Sample records for samples tested positive

  1. False-positive LSD testing in urine samples from intensive care patients.

    PubMed

    Röhrich, J; Zörntlein, S; Lotz, J; Becker, J; Kern, T; Rittner, C

    1998-09-01

    Unexpected positive results for lysergic acid diethylamide (LSD) were found in urine samples from 12 patients in an intensive care unit in a routine screening using the CEDIA DAU assay. None of these test results could be confirmed by high-performance liquid chromatography analysis, but all samples contained the mucolytic drug ambroxol. Further studies demonstrated that ambroxol exhibits a significant cross-reactivity in the CEDIA DAU LSD assay. Therefore, positive LSD results obtained with the CEDIA DAU assay have to be critically evaluated, particularly during the cold season, when infections of the respiratory tract often result in more frequent use of mucolytic medications.

  2. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    PubMed

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  3. Sample positioning in microgravity

    NASA Technical Reports Server (NTRS)

    Sridharan, Govind (Inventor)

    1991-01-01

    Repulsion forces arising from laser beams are provided to produce mild positioning forces on a sample in microgravity vacuum environments. The system of the preferred embodiment positions samples using a plurality of pulsed lasers providing opposing repulsion forces. The lasers are positioned around the periphery of a confinement area and expanded to create a confinement zone. The grouped laser configuration, in coordination with position sensing devices, creates a feedback servo whereby stable position control of a sample within microgravity environment can be achieved.

  4. Sample positioning in microgravity

    NASA Technical Reports Server (NTRS)

    Sridharan, Govind (Inventor)

    1993-01-01

    Repulsion forces arising from laser beams are provided to produce mild positioning forces on a sample in microgravity vacuum environments. The system of the preferred embodiment positions samples using a plurality of pulsed lasers providing opposing repulsion forces. The lasers are positioned around the periphery of a confinement area and expanded to create a confinement zone. The grouped laser configuration, in coordination with position sensing devices, creates a feedback servo whereby stable position control of a sample within microgravity environment can be achieved.

  5. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    PubMed Central

    2012-01-01

    Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals. PMID:22429706

  6. Simple Sample Preparation Method for Direct Microbial Identification and Susceptibility Testing From Positive Blood Cultures.

    PubMed

    Pan, Hong-Wei; Li, Wei; Li, Rong-Guo; Li, Yong; Zhang, Yi; Sun, En-Hua

    2018-01-01

    Rapid identification and determination of the antibiotic susceptibility profiles of the infectious agents in patients with bloodstream infections are critical steps in choosing an effective targeted antibiotic for treatment. However, there has been minimal effort focused on developing combined methods for the simultaneous direct identification and antibiotic susceptibility determination of bacteria in positive blood cultures. In this study, we constructed a lysis-centrifugation-wash procedure to prepare a bacterial pellet from positive blood cultures, which can be used directly for identification by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS) and antibiotic susceptibility testing by the Vitek 2 system. The method was evaluated using a total of 129 clinical bacteria-positive blood cultures. The whole sample preparation process could be completed in <15 min. The correct rate of direct MALDI-TOF MS identification was 96.49% for gram-negative bacteria and 97.22% for gram-positive bacteria. Vitek 2 antimicrobial susceptibility testing of gram-negative bacteria showed an agreement rate of antimicrobial categories of 96.89% with a minor error, major error, and very major error rate of 2.63, 0.24, and 0.24%, respectively. Category agreement of antimicrobials against gram-positive bacteria was 92.81%, with a minor error, major error, and very major error rate of 4.51, 1.22, and 1.46%, respectively. These results indicated that our direct antibiotic susceptibility analysis method worked well compared to the conventional culture-dependent laboratory method. Overall, this fast, easy, and accurate method can facilitate the direct identification and antibiotic susceptibility testing of bacteria in positive blood cultures.

  7. Evidence for false-positive results for boldenone testing of veal urine due to faecal cross-contamination during sampling.

    PubMed

    Sgoifo Rossi, C A; Arioli, F; Bassini, A; Chiesa, L M; Dell'Orto, V; Montana, M; Pompa, G

    2004-08-01

    European Directive 96/22/EC, which controls veterinary residues in animals, does not permit the presence of synthetic growth promoters in products of animal origin or in livestock. Boldenone is categorized in class A3 (growth promoters -- steroids) and is thus a banned substance. Testing of veal urine for banned substances is part of the European Union statutory programme for animals going into the food chain. In relation to this monitoring, three studies were conducted to investigate the apparent presence of the banned growth promoter boldenone in veal urine, which was suspected as being caused by interference from faecal contamination of the sample. In the first study, urine samples were collected at different times (time 0 and after 30 min) using (1) a conventional zoonotechnical apron and (2) a technique designed specifically to avoid faecal contamination ('kettle'). This resulted in samples that were, respectively, positive and negative for the presence of alpha-boldenone (alpha-BOL). In a second study, urine samples negative to alpha-BOL were collected from eight veal calves, but became positive after deliberate faecal contamination. In a third study, data obtained from the Italian RNP (Residual National Program) indicated that 18.1% of 3295 urine samples collected using the zootechnical apron were positive for alpha-BOL and 2.1% for beta-boldenone (beta-BOL), whilst of 902 samples collected using the kettle, beta-BOL was not detected in any samples and only 0.2% were positive to alpha-BOL, in concentrations lower than 2 ng ml(-1). These results further support the supposition that faecal contamination of the urine during sample collection can lead to false-positive results during boldenone analysis.

  8. Oxybuprocaine induces a false-positive response in immunochromatographic SAS Adeno Test.

    PubMed

    Hoshino, Takeshi; Takanashi, Taiji; Okada, Morio; Uchida, Sunao

    2002-04-01

    To investigate whether a solution of oxybuprocaine hydrochloride, 0.4%, results in a false-positive response in an immunochromatographic SAS Adeno Test. Experimental study. Physiologic saline and 2% lidocaine. Each chemical (100 microl) was diluted in a transport medium. Five drops (200 microl) of the resultant solution were dispensed into the round sample well of a test device. Fifteen samples were tested in each group. Ten minutes after the start of the test, a colored line in the "specimen" portion of the test membrane was visually read as positive or negative by a masked technician. No positive reaction was observed in the control groups (physiologic saline and lidocaine). A false-positive reaction was observed in six samples (33.3%) in the oxybuprocaine group. The positive rate was significantly higher in the oxybuprocaine group compared with those in control groups (P = 0.0062, Fisher's extract probability test). Oxybuprocaine may induce a false-positive reaction in an immunochromatographic SAS Adeno Test. We recommend the use of lidocaine, instead of oxybuprocaine, for local anesthesia in taking eye swabs from patients with suspected adenovirus infection.

  9. Test equality between two binary screening tests with a confirmatory procedure restricted on screen positives.

    PubMed

    Lui, Kung-Jong; Chang, Kuang-Chao

    2015-01-01

    In studies of screening accuracy, we may commonly encounter the data in which a confirmatory procedure is administered to only those subjects with screen positives for ethical concerns. We focus our discussion on simultaneously testing equality of sensitivity and specificity between two binary screening tests when only subjects with screen positives receive the confirmatory procedure. We develop four asymptotic test procedures and one exact test procedure. We derive sample size calculation formula for a desired power of detecting a difference at a given nominal [Formula: see text]-level. We employ Monte Carlo simulation to evaluate the performance of these test procedures and the accuracy of the sample size calculation formula developed here in a variety of situations. Finally, we use the data obtained from a study of the prostate-specific-antigen test and digital rectal examination test on 949 Black men to illustrate the practical use of these test procedures and the sample size calculation formula.

  10. The evaluation of a positive direct antiglobulin test (autocontrol) in pretransfusion testing revisited.

    PubMed

    Judd, W J; Barnes, B A; Steiner, E A; Oberman, H A; Averill, D B; Butch, S H

    1986-01-01

    Direct antiglobulin tests (DATs) using anti-IgG were performed on 65,049 blood samples from prospective transfusion recipients; 3570 tests (5.49%) were positive. Using criteria published previously (primarily excluding patients not transfused within the preceding 14 days), 778 samples from other than neonatal patients were selected for further evaluation. Eluates that did not react were obtained on 518 (66.6%) of these samples. Warm-reactive autoantibodies were apparent in 192 eluates, while 16 contained drug-related antibodies, anti-A or anti-B from prior transfusion with ABO mismatched blood components, or anti-D passively acquired from immune serum globulin. Fifty-two eluates contained alloantibodies; however, in only six of these cases did the corresponding serum lack unexpected alloantibodies, as determined by routine pretransfusion studies. Three additional weakly reactive clinically significant alloantibodies were detected solely through additional serum tests performed on DAT-positive samples. On the basis of these findings, the DAT had a low predictive value when used to detect the early manifestations of an immune response to recently transfused red cells. Elimination of the autocontrol from routine pretransfusion testing, therefore, carries minimal risk to patients yet will undoubtedly contribute to the containment of health care costs. Moreover, the risk is lower than that associated with the elimination of the antiglobulin crossmatch.

  11. Testing predictive models of positive and negative affect with psychosocial, acculturation, and coping variables in a multiethnic undergraduate sample.

    PubMed

    Kuo, Ben Ch; Kwantes, Catherine T

    2014-01-01

    Despite the prevalence and popularity of research on positive and negative affect within the field of psychology, there is currently little research on affect involving the examination of cultural variables and with participants of diverse cultural and ethnic backgrounds. To the authors' knowledge, currently no empirical studies have comprehensively examined predictive models of positive and negative affect based specifically on multiple psychosocial, acculturation, and coping variables as predictors with any sample populations. Therefore, the purpose of the present study was to test the predictive power of perceived stress, social support, bidirectional acculturation (i.e., Canadian acculturation and heritage acculturation), religious coping and cultural coping (i.e., collective, avoidance, and engagement coping) in explaining positive and negative affect in a multiethnic sample of 301 undergraduate students in Canada. Two hierarchal multiple regressions were conducted, one for each affect as the dependent variable, with the above described predictors. The results supported the hypotheses and showed the two overall models to be significant in predicting affect of both kinds. Specifically, a higher level of positive affect was predicted by a lower level of perceived stress, less use of religious coping, and more use of engagement coping in dealing with stress by the participants. Higher level of negative affect, however, was predicted by a higher level of perceived stress and more use of avoidance coping in responding to stress. The current findings highlight the value and relevance of empirically examining the stress-coping-adaptation experiences of diverse populations from an affective conceptual framework, particularly with the inclusion of positive affect. Implications and recommendations for advancing future research and theoretical works in this area are considered and presented.

  12. Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    PubMed Central

    2010-01-01

    Background Malaria rapid diagnostic tests (RDTs) are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution) or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands) showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74%) RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20), and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs). Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness) of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results. PMID:20650003

  13. Impaired limb position sense after stroke: a quantitative test for clinical use.

    PubMed

    Carey, L M; Oke, L E; Matyas, T A

    1996-12-01

    A quantitative measure of wrist position sense was developed to advance clinical measurement of proprioceptive limb sensibility after stroke. Test-retest reliability, normative standards, and ability to discriminate impaired and unimpaired performance were investigated. Retest reliability was assessed over three sessions, and a matched-pairs study compared stroke and unimpaired subjects. Both wrists were tested, in counterbalanced order. Patients were tested in hospital-based rehabilitation units. Reliability was investigated on a consecutive sample of 35 adult stroke patients with a range of proprioceptive discrimination abilities and no evidence of neglect. A consecutive sample of 50 stroke patients and convenience sample of 50 healthy volunteers, matched for age, sex, and hand dominance, were tested in the normative-discriminative study. Age and sex were representative of the adult stroke population. The test required matching of imposed wrist positions using a pointer aligned with the axis of movement and a protractor scale. The test was reliable (r = .88 and .92) and observed changes of 8 degrees can be interpreted, with 95% confidence, as genuine. Scores of healthy volunteers ranged from 3.1 degrees to 10.9 degrees average error. The criterion of impairment was conservatively defined as 11 degrees (+/-4.8 degrees) average error. Impaired and unimpaired performance were well differentiated. Clinicians can confidently and quantitatively sample one aspect of proprioceptive sensibility in stroke patients using the wrist position sense test. Development of tests on other joints using the present approach is supported by our findings.

  14. Perfectionism, Performance, and State Positive Affect and Negative Affect after a Classroom Test

    ERIC Educational Resources Information Center

    Flett, Gordon L.; Blankstein, Kirk R.; Hewitt, Paul L.

    2009-01-01

    The current study examined the associations among trait dimensions of perfectionism, test performance, and levels of positive and negative affect after taking a test. A sample of 92 female university students completed the Multidimensional Perfectionism Scale one week prior to an actual class test. Measures of positive affect and negative affect…

  15. Factors affecting faecal immunochemical test positive rates: demographic, pathological, behavioural and environmental variables.

    PubMed

    Symonds, Erin L; Osborne, Joanne M; Cole, Stephen R; Bampton, Peter A; Fraser, Robert J L; Young, Graeme P

    2015-12-01

    Positive rates in faecal immunochemical test (FIT)-based colorectal cancer screening programmes vary, suggesting that differences between programmes may affect test results. We examined whether demographic, pathological, behavioural, and environmental factors affected haemoglobin concentration and positive rates where samples are mailed. A retrospective cohort study; 34,298 collection devices were sent, over five years, to screening invitees (median age 60.6). Participant demographics, temperature on sample postage day, and previous screening were recorded. Outcomes from colonoscopy performed within a year following FIT were collected. Multivariate logistic regression identified significant predictors of test positivity. Higher positive rate was independently associated with male gender, older age, lower socioeconomic status, and distally located neoplasia, and negatively associated with previous screening (p < 0.05). Older males had higher faecal haemoglobin concentrations and were less likely to have a false positive result at colonoscopy (p < 0.05). High temperature on the sample postage day was associated with reduced haemoglobin concentration and positivity rate (26-35℃: Odds ratio 0.78, 95% confidence interval 0.66-0.93), but was not associated with missed significant neoplasia at colonoscopy (p > 0.05). Haemoglobin concentrations, and therefore FIT positivity, were affected by factors that vary between screening programmes. Participant demographics and high temperature at postage had significant effects. The impact of temperature could be reduced by seasonal scheduling of invitations. The importance of screening, and following up positive test results, particularly in older males, should be promoted. © The Author(s) 2015.

  16. PCR-based verification of positive rapid diagnostic tests for intestinal protozoa infections with variable test band intensity.

    PubMed

    Becker, Sören L; Müller, Ivan; Mertens, Pascal; Herrmann, Mathias; Zondie, Leyli; Beyleveld, Lindsey; Gerber, Markus; du Randt, Rosa; Pühse, Uwe; Walter, Cheryl; Utzinger, Jürg

    2017-10-01

    Stool-based rapid diagnostic tests (RDTs) for pathogenic intestinal protozoa (e.g. Cryptosporidium spp. and Giardia intestinalis) allow for prompt diagnosis and treatment in resource-constrained settings. Such RDTs can improve individual patient management and facilitate population-based screening programmes in areas without microbiological laboratories for confirmatory testing. However, RDTs are difficult to interpret in case of 'trace' results with faint test band intensities and little is known about whether such ambiguous results might indicate 'true' infections. In a longitudinal study conducted in poor neighbourhoods of Port Elizabeth, South Africa, a total of 1428 stool samples from two cohorts of schoolchildren were examined on the spot for Cryptosporidium spp. and G. intestinalis using an RDT (Crypto/Giardia DuoStrip; Coris BioConcept). Overall, 121 samples were positive for G. intestinalis and the RDT suggested presence of cryptosporidiosis in 22 samples. After a storage period of 9-10 months in cohort 1 and 2-3 months in cohort 2, samples were subjected to multiplex PCR (BD Max™ Enteric Parasite Panel, Becton Dickinson). Ninety-three percent (112/121) of RDT-positive samples for G. intestinalis were confirmed by PCR, with a correlation between RDT test band intensity and quantitative pathogen load present in the sample. For Cryptosporidium spp., all positive RDTs had faintly visible lines and these were negative on PCR. The performance of the BD Max™ PCR was nearly identical in both cohorts, despite the prolonged storage at disrupted cold chain conditions in cohort 1. The Crypto/Giardia DuoStrip warrants further validation in communities with a high incidence of diarrhoea. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Direct detection of Trichomonas vaginalis virus in Trichomonas vaginalis positive clinical samples from the Netherlands.

    PubMed

    Jehee, Ivo; van der Veer, Charlotte; Himschoot, Michelle; Hermans, Mirjam; Bruisten, Sylvia

    2017-12-01

    Trichomonas vaginalis is the most common sexually transmitted parasitical infection worldwide. T. vaginalis can carry a virus: Trichomonas vaginalis virus (TVV). To date, four TVV species have been described. Few studies have investigated TVV prevalence and its clinical importance. We have developed a nested reverse-transcriptase PCR, with novel, type specific primers to directly detect TVV RNA in T. vaginalis positive clinical samples. A total of 119T. vaginalis positive clinical samples were collected in Amsterdam and "s-Hertogenbosch, the Netherlands, from 2012 to 2016. For all samples T. vaginalis was genotyped using multi-locus sequence typing. The T. vaginalis positive samples segregated into a two-genotype population: type I (n=64) and type II (n=55). All were tested for TVV with the new TVV PCR. We detected 3 of the 4 TVV species. Sequencing of the amplified products showed high homology with published TVV genomes (82-100%). Half of the T. vaginalis clinical samples (n=60, 50.4%) were infected with one or more TVV species, with a preponderance for TVV infections in T. vaginalis type I (n=44, 73.3%). Clinical data was available for a subset of samples (n=34) and we observed an association between testing positive for (any) TVV and reporting urogenital symptoms (p=0.023). The nested RT-PCR allowed for direct detection of TVV in T. vaginalis positive clinical samples. This may be helpful in studies and clinical settings, since T. vaginalis disease and/or treatment outcome may be influenced by the protozoa"s virus. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Evaluation of rapid diagnostic test kits for feline leukemia virus infection using samples from naturally infected cats.

    PubMed

    Liu, Jiayou; O'Connor, Thomas; Beall, Melissa; Chandrashekar, Ramaswamy; Lappin, Michael

    2016-01-01

    Feline leukemia virus (FeLV) is a potentially life-threatening oncogenic retrovirus. The p27 viral core protein is produced by the virus in infected feline cells, is found in the cytoplasm in several blood cells and can be free in the serum and plasma. ELISA or particle-based immunoassay are commonly used to detect the presence of the p27 core protein in samples obtained from blood. The objective of this study was to compare the performance of several in-clinic tests: the SNAP Feline Triple Test (IDEXX Laboratories), the WITNESS FeLV-FIV Test (Zoetis) and the VetScan Feline FeLV/FIV Rapid Test (Abaxis). The sample population (100 positive, 105 negative samples) consisted of serum and plasma samples submitted to IDEXX's worldwide reference laboratory for feline retrovirus testing. Virus isolation and reverse transcriptase PCR results were not available and so samples were judged to be positive or negative based on the results of the ViraCHEK FeLV (Zoetis) microtiter plate assay. The percentage of samples positive and negative for FeLV p27 antigen using the three in-clinic tests compared with the ViraCHEK method were as follows: IDEXX Feline Triple (positive 98.0%, negative 100%); Zoetis WITNESS (positive 79.0%, negative 97.1%); Abaxis VetScan (positive 73.0%, negative 97.1%). The SNAP Feline Triple Test demonstrated a high level of agreement for FeLV-positive and FeLV-negative samples when assessed in this model. Results of FeLV assays can vary among tests.

  19. Comparison of five diagnostic tests for Giardia duodenalis in fecal samples from young dogs.

    PubMed

    Uehlinger, Fabienne D; Naqvi, S Ali; Greenwood, Spencer J; McClure, J Trenton; Conboy, Gary; O'Handley, Ryan; Barkema, Herman W

    2017-09-15

    Five diagnostic tests were compared for the diagnosis of Giardia duodenalis in fecal samples of young dogs. Fecal samples were collected from 136 healthy dogs <1year old and examined using immunofluorescence antibody microscopy (IFA) after sucrose gradient centrifugation, zinc sulfate centrifugal flotation technique (ZSCT), SNAP ® Giardia test, and ProSpecT ® Giardia EZ Microplate assay. In addition, polymerase chain reaction (PCR) of the 16S rRNA gene was performed. Kappa (κ) statistic was calculated to assess diagnostic agreement between the IFA and each test. Using the IFA as the gold standard, the relative sensitivity and specificity of each test were determined. Subsequently, a Bayesian approach was used to estimate the sensitivity and specificity of each test in comparison to the IFA results. Giardia duodenalis was detected in 41% of the samples examined by IFA. The ZSCT resulted in 37% of positive samples, with a relative sensitivity and specificity of 86 and 98%, respectively. The SNAP ® Giardia test was positive in 40% of the samples, with a relative sensitivity and specificity of 91 and 96%, respectively. The ProSpecT ® test was positive in 51% of the samples, with a relative sensitivity and specificity of 100 and 83%, respectively. The relative sensitivity and specificity for PCR were 58 and 56%, respectively, with 55% of samples being PCR-positive. While the sensitivity and specificity estimates of each test in comparison to the IFA changed when using a Bayesian approach, the conclusions remained the same. While the ProSpecT ® test was the most sensitive test in this study, it is not designed for dogs and more costly than the other tests. The SNAP ® Giardia test performed similar to the ZSCT but may be more favorable because it is fast and easy to perform. Performance of the PCR was poor and the benefit of PCR may be in determining genotypes for evaluating zoonotic transfer between dogs and humans. Copyright © 2017 Elsevier B.V. All rights

  20. Estimation of sample size and testing power (Part 3).

    PubMed

    Hu, Liang-ping; Bao, Xiao-lei; Guan, Xue; Zhou, Shi-guo

    2011-12-01

    This article introduces the definition and sample size estimation of three special tests (namely, non-inferiority test, equivalence test and superiority test) for qualitative data with the design of one factor with two levels having a binary response variable. Non-inferiority test refers to the research design of which the objective is to verify that the efficacy of the experimental drug is not clinically inferior to that of the positive control drug. Equivalence test refers to the research design of which the objective is to verify that the experimental drug and the control drug have clinically equivalent efficacy. Superiority test refers to the research design of which the objective is to verify that the efficacy of the experimental drug is clinically superior to that of the control drug. By specific examples, this article introduces formulas of sample size estimation for the three special tests, and their SAS realization in detail.

  1. 30 CFR 71.208 - Bimonthly sampling; designated work positions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Bimonthly sampling; designated work positions... COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Sampling Procedures § 71.208 Bimonthly sampling; designated work positions. (a) Each...

  2. Comparison of Clark's presence-absence test and the membrane filter method for coliform detection in potable water samples.

    PubMed Central

    Pipes, W O; Minnigh, H A; Moyer, B; Troy, M A

    1986-01-01

    A total of 2,601 water samples from six different water systems were tested for coliform bacteria by Clark's presence-absence (P-A) test and by the membrane filter (MF) method. There was no significant difference in the fraction of samples positive for coliform bacteria for any of the systems tested. It was concluded that the two tests are equivalent for monitoring purposes. However, 152 samples were positive for coliform bacteria by the MF method but negative by the P-A test, and 132 samples were positive by the P-A test but negative by the MF method. Many of these differences for individual samples can be explained by random dispersion of bacteria in subsamples when the coliform density is low. However, 15 samples had MF counts greater than 3 and gave negative P-A results. The only apparent explanation for most of these results is that coliform bacteria were present in the P-A test bottles but did not produce acid and gas. Two other studies have reported more samples positive by Clark's P-A test than by the MF method. PMID:3532953

  3. Rapid microbiological screening for tuberculosis in HIV-positive patients on the first day of acute hospital admission by systematic testing of urine samples using Xpert MTB/RIF: a prospective cohort in South Africa.

    PubMed

    Lawn, Stephen D; Kerkhoff, Andrew D; Burton, Rosie; Schutz, Charlotte; van Wyk, Gavin; Vogt, Monica; Pahlana, Pearl; Nicol, Mark P; Meintjes, Graeme

    2015-08-14

    Autopsy studies of HIV/AIDS-related hospital deaths in sub-Saharan Africa reveal frequent failure of pre-mortem diagnosis of tuberculosis (TB), which is found in 34-64 % of adult cadavers. We determined the overall prevalence and predictors of TB among consecutive unselected HIV-positive adults requiring acute hospital admission and the comparative diagnostic yield obtained by screening urine and sputum samples obtained on day 1 of admission with Xpert MTB/RIF (Xpert). To determine overall TB prevalence accurately, comprehensive clinical sampling (sputum, urine, blood plus other relevant samples) was done and TB was defined by detection of Mycobacterium tuberculosis in any sample using Xpert and/or mycobacterial liquid culture. To evaluate a rapid screening strategy, we compared the diagnostic yield of Xpert testing sputum samples and urine samples obtained with assistance from a respiratory study nurse in the first 24 h of admission. Unselected HIV-positive acute adult new medical admissions (n = 427) who were not receiving TB treatment were enrolled irrespective of clinical presentation or symptom profile. From 2,391 cultures and Xpert tests done (mean, 5.6 tests/patient) on 1,745 samples (mean, 4.1 samples/patient), TB was diagnosed in 139 patients (median CD4 cell count, 80 cells/μL). TB prevalence was very high (32.6 %; 95 % CI, 28.1-37.2 %; 139/427). However, patient symptoms and risk factors were poorly predictive for TB. Overall, ≥1 non-respiratory sample(s) tested positive in 115/139 (83 %) of all TB cases, including positive blood cultures in 41/139 (29.5 %) of TB cases. In the first 24 h of admission, sputum (spot and/or induced samples) and urine were obtainable from 37.0 % and 99.5 % of patients, respectively (P <0.001). From these, the proportions of total TB cases (n = 139) that were diagnosed by Xpert testing sputum, urine or both sputum and urine combined within the first 24 h were 39/139 (28.1 %), 89/139 (64.0 %) and 108/139 (77.7 %) cases

  4. Variations in the detection of anti-PEDV antibodies in serum samples using three diagnostic tests - short communication.

    PubMed

    Plut, Jan; Toplak, Ivan; Štukelj, Marina

    2018-06-01

    Over the last few years several porcine epidemic diarrhoea (PED) outbreaks have been discovered in Europe including the first PED case in Slovenia in January 2015. The aim of this study was to determine when PED virus (PEDV) infection started in Slovenia. Serum samples collected between 2012 and 2016 were tested. Three hundred and seventy-five serum samples were collected from 132 Slovenian small, one-site pig farms. Samples were tested for PEDV antibodies utilising three different serological methods: commercially-available indirect ELISA, in-house blocking ELISA test and Immunoperoxidase Monolayer Assay (IPMA) test. One hundred and seventy (45.33%) tested samples were found positive by the commercially-available ELISA test kit, and 10 (5.68%) of these 170 samples found positive were positive by the in-house blocking ELISA. Only these 10 samples were collected from a farm where clinical signs of PED infection had been observed and PEDV was confirmed by RT-PCR methodology; the other 160 samples were collected randomly. Thirty-two samples with the highest S/P value obtained with the commercial ELISA were all negative with IPMA. Reasons for the high variance in the results obtained remain unclear; more research is required to ensure higher sensitivity and specificity in terms of PEDV antibody tests and other PED diagnostic methods.

  5. Optical sample-position sensing for electrostatic levitation

    NASA Technical Reports Server (NTRS)

    Sridharan, G.; Chung, S.; Elleman, D.; Whim, W. K.

    1989-01-01

    A comparative study is conducted for optical position-sensing techniques applicable to micro-G conditions sample-levitation systems. CCD sensors are compared with one- and two-dimensional position detectors used in electrostatic particle levitation. In principle, the CCD camera method can be improved from current resolution levels of 200 microns through the incorporation of a higher-pixel device and more complex digital signal processor interface. Nevertheless, the one-dimensional position detectors exhibited superior, better-than-one-micron resolution.

  6. Multiple diagnostic tests to identify cattle with Bovine viral diarrhea virus and duration of positive test results in persistently infected cattle

    PubMed Central

    Fulton, Robert W.; Hessman, Bill E.; Ridpath, Julia F.; Johnson, Bill J.; Burge, Lurinda J.; Kapil, Sanjay; Braziel, Barbara; Kautz, Kira; Reck, Amy

    2009-01-01

    Several tests for Bovine viral diarrhea virus (BVDV) were applied to samples collected monthly from December 20, 2005, through November 27, 2006 (day 0 to day 342) from 12 persistently infected (PI) cattle with BVDV subtypes found in US cattle: BVDV-1a, BVDV-1b, and BVDV-2a. The samples included clotted blood for serum, nasal swabs, and fresh and formalin-fixed ear notches. The tests were as follows: titration of infectious virus in serum and nasal swabs; antigen-capture (AC) enzyme-linked immunosorbent assay (ELISA), or ACE, on serum, nasal swabs, and fresh ear notches; gel-based polymerase chain reaction (PCR) testing of serum, nasal swabs, and fresh ear notches; immunohistochemical (IHC) testing of formalin-fixed ear notches; and serologic testing for BVDV antibodies in serum. Of the 12 animals starting the study, 3 died with mucosal disease. The ACE and IHC tests on ear notches had positive results throughout the study, as did the ACE and PCR tests on serum. There was detectable virus in nasal swabs from all the cattle throughout the study except for a few samples that were toxic to cell cultures. The serum had a virus titer ≥ log10 1.60 in all samples from all the cattle except for 3 collections from 1 animal. Although there were several equivocal results, the PCR test most often had positive results. The BVDV antibodies were due to vaccination or exposure to heterologous strains and did not appear to interfere with any BVDV test. These findings illustrate that PI cattle may be identified by several tests, but differentiation of PI cattle from cattle with acute BVDV infection requires additional testing, especially of blood samples and nasal swabs positive on initial testing. Also, calves PI with BVDV are continual shedders of infectious virus, as shown by the infectivity of nasal swabs over the 11-mo study. PMID:19436580

  7. [Mes differ by positioning: empirical testing of decentralized dynamics of the self].

    PubMed

    Mizokami, Shinichi

    2013-10-01

    The present study empirically tested the conceptualization of the decentralized dynamics of the self proposed by Hermans & Kempen (1993), which they developed theoretically and from clinical cases, not from large samples of empirical data. They posited that worldviews and images of the self could vary by positioning even in the same individual, and denied that the ego was an omniscient entity that knew and controlled all aspects of the self (centralized ego). Study 1 tested their conceptualization empirically with 47 university students in an experimental group and 17 as a control group. The results showed that the scores on the Rosenberg's self-esteem scale and images of the Mes in the experimental group significantly varied by positioning, but those in the control group did not. Similar results were found in Study 2 with a sample of 120 university students. These results empirically supported the conceptualization of the decentralized dynamics of the self.

  8. Decision Models for Determining the Optimal Life Test Sampling Plans

    NASA Astrophysics Data System (ADS)

    Nechval, Nicholas A.; Nechval, Konstantin N.; Purgailis, Maris; Berzins, Gundars; Strelchonok, Vladimir F.

    2010-11-01

    Life test sampling plan is a technique, which consists of sampling, inspection, and decision making in determining the acceptance or rejection of a batch of products by experiments for examining the continuous usage time of the products. In life testing studies, the lifetime is usually assumed to be distributed as either a one-parameter exponential distribution, or a two-parameter Weibull distribution with the assumption that the shape parameter is known. Such oversimplified assumptions can facilitate the follow-up analyses, but may overlook the fact that the lifetime distribution can significantly affect the estimation of the failure rate of a product. Moreover, sampling costs, inspection costs, warranty costs, and rejection costs are all essential, and ought to be considered in choosing an appropriate sampling plan. The choice of an appropriate life test sampling plan is a crucial decision problem because a good plan not only can help producers save testing time, and reduce testing cost; but it also can positively affect the image of the product, and thus attract more consumers to buy it. This paper develops the frequentist (non-Bayesian) decision models for determining the optimal life test sampling plans with an aim of cost minimization by identifying the appropriate number of product failures in a sample that should be used as a threshold in judging the rejection of a batch. The two-parameter exponential and Weibull distributions with two unknown parameters are assumed to be appropriate for modelling the lifetime of a product. A practical numerical application is employed to demonstrate the proposed approach.

  9. Reveal Salmonella 2.0 test for detection of Salmonella spp. in foods and environmental samples. Performance Tested Method 960801.

    PubMed

    Hoerner, Rebecca; Feldpausch, Jill; Gray, R Lucas; Curry, Stephanie; Islam, Zahidul; Goldy, Tim; Klein, Frank; Tadese, Theodros; Rice, Jennifer; Mozola, Mark

    2011-01-01

    Reveal Salmonella 2.0 is an improved version of the original Reveal Salmonella lateral flow immunoassay and is applicable to the detection of Salmonella enterica serogroups A-E in a variety of food and environmental samples. A Performance Tested Method validation study was conducted to compare performance of the Reveal 2.0 method with that of the U.S. Department of Agriculture-Food Safety and Inspection Service or U.S. Food and Drug Administration/Bacteriological Analytical Manual reference culture methods for detection of Salmonella spp. in chicken carcass rinse, raw ground turkey, raw ground beef, hot dogs, raw shrimp, a ready-to-eat meal product, dry pet food, ice cream, spinach, cantaloupe, peanut butter, stainless steel surface, and sprout irrigation water. In a total of 17 trials performed internally and four trials performed in an independent laboratory, there were no statistically significant differences in performance of the Reveal 2.0 and reference culture procedures as determined by Chi-square analysis, with the exception of one trial with stainless steel surface and one trial with sprout irrigation water where there were significantly more positive results by the Reveal 2.0 method. Considering all data generated in testing food samples using enrichment procedures specifically designed for the Reveal method, overall sensitivity of the Reveal method relative to the reference culture methods was 99%. In testing environmental samples, sensitivity of the Reveal method relative to the reference culture method was 164%. For select foods, use of the Reveal test in conjunction with reference method enrichment resulted in overall sensitivity of 92%. There were no unconfirmed positive results on uninoculated control samples in any trials for specificity of 100%. In inclusivity testing, 102 different Salmonella serovars belonging to serogroups A-E were tested and 99 were consistently positive in the Reveal test. In exclusivity testing of 33 strains of non

  10. Positive Skin Test or Specific IgE to Penicillin Does Not Reliably Predict Penicillin Allergy.

    PubMed

    Tannert, Line Kring; Mortz, Charlotte Gotthard; Skov, Per Stahl; Bindslev-Jensen, Carsten

    According to guidelines, patients are diagnosed with penicillin allergy if skin test (ST) result or specific IgE (s-IgE) to penicillin is positive. However, the true sensitivity and specificity of these tests are presently not known. To investigate the clinical relevance of a positive ST result and positive s-IgE and to study the reproducibility of ST and s-IgE. A sample of convenience of 25 patients with positive penicillin ST results, antipenicillin s-IgE results, or both was challenged with their culprit penicillin. Further 19 patients were not challenged, but deemed allergic on the basis of a recent anaphylactic reaction or delayed reactions to skin testing. Another sample of convenience of 18 patients, 17 overlapping with the 25 challenged, with initial skin testing and s-IgE (median, 25; range, 3-121), months earlier (T -1 ), was repeat skin tested and had s-IgE measured (T 0 ), and then skin tested and had s-IgE measured 4 weeks later (T 1 ). Only 9 (36%) of 25 were challenge positive. There was an increased probability of being penicillin allergic if both ST result and s-IgE were positive at T 0 . Positive ST result or positive s-IgE alone did not predict penicillin allergy. Among the 18 patients repeatedly tested, 46.2% (12 of 25) of positive ST results at T -1 were reproducibly positive at T 0 . For s-IgE, 54.2% (14 of 24) positive measurements were still positive at T 0 and 7 converted to positive at T 1 . The best predictor for a clinically significant (IgE-mediated) penicillin allergy is a combination of a positive case history with simultaneous positive ST result and s-IgE or a positive challenge result. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  11. 30 CFR 15.5 - Test samples.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Test samples. 15.5 Section 15.5 Mineral... § 15.5 Test samples. (a) Submission of test samples. (1) The applicant shall not submit explosives or... magazine for at least 30 days before gallery tests are conducted. ...

  12. 30 CFR 15.5 - Test samples.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Test samples. 15.5 Section 15.5 Mineral... § 15.5 Test samples. (a) Submission of test samples. (1) The applicant shall not submit explosives or... magazine for at least 30 days before gallery tests are conducted. ...

  13. 30 CFR 15.5 - Test samples.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Test samples. 15.5 Section 15.5 Mineral... § 15.5 Test samples. (a) Submission of test samples. (1) The applicant shall not submit explosives or... magazine for at least 30 days before gallery tests are conducted. ...

  14. Steady-State Vacuum Ultraviolet Exposure Facility With Automated Lamp Calibration and Sample Positioning Fabricated

    NASA Technical Reports Server (NTRS)

    Sechkar, Edward A.; Steuber, Thomas J.; Banks, Bruce A.; Dever, Joyce A.

    2000-01-01

    The Next Generation Space Telescope (NGST) will be placed in an orbit that will subject it to constant solar radiation during its planned 10-year mission. A sunshield will be necessary to passively cool the telescope, protecting it from the Sun s energy and assuring proper operating temperatures for the telescope s instruments. This sunshield will be composed of metalized polymer multilayer insulation with an outer polymer membrane (12 to 25 mm in thickness) that will be metalized on the back to assure maximum reflectance of sunlight. The sunshield must maintain mechanical integrity and optical properties for the full 10 years. This durability requirement is most challenging for the outermost, constantly solar-facing polymer membrane of the sunshield. One of the potential threats to the membrane material s durability is from vacuum ultraviolet (VUV) radiation in wavelengths below 200 nm. Such radiation can be absorbed in the bulk of these thin polymer membrane materials and degrade the polymer s optical and mechanical properties. So that a suitable membrane material can be selected that demonstrates durability to solar VUV radiation, ground-based testing of candidate materials must be conducted to simulate the total 10- year VUV exposure expected during the Next Generation Space Telescope mission. The Steady State Vacuum Ultraviolet exposure facility was designed and fabricated at the NASA Glenn Research Center at Lewis Field to provide unattended 24-hr exposure of candidate materials to VUV radiation of 3 to 5 times the Sun s intensity in the wavelength range of 115 to 200 nm. The facility s chamber, which maintains a pressure of approximately 5 10(exp -6) torr, is divided into three individual exposure cells, each with a separate VUV source and sample-positioning mechanism. The three test cells are separated by a water-cooled copper shield plate assembly to minimize thermal effects from adjacent test cells. Part of the interior sample positioning mechanism of one

  15. On two-sample McNemar test.

    PubMed

    Xiang, Jim X

    2016-01-01

    Measuring a change in the existence of disease symptoms before and after a treatment is examined for statistical significance by means of the McNemar test. When comparing two treatments, Feuer and Kessler (1989) proposed a two-sample McNemar test. In this article, we show that this test usually inflates the type I error in the hypothesis testing, and propose a new two-sample McNemar test that is superior in terms of preserving type I error. We also make the connection between the two-sample McNemar test and the test statistic for the equal residual effects in a 2 × 2 crossover design. The limitations of the two-sample McNemar test are also discussed.

  16. Characteristics of the LacTek test as applied to tissue samples: assessment of performance using incurred field samples.

    PubMed

    Mitchell, J M; McNab, W B; Yee, A J; Griffiths, M W; McEwen, S A; Spilsbury, L; Boison, J O

    1998-08-01

    The Lactek test, marketed for antimicrobial residue detection in milk, was validated for the detection of antimicrobial residues in tissues. A previous study found that the LacTek test could confidently identify tissue samples spiked with antimicrobial residues. However, the test could not reliably distinguish violative from nonviolative spiked samples relative to Canadian maximum residue limits (MRLs). The objectives of this study were to assess and compare the performance of the LacTek tests for beta-lactams, tetracyclines, gentamicin, and sulfamethazine on samples containing naturally incurred residues by running the test in parallel with the standard microbial inhibition test (MIT) presently used for the routine testing of tissues at our facility and to assess the agreement with high pressure liquid chromatographic (HPLC) determinative methods. Parallel testing with the official MIT found that the Lactek tests could be confidently used for testing tissue samples containing incurred residues. Among 1,008 MIT-positive samples, the LacTek test found that 90% contained beta-lactams and/or tetracyclines. A further 7.3% of violative residues could not be identified to an antimicrobial class. In addition, 9% of samples testing negative on the MIT were found to contain an antimicrobial residue by the LacTek tests. Comparative testing with HPLC methods found that there was very good agreement between the two tests and that most violations were due to penicillin G and oxytetracycline. Although the LacTek test cannot be used to distinguish violative from nonviolative residue levels, it does offer several advantages over the present MIT. These include speed, ease of use, the ability to identify residues to a specific class, and an improved sensitivity at the MRL level for the most commonly found antimicrobials in tissue.

  17. Positive cell-free fetal DNA testing for trisomy 13 reveals confined placental mosaicism.

    PubMed

    Hall, April L; Drendel, Holli M; Verbrugge, Jennifer L; Reese, Angela M; Schumacher, Katherine L; Griffith, Christopher B; Weaver, David D; Abernathy, Mary P; Litton, Christian G; Vance, Gail H

    2013-09-01

    We report on a case in which cell-free fetal DNA was positive for trisomy 13 most likely due to confined placental mosaicism. Cell-free fetal DNA testing analyzes DNA derived from placental trophoblast cells and can lead to incorrect results that are not representative of the fetus. We sought to confirm commercial cell-free fetal DNA testing results by chorionic villus sampling and amniocentesis. These results were followed up by postnatal chromosome analysis of cord blood and placental tissue. First-trimester cell-free fetal DNA test results were positive for trisomy 13. Cytogenetic analysis of chorionic villus sampling yielded a mosaic karyotype of 47,XY,+13[10]/46,XY[12]. G-banded analysis of amniotic fluid was normal, 46,XY. Postnatal cytogenetic analysis of cord blood was normal. Karyotyping of tissues from four quadrants of the placenta demonstrated mosaicism for trisomy 13 in two of the quadrants and a normal karyotype in the other two. Our case illustrates several important aspects of this new testing methodology: that cell-free fetal DNA may not be representative of the fetal karyotype; that follow-up with diagnostic testing of chorionic villus sampling and/or amniotic fluid for abnormal test results should be performed; and that pretest counseling regarding the full benefits, limitations, and possible testing outcomes of cell-free fetal DNA screening is important.

  18. Classification of bacterial samples as negative or positive for a UTI and antibiogram using surface enhanced Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Kastanos, Evdokia; Hadjigeorgiou, Katerina; Kyriakides, Alexandros; Pitris, Costas

    2011-03-01

    Urinary tract infection (UTI) diagnosis requires an overnight culture to identify a sample as positive or negative for a UTI. Additional cultures are required to identify the pathogen responsible for the infection and to test its sensitivity to antibiotics. A rise in ineffective treatments, chronic infections, rising health care costs and antibiotic resistance are some of the consequences of this prolonged waiting period of UTI diagnosis. In this work, Surface Enhanced Raman Spectroscopy (SERS) is used for classifying bacterial samples as positive or negative for UTI. SERS spectra of serial dilutions of E.coli bacteria, isolated from a urine culture, were classified as positive (105-108 cells/ml) or negative (103-104 cells/ml) for UTI after mixing samples with gold nanoparticles. A leave-one-out cross validation was performed using the first two principal components resulting in the correct classification of 82% of all samples. Sensitivity of classification was 88% and specificity was 67%. Antibiotic sensitivity testing was also done using SERS spectra of various species of gram negative bacteria collected 4 hours after exposure to antibiotics. Spectral analysis revealed clear separation between the spectra of samples exposed to ciprofloxacin (sensitive) and amoxicillin (resistant). This study can become the basis for identifying urine samples as positive or negative for a UTI and determining their antibiogram without requiring an overnight culture.

  19. The effect of sample storage on the performance and reproducibility of the galactomannan EIA test.

    PubMed

    Kimpton, George; White, P Lewis; Barnes, Rosemary A

    2014-08-01

    Galactomannan enzyme immune assay (GM EIA) is a nonculture test for detecting invasive aspergillosis (IA) forming a key part of diagnosis and management. Recent reports have questioned the reproducibility of indices after sample storage. To investigate this, 198 serum samples (72 from cases and 126 from controls) and 61 plasma samples (24 from cases and 37 from controls), initially tested between 2010 and 2013, were retested to determine any change in index. Data were also collected on circulatory protein levels for false-positive serum samples. Serum indices significantly declined on retesting (median: initial, 0.50, retest, 0.23; P < 0.0001). This was shown to be diagnosis dependent as the decline was apparent on retesting of control samples (median: initial 0.50, retest 0.12; P < 0.0001), but was not evident with case samples (median: initial, 0.80, retest, 0.80; P = 0.724). Plasma samples showed little change on reanalysis after long-term storage at 4°C. Retesting after freezing showed a decrease in index values for controls (median: initial 0.40, retest 0.26; P = 0.0505), but no significant change in cases. Circulatory proteins showed a correlation between serum albumin concentration and difference in index value on retesting. Overall, this study suggests that a lack of reproducibility in GM EIA positivity is only significant when disease is absent. Retesting after freezing helps to differentiate false-positive GM EIA results and, with consecutive positivity, could help to improve accuracy in predicting disease status. The freezing of samples prior to testing could potentially reduce false-positivity rates and the need to retest. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Exploring the Legionella pneumophila positivity rate in hotel water samples from Antalya, Turkey.

    PubMed

    Sepin Özen, Nevgün; Tuğlu Ataman, Şenay; Emek, Mestan

    2017-05-01

    The genus Legionella is a fastidious Gram-negative bacteria widely distributed in natural waters and man made water supply systems. Legionella pneumophila is the aetiological agent of approximately 90% of reported Legionellosis cases, and serogroup 1 is the most frequent cause of infections. Legionnaires' disease is often associated with travel and continues to be a public health concern at present. The correct water management quality practices and rapid methods for analyzing Legionella species in environmental water is a key point for the prevention of Legionnaires' disease outbreaks. This study aimed to evaluate the positivity rates and serotyping of Legionella species from water samples in the region of Antalya, Turkey, which is an important tourism center. During January-December 2010, a total of 1403 samples of water that were collected from various hotels (n = 56) located in Antalya were investigated for Legionella pneumophila. All samples were screened for L. pneumophila by culture method according to "ISO 11731-2" criteria. The culture positive Legionella strains were serologically identified by latex agglutination test. A total of 142 Legionella pneumophila isolates were recovered from 21 (37.5%) of 56 hotels. The total frequency of L. pneumophila isolation from water samples was found as 10.1%. Serological typing of 142 Legionella isolates by latex agglutination test revealed that strains belonging to L. pneumophila serogroups 2-14 predominated in the examined samples (85%), while strains of L. pneumophila serogroup 1 were less numerous (15%). According to our knowledge, our study with the greatest number of water samples from Turkey demonstrates that L. pneumophila serogroups 2-14 is the most common isolate. Rapid isolation of L. pneumophila from environmental water samples is essential for the investigation of travel related outbreaks and the possible resources. Further studies are needed to have epidemiological data and to determine the types of L

  1. [Evaluation of performance and false positivity of Mediace RPR test that uses a chemistry autoanalyzer].

    PubMed

    Noh, Jaekwang; Ko, Hak Hyun; Yun, Yeomin; Choi, Young Sook; Lee, Sang Gon; Shin, Sue; Han, Kyou Sup; Song, Eun Young

    2008-08-01

    We evaluated the performance and false positive rate of Mediace RPR test (Sekisui, Japan), a newly introduced nontreponemal test using a chemistry autoanalyzer. The sensitivity of Mediace RPR test was analyzed using sera from 50 patients with syphilis in different stages (8 primary, 7 secondary, and 35 latent), 14 sera positive with fluorescent treponemal antibody absorption (FTA-ABS) IgM, and 74 sera positive with conventional rapid plasma regain (RPR) card test (Asan, Korea) and also positive with Treponema pallidum hemagglutination (TPHA) test or FTA-ABS IgG test. The specificity was analyzed on 108 healthy blood donors. We also performed RPR card test on 302 sera that had been tested positive with Mediace RPR test and also performed TPHA or FTA-ABS IgG test to analyze the false positive rate of Mediace RPR test. A cutoff value of 0.5 R.U. (RPR unit) was used for Mediace RPR test. Mediace RPR test on syphilitic sera of different stages (primary, secondary, and latent stages) and FTA-ABS IgM positive sera showed a sensitivity of 100%, 100%, 82.9% and 100%, respectively. Among the 74 sera positive with conventional RPR card test and TPHA or FTA-ABS IgG test, 55 were positive with Mediace test. The specificity of Mediace RPR test on blood donors was 97.2%. Among the 302 sera positive with Mediace RPR test, 137 sera (45.4%) were negative by RPR card and TPHA/FTA-ABS IgG tests. Although the sensitivities of Mediace RPR were good for primary and secondary syphilis, due to its high negative rate of Mediace RPR over the conventional RPR positive samples, further studies are necessary whether it can replace conventional nontreponemal test for screening purpose. Moreover, in view of the high false positive rate, positive results by Mediace RPR test should be confirmed with treponemal tests.

  2. Swab or biopsy samples for bioburden testing of allograft musculoskeletal tissue?

    PubMed

    Varettas, Kerry

    2014-12-01

    Swab and biopsy samples of allograft musculoskeletal tissue are most commonly collected by tissue banks for bacterial and fungal bioburden testing. An in vitro study was performed using the National Committee for Clinical Laboratory Standards standard 'Quality control of microbiological transport systems' (2003) to validate and evaluate the recovery of six challenge organisms from swab and biopsy samples of allograft musculoskeletal tissue. On average, 8.4 to >100 and 7.2 to >100 % of the inoculum was recovered from swab and biopsy samples respectively. A retrospective review of donor episodes was also performed, consisting of paired swab and biopsy samples received in this laboratory during the period 2001-2012. Samples of allograft femoral heads were collected from living donors during hip operations. From the 3,859 donor episodes received, 21 paired swab and biopsy samples each recovered an isolate, 247 swab samples only and 79 biopsy samples only were culture positive. Low numbers of challenge organisms were recovered from inoculated swab and biopsy samples in the in vitro study and validated their use for bioburden testing of allograft musculoskeletal tissue. Skin commensals were the most common group of organisms isolated during a 12-year retrospective review of paired swab and biopsy samples from living donor allograft femoral heads. Paired swab and biopsy samples are a suitable representative sample of allograft musculoskeletal tissue for bioburden testing.

  3. Ultra-Gradient Test Cavity for Testing SRF Wafer Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    N.J. Pogue, P.M. McIntyre, A.I. Sattarov, C. Reece

    2010-11-01

    A 1.3 GHz test cavity has been designed to test wafer samples of superconducting materials. This mushroom shaped cavity, operating in TE01 mode, creates a unique distribution of surface fields. The surface magnetic field on the sample wafer is 3.75 times greater than elsewhere on the Niobium cavity surface. This field design is made possible through dielectrically loading the cavity by locating a hemisphere of ultra-pure sapphire just above the sample wafer. The sapphire pulls the fields away from the walls so the maximum field the Nb surface sees is 25% of the surface field on the sample. In thismore » manner, it should be possible to drive the sample wafer well beyond the BCS limit for Niobium while still maintaining a respectable Q. The sapphire's purity must be tested for its loss tangent and dielectric constant to finalize the design of the mushroom test cavity. A sapphire loaded CEBAF cavity has been constructed and tested. The results on the dielectric constant and loss tangent will be presented« less

  4. Experiences with an identification and quantification program for inhibitor-positive milk samples.

    PubMed

    Kress, Claudia; Seidler, Caroline; Kerp, Bianca; Schneider, Elisabeth; Usleber, Ewald

    2007-03-14

    Beta-lactam antibiotics (penicillins, cephalosporins) are still the most commonly used antibiotics for dairy cows in Germany. In routine milk testing, according to the German milk quality regulation, a positive result obtained for bulk tank milk by microbiological inhibitor tests needs no further confirmation, but results in reduced milk payment of 0.05 euros kg(-1) for one month. In some cases, however, further identification of the causative agent can be of interest, either if antimicrobial drugs have not knowingly been used recently, or if improper use of such drugs is denied. As a service for milk producers, our laboratory offers further analyses of violative milk samples, aiming at the identification and quantification of the inhibitor(s). In this program, a panel of microbiological inhibitor tests, receptor tests, and enzyme immunoassays (EIA) is used in a step-by-step analysis, which primarily focusses on beta-lactams, but also includes other compounds such as sulfonamides or tetracyclines, respectively. Here we report results for violative milk samples (n=63) analysed between 2003 and 2005. In most cases (95%), beta-lactam antibiotics could be identified, although not always at levels exceeding the respective MRL values. Penicillin G (mostly together with benzylpenicilloyl metabolites) could be identified in 74.6% of all samples. Other compounds identified were, in decreasing order, ceftiofur (11%), ampicillin/amoxicillin (6.3%), isoxazolyl penicillins (3.2%), and sulfonamides (1.6%). The results indicate that penicillin G is still the predominant antibiotic responsible for violative bulk tank milk samples as detected during regulatory control.

  5. Daily self-sampling for high-risk human papillomavirus (HR-HPV) testing.

    PubMed

    Sanner, Karin; Wikström, Ingrid; Gustavsson, Inger; Wilander, Erik; Lindberg, Julia Hedlund; Gyllensten, Ulf; Olovsson, Matts

    2015-12-01

    Self-sampling for HPV as part of primary screening is a well-tolerated method for women not attending organized Pap smear screening and could increase coverage of cervical cancer screening. To investigate if the prevalence of HR-HPV varies from day to day in infected women and if one single sample is reliable for detecting an ongoing infection. This is a prospective cohort study on 12 premenopausal and 13 postmenopausal women performing daily self-sampling for HR-HPV testing. They were all HR-HPV-positive 1-3 months ago. Postmenopausal women were sampled for 28 days and premenopausal women sampled during bleeding-free days in one menstrual cycle. A possible difference in viral load between the estrogen-dominated proliferative phase and the progesterone-dominated secretory phase was analyzed. Consistent results throughout the sampling period were observed for 19 women, with either a daily presence of HPV (14 women) or no HPV at all during the sampling period (5 women). Of 607 samples from 25 women, 596 were consistently positive or negative for HPV during the sampling period and 11 were inconsistent (2%). There was no difference in HPV copy number between the estrogen dominated proliferative or progesterone dominated secretory menstrual cycle phases. The major finding was a high degree of consistency concerning HR-HPV positivity and negativity of HR-HPV in vaginal fluid during a sustained period of daily self-sampling. It does not appear to matter whether the sample is collected in the proliferative or secretory phase. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Salmonella testing of pooled pre-enrichment broth cultures for screening multiple food samples.

    PubMed

    Price, W R; Olsen, R A; Hunter, J E

    1972-04-01

    A method has been described for testing multiple food samples for Salmonella without loss in sensitivity. The method pools multiple pre-enrichment broth cultures into single enrichment broths. The subsequent stages of the Salmonella analysis are not altered. The method was found applicable to several dry food materials including nonfat dry milk, dried egg albumin, cocoa, cottonseed flour, wheat flour, and shredded coconut. As many as 25 pre-enrichment broth cultures were pooled without apparent loss in the sensitivity of Salmonella detection as compared to individual sample analysis. The procedure offers a simple, yet effective, way to increase sample capacity in the Salmonella testing of foods, particularly where a large proportion of samples ordinarily is negative. It also permits small portions of pre-enrichment broth cultures to be retained for subsequent individual analysis if positive tests are found. Salmonella testing of pooled pre-enrichment broths provides increased consumer protection for a given amount of analytical effort as compared to individual sample analysis.

  7. Reveal Listeria 2.0 test for detection of Listeria spp. in foods and environmental samples.

    PubMed

    Alles, Susan; Curry, Stephanie; Almy, David; Jagadeesan, Balamurugan; Rice, Jennifer; Mozola, Mark

    2012-01-01

    A Performance Tested Method validation study was conducted for a new lateral flow immunoassay (Reveal Listeria 2.0) for detection of Listeria spp. in foods and environmental samples. Results of inclusivity testing showed that the test detects all species of Listeria, with the exception of L. grayi. In exclusivity testing conducted under nonselective growth conditions, all non-listeriae tested produced negative Reveal assay results, except for three strains of Lactobacillus spp. However, these lactobacilli are inhibited by the selective Listeria Enrichment Single Step broth enrichment medium used with the Reveal method. Six foods were tested in parallel by the Reveal method and the U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) reference culture procedure. Considering data from both internal and independent laboratory trials, overall sensitivity of the Reveal method relative to that of the FDA/BAM procedure was 101%. Four foods were tested in parallel by the Reveal method and the U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) reference culture procedure. Overall sensitivity of the Reveal method relative to that of the USDA-FSIS procedure was 98.2%. There were no statistically significant differences in the number of positives obtained by the Reveal and reference culture procedures in any food trials. In testing of swab or sponge samples from four types of environmental surfaces, sensitivity of Reveal relative to that of the USDA-FSIS reference culture procedure was 127%. For two surface types, differences in the number of positives obtained by the Reveal and reference methods were statistically significant, with more positives by the Reveal method in both cases. Specificity of the Reveal assay was 100%, as there were no unconfirmed positive results obtained in any phase of the testing. Results of ruggedness experiments showed that the Reveal assay is tolerant of modest deviations in test sample volume and

  8. Evaluation of fecal elastase and serum cholecystokinin in dogs with a false positive fecal elastase test.

    PubMed

    Steiner, J M; Rehfeld, J F; Pantchev, N

    2010-01-01

    An assay for the measurement of pancreatic elastase in dog feces has been introduced. The goal of this study was to evaluate the rate of false-positive fecal-elastase test results in dogs with suspected exocrine pancreatic insufficiency (EPI) and to assess serum cholecystokinin (CCK) concentrations in dogs with a false positive fecal elastase test result. Twenty-six fecal and serum samples from dogs suspected of EPI, for which samples had been submitted to a commercial laboratory (Vet Med Labor) for analysis. Prospective study. Serum trypsin-like immunoreactivity (TLI) was measured in 26 dogs with a decreased fecal elastase concentration of <10 microg/g feces. Serum CCK concentrations were measured in 21 of these dogs. Of 26 dogs with a decreased fecal elastase concentration, 6 (23%) had serum TLI concentrations within or above the reference range. Serum CCK concentrations were significantly higher in dogs with a true positive fecal elastase test result (median: 1.1 pmol/L; range: 0.1-3.3 pmol/L) than in those with a false positive fecal elastase test result (median: 0.1 pmol/L; range: 0.1-0.9 pmol/L; P value = .0163). The rate of false positive fecal elastase test results was high in this group of dogs, suggesting that diagnosis of EPI must be confirmed by other means. The decreased CCK concentration in dogs with a false positive fecal elastase test result could suggest that false positive results are because of decreased stimulation of exocrine pancreatic function caused by other conditions.

  9. Screening for gonorrhoea using samples collected through the English national chlamydia screening programme and risk of false positives: a national survey of local authorities.

    PubMed

    Field, Nigel; Kennedy, Iain; Folkard, Kate; Duffell, Stephen; Town, Katy; Ison, Catherine A; Hughes, Gwenda

    2014-10-16

    To investigate use of dual tests for Chlamydia trachomatis and Neisseria gonorrhoeae on samples collected through the National Chlamydia Screening Programme (NCSP) in England. During May-July 2013, we delivered an online survey to commissioners of sexual health services in the 152 upper-tier English Local Authorities (LAs) who were responsible for commissioning chlamydia screening in people aged 15-24 years. (1) The proportion of English LAs using dual tests on samples collected by the NCSP; (2) The estimated number of gonorrhoea tests and false positives from samples collected by the NCSP, calculated using national surveillance data on the number of chlamydia tests performed, assuming the gonorrhoea prevalence to range between 0.1% and 1%, and test sensitivity and specificity of 99.5%. 64% (98/152) of LAs responded to this national survey; over half (53% (52/98)) reported currently using dual tests in community settings. There was no significant difference between LAs using and not using dual tests by chlamydia positivity, chlamydia diagnosis rate or population screening coverage. Although positive gonorrhoea results were confirmed with supplementary tests in 93% (38/41) of LAs, this occurred after patients were notified about the initial positive result in 63% (26/41). Approximately 450-4500 confirmed gonorrhoea diagnoses and 2300 false-positive screens might occur through use of dual tests on NCSP samples each year. Under reasonable assumptions, the positive predictive value of the screening test is 17-67%. Over half of English LAs already commission dual tests for samples collected by the NCSP. Gonorrhoea screening has been introduced alongside chlamydia screening in many low prevalence settings without a national evidence review or change of policy. We question the public health benefit here, and suggest that robust testing algorithms and clinical management pathways, together with rigorous evaluation, be implemented wherever dual tests are deployed

  10. Screening for gonorrhoea using samples collected through the English National Chlamydia Screening Programme and risk of false positives: a national survey of Local Authorities

    PubMed Central

    Field, Nigel; Kennedy, Iain; Folkard, Kate; Duffell, Stephen; Town, Katy; Ison, Catherine A; Hughes, Gwenda

    2014-01-01

    Objectives To investigate use of dual tests for Chlamydia trachomatis and Neisseria gonorrhoeae on samples collected through the National Chlamydia Screening Programme (NCSP) in England. Design and setting During May–July 2013, we delivered an online survey to commissioners of sexual health services in the 152 upper-tier English Local Authorities (LAs) who were responsible for commissioning chlamydia screening in people aged 15–24 years. Main outcome measures (1) The proportion of English LAs using dual tests on samples collected by the NCSP; (2) The estimated number of gonorrhoea tests and false positives from samples collected by the NCSP, calculated using national surveillance data on the number of chlamydia tests performed, assuming the gonorrhoea prevalence to range between 0.1% and 1%, and test sensitivity and specificity of 99.5%. Results 64% (98/152) of LAs responded to this national survey; over half (53% (52/98)) reported currently using dual tests in community settings. There was no significant difference between LAs using and not using dual tests by chlamydia positivity, chlamydia diagnosis rate or population screening coverage. Although positive gonorrhoea results were confirmed with supplementary tests in 93% (38/41) of LAs, this occurred after patients were notified about the initial positive result in 63% (26/41). Approximately 450–4500 confirmed gonorrhoea diagnoses and 2300 false-positive screens might occur through use of dual tests on NCSP samples each year. Under reasonable assumptions, the positive predictive value of the screening test is 17–67%. Conclusions Over half of English LAs already commission dual tests for samples collected by the NCSP. Gonorrhoea screening has been introduced alongside chlamydia screening in many low prevalence settings without a national evidence review or change of policy. We question the public health benefit here, and suggest that robust testing algorithms and clinical management pathways, together

  11. 'Nano-immuno test' for the detection of live Mycobacterium avium subspecies paratuberculosis bacilli in the milk samples using magnetic nano-particles and chromogen.

    PubMed

    Singh, Manju; Singh, Shoor Vir; Gupta, Saurabh; Chaubey, Kundan Kumar; Stephan, Bjorn John; Sohal, Jagdip Singh; Dutta, Manali

    2018-04-26

    Early rapid detection of Mycobacterium avium subspecies paratuberculosis (MAP) bacilli in milk samples is the major challenge since traditional culture method is time consuming and laboratory dependent. We report a simple, sensitive and specific nano-technology based 'Nano-immuno test' capable of detecting viable MAP bacilli in the milk samples within 10 h. Viable MAP bacilli were captured by MAP specific antibody-conjugated magnetic nano-particles using resazurin dye as chromogen. Test was optimized using true culture positive (10-bovine and 12-goats) and true culture negative (16-bovine and 25-goats) raw milk samples. Domestic livestock species in India are endemically infected with MAP. After successful optimization, sensitivity and specificity of the 'nano-immuno test' in goats with respect to milk culture was 91.7% and 96.0%, respectively. Whereas, it was 90.0% (sensitivity) and 92.6% (specificity) with respect to IS900 PCR. In bovine milk samples, sensitivity and specificity of 'nano-immuno test' with respect to milk culture was 90.0% and 93.7%, respectively. However, with respect to IS900 PCR, the sensitivity and specificity was 88.9% and 94.1%, respectively. Test was validated with field raw milk samples (goats-258 and bovine-138) collected from domestic livestock species to detect live/viable MAP bacilli. Of 138 bovine raw milk samples screened by six diagnostic tests, 81 (58.7%) milk samples were positive for MAP infection in one or more than one diagnostic tests. Of 81 (58.7%) positive bovine raw milk samples, only 24 (17.4%) samples were detected positive for the presence of viable MAP bacilli. Of 258 goats raw milk samples screened by six diagnostic tests, 141 (54.6%) were positive for MAP infection in one or more than one test. Of 141 (54.6%) positive raw milk samples from goats, only 48 (34.0%) were detected positive for live MAP bacilli. Simplicity and efficiency of this novel 'nano-immuno test' makes it suitable for wide-scale screening of milk

  12. Evaluation of the hyplex® TBC PCR test for detection of Mycobacterium tuberculosis complex in clinical samples

    PubMed Central

    2010-01-01

    Background Tuberculosis (TB) is one of the major public health concerns worldwide. The detection of the pathogen Mycobacterium tuberculosis complex (MTBC) as early as possible has a great impact on the effective control of the spread of the disease. In our study, we evaluated the hyplex® TBC PCR test (BAG Health Care GmbH), a novel assay using a nucleic acid amplification technique (NAAT) with reverse hybridisation and ELISA read out for the rapid detection of M. tuberculosis directly in clinical samples. Results A total of 581 respiratory and non-respiratory specimens from our pneumological hospital and the National TB Institute of Uzbekistan were used for the evaluation of the PCR assay. Of these, 292 were classified as TB samples and 289 as non-TB samples based on the results of the TB cultures as reference method. The PCR results were initially used to optimise the cut-off value of the hyplex® TBC test system by means of a ROC analysis. The overall sensitivity of the assay was determined to be 83.1%. In smear-positive TB samples, the sensitivity of the hyplex® TBC PCR test was estimated to 93.4% versus 45.1% in smear-negative samples. The specificity of the test was 99.25%. Of the two specimens (0.75%) with false-positive PCR results, one yielded a culture positive for non-tuberculous mycobacteria. Based on the assumption of a prevalence of 8% TB positives among the samples in our diagnostic TB laboratory, the positive and negative predictive values were estimated to 90.4% and 98.5%, respectively. Conclusions The hyplex® TBC PCR test is an accurate NAAT assay for a rapid and reliable detection of M. tuberculosis in various respiratory and non-respiratory specimens. Compared to many other conventional NAAT assays, the hyplex® TBC PCR test is in a low price segment which makes it an attractive option for developing and emerging countries with high TB burdens. PMID:20356361

  13. Easy fix for clinical laboratories for the false-positive defect with the Abbott AxSym total beta-hCG test.

    PubMed

    Cole, Laurence A; Khanlian, Sarah A

    2004-05-01

    False-positive hCG results can lead to erroneous diagnoses and needless chemotherapy and surgery. In the last 2 years, eight publications described cases involving false-positive hCG tests; all eight involved the AxSym test. We investigated the source of this abundance of cases and a simple fix that may be used by clinical laboratories. False-positive hCG was primarily identified by absence of hCG in urine and varying or negative hCG results in alternative tests. Seventeen false-positive serum samples in the AxSym test were evaluated undiluted and at twofold dilution with diluent containing excess goat serum or immunoglobulin. We identified 58 patients with false-positive hCG, 47 of 58 due to the Abbott AxSym total hCGbeta test (81%). Sixteen of 17 of these "false-positive" results (mean 100 mIU/ml) became undetectable when tested again after twofold dilution. A simple twofold dilution with this diluent containing excess goat serum or immunoglobulin completely protected 16 of 17 samples from patients having false-positive results. It is recommended that laboratories using this test use twofold dilution as a minimum to prevent false-positive results.

  14. 30 CFR 14.5 - Test samples.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Test samples. 14.5 Section 14.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... Test samples. Upon request by MSHA, the applicant must submit 3 precut, unrolled, flat conveyor belt...

  15. 30 CFR 14.5 - Test samples.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Test samples. 14.5 Section 14.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... Test samples. Upon request by MSHA, the applicant must submit 3 precut, unrolled, flat conveyor belt...

  16. 30 CFR 14.5 - Test samples.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Test samples. 14.5 Section 14.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... Test samples. Upon request by MSHA, the applicant must submit 3 precut, unrolled, flat conveyor belt...

  17. HIV testing behaviors of a cohort of HIV-positive racial/ethnic minority YMSM.

    PubMed

    Phillips, Gregory; Hightow-Weidman, Lisa B; Arya, Monisha; Fields, Sheldon D; Halpern-Felsher, Bonnie; Outlaw, Angulique Y; Wohl, Amy R; Hidalgo, Julia

    2012-10-01

    The HIV epidemic in the United States has disproportionately affected young racial/ethnic minority men who have sex with men (YMSM). However, HIV testing rates among young men of color remain low. Within this sample of racial/ethnic minority YMSM (n = 363), the first HIV test was a median of 2 years after men who have sex with men sexual debut. Individuals with less than 1 year between their first negative and first positive HIV test were significantly more likely to identify the reason for their first negative test as being sick (OR = 2.99; 95 % CI 1.23-7.27). This may suggest that these YMSM may have experienced symptoms of acute HIV infection. Of major concern is that many YMSM in our study tested positive for HIV on their first HIV test. Given recommendations for at least annual HIV testing, our findings reveal that medical providers YMSM need to know the importance of regular testing.

  18. Cost-effectiveness of one versus two sample faecal immunochemical testing for colorectal cancer screening.

    PubMed

    Goede, S Lucas; van Roon, Aafke H C; Reijerink, Jacqueline C I Y; van Vuuren, Anneke J; Lansdorp-Vogelaar, Iris; Habbema, J Dik F; Kuipers, Ernst J; van Leerdam, Monique E; van Ballegooijen, Marjolein

    2013-05-01

    The sensitivity and specificity of a single faecal immunochemical test (FIT) are limited. The performance of FIT screening can be improved by increasing the screening frequency or by providing more than one sample in each screening round. This study aimed to evaluate if two-sample FIT screening is cost-effective compared with one-sample FIT. The MISCAN-colon microsimulation model was used to estimate costs and benefits of strategies with either one or two-sample FIT screening. The FIT cut-off level varied between 50 and 200 ng haemoglobin/ml, and the screening schedule was varied with respect to age range and interval. In addition, different definitions for positivity of the two-sample FIT were considered: at least one positive sample, two positive samples, or the mean of both samples being positive. Within an exemplary screening strategy, biennial FIT from the age of 55-75 years, one-sample FIT provided 76.0-97.0 life-years gained (LYG) per 1000 individuals, at a cost of € 259,000-264,000 (range reflects different FIT cut-off levels). Two-sample FIT screening with at least one sample being positive provided 7.3-12.4 additional LYG compared with one-sample FIT at an extra cost of € 50,000-59,000. However, when all screening intervals and age ranges were considered, intensifying screening with one-sample FIT provided equal or more LYG at lower costs compared with two-sample FIT. If attendance to screening does not differ between strategies it is recommended to increase the number of screening rounds with one-sample FIT screening, before considering increasing the number of FIT samples provided per screening round.

  19. Dynamic X-ray diffraction sampling for protein crystal positioning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scarborough, Nicole M.; Godaliyadda, G. M. Dilshan P.; Ye, Dong Hye

    A sparse supervised learning approach for dynamic sampling (SLADS) is described for dose reduction in diffraction-based protein crystal positioning. Crystal centering is typically a prerequisite for macromolecular diffraction at synchrotron facilities, with X-ray diffraction mapping growing in popularity as a mechanism for localization. In X-ray raster scanning, diffraction is used to identify the crystal positions based on the detection of Bragg-like peaks in the scattering patterns; however, this additional X-ray exposure may result in detectable damage to the crystal prior to data collection. Dynamic sampling, in which preceding measurements inform the next most information-rich location to probe for image reconstruction,more » significantly reduced the X-ray dose experienced by protein crystals during positioning by diffraction raster scanning. The SLADS algorithm implemented herein is designed for single-pixel measurements and can select a new location to measure. In each step of SLADS, the algorithm selects the pixel, which, when measured, maximizes the expected reduction in distortion given previous measurements. Ground-truth diffraction data were obtained for a 5 µm-diameter beam and SLADS reconstructed the image sampling 31% of the total volume and only 9% of the interior of the crystal greatly reducing the X-ray dosage on the crystal. Furthermore, by usingin situtwo-photon-excited fluorescence microscopy measurements as a surrogate for diffraction imaging with a 1 µm-diameter beam, the SLADS algorithm enabled image reconstruction from a 7% sampling of the total volume and 12% sampling of the interior of the crystal. When implemented into the beamline at Argonne National Laboratory, without ground-truth images, an acceptable reconstruction was obtained with 3% of the image sampled and approximately 5% of the crystal. The incorporation of SLADS into X-ray diffraction acquisitions has the potential to significantly minimize the impact of X-ray exposure

  20. Dynamic X-ray diffraction sampling for protein crystal positioning

    PubMed Central

    Scarborough, Nicole M.; Godaliyadda, G. M. Dilshan P.; Ye, Dong Hye; Kissick, David J.; Zhang, Shijie; Newman, Justin A.; Sheedlo, Michael J.; Chowdhury, Azhad U.; Fischetti, Robert F.; Das, Chittaranjan; Buzzard, Gregery T.; Bouman, Charles A.; Simpson, Garth J.

    2017-01-01

    A sparse supervised learning approach for dynamic sampling (SLADS) is described for dose reduction in diffraction-based protein crystal positioning. Crystal centering is typically a prerequisite for macromolecular diffraction at synchrotron facilities, with X-ray diffraction mapping growing in popularity as a mechanism for localization. In X-ray raster scanning, diffraction is used to identify the crystal positions based on the detection of Bragg-like peaks in the scattering patterns; however, this additional X-ray exposure may result in detectable damage to the crystal prior to data collection. Dynamic sampling, in which preceding measurements inform the next most information-rich location to probe for image reconstruction, significantly reduced the X-ray dose experienced by protein crystals during positioning by diffraction raster scanning. The SLADS algorithm implemented herein is designed for single-pixel measurements and can select a new location to measure. In each step of SLADS, the algorithm selects the pixel, which, when measured, maximizes the expected reduction in distortion given previous measurements. Ground-truth diffraction data were obtained for a 5 µm-diameter beam and SLADS reconstructed the image sampling 31% of the total volume and only 9% of the interior of the crystal greatly reducing the X-ray dosage on the crystal. Using in situ two-photon-excited fluorescence microscopy measurements as a surrogate for diffraction imaging with a 1 µm-diameter beam, the SLADS algorithm enabled image reconstruction from a 7% sampling of the total volume and 12% sampling of the interior of the crystal. When implemented into the beamline at Argonne National Laboratory, without ground-truth images, an acceptable reconstruction was obtained with 3% of the image sampled and approximately 5% of the crystal. The incorporation of SLADS into X-ray diffraction acquisitions has the potential to significantly minimize the impact of X-ray exposure on the crystal by

  1. Dynamic X-ray diffraction sampling for protein crystal positioning.

    PubMed

    Scarborough, Nicole M; Godaliyadda, G M Dilshan P; Ye, Dong Hye; Kissick, David J; Zhang, Shijie; Newman, Justin A; Sheedlo, Michael J; Chowdhury, Azhad U; Fischetti, Robert F; Das, Chittaranjan; Buzzard, Gregery T; Bouman, Charles A; Simpson, Garth J

    2017-01-01

    A sparse supervised learning approach for dynamic sampling (SLADS) is described for dose reduction in diffraction-based protein crystal positioning. Crystal centering is typically a prerequisite for macromolecular diffraction at synchrotron facilities, with X-ray diffraction mapping growing in popularity as a mechanism for localization. In X-ray raster scanning, diffraction is used to identify the crystal positions based on the detection of Bragg-like peaks in the scattering patterns; however, this additional X-ray exposure may result in detectable damage to the crystal prior to data collection. Dynamic sampling, in which preceding measurements inform the next most information-rich location to probe for image reconstruction, significantly reduced the X-ray dose experienced by protein crystals during positioning by diffraction raster scanning. The SLADS algorithm implemented herein is designed for single-pixel measurements and can select a new location to measure. In each step of SLADS, the algorithm selects the pixel, which, when measured, maximizes the expected reduction in distortion given previous measurements. Ground-truth diffraction data were obtained for a 5 µm-diameter beam and SLADS reconstructed the image sampling 31% of the total volume and only 9% of the interior of the crystal greatly reducing the X-ray dosage on the crystal. Using in situ two-photon-excited fluorescence microscopy measurements as a surrogate for diffraction imaging with a 1 µm-diameter beam, the SLADS algorithm enabled image reconstruction from a 7% sampling of the total volume and 12% sampling of the interior of the crystal. When implemented into the beamline at Argonne National Laboratory, without ground-truth images, an acceptable reconstruction was obtained with 3% of the image sampled and approximately 5% of the crystal. The incorporation of SLADS into X-ray diffraction acquisitions has the potential to significantly minimize the impact of X-ray exposure on the crystal by

  2. Dynamic X-ray diffraction sampling for protein crystal positioning

    DOE PAGES

    Scarborough, Nicole M.; Godaliyadda, G. M. Dilshan P.; Ye, Dong Hye; ...

    2017-01-01

    A sparse supervised learning approach for dynamic sampling (SLADS) is described for dose reduction in diffraction-based protein crystal positioning. Crystal centering is typically a prerequisite for macromolecular diffraction at synchrotron facilities, with X-ray diffraction mapping growing in popularity as a mechanism for localization. In X-ray raster scanning, diffraction is used to identify the crystal positions based on the detection of Bragg-like peaks in the scattering patterns; however, this additional X-ray exposure may result in detectable damage to the crystal prior to data collection. Dynamic sampling, in which preceding measurements inform the next most information-rich location to probe for image reconstruction,more » significantly reduced the X-ray dose experienced by protein crystals during positioning by diffraction raster scanning. The SLADS algorithm implemented herein is designed for single-pixel measurements and can select a new location to measure. In each step of SLADS, the algorithm selects the pixel, which, when measured, maximizes the expected reduction in distortion given previous measurements. Ground-truth diffraction data were obtained for a 5 µm-diameter beam and SLADS reconstructed the image sampling 31% of the total volume and only 9% of the interior of the crystal greatly reducing the X-ray dosage on the crystal. Furthermore, by usingin situtwo-photon-excited fluorescence microscopy measurements as a surrogate for diffraction imaging with a 1 µm-diameter beam, the SLADS algorithm enabled image reconstruction from a 7% sampling of the total volume and 12% sampling of the interior of the crystal. When implemented into the beamline at Argonne National Laboratory, without ground-truth images, an acceptable reconstruction was obtained with 3% of the image sampled and approximately 5% of the crystal. The incorporation of SLADS into X-ray diffraction acquisitions has the potential to significantly minimize the impact of X-ray exposure

  3. Positive tuberculin skin tests in nursing home residents in Southern Taiwan.

    PubMed

    Chang, Chia-Ming; Lee, Nan-Yao; Lee, Hsin-Chun; Wu, Chi-Jung; Chen, Po-Lin; Lee, Ching-Chi; Shih, Hsin-I; Ko, Wen-Chien

    2010-01-01

    In Taiwan, the tuberculin skin test (TST) is not recommended as a screening test for Mycobacterium tuberculosis (TB) infections. The aim of this study is to determine the prevalence and predictors of positive tuberculin reactivity and its association with TB infections among nursing home residents in Taiwan. A cross-sectional study and review of medical records were conducted at four nursing homes in Tainan City. A one-stage TST was performed by study nurses using two tuberculin units of purified protein derivative (PPD) of the RT23 strain. An induration ≥10 mm at 72 h was considered to be a positive reaction. Chest radiographs, acid-fast stains and mycobacterial cultures of three sputum samples were performed for those with a positive TST result. Of 115 residents (66.5% participation, mean age 73.1 years) who underwent a TST, 26 (22.6%) had a positive reaction. One woman was microbiologically diagnosed to have pulmonary TB. On multivariate analysis, a Bacille Calmette-Guérin (BCG) scar and a history of myocardial infarction were significantly associated with a positive TST. In conclusions, this study shows a considerable rate of positive TST among nursing home residents in southern Taiwan. A BCG scar and a history of myocardial infarction were associated with a positive TST. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  4. Sample Holder for Cryogenic Adhesive Shear Test

    NASA Technical Reports Server (NTRS)

    Ledbetter, F. E.; Clemons, J. M.; White, W. T.; Penn, B.; Semmel, M. L.

    1983-01-01

    Five samples tested in one cooldown. Holder mounted in testing machine. Submerged in cryogenic liquid held in cryostat. Movable crosshead of testing machine moves gradually downward. Samples placed under tension, one after another, starting with top one; each sample fails in turn before next is stressed.

  5. Synthesizing Information From Language Samples and Standardized Tests in School-Age Bilingual Assessment

    PubMed Central

    Pham, Giang

    2017-01-01

    Purpose Although language samples and standardized tests are regularly used in assessment, few studies provide clinical guidance on how to synthesize information from these testing tools. This study extends previous work on the relations between tests and language samples to a new population—school-age bilingual speakers with primary language impairment—and considers the clinical implications for bilingual assessment. Method Fifty-one bilingual children with primary language impairment completed narrative language samples and standardized language tests in English and Spanish. Children were separated into younger (ages 5;6 [years;months]–8;11) and older (ages 9;0–11;2) groups. Analysis included correlations with age and partial correlations between language sample measures and test scores in each language. Results Within the younger group, positive correlations with large effect sizes indicated convergence between test scores and microstructural language sample measures in both Spanish and English. There were minimal correlations in the older group for either language. Age related to English but not Spanish measures. Conclusions Tests and language samples complement each other in assessment. Wordless picture-book narratives may be more appropriate for ages 5–8 than for older children. We discuss clinical implications, including a case example of a bilingual child with primary language impairment, to illustrate how to synthesize information from these tools in assessment. PMID:28055056

  6. Stability of (13) C-Urea Breath Test Samples Over Time in the Diagnosis of Helicobacter pylori.

    PubMed

    Perets, Tsachi Tsadok; Shporn, Einav; Boltin, Doron; Dickman, Ram; Niv, Yaron

    2016-05-01

    The accuracy and repeatability of breath test in the diagnosis of Helicobacter pylori infection have not been adequately investigated. Although it has been shown that storage for long periods does not affect the analysis results, no data are available on the effect of repetitive testing. In this study, our aim was to evaluate the repeatability of the analyses of breath samples at room temperature. A total of 202 positive breath samples were collected in duplicates, before and after administration of 75 mg (13) C- urea dissolved in 100 ml of orange juice. Breath test results were expressed as delta (13) CO2 . The cut-off value was 3.5 parts per thousand. Each sample was analyzed in a mass spectrometer 7, 14, 21, and 28 days after collection. The accuracy calculation was based on the comparison of the delta (13) CO2 obtained in the three consecutive weeks following the first test run to the delta (13) CO2 obtained in the first test run. Two hundred (99%), 197 (97.52%), and 196 (97%) of the 202 samples tested positive in the second, third, and fourth test runs, respectively. The accuracy of the delta (13) CO2 was 98.6%, 99.2%, and 96.7% in the three consecutive runs, respectively. Short-term storage of 1 month does not affect sample stability or the results of (13) C-urea breath tests in up to three consecutive repeats. © 2015 Wiley Periodicals, Inc.

  7. Sample size for positive and negative predictive value in diagnostic research using case–control designs

    PubMed Central

    Steinberg, David M.; Fine, Jason; Chappell, Rick

    2009-01-01

    Important properties of diagnostic methods are their sensitivity, specificity, and positive and negative predictive values (PPV and NPV). These methods are typically assessed via case–control samples, which include one cohort of cases known to have the disease and a second control cohort of disease-free subjects. Such studies give direct estimates of sensitivity and specificity but only indirect estimates of PPV and NPV, which also depend on the disease prevalence in the tested population. The motivating example arises in assay testing, where usage is contemplated in populations with known prevalences. Further instances include biomarker development, where subjects are selected from a population with known prevalence and assessment of PPV and NPV is crucial, and the assessment of diagnostic imaging procedures for rare diseases, where case–control studies may be the only feasible designs. We develop formulas for optimal allocation of the sample between the case and control cohorts and for computing sample size when the goal of the study is to prove that the test procedure exceeds pre-stated bounds for PPV and/or NPV. Surprisingly, the optimal sampling schemes for many purposes are highly unbalanced, even when information is desired on both PPV and NPV. PMID:18556677

  8. Assessing the potential for racial bias in hair analysis for cocaine: examining the relative risk of positive outcomes when comparing urine samples to hair samples.

    PubMed

    Mieczkowski, Tom

    2011-03-20

    This article examines the conjecture that hair analysis, performed to detect cocaine use or exposure, is biased against African Americans. It does so by comparing the outcomes of 33,928 hair and 105,792 urine samples collected from both African American and white subjects. In making this comparison the analysis seeks to determine if there is a departure in rates of positive and negative outcomes when comparing the results of hair analysis for cocaine to the results from urinalysis for cocaine by racial group. It treats urine as an unbiased test. It compares both the relative ratios of positive outcomes when comparing the two groups and it calculates the relative risk of outcomes for each group for having positive or negative outcomes. The findings show that the ratios of each racial group are effectively same for hair and urine assays, and they also show that the relative risk and risk estimates for positive and negative outcomes are the same for both racial groups. Considering all samples, the cocaine positive risk estimate for the hair samples comparing the two racial groups is 3.28 and for urinalysis the risk estimate is 3.10 (Breslow-Day χ(2) .250, 1 df, p = 0.617) a non-significant difference in risk. For pre-employment samples, the cocaine positive risk estimate for the hair samples comparing the two racial groups is 3.10 and for urinalysis the risk estimate is 2.90 (Breslow-Day χ(2) .281, df = 1, p = 0.595), also a non-significant difference in risk. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  9. ISOLOK VALVE ACCEPTANCE TESTING FOR DWPF SME SAMPLING PROCESS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, T.; Hera, K.; Coleman, C.

    2011-12-05

    locations were compared to determine if the contents of the tank were well mixed. The Coliwasa sampler is a tube with a stopper at the bottom and is designed to obtain grab samples from specific locations within the drum contents. A position paper (4) was issued to address the prototypic flow loop issues and simulant selections. A statistically designed plan (5) was issued to address the total number of samples each sampler needed to pull, to provide the random order in which samples were pulled and to group samples for elemental analysis. The TTR required that the Isolok sampler perform as well as the Hydragard sampler during these tests to ensure the acceptability of the Isolok sampler for use in the DWPF sampling cells. Procedure No.L9.4-5015 was used to document the sample parameters and process steps. Completed procedures are located in R&D Engineering job folder 23269.« less

  10. Student drug testing and positive school climates: testing the relation between two school characteristics and drug use behavior in a longitudinal study.

    PubMed

    Sznitman, Sharon R; Romer, Daniel

    2014-01-01

    Fostering positive school climates and student drug testing have been separately proposed as strategies to reduce student drug use in high schools. To assess the promise of these strategies, the present research examined whether positive school climates and/or student drug testing successfully predicted changes in youth substance use over a 1-year follow-up. Two waves of panel data from a sample of 361 high school students, assessed 1 year apart, were analyzed. Changes in reported initiation and escalation in frequency of alcohol, cigarette, and marijuana use as a function of perceived student drug testing and positive school climates were analyzed, while we held constant prior substance use. Perceived student drug testing was not associated with changes in substance use, whereas perceived positive school climates were associated with a reduction in cigarette and marijuana initiation and a reduction in escalation of frequency of cigarette use at 1-year follow-up. However, perceived positive school climates were not associated with a reduction in alcohol use. Student drug testing appears to be less associated with substance use than positive school climates. Nevertheless, even favorable school climates may not be able to influence the use of alcohol, which appears to be quite normative in this age group.

  11. Sample Size Determination for One- and Two-Sample Trimmed Mean Tests

    ERIC Educational Resources Information Center

    Luh, Wei-Ming; Olejnik, Stephen; Guo, Jiin-Huarng

    2008-01-01

    Formulas to determine the necessary sample sizes for parametric tests of group comparisons are available from several sources and appropriate when population distributions are normal. However, in the context of nonnormal population distributions, researchers recommend Yuen's trimmed mean test, but formulas to determine sample sizes have not been…

  12. Self-Sampling for Human Papillomavirus Testing: Increased Cervical Cancer Screening Participation and Incorporation in International Screening Programs

    PubMed Central

    Gupta, Sarah; Palmer, Christina; Bik, Elisabeth M.; Cardenas, Juan P.; Nuñez, Harold; Kraal, Laurens; Bird, Sara W.; Bowers, Jennie; Smith, Alison; Walton, Nathaniel A.; Goddard, Audrey D.; Almonacid, Daniel E.; Zneimer, Susan; Richman, Jessica; Apte, Zachary S.

    2018-01-01

    In most industrialized countries, screening programs for cervical cancer have shifted from cytology (Pap smear or ThinPrep) alone on clinician-obtained samples to the addition of screening for human papillomavirus (HPV), its main causative agent. For HPV testing, self-sampling instead of clinician-sampling has proven to be equally accurate, in particular for assays that use nucleic acid amplification techniques. In addition, HPV testing of self-collected samples in combination with a follow-up Pap smear in case of a positive result is more effective in detecting precancerous lesions than a Pap smear alone. Self-sampling for HPV testing has already been adopted by some countries, while others have started trials to evaluate its incorporation into national cervical cancer screening programs. Self-sampling may result in more individuals willing to participate in cervical cancer screening, because it removes many of the barriers that prevent women, especially those in low socioeconomic and minority populations, from participating in regular screening programs. Several studies have shown that the majority of women who have been underscreened but who tested HPV-positive in a self-obtained sample will visit a clinic for follow-up diagnosis and management. In addition, a self-collected sample can also be used for vaginal microbiome analysis, which can provide additional information about HPV infection persistence as well as vaginal health in general. PMID:29686981

  13. Assessing Positivity and Circulating Levels of NS1 in Samples from a 2012 Dengue Outbreak in Rio de Janeiro, Brazil

    PubMed Central

    Allonso, Diego; Meneses, Marcelo D. F.; Fernandes, Carlos A.; Ferreira, Davis F.; Mohana-Borges, Ronaldo

    2014-01-01

    Dengue virus (DENV) represents a major threat to public health worldwide. Early DENV diagnosis should not only detect the infection but also identify patients with a higher likelihood to develop severe cases. Previous studies have suggested the potential for NS1 to serve as a viral marker for dengue severity. However, further studies using different sera panels are required to confirm this hypothesis. In this context, we developed a lab-based ELISA to detect and quantitate NS1 protein from the four DENV serotypes and from primary and secondary cases. This approach was used to calculate the circulating NS1 concentration in positive samples. We also tested the NS1 positivity of DENV-positive samples according to the Platelia Dengue NS1 Ag assay. A total of 128 samples were positive for DENV infection and were classified according to the WHO guidelines. The overall NS1 positivity was 68% according to the Platelia assay, whereas all samples were NS1-positive when analyzed with our lab-based ELISA. Fifty-four samples were positive by PCR, revealing a co-circulation of DENV1 and DENV4, and the NS1 positivity for DENV4 samples was lower than that for DENV1. The circulating NS1 concentration ranged from 7 to 284 ng/mL. Our results support previous data indicating the low efficiency of the Platelia assay to detect DENV4 infection. Moreover, this work is the first to analyze NS1 antigenemia using retrospective samples from a Brazilian outbreak. PMID:25412084

  14. [Evaluation of the diagnostic performance of Xpert MTB/RIF test for the detection of Mycobacterium tuberculosis and rifampin resistance in clinical samples].

    PubMed

    Gürsoy, Nafia Canan; Yakupoğulları, Yusuf; Tekerekoğlu, Mehmet Sait; Otlu, Barış

    2016-04-01

    Rapid and accurate detection of active tuberculosis (TB) cases is one of the most important goal of tuberculosis control programme. For this purpose, new methods are being developed to isolate, serotype and determine the drug resistance of the agent. Xpert MTB/RIF test (CepheidGeneXpert® System, USA) that has been recently developed, is a real-time polymerase chain reaction-based method which detects Mycobacterium tuberculosis complex and resistance of the strain to rifampicin (RIF) from the clinical sample directly within a couple of hours. However, there are not sufficient data about the performance of that test for extrapulmonary samples and pulmonary samples other than sputum. The aims of this study were to investigate the sensitivity, specificity, positive and negative predictive values of Xpert MTB/RIF test in detection of M. tuberculosis and the performance in the determination of rifampicin resistance of the isolates from pulmonary and extrapulmonary clinical samples. A total of 2160 clinical samples, in which 1141 (52.8%) were pulmonary and 1019 (47.2%) were extrapulmonary samples, sent to our laboratory between July 2013 to December 2014, were included in the study. Sixty seven of the evaluated samples (3.1%) were positive with microscopy (acid-fast stain; AFS), 116 samples (5.1%) were positive with culture and 98 samples (4.5%) were positive with Xpert MTB/RIF test. When the culture was considered as the reference method, the sensitivity and specificity of Xpert MTB/RIF test were determined as 73.3% and 99.3%, respectively for all samples; 77.5% and 99.5%, respectively for pulmonary samples and 63.9% and 99.2%, respectively for extrapulmonary samples. Among AFS positive samples, the sensitivity was 100% and specificity was 66.7%; whereas among AFS negative samples those values were 40.4% and 99.4%, respectively. Among all the samples involved in the study, RIF resistance was determined only in three samples with Xpert MTB/ RIF test and that was also

  15. Seeking health information on the web: positive hypothesis testing.

    PubMed

    Kayhan, Varol Onur

    2013-04-01

    The goal of this study is to investigate positive hypothesis testing among consumers of health information when they search the Web. After demonstrating the extent of positive hypothesis testing using Experiment 1, we conduct Experiment 2 to test the effectiveness of two debiasing techniques. A total of 60 undergraduate students searched a tightly controlled online database developed by the authors to test the validity of a hypothesis. The database had four abstracts that confirmed the hypothesis and three abstracts that disconfirmed it. Findings of Experiment 1 showed that majority of participants (85%) exhibited positive hypothesis testing. In Experiment 2, we found that the recommendation technique was not effective in reducing positive hypothesis testing since none of the participants assigned to this server could retrieve disconfirming evidence. Experiment 2 also showed that the incorporation technique successfully reduced positive hypothesis testing since 75% of the participants could retrieve disconfirming evidence. Positive hypothesis testing on the Web is an understudied topic. More studies are needed to validate the effectiveness of the debiasing techniques discussed in this study and develop new techniques. Search engine developers should consider developing new options for users so that both confirming and disconfirming evidence can be presented in search results as users test hypotheses using search engines. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  16. 40 CFR 133.104 - Sampling and test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 22 2011-07-01 2011-07-01 false Sampling and test procedures. 133.104 Section 133.104 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS SECONDARY TREATMENT REGULATION § 133.104 Sampling and test procedures. (a) Sampling and test procedures for...

  17. 40 CFR 133.104 - Sampling and test procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 21 2010-07-01 2010-07-01 false Sampling and test procedures. 133.104 Section 133.104 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS SECONDARY TREATMENT REGULATION § 133.104 Sampling and test procedures. (a) Sampling and test procedures for...

  18. 40 CFR 133.104 - Sampling and test procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 23 2012-07-01 2012-07-01 false Sampling and test procedures. 133.104 Section 133.104 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS SECONDARY TREATMENT REGULATION § 133.104 Sampling and test procedures. (a) Sampling and test procedures for...

  19. 16 CFR Figure 7 to Part 1203 - Typical Test Apparatus for Positional Stability Test

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Typical Test Apparatus for Positional Stability Test 7 Figure 7 to Part 1203 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER...—Typical Test Apparatus for Positional Stability Test ER10MR98.007 ...

  20. 16 CFR Figure 7 to Part 1203 - Typical Test Apparatus for Positional Stability Test

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Typical Test Apparatus for Positional Stability Test 7 Figure 7 to Part 1203 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER...—Typical Test Apparatus for Positional Stability Test ER10MR98.007 ...

  1. Reliability of three bulk-tank antimicrobial residue detection assays used to test individual milk samples from cows with mild clinical mastitis.

    PubMed

    Gibbons-Burgener, S N; Kaneene, J B; Lloyd, J W; Leykam, J F; Erskine, R J

    2001-11-01

    To determine the likelihood of false-positive results when testing milk samples from individual cows by use of 3 commercially available assays (Penzyme MilkTest and the SNAP beta-lactam and Delvo-SP assays) labeled for use with commingled milk. Milk samples from 111 cows with mild clinical mastitis. Cows were randomly assigned to the control (no antimicrobials) or intramammary treatment group. Posttreatment milk samples were collected at the first milking after the labeled withholding period or an equivalent time for controls, randomly ordered, and tested twice by use of each assay and once by use of high-performance liquid chromatography. Sensitivity, specificity, and positive and negative predictive values were determined for each assay. Concordance of results for the same sample was assessed for each assay by calculating kappa. Sensitivities of the Delvo-SP and SNAP lactam assays were > 90%, whereas the sensitivity of the Penzyme Milk Test was 60%. Positive predictive values (range, 39.29 to 73.68%) were poor for all 3 assays. Concordance of test results was excellent for the SNAP beta-lactam and Delvo-SP assays (kappa = 0.846 and 0.813, respectively) but was less for the Penzyme MilkTest (kappa = 0.545). Because of the low positive predictive values, these 3 assays may not be useful for detecting violative antimicrobial residues in individual milk samples from cows treated for mild clinical mastitis. However, repeatability of each assay was considered good to excellent.

  2. Initial clinical laboratory experience in noninvasive prenatal testing for fetal aneuploidy from maternal plasma DNA samples.

    PubMed

    Futch, Tracy; Spinosa, John; Bhatt, Sucheta; de Feo, Eileen; Rava, Richard P; Sehnert, Amy J

    2013-06-01

    The aim of this study is to report the experience of noninvasive prenatal DNA testing using massively parallel sequencing in an accredited clinical laboratory. Laboratory information was examined for blood samples received for testing between February and November 2012 for chromosome 21 (Chr21), Chr18, and Chr13. Monosomy X (MX) testing was available from July 2012 for cystic hygroma indication. Outcomes were collected from providers on samples with positive results. There were 5974 samples tested, and results were issued within an average of 5.1 business days. Aneuploidy was detected in 284 (4.8%) samples (155 Chr21, 66 Chr18, 19 Chr13, 40 MX, and four double aneuploidy). Follow-ups are available for 245/284 (86%), and 77/284 (27.1%) are confirmed, including one double-aneuploidy case concordant with cytogenetics from maternal malignancy. Fourteen (0.2%) discordant (putative false-positive) results (one Chr21, six Chr18, three Chr13, three MX, and one Chr21/13) have been identified. Five (0.08%) false-negative cases are reported (two trisomy 21, two trisomy 18, and one MX). In 170 (2.8%) cases, the result for a single chromosome was indefinite. This report suggests that clinical testing of maternal cell-free DNA for fetal aneuploidy operates within performance parameters established in validation studies. Noninvasive prenatal testing is sensitive to biological contributions from placental and maternal sources. ©2013 Verinata Health, Inc. Prenatal Diagnosis published by John Wiley & Sons, Ltd.

  3. Is it time to sound an alarm about false-positive cell-free DNA testing for fetal aneuploidy?

    PubMed

    Mennuti, Michael T; Cherry, Athena M; Morrissette, Jennifer J D; Dugoff, Lorraine

    2013-11-01

    Testing cell-free DNA (cfDNA) in maternal blood samples has been shown to have very high sensitivity for the detection of fetal aneuploidy with very low false-positive results in high-risk patients who undergo invasive prenatal diagnosis. Recent observation in clinical practice of several cases of positive cfDNA tests for trisomy 18 and trisomy 13, which were not confirmed by cytogenetic testing of the pregnancy, may reflect a limitation of the positive predictive value of this quantitative testing, particularly when it is used to detect rare aneuploidies. Analysis of a larger number of false-positive cases is needed to evaluate whether these observations reflect the positive predictive value that should be expected. Infrequently, mechanisms (such as low percentage mosaicism or confined placental mosaicism) might also lead to positive cfDNA testing that is not concordant with standard prenatal cytogenetic diagnosis. The need to explore these and other possible causes of false-positive cfDNA testing is exemplified by 2 of these cases. Additional evaluation of cfDNA testing in clinical practice and a mechanism for the systematic reporting of false-positive and false-negative cases will be important before this test is offered widely to the general population of low-risk obstetric patients. In the meantime, incorporating information about the positive predictive value in pretest counseling and in clinical laboratory reports is recommended. These experiences reinforce the importance of offering invasive testing to confirm cfDNA results before parental decision-making. Copyright © 2013 Mosby, Inc. All rights reserved.

  4. An assessment of false positive rates for malaria rapid diagnostic tests caused by non-Plasmodium infectious agents and immunological factors.

    PubMed

    Gatton, Michelle L; Ciketic, Sadmir; Barnwell, John W; Cheng, Qin; Chiodini, Peter L; Incardona, Sandra; Bell, David; Cunningham, Jane; González, Iveth J

    2018-01-01

    Malaria rapid diagnostic tests (RDTs) can produce false positive (FP) results in patients with human African trypanosomiasis and rheumatoid factor (RF), but specificity against other infectious agents and immunological factors is largely unknown. Low diagnostic specificity caused by cross-reactivity may lead to over-estimates of the number of malaria cases and over-use of antimalarial drugs, at the cost of not diagnosing and treating the true underlying condition. Data from the WHO Malaria RDT Product Testing Programme was analysed to assess FP rates of 221 RDTs against four infectious agents (Chagas, dengue, Leishmaniasis and Schistosomiasis) and four immunological factors (anti-nuclear antibody, human anti-mouse antibody (HAMA), RF and rapid plasma regain). Only RDTs with a FP rate against clean negative samples less than 10% were included. Paired t-tests were used to compare product-specific FP rates on clean negative samples and samples containing non-Plasmodium infectious agents and immunological factors. Forty (18%) RDTs showed no FP results against any tested infectious agent or immunological factor. In the remaining RDTs significant and clinically relevant increases in FP rates were observed for samples containing HAMA and RF (P<0.001). There were significant correlations between product-matched FP rates for RF and HAMA on all RDT test bands (P<0.001), and FP rates for each infectious agent and immunological factor were also correlated between test bands of combination RDTs (P≤0.002). False positive results against non-Plasmodium infectious agents and immunological factors does not appear to be a universal property of malaria RDTs. However, since many malaria RDTs have elevated FP rates against HAMA and RF positive samples practitioners may need to consider the possibility of false positive results for malaria in patients with conditions that stimulate HAMA or RF.

  5. 49 CFR 219.605 - Positive drug test results; procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.605 Positive drug test results; procedures. (a) [Reserved] (b) Procedures for administrative... 49 Transportation 4 2012-10-01 2012-10-01 false Positive drug test results; procedures. 219.605...

  6. 49 CFR 219.605 - Positive drug test results; procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.605 Positive drug test results; procedures. (a) [Reserved] (b) Procedures for administrative... 49 Transportation 4 2010-10-01 2010-10-01 false Positive drug test results; procedures. 219.605...

  7. 49 CFR 219.605 - Positive drug test results; procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.605 Positive drug test results; procedures. (a) [Reserved] (b) Procedures for administrative... 49 Transportation 4 2011-10-01 2011-10-01 false Positive drug test results; procedures. 219.605...

  8. 49 CFR 219.605 - Positive drug test results; procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.605 Positive drug test results; procedures. (a) [Reserved] (b) Procedures for administrative... 49 Transportation 4 2013-10-01 2013-10-01 false Positive drug test results; procedures. 219.605...

  9. 49 CFR 219.605 - Positive drug test results; procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Random Alcohol and Drug Testing Programs § 219.605 Positive drug test results; procedures. (a) [Reserved] (b) Procedures for administrative... 49 Transportation 4 2014-10-01 2014-10-01 false Positive drug test results; procedures. 219.605...

  10. Testing HIV positive in pregnancy: A phenomenological study of women's experiences.

    PubMed

    Lingen-Stallard, Andrew; Furber, Christine; Lavender, Tina

    2016-04-01

    globally women receive HIV testing in pregnancy; however, limited information is available on their experiences of this potentially life-changing event. This study aims to explore women's experiences of receiving a positive HIV test result following antenatal screening. a qualitative, phenomenological approach. two public National Health Service (NHS) hospitals and HIV support organisations. a purposive sampling strategy was used. Thirteen black African women with a positive HIV result, in England, participated. data were collected using in-depth semi-structured interviews. An interpretive phenomenological approach to data analysis was used. the emergent phenomenon was transition and transformation of 'being,' as women accepted HIV as part of their lives. Paired themes support the phenomenon: shock and disbelief; anger and turmoil; stigma and confidentiality issues; acceptance and resilience. Women had extreme reactions to their positive HIV diagnosis, compounded by the cultural belief that they would die. Initial disbelief of the unexpected result developed into sadness at the loss of their old self. Turmoil was evident, as women considered termination of pregnancy, self-harm and suicide. Women felt isolated from others and relationship breakdowns often occurred. Most reported the pervasiveness of stigma, and how this was managed alongside living with HIV. Coping strategies included keeping HIV 'secret' and making their child(ren) the prime focus of life. Growing resilience was apparent with time. this study gives midwives unique understanding of the complexities and major implications for women who tested positive for HIV. Women's experiences resonated with processes of bereavement, providing useful insight into a transitional and transformational period, during which appropriate support can be targeted. midwives are crucial in improving the experience of women when they test HIV positive and to do this they need to be appropriately trained. Midwives need to

  11. Positive train control test bed interoperability upgrades.

    DOT National Transportation Integrated Search

    2013-02-01

    Transportation Technology Center, Inc. (TTCI) upgraded the Positive Train Control (PTC) Test Bed to support additional PTC testing configurations under Federal Railroad Administration (FRA) Task Order 270. The scope of work provided additional PTC Co...

  12. Approximate sample size formulas for the two-sample trimmed mean test with unequal variances.

    PubMed

    Luh, Wei-Ming; Guo, Jiin-Huarng

    2007-05-01

    Yuen's two-sample trimmed mean test statistic is one of the most robust methods to apply when variances are heterogeneous. The present study develops formulas for the sample size required for the test. The formulas are applicable for the cases of unequal variances, non-normality and unequal sample sizes. Given the specified alpha and the power (1-beta), the minimum sample size needed by the proposed formulas under various conditions is less than is given by the conventional formulas. Moreover, given a specified size of sample calculated by the proposed formulas, simulation results show that Yuen's test can achieve statistical power which is generally superior to that of the approximate t test. A numerical example is provided.

  13. A novel approach for small sample size family-based association studies: sequential tests.

    PubMed

    Ilk, Ozlem; Rajabli, Farid; Dungul, Dilay Ciglidag; Ozdag, Hilal; Ilk, Hakki Gokhan

    2011-08-01

    In this paper, we propose a sequential probability ratio test (SPRT) to overcome the problem of limited samples in studies related to complex genetic diseases. The results of this novel approach are compared with the ones obtained from the traditional transmission disequilibrium test (TDT) on simulated data. Although TDT classifies single-nucleotide polymorphisms (SNPs) to only two groups (SNPs associated with the disease and the others), SPRT has the flexibility of assigning SNPs to a third group, that is, those for which we do not have enough evidence and should keep sampling. It is shown that SPRT results in smaller ratios of false positives and negatives, as well as better accuracy and sensitivity values for classifying SNPs when compared with TDT. By using SPRT, data with small sample size become usable for an accurate association analysis.

  14. The cost of large numbers of hypothesis tests on power, effect size and sample size.

    PubMed

    Lazzeroni, L C; Ray, A

    2012-01-01

    Advances in high-throughput biology and computer science are driving an exponential increase in the number of hypothesis tests in genomics and other scientific disciplines. Studies using current genotyping platforms frequently include a million or more tests. In addition to the monetary cost, this increase imposes a statistical cost owing to the multiple testing corrections needed to avoid large numbers of false-positive results. To safeguard against the resulting loss of power, some have suggested sample sizes on the order of tens of thousands that can be impractical for many diseases or may lower the quality of phenotypic measurements. This study examines the relationship between the number of tests on the one hand and power, detectable effect size or required sample size on the other. We show that once the number of tests is large, power can be maintained at a constant level, with comparatively small increases in the effect size or sample size. For example at the 0.05 significance level, a 13% increase in sample size is needed to maintain 80% power for ten million tests compared with one million tests, whereas a 70% increase in sample size is needed for 10 tests compared with a single test. Relative costs are less when measured by increases in the detectable effect size. We provide an interactive Excel calculator to compute power, effect size or sample size when comparing study designs or genome platforms involving different numbers of hypothesis tests. The results are reassuring in an era of extreme multiple testing.

  15. Versatile, low-cost, computer-controlled, sample positioning system for vacuum applications

    NASA Technical Reports Server (NTRS)

    Vargas-Aburto, Carlos; Liff, Dale R.

    1991-01-01

    A versatile, low-cost, easy to implement, microprocessor-based motorized positioning system (MPS) suitable for accurate sample manipulation in a Second Ion Mass Spectrometry (SIMS) system, and for other ultra-high vacuum (UHV) applications was designed and built at NASA LeRC. The system can be operated manually or under computer control. In the latter case, local, as well as remote operation is possible via the IEEE-488 bus. The position of the sample can be controlled in three linear orthogonal and one angular coordinates.

  16. Confirmatory analysis of field-presumptive GSR test sample using SEM/EDS

    NASA Astrophysics Data System (ADS)

    Toal, Sarah J.; Niemeyer, Wayne D.; Conte, Sean; Montgomery, Daniel D.; Erikson, Gregory S.

    2014-09-01

    RedXDefense has developed an automated red-light/green-light field presumptive lead test using a sampling pad which can be subsequently processed in a Scanning Electron Microscope for GSR confirmation. The XCAT's sampling card is used to acquire a sample from a suspect's hands on the scene and give investigators an immediate presumptive as to the presence of lead possibly from primer residue. Positive results can be obtained after firing as little as one shot. The same sampling card can then be sent to a crime lab and processed on the SEM for GSR following ASTM E-1588-10 Standard Guide for Gunshot Residue Analysis by Scanning Electron Microscopy/Energy Dispersive X-Ray Spectrometry, in the same manner as the existing tape lifts currently used in the field. Detection of GSR-characteristic particles (fused lead, barium, and antimony) as small as 0.8 microns (0.5 micron resolution) has been achieved using a JEOL JSM-6480LV SEM equipped with an Oxford Instruments INCA EDS system with a 50mm2 SDD detector, 350X magnification, in low-vacuum mode and in high vacuum mode after coating with carbon in a sputter coater. GSR particles remain stable on the sampling pad for a minimum of two months after chemical exposure (long term stability tests are in progress). The presumptive result provided by the XCAT yields immediate actionable intelligence to law enforcement to facilitate their investigation, without compromising the confirmatory test necessary to further support the investigation and legal case.

  17. 7 CFR 28.952 - Testing of samples.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Testing of samples. 28.952 Section 28.952 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... processing tests of the properties of cotton samples and report the results thereof to the persons from whom...

  18. High test positivity and low positive predictive value for colorectal cancer of continued faecal occult blood test screening after negative colonoscopy.

    PubMed

    Brown, Jeremy P; Wooldrage, Kate; Wright, Suzanne; Nickerson, Claire; Cross, Amanda J; Atkin, Wendy S

    2018-06-01

    Objectives The English Bowel Cancer Screening Programme offers biennial guaiac faecal occult blood test (gFOBT) screening to 60-74-year-olds. Participants with positive results are referred for follow-up, but many do not have significant findings. If they remain age eligible, these individuals are reinvited for gFOBT screening. We evaluated the performance of repeat screening in this group. Methods We analysed data on programme participants reinvited to gFOBT screening after either previous negative gFOBT ( n = 327,542), or positive gFOBT followed by a diagnostic investigation negative for colorectal cancer (CRC) or adenomas requiring surveillance ( n = 42,280). Outcomes calculated were uptake, test positivity, yield of CRC, and positive predictive value (PPV) of gFOBT for CRC. Results For participants with a previous negative gFOBT, uptake in the subsequent screening round was 87.5%, positivity was 1.3%, yield of CRC was 0.112% of those adequately screened, and the PPV of gFOBT for CRC was 9.1%. After a positive gFOBT and a negative diagnostic investigation, uptake in the repeat screening round was 82.6%, positivity was 11.3%, CRC yield was 0.172% of participants adequately screened, and the PPV of gFOBT for CRC was 1.7%. Conclusion With high positivity and low PPV for CRC, the suitability of routine repeat gFOBT screening in two years among individuals with a previous positive test and a negative diagnostic examination needs to be carefully considered.

  19. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false OTC test sample collection systems for drugs of... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a device...

  20. Consensus for second-order multi-agent systems with position sampled data

    NASA Astrophysics Data System (ADS)

    Wang, Rusheng; Gao, Lixin; Chen, Wenhai; Dai, Dameng

    2016-10-01

    In this paper, the consensus problem with position sampled data for second-order multi-agent systems is investigated. The interaction topology among the agents is depicted by a directed graph. The full-order and reduced-order observers with position sampled data are proposed, by which two kinds of sampled data-based consensus protocols are constructed. With the provided sampled protocols, the consensus convergence analysis of a continuous-time multi-agent system is equivalently transformed into that of a discrete-time system. Then, by using matrix theory and a sampled control analysis method, some sufficient and necessary consensus conditions based on the coupling parameters, spectrum of the Laplacian matrix and sampling period are obtained. While the sampling period tends to zero, our established necessary and sufficient conditions are degenerated to the continuous-time protocol case, which are consistent with the existing result for the continuous-time case. Finally, the effectiveness of our established results is illustrated by a simple simulation example. Project supported by the Natural Science Foundation of Zhejiang Province, China (Grant No. LY13F030005) and the National Natural Science Foundation of China (Grant No. 61501331).

  1. Benefits of expressive writing in reducing test anxiety: A randomized controlled trial in Chinese samples.

    PubMed

    Shen, Lujun; Yang, Lei; Zhang, Jing; Zhang, Meng

    2018-01-01

    To explore the effect of expressive writing of positive emotions on test anxiety among senior-high-school students. The Test Anxiety Scale (TAS) was used to assess the anxiety level of 200 senior-high-school students. Seventy-five students with high anxiety were recruited and divided randomly into experimental and control groups. Each day for 30 days, the experimental group engaged in 20 minutes of expressive writing of positive emotions, while the control group was asked to merely write down their daily events. A second test was given after the month-long experiment to analyze whether there had been a reduction in anxiety among the sample. Quantitative data was obtained from TAS scores. The NVivo10.0 software program was used to examine the frequency of particular word categories used in participants' writing manuscripts. Senior-high-school students indicated moderate to high test anxiety. There was a significant difference in post-test results (P < 0.001), with the experimental group scoring obviously lower than the control group. The interaction effect of group and gender in the post-test results was non-significant (P > 0.05). Students' writing manuscripts were mainly encoded on five code categories: cause, anxiety manifestation, positive emotion, insight and evaluation. There was a negative relation between positive emotion, insight codes and test anxiety. There were significant differences in the positive emotion, anxiety manifestation, and insight code categories between the first 10 days' manuscripts and the last 10 days' ones. Long-term expressive writing of positive emotions appears to help reduce test anxiety by using insight and positive emotion words for Chinese students. Efficient and effective intervention programs to ease test anxiety can be designed based on this study.

  2. Benefits of expressive writing in reducing test anxiety: A randomized controlled trial in Chinese samples

    PubMed Central

    Zhang, Jing; Zhang, Meng

    2018-01-01

    Purpose To explore the effect of expressive writing of positive emotions on test anxiety among senior-high-school students. Methods The Test Anxiety Scale (TAS) was used to assess the anxiety level of 200 senior-high-school students. Seventy-five students with high anxiety were recruited and divided randomly into experimental and control groups. Each day for 30 days, the experimental group engaged in 20 minutes of expressive writing of positive emotions, while the control group was asked to merely write down their daily events. A second test was given after the month-long experiment to analyze whether there had been a reduction in anxiety among the sample. Quantitative data was obtained from TAS scores. The NVivo10.0 software program was used to examine the frequency of particular word categories used in participants’ writing manuscripts. Results Senior-high-school students indicated moderate to high test anxiety. There was a significant difference in post-test results (P < 0.001), with the experimental group scoring obviously lower than the control group. The interaction effect of group and gender in the post-test results was non-significant (P > 0.05). Students’ writing manuscripts were mainly encoded on five code categories: cause, anxiety manifestation, positive emotion, insight and evaluation. There was a negative relation between positive emotion, insight codes and test anxiety. There were significant differences in the positive emotion, anxiety manifestation, and insight code categories between the first 10 days’ manuscripts and the last 10 days’ ones. Conclusions Long-term expressive writing of positive emotions appears to help reduce test anxiety by using insight and positive emotion words for Chinese students. Efficient and effective intervention programs to ease test anxiety can be designed based on this study. PMID:29401473

  3. 40 CFR 205.57-2 - Test vehicle sample selection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Test vehicle sample selection. 205.57... vehicle sample selection. (a) Vehicles comprising the batch sample which are required to be tested... test request from a batch of vehicles of the category or configuration specified in the test request...

  4. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    PubMed

    Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz

    2015-01-01

    Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.

  5. The positive and negative consequences of multiple-choice testing.

    PubMed

    Roediger, Henry L; Marsh, Elizabeth J

    2005-09-01

    Multiple-choice tests are commonly used in educational settings but with unknown effects on students' knowledge. The authors examined the consequences of taking a multiple-choice test on a later general knowledge test in which students were warned not to guess. A large positive testing effect was obtained: Prior testing of facts aided final cued-recall performance. However, prior testing also had negative consequences. Prior reading of a greater number of multiple-choice lures decreased the positive testing effect and increased production of multiple-choice lures as incorrect answers on the final test. Multiple-choice testing may inadvertently lead to the creation of false knowledge.

  6. 16 CFR Figure 7 to Part 1203 - Typical Test Apparatus for Positional Stability Test

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Typical Test Apparatus for Positional Stability Test 7 Figure 7 to Part 1203 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY STANDARD FOR BICYCLE HELMETS Pt. 1203, Fig. 7 Figure 7 to Part 1203—Typical Test Apparatus for Positional...

  7. 16 CFR Figure 7 to Part 1203 - Typical Test Apparatus for Positional Stability Test

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Typical Test Apparatus for Positional Stability Test 7 Figure 7 to Part 1203 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY STANDARD FOR BICYCLE HELMETS Pt. 1203, Fig. 7 Figure 7 to Part 1203—Typical Test Apparatus for Positional...

  8. 16 CFR Figure 7 to Part 1203 - Typical Test Apparatus for Positional Stability Test

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Typical Test Apparatus for Positional Stability Test 7 Figure 7 to Part 1203 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY STANDARD FOR BICYCLE HELMETS Pt. 1203, Fig. 7 Figure 7 to Part 1203—Typical Test Apparatus for Positional...

  9. The impact of induced positive mood on symptomatic behaviour in eating disorders. An experimental, AB/BA crossover design testing a multimodal presentation during a test-meal.

    PubMed

    Cardi, Valentina; Esposito, Mirko; Clarke, Ariana; Schifano, Sylvia; Treasure, Janet

    2015-04-01

    The aim of this study was to test the impact of a multimodal positive mood vodcast including pleasant images, background uplifting music and a script designed to elicit positive mood on eating disorders-related symptoms in participants suffering from an Eating Disorder (ED) and healthy controls (HCs). Forty-two women with an ED (Anorexia Nervosa [AN]: N = 19; Bulimia Nervosa [BN]: N = 23) and 36 HCs were included in an AB/BA cross-over design which compared the use of a positive mood induction procedure ("positive mood vodcast") with a control condition (i.e. blue static background, neutral music, and script describing objective facts) during a test-meal. Self-report measures and behavioural tasks were completed before and after the test-meal. The positive mood vodcast was associated with greater consumption of the test meal in the AN group; reduced vigilance to food stimuli and lower anxiety in the BN sample; and no significant changes in the HC group. The use of a positive mood vodcast was associated with some beneficial effects in the context of an experimental test-meal in participants with an ED. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Emperical Tests of Acceptance Sampling Plans

    NASA Technical Reports Server (NTRS)

    White, K. Preston, Jr.; Johnson, Kenneth L.

    2012-01-01

    Acceptance sampling is a quality control procedure applied as an alternative to 100% inspection. A random sample of items is drawn from a lot to determine the fraction of items which have a required quality characteristic. Both the number of items to be inspected and the criterion for determining conformance of the lot to the requirement are given by an appropriate sampling plan with specified risks of Type I and Type II sampling errors. In this paper, we present the results of empirical tests of the accuracy of selected sampling plans reported in the literature. These plans are for measureable quality characteristics which are known have either binomial, exponential, normal, gamma, Weibull, inverse Gaussian, or Poisson distributions. In the main, results support the accepted wisdom that variables acceptance plans are superior to attributes (binomial) acceptance plans, in the sense that these provide comparable protection against risks at reduced sampling cost. For the Gaussian and Weibull plans, however, there are ranges of the shape parameters for which the required sample sizes are in fact larger than the corresponding attributes plans, dramatically so for instances of large skew. Tests further confirm that the published inverse-Gaussian (IG) plan is flawed, as reported by White and Johnson (2011).

  11. Mars Science Laboratory Sample Acquisition, Sample Processing and Handling: Subsystem Design and Test Challenges

    NASA Technical Reports Server (NTRS)

    Jandura, Louise

    2010-01-01

    The Sample Acquisition/Sample Processing and Handling subsystem for the Mars Science Laboratory is a highly-mechanized, Rover-based sampling system that acquires powdered rock and regolith samples from the Martian surface, sorts the samples into fine particles through sieving, and delivers small portions of the powder into two science instruments inside the Rover. SA/SPaH utilizes 17 actuated degrees-of-freedom to perform the functions needed to produce 5 sample pathways in support of the scientific investigation on Mars. Both hardware redundancy and functional redundancy are employed in configuring this sampling system so some functionality is retained even with the loss of a degree-of-freedom. Intentional dynamic environments are created to move sample while vibration isolators attenuate this environment at the sensitive instruments located near the dynamic sources. In addition to the typical flight hardware qualification test program, two additional types of testing are essential for this kind of sampling system: characterization of the intentionally-created dynamic environment and testing of the sample acquisition and processing hardware functions using Mars analog materials in a low pressure environment. The overall subsystem design and configuration are discussed along with some of the challenges, tradeoffs, and lessons learned in the areas of fault tolerance, intentional dynamic environments, and special testing

  12. Can human papillomavirus DNA testing of self-collected vaginal samples compare with physician-collected cervical samples and cytology for cervical cancer screening in developing countries?

    PubMed Central

    Bhatla, Neerja; Dar, Lalit; Patro, A. Rajkumar; Kumar, Pankaj; Kriplani, Alka; Gulati, Arti; Iyer, Venkateswaran K.; Mathur, Sandeep R.; Sreenivas, Vishnubhatla; Shah, Keerti V.; Gravitt, Patti E.

    2013-01-01

    Background To determine human papillomavirus (HPV) types by polymerase chain reaction (PCR)-reverse line blot assay and examine the concordance between HPV by Hybrid Capture 2 (HC2) and PCR on self-collected vaginal and physician-collected cervical samples and cytology. Methods This was a cross-sectional study of 546 sexually active women aged ≥30 years with persistent vaginal discharge, intermenstrual or postcoital bleeding or an unhealthy cervix. Participants self-collected vaginal samples (HPV-S) and physicians collected cervical samples for conventional Pap smear and HPV DNA (HPV-P) testing and performed colposcopy, with directed biopsy, if indicated. HPV testing and genotyping was done by HC2 and PCR reverse line blot assay. Concordance between HC2 and PCR results of self- and physician-collected samples was determined using a Kappa statistic (κ) and Chi-square test. Results Complete data were available for 512 sets with 98% of women providing a satisfactory self-sample. PCR detected oncogenic HPV in 12.3% of self- and 13.0% of physician-collected samples. Overall, there was 93.8% agreement between physician-collected and self-samples (κ = 76.31%, 95% confidence interval [CI]: 64.97–82.29%, p = 0.04)—complete concordance in 473 cases (57 positive, 416 negative), partial concordance in seven pairs and discordance in 32 pairs. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of self-sampling for detection of cervical intraepithelial neoplasia (CIN)2+ disease were 82.5%, 93.6%, 52.4% and 98.4%, respectively; for physician-sampling they were 87.5%, 93.2%, 52.2% and 98.9%, respectively; and for cytology they were 77.5%, 87.3%, 34.1% and 97.9%, respectively. Concordance between HC2 and PCR was 90.9% for self-samples (κ = 63.7%, 95% CI: 55.2–72.2%) and 95.3% for physician-collected samples (κ = 80.4%, 95% CI: 71.8–89.0%). Conclusions Self-HPV sampling compares favourably with physician-sampling and

  13. 16 CFR 1203.15 - Positional stability test (roll-off resistance).

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Positional stability test (roll-off... SAFETY ACT REGULATIONS SAFETY STANDARD FOR BICYCLE HELMETS The Standard § 1203.15 Positional stability test (roll-off resistance). (a) Test equipment. (1) Headforms. The test headforms shall comply with the...

  14. 16 CFR 1203.15 - Positional stability test (roll-off resistance).

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Positional stability test (roll-off... SAFETY ACT REGULATIONS SAFETY STANDARD FOR BICYCLE HELMETS The Standard § 1203.15 Positional stability test (roll-off resistance). (a) Test equipment. (1) Headforms. The test headforms shall comply with the...

  15. 16 CFR 1203.15 - Positional stability test (roll-off resistance).

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Positional stability test (roll-off... SAFETY ACT REGULATIONS SAFETY STANDARD FOR BICYCLE HELMETS The Standard § 1203.15 Positional stability test (roll-off resistance). (a) Test equipment. (1) Headforms. The test headforms shall comply with the...

  16. Evaluation of HIV testing algorithms in Ethiopia: the role of the tie-breaker algorithm and weakly reacting test lines in contributing to a high rate of false positive HIV diagnoses.

    PubMed

    Shanks, Leslie; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Pirou, Erwan; Ritmeijer, Koert; Masiga, Johnson; Abebe, Almaz

    2015-02-03

    In Ethiopia a tiebreaker algorithm using 3 rapid diagnostic tests (RDTs) in series is used to diagnose HIV. Discordant results between the first 2 RDTs are resolved by a third 'tiebreaker' RDT. Médecins Sans Frontières uses an alternate serial algorithm of 2 RDTs followed by a confirmation test for all double positive RDT results. The primary objective was to compare the performance of the tiebreaker algorithm with a serial algorithm, and to evaluate the addition of a confirmation test to both algorithms. A secondary objective looked at the positive predictive value (PPV) of weakly reactive test lines. The study was conducted in two HIV testing sites in Ethiopia. Study participants were recruited sequentially until 200 positive samples were reached. Each sample was re-tested in the laboratory on the 3 RDTs and on a simple to use confirmation test, the Orgenics Immunocomb Combfirm® (OIC). The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. 2620 subjects were included with a HIV prevalence of 7.7%. Each of the 3 RDTs had an individual specificity of at least 99%. The serial algorithm with 2 RDTs had a single false positive result (1 out of 204) to give a PPV of 99.5% (95% CI 97.3%-100%). The tiebreaker algorithm resulted in 16 false positive results (PPV 92.7%, 95% CI: 88.4%-95.8%). Adding the OIC confirmation test to either algorithm eliminated the false positives. All the false positives had at least one weakly reactive test line in the algorithm. The PPV of weakly reacting RDTs was significantly lower than those with strongly positive test lines. The risk of false positive HIV diagnosis in a tiebreaker algorithm is significant. We recommend abandoning the tie-breaker algorithm in favour of WHO recommended serial or parallel algorithms, interpreting weakly reactive test lines as indeterminate results requiring further testing except in the setting of blood transfusion, and most importantly, adding a confirmation test

  17. Acute toxic tests of rainwater samples using Daphnia magna.

    PubMed

    Sakai, Manabu

    2006-06-01

    Rainwater samples were collected at Isogo Ward of Yokohama City, Japan, from 23 June to 31 July 2003. The toxic potency of pollutants present in 13 rainwater samples was tested using Daphnia magna. Most test animals died within 48 h in five test solutions that were prepared from rainwater samples. On the other hand, when nonpolar compounds such as pesticides were removed from rainwater samples before the toxic tests, mortalities in all test solutions were less than 10%. Eight kinds of pesticides were detected in rainwater samples. The highest concentration was of dichlorvos, at 0.74 microg/L. Results indicated that insecticides in rainwater sometimes lethally affected D. magna and that toxic potency of insecticides that are present in rainwater constitutes an important problem for environmental protection.

  18. New prior sampling methods for nested sampling - Development and testing

    NASA Astrophysics Data System (ADS)

    Stokes, Barrie; Tuyl, Frank; Hudson, Irene

    2017-06-01

    Nested Sampling is a powerful algorithm for fitting models to data in the Bayesian setting, introduced by Skilling [1]. The nested sampling algorithm proceeds by carrying out a series of compressive steps, involving successively nested iso-likelihood boundaries, starting with the full prior distribution of the problem parameters. The "central problem" of nested sampling is to draw at each step a sample from the prior distribution whose likelihood is greater than the current likelihood threshold, i.e., a sample falling inside the current likelihood-restricted region. For both flat and informative priors this ultimately requires uniform sampling restricted to the likelihood-restricted region. We present two new methods of carrying out this sampling step, and illustrate their use with the lighthouse problem [2], a bivariate likelihood used by Gregory [3] and a trivariate Gaussian mixture likelihood. All the algorithm development and testing reported here has been done with Mathematica® [4].

  19. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    PubMed Central

    Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M. Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz

    2015-01-01

    Background Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Methodology/Principal Findings Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). Conclusion The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study. PMID:26161864

  20. Gram-negative and -positive bacteria differentiation in blood culture samples by headspace volatile compound analysis.

    PubMed

    Dolch, Michael E; Janitza, Silke; Boulesteix, Anne-Laure; Graßmann-Lichtenauer, Carola; Praun, Siegfried; Denzer, Wolfgang; Schelling, Gustav; Schubert, Sören

    2016-12-01

    Identification of microorganisms in positive blood cultures still relies on standard techniques such as Gram staining followed by culturing with definite microorganism identification. Alternatively, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry or the analysis of headspace volatile compound (VC) composition produced by cultures can help to differentiate between microorganisms under experimental conditions. This study assessed the efficacy of volatile compound based microorganism differentiation into Gram-negatives and -positives in unselected positive blood culture samples from patients. Headspace gas samples of positive blood culture samples were transferred to sterilized, sealed, and evacuated 20 ml glass vials and stored at -30 °C until batch analysis. Headspace gas VC content analysis was carried out via an auto sampler connected to an ion-molecule reaction mass spectrometer (IMR-MS). Measurements covered a mass range from 16 to 135 u including CO2, H2, N2, and O2. Prediction rules for microorganism identification based on VC composition were derived using a training data set and evaluated using a validation data set within a random split validation procedure. One-hundred-fifty-two aerobic samples growing 27 Gram-negatives, 106 Gram-positives, and 19 fungi and 130 anaerobic samples growing 37 Gram-negatives, 91 Gram-positives, and two fungi were analysed. In anaerobic samples, ten discriminators were identified by the random forest method allowing for bacteria differentiation into Gram-negative and -positive (error rate: 16.7 % in validation data set). For aerobic samples the error rate was not better than random. In anaerobic blood culture samples of patients IMR-MS based headspace VC composition analysis facilitates bacteria differentiation into Gram-negative and -positive.

  1. Gleeble Testing of Tungsten Samples

    DTIC Science & Technology

    2013-02-01

    as a diffusion barrier to prevent the tungsten samples from fusing to the tungsten carbide inserts at elevated temperatures. After the anvils were...anvils with removable tungsten carbide inserts. The inserts were 19.05 mm (0.75 in) in diameter and 25.4 mm (1 in) long; they were purchased from...rhenium are shown in tables 6 and 7 and figure 7. The sample tested at 1300 °C, T4, partially embedded into the tungsten carbide (WC) inserts during

  2. The prevalence of positive serological tests for syphilis among elderly hospital patients.

    PubMed

    Corrado, O J; Bowie, P C; Bagnall, W E; Waugh, M A

    1989-11-01

    Serological tests for syphilis were performed on 659 elderly patients admitted to hospital medical and psychiatric departments. Positive tests were found in 23 patients (3.5% of the sample), 17 women and 6 men. Six were subsequently discovered to have been treated previously for syphilis, and one other had radiological evidence to suggest that she had been treated with bismuth in the pre-penicillin era. Difficulties were encountered in classifying the stage of infection in some patients, particularly those with significant intellectual impairment. Eleven were diagnosed as late latent syphilis, seven as probable late latent syphilis, one as tabes dorsalis, one as possible cardiovascular syphilis, one as possible meningovascular syphilis, and one as late congenital syphilis.

  3. Method and apparatus for processing a test sample to concentrate an analyte in the sample from a solvent in the sample

    DOEpatents

    Turner, Terry D.; Beller, Laurence S.; Clark, Michael L.; Klingler, Kerry M.

    1997-01-01

    A method of processing a test sample to concentrate an analyte in the sample from a solvent in the sample includes: a) boiling the test sample containing the analyte and solvent in a boiling chamber to a temperature greater than or equal to the solvent boiling temperature and less than the analyte boiling temperature to form a rising sample vapor mixture; b) passing the sample vapor mixture from the boiling chamber to an elongated primary separation tube, the separation tube having internal sidewalls and a longitudinal axis, the longitudinal axis being angled between vertical and horizontal and thus having an upper region and a lower region; c) collecting the physically transported liquid analyte on the internal sidewalls of the separation tube; and d) flowing the collected analyte along the angled internal sidewalls of the separation tube to and pass the separation tube lower region. The invention also includes passing a turbulence inducing wave through a vapor mixture to separate physically transported liquid second material from vaporized first material. Apparatus are also disclosed for effecting separations. Further disclosed is a fluidically powered liquid test sample withdrawal apparatus for withdrawing a liquid test sample from a test sample container and for cleaning the test sample container.

  4. Method and apparatus for processing a test sample to concentrate an analyte in the sample from a solvent in the sample

    DOEpatents

    Turner, T.D.; Beller, L.S.; Clark, M.L.; Klingler, K.M.

    1997-10-14

    A method of processing a test sample to concentrate an analyte in the sample from a solvent in the sample includes: (a) boiling the test sample containing the analyte and solvent in a boiling chamber to a temperature greater than or equal to the solvent boiling temperature and less than the analyte boiling temperature to form a rising sample vapor mixture; (b) passing the sample vapor mixture from the boiling chamber to an elongated primary separation tube, the separation tube having internal sidewalls and a longitudinal axis, the longitudinal axis being angled between vertical and horizontal and thus having an upper region and a lower region; (c) collecting the physically transported liquid analyte on the internal sidewalls of the separation tube; and (d) flowing the collected analyte along the angled internal sidewalls of the separation tube to and pass the separation tube lower region. The invention also includes passing a turbulence inducing wave through a vapor mixture to separate physically transported liquid second material from vaporized first material. Apparatus is also disclosed for effecting separations. Further disclosed is a fluidically powered liquid test sample withdrawal apparatus for withdrawing a liquid test sample from a test sample container and for cleaning the test sample container. 8 figs.

  5. Apparatus for testing skin samples or the like

    DOEpatents

    Holland, J.M.

    1982-08-31

    An apparatus for testing the permeability of living skin samples has a flat base with a plurality of sample-holding cavities formed in its upper surface, the samples being placed in counterbores in the cavities with the epidermis uppermost. O-rings of Teflon washers are respectively placed on the samples and a flat cover is connected to the base to press the rings against the upper surfaces of the samples. Media to maintain tissue viability and recovery of metabolites is introduced into the lower portion of the sample-holding cavities through passages in the base. Test materials are introduced through holes in the cover plate after assembly of the chamber.

  6. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a device...

  7. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a device...

  8. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a device...

  9. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a device...

  10. Phoenix Test Sample Site

    NASA Technical Reports Server (NTRS)

    2008-01-01

    This image, acquired by NASA's Phoenix Mars Lander's Surface Stereo Imager on Sol 7, the seventh day of the mission (June 1, 2008), shows the so-called 'Knave of Hearts' first-dig test area to the north of the lander. The Robotic Arm's scraping blade left a small horizontal depression above where the sample was taken.

    Scientists speculate that white material in the depression left by the dig could represent ice or salts that precipitated into the soil. This material is likely the same white material observed in the sample in the Robotic Arm's scoop.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  11. Accuracy of human papillomavirus testing on self-collected versus clinician-collected samples: a meta-analysis.

    PubMed

    Arbyn, Marc; Verdoodt, Freija; Snijders, Peter J F; Verhoef, Viola M J; Suonio, Eero; Dillner, Lena; Minozzi, Silvia; Bellisario, Cristina; Banzi, Rita; Zhao, Fang-Hui; Hillemanns, Peter; Anttila, Ahti

    2014-02-01

    Screening for human papillomavirus (HPV) infection is more effective in reducing the incidence of cervical cancer than screening using Pap smears. Moreover, HPV testing can be done on a vaginal sample self-taken by a woman, which offers an opportunity to improve screening coverage. However, the clinical accuracy of HPV testing on self-samples is not well-known. We assessed whether HPV testing on self-collected samples is equivalent to HPV testing on samples collected by clinicians. We identified relevant studies through a search of PubMed, Embase, and CENTRAL. Studies were eligible for inclusion if they fulfilled all of the following selection criteria: a cervical cell sample was self-collected by a woman followed by a sample taken by a clinician; a high-risk HPV test was done on the self-sample (index test) and HPV-testing or cytological interpretation was done on the specimen collected by the clinician (comparator tests); and the presence or absence of cervical intraepithelial neoplasia grade 2 (CIN2) or worse was verified by colposcopy and biopsy in all enrolled women or in women with one or more positive tests. The absolute accuracy for finding CIN2 or worse, or CIN grade 3 (CIN3) or worse of the index and comparator tests as well as the relative accuracy of the index versus the comparator tests were pooled using bivariate normal models and random effect models. We included data from 36 studies, which altogether enrolled 154 556 women. The absolute accuracy varied by clinical setting. In the context of screening, HPV testing on self-samples detected, on average, 76% (95% CI 69-82) of CIN2 or worse and 84% (72-92) of CIN3 or worse. The pooled absolute specificity to exclude CIN2 or worse was 86% (83-89) and 87% (84-90) to exclude CIN3 or worse. The variation of the relative accuracy of HPV testing on self-samples compared with tests on clinician-taken samples was low across settings, enabling pooling of the relative accuracy over all studies. The pooled

  12. Organizational Benchmarks for Test Utilization Performance: An Example Based on Positivity Rates for Genetic Tests.

    PubMed

    Rudolf, Joseph; Jackson, Brian R; Wilson, Andrew R; Smock, Kristi J; Schmidt, Robert L

    2017-04-01

    Health care organizations are under increasing pressure to deliver value by improving test utilization management. Many factors, including organizational factors, could affect utilization performance. Past research has focused on the impact of specific interventions in single organizations. The impact of organizational factors is unknown. The objective of this study is to determine whether testing patterns are subject to organizational effects, ie, are utilization patterns for individual tests correlated within organizations. Comparative analysis of ordering patterns (positivity rates for three genetic tests) across 659 organizations. Hierarchical regression was used to assess the impact of organizational factors after controlling for test-level factors (mutation prevalence) and hospital bed size. Test positivity rates were correlated within organizations. Organizations have a statistically significant impact on the positivity rate of three genetic tests. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  13. Research of built-in self test technology on cable-free self-positioning seismograph

    NASA Astrophysics Data System (ADS)

    Huaizhu, Z.; Lin, J.; Chen, Z.; Zhang, L.; Yang, H.; Zheng, F.

    2011-12-01

    Cable-free self-positioning seismograph is the key instrument and equipment required for deep seismic exploration in China. In order to measure the performance of seismic data acquisition systems whether meet exploration requirements , to ensure the accuracy of seismic data, and to ensure equipment reliability and stability, a built-in self test solution of the cable-free self-positioning seismic recorder is provided. Within a 24-bits Σ-Δ DAC, the seismograph can produce sine, step, pulse and other high-precision analog test signal, with dynamic range of 120dB or more, through the FPGA to control the analog multiplexer switching the input signal acquisition channels, and start the 24-bit Σ-Δ ADC in the instrument internal simultaneously to acquisition the test signal data, carries on the fast Fournier transformation by instrument internal CPU, to achieve the instrument of analysis and calculation of performance indicators, including: the equivalent noise and drift, common mode rejection ratio (CMRR), crosstalk, harmonic distortion, dynamic range, channel response consistency, detector impulse response , etc. A lot of testing experiments about the various parameters were performed and studied currently. By setting different sampling rate (1Hz, 5Hz, ..., 4kHz), each of the measurement system noise level was measured, and the maximum noise is about 0.5μV; the crosstalk between channels was tested using the 31.25Hz sine wave, the result is more than-120dB with sampling rate of 1kHz; the harmonic distortion was measured by adding the high-precision sine wave signals of different frequencies, such as 500Hz, 250 Hz, 125 Hz, 62.5 Hz, 31.25 Hz, 15.625 Hz, 7.812 Hz, 3.90625Hz, etc. the calculated results is in-118dB or more. The experimental results show that, the parameters of the cable-free self-positioning of the seismic recorder meet the technical requirements for the deep exploration, compared to the corresponding parameters with the 428XL seismograph of the French

  14. Accuracy and Cost-Effectiveness of Cervical Cancer Screening by High-Risk HPV DNA Testing of Self-Collected Vaginal Samples

    PubMed Central

    Balasubramanian, Akhila; Kulasingam, Shalini L.; Baer, Atar; Hughes, James P.; Myers, Evan R.; Mao, Constance; Kiviat, Nancy B.; Koutsky, Laura A.

    2010-01-01

    Objective Estimate the accuracy and cost-effectiveness of cervical cancer screening strategies based on high-risk HPV DNA testing of self-collected vaginal samples. Materials and Methods A subset of 1,665 women (18-50 years of age) participating in a cervical cancer screening study were screened by liquid-based cytology and by high-risk HPV DNA testing of both self-collected vaginal swab samples and clinician-collected cervical samples. Women with positive/abnormal screening test results and a subset of women with negative screening test results were triaged to colposcopy. Based on individual and combined test results, five screening strategies were defined. Estimates of sensitivity and specificity for cervical intraepithelial neoplasia grade 2 or worse were calculated and a Markov model was used to estimate the incremental cost-effectiveness ratios (ICERs) for each strategy. Results Compared to cytology-based screening, high-risk HPV DNA testing of self-collected vaginal samples was more sensitive (68%, 95%CI=58%-78% versus 85%, 95%CI=76%-94%) but less specific (89%, 95%CI=86%-91% versus 73%, 95%CI=67%-79%). A strategy of high-risk HPV DNA testing of self-collected vaginal samples followed by cytology triage of HPV positive women, was comparably sensitive (75%, 95%CI=64%-86%) and specific (88%, 95%CI=85%-92%) to cytology-based screening. In-home self-collection for high-risk HPV DNA detection followed by in-clinic cytology triage had a slightly lower lifetime cost and a slightly higher quality-adjusted life expectancy than did cytology-based screening (ICER of triennial screening compared to no screening was $9,871/QALY and $12,878/QALY, respectively). Conclusions Triennial screening by high-risk HPV DNA testing of in-home, self-collected vaginal samples followed by in-clinic cytology triage was cost-effective. PMID:20592553

  15. Estimation of sample size and testing power (part 5).

    PubMed

    Hu, Liang-ping; Bao, Xiao-lei; Guan, Xue; Zhou, Shi-guo

    2012-02-01

    Estimation of sample size and testing power is an important component of research design. This article introduced methods for sample size and testing power estimation of difference test for quantitative and qualitative data with the single-group design, the paired design or the crossover design. To be specific, this article introduced formulas for sample size and testing power estimation of difference test for quantitative and qualitative data with the above three designs, the realization based on the formulas and the POWER procedure of SAS software and elaborated it with examples, which will benefit researchers for implementing the repetition principle.

  16. Statistical approaches to account for false-positive errors in environmental DNA samples.

    PubMed

    Lahoz-Monfort, José J; Guillera-Arroita, Gurutzeta; Tingley, Reid

    2016-05-01

    Environmental DNA (eDNA) sampling is prone to both false-positive and false-negative errors. We review statistical methods to account for such errors in the analysis of eDNA data and use simulations to compare the performance of different modelling approaches. Our simulations illustrate that even low false-positive rates can produce biased estimates of occupancy and detectability. We further show that removing or classifying single PCR detections in an ad hoc manner under the suspicion that such records represent false positives, as sometimes advocated in the eDNA literature, also results in biased estimation of occupancy, detectability and false-positive rates. We advocate alternative approaches to account for false-positive errors that rely on prior information, or the collection of ancillary detection data at a subset of sites using a sampling method that is not prone to false-positive errors. We illustrate the advantages of these approaches over ad hoc classifications of detections and provide practical advice and code for fitting these models in maximum likelihood and Bayesian frameworks. Given the severe bias induced by false-negative and false-positive errors, the methods presented here should be more routinely adopted in eDNA studies. © 2015 John Wiley & Sons Ltd.

  17. Evaluation of sample stability for a quantitative faecal immunochemical test and comparison of two sample collection approaches.

    PubMed

    Mellen, Samantha; de Ferrars, Maria; Chapman, Claire; Bevan, Sarah; Turvill, James; Turnock, Daniel

    2018-01-01

    Background Faecal immunochemical testing is increasingly being used to triage symptomatic patients for suspected colorectal cancer. However, there are limited data on the effect of preanalytical factors on faecal haemoglobin when measured by faecal immunochemical testing. The aim of this work was to evaluate the stability of faecal haemoglobin in faeces and to compare two methods of faecal haemoglobin sampling for faecal immunochemical testing. Methods Six patients provided faeces for faecal haemoglobin measurement which were transferred into specialized collection devices at baseline and at 1, 2, 3 and 7 days after storage at either room temperature or 4°C. A total of 137 patients returned both faeces transferred into the specialized collection device and faeces in a standard collection pot. A quantitative immunoturbidometric method was used to measure faecal haemoglobin and results were compared categorically. Discrepant results were assessed against diagnosis. Results Faecal haemoglobin concentration declined rapidly within a day of storage at room temperature but results remained ≥10 μg Hb/g faeces in 5/6 patients after two days. A faecal haemoglobin result ≥10 μg Hb/g faeces was obtained in 4/6 patients after storage for seven days at 4°C. Results obtained when patients used specialized collection devices were significantly different from results obtained when faeces was transferred into the specialized collection device in the laboratory. Conclusion There is considerable heterogeneity in the sample stability of faecal haemoglobin; therefore, samples should be transferred rapidly into specialized collection devices to prevent false-negative results. Use of collection devices by patients can lead to false-positive results compared with their use in a laboratory.

  18. Female False Positive Exercise Stress ECG Testing - Fact Verses Fiction.

    PubMed

    Fitzgerald, Benjamin T; Scalia, William M; Scalia, Gregory M

    2018-03-07

    Exercise stress testing is a well validated cardiovascular investigation. Accuracy for treadmill stress electrocardiograph (ECG) testing has been documented at 60%. False positive stress ECGs (exercise ECG changes with non-obstructive disease on anatomical testing) are common, especially in women, limiting the effectiveness of the test. This study investigates the incidence and predictors of false positive stress ECG findings, referenced against stress echocardiography (SE) as a standard. Stress echocardiography was performed using the Bruce treadmill protocol. False positive stress ECG tests were defined as greater than 1mm of ST depression on ECG during exertion, without pain, with a normal SE. Potential causes for false positive tests were recorded before the test. Three thousand consecutive negative stress echocardiograms (1036 females, 34.5%) were analysed (age 59+/-14 years. False positive (F+) stress ECGs were documented in 565/3000 tests (18.8%). F+ stress ECGs were equally prevalent in females (194/1036, 18.7%) and males (371/1964, 18.9%, p=0.85 for the difference). Potential causes (hypertension, left ventricular hypertrophy, known coronary disease, arrhythmia, diabetes mellitus, valvular heart disease) were recorded in 36/194 (18.6%) of the female F+ ECG tests and 249/371 (68.2%) of the male F+ ECG tests (p<0.0001 for the difference). These data suggest that F+ stress ECG tests are frequent and equally common in women and men. However, most F+ stress ECGs in men can be predicted before the test, while most in women cannot. Being female may be a risk factor in itself. These data reinforce the value of stress imaging, particularly in women. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.

  19. THE NAVICULAR POSITION TEST – A RELIABLE MEASURE OF THE NAVICULAR BONE POSITION DURING REST AND LOADING

    PubMed Central

    Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard; Boesen, Morten Ilum

    2011-01-01

    Background: Lower limb injuries are a large problem in athletes. However, there is a paucity of knowledge on the relationship between alignment of the medial longitudinal arch (MLA) of the foot and development of such injuries. A reliable and valid test to quantify foot type is needed to be able to investigate the relationship between arch type and injury likelihood. Feiss Line is a valid clinical measure of the MLA. However, no study has investigated the reliability of the test. Objectives: The purpose was to describe a modified version of the Feiss Line test and to determine the intra- and inter-tester reliability of this new foot alignment test. To emphasize the purpose of the modified test, the authors have named it The Navicular Position Test. Methods: Intra- and inter-tester reliability were evaluated of The Navicular Position Test with the use of ICC (interclass correlation coefficient) and Bland-Altman limits of agreement on 43 healthy, young, subjects. Results: Inter-tester mean difference -0.35 degrees [–1.32; 0.62] p = 0.47. Bland-Altman limits of agreement –6.55 to 5.85 degrees, ICC = 0.94. Intra-tester mean difference 0.47 degrees [–0.57; 1.50] p = 0.37. Bland-Altman limits of agreement –6.15 to 7.08 degrees, ICC = 0.91. Discussion: The present data support The Navicular Position Test as a reliable test of the navicular bone position during rest and loading measured in a simple test set-up. Conclusion: The Navicular Position Test was shown to have a high intraday-, intra- and inter-tester reliability. When cut off values to categorize the MLA into planus, rectus, or cavus feet, has been determined and presented, the test could be used in prospective observational studies investigating the role of the arch type on the development of various lower limb injuries. PMID:21904698

  20. Comparison of Performance Characteristics of Aspergillus PCR in Testing a Range of Blood-Based Samples in Accordance with International Methodological Recommendations.

    PubMed

    Springer, Jan; White, P Lewis; Hamilton, Shanna; Michel, Denise; Barnes, Rosemary A; Einsele, Hermann; Löffler, Juergen

    2016-03-01

    Standardized methodologies for the molecular detection of invasive aspergillosis (IA) have been established by the European Aspergillus PCR Initiative for the testing of whole blood, serum, and plasma. While some comparison of the performance of Aspergillus PCR when testing these different sample types has been performed, no single study has evaluated all three using the recommended protocols. Standardized Aspergillus PCR was performed on 423 whole-blood pellets (WBP), 583 plasma samples, and 419 serum samples obtained from hematology patients according to the recommendations. This analysis formed a bicenter retrospective anonymous case-control study, with diagnosis according to the revised European Organization for Research and Treatment of Cancer/Invasive Fungal Infections Cooperative Group and National Institute of Allergy and Infectious Diseases Mycoses Study Group (EORTC/MSG) consensus definitions (11 probable cases and 36 controls). Values for clinical performance using individual and combined samples were calculated. For all samples, PCR positivity was significantly associated with cases of IA (for plasma, P = 0.0019; for serum, P = 0.0049; and for WBP, P = 0.0089). Plasma PCR generated the highest sensitivity (91%); the sensitivities for serum and WBP PCR were 80% and 55%, respectively. The highest specificity was achieved when testing WBP (96%), which was significantly superior to the specificities achieved when testing serum (69%, P = 0.0238) and plasma (53%, P = 0.0002). No cases were PCR negative in all specimen types, and no controls were PCR positive in all specimens. This study confirms that Aspergillus PCR testing of plasma provides robust performance while utilizing commercial automated DNA extraction processes. Combining PCR testing of different blood fractions allows IA to be both confidently diagnosed and excluded. A requirement for multiple PCR-positive plasma samples provides similar diagnostic utility and is technically less demanding. Time

  1. Guidelines for the use and interpretation of nucleic acid detection tests for Neisseria gonorrhoeae in Australia: a position paper on behalf of the Public Health Laboratory Network.

    PubMed

    Smith, David W; Tapsall, John W; Lum, Gary

    2005-01-01

    The Public Health Laboratory Network (PHLN) convened a workshop of Australian experts in Melbourne on 23 March 2005 to identify laboratory issues of relevance and suggest guidelines for use of nucleic acid detection tests (NADT) for diagnosis of gonorrhoea in Australia. The proceedings of that meeting were endorsed by the members of the PHLN and the Communicable Diseases Network of Australia. Given the present state of knowledge and experience of conditions currently existing in Australia, the following recommendations were made: Recommendation 1: Assays using detection of the cppB gene should not be used for either screening or supplemental assays. Recommendation 2: All in-house screening assays that are positive should also be positive on a reliable supplemental assay before a positive result is reported. Recommendation 3: All commercial screening assays that are positive should also be positive on a reliable supplemental assay before a positive result is reported. Recommendation 4: If a sample is positive in a screening assay but a suitable supplemental assay is negative, then the result should be reported as negative. Recommendation 5: Laboratories should ensure that the test combination they use would yield a positive predictive value of at least 90 per cent in a population with a prevalence of 1 per cent. Recommendation 6: For the purposes of test evaluation, as distinct from diagnostic testing, true positives be defined by meeting one or more of the following criteria: 1) culture positive using contemporary isolation and identification techniques; 2) positive result on NADTs directed to targets on three separate genes that are known to have discriminatory capacity; 3) sequencing of a gene known to separate gonococcal from non-gonococcal species. Recommendation 7: Inhibitor controls should be routinely included in all NADT. Recommendation 8: Cultures are the preferred test for samples from non-genital sites. If however it is necessary to perform a NADT, then

  2. Evidence of Mycobacterium tuberculosis complex bacteraemia in intradermal skin test positive cattle detected using phage-RPA.

    PubMed

    Swift, Benjamin M C; Convery, Thomas W; Rees, Catherine E D

    2016-10-02

    Bovine tuberculosis is a zoonotic infectious disease caused by Mycobacterium bovis that affects cattle and can cause tuberculosis in a range of wildlife animals. A bacteriophage-based method combined with PCR (phage-PCR) has been recently used to detect and identify viable pathogenic mycobacteria in the peripheral blood mononuclear cells (PBMCs) of animals suffering from paratuberculosis. To adapt this method for the detection of M. bovis in blood, a new isothermal DNA amplification protocol using Recombinase Polymerase Amplification (RPA) was developed and was found to be able to detect M. bovis BCG within 48 h, with a limit of detection of approximately 10 cells per ml of blood for artificially inoculated blood samples. When blood samples (2 ml) from a Single Comparative Cervical Intradermal Tuberculin (SCCIT)- negative beef herd were tested, Mycobacterium tuberculosis complex (MTC) cells were not detected from any (45) of the blood samples. However when blood samples from SCCIT-positive animals were tested, viable MTC bacteria were detected in 66 % (27/41) of samples. Of these 41 animals sampled, 32 % (13) had visible lesions. In the visible lesion (VL) group, 85 % (11/13) had detectable levels of MTC whereas only 57 % (16/28) of animals which had no visible lesions (NVL) were found to have detectable mycobacteraemia. These results indicated that this simple, rapid method can be applied for the study of M. bovis infections. The frequency with which viable mycobacteria were detected in the peripheral blood of SCCIT-positive animals changes the paradigm of this disease.

  3. Tests of positive ion beams from a microwave ion source for AMS

    NASA Astrophysics Data System (ADS)

    Schneider, R. J.; von Reden, K. F.; Hayes, J. M.; Wills, J. S. C.; Kern, W. G. E.; Kim, S.-W.

    2000-10-01

    A test facility has been constructed to evaluate high-current positive ion beams from small gaseous samples for AMS applications. The major components include a compact permanent magnet microwave ion source built at the AECL Chalk River Laboratory and now on loan from the University of Toronto, and a double-focusing spectrometer magnet on loan from Argonne National Laboratory. Samples are introduced by means of a silica capillary injection system. Loop injection into a carrier gas provides a stable feed for the microwave driven plasma. The magnetic analysis system is utilized to isolate carbon ions derived from CO 2 samples from other products of the plasma discharge, including argon ions of the carrier gas. With a smaller discharge chamber, we hope to exceed a conversion efficiency of 14% for carbon ions produced per atom, which we reported at AMS-7. The next step will be to construct an efficient charge-exchange cell, to produce negative ions for injection into the WHOI recombinator injector.

  4. Rapid detection of in vitro antituberculous drug resistance among smear-positive respiratory samples using microcolony detection-based direct drug susceptibility testing method.

    PubMed

    Iftikhar, Irim; Irfan, Seema; Farooqi, Joveria; Azizullah, Zahida; Hasan, Rumina

    2017-01-01

    With the rise in multidrug-resistant tuberculosis, there is a search for newer techniques that will rapidly detect drug-resistant Mycobacterium tuberculosis. Although molecular techniques can detect resistance, culture is still considered gold standard, especially in resource-limited settings where quick, cheap, and easy techniques are needed. The aim of the study was to evaluate microcolony method thin layer agar (TLA) for quick detection of resistance against the first- and second-line antituberculous drugs in clinical isolates. This was a cross-sectional study performed at Aga Khan University Hospital. A total of 87 Z-N stain smear-positive pulmonary samples were received and indirect drug susceptibility test (ID-DST) was performed using Lowenstein-Jensen and mycobacteria growth indicator tube. Direct DST was performed using TLA on 7H10 agar. TLA was observed twice weekly under microscope for 4 weeks. Sensitivity, specificity, and accuracy were calculated for TLA using indirect susceptibility method as the gold standard. Level of agreement was calculated using Kappa score. TLA showed sensitivity of 89% and 95.2% for isoniazid and rifampicin, while for ethionamide, ofloxacin, and injectable aminoglycosides, it was 96.6%, 92.1%, and 100%, respectively. Specificity for the first-line drugs was >95% while second-line drugs ranged from 70% to 100%. Mean time to positivity was 10.2 days by TLA as compared to 43.1 days by ID-DST. TLA is a quick and reliable method in identifying resistance, especially in resource-limited settings. However, additional liquid culture can be set up as backup, especially in patients on therapy to avoid false negative results.

  5. 46 CFR 160.055-7 - Sampling, tests, and inspections.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Sampling, tests, and inspections. 160.055-7 Section 160.055-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND... and Child, for Merchant Vessels § 160.055-7 Sampling, tests, and inspections. (a) Production tests and...

  6. 46 CFR 160.055-7 - Sampling, tests, and inspections.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Sampling, tests, and inspections. 160.055-7 Section 160.055-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND... and Child, for Merchant Vessels § 160.055-7 Sampling, tests, and inspections. (a) Production tests and...

  7. 46 CFR 160.002-5 - Sampling, tests, and inspections.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Sampling, tests, and inspections. 160.002-5 Section 160.002-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND... Type), Models 3 and 5 § 160.002-5 Sampling, tests, and inspections. (a) Production tests and...

  8. 46 CFR 160.002-5 - Sampling, tests, and inspections.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Sampling, tests, and inspections. 160.002-5 Section 160.002-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND... Type), Models 3 and 5 § 160.002-5 Sampling, tests, and inspections. (a) Production tests and...

  9. Sample positioning apparatus

    DOEpatents

    Bell, Thomas H.; Johnson, Jr., Charles H.; Lane, Robert L.; Martin, Bradley E.; Tyree, William H.

    1976-01-06

    Apparatus for use in alpha particle counting with such as photomultiplier tubes, comprising a platform and linkage mechanism whereby samples are moved in linear manner toward and away from ends of the photomultiplier tubes.

  10. 46 CFR 160.005-5 - Sampling, tests, and inspections.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Sampling, tests, and inspections. 160.005-5 Section 160.005-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND... (Jacket Type), Models 52 and 56 § 160.005-5 Sampling, tests, and inspections. (a) Production tests and...

  11. 46 CFR 160.005-5 - Sampling, tests, and inspections.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Sampling, tests, and inspections. 160.005-5 Section 160.005-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND... (Jacket Type), Models 52 and 56 § 160.005-5 Sampling, tests, and inspections. (a) Production tests and...

  12. 43 CFR 3162.4-2 - Samples, tests, and surveys.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false Samples, tests, and surveys. 3162.4-2... for Operating Rights Owners and Operators § 3162.4-2 Samples, tests, and surveys. (a) During the... tests, run logs, and make other surveys reasonably necessary to determine the presence, quantity, and...

  13. 43 CFR 3162.4-2 - Samples, tests, and surveys.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false Samples, tests, and surveys. 3162.4-2... for Operating Rights Owners and Operators § 3162.4-2 Samples, tests, and surveys. (a) During the... tests, run logs, and make other surveys reasonably necessary to determine the presence, quantity, and...

  14. 43 CFR 3162.4-2 - Samples, tests, and surveys.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false Samples, tests, and surveys. 3162.4-2... for Operating Rights Owners and Operators § 3162.4-2 Samples, tests, and surveys. (a) During the... tests, run logs, and make other surveys reasonably necessary to determine the presence, quantity, and...

  15. [Characteristics of allergic conjunctivitis with positive skin prick test].

    PubMed

    Yang, S; Jiang, Y; Jin, Y M; Zhang, J Y; Li, Y

    2017-09-11

    Objective: To observe the clinical characteristics of allergic conjunctivitis, and the correlations with skin prick test results. Methods: A retrospective study. Forty patients with positive skin prick test result were included. Patients underwent an ophthalmologic examination to identify their primary presenting signs and symptoms. The allergy types were divided into 5 groups. All dates were analyzed for the dependence, normality and homogeneity of variance. Chi-square test, Mann-Whitney U test, Kruskal-Wallis H test and Spearman correlation analysis were performed accordingly. Results: Among 40 patients, 18(45.0%) had a clinical diagnosis of seasonal allergic conjunctivitis, 14(35.0%) had perennial allergic conjunctivitis, 5(12.5%) had vernal keratoconjunctivitis, and 2(5.0%) had atopic keratoconjunctivits, and 1(2.5%) had giant papillary conjunctivitis. There was no significant difference in the number of symptoms and signs score among different types of allergic conjunctivitis, the score of itching and hyperemia had a positive relationship with the number of positive allergens ( r =0.74, P< 0.05. r =0.96, P< 0.05). The primary symptoms and signs are itching and hyperemia; dust and pollens are the most common allergens. The more positive result of the test of the allergen, the more symptoms and signs encountered in terms of severity. Conclusion: Seasonal allergic conjunctivitis was the most prevalent disorder, the most important clinical characteristics of allergic conjunctivitis are itching and conjunctival congestion, the main allergens are dust and pollens, patients may be sensitive to multiple allergens. (Chin J Ophthalmol, 2017, 53: 689-693) .

  16. The Positive and Negative Consequences of Multiple-Choice Testing

    ERIC Educational Resources Information Center

    Roediger, Henry L.; Marsh, Elizabeth J.

    2005-01-01

    Multiple-choice tests are commonly used in educational settings but with unknown effects on students' knowledge. The authors examined the consequences of taking a multiple-choice test on a later general knowledge test in which students were warned not to guess. A large positive testing effect was obtained: Prior testing of facts aided final…

  17. Correcting Two-Sample "z" and "t" Tests for Correlation: An Alternative to One-Sample Tests on Difference Scores

    ERIC Educational Resources Information Center

    Zimmerman, Donald W.

    2012-01-01

    In order to circumvent the influence of correlation in paired-samples and repeated measures experimental designs, researchers typically perform a one-sample Student "t" test on difference scores. That procedure entails some loss of power, because it employs N - 1 degrees of freedom instead of the 2N - 2 degrees of freedom of the…

  18. High HIV Prevalence, Suboptimal HIV Testing, and Low Knowledge of HIV-Positive Serostatus Among Injection Drug Users in St. Petersburg, Russia

    PubMed Central

    Toussova, Olga V.; Verevochkin, Sergei V.; Barbour, Russell; Heimer, Robert; Kozlov, Andrei P.

    2011-01-01

    The purpose of this analysis was to estimate human immunodeficiency virus (HIV) prevalence and testing patterns among injection drug users (IDUs) in St. Petersburg, Russia. HIV prevalence among 387 IDUs in the sample was 50%. Correlates of HIV-positive serostatus included unemployment, recent unsafe injections, and history/current sexually transmitted infection. Seventy-six percent had been HIV tested, but only 22% of those who did not report HIV-positive serostatus had been tested in the past 12 months and received their test result. Correlates of this measure included recent doctor visit and having been in prison or jail among men. Among the 193 HIV-infected participants, 36% were aware of their HIV-positive serostatus. HIV prevalence is high and continuing to increase in this population. Adequate coverage of HIV testing has not been achieved, resulting in poor knowledge of positive serostatus. Efforts are needed to better understand motivating and deterring factors for HIV testing in this setting. PMID:18843531

  19. Swab2know: An HIV-Testing Strategy Using Oral Fluid Samples and Online Communication of Test Results for Men Who Have Sex With Men in Belgium.

    PubMed

    Platteau, Tom; Fransen, Katrien; Apers, Ludwig; Kenyon, Chris; Albers, Laura; Vermoesen, Tine; Loos, Jasna; Florence, Eric

    2015-09-01

    As HIV remains a public health concern, increased testing among those at risk for HIV acquisition is important. Men who have sex with men (MSM) are the most important group for targeted HIV testing in Europe. Several new strategies have been developed and implemented to increase HIV-testing uptake in this group, among them the Swab2know project. In this project, we aim to assess the acceptability and feasibility of outreach and online HIV testing using oral fluid samples as well as Web-based delivery of test results. Sample collection happened between December 2012 and April 2014 via outreach and online sampling among MSM. Test results were communicated through a secured website. HIV tests were executed in the laboratory. Each reactive sample needed to be confirmed using state-of-the-art confirmation procedures on a blood sample. Close follow-up of participants who did not pick up their results, and those with reactive results, was included in the protocol. Participants were asked to provide feedback on the methodology using a short survey. During 17 months, 1071 tests were conducted on samples collected from 898 men. Over half of the samples (553/1071, 51.63%) were collected during 23 outreach sessions. During an 8-month period, 430 samples out of 1071 (40.15%) were collected from online sampling. Additionally, 88 samples out of 1071 (8.22%) were collected by two partner organizations during face-to-face consultations with MSM and male sex workers. Results of 983 out of 1071 tests (91.78%) had been collected from the website. The pickup rate was higher among participants who ordered their kit online (421/430, 97.9%) compared to those participating during outreach activities (559/641, 87.2%; P<.001). MSM participating during outreach activities versus online participants were more likely to have never been tested before (17.3% vs 10.0%; P=.001) and reported more sexual partners in the 6 months prior to participation in the project (mean 7.18 vs 3.23; P<.001). A

  20. 10 CFR 707.7 - Random drug testing requirements and identification of testing designated positions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Random drug testing requirements and identification of... PROGRAMS AT DOE SITES Procedures § 707.7 Random drug testing requirements and identification of testing... evidence of the use of illegal drugs of employees in testing designated positions identified in this...

  1. 10 CFR 707.7 - Random drug testing requirements and identification of testing designated positions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Random drug testing requirements and identification of... PROGRAMS AT DOE SITES Procedures § 707.7 Random drug testing requirements and identification of testing... evidence of the use of illegal drugs of employees in testing designated positions identified in this...

  2. 10 CFR 707.7 - Random drug testing requirements and identification of testing designated positions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Random drug testing requirements and identification of... PROGRAMS AT DOE SITES Procedures § 707.7 Random drug testing requirements and identification of testing... evidence of the use of illegal drugs of employees in testing designated positions identified in this...

  3. 10 CFR 707.7 - Random drug testing requirements and identification of testing designated positions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Random drug testing requirements and identification of... PROGRAMS AT DOE SITES Procedures § 707.7 Random drug testing requirements and identification of testing... evidence of the use of illegal drugs of employees in testing designated positions identified in this...

  4. 10 CFR 707.7 - Random drug testing requirements and identification of testing designated positions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Random drug testing requirements and identification of... PROGRAMS AT DOE SITES Procedures § 707.7 Random drug testing requirements and identification of testing... evidence of the use of illegal drugs of employees in testing designated positions identified in this...

  5. 49 CFR 199.111 - Retention of samples and additional testing.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.111 Retention of samples and additional testing. (a... other than the unauthorized use of a prohibited drug, and if timely additional testing is requested by... 49 Transportation 3 2011-10-01 2011-10-01 false Retention of samples and additional testing. 199...

  6. 49 CFR 199.111 - Retention of samples and additional testing.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.111 Retention of samples and additional testing. (a... other than the unauthorized use of a prohibited drug, and if timely additional testing is requested by... 49 Transportation 3 2013-10-01 2013-10-01 false Retention of samples and additional testing. 199...

  7. 49 CFR 199.111 - Retention of samples and additional testing.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.111 Retention of samples and additional testing. (a... other than the unauthorized use of a prohibited drug, and if timely additional testing is requested by... 49 Transportation 3 2012-10-01 2012-10-01 false Retention of samples and additional testing. 199...

  8. 49 CFR 199.111 - Retention of samples and additional testing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.111 Retention of samples and additional testing. (a... other than the unauthorized use of a prohibited drug, and if timely additional testing is requested by... 49 Transportation 3 2010-10-01 2010-10-01 false Retention of samples and additional testing. 199...

  9. 49 CFR 199.111 - Retention of samples and additional testing.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.111 Retention of samples and additional testing. (a... other than the unauthorized use of a prohibited drug, and if timely additional testing is requested by... 49 Transportation 3 2014-10-01 2014-10-01 false Retention of samples and additional testing. 199...

  10. Advantages of analyzing postmortem brain samples in routine forensic drug screening-Case series of three non-natural deaths tested positive for lysergic acid diethylamide (LSD).

    PubMed

    Mardal, Marie; Johansen, Sys Stybe; Thomsen, Ragnar; Linnet, Kristian

    2017-09-01

    Three case reports are presented, including autopsy findings and toxicological screening results, which were tested positive for the potent hallucinogenic drug lysergic acid diethylamide (LSD). LSD and its main metabolites were quantified in brain tissue and femoral blood, and furthermore hematoma and urine when available. LSD, its main metabolite 2-oxo-3-hydroxy-LSD (oxo-HO-LSD), and iso-LSD were quantified in biological samples according to a previously published procedure involving liquid-liquid extraction and ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). LSD was measured in the brain tissue of all presented cases at a concentration level from 0.34-10.8μg/kg. The concentration level in the target organ was higher than in peripheral blood. Additional psychoactive compounds were quantified in blood and brain tissue, though all below toxic concentration levels. The cause of death in case 1 was collision-induced brain injury, while it was drowning in case 2 and 3 and thus not drug intoxication. However, the toxicological findings could help explain the decedent's inability to cope with brain injury or drowning incidents. The presented findings could help establish reference concentrations in brain samples and assist in interpretation of results from forensic drug screening in brain tissue. This is to the author's knowledge the first report of LSD, iso-LSD, and oxo-HO-LSD measured in brain tissue samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Cosmic veto gamma-spectrometry for Comprehensive Nuclear-Test-Ban Treaty samples

    NASA Astrophysics Data System (ADS)

    Burnett, J. L.; Davies, A. V.

    2014-05-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is supported by a global network of monitoring stations that perform high-resolution gamma-spectrometry on air filter samples for the identification of 85 radionuclides. At the UK CTBT Radionuclide Laboratory (GBL15), a novel cosmic veto gamma-spectrometer has been developed to improve the sensitivity of station measurements, providing a mean background reduction of 80.8% with mean MDA improvements of 45.6%. The CTBT laboratory requirement for a 140Ba MDA is achievable after 1.5 days counting compared to 5-7 days using conventional systems. The system consists of plastic scintillation plates that detect coincident cosmic-ray interactions within an HPGe gamma-spectrometer using the Canberra LynxTM multi-channel analyser. The detector is remotely configurable using a TCP/IP interface and requires no dedicated coincidence electronics. It would be especially useful in preventing false-positives at remote station locations (e.g. Halley, Antarctica) where sample transfer to certified laboratories is logistically difficult. The improved sensitivity has been demonstrated for a CTBT air filter sample collected after the Fukushima incident.

  12. Power of tests of normality for detecting contaminated normal samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thode, H.C. Jr.; Smith, L.A.; Finch, S.J.

    1981-01-01

    Seventeen tests of normality or goodness of fit were evaluated for power at detecting a contaminated normal sample. This study used 1000 replications each of samples of size 12, 17, 25, 33, 50, and 100 from six different contaminated normal distributions. The kurtosis test was the most powerful over all sample sizes and contaminations. The Hogg and weighted Kolmogorov-Smirnov tests were second. The Kolmogorov-Smirnov, chi-squared, Anderson-Darling, and Cramer-von-Mises tests had very low power at detecting contaminated normal random variables. Tables of the power of the tests and the power curves of certain tests are given.

  13. Recommended fine positioning test for the Development Test Flight (DTF-1) of the NASA Flight Telerobotic Servicer (FTS)

    NASA Technical Reports Server (NTRS)

    Dagalakis, N.; Wavering, A. J.; Spidaliere, P.

    1991-01-01

    Test procedures are proposed for the NASA DTF (Development Test Flight)-1 positioning tests of the FTS (Flight Telerobotic Servicer). The unique problems associated with the DTF-1 mission are discussed, standard robot performance tests and terminology are reviewed and a very detailed description of flight-like testing and analysis is presented. The major technical problem associated with DTF-1 is that only one position sensor can be used, which will be fixed at one location, with a working volume which is probably smaller than some of the robot errors to be measured. Radiation heating of the arm and the sensor could also cause distortions that would interfere with the test. Two robot performance testing committees have established standard testing procedures relevant to the DTF-1. Due to the technical problems associated with DTF-1, these procedures cannot be applied directly. These standard tests call for the use of several test positions at specific locations. Only one position, that of the position sensor, can be used by DTF-1. Off-line programming accuracy might be impossible to measure and in that case it will have to be replaced by forward kinetics accuracy.

  14. Design, test, and calibration of an electrostatic beam position monitor

    NASA Astrophysics Data System (ADS)

    Cohen-Solal, Maurice

    2010-03-01

    The low beta of proton or ion beams favors an electrostatic pickup to measure the transverse beam centroid position. Often papers on beam position monitors (BPM) are focused on a particular aspect of the problem; however, it is important to consider all various issues of a position measurement system. Based on our experience at the IPHI (high intensity injector proton) facility at CEA-Saclay, this paper will address all aspects to design, test, and calibrate a BPM for proton linear accelerators, while emphasizing the determination of the absolute beam position. We present details of the readout electronics, and describe the calibration of the BPM using a test station. For calculation and simulation of the electrical signals we developed a Mathematica script. The error analysis presented, on the basis of six BPMs installed in the high energy section of IPHI, demonstrates the expected accuracy of the position measurement. These studies also identify the parameters that could improve the performance of the beam position control. The experience from these developments is currently being used for the BPM design and test stand dedicated to the Spiral2 accelerator at Ganil-Caen which will deliver heavy ion beams.

  15. Outgassing tests on iras solar panel samples

    NASA Technical Reports Server (NTRS)

    Premat, G.; Zwaal, A.; Pennings, N. H.

    1980-01-01

    Several outgassing tests were carried out on representative solar panel samples in order to determine the extent of contamination that could be expected from this source. The materials for the construction of the solar panels were selected as a result of contamination obtained in micro volatile condensable materials tests.

  16. Potential Impact of Rapid Blood Culture Testing for Gram-Positive Bacteremia in Japan with the Verigene Gram-Positive Blood Culture Test

    PubMed Central

    Matsuda, Mari; Iguchi, Shigekazu; Mizutani, Tomonori; Hiramatsu, Keiichi; Tega-Ishii, Michiru; Sansaka, Kaori; Negishi, Kenta; Shimada, Kimie; Umemura, Jun; Notake, Shigeyuki; Yanagisawa, Hideji; Yabusaki, Reiko; Araoka, Hideki; Yoneyama, Akiko

    2017-01-01

    Background. Early detection of Gram-positive bacteremia and timely appropriate antimicrobial therapy are required for decreasing patient mortality. The purpose of our study was to evaluate the performance of the Verigene Gram-positive blood culture assay (BC-GP) in two special healthcare settings and determine the potential impact of rapid blood culture testing for Gram-positive bacteremia within the Japanese healthcare delivery system. Furthermore, the study included simulated blood cultures, which included a library of well-characterized methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant enterococci (VRE) isolates reflecting different geographical regions in Japan. Methods. A total 347 BC-GP assays were performed on clinical and simulated blood cultures. BC-GP results were compared to results obtained by reference methods for genus/species identification and detection of resistance genes using molecular and MALDI-TOF MS methodologies. Results. For identification and detection of resistance genes at two clinical sites and simulated blood cultures, overall concordance of BC-GP with reference methods was 327/347 (94%). The time for identification and antimicrobial resistance detection by BC-GP was significantly shorter compared to routine testing especially at the cardiology hospital, which does not offer clinical microbiology services on weekends and holidays. Conclusion. BC-GP generated accurate identification and detection of resistance markers compared with routine laboratory methods for Gram-positive organisms in specialized clinical settings providing more rapid results than current routine testing. PMID:28316631

  17. Evaluation of three sample preparation methods for the direct identification of bacteria in positive blood cultures by MALDI-TOF.

    PubMed

    Tanner, Hannah; Evans, Jason T; Gossain, Savita; Hussain, Abid

    2017-01-18

    Patient mortality is significantly reduced by rapid identification of bacteria from sterile sites. MALDI-TOF can identify bacteria directly from positive blood cultures and multiple sample preparation methods are available. We evaluated three sample preparation methods and two MALDI-TOF score cut-off values. Positive blood culture bottles with organisms present in Gram stains were prospectively analysed by MALDI-TOF. Three lysis reagents (Saponin, SDS, and SepsiTyper lysis bufer) were applied to each positive culture followed by centrifugation, washing and protein extraction steps. Methods were compared using the McNemar test and 16S rDNA sequencing was used to assess discordant results. In 144 monomicrobial cultures, using ≥2.000 as the cut-off value, species level identifications were obtained from 69/144 (48%) samples using Saponin, 86/144 (60%) using SDS, and 91/144 (63%) using SepsiTyper. The difference between SDS and SepsiTyper was not statistically significant (P = 0.228). Differences between Saponin and the other two reagents were significant (P < 0.01). Using ≥1.700 plus top three results matching as the cut-off value, species level identifications were obtained from 100/144 (69%) samples using Saponin, 103/144 (72%) using SDS, and 106/144 (74%) using SepsiTyper and there was no statistical difference between the methods. No true discordances between culture and direct MALDI-TOF identification were observed in monomicrobial cultures. In 32 polymicrobial cultures, MALDI-TOF identified one organism in 34-75% of samples depending on the method. This study demonstrates two inexpensive in-house detergent lysis methods are non-inferior to a commercial kit for analysis of positive blood cultures by direct MALDI-TOF in a clinical diagnostic microbiology laboratory.

  18. Diagnostic test accuracy and prevalence inferences based on joint and sequential testing with finite population sampling.

    PubMed

    Su, Chun-Lung; Gardner, Ian A; Johnson, Wesley O

    2004-07-30

    The two-test two-population model, originally formulated by Hui and Walter, for estimation of test accuracy and prevalence estimation assumes conditionally independent tests, constant accuracy across populations and binomial sampling. The binomial assumption is incorrect if all individuals in a population e.g. child-care centre, village in Africa, or a cattle herd are sampled or if the sample size is large relative to population size. In this paper, we develop statistical methods for evaluating diagnostic test accuracy and prevalence estimation based on finite sample data in the absence of a gold standard. Moreover, two tests are often applied simultaneously for the purpose of obtaining a 'joint' testing strategy that has either higher overall sensitivity or specificity than either of the two tests considered singly. Sequential versions of such strategies are often applied in order to reduce the cost of testing. We thus discuss joint (simultaneous and sequential) testing strategies and inference for them. Using the developed methods, we analyse two real and one simulated data sets, and we compare 'hypergeometric' and 'binomial-based' inferences. Our findings indicate that the posterior standard deviations for prevalence (but not sensitivity and specificity) based on finite population sampling tend to be smaller than their counterparts for infinite population sampling. Finally, we make recommendations about how small the sample size should be relative to the population size to warrant use of the binomial model for prevalence estimation. Copyright 2004 John Wiley & Sons, Ltd.

  19. Zika Virus Testing Considerations: Lessons Learned from the First 80 Real-Time Reverse Transcription-PCR-Positive Cases Diagnosed in New York State.

    PubMed

    St George, Kirsten; Sohi, Inderbir S; Dufort, Elizabeth M; Dean, Amy B; White, Jennifer L; Limberger, Ronald; Sommer, Jamie N; Ostrowski, Stephanie; Wong, Susan J; Backenson, P Bryon; Kuhles, Daniel; Blog, Debra; Taylor, Jill; Hutton, Brad; Zucker, Howard A

    2017-02-01

    The performance and interpretation of laboratory tests for Zika virus (ZKV) continue to be evaluated. Serology is cross-reactive, laborious, and frequently difficult to interpret, and serum was initially solely recommended for molecular diagnosis. ZKV testing was initiated in January 2016 in New York State for symptomatic patients, pregnant women, their infants, and patients with Guillain-Barré syndrome who had traveled to areas with ZKV transmission. Subsequently, eligibility was expanded to pregnant women with sexual partners with similar travel histories. Serum and urine collected within 4 weeks of symptom onset or within 6 weeks of travel were tested with real-time reverse transcription-PCR (RT-PCR) assays targeting the ZKV envelope and NS2B genes. In this review of lessons learned from the first 80 positive cases in NYS, ZKV RNA was detected in urine only in 50 patients, in serum only in 19 patients, and in both samples concurrently in 11 patients, with average viral loads in urine a log higher than those in serum. Among 93 positive samples from the 80 patients, 41 were positive on both gene assays, 52 were positive on the envelope only, and none were positive on the NS2B only. Of the 80 infected patients, test results for 74 (93%) would have defined their infection status as not detected or equivocal if the requirement for positive results from two assay targets (two-target-positive requirement) in the initial federal guidance to public health laboratories was enforced, if urine was not tested, or if the extended eligibility time for molecular testing was not implemented. These changes facilitated more extensive molecular diagnosis of ZKV, reducing reliance on time-consuming and potentially inconclusive serology. Copyright © 2017 American Society for Microbiology.

  20. Mass screening for Trypanosoma cruzi infections using the immunofluorescence, ELISA and haemagglutination tests on serum samples and on blood eluates from filter-paper.

    PubMed Central

    Zicker, F.; Smith, P. G.; Luquetti, A. O.; Oliveira, O. S.

    1990-01-01

    Methods used to diagnose Trypanosoma cruzi infection differ in their ability to discriminate between sera from infected and uninfected individuals. We compared the results of an immunofluorescence (IF) test, a haemagglutination (HA) test, and an enzyme-linked immunosorbent assay (ELISA) for the diagnosis of T. cruzi infections in a large population-based survey in central Brazil using blood eluates from filter-paper and venous blood samples. The sensitivities of the tests on eluates, compared with results on serum samples, were low: ELISA (78.1%), IF (69.2%) and HA (64.6%). The level of agreement between the tests on eluates was very poor, with the best co-positivity for IF and ELISA. Both the positive and negative predictive values of the three tests on eluates were similar (around 96%) to those for sera. Higher co-positivity values were obtained for the three tests on sera. The implications of these results are discussed in relation to blood screening, routine medical practice, sero-epidemiological surveys, and the follow-up of patients admitted to therapeutic trials. PMID:2119903

  1. Mass screening for Trypanosoma cruzi infections using the immunofluorescence, ELISA and haemagglutination tests on serum samples and on blood eluates from filter-paper.

    PubMed

    Zicker, F; Smith, P G; Luquetti, A O; Oliveira, O S

    1990-01-01

    Methods used to diagnose Trypanosoma cruzi infection differ in their ability to discriminate between sera from infected and uninfected individuals. We compared the results of an immunofluorescence (IF) test, a haemagglutination (HA) test, and an enzyme-linked immunosorbent assay (ELISA) for the diagnosis of T. cruzi infections in a large population-based survey in central Brazil using blood eluates from filter-paper and venous blood samples. The sensitivities of the tests on eluates, compared with results on serum samples, were low: ELISA (78.1%), IF (69.2%) and HA (64.6%). The level of agreement between the tests on eluates was very poor, with the best co-positivity for IF and ELISA. Both the positive and negative predictive values of the three tests on eluates were similar (around 96%) to those for sera. Higher co-positivity values were obtained for the three tests on sera. The implications of these results are discussed in relation to blood screening, routine medical practice, sero-epidemiological surveys, and the follow-up of patients admitted to therapeutic trials.

  2. 46 CFR 161.006-5 - Sampling, inspections and tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Sampling, inspections and tests. 161.006-5 Section 161.006-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND... Vessels § 161.006-5 Sampling, inspections and tests. (a) General. Motor lifeboat searchlights specified by...

  3. 46 CFR 161.006-5 - Sampling, inspections and tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Sampling, inspections and tests. 161.006-5 Section 161.006-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND... Vessels § 161.006-5 Sampling, inspections and tests. (a) General. Motor lifeboat searchlights specified by...

  4. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide residues...

  5. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide residues...

  6. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide residues...

  7. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide residues...

  8. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide residues...

  9. False-positive result when a diphenylcarbazide spot test is used on trivalent chromium-passivated zinc surfaces.

    PubMed

    Reveko, Valeriia; Lampert, Felix; Din, Rameez U; Thyssen, Jacob P; Møller, Per

    2018-05-01

    A colorimetric 1,5-diphenylcarbazide (DPC)-based spot test can be used to identify hexavalent chromium on various metallic and leather surfaces. DPC testing on trivalent chromium-passivated zinc surfaces has unexpectedly given positive results in some cases, apparently indicating the presence of hexavalent chromium; however, the presence of hexavalent chromium has never been confirmed with more sensitive and accurate test methods. To examine the presence of hexavalent chromium on trivalent chromium-passivated zinc surfaces with a DPC-based spot test. A colorimetric DPC spot test was used for the initial detection of hexavalent chromium on new and 1-year-aged trivalent chromium-passivated zinc surfaces. Then, X-ray photoelectron spectroscopy (XPS) was performed for all samples. The DPC spot test indicated the presence of hexavalent chromium in aged, but not new, trivalent chromium passivation on zinc; however, subsequent analysis by XPS could not confirm the presence of chromium in a hexavalent state. Unintended oxidation of DPC induced by atmospheric corrosion is suggested as a possible reason for the false-positive reaction of the DPC test on a trivalent chromium-passivated zinc surface. Further validation of the use of the DPC test for chromium-containing metallic surfaces is required. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. False-Positive Gen-Probe Direct Mycobacterium tuberculosis Amplification Test Results for Patients with Pulmonary M. kansasii and M. avium Infections

    PubMed Central

    Jorgensen, James H.; Salinas, Jesse R.; Paxson, Rosemary; Magnon, Karen; Patterson, Jan E.; Patterson, Thomas F.

    1999-01-01

    The Gen-Probe Amplified Mycobacterium Tuberculosis Direct (MTD) test has been approved for use in the United States for the rapid diagnosis of pulmonary tuberculosis in patients with acid-fast smear-positive sputum samples since 1996. Four patients infected with human immunodeficiency virus and one chronic pulmonary-disease patient seen in our institutions with abnormal chest radiographs and fluorochrome stain-positive sputa were evaluated for tuberculosis, including performance of the MTD test on expectorated sputum samples. Three of these five patients’ sputa were highly smear-positive (i.e., more than 100 bacilli per high-power field), while two patient’s sputa contained 1 to 10 bacilli per field. MTD results on sputum specimens from these patients ranged from 43,498 to 193,858 relative light units (RLU). Gen-Probe has defined values of at least 30,000 RLU as indicative of a positive test, i.e., the presence of Mycobacterium tuberculosis RNA. Four of the patients’ sputum cultures yielded growth of M. kansasii within 6 to 12 days, and the fifth produced growth of M. avium only. One patient’s culture contained both M. kansasii and M. avium, but none of the initial or follow-up cultures from these five patients revealed M. tuberculosis. However, subsequent cultures from three of the patients again revealed M. kansasii. During the period of this study, in which MTD tests were performed on smear-positive sputum specimens from 82 patients, four of seven patients with culture-proven M. kansasii pulmonary infections yielded one or more false-positive MTD tests. The MTD sensitivity observed in this study was 93.8%, and the specificity was 85.3%. Five cultures of M. kansasii (including three of these patients’ isolates and M. kansasii ATCC 12478), and cultures of several other species were examined at densities of 105 to 107 viable CFU/ml by the MTD test. All five isolates of M. kansasii and three of three isolates of M. simiae yielded false-positive test

  11. Contamination with HIV antibody may be responsible for false positive results in specimens tested on automated platforms running HIV 4th generation assays in a region of high HIV prevalence.

    PubMed

    Hardie, Diana Ruth; Korsman, Stephen N; Hsiao, Nei-Yuan; Morobadi, Molefi Daniel; Vawda, Sabeehah; Goedhals, Dominique

    2017-01-01

    In South Africa where the prevalence of HIV infection is very high, 4th generation HIV antibody/p24 antigen combo immunoassays are the tests of choice for laboratory based screening. Testing is usually performed in clinical pathology laboratories on automated analysers. To investigate the cause of false positive results on 4th generation HIV testing platforms in public sector laboratories, the performance of two automated platforms was compared in a clinical pathology setting, firstly on routine diagnostic specimens and secondly on known sero-negative samples. Firstly, 1181 routine diagnostic specimens were sequentially tested on Siemens and Roche automated 4th generation platforms. HIV viral load, western blot and follow up testing were used to determine the true status of inconclusive specimens. Subsequently, known HIV seronegative samples from a single donor were repeatedly tested on both platforms and an analyser was tested for surface contamination with HIV positive serum to identify how suspected specimen contamination could be occurring. Serial testing of diagnostic specimens yielded 163 weakly positive or discordant results. Only 3 of 163 were conclusively shown to indicate true HIV infection. Specimen contamination with HIV antibody was suspected, based on the following evidence: the proportion of positive specimens increased on repeated passage through the analysers; viral loads were low or undetectable and western blots negative or indeterminate on problem specimens; screen negative, 2nd test positive specimens tested positive when reanalysed on the screening assay; follow up specimens (where available) were negative. Similarly, an increasing number of known negative specimens became (repeatedly) sero-positive on serial passage through one of the analysers. Internal and external analyser surfaces were contaminated with HIV serum, evidence that sample splashes occur during testing. Due to the extreme sensitivity of these assays, contamination with minute

  12. A Performance Comparison on the Probability Plot Correlation Coefficient Test using Several Plotting Positions for GEV Distribution.

    NASA Astrophysics Data System (ADS)

    Ahn, Hyunjun; Jung, Younghun; Om, Ju-Seong; Heo, Jun-Haeng

    2014-05-01

    It is very important to select the probability distribution in Statistical hydrology. Goodness of fit test is a statistical method that selects an appropriate probability model for a given data. The probability plot correlation coefficient (PPCC) test as one of the goodness of fit tests was originally developed for normal distribution. Since then, this test has been widely applied to other probability models. The PPCC test is known as one of the best goodness of fit test because it shows higher rejection powers among them. In this study, we focus on the PPCC tests for the GEV distribution which is widely used in the world. For the GEV model, several plotting position formulas are suggested. However, the PPCC statistics are derived only for the plotting position formulas (Goel and De, In-na and Nguyen, and Kim et al.) in which the skewness coefficient (or shape parameter) are included. And then the regression equations are derived as a function of the shape parameter and sample size for a given significance level. In addition, the rejection powers of these formulas are compared using Monte-Carlo simulation. Keywords: Goodness-of-fit test, Probability plot correlation coefficient test, Plotting position, Monte-Carlo Simulation ACKNOWLEDGEMENTS This research was supported by a grant 'Establishing Active Disaster Management System of Flood Control Structures by using 3D BIM Technique' [NEMA-12-NH-57] from the Natural Hazard Mitigation Research Group, National Emergency Management Agency of Korea.

  13. The Dutch Brucella abortus monitoring programme for cattle: the impact of false-positive serological reactions and comparison of serological tests.

    PubMed

    Emmerzaal, A; de Wit, J J; Dijkstra, Th; Bakker, D; van Zijderveld, F G

    2002-02-01

    The Dutch national Brucella abortus eradication programme for cattle started in 1959. Sporadic cases occurred yearly until 1995; the last infected herd was culled in 1996. In August 1999 the Netherlands was declared officially free of bovine brucellosis by the European Union. Before 1999, the programme to monitor the official Brucella-free status of bovine herds was primarily based on periodical testing of dairy herds with the milk ring test (MRT) and serological testing of all animals older than 1 year of age from non-dairy herds, using the micro-agglutination test (MAT) as screening test. In addition, serum samples of cattle that aborted were tested with the MAT. The high number of false positive reactions in both tests and the serum agglutination test (SAT) and complement fixation test (CFT) used for confirmation seemed to result in unnecessary blockade of herds, subsequent testing and slaughter of animals. For this reason, a validation study was performed in which three indirect enzyme-linked immunosorbent assays (ELISAs), the CFT and the SAT were compared using a panel of sera from brucellosis-free cattle, sera from experimentally infected cattle, and sera from cattle experimentally infected with bacteria which are known to induce cross-reactive antibodies (Pasteurella, Salmonella, Yersinia, and Escherichia). Moreover, four ELISAs and the MRT were compared using a panel of 1000 bulk milk samples from Brucella-free herds and 12 milk samples from Brucella abortus- infected cattle. It is concluded that the ELISA obtained from ID-Lelystad is the most suitable test to monitor the brucelosis free status of herds because it gives rise to fewer false-positive reactions than the SAT.

  14. Optimum sample size allocation to minimize cost or maximize power for the two-sample trimmed mean test.

    PubMed

    Guo, Jiin-Huarng; Luh, Wei-Ming

    2009-05-01

    When planning a study, sample size determination is one of the most important tasks facing the researcher. The size will depend on the purpose of the study, the cost limitations, and the nature of the data. By specifying the standard deviation ratio and/or the sample size ratio, the present study considers the problem of heterogeneous variances and non-normality for Yuen's two-group test and develops sample size formulas to minimize the total cost or maximize the power of the test. For a given power, the sample size allocation ratio can be manipulated so that the proposed formulas can minimize the total cost, the total sample size, or the sum of total sample size and total cost. On the other hand, for a given total cost, the optimum sample size allocation ratio can maximize the statistical power of the test. After the sample size is determined, the present simulation applies Yuen's test to the sample generated, and then the procedure is validated in terms of Type I errors and power. Simulation results show that the proposed formulas can control Type I errors and achieve the desired power under the various conditions specified. Finally, the implications for determining sample sizes in experimental studies and future research are discussed.

  15. Notes on testing non-inferiority under the partial verification design with a confirmatory procedure limited to screen positives.

    PubMed

    Lui, Kung-Jong

    2012-05-01

    When a new test with fewer invasions or less expenses to administer than the traditional test is developed, we may be interested in testing whether the former is non-inferior to the latter with respect to test accuracy. We define non-inferiority via both the odds ratio (OR) of correctly identifying a case and the OR of correctly identifying a non-case between two tests under comparison. We focus our discussion on testing the non-inferiority of a new screening test to a traditional screening test when a confirmatory procedure is performed only on patients with screen positives. On the basis of well-established methods for paired-sample data, we derive an asymptotic test procedure and an exact test procedure with respect to the two ORs defined here. Using Monte Carlo simulation, we evaluate the performance of these test procedures in a variety of situations. We note that the test procedures proposed here can also be applicable if we are interested in testing non-inferiority with respect to the ratio of sensitivities and the ratio of specificities. We discuss interval estimation of these ORs and sample size calculation based on the asymptotic test procedure considered here. We use the data taken from a study of the prostate-specific-antigen (PSA) test and the digital rectal examination (DRE) test to illustrate the practical use of these test procedures, interval estimators and sample size calculation formula. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. 17 CFR Appendix B to Part 420 - Sample Large Position Report

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., and as collateral for financial derivatives and other securities transactions $ Total Memorandum 1... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Sample Large Position Report B Appendix B to Part 420 Commodity and Securities Exchanges DEPARTMENT OF THE TREASURY REGULATIONS UNDER...

  17. Does Performing Preplacement Workplace Hair Drug Testing Influence US Department of Transportation Random and Postaccident Urine Drug Test Positivity Rates?

    PubMed

    Price, James W

    Does performing pre-employment hair drug testing subsequently affect the prevalence of positive random and postaccident urine drug tests? This cross-sectional study was designed to evaluate the prevalence of positive postaccident and random workplace urine drug tests for companies that perform pre-employment hair and urine drug testing to companies that only perform pre-employment urine drug testing. Fisher exact test of independence indicated no significant difference between pre-employment hair drug testing and overall US Department of Transportation random and postaccident urine drug test positivity rates. The analysis failed to reject the null hypothesis, suggesting that pre-employment hair drug testing had no effect upon random and postaccident urine drug test positivity rates.

  18. Vertical jumping tests in volleyball: reliability, validity, and playing-position specifics.

    PubMed

    Sattler, Tine; Sekulic, Damir; Hadzic, Vedran; Uljevic, Ognjen; Dervisevic, Edvin

    2012-06-01

    Vertical jumping is known to be important in volleyball, and jumping performance tests are frequently studied for their reliability and validity. However, most studies concerning jumping in volleyball have dealt with standard rather than sport-specific jumping procedures and tests. The aims of this study, therefore, were (a) to determine the reliability and factorial validity of 2 volleyball-specific jumping tests, the block jump (BJ) test and the attack jump (AJ) test, relative to 2 frequently used and systematically validated jumping tests, the countermovement jump test and the squat jump test and (b) to establish volleyball position-specific differences in the jumping tests and simple anthropometric indices (body height [BH], body weight, and body mass index [BMI]). The BJ was performed from a defensive volleyball position, with the hands positioned in front of the chest. During an AJ, the players used a 2- to 3-step approach and performed a drop jump with an arm swing followed by a quick vertical jump. A total of 95 high-level volleyball players (all men) participated in this study. The reliability of the jumping tests ranged from 0.97 to 0.99 for Cronbach's alpha coefficients, from 0.93 to 0.97 for interitem correlation coefficients and from 2.1 to 2.8 for coefficients of variation. The highest reliability was found for the specific jumping tests. The factor analysis extracted one significant component, and all of the tests were highly intercorrelated. The analysis of variance with post hoc analysis showed significant differences between 5 playing positions in some of the jumping tests. In general, receivers had a greater jumping capacity, followed by libero players. The differences in jumping capacities should be emphasized vis-a-vis differences in the anthropometric measures of players, where middle hitters had higher BH and body weight, followed by opposite hitters and receivers, with no differences in the BMI between positions.

  19. Does the Position of Response Options in Multiple-Choice Tests Matter?

    ERIC Educational Resources Information Center

    Hohensinn, Christine; Baghaei, Purya

    2017-01-01

    In large scale multiple-choice (MC) tests alternate forms of a test may be developed to prevent cheating by changing the order of items or by changing the position of the response options. The assumption is that since the content of the test forms are the same the order of items or the positions of the response options do not have any effect on…

  20. Marine Bacteria Cause False-Positive Results in the Colilert-18 Rapid Identification Test for Escherichia coli in Florida Waters

    PubMed Central

    Pisciotta, John M.; Rath, Damon F.; Stanek, Paul A.; Flanery, D. Michael; Harwood, Valerie J.

    2002-01-01

    The Colilert-18 system for enumeration of total coliforms and Escherichia coli is approved by the U.S. Environmental Protection Agency for use in drinking water analysis and is also used by various agencies and research studies for enumeration of indicator organisms in fresh and saline waters. During monitoring of Pinellas County, Fla., marine waters, estimates of E. coli numbers (by Colilert-18) frequently exceeded fecal coliform counts (by membrane filtration) by 1 to 3 orders of magnitude. Samples from freshwater sites did not display similar discrepancies. Fecal coliforms, including E. coli, could be cultured from 100% of yellow fluorescent wells (denoting E. coli-positive results) inoculated with freshwater samples but could be cultured from only 17.1% of the “positive” wells inoculated with marine samples. Ortho-nitrophenyl-β-d-galactopyranoside (ONPG)-positive or 4-methylumbelliferyl-β-d-glucuronide (MUG)-positive noncoliform bacteria were readily cultured from Colilert-18 test wells inoculated with marine samples. Filtered cell-free seawater did not cause false positives. Coculture preparations of as few as 5 CFU of Vibrio cholerae (ONPG positive) and Providencia sp. (MUG positive) ml−1 inoculated into Colilert-18 caused false-positive E. coli results. Salinity conditions influenced coculture results, as the concentration of coculture inoculum required to cause false positives in most wells increased from about 5 CFU ml−1 in seawater diluted 1:10 with freshwater to ≈5,000 CFU ml−1 in seawater diluted 1:20 with freshwater. Estimated E. coli numbers in various marine water samples processed at the 1:10 dilution ranged from 10 to 7,270 CFU·100 ml−1, while E. coli numbers in the same samples processed at the 1:20 dilution did not exceed 40 CFU·100 ml−1. The lower estimates of E. coli numbers corresponded well with fecal coliform counts by membrane filtration. This study indicates that assessment of E. coli in subtropical marine waters by

  1. Sampling and position effects in the Electronically Steered Thinned Array Radiometer (ESTAR)

    NASA Technical Reports Server (NTRS)

    Katzberg, Stephen J.

    1993-01-01

    A simple engineering level model of the Electronically Steered Thinned Array Radiometer (ESTAR) is developed that allows an identification of the major effects of the sampling process involved with this technique. It is shown that the ESTAR approach is sensitive to aliasing and has a highly non-uniform sensitivity profile. It is further shown that the ESTAR approach is strongly sensitive to position displacements of the low-density sampling antenna elements.

  2. Urine sampling and collection system optimization and testing

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Geating, J. A.; Koesterer, M. G.

    1975-01-01

    A Urine Sampling and Collection System (USCS) engineering model was developed to provide for the automatic collection, volume sensing and sampling of urine from each micturition. The purpose of the engineering model was to demonstrate verification of the system concept. The objective of the optimization and testing program was to update the engineering model, to provide additional performance features and to conduct system testing to determine operational problems. Optimization tasks were defined as modifications to minimize system fluid residual and addition of thermoelectric cooling.

  3. Evaluation of genotype MTBDRplus VER 2.0 line probe assay for the detection of MDR-TB in smear positive and negative sputum samples.

    PubMed

    Meaza, Abyot; Kebede, Abebaw; Yaregal, Zelalem; Dagne, Zekarias; Moga, Shewki; Yenew, Bazezew; Diriba, Getu; Molalign, Helina; Tadesse, Mengistu; Adisse, Desalegn; Getahun, Muluwork; Desta, Kassu

    2017-04-17

    Multi drug resistant tuberculosis (MDR-TB) poses formidable challenges to TB control due to its complex diagnostic and treatment challenges and often associated with a high rate of mortality. Accurate and rapid detection of MDR-TB is critical for timely initiation of treatment. Line Probe Assay (LPA) is a qualitative in vitro diagnostic test based on DNA-STRIP technology for the identification of the M. tuberculosis complex and its resistance to rifampicin (RMP) and/or isoniazid (INH). Hain Lifescience, GmbH, Germany has improved the sensitivity of Genotype MTBDRplus VER 2.0 LPA for the detection of MDR-TB; with the possibility of applying the tool in smear negative sputum samples. A cross sectional study was conducted on 274 presumptive MDR-TB patients referred to the National TB Reference Laboratory (NTRL), Ethiopian Public Health Institute (EPHI) who submitted sputum samples for laboratory diagnosis of drug resistant-TB testing. Seventy-two smear and culture positive samples processed in smear positive direct LPA category and 197 smear negative sputum samples were processed for direct LPA. Among the smear negative samples 145 (73.6%) were culture negative and 26 (13.2%) were culture positive. All specimens were processed using NALC-NaOH method and ZN smear microscopy done from sediments. Genotype MTBDRplus VER 2.0 done from processed sputum sediments and the result was compared against the reference, BACTEC MGIT 960 culture and DST. Sensitivity, specificity, PPV and NPV of Genotype MTBDRplus VER 2.0 assay was determined and P-value <0.05 was considered as statistically significant. The sensitivity, specificity, PPV and NPV of Genotype MTBDRplus VER 2.0 LPA were 96.4, 100, 100 and 96.9%, respectively for the detection of MDR-TB from direct smear positive sputum samples. The sensitivity, specificity, PPV and NPV of Genotype MTBDR plus VER 2.0 LPA were 77.8, 97.2, 82.4 and 97.2%, respectively, for the detection of M. tuberculosis from direct smear negative sputum

  4. Report on Electrochemcial Corrosion Testing of 241-SY-102 Grab Samples from the 2012 Grab Sampling Campaign

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wyrwas, Richard B.; Lamothe, Margaret E.

    2013-05-30

    This report describes the results of the electrochemical testing performed on tank 241-SY-102 (SY-102) grab samples that were collected in support of corrosion mitigation. The objective of the work presented here was to determine corrosion resistance of tank SY-102 to the grab samples collected using electrochemical methods up to 50°C as well as to satisfy data quality objectives. Grab samples were collected at multiple elevations from Riser 003. The electrochemical corrosion testing was planned to consist of linear polarization resistance testing (LPR) and cyclic potentiodynamic polarization (CPP) testing at 50°C. The temperature would be lowered to 40 °C and themore » test repeated if the CPP curve indicated pitting corrosion at 50°C. Ifno pitting was indicated by the CPP curve, then a duplicate scan would be repeated at 50°C to confirm the first result. The testing would be complete if the duplicate CPP scan was consistent with the first. This report contains the CPP results of the testing of grab sample 2SY-12-03 and 2SY-12-03DUP composite sample tested under these conditions. There was no indication of pitting at 50°C, and the duplicate scan was in agreement with the first scan. Since no further testing was required, a third scan with a shorter rest time was performed and is present in this report.« less

  5. Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings.

    PubMed

    Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck

    2015-05-14

    Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false

  6. Herbalife hepatotoxicity: Evaluation of cases with positive reexposure tests.

    PubMed

    Teschke, Rolf; Frenzel, Christian; Schulze, Johannes; Schwarzenboeck, Alexander; Eickhoff, Axel

    2013-07-27

    To analyze the validity of applied test criteria and causality assessment methods in assumed Herbalife hepatotoxicity with positive reexposure tests. We searched the Medline database for suspected cases of Herbalife hepatotoxicity and retrieved 53 cases including eight cases with a positive unintentional reexposure and a high causality level for Herbalife. First, analysis of these eight cases focused on the data quality of the positive reexposure cases, requiring a baseline value of alanine aminotransferase (ALT) < 5 upper limit of normal (N) before reexposure, with N as the upper limit of normal, and a doubling of the ALT value at reexposure as compared to the ALT value at baseline prior to reexposure. Second, reported methods to assess causality in the eight cases were evaluated, and then the liver specific Council for International Organizations of Medical Sciences (CIOMS) scale validated for hepatotoxicity cases was used for quantitative causality reevaluation. This scale consists of various specific elements with scores provided through the respective case data, and the sum of the scores yields a causality grading for each individual case of initially suspected hepatotoxicity. Details of positive reexposure test conditions and their individual results were scattered in virtually all cases, since reexposures were unintentional and allowed only retrospective rather than prospective assessments. In 1/8 cases, criteria for a positive reexposure were fulfilled, whereas in the remaining cases the reexposure test was classified as negative (n = 1), or the data were considered as uninterpretable due to missing information to comply adequately with the criteria (n = 6). In virtually all assessed cases, liver unspecific causality assessment methods were applied rather than a liver specific method such as the CIOMS scale. Using this scale, causality gradings for Herbalife in these eight cases were probable (n = 1), unlikely (n = 4), and excluded (n = 3). Confounding

  7. Herbalife hepatotoxicity: Evaluation of cases with positive reexposure tests

    PubMed Central

    Teschke, Rolf; Frenzel, Christian; Schulze, Johannes; Schwarzenboeck, Alexander; Eickhoff, Axel

    2013-01-01

    AIM: To analyze the validity of applied test criteria and causality assessment methods in assumed Herbalife hepatotoxicity with positive reexposure tests. METHODS: We searched the Medline database for suspected cases of Herbalife hepatotoxicity and retrieved 53 cases including eight cases with a positive unintentional reexposure and a high causality level for Herbalife. First, analysis of these eight cases focused on the data quality of the positive reexposure cases, requiring a baseline value of alanine aminotransferase (ALT) < 5 upper limit of normal (N) before reexposure, with N as the upper limit of normal, and a doubling of the ALT value at reexposure as compared to the ALT value at baseline prior to reexposure. Second, reported methods to assess causality in the eight cases were evaluated, and then the liver specific Council for International Organizations of Medical Sciences (CIOMS) scale validated for hepatotoxicity cases was used for quantitative causality reevaluation. This scale consists of various specific elements with scores provided through the respective case data, and the sum of the scores yields a causality grading for each individual case of initially suspected hepatotoxicity. RESULTS: Details of positive reexposure test conditions and their individual results were scattered in virtually all cases, since reexposures were unintentional and allowed only retrospective rather than prospective assessments. In 1/8 cases, criteria for a positive reexposure were fulfilled, whereas in the remaining cases the reexposure test was classified as negative (n = 1), or the data were considered as uninterpretable due to missing information to comply adequately with the criteria (n = 6). In virtually all assessed cases, liver unspecific causality assessment methods were applied rather than a liver specific method such as the CIOMS scale. Using this scale, causality gradings for Herbalife in these eight cases were probable (n = 1), unlikely (n = 4), and excluded (n

  8. Implementation of Wi-Fi Signal Sampling on an Android Smartphone for Indoor Positioning Systems.

    PubMed

    Liu, Hung-Huan; Liu, Chun

    2017-12-21

    Collecting and maintaining radio fingerprint for wireless indoor positioning systems involves considerable time and labor. We have proposed the quick radio fingerprint collection (QRFC) algorithm which employed the built-in accelerometer of Android smartphones to implement step detection in order to assist in collecting radio fingerprints. In the present study, we divided the algorithm into moving sampling (MS) and stepped MS (SMS), and describe the implementation of both algorithms and their comparison. Technical details and common errors concerning the use of Android smartphones to collect Wi-Fi radio beacons were surveyed and discussed. The results of signal sampling experiments performed in a hallway measuring 54 m in length showed that in terms of the amount of time required to complete collection of access point (AP) signals, static sampling (SS; a traditional procedure for collecting Wi-Fi signals) took at least 2 h, whereas MS and SMS took approximately 150 and 300 s, respectively. Notably, AP signals obtained through MS and SMS were comparable to those obtained through SS in terms of the distribution of received signal strength indicator (RSSI) and positioning accuracy. Therefore, MS and SMS are recommended instead of SS as signal sampling procedures for indoor positioning algorithms.

  9. Validation of a modification to Performance-Tested Method 070601: Reveal Listeria Test for detection of Listeria spp. in selected foods and selected environmental samples.

    PubMed

    Alles, Susan; Peng, Linda X; Mozola, Mark A

    2009-01-01

    A modification to Performance-Tested Method (PTM) 070601, Reveal Listeria Test (Reveal), is described. The modified method uses a new media formulation, LESS enrichment broth, in single-step enrichment protocols for both foods and environmental sponge and swab samples. Food samples are enriched for 27-30 h at 30 degrees C and environmental samples for 24-48 h at 30 degrees C. Implementation of these abbreviated enrichment procedures allows test results to be obtained on a next-day basis. In testing of 14 food types in internal comparative studies with inoculated samples, there was a statistically significant difference in performance between the Reveal and reference culture [U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA/BAM) or U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS)] methods for only a single food in one trial (pasteurized crab meat) at the 27 h enrichment time point, with more positive results obtained with the FDA/BAM reference method. No foods showed statistically significant differences in method performance at the 30 h time point. Independent laboratory testing of 3 foods again produced a statistically significant difference in results for crab meat at the 27 h time point; otherwise results of the Reveal and reference methods were statistically equivalent. Overall, considering both internal and independent laboratory trials, sensitivity of the Reveal method relative to the reference culture procedures in testing of foods was 85.9% at 27 h and 97.1% at 30 h. Results from 5 environmental surfaces inoculated with various strains of Listeria spp. showed that the Reveal method was more productive than the reference USDA-FSIS culture procedure for 3 surfaces (stainless steel, plastic, and cast iron), whereas results were statistically equivalent to the reference method for the other 2 surfaces (ceramic tile and sealed concrete). An independent laboratory trial with ceramic tile inoculated with L

  10. Comparative evaluation of commercially available point-of-care heartworm antigen tests using well-characterized canine plasma samples.

    PubMed

    Starkey, Lindsay A; Bowles, Joy V; Payton, Mark E; Blagburn, Byron L

    2017-11-09

    Dirofilaria immitis is a worldwide parasite that is endemic in many parts of the United States. There are many commercial assays available for the detection of D. immitis antigen, one of which was modified and has reentered the market. Our objective was to compare the recently reintroduced Witness® Heartworm (HW) Antigen test Kit (Zoetis, Florham Park, NJ) and the SNAP® Heartworm RT (IDEXX Laboratories, Inc., Westbrook, ME) to the well-based ELISA DiroChek® Heartworm Antigen Test Kit (Zoetis, Florham Park, NJ). Canine plasma samples were either received at the Auburn Diagnostic Parasitology Laboratory from veterinarians submitting samples for additional heartworm testing (n = 100) from 2008 to 2016 or purchased from purpose-bred beagles (n = 50, presumed negative) in 2016. Samples were categorized as "positive," "borderline" or "negative" using our established spectrophotometric cutoff value with the DiroChek® assay when a sample was initially received and processed. Three commercially available heartworm antigen tests (DiroChek®, Witness® HW, and SNAP® RT) were utilized for simultaneous testing of the 150 samples in random order as per their package insert with the addition of spectrophotometric optical density (OD) readings of the DiroChek® assay. Any samples yielding discordant test results between assays were further evaluated by heat treatment of plasma and retesting. Chi-square tests for the equality of proportions were utilized for statistical analyses. Concordant results occurred in 140/150 (93.3%) samples. Discrepant results occurred in 10/150 samples tested (6.6%): 9/10 occurring in the borderline heartworm (HW) category and 1/10 occurring in the negative HW category. The sensitivity and specificity of each test compared to the DiroChek® read by spectrophotometer was similar to what has been reported previously (Witness®: sensitivity 97.0% [94.1-99.4%], specificity 96.4% [95.5-100.0%]; SNAP® RT: sensitivity 90.9% [78.0-100.0%], specificity

  11. Reliability and validity of the Positive Mental Health Questionnaire in a sample of Spanish university students.

    PubMed

    Roldán-Merino, J; Lluch-Canut, M T; Casas, I; Sanromà-Ortíz, M; Ferré-Grau, C; Sequeira, C; Falcó-Pegueroles, A; Soares, D; Puig-Llobet, M

    2017-03-01

    WHAT IS KNOWN ON THE SUBJECT?: In general, the current studies of positive mental health use questionnaires or parts thereof. However, while these questionnaires evaluate aspects of positive mental health, they fail to measure the construct itself. WHAT DOES THIS PAPER ADD TO EXISTING KNOWLEDGE?: The widespread use and the lack of specific questionnaires for evaluating the positive mental health construct justify the need to measure the robustness of the Positive Mental Health Questionnaire. Also six factors are proposed to measure positive mental health. WHAT ARE THE IMPLICATIONS FOR PRACTICE?: The availability of a good questionnaire to measure positive mental health in university students is useful not only to promote mental health but also to strengthen the curricula of future professionals. Introduction Nursing has a relevant role in managing mental health. It is important to identify and thereafter to enhance positive aspects of mental health among university nursing students. Aim The aim of the present study was to analyse the psychometric properties of the Positive Mental Health Questionnaire (PMHQ) in terms of reliability and validity using confirmatory factor analysis in a sample of university students. Method A cross-sectional study was carried out in a sample of 1091 students at 4 nursing schools in Catalonia, Spain. The reliability of the PMHQ was measured by means of Cronbach's alpha coefficient, and the test-retest stability was measured with the intraclass correlation coefficient (ICC). Confirmatory factor analysis was used to determine the validity of the factorial structure. Results Cronbach's alpha coefficient was satisfactory (>0.70) for four of the six subscales or dimensions and ranged from 0.54 to 0.79. ICC analysis was satisfactory for the six subscales or dimensions. The hypothesis was confirmed in the analysis of the correlations between subclasses and the overall scale, with the strongest correlations being found between the majority of

  12. HIV-positive MSM's knowledge of HPV and anal cancer self-sampling: A scoping review.

    PubMed

    Poon, M K L; Wong, J P H; Li, A T W; Manuba, M; Bisignano, A; Owino, M; Vahabi, M

    2018-02-01

    Human papillomavirus (hpv) infection is the cause of anal squamous cell cancer (ascc) in 80% of cases. Available research has also shown high prevalence of anal hpv infection among men who have sex with men (msm). However, hpv vaccination is low among msm in Canada. In light of this information, we conducted a scoping review with the aim of exploring (1) the knowledge of hpv and anal cancer among hiv-positive msm and (2) the acceptability of hpv and anal cancer self-sampling in this population. In conducting the review, we searched five electronic databases for peer-reviewed articles and abstracts published in English, between 2007 and 2017. A total of 803 articles were retrieved; after accounting for duplicates ( n= 40) and unmet criteria ( n= 754), a total of 794 articles were excluded. A final total of nine articles were used in this review. Results of this review show that hiv-positive msm have limited knowledge regarding the risks of anal cancer associated with hiv and hpv coinfection. Furthermore, there is limited research on hpv and anal cancer self-sampling in this population. However, the review of available studies suggested that hiv-positive msm were open to anal cancer self-sampling. It also identified potential barriers to self-sampling. In conclusion, we provide suggestions and future directions for policy-makers and educators to develop inclusive and accessible strategies to reach hiv-positive msm regarding anal cancer education and self-screening.

  13. Validation of Testing for a Multi-Disciplinary Technical Position.

    ERIC Educational Resources Information Center

    Sheppard, Valarie

    This paper describes a testing program that established job-related standards of performance and testing procedures for the technician position within a gas transportation company. New standards were being established in response to safety concerns stemming from investigations that identified training inadequacy as a cause of accidents. The job…

  14. Study of positive and negative feedback sensitivity in psychosis using the Wisconsin Card Sorting Test.

    PubMed

    Farreny, Aida; Del Rey-Mejías, Ángel; Escartin, Gemma; Usall, Judith; Tous, Núria; Haro, Josep Maria; Ochoa, Susana

    2016-07-01

    Schizophrenia involves marked motivational and learning deficits that may reflect abnormalities in reward processing. The purpose of this study was to examine positive and negative feedback sensitivity in schizophrenia using computational modeling derived from the Wisconsin Card Sorting Test (WCST). We also aimed to explore feedback sensitivity in a sample with bipolar disorder. Eighty-three individuals with schizophrenia and 27 with bipolar disorder were included. Demographic, clinical and cognitive outcomes, together with the WCST, were considered in both samples. Computational modeling was performed using the R syntax to calculate 3 parameters based on trial-by-trial execution on the WCST: reward sensitivity (R), punishment sensitivity (P), and choice consistency (D). The associations between outcome variables and the parameters were investigated. Positive and negative sensitivity showed deficits, but P parameter was clearly diminished in schizophrenia. Cognitive variables, age, and symptoms were associated with R, P, and D parameters in schizophrenia. The sample with bipolar disorder would show cognitive deficits and feedback abnormalities to a lesser extent than individuals with schizophrenia. Negative feedback sensitivity demonstrated greater deficit in both samples. Idiosyncratic cognitive requirements in the WCST might introduce confusion when supposing model-free reinforcement learning. Negative symptoms of schizophrenia were related to lower feedback sensitivity and less goal-directed patterns of choice. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Effects of positive results for Mycobacterium avium subsp paratuberculosis as determined by microbial culture of feces or antibody ELISA on results of caudal fold tuberculin test and interferon-gamma assay for tuberculosis in cattle.

    PubMed

    Dunn, John R; Kaneene, John B; Grooms, Daniel L; Bolin, Steven R; Bolin, Carole A; Bruning-Fann, Colleen S

    2005-02-01

    To determine whether cattle testing positive for Mycobacterium avium subsp paratuberculosis as determined by microbial culture of feces or antibody ELISA were more likely to have false-positive responses on the caudal fold tuberculin (CFT) test or interferon-gamma (IFN-gamma) assay for Mycobacterium bovis than cattle testing negative for M paratuberculosis. 1043 cattle from 10 herds in Michigan. Feces and blood samples for plasma were collected from cattle > or =24 months old on the day the CFT test was read. Fecal samples were submitted for microbial culture for M paratuberculosis. Plasma samples were tested for antibody against M paratuberculosis, and IFN-gamma after stimulation with purified protein derivative tuberculin from M bovis or M avium. Of 1043 cattle, 180 (17.3%) had positive CFT test results (suspects) and 8 (0.8%) had positive IFN-gamma assay results after stimulation with purified protein derivative tuberculin from M bovis. Forty-five (4.3%) and 115 (11.0%) cattle tested positive for M paratuberculosis as determined by microbial culture of feces and antibody ELISA, respectively. Cattle with positive responses for M paratuberculosis appeared to have an increased likelihood of false-positive results on the CFT test, although this association was not significant. No significant association was detected among cattle testing positive for M paratuberculosis as determined by microbial culture of feces and antibody ELISA and positive CFT test and IFN-gamma assay results for M bovis.

  16. Comparison of Antigen Detection and Nested PCR in CSF Samples of HIV Positive and Negative Patients with Suspected Cryptococcal Meningitis in a Tertiary Care Hospital.

    PubMed

    Kumari, Sunita; Verma, Rajesh Kumar; Singh, Dharmendra Prasad; Yadav, Ramakant

    2016-04-01

    The cases of cryptococcal meningitis and other forms of cryptococcosis have increased in recent time and the present scenario of the condition with significant morbidity and mortality is actually posing a serious threat to the community, so an early and prompt diagnosis is necessary to prevent serious complications and thus improving the overall disease outcome. Comparison of diagnostic efficacy of nested Polymerase Chain Reaction (PCR) with Latex Agglutination Test (LAT) in the Cerebro Spinal Fluid (CSF) samples of the cases of meningitis in HIV positive and negative cases. We have compared the diagnostic efficacy of Latex Agglutination Test (LAT) with nested Polymerase Chain Reaction (PCR) in 200 Cerebrospinal Fluid (CSF) samples, including 14 HIV positive also, in the cases of suspected cryptococcal meningitis. Nested PCR was done in all cases reporting positive by LAT and results were then compared with that of India ink and culture on Sabouraud Dextrose Agar (SDA), and the isolates were further identified by urease, nitrate and sugar assimilation tests. Of the 200 cases, including 14 HIV positive, LAT was positive in 46 cases while 154 were negative. Out of these 46 LAT positive cases, nested PCR was positive in 40 cases only, while culture and India ink was positive in 38 and 33 cases respectively. Majority of the cases, 30 (65.2%) were between age group 21-50 years, while 2 (4.3%) in 0-20, and 14 (30.4%) in 51-80 years age group. Although negative staining like India ink and nigrosin are most widely used techniques, but these suffer with subjective error. Rapid method like LAT is available but it always has the scope of false positive and negative results. In such cases nested PCR can help in establishing final diagnosis.

  17. Sampling theorem for geometric moment determination and its application to a laser beam position detector.

    PubMed

    Loce, R P; Jodoin, R E

    1990-09-10

    Using the tools of Fourier analysis, a sampling requirement is derived that assures that sufficient information is contained within the samples of a distribution to calculate accurately geometric moments of that distribution. The derivation follows the standard textbook derivation of the Whittaker-Shannon sampling theorem, which is used for reconstruction, but further insight leads to a coarser minimum sampling interval for moment determination. The need for fewer samples to determine moments agrees with intuition since less information should be required to determine a characteristic of a distribution compared with that required to construct the distribution. A formula for calculation of the moments from these samples is also derived. A numerical analysis is performed to quantify the accuracy of the calculated first moment for practical nonideal sampling conditions. The theory is applied to a high speed laser beam position detector, which uses the normalized first moment to measure raster line positional accuracy in a laser printer. The effects of the laser irradiance profile, sampling aperture, number of samples acquired, quantization, and noise are taken into account.

  18. Internet cognitive testing of large samples needed in genetic research.

    PubMed

    Haworth, Claire M A; Harlaar, Nicole; Kovas, Yulia; Davis, Oliver S P; Oliver, Bonamy R; Hayiou-Thomas, Marianna E; Frances, Jane; Busfield, Patricia; McMillan, Andrew; Dale, Philip S; Plomin, Robert

    2007-08-01

    Quantitative and molecular genetic research requires large samples to provide adequate statistical power, but it is expensive to test large samples in person, especially when the participants are widely distributed geographically. Increasing access to inexpensive and fast Internet connections makes it possible to test large samples efficiently and economically online. Reliability and validity of Internet testing for cognitive ability have not been previously reported; these issues are especially pertinent for testing children. We developed Internet versions of reading, language, mathematics and general cognitive ability tests and investigated their reliability and validity for 10- and 12-year-old children. We tested online more than 2500 pairs of 10-year-old twins and compared their scores to similar internet-based measures administered online to a subsample of the children when they were 12 years old (> 759 pairs). Within 3 months of the online testing at 12 years, we administered standard paper and pencil versions of the reading and mathematics tests in person to 30 children (15 pairs of twins). Scores on Internet-based measures at 10 and 12 years correlated .63 on average across the two years, suggesting substantial stability and high reliability. Correlations of about .80 between Internet measures and in-person testing suggest excellent validity. In addition, the comparison of the internet-based measures to ratings from teachers based on criteria from the UK National Curriculum suggests good concurrent validity for these tests. We conclude that Internet testing can be reliable and valid for collecting cognitive test data on large samples even for children as young as 10 years.

  19. GICHD mine dog testing project : soil sample results #5.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnett, James L.; Phelan, James M.; Archuleta, Luisa M.

    2004-01-01

    A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performance and seasonalmore » weather conditions. This report documents the analytical chemical methods and results from the fifth batch of soils received. This batch contained samples from Kharga, Afghanistan collected in June 2003.« less

  20. Sample features associated with success rates in population-based EGFR mutation testing.

    PubMed

    Shiau, Carolyn J; Babwah, Jesse P; da Cunha Santos, Gilda; Sykes, Jenna R; Boerner, Scott L; Geddie, William R; Leighl, Natasha B; Wei, Cuihong; Kamel-Reid, Suzanne; Hwang, David M; Tsao, Ming-Sound

    2014-07-01

    Epidermal growth factor receptor (EGFR) mutation testing has become critical in the treatment of patients with advanced non-small-cell lung cancer. This study involves a large cohort and epidemiologically unselected series of EGFR mutation testing for patients with nonsquamous non-small-cell lung cancer in a North American population to determine sample-related factors that influence success in clinical EGFR testing. Data from consecutive cases of Canadian province-wide testing at a centralized diagnostic laboratory for a 24-month period were reviewed. Samples were tested for exon-19 deletion and exon-21 L858R mutations using a validated polymerase chain reaction method with 1% to 5% detection sensitivity. From 2651 samples submitted, 2404 samples were tested with 2293 samples eligible for analysis (1780 histology and 513 cytology specimens). The overall test-failure rate was 5.4% with overall mutation rate of 20.6%. No significant differences in the failure rate, mutation rate, or mutation type were found between histology and cytology samples. Although tumor cellularity was significantly associated with test-success or mutation rates in histology and cytology specimens, respectively, mutations could be detected in all specimen types. Significant rates of EGFR mutation were detected in cases with thyroid transcription factor (TTF)-1-negative immunohistochemistry (6.7%) and mucinous component (9.0%). EGFR mutation testing should be attempted in any specimen, whether histologic or cytologic. Samples should not be excluded from testing based on TTF-1 status or histologic features. Pathologists should report the amount of available tumor for testing. However, suboptimal samples with a negative EGFR mutation result should be considered for repeat testing with an alternate sample.

  1. Workplace drug testing in Italy: findings about second-stage testing.

    PubMed

    Vignali, Claudia; Stramesi, Cristiana; Morini, Luca; San Bartolomeo, Paolo; Groppi, Angelo

    2015-03-01

    Workplace Drug Testing (WDT) in Italy includes two levels of monitoring: a first stage concerning drug testing on urine samples and a second involving both urine and hair analysis. The second stage is performed only on workers who tested positive at the first level. We analyzed urine and hair specimens from 120 workers undergoing second-level testing between 2009 and 2012. Eighty percent of them had tested positive for cannabinoids during the first level analysis, and 15.8% for cocaine. Both urine and hair samples were analyzed in order to find the following drugs of abuse: amphetamines, buprenorphine, cannabinoids, cocaine, ecstasy, methadone, and opiates. Urine analyses were performed by immunological screening (EMIT); urine confirmatory tests and hair analyses were performed by gas chromatography-mass spectrometry (GC-MS). As regards second-stage testing on urine samples, 71.2% of workers were always negative, whereas 23.9% tested positive at least once for cannabinoids and 2.5% for cocaine. Hair analyses produced surprising results: 61.9% of hair samples tested negative, only 6.2% tested positive for cannabinoids, whereas 28.8% tested positive for cocaine. These findings confirm that second-level surveillance of WDT, which includes hair analysis, is very effective because it highlights drug intake - sometimes heavy - that cannot be revealed only through urine analyses. The employees for whom drug addiction is proved can begin rehabilitation, while keeping their job. Eventually, our results confirmed the widespread and undeclared use of cocaine in Italy. Copyright © 2014 John Wiley & Sons, Ltd.

  2. 40 CFR 205.171-2 - Test exhaust system sample selection and preparation.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Test exhaust system sample selection... Systems § 205.171-2 Test exhaust system sample selection and preparation. (a)(1) Exhaust systems comprising the sample which are required to be tested under a test request in accordance with this subpart...

  3. Use of amplified Mycobacterium tuberculosis direct test in respiratory samples from HIV-infected patients in Brazil.

    PubMed

    Barreto, Leonardo Bruno Paz Ferreira; Lourenço, Maria Cristina da Silva; Rolla, Valéria Cavalcanti; Veloso, Valdiléia Gonçalves; Huf, Gisele

    2014-01-01

    To compare the accuracy of the amplified Mycobacterium tuberculosis direct (AMTD) test with reference methods for the laboratory diagnosis of tuberculosis in HIV-infected patients. This was a study of diagnostic accuracy comparing AMTD test results with those obtained by culture on Löwenstein-Jensen (LJ) medium and by the BACTEC Mycobacteria Growth Indicator Tube 960 (BACTEC MGIT 960) system in respiratory samples analyzed at the Bioassay and Bacteriology Laboratory of the Oswaldo Cruz Foundation Evandro Chagas Clinical Research Institute in the city of Rio de Janeiro, Brazil. We analyzed respiratory samples collected from 118 patients, of whom 88 (74.4%) were male. The mean age was 36.6 ± 10.6 years. Using the AMTD test, the BACTEC MGIT 960 system, and LJ culture, we identified M. tuberculosis complex in 31.0%, 29.7%, and 27.1% of the samples, respectively. In comparison with LJ culture, the AMTD test had a sensitivity, specificity, positive predictive value, and negative predictive value of 87.5%, 89.4%, 75.7%, and 95.0%, respectively, for LJ culture, whereas, in comparison with the BACTEC MGIT 960 system, it showed values of 88.6%, 92.4%, 83.8%, and 94.8%, respectively. The AMTD test showed good sensitivity and specificity in the population studied, enabling the laboratory detection of M. tuberculosis complex in paucibacillary respiratory specimens.

  4. Validation of the LacTek test applied to spiked extracts of tissue samples: determination of performance characteristics.

    PubMed

    Mitchell, J M; Yee, A J; McNab, W B; Griffiths, M W; McEwen, S A

    1999-01-01

    LacTek tests are competitive enzyme-linked immunosorbent assays intended for rapid detection of antimicrobial residues in bovine milk. In this study, the LacTek test protocol was modified for use with extracts of bovine tissue to detect beta-lactam, tetracycline, and sulfamethazine residues. Test performance characteristics--precision, accuracy, ruggedness, practicability, and analytical specificity and sensitivity--were investigated. Results suggest that LacTek tests can be easily adapted to detect antimicrobial residues in extracts of lean ground beef. However, positive samples may not contain residues at violative concentrations (i.e., Canadian maximum residue limits), and therefore, additional analysis would be required for final confirmation and quantitation (e.g., chromatography).

  5. Implementation of Wi-Fi Signal Sampling on an Android Smartphone for Indoor Positioning Systems

    PubMed Central

    Liu, Chun

    2017-01-01

    Collecting and maintaining radio fingerprint for wireless indoor positioning systems involves considerable time and labor. We have proposed the quick radio fingerprint collection (QRFC) algorithm which employed the built-in accelerometer of Android smartphones to implement step detection in order to assist in collecting radio fingerprints. In the present study, we divided the algorithm into moving sampling (MS) and stepped MS (SMS), and describe the implementation of both algorithms and their comparison. Technical details and common errors concerning the use of Android smartphones to collect Wi-Fi radio beacons were surveyed and discussed. The results of signal sampling experiments performed in a hallway measuring 54 m in length showed that in terms of the amount of time required to complete collection of access point (AP) signals, static sampling (SS; a traditional procedure for collecting Wi-Fi signals) took at least 2 h, whereas MS and SMS took approximately 150 and 300 s, respectively. Notably, AP signals obtained through MS and SMS were comparable to those obtained through SS in terms of the distribution of received signal strength indicator (RSSI) and positioning accuracy. Therefore, MS and SMS are recommended instead of SS as signal sampling procedures for indoor positioning algorithms. PMID:29267234

  6. Cross-validation of the Dot Counting Test in a large sample of credible and non-credible patients referred for neuropsychological testing.

    PubMed

    McCaul, Courtney; Boone, Kyle B; Ermshar, Annette; Cottingham, Maria; Victor, Tara L; Ziegler, Elizabeth; Zeller, Michelle A; Wright, Matthew

    2018-01-18

    To cross-validate the Dot Counting Test in a large neuropsychological sample. Dot Counting Test scores were compared in credible (n = 142) and non-credible (n = 335) neuropsychology referrals. Non-credible patients scored significantly higher than credible patients on all Dot Counting Test scores. While the original E-score cut-off of ≥17 achieved excellent specificity (96.5%), it was associated with mediocre sensitivity (52.8%). However, the cut-off could be substantially lowered to ≥13.80, while still maintaining adequate specificity (≥90%), and raising sensitivity to 70.0%. Examination of non-credible subgroups revealed that Dot Counting Test sensitivity in feigned mild traumatic brain injury (mTBI) was 55.8%, whereas sensitivity was 90.6% in patients with non-credible cognitive dysfunction in the context of claimed psychosis, and 81.0% in patients with non-credible cognitive performance in depression or severe TBI. Thus, the Dot Counting Test may have a particular role in detection of non-credible cognitive symptoms in claimed psychiatric disorders. Alternative to use of the E-score, failure on ≥1 cut-offs applied to individual Dot Counting Test scores (≥6.0″ for mean grouped dot counting time, ≥10.0″ for mean ungrouped dot counting time, and ≥4 errors), occurred in 11.3% of the credible sample, while nearly two-thirds (63.6%) of the non-credible sample failed one of more of these cut-offs. An E-score cut-off of 13.80, or failure on ≥1 individual score cut-offs, resulted in few false positive identifications in credible patients, and achieved high sensitivity (64.0-70.0%), and therefore appear appropriate for use in identifying neurocognitive performance invalidity.

  7. Testing of high-volume sampler inlets for the sampling of atmospheric radionuclides.

    PubMed

    Irshad, Hammad; Su, Wei-Chung; Cheng, Yung S; Medici, Fausto

    2006-09-01

    Sampling of air for radioactive particles is one of the most important techniques used to determine the nuclear debris from a nuclear weapon test in the Earth's atmosphere or those particles vented from underground or underwater tests. Massive-flow air samplers are used to sample air for any indication of radionuclides that are a signature of nuclear tests. The International Monitoring System of the Comprehensive Nuclear Test Ban Treaty Organization includes seismic, hydroacoustic, infrasound, and gaseous xenon isotopes sampling technologies, in addition to radionuclide sampling, to monitor for any violation of the treaty. Lovelace Respiratory Research Institute has developed a large wind tunnel to test the outdoor radionuclide samplers for the International Monitoring System. The inlets for these samplers are tested for their collection efficiencies for different particle sizes at various wind speeds. This paper describes the results from the testing of two radionuclide sampling units used in the International Monitoring System. The possible areas of depositional wall losses are identified and the losses in these areas are determined. Sampling inlet type 1 was tested at 2.2 m s wind speed for 5, 10, and 20-microm aerodynamic diameter particles. The global collection efficiency was about 87.6% for 10-microm particles for sampling inlet type 1. Sampling inlet type 2 was tested for three wind speeds at 0.56, 2.2, and 6.6 m s for 5, 10, and 20-microm aerodynamic diameter particles in two different configurations (sampling head lowered and raised). The global collection efficiencies for these configurations for 10-microm particles at 2.2 m s wind speed were 77.4% and 82.5%, respectively. The sampling flow rate was 600 m h for both sampling inlets.

  8. Positive concomitant test reactions to allergens in the standard patch test series.

    PubMed

    Landeck, Lilla; González, Ernesto; Baden, Lynn; Neumann, Konrad; Schalock, Peter

    2010-05-01

    Patch testing is performed to evaluate suspected allergic contact dermatitis. Common wisdom suggests that various allergens cross-react but only a few larger studies have published confirmations of this. The purpose of our study was to identify significant correlations between positive test reactions in a screening series. A total of 1235 patients undergoing patch testing to the Hermal standard series at the Massachusetts General Hospital, Contact Dermatitis Clinic between 1990 and 2006 were investigated. Two or more positive reactions were seen in 411 patients (33.3%). Sensitizations to eight pairs of allergens were found to have significant correlation (P

  9. Small sample mediation testing: misplaced confidence in bootstrapped confidence intervals.

    PubMed

    Koopman, Joel; Howe, Michael; Hollenbeck, John R; Sin, Hock-Peng

    2015-01-01

    Bootstrapping is an analytical tool commonly used in psychology to test the statistical significance of the indirect effect in mediation models. Bootstrapping proponents have particularly advocated for its use for samples of 20-80 cases. This advocacy has been heeded, especially in the Journal of Applied Psychology, as researchers are increasingly utilizing bootstrapping to test mediation with samples in this range. We discuss reasons to be concerned with this escalation, and in a simulation study focused specifically on this range of sample sizes, we demonstrate not only that bootstrapping has insufficient statistical power to provide a rigorous hypothesis test in most conditions but also that bootstrapping has a tendency to exhibit an inflated Type I error rate. We then extend our simulations to investigate an alternative empirical resampling method as well as a Bayesian approach and demonstrate that they exhibit comparable statistical power to bootstrapping in small samples without the associated inflated Type I error. Implications for researchers testing mediation hypotheses in small samples are presented. For researchers wishing to use these methods in their own research, we have provided R syntax in the online supplemental materials. (c) 2015 APA, all rights reserved.

  10. Testing theoretical relationships: factors influencing positive health practices (PHP) in Filipino college students.

    PubMed

    Ayres, Cynthia; Mahat, Ganga; Atkins, Robert

    2013-01-01

    To examine variables influencing the positive health practices (PHP) of Filipino college students to gain a better understanding of health practices in this ethnic/racial group. Cross-sectional study tested theoretical relationships postulated among (a) PHP, (b) social support (SS), (c) optimism, and (d) acculturation. A sample of Filipino college students (N = 226) aged 18 to 21 was obtained in June 2009. Participants completed 4 instruments. Statistical analyses were performed using SPSS 16.0. Positive correlations were found between PHP and SS (r = .39, p = .01) and optimism and PHP (r = .36, p = .01). No correlation was found between PHP and acculturation. Optimism and SS predicted performance of PHP (R (2) = .18, F[2, 221] = 24.927, p < .001). A difference was found in acculturation levels between participants who grew up in the United States (t[223] = 4.5, p < .001) and those who did not. Findings help health practitioners and educators to better understand the underlying factors that influence PHP in this population.

  11. Risk factors for visible lesions or positive laboratory tests in bovine tuberculosis reactor cattle in Northern Ireland.

    PubMed

    O'Hagan, M J H; Courcier, E A; Drewe, J A; Gordon, A W; McNair, J; Abernethy, D A

    2015-07-01

    An observational case-control study was conducted to investigate risk factors for confirmed bovine tuberculosis (bTB) infection in cattle reacting positively to the single intradermal comparative cervical test (SICCT) in Northern Ireland in the years 1998, 2002 and 2006. Macroscopic lesions were detected at slaughter (positive visible lesion (VL) status) in 43.0% of reactor cattle, whilst 45.3% of those sampled were confirmed as bTB positive due to the presence of lesions or positive histopathology/mycobacterial culture (positive bTB status). In 97.5% of the reactors, the VL status and bTB status were either both negative or both positive. Generalized linear mixed model analyses were conducted on data of 24,923 reactor cattle with the variables herd identifier, local veterinary office (DVO) and abattoir being used as random effects within all the models generated at univariable and multivariable level. The other variables within the dataset were used as fixed effects. Significant risk factors associated with VL status and bTB status at multivariable level (p<0.05) included age at death, breed, sex, test year, net increase in skin thickness at bovine tuberculin injection site, epidemiological status of skin test, total number of reactors at the disclosure test, mean herd size and prior response to the skin test. These risk factors are likely related to the time since infection, the strength of the challenge of infection and the susceptibility of the animal. These findings are important as the detection of visible lesions and the confirmation of bTB are an integral part of the overall bTB control programme in Northern Ireland and the veterinary meat inspection and hygiene programme. The visible lesion status and bTB status of an animal can affect the way in which bTB breakdowns are managed, since failure to detect visible lesions and recovery of Mycobacterium bovis can lead to a less stringent follow-up after other risk factors have been taken into account. Copyright

  12. GICHD mine dog testing project - soil sample results #4.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnett, James L.; Phelan, James M.; Archuleta, Luisa M.

    2003-08-01

    A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan and Bosnia containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performancemore » and seasonal weather conditions. This report documents the analytical chemical methods and results from the fourth batch of soils received. This batch contained samples from Kharga, Afghanistan collected in April 2003 and Sarajevo, Bosnia collected in May 2003.« less

  13. Operability test report for the in SITU vapor sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corbett, J.E., Westinghouse Hanford

    1996-05-31

    This report documents the successful completion of testing for the In Situ Vapor Sampling (ISVS) system. The report includes the test procedure (WHC-SD-WM-OTP-196, Rev OA), data sheets, exception resolutions, and a test report summary. This report conforms to the guidelines established in WHC-IP-1026, `Engineering Practice Guidelines,` Appendix L, `Operability Test Procedures and Reports.`

  14. Genetic Testing and Post-Testing Decision Making among BRCA-Positive Mutation Women: A Psychosocial Approach.

    PubMed

    Hesse-Biber, Sharlene; An, Chen

    2016-10-01

    Through an analysis of an online survey of women who tested positive for the BRCA genetic mutation for breast cancer, this research uses a social constructionist and feminist standpoint lens to understand the decision-making process that leads BRCA-positive women to choose genetic testing. Additionally, this research examines how they socially construct and understand their risk for developing breast cancer, as well as which treatment options they undergo post-testing. BRCA-positive women re-frame their statistical medical risk for developing cancer and their post-testing treatment choices through a broad psychosocial context of engagement that also includes their social networks. Important psychosocial factors drive women's medical decisions, such as individual feelings of guilt and vulnerability, and the degree of perceived social support. Women who felt guilty and fearful that they might pass the BRCA gene to their children were more likely to undergo risk reducing surgery. Women with at least one daughter and women without children were more inclined toward the risk reducing surgery compared to those with only sons. These psychosocial factors and social network engagements serve as a "nexus of decision making" that does not, for the most part, mirror the medical assessments of statistical odds for hereditary cancer development, nor the specific treatment protocols outlined by the medical establishment.

  15. Principles of Work Sample Testing. 2. Evaluation of Personnel Testing Programs

    DTIC Science & Technology

    1979-04-01

    i ARI TECHNICAL REPORT VE TR-79-A9 Principles of Work Sample Testing: II. Evaluation of Personnel Testing Programs by Robert M. Guion BOWLING GREEN ...STATE UNIVERSITY .Bowling Green , Ohio 43403 April 1979 Contract DAHC 19-77-C-0007 UK 0-. Prepared for C-, LA. U.S. ARMY RESEARCH INSTITUTE w for the...NAME AND ADDRESS V.PROGRAM ELEMENT. PROJECT. TASK Bowl iiq Green ’tate UniversityV Bowlilnq Green , Ohio 4 340i3 11. CONTROLLING OFFICE NAME AND ADDRESS

  16. 43 CFR 3593.1 - Core or test hole cores, samples, cuttings.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... (d) When drilling on lands with potential for encountering high pressure oil, gas or geothermal... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false Core or test hole cores, samples, cuttings...) EXPLORATION AND MINING OPERATIONS Bore Holes and Samples § 3593.1 Core or test hole cores, samples, cuttings...

  17. 43 CFR 3593.1 - Core or test hole cores, samples, cuttings.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... (d) When drilling on lands with potential for encountering high pressure oil, gas or geothermal... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false Core or test hole cores, samples, cuttings...) EXPLORATION AND MINING OPERATIONS Bore Holes and Samples § 3593.1 Core or test hole cores, samples, cuttings...

  18. 43 CFR 3593.1 - Core or test hole cores, samples, cuttings.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... (d) When drilling on lands with potential for encountering high pressure oil, gas or geothermal... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false Core or test hole cores, samples, cuttings...) EXPLORATION AND MINING OPERATIONS Bore Holes and Samples § 3593.1 Core or test hole cores, samples, cuttings...

  19. 43 CFR 3593.1 - Core or test hole cores, samples, cuttings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .... (d) When drilling on lands with potential for encountering high pressure oil, gas or geothermal... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false Core or test hole cores, samples, cuttings...) EXPLORATION AND MINING OPERATIONS Bore Holes and Samples § 3593.1 Core or test hole cores, samples, cuttings...

  20. 16 CFR § 1203.15 - Positional stability test (roll-off resistance).

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Positional stability test (roll-off... stability test (roll-off resistance). (a) Test equipment. (1) Headforms. The test headforms shall comply with the dimensions of the full chin ISO reference headforms sizes A, E, J, M, and O. (2) Test fixture...

  1. Prognostic Implications of Single-Sample Confirmatory Testing for Undiagnosed Diabetes: A Prospective Cohort Study.

    PubMed

    Selvin, Elizabeth; Wang, Dan; Matsushita, Kunihiro; Grams, Morgan E; Coresh, Josef

    2018-06-19

    Current clinical definitions of diabetes require repeated blood work to confirm elevated levels of glucose or hemoglobin A1c (HbA1c) to reduce the possibility of a false-positive diagnosis. Whether 2 different tests from a single blood sample provide adequate confirmation is uncertain. To examine the prognostic performance of a single-sample confirmatory definition of undiagnosed diabetes. Prospective cohort study. The ARIC (Atherosclerosis Risk in Communities) study. 13 346 ARIC participants (12 268 without diagnosed diabetes) with 25 years of follow-up for incident diabetes, cardiovascular outcomes, kidney disease, and mortality. Confirmed undiagnosed diabetes was defined as elevated levels of fasting glucose (≥7.0 mmol/L [≥126 mg/dL]) and HbA1c (≥6.5%) from a single blood sample. Among 12 268 participants without diagnosed diabetes, 978 had elevated levels of fasting glucose or HbA1c at baseline (1990 to 1992). Among these, 39% had both (confirmed undiagnosed diabetes), whereas 61% had only 1 elevated measure (unconfirmed undiagnosed diabetes). The confirmatory definition had moderate sensitivity (54.9%) but high specificity (98.1%) for identification of diabetes cases diagnosed during the first 5 years of follow-up, with specificity increasing to 99.6% by 15 years. The 15-year positive predictive value was 88.7% compared with 71.1% for unconfirmed cases. Confirmed undiagnosed diabetes was significantly associated with cardiovascular and kidney disease and mortality, with stronger associations than unconfirmed diabetes. Lack of repeated measurements of fasting glucose and HbA1c. A single-sample confirmatory definition of diabetes had a high positive predictive value for subsequent diagnosis and was strongly associated with clinical end points. Our results support the clinical utility of using a combination of elevated fasting glucose and HbA1c levels from a single blood sample to identify undiagnosed diabetes in the population. National Institute of

  2. Prevalence and risk factors for cats testing positive for feline immunodeficiency virus and feline leukaemia virus infection in cats entering an animal shelter in New Zealand.

    PubMed

    Gates, M C; Vigeant, S; Dale, A

    2017-11-01

    AIMS To estimate the prevalence of cats testing positive for antibodies to feline immunodeficiency virus (FIV) and feline leukaemia virus (FeLV) antigens in domestic cats entering a New Zealand animal shelter, based on a commercial point-of-care ELISA, to identify risk factors associated with cats testing positive, and to compare the results obtained from the ELISA with those obtained using PCR-based testing. METHOD A cross-sectional study was performed on 388 cats entering the Royal New Zealand Society for the Prevention of Cruelty to Animals animal shelter in Auckland, New Zealand between 7 February 2014 and 30 May 2014. Whole blood samples were collected from each cat and tested for FIV antibody and FeLV antigen using a commercial point-of-care ELISA. Information on the signalment and health status of the cat at the time of entry was also recorded. Blood and saliva samples from a subset of cats were tested for FIV and FeLV proviral DNA using a real-time PCR assay. RESULTS Of the 388 cats in the study sample, 146 (37.6%) had been relinquished by owners, 237 (62.4%) were strays, and 5 (1.3%) were of unknown origin. Overall, 53/388 (13.7%) cats tested positive for FIV antibodies and 4/388 (1.0%) were positive for FeLV antigen. Stray cats had a higher FIV seroprevalence than relinquished cats (42/237 (17.8%) vs. 11/146 (7.5%); p=0.008). Of 53 cats that were FIV-seropositive, 51 (96%) tested positive for FIV proviral DNA using PCR testing of blood. Of these 51 cats, 28 (55%) were positive by PCR testing of saliva. Of the four cats that were FeLV antigen-positive by ELISA, two (50%) were positive for FeLV proviral DNA by PCR testing of blood. The odds of a cat being seropositive for FIV were greater for intact compared to desexed cats (OR=3.3; 95% CI=1.6-7.4) and for male compared to female cats (OR=6.5; 95% CI=3.2-14.0). CONCLUSIONS AND CLINICAL RELEVANCE The seroprevalence for FIV was 14% among cats entering an animal shelter in Auckland, whereas the prevalence of

  3. Characteristics of children with positive tuberculin skin test.

    PubMed

    Hocaoğlu, Arzu Babayiğit; Erge, Duygu Olmez; Anal, Ozden; Makay, Balahan; Uzuner, Nevin; Karaman, Ozkan

    2011-01-01

    The aim of the study was to define the characteristics of children with latent tuberculosis diagnosed with positive tuberculin skin test (TST) and evaluate potential risk factors in children with positive TST. Children followed with the diagnosis of latent tuberculosis infection were included in the study retrospectively. Demographic characteristics of patients including history of atopy, respiratory infections, family history of tuberculosis and atopy, number of BCG vaccinations, findings of physical examination and laboratory data were extracted from patient's file. Eighty-one children (51 male, 30 female) who had positive TST were retrospectively evaluated in the study. Mean age of the patients was 8.00 ± 4.00 years. Only 13 (16%) of the children had contact with a case who had active tuberculosis. It was shown that the age of the patients, number of BCG scars and BCG vaccination significantly affected TST reaction size. TST size was not affected with time passed after last dose of BCG vaccination, family history of tuberculosis, presence of TST positive case in the family, exposure to cigarette smoke, number of household family members and presence of respiratory allergic disease. The patient's age, numbers of BCG vaccination and BCG scars significantly affect TST results in childhood. This may cause difficulty in diagnosing latent tuberculosis infection and in decision of initiating prophylactic treatment. The results of this study may show that recently developed, more accurate and convenient in vitro tests that they have higher costs and require sophisticated laboratory, can be used to diagnose latent tuberculosis.

  4. Profile of Clients Tested HIV Positive in a Voluntary Counseling and Testing Center of a District Hospital, Udupi, South Kannada

    PubMed Central

    A, Kumar; P, Kumar; M, Gupta; A, Kamath; A, Maheshwari; S, Singh

    2008-01-01

    Background: The growing menace created by the HIV/AIDS (human immunodeficiency virus/acquired immunodeficiency syndrome) has alarmed not only the public health officials but also the general community. The Voluntary Counseling and Testing Centre (VCTC) services have begun as a cost-effective intervention in reversing this epidemic. Objectives: 1. To study the sociodemographic characteristics of HIV-positive clients and their risk behaviors. 2. To elucidate the reasons for their visit to the VCTC and know the problems anticipated by the clients after revealing their HIV-positive status. Study Design: A cross-sectional record-based study. Materials and Methods: The study was conducted in August 2007 among clients who tested positive for HIV in the VCTC of a district hospital in Karnataka from January to July 2007. Results: Study included 249 individuals, of whom 64.7% were males, 88.7% (age, 15–49 years), married (72.7% males and 84.0% females) and literate (females 71.5% and males 85.7%). A high percentage of nonresponse regarding the pattern of risk behavior was noted among the subjects (males: 42.8% and females: 90.9%). Of the individuals who responded, 91 males (98.9%) and 6 females (75.0%) had multiple heterosexual sex partners, while 1 male had homosexual partner. The figures in females show that two (25%) of them had a history of blood transfusion. The reason for visiting the VCTC were cited as some form of illness (33.3%), confirmation of test results (32.9%), family members diagnosed as HIV positive (12.9%) and 11.6% were referred from Directly Observed Treatment Scheme (DOTS) center. More than three quarter of the sample population anticipated discrimination at the time of medical treatment. Conclusion: People have begun using VCTC services, which reflects a change in their attitude toward HIV. The study provides us a clue to formulate an effective approach to educate people as well as the health personnel who are thought of as one of the important

  5. A novel PMT test system based on waveform sampling

    NASA Astrophysics Data System (ADS)

    Yin, S.; Ma, L.; Ning, Z.; Qian, S.; Wang, Y.; Jiang, X.; Wang, Z.; Yu, B.; Gao, F.; Zhu, Y.; Wang, Z.

    2018-01-01

    Comparing with the traditional test system based on a QDC and TDC and scaler, a test system based on waveform sampling is constructed for signal sampling of the 8"R5912 and the 20"R12860 Hamamatsu PMT in different energy states from single to multiple photoelectrons. In order to achieve high throughput and to reduce the dead time in data processing, the data acquisition software based on LabVIEW is developed and runs with a parallel mechanism. The analysis algorithm is realized in LabVIEW and the spectra of charge, amplitude, signal width and rising time are analyzed offline. The results from Charge-to-Digital Converter, Time-to-Digital Converter and waveform sampling are discussed in detailed comparison.

  6. Internal Impingement of the Shoulder: A Risk of False Positive Test Outcomes in External Impingement Tests?

    PubMed

    Leschinger, Tim; Wallraff, Christopher; Müller, Dirk; Hackenbroch, Matthias; Bovenschulte, Henning; Siewe, Jan

    2017-01-01

    External impingement tests are considered as being particularly reliable for identifying subacromial and coracoid shoulder impingement mechanisms. The purpose of the present study was to evaluate if these tests are likely to provoke an internal shoulder impingement mechanism which, in cases of a pathologic condition, can lead to a positive test result. In 37 subjects, the mechanical contact between the glenoid rim and the rotator cuff (RC) was measured quantitatively and qualitatively in external impingement test positions using an open MRI system. Mechanical contact of the supraspinatus with the posterosuperior glenoid was present in 30 subjects in the Neer test. In the Hawkins test, the subscapularis was in contact with the anterosuperior glenoid in 33 subjects and the supraspinatus in 18. In the horizontal impingement test, anterosuperior contact of the supraspinatus with the glenoid was identified in 35 subjects. The Neer, Hawkins, and horizontal impingement tests are likely to provoke the mechanism of an internal shoulder impingement. A posterosuperior internal impingement mechanism is being provoked predominately in the Neer test. The Hawkins test narrows the distance between the insertions of the subscapularis and supraspinatus and the anterosuperior labrum, which leads to an anterosuperior impingement mechanism.

  7. Results of the long range position-determining system tests. [Field Army system

    NASA Technical Reports Server (NTRS)

    Rhode, F. W.

    1973-01-01

    The long range position-determining system (LRPDS) has been developed by the Corps of Engineers to provide the Field Army with a rapid and accurate positioning capability. The LRPDS consists of an airborne reference position set (RPS), up to 30 ground based positioning sets (PS), and a position computing central (PCC). The PCC calculates the position of each PS based on the range change information provided by each Set. The positions can be relayed back to the PS again via RPS. Each PS unit contains a double oven precise crystal oscillator. The RPS contains a Hewlett-Packard cesium beam standard. Frequency drifts and off-sets of the crystal oscillators are taken in account in the data reduction process. A field test program was initiated in November 1972. A total of 54 flights were made which included six flights for equipment testing and 48 flights utilizing the field test data reduction program. The four general types of PS layouts used were: short range; medium range; long range; tactical configuration. The overall RMS radial error of the unknown positions varied from about 2.3 meters for the short range to about 15 meters for the long range. The corresponding elevation RMS errors vary from about 12 meters to 37 meters.

  8. The Influence of Lying Body Position on Handwriting.

    PubMed

    Dziedzic, Tomasz

    2016-01-01

    Although the problem of handwriting variability due to lying body position has practical significance, particularly for last will cases, it has not been sufficiently studied. The presented experiment aimed to recognize how such posture may influence handwriting features. Samples of text and signatures were collected from 50 healthy individuals, aged 23-58, produced in three postures: typical sitting position (SP) and two different lying positions (LP1 & LP2). Using the SP sample of each individual as a specimen, eleven characteristics in LP1 and LP2 samples were evaluated as similar or different. Nine other features were measured with a specialized software, and their conformity was tested with Student's t-test. Although none of the characteristics differed significantly in most cases, variation occurred in pen pressure, margins, baselines, and heights of letters. Additionally, a series of blind tests revealed that lying position of the individuals did not hinder the possibility to identify their writings. © 2015 American Academy of Forensic Sciences.

  9. Detection of epidermal growth factor receptor gene T790M mutation in cytology samples using the cobas® EGFR mutation test.

    PubMed

    Satouchi, Miyako; Tanaka, Hiroshi; Yoshioka, Hiroshige; Shimokawaji, Tadasuke; Mizuno, Keiko; Takeda, Koji; Yoshino, Ichiro; Seto, Takashi; Kurata, Takayasu; Tashiro, Naoki; Hagiwara, Koichi

    2017-09-01

    Detection of epidermal growth factor receptor (EGFR) gene mutations is essential in deciding therapeutic strategy in non-small cell lung cancer (NSCLC) patients at initial diagnosis. Moreover, in EGFR mutation-positive (EGFRm) NSCLC patients, re-biopsy at disease progression to clarify resistance mechanisms is also important. However, collecting histology samples is often difficult because of inaccessibility and invasiveness. In some cases, only cytology samples can be collected, and studies have reported that cytology samples are appropriate for EGFR gene mutation testing. The cobas ® EGFR Mutation Test (Roche Molecular Systems Inc., Branchburg, New Jersey, USA) is approved as a companion diagnostic for osimertinib, a third-generation EGFR-tyrosine kinase inhibitor approved in Japan. However, it is not clear whether the EGFR T790M mutation can be detected in cytology samples using this test. The primary objective of this study was to assess concordance of EGFR T790M gene mutation detection between histology and matched cytology samples using the cobas ® EGFR Mutation Test. We conducted a multicenter, observational study in Japan. Overall, 41 EGFRm NSCLC patients who had both histology and cytology samples collected at the same time at re-biopsy and with the results of EGFR mutation test using histology samples were enrolled. The EGFR mutation status of both sample types was tested using the cobas ® EGFR Mutation Test and the concordance rates were calculated. The EGFR T790M mutation detection rate in histology and cytology samples was 42.5% and 37.5%, respectively. The overall percent agreement between the histology and cytology samples was 91.7%. These data demonstrate that the cobas ® EGFR Mutation Test can detect the EGFR T790M mutation in both cytology and histology samples. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  10. Liquid Microjunction Surface Sampling Probe Fluid Dynamics: Computational and Experimental Analysis of Coaxial Intercapillary Positioning Effects on Sample Manipulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ElNaggar, Mariam S; Barbier, Charlotte N; Van Berkel, Gary J

    A coaxial geometry liquid microjunction surface sampling probe (LMJ-SSP) enables direct extraction of analytes from surfaces for subsequent analysis by techniques like mass spectrometry. Solution dynamics at the probe-to-sample surface interface in the LMJ-SSP has been suspected to influence sampling efficiency and dispersion but has not been rigorously investigated. The effect on flow dynamics and analyte transport to the mass spectrometer caused by coaxial retraction of the inner and outer capillaries from each other and the surface during sampling with a LMJ-SSP was investigated using computational fluid dynamics and experimentation. A transparent LMJ-SSP was constructed to provide the means formore » visual observation of the dynamics of the surface sampling process. Visual observation, computational fluid dynamics (CFD) analysis, and experimental results revealed that inner capillary axial retraction from the flush position relative to the outer capillary transitioned the probe from a continuous sampling and injection mode through an intermediate regime to sample plug formationmode caused by eddy currents at the sampling end of the probe. The potential for analytical implementation of these newly discovered probe operational modes is discussed.« less

  11. Commutability of food microbiology proficiency testing samples.

    PubMed

    Abdelmassih, M; Polet, M; Goffaux, M-J; Planchon, V; Dierick, K; Mahillon, J

    2014-03-01

    Food microbiology proficiency testing (PT) is a useful tool to assess the analytical performances among laboratories. PT items should be close to routine samples to accurately evaluate the acceptability of the methods. However, most PT providers distribute exclusively artificial samples such as reference materials or irradiated foods. This raises the issue of the suitability of these samples because the equivalence-or 'commutability'-between results obtained on artificial vs. authentic food samples has not been demonstrated. In the clinical field, the use of noncommutable PT samples has led to erroneous evaluation of the performances when different analytical methods were used. This study aimed to provide a first assessment of the commutability of samples distributed in food microbiology PT. REQUASUD and IPH organized 13 food microbiology PTs including 10-28 participants. Three types of PT items were used: genuine food samples, sterile food samples and reference materials. The commutability of the artificial samples (reference material or sterile samples) was assessed by plotting the distribution of the results on natural and artificial PT samples. This comparison highlighted matrix-correlated issues when nonfood matrices, such as reference materials, were used. Artificially inoculated food samples, on the other hand, raised only isolated commutability issues. In the organization of a PT-scheme, authentic or artificially inoculated food samples are necessary to accurately evaluate the analytical performances. Reference materials, used as PT items because of their convenience, may present commutability issues leading to inaccurate penalizing conclusions for methods that would have provided accurate results on food samples. For the first time, the commutability of food microbiology PT samples was investigated. The nature of the samples provided by the organizer turned out to be an important factor because matrix effects can impact on the analytical results. © 2013

  12. Tube and column agglutination technology for autocontrol testing.

    PubMed

    Courtney, J E; Vincent, J L; Indrikovs, A J

    2001-01-01

    The incidence of positive autocontrol test results with column agglutination technology is a concern. This study investigates the incidence and significance of positive autocontrols in the ID Micro Typing System (gel) and the Gamma ReACT (ReACT). The study encompassed a total of 1021 randomly selected samples from patients and 95 samples from donors collected during 1 month. The autocontrol testing was carried out according to the manufacturer's instructions for the column agglutination tests. The tube method was carried out using low-ionic-strength solution (LISS). The direct antiglobulin test (DAT) was performed using the tube method, and further investigated with elution studies if warranted. Seventy-nine patient's samples (7.74%) had a positive autocontrol: the gel test, 72 (91.13%); ReACT, 21 (26.58%); and the tube method, 27 (34.18%). Of the 79 positive autocontrols, 44 samples had a negative DAT. Of the samples with positive DAT results, only one possessed a clinically significant antibody, anti-D. Moreover, the same sample also tested positive in all three methods. Column agglutination techniques have increased sensitivity for a positive autocontrol beyond the conventional tube method. However, ReACT and gel tests differ significantly in their frequency of positives. Investigation of the significance of a positive autocontrol in column agglutination technology when the conventional tube method is also positive is suggested.

  13. Positive train control desense mitigation test : research phase 1.

    DOT National Transportation Integrated Search

    2016-05-01

    Final report for Positive Train Control (PTC) Desense Mitigation Test Research project includes description of Northeast Corridor (NEC) PTC deployments, PTC radio desense scenarios, PTC radio desense mitigation approaches, PTC radio desense mitigatio...

  14. HIV-positive MSM’s knowledge of HPV and anal cancer self-sampling: A scoping review

    PubMed Central

    Poon, M.K.L.; Wong, J.P.H.; Li, A.T.W.; Manuba, M.; Bisignano, A.; Owino, M.; Vahabi, M.

    2018-01-01

    Human papillomavirus (hpv) infection is the cause of anal squamous cell cancer (ascc) in 80% of cases. Available research has also shown high prevalence of anal hpv infection among men who have sex with men (msm). However, hpv vaccination is low among msm in Canada. In light of this information, we conducted a scoping review with the aim of exploring (1) the knowledge of hpv and anal cancer among hiv-positive msm and (2) the acceptability of hpv and anal cancer self-sampling in this population. In conducting the review, we searched five electronic databases for peer-reviewed articles and abstracts published in English, between 2007 and 2017. A total of 803 articles were retrieved; after accounting for duplicates (n=40) and unmet criteria (n=754), a total of 794 articles were excluded. A final total of nine articles were used in this review. Results of this review show that hiv-positive msm have limited knowledge regarding the risks of anal cancer associated with hiv and hpv coinfection. Furthermore, there is limited research on hpv and anal cancer self-sampling in this population. However, the review of available studies suggested that hiv-positive msm were open to anal cancer self-sampling. It also identified potential barriers to self-sampling. In conclusion, we provide suggestions and future directions for policy-makers and educators to develop inclusive and accessible strategies to reach hiv-positive msm regarding anal cancer education and self-screening. PMID:29507499

  15. Field assessment of dried Plasmodium falciparum samples for malaria rapid diagnostic test quality control and proficiency testing in Ethiopia.

    PubMed

    Tamiru, Afework; Boulanger, Lucy; Chang, Michelle A; Malone, Joseph L; Aidoo, Michael

    2015-01-21

    Rapid diagnostic tests (RDTs) are now widely used for laboratory confirmation of suspected malaria cases to comply with the World Health Organization recommendation for universal testing before treatment. However, many malaria programmes lack quality control (QC) processes to assess RDT use under field conditions. Prior research showed the feasibility of using the dried tube specimen (DTS) method for preserving Plasmodium falciparum parasites for use as QC samples for RDTs. This study focused on the use of DTS for RDT QC and proficiency testing under field conditions. DTS were prepared using cultured P. falciparum at densities of 500 and 1,000 parasites/μL; 50 μL aliquots of these along with parasite negative human blood controls (0 parasites/μL) were air-dried in specimen tubes and reactivity verified after rehydration. The DTS were used in a field study in the Oromia Region of Ethiopia. Replicate DTS samples containing 0, 500 and 1,000 parasites/μL were stored at 4°C at a reference laboratory and at ambient temperatures at two nearby health facilities. At weeks 0, 4, 8, 12, 16, 20, and 24, the DTS were rehydrated and tested on RDTs stored under manufacturer-recommended temperatures at the RL and on RDTs stored under site-specific conditions at the two health facilities. Reactivity of DTS stored at 4°C at the reference laboratory on RDTs stored at the reference laboratory was considered the gold standard for assessing DTS stability. A proficiency-testing panel consisting of one negative and three positive samples, monitored with a checklist was administered at weeks 12 and 24. At all the seven time points, DTS stored at both the reference laboratory and health facility were reactive on RDTs stored under the recommended temperature and under field conditions, and the DTS without malaria parasites were negative. At the reference laboratory and one health facility, a 500 parasites/μL DTS from the proficiency panel was falsely reported as negative at week 24

  16. Upper Limb Neural Tension and Seated Slump Tests: The False Positive Rate among Healthy Young Adults without Cervical or Lumbar Symptoms.

    PubMed

    Davis, D Scott; Anderson, Ila Beth; Carson, Mary Grace; Elkins, Caroline L; Stuckey, Lindsey B

    2008-01-01

    This study examined the false positive rate of the upper limb neural tension test (ULNTT) and seated slump test (SST) among healthy young adults with no history of cervical, lumbar, or peripheral symptoms. Eighty-four subjects (27 men and 57 women) with a mean age of 22.9 years participated in the investigation. All participants completed a screening questionnaire designed to exclude subjects with a history of cervical or lumbar spine pain or injury, or upper or lower extremity neurological symptoms. The ULNTT and the SST were performed on the left upper and lower extremity of each participant. Of the 84 participants tested, 73 (86.9%) were found to have a positive ULNTT at some point in the available range of elbow extension. Twenty-eight (33.3%) of the 84 subjects had a positive SST at some point in the available range of knee extension. The mean knee extension angle for those subjects with a positive SST was 15.1 degrees with a 95% confidence interval (CI) of 12.3 and 19.7 degrees . The mean elbow extension angle for those with a positive ULNTT was 49.4 degrees with a 95% CI of 44.8 and 54.0 degrees . The number of positive tests for both the ULNTT and the SST was found to be high in this sample of asymptomatic healthy young adults. Based on the results of this investigation, the authors suggest that the current criteria for determining a positive test for both the ULNTT and the SST should be examined using the proposed range of motion cut-off scores.

  17. 16 CFR 1203.15 - Positional stability test (roll-off resistance).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... any slack. (3) Suspend the dynamic impact system from the helmet by positioning the flexible strap... positions. (3) Dynamic impact apparatus. A dynamic impact apparatus shall be used to apply a shock load to a helmet secured to the test headform. The dynamic impact apparatus shall allow a 4-kg (8.8-lb) drop weight...

  18. Evaluation of human papillomavirus detection by Abbott m2000 system on samples collected by FTA Elute™ Card in a Chinese HIV-1 positive population.

    PubMed

    Qin, Yu; Zhang, Hongyun; Marlowe, Natalia; Fei, Mandong; Yu, Judy; Lei, Xiaoqin; Yu, Lulu; Zhang, Jia; Cao, Di; Ma, Li; Chen, Wen

    2016-12-01

    HIV+/AIDS women have an increased risk of developing into CIN and cervical cancer compared to the general population. Limited medical resource and the lack of AIDS relevant knowledge impair the coverage and efficiency of cervical cancer screening. To compare the clinical performance of self-collected dry storage medium (FTA Elute card) and physician-collected PreservCyt medium in detection of high risk human papillomavirus (HR HPV) among HIV-1 positive population. Three hundred HIV-1 positive women (aged 25-65) were recruited from Yunnan infectious hospital. Two cervicovaginal samples were collected from each participant: one was collected by the women themselves and applied on a FTA Elute card; the other one was collected by a physician and stored in PreservCyt solution. All the samples were tested for 14 HR HPV using Abbott RealTime High Risk HPV assay. Biopsies were taken for histological diagnosis if any abnormal impression was noticed under colposcopy. 291 (97.0%) of participants were eligible for this study. 101 (34.70%) participants were found HR HPV positive in both FTA card and PreservCyt samples, and 19 (6.53%) women were diagnosed as CIN2+. The HR HPV positive rate on samples collected by FTA Elute card and PreservCyt solution was 42.61% and 39.86%, respectively. The overall agreement was 87% (kappa=0.731) between FTA card and PreservCyt. The clinical sensitivity and specificity of FTA card and PreservCyt were 100%, 61.39% and 100%, 64.33%, respectively. In this study, FTA Elute card demonstrated a good performance on self-collected sample for HR HPV detection in HIV-1 positive population. For the women from low-resource area with HIV-1 infection, FTA Elute card could be an attractive sample collection method for cervical cancer screening. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Analysis of Duplicated Multiple-Samples Rank Data Using the Mack-Skillings Test.

    PubMed

    Carabante, Kennet Mariano; Alonso-Marenco, Jose Ramon; Chokumnoyporn, Napapan; Sriwattana, Sujinda; Prinyawiwatkul, Witoon

    2016-07-01

    Appropriate analysis for duplicated multiple-samples rank data is needed. This study compared analysis of duplicated rank preference data using the Friedman versus Mack-Skillings tests. Panelists (n = 125) ranked twice 2 orange juice sets: different-samples set (100%, 70%, vs. 40% juice) and similar-samples set (100%, 95%, vs. 90%). These 2 sample sets were designed to get contrasting differences in preference. For each sample set, rank sum data were obtained from (1) averaged rank data of each panelist from the 2 replications (n = 125), (2) rank data of all panelists from each of the 2 separate replications (n = 125 each), (3) jointed rank data of all panelists from the 2 replications (n = 125), and (4) rank data of all panelists pooled from the 2 replications (n = 250); rank data (1), (2), and (4) were separately analyzed by the Friedman test, although those from (3) by the Mack-Skillings test. The effect of sample sizes (n = 10 to 125) was evaluated. For the similar-samples set, higher variations in rank data from the 2 replications were observed; therefore, results of the main effects were more inconsistent among methods and sample sizes. Regardless of analysis methods, the larger the sample size, the higher the χ(2) value, the lower the P-value (testing H0 : all samples are not different). Analyzing rank data (2) separately by replication yielded inconsistent conclusions across sample sizes, hence this method is not recommended. The Mack-Skillings test was more sensitive than the Friedman test. Furthermore, it takes into account within-panelist variations and is more appropriate for analyzing duplicated rank data. © 2016 Institute of Food Technologists®

  20. False Positivity of Non-Targeted Infections in Malaria Rapid Diagnostic Tests: The Case of Human African Trypanosomiasis

    PubMed Central

    Gillet, Philippe; Mumba Ngoyi, Dieudonné; Lukuka, Albert; Kande, Viktor; Atua, Benjamin; van Griensven, Johan; Muyembe, Jean-Jacques; Jacobs, Jan; Lejon, Veerle

    2013-01-01

    Background In endemic settings, diagnosis of malaria increasingly relies on the use of rapid diagnostic tests (RDTs). False positivity of such RDTs is poorly documented, although it is especially relevant in those infections that resemble malaria, such as human African trypanosomiasis (HAT). We therefore examined specificity of malaria RDT products among patients infected with Trypanosoma brucei gambiense. Methodology/Principal Findings Blood samples of 117 HAT patients and 117 matched non-HAT controls were prospectively collected in the Democratic Republic of the Congo. Reference malaria diagnosis was based on real-time PCR. Ten commonly used malaria RDT products were assessed including three two-band and seven three-band products, targeting HRP-2, Pf-pLDH and/or pan-pLDH antigens. Rheumatoid factor was determined in PCR negative subjects. Specificity of the 10 malaria RDT products varied between 79.5 and 100% in HAT-negative controls and between 11.3 and 98.8% in HAT patients. For seven RDT products, specificity was significantly lower in HAT patients compared to controls. False positive reactions in HAT were mainly observed for pan-pLDH test lines (specificities between 13.8 and 97.5%), but also occurred frequently for the HRP-2 test line (specificities between 67.9 and 98.8%). The Pf-pLDH test line was not affected by false-positive lines in HAT patients (specificities between 97.5 and 100%). False positivity was not associated to rheumatoid factor, detected in 7.6% of controls and 1.2% of HAT patients. Conclusions/Significance Specificity of some malaria RDT products in HAT was surprisingly low, and constitutes a risk for misdiagnosis of a fatal but treatable infection. Our results show the importance to assess RDT specificity in non-targeted infections when evaluating diagnostic tests. PMID:23638201

  1. Modeling the Declining Positivity Rates for Human Immunodeficiency Virus Testing in New York State.

    PubMed

    Martin, Erika G; MacDonald, Roderick H; Smith, Lou C; Gordon, Daniel E; Lu, Tao; OʼConnell, Daniel A

    2015-01-01

    New York health care providers have experienced declining percentages of positive human immunodeficiency virus (HIV) tests among patients. Furthermore, observed positivity rates are lower than expected on the basis of the national estimate that one-fifth of HIV-infected residents are unaware of their infection. We used mathematical modeling to evaluate whether this decline could be a result of declining numbers of HIV-infected persons who are unaware of their infection, a measure that is impossible to measure directly. A stock-and-flow mathematical model of HIV incidence, testing, and diagnosis was developed. The model includes stocks for uninfected, infected and unaware (in 4 disease stages), and diagnosed individuals. Inputs came from published literature and time series (2006-2009) for estimated new infections, newly diagnosed HIV cases, living diagnosed cases, mortality, and diagnosis rates in New York. Primary model outcomes were the percentage of HIV-infected persons unaware of their infection and the percentage of HIV tests with a positive result (HIV positivity rate). In the base case, the estimated percentage of unaware HIV-infected persons declined from 14.2% in 2006 (range, 11.9%-16.5%) to 11.8% in 2010 (range, 9.9%-13.1%). The HIV positivity rate, assuming testing occurred independent of risk, was 0.12% in 2006 (range, 0.11%-0.15%) and 0.11% in 2010 (range, 0.10%-0.13%). The observed HIV positivity rate was more than 4 times the expected positivity rate based on the model. HIV test positivity is a readily available indicator, but it cannot distinguish causes of underlying changes. Findings suggest that the percentage of unaware HIV-infected New Yorkers is lower than the national estimate and that the observed HIV test positivity rate is greater than expected if infected and uninfected individuals tested at the same rate, indicating that testing efforts are appropriately targeting undiagnosed cases.

  2. False positive malaria rapid diagnostic test in returning traveler with typhoid fever.

    PubMed

    Meatherall, Bonnie; Preston, Keith; Pillai, Dylan R

    2014-07-09

    Rapid diagnostic tests play a pivotal role in the early diagnosis of malaria where microscopy or polymerase chain reaction are not immediately available. We report the case of a 39 year old traveler to Canada who presented with fever, headache, and abdominal pain after visiting friends and relatives in India. While in India, the individual was not ill and had no signs or symptoms of malaria. Laboratory testing upon his return to Canada identified a false positive malaria rapid diagnostic (BinaxNOW® malaria) result for P. falciparum with coincident Salmonella Typhi bacteraemia without rheumatoid or autoimmune factors. Rapid diagnostic test false positivity for malaria coincided with the presence or absence of Salmonella Typhi in the blood. Clinicians should be aware that Salmonella Typhi infection may result in a false positive malaria rapid diagnostic test. The mechanism of this cross-reactivity is not clear.

  3. Comparison of initial stream urine samples and cervical samples for detection of human papillomavirus.

    PubMed

    Hagihara, Mao; Yamagishi, Yuka; Izumi, Koji; Miyazaki, Narimi; Suzuki, Takayoshi; Kato, Hideo; Nishiyama, Naoya; Koizumi, Yusuke; Suematsu, Hiroyuki; Mikamo, Hiroshige

    2016-08-01

    Uterine cervical cancer is a treatable and preventable cancer. Medical efforts to reduce rates of cervical cancer focus on the promotion of human papillomavirus (HPV) vaccination and the promotion of routine cervical cancer screening done by cervical cytology and cervical HPV testing. Urine-based HPV testing would be simple and noninvasive approach to screen for cervical cancer. Two biospecimens (clinician-taken sample from cervix and initial stream urine sample) were provided from a total of 240 healthy women attending for cancer screening provided for HPV testing. We have assessed the HPV detection rates among cervical samples and pellet fraction of urine samples using HPV test (Anyplex™ II HPV28 Detection kit, Seegene, Korea). Among 240 samples screened, HPV prevalence was 42.9% in pellet fractions of urine samples. The agreement between the two kinds of samples was 98.4%, k = 0.792. Discordant results were observed in 27 cases; 5 were positive only by urine samples and 22 were positive only by smear samples. Sensitivity and specificity for all HPV DNA in pellet fractions of urine using cervical samples as reference was 68.4% and 99.9%. Comparing methodologies of collection of samples for HPV detection, they showed the higher agreements for almost genotypes between cervical samples and pellet fractions of urine samples. These results suggest that urine could be a good noninvasive tool to monitor HPV infection in women. Additional research in a larger and general screening population would be needed. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  4. Testing the non-unity of rate ratio under inverse sampling.

    PubMed

    Tang, Man-Lai; Liao, Yi Jie; Ng, Hong Keung Tony; Chan, Ping Shing

    2007-08-01

    Inverse sampling is considered to be a more appropriate sampling scheme than the usual binomial sampling scheme when subjects arrive sequentially, when the underlying response of interest is acute, and when maximum likelihood estimators of some epidemiologic indices are undefined. In this article, we study various statistics for testing non-unity rate ratios in case-control studies under inverse sampling. These include the Wald, unconditional score, likelihood ratio and conditional score statistics. Three methods (the asymptotic, conditional exact, and Mid-P methods) are adopted for P-value calculation. We evaluate the performance of different combinations of test statistics and P-value calculation methods in terms of their empirical sizes and powers via Monte Carlo simulation. In general, asymptotic score and conditional score tests are preferable for their actual type I error rates are well controlled around the pre-chosen nominal level, and their powers are comparatively the largest. The exact version of Wald test is recommended if one wants to control the actual type I error rate at or below the pre-chosen nominal level. If larger power is expected and fluctuation of sizes around the pre-chosen nominal level are allowed, then the Mid-P version of Wald test is a desirable alternative. We illustrate the methodologies with a real example from a heart disease study. (c) 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

  5. The relationship between personalities and self-report positive driving behavior in a Chinese sample

    PubMed Central

    Sun, Xianghong; Zhang, Kan

    2018-01-01

    Driving behaviors play an important role in accident involvement. Concretely speaking, aberrant driving behaviors would cause more accidents, and oppositely positive driving behaviors would promote to build safety traffic environment. The main goals of this study were to explore the positive driving behavior and its relationship with personality in a Chinese sample. A total of 421 licensed drivers (286 male and 135 female) from Beijing, China completed the Positive Driver Behavior Scale (PDBS), the Driver Behavior Questionnaire (DBQ), the Dula Dangerous Driving Index (DDDI) and the Big Five Inventory (BFI) on a voluntary and anonymous basis. The results showed that the Chinese version of the PDBS has both reliability and validity and that the PDBS was significantly correlated with the BFI. Specifically, the PDBS was negatively correlated with neuroticism (r = -0.38) and positively correlated with extraversion, agreeableness, conscientiousness and openness to experience (the correlation coefficient ranged from 0.36 to 0.55). In contrast with previous research, age was negatively correlated with the PDBS (r = -0.38) in our sample, which may have resulted from less driving experience or a lack of available cognitive resources. PMID:29324823

  6. The relationship between personalities and self-report positive driving behavior in a Chinese sample.

    PubMed

    Shen, Biying; Qu, Weina; Ge, Yan; Sun, Xianghong; Zhang, Kan

    2018-01-01

    Driving behaviors play an important role in accident involvement. Concretely speaking, aberrant driving behaviors would cause more accidents, and oppositely positive driving behaviors would promote to build safety traffic environment. The main goals of this study were to explore the positive driving behavior and its relationship with personality in a Chinese sample. A total of 421 licensed drivers (286 male and 135 female) from Beijing, China completed the Positive Driver Behavior Scale (PDBS), the Driver Behavior Questionnaire (DBQ), the Dula Dangerous Driving Index (DDDI) and the Big Five Inventory (BFI) on a voluntary and anonymous basis. The results showed that the Chinese version of the PDBS has both reliability and validity and that the PDBS was significantly correlated with the BFI. Specifically, the PDBS was negatively correlated with neuroticism (r = -0.38) and positively correlated with extraversion, agreeableness, conscientiousness and openness to experience (the correlation coefficient ranged from 0.36 to 0.55). In contrast with previous research, age was negatively correlated with the PDBS (r = -0.38) in our sample, which may have resulted from less driving experience or a lack of available cognitive resources.

  7. How conservative is Fisher's exact test? A quantitative evaluation of the two-sample comparative binomial trial.

    PubMed

    Crans, Gerald G; Shuster, Jonathan J

    2008-08-15

    The debate as to which statistical methodology is most appropriate for the analysis of the two-sample comparative binomial trial has persisted for decades. Practitioners who favor the conditional methods of Fisher, Fisher's exact test (FET), claim that only experimental outcomes containing the same amount of information should be considered when performing analyses. Hence, the total number of successes should be fixed at its observed level in hypothetical repetitions of the experiment. Using conditional methods in clinical settings can pose interpretation difficulties, since results are derived using conditional sample spaces rather than the set of all possible outcomes. Perhaps more importantly from a clinical trial design perspective, this test can be too conservative, resulting in greater resource requirements and more subjects exposed to an experimental treatment. The actual significance level attained by FET (the size of the test) has not been reported in the statistical literature. Berger (J. R. Statist. Soc. D (The Statistician) 2001; 50:79-85) proposed assessing the conservativeness of conditional methods using p-value confidence intervals. In this paper we develop a numerical algorithm that calculates the size of FET for sample sizes, n, up to 125 per group at the two-sided significance level, alpha = 0.05. Additionally, this numerical method is used to define new significance levels alpha(*) = alpha+epsilon, where epsilon is a small positive number, for each n, such that the size of the test is as close as possible to the pre-specified alpha (0.05 for the current work) without exceeding it. Lastly, a sample size and power calculation example are presented, which demonstrates the statistical advantages of implementing the adjustment to FET (using alpha(*) instead of alpha) in the two-sample comparative binomial trial. 2008 John Wiley & Sons, Ltd

  8. Development and evaluation of a highly sensitive immunochromatographic strip test using gold nanoparticle for direct detection of Vibrio cholerae O139 in seafood samples.

    PubMed

    Pengsuk, Chalinan; Chaivisuthangkura, Parin; Longyant, Siwaporn; Sithigorngul, Paisarn

    2013-04-15

    A strip test for the detection of Vibrio cholerae O139 was developed using two monoclonal antibodies (MAbs), namely VC-273 and VC-812, which specifically bind to the lipopolysaccharide and capsular polysaccharide of V. cholerae O139. The MAb VC-273 gold nanoparticle conjugate was sprayed onto a glass fiber pad that was placed adjacent to a sample chamber. MAb VC-812 and the goat anti-mouse immunoglobulin G (GAM) antibody were sprayed onto a nitrocellulose membrane in strips at positions designated as T and C, respectively. The test strips were assessed for their ability to directly detect V. cholerae O139 using samples dispersed in application buffer, and a 100 μL aliquot of sample was applied to the sample chamber. The results were observable within 20 min after application of the sample. In samples containing V. cholerae O139, the antigen was bound to the colloidal gold-conjugated MAb to form an antibody-antigen complex. This complex was captured by the MAbs at the T test line, resulting in the appearance of a reddish-purple band at the T position. The sensitivity of the test was determined to be 10⁴ cfu mL⁻¹. Direct detection of V. cholerae O139 in various fresh seafood samples could be accomplished with similar sensitivities. The detection limit was substantially improved to 1 cfu mL⁻¹ of the original bacterial content after pre-incubation of the sample in alkaline peptone water for 12 h. The V. cholerae strip test provides several advantages over other methods, including the speed and simplicity of use because there is no requirement for sophisticated equipment. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Characterization of the modified Hodge test-positive isolates of Enterobacteriaceae in Taiwan.

    PubMed

    Hung, Kuei-Hsiang; Yan, Jing-Jou; Lu, Jang-Jih; Chen, Hung-Mo; Wu, Jiunn-Jong

    2013-02-01

    The modified Hodge test is a phenotypic test to detect KPC-type carbapenemase producers among Enterobacteriaceae, as recommended by the Clinical Laboratory Standards Institute. However, false positive results were reported. In this study, we aimed to large-scale investigate the characterization of the modified Hodge test-positive isolates of Enterobacteriaceae collected between 2006 and 2010 in Taiwan. Fifty-six isolates, including 24 Enterobacter cloacae, 17 Escherichia coli, 10 Klebsiella pneumoniae, and 5 Citrobacter freundii, tested positive with the modified Hodge test. The in vitro activities of 10 antimicrobial agents were determined by the agar dilution method. Boronic acid combined-disk test was used to further confirm the KPC producers. Phenotype of ESBL, AmpC, class B carbapenemases, and profile of outer membrane proteins were investigated by the confirmatory test, boronic acid disk method, 2-mercaptopropionic acid double-disk method, and urea/sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), respectively. β-lactamase genes were examined by PCR and sequencing. These isolates were resistant to ceftazidime (100%), aztreonam (82.1%), ertapenem (64.3%), gentamicin (53.6%), ciprofloxacin (50%), levofloxacin (48.2%), cefepime (19.6%), imipenem (16.1%), meropenem (12.5%), and amikacin (8.9%). Phenotypic testing among isolates revealed the production of ESBLs, metallo-β-lactamases (MBLs), and AmpC in 10 (17.9%), 16 (28.6%), and 12 (44.4%) isolates, respectively. Carbapenemase and non-carbapenemase β-lactamase genes bla(TEM-1), bla(SHV), bla(CTX-M), bla(IMP-8), bla(CMY-2), and bla(DHA-1) were found in 32 (57.1%), 19 (33.9%), 4 (7.1%), 16 (28.6%), 14 (25%), and 5 (8.9%) of the strains, respectively. No class A and D carbapenemase genes were detected. Outer membrane protein profile showed obviously decreased expression in 49 (87.5%) isolates with positive result of modified Hodge test. Our data show that ESBLs, AmpC, and imipenemase-8 (IMP-8

  10. For Men: A Positive Zika Virus Test, What Does It Mean for Me?

    MedlinePlus

    CDC’s Response to Zika FOR MEN: A POSITIVE ZIKA VIRUS TEST What does it mean for me? You’ve just learned from your ... or healthcare provider that you have a positive Zika test result, which means that you have Zika ...

  11. Empirical Validation of a Procedure to Correct Position and Stimulus Biases in Matching-to-Sample

    ERIC Educational Resources Information Center

    Kangas, Brian D.; Branch, Marc N.

    2008-01-01

    The development of position and stimulus biases often occurs during initial training on matching-to-sample tasks. Furthermore, without intervention, these biases can be maintained via intermittent reinforcement provided by matching-to-sample contingencies. The present study evaluated the effectiveness of a correction procedure designed to…

  12. Self-Sampling for Human Papillomavirus Testing among Non-Attenders Increases Attendance to the Norwegian Cervical Cancer Screening Programme

    PubMed Central

    Enerly, Espen; Bonde, Jesper; Schee, Kristina; Pedersen, Helle; Lönnberg, Stefan; Nygård, Mari

    2016-01-01

    Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV) testing as an alternative to a clinical sampling can be a useful policy to increase attendance. To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP), 800 women aged 25–69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited to be part of the intervention group. Women in this group received one of two self-sampling devices, Evalyn Brush or Delphi Screener. To attend screening, women in the intervention group had the option of using the self-sampling device (self-sampling subgroup) or visiting their physician for a cervical smear. Self-sampled specimens were split and analyzed for the presence of high-risk (hr) HPV by the CLART® HPV2 test and the digene® Hybrid Capture (HC)2 test. The control group consisted of 2593 women who received a 2nd reminder letter according to the current guidelines of the NCCSP. The attendance rates were 33.4% in the intervention group and 23.2% in the control group, with similar attendance rates for both self-sampling devices. Women in the self-sampling subgroup responded favorably to both self-sampling devices and cited not remembering receiving a call for screening as the most dominant reason for previous non-attendance. Thirty-two of 34 (94.1%) hrHPV-positive women in the self-sampling subgroup attended follow-up. In conclusion, self-sampling increased attendance rates and was feasible and well received. This study lends further support to the proposal that self-sampling may be a valuable alternative for increasing cervical cancer screening coverage in Norway. PMID:27073929

  13. Self-Sampling for Human Papillomavirus Testing among Non-Attenders Increases Attendance to the Norwegian Cervical Cancer Screening Programme.

    PubMed

    Enerly, Espen; Bonde, Jesper; Schee, Kristina; Pedersen, Helle; Lönnberg, Stefan; Nygård, Mari

    2016-01-01

    Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV) testing as an alternative to a clinical sampling can be a useful policy to increase attendance. To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP), 800 women aged 25-69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited to be part of the intervention group. Women in this group received one of two self-sampling devices, Evalyn Brush or Delphi Screener. To attend screening, women in the intervention group had the option of using the self-sampling device (self-sampling subgroup) or visiting their physician for a cervical smear. Self-sampled specimens were split and analyzed for the presence of high-risk (hr) HPV by the CLART® HPV2 test and the digene® Hybrid Capture (HC)2 test. The control group consisted of 2593 women who received a 2nd reminder letter according to the current guidelines of the NCCSP. The attendance rates were 33.4% in the intervention group and 23.2% in the control group, with similar attendance rates for both self-sampling devices. Women in the self-sampling subgroup responded favorably to both self-sampling devices and cited not remembering receiving a call for screening as the most dominant reason for previous non-attendance. Thirty-two of 34 (94.1%) hrHPV-positive women in the self-sampling subgroup attended follow-up. In conclusion, self-sampling increased attendance rates and was feasible and well received. This study lends further support to the proposal that self-sampling may be a valuable alternative for increasing cervical cancer screening coverage in Norway.

  14. [Interpretation of false positive results of biochemical prenatal tests].

    PubMed

    Sieroszewski, Piotr; Słowakiewicz, Katarzyna; Perenc, Małgorzata

    2010-03-01

    Modern, non-invasive prenatal diagnostics based on biochemical and ultrasonographic markers of fetal defects allows us to calculate the risk of fetal chromosomal aneuploidies with high sensitivity and specificity An introduction of biochemical, non-invasive prenatal tests turned out to result in frequent false positive results of these tests in cases when invasive diagnostics does not confirm fetal defects. However prospective analysis of these cases showed numerous complications in the third trimester of the pregnancies.

  15. Laboratory Tests of Bitumen Samples Elasticity

    NASA Astrophysics Data System (ADS)

    Ziganshin, E. R.; Usmanov, S. A.; Khasanov, D. I.; Khamidullina, G. S.

    2018-05-01

    This paper is devoted to the study of the elastic and acoustic properties of bitumen core samples. The travel velocities of the ultrasonic P- and S-waves were determined under in-situ simulation conditions. The resulting data were then used to calculate dynamic Young's modulus and Poisson's ratio. The authors studied the correlation between the elasticity and the permeability and porosity. In addition, the tests looked into how the acoustic properties had changed with temperature rise.

  16. HCV knowledge among a sample of HCV positive Aboriginal Australians residing in New South Wales.

    PubMed

    Wilson, Hannah; Brener, Loren; Jackson, L Clair; Saunders, Veronica; Johnson, Priscilla; Treloar, Carla

    2017-06-01

    Australian Aboriginal and Torres Strait Islanders are overrepresented in both the prevalence and incidence of the hepatitis C (HCV). HCV knowledge has been associated with a range of positive health behaviours. HCV knowledge has previously been investigated as a single construct; however examining different knowledge domains (i.e. transmission, risk of complications, testing and treatment) separately may be beneficial. This study investigated whether having greater HCV knowledge in different domains is associated with self-reported positive health behaviours. 203 Aboriginal people living with HCV completed a survey assessing HCV knowledge, testing and care, lifestyle changes since diagnosis and treatment intent. Respondents' knowledge was relatively high. Greater knowledge of risk of health complications was associated with undertaking more positive lifestyle changes since diagnosis. Respondents testing and treatment knowledge was significantly associated with incarceration, lifestyle changes since diagnosis and future treatment intentions. This study illustrates the importance of ensuring that knowledge is high across different HCV domains to optimise a range of positive health behaviours of Aboriginal people living with HCV. Future health promotion campaigns targeted at Aboriginal people living with HCV could benefit from broadening their focus from prevention to other domains such as testing and treatment.

  17. Identification and Susceptibility Testing of Enterobacteriaceae and Pseudomonas aeruginosa by Direct Inoculation from Positive BACTEC Blood Culture Bottles into Vitek 2

    PubMed Central

    Bruins, Marjan J.; Bloembergen, Peter; Ruijs, Gijs J. H. M.; Wolfhagen, Maurice J. H. M.

    2004-01-01

    Inoculation of an automated system for rapid identification (ID) and antimicrobial susceptibility testing (AST) directly from positive blood culture bottles will reduce the turnaround time of laboratory diagnosis of septicemic patients, which benefits clinical outcome and decreases patient costs. Direct test results, however, must always be confirmed by testing a pure overnight culture, which is the “gold standard.” We studied the accuracy of direct testing versus repeat testing in order to investigate the possibility of refraining from repeat testing. We also assessed the clinical risk of reporting results based on direct testing only. We inoculated Vitek 2 (bioMérieux) directly from 410 positive BACTEC 9240 (BD) blood culture bottles containing gram-negative rods and studied the ID and AST results. In a comparison of direct inoculation with the standard method, a total of 344 isolates of Enterobacteriaceae and Pseudomonas aeruginosa were tested, and 93.0% were correctly identified. Of the 39 (10.2%) samples that contained bacilli not identifiable by Vitek 2, only 1 gave a conclusive, correct result. The overall MIC agreement among 312 isolates was 99.2%, with 0.8% very major and 0.02% major error rates. Of only three (polymicrobial) samples, the direct susceptibility pattern would be reported to the clinician as too sensitive. Vitek 2 results obtained from direct inoculation of blood culture bottles containing gram-negative bacilli are safe enough for immediate reporting, provided that ID and AST are consistent. Repeat testing is not necessary, unless Gram stain or overnight subculture results raise doubt about the purity of the culture. PMID:14715724

  18. Phoenix Test Sample Site in Color

    NASA Technical Reports Server (NTRS)

    2008-01-01

    This color image, acquired by NASA's Phoenix Mars Lander's Surface Stereo Imager on Sol 7, the seventh day of the mission (June 1, 2008), shows the so-called 'Knave of Hearts' first-dig test area to the north of the lander. The Robotic Arm's scraping blade left a small horizontal depression above where the sample was taken.

    Scientists speculate that white material in the depression left by the dig could represent ice or salts that precipitated into the soil. This material is likely the same white material observed in the sample in the Robotic Arm's scoop.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  19. Development of green fluorescent protein-expressing bacterial strains and evaluation for potential use as positive controls in sample analyses.

    PubMed

    Noah, Charles W; Shaw, Christine I; Ikeda, Jack S; Kreuzer, Karen S; Sofos, John N

    2005-04-01

    Strains of enterohemorrhagic Escherichia coli O157:H7 and Salmonella Typhimurium were engineered to express the gene for a modified green fluorescent protein (GFP) and were evaluated for potential use as positive controls in sample analyses. The strains fluoresced when observed as colonies with a handheld UV lamp or as individual cells under a fluorescent microscope. The strains maintained their fluorescence following growth in three series of transfer experiments including 8 to 11 passages from broth to broth and twice for 15 consecutive transfers from broth onto Trypticase soy agar plates. Cultures also maintained stability in the ability to fluoresce when agar plates were refrigerated (4 degrees C) for up to 12 days. Growth characteristics of the GFP-positive strains were comparable to those of corresponding control strains. The GFP-positive strains were successfully identified using rapid diagnostic methods and were differentiated from their corresponding non-GFP strains by pulsed-field gel electrophoresis but not by repetitive extragenic palindromic PCR. The GFP-positive and the control strains were recovered successfully from individually inoculated food samples (Feta cheese, raw shrimp, cooked shrimp, and cooked crawfish). However, in one Feta cheese sample and one raw shrimp sample inoculated with combined GFP-positive and GFP-negative cultures, colonies of the GFP-positive strains were not observed under UV light; fluorescing cells in one of the inoculated samples (raw shrimp) were revealed by microscopy. In general, the isolates from the inoculated foods were GFP positive by microscopic examination; the pure isolates could also be restreaked onto Trypticase soy agar, and colonies could be visually examined under UV light. Because GFP strains are not known to occur naturally in the environment, the use of the Salmonella GFP-positive strain may offer advantages as a positive control even when distinct and rare serotypes are available. The GFP-positive E

  20. False positive fecal coliform in biosolid samples assayed using A-1 medium.

    PubMed

    Baker, Katherine H; Redmond, Brady; Herson, Diane S

    2005-01-01

    Two most probable number (MPN) methods-lauryl tryptose broth with Escherichia coli broth confirmation and direct A-1 broth incubation (A-1)--were compared for the enumeration of fecal coliform in lime-treated biosolid. Fecal coliform numbers were significantly higher using the A-1 method. Analysis of positive A-1 tubes, however, indicated that a high percentage of these were false positives. Therefore, the use of A-1 broth for 40 CFR Part 503 Pathogen Reduction (CFR, 1993) compliance testing is not recommended.

  1. Upper Limb Neural Tension and Seated Slump Tests: The False Positive Rate among Healthy Young Adults without Cervical or Lumbar Symptoms

    PubMed Central

    Davis, D. Scott; Anderson, Ila Beth; Carson, Mary Grace; Elkins, Caroline L.; Stuckey, Lindsey B.

    2008-01-01

    This study examined the false positive rate of the upper limb neural tension test (ULNTT) and seated slump test (SST) among healthy young adults with no history of cervical, lumbar, or peripheral symptoms. Eighty-four subjects (27 men and 57 women) with a mean age of 22.9 years participated in the investigation. All participants completed a screening questionnaire designed to exclude subjects with a history of cervical or lumbar spine pain or injury, or upper or lower extremity neurological symptoms. The ULNTT and the SST were performed on the left upper and lower extremity of each participant. Of the 84 participants tested, 73 (86.9%) were found to have a positive ULNTT at some point in the available range of elbow extension. Twenty-eight (33.3%) of the 84 subjects had a positive SST at some point in the available range of knee extension. The mean knee extension angle for those subjects with a positive SST was 15.1° with a 95% confidence interval (CI) of 12.3 and 19.7°. The mean elbow extension angle for those with a positive ULNTT was 49.4° with a 95% CI of 44.8 and 54.0°. The number of positive tests for both the ULNTT and the SST was found to be high in this sample of asymptomatic healthy young adults. Based on the results of this investigation, the authors suggest that the current criteria for determining a positive test for both the ULNTT and the SST should be examined using the proposed range of motion cut-off scores. PMID:19119402

  2. 40 CFR 205.57-2 - Test vehicle sample selection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Test vehicle sample selection. 205.57-2 Section 205.57-2 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Medium and Heavy Trucks § 205.57-2 Test...

  3. Development of a new protocol for rapid bacterial identification and susceptibility testing directly from urine samples.

    PubMed

    Zboromyrska, Y; Rubio, E; Alejo, I; Vergara, A; Mons, A; Campo, I; Bosch, J; Marco, F; Vila, J

    2016-06-01

    The current gold standard method for the diagnosis of urinary tract infections (UTI) is urine culture that requires 18-48 h for the identification of the causative microorganisms and an additional 24 h until the results of antimicrobial susceptibility testing (AST) are available. The aim of this study was to shorten the time of urine sample processing by a combination of flow cytometry for screening and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for bacterial identification followed by AST directly from urine. The study was divided into two parts. During the first part, 675 urine samples were processed by a flow cytometry device and a cut-off value of bacterial count was determined to select samples for direct identification by MALDI-TOF-MS at ≥5 × 10(6) bacteria/mL. During the second part, 163 of 1029 processed samples reached the cut-off value. The sample preparation protocol for direct identification included two centrifugation and two washing steps. Direct AST was performed by the disc diffusion method if a reliable direct identification was obtained. Direct MALDI-TOF-MS identification was performed in 140 urine samples; 125 of the samples were positive by urine culture, 12 were contaminated and 3 were negative. Reliable direct identification was obtained in 108 (86.4%) of the 125 positive samples. AST was performed in 102 identified samples, and the results were fully concordant with the routine method among 83 monomicrobial infections. In conclusion, the turnaround time of the protocol described to diagnose UTI was about 1 h for microbial identification and 18-24 h for AST. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  4. Impact of grey zone sample testing by enzyme-linked immunosorbent assay in enhancing blood safety: Experience at a tertiary care hospital in North India.

    PubMed

    Solanki, Archana; Singh, Abhay; Chaudhary, Rajendra

    2016-01-01

    Enzyme-linked immunosorbent assay (ELISA) used for screening blood donors for transfusion transmitted infections (TTIs) can sometimes fail to detect blood donors who are recently infected or possessing the low strength of pathogen. Estimation of a grey zone in ELISA testing and repeat testing of grey zone samples can further help in reducing the risks of TTI in countries where nucleic acid amplification testing for TTIs is not feasible. Grey zone samples with optical density (OD) lying between cut-off OD and 10% below the cut-off OD (cut-off OD × 0.9) were identified during routine ELISA testing. On performing repeat ELISA testing on grey zone samples in duplicate, the samples showing both OD value below grey zone were marked nonreactive, and samples showing one or both OD value in the grey zone were marked indeterminate. The samples on repeat testing showing one or both OD above cut-off value were marked positive. About 119 samples (77 for hepatitis B virus [HBV], 23 for human immunodeficiency virus [HIV], and 19 for hepatitis C virus [HCV]) were found to be in grey zone. On repeat testing of these samples in duplicate, 70 (58.8%) samples (45 for HBV, 12 for HIV, and 13 for HCV) were found to be reactive. Six (5%) samples (four for HBV, one for HIV, and one for HCV) were found to be indeterminate. Seventy donors initially screened negative, were found out to be potentially infectious on repeat grey zone testing. Thus, estimation of grey zone samples with repeat testing can further enhance the safety of blood transfusion.

  5. GICHD Mine Dog Testing Project - Soil Sample Results No.3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PHELAN, JAMES M.; BARNETT, JAMES L.; BENDER, SUSAN FAE ANN

    2003-03-01

    A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan and Bosnia containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performancemore » and seasonal weather conditions. This report documents the analytical chemical methods and results from the third batch of soils received. This batch contained samples from Kharga, Afghanistan collected in October 2002.« less

  6. Estimation of infection prevalence and sensitivity in a stratified two-stage sampling design employing highly specific diagnostic tests when there is no gold standard.

    PubMed

    Miller, Ezer; Huppert, Amit; Novikov, Ilya; Warburg, Alon; Hailu, Asrat; Abbasi, Ibrahim; Freedman, Laurence S

    2015-11-10

    In this work, we describe a two-stage sampling design to estimate the infection prevalence in a population. In the first stage, an imperfect diagnostic test was performed on a random sample of the population. In the second stage, a different imperfect test was performed in a stratified random sample of the first sample. To estimate infection prevalence, we assumed conditional independence between the diagnostic tests and develop method of moments estimators based on expectations of the proportions of people with positive and negative results on both tests that are functions of the tests' sensitivity, specificity, and the infection prevalence. A closed-form solution of the estimating equations was obtained assuming a specificity of 100% for both tests. We applied our method to estimate the infection prevalence of visceral leishmaniasis according to two quantitative polymerase chain reaction tests performed on blood samples taken from 4756 patients in northern Ethiopia. The sensitivities of the tests were also estimated, as well as the standard errors of all estimates, using a parametric bootstrap. We also examined the impact of departures from our assumptions of 100% specificity and conditional independence on the estimated prevalence. Copyright © 2015 John Wiley & Sons, Ltd.

  7. The Bootstrap, the Jackknife, and the Randomization Test: A Sampling Taxonomy.

    PubMed

    Rodgers, J L

    1999-10-01

    A simple sampling taxonomy is defined that shows the differences between and relationships among the bootstrap, the jackknife, and the randomization test. Each method has as its goal the creation of an empirical sampling distribution that can be used to test statistical hypotheses, estimate standard errors, and/or create confidence intervals. Distinctions between the methods can be made based on the sampling approach (with replacement versus without replacement) and the sample size (replacing the whole original sample versus replacing a subset of the original sample). The taxonomy is useful for teaching the goals and purposes of resampling schemes. An extension of the taxonomy implies other possible resampling approaches that have not previously been considered. Univariate and multivariate examples are presented.

  8. Positive perception of pharmacogenetic testing for psychotropic medications

    PubMed Central

    Lanktree, Matthew B; Zai, Gwyneth; VanderBeek, Laura E; Giuffra, Daniel E; Smithson, David S; Kipp, Lucas B; Dalseg, Timothy R; Speechley, Mark; Kennedy, James L

    2014-01-01

    Introduction Pharmacogenetics attempts to identify inter-individual genetic differences that are predictive of variable drug response and propensity to side effects, with the prospect of assisting physicians to select the most appropriate drug and dosage for treatment. However, many concerns regarding genetic tests exist. We sought to test the opinions of undergraduate science and medical students in southern Ontario universities toward pharmacogenetic testing. Methods and Results Questionnaires were completed by 910 undergraduate medicine and science students from 2005 to 2007. Despite students' concerns that the results of genetic tests may be used for other purposes without consent (71%) or lead to discrimination (78%), an overwhelming number of students were in favor of pharmacogenetic testing (90%). Discussion To our knowledge, this study is the first to survey a large sample for their attitude toward pharmacogenetic testing for psychotropic medications. Our results indicate that, although concerns remain and scientific advancements are required, respondents were in support of pharmacogenetic testing for medications used to treat schizophrenia. © 2014 The Authors. Human Psychopharmacology: Clinical and Experimental published by John Wiley & Sons, Ltd. PMID:24604560

  9. Specificity and false positive rates of the Test of Memory Malingering, Rey 15-item Test, and Rey Word Recognition Test among forensic inpatients with intellectual disabilities.

    PubMed

    Love, Christopher M; Glassmire, David M; Zanolini, Shanna Jordan; Wolf, Amanda

    2014-10-01

    This study evaluated the specificity and false positive (FP) rates of the Rey 15-Item Test (FIT), Word Recognition Test (WRT), and Test of Memory Malingering (TOMM) in a sample of 21 forensic inpatients with mild intellectual disability (ID). The FIT demonstrated an FP rate of 23.8% with the standard quantitative cutoff score. Certain qualitative error types on the FIT showed promise and had low FP rates. The WRT obtained an FP rate of 0.0% with previously reported cutoff scores. Finally, the TOMM demonstrated low FP rates of 4.8% and 0.0% on Trial 2 and the Retention Trial, respectively, when applying the standard cutoff score. FP rates are reported for a range of cutoff scores and compared with published research on individuals diagnosed with ID. Results indicated that although the quantitative variables on the FIT had unacceptably high FP rates, the TOMM and WRT had low FP rates, increasing the confidence clinicians can place in scores reflecting poor effort on these measures during ID evaluations. © The Author(s) 2014.

  10. Fresh vs Frozen Samples and Ambient Temperature Have Little Effect on Detection of Colorectal Cancer or Adenomas by a Fecal Immunochemical Test in a Colorectal Cancer Screening Cohort in Germany.

    PubMed

    Chen, Hongda; Werner, Simone; Brenner, Hermann

    2017-10-01

    Fecal immunochemical tests (FITs) are used in colorectal cancer (CRC) screening. We compared detection of CRCs and colorectal neoplasms by FITs using fresh samples (collected into buffer-filled tubes) vs frozen samples, and we assessed the effects of seasonal variations in ambient temperature on test performance. We performed a prospective study of 3466 individuals (50% male; mean age, 62 years) undergoing screening colonoscopies at 20 gastroenterology practices in southern Germany from November 2008 through September 2014. Frozen stool samples (collected and frozen by patients through February 2012, n = 1644) and fresh stool samples (collected by patients into buffer-filled tubes after February 2012, n = 1822) were obtained; hemoglobin (Hgb) concentrations were measured by using a commercial, quantitative FIT (cutoff value for positive result, 17 μg Hgb/g feces). Colonoscopy results were used as the gold standard, with results categorized as CRC, advanced adenoma, non-advanced adenoma, or no colorectal neoplasm. Differences in detection of colorectal neoplasms with fresh vs frozen samples were compared by using Wilcoxon rank sum test (continuous variables) and Fisher exact test (categorical variables). We also compared test performance when samples were collected during different seasons (based on outdoor temperature less than 8°, 8°-15°, or more than 15°). Of the samples analyzed by FIT, 12.8% of frozen stool samples (95% confidence interval [CI], 11.3%-14.5%) and 8.7% of fresh stool samples (95% CI, 7.5%-10.1%) had positive results (P value for difference < .001). When adjusting the Hgb cutoff value to produce the same percentage of positive results for fresh and frozen samples (10% and 5%), FIT with frozen vs fresh samples detected colorectal neoplasms with similar levels of sensitivity and specificity. For example, at cutoff values that produced 5% positive results for each sample type, FIT detected advanced neoplasms with 27.8% sensitivity when

  11. Optimization of techniques for multiple platform testing in small, precious samples such as human chorionic villus sampling.

    PubMed

    Pisarska, Margareta D; Akhlaghpour, Marzieh; Lee, Bora; Barlow, Gillian M; Xu, Ning; Wang, Erica T; Mackey, Aaron J; Farber, Charles R; Rich, Stephen S; Rotter, Jerome I; Chen, Yii-der I; Goodarzi, Mark O; Guller, Seth; Williams, John

    2016-11-01

    Multiple testing to understand global changes in gene expression based on genetic and epigenetic modifications is evolving. Chorionic villi, obtained for prenatal testing, is limited, but can be used to understand ongoing human pregnancies. However, optimal storage, processing and utilization of CVS for multiple platform testing have not been established. Leftover CVS samples were flash-frozen or preserved in RNAlater. Modifications to standard isolation kits were performed to isolate quality DNA and RNA from samples as small as 2-5 mg. RNAlater samples had significantly higher RNA yields and quality and were successfully used in microarray and RNA-sequencing (RNA-seq). RNA-seq libraries generated using 200 versus 800-ng RNA showed similar biological coefficients of variation. RNAlater samples had lower DNA yields and quality, which improved by heating the elution buffer to 70 °C. Purification of DNA was not necessary for bisulfite-conversion and genome-wide methylation profiling. CVS cells were propagated and continue to express genes found in freshly isolated chorionic villi. CVS samples preserved in RNAlater are superior. Our optimized techniques provide specimens for genetic, epigenetic and gene expression studies from a single small sample which can be used to develop diagnostics and treatments using a systems biology approach in the prenatal period. © 2016 John Wiley & Sons, Ltd. © 2016 John Wiley & Sons, Ltd.

  12. One-sided truncated sequential t-test: application to natural resource sampling

    Treesearch

    Gary W. Fowler; William G. O' Regan

    1974-01-01

    A new procedure for constructing one-sided truncated sequential t-tests and its application to natural resource sampling are described. Monte Carlo procedures were used to develop a series of one-sided truncated sequential t-tests and the associated approximations to the operating characteristic and average sample number functions. Different truncation points and...

  13. Compressive-sampling-based positioning in wireless body area networks.

    PubMed

    Banitalebi-Dehkordi, Mehdi; Abouei, Jamshid; Plataniotis, Konstantinos N

    2014-01-01

    Recent achievements in wireless technologies have opened up enormous opportunities for the implementation of ubiquitous health care systems in providing rich contextual information and warning mechanisms against abnormal conditions. This helps with the automatic and remote monitoring/tracking of patients in hospitals and facilitates and with the supervision of fragile, elderly people in their own domestic environment through automatic systems to handle the remote drug delivery. This paper presents a new modeling and analysis framework for the multipatient positioning in a wireless body area network (WBAN) which exploits the spatial sparsity of patients and a sparse fast Fourier transform (FFT)-based feature extraction mechanism for monitoring of patients and for reporting the movement tracking to a central database server containing patient vital information. The main goal of this paper is to achieve a high degree of accuracy and resolution in the patient localization with less computational complexity in the implementation using the compressive sensing theory. We represent the patients' positions as a sparse vector obtained by the discrete segmentation of the patient movement space in a circular grid. To estimate this vector, a compressive-sampling-based two-level FFT (CS-2FFT) feature vector is synthesized for each received signal from the biosensors embedded on the patient's body at each grid point. This feature extraction process benefits in the combination of both short-time and long-time properties of the received signals. The robustness of the proposed CS-2FFT-based algorithm in terms of the average positioning error is numerically evaluated using the realistic parameters in the IEEE 802.15.6-WBAN standard in the presence of additive white Gaussian noise. Due to the circular grid pattern and the CS-2FFT feature extraction method, the proposed scheme represents a significant reduction in the computational complexity, while improving the level of the

  14. Distribution of the two-sample t-test statistic following blinded sample size re-estimation.

    PubMed

    Lu, Kaifeng

    2016-05-01

    We consider the blinded sample size re-estimation based on the simple one-sample variance estimator at an interim analysis. We characterize the exact distribution of the standard two-sample t-test statistic at the final analysis. We describe a simulation algorithm for the evaluation of the probability of rejecting the null hypothesis at given treatment effect. We compare the blinded sample size re-estimation method with two unblinded methods with respect to the empirical type I error, the empirical power, and the empirical distribution of the standard deviation estimator and final sample size. We characterize the type I error inflation across the range of standardized non-inferiority margin for non-inferiority trials, and derive the adjusted significance level to ensure type I error control for given sample size of the internal pilot study. We show that the adjusted significance level increases as the sample size of the internal pilot study increases. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  15. 40 CFR 53.57 - Test for filter temperature control during sampling and post-sampling periods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Test for filter temperature control... Class I and Class II Equivalent Methods for PM 2.5 or PM 10-2.5 § 53.57 Test for filter temperature... candidate sampler's ability to prevent excessive overheating of the PM sample collection filter (or filters...

  16. 40 CFR 53.57 - Test for filter temperature control during sampling and post-sampling periods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 6 2013-07-01 2013-07-01 false Test for filter temperature control... Class I and Class II Equivalent Methods for PM 2.5 or PM 10-2,5 § 53.57 Test for filter temperature... candidate sampler's ability to prevent excessive overheating of the PM sample collection filter (or filters...

  17. Development and Testing of a ``Backlash-Free'' Gas-Tight High Precision Sample Handling Mechanism for Combined Science on the ExoMars 2018 Rover

    NASA Astrophysics Data System (ADS)

    Paul, R.; Redlich, D.; Richter, L.; Zuknik, K.-H.; Muhlbauer, Q.; Thiel, M.; Fowler, L.; Tattusch, T.; Weisz, H.; Musso, F.; Durrant, S.

    2015-09-01

    This paper presents the development and testing by the OHB System AG of the Powdered Sample Handling Mechanism (PSHS) that is part of the rover of the European Space Agency 2018 ExoMars Mission, a cooperative mission with Roscosmos including a scientific instrument contribution from NASA. The task of this mechanism is to flatten and position powdered Martian soil samples allowing subsequent investigation of selected grains by different optical instruments thus providing combined science in an ultra-clean environment.The exceptional sensitivity of these instruments causes extremely challenging requirements with respect to positioning performance as well as cleanliness and contamination control. The impact of these design drivers is highlighted focusing on specific mechanism features such as the pre-torque device to minimize the backlash and the dynamic feed-through, allowing a gas-tight encapsulation of an ultra-clean zone free of drive-train components.Subsequently the results of the test campaign of an elegant breadboard under Mars-like conditions, as well as first QM test results are described. Furthermore the outcomes of combined tests with an optical instrument are reported.

  18. Supplementary biochemical tests useful for the differentiation of oxidase positive staphylococci.

    PubMed

    Stepanović, Srdjan; Dakić, Ivana; Hauschild, Tomasz; Vuković, Dragana; Morrison, Donald; Jezek, Petr; Cirković, Ivana; Petrás, Petr

    2007-06-01

    Differentiation of the oxidase positive staphylococci, Staphylococcus sciuri, Staphylococcus lentus, Staphylococcus vitulinus and Staphylococcus fleurettii, based on tributyrin, urease, caseinase, gelatinase and DNase activity is described. These tests may be used for preliminary identification of oxidase positive isolates of staphylococci resulting in more accurate identification of these species.

  19. Testing a Positive Psychological Intervention for Osteoarthritis.

    PubMed

    Hausmann, Leslie R M; Youk, Ada; Kwoh, C Kent; Ibrahim, Said A; Hannon, Michael J; Weiner, Debra K; Gallagher, Rollin M; Parks, Acacia

    2017-10-01

    Osteoarthritis is a leading cause of disability for which there is no cure. Psychosocial-oriented treatments are underexplored. We developed and tested an intervention to build positive psychological skills (e.g., gratitude) to reduce osteoarthritis symptom severity, including pain and functioning, and to improve psychosocial well-being in patients with knee or hip osteoarthritis. Two-arm randomized design with six-month follow-up. An academic Veterans Affairs Medical Center. Patients aged 50 years or older with knee or hip osteoarthritis and pain ratings of 4 or higher. Patients (N = 42) were randomized to a six-week program containing positive skill-building activities or neutral control activities tailored to the patient population. Adherence was assessed by telephone each week. We assessed osteoarthritis symptom severity (WOMAC Osteoarthritis Index) and measures of well-being (positive affect, negative affect, and life satisfaction) at baseline and by telephone one, three, and six months after the program ended. We used linear mixed models to examine changes over time. The majority (64%) of patients completed more than 80% of their weekly activities. Patients in the positive (vs neutral) program reported significantly more improvement over time in osteoarthritis symptom severity (P = 0.02, Cohen's d = 0.86), negative affect (P = 0.03, Cohen's d = 0.50), and life satisfaction (P = 0.02, Cohen's d = 0.36). The study successfully engaged patients with knee or hip osteoarthritis in a six-week intervention to build positive psychological skills. Improving osteoarthritis symptom severity and measures of psychosocial well-being, the intervention shows promise as a tool for chronic pain management. 2017 American Academy of Pain Medicine. This work is written by US Government employees and is in the public domain in the US.

  20. Simple Sample Processing Enhances Malaria Rapid Diagnostic Test Performance

    PubMed Central

    Davis, K. M.; Gibson, L. E.; Haselton, F. R.; Wright, D. W.

    2016-01-01

    Lateral flow immunochromatographic rapid diagnostic tests (RDTs) are the primary form of medical diagnostic used for malaria in underdeveloped nations. Unfortunately, many of these tests do not detect asymptomatic malaria carriers. In order for eradication of the disease to be achieved, this problem must be solved. In this study, we demonstrate enhancement in the performance of six RDT brands when a simple sample-processing step is added to the front of the diagnostic process. Greater than a 4-fold RDT signal enhancement was observed as a result of the sample processing step. This lowered the limit of detection for RDT brands to submicroscopic parasitemias. For the best performing RDTs the limits of detection were found to be as low as 3 parasites/μL. Finally, through individual donor samples, the correlations between donor source, WHO panel detection scores and RDT signal intensities were explored. PMID:24787948

  1. Simple sample processing enhances malaria rapid diagnostic test performance.

    PubMed

    Davis, K M; Gibson, L E; Haselton, F R; Wright, D W

    2014-06-21

    Lateral flow immunochromatographic rapid diagnostic tests (RDTs) are the primary form of medical diagnostic used for malaria in underdeveloped nations. Unfortunately, many of these tests do not detect asymptomatic malaria carriers. In order for eradication of the disease to be achieved, this problem must be solved. In this study, we demonstrate enhancement in the performance of six RDT brands when a simple sample-processing step is added to the front of the diagnostic process. Greater than a 4-fold RDT signal enhancement was observed as a result of the sample processing step. This lowered the limit of detection for RDT brands to submicroscopic parasitemias. For the best performing RDTs the limits of detection were found to be as low as 3 parasites per μL. Finally, through individual donor samples, the correlations between donor source, WHO panel detection scores and RDT signal intensities were explored.

  2. Microbial identification and automated antibiotic susceptibility testing directly from positive blood cultures using MALDI-TOF MS and VITEK 2.

    PubMed

    Wattal, C; Oberoi, J K

    2016-01-01

    The study addresses the utility of Matrix Assisted Laser Desorption/Ionisation Time-Of-Flight mass spectrometry (MALDI-TOF MS) using VITEK MS and the VITEK 2 antimicrobial susceptibility testing (AST) system for direct identification (ID) and timely AST from positive blood culture bottles using a lysis-filtration method (LFM). Between July and December 2014, a total of 140 non-duplicate mono-microbial blood cultures were processed. An aliquot of positive blood culture broth was incubated with lysis buffer before the bacteria were filtered and washed. Micro-organisms recovered from the filter were first identified using VITEK MS and its suspension was used for direct AST by VITEK 2 once the ID was known. Direct ID and AST results were compared with classical methods using solid growth. Out of the 140 bottles tested, VITEK MS resulted in 70.7 % correct identification to the genus and/ or species level. For the 103 bottles where identification was possible, there was agreement in 97 samples (94.17 %) with classical culture. Compared to the routine method, the direct AST resulted in category agreement in 860 (96.5 %) of 891 bacteria-antimicrobial agent combinations tested. The results of direct ID and AST were available 16.1 hours before those of the standard approach on average. The combined use of VITEK MS and VITEK 2 directly on samples from positive blood culture bottles using a LFM technique can result in rapid and reliable ID and AST results in blood stream infections to result in early institution of targeted treatment. The combination of LFM and AST using VITEK 2 was found to expedite AST more reliably.

  3. 40 CFR 53.57 - Test for filter temperature control during sampling and post-sampling periods.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Test for filter temperature control... Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 § 53.57 Test for filter temperature... candidate sampler's ability to prevent excessive overheating of the PM sample collection filter (or filters...

  4. 40 CFR 53.57 - Test for filter temperature control during sampling and post-sampling periods.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test for filter temperature control... Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 § 53.57 Test for filter temperature... candidate sampler's ability to prevent excessive overheating of the PM sample collection filter (or filters...

  5. 40 CFR 53.57 - Test for filter temperature control during sampling and post-sampling periods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 6 2012-07-01 2012-07-01 false Test for filter temperature control... Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 § 53.57 Test for filter temperature... candidate sampler's ability to prevent excessive overheating of the PM sample collection filter (or filters...

  6. The Utility of IRT in Small-Sample Testing Applications.

    ERIC Educational Resources Information Center

    Sireci, Stephen G.

    The utility of modified item response theory (IRT) models in small sample testing applications was studied. The modified IRT models were modifications of the one- and two-parameter logistic models. One-, two-, and three-parameter models were also studied. Test data were from 4 years of a national certification examination for persons desiring…

  7. Green-coloured results on guaiac-based faecal occult blood testing should be considered positive.

    PubMed

    Gordon, Joy C; Steele, R Jc; Fraser, C G

    2004-11-01

    In guaiac-based faecal occult blood tests (FOBT), blue colours are considered positive. Blue-green colours should also be considered positive. Distinct green colours are said to be due to bile and it is stated that these should be interpreted as negative. The purpose of this study was to determine the clinical outcomes in individuals in whom the FOBT had difficult-to-interpret green colours that did not wash out on addition of developer. During the examination of 134 844 FOBT received in the Scottish laboratory in the first screening round of the UK Colorectal Cancer Screening Pilot, samples with green colour that did not wash out during development were identified. The clinical outcomes were determined from the comprehensive data set collected for each participant. A small number (77) of FOBT were recorded as green-coloured on development. These were reported as positive and the usual investigation algorithm followed. Significant pathology was present in 31 of the 77 participants (40.3%). Negative outcomes encompassed 39 of the 77 participants (50.6%). The outcome could not be determined accurately for seven of the 77 participants (9.1%). Importantly, 17 of the participants (22.1%) had polyps. Any green colour that does not wash out to the periphery of the guaiac tape on development of FOBT should be reported as a positive result, and manufacturers should clarify their instructions on interpretation.

  8. Multiplex Identification of Gram-Positive Bacteria and Resistance Determinants Directly from Positive Blood Culture Broths: Evaluation of an Automated Microarray-Based Nucleic Acid Test

    PubMed Central

    Buchan, Blake W.; Ginocchio, Christine C.; Manii, Ryhana; Cavagnolo, Robert; Pancholi, Preeti; Swyers, Lettie; Thomson, Richard B.; Anderson, Christopher; Kaul, Karen; Ledeboer, Nathan A.

    2013-01-01

    Background A multicenter study was conducted to evaluate the diagnostic accuracy (sensitivity and specificity) of the Verigene Gram-Positive Blood Culture Test (BC-GP) test to identify 12 Gram-positive bacterial gene targets and three genetic resistance determinants directly from positive blood culture broths containing Gram-positive bacteria. Methods and Findings 1,252 blood cultures containing Gram-positive bacteria were prospectively collected and tested at five clinical centers between April, 2011 and January, 2012. An additional 387 contrived blood cultures containing uncommon targets (e.g., Listeria spp., S. lugdunensis, vanB-positive Enterococci) were included to fully evaluate the performance of the BC-GP test. Sensitivity and specificity for the 12 specific genus or species targets identified by the BC-GP test ranged from 92.6%–100% and 95.4%–100%, respectively. Identification of the mecA gene in 599 cultures containing S. aureus or S. epidermidis was 98.6% sensitive and 94.3% specific compared to cefoxitin disk method. Identification of the vanA gene in 81 cultures containing Enterococcus faecium or E. faecalis was 100% sensitive and specific. Approximately 7.5% (87/1,157) of single-organism cultures contained Gram-positive bacteria not present on the BC-GP test panel. In 95 cultures containing multiple organisms the BC-GP test was in 71.6% (68/95) agreement with culture results. Retrospective analysis of 107 separate blood cultures demonstrated that identification of methicillin resistant S. aureus and vancomycin resistant Enterococcus spp. was completed an average of 41.8 to 42.4 h earlier using the BC-GP test compared to routine culture methods. The BC-GP test was unable to assign mecA to a specific organism in cultures containing more than one Staphylococcus isolate and does not identify common blood culture contaminants such as Micrococcus, Corynebacterium, and Bacillus. Conclusions The BC-GP test is a multiplex test capable of detecting most

  9. Testing of candidate non-lethal sampling methods for detection of Renibacterium salmoninarum in juvenile Chinook salmon Oncorhynchus tshawytscha

    USGS Publications Warehouse

    Elliott, Diane G.; McKibben, Constance L.; Conway, Carla M.; Purcell, Maureen K.; Chase, Dorothy M.; Applegate, Lynn M.

    2015-01-01

    Non-lethal pathogen testing can be a useful tool for fish disease research and management. Our research objectives were to determine if (1) fin clips, gill snips, surface mucus scrapings, blood draws, or kidney biopsies could be obtained non-lethally from 3 to 15 g Chinook salmon Oncorhynchus tshawytscha, (2) non-lethal samples could accurately discriminate between fish exposed to the bacterial kidney disease agent Renibacterium salmoninarum and non-exposed fish, and (3) non-lethal samples could serve as proxies for lethal kidney samples to assess infection intensity. Blood draws and kidney biopsies caused ≥5% post-sampling mortality (Objective 1) and may be appropriate only for larger fish, but the other sample types were non-lethal. Sampling was performed over 21 wk following R. salmoninarum immersion challenge of fish from 2 stocks (Objectives 2 and 3), and nested PCR (nPCR) and real-time quantitative PCR (qPCR) results from candidate non-lethal samples were compared with kidney tissue analysis by nPCR, qPCR, bacteriological culture, enzyme-linked immunosorbent assay (ELISA), fluorescent antibody test (FAT) and histopathology/immunohistochemistry. R. salmoninarum was detected by PCR in >50% of fin, gill, and mucus samples from challenged fish. Mucus qPCR was the only non-lethal assay exhibiting both diagnostic sensitivity and specificity estimates >90% for distinguishing between R. salmoninarum-exposed and non-exposed fish and was the best candidate for use as an alternative to lethal kidney sample testing. Mucus qPCR R. salmoninarum quantity estimates reflected changes in kidney bacterial load estimates, as evidenced by significant positive correlations with kidney R. salmoninaruminfection intensity scores at all sample times and in both fish stocks, and were not significantly impacted by environmentalR. salmoninarum concentrations.

  10. The withholding of test results as a means of assessing the effectiveness of treatment in test-positive persons.

    PubMed

    Weiss, Noel S

    2013-04-01

    In recent years, a number of studies have achieved randomization of patients to alternative management strategies by blinding some patients (and their providers of medical care) to the results of tests that guide such strategies. Although this research approach has the potential to be a powerful means of measuring treatment effectiveness, the interpretation of the results may not be straightforward if the treatment received by test-positive persons is variable or not well documented, or if the analysis is not restricted to outcomes in test-positive persons. Studies in which the test results are withheld at random may face ethical issues that, to date, have received little discussion. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Using pH testing to confirm nasogastric tube position.

    PubMed

    Earley, Tracy

    In 2004 the MHRA published a directive for all hospitals in the UK to use pH paper in place of litmus paper when testing position of nasogastric tubes (NGT). This article illustrates one trust's implementation of this process of change in order to achieve compliance.

  12. Compressive and Flexural Tests on Adobe Samples Reinforced with Wire Mesh

    NASA Astrophysics Data System (ADS)

    Jokhio, G. A.; Al-Tawil, Y. M. Y.; Syed Mohsin, S. M.; Gul, Y.; Ramli, N. I.

    2018-03-01

    Adobe is an economical, naturally available, and environment friendly construction material that offers excellent thermal and sound insulations as well as indoor air quality. It is important to understand and enhance the mechanical properties of this material, where a high degree of variation is reported in the literature owing to lack of research and standardization in this field. The present paper focuses first on the understanding of mechanical behaviour of adobe subjected to compressive stresses as well as flexure and then on enhancing the same with the help of steel wire mesh as reinforcement. A total of 22 samples were tested out of which, 12 cube samples were tested for compressive strength, whereas 10 beams samples were tested for modulus of rupture. Half of the samples in each category were control samples i.e. without wire mesh reinforcement, whereas the remaining half were reinforced with a single layer of wire mesh per sample. It has been found that the compressive strength of adobe increases by about 43% after adding a single layer of wire mesh reinforcement. The flexural response of adobe has also shown improvement with the addition of wire mesh reinforcement.

  13. Confirmation of nasogastric tube position by pH testing.

    PubMed

    Taylor, S J; Clemente, R

    2005-10-01

    In 2004, the Medicines and Healthcare products Regulatory Agency (MHRA) advised that nasogastric (NG) tube position should be confirmed using pH strips or paper. However, gastric pH is raised by the use of H2-blockers and proton-pump inhibitors (PPIs) potentially producing false negative pH tests resulting in delayed feeding. In addition, colorimetric differentiation using pH strips may be more prone to bias and inaccuracy than direct pH measurements largely used to establish the threshold. To quantify this problem a 1 day survey of all the patients requiring NG and nasointestinal (NI) feeding was undertaken, to establish the numbers of patients receiving H2-Blockers or PPIs, with or without a safe swallow and the methods currently being used to confirm tube positioning. A second observational study was performed to establish the accuracy of six pH strips available to NHS trusts against four unlabelled pH solutions. Forty-two per cent of patients receiving NG feeding were on H2-blockers or PPIs, including 13% who had a safe swallow for acidic drinks that could be subsequently aspirated to confirm position. In the second study 'testers' correctly identified pH's 3, 4, 5 and 6 with Mackery-Nagel 0-6, BDH 0-6 and 0-14 strips but overestimated pH 4 as pH 5 with Johnson 0-11 paper, underestimated pH 6 as pH 5 with Pehanon 0-12 paper and with Litmus classified pH 3-5 as acid (all), but half also classified pH 6 as acid. Theoretically 29% of NG tube positions could not be confirmed by pH testing because of the usage of PPIs or H2-blockers and lack of swallow. Some pH strips are either inaccurate or their result misinterpreted by staff. Large surveys and trials of the actual efficacy and accuracy of pH testing are required.

  14. An Efficient Referencing And Sample Positioning System To Investigate Heterogeneous Substances With Combined Microfocused Synchrotron X-ray Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spangenberg, Thomas; Goettlicher, Joerg; Steininger, Ralph

    2009-01-29

    A referencing and sample positioning system has been developed to transfer object positions measured with an offline microscope to a synchrotron experimental station. The accuracy should be sufficient to deal with heterogeneous samples on micrometer scale. Together with an online fluorescence mapping visualisation the optical alignment helps to optimize measuring procedures for combined microfocused X-ray techniques.

  15. A Nonparametric K-Sample Test for Equality of Slopes.

    ERIC Educational Resources Information Center

    Penfield, Douglas A.; Koffler, Stephen L.

    1986-01-01

    The development of a nonparametric K-sample test for equality of slopes using Puri's generalized L statistic is presented. The test is recommended when the assumptions underlying the parametric model are violated. This procedure replaces original data with either ranks (for data with heavy tails) or normal scores (for data with light tails).…

  16. Six consecutive false positive cases from cell-free fetal DNA testing in a single referring centre

    PubMed Central

    Dugo, Nella; Padula, Francesco; Mobili, Luisa; Brizzi, Cristiana; D’Emidio, Laura; Cignini, Pietro; Mesoraca, Alvaro; Bizzoco, Domenico; Cima, Antonella; Giorlandino, Claudio

    2014-01-01

    Introduction recent studies have proposed the introduction of cell-free fetal DNA testing (NIPT-Non Invasive Prenatal Testing) in routine clinical practice emphasizing its high sensibility and specificity. In any case, false positive and false negative findings may result from placental mosaicism, because cell-free fetal DNA originates mainly from placenta. Case we report six cases of women who underwent chorionic villus sampling (CVS) or amniocentesis to confirm the results from NIPT: two Turner syndromes, two Triple X, one Patau syndrome, one Edward syndrome. Results using classic cytogenetic analysis and, also, Array - Comparative Genomic Hybridization (Array CGH) the karyotype of all 5 fetuses was found to be normal. Conclusion results from NIPT must always be confirmed by invasive prenatal diagnosis. It is mandatory to inform the patient that the CVS and amniocentesis still represent the only form of prenatal diagnostic test available. PMID:25332757

  17. Sport-Specific Motor Fitness Tests in Water Polo: Reliability, Validity and Playing Position Differences

    PubMed Central

    Uljevic, Ognjen; Spasic, Miodrag; Sekulic, Damir

    2013-01-01

    Sport-specific motor fitness tests are not often examined in water polo. In this study we examined the reliability, factorial and discriminative validity of 10 water-polo-specific motor-fitness tests, namely: three tests of in-water jumps (thrusts), two characteristic swimming sprints (10 and 20 metres from the water start), three ball-throws (shoots), one test of passing precision (accuracy), and a test of the dynamometric force produced while using the eggbeater kick. The sample of subjects consisted of 54 young male water polo players (15 to 17 years of age; 1.86 ± 0.07 m, and 83.1 ± 9.9 kg). All tests were applied over three testing trials. Reliability analyses included Cronbach Alpha coefficients (CA), inter-item- correlations (IIR) and coefficients of the variation (CV), while an analysis of variance was used to define any systematic bias between the testing trials. All tests except the test of accuracy (precision) were found to be reliable (CA ranged from 0.83 to 0.97; IIR from 0.62 to 0.91; CV from 2% to 21%); with small and irregular biases between the testing trials. Factor analysis revealed that jumping capacities as well as throwing and sprinting capacities should be observed as a relatively independent latent dimensions among young water polo players. Discriminative validity of the applied tests is partially proven since the playing positions significantly (p < 0.05) differed in some of the applied tests, with the points being superior in their fitness capacities in comparison to their teammates. This study included players from one of the world’s best junior National leagues, and reported values could be used as fitness standards for such an age. Further studies are needed to examine the applicability of the proposed test procedures to older subjects and females. Key Points Here presented and validated sport specific water polo motor fitness tests are found to be reliable in the sample of young male water polo players. Factor analysis revealed

  18. Proof of concept testing of a positive reference material for in vivo and in vitro skin irritation testing.

    PubMed

    Nomura, Yusuke; Lee, Michelle; Fukui, Chie; Watanabe, Kayo; Olsen, Daniel; Turley, Audrey; Morishita, Yuki; Kawakami, Tsuyoshi; Yuba, Toshiyasu; Fujimaki, Hideo; Inoue, Kaoru; Yoshida, Midori; Ogawa, Kumiko; Haishima, Yuji

    2017-12-11

    In vivo and in vitro irritation testing is important for evaluating the biological safety of medical devices. Here, the performance of positive reference materials for skin irritation testing was evaluated. Four reference standards, referred to as Y-series materials, were analyzed: a polyvinyl chloride (PVC) sheet spiked with 0 (Y-1), 1.0 (Y-2), 1.5 (Y-3), or 10 (Y-4) parts of Genapol X-080 per 100 parts of PVC by weight. Y-1, Y-2, and Y-3 did not induce skin irritation responses in an in vitro reconstructed human epidermis (RhE) tissue model, as measured by tissue viability or interleukin-1α release, or in an in vivo intracutaneous response test using rabbits. In contrast, Y-4 extracts prepared with saline or sesame oil at 37°C and 50°C clearly elicited positive irritation responses, including reduced viability (< 50%) and significantly higher interleukin-1α release compared with the solvent alone group, in the RhE tissue model and an intracutaneous response test, where substantial necrosis was observed by histopathology. The positive skin irritation responses induced in vitro under various extraction conditions, as well as those elicited in vivo, indicate that Y-4 is an effective extractable positive control material for in vivo and in vitro skin irritation tests of medical devices. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2017. © 2017 Wiley Periodicals, Inc.

  19. Sample processing approach for detection of ricin in surface samples.

    PubMed

    Kane, Staci; Shah, Sanjiv; Erler, Anne Marie; Alfaro, Teneile

    2017-12-01

    With several ricin contamination incidents reported over the past decade, rapid and accurate methods are needed for environmental sample analysis, especially after decontamination. A sample processing method was developed for common surface sampling devices to improve the limit of detection and avoid false negative/positive results for ricin analysis. Potential assay interferents from the sample matrix (bleach residue, sample material, wetting buffer), including reference dust, were tested using a Time-Resolved Fluorescence (TRF) immunoassay. Test results suggested that the sample matrix did not cause the elevated background fluorescence sometimes observed when analyzing post-bleach decontamination samples from ricin incidents. Furthermore, sample particulates (80mg/mL Arizona Test Dust) did not enhance background fluorescence or interfere with ricin detection by TRF. These results suggested that high background fluorescence in this immunoassay could be due to labeled antibody quality and/or quantity issues. Centrifugal ultrafiltration devices were evaluated for ricin concentration as a part of sample processing. Up to 30-fold concentration of ricin was observed by the devices, which serve to remove soluble interferents and could function as the front-end sample processing step to other ricin analytical methods. The procedure has the potential to be used with a broader range of environmental sample types and with other potential interferences and to be followed by other ricin analytical methods, although additional verification studies would be required. Published by Elsevier B.V.

  20. Dipstick Test for Rapid Diagnosis of Shigella dysenteriae 1 in Bacterial Cultures and Its Potential Use on Stool Samples

    PubMed Central

    Taneja, Neelam; Nato, Faridabano; Dartevelle, Sylvie; Sire, Jean Marie; Garin, Benoit; Thi Phuong, Lan Nguyen; Diep, Tai The; Shako, Jean Christophe; Bimet, François; Filliol, Ingrid; Muyembe, Jean-Jacques; Ungeheuer, Marie Noëlle; Ottone, Catherine; Sansonetti, Philippe; Germani, Yves

    2011-01-01

    Background We describe a test for rapid detection of S. dysenteriae 1 in bacterial cultures and in stools, at the bedside of patients. Methodology/Principal Findings The test is based on the detection of S. dysenteriae 1 lipopolysaccharide (LPS) using serotype 1-specific monoclonal antibodies coupled to gold particles and displayed on a one-step immunochromatographic dipstick. A concentration as low as 15 ng/ml of LPS was detected in distilled water and in reconstituted stools in 10 minutes. In distilled water and in reconstituted stools, an unequivocal positive reaction was obtained with 1.6×106 CFU/ml and 4.9×106 CFU/ml of S. dysenteriae 1, respectively. Optimal conditions to read the test have been determined to limit the risk of ambiguous results due to appearance of a faint yellow test band in some negative samples. The specificity was 100% when tested with a battery of Shigella and unrelated strains in culture. When tested on 328 clinical samples in India, Vietnam, Senegal and France by laboratory technicians and in Democratic Republic of Congo by a field technician, the specificity (312/316) was 98.7% (95% CI:96.6–99.6%) and the sensitivity (11/12) was 91.7% (95% CI:59.8–99.6%). Stool cultures and the immunochromatographic test showed concordant results in 98.4 % of cases (323/328) in comparative studies. Positive and negative predictive values were 73.3% (95% CI:44.8–91.1%) and 99.7% (95% CI:98–100%). Conclusion The initial findings presented here for a simple dipstick-based test to diagnose S. dysenteriae 1 demonstrates its promising potential to become a powerful tool for case management and epidemiological surveys. PMID:21984895

  1. Low-Pressure Testing of the Mars Science Laboratory’s Solid Sampling System: Test Methods and Preliminary Results

    NASA Astrophysics Data System (ADS)

    Mukherjee, S.; von der Heydt, M.; Hanson, C.; Jandura, L.

    2009-12-01

    The Mars Science Laboratory mission is scheduled to launch in 2011 with an extensive suite of in situ science instruments. Acquiring, processing and delivering appropriate samples of rock and martian regolith to the instruments is a critical component in realizing the science capability of these payload elements. However, there are a number of challenges in validating the design of these systems. In particular, differences in the environment (atmospheric pressure and composition, temperature, gravity), target materials (variation in rock and soil properties), and state of the hardware (electrical potential, particulate coatings) may effect sampling performance. To better understand the end-to-end system and allow development of mitigation strategies if necessary, early testing of high-fidelity engineering models of the hardware in the solid sample chain is being conducted. The components of the sample acquisition, processing & delivery chain that will be tested are the drill, scoop, sieves, portioners, and instrument inlet funnels. An evaluation of the environmental parameter space was conducted to identify a subset that may have significant effects on sampling performance and cannot be well bounded by analysis. Accordingly, support equipment to enable testing at Mars surface pressures (5-10 Torr), with carbon dioxide was designed and built. A description of the testing set-up, investigations, and preliminary results will be presented.

  2. Psychometric properties of the Positive and Negative Affect Schedule (PANAS) in a heterogeneous sample of substance users.

    PubMed

    Serafini, Kelly; Malin-Mayor, Bo; Nich, Charla; Hunkele, Karen; Carroll, Kathleen M

    2016-03-01

    The Positive and Negative Affect Schedule (PANAS) is a widely used measure of affect. A comprehensive psychometric evaluation among substance users, however, has not been published. To examine the psychometric properties of the PANAS in a sample of outpatient treatment substance users. We used pooled data from four randomized clinical trials (N = 416; 34% female, 48% African American). A confirmatory factor analysis indicated adequate support for a two-factor correlated model comprised of Positive Affect and Negative Affect with correlated item errors (Comparative Fit Index = 0.93, Root Mean Square Error of Approximation = 0.07, χ(2) = 478.93, df = 156). Cronbach's α indicated excellent internal consistency for both factors (0.90 and 0.91, respectively). The PANAS factors had good convergence and discriminability (Composite Reliability > 0.7; Maximum Shared Variance < Average Variance Extracted). A comparison from baseline to Week 1 indicated acceptable test-retest reliability (Positive Affect = 0.80, Negative Affect = 0.76). Concurrent and discriminant validity were demonstrated with correlations with the Brief Symptom Inventory and Addiction Severity Index. The PANAS scores were also significantly correlated with treatment outcomes (e.g. Positive Affect was associated with the maximum days of consecutive abstinence from primary substance of abuse, r = 0.16, p = 0.001). Our data suggest that the psychometric properties of the PANAS are retained in substance using populations. Although several studies have focused on the role of Negative Affect, our findings suggest that Positive Affect may also be an important factor in substance use treatment outcomes.

  3. Psychometric properties of the positive and negative affect schedule (PANAS) in a heterogeneous sample of substance users

    PubMed Central

    Serafini, Kelly; Malin-Mayor, Bo; Nich, Charla; Hunkele, Karen; Carroll, Kathleen M.

    2016-01-01

    Background The Positive and Negative Affect Schedule (PANAS) is a widely used measure of affect, and a comprehensive psychometric evaluation has never been conducted among substance users. Objective To examine the psychometric properties of the PANAS in a sample of outpatient treatment substance users. Methods We used pooled data from four randomized clinical trials (N = 416; 34% female, 48% African American). Results A confirmatory factor analysis indicated adequate support for a two-factor correlated model comprised of Positive Affect and Negative Affect with correlated item errors (Comparative Fit Index = .93, Root Mean Square Error of Approximation = .07, χ2 = 478.93, df = 156). Cronbach’s α indicated excellent internal consistency for both factors (.90 and .91, respectively). The PANAS factors had good convergence and discriminability (Composite Reliability >.7; Maximum Shared Variance < Average Variance Extracted). A comparison from baseline to Week 1 indicated acceptable test-retest reliability (Positive Affect = .80, Negative Affect = .76). Concurrent and discriminant validity were demonstrated with correlations with the Brief Symptom Inventory and Addiction Severity Index. The PANAS scores were also significantly correlated with treatment outcomes (e.g., Positive Affect was associated with the maximum days of consecutive abstinence from primary substance of abuse, r = .16, p = .001). Conclusion Our data suggest that the psychometric properties of the PANAS are retained in substance using populations. Although several studies have focused on the role of Negative Affect, our findings suggest that Positive Affect may also be an important factor in substance use treatment outcomes. PMID:26905228

  4. Home Economics. Sample Test Items. Levels I and II.

    ERIC Educational Resources Information Center

    New York State Education Dept., Albany. Bureau of Elementary and Secondary Educational Testing.

    A sample of behavioral objectives and related test items that could be developed for content modules in Home Economics levels I and II, this book is intended to enable teachers to construct more valid and reliable test materials. Forty-eight one-page modules are presented, and opposite each module are listed two to seven specific behavioral…

  5. Masten Space Systems’ Completes Test of Surface Sampling Technology

    NASA Image and Video Library

    2018-06-13

    Honeybee Robotics in Pasadena, California, flight tested its pneumatic sampler collection system, PlanetVac, on Masten Space Systems’ Xodiac rocket on May 24, launching from Mojave, California, and landing to collect a sample of more than 320 grams of top soil from the surface of the desert floor. NASA Flight Opportunities program funded the test flight.

  6. FORTRAN implementation of Friedman's test for several related samples

    NASA Technical Reports Server (NTRS)

    Davidson, S. A.

    1982-01-01

    The FRIEDMAN program is a FORTRAN-coded implementation of Friedman's nonparametric test for several related samples with one observation per treatment/-block combination, or as it is sometimes called, the two-way analysis of variance by ranks. The FRIEDMAN program is described and a test data set and its results are presented to aid potential users of this program.

  7. Estimation of sample size and testing power (Part 4).

    PubMed

    Hu, Liang-ping; Bao, Xiao-lei; Guan, Xue; Zhou, Shi-guo

    2012-01-01

    Sample size estimation is necessary for any experimental or survey research. An appropriate estimation of sample size based on known information and statistical knowledge is of great significance. This article introduces methods of sample size estimation of difference test for data with the design of one factor with two levels, including sample size estimation formulas and realization based on the formulas and the POWER procedure of SAS software for quantitative data and qualitative data with the design of one factor with two levels. In addition, this article presents examples for analysis, which will play a leading role for researchers to implement the repetition principle during the research design phase.

  8. Factors associated with positive direct antiglobulin tests in pretransfusion patients: a case-control study.

    PubMed

    Toy, P T; Chin, C A; Reid, M E; Burns, M A

    1985-01-01

    During routine pretransfusion testing, the presence of IgG on patient red cells is suggested by a positive autocontrol and confirmed by a positive direct antiglobulin test (DAT) using monospecific anti-IgG sera. Most IgG on patient red cells detected in this manner are of unknown etiology. We recently showed an association between elevated serum globulin levels and positive DAT with unreactive eluate in patients with acquired immunodeficiency syndrome (AIDS). In the present study, we wished to determine whether elevated serum globulin levels contribute to some of the positive DAT encountered in pretransfusion testing of patients without AIDS. 76 patients with positive DAT were compared with 90 controls without IgG detected on their red cells during pretransfusion testing. The rate of elevated serum globulin levels was 75% in positive DAT cases versus 29% in controls (p less than 0.001); the odds ratio was 7.6. Elevated blood urea nitrogen levels occurred in 42% of cases versus 19% of controls (p less than 0.025); the odds ratio was 3.1. Cases and controls were not significantly different with regard to age, sex, race, quinidine usage, or hyperalimentation. Elevated serum globulin and blood urea nitrogen levels are significantly associated with a positive DAT with unreactive eluate in pretransfusion patients.

  9. Primary care visit use after positive fecal immunochemical test for colorectal cancer screening.

    PubMed

    Hillyer, Grace Clarke; Jensen, Christopher D; Zhao, Wei K; Neugut, Alfred I; Lebwohl, Benjamin; Tiro, Jasmin A; Kushi, Lawrence H; Corley, Douglas A

    2017-10-01

    For some patients, positive cancer screening test results can be a stressful experience that can affect future screening compliance and increase the use of health care services unrelated to medically indicated follow-up. Among 483,216 individuals aged 50 to 75 years who completed a fecal immunochemical test to screen for colorectal cancer at a large integrated health care setting between 2007 and 2011, the authors evaluated whether a positive test was associated with a net change in outpatient primary care visit use within the year after screening. Multivariable regression models were used to evaluate the relationship between test result group and net changes in primary care visits after fecal immunochemical testing. In the year after the fecal immunochemical test, use increased by 0.60 clinic visits for patients with true-positive results. The absolute change in visits was largest (3.00) among individuals with positive test results who were diagnosed with colorectal cancer, but significant small increases also were found for patients treated with polypectomy and who had no neoplasia (0.36) and those with a normal examination and no polypectomy performed (0.17). Groups of patients who demonstrated an increase in net visit use compared with the true-negative group included patients with true-positive results (odds ratio [OR], 1.60; 95% confidence interval [95% CI], 1.54-1.66), and positive groups with a colorectal cancer diagnosis (OR, 7.19; 95% CI, 6.12-8.44), polypectomy/no neoplasia (OR, 1.37; 95% CI, 1.27-1.48), and normal examination/no polypectomy (OR, 1.24; 95% CI, 1.18-1.30). Given the large size of outreach programs, these small changes can cumulatively generate thousands of excess visits and have a substantial impact on total health care use. Therefore, these changes should be included in colorectal cancer screening cost models and their causes investigated further. Cancer 2017;123:3744-3753. © 2017 American Cancer Society. © 2017 American Cancer Society.

  10. A Third Moment Adjusted Test Statistic for Small Sample Factor Analysis

    PubMed Central

    Lin, Johnny; Bentler, Peter M.

    2012-01-01

    Goodness of fit testing in factor analysis is based on the assumption that the test statistic is asymptotically chi-square; but this property may not hold in small samples even when the factors and errors are normally distributed in the population. Robust methods such as Browne’s asymptotically distribution-free method and Satorra Bentler’s mean scaling statistic were developed under the presumption of non-normality in the factors and errors. This paper finds new application to the case where factors and errors are normally distributed in the population but the skewness of the obtained test statistic is still high due to sampling error in the observed indicators. An extension of Satorra Bentler’s statistic is proposed that not only scales the mean but also adjusts the degrees of freedom based on the skewness of the obtained test statistic in order to improve its robustness under small samples. A simple simulation study shows that this third moment adjusted statistic asymptotically performs on par with previously proposed methods, and at a very small sample size offers superior Type I error rates under a properly specified model. Data from Mardia, Kent and Bibby’s study of students tested for their ability in five content areas that were either open or closed book were used to illustrate the real-world performance of this statistic. PMID:23144511

  11. A Third Moment Adjusted Test Statistic for Small Sample Factor Analysis.

    PubMed

    Lin, Johnny; Bentler, Peter M

    2012-01-01

    Goodness of fit testing in factor analysis is based on the assumption that the test statistic is asymptotically chi-square; but this property may not hold in small samples even when the factors and errors are normally distributed in the population. Robust methods such as Browne's asymptotically distribution-free method and Satorra Bentler's mean scaling statistic were developed under the presumption of non-normality in the factors and errors. This paper finds new application to the case where factors and errors are normally distributed in the population but the skewness of the obtained test statistic is still high due to sampling error in the observed indicators. An extension of Satorra Bentler's statistic is proposed that not only scales the mean but also adjusts the degrees of freedom based on the skewness of the obtained test statistic in order to improve its robustness under small samples. A simple simulation study shows that this third moment adjusted statistic asymptotically performs on par with previously proposed methods, and at a very small sample size offers superior Type I error rates under a properly specified model. Data from Mardia, Kent and Bibby's study of students tested for their ability in five content areas that were either open or closed book were used to illustrate the real-world performance of this statistic.

  12. Doxycycline assay hair samples for testing long-term compliance treatment.

    PubMed

    Angelakis, Emmanouil; Armstrong, Nicholas; Nappez, Claude; Richez, Magalie; Chabriere, Eric; Raoult, Didier

    2015-11-01

    Many patients undergoing long-term doxycycline treatment do not regularly take their treatment because of photosensitivity. Our objective was to create an assay for determining doxycycline levels and to use hair samples for monitoring the compliance over a longer period of time. We tested sera and hair samples from patients treated with doxycycline by a suitable ultra-high performance liquid chromatography (UHPLC) based assay. We estimated that the speed of hair growth is roughly 1.25 cm per month and we were able to determine doxycycline levels over a 6-month period. We tested 14 patients treated with doxycycline and we found similar levels of doxycycline in the serum and the hair samples representing the last 4 months. Linear regression analysis revealed that the level of doxycycline in the serum remained stable over time (p = 0.7) but the level of doxycycline in the hair decreased significantly over time (p = 0.03) indicating a degradation of this molecule in the hair. We detected two patients who did not have antibiotic in the hair, indicating a lack of compliance that was also confirmed by interview. Hair samples can be used to test long-term compliance in patients to explain failures or relapses. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  13. Sample Canister Capture Mechanism for Mars Sample Return: Functional and environmental test of the elegant breadboard model

    NASA Astrophysics Data System (ADS)

    Carta, R.; Filippetto, D.; Lavagna, M.; Mailland, F.; Falkner, P.; Larranaga, J.

    2015-12-01

    The paper provides recent updates about the ESA study: Sample Canister Capture Mechanism Design and Breadboard developed under the Mars Robotic Exploration Preparation (MREP) program. The study is part of a set of feasibility studies aimed at identifying, analysing and developing technology concepts enabling the future international Mars Sample Return (MSR) mission. The MSR is a challenging mission with the purpose of sending a Lander to Mars, acquire samples from its surface/subsurface and bring them back to Earth for further, more in depth, analyses. In particular, the technology object of the Study is relevant to the Capture Mechanism that, mounted on the Orbiter, is in charge of capturing and securing the Sample Canister, or Orbiting Sample, accommodating the Martian soil samples, previously delivered in Martian orbit by the Mars Ascent Vehicle. An elegant breadboard of such a device was implemented and qualified under an ESA contract primed by OHB-CGS S.p.A. and supported by Politecnico di Milano, Department of Aerospace Science and Technology: in particular, functional tests were conducted at PoliMi-DAST and thermal and mechanical test campaigns occurred at Serms s.r.l. facility. The effectiveness of the breadboard design was demonstrated and the obtained results, together with the design challenges, issues and adopted solutions are critically presented in the paper. The breadboard was also tested on a parabolic flight to raise its Technology Readiness Level to 6; the microgravity experiment design, adopted solutions and results are presented as well in the paper.

  14. [Analysis of false-positive reaction for bacterial detection of blood samples with the automated microbial detection system BacT/ALERT 3D].

    PubMed

    Zhu, Li-Wei; Yang, Xue-Mei; Xu, Xiao-Qin; Xu, Jian; Lu, Huang-Jun; Yan, Li-Xing

    2008-10-01

    This study was aimed to analyze the results of false positive reaction in bacterial detection of blood samples with BacT/ALERT 3D system, to evaluate the specificity of this system, and to decrease the false positive reaction. Each reaction flasks in past five years were processed for bacteria isolation and identification. When the initial cultures were positive, the remaining samples and the corresponding units were recultured if still available. 11395 blood samples were detected. It is worthy of note that the incubator temperature should be stabilized, avoiding fluctuation; when the cultures were alarmed, the reaction flasks showed be kept some hours for further incubation so as to trace a sharply increasing signal to support the judgement of true bacterial growth. The results indicated that 122 samples (1.07%) wee positive at initial culture, out of them 107 samples (88.7%) were found bacterial, and 15 samples (12.3%) were found nothing. The detection curves of positive samples resulted from bacterial growth showed ascent. In conclusion, maintenance of temperature stability and avoidance of temperature fluctuation in incubator could decrease the occurrence of false-positive reaction in detection process. The reaction flasks with positive results at initial culture should be recultured, and whether existence of a sharply ascending logarilhimic growth phase in bacterial growth curve should be further detected, which are helpful to distinguish false-positive reactions from true positive, and thus increase the specificity of the BacT/ALERT system.

  15. A closer look at the effect of preliminary goodness-of-fit testing for normality for the one-sample t-test.

    PubMed

    Rochon, Justine; Kieser, Meinhard

    2011-11-01

    Student's one-sample t-test is a commonly used method when inference about the population mean is made. As advocated in textbooks and articles, the assumption of normality is often checked by a preliminary goodness-of-fit (GOF) test. In a paper recently published by Schucany and Ng it was shown that, for the uniform distribution, screening of samples by a pretest for normality leads to a more conservative conditional Type I error rate than application of the one-sample t-test without preliminary GOF test. In contrast, for the exponential distribution, the conditional level is even more elevated than the Type I error rate of the t-test without pretest. We examine the reasons behind these characteristics. In a simulation study, samples drawn from the exponential, lognormal, uniform, Student's t-distribution with 2 degrees of freedom (t(2) ) and the standard normal distribution that had passed normality screening, as well as the ingredients of the test statistics calculated from these samples, are investigated. For non-normal distributions, we found that preliminary testing for normality may change the distribution of means and standard deviations of the selected samples as well as the correlation between them (if the underlying distribution is non-symmetric), thus leading to altered distributions of the resulting test statistics. It is shown that for skewed distributions the excess in Type I error rate may be even more pronounced when testing one-sided hypotheses. ©2010 The British Psychological Society.

  16. On the occurrence of false positives in tests of migration under an isolation with migration model

    PubMed Central

    Hey, Jody; Chung, Yujin; Sethuraman, Arun

    2015-01-01

    The population genetic study of divergence is often done using a Bayesian genealogy sampler, like those implemented in IMa2 and related programs, and these analyses frequently include a likelihood-ratio test of the null hypothesis of no migration between populations. Cruickshank and Hahn (2014, Molecular Ecology, 23, 3133–3157) recently reported a high rate of false positive test results with IMa2 for data simulated with small numbers of loci under models with no migration and recent splitting times. We confirm these findings and discover that they are caused by a failure of the assumptions underlying likelihood ratio tests that arises when using marginal likelihoods for a subset of model parameters. We also show that for small data sets, with little divergence between samples from two populations, an excellent fit can often be found by a model with a low migration rate and recent splitting time and a model with a high migration rate and a deep splitting time. PMID:26456794

  17. Performance of OncoE6 cervical test with collection methods enabling self-sampling.

    PubMed

    Krings, Amrei; Dückelmann, Anna M; Moser, Lutz; Gollrad, Johannes; Wiegerinck, Maarten; Schweizer, Johannes; Kaufmann, Andreas M

    2018-05-21

    The paradigm shift from cytological screening to Human Papillomavirus (HPV)-based screening for cervical cancer allows the introduction of new technologies in sample collection and diagnostics. The OncoE6™ Cervical Test (OncoE6 Test) is a rapid, easy-to-use lateral flow method detecting HPV16/18 E6 oncoproteins that has proven to detect high-grade cervical lesions with high specificity. If compatible with self-collection samples, this technology might allow for decentralized screening of hard-to-reach populations. For technical validation, cervicovaginal lavages were collected from 20 patients with confirmed HPV16+ or HPV18+ invasive cervical cancer. Cervical smears were collected by polyester-tipped swabs and cytobrushes. All samples were applied to the OncoE6 Test and cytobrush samples additionally genotyped. Lavage, swab, and cytobrush revealed concordant outcome in 18/20 samples. HPV types corresponded with the HPV genotyping by GP5+/6+ PCR analyses. Due to a rare mutation found in the E6 antibody binding site one sample was not detected, another sample had very low cellularity. Overall, vaginal lavages are technically adequate for the OncoE6 Test. Combining self-sampling with oncoprotein rapid testing to detect women with highest risk for severe dysplasia or cancer may allow for secondary cancer prevention in settings where other screening modalities were unsuccessful to date.

  18. A Comparison of Domain Sampling Procedures for Test Construction

    DTIC Science & Technology

    1992-10-01

    B AEROSPACE GROUND EQUIPNENT GENERAL MECHANIC AFSC 454X1 306 KNOWLEDGE TEST AFPT 80-423-205 103 AEROSPACE GOUND EQUIPNENT SPECIALTY (AFS 454Xl) JOB... 454X1 ). The information collected will be used for research purposes only and will have no effect on your career. Test results will be available for...exercise proper towing and positioning procedures, operate two-way radios and clean vehicles. 127 AEROSPACE GROUND EQUIPMENT AFSC 454X1 SELF-RATING FORNS

  19. The Test Validation Summary

    ERIC Educational Resources Information Center

    Frederick, Richard I.; Bowden, Stephen C.

    2009-01-01

    Common rates employed in classificatory testing are the true positive rate (TPR), false positive rate (FPR), positive predictive power (PPP), and negative predictive power (NPP). FPR and TPR are estimated from research samples representing populations to be distinguished by classificatory testing. PPP and NPP are used by clinicians to classify…

  20. A novel method for single sample multi-axial nanoindentation of hydrated heterogeneous tissues based on testing great white shark jaws.

    PubMed

    Ferrara, Toni L; Boughton, Philip; Slavich, Eve; Wroe, Stephen

    2013-01-01

    Nanomechanical testing methods that are suitable for a range of hydrated tissues are crucial for understanding biological systems. Nanoindentation of tissues can provide valuable insights into biology, tissue engineering and biomimetic design. However, testing hydrated biological samples still remains a significant challenge. Shark jaw cartilage is an ideal substrate for developing a method to test hydrated tissues because it is a unique heterogeneous composite of both mineralized (hard) and non-mineralized (soft) layers and possesses a jaw geometry that is challenging to test mechanically. The aim of this study is to develop a novel method for obtaining multidirectional nanomechanical properties for both layers of jaw cartilage from a single sample, taken from the great white shark (Carcharodon carcharias). A method for obtaining multidirectional data from a single sample is necessary for examining tissue mechanics in this shark because it is a protected species and hence samples may be difficult to obtain. Results show that this method maintains hydration of samples that would otherwise rapidly dehydrate. Our study is the first analysis of nanomechanical properties of great white shark jaw cartilage. Variation in nanomechanical properties were detected in different orthogonal directions for both layers of jaw cartilage in this species. The data further suggest that the mineralized layer of shark jaw cartilage is less stiff than previously posited. Our method allows multidirectional nanomechanical properties to be obtained from a single, small, hydrated heterogeneous sample. Our technique is therefore suitable for use when specimens are rare, valuable or limited in quantity, such as samples obtained from endangered species or pathological tissues. We also outline a method for tip-to-optic calibration that facilitates nanoindentation of soft biological tissues. Our technique may help address the critical need for a nanomechanical testing method that is applicable

  1. Inverse sampling regression for pooled data.

    PubMed

    Montesinos-López, Osval A; Montesinos-López, Abelardo; Eskridge, Kent; Crossa, José

    2017-06-01

    Because pools are tested instead of individuals in group testing, this technique is helpful for estimating prevalence in a population or for classifying a large number of individuals into two groups at a low cost. For this reason, group testing is a well-known means of saving costs and producing precise estimates. In this paper, we developed a mixed-effect group testing regression that is useful when the data-collecting process is performed using inverse sampling. This model allows including covariate information at the individual level to incorporate heterogeneity among individuals and identify which covariates are associated with positive individuals. We present an approach to fit this model using maximum likelihood and we performed a simulation study to evaluate the quality of the estimates. Based on the simulation study, we found that the proposed regression method for inverse sampling with group testing produces parameter estimates with low bias when the pre-specified number of positive pools (r) to stop the sampling process is at least 10 and the number of clusters in the sample is also at least 10. We performed an application with real data and we provide an NLMIXED code that researchers can use to implement this method.

  2. The champagne toast position isolates the supraspinatus better than the Jobe test: an electromyographic study of shoulder physical examination tests.

    PubMed

    Chalmers, Peter N; Cvetanovich, Gregory L; Kupfer, Noam; Wimmer, Markus A; Verma, Nikhil N; Cole, Brian J; Romeo, Anthony A; Nicholson, Gregory P

    2016-02-01

    While Jobe's test is widely used, it does not isolate supraspinatus activity. Our purpose was to examine the electromyographic (EMG) activity within the supraspinatus and deltoid with resisted abduction to determine the shoulder position that best isolates the activity of the supraspinatus. We performed EMG analysis of the supraspinatus, anterior head of the deltoid, and middle head of the deltoid in 10 normal volunteers. We measured EMG activity during resisted shoulder abduction in the scapular plane to both manual resistance and a standardized load in varying degrees of abduction and rotation. To determine which position best isolates supraspinatus activity, the ratio of supraspinatus to deltoid activity (S:D) was calculated for each position. Results were analyzed with a repeated-measures analysis of variance with Bonferroni correction. The posterior deltoid was excluded as it serves mostly to extend and externally rotate. Our study confirmed Jobe's findings of maximal supraspinatus activity at 90° of abduction. However, decreasing abduction significantly increased S:D for both resisted manual testing and testing against a standardized load (P = .002 and .001, respectively). The greatest S:D ratio (4.6 ± 3.4 for standardized load testing) was seen at the "champagne toast" position, i.e., 30° of abduction, mild external rotation, 30° of flexion, and 90° of elbow flexion. The smallest ratio (0.8 ± 0.6) was seen at Jobe's position. Testing of abduction strength in the champagne toast position, i.e., 30° of abduction, mild external rotation, and 30° of flexion, better isolates the activity of the supraspinatus from the deltoid than Jobe's "empty can" position. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. Impact of deploying multiple point-of-care tests with a 'sample first' approach on a sexual health clinical care pathway. A service evaluation.

    PubMed

    Harding-Esch, Emma M; Nori, Achyuta V; Hegazi, Aseel; Pond, Marcus J; Okolo, Olanike; Nardone, Anthony; Lowndes, Catherine M; Hay, Phillip; Sadiq, S Tariq

    2017-09-01

    To assess clinical service value of STI point-of-care test (POCT) use in a 'sample first' clinical pathway (patients providing samples on arrival at clinic, before clinician consultation). Specific outcomes were: patient acceptability; whether a rapid nucleic acid amplification test (NAAT) for Chlamydia trachomatis/Neisseria gonorrhoeae (CT/NG) could be used as a POCT in practice; feasibility of non-NAAT POCT implementation for Trichomonas vaginalis (TV) and bacterial vaginosis (BV); impact on patient diagnosis and treatment. Service evaluation in a south London sexual health clinic. Symptomatic female and male patients and sexual contacts of CT/NG-positive individuals provided samples for diagnostic testing on clinic arrival, prior to clinical consultation. Tests included routine culture and microscopy; CT/NG (GeneXpert) NAAT; non-NAAT POCTs for TV and BV. All 70 (35 males, 35 females) patients approached participated. The 'sample first' pathway was acceptable, with >90% reporting they were happy to give samples on arrival and receive results in the same visit. Non-NAAT POCT results were available for all patients prior to leaving clinic; rapid CT/NG results were available for only 21.4% (15/70; 5 males, 10 females) of patients prior to leaving clinic. Known negative CT/NG results led to two females avoiding presumptive treatment, and one male receiving treatment directed at possible Mycoplasma genitalium infection causing non-gonococcal urethritis. Non-NAAT POCTs detected more positives than routine microscopy (TV 3 vs 2; BV 24 vs 7), resulting in more patients receiving treatment. A 'sample first' clinical pathway to enable multiple POCT use was acceptable to patients and feasible in a busy sexual health clinic, but rapid CT/NG processing time was too long to enable POCT use. There is need for further development to improve test processing times to enable POC use of rapid NAATs. Published by the BMJ Publishing Group Limited. For permission to use (where not

  4. Further examination of embedded performance validity indicators for the Conners' Continuous Performance Test and Brief Test of Attention in a large outpatient clinical sample.

    PubMed

    Sharland, Michael J; Waring, Stephen C; Johnson, Brian P; Taran, Allise M; Rusin, Travis A; Pattock, Andrew M; Palcher, Jeanette A

    2018-01-01

    Assessing test performance validity is a standard clinical practice and although studies have examined the utility of cognitive/memory measures, few have examined attention measures as indicators of performance validity beyond the Reliable Digit Span. The current study further investigates the classification probability of embedded Performance Validity Tests (PVTs) within the Brief Test of Attention (BTA) and the Conners' Continuous Performance Test (CPT-II), in a large clinical sample. This was a retrospective study of 615 patients consecutively referred for comprehensive outpatient neuropsychological evaluation. Non-credible performance was defined two ways: failure on one or more PVTs and failure on two or more PVTs. Classification probability of the BTA and CPT-II into non-credible groups was assessed. Sensitivity, specificity, positive predictive value, and negative predictive value were derived to identify clinically relevant cut-off scores. When using failure on two or more PVTs as the indicator for non-credible responding compared to failure on one or more PVTs, highest classification probability, or area under the curve (AUC), was achieved by the BTA (AUC = .87 vs. .79). CPT-II Omission, Commission, and Total Errors exhibited higher classification probability as well. Overall, these findings corroborate previous findings, extending them to a large clinical sample. BTA and CPT-II are useful embedded performance validity indicators within a clinical battery but should not be used in isolation without other performance validity indicators.

  5. Prevalences of positive skin test responses to 10 common allergens in the US population: results from the third National Health and Nutrition Examination Survey.

    PubMed

    Arbes, Samuel J; Gergen, Peter J; Elliott, Leslie; Zeldin, Darryl C

    2005-08-01

    Allergy skin tests were administered in the second and third National Health and Nutrition Examination Surveys (NHANES II and III) conducted in the United States from 1976 through 1980 and 1988 through 1994, respectively. This study estimated positive skin test response rates in NHANES III and identified predictors of one or more positive test responses. Comparisons with NHANES II were also made. In NHANES III, 10 allergens and 2 controls were tested in all subjects aged 6 to 19 years and a random half-sample of subjects aged 20 to 59 years. A wheal-based definition of a positive test response was used. In NHANES III, 54.3% of the population had positive test responses to 1 or more allergens. Prevalences were 27.5% for dust mite, 26.9% for perennial rye, 26.2% for short ragweed, 26.1% for German cockroach, 18.1% for Bermuda grass, 17.0% for cat, 15.2% for Russian thistle, 13.2% for white oak, 12.9% for Alternaria alternata, and 8.6% for peanut. Among those with positive test responses, the median number of positive responses was 3.0. Adjusted odds of a positive test response were higher for the following variables: age of 20 to 29 years, male sex, minority race, western region, old homes, and lower serum cotinine levels. For the 6 allergens common to NHANES II and III, prevalences were 2.1 to 5.5 times higher in NHANES III. The majority of the US population represented in NHANES III was sensitized to 1 or more allergens. Whether the higher prevalences observed in NHANES III reflect true changes in prevalence or methodological differences between the surveys cannot be determined with certainty.

  6. Screening for tinea unguium by Dermatophyte Test Strip.

    PubMed

    Tsunemi, Y; Takehara, K; Miura, Y; Nakagami, G; Sanada, H; Kawashima, M

    2014-02-01

    The direct microscopy, fungal culture and histopathology that are necessary for the definitive diagnosis of tinea unguium are disadvantageous in that detection sensitivity is affected by the level of skill of the person who performs the testing, and the procedures take a long time. The Dermatophyte Test Strip, which was developed recently, can simply and easily detect filamentous fungi in samples in a short time, and there are expectations for its use as a method for tinea unguium screening. With this in mind, we examined the detection capacity of the Dermatophyte Test Strip for tinea unguium. The presence or absence of fungal elements was judged by direct microscopy and Dermatophyte Test Strip in 165 nail samples obtained from residents in nursing homes for the elderly. Moreover, the minimum sample amount required for positive determination was estimated using 32 samples that showed positive results by Dermatophyte Test Strip. The Dermatophyte Test Strip showed 98% sensitivity, 78% specificity, 84·8% positive predictive value, 97% negative predictive value and a positive and negative concordance rate of 89·1%. The minimum sample amount required for positive determination was 0·002-0·722 mg. The Dermatophyte Test Strip showed very high sensitivity and negative predictive value, and was considered a potentially useful method for tinea unguium screening. Positive determination was considered to be possible with a sample amount of about 1 mg. © 2013 British Association of Dermatologists.

  7. Women's views on human papillomavirus self-sampling: focus groups to assess acceptability, invitation letters and a test kit in the Australian setting.

    PubMed

    Sultana, Farhana; Mullins, Robyn; Murphy, Michael; English, Dallas R; Simpson, Julie A; Drennan, Kelly T; Heley, Stella; Wrede, C David; Brotherton, Julia M L; Saville, Marion; Gertig, Dorota M

    2015-08-01

    Background The study evaluated acceptability, invitation letters and the test kit for a trial of human papillomavirus (HPV) self-sampling among never- and under-screened women in Australia. Victorian women, 30-69 years, who had never had a Pap test or were overdue for one, participated. Four focus groups including eight to nine participants segmented by age (30-49 and 50-69 years) and screening history (never- and under-screened) were conducted in August 2013. Discussions were recorded and transcribed verbatim and data analysed using thematic content analysis. The response to the concept of HPV self-sampling was positive. Decision-making was largely influenced by the content of a pre-invitation letter. Appealing features of self-sampling were cost (free), convenience (home-based) and anticipated less discomfort (with a swab) than a Pap test. Small kits that fit in mailboxes were preferred over post office parcel collection. The perceived barriers include concerns about test accuracy and lack of confidence that a home-based test would give the same results as a physician administered test. Women wanted information on the timing of receipt of the results and information about the organisation providing the test. HPV self-sampling is a possible alternative for Australian women who are reluctant to have a Pap test and may increase the likelihood of participation in cervical cancer screening if women's concerns about it can be addressed. The findings of this study are relevant for researchers, policymakers and practitioners implementing self-sampling for under-screened women as part of cervical screening programs.

  8. [The comparative study of specificity of test-systems in diagnostic of HIV-infection on categories of samples of blood serum of pregnant women].

    PubMed

    Sharipova, I N; Khodak, N M; Puzirev, V F; Burkov, A N; Ulanova, T I

    2015-03-01

    The detection of false positive serological reactions (FPSR) on HIV-infection under screening examination of pregnant women is an actual problem of practical health care. The original observations testify that under analysis of the same samples of blood serum of pregnant women using screening immune enzyme test-systems of various manufacturers the unmatched data concerning FPSR can be obtained. The purpose of this study was to implement comparative evaluation of specificity of immune enzyme test-systems of three different manufacturers: "DS-IFA-HIV-AGAT-SCREEN" ("Diagnostic Systems"), "Genscreen Ultra HIV Ag-Ab" "Bio Rad" France) and "The CombiBest HIV-1,2 AG/AT" ("Vector-Best" Novosibirsk). The sampling of 440 samples of blood serums of pregnant women from various medical institutions of Nizhnii Novgorod was analyzed. The results of the study demonstrated that FPSR were detected in all test-systems and at that spectrum of samples differed. The identical specificity of compared test-systems amounted to 98.64%. The alternative approach to FPSR to HIV issue under screening examinations of pregnant women was proposed. The proposed mode consisted of consistent application of two test-systems of fourth generation with different format of setup of reaction.

  9. Application of drilling, coring, and sampling techniques to test holes and wells

    USGS Publications Warehouse

    Shuter, Eugene; Teasdale, Warren E.

    1989-01-01

    The purpose of this manual is to provide ground-water hydrologists with a working knowledge of the techniques of test drilling, auger drilling, coring and sampling, and the related drilling and sampling equipment. For the most part, the techniques discussed deal with drilling, sampling, and completion of test holes in unconsolidated sediments because a hydrologist is interested primarily in shallow-aquifer data in this type of lithology. Successful drilling and coring of these materials usually is difficult, and published research information on the subject is not readily available. The authors emphasize in-situ sampling of unconsolidated sediments to obtain virtually undisturbed samples. Particular attention is given to auger drilling and hydraulic-rotary methods of drilling because these are the principal means of test drilling performed by the U.S. Geological Survey during hydrologic studies. Techniques for sampling areas contaminated by solid or liquid waste are discussed. Basic concepts of well development and a detailed discussion of drilling muds, as related to hole conditioning, also are included in the report. The information contained in this manual is intended to help ground-water hydrologists obtain useful subsurface data and samples from their drilling programs.

  10. The BIOSAFEPAPER project for in vitro toxicity assessments: preparation, detailed chemical characterisation and testing of extracts from paper and board samples.

    PubMed

    Bradley, E L; Honkalampi-Hämäläinen, U; Weber, A; Andersson, M A; Bertaud, F; Castle, L; Dahlman, O; Hakulinen, P; Hoornstra, D; Lhuguenot, J-C; Mäki-Paakkanen, J; Salkinoja-Salonen, M; Speck, D R; Severin, I; Stammati, A; Turco, L; Zucco, F; von Wright, A

    2008-07-01

    Nineteen food contact papers and boards and one non-food contact board were extracted following test protocols developed within European Union funded project BIOSAFEPAPER. The extraction media were either hot or cold water, 95% ethanol or Tenax, according to the end use of the sample. The extractable dry matter content of the samples varied from 1200 to 11,800 mg/kg (0.8-35.5 mg/dm2). According to GC-MS the main substances extracted into water were pulp-derived natural products such as fatty acids, resin acids, natural wood sterols and alkanols. Substances extracted into ethanol particularly, were diisopropylnaphthalenes, alkanes and phthalic acid esters. The non-food contact board showed the greatest number and highest concentrations of GC-MS detectable compounds. The extracts were subjected to a battery of in vitro toxicity tests measuring both acute and sublethal cytotoxicity and genotoxic effects. None of the water or Tenax extracts was positive in cytotoxicity or genotoxicity assays. The ethanol extract of the non-food contact board gave a positive response in the genotoxicity assays, and all four ethanol extracts gave positive response(s) in the cytotoxicity assays to some extent. These responses could not be pinpointed to any specific compound, although there appeared a correlation between the total amount of extractables and toxicity.

  11. Detection test of wireless network signal strength and GPS positioning signal in underground pipeline

    NASA Astrophysics Data System (ADS)

    Li, Li; Zhang, Yunwei; Chen, Ling

    2018-03-01

    In order to solve the problem of selecting positioning technology for inspection robot in underground pipeline environment, the wireless network signal strength and GPS positioning signal testing are carried out in the actual underground pipeline environment. Firstly, the strength variation of the 3G wireless network signal and Wi-Fi wireless signal provided by China Telecom and China Unicom ground base stations are tested, and the attenuation law of these wireless signals along the pipeline is analyzed quantitatively and described. Then, the receiving data of the GPS satellite signal in the pipeline are tested, and the attenuation of GPS satellite signal under underground pipeline is analyzed. The testing results may be reference for other related research which need to consider positioning in pipeline.

  12. Principles of Work Sample Testing. 4. Generalizability

    DTIC Science & Technology

    1979-04-01

    ARI TECHNICAL REPORT TR-79-A11 Principles of Work Sample Testing: IV. Generallzability , by ,lobert M. Guion Gail H. Ironson BOWLING GREEN STATE...UNIVERSITY Bowling Green , Ohio 43403 April 1979 or -Contract DAHC 19-77-C-0007 d CD, LUa.J Prepared for -_J ;=U.S. ARMY RESEARCH INSTITUTE for the...ORGANIZATION NAME AND ADDRESS 10. PROG RAM ELEMENT. PROJECT, TASK A REA & WORK UNIT NUMBERS Bowling Green State University __ Bowling Green , Ohio 43403

  13. Field tests of a handheld laser communications/position-finding binocular system

    NASA Astrophysics Data System (ADS)

    Chan, Victor J.; Rivers, Michael D.; Harris, Amy L.

    1998-01-01

    Lasers provide a means for transmitting larger quantities of data at higher rates than conventional radio frequency devices and can be utilized during radio silent operations on the battle field. A forward scout needs to be able to observe the positions of various targets and relay that information back to a tactical operations command center in a covert manner. The BiCom device built by Trex Communications provides laser ranging, azimuth and elevation angle to a target, GPS position information, data storage and transmit capability, and full duplex audio transmission capability, all in a 3 kg hand held package. The communication channel utilizes an eye safe lasercom transceiver for covert voice or data transfer at 100 kbps at distances of up to 5 km. The information gathered electronically by the unit is sufficient to calculate the actual GPS positions or military grid coordinates of the observed targets. Several dozen targets can be stored in memory for later transmission via lasercom. Field tests were conducted by US Army personnel to evaluate these units and compare the results with conventional means of target position determination and data transfer. A description of the system and results of these tests are presented.

  14. Skin irritability to sodium lauryl sulfate is associated with increased positive patch test reactions.

    PubMed

    Schwitulla, J; Brasch, J; Löffler, H; Schnuch, A; Geier, J; Uter, W

    2014-07-01

    As previous observations have indicated an inter-relationship between irritant and allergic skin reactions we analysed data of synchronous allergen and sodium lauryl sulfate (SLS) patch tests in terms of a relationship between SLS responsiveness and allergic patch test reactions. To analyse differences in terms of allergen-specific and overall reaction profiles between patients with vs. those without an irritant reaction to SLS. Clinical data of 26 879 patients patch tested from 2008 to 2011 by members of the Information Network of Departments of Dermatology were analysed. After descriptive analyses, including the MOAHLFA index, the positivity ratio and the reaction index, a negative binomial hurdle model was adopted to investigate the correlation between SLS reactivity and positive patch test reactions. Men, patients aged ≥ 40 years and patients with an occupational dermatitis background were over-represented in the SLS-reactive group. Patients with an irritant reaction to SLS showed a higher proportion of weak positive reactions, as well as more questionable and irritant reactions to contact allergens than patients not reactive to SLS. The risk of an additional positive patch test reaction increased by 22% for SLS-reactive patients compared with those who were SLS negative. The marked association between SLS reactivity and the number of positive reactions in patch test patients may be due to nonspecific increased skin reactivity at the moment of patch testing only. However, increased SLS reactivity could also be due to longer-lasting enhanced skin irritability, which may have promoted (poly-)sensitization. Further studies, for example with longitudinal data on patients repeatedly patch tested with SLS and contact allergens, are necessary. © 2014 British Association of Dermatologists.

  15. POREWATER CHEMISTRY: EFFECTS OF SAMPLING, STORAGE, HANDLING, AND TOXICITY TESTING

    EPA Science Inventory

    As a general principle, it is nearly impossible to remove a porewater sample from sediment, use it in a toxicity testing vessel with test organisms, and prevent changes in the chemistry of the natural and anthropogenic organic and inorganic constituents. The degree of change in t...

  16. Synthesizing Information from Language Samples and Standardized Tests in School-Age Bilingual Assessment

    ERIC Educational Resources Information Center

    Ebert, Kerry Danahy; Pham, Giang

    2017-01-01

    Purpose: Although language samples and standardized tests are regularly used in assessment, few studies provide clinical guidance on how to synthesize information from these testing tools. This study extends previous work on the relations between tests and language samples to a new population--school-age bilingual speakers with primary language…

  17. Design, building and test of one prototype and four final position sensor assemblies: Hall effect position sensors

    NASA Technical Reports Server (NTRS)

    1976-01-01

    This report covers the development of a three channel Hall effect position sensing system for the commutation of a three phase dc torquer motor. The effort consisted of the evaluation, modification and re-packaging of a commercial position sensor and the design of a target configuration unique to this application. The resulting design meets the contract requirements and, furthermore, the test results indicate not only the practicality and versatility of the design, but also that there may be higher limits of resolution and accuracy achievable.

  18. Analytic and Clinical Performance of cobas HPV Testing in Anal Specimens from HIV-Positive Men Who Have Sex with Men

    PubMed Central

    Follansbee, Stephen; Borgonovo, Sylvia; Tokugawa, Diane; Sahasrabuddhe, Vikrant V.; Chen, Jie; Lorey, Thomas S.; Gage, Julia C.; Fetterman, Barbara; Boyle, Sean; Sadorra, Mark; Tang, Scott Dahai; Darragh, Teresa M.; Castle, Philip E.

    2014-01-01

    Anal human papillomavirus (HPV) infections are common, and the incidence of anal cancer is high in HIV-infected men who have sex with men (MSM). To evaluate the performance of HPV assays in anal samples, we compared the cobas HPV test (cobas) to the Roche Linear Array HPV genotyping assay (LA) and cytology in HIV-infected MSM. Cytology and cobas and LA HPV testing were conducted for 342 subjects. We calculated agreement between the HPV assays and the clinical performance of HPV testing and HPV genotyping alone and in combination with anal cytology. We observed high agreement between cobas and LA, with cobas more likely than LA to show positive results for HPV16, HPV18, and other carcinogenic types. Specimens testing positive in cobas but not in LA were more likely to be positive for other markers of HPV-related disease compared to those testing negative in both assays, suggesting that at least some of these were true positives for HPV. cobas and LA showed high sensitivities but low specificities for the detection of anal intraepithelial neoplasia grade 2/3 (AIN2/3) in this population (100% sensitivity and 26% specificity for cobas versus 98.4% sensitivity and 28.9% specificity for LA). A combination of anal cytology and HPV genotyping provided the highest accuracy for detecting anal precancer. A higher HPV load was associated with a higher risk of AIN2/3 with HPV16 (Ptrend < 0.001), HPV18 (Ptrend = 0.07), and other carcinogenic types (Ptrend < 0.001). We demonstrate that cobas can be used for HPV detection in anal cytology specimens. Additional tests are necessary to identify men at the highest risk of anal cancer among those infected with high-risk HPV. PMID:24899025

  19. Analytic and clinical performance of cobas HPV testing in anal specimens from HIV-positive men who have sex with men.

    PubMed

    Wentzensen, Nicolas; Follansbee, Stephen; Borgonovo, Sylvia; Tokugawa, Diane; Sahasrabuddhe, Vikrant V; Chen, Jie; Lorey, Thomas S; Gage, Julia C; Fetterman, Barbara; Boyle, Sean; Sadorra, Mark; Tang, Scott Dahai; Darragh, Teresa M; Castle, Philip E

    2014-08-01

    Anal human papillomavirus (HPV) infections are common, and the incidence of anal cancer is high in HIV-infected men who have sex with men (MSM). To evaluate the performance of HPV assays in anal samples, we compared the cobas HPV test (cobas) to the Roche Linear Array HPV genotyping assay (LA) and cytology in HIV-infected MSM. Cytology and cobas and LA HPV testing were conducted for 342 subjects. We calculated agreement between the HPV assays and the clinical performance of HPV testing and HPV genotyping alone and in combination with anal cytology. We observed high agreement between cobas and LA, with cobas more likely than LA to show positive results for HPV16, HPV18, and other carcinogenic types. Specimens testing positive in cobas but not in LA were more likely to be positive for other markers of HPV-related disease compared to those testing negative in both assays, suggesting that at least some of these were true positives for HPV. cobas and LA showed high sensitivities but low specificities for the detection of anal intraepithelial neoplasia grade 2/3 (AIN2/3) in this population (100% sensitivity and 26% specificity for cobas versus 98.4% sensitivity and 28.9% specificity for LA). A combination of anal cytology and HPV genotyping provided the highest accuracy for detecting anal precancer. A higher HPV load was associated with a higher risk of AIN2/3 with HPV16 (P(trend) < 0.001), HPV18 (P(trend) = 0.07), and other carcinogenic types (P(trend) < 0.001). We demonstrate that cobas can be used for HPV detection in anal cytology specimens. Additional tests are necessary to identify men at the highest risk of anal cancer among those infected with high-risk HPV. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  20. Evaluating the case-positive, control test-negative study design for influenza vaccine effectiveness for the frailty bias.

    PubMed

    Talbot, H Keipp; Nian, Hui; Chen, Qingxia; Zhu, Yuwei; Edwards, Kathryn M; Griffin, Marie R

    2016-04-04

    Previous influenza vaccine effectiveness studies were criticized for their failure to control for frailty. This study was designed to see if the test-negative study design overcomes this bias. Adults ≥ 50 years of age with respiratory symptoms were enrolled from November 2006 through May 2012 during the influenza season (excluding the 2009-2010 H1N1 pandemic season) to perform yearly test-negative control influenza vaccine effectiveness studies in Nashville, TN. At enrollment, both a nasal and throat swab sample were obtained and tested for influenza by RT-PCR. Frailty was calculated using a modified Rockwood Index that included 60 variables ascertained in a retrospective chart review giving a score of 0 to 1. Subjects were divided into three strata: non frail (≤ 0.08), pre-frail (> 0.08 to < 0.25), and frail (≥ 0.25). Vaccine effectiveness was calculated using the formula [1-adjusted odds ratio (OR)] × 100%. Adjusted ORs for individual years and all years combined were estimated by penalized multivariable logistic regression. Of 1023 hospitalized adults enrolled, 866 (84.7%) participants had complete immunization status, molecular influenza testing and covariates to calculate frailty. There were 83 influenza-positive cases and 783 test-negative controls overall, who were 74% white, 25% black, and 59% female. The median frailty index was 0.167 (Interquartile: 0.117, 0.267). The frailty index was 0.167 (0.100, 0.233) for the influenza positive cases compared to 0.183 (0.133, 0.267) for influenza negative controls (p = 0.07). Vaccine effectiveness estimates were 55.2% (95%CI: 30.5, 74.2), 60.4% (95%CI: 29.5, 74.4), and 54.3% (95%CI: 28.8, 74.0) without the frailty variable, including frailty as a continuous variable, and including frailty as a categorical variable, respectively. Using the case positive test negative study design to assess vaccine effectiveness, our measure of frailty was not a significant confounder as inclusion of this measure did not

  1. Coaxial test fixture

    DOEpatents

    Praeg, Walter F.

    1986-01-01

    An assembly is provided for testing one or more contact material samples in a vacuum environment. The samples are positioned as an inner conductive cylinder assembly which is mounted for reciprocal vertical motion as well as deflection from a vertical axis. An outer conductive cylinder is coaxially positioned around the inner cylinder and test specimen to provide a vacuum enclosure therefor. A power source needed to drive test currents through the test specimens is connected to the bottom of each conductive cylinder, through two specially formed conductive plates. The plates are similar in form, having a plurality of equal resistance current paths connecting the power source to a central connecting ring. The connecting rings are secured to the bottom of the inner conductive assembly and the outer cylinder, respectively. A hydraulic actuator is also connected to the bottom of the inner conductor assembly to adjust the pressure applied to the test specimens during testing. The test assembly controls magnetic forces such that the current distribution through the test samples is symmetrical and that contact pressure is not reduced or otherwise disturbed.

  2. DATA QUALITY OBJECTIVES FOR SELECTING WASTE SAMPLES FOR THE BENCH STEAM REFORMER TEST

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BANNING DL

    2010-08-03

    This document describes the data quality objectives to select archived samples located at the 222-S Laboratory for Fluid Bed Steam Reformer testing. The type, quantity and quality of the data required to select the samples for Fluid Bed Steam Reformer testing are discussed. In order to maximize the efficiency and minimize the time to treat Hanford tank waste in the Waste Treatment and Immobilization Plant, additional treatment processes may be required. One of the potential treatment processes is the fluid bed steam reformer (FBSR). A determination of the adequacy of the FBSR process to treat Hanford tank waste is required.more » The initial step in determining the adequacy of the FBSR process is to select archived waste samples from the 222-S Laboratory that will be used to test the FBSR process. Analyses of the selected samples will be required to confirm the samples meet the testing criteria.« less

  3. Online Sex Partner Meeting Venues as a Risk Factor for Testing HIV Positive Among a Community-Based Sample of Black Men Who Have Sex With Men.

    PubMed

    Eaton, Lisa A; Maksut, Jessica L; Gamarel, Kristi E; Siembida, Elizabeth J; Driffin, Daniel D; Baldwin, Robert

    2016-06-01

    In the United States, black men who have sex with men (BMSM) are disproportionately affected by the HIV epidemic. The elevated estimates of HIV among BMSM suggest that to slow rates of HIV infections, a range of factors that may contribute to transmission must be researched. Use of online venues for seeking out sex partners is one such area that may further advance our understanding of risks for HIV among BMSM. Black men who have sex with men residing in Atlanta, GA, reporting HIV-negative/unknown status completed survey assessments and HIV antibody testing. Logistic regression using generalized linear modeling was used to conduct both bivariate and multivariable analyses of psychosocial variables-that is, substance use, sexually transmitted infection symptoms/diagnoses, sexual risk behavior, online sex partner meeting, and HIV test results. Two hundred thirty-two BMSM tested HIV negative and 39 BMSM tested HIV positive (14% new diagnoses). Reporting symptoms of a rectal sexually transmitted infection (odds ratio, 4.28; 95% confidence interval, 1.06-15.41) and use of sexual networking apps (odds ratio, 2.15; 95% confidence interval, 1.06-4.36) were both associated with testing HIV positive in a multivariable analysis. The use of sexual networking apps is associated with risks for HIV infection above and beyond what is captured by sexual risk behavior alone. Evaluating how sexual networking apps affect sexual networks and social norms regarding sexual risk taking and HIV transmission is an important and novel area for HIV prevention and intervention development.

  4. A Recombinant Positive Control for Serology Diagnostic Tests Supporting Elimination of Onchocerca volvulus.

    PubMed

    Golden, Allison; Stevens, Eric J; Yokobe, Lindsay; Faulx, Dunia; Kalnoky, Michael; Peck, Roger; Valdez, Melissa; Steel, Cathy; Karabou, Potochoziou; Banla, Méba; Soboslay, Peter T; Adade, Kangi; Tekle, Afework H; Cama, Vitaliano A; Fischer, Peter U; Nutman, Thomas B; Unnasch, Thomas R; de los Santos, Tala; Domingo, Gonzalo J

    2016-01-01

    Serological assays for human IgG4 to the Onchocerca volvulus antigen Ov16 have been used to confirm elimination of onchocerciasis in much of the Americas and parts of Africa. A standardized source of positive control antibody (human anti-Ov16 IgG4) will ensure the quality of surveillance data using these tests. A recombinant human IgG4 antibody to Ov16 was identified by screening against a synthetic human Fab phage display library and converted into human IgG4. This antibody was developed into different positive control formulations for enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT) platforms. Variation in ELISA results and utility as a positive control of the antibody were assessed from multiple laboratories. Temperature and humidity conditions were collected across seven surveillance activities from 2011-2014 to inform stability requirements for RDTs and positive controls. The feasibility of the dried positive control for RDT was evaluated during onchocerciasis surveillance activity in Togo, in 2014. When the anti-Ov16 IgG4 antibody was used as a standard dilution in horseradish peroxidase (HRP) and alkaline phosphatase (AP) ELISAs, the detection limits were approximately 1ng/mL by HRP ELISA and 10ng/mL by AP ELISA. Positive control dilutions and spiked dried blood spots (DBS) produced similar ELISA results. Used as a simple plate normalization control, the positive control antibody may improve ELISA data comparison in the context of inter-laboratory variation. The aggregate temperature and humidity monitor data informed temperature parameters under which the dried positive control was tested and are applicable inputs for testing of diagnostics tools intended for sub-Saharan Africa. As a packaged positive control for Ov16 RDTs, stability of the antibody was demonstrated for over six months at relevant temperatures in the laboratory and for over 15 weeks under field conditions. The recombinant human anti-Ov16 IgG4 antibody-based positive

  5. Using the Student's "t"-Test with Extremely Small Sample Sizes

    ERIC Educational Resources Information Center

    de Winter, J. C .F.

    2013-01-01

    Researchers occasionally have to work with an extremely small sample size, defined herein as "N" less than or equal to 5. Some methodologists have cautioned against using the "t"-test when the sample size is extremely small, whereas others have suggested that using the "t"-test is feasible in such a case. The present…

  6. Acceptance sampling for attributes via hypothesis testing and the hypergeometric distribution

    NASA Astrophysics Data System (ADS)

    Samohyl, Robert Wayne

    2017-10-01

    This paper questions some aspects of attribute acceptance sampling in light of the original concepts of hypothesis testing from Neyman and Pearson (NP). Attribute acceptance sampling in industry, as developed by Dodge and Romig (DR), generally follows the international standards of ISO 2859, and similarly the Brazilian standards NBR 5425 to NBR 5427 and the United States Standards ANSI/ASQC Z1.4. The paper evaluates and extends the area of acceptance sampling in two directions. First, by suggesting the use of the hypergeometric distribution to calculate the parameters of sampling plans avoiding the unnecessary use of approximations such as the binomial or Poisson distributions. We show that, under usual conditions, discrepancies can be large. The conclusion is that the hypergeometric distribution, ubiquitously available in commonly used software, is more appropriate than other distributions for acceptance sampling. Second, and more importantly, we elaborate the theory of acceptance sampling in terms of hypothesis testing rigorously following the original concepts of NP. By offering a common theoretical structure, hypothesis testing from NP can produce a better understanding of applications even beyond the usual areas of industry and commerce such as public health and political polling. With the new procedures, both sample size and sample error can be reduced. What is unclear in traditional acceptance sampling is the necessity of linking the acceptable quality limit (AQL) exclusively to the producer and the lot quality percent defective (LTPD) exclusively to the consumer. In reality, the consumer should also be preoccupied with a value of AQL, as should the producer with LTPD. Furthermore, we can also question why type I error is always uniquely associated with the producer as producer risk, and likewise, the same question arises with consumer risk which is necessarily associated with type II error. The resolution of these questions is new to the literature. The

  7. Optimal approaches for inline sampling of organisms in ballast water: L-shaped vs. Straight sample probes

    NASA Astrophysics Data System (ADS)

    Wier, Timothy P.; Moser, Cameron S.; Grant, Jonathan F.; Riley, Scott C.; Robbins-Wamsley, Stephanie H.; First, Matthew R.; Drake, Lisa A.

    2017-10-01

    Both L-shaped ("L") and straight ("Straight") sample probes have been used to collect water samples from a main ballast line in land-based or shipboard verification testing of ballast water management systems (BWMS). A series of experiments was conducted to quantify and compare the sampling efficiencies of L and Straight sample probes. The findings from this research-that both L and Straight probes sample organisms with similar efficiencies-permit increased flexibility for positioning sample probes aboard ships.

  8. Measuring use of positive thinking skills: psychometric testing of a new scale.

    PubMed

    Bekhet, Abir K; Zauszniewski, Jaclene A

    2013-09-01

    Positive thinking interventions improve adaptive functioning and quality of life in many populations. However, no direct measure of positive thinking skills taught during intervention exists. This psychometric study of a convenience sample of 109 autism spectrum disorder (ASD) caregivers examined a new eight-item Positive Thinking Skills Scale (PTSS), which measures the frequency of use of positive thinking skills. The PTSS was found to be internally consistent (α = .90). Construct validity was supported by significant correlations (p < .01) with positive cognitions (r = .53), resourcefulness (r = .63), depression (r = -.45), and general well-being (r = .40). The findings support use of the PTSS as a potential indicator of intervention fidelity among ASD caregivers. However, because it is not specific for ASD caregivers, the PTSS has the potential for wider usage in other populations for whom the identification of specific positive thinking skills could provide direction for future intervention.

  9. Hepatitis C virus genotyping of organ donor samples to aid in transplantation of HCV-positive organs.

    PubMed

    Gentile, Caren; Van Deerlin, Vivianna M; Goldberg, David S; Reese, Peter P; Hasz, Richard D; Abt, Peter; Blumberg, Emily; Farooqi, Midhat S

    2018-02-01

    Given the availability of new highly efficacious anti-HCV therapies, some clinicians have advocated for wider use of kidneys from hepatitis C virus-positive (HCV+) donors, including transplanting them into HCV-negative recipients. As treatment regimens for HCV are commonly guided by genotype, pretransplant HCV genotyping of tissue donors would be beneficial. To our knowledge, donor HCV genotyping has never been reported. We retrieved archived frozen plasma samples for 17 previous organ donors through a local organ procurement organization. We performed HCV genotyping using the eSensor HCVg Direct Test (GenMark Diagnostics) and also by Sanger sequencing, for confirmation (Retrogen). In addition, viral loads were measured using the COBAS AmpliPrep/TaqMan system (Roche Diagnostics). We found that most of the samples (n = 14) were HCV Genotype 1a with the remainder being Genotype 2b (n = 1) or Genotype 3 (n = 2). All genotyping results were concordant with Sanger sequencing. The average HCV viral load in the sample group was ~ 1.6 million IU/mL (range: ~16 000 IU/mL to 7 million IU/mL). We demonstrate that viral RNA from organ donor plasma can be successfully genotyped for HCV. This ability suggests that transplantation of HCV+ kidneys into HCV-negative recipients, followed by genotype-guided antiviral therapy, could be feasible. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. 75 FR 16874 - Market Test of “Samples Co-Op Box” Experimental Product

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-02

    ... POSTAL SERVICE Market Test of ``Samples Co-Op Box'' Experimental Product AGENCY: Postal Service TM . ACTION: Notice. SUMMARY: The Postal Service gives notice of a market test of an experimental product in... pursuant to 39 U.S.C. 3641(c)(1) that it will begin a market test of its ``Samples Co-Op Box'' experimental...

  11. Subtypes of depressive symptoms and inflammatory biomarkers: An exploratory study on a sample of HIV-positive patients

    PubMed Central

    Pala, A. Norcini; Steca, P.; Bagrodia, R.; Helpman, L.; Colangeli, V.; Viale, P.; Wainberg, M.L.

    2017-01-01

    Depressive symptoms cause major impairment and may accelerate HIV progression despite the use of antiretroviral medication. The somatic symptoms criteria for HIV infection and depression partially overlap, which can make differential diagnosis challenging. Because of chronic inflammation caused by HIV infection, HIV-positive patients may develop somatic and affective-cognitive symptoms of depression. Inflammation-related depression is primarily characterized with severe somatic symptoms such as fatigue and sleep disturbance. This study sought to explore the patterns of somatic and cognitive-affective depressive symptoms that characterize HIV-positive patients. Our specific aims were (1) to identify subtypes of depressive symptoms in a sample of HIV-positive patients; and (2) to test the subtypes’ difference on inflammatory and HIV disease progression biomarkers. HIV-positive men and women (N = 102) with and without depressive symptoms were randomly selected from an Italian HIV clinic. Depressive symptoms (PHQ-9), viral load (VL), CD4+, Il-6, TNF-α, and monocytes were assessed. The three subtypes formed using Latent Class Analysis (LCA) identified patients with (1) severe cognitive-affective and somatic depressive symptoms; (2) severe/moderate somatic symptoms; and (3) absent or low depressive symptoms. The subtype with severe/moderate somatic symptoms was characterized with elevated levels of Il-6 and monocytes. No difference on HIV progression biomarkers was found. The subtypes of depressive symptoms might help differentiating depressive symptoms from HIV- and inflammatory-related somatic symptoms. When present, cognitive-affective and/or somatic symptoms cause significant impairment to patients’ lives and thus warrant further assessment and treatment. PMID:26883521

  12. Subtypes of depressive symptoms and inflammatory biomarkers: An exploratory study on a sample of HIV-positive patients.

    PubMed

    Norcini Pala, A; Steca, P; Bagrodia, R; Helpman, L; Colangeli, V; Viale, P; Wainberg, M L

    2016-08-01

    Depressive symptoms cause major impairment and may accelerate HIV progression despite the use of antiretroviral medication. The somatic symptoms criteria for HIV infection and depression partially overlap, which can make differential diagnosis challenging. Because of chronic inflammation caused by HIV infection, HIV-positive patients may develop somatic and affective-cognitive symptoms of depression. Inflammation-related depression is primarily characterized with severe somatic symptoms such as fatigue and sleep disturbance. This study sought to explore the patterns of somatic and cognitive-affective depressive symptoms that characterize HIV-positive patients. Our specific aims were (1) to identify subtypes of depressive symptoms in a sample of HIV-positive patients; and (2) to test the subtypes' difference on inflammatory and HIV disease progression biomarkers. HIV-positive men and women (N=102) with and without depressive symptoms were randomly selected from an Italian HIV clinic. Depressive symptoms (PHQ-9), viral load (VL), CD4+, Il-6, TNF-α, and monocytes were assessed. The three subtypes formed using Latent Class Analysis (LCA) identified patients with (1) severe cognitive-affective and somatic depressive symptoms; (2) severe/moderate somatic symptoms; and (3) absent or low depressive symptoms. The subtype with severe/moderate somatic symptoms was characterized with elevated levels of Il-6 and monocytes. No difference on HIV progression biomarkers was found. The subtypes of depressive symptoms might help differentiating depressive symptoms from HIV- and inflammatory-related somatic symptoms. When present, cognitive-affective and/or somatic symptoms cause significant impairment to patients' lives and thus warrant further assessment and treatment. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Newly developed liquid-based cytology. TACAS™: cytological appearance and HPV testing using liquid-based sample.

    PubMed

    Kubushiro, Kaneyuki; Taoka, Hideki; Sakurai, Nobuyuki; Yamamoto, Yasuhiro; Kurasaki, Akiko; Asakawa, Yasuyuki; Iwahara, Minoru; Takahashi, Kei

    2011-09-01

    Cell profiles determined by the thin-layer advanced cytology assay system (TACAS™), a liquid-based cytology technique newly developed in Japan, were analyzed in this study. Hybrid capture 2 (HC-2) was also performed using the liquid-based samples prepared by TACAS to ascertain its ability to detect human papillomavirus (HPV). Cell collection samples from uterine cervix were obtained from 359 patients and examined cytologically. A HC-2 assay for HPV was carried out in the cell specimens. All specimens were found to show background factors such as leukocytes. After excluding the 5 unsatisfactory cases from the total 354 cases, 82 cases (23.2%) were positive and 272 cases (76.8%) were negative for HPV. Cell specimens from 30 HPV-positive cases and 166 HPV-negative cases were subjected to 4 weeks of preservation at room temperature. Then, when subsequently re-assayed, 28 cases (93.3%) in the former group were found to be HPV positive and 164 cases (98.8%) in the latter group were found to be HPV negative. These results supported the excellent reproducibility of TACAS for HPV testing. A reasonable inference from the foregoing analysis is that TACAS may be distinguished from other liquid-based cytological approaches, such as ThinPrep and SurePath, in that it can retain the cell backgrounds. Furthermore, this study raises the possibility that cell specimens prepared using TACAS could be preserved for at least 4 weeks prior to carrying out a HC-2 assay for HPV.

  14. Stereo View of Phoenix Test Sample Site

    NASA Technical Reports Server (NTRS)

    2008-01-01

    This anaglyph image, acquired by NASA's Phoenix Lander's Surface Stereo Imager on Sol 7, the seventh day of the mission (June 1, 2008), shows a stereoscopic 3D view of the so-called 'Knave of Hearts' first-dig test area to the north of the lander. The Robotic Arm's scraping blade left a small horizontal depression above where the sample was taken.

    Scientists speculate that white material in the depression left by the dig could represent ice or salts that precipitated into the soil. This material is likely the same white material observed in the sample in the Robotic Arm's scoop.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  15. Associations between positive and negative affect and 12-month physical disorders in a national sample.

    PubMed

    Weiser, Eric B

    2012-06-01

    Associations between positive and negative affect and a range of 12-month physical disorders were investigated in the Midlife Development in the United States Survey, a nationally representative sample of 3,032 adults ages 25-74. These associations were examined, controlling for relevant sociodemographic and psychiatric covariates. High positive affect was associated with decreased risk of physical disorders, whereas high negative affect was associated with increased risk. However, associations between positive affect and physical disorders were partially attenuated following adjustment for concurrent negative affect. Additionally, high affect balance was associated with decreased risk of physical disorders before and after adjustments. These findings underscore the relevance of affective disposition in health status, suggesting that both positive and negative affect may serve as viable health risk parameters.

  16. The effects of sample size on population genomic analyses--implications for the tests of neutrality.

    PubMed

    Subramanian, Sankar

    2016-02-20

    One of the fundamental measures of molecular genetic variation is the Watterson's estimator (θ), which is based on the number of segregating sites. The estimation of θ is unbiased only under neutrality and constant population growth. It is well known that the estimation of θ is biased when these assumptions are violated. However, the effects of sample size in modulating the bias was not well appreciated. We examined this issue in detail based on large-scale exome data and robust simulations. Our investigation revealed that sample size appreciably influences θ estimation and this effect was much higher for constrained genomic regions than that of neutral regions. For instance, θ estimated for synonymous sites using 512 human exomes was 1.9 times higher than that obtained using 16 exomes. However, this difference was 2.5 times for the nonsynonymous sites of the same data. We observed a positive correlation between the rate of increase in θ estimates (with respect to the sample size) and the magnitude of selection pressure. For example, θ estimated for the nonsynonymous sites of highly constrained genes (dN/dS < 0.1) using 512 exomes was 3.6 times higher than that estimated using 16 exomes. In contrast this difference was only 2 times for the less constrained genes (dN/dS > 0.9). The results of this study reveal the extent of underestimation owing to small sample sizes and thus emphasize the importance of sample size in estimating a number of population genomic parameters. Our results have serious implications for neutrality tests such as Tajima D, Fu-Li D and those based on the McDonald and Kreitman test: Neutrality Index and the fraction of adaptive substitutions. For instance, use of 16 exomes produced 2.4 times higher proportion of adaptive substitutions compared to that obtained using 512 exomes (24% vs 10 %).

  17. Analytical liquid test sample filtration apparatus

    DOEpatents

    Lohnes, Brent C.; Turner, Terry D.; Klingler, Kerry M.; Clark, Michael L.

    1996-01-01

    A liquid sample filtration apparatus includes: a) a module retaining filter elements; b) a filter clamping and fluid injection apparatus positioned relative to the module to engage a filter element thereon, and includes a pair of first and second opposing engageable members to sealing engage a filter element therebetween; c) an inlet tube connected to an opposing engageable member; d) an outlet tube connected to an opposing engageable member; e) a motor to move the module relative to the filter clamping and injection apparatus to register filter elements on the module to the clamping and injection apparatus; and f) a motor associated with the filter clamping and injection apparatus to move the opposing engageable members into substantial sealing fluid communication relative to a filter element on the module. An apparatus for engaging opposing ends of a filter element includes: a) a member having a recess configured to engage one end of a filter element, including a first fluid passage communicating with the recess to pass fluid between the recess and externally of the member; and b) a second member positioned in opposing juxtaposition relative to the other member, and having a projection sized and shaped to matingly fit within the other member recess, the second member projection including a second recess configured to engage the other end of the filter element, the second member including a second fluid passage communicating with the second recess to pass fluid between the second recess and externally of the second member.

  18. Sample Dimensionality Effects on d' and Proportion of Correct Responses in Discrimination Testing.

    PubMed

    Bloom, David J; Lee, Soo-Yeun

    2016-09-01

    Products in the food and beverage industry have varying levels of dimensionality ranging from pure water to multicomponent food products, which can modify sensory perception and possibly influence discrimination testing results. The objectives of the study were to determine the impact of (1) sample dimensionality and (2) complex formulation changes on the d' and proportion of correct response of the 3-AFC and triangle methods. Two experiments were conducted using 47 prescreened subjects who performed either triangle or 3-AFC test procedures. In Experiment I, subjects performed 3-AFC and triangle tests using model solutions with different levels of dimensionality. Samples increased in dimensionality from 1-dimensional sucrose in water solution to 3-dimensional sucrose, citric acid, and flavor in water solution. In Experiment II, subjects performed 3-AFC and triangle tests using 3-dimensional solutions. Sample pairs differed in all 3 dimensions simultaneously to represent complex formulation changes. Two forms of complexity were compared: dilution, where all dimensions decreased in the same ratio, and compensation, where a dimension was increased to compensate for a reduction in another. The proportion of correct responses decreased for both methods when the dimensionality was increased from 1- to 2-dimensional samples. No reduction in correct responses was observed from 2- to 3-dimensional samples. No significant differences in d' were demonstrated between the 2 methods when samples with complex formulation changes were tested. Results reveal an impact on proportion of correct responses due to sample dimensionality and should be explored further using a wide range of sample formulations. © 2016 Institute of Food Technologists®

  19. Application and Comparative Evaluation of Fluorescent Antibody, Immunohistochemistry and Reverse Transcription Polymerase Chain Reaction Tests for the Detection of Rabies Virus Antigen or Nucleic Acid in Brain Samples of Animals Suspected of Rabies in India.

    PubMed

    Prabhu, K Nithin; Isloor, Shrikrishna; Veeresh, B Hanchinal; Rathnamma, Doddamane; Sharada, R; Das, Lekshmi J; Satyanarayana, M L; Hegde, Nagendra R; Rahman, Sira Abdul

    2018-02-28

    Accurate and early diagnosis of animal rabies is critical for undertaking public health measures. Whereas the direct fluorescent antibody (DFA) technique is the recommended test, the more convenient, direct rapid immunochemistry test (dRIT), as well as the more sensitive, reverse transcription polymerase chain reaction (RT-PCR), have recently been employed for the laboratory diagnosis of rabies. We compared the three methods on brain samples from domestic (dog, cat, cattle, buffalo, horse, pig and goat) and wild (leopard, wolf and jackal) animals from various parts of India. Of the 257 samples tested, 167 were positive by all the three tests; in addition, 35 of the 36 decomposed samples were positive by RT-PCR. This is the first study in which such large number of animal samples have been subjected to the three tests simultaneously. The results confirm 100% corroboration between DFA and dRIT, buttress the applicability of dRIT in the simple and rapid diagnosis of rabies in animals, and reaffirm the suitability of RT-PCR for samples unfit for testing either by DFA or dRIT.

  20. Comparison of the Abbott RealTime High Risk HPV test and the Roche cobas 4800 HPV test using urine samples.

    PubMed

    Lim, Myong Cheol; Lee, Do-Hoon; Hwang, Sang-Hyun; Hwang, Na Rae; Lee, Bomyee; Shin, Hye Young; Jun, Jae Kwan; Yoo, Chong Woo; Lee, Dong Ock; Seo, Sang-Soo; Park, Sang-Yoon; Joo, Jungnam

    2017-05-01

    Human papillomavirus (HPV) testing based on cervical samples is important for use in cervical cancer screening. However, cervical sampling is invasive. Therefore, non-invasive methods for detecting HPV, such as urine samples, are needed. For HPV detection in urine samples, two real-time PCR (RQ-PCR) tests, Roche cobas 4800 test (Roche_HPV; Roche Molecular Diagnostics) and Abbott RealTime High Risk HPV test (Abbott_HPV; Abbott Laboratories) were compared to standard cervical samples. The performance of Roche_HPV and Abbott_HPV for HPV detection was evaluated at the National Cancer Center using 100 paired cervical and urine samples. The tests were also compared using urine samples stored at various temperatures and for a range of durations. The overall agreement between the Roche_HPV and Abbott_HPV tests using urine samples for any hrHPV type was substantial (86.0% with a kappa value of 0.7173), and that for HPV 16/18 was nearly perfect (99.0% with a kappa value of 0.9668). The relative sensitivities (based on cervical samples) for HPV 16/18 detection using Roche_HPV and Abbott_HPV with urine samples were 79.2% (95% CI; 57.9-92.9%) and 81.8% (95% CI; 59.7-94.8%), respectively. When the cut-off C T value for Abbott_HPV was extended to 40 for urine samples, the relative sensitivity of Abbott_HPV increased to 91.7% from 81.8% for HPV16/18 detection and to 87.0% from 68.5% for other hrHPV detection. The specificity was not affected by the change in the C T threshold. Roche_HPV and Abbott_HPV showed high concordance. However, HPV DNA detection using urine samples was inferior to HPV DNA detection using cervical samples. Interestingly, when the cut-off C T value was set to 40, Abbott_HPV using urine samples showed high sensitivity and specificity, comparable to those obtained using cervical samples. Fully automated DNA extraction and detection systems, such as Roche_HPV and Abbott_HPV, could reduce the variability in HPV detection and accelerate the standardization of HPV

  1. Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    TEMPLETON, A.M.

    2000-03-06

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissionsmore » Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.« less

  2. Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    TEMPLETON, A.M.

    2000-01-31

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissionsmore » Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.« less

  3. Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    TEMPLETON, A.M.

    2000-04-10

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissionsmore » Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.« less

  4. Downregulation of external death receptor genes FAS and DR5 in colorectal cancer samples positive for human papillomavirus infection.

    PubMed

    Karbasi, Ashraf; Borhani, Nasim; Daliri, Karim; Kazemi, Bahram; Manoochehri, Mehdi

    2015-06-01

    Human papillomaviruses (HPV) have frequently been detected in colorectal cancer tumor samples, and may play a role in the pathogenesis of colorectal cancer. This study was designed to investigate the presence of DNA and RNA for the high-risk HPV genotypes 16 and 18 in samples of colorectal cancer tumors and adjacent normal tissues. We also investigated the expression of proapoptotic genes in HPV-positive colorectal tumors compared to normal tissue samples. Samples of tumoral and adjacent normal tissues were fresh-frozen, and HPV DNA was identified by nested and semiquantitative PCR. Real time PCR was used to quantitatively compare the expression of HPV-18 E6 and nine proapoptotic genes in HPV-positive tumors and samples of adjacent normal tissue. HPV-16 DNA was found in 10.5% of the tumor samples, and HPV-18 DNA was found in 23.6% of the samples. Real time PCR results showed lower expression of the E6 gene in HPV-positive tumors than in adjacent normal tissue. The expression of two proapoptotic genes, FAS and DR5, was significantly lower in tumor samples than in adjacent normal tissues. HPV infection, especially HPV-18, may play a role in colorectal cancer tumorigenesis by downregulating death receptor genes and interfering with the extrinsic pathway of apoptosis. Copyright © 2015 Elsevier GmbH. All rights reserved.

  5. Hydroxychloroquine-induced acute generalized exanthematous pustulosis with positive patch-testing.

    PubMed

    Charfi, Ons; Kastalli, Sarrah; Sahnoun, Rym; Lakhoua, Ghozlane

    2015-01-01

    Acute generalized exanthematous pustulosis (AGEP) is a severe cutaneous adverse reaction, mostly induced by drugs. Hydroxychloroquine have been rarely reported in literature as a causative drug of this reaction. We report a case of AGEP induced by hydroxychloroquine with systemic involvement and confirmed by positive patch testing.

  6. Difference of Diagnostic Rates and Analytical Methods in the Test Positions of Vestibular Evoked Myogenic Potentials

    PubMed Central

    Park, Jeong Mee; Yong, Sang Yeol; Kim, Jong Heon; Kim, Hee; Park, Sang-Yoo

    2014-01-01

    Objective To compare the differences of diagnostic rates, of the two widely used test positions, in measuring vestibular evoked myogenic potentials (VEMP) and selecting the most appropriate analytical method for diagnostic criteria for the patients with vertigo. Methods Thirty-two patients with vertigo were tested in two comparative testing positions: turning the head to the opposite side of the evaluating side and bowing while in seated position, and bowing while in supine positions. Abnormalities were determined by prolonged latency of p13 or n23, shortening of the interpeak latency, and absence of VEMP formation. Results Using the three criteria above for determining abnormalities, both the seated and supine positions showed no significant differences in diagnostic rates, however, the concordance correlation of the two positions was low. When using only the prolonged latency of p13 or n23 in the two positions, diagnostic rates were not significantly different and their concordance correlation was high. On the other hand, using only the shortened interpeak latency in both positions showed no significant difference of diagnostic rates, and the degree of agreement between two positions was low. Conclusion Bowing while in seated position with the head turned in the opposite direction to the area being evaluated is found to be the best VEMP test position due to the consistent level of sternocleidomastoid muscle tension and the high level of compliance. Also, among other diagnostic analysis methods, using prolonged latency of p13 or n23 as the criterion is found to be the most appropriate method of analysis for the VEMP test. PMID:24855617

  7. The effects of body position on distortion-product otoacoustic emission testing.

    PubMed

    Driscoll, Carlie; Kei, Joseph; Shyu, Jenny; Fukai, Natasha

    2004-09-01

    Otoacoustic emissions are frequently acquired from patients in a variety of body positions aside from the standard, seated orientation. Yet little knowledge is available regarding whether these deviations will produce nonpathological changes to the clinical results obtained. The present study aimed to describe the effects of body position on the distortion-product otoacoustic emissions of 60 normal-hearing adults. With particular attention given to common clinical practice, the Otodynamics ILO292, and the measurement parameters of amplitude, signal-to-noise ratio, and noise were utilized. Significant position-related effects and interactions were revealed for all parameters. Specifically, stronger emissions in the mid frequencies and higher noise levels at the extreme low and high frequencies were produced by testing subjects while lying on their side compared with the seated position. Further analysis of body position effects on emissions is warranted, in order to determine the need for clinical application of position-dependent normative data.

  8. Negativity bias and task motivation: testing the effectiveness of positively versus negatively framed incentives.

    PubMed

    Goldsmith, Kelly; Dhar, Ravi

    2013-12-01

    People are frequently challenged by goals that demand effort and persistence. As a consequence, philosophers, psychologists, economists, and others have studied the factors that enhance task motivation. Using a sample of undergraduate students and a sample of working adults, we demonstrate that the manner in which an incentive is framed has implications for individuals' task motivation. In both samples we find that individuals are less motivated when an incentive is framed as a means to accrue a gain (positive framing) as compared with when the same incentive is framed as a means to avoid a loss (negative framing). Further, we provide evidence for the role of the negativity bias in this effect, and highlight specific populations for whom positive framing may be least motivating. Interestingly, we find that people's intuitions about when they will be more motivated show the opposite pattern, with people predicting that positively framed incentives will be more motivating than negatively framed incentives. We identify a lay belief in the positive correlation between enjoyment and task motivation as one possible factor contributing to the disparity between predicted and actual motivation as a result of the framing of the incentive. We conclude with a discussion of the managerial implications for these findings. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  9. 23 CFR 637.209 - Laboratory and sampling and testing personnel qualifications.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... sampling and testing personnel. (c) Conflict of interest. In order to avoid an appearance of a conflict of interest, any qualified non-STD laboratory shall perform only one of the following types of testing on the...

  10. Detection of Cytomegalovirus (CMV) DNA in EDTA Whole-Blood Samples: Evaluation of the Quantitative artus CMV LightCycler PCR Kit in Conjunction with Automated Sample Preparation▿

    PubMed Central

    Michelin, Birgit D. A.; Hadžisejdić, Ita; Bozic, Michael; Grahovac, Maja; Hess, Markus; Grahovac, Blaženka; Marth, Egon; Kessler, Harald H.

    2008-01-01

    Whole blood has been found to be a reliable matrix for the detection and quantitation of cytomegalovirus (CMV) DNA. In this study, the performance of the artus CMV LightCycler (LC) PCR kit in conjunction with automated sample preparation on a BioRobot EZ1 workstation was evaluated. The accuracy, linearity, analytical sensitivity, and inter- and intra-assay variations were determined. A total of 102 clinical EDTA whole-blood samples were investigated, and results were compared with those obtained with the in vitro diagnostics (IVD)/Conformité Européene (CE)-labeled CMV HHV6,7,8 R-gene quantification kit. When the accuracy of the new kit was tested, seven of eight results were found to be within ±0.5 log10 unit of the expected panel results. Determination of linearity resulted in a quasilinear curve over more than 5 log units. The lower limit of detection of the assay was determined to be 139 copies/ml in EDTA whole blood. The interassay variation ranged from 15 to 58%, and the intra-assay variation ranged from 7 to 35%. When clinical samples were tested and the results were compared with those of the routinely used IVD/CE-labeled assay, 53 samples tested positive and 13 samples tested negative by both of the assays. One sample was found to be positive with the artus CMV LC PCR kit only, and 35 samples tested positive with the routinely used assay only. The majority of discrepant results were found with low-titer samples. In conclusion, use of the artus CMV LC PCR kit in conjunction with automated sample preparation on the BioRobot EZ1 workstation may be suitable for the detection and quantitation of CMV DNA in EDTA whole blood in the routine low-throughput laboratory; however, low-positive results may be missed by this assay. PMID:18272703

  11. Detection of cytomegalovirus (CMV) DNA in EDTA whole-blood samples: evaluation of the quantitative artus CMV LightCycler PCR kit in conjunction with automated sample preparation.

    PubMed

    Michelin, Birgit D A; Hadzisejdic, Ita; Bozic, Michael; Grahovac, Maja; Hess, Markus; Grahovac, Blazenka; Marth, Egon; Kessler, Harald H

    2008-04-01

    Whole blood has been found to be a reliable matrix for the detection and quantitation of cytomegalovirus (CMV) DNA. In this study, the performance of the artus CMV LightCycler (LC) PCR kit in conjunction with automated sample preparation on a BioRobot EZ1 workstation was evaluated. The accuracy, linearity, analytical sensitivity, and inter- and intra-assay variations were determined. A total of 102 clinical EDTA whole-blood samples were investigated, and results were compared with those obtained with the in vitro diagnostics (IVD)/Conformité Européene (CE)-labeled CMV HHV6,7,8 R-gene quantification kit. When the accuracy of the new kit was tested, seven of eight results were found to be within +/-0.5 log(10) unit of the expected panel results. Determination of linearity resulted in a quasilinear curve over more than 5 log units. The lower limit of detection of the assay was determined to be 139 copies/ml in EDTA whole blood. The interassay variation ranged from 15 to 58%, and the intra-assay variation ranged from 7 to 35%. When clinical samples were tested and the results were compared with those of the routinely used IVD/CE-labeled assay, 53 samples tested positive and 13 samples tested negative by both of the assays. One sample was found to be positive with the artus CMV LC PCR kit only, and 35 samples tested positive with the routinely used assay only. The majority of discrepant results were found with low-titer samples. In conclusion, use of the artus CMV LC PCR kit in conjunction with automated sample preparation on the BioRobot EZ1 workstation may be suitable for the detection and quantitation of CMV DNA in EDTA whole blood in the routine low-throughput laboratory; however, low-positive results may be missed by this assay.

  12. 40 CFR 1065.1109 - Post-test sampler disassembly and sample extraction.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Post-test sampler disassembly and... Semi-Volatile Organic Compounds § 1065.1109 Post-test sampler disassembly and sample extraction. This... environment as follows after the test: (1) Remove the PM filter, PUF plugs, and all the XAD-2 from the...

  13. Harmonisation of microbial sampling and testing methods for distillate fuels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hill, G.C.; Hill, E.C.

    1995-05-01

    Increased incidence of microbial infection in distillate fuels has led to a demand for organisations such as the Institute of Petroleum to propose standards for microbiological quality, based on numbers of viable microbial colony forming units. Variations in quality requirements, and in the spoilage significance of contaminating microbes plus a tendency for temporal and spatial changes in the distribution of microbes, makes such standards difficult to implement. The problem is compounded by a diversity in the procedures employed for sampling and testing for microbial contamination and in the interpretation of the data obtained. The following paper reviews these problems andmore » describes the efforts of The Institute of Petroleum Microbiology Fuels Group to address these issues and in particular to bring about harmonisation of sampling and testing methods. The benefits and drawbacks of available test methods, both laboratory based and on-site, are discussed.« less

  14. Evaluation of Verigene Blood Culture Test Systems for Rapid Identification of Positive Blood Cultures.

    PubMed

    Kim, Jae-Seok; Kang, Go-Eun; Kim, Han-Sung; Kim, Hyun Soo; Song, Wonkeun; Lee, Kyu Man

    2016-01-01

    The performance of molecular tests using the Verigene Gram-Positive and Gram-Negative Blood Culture nucleic acid tests (BC-GP and BC-GN, resp.; Naosphere, Northbrook, IL, USA) was evaluated for the identification of microorganisms detected from blood cultures. Ninety-nine blood cultures containing Gram-positive bacteria and 150 containing Gram-negative bacteria were analyzed using the BC-GP and BC-GN assays, respectively. Blood cultures were performed using the Bactec blood culture system (BD Diagnostic Systems, Franklin Lakes, NJ, USA) and conventional identification and antibiotic-susceptibility tests were performed using a MicroScan system (Siemens, West Sacramento, CA, USA). When a single strain of bacteria was isolated from the blood culture, Verigene assays correctly identified 97.9% (94/96) of Gram-positive bacteria and 93.8% (137/146) of Gram-negative bacteria. Resistance genes mecA and vanA were correctly detected by the BC-GP assay, while the extended-spectrum β-lactamase CTX-M and the carbapenemase OXA resistance gene were detected from 30 cases cultures by the BC-GN assay. The BC-GP and BC-GN assays showed high agreement with conventional identification and susceptibility tests. These tests are useful for rapid identification of microorganisms and the detection of clinically important resistance genes from positive Bactec blood cultures.

  15. Poor Positive Predictive Value of Lyme Disease Serologic Testing in an Area of Low Disease Incidence

    PubMed Central

    Lantos, Paul M.; Branda, John A.; Boggan, Joel C.; Chudgar, Saumil M.; Wilson, Elizabeth A.; Ruffin, Felicia; Fowler, Vance; Auwaerter, Paul G.; Nigrovic, Lise E.

    2015-01-01

    Background. Lyme disease is diagnosed by 2-tiered serologic testing in patients with a compatible clinical illness, but the significance of positive test results in low-prevalence regions has not been investigated. Methods. We reviewed the medical records of patients who tested positive for Lyme disease with standardized 2-tiered serologic testing between 2005 and 2010 at a single hospital system in a region with little endemic Lyme disease. Based on clinical findings, we calculated the positive predictive value of Lyme disease serology. Next, we reviewed the outcome of serologic testing in patients with select clinical syndromes compatible with disseminated Lyme disease (arthritis, cranial neuropathy, or meningitis). Results. During the 6-year study period 4723 patients were tested for Lyme disease, but only 76 (1.6%) had positive results by established laboratory criteria. Among 70 seropositive patients whose medical records were available for review, 12 (17%; 95% confidence interval, 9%–28%) were found to have Lyme disease (6 with documented travel to endemic regions). During the same time period, 297 patients with a clinical illness compatible with disseminated Lyme disease underwent 2-tiered serologic testing. Six of them (2%; 95% confidence interval, 0.7%–4.3%) were seropositive, 3 with documented travel and 1 who had an alternative diagnosis that explained the clinical findings. Conclusions. In this low-prevalence cohort, fewer than 20% of positive Lyme disease tests are obtained from patients with clinically likely Lyme disease. Positive Lyme disease test results may have little diagnostic value in this setting. PMID:26195017

  16. tscvh R Package: Computational of the two samples test on microarray-sequencing data

    NASA Astrophysics Data System (ADS)

    Fajriyah, Rohmatul; Rosadi, Dedi

    2017-12-01

    We present a new R package, a tscvh (two samples cross-variance homogeneity), as we called it. This package is a software of the cross-variance statistical test which has been proposed and introduced by Fajriyah ([3] and [4]), based on the cross-variance concept. The test can be used as an alternative test for the significance difference between two means when sample size is small, the situation which is usually appeared in the bioinformatics research. Based on its statistical distribution, the p-value can be also provided. The package is built under a homogeneity of variance between samples.

  17. Antibiotic-induced immediate type hypersensitivity is a risk factor for positive allergy skin tests for neuromuscular blocking agents.

    PubMed

    Hagau, Natalia; Gherman, Nadia; Cocis, Mihaela; Petrisor, Cristina

    2016-01-01

    Skin tests for neuromuscular blocking agents (NMBAs) are not currently recommended for the general population undergoing general anaesthesia. In a previous study we have reported a high incidence of positive allergy tests for NMBAs in patients with a positive history of non-anaesthetic drug allergy, a larger prospective study being needed to confirm those preliminary results. The objective of this study was to compare the skin tests results for patients with a positive history of antibiotic-induced immediate type hypersensitivity reactions to those of controls without drug allergies. Ninety eight patients with previous antibiotic hypersensitivity and 72 controls were prospectively included. Skin tests were performed for atracurium, pancuronium, rocuronium, and suxamethonium. We found 65 positive skin tests from the 392 tests performed in patients with a positive history of antibiotic hypersensitivity (1 6.58%) and 23 positive skin tests from the 288 performed in controls (7.98%), the two incidences showing significant statistical difference (p = 0.0011). The relative risk for having a positive skin test for NMBAs for patients versus controls was 1.77 (1.15-2.76). For atracurium, skin tests were more often positive in patients with a positive history of antibiotic hypersensitivity versus controls (p = 0.02). For pancuronium, rocuronium and suxamethonium the statistical difference was not attained (p-values 0.08 for pancuronium, 0.23 for rocuronium, and 0.26 for suxamethonium). Patients with a positive history of antibiotic hypersensitivity seem to have a higher incidence of positive skin tests for NMBAs. They might represent a group at higher risk for developing intraoperative anaphylaxis compared to the general population. Copyright © 2015 The Authors. Production and hosting by Elsevier B.V. All rights reserved.

  18. [Tropheryma whipplei and Whipple disease: false positive PCR detections of Tropheryma whipplei in diagnostic samples are rare].

    PubMed

    Le Scanff, J; Gaultier, J B; Durand, D Vital; Durieu, I; Celard, M; Benito, Y; Vandenesch, F; Rousset, H

    2008-11-01

    PCR can be used to detect T. whipplei (Tw) in samples from variable tissue types and body fluids. We report clinical, evolutive characteristics and final diagnosis in patients with positive Tw PCR assay. Retrospective study of Tw PCR realized since 10years in a microbiology laboratory. Twenty-five Tw PCR assays were positive among 200 realized. Diagnosis was not confirmed in six cases. One patient was missing for follow up. Eighteen patients presented with Whipple's disease. Among these 18 patients, 14 had a classic Whipple's disease, three patients presented an endocarditis and one patient isolated neurological manifestations. Ten patients presented fever, seven a weight loss and 12 joint involvement. Four patients presented cutaneous manifestations, only six had gastrointestinal symptoms. Neurological involvement was reported in five cases, pulmonary symptoms in four cases, cardiac involvement in six cases and ocular signs in two cases. Anemia was reported in four patients and elevated levels of acute-phase reactants in 14 cases. Positive predictive value of Tw PCR for Whipple's disease diagnosis was 75%. Thirteen patients had a good evolution with antibiotics. Three patients presented recurrence and two cases with cardiovascular involvement died. Whipple's disease is rare but often mentioned in internist experience. The diagnosis should be every time confirmed. Tw PCR assay is an important diagnostic tool but is not sufficient to establish the diagnosis and must be interpreted with histopathology and immunohistochemical testing results.

  19. Analytical liquid test sample filtration apparatus

    DOEpatents

    Lohnes, B.C.; Turner, T.D.; Klingler, K.M.; Clark, M.L.

    1996-01-09

    A liquid sample filtration apparatus includes: (a) a module retaining filter elements; (b) a filter clamping and fluid injection apparatus positioned relative to the module to engage a filter element thereon, and includes a pair of first and second opposing engageable members to engage a filter element there between; (c) an inlet tube connected to an opposing engageable member; (d) an outlet tube connected to an opposing engageable member; (e) a motor to move the module relative to the filter clamping and injection apparatus to register filter elements on the module to the clamping and injection apparatus; and (f) a motor associated with the filter clamping and injection apparatus to move the opposing engageable members into substantial sealing fluid communication relative to a filter element on the module. An apparatus for engaging opposing ends of a filter element includes: (a) a member having a recess configured to engage one end of a filter element, including a first fluid passage communicating with the recess to pass fluid between the recess and externally of the member; and (b) a second member positioned in opposing juxtaposition relative to the other member, and having a projection sized and shaped to matingly fit within the other member recess, the second member projection including a second recess configured to engage the other end of the filter element, the second member including a second fluid passage communicating with the second recess to pass fluid between the second recess and externally of the second member. 8 figs.

  20. Estimation of AUC or Partial AUC under Test-Result-Dependent Sampling.

    PubMed

    Wang, Xiaofei; Ma, Junling; George, Stephen; Zhou, Haibo

    2012-01-01

    The area under the ROC curve (AUC) and partial area under the ROC curve (pAUC) are summary measures used to assess the accuracy of a biomarker in discriminating true disease status. The standard sampling approach used in biomarker validation studies is often inefficient and costly, especially when ascertaining the true disease status is costly and invasive. To improve efficiency and reduce the cost of biomarker validation studies, we consider a test-result-dependent sampling (TDS) scheme, in which subject selection for determining the disease state is dependent on the result of a biomarker assay. We first estimate the test-result distribution using data arising from the TDS design. With the estimated empirical test-result distribution, we propose consistent nonparametric estimators for AUC and pAUC and establish the asymptotic properties of the proposed estimators. Simulation studies show that the proposed estimators have good finite sample properties and that the TDS design yields more efficient AUC and pAUC estimates than a simple random sampling (SRS) design. A data example based on an ongoing cancer clinical trial is provided to illustrate the TDS design and the proposed estimators. This work can find broad applications in design and analysis of biomarker validation studies.

  1. Buprenorphine detection in hair samples by immunometric screening test: preliminary experience.

    PubMed

    Svaizer, Fiorenza; Lotti, Andrea; Gottardi, Massimo; Miozzo, Maria Pia

    2010-03-20

    The recent introduction of buprenorphine use by the Drug Addiction Services has induced toxicology laboratories to develop new qualitative or semiquantitative screening assay for its determination in hair samples. The aim of this preliminary study was to verify the correlation between the buprenorphine intake and the immunometric screening test results (VMA-T Comedical and buprenorphine CEDIA/Thermo-Fisher/Microgenics reagents) and therefore their comparison with the liquid chromatography coupled with mass spectrometry (LC/MS) results. Hair samples were obtained from 32 subjects without buprenorphine-therapy reported and 17 in treatment. In glass test tube with hermetic cap were weighed 33 mg of 49 finely cut hair samples, washed with 1 mL of SLV-VMA-T washing solution, which is then completely sucked and eliminated. The samples were extracted with 400 microL of VMA-T reagent for an hour at 100 degrees C. The extracts were analysed by immunometric screening test on ILab 650 chemistry analyser, using buprenorphine CEDIA reagent assay. From the 32 non-takers of drug, 30 semiquantitative results were less than 10 pg/mg and 2 were over 10 pg/mg; from the 17 subjects with therapy, all were over 10 pg/mg (range 13-50 pg/mg); no samples were false-negative. Results suggest that exist a good relationship between the administration of buprenorphine and its concentration in hair, detectable through this method and reagents line. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  2. Recent testing of a micro autonomous positioning system for multi-object instrumentation

    NASA Astrophysics Data System (ADS)

    Cochrane, W. A.; Atkinson, D. C.; Bailie, T. E. C.; Dickson, C.; Lim, T.; Luo, X.; Montgomery, D. M.; Schnetler, H.; Taylor, W. D.; Wilson, B.

    2012-09-01

    A multiple pick off mirror positioning sub-system has been developed as a solution for the deployment of mirrors within multi-object instrumentation such as the EAGLE instrument in the European Extremely Large Telescope (E-ELT). The positioning sub-system is a two wheeled differential steered friction drive robot with a footprint of approximately 20 x 20 mm. Controlled by RF communications there are two versions of the robot that exist. One is powered by a single cell lithium ion battery and the other utilises a power floor system. The robots use two brushless DC motors with 125:1 planetary gear heads for positioning in the coarse drive stages. A unique power floor allows the robots to be positioned at any location in any orientation on the focal plane. The design, linear repeatability tests, metrology and power continuity of the robot will be evaluated and presented in this paper. To gather photons from the objects of interest it is important to position POMs within a sphere of confusion of less than 10 μm, with an angular alignment better than 1 mrad. The robots potential of meeting these requirements will be described through the open-loop repeatability tests conducted with a Faro laser beam tracker. Tests have involved sending the robot step commands and automatically taking continuous measurements every three seconds. Currently the robot is capable of repeatedly travelling 233 mm within 0.307 mm at 5 mm/s. An analysis of the power floors reliability through the continuous monitoring of the voltage across the tracks with a Pico logger will also be presented.

  3. Genotyping for Human Papillomavirus (HPV) 16/18/52/58 Has a Higher Performance than HPV16/18 Genotyping in Triaging Women with Positive High-risk HPV Test in Northern Thailand

    PubMed Central

    Khunamornpong, Surapan; Settakorn, Jongkolnee; Sukpan, Kornkanok; Suprasert, Prapaporn; Srisomboon, Jatupol; Intaraphet, Suthida; Siriaunkgul, Sumalee

    2016-01-01

    Background Testing for high-risk human papillomavirus DNA (HPV test) has gained increasing acceptance as an alternative method to cytology in cervical cancer screening. Compared to cytology, HPV test has a higher sensitivity for the detection of histologic high-grade squamous intraepithelial lesion or worse (HSIL+), but this could lead to a large colposcopy burden. Genotyping for HPV16/18 has been recommended in triaging HPV-positive women. This study was aimed to evaluate the screening performance of HPV testing and the role of genotyping triage in Northern Thailand. Methods A population-based cervical screening program was performed in Chiang Mai (Northern Thailand) using cytology (conventional Pap test) and HPV test (Hybrid Capture 2). Women who had abnormal cytology or were HPV-positive were referred for colposcopy. Cervical samples from these women were genotyped using the Linear Array assay. Results Of 5,456 women, 2.0% had abnormal Pap test results and 6.5% tested positive with Hybrid Capture 2. Of 5,433 women eligible for analysis, 355 with any positive test had histologic confirmation and 57 of these had histologic HSIL+. The sensitivity for histologic HSIL+ detection was 64.9% for Pap test and 100% for Hybrid Capture 2, but the ratio of colposcopy per detection of each HSIL+ was more than two-fold higher with Hybrid Capture 2 than Pap test (5.9 versus 2.8). Genotyping results were available in 316 samples. HPV52, HPV16, and HPV58 were the three most common genotypes among women with histologic HSIL+. Performance of genotyping triage using HPV16/18/52/58 was superior to that of HPV16/18, with a higher sensitivity (85.7% versus 28.6%) and negative predictive value (94.2% versus 83.9%). Conclusions In Northern Thailand, HPV testing with genotyping triage shows better screening performance than cervical cytology alone. In this region, the addition of genotyping for HPV52/58 to HPV16/18 is deemed necessary in triaging women with positive HPV test. PMID

  4. Mold Testing or Sampling

    EPA Pesticide Factsheets

    In most cases, if visible mold growth is present, sampling is unnecessary. Since no EPA or other federal limits have been set for mold or mold spores, sampling cannot be used to check a building's compliance with federal mold standards.

  5. Poor Positive Predictive Value of Lyme Disease Serologic Testing in an Area of Low Disease Incidence.

    PubMed

    Lantos, Paul M; Branda, John A; Boggan, Joel C; Chudgar, Saumil M; Wilson, Elizabeth A; Ruffin, Felicia; Fowler, Vance; Auwaerter, Paul G; Nigrovic, Lise E

    2015-11-01

    Lyme disease is diagnosed by 2-tiered serologic testing in patients with a compatible clinical illness, but the significance of positive test results in low-prevalence regions has not been investigated. We reviewed the medical records of patients who tested positive for Lyme disease with standardized 2-tiered serologic testing between 2005 and 2010 at a single hospital system in a region with little endemic Lyme disease. Based on clinical findings, we calculated the positive predictive value of Lyme disease serology. Next, we reviewed the outcome of serologic testing in patients with select clinical syndromes compatible with disseminated Lyme disease (arthritis, cranial neuropathy, or meningitis). During the 6-year study period 4723 patients were tested for Lyme disease, but only 76 (1.6%) had positive results by established laboratory criteria. Among 70 seropositive patients whose medical records were available for review, 12 (17%; 95% confidence interval, 9%-28%) were found to have Lyme disease (6 with documented travel to endemic regions). During the same time period, 297 patients with a clinical illness compatible with disseminated Lyme disease underwent 2-tiered serologic testing. Six of them (2%; 95% confidence interval, 0.7%-4.3%) were seropositive, 3 with documented travel and 1 who had an alternative diagnosis that explained the clinical findings. In this low-prevalence cohort, fewer than 20% of positive Lyme disease tests are obtained from patients with clinically likely Lyme disease. Positive Lyme disease test results may have little diagnostic value in this setting. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  6. 47 CFR 2.945 - Sampling tests of equipment compliance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Sampling tests of equipment compliance. 2.945 Section 2.945 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL FREQUENCY ALLOCATIONS AND RADIO TREATY MATTERS; GENERAL RULES AND REGULATIONS Equipment Authorization Procedures Conditions Attendant to An Equipment Authorization § 2.945...

  7. Solubility testing of actinides on breathing-zone and area air samples

    NASA Astrophysics Data System (ADS)

    Metzger, Robert Lawrence

    The solubility of inhaled radionuclides in the human lung is an important characteristic of the compounds needed to perform internal dosimetry assessments for exposed workers. A solubility testing method for uranium and several common actinides has been developed with sufficient sensitivity to allow profiles to be determined from routine breathing zone and area air samples in the workplace. Air samples are covered with a clean filter to form a filter-sample-filter sandwich which is immersed in an extracellular lung serum simulant solution. The sample is moved to a fresh beaker of the lung fluid simulant each day for one week, and then weekly until the end of the 28 day test period. The soak solutions are wet ashed with nitric acid and hydrogen peroxide to destroy the organic components of the lung simulant solution prior to extraction of the nuclides of interest directly into an extractive scintillator for subsequent counting on a Photon-Electron Rejecting Alpha Liquid Scintillation (PERALSsp°ler ) spectrometer. Solvent extraction methods utilizing the extractive scintillators have been developed for the isotopes of uranium, plutonium, and curium. The procedures normally produce an isotopic recovery greater than 95% and have been used to develop solubility profiles from air samples with 40 pCi or less of Usb3Osb8. This makes it possible to characterize solubility profiles in every section of operating facilities where airborne nuclides are found using common breathing zone air samples. The new method was evaluated by analyzing uranium compounds from two uranium mills whose product had been previously analyzed by in vitro solubility testing in the laboratory and in vivo solubility testing in rodents. The new technique compared well with the in vivo rodent solubility profiles. The method was then used to evaluate the solubility profiles in all process sections of an operating in situ uranium plant using breathing zone and area air samples collected during routine

  8. 21 CFR 211.110 - Sampling and testing of in-process materials and drug products.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 4 2012-04-01 2012-04-01 false Sampling and testing of in-process materials and... PHARMACEUTICALS Production and Process Controls § 211.110 Sampling and testing of in-process materials and drug... testing. (b) Valid in-process specifications for such characteristics shall be consistent with drug...

  9. 21 CFR 211.110 - Sampling and testing of in-process materials and drug products.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Sampling and testing of in-process materials and... PHARMACEUTICALS Production and Process Controls § 211.110 Sampling and testing of in-process materials and drug... testing. (b) Valid in-process specifications for such characteristics shall be consistent with drug...

  10. 21 CFR 211.110 - Sampling and testing of in-process materials and drug products.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 4 2013-04-01 2013-04-01 false Sampling and testing of in-process materials and... PHARMACEUTICALS Production and Process Controls § 211.110 Sampling and testing of in-process materials and drug... testing. (b) Valid in-process specifications for such characteristics shall be consistent with drug...

  11. 21 CFR 211.110 - Sampling and testing of in-process materials and drug products.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Sampling and testing of in-process materials and... PHARMACEUTICALS Production and Process Controls § 211.110 Sampling and testing of in-process materials and drug... testing. (b) Valid in-process specifications for such characteristics shall be consistent with drug...

  12. 21 CFR 211.110 - Sampling and testing of in-process materials and drug products.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 4 2014-04-01 2014-04-01 false Sampling and testing of in-process materials and... PHARMACEUTICALS Production and Process Controls § 211.110 Sampling and testing of in-process materials and drug... testing. (b) Valid in-process specifications for such characteristics shall be consistent with drug...

  13. Helminths and skewed cytokine profiles increase tuberculin skin test positivity in Warao Amerindians.

    PubMed

    Verhagen, L M; Hermans, P W M; Warris, A; de Groot, R; Maes, M; Villalba, J A; del Nogal, B; van den Hof, S; Mughini Gras, L; van Soolingen, D; Pinelli, E; de Waard, J H

    2012-11-01

    The immune regulatory mechanisms involved in the acquisition of Mycobacterium tuberculosis infection in children are largely unknown. We investigated the influence of parasitic infections, malnutrition and plasma cytokine profiles on tuberculin skin test (TST) positivity in Warao Amerindians in Venezuela. Pediatric household contacts of sputum smear-positive tuberculosis (TB) cases were enrolled for TST, chest radiograph, plasma cytokine analyses, QuantiFERON-TB Gold In-Tube (QFT-GIT) testing and stool examinations. Factors associated with TST positivity were studied using generalized estimation equations logistic regression models. Of the 141 asymptomatic contacts, 39% was TST-positive. After adjusting for age, gender and nutritional status, TST positivity was associated with Trichuris trichiura infections (OR 3.5, 95% CI 1.1-11.6) and low circulating levels of T helper 1 (Th1) cytokines (OR 0.51, 95% CI 0.33-0.79). Ascaris lumbricoides infections in interaction with Th2- and interleukin (IL)-10-dominated cytokine profiles were positively associated with TST positivity (OR 3.1, 95% CI 1.1-8.9 and OR 2.4, 95% CI 1.04-5.7, respectively). A negative correlation of QFT-GIT mitogen responses with Th1 and Th2 levels and a positive correlation with age were observed (all p < 0.01). We conclude that helminth infections and low Th1 cytokine plasma levels are significantly associated with TST positivity in indigenous Venezuelan pediatric TB contacts. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic...

  15. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic...

  16. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic...

  17. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic...

  18. Development of NASA's Sample Cartridge Assembly: Summary of GEDS Design, Development Testing, and Thermal Analyses

    NASA Technical Reports Server (NTRS)

    O'Connor, Brian; Hernandez, Deborah; Hornsby, Linda; Brown, Maria; Horton-Mullins, Kathryn

    2017-01-01

    Outline: Background of ISS (International Space Station) Material Science Research Rack; NASA SCA (Sample Cartridge Assembly) Design; GEDS (Gravitational Effects in Distortion in Sintering) Experiment Ampoule Design; Development Testing Summary; Thermal Modeling and Analysis. Summary: GEDS design development challenging (GEDS Ampoule design developed through MUGS (Microgravity) testing; Short duration transient sample processing; Unable to measure sample temperatures); MUGS Development testing used to gather data (Actual LGF (Low Gradient Furnace)-like furnace response; Provided sample for sintering evaluation); Transient thermal model integral to successful GEDS experiment (Development testing provided furnace response; PI (Performance Indicator) evaluation of sintering anchored model evaluation of processing durations; Thermal transient model used to determine flight SCA sample processing profiles).

  19. Testing of a Microfluidic Sampling System for High Temperature Electrochemical MC&A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pereira, Candido; Nichols, Kevin

    2013-11-27

    This report describes the preliminary validation of a high-temperature microfluidic chip system for sampling of electrochemical process salt. Electroanalytical and spectroscopic techniques are attractive candidates for improvement through high-throughput sample analysis via miniaturization. Further, microfluidic chip systems are amenable to micro-scale chemical processing such as rapid, automated sample purification to improve sensor performance. The microfluidic chip was tested to determine the feasibility of the system for high temperature applications and conditions under which microfluidic systems can be used to generate salt droplets at process temperature to support development of material balance and control systems in a used fuel treatment facility.more » In FY13, the project focused on testing a quartz microchip device with molten salts at near process temperatures. The equipment was installed in glove box and tested up to 400°C using commercial thermal transfer fluids as the carrier phase. Preliminary tests were carried out with a low-melting halide salt to initially characterize the properties of this novel liquid-liquid system and to investigate the operating regimes for inducing droplet flow within candidate carrier fluids. Initial results show that the concept is viable for high temperature sampling but further development is required to optimize the system to operate with process relevant molten salts.« less

  20. ALK rearrangement testing and treatment patterns for patients with ALK-positive non-small cell lung cancer.

    PubMed

    Guérin, Annie; Sasane, Medha; Zhang, Jie; Macalalad, Alexander R; Galebach, Philip; Jarvis, John; Kageleiry, Andrew; Culver, Kenneth; Wu, Eric Q; Wakelee, Heather

    2015-06-01

    Approximately 2-8% of non-small cell lung cancer (NSCLC) patients have rearrangements in the anaplastic lymphoma kinase gene (ALK). ALK-targeted therapy is available to patients with tumors known to be ALK+. This chart review study described characteristics of patients with ALK+ NSCLC, patterns of ALK testing and subsequent treatments, and oncologists' experience with ALK testing in the US. US oncologists provided information in September and October of 2013 on patients from their practice diagnosed with ALK+ locally advanced or metastatic NSCLC, including the timing of ALK testing and treatment received after testing. Participating oncologists were also surveyed about their experience with ALK testing. 27 oncologists provided data on 273 ALK+ NSCLC patients. Patients' median age was 67 years upon NSCLC diagnosis. Smoking history varied, with 33% nonsmokers, 33% light smokers, and 33% heavy smokers. Patients were racially diverse: 59% White, 18% Black, 13% Asian, and 10% other. Upon diagnosis of advanced/metastatic NSCLC, patients who were either not tested (19%) or initially tested negative/inconclusive (1%) all received first-line chemotherapy; the other 219 patients (80%) tested positive, with 133 (61%) receiving an ALK inhibitor and 78 (29%) receiving chemotherapy as first-line treatment. Many oncologists stated being more likely to test for ALK rearrangements among Asians, nonsmokers, and light smokers. In this sample, ALK+ NSCLC patients were racially diverse with mixed smoking history. One in five patients were not tested before first-line therapy. Oncologists reported being more likely to consider ALK testing for patients with particular smoking and race characteristics. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Analysis of small sample size studies using nonparametric bootstrap test with pooled resampling method.

    PubMed

    Dwivedi, Alok Kumar; Mallawaarachchi, Indika; Alvarado, Luis A

    2017-06-30

    Experimental studies in biomedical research frequently pose analytical problems related to small sample size. In such studies, there are conflicting findings regarding the choice of parametric and nonparametric analysis, especially with non-normal data. In such instances, some methodologists questioned the validity of parametric tests and suggested nonparametric tests. In contrast, other methodologists found nonparametric tests to be too conservative and less powerful and thus preferred using parametric tests. Some researchers have recommended using a bootstrap test; however, this method also has small sample size limitation. We used a pooled method in nonparametric bootstrap test that may overcome the problem related with small samples in hypothesis testing. The present study compared nonparametric bootstrap test with pooled resampling method corresponding to parametric, nonparametric, and permutation tests through extensive simulations under various conditions and using real data examples. The nonparametric pooled bootstrap t-test provided equal or greater power for comparing two means as compared with unpaired t-test, Welch t-test, Wilcoxon rank sum test, and permutation test while maintaining type I error probability for any conditions except for Cauchy and extreme variable lognormal distributions. In such cases, we suggest using an exact Wilcoxon rank sum test. Nonparametric bootstrap paired t-test also provided better performance than other alternatives. Nonparametric bootstrap test provided benefit over exact Kruskal-Wallis test. We suggest using nonparametric bootstrap test with pooled resampling method for comparing paired or unpaired means and for validating the one way analysis of variance test results for non-normal data in small sample size studies. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  2. [The Amsterdam Dementia Screening Test in cognitively healthy and clinical samples. An update of normative data].

    PubMed

    van Toutert, Meta; Diesfeldt, Han; Hoek, Dirk

    2016-10-01

    The six tests in the Amsterdam Dementia Screening Test (ADST) examine the cognitive domains of episodic memory (delayed picture recognition, word learning), orientation, category fluency (animals and occupations), constructional ability (figure copying) and executive function (alternating sequences). New normative data were collected in a sample of 102 elderly volunteers (aged 65-94), including subjects with medical or other health conditions, except dementia or frank cognitive impairment (MMSE > 24). Included subjects were independent in complex instrumental activities of daily living.Fluency, not the other tests, needed adjustment for age and education. A deficit score (0-1) was computed for each test. Summation (range 0-6) proved useful in differentiating patients with dementia (N = 741) from normal elderly (N = 102).Positive and negative predictive power across a range of summed deficit scores and base rates are displayed in Bayesian probability tables.In the normal elderly, delayed recall for eight words was tested and adjusted for initial recall. A recognition test mixed the target words with eight distractors. Delayed recognition was adjusted for immediate and delayed recall.The ADST and the normative data in this paper help the clinical neuropsychologist to make decisions concerning the presence or absence of neurocognitive disorder in individual elderly examinees.

  3. Sample introduction apparatus for a flow cytometer

    DOEpatents

    Van den Engh, Ger

    1998-01-01

    A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning HPLC tubing and fittings may be used in a manner which facilitates removable of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it.

  4. Sample introduction system for a flow cytometer

    DOEpatents

    Van den Engh, Ger

    1997-01-01

    A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning, HPLC tubing and fittings may be used in a manner which facilitates removing of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it.

  5. Sample introduction apparatus for a flow cytometer

    DOEpatents

    Van den Engh, G.

    1998-03-10

    A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning HPLC tubing and fittings may be used in a manner which facilitates removable of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it. 3 figs.

  6. Sample introduction system for a flow cytometer

    DOEpatents

    Engh, G. van den

    1997-02-11

    A sample introduction system for a flow cytometer allows easy change of sample containers such as test tubes and facilitates use in high pressure environments. The sample container includes a cap having a pressure supply chamber and a sample container attachment cavity. A sample container may be automatically positioned into the attachment cavity so as to sealably engage the end of the sample container as its outer surface. This positioning may be accomplished through some sample introduction mechanism. To facilitate cleaning, HPLC tubing and fittings may be used in a manner which facilitates removing of the entire tubing from both the nozzle container and other sample container cap to permit its replacement to avoid contamination. The sample container support may include horizontal stops which loosely limit the movement of the sample container and thus avoid further stresses upon it. 3 figs.

  7. Evaluation of sampling methods for toxicological testing of indoor air particulate matter.

    PubMed

    Tirkkonen, Jenni; Täubel, Martin; Hirvonen, Maija-Riitta; Leppänen, Hanna; Lindsley, William G; Chen, Bean T; Hyvärinen, Anne; Huttunen, Kati

    2016-09-01

    There is a need for toxicity tests capable of recognizing indoor environments with compromised air quality, especially in the context of moisture damage. One of the key issues is sampling, which should both provide meaningful material for analyses and fulfill requirements imposed by practitioners using toxicity tests for health risk assessment. We aimed to evaluate different existing methods of sampling indoor particulate matter (PM) to develop a suitable sampling strategy for a toxicological assay. During three sampling campaigns in moisture-damaged and non-damaged school buildings, we evaluated one passive and three active sampling methods: the Settled Dust Box (SDB), the Button Aerosol Sampler, the Harvard Impactor and the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Cyclone Sampler. Mouse RAW264.7 macrophages were exposed to particle suspensions and cell metabolic activity (CMA), production of nitric oxide (NO) and tumor necrosis factor (TNFα) were determined after 24 h of exposure. The repeatability of the toxicological analyses was very good for all tested sampler types. Variability within the schools was found to be high especially between different classrooms in the moisture-damaged school. Passively collected settled dust and PM collected actively with the NIOSH Sampler (Stage 1) caused a clear response in exposed cells. The results suggested the higher relative immunotoxicological activity of dust from the moisture-damaged school. The NIOSH Sampler is a promising candidate for the collection of size-fractionated PM to be used in toxicity testing. The applicability of such sampling strategy in grading moisture damage severity in buildings needs to be developed further in a larger cohort of buildings.

  8. Maintaining Equivalent Cut Scores for Small Sample Test Forms

    ERIC Educational Resources Information Center

    Dwyer, Andrew C.

    2016-01-01

    This study examines the effectiveness of three approaches for maintaining equivalent performance standards across test forms with small samples: (1) common-item equating, (2) resetting the standard, and (3) rescaling the standard. Rescaling the standard (i.e., applying common-item equating methodology to standard setting ratings to account for…

  9. NASA-STD-6001B Test 1 Upward Flame Propagation; Sample Length Impact on MOC Investigation

    NASA Technical Reports Server (NTRS)

    Harper, Susana Tapia; Juarez, Alfredo; Woods, Brenton L.; Beeson, Harold D.

    2017-01-01

    Understanding the combustion behavior of materials in the elevated oxygen environments of habitable spacecraft is of utmost importance to crew safety and mission success. Currently, certification for unrestricted flight usage of a material with respect to flammability involves passing the Upward Flame Propagation Test of NASA-STD-6001B (Test 1). This test evaluates materials in a standardized test configuration for two failure criteria: self-extinguishment within 15 cm (6 in.) and the propensity of flame propagation by means of flaming material transfer. By the NASA standard, full-length samples are 30 cm (12 in.) in length; however, factors independent of the test method such as limited material availability or various nonstandard test configurations limit the full pretest sample lengths available for test. This paper characterizes the dependence, if any, of pretest sample length on NASA-STD-6001B Test 1 results. Testing was performed using the Maximum Oxygen Concentration (MOC) Threshold Method to obtain a data set for each sample length tested. In addition, various material types, including cloth (Nomex), foam (TA-301) and solids (Ultem), were tested to investigate potential effects of test specimen types. Though additional data needs to be generated to provide statistical confidence, preliminary findings are that use of variable sample lengths has minimal impact on NASA-STD-6001B flammability performance and MOC determination.

  10. Triage of HR-HPV positive women with minor cytological abnormalities: a comparison of mRNA testing, HPV DNA testing, and repeat cytology using a 4-year follow-up of a population-based study.

    PubMed

    Persson, Maria; Elfström, K Miriam; Brismar Wendel, Sophia; Weiderpass, Elisabete; Andersson, Sonia

    2014-01-01

    Expression of the viral E6/E7 oncogenes of high-risk human papillomaviruses (HR-HPV) is necessary for malignant conversion and maintenance in cervical tissue. In order to determine whether HR-HPV E6/E7 mRNA testing more effectively predicts precancerous lesions and invasive cervical cancer than HR-HPV DNA testing, we aimed to compare triage using HR-HPV E6/E7 mRNA testing by APTIMA HPV Assay (APTIMA) to HPV16 DNA testing, HPV16/18 DNA testing, and repeat cytology. Liquid-based (PreservCyt) cell samples were obtained from HR-HPV-positive women diagnosed with atypical squamous cells of undetermined significance (ASCUS) and low-grade squamous intraepithelial lesions (LSIL) within the framework of the population-based cervical cancer screening program in Stockholm, Sweden. Samples were tested for HR-HPV E6/E7 mRNA by APTIMA (Gene-Probe Inc., San Diego, CA, USA). Women were followed up for 4 years after the index cytology via medical and laboratory records, and the Stockholm Oncology Center. Nine of 25 (36%) women in the ASCUS group, and 64 of 180 (36%) women in the LSIL group developed cervical intraepithelial neoplasia (CIN) grade 2 or worse during 4 years of follow-up. 162 (74%) women were APTIMA-positive, and APTIMA had the highest sensitivity to predict CIN2 or worse and CIN3 or worse in the ASCUS (77.8% and 100%) and LSIL (78.1 and 75.8%) groups, although specificity was insufficient (<50%). HPV16 DNA testing and repeat cytology were more specific than APTIMA. The results of this population-based study with comprehensive follow-up support the use of APTIMA as a triage test for women with ASCUS. More focused investigation is required for women with LSIL.

  11. Triage of HR-HPV Positive Women with Minor Cytological Abnormalities: A Comparison of mRNA Testing, HPV DNA Testing, and Repeat Cytology Using a 4-Year Follow-Up of a Population-Based Study

    PubMed Central

    Persson, Maria; Elfström, K. Miriam; Brismar Wendel, Sophia; Weiderpass, Elisabete; Andersson, Sonia

    2014-01-01

    Objective Expression of the viral E6/E7 oncogenes of high-risk human papillomaviruses (HR-HPV) is necessary for malignant conversion and maintenance in cervical tissue. In order to determine whether HR-HPV E6/E7 mRNA testing more effectively predicts precancerous lesions and invasive cervical cancer than HR-HPV DNA testing, we aimed to compare triage using HR-HPV E6/E7 mRNA testing by APTIMA HPV Assay (APTIMA) to HPV16 DNA testing, HPV16/18 DNA testing, and repeat cytology. Methods Liquid-based (PreservCyt) cell samples were obtained from HR-HPV-positive women diagnosed with atypical squamous cells of undetermined significance (ASCUS) and low-grade squamous intraepithelial lesions (LSIL) within the framework of the population-based cervical cancer screening program in Stockholm, Sweden. Samples were tested for HR-HPV E6/E7 mRNA by APTIMA (Gene-Probe Inc., San Diego, CA, USA). Women were followed up for 4 years after the index cytology via medical and laboratory records, and the Stockholm Oncology Center. Results Nine of 25 (36%) women in the ASCUS group, and 64 of 180 (36%) women in the LSIL group developed cervical intraepithelial neoplasia (CIN) grade 2 or worse during 4 years of follow-up. 162 (74%) women were APTIMA-positive, and APTIMA had the highest sensitivity to predict CIN2 or worse and CIN3 or worse in the ASCUS (77.8% and 100%) and LSIL (78.1 and 75.8%) groups, although specificity was insufficient (<50%). HPV16 DNA testing and repeat cytology were more specific than APTIMA. Conclusion The results of this population-based study with comprehensive follow-up support the use of APTIMA as a triage test for women with ASCUS. More focused investigation is required for women with LSIL. PMID:24587193

  12. Evaluation of positive and false-positive results in syphilis screening of blood donors in Rio de Janeiro, Brazil.

    PubMed

    Sandes, V S; Silva, S G C; Motta, I J F; Velarde, L G C; de Castilho, S R

    2017-06-01

    We propose to analyse the positive and false-positive results of treponemal and nontreponemal tests in blood donors from Brazil and to evaluate possible factors associated with the results of treponemal tests. Treponemal tests have been used widely for syphilis screening in blood banks. The introduction of these tests in donor screening has caused an impact and a loss of donors who need to be assessed. This was a retrospective cross-sectional study of syphilis screening and confirmatory test results of blood donors that were obtained before and after adopting a chemiluminescent immunoassay (CLIA). A comparative analysis was performed using a second sample drawn from positive donors. The possible factors associated with CLIA-positive or CLIA-false-positive results were investigated in a subgroup. Statistical tests were used to compare the proportions and adjusted estimates of association. The reactivity rate increased from 1·01% (N = 28 158) to 2·66% (N = 25 577) after introducing the new test. Among Venereal Disease Research Laboratory (VDRL)- and CLIA-confirmed results, the false-positive rates were 40·5% (N = 180) and 37·4% (N = 359), respectively (P = 0·5266). Older donors (OR = 1·04; P = 0·0010) and donors with lower education levels (OR = 6·59; P = 0·0029) were associated with a higher risk of positivity for syphilis. CLIA represents an improvement in blood bank serological screening. However, its use in a healthy population appears to result in high rates of false positives. Identifying which characteristics can predict false positives, however, remains a challenge. © 2017 British Blood Transfusion Society.

  13. Which factors may affect the willingness to take the HIV test? A research on Italian adults' sample.

    PubMed

    Mancini, Tiziana; Foà, Chiara

    2013-09-01

    Background and aim. Why people do not take the HIV test? The literature on the health-related behaviors associated with HIV infection has highlighted the role played by socio-demographical, behavioral, and cognitive variables. Less often has been studies the impact of psychosocial and normative factors that can affect willingness to test HIV. The aim of this study was to investigate which were the main psycho-social factors that promote/inhibit the intention to take the HIV test. Method. A questionnaire was submitted to a sample of 775 Italian adults (50. 7% female; mean age = 37.24; SD = 10.94; range 17 - 66 years). Results. Logistic Regression Analysis shown that age, risk behaviors, and personal concern are significantly predictors of the intention even if a positive attitude towards HIV test is the strongest predictor. Results showed also that the normative component of attitude (perception of social disapproval) and emotional component (shame and embarrassment) discouraged people from taking the test, while the cognitive-rational component did not. Conclusions. Are the perception of social disapproval by "significant others" and the social emotions of shame and embarrassment that discourage people from taking the test. Implications will be discussed.

  14. Tests of Independence in Contingency Tables with Small Samples: A Comparison of Statistical Power.

    ERIC Educational Resources Information Center

    Parshall, Cynthia G.; Kromrey, Jeffrey D.

    1996-01-01

    Power and Type I error rates were estimated for contingency tables with small sample sizes for the following four types of tests: (1) Pearson's chi-square; (2) chi-square with Yates's continuity correction; (3) the likelihood ratio test; and (4) Fisher's Exact Test. Various marginal distributions, sample sizes, and effect sizes were examined. (SLD)

  15. Pilot evaluation of the Computer-Based Assessment for Sampling Personal Characteristics test.

    PubMed

    Shipper, Edward S; Mazer, Laura M; Merrell, Sylvia Bereknyei; Lin, Dana T; Lau, James N; Melcher, Marc L

    2017-07-01

    High attrition rates hint at deficiencies in the resident selection process. The evaluation of personal characteristics representative of success is difficult. Here, we evaluate a novel tool for assessing personal characteristics. To evaluate feasibility, we used an anonymous voluntary survey questionnaire offered to study participants before and after contact with the CASPer test. To evaluate the CASPer test as a predictor of success, we compared CASPer test assessments of personal characteristics versus traditional faculty assessment of personal characteristics with applicant rank list position. All applicants (n = 77) attending an in-person interview for general surgery residency, and all faculty interviewers (n = 34) who reviewed these applications were invited to participate. Among applicants, 84.4% of respondents (65 of 77) reported that a requirement to complete the CASPer test would have no bearing or would make them more likely to apply to the program (mean = 3.30, standard deviation = 0.96). Among the faculty, 62.5% respondents (10 of 16) reported that the same condition would have no bearing or would make applicants more likely to apply to the program (mean = 3.19, standard deviation = 1.33). The Spearman's rank-order correlation coefficients for the relationships between traditional faculty assessment of personal characteristics and applicant rank list position, and novel CASPer assessment of personal characteristics and applicant rank list position, were -0.45 (P = 0.033) and -0.41 (P = 0.055), respectively. The CASPer test may be feasibly implemented as component of the resident selection process, with the potential to predict applicant rank list position and improve the general surgery resident selection process. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Client characteristics and gender-specific correlates of testing HIV positive: a comparison of standalone center versus mobile outreach HIV testing and counseling in Botswana.

    PubMed

    Hood, Julia E; MacKellar, Duncan; Spaulding, Anne; Nelson, Rob; Mosiakgabo, Boingotlo; Sikwa, Bangwato; Puso, Innocentia; Raats, Jan; Loeto, Peter; Alwano, Mary Grace; Monyatsi, Blessed

    2012-10-01

    Using data from Botswana's largest HIV testing and counseling (HTC) provider, Tebelopele, we evaluate populations served and gender-specific correlates of testing HIV-positive among clients of two programs: standalone centers and outreach testing. Client records from January to June 2007 (n = 47,890) were evaluated by HTC program and gender. Bivariate and multivariate analyses were performed to identify demographic, testing, and risk-behavior variables associated with testing HIV-positive. Compared to outreach testing, standalone centers served proportionally more clients who were young, well-educated, unmarried, and HIV-infected; outreach testing reached an older, less-educated population. Age, educational attainment, marital status, couples testing, testing because of illness or discordant relationship, and nonuse of condoms (among young clients only) were consistently associated with testing HIV-positive, by HTC program and gender. Our evaluation suggests that Tebelopele standalone and outreach HTC programs serve different populations, and identifies strategies to reduce HIV infection risk and to improve uptake of HTC by HIV-infected, undiagnosed Batswana.

  17. Sampling design for groundwater solute transport: Tests of methods and analysis of Cape Cod tracer test data

    USGS Publications Warehouse

    Knopman, Debra S.; Voss, Clifford I.; Garabedian, Stephen P.

    1991-01-01

    Tests of a one-dimensional sampling design methodology on measurements of bromide concentration collected during the natural gradient tracer test conducted by the U.S. Geological Survey on Cape Cod, Massachusetts, demonstrate its efficacy for field studies of solute transport in groundwater and the utility of one-dimensional analysis. The methodology was applied to design of sparse two-dimensional networks of fully screened wells typical of those often used in engineering practice. In one-dimensional analysis, designs consist of the downstream distances to rows of wells oriented perpendicular to the groundwater flow direction and the timing of sampling to be carried out on each row. The power of a sampling design is measured by its effectiveness in simultaneously meeting objectives of model discrimination, parameter estimation, and cost minimization. One-dimensional models of solute transport, differing in processes affecting the solute and assumptions about the structure of the flow field, were considered for description of tracer cloud migration. When fitting each model using nonlinear regression, additive and multiplicative error forms were allowed for the residuals which consist of both random and model errors. The one-dimensional single-layer model of a nonreactive solute with multiplicative error was judged to be the best of those tested. Results show the efficacy of the methodology in designing sparse but powerful sampling networks. Designs that sample five rows of wells at five or fewer times in any given row performed as well for model discrimination as the full set of samples taken up to eight times in a given row from as many as 89 rows. Also, designs for parameter estimation judged to be good by the methodology were as effective in reducing the variance of parameter estimates as arbitrary designs with many more samples. Results further showed that estimates of velocity and longitudinal dispersivity in one-dimensional models based on data from only five

  18. Tilt angles and positive response of head-up tilt test in children with orthostatic intolerance.

    PubMed

    Lin, Jing; Wang, Yuli; Ochs, Todd; Tang, Chaoshu; Du, Junbao; Jin, Hongfang

    2015-01-01

    This study aimed at examining three tilt angle-based positive responses and the time to positive response in a head-up tilt test for children with orthostatic intolerance, and the psychological fear experienced at the three angles during head-up tilt test. A total of 174 children, including 76 boys and 98 girls, aged from 4 to 18 years old (mean 11.3±2.8 years old), with unexplained syncope, were randomly divided into three groups, to undergo head-up tilt test at the angles of 60°, 70° and 80°, respectively. The diagnostic rates and times were analysed, and Wong-Baker face pain rating scale was used to access the children's psychological fear. There were no significant differences in diagnostic rates of postural orthostatic tachycardia syndrome and vasovagal syncope at different tilt angles during the head-up tilt test (p>0.05). There was a significant difference, however, in the psychological fear at different tilt angles utilising the Kruskal-Wallis test (χ2=36.398, p<0.01). It was mildest at tilt angle 60° utilising the Kolmogorov-Smirnov test (p<0.01). A positive rank correlation was found between the psychological fear and the degree of tilt angle (r(s)=0.445, p<0.01). Positive response appearance time was 15.1±14.0 minutes at 60° for vasovagal syncope children. There was no significant difference in the time to positive response, at different tilt angles during the head-up tilt test for vasovagal syncope or for postural orthostatic tachycardia syndrome. Hence, it is suggested that a tilt angle of 60° and head-up tilt test time of 45 minutes should be suitable for children with vasovagal syncope.

  19. Evaluation of sampling frequency, window size and sensor position for classification of sheep behaviour.

    PubMed

    Walton, Emily; Casey, Christy; Mitsch, Jurgen; Vázquez-Diosdado, Jorge A; Yan, Juan; Dottorini, Tania; Ellis, Keith A; Winterlich, Anthony; Kaler, Jasmeet

    2018-02-01

    Automated behavioural classification and identification through sensors has the potential to improve health and welfare of the animals. Position of a sensor, sampling frequency and window size of segmented signal data has a major impact on classification accuracy in activity recognition and energy needs for the sensor, yet, there are no studies in precision livestock farming that have evaluated the effect of all these factors simultaneously. The aim of this study was to evaluate the effects of position (ear and collar), sampling frequency (8, 16 and 32 Hz) of a triaxial accelerometer and gyroscope sensor and window size (3, 5 and 7 s) on the classification of important behaviours in sheep such as lying, standing and walking. Behaviours were classified using a random forest approach with 44 feature characteristics. The best performance for walking, standing and lying classification in sheep (accuracy 95%, F -score 91%-97%) was obtained using combination of 32 Hz, 7 s and 32 Hz, 5 s for both ear and collar sensors, although, results obtained with 16 Hz and 7 s window were comparable with accuracy of 91%-93% and F -score 88%-95%. Energy efficiency was best at a 7 s window. This suggests that sampling at 16 Hz with 7 s window will offer benefits in a real-time behavioural monitoring system for sheep due to reduced energy needs.

  20. Evaluation of sampling frequency, window size and sensor position for classification of sheep behaviour

    PubMed Central

    Walton, Emily; Casey, Christy; Mitsch, Jurgen; Vázquez-Diosdado, Jorge A.; Yan, Juan; Dottorini, Tania; Ellis, Keith A.; Winterlich, Anthony

    2018-01-01

    Automated behavioural classification and identification through sensors has the potential to improve health and welfare of the animals. Position of a sensor, sampling frequency and window size of segmented signal data has a major impact on classification accuracy in activity recognition and energy needs for the sensor, yet, there are no studies in precision livestock farming that have evaluated the effect of all these factors simultaneously. The aim of this study was to evaluate the effects of position (ear and collar), sampling frequency (8, 16 and 32 Hz) of a triaxial accelerometer and gyroscope sensor and window size (3, 5 and 7 s) on the classification of important behaviours in sheep such as lying, standing and walking. Behaviours were classified using a random forest approach with 44 feature characteristics. The best performance for walking, standing and lying classification in sheep (accuracy 95%, F-score 91%–97%) was obtained using combination of 32 Hz, 7 s and 32 Hz, 5 s for both ear and collar sensors, although, results obtained with 16 Hz and 7 s window were comparable with accuracy of 91%–93% and F-score 88%–95%. Energy efficiency was best at a 7 s window. This suggests that sampling at 16 Hz with 7 s window will offer benefits in a real-time behavioural monitoring system for sheep due to reduced energy needs. PMID:29515862

  1. Assessment of rates of recanting and hair testing as a biological measure of drug use in a general population sample of young people.

    PubMed

    Taylor, Michelle; Sullivan, John; Ring, Susan M; Macleod, John; Hickman, Matthew

    2017-03-01

    We investigate the extent of and factors associated with denial of previously reported cannabis and other illicit drug use, and assess the potential of hair testing for measuring substance use in general population samples. Birth cohort study. United Kingdom, 1991-present. A total of 3643 participants who provided hair and self-report measures of cannabis and other illicit drug use in the Avon Longitudinal Study of Parents and Children (ALSPAC) at age 18 years. Denial of ever use of cannabis and other illicit drugs at age 18 following previously reported use. Positive hair drug tests for cannabis and other illicit drugs, and expected numbers of false positives and false negatives based on expected sensitivity and specificity. Cannabis and other illicit drug use was reported by 1223 and 393 individuals, respectively, before age 18 years. Of these 176 (14.4%) and 99 (25.2%), respectively, denied use at age 18. Denial of cannabis use decreased with the reporting of other substances and antisocial behaviour. Cannabis and other illicit drug use at age 18 was reported by 547 (22.5%) and 203 (8.4%) individuals, respectively. Of these, 111 (20.3%) and 13 (6.4%) were hair-positive for cannabis and other illicit drugs, respectively. Based on hair testing for cannabis use we expect 0 [95% confidence interval (CI) = 0-169] false positives and 394 (95% CI = 323-449) false negatives compared to observed 362 potential false positives and 436 potential false negatives based on self-report. In hair-positive individuals, reporting the use of other substances and antisocial behaviour decreased the odds of a negative self-report. Hair analysis provides an unreliable marker of substance use in general population samples. People who report more frequent substance use before age 18 are less likely to later deny previous substance use at age 18 than people who report occasional use. © 2016 The Authors. Addiction published by John Wiley & Sons Ltd on behalf of Society for the Study

  2. Assessment of rates of recanting and hair testing as a biological measure of drug use in a general population sample of young people

    PubMed Central

    Sullivan, John; Ring, Susan M.; Macleod, John; Hickman, Matthew

    2016-01-01

    Abstract Aims We investigate the extent of and factors associated with denial of previously reported cannabis and other illicit drug use, and assess the potential of hair testing for measuring substance use in general population samples. Design Birth cohort study. Setting United Kingdom, 1991–present. Participants A total of 3643 participants who provided hair and self‐report measures of cannabis and other illicit drug use in the Avon Longitudinal Study of Parents and Children (ALSPAC) at age 18 years. Measurements Denial of ever use of cannabis and other illicit drugs at age 18 following previously reported use. Positive hair drug tests for cannabis and other illicit drugs, and expected numbers of false positives and false negatives based on expected sensitivity and specificity. Findings Cannabis and other illicit drug use was reported by 1223 and 393 individuals, respectively, before age 18 years. Of these 176 (14.4%) and 99 (25.2%), respectively, denied use at age 18. Denial of cannabis use decreased with the reporting of other substances and antisocial behaviour. Cannabis and other illicit drug use at age 18 was reported by 547 (22.5%) and 203 (8.4%) individuals, respectively. Of these, 111 (20.3%) and 13 (6.4%) were hair‐positive for cannabis and other illicit drugs, respectively. Based on hair testing for cannabis use we expect 0 [95% confidence interval (CI) = 0–169] false positives and 394 (95% CI = 323–449) false negatives compared to observed 362 potential false positives and 436 potential false negatives based on self‐report. In hair‐positive individuals, reporting the use of other substances and antisocial behaviour decreased the odds of a negative self‐report. Conclusions Hair analysis provides an unreliable marker of substance use in general population samples. People who report more frequent substance use before age 18 are less likely to later deny previous substance use at age 18 than people who report occasional use. PMID

  3. Dynamic Stability Testing of the Genesis Sample Return Capsule

    NASA Technical Reports Server (NTRS)

    Cheatwood, F. McNeil; Winchenbach, Gerald L.; Hathaway, Wayne; Chapman, Gary

    2000-01-01

    This paper documents a series of free flight tests of a scale model of the Genesis Sample Return Capsule. These tests were conducted in the Aeroballistic Research Facility (ARF), located at Eglin AFB, FL, during April 1999 and were sponsored by NASA Langley Research Center. Because these blunt atmospheric entry shapes tend to experience small angle of attack dynamic instabilities (frequently leading to limit cycle motions), the primary purpose of the present tests was to determine the dynamic stability characteristics of the Genesis configuration. The tests were conducted over a Mach number range of 1.0 to 4.5. The results for this configuration indicate that the models were dynamically unstable at low angles of attack for all Mach numbers tested. At Mach numbers below 2.5, the models were also unstable at the higher angles of attack (above 15 deg), and motion amplitudes of up to 40 deg were experienced. Above Mach 2.5, the models were dynamically stable at the higher angles of attack.

  4. A comparative study of the typhidot (Dot-EIA) and Widal tests in blood culture positive cases of typhoid fever.

    PubMed

    Khoharo, Haji Khan

    2011-07-01

    Seventy-six blood culture positive typhoid cases and forty-eight controls were studied. The typhidot test was positive in 74 (97.36%) cases, with a sensitivity, specificity and positive predictive value of 96%, 89.5%, and 95%, respectively, compared to the Widal test which was positive in 56 (73.68%) cases with a sensitivity, specificity, and positive predictive value of 72%, 87%, and 87%, respectively (P = 0.001). In the control group, seven (14.5%) cases tested positive for the Widal test and two (4.16%) for the typhidot (P = 0.001), yielding the sensitivity and specificity for the Widal test and the typhidot test of 63% and 83%, and 85% and 97%, respectively. We conclude that the Dot-EIA (enzyme immunoassay; typhidot) is a more sensitive and specific test which is easy to perform and more reliable compared to the Widal test and that it is useful in early therapy.

  5. Group Systematic Desensitization Versus Covert Positive Reinforcement in the Reduction of Test Anxiety

    ERIC Educational Resources Information Center

    Kostka, Marion P.; Galassi, John P.

    1974-01-01

    The study compared modified versions of systematic desensitization and covert positive reinforcement to a no-treatment control condition in the reduction of test anxiety. On an anagrams performance test, the covert reinforcement and control groups were superior to the desensitization group. (Author)

  6. False-Positive Results after Environmental Pinworm PCR Testing due to Rhabditid Nematodes in Corncob Bedding

    PubMed Central

    Leblanc, Mathias; Berry, Kristina; Graciano, Sandy; Becker, Brandon; Reuter, Jon D

    2014-01-01

    Modern rodent colonies are housed in individually ventilated cages to protect the animals from contamination with adventitious pathogens. Standard health monitoring through soiled-bedding sentinels does not always detect infections, especially in the context of low pathogen prevalence. Recently proposed alternatives include analyzing environmental samples from the cages or rack exhaust by PCR to improve the detection of rodent pathogens but optimal sampling strategies have not yet been established for different microorganisms. Although generally very sensitive and specific, these molecular assays are not foolproof and subject to false-positive and –negative results and should always be interpreted cautiously with an overall understanding of the intrinsic controls and all the variables that may affect the results. Here, we report a limited Aspiculuris tetraptera outbreak in a mouse barrier facility that was detected by fecal PCR in sentinels and confirmed by fecal flotation and direct cecal examination of both sentinels and colony animals. The outbreak led to a widespread survey of all facilities for pinworms by using environmental PCR from ventilated rack exhaust plenums. Environmental PCR suggested an unexpected widespread contamination of all ventilated racks holding nonautoclaved cages, but results could not be confirmed in sentinel or colony animals by fecal flotation, cecal and colonic examination, or cage PCR testing. After additional investigation, the unexpected environmental PCR results were confirmed as false-positive findings due to the nonspecificity of the assay, leading to the amplification of rhabditid nematodes, which are not infectious in rodents but which contaminated the corncob bedding. PMID:25650980

  7. False-positive results after environmental pinworm PCR testing due to Rhabditid nematodes in Corncob bedding.

    PubMed

    Leblanc, Mathias; Berry, Kristina; Graciano, Sandy; Becker, Brandon; Reuter, Jon D

    2014-11-01

    Modern rodent colonies are housed in individually ventilated cages to protect the animals from contamination with adventitious pathogens. Standard health monitoring through soiled-bedding sentinels does not always detect infections, especially in the context of low pathogen prevalence. Recently proposed alternatives include analyzing environmental samples from the cages or rack exhaust by PCR to improve the detection of rodent pathogens but optimal sampling strategies have not yet been established for different microorganisms. Although generally very sensitive and specific, these molecular assays are not foolproof and subject to false-positive and -negative results and should always be interpreted cautiously with an overall understanding of the intrinsic controls and all the variables that may affect the results. Here, we report a limited Aspiculuris tetraptera outbreak in a mouse barrier facility that was detected by fecal PCR in sentinels and confirmed by fecal flotation and direct cecal examination of both sentinels and colony animals. The outbreak led to a widespread survey of all facilities for pinworms by using environmental PCR from ventilated rack exhaust plenums. Environmental PCR suggested an unexpected widespread contamination of all ventilated racks holding nonautoclaved cages, but results could not be confirmed in sentinel or colony animals by fecal flotation, cecal and colonic examination, or cage PCR testing. After additional investigation, the unexpected environmental PCR results were confirmed as false-positive findings due to the nonspecificity of the assay, leading to the amplification of rhabditid nematodes, which are not infectious in rodents but which contaminated the corncob bedding.

  8. Surface sampling concentration and reaction probe with controller to adjust sampling position

    DOEpatents

    Van Berkel, Gary J.; ElNaggar, Mariam S.

    2016-07-19

    A method of analyzing a chemical composition of a specimen is described. The method can include providing a probe comprising an outer capillary tube and an inner capillary tube disposed co-axially within the outer capillary tube, where the inner and outer capillary tubes define a solvent capillary and a sampling capillary in fluid communication with one another at a distal end of the probe; contacting a target site on a surface of a specimen with a solvent in fluid communication with the probe; maintaining a plug volume proximate a solvent-specimen interface, wherein the plug volume is in fluid communication with the probe; draining plug sampling fluid from the plug volume through the sampling capillary; and analyzing a chemical composition of the plug sampling fluid with an analytical instrument. A system for performing the method is also described.

  9. Testing for independence in J×K contingency tables with complex sample survey data.

    PubMed

    Lipsitz, Stuart R; Fitzmaurice, Garrett M; Sinha, Debajyoti; Hevelone, Nathanael; Giovannucci, Edward; Hu, Jim C

    2015-09-01

    The test of independence of row and column variables in a (J×K) contingency table is a widely used statistical test in many areas of application. For complex survey samples, use of the standard Pearson chi-squared test is inappropriate due to correlation among units within the same cluster. Rao and Scott (1981, Journal of the American Statistical Association 76, 221-230) proposed an approach in which the standard Pearson chi-squared statistic is multiplied by a design effect to adjust for the complex survey design. Unfortunately, this test fails to exist when one of the observed cell counts equals zero. Even with the large samples typical of many complex surveys, zero cell counts can occur for rare events, small domains, or contingency tables with a large number of cells. Here, we propose Wald and score test statistics for independence based on weighted least squares estimating equations. In contrast to the Rao-Scott test statistic, the proposed Wald and score test statistics always exist. In simulations, the score test is found to perform best with respect to type I error. The proposed method is motivated by, and applied to, post surgical complications data from the United States' Nationwide Inpatient Sample (NIS) complex survey of hospitals in 2008. © 2015, The International Biometric Society.

  10. Power and sample size evaluation for the Cochran-Mantel-Haenszel mean score (Wilcoxon rank sum) test and the Cochran-Armitage test for trend.

    PubMed

    Lachin, John M

    2011-11-10

    The power of a chi-square test, and thus the required sample size, are a function of the noncentrality parameter that can be obtained as the limiting expectation of the test statistic under an alternative hypothesis specification. Herein, we apply this principle to derive simple expressions for two tests that are commonly applied to discrete ordinal data. The Wilcoxon rank sum test for the equality of distributions in two groups is algebraically equivalent to the Mann-Whitney test. The Kruskal-Wallis test applies to multiple groups. These tests are equivalent to a Cochran-Mantel-Haenszel mean score test using rank scores for a set of C-discrete categories. Although various authors have assessed the power function of the Wilcoxon and Mann-Whitney tests, herein it is shown that the power of these tests with discrete observations, that is, with tied ranks, is readily provided by the power function of the corresponding Cochran-Mantel-Haenszel mean scores test for two and R > 2 groups. These expressions yield results virtually identical to those derived previously for rank scores and also apply to other score functions. The Cochran-Armitage test for trend assesses whether there is an monotonically increasing or decreasing trend in the proportions with a positive outcome or response over the C-ordered categories of an ordinal independent variable, for example, dose. Herein, it is shown that the power of the test is a function of the slope of the response probabilities over the ordinal scores assigned to the groups that yields simple expressions for the power of the test. Copyright © 2011 John Wiley & Sons, Ltd.

  11. Reliability of Measurement of Glenohumeral Internal Rotation, External Rotation, and Total Arc of Motion in 3 Test Positions

    PubMed Central

    Kevern, Mark A.; Beecher, Michael; Rao, Smita

    2014-01-01

    Context: Athletes who participate in throwing and racket sports consistently demonstrate adaptive changes in glenohumeral-joint internal and external rotation in the dominant arm. Measurements of these motions have demonstrated excellent intrarater and poor interrater reliability. Objective: To determine intrarater reliability, interrater reliability, and standard error of measurement for shoulder internal rotation, external rotation, and total arc of motion using an inclinometer in 3 testing procedures in National Collegiate Athletic Association Division I baseball and softball athletes. Design: Cross-sectional study. Setting: Athletic department. Patients or Other Participants Thirty-eight players participated in the study. Shoulder internal rotation, external rotation, and total arc of motion were measured by 2 investigators in 3 test positions. The standard supine position was compared with a side-lying test position, as well as a supine test position without examiner overpressure. Results: Excellent intrarater reliability was noted for all 3 test positions and ranges of motion, with intraclass correlation coefficient values ranging from 0.93 to 0.99. Results for interrater reliability were less favorable. Reliability for internal rotation was highest in the side-lying position (0.68) and reliability for external rotation and total arc was highest in the supine-without-overpressure position (0.774 and 0.713, respectively). The supine-with-overpressure position yielded the lowest interrater reliability results in all positions. The side-lying position had the most consistent results, with very little variation among intraclass correlation coefficient values for the various test positions. Conclusions: The results of our study clearly indicate that the side-lying test procedure is of equal or greater value than the traditional supine-with-overpressure method. PMID:25188316

  12. A sample-to-result system for blood coagulation tests on a microfluidic disk analyzer

    PubMed Central

    Lin, Chia-Hui; Liu, Cheng-Yuan; Shih, Chih-Hsin; Lu, Chien-Hsing

    2014-01-01

    In this report, we describe in detail a microfluidic analyzer, which is able to conduct blood coagulation tests using whole blood samples. Sample preparation steps, such as whole blood aliquoting and metering, plasma separation, decanting, and mixing with reagents were performed in sequence through microfluidic functions integrated on a disk. Both prothrombin time (PT) and activated partial thromboplastin time (aPTT) were carried out on the same platform and the test results can be reported in 5 min. Fifty clinical samples were tested for both PT and aPTT utilizing the microfluidic disk analyzer and the instrument used in hospitals. The test results showed good correlation and agreement between the two instruments. PMID:25332733

  13. The Effect of the Position of an Item within a Test on the Item Difficulty Value.

    ERIC Educational Resources Information Center

    Rubin, Lois S.; Mott, David E. W.

    An investigation of the effect on the difficulty value of an item due to position placement within a test was made. Using a 60-item operational test comprised of 5 subtests, 60 items were placed as experimental items on a number of spiralled test forms in three different positions (first, middle, last) within the subtest composed of like items.…

  14. Finkelstein's test: a descriptive error that can produce a false positive.

    PubMed

    Elliott, B G

    1992-08-01

    Over the last three decades an error in performing Finkelstein's test has crept into the English literature in both text books and journals. This error can produce a false-positive, and if relied upon, a wrong diagnosis can be made, leading to inappropriate surgery.

  15. PAL-XFEL cavity beam position monitor pick-up design and beam test

    NASA Astrophysics Data System (ADS)

    Lee, Sojeong; Park, Young Jung; Kim, Changbum; Kim, Seung Hwan; Shin, Dong Cheol; Han, Jang-Hui; Ko, In Soo

    2016-08-01

    As an X-ray Free Electron Laser, PAL-XFEL is about to start beam commissioning. X-band cavity beam position monitor (BPM) is used in the PAL-XFEL undulator beam line. Prototypes of cavity BPM pick-up were designed and fabricated to test the RF characteristics. Also, the beam test of a cavity BPM pick-up was done in the Injector Test Facility (ITF). In the beam test, the raw signal properties of the cavity BPM pick-up were measured at a 200 pC bunch charge. According to the RF test and beam test results, the prototype cavity BPM pick-up design was confirmed to meet the requirements of the PAL-XFEL cavity BPM system.

  16. Characterization of human organ donors testing positive for type 1 diabetes-associated autoantibodies

    PubMed Central

    Wiberg, A; Granstam, A; Ingvast, S; Härkönen, T; Knip, M; Korsgren, O; Skog, O

    2015-01-01

    In this study we aim to describe the characteristics of non-diabetic organ donors with circulating diabetes-associated autoantibodies collected within the Nordic Network for Islet Transplantation. One thousand and thirty organ donors have been screened in Uppsala for antibodies against glutamic acid decarboxylase (GADA) and islet antigen-2 (IA-2A). The 32 non-diabetic donors that tested positive for GADA (3·3% of all non-diabetic donors) were studied in more detail, together with 32 matched controls. Mean age among the autoantibody-positive donors was 52·6 (range 21–74), family history of type 1 diabetes (T1D) was unknown, and no donor was genetically predisposed for T1D regarding the human leucocyte antigen (HLA) locus. Subjects were analysed for islet cell antibodies (ICA), insulin autoantibodies (IAA) and zinc transporter 8 antibodies (ZnT8A), and pancreas morphology and clinical data were examined. Eight non-diabetic donors tested positive for two antibodies and one donor tested positive for four antibodies. No insulitis or other signs of a diabetic process were found in any of the donors. While inflammatory cells were present in all donors, subjects with high GADA titres had significantly higher CD45 cell numbers in exocrine tissue than controls. The extent of fibrosis was more pronounced in autoantibody-positive donors, even in subjects with lower GADA titres. Notably, it is possible that events not related directly to T1D (e.g. subclinical pancreatitis) may induce autoantibodies in some cases. PMID:26313035

  17. 40 CFR 80.1347 - What are the sampling and testing requirements for refiners and importers?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Benzene Sampling, Testing and Retention Requirements § 80.1347 What are the sampling and testing... benzene requirements of this subpart, except as modified by paragraphs (a)(2), (a)(3) and (a)(4) of this... benzene concentration for compliance with the requirements of this subpart. (ii) Independent sample...

  18. 40 CFR 80.1347 - What are the sampling and testing requirements for refiners and importers?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Benzene Sampling, Testing and Retention Requirements § 80.1347 What are the sampling and testing... benzene requirements of this subpart, except as modified by paragraphs (a)(2), (a)(3) and (a)(4) of this... benzene concentration for compliance with the requirements of this subpart. (ii) Independent sample...

  19. [Value of positive auto controls in the gel centrifugation method].

    PubMed

    Eichler, H; Kretschmer, V

    1994-01-01

    We studied 97 samples of patients being positive in the autocontrol of the indirect antiglobulin test (IAT) in the gel system (DiaMed). In 83.2%, retesting with monospecific anti-IgG serum gave also positive results, due to a specific phenomenon caused, for example, by drug-specific antibodies (AB), warm auto-AB or allo-AB. In contrast, only 52.9% of the samples retested by the standard tube technique with polyspecific antiglobulin serum reacted positive. Only in 6 patients slightly increased cold agglutinins could be detected. None of the investigated patients showed any clinical or laboratory signs of hemolysis except one with pernicious anemia. We conclude that positive results of the autocontrol in the gel IAT should be confirmed by an additional DAT in the tube technique. If this second test shows a negative result, transfusions can take place without any restrictions.

  20. Diagnostic-test evaluation of immunoassays for anti-Toxoplasma gondii IgG antibodies in a random sample of Mexican population.

    PubMed

    Caballero-Ortega, Heriberto; Castillo-Cruz, Rocío; Murieta, Sandra; Ortíz-Alegría, Luz Belinda; Calderón-Segura, Esther; Conde-Glez, Carlos J; Cañedo-Solares, Irma; Correa, Dolores

    2014-05-14

    There are few articles on evaluation of Toxoplasma gondii serological tests. Besides, commercially available tests are not always useful and are expensive for studies in open population. The aim of this study was to evaluate in-house ELISA and western blot for IgG antibodies in a representative sample of people living in Mexico. Three hundred and five serum samples were randomly selected from two national seroepidemiological survey banks; they were taken from men and women of all ages and from all areas of the country. ELISA cut-off was established using the mean plus three standard deviations of negative samples. Western blots were analysed by two experienced technicians and positivity was established according to the presence of at least three diagnostic bands. A commercial ELISA kit was used as a third test. Two reference standards were built up: one using concordant results of two assays leaving the evaluated test out and the other in which the evaluated test was included (IN) with at least two concordant results to define diagnosis. the lowest values of diagnostic parameters were obtained with the OUT reference standards: in-house ELISA had 96.9% sensitivity, 62.1% specificity, 49.6% PPV, 98.1% NPV and 71.8% accuracy, while western blot presented 81.8%, 89.7%, 84.0%, 88.2% and 86.6% values and the best kappa coefficient (0.72-0.82). The in-house ELISA is useful for screening people of Mexico, due to its high sensitivity, while western blot may be used to confirm diagnosis. These techniques might prove useful in other Latin American countries.

  1. Estimating the positive predictive value of opportunistic population testing for gonorrhoea as part of the English Chlamydia Screening Programme.

    PubMed

    Fowler, T; Edeghere, O; Inglis, N; Bradshaw, S

    2013-03-01

    Advances in technology have raised the possibility of including gonorrhoea testing as part of chlamydia screening. In England this is recommended only where the positive predictive value (PPV) of the test is ≥90%. This study assessed the PPV for gonorrhoea testing using routine testing data. Routine data (including gonorrhoea testing) from the Greater Manchester Chlamydia Screening Programme (GMCSP) in 2009/2010, were used to estimate the PPV for gonorrhoea testing. Of those screened, 0.3% (59/18044) of men and 0.4% (174/41873) of women tested positive for gonorrhoea. The PPV was 82.3% in women and 73.6% in men, in those who also tested positive for chlamydia. For women and men testing negative for chlamydia the PPV for a positive gonorrhoea test was incalculable. The low PPV observed in most groups suggests that where population testing for gonorrhoea occurs there is a need for further confirmatory testing of positive results before treatment decisions are made. Clinicians should be aware of screening test result limitations in this context.

  2. A cryogenic tensile testing apparatus for micro-samples cooled by miniature pulse tube cryocooler

    NASA Astrophysics Data System (ADS)

    Chen, L. B.; Liu, S. X.; Gu, K. X.; Zhou, Y.; Wang, J. J.

    2015-12-01

    This paper introduces a cryogenic tensile testing apparatus for micro-samples cooled by a miniature pulse tube cryocooler. At present, tensile tests are widely applied to measure the mechanical properties of materials; most of the cryogenic tensile testing apparatus are designed for samples with standard sizes, while for non-standard size samples, especially for microsamples, the tensile testing cannot be conducted. The general approach to cool down the specimens for tensile testing is by using of liquid nitrogen or liquid helium, which is not convenient: it is difficult to keep the temperature of the specimens at an arbitrary set point precisely, besides, in some occasions, liquid nitrogen, especially liquid helium, is not easily available. To overcome these limitations, a cryogenic tensile testing apparatus cooled by a high frequency pulse tube cryocooler has been designed, built and tested. The operating temperatures of the developed tensile testing apparatus cover from 20 K to room temperature with a controlling precision of ±10 mK. The apparatus configurations, the methods of operation and some cooling performance will be described in this paper.

  3. Stress and anxiety effects on positive skin test responses in young adults with allergic rhinitis.

    PubMed

    Heffner, Kathi L; Kiecolt-Glaser, Janice K; Glaser, Ronald; Malarkey, William B; Marshall, Gailen D

    2014-07-01

    Anxiety and psychological stress affect allergy-related immune function. How these relations influence the evaluations of patients with allergic rhinitis is unknown. To examine whether anxiety and stress exposure affect skin prick test (SPT) responses to common allergens for which patients with atopy showed no prior positive SPT response. Patients with allergic rhinitis, evidenced by clinical history and SPT results, were admitted twice to a hospital research unit for 4 hours. In a crossover design, SPT wheals were assessed before and after the Trier Social Stress Test and then the following morning; for comparison, SPT wheals were assessed before and after a laboratory session without a stressor. Analyses focused on wheal responses for common allergens that tested negative (wheal size <3 mm larger than saline) from SPTs performed at multiple baseline assessments. After the Trier Social Stress Test, more anxious patients with atopy had a higher incidence of positive SPT reactions to antigens that previously tested negative. Anxiety was unrelated to positive SPT incidence under nonstressful conditions. Based on clinical symptom reports, newly positive SPT reactions after the stressor were apparently corrections of previously false-negative SPT reactions. The SPT wheal responses for allergens previously testing negative were enhanced after a stressor. Histamine (positive control) or saline (negative control) SPT responses were not affected. A laboratory stressor affected allergen SPT responses in more anxious patients with allergic rhinitis. In addition to clinical history, assessment of anxiety and current stress at the time of the SPT may provide valuable information about a patient's allergic status and aid in clinical decision making. Copyright © 2014 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  4. Center not liable for defamation from false-positive hepatitis test.

    PubMed

    1997-04-18

    The Nebraska Court of Appeals ruled that [name removed] does not have a cause of action against the Lincoln Plasma Center in Lincoln, NE. The center blacklisted him as a carrier of hepatitis B virus; subsequent tests proved [name removed] was uninfected. [Name removed], a paid plasma donator, was placed on an ineligible list after he tested positive for the hepatitis B surface antigen. [Name removed] sued, alleging that Lincoln defamed him by publishing false information to blood banks about his eligibility to donate. The Court of Appeals upheld a trial court's directed verdict because there was no evidence that the plasma center acted in malice.

  5. Yoga and positive body image: A test of the Embodiment Model.

    PubMed

    Mahlo, Leeann; Tiggemann, Marika

    2016-09-01

    The study aimed to test the Embodiment Model of Positive Body Image (Menzel & Levine, 2011) within the context of yoga. Participants were 193 yoga practitioners (124 Iyengar, 69 Bikram) and 127 university students (non-yoga participants) from Adelaide, South Australia. Participants completed questionnaire measures of positive body image, embodiment, self-objectification, and desire for thinness. Results showed yoga practitioners scored higher on positive body image and embodiment, and lower on self-objectification than non-yoga participants. In support of the embodiment model, the relationship between yoga participation and positive body image was serially mediated by embodiment and reduced self-objectification. Although Bikram practitioners endorsed appearance-related reasons for participating in yoga more than Iyengar practitioners, there were no significant differences between Iyengar and Bikram yoga practitioners on body image variables. It was concluded that yoga is an embodying activity that can provide women with the opportunity to cultivate a favourable relationship with their body. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Chi-Squared Test of Fit and Sample Size-A Comparison between a Random Sample Approach and a Chi-Square Value Adjustment Method.

    PubMed

    Bergh, Daniel

    2015-01-01

    Chi-square statistics are commonly used for tests of fit of measurement models. Chi-square is also sensitive to sample size, which is why several approaches to handle large samples in test of fit analysis have been developed. One strategy to handle the sample size problem may be to adjust the sample size in the analysis of fit. An alternative is to adopt a random sample approach. The purpose of this study was to analyze and to compare these two strategies using simulated data. Given an original sample size of 21,000, for reductions of sample sizes down to the order of 5,000 the adjusted sample size function works as good as the random sample approach. In contrast, when applying adjustments to sample sizes of lower order the adjustment function is less effective at approximating the chi-square value for an actual random sample of the relevant size. Hence, the fit is exaggerated and misfit under-estimated using the adjusted sample size function. Although there are big differences in chi-square values between the two approaches at lower sample sizes, the inferences based on the p-values may be the same.

  7. Time-to-positivity, type of culture media and oxidase test performed on positive blood culture vials to predict Pseudomonas aeruginosa in patients with Gram-negative bacilli bacteraemia.

    PubMed

    Cobos-Triguero, N; Zboromyrska, Y; Morata, L; Alejo, I; De La Calle, C; Vergara, A; Cardozo, C; Arcas, M P; Soriano, A; Marco, F; Mensa, J; Almela, M; Martínez, J A

    2017-02-01

    The aim of this study was to determine the usefulness of oxidase test and time-to-positivity (TTP) in aerobic and anaerobic blood culture vials to detect the presence of Pseudomonas aeruginosa in patients with Gram-negative bacilli (GNB) bacteraemia. TTP was recorded for each aerobic and anaerobic blood culture vial of monomicrobial bacteraemia due to GNB. Oxidase test was performed in a pellet of the centrifuged content of the positive blood culture. An algorithm was developed in order to perform the oxidase test efficiently taking into account TTP and type of vial. A total of 341 episodes of GNB bacteraemia were analysed. Sensitivity, specificity, positive predictive value and negative predictive value of the oxidase test performed on positive vials with GNB to predict P. aeruginosa were 95%, 99%, 91%, and 99%, respectively. When growth was first or exclusively detected in anaerobic vials, P. aeruginosa was never identified hence the performance of the oxidase test could be avoided. When growth was only or first detected in aerobic vials, a TTP≥8h predicted P. aeruginosa in 37% or cases (63 of 169), therefore oxidase test is highly recommended. Oxidase test performed onto positive blood culture vials previously selected by TTP and type of vials is an easy and inexpensive way to predict P. aeruginosa. In most cases, this can lead to optimization of treatment in less than 24 hours.

  8. Feasibility of self-sampling and human papillomavirus testing for cervical cancer screening in First Nation women from Northwest Ontario, Canada: a pilot study

    PubMed Central

    Moeller, Helle; Severini, Alberto; Weaver, Bruce; Escott, Nicholas; Bell, Crystal; Crawford, Sandra; Bannon, Diane; Paavola, Natalie

    2011-01-01

    Background The incidence of cervical cancer is up to sixfold higher among First Nation women in Canada than in the general population. This is probably due to lower participation rates in cervical cancer prevention programmes. Objective To raise screening participation in this underserved population by launching an alternative approach to (Pap)anicolaou testing in a clinic—namely, vaginal self-sampling followed by human papillomavirus (HPV) diagnostics. Methods Good relationships were established with a First Nation community of the Northern Superior region in Northwest Ontario, and then 49 community women, aged 25–59, were recruited, who provided a vaginal self-sample and answered a questionnaire. Frequency distributions and cross-tabulations were used to summarise the data. Associations between categorical variables were assessed using the χ2 test of association, or the Goodman–Kruskal γ if both variables had ordered categories. Self-collected samples were tested for integrity and HPV using optimised molecular biological methods. Results The majority of participants (87.2%) were amenable to future HPV screening by self-sampling. This finding was independent of age, educational level and a previous history of abnormal Pap tests. Interestingly, the preferred way to learn about sexual health remained through interaction with healthcare professionals. As defined by the presence of a housekeeping gene, self-sample integrity was high (96%). Using polymerase chain reaction-based Luminex typing, the overall HPV positivity was 28.6% (ie, with either a low- or high-risk type) and 16.3% were infected with a high-risk type such as HPV16. Conclusion In this pilot study of First Nation women, self-sampling and HPV testing was well received and self-sample quality was excellent. A larger survey to be conducted in other Northern Superior communities in Northwest Ontario will determine whether this approach could become a viable screening strategy for First Nation women

  9. Autonomous site selection and instrument positioning for sample acquisition

    NASA Astrophysics Data System (ADS)

    Shaw, A.; Barnes, D.; Pugh, S.

    The European Space Agency Aurora Exploration Program aims to establish a European long-term programme for the exploration of Space, culminating in a human mission to space in the 2030 timeframe. Two flagship missions, namely Mars Sample Return and ExoMars, have been proposed as recognised steps along the way. The Exomars Rover is the first of these flagship missions and includes a rover carrying the Pasteur Payload, a mobile exobiology instrumentation package, and the Beagle 2 arm. The primary objective is the search for evidence of past or present life on mars, but the payload will also study the evolution of the planet and the atmosphere, look for evidence of seismological activity and survey the environment in preparation for future missions. The operation of rovers in unknown environments is complicated, and requires large resources not only on the planet but also in ground based operations. Currently, this can be very labour intensive, and costly, if large teams of scientists and engineers are required to assess mission progress, plan mission scenarios, and construct a sequence of events or goals for uplink. Furthermore, the constraints in communication imposed by the time delay involved over such large distances, and line-of-sight required, make autonomy paramount to mission success, affording the ability to operate in the event of communications outages and be opportunistic with respect to scientific discovery. As part of this drive to reduce mission costs and increase autonomy the Space Robotics group at the University of Wales, Aberystwyth is researching methods of autonomous site selection and instrument positioning, directly applicable to the ExoMars mission. The site selection technique used builds on the geometric reasoning algorithms used previously for localisation and navigation [Shaw 03]. It is proposed that a digital elevation model (DEM) of the local surface, generated during traverse and without interaction from ground based operators, can be

  10. Hepatitis C Testing

    PubMed Central

    Rochlani, Maya; Lewis, Jessica H.; Ramsey, Glenn E.; Bontempo, Franklin A.; Shah, Gunjan; Bowman, Rebecca A.; van Thiel, David H.; Starzl, Thomas E.

    2010-01-01

    Plasma samples from 1,182 patients undergoing primary liver transplantation were tested for anti-hepatitis C (HCV) virus by two methods: Ortho HCV ELISA Test System (EIA) and Chiron RIBA HCV Test System (RIBA II). The EIA results, 0 or +, were recorded first, followed by RIBA results, N = negative, P = positive, or I = indeterminate. Concordant results—0N, + P, + I—were found in 1,076 (91%), and discordant results were found in 106 (9%). The EIA optical density did not relate to concordant or discordant results. Band patterns were described by stating the band position (1, 2, 3, or 4) and insetting a dash (−) if no band was visualized. Most + P samples fell into two patterns: 47% showed all four bands, pattern 1234, and 15% showed the two-band pattern, 34. When the EIA was negative, 0P, the opposite was seen: 8% showed the 1234 pattern and 81% showed the 34 pattern. There were 226 samples that formed bands (+ P, 149; 0P, 31; + I, 15; 0I, 31). The frequency of bands was as follows: 4, 32%; 3, 31%; 2, 19%; and 1, 18%. Band 2 and the EIA test detected antibodies to the same c100-3 fragment and showed 74% concordance. No explanation is apparent for the lower concordance rate here than that between the EIA test and bands 3 = 96% or 4 = 88%. The EIA and RIBA II tests, together with positive liver function tests and abnormal tissue pathologic findings, provide a basis for the diagnosis of HCV. PMID:1377442

  11. Development and testing of a magnetic position sensor system for automotive and avionics applications

    NASA Astrophysics Data System (ADS)

    Jacobs, Bryan C.; Nelson, Carl V.

    2001-08-01

    A magnetic sensor system has been developed to measure the 3-D location and orientation of a rigid body relative to an array of magnetic dipole transmitters. A generalized solution to the measurement problem has been formulated, allowing the transmitter and receiver parameters (position, orientation, number, etc.) to be optimized for various applications. Additionally, the method of images has been used to mitigate the impact of metallic materials in close proximity to the sensor. The resulting system allows precise tracking of high-speed motion in confined metal environments. The sensor system was recently configured and tested as an abdomen displacement sensor for an automobile crash-test dummy. The test results indicate a positional accuracy of approximately 1 mm rms during 20 m/s motions. The dynamic test results also confirmed earlier covariance model predictions, which were used to optimize the sensor geometry. A covariance analysis was performed to evaluate the applicability of this magnetic position system for tracking a pilot's head motion inside an aircraft cockpit. Realistic design parameters indicate that a robust tracking system, consisting of lightweight pickup coils mounted on a pilot's helmet, and an array of transmitter coils distributed throughout a cockpit, is feasible. Recent test and covariance results are presented.

  12. Electrofracturing test system and method of determining material characteristics of electrofractured material samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauer, Stephen J.; Glover, Steven F.; Pfeifle, Tom

    A device for electrofracturing a material sample and analyzing the material sample is disclosed. The device simulates an in situ electrofracturing environment so as to obtain electrofractured material characteristics representative of field applications while allowing permeability testing of the fractured sample under in situ conditions.

  13. Factor Structure of the Revised TOEIC[R] Test: A Multiple-Sample Analysis

    ERIC Educational Resources Information Center

    In'nami, Yo; Koizumi, Rie

    2012-01-01

    This study examined the factor structure of the listening and reading sections of the revised Test of English for International Communication (TOEIC[R]) test. The data from the TOEIC IP (institutional program) test taken by 569 English learners were randomly split into two samples (n = 285 vs. 284). Four models (higher-order, correlated,…

  14. A stepwise, 'test-all-positives' methodology to assess gluten-kernel contamination at the serving-size level in gluten-free (GF) oat production.

    PubMed

    Chen, Yumin; Fritz, Ronald D; Kock, Lindsay; Garg, Dinesh; Davis, R Mark; Kasturi, Prabhakar

    2018-02-01

    A step-wise, 'test-all-positive-gluten' analytical methodology has been developed and verified to assess kernel-based gluten contamination (i.e., wheat, barley and rye kernels) during gluten-free (GF) oat production. It targets GF claim compliance at the serving-size level (of a pouch or approximately 40-50g). Oat groats are collected from GF oat production following a robust attribute-based sampling plan then split into 75-g subsamples, and ground. R-Biopharm R5 sandwich ELISA R7001 is used for analysis of all the first15-g portions of the ground sample. A >20-ppm result disqualifies the production lot, while a >5 to <20-ppm result triggers complete analysis of the remaining 60-g of ground sample, analyzed in 15-g portions. If all five 15-g test results are <20ppm, and their average is <10.67ppm (since a 20-ppm contaminant in 40g of oats would dilute to 10.67ppm in 75-g), the lot is passed. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Impact of Different Visual Field Testing Paradigms on Sample Size Requirements for Glaucoma Clinical Trials.

    PubMed

    Wu, Zhichao; Medeiros, Felipe A

    2018-03-20

    Visual field testing is an important endpoint in glaucoma clinical trials, and the testing paradigm used can have a significant impact on the sample size requirements. To investigate this, this study included 353 eyes of 247 glaucoma patients seen over a 3-year period to extract real-world visual field rates of change and variability estimates to provide sample size estimates from computer simulations. The clinical trial scenario assumed that a new treatment was added to one of two groups that were both under routine clinical care, with various treatment effects examined. Three different visual field testing paradigms were evaluated: a) evenly spaced testing, b) United Kingdom Glaucoma Treatment Study (UKGTS) follow-up scheme, which adds clustered tests at the beginning and end of follow-up in addition to evenly spaced testing, and c) clustered testing paradigm, with clusters of tests at the beginning and end of the trial period and two intermediary visits. The sample size requirements were reduced by 17-19% and 39-40% using the UKGTS and clustered testing paradigms, respectively, when compared to the evenly spaced approach. These findings highlight how the clustered testing paradigm can substantially reduce sample size requirements and improve the feasibility of future glaucoma clinical trials.

  16. A Psychometric Analysis of the Positive and Negative Affect Schedule for Children-Parent Version in a School Sample

    ERIC Educational Resources Information Center

    Ebesutani, Chad; Okamura, Kelsie; Higa-McMillan, Charmaine; Chorpita, Bruce F.

    2011-01-01

    The current study was the 1st to examine the psychometric properties of the Positive and Negative Affect Schedule for Children-Parent Version (PANAS-C-P) using a large school-based sample of children and adolescents ages 8 to 18 (N = 606). Confirmatory factor analysis supported a 2-factor (correlated) model of positive affect (PA) and negative…

  17. Advances in paper-based sample pretreatment for point-of-care testing.

    PubMed

    Tang, Rui Hua; Yang, Hui; Choi, Jane Ru; Gong, Yan; Feng, Shang Sheng; Pingguan-Murphy, Belinda; Huang, Qing Sheng; Shi, Jun Ling; Mei, Qi Bing; Xu, Feng

    2017-06-01

    In recent years, paper-based point-of-care testing (POCT) has been widely used in medical diagnostics, food safety and environmental monitoring. However, a high-cost, time-consuming and equipment-dependent sample pretreatment technique is generally required for raw sample processing, which are impractical for low-resource and disease-endemic areas. Therefore, there is an escalating demand for a cost-effective, simple and portable pretreatment technique, to be coupled with the commonly used paper-based assay (e.g. lateral flow assay) in POCT. In this review, we focus on the importance of using paper as a platform for sample pretreatment. We firstly discuss the beneficial use of paper for sample pretreatment, including sample collection and storage, separation, extraction, and concentration. We highlight the working principle and fabrication of each sample pretreatment device, the existing challenges and the future perspectives for developing paper-based sample pretreatment technique.

  18. Use of Dried Capillary Blood Sampling for Islet Autoantibody Screening in Relatives: A Feasibility Study.

    PubMed

    Bingley, Polly J; Rafkin, Lisa E; Matheson, Della; Steck, Andrea K; Yu, Liping; Henderson, Courtney; Beam, Craig A; Boulware, David C

    2015-12-01

    Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot-based screening to identify islet autoantibody-positive relatives potentially eligible for inclusion in prevention trials. Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies.

  19. Use of Dried Capillary Blood Sampling for Islet Autoantibody Screening in Relatives: A Feasibility Study

    PubMed Central

    Rafkin, Lisa E.; Matheson, Della; Steck, Andrea K.; Yu, Liping; Henderson, Courtney; Beam, Craig A.; Boulware, David C.

    2015-01-01

    Abstract Background: Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot–based screening to identify islet autoantibody–positive relatives potentially eligible for inclusion in prevention trials. Materials and Methods: Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Results: Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Conclusions: Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies. PMID:26375197

  20. Detection of sorbitol-negative and sorbitol-positive Shiga toxin-producing Escherichia coli, Listeria monocytogenes, Campylobacter jejuni, and Salmonella spp. in dairy farm environmental samples.

    PubMed

    Murinda, S E; Nguyen, L T; Nam, H M; Almeida, R A; Headrick, S J; Oliver, S P

    2004-01-01

    Six visits were conducted to four dairy farms to collect swab, liquid, and solid dairy farm environmental samples (165 to 180/farm; 15 sample types). The objective of the study was to determine on-farm sources of Campylobacter jejuni, Salmonella spp., Listeria monocytogenes, and Shiga toxin-producing Escherichia coli (STEC), which might serve as reservoirs for transmission of pathogens. Samples were analyzed using mostly U.S. Food and Drug Administration's Bacteriological Analytical Manual protocols; however, Salmonella spp., L. monocytogenes and STEC were co-enriched in universal pre-enrichment broth. Campylobacter jejuni were enriched in Bolton broth containing Bolton broth supplement. Pathogens were isolated on agar media, typed biochemically, and confirmed using multiplex polymerase chain reaction protocols. Campylobacter jejuni, Salmonella spp., L. monocytogenes, Sorbitol-negative (SN)-STEC O157:H7, and sorbitol-positive (SP)-STEC, respectively, were isolated from 5.06%, 3.76%, 6.51%, 0.72%, and 17.3% of samples evaluated. Whereas other pathogens were isolated from all four farms, SN-STEC O157:H7 were isolated from only two farms. Diverse serotypes of SP-STEC including O157:H7, O26:H11, O111, and O103 were isolated. None of the five pathogen groups studied were isolated from bulk tank milk (BTM). Most pathogens (44.2%) were isolated directly from fecal samples. Bovine fecal samples, lagoon water, bedding, bird droppings, and rat intestinal contents constituted areas of major concern on dairy farms. Although in-line milk filters from two farms tested positive for Salmonella or L. monocytogenes, none of the pathogens were detected in the corresponding BTM samples. Good manure management practices, including control of feral animals, are critical in assuring dairy farm hygiene. Identification of on-farm pathogen reservoirs could aid with implementation of farm-specific pathogen reduction programs.

  1. CTBTO Contractor Laboratory Test Sample Production Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bob Hague; Tracy Houghton; Nick Mann

    2013-08-01

    In October 2012 scientists from both Idaho National Laboratory (INL) and the CTBTO contact laboratory at Seibersdorf, Austria designed a system and capability test to determine if the INL could produce and deliver a short lived radio xenon standard in time for the standard to be measured at the CTBTO contact laboratory at Seibersdorf, Austria. The test included sample standard transportation duration and potential country entrance delays at customs. On October 23, 2012 scientists at the Idaho National Laboratory (INL) prepared and shipped a Seibersdorf contract laboratory supplied cylinder. The canister contained 1.0 scc of gas that consisted of 70%more » xenon and 30% nitrogen by volume. The t0 was October 24, 2012, 1200 ZULU. The xenon content was 0.70 +/ 0.01 scc at 0 degrees C. The 133mXe content was 4200 +/ 155 dpm per scc of stable xenon on t0 (1 sigma uncertainty). The 133Xe content was 19000 +/ 800 dpm per scc of stable xenon on t0 (1 sigma uncertainty).« less

  2. Responses to crizotinib in patients with ALK-positive lung adenocarcinoma who tested immunohistochemistry (IHC)-positive and fluorescence in situ hybridization (FISH)-negative.

    PubMed

    Ma, Di; Wang, Zheng; Yang, Lin; Mu, Xinlin; Wang, Yan; Zhao, Xinming; Li, Junling; Lin, Dongmei

    2016-09-27

    Although the Ventana immunohistochemistry (IHC) platform for detecting anaplastic lymphoma kinase gene (ALK) (D5F3) expression was recently approved by the US Food and Drugs Administration (FDA), fluorescence in situ hybridization (FISH) is still the "gold-standard" method recommended by the US National Comprehensive Cancer Network (NCCN) guideline for NSCLC. We evaluated 6 ALK-positive lung adenocarcinoma patients who tested Ventana IHC-positive and FISH-negative and assessed their clinical responses to the ALK tyrosine kinase inhibitor (TKI) crizotinib. Histologic and cytologic specimens from the 6 patients were stained with Ventana anti-ALK(D5F3) rabbit monoclonal primary antibody using the OptiView™ DAB IHC detection kit and OptiView™ amplification kit on a Ventana BenchMark XT processor. In addition, they were also tested by FISH, qRT-PCR, next-generation sequencing (NGS), and RNAscope ISH analysis. All patients received crizotinib treatment and their follow-up clinical data were recorded. The objective response rate achieved with crizotinib therapy was 66.7% (4/6 partial responses and 2/6 stable disease). One patient in whom a new fusion type (EML4->EXOC6B->ALK fusion) was identified obtained a partial response. These findings indicate that patients with ALK-positive lung adenocarcinoma who test Ventana IHC-positive and FISH-negative may still respond to crizotinib therapy.

  3. Clinical evaluation of Roche COBAS® AmpliPrep/COBAS® TaqMan® CMV Test using non-plasma samples.

    PubMed

    Hildenbrand, Cynthia; Wedekind, Laura; Li, Ge; vonRentzell, Jeanne E; Shah, Krunal; Rooney, Paul; Harrington, Amanda T; Zhao, Richard Y

    2018-05-24

    Cytomegalovirus (CMV) infection is a leading cause of loss of hearing, vision, and mental retardation in congenitally infected children. It is also associated with complications of organ-transplant and opportunistic HIV co-infection. The Roche COBAS ® AmpliPrep/COBAS ® TaqMan ® CMV Test is a FDA-approved test that measures CMV DNA viral load in plasma for the diagnosis and management of patients at risk for CMV-associated diseases. Besides plasma, CMV is often found in bronchoalveolar lavage (BAL), cerebrospinal fluid (CSF) and urine. Thus, monitoring of CMV for critical care of patients in these non-plasma samples becomes necessary. The objective of this study was to conduct an analytic and clinical feasibility study of the Roche CMV Test in BAL, CSF, and urine. The lower limit of detection (LOD), analytic measurement range (AMR), assay sensitivity, specificity, and precision were determined. Results of this study showed the LODs were 50, 100 and 300 IU/mL for BAL, CSF, or urine, respectively. The AMRs were from log 10 2.48 to log 10 5.48. The assay specificity was 94.4% for BAL, and 100% for CSF and urine. The assay precision was all within the acceptable range. The performance of Roche test was further compared with two comparators including the RealTime CMV Assay (Abbott Molecular) and a CMV Quantitative PCR Test (Vela Diagnostics). There was a general positive correlation between the Roche method and the Abbott or the Vela method. Overall, this study suggests the Roche CMV Test is suitable for the quantification of CMV viral load DNA in the described non-plasma samples. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  4. Positive "alveolar" responses to antigen inhalation provocation tests: their validity and recognition.

    PubMed Central

    Hendrick, D J; Marshall, R; Faux, J A; Krall, J M

    1980-01-01

    The validity of inhalation tests in the investigation of extrinsic allergic alveolitis was assessed from the results of 144 antigen and control tests in 31 subjects. A definitive pattern of positive late responses was observed. Reactions to nebulised bird serum and droppings in subjects with bird fancier's lung were identical to reactions after "natural" exposures in aviaries or lofts, and to reactions after "occupational" challenges in subjects with farmer's lung and mushroom worker's lung. In general, positive tests were easily recognised subjectively from symptoms and signs appropriate to an influenza-like illness and undue respiratory effort on exercise. They were associated with significant changes in six readily available objective monitoring measurements--exercise minute ventilation (greater than or equal to +15%), body temperature (> 37.2 degrees C), circulating neutrophils (greater than or equal to +2500/mm3), exercise respiratory frequency (greater than or equal to +25%), circulating lymphocytes (greater than ore equal to -500/mm3 with lymphopenia), and forced vital capacity (greater than or equal to -15%). These confirmatory monitoring tests had specificities of approximately 95% and sensitivities of 85-48%. Measurement of diffusing capacity, lung volume subdivisions, or resting minute ventilation/respiratory frequency proved to be too insensitive to be useful, as did auscultation and chest radiography. We conclude that responses that do provoke significant changes in these less sensitive tests are unnecessarily distressing and, presumable, unnecessarily hazardous. PMID:7434297

  5. A Peer Counselling Program for Persons Testing H.I.V. Antibody Positive.

    ERIC Educational Resources Information Center

    Baiss, Alan

    1989-01-01

    Describes need for and development of a peer counseling program for persons who have tested positive for human immunodeficiency virus (HIV) antibodies. Discusses selection of peer counselors, training, and confidentiality. Includes discussion of future plans. (ABL)

  6. Rapid Strep Test

    MedlinePlus

    ... the sample to an outside lab for additional testing. It could take up to two days to get the results. If the test is positive for the strep infection, your doctor will prescribe an antibiotic to kill the bacteria. Things to consider Strep ...

  7. [A short form of the positions on nursing diagnosis scale: development and psychometric testing].

    PubMed

    Romero-Sánchez, José Manuel; Paloma-Castro, Olga; Paramio-Cuevas, Juan Carlos; Pastor-Montero, Sonia María; O'Ferrall-González, Cristina; Gabaldón-Bravo, Eva Maria; González-Domínguez, Maria Eugenia; Castro-Yuste, Cristina; Frandsen, Anna J; Martínez-Sabater, Antonio

    2013-06-01

    The Positions on Nursing Diagnosis (PND) is a scale that uses the semantic differential technique to measure nurses' attitudes towards the nursing diagnosis concept. The aim of this study was to develop a shortened form of the Spanish version of this scale and evaluate its psychometric properties and efficiency. A double theoretical-empirical approach was used to obtain a short form of the PND, the PND-7-SV, which would be equivalent to the original. Using a cross-sectional survey design, the reliability (internal consistency and test-retest reliability), construct (exploratory factor analysis, known-groups technique and discriminant validity) and criterion-related validity (concurrent validity), sensitivity to change and efficiency of the PND-7-SV were assessed in a sample of 476 Spanish nursing students. The results endorsed the utility of the PND-7-SV to measure attitudes toward nursing diagnosis in an equivalent manner to the complete form of the scale and in a shorter time.

  8. Test Performance and Test-Retest Reliability of the Vestibular/Ocular Motor Screening and King-Devick Test in Adolescent Athletes During a Competitive Sport Season.

    PubMed

    Worts, Phillip R; Schatz, Philip; Burkhart, Scott O

    2018-05-01

    The Vestibular/Ocular Motor Screening (VOMS) and King-Devick (K-D) test are tools designed to assess ocular or vestibular function after a sport-related concussion. To determine the test-retest reliability and rate of false-positive results of the VOMS and K-D test in a healthy athlete sample. Cohort study (diagnosis); Level of evidence, 2. Forty-five healthy high school student-athletes (mean age, 16.11 ± 1.43 years) completed self-reported demographics and medical history and were administered the VOMS and K-D test during rest on day 1 (baseline). The VOMS and K-D test were administered again once during rest (prepractice) and once within 5 minutes of removal from sport practice on day 2 (removal). The Borg rating of perceived exertion scale was administered at removal. Intraclass correlation coefficients were used to determine test-retest reliability on the K-D test and the average near point of convergence (NPC) distance on the VOMS. Level of agreement was used to examine VOMS symptom provocation over the 3 administration times. Multivariate base rates were used to determine the rate of false-positive results when simultaneously considering multiple clinical cutoffs. Test-retest reliability of total time on the K-D test (0.91 [95% CI, 0.86-0.95]) and NPC distance (0.91 [95% CI, 0.85-0.95]) was high across the 3 administration times. Level of agreement ranged from 48.9% to 88.9% across all 3 times for the VOMS items. Using established clinical cutoffs, false-positive results occurred in 2% of the sample using the VOMS at removal and 36% using the K-D test. The VOMS displayed a false-positive rate of 2% in this high school student-athlete cohort. The K-D test's false-positive rate was 36% while maintaining a high level of test-retest reliability (0.91). Results from this study support future investigation of VOMS administration in an acutely injured high school athletic sample. Going forward, the VOMS may be more stable than other neurological and symptom report

  9. It's Time to Develop a New "Draft Test Protocol" for a Mars Sample Return Mission (or Two…).

    PubMed

    Rummel, John D; Kminek, Gerhard

    2018-04-01

    The last time NASA envisioned a sample return mission from Mars, the development of a protocol to support the analysis of the samples in a containment facility resulted in a "Draft Test Protocol" that outlined required preparations "for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth" (Rummel et al., 2002 ). This document comprised a specific protocol to be used to conduct a biohazard test for a returned martian sample, following the recommendations of the Space Studies Board of the US National Academy of Sciences. Given the planned launch of a sample-collecting and sample-caching rover (Mars 2020) in 2 years' time, and with a sample return planned for the end of the next decade, it is time to revisit the Draft Test Protocol to develop a sample analysis and biohazard test plan to meet the needs of these future missions. Key Words: Biohazard detection-Mars sample analysis-Sample receiving facility-Protocol-New analytical techniques-Robotic sample handling. Astrobiology 18, 377-380.

  10. Vacuum compatible sample positioning device for matrix assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aizikov, Konstantin; Lin, Tzu-Yung; Department of Electrical and Computer Engineering, Boston University, Boston, Massachusetts 02215

    The high mass accuracy and resolving power of Fourier transform ion cyclotron resonance mass spectrometers (FT-ICR MS) make them ideal mass detectors for mass spectrometry imaging (MSI), promising to provide unmatched molecular resolution capabilities. The intrinsic low tolerance of FT-ICR MS to RF interference, however, along with typically vertical positioning of the sample, and MSI acquisition speed requirements present numerous engineering challenges in creating robotics capable of achieving the spatial resolution to match. This work discusses a two-dimensional positioning stage designed to address these issues. The stage is capable of operating in {approx}1 x 10{sup -8} mbar vacuum. The rangemore » of motion is set to 100 mm x 100 mm to accommodate large samples, while the positioning accuracy is demonstrated to be less than 0.4 micron in both directions under vertical load over the entire range. This device was integrated into three different matrix assisted laser desorption/ionization (MALDI) FT-ICR instruments and showed no detectable RF noise. The ''oversampling'' MALDI-MSI experiments, under which the sample is completely ablated at each position, followed by the target movement of the distance smaller than the laser beam, conducted on the custom-built 7T FT-ICR MS demonstrate the stability and positional accuracy of the stage robotics which delivers high spatial resolution mass spectral images at a fraction of the laser spot diameter.« less

  11. Evaluation of sampling methods for measuring exposure to volatile inorganic acids in workplace air. Part 1: sampling hydrochloric acid (HCl) and nitric acid (HNO₃) from a test gas atmosphere.

    PubMed

    Howe, Alan; Musgrove, Darren; Breuer, Dietmar; Gusbeth, Krista; Moritz, Andreas; Demange, Martine; Oury, Véronique; Rousset, Davy; Dorotte, Michel

    2011-08-01

    Historically, workplace exposure to the volatile inorganic acids hydrochloric acid (HCl) and nitric acid (HNO(3)) has been determined mostly by collection on silica gel sorbent tubes and analysis of the corresponding anions by ion chromatography (IC). However, HCl and HNO(3) can be present in workplace air in the form of mist as well as vapor, so it is important to sample the inhalable fraction of airborne particles. As sorbent tubes exhibit a low sampling efficiency for inhalable particles, a more suitable method was required. This is the first of two articles on "Evaluation of Sampling Methods for Measuring Exposure to Volatile Inorganic Acids in Workplace Air" and describes collaborative sampling exercises carried out to evaluate an alternative method for sampling HCl and HNO(3) using sodium carbonate-impregnated filters. The second article describes sampling capacity and breakthrough tests. The method was found to perform well and a quartz fiber filter impregnated with 500 μL of 1 M Na(2)CO(3) (10% (m/v) Na(2)CO(3)) was found to have sufficient sampling capacity for use in workplace air measurement. A pre-filter is required to remove particulate chlorides and nitrates that when present would otherwise result in a positive interference. A GSP sampler fitted with a plastic cone, a closed face cassette, or a plastic IOM sampler were all found to be suitable for mounting the pre-filter and sampling filter(s), but care has to be taken with the IOM sampler to ensure that the sampler is tightly closed to avoid leaks. HCl and HNO(3) can react with co-sampled particulate matter on the pre-filter, e.g., zinc oxide, leading to low results, and stronger acids can react with particulate chlorides and nitrates removed by the pre-filter to liberate HCl and HNO(3), which are subsequently collected on the sampling filter, leading to high results. However, although there is this potential for both positive and negative interferences in the measurement, these are unavoidable

  12. Sensitivity or artifact? -- IQ Toxicity Test -- effluent values

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hayes, K.R.; Novotny, A.N.; Batista, N.

    1995-12-31

    Several complex effluents were DAPHNIA MAGNA IQ TOXICITY TESTED -- (1.25 hours) and conventionally tested with Daphnia magna (48 hours). In many samples the IQ Technology yielded low EC50 values while the 48 hour exposures yielded no acute toxicity. Possible explanations have been suggested for this occurrence such as: genotoxicity, mutagenicity, substrate interference, and enzyme satiation. To identify the causative agent(s) of this response a Toxicity Identification Evaluation was performed on one of the samples. To define the nature of the response, THE SOS-CHROMOTEST KIT and THE MUTA-CHROMOPLATE KIT were utilized to characterize genotoxicity and mutagenicity respectively. The sample didmore » not test positive for genotoxicity but tested positive for mutagenicity only after activation with S9 enzymes, suggesting the presence of promutagens. Additional work needs to be performed to correlate IQ TOXICITY TEST sensitivity with positive MUTA-CHROMOPLATE response.« less

  13. Development of a superconducting position sensor for the Satellite Test of the Equivalence Principle

    NASA Astrophysics Data System (ADS)

    Clavier, Odile Helene

    The Satellite Test of the Equivalence Principle (STEP) is a joint NASA/ESA mission that proposes to measure the differential acceleration of two cylindrical test masses orbiting the earth in a drag-free satellite to a precision of 10-18 g. Such an experiment would conceptually reproduce Galileo's tower of Pisa experiment with a much longer time of fall and greatly reduced disturbances. The superconducting test masses are constrained in all degrees of freedom except their axial direction (the sensitive axis) using superconducting bearings. The STEP accelerometer measures the differential position of the masses in their sensitive direction using superconducting inductive pickup coils coupled to an extremely sensitive magnetometer called a DC-SQUID (Superconducting Quantum Interference Device). Position sensor development involves the design, manufacture and calibration of pickup coils that will meet the acceleration sensitivity requirement. Acceleration sensitivity depends on both the displacement sensitivity and stiffness of the position sensor. The stiffness must kept small while maintaining stability of the accelerometer. Using a model for the inductance of the pickup coils versus displacement of the test masses, a computer simulation calculates the sensitivity and stiffness of the accelerometer in its axial direction. This simulation produced a design of pickup coils for the four STEP accelerometers. Manufacture of the pickup coils involves standard photolithography techniques modified for superconducting thin-films. A single-turn pickup coil was manufactured and produced a successful superconducting coil using thin-film Niobium. A low-temperature apparatus was developed with a precision position sensor to measure the displacement of a superconducting plate (acting as a mock test mass) facing the coil. The position sensor was designed to detect five degrees of freedom so that coupling could be taken into account when measuring the translation of the plate

  14. Testing comprehensive models of disclosure of sexual orientation in HIV-positive Latino men who have sex with men (MSM).

    PubMed

    García, Luis I; Lechuga, Julia; Zea, María Cecilia

    2012-01-01

    Individuals who disclose their sexual orientation are more likely to also disclose their HIV status. Disclosure of HIV-serostatus is associated with better health outcomes. The goal of this study was to build and test comprehensive models of sexual orientation that included eight theory-informed predictors of disclosure to mothers, fathers, and closest friends in a sample of HIV-positive Latino gay and bisexual men. US acculturation, gender nonconformity to hegemonic masculinity in self-presentation, comfort with sexual orientation, gay community involvement, satisfaction with social support, sexual orientation and gender of the closest friend emerged as significant predictors of disclosure of sexual orientation.

  15. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.

    PubMed

    Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz

    The aim of this study was to evaluate the QuickVue ® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue ® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue ® RSV Test and viral load or specific strain. The QuickVue ® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue ® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  16. A HUPO test sample study reveals common problems in mass spectrometry-based proteomics

    PubMed Central

    Bell, Alexander W.; Deutsch, Eric W.; Au, Catherine E.; Kearney, Robert E.; Beavis, Ron; Sechi, Salvatore; Nilsson, Tommy; Bergeron, John J.M.

    2009-01-01

    We carried out a test sample study to try to identify errors leading to irreproducibility, including incompleteness of peptide sampling, in LC-MS-based proteomics. We distributed a test sample consisting of an equimolar mix of 20 highly purified recombinant human proteins, to 27 laboratories for identification. Each protein contained one or more unique tryptic peptides of 1250 Da to also test for ion selection and sampling in the mass spectrometer. Of the 27 labs, initially only 7 labs reported all 20 proteins correctly, and only 1 lab reported all the tryptic peptides of 1250 Da. Nevertheless, a subsequent centralized analysis of the raw data revealed that all 20 proteins and most of the 1250 Da peptides had in fact been detected by all 27 labs. The centralized analysis allowed us to determine sources of problems encountered in the study, which include missed identifications (false negatives), environmental contamination, database matching, and curation of protein identifications. Improved search engines and databases are likely to increase the fidelity of mass spectrometry-based proteomics. PMID:19448641

  17. Western blotting method (TESAcruzi) as a supplemental test for confirming the presence of anti-Trypanosoma cruzi antibodies in finger prick blood samples from children aged 0-5 years in Brazil.

    PubMed

    Frade, Amanda Farage; Luquetti, Alejandro O; Prata, Aluísio; Ferreira, Antonio Walter

    2011-01-01

    Some Latin American countries have plans for total control and/or eradication of Chagas disease by the main vector (Triatoma infestans) and by blood transfusion. To achieve this, patients with Chagas disease must be identified. A Western blotting test, TESAcruzi, is described as a supplemental test for diagnosis of Chagas disease using samples collected from children <5 years living in different states of Brazil. Blood samples collected by finger prick on filter paper were sent to the test laboratory by a central laboratory to confirm results obtained previously. Ten percent of negative samples, all doubtful and all positive samples were received. Commercial reagents, IgG indirect immunofluorescence, enzyme immunoassay, and a recently introduced TESAcruzi test were used. From 8788 samples, 163 (1.85%) were reactive by IgG-ELISA and 312 (3.55%) by IgG IIF. From these, 77 (0.87%) were reactive in the TESAcruzi test. The results had high clinical value to identify those truly infected. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. Usefulness of Sofia Pneumococcal FIA® test in comparison with BinaxNOW® Pneumococcal test in urine samples for the diagnosis of pneumococcal pneumonia.

    PubMed

    Burgos, Joaquin; Garcia-Pérez, Jorge N; di Lauro, Sabina González; Falcó, Vicenç; Pumarola, Tomás; Almirante, Benito; Teresa Martín Gomez, M

    2018-04-13

    The Sofia Pneumococcal FIA® test is a recently introduced immunofluorescent assay automatically read aimed to detect Streptococcus pneumoniae antigen in urine. The aim of this study was to evaluate the usefulness of SofiaFIA® urinary antigen test (UAT) in comparison with classical immunochromatographic BinaxNOW® test for the diagnosis of pneumococcal pneumonia (PP). Observational study was conducted in the Hospital Universitari Vall d'Hebron from December 2015 to August 2016. Consecutive adult patients diagnosed of pneumonia and admitted to the emergency department in whom UAT was requested were prospectively enrolled. Paired pneumococcal UAT was performed (BinaxNOW® and SofiaFIA®) in urine samples. To assess the performance of both tests, patients were categorized into proven PP (isolation of S. pneumoniae in sterile fluid) or probable PP (isolation of S. pneumoniae in respiratory secretion). Sensitivity, specificity, and concordance were calculated. A total of 219 patients with pneumonia were enrolled, of whom 14% had a proven or probable PP, 22% a non-pneumococcal etiology, and 64% an unidentified pathogen. Concordance between tests was good (κ = 0.81). Sensitivity of SofiaFIA® and BinaxNOW® UAT was 78.6 and 50% for proven PP (p = 0.124), and 74.2 and 58% for proven/probable PP (p = 0.063). Specificity for both tests was 83.3 and 85.5% for proven and proven/probable PP. In patients without an identified pathogen, SofiaFIA® test was positive in 33 (23.6%) cases and BinaxNOW® in 25 (17.8%), so Sofia Pneumococcal FIA® detected 32.6% more cases than BinaxNOW® (p = 0.001). Sofia Pneumococcal FIA® test showed an improved sensitivity over visual reading of BinaxNOW® test without a noticeable loss of specificity.

  19. Positive affect and psychosocial processes related to health.

    PubMed

    Steptoe, Andrew; O'Donnell, Katie; Marmot, Michael; Wardle, Jane

    2008-05-01

    Positive affect is associated with longevity and favourable physiological function. We tested the hypothesis that positive affect is related to health-protective psychosocial characteristics independently of negative affect and socio-economic status. Both positive and negative affect were measured by aggregating momentary samples collected repeatedly over 1 day, and health-related psychosocial factors were assessed by questionnaire in a sample of 716 men and women aged 58-72 years. Positive affect was associated with greater social connectedness, emotional and practical support, optimism and adaptive coping responses, and lower depression, independently of age, gender, household income, paid employment, smoking status, and negative affect. Negative affect was independently associated with negative relationships, greater exposure to chronic stress, depressed mood, pessimism, and avoidant coping. Positive affect may be beneficial for health outcomes in part because it is a component of a profile of protective psychosocial characteristics.

  20. Results from tests of TFL Hydragard sampling loop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steimke, J.L.

    When the Defense Waste Processing Facility (DWPF) is operational, processed radioactive sludge will be transferred in batches to the Slurry Mix Evaporator (SME), where glass frit will be added and the contents concentrated by boiling. Batches of the slurry mixture are transferred from the SME to the Melter Feed Tank (MFT). Hydragard{reg_sign} sampling systems are used on the SME and the MFT for collecting slurry samples in vials for chemical analysis. An accurate replica of the Hydragard sampling system was built and tested in the thermal Fluids Laboratory (TFL) to determine the hydragard accuracy. It was determined that the originalmore » Hydragard valve frequently drew a non-representative sample stream through the sample vial that ranged from frit enriched to frit depleted. The Hydragard valve was modified by moving the plunger and its seat backwards so that the outer surface of the plunger was flush with the inside diameter of the transfer line when the valve was open. The slurry flowing through the vial accurately represented the composition of the slurry in the reservoir for two types of slurries, different dilution factors, a range of transfer flows and a range of vial flows. It was then found that the 15 ml of slurry left in the vial when the Hydragard valve was closed, which is what will be analyzed at DWPF, had a lower ratio of frit to sludge as characterized by the lithium to iron ratio than the slurry flowing through it. The reason for these differences is not understood at this time but it is recommended that additional experimentation be performed with the TFL Hydragard loop to determine the cause.« less