk, pasteurized milk, UHT milk, skimmed milk powder, acacia honey, date honey, fish and shrimp were tested. Little or none sample pretreatment was required for this assay. The whole procedure was completed within 10min. In conclusion, the gel-based immuno-affinity test is a simple, rapid, and promising on-site screening method for CAP residues in food samples, with no instrumental requirement. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Determination of HIV Status in African Adults With Discordant HIV Rapid Tests.

    PubMed

    Fogel, Jessica M; Piwowar-Manning, Estelle; Donohue, Kelsey; Cummings, Vanessa; Marzinke, Mark A; Clarke, William; Breaud, Autumn; Fiamma, Agnès; Donnell, Deborah; Kulich, Michal; Mbwambo, Jessie K K; Richter, Linda; Gray, Glenda; Sweat, Michael; Coates, Thomas J; Eshleman, Susan H

    2015-08-01

    In resource-limited settings, HIV infection is often diagnosed using 2 rapid tests. If the results are discordant, a third tie-breaker test is often used to determine HIV status. This study characterized samples with discordant rapid tests and compared different testing strategies for determining HIV status in these cases. Samples were previously collected from 173 African adults in a population-based survey who had discordant rapid test results. Samples were classified as HIV positive or HIV negative using a rigorous testing algorithm that included two fourth-generation tests, a discriminatory test, and 2 HIV RNA tests. Tie-breaker tests were evaluated, including rapid tests (1 performed in-country), a third-generation enzyme immunoassay, and two fourth-generation tests. Selected samples were further characterized using additional assays. Twenty-nine samples (16.8%) were classified as HIV positive and 24 of those samples (82.8%) had undetectable HIV RNA. Antiretroviral drugs were detected in 1 sample. Sensitivity was 8.3%-43% for the rapid tests; 24.1% for the third-generation enzyme immunoassay; 95.8% and 96.6% for the fourth-generation tests. Specificity was lower for the fourth-generation tests than the other tests. Accuracy ranged from 79.5% to 91.3%. In this population-based survey, most HIV-infected adults with discordant rapid tests were virally suppressed without antiretroviral drugs. Use of individual assays as tie-breaker tests was not a reliable method for determining HIV status in these individuals. More extensive testing algorithms that use a fourth-generation screening test with a discriminatory test and HIV RNA test are preferable for determining HIV status in these cases.

  9. Molecular diagnosis of Salmonella typhi and its virulence in suspected typhoid blood samples through nested multiplex PCR.

    PubMed

    Prabagaran, Solai Ramatchandirane; Kalaiselvi, Vellingiri; Chandramouleeswaran, Naganathan; Deepthi, Krishnan Nair Geetha; Brahmadathan, Kootallur Narayanan; Mani, Mariappa

    2017-08-01

    A nested multiplex polymerase chain reaction (PCR) based diagnosis was developed for the detection of virulent Salmonella typhi in the blood specimens from patients suspected for typhoid fever. After the Widal test, two pairs of primers were used for the detection of flagellin gene (fliC) of S. typhi. Among them, those positive for fliC alone were subjected to identification of genes in Via B operon of Salmonella Pathogenesity Island (SPI-7) where four primer pairs were used to detect tviA and tviB genes. Among 250 blood samples tested, 115 were positive by fliC PCR; 22 of these were negative for tviA and tviB. Hence, the method described here can be used to diagnose the incidence of Vi-negative serovar typhi especially in endemic regions where the Vi vaccine is administered. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Comparison of quasistatic to impact mechanical properties of multiwall carbon nanotube/polycarbonate composites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brühwiler, Paul A.; Barbezat, Michel; Necola, Adly

    2010-10-22

    We report the quasistatic tensile and impact penetration properties (falling dart test) of injection-molded polycarbonate samples, as a function of multiwall carbon nanotube (MWNT) concentration (0.0-2.5%). The MWNT were incorporated by dilution of a commercial MWNT/polycarbonate masterbatch. The stiffness and quasistatic yield strength of the composites increased approximately linearly with MWNT concentration in all measurements. The energy absorbed in fracture was, however, a negative function of the MWNT concentration, and exhibited different dependencies in quasistatic and impact tests. Small-angle x-ray scattering (SAXS) showed that the dispersion of the MWNT was similar at all concentrations. The negative effects on energy absorptionmore » are attributed to agglomerates remaining in the samples, which were observed in optical microscopy and SAXS. Overall, there was a good correspondence between static and dynamic energy absorption.« less

  11. Brief Report: High Sensitivity and Specificity of the Cepheid Xpert HIV-1 Qualitative Point-of-Care Test Among Newborns in Botswana.

    PubMed

    Ibrahim, Maryanne; Moyo, Sikhulile; Mohammed, Terence; Mupfumi, Lucy; Gaseitsiwe, Simani; Maswabi, Kenneth; Ajibola, Gbolahan; Gelman, Rebecca; Batlang, Oganne; Sakoi, Maureen; Auletta-Young, Chloe; Makhema, Joseph; Lockman, Shahin; Shapiro, Roger L

    2017-08-15

    HIV point-of-care (POC) testing allows for early infant HIV diagnosis and treatment, but POC accuracy at birth and in the setting of antiretroviral prophylaxis for the prevention of mother-to-child HIV transmission is unknown. We evaluated the Cepheid Xpert HIV-1 Qual POC test against the Roche Taqman HIV-1 DNA polymerase chain reaction (PCR) platform using dried blood spots from 15 HIV-infected and 75 HIV-exposed uninfected newborns. These infants were screened for HIV at <96 hours of life at 5 hospital maternity wards in Botswana; all infants received postexposure antiretroviral prophylaxis with single-dose nevirapine and zidovudine, and most mothers received 3-drug antiretroviral therapy in pregnancy and at delivery. Fourteen of the 15 PCR positive samples tested positive by Cepheid POC, yielding a sensitivity of 93.3% (95% confidence interval: 68.1 to 99.8). Baseline viral load among positive infants ranged from <40 to >10,000,000 copies/mL, with a median of 2403 copies/mL. The HIV RNA for the infant with false-negative POC testing was 1661 copies/mL. Of note, 2 infants with low HIV RNA (<40 and 272 copies/mL) were correctly identified as HIV positive by Cepheid POC. All the 75 PCR-negative samples tested negative by Cepheid POC, yielding a specificity of 100% (95% confidence interval: 96.1 to 100). Our study demonstrates high sensitivity and specificity for the Cepheid POC assay in the first week of life despite early infection and antiretroviral prophylaxis. This platform may be a useful approach for adding early infant HIV diagnosis to current testing programs.

  12. Application of the Capilia TB assay for culture confirmation of Mycobacterium tuberculosis complex isolates.

    PubMed

    Hillemann, D; Rüsch-Gerdes, S; Richter, E

    2005-12-01

    The usefulness of a low-tech rapid test for culture confirmation of Mycobacterium tuberculosis complex, Capilia TB, was tested on 172 mycobacteria-positive clinical samples. The overall sensitivity and specificity were 92.4% and 100%, respectively. In three of nine false-negative isolates a mutation in the mpb64 gene could be detected.

  13. Real-Time Detection Method And System For Identifying Individual Aerosol Particles

    DOEpatents

    Gard, Eric Evan; Fergenson, David Philip

    2005-10-25

    A method and system of identifying individual aerosol particles in real time. Sample aerosol particles are compared against and identified with substantially matching known particle types by producing positive and negative test spectra of an individual aerosol particle using a bipolar single particle mass spectrometer. Each test spectrum is compared to spectra of the same respective polarity in a database of predetermined positive and negative spectra for known particle types and a set of substantially matching spectra is obtained. Finally the identity of the individual aerosol particle is determined from the set of substantially matching spectra by determining a best matching one of the known particle types having both a substantially matching positive spectrum and a substantially matching negative spectrum associated with the best matching known particle type.

  14. Preventing False Negatives for Histochemical Detection of Phenolics and Lignins in PEG-Embedded Plant Tissues

    PubMed Central

    Ferreira, Bruno G.; Falcioni, Renan; Guedes, Lubia M.; Avritzer, Sofia C.; Antunes, Werner C.; Souza, Luiz A.; Isaias, Rosy M.S.

    2016-01-01

    Polyethylene glycol (PEG) is a low-cost and advantageous embedding medium, which maintains the majority of cell contents unaltered during the embedding process. Some hard or complex plant materials are better embedded in PEG than in other usual embedding media. However, the histochemical tests for phenolics and lignins in PEG-embedded plant tissues commonly result in false negatives. We hypothesize that these false negatives should be prevented by the use of distinct fixatives, which should avoid the bonds between PEG and phenols. Novel protocols for phenolics and flavanols detection are efficiently tested, with fixation of the samples in ferrous sulfate and formalin or in caffeine and sodium benzoate, respectively. The differentiation of lignin types is possible in safranin-stained sections observed under fluorescence. The Maule’s test faultlessly distinguishes syringyl-rich from guaiacyl- and hydroxyphenyl-rich lignins in PEG-embedded material under light microscopy. Current hypothesis is corroborated, that is, the adequate fixation solves the false-negative results, and the new proposed protocols fill up some gaps on the detection of phenolics and lignins. PMID:28117630

  15. Rapid Determination of Salmonella in Samples of Egg Noodles, Cake Mixes, and Candies

    PubMed Central

    Banwart, George J.; Kreitzer, Madeleine J.

    1969-01-01

    A glass apparatus system was compared with a standard enrichment broth-selective agar method to test samples of egg noodles, cake mixes, and candy for the presence or absence of salmonellae. The glass apparatus system used fermentation of mannitol, production of H2S, or motility, in conjunction with a serological test of flagellar antigens, to detect salmonellae. No salmonellae were detected in 173 samples of food products. Of these samples, 171 were found to be Salmonella-negative after 48 hr with the glass apparatus system. After 72 hr, the standard Salmonella procedure yielded 38 samples which produced Salmonella false-positive results on selective agars. Inoculation of samples with cultures of Salmonella showed that approximately one inoculated cell could be detected after 48 hr of incubation with the glass apparatus. The standard Salmonella test requires a minimum of 72 hr for completion. Compared with the standard Salmonella test, the glass apparatus system is a more rapid and simple system that can be used to determine the presence or absence of Salmonella in these food products. Images PMID:5370460

  16. 'Testing Together Challenges the Relationship': Consequences of HIV Testing as a Couple in a High HIV Prevalence Setting in Rural South Africa.

    PubMed

    Tabana, Hanani; Doherty, Tanya; Rubenson, Birgitta; Jackson, Debra; Ekström, Anna Mia; Thorson, Anna

    2013-01-01

    We conducted qualitative individual and combined interviews with couples to explore their experiences since the time of taking an HIV test and receiving the test result together, as part of a home-based HIV counselling and testing intervention. This study was conducted in October 2011 in rural KwaZulu-Natal, South Africa, about 2 years after couples tested and received results together. Fourteen couples were purposively sampled: discordant, concordant negative and concordant positive couples. Learning about each other's status together challenged relationships of the couples in different ways depending on HIV status and gender. The mutual information confirmed suspected infidelity that had not been discussed before. Negative women in discordant partnerships remained with their positive partner due to social pressure and struggled to maintain their HIV negative status. Most of the couple relationships were characterized by silence and mistrust. Knowledge of sero-status also led to loss of sexual intimacy in some couples especially the discordant. For most men in concordant negative couples, knowledge of status was an awakening of the importance of fidelity and an opportunity for behaviour change, while for concordant positive and discordant couples, it was seen as proof of infidelity. Although positive HIV status was perceived as confirmation of infidelity, couples continued their relationship and offered some support for each other, living and managing life together. Sexual life in these couples was characterized by conflict and sometimes violence. In the concordant negative couples, trust was enhanced and behaviour change was promised. Findings suggest that testing together as couples challenged relationships in both negative and positive ways. Further, knowledge of HIV status indicated potential to influence behaviour change especially among concordant negatives. In the discordant and concordant positive couples, traditional gender roles exposed women's vulnerability and their lack of decision-making power.

  17. Development of a PCR Assay for Diagnosing Trematode (Opisthorchis and Haplorchis) Infections in Human Stools

    PubMed Central

    Kanda, Seiji; Laimanivong, Sakhone; Shimono, Takaki; Darcy, Andrew Waleluma; Phyaluanglath, Amphay; Mishima, Nobuyuki; Nishiyama, Toshimasa

    2017-01-01

    We developed a combined conventional polymerase chain reaction (PCR) and real-time PCR (qPCR)-based assay for detecting and discriminating between Opisthorchis viverrini and Haplorchis taichui parasite infections. The first PCR amplifies the mitochondrial cytochrome c oxidase subunit I (COI) genes of parasites, and differential diagnosis is achieved by performing qPCR with specific primers and SYBR Green I. The detection limit of the assay was found to be 2.0 × 102 plasmid copies in a test in which a stool sample was spiked with a single egg, which is equivalent to 5 eggs per gram (EPG). The testing of 34 clinical stool samples that had been demonstrated to contain “Opisthorchis-like” eggs by microscopy showed that the novel assay exhibited a sensitivity of 100% for “Opisthorchis-like” parasitic infections, and 71% and 91% of these samples were found to be infected with O. viverrini and H. taichui, respectively. A further four parasitic infections were diagnosed in the 16 negative samples, and the microscopic findings of these samples were confirmed to be false negatives by sequencing analysis. The assay also displayed high specificity during the testing of 10 samples containing other common parasites. The fact that our qPCR SYBR Green I–based assay detected submicroscopic traces of parasitic DNA and was able to differentiate between parasites that produce eggs with similar morphologies indicates that it has a good potential for development of diagnostic application to use in areas where multiple parasites coexist. PMID:27821695

  18. Engagement with HIV prevention treatment and care among female sex workers in Zimbabwe: a respondent driven sampling survey.

    PubMed

    Cowan, Frances M; Mtetwa, Sibongile; Davey, Calum; Fearon, Elizabeth; Dirawo, Jeffrey; Wong-Gruenwald, Ramona; Ndikudze, Theresa; Chidiya, Samson; Benedikt, Clemens; Busza, Joanna; Hargreaves, James R

    2013-01-01

    To determine the HIV prevalence and extent of engagement with HIV prevention and care among a representative sample of Zimbabwean sex workers working in Victoria Falls, Hwange and Mutare. Respondent driven sampling (RDS) surveys conducted at each site. Sex workers were recruited using respondent driven sampling with each respondent limited to recruiting 2 peers. Participants completed an interviewer-administered questionnaire and provided a finger prick blood sample for HIV antibody testing. Statistical analysis took account of sampling method. 870 women were recruited from the three sites. HIV prevalence was between 50 and 70%. Around half of those confirmed HIV positive were aware of their HIV status and of those 50-70% reported being enrolled in HIV care programmes. Overall only 25-35% of those with laboratory-confirmed HIV were accessing antiretroviral therapy. Among those reporting they were HIV negative, 21-28% reported having an HIV test in the last 6 months. Of those tested HIV negative, most (65-82%) were unaware of their status. Around two-thirds of sex workers reported consistent condom use with their clients. As in other settings, sex workers reported high rates of gender based violence and police harassment. This survey suggests that prevalence of HIV is high among sex workers in Zimbabwe and that their engagement with prevention, treatment and care is sub-optimal. Intensifying prevention and care interventions for sex workers has the potential to markedly reduce HIV and social risks for sex workers, their clients and the general population in Zimbabwe and elsewhere in the region.

  19. False-Negative Rate and Recovery Efficiency Performance of a Validated Sponge Wipe Sampling Method

    PubMed Central

    Piepel, Greg F.; Boucher, Raymond; Tezak, Matt; Amidan, Brett G.; Einfeld, Wayne

    2012-01-01

    Recovery of spores from environmental surfaces varies due to sampling and analysis methods, spore size and characteristics, surface materials, and environmental conditions. Tests were performed to evaluate a new, validated sponge wipe method using Bacillus atrophaeus spores. Testing evaluated the effects of spore concentration and surface material on recovery efficiency (RE), false-negative rate (FNR), limit of detection (LOD), and their uncertainties. Ceramic tile and stainless steel had the highest mean RE values (48.9 and 48.1%, respectively). Faux leather, vinyl tile, and painted wood had mean RE values of 30.3, 25.6, and 25.5, respectively, while plastic had the lowest mean RE (9.8%). Results show roughly linear dependences of RE and FNR on surface roughness, with smoother surfaces resulting in higher mean REs and lower FNRs. REs were not influenced by the low spore concentrations tested (3.10 × 10−3 to 1.86 CFU/cm2). Stainless steel had the lowest mean FNR (0.123), and plastic had the highest mean FNR (0.479). The LOD90 (≥1 CFU detected 90% of the time) varied with surface material, from 0.015 CFU/cm2 on stainless steel up to 0.039 on plastic. It may be possible to improve sampling results by considering surface roughness in selecting sampling locations and interpreting spore recovery data. Further, FNR values (calculated as a function of concentration and surface material) can be used presampling to calculate the numbers of samples for statistical sampling plans with desired performance and postsampling to calculate the confidence in characterization and clearance decisions. PMID:22138998

  20. Detection of Bovine and Porcine Adenoviruses for Tracing the Source of Fecal Contamination

    PubMed Central

    Maluquer de Motes, Carlos; Clemente-Casares, Pilar; Hundesa, Ayalkibet; Martín, Margarita; Girones, Rosina

    2004-01-01

    In this study, a molecular procedure for the detection of adenoviruses of animal origin was developed to evaluate the level of excretion of these viruses by swine and cattle and to design a test to facilitate the tracing of specific sources of environmental viral contamination. Two sets of oligonucleotides were designed, one to detect porcine adenoviruses and the other to detect bovine and ovine adenoviruses. The specificity of the assays was assessed in 31 fecal samples and 12 sewage samples that were collected monthly during a 1-year period. The data also provided information on the environmental prevalence of animal adenoviruses. Porcine adenoviruses were detected in 17 of 24 (70%) pools of swine samples studied, with most isolates being closely related to serotype 3. Bovine adenoviruses were present in 6 of 8 (75%) pools studied, with strains belonging to the genera Mastadenovirus and Atadenovirus and being similar to bovine adenoviruses of types 2, 4, and 7. These sets of primers produced negative results in nested PCR assays when human adenovirus controls and urban-sewage samples were tested. Likewise, the sets of primers previously designed for detection of human adenovirus also produced negative results with animal adenoviruses. These results indicate the importance of further studies to evaluate the usefulness of these tests to trace the source of fecal contamination in water and food and for environmental studies. PMID:15006765

  1. Evidence of the presence of the Zika virus in Mexico since early 2015.

    PubMed

    Díaz-Quiñonez, José Alberto; López-Martínez, Irma; Torres-Longoria, Belem; Vázquez-Pichardo, Mauricio; Cruz-Ramírez, Edith; Ramírez-González, José Ernesto; Ruiz-Matus, Cuitláhuac; Kuri-Morales, Pablo

    2016-12-01

    To assess the possible circulation of Zika virus (ZIKV) prior to the first documented case in Mexico, we reanalyzed the stored samples from the states of Veracruz and Yucatán, which were originally collected to test for dengue (DENV) and chikungunya (CHIKV) but were negative for these viruses despite the symptomatology. The samples were originally collected between the 30 and 46 epidemiological weeks (EW) when the ZIKV was not yet declared as a Public Health Emergency of International Concern (PHEIC). From the total 4016 negative samples, a total of one hundred samples, 50 from Veracruz (CHIK - DENV - ) and 50 from Yucatán (4 CHIK - DENV - and 46 CHIK - or DENV - ), were tested for Zika virus by using RT-PCR. Results showed that in Veracruz and Yucatán, 20 % (10/50) and 70 % (35/50) were, respectively, ZIKV positive, indicating unequivocally the presence of ZIKV at least since July 2015. We also tested non-confirmed suspect measles cases from early 2015 for ZIKV by RT-PCR. Remarkably in 11 Mexican states, 86 % (18/21) were positive with the earlier symptoms onset as early as May 2015. Finally, RT-PCR analyses on RNA extracted from Aedes aegypti mosquitoes captured from January to March 2015 showed the presence of ZIKV, strongly suggesting that the vector was already carrying the virus at the start of 2015.

  2. Detection of bovine and porcine adenoviruses for tracing the source of fecal contamination.

    PubMed

    Maluquer de Motes, Carlos; Clemente-Casares, Pilar; Hundesa, Ayalkibet; Martín, Margarita; Girones, Rosina

    2004-03-01

    In this study, a molecular procedure for the detection of adenoviruses of animal origin was developed to evaluate the level of excretion of these viruses by swine and cattle and to design a test to facilitate the tracing of specific sources of environmental viral contamination. Two sets of oligonucleotides were designed, one to detect porcine adenoviruses and the other to detect bovine and ovine adenoviruses. The specificity of the assays was assessed in 31 fecal samples and 12 sewage samples that were collected monthly during a 1-year period. The data also provided information on the environmental prevalence of animal adenoviruses. Porcine adenoviruses were detected in 17 of 24 (70%) pools of swine samples studied, with most isolates being closely related to serotype 3. Bovine adenoviruses were present in 6 of 8 (75%) pools studied, with strains belonging to the genera Mastadenovirus and Atadenovirus and being similar to bovine adenoviruses of types 2, 4, and 7. These sets of primers produced negative results in nested PCR assays when human adenovirus controls and urban-sewage samples were tested. Likewise, the sets of primers previously designed for detection of human adenovirus also produced negative results with animal adenoviruses. These results indicate the importance of further studies to evaluate the usefulness of these tests to trace the source of fecal contamination in water and food and for environmental studies.

  3. Dipstick Test for Rapid Diagnosis of Shigella dysenteriae 1 in Bacterial Cultures and Its Potential Use on Stool Samples

    PubMed Central

    Taneja, Neelam; Nato, Faridabano; Dartevelle, Sylvie; Sire, Jean Marie; Garin, Benoit; Thi Phuong, Lan Nguyen; Diep, Tai The; Shako, Jean Christophe; Bimet, François; Filliol, Ingrid; Muyembe, Jean-Jacques; Ungeheuer, Marie Noëlle; Ottone, Catherine; Sansonetti, Philippe; Germani, Yves

    2011-01-01

    Background We describe a test for rapid detection of S. dysenteriae 1 in bacterial cultures and in stools, at the bedside of patients. Methodology/Principal Findings The test is based on the detection of S. dysenteriae 1 lipopolysaccharide (LPS) using serotype 1-specific monoclonal antibodies coupled to gold particles and displayed on a one-step immunochromatographic dipstick. A concentration as low as 15 ng/ml of LPS was detected in distilled water and in reconstituted stools in 10 minutes. In distilled water and in reconstituted stools, an unequivocal positive reaction was obtained with 1.6×106 CFU/ml and 4.9×106 CFU/ml of S. dysenteriae 1, respectively. Optimal conditions to read the test have been determined to limit the risk of ambiguous results due to appearance of a faint yellow test band in some negative samples. The specificity was 100% when tested with a battery of Shigella and unrelated strains in culture. When tested on 328 clinical samples in India, Vietnam, Senegal and France by laboratory technicians and in Democratic Republic of Congo by a field technician, the specificity (312/316) was 98.7% (95% CI:96.6–99.6%) and the sensitivity (11/12) was 91.7% (95% CI:59.8–99.6%). Stool cultures and the immunochromatographic test showed concordant results in 98.4 % of cases (323/328) in comparative studies. Positive and negative predictive values were 73.3% (95% CI:44.8–91.1%) and 99.7% (95% CI:98–100%). Conclusion The initial findings presented here for a simple dipstick-based test to diagnose S. dysenteriae 1 demonstrates its promising potential to become a powerful tool for case management and epidemiological surveys. PMID:21984895

  4. Near-infrared Raman spectroscopy to detect anti-Toxoplasma gondii antibody in blood sera of domestic cats: quantitative analysis based on partial least-squares multivariate statistics

    NASA Astrophysics Data System (ADS)

    Duarte, Janaína; Pacheco, Marcos T. T.; Villaverde, Antonio Balbin; Machado, Rosangela Z.; Zângaro, Renato A.; Silveira, Landulfo

    2010-07-01

    Toxoplasmosis is an important zoonosis in public health because domestic cats are the main agents responsible for the transmission of this disease in Brazil. We investigate a method for diagnosing toxoplasmosis based on Raman spectroscopy. Dispersive near-infrared Raman spectra are used to quantify anti-Toxoplasma gondii (IgG) antibodies in blood sera from domestic cats. An 830-nm laser is used for sample excitation, and a dispersive spectrometer is used to detect the Raman scattering. A serological test is performed in all serum samples by the enzyme-linked immunosorbent assay (ELISA) for validation. Raman spectra are taken from 59 blood serum samples and a quantification model is implemented based on partial least squares (PLS) to quantify the sample's serology by Raman spectra compared to the results provided by the ELISA test. Based on the serological values provided by the Raman/PLS model, diagnostic parameters such as sensitivity, specificity, accuracy, positive prediction values, and negative prediction values are calculated to discriminate negative from positive samples, obtaining 100, 80, 90, 83.3, and 100%, respectively. Raman spectroscopy, associated with the PLS, is promising as a serological assay for toxoplasmosis, enabling fast and sensitive diagnosis.

  5. Desire thinking: what is it and what drives it?

    PubMed

    Caselli, Gabriele; Spada, Marcantonio M

    2015-05-01

    The aim of this study was to provide an overview of the construct of desire thinking and test a metacognitive model of desire thinking and craving, based on the work of Spada, Caselli and Wells (2012; 2013), which aims to explain the perseveration of desire thinking. We conducted two studies involving four clinical samples (total N = 493) and a community sample (N = 494) presenting with different addictive behaviors. The relationships among variables were examined by testing the fit of path models within each sample. In the model presented it was proposed that positive metacognitions about desire thinking are associated with, in turn, imaginal prefiguration and verbal perseveration, marking the activation of desire thinking. Verbal perseveration is then associated to negative metacognitions about desire thinking and craving denoting the pathological escalation of desire thinking. Finally, a direct association between positive metacognitions about desire thinking and negative metacognitions about desire thinking would mark those occasions where target-achieving behaviour runs as an automatized schemata without the experience of craving. Results indicated a good model fit in the clinical sample and a variation in the model structure in the community sample. These findings provide further support for the application of metacognitive theory to desire thinking and craving in addictive behaviors. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Comparison of the diagnostic performance of bacterial culture of nasopharyngeal swab and bronchoalveolar lavage fluid samples obtained from calves with bovine respiratory disease.

    PubMed

    Capik, Sarah F; White, Brad J; Lubbers, Brian V; Apley, Michael D; DeDonder, Keith D; Larson, Robert L; Harhay, Greg P; Chitko-McKown, Carol G; Harhay, Dayna M; Kalbfleisch, Ted S; Schuller, Gennie; Clawson, Michael L

    2017-03-01

    OBJECTIVE To compare predictive values, extent of agreement, and gamithromycin susceptibility between bacterial culture results of nasopharyngeal swab (NPS) and bronchoalveolar lavage fluid (BALF) samples obtained from calves with bovine respiratory disease (BRD). ANIMALS 28 beef calves with clinical BRD. PROCEDURES Pooled bilateral NPS samples and BALF samples were obtained for bacterial culture from calves immediately before and at various times during the 5 days after gamithromycin (6 mg/kg, SC, once) administration. For each culture-positive sample, up to 12 Mannheimia haemolytica, 6 Pasteurella multocida, and 6 Histophilus somni colonies underwent gamithromycin susceptibility testing. Whole-genome sequencing was performed on all M haemolytica isolates. For paired NPS and BALF samples collected 5 days after gamithromycin administration, the positive and negative predictive values for culture results of NPS samples relative to those of BALF samples and the extent of agreement between the sampling methods were determined. RESULTS Positive and negative predictive values of NPS samples were 67% and 100% for M haemolytica, 75% and 100% for P multocida, and 100% and 96% for H somni. Extent of agreement between results for NPS and BALF samples was substantial for M haemolytica (κ, 0.71) and H somni (κ, 0.78) and almost perfect for P multocida (κ, 0.81). Gamithromycin susceptibility varied within the same sample and between paired NPS and BALF samples. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated culture results of NPS and BALF samples from calves with BRD should be interpreted cautiously considering disease prevalence within the population, sample collection relative to antimicrobial administration, and limitations of diagnostic testing methods.

  7. The prospective effects of impulsivity on alcohol and tobacco use in a college sample.

    PubMed

    Doran, Neal; Trim, Ryan S

    2013-01-01

    Alcohol and tobacco use are strongly associated, particularly in younger populations, and concurrent use may encourage progression toward dependence on both substances. Impulsivity has been linked to the use of alcohol and tobacco individually, but has not been studied in terms of its association with use of both. This study tested the hypothesis that the effects of impulsivity (sensation seeking and negative urgency) on smoking initiation in a sample of college students (n = 400) would be mediated by alcohol consumption. We also predicted that sensation seeking and negative urgency would predict alcohol and cigarette use and overlap among initiators. Sensation seeking and negative urgency both predicted smoking initiation, but only the former effect was mediated by alcohol use. Among initiators, sensation seeking was associated with more frequent alcohol use as well as more frequent overlap between alcohol and tobacco use but not with smoking frequency. Higher negative urgency was associated with more frequent smoking, but not with alcohol use or alcohol/tobacco overlap. Findings are consistent with previous research in college samples and suggest the existence of multiple pathways to alcohol and tobacco use and co-use in college students.

  8. Administration of antibiotic agents before intraoperative sampling in orthopedic infections alters culture results.

    PubMed

    Al-Mayahi, Mohamed; Cian, Anais; Lipsky, Benjamin A; Suvà, Domizio; Müller, Camillo; Landelle, Caroline; Miozzari, Hermès H; Uçkay, Ilker

    2015-11-01

    Many physicians and surgeons think that prescribing antibiotics before intraoperative sampling does not alter the microbiological results. Case-control study of adult patients hospitalized with orthopedic infections. Among 2740 episodes of orthopedic infections, 1167 (43%) had received antibiotic therapy before surgical sampling. Among these, 220 (19%) grew no pathogens while the proportion of culture-negative results in the 2573 who had no preoperative antibiotic therapy was only 6%. By multivariate analyses, pre-operative antibiotic exposure was associated with significantly more culture-negative results (odds ratio 2.8, 95% confidence interval 2.1-3.7), more non-fermenting rods and skin commensals (odds ratio 2.8 and 3.0, respectively). Even a single pre-operative dose of antibiotic was significantly associated with subsequent culture-negative results (19/93 vs. 297/2350; χ²-test, p = 0.01) and skin commensals (17/74 vs. 274/2350; p = 0.01) compared to episodes without preceding prophylaxis. Prior antibiotic use, including single-dose prophylactic administrations, is three-fold associated with culture-negative results, non-fermenting rods and resistant skin commensals. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  9. Differential diagnosis of urothelial carcinoma in situ from non-neoplastic urothelia: Analysis of CK20, CD44, P53 and Ki67

    PubMed Central

    Asgari, Mojgan; Nabi Maybodi, Mahtab; Abolhasani, Maryam

    2016-01-01

    Background: Flat urothelial lesions comprise a spectrum of morphologic changes ranging from reactive atypia to carcinoma in situ (CIS). Urothelial dysplasia and CIS are associated with the recurrence and progression of urothelial carcinoma. Distinguishing CIS and dysplasia from reactive atypia based on histolopathogical features alone is often difficult. Using different immunohistochemical markers such as Cytokeratin 20 (CK20), CD44, p53, and Ki-67 is recommended for differential diagnosis. The aim of this study was to evaluate the immunohistochemical pattern of these antibodies to differentiate different flat urothelial lesions. Methods: In this cross- sectional study, three groups of bladder biopsy specimens were evaluated: 20 samples with reactive urothelial lesions, 20 histologically diagnosed as CIS, and 20 morphologically normal samples. Immunohistochemical staining of CK20, p53, CD44 and Ki-67 markers was performed on paraffin-embedded blocks. The groups were compared using chi square test, and the diagnostic value of the markers were evaluated with sensitivity, specificity, positive and negative predictive values. Results: CK20 was full thickness positive in 15 (75%) CIS samples and negative in all samples of the normal and reactive groups (p<0.001); CD44 was positive in 2 (10%) cases of the CIS group and in 17 (85%) of the reactive group; this marker was negative in all the normal samples (p<0.001). P53 was positive in 12 (60%) samples of the CIS group and negative in all samples of the normal and reactive groups (p<0.001). Ki67 was positive in 13 (65%) samples of the CIS group and 1 (5%) sample of the reactive group. This marker was negative in all samples of the normal group (p<0.001). Conclusion: The results of this study revealed that CK20, CD44, P53 and Ki67 are useful in distinguishing CIS from reactive and normal samples. However, they should be used in a panel including at least three markers. Correlation with the morphologic features is necessary. PMID:27579290

  10. Comparison of molecular tests for the diagnosis of malaria in Honduras

    PubMed Central

    2012-01-01

    Background Honduras is a tropical country with more than 70% of its population living at risk of being infected with either Plasmodium vivax or Plasmodium falciparum. Laboratory diagnosis is a very important factor for adequate treatment and management of malaria. In Honduras, malaria is diagnosed by both, microscopy and rapid diagnostic tests and to date, no molecular methods have been implemented for routine diagnosis. However, since mixed infections, and asymptomatic and low-parasitaemic cases are difficult to detect by light microscopy alone, identifying appropriate molecular tools for diagnostic applications in Honduras deserves further study. The present study investigated the utility of different molecular tests for the diagnosis of malaria in Honduras. Methods A total of 138 blood samples collected as part of a clinical trial to assess the efficacy of chloroquine were used: 69 microscopically confirmed P. falciparum positive samples obtained on the day of enrolment and 69 follow-up samples obtained 28 days after chloroquine treatment and shown to be malaria negative by microscopy. Sensitivity and specificity of microscopy was compared to an 18 s ribosomal RNA gene-based nested PCR, two single-PCR reactions designed to detect Plasmodium falciparum infections, one single-PCR to detect Plasmodium vivax infections, and one multiplex one-step PCR reaction to detect both parasite species. Results Of the 69 microscopically positive P. falciparum samples, 68 were confirmed to be P. falciparum-positive by two of the molecular tests used. The one sample not detected as P. falciparum by any of the molecular tests was shown to be P. vivax-positive by a reference molecular test indicating a misdiagnosis by microscopy. The reference molecular test detected five cases of P. vivax/P. falciparum mixed infections, which were not recognized by microscopy as mixed infections. Only two of these mixed infections were recognized by a multiplex test while a P. vivax-specific polymerase chain reaction (PCR) detected three of them. In addition, one of the day 28 samples, previously determined to be malaria negative by microscopy, was shown to be P. vivax-positive by three of the molecular tests specific for this parasite. Conclusions Molecular tests are valuable tools for the confirmation of Plasmodium species and in detecting mixed infections in malaria endemic regions. PMID:22513192

  11. Comparison of molecular tests for the diagnosis of malaria in Honduras.

    PubMed

    Fontecha, Gustavo A; Mendoza, Meisy; Banegas, Engels; Poorak, Mitra; De Oliveira, Alexandre M; Mancero, Tamara; Udhayakumar, Venkatachalam; Lucchi, Naomi W; Mejia, Rosa E

    2012-04-18

    Honduras is a tropical country with more than 70% of its population living at risk of being infected with either Plasmodium vivax or Plasmodium falciparum. Laboratory diagnosis is a very important factor for adequate treatment and management of malaria. In Honduras, malaria is diagnosed by both, microscopy and rapid diagnostic tests and to date, no molecular methods have been implemented for routine diagnosis. However, since mixed infections, and asymptomatic and low-parasitaemic cases are difficult to detect by light microscopy alone, identifying appropriate molecular tools for diagnostic applications in Honduras deserves further study. The present study investigated the utility of different molecular tests for the diagnosis of malaria in Honduras. A total of 138 blood samples collected as part of a clinical trial to assess the efficacy of chloroquine were used: 69 microscopically confirmed P. falciparum positive samples obtained on the day of enrollment and 69 follow-up samples obtained 28 days after chloroquine treatment and shown to be malaria negative by microscopy. Sensitivity and specificity of microscopy was compared to an 18 s ribosomal RNA gene-based nested PCR, two single-PCR reactions designed to detect Plasmodium falciparum infections, one single-PCR to detect Plasmodium vivax infections, and one multiplex one-step PCR reaction to detect both parasite species. Of the 69 microscopically positive P. falciparum samples, 68 were confirmed to be P. falciparum-positive by two of the molecular tests used. The one sample not detected as P. falciparum by any of the molecular tests was shown to be P. vivax-positive by a reference molecular test indicating a misdiagnosis by microscopy. The reference molecular test detected five cases of P. vivax/P. falciparum mixed infections, which were not recognized by microscopy as mixed infections. Only two of these mixed infections were recognized by a multiplex test while a P. vivax-specific polymerase chain reaction (PCR) detected three of them. In addition, one of the day 28 samples, previously determined to be malaria negative by microscopy, was shown to be P. vivax-positive by three of the molecular tests specific for this parasite. Molecular tests are valuable tools for the confirmation of Plasmodium species and in detecting mixed infections in malaria endemic regions.

  12. HIV testing behaviors of a cohort of HIV-positive racial/ethnic minority YMSM.

    PubMed

    Phillips, Gregory; Hightow-Weidman, Lisa B; Arya, Monisha; Fields, Sheldon D; Halpern-Felsher, Bonnie; Outlaw, Angulique Y; Wohl, Amy R; Hidalgo, Julia

    2012-10-01

    The HIV epidemic in the United States has disproportionately affected young racial/ethnic minority men who have sex with men (YMSM). However, HIV testing rates among young men of color remain low. Within this sample of racial/ethnic minority YMSM (n = 363), the first HIV test was a median of 2 years after men who have sex with men sexual debut. Individuals with less than 1 year between their first negative and first positive HIV test were significantly more likely to identify the reason for their first negative test as being sick (OR = 2.99; 95 % CI 1.23-7.27). This may suggest that these YMSM may have experienced symptoms of acute HIV infection. Of major concern is that many YMSM in our study tested positive for HIV on their first HIV test. Given recommendations for at least annual HIV testing, our findings reveal that medical providers YMSM need to know the importance of regular testing.

  13. Obsessive-Compulsive Symptoms and Negative Affect During Tobacco Withdrawal in a Non-Clinical Sample of African American Smokers

    PubMed Central

    Bello, Mariel S.; Pang, Raina D.; Chasson, Gregory S.; Ray, Lara A.; Leventhal, Adam M.

    2016-01-01

    The association between obsessive-compulsive (OC) symptomatology and smoking is poorly understood, particularly in African Americans—a group subject to smoking- and OC-related health disparities. In a non-clinical sample of 253 African American smokers, we tested the negative reinforcement model of OC-smoking comorbidity, purporting that smokers with higher OC symptoms experience greater negative affect (NA) and urge to smoke for NA suppression upon acute tobacco abstinence. Following a baseline visit involving OC assessment, participants completed two counterbalanced experimental visits (non-abstinent vs. 16-hr tobacco abstinence) involving affect, smoking urge, and nicotine withdrawal assessment. OC symptom severity predicted larger abstinence-provoked increases in overall NA, anger, anxiety, depression, fatigue, urge to smoke to suppress NA, and composite nicotine withdrawal symptom index. African American smokers with elevated OC symptoms appear to be vulnerable to negative reinforcement-mediated smoking motivation and may benefit from cessation treatments that diminish NA or the urge to quell NA via smoking. PMID:27769664

  14. The Upside of Being Socially Anxious: Psychopathic Attributes and Social Anxiety are Negatively Associated

    PubMed Central

    Hofmann, Stefan G.; Korte, Kristina J.; Suvak, Michael K.

    2009-01-01

    Psychopathy is characterized by a lack of concern for other people and social norms. In contrast, individuals with high social anxiety are overly concerned about the approval of others and violating social norms. Therefore, we hypothesized that social anxiety is negatively associated with psychopathic attributes, with males being more psychopathic than females. In order to test this hypothesis, we administered self-report measures of social anxiety, psychopathic attributes, and academic misconduct as an index of adherence to social norms to a sample of 349 undergraduate college students (244 females and 105 males). Males had more psychopathic attributes than females. Social anxiety and psychopathic attributes showed a weak but significant negative correlation in the total sample and also in the subgroup of males and females. Psychopathic attributes were further positively associated with academic misconduct behaviors among females, but not among males. These findings are consistent with the notion that social anxiety and psychopathic attributes are negatively associated. PMID:19777142

  15. Functional proteomics outlines the complexity of breast cancer molecular subtypes.

    PubMed

    Gámez-Pozo, Angelo; Trilla-Fuertes, Lucía; Berges-Soria, Julia; Selevsek, Nathalie; López-Vacas, Rocío; Díaz-Almirón, Mariana; Nanni, Paolo; Arevalillo, Jorge M; Navarro, Hilario; Grossmann, Jonas; Gayá Moreno, Francisco; Gómez Rioja, Rubén; Prado-Vázquez, Guillermo; Zapater-Moros, Andrea; Main, Paloma; Feliú, Jaime; Martínez Del Prado, Purificación; Zamora, Pilar; Ciruelos, Eva; Espinosa, Enrique; Fresno Vara, Juan Ángel

    2017-08-30

    Breast cancer is a heterogeneous disease comprising a variety of entities with various genetic backgrounds. Estrogen receptor-positive, human epidermal growth factor receptor 2-negative tumors typically have a favorable outcome; however, some patients eventually relapse, which suggests some heterogeneity within this category. In the present study, we used proteomics and miRNA profiling techniques to characterize a set of 102 either estrogen receptor-positive (ER+)/progesterone receptor-positive (PR+) or triple-negative formalin-fixed, paraffin-embedded breast tumors. Protein expression-based probabilistic graphical models and flux balance analyses revealed that some ER+/PR+ samples had a protein expression profile similar to that of triple-negative samples and had a clinical outcome similar to those with triple-negative disease. This probabilistic graphical model-based classification had prognostic value in patients with luminal A breast cancer. This prognostic information was independent of that provided by standard genomic tests for breast cancer, such as MammaPrint, OncoType Dx and the 8-gene Score.

  16. Higher atypical enteropathogenic Escherichia coli (a-EPEC) bacterial loads in children with diarrhea are associated with PCR detection of the EHEC factor for adherence 1/lymphocyte inhibitory factor A (efa1/lifa) gene.

    PubMed

    Slinger, Robert; Lau, Kimberley; Slinger, Michael; Moldovan, Ioana; Chan, Francis

    2017-03-23

    Typical enteropathogenic Escherichia coli (t-EPEC) are known to cause diarrhea in children but it is uncertain whether atypical EPEC (a-EPEC) do, since a-EPEC lack the bundle-forming pilus (bfp) gene that encodes a key adherence factor in t-EPEC. In culture-based studies of a-EPEC, the presence of another adherence factor, called EHEC factor for adherence/lymphocyte activation inhibitor (efa1/lifA), was strongly associated with diarrhea. Since a-EPEC culture is not feasible in clinical laboratories, we designed an efa1/lifA quantitative PCR assay and examined whether the presence of efa1/lifA was associated with higher a-EPEC bacterial loads in pediatric diarrheal stool samples. Fecal samples from children with diarrhea were tested by qPCR for EPEC (presence of eae gene) and for shiga toxin genes to exclude enterohemorrhagic E. coli, which also contain the eae gene. EPEC containing samples were then tested for the bundle-forming pilus gene found in t-EPEC and efa1/lifA. The eae gene quantity in efa1/lifA-positive and negative samples was compared. Thirty-nine of 320 (12%) fecal samples tested positive for EPEC and 38/39 (97%) contained a-EPEC. The efa1/lifA gene was detected in 16/38 (42%) a-EPEC samples. The median eae concentration for efa1/lifA positive samples was significantly higher than for efa1/lifA negative samples (median 16,745 vs. 1183 copies/µL, respectively, p = 0.006). Atypical enteropathogenic E. coli-positive diarrheal stool samples containing the efa1/lifA gene had significantly higher bacterial loads than samples lacking this gene. This supports the idea that efa1/lifA contributes to diarrheal pathogenesis and suggests that, in EPEC-positive samples, efa/lifA may be a useful additional molecular biomarker.

  17. Adverse effects of members of the Enterobacteriaceae family on boar sperm quality.

    PubMed

    Ubeda, Juan Luis; Ausejo, Raquel; Dahmani, Yahya; Falceto, Maria V; Usan, Adan; Malo, Clara; Perez-Martinez, Francisco C

    2013-10-01

    Semen samples collected in 2012 from 1785 boars belonging to five different breeds were recruited from the quality control laboratory of Magapor SL, Spain. These samples came from 43 boar studs and resulted from diluting the ejaculates in commercial semen extenders. Evaluation of the semen sample characteristics (color, smell, pH, osmolality, concentration, motility of sperm cells, agglutination, acrosome integrity, short hypoosmotic swelling test, and abnormal forms) revealed that they met the international standards. The samples were also tested for the presence of aerobic bacterial contamination. In the present study, 14.73% (n = 263) of the semen samples were contaminated above 3 × 10(2) colony-forming units/mL with at least one type of bacteria. The Enterobacteriaceae family was by far the major contaminant, being present in 40.68% of the contaminated samples (n = 107). Bacterial strains of the Enterobacteriaceae family isolated from boar semen samples were in order of incidence (percentage of the contaminated samples): Serratia marcescens (12.55%), Klebsiella oxytoca (11.79%), Providencia stuartii (9.12%), Morganella morganii (3.80%), Proteus mirabilis (1.90%), and Escherichia coli (1.52%). We have seen that the presence in semen samples of S. marcescens, K. oxytoca, M. morganii, or P. mirabilis, but not P. stuartii or E. coli, was negatively associated with sperm motility (P < 0.05). The mean sperm concentration (P < 0.05), the mean percentage of spermatozoa with curled tails after the short hypoosmotic swelling test (P < 0.01), and the incidence of morphologically normal acrosomes (P < 0.05) were also lower in semen samples infected with M. morganii compared with uninfected ones. Moreover, P. mirabilis was negatively associated with the presence of abnormal forms. Thus, on the basis of the pathological effects that some of these strains may have on boar sperm quality, bacterial contamination should always be examined in semen samples prepared for artificial insemination. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. High prevalence of HIV p24 antigen among HIV antibody negative prospective blood donors in Ile-Ife, Nigeria.

    PubMed

    Japhet, Margaret Oluwatoyin; Adewumi, Moses Olubusuyi; Adesina, Olufisayo Adeyemi; Donbraye, Emmanuel

    2016-01-01

    Blood transfusion service centers in Nigeria screen donated blood for markers of HIV infection using antibody- (Ab) based rapid test and in some centers, positives are re-tested using Ab-based ELISA. Paucity of data exists on p24 antigen prevalence among HIV Ab-negative donors in Nigeria. This study aims at detecting HIV p24 antigen among prospective blood donors in Osun State, Nigeria. Prospective blood donors negative for HIV antibodies using Determine test kit were re-tested using BIORAD GENSCREEN Ultra Ag-Ab ELISA kit, a fourth-generation ELISA kit that detects HIV antibodies/p24 antigen. Of the 169 HIV Ab-negative prospective donors, 10 (5.9%) were positive for HIV p24 antigen and 70% (7/10) of them were in the age range 18-30 years. Results of this study show that blood transfusion is still one of the major routes of HIV transmission in Nigeria and a higher proportion is among youth. Inclusion of p24 antigen testing into the blood donor screening will help reduce transfusion associated HIV in Nigeria if Nucleic Acid Testing (NAT) of all blood donor samples is not affordable; also, HIV enlightenment programs tailored toward youth may help reduce this rate among donors since more young people donate blood in low/middle-income countries than in high-income countries.

  19. Effective assessment of egfr mutation status in bronchoalveolar lavage and pleural fluids by next-generation sequencing.

    PubMed

    Buttitta, Fiamma; Felicioni, Lara; Del Grammastro, Maela; Filice, Giampaolo; Di Lorito, Alessia; Malatesta, Sara; Viola, Patrizia; Centi, Irene; D'Antuono, Tommaso; Zappacosta, Roberta; Rosini, Sandra; Cuccurullo, Franco; Marchetti, Antonio

    2013-02-01

    The therapeutic choice for patients with lung adenocarcinoma depends on the presence of EGF receptor (EGFR) mutations. In many cases, only cytologic samples are available for molecular diagnosis. Bronchoalveolar lavage (BAL) and pleural fluid, which represent a considerable proportion of cytologic specimens, cannot always be used for molecular testing because of low rate of tumor cells. We tested the feasibility of EGFR mutation analysis on BAL and pleural fluid samples by next-generation sequencing (NGS), an innovative and extremely sensitive platform. The study was devised to extend the EGFR test to those patients who could not get it due to the paucity of biologic material. A series of 830 lung cytology specimens was used to select 48 samples (BAL and pleural fluid) from patients with EGFR mutations in resected tumors. These samples included 36 cases with 0.3% to 9% of neoplastic cells (series A) and 12 cases without evidence of tumor (series B). All samples were analyzed by Sanger sequencing and NGS on 454 Roche platform. A mean of 21,130 ± 2,370 sequences per sample were obtained by NGS. In series A, EGFR mutations were detected in 16% of cases by Sanger sequencing and in 81% of cases by NGS. Seventy-seven percent of cases found to be negative by Sanger sequencing showed mutations by NGS. In series B, all samples were negative for EGFR mutation by Sanger sequencing whereas 42% of them were positive by NGS. The very sensitive EGFR-NGS assay may open up to the possibility of specific treatments for patients otherwise doomed to re-biopsies or nontargeted therapies.

  20. Half a decade of mini-pool nucleic acid testing: Cost-effective way for improving blood safety in India

    PubMed Central

    Chandrashekar, Shivaram

    2014-01-01

    Background and Objectives: It is well established that Nucleic acid testing (NAT) reduces window phase of transfusion transmissible infections (TTI) and helps improve blood safety. NAT testing can be done individually or in pools. The objectives of this study were to determine the utility, feasibility and cost effectiveness of an in-house minipool-NAT(MP-NAT). Materials and Methods: Blood donors were screened by history, tested by ELISA and sero-negative samples were subjected to an in-house NAT by using reverse transcriptase-polymerase chain reaction (RT-PCR). Testing was done in mini-pools of size eight (8). Positive pools were repeated with individual samples. Results: During the study period of Oct 2005-Sept 2010 (5 years) all blood donors (n=53729) were screened by ELISA. Of which 469 (0.87%) were positive for HIV-1, HBV or HCV. Sero-negative samples (n=53260) were screened by in-house MP-NAT. HIV-NAT yield was 1/53260 (n=1) and HBV NAT yield (n=2) was 1/26630. Conclusion: NAT yield was lower than other India studies possibly due to the lower sero-reactivity amongst our donors. Nevertheless it intercepted 9 lives including the components prepared. The in-house assay met our objective of improving blood safety at nominal cost and showed that it is feasible to set up small molecular biology units in medium-large sized blood banks and deliver blood within 24-48 hours. The utility of NAT (NAT yield) will vary based on the donor population, the type of serological test used, the nature of kit employed and the sensitivity of NAT test used. The limitations of our in-house MP-NAT consisted of stringent sample preparation requirements, with labor and time involved. The benefits of our MP-NAT were that it acted as a second level of check for ELISA tests, was relatively inexpensive compared to ID-NAT and did not need sophisticated equipment. PMID:24678172

  1. Establishing diagnostic cut-off criteria for the COBAS AmpliPrep/COBAS TaqMan HIV-1 Qualitative test through validation against the Amplicor DNA test v1.5 for infant diagnosis using dried blood spots.

    PubMed

    Maritz, Jean; Preiser, Wolfgang; van Zyl, Gert U

    2012-02-01

    As antibody testing cannot confirm HIV-1 infection in children less than 18 months of age, diagnosis in these children depends on nucleic acid testing. The COBAS(®) AmpliPrep/COBAS(®) TaqMan(®) (CAP/CTM, Roche(®) Molecular Systems, Inc., Branchburg, NJ) HIV-1 Qualitative test is a total nucleic acid real-time PCR assay utilising whole EDTA blood or dried blood spots (DBS), which recently replaced the Roche(®) AMPLICOR(®) DNA test v1.5 (Amplicor) as the diagnostic HIV PCR assay in many South African laboratories. For the Amplicor assay, stringent diagnostic criteria were previously formulated for the local population, and a comparison reported the CAP/CTM's sensitivity at 99.7% and specificity at 100% for both sample types compared to these Amplicor criteria. To validate the assay prior to introduction in our laboratory and to define stringent diagnostic cut-off criteria. Whole EDTA blood samples from patients younger than 18 months sent for routine HIV-1 diagnosis were tested by Amplicor, and positive results were confirmed from DBS. CAP/CTM assays were subsequently performed from DBS. The CAP/CTM had a sensitivity of 98.8% and a specificity of 97.1%, but a positive predictive value (PPV) of only 78.7% compared to the Amplicor assay. Samples positive by CAP/CTM but negative by Amplicor displayed poor amplification curves compared to concordant positive samples. Upon re-testing those with sufficient material available by CAP/CTM, all showed negative results. The decreased PPV may either be due to false positive CAP/CTM results, or increased sensitivity compared to the Amplicor assay. Criteria were formulated for defining presumed false-positive results. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Screening of (-SEA) α-thalassaemia using an immunochromatographic strip assay for the ζ-globin chain in a population with a high prevalence and heterogeneity of haemoglobinopathies.

    PubMed

    Jomoui, Wittaya; Fucharoen, Goonnapa; Sanchaisuriya, Kanokwan; Fucharoen, Supan

    2017-01-01

    The presence of the ζ-globin chain is a good marker of (-- SEA ) α 0 -thalassaemia. We evaluated an immunochromatographic (IC) strip assay for ζ-globin in screening for (-- SEA ) α 0 -thalassaemia in a population with a high prevalence and heterogeneity of haemoglobinopathies. The study was carried out on 300 screen positive blood samples of Thai individuals. The IC strip assay for the ζ-globin chain was performed on all samples. The results were interpreted with thalassaemia genotyping using standard haemoglobin and DNA analyses. Several thalassaemia genotypes were noted. Among the 300 subjects investigated, 79 had a positive IC strip assay for ζ-globin and (-- SEA ) α 0 -thalassaemia was identified in 40 of them. No (-- SEA ) α 0 -thalassaemia was detected in the remaining 39 samples with a positive IC strip test result or in the 221 samples with a negative IC strip test result. Further DNA analysis identified α + -thalassaemia in 25 of the 39 (-- SEA ) α 0 -thalassaemia negative samples. Using this IC strip assay in combination with a conventional screening protocol for (-- SEA ) α 0 -thalassaemia could provide sensitivity and specificity of 100% and 90.4%, respectively. IC strip assay for ζ-globin is simple, rapid and does not require sophisticated equipment. Use of this test in addition to the existing screening protocol could detect potential (-- SEA ) α 0 -thalassaemia leading to a significant reduction in the workload of DNA analysis. This could be used in areas where haemoglobinopathies are prevalent and heterogeneous but molecular testing is not available. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. Validation and psychometric properties of the Alcohol Positive and Negative Affect Schedule: Are drinking emotions distinct from general emotions?

    PubMed

    Lac, Andrew; Donaldson, Candice D

    2018-02-01

    People vary in experiences of positive and negative emotions from consuming alcohol, but no validated measurement instrument exclusively devoted to assessing drinking emotions exists in the literature. The current research validated and evaluated the psychometric properties of an alcohol affect scale based on adjectives from the Positive and Negative Affect Schedule (PANAS) and tested the extent that emotions incurred from drinking were distinct from general trait-based emotions. Three studies tested independent samples of adult alcohol users. In Study 1 (N = 494), exploratory factor analyses of the Alcohol PANAS revealed that both the 20-item model and the 9-parcel model (represented by similar mood content) supported the 2-factor dimensionality of alcohol positive and negative affect. In Study 2 (N = 302), confirmatory factor analyses corroborated the measurement structure of alcohol positive and negative affect, and both constructs evidenced statistical independence from general positive and negative affect. In Study 3 (N = 452), alcohol positive and negative affect exhibited discriminant, convergent, and criterion validity with established alcohol scales. Incremental validity tests demonstrated that alcohol positive and negative affect uniquely contributed (beyond general positive and negative affect) to alcohol expectancies, use, and problems. Findings support that alcohol emotions are conceptually distinct from trait emotions, and underscore the necessity of an assessment instrument tailored to the former to examine associations with alcohol beliefs and behaviors. The Alcohol PANAS confers theoretical and practical applications to understand the emotional consequences of drinking. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  4. Glove permeation by semiconductor processing mixtures containing glycol-ether derivatives.

    PubMed

    Zellers, E T; Ke, H Q; Smigiel, D; Sulewski, R; Patrash, S J; Han, M W; Zhang, G Z

    1992-02-01

    Results of permeation tests of several glove materials challenged with semiconductor processing formulations containing glycolether derivatives are described. Commercial glove samples of nitrile rubber (Edmont), natural rubber (Edmont and Baxter), butyl rubber (North), PVC Baxter), a natural rubber/neoprene/nitrile blend (Pioneer), and a natural rubber/neoprene blend (Playtex) were tested according to the ASTM F739-85 permeation test method (open-loop configuration). The liquid formulations examined included a positive photoresist thinner containing 2-ethoxyethyl acetate (2-EEA), n-butyl acetate, and xylene; a positive photoresist containing 2-EEA, n-butyl acetate, xylene, polymer resins, and photoactive compounds; a negative photoresist containing 2-methoxyethanol (2-ME), xylene, and cyclized poly(isoprene); and pure 2-methoxyethyl acetate (2-MEA), which is the solvent used in a commercial electron-beam resist. With the exception of the negative photoresist, butyl rubber provided the highest level of protection against the solvent mixtures tested, with no breakthrough observed after 4 hr of continuous exposure at 25 degrees C. Nitrile rubber provided the highest level of protection against the negative photoresist and reasonably good protection against initial exposure to the other solvent mixtures. Gloves consisting of natural rubber or natural rubber blends provided less protection against the mixtures than either nitrile or butyl rubber. For most of the glove samples, permeation of the glycol-ether derivatives contained in the mixtures was faster than that predicted from the permeation of the pure solvents. Increasing the exposure temperature from 25 to 37 degrees C did not significantly affect the performance of the butyl rubber glove. For the other gloves, however, exposures at 37 degrees C resulted in decreases in breakthrough times of 25-75% and increases in steady-state permeation rates of 80-457% relative to values obtained at 25 degrees C. Repeated exposure of nitrile rubber samples resulted in shorter breakthrough times for all mixture components. In fact, exposure for as little as one-half of the nominal breakthrough time followed by air drying overnight resulted in measurable quantities of one or more of the component solvents at the inner surface of the gloves at the beginning of the next exposure. This effect was not observed with the butyl rubber samples. With the exception of the negative photoresist, heating previously exposed nitrile rubber samples at 70 degrees C for 20 hr prior to retesting reduced or eliminated the effects of residual solvents, permitting reuse of the gloves. The use of thin PVC or natural rubber gloves adjacent to the nitrile gloves provided moderate increases in permeation resistance.(ABSTRACT TRUNCATED AT 400 WORDS)

  5. Multiplex polymerase chain reaction test for the diagnosis of acute viral hepatitis A.

    PubMed

    Heo, Nae-Yun; Lim, Young-Suk; An, Jihyun; Ko, Sun-Young; Oh, Heung-Bum

    2012-12-01

    The early diagnosis of acute hepatitis A (AHA) is hindered because serum IgM against hepatitis A virus (HAV) can yield false-negative results during the window period. This study evaluated the diagnostic accuracy of a polymerase chain reaction (PCR) kit for HAV RNA for the diagnosis of AHA. Samples were collected from 136 patients with acute severe hepatitis at their admission to Asan Medical Center between June 2010 and July 2010. Samples were analyzed for serum IgM anti-HAV using an immunoassay test and for qualitative HAV RNA using the Magicplex HepaTrio PCR test kit. The diagnostic accuracies of these methods were tested on the basis of clinical and laboratory diagnoses of AHA. The concordance rate and kappa value between IgM anti-HAV and HAV RNA PCR were 88.2% and 0.707, respectively. For the diagnosis of AHA, the sensitivity and specificity of IgM anti-HAV were 90.7% and 100%, respectively, when an "equivocal" result was regarded as positive; and 79.1% and 100%, respectively, when an "equivocal" result was regarded as negative. The sensitivity and specificity of HAV RNA PCR were 81.4% and 100%, respectively. All four patients with negative IgM anti-HAV and positive HAV RNA PCR results and all four patients with equivocal IgM anti-HAV RNA and positive HAV RNA PCR results were eventually diagnosed with AHA. The qualitative HAV RNA PCR test has an equivalent diagnostic accuracy for AHA compared to IgM anti-HAV and may be more sensitive during the window period.

  6. Serodiagnosis of whooping cough in Belgium: results of the National Reference Centre for Bordetella pertussis anno 2013.

    PubMed

    Duterme, Sophie; Vanhoof, Raymond; Vanderpas, Jean; Pierard, Denis; Huygen, Kris

    2016-04-01

    Report on the pitfalls of serodiagnosis of pertussis in Belgium for 2013 by the NRC Bordetella. Determine cases of acute infection using an anti-pertussis toxin (PT) IgG antibody ELISA. A total of 2471 serum samples were received. Clinical information on the duration of cough (at moment of blood sampling) is essential for a reliable interpretation of the results. In order to avoid false negative results, 213 samples for which this information was lacking were not tested. For a total of 2179 patients tested, 520 (23.9%) had antibody levels indicative of an acute infection, 261 (12%) samples were diagnosed as positive (indicative of a pertussis infection or vaccination during the last year), 143 (6.7%) samples were classified as doubtful and 752 (34,5%) (35.5%) were diagnosed as negative. The serodiagnosis of pertussis has limited value for the early diagnosis of the disease and PCR analysis on nasopharyngeal swabs is the method of choice during the first 2 weeks and always for young children <1 year old. For sera collected during the first 2 weeks with anti-PT levels below the threshold for acute infection, a second sample collected 2-3 weeks later is needed a definitive diagnosis. For 503 (23.0%) early samples, a second serum sample was requested but not provided. For 85 patients, for whom a second sample was received, 12.9% were eventually diagnosed as having an acute infection. In order to generate reliable serodiagnostic results for pertussis, serum samples should preferentially be collected 3 weeks after onset of symptoms.

  7. Karolinska Scales of Personality, cognition and psychotic symptoms in patients with schizophrenia and healthy controls.

    PubMed

    Nilsson, Björn Mikael; Holm, Gunnar; Ekselius, Lisa

    2016-01-01

    Studies on both personality dimensions and cognition in schizophrenia are scarce. The objective of the present study was to examine personality traits and the relation to cognitive function and psychotic symptoms in a sample of patients with schizophrenia and healthy controls. In total 23 patients with schizophrenia and 14 controls were assessed with the Karolinska Scales of Personality (KSP). A broad cognitive test programme was used, including the Wechsler Adult Intelligence Scales, the Finger-Tapping Test, the Trail Making Test, the Verbal Fluency Test, the Benton Visual Retention Test, the Wisconsin Card Sorting Test and Rey Auditory Verbal Learning Test . Compared with controls, the patients exhibited prominent elevations on KSP scales measuring anxiety proneness and neuroticism (P = 0.000005-0.0001), on the Detachment scale (P < 0.00009) and lower value on the Socialization scale (P < 0.0002). The patients also scored higher on the Inhibition of Aggression, Suspicion, Guilt and Irritability scales (P = 0.002-0.03) while the remaining five scales did not differ between patients and controls. KSP anxiety-related scales correlated with the Positive and Negative Symptoms Scale (PANSS) general psychopathology subscale. Cognitive test results were uniformly lower in the patient group and correlated with PANSS negative symptoms subscale. There was no association between KSP scale scores and PANSS positive or negative symptoms. The patients revealed a highly discriminative KSP test profile with elevated scores in neuroticism- and psychoticism-related scales as compared to controls. Results support previous findings utilizing other personality inventories in patients with schizophrenia. Cognitive test performance correlated inversely with negative symptoms.

  8. Comparison of a modified shell vial culture procedure with conventional mouse inoculation for rabies virus isolation.

    PubMed

    Ribas Antúnez, María de los Angeles; Girón, Blanca; Monsalvez, Iraima; Morier, Luis; Acosta, Gretel; Tejero, Yahisel; Cordero, Yanislet; Piedra, Dainelyd

    2013-04-01

    Rabies is a neurotropic disease that is often lethal. The early diagnosis of rabies infection is important and requires methods that allow for the isolation of the virus from animals and humans. The present study compared a modified shell vial (MSV) procedure using 24-well tissue culture plates with the mouse inoculation test (MIT), which is considered the gold standard for rabies virus isolation. Thirty brain samples (25 positive and 5 negative by the fluorescent antibody test) obtained from different animal species at the National Institute of Hygiene Rafael Rangel in Caracas, Venezuela, were studied by the MIT and MSV assays. Nine samples (36%) were positive at 24 h, 10 (40%) were positive at 48 h and six (24%) were positive at 72 h by the MSV assay. With the MIT assay, 76% were positive at six days post inoculation and 12% were positive at 12 and 18 days post inoculation. One sample that was negative according to the MSV assay was positive with MIT on the 12th day. The MSV procedure exhibited a sensitivity of 96.2%, a specificity of 100%, a positive predictive value of 100% and a negative predictive value 80%. This procedure allowed for rapid rabies virus detection. MIT can be employed as an alternative method in laboratories without tissue culture facilities.

  9. Testing the influence of external and internal cues on smoking motivation using a community sample.

    PubMed

    Litvin, Erika B; Brandon, Thomas H

    2010-02-01

    Exposing smokers to either external cues (e.g., pictures of cigarettes) or internal cues (e.g., negative affect induction) can induce urge to smoke and other behavioral and physiological responses. However, little is known about whether the two types of cues interact when presented in close proximity, as is likely the case in the real word. Additionally, potential moderators of cue reactivity have rarely been examined. Finally, few cue-reactivity studies have used representative samples of smokers. In a randomized 2 x 2 crossed factorial between-subjects design, the current study tested the effects of a negative affect cue intended to produce anxiety (speech preparation task) and an external smoking cue on urge and behavioral reactivity in a community sample of adult smokers (N = 175), and whether trait impulsivity moderated the effects. Both types of cues produced main effects on urges to smoke, despite the speech task failing to increase anxiety significantly. The speech task increased smoking urge related to anticipation of negative affect relief, whereas the external smoking cues increased urges related to anticipation of pleasure; however, the cues did not interact. Impulsivity measures predicted urge and other smoking-related variables, but did not moderate cue-reactivity. Results suggest independent rather than synergistic effects of these contributors to smoking motivation. (PsycINFO Database Record (c) 2010 APA, all rights reserved).

  10. Urdu translation and validation of shorter version of Positive Affect and Negative Affect Schedule (PANAS) on Pakistani bank employees.

    PubMed

    Akhter, Noreen

    2017-10-01

    To translate, adapt and validate shorter version of positive affect and negative affect scale on Pakistani corporate employees. This cross-sectional study was conducted in the twin cities of Islamabad and Rawalpindi from October 2014 to December 2015. The study was completed into two independent parts. In part one, the scale was translated by forward translation. Then it was pilot-tested and administered on customer services employees from commercial banks and the telecommunication sector. Data of the pilot study was analysed by using exploratory factor analysis to extract the initial factor of positive affect and negative affect scale. Part two comprised the main study. Commercial bank employees were included in the sample using convenient sampling technique. Data of the main study was analysed using confirmatory factor analysis in order to establish construct validity of positive affect and negative affect scale. There were145 participants in the first part of the study and 495 in the second. Results of confirmatory factor analysis confirmed the two-factor structure of positive affect and negative affect scale suggesting that the scale has two distinct domains, i.e. positive affect and negative affect. The shorter version of positive affect and negative affect scale was found to be a valid and reliable measure.

  11. Typhoid fever in a Tertiary Hospital in Nigeria: Another look at the Widal agglutination test as a preferred option for diagnosis.

    PubMed

    Enabulele, Osahon; Awunor, Simeon Nyemike

    2016-01-01

    Single Widal agglutination test rather than blood culture, is commonly employed to diagnose typhoid fever in Nigeria. We took another look at the Widal agglutination test as a preferred option for diagnosis of typhoid fever by determining the specificity and sensitivity of Widal agglutination test in febrile adult patients. Two hundred and seventy-one blood samples from consecutive adults (>18 years) with febrile illness attending the General Practice Clinic of the University of Benin Teaching Hospital were tested using the Widal agglutination test, blood culture, and malaria parasite test on each sample to establish the diagnosis of typhoid fever. Of the 271 blood samples 124 (45.76%) were positive following a Widal agglutination test, 60 (22.10%) blood samples grew Salmonella organisms on blood culture while 55 (20.29%) blood samples showed a co-infection of typhoid fever and malaria. A sensitivity of 35%, specificity of 51%, positive predictive value of 17%, and a negative predictive value of 73% were observed for Widal agglutination test as a diagnostic modality for typhoid fever infection. A single Widal agglutination test is not a valid diagnostic option for typhoid fever while co-infection with malaria parasite is the preponderant microbiological finding in typhoid fever infections. The severity of malaria parasitemia is associated with positive titers on Widal test.

  12. Typhoid fever in a Tertiary Hospital in Nigeria: Another look at the Widal agglutination test as a preferred option for diagnosis

    PubMed Central

    Enabulele, Osahon; Awunor, Simeon Nyemike

    2016-01-01

    Background: Single Widal agglutination test rather than blood culture, is commonly employed to diagnose typhoid fever in Nigeria. We took another look at the Widal agglutination test as a preferred option for diagnosis of typhoid fever by determining the specificity and sensitivity of Widal agglutination test in febrile adult patients. Materials and Methods: Two hundred and seventy-one blood samples from consecutive adults (>18 years) with febrile illness attending the General Practice Clinic of the University of Benin Teaching Hospital were tested using the Widal agglutination test, blood culture, and malaria parasite test on each sample to establish the diagnosis of typhoid fever. Results: Of the 271 blood samples 124 (45.76%) were positive following a Widal agglutination test, 60 (22.10%) blood samples grew Salmonella organisms on blood culture while 55 (20.29%) blood samples showed a co-infection of typhoid fever and malaria. A sensitivity of 35%, specificity of 51%, positive predictive value of 17%, and a negative predictive value of 73% were observed for Widal agglutination test as a diagnostic modality for typhoid fever infection. Conclusion: A single Widal agglutination test is not a valid diagnostic option for typhoid fever while co-infection with malaria parasite is the preponderant microbiological finding in typhoid fever infections. The severity of malaria parasitemia is associated with positive titers on Widal test. PMID:27397952

  13. Psychometric Properties of the Chinese Version of the Brief Borderline Symptom List in Undergraduate Students and Clinical Patients.

    PubMed

    Yang, Huihui; Lei, Xiaoxia; Zhong, Mingtian; Zhou, Qi; Ling, Yu; Jungkunz, Martin; Yi, Jinyao

    2018-01-01

    The brief version of the Borderline Symptom List (BSL-23) is a self-rated scale developed from the initial 95-item version of Borderline Symptom List (BSL-95). The current study aimed to evaluate the psychometric properties of the Chinese version of the BSL-23. A total of 570 undergraduate students and 323 clinical patients completed the BSL-23, the borderline subscale of the Personality Diagnostic Questionnaire (PDQ-4+), the Center for Epidemiologic Studies Depression Scale (CES-D), the Barratt Impulsiveness Scale, 11th version (BIS-11), the Childhood Trauma Questionnaire (CTQ) and the Attachment Style Questionnaire (ASQ). A Confirmatory Factor Analysis (CFA) was conducted to test the one-factor structure of the BSL-23. Cronbach's alpha, Omega coefficient, Split-Half coefficient, Mean Inter-Item Correlation (M IC ) and test-retest reliability were also measured. The correlations between the BSL-23 and other psychological variables were used to assess criterion-related validity and convergent validity. Participants who scored ≥ 5 on the borderline subscale of the PDQ-4+ were placed into the borderline personality disorder (BPD) screening-positive group, while the others were placed into the screening-negative group. Independent sample t -tests were performed to examine the differences in BSL-23 scores between the BPD screening-positive group and the BPD screening-negative group. The CFA results supported the one-factor structure of the BSL-23 in both samples. The internal consistency was high both in the undergraduate sample (Cronbach's α = 0.93, Omega = 0.95, Split-Half coefficient = 0.89, M IC = 0.38) and the clinical sample (Cronbach's α = 0.97, Omega = 0.97, Split-Half coefficient = 0.96, M IC = 0.56). The test-retest reliability within 2 weeks was 0.62. The BSL-23 displayed moderate to high correlations with the PDQ-4+-Borderline subscale, the CES-D, the BIS-11, the CTQ and the ASQ ( r = 0.35 - 0.70). In addition, the BSL-23 discriminated between the BPD screening-positive and the BPD screening-negative participants, and also between the patient sample and undergraduate sample. In conclusion, the Chinese version of the BSL-23 has satisfactory psychometric properties to assess BPD symptoms.

  14. Evaluation of the black light test for screening aflatoxin-contaminated maize in the Brazilian food industry.

    PubMed

    Gloria, E M; Fonseca, H; Calori-Domingues, M A; Souza, I M

    1998-01-01

    The results of the black light test for aflatoxin-contaminated maize carried out in a large food factory in the State of São Paulo was evaluated against bi-directional thin layer chromatography (TLC) analysis for 286 samples of maize. All 286 samples were accepted by the black light test (< 7 fluorescent points), however, the results from TLC analysis showed that 96 samples were contaminated and 14 showed aflatoxin B1 contamination levels higher than 20 micrograms/kg. There were 14 false negative results and no false positives and out of the 14 samples, six did not show visible fluorescent points. If the rejection criterion of one or more fluorescent points were applied, the six samples would be accepted by the black light test. But, in this case, 95 samples would be rejected and 87 results would be false positives because they did not have contamination levels over 20 micrograms/kg which is the acceptance limit of the black light test. The results indicate that the black light test, as utilized by this factory, was not able to indicate lots with possible contamination and the black light test, as recommended in the literature, would produce a high number of false positives. It is necessary to make more studies on the use of black light as a screening test for possible aflatoxin B1-contaminated maize.

  15. An international inter-laboratory ring trial to evaluate a real-time PCR assay for the detection of bovine herpesvirus 1 in extended bovine semen.

    PubMed

    Wang, Jianning; O'Keefe, Joseph; Orr, Della; Loth, Leo; Banks, Malcolm; Wakeley, Philip; West, Donna; Card, Roderick; Ibata, Georgina; Van Maanen, Kees; Thoren, Peter; Isaksson, Mats; Kerkhofs, Pierre

    2008-01-01

    Six laboratories participated in a ring trial to evaluate the reliability of a real-time PCR assay for the detection of bovine herpesvirus 1 (BoHV-1) from extended bovine semen. Sets of coded samples were prepared and distributed to each of the laboratories. The sample panel contained semen from naturally and artificially infected bulls, serial dilutions of positive semen with negative semen, semen from uninfected seronegative bulls, negative semen spiked with virus, as well as serial dilutions of reference virus. The samples were tested using a previously validated real-time PCR assay for the detection of BoHV-1 in each participating laboratory. The PCR tests were conducted with four different real-time PCR amplification platforms, including RotorGene 3000, Stratagene MX 3000/4000, ABI 7900, and Roche LightCycler 2.0. Virus isolation using one set of samples was performed in one laboratory. The results of the laboratories were compared with one another, and with those of virus isolation. It was found that the sensitivity and specificity of the real-time PCR test was greater than those of virus isolation (82.7% versus 53.6% and 93.6% versus 84.6%, respectively). A high level of agreement on PCR testing results between the laboratories was achieved (kappa value 0.59-0.95). The results of this study indicate that the real-time PCR assay is suitable for the detection of BoHV-1 in extended semen, and would be a good substitute for the slow and laborious virus isolation, for the screening testing at artificial insemination centres and for international trade.

  16. Clinical evaluation of the Abbott RealTime MTB Assay for direct detection of Mycobacterium tuberculosis-complex from respiratory and non-respiratory samples.

    PubMed

    Hinić, Vladimira; Feuz, Kinga; Turan, Selda; Berini, Andrea; Frei, Reno; Pfeifer, Karin; Goldenberger, Daniel

    2017-05-01

    Rapid and reliable diagnosis is crucial for correct management of tuberculosis. The Abbott RealTime MTB Assay represents a novel qualitative real-time PCR assay for direct detection of M. tuberculosis-complex (MTB) DNA from respiratory samples. The test targets two highly conserved sequences, the multi-copy insertion element IS6110 and the protein antigen B (PAB) gene of MTB, allowing even the detection of IS6610-deficient strains. We evaluated this commercial diagnostic test by analyzing 200 respiratory and, for the first time, 87 non-respiratory clinical specimens from our tertiary care institution and compared its results to our IS6110-based in-house real-time PCR for MTB as well as MTB culture. Overall sensitivity for Abbott RealTime MTB was 100% (19/19) in smear positive and 87.5% (7/8) in smear negative specimens, while the specificity of the assay was 100% (260/260). For both non-respiratory smear positive and smear negative specimens Abbott RealTime MTB tests showed 100% (8/8) sensitivity and 100% (8/8) specificity. Cycle threshold (Ct) value analysis of 16 MTB positive samples showed a slightly higher Ct value of the Abbott RealTime MTB test compared to our in-house MTB assay (mean delta Ct = 2.55). In conclusion, the performance of the new Abbott RealTime MTB Assay was highly similar to culture and in-house MTB PCR. We document successful analysis of 87 non-respiratory samples with the highly automated Abbott RealTime MTB test with no inhibition observed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Symptom structure and severity: a comparison of responses to the positive and negative syndrome scale (PANSS) between patients with PTSD or schizophrenia.

    PubMed

    Stefanovics, Elina A; Krystal, John H; Rosenheck, Robert A

    2014-05-01

    To describe and compare the structure and relative severity of symptoms in clinical trial patients diagnosed with Post Traumatic Stress Disorder (PTSD) or schizophrenia using the Positive and Negative Syndrome Scale (PANSS), developed originally to evaluate symptoms of schizophrenia. This secondary data analysis used baseline PANSS symptom ratings (n=267) from a six-month multicenter randomized placebo-controlled trial of adjunctive risperidone in patients with chronic military-related PTSD. First, using a split-half design, Exploratory Factor Analysis (EFA) was employed to identify independent factors which were then compared to published factor structures for schizophrenia. Next, Confirmatory Factor Analysis (CFA) was applied to the second half of the sample to compare the results of the EFA and published factor structures. Finally, T-tests were used to compare the severity of factor scores between the PTSD sample and the baseline PANSS ratings from the Clinical Antipsychotic Trial for Intervention Effectiveness (CATIE) schizophrenia sample (n=1460). EFA suggested five factors similar to those identified in a summary of 29 schizophrenia studies by Wallwork (Schizophrenia Research, 137:246-250). CFA showed that the five factor Wallwork model fit the data better than the EFA, although both had relatively high goodness of fit. T-tests showed that the PTSD sample had more severe symptoms on the Depressive factor, and the schizophrenia sample on the Positive, Negative, and Disorganized factors, with no significant difference on the Excited factor. Veterans with PTSD had similar symptom structure to patients with schizophrenia on the PANSS, but were less symptomatic on psychosis-related factors and more symptomatic on depression. Dimensional symptom factors can be virtually the same across diagnoses. Published by Elsevier Inc.

  18. Severe reactions from roe without concomitant fish allergy.

    PubMed

    Mäkinen-Kiljunen, Soili; Kiistala, Raija; Varjonen, Elina

    2003-10-01

    Although fish allergy is common, no studies have been published on allergy to fish roe. To describe 2 cases of IgE-mediated allergy to 2 roe species. Two patients, one with local symptoms and the other with anaphylaxis following ingestion of roe, underwent skin prick testing (SPT) with 2 roe species, whitefish roe (WFR) and rainbow trout roe (RTR). Serum samples were taken for IgE measurement and immunoblotting to identify roe allergens. Inhibition studies were performed to scrutinize the cross-reactivity between the roes and to fish. The results of the SPTs with the roes were clearly positive in both patients but negative in control persons. The results of SPTs to all other foods were negative. Roe-specific IgE levels were elevated in the serum samples of both patients. Immunoblotting revealed different IgE-binding patterns of the extracts and different inhibition profiles with the serum samples. In WFR blotting, both serum samples detected a heavy IgE-binding band at approximately 20 kDa, which was not inhibited with fish. Cross-reactivity between the roes was demonstrated in the patient with local symptoms from RTR but not in the patient with anaphylaxis from WFR. The first serum sample also detected several IgE-binding bands in the RTR blot, the most intensive at 21 to 23 kDa and 30 kDa, which were partially inhibited by WFR and more completely with fish. The anaphylaxis patient did not detect allergens in the RTR blot. After the investigation, the patients have remained symptom free and able to consume all kinds of fish without problems. IgE-mediated allergy to roe is possible without concomitant fish allergy. Roe allergy should be explored in patients who test negative to fish but are suspected of having seafood-related allergy.

  19. Comparison between Roche and Xpert in HIV-1 RNA quantitation: A high concordance between the two techniques except for a CRF02_AG subtype variant with high viral load titters detected by Roche but undetected by Xpert.

    PubMed

    Avidor, Boaz; Matus, Natalia; Girshengorn, Shirley; Achsanov, Svetlana; Gielman, Simona; Zeldis, Irene; Schweitzer, Inbal; Adler, Amos; Turner, Dan

    2017-08-01

    HIV-1 viral load (VL) testing is important to predict viral progression and to monitor the response to antiretroviral therapy. New HIV-1 VL tests are continuously introduced to the market. Their performance is usually compared to Abbott and/or Roche HIV-1 VL assays, as reference. The Xpert HIV-1 VL test was recently introduced, but its performance compared to Roche has not been sufficiently studied. To compare the Xpert assay with Roche and to assess its use in the HIV clinical laboratory. A total of 383 plasma samples of HIV-1 infected patients previously tested by Roche, were retrospectively tested by Xpert to determine concordance between the two assays. Samples included a diversity of HIV-1 subtypes and a wide range of VLs. There was a high concordance between the two assays, except for a CRF02_AG subtype variant with high VL titters, that was detected by Roche but undetected by Xpert. The 5' long terminal repeat gene region of this virus, targeted by the Xpert assay, was amplified and sequenced. A 25 nucleotide insert was identified, but was unmatched to any known sequences of HIV-1. This particular insert, however could not explain the false-negativity by the Xpert assay. This study underlines the challenge to routine VL testing due to the high genetic diversity of HIV-1. Clinicians should, therefore be advised that a negative VL in cases where the clinical picture does not match the laboratory report, might in fact be, a false-negative result of the VL assay. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Development of a fluorescent antibody virus neutralisation test (FAVN test) for the quantitation of rabies-neutralising antibody.

    PubMed

    Cliquet, F; Aubert, M; Sagné, L

    1998-03-01

    A microtest named the FAVN test (fluorescent antibody virus neutralisation test), which is an adaptation of the original rapid fluorescent focus inhibition test (RFFIT) has been developed and evaluated. One hundred percent specificity was estimated using 414 sera from dogs sampled in rabies-free areas or from non-vaccinated animals. The accuracy as determined by the agreement between observed and expected values using sera of known titres was satisfactory. Serum samples from unvaccinated and vaccinated dogs (using sera with titres near 0.5 IU/ml) were assayed for rabies antibody by the FAVN test, the RFFIT and the mouse neutralisation test (MNT): comparative results obtained on the same sera with the three tests showed good agreement. Furthermore, distinguishing negative sera from positive sera with low titres is much easier with the FAVN test than with the RFFIT.

  1. Imperfect pathogen detection from non-invasive skin swabs biases disease inference

    USGS Publications Warehouse

    DiRenzo, Graziella V.; Grant, Evan H. Campbell; Longo, Ana; Che-Castaldo, Christian; Zamudio, Kelly R.; Lips, Karen

    2018-01-01

    1. Conservation managers rely on accurate estimates of disease parameters, such as pathogen prevalence and infection intensity, to assess disease status of a host population. However, these disease metrics may be biased if low-level infection intensities are missed by sampling methods or laboratory diagnostic tests. These false negatives underestimate pathogen prevalence and overestimate mean infection intensity of infected individuals. 2. Our objectives were two-fold. First, we quantified false negative error rates of Batrachochytrium dendrobatidis on non-invasive skin swabs collected from an amphibian community in El Copé, Panama. We swabbed amphibians twice in sequence, and we used a recently developed hierarchical Bayesian estimator to assess disease status of the population. Second, we developed a novel hierarchical Bayesian model to simultaneously account for imperfect pathogen detection from field sampling and laboratory diagnostic testing. We evaluated the performance of the model using simulations and varying sampling design to quantify the magnitude of bias in estimates of pathogen prevalence and infection intensity. 3. We show that Bd detection probability from skin swabs was related to host infection intensity, where Bd infections < 10 zoospores have < 95% probability of being detected. If imperfect Bd detection was not considered, then Bd prevalence was underestimated by as much as 16%. In the Bd-amphibian system, this indicates a need to correct for imperfect pathogen detection caused by skin swabs in persisting host communities with low-level infections. More generally, our results have implications for study designs in other disease systems, particularly those with similar objectives, biology, and sampling decisions. 4. Uncertainty in pathogen detection is an inherent property of most sampling protocols and diagnostic tests, where the magnitude of bias depends on the study system, type of infection, and false negative error rates. Given that it may be difficult to know this information in advance, we advocate that the most cautious approach is to assume all errors are possible and to accommodate them by adjusting sampling designs. The modeling framework presented here improves the accuracy in estimating pathogen prevalence and infection intensity.

  2. Survey of South African fruit juices using a fast screening HILIC-MS method.

    PubMed

    Stander, Marietjie A; Kühn, Wernich; Hiten, Nicholas F

    2013-01-01

    Adulteration of fruit juices--by the addition of sugar or other less expensive fruit juices as well as preservatives, artificial sweeteners and colours--was tested for by using a developed screening method. The method employs hydrophilic interaction liquid chromatography-mass spectrometry (HILIC-MS) using electrospray ionisation in the negative mode and ultraviolet light detection. Different fruit juices can be differentiated by the content of marker compounds like sorbitol, certain phenolic molecules and their saccharide profile. This method was used to test 46 fruit juice samples from the retail market as well as 12 control samples. The study focused on the main types of fruit juices consumed on the South African market including apple, orange, grape and blends of these juices with other fruits like mango, pear and guava. Overall, the 46 samples tested mostly agreed with label claims. One grape juice sample was adulterated, probably with apple juice. Natamycin above the legal limits was found in two samples. In addition, two samples contained natamycin and one sample benzoate without it being indicated on the label. The method is well suited as a quick screening method for fruit juice adulteration and if used routinely would reduce fruit juice adulteration without the cost of the current array of tests needed for authenticity testing.

  3. External quality assessment for KRAS testing is needed: setup of a European program and report of the first joined regional quality assessment rounds.

    PubMed

    Bellon, Ellen; Ligtenberg, Marjolijn J L; Tejpar, Sabine; Cox, Karen; de Hertogh, Gert; de Stricker, Karin; Edsjö, Anders; Gorgoulis, Vassilis; Höfler, Gerald; Jung, Andreas; Kotsinas, Athanassios; Laurent-Puig, Pierre; López-Ríos, Fernando; Hansen, Tine Plato; Rouleau, Etienne; Vandenberghe, Peter; van Krieken, Johan J M; Dequeker, Elisabeth

    2011-01-01

    The use of epidermal growth factor receptor-targeting antibodies in metastatic colorectal cancer has been restricted to patients with wild-type KRAS tumors by the European Medicines Agency since 2008, based on data showing a lack of efficacy and potential harm in patients with mutant KRAS tumors. In an effort to ensure optimal, uniform, and reliable community-based KRAS testing throughout Europe, a KRAS external quality assessment (EQA) scheme was set up. The first large assessment round included 59 laboratories from eight different European countries. For each country, one regional scheme organizer prepared and distributed the samples for the participants of their own country. The samples included unstained sections of 10 invasive colorectal carcinomas with known KRAS mutation status. The samples were centrally validated by one of two reference laboratories. The laboratories were allowed to use their own preferred method for histological evaluation, DNA isolation, and mutation analysis. In this study, we analyze the setup of the KRAS scheme. We analyzed the advantages and disadvantages of the regional scheme organization by analyzing the outcome of genotyping results, analysis of tumor percentage, and written reports. We conclude that only 70% of laboratories correctly identified the KRAS mutational status in all samples. Both the false-positive and false-negative results observed negatively affect patient care. Reports of the KRAS test results often lacked essential information. We aim to further expand this program to more laboratories to provide a robust estimate of the quality of KRAS testing in Europe, and provide the basis for remedial measures and harmonization.

  4. Detection and Species Determination of Malaria Parasites by PCR: Comparison with Microscopy and with ParaSight-F and ICT Malaria Pf Tests in a Clinical Environment

    PubMed Central

    Tham, Jill M.; Lee, Szu Hee; Tan, Theresa M. C.; Ting, Robert C. Y.; Kara, Ursula A. K.

    1999-01-01

    A rapid procedure for the diagnosis of malaria infections directly from dried blood spots by PCR amplification was evaluated with samples from 52 patients. Plasmodium infections were identified with a genus-specific primer set, and species differentiation between Plasmodium falciparum and Plasmodium vivax was analyzed by multiplex PCR. The PCR test with any of the three primer sets was able to detect as few as four parasites per microliter by gel electrophoresis or by nonisotopic paper hybridization chromatography. The diagnoses obtained by PCR correlated closely with those obtained by Giemsa staining except for two samples observed to have mixed P. falciparum-P. vivax infections. These were initially missed by microscopic analysis. In comparison with antigen-capture assays for P. falciparum, the PCR assays were able to detect three infections that were missed by the ParaSight-F test. The PCR test was negative for nine ParaSight-F-positive samples and one ICT Malaria Pf-positive sample, and these were confirmed to be false-positive results. The PCR thus gave no false-negative or false-positive results. Patients undergoing antimalarial therapy were also monitored by the PCR assay. Four of seven patients who were PCR positive for P. vivax at the time of discharge were later readmitted to the hospital with a recurrence of P. vivax infection. We would like to propose that PCR is a sensitive and easy method that can serve as a useful addition to microscopy for the diagnosis and the clinical monitoring of treatment of malaria. PMID:10203469

  5. Optimization and validation of CEDIA drugs of abuse immunoassay tests in serum on Hitachi 912.

    PubMed

    Kirschbaum, Katrin M; Musshoff, Frank; Schmithausen, Ricarda; Stockhausen, Sarah; Madea, Burkhard

    2011-10-10

    Due to sensitive limits of detection of chromatographic methods and low limit values regarding the screening of drugs under the terms of impairment in safe driving (§ 24a StVG, Street Traffic Law in Germany), preliminary immunoassay (IA) tests should be able to detect also low concentrations of legal and illegal drugs in serum in forensic cases. False-negatives should be avoided, the rate of false-positive samples should be low due to cost and time. An optimization of IA cutoff values and a validation of the assay is required for each laboratory. In a retrospective study results for serum samples containing amphetamine, methylenedioxy derivatives, cannabinoids, benzodiazepines, cocaine (metabolites), methadone and opiates obtained with CEDIA drugs of abuse reagents on a Hitachi 912 autoanalyzer were compared with quantitative results of chromatographic methods (gas or liquid chromatography coupled with mass spectrometry (GC/MS or LC/MS)). Firstly sensitivity, specificity, positive and negative predictive values and overall misclassification rates were evaluated by contingency tables and compared to ROC-analyses and Youden-Indices. Secondly ideal cutoffs were statistically calculated on the basis of sensitivity and specificity as decisive statistical criteria with focus on a high sensitivity (low rates of false-negatives), i.e. using the Youden-Index. Immunoassay (IA) and confirmatory results were available for 3014 blood samples. Sensitivity was 90% or more for nearly all analytes: amphetamines (IA cutoff 9.5 ng/ml), methylenedioxy derivatives (IA cutoff 5.5 ng/ml), cannabinoids (IA cutoff 14.5 ng/ml), benzodiazepines (IA cutoff >0 ng/ml). Test of opiates showed a sensitivity of 86% for a IA cutoff value of >0 ng/ml. Values for specificity ranged between 33% (methadone, IA cutoff 10 ng/ml) and 90% (cocaine, IA cutoff 20 ng/ml). Lower cutoff values as recommended by ROC analyses were chosen for most tests to decrease the rate of false-negatives. Analyses enabled the definition of cutoff values with good values for sensitivity. Small rates of false-positives can be accepted in forensic cases. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Assessment of rates of recanting and hair testing as a biological measure of drug use in a general population sample of young people.

    PubMed

    Taylor, Michelle; Sullivan, John; Ring, Susan M; Macleod, John; Hickman, Matthew

    2017-03-01

    We investigate the extent of and factors associated with denial of previously reported cannabis and other illicit drug use, and assess the potential of hair testing for measuring substance use in general population samples. Birth cohort study. United Kingdom, 1991-present. A total of 3643 participants who provided hair and self-report measures of cannabis and other illicit drug use in the Avon Longitudinal Study of Parents and Children (ALSPAC) at age 18 years. Denial of ever use of cannabis and other illicit drugs at age 18 following previously reported use. Positive hair drug tests for cannabis and other illicit drugs, and expected numbers of false positives and false negatives based on expected sensitivity and specificity. Cannabis and other illicit drug use was reported by 1223 and 393 individuals, respectively, before age 18 years. Of these 176 (14.4%) and 99 (25.2%), respectively, denied use at age 18. Denial of cannabis use decreased with the reporting of other substances and antisocial behaviour. Cannabis and other illicit drug use at age 18 was reported by 547 (22.5%) and 203 (8.4%) individuals, respectively. Of these, 111 (20.3%) and 13 (6.4%) were hair-positive for cannabis and other illicit drugs, respectively. Based on hair testing for cannabis use we expect 0 [95% confidence interval (CI) = 0-169] false positives and 394 (95% CI = 323-449) false negatives compared to observed 362 potential false positives and 436 potential false negatives based on self-report. In hair-positive individuals, reporting the use of other substances and antisocial behaviour decreased the odds of a negative self-report. Hair analysis provides an unreliable marker of substance use in general population samples. People who report more frequent substance use before age 18 are less likely to later deny previous substance use at age 18 than people who report occasional use. © 2016 The Authors. Addiction published by John Wiley & Sons Ltd on behalf of Society for the Study of Addiction.

  7. Assessment of rates of recanting and hair testing as a biological measure of drug use in a general population sample of young people

    PubMed Central

    Sullivan, John; Ring, Susan M.; Macleod, John; Hickman, Matthew

    2016-01-01

    Abstract Aims We investigate the extent of and factors associated with denial of previously reported cannabis and other illicit drug use, and assess the potential of hair testing for measuring substance use in general population samples. Design Birth cohort study. Setting United Kingdom, 1991–present. Participants A total of 3643 participants who provided hair and self‐report measures of cannabis and other illicit drug use in the Avon Longitudinal Study of Parents and Children (ALSPAC) at age 18 years. Measurements Denial of ever use of cannabis and other illicit drugs at age 18 following previously reported use. Positive hair drug tests for cannabis and other illicit drugs, and expected numbers of false positives and false negatives based on expected sensitivity and specificity. Findings Cannabis and other illicit drug use was reported by 1223 and 393 individuals, respectively, before age 18 years. Of these 176 (14.4%) and 99 (25.2%), respectively, denied use at age 18. Denial of cannabis use decreased with the reporting of other substances and antisocial behaviour. Cannabis and other illicit drug use at age 18 was reported by 547 (22.5%) and 203 (8.4%) individuals, respectively. Of these, 111 (20.3%) and 13 (6.4%) were hair‐positive for cannabis and other illicit drugs, respectively. Based on hair testing for cannabis use we expect 0 [95% confidence interval (CI) = 0–169] false positives and 394 (95% CI = 323–449) false negatives compared to observed 362 potential false positives and 436 potential false negatives based on self‐report. In hair‐positive individuals, reporting the use of other substances and antisocial behaviour decreased the odds of a negative self‐report. Conclusions Hair analysis provides an unreliable marker of substance use in general population samples. People who report more frequent substance use before age 18 are less likely to later deny previous substance use at age 18 than people who report occasional use. PMID:27743424

  8. Mutagenic Potential of 4-Nitrophenyl Monochloromethyl (Phenyl) Phosphinate Using the Drosophila melanogaster Sex-Linked Recessive Lethal Test.

    DTIC Science & Technology

    1983-08-01

    chromosomes were tested from the concurrent negative control. This sample size was adequate for analysis using the Fisher’s Exact test ( personal communication...study may be regarded as adequate ( personal communication - Dr. Gildengorin, Statistician, Information Sciences, Letterman Army Institute of Research...Health Sciences 0917 Arlington Road Bethesda MD 20014 CM nd Commander US Army Euvaoomens Hygine Agency US Army Research Institute Abardan Proving Ground MD

  9. The impact of anticipated HIV stigma on delays in HIV testing behaviors: findings from a community-based sample of men who have sex with men and transgender women in New York City.

    PubMed

    Golub, Sarit A; Gamarel, Kristi E

    2013-11-01

    Treatment as prevention (TaSP) is a critical component of biomedical interventions to prevent HIV transmission. However, its success is predicated on testing and identifying undiagnosed individuals to ensure linkage and retention in HIV care. Research has examined the impact of HIV-associated stigma on HIV-positive individuals, but little work has explored how anticipated HIV stigma-the expectation of rejection or discrimination against by others in the event of seroconversion-may serve as a barrier to HIV testing behaviors. This study examined the association between anticipated stigma and HIV testing behaviors among a sample of 305 men who have sex with men (MSM) and transgender women living in New York City. Participants' mean age was 33.0; 65.5% were racial/ethnic minority; and 50.2% earned <$20,000 per year. Overall, 32% of participants had not had an HIV test in the past 6 months. Anticipated stigma was negatively associated with risk perception. In multivariate models, anticipated stigma, risk perception, and younger age were significant predictors of HIV testing behaviors. Anti-HIV stigma campaigns targeting HIV-negative individuals may have the potential to significantly impact social norms around HIV testing and other biomedical strategies, such pre-exposure prophylaxis, at a critical moment for the redefinition of HIV prevention.

  10. Performance of ARCHITECT HCV core antigen test with specimens from US plasma donors and injecting drug users.

    PubMed

    Mixson-Hayden, Tonya; Dawson, George J; Teshale, Eyasu; Le, Thao; Cheng, Kevin; Drobeniuc, Jan; Ward, John; Kamili, Saleem

    2015-05-01

    Hepatitis C virus (HCV) core antigen is a serological marker of current HCV infection. The aim of this study was mainly to evaluate the performance characteristics of the ARCHITECT HCV core antigen assay with specimens from US plasma donors and injecting drug users. A total of 551 serum and plasma samples with known anti-HCV and HCV RNA status were tested for HCV core antigen using the Abbott ARCHITECT HCV core antigen test. HCV core antigen was detectable in 100% of US plasma donor samples collected during the pre-seroconversion phase of infection (anti-HCV negative/HCV RNA positive). Overall sensitivity of the HCV core antigen assay was 88.9-94.3% in samples collected after seroconversion. The correlation between HCV core antigen and HCV RNA titers was 0.959. HCV core antigen testing may be reliably used to identify current HCV infection. Published by Elsevier B.V.

  11. The role of perceived discrimination on active aging.

    PubMed

    Fernandez-Ballesteros, Rocio; Olmos, Ricardo; Santacreu, Marta; Bustillos, Antonio; Molina, Maria Angeles

    2017-07-01

    Among older adults, perceived age discrimination is highly associated with unhealthy outcomes and dissatisfaction. Active aging is a multidimensional concept described by a set of characteristics, particularly health, positive mood and control; most importantly, active aging is currently at the core of public policies. The aim of the present study was to test to what extent perceived discrimination influences active aging. Methods A total of 2005 older adults in three representative samples from regions of Germany, Mexico and Spain participated; they were tested on active aging and perceived discrimination. First, active aging was defined as high reported health, life satisfaction and self-perception of aging. Second, authors introduced the assumption that, in the total sample, structural equation modelling would confirm the hypothesis of a direct negative link between perceived age discrimination and active aging. Finally, multiple group comparison performed through structural equation modelling also provided support for the negative association between perceived discrimination and active aging proposed. In spite of the differences found among the three countries in both active aging variables and age discrimination perception, multiple group comparison indicates that regardless of the culture, perceived discrimination is a negative predictor of active aging. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. A strategical re-thinking on National Blood Donor Pool: Anti-HBc positivity related re-entry mechanisms.

    PubMed

    Yilmaz, Soner; Unlu, Aytekin; Cetinkaya, Riza Aytac; Yapar, Mehmet; Avci, Ismail Yasar; Yilmaz, Sebahattin; Eyigun, Can Polat

    2016-04-01

    Screening of blood donations for antibodies against hepatitis B core antigen (anti-HBc) is used to prevent transfusion transmitted hepatitis B virus (HBV) infection. In this study, we studied the magnitude of blood donor gain by using a re-entry mechanism in our Blood Bank of Gulhane Military Academy of Medicine. Between January and May 2013, 5148 voluntary blood donors were screened by ELISA method for HBsAg, anti-HBc total and other screening markers, prospectively. Samples with repeated reactivity for the presence of anti-HBc were further tested with four supplemental assays. We detected 515 (10%) anti-HBc positive and 4612 (90%) anti-HBc negative cases in 5127 HBsAg negative serum samples. A total of 461 (89.5%) blood units were reactive for at least one additional serologic parameter and 54 were (10.5%) negative. Isolated anti-HBc positivity rate was 1.3% (69/5127). In the isolated anti-HBc positive samples, 54 were also anti-HBe and HBeAg negative. HBV DNA was not detected in any of the samples. Applying the EDQM criteria would decrease our blood donor loss from 10% to 5.4%. As alternative re-entry mechanisms have already been presented in the literature, institution of a new policy is needed to enhance the limited blood donor pool in our system. Copyright © 2016. Published by Elsevier Ltd.

  13. Developing the Pieta House Suicide Intervention Model: a quasi-experimental, repeated measures design.

    PubMed

    Surgenor, Paul Wg; Freeman, Joan; O'Connor, Cindy

    2015-01-01

    While most crisis intervention models adhere to a generalised theoretical framework, the lack of clarity around how these should be enacted has resulted in a proliferation of models, most of which have little to no empirical support. The primary aim of this research was to propose a suicide intervention model that would resolve the client's suicidal crisis by decreasing their suicidal ideation and improve their outlook through enhancing a range of protective factors. The secondary aim was to assess the impact of this model on negative and positive outlook. A quasi-experimental, pre-test post-test repeated measures design was employed. A questionnaire assessing self-esteem, depression, and positive and negative suicidal ideation was administered to the same participants pre- and post- therapy facilitating paired responses. Multiple analysis of variance and paired-samples t-tests were conducted to establish whether therapy using the PH-SIM had a significant effect on the clients' negative and positive outlook. Analyses revealed a statistically significant effect of therapy for depression, negative suicidal ideation, self-esteem, and positive suicidal ideation. Negative outlook was significantly lower after therapy and positive outlook significantly higher. The decreased negative outlook and increased positive outlook following therapy provide some support for the proposed model in fulfilling its role, though additional research is required to establish the precise role of the intervention model in achieving this.

  14. Complete urinary tract infection (UTI) diagnosis and antibiogram using surface enhanced Raman spectroscopy (SERS)

    NASA Astrophysics Data System (ADS)

    Hadjigeorgiou, Katerina; Kastanos, Evdokia; Kyriakides, Alexandros; Pitris, Costas

    2012-03-01

    There are three stages to a complete UTI diagnosis: (1) identification of a urine sample as positive/negative for an infection, (2) identification of the responsible bacterium, (3) antibiogram to determine the antibiotic to which the bacteria are most sensitive to. Using conventional methods, all three stages require bacterial cultures in order to provide results. This long delay in diagnosis causes a rise in ineffective treatments, chronic infections, health care costs and antibiotic resistance. In this work, SERS is used to identify a sample as positive/negative for a UTI as well as to obtain an antibiogram against different antibiotics. SERS spectra of serial dilutions of E. coli bacteria mixed with silver nanoparticles, showed a linear correlation between spectral intensity and concentration. For antibiotic sensitivity testing, SERS spectra of three species of gram negative bacteria were collected four hours after exposure to the antibiotics ciprofloxacin and amoxicillin. Spectral analysis revealed clear separation between bacterial samples exposed to antibiotics to which they were sensitive and samples exposed to antibiotics to which they were resistant. With the enhancement provided by SERS, the technique can be applied directly to urine samples leading to the development of a new, rapid method for UTI diagnosis and antibiogram.

  15. A HUPO test sample study reveals common problems in mass spectrometry-based proteomics

    PubMed Central

    Bell, Alexander W.; Deutsch, Eric W.; Au, Catherine E.; Kearney, Robert E.; Beavis, Ron; Sechi, Salvatore; Nilsson, Tommy; Bergeron, John J.M.

    2009-01-01

    We carried out a test sample study to try to identify errors leading to irreproducibility, including incompleteness of peptide sampling, in LC-MS-based proteomics. We distributed a test sample consisting of an equimolar mix of 20 highly purified recombinant human proteins, to 27 laboratories for identification. Each protein contained one or more unique tryptic peptides of 1250 Da to also test for ion selection and sampling in the mass spectrometer. Of the 27 labs, initially only 7 labs reported all 20 proteins correctly, and only 1 lab reported all the tryptic peptides of 1250 Da. Nevertheless, a subsequent centralized analysis of the raw data revealed that all 20 proteins and most of the 1250 Da peptides had in fact been detected by all 27 labs. The centralized analysis allowed us to determine sources of problems encountered in the study, which include missed identifications (false negatives), environmental contamination, database matching, and curation of protein identifications. Improved search engines and databases are likely to increase the fidelity of mass spectrometry-based proteomics. PMID:19448641

  16. Relationship of spermatoscopy, prostatic acid phosphatase activity and prostate-specific antigen (p30) assays with further DNA typing in forensic samples from rape cases.

    PubMed

    Romero-Montoya, Lydia; Martínez-Rodríguez, Hugo; Pérez, Miguel Antonio; Argüello-García, Raúl

    2011-03-20

    In the forensic laboratory the biological analyses for rape investigation commonly include vaginal swabs as sample material combined to biochemical tests including sperm cytology (SC) and detection of acid phosphatase activity (AP) and prostate-specific antigen (PSA, p30) for the conclusive identification of semen components. Most reports comparing these tests relied on analysis of semen samples or donor swabs taken under controlled conditions; however their individual or combined efficacy under real live sampling conditions in different laboratories is largely unknown. We carried out SC, APA and PSA analyses in vaginal swabs collected from casework rapes submitted to Mexican Forensic Laboratories at Texcoco and Toluca. On the basis of positive and negative results from each assay and sample, data were classified into eight categories (I-VIII) and compared with those obtained in the two only similar studies reported in Toronto, Canada and Hong Kong, China. SC and APA assays had the higher overall positivity in Toluca and Texcoco samples respectively and otherwise PSA had a lower but very similar positivity between these two laboratories. When compared to the previous studies some similarities were found, namely similar frequencies (at a ratio of approximately 1 out of 3) of samples being positive or negative by all techniques (Categories I and VI respectively) and a comparable overall positivity of APA and SC but higher than that of PSA. Indeed the combined results of using SC, APA and PSA tests was considered as conclusive for semen detection from approximately 1 out of 3 cases (Category I) to approximately 1 out of 2 cases in a scenario where at least SC is positive, strongly presumptive in 2 out of 3 cases (with at least one test positive) and the remainder 1 out of 3 cases (Category VI) suggested absence of semen. By determining Y-STR polymorphisms (12-loci) in additional samples obtained at Toluca laboratory, complete DNA profiles were determined from all Category I samples, none marker was detected from all Category VI samples and mostly partial profiles were obtained from samples of other categories. These observations give an overview on the variability in efficacy of each test performed at different laboratories and provide a general notion about the in praxis contribution of SC, APA and PSA tests for further DNA typing in the forensic analysis of rape. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  17. Prospective Investigation of the Contrast Avoidance Model of Generalized Anxiety and Worry.

    PubMed

    Crouch, Tara A; Lewis, Jamie A; Erickson, Thane M; Newman, Michelle G

    2017-07-01

    The factors that maintain generalized anxiety disorder (GAD) symptoms and worry over time are not entirely clear. The Contrast Avoidance Model (CAM) postulates that individuals at risk for pathological worry and GAD symptoms uniquely fear emotional shifts from neutral or positive emotions into negative emotional states, and consequently use worry to maintain negative emotion in order to avoid shifts or blunt the effect of negative contrasts. This model has received support in laboratory experiments, but has not been investigated prospectively in the naturalistic context of daily life. The present study tested the CAM in a longitudinal experience sampling study with a subclinical sample. Participants selected to represent a broad range of symptoms (N = 92) completed baseline measures of GAD and depression symptoms, and eight weekly assessments of worry, experiences of negative emotional contrasts during their worst event of the week, and situation-specific negative emotion. Consistent with the CAM, GAD symptoms prospectively predicted higher endorsement of negative contrast experiences as worst events, independent of depression symptoms. Unsurprisingly, higher negative contrasts predicted higher negative emotion. However, both higher baseline GAD symptoms and weekly worry uniquely moderated (reduced) this relationship, providing consistent support for the idea that worry may blunt the emotional effects of contrasts. Depression symptoms did not have the same moderating effect. These findings support the CAM in an ecologically valid context. Copyright © 2016. Published by Elsevier Ltd.

  18. Cs-doped Mo as surface converter for H{sup −}/D{sup −} generation in negative ion sources: First steps and proof of principle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schiesko, L., E-mail: loic.schiesko@ipp.mpg.de; Hopf, C.; Höschen, T.

    2015-04-08

    In a proof-of-principle study, molybdenum samples were implanted with a very small dose of Cs in order to test the properties of the compound as a surface converter for negative hydrogen ion production. First results on the properties of Cs doped Mo compounds show a reduction of the work function and a stable H{sup −} yield up to four hours in low density hydrogen plasma. The implanted Cs atoms were stable in the Mo lattice over one year for samples stored in vacuum and not exposed to the plasma. The surface H{sup −} generation mechanisms were identified and a comparisonmore » of the negative ion yield with pure Mo showed that the Cs doped Mo sample’s yield was much larger.« less

  19. Enzyme-linked immunosorbent assay for detection of pertussis immunoglobulin A in nasopharyngeal secretions as an indicator of recent infection.

    PubMed Central

    Goodman, Y E; Wort, A J; Jackson, F L

    1981-01-01

    An enzyme-linked immunosorbent assay was developed for detection of immunoglobulin A (IgA) antibody to Bordetella pertussis (PsIgA) in nasopharyngeal secretions as an indicator of recent infection. Secretion specimens submitted for pertussis culture were examined for PsIgA by this technique. Of 348 specimens tested, B. pertussis was cultured from 57, and PsIgA was detected in 8 culture-positive and 40 culture-negative specimens. The average time between onset of symptoms and specimen collection for the culture-positive, PsIgA-negative specimens was 10 days; for the culture-positive, PsIgA-positive specimens, 15 days; and for the culture-negative, PsIgA-positive specimens, 36 days. Examination of paired samples available from several culture-proven cases demonstrated conversion from a negative PsIgA in the early sample to a positive PsIgA in the follow-up sample. Our results indicate that PsIgA is produced during natural human infection and does not arise as a result of parenteral vaccination. PsIgA usually appears in the nasopharyngeal secretions during the second or third week of illness and persists for at least 3 months. The detection of PsIgA in secretions may be a valuable diagnostic aid in culture-negative patients with pertussis. Images PMID:6259201

  20. Alkaline peptone water enrichment with a dipstick test to quickly detect and monitor cholera outbreaks.

    PubMed

    Bwire, Godfrey; Orach, Christopher Garimoi; Abdallah, Dauda; Debes, Amanda Kay; Kagirita, Atek; Ram, Malathi; Sack, David A

    2017-11-21

    Detection, confirmation and monitoring of cholera outbreaks in many developing countries including Uganda is a big challenge due to lack of the required resources and the time the test takes. Culture method which takes 24-48 h to get the feedback and requires highly skilled laboratory staff plus other complex resources is the standard test. This study evaluated the new cholera rapid detection method that relies on Crystal VC dipsticks after enrichment with alkaline peptone water (APW) against the culture method for monitoring the progress of cholera outbreaks in rural setting. We conducted the study between March and June 2015. Fresh stool samples and rectal swabs were incubated in 1% APW for 6 h at room temperature before testing with RDT following the manufacturer's instruction. The same stool sample was cultured to isolate V. cholerae in the standard manner. We also reviewed patient registers to epidemiologically describe the cholera epidemic. We tested stool from 102 consenting suspected cholera patients reporting during daytime at Bwera Hospital (n = 69), Kilembe Mines Hospital (n = 4) and Kinyabwama Health Centre (n = 29). Ninety one (91) samples were positive and nine samples were negative according to both methods. One (1) sample was positive only by dipstick and one sample was positive only by culture (sensitivity of 99%, specificity of 90%, Positive Predictive Value of 99% and Negative Predictive Value of 90%). Overall, 146 suspected cholera cases and two deaths, (case fatality rate of 1.36%) were recorded during the study period. Among the cases aged 1-9 years, 63% (50/79) were males while in those aged 20-49 years, 76% (34/45) were females. Our findings showed that the modified dipstick test after enrichment with 1% APW had high level of accuracy in detection of V. cholerae and is quick, affordable alternative cholera outbreak monitoring tool in resource constrained settings. However, culture method should remain for cholera epidemic confirmation, for monitoring of antibiotic sensitivity and for production of pure isolates for molecular characterization. Further studies should be done to better understand the observed age and sex case distribution, in Kasese district.

  1. Quantification of hepatitis C virus RNA in serum by branched DNA-based signal amplification assays.

    PubMed

    Pawlotsky, J M; Martinot-Peignoux, M; Poveda, J D; Bastie, A; Le Breton, V; Darthuy, F; Rémiré, J; Erlinger, S; Dhumeaux, D; Marcellin, P

    1999-05-01

    The objective of the study was to compare the clinical sensitivity and specificity of versions 1.0 and 2.0 of the branched DNA (bDNA)-based hepatitis C virus (HCV) RNA quantification assay, and also to compare the values yielded by the two versions according to the HCV genotype. Serum samples from 268 patients tested routinely by a non-quantitative HCV RNA PCR assay (group A) were tested with version 2.0 of the bDNA assay. Samples from 342 HCV PCR-positive patients with chronic hepatitis C eligible for interferon treatment (group B) were tested with both version 1.0 and version 2.0 of the bDNA assay. Version 2.0 had a clinical sensitivity of 92% (95% confidence interval (CI): 87-97%) in group A and 89% (86-92%) in group B. In group B, the gain in sensitivity with bDNA 2.0 was 16% relative to bDNA 1.0 (P < 0.001). The log values of the two assays correlated with samples positive by both assays (r = 0.83, P < 0.0001), but the distribution of values was larger in samples containing HCV genotypes 2 and 3. The mean ratio of assay 2.0/assay 1.0 values was 1.69 +/- 1.44 (range: 0.33-13.43). The mean ratio was close to 1 with samples containing genotype 1 or 4, but ranged from 0.33 to more than 5. The mean ratio was close to 3 with samples containing genotype 2 or 3, and ranged from 0.5 to more than 13. HCV RNA levels were significantly lower in samples containing genotype 4 than in those containing other genotypes. Sera from 200 anti-HCV-negative, HCV RNA PCR-negative blood donors (group C), and from 164 anti-HCV-negative patients with symptoms of chronic liver disease (group D) were used to assess the clinical specificity of bDNA 2.0. In addition, samples with an HCV RNA titer between 0.2 (assay cutoff) and 0.5 MEq/ml from a group of 546 patients tested routinely for HCV RNA load by bDNA 2.0 (group E) were retested by bDNA 2.0 and by qualitative PCR. The specificity of bDNA 2.0 was 100% (98-100%) in group C and 99% (97-100%) in group D. Among the 41 samples from group E, 38 were positive by bDNA 2.0 retesting (36 were PCR-positive) and three were negative by bDNA 2.0 retesting (all were PCR-positive). It is concluded that version 2.0 of the bDNA assay is markedly more sensitive than version 1.0 and has a good specificity. In contrast with version 1.0, version 2.0 is not influenced by the HCV genotype. The relationship between values obtained with assays 1.0 and 2.0 on clinical specimens is not linear, indicating that HCV RNA titers cannot reliably be calculated from the results of version 1.0.

  2. Contrastive Analysis and Research on Negative Pressure Beam Tube System and Positive Pressure Beam Tube System for Mine Use

    NASA Astrophysics Data System (ADS)

    Wang, Xinyi; Shen, Jialong; Liu, Xinbo

    2018-01-01

    Against the technical defects of universally applicable beam tube monitoring system at present, such as air suction in the beam tube, line clogging, long sampling time, etc., the paper analyzes the current situation of the spontaneous combustion fire disaster forecast of mine in our country and these defects one by one. On this basis, the paper proposes a research thought that improving the positive pressure beam tube so as to substitute the negative pressure beam tube. Then, the paper introduces the beam tube monitoring system based on positive pressure technology through theoretical analysis and experiment. In the comparison with negative pressure beam tube, the paper concludes the advantage of the new system and draws the conclusion that the positive pressure beam tube is superior to the negative pressure beam tube system both in test result and test time. At last, the paper proposes prospect of the beam tube monitoring system based on positive pressure technology.

  3. Partial hydatidiform mole with false-negative urine human chorionic gonadatropin test in the emergency department.

    PubMed

    Mundangepfupfu, Tichaendepi; Waseem, Muhammad

    2014-03-01

    Hydatidiform mole (molar pregnancy) is a benign tumor of placental trophoblastic cells, which release human chorionic gonadotropin (hCG). Several case reports have described complete hydatidiform moles with false-negative urine qualitative hCG tests. These negative pregnancy tests have been attributed to the hook effect. We report an unusual presentation of a partial mole and review an alternative explanation for the negative hCG test. As partial moles are usually not associated with a large proliferation of trophoblastic cells, levels of hCG are commonly < 100,000 mIU/mL. The most common presentation of a hydatidiform mole is vaginal bleeding. Hydatidiform mole is associated with a risk of malignant transformation and disseminated disease. In a pregnant patient, vaginal bleeding and abdominal pain are common presentations. Molar pregnancy is an uncommon cause of abdominal pain and vaginal bleeding that should be considered. A 47-year-old female presented to the emergency department with abdominal pain and vaginal bleeding. Urine qualitative hCG was negative and serum quantitative hCG was 1,094,950 mIU/mL. Pelvic ultrasonography showed a uterine cavity containing a soft-tissue mass with multiple cystic lesions and the hydatidiform mole was extracted with suction curettage. Tissue pathology confirmed partial hydatidiform mole. In addition to the hook effect, we present another possible explanation for the false-negative test; namely the inability of some assays to detect hCG-degradation products, which may be higher in clinical samples from patients with hydatidiform mole. This case underscores the importance of knowing the limitations of the commonly used hCG assays. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Examining the link between weight suppression and non-suicidal self-injurious behaviors.

    PubMed

    Keel, Pamela K; Jean Forney, K; Buchman-Schmitt, Jennifer M; Kennedy, Grace A; Joiner, Thomas E

    2018-06-02

    Given the negative consequences of excess weight, a large portion of the US population is seeking to obtain and maintain weight loss. Weight Suppression (WS) represents the difference between previous highest adult weight and current weight and may have negative psychological consequences. The current study examined the link between WS and lifetime non-suicidal self-injurious (NSSI) behavior and explored indirect effects in this link using survey data in two large samples. Sample 1 included 1011 college students (67% female, mean age = 19 years); Sample 2 included 2461 participants from an epidemiological study (68% female, mean age = 34 years). Models of direct and indirect effects were tested in MPlus using bootstrapping. As hypothesized, greater WS was associated with increased likelihood of lifetime NSSI in both samples (OR = 1.05 and 1.02). In both samples, significant indirect effects of drive for thinness (Total R 2  = 0.06 and 0.09) and depressive symptoms (Total R 2  = 0.13 and 0.29) accounted for this association. Alternative models in which the indirect effect of WS was tested in associations between drive for thinness or depressive symptoms and NSSI were not supported. Results suggest that the link between WS and lifetime NSSI may be accounted for by eating or mood-related pathology. Future research should test whether addressing associated eating and mood problems would eliminate the link between WS and NSSI as a means for reducing suicide risk. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Ascorbic acid interference in the measurement of serum biochemical parameters: in vivo and in vitro studies.

    PubMed

    Martinello, Flávia; da Silva, Edson Luiz

    2006-04-01

    To investigate the negative interference of ascorbic acid in serum biochemical tests in relation to the dose of vitamin C intake and to the time of blood collection. Healthy volunteers (n = 18) consumed daily doses of vitamin C (0.25-4.0 g) for 1 week and serum parameters were assayed prior to the experiment and on the eighth day of consumption. Blood samples were collected 4, 12 and 24 h after vitamin C intake. Serum levels of ascorbic acid increased significantly after vitamin C ingestion inhibiting urate and total bilirubin tests 4 and 12 h after intake (P < 0.01). A significant negative interference occurred up to 24 h after consumption of 4 g vitamin C for the urate test. In contrast, ingestion of vitamin C did not show interference in glucose, triglyceride and cholesterol tests. Addition of ascorbic acid to serum inhibited the urate test to a similar extent to that observed after vitamin C intake. However, after ingesting vitamin C, the interference for the bilirubin test was greater than that of the in vitro interference. Commonly taken doses of supplementary vitamin C interfered negatively with the serum urate test based on the Trinder method, and with bilirubin metabolism.

  6. Oxybuprocaine induces a false-positive response in immunochromatographic SAS Adeno Test.

    PubMed

    Hoshino, Takeshi; Takanashi, Taiji; Okada, Morio; Uchida, Sunao

    2002-04-01

    To investigate whether a solution of oxybuprocaine hydrochloride, 0.4%, results in a false-positive response in an immunochromatographic SAS Adeno Test. Experimental study. Physiologic saline and 2% lidocaine. Each chemical (100 microl) was diluted in a transport medium. Five drops (200 microl) of the resultant solution were dispensed into the round sample well of a test device. Fifteen samples were tested in each group. Ten minutes after the start of the test, a colored line in the "specimen" portion of the test membrane was visually read as positive or negative by a masked technician. No positive reaction was observed in the control groups (physiologic saline and lidocaine). A false-positive reaction was observed in six samples (33.3%) in the oxybuprocaine group. The positive rate was significantly higher in the oxybuprocaine group compared with those in control groups (P = 0.0062, Fisher's extract probability test). Oxybuprocaine may induce a false-positive reaction in an immunochromatographic SAS Adeno Test. We recommend the use of lidocaine, instead of oxybuprocaine, for local anesthesia in taking eye swabs from patients with suspected adenovirus infection.

  7. The modified Hodge test is a useful tool for ruling out Klebsiella pneumoniae carbapenemase.

    PubMed

    Cury, Ana Paula; Andreazzi, Denise; Maffucci, Márcia; Caiaffa-Junior, Hélio Hehl; Rossi, Flávia

    2012-12-01

    Enterobacteriaceae bacteria harboring Klebsiella pneumoniae carbapenemase are a serious worldwide threat. The molecular identification of these pathogens is not routine in Brazilian hospitals, and a rapid phenotypic screening test is desirable. This study aims to evaluate the modified Hodge test as a phenotypic screening test for Klebsiella pneumoniae carbapenemase. From April 2009 to July 2011, all Enterobacteriaceae bacteria that were not susceptible to ertapenem according to Vitek2 analysis were analyzed with the modified Hodge test. All positive isolates and a random subset of negative isolates were also assayed for the presence of blaKPC. Isolates that were positive in modified Hodge tests were sub-classified as true-positives (E. coli touched the ertapenem disk) or inconclusive (distortion of the inhibition zone of E. coli, but growth did not reach the ertapenem disk). Negative results were defined as samples with no distortion of the inhibition zone around the ertapenem disk. Among the 1521 isolates of Enterobacteriaceae bacteria that were not susceptible to ertapenem, 30% were positive for blaKPC, and 35% were positive according to the modified Hodge test (81% specificity). Under the proposed sub-classification, true positives showed a 98% agreement with the blaKPC results. The negative predictive value of the modified Hodge test for detection was 100%. KPC producers showed high antimicrobial resistance rates, but 90% and 77% of these isolates were susceptible to aminoglycoside and tigecycline, respectively. Standardizing the modified Hodge test interpretation may improve the specificity of KPC detection. In this study, negative test results ruled out 100% of the isolates harboring Klebsiella pneumoniae carbapenemase 2. The test may therefore be regarded as a good epidemiological tool.

  8. The impact of environmental conditions on Campylobacter jejuni survival in broiler faeces and litter.

    PubMed

    Smith, Shaun; Meade, Joseph; Gibbons, James; McGill, Kevina; Bolton, Declan; Whyte, Paul

    2016-01-01

    Campylobacter jejuni is the leading bacterial food-borne pathogen within the European Union, and poultry meat is an important vehicle for its transmission to humans. However, there is limited knowledge about how this organism persists in broiler litter and faeces. The aim of this study was to assess the impact of a number of environmental parameters, such as temperature, humidity, and oxygen, on Campylobacter survival in both broiler litter and faeces. Used litter was collected from a Campylobacter-negative broiler house after final depopulation and fresh faeces were collected from transport crates. Samples were confirmed as Campylobacter negative according to modified ISO methods for veterinary samples. Both sample matrices were inoculated with 9 log10 CFU/ml C. jejuni and incubated under high (≥85%) and low (≤70%) relative humidity conditions at three different temperatures (20°C, 25°C, and 30°C) under both aerobic and microaerophilic atmospheres. Inoculated litter samples were then tested for Campylobacter concentrations at time zero and every 2 hours for 12 hours, while faecal samples were examined at time zero and every 24 hours for 120 hours. A two-tailed t-test assuming unequal variance was used to compare mean Campylobacter concentrations in samples under the various temperature, humidity, and atmospheric conditions. C. jejuni survived significantly longer (P≤0.01) in faeces, with a minimum survival time of 48 hours, compared with 4 hours in used broiler litter. C. jejuni survival was significantly enhanced at 20°C in all environmental conditions in both sample matrices tested compared with survival at 25°C and 30°C. In general, survival was greater in microaerophilic compared with aerobic conditions in both sample matrices. Humidity, at the levels examined, did not appear to significantly impact C. jejuni survival in any sample matrix. The persistence of Campylobacter in broiler litter and faeces under various environmental conditions has implications for farm litter management, hygiene, and disinfection practices.

  9. Cytological Sampling Versus Forceps Biopsy During Percutaneous Transhepatic Biliary Drainage and Analysis of Factors Predicting Success

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tapping, C. R.; Byass, O. R.; Cast, J. E. I., E-mail: james.cast@hey.nhs.uk

    Purpose: To assess the accuracy of cytological sampling and forceps biopsy in obstructing biliary lesions and to identify factors predictive of success. Methods: Consecutive patients (n = 119) with suspected malignant inoperable obstructive jaundice treated with percutaneous transhepatic biliary drainage during 7 years were included (60 male; mean age 72.5 years). All patients underwent forceps biopsy plus cytological sampling by washing the forceps device in cytological solution. Patient history, procedural and pathological records, and clinical follow-up were reviewed. Statistical analysis included chi-square test and multivariate regression analysis. Results: Histological diagnosis after forceps biopsy was more successful than cytology: Sensitivity wasmore » 78 versus 61%, and negative predictive value was 30 versus 19%. Cytology results were never positive when the forceps biopsy was negative. The cytological sample was negative and forceps sample positive in 2 cases of cholangiocarcinoma, 16 cases of pancreatic carcinoma, and 1 case of benign disease. Diagnostic accuracy was predicted by low bilirubin (p < 0.001), aspartate transaminase (p < 0.05), and white cell count (p {<=} 0.05). Conclusions: This technique is safe and effective and is recommended for histological diagnosis during PTBD in patients with inoperable malignant biliary strictures. Diagnostic yield is greater when bilirubin levels are low and there is no sepsis; histological diagnosis by way of forceps biopsy renders cytological sampling unnecessary.« less

  10. Design of a multiplex PCR for Streptococcus pneumoniae, Haemophilus influenzae, Mycoplasma pneumoniae and Chlamydophila pneumoniae to be used on sputum samples.

    PubMed

    Strålin, Kristoffer; Bäckman, Anders; Holmberg, Hans; Fredlund, Hans; Olcén, Per

    2005-02-01

    A multiplex PCR (mPCR) was developed for simultaneous detection of specific genes for Streptococcus pneumoniae (lytA), Mycoplasma pneumoniae (P1), Chlamydophila pneumoniae (ompA), and Haemophilus influenzae (16S rRNA, with verification PCR for P6). When the protocol was tested on 257 bacterial strains belonging to 37 different species, no false negatives and only one false positive were noted. One Streptococcus mitis out of thirty was positive for lytA. In a pilot application study of 81 sputum samples from different patients with suspected lower respiratory tract infection (LRTI), mPCR identified S. pneumoniae in 25 samples, H. influenzae in 29, M. pneumoniae in 3, and C. pneumoniae in 1. All samples culture positive for S. pneumoniae (n=15) and H. influenzae (n=15) were mPCR positive for the same bacteria. In a pilot control study with nasopharyngeal swabs and aspirates from 10 healthy adults, both culture and mPCR were negative. No PCR inhibition was found in any of the mPCR-negative sputum or nasopharyngeal samples. Whether all samples identified as positive by mPCR are truly positive in an aetiological perspective regarding LRTI remains to be evaluated in a well-defined patient material. In conclusion, the mPCR appears to be a promising tool in the aetiological diagnostics of LRTI.

  11. Detection of human parvovirus B19 in serum samples from children under 5 years of age with rash-fever illnesses in the Democratic Republic of the Congo.

    PubMed

    Wawina, Tony Bokalanga; Tshiani, Olivier Mbaya; Ahuka, Steve Mundeke; Pukuta, Elisabeth Simbu; Aloni, Michel Ntetani; Kasanga, Christopher Jacob; Muyembe, Jean-Jacques Tamfum

    2017-12-01

    It has been demonstrated that infection with human parvovirus B19 (B19V) is associated with rash-fever illnesses. The present study aimed to investigate B19V as an aetiological agent of rash-fever syndromes in Congolese children confirmed as measles and rubella IgM-negative. An ELISA IgM test and PCR were performed to screen for B19V. A total of 177 archived serum samples were randomly selected from the measles biobank of the National Institute for Biomedical Research (INRB). Samples were investigated for anti-B19V IgM and B19V DNA. These samples originated from children <5years of age with measles-like rashes, previously confirmed as negative for both measles and rubella IgM. Out of 177 serum samples tested by ELISA and 168 tested by PCR, 109 were positive for B19V IgM antibodies (61.6%) and 87 (51.8%) were positive for B19V DNA. Positive samples in both assays were from all provinces of DRC. B19V plays a role in rash-fever illnesses in children under 5 years of age suspected of having measles or rubella infections in DRC. As an aetiological cause of rash and fever syndromes, the present study demonstrates that B19V should also be considered during the laboratory investigation of rash-fever illnesses in DRC, particularly in the paediatric population. There is a need to conduct further studies in order to gain a better understanding of the spatiotemporal pattern of B19V and to define the genotype(s) of B19V circulating in DRC. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  12. Highly Sensitive Assay for Detection of Enterovirus in Clinical Specimens by Reverse Transcription-PCR with an Armored RNA Internal Control

    PubMed Central

    Beld, Marcel; Minnaar, René; Weel, Jan; Sol, Cees; Damen, Marjolein; van der Avoort, Harry; Wertheim-van Dillen, Pauline; Breda, Alex van; Boom, René

    2004-01-01

    The objective of the present study was the development of a diagnostic reverse transcription (RT)-PCR for the specific detection of enterovirus (EV) RNA in clinical specimens controlled by an internal control (IC) RNA. The IC RNA contains the same primer binding sites as EV RNA but has a different probe region. The IC RNA was packaged into an MS2 phage core particle (armored) and was added to the clinical sample to allow monitoring of both extraction efficiency and RT-PCR efficiency. Serial dilutions of the IC RNA were made, and the detection limit of the RT-PCR was tested in a background of EV RNA-negative cerebrospinal fluid. The sensitivity and specificity of the RT-PCR assay were tested by using all 64 known EV serotypes, several non-EV serotypes, and two Quality Control for Molecular Diagnostics (QCMD) Program EV proficiency panels from 2001 and 2002. In total, 322 clinical specimens were tested by RT-PCR, and to establish the clinical utility of the RT-PCR, a comparison of the results of viral culture and RT-PCR was done with 87 clinical specimens. The lower limit of sensitivity was reached at about 150 copies of IC RNA/ml. All 64 EV serotypes were positive, while all non-EV serotypes were negative. All culture-positive samples of the 2001 QCMD proficiency panel (according to the 50% tissue culture infective doses per milliliter) were positive by RT-PCR. Invalid results, i.e., negativity for both EV RNA and IC RNA, due to inhibition of RT-PCR were observed for 33.3% of the members of the 2002 QCMD proficiency panel and 3.1% of the clinical specimens. Inhibition of RT-PCR could be relieved by the addition of 400 ng of bovine α-casein per μl to both the RT reaction mixture and the PCR mixture. With this optimized protocol, the results for all samples of the 2002 QCMD proficiency panel and all clinical specimens except one fecal sample (0.3%) were valid. Evaluation of the clinical samples demonstrated that EV infection could be detected in 12 of 87 samples (13.8%) by RT-PCR, while viral culture was negative. Our data show that the RT-PCR with armored IC RNA offers a very reliable and rapid diagnostic tool for the detection of EV in clinical specimens and that the addition of bovine α-casein relieved inhibition of the RT-PCR for 99.7% of clinical specimens. PMID:15243060

  13. Performance of a New HPV Cervi-Collect Collection and Transportation Kit

    PubMed Central

    Chernesky, M.; Huang, S.; Jang, D.; Erickson, B.; Salituro, J.; Engel, H.; Gilchrist, J.; Neuscheler, P.; Mak, W. B.; Abravaya, K.

    2012-01-01

    Background. Liquid-based Pap (L-Pap) media are used for Pap and human papillomavirus (HPV) testing. Objectives. To compare RealTime High Risk (HR) HPV testing of a new collection kit (Cervi-Collect) and PreservCyt L-Pap specimens. To determine ease of use and safety of Cervi-Collect. Methods. L-Pap samples (n = 203) were tested with HC2 and RealTime HR HPV and Cervi-Collect with RealTime HR HPV. Discordant samples were genotyped. Results. L-Pap and Cervi-Collect specimens tested by RealTime HR HPV showed 93.1% agreement (Kappa 0.86). RealTime HR HPV and HC2 on L-Pap had 90.3% agreement (Kappa 0.80). RealTime HR HPV on Cervi-Collect and HC2 on L-Pap showed 88.2% agreement (Kappa 0.76). Sixteen of 21 samples which were HC2 negative and RealTime HR HPV positive on L-Pap or Cervi-Collect contained HR HPV genotypes. Eleven healthcare collectors were in strong agreement on a usability and safety questionnaire. Conclusion. Cervi-Collect samples were easy to collect and showed strong agreement with L-Pap samples tested with RealTime HR HPV or HC2. PMID:22174716

  14. Bacteriology of Dehydrated Space Foods 1

    PubMed Central

    Powers, Edmund M.; Ay, Carl; El-Bisi, Hamed M.; Rowley, Durwood B.

    1971-01-01

    The initial bacteriological requirement established in 1964 for space foods by the U.S. Army Natick Laboratories are: a total aerobic plate count (≤ 10,000 per g), a total coliform count (≤ 10 per g), fecal coliforms (negative per gram), fecal streptococci (≤ 20 per g), coagulase-positive staphylococci (negative in 5 g) and salmonellae (negative in 10 g). Of the space foods and prototypes tested during 1968 and 1969, 93% complied with the total aerobic plate count, 98% had less than 1 coliform per g, and 99% were negative for fecal coliforms; 88% complied with the streptococci requirement; 100 and 98% were negative for staphylococci and salmonellae, respectively. Nineteen food samples which did not comply (as indicated parenthetically by actual counts per gram) with the requirements were (i) total aerobic plate count: beef soup and gravy base (18,000), chicken soup and gravy base (57,000), spaghetti with meat sauce (12,100 and 14,000), sugared coffee (> 300,000), chocolate ice cream cubes (20,000), and each of four samples of chocolate candy (12,000 to 61,000); (ii) coliforms: two out of three vanilla milk drinks (16 and 127) and one beef hash bar (14); (iii) fecal coliforms: one sample of chicken soup and gravy base positive; (iv) fecal streptococci: two samples of peanut cubes (40 and 108), coconut cubes (75), chicken soup and gravy base (2,650), beef soup and gravy base (33), and five out of six flavored milk drinks (23 to 300); (v) salmonellae: one each of chicken and beef soup and gravy base were positive. Images PMID:4940878

  15. Multi-site evaluation of the LN34 pan-lyssavirus real-time RT-PCR assay for post-mortem rabies diagnostics

    PubMed Central

    Dettinger, Lisa; Powell, James W.; Seiders, Melanie; Condori, Rene Edgar Condori; Griesser, Richard; Okogi, Kenneth; Carlos, Maria; Pesko, Kendra; Breckenridge, Mike; Simon, Edson Michael M.; Chu, Maria Yna Joyce V.; Davis, April D.; Brunt, Scott J.; Orciari, Lillian; Yager, Pamela; Carson, William C.; Hartloge, Claire; Saliki, Jeremiah T.; Deldari, Mojgan; Hsieh, Kristina; Wadhwa, Ashutosh; Wilkins, Kimberly; Rabideau, Patricia; Gruhn, Nina; Cadet, Rolain; Isloor, Shrikrishna; Nath, Sujith S.; Joseph, Tomy; Gao, Jinxin; Wallace, Ryan; Reynolds, Mary; Olson, Victoria A.

    2018-01-01

    Rabies is a fatal zoonotic disease that requires fast, accurate diagnosis to prevent disease in an exposed individual. The current gold standard for post-mortem diagnosis of human and animal rabies is the direct fluorescent antibody (DFA) test. While the DFA test has proven sensitive and reliable, it requires high quality antibody conjugates, a skilled technician, a fluorescence microscope and diagnostic specimen of sufficient quality. The LN34 pan-lyssavirus real-time RT-PCR assay represents a strong candidate for rabies post-mortem diagnostics due to its ability to detect RNA across the diverse Lyssavirus genus, its high sensitivity, its potential for use with deteriorated tissues, and its simple, easy to implement design. Here, we present data from a multi-site evaluation of the LN34 assay in 14 laboratories. A total of 2,978 samples (1,049 DFA positive) from Africa, the Americas, Asia, Europe, and the Middle East were tested. The LN34 assay exhibited low variability in repeatability and reproducibility studies and was capable of detecting viral RNA in fresh, frozen, archived, deteriorated and formalin-fixed brain tissue. The LN34 assay displayed high diagnostic specificity (99.68%) and sensitivity (99.90%) when compared to the DFA test, and no DFA positive samples were negative by the LN34 assay. The LN34 assay produced definitive findings for 80 samples that were inconclusive or untestable by DFA; 29 were positive. Five samples were inconclusive by the LN34 assay, and only one sample was inconclusive by both tests. Furthermore, use of the LN34 assay led to the identification of one false negative and 11 false positive DFA results. Together, these results demonstrate the reliability and robustness of the LN34 assay and support a role for the LN34 assay in improving rabies diagnostics and surveillance. PMID:29768505

  16. Herpes viral culture of lesion

    MedlinePlus

    ... grow in the laboratory dish and the skin sample used in the test did not contain any herpes virus. Be aware that a normal (negative) culture does not always mean that you do not have a herpes infection or have not had one in the past.

  17. High-Throughput Direct Fecal PCR Assay for Detection of Mycobacterium avium subsp. paratuberculosis in Sheep and Cattle

    PubMed Central

    Waldron, Anna M.; Galea, Francesca; Whittington, Ann-Michele; Saunders, Vanessa F.; Begg, Douglas J.; de Silva, Kumudika; Purdie, Auriol C.; Whittington, Richard J.

    2014-01-01

    Johne's disease (JD) is a chronic enteric disease caused by Mycobacterium avium subsp. paratuberculosis that affects ruminants. Transmission occurs by the fecal-oral route. A commonly used antemortem diagnostic test for the detection of M. avium subsp. paratuberculosis in feces is liquid culture; however, a major constraint is the 2- to 3-month incubation period needed for this method. Rapid methods for the detection of M. avium subsp. paratuberculosis based on PCR have been reported, but comprehensive validation data are lacking. We describe here a new test, the high-throughput-Johnes (HT-J), to detect M. avium subsp. paratuberculosis in feces. Its diagnostic accuracy was compared with that of liquid radiometric (Bactec) fecal culture using samples from cattle (1,330 samples from 23 herds) and sheep (596 samples from 16 flocks). The multistage protocol involves the recovery of M. avium subsp. paratuberculosis cells from a fecal suspension, cell rupture by bead beating, extraction of DNA using magnetic beads, and IS900 quantitative PCR. The limit of detection of the assay was 0.0005 pg, and the limit of quantification was 0.005 pg M. avium subsp. paratuberculosis genomic DNA. Only M. avium subsp. paratuberculosis was detected from a panel of 51 mycobacterial isolates, including 10 with IS900-like sequences. Of the 549 culture-negative fecal samples from unexposed herds and flocks, 99% were negative in the HT-J test, while 60% of the bovine- and 84% of the ovine-culture-positive samples were positive in the HT-J test. As similar total numbers of samples from M. avium subsp. paratuberculosis-exposed animals were positive in culture and HT-J tests in both species, and as the results of a McNemar's test were not significant, these methods probably have similar sensitivities, but the true diagnostic sensitivities of these tests are unknown. These validation data meet the consensus-based reporting standards for diagnostic test accuracy studies for paratuberculosis and the Minimum Information for Publication of Quantitative Real-Time PCR Experiments (MIQE) guidelines (S. A. Bustin et al., Clin. Chem. 55:611–622, 2009, doi:10.1373/clinchem.2008.112797). The HT-J assay has been approved for use in JD control programs in Australia and New Zealand. PMID:24352996

  18. Comparison of various primer sets for detection of Toxoplasma gondii by polymerase chain reaction in fetal tissues from naturally aborted foxes.

    PubMed

    Smielewska-Loś, E

    2003-01-01

    Tissues from 4 aborted polar foxes (3 samples of brain and 4 samples of liver) were selected for Toxoplasma gondii PCR assay. Positive results of serological tests of mothers and immunofluorescence test (IFT) of fetal organ smears were the criteria of sample selection. Five sets of primers designed from B1 gene and ITS1 sequences of T. gondii were used for detection of the parasite in fetal fox tissues. All used primer sets successfully amplified T. gondii DNA in PCR from organs which were positive by IFT. Single tube nested PCR also showed positive result from a sample negative by IFT, but this product was not confirmed. The studies showed usefullness of PCR for routine diagnosis of toxoplasmosis in carnivores.

  19. [Comparison of the Conventional Centrifuged and Filtrated Preparations in Urine Cytology].

    PubMed

    Sekita, Nobuyuki; Shimosakai, Hirofumi; Nishikawa, Rika; Sato, Hiroaki; Kouno, Hiroyoshi; Fujimura, Masaaki; Mikami, Kazuo

    2016-03-01

    The urine cytology test is one of the most important tools for the diagnosis of malignant urinary tract tumors. This test is also of great value for predicting malignancy. However, the sensitivity of this test is not high enough to screen for malignant cells. In our laboratory, we were able to attain a high sensitivity of urine cytology tests after changing the preparation method of urine samples. The differences in the cytodiagnosis between the two methods are discussed here. From January 2012 to June 2013, 2,031 urine samples were prepared using the conventional centrifuge method (C method) ; and from September 2013 to March 2015, 2,453 urine samples were prepared using the filtration method (F method) for the cytology test. When the samples included in category 4 or 5, were defined as cytological positive, the sensitivities of this test with samples prepared using the F method were significantly high compared with samples prepared using the C method (72% vs 28%, p<0.001). The number of cells on the glass slides prepared by the F method was significantly higher than that of the samples prepared by the C method (p<0.001). After introduction of the F method, the number of f alse negative cases was decreased in the urine cytology test because a larger number of cells was seen and easily detected as atypical or malignant epithelial cells. Therefore, this method has a higher sensitivity than the conventional C method as the sensitivity of urine cytology tests relies partially on the number of cells visualized in the prepared samples.

  20. Utility of urine lipoarabinomannan (LAM) in diagnosing tuberculosis and predicting mortality with and without HIV: prospective TB cohort from the Thailand Big City TB Research Network.

    PubMed

    Suwanpimolkul, Gompol; Kawkitinarong, Kamon; Manosuthi, Weerawat; Sophonphan, Jiratchaya; Gatechompol, Sivaporn; Ohata, Pirapon June; Ubolyam, Sasiwimol; Iampornsin, Thatri; Katerattanakul, Pairaj; Avihingsanon, Anchalee; Ruxrungtham, Kiat

    2017-06-01

    To evaluate the applicability and accuracy of the urine lipoarabinomannan (LAM) test in tuberculosis (TB)/HIV co-infected patients and HIV-negative patients with disseminated TB. Frozen urine samples obtained at baseline from patients in the TB research cohort with proven culture-positive TB were selected for blinded urine LAM testing. One hundred and nine patients were categorized into four groups: (1) HIV-positive patients with TB; (2) HIV-negative patients with disseminated TB; (3) HIV-negative immunocompromised patients with TB; and (4) patients with diseases other than TB. The sensitivity of urine LAM testing for culture-positive TB, specificity of urine LAM testing for patients without TB, positive predictive value (PPV), and negative predictive value (NPV) were assessed. The sensitivity of the urine LAM test in group 1 patients with a CD4 T-cell count of >100, ≤100, and ≤50 cells/mm 3 was 38.5%, 40.6%, and 45%, respectively. The specificity and PPV of the urine LAM test were >80%. The sensitivity of the test was 20% in group 2 and 12.5% in group 3, and the specificity and PPV were 100% for both groups. A positive urine LAM test result was significantly associated with death. This promising diagnostic tool could increase the yield of TB diagnosis and may predict the mortality rate of TB infection, particularly in TB/HIV co-infected patients. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

Top