Sample records for sampling kit biskit

  1. Evaluation of the Biological Sampling Kit (BiSKit) for Large-Area Surface Sampling

    PubMed Central

    Buttner, Mark P.; Cruz, Patricia; Stetzenbach, Linda D.; Klima-Comba, Amy K.; Stevens, Vanessa L.; Emanuel, Peter A.

    2004-01-01

    Current surface sampling methods for microbial contaminants are designed to sample small areas and utilize culture analysis. The total number of microbes recovered is low because a small area is sampled, making detection of a potential pathogen more difficult. Furthermore, sampling of small areas requires a greater number of samples to be collected, which delays the reporting of results, taxes laboratory resources and staffing, and increases analysis costs. A new biological surface sampling method, the Biological Sampling Kit (BiSKit), designed to sample large areas and to be compatible with testing with a variety of technologies, including PCR and immunoassay, was evaluated and compared to other surface sampling strategies. In experimental room trials, wood laminate and metal surfaces were contaminated by aerosolization of Bacillus atrophaeus spores, a simulant for Bacillus anthracis, into the room, followed by settling of the spores onto the test surfaces. The surfaces were sampled with the BiSKit, a cotton-based swab, and a foam-based swab. Samples were analyzed by culturing, quantitative PCR, and immunological assays. The results showed that the large surface area (1 m2) sampled with the BiSKit resulted in concentrations of B. atrophaeus in samples that were up to 10-fold higher than the concentrations obtained with the other methods tested. A comparison of wet and dry sampling with the BiSKit indicated that dry sampling was more efficient (efficiency, 18.4%) than wet sampling (efficiency, 11.3%). The sensitivities of detection of B. atrophaeus on metal surfaces were 42 ± 5.8 CFU/m2 for wet sampling and 100.5 ± 10.2 CFU/m2 for dry sampling. These results demonstrate that the use of a sampling device capable of sampling larger areas results in higher sensitivity than that obtained with currently available methods and has the advantage of sampling larger areas, thus requiring collection of fewer samples per site. PMID:15574898

  2. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  3. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  4. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  5. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  6. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  7. Comparison of three DNA extraction kits to establish maximum yield and quality of coral-associated microbial DNA

    USGS Publications Warehouse

    Baker, Erin J.; Kellogg, Christina A.

    2014-01-01

    Coral microbiology is an expanding field, yet there is no standard DNA extraction protocol. Although many researchers depend on commercial extraction kits, no specific kit has been optimized for use with coral samples. Both soil and plant DNA extraction kits from MO BIO Laboratories, Inc., have been used by many research groups for this purpose. MO BIO recently replaced their PowerPlant® kit with an improved PowerPlantPro kit, but it was unclear how these changes would affect the kit’s use with coral samples. In order to determine which kit produced the best results, we conducted a comparison between the original PowerPlant kit, the new PowerPlantPro kit, and an alternative kit, PowerSoil, using samples from several different coral genera. The PowerPlantPro kit had the highest DNA yields, but the lack of 16S rRNA gene amplification in many samples suggests that much of the yield may be coral DNA rather than microbial DNA. The most consistent positive amplifications came from the PowerSoil kit.

  8. Evaluation of four commercial quantitative real-time PCR kits with inhibited and degraded samples.

    PubMed

    Holmes, Amy S; Houston, Rachel; Elwick, Kyleen; Gangitano, David; Hughes-Stamm, Sheree

    2018-05-01

    DNA quantification is a vital step in forensic DNA analysis to determine the optimal input amount for DNA typing. A quantitative real-time polymerase chain reaction (qPCR) assay that can predict DNA degradation or inhibitors present in the sample prior to DNA amplification could aid forensic laboratories in creating a more streamlined and efficient workflow. This study compares the results from four commercial qPCR kits: (1) Investigator® Quantiplex® Pro Kit, (2) Quantifiler® Trio DNA Quantification Kit, (3) PowerQuant® System, and (4) InnoQuant® HY with high molecular weight DNA, low template samples, degraded samples, and DNA spiked with various inhibitors.The results of this study indicate that all kits were comparable in accurately predicting quantities of high quality DNA down to the sub-picogram level. However, the InnoQuant(R) HY kit showed the highest precision across the DNA concentration range tested in this study. In addition, all kits performed similarly with low concentrations of forensically relevant PCR inhibitors. However, in general, the Investigator® Quantiplex® Pro Kit was the most tolerant kit to inhibitors and provided the most accurate quantification results with higher concentrations of inhibitors (except with salt). PowerQuant® and InnoQuant® HY were the most sensitive to inhibitors, but they did indicate significant levels of PCR inhibition. When quantifying degraded samples, each kit provided different degradation indices (DI), with Investigator® Quantiplex® Pro indicating the largest DI and Quantifiler® Trio indicating the smallest DI. When the qPCR kits were paired with their respective STR kit to genotype highly degraded samples, the Investigator® 24plex QS and GlobalFiler® kits generated more complete profiles when the small target concentrations were used for calculating input amount.

  9. Investigation of c-KIT and Ki67 expression in normal, preneoplastic and neoplastic canine prostate.

    PubMed

    Fonseca-Alves, Carlos Eduardo; Kobayashi, Priscilla Emiko; Palmieri, Chiara; Laufer-Amorim, Renée

    2017-12-06

    c-KIT expression has been related to bone metastasis in human prostate cancer, but whether c-KIT expression can be similarly classified in canine prostatic tissue is unknown. This study assessed c-KIT and Ki67 expression in canine prostate cancer (PC). c-KIT gene and protein expression and Ki67 expression were evaluated in forty-four canine prostatic tissues by immunohistochemistry, RT-qPCR and western blot. Additionally, we have investigated c-KIT protein expression by immunoblotting in two primary canine prostate cancer cell lines. Eleven normal prostates, 12 proliferative inflammatory atrophy (PIA) prostates, 18 PC, 3 metastatic lesions and two prostate cancer cell cultures (PC1 and PC2) were analysed. The prostatic tissue exhibited varying degrees of membranous, cytoplasmic or membranous/cytoplasmic c-KIT staining. Four normal prostates, 4 PIA and 5 prostatic carcinomas showed positive c-KIT expression. No c-KIT immunoexpression was observed in metastases. Canine prostate cancer and PIA samples contained a higher number of Ki67-positive cells compared to normal samples. The median relative quantification (RQ) for c-KIT expression in normal, PIA and prostate cancer and metastatic samples were 0.6 (0.1-2.5), 0.7 (0.09-2.1), 0.7 (0.09-5.1) and 0.1 (0.07-0.6), respectively. A positive correlation between the number of Ki67-positive cells and c-KIT transcript levels was observed in prostate cancer samples. In the cell line, PC1 was negative for c-KIT protein expression, while PC2 was weakly positive. The present study identified a strong correlation between c-KIT expression and proliferative index, suggesting that c-KIT may influence cell proliferation. Therefore, c-KIT heterogeneous protein expression among the samples (five positive and thirteen negative prostate cancer samples) indicates a personalized approach for canine prostate cancer.

  10. [Comparison and evaluation of the Binax EIA and Biotest EIA urinary antigen kits for detection of Legionella pneumophila antigen in urine samples].

    PubMed

    Rastawicki, Waldemar; Rokosz, Natalia; Jagielski, Marek

    2011-01-01

    The Binax and the Biotest urinary antigen kits for detection of L. pneumophila antigen were compared by testing of selected 67 urine samples obtained from EWGLI as reference samples in External Quality Assessment Scheme. Thirty nine were positive with the Binax kit (100% of sensitivity), and 33 were positive with the Biotest (84.6% of sensitivity). The test specificities were 100% for the both kits. It was concluded that the Binax kit was more suitable for the routine diagnosis of Legionella infections than the Biotest kit.

  11. Comparative sensitivity and inhibitor tolerance of GlobalFiler® PCR Amplification and Investigator® 24plex QS kits for challenging samples.

    PubMed

    Elwick, Kyleen; Mayes, Carrie; Hughes-Stamm, Sheree

    2018-05-01

    In cases such as mass disasters or missing persons, human remains are challenging to identify as they may be fragmented, burnt, been buried, decomposed, and/or contain inhibitory substances. This study compares the performance of a relatively new STR kit in the US market (Investigator® 24plex QS kit; Qiagen) with the GlobalFiler® PCR Amplification kit (Thermo Fisher Scientific) when genotyping highly inhibited and low level DNA samples. In this study, DNA samples ranging from 1 ng to 7.8 pg were amplified to define the sensitivity of two systems. In addition, DNA (1 ng and 0.1 ng input amounts) was spiked with various concentrations of five inhibitors common to human remains (humic acid, melanin, hematin, collagen, calcium). Furthermore, bone (N = 5) and tissue samples from decomposed human remains (N = 6) were used as mock casework samples for comparative analysis with both STR kits. The data suggest that the GlobalFiler® kit may be slightly more sensitive than the Investigator® kit. On average STR profiles appeared to be more balanced and average peak heights were higher when using the GlobalFiler® kit. However, the data also show that the Investigator® kit may be more tolerant to common PCR inhibitors. While both STR kits showed a decrease in alleles as the inhibitor concentration increased, more complete profiles were obtained when the Investigator® kit was used. Of the 11 bone and decomposed tissue samples tested, 8 resulted in more complete and balanced STR profiles when amplified with the GlobalFiler® kit. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Direct qPCR quantification using the Quantifiler(®) Trio DNA quantification kit.

    PubMed

    Liu, Jason Yingjie

    2014-11-01

    The effectiveness of a direct quantification assay is essential to the adoption of the combined direct quantification/direct STR workflow. In this paper, the feasibility of using the Quantifiler(®) Trio DNA quantification kit for the direct quantification of forensic casework samples was investigated. Both low-level touch DNA samples and blood samples were collected on PE swabs and quantified directly. The increased sensitivity of the Quantifiler(®) Trio kit enabled the detection of less than 10pg of DNA in unprocessed touch samples and also minimizes the stochastic effect experienced by different targets in the same sample. The DNA quantity information obtained from a direct quantification assay using the Quantifiler(®) Trio kit can also be used to accurately estimate the optimal input DNA quantity for a direct STR amplification reaction. The correlation between the direct quantification results (Quantifiler(®) Trio kit) and the direct STR results (GlobalFiler™ PCR amplification kit(*)) for low-level touch DNA samples indicates that direct quantification using the Quantifiler(®) Trio DNA quantification kit is more reliable than the Quantifiler(®) Duo DNA quantification kit for predicting the STR results of unprocessed touch DNA samples containing less than 10pg of DNA. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. HNU-HANBY PCP IMMUNOASSAY TEST KIT - INNOVATIVE TECHNOLOGY EVALUATION REPORT

    EPA Science Inventory

    The HNU-Hanby pentachlorophenol (PCP) test kit rapidly analyzes for PCP in soil samples. The test kit can only detect those PCP carriers that contain aromatic compounds. The test kit estimates PCP concentrations in soil samples indirectly by measuring petroleum hydrocarbon carrie...

  14. DEMONSTRATION BULLETIN: HNU-HANBY PCP IMMUNOASSAY TEST KIT - HNU - SYSTEMS, INC.

    EPA Science Inventory

    The HNU-Hanby test kit rapidly analyzes for petroleum hydrocarbons in soil and water samples. The test kit can be used to estimate pentachlorophenol (PCP) concentrations in samples when the carrier solvent is a petroleum hydrocarbon. The test kit estimates PCP concentrations in ...

  15. [Validation of Differential Extraction Kit in forensic sexual assault cases].

    PubMed

    Wu, Dan; Cao, Yu; Xu, Yan; He, Bai-Fang; Bi, Gang; Zhou, Huai-Gu

    2009-12-01

    To evaluate the validity of Differential Extraction Kit in isolating spermatozoa and epithelial cell DNA from mixture samples. Selective lysis of spermatid and epithelial cells combined with paramagnetic particle method were applied to extract the DNA from the mock samples under controlled conditions and forensic case samples, and template DNA were analyzed by STR genotype method. This Differential Extraction Kit is efficient to obtain high quality spermatid and epithelial cell DNA from the mixture samples with different proportion of sperm to epithelial cell. The Differential Extraction Kit can be applied in DNA extraction for mixed stain from forensic sexual assault samples.

  16. The impact of different DNA extraction kits and laboratories upon the assessment of human gut microbiota composition by 16S rRNA gene sequencing.

    PubMed

    Kennedy, Nicholas A; Walker, Alan W; Berry, Susan H; Duncan, Sylvia H; Farquarson, Freda M; Louis, Petra; Thomson, John M; Satsangi, Jack; Flint, Harry J; Parkhill, Julian; Lees, Charlie W; Hold, Georgina L

    2014-01-01

    Determining bacterial community structure in fecal samples through DNA sequencing is an important facet of intestinal health research. The impact of different commercially available DNA extraction kits upon bacterial community structures has received relatively little attention. The aim of this study was to analyze bacterial communities in volunteer and inflammatory bowel disease (IBD) patient fecal samples extracted using widely used DNA extraction kits in established gastrointestinal research laboratories. Fecal samples from two healthy volunteers (H3 and H4) and two relapsing IBD patients (I1 and I2) were investigated. DNA extraction was undertaken using MoBio Powersoil and MP Biomedicals FastDNA SPIN Kit for Soil DNA extraction kits. PCR amplification for pyrosequencing of bacterial 16S rRNA genes was performed in both laboratories on all samples. Hierarchical clustering of sequencing data was done using the Yue and Clayton similarity coefficient. DNA extracted using the FastDNA kit and the MoBio kit gave median DNA concentrations of 475 (interquartile range 228-561) and 22 (IQR 9-36) ng/µL respectively (p<0.0001). Hierarchical clustering of sequence data by Yue and Clayton coefficient revealed four clusters. Samples from individuals H3 and I2 clustered by patient; however, samples from patient I1 extracted with the MoBio kit clustered with samples from patient H4 rather than the other I1 samples. Linear modelling on relative abundance of common bacterial families revealed significant differences between kits; samples extracted with MoBio Powersoil showed significantly increased Bacteroidaceae, Ruminococcaceae and Porphyromonadaceae, and lower Enterobacteriaceae, Lachnospiraceae, Clostridiaceae, and Erysipelotrichaceae (p<0.05). This study demonstrates significant differences in DNA yield and bacterial DNA composition when comparing DNA extracted from the same fecal sample with different extraction kits. This highlights the importance of ensuring that samples in a study are prepared with the same method, and the need for caution when cross-comparing studies that use different methods.

  17. Point of Care Tuberculosis Sero-Diagnosis Kit for Wild Animals: Combination of Proteins for Improving the Diagnostic Sensitivity and Specificity.

    PubMed

    Veerasami, Maroudam; Venkataraman, K; Karuppannan, Chitra; Shanmugam, Arun Attur; Prudhvi, Mallepaddi Chand; Holder, Thomas; Rathnagiri, Polavarapu; Arunmozhivarman, K; Raj, Gopal Dhinakar; Vordermeier, Martin; Mohana Subramanian, B

    2018-03-01

    Tuberculosis is a significant problem globally for domestic animals as well as captive and free ranging wild life. Rapid point of care (POC) serology kits are well suited for the diagnosis of TB in wild animals. However, wild animals are invariably exposed to environmental non-pathogenic mycobacterium species with the development of cross reacting antibodies. In the present study, POC TB diagnosis kit was developed using a combination of pathogenic Mycobacteria specific recombinant antigens and purified protein derivatives of pathogenic and non-pathogenic Mycobacteria . To benchmark the TB antibody detection kit, particularly in respect to specificity which could not be determined in wildlife due to the lack of samples from confirmed uninfected animals, we first tested well-characterized sera from 100 M. bovis infected and 100 uninfected cattle. Then we investigated the kit's performance using sera samples from wildlife, namely Sloth Bears (n = 74), Elephants (n = 9), Cervidae (n = 14), Felidae (n = 21), Cape buffalo (n = 2), Wild bear (n = 1) and Wild dog (n = 1).In cattle, a sensitivity of 81% and a specificity of 90% were obtained. The diagnostic sensitivity of the kit was 94% when the kit was tested using known TB positive sloth bear sera samples. 47.4% of the in-contact sloth bears turned seropositive using the rapid POC TB diagnostic kit. Seropositivity in other wild animals was 25% when the sera samples were tested using the kit. A point of care TB sero-diagnostic kit with the combination of proteins was developed and the kit was validated using the sera samples of wild animals.

  18. Comparison of methods for the extraction of DNA from formalin-fixed, paraffin-embedded archival tissues.

    PubMed

    Sengüven, Burcu; Baris, Emre; Oygur, Tulin; Berktas, Mehmet

    2014-01-01

    Discussing a protocol involving xylene-ethanol deparaffinization on slides followed by a kit-based extraction that allows for the extraction of high quality DNA from FFPE tissues. DNA was extracted from the FFPE tissues of 16 randomly selected blocks. Methods involving deparaffinization on slides or tubes, enzyme digestion overnight or for 72 hours and isolation using phenol chloroform method or a silica-based commercial kit were compared in terms of yields, concentrations and the amplifiability. The highest yield of DNA was produced from the samples that were deparaffinized on slides, digested for 72 hours and isolated with a commercial kit. Samples isolated with the phenol-chloroform method produced DNA of lower purity than the samples that were purified with kit. The samples isolated with the commercial kit resulted in better PCR amplification. Silica-based commercial kits and deparaffinized on slides should be considered for DNA extraction from FFPE.

  19. 76 FR 3119 - Availability for Exclusive, Non-Exclusive, or Partially-Exclusive Licensing of an Invention...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-19

    ... Partially-Exclusive Licensing of an Invention Concerning a Urinary Field Sampling Kit for the Determination.... Provisional Patent Application Serial No. 61/458,797, entitled ``Urinary Field Sampling Kit for the... INFORMATION: The invention relates to a urinary field sampling kit and method of its use for collecting and...

  20. Comparison of DNA extraction kits and modification of DNA elution procedure for the quantitation of subdominant bacteria from piggery effluents with real-time PCR

    PubMed Central

    Desneux, Jérémy; Pourcher, Anne-Marie

    2014-01-01

    Four commercial DNA extraction kits and a minor modification in the DNA elution procedure were evaluated for the quantitation of bacteria in pig manure samples. The PowerSoil®, PowerFecal®, NucleoSpin® Soil kits and QIAamp® DNA Stool Mini kit were tested on raw manure samples and on lagoon effluents for their ability to quantify total bacteria and a subdominant bacteria specific of pig manure contamination: Lactobacillus amylovorus. The NucleoSpin® Soil kit (NS kit), and to a lesser extent the PowerFecal® kit were the most efficient methods. Regardless of the kit utilized, the modified elution procedure increased DNA yield in the lagoon effluent by a factor of 1.4 to 1.8. When tested on 10 piggery effluent samples, compared to the QIAamp kit, the NS kit combined with the modified elution step, increased by a factor up to 1.7 log10 the values of the concentration of L. amylovorus. Regardless of the type of manure, the best DNA quality and the highest concentrations of bacteria were obtained using the NS kit combined with the modification of the elution procedure. The method recommended here significantly improved quantitation of subdominant bacteria in manure. PMID:24838631

  1. Comparison of DNA extraction methods for human gut microbial community profiling.

    PubMed

    Lim, Mi Young; Song, Eun-Ji; Kim, Sang Ho; Lee, Jangwon; Nam, Young-Do

    2018-03-01

    The human gut harbors a vast range of microbes that have significant impact on health and disease. Therefore, gut microbiome profiling holds promise for use in early diagnosis and precision medicine development. Accurate profiling of the highly complex gut microbiome requires DNA extraction methods that provide sufficient coverage of the original community as well as adequate quality and quantity. We tested nine different DNA extraction methods using three commercial kits (TianLong Stool DNA/RNA Extraction Kit (TS), QIAamp DNA Stool Mini Kit (QS), and QIAamp PowerFecal DNA Kit (QP)) with or without additional bead-beating step using manual or automated methods and compared them in terms of DNA extraction ability from human fecal sample. All methods produced DNA in sufficient concentration and quality for use in sequencing, and the samples were clustered according to the DNA extraction method. Inclusion of bead-beating step especially resulted in higher degrees of microbial diversity and had the greatest effect on gut microbiome composition. Among the samples subjected to bead-beating method, TS kit samples were more similar to QP kit samples than QS kit samples. Our results emphasize the importance of mechanical disruption step for a more comprehensive profiling of the human gut microbiome. Copyright © 2017 The Authors. Published by Elsevier GmbH.. All rights reserved.

  2. Optimising the diagnostic strategy for onychomycosis from sample collection to FUNGAL identification evaluation of a diagnostic kit for real-time PCR.

    PubMed

    Petinataud, Dimitri; Berger, Sibel; Ferdynus, Cyril; Debourgogne, Anne; Contet-Audonneau, Nelly; Machouart, Marie

    2016-05-01

    Onychomycosis is a common nail disorder mainly due to dermatophytes for which the conventional diagnosis requires direct microscopic observation and culture of a biological sample. Nevertheless, antifungal treatments are commonly prescribed without a mycological examination having been performed, partly because of the slow growth of dermatophytes. Therefore, molecular biology has been applied to this pathology, to support a quick and accurate distinction between onychomycosis and other nail damage. Commercial kits are now available from several companies for improving traditional microbiological diagnosis. In this paper, we present the first evaluation of the real-time PCR kit marketed by Bio Evolution for the diagnosis of dermatophytosis. Secondly, we compare the efficacy of the kit on optimal and non-optimal samples. This study was conducted on 180 nails samples, processed by conventional methods and retrospectively analysed using this kit. According to our results, this molecular kit has shown high specificity and sensitivity in detecting dermatophytes, regardless of sample quality. On the other hand, and as expected, optimal samples allowed the identification of a higher number of dermatophytes by conventional mycological diagnosis, compared to non-optimal samples. Finally, we have suggested several strategies for the practical use of such a kit in a medical laboratory for quick pathogen detection. © 2016 Blackwell Verlag GmbH.

  3. Comparison of Methods for the Extraction of DNA from Formalin-Fixed, Paraffin-Embedded Archival Tissues

    PubMed Central

    Sengüven, Burcu; Baris, Emre; Oygur, Tulin; Berktas, Mehmet

    2014-01-01

    Aim: Discussing a protocol involving xylene-ethanol deparaffinization on slides followed by a kit-based extraction that allows for the extraction of high quality DNA from FFPE tissues. Methods: DNA was extracted from the FFPE tissues of 16 randomly selected blocks. Methods involving deparaffinization on slides or tubes, enzyme digestion overnight or for 72 hours and isolation using phenol chloroform method or a silica-based commercial kit were compared in terms of yields, concentrations and the amplifiability. Results: The highest yield of DNA was produced from the samples that were deparaffinized on slides, digested for 72 hours and isolated with a commercial kit. Samples isolated with the phenol-chloroform method produced DNA of lower purity than the samples that were purified with kit. The samples isolated with the commercial kit resulted in better PCR amplification. Conclusion: Silica-based commercial kits and deparaffinized on slides should be considered for DNA extraction from FFPE. PMID:24688314

  4. [Determination of Hair Shafts by InnoTyper® 21 Kit].

    PubMed

    Li, F; Zhang, M; Wang, Y X; Shui, J J; Yan, M; Jin, X P; Zhu, X J

    2017-12-01

    To explore the application value of InnoTyper® 21 kit in forensic practice. Samples of hair shafts and saliva were collected from 8 unrelated individuals. Template DNA was extracted by AutoMate Express™ forensic DNA automatic extraction system. DNA was amplified by InnoTyper® 21 kit and AmpFℓSTR™ Identifiler™ Plus kit, respectively, and then the results were compared. After the amplification by InnoTyper® 21 kit, complete specific genotyping could be detected from the saliva samples, and the peak value of genotyping profiles of hair shafts without sheath cells was 57-1 219 RFU. Allelic gene deletion could be found sometimes. When amplified by AmpFℓSTR™ Identifiler™ Plus kit, complete specific genotyping could be detected from the saliva samples, and the specific fragment was not detected in hair shafts without sheath cells. The InnoTyper® 21 kit has certain application value in the cases of hair shafts without sheath cells. Copyright© by the Editorial Department of Journal of Forensic Medicine

  5. Performance Tested Method multiple laboratory validation study of ELISA-based assays for the detection of peanuts in food.

    PubMed

    Park, Douglas L; Coates, Scott; Brewer, Vickery A; Garber, Eric A E; Abouzied, Mohamed; Johnson, Kurt; Ritter, Bruce; McKenzie, Deborah

    2005-01-01

    Performance Tested Method multiple laboratory validations for the detection of peanut protein in 4 different food matrixes were conducted under the auspices of the AOAC Research Institute. In this blind study, 3 commercially available ELISA test kits were validated: Neogen Veratox for Peanut, R-Biopharm RIDASCREEN FAST Peanut, and Tepnel BioKits for Peanut Assay. The food matrixes used were breakfast cereal, cookies, ice cream, and milk chocolate spiked at 0 and 5 ppm peanut. Analyses of the samples were conducted by laboratories representing industry and international and U.S governmental agencies. All 3 commercial test kits successfully identified spiked and peanut-free samples. The validation study required 60 analyses on test samples at the target level 5 microg peanut/g food and 60 analyses at a peanut-free level, which was designed to ensure that the lower 95% confidence limit for the sensitivity and specificity would not be <90%. The probability that a test sample contains an allergen given a prevalence rate of 5% and a positive test result using a single test kit analysis with 95% sensitivity and 95% specificity, which was demonstrated for these test kits, would be 50%. When 2 test kits are run simultaneously on all samples, the probability becomes 95%. It is therefore recommended that all field samples be analyzed with at least 2 of the validated kits.

  6. Limits of diagnostic accuracy of anti-hepatitis C virus antibodies detection by ELISA and immunoblot assay.

    PubMed

    Suslov, Anatoly P; Kuzin, Stanislav N; Golosova, Tatiana V; Shalunova, Nina V; Malyshev, Nikolai A; Sadikova, Natalia V; Vavilova, Lubov M; Somova, Anna V; Musina, Elena E; Ivanova, Maria V; Kipor, Tatiana T; Timonin, Igor M; Kuzina, Lubov E; Godkov, Mihail A; Bajenov, Alexei I; Nesterenko, Vladimir G

    2002-07-01

    When human sera samples are tested for anti-hepatitis C virus (HCV) antibodies using different ELISA kits as well as immunoblot assay kits discrepant results often occur. As a result the diagnostics of HCV infection in such sera remains unclear. The purpose of this investigation is to define the limits of HCV serodiagnostics. Overall 7 different test kits of domestic and foreign manufacturers were used for the sampled sera testing. Preliminary comparative study, using seroconversion panels PHV905, PHV907, PHV908 was performed and reference kit was chosen (Murex anti-HCV version 4) as the most sensitive kit on the base of this study results. Overall 1640 sera samples have been screened using different anti-HCV ELISA kits and 667 of them gave discrepant results in at least two kits. These sera were then tested using three anti-HCV ELISA kits (first set of 377 samples) or four anti-HCV ELISA kits (second set of 290 samples) at the conditions of reference laboratory. In the first set 17.2% samples remained discrepant and in the second set - 13.4%. "Discrepant" sera were further tested in RIBA 3.0 and INNO-LIA immunoblot confirmatory assays, but approximately 5-7% of them remained undetermined after all the tests. For the samples with signal-to-cutoff ratio higher than 3.0 high rate of result consistency by reference, ELISA routing and INNO-LIA immunoblot assay was observed. On the other hand the results of tests 27 "problematic" sera in RIBA 3.0 and INNO-LIA were consistent only in 55.5% cases. Analysis of the antigen spectrum reactive with antibodies in "problematic" sera, demonstrated predominance of Core, NS3 and NS4 antigens for sera, positive in RIBA 3.0 and Core and NS3 antigens for sera, positive in INNO-LIA. To overcome the problem of undetermined sera, methods based on other principles, as well as alternative criteria of HCV infection diagnostics are discussed.

  7. 30 CFR 7.405 - Critical characteristics.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Cable Splice Kits § 7.405 Critical characteristics. (a) A sample from each production run, batch, or lot of manufactured electric cable, signaling cable, or splice made from a splice kit shall be flame... cable or splice and a sample of the cable or splice kit assembly shall be visually inspected or tested...

  8. 30 CFR 7.405 - Critical characteristics.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Cable Splice Kits § 7.405 Critical characteristics. (a) A sample from each production run, batch, or lot of manufactured electric cable, signaling cable, or splice made from a splice kit shall be flame... cable or splice and a sample of the cable or splice kit assembly shall be visually inspected or tested...

  9. Comparison of DNA extraction protocols for microbial communities from soil treated with biochar

    PubMed Central

    Leite, D.C.A.; Balieiro, F.C.; Pires, C.A.; Madari, B.E.; Rosado, A.S.; Coutinho, H.L.C.; Peixoto, R.S.

    2014-01-01

    Many studies have evaluated the effects of biochar application on soil structure and plant growth. However, there are very few studies describing the effect of biochar on native soil microbial communities. Microbial analysis of environmental samples requires accurate and reproducible methods for the extraction of DNA from samples. Because of the variety among microbial species and the strong adsorption of the phosphate backbone of the DNA molecule to biochar, extracting and purifying high quality microbial DNA from biochar-amended soil is not a trivial process and can be considerably more difficult than the extraction of DNA from other environmental samples. The aim of this study was to compare the relative efficacies of three commercial DNA extraction kits, the FastDNA® SPIN Kit for Soil (FD kit), the PowerSoil® DNA Isolation Kit (PS kit) and the ZR Soil Microbe DNA Kit Miniprep™ (ZR kit), for extracting microbial genomic DNA from sand treated with different types of biochar. The methods were evaluated by comparing the DNA yields and purity and by analysing the bacterial and fungal community profiles generated by PCR-DGGE. Our results showed that the PCR-DGGE profiles for bacterial and fungal communities were highly affected by the purity and yield of the different DNA extracts. Among the tested kits, the PS kit was the most efficient with respect to the amount and purity of recovered DNA and considering the complexity of the generated DGGE microbial fingerprint from the sand-biochar samples. PMID:24948928

  10. Comparison of DNA extraction protocols for microbial communities from soil treated with biochar.

    PubMed

    Leite, D C A; Balieiro, F C; Pires, C A; Madari, B E; Rosado, A S; Coutinho, H L C; Peixoto, R S

    2014-01-01

    Many studies have evaluated the effects of biochar application on soil structure and plant growth. However, there are very few studies describing the effect of biochar on native soil microbial communities. Microbial analysis of environmental samples requires accurate and reproducible methods for the extraction of DNA from samples. Because of the variety among microbial species and the strong adsorption of the phosphate backbone of the DNA molecule to biochar, extracting and purifying high quality microbial DNA from biochar-amended soil is not a trivial process and can be considerably more difficult than the extraction of DNA from other environmental samples. The aim of this study was to compare the relative efficacies of three commercial DNA extraction kits, the FastDNA® SPIN Kit for Soil (FD kit), the PowerSoil® DNA Isolation Kit (PS kit) and the ZR Soil Microbe DNA Kit Miniprep™ (ZR kit), for extracting microbial genomic DNA from sand treated with different types of biochar. The methods were evaluated by comparing the DNA yields and purity and by analysing the bacterial and fungal community profiles generated by PCR-DGGE. Our results showed that the PCR-DGGE profiles for bacterial and fungal communities were highly affected by the purity and yield of the different DNA extracts. Among the tested kits, the PS kit was the most efficient with respect to the amount and purity of recovered DNA and considering the complexity of the generated DGGE microbial fingerprint from the sand-biochar samples.

  11. Correlation Between Iron and alpha and pi Glutathione-S-Transferase Levels in Humans

    DTIC Science & Technology

    2012-09-01

    assays were performed as described in the Biotrin High Sensitivity Alpha GST EIA kit protocol. First, serum samples were diluted 1:10 with wash solution...immunosorbent assays were performed as described in the Biotrin Pi GST EIA kit protocol. First, plasma samples were diluted 1:5 with sample diluent...immunosorbent assays were performed as described in the AssayMax Human Transferrin ELISA kit protocol. First, serum samples were diluted 1:2000 with MIX

  12. Facilitators and Barriers to Naloxone Kit Use Among Opioid-Dependent Patients Enrolled in Medication Assisted Therapy Clinics in North Carolina.

    PubMed

    Khatiwoda, Prasana; Proeschold-Bell, Rae Jean; Meade, Christina S; Park, Lawrence P; Proescholdbell, Scott

    2018-01-01

    BACKGROUND Naloxone-an opioid antagonist that reverses the effects of opioids-is increasingly being distributed in non-medical settings. We sought to identify the facilitators of, and barriers to, opioid users using naloxone kits in North Carolina. METHODS In 2015, we administered a 15-item survey to a convenience sample of 100 treatment seekers at 4 methadone/buprenorphine Medication Assisted Therapy (MAT) clinics in North Carolina. RESULTS Seventy-four percent of participants reported having ever gotten a naloxone kit; this percentage was higher for females (81%) than males (63%) ( P = .06). The primary reason given for not having a kit was not knowing where to get one. Only 6% had heard of kits from the media and only 5% received one from a medical provider. Among kit recipients, 56% of both females and males reported mostly or sometimes carrying the kit, with additional participants reporting always. Reasons for not carrying a kit were no longer being around drugs, forgetting it, and the kit being too large. Men discussed the difficulties of carrying the naloxone kits, which are currently too large to fit in a pocket. Ninety-four percent of naloxone users reported intending to call emergency services in case of an overdose emergency. LIMITATIONS Study limitations included a small sample, participants limited to MAT clinics, and a predominantly white sample. CONCLUSIONS MAT treatment seekers reported a willingness to carry and use naloxone kits. Education, outreach, media, and medical providers need to promote naloxone kits. A smaller kit may increase the likelihood of men carrying one. ©2018 by the North Carolina Institute of Medicine and The Duke Endowment. All rights reserved.

  13. Evaluation of the LIVE/DEAD BacLight Kit for Detection of Extremophilic Archaea and Visualization of Microorganisms in Environmental Hypersaline Samples

    PubMed Central

    Leuko, Stefan; Legat, Andrea; Fendrihan, Sergiu; Stan-Lotter, Helga

    2004-01-01

    Extremophilic archaea were stained with the LIVE/DEAD BacLight kit under conditions of high ionic strength and over a pH range of 2.0 to 9.3. The reliability of the kit was tested with haloarchaea following permeabilization of the cells. Microorganisms in hypersaline environmental samples were detectable with the kit, which suggests its potential application to future extraterrestrial halites. PMID:15528557

  14. Disposable collection kit for rapid and reliable collection of saliva.

    PubMed

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R(2)  > 0.96). The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. © 2015 Wiley Periodicals, Inc.

  15. Hypocretin measurement: shelf age of radioimmunoassay kit, but not freezer time, influences assay variability.

    PubMed

    Keating, Glenda; Bliwise, Donald L; Saini, Prabhjyot; Rye, David B; Trotti, Lynn Marie

    2017-09-01

    The hypothalamic peptide hypocretin 1 (orexin A) may be assayed in cerebrospinal fluid to diagnose narcolepsy type 1. This testing is not commercially available, and factors contributing to assay variability have not previously been comprehensively explored. In the present study, cerebrospinal fluid hypocretin concentrations were determined in duplicate in 155 patient samples, across a range of sleep disorders. Intra-assay variability of these measures was analyzed. Inter-assay correlation between samples tested at Emory and at Stanford was high (r = 0.79, p < 0.0001). Intra-assay correlation between samples tested in duplicate in our center was also high (r = 0.88, p < 0.0001); intra-assay variability, expressed as the difference between values as a percentage of the higher value, was low at 9.4% (SD = 7.9%). Although both time the sample spent in the freezer (r = 0.16, p = 0.04) and age of the kit used for assay (t = 3.64, p = 0.0004) were significant predictors of intra-kit variability in univariate analyses, only age of kit was significant in multivariate linear regression (F = 4.93, p = 0.03). Age of radioimmunoassay kit affects intra-kit variability of measured hypocretin values, such that kits closer to expiration exhibit significantly more variability.

  16. Evaluation of commercial kit based on loop-mediated isothermal amplification for rapid detection of low levels of uninjured and injured Salmonella on duck meat, bean sprouts, and fishballs in Singapore.

    PubMed

    Lim, Hazel Sin Yue; Zheng, Qianwang; Miks-Krajnik, Marta; Turner, Matthew; Yuk, Hyun-Gyun

    2015-06-01

    The objective of this study was to evaluate performance of the commercial kit based on loop-mediated isothermal amplification (LAMP) in comparison with the International Organization for Standardization method for detecting uninjured and sublethally injured Salmonella cells artificially inoculated at levels of 10(0) and 10(1) CFU/25 g on raw duck wing, raw mung bean sprouts, and processed fishballs. Injured cells were prepared by a heat treatment for duck wings and fishball samples and a chlorine treatment for bean sprout samples. Additionally, a validation study was performed on naturally contaminated food samples sold in Singapore. A total of 110 samples of each commodity were analyzed in this study. Regardless of inoculum levels, the detection by the commercial LAMP kit showed 100% sensitivity and specificity for both inoculated and uninoculated samples compared with the International Organization for Standardization method, with the exception of bean sprout samples. Only 20% of bean sprout samples inoculated with 10(0) CFU/25 g injured Salmonella cells were positive by using the commercial LAMP-based kit. However, all negative samples became positive following a secondary enrichment in Rappaport-Vassiliadis medium with soy broth or after concentration by centrifugation. These results suggest that secondary enrichment or centrifugation should be considered as an additional step to increase the sensitivity of the commercial LAMP-based kit with low numbers of injured target cells in samples with high background microflora (such as mung bean sprouts). The validation study also showed that the commercial LAMP-based kit provided 91% sensitivity and 95% specificity for naturally contaminated samples. Thus, this study demonstrates that the commercial LAMP-based kit might be a cost-effective method, as this system could provide rapid, accurate detection of both uninjured and injured Salmonella cells on raw duck wings, raw mung bean sprouts, and processed fishballs in less than 26 h.

  17. Disposable Collection Kit for Rapid and Reliable Collection of Saliva

    PubMed Central

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    Objectives To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. Methods The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. Results The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R2 > 0.96). Conclusions The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. Am. J. Hum. Biol. 27:720–723, 2015. © 2015 The Authors American Journal of Human Biology Published by Wiley Periodicals, Inc. PMID:25754371

  18. Comparison of Quantifiler(®) Trio and InnoQuant™ human DNA quantification kits for detection of DNA degradation in developed and aged fingerprints.

    PubMed

    Goecker, Zachary C; Swiontek, Stephen E; Lakhtakia, Akhlesh; Roy, Reena

    2016-06-01

    The development techniques employed to visualize fingerprints collected from crime scenes as well as post-development ageing may result in the degradation of the DNA present in low quantities in such evidence samples. Amplification of the DNA samples with short tandem repeat (STR) amplification kits may result in partial DNA profiles. A comparative study of two commercially available quantification kits, Quantifiler(®) Trio and InnoQuant™, was performed on latent fingerprint samples that were either (i) developed using one of three different techniques and then aged in ambient conditions or (ii) undeveloped and then aged in ambient conditions. The three fingerprint development techniques used were: cyanoacrylate fuming, dusting with black powder, and the columnar-thin-film (CTF) technique. In order to determine the differences between the expected quantities and actual quantities of DNA, manually degraded samples generated by controlled exposure of DNA standards to ultraviolet radiation were also analyzed. A total of 144 fingerprint and 42 manually degraded DNA samples were processed in this study. The results indicate that the InnoQuant™ kit is capable of producing higher degradation ratios compared to the Quantifiler(®) Trio kit. This was an expected result since the degradation ratio is a relative value specific for a kit based on the length and extent of amplification of the two amplicons that vary from one kit to the other. Additionally, samples with lower concentrations of DNA yielded non-linear relationships of degradation ratio with the duration of aging, whereas samples with higher concentrations of DNA yielded quasi-linear relationships. None of the three development techniques produced a noticeably different degradation pattern when compared to undeveloped fingerprints, and therefore do not impede downstream DNA analysis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Prognostic significance of c-KIT in vulvar cancer: bringing this molecular marker from bench to bedside

    PubMed Central

    2012-01-01

    Background Vulvar carcinomas are rare tumors, and there is limited data regarding molecular alterations. To our knowledge there are no published studies on c-KIT and squamous cell carcinomas of the vulva (VSCC). Although there are a significant number of other tumor types which express c-KIT, there remains controversy as to its relationship to patient outcome. Thus, we wished to investigate such controversial findings to determine the prognostic importance of c-KIT by evaluating its protein and mRNA expression in VSCCs, correlating these findings with clinicopathological features and Human Papillomavirus (HPV) infection. Methods c-KIT expression was scored by immunohistochemistry (IHC) as positive or negative in 139 formalin-fixed paraffin-embedded (FFPE) cases of vulvar carcinomas arrayed in a tissue microarray (TMA) using the DAKO® A4502 rabbit polyclonal c-KIT antibody (diluted 1:100). c-KIT mRNA was evaluated by qRT-PCR in 34 frozen samples from AC Camargo Hospital Biobank (17 tumoral and 17 non-tumoral samples) using TaqMan probes–Applied Biosystems [Hs00174029_m1]. HPV genotyping was assessed in 103 samples using Linear Array® HPV Genotyping Test kit (Roche Molecular Diagnostics, Basel, Switzerland). All results obtained were correlated with clinical and pathological data of the patients. Results c-KIT protein was positive by immunohistochemistry in 70.5% of the cases and this was associated with a higher global survival (p = 0.007), a higher recurrence-free survival (p < 0.0001), an absence of associated lesions (p = 0.001), lymph node metastasis (p = 0.0053), and HPV infection (p = 0.034). Furthermore, c-KIT mRNA quantitation revealed higher levels of transcripts in normal samples compared to tumor samples (p = 0,0009). Conclusions Our findings indicate that those vulvar tumors staining positively for c-KIT present better prognosis. Thus, positivity of c-KIT as evaluated by IHC may be a good predictor for use of more conservative surgery techniques and lymph node dissection in vulvar cancer. So part of the essence of our study is to see the possibility of translating our current results from the bench to the bedside. This will help provide patients a more appropriate, less mutilating treatment, in order to keep the maximum physical and psychic quality as possible to these women. PMID:22839358

  20. Optimising the quantification of cytokines present at low concentrations in small human mucosal tissue samples using Luminex assays☆

    PubMed Central

    Staples, Emily; Ingram, Richard James Michael; Atherton, John Christopher; Robinson, Karen

    2013-01-01

    Sensitive measurement of multiple cytokine profiles from small mucosal tissue biopsies, for example human gastric biopsies obtained through an endoscope, is technically challenging. Multiplex methods such as Luminex assays offer an attractive solution but standard protocols are not available for tissue samples. We assessed the utility of three commercial Luminex kits (VersaMAP, Bio-Plex and MILLIPLEX) to measure interleukin-17A (IL-17) and interferon-gamma (IFNγ) concentrations in human gastric biopsies and we optimised preparation of mucosal samples for this application. First, we assessed the technical performance, limits of sensitivity and linear dynamic ranges for each kit. Next we spiked human gastric biopsies with recombinant IL-17 and IFNγ at a range of concentrations (1.5 to 1000 pg/mL) and assessed kit accuracy for spiked cytokine recovery and intra-assay precision. We also evaluated the impact of different tissue processing methods and extraction buffers on our results. Finally we assessed recovery of endogenous cytokines in unspiked samples. In terms of sensitivity, all of the kits performed well within the manufacturers' recommended standard curve ranges but the MILLIPLEX kit provided most consistent sensitivity for low cytokine concentrations. In the spiking experiments, the MILLIPLEX kit performed most consistently over the widest range of concentrations. For tissue processing, manual disruption provided significantly improved cytokine recovery over automated methods. Our selected kit and optimised protocol were further validated by measurement of relative cytokine levels in inflamed and uninflamed gastric mucosa using Luminex and real-time polymerase chain reaction. In summary, with proper optimisation Luminex kits (and for IL-17 and IFNγ the MILLIPLEX kit in particular) can be used for the sensitive detection of cytokines in mucosal biopsies. Our results should help other researchers seeking to quantify multiple low concentration cytokines in small tissue samples. PMID:23644159

  1. Experiment kits for processing biological samples inflight on SLS-2

    NASA Technical Reports Server (NTRS)

    Savage, P. D.; Hinds, W. E.; Jaquez, R.; Evans, J.; Dubrovin, L.

    1995-01-01

    This paper describes development of an innovative, modular approach to packaging the instruments used to obtain and preserve the inflight rodent tissue and blood samples associated with hematology experiments on the Spacelab Life Sciences-2 (SLS-2) mission. The design approach organized the multitude of instruments into twelve 5- x 6- x l-in. kits which were each used for a particular experiment. Each kit contained the syringes, vials, microscope slides, etc., necessary for processing and storing blood and tissue samples for one rat on a particular day. A total of 1245 components, packaged into 128 kits and stowed in 17 Zero(registered trademark) boxes, were required. Crewmembers found the design easy to use and laid out in a logical, simple configuration which minimized chances for error during the complex procedures in flight. This paper also summarizes inflight performance of the kits on SLS-2.

  2. 10 CFR 429.33 - Ceiling fan light kits.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Ceiling fan light kits. 429.33 Section 429.33 Energy... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.33 Ceiling fan light kits. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to ceiling fan light kits...

  3. 10 CFR 429.33 - Ceiling fan light kits.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Ceiling fan light kits. 429.33 Section 429.33 Energy... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.33 Ceiling fan light kits. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to ceiling fan light kits...

  4. 10 CFR 429.33 - Ceiling fan light kits.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Ceiling fan light kits. 429.33 Section 429.33 Energy... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.33 Ceiling fan light kits. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to ceiling fan light kits...

  5. Loss of c-KIT expression in thyroid cancer cells.

    PubMed

    Franceschi, Sara; Lessi, Francesca; Panebianco, Federica; Tantillo, Elena; La Ferla, Marco; Menicagli, Michele; Aretini, Paolo; Apollo, Alessandro; Naccarato, Antonio Giuseppe; Marchetti, Ivo; Mazzanti, Chiara Maria

    2017-01-01

    Papillary thyroid carcinoma is the most frequent histologic type of thyroid tumor. Few studies investigated the role of c-KIT expression in thyroid tumors, suggesting a role for this receptor and its ligand in differentiation and growth control of thyroid epithelium and a receptor loss following malignant transformation. We investigated and correlated c-KIT expression levels and two known markers of thyrocytes differentiation, PAX8 and TTF-1, in malignant and benign cytological thyroid samples. Moreover, we performed functional studies on human papillary thyroid carcinoma cell line to associated c-KIT expression to thyrocytes differentiation and tumor proliferation. c-KIT and PAX8 expression resulted higher in benign samples compared to the malignant ones, and the expression levels of these two genes were significantly correlated to each other. We also observed that c-KIT overexpression led to an increase of PAX8 expression level together with a decrease of proliferation. Furthermore, c-KIT overexpressing cells showed a regression of typical morphological features of malignancy. Taken together these results suggest that c-KIT could be involved in the differentiation of thyroid cells and in tumor progression.

  6. Loss of c-KIT expression in thyroid cancer cells

    PubMed Central

    Panebianco, Federica; Tantillo, Elena; La Ferla, Marco; Menicagli, Michele; Aretini, Paolo; Apollo, Alessandro; Naccarato, Antonio Giuseppe; Marchetti, Ivo; Mazzanti, Chiara Maria

    2017-01-01

    Papillary thyroid carcinoma is the most frequent histologic type of thyroid tumor. Few studies investigated the role of c-KIT expression in thyroid tumors, suggesting a role for this receptor and its ligand in differentiation and growth control of thyroid epithelium and a receptor loss following malignant transformation. We investigated and correlated c-KIT expression levels and two known markers of thyrocytes differentiation, PAX8 and TTF-1, in malignant and benign cytological thyroid samples. Moreover, we performed functional studies on human papillary thyroid carcinoma cell line to associated c-KIT expression to thyrocytes differentiation and tumor proliferation. c-KIT and PAX8 expression resulted higher in benign samples compared to the malignant ones, and the expression levels of these two genes were significantly correlated to each other. We also observed that c-KIT overexpression led to an increase of PAX8 expression level together with a decrease of proliferation. Furthermore, c-KIT overexpressing cells showed a regression of typical morphological features of malignancy. Taken together these results suggest that c-KIT could be involved in the differentiation of thyroid cells and in tumor progression. PMID:28301608

  7. Factors for C-Kit Expression in Cardiac Outgrowth Cells and Human Heart Tissue.

    PubMed

    Matsushita, Satoshi; Minematsu, Kazuo; Yamamoto, Taira; Inaba, Hirotaka; Kuwaki, Kenji; Shimada, Akie; Yokoyama, Yasutaka; Amano, Atsushi

    2017-12-12

    We determined the factors associated with the expression of c-kit in the heart and the proliferation of c-kit-positive (c-kit pos ) cardiac stem cells among the outgrowth cells cultured from human cardiac explants.Samples of the right atrium (RA), left atrium (LA), and left ventricle obtained from patients during open-heart surgery were processed for cell culture of outgrowth cells and tissue analysis. The total number of growing cells and the population of c-kit pos cells were measured and compared with c-kit expression in native tissues and characteristics of the patients according to the region of the heart.We analyzed 452 samples from 334 patients. Atrial fibrillation (AF) in the patients reduced the number of outgrowth cells from the RA and LA, and aging was a co-factor for the LA. The c-kit pos population from the RA was associated with serum brain natriuretic peptide (BNP). C-kit expression in native tissue was also associated with BNP expression. However, we observed no relationship in expression between outgrowth cells and native tissue. In addition, the RA tissue provided the highest number of c-kit pos cells, and the left ventricle provided the lowest.C-kit was weakly expressed in response to damage. In addition, no correlation between outgrowth cells and native tissue was found for c-kit expression.

  8. Quantification of Parvovirus B19 DNA Using COBAS AmpliPrep Automated Sample Preparation and LightCycler Real-Time PCR

    PubMed Central

    Schorling, Stefan; Schalasta, Gunnar; Enders, Gisela; Zauke, Michael

    2004-01-01

    The COBAS AmpliPrep instrument (Roche Diagnostics GmbH, D-68305 Mannheim, Germany) automates the entire sample preparation process of nucleic acid isolation from serum or plasma for polymerase chain reaction analysis. We report the analytical performance of the LightCycler Parvovirus B19 Quantification Kit (Roche Diagnostics) using nucleic acids isolated with the COBAS AmpliPrep instrument. Nucleic acids were extracted using the Total Nucleic Acid Isolation Kit (Roche Diagnostics) and amplified with the LightCycler Parvovirus B19 Quantification Kit. The kit combination processes 72 samples per 8-hour shift. The lower detection limit is 234 IU/ml at a 95% hit-rate, linear range approximately 104-1010 IU/ml, and overall precision 16 to 40%. Relative sensitivity and specificity in routine samples from pregnant women are 100% and 93%, respectively. Identification of a persistent parvovirus B19-infected individual by the polymerase chain reaction among 51 anti-parvovirus B19 IgM-negative samples underlines the importance of additional nucleic acid testing in pregnancy and its superiority to serology in identifying the risk of parvovirus B19 transmission via blood or blood products. Combination of the Total Nucleic Acid Isolation Kit on the COBAS AmpliPrep instrument with the LightCycler Parvovirus B19 Quantification Kit provides a reliable and time-saving tool for sensitive and accurate detection of parvovirus B19 DNA. PMID:14736825

  9. Comparison of microbial DNA enrichment tools for metagenomic whole genome sequencing.

    PubMed

    Thoendel, Matthew; Jeraldo, Patricio R; Greenwood-Quaintance, Kerryl E; Yao, Janet Z; Chia, Nicholas; Hanssen, Arlen D; Abdel, Matthew P; Patel, Robin

    2016-08-01

    Metagenomic whole genome sequencing for detection of pathogens in clinical samples is an exciting new area for discovery and clinical testing. A major barrier to this approach is the overwhelming ratio of human to pathogen DNA in samples with low pathogen abundance, which is typical of most clinical specimens. Microbial DNA enrichment methods offer the potential to relieve this limitation by improving this ratio. Two commercially available enrichment kits, the NEBNext Microbiome DNA Enrichment Kit and the Molzym MolYsis Basic kit, were tested for their ability to enrich for microbial DNA from resected arthroplasty component sonicate fluids from prosthetic joint infections or uninfected sonicate fluids spiked with Staphylococcus aureus. Using spiked uninfected sonicate fluid there was a 6-fold enrichment of bacterial DNA with the NEBNext kit and 76-fold enrichment with the MolYsis kit. Metagenomic whole genome sequencing of sonicate fluid revealed 13- to 85-fold enrichment of bacterial DNA using the NEBNext enrichment kit. The MolYsis approach achieved 481- to 9580-fold enrichment, resulting in 7 to 59% of sequencing reads being from the pathogens known to be present in the samples. These results demonstrate the usefulness of these tools when testing clinical samples with low microbial burden using next generation sequencing. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Improved technical success and radiation safety of adrenal vein sampling using rapid, semi-quantitative point-of-care cortisol measurement.

    PubMed

    Page, Michael M; Taranto, Mario; Ramsay, Duncan; van Schie, Greg; Glendenning, Paul; Gillett, Melissa J; Vasikaran, Samuel D

    2018-01-01

    Objective Primary aldosteronism is a curable cause of hypertension which can be treated surgically or medically depending on the findings of adrenal vein sampling studies. Adrenal vein sampling studies are technically demanding with a high failure rate in many centres. The use of intraprocedural cortisol measurement could improve the success rates of adrenal vein sampling but may be impracticable due to cost and effects on procedural duration. Design Retrospective review of the results of adrenal vein sampling procedures since commencement of point-of-care cortisol measurement using a novel single-use semi-quantitative measuring device for cortisol, the adrenal vein sampling Accuracy Kit. Success rate and complications of adrenal vein sampling procedures before and after use of the adrenal vein sampling Accuracy Kit. Routine use of the adrenal vein sampling Accuracy Kit device for intraprocedural measurement of cortisol commenced in 2016. Results Technical success rate of adrenal vein sampling increased from 63% of 99 procedures to 90% of 48 procedures ( P = 0.0007) after implementation of the adrenal vein sampling Accuracy Kit. Failure of right adrenal vein cannulation was the main reason for an unsuccessful study. Radiation dose decreased from 34.2 Gy.cm 2 (interquartile range, 15.8-85.9) to 15.7 Gy.cm 2 (6.9-47.3) ( P = 0.009). No complications were noted, and implementation costs were minimal. Conclusions Point-of-care cortisol measurement during adrenal vein sampling improved cannulation success rates and reduced radiation exposure. The use of the adrenal vein sampling Accuracy Kit is now standard practice at our centre.

  11. Validation of spot-testing kits to determine iodine content in salt.

    PubMed Central

    Pandav, C. S.; Arora, N. K.; Krishnan, A.; Sankar, R.; Pandav, S.; Karmarkar, M. G.

    2000-01-01

    Iodine deficiency disorders are a major public health problem, and salt iodization is the most widely practised intervention for their elimination. For the intervention to be successful and sustainable, it is vital to monitor the iodine content of salt regularly. Iodometric titration, the traditional method for measuring iodine content, has problems related to accessibility and cost. The newer spot-testing kits are inexpensive, require minimal training, and provide immediate results. Using data from surveys to assess the availability of iodized salt in two states in India, Madhya Pradesh and the National Capital Territory of Delhi, we tested the suitability of such a kit in field situations. Salt samples from Delhi were collected from 30 schools, chosen using the Expanded Programme on Immunization (EPI) cluster sampling technique. A single observer made the measurement for iodine content using the kit. Salt samples from Madhya Pradesh were from 30 rural and 30 urban clusters, identified by using census data and the EPI cluster sampling technique. In each cluster, salt samples were collected from 10 randomly selected households and all retailers. The 15 investigators performing the survey estimated the iodine content of salt samples in the field using the kit. All the samples were brought to the central laboratory in Delhi, where iodine content was estimated using iodometric titration as a reference method. The agreement between the kit and titration values decreased as the number of observers increased. Although sensitivity was not much affected by the increase in the number of observers (93.3% for a single observer and 93.9% for multiple observers), specificity decreased sharply (90.4% for a single observer and 40.4% for multiple observers). Due to the low specificity and resulting high numbers of false-positives for the kit when used by multiple observers ("real-life situations"), kits were likely to consistently overestimate the availability of iodized salt. This overestimation could result in complacency. Therefore, we conclude that until a valid alternative is available, the titration method should be used for monitoring the iodine content of salt at all levels, from producer to consumer, to ensure effectiveness of the programme. PMID:10994281

  12. Evaluation of expression and function of vascular endothelial growth factor receptor 2, platelet derived growth factor receptors-alpha and -beta, KIT, and RET in canine apocrine gland anal sac adenocarcinoma and thyroid carcinoma.

    PubMed

    Urie, Bridget K; Russell, Duncan S; Kisseberth, William C; London, Cheryl A

    2012-05-25

    Toceranib phosphate (Palladia) has a reported objective response rate of 25% in both canine apocrine gland anal sac adenocarcinoma (AGASACA) and thyroid carcinoma (TC), with stable disease occurring in an additional 50-60% of dogs. The basis for the observed responses to toceranib is not known. The purpose of this study was to evaluate AGASACA and TC samples for the expression and activation of VEGFR2, PDGFRα, PDGFRβ, KIT and RET to assess whether dysregulation of these receptor tyrosine kinases (RTKs) may contribute to the biologic activity of toceranib. mRNA for VEGFR2, PDGFRα/β, KIT and RET was detected in all AGASACA samples. mRNA for VEGFR2, PDGFRα/β, and KIT was detected in all TC samples, while mRNA for RET was amplified in 10/15 samples. No phosphorylation of VEGFR2, PDGFRα/β, or KIT was observed on the arrays. However, phosphorylation of RET was detected in 54% of the primary AGASACA and 20% of TC. VEGFR2 was expressed in 19/24 primary and 6/10 metastatic AGASACA and 6/15 TC samples. KIT was present in 8/24 primary and 3/10 metastatic AGASACA and 9/15 TC samples. PDGFRα expression was noted in all tumor samples. In contrast PDGFRβ expression was found in only a few tumor samples but was evident in the stroma of all tumor specimens. Known targets of toceranib are expressed in both AGASAC and TC. Given the observed expression of VEGFR and PDGFRα/β and phosphorylation of RET, these RTKs merit investigation as to their roles in the biology of AGSACA and TC and their contribution to toceranib's activity.

  13. Evaluation of expression and function of vascular endothelial growth factor receptor 2, platelet derived growth factor receptors-alpha and -beta, KIT, and RET in canine apocrine gland anal sac adenocarcinoma and thyroid carcinoma

    PubMed Central

    2012-01-01

    Background Toceranib phosphate (Palladia) has a reported objective response rate of 25% in both canine apocrine gland anal sac adenocarcinoma (AGASACA) and thyroid carcinoma (TC), with stable disease occurring in an additional 50-60% of dogs. The basis for the observed responses to toceranib is not known. The purpose of this study was to evaluate AGASACA and TC samples for the expression and activation of VEGFR2, PDGFRα, PDGFRβ, KIT and RET to assess whether dysregulation of these receptor tyrosine kinases (RTKs) may contribute to the biologic activity of toceranib. Results mRNA for VEGFR2, PDGFRα/β, KIT and RET was detected in all AGASACA samples. mRNA for VEGFR2, PDGFRα/β, and KIT was detected in all TC samples, while mRNA for RET was amplified in 10/15 samples. No phosphorylation of VEGFR2, PDGFRα/β, or KIT was observed on the arrays. However, phosphorylation of RET was detected in 54% of the primary AGASACA and 20% of TC. VEGFR2 was expressed in 19/24 primary and 6/10 metastatic AGASACA and 6/15 TC samples. KIT was present in 8/24 primary and 3/10 metastatic AGASACA and 9/15 TC samples. PDGFRα expression was noted in all tumor samples. In contrast PDGFRβ expression was found in only a few tumor samples but was evident in the stroma of all tumor specimens. Conclusions Known targets of toceranib are expressed in both AGASAC and TC. Given the observed expression of VEGFR and PDGFRα/β and phosphorylation of RET, these RTKs merit investigation as to their roles in the biology of AGSACA and TC and their contribution to toceranib’s activity. PMID:22630170

  14. Evaluation of the Seeplex® Meningitis ACE Detection kit for the detection of 12 common bacterial and viral pathogens of acute meningitis.

    PubMed

    Shin, So Youn; Kwon, Kye Chul; Park, Jong Woo; Kim, Ji Myung; Shin, So Young; Koo, Sun Hoe

    2012-01-01

    Bacterial meningitis is an infectious disease with high rates of mortality and high frequency of severe sequelae. Early identification of causative bacterial and viral pathogens is important for prompt and proper treatment of meningitis and for prevention of life-threatening clinical outcomes. In the present study, we evaluated the value of the Seeplex Meningitis ACE Detection kit (Seegene Inc., Korea), a newly developed multiplex PCR kit employing dual priming oligonucleotide methods, for diagnosing acute meningitis. Analytical sensitivity of the kit was studied using reference strains for each pathogen targeted by the kit, while it's analytical specificity was studied using the human genome DNA and 58 clinically well-identified reference strains. For clinical validation experiment, we used 27 control cerebrospinal fluid (CSF) samples and 78 clinical CSF samples collected from patients at the time of diagnosis of acute meningitis. The lower detection limits ranged from 10(1) copies/µL to 5×10(1) copies/µL for the 12 viral and bacterial pathogens targeted. No cross-reaction was observed. In the validation study, high detection rate of 56.4% was obtained. None of the control samples tested positive, i.e., false-positive results were absent. The Seeplex Meningitis ACE Detection kit showed high sensitivity, specificity, and detection rate for the identification of pathogens in clinical CSF samples. This kit may be useful for rapid identification of important acute meningitis-causing pathogens.

  15. Evaluation of the Seeplex® Meningitis ACE Detection Kit for the Detection of 12 Common Bacterial and Viral Pathogens of Acute Meningitis

    PubMed Central

    Shin, So Youn; Kwon, Kye Chul; Park, Jong Woo; Kim, Ji Myung; Shin, So Young

    2012-01-01

    Background Bacterial meningitis is an infectious disease with high rates of mortality and high frequency of severe sequelae. Early identification of causative bacterial and viral pathogens is important for prompt and proper treatment of meningitis and for prevention of life-threatening clinical outcomes. In the present study, we evaluated the value of the Seeplex Meningitis ACE Detection kit (Seegene Inc., Korea), a newly developed multiplex PCR kit employing dual priming oligonucleotide methods, for diagnosing acute meningitis. Methods Analytical sensitivity of the kit was studied using reference strains for each pathogen targeted by the kit, while it's analytical specificity was studied using the human genome DNA and 58 clinically well-identified reference strains. For clinical validation experiment, we used 27 control cerebrospinal fluid (CSF) samples and 78 clinical CSF samples collected from patients at the time of diagnosis of acute meningitis. Results The lower detection limits ranged from 101 copies/µL to 5×101 copies/µL for the 12 viral and bacterial pathogens targeted. No cross-reaction was observed. In the validation study, high detection rate of 56.4% was obtained. None of the control samples tested positive, i.e., false-positive results were absent. Conclusions The Seeplex Meningitis ACE Detection kit showed high sensitivity, specificity, and detection rate for the identification of pathogens in clinical CSF samples. This kit may be useful for rapid identification of important acute meningitis-causing pathogens. PMID:22259778

  16. Detection of Cytomegalovirus (CMV) DNA in EDTA Whole-Blood Samples: Evaluation of the Quantitative artus CMV LightCycler PCR Kit in Conjunction with Automated Sample Preparation▿

    PubMed Central

    Michelin, Birgit D. A.; Hadžisejdić, Ita; Bozic, Michael; Grahovac, Maja; Hess, Markus; Grahovac, Blaženka; Marth, Egon; Kessler, Harald H.

    2008-01-01

    Whole blood has been found to be a reliable matrix for the detection and quantitation of cytomegalovirus (CMV) DNA. In this study, the performance of the artus CMV LightCycler (LC) PCR kit in conjunction with automated sample preparation on a BioRobot EZ1 workstation was evaluated. The accuracy, linearity, analytical sensitivity, and inter- and intra-assay variations were determined. A total of 102 clinical EDTA whole-blood samples were investigated, and results were compared with those obtained with the in vitro diagnostics (IVD)/Conformité Européene (CE)-labeled CMV HHV6,7,8 R-gene quantification kit. When the accuracy of the new kit was tested, seven of eight results were found to be within ±0.5 log10 unit of the expected panel results. Determination of linearity resulted in a quasilinear curve over more than 5 log units. The lower limit of detection of the assay was determined to be 139 copies/ml in EDTA whole blood. The interassay variation ranged from 15 to 58%, and the intra-assay variation ranged from 7 to 35%. When clinical samples were tested and the results were compared with those of the routinely used IVD/CE-labeled assay, 53 samples tested positive and 13 samples tested negative by both of the assays. One sample was found to be positive with the artus CMV LC PCR kit only, and 35 samples tested positive with the routinely used assay only. The majority of discrepant results were found with low-titer samples. In conclusion, use of the artus CMV LC PCR kit in conjunction with automated sample preparation on the BioRobot EZ1 workstation may be suitable for the detection and quantitation of CMV DNA in EDTA whole blood in the routine low-throughput laboratory; however, low-positive results may be missed by this assay. PMID:18272703

  17. Detection of cytomegalovirus (CMV) DNA in EDTA whole-blood samples: evaluation of the quantitative artus CMV LightCycler PCR kit in conjunction with automated sample preparation.

    PubMed

    Michelin, Birgit D A; Hadzisejdic, Ita; Bozic, Michael; Grahovac, Maja; Hess, Markus; Grahovac, Blazenka; Marth, Egon; Kessler, Harald H

    2008-04-01

    Whole blood has been found to be a reliable matrix for the detection and quantitation of cytomegalovirus (CMV) DNA. In this study, the performance of the artus CMV LightCycler (LC) PCR kit in conjunction with automated sample preparation on a BioRobot EZ1 workstation was evaluated. The accuracy, linearity, analytical sensitivity, and inter- and intra-assay variations were determined. A total of 102 clinical EDTA whole-blood samples were investigated, and results were compared with those obtained with the in vitro diagnostics (IVD)/Conformité Européene (CE)-labeled CMV HHV6,7,8 R-gene quantification kit. When the accuracy of the new kit was tested, seven of eight results were found to be within +/-0.5 log(10) unit of the expected panel results. Determination of linearity resulted in a quasilinear curve over more than 5 log units. The lower limit of detection of the assay was determined to be 139 copies/ml in EDTA whole blood. The interassay variation ranged from 15 to 58%, and the intra-assay variation ranged from 7 to 35%. When clinical samples were tested and the results were compared with those of the routinely used IVD/CE-labeled assay, 53 samples tested positive and 13 samples tested negative by both of the assays. One sample was found to be positive with the artus CMV LC PCR kit only, and 35 samples tested positive with the routinely used assay only. The majority of discrepant results were found with low-titer samples. In conclusion, use of the artus CMV LC PCR kit in conjunction with automated sample preparation on the BioRobot EZ1 workstation may be suitable for the detection and quantitation of CMV DNA in EDTA whole blood in the routine low-throughput laboratory; however, low-positive results may be missed by this assay.

  18. Can we use postal surveys with anonymous testing to monitor chlamydia prevalence in young women in England? Pilot study incorporating randomised controlled trial of recruitment methods.

    PubMed

    Woodhall, Sarah C; Nichols, Tom; Alexander, Sarah; da Silva, Filomeno Coelho; Mercer, Catherine H; Ison, Catherine; Gill, O Noel; Soldan, Kate

    2015-09-01

    Chlamydia prevalence in the general population is a potential outcome measure for the evaluation of chlamydia control programmes. We carried out a pilot study to determine the feasibility of using a postal survey for population-based chlamydia prevalence monitoring. Postal invitations were sent to a random sample of 2000 17-year-old to 18-year-old women registered with a general practitioner in two pilot areas in England. Recipients were randomised to receive either a self-sampling kit (n=1000), a self-sampling kit and offer of £5 voucher on return of sample (n=500) or a self-sampling kit on request (n=500). Participants returned a questionnaire and self-taken vulvovaginal swab sample for unlinked anonymous Chlamydia trachomatis testing. Non-responders were sent a reminder letter 3 weeks after initial invitation. We calculated the participation rate (number of samples returned/number of invitations sent) and cost per sample returned (including cost of consumables and postage) in each group. A total of 155/2000 (7.8%) samples were returned with consent for testing. Participation rates varied by invitation group: 7.8% in the group who were provided with a self-sampling kit, 14% in the group who were also offered a voucher and 1.0% in the group who were not sent a kit. The cost per sample received was lowest (£36) in the group who were offered both a kit and a voucher. The piloted survey methodology achieved low participation rates. This approach is not suitable for population-based monitoring of chlamydia prevalence among young women in England. (UKCRN ID 10913). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Internal validation of the GlobalFiler™ Express PCR Amplification Kit for the direct amplification of reference DNA samples on a high-throughput automated workflow.

    PubMed

    Flores, Shahida; Sun, Jie; King, Jonathan; Budowle, Bruce

    2014-05-01

    The GlobalFiler™ Express PCR Amplification Kit uses 6-dye fluorescent chemistry to enable multiplexing of 21 autosomal STRs, 1 Y-STR, 1 Y-indel and the sex-determining marker amelogenin. The kit is specifically designed for processing reference DNA samples in a high throughput manner. Validation studies were conducted to assess the performance and define the limitations of this direct amplification kit for typing blood and buccal reference DNA samples on various punchable collection media. Studies included thermal cycling sensitivity, reproducibility, precision, sensitivity of detection, minimum detection threshold, system contamination, stochastic threshold and concordance. Results showed that optimal amplification and injection parameters for a 1.2mm punch from blood and buccal samples were 27 and 28 cycles, respectively, combined with a 12s injection on an ABI 3500xL Genetic Analyzer. Minimum detection thresholds were set at 100 and 120RFUs for 27 and 28 cycles, respectively, and it was suggested that data from positive amplification controls provided a better threshold representation. Stochastic thresholds were set at 250 and 400RFUs for 27 and 28 cycles, respectively, as stochastic effects increased with cycle number. The minimum amount of input DNA resulting in a full profile was 0.5ng, however, the optimum range determined was 2.5-10ng. Profile quality from the GlobalFiler™ Express Kit and the previously validated AmpFlSTR(®) Identifiler(®) Direct Kit was comparable. The validation data support that reliable DNA typing results from reference DNA samples can be obtained using the GlobalFiler™ Express PCR Amplification Kit. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. Developmental Validation of Short Tandem Repeat Reagent Kit for Forensic DNA Profiling of Canine Biological Materials

    PubMed Central

    Dayton, Melody; Koskinen, Mikko T; Tom, Bradley K; Mattila, Anna-Maria; Johnston, Eric; Halverson, Joy; Fantin, Dennis; DeNise, Sue; Budowle, Bruce; Smith, David Glenn; Kanthaswamy, Sree

    2009-01-01

    Aim To develop a reagent kit that enables multiplex polymerase chain reaction (PCR) amplification of 18 short tandem repeats (STR) and the canine sex-determining Zinc Finger marker. Methods Validation studies to determine the robustness and reliability in forensic DNA typing of this multiplex assay included sensitivity testing, reproducibility studies, intra- and inter-locus color balance studies, annealing temperature and cycle number studies, peak height ratio determination, characterization of artifacts such as stutter percentages and dye blobs, mixture analyses, species-specificity, case type samples analyses and population studies. Results The kit robustly amplified domesticated dog samples and consistently generated full 19-locus profiles from as little as 125 pg of dog DNA. In addition, wolf DNA samples could be analyzed with the kit. Conclusion The kit, which produces robust, reliable, and reproducible results, will be made available for the forensic research community after modifications based on this study’s evaluation to comply with the quality standards expected for forensic casework. PMID:19480022

  1. A First Application of Enzyme-Linked Immunosorbent Assay for Screening Cyclodiene Insecticides in Ground Water

    USGS Publications Warehouse

    Dombrowski, T.R.; Thurman, E.M.; Mohrman, G.B.

    1996-01-01

    A commercially available enzyme-linked immunosorbent assay (ELISA) plate kit for screening of cyclodiene insecticides (aldrin, chlordane, dieldrin, endosulfan, endrin, and heptachlor) was evaluated for sensitivity, cross reactivity, and overall performance using groundwater samples from a contaminated site. Ground-water contaminants included several pesticide compounds and their manufacturing byproducts, as well as many other organic and inorganic compounds. Cross-reactivity studies were carried out for the cyclodiene compounds, and results were compared to those listed by the manufacturer. Data obtained were used to evaluate the sensitivity of the ELISA kit to the cyclodiene compounds in ground water samples with a contaminated matrix. The method quantitation limit for the ELISA kit was 15 ??g/L (as chlordane). Of the 56 ground-water samples analyzed using the ELISA plate kits, more than 85% showed cyclodiene insecticide contamination. The ELISA kit showed excellent potential as a screening tool for sites with suspected groundwater contamination by insecticides.

  2. DNA extraction and barcode identification of development stages of forensically important flies in the Czech Republic.

    PubMed

    Olekšáková, Tereza; Žurovcová, Martina; Klimešová, Vanda; Barták, Miroslav; Šuláková, Hana

    2018-04-01

    Several methods of DNA extraction, coupled with 'DNA barcoding' species identification, were compared using specimens from early developmental stages of forensically important flies from the Calliphoridae and Sarcophagidae families. DNA was extracted at three immature stages - eggs, the first instar larvae, and empty pupal cases (puparia) - using four different extraction methods, namely, one simple 'homemade' extraction buffer protocol and three commercial kits. The extraction conditions, including the amount of proteinase K and incubation times, were optimized. The simple extraction buffer method was successful for half of the eggs and for the first instar larval samples. The DNA Lego Kit and DEP-25 DNA Extraction Kit were useful for DNA extractions from the first instar larvae samples, and the DNA Lego Kit was also successful regarding the extraction from eggs. The QIAamp DNA mini kit was the most effective; the extraction was successful with regard to all sample types - eggs, larvae, and pupari.

  3. Total 25-Hydroxyvitamin D Determination by an Entry Level Triple Quadrupole Instrument: Comparison between Two Commercial Kits

    PubMed Central

    Cocci, Andrea; Zuppi, Cecilia; Persichilli, Silvia

    2013-01-01

    Objective. 25-hydroxyvitamin D2/D3 (25-OHD2/D3) determination is a reliable biomarker for vitamin D status. Liquid chromatography-tandem mass spectrometry was recently proposed as a reference method for vitamin D status evaluation. The aim of this work is to compare two commercial kits (Chromsystems and PerkinElmer) for 25-OHD2/D3 determination by our entry level LC-MS/MS. Design and Methods. Chromsystems kit adds an online trap column to an HPLC column and provides atmospheric pressure chemical ionization, isotopically labeled internal standard, and 4 calibrator points. PerkinElmer kit uses a solvent extraction and protein precipitation method. This kit can be used with or without derivatization with, respectively, electrospray and atmospheric pressure chemical ionization. For each analyte, there are isotopically labeled internal standards and 7 deuterated calibrator points. Results. Performance characteristics are acceptable for both methods. Mean bias between methods calculated on 70 samples was 1.9 ng/mL. Linear regression analysis gave an R 2 of 0.94. 25-OHD2 is detectable only with PerkinElmer kit in derivatized assay option. Conclusion. Both methods are suitable for routine. Chromsystems kit minimizes manual sample preparation, requiring only protein precipitation, but, with our system, 25-OHD2 is not detectable. PerkinElmer kit without derivatization does not guarantee acceptable performance with our LC-MS/MS system, as sample is not purified online. Derivatization provides sufficient sensitivity for 25-OHD2 detection. PMID:23555079

  4. Evaluation of a newly developed quantitative determination kit for tumor marker CA15-3 with chemiluminescent assay.

    PubMed

    Li, Peihua; Ye, Huiming; Liu, Jiangwu; Jin, Hongwei; Lin, Yongzhi; Yan, Shuidi; Yu, Yang; Gao, Lei; Xu, Feihai; Zhang, Zhongying

    2018-01-01

    Tumor marker carbohydrate antigen 15-3 (CA15-3) is used as a biomarker to aid to diagnose and monitor the prognosis of breast cancer patients. A new quantitative determination kit for CA15-3 with chemiluminescent assay was developed by Xiamen InnoDx Biotech Co., Ltd, China. Therefore, we conducted the report to evaluate the performance of the kit. According to the "Guiding principles on performance analysis of diagnostic reagents in vitro", the calibration curve, limit of detection, reportable range, accuracy, precision, anti-interference capability, cross-reaction and comparison by measuring EDTA plasma and serum were carried out. In addition, the kit was performed in parallel to electrochemiluminescence immunoassay kit (Roche) to analyze the correlation between the two kits. Regression equation of calibration curve of the kit was Y=0.7914X+4.1032 (R 2 =.990). Limit of detection was 0.0347 U/mL. The reportable range was 0.5-2400 U/mL. Recovery ratio was 100.0%-104.8%. Coefficient of variations (CVs) of within-run and between-run were 4.8%-7.6% and 5.8%-7.4% respectively. No remarkable interferences (all Bias% were less than ±10%) were detected when samples contained hemoglobin ≤183.8 μmol/L, bilirubin ≤340 μmol/L, triglyceride ≤18.1 mmol/L, or rheumatoid factor ≤400 U/mL. No cross-reaction was present in the kit. Moreover, compared with the results from electrochemiluminescence immunoassay kit (Roche) in 345 serum samples, there was a satisfied correlation coefficient of 0.977 (P<.01), and the kit was simultaneously fit for the detection of EDTA plasma and serum samples. The new kit validated satisfactorily, and it can be used for detecting CA15-3 in clinical practice. © 2017 The Authors Journal of Clinical Laboratory Analysis Published by Wiley Periodicals, Inc.

  5. Repeatability and validity of a field kit for estimation of cholinesterase in whole blood.

    PubMed Central

    London, L; Thompson, M L; Sacks, S; Fuller, B; Bachmann, O M; Myers, J E

    1995-01-01

    OBJECTIVES--To evaluate a spectrophotometric field kit (Test-Mate-OP) for repeatability and validity in comparison with reference laboratory methods and to model its anticipated sensitivity and specificity based on these findings. METHODS--76 farm workers between the age of 20 and 55, of whom 30 were pesticide applicators exposed to a range of organophosphates in the preceding 10 days, had blood taken for plasma cholinesterase (PCE) and erythrocyte cholinesterase (ECE) measurement by field kit or laboratory methods. Paired blinded duplicate samples were taken from subgroups in the sample to assess repeatability of laboratory and field kit methods. Field kits were also used to test venous blood in one subgroup. The variance obtained for the field kit tests was then applied to two hypothetical scenarios that used published action guidelines to model the kit's sensitivity and specificity. RESULTS--Repeatability for PCE was much poorer and for ECE slightly poorer than that of laboratory measures. A substantial upward bias for field kit ECE relative to laboratory measurements was found. Sensitivity of the kit to a 40% drop in PCE was 67%, whereas that for ECE was 89%. Specificity of the kit with no change in mean of the population was 100% for ECE and 91% for PCE. CONCLUSION--Field kit ECE estimation seems to be sufficiently repeatable for surveillance activities, whereas PCE does not. Repeatability of both tests seems to be too low for use in epidemiological dose-response investigations. Further research is indicated to characterise the upward bias in ECE estimation on the kit. PMID:7697143

  6. Establishing a novel automated magnetic bead-based method for the extraction of DNA from a variety of forensic samples.

    PubMed

    Witt, Sebastian; Neumann, Jan; Zierdt, Holger; Gébel, Gabriella; Röscheisen, Christiane

    2012-09-01

    Automated systems have been increasingly utilized for DNA extraction by many forensic laboratories to handle growing numbers of forensic casework samples while minimizing the risk of human errors and assuring high reproducibility. The step towards automation however is not easy: The automated extraction method has to be very versatile to reliably prepare high yields of pure genomic DNA from a broad variety of sample types on different carrier materials. To prevent possible cross-contamination of samples or the loss of DNA, the components of the kit have to be designed in a way that allows for the automated handling of the samples with no manual intervention necessary. DNA extraction using paramagnetic particles coated with a DNA-binding surface is predestined for an automated approach. For this study, we tested different DNA extraction kits using DNA-binding paramagnetic particles with regard to DNA yield and handling by a Freedom EVO(®)150 extraction robot (Tecan) equipped with a Te-MagS magnetic separator. Among others, the extraction kits tested were the ChargeSwitch(®)Forensic DNA Purification Kit (Invitrogen), the PrepFiler™Automated Forensic DNA Extraction Kit (Applied Biosystems) and NucleoMag™96 Trace (Macherey-Nagel). After an extensive test phase, we established a novel magnetic bead extraction method based upon the NucleoMag™ extraction kit (Macherey-Nagel). The new method is readily automatable and produces high yields of DNA from different sample types (blood, saliva, sperm, contact stains) on various substrates (filter paper, swabs, cigarette butts) with no evidence of a loss of magnetic beads or sample cross-contamination. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  7. Evaluation of the PrioCHECK™ Trichinella AAD Kit for the digestion and recovery of larvae in pork, horse meat and wild meat.

    PubMed

    Konecsni, Kelly; Scheller, Cheryl; Scandrett, Brad; Buholzer, Patrik; Gajadhar, Alvin

    2017-08-30

    The artificial digestion magnetic stirrer method using pepsin protease and hydrochloric acid is the standard assay for the detection of Trichinella larvae in muscle of infected animals. Recently, an alternative enzyme, serine protease, was employed in the development of a commercially available digestion kit (PrioCHECK™ Trichinella AAD Kit). This assay requires a higher digestion temperature of 60°C which kills the larvae during the digestion process, mitigating the risk of environmental contamination from the parasite. The present study was conducted to determine the performance of the PrioCHECK™ Trichinella AAD Kit compared to the conventional pepsin/HCl digestion. Replicate paired 115g samples of Trichinella-negative pork diaphragm and masseter, and of horse tongue and masseter, were used to compare the two methods for tissue digestibility. Similarly, paired 100g samples of pork diaphragm and horse tongue were spiked with proficiency samples containing known numbers of Trichinella spiralis first stage larvae to compare larval recoveries for the two methods. Masseter samples from wild bears and wolves naturally infected with Trichinella nativa or T6 were also used to compare the performance of the methods. The results of the study showed that the PrioCHECK™ Trichinella AAD Kit, when used according to the manufacturer's instructions, was effective in detecting Trichinella infection in all samples that contained 0.05 or more larvae per gram of tissue. Although there was no significant difference between the Kit method and the standard pepsin/HCl digestion procedure in the average number of larvae recovered from spiked pork diaphragm, 38% fewer larvae were recovered from similarly spiked samples of horse tongue by digestion using serine protease (one way ANOVA, P value <0.001). Additional clarification was also more often required for both horse meat and pork when using the Kit compared to the pepsin/HCl method. The results of testing wildlife samples were similar for the two methods. Overall, the performance of the Kit method was suitable for the digestion of muscle samples and recovery of Trichinella larvae, according to international standards. It also provides advantages of faster digestion, safer reagents and recovered parasites that are non-hazardous for analysts and the environment. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  8. Sample rotating turntable kit for infrared spectrometers

    DOEpatents

    Eckels, Joel Del [Livermore, CA; Klunder, Gregory L [Oakland, CA

    2008-03-04

    An infrared spectrometer sample rotating turntable kit has a rotatable sample cup containing the sample. The infrared spectrometer has an infrared spectrometer probe for analyzing the sample and the rotatable sample cup is adapted to receive the infrared spectrometer probe. A reflectance standard is located in the rotatable sample cup. A sleeve is positioned proximate the sample cup and adapted to receive the probe. A rotator rotates the rotatable sample cup. A battery is connected to the rotator.

  9. Mutation scanning of BRAF, NRAS, KIT, and GNAQ/GNA11 in oral mucosal melanoma: a study of 57 cases.

    PubMed

    Lyu, Jiong; Wu, Yunteng; Li, Chaojun; Wang, Runxiang; Song, Hao; Ren, Guoxin; Guo, Wei

    2016-04-01

    Recent advances in novel targeted therapies have created the need for molecular characterization of cancer to allow accurate personalized treatments. In this study, our aim was to investigate the incidence of activating mutations of oncogenes BRAF, NRAS, KIT, and GNAQ/GNA11 in oral mucosal melanoma. We analyzed a cohort of 57 oral mucosal melanoma samples, including 27 frozen samples and 30 formalin-fixed paraffin-embedded samples. The tumors were screened for hotspot mutations of BRAF (exon 15), NRAS (exons 2 and 3), KIT (exons 9, 11, 13, and 17), and GNAQ/GNA11 (exon 5) by high-resolution melting and direct sequencing. In oral mucosal melanoma, 7.0% of tumors harbored KIT mutations and 3.5% harbored BRAF mutations, while classic BRAF V600E mutation was not detected. We found no mutations of NRAS or GNAQ/GNA11 in oral mucosal melanoma. We demonstrated that driver mutations are rare in mutational hotspots of BRAF, NRAS, KIT, and GNAQ/GNA11 in oral mucosal melanoma. The majority of patients will not benefit from KIT and BRAF inhibitors. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Evaluation of Scat Deposition Transects versus Radio Telemetry for Developing a Species Distribution Model for a Rare Desert Carnivore, the Kit Fox.

    PubMed

    Dempsey, Steven J; Gese, Eric M; Kluever, Bryan M; Lonsinger, Robert C; Waits, Lisette P

    2015-01-01

    Development and evaluation of noninvasive methods for monitoring species distribution and abundance is a growing area of ecological research. While noninvasive methods have the advantage of reduced risk of negative factors associated with capture, comparisons to methods using more traditional invasive sampling is lacking. Historically kit foxes (Vulpes macrotis) occupied the desert and semi-arid regions of southwestern North America. Once the most abundant carnivore in the Great Basin Desert of Utah, the species is now considered rare. In recent decades, attempts have been made to model the environmental variables influencing kit fox distribution. Using noninvasive scat deposition surveys for determination of kit fox presence, we modeled resource selection functions to predict kit fox distribution using three popular techniques (Maxent, fixed-effects, and mixed-effects generalized linear models) and compared these with similar models developed from invasive sampling (telemetry locations from radio-collared foxes). Resource selection functions were developed using a combination of landscape variables including elevation, slope, aspect, vegetation height, and soil type. All models were tested against subsequent scat collections as a method of model validation. We demonstrate the importance of comparing multiple model types for development of resource selection functions used to predict a species distribution, and evaluating the importance of environmental variables on species distribution. All models we examined showed a large effect of elevation on kit fox presence, followed by slope and vegetation height. However, the invasive sampling method (i.e., radio-telemetry) appeared to be better at determining resource selection, and therefore may be more robust in predicting kit fox distribution. In contrast, the distribution maps created from the noninvasive sampling (i.e., scat transects) were significantly different than the invasive method, thus scat transects may be appropriate when used in an occupancy framework to predict species distribution. We concluded that while scat deposition transects may be useful for monitoring kit fox abundance and possibly occupancy, they do not appear to be appropriate for determining resource selection. On our study area, scat transects were biased to roadways, while data collected using radio-telemetry was dictated by movements of the kit foxes themselves. We recommend that future studies applying noninvasive scat sampling should consider a more robust random sampling design across the landscape (e.g., random transects or more complete road coverage) that would then provide a more accurate and unbiased depiction of resource selection useful to predict kit fox distribution.

  11. A cost effective hydrogel test kit for pre and post blast trinitrotoluene.

    PubMed

    Choodum, Aree; Malathong, Khanitta; NicDaeid, Niamh; Limsakul, Wadcharawadee; Wongniramaikul, Worawit

    2016-09-01

    A cost effective hydrogel test kit was successfully developed for the detection of pre- and post-blast trinitrotoluene (TNT). A polyvinyl alcohol (PVA) hydrogel matrix was used to entrap the potassium hydroxide (KOH) colourimetric reagent. The easily portable test kit was fabricated in situ in a small tube to which the sample could be added directly. The test kit was used in conjunction with digital image colourimetry (DIC) to demonstrate the rapid quantitative analysis of TNT in a test soil sample. The built-in digital camera of an iPhone was used to capture digital images of the colourimetric products from the test kit. Red-Green-Blue (RGB) colour data from the digital images of TNT standard solutions were used to establish a calibration graph. The validation of the DIC method indicated excellent inter day precision (0.12-3.60%RSD) and accuracy (93-108% relative accuracy). Post-blast soil samples containing TNT were analysed using the test kit and were in good agreement with spectrophotometric analysis. The intensity of the RGB data from the TNT complex deviated by +6.3%, +5.1%, and -4.9% after storage of the test kits in a freezer for 3 months. The test kit was also reusable for up to 12 times with only -5.4%, +0.3%, and +4.0% deviations. The hydrogel test kit was applied in the detection of trace explosive residues at the scene of the recent Bangkok bombing at the Ratchaprasong intersection and produced positive results for TNT demonstrating its operational field application as a rapid and cost effective quantitative tool for explosive residue analysis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Comparison of the sensitivity of the Legionella urinary antigen EIA kits from Binax and Biotest with urine from patients with infections caused by less common serogroups and subgroups of Legionella.

    PubMed

    Olsen, C W; Elverdal, P; Jørgensen, C S; Uldum, S A

    2009-07-01

    The detection of urinary antigen is the most widely used method to diagnose Legionnaires' disease (LD), so it is important that these assays have a high sensitivity for the disease. In this study, we compare two kits for their ability to detect urinary antigen in urine samples from patients infected with Legionella species and L. pneumophila sero- and subgroups not considered as the most common causes of LD. Urine samples (n = 33) from 30 culture-proven cases of L. pneumophila serogroup (sg) 1, subgroup non-Pontiac infection, and urine samples (n = 35) from 32 cases of non-L. pneumophila species or non-sg 1 infection were examined using the Binax EIA and Biotest EIA kits. For both groups, the overall diagnostic sensitivity of the Binax kit was significantly better than the sensitivity of the Biotest kits (P < 0.0001). For the non-Pontiac group, the sensitivity was 81.8 and 42.4%, respectively, and for the non-sg1 group, it was 51.4 and 28.6%, respectively. It was concluded that the Binax kit was more suitable for the general diagnosis of LD than the Biotest kit, but we still need urinary antigen detection methods with higher sensitivity for non-sg1 LD.

  13. Development and evaluation of the RT-PCR kit for the rabies virus diagnosis.

    PubMed

    Dedkov, Vladimir G; Deviatkin, A A; Poleschuk, E M; Safonova, M V; Markelov, M L; Shipulin, G A

    To improve the diagnosis, surveillance, and control for the rabies virus, a kit for hybridization-triggered fluorescence detection of rabies virus DNA by the RT-PCR technique was developed and evaluated. The analytical sensitivity of the kit was 4*10 GE per ml. High specificity of the kit was shown using representative sampling of viral, bacterial, and human nucleic acids.

  14. [The Quality Analysis of National Supervising Sampling for Rubella Virus IgM Diagnostic Kits in 2014].

    PubMed

    Yu, Tina; Qu, Shoufang; Zhang, Xiaoyan; Sun, Nan; Gao, Shangxian; Li, Haining; Huang, Jie

    2015-07-01

    To evaluate the quality status of rubella virus IgM diagnostic kits by national supervising sampling. Using legal inspection combining with exploratory study, the positive and negative coincidence rate, detection limit and repeatability of kits were verified. The results showed that 15 of 16 batches of kits were qualified using legal inspection, and the passing rate was 93.8%. The unqualified item was negative coincidence rate. In exploratory study, only 11 batches (68.8%) complied with industry standard. The unqualified items were negative coincidence rate, detection limit and repeatability. At present, rubella virus IgM diagnostic Kits have some quality problems in the market. It is recommended that we adopt industry standard and national reference panel in the registration inspection for the future, which will prompt enterprises to improve quality.

  15. Evaluation of Cariogenic Bacteria

    PubMed Central

    Nishikawara, Fusao; Nomura, Yoshiaki; Imai, Susumu; Senda, Akira; Hanada, Nobuhiro

    2007-01-01

    Objectives The evaluation of Mutans streptococci (MS) is one of the index for caries risk. DentocultTM and CRTTM are commercial kits to detect and evaluate MS, conveniently. However, the evaluation of MS has also been carried out simply using an instruction manual. But the instruction manual is not easy to use for evaluation of MS. The aim of this study was to examine the utility of modified Mitis-Salivalius Bacitracin (MSB) agar medium compared with MSB agar medium and commercial kits, and to establish a convenient kit (mMSB-kit) using modified MSB agar. Methods The MS in stimulated saliva from 27 subjects were detected by MSB, modified MSB agar medium and commercial kits. Laboratory and clinically isolated strains of MS were similarly evaluated. The ratios of MS in detected bacteria were compared by ELISA. Results The scores using an mMSB-kit on the basis of modified MSB agar medium were tabulated. Saliva samples showed different levels of MS between culture methods and the commercial kit. Some samples which were full of MS were not detected by the commercial kit. The detection of MS by modified MSB agar medium and mMSB-kit were significantly higher when compared with MSB agar medium,CRTTM, (P< .01) and Dentocult SMTM (P<.05). Conclusion The sensitivity for detection of MS is higher for modified MSB agar medium when compared with MSB agar medium. The mMSB-kit can be used simply, and can be an important contributor for the evaluation of MS as a caries risk factor. PMID:19212495

  16. Immunomagnetic Separation of Cryptosporidium parvum from Source Water Samples of Various Turbidities

    PubMed Central

    Bukhari, Z.; McCuin, R. M.; Fricker, C. R.; Clancy, J. L.

    1998-01-01

    Immunomagnetic separation (IMS) procedures which specifically capture Cryptosporidium oocysts and have the potential to isolate oocysts from debris have become commercially available. We compared two IMS kits (kit DB [Dynabeads anti-Cryptosporidium; product no. 730.01; Dynal A.S., Oslo, Norway] and kit IC1 [Crypto Scan IMS; product no. R10; Clearwater Diagnostics Company, LLC, Portland, Maine]) and a modification of kit IC1 (kit IC2 [Crypto Scan IMS; product no. R10; Clearwater Diagnostics Company, LLC]) at three turbidity levels (50, 500, and 5,000 nephelometric turbidity units [ntu]) by using water matrices obtained from different geographical locations. In deionized water, kit DB yielded recoveries between 68 and 83%, whereas the recoveries obtained with kits IC1 and IC2 were more variable and ranged from 0.2 to 74.5%. In water matrices with turbidity levels up to 500 ntu, the oocyst recoveries were more variable with kit DB; however, the recoveries were similar to those obtained in deionized water. In contrast, there were notable reductions in oocyst recoveries in the turbid matrices with kits IC1 and IC2, and the highest recovery (8.3%) was obtained with a 50-ntu sample. An examination of the effects of age on oocyst recovery with kit DB revealed that oocysts up to 16 weeks old yielded recoveries similar to the recoveries observed with fresh oocysts. These data indicate that all IMS kits do not perform equally well, and it is important to conduct in-house quality assurance work before a commercially available IMS kit is selected to replace flotation procedures for recovery of Cryptosporidium oocysts. PMID:9797313

  17. Coxiellosis in domestic livestock of Puducherry and Tamil Nadu: Detection of Coxiella burnetii DNA by polymerase chain reaction in slaughtered ruminants

    PubMed Central

    Pradeep, Jothimani; Stephen, Selvaraj; Pooja, Pratheesh; Akshayavardhini, Anbalagan; Sangeetha, Balakrishnan; Antony, Prabakar Xavier

    2017-01-01

    Background and Aim:: In the course of our Indian Council of Medical Research project on coxiellosis in Puducherry and Tamil Nadu, 5.64% goat, 1.85% sheep, 1.06% buffaloes, and 0.97% cattle were positive for Coxiella burnetii antibodies by enzyme linked immunosorbent assay kit (IDEXX, Liebefeld, Switzerland). In this preliminary study, we have proceeded to look for C. burnetii DNA in those antibody positive specimens employing an imported commercial C. burnetii polymerase chain reaction (PCR) kit. Materials and Methods:: Blood samples were collected during slaughtering. All 15 blood samples of antibody positive ruminants and three antibody negative samples were subjected to conventional Trans-PCR assay with a commercial PCR kit (Genekam Biotechnology AG, Duisburg, Germany). An in-house Trans-PCR was included in the study for comparison. Results:: A total of 15 antibody positive and three antibody-negative serum samples belonging to 11 goat, 4 sheep, 1 cattle, and 2 buffaloes were tested in duplicate for the presence of C. burnetii DNA by the commercial agar gel PCR kit and an in-house Trans-PCR. Only one buffalo serum sample was positive for C. burnetii with a band at 243 bp in in-house Trans-PCR. Discussion:: Seropositivity for C. burnetii need not necessarily translate into infectivity status of the animal. Conversely, seronegative ruminants can shed C. burnetii. Rapid disintegration of C. burnetii DNA during the storage period is an important impediment in QF-PCR research. This is the first time the performance of this commercial PCR kit is being validated in India. Conclusion:: Commercial PCR kit, Genekam did not identify any positive sample, probably because it targeted a larger amplicon of 687 bp. PMID:28717320

  18. Board Policies on Student Records. Educational Policies Development Kit.

    ERIC Educational Resources Information Center

    National School Boards Association, Waterford, CT. Educational Policies Service.

    This report of policy samples is the 17th in a continuing series of kit-booklets issued to help school boards develop written policies in key subject areas. The intent in providing samples is to encourage thinking in policy terms; and to provide working papers to be edited, modified, or adapted to meet local requirements. Policy samples herein…

  19. A framework for measurement and harmonization of pediatric multiple sclerosis etiologic research studies: The Pediatric MS Tool-Kit.

    PubMed

    Magalhaes, Sandra; Banwell, Brenda; Bar-Or, Amit; Fortier, Isabel; Hanwell, Heather E; Lim, Ming; Matt, Georg E; Neuteboom, Rinze F; O'Riordan, David L; Schneider, Paul K; Pugliatti, Maura; Shatenstein, Bryna; Tansey, Catherine M; Wassmer, Evangeline; Wolfson, Christina

    2018-06-01

    While studying the etiology of multiple sclerosis (MS) in children has several methodological advantages over studying etiology in adults, studies are limited by small sample sizes. Using a rigorous methodological process, we developed the Pediatric MS Tool-Kit, a measurement framework that includes a minimal set of core variables to assess etiological risk factors. We solicited input from the International Pediatric MS Study Group to select three risk factors: environmental tobacco smoke (ETS) exposure, sun exposure, and vitamin D intake. To develop the Tool-Kit, we used a Delphi study involving a working group of epidemiologists, neurologists, and content experts from North America and Europe. The Tool-Kit includes six core variables to measure ETS, six to measure sun exposure, and six to measure vitamin D intake. The Tool-Kit can be accessed online ( www.maelstrom-research.org/mica/network/tool-kit ). The goals of the Tool-Kit are to enhance exposure measurement in newly designed pediatric MS studies and comparability of results across studies, and in the longer term to facilitate harmonization of studies, a methodological approach that can be used to circumvent issues of small sample sizes. We believe the Tool-Kit will prove to be a valuable resource to guide pediatric MS researchers in developing study-specific questionnaire.

  20. Advantage of using a home-made ELISA kit for detection of Helicobacter pylori infection over commercially imported kits.

    PubMed

    Mohammadi, M; Talebkhan, Y; Khalili, G; Mahboudi, F; Massarrat, S; Zamaninia, L; Oghalaei, A

    2008-01-01

    To evaluate a home-made ELISA kit for detection of Helicobacter pylori (Hp) infection and comparison of its immunologic criteria with those of foreign commercial kits. A home-made IgG ELISA kit was developed using soluble antigenic fractions of Hp proteins. Confirmed sera were tested and serological criteria were evaluated through assessment of 199 serum samples. The accuracy, sensitivity and specificity values of home-made kit were 92, 92 and 90.4%, respectively. These immunologic criteria for Trinity kit were 95.2, 95.2 and 95% in comparison with IBL kit (91.3, 92.2 and 88.5%), BIOHIT kit (72.4, 41.6 and 94.1%) and HelicoBlot2.1 (94.2, 93.4 and 100%). Kappa agreement assessment demonstrated that two of the imported ELISA kits had fair to moderate agreement with the home-made kit while the other one had a poor agreement value. Apart from comparable values between the home-made kit and the most efficient imported kit (Trinity) there was significant cost benefit. Therefore, we recommend the home-made kit as a suitable substitution for detection of Hp infection in the Iranian population.

  1. Arsenic exposure in drinking water: an unrecognized health threat in Peru.

    PubMed

    George, Christine Marie; Sima, Laura; Arias, M Helena Jahuira; Mihalic, Jana; Cabrera, Lilia Z; Danz, David; Checkley, William; Gilman, Robert H

    2014-08-01

    To assess the extent of arsenic contamination of groundwater and surface water in Peru and, to evaluate the accuracy of the Arsenic Econo-Quick(™) (EQ) kit for measuring water arsenic concentrations in the field. Water samples were collected from 151 water sources in 12 districts of Peru, and arsenic concentrations were measured in the laboratory using inductively-coupled plasma mass spectrometry. The EQ field kit was validated by comparing a subset of 139 water samples analysed by laboratory measurements and the EQ kit. In 86% (96/111) of the groundwater samples, arsenic exceeded the 10 µg/l arsenic concentration guideline given by the World Health Organization (WHO) for drinking water. In 56% (62/111) of the samples, it exceeded the Bangladeshi threshold of 50 µg/l; the mean concentration being 54.5 µg/l (range: 0.1-93.1). In the Juliaca and Caracoto districts, in 96% (27/28) of groundwater samples arsenic was above the WHO guideline; and in water samples collected from the section of the Rímac river running through Lima, all had arsenic concentrations exceeding the WHO limit. When validated against laboratory values, the EQ kit correctly identified arsenic contamination relative to the guideline in 95% (106/111) of groundwater and in 68% (19/28) of surface water samples. In several districts of Peru, drinking water shows widespread arsenic contamination, exceeding the WHO arsenic guideline. This poses a public health threat requiring further investigation and action. For groundwater samples, the EQ kit performed well relative to the WHO arsenic limit and therefore could provide a vital tool for water arsenic surveillance.

  2. Determining Indirect Cost Rates in Research Libraries. SPEC Kit 34.

    ERIC Educational Resources Information Center

    Association of Research Libraries, Washington, DC. Office of Management Studies.

    This kit prepared by the Association of Research Libraries (ARL) contains 15 primary source documents on determining indirect cost rates in research libraries. The kit comprises: (1) six library cost studies and surveys, "Allocation of Library Expenditures to Research and Instruction" (University of Pennsylvania), "Sampling of Current Monograph…

  3. Standardization and optimization of fluorescence in situ hybridization (FISH) for HER-2 assessment in breast cancer: A single center experience.

    PubMed

    Bogdanovska-Todorovska, Magdalena; Petrushevska, Gordana; Janevska, Vesna; Spasevska, Liljana; Kostadinova-Kunovska, Slavica

    2018-05-20

    Accurate assessment of human epidermal growth factor receptor 2 (HER-2) is crucial in selecting patients for targeted therapy. Commonly used methods for HER-2 testing are immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH). Here we presented the implementation, optimization and standardization of two FISH protocols using breast cancer samples and assessed the impact of pre-analytical and analytical factors on HER-2 testing. Formalin fixed paraffin embedded (FFPE) tissue samples from 70 breast cancer patients were tested for HER-2 using PathVysion™ HER-2 DNA Probe Kit and two different paraffin pretreatment kits, Vysis/Abbott Paraffin Pretreatment Reagent Kit (40 samples) and DAKO Histology FISH Accessory Kit (30 samples). The concordance between FISH and IHC results was determined. Pre-analytical and analytical factors (i.e., fixation, baking, digestion, and post-hybridization washing) affected the efficiency and quality of hybridization. The overall hybridization success in our study was 98.6% (69/70); the failure rate was 1.4%. The DAKO pretreatment kit was more time-efficient and resulted in more uniform signals that were easier to interpret, compared to the Vysis/Abbott kit. The overall concordance between IHC and FISH was 84.06%, kappa coefficient 0.5976 (p < 0.0001). The greatest discordance (82%) between IHC and FISH was observed in IHC 2+ group. A standardized FISH protocol for HER-2 assessment, with high hybridization efficiency, is necessary due to variability in tissue processing and individual tissue characteristics. Differences in the pre-analytical and analytical steps can affect the hybridization quality and efficiency. The use of DAKO pretreatment kit is time-saving and cost-effective.

  4. Detection of novel polymorphisms in the ckit gene of canine patients with lymphoma, melanoma, haemangiosarcoma, and osteosarcoma.

    PubMed

    Gramer, Irina; Kessler, Martin; Geyer, Joachim

    2016-06-01

    Tyrosine kinase inhibitors (TKIs) that specifically target cKIT represent a therapeutic approach for non-resectable canine mast cell tumours (MCTs) grade II/III. The therapeutic benefit of TKIs has been investigated in other tumours based on clinical response rates and identification of gain-of-function mutations. In the present study, cKIT expression in 14 dogs with osteosarcoma, melanoma, haemangiosarcoma, lymphoma, and fibrosarcoma was analysed. Tissue samples were used for cKIT sequencing to (I) detect the cKIT transcript and to (II) identify gain-of-function mutations. The cKIT transcript was detected in ten patients. Four novel amino acid substitutions and five silent polymorphisms were identified. Furthermore, an insertion mutation (GNSK) was discovered in the tissue, but not in the blood sample of one dog. CKIT expression was identified in a variety of canine tumours and, therefore, TKIs might have a broader therapeutic indication apart from treatment of MCTs. Further investigations will be necessary to localize the cKIT protein in the respective tumours and to evaluate the functional consequence of the cKIT variants identified in the present study.

  5. Evaluation of Two Commercial Enzyme-Linked Immunosorbent Assay Kits for the Detection of Human Circulating Metrnl.

    PubMed

    Zheng, Si-Li; Li, Zhi-Yong; Zhang, Zheng; Wang, Dong-Sheng; Xu, Jian; Miao, Chao-Yu

    2018-04-01

    Metrnl is a newly discovered secreted protein with neurotrophic activity and metabolic effect, while in earlier studies its circulating level in human was not explored. We evaluated two commercial enzyme-linked immunosorbent assay kits (DY7867-05, R&D Systems and SK00478-02, Aviscera Bioscience) for the detection of human circulating Metrnl. The DY7867-05 kit showed superiority over the SK00478-02 kit since it generated better curve fitting degree, smaller variation among tests, higher inter-assay reproducibility and better specificity, and could effectively detect human Metrnl in six types of blood samples. Subsequent analysis was performed using the DY7867-05 kit. Sample storage conditions were investigated. No gender difference in circulating Metrnl levels was found, while people with newly diagnosed type 2 diabetes mellitus (T2DM) had significantly lower Metrnl levels compared to the healthy controls.

  6. C-MORE Science Kits: Putting Technology in the Hands of K-12 Teachers and Students

    NASA Astrophysics Data System (ADS)

    Achilles, K.; Weersing, K.; Daniels, C.; Puniwai, N.; Matsuzaki, J.; Bruno, B. C.

    2008-12-01

    The Center for Microbial Oceanography: Research and Education (C-MORE) is a NSF Science and Technology Center based at the University of Hawaii. The C-MORE education and outreach program offers a variety of resources and professional development opportunities for science educators, including online resources, participation in oceanography research cruises, teacher-training workshops, mini-grants to incorporate microbial oceanography-related content and activities into their classroom and, most recently, C- MORE science kits. C-MORE science kits provide hands-on classroom, field, and laboratory activities related to microbial oceanography for K-12 students. Each kit comes with complete materials and instructions, and is available free of charge to Hawaii's public school teachers. Several kits are available nationwide. C-MORE science kits cover a range of topics and technologies and are targeted at various grade levels. Here is a sampling of some available kits: 1) Marine Murder Mystery: The Case of the Missing Zooxanthellae. Students learn about the effect of climate change and other environmental threats on coral reef destruction through a murder-mystery experience. Participants also learn how to use DNA to identify a suspect. Grades levels: 3-8. 2) Statistical sampling. Students learn basic statistics through an exercise in random sampling, with applications to microbial oceanography. The laptops provided with this kit enable students to enter, analyze, and graph their data using EXCEL. Grades levels: 6-12. 3) Chlorophyll Lab. A research-quality fluorometer is used to measure the chlorophyll content in marine and freshwater systems. This enables students to compare biomass concentrations in samples collected from various locations. Grades levels: 9-12. 4) Conductivity-Temperature-Depth (CTD). Students predict how certain variables (e.g., temperature, pressure, chlorophyll, oxygen) vary with depth. A CTD, attached to a laptop computer, is deployed into deep water off a dock or a ship to collect real-time data and test their hypotheses. Grades levels: 9-12.

  7. Protein crystallography prescreen kit

    DOEpatents

    Segelke, Brent W.; Krupka, Heike I.; Rupp, Bernhard

    2007-10-02

    A kit for prescreening protein concentration for crystallization includes a multiplicity of vials, a multiplicity of pre-selected reagents, and a multiplicity of sample plates. The reagents and a corresponding multiplicity of samples of the protein in solutions of varying concentrations are placed on sample plates. The sample plates containing the reagents and samples are incubated. After incubation the sample plates are examined to determine which of the sample concentrations are too low and which the sample concentrations are too high. The sample concentrations that are optimal for protein crystallization are selected and used.

  8. Protein crystallography prescreen kit

    DOEpatents

    Segelke, Brent W.; Krupka, Heike I.; Rupp, Bernhard

    2005-07-12

    A kit for prescreening protein concentration for crystallization includes a multiplicity of vials, a multiplicity of pre-selected reagents, and a multiplicity of sample plates. The reagents and a corresponding multiplicity of samples of the protein in solutions of varying concentrations are placed on sample plates. The sample plates containing the reagents and samples are incubated. After incubation the sample plates are examined to determine which of the sample concentrations are too low and which the sample concentrations are too high. The sample concentrations that are optimal for protein crystallization are selected and used.

  9. Survey of undeclared egg allergen levels in the most frequently recalled food types (including products bearing precautionary labelling).

    PubMed

    Khuda, Sefat E; Sharma, Girdhari M; Gaines, Dennis; Do, Andrew B; Pereira, Marion; Chang, Michael; Ferguson, Martine; Williams, Kristina M

    2016-08-01

    Since the number of recalls involving undeclared allergens is commonly associated with bakery and snack foods, we aimed to determine the frequency of egg allergens in a large number of these products using two commercial enzyme-linked immunosorbent assay (ELISA) methods. Samples were chosen that either had no egg identified on the product label or which had an egg precautionary statement. Among all samples, egg protein was detected in 5% of products using a Morinaga (MO) kit and 1% of products using a R-Biopharm (RB) kit. For bakery samples, egg protein was detected in 6% of 363 samples with no precautionary labelling (6% by MO and 1% by RB kit) and 12% of 80 samples which had precautionary labelling. For snack samples, egg protein was detected in 2% of 371 samples with no precautionary labelling (2% by MO and < 1% by RB kit) and 5% of 21 samples which had precautionary labelling. The disagreement rates between two methods were 5.2% for bakery products and 2.6% for snack products. The sample repeatability was at an acceptable level for bakery (< 12.5%) and snack foods (< 7.5%) for each method. The relative standard deviation between test kits was high (103.1%) for bakery foods. Four bakery products without precautionary labelling had a higher level of egg protein per serving compared with the eliciting dose (ED10 of 3.7 mg protein) for egg allergic patients. These results highlight the fact that detection methodology plays a vital role for accurate labelling control and mitigation of risk for egg allergic consumers.

  10. Evaluation of a new APTIMA specimen collection and transportation kit for high-risk human papillomavirus E6/E7 messenger RNA in cervical and vaginal samples.

    PubMed

    Chernesky, Max; Jang, Dan; Gilchrist, Jodi; Elit, Laurie; Lytwyn, Alice; Smieja, Marek; Dockter, Janel; Getman, Damon; Reid, Jennifer; Hill, Craig

    2014-06-01

    An APTIMA specimen collection and transportation (SCT) kit was developed by Hologic/Gen-Probe. To compare cervical SCT samples to PreservCyt and SurePath samples and self-collected vaginal samples to physician-collected vaginal and cervical SCT samples. To determine ease and comfort of self-collection with the kit. Each woman (n = 580) self-collected a vaginal SCT, then filled out a questionnaire (n = 563) to determine ease and comfort of self-collection. Colposcopy physicians collected a vaginal SCT and cervical PreservCyt, SCT, and SurePath samples. Samples were tested by APTIMA HPV (AHPV) assay. Agreement between testing of cervical SCT and PreservCyt was 91.1% (κ = 0.82), and that of SurePath samples was 86.7% (κ = 0.72). Agreement of self-collected vaginal SCT to physician-collected SCT was 84.7% (κ = 0.68), and that of self-collected vaginal to cervical SCT was 82.0% (κ = 0.63). For 30 patients with CIN2+, AHPV testing of cervical SCT was 100% sensitive and 59.8% specific compared with PreservCyt (96.6% and 66.2%) and SurePath (93.3% and 70.9%). Vaginal SCT sensitivity was 86.7% for self-collection and 80.0% for physician collection. Most patients found that vaginal self-collection was easy, 5.3% reported some difficulty, and 87.6% expressed no discomfort. Cervical samples collected with the new SCT kit compared well to traditional liquid-based samples tested by AHPV. Although there was good agreement between self-collected and physician-collected samples with the SCT, in a limited number of 30 women, vaginal sampling identified fewer with CIN2+ precancerous cervical lesions than cervical SCT sampling. Comfort, ease of use, and detection of high-risk HPV demonstrated that the kit could be used for cervical and vaginal sampling.

  11. Cross-site comparison of ribosomal depletion kits for Illumina RNAseq library construction.

    PubMed

    Herbert, Zachary T; Kershner, Jamie P; Butty, Vincent L; Thimmapuram, Jyothi; Choudhari, Sulbha; Alekseyev, Yuriy O; Fan, Jun; Podnar, Jessica W; Wilcox, Edward; Gipson, Jenny; Gillaspy, Allison; Jepsen, Kristen; BonDurant, Sandra Splinter; Morris, Krystalynne; Berkeley, Maura; LeClerc, Ashley; Simpson, Stephen D; Sommerville, Gary; Grimmett, Leslie; Adams, Marie; Levine, Stuart S

    2018-03-15

    Ribosomal RNA (rRNA) comprises at least 90% of total RNA extracted from mammalian tissue or cell line samples. Informative transcriptional profiling using massively parallel sequencing technologies requires either enrichment of mature poly-adenylated transcripts or targeted depletion of the rRNA fraction. The latter method is of particular interest because it is compatible with degraded samples such as those extracted from FFPE and also captures transcripts that are not poly-adenylated such as some non-coding RNAs. Here we provide a cross-site study that evaluates the performance of ribosomal RNA removal kits from Illumina, Takara/Clontech, Kapa Biosystems, Lexogen, New England Biolabs and Qiagen on intact and degraded RNA samples. We find that all of the kits are capable of performing significant ribosomal depletion, though there are differences in their ease of use. All kits were able to remove ribosomal RNA to below 20% with intact RNA and identify ~ 14,000 protein coding genes from the Universal Human Reference RNA sample at >1FPKM. Analysis of differentially detected genes between kits suggests that transcript length may be a key factor in library production efficiency. These results provide a roadmap for labs on the strengths of each of these methods and how best to utilize them.

  12. Performance of Commercial Enzyme-Linked Immunosorbent Assays for Detection of Antibodies to Bordetella pertussis▿

    PubMed Central

    Riffelmann, M.; Thiel, K.; Schmetz, J.; Wirsing von Koenig, C. H.

    2010-01-01

    Measuring antibodies to Bordetella pertussis antigens is mostly done by enzyme-linked immunosorbent assays (ELISAs). We compared the performance of ELISA kits that were commercially available in Germany. Eleven measured IgG antibodies, and nine measured IgA antibodies. An in-house ELISA with purified antigens served as a reference method. Samples included two WHO reference preparations, the former Food and Drug Administration (FDA)/Center for Biologics Evaluation and Research (CBER) reference preparations, serum samples from patients with clinically suspected pertussis, and serum samples from patients having received a combined tetanus, diphtheria, and pertussis (Tdap) vaccination. Kits using pertussis toxin (PT) as an antigen showed linearity compared to the WHO Reference preparation (r2 between 0.82 and 0.99), and these kits could quantify antibodies according to the reference preparation. ELISA kits using mixed antigens showed no linear correlation to the reference preparations. Patient results were compared to results of in-house ELISAs using a dual cutoff of either ≥100 IU/ml anti-PT IgG or ≥40 IU/ml anti-PT IgG together with ≥12 IU/ml anti-PT IgA. The sensitivities of kits measuring IgG antibodies ranged between 0.84 and 1.00. The specificities of kits using PT as an antigen were between 0.81 and 0.93. The specificities of kits using mixed antigens were between 0.51 and 0.59 and were thus not acceptable. The sensitivities of kits measuring IgA antibodies ranged between 0.53 and 0.73, and the specificities were between 0.67 and 0.94, indicating that IgA antibodies may be of limited diagnostic value. Our data suggest that ELISAs should use purified PT as an antigen and be standardized to the 1st International Reference preparation. PMID:20943873

  13. Rapid Detection of the Varicella Zoster Virus

    NASA Technical Reports Server (NTRS)

    Lewis, Michelle P.; Harding, Robert

    2011-01-01

    1.Technology Description-Researchers discovered that when the Varicella Zoster Virus (VZV) reactivates from latency in the body, the virus is consistently present in saliva before the appearance of skin lesions. A small saliva sample is mixed with a specialized reagent in a test kit. If the virus is present in the saliva sample, the mixture turns a red color. The sensitivity and specificity emanates from an antibody-antigen reaction. This technology is a rapid, non-invasive, point of-of-care testing kit for detecting the virus from a saliva sample. The device is easy to use and can be used in clinics and in remote locations to quickly detect VZV and begin treatment with antiviral drugs. 2.Market Opportunity- RST Bioscience will be the first and only company to market a rapid, same day test kit for the detection of VZV in saliva. The RST detection test kit will have several advantages over existing, competitive technology. The test kit is self contained and laboratory equipment is not required for analysis of the sample. Only a single saliva sample is required to be taken instead of blood or cerebral spinal fluid. The test kit is portable, sterile and disposable after use. RST detection test kits require no electrical power or expensive storage equipment and can be used in remote locations. 3.Market Analysis- According to the CDC, it is estimated that 1 million cases of shingles occur each year in the U.S. with more than half over the age of sixty. There is a high demand for rapid diagnostics by the public. The point-of-care testing (POCT) market is growing faster than other segments of in vitro diagnostics. According to a July 2007 InteLab Corporation industry report the overall market for POCT was forecast to increase from $10.3 billion in 2005 to $18.7 billion by 2011. The market value of this test kit has not been determined. 4.Competition- The VZV vaccine prevents 50% of cases and reduces neuralgia by 66%. The most popular test detects VZV-specific IgM antibody in blood. Other tests include running a sample in a polymerase chain reaction analyzer, enzyme immunoassay, latex agglutination, indirect fluorescent antibody and fluorescent antibody to membrane antigen assay. These existing tests require laboratory analysis by trained personnel, expensive equipment, invasive procedures and a longer period of time to obtain test results.

  14. Evaluation of two platelet-rich plasma processing methods and two platelet-activation techniques for use in llamas and alpacas.

    PubMed

    Semevolos, Stacy A; Youngblood, Cori D; Grissom, Stephanie K; Gorman, M Elena; Larson, Maureen K

    2016-11-01

    OBJECTIVE To evaluate 2 processing methods (commercial kit vs conical tube centrifugation) for preparing platelet rich plasma (PRP) for use in llamas and alpacas. SAMPLES Blood samples (30 mL each) aseptically collected from 6 healthy llamas and 6 healthy alpacas. PROCEDURES PRP was prepared from blood samples by use of a commercial kit and by double-step conical tube centrifugation. A CBC was performed for blood and PRP samples. Platelets in PRP samples were activated by means of a freeze-thaw method with or without 23mM CaCl 2 , and concentrations of platelet-derived growth factor-BB and transforming growth factor-β 1 were measured. Values were compared between processing methods and camelid species. RESULTS Blood CBC values for llamas and alpacas were similar. The commercial kit yielded a significantly greater degree of platelet enrichment (mean increase, 8.5 fold vs 2.8 fold) and WBC enrichment (mean increase, 3.7 fold vs 1.9 fold) than did conical tube centrifugation. Llamas had a significantly greater degree of platelet enrichment than alpacas by either processing method. No difference in WBC enrichment was identified between species. Concentrations of both growth factors were significantly greater in PRP samples obtained by use of the commercial kit versus those obtained by conical tube centrifugation. CONCLUSIONS AND CLINICAL RELEVANCE For blood samples from camelids, the commercial kit yielded a PRP product with a higher platelet and WBC concentration than achieved by conical tube centrifugation. Optimal PRP platelet and WBC concentrations for various applications need to be determined for llamas and alpacas.

  15. Blood collection kit for Space Lab 1

    NASA Image and Video Library

    1981-02-02

    S81-26158 (Feb 1981) --- A close-up view of a training version of a STS-40/SLS-1 blood kit. Blood samples from crewmembers are critical to a number of Space Life Sciences-1 (SLS-1) investigations. One day's collection equipment, color coded for each crewmember, is neatly organized in the kit.

  16. 46 CFR 160.054-7 - Procedure for approval.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Kits, First-Aid, for Inflatable Liferafts § 160.054-7 Procedure... the first-aid kit. At the time of selection of the pre-approval sample, the manufacturer shall furnish... § 160.054-5 to determine the suitability of the first-aid kit for use in conjunction with lifesaving...

  17. 46 CFR 160.054-7 - Procedure for approval.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Kits, First-Aid, for Inflatable Liferafts § 160.054-7 Procedure... the first-aid kit. At the time of selection of the pre-approval sample, the manufacturer shall furnish... § 160.054-5 to determine the suitability of the first-aid kit for use in conjunction with lifesaving...

  18. 46 CFR 160.054-7 - Procedure for approval.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Kits, First-Aid, for Inflatable Liferafts § 160.054-7 Procedure... the first-aid kit. At the time of selection of the pre-approval sample, the manufacturer shall furnish... § 160.054-5 to determine the suitability of the first-aid kit for use in conjunction with lifesaving...

  19. 46 CFR 160.054-7 - Procedure for approval.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Kits, First-Aid, for Inflatable Liferafts § 160.054-7 Procedure... the first-aid kit. At the time of selection of the pre-approval sample, the manufacturer shall furnish... § 160.054-5 to determine the suitability of the first-aid kit for use in conjunction with lifesaving...

  20. Kit for the rapid preparation of .sup.99m Tc red blood cells

    DOEpatents

    Richards, Powell; Smith, Terry D.

    1976-01-01

    A method and sample kit for the preparation of .sup.99m Tc-labeled red blood cells in a closed, sterile system. A partially evacuated tube, containing a freeze-dried stannous citrate formulation with heparin as an anticoagulant, allows whole blood to be automatically drawn from the patient. The radioisotope is added at the end of the labeling sequence to minimize operator exposure. Consistent 97% yields in 20 minutes are obtained with small blood samples. Freeze-dried kits have remained stable after five months.

  1. Massively parallel sequencing of forensic STRs and SNPs using the Illumina® ForenSeq™ DNA Signature Prep Kit on the MiSeq FGx™ Forensic Genomics System.

    PubMed

    Guo, Fei; Yu, Jiao; Zhang, Lu; Li, Jun

    2017-11-01

    The ForenSeq™ DNA Signature Prep Kit (ForenSeq Kit) is designed to detect more than 200 forensically relevant markers in a single reaction on the MiSeq FGx™ Forensic Genomics System (MiSeq FGx System), including Amelogenin, 27 autosomal short tandem repeats (A-STRs), 7 X chromosomal STRs (X-STRs), 24 Y chromosomal STRs (Y-STRs) and 94 identity-informative single nucleotide polymorphisms (iSNPs) with the option to contain 22 phenotypic-informative SNPs (pSNPs) and 56 ancestry-informative SNPs (aSNPs). In this study, we evaluated the MiSeq FGx System on three major parts: methodological optimization (DNA extraction, sample quantification, library normalization, diluted libraries concentration, and sample-to-cell arrangement), massively parallel sequencing (MPS) performance (depth of coverage, sequence coverage ratio, and allele coverage ratio), and ForenSeq Kit characteristics (repeatability and concordance, sensitivity, mixture, stability and case-type samples). Results showed that quantitative polymerase chain reaction (qPCR)-based sample quantification and library normalization and the appropriate number of pooled libraries and concentration of diluted libraries provided a greater level of MPS performance and repeatability. Repeatable and concordant genotypes were obtained by the ForenSeq Kit. Full profiles were obtained from ≥100pg input DNA for STRs and ≥200pg for SNPs. A sample with ≥5% minor contributors was considered as a mixture by imbalanced allele coverage ratio distribution, and full profiles from minor contributors were easily detected between 9:1 and 1:9 mixtures with known reference profiles. The ForenSeq Kit tolerated considerable concentrations of inhibitors like ≤200μM hematin and ≤50μg/ml humic acid, and >56% STR profiles and >88% SNP profiles were obtained from ≥200-bp degraded samples. Also, it was adapted to case-type samples. As a whole, the ForenSeq Kit is a well-performed, robust, reliable, reproducible and highly informative assay, and it can fully meet requirements for human identification. Further, sensitive QC indicator and automated sample comparison function in the ForenSeq™ Universal Analysis Software are quite helpful, so that we can concentrate on questionable genotypes and avoid tedious and time-consuming labor to maximum the time spent in data analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Emergence of CTNNB1 mutation at acquired resistance to KIT inhibitor in metastatic melanoma.

    PubMed

    Cho, J; Kim, S Y; Kim, Y J; Sim, M H; Kim, S T; Kim, N K D; Kim, K; Park, W; Kim, J H; Jang, K-T; Lee, J

    2017-10-01

    The KIT inhibitor, imatinib, has shown promising efficacy in patients with KIT-mutated melanoma; however, acquisition of resistance to imatinib occurs rapidly in the majority of patients. The mechanisms of acquired resistance to imatinib in melanoma remain unclear. We analyzed biopsy samples from paired baseline and post-treatment tumor lesions in one patient with KIT-mutated melanoma who had had an initial objective tumor regression in response to imatinib treatment followed by disease progression 8 months later. Targeted deep sequencing from post-treatment biopsy samples detected an additional mutation in CTNNB1 (S33C) with original KIT L576P mutation. We examined the functional role of the additional CTNNB1 S33C mutation in resistance to imatinib indirectly using the Ba/F3 cell model. Ba/F3 cell lines transfected with both the L576P KIT mutation and the CTNNB1 S33C mutation demonstrated no growth inhibition despite imatinib treatment, whereas growth inhibition was observed in the Ba/F3 cell line transfected with the L576 KIT mutation alone. We report the first identification of the emergence of a CTNNB1 mutation that can confer acquired resistance to imatinib. Further investigation into the causes of acquired resistance to imatinib will be essential to improve the prognosis for patients with KIT-mutated melanoma.

  3. TruSeq Stranded mRNA and Total RNA Sample Preparation Kits

    Cancer.gov

    Total RNA-Seq enabled by ribosomal RNA (rRNA) reduction is compatible with formalin-fixed paraffin embedded (FFPE) samples, which contain potentially critical biological information. The family of TruSeq Stranded Total RNA sample preparation kits provides a unique combination of unmatched data quality for both mRNA and whole-transcriptome analyses, robust interrogation of both standard and low-quality samples and workflows compatible with a wide range of study designs.

  4. Arsenic exposure in drinking water: an unrecognized health threat in Peru

    PubMed Central

    Sima, Laura; Arias, M Helena Jahuira; Mihalic, Jana; Cabrera, Lilia Z; Danz, David; Checkley, William; Gilman, Robert H

    2014-01-01

    Abstract Objective To assess the extent of arsenic contamination of groundwater and surface water in Peru and, to evaluate the accuracy of the Arsenic Econo-Quick™ (EQ) kit for measuring water arsenic concentrations in the field. Methods Water samples were collected from 151 water sources in 12 districts of Peru, and arsenic concentrations were measured in the laboratory using inductively-coupled plasma mass spectrometry. The EQ field kit was validated by comparing a subset of 139 water samples analysed by laboratory measurements and the EQ kit. Findings In 86% (96/111) of the groundwater samples, arsenic exceeded the 10 µg/l arsenic concentration guideline given by the World Health Organization (WHO) for drinking water. In 56% (62/111) of the samples, it exceeded the Bangladeshi threshold of 50 µg/l; the mean concentration being 54.5 µg/l (range: 0.1–93.1). In the Juliaca and Caracoto districts, in 96% (27/28) of groundwater samples arsenic was above the WHO guideline; and in water samples collected from the section of the Rímac river running through Lima, all had arsenic concentrations exceeding the WHO limit. When validated against laboratory values, the EQ kit correctly identified arsenic contamination relative to the guideline in 95% (106/111) of groundwater and in 68% (19/28) of surface water samples. Conclusion In several districts of Peru, drinking water shows widespread arsenic contamination, exceeding the WHO arsenic guideline. This poses a public health threat requiring further investigation and action. For groundwater samples, the EQ kit performed well relative to the WHO arsenic limit and therefore could provide a vital tool for water arsenic surveillance. PMID:25177071

  5. Validation of two commercial real-time RT-PCR kits for rapid and specific diagnosis of classical swine fever virus.

    PubMed

    Le Dimna, M; Vrancken, R; Koenen, F; Bougeard, S; Mesplède, A; Hutet, E; Kuntz-Simon, G; Le Potier, M F

    2008-01-01

    Two real-time RT-PCR kits, developed by LSI (TaqVet CSF) and ADIAGENE (Adiavet CSF), obtained an agreement to be commercialised in France, subject to conditions, defined by the French Classical Swine Fever (CSF) National Reference Laboratory. The producers were asked to introduce an internal control to check the RNA extraction efficacy. The different criteria assessed were sensitivity, "pestivirus specificity", reproducibility and ease of handling, using 189 different samples. These samples were either CSFV inactivated strains or blood/serum/organs collected from CSFV experimentally infected pigs or naturally infected wild boars. The reproducibility of the assays was confirmed by the analysis of a batch-to-batch panel control that was used for inter-laboratory tests involving nine laboratories. The two kits were also tested for the use in mass diagnostics and the results proved the kits to be suited using pools of blood, serum and tonsils. Moreover, a field evaluation, carried out on spleen samples collected from the CSF surveillance of wild boars in an area known to be infected and from domestic pigs at a slaughterhouse, confirmed the high sensitivity and specificity of the two kits. This step-by-step evaluation procedure confirmed that the two commercial CSF real-time RT-PCR kits have a higher predictive value than the current diagnostic standard, Virus Isolation.

  6. Performance evaluation of the HepB Typer-Entecavir kit for detection of entecavir resistance mutations in chronic hepatitis B.

    PubMed

    Ahn, Sang Hoon; Chun, Ji-Yong; Shin, Soo-Kyung; Park, Jun Yong; Yoo, Wangdon; Hong, Sun Pyo; Kim, Soo-Ok; Han, Kwang-Hyub

    2013-12-01

    Molecular diagnostic methods have enabled the rapid diagnosis of drug-resistant mutations in hepatitis B virus (HBV) and have reduced both unnecessary therapeutic interventions and medical costs. In this study we evaluated the analytical and clinical performances of the HepB Typer-Entecavir kit (GeneMatrix, Korea) in detecting entecavir-resistance-associated mutations. The HepB Typer-Entecavir kit was evaluated for its limit of detection, interference, cross-reactivity, and precision using HBV reference standards made by diluting high-titer viral stocks in HBV-negative human serum. The performance of the HepB Typer-Entecavir kit for detecting mutations related to entecavir resistance was compared with direct sequencing for 396 clinical samples from 108 patients. Using the reference standards, the detection limit of the HepB Typer-Entecavir kit was found to be as low as 500 copies/mL. No cross-reactivity was observed, and elevated levels of various interfering substances did not adversely affect its analytical performance. The precision test conducted by repetitive analysis of 2,400 replicates with reference standards at various concentrations showed 99.9% agreement (2398/2400). The overall concordance rate between the HepB Typer-Entecavir kit and direct sequencing assays in 396 clinical samples was 99.5%. The HepB Typer-Entecavir kit showed high reliability and precision, and comparable sensitivity and specificity for detecting mutant virus populations in reference and clinical samples in comparison with direct sequencing. Therefore, this assay would be clinically useful in the diagnosis of entecavir-resistance-associated mutations in chronic hepatitis B.

  7. Evaluation of ELISA tests specific for Shiga toxin 1 and 2 in food and water samples

    USDA-ARS?s Scientific Manuscript database

    Two enzyme-linked immunosorbent assay (ELISA) kits were evaluated for their effectiveness in detecting and differentiating between Shiga toxin 1 and 2 (Stx1 and Stx2) produced by Shiga toxin-producing E. coli (STEC) inoculated into food and water samples. Each kit incorporated monoclonal antibodies ...

  8. Vitamin B12 absorption judged by measurement of holotranscobalamin, active vitamin B12: evaluation of a commercially available EIA kit.

    PubMed

    Greibe, Eva; Nexo, Ebba

    2011-11-01

    Active vitamin B12 absorption is followed by an increase in holotranscobalamin (holoTC) upon loading with a high physiological dose of the vitamin (the CobaSorb test). This study evaluates the use of a newly launched EIA kit for measurement of holoTC (active B12) in relation to the CobaSorb test. Intra-assay imprecision and linearity of the EIA kit was examined, employing serum pools of increasing holoTC concentrations. For the CobaSorb test, holoTC was measured before and after loading with 3-times 9 μg of vitamin B12 employing both the in-house ELISA and the EIA kit (n=25). The EIA kit showed an intra-assay CV between 2.2% and 5.8% for holoTC values ranging from 21 to 80 pmol/L. Employing diluted serum samples resulted in spurious high values of holoTC. The EIA kit performed well in relation to the CobaSorb test and classified the patients studied as capable of absorbing vitamin B12 (n=10) or not (n=15), as did the in-house ELISA. The Active B12 (holoTC) EIA kit proved suitable for use with the CobaSorb test, but not for analysis of diluted serum samples.

  9. Evaluation of three high abundance protein depletion kits for umbilical cord serum proteomics

    PubMed Central

    2011-01-01

    Background High abundance protein depletion is a major challenge in the study of serum/plasma proteomics. Prior to this study, most commercially available kits for depletion of highly abundant proteins had only been tested and evaluated in adult serum/plasma, while the depletion efficiency on umbilical cord serum/plasma had not been clarified. Structural differences between some adult and fetal proteins (such as albumin) make it likely that depletion approaches for adult and umbilical cord serum/plasma will be variable. Therefore, the primary purposes of the present study are to investigate the efficiencies of several commonly-used commercial kits during high abundance protein depletion from umbilical cord serum and to determine which kit yields the most effective and reproducible results for further proteomics research on umbilical cord serum. Results The immunoaffinity based kits (PROTIA-Sigma and 5185-Agilent) displayed higher depletion efficiency than the immobilized dye based kit (PROTBA-Sigma) in umbilical cord serum samples. Both the PROTIA-Sigma and 5185-Agilent kit maintained high depletion efficiency when used three consecutive times. Depletion by the PROTIA-Sigma Kit improved 2DE gel quality by reducing smeared bands produced by the presence of high abundance proteins and increasing the intensity of other protein spots. During image analysis using the identical detection parameters, 411 ± 18 spots were detected in crude serum gels, while 757 ± 43 spots were detected in depleted serum gels. Eight spots unique to depleted serum gels were identified by MALDI- TOF/TOF MS, seven of which were low abundance proteins. Conclusions The immunoaffinity based kits exceeded the immobilized dye based kit in high abundance protein depletion of umbilical cord serum samples and dramatically improved 2DE gel quality for detection of trace biomarkers. PMID:21554704

  10. Shuttle Kit Freezer Refrigeration Unit Conceptual Design

    NASA Technical Reports Server (NTRS)

    Copeland, R. J.

    1975-01-01

    The refrigerated food/medical sample storage compartment as a kit to the space shuttle orbiter is examined. To maintain the -10 F in the freezer kit, an active refrigeration unit is required, and an air cooled Stirling Cycle refrigerator was selected. The freezer kit contains two subsystems, the refrigeration unit, and the storage volume. The freezer must provide two basic capabilities in one unit. One requirement is to store 215 lbs of food which is consumed in a 30-day period by 7 people. The other requirement is to store 128.3 lbs of medical samples consisting of both urine and feces. The unit can be mounted on the lower deck of the shuttle cabin, and will occupy four standard payload module compartments on the forward bulkhead. The freezer contains four storage compartments.

  11. Design of Indigenous ELISA Using Tachyzoites from the RH Strain of Toxoplasma gondii and Comparison with Commercial Kits in Ahvaz, Southwest of Iran, 2015.

    PubMed

    Mohammadpour, Niloofar; Saki, Jasem; Rafiei, Abdollah; Khodadadi, Ali; Tavalla, Mehdi; Cheraghian, Bahman

    2016-10-01

    Toxoplasma gondii is one of the most common causes of latent infections in humans worldwide. Detecting anti- Toxoplasma antibodies in serum using serological tests is a common method to diagnose toxoplasmosis. In the present study, an indigenous ELISA kit was prepared using tachyzoites from the RH strain of T. gondii , and its sensitivity and specificity were compared with those of commercial kits. To produce antigens, 0.02 mL of locally isolated T. gondii RH strain parasites along with 10 9 tachyzoites were injected into the peritoneal cavities of 50 laboratory mice (BALB/C). Parasites were collected after 4 days. After filtering and washing, the concentration of protein in sonicated tachyzoites was calculated using the Lowry protein assay. The dilution of antigen, serum and alkaline phosphatase conjugate was assessed in designing an indigenous ELISA method; then ELISA was performed based on these dilutions, and its sensitivity was determined using 200 serum samples. In addition, the specificity of the assay was evaluated using 40 serum samples from patients with tuberculosis, leukemia or hydatid cyst. Indigenous ELISA was used to examine 100 serum samples containing anti- T. gondii IgG, with a sensitivity of 98% (commercial kits: 100%). Another 100 serum samples containing anti- T. gondii IgM were also tested, with a sensitivity of 99% (commercial kits: 100%). When 40 serum samples from patients with leukemia, hydatid cyst or tuberculosis were examined using anti- T. gondii IgG, the specificity was 100%, identical to commercial kits. However, the specificity of a similar test with anti- T. gondii IgM was just 28.6% for serum samples from leukemia patients, 21.4% for hydatid cyst and 16.7% for tuberculosis. We found that purified locally isolated soluble crude antigens of the RH strain of T. gondii from the peritoneal cavity of mice may be one of the most promising antigens for detection of human toxoplasmosis in routine screening.

  12. Development of Experiment Kits for Processing Biological Samples In-Flight on SLS-2

    NASA Technical Reports Server (NTRS)

    Jaquez, R.; Savage, P. D.; Hinds, W. E.; Evans, J.; Dubrovin, L.

    1994-01-01

    The design of the hematology experiment kits for SLS-2 has resulted in a modular, flexible configuration which maximizes crew efficiency and minimizes error and confusion when dealing with over 1200 different components over the course of the mission. The kit layouts proved to be very easy to use and their packaging design provided for positive, secure containment of the many small components. The secondary Zero(Tm) box enclosure also provided an effective means for transport of the kits within the Spacelab and for grouping individual kits by flight day usage. The kits are readily adaptable to use on future flights by simply replacing the inner components as required and changing the labelling scheme to match new mission requirements.

  13. Japanese Reference Panel of Blood Specimens for Evaluation of Hepatitis C Virus RNA and Core Antigen Quantitative Assays

    PubMed Central

    Murayama, Asako; Sugiyama, Nao; Watashi, Koichi; Masaki, Takahiro; Suzuki, Ryosuke; Aizaki, Hideki; Mizuochi, Toshiaki; Wakita, Takaji

    2012-01-01

    An accurate and reliable quantitative assay for hepatitis C virus (HCV) is essential for measuring viral propagation and the efficacy of antiviral therapy. There is a growing need for domestic reference panels for evaluation of clinical assay kits because the performance of these kits may vary with region-specific genotypes or polymorphisms. In this study, we established a reference panel by selecting 80 donated blood specimens in Japan that tested positive for HCV. Using this panel, we quantified HCV viral loads using two HCV RNA kits and five core antigen (Ag) kits currently available in Japan. The data from the two HCV RNA assay kits showed excellent correlation. All RNA titers were distributed evenly across a range from 3 to 7 log IU/ml. Although the data from the five core Ag kits also correlated with RNA titers, the sensitivities of individual kits were not sufficient to quantify viral load in all samples. As calculated by the correlation with RNA titers, the theoretical lower limits of detection by these core Ag assays were higher than those for the detection of RNA. Moreover, in several samples in our panel, core Ag levels were underestimated compared to RNA titers. Sequence analysis in the HCV core region suggested that polymorphisms at amino acids 47 to 49 of the core Ag were responsible for this underestimation. The panel established in this study will be useful for estimating the quality of currently available and upcoming HCV assay kits; such quality control is essential for clinical usage of these kits. PMID:22495557

  14. Efficacy of a lead based paint XRF analyzer and a commercially available colorimetric lead test kit as qualitative field tools for determining presence of lead in religious powders.

    PubMed

    Shah, Manthan P; Shendell, Derek G; Meng, Qingyu; Ohman-Strickland, Pamela; Halperin, William

    2018-04-23

    The performances of a portable X-Ray Fluorescence (XRF) lead paint analyzer (RMD LPA-1, Protec Instrument Corp., Waltham, MA) and a commercially available colorimetric lead test kit (First Alert Lead Test Kit, eAccess Solutions, Inc., Palatine, IL) were evaluated for use by local or state health departments as potential cost-effective rapid analysis or "spot test" field techniques for tentative identification of lead content in sindoor powders. For both field-sampling methods, sensitivity, specificity and predictive values varied widely for samples containing <300,000 μg/g lead. For samples containing ≥300,000 μg/g lead, the aforementioned metrics were 100% (however, the CIs had a wide range). In addition, both field sampling methods showed clear, consistent positive readings only for samples containing ≥300,000 μg/g lead. Even samples with lead content as high as 5,110 μg/g were not positively identified by either field analysis technique. The results of this study suggest the XRF analyzer and colorimetric lead test kit cannot be used as a rapid field test for sindoor by health department inspectors.

  15. [Effect evaluation of three ELISA kits in detection of fasciolasis].

    PubMed

    Ai, Lin; Chen, Mu-Xin; Chen, Shao-Hong; Chu, Yan-Hong; Cai, Yu-Chun; Zhou, Xiao-Nong; Chen, Jia-Xu

    2013-04-01

    To evaluate the effect of 3 ELISA kits on detection of human fasciolasis. Twenty-six serum samples from patients with fasciolasis, 180 serum samples from patients with other parasitic diseases as well as 26 serum samples from healthy people were detected by ELISA kits which using soluble antigen of Fasciola gigantica, Fasciola hepatica (Fg-ELISA and Fh-ELISA) as well as IgG antigen ELISA detection kits made by DRG company in Germany. The effects of the 3 kits were evaluated. The sensitivities of Fg-ELISA, Fh-ELISA, and DRG-ELISA were 100.0%, 80.8% (95% CI: 65.7%-95.9%) and 100.0%, respectively; the specificities of the three were 87.9% (95% CI: 83.5%-92.4%), 85.0%(95% CI: 80.1%-89.9%) and 83.5% (95% CI: 78.4%-88.6%), respectively, and Youden indexes of them were 0.88, 0.66 and 0.84, respectively. The detection rate of Fg-ELISA (100%) was significantly higher than that of Fh-ELISA (80.8%) (P < 0.05). The A absolute value (A/CO) of Fg-ELISA was 1.70, which was also significantly higher than the value of Fh-ELISA (1.18) (P < 0.000 1). Fg-ELISA has a good detection effect and low cost, and is more suitable than Fh-ELISA and DRG-ELISA for clinical sample tests as well as massive screening in fasciolasis endemic areas in southwest China.

  16. Development and validation of an ELISA kit for the detection of ricin toxins from biological specimens and environmental samples.

    PubMed

    Chen, Hsiao Ying; Tran, Hung; Foo, Ling Yann; Sew, Tracey Wenhui; Loke, Weng Keong

    2014-08-01

    Ricin is a toxin that can be easily extracted from seeds of Ricinus communis plants. Ricin is considered to be a major bio-threat as it can be freely and easily acquired in large quantities. A deliberate release of such toxin in civilian populations would very likely overwhelm existing public health systems, resulting in public fear and social unrest. There is currently no commercially available or FDA-approved prophylaxis such as vaccines, or therapeutic antitoxins or antidotes, available for ricin intoxication. Patient treatment is typically supportive care based on symptoms, often designed to reinforce the body's natural response. This paper describes the development and validation of a robust ELISA test kit, which can be used to screen for ricin in biological specimens such as whole blood and faeces. Faecal specimens are shown in this study to have better diagnostic sensitivity and a wider diagnostic window compared to whole blood. From these results, it is concluded that faeces is the most suitable clinical specimen for diagnosis of ricin poisoning via the oral route. The ELISA test kit can also detect ricin in environmental samples. An advantage of this ELISA kit over other commercial off-the-shelf (COTS) detection kits currently on the market that are developed to screen environmental samples only is its ability to diagnose ricin poisoning from clinical specimens as well as detect ricin from environmental samples.

  17. A Field Evaluation of the Hardy TB MODS Kit™ for the Rapid Phenotypic Diagnosis of Tuberculosis and Multi-Drug Resistant Tuberculosis

    PubMed Central

    Martin, Laura; Coronel, Jorge; Faulx, Dunia; Valdez, Melissa; Metzler, Mutsumi; Crudder, Chris; Castillo, Edith; Caviedes, Luz; Grandjean, Louis; Rodriguez, Mitzi; Friedland, Jon S.; Gilman, Robert H.; Moore, David A. J.

    2014-01-01

    Background Even though the WHO-endorsed, non-commercial MODS assay offers rapid, reliable TB liquid culture and phenotypic drug susceptibility testing (DST) at lower cost than any other diagnostic, uptake has been patchy. In part this reflects misperceptions about in-house assay quality assurance, but user convenience of one-stop procurement is also important. A commercial MODS kit was developed by Hardy Diagnostics (Santa Maria, CA, USA) with PATH (Seattle, WA, USA) to facilitate procurement, simplify procedures through readymade media, and enhance safety with a sealing silicone plate lid. Here we report the results from a large-scale field evaluation of the MODS kit in a government service laboratory. Methods & Findings 2446 sputum samples were cultured in parallel in Lowenstein-Jensen (LJ), conventional MODS and in the MODS kit. MODS kit DST was compared with conventional MODS (direct) DST and proportion method (indirect) DST. 778 samples (31.8%) were Mycobacterium tuberculosis culture-positive. Compared to conventional MODS the sensitivity, specificity, positive, and negative predictive values (95% confidence intervals) of the MODS Kit were 99.3% (98.3–99.8%), 98.3% (97.5–98.8%), 95.8% (94.0–97.1%), and 99.7% (99.3–99.9%). Median (interquartile ranges) time to culture-positivity (and rifampicin and isoniazid DST) was 10 (9–13) days for conventional MODS and 8.5 (7–11) for MODS Kit (p<0.01). Direct rifampicin and isoniazid DST in MODS kit was almost universally concordant with conventional MODS (97.9% agreement, 665/679 evaluable samples) and reference indirect DST (97.9% agreement, 687/702 evaluable samples). Conclusions MODS kit delivers performance indistinguishable from conventional MODS and offers a convenient, affordable alternative with enhanced safety from the sealing silicone lid. The availability in the marketplace of this platform, which conforms to European standards (CE-marked), readily repurposed for second-line DST in the near future, provides a fresh opportunity for improving equity of access to TB diagnosis and first and second-line DST in settings where the need is greatest. PMID:25225802

  18. A field evaluation of the Hardy TB MODS Kit™ for the rapid phenotypic diagnosis of tuberculosis and multi-drug resistant tuberculosis.

    PubMed

    Martin, Laura; Coronel, Jorge; Faulx, Dunia; Valdez, Melissa; Metzler, Mutsumi; Crudder, Chris; Castillo, Edith; Caviedes, Luz; Grandjean, Louis; Rodriguez, Mitzi; Friedland, Jon S; Gilman, Robert H; Moore, David A J

    2014-01-01

    Even though the WHO-endorsed, non-commercial MODS assay offers rapid, reliable TB liquid culture and phenotypic drug susceptibility testing (DST) at lower cost than any other diagnostic, uptake has been patchy. In part this reflects misperceptions about in-house assay quality assurance, but user convenience of one-stop procurement is also important. A commercial MODS kit was developed by Hardy Diagnostics (Santa Maria, CA, USA) with PATH (Seattle, WA, USA) to facilitate procurement, simplify procedures through readymade media, and enhance safety with a sealing silicone plate lid. Here we report the results from a large-scale field evaluation of the MODS kit in a government service laboratory. 2446 sputum samples were cultured in parallel in Lowenstein-Jensen (LJ), conventional MODS and in the MODS kit. MODS kit DST was compared with conventional MODS (direct) DST and proportion method (indirect) DST. 778 samples (31.8%) were Mycobacterium tuberculosis culture-positive. Compared to conventional MODS the sensitivity, specificity, positive, and negative predictive values (95% confidence intervals) of the MODS Kit were 99.3% (98.3-99.8%), 98.3% (97.5-98.8%), 95.8% (94.0-97.1%), and 99.7% (99.3-99.9%). Median (interquartile ranges) time to culture-positivity (and rifampicin and isoniazid DST) was 10 (9-13) days for conventional MODS and 8.5 (7-11) for MODS Kit (p<0.01). Direct rifampicin and isoniazid DST in MODS kit was almost universally concordant with conventional MODS (97.9% agreement, 665/679 evaluable samples) and reference indirect DST (97.9% agreement, 687/702 evaluable samples). MODS kit delivers performance indistinguishable from conventional MODS and offers a convenient, affordable alternative with enhanced safety from the sealing silicone lid. The availability in the marketplace of this platform, which conforms to European standards (CE-marked), readily repurposed for second-line DST in the near future, provides a fresh opportunity for improving equity of access to TB diagnosis and first and second-line DST in settings where the need is greatest.

  19. [Comparison of Dengue viral nonstructural protein 1 antigen testing kits].

    PubMed

    Wu, D; Zhao, L Z; Wu, Y H; Zhang, H; Zhang, M; Tan, Q Q; Zhou, H Q; Zhang, F C; He, J F

    2018-02-06

    Objective: To investigate the sensitivity and specificity of commercial nonstructural protein 1 (NS1) testing kits for Dengue fever diagnose, and provide the evidence for diagnostic criteria revision. Methods: 300 PCR or virus isolation positive blood samples for dengue virus were collected from sentinel hospitals for dengue surveillance in Guangzhou, Dongguang and Zhongshang from May 2015 to Nov. 2016. At the same time, 308 PCR negative samples for Dengue virus were collected as control group. The information of the sample was collected using questionnaires. These samples were tested using imported and domestic ELISA and the colloidal gold-labeled kits that were widely used for detecting dengue NS1. Sensitivity, specificity and coincidence were calculated and analyzed, and Z hongshan's result was regarded as the reslut of the third part. Results: The positive group includes 133 males and 167 females, average ages are 47.2±13.3, 179, 110 and 11 of them is Dengue Ⅰ, Ⅱ and Ⅲ respectively. The negative group includes 154 males and 154 females, average ages are (40.1±11.6) years old. The sensitivity of domestic ELISA Kits (94.5%) is less than imported (99.5%), and the result has statistical significance (χ(2)=8.59, P= 0.030), the specificity is 99.7% and 97.7% respectively; The sensitivity of imported and domestic the colloidal gold-labeled Kits is 97.5% and 96.5% respectively, both of specificities are 100%. The sensitivity and specificity of Dengue Ⅰ for NS1 test are more than 97.0%. The sensitivity of domestic ELISA and gold-labeled Kits is 90.0% and 95.0%, and the specificity is 96.8% and 100% respectively for Dengue Ⅱ test. The sensitivity of imported ELISA and gold-labeled Kits is 100% and 98.0%, and the specificity is 99.4% and 100% respectively for Dengue Ⅱ test. The result of the third party show the sensitivity and specificity of domestic ELISA and gold-labeled Kits are 90.0% and 98.0%, the differences has statistical significance (χ(2)=5.67, P= 0.020). Conclusion: NS1 testing can be used as early dengue fever diagnose for higher sensitivity and specificity.

  20. Study and evaluation of Wondfo rapid diagnostic kit based on nano-gold immunochromatography assay for diagnosis of Plasmodium falciparum.

    PubMed

    Peng, Yunping; Wu, Junlin; Wang, Jihua; Li, Wenmei; Yu, Shujuan

    2012-04-01

    Malaria has been recognized as a human disease for thousands of years and remains one of the most common diseases affecting humans worldwide. Therefore, a method for rapidly detecting Plasmodium falciparum is necessary and useful. We have developed Wondfo rapid diagnostic kit based on nano-gold immunochromatography assay for the detection of P. falciparum in patient specimen. In the present study, we demonstrated the sensitivity and specificity of the rapid diagnostic kit in which nano-gold labeling techniques and the monoclonal antibodies against histidine-rich protein-2 of P. falciparum were used to establish two-antibody sandwich immunochromatographic assay for detecting P. falciparum. By using microscopic examination of blood smears as control, the sensitivity, specificity, and feasibility of Wondfo rapid diagnostic kit was determined in the prompt and accurate diagnosis of malaria. In this study, 1,558 blood samples were collected from outpatient clinics in China and detected by both Wondfo kit and microscopic examination. The Wondfo kit did not show cross-reaction with microfilaria, Toxoplasma gondii, and other parasites in the blood. The patient samples positive for rheumatoid factor, HIV, tuberculosis, and syphilis did not show false positivity when testing with Wondfo kit. The detection sensitivity and specificity of Wondfo rapid diagnostic kit were 95.49% and 99.53%, respectively. These results indicate that our rapid diagnostic assay may be useful for detecting P. falciparum in patient specimen.

  1. [Development of ELISA-kit of quantitative analysis for Zearalenone].

    PubMed

    Wang, Yu-ping; Ji, Rong; Jiang, Tao; Kang, Wei-jun

    2006-03-01

    To develope a rapid, sensitive, quantitative ELISA-kit for Zearalenone and determine zearalenone in cereals. On the base of monoclonal antibodies against ZEN, apply indirect ELISA to study the performance parameter of the kit. The limited concentration of detection of the ELISA-kit was 1ng/ml, linear range was 1-200 ng/ml, the linear equation was Y = 0.99 - 0.40 x (R2 = 0.99). The inhibition concentration of 50% against ZEN was 16.3 ng/ml. The average recovery rate of spiked corn and wheat was 96.5% and 95.5%, respectively, the coefficient of variant was 13.2% and 10.9%, respectively. The kit can be stored at 4 degrees C over 6 months. The cross reaction rate with the other mycotoxins was less than 1%, and coefficient of variant within-laboratory and between-laboratory was less than 15% and less than 20%, respectively. Detecting the VICAM sample with ELISA method and HPLC method, the results were within the range of the sample, and there was no statistic difference between the two methods. This ELISA-kit was quick, sensitive, stable and specific and can be used to determine ZEN in cereals.

  2. Immunochemical analytical methods for the determination of peanut proteins in foods.

    PubMed

    Whitaker, Thomas B; Williams, Kristina M; Trucksess, Mary W; Slate, Andrew B

    2005-01-01

    Peanut proteins can cause allergenic reactions that can result in respiratory and circulatory effects in the body sometimes leading to shock and death. The determination of peanut proteins in foods by analytical methods can reduce the risk of serious reactions in the highly sensitized individual by allowing for the detection of these proteins in a food at various stages of the manufacturing process. The method performance of 4 commercially available enzyme-linked immunosorbent assay (ELISA) kits was evaluated for the detection of peanut proteins in milk chocolate, ice cream, cookies, and breakfast cereals: ELISA-TEK Peanut Protein Assay, now known as "Bio-Kit" for peanut proteins, from ELISA Technologies Inc.; Veratox for Peanut Allergens from Neogen Corp.; RIDASCREEN Peanut Kit from R-Biopharm GmbH; and ProLisa from Canadian Food Technology Ltd. The 4 test kits were evaluated for accuracy (recovery) and precision using known concentrations of peanut or peanut proteins in the 4 food matrixes. Two different techniques, incurred and spiked, were used to prepare samples with 4 known concentrations of peanut protein. Defatted peanut flour was added in the incurred samples, and water-soluble peanut proteins were added in the spiked samples. The incurred levels were 0.0, 10, 20, and 100 microg whole peanut per g food; the spiked levels were 0.0, 5, 10, and 20 microg peanut protein per g food. Performance varied by test kit, protein concentration, and food matrix. The Veratox kit had the best accuracy or lowest percent difference between measured and incurred levels of 15.7% when averaged across all incurred levels and food matrixes. Recoveries associated with the Veratox kit varied from 93 to 115% for all food matrixes except cookies. Recoveries for all kits were about 50% for cookies. The analytical precision, as measured by the variance, increased with an increase in protein concentration. However, the coefficient of variation (CV) was stable across the 4 incurred protein levels and was 7.0% when averaged across the 4 food matrixes and analytical kits. The R-Biopharm test kit had the best precision or a CV of 4.2% when averaged across all incurred levels and food matrixes. Because measured protein values varied by test kit and food matrix, a method was developed to normalize or transform measured protein concentrations to an adjusted protein value that was equal to the known protein concentration. The normalization method adjusts measured protein values to equal the true protein value regardless of the type test kit or type food matrix.

  3. [Consistency study of PowerPlex 21 kit and Goldeneye 20A kit and forensic application].

    PubMed

    Ren, He; Liu, Ying; Zhang, Qing-Xia; Jiao, Zhang-Ping

    2014-06-01

    To ensure the consistency of genotype results for PowerPlex 21 kit and Goldeneye 20A kit. The STR loci were amplified in DNA samples from 205 unrelated individuals in Beijing Han population. And consistency of 19 overlap STR loci typing were observed. The genetic polymorphism of D1S1656 locus was obtained. All 19 overlap loci typing showed consistent. The proportion of peak height of heterozygous loci in two kits showed no statistical difference (P > 0.05). The observed heterozygosis of D1S1656 was 0.878. The discrimination power was 0.949. The excluding probability of paternity of triplet was 0.751. The excluding probability of paternity of diploid was 0.506. The polymorphism information content was 0.810. PowerPlex 21 kit and Goldeneye 20A kit present a good consistency. The primer design is reasonable. The polymorphism of D1S1656 is good. The two kits can be used for human genetic analysis, paternity test, and individual identification in forensic practice.

  4. Performance evaluation of the HepB Typer-Entecavir kit for detection of entecavir resistance mutations in chronic hepatitis B

    PubMed Central

    Ahn, Sang Hoon; Chun, Ji-Yong; Shin, Soo-Kyung; Park, Jun Yong; Yoo, Wangdon; Hong, Sun Pyo; Han, Kwang-Hyub

    2013-01-01

    Background/Aims Molecular diagnostic methods have enabled the rapid diagnosis of drug-resistant mutations in hepatitis B virus (HBV) and have reduced both unnecessary therapeutic interventions and medical costs. In this study we evaluated the analytical and clinical performances of the HepB Typer-Entecavir kit (GeneMatrix, Korea) in detecting entecavir-resistance-associated mutations. Methods The HepB Typer-Entecavir kit was evaluated for its limit of detection, interference, cross-reactivity, and precision using HBV reference standards made by diluting high-titer viral stocks in HBV-negative human serum. The performance of the HepB Typer-Entecavir kit for detecting mutations related to entecavir resistance was compared with direct sequencing for 396 clinical samples from 108 patients. Results Using the reference standards, the detection limit of the HepB Typer-Entecavir kit was found to be as low as 500 copies/mL. No cross-reactivity was observed, and elevated levels of various interfering substances did not adversely affect its analytical performance. The precision test conducted by repetitive analysis of 2,400 replicates with reference standards at various concentrations showed 99.9% agreement (2398/2400). The overall concordance rate between the HepB Typer-Entecavir kit and direct sequencing assays in 396 clinical samples was 99.5%. Conclusions The HepB Typer-Entecavir kit showed high reliability and precision, and comparable sensitivity and specificity for detecting mutant virus populations in reference and clinical samples in comparison with direct sequencing. Therefore, this assay would be clinically useful in the diagnosis of entecavir-resistance-associated mutations in chronic hepatitis B. PMID:24459645

  5. Profiling soil microbial communities with next-generation sequencing: the influence of DNA kit selection and technician technical expertise.

    PubMed

    Soliman, Taha; Yang, Sung-Yin; Yamazaki, Tomoko; Jenke-Kodama, Holger

    2017-01-01

    Structure and diversity of microbial communities are an important research topic in biology, since microbes play essential roles in the ecology of various environments. Different DNA isolation protocols can lead to data bias and can affect results of next-generation sequencing. To evaluate the impact of protocols for DNA isolation from soil samples and also the influence of individual handling of samples, we compared results obtained by two researchers (R and T) using two different DNA extraction kits: (1) MO BIO PowerSoil ® DNA Isolation kit (MO_R and MO_T) and (2) NucleoSpin ® Soil kit (MN_R and MN_T). Samples were collected from six different sites on Okinawa Island, Japan. For all sites, differences in the results of microbial composition analyses (bacteria, archaea, fungi, and other eukaryotes), obtained by the two researchers using the two kits, were analyzed. For both researchers, the MN kit gave significantly higher yields of genomic DNA at all sites compared to the MO kit (ANOVA; P  < 0.006). In addition, operational taxonomic units for some phyla and classes were missed in some cases: Micrarchaea were detected only in the MN_T and MO_R analyses; the bacterial phylum Armatimonadetes was detected only in MO_R and MO_T; and WIM5 of the phylum Amoebozoa of eukaryotes was found only in the MO_T analysis. Our results suggest the possibility of handling bias; therefore, it is crucial that replicated DNA extraction be performed by at least two technicians for thorough microbial analyses and to obtain accurate estimates of microbial diversity.

  6. miR-137 downregulates c-kit expression in acute myeloid leukemia.

    PubMed

    Hu, Yanping; Dong, Xiaolong; Chu, Guoming; Lai, Guangrui; Zhang, Bijun; Wang, Leitong; Zhao, Yanyan

    2017-06-01

    The oncogene c-kit plays a vital role in the pathogenesis of acute myeloid leukemia (AML). However, the mechanism of microRNAs targeting c-kit in AML has not been determined in detail. Moreover, the role miR-137 in tumor cell proliferation remains controversial. The aim of this work was to verify whether miR-137 targets c-kit and to research the biological effects of restoring miR-137 expression in leukemia cells. We found that miR-137 binds specifically to the 3'-UTR of c-kit and suppresses the expression and activities of c-kit. There is a negative correlation between miR-137 and c-kit expression in both patients and cell lines determined by screening large clinical samples. We found that miR-137 can inhibit proliferation, promote apoptosis, and induce differentiation of c-kit+ AML cells. We determined that miR-137 can participate in the leukemogenesis by regulating c-kit, which could be used as a therapeutic target for acute myeloid leukemia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. A "three-in-one" sample preparation method for simultaneous determination of B-group water-soluble vitamins in infant formula using VitaFast(®) kits.

    PubMed

    Zhang, Heng; Lan, Fang; Shi, Yupeng; Wan, Zhi-Gang; Yue, Zhen-Feng; Fan, Fang; Lin, Yan-Kui; Tang, Mu-Jin; Lv, Jing-Zhang; Xiao, Tan; Yi, Changqing

    2014-06-15

    VitaFast(®) test kits designed for the microbiological assay in microtiter plate format can be applied to quantitative determination of B-group water-soluble vitamins such as vitamin B12, folic acid and biotin, et al. Compared to traditional microbiological methods, VitaFast(®) kits significantly reduce sample processing time and provide greater reliability, higher productivity and better accuracy. Recently, simultaneous determination of vitamin B12, folic acid and biotin in one sample is urgently required when evaluating the quality of infant formulae in our practical work. However, the present sample preparation protocols which are developed for individual test systems, are incompatible with simultaneous determination of several analytes. To solve this problem, a novel "three-in-one" sample preparation method is herein developed for simultaneous determination of B-group water-soluble vitamins using VitaFast(®) kits. The performance of this novel "three-in-one" sample preparation method was systematically evaluated through comparing with individual sample preparation protocols. The experimental results of the assays which employed "three-in-one" sample preparation method were in good agreement with those obtained from conventional VitaFast(®) extraction methods, indicating that the proposed "three-in-one" sample preparation method is applicable to the present three VitaFast(®) vitamin test systems, thus offering a promising alternative for the three independent sample preparation methods. The proposed new sample preparation method will significantly improve the efficiency of infant formulae inspection. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. [Differentiation of influenza (Flu) type A, type B, and respiratory syncytial virus (RSV) by QuickNavi™-Flu+RSV].

    PubMed

    Kohiyama, Risa; Miyazawa, Takashi; Shibano, Nobuko; Inano, Koichi

    2014-01-01

    Because it is not easy to differentiate Influenza virus (Flu) from RS virus (RSV) just by clinical symptoms, to accurately diagnose those viruses in conjunction with patient's clinical symptoms, rapid diagnostic kits has been used separately for each of those viruses. In our new study, we have developed a new rapid diagnostic kit, QuickNavi™-Flu+RSV. The kit can detect Flu A, Flu B, and RSV antigens with a single sample collection and an assay. Total of 2,873 cases (including nasopharyngeal swabs and nasopharyngeal aspirates specimens) in 2010/2011 and 2011/2012 seasons were evaluated with QuickNavi™-Flu+RSV and a commercially available kit. Sensitivity, specificity, and accuracy of Flu type A, type B, and RSV were above 95% when compared to commercially available kits (QuickNavi™-Flu and QuickNavi™-RSV) and considered to be equivalent to the commercially available kits. In 2011/2012 season, RSV infections increased prior to Flu season and continued during the peak of the Flu season. The kit can contribute to accurate diagnosis of Flu and RSV infections since co-infection cases have also been reported during the 2011/2012 season. QuickNavi™-Flu+RSV is useful for differential diagnosis of respiratory infectious diseases since it can detect Flu type A, type B, and RSV virus antigens with a single sample collection.

  9. Evaluation of DNA extraction methods for Bacillus anthracis spores isolated from spiked food samples.

    PubMed

    Thomas, M C; Shields, M J; Hahn, K R; Janzen, T W; Goji, N; Amoako, K K

    2013-07-01

    Nine commercial DNA extraction kits were evaluated for the isolation of DNA from 10-fold serial dilutions of Bacillus anthracis spores using quantitative real-time PCR (qPCR). The three kits determined by qPCR to yield the most sensitive and consistent detection (Epicenter MasterPure Gram Positive; MoBio PowerFood; ABI PrepSeq) were subsequently tested for their ability to isolate DNA from trace amounts of B. anthracis spores (approx. 6·5 × 10(1) and 1·3 × 10(2)  CFU in 25 ml or 50 g of food sample) spiked into complex food samples including apple juice, ham, whole milk and bagged salad and recovered with immunomagnetic separation (IMS). The MasterPure kit effectively and consistently isolated DNA from low amounts of B. anthracis spores captured from food samples. Detection was achieved from apple juice, ham, whole milk and bagged salad from as few as 65 ± 14, 68 ± 8, 66 ± 4 and 52 ± 16 CFU, respectively, and IMS samples were demonstrated to be free of PCR inhibitors. Detection of B. anthracis spores isolated from food by IMS differs substantially between commercial DNA extraction kits; however, sensitive results can be obtained with the MasterPure Gram Positive kit. The extraction protocol identified herein combined with IMS is novel for B. anthracis and allows detection of low levels of B. anthracis spores from contaminated food samples. © Her Majesty the Queen in Right of Canada [2013]. Reproduced with the permission of the Canadian Food Inspection Agency.

  10. Performances of Four Helicobacter pylori Serological Detection Kits Using Stool Antigen Test as Gold Standard.

    PubMed

    Biranjia-Hurdoyal, Susheela D; Seetulsingh-Goorah, Sharmila P

    2016-01-01

    The aim was to determine the performances of four Helicobacter pylori serological detection kits in different target groups, using Amplified IDEIA™ Hp StAR™ as gold standard. Kits studied were Rapid Immunochromatoghraphic Hexagon, Helicoblot 2.1, an EIA IgG kit and EIA IgA kit. Stool and blood samples were collected from 162 apparently healthy participants (control) and 60 Type 2 diabetes mellitus (T2DM) patients. The performances of the four serological detection kits were found to be affected by gender, age, health status and ethnicity of the participants. In the control group, the Helicoblot 2.1 kit had the best performance (AUC = 0.85; p<0.05, accuracy = 86.4%), followed by EIA IgG (AUC = 0.75; p<0.05, accuracy = 75.2%). The Rapid Hexagon and EIA IgA kits had relatively poor performances. In the T2DM subgroup, the kits H2.1 and EIA IgG had best performances, with accuracies of 96.5% and 93.1% respectively. The performance of EIA IgG improved with adjustment of its cut-off value. The performances of the detection kits were affected by various factors which should be taken into consideration.

  11. Evaluation and optimization of microbial DNA extraction from fecal samples of wild Antarctic bird species

    PubMed Central

    Eriksson, Per; Mourkas, Evangelos; González-Acuna, Daniel; Olsen, Björn; Ellström, Patrik

    2017-01-01

    ABSTRACT Introduction: Advances in the development of nucleic acid-based methods have dramatically facilitated studies of host–microbial interactions. Fecal DNA analysis can provide information about the host’s microbiota and gastrointestinal pathogen burden. Numerous studies have been conducted in mammals, yet birds are less well studied. Avian fecal DNA extraction has proved challenging, partly due to the mixture of fecal and urinary excretions and the deficiency of optimized protocols. This study presents an evaluation of the performance in avian fecal DNA extraction of six commercial kits from different bird species, focusing on penguins. Material and methods: Six DNA extraction kits were first tested according to the manufacturers’ instructions using mallard feces. The kit giving the highest DNA yield was selected for further optimization and evaluation using Antarctic bird feces. Results: Penguin feces constitute a challenging sample type: most of the DNA extraction kits failed to yield acceptable amounts of DNA. The QIAamp cador Pathogen kit (Qiagen) performed the best in the initial investigation. Further optimization of the protocol resulted in good yields of high-quality DNA from seven bird species of different avian orders. Conclusion: This study presents an optimized approach to DNA extraction from challenging avian fecal samples. PMID:29152162

  12. Portable field kit for determining uranium in water

    USGS Publications Warehouse

    McHugh, John B.

    1979-01-01

    The pressing need for on-site field analyses of the uranium content of surface and ground waters has promoted the development of a simple, light-weight, relatively cheap, portable kit to make such determinations in the field. Forty to sixty water samples per day can be analyzed for uranium to less than 0.2 parts per billion. The kit was tested in the field with excellent results.

  13. qPCR in gastrointestinal stromal tumors: Evaluation of reference genes and expression analysis of KIT and the alternative receptor tyrosine kinases FLT3, CSF1-R, PDGFRB, MET and AXL

    PubMed Central

    2010-01-01

    Background Gastrointestinal stromal tumors (GIST) represent the most common mesenchymal tumors of the gastrointestinal tract. About 85% carry an activating mutation in the KIT or PDGFRA gene. Approximately 10% of GIST are so-called wild type GIST (wt-GIST) without mutations in the hot spots. In the present study we evaluated appropriate reference genes for the expression analysis of formalin-fixed, paraffin-embedded and fresh frozen samples from gastrointestinal stromal tumors. We evaluated the gene expression of KIT as well as of the alternative receptor tyrosine kinase genes FLT3, CSF1-R, PDGFRB, AXL and MET by qPCR. wt-GIST were compared to samples with mutations in KIT exon 9 and 11 and PDGFRA exon 18 in order to evaluate whether overexpression of these alternative RTK might contribute to the pathogenesis of wt-GIST. Results Gene expression variability of the pooled cDNA samples is much lower than the single reverse transcription cDNA synthesis. By combining the lowest variability values of fixed and fresh tissue, the genes POLR2A, PPIA, RPLPO and TFRC were chosen for further analysis of the GIST samples. Overexpression of KIT compared to the corresponding normal tissue was detected in each GIST subgroup except in GIST with PDGFRA exon 18 mutation. Comparing our sample groups, no significant differences in the gene expression levels of FLT3, CSF1R and AXL were determined. An exception was the sample group with KIT exon 9 mutation. A significantly reduced expression of CSF1R, FLT3 and PDGFRB compared to the normal tissue was detected. GIST with mutations in KIT exon 9 and 11 and in PDGFRA exon 18 showed a significant PDGFRB downregulation. Conclusions As the variability of expression levels for the reference genes is very high comparing fresh frozen and formalin-fixed tissue there is a strong need for validation in each tissue type. None of the alternative receptor tyrosine kinases analyzed is associated with the pathogenesis of wild-type or mutated GIST. It remains to be clarified whether an autocrine or paracrine mechanism by overexpression of receptor tyrosine kinase ligands is responsible for the tumorigenesis of wt-GIST. PMID:21171987

  14. Evaluation of an enzyme immunoassay for detection of dengue virus NS1 antigen in human serum.

    PubMed

    Dussart, Philippe; Labeau, Bhety; Lagathu, Gisèle; Louis, Philippe; Nunes, Marcio R T; Rodrigues, Sueli G; Storck-Herrmann, Cécile; Cesaire, Raymond; Morvan, Jacques; Flamand, Marie; Baril, Laurence

    2006-11-01

    We evaluated a one-step sandwich-format microplate enzyme immunoassay for detecting dengue virus NS1 antigen (Ag) in human serum by use of Platelia Dengue NS1 Ag kits (Bio-Rad Laboratories, Marnes La Coquette, France). We collected 299 serum samples from patients with dengue disease and 50 serum samples from patients not infected with dengue virus. For the 239 serum samples from patients with acute infections testing positive by reverse transcription-PCR and/or virus isolation for one of the four dengue virus serotypes, the sensitivity of the Platelia Dengue NS1 Ag kit was 88.7% (95% confidence interval, 84.0% to 92.4%). None of the serum samples from patients not infected with dengue virus tested positive with the Platelia Dengue NS1 Ag kit. A diagnostic strategy combining the Platelia Dengue NS1 Ag test for acute-phase sera and immunoglobulin M capture enzyme-linked immunosorbent assay for early-convalescent-phase sera increased sensitivity only from 88.7% to 91.9%. Thus, NS1 antigen detection with the Platelia Dengue NS1 Ag kit could be used for first-line testing for acute dengue virus infection in clinical diagnostic laboratories.

  15. Extraction of total nucleic acid based on silica-coated magnetic particles for RT-qPCR detection of plant RNA virus/viroid.

    PubMed

    Sun, Ning; Deng, Congliang; Zhao, Xiaoli; Zhou, Qi; Ge, Guanglu; Liu, Yi; Yan, Wenlong; Xia, Qiang

    2014-02-01

    In this study, a nucleic acid extraction method based on silica-coated magnetic particles (SMPs) and RT-qPCR assay was developed to detect Arabis mosaic virus (ArMV), Lily symptomless virus (LSV), Hop stunt viroid (HSVd) and grape yellow speckle viroid 1 (GYSVd-1). The amplification sequences of RT-qPCR were reversely transcribed in vitro as RNA standard templates. The standard curves covered six or seven orders of magnitude with a detection limit of 100 copies per each assay. Extraction efficiency of the SMPs method was evaluated by recovering spiked ssRNAs from plant samples and compared to two commercial kits (TRIzol and RNeasy Plant mini kit). Results showed that the recovery rate of SMPs method was comparable to the commercial kits when spiked ssRNAs were extracted from lily leaves, whereas it was two or three times higher than commercial kits when spiked ssRNAs were extracted from grapevine leaves. SMPs method was also used to extract viral nucleic acid from15 ArMV-positive lily leaf samples and 15 LSV-positive lily leaf samples. SMPs method did not show statistically significant difference from other methods on detecting ArMV, but LSV. The SMPs method has the same level of virus load as the TRIzol, and its mean virus load of was 0.5log10 lower than the RNeasy Plant mini kit. Nucleic acid was extracted from 19 grapevine-leaf samples with SMPs and the two commercial kits and subsequently screened for HSVd and GYSVd-1 by RT-qPCR. Regardless of HSVd or GYSVd-1, SMPs method outperforms other methods on both positive rate and the viroid load. In conclusion, SMPs method was able to efficiently extract the nucleic acid of RNA viruses or viroids, especially grapevine viroids, from lily-leaf or grapevine-leaf samples for RT-qPCR detection. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Solid phase microextraction field kit

    DOEpatents

    Nunes, Peter J.; Andresen, Brian D.

    2005-08-16

    A field kit for the collection, isolation and concentration of trace amounts of high explosives (HE), biological weapons (BW) and chemical weapons (CW) residues in air, soil, vegetation, swipe, and liquid samples. The field kit includes a number of Solid Phase Microextraction (SPME) fiber and syringe assemblies in a hermetically sealed transportation container or tubes which includes a sampling port, a number of extra SPME fiber and syringe assemblies, the fiber and syringe assemblies including a protective cap for the fiber, and an extractor for the protective cap, along with other items including spare parts, protective glove, and an instruction manual, all located in an airtight container.

  17. Comparison of three commercial IgG and IgM ELISA kits for the detection of tick-borne encephalitis virus antibodies.

    PubMed

    Ackermann-Gäumann, Rahel; Tritten, Marie-Lise; Hassan, Mona; Lienhard, Reto

    2018-05-01

    Tick-borne encephalitis (TBE) is endemic in many parts of Europe and Asia. The diagnosis of this disease is essentially based on the demonstration of specific antibodies. For reasons of simplicity, automatization and quick availability of test results, enzyme-linked immunosorbent assays (ELISAs) are the method of choice for serological diagnosis of TBE. Here, we evaluated three commercially available anti-TBEV IgG and IgM ELISAs using 251 serum samples: the SERION ELISA classic FSME Virus/TBE Virus IgG and IgM kit (Virion\\Serion), the RIDASCREEN ® FSME/TBE IgG and IgM kit (R-Biopharm), and the anti-FSME/TBE virus ELISA "Vienna" IgG/anti-FSME/TBE virus ELISA IgM kit (Euroimmun). In total, discrepant test results for IgG and/or IgM were observed for 37/251 (14.7 %) of tested samples; differences were statistically significant. Reference values defined by serum neutralization test (SNT, n = 25) or results provided by EQA organizers (n = 2) were established for a subset of samples. In relation to these values, false-positive results were observed mainly for Euroimmun Vienna IgG and RIDASCREEN IgG, whereas false-negative results were primarily observed for Virion\\Serion IgG and RIDASCREEN IgM kits. In routine diagnostics, specificity problems are of major relevance and may be addressed by analyzing the respective samples using SNT. Copyright © 2018 Elsevier GmbH. All rights reserved.

  18. DNA methylation profiling of genomic DNA isolated from urine in diabetic chronic kidney disease: A pilot study

    PubMed Central

    Sexton-Oates, Alexandra; Carmody, Jake; Ekinci, Elif I.; Dwyer, Karen M.; Saffery, Richard

    2018-01-01

    Aim To characterise the genomic DNA (gDNA) yield from urine and quality of derived methylation data generated from the widely used Illuminia Infinium MethylationEPIC (HM850K) platform and compare this with buffy coat samples. Background DNA methylation is the most widely studied epigenetic mark and variations in DNA methylation profile have been implicated in diabetes which affects approximately 415 million people worldwide. Methods QIAamp Viral RNA Mini Kit and QIAamp DNA micro kit were used to extract DNA from frozen and fresh urine samples as well as increasing volumes of fresh urine. Matched buffy coats to the frozen urine were also obtained and DNA was extracted from the buffy coats using the QIAamp DNA Mini Kit. Genomic DNA of greater concentration than 20μg/ml were used for methylation analysis using the HM850K array. Results Irrespective of extraction technique or the use of fresh versus frozen urine samples, limited genomic DNA was obtained using a starting sample volume of 5ml (0–0.86μg/mL). In order to optimize the yield, we increased starting volumes to 50ml fresh urine, which yielded only 0–9.66μg/mL A different kit, QIAamp DNA Micro Kit, was trialled in six fresh urine samples and ten frozen urine samples with inadequate DNA yields from 0–17.7μg/mL and 0–1.6μg/mL respectively. Sufficient genomic DNA was obtained from only 4 of the initial 41 frozen urine samples (10%) for DNA methylation profiling. In comparison, all four buffy coat samples (100%) provided sufficient genomic DNA. Conclusion High quality data can be obtained provided a sufficient yield of genomic DNA is isolated. Despite optimizing various extraction methodologies, the modest amount of genomic DNA derived from urine, may limit the generalisability of this approach for the identification of DNA methylation biomarkers of chronic diabetic kidney disease. PMID:29462136

  19. DNA methylation profiling of genomic DNA isolated from urine in diabetic chronic kidney disease: A pilot study.

    PubMed

    Lecamwasam, Ashani; Sexton-Oates, Alexandra; Carmody, Jake; Ekinci, Elif I; Dwyer, Karen M; Saffery, Richard

    2018-01-01

    To characterise the genomic DNA (gDNA) yield from urine and quality of derived methylation data generated from the widely used Illuminia Infinium MethylationEPIC (HM850K) platform and compare this with buffy coat samples. DNA methylation is the most widely studied epigenetic mark and variations in DNA methylation profile have been implicated in diabetes which affects approximately 415 million people worldwide. QIAamp Viral RNA Mini Kit and QIAamp DNA micro kit were used to extract DNA from frozen and fresh urine samples as well as increasing volumes of fresh urine. Matched buffy coats to the frozen urine were also obtained and DNA was extracted from the buffy coats using the QIAamp DNA Mini Kit. Genomic DNA of greater concentration than 20μg/ml were used for methylation analysis using the HM850K array. Irrespective of extraction technique or the use of fresh versus frozen urine samples, limited genomic DNA was obtained using a starting sample volume of 5ml (0-0.86μg/mL). In order to optimize the yield, we increased starting volumes to 50ml fresh urine, which yielded only 0-9.66μg/mL A different kit, QIAamp DNA Micro Kit, was trialled in six fresh urine samples and ten frozen urine samples with inadequate DNA yields from 0-17.7μg/mL and 0-1.6μg/mL respectively. Sufficient genomic DNA was obtained from only 4 of the initial 41 frozen urine samples (10%) for DNA methylation profiling. In comparison, all four buffy coat samples (100%) provided sufficient genomic DNA. High quality data can be obtained provided a sufficient yield of genomic DNA is isolated. Despite optimizing various extraction methodologies, the modest amount of genomic DNA derived from urine, may limit the generalisability of this approach for the identification of DNA methylation biomarkers of chronic diabetic kidney disease.

  20. Direct Determination of ECD in ECD Kit: A Solid Sample Quantitation Method for Active Pharmaceutical Ingredient in Drug Product

    PubMed Central

    Chao, Ming-Yu; Liu, Kung-Tien; Hsia, Yi-Chih; Liao, Mei-Hsiu; Shen, Lie-Hang

    2011-01-01

    Technetium-99m ethyl cysteinate dimer (Tc-99m-ECD) is an essential imaging agent used in evaluating the regional cerebral blood flow in patients with cerebrovascular diseases. Determination of active pharmaceutical ingredient, that is, L-Cysteine, N, N′-1,2-ethanediylbis-, diethyl ester, dihydrochloride (ECD) in ECD Kit is a relevant requirement for the pharmaceutical quality control in processes of mass fabrication. We here presented a direct solid sample determination method of ECD in ECD Kit without sample dissolution to avoid the rapid degradation of ECD. An elemental analyzer equipped with a nondispersive infrared detector and a calibration curve of coal standard was used for the quantitation of sulfur in ECD Kit. No significant matrix effect was found. The peak area of coal standard against the amount of sulfur was linear over the range of 0.03–0.10 mg, with a correlation coefficient (r) of 0.9993. Method validation parameters were achieved to demonstrate the potential of this method. PMID:21687539

  1. Comparison of the CT OligoGen kit with cobas 4800 assay for detection of Chlamydia trachomatis.

    PubMed

    Parra-Sánchez, Manuel; Marcuello-López, Ana; García-Rey, Silvia; Zakariya-Yousef, Ismail; Sivianes-Valdecantos, Nieves; Sierra-Atienza, Celestina; Bernal-Martínez, Samuel; Pueyo-Rodrígez, Isabel; Martín-Mazuelos, Estrella; Palomares-Folía, José Carlos

    2015-12-01

    A prospective study was designed to assess the performance of the new CT OligoGen kit and the cobas 4800 assay for detection of Chlamydia trachomatis. A set of samples that included urine samples (n=212), endocervical (n=167), rectal (n=53), pharyngeal (n=7) and urethral swabs (n=3). The samples were sent from a regional sexually transmitted diseases (STD) clinic in Seville, Spain, and were collected from 261 men and 181 women. Discordant results were re-analyzed and clinical data and other tests were reviewed in order to resolve them. Sensitivity, specificity, positive predicative value (PPV), negative predictive value (NPV) and kappa value for C. trachomatis detection using the CT OligoGen kit were 98.5%, 100%, 100%, 95.4% and 0.97, respectively. This new kit had a high sensitivity, specificity, PPV and NPV for C. trachomatis, therefore the performance profile confirms the usefulness and reliable results of this new assay. Copyright © 2015 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  2. Mobile chemical detector (AP2C+SP4E) as an aid for medical decision making in the battlefield.

    PubMed

    Eisenkraft, Arik; Markel, Gal; Simovich, Shirley; Layish, Ido; Hoffman, Azik; Finkelstein, Arseny; Rotman, Eran; Dushnitsky, Tsvika; Krivoy, Amir

    2007-09-01

    The combination of the AP2C unit with the SP4E kit composes a lightweight mobile detector of chemical warfare agents (CWA), such as nerve and mustard agents, with both vapor- and liquid-sampling capabilities. This apparatus was recently introduced into our military medical units as an aid for detection of CWA on casualties. Importantly, critical information regarding the applicability in the battlefield was absent. In view of the serious consequences that might follow a proclamation of CWA recognition in battlefield, a high false-positive rate positions the utilization of this apparatus as a medical decision tool in question. We have therefore conducted a field experiment to test the false-positive rate as well as analyze possible factors leading to false-positive readings with this device. The experiment was carried out before and after a 4-day army field exercise, using a standard AP2C device, a SP4E surface sampling kit, and a specially designed medical sampling kit for casualties, intended for medical teams. Soldiers were examined at rest, after mild exercise, and after 4 days in the field. The readings with AP2C alone were compared to the combination of AP2C and SP4E and to the medical sampling kit. Various body fluids served as negative controls. Remarkably, we found a false-positive rate of 57% at rest and after mild exercise, and an even higher rate of 64% after the 4-day field exercise with the AP2C detector alone, as compared to almost no false-positive readings with the combination of AP2C and SP4E. Strikingly, the medical sampling kit has yielded numerous false-positive readings, even in normal body fluids such as blood, urine, and saliva. We therefore see no place for using the medical sampling kit due to an unaccepted high rate of false-positive readings. Finally, we have designed an algorithm that uses the entire apparatus of AP2C and SP4E as a reliable validation tool for medical triage in the setting of exposure to nerve agents in the battlefield.

  3. Improved amplification results following episodes of failure to amplify at the Amelogenin Locus using PowerPlex® ESI 16 Fast System.

    PubMed

    Berlyne, Sigal; Oz, Carla; Einot, Naftaly; Avraham, Shlomit; Ram, Tanya; Goldberg, Miri D; Gafny, Ron

    2017-07-01

    In 2012 the Israel Police DNA Casework laboratory adopted the 16 STR PowerPlex ® ESI kit for routine use. The Promega Company updated this kit and developed the PowerPlex ® ESI 16 Fast System in which all autosomal primer pairs remained identical to the original set, except at the amelogenin site. The master mix was improved and optimized which allowed for direct, faster and more robust amplification. Prior to implementing the PowerPlex ® ESI 16 Fast System in our lab, we conducted a preliminary assay where 213 casework samples were amplified using the new kit. These samples had previously been extracted by one of two extraction kits employed by our lab. (the PrepFiler ExpressTM and PrepFiler BTATM Forensic DNA Extraction Kits). The amplification results from these samples were compared to samples amplified using the original PowerPlex ® ESI 16 kit. Multiple incidents of failure to amplify at the amelogenin locus were noted using the new system with the recommended protocol at a rate of 13% (28 of 213 samples). Experiments were performed to understand whether these amplification failures could be a result of primer binding site mutations, extraction method reagents and/or inhibitors. The conclusions reached following these experiments, in conjunction with consultation with the manufacturer, led to the trial of a modified amplification protocol where the suggested annealing temperature was reduced by 2 degrees. To evaluate the efficiency of this altered protocol, a comparison study was undertaken where 88 additional casework samples were chosen and amplified using both the modified 58°C and the recommended 60°C annealing temperatures. We concluded that the most effective method in our laboratory for achieving a consistent and balanced amplification at the amelogenin locus was to reduce the annealing temperature from the manufacturer's recommended 60°C to 58°C. This modification resulted in a reduction of the failure to amplify at the amelogenin locus from 13% (28/213) to 1.1% (1/88) without any observed changes to the autosomal STR amplification results. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Comparison of DNA extraction methods used to detect bacterial and yeast DNA from spiked whole blood by real-time PCR.

    PubMed

    Dalla-Costa, Libera M; Morello, Luis G; Conte, Danieli; Pereira, Luciane A; Palmeiro, Jussara K; Ambrosio, Altair; Cardozo, Dayane; Krieger, Marco A; Raboni, Sonia M

    2017-09-01

    Sepsis is the leading cause of death in intensive care units (ICUs) worldwide and its diagnosis remains a challenge. Blood culturing is the gold standard technique for blood stream infection (BSI) identification. Molecular tests to detect pathogens in whole blood enable early use of antimicrobials and affect clinical outcomes. Here, using real-time PCR, we evaluated DNA extraction using seven manual and three automated commercially available systems with whole blood samples artificially contaminated with Escherichia coli, Staphylococcus aureus, and Candida albicans, microorganisms commonly associated with BSI. Overall, the commercial kits evaluated presented several technical limitations including long turnaround time and low DNA yield and purity. The performance of the kits was comparable for detection of high microorganism loads (10 6 CFU/mL). However, the detection of lower concentrations was variable, despite the addition of pre-processing treatment to kits without such steps. Of the evaluated kits, the UMD-Universal CE IVD kit generated a higher quantity of DNA with greater nucleic acid purity and afforded the detection of the lowest microbial load in the samples. The inclusion of pre-processing steps with the kit seems to be critical for the detection of microorganism DNA directly from whole blood. In conclusion, future application of molecular techniques will require overcoming major challenges such as the detection of low levels of microorganism nucleic acids amidst the large quantity of human DNA present in samples or differences in the cellular structures of etiological agents that can also prevent high-quality DNA yields. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Synthesis on structure and properties of zinc nanocrystal in high ordered 3D nanostructures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sathyaseelan, B., E-mail: bsseelan03@gmail.com; Manigandan, A.; Anbarasu, V.

    2015-06-24

    The wet impregnation method was employed to prepare ZnO encapsulated in mesoporous silica (ZnO/KIT-6). The prepared ZnO/KIT-6 samples have been studied by X-ray diffraction, transmission electron microscope, and nitrogen adsorption–desorption isotherm. The low angle powder XRD patterns of Calcined ZnO/KIT-6 materials showed a phase that can be indexed to cubic Ia3d. Tem images revealed well ordered cubic 3D nanoporous chennels. The ZnO encapsulated in KIT-6 can be used as light-emitting diodes and ultraviolet nanolasers.

  6. Statistical modeling of dental unit water bacterial test kit performance.

    PubMed

    Cohen, Mark E; Harte, Jennifer A; Stone, Mark E; O'Connor, Karen H; Coen, Michael L; Cullum, Malford E

    2007-01-01

    While it is important to monitor dental water quality, it is unclear whether in-office test kits provide bacterial counts comparable to the gold standard method (R2A). Studies were conducted on specimens with known bacterial concentrations, and from dental units, to evaluate test kit accuracy across a range of bacterial types and loads. Colony forming units (CFU) were counted for samples from each source, using R2A and two types of test kits, and conformity to Poisson distribution expectations was evaluated. Poisson regression was used to test for effects of source and device, and to estimate rate ratios for kits relative to R2A. For all devices, distributions were Poisson for low CFU/mL when only beige-pigmented bacteria were considered. For higher counts, R2A remained Poisson, but kits exhibited over-dispersion. Both kits undercounted relative to R2A, but the degree of undercounting was reasonably stable. Kits did not grow pink-pigmented bacteria from dental-unit water identified as Methylobacterium rhodesianum. Only one of the test kits provided results with adequate reliability at higher bacterial concentrations. Undercount bias could be estimated for this device and used to adjust test kit results. Insensitivity to methylobacteria spp. is problematic.

  7. A cluster randomized trial of strategies to increase uptake amongst young women invited for their first cervical screen: The STRATEGIC trial.

    PubMed

    Kitchener, H; Gittins, M; Cruickshank, M; Moseley, C; Fletcher, S; Albrow, R; Gray, A; Brabin, L; Torgerson, D; Crosbie, E J; Sargent, A; Roberts, C

    2018-06-01

    Objectives To measure the feasibility and effectiveness of interventions to increase cervical screening uptake amongst young women. Methods A two-phase cluster randomized trial conducted in general practices in the NHS Cervical Screening Programme. In Phase 1, women in practices randomized to intervention due for their first invitation to cervical screening received a pre-invitation leaflet and, separately, access to online booking. In Phase 2, non-attenders at six months were randomized to one of: vaginal self-sample kits sent unrequested or offered; timed appointments; nurse navigator; or the choice between nurse navigator or self-sample kits. Primary outcome was uplift in intervention vs. control practices, at 3 and 12 months post invitation. Results Phase 1 randomized 20,879 women. Neither pre-invitation leaflet nor online booking increased screening uptake by three months (18.8% pre-invitation leaflet vs. 19.2% control and 17.8% online booking vs. 17.2% control). Uptake was higher amongst human papillomavirus vaccinees at three months (OR 2.07, 95% CI 1.69-2.53, p < 0.001). Phase 2 randomized 10,126 non-attenders, with 32-34 clusters for each intervention and 100 clusters as controls. Sending self-sample kits increased uptake at 12 months (OR 1.51, 95% CI 1.20-1.91, p = 0.001), as did timed appointments (OR 1.41, 95% CI 1.14-1.74, p = 0.001). The offer of a nurse navigator, a self-sample kits on request, and choice between timed appointments and nurse navigator were ineffective. Conclusions Amongst non-attenders, self-sample kits sent and timed appointments achieved an uplift in screening over the short term; longer term impact is less certain. Prior human papillomavirus vaccination was associated with increased screening uptake.

  8. Detection of enterotoxigenic Clostridium perfringens in meat samples by using molecular methods.

    PubMed

    Kaneko, Ikuko; Miyamoto, Kazuaki; Mimura, Kanako; Yumine, Natsuko; Utsunomiya, Hirotoshi; Akimoto, Shigeru; McClane, Bruce A

    2011-11-01

    To prevent food-borne bacterial diseases and to trace bacterial contamination events to foods, microbial source tracking (MST) methods provide important epidemiological information. To apply molecular methods to MST, it is necessary not only to amplify bacterial cells to detection limit levels but also to prepare DNA with reduced inhibitory compounds and contamination. Isolates carrying the Clostridium perfringens enterotoxin gene (cpe) on the chromosome or a plasmid rank among the most important food-borne pathogens. Previous surveys indicated that cpe-positive C. perfringens isolates are present in only ∼5% of nonoutbreak food samples and then only at low numbers, usually less than 3 cells/g. In this study, four molecular assays for the detection of cpe-positive C. perfringens isolates, i.e., ordinary PCR, nested PCR, real-time PCR, and loop-mediated isothermal amplification (LAMP), were developed and evaluated for their reliability using purified DNA. For use in the artificial contamination of meat samples, DNA templates were prepared by three different commercial DNA preparation kits. The four molecular assays always detected cpe when >10³ cells/g of cpe-positive C. perfringens were present, using any kit. Of three tested commercial DNA preparation kits, the InstaGene matrix kit appeared to be most suitable for the testing of a large number of samples. By using the InstaGene matrix kit, the four molecular assays efficiently detected cpe using DNA prepared from enrichment culture specimens of meat samples contaminated with low numbers of cpe-positive C. perfringens vegetative cells or spores. Overall, the current study developed molecular assay protocols for MST to detect the contamination of foods with low numbers of cells, and at a low frequency, of cpe-positive C. perfringens isolates.

  9. Comparison of commercial exosome isolation kits for circulating exosomal microRNA profiling.

    PubMed

    Ding, Meng; Wang, Cheng; Lu, Xiaolan; Zhang, Cuiping; Zhou, Zhen; Chen, Xi; Zhang, Chen-Yu; Zen, Ke; Zhang, Chunni

    2018-06-01

    Circulating exosomal microRNAs (miRNAs) are valuable biomarker candidates; however, information on the characterization and mutual agreement of commercial kits for circulating exosomal miRNA profiling is scarce. Here, we analyzed the advantages and weaknesses of four commonly used commercial kits for exosomal miRNA profiling and their application to the sample of serum and/or plasma, respectively. NanoSight and Western blotting were conducted to evaluate the efficiency and purity of the isolated exosomes. In our conditions, the size distribution of the isolated particles was appropriate (40-150 nm), and ExoQuick™ Exosome Precipitation Solution (EXQ) generated a relatively high yield of exosomes. Nevertheless, albumin impurity was ubiquitous for all the four kits, and Total Exosome Isolation for serum or plasma (TEI) yielded a relatively pure isolation. We further performed Illumina sequencing combined with RT-qPCR to determine the ability of these kits for miRNA profiling. There was significant correlation of the exosomal miRNA profile and specific miRNAs between kits, but with differences depending on methods. exoRNeasy Serum/Plasma Midi Kit (EXR) and EXQ performed better in the specific exosomal miRNAs recovery. Intraassay CVs for specific miRNA measurement were 0.88-3.82, 1.19-3.77, 0-2.70, and 1.23-9.11% for EXR, TEI, EXQ, and RIBO™ Exosome Isolation Reagent (REI), respectively. In each kit, serum yielded a higher abundance of exosomes and exosomal miRNAs than plasma, yet with more albumin impurity. In conclusion, our data provide some valuable guidance for the methodology of disease biomarker identification of circulation exosomal miRNAs. Graphical abstract Circulating exosomal microRNAs (miRNAs) are valuable biomarker candidates; however, information on the characterization and mutual agreement of commercial kits for circulating exosomal miRNA profiling is scarce. In this study, we compared four commonly used commercially available kits for exosomal miRNAsextraction and analyzed the advantages and weaknesses of each kit and their application to the sample ofserum and/or plasma.

  10. An evaluation of direct PCR amplification

    PubMed Central

    Hall, Daniel E.; Roy, Reena

    2014-01-01

    Aim To generate complete DNA profiles from blood and saliva samples deposited on FTA® and non-FTA® paper substrates following a direct amplification protocol. Methods Saliva samples from living donors and blood samples from deceased individuals were deposited on ten different FTA® and non-FTA® substrates. These ten paper substrates containing body fluids were kept at room temperature for varying lengths of time ranging from one day to approximately one year. For all assays in this research, 1.2 mm punches were collected from each substrate containing one type of body fluid and amplified with reagents provided in the nine commercial polymerase chain reaction (PCR) amplification kits. The substrates were not subjected to purification reagent or extraction buffer prior to amplification. Results Success rates were calculated for all nine amplification kits and all ten substrates based on their ability to yield complete DNA profiles following a direct amplification protocol. Six out of the nine amplification kits, and four out of the ten paper substrates had the highest success rates overall. Conclusion The data show that it is possible to generate complete DNA profiles following a direct amplification protocol using both standard (non-direct) and direct PCR amplification kits. The generation of complete DNA profiles appears to depend more on the success of the amplification kit rather than the than the FTA®- or non-FTA®-based substrates. PMID:25559837

  11. Comparison of Three Different Commercial Kits for the Human Papilloma Virus Genotyping.

    PubMed

    Lim, Yong Kwan; Choi, Jee-Hye; Park, Serah; Kweon, Oh Joo; Park, Ae Ja

    2016-11-01

    High-risk type human papilloma virus (HPV) is the most important cause of cervical cancer. Recently, real-time polymerase chain reaction and reverse blot hybridization assay-based HPV DNA genotyping kits are developed. So, we compared the performances of different three HPV genotyping kits using different analytical principles and methods. Two hundred positive and 100 negative cervical swab specimens were used. DNA was extracted and all samples were tested by the MolecuTech REBA HPV-ID, Anyplex II HPV28 Detection, and HPVDNAChip. Direct sequencing was performed as a reference method for confirming high-risk HPV genotypes 16, 18, 45, 52, and 58. Although high-level agreement results were observed in negative samples, three kits showed decreased interassay agreement as screening setting in positive samples. Comparing the genotyping results, three assays showed acceptable sensitivity and specificity for the detection of HPV 16 and 18. Otherwise, various sensitivities showed in the detection of HPV 45, 52, and 58. The three assays had dissimilar performance of HPV screening capacity and exhibited moderate level of concordance in HPV genotyping. These discrepant results were unavoidable due to difference in type-specific analytical sensitivity and lack of standardization; therefore, we suggested that the efforts to standardization of HPV genotyping kits and adjusting analytical sensitivity would be important for the best clinical performance. © 2016 Wiley Periodicals, Inc.

  12. Evaluation of a newly developed quantitative heart-type fatty acid binding protein assay based on fluorescence immunochromatography using specific monoclonal antibodies.

    PubMed

    Kang, Keren; Wu, Peidian; Li, Wenmei; Tang, Shixing; Wang, Jihua; Luo, Xiaochun; Xie, Mingquan

    2015-01-01

    To develop a rapid, sensitive and specific assay for quantification of serum heart-type fatty acid binding protein (H-FABP) based on immunofluorescence of specific monoclonal antibodies. We generated novel H-FABP-directed monoclonal antibodies by cloning of spleen cells of mice immunized with H-FABP. Epitopes were mapped and antigen affinity was assessed by surface plasmon resonance (SPR). The H-FABP specific monoclonal antibodies were coupled to fluorescent beads and sprayed onto a nitrocellulose membrane facilitating quantification of H-FABP by immunofluorescence. Reagent cross-reactivity, interference resistance, accuracy and sensitivity were examined. A total of 103 clinical samples were used to compare the sensitivity and specificity of the new assay to a commercially available Randox kit. This new assay could be finished within 15 min, with sensitivity reaching 1 ng/ml. In a trial of 103 clinical serum samples, the new testing kit results were highly correlated with those from the Randox kit (R(2) = 0.9707). Using the Randox kit as the reference kit, the sensitivity of the new assay was 98.25%, and specificity was 100%. An immunofluorescence-based H-FABP assay employing novel monoclonal antibodies could rapidly, specifically and sensitively detect H-FABP in serum samples, providing an effective method for rapid clinical assessment of H-FABP index in the clinic.

  13. Optimisation of high-quality total ribonucleic acid isolation from cartilaginous tissues for real-time polymerase chain reaction analysis.

    PubMed

    Peeters, M; Huang, C L; Vonk, L A; Lu, Z F; Bank, R A; Helder, M N; Doulabi, B Zandieh

    2016-11-01

    Studies which consider the molecular mechanisms of degeneration and regeneration of cartilaginous tissues are seriously hampered by problematic ribonucleic acid (RNA) isolations due to low cell density and the dense, proteoglycan-rich extracellular matrix of cartilage. Proteoglycans tend to co-purify with RNA, they can absorb the full spectrum of UV light and they are potent inhibitors of polymerase chain reaction (PCR). Therefore, the objective of the present study is to compare and optimise different homogenisation methods and RNA isolation kits for an array of cartilaginous tissues. Tissue samples such as the nucleus pulposus (NP), annulus fibrosus (AF), articular cartilage (AC) and meniscus, were collected from goats and homogenised by either the MagNA Lyser or Freezer Mill. RNA of duplicate samples was subsequently isolated by either TRIzol (benchmark), or the RNeasy Lipid Tissue, RNeasy Fibrous Tissue, or Aurum Total RNA Fatty and Fibrous Tissue kits. RNA yield, purity, and integrity were determined and gene expression levels of type II collagen and aggrecan were measured by real-time PCR. No differences between the two homogenisation methods were found. RNA isolation using the RNeasy Fibrous and Lipid kits resulted in the purest RNA (A260/A280 ratio), whereas TRIzol isolations resulted in RNA that is not as pure, and show a larger difference in gene expression of duplicate samples compared with both RNeasy kits. The Aurum kit showed low reproducibility. For the extraction of high-quality RNA from cartilaginous structures, we suggest homogenisation of the samples by the MagNA Lyser. For AC, NP and AF we recommend the RNeasy Fibrous kit, whereas for the meniscus the RNeasy Lipid kit is advised.Cite this article: M. Peeters, C. L. Huang, L. A. Vonk, Z. F. Lu, R. A. Bank, M. N. Helder, B. Zandieh Doulabi. Optimisation of high-quality total ribonucleic acid isolation from cartilaginous tissues for real-time polymerase chain reaction analysis. Bone Joint Res 2016;5:560-568. DOI: 10.1302/2046-3758.511.BJR-2016-0033.R3. © 2016 Peeters et al.

  14. Optimisation of high-quality total ribonucleic acid isolation from cartilaginous tissues for real-time polymerase chain reaction analysis

    PubMed Central

    Peeters, M.; Huang, C. L.; Vonk, L. A.; Lu, Z. F.; Bank, R. A.; Doulabi, B. Zandieh

    2016-01-01

    Objectives Studies which consider the molecular mechanisms of degeneration and regeneration of cartilaginous tissues are seriously hampered by problematic ribonucleic acid (RNA) isolations due to low cell density and the dense, proteoglycan-rich extracellular matrix of cartilage. Proteoglycans tend to co-purify with RNA, they can absorb the full spectrum of UV light and they are potent inhibitors of polymerase chain reaction (PCR). Therefore, the objective of the present study is to compare and optimise different homogenisation methods and RNA isolation kits for an array of cartilaginous tissues. Materials and Methods Tissue samples such as the nucleus pulposus (NP), annulus fibrosus (AF), articular cartilage (AC) and meniscus, were collected from goats and homogenised by either the MagNA Lyser or Freezer Mill. RNA of duplicate samples was subsequently isolated by either TRIzol (benchmark), or the RNeasy Lipid Tissue, RNeasy Fibrous Tissue, or Aurum Total RNA Fatty and Fibrous Tissue kits. RNA yield, purity, and integrity were determined and gene expression levels of type II collagen and aggrecan were measured by real-time PCR. Results No differences between the two homogenisation methods were found. RNA isolation using the RNeasy Fibrous and Lipid kits resulted in the purest RNA (A260/A280 ratio), whereas TRIzol isolations resulted in RNA that is not as pure, and show a larger difference in gene expression of duplicate samples compared with both RNeasy kits. The Aurum kit showed low reproducibility. Conclusion For the extraction of high-quality RNA from cartilaginous structures, we suggest homogenisation of the samples by the MagNA Lyser. For AC, NP and AF we recommend the RNeasy Fibrous kit, whereas for the meniscus the RNeasy Lipid kit is advised. Cite this article: M. Peeters, C. L. Huang, L. A. Vonk, Z. F. Lu, R. A. Bank, M. N. Helder, B. Zandieh Doulabi. Optimisation of high-quality total ribonucleic acid isolation from cartilaginous tissues for real-time polymerase chain reaction analysis. Bone Joint Res 2016;5:560–568. DOI: 10.1302/2046-3758.511.BJR-2016-0033.R3. PMID:27881439

  15. Development and performance evaluation of a novel immunofluorescence chromatographic assay for histidine-rich protein 2 of Plasmodium falciparum.

    PubMed

    Kang, Keren; Dzakah, Emmanuel E; Huang, Yongping; Xie, Mingquan; Luo, Xiaochun; Li, Wenmei; Wang, Jihua

    2015-05-30

    The low sensitivity and specificity of Plasmodium falciparum diagnostic tests pose a serious health threat to people living in endemic areas. The objective of the study was to develop a rapid assay for the detection of histidine-rich protein 2 (HRP2) of P. falciparum in whole blood by immunofluorescence chromatographic technology. A total of 1163 positive and negative blood samples were screened. The double-antibody sandwich assay was used to establish the kit and its performance was evaluated for sensitivity, specificity, accuracy, precision, stability, and clinical effectiveness. The cut-off level of detection of the kit was 25 parasites/μl. Common interfering substances in human blood specimens, such as bilirubin, triglyceride and cholesterol had no significant effect on HRP2 antigen detection. The precision of the kit was run with different concentration of standard calibrators and the values were less than 10 %. The performance of this diagnostic kit in the detection of the calibrators has shown that a shelf life of about 12 months gives a more reliable result. Among clinical samples tested, the HRP2 test kit and the reference products had good coincidence rate in a parallel experiment and this test kit had a more sensitive detecting level to the target protein than the reference kits used in this study. The specificity and sensitivity for this test were 99.6 % (800/803) and 99.7 % (1160/1163), respectively. A novel HRP2 immunofluorescence detection method was developed in this study. Overall performance evaluation indicated that the kit has a rapid, high sensitivity and on-spot method for detecting P. falciparum.

  16. Food and medical sample freezer kit concept for Shuttle

    NASA Technical Reports Server (NTRS)

    Copeland, R. J.; Jaax, J. R.; Proctor, B. W.

    1977-01-01

    A variety of food and storage of samples can be provided by a Space Shuttle Orbiter Freezer Kit. The proposed concept is an integrated package consisting of four -23 C (-10 F) storage compartments and a Stirling cycle refrigeration unit. The Stirling cycle mechanical refrigeration was selected over alternative systems for superior efficiency and safety. The trade-offs and a conceptual design of the system are presented.

  17. Laboratory diagnosis of amebiasis in a sample of students from southeastern Brazil and a comparison of microscopy with enzyme-linked immunosorbent assay for screening of infections with Entamoeba sp.

    PubMed

    Pereira, Valeriana Valadares; Conceição, Abiqueila da Silva; Maximiano, Leandro Henrique Silva; Belligoli, Leonardo de Queiroz Gomes; Silva, Eduardo Sergio da

    2014-01-01

    Epidemiological studies on amebiasis have been reassessed since Entamoeba histolytica and E. dispar were first recognized as distinct species. Because the morphological similarity of these species renders microscopic diagnosis unreliable, additional tools are required to discriminate between Entamoeba species. The objectives of our study were to compare microscopy with ELISA kit (IVD®) results, to diagnose E. histolytica infection, and to determine the prevalence of amebiasis in a sample of students from southeastern Brazil. In this study, diagnosis was based on microscopy due to its capacity for revealing potential cysts/trophozoites and on two commercial kits for antigen detection in stool samples. For 1,403 samples collected from students aged 6 to 14 years who were living in Divinópolis, Minas Gerais, Brazil, microscopy underestimated the number of individuals infected with E. histolytica/E. dispar (5.7% prevalence) compared with the ELISA kit (IVD®)-based diagnoses (15.7% for E. histolytica/E. dispar). A comparison of the ELISA (IVD®) and light microscopy results returned a 20% sensitivity, 97% specificity, low positive predictive value, and high negative predictive value for microscopy. An ELISA kit (TechLab®) that was specific for E. histolytica detected a 3.1% (43/1403) prevalence for E. histolytica infection. The ELISA kit (IVD®) can be used as an alternative screening tool. The high prevalence of E. histolytica infection detected in this study warrants the implementation of actions directed toward health promotion and preventive measures.

  18. Immunoaffinity based methods are superior to kits for purification of prostate derived extracellular vesicles from plasma samples.

    PubMed

    Brett, Sabine I; Lucien, Fabrice; Guo, Charles; Williams, Karla C; Kim, Yohan; Durfee, Paul N; Brinker, C J; Chin, Joseph I; Yang, Jun; Leong, Hon S

    2017-05-01

    The ability to isolate extracellular vesicles (EVs) such as exosomes or microparticles is an important method that is currently not standardized. While commercially available kits offer purification of EVs from biofluids, such purified EV samples will also contain non-EV entities such as soluble protein and nucleic acids that could confound subsequent experimentation. Ideally, only EVs would be isolated and no soluble protein would be present in the final EV preparation. We compared commercially available EV isolation kits with immunoaffinity purification techniques and evaluated our final EV preparations using atomic force microscopy (AFM) and nanoscale flow cytometry (NFC). AFM is the only modality capable of detecting distinguishing soluble protein from EVs which is important for downstream proteomics approaches. NFC is the only technique capable of quantitating the proportion of target EVs to non-target EVs in the final EV preparation. To determine enrichment of prostate derived EVs relative to non-target MPs, anti-PSMA (Prostate Specific Membrane Antigen) antibodies were used in NFC. Antibody-based immunoaffinity purification generated the highest quality of prostate derived EV preparations due to the lack of protein and RNA present in the samples. All kits produced poor purity EV preparations that failed to deplete the sample of plasma protein. While attractive due to their ease of use, EV purification kits do not provide substantial improvements in isolation of EVs from biofluids such as plasma. Immunoaffinity approaches are more efficient and economical and will also eliminate a significant portion of plasma proteins which is necessary for downstream approaches. © 2017 Wiley Periodicals, Inc.

  19. Automated extraction of DNA from biological stains on fabric from crime cases. A comparison of a manual and three automated methods.

    PubMed

    Stangegaard, Michael; Hjort, Benjamin B; Hansen, Thomas N; Hoflund, Anders; Mogensen, Helle S; Hansen, Anders J; Morling, Niels

    2013-05-01

    The presence of PCR inhibitors in extracted DNA may interfere with the subsequent quantification and short tandem repeat (STR) reactions used in forensic genetic DNA typing. DNA extraction from fabric for forensic genetic purposes may be challenging due to the occasional presence of PCR inhibitors that may be co-extracted with the DNA. Using 120 forensic trace evidence samples consisting of various types of fabric, we compared three automated DNA extraction methods based on magnetic beads (PrepFiler Express Forensic DNA Extraction Kit on an AutoMate Express, QIAsyphony DNA Investigator kit either with the sample pre-treatment recommended by Qiagen or an in-house optimized sample pre-treatment on a QIAsymphony SP) and one manual method (Chelex) with the aim of reducing the amount of PCR inhibitors in the DNA extracts and increasing the proportion of reportable STR-profiles. A total of 480 samples were processed. The highest DNA recovery was obtained with the PrepFiler Express kit on an AutoMate Express while the lowest DNA recovery was obtained using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen. Extraction using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen resulted in the lowest percentage of PCR inhibition (0%) while extraction using manual Chelex resulted in the highest percentage of PCR inhibition (51%). The largest number of reportable STR-profiles was obtained with DNA from samples extracted with the PrepFiler Express kit (75%) while the lowest number was obtained with DNA from samples extracted using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen (41%). Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. DEMONSTRATION BULLETIN: ENVIROGARD™ PCB TEST KIT - MILLIPORE, INC.

    EPA Science Inventory

    The EnviroGard™ polychlorinated biphenyl (PCB) immunoassay test kit rapidly analyzes for PCB concentrations in soils. Soil sample extracts are added to test tubes coated with antibodies that bind PCB molecules. The excess soil extracts are washed out of the tubes after incubat...

  1. Quantitation of next generation sequencing library preparation protocol efficiencies using droplet digital PCR assays - a systematic comparison of DNA library preparation kits for Illumina sequencing.

    PubMed

    Aigrain, Louise; Gu, Yong; Quail, Michael A

    2016-06-13

    The emergence of next-generation sequencing (NGS) technologies in the past decade has allowed the democratization of DNA sequencing both in terms of price per sequenced bases and ease to produce DNA libraries. When it comes to preparing DNA sequencing libraries for Illumina, the current market leader, a plethora of kits are available and it can be difficult for the users to determine which kit is the most appropriate and efficient for their applications; the main concerns being not only cost but also minimal bias, yield and time efficiency. We compared 9 commercially available library preparation kits in a systematic manner using the same DNA sample by probing the amount of DNA remaining after each protocol steps using a new droplet digital PCR (ddPCR) assay. This method allows the precise quantification of fragments bearing either adaptors or P5/P7 sequences on both ends just after ligation or PCR enrichment. We also investigated the potential influence of DNA input and DNA fragment size on the final library preparation efficiency. The overall library preparations efficiencies of the libraries show important variations between the different kits with the ones combining several steps into a single one exhibiting some final yields 4 to 7 times higher than the other kits. Detailed ddPCR data also reveal that the adaptor ligation yield itself varies by more than a factor of 10 between kits, certain ligation efficiencies being so low that it could impair the original library complexity and impoverish the sequencing results. When a PCR enrichment step is necessary, lower adaptor-ligated DNA inputs leads to greater amplification yields, hiding the latent disparity between kits. We describe a ddPCR assay that allows us to probe the efficiency of the most critical step in the library preparation, ligation, and to draw conclusion on which kits is more likely to preserve the sample heterogeneity and reduce the need of amplification.

  2. Evaluation of a culture-based pathogen identification kit for bacterial causes of bovine mastitis.

    PubMed

    Viora, L; Graham, E M; Mellor, D J; Reynolds, K; Simoes, P B A; Geraghty, T E

    2014-07-26

    Accurate identification of mastitis-causing bacteria supports effective management and can be used to implement selective use of antimicrobials for treatment. The objectives of this study were to compare the results from a culture-based mastitis pathogen detection test kit ('VetoRapid', Vétoquinol) with standard laboratory culture and to evaluate the potential suitability of the test kit to inform a selective treatment programme. Overall 231 quarter milk samples from five UK dairy farms were collected. The sensitivity and specificity of the test kit for the identification of Escherichia coli, Staphylococcus aureus, coagulase-negative staphylococci, Streptococcus uberis and Enterococcus spp. ranged from 17 per cent to 84 per cent and 92 per cent to 98 per cent, respectively. In total, 23 of 68 clinical samples were assigned as meeting the requirement for antimicrobial treatment (Gram-positive organism cultured) according to standard culture results, with the test kit results having sensitivity and specificity of 91 per cent and 78 per cent, respectively. Several occurrences of misidentification are reported, including S. aureus being misidentified as coagulase-negative staphylococci and vice versa. The test kit provides rapid preliminary identification of five common causes of bovine mastitis under UK field conditions and is likely to be suitable for informing selective treatment of clinical mastitis caused by Gram-positive organisms. British Veterinary Association.

  3. Advanced forensic validation for human spermatozoa identification using SPERM HY-LITER™ Express with quantitative image analysis.

    PubMed

    Takamura, Ayari; Watanabe, Ken; Akutsu, Tomoko

    2017-07-01

    Identification of human semen is indispensable for the investigation of sexual assaults. Fluorescence staining methods using commercial kits, such as the series of SPERM HY-LITER™ kits, have been useful to detect human sperm via strong fluorescence. These kits have been examined from various forensic aspects. However, because of a lack of evaluation methods, these studies did not provide objective, or quantitative, descriptions of the results nor clear criteria for the decisions reached. In addition, the variety of validations was considerably limited. In this study, we conducted more advanced validations of SPERM HY-LITER™ Express using our established image analysis method. Use of this method enabled objective and specific identification of fluorescent sperm's spots and quantitative comparisons of the sperm detection performance under complex experimental conditions. For body fluid mixtures, we examined interference with the fluorescence staining from other body fluid components. Effects of sample decomposition were simulated in high humidity and high temperature conditions. Semen with quite low sperm concentrations, such as azoospermia and oligospermia samples, represented the most challenging cases in application of the kit. Finally, the tolerance of the kit against various acidic and basic environments was analyzed. The validations herein provide useful information for the practical applications of the SPERM HY-LITER™ Express kit, which were previously unobtainable. Moreover, the versatility of our image analysis method toward various complex cases was demonstrated.

  4. LAMP kit for diagnosis of non-falciparum malaria in Plasmodium ovale infected patients.

    PubMed

    Cuadros, Juan; Martin Ramírez, Alexandra; González, Iveth J; Ding, Xavier C; Perez Tanoira, Ramon; Rojo-Marcos, Gerardo; Gómez-Herruz, Peña; Rubio, Jose Miguel

    2017-01-07

    Microscopy and rapid diagnosis tests have a limited sensitivity in diagnosis of malaria by Plasmodium ovale. The LAMP kit (LoopAMP®) can be used in the field without special equipment and could have an important role in malaria control programmes in endemic areas and for malaria diagnosis in returned travellers. The performance of the Pan primer of the kit in detecting malaria by P. ovale was compared with the results of standard nPCR in samples of patients returning from P. ovale endemic areas. Plasmodium ovale positive samples (29, tested by PCR and/or microscopy) and malaria negative specimens (398, tested by microscopy and PCR) were collected in different hospitals of Europe from June 2014 to March 2016 and frozen at -20 °C. Boil and spin method was used to extract DNA from all samples and amplification was performed with LoopAMP® MALARIA kit (Eiken Chemical, Japan) in an automated turbidimeter (Eiken 500). The results of LAMP read by turbidimetry and with the naked eye were compared. The kit showed a sensitivity of 100% and a specificity of 97.24% with positive and negative predictive values of 72.5 and 100%, respectively. Naked eyed readings were in accordance with turbidimetry readings (sensitivity, 92.5%, specificity, 98.96% and positive and negative predictive values, respectively, 90.24 and 99.22%). The limit of detection of LAMP assay for P. ovale was between 0.8 and 2 parasites/µl. The Pan primer of the Malaria kit LoopAMP® can detect P. ovale at very low-levels and showed a predictive negative value of 100%. This tool can be useful in malaria control and elimination programmes and in returned travellers from P. ovale endemic areas. Naked eye readings are equivalent to automated turbidimeter readings in specimens obtained with EDTA.

  5. Developing Save Your Food Kit (Sayofu Kit) to Support Inquiry, Improve Student Learning Outcomes at SMP Plus Hidayatul Mubtadiin and Public Awareness on Food Additives

    NASA Astrophysics Data System (ADS)

    Astutik, J.

    2017-02-01

    Food additives are materials that can not be separated from the lives of students and the community. Based on the preliminary questionnaire, it indicates the lack of kit supporting material additives in some schools and communities. The research objectives of this development are (1) to develop Kit experiment (SAYOFU KIT) and supplementary books to improve student learning outcomes in the classroom and public awareness on food additives (2) to describe the feasibility and potential effectiveness of SAYOFU KIT developed (3) to analyze the practice of SAYOFU KIT and benefits for students and the community. This development study uses 4-D models Thiagarajan, et al (1974). Through some stages, they are: defining, designing, developing and disseminating which involes the students and community. The developed SAYOFU KIT includes additives sample kit, borax test kit, curcumin test kit, formaldehyde test kit, modification heater to the identification of dyes and dye test paper. The study is conducted at SMP Plus Hidayatul Mubtadiin, and TKIT Al Uswah. The products are validated by experts and education practitioners. Qualitative data processing uses descriptive method, whereas quantitative data by using the N-gain. The average yield of expert validation of SAYOFU KIT with supplementary books 76.50% teacher’s book and 76.30% student’s book are eligible. The average yield of 96.81% validation of educational practitioners criteria, piloting a small group of 83.15%, and 82.89% field trials are very decent. The average yield on the student questionnaire responses SAYOFU kit and supplementary book is 87.6% with the criteria very well worth it. N-Gain 0:56 cognitive achievement with the criteria enough. The results of the public poll showed 95% feel the benefits SAYOFU kits for testing food. Based from description indicates that SAYOFU Kit developed feasible, practical, useful to support inquiry learning and improve student learning outcomes as well as public awareness of food additives.

  6. Mast cells and matrix metalloproteinase 9 expression in actinic cheilitis and lip squamous cell carcinoma.

    PubMed

    Souza Freitas, Valéria; de Andrade Santos, Pedro Paulo; de Almeida Freitas, Roseana; Pereira Pinto, Leão; de Souza, Lélia Batista

    2011-09-01

    The aim of this study was to evaluate mast cell (MC) density and migration and their association with matrix metalloproteinase (MMP) 9 expression in squamous cell carcinoma (SCC) and actinic cheilitis (AC). Tryptase, c-Kit, and MMP-9 expression was evaluated in 20 cases of SCC, 20 cases of AC, and 7 cases of normal lip (control samples) by immunohistochemistry techniques. Tryptase(+) and c-Kit(+) MC densities were significantly higher in SCCs than in ACs and control samples (P < .001). However, no significant difference was found when comparing tryptase(+) and c-Kit(+) MC densities between ACs and control samples (P values .185 and .516, respectively). MMP-9 was strongly expressed in SCCs and moderately expressed in ACs and control samples. A highly significant association was found between tryptase(+) MC density and the expression of MMP-9 (P < .001). The increase in MC density associated with the strong expression of MMP-9 may favor SCC progression. Copyright © 2011 Mosby, Inc. All rights reserved.

  7. [Development of a SPA-ELISA method for detecting anti-coronavirus IgG antibodies in serum samples from fulvous fruit bats].

    PubMed

    Zhou, Jie; Liao, Yu-xue; Chen, Zhong; Li, Yu-chun; Gao, Lu-Lu; Chen, Yi-xiong; Cai, Lian-gong; Chen, Qing; Yu, Shou-yi

    2008-05-01

    To develop an simple and sensitive method for detecting anti-coronavirus IgG antibodies in bat sera based on enzyme-linked immunosorbent assay (ELISA). A commercial ELISA kit for detecting SARS-CoV antibody was modified for detecting coronavirus antibodies in bat serum samples. The second antibody in the kit was replaced with horseradish peroxidase-conjugated protein-A (HRP-SPA) based on the characteristics of binding between Staphylococcus aureus protein A (SPA) and mammal IgG Fc fragment. The sera of 55 fulvous fruit bats (Rousettus dasymallus) were tested using the SPA-ELISA. The test results of the positive and negative controls in the kit and the serum samples from convalescent ;patient were consistent with expectation. Coronavirus antibody was detected in 2 out of the 55 bat serum samples. Serum neutralization test confirmed the validity of the SPA-ELISA method. This SPA-ELISA method is applicable for detecting coronavirus antibody in bat sera.

  8. Analysis of Platelet-Rich Plasma Extraction

    PubMed Central

    Fitzpatrick, Jane; Bulsara, Max K.; McCrory, Paul Robert; Richardson, Martin D.; Zheng, Ming Hao

    2017-01-01

    Background: Platelet-rich plasma (PRP) has been extensively used as a treatment in tissue healing in tendinopathy, muscle injury, and osteoarthritis. However, there is variation in methods of extraction, and this produces different types of PRP. Purpose: To determine the composition of PRP obtained from 4 commercial separation kits, which would allow assessment of current classification systems used in cross-study comparisons. Study Design: Controlled laboratory study. Methods: Three normal adults each donated 181 mL of whole blood, some of which served as a control and the remainder of which was processed through 4 PRP separation kits: GPS III (Biomet Biologics), Smart-Prep2 (Harvest Terumo), Magellan (Arteriocyte Medical Systems), and ACP (Device Technologies). The resultant PRP was tested for platelet count, red blood cell count, and white blood cell count, including differential in a commercial pathology laboratory. Glucose and pH measurements were obtained from a blood gas autoanalyzer machine. Results: Three kits taking samples from the “buffy coat layer” were found to have greater concentrations of platelets (3-6 times baseline), while 1 kit taking samples from plasma was found to have platelet concentrations of only 1.5 times baseline. The same 3 kits produced an increased concentration of white blood cells (3-6 times baseline); these consisted of neutrophils, leukocytes, and monocytes. This represents high concentrations of platelets and white blood cells. A small drop in pH was thought to relate to the citrate used in the sample preparation. Interestingly, an unexpected increase in glucose concentrations, with 3 to 6 times greater than baseline levels, was found in all samples. Conclusion: This study reveals the variation of blood components, including platelets, red blood cells, leukocytes, pH, and glucose in PRP extractions. The high concentrations of cells are important, as the white blood cell count in PRP samples has frequently been ignored, being considered insignificant. The lack of standardization of PRP preparation for clinical use has contributed at least in part to the varying clinical efficacy in PRP use. Clinical Relevance: The variation of platelet and other blood component concentrations between commercial PRP kits may affect clinical treatment outcomes. There is a need for standardization of PRP for clinical use. PMID:28210651

  9. Development of a quantitative validation method for forensic investigation of human spermatozoa using a commercial fluorescence staining kit (SPERM HY-LITER™ Express).

    PubMed

    Takamura, Ayari; Watanabe, Ken; Akutsu, Tomoko

    2016-11-01

    In investigations of sexual assaults, as well as in identifying a suspect, the detection of human sperm is important. Recently, a kit for fluorescent staining of human spermatozoa, SPERM HY-LITER™, has become available. This kit allows for microscopic observation of the heads of human sperm using an antibody tagged with a fluorescent dye. This kit is specific to human sperm and provides easy detection by luminescence. However, criteria need to be established to objectively evaluate the fluorescent signals and to evaluate the staining efficiency of this kit. These criteria will be indispensable for investigation of forensic samples. In the present study, the SPERM HY-LITER™ Express kit, which is an improved version of SPERM HY-LITER™, was evaluated using an image analysis procedure using Laplacian and Gaussian methods. This method could be used to automatically select important regions of fluorescence produced by sperm. The fluorescence staining performance was evaluated and compared under various experimental conditions, such as for aged traces and in combination with other chemical staining methods. The morphological characteristics of human sperm were incorporated into the criteria for objective identification of sperm, based on quantified features of the fluorescent spots. Using the criteria, non-specific or insignificant fluorescent spots were excluded, and the specificity of the kit for human sperm was confirmed. The image analysis method and criteria established in this study are universal and could be applied under any experimental conditions. These criteria will increase the reliability of operator judgment in the analysis of human sperm samples in forensics.

  10. Mutational status of EGFR and KIT in thymoma and thymic carcinoma.

    PubMed

    Yoh, Kiyotaka; Nishiwaki, Yutaka; Ishii, Genichiro; Goto, Koichi; Kubota, Kaoru; Ohmatsu, Hironobu; Niho, Seiji; Nagai, Kanji; Saijo, Nagahiro

    2008-12-01

    This study was conducted to evaluate the prevalence of EGFR and KIT mutations in thymomas and thymic carcinomas as a means of exploring the potential for molecularly targeted therapy with tyrosine kinase inhibitors. Genomic DNA was isolated from 41 paraffin-embedded tumor samples obtained from 24 thymomas and 17 thymic carcinomas. EGFR exons 18, 19, and 21, and KIT exons 9, 11, 13, and 17, were analyzed for mutations by PCR and direct sequencing. Protein expression of EGFR and KIT was evaluated immunohistochemically. EGFR mutations were detected in 2 of 20 thymomas, but not in any of the thymic carcinomas. All of the EGFR mutations detected were missense mutations (L858R and G863D) in exon 21. EGFR protein was expressed in 71% of the thymomas and 53% of the thymic carcinomas. The mutational analysis of KIT revealed only a missense mutation (L576P) in exon 11 of one thymic carcinoma. KIT protein was expressed in 88% of the thymic carcinomas and 0% of the thymomas. The results of this study indicate that EGFR and KIT mutations in thymomas and thymic carcinomas are rare, but that many of the tumors express EGFR or KIT protein.

  11. Direct detection of methicillin-resistant Staphylococcus aureus from blood cultures using an immunochromatographic immunoassay-based MRSA rapid kit for the detection of penicillin-binding protein 2a.

    PubMed

    Shin, Kyeong Seob; Song, Hyung Geun; Kim, Haejung; Yoon, Sangsun; Hong, Seung Bok; Koo, Sun Hoe; Kim, Jimyung; Kim, Jongwan; Roh, Kyoung Ho

    2010-07-01

    Using an EZ-Step MRSA rapid kit, a novel screening test for methicillin-resistant Staphylococcus aureus (MRSA) that detects penicillin-binding protein 2a, 34 of 36 MRSA-positive clinical blood culture samples were positive on direct testing (sensitivity, 94.4%), whereas 21 of 21 methicillin-susceptible S. aureus-positive samples were negative (specificity, 100%).

  12. Human Papilloma Virus (HPV) self-sampling: do women accept it?

    PubMed

    Abdullah, Nik Nairan; Daud, Suzanna; Wang, Seok Mui; Mahmud, Zamalia; Mohd Kornain, Noor Kaslina; Al-Kubaisy, Waqar

    2018-04-01

    This study aims to determine the acceptability of Human Papilloma Virus (HPV) self-sampling and the factors associated with willingness to buy HPV self-sampling kit in the future. A total of 164 women aged 28-60 years old from Obstetrics & Gynaecology clinics at a teaching hospital performed HPV self-sampling using the Digene HC2 DNA collection kit. After samples were taken, the participants were given self-administered questionnaires. The majority of the participants were Malay (93.9%), had attained tertiary education (65.2%) and were employed (70.1%). The acceptability was good. More than half of the participants felt that self-sampling was easy. Only 1.2% felt that the procedure was difficult to perform. Most reported no pain at all during the procedure (66.9%). The commonest concern was getting a good sample (90.1%). A number of Pap smears were found to be significantly associated with the willingness to buy the HPV self-sampling kit. HPV self-sampling has the potential to be included in the cervical cancer screening programme. Impact Statement What is already known on this subject: HPV self-sampling is acceptable in some developed and developing countries. It is acceptable because it was easy to perform with very minimal pain or discomfort. Studies on the acceptance of self-screening are needed to plan a policy on self-sampling in the future. What the results of this study add: Our study adds new findings to the body of knowledge on self-sampling in the local population. We found that more women are willing to do the self-sampling at the clinic rather than at home. Although more than 90% expressed willingness to do self-sampling in the future, only 70% of them were willing to purchase the kit. Cost is a potential barrier to women who have the interest to perform the self-sampling. Given the global economic challenges, cost is inevitably an important predictor that we have to consider. What the implications are of these findings for clinical practice and/or further research: Future research should examine women from the rural areas and those who are resilient to Pap smear screening. In clinical practice, clinicians should acknowledge that cost is a potential barrier for women who are willing to do self-sampling. Self-sampling could be an option for women with no financial constraint to buy the kit. However, clinicians should counsel women so that they can make an informed choice in determining their screening method.

  13. STR-typing of ancient skeletal remains: which multiplex-PCR kit is the best?

    PubMed Central

    Harder, Melanie; Renneberg, Rebecca; Meyer, Patrick; Krause-Kyora, Ben; von Wurmb-Schwark, Nicole

    2012-01-01

    Aim To comparatively test nine commercially available short tandem repeat (STR)-multiplex kits (PowerPlex 16, 16HS, ES, ESI17, ESX17, S5 [all Promega]; AmpFiSTR Identifiler, NGM and SEfiler [all Applied Biosystems]) for their efficiency and applicability to analyze ancient and thus highly degraded DNA samples. Methods Fifteen human skeletal remains from the late medieval age were obtained and analyzed using the nine polymerase chain reaction assays with slightly modified protocols. Data were systematically compared to find the most meaningful and sensitive assay. Results The ESI, ESX, and NGM kits showed the best overall results regarding amplification success, detection rate, identification of heterozygous alleles, sex determination, and reproducibility of the obtained data. Conclusion Since application of these three kits enables the employment of different primer sequences for all the investigated amplicons, a combined application is recommended for best possible and – most importantly – reliable genetic analysis of ancient skeletal material or otherwise highly degraded samples, eg, from forensic cases. PMID:23100203

  14. [Preparation of freeze - drying control materials of IgG antibody against Schistosoma japonicum for immunodetection kits].

    PubMed

    Jin, Huang; Chun-Lian, Tang; Zu-Wu, Tu; Li, Tang; Ke-Hui, Zhang; Qian, Li; Jun, Ye

    2018-04-18

    To prepare freeze-drying control materials of IgG antibody against Schistosoma japonicum for detection kits. The serum samples of schistosomiasis patients from endemic areas and normal people without history of schistosome infection or contact with infested water in Hubei Province were collected. All the sera were detected by the method approved by China Food and Drug Administration and selected for preparation of quality control samples. Totally twelve positive quality control materials, ten negative quality control materials, and one sensitive and one precision quality control materials were screened. According to the positive serum level, the positive degrees of quality control materials were divided into strong, medium and weak levels. The stability could be valid for one year. The freeze-drying quality control materials of IgG antibody against S. japonicum for detection kits are prepared. They are easy to use and have good stability, and therefore, they may meet the requirement of quality control for the detection of schistosomiasis diagnostics kits.

  15. Development and validation of the AmpFℓSTR® Identifiler® Direct PCR Amplification Kit: a multiplex assay for the direct amplification of single-source samples.

    PubMed

    Wang, Dennis Y; Chang, Chien-Wei; Lagacé, Robert E; Oldroyd, Nicola J; Hennessy, Lori K

    2011-07-01

    The AmpFℓSTR(®) Identifiler(®) Direct PCR Amplification Kit is a new short tandem repeat multiplex assay optimized to allow the direct amplification of single-source blood and buccal samples on FTA(®) card without the need for sample purification and quantification. This multiplex assay has been validated according to the FBI/National Standards and SWGDAM guidelines. Validation results revealed that slight variations in primer concentration, master mix component concentration, and thermal cycling parameters did not affect the performance of the chemistry. The assay's sensitivity was demonstrated by amplifying known amounts of white blood cells spotted onto FTA(®) cards, and the assay's specificity was verified by establishing minimal cross-reactivity with nonhuman DNA. No effect on the age of the sample stored on the FTA(®) substrate was observed and full concordance was established in the population study. These findings of the validation study support the use of the Identifiler(®) Direct Kit for forensic standards and database samples genotyping. © 2011 American Academy of Forensic Sciences.

  16. Evaluation of commercial kits for dual extraction of DNA and RNA from human body fluids.

    PubMed

    Schweighardt, Andrew J; Tate, Courtney M; Scott, Kristina A; Harper, Kathryn A; Robertson, James M

    2015-01-01

    STR typing of DNA evidence can identify the donor with a high power of discrimination but cannot identify the tissue origin of a body-fluid stain. Using RNA to attribute a crime scene stain to a particular tissue may aid in reconstruction efforts. With blood from 10 donors, four DNA and RNA coextraction kits were evaluated by measuring yields and STR and mRNA profiles. T tests indicated some significant differences in kit performance. The Zymo Research ZR-Duet(™) kit performed best based on average DNA (41.4 ng) and mRNA (4.07 ng) yields and was the only kit to provide complete DNA/RNA profiles for all samples. The consistency of this kit was challenged by data from additional blood and saliva donors. Further testing is advised before a superior kit is unequivocally chosen. Stand-alone DNA or RNA purification generally offers higher yield, but coextraction may still allow successful STR profiling and tissue source identification. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  17. DogMATIC--A Remote Biospecimen Collection Kit for Biobanking.

    PubMed

    Milley, Kristi M; Nimmo, Judith S; Bacci, Barbara; Ryan, Stewart D; Richardson, Samantha J; Danks, Janine A

    2015-08-01

    Canine tumors are valuable comparative oncology models. This research was designed to create a sustainable biobank of canine mammary tumors for breast cancer research. The aim was to provide a well-characterized sample cohort for specimen sharing, data mining, and long-term research aims. Canine mammary tumors are most frequently managed at a local veterinary clinic or hospital. We adopted a biobank framework based on a large number of participating veterinary hospitals and clinics acting as collection centers that were serviced by a centralized storage facility. Recruitment was targeted at rural veterinary clinics. A tailored, stable collection kit (DogMATIC) was designed that was used by veterinarians in remote or rural locations to collect both fresh and fixed tissue for submission to the biobank. To validate this methodology the kit design, collection rate, and sample quality were analyzed. The Australian Veterinary Cancer Biobank was established as a network of 47 veterinary clinics and three veterinary pathology laboratories spanning over 200,000 km(2). In the first 12 months, 30 canine mammary tumor cases were submitted via the DogMATIC kit. Pure intact RNA was isolated in over 80% of samples with an average yield of 14.49 μg. A large network biobank, utilizing off-site collection with the DogMATIC kit, was successfully coordinated. The creation of the Australian Veterinary Cancer Biobank has established a long-term, sustainable, comparative oncology research resource in Australia. There are broader implications for biobanking with this very different form of collection and banking.

  18. A simple field kit for the determination of drug susceptibility in Plasmodium falciparum.

    PubMed

    Nguyen-Dinh, P; Magloire, R; Chin, W

    1983-05-01

    A field kit has been developed which greatly simplifies the performance of the 48-hour in vitro test for drug resistance in Plasmodium falciparum. The kit uses an easily reconstituted lyophilized culture medium, and requires only a fingerprick blood sample. In parallel tests with 13 isolates of P. falciparum in Haiti, the new technique had a success rate equal to that of the previously described method, with comparable results in terms of parasite susceptibility in vitro to chloroquine and pyrimethamine.

  19. Computerized Online Bibliographic Searching. SPEC Kit #154.

    ERIC Educational Resources Information Center

    Hocker, Susan

    For this kit, 106 Association of Research Libraries (ARL) academic libraries were surveyed concerning: (1) current administration/organization; (2) evaluation; (3) patron relations; (4) services; and (5) the impact of online searching on collections. Responses were received from 83 libraries, many of which contributed sample materials. Analyses of…

  20. Low sensitivity and frequent cross-reactions in commercially available antibody detection ELISA assays for Taenia solium cysticercosis.

    PubMed

    Garcia, Hector H; Castillo, Yesenia; Gonzales, Isidro; Bustos, Javier A; Saavedra, Herbert; Jacob, Louis; Del Brutto, Oscar H; Wilkins, Patricia P; Gonzalez, Armando E; Gilman, Robert H

    2018-01-01

    To evaluate the diagnostic performance of two commercially available ELISA kits, Novalisa ® and Ridascreen ® , for the detection of antibodies to Taenia solium, compared to serological diagnosis of neurocysticercosis (NCC) by LLGP-EITB (electro-immunotransfer blot assay using lentil-lectin purified glycoprotein antigens). Archive serum samples from patients with viable NCC (n = 45) or resolved, calcified NCC (n = 45), as well as sera from patients with other cestode parasites (hymenolepiasis, n = 45 and cystic hydatid disease, n = 45), were evaluated for cysticercosis antibody detection using two ELISA kits, Novalisa ® and Ridascreen ® . All NCC samples had previously tested positive, and all samples from heterologous infections were negative on LLGP-EITB for cysticercosis. Positive rates were calculated by kit and sample group and compared between the two kits. Compared to LLGP-EITB, the sensitivity of both ELISA assays to detect specific antibodies in patients with viable NCC was low (44.4% and 22.2%), and for calcified NCC, it was only 6.7% and 4.5%. Sera from patients with cystic hydatid disease were highly cross-reactive in both ELISA assays (38/45, 84.4%; and 25/45, 55.6%). Sera from patients with hymenolepiasis cross-reacted in five cases in one of the assays (11.1%) and in only one sample with the second assay (2.2%). The performance of Novalisa ® and Ridascreen ® was poor. Antibody ELISA detection cannot be recommended for the diagnosis of neurocysticercosis. © 2017 John Wiley & Sons Ltd.

  1. Performance Evaluation of a Novel Chemiluminescence Assay Detecting Treponema Pallidum Antibody as a Syphilis Screening Method.

    PubMed

    Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin

    2016-01-01

    Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.

  2. Evaluation of Two Commercial Real-Time PCR Kits for Aspergillus DNA Detection in Bronchoalveolar Lavage Fluid in Patients with Invasive Pulmonary Aspergillosis.

    PubMed

    Denis, Julie; Forouzanfar, Faezeh; Herbrecht, Raoul; Toussaint, Elise; Kessler, Romain; Sabou, Marcela; Candolfi, Ermanno; Letsher-Bru, Valérie

    2018-05-01

    Invasive pulmonary aspergillosis (IPA) is a common complication of immunosuppression. Rapid diagnosis using molecular techniques is essential to improve patient survival. PCR techniques are promising in enhancing Aspergillus detection in blood and respiratory samples. We evaluate for the first time the performances of two commercial real-time PCR kits, the A. fumigatus Bio-Evolution and the MycoGENIE A. fumigatus for the detection of A. fumigatus DNA in bronchoalveolar lavage (BAL) from patients with and without IPA. Seventy-three BAL samples were included. Thirty-one of them corresponded to patients with probable IPA, 11 to patients with possible IPA, and 31 to patients without aspergillosis, according to the 2008 European Organization for Research and Treatment of Cancer/Mycoses Study Group criteria. In the probable IPA group, A. fumigatus Bio-Evolution and the MycoGENIE A. fumigatus real-time PCR kits showed a specificity of 100% and a sensitivity of 81% and 71%, respectively. The A. fumigatus Bio-Evolution detected Aspergillus DNA in the 14 BAL samples with a positive Aspergillus culture result, whereas the MycoGENIE A. fumigatus PCR result was positive only for 12. In the possible IPA group, there were no positive real-time PCR or positive Aspergillus culture results. For the patients without aspergillosis, no positive result was observed for real-time PCR kit, despite the presence of various other non-Aspergillus pathogens in this group. Our study demonstrates an excellent specificity and a good sensitivity of A. fumigatus DNA detection in BAL samples with both kits. Copyright © 2018 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  3. Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    PubMed Central

    2010-01-01

    Background Malaria rapid diagnostic tests (RDTs) are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution) or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands) showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74%) RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20), and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs). Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness) of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results. PMID:20650003

  4. Unreliability of three commercial Coxiella burnetii phase II IgM ELISA kits for the seroscreening of acute Q fever in human cases.

    PubMed

    Stephen, Selvaraj; Ambroise, Stanley; Pradeep, Jothimani; Gunasekaran, Dhandapany; Sangeetha, Balakrishnan; Sarangapani, Kengamuthu

    2017-09-01

    Seroprevalence of Q fever (QF) caused by Coxiella burnetii has been reported from different parts of India. Usually serological/molecular tests are employed for detection of infection. The present study was undertaken to verify the validity of three different QF phase II IgM ELISA kits for acute QF diagnosis by comparing with the gold standard indirect fluorescent antibody assay (IFA). Fifty eight serum samples collected from 42 patients (26 patients provided acute sample only and 16 both acute and convalescent samples) which were examined by all three commercial kits, were cross-checked with QF Phase II IgM IFA for confirmation. Eleven patients were positive for C. burnetii antibodies by IFA in acute and/or convalescent serum samples. Taking IFA as a reference, percentages of sensitivity, specificity, positive predictive value and negative predictive value for Virion-Serion/Vircell/NovaTec were 36.36, 61.29, 25.00, 73.08; 81.82, 35.48, 31.03, 84.62 and 100, 25.81, 32.35, 100 per cent, respectively. The three different ELISA kits exhibited poor agreement amongst them and unacceptable level of false positivity. IFA remains to be the only option for diagnosing acute QF. Discrepancy between the clinical findings and IFA/ELISA results needs confirmation by C. burnetii DNA detection in real-time polymerase chain reaction.

  5. Unreliability of three commercial Coxiella burnetii phase II IgM ELISA kits for the seroscreening of acute Q fever in human cases

    PubMed Central

    Stephen, Selvaraj; Ambroise, Stanley; Pradeep, Jothimani; Gunasekaran, Dhandapany; Sangeetha, Balakrishnan; Sarangapani, Kengamuthu

    2017-01-01

    Background & objectives: Seroprevalence of Q fever (QF) caused by Coxiella burnetii has been reported from different parts of India. Usually serological/molecular tests are employed for detection of infection. The present study was undertaken to verify the validity of three different QF phase II IgM ELISA kits for acute QF diagnosis by comparing with the gold standard indirect fluorescent antibody assay (IFA). Methods: Fifty eight serum samples collected from 42 patients (26 patients provided acute sample only and 16 both acute and convalescent samples) which were examined by all three commercial kits, were cross-checked with QF Phase II IgM IFA for confirmation. Results: Eleven patients were positive for C. burnetii antibodies by IFA in acute and/or convalescent serum samples. Taking IFA as a reference, percentages of sensitivity, specificity, positive predictive value and negative predictive value for Virion-Serion/Vircell/NovaTec were 36.36, 61.29, 25.00, 73.08; 81.82, 35.48, 31.03, 84.62 and 100, 25.81, 32.35, 100 per cent, respectively. Interpretation & conclusions: The three different ELISA kits exhibited poor agreement amongst them and unacceptable level of false positivity. IFA remains to be the only option for diagnosing acute QF. Discrepancy between the clinical findings and IFA/ELISA results needs confirmation by C. burnetii DNA detection in real-time polymerase chain reaction. PMID:29355147

  6. Reiter works with SWAB ASD Filter Kit in the U.S. Laboratory during Expedition 13

    NASA Image and Video Library

    2006-09-10

    ISS013-E-80066 (10 Sept. 2006) --- European Space Agency (ESA) astronaut Thomas Reiter, Expedition 13 flight engineer, works with the surface, water and air biocharacterization (SWAB) air sampling device (ASD) filter kit in the Destiny laboratory of the International Space Station.

  7. Enhanced Detection of Surface-Associated Bacteria in Indoor Environments by Quantitative PCR

    PubMed Central

    Buttner, Mark P.; Cruz-Perez, Patricia; Stetzenbach, Linda D.

    2001-01-01

    Methods for detecting microorganisms on surfaces are needed to locate biocontamination sources and to relate surface and airborne concentrations. Research was conducted in an experimental room to evaluate surface sampling methods and quantitative PCR (QPCR) for enhanced detection of a target biocontaminant present on flooring materials. QPCR and culture analyses were used to quantitate Bacillus subtilis (Bacillus globigii) endospores on vinyl tile, commercial carpet, and new and soiled residential carpet with samples obtained by four surface sampling methods: a swab kit, a sponge swipe, a cotton swab, and a bulk method. The initial data showed that greater overall sensitivity was obtained with the QPCR than with culture analysis; however, the QPCR results for bulk samples from residential carpet were negative. The swab kit and the sponge swipe methods were then tested with two levels of background biological contamination consisting of Penicillium chrysogenum spores. The B. subtilis values obtained by the QPCR method were greater than those obtained by culture analysis. The differences between the QPCR and culture data were significant for the samples obtained with the swab kit for all flooring materials except soiled residential carpet and with the sponge swipe for commercial carpet. The QPCR data showed that there were no significant differences between the swab kit and sponge swipe sampling methods for any of the flooring materials. Inhibition of QPCR due solely to biological contamination of flooring materials was not evident. However, some degree of inhibition was observed with the soiled residential carpet, which may have been caused by the presence of abiotic contaminants, alone or in combination with biological contaminants. The results of this research demonstrate the ability of QPCR to enhance detection and enumeration of biocontaminants on surface materials and provide information concerning the comparability of currently available surface sampling methods. PMID:11375164

  8. Knowledge, actual and potential use of HIV self-sampling testing kits among MSM recruited in eight European countries.

    PubMed

    Hoyos, J; Maté, T; Indave, B I; Agustí, C; Chanos, S; Pichon, F; Kuske, M; Cigan, B; Fuertes, R; Ooms, L; Stefanescu, R; Cabeza de Vaca, C; Arranz, B; de la Fuente, L; Belza, M J

    2018-02-01

    To describe the knowledge as well as current and potential use of self-sampling kits among men who have sex with men (MSM) and to analyse their preferred biological sample and result communication method. We analyse data of MSM of HIV negative or unknown serostatus from an online survey conducted in eight countries (Belgium, Denmark, Germany, Greece, Portugal, Romania, Slovenia and Spain) between April and December 2016. It was advertised mainly in gay dating websites. We conduct a descriptive analysis of the main characteristics of the participants, and present data on indicators of knowledge, use and potential use of HIV self-sampling as well as their preferences regarding blood or saliva sample and face or non-face-to-face result communication by country of residence. A total of 8.226 participants of HIV negative or unknown serostatus were included in the analysis. Overall, 25.5% of participants knew about self-sampling (range: 18.8-47.2%) and 1.1% had used it in the past (range: 0.3-8.9%). Potential use was high, with 66.6% of all participants reporting that they would have already used it if available in the past (range: 62.1-82.1%). Most (78.6%) reported that they would prefer using a blood-based kit, and receiving the result of the test through a non-face-to-face-method (70.8%), even in the case of receiving a reactive result. The high potential use reported by MSM recruited in eight different European countries suggests that self-sampling kits are a highly acceptable testing methodology that could contribute to the promotion of HIV testing in this population. © 2018 British HIV Association.

  9. Low-cost field test kits for arsenic detection in water.

    PubMed

    Das, Joyati; Sarkar, Priyabrata; Panda, Jigisha; Pal, Priyabrata

    2014-01-01

    Arsenic, a common contaminant of groundwater, affects human health adversely. According to the World Health Organization (WHO), the maximum recommended contamination level of arsenic in drinking water is 10 μg/L. The purpose of this research was to develop user-friendly kits for detection of arsenic to measure at least up to 10 μg/L in drinking water, so that a preventive measure could be taken. Two different kits for detection of total arsenic in water are reported here. First, the arsenic in drinking water was converted to arsine gas by a strong reducing agent. The arsine produced was then detected by paper strips via generation of color due to reaction with either mercuric bromide (KIT-1) or silver nitrate (KIT-2). These were previously immobilized on the detector strip. The first one gave a yellow color and the second one grey. Both of these kits could detect arsenic contamination within a range of 10 μg/L-250 μg/L. The detection time for both the kits was only 7 min. The kits exhibited excellent performance compared to other kits available in the market with respect to detection time, ease of operation, cost and could be easily handled by a layman. The field trials with these kits gave very satisfactory results. A study on interference revealed that these kits could be used in the presence of 24 common ions present in the arsenic contaminated water. Though the kits were meant for qualitative assay, the results with unknown concentrations of real samples, when compared with atomic absorption spectrophotometer (AAS) were in good agreement as revealed by the t-test.

  10. The stem cell growth factor receptor KIT is not expressed on interstitial cells in bladder.

    PubMed

    Gevaert, Thomas; Ridder, Dirk De; Vanstreels, Els; Daelemans, Dirk; Everaerts, Wouter; Aa, Frank Van Der; Pintelon, Isabel; Timmermans, Jean-Pierre; Roskams, Tania; Steiner, Clara; Neuhaus, Jochen

    2017-06-01

    The mast/stem cell growth factor receptor KIT has long been assumed to be a specific marker for interstitial cells of Cajal (ICC) in the bladder, with possible druggable perspectives. However, several authors have challenged the presence of KIT + ICC in recent years. The aim of this study was therefore to attempt to clarify the conflicting reports on KIT expression in the bladder of human beings, rat, mouse and guinea pig and to elucidate the possible role of antibody-related issues and interspecies differences in this matter. Fresh samples were obtained from human, rat, mouse and guinea pig cystectomies and processed for single/double immunohistochemistry/immunofluorescence. Specific antibodies against KIT, mast cell tryptase (MCT), anoctamin-1 (ANO1) and vimentin were used to characterize the cell types expressing KIT. Gut (jejunum) tissue was used as an external antibody control. Our results revealed KIT expression on mast cells but not on ICC in human, rat, mouse and guinea pig bladder. Parallel immunohistochemistry showed KIT expression on ICC in human, rat, mouse and guinea pig gut, which confirmed the selectivity of the KIT antibody clones. In conclusion, we have shown that KIT + cells in human, rat, mouse and guinea pig bladder are mast cells and not ICC. The present report is important as it opposes the idea that KIT + ICC are present in bladder. In this perspective, functional concepts of KIT + ICC being involved in sensory and/or motor aspects of bladder physiology should be revised. © 2016 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.

  11. Chlamyweb Study I: rationale, design and acceptability of an internet-based chlamydia testing intervention.

    PubMed

    Lydié, Nathalie; de Barbeyrac, Bertille; Bluzat, Lucile; Le Roy, Chloé; Kersaudy-Rahib, Delphine

    2017-05-01

    In recent years, the internet has widely facilitated Chlamydia trachomatis home-sampling. In France (2012), the Chlamyweb Study evaluated an intervention (Chlamyweb) involving home-based self-sampling via the internet. One element of the study consisted of a randomised controlled trial (RCT), which is reported in detail elsewhere. The focus of this paper, however, is on describing the Chlamyweb Intervention and reporting on the non-RCT element of the evaluation of that intervention by the Chlamyweb Study. This involves (1) describing the design and roll-out of the Chlamyweb Intervention, (2) comparing the socio-behavioural profiles of the participants in the intervention with a nationally representative general population sample and (3) examining the factors that influence the acceptance and return of a self-sampling kit supplied to participants in the course of the intervention. Self-sampling kits were offered to sexually active people aged 18-24 years living on the mainland French. Participants' characteristics were compared with the general population to describe recruited and participant populations. Multivariate analyses by conditional logistic regression were performed to determine factors that were predictors of kit acceptation and use. 7215 people aged 18-24 years were included. Compared with the general population, Chlamyweb reached larger proportions of women, younger people and people with several partners in the previous year. 3372 (46.7%) agreed to receive a self-sampling kit and 2084 (61.8%) returned it, with more women doing so than men. The participation rate was associated with age, place of birth, occupational status, number of partners and condom use, differently for men and women. The offer of easy-to-use, self-sampling kits free of charge appeared to be a logistically feasible strategy for testing in France and reached a large and diverse population including individuals who have limited access to the traditional healthcare system. AFFSAPS n° IDRCB 0211-A01000-41; pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  12. Comparative evaluation of different extraction and quantification methods for forensic RNA analysis.

    PubMed

    Grabmüller, Melanie; Madea, Burkhard; Courts, Cornelius

    2015-05-01

    Since about 2005, there is increasing interest in forensic RNA analysis whose versatility may very favorably complement traditional DNA profiling in forensic casework. There is, however, no method available specifically dedicated for extraction of RNA from forensically relevant sample material. In this study we compared five commercially available and commonly used RNA extraction kits and methods (mirVana™ miRNA Isolation Kit Ambion; Trizol® Reagent, Invitrogen; NucleoSpin® miRNA Kit Macherey-Nagel; AllPrep DNA/RNA Mini Kit and RNeasy® Mini Kit both Qiagen) to assess their relative effectiveness of yielding RNA of good quality and their compatibility with co-extraction of DNA amenable to STR profiling. We set up samples of small amounts of dried blood, liquid saliva, semen and buccal mucosa that were aged for different time intervals for co-extraction of RNA and DNA. RNA quality was assessed by determination of 'RNA integrity number' (RIN) and quantitative PCR based expression analysis. DNA quality was assessed via monitoring STR typing success rates. By comparison, the different methods exhibited considerable differences between RNA and DNA yields, RNA quality values and expression levels, and STR profiling success, with the AllPrep DNA/RNA Mini Kit and the NucleoSpin® miRNA Kit excelling at DNA co-extraction and RNA results, respectively. Overall, there was no 'best' method to satisfy all demands of comprehensible co-analysis of RNA and DNA and it appears that each method has specific merits and flaws. We recommend to cautiously choose from available methods and align its characteristics with the needs of the experimental setting at hand. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. High-quality and -quantity DNA extraction from frozen archival blood clots for genotyping of single-nucleotide polymorphisms.

    PubMed

    Bank, Steffen; Nexø, Bjørn Andersen; Andersen, Vibeke; Vogel, Ulla; Andersen, Paal Skytt

    2013-06-01

    The recovery of biological samples for genetic epidemiological studies can be cumbersome. Blood clots are routinely collected for serological examinations. However, the extraction of DNA from blood clots can be difficult and often results in low yields. The aim was to compare the efficiency of commercial purification kits for extracting DNA from long-term frozen clotted blood. Serum tubes with clotted blood were stored at -20°C for 1 to 2.5 years before DNA extraction. DNA was extracted from 10 blood clot samples using PureGene (Qiagen) with and without glycogen, the QIAamp DNA Micro kit (Qiagen), and the Nucleospin 96 Blood kit (Macherey-Nagel). Furthermore, blood clots from 1055 inflammatory bowel disease patients were purified using the Maxwell 16 Blood purification kit (Promega). The DNA was extracted according to the manufacturers` instructions and real-time PCR and the A(260)/A(280) ratio were used to evaluate the quality of the extracted DNA. The highest DNA yield was obtained by the Maxwell 16 Blood purification kit (Promega) with a median of 4.90 μg (range 0.8-25 μg) pr 300 μL total blood. PureGene with glycogen (Qiagen) had the second highest yield with a median of 0.65 μg (range 0.5-2.6 μg) pr 300 μL total blood. The yield obtained by the different commercial kits varied considerably. Our work demonstrates that high-quality and -quantity DNA can be extracted with the Maxwell 16 Blood purification kit (Promega) from cryopreserved blood clots, even after prolonged storage. The recovered DNA served as a reliable PCR template for single-nucleotide polymorphism assays.

  14. Development and validation of an ELISA kit (YF MAC-HD) to detect IgM to yellow fever virus.

    PubMed

    Basile, Alison Jane; Goodman, Christin; Horiuchi, Kalanthe; Laven, Janeen; Panella, Amanda J; Kosoy, Olga; Lanciotti, Robert S; Johnson, Barbara W

    2015-12-01

    Yellow fever virus (YFV) is endemic in tropical and sub-tropical regions of the world, with around 180,000 human infections a year occurring in Africa. Serologic testing is the chief laboratory diagnostic means of identifying an outbreak and to inform the decision to commence a vaccination campaign. The World Health Organization disseminates the reagents for YFV testing to African reference laboratories, and the US Centers for Disease Control and Prevention (CDC) is charged with producing and providing these reagents. The CDC M-antibody capture ELISA is a 2-day test, requiring titration of reagents when new lots are received, which leads to inconsistency in testing and wastage of material. Here we describe the development of a kit-based assay (YF MAC-HD) based upon the CDC method, that is completed in approximately 3.5h, with equivocal samples being reflexed to an overnight protocol. The kit exhibits >90% accuracy when compared to the 2-day test. The kits were designed for use with a minimum of equipment and are stored at 4°C, removing the need for freezing capacity. This kit is capable of tolerating temporary sub-optimal storage conditions which will ease shipping or power outage concerns, and a shelf life of >6 months was demonstrated with no deterioration in accuracy. All reagents necessary to run the YF MAC-HD are included in the kit and are single-use, with 8 or 24 sample options per kit. Field trials are envisioned for the near future, which will enable refinement of the method. The use of the YF MAC-HD is anticipated to reduce materials wastage, and improve the quality and consistency of YFV serologic testing in endemic areas. Published by Elsevier B.V.

  15. Comparison of clinical application of the Abbott HBV PCR kit and the VERSANT HBV DNA 3.0 test to measure serum hepatitis B virus DNA in Taiwanese patients.

    PubMed

    Yang, Jeng-Fu; Lin, Ya-Yun; Huang, Jee-Fu; Liu, Shu-Fen; Chu, Pei-Yu; Hsieh, Ming-Yen; Lin, Zu-Yau; Chen, Shinn-Cherng; Wang, Liang-Yen; Dai, Chia-Yen; Chuang, Wan-Long; Yu, Ming-Lung

    2009-08-01

    With an estimated 350-400 million people worldwide chronically infected with hepatitis B virus (HBV), and the subsequent serious complications caused by liver damage including cirrhosis, liver failure, and hepatocellular carcinoma, HBV infection remains a global health issue, particularly in Taiwan, an HBV-hyperendemic area. Sensitive and accurate quantification of HBV DNA is necessary to monitor patients with chronic hepatitis B who are receiving antiviral therapy to determine treatment response and adapt therapy. We evaluated and compared the clinical performance of two HBV DNA assays based on different technologies: the RealArt HBV PCR Kit (Abbott HBV DNA PCR kit, real-time polymerase chain reaction assay, detection limit: 27 IU/mL) and the VERSANT bDNA 3.0 assay (Bayer, branched DNA signal amplification assay, detection limit: 357 IU/mL). Serum levels of HBV DNA in 173 chronic HBV carriers were determined using both the RealArt HBV PCR Kit and the VERSANT bDNA 3.0 test. Of the 173 samples analyzed for baseline viral load detection, HBV DNA was quantifiable in 147 patients (82.1%) by the RealArt HBV PCR Kit, which was significantly higher than the 92 (53.2%) samples quantified by the VERSANT bDNA 3.0 assay. A total of 86 (49.7%) samples were quantifiable by both assays, whereas 25 (14.5%) were below the detection limit of both assays. The HBV DNA quantification values measured by the RealArt HBV PCR Kit and the VERSANT bDNA 3.0 assay were positively correlated (Spearman's rank correlation coefficient r = 0.932, p < 0.001). On average, the results derived from the RealArt HBV PCR Kit were 0.67 log lower than those of the VERSANT bDNA 3.0 assay. HBV DNA concentrations were significantly higher in 63 HBV e antigen (HBeAg)-seropositive patients than in 110 HBeAg-seronegative patients (5.42 +/- 2.34 logs vs. 3.21 +/- 2.27 logs, p < 0.001). The RealArt HBV PCR Kit is more sensitive and has a wider dynamic range than the VERSANT bDNA 3.0 assay in the clinical setting of chronic hepatitis B patients. The sensitivity and wide dynamic range of the PCR assay allow optimal monitoring and timely adaptation of antiviral therapy. Nevertheless, the HBV DNA values measured by the RealArt HBV PCR Kit and the VERSANT bDNA 3.0 assay were significantly correlated.

  16. An indigenously developed nitrite kit to aid in the diagnosis of urinary tract infection.

    PubMed

    Sood, S; Upadhyaya, P; Kapil, A; Lodha, R; Jain, Y; Bagga, A

    1999-09-01

    To evaluate the utility of an indigenously developed nitrite kit for the rapid diagnosis of urinary tract infection (UTI) METHODS: 1018 urine specimens were collected from all cases where there was clinical suspicion of UTI. Samples were cultured as per standard microbiological protocol. Presence of nitrites was indicated by the development of purple color on addition of color developing solution and compared with the set of graded positive and negative controls also provided in the Kit. The results of the nitrite kit were compared with the semi-quantitative urine culture as the gold standard. The sensitivity, specificity, positive predictive and negative predictive values were 47%, 87%, 31% and 93%, respectively. Nitrite kit as a screening test can decrease the work load in the clinical bacteriology laboratory. More importantly in a field set up that is devoid of culture facilities, it can be used to correctly predict the absence of UTI.

  17. TECHNOLOGIES FOR MONITORING AND MEASUREMENT ...

    EPA Pesticide Factsheets

    A demonstration of technologies for determining the presence of dioxin and dioxin-like compounds in soil and sediment was conducted under EPA's Superfund Innovative Technology Evaluation Program in Saginaw, Michigan in April 2004. This report describes the performance evaluation of CAPE Technologies DF-1 Dioxin/Furan and PCB TEQ Immunoassay Kits. The kits are immunoassay techniques that report the total toxicity equivalents (TEQ) of dioxin/furans and polychlorinated biphenyls (PCBs. The technology results were compared to high resolution mass spectrometry TEQ results generated using EPA Methods 1613B and 1668A.The CAPE Technologies kits generally reported data higher than the certified PE and reference laboratory values. The technologys estimated MDL was 12 to 33 pg/g TEQ. Results from this demonstration suggest that the CAPE Technologies kits could be an effective screening tool for determining sample results above and below 20 pg/g TEQ and even more effective as a screen for sample above and below 50 pg/g TEQ, particularly considering that both the cost ($59,234 vs. $398,029) and the time (3 weeks vs. 8 months) to analyze the 209 demonstration samples were significantly less than those of the reference laboratory. The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented performance and cost data obtained from field demonstrations.

  18. Clinical evaluation of a new single-tube multiplex reverse transcription PCR assay for simultaneous detection of 11 respiratory viruses, Mycoplasma pneumoniae and Chlamydia in hospitalized children with acute respiratory infections.

    PubMed

    Zhao, Meng-Chuan; Li, Gui-Xia; Zhang, Dan; Zhou, Hang-Yu; Wang, Hao; Yang, Shuo; Wang, Le; Feng, Zhi-Shan; Ma, Xue-Jun

    2017-06-01

    Respiratory Pathogen 13 Detection Kit (13× kit) is able to simultaneously detect 11 respiratory viruses, Mycoplasma pneumoniae (MP) and Chlamydia in a single reaction. Using 572 Nasopharyngeal aspirates collected from hospitalized children, the clinical performance of 13× kit for detecting 11 respiratory viruses was evaluated in comparison with a routinely used 2-tube multiplex reverse transcription PCR assay (2-tube assay) at provincial Centers for Disease Control and Prevention in China. The clinical performance of 13× kit for detecting MP and Chlamydia was evaluated by commercial real-time quantitative PCR (qPCR) kits or sequencing. For tested viruses, the assay concordance was 95.98% and the kappa coefficient was 0.89. All the MP and Chlamydia positive samples detected by 13× kit were confirmed as true positives. The utilization of the 13× kit in clinical settings will be helpful for doctors to assess clinical outcome according to virus type or multiple infections, and to limit the use of antibiotics. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Performance evaluation of a chemiluminescence microparticle immunoassay for CK-MB.

    PubMed

    Lin, Zhi-Yuan; Fang, Yi-Zhen; Jin, Hong-Wei; Lin, Hua-Yue; Dai, Zhang; Luo, Qing; Li, Hong-Wei; Lin, Yan-Ling; Huang, Shui-Zhen; Gao, Lei; Xu, Fei-Hai; Zhang, Zhong-Ying

    2018-03-31

    To verify and evaluate the performance characteristics of a creatine kinase phosphokinase isoenzymes MB (CK-MB) assay kit, which produced by Xiamen Innodx Biotech Co. Ltd. Evaluation was carried out according to "Guidelines for principle of analysis performance evaluation of in vitro diagnostic reagent." The performance parameters included detection limit, linearity range, reportable range, recovery test, precision verification, interference test, cross-reactivity, matrix effect, and method comparison. The detection limit was 0.1 ng/mL. The assay had clinical linearity over range of 0.1 ng/mL-500 ng/mL. Reportable range was from 0.1 ng/mL to 1000 ng/mL. The average percent of recovery was 99.66%. The coefficient of variation (CV) for within-run and between-run of low CK-MB sample was 5.55% and 6.16%, respectively. As for high-level sample, it was 7.88% and 7.80%. In medical decision level, the relative deviation (Bias) of all interference tests was lower than 15%. When the sample had mild-hemolysis; hemoglobin ≤15 g/L; triglyceride ≤17 mmol/L; bilirubin ≤427.5 μmol/L; rheumatoid factor ≤206U/mL, there was no significant interference to be found. Moreover, assay kit had no cross-reaction with CK-MM and CK-BB. At last, total diagnostic accuracy of kit was 93.24%, when compared with refer kit. Overall the results of the verification study indicated the performance of kit is met the requirements of the clinical test. © 2018 Wiley Periodicals, Inc.

  20. Therapeutic drug monitoring of infliximab: performance evaluation of three commercial ELISA kits.

    PubMed

    Schmitz, Ellen M H; van de Kerkhof, Daan; Hamann, Dörte; van Dongen, Joost L J; Kuijper, Philip H M; Brunsveld, Luc; Scharnhorst, Volkher; Broeren, Maarten A C

    2016-07-01

    Therapeutic drug monitoring (TDM) of infliximab (IFX, Remicade®) can aid to optimize therapy efficacy. Many assays are available for this purpose. However, a reference standard is lacking. Therefore, we evaluated the analytical performance, agreement and clinically relevant differences of three commercially available IFX ELISA kits on an automated processing system. The kits of Theradiag (Lisa Tracker Infliximab), Progenika (Promonitor IFX) and apDia (Infliximab ELISA) were implemented on an automated processing system. Imprecision was determined by triplicate measurements of patient samples on five days. Agreement was evaluated by analysis of 30 patient samples and four spiked samples by the selected ELISA kits and the in-house IFX ELISA of Sanquin Diagnostics (Amsterdam, The Netherlands). Therapeutic consequences were evaluated by dividing patients into four treatment groups using cut-off levels of 1, 3 and 7 μg/mL and determining assay concordance. Within-run and between-run imprecision were acceptable (≤12% and ≤17%, respectively) within the quantification range of the selected ELISA kits. The apDia assay had the best precision and agreement to target values. Statistically significant differences were found between all assays except between Sanquin Diagnostics and the Lisa Tracker assay. The Promonitor assay measured the lowest IFX concentrations, the apDia assay the highest. When patients were classified in four treatment categories, 70% concordance was achieved. Although all assays are suitable for TDM, significant differences were observed in both imprecision and agreement. Therapeutic consequences were acceptable when patients were divided in treatment categories, but this could be improved by assay standardization.

  1. How To Sample in Surveys. The Survey Kit, Volume 6.

    ERIC Educational Resources Information Center

    Fink, Arlene

    The nine-volume Survey Kit is designed to help readers prepare and conduct surveys and become better users of survey results. All the books in the series contain instructional objectives, exercises and answers, examples of surveys in use, illustrations of survey questions, guidelines for action, checklists of "dos and don'ts," and…

  2. Repression of c-Kit by p53 is mediated by miR-34 and is associated with reduced chemoresistance, migration and stemness

    PubMed Central

    Siemens, Helge; Jackstadt, Rene; Kaller, Markus; Hermeking, Heiko

    2013-01-01

    The c-Kit receptor tyrosine kinase is commonly over-expressed in different types of cancer. p53 activation is known to result in the down-regulation of c-Kit. However, the underlying mechanism has remained unknown. Here, we show that the p53-induced miR-34 microRNA family mediates repression of c-Kit by p53 via a conserved seed-matching sequence in the c-Kit 3'-UTR. Ectopic miR-34a resulted in a decrease in Erk signaling and transformation, which was dependent on the down-regulation of c-Kit expression. Furthermore, ectopic expression of c-Kit conferred resistance of colorectal cancer (CRC) cells to treatment with 5-fluorouracil (5-FU), whereas ectopic miR-34a sensitized the cells to 5-FU. After stimulation with c-Kit ligand/stem cell factor (SCF) Colo320 CRC cells displayed increased migration/invasion, whereas ectopic miR-34a inhibited SCF-induced migration/invasion. Activation of a conditional c-Kit allele induced several stemness markers in DLD-1 CRC cells. In primary CRC samples elevated c-Kit expression also showed a positive correlation with markers of stemness, such as Lgr5, CD44, OLFM4, BMI-1 and β-catenin. On the contrary, activation of a conditional miR-34a allele in DLD-1 cells diminished the expression of c-Kit and several stemness markers (CD44, Lgr5 and BMI-1) and suppressed sphere formation. MiR-34a also suppressed enhanced sphere-formation after exposure to SCF. Taken together, our data establish c-Kit as a new direct target of miR-34 and demonstrate that this regulation interferes with several c-Kit-mediated effects on cancer cells. Therefore, this regulation may be potentially relevant for future diagnostic and therapeutic approaches. PMID:24009080

  3. Audit of lymphadenectomy in lung cancer resections using a specimen collection kit and checklist

    PubMed Central

    Osarogiagbon, Raymond U.; Sareen, Srishti; Eke, Ransome; Yu, Xinhua; McHugh, Laura M.; Kernstine, Kemp H.; Putnam, Joe B.; Robbins, Edward T.

    2014-01-01

    Background Audits of operative summaries and pathology reports reveal wide discordance in identifying the extent of lymphadenectomy performed (the communication gap). We tested the ability of a pre-labeled lymph node specimen collection kit and checklist to narrow the communication gap between operating surgeons, pathologists, and auditors of surgeons’ operation notes. Methods We conducted a prospective single cohort study of lung cancer resections performed with a lymph node collection kit from November 2010 to January 2013. We used the kappa statistic to compare surgeon claims on a checklist of lymph node stations harvested intraoperatively, to pathology reports, and an independent audit of surgeons’ operative summaries. Lymph node collection procedures were classified into 4 groups based on the anatomic origin of resected lymph nodes: mediastinal lymph node dissection, systematic sampling, random sampling and no sampling. Results From the pathology report, 73% of 160 resections had a mediastinal lymph node dissection or systematic sampling procedure, 27% had random sampling. The concordance with surgeon claims was 80% (kappa statistic 0.69 [CI 0.60 – 0.79]). Concordance between independent audits of the operation notes and either the pathology report (kappa 0.14 [0.04 – 0.23]), or surgeon claims (kappa 0.09 [0.03 – 0.22]), was poor. Conclusion A pre-labeled specimen collection kit and checklist significantly narrowed the communication gap between surgeons and pathologists in identifying the extent of lymphadenectomy. Audit of surgeons’ operation notes did not accurately reflect the procedure performed, bringing its value for quality improvement work into question. PMID:25530090

  4. Survey of undeclared soy allergen levels in the most frequently recalled food categories with or without precautionary labelling.

    PubMed

    Khuda, Sefat E; Sharma, Girdhari M; Gaines, Dennis; Do, Andrew B; Pereira, Marion; Chang, Michael; Ferguson, Martine; Williams, Kristina M

    2016-08-01

    A comprehensive study was designed to determine the frequency and levels of soy allergen in packaged bakery and snack food products. A representative sample of products with no soy allergen disclosed on the label was analysed using two widely used enzyme-linked immunosorbent assay (ELISA) methods. Samples were chosen that either had no soy identified on the product label or which had a soy precautionary statement. Among 558 bakery and snack products, soy protein was detected in 17% of the products using the Neogen (NE) kit and 11% of the products using the Elisa Systems (ES) kit. The disagreement rates between kits were 8.8% for bakery products and 3.3% for snack products. Overall soy protein was detected at higher frequency in bakery products than in snack foods. Among 284 bakery samples, soy protein was detected in 25% of the samples with no precautionary statement and 19% of the samples which had a precautionary statement. Among 274 snack samples, soy protein was detected in 11% of the samples with no precautionary statement and 9% of the samples which had a precautionary statement. The sample repeatability was at an acceptable level (< 9%) for each method and food commodity. The reproducibility between kits was 23% for bakery foods and 36% for snack foods. None of the bakery (21) and snack (6) products without precautionary labelling (measured level > 5 ppm) had a higher level of soy protein per serving compared with the eliciting dose10 (ED10) of 10.6 mg for soy allergic patients. But the level of soy protein per serving may be clinically relevant to a subpopulation of soy allergic patients if a more stringent eliciting dose is applied. These findings emphasise that suitable detection methodologies and references doses are crucial for labelling accuracy and the safety of soy allergic consumers.

  5. Evaluation of tyrosine-kinase receptor c-KIT (c-KIT) mutations, mRNA and protein expression in canine leukemia: might c-KIT represent a therapeutic target?

    PubMed

    Giantin, M; Aresu, L; Aricò, A; Gelain, M E; Riondato, F; Martini, V; Comazzi, S; Dacasto, M

    2013-04-15

    The tyrosine-kinase receptor c-KIT (c-KIT) plays an important role in proliferation, survival and differentiation of progenitor cells in normal hematopoietic cells. In human hematological malignancies, c-KIT is mostly expressed by progenitor cell neoplasia and seldom by those involving mature cells. Tyrosine kinase inhibitors (TKIs) are actually licensed for the first- and second-line treatment of human hematologic disorders. Aim of the present study was to evaluate c-KIT mRNA and protein expression and complementary DNA (cDNA) mutations in canine leukemia. Eleven acute lymphoblastic leukemia (ALL) and acute undifferentiated leukemia (AUL) and 12 chronic lymphocytic leukemia (CLL) were enrolled in this study. The amounts of c-KIT mRNA and protein were determined, in peripheral blood samples, by using quantitative real time RT-PCR, flow cytometry and immunocytochemistry, respectively. The presence of mutations on c-KIT exons 8-11 and 17 were investigated by cDNA sequencing. Higher amounts of c-KIT mRNA were found in ALL/AUL compared to CLL, and this latter showed a lower pattern of gene expression. Transcriptional data were confirmed at the protein level. No significant gain-of-function mutations were ever observed in both ALL/AUL and CLL. Among canine hematological malignancies, ALL/AUL typically show a very aggressive biological behavior, partly being attributable to the lack of efficacious therapeutic options. The high level of c-KIT expression found in canine ALL/AUL might represent the rationale for using TKIs in future clinical trials. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Digital PCR: A Sensitive and Precise Method for KIT D816V Quantification in Mastocytosis.

    PubMed

    Greiner, Georg; Gurbisz, Michael; Ratzinger, Franz; Witzeneder, Nadine; Simonitsch-Klupp, Ingrid; Mitterbauer-Hohendanner, Gerlinde; Mayerhofer, Matthias; Müllauer, Leonhard; Sperr, Wolfgang R; Valent, Peter; Hoermann, Gregor

    2018-03-01

    The analytically sensitive detection of KIT D816V in blood and bone marrow is important for diagnosing systemic mastocytosis (SM). Additionally, precise quantification of the KIT D816V variant allele fraction (VAF) is relevant clinically because it helps to predict multilineage involvement and prognosis in cases of advanced SM. Digital PCR (dPCR) is a promising new method for sensitive detection and accurate quantification of somatic mutations. We performed a validation study of dPCR for KIT D816V on 302 peripheral blood and bone marrow samples from 156 patients with mastocytosis for comparison with melting curve analysis after peptide nucleic acid-mediated PCR clamping (clamp-PCR) and allele-specific quantitative real-time PCR (qPCR). dPCR showed a limit of detection of 0.01% VAF with a mean CV of 8.5% and identified the mutation in 90% of patients compared with 70% for clamp-PCR ( P < 0.001). Moreover, dPCR for KIT D816V was highly concordant with qPCR without systematic deviation of results, and confirmed the clinical value of KIT D816V VAF measurements. Thus, patients with advanced SM showed a significantly higher KIT D816V VAF (median, 2.43%) compared with patients with indolent SM (median, 0.14%; P < 0.001). Moreover, dPCR confirmed the prognostic significance of a high KIT D816V VAF regarding survival ( P < 0.001). dPCR for KIT D816V provides a high degree of precision and sensitivity combined with the potential for interlaboratory standardization, which is crucial for the implementation of KIT D816V allele burden measurement. Thus, dPCR is suitable as a new method for KIT D816V testing in patients with mastocytosis. © 2017 American Association for Clinical Chemistry.

  7. Gene expression in gastrointestinal stromal tumors is distinguished by KIT genotype and anatomic site.

    PubMed

    Antonescu, Cristina R; Viale, Agnes; Sarran, Lisa; Tschernyavsky, Sylvia J; Gonen, Mithat; Segal, Neil H; Maki, Robert G; Socci, Nicholas D; DeMatteo, Ronald P; Besmer, Peter

    2004-05-15

    Gastrointestinal stromal tumors (GISTs) are specific KIT expressing and KIT-signaling driven mesenchymal tumors of the human digestive tract, many of which have KIT-activating mutations. Previous studies have found a relatively homogeneous gene expression profile in GIST, as compared with other histological types of sarcomas. Transcriptional heterogeneity within clinically or molecularly defined subsets of GISTs has not been previously reported. We tested the hypothesis that the gene expression profile in GISTs might be related to KIT genotype and possibly to other clinicopathological factors. An HG-U133A Affymetrix chip (22,000 genes) platform was used to determine the variability of gene expression in 28 KIT-expressing GIST samples from 24 patients. A control group of six intra-abdominal leiomyosarcomas was also included for comparison. Statistical analyses (t tests) were performed to identify discriminatory gene lists among various GIST subgroups. The levels of expression of various GIST subsets were also linked to a modified version of the growth factor/KIT signaling pathway to analyze differences at various steps in signal transduction. Genes involved in KIT signaling were differentially expressed among wild-type and mutant GISTs. High gene expression of potential drug targets, such as VEGF, MCSF, and BCL2 in the wild-type group, and Mesothelin in exon 9 GISTs were found. There was a striking difference in gene expression between stomach and small bowel GISTs. This finding was validated in four separate tumors, two gastric and two intestinal, from a patient with familial GIST with a germ-line KIT W557R substitution. GISTs have heterogeneous gene expression depending on KIT genotype and tumor location, which is seen at both the genomic level and the KIT signaling pathway in particular. These findings may explain their variable clinical behavior and response to therapy.

  8. Evaluation of DNA extraction methods for PCR-based detection of Listeria monocytogenes from vegetables.

    PubMed

    Vojkovska, H; Kubikova, I; Kralik, P

    2015-03-01

    Epidemiological data indicate that raw vegetables are associated with outbreaks of Listeria monocytogenes. Therefore, there is a demand for the availability of rapid and sensitive methods, such as PCR assays, for the detection and accurate discrimination of L. monocytogenes. However, the efficiency of PCR methods can be negatively affected by inhibitory compounds commonly found in vegetable matrices that may cause false-negative results. Therefore, the sample processing and DNA isolation steps must be carefully evaluated prior to the introduction of such methods into routine practice. In this study, we compared the ability of three column-based and four magnetic bead-based commercial DNA isolation kits to extract DNA of the model micro-organism L. monocytogenes from raw vegetables. The DNA isolation efficiency of all isolation kits was determined using a triplex real-time qPCR assay designed to specifically detect L. monocytogenes. The kit with best performance, the PowerSoil(™) Microbial DNA Isolation Kit, is suitable for the extraction of amplifiable DNA from L. monocytogenes cells in vegetable with efficiencies ranging between 29.6 and 70.3%. Coupled with the triplex real-time qPCR assay, this DNA isolation kit is applicable to the samples with bacterial loads of 10(3) bacterial cells per gram of L. monocytogenes. Several recent outbreaks of Listeria monocytogenes have been associated with the consumption of fruits and vegetables. Real-time PCR assays allow fast detection and accurate quantification of microbes. However, the success of real-time PCR is dependent on the success with which template DNA can be extracted. The results of this study suggest that the PowerSoil(™) Microbial DNA Isolation Kit can be used for the extraction of amplifiable DNA from L. monocytogenes cells in vegetable with efficiencies ranging between 29.6 and 70.3%. This method is applicable to samples with bacterial loads of 10(3) bacterial cells per gram of L. monocytogenes. © 2014 The Society for Applied Microbiology.

  9. On-farm biosecurity practices and causes of preweaning mortality in Canadian commercial mink kits.

    PubMed

    Compo, Nicole; Pearl, David L; Tapscott, Brian; Storer, Amanda; Hammermueller, Jutta; Brash, Marina; Turner, Patricia V

    2017-09-08

    Mink are an important animal commodity group in Canada and excessive kit mortality represents a significant loss to production. National biosecurity standards have been developed for Canadian mink farms, but it is unclear how well these standards have been implemented as there are no studies correlating management practices of mink producers with causes of death in mink kits. To that end, we surveyed Ontario mink producers on their biosecurity and management practices and conducted almost 5660 post mortem examinations on found-dead, preweaned kits to characterize mink farm biosecurity practices and causes of death in preweaned kits. We found that very few biosecurity and management practices were uniformly used by producers, despite good awareness of appropriate practices. Use of personal protective equipment was implemented by fewer than 50% of respondents, while control of mink shed access, disinfection of feed containers after use, and use of a rodent control program were the only practices implemented by greater than 70% of respondents. Only 18% of producers reported regular use of antimicrobials in feed or water, although 91% stated they used antimicrobials for treatment of bacterial diseases on a regular basis. On post mortem examination, no gross abnormalities were noted in 71% of the kits, 45% were thought to be stillborn or aborted, 27% had some form of abnormal fluid distribution in the body, and 2% had a congenital malformation. A subset of 69 gastrointestinal tract samples was submitted for bacterial culture, of which 45 samples yielded sufficient growth. Most interesting was the identification of Salmonella enterica serovar Heidelberg in 11% of samples. The results of this study will provide a benchmark for Canadian mink producers and their veterinarians, defining the areas to which greater attention should be given to ensure more rigorous biosecurity practices are in place. Ultimately, these improvements in practices may contribute to increased mink production and animal well-being.

  10. Attitudes towards HIV testing via home-sampling kits ordered online (RUClear pilots 2011-12).

    PubMed

    Ahmed-Little, Y; Bothra, V; Cordwell, D; Freeman Powell, D; Ellis, D; Klapper, P; Scanlon, S; Higgins, S; Vivancos, R

    2016-09-01

    The burden of disease relating to undiagnosed HIV infection is significant in the UK. BHIVA (British HIV Association) recommends population screening in high prevalence areas, expanding outside traditional antenatal/GUM settings. RUClear 2011-12 piloted expanding HIV testing outside traditional settings using home-sampling kits (dry-blood-spot testing) ordered online. Greater Manchester residents (≥age 16) could request testing via an established, online chlamydia testing service (www.ruclear.co.uk). Participant attitudes towards this new service were assessed. Qualitative methods (thematic analysis) were used to analyse free-text data submitted by participants via hard copy questionnaires issued in all testing kits. 79.9% (2447/3062) participants completed questionnaires, of which 30.9% (756/2447) provided free-text data. Participants overwhelmingly supported the service, valuing particularly accessibility and convenience, allowing individuals to order tests any time of day and self-sample comfortably at home; avoiding the invasive nature of venipuncture and avoiding the need for face-to-face interaction with health services. The pilot was also clinically and cost-effective. Testing via home-sampling kits ordered online (dry-blood-spot testing) was felt to be an acceptable and convenient method for accessing a HIV test. Many individuals undertook HIV testing where they would otherwise not have been tested at all. Expansion of similar services may increase the uptake of HIV testing. © The Author 2015. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. Evaluation of Commercially Available Chikungunya Virus Immunoglobulin M Detection Assays

    PubMed Central

    Johnson, Barbara W.; Goodman, Christin H.; Holloway, Kimberly; de Salazar, P. Martinez; Valadere, Anne M.; Drebot, Michael A.

    2016-01-01

    Commercial chikungunya virus (CHIKV)–specific IgM detection kits were evaluated at the Centers for Disease Control and Prevention (CDC), the Public Health Agency of Canada National Microbiology Laboratory, and the Caribbean Public Health Agency (CARPHA). The Euroimmun Anti-CHIKV IgM ELISA kit had ≥ 95% concordance with all three reference laboratory results. The limit of detection for low CHIK IgM+ samples, as measured by serial dilution of seven sera up to 1:12,800 ranged from 1:800 to 1:3,200. The Euroimmun IIFT kit evaluated at CDC and CARPHA performed well, but required more retesting of equivocal results. The InBios CHIKjj Detect MAC-ELISA had 100% and 98% concordance with CDC and CARPHA results, respectively, and had equal sensitivity to the CDC MAC-ELISA to 1:12,800 dilution in serially diluted samples. The Abcam Anti-CHIKV IgM ELISA had high performance at CARPHA, but at CDC, performance was inconsistent between lots. After replacement of the biotinylated IgM antibody controls with serum containing CHIKV-specific IgM and additional quality assurance/control measures, the Abcam kit was rereleased and reevaluated at CDC. The reformatted Abcam kit had 97% concordance with CDC results and limit of detection of 1:800 to 1:3,200. Two rapid tests and three other CHIKV MAC-ELISAs evaluated at CDC had low sensitivity, as the CDC CHIKV IgM in-house positive controls were below the level of detection. In conclusion, laboratories have options for CHIKV serological diagnosis using validated commercial kits. PMID:26976887

  12. Comparison of Multiplex Suspension Array Large-Panel Kits for Profiling Cytokines and Chemokines in Rheumatoid Arthritis Patients

    PubMed Central

    Khan, Imran H.; Krishnan, V.V.; Ziman, Melanie; Janatpour, Kim; Wun, Ted; Luciw, Paul A.; Tuscano, Joseph

    2015-01-01

    Background Multiplex analysis allows measurements of a large number of analytes simultaneously in each sample. Based on the Luminex multiplex technology (xMAP), kits for measuring multiple cytokines and chemokines (immunomodulators) are commercially available and are useful in investigations on inflammatory diseases. This study evaluated four multiplex kits (Bio-Plex, LINCOplex, Fluorokine, and Beadlyte) that contained 27, 29, 20 and 22 analytes each, respectively, for the analysis of immunomodulators in plasma of rheumatoid arthritis (RA) patients who underwent treatment with antibody against CD20 (rituximab), a B-cell reductive therapy. Methods Multiplex kits were tested on serial plasma samples obtained from six RA patients at baseline and multiple time points (3, 6, and 9 months) post-treatment with rituximab. The RA patients included in this study had previously failed therapy with disease modifying anti-arthritis drugs (DMARD) and treatment with anti-TNFα antibody (infliximab). Results Computer modeling and hierarchical cluster analysis of the multiplex data allowed a comparison of the performance of multiplex assay kits and revealed profiles of immunomodulators in the RA patients. Conclusions In plasma of RA patients who appeared to have benefited from rituximab treatment the profile of significantly elevated immunomodulators by at least two of the three kits (BioPlex, LINCOplex, Beadlyte), is as follows: IL-12p70, Eotaxin, IL-4, TNFα, Il-9, IL-1β, IFNγ, IL-10, IL-6, and IL-13. Immunomodulator profiling by multiplex analysis may provide useful plasma biomarkers for monitoring response to B-cell reductive therapy in RA patients. PMID:18823005

  13. NextGen Home Sperm Banking Kit: Outcomes of Offsite vs Onsite Collection--Preliminary Findings.

    PubMed

    Agarwal, Ashok; Sharma, Reecha; Gupta, Sajal; Sharma, Rakesh

    2015-06-01

    To compare cryosurvival rates between remote collections with NextGen kit (offsite) and onsite collection of semen samples from infertile men and those with cancer. Prefreeze and post-thaw sperm motility, total motile sperm, and percent cryosurvival rates were compared between samples collected from infertile men onsite at the Andrology Center (n = 10) and samples collected from infertile patients at home (offsite; n = 9), which were shipped by NextGen to our laboratory. A second group (n = 17) consisted of 10 semen samples from cancer patients collected onsite, which were compared with 7 semen samples from cancer patients shipped by the NextGen. All semen samples were assessed within 18 hours of collection. In the infertile men, percent cryosurvival rates were similar with NextGen compared with those of onsite collection (53.14 ± 28.9% vs 61.90 ± 20.46%; P = .51). Similarly, in the cancer patients, all 4 parameters were comparable between the onsite and NextGen. Cryosurvival rates were also similar between NextGen compared with those of onsite collection (52.71 ± 20.37% vs 58.90 ± 22.68%; P = .46). Cancer patients can bank sperm as effectively as men banking for infertility reasons using the NextGen kit. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. [Application of DNA extraction kit, 'GM quicker' for detection of genetically modified soybeans].

    PubMed

    Sato, Noriko; Sugiura, Yoshitsugu; Tanaka, Toshitsugu

    2012-01-01

    Several DNA extraction methods have been officially introduced to detect genetically modified soybeans, but the choice of DNA extraction kits depend on the nature of the samples, such as grains or processed foods. To overcome this disadvantage, we examined whether the GM quicker kit is available for both grains and processed foods. We compared GM quicker with four approved DNA extraction kits in respect of DNA purity, copy numbers of lectin gene, and working time. We found that the DNA quality of GM quicker was superior to that of the other kits for grains, and the procedure was faster. However, in the case of processed foods, GM quicker was not superior to the other kits. We therefore investigated an unapproved GM quicker 3 kit, which is available for DNA extraction from processed foods, such as tofu and boiled soybeans. The GM quicker 3 kit provided good DNA quality from both grains and processed foods, so we made a minor modification of the GM quicker-based protocol that was suitable for processed foods, using GM quicker and its reagents. The modified method enhanced the performance of GM quicker with processed foods. We believe that GM quicker with the modified protocol is an excellent tool to obtain high-quality DNA from grains and processed foods for detection of genetically modified soybeans.

  15. SURVEY OF GROUND, SURFACE, AND POTABLE WATERS FOR THE PRESENCE OF LEGIONELLA SPECIES BY ENVIROAMP PCR LEGIONELLA KIT, CULTURE, AND IMMUNOFLUORESCENT STAINING

    EPA Science Inventory

    A total of 116 samples from numerous aquatic sources including water from faucets, showerheads, dental units, fire sprinklers, and surface waters were examined for the presence of Legionella by the EnviroAmp Legionella PCR kit, culture on BCYEx, or direct fluorescent antibody (DF...

  16. Acute Pancreatitis as a Model to Predict Transition of Systemic Inflammation to Organ Failure in Trauma and Critical Illiness

    DTIC Science & Technology

    2015-10-01

    of the samples. Table 1. Characteristics of common filters suitable for use with the LIVE/DEAD® Viability Kit Omega Filters* Chroma Filters* Notes...www.omegafilters.com). Chroma filters are supplied by Chroma Technology Corp. (www.chroma.com). LIVE/DEAD® Viability/Cytotoxicity Kit 3 4.2 Incubate the cells

  17. Development of an RNA-based kit for easy generation of TCR-engineered lymphocytes to control T-cell assay performance.

    PubMed

    Bidmon, Nicole; Kind, Sonja; Welters, Marij J P; Joseph-Pietras, Deborah; Laske, Karoline; Maurer, Dominik; Hadrup, Sine Reker; Schreibelt, Gerty; Rae, Richard; Sahin, Ugur; Gouttefangeas, Cécile; Britten, Cedrik M; van der Burg, Sjoerd H

    2018-07-01

    Cell-based assays to monitor antigen-specific T-cell responses are characterized by their high complexity and should be conducted under controlled conditions to lower multiple possible sources of assay variation. However, the lack of standard reagents makes it difficult to directly compare results generated in one lab over time and across institutions. Therefore TCR-engineered reference samples (TERS) that contain a defined number of antigen-specific T cells and continuously deliver stable results are urgently needed. We successfully established a simple and robust TERS technology that constitutes a useful tool to overcome this issue for commonly used T-cell immuno-assays. To enable users to generate large-scale TERS, on-site using the most commonly used electroporation (EP) devices, an RNA-based kit approach, providing stable TCR mRNA and an optimized manufacturing protocol were established. In preparation for the release of this immuno-control kit, we established optimal EP conditions on six devices and initiated an extended RNA stability study. Furthermore, we coordinated on-site production of TERS with 4 participants. Finally, a proficiency panel was organized to test the unsupervised production of TERS at different laboratories using the kit approach. The results obtained show the feasibility and robustness of the kit approach for versatile in-house production of cellular control samples. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  18. The Qiagen Investigator® Quantiplex HYres as an alternative kit for DNA quantification.

    PubMed

    Frégeau, Chantal J; Laurin, Nancy

    2015-05-01

    The Investigator® Quantiplex HYres kit was evaluated as a potential replacement for dual DNA quantification of casework samples. This kit was determined to be highly sensitive with a limit of quantification and limit of detection of 0.0049ng/μL and 0.0003ng/μL, respectively, for both human and male DNA, using full or half reaction volumes. It was also accurate in assessing the amount of male DNA present in 96 mock and actual casework male:female mixtures (various ratios) processed in this exercise. The close correlation between the male/human DNA ratios expressed in percentages derived from the Investigator® Quantiplex HYres quantification results and the male DNA proportion calculated in mixed AmpFlSTR® Profiler® Plus or AmpFlSTR® Identifiler® Plus profiles, using the Amelogenin Y peak and STR loci, allowed guidelines to be developed to facilitate decisions regarding when to submit samples to Y-STR rather than autosomal STR profiling. The internal control (IC) target was shown to be more sensitive to inhibitors compared to the human and male DNA targets included in the Investigator® Quantiplex HYres kit serving as a good quality assessor of DNA extracts. The new kit met our criteria of enhanced sensitivity, accuracy, consistency, reliability and robustness for casework DNA quantification. Crown Copyright © 2015. Published by Elsevier Ireland Ltd. All rights reserved.

  19. Evaluation of Immunomagnetic Separation for Recovery of Infectious Cryptosporidium parvum Oocysts from Environmental Samples

    PubMed Central

    Rochelle, Paul A.; De Leon, Ricardo; Johnson, Anne; Stewart, Mic H.; Wolfe, Roy L.

    1999-01-01

    Two commercial immunomagnetic separation (IMS) kits for Cryptosporidium were compared for recovery of oocysts from environmental samples. Oocyst recovery efficiencies with the Dynal and Crypto-Scan kits ranged from 62 to 100% and 34 to 74%, respectively, for seeded environmental water concentrates (turbidity of 210 to 11,480 nephelometric turbidity units). Recovery efficiencies were dependent on the mechanism of agitation during the magnetic capture procedure. An assay combining in vitro cell culture and reverse transcriptase PCR demonstrated that oocysts recovered by IMS retained their infectivity. PMID:9925626

  20. [Evaluation of Wondfo Rapid Diagnostic Kit for detecting Plasmodium ovale and analysis of influencing factors].

    PubMed

    Feng, Tang; Jian-Xia, Tang; Feng, Lu; Sui, Xu; Ya-Ping, Gu; De-Sheng, Tong; Guo-Ding, Zhu; Hai-Yong, Hua; Hua-Yun, Zhou; Jun, Cao

    2016-03-21

    To evaluate the Wondfo Rapid Diagnostic Kit (Pf-LDH/Pan -pLDH) for detecting Plasmodium ovale and analyze the influence of parasitaemia, concentration and polymorphism of pLDH on the performances. A total of 100 blood samples from P. ovale patients confirmed by PCR were detected with the Wondfo Rapid Diagnostic Kit according to the manufacturers'instructions. The parasitaemia was determined by the microscopic examination. The concentration of pLDH was measured by ELISA tests. The LDH gene of P. ovale was amplified by PCR and sequenced. The influence of these three factors on the positive rate was analyzed. The overall positive rate of Wondfo Rapid Diagnostic Kit was 70.0% (70/100). The positive rate was 27.3% for the samples with parasitaemia ≤ 500 parasites/μl and reached 75.0%-75.4% when parasitaemia > 500 parasites/μl. The positive rate was 6.7% for samples with a low pLDH concentration ( A values ≤ 0.100) and reached 95.1%-100% at a high pLDH concentration ( A values > 0.100). The results of sequence analysis indicated that all the samples could be divided into 2 types, P. o. curtisi and P. o. wallikeri . The gene homology of LDH between 2 types was 97%. There were 24 single nucleotide polymorphism (s) (SNPs) between 2 types, while only 3 SNPs were non-synonymous mutations. The homology of LDH amino acid sequences between 2 types was 99%; only 3 amino acids were different. The positive rates for P. o. curtisi and P. o. wallikeri were 73.1% (38/52) and 66.7% (32/48) respectively; there was no statistically significant difference ( P > 0.05). The Wondfo Rapid Diagnostic Kit (Pf-LDH/Pan-pLDH) performs better than most of the similar products for the detection of P. ovale , and the positive rates are closely related to the parasitaemia and concentration of pLDH, while no related to the polymorphism of pLDH gene.

  1. Evaluation of the Coca-Cola company travel health kit.

    PubMed

    Harper, Lynne A; Bettinger, Julie; Dismukes, Roberta; Kozarsky, Phyllis E

    2002-01-01

    The Coca-Cola travel health kit has been used for about one decade for international travelers and required evaluation to see if the items contained were appropriate for the employees. Two hundred thirty-four travelers were sampled and filled out a voluntary survey including questions about demographic information, travel history, and usage and value of the contents of the travel health kit. One hundred eighty-one surveys were returned; 65% of the respondents were male, and the majority of travelers were between the ages of 36 and 45 years. The most useful items were analgesics and medications used for gastrointestinal problems. In general, the items identified as being the least useful were those requiring specialized use by a medical practitioner, such as needles and syringes. Suggestions of items to be added to the kit included vitamins, cough drops, sleep aids, and eye drops. A surprising result that Coca-Cola employees expressed the desire for brand name rather than generic items. Evaluation of the Coca-Cola Company travel health kit revealed it to be very useful to most corporate travelers. Suggestions that were made will be taken into consideration in designing a new kit, and consideration is being given to whether a basic travel health kit should be provided to which travelers can add other items depending on their personal needs.

  2. [Comparison between the LightCycler CMV Quant Kit (Roche Diagnostics) with a standardized in-house Taqman assay for cytomegalovirus blood viral load quantification].

    PubMed

    Alain, S; Lachaise, V; Hantz, S; Denis, F

    2010-04-01

    The broad use of cytomegalovirus (CMV) viral load quantification in blood to follow immunosuppressed patients need standardized assays. Choice of whole blood allows follow-up for several viruses and simplifies pretreatment and storage of samples. We therefore evaluated the LightCycler CMV Quant Kit (Roche Diagnostics) assay on whole blood after a manual extraction (High Pure viral nucleic acid kit, Roche Diagnostics), using as a reference an in-house Taqman assay (LC1UL83) which has been validated in various clinical situations. A panel obtained by serial dilutions of a virion stock in CMV whole blood, a commercial plasma quality control (VQC, Argène, France) crude or diluted in whole blood, infected cells extracts and 46 clinical samples from transplanted patients were tested simultaneously by both techniques. For plasma quality controls, both PCR assays are correlated VQC (R(2)=0.93). On whole blood or infected cells dilutions, correlation shows an overestimation by the LC1UL83 assay (mean 1.2 log copies/ml) over 3 log though R(2)=0.94. Results with CMV Quant Kit are closer to expected values. Results on clinical samples are close to quality controls with a lower variation of quantification (0.76 log copies/ml). CMV Quant Kit performs well when compared with a clinically validated PCR. Quality control results showed discrepancies between plasma and whole blood, demonstrating the need for whole blood standardized panels to compare the methods. This underlines the need to follow a patient with the same technique during his follow-up. Copyright 2009 Elsevier Masson SAS. All rights reserved.

  3. Multicentric comparative assessment of the bio-evolution Toxoplasma gondii detection kit with eight laboratory-developed PCR assays for molecular diagnosis of congenital toxoplasmosis.

    PubMed

    Filisetti, Denis; Sterkers, Yvon; Brenier-Pinchart, Marie-Pierre; Cassaing, Sophie; Dalle, Frédéric; Delhaes, Laurence; Pelloux, Hervé; Touafek, Fériel; Varlet-Marie, Emmanuelle; Yera, Hélène; Candolfi, Ermano; Bastien, Patrick

    2015-01-01

    The detection of Toxoplasma gondii in amniotic fluid is an essential tool for the prenatal diagnosis of congenital toxoplasmosis and is currently essentially based on the use of PCR. Although some consensus is emerging, this molecular diagnosis suffers from a lack of standardization and an extreme diversity of laboratory-developed methods. Commercial kits for the detection of T. gondii by PCR were recently developed and offer certain advantages; however, they must be assessed in comparison with optimized reference PCR assays. The present multicentric study aimed to compare the performances of the Bio-Evolution T. gondii detection kit and laboratory-developed PCR assays set up in eight proficient centers in France. The study compared 157 amniotic fluid samples and found concordances of 99% and 100% using 76 T. gondii-infected samples and 81 uninfected samples, respectively. Moreover, taking into account the classification of the European Research Network on Congenital Toxoplasmosis, the overall diagnostic sensitivity of all assays was identical and calculated to be 86% (54/63); specificity was 100% for all assays. Finally, the relative quantification results were in good agreement between the kit and the laboratory-developed assays. The good performances of this commercial kit are probably in part linked to the use of a number of good practices: detection in multiplicate, amplification of the repetitive DNA target rep529, and the use of an internal control for the detection of PCR inhibitors. The only drawbacks noted at the time of the study were the absence of uracil-N-glycosylase and small defects in the reliability of the production of different reagents. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  4. Multicentric Comparative Assessment of the Bio-Evolution Toxoplasma gondii Detection Kit with Eight Laboratory-Developed PCR Assays for Molecular Diagnosis of Congenital Toxoplasmosis

    PubMed Central

    Filisetti, Denis; Sterkers, Yvon; Brenier-Pinchart, Marie-Pierre; Cassaing, Sophie; Dalle, Frédéric; Delhaes, Laurence; Pelloux, Hervé; Touafek, Fériel; Varlet-Marie, Emmanuelle; Yera, Hélène; Candolfi, Ermano

    2014-01-01

    The detection of Toxoplasma gondii in amniotic fluid is an essential tool for the prenatal diagnosis of congenital toxoplasmosis and is currently essentially based on the use of PCR. Although some consensus is emerging, this molecular diagnosis suffers from a lack of standardization and an extreme diversity of laboratory-developed methods. Commercial kits for the detection of T. gondii by PCR were recently developed and offer certain advantages; however, they must be assessed in comparison with optimized reference PCR assays. The present multicentric study aimed to compare the performances of the Bio-Evolution T. gondii detection kit and laboratory-developed PCR assays set up in eight proficient centers in France. The study compared 157 amniotic fluid samples and found concordances of 99% and 100% using 76 T. gondii-infected samples and 81 uninfected samples, respectively. Moreover, taking into account the classification of the European Research Network on Congenital Toxoplasmosis, the overall diagnostic sensitivity of all assays was identical and calculated to be 86% (54/63); specificity was 100% for all assays. Finally, the relative quantification results were in good agreement between the kit and the laboratory-developed assays. The good performances of this commercial kit are probably in part linked to the use of a number of good practices: detection in multiplicate, amplification of the repetitive DNA target rep529, and the use of an internal control for the detection of PCR inhibitors. The only drawbacks noted at the time of the study were the absence of uracil-N-glycosylase and small defects in the reliability of the production of different reagents. PMID:25339393

  5. Concurrent Isolation of 3 Distinct Cardiac Stem Cell Populations From a Single Human Heart Biopsy.

    PubMed

    Monsanto, Megan M; White, Kevin S; Kim, Taeyong; Wang, Bingyan J; Fisher, Kristina; Ilves, Kelli; Khalafalla, Farid G; Casillas, Alexandria; Broughton, Kathleen; Mohsin, Sadia; Dembitsky, Walter P; Sussman, Mark A

    2017-07-07

    The relative actions and synergism between distinct myocardial-derived stem cell populations remain obscure. Ongoing debates on optimal cell population(s) for treatment of heart failure prompted implementation of a protocol for isolation of multiple stem cell populations from a single myocardial tissue sample to develop new insights for achieving myocardial regeneration. Establish a robust cardiac stem cell isolation and culture protocol to consistently generate 3 distinct stem cell populations from a single human heart biopsy. Isolation of 3 endogenous cardiac stem cell populations was performed from human heart samples routinely discarded during implantation of a left ventricular assist device. Tissue explants were mechanically minced into 1 mm 3 pieces to minimize time exposure to collagenase digestion and preserve cell viability. Centrifugation removes large cardiomyocytes and tissue debris producing a single cell suspension that is sorted using magnetic-activated cell sorting technology. Initial sorting is based on tyrosine-protein kinase Kit (c-Kit) expression that enriches for 2 c-Kit + cell populations yielding a mixture of cardiac progenitor cells and endothelial progenitor cells. Flowthrough c-Kit - mesenchymal stem cells are positively selected by surface expression of markers CD90 and CD105. After 1 week of culture, the c-Kit + population is further enriched by selection for a CD133 + endothelial progenitor cell population. Persistence of respective cell surface markers in vitro is confirmed both by flow cytometry and immunocytochemistry. Three distinct cardiac cell populations with individualized phenotypic properties consistent with cardiac progenitor cells, endothelial progenitor cells, and mesenchymal stem cells can be successfully concurrently isolated and expanded from a single tissue sample derived from human heart failure patients. © 2017 American Heart Association, Inc.

  6. Development of an add-on kit for scanning confocal microscopy (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Guo, Kaikai; Zheng, Guoan

    2017-03-01

    Scanning confocal microscopy is a standard choice for many fluorescence imaging applications in basic biomedical research. It is able to produce optically sectioned images and provide acquisition versatility to address many samples and application demands. However, scanning a focused point across the specimen limits the speed of image acquisition. As a result, scanning confocal microscope only works well with stationary samples. Researchers have performed parallel confocal scanning using digital-micromirror-device (DMD), which was used to project a scanning multi-point pattern across the sample. The DMD based parallel confocal systems increase the imaging speed while maintaining the optical sectioning ability. In this paper, we report the development of an add-on kit for high-speed and low-cost confocal microscopy. By adapting this add-on kit to an existing regular microscope, one can convert it into a confocal microscope without significant hardware modifications. Compared with current DMD-based implementations, the reported approach is able to recover multiple layers along the z axis simultaneously. It may find applications in wafer inspection and 3D metrology of semiconductor circuit. The dissemination of the proposed add-on kit under $1000 budget could also lead to new types of experimental designs for biological research labs, e.g., cytology analysis in cell culture experiments, genetic studies on multicellular organisms, pharmaceutical drug profiling, RNA interference studies, investigation of microbial communities in environmental systems, and etc.

  7. Detection of Listeria monocytogenes in ready-to-eat food by Step One real-time polymerase chain reaction.

    PubMed

    Pochop, Jaroslav; Kačániová, Miroslava; Hleba, Lukáš; Lopasovský, L'ubomír; Bobková, Alica; Zeleňáková, Lucia; Stričík, Michal

    2012-01-01

    The aim of this study was to follow contamination of ready-to-eat food with Listeria monocytogenes by using the Step One real time polymerase chain reaction (PCR). We used the PrepSEQ Rapid Spin Sample Preparation Kit for isolation of DNA and MicroSEQ® Listeria monocytogenes Detection Kit for the real-time PCR performance. In 30 samples of ready-to-eat milk and meat products without incubation we detected strains of Listeria monocytogenes in five samples (swabs). Internal positive control (IPC) was positive in all samples. Our results indicated that the real-time PCR assay developed in this study could sensitively detect Listeria monocytogenes in ready-to-eat food without incubation.

  8. Effect of blanching treatments on antioxidant activity of frozen green capsicum (Capsicum annuum L. var bell pepper) using radical scavenging activity (DPPH) assay

    NASA Astrophysics Data System (ADS)

    Azizzuddin, Norafida; Abdullah, Aminah

    2016-11-01

    Blanching treatments are needed to deactivate enzymes in frozen vegetables. Antioxidant activity using DPPH radical scavenging activity assay were evaluated in steaming, boiling water, and microwave blanching at different temperature, time and microwave power level on frozen green capsicum. Green capsicum was chosen for frozen treatment compared to other capsicum with different maturity index because of the firm texture. The objective of this study was to compare the antioxidant activity of frozen green capsicum between conventional and Oxi Count Kit® assay for DPPH radical scavenging activity. Results showed frozen green capsicum blanched using microwave at high level/90 seconds (sample J) contained higher level of DPPH in both conventional method and Oxi Count Kit® compared to other treatments. However, there were no significant differences between sample J and fresh sample (sample A). Overall, the sequences from highest to lowest in blanching treatments for both DPPH conventional method, and DPPH Oxi Count Kit® were J (microwave high level/90 seconds) > A (Fresh) > H (Microwave Medium Level/120 seconds) > D (Boiling Water 80°C/150 seconds) > K (Microwave High Level/120 seconds) > I (Microwave Medium Level/150 seconds) > F (Microwave Low Level/150 seconds)> B (Steam 100°C/150 seconds) > E (Boiling Water 100°C /120 seconds) > G (Microwave Low Level /180 seconds)> C (Steam 100°C/180 seconds). Almost all frozen green capsicum samples showed no significant differences for comparison between test using DPPH conventional method and Oxi Count Kit®. Frozen storage for 0, and 3rd months showed no significant differences which indicate no changes on antioxidant activity during frozen storage at -18°C.

  9. Audit of lymphadenectomy in lung cancer resections using a specimen collection kit and checklist.

    PubMed

    Osarogiagbon, Raymond U; Sareen, Srishti; Eke, Ransome; Yu, Xinhua; McHugh, Laura M; Kernstine, Kemp H; Putnam, Joe B; Robbins, Edward T

    2015-02-01

    Audits of operative summaries and pathology reports reveal wide discordance in identifying the extent of lymphadenectomy performed (the communication gap). We tested the ability of a prelabeled lymph node specimen collection kit and checklist to narrow the communication gap between operating surgeons, pathologists, and auditors of surgeons' operation notes. We conducted a prospective single cohort study of lung cancer resections performed with a lymph node collection kit from November 2010 to January 2013. We used the kappa statistic to compare surgeon claims on a checklist of lymph node stations harvested intraoperatively with pathology reports and an independent audit of surgeons' operative summaries. Lymph node collection procedures were classified into four groups based on the anatomic origin of resected lymph nodes: mediastinal lymph node dissection, systematic sampling, random sampling, and no sampling. From the pathology reports, 73% of 160 resections had a mediastinal lymph node dissection or systematic sampling procedure, 27% had random sampling. The concordance with surgeon claims was 80% (kappa statistic 0.69, 95% confidence interval: 0.60 to 0.79). Concordance between independent audits of the operation notes and either the pathology report (kappa 0.14, 95% confidence interval: 0.04 to 0.23) or surgeon claims (kappa 0.09, 95% confidence interval: 0.03 to 0.22) was poor. A prelabeled specimen collection kit and checklist significantly narrowed the communication gap between surgeons and pathologists in identifying the extent of lymphadenectomy. Audit of surgeons' operation notes did not accurately reflect the procedure performed, bringing its value for quality improvement work into question. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. A method suitable for DNA extraction from humus-rich soil.

    PubMed

    Miao, Tianjin; Gao, Song; Jiang, Shengwei; Kan, Guoshi; Liu, Pengju; Wu, Xianming; An, Yingfeng; Yao, Shuo

    2014-11-01

    A rapid and convenient method for extracting DNA from soil is presented. Soil DNA is extracted by direct cell lysis in the presence of EDTA, SDS, phenol, chloroform and isoamyl alcohol (3-methyl-1-butanol) followed by precipitation with 2-propanol. The extracted DNA is purified by modified DNA purification kit and DNA gel extraction kit. With this method, DNA extracted from humus-rich dark brown forest soil was free from humic substances and, therefore, could be used for efficient PCR amplification and restriction digestion. In contrast, DNA sample extracted with the traditional CTAB-based method had lower yield and purity, and no DNA could be extracted from the same soil sample with a commonly-used commercial soil DNA isolation kit. In addition, this method is time-saving and convenient, providing an efficient choice especially for DNA extraction from humus-rich soils.

  11. The Development and Use of Internal Amplification Controls (IACs) with DNA Profiling Kits for Forensic DNA Analysis.

    PubMed

    Zahra, Nathalie; Goodwin, William

    2016-01-01

    Biological samples recovered for forensic investigations are often degraded and/or have low amounts of DNA; in addition, in some instances the samples may be contaminated with chemicals that can act as PCR inhibitors. As a consequence this can make interpretation of the results challenging with the possibility of having partial profiles and false negative results. Because of the impact of DNA analysis on forensic investigations, it is important to monitor the process of DNA profiling, in particular the amplification reaction. In this chapter we describe a method for the in-house generation and use of internal amplification controls (IACs) with DNA profiling kits to monitor the success of the PCR proces. In the example we show the use of the SGM Plus® kit. These controls can also be used to aid the interpretation of the DNA profile.

  12. Standardisation of a novel sperm banking kit - NextGen(®) - to preserve sperm parameters during shipment.

    PubMed

    Agarwal, A; Sharma, R; Singh, A; Gupta, S; Sharma, R

    2016-08-01

    Many male patients diagnosed with cancer are within their reproductive years. These men are advised to freeze their spermatozoa prior to the start of cancer treatment. Very often, sperm banking facilities may not be readily available and patients may be required to travel to distant sperm bank centres. Our objective was to design and standardise a remote home shipping sperm kit that allows patients to collect a semen sample at home and ship it overnight to a sperm bank. A total of 21 semen samples and two transport media (refrigeration media and human tubal fluid) and five different combinations of ice packs were tested for maintaining desired shipping temperature. Ten semen samples were assessed for pre- and post-shipment changes in sperm motility, membrane integrity, total motile spermatozoa and recovery of motile spermatozoa. Even though motility, membrane integrity and total motile spermatozoa declined both in samples examined under simulated shipped conditions and in overnight-shipped samples, the observed motility and total motile spermatozoa were adequate for use with assisted reproductive techniques. Using refrigeration media, cooling sleeve and ice packs, adequate sperm motility can be maintained utilising NextGen(®) kit and these spermatozoa can be used for procreation utilising ART techniques such as intracytoplasmic sperm injection. © 2015 Blackwell Verlag GmbH.

  13. [The validation of kit of reagents for quantitative detection of DNA of human cytomegalovirus in biological material using polymerase chain reaction technique in real time operation mode].

    PubMed

    Sil'veĭstrova, O Iu; Domonova, É A; Shipulina, O Iu

    2014-04-01

    The validation of kit of reagents destined to detection and quantitative evaluation of DNA of human cytomegalovirus in biological material using polymerase chain reaction technique in real time operation mode was implemented. The comparison was made against international WHO standard--The first WHO international standard for human cytomegalovirus to implement measures the kit of reagents "AmpliSens CMV-screen/monitor-FL" and standard sample of enterprise DNA HCMV (The central research institute of epidemiology of Rospotrebnadzor) was applied. The fivefold dilution of international WHO standard and standard sample of enterprise were carried out in concentrations of DNA HCMV from 106 to 102. The arrangement of polymerase chain reaction and analysis of results were implemented using programed amplifier with system of detection of fluorescent signal in real-time mode "Rotor-Gene Q" ("Qiagen", Germany). In the total of three series of experiments, all stages of polymerase chain reaction study included, the coefficient of translation of quantitative evaluation of DNA HCMV from copy/ml to ME/ml equal to 0.6 was introduced for this kit of reagents.

  14. A Lateral Flow Rapid Test for Human Toxocariasis Developed Using Three Toxocara canis Recombinant Antigens.

    PubMed

    Yunus, Muhammad Hafiznur; Tan Farrizam, Siti Naqiuyah; Abdul Karim, Izzati Zahidah; Noordin, Rahmah

    2018-01-01

    Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara- positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.

  15. Diagnosis of Acute Q Fever by Detection of Coxiella burnetii DNA using Real-Time PCR, Employing a Commercial Genesig Easy Kit

    PubMed Central

    Pradeep, Jothimani; Ambroise, Stanley; Gunasekaran, Dhandapany

    2017-01-01

    Introduction Query (Q) fever is an important zoonosis and a cause of concern for humans, due to the potential bioterrorism threat posed by the causative agent, Coxiella burnetii. Because of the danger of contracting the illness, isolation attempts are seldom made. Serological and molecular diagnostic tests are the main option. Aim To study the prevalence of acute Q fever in Puducherry and surrounding districts of Tamil Nadu, India, employing a new commercial Real-Time Polymerase Chain Reaction (RT-PCR) kit and confirming it by the gold standard Immunofluorescence Assay (IFA). Materials and Methods Acute phase blood samples from 72 consecutive febrile patients and 24 healthy individuals were included in this prospective study. DNA was extracted from the buffy coats and preserved at -80°C. Detection of C. burnetii was carried out employing a commercial Real-Time PCR kit. Serum samples were tested for IgM (Phase I+II) and IgG (Phase I+II) by QM-120 and QG-120, Coxiella burnetii IFA Fuller Laboratories, California, USA. Sensitivity, Specificity, Positive Predictive Value (PPV) and Negative Predictive Value (NPV) were calculated keeping IFA as the reference. Results Presumptive diagnosis of acute Q fever was made in two febrile patients by the Genesig Easy kit (2.78%). In addition to these two PCR positive cases, one more patient was positive for both Phase II IgM and Phase II IgG antibodies by the gold standard IFA. All 24 healthy controls were negative for Q fever by both PCR and IFA. The sensitivity, specificity, NPV and PPV for Genesig Easy kit PCR were: 66.67%, 100%, 100% and 98.57 % respectively against IFA as the reference. Conclusion The true prevalence of Q fever in India and other developing countries is poorly understood, owing to the difficulties in the diagnosis of this infection. Since molecular diagnostic tests have good specificity and are mandated for confirmation of single acute samples, validation of commercial Q fever PCR kits is the need of the hour. Genesig Easy kit in our hands was found to be reliable with the moderate sensitivity and high specificity. Performing both PCR (with acute specimens) and IFA (with paired sera) would be ideal for Q fever diagnosis. PMID:29207703

  16. Highly efficient nuclear DNA typing of the World War II skeletal remains using three new autosomal short tandem repeat amplification kits with the extended European Standard Set of loci

    PubMed Central

    Zupanič Pajnič, Irena; Gornjak Pogorelc, Barbara; Balažic, Jože; Zupanc, Tomaž; Štefanič, Borut

    2012-01-01

    Aim To perform an efficiency study of three new amplification kits with the extended European Standard Set (ESS) of loci for autosomal short tandem repeat (STR) typing of skeletal remains excavated from the World War II mass graves in Slovenia. Methods In the beginning of the 2011, we analyzed 102 bones and teeth using the PowerPlex ESX 17 System (Promega), AmpFiSTR NGM PCR Amplification Kit (Applied Biosystems), and Investigator ESSplex Kit (Qiagen). We cleaned the bones and teeth, removed surface contamination, and ground them into a powder using liquid nitrogen. Prior to DNA isolation with Biorobot EZ1 (Qiagen), 0.5 g bone or tooth powder was decalcified. Nuclear DNA of the samples was quantified using real-time polymerase chain reaction. All three kits used the same extract with the amplification conditions recommended by the manufacturers. Results We extracted up to 131 ng DNA/g of powder from the bones and teeth. All three amplification kits showed very similar efficiency, since DNA typing was successful with all amplification kits in 101 out of 102 bones and teeth, which represents a 99% success rate. Conclusion The commercially available ESX 17, ESSplex, and NGM kits are highly reliable for STR typing of World War II skeletal remains with the DNA extraction method optimized in our laboratory. PMID:22351574

  17. Imatinib mesylate inhibits Leydig cell tumor growth: evidence for in vitro and in vivo activity.

    PubMed

    Basciani, Sabrina; Brama, Marina; Mariani, Stefania; De Luca, Gabriele; Arizzi, Mario; Vesci, Loredana; Pisano, Claudio; Dolci, Susanna; Spera, Giovanni; Gnessi, Lucio

    2005-03-01

    Leydig cell tumors are usually benign tumors of the male gonad. However, if the tumor is malignant, no effective treatments are currently available. Leydig cell tumors express platelet-derived growth factor (PDGF), kit ligand and their respective receptors, PDGFR and c-kit. We therefore evaluated the effects of imatinib mesylate (imatinib), a selective inhibitor of the c-kit and PDGFR tyrosine kinases, on the growth of rodent Leydig tumor cell lines in vivo and in vitro, and examined, in human Leydig cell tumor samples, the expression of activated PDGFR and c-kit and the mutations in exons of the c-kit gene commonly associated with solid tumors. Imatinib caused concentration-dependent decreases in the viability of Leydig tumor cell lines, which coincided with apoptosis and inhibition of proliferation and ligand-stimulated phosphorylation of c-kit and PDGFRs. Mice bearing s.c. allografts of a Leydig tumor cell line treated with imatinib p.o., had an almost complete inhibition of tumor growth, less tumor cell proliferation, increased apoptosis, and a lesser amount of tumor-associated mean vessel density compared with controls. No drug-resistant tumors appeared during imatinib treatment but tumors regrew after drug withdrawal. Human Leydig cell tumors showed an intense expression of the phosphorylated form of c-kit and a less intense expression of phosphorylated PDGFRs. No activating mutations in common regions of mutation of the c-kit gene were found. Our studies suggest that Leydig cell tumors might be a potential target for imatinib therapy.

  18. The National Problem of Untested Sexual Assault Kits (SAKs): Scope, Causes, and Future Directions for Research, Policy, and Practice.

    PubMed

    Campbell, Rebecca; Feeney, Hannah; Fehler-Cabral, Giannina; Shaw, Jessica; Horsford, Sheena

    2015-12-23

    Victims of sexual assault are often advised to have a medical forensic exam and sexual assault kit (SAK; also termed a "rape kit") to preserve physical evidence (e.g., semen, blood, and/or saliva samples) to aid in the investigation and prosecution of the crime. Law enforcement are tasked with submitting the rape kit to a forensic laboratory for DNA (deoxyribonucleic acid) analysis, which can be instrumental in identifying offenders in previously unsolved crimes, confirming identify in known-offender assaults, discovering serial rapists, and exonerating individuals wrongly accused. However, a growing number of media stories, investigative advocacy projects, and social science studies indicate that police are not routinely submitting SAKs for forensic testing, and instead rape kits are placed in evidence storage, sometimes for decades. This review article examines the growing national problem of untested rape kits by summarizing current research on the number of untested SAKs in the United States and exploring the underlying reasons why police do not submit this evidence for DNA testing. Recommendations for future research that can guide policy and practice are discussed. © The Author(s) 2015.

  19. Detection of genetically modified soybean in crude soybean oil.

    PubMed

    Nikolić, Zorica; Vasiljević, Ivana; Zdjelar, Gordana; Ðorđević, Vuk; Ignjatov, Maja; Jovičić, Dušica; Milošević, Dragana

    2014-02-15

    In order to detect presence and quantity of Roundup Ready (RR) soybean in crude oil extracted from soybean seed with a different percentage of GMO seed two extraction methods were used, CTAB and DNeasy Plant Mini Kit. The amplifications of lectin gene, used to check the presence of soybean DNA, were not achieved in all CTAB extracts of DNA, while commercial kit gave satisfactory results. Comparing actual and estimated GMO content between two extraction methods, root mean square deviation for kit is 0.208 and for CTAB is 2.127, clearly demonstrated superiority of kit over CTAB extraction. The results of quantification evidently showed that if the oil samples originate from soybean seed with varying percentage of RR, it is possible to monitor the GMO content at the first stage of processing crude oil. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Automated forensic DNA purification optimized for FTA card punches and identifiler STR-based PCR analysis.

    PubMed

    Tack, Lois C; Thomas, Michelle; Reich, Karl

    2007-03-01

    Forensic labs globally face the same problem-a growing need to process a greater number and wider variety of samples for DNA analysis. The same forensic lab can be tasked all at once with processing mixed casework samples from crime scenes, convicted offender samples for database entry, and tissue from tsunami victims for identification. Besides flexibility in the robotic system chosen for forensic automation, there is a need, for each sample type, to develop new methodology that is not only faster but also more reliable than past procedures. FTA is a chemical treatment of paper, unique to Whatman Bioscience, and is used for the stabilization and storage of biological samples. Here, the authors describe optimization of the Whatman FTA Purification Kit protocol for use with the AmpFlSTR Identifiler PCR Amplification Kit.

  1. miR-148b-3p functions as a tumor suppressor in GISTs by directly targeting KIT.

    PubMed

    Wang, Yu; Li, Jun; Kuang, Dong; Wang, Xiaoyan; Zhu, Yuanli; Xu, Sanpeng; Chen, Yaobing; Cheng, Henghui; Zhao, Qiu; Duan, Yaqi; Wang, Guoping

    2018-04-16

    Gain-of-function mutations and overexpression of KIT are characteristic features of gastrointestinal stromal tumor (GIST). Dysregulation in miRNA expression may lead to KIT overexpression and tumorigenesis. miRNA microarray analysis and real-time PCR were used to determine the miRNA expression profiles in a cohort of 69 clinical samples including 50 CD117 IHC+ /KIT mutation GISTs and 19 CD117 IHC- /wild-type GISTs. GO enrichment and KEGG pathway analyses were performed to reveal the predicted targets of the dysregulated miRNAs. Of the dysregulated miRNAs whose expression was inversely correlated with that of KIT miRNAs were predicted by bioinformatics analysis and confirmed by luciferase reporter assay. Cell counting kit-8 (CCK-8) and flow cytometry were used to measure the cell proliferation, cycle arrest and apoptosis. Wound healing and transwell assays were used to evaluate migration and invasion. A xenograft BALB/c nude mouse model was applied to investigate the tumorigenesis in vivo. Western blot and qRT-PCR were used to investigate the protein and mRNA levels of KIT and its downstream effectors including ERK, AKT and STAT3. Of the six miRNAs whose expression was inversely correlated with that of KIT, we found that miR-148b-3p was significantly downregulated in the CD117 IHC+ /KIT mutation GIST cohort. This miRNA was subsequently found to inhibit proliferation, migration and invasion of GIST882 cells. Mechanistically, miR-148b-3p was shown to regulate KIT expression through directly binding to the 3'-UTR of the KIT mRNA. Restoration of miR-148b-3p expression in GIST882 cells led to reduced expression of KIT and the downstream effectors proteins ERK, AKT and STAT3. However, overexpression of KIT reversed the inhibitory effect of miR-148b-3p on cell proliferation, migration and invasion. Furthermore, we found that reduced miR-148b-3p expression correlated with poor overall survival (OS) and disease-free survival (DFS) in GIST patients. miR-148b-3p functions as an important regulator of KIT expression and a potential prognostic biomarker for GISTs.

  2. Study protocol of the CHOiCE trial: a three-armed, randomized, controlled trial of home-based HPV self-sampling for non-participants in an organized cervical cancer screening program.

    PubMed

    Tranberg, Mette; Bech, Bodil Hammer; Blaakær, Jan; Jensen, Jørgen Skov; Svanholm, Hans; Andersen, Berit

    2016-11-03

    The effectiveness of cervical cancer screening programs is challenged by suboptimal participation and coverage. Offering cervico-vaginal self-sampling for human papillomavirus testing (HPV self-sampling) to non-participants can increase screening participation. However, the effect varies substantially among studies, especially depending on the approach used to offer HPV self-sampling. The present trial evaluates the effect on participation in an organized screening program of a HPV self-sampling kit mailed directly to the home of the woman or mailed to the woman's home on demand only, compared with the standard second reminder for regular screening. The CHOiCE trial is a parallel, randomized, controlled, open-label trial. It will include 9327 women aged 30-64 years who are living in the Central Denmark Region and who have not participated in cervical cancer screening after an invitation and one reminder. The women will be equally randomized into three arms: 1) Directly mailed a second reminder including a HPV self-sampling kit; 2) Mailed a second reminder offering a HPV self-sampling kit, to be ordered by e-mail, text message, phone, or through a webpage; and 3) Mailed a second reminder for a practitioner-collected sample (control group). The primary outcome will be the proportion of women in the intervention groups who participate by returning their HPV self-sampling kit or have a practitioner-collected sample compared with the proportion of women who have a practitioner-collected sample in the control group at 90 and 180 days after mail out of the second reminders. Per-protocol and intention-to-treat analyses will be performed. The secondary outcome will be the proportion of women with a positive HPV self-collected sample who attend follow-up testing at 30, 60, or 90 days after mail out of the results. The CHOiCE trial will provide strong and important evidence allowing us to determine if and how HPV self-sampling can be used to increase participation in cervical cancer screening. This trial therefore has the potential to improve prevention and reduce the number of deaths caused by cervical cancer. Current Controlled Trials NCT02680262 . Registered 10 February 2016.

  3. [Double-antigen sandwich ELISA for detecting Aspergillus fumigatus anti-Afmp1cr and Afmp2cr antibodies].

    PubMed

    Yang, Mei; Wang, Zhuoya; Hao, Wei; Wang, Yanfang; Huang, Li; Cai, Jianpiao; Jiang, Lingxiao; Che, Xiaoyan; Zhong, Xiaozhu; Yu, Nan

    2014-05-01

    To establish two double-antigen sandwich ELISA systems to detect anti-Afmp1cr and Afmp2cr antibodies of Aspergillus fumigatus. Recombinant Afmp1cr and Afmp2cr proteins of A.fumigatus expressed in Pichia pastoris were obtained. Double-antigen sandwich ELISA systems for detecting specific anti-Afmp1cr and anti-Afmp2cr antibodies were developed after chessboard titrating to determine the appropriate concentrations of the recombinant proteins and HRP-labeled proteins. The sensitivity of the assay was evaluated using serum samples of rabbits immunized with Afmp1cr and Afmp2cr. The specificity of the assay was evaluated by detecting serum samples from healthy donors and patients with other pathogenic fungal and baterial infections. The performance of the two ELISA kits was furthered evaluated using serum samples from patients with suspected Aspergillus infection. The established ELISA kits were capable of detecting anti-Afmp1cr and anti-Afmp2cr antibodies in immunized rabbit serum at the maximum dilutions of 800 and 3200, respectively. No cross-reactivity was observed in detecting serum from patients with other pathogenic fungal or bactetial infections. Both of the two kits yielded positive results in sera from two established Aspergillus-infected cases and a suspected case. Two antibody-capture ELISA kits were developed for the laboratory diagnosis of A.fumigatus infection and can be potentially useful in the clinical diagnosis of Aspergillosis infections.

  4. Roche/BIOTECON Diagnostics LightCycler foodproof L. monocytogenes detection kit in combination with ShortPrep foodproof II Kit. Performance-Tested Method 070401.

    PubMed

    Junge, Benjamin; Berghof-Jäger, Kornelia

    2006-01-01

    A method was developed for the detection of L. monocytogenes in food based on real-time polymerase chain reaction (PCR). This advanced PCR method was designed to reduce the time needed to achieve results from PCR reactions and to enable the user to monitor the amplification of the PCR product simultaneously, in real-time. After DNA isolation using the Roche/BIOTECON Diagnostics ShortPrep foodproof II Kit (formerly called Listeria ShortPrep Kit) designed for the rapid preparation of L. monocytogenes DNA for direct use in PCR, the real-time detection of L. monocytogenes DNA is performed by using the Roche/BIOTECON Diagnostics LightCycler foodproof L. monocytogenes Detection Kit. This kit provides primers and hybridization probes for sequence-specific detection, convenient premixed reagents, and different controls for reliable interpretation of results. For repeatability studies, 20 different foods, covering the 15 food groups recommended from the AOAC Research Institute (AOAC RI) for L. monocytogenes detection were analyzed: raw meats, fresh produce/vegetables, processed meats, seafood, egg and egg products, dairy (cultured/noncultured), spices, dry foods, fruit/juices, uncooked pasta, nuts, confectionery, pet food, food dyes and colorings, and miscellaneous. From each food 20, samples were inoculated with a low level (1-10 colony-forming units (CFU)/25 g) and 20 samples with a high level (10-50 CFU/25 g) of L. monocytogenes. Additionally, 5 uninoculated samples were prepared from each food. The food samples were examined with the test kits and in correlation with the cultural methods according to U.S. Food and Drug Administration (FDA) Bacteriological Analytical Manual (BAM) or U.S. Department of Agriculture (USDA)/Food Safety and Inspection Service (FSIS) Microbiology Laboratory Guidebook. After 48 h of incubation, the PCR method in all cases showed equal or better results than the reference cultural FDA/BAM or USDA/FSIS methods. Fifteen out of 20 tested food types gave exactly the same amount of positive samples for both methods in both inoculation levels. For 5 out of 20 foodstuffs, the PCR method resulted in more positives than the reference method after 48 h of incubation. Following AOAC RI definition, these were false positives because they were not confirmed by the reference method (false-positive rate for low inoculated foodstuffs: 5.4%; for high inoculated foodstuffs: 7.1%). Without calculating these unconfirmed positives, the PCR method showed equal sensitivity results compared to the alternative method. With the unconfirmed PCR-positives included into the calculations, the alternative PCR method showed a higher sensitivity than the microbiological methods (low inoculation level: 100 vs 98.0%; sensitivity rate: 1; high inoculation level: 99.7 vs 97.7%; sensitivity rate, 1). All in-house and independently tested uninoculated food samples were negative for L. monocytogenes. The ruggedness testing of both ShortPrep foodproof II Kit and Roche/BIOTECON LightCycler foodproof L. monocytogenes Detection Kit showed no noteworthy influences to any variation of the parameters component concentration, apparatus comparison, tester comparison, and sample volumes. In total, 102 L. monocytogenes isolates (cultures and pure DNA) were tested and detected for the inclusivity study, including all isolates claimed by the AOAC RI. The exclusivity study included 60 non-L. monocytogenes bacteria. None of the tested isolates gave a false-positive result; specificity was 100%. Three different lots were tested in the lot-to-lot study. All 3 lots gave equal results. The stability study was subdivided into 3 parts: long-term study, stress test, and freeze-defrost test. Three lots were tested in 4 time intervals within a period of 13 months. They all gave comparable results for all test intervals. For the stress test, LightCycler L. monocytogenes detection mixes were stored at different temperatures and tested at different time points during 1 month. Stable results were produced at all storage temperatures. The freeze-defrost analysis showed no noteworthy aggravation of test results. The independent validation study examined by Campden and Chorleywood Food Research Association Group (CCFRA) demonstrated again that the LightCycler L. monocytogenes detection system shows a comparable sensitivity to reference methods. With both the LightCycler PCR and BAM methods, 19 out of 20 inoculated food samples were detected. The 24 h PCR results generated by the LightCycler system corresponded directly with the FDA/BAM culture results. However, the 48 h PCR results did not relate exactly to the FDA/BAM results, as one sample found to be positive by the 48 h PCR could not be culturally confirmed and another sample which was negative by the 48 h PCR was culturally positive.

  5. PubMed Central

    Derouin, F.; Garin, Y. J.; Buffard, C.; Berthelot, F.; Petithory, J. C.

    1994-01-01

    A collaborative study conducted by the French National Agency for Quality Control in Parasitology (CNQP) and various manufacturers of ELISA kits, represented by the Association of Laboratory Reagent Manufacturers (SFRL) compared the toxoplasmosis IgG antibody titres obtained with different ELISA-IgG kits and determined the relationships between the titres obtained by these techniques and the titre defined in international units (IU). Fifty-one serum samples with toxoplasmosis antibody titres ranging from 0 to 900 IU were tested in two successive studies with 16 ELISA-IgG kits. For the negative sera, false-positive reactions were observed with one kit. For the positive sera, the titres observed in ELISA were generally higher than those expressed in IU. Above 250 IU, the very wide variability of the titres found with the different ELISA kits renders any comparative analysis impossible. For titres below 250 IU, the results are sufficiently homogeneous to permit the use of regression analysis to study how the results for each ELISA kit compare with the mean results for the other kits. The slope of the line of regression shows a tendency to over-titration or under-titration compared with the results of the other manufacturers; the ordinate at the origin reflects the positivity threshold of the reaction and can be used to assess the risk of a lack of sensitivity (high threshold) or of specificity (threshold too low). On the whole, the trends revealed for a given manufacturer are constant from one study to the other. Within this range of titres, regression analysis also reveals the general tendency of ELISA kits to overestimate the titres by comparison with immunofluorescence.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8205645

  6. Identification and measurement of beta-lactam antibiotic residues in milk: integration of screening kits with liquid chromatography.

    PubMed

    Harik-Khan, R; Moats, W A

    1995-01-01

    A procedure for identifying and quantitating violative beta-lactams in milk is described. This procedure integrates beta-lactam residue detection kits with the multiresidue automated liquid chromatographic (LC) cleanup method developed in our laboratory. Spiked milk was deproteinized, extracted, and subjected to reversed-phase LC using a gradient program that concentrated the beta-lactams. Amoxicillin, ampicillin, cephapirin, ceftiofur, cloxacillin, and penicillin G were, thus, separated into 5 fractions that were subsequently tested for activity by using 4 kits. beta-lactams in the positive fractions were quantitated by analytical LC methods developed in our laboratory. The LC cleanup method separated beta-lactam antibiotics from each other and from interferences in the matrix and also concentrated the antibiotics, thus increasing the sensitivity of the kits to the beta-lactam antibiotics. The procedure facilitated the task of identifying and measuring the beta-lactam antibiotics that may be present in milk samples.

  7. A silent allele in the locus D5S818 contained within the PowerPlex®21 PCR Amplification Kit.

    PubMed

    Chen, Ling; Tai, Yunchun; Qiu, Pingming; Du, Weian; Liu, Chao

    2015-11-01

    Three paternity tests cases were found with a single locus mismatch at the locus D5S818 with PowerPlex®21 PCR Amplification Kit (Promega). Forward and reverse primers were redesigned to type the samples again and to evaluate if there were alleles dropped out. The results showed the existence of a silent allele 12 in all the three families, due to a point mutation that changed cytosine to adenine at 90 nucleotides upstream from the 5' end of the AGAT repeat sequences in all the six individuals. A single locus mismatch due to a silent allele may occur in any locus using any kit. Therefore, we recommend using multiple kits to confirm the results in paternity testing cases with mismatches, especially when there is a single locus mismatch with homozygote involved. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. Reaching women who do not participate in the regular cervical cancer screening programme by offering self-sampling kits: a systematic review and meta-analysis of randomised trials.

    PubMed

    Verdoodt, F; Jentschke, M; Hillemanns, P; Racey, C S; Snijders, P J F; Arbyn, M

    2015-11-01

    Population coverage for cervical cancer screening is an important determinant explaining differences in the incidence of cervical cancer between countries. Offering devices for self-sampling has the potential to increase participation of hard-to-reach women. A systematic review and meta-analysis were performed to evaluate the participation after an invitation including a self-sampling device (self-sampling arm) versus an invitation to have a sample taken by a health professional (control arm), sent to under-screened women. Sixteen randomised studies were found eligible. In an intention-to-treat analysis, the pooled participation in the self-sampling arm was 23.6% (95% confidence interval (CI)=20.2-27.3%), when self-sampling kits were sent by mail to all women, versus 10.3% (95% CI=6.2-15.2%) in the control arm (participation difference: 12.6% [95% CI=9.3-15.9]). When women had to opt-in to receive the self-sampling device, as used in three studies, the pooled participation was not higher in the self-sampling compared to the control arm (participation difference: 0.2% [95% CI=-4.5-4.9%]). An increased participation was observed in the self-sampling arm compared to the control arm, if self-sampling kits were sent directly to women at their home address. However, the size of the effect varied substantially among studies. Since participation was similar in both arms when women had to opt-in, future studies are warranted to discern opt-in scenarios that are most acceptable to women. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Preliminary characterization of digestive enzymes in freshwater mussels

    USGS Publications Warehouse

    Sauey, Blake W.; Amberg, Jon J.; Cooper, Scott T.; Grunwald, Sandra K.; Newton, Teresa J.; Haro, Roger J.

    2015-01-01

    Resource managers lack an effective chemical tool to control the invasive zebra mussel Dreissena polymorpha. Zebra mussels clog water intakes for hydroelectric companies, harm unionid mussel species, and are believed to be a reservoir of avian botulism. Little is known about the digestive physiology of zebra mussels and unionid mussels. The enzymatic profile of the digestive glands of zebra mussels and native threeridge (Amblema plicata) and plain pocketbook mussels (Lampsilis cardium) are characterized using a commercial enzyme kit, api ZYM, and validated the kit with reagent-grade enzymes. A linear correlation was shown for only one of nineteen enzymes, tested between the api ZYM kit and a specific enzyme kit. Thus, the api ZYM kit should only be used to make general comparisons of enzyme presence and to observe trends in enzyme activities. Enzymatic trends were seen in the unionid mussel species, but not in zebra mussels sampled 32 days apart from the same location. Enzymatic classes, based on substrate, showed different trends, with proteolytic and phospholytic enzymes having the most change in relative enzyme activity.

  10. Analysis of direct-to-consumer marketed Chlamydia trachomatis diagnostic tests in Norway.

    PubMed

    Reinton, Nils; Hjelmevoll, Stig Ove; Håheim, Håkon; Garstad, Kjersti; Mørch-Reiersen, Lisa Therese; Moghaddam, Amir

    2015-08-01

    Background In 2014, and for the first time in Norway, a pharmacy chain started selling home sampling kits for Chlamydia trachomatis (C. trachomatis) detection. Direct-to-consumer diagnostic kits for C. trachomatis have been available in Norway from an Internet company since 2005. There has been little assessment of persons who purchase direct-to-consumer diagnostic tests for sexually transmissible infections (STIs) detection and if low-risk populations are being unnecessarily encouraged to buy these tests. The prevalence of C. trachomatis in customers who purchased home sampling kits from the pharmacy chain and from the commercial Internet Co. were compared to that of patients attending STI clinics and other free primary healthcare services. Prevalences of other STIs in pharmacy and Internet customers were also determined. The prevalence of C. trachomatis among pharmacy customers was 11%, almost identical to the prevalence among Internet customers (12%). In comparison, the prevalence among patients attending STI clinics in Oslo was 7.2%, which is similar to the prevalence among patients who have been tested through primary healthcare services. The prevalence of Mycoplasma genitalium was two-fold less than that of C. trachomatis in the STI and primary physician population, and significantly less in the Internet and the pharmacy population. Neisseria gonorrhoeae was not detected in urine samples from pharmacy customers or from Internet customers. Both pharmacy and Internet C. trachomatis home-sampling kits seem to be purchased by the right risk population. Marketing of direct-to-consumer N. gonorrhoeae tests and possibly M. genitalium tests cannot be justified in Norway. Direct-to-consumer diagnostic tests should be actively utilised as part of national programs in preventing the spread of C. trachomatis.

  11. Methods and kits for predicting a response to an erythropoietic agent

    DOEpatents

    Merchant, Michael L.; Klein, Jon B.; Brier, Michael E.; Gaweda, Adam E.

    2015-06-16

    Methods for predicting a response to an erythropoietic agent in a subject include providing a biological sample from the subject, and determining an amount in the sample of at least one peptide selected from the group consisting of SEQ ID NOS: 1-17. If there is a measurable difference in the amount of the at least one peptide in the sample, when compared to a control level of the same peptide, the subject is then predicted to have a good response or a poor response to the erythropoietic agent. Kits for predicting a response to an erythropoietic agent are further provided and include one or more antibodies, or fragments thereof, that specifically recognize a peptide of SEQ ID NOS: 1-17.

  12. Modification of the BAX Salmonella test kit to include a hot start functionality (modification of AOAC Official Method 2003.09).

    PubMed

    Wallace, F Morgan; DiCosimo, Deana; Farnum, Andrew; Tice, George; Andaloro, Bridget; Davis, Eugene; Burns, Frank R

    2011-01-01

    In 2010, the BAX System PCR assay for Salmonella was modified to include a hot start functionality designed to keep the reaction enzyme inactive until PCR begins. To validate the assay's Official Methods of Analysis status to include this procedure modification, an evaluation was conducted on four food types that were simultaneously analyzed with the BAX System and either the U.S. Food and Drug Administration's Bacteriological Analytical Manual or the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook reference method for detecting Salmonella. Identical performance between the BAX System method and the reference methods was observed. Additionally, lysates were analyzed using both the BAX System Classic and BAX System Q7 instruments with identical results using both platforms for all samples tested. Of the 100 samples analyzed, 34 samples were positive for both the BAX System and reference methods, and 66 samples were negative by both the BAX System and reference methods, demonstrating 100% correlation. No instrument platform variation was observed. Additional inclusivity and exclusivity testing using the modified test kit demonstrated the test kit to be 100% accurate in evaluation of test panels of 352 Salmonella strains and 46 non-Salmonella strains.

  13. The Use of Laser Microdissection in Forensic Sexual Assault Casework: Pros and Cons Compared to Standard Methods.

    PubMed

    Costa, Sergio; Correia-de-Sá, Paulo; Porto, Maria J; Cainé, Laura

    2017-07-01

    Sexual assault samples are among the most frequently analyzed in a forensic laboratory. These account for almost half of all samples processed routinely, and a large portion of these cases remain unsolved. These samples often pose problems to traditional analytic methods of identification because they consist most frequently of cell mixtures from at least two contributors: the victim (usually female) and the perpetrator (usually male). In this study, we propose the use of current preliminary testing for sperm detection in order to determine the chances of success when faced with samples which can be good candidates to undergo analysis with the laser microdissection technology. Also, we used laser microdissection technology to capture fluorescently stained cells of interest differentiated by gender. Collected materials were then used for DNA genotyping with commercially available amplification kits such as Minifiler, Identifiler Plus, NGM, and Y-Filer. Both the methodology and the quality of the results were evaluated to assess the pros and cons of laser microdissection compared with standard methods. Overall, the combination of fluorescent staining combined with the Minifiler amplification kit provided the best results for autosomal markers, whereas the Y-Filer kit returned the expected results regardless of the used method. © 2017 American Academy of Forensic Sciences.

  14. TECHNOLOGIES FORM MONITORING AND ...

    EPA Pesticide Factsheets

    A demonstration of technologies for determining the presence of dioxin and dioxin-like compounds in soil and sediment was conducted under EPA's Superfund Innovative Technology Evaluation Program in Saginaw, Michigan in April 2004. This report describes the evaluation of Wako Pure Chemical Industries's Dioxin ELISA Kit. The kit is an immunoassay technique that reports toxicity equivalents (TEQ) of dioxin/furans. The sample units are in pg/g 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) equivalents (EQ). The technology results were compared to high resolution mass spectrometry (HRMS) TEQ results generated using EPA Method 1613B.The Wako results were biased both positively and negatively relative to HRMS results. The technologys estimated method detection limit was 83-201 pg/g 2,3,7,8-TCDD EQ, but this should be considered a rough estimate. Results from this demonstration suggest that the Wako kit could be an effective screening tool for determining sample results above and below 20 pg/g TEQ, and even more effective as a screen for samples above and below 50 pg/g TEQ, particularly considering the cost to analyze the 209 demonstration samples was significantly less than that of the reference laboratory ($150,294 vs. $213,580), and all samples were analyzed on-site in 9 days (in comparison to the reference laboratory which took 8 months). The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented per

  15. Effective removal of co-purified inhibitors from extracted DNA samples using synchronous coefficient of drag alteration (SCODA) technology.

    PubMed

    Schmedes, Sarah; Marshall, Pamela; King, Jonathan L; Budowle, Bruce

    2013-07-01

    Various types of biological samples present challenges for extraction of DNA suitable for subsequent molecular analyses. Commonly used extraction methods, such as silica membrane columns and phenol-chloroform, while highly successful may still fail to provide a sufficiently pure DNA extract with some samples. Synchronous coefficient of drag alteration (SCODA), implemented in Boreal Genomics' Aurora Nucleic Acid Extraction System (Boreal Genomics, Vancouver, BC), is a new technology that offers the potential to remove inhibitors effectively while simultaneously concentrating DNA. In this initial study, SCODA was tested for its ability to remove various concentrations of forensically and medically relevant polymerase chain reaction (PCR) inhibitors naturally found in tissue, hair, blood, plant, and soil samples. SCODA was used to purify and concentrate DNA from intentionally contaminated DNA samples containing known concentrations of hematin, humic acid, melanin, and tannic acid. The internal positive control (IPC) provided in the Quantifiler™ Human DNA Quantification Kit (Life Technologies, Foster City, CA) and short tandem repeat (STR) profiling (AmpFℓSTR® Identifiler® Plus PCR Amplification Kit; Life Technologies, Foster City, CA) were used to measure inhibition effects and hence purification. SCODA methodology yielded overall higher efficiency of purification of highly contaminated samples compared with the QIAquick® PCR Purification Kit (Qiagen, Valencia, CA). SCODA-purified DNA yielded no cycle shift of the IPC for each sample and yielded greater allele percentage recovery and relative fluorescence unit values compared with the QIAquick® purification method. The Aurora provided an automated, minimal-step approach to successfully remove inhibitors and concentrate DNA from challenged samples.

  16. Thirsk with SSK in JPM

    NASA Image and Video Library

    2009-07-15

    ISS020-E-020652 (15 July 2009) --- Canadian Space Agency astronaut Robert Thirsk, Expedition 20 flight engineer, uses the Surface Sample Kit (SSK) to collect microbiology samples from specific sampling locations in the Harmony node and other modules of the International Space Station.

  17. Use of DNA sequencing to detect pathogenic, saprotrophic, and stain fungi in sapwood of declining red pine (Pinus resinosa) in the Upper Midwest

    Treesearch

    M.T. Banik; D.L. Lindner; J. Juzwik; J.A. Glaeser

    2013-01-01

    An inexpensive kit was developed to collect wood samples for molecular detection of pathogenic, saprotrophic and stain fungi in declining Pinus resinosa in the Upper Midwest. The kit contained materials for "clean" collection of sapwood drill shavings, which were then subjected to PCR of the rDNA ITS region with fungal-specific primers,...

  18. Oncogenic mutations in melanomas and benign melanocytic nevi of the female genital tract

    PubMed Central

    Tseng, Diane; Kim, Julie; Warrick, Andrea; Nelson, Dylan; Pukay, Marina; Beadling, Carol; Heinrich, Michael; Selim, Maria Angelica; Corless, Christopher L.; Nelson, Kelly

    2015-01-01

    Background The genetic heterogeneity of melanomas and melanocytic nevi of the female genital tract is poorly understood. Objective We aim to characterize the frequency of mutations of the following genes: BRAF, NRAS, KIT, GNA11, and GNAQ in female genital tract melanomas. We also characterize the frequency of BRAF mutations in female genital tract melanomas compared with melanocytic nevi. Methods Mutational screening was performed on the following female genital tract melanocytic neoplasms: 25 melanomas, 7 benign melanocytic nevi, and 4 atypical melanocytic nevi. Results Of the 25 female genital tract melanoma specimens queried, KIT mutations were detected in 4 (16.0%), NRAS mutations in 4 (16.0%), and BRAF mutations in 2 (8.0%) samples. Two of the tumors with KIT mutations harbored double mutations in the same exon. No GNAQ or GNA11 mutations were identified among 11 melanomas screened. BRAF V600E mutations were detected in 7 of 7 benign melanocytic genital nevi (100%) and 3 of 4 atypical genital nevi (75%). Limitations Our study is limited by the small sample size of this rare subset of melanomas. Conclusion KIT, NRAS, and BRAF mutations are found in a subset of female genital tract melanomas. Screening for oncogenic mutations is important for developing and applying clinical therapies for melanomas of the female genital tract. PMID:24842760

  19. Fast and simple DNA extraction from saliva and sperm cells obtained from the skin or isolated from swabs.

    PubMed

    von Wurmb-Schwark, Nicole; Mályusz, Victoria; Fremdt, Heike; Koch, Christine; Simeoni, Eva; Schwark, Thorsten

    2006-05-01

    The forensic scientist often has to cope with problematic samples from the crime scene due to their minute size and thus the low amount of extractable DNA. The retrieval of DNA from swabs taken from the surface of the skin, for example, in cases of strangulation, can be especially difficult. We systematically investigated swabs taken from the skin (to obtain a genetic profile from the victim and also from a possible offender) and from sperm cell containing swabs using two extraction kits: the Invisorb forensic and the Invisorb spin swab kit (both Invitek, Germany). DNA quality and quantity were tested on ethidium bromide containing agarose gels and in a highly sensitive duplex-PCR, which amplifies fragments specific for mitochondrial and nuclear DNA. Absolute quantification was done using real time PCR. Samples, which were positive in the duplex-PCR, were also employed to genetic fingerprinting using the Powerplex ES and the AmpFlSTRIdentifiler(TM) kits. Our study shows that the easy-to-use Invisorb spin swab kit is very suitable for DNA isolation from swabs taken from the skin and also from sperm cells. Retrieval of cells from the skin with swabs moistened in extraction buffer, not in distilled water, led to a significant higher DNA yield.

  20. Long-lived immunity to canine core vaccine antigens in UK dogs as assessed by an in-practice test kit.

    PubMed

    Killey, R; Mynors, C; Pearce, R; Nell, A; Prentis, A; Day, M J

    2018-01-01

    To determine the utility of an in-practice test kit to detect protective serum antibody against canine distemper virus, canine adenovirus and canine parvovirus type 2 in a sample of the UK dog population. Serum samples from 486 dogs, last vaccinated between less than 1 month and 124 months previously, were tested with the VacciCheck™ test kit for protective antibodies against distemper, adenovirus and parvovirus type 2. A high proportion of the dogs tested (93·6%) had protective antibody against all three of the core vaccine antigens: 95·7% of the dogs were seropositive against canine distemper virus, 97·3% against canine adenovirus and 98·5% against canine parvovirus type 2. The small number of dogs that were seronegative for one or more of the antigens (n = 31) may have had waning of previous serum antibody or may have been rare genetic non-responders to that specific antigen. UK veterinarians can be reassured that triennial revaccination of adult dogs with core vaccines provides long-lived protective immunity. In-practice serological test kits are a valuable tool for informing decision-making about canine core revaccination. © 2017 British Small Animal Veterinary Association.

  1. Validation of ALK/ROS1 Dual Break Apart FISH Probe probe in non-small-cell lung cancer.

    PubMed

    Lim, Sun Min; Chang, Hyun; Cha, Yoon Jin; Liang, Shile; Tai, Yan Chin; Li, Gu; Pestova, Ekaterina; Policht, Frank; Perez, Thomas; Soo, Ross A; Park, Won Young; Kim, Hye Ryun; Shim, Hyo Sup; Cho, Byoung Chul

    2017-09-01

    ALK and ROS1 gene rearrangements are distinct molecular subsets of non-small-cell lung cancer (NSCLC), and they are strong predictive biomarkers of response to ALK/ROS1 inhibitors, such as crizotinib. Thus, it is clinically important to develop an effective screening strategy to detect patients who will benefit from such treatment. In this study, we aimed to validate analytical performance of Vysis ALK/ROS1 Dual Break Apart Probe Kit (RUO) in NSCLC. Study population composed of three patient cohorts with histologically confirmed lung adenocarcinoma (patients with ALK rearrangement, patients with ROS1 rearrangement and patients with wild-type ALK and ROS1). Specimens consisted of 12 ALK-positive, 8 ROS1-positive and 21 ALK/ROS1-wild type formalin-fixed paraffin-embedded samples obtained from surgical resection or excisional biopsy. ALK rearrangement was previously assessed by Vysis ALK Break Apart FISH Probe Kit (Abbott Molecular, Abbot Park, IL, USA) and ROS1 rearrangement was previously assessed by ZytoLight ® SPEC ROS1 Break Apart Probe (ZytoVision, GmbH). All specimens were re-evaluated by Vysis ALK/ROS1 Dual Break Apart Probe Kit. FISH images were scanned on BioView AllegroPlus system and interpreted via BioView SoloWeb remotely. For a total of 41 patient samples, the concordance of the results by Vysis ALK/ROS1 Dual Break Apart Probe Kit was evaluated and compared to the known ALK and ROS1 rearrangement status of the specimen. Of the 12 ALK-positive cases, hybridization with Vysis ALK/ROS1 Dual Break Apart Probe Kit was successful in 10 cases (success rate 10/12, 83%) and of these 10 cases, all showed ALK rearrangement (100% concordance with the results of Vysis ALK Break Apart FISH Probe Kit). Two of the ALK+ cases were excluded due to weak ROS1 signals that could not be enumerated. Of the 8 ROS1-positive cases, 6 cases were successfully evaluated using Vysis ALK/ROS1 Dual Break Apart Probe Kit. The success rate was 75% (6/8), and of these 6 cases, all showed ROS1 rearrangement, giving a 100% concordance with ZytoLight ® SPEC ROS1 Break Apart Probe. Two of the cases were excluded due to weak ROS1 gold signal or high background. In the cohort of 21 wild-type cases, the success rate using Vysis ALK/ROS1 Dual Break Apart FISH Probe Kit was 85% (18/21) and the concordance with ALK and ROS1 probe kit was 100% (18/18). Vysis ALK/ROS1 Dual Break Apart Probe Kit (RUO) can detect ALK and ROS1 rearrangement simultaneously in NSCLC. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Paternity testing in case of brother-sister incest.

    PubMed

    Macan, Marijana; Uvodić, Petra; Botica, Vladimir

    2003-06-01

    We performed a paternity test in a case of incest between brother and sister. DNA from blood samples of the alleged parents and their two children was obtained with Chelex DNA extraction method and quantified with Applied Biosystems QuantiBlot quantitation kit. Polymerase chain reaction (PCR) amplification of DNA samples was performed with AmpFlSTR SGM Plus PCR amplification kit and GenePrint PowerPlex PCR amplification kit. The amplified products were separated and detected by using the Perkin Elmer's ABI PRISM trade mark 310 Genetic Analyser. DNA and data analysis of 17 loci and Amelogenin confirmed the suspicion of brother-sister incest. Since both children had inherited all of the obligate alleles from the alleged father, we could confirm with certainty of 99.999999% that the oldest brother in the family was the biological father of both children. Calculated data showed that even in a case of brother-sister incest, paternity could be proved by the analysis of Amelogenin and 17 DNA loci.

  3. High levels of macrolide-resistant Mycoplasma genitalium in Queensland, Australia.

    PubMed

    Trembizki, Ella; Buckley, Cameron; Bletchly, Cheryl; Nimmo, Graeme R; Whiley, David M

    2017-10-01

    The macrolide azithromycin is recommended for treatment of Mycoplasma genitalium infection; however, M. genitalium strains possessing macrolide resistance-mediating mutations (MRMMs) are increasingly being reported. Here, we used the SpeeDx ResistancePlus MG kit, which provides simultaneous detection of M. genitalium and MRMMs, to assess MRMM carriage among M. genitalium infections in Queensland, Australia. Performance characteristics of the ResistancePlus MG kit for M. genitalium detection were compared to in-house PCR. Available M. genitalium PCR-positive (n=67) and negative (n=281) samples from the years 2011 to 2017 were tested using the SpeeDx ResistancePlus MG kit. In total, 63.6 % M. genitalium-positive samples were indicated to harbour MRMMs. The ResistancePlus MG method provided sensitivity and specificity of 97 and 99.6 % respectively compared to in-house PCR for M. genitalium detection. Such high levels of macrolide-resistant M. genitalium raise further concerns over future use of azithromycin for treatment of M. genitalium infection.

  4. Assessment of DNA extracted from FTA® cards for use on the Illumina iSelect BeadChip

    PubMed Central

    McClure, Matthew C; McKay, Stephanie D; Schnabel, Robert D; Taylor, Jeremy F

    2009-01-01

    Background As FTA® cards provide an ideal medium for the field collection of DNA we sought to assess the quality of genomic DNA extracted from this source for use on the Illumina BovineSNP50 iSelect BeadChip which requires unbound, relatively intact (fragment sizes ≥ 2 kb), and high-quality DNA. Bovine blood and nasal swab samples collected on FTA cards were extracted using the commercially available GenSolve kit with a minor modification. The call rate and concordance of genotypes from each sample were compared to those obtained from whole blood samples extracted by standard PCI extraction. Findings An ANOVA analysis indicated no significant difference (P > 0.72) in BovineSNP50 genotype call rate between DNA extracted from FTA cards by the GenSolve kit or extracted from whole blood by PCI. Two sample t-tests demonstrated that the DNA extracted from the FTA cards produced genotype call and concordance rates that were not different to those produced by assaying DNA samples extracted by PCI from whole blood. Conclusion We conclude that DNA extracted from FTA cards by the GenSolve kit is of sufficiently high quality to produce results comparable to those obtained from DNA extracted from whole blood when assayed by the Illumina iSelect technology. Additionally, we validate the use of nasal swabs as an alternative to venous blood or buccal samples from animal subjects for reliably producing high quality genotypes on this platform. PMID:19531223

  5. Assessment of DNA extracted from FTA cards for use on the Illumina iSelect BeadChip.

    PubMed

    McClure, Matthew C; McKay, Stephanie D; Schnabel, Robert D; Taylor, Jeremy F

    2009-06-16

    As FTA cards provide an ideal medium for the field collection of DNA we sought to assess the quality of genomic DNA extracted from this source for use on the Illumina BovineSNP50 iSelect BeadChip which requires unbound, relatively intact (fragment sizes >or= 2 kb), and high-quality DNA. Bovine blood and nasal swab samples collected on FTA cards were extracted using the commercially available GenSolve kit with a minor modification. The call rate and concordance of genotypes from each sample were compared to those obtained from whole blood samples extracted by standard PCI extraction. An ANOVA analysis indicated no significant difference (P > 0.72) in BovineSNP50 genotype call rate between DNA extracted from FTA cards by the GenSolve kit or extracted from whole blood by PCI. Two sample t-tests demonstrated that the DNA extracted from the FTA cards produced genotype call and concordance rates that were not different to those produced by assaying DNA samples extracted by PCI from whole blood. We conclude that DNA extracted from FTA cards by the GenSolve kit is of sufficiently high quality to produce results comparable to those obtained from DNA extracted from whole blood when assayed by the Illumina iSelect technology. Additionally, we validate the use of nasal swabs as an alternative to venous blood or buccal samples from animal subjects for reliably producing high quality genotypes on this platform.

  6. Assessment of canine autologous platelet-rich plasma produced with a commercial centrifugation and platelet recovery kit.

    PubMed

    Frye, Chris W; Enders, Andrew; Brooks, Marjory B; Struble, Angela M; Wakshlag, Joseph J

    2016-01-01

    To characterize the cellular composition (platelets, erythrocytes, and leukocytes) and confirm reproducibility of platelet enrichment, as well as determine the platelet activation status in the final product of a commercial platelet-rich plasma kit using canine blood. Venous blood from 20 sedated client-owned dogs was used to prepare platelet-rich plasma (PRP) from a commercial kit. Complete blood counts were performed to determine erythrocyte, leukocyte, and platelet numbers in both whole blood (WB) and resultant PRP. The WB and PRP samples from jugular (fast collection) and cephalic (slow collection) venipuncture were also compared. P-selectin externalization was measured in WB and PRP samples from 15 of 20 dogs. This commercial kit produced an average percent recovery in platelets of 64.7 ± 17.4; erythrocytes of 3.7 ± 0.8, and leukocytes of 31.6 ± 10.0. Neutrophil, monocyte, and lymphocyte percent recovery was 19.6 ± 7.2, 44.89 ± 19.8, and 57.5 ± 10.6, respectively. The recovery of platelets from jugular venipuncture (59.7 ± 13.6%) was lower than from cephalic recovery (68.8 ± 19.1%). The mean percent P-Selectin externalization for WB, PRP, and PRP with thrombin was 25.5 ± 30.9, 4.5 ± 6.4, and 90.6 ± 4.4 respectively. Cellular reproducibility of this kit was confirmed and platelets were concentrated within autologous serum. Additionally, measurements of P-selectin externalization showed that platelets are inactive in PRP unless stimulated to degranulate.

  7. Investigator® HDplex (Qiagen) reference population database for forensic use in Argentina.

    PubMed

    Martínez, Gustavo; Borosky, Alicia; Corach, Daniel; Llull, Cintia; Locarno, Laura; Lojo, Mercedes; Marino, Miguel; Miozzo, María Cecilia; Modesti, Nidia; Pacharoni, Carla; Pilili, Juan Pablo; Ramella, María Isabel; Sala, Andrea; Schaller, Cecilia; Vullo, Carlos; Toscanini, Ulises

    2017-01-01

    Currently, autosomal Short Tandem Repeat (STR) markers represent the method of election in forensic human identification. Commercial kits of most common use nowadays -e.g. PowerPlex ® Fusion, Promega Corp.; AmpFlSTR GlobalFiler, Thermofisher scientific; Investigator 24Plex QS,Qiagen-, allow the co-amplification of 23 highly polymorphic STR loci providing a high discrimination power in human identity testing. However, in complex kinship analysis and familial database searches involving distant relationships, additional DNA typing is often required in order to achieve well-founded conclusions. The recently developed kit Investigator ® HDplex (Qiagen) co-amplify twelve autosomal STRs markers (D7S1517, D3S1744, D12S391, D2S1360, D6S474, D4S2366, D8S1132, D5S2500, D18S51, D21S2055, D10S2325, SE33), nine of which are not present in the above mentioned kits, providing a set of efficient supplementary markers for human identification purposes. In this study we genotyped a sample of 980 individuals from urban areas of ten Argentinean provinces using the Investigator ® HDplex kit, aiming to provide forensic estimates for use in forensic casework and parentage testing in Argentina. We report reference allelic frequency databases for each of the provinces studied as well as for the combined samples. No deviation of Hardy-Weinberg equilibrium was observed. A reasonable discrimination capacity and power of exclusion was estimated which allowed predicting an acceptable forensic behavior of this kit, either to be used as the main STR panel for simple cases or as an auxiliary tool in complex cases. Additionally, population comparison tests showed that the studied samples are relatively homogeneous across the country for these STR set. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Investigating Associations Between Proliferation Indices, C-kit, and Lymph Node Stage in Canine Mast Cell Tumors.

    PubMed

    Krick, Erika Lauren; Kiupel, Matti; Durham, Amy C; Thaiwong, Tuddow; Brown, Dorothy C; Sorenmo, Karin U

    Previous studies have evaluated cellular proliferation indices, KIT expression, and c-kit mutations to predict the clinical behavior of canine mast cell tumors (MCTs). The study purpose was to retrospectively compare mitotic index, argyrophilic nucleolar organizer regions (AgNORs)/nucleus, Ki-67 index, KIT labeling pattern, and internal tandem duplication mutations in c-KIT between stage I and stage II grade II MCTs. Medical records and tumor biopsy samples from dogs with Grade II MCTs with cytological or histopathological regional lymph node evaluation were included. Signalment, tumor location and stage, and presence of a recurrent versus de novo tumor were recorded. Mitotic index, AgNORs/nucleus, Ki-67, KIT staining pattern, and internal tandem duplication mutations in exon 11 of c-KIT were evaluated. Sixty-six tumors (51 stage I; 15 stage II) were included. Only AgNORs/nucleus and recurrent tumors were significantly associated with stage (odds ratio 2.8, 95% confidence interval [CI] 1.0-8.0, P = .049; odds ratio 8.8, 95% CI 1.1-69.5; P = .039). Receiver-operator characteristic analysis showed that the sensitivity and specificity of AgNORs/cell ≥ 1.87 were 93.3% and 27.4%, respectively, (area under the curve: 0.65) for predicting stage. Recurrent tumors and higher AgNORs/nucleus are associated with stage II grade II MCTs; however, an AgNOR cutoff value that reliably predicts lymph node metastasis was not determined.

  9. Mkit: A cell migration assay based on microfluidic device and smartphone.

    PubMed

    Yang, Ke; Wu, Jiandong; Peretz-Soroka, Hagit; Zhu, Ling; Li, Zhigang; Sang, Yaoshuo; Hipolito, Jolly; Zhang, Michael; Santos, Susy; Hillier, Craig; de Faria, Ricardo Lobato; Liu, Yong; Lin, Francis

    2018-01-15

    Mobile sensing based on the integration of microfluidic device and smartphone, so-called MS 2 technology, has enabled many applications over recent years, and continues to stimulate growing interest in both research communities and industries. In particular, it has been envisioned that MS 2 technology can be developed for various cell functional assays to enable basic research and clinical applications. Toward this direction, in this paper, we describe the development of a MS 2 -based cell functional assay for testing cell migration (the M kit ). The system is constructed as an integrated test kit, which includes microfluidic chips, a smartphone-based imaging platform, the phone apps for image capturing and data analysis, and a set of reagent and accessories for performing the cell migration assay. We demonstrated that the M kit can effectively measure purified neutrophil and cancer cell chemotaxis. Furthermore, neutrophil chemotaxis can be tested from a drop of whole blood using the M kit with red blood cell (RBC) lysis. The effects of chemoattractant dose and gradient profile on neutrophil chemotaxis were also tested using the M kit . In addition to research applications, we demonstrated the effective use of the M kit for on-site test at the hospital and for testing clinical samples from chronic obstructive pulmonary disease patient. Thus, this developed M kit provides an easy and integrated experimental platform for cell migration related research and potential medical diagnostic applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Active and realistic passive marijuana exposure tested by three immunoassays and GC/MS in urine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mule, S.J.; Lomax, P.; Gross, S.J.

    Human urine samples obtained before and after active and passive exposure to marijuana were analyzed by immune kits (Roche, Amersham, and Syva) and gas chromatography/mass spectrometry (GC/MS). Seven of eight subjects were positive for the entire five-day test period with one immune kit. The latter correlated with GC/MS in 98% of the samples. Passive inhalation experiments under conditions likely to reflect realistic exposure resulted consistently in less than 10 ng/mL of cannabinoids. The 10-100-ng/mL cannabinoid concentration range essential for detection of occasional and moderate marijuana users is thus unaffected by realistic passive inhalation.

  11. In-Flight Water Quality Monitoring on the International Space Station (ISS): Measuring Biocide Concentrations with Colorimetric Solid Phase Extraction (CSPE)

    NASA Technical Reports Server (NTRS)

    Gazda, Daniel B.; Schultz, John R.; Siperko, Lorraine M.; Porter, Marc D.; Lipert, Robert J.; Flint, Stephanie M.; McCoy, J. Torin

    2011-01-01

    The colorimetric water quality monitoring kit (CWQMK) was delivered to the International Space Station (ISS) on STS-128/17A and was initially deployed in September 2009. The kit was flown as a station development test objective (SDTO) experiment to evaluate the acceptability of colorimetric solid phase extraction (CSPE) technology for routine water quality monitoring on the ISS. During the SDTO experiment, water samples from the U.S. water processor assembly (WPA), the U.S. potable water dispenser (PWD), and the Russian system for dispensing ground-supplied water (SVO-ZV) were collected and analyzed with the CWQMK. Samples from the U.S. segment of the ISS were analyzed for molecular iodine, which is the biocide added to water in the WPA. Samples from the SVOZV system were analyzed for ionic silver, the biocide used on the Russian segment of the ISS. In all, thirteen in-flight analysis sessions were completed as part of the SDTO experiment. This paper provides an overview of the experiment and reports the results obtained with the CWQMK. The forward plan for certifying the CWQMK as operational hardware and expanding the capabilities of the kit are also discussed.

  12. Detection of human papillomavirus DNA in patients referred to a family practice colposcopy clinic.

    PubMed

    Holman, J R

    1996-01-01

    Human papillomavirus (HPV) is strongly implicated in the pathogenesis of cervical neoplasia. The ability of a commercially available kit (Virapap/Viratype) to detect evidence of HPV is compared with cervical cytology, colposcopy, and directed biopsies. During a period of 16 months, cervical samples from 241 consecutive new patients referred for a colposcopy examination were obtained for HPV-DNA hybridization typing according to the kit instructions. Samples were sent to a reference laboratory for testing. The results were compared with results of the colposcopy examination, cervical cytology, and directed cervical biopsy samples processed and evaluated by our hospital laboratory. HPV DNA was detected in 27 of 107 patients who had abnormal colposcopy findings for a sensitivity of 25 +/- 7.5 percent at the 90 percent confidence interval. One of 134 patients with normal findings was positive for a specificity of 99 +/- 5 percent at the 95 percent confidence interval. Based on a 75 percent probability of HPV in the population, the positive predictive value was 99 percent and the negative predictive value 30 percent. With the low negative predictive value and sensitivity, HPV-DNA testing by this commercial kit is not an adequate tool for screening HPV in this population.

  13. Distribution and predominance of genotype 3 in hepatitis C virus carriers in the province of kahramanmaras, Turkey.

    PubMed

    Caliskan, Ahmet; Kirisci, Ozlem; Ozkaya, Esra; Ozden, Sevinc; Tumer, Seray; Caglar, Serkan; Guler, Selma Ates; Senol, Hande

    2015-04-01

    The hepatitis C virus (HCV) has six major genotypes and more than 100 subtypes, and the determination of the responsible genotype, collection of epidemiological data, tailoring antiviral therapy, and prediction of prognosis have an important place in disease management. The aim of the present study was to determine the distribution of HCV genotypes across geographic regions and compare these data with those obtained from other geographic locations. The HCV genotypes were identified in HCV RNA positive blood samples, obtained from different centers. The HCV genotype was determined using molecular methods [Real-Time Polymerase Chain Reaction (RT-PCR)] in 313 patients, who were found to be positive for HCV RNA. The presence of HCV RNA was investigated using the RT-PCR method in serum samples delivered to the Microbiology Laboratory at Kahramanmaras Necip Fazıl City Hospital, Kahramanmaras, Turkey, from the centers located in Kahramanmaras City center and peripheral districts of the province, between March 2010 and August 2014. The HCV genotype analysis was performed in HCV RNA positive samples, using RT-PCR reagents kit. Urine samples from the patients were tested for amphetamine with an Amphetamines II (AMPS2) kit, cocaine was tested with a Cocaine II (COC2) kit, opiates were tested with an Opiates II (OPI2) kit, and cannabinoids were tested with a Cannabinoids II (THC2) kit in Roche/Hitachi Cobas c501 device. The blood samples collected from 313 patients were included in the study. Of these patients, 212 (67.7%) were male and 101 (32.3%) were female. The mean age of the patients was 41.29 ± 20.32 years. In terms of HCV genotype distribution, 162 patients (51.7%) had genotype 1, 144 patients (46%) had genotype 3, four patients (1.3%) had genotype 2, and three patients (1%) had genotype 4. The results of urine drug tests were available in only 65 patients (20.2%). Of these, 61 (93.8%) patients had HCV genotype 3. In conclusion, the prevalence of HCV genotype 1 was 51.7%, which was lower than the rates reported in other studies in Turkey, while the prevalence of HCV genotype 3 was 46%, which was remarkably higher than the reported Turkish data. In addition, the prevalence rate for genotype 3 reported in the present study is the highest that has ever been reported in the literature.

  14. Prediction of autosomal STR typing success in ancient and Second World War bone samples.

    PubMed

    Zupanič Pajnič, Irena; Zupanc, Tomaž; Balažic, Jože; Geršak, Živa Miriam; Stojković, Oliver; Skadrić, Ivan; Črešnar, Matija

    2017-03-01

    Human-specific quantitative PCR (qPCR) has been developed for forensic use in the last 10 years and is the preferred DNA quantification technique since it is very accurate, sensitive, objective, time-effective and automatable. The amount of information that can be gleaned from a single quantification reaction using commercially available quantification kits has increased from the quantity of nuclear DNA to the amount of male DNA, presence of inhibitors and, most recently, to the degree of DNA degradation. In skeletal remains samples from disaster victims, missing persons and war conflict victims, the DNA is usually degraded. Therefore the new commercial qPCR kits able to assess the degree of degradation are potentially able to predict the success of downstream short tandem repeat (STR) typing. The goal of this study was to verify the quantification step using the PowerQuant kit with regard to its suitability as a screening method for autosomal STR typing success on ancient and Second World War (WWII) skeletal remains. We analysed 60 skeletons excavated from five archaeological sites and four WWII mass graves from Slovenia. The bones were cleaned, surface contamination was removed and the bones ground to a powder. Genomic DNA was obtained from 0.5g of bone powder after total demineralization. The DNA was purified using a Biorobot EZ1 device. Following PowerQuant quantification, DNA samples were subjected to autosomal STR amplification using the NGM kit. Up to 2.51ng DNA/g of powder were extracted. No inhibition was detected in any of bones analysed. 82% of the WWII bones gave full profiles while 73% of the ancient bones gave profiles not suitable for interpretation. Four bone extracts yielded no detectable amplification or zero quantification results and no profiles were obtained from any of them. Full or useful partial profiles were produced only from bone extracts where short autosomal (Auto) and long degradation (Deg) PowerQuant targets were detected. It is concluded that STR typing of old bones after quantification with the PowerQuant should be performed only when both Auto and Deg targets are detected simultaneously with no respect to [Auto]/[Deg] ratio. Prediction of STR typing success could be made according to successful amplification of Deg fragment. The PowerQuant kit is capable of identifying bone DNA samples that will not yield useful STR profiles using the NGM kit, and it can be used as a predictor of autosomal STR typing success of bone extracts obtained from ancient and WWII skeletal remains. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Evaluating Protocols for Porcine Faecal Microbiome Recollection, Storage and DNA Extraction: from the Farm to the Lab.

    PubMed

    Muiños-Bühl, Anixa; González-Recio, Oscar; Muñoz, María; Óvilo, Cristina; García-Casco, Juan; Fernández, Ana I

    2018-06-01

    There is a growing interest in understanding the role of the gut microbiome on productive and meat quality-related traits in livestock species in order to develop new useful tools for improving pig production systems and industry. Faecal samples are analysed as a proxy of gut microbiota and here the selection of suitable protocols for faecal sampling and DNA isolation is a critical first step in order to obtain reliable results, even more to compare results obtained from different studies. The aim of the current study was to establish in a cost-effective way, using automated ribosomal intergenic spacer analysis technique, a protocol for porcine faecal sampling and storage at farm and slaughterhouse and to determine the most efficient microbiota DNA isolation kit among those most widely used. Operational Taxonomic Unit profiles were compared from Iberian pig faecal samples collected from rectum or ground, stored with liquid N 2 , room temperature or RNAlater, and processed with QIAamp DNA Stool (Qiagen), PowerFecal DNA Isolation (Mobio) or SpeedTools Tissue DNA extraction (Biotools) commercial kits. The results, focused on prokaryote sampling, based on DNA yield and quality, OTU number and Sørensen similarity Indexes, indicate that the recommended protocol for porcine faecal microbiome sampling at farm should include: the collection from porcine rectum to avoid contamination; the storage in liquid N 2 or even at room temperature, but not in RNAlater; and the isolation of microbiota DNA using PowerFecal DNA Isolation kit. These conditions provide more reliable DNA samples for further microbiome analysis.

  16. Field soil aggregate stability kit for soil quality and rangeland health evaluations

    USGS Publications Warehouse

    Herrick, J.E.; Whitford, W.G.; de Soyza, A. G.; Van Zee, J. W.; Havstad, K.M.; Seybold, C.A.; Walton, M.

    2001-01-01

    Soil aggregate stability is widely recognized as a key indicator of soil quality and rangeland health. However, few standard methods exist for quantifying soil stability in the field. A stability kit is described which can be inexpensively and easily assembled with minimal tools. It permits up to 18 samples to be evaluated in less than 10 min and eliminates the need for transportation, minimizing damage to soil structure. The kit consists of two 21??10.5??3.5 cm plastic boxes divided into eighteen 3.5??3.5 cm sections, eighteen 2.5-cm diameter sieves with 1.5-mm distance openings and a small spatula used for soil sampling. Soil samples are rated on a scale from one to six based on a combination of ocular observations of slaking during the first 5 min following immersion in distilled water, and the percent remaining on a 1.5-mm sieve after five dipping cycles at the end of the 5-min period. A laboratory comparison yielded a correlation between the stability class and percent aggregate stability based on oven dry weight remaining after treatment using a mechanical sieve. We have applied the method in a wide variety of agricultural and natural ecosystems throughout western North America, including northern Mexico, and have found that it is highly sensitive to differences in management and plant community composition. Although the field kit cannot replace the careful laboratory-based measurements of soil aggregate stability, it can clearly provide valuable information when these more intensive procedures are not possible.

  17. Comparative evaluation of three automated systems for DNA extraction in conjunction with three commercially available real-time PCR assays for quantitation of plasma Cytomegalovirus DNAemia in allogeneic stem cell transplant recipients.

    PubMed

    Bravo, Dayana; Clari, María Ángeles; Costa, Elisa; Muñoz-Cobo, Beatriz; Solano, Carlos; José Remigia, María; Navarro, David

    2011-08-01

    Limited data are available on the performance of different automated extraction platforms and commercially available quantitative real-time PCR (QRT-PCR) methods for the quantitation of cytomegalovirus (CMV) DNA in plasma. We compared the performance characteristics of the Abbott mSample preparation system DNA kit on the m24 SP instrument (Abbott), the High Pure viral nucleic acid kit on the COBAS AmpliPrep system (Roche), and the EZ1 Virus 2.0 kit on the BioRobot EZ1 extraction platform (Qiagen) coupled with the Abbott CMV PCR kit, the LightCycler CMV Quant kit (Roche), and the Q-CMV complete kit (Nanogen), for both plasma specimens from allogeneic stem cell transplant (Allo-SCT) recipients (n = 42) and the OptiQuant CMV DNA panel (AcroMetrix). The EZ1 system displayed the highest extraction efficiency over a wide range of CMV plasma DNA loads, followed by the m24 and the AmpliPrep methods. The Nanogen PCR assay yielded higher mean CMV plasma DNA values than the Abbott and the Roche PCR assays, regardless of the platform used for DNA extraction. Overall, the effects of the extraction method and the QRT-PCR used on CMV plasma DNA load measurements were less pronounced for specimens with high CMV DNA content (>10,000 copies/ml). The performance characteristics of the extraction methods and QRT-PCR assays evaluated herein for clinical samples were extensible at cell-based standards from AcroMetrix. In conclusion, different automated systems are not equally efficient for CMV DNA extraction from plasma specimens, and the plasma CMV DNA loads measured by commercially available QRT-PCRs can differ significantly. The above findings should be taken into consideration for the establishment of cutoff values for the initiation or cessation of preemptive antiviral therapies and for the interpretation of data from clinical studies in the Allo-SCT setting.

  18. Comparative evaluation of a laboratory developed real-time PCR assay and the RealStar® HHV-6 PCR Kit for quantitative detection of human herpesvirus 6.

    PubMed

    Yip, Cyril C Y; Sridhar, Siddharth; Cheng, Andrew K W; Fung, Ami M Y; Cheng, Vincent C C; Chan, Kwok-Hung; Yuen, Kwok-Yung

    2017-08-01

    HHV-6 reactivation in immunocompromised patients is common and may be associated with serious morbidity and mortality; therefore, early detection and initiation of therapy might be of benefit. Real-time PCR assays allow for early identification of HHV-6 reactivation to assist in providing a timely response. Thus, we compared the performance of an in-house developed HHV-6 quantitative PCR assay with a commercially available kit, the RealStar ® HHV-6 PCR Kit. The analytical sensitivity, analytical specificity, linearity, precision and accuracy of the in-house developed HHV-6 qPCR assay were evaluated. The diagnostic performance of the in-house HHV-6 qPCR assay was compared with the RealStar ® HHV-6 PCR Kit, using 72 clinical specimens and 17 proficiency testing samples. Linear regression analysis of the quantitative results showed a dynamic range from 2 to 10 log 10 copies/ml and a coefficient of determination (R 2 ) of 0.999 for the in-house assay. A dilution series demonstrated a limit of detection and a limit of quantification of 1.7 log 10 and 2 log 10 copies/ml, respectively. The precision of the assay was highly reproducible among runs with coefficients of variance (CV) ranging from 0.27% to 4.37%. A comparison of 27 matched samples showed an excellent correlation between the quantitative viral loads measured by the in-house HHV-6 qPCR assay and the RealStar ® HHV-6 PCR Kit (R 2 =0.926; P<0.0001), with an average bias of -0.24 log 10 copies/ml. The in-house developed HHV-6 qPCR method is a sensitive and reliable assay with lower cost for the detection and quantification of HHV-6 DNA when compared to the RealStar ® HHV-6 PCR Kit. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. [Individual Identification of Cartilage by Direct Amplification in Mass Disasters].

    PubMed

    Wang, C H; Xu, C; Li, X Q; Wu, Y; Du, Z

    2017-06-01

    To explore the effectiveness of direct amplification for the STR analysis of cartilage, and to accelerate the effectiveness of disaster victim identification. Eighty-eight cartilage samples were directly amplified by PowerPle® 21 kit, and the results of genotyping were compared with that obtained by the magnetic beads method. In 88 cartilage samples, the STR genotypes were successfully detected from 84 samples by direct amplification and magnetic beads method, and both the results of genotyping by two method were consistent. Direct amplification with PowerPlex® 21 kit can be used for STR genotyping of cartilages. This method is operated easily and promptly, which has a potential application in the individual identification of mass disasters. Copyright© by the Editorial Department of Journal of Forensic Medicine

  20. Bisulfite Conversion of DNA: Performance Comparison of Different Kits and Methylation Quantitation of Epigenetic Biomarkers that Have the Potential to Be Used in Non-Invasive Prenatal Testing

    PubMed Central

    Leontiou, Chrysanthia A.; Hadjidaniel, Michael D.; Mina, Petros; Antoniou, Pavlos; Ioannides, Marios; Patsalis, Philippos C.

    2015-01-01

    Introduction Epigenetic alterations, including DNA methylation, play an important role in the regulation of gene expression. Several methods exist for evaluating DNA methylation, but bisulfite sequencing remains the gold standard by which base-pair resolution of CpG methylation is achieved. The challenge of the method is that the desired outcome (conversion of unmethylated cytosines) positively correlates with the undesired side effects (DNA degradation and inappropriate conversion), thus several commercial kits try to adjust a balance between the two. The aim of this study was to compare the performance of four bisulfite conversion kits [Premium Bisulfite kit (Diagenode), EpiTect Bisulfite kit (Qiagen), MethylEdge Bisulfite Conversion System (Promega) and BisulFlash DNA Modification kit (Epigentek)] regarding conversion efficiency, DNA degradation and conversion specificity. Methods Performance was tested by combining fully methylated and fully unmethylated λ-DNA controls in a series of spikes by means of Sanger sequencing (0%, 25%, 50% and 100% methylated spikes) and Next-Generation Sequencing (0%, 3%, 5%, 7%, 10%, 25%, 50% and 100% methylated spikes). We also studied the methylation status of two of our previously published differentially methylated regions (DMRs) at base resolution by using spikes of chorionic villus sample in whole blood. Results The kits studied showed different but comparable results regarding DNA degradation, conversion efficiency and conversion specificity. However, the best performance was observed with the MethylEdge Bisulfite Conversion System (Promega) followed by the Premium Bisulfite kit (Diagenode). The DMRs, EP6 and EP10, were confirmed to be hypermethylated in the CVS and hypomethylated in whole blood. Conclusion Our findings indicate that the MethylEdge Bisulfite Conversion System (Promega) was shown to have the best performance among the kits. In addition, the methylation level of two of our DMRs, EP6 and EP10, was confirmed. Finally, we showed that bisulfite amplicon sequencing is a suitable approach for methylation analysis of targeted regions. PMID:26247357

  1. Bisulfite Conversion of DNA: Performance Comparison of Different Kits and Methylation Quantitation of Epigenetic Biomarkers that Have the Potential to Be Used in Non-Invasive Prenatal Testing.

    PubMed

    Leontiou, Chrysanthia A; Hadjidaniel, Michael D; Mina, Petros; Antoniou, Pavlos; Ioannides, Marios; Patsalis, Philippos C

    2015-01-01

    Epigenetic alterations, including DNA methylation, play an important role in the regulation of gene expression. Several methods exist for evaluating DNA methylation, but bisulfite sequencing remains the gold standard by which base-pair resolution of CpG methylation is achieved. The challenge of the method is that the desired outcome (conversion of unmethylated cytosines) positively correlates with the undesired side effects (DNA degradation and inappropriate conversion), thus several commercial kits try to adjust a balance between the two. The aim of this study was to compare the performance of four bisulfite conversion kits [Premium Bisulfite kit (Diagenode), EpiTect Bisulfite kit (Qiagen), MethylEdge Bisulfite Conversion System (Promega) and BisulFlash DNA Modification kit (Epigentek)] regarding conversion efficiency, DNA degradation and conversion specificity. Performance was tested by combining fully methylated and fully unmethylated λ-DNA controls in a series of spikes by means of Sanger sequencing (0%, 25%, 50% and 100% methylated spikes) and Next-Generation Sequencing (0%, 3%, 5%, 7%, 10%, 25%, 50% and 100% methylated spikes). We also studied the methylation status of two of our previously published differentially methylated regions (DMRs) at base resolution by using spikes of chorionic villus sample in whole blood. The kits studied showed different but comparable results regarding DNA degradation, conversion efficiency and conversion specificity. However, the best performance was observed with the MethylEdge Bisulfite Conversion System (Promega) followed by the Premium Bisulfite kit (Diagenode). The DMRs, EP6 and EP10, were confirmed to be hypermethylated in the CVS and hypomethylated in whole blood. Our findings indicate that the MethylEdge Bisulfite Conversion System (Promega) was shown to have the best performance among the kits. In addition, the methylation level of two of our DMRs, EP6 and EP10, was confirmed. Finally, we showed that bisulfite amplicon sequencing is a suitable approach for methylation analysis of targeted regions.

  2. The Moon Beams on Westlake.

    ERIC Educational Resources Information Center

    Bishop, Jeanne E.

    1979-01-01

    Presented is a community's experience with a lunar sample education kit containing actual pieces of moon rocks and soil on loan from NASA. School and community activities including mini-labs, seminars, and lunar sample viewing sessions, are described. (SA)

  3. Evaluation of Toxoplasma ELITe MGB Real-Time PCR Assay for Diagnosis of Toxoplasmosis

    PubMed Central

    Brenier-Pinchart, Marie-Pierre; Yera, Hélène; Belaz, Sorya; Varlet-Marie, Emmanuelle; Bastien, Patrick

    2017-01-01

    ABSTRACT Molecular diagnosis of congenital toxoplasmosis or disseminated toxoplasmosis is based mainly on PCR. The repeated DNA element rep529 has become the main DNA target used in most PCR methods, whether laboratory developed or commercial. In this multicenter study, we evaluated the Toxoplasma ELITe MGB (Elitech) commercial kit by comparison with three reference quantitative PCR assays (RAs) used routinely in three proficient laboratories of the French National Reference Center for Toxoplasmosis network, using Toxoplasma calibrated suspensions diluted to obtain a range of concentrations from 0.1 to 10,000 parasites/ml. These suspensions were extracted with either the DNA extraction kit (EXTRAblood; Elitech) recommended by the manufacturer or the QIAamp DNA minikit (Qiagen). The Toxoplasma ELITe MGB assay was also evaluated on a panel of 128 clinical samples, including 56 amniotic fluid samples, 55 placenta samples, and various other samples, of which 95 originated from patients with proven toxoplasmosis. The ELITe MGB assay amplified low-concentration replicates (<10 parasites/ml) of calibrated suspensions less frequently than the RAs of 2/3 laboratories. Additionally, the combination of EXTRAblood and Toxoplasma ELITe MGB yielded poorer sensitivity than the combination of QIAamp DNA minikit and ELITe MGB for low parasite concentrations (P < 0.001 for 1 parasite/ml). On clinical samples, the sensitivity and the specificity of the commercial assay were 89% and 100%, respectively. The sensitivity ranged from 79% (placenta samples) to 100% (amniotic fluid samples). Overall, this study shows that the Toxoplasma ELITe MGB assay is suitable for the diagnosis of toxoplasmosis from non-cell-rich or non-hemoglobin-rich samples and that the EXTRAblood kit is not optimal. PMID:28202794

  4. Evaluation of Toxoplasma ELITe MGB Real-Time PCR Assay for Diagnosis of Toxoplasmosis.

    PubMed

    Robert-Gangneux, Florence; Brenier-Pinchart, Marie-Pierre; Yera, Hélène; Belaz, Sorya; Varlet-Marie, Emmanuelle; Bastien, Patrick

    2017-05-01

    Molecular diagnosis of congenital toxoplasmosis or disseminated toxoplasmosis is based mainly on PCR. The repeated DNA element rep529 has become the main DNA target used in most PCR methods, whether laboratory developed or commercial. In this multicenter study, we evaluated the Toxoplasma ELITe MGB (Elitech) commercial kit by comparison with three reference quantitative PCR assays (RAs) used routinely in three proficient laboratories of the French National Reference Center for Toxoplasmosis network, using Toxoplasma calibrated suspensions diluted to obtain a range of concentrations from 0.1 to 10,000 parasites/ml. These suspensions were extracted with either the DNA extraction kit (EXTRAblood; Elitech) recommended by the manufacturer or the QIAamp DNA minikit (Qiagen). The Toxoplasma ELITe MGB assay was also evaluated on a panel of 128 clinical samples, including 56 amniotic fluid samples, 55 placenta samples, and various other samples, of which 95 originated from patients with proven toxoplasmosis. The ELITe MGB assay amplified low-concentration replicates (<10 parasites/ml) of calibrated suspensions less frequently than the RAs of 2/3 laboratories. Additionally, the combination of EXTRAblood and Toxoplasma ELITe MGB yielded poorer sensitivity than the combination of QIAamp DNA minikit and ELITe MGB for low parasite concentrations ( P < 0.001 for 1 parasite/ml). On clinical samples, the sensitivity and the specificity of the commercial assay were 89% and 100%, respectively. The sensitivity ranged from 79% (placenta samples) to 100% (amniotic fluid samples). Overall, this study shows that the Toxoplasma ELITe MGB assay is suitable for the diagnosis of toxoplasmosis from non-cell-rich or non-hemoglobin-rich samples and that the EXTRAblood kit is not optimal. Copyright © 2017 American Society for Microbiology.

  5. Unremitting Cell Proliferation in the Secretory Phase of Eutopic Endometriosis

    PubMed Central

    Franco-Murillo, Yanira; Miranda-Rodríguez, José Antonio; Rendón-Huerta, Erika; Montaño, Luis F.; Cornejo, Gerardo Velázquez; Gómez, Lucila Poblano; Valdez-Morales, Francisco Javier; Gonzalez-Sanchez, Ignacio

    2014-01-01

    Objective: Endometriosis is linked to altered cell proliferation and stem cell markers c-kit/stem cell factor (SCF) in ectopic endometrium. Our aim was to investigate whether c-kit/SCF also plays a role in eutopic endometrium. Design: Eutopic endometrium obtained from 35 women with endometriosis and 25 fertile eumenorrheic women was analyzed for in situ expression of SCF/c-kit, Ki67, RAC-alpha serine/threonine-protein kinase (Akt), phosphorylated RAC-alpha serine/threonin-protein kinase (pAkt), Glycogen synthase kinase 3 beta (GSK3β), and phosphorylated glycogen synthase kinase 3 beta (pGSK3β), throughout the menstrual cycle. Results: Expression of Ki67 and SCF was higher in endometriosis than in control tissue (P < .05) and greater in secretory rather than proliferative (P < .01) endometrium in endometriosis. Expression of c-kit was also higher in endometriosis although similar in both phases. Expression of Akt and GSK3β was identical in all samples and cycle phases, whereas pAkt and pGSK3β, opposed to control tissue, remained overexpressed in the secretory phase in endometriosis. Conclusion: Unceasing cell proliferation in the secretory phase of eutopic endometriosis is linked to deregulation of c-kit/SCF-associated signaling pathways. PMID:25194152

  6. Development of an incurred cornbread model for gluten detection by immunoassays.

    PubMed

    Sharma, Girdhari M; Khuda, Sefat E; Pereira, Marion; Slate, Andrew; Jackson, Lauren S; Pardo, Christopher; Williams, Kristina M; Whitaker, Thomas B

    2013-12-11

    Gluten that is present in food as a result of cross-contact or misbranding can cause severe health concerns to wheat-allergic and celiac patients. Immunoassays, such as enzyme-linked immunosorbent assay (ELISA) and lateral flow device (LFD), are commonly used to detect gluten traces in foods. However, the performance of immunoassays can be affected by non-assay-related factors, such as food matrix and processing conditions. Gluten (0-500 ppm) and wheat flour (20-1000 ppm) incurred cornbread was prepared at different incurred levels and baking conditions (204.4 °C for 20, 27, and 34 min) to study the accuracy and precision of gluten measurement by seven immunoassay kits (three LFD and four ELISA kits). The stability and immunoreactivity of gluten proteins, as measured by western blot using three different antibodies, were not adversely affected by the baking conditions. However, the gluten recovery varied depending upon the ELISA kit and the gluten source used to make the incurred cornbread, affecting the accuracy of gluten quantification (BioKits, 9-77%; Morinaga, 91-137%; R-Biopharm, 61-108%; and Romer Labs, 113-190%). Gluten recovery was reduced with increased baking time for most ELISA kits analyzed. Both the sampling and analytical variance increased with an increase in the gluten incurred level. The predicted analytical coefficient of variation associated with all ELISA kits was below 12% for all incurred levels, indicative of good analytical precision.

  7. Evaluation of two strategies for heart health promotion by direct mail in a low-income urban community.

    PubMed

    O'Loughlin, J; Paradis, G; Meshefedjian, G

    1997-01-01

    The objective of this study was to evaluate the reach of mass mailings of heart health education print materials in a low-income, urban community. Materials included a monthly newsletter and a self-help behavior change kit, both distributed to all 12,789 households in the study community. Recall, use, and self-reported impact of the materials were measured in a cross-sectional survey of a random sample of 345 adults conducted 2 weeks after distribution of the kit and 18 months after delivery of the first newsletter. Over one-third of the subjects (38.6%) recalled the newsletter and 27.9% had read one or more newsletters; 21.7% recalled the kit and 10.8% had read it. Few subjects had read both materials. Female gender and older age were independent correlates of having seen and read the newsletters. Older age, being widowed/separated/divorced, and infrequent physical activity were correlates of having seen and read the kit. Although the newsletter and kit formats might appeal to different segments of the population, mass mailings of heart health education print materials in a low-income urban community can reach large numbers of individuals. The cost effectiveness of repeated mailings of short, simple newsletters might be higher than a single mailing of a more complex behavior change kit.

  8. Optimizing direct amplification of forensic commercial kits for STR determination.

    PubMed

    Caputo, M; Bobillo, M C; Sala, A; Corach, D

    2017-04-01

    Direct DNA amplification in forensic genotyping reduces analytical time when large sample sets are being analyzed. The amplification success depends mainly upon two factors: on one hand, the PCR chemistry and, on the other, the type of solid substrate where the samples are deposited. We developed a workflow strategy aiming to optimize times and cost when starting from blood samples spotted onto diverse absorbent substrates. A set of 770 blood samples spotted onto Blood cards, Whatman ® 3 MM paper, FTA™ Classic cards, and Whatman ® Grade 1 was analyzed by a unified working strategy including a low-cost pre-treatment, a PCR amplification volume scale-down, and the use of the 3500 Genetic Analyzer as the analytical platform. Samples were analyzed using three different commercial multiplex STR direct amplification kits. The efficiency of the strategy was evidenced by a higher percentage of high-quality profiles obtained (over 94%), a reduced number of re-injections (average 3.2%), and a reduced amplification failure rate (lower than 5%). Average peak height ratio among different commercial kits was 0.91, and the intra-locus balance showed values ranging from 0.92 to 0.94. A comparison with previously reported results was performed demonstrating the efficiency of the proposed modifications. The protocol described herein showed high performance, producing optimal quality profiles, and being both time and cost effective. Copyright © 2017 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  9. Dual-Targeting of AR and Akt Pathways by Berberine in Castration-Resistant Prostate Cancer

    DTIC Science & Technology

    2015-08-01

    BCA Protein Assay kit (Pierce). The samples were separated on 10% SDS- polyacrylamide gels and transferred onto polyvinylidene fluoride (PVDF...Microtubule/Tubulin In Vivo Assay Kit (Cytoskeleton Inc., Cat.# BK038) following the manufacturer’s instructions. Briefly, 3 × 106 cells were lysed in 4...reporter gene assay . Although the protein fusion affected 193 the relative activities of the fusion proteins (Figs. 1D and S1), all the fusion

  10. Deployment of the DosiKit System Under Operational Conditions: Experience From a French Defense National Nuclear Exercise.

    PubMed

    Entine, F; Bensimon Etzol, J; Bettencourt, C; Dondey, M; Michel, X; Gagna, G; Gellie, G; Corre, Y; Ugolin, N; Chevillard, S; Amabile, J-C

    2018-07-01

    Estimation of the dose received by accidentally irradiated victims is based on a tripod: clinical, biological, and physical dosimetry. The DosiKit system is an operational and mobile biodosimetry device allowing the measurement of external irradiation directly on the site of a radiological accident. This tool is based on capillary blood sample and hair follicle collection. The aim is to obtain a whole-body and local-surface dose assessment. This paper is about the technical evaluation of the DosiKit; the analytical process and scientific validation are briefly described. The Toulon exercise scenario was based on a major accident involving the reactor of a nuclear attack submarine. The design of the scenario made it impossible for several players (firefighters, medical team) to leave the area for a long time, and they were potentially exposed to high dose rates. The DosiKit system was fully integrated into a deployable radiological emergency laboratory, and the response to operational needs was very satisfactory.

  11. Comparing Standard and Selective Degradation DNA Extraction Methods: Results from a Field Experiment with Sexual Assault Kits.

    PubMed

    Campbell, Rebecca; Pierce, Steven J; Sharma, Dhruv B; Shaw, Jessica; Feeney, Hannah; Nye, Jeffrey; Schelling, Kristin; Fehler-Cabral, Giannina

    2017-01-01

    A growing number of U.S. cities have large numbers of untested sexual assault kits (SAKs) in police property facilities. Testing older kits and maintaining current case work will be challenging for forensic laboratories, creating a need for more efficient testing methods. We evaluated selective degradation methods for DNA extraction using actual case work from a sample of previously unsubmitted SAKs in Detroit, Michigan. We randomly assigned 350 kits to either standard or selective degradation testing methods and then compared DNA testing rates and CODIS entry rates between the two groups. Continuation-ratio modeling showed no significant differences, indicating that the selective degradation method had no decrement in performance relative to customary methods. Follow-up equivalence tests indicated that CODIS entry rates for the two methods could differ by more than ±5%. Selective degradation methods required less personnel time for testing and scientific review than standard testing. © 2016 American Academy of Forensic Sciences.

  12. Current molecular profile of juvenile nasopharyngeal angiofibroma: First comprehensive study from India.

    PubMed

    Pandey, Praveen; Mishra, Anupam; Tripathi, Ashoak Mani; Verma, Veerendra; Trivedi, Ritu; Singh, Hitendra Prakash; Kumar, Sunil; Patel, Brijesh; Singh, Vinay; Pandey, Shivani; Pandey, Amita; Mishra, Subhash Chandra

    2017-03-01

    An attempt is made to analyze the molecular behavior of juvenile nasopharyngeal angiofibroma (JNA). Case Series METHODS: Quantification of mRNAs expression was undertaken through real-time polymerase chain reaction in JNA (9-24) samples for VEGF-A, basic fibroblast growth factor (b-FGF), platelet-derived growth factor PDGF-A, KIT proto-oncogene receptor tyrosine kinase (c-Kit), Avian myelomatosis viral oncogene homolog (c-Myc), Harvey rat sarcoma viral oncogene homolog (H-Ras), tumor suppressor gene TP53, and androgen receptor and interleukin 6 (IL-6). The β-catenin expression was evaluated by western blot in 16 samples. Nasal polyp was taken as control. A significantly increased (P < 0.01) expression of c-myc, VEGFA, bFGF, PDGFA, c-kit, and TP53 was seen, along with enhanced expression of β-catenin. A massive enhancement of H-Ras expression was seen for the first time. Androgen receptor expression was no different, whereas IL-6 despite showing upregulation trend was not significant. The enhanced expressions of various markers suggest their potential role in JNA. Although the biological significance of c-kit, c-myc, and one of the novel markers H-Ras has yet to be defined, their significant expression may have a therapeutic importance. NA. Laryngoscope, 127:E100-E106, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  13. Oncogenic mutations in melanomas and benign melanocytic nevi of the female genital tract.

    PubMed

    Tseng, Diane; Kim, Julie; Warrick, Andrea; Nelson, Dylan; Pukay, Marina; Beadling, Carol; Heinrich, Michael; Selim, Maria Angelica; Corless, Christopher L; Nelson, Kelly

    2014-08-01

    The genetic heterogeneity of melanomas and melanocytic nevi of the female genital tract is poorly understood. We aim to characterize the frequency of mutations of the following genes: BRAF, NRAS, KIT, GNA11, and GNAQ in female genital tract melanomas. We also characterize the frequency of BRAF mutations in female genital tract melanomas compared with melanocytic nevi. Mutational screening was performed on the following female genital tract melanocytic neoplasms: 25 melanomas, 7 benign melanocytic nevi, and 4 atypical melanocytic nevi. Of the 25 female genital tract melanoma specimens queried, KIT mutations were detected in 4 (16.0%), NRAS mutations in 4 (16.0%), and BRAF mutations in 2 (8.0%) samples. Two of the tumors with KIT mutations harbored double mutations in the same exon. No GNAQ or GNA11 mutations were identified among 11 melanomas screened. BRAF V600E mutations were detected in 7 of 7 benign melanocytic genital nevi (100%) and 3 of 4 atypical genital nevi (75%). Our study is limited by the small sample size of this rare subset of melanomas. KIT, NRAS, and BRAF mutations are found in a subset of female genital tract melanomas. Screening for oncogenic mutations is important for developing and applying clinical therapies for melanomas of the female genital tract. Copyright © 2014 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  14. Women's views on human papillomavirus self-sampling: focus groups to assess acceptability, invitation letters and a test kit in the Australian setting.

    PubMed

    Sultana, Farhana; Mullins, Robyn; Murphy, Michael; English, Dallas R; Simpson, Julie A; Drennan, Kelly T; Heley, Stella; Wrede, C David; Brotherton, Julia M L; Saville, Marion; Gertig, Dorota M

    2015-08-01

    Background The study evaluated acceptability, invitation letters and the test kit for a trial of human papillomavirus (HPV) self-sampling among never- and under-screened women in Australia. Victorian women, 30-69 years, who had never had a Pap test or were overdue for one, participated. Four focus groups including eight to nine participants segmented by age (30-49 and 50-69 years) and screening history (never- and under-screened) were conducted in August 2013. Discussions were recorded and transcribed verbatim and data analysed using thematic content analysis. The response to the concept of HPV self-sampling was positive. Decision-making was largely influenced by the content of a pre-invitation letter. Appealing features of self-sampling were cost (free), convenience (home-based) and anticipated less discomfort (with a swab) than a Pap test. Small kits that fit in mailboxes were preferred over post office parcel collection. The perceived barriers include concerns about test accuracy and lack of confidence that a home-based test would give the same results as a physician administered test. Women wanted information on the timing of receipt of the results and information about the organisation providing the test. HPV self-sampling is a possible alternative for Australian women who are reluctant to have a Pap test and may increase the likelihood of participation in cervical cancer screening if women's concerns about it can be addressed. The findings of this study are relevant for researchers, policymakers and practitioners implementing self-sampling for under-screened women as part of cervical screening programs.

  15. Human Papillomavirus Infection in Women Who Submit Self-collected Vaginal Swabs After Internet Recruitment.

    PubMed

    Nelson, Erik J; Hughes, John; Oakes, J Michael; Thyagarajan, Bharat; Pankow, James S; Kulasingam, Shalini L

    2015-06-01

    Submission of vaginal samples collected at home could remove barriers that women face in getting screened for cervical cancer. From December 2013 to January 2014, women aged 21-30 years were recruited online to participate in either (1) self-collected testing for human papillomavirus (HPV) infection and an online survey, or (2) an online survey regarding their perceptions of self-collected testing for HPV infection. Demographics, risk factors, testing perceptions, and satisfaction with self-collected testing were assessed with online questionnaires. Women who performed self-collection were sent a home sampling kit by US mail, which was returned via US mail for HPV testing. A total of 197 women were enrolled, with 130 completing the online survey and 67 participating in both the survey and self-collection. Of the 67 women who were sent kits, 62 (92.5%) were returned for testing. Sixty kits contained a sample sufficient for testing. The overall prevalence of HPV infection was 17.8%, however 6 women (9.7%) were infected with >1 type of HPV. Women who self-collected a sample reported more favorable attributes of self-collection compared to women who only participated in the online survey, including ease of sampling (87.1 vs. 18.9%), no pain during sampling (72.6 vs. 5.6%), and lack of embarrassment (67.7 vs. 12.9%). A high prevalence of HPV infection was demonstrated among women recruited via the internet. Online recruitment and at home screening methods have the potential to engage women in screening by offering an approach that might be more acceptable to women of different backgrounds.

  16. Comparing rapid methods for detecting Listeria in seafood and environmental samples using the most probably number (MPN) technique.

    PubMed

    Cruz, Cristina D; Win, Jessicah K; Chantarachoti, Jiraporn; Mutukumira, Anthony N; Fletcher, Graham C

    2012-02-15

    The standard Bacteriological Analytical Manual (BAM) protocol for detecting Listeria in food and on environmental surfaces takes about 96 h. Some studies indicate that rapid methods, which produce results within 48 h, may be as sensitive and accurate as the culture protocol. As they only give presence/absence results, it can be difficult to compare the accuracy of results generated. We used the Most Probable Number (MPN) technique to evaluate the performance and detection limits of six rapid kits for detecting Listeria in seafood and on an environmental surface compared with the standard protocol. Three seafood products and an environmental surface were inoculated with similar known cell concentrations of Listeria and analyzed according to the manufacturers' instructions. The MPN was estimated using the MPN-BAM spreadsheet. For the seafood products no differences were observed among the rapid kits and efficiency was similar to the BAM method. On the environmental surface the BAM protocol had a higher recovery rate (sensitivity) than any of the rapid kits tested. Clearview™, Reveal®, TECRA® and VIDAS® LDUO detected the cells but only at high concentrations (>10(2) CFU/10 cm(2)). Two kits (VIP™ and Petrifilm™) failed to detect 10(4) CFU/10 cm(2). The MPN method was a useful tool for comparing the results generated by these presence/absence test kits. There remains a need to develop a rapid and sensitive method for detecting Listeria in environmental samples that performs as well as the BAM protocol, since none of the rapid tests used in this study achieved a satisfactory result. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Quantitative analysis of fungicide azoxystrobin in agricultural samples with rapid, simple and reliable monoclonal immunoassay.

    PubMed

    Watanabe, Eiki; Miyake, Shiro

    2013-01-15

    This work presents analytical performance of a kit-based direct competitive enzyme-linked immunosorbent assay (dc-ELISA) for azoxystrobin detection in agricultural products. The dc-ELISA was sufficiently sensitive for analysis of residue levels close to the maximum residue limits. The dc-ELISA did not show cross-reactivity to other strobilurin analogues. Absorbance decreased with the increase of methanol concentration in sample solution from 2% to 40%, while the standard curve became most linear when the sample solution contained 10% methanol. Agricultural samples were extracted with methanol, and the extracts were diluted with water to 10% methanol adequate. No significant matrix interference was observed. Satisfying recovery was found for all of spiked samples and the results were well agreed with the analysis with liquid chromatography. These results clearly indicate that the kit-based dc-ELISA is suitable for the rapid, simple, quantitative and reliable determination of the fungicide. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Molecular Diagnosis of Invasive Aspergillosis and Detection of Azole Resistance by a Newly Commercialized PCR Kit

    PubMed Central

    Gabriel, Frédéric; Gaboyard, Manuel; Lagardere, Gaëlle; Audebert, Lucile; Quesne, Gilles; Godichaud, Sandrine; Verweij, Paul E.; Accoceberry, Isabelle

    2017-01-01

    ABSTRACT Aspergillus fumigatus is the main species responsible for aspergillosis in humans. The diagnosis of aspergillosis remains difficult, and the rapid emergence of azole resistance in A. fumigatus is worrisome. The aim of this study was to validate the new MycoGENIE A. fumigatus real-time PCR kit and to evaluate its performance on clinical samples for the detection of A. fumigatus and its azole resistance. This multiplex assay detects DNA from the A. fumigatus species complex by targeting the multicopy 28S rRNA gene and specific TR34 and L98H mutations in the single-copy-number cyp51A gene of A. fumigatus. The specificity of cyp51A mutation detection was assessed by testing DNA samples from 25 wild-type or mutated clinical A. fumigatus isolates. Clinical validation was performed on 88 respiratory samples obtained from 62 patients and on 69 serum samples obtained from 16 patients with proven or probable aspergillosis and 13 patients without aspergillosis. The limit of detection was <1 copy for the Aspergillus 28S rRNA gene and 6 copies for the cyp51A gene harboring the TR34 and L98H alterations. No cross-reactivity was detected with various fungi and bacteria. All isolates harboring the TR34 and L98H mutations were accurately detected by quantitative PCR (qPCR) analysis. With respiratory samples, qPCR results showed a sensitivity and specificity of 92.9% and 90.1%, respectively, while with serum samples, the sensitivity and specificity were 100% and 84.6%, respectively. Our study demonstrated that this new real-time PCR kit enables sensitive and rapid detection of A. fumigatus DNA and azole resistance due to TR34 and L98H mutations in clinical samples. PMID:28814586

  19. TECHNOLOGIES FOR MONITORING AND MEASUREMENT ...

    EPA Pesticide Factsheets

    A demonstration of technologies for determining the presence of dioxin and dioxin-like compounds in soil and sediment was conducted under EPA's Superfund Innovative Technology Evaluation Program in Saginaw, Michigan in April 2004. This report describes the performance evaluation of the Abraxis LLC Coplanar PCB Enzyme-Linked Immunosorbent Assay (ELISA) kit. The kit is an immunoassay technique that reports the total toxicity equivalents (TEQ) of polychlorinated biphenyls (PCBs). The technology results were compared to high resolution mass spectrometry TEQ results generated using EPA Method 1668A.Abraxis generally reported data that were higher than the reference laboratory TEQPCB values, with the exception of ultra-high level PCB samples [> 10,000 picogram/gram (pg/g) TEQ] where Abraxis reported values lower than the reference method. The technologys estimated MDL was 6 to 31 pg/g TEQPCB. Results from this demonstration suggest that the Abraxis kit could be an effective screening tool for screening sample concentrations above and below 50 pg/g TEQPCB, particularly considering that the cost ($22,668 vs. $184,449) and the time to analyze the 209 demonstration samples were significantly less than those of the reference laboratory. The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented performance and cost data obtained from field demonstrations.

  20. Platelet collection efficiencies of three different platelet-rich plasma preparation systems.

    PubMed

    Aydin, Fatma; Pancar Yuksel, Esra; Albayrak, Davut

    2015-06-01

    Different systems have been used for the preparation of platelet-rich plasma (PRP), but platelet collection efficiencies of these systems are not clear. To evaluate the platelet collection efficiencies of three different PRP preparation systems. Blood samples were obtained from the same 16 volunteers for each system. The samples were centrifuged and PRP was prepared by three systems. The ratio of the total number of platelets in PRP to the total number of platelets of the venous blood sample of the patient expressed in percentage was named as platelet collection efficiency and calculated for each system. Mean platelet collection efficiencies were 66.6 (min: 56.9, max: 76.9), 58.3 (min: 27.3, max: 102.8), 50.8 (min: 27.2, max: 73) for top and bottom bag system, system using citrated tube, and the system using tube with Ficoll and cell extraction kit, respectively. Statistically significant difference was found only between the platelet collection efficiencies of systems using the tube with ficoll and cell extraction kit and the top and bottom bag system (p = 0.002). All three systems could be used for PRP preparation, but top and bottom bag system offers a slight advantage over the system using Ficoll and cell extraction kit regarding the platelet collection efficiency.

  1. HIV-1 and HCV viral load cost models for bDNA: 440 Molecular System versus real-time PCR AmpliPrep/TaqMan test.

    PubMed

    Elbeik, Tarek; Dalessandro, Ralph; Loftus, Richard A; Beringer, Scott

    2007-11-01

    Comparative cost models were developed to assess cost-per-reportable result and annual costs for HIV-1 and HCV bDNA and AmpliPrep/TaqMan Test (PCR). Model cost components included kit, disposables, platform and related equipment, equipment service plan, equipment maintenance, equipment footprint, waste and labor. Model assessment was most cost-effective when run by bDNA with 36 or more clinical samples and PCR with 30 or fewer clinical samples. Lower costs are attained with maximum samples (84-168) run daily. Highest cost contributors include kit, platform and PCR proprietary disposables. Understanding component costs and the most economic use of HIV-1 and HCV viral load will aid in attaining lowest costs through selection of the appropriate assay and effective negotiations.

  2. Transparent DNA/RNA Co-extraction Workflow Protocol Suitable for Inhibitor-Rich Environmental Samples That Focuses on Complete DNA Removal for Transcriptomic Analyses

    PubMed Central

    Lim, Natalie Y. N.; Roco, Constance A.; Frostegård, Åsa

    2016-01-01

    Adequate comparisons of DNA and cDNA libraries from complex environments require methods for co-extraction of DNA and RNA due to the inherent heterogeneity of such samples, or risk bias caused by variations in lysis and extraction efficiencies. Still, there are few methods and kits allowing simultaneous extraction of DNA and RNA from the same sample, and the existing ones generally require optimization. The proprietary nature of kit components, however, makes modifications of individual steps in the manufacturer’s recommended procedure difficult. Surprisingly, enzymatic treatments are often performed before purification procedures are complete, which we have identified here as a major problem when seeking efficient genomic DNA removal from RNA extracts. Here, we tested several DNA/RNA co-extraction commercial kits on inhibitor-rich soils, and compared them to a commonly used phenol-chloroform co-extraction method. Since none of the kits/methods co-extracted high-quality nucleic acid material, we optimized the extraction workflow by introducing small but important improvements. In particular, we illustrate the need for extensive purification prior to all enzymatic procedures, with special focus on the DNase digestion step in RNA extraction. These adjustments led to the removal of enzymatic inhibition in RNA extracts and made it possible to reduce genomic DNA to below detectable levels as determined by quantitative PCR. Notably, we confirmed that DNase digestion may not be uniform in replicate extraction reactions, thus the analysis of “representative samples” is insufficient. The modular nature of our workflow protocol allows optimization of individual steps. It also increases focus on additional purification procedures prior to enzymatic processes, in particular DNases, yielding genomic DNA-free RNA extracts suitable for metatranscriptomic analysis. PMID:27803690

  3. Comparative Study of Seven Commercial Kits for Human DNA Extraction from Urine Samples Suitable for DNA Biomarker-Based Public Health Studies

    PubMed Central

    El Bali, Latifa; Diman, Aurélie; Bernard, Alfred; Roosens, Nancy H. C.; De Keersmaecker, Sigrid C. J.

    2014-01-01

    Human genomic DNA extracted from urine could be an interesting tool for large-scale public health studies involving characterization of genetic variations or DNA biomarkers as a result of the simple and noninvasive collection method. These studies, involving many samples, require a rapid, easy, and standardized extraction protocol. Moreover, for practicability, there is a necessity to collect urine at a moment different from the first void and to store it appropriately until analysis. The present study compared seven commercial kits to select the most appropriate urinary human DNA extraction procedure for epidemiological studies. DNA yield has been determined using different quantification methods: two classical, i.e., NanoDrop and PicoGreen, and two species-specific real-time quantitative (q)PCR assays, as DNA extracted from urine contains, besides human, microbial DNA also, which largely contributes to the total DNA yield. In addition, the kits giving a good yield were also tested for the presence of PCR inhibitors. Further comparisons were performed regarding the sampling time and the storage conditions. Finally, as a proof-of-concept, an important gene related to smoking has been genotyped using the developed tools. We could select one well-performing kit for the human DNA extraction from urine suitable for molecular diagnostic real-time qPCR-based assays targeting genetic variations, applicable to large-scale studies. In addition, successful genotyping was possible using DNA extracted from urine stored at −20°C for several months, and an acceptable yield could also be obtained from urine collected at different moments during the day, which is particularly important for public health studies. PMID:25365790

  4. Evaluation of the Aspergillus Western Blot IgG Kit for Diagnosis of Chronic Aspergillosis

    PubMed Central

    Oliva, A.; Flori, P.; Hennequin, C.; Dubus, J.-C.; Reynaud-Gaubert, M.; Charpin, D.; Vergnon, J. M.; Gay, P.; Colly, A.; Piarroux, R.; Pelloux, H.

    2014-01-01

    Immunoprecipitin detection (IPD) is the current reference confirmatory technique for anti-Aspergillus antibody detection; however, the lack of standardization is a critical drawback of this assay. In this study, we evaluated the performance of the Aspergillus Western blot (Asp-WB) IgG kit (LDBio Diagnostics, Lyon, France), a recently commercialized immunoblot assay for the diagnosis of various clinical presentations of chronic aspergillosis. Three hundred eight serum samples from 158 patients with aspergillosis sensu lato (s.l.) were analyzed. More specifically, 267 serum samples were derived from patients with Aspergillus disease, including 89 cases of chronic pulmonary aspergillosis, 10 of aspergilloma, and 32 of allergic bronchopulmonary aspergillosis, while 41 samples were from patients with Aspergillus colonization, including 15 cystic fibrosis (CF) and 12 non-CF patients. For blood donor controls, the Asp-WB specificity was 94%, while the kit displayed a sensitivity for the aspergillosis s.l. diagnosis of 88.6%, with a diagnostic odds ratio (DOR) of 119 (95% confidence interval [CI], 57 to 251). The DOR values were 185.22 (95% CI,78.79 to 435.45) and 43.74 (95% CI, 15.65 to 122.20) for the diagnosis of Aspergillus disease and Aspergillus colonization, respectively. Among the patients, the sensitivities of the Asp-WB in the diagnosis of Aspergillus colonization were 100% and 41.7% in CF and non-CF patients, respectively. The Asp-WB yielded fewer false-negative results than did IPD. In conclusion, the Asp-WB kit performed well for the diagnosis of various clinical presentations of aspergillosis in nonimmunocompromised patients, with an enhanced standardization and a higher sensitivity than with IPD, which is the current reference method. PMID:25392351

  5. Evaluation of the Aspergillus Western blot IgG kit for diagnosis of chronic aspergillosis.

    PubMed

    Oliva, A; Flori, P; Hennequin, C; Dubus, J-C; Reynaud-Gaubert, M; Charpin, D; Vergnon, J M; Gay, P; Colly, A; Piarroux, R; Pelloux, H; Ranque, S

    2015-01-01

    Immunoprecipitin detection (IPD) is the current reference confirmatory technique for anti-Aspergillus antibody detection; however, the lack of standardization is a critical drawback of this assay. In this study, we evaluated the performance of the Aspergillus Western blot (Asp-WB) IgG kit (LDBio Diagnostics, Lyon, France), a recently commercialized immunoblot assay for the diagnosis of various clinical presentations of chronic aspergillosis. Three hundred eight serum samples from 158 patients with aspergillosis sensu lato (s.l.) were analyzed. More specifically, 267 serum samples were derived from patients with Aspergillus disease, including 89 cases of chronic pulmonary aspergillosis, 10 of aspergilloma, and 32 of allergic bronchopulmonary aspergillosis, while 41 samples were from patients with Aspergillus colonization, including 15 cystic fibrosis (CF) and 12 non-CF patients. For blood donor controls, the Asp-WB specificity was 94%, while the kit displayed a sensitivity for the aspergillosis s.l. diagnosis of 88.6%, with a diagnostic odds ratio (DOR) of 119 (95% confidence interval [CI], 57 to 251). The DOR values were 185.22 (95% CI,78.79 to 435.45) and 43.74 (95% CI, 15.65 to 122.20) for the diagnosis of Aspergillus disease and Aspergillus colonization, respectively. Among the patients, the sensitivities of the Asp-WB in the diagnosis of Aspergillus colonization were 100% and 41.7% in CF and non-CF patients, respectively. The Asp-WB yielded fewer false-negative results than did IPD. In conclusion, the Asp-WB kit performed well for the diagnosis of various clinical presentations of aspergillosis in nonimmunocompromised patients, with an enhanced standardization and a higher sensitivity than with IPD, which is the current reference method. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  6. The characterization of four gene expression analysis in circulating tumor cells made by Multiplex-PCR from the AdnaTest kit on the lab-on-a-chip Agilent DNA 1000 platform.

    PubMed

    Škereňová, Markéta; Mikulová, Veronika; Čapoun, Otakar; Zima, Tomáš

    2016-01-01

    Nowadays, on-a-chip capillary electrophoresis is a routine method for the detection of PCR fragments. The Agilent 2100 Bioanalyzer was one of the first commercial devices in this field. Our project was designed to study the characteristics of Agilent DNA 1000 kit in PCR fragment analysis as a part of circulating tumour cell (CTC) detection technique. Despite the common use of this kit a complex analysis of the results from a long-term project is still missing. A commercially available Agilent DNA 1000 kit was used as a final step in the CTC detection (AdnaTest) for the determination of the presence of PCR fragments generated by Multiplex PCR. Data from 30 prostate cancer patients obtained during two years of research were analyzed to determine the trueness and precision of the PCR fragment size determination. Additional experiments were performed to demonstrate the precision (repeatability, reproducibility) and robustness of PCR fragment concentration determination. The trueness and precision of the size determination was below 3% and 2% respectively. The repeatability of the concentration determination was below 15%. The difference in concentration determination increases when Multiplex-PCR/storage step is added between the two measurements of one sample. The characteristics established in our study are in concordance with the manufacturer's specifications established for a ladder as a sample. However, the concentration determination may vary depending on chip preparation, sample storage and concentration. The 15% variation of concentration determination repeatability was shown to be partly proportional and can be suppressed by proper normalization.

  7. Performance Evaluation of the Bioneer AccuPower® HIV-1 Quantitative RT-PCR kit: Comparison with the Roche COBAS® AmpliPrep/COBAS TaqMan® HIV-1 Test Ver.2.0 for Quantification of HIV-1 Viral Load in Indonesia.

    PubMed

    Kosasih, Agus Susanto; Sugiarto, Christine; Hayuanta, Hubertus Hosti; Juhaendi, Runingsih; Setiawan, Lyana

    2017-08-08

    Measurement of viral load in human immunodeficiency virus type 1 (HIV-1) infected patients is essential for the establishment of a therapeutic strategy. Several assays based on qPCR are available for the measurement of viral load; they differ in sample volume, technology applied, target gene, sensitivity and dynamic range. The Bioneer AccuPower® HIV-1 Quantitative RT-PCR is a novel commercial kit that has not been evaluated for its performance. This study aimed to evaluate the performance of the Bioneer AccuPower® HIV-1 Quantitative RT-PCR kit. In total, 288 EDTA plasma samples from the Dharmais Cancer Hospital were analyzed with the Bioneer AccuPower® HIV-1 Quantitative RT-PCR kit and the Roche COBAS? AmpliPrep/COBAS® TaqMan® HIV-1 version 2.0 (CAP/CTM v2.0). The performance of the Bioneer assay was then evaluated against the Roche CAP/CTM v2.0. Overall, there was good agreement between the two assays. The Bioneer assay showed significant linear correlation with CAP/CTM v2.0 (R2=0.963, p<0.001) for all samples (N=118) which were quantified by both assays, with high agreement (94.9%, 112/118) according to the Bland-Altman model. The mean difference between the quantitative values measured by Bioneer assay and CAP/CTM v2.0 was 0.11 Log10 IU/mL (SD=0.26). Based on these results, the Bioneer assay can be used to quantify HIV-1 RNA in clinical laboratories.

  8. Evaluation of the performance of the IQ-check kits and the USDA microbiology laboratory guidebook methods for detection of Shiga Toxin-Producing E. coli (STEC) and STEC and Salmonella simultaneously in ground beef

    USDA-ARS?s Scientific Manuscript database

    Aims: To evaluate the performance of the IQ-Check kits and the USDA Microbiology Laboratory Guidebook (MLG) methods for detection of the top 7 Shiga toxin-producing E. coli (STEC) (O157:H7, O26, O45, O103, O111, O121, and O145) in ground beef and both STEC and Salmonella in co-inoculated samples. M...

  9. Evaluation of Presto(plus) assay and LightMix kit Trichomonas vaginalis assay for detection of Trichomonas vaginalis in dry vaginal swabs.

    PubMed

    de Waaij, Dewi J; Ouburg, Sander; Dubbink, Jan Henk; Peters, Remco P H; Morré, Servaas A

    2016-08-01

    This is an evaluation study of the Presto(plus) Assay for T. vaginalis by comparing to the TIB MOLBIOL LightMix Kit Trichomonas vaginalis Assay using 615 dry collected vaginal and rectal swabs. Discordant samples were analyzed by the Qiagen® Microbial DNA qPCR for TV Assay. Both assays showed comparable performances (McNemar p>0.05). Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Nonenzymatic catalytic signal amplification for nucleic acid hybridization assays

    NASA Technical Reports Server (NTRS)

    Fan, Wenhong (Inventor); Han, Jie (Inventor); Cassell, Alan M. (Inventor)

    2006-01-01

    Devices, methods, and kits for amplifying the signal from hybridization reactions between nucleic acid probes and their cognate targets are presented. The devices provide partially-duplexed, immobilized probe complexes, spatially separate from and separately addressable from immobilized docking strands. Cognate target acts catalytically to transfer probe from the site of probe complex immobilization to the site of immobilized docking strand, generating a detectable signal. The methods and kits of the present invention may be used to identify the presence of cognate target in a fluid sample.

  11. Commercial test kits for detection of Lyme borreliosis: a meta-analysis of test accuracy

    PubMed Central

    Cook, Michael J; Puri, Basant K

    2016-01-01

    The clinical diagnosis of Lyme borreliosis can be supported by various test methodologies; test kits are available from many manufacturers. Literature searches were carried out to identify studies that reported characteristics of the test kits. Of 50 searched studies, 18 were included where the tests were commercially available and samples were proven to be positive using serology testing, evidence of an erythema migrans rash, and/or culture. Additional requirements were a test specificity of ≥85% and publication in the last 20 years. The weighted mean sensitivity for all tests and for all samples was 59.5%. Individual study means varied from 30.6% to 86.2%. Sensitivity for each test technology varied from 62.4% for Western blot kits, and 62.3% for enzyme-linked immunosorbent assay tests, to 53.9% for synthetic C6 peptide ELISA tests and 53.7% when the two-tier methodology was used. Test sensitivity increased as dissemination of the pathogen affected different organs; however, the absence of data on the time from infection to serological testing and the lack of standard definitions for “early” and “late” disease prevented analysis of test sensitivity versus time of infection. The lack of standardization of the definitions of disease stage and the possibility of retrospective selection bias prevented clear evaluation of test sensitivity by “stage”. The sensitivity for samples classified as acute disease was 35.4%, with a corresponding sensitivity of 64.5% for samples from patients defined as convalescent. Regression analysis demonstrated an improvement of 4% in test sensitivity over the 20-year study period. The studies did not provide data to indicate the sensitivity of tests used in a clinical setting since the effect of recent use of antibiotics or steroids or other factors affecting antibody response was not factored in. The tests were developed for only specific Borrelia species; sensitivities for other species could not be calculated. PMID:27920571

  12. Genetic profile of a multi-ethnic population from Guiné-Bissau (west African coast) using the new PowerPlex 16 System kit.

    PubMed

    Gonçalves, Rita; Jesus, José; Fernandes, Ana Teresa; Brehm, António

    2002-09-10

    Allele and haplotype frequencies of 15 chromosome STR loci included in the kit PowerPlex16 System from Promega, were determined in a sample of unrelated males from Guiné-Bissau, a country from the west African coast. All individuals were subjected to an interview in order to make sure that their ancestors belonged to the same ethnic group. This way we intended to look for possible inter-ethnic differences. PowerPlex 16 includes STRs not studied before in any multi-ethnic population. The kit includes two new allele markers (Penta D and Penta E), which are very useful either in forensics or population genetic studies. The Guinean population presents significant differences when compared with other African populations.

  13. Development and testing of monoclonal antibody-based rapid immunodiagnostic test kits for direct detection of Vibrio cholerae O139 synonym Bengal.

    PubMed

    Hasan, J A; Huq, A; Nair, G B; Garg, S; Mukhopadhyay, A K; Loomis, L; Bernstein, D; Colwell, R R

    1995-11-01

    We report on the development and testing of two monoclonal antibody-based rapid immunodiagnostic test kits, BengalScreen, a coagglutination test, and Bengal DFA, a direct fluorescent-antibody test, for direct detection of Vibrio cholerae O139 synonym Bengal in clinical and environmental specimens. The BengalScreen test requires less than 5 min to complete and can be used in the field. Bengal DFA, being more sensitive than BengalScreen, requires only one reagent and less than 20 min for detection and enumeration of V. cholerae O139 synonym Bengal. In tests for specificity, all 40 strains of V. cholerae O139 reacted with both test kits, whereas 157 strains of heterologous species examined did not, yielding 100% specificity in this study. A field trial was conducted in with both BengalScreen and Bengal DFA, and the results were compared with those obtained by conventional culture methods. BengalScreen demonstrated a sensitivity of 95%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 94%. Results obtained by Bengal DFA, on the other hand, were 100% sensitive and 100% specific and yielded 100% positive and negative predictive values compared with culture methods. In a second evaluation, 93 stool specimens from Mexico that were negative for V. cholerae O139 by culture were also tested with both the BengalScreen and Bengal DFA kits. None of the 93 specimens were positive for V. cholerae O139 by both tests. A concentration method was optimized for screening of environmental water samples for V. cholerae O139 synonym Bengal with rapid test kits. BengalScreen results were unequivocally positive when water samples contained at least 2.0 x 10(3) CFU/ml, whereas Bengal DFA demonstrated an unequivocally positive reaction when the water sample contained at least 1.5 x 10(2) CFU/ml. When Bengal DFA was compared with conventional culture methods for enumeration of V. cholerae O139 synonym Bengal organisms, no difference was observed.

  14. Effect of Temperature and Time on Fecal Hemoglobin Stability in 5 Fecal Immunochemical Test Methods and One Guaiac Method.

    PubMed

    Catomeris, Peter; Baxter, Nancy N; Boss, Sheila C; Paszat, Lawrence F; Rabeneck, Linda; Randell, Edward; Serenity, Mardie L; Sutradhar, Rinku; Tinmouth, Jill

    2018-01-01

    - Although promising for colorectal cancer screening, hemoglobin (Hb) stability remains a concern with fecal immunochemical tests. This study implemented a novel, standardized method to compare Hb stability across various fecal immunochemical tests. The method can be used to inform decisions when selecting a kit for use in colorectal cancer screening. In so doing, this work addressed a critical need for standardization in this field. - To compare the stability of Hb across 5 different immunochemical kits and one guaiac kit. - The stability of Hb was analyzed in collection devices inoculated with Hb-spiked feces and (1) stored at various temperatures (frozen, refrigerated, ambient, and elevated) for more than 60 days; (2) after undergoing 3 controlled, freeze-thaw cycles; and (3) after being transported by courier or postal services in uncontrolled temperature conditions from 3 locations in Ontario, Canada, to a central testing center. - The stability of Hb varied with time and temperature and by kit. Lower Hb recoveries occurred with increasing temperature and increasing time from sample collection to testing. Refrigeration provided the best stability, although results varied across kits (eg, from 4.2 days to >60 days before a prespecified threshold [<70% probability of the test results remaining positive] was reached). Freeze-thaw stability varied across kits and cycles (Hb recoveries: NS Plus [Alfresa Pharma, Chuo-ku, Osaka, Japan], 91.7% to 95.4%; OC Diana [Eiken Chemical, Taito-ku, Tokyo, Japan], 57.6% to 74.9%). Agreement regarding Hb levels before and after transportation varied across kits (from 57% to 100%). - Important differences in Hb stability were found across the included fecal immunochemical tests. These findings should inform practice-based and population-based colorectal cancer screening.

  15. Evaluation of digital PCR for absolute RNA quantification.

    PubMed

    Sanders, Rebecca; Mason, Deborah J; Foy, Carole A; Huggett, Jim F

    2013-01-01

    Gene expression measurements detailing mRNA quantities are widely employed in molecular biology and are increasingly important in diagnostic fields. Reverse transcription (RT), necessary for generating complementary DNA, can be both inefficient and imprecise, but remains a quintessential RNA analysis tool using qPCR. This study developed a Transcriptomic Calibration Material and assessed the RT reaction using digital (d)PCR for RNA measurement. While many studies characterise dPCR capabilities for DNA quantification, less work has been performed investigating similar parameters using RT-dPCR for RNA analysis. RT-dPCR measurement using three, one-step RT-qPCR kits was evaluated using single and multiplex formats when measuring endogenous and synthetic RNAs. The best performing kit was compared to UV quantification and sensitivity and technical reproducibility investigated. Our results demonstrate assay and kit dependent RT-dPCR measurements differed significantly compared to UV quantification. Different values were reported by different kits for each target, despite evaluation of identical samples using the same instrument. RT-dPCR did not display the strong inter-assay agreement previously described when analysing DNA. This study demonstrates that, as with DNA measurement, RT-dPCR is capable of accurate quantification of low copy RNA targets, but the results are both kit and target dependent supporting the need for calibration controls.

  16. Availability, Accessibility, and Price of Rapid HIV Self-Tests, New York City Pharmacies, Summer 2013.

    PubMed

    Myers, Julie E; El-Sadr Davis, Olivia Y; Weinstein, Elliott R; Remch, Molly; Edelstein, Amy; Khawja, Amina; Schillinger, Julia A

    2017-02-01

    We conducted an in-person survey of New York City (NYC) pharmacies to assess the availability, accessibility, and price of the over-the-counter, rapid HIV self-test kit. NYC pharmacies were stratified into high, moderate and low morbidity neighborhoods by the HIV diagnosis rate of the neighborhood in which the pharmacy was located. A random sample of 500 pharmacies was taken [250 from high morbidity neighborhoods (HighMN) and 250 from low morbidity neighborhoods (LowMN)]. Pharmacies were excluded if: closed during survey, non-retail, or >10 min walk from subway. Project staff visited pharmacies to determine kit availability (in pharmacy on day of survey), accessibility (not locked/behind counter), and price (marked on shelf/product). Of 361 pharmacies (161 LowMN; 200 HighMN), kits were available in 27 % and accessible in 10 %; there was no difference by neighborhood. Kits were most often kept behind the pharmacy counter; this was more common in HighMN than in LowMN. Kits were kept solely behind the pharmacy counter in 52 %. Median price was US $42.99 without variability across neighborhoods. The rapid HIV self-test had limited availability and access in retail pharmacies. The high median price measured suggests that cost remained a barrier.

  17. Loss of Function of TET2 Cooperates with Constitutively Active KIT in Murine and Human Models of Mastocytosis

    PubMed Central

    De Vita, Serena; Schneider, Rebekka K.; Garcia, Michael; Wood, Jenna; Gavillet, Mathilde; Ebert, Benjamin L.; Gerbaulet, Alexander; Roers, Axel; Levine, Ross L.; Mullally, Ann; Williams, David A.

    2014-01-01

    Systemic Mastocytosis (SM) is a clonal disease characterized by abnormal accumulation of mast cells in multiple organs. Clinical presentations of the disease vary widely from indolent to aggressive forms, and to the exceedingly rare mast cell leukemia. Current treatment of aggressive SM and mast cell leukemia is unsatisfactory. An imatinib-resistant activating mutation of the receptor tyrosine kinase KIT (KIT D816V) is most frequently present in transformed mast cells and is associated with all clinical forms of the disease. Thus the etiology of the variable clinical aggressiveness of abnormal mast cells in SM is unclear. TET2 appears to be mutated in primary human samples in aggressive types of SM, suggesting a possible role in disease modification. In this report, we demonstrate the cooperation between KIT D816V and loss of function of TET2 in mast cell transformation and demonstrate a more aggressive phenotype in a murine model of SM when both mutations are present in progenitor cells. We exploit these findings to validate a combination treatment strategy targeting the epigenetic deregulation caused by loss of TET2 and the constitutively active KIT receptor for the treatment of patients with aggressive SM. PMID:24788138

  18. Sample Collection for the Russian Biodegradatsiya Experiment

    NASA Image and Video Library

    2007-10-01

    ISS015-E-32031 (October 2007) --- Cosmonaut Oleg V. Kotov, Expedition 15 flight engineer representing Russia's Federal Space Agency, uses a Bioproby Kit to collect surface samples for analysis for the Russian Biodegradation experiment in the Zvezda Service Module of the International Space Station.

  19. mRNA Expression of Platelet-Derived Growth Factor Receptor-{beta} and C-KIT: Correlation With Pathologic Response to Cetuximab-Based Chemoradiotherapy in Patients With Rectal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erben, Philipp; Horisberger, Karoline; Muessle, Benjamin

    2008-12-01

    Purpose: Deviant expression of platelet-derived growth factor receptor-{beta} (PDGFR{beta}) and c-kit was shown in patients with colorectal cancer. In the present study, mRNA expression of PDGFR{beta} and c-kit in 33 patients with locally advanced rectal cancer undergoing preoperative chemoradiotherapy with cetuximab/capecitabine/irinotecan in correlation with the tumor regression rate was investigated. Methods and Materials: Pretherapeutic biopsy cores and tumor material from the resected specimens were collected in parallel with normal rectal mucosa. The expression levels of PDGFR{beta} and c-kit were measured by quantitative polymerase chain reaction. Tumors were classified as good responders (tumor regression grade [TRG], 2-3) or poor responders (TRG,more » 0-1). Results: The TRG evaluation of the resected specimen was TRG 0-1 in 11 and TRG 2-3 in 22. The median normalized ratios in the pretreatment mucosa vs. tumor biopsy cores was as follows: PDGFR{beta} ratio of 15.2 vs. 49.5 (p <0.0001) and c-kit ratio of 0.94 vs. 0.67 (p = 0.014). The same tendency was observed for the median PDGFR{beta} ratios after chemoradiotherapy completion: 34.2 vs. 170.0 (p <0.0001). The PDGFR{beta} and c-kit mRNA expression values in the pretreatment tumor biopsy cores were lower than the values in the resected specimens: PDGFR{beta} ratio 49.5 vs. 170.0 (p = 0.0002) and c-kit ratio 0.67 vs. 1.1 (p = 0.0003). Nevertheless, no correlation was seen between the pretherapeutic PDGFR{beta} and c-kit mRNA expression and the pathologic regression rate. Conclusion: Cetuximab-based chemoradiotherapy increased PDGFR{beta} levels even further compared with the pretreatment samples and deserves further investigation.« less

  20. Optimization of a metatranscriptomic approach to study the lignocellulolytic potential of the higher termite gut microbiome.

    PubMed

    Marynowska, Martyna; Goux, Xavier; Sillam-Dussès, David; Rouland-Lefèvre, Corinne; Roisin, Yves; Delfosse, Philippe; Calusinska, Magdalena

    2017-09-01

    Thanks to specific adaptations developed over millions of years, the efficiency of lignin, cellulose and hemicellulose decomposition of higher termite symbiotic system exceeds that of many other lignocellulose utilizing environments. Especially, the examination of its symbiotic microbes should reveal interesting carbohydrate-active enzymes, which are of primary interest for the industry. Previous metatranscriptomic reports (high-throughput mRNA sequencing) highlight the high representation and overexpression of cellulose and hemicelluloses degrading genes in the termite hindgut digestomes, indicating the potential of this technology in search for new enzymes. Nevertheless, several factors associated with the material sampling and library preparation steps make the metatranscriptomic studies of termite gut prokaryotic symbionts challenging. In this study, we first examined the influence of the sampling strategy, including the whole termite gut and luminal fluid, on the diversity and the metatranscriptomic profiles of the higher termite gut symbiotic bacteria. Secondly, we evaluated different commercially available kits combined in two library preparative pipelines for the best bacterial mRNA enrichment strategy. We showed that the sampling strategy did not significantly impact the generated results, both in terms of the representation of the microbes and their transcriptomic profiles. Nevertheless collecting luminal fluid reduces the co-amplification of unwanted RNA species of host origin. Furthermore, for the four studied higher termite species, the library preparative pipeline employing Ribo-Zero Gold rRNA Removal Kit "Epidemiology" in combination with Poly(A) Purist MAG kit resulted in a more efficient rRNA and poly-A-mRNAdepletion (up to 98.44% rRNA removed) than the pipeline utilizing MICROBExpress and MICROBEnrich kits. High correlation of both Ribo-Zero and MICROBExpresse depleted gene expression profiles with total non-depleted RNA-seq data has been shown for all studied samples, indicating no systematic skewing of the studied pipelines. We have extensively evaluated the impact of the sampling strategy and library preparation steps on the metatranscriptomic profiles of the higher termite gut symbiotic bacteria. The presented methodological approach has great potential to enhance metatranscriptomic studies of the higher termite intestinal flora and to unravel novel carbohydrate-active enzymes.

  1. InstantLabs Listeria monocytogenes food safety kit. Performance tested method 051304.

    PubMed

    Sharma, Neil; Bambusch, Lauren; Le, Thu; Morey, Amit

    2014-01-01

    The InstantLabs Listeria monocytogenes Food Safety Kit was validated against the International Organization for Standardization (ISO) reference method 11290-1 for the detection of Listeria monocytogenes and other Listeria species. The matrixes (stainless steel, sealed concrete, ice cream, whole milk, cheddar cheese, raw shrimp, hot dogs, deli turkey, and lettuce) were inoculated with approximately 1 CFU/test portion of L. monocytogenes to generate fractional positives (5-15) in 20 inoculated samples. Enrichments were also fractionally inoculated with L. grayii for side-by-side testing of the Listeria Species Food Safety Kit. Stainless steel and sealed concrete samples were validated using 4 x 4" and 1 x 1 " test areas, respectively, and enriched in Buffered Listeria Enrichment Broth (BLEB) at 35 +/- 1degreesC for 22-28 h. All food samples were tested at 25 g and enriched in BLEB at 35 +/- 1 degreesC for 24-28 h. All samples were confirmed using the ISO reference method, regardless of initial screen result. The InstantLabs test method performed as well as or better than the reference method for the detection of L. monocytogenes on stainless steel and sealed concrete and in ice cream, whole milk, cheddar cheese, raw shrimp, hot dogs, deli turkey, and lettuce. Inclusivity and exclusivity testing revealed no false negatives and no false positives among the 50 L. monocytogenes serovars and 30 non-L. monocytogenes species examined. The method was shown to be robust when the enrichment times, volumes for DNA extraction, and heat block times were varied.

  2. Synthesis and application of mesoporous molecular sieve for miniaturized matrix solid-phase dispersion extraction of bioactive flavonoids from toothpaste, plant, and saliva.

    PubMed

    Cao, Wan; Cao, Jun; Ye, Li-Hong; Xu, Jing-Jing; Hu, Shuai-Shuai; Peng, Li-Qing

    2015-12-01

    This article describes the use of the mesoporous molecular sieve KIT-6 as a sorbent in miniaturized matrix solid-phase dispersion (MSPD) in combination with ultra-performance LC for the determination of bioactive flavonoids in toothpaste, Scutellariae Radix, and saliva. In this study, for the first time, KIT-6 was used as a sorbent material for this mode of extraction. Compared with common silica-based sorbents (C18 and activated silica gel), the proposed KIT-6 dispersant with a three-dimensional cubic Ia3d structure and highly ordered arrays of mesoporous channels exhibits excellent adsorption capability of the tested compounds. In addition, several experimental variables, such as the mass ratio of sample to dispersant, grinding time, and elution solvent, were optimized to maximize the extraction efficiency. The proposed analytical method is simple, fast, and entails low consumption of samples, dispersants and elution solvents, thereby meeting "green chemistry" requirements. Under the optimized conditions, the recoveries of three bioactive flavonoids obtained by analyzing the spiked samples were from 89.22 to 101.17%. Also, the LODs and LOQs for determining the analytes were in the range of 0.02-0.04 μg/mL and 0.07-0.13 μg/mL, respectively. Finally, the miniaturized matrix solid-phase dispersion method was successfully applied to the analysis of target solutes in real samples, and satisfactory results were obtained. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. [Performance evaluation of Abbott RealTime HBV Quantification Kit for HBV viral load by real-time PCR].

    PubMed

    Kim, Myeong Hee; Cha, Choong Hwan; An, Dongheui; Choi, Sung Eun; Oh, Heung Bum

    2008-04-01

    Hepatitis B virus (HBV) DNA quantification is necessary for starting and monitoring of antiviral therapy in patients with chronic hepatitis B. This study was intended to assess the clinical performance of Abbott RealTime HBV Quantification kit (Abbott Laboratories, USA). The performance was evaluated in terms of precision, linearity, detection sensitivity, cross-reactivity, and carry-over. A correlation with the Real-Q HBV Quantification kit (BioSewoom Inc., Korea) was also examined using serum samples from 64 patients diagnosed with chronic hepatitis B and underwent lamivudine therapy in Asan Medical Center. We verified the trueness of the system by comparing the outputs with the assigned values of the BBI panel (BBI Diagnostics, USA). Within-run and between-run coefficients of variation (CV) were 3.56-4.71% and 3.03-4.98%, respectively. Linearity was manifested ranging from 53 to 10(9)copies/mL and the detection sensitivity was verified to be 51 copies/mL. None of hepatitis C virus showed cross-reactivity. No cross-contamination occurred when negative and positive samples were alternatively placed in a row. It showed a good correlation with the Real-Q HBV (r(2)=0.9609) and the test results for the BBI panel were also well agreed to the assigned values (r(2)=0.9933). The performance of Abbott RealTime HBV Quantification kit was excellent; thus, it should be widely used in starting and monitoring of antiviral therapy in Korean patients with chronic hepatitis B.

  4. Immunodiagnosis of toxocarosis in humans: evaluation of a new enzyme-linked immunosorbent assay kit.

    PubMed Central

    Jacquier, P; Gottstein, B; Stingelin, Y; Eckert, J

    1991-01-01

    Excretory/secretory (E/S) antigen derived from second-stage larvae of Toxocara canis maintained in defined medium in vitro has been well established worldwide for the immunodiagnosis of human toxocarosis by enzyme-linked immunosorbent assay. Such an enzyme-linked immunosorbent assay, based on the detection of human anti-T. canis (E/S antigen) serum immunoglobulin G, has recently been commercialized by Biokema-Affinity Products (Crissier-Lausanne, Switzerland). This commercial test kit was evaluated with regard to its application in a routine diagnostic laboratory and the reliability of the results. Of 78 patients with suspected clinical toxocarosis, 71 had anti-T. canis antibodies (positive serological result) corresponding to a diagnostic sensitivity of 91%; 14% of serum samples (n = 199) from patients with protozoan or with helminthic infections also showed positive reactions mainly related to infections with Trichinella, Strongyloides, and Fasciola species. An epidemiological study with 1,000 serum samples from randomly selected healthy blood donors and children in Switzerland demonstrated a seroprevalence of 2.7%. The test kit under evaluation had an overall diagnostic sensitivity of 91% and a relative specificity of 86%, the latter being related to some protozoan and helminthic infections. Because of the scarcity of such infections, potential cross-reactivity does not play a major role under the conditions found in the middle part of Europe. In conclusion, the application of the test kit provided for use in this study can be recommended for routine diagnostic use. PMID:1774303

  5. Aviation Career Awareness

    ERIC Educational Resources Information Center

    Journal of Aerospace Education, 1976

    1976-01-01

    Describes a kit containing seven units, each designed to increase the elementary school student's awareness of aviation and career possibilities in aviation. Includes a sample section from one unit. (MLH)

  6. Population genetic analyses of the Powerplex(®) Fusion kit in a cosmopolitan sample of Chubut Province (Patagonia Argentina).

    PubMed

    Parolin, María Laura; Real, Luciano E; Martinazzo, Liza B; Basso, Néstor G

    2015-11-01

    Allele frequencies and forensic parameters for 22 autosomal STR loci and DYS391 locus included in the PowerPlex(®) Fusion System kit were estimated in a sample of 770 unrelated individuals from Chubut Province, southern Patagonia. No significant deviations from Hardy-Weinberg equilibrium were observed after Bonferroni's correction. The combined power of discrimination and the combined probability of exclusion were >0.999999 and 0.999984, respectively. Comparisons with other worldwide populations were performed. The MDS obtained show a close biological relation between Chubut and Chile. The estimated interethnic admixture supports a high Native American contribution (46%) in the population sample of Chubut. These results enlarge the Argentine databases of autosomal STR and would provide a valuable contribution for identification tests and population genetic studies. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Sensitivity or artifact? -- IQ Toxicity Test -- effluent values

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hayes, K.R.; Novotny, A.N.; Batista, N.

    1995-12-31

    Several complex effluents were DAPHNIA MAGNA IQ TOXICITY TESTED -- (1.25 hours) and conventionally tested with Daphnia magna (48 hours). In many samples the IQ Technology yielded low EC50 values while the 48 hour exposures yielded no acute toxicity. Possible explanations have been suggested for this occurrence such as: genotoxicity, mutagenicity, substrate interference, and enzyme satiation. To identify the causative agent(s) of this response a Toxicity Identification Evaluation was performed on one of the samples. To define the nature of the response, THE SOS-CHROMOTEST KIT and THE MUTA-CHROMOPLATE KIT were utilized to characterize genotoxicity and mutagenicity respectively. The sample didmore » not test positive for genotoxicity but tested positive for mutagenicity only after activation with S9 enzymes, suggesting the presence of promutagens. Additional work needs to be performed to correlate IQ TOXICITY TEST sensitivity with positive MUTA-CHROMOPLATE response.« less

  8. Evaluation of Direct PCR Amplification Using Various Swabs and Washing Reagents.

    PubMed

    Altshuler, Hallie; Roy, Reena

    2015-11-01

    DNA profiles were generated via direct amplification from blood and saliva samples deposited on various types of swab substrates. Each of the six non-FTA substrates used in this research was punched with a Harris 1.2 mm puncher. After 0.1 μL of blood or 0.5 μL saliva, samples were deposited on each of these punches, samples were pretreated with one of four buffers and washing reagents. Amplification was performed using direct and nondirect autosomal and Y-STR kits. Autosomal and Y-STR profiles were successfully generated from most of these substrates when pretreated with buffer or washing reagents. Concordant profiles were obtained within and between the six substrates, the six amplification kits, and all four reagents. The direct amplification of substrates which do not contain lysing agent would be beneficial to the forensic community as the procedure can be used on evidence samples commonly found at crime scenes. © 2015 American Academy of Forensic Sciences.

  9. School Board Policies on Leaves and Absences. Educational Policies Development Kit.

    ERIC Educational Resources Information Center

    National School Boards Association, Waterford, CT. Educational Policies Service.

    This report provides board policy samples and other policy resources on leaves and absences. The intent in providing policy samples is to encourage thinking in policy terms and to provide working papers that can be edited, modified, or adapted to meet local requirements. Topics covered in the samples include (1) sick leave, (2) maternity leave,…

  10. Evaluation of a rapid and inexpensive dipstick assay for the diagnosis of Plasmodium falciparum malaria.

    PubMed Central

    Mills, C. D.; Burgess, D. C.; Taylor, H. J.; Kain, K. C.

    1999-01-01

    Rapid, accurate and affordable methods are needed for the diagnosis of malaria. Reported here is an evaluation of a new immunochromatographic strip, the PATH Falciparum Malaria IC Strip, which is impregnated with an immobilized IgM monoclonal antibody that binds to the HRP-II antigen of Plasmodium falciparum. In contrast to other commercially available kits marketed for the rapid diagnosis of falciparum malaria, this kit should be affordable in the malaria-endemic world. Using microscopy and polymerase chain reaction (PCR)-based methods as reference standards, we compared two versions of the PATH test for the detection of P. falciparum infection in 200 febrile travellers. As determined by PCR and microscopy, 148 travellers had malaria, 50 of whom (33.8%) were infected with P. falciparum. Compared with PCR, the two versions of the PATH test had initial sensitivities of 90% and 88% and specificities of 97% and 96%, respectively, for the detection of falciparum malaria. When discrepant samples were retested blindly with a modified procedure (increased sample volume and longer washing step) the sensitivity and specificity of both kits improved to 96% and 99%, respectively. The two remaining false negatives occurred in samples with < 100 parasites per microliter of blood. The accuracy, simplicity and predicted low cost may make this test a useful diagnostic tool in malaria-endemic areas. PMID:10444878

  11. Comparative evaluation of rRNA depletion procedures for the improved analysis of bacterial biofilm and mixed pathogen culture transcriptomes

    PubMed Central

    Petrova, Olga E.; Garcia-Alcalde, Fernando; Zampaloni, Claudia; Sauer, Karin

    2017-01-01

    Global transcriptomic analysis via RNA-seq is often hampered by the high abundance of ribosomal (r)RNA in bacterial cells. To remove rRNA and enrich coding sequences, subtractive hybridization procedures have become the approach of choice prior to RNA-seq, with their efficiency varying in a manner dependent on sample type and composition. Yet, despite an increasing number of RNA-seq studies, comparative evaluation of bacterial rRNA depletion methods has remained limited. Moreover, no such study has utilized RNA derived from bacterial biofilms, which have potentially higher rRNA:mRNA ratios and higher rRNA carryover during RNA-seq analysis. Presently, we evaluated the efficiency of three subtractive hybridization-based kits in depleting rRNA from samples derived from biofilm, as well as planktonic cells of the opportunistic human pathogen Pseudomonas aeruginosa. Our results indicated different rRNA removal efficiency for the three procedures, with the Ribo-Zero kit yielding the highest degree of rRNA depletion, which translated into enhanced enrichment of non-rRNA transcripts and increased depth of RNA-seq coverage. The results indicated that, in addition to improving RNA-seq sensitivity, efficient rRNA removal enhanced detection of low abundance transcripts via qPCR. Finally, we demonstrate that the Ribo-Zero kit also exhibited the highest efficiency when P. aeruginosa/Staphylococcus aureus co-culture RNA samples were tested. PMID:28117413

  12. Clinical Evaluation of a Loop-Mediated Amplification Kit for Diagnosis of Imported Malaria

    PubMed Central

    Polley, Spencer D.; González, Iveth J.; Mohamed, Deqa; Daly, Rosemarie; Bowers, Kathy; Watson, Julie; Mewse, Emma; Armstrong, Margaret; Gray, Christen; Perkins, Mark D.; Bell, David; Kanda, Hidetoshi; Tomita, Norihiro; Kubota, Yutaka; Mori, Yasuyoshi; Chiodini, Peter L.; Sutherland, Colin J.

    2013-01-01

    Background. Diagnosis of malaria relies on parasite detection by microscopy or antigen detection; both fail to detect low-density infections. New tests providing rapid, sensitive diagnosis with minimal need for training would enhance both malaria diagnosis and malaria control activities. We determined the diagnostic accuracy of a new loop-mediated amplification (LAMP) kit in febrile returned travelers. Methods. The kit was evaluated in sequential blood samples from returned travelers sent for pathogen testing to a specialist parasitology laboratory. Microscopy was performed, and then malaria LAMP was performed using Plasmodium genus and Plasmodium falciparum–specific tests in parallel. Nested polymerase chain reaction (PCR) was performed on all samples as the reference standard. Primary outcome measures for diagnostic accuracy were sensitivity and specificity of LAMP results, compared with those of nested PCR. Results. A total of 705 samples were tested in the primary analysis. Sensitivity and specificity were 98.4% and 98.1%, respectively, for the LAMP P. falciparum primers and 97.0% and 99.2%, respectively, for the Plasmodium genus primers. Post hoc repeat PCR analysis of all 15 tests with discrepant results resolved 4 results in favor of LAMP, suggesting that the primary analysis had underestimated diagnostic accuracy. Conclusions. Malaria LAMP had a diagnostic accuracy similar to that of nested PCR, with a greatly reduced time to result, and was superior to expert microscopy. PMID:23633403

  13. Developmental validation of the PowerPlex(®) ESI 16 and PowerPlex(®) ESI 17 Systems: STR multiplexes for the new European standard.

    PubMed

    Tucker, Valerie C; Hopwood, Andrew J; Sprecher, Cynthia J; McLaren, Robert S; Rabbach, Dawn R; Ensenberger, Martin G; Thompson, Jonelle M; Storts, Douglas R

    2011-11-01

    In response to the ENFSI and EDNAP groups' call for new STR multiplexes for Europe, Promega(®) developed a suite of four new DNA profiling kits. This paper describes the developmental validation study performed on the PowerPlex(®) ESI 16 (European Standard Investigator 16) and the PowerPlex(®) ESI 17 Systems. The PowerPlex(®) ESI 16 System combines the 11 loci compatible with the UK National DNA Database(®), contained within the AmpFlSTR(®) SGM Plus(®) PCR Amplification Kit, with five additional loci: D2S441, D10S1248, D22S1045, D1S1656 and D12S391. The multiplex was designed to reduce the amplicon size of the loci found in the AmpFlSTR(®) SGM Plus(®) kit. This design facilitates increased robustness and amplification success for the loci used in the national DNA databases created in many countries, when analyzing degraded DNA samples. The PowerPlex(®) ESI 17 System amplifies the same loci as the PowerPlex(®) ESI 16 System, but with the addition of a primer pair for the SE33 locus. Tests were designed to address the developmental validation guidelines issued by the Scientific Working Group on DNA Analysis Methods (SWGDAM), and those of the DNA Advisory Board (DAB). Samples processed include DNA mixtures, PCR reactions spiked with inhibitors, a sensitivity series, and 306 United Kingdom donor samples to determine concordance with data generated with the AmpFlSTR(®) SGM Plus(®) kit. Allele frequencies from 242 white Caucasian samples collected in the United Kingdom are also presented. The PowerPlex(®) ESI 16 and ESI 17 Systems are robust and sensitive tools, suitable for the analysis of forensic DNA samples. Full profiles were routinely observed with 62.5pg of a fully heterozygous single source DNA template. This high level of sensitivity was found to impact on mixture analyses, where 54-86% of unique minor contributor alleles were routinely observed in a 1:19 mixture ratio. Improved sensitivity combined with the robustness afforded by smaller amplicons has substantially improved the quantity of data obtained from degraded samples, and the improved chemistry confers exceptional tolerance to high levels of laboratory prepared inhibitors. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  14. Haplotype data for 23 Y-chromosome markers in four U.S. population groups.

    PubMed

    Coble, Michael D; Hill, Carolyn R; Butler, John M

    2013-05-01

    The PowerPlex Y23 kit contains 23 Y-chromosomal loci including all 17 of the markers in the Yfiler Y-STR kit plus six additional markers: DYS481, DYS533, DYS549, DYS570, DYS576, and DYS643. We have typed 1032 unrelated population samples from four self-declared US groups: African Americans, Asians, Hispanics, and Western European Caucasians. An analysis of the population genetic parameters and the improvement of adding additional Y-STR markers to the dataset are described. Published by Elsevier Ireland Ltd.

  15. Commander De Winne poses for a photo during Air Sampling

    NASA Image and Video Library

    2009-11-11

    ISS021-E-024700 (11 Nov. 2009) --- European Space Agency astronaut Frank De Winne, Expedition 21 commander, uses the Microbial Air Sampler kit (floating freely near De Winne) to obtain microbiology (bacterial & fungal) air samples in the Kibo laboratory of the International Space Station.

  16. Evaluation of DNA extraction methods for the analysis of microbial community in biological activated carbon.

    PubMed

    Zheng, Lu; Gao, Naiyun; Deng, Yang

    2012-01-01

    It is difficult to isolate DNA from biological activated carbon (BAC) samples used in water treatment plants, owing to the scarcity of microorganisms in BAC samples. The aim of this study was to identify DNA extraction methods suitable for a long-term, comprehensive ecological analysis of BAC microbial communities. To identify a procedure that can produce high molecular weight DNA, maximizes detectable diversity and is relatively free from contaminants, the microwave extraction method, the cetyltrimethylammonium bromide (CTAB) extraction method, a commercial DNA extraction kit, and the ultrasonic extraction method were used for the extraction of DNA from BAC samples. Spectrophotometry, agarose gel electrophoresis and polymerase chain reaction (PCR)-restriction fragment length polymorphisms (RFLP) analysis were conducted to compare the yield and quality of DNA obtained using these methods. The results showed that the CTAB method produce the highest yield and genetic diversity of DNA from BAC samples, but DNA purity was slightly less than that obtained with the DNA extraction-kit method. This study provides a theoretical basis for establishing and selecting DNA extraction methods for BAC samples.

  17. Detection of oral HPV infection - Comparison of two different specimen collection methods and two HPV detection methods.

    PubMed

    de Souza, Marjorie M A; Hartel, Gunter; Whiteman, David C; Antonsson, Annika

    2018-04-01

    Very little is known about the natural history of oral HPV infection. Several different methods exist to collect oral specimens and detect HPV, but their respective performance characteristics are unknown. We compared two different methods for oral specimen collection (oral saline rinse and commercial saliva kit) from 96 individuals and then analyzed the samples for HPV by two different PCR detection methods (single GP5+/6+ PCR and nested MY09/11 and GP5+/6+ PCR). For the oral rinse samples, the oral HPV prevalence was 10.4% (GP+ PCR; 10% repeatability) vs 11.5% (nested PCR method; 100% repeatability). For the commercial saliva kit samples, the prevalences were 3.1% vs 16.7% with the GP+ PCR vs the nested PCR method (repeatability 100% for both detection methods). Overall the agreement was fair or poor between samples and methods (kappa 0.06-0.36). Standardizing methods of oral sample collection and HPV detection would ensure comparability between future oral HPV studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Correlates of requesting home HIV self-testing kits on online social networks among African-American and Latino men who have sex with men.

    PubMed

    Chiu, ChingChe J; Young, Sean D

    2016-01-01

    High levels of HIV stigma are one of the main difficulties in engaging African-American and Latino men who have sex with men (MSM) in HIV testing. The availability of home HIV test and the possibility of self-testing in private may improve uptake and counteract stigma. This paper sought to determine the correlates of requesting home HIV test kits among a sample of MSM social media users. The odds of participants requesting a test kit were significantly associated with using social networks to seek sexual partners (aOR: 2.47, 95% CI: 1.07-6.06) and thinking it is easier to use social networks for seeking sexual partners (1.87, 1.2-3.12), uncertain HIV status (4.29, 1.37-14.4), and having sex under the influence of alcohol (2.46, 1.06-5.77). Participants who had not been tested for more than 6 months were more likely to request a test kit than those who were tested in the past 6 months (2.53, 1.02-6.37). Participants who frequently talked to others about having sex with men online were less likely to request a test kit (0.73, 0.56-0.92). By reaching people over social media and offering them access to test kits, we were able to reach at-risk individuals who were uncertain about their HIV status and had not been regularly tested. The findings of the study will help to inform future HIV testing interventions.

  19. Evaluation of the SD BIOLINE Dengue Duo rapid test in the course of acute and convalescent dengue infections in a Mexican endemic region.

    PubMed

    Sánchez-Vargas, Luis A; Sánchez-Marce, Elvis E; Vivanco-Cid, Héctor

    2014-04-01

    In this study, we evaluated the performance of a rapid test, the SD BIOLINE Dengue Duo (SD BDD) kit, with a panel of serum samples from 310 Mexican patients with diagnosis of dengue infection previously confirmed by reference enzyme-linked immunosorbent assay tests. Eighty-seven negative samples from other febrile illnesses were included as controls. The SD BDD showed an overall sensitivity of 90.65% and specificity of 89.66%. No statistically significant differences were found in the sensitivity of the SD BDD kit compared between primary or secondary infections (87.05% versus 93.57%, respectively, P = 0.0761) and dengue fever or dengue hemorrhagic fever cases (90.77% versus 89.74%, respectively, P = 0.7716). However, a higher sensitivity in the acute phase of dengue infection was found compared with the convalescent phase (93.03% versus 81.82%, respectively, P = 0.0089). These results indicate that the SD BDD kit is a useful tool to diagnose dengue infections, both in primary or secondary infections and mainly during the acute phase. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Direct Detection and Genotyping of Klebsiella pneumoniae Carbapenemases from Urine by Use of a New DNA Microarray Test

    PubMed Central

    Peter, Harald; Berggrav, Kathrine; Thomas, Peter; Pfeifer, Yvonne; Witte, Wolfgang; Templeton, Kate

    2012-01-01

    Klebsiella pneumoniae carbapenemases (KPCs) are considered a serious threat to antibiotic therapy, as they confer resistance to carbapenems, which are used to treat extended-spectrum beta-lactamase (ESBL)-producing bacteria. Here, we describe the development and evaluation of a DNA microarray for the detection and genotyping of KPC genes (blaKPC) within a 5-h period. To test the whole assay procedure (DNA extraction plus a DNA microarray assay) directly from clinical specimens, we compared two commercial DNA extraction kits (the QIAprep Spin miniprep kit [Qiagen] and the urine bacterial DNA isolation kit [Norgen]) for the direct DNA extraction from urine samples (dilution series spiked in human urine). Reliable single nucleotide polymorphism (SNP) typing was demonstrated using 1 × 105 CFU/ml urine for Escherichia coli (Qiagen and Norgen) and 80 CFU/ml urine, on average, for K. pneumoniae (Norgen). This study presents, for the first time, the combination of a new KPC microarray with commercial sample preparation for detecting and genotyping microbial pathogens directly from clinical specimens; this paves the way toward tests providing epidemiological and diagnostic data, enabling better antimicrobial stewardship. PMID:23035190

  1. Recognition of Y Fragment Deletion by Genotyping Graphs after Amplified by PowerPlex® 21 Detection Kit.

    PubMed

    Wang, S C; Ding, M M; Wei, X L; Zhang, T; Yao, F

    2016-06-01

    To recognize the possibility of Y fragment deletion of Amelogenin gene intuitively and simply according to the genotyping graphs. By calculating the ratio of total peak height of genotyping graphs, the statistics of equilibrium distribution between Amelogenin and D3S1358 loci, Amelogenin X-gene and Amelogenin Y-gene, and different alleles of D3S1358 loci from 1 968 individuals was analyzed after amplified by PowerPlex ® 21 detection kit. Sum of peak height of Amelogenin X allele was not less than 60% that of D3S1358 loci alleles in 90.8% female samples, and sum of peak height of Amelogenin X allele was not higher than 70% that of D3S1358 loci alleles in 94.9% male samples. The result of genotyping after amplified by PowerPlex ® 21 detection kit shows that the possibility of Y fragment deletion should be considered when only Amelogenin X-gene of Amelogenin is detected and the peak height of Amelogenin X-gene is not higher than 70% of the total peak height of D3S1358 loci. Copyright© by the Editorial Department of Journal of Forensic Medicine

  2. [Analysis of the dilution deviation in CA19-9 measurement].

    PubMed

    Hanada, Hiroyuki; Takeoka, Keiko; Nomura, Tomoko; Moriyama, Takanori; Kanakura, Yuzuru

    2005-04-01

    CA19-9 widely used as a tumor marker of the pancreas and a bile duct. There are a number of reports which describes the measured value discrepancies between RIA and non-RIA kits. RIA results also have shown lack of the linearity over 70 U/ml when the samples are diluted. The pH condition at assay reaction for RIA had been suggested as the major reason, it has been denied by the results from the same pH condition at assay reaction used by COBAS CORE CA19-9 EIA II. On the other hand, the lack of RIA antibody titer is indicated for the discordant results by changing the sample volume to reagent volume ratio in the reaction. Our further investigation also indicates that the specific Lewis blood type, i.e. Le (a-b+), shows the linearity issues by RIA. The discrepancies are not caused by the reaction pH, but the amount of the antibody used in the RIA kit is closely associated. Considering the CA19-9 antibody nature used in RIA kit, which covers broad molecular range, users need to pay more attention to setting up each laboratory's measuring range.

  3. Performance of the Extravehicular Mobility Unit (EMU): Airlock Coolant Loop Recovery (A/L CLR) Hardware - Phase II

    NASA Technical Reports Server (NTRS)

    Steele, John; Rector, tony; Gazda, Daniel; Lewis, John

    2009-01-01

    An EMU water processing kit (Airlock Coolant Loop Recovery A/L CLR) was developed as a corrective action to Extravehicular Mobility Unit (EMU) coolant flow disruptions experienced on the International Space Station (ISS) in May of 2004 and thereafter. Conservative schedules for A/L CLR use and component life were initially developed and implemented based on prior analysis results and analytical modeling. The examination of postflight samples and EMU hardware in November of 2006 indicated that the A/L CLR kits were functioning well and had excess capacity that would allow a relaxation of the initially conservative schedules of use and component life. A relaxed use schedule and list of component lives was implemented thereafter. Since the adoption of the relaxed A/L CLR schedules of use and component lives, several A/L CLR kit components, transport loop water samples and sensitive EMU transport loop components have been examined to gage the impact of the relaxed requirements. The intent of this paper is to summarize the findings of that evaluation, and to outline updated schedules for A/L CLR use and component life.

  4. Technology assessment and strategy for development of a Rapid Field Water Microbiology Test Kit. Technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Preston, D.R.; Schaub, S.A.

    1991-09-01

    A literature and market search of existing technology for the detection, identification, and quantification of microorganisms in water was conducted. Based upon the availability of technologies and their configurations, an assessment of the appropriate strategies to pursue for the near and long term development plans in development of the Rapid Field Bacteriology Test Kit was performed. Near term technologies to improve the Army's capability to detect microorganisms would appear to be essentially improvements in versatility and measurement of coliform indicator organisms. New chromogenic and fluorogenic indicator substances associated with new substrates appear to be best suited for test kit developmentmore » either for quantitative membrane filter tests or presence/absence and multiple fermentation tests. Test times, incubator requirements, and operator involvement appear to be similar to older technologies. Long term development would appear to favor such technologies as genetic probes with amplification of the hydridized nucleic acid materials of positive samples, and some immunological based systems such as enzyme linked, immuno-sorbent assays. In both cases, the major problems would appear to be sample preparation and development of signal strengths from the reactions which would allow the user to see results in 1 hour.« less

  5. Expression of c-kit receptor in human cholangiocarcinoma and in vivo treatment with imatinib mesilate in chimeric mice

    PubMed Central

    Kamenz, Thomas; Caca, Karel; Blüthner, Thilo; Tannapfel, Andrea; Mössner, Joachim; Wiedmann, Marcus

    2006-01-01

    AIM: To investigate the c-kit expression in biliary tract cancer cell lines and histological sections from patients with extrahepatic cholangiocarcinoma (CC) and to evaluate the efficacy of in vitro and in vitro treatment with imatinib mesilate. METHODS: The protein expression of c-kit in the human biliary tract cancer cell lines Mz-ChA-2 and EGI-1 and histological sections from 19 patients with extrahepatic CC was assessed by immunoblotting, immunocytochemistry, and immunohistochemistry. The anti-proliferative effect of imatinib mesilate on biliary tract cancer cell lines Mz-ChA-2 and EGI-1 was studied in vitro by automated cell counting. In addition, immunodeficient NMRI mice (TaconicTM) were subcutaneously injected with 5 x 106 cells of cell lines MzChA-2 and EGI-1. After having reached a tumour volume of 200 mm3, daily treatment was started intraperitoneally with imatinib mesilate at a dose of 50 mg/kg or normal saline (NS). Tumor volume was calculated with a Vernier caliper. After 14 d, mice were sacrificed with tumors excised and tumor mass determined. RESULTS: Immunoblotting revealed presence of c-kit in Mz-ChA-2 and absence in EGI-1 cells. Immunocytochemistry with c-kit antibodies displayed a cytoplasmatic and membraneous localization of receptor protein in Mz-ChA-2 cells and absence of c-kit in EGI-1 cells. c-kit was expressed in 7 of 19 (37%) extrahepatic human CC tissue samples, 2 showed a moderate and 5 a rather weak immunostaining. Imatinib mesilate at a low concentration of 5 µmol/L caused a significant growth inhibition in the c-kit positive cell line Mz-ChA-2 (31%), but not in the c-kit negative cell line EGI-1 (0%) (P < 0.05). Imatinib mesilate at an intermediate concentration of 10 µmol/L inhibited cellular growth of both cell lines (51% vs 57%). Imatinib mesilate at a higher concentration of 20 µmol/L seemed to have a general toxic effect on both cell lines. The IC50 values were 9.7 µmol/L and 11 µmol/L, respectively. After 14 d of in vitro treatment with imatinib mesilate, using the chimeric mouse model, c-kit positive Mz-ChA-2 tumors had a significantly reduced volume and mass as compared to NS treatment (P < 0.05). In contrast to that, treatment of mice bearing c-kit negative EGI-1 tumors did not result in any change of tumor volume and mass as compared to NS treatment. CONCLUSION: c-kit expression is detectable at a moderate to low protein level in biliary tract cancer. Imatinib mesilate exerts marked effects on tumor growth in vitro and in vitro dependent on the level of c-kit expression. PMID:16570351

  6. A tubular-coring device for use in biogeochemical sampling of succulent and pulpy plants

    USGS Publications Warehouse

    Campbell, W.L.

    1986-01-01

    A hand-operated, tubular-coring device developed for use in biogeochemical sampling of succulent and pulpy plants is described. The sampler weighs about 500 g (1.1 lb); and if 25 ?? 175 mm (1 ?? 7 in) screw-top test tubes are used as sample containers, the complete sampling equipment kit is easily portable, having both moderate bulk and weight. ?? 1986.

  7. Internal validation of two new retrotransposons-based kits (InnoQuant® HY and InnoTyper® 21) at a forensic lab.

    PubMed

    Martins, Cátia; Ferreira, Paulo Miguel; Carvalho, Raquel; Costa, Sandra Cristina; Farinha, Carlos; Azevedo, Luísa; Amorim, António; Oliveira, Manuela

    2018-02-01

    Obtaining a genetic profile from pieces of evidence collected at a crime scene is the primary objective of forensic laboratories. New procedures, methods, kits, software or equipment must be carefully evaluated and validated before its implementation. The constant development of new methodologies for DNA testing leads to a steady process of validation, which consists of demonstrating that the technology is robust, reproducible, and reliable throughout a defined range of conditions. The present work aims to internally validate two new retrotransposon-based kits (InnoQuant ® HY and InnoTyper ® 21), under the working conditions of the Laboratório de Polícia Científica da Polícia Judiciária (LPC-PJ). For the internal validation of InnoQuant ® HY and InnoTyper ® 21 sensitivity, repeatability, reproducibility, and mixture tests and a concordance study between these new kits and those currently in use at LPC-PJ (Quantifiler ® Duo and GlobalFiler™) were performed. The results obtained for sensitivity, repeatability, and reproducibility tests demonstrated that both InnoQuant ® HY and InnoTyper ® 21 are robust, reproducible, and reliable. The results of the concordance studies demonstrate that InnoQuant ® HY produced quantification results in nearly 29% more than Quantifiler ® Duo (indicating that this new kit is more effective in challenging samples), while the differences observed between InnoTyper ® 21 and GlobalFiler™ are not significant. Therefore, the utility of InnoTyper ® 21 has been proven, especially by the successful amplification of a greater number of complete genetic profiles (27 vs. 21). The results herein presented allowed the internal validation of both InnoQuant ® HY and InnoTyper ® 21, and their implementation in the LPC-PJ laboratory routine for the treatment of challenging samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. DNA typing for personal identification of urine after long-term preservation for testing in doping control.

    PubMed

    Aoki, Kimiko; Tanaka, Hiroyuki; Ueki, Makoto

    2017-08-01

    When the tampering of a urine sample is suspected in doping control, personal identification of the sample needs to be determined by short tandem repeat (STR) analysis using DNA. We established a method for extracting DNA from urine samples stored at -20 °C without using any additives or procedures, which is consistent with how samples are required to be managed for doping control. The method, using the Puregene® Blood Core kit followed by NucleoSpin® gDNA Clean-up or NucleoSpin® gDNA Clean-up XS kit, does not need any special instrument and can provide a purified extract with high-quality DNA from up to 40 mL of urine suitable for STR analysis using an AmpFlSTR® Identifiler® PCR amplification kit. Storing urine at -20 °C is detrimental to the stability of DNA. The DNA concentration of preserved urine could not be predicted by specific gravity or creatinine level at the time of urine collection. The DNA concentration of a purified extract (10 μL) was required to be >0.06 ng/μL to ensure a successful STR analysis. Thus, the required extraction volumes of urine preserved for 3-7 years at -20 °C were estimated to be 30 mL and 20 mL to succeed in at least 86% of men and 91% of women, respectively. Considering the long half-life of DNA during long-term preservation, our extraction method is applicable to urine samples stored even for 10 years, which is currently the storage duration allowed (increased from 8 years) before re-examination in doping control. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Multicolor-based discrimination of 21 short tandem repeats and amelogenin using four fluorescent universal primers.

    PubMed

    Asari, Masaru; Okuda, Katsuhiro; Hoshina, Chisato; Omura, Tomohiro; Tasaki, Yoshikazu; Shiono, Hiroshi; Matsubara, Kazuo; Shimizu, Keiko

    2016-02-01

    The aim of this study was to develop a cost-effective genotyping method using high-quality DNA for human identification. A total of 21 short tandem repeats (STRs) and amelogenin were selected, and fluorescent fragments at 22 loci were simultaneously amplified in a single-tube reaction using locus-specific primers with 24-base universal tails and four fluorescent universal primers. Several nucleotide substitutions in universal tails and fluorescent universal primers enabled the detection of specific fluorescent fragments from the 22 loci. Multiplex polymerase chain reaction (PCR) produced intense FAM-, VIC-, NED-, and PET-labeled fragments ranging from 90 to 400 bp, and these fragments were discriminated using standard capillary electrophoretic analysis. The selected 22 loci were also analyzed using two commercial kits (the AmpFLSTR Identifiler Kit and the PowerPlex ESX 17 System), and results for two loci (D19S433 and D16S539) were discordant between these kits due to mutations at the primer binding sites. All genotypes from the 100 samples were determined using 2.5 ng of DNA by our method, and the expected alleles were completely recovered. Multiplex 22-locus genotyping using four fluorescent universal primers effectively reduces the costs to less than 20% of genotyping using commercial kits, and our method would be useful to detect silent alleles from commercial kit analysis. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Evaluation of wondfo rapid diagnostic kit (Pf-HRP2/PAN-pLDH) for diagnosis of malaria by using nano-gold immunochromatographic assay.

    PubMed

    Wu, Junlin; Peng, Yunping; Liu, Xiaoyun; Li, Wenmei; Tang, Shixing

    2014-06-01

    Prompt and accurate diagnosis is necessary to start adequate treatment for different affecting species including P. falciparum and P. vivax. Here we described the Wondfo Rapid diagnostic Kit (Pf-HRP2/PAN-pLDH) for the detection of P. falciparum and pan-plasmodium in patient specimen by using a nano-gold immunochromatographic assay. Our rapid assay adapted nano-gold labeling techniques and the monoclonal antibodies (mAbs) against both histidine rich protein-2 (Pf HRP-2) of P. falciparum and pan plasmodium-specific pLDH (pan pLDH). The established two-antibody sandwich immunochromatographic assay could detect P. falciparum and pan-plasmodium. The sensitivity and specificity of Wondfo rapid diagnostic kit were determined by comparing with the "gold standard" of microscopic examination of blood smears. In this study1023 blood samples were collected from outpatient clinics in China and Burma, and detected by both Wondfo kit and microscopic examination. The detection sensitivity and specificity of Wondfo rapid diagnostic kit were 96.46% and 99.67% for P. falciparum (HRP2), 95.03% and 99.24% for pLDH, 96.83% and 99.74% for non-falciparum species, 96.70% and 99.74% for P. vivax, respectively. These results indicate that Wondfo rapid diagnostic assay may be useful for detecting P. falciparum and non-P. falciparum (especially P.v.) in patient specimen.

  11. EVALUATION OF SPERM CHROMATIN STRUCTURE ASSAY (SCSA REGISTERED TRADEMARK) IN HUMAN SPERM AFTER SIMULATED OVERNIGHT SHIPMENT

    EPA Science Inventory

    Home semen collection kits allow men to collect a sample at their convenience and send it via overnight mail to the laboratory. Benefits of this approach include facilitated sample collection from different geographic locations, minimized variability through analysis by a central...

  12. A Multimedia Publishing Center from Scratch (and Scavenge).

    ERIC Educational Resources Information Center

    D'Ignazio, Fred

    1995-01-01

    Provides guidance for turning the library media center into a place where students can use multimedia tools for research, authoring, and publishing. Sidebars include: a multimedia club sample student contract, a component list for a multimedia workstation starter kit, a checklist for planning and assembling mini-centers, and a sample multimedia…

  13. 46 CFR 160.054-7 - Procedure for approval.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the first-aid kit. At the time of selection of the pre-approval sample, the manufacturer shall furnish... forwarding to the Commandant. (b) Pre-approval sample. After the first drawings have been examined and found..., prepaid by the manufacturer, to the Commandant for the necessary conditioning and tests in accordance with...

  14. INTERIM REPORT ON THE EVOLUTION AND ...

    EPA Pesticide Factsheets

    A demonstration of screening technologies for determining the presence of dioxin and dioxin-like compounds in soil and sediment was conducted under the U.S. Environmental Protection Agency's(EPA's) Superfund Innovative Technology Evaluation Program in Saginaw, Michigan in 2004. The objectives of the demonstration included evaluating each participating technology's accuracy, precision, sensitivity, sample throughput, tendency for matrix effects, and cost. The test also included an assessment of how well the technology's results compared to those generated by established laboratory methods using high-resolution mass spectrometry (HRMS). The demonstration objectives were accomplished by evaluating the results generated by each technology from 209 soil, sediment, and extract samples. The test samples included performance evaluation (PE) samples (i.e., contaminant concentrations were certified or the samples were spiked with known contaminants) and environmental samples collected from 10 different sampling locations. The PE and environmental samples were distributed to the technology developers in blind, random order. One of the participants in the original SITE demonstration was Hybrizyme Corporation, which demonstrated the use of the AhRC PCR Kit. The AhRC PCR Kit was a technology that reported the concentration of aryl hydrocarbon receptor (AhR) binding compounds in a sample, with units reported as Ah Receptor Binding Units (AhRBU). At the time of the original dem

  15. Sero-prevalence of bovine Johne's disease in buffaloes and cattle population of North India using indigenous ELISA kit based on native Mycobacterium avium subspecies paratuberculosis 'Bison type' genotype of goat origin.

    PubMed

    Singh, S V; Singh, A V; Singh, R; Sharma, S; Shukla, N; Misra, S; Singh, P K; Sohal, J S; Kumar, H; Patil, P K; Misra, P; Sandhu, K S

    2008-09-01

    Present pilot study is the first attempt in the country to estimate sero-prevalence of Bovine Johne's disease (BJD) by screening cattle and buffaloes representing large population belonging to farmer's and farm herds in the home tracts (Uttar Pradesh (UP) and Punjab) of Hariana cattle and Murrah buffaloes in North India. Indigenous and in-house plate ELISA kit (using protoplasmic antigen from native Mycobacterium avium subsp. paratuberculosis 'Bison type' strain of goat origin), originally developed for goats and sheep was standardized in bovines and used for screening. For this study, 33 villages of south and west UP were randomly selected and surveyed from 2001 to 2003. There were 7943 farmer's families having 38,251 livestock, including cattle, buffaloes, goats and sheep (per family 4.8% livestock). Numerically, buffaloes and cattle were 54.7% and 22.1%, respectively. Serum samples were collected from 726 animals (4.2% of 16, 981 livestock with 4375 farmer's families) located in 33 randomly surveyed villages. Serum samples (699), submitted to Epidemiology Department of Veterinary College (Punjab Agricultural University, Ludhiana), in the year 2004 by farmer's and organized farm herds (Buffaloes, 372, Cattle, 327), were screened by this ELISA kit. Soluble protoplasmic antigen was prepared from Map (S 5) 'Bison type' strain isolated from a terminally sick goat with Johne's disease. Of the total 1425 bovine (Buffaloes and cattle) serum samples screened using indigenous ELISA kit, sero-prevalence of Johne's disease was 29.0% (28.6% in buffalo and 29.8% in cattle) in Northern India. State-wise sero-prevalence was 31.9% and 23.3% in UP and Punjab, respectively. In UP, of the 601 randomly sampled buffaloes, sero-prevalence was 40.3% (16.6% in young and 40.9% adults) and 25.5% (10.5% in young and 26.3% adults) in south and west UP, respectively. Of the 125 cattle screened, sero-prevalence was 42.6% (nil in young and 44.4% adults) and 30.0% (nil in young and 30.6% adults) in south and west UP, respectively. Of the 699 serum samples screened from Ludhiana, Punjab, sero-prevalence of BJD was 23.0%. Sero-prevalence was 23.3% (12.1% in young and 24.4% in adults) and 26.9% (27.2% in young and 26.8% in adults) in buffaloes and cattle, respectively. High prevalence of BJD in buffaloes in native tract of Murrah breed, and Hariana breed of cattle correlated with poor per-animal productivity and BJD may be the major cause. Indigenous ELISA kit was rapid, economic and sensitive test for large-scale screening of buffaloes and cattle population against incurable BJD.

  16. [Automated RNA amplification for the rapid identification of Mycobacterium tuberculosis complex in respiratory specimens].

    PubMed

    Drouillon, V; Houriez, F; Buze, M; Lagrange, P; Herrmann, J-L

    2006-01-01

    Rapid and sensitive detection of Mycobacterium tuberculosis complex (MTB) directly on clinical respiratory specimens is essential for a correct management of patients suspected of tuberculosis. For this purpose PCR-based kits are available to detect MTB in respiratory specimen but most of them need at least 4 hours to be completed. New methods, based on TRC method (TRC: Transcription Reverse transcription Concerted--TRCRapid M. Tuberculosis--Tosoh Bioscience, Tokyo, Japon) and dedicated monitor have been developed. A new kit (TRC Rapid M. tuberculosis and Real-time monitor TRCRapid-160, Tosoh Corporation, Japan) enabling one step amplification and real-time detection of MTB 16S rRNA by a combination of intercalative dye oxazole yellow-linked DNA probe and isothermal RNA amplification directly on respiratory specimens has been tested in our laboratory. 319 respiratory specimens were tested in this preliminary study and results were compared to smear and culture. Fourteen had a positive culture for MTB. Among theses samples, smear was positive in 11 cases (78.6%) and TRC process was positive in 8 cases (57.1%). Overall sensitivity of TRC compared to smear positive samples is 73%. Theses first results demonstrated that a rapid identification of MTB was possible (less than 2 processing hours for 14 specimens and about 1 hour for 1 specimen) in most cases of smear positive samples using ready to use reagents for real time detection of MTB rRNA in clinical samples. New pretreatment and extraction reagents kits to increase the stability of the sputum RNA and the extraction efficiency are now tested in our laboratory.

  17. Evaluation of the performance of the IQ-Check kits and the USDA Microbiology Laboratory Guidebook methods for detection of Shiga toxin-producing Escherichia coli (STEC) and STEC and Salmonella simultaneously in ground beef.

    PubMed

    Baranzoni, G M; Fratamico, P M; Boccia, F; Bagi, L K; Kim, G-H; Anastasio, A; Pepe, T

    2017-03-01

    To evaluate the performance of the IQ-Check kits and the USDA Microbiology Laboratory Guidebook (MLG) methods for detection of the top seven Shiga toxin-producing Escherichia coli (STEC) (O157:H7, O26, O45, O103, O111, O121 and O145) in ground beef and both STEC and Salmonella in co-inoculated samples. Ground beef samples inoculated with ~10 CFU of STEC or both STEC and Salmonella Typhimurium were stored at 4°C for 72 h, followed by screening with the IQ-Check and BAX System kit (MLG) methods that employ different enrichment media. STEC and S. Typhimurium were detected after 12 and 18 h and their presence was confirmed by colony isolation. Both methods were able to detect STEC in ground beef after 12 h of enrichment in samples inoculated with low levels of the pathogen. STEC and S. Typhimurium can be detected and isolated in co-inoculated ground beef samples. The IQ-Check methods are comparable to the MLG methods for detection of STEC and simultaneous detection of STEC and S. Typhimurium in seeded ground beef after a short enrichment time, thus the IQ-Check method can be useful for the food industry for rapid detection of these pathogens. Published 2016. This article has been contributed to by US Government employees and their work is in the public domain in the USA.

  18. DNA Extraction from Protozoan Oocysts/Cysts in Feces for Diagnostic PCR

    PubMed Central

    2014-01-01

    PCR detection of intestinal protozoa is often restrained by a poor DNA recovery or by inhibitors present in feces. The need for an extraction protocol that can overcome these obstacles is therefore clear. QIAamp® DNA Stool Mini Kit (Qiagen) was evaluated for its ability to recover DNA from oocysts/cysts directly from feces. Twenty-five Giardia-positive, 15 Cryptosporidium-positive, 15 Entamoeba histolytica-positive, and 45 protozoa-free samples were processed as control by microscopy and immunoassay tests. DNA extracts were amplified using 3 sets of published primers. Following the manufacturer's protocol, the kit showed sensitivity and specificity of 100% towards Giardia and Entamoeba. However, for Cryptosporidium, the sensitivity and specificity were 60% (9/15) and 100%, respectively. A series of optimization experiments involving various steps of the kit's protocol were conducted using Cryptosporidium-positive samples. The best DNA recoveries were gained by raising the lysis temperature to the boiling point for 10 min and the incubation time of the InhibitEX tablet to 5 min. Also, using a pre-cooled ethanol for nucleic acid precipitation and small elution volume (50-100 µl) were valuable. The sensitivity of the amended protocol to Cryptosporidium was raised to 100%. Cryptosporidium DNA was successfully amplified by either the first or the second primer set. When applied on parasite-free feces spiked with variable oocysts/cysts counts, ≈ 2 oocysts/cysts were theoretically enough for detection by PCR. To conclude, the Qiagen kit with the amended protocol was proved to be suitable for protozoan DNA extraction directly from feces and support PCR diagnosis. PMID:25031466

  19. DNA extraction from protozoan oocysts/cysts in feces for diagnostic PCR.

    PubMed

    Hawash, Yousry

    2014-06-01

    PCR detection of intestinal protozoa is often restrained by a poor DNA recovery or by inhibitors present in feces. The need for an extraction protocol that can overcome these obstacles is therefore clear. QIAamp® DNA Stool Mini Kit (Qiagen) was evaluated for its ability to recover DNA from oocysts/cysts directly from feces. Twenty-five Giardia-positive, 15 Cryptosporidium-positive, 15 Entamoeba histolytica-positive, and 45 protozoa-free samples were processed as control by microscopy and immunoassay tests. DNA extracts were amplified using 3 sets of published primers. Following the manufacturer's protocol, the kit showed sensitivity and specificity of 100% towards Giardia and Entamoeba. However, for Cryptosporidium, the sensitivity and specificity were 60% (9/15) and 100%, respectively. A series of optimization experiments involving various steps of the kit's protocol were conducted using Cryptosporidium-positive samples. The best DNA recoveries were gained by raising the lysis temperature to the boiling point for 10 min and the incubation time of the InhibitEX tablet to 5 min. Also, using a pre-cooled ethanol for nucleic acid precipitation and small elution volume (50-100 µl) were valuable. The sensitivity of the amended protocol to Cryptosporidium was raised to 100%. Cryptosporidium DNA was successfully amplified by either the first or the second primer set. When applied on parasite-free feces spiked with variable oocysts/cysts counts, ≈ 2 oocysts/cysts were theoretically enough for detection by PCR. To conclude, the Qiagen kit with the amended protocol was proved to be suitable for protozoan DNA extraction directly from feces and support PCR diagnosis.

  20. [Comparison of commercial HIV-1 viral load tests by using proficiency test results in China, 2013- 2015].

    PubMed

    Zhang, L; Jin, C; Jiang, Z; Tang, T; Jiang, Y; Pan, P L

    2017-09-10

    Objective: To compare the bio-equivalence among commercial HIV-1 viral load tests, including EasyQ HIV-1 v2.0 (EasyQ) from bioMerieux NucliSens of France; VERSANT HIV-1 RNA 3.0 assay (bDNA) from Siemens Healthcare Diagnostics of USA; COBAS AmpliPrep/COBAS TaqMan HIV-1 test (Taqman) from Roche Molecular Diagnosis of USA; Abbott Real Time HIV-1 Kit (M2000) from Abbott Molecular of USA and two domestic HIV-1 viral load test kits (domestic kit) from DaAn Gene Company of Sun Yat-Sen University and Liaoning Bio-Pharmaceutical company of Northeast pharmaceutical group, by using proficiency test results in China from 2013 to 2015. Methods: A total of 2 954 proficiency test results, obtained from 22 positive samples of 6 proficiency tests in 155 laboratories conducted by China CDC were analyzed during 2013-2015. The results from each sample were first logarithmic transformed and then grouped according to the method used, the mean value of logarithmic results was calculated. Subsequently, 22 clusters of mean values were analyzed by Bland-Altman analysis for the consistency, and linear regression analysis for the interdependency. Results: The results indicated that, by taking Taqman as the reference, EasyQ, M2000, bDNA and domestic kit had good consistency (90 % -100 % ) and interdependency. Conclusion: All the viral load tests were bio-equivalent. Moreover, according to the conversion formula derived from domestic proficiency test results, all the viral load results could be converted, which is critical for epidemiological analysis.

  1. Prevalence of exon 11 internal tandem duplications in the C-KIT proto-oncogene in Australian canine mast cell tumours.

    PubMed

    Tamlin, V S; Kessell, A E; Mccoy, R J; Dobson, E C; Smith, T S; Hebart, M; Brown, L; Mitrovic, D; Peaston, A E

    2017-10-01

    To measure the prevalence of internal tandem duplications (ITDs) in exon 11 of the proto-oncogene C-KIT in a sample of Australian cutaneous canine mast cell tumours (MCTs) drawn from general practice and to evaluate relationships between tumour mutation status and prognostic factors including signalment, tumour histological grade, tumour anatomical location and tumour size. C-KIT exon 11 ITDs were detected by PCR in DNA extracted from formalin-fixed, paraffin-embedded canine MCTs sourced from three veterinary diagnostic laboratories in Adelaide and Melbourne. Tumours were graded according to two different systems (Patnaik and Kiupel systems) by board-certified anatomical pathologists blinded to the PCR results. Relationships between tumour mutation status and prognostic factors were evaluated using a generalised binary logistic regression analysis. ITDs were identified in 13 of 74 cutaneous canine MCT samples, giving an overall prevalence of 17.6% (95% confidence interval: 8.9-26.2%). ITDs were detected in 10 of 18 Patnaik grade III MCTs (55.6%) and 11 of 22 Kiupel high-grade MCTs (50%). Wald chi-square analysis revealed that detection of tumour ITDs was significantly associated with both Patnaik's and Kiupel's histologic grading systems (each: P < 0.001). The presence of the ITDs in MCTs was not associated with signalment, tumour anatomical location or tumour size. The prevalence of C-KIT exon 11 ITDs in Australian canine MCTs is similar to the prevalence in overseas canine populations (overall prevalence in Australia approximately 18%). ITDs were more frequently identified in higher grade MCTs. © 2017 Australian Veterinary Association.

  2. Home-based chlamydia testing of young people attending a music festival--who will pee and post?

    PubMed

    Sacks-Davis, Rachel; Gold, Judy; Aitken, Campbell K; Hellard, Margaret E

    2010-06-28

    Chlamydia is most common among young people, but only a small proportion of Australian young people are tested annually. Home-based chlamydia testing has been piloted in several countries to increase testing rates, but uptake has been low. We aimed to identify predictors of uptake of home-based chlamydia testing to inform future testing programs. We offered home-based chlamydia testing kits to participants in a sexual behaviour cross-sectional survey conducted at a music festival in Melbourne, Australia. Those who consented received a testing kit and were asked to return their urine or vaginal swab sample via post. Nine hundred and two sexually active music festival attendees aged 16-29 completed the survey; 313 (35%) opted to receive chlamydia testing kits, and 67 of 313 (21%) returned a specimen for testing. One participant was infected with chlamydia (1% prevalence). Independent predictors of consenting to receive a testing kit included older age, knowing that chlamydia can make women infertile, reporting more than three lifetime sexual partners and inconsistent condom use. Independent predictors of returning a sample to the laboratory included knowing that chlamydia can be asymptomatic, not having had an STI test in the past six months and not living with parents. A low proportion of participants returned their chlamydia test, suggesting that this model is not ideal for reaching young people. Home-based chlamydia testing is most attractive to those who report engaging in sexual risk behaviours and are aware of the often asymptomatic nature and potential sequelae of chlamydia infection.

  3. Home-based chlamydia testing of young people attending a music festival - who will pee and post?

    PubMed Central

    2010-01-01

    Background Chlamydia is most common among young people, but only a small proportion of Australian young people are tested annually. Home-based chlamydia testing has been piloted in several countries to increase testing rates, but uptake has been low. We aimed to identify predictors of uptake of home-based chlamydia testing to inform future testing programs. Methods We offered home-based chlamydia testing kits to participants in a sexual behaviour cross-sectional survey conducted at a music festival in Melbourne, Australia. Those who consented received a testing kit and were asked to return their urine or vaginal swab sample via post. Results Nine hundred and two sexually active music festival attendees aged 16-29 completed the survey; 313 (35%) opted to receive chlamydia testing kits, and 67 of 313 (21%) returned a specimen for testing. One participant was infected with chlamydia (1% prevalence). Independent predictors of consenting to receive a testing kit included older age, knowing that chlamydia can make women infertile, reporting more than three lifetime sexual partners and inconsistent condom use. Independent predictors of returning a sample to the laboratory included knowing that chlamydia can be asymptomatic, not having had an STI test in the past six months and not living with parents. Conclusions A low proportion of participants returned their chlamydia test, suggesting that this model is not ideal for reaching young people. Home-based chlamydia testing is most attractive to those who report engaging in sexual risk behaviours and are aware of the often asymptomatic nature and potential sequelae of chlamydia infection. PMID:20584287

  4. Allele-Specific Polymerase Chain Reaction for the Imatinib-Resistant KIT D816V and D816F Mutations in Mastocytosis and Acute Myelogenous Leukemia

    PubMed Central

    Corless, Christopher L.; Harrell, Patina; Lacouture, Mario; Bainbridge, Troy; Le, Claudia; Gatter, Ken; White, Clifton; Granter, Scott; Heinrich, Michael C.

    2006-01-01

    Oncogenic mutations of the receptor tyrosine kinase KIT contribute to the pathogenesis of gastrointestinal stromal tumors, systemic mastocytosis (SM), and some cases of acute myelogenous leukemia (AML). The D816V substitution in the activation loop of KIT results in relative resistance to the kinase inhibitor imatinib (Gleevec). Because this mutation occurs in 80 to 95% of adult SM, its detection has diagnostic and predictive significance. Unfortunately, the fraction of mutation-positive cells in clinical SM samples is often below the 20 to 30% threshold needed for detection by direct DNA sequencing. We have developed an allele-specific polymerase chain reaction assay using a mutation-specific primer combined with a wild-type blocking oligonucleotide that amplifies D816V at the level of 1% mutant allele in DNA extracted from formalin-fixed, paraffin-embedded tissue. There were no amplifications among 64 KIT wild-type tumors and cell lines, whereas all D816V-mutant samples (eight AML and 11 mast cell disease) were positive. Other D816 substitutions associated with resistance to imatinib in vitro are rare in SM. Among these D816F was detectable with the assay whereas D816H, D816Y, and D816G did not amplify. Nine biopsies (bone marrow, skin, or colon) with suspected SM were negative by denaturing high performance liquid chromatography and/or DNA sequencing but positive by allele-specific polymerase chain reaction. Thus, the assay may be useful in confirming the diagnosis of SM. PMID:17065430

  5. CCR4 is expressed on infiltrating cells in lesional skin of early mycosis fungoides and atopic dermatitis.

    PubMed

    Sugaya, Makoto; Morimura, Sohshi; Suga, Hiraku; Kawaguchi, Makiko; Miyagaki, Tomomitsu; Ohmatsu, Hanako; Fujita, Hideki; Sato, Shinichi

    2015-06-01

    CCR4 is expressed on tumor cells of mycosis fungoides (MF) and Sézary syndrome (SS). In MF, most infiltrating cells in patches and plaques express CXCR3, while tumor cells express CCR4 in advanced stages. Poteligeo Test IHC (CCR4 staining kit) is a newly developed staining kit that can examine the presence of CCR4 expressed on tumor cells of adult T-cell leukemia/lymphoma, peripheral T-cell lymphoma and cutaneous T-cell lymphoma before treatment of anti-CCR4 antibody using paraffin-embedded samples. In this study, we analyzed CCR4 expression in lesional skin of MF, SS, atopic dermatitis (AD) and psoriasis with this new kit. CCR4 was expressed on infiltrating cells in lesional skin of patch, plaque, tumor MF and SS, and the number of positive cells increased as the disease progressed. Immunohistochemistry with frozen sections also showed some positive cells scattered in the dermis, although the quality was not high enough to quantify positive cells. There were significant positive correlations between CCR4(+) cells and serum lactate dehydrogenase levels. Interestingly, CCR4(+) cells were also detected in AD skin, whose number was larger than that in psoriatic skin. Previous studies showed only scattered CCR4(+) cells in skin samples by standard immunohistochemical staining. The new, sensitive CCR4 staining kit has revealed that CCR4 is expressed on infiltrating cells in lesional skin of early MF and AD as well as advanced MF and SS. These cells can be therapeutic targets for patients who are resistant to standard treatments. © 2015 Japanese Dermatological Association.

  6. From clinical sample to complete genome: Comparing methods for the extraction of HIV-1 RNA for high-throughput deep sequencing.

    PubMed

    Cornelissen, Marion; Gall, Astrid; Vink, Monique; Zorgdrager, Fokla; Binter, Špela; Edwards, Stephanie; Jurriaans, Suzanne; Bakker, Margreet; Ong, Swee Hoe; Gras, Luuk; van Sighem, Ard; Bezemer, Daniela; de Wolf, Frank; Reiss, Peter; Kellam, Paul; Berkhout, Ben; Fraser, Christophe; van der Kuyl, Antoinette C

    2017-07-15

    The BEEHIVE (Bridging the Evolution and Epidemiology of HIV in Europe) project aims to analyse nearly-complete viral genomes from >3000 HIV-1 infected Europeans using high-throughput deep sequencing techniques to investigate the virus genetic contribution to virulence. Following the development of a computational pipeline, including a new de novo assembler for RNA virus genomes, to generate larger contiguous sequences (contigs) from the abundance of short sequence reads that characterise the data, another area that determines genome sequencing success is the quality and quantity of the input RNA. A pilot experiment with 125 patient plasma samples was performed to investigate the optimal method for isolation of HIV-1 viral RNA for long amplicon genome sequencing. Manual isolation with the QIAamp Viral RNA Mini Kit (Qiagen) was superior over robotically extracted RNA using either the QIAcube robotic system, the mSample Preparation Systems RNA kit with automated extraction by the m2000sp system (Abbott Molecular), or the MagNA Pure 96 System in combination with the MagNA Pure 96 Instrument (Roche Diagnostics). We scored amplification of a set of four HIV-1 amplicons of ∼1.9, 3.6, 3.0 and 3.5kb, and subsequent recovery of near-complete viral genomes. Subsequently, 616 BEEHIVE patient samples were analysed to determine factors that influence successful amplification of the genome in four overlapping amplicons using the QIAamp Viral RNA Kit for viral RNA isolation. Both low plasma viral load and high sample age (stored before 1999) negatively influenced the amplification of viral amplicons >3kb. A plasma viral load of >100,000 copies/ml resulted in successful amplification of all four amplicons for 86% of the samples, this value dropped to only 46% for samples with viral loads of <20,000 copies/ml. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  7. Molecular Diagnosis of Invasive Aspergillosis and Detection of Azole Resistance by a Newly Commercialized PCR Kit.

    PubMed

    Dannaoui, Eric; Gabriel, Frédéric; Gaboyard, Manuel; Lagardere, Gaëlle; Audebert, Lucile; Quesne, Gilles; Godichaud, Sandrine; Verweij, Paul E; Accoceberry, Isabelle; Bougnoux, Marie-Elisabeth

    2017-11-01

    Aspergillus fumigatus is the main species responsible for aspergillosis in humans. The diagnosis of aspergillosis remains difficult, and the rapid emergence of azole resistance in A. fumigatus is worrisome. The aim of this study was to validate the new MycoGENIE A. fumigatus real-time PCR kit and to evaluate its performance on clinical samples for the detection of A. fumigatus and its azole resistance. This multiplex assay detects DNA from the A. fumigatus species complex by targeting the multicopy 28S rRNA gene and specific TR 34 and L98H mutations in the single-copy-number cyp51A gene of A. fumigatus The specificity of cyp51A mutation detection was assessed by testing DNA samples from 25 wild-type or mutated clinical A. fumigatus isolates. Clinical validation was performed on 88 respiratory samples obtained from 62 patients and on 69 serum samples obtained from 16 patients with proven or probable aspergillosis and 13 patients without aspergillosis. The limit of detection was <1 copy for the Aspergillus 28S rRNA gene and 6 copies for the cyp51A gene harboring the TR 34 and L98H alterations. No cross-reactivity was detected with various fungi and bacteria. All isolates harboring the TR 34 and L98H mutations were accurately detected by quantitative PCR (qPCR) analysis. With respiratory samples, qPCR results showed a sensitivity and specificity of 92.9% and 90.1%, respectively, while with serum samples, the sensitivity and specificity were 100% and 84.6%, respectively. Our study demonstrated that this new real-time PCR kit enables sensitive and rapid detection of A. fumigatus DNA and azole resistance due to TR 34 and L98H mutations in clinical samples. Copyright © 2017 American Society for Microbiology.

  8. 49 CFR 173.161 - Chemical kits and first aid kits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Chemical kits and first aid kits. 173.161 Section... Class 7 § 173.161 Chemical kits and first aid kits. (a) Chemical kits and First aid kits must conform to... 10 kg. (b) Chemical kits and First aid kits are excepted from the specification packaging...

  9. COMPARISON OF IMMUNOASSAY AND GAS CHROMATOGRAPHY/MASS SPECTROMETRY METHODS FOR MEASURING 3,5,6-TRICHLORO-2PYRIDINOL IN MULTIPLE SAMPLE MEDIA

    EPA Science Inventory

    Two enzyme-linked immunosorbent assay (ELISA) methods were evaluated for the determination of 3,5,6-trichloro-2-pyridinol (3,5,6-TCP) in multiple sample media (dust, soil, food, and urine). The dust and soil samples were analyzed by a commercial RaPID immunoassay testing kit. ...

  10. 46 CFR Appendix D to Subpart C of... - Sampling and Analytical Methods for Benzene Monitoring-Measurement Procedures

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... samples are analyzed directly by high performance liquid chromatography (HPLC). Detection limits: 0.01% by... proper selection of HPLC parameters. 2.4. Samples must be free of any particulates that may clog the... clarification kit. 3. Apparatus 3.1. Liquid chromatograph equipped with a UV detector. 3.2. HPLC Column that...

  11. 46 CFR Appendix D to Subpart C of... - Sampling and Analytical Methods for Benzene Monitoring-Measurement Procedures

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... samples are analyzed directly by high performance liquid chromatography (HPLC). Detection limits: 0.01% by... proper selection of HPLC parameters. 2.4. Samples must be free of any particulates that may clog the... clarification kit. 3. Apparatus 3.1. Liquid chromatograph equipped with a UV detector. 3.2. HPLC Column that...

  12. 46 CFR Appendix D to Subpart C of... - Sampling and Analytical Methods for Benzene Monitoring-Measurement Procedures

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... samples are analyzed directly by high performance liquid chromatography (HPLC). Detection limits: 0.01% by... proper selection of HPLC parameters. 2.4. Samples must be free of any particulates that may clog the... clarification kit. 3. Apparatus 3.1. Liquid chromatograph equipped with a UV detector. 3.2. HPLC Column that...

  13. 9 CFR 146.13 - Testing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...

  14. 9 CFR 146.13 - Testing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...

  15. 9 CFR 146.13 - Testing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...

  16. 9 CFR 146.13 - Testing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...

  17. 9 CFR 146.13 - Testing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...

  18. 49 CFR 173.161 - Chemical kits and first aid kits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Chemical kits and first aid kits. 173.161 Section... Class 7 § 173.161 Chemical kits and first aid kits. (a) Applicability. Chemical kits and first aid kits... assigned to the chemical kit and first aid kit as a whole must be the most stringent packing group assigned...

  19. Performance and diagnostic usefulness of commercially available enzyme linked immunosorbent assay and rapid kits for detection of HIV, HBV and HCV in India.

    PubMed

    Maity, Susmita; Nandi, Srijita; Biswas, Subrata; Sadhukhan, Salil Kumar; Saha, Malay Kumar

    2012-11-26

    HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn't vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p < 0.01) among three kit types. ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for further detection of false positive samples. ELISA seems the appropriate assay in blood bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful.

  20. Performance and diagnostic usefulness of commercially available enzyme linked immunosorbent assay and rapid kits for detection of HIV, HBV and HCV in India

    PubMed Central

    2012-01-01

    Background HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. Results A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn’t vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p < 0.01) among three kit types. Conclusions ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for further detection of false positive samples. ELISA seems the appropriate assay in blood bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful. PMID:23181517

  1. Internal associations and dynamic expression of c-kit and nanog genes in ventricular remodelling induced by adriamycin.

    PubMed

    Liu, Zhen; Li, Shuo; Liu, Lingling; Guo, Zhikun; Wang, Pengfei

    2016-09-01

    The present study aimed to investigate the dynamic expression of the c-kit and nanog genes in rats with left ventricular remodelling induced by adriamycin (ADR), and explore its internal association and mechanism of action. Sprague-Dawley male rats were randomly divided into a normal control group and a heart failure model group. Heart failure was induced by a single intraperitoneal injection of ADR (4 mg/kg) weekly for six weeks. The normal control group was given the same amount of saline. At the eighth week, rat cardiac function was examined to demonstrate the formation of heart failure. The rat hearts were harvested frozen and sectioned, and the expression levels of the nanog and c-kit genes in the myocardial tissue samples were detected using immunohistochemistry, immunofluorescence and reverse transcription-polymerase chain reaction (RT-PCR). Hematoxylin and eosin staining demonstrated various pathological changes in the myocardial cells in the heart failure model group, whereas myocardial infarction was not observed in the normal control group. Immunohistochemistry and immunofluorescence demonstrated that nanog-positive cells were predominantly expressed in the vascular endothelium, with a few myocardial cells and stem cells in normal myocardium. The expression levels of c-kit and nanog in the myocardium of the rats with heart failure decreased significantly. c-kit-positive cells clustered together in the epicardium and its vicinity, and c-kit expression significantly decreased in the myocardium of rats with heart failure, as compared with normal rats. In both groups, some cells co-expressed both the c-kit and nanog genes. The RT-PCR results demonstrated that the expression levels of the two genes in the heart failure model group were significantly lower compared with those in the normal control group (P<0.05). In conclusion, the c-kit- and nanog-positive stem cells decreased in the myocardium of the rats with left ventricular remodelling induced by ADR. Their abnormal expression was significantly correlated with left ventricular remodelling, thereby indicating an internal association (influences of two indexes in the experimental group and control group) between them.

  2. Microbial community structures in high rate algae ponds for bioconversion of agricultural wastes from livestock industry for feed production.

    PubMed

    Mark Ibekwe, A; Murinda, Shelton E; Murry, Marcia A; Schwartz, Gregory; Lundquist, Trygve

    2017-02-15

    Dynamics of seasonal microbial community compositions in algae cultivation ponds are complex. However, there is very limited knowledge on bacterial communities that may play significant roles with algae in the bioconversion of manure nutrients to animal feed. In this study, water samples were collected during winter, spring, summer, and fall from the dairy lagoon effluent (DLE), high rate algae ponds (HRAP) that were fed with diluted DLE, and municipal waste water treatment plant (WWTP) effluent which was included as a comparison system for the analysis of total bacteria, Cyanobacteria, and microalgae communities using MiSeq Illumina sequencing targeting the 16S V4 rDNA region. The main objective was to examine dynamics in microbial community composition in the HRAP used for the production of algal biomass. DNA was extracted from the different sample types using three commercially available DNA extraction kits; MoBio Power water extraction kit, Zymo fungi/bacterial extraction kit, and MP Biomedicals FastDNA SPIN Kit. Permutational analysis of variance (PERMANOVA) using distance matrices on each variable showed significant differences (P=0.001) in beta-diversity based on sample source. Environmental variables such as hydraulic retention time (HRT; P<0.031), total N (P<0.002), total inorganic N (P<0.002), total P (P<0.002), alkalinity (P<0.002), pH (P<0.022), total suspended solid (TSS; P<0.003), and volatile suspended solids (VSS; P<0.002) significantly affected microbial communities in DLE, HRAP, and WWTP. Of the operational taxonomic units (OTUs) identified to phyla level, the dominant classes of bacteria identified were: Cyanobacteria, Alpha-, Beta-, Gamma-, Epsilon-, and Delta-proteobacteria, Bacteroidetes, Firmicutes, and Planctomycetes. Our data suggest that microbial communities were significantly affected in HRAP by different environmental variables, and care must be taken in extraction procedures when evaluating specific groups of microbial communities for specific functions. Published by Elsevier B.V.

  3. Health-related quality of life in children with chronic immune thrombocytopenia in China.

    PubMed

    Zhang, Heng; Wang, Li; Quan, Meijie; Huang, Jie; Wu, Peng; Lu, Qin; Fang, Yongjun

    2016-03-15

    The concept of health-related quality of life (HRQoL) was brought up decades ago and has been well utilized in many different areas. Regarding immune thrombocytopenia (ITP) management, much work has been done to emphasize the necessity of taking HRQoL into consideration. However, data on HRQoL of children with chronic ITP remain rare. This is a cross-sectional study. Children with chronic ITP aged from 2 to 18 and their parents were recruited. Participants completed the Pediatric Quality of Life Inventory™ (PedsQL™) and Kids' ITP Tools (KIT) questionnaires at only one time. The Pearson's correlation was examined between these measures for the pooled samples. A total of 42 families participated. Mean child self-report scores of KIT and PedsQL™ were 78.60 (SD = 12.40) and 85.13 (SD = 14.12), respectively, corresponding to parent proxy report scores, which were 73.40 (SD = 19.96) and 85.10 (SD = 13.56), respectively. Mean score of KIT parent impact report was only 40.39 (SD = 19.96). Significantly higher KIT scores (self-report and parent proxy) were observed in children with PLT more than 30 × 10*9/L compared to others, and this difference was even more noticeable in the PedsQL™ parent proxy report group (p < 0.001). As with intravenous immunoglobulin, the statistics difference appeared only in KIT child self-report group (p = 0.03), while for bone marrow examination, the difference appeared only in PedsQL™ parent proxy report group (p = 0.01). A negative relationship was apparent between duration of disease and scores. Gender and use of corticosteroids had no impact on the KIT and PedsQL™ scores here. Internal consistency reliability was demonstrated with Cronbach's alpha for all scales above the acceptable level of 0.89 (range from 0.88 to 0.97). There was a substantial concordance (p < 0.001) between the child and parent proxy scores (ICC for KIT is 0.59, ICC for PedsQL™ is 0.85). Meanwhile, KIT scores are correlated with PedsQL™ (r = 0.75 for child self report, r = 0.61 for parent proxy report). ITP affects HRQoL of children and parents. Parents are much more concerned with the disease than their children, which seriously influence their HRQoL as a result. The cross-culture translated KIT is reliable and valid with acceptable correlation to the PedsQL™. KIT provides valuable information of childhood ITP and will be a reliable outcome measure for further clinical research on HRQoL.

  4. Library Construction from Subnanogram DNA for Pelagic Sea Water and Deep-Sea Sediments

    PubMed Central

    Hirai, Miho; Nishi, Shinro; Tsuda, Miwako; Sunamura, Michinari; Takaki, Yoshihiro; Nunoura, Takuro

    2017-01-01

    Shotgun metagenomics is a low biased technology for assessing environmental microbial diversity and function. However, the requirement for a sufficient amount of DNA and the contamination of inhibitors in environmental DNA leads to difficulties in constructing a shotgun metagenomic library. We herein examined metagenomic library construction from subnanogram amounts of input environmental DNA from subarctic surface water and deep-sea sediments using two library construction kits: the KAPA Hyper Prep Kit and Nextera XT DNA Library Preparation Kit, with several modifications. The influence of chemical contaminants associated with these environmental DNA samples on library construction was also investigated. Overall, shotgun metagenomic libraries were constructed from 1 pg to 1 ng of input DNA using both kits without harsh library microbial contamination. However, the libraries constructed from 1 pg of input DNA exhibited larger biases in GC contents, k-mers, or small subunit (SSU) rRNA gene compositions than those constructed from 10 pg to 1 ng DNA. The lower limit of input DNA for low biased library construction in this study was 10 pg. Moreover, we revealed that technology-dependent biases (physical fragmentation and linker ligation vs. tagmentation) were larger than those due to the amount of input DNA. PMID:29187708

  5. Determining the profiles and parameters for gene amplification testing of growth factor receptors in lung cancer.

    PubMed

    Pros, Eva; Lantuejoul, Sylvie; Sanchez-Verde, Lydia; Castillo, Sandra D; Bonastre, Ester; Suarez-Gauthier, Ana; Conde, Esther; Cigudosa, Juan C; Lopez-Rios, Fernando; Torres-Lanzas, Juan; Castellví, Josep; Ramon y Cajal, Santiago; Brambilla, Elisabeth; Sanchez-Cespedes, Montse

    2013-08-15

    Growth factor receptors (GFRs) are amenable to therapeutic intervention in cancer and it is important to select patients appropriately. One of the mechanisms for activation of GFRs is gene amplification (GA) but discrepancies arising from the difficulties associated with data interpretation and the lack of agreed parameters confound the comparison of results from different laboratories. Here, we attempt to establish appropriate conditions for standardization of the determination of GA in a panel of GFRs. A NSCLC tissue microarray panel containing 302 samples was screened for alterations at ALK, FGFR1, FGFR2, FGFR3, ERBB2, IGF1R, KIT, MET and PDGFRA by FISH, immunostaining and/or real-time quantitative RT-PCR. Strong amplification was found for FGFR1, ERBB2, KIT/PDFGRA and MET, with frequencies ranging from 1 to 6%. Thresholds for overexpression and GA were established. Strong immunostaining was found in most tumors with ERBB2, MET and KIT amplification, although some tumors underwent strong immunostaining in the absence of GA. KIT and PDFGRA were always coamplified, but only one tumor showed PDGFRA overexpression, indicating that KIT is the main target. Amplification of FGFR1 predominated in squamous cell carcinomas, although the association with overexpression was inconclusive. Interestingly, alterations at ALK, MET, EGFR, ERBB2 and KRAS correlated with augmented levels of phospho-S6 protein, suggesting activation of the mTOR pathway, which may prove useful to pre-select tumors for testing. Overall, here, we provide with parameters for the determination of GA at ERBB2, MET, KIT and PDGFRA which could be implemented in the clinic to stratify lung cancer patients for specific treatments. Copyright © 2013 UICC.

  6. Evaluation of HIV/AIDS diagnostics kits and formulation of a testing strategy for Pakistan.

    PubMed

    Waheed, Usman; Hayat, Khizar; Ahmad, Bashir; Waheed, Yasir; Zaheer, Hasan Abbas

    2013-04-01

    Rapid diagnosis of HIV/AIDS enables the development of prevention and treatment programmes but accurate, reliable and cost effective testing strategies should be used for testing of HIV/AIDS from a large population. To evaluate the performance and effectiveness of three assays for the diagnosis of HIV in comparison with Western blot and to formulate an alternative cost-effective confirmatory approach for HIV diagnosis. 472 specimens (serum) from a Pakistani population were evaluated. Two rapid HIV testing kits (Capillus, SD Bioline) and one ELISA (Vironostika Ag/Ab) kit were used to detect HIV. Results were compared with Western blot against which sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of all HIV assays were assessed. 280/472 (59.3%) of the samples were positive for antibodies against purified HIV-1 viral proteins. The sensitivity of SD Bioline and Vironostika ELISA was 100% (95% CI; 98-100) while that of anti-HIV Capillus™ kit was 94.6% (95% CI; 91-96.8). The specificity of the Vironostika ELISA and anti-HIV Capillus™ kit was 100% (95% CI; 97-100) while specificity of SD Bioline was 98.4% (95% CI; 95-99). PPV was 100% (95% CI; 98-100%) for the anti-HIV Capillus™ and Vironostika ELISA and 98.9% (95% CI; 96-99%) for SD Bioline. NPV for SD Bioline and Vironostika ELISA was 100% (95% CI; 98-100%) and 92.7% for anti-HIV Capillus™ (95% CI; 88-96%). The sensitivity and specificity of all three kits were satisfactory compared to Western blot and could be used for effective diagnosis of HIV/AIDS in Pakistani population. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Samsung Salmonella Detection Kit. AOAC Performance Tested Method(SM) 021203.

    PubMed

    Li, Jun; Cheung, Win Den; Opdyke, Jason; Harvey, John; Chong, Songchun; Moon, Cheol Gon

    2012-01-01

    Salmonella, one of the most common causes of foodborne illness, is a significant public health concern worldwide. There is a need in the food industry for methods that are simple, rapid, and sensitive for the detection of foodborne pathogens. In this study, the Samsung Salmonella Detection Kit, a real-time PCR assay for the detection of Salmonella, was evaluated according to the current AOAC guidelines. The validation consisted of lot-to-lot consistency, stability, robustness, and inclusivity/exclusivity studies, as well as a method comparison of 10 different food matrixes. In the validation, the Samsung Salmonella Detection Kit was used in conjunction with the Applied Biosystems StepOnePlus PCR system and the Samsung Food Testing Software for the detection of Salmonella species. The performance of the assays was compared to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG) 4.05: Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg, and Catfish and the and U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) Chapter 5 Salmonella reference methods. The validation was conducted using an unpaired study design for detection of Salmonella spp. in raw ground beef, raw pork, raw ground pork, raw chicken wings, raw salmon, alfalfa sprouts, pasteurized orange juice, peanut butter, pasteurized whole milk, and shell eggs. The Samsung Salmonella Detection Kit demonstrated lot-to-lot consistency among three independent lots as well as ruggedness with minor modifications to changes in enrichment incubation time, enrichment incubation temperature, and DNA sample volume for PCR reaction. Stability was observed for 13 months at -20 degrees C and 3 months at 5 degrees C. For the inclusivity/exclusivity study, the Samsung Salmonella Detection Kit correctly identified 147 Salmonella species isolates out of 147 isolates tested from each of three different enrichment broths (a total of 441 isolates detected), and correctly excluded all 31 nontarget strains analyzed. For the method comparison, statistical analysis was conducted according to the Mantel-Haenszel Chi-square formula for unpaired test portions, and there was no significant difference in the number of positive samples detected between the Samsung Salmonella Detection Kit and the USDA/FSIS-MLG and FDA/BAM reference methods for all 10 food matrixes.

  8. Factors associated with use and non-use of the Fecal Immunochemical Test (FIT) kit for Colorectal Cancer Screening in Response to a 2012 outreach screening program: a survey study.

    PubMed

    Gordon, Nancy P; Green, Beverly B

    2015-06-11

    The one-sample fecal immunochemical test (FIT) is gaining popularity for colorectal cancer (CRC) screening of average-risk people. However, uptake and annual use remain suboptimal. In 2013, we mailed questionnaires to three groups of nonHispanic White, Black, and Latino Kaiser Permanente Northern California (KPNC) members ages 52-76 who received FIT kits in 2010-2012: Continuers did the FIT all 3 years; Converts in 2012, but not 2010 or 2011; and Nonusers in none of the 3 years. The questionnaires covered social influences, perceived CRC risk, reasons for using (Continuers, Converts) or avoiding using (Nonusers) the FIT, and recommendations for improving the kit. Continuers (n = 607, response rate 67.5%), Converts (n = 317, response rate 35.6%), and Nonusers (n = 215, response rate 21.1%) did not differ in perceived risk or family history of CRC, but Nonusers were less likely than Continuers and Converts to know someone who had polyps or CRC. Continuers, Converts, and Nonusers did not differ in social network encouragement of CRC screening, but did differ in believing that it was very important that they be screened (88.3%, 68.4%, 47.7%) and that their medical team thought it very important that they be screened (88.6%, 79.9%, 53.9%). Approximately half of Continuers and Converts completed the FIT to please their doctor. Converts were less likely than Continuers to use the FIT to "make sure they were OK" (53.7% vs. 72.6%) or "protect their health" (46.1% vs. 76.4%). Nearly half of Converts completed the FIT out of guilt. Approximately half of FIT kit users suggested adding a disposable glove, extra paper, and wider-mouth tube to the kit. Nonusers' reasons for not using the FIT included discomfort, disgust, or embarrassment (59.6%); thinking it unnecessary (32.9%); fatalism/fear (15.5%); and thinking it too difficult to use (14.5%), but <10% did not want CRC screening at all. Nonusers and irregular users of the FIT are less intrinsically motivated to get CRC screening than long-term users and more averse to preparing their stool sample. Changes to the FIT kit to address discomfort and difficulty factors might improve uptake and continued use.

  9. Meat species identification and Halal authentication using PCR analysis of raw and cooked traditional Turkish foods.

    PubMed

    Ulca, Pelin; Balta, Handan; Çağın, Ilknur; Senyuva, Hamide Z

    2013-07-01

    The method performance characteristics of commercially available PCR kits for animal species identification were established. Comminuted meat products containing different levels of pork were prepared from authentic beef, chicken, and turkey. These meat products were analysed in the raw state and after cooking for 20 min at 200 °C. For both raw and cooked meats, the PCR kit could correctly identify the animal species and could reliably detect the addition of pork at a level below 0.1%. A survey of 42 Turkish processed meat products such as soudjouk, salami, sausage, meatball, cured spiced beef and doner kebap was conducted. Thirty-six samples were negative for the presence of pork (<0.1%) and four were found to be correctly labelled as containing pork. However, one sausage sample was labelled as containing 5% beef, but beef DNA was not detected and a meatball sample labelled as 100% beef was found to contain chicken. Another turkey meatball sample was predominantly chicken. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. SMART Digest™ compared with pellet digestion for analysis of human immunoglobulin G1 in rat serum by liquid chromatography tandem mass spectrometry.

    PubMed

    Lanshoeft, Christian; Heudi, Olivier; Cianférani, Sarah

    2016-05-15

    The newly developed SMART Digest™ kit was applied for the sample preparation of human immunoglobulin G1 (hIgG1) in rat serum prior to qualitative and quantitative analyses by liquid chromatography tandem mass spectrometry (LC-MS/MS). The sequence coverages obtained for the light and heavy chains of hIgG1A were 50 and 76%, respectively. The calibration curve was linear from 1.00 to 1000 μg/ml for three of four generic peptides. Overall, the SMART Digest™ kit resulted in similar quantitative data (linearity, sensitivity, accuracy, and precision) compared with the pellet digestion protocol. However, the SMART Digest™ required only 2 h of sample preparation with fewer reagents. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Cystic fibrosis screening using the College panel: platform comparison and lessons learned from the first 20,000 samples.

    PubMed

    Strom, Charles M; Huang, Donghui; Buller, Arlene; Redman, Joy; Crossley, Beryl; Anderson, Ben; Entwistle, Tom; Sun, Weimin

    2002-01-01

    To determine the accuracy of two commercially available kits for cystic fibrosis (CF) genotyping and determine allele frequencies for the ACMG/ACOG recommended mutations. A total of 1,040 consecutive analyses using Roche CF Gold Strips and the ABI CF Genotyper were performed. Subsequently we performed analyses of 20,103 samples. Both kits accurately determined CF genotypes. The I148T mutation was found >100 times more frequently in carrier screening than in CF patients. Asymptomatic patients were identified who are compound heterozygotes for delta F508 and I148T. Four of 13 patients heterozygous for delta F508 and the IVS8-5T polymorphism had some symptoms of CF. Accurate and timely analysis can be performed for the ACMG CF panel. I148T is a low penetrance CF allele.

  12. Performance Evaluation of the Real-Q Cytomegalovirus (CMV) Quantification Kit Using Two Real-Time PCR Systems for Quantifying CMV DNA in Whole Blood.

    PubMed

    Park, Jong Eun; Kim, Ji Youn; Yun, Sun Ae; Lee, Myoung Keun; Huh, Hee Jae; Kim, Jong Won; Ki, Chang Seok

    2016-11-01

    Standardized cytomegalovirus (CMV) DNA quantification is important for managing CMV disease. We evaluated the performance of the Real-Q CMV Quantification Kit (Real-Q assay; BioSewoom, Korea) using whole blood (WB), with nucleic acid extraction using MagNA Pure 96 (Roche Diagnostics, Germany). Real-time PCR was performed on two platforms: the 7500 Fast real-time PCR (7500 Fast; Applied Biosystems, USA) and CFX96 real-time PCR detection (CFX96; Bio-Rad, USA) systems. The WHO international standard, diluted with CMV-negative WB, was used to validate the analytical performance. We used 90 WB clinical samples for comparison with the artus CMV RG PCR kit (artus assay; Qiagen, Germany). Limits of detections (LODs) in 7500 Fast and CFX96 were 367 and 479 IU/mL, respectively. The assay was linear from the LOD to 10⁶ IU/mL (R² ≥0.9886). The conversion factors from copies to IU in 7500 Fast and CFX96 were 0.95 and 1.06, respectively. Compared with the artus assay, for values <1,000 copies/mL, 100% of the samples had a variation <0.7 log₁₀ copies/mL; >1,000 copies/mL, 73.3% and 80.6% of samples in 7500 Fast and CFX96, respectively, had <0.5 log₁₀ copies/mL. The Real-Q assay is useful for quantifying CMV in WB with the two real-time PCR platforms.

  13. Towards a new standardized method for circulating miRNAs profiling in clinical studies: Interest of the exogenous normalization to improve miRNA signature accuracy.

    PubMed

    Vigneron, Nicolas; Meryet-Figuière, Matthieu; Guttin, Audrey; Issartel, Jean-Paul; Lambert, Bernard; Briand, Mélanie; Louis, Marie-Hélène; Vernon, Mégane; Lebailly, Pierre; Lecluse, Yannick; Joly, Florence; Krieger, Sophie; Lheureux, Stéphanie; Clarisse, Bénédicte; Leconte, Alexandra; Gauduchon, Pascal; Poulain, Laurent; Denoyelle, Christophe

    2016-08-01

    Circulating miRNAs are promising biomarkers in oncology but have not yet been implemented in the clinic given the lack of concordance across studies. In order to increase the cross-studies reliability, we attempted to reduce and to control the circulating miRNA expression variability between patients. First, to maximize profiling signals and to reduce miRNA expression variability, three isolation kits were compared and the NucleoSpin(®) kit provided higher miRNA concentrations than the other widely used kits. Second, to control inter-sample variability during the profiling step, the exogenous miRNAs normalization method commonly used for RT-qPCR validation step was adapted to microarray experiments. Importantly, exogenous miRNAs presented two-fold lower inter-sample variability than the widely used endogenous miR-16-5p reflecting that the latter is subject to both biological and technical variability. Although Caenorhabditis elegans miRNAs isolation yields were heterogeneous, they correlated to each other and to their geometrical mean across samples. The normalization based on the geometrical mean of three exogenous miRNAs increased the correlation up-to 0.97 between the microarrays and individual RT-qPCR steps of circulating miRNAs expression. Overall, this new strategy open new avenue to identify reliable circulating miRNA signatures for translation into clinical practice. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Development of a novel protein chip for the detection of bluetongue virus in China.

    PubMed

    Xu, Q Y; Sun, E C; Feng, Y F; Li, J P; Lv, S; Zhang, Q; Wang, H X; Zhang, J K; Wu, D L

    2016-08-01

    Bluetongue (BT), which is caused by the BT virus (BTV), is an important disease in ruminants that leads to significant economic losses in the husbandry industry. To detect BTV-specific antibodies in serum, a protein chip detection method based on a novel solid supporting material known as polymer-coated initiator-integrated poly (dimethyl siloxane) (iPDMS) was developed. With a threshold of 25% (signal-to-noise percentage), the sensitivity and specificity of the protein chip were 98.6% and 94.8%, respectively. Furthermore, spot serum samples obtained from six provinces of China were tested with the protein chip and a commercially available BTV enzyme-linked immunosorbent assay (ELISA) kit (IDEXX). Of 615 samples, BTV-specific antibodies were detected in 200 (32.52%) by the protein chip and in 176 (28.62%) by the IDEXX BTV ELISA kit. Comparison of the protein chip with the commercial IDEXX BTV ELISA kit yielded the following spot serum detection results: a total coincidence, a negative coincidence and a positive coincidence of 95.12%, 99.28% and 86.5%, respectively. With the protein chip, the BTV-specific serum antibody was detected in samples from all six provinces, and the positive rates ranged from 4.12 to 74.4%. These results indicate that this protein chip detection method based on iPDMS is useful for the serological diagnosis of BTV infection and for epidemiological investigation. Copyright © 2016. Published by Elsevier B.V.

  15. Performance of the ForenSeqTM DNA Signature Prep kit on highly degraded samples.

    PubMed

    Fattorini, Paolo; Previderé, Carlo; Carboni, Ilaria; Marrubini, Giorgio; Sorçaburu-Cigliero, Solange; Grignani, Pierangela; Bertoglio, Barbara; Vatta, Paolo; Ricci, Ugo

    2017-04-01

    Next generation sequencing (NGS) is the emerging technology in forensic genomics laboratories. It offers higher resolution to address most problems of human identification, greater efficiency and potential ability to interrogate very challenging forensic casework samples. In this study, a trial set of DNA samples was artificially degraded by progressive aqueous hydrolysis, and analyzed together with the corresponding unmodified DNA sample and control sample 2800 M, to test the performance and reliability of the ForenSeq TM DNA Signature Prep kit using the MiSeq Sequencer (Illumina). The results of replicate tests performed on the unmodified sample (1.0 ng) and on scalar dilutions (1.0, 0.5 and 0.1 ng) of the reference sample 2800 M showed the robustness and the reliability of the NGS approach even from sub-optimal amounts of high quality DNA. The degraded samples showed a very limited number of reads/sample, from 2.9-10.2 folds lower than the ones reported for the less concentrated 2800 M DNA dilution (0.1 ng). In addition, it was impossible to assign up to 78.2% of the genotypes in the degraded samples as the software identified the corresponding loci as "low coverage" (< 50x). Amplification artifacts such as allelic imbalances, allele drop outs and a single allele drop in were also scored in the degraded samples. However, the ForenSeq TM DNA Sequencing kit, on the Illumina MiSeq, was able to generate data which led to the correct typing of 5.1-44.8% and 10.9-58.7% of 58 of the STRs and 92 SNPs, respectively. In all trial samples, the SNP markers showed higher chances to be typed correctly compared to the STRs. This NGS approach showed very promising results in terms of ability to recover genetic information from heavily degraded DNA samples for which the conventional PCR/CE approach gave no results. The frequency of genetic mistyping was very low, reaching the value of 1.4% for only one of the degraded samples. However, these results suggest that further validation studies and a definition of interpretation criteria for NGS data are needed before implementation of this technique in forensic genetics. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Field comparison of real-time polymerase chain reaction and bacterial culture for identification of bovine mastitis bacteria.

    PubMed

    Koskinen, M T; Wellenberg, G J; Sampimon, O C; Holopainen, J; Rothkamp, A; Salmikivi, L; van Haeringen, W A; Lam, T J G M; Pyörälä, S

    2010-12-01

    Fast and reliable identification of the microorganisms causing mastitis is important for management of the disease and for targeting antimicrobial treatment. Methods based on PCR are being used increasingly in mastitis diagnostics. Comprehensive field comparisons of PCR and traditional milk bacteriology have not been available. The results of a PCR kit capable of detecting 11 important etiological agents of mastitis directly from milk in 4h were compared with those of conventional bacterial culture (48h). In total, 1,000 quarter milk samples were taken from cows with clinical or subclinical mastitis, or from clinically healthy quarters with low somatic cell count (SCC). Bacterial culture identified udder pathogens in 600/780 (77%) of the clinical samples, whereas PCR identified bacteria in 691/780 (89%) of the clinical samples. The PCR analysis detected major pathogens in a large number of clinical samples that were negative for the species in culture. These included 53 samples positive for Staphylococcus aureus by PCR, but negative by culture. A total of 137 samples from clinical mastitis, 5 samples from subclinical mastitis, and 1 sample from a healthy quarter were positive for 3 or more bacterial species in PCR, whereas culture identified 3 or more species in 60 samples from clinical mastitis. Culture identified a species not targeted by the PCR test in 44 samples from clinical mastitis and in 9 samples from subclinical mastitis. Low SCC samples provided a small number of positive results both in culture (4/93; 4.3%) and by PCR (7/93; 7.5%). In conclusion, the PCR kit provided several benefits over conventional culture, including speed, automated interpretation of results, and increased sensitivity. This kit holds much promise as a tool to complement traditional methods in identification of pathogens. In conventional mastitis bacteriology, a sample with 3 or more species is considered contaminated, and resampling of the cow is recommended. Further study is required to investigate how high sensitivity of PCR and its quantitative features can be applied to improve separation of relevant udder pathogens from likely contaminants in samples where multiple species are detected. Furthermore, increasing the number of species targeted by the PCR test would be advantageous. Copyright © 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Introducing automation to the molecular diagnosis of Trypanosoma cruzi infection: A comparative study of sample treatments, DNA extraction methods and real-time PCR assays.

    PubMed

    Abras, Alba; Ballart, Cristina; Llovet, Teresa; Roig, Carme; Gutiérrez, Cristina; Tebar, Silvia; Berenguer, Pere; Pinazo, María-Jesús; Posada, Elizabeth; Gascón, Joaquim; Schijman, Alejandro G; Gállego, Montserrat; Muñoz, Carmen

    2018-01-01

    Polymerase chain reaction (PCR) has become a useful tool for the diagnosis of Trypanosoma cruzi infection. The development of automated DNA extraction methodologies and PCR systems is an important step toward the standardization of protocols in routine diagnosis. To date, there are only two commercially available Real-Time PCR assays for the routine laboratory detection of T. cruzi DNA in clinical samples: TCRUZIDNA.CE (Diagnostic Bioprobes Srl) and RealCycler CHAG (Progenie Molecular). Our aim was to evaluate the RealCycler CHAG assay taking into account the whole process. We assessed the usefulness of an automated DNA extraction system based on magnetic particles (EZ1 Virus Mini Kit v2.0, Qiagen) combined with a commercially available Real-Time PCR assay targeting satellite DNA (SatDNA) of T. cruzi (RealCycler CHAG), a methodology used for routine diagnosis in our hospital. It was compared with a well-known strategy combining a commercial DNA isolation kit based on silica columns (High Pure PCR Template Preparation Kit, Roche Diagnostics) with an in-house Real-Time PCR targeting SatDNA. The results of the two methodologies were in almost perfect agreement, indicating they can be used interchangeably. However, when variations in protocol factors were applied (sample treatment, extraction method and Real-Time PCR), the results were less convincing. A comprehensive fine-tuning of the whole procedure is the key to successful results. Guanidine EDTA-blood (GEB) samples are not suitable for DNA extraction based on magnetic particles due to inhibition, at least when samples are not processed immediately. This is the first study to evaluate the RealCycler CHAG assay taking into account the overall process, including three variables (sample treatment, extraction method and Real-Time PCR). Our findings may contribute to the harmonization of protocols between laboratories and to a wider application of Real-Time PCR in molecular diagnostic laboratories associated with health centers.

  18. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.

    PubMed

    Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz

    The aim of this study was to evaluate the QuickVue ® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue ® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue ® RSV Test and viral load or specific strain. The QuickVue ® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue ® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  19. Comparison of direct boiling method with commercial kits for extracting fecal microbiome DNA by Illumina sequencing of 16S rRNA tags.

    PubMed

    Peng, Xin; Yu, Ke-Qiang; Deng, Guan-Hua; Jiang, Yun-Xia; Wang, Yu; Zhang, Guo-Xia; Zhou, Hong-Wei

    2013-12-01

    Low cost and high throughput capacity are major advantages of using next generation sequencing (NGS) techniques to determine metagenomic 16S rRNA tag sequences. These methods have significantly changed our view of microorganisms in the fields of human health and environmental science. However, DNA extraction using commercial kits has shortcomings of high cost and time constraint. In the present study, we evaluated the determination of fecal microbiomes using a direct boiling method compared with 5 different commercial extraction methods, e.g., Qiagen and MO BIO kits. Principal coordinate analysis (PCoA) using UniFrac distances and clustering showed that direct boiling of a wide range of feces concentrations gave a similar pattern of bacterial communities as those obtained from most of the commercial kits, with the exception of the MO BIO method. Fecal concentration by boiling method affected the estimation of α-diversity indices, otherwise results were generally comparable between boiling and commercial methods. The operational taxonomic units (OTUs) determined through direct boiling showed highly consistent frequencies with those determined through most of the commercial methods. Even those for the MO BIO kit were also obtained by the direct boiling method with high confidence. The present study suggested that direct boiling could be used to determine the fecal microbiome and using this method would significantly reduce the cost and improve the efficiency of the sample preparation for studying gut microbiome diversity. © 2013 Elsevier B.V. All rights reserved.

  20. Nuclease-resistant double-stranded DNA controls or standards for hepatitis B virus nucleic acid amplification assays

    PubMed Central

    2009-01-01

    Background Identical blood samples tested using different kits can give markedly different hepatitis B virus (HBV) DNA levels, which can cause difficulty in the interpretation of viral load. A universal double-stranded DNA control or standard that can be used in all commercial HBV DNA nucleic acid amplification assay kits is urgently needed. By aligning all HBV genotypes (A-H), we found that the surface antigen gene and precore-core gene regions of HBV are the most conserved regions among the different HBV genotypes. We constructed a chimeric fragment by overlapping extension polymerase chain reaction and obtained a 1,349-bp HBVC+S fragment. We then packaged the fragment into lambda phages using a traditional lambda phage cloning procedure. Results The obtained armored DNA was resistant to DNase I digestion and was stable, noninfectious to humans, and could be easily extracted using commercial kits. More importantly, the armored DNA may be used with all HBV DNA nucleic acid amplification assay kits. Conclusions The lambda phage packaging system can be used as an excellent expression platform for armored DNA. The obtained armored DNA possessed all characteristics of an excellent positive control or standard. In addition, this armored DNA is likely to be appropriate for all commercial HBV DNA nucleic acid amplification detection kits. Thus, the constructed armored DNA can probably be used as a universal positive control or standard in HBV DNA assays. PMID:20025781

  1. Development and clinical evaluation of a rapid diagnostic kit for feline leukemia virus infection.

    PubMed

    Kim, Won-Shik; Chong, Chom-Kyu; Kim, Hak-Yong; Lee, Gyu-Cheol; Jeong, Wooseog; An, Dong-Jun; Jeoung, Hye-Young; Lee, Jae-In; Lee, Young-Ki

    2014-01-01

    Feline leukemia virus (FeLV) causes a range of neoplastic and degenerative diseases in cats. To obtain a more sensitive and convenient diagnosis of the disease, we prepared monoclonal antibodies specific for the FeLV p27 to develop a rapid diagnostic test with enhanced sensitivity and specificity. Among these antibodies, we identified two clones (hybridomas 8F8B5 and 8G7D1) that specifically bound to FeLV and were very suitable for a diagnostic kit. The affinity constants for 8F8B5 and 8G7D1 were 0.35 × 10⁸ and 0.86 × 10⁸, respectively. To investigate the diagnostic abilities of the rapid kit using these antibodies, we performed several clinical studies. Assessment of analytical sensitivity revealed that the detection threshold of the rapid diagnostic test was 2 ng/mL for recombinant p27 and 12.5 × 10⁴ IU/mL for FeLV. When evaluating 252 cat sera samples, the kit was found to have a kappa value of 0.88 compared to polymerase chain reaction (PCR), indicating a significant correlation between data from the rapid diagnostic test and PCR. Sensitivity and specificity of the kit were 95.2% (20/21) and 98.5% (257/261), respectively. Our results demonstrated that the rapid diagnostic test would be a suitable diagnostic tool for the rapid detection of FeLV infection in cats.

  2. Differences in staining intensities affect reported occurrences and concentrations of Giardia spp. in surface drinking water sources.

    PubMed

    Alderisio, K A; Villegas, L F; Ware, M W; McDonald, L A; Xiao, L; Villegas, E N

    2017-12-01

    USEPA Method 1623, or its equivalent, is currently used to monitor for protozoan contamination of surface drinking water sources worldwide. At least three approved staining kits used for detecting Cryptosporidium and Giardia are commercially available. This study focuses on understanding the differences among staining kits used for Method 1623. Merifluor and EasyStain labelling kits were used to monitor Cryptosporidium oocyst and Giardia cyst densities in New York City's raw surface water sources. In the year following a change to the approved staining kits for use with Method 1623, an anomaly was noted in the occurrence of Giardia cysts in New York City's raw surface water. Specifically, Merifluor-stained samples had higher Giardia cyst densities as compared with those stained with EasyStain. Side by side comparison revealed significantly lower fluorescence intensities of Giardia muris as compared with Giardia duodenalis cysts when labelled with EasyStain. This study showed very poor fluorescence intensity signals by EasyStain on G. muris cysts resulting in lower cyst counts, while Merifluor, with its broader Giardia cyst staining specificity, resulted in higher cyst counts, when using Methods 1623. These results suggest that detected Giardia cyst concentrations are dependent on the staining kits used, which can result in a more or less conservative estimation of occurrences and densities of zoonotic Giardia cysts by detecting a broader range of Giardia species/Assemblages. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  3. Evaluation of commercial DNA and RNA extraction methods for high-throughput sequencing of FFPE samples.

    PubMed

    Kresse, Stine H; Namløs, Heidi M; Lorenz, Susanne; Berner, Jeanne-Marie; Myklebost, Ola; Bjerkehagen, Bodil; Meza-Zepeda, Leonardo A

    2018-01-01

    Nucleic acid material of adequate quality is crucial for successful high-throughput sequencing (HTS) analysis. DNA and RNA isolated from archival FFPE material are frequently degraded and not readily amplifiable due to chemical damage introduced during fixation. To identify optimal nucleic acid extraction kits, DNA and RNA quantity, quality and performance in HTS applications were evaluated. DNA and RNA were isolated from five sarcoma archival FFPE blocks, using eight extraction protocols from seven kits from three different commercial vendors. For DNA extraction, the truXTRAC FFPE DNA kit from Covaris gave higher yields and better amplifiable DNA, but all protocols gave comparable HTS library yields using Agilent SureSelect XT and performed well in downstream variant calling. For RNA extraction, all protocols gave comparable yields and amplifiable RNA. However, for fusion gene detection using the Archer FusionPlex Sarcoma Assay, the truXTRAC FFPE RNA kit from Covaris and Agencourt FormaPure kit from Beckman Coulter showed the highest percentage of unique read-pairs, providing higher complexity of HTS data and more frequent detection of recurrent fusion genes. truXTRAC simultaneous DNA and RNA extraction gave similar outputs as individual protocols. These findings show that although successful HTS libraries could be generated in most cases, the different protocols gave variable quantity and quality for FFPE nucleic acid extraction. Selecting the optimal procedure is highly valuable and may generate results in borderline quality specimens.

  4. Targeted next generation sequencing of mucosal melanomas identifies frequent NF1 and RAS mutations.

    PubMed

    Cosgarea, Ioana; Ugurel, Selma; Sucker, Antje; Livingstone, Elisabeth; Zimmer, Lisa; Ziemer, Mirjana; Utikal, Jochen; Mohr, Peter; Pfeiffer, Christiane; Pföhler, Claudia; Hillen, Uwe; Horn, Susanne; Schadendorf, Dirk; Griewank, Klaus G; Roesch, Alexander

    2017-06-20

    Mucosal melanoma represents ~1% of all melanomas, frequently having a poor prognosis due to diagnosis at a late stage of disease. Mucosal melanoma differs from cutaneous melanoma not only in terms of poorer clinical outcome but also on the molecular level having e.g. less BRAF and more frequent KIT mutations than cutaneous melanomas. For the majority of mucosal melanomas oncogenic driver mutations remain unknown. In our study, 75 tumor tissues from patients diagnosed with mucosal melanoma were analyzed, applying a targeted next generation sequencing panel covering 29 known recurrently mutated genes in melanoma. NF1 and RAS mutations were identified as the most frequently mutated genes occurring in 18.3% and 16.9% of samples, respectively. Mutations in BRAF were identified in 8.4% and KIT in 7.0% of tumor samples. Our study identifies NF1 as the most frequently occurring driver mutation in mucosal melanoma. RAS alterations, consisting of NRAS and KRAS mutations, were the second most frequent mutation type. BRAF and KIT mutations were rare with frequencies below 10% each. Our data indicate that in mucosal melanomas RAS/NF1 alterations are frequent, implying a significant pathogenetic role for MAPK and potentially PI3K pathway activation in these tumors.

  5. Targeted next generation sequencing of mucosal melanomas identifies frequent NF1 and RAS mutations

    PubMed Central

    Cosgarea, Ioana; Ugurel, Selma; Sucker, Antje; Livingstone, Elisabeth; Zimmer, Lisa; Ziemer, Mirjana; Utikal, Jochen; Mohr, Peter; Pfeiffer, Christiane; Pföhler, Claudia; Hillen, Uwe; Horn, Susanne; Schadendorf, Dirk

    2017-01-01

    Purpose Mucosal melanoma represents ~1% of all melanomas, frequently having a poor prognosis due to diagnosis at a late stage of disease. Mucosal melanoma differs from cutaneous melanoma not only in terms of poorer clinical outcome but also on the molecular level having e.g. less BRAF and more frequent KIT mutations than cutaneous melanomas. For the majority of mucosal melanomas oncogenic driver mutations remain unknown. Experimental Design and Results In our study, 75 tumor tissues from patients diagnosed with mucosal melanoma were analyzed, applying a targeted next generation sequencing panel covering 29 known recurrently mutated genes in melanoma. NF1 and RAS mutations were identified as the most frequently mutated genes occurring in 18.3% and 16.9% of samples, respectively. Mutations in BRAF were identified in 8.4% and KIT in 7.0% of tumor samples. Conclusions Our study identifies NF1 as the most frequently occurring driver mutation in mucosal melanoma. RAS alterations, consisting of NRAS and KRAS mutations, were the second most frequent mutation type. BRAF and KIT mutations were rare with frequencies below 10% each. Our data indicate that in mucosal melanomas RAS/NF1 alterations are frequent, implying a significant pathogenetic role for MAPK and potentially PI3K pathway activation in these tumors. PMID:28380455

  6. Multicentre evaluation of a direct agglutination test prototype kit (DAT-LPC) for diagnosis of visceral leishmaniasis.

    PubMed

    Oliveira, E; Oliveira, D; Cardoso, F A; Barbosa, J R; Marcelino, A P; Dutra, T; Araujo, T; Fernandes, L; Duque, D; Rabello, A

    2017-12-01

    In this study, we assessed the sensitivity, specificity, and diagnostic accuracy of a previously developed direct agglutination test (DAT) using a freeze-dried antigen derived from Leishmania infantum promastigotes and composed in a prototype kit for visceral leishmaniasis (VL) diagnosis, named DAT-LPC. To evaluate DAT-LPC reproducibility, the kit was used to analyse 207 serum samples from VL patients and 80 serum samples from patients with other parasitic infections or healthy subjects in four laboratories from different public health institutions in Brazil. DAT-LPC showed sensitivity between 96·2 and 99·5% (P = 0·14), specificity ranging from 96·2 to 97·5% (P = 0·95), and diagnostic accuracy ranging from 96·5 to 99% (P = 0·34). The inter-laboratory reproducibility of qualitative results was classified as excellent (κ index: 0·94-0·97). The reproducibility of the end-titre results in relation to the reference laboratory, ranged from 31 to 85%. These results demonstrate an excellent performance of the DAT-LPC, and validate it for the diagnosis of VL that could replace the immunofluorescent antibody test as the routine diagnostic test in the Brazilian public health system.

  7. Multigen-2 Pre-Flight Testing: Science Testing Unit (STU) and Stowage Conditions

    NASA Astrophysics Data System (ADS)

    Kittang, A.-I.; Kvaloy, B.; Berg, C.; Rakvaag, G.; Iversen, T.-H.

    2008-06-01

    The Multigen-2 experiment Science Testing Unit (STU) proved to be a useful tool in optimizing experiment environment settings for cultivation of Arabidopsis thaliana (Col-0) in the European Modular Cultivation System (EMCS). By using the EMCS Experiment Reference Model (ERM); light, temperature and air flow regimes for optimal growth could be tested. Healthy seedlings were obtained using the STU#2 and STU#3 in the EMCS ERM. It was concluded that the Experiment Container Development Kit (ECDK) is unsuitable for the Multigen-2 testing due to limitation in the ECDK temperature control. The results from the stowage condition tests showed that the selected growth medium (agar) can be used after 3 months at +4°C. The seeds show a germination rate of ≥80% after sterilisation and stowed for 5 months. The Multigen-2 plant samples will be fixed in RNA later and stored at - 80 °C. Three methods with different RNA isolation kits showed that the Qiagen kit (#74904) gave the highest amount and the best quality of Total RNA from RNA Later and frozen samples. The amount of plant material from one cultivation chamber gives two RNA isolations. Each of the isolations gives Total RNA sufficient for at least two microarray analyses.

  8. Development of a mercury detection kit based on melamine-functionalized gold nanoparticles.

    PubMed

    Liu, Guoyan; Ren, Huipeng; Guan, Yuyu; Dai, Ronghua; Chai, Chunyan

    2015-01-01

    A fast and simple mercury detection kit was developed based on melamine-functionalized gold nanoparticles (GNPs). The detection kit contained reagent 1 (GNPs), reagent 2 (melanine), a reaction cuvette with four separated cells, a colorimetric card and a plastic pipette. The GNPs were prepared by a citrate reduction of HAuCl4. A proper amount of melamine was applied to functionalize the GNPs. The complex reaction took place in the present of Hg(2+) in the test samples, leading to the combination of Hg(2+) with the C=N group of melamine located on the surface of the GNPs. This reaction resulted in damage to the stability of colloid gold, and the aggregation of GNPs occurred. Different color changes (from claret-red to lilac, purple and plum) were displayed with different concentrations of Hg(2+) in the test samples. It was very easy and convenient to determine the amount of mercury ion by the naked eye. The advantages of this methodology are listed as follows: a short detecting time (within 10 min), a high specificity (no significant interference was indicated upon adding a certain amount of Cu(2+), Pb(2+), Zn(2+), Mg(2+), Cd(2+) and Fe(2+)), high sensitivity with a detection limit of 0.01 mg L(-1) , easy operation and practical on-site use.

  9. An rK28-Based Immunoenzymatic Assay for the Diagnosis of Canine Visceral Leishmaniasis in Latin America

    PubMed Central

    Lauricella, Marta Alicia; Maidana, Cristina Graciela; Frias, Victoria Fragueiro; Romagosa, Carlo M.; Negri, Vanesa; Benedetti, Ruben; Sinagra, Angel J.; Luna, Concepcion; Tartaglino, Lilian; Laucella, Susana; Reed, Steven G.; Riarte, Adelina R.

    2016-01-01

    Direct observation of Leishmania parasites in tissue aspirates has shown low sensitivity for the detection of canine visceral leishmaniasis (VL). Therefore in the last quarter century immunoenzymatic tests have been developed to improve diagnosis. The purpose of this study was to develop a fast recombinant K28 antigen, naked-eye qualitative enzyme-linked immunosorbent assay (VL Ql-ELISA) and a quantitative version (VL Qt-ELISA), and to display it in a kit format, whose cutoff value (0.156) was selected as the most adequate one to differentiate reactive from nonreactive samples. Considering 167 cases and 300 controls, sensitivity was 91% for both assays and specificity was 100% and 98.7% in Ql-ELISA and Qt-ELISA, respectively. Positive predictive values were 100% and 97.4% for Ql-ELISA and Qt-ELISA, respectively, and negative predictive values were 95.2% for both ELISAs. Reagent stability, reliability studies, including periodic repetitions and retest of samples, cutoff selection, and comparison of rK28 ELISAs with rK39 immunochromatographic test, were the international criteria that supported the quality in both kits. The performance of both ELISA kits in this work confirmed their validity and emphasized their usefulness for low-to-medium complexity laboratories. PMID:27162270

  10. Reported fire safety and first-aid amenities in Airbnb venues in 16 American cities.

    PubMed

    Kennedy, Hudson R; Jones, Vanya C; Gielen, Andrea

    2018-05-07

    Airbnb helps hosts rent all or part of their home to guests as an alternative to traditional hospitality settings. Airbnb venues are not uniformly regulated across the USA. This study quantified the reported prevalence of fire safety and first-aid amenities in Airbnb venues in the USA. The sample includes 120 691 venues in 16 US cities. Proportions of host-reported smoke and carbon monoxide (CO) detectors, fire extinguishers and first-aid kits were calculated. The proportion of venues that reportedly contained amenities are as follows: smoke detectors 80% (n=96 087), CO detectors 57.5% (n=69 346), fire extinguishers 42% (n=50 884) and first-aid kits 36% (n=43 497). Among this sample of Airbnb venues, safety deficiencies were noted. While most venues had smoke alarms, approximately 1/2 had CO alarms and less than 1/2 reported having a fire extinguishers or first-aid kits. Local and state governments or Airbnb must implement regulations compliant with current National Fire Protection Association fire safety standards. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Highly sensitive immunoassay of anti-cyclic citrullinated peptide marker using surface-enhanced Raman scattering detection

    NASA Astrophysics Data System (ADS)

    Chon, H.; Lee, S.; Wang, R.; Bang, S.-Y.; Lee, H.-S.; Bae, S.-C.; Hong, S. H.; Yoon, Y. H.; Lim, D.; Choo, J.

    2015-07-01

    We report a highly sensitive anti-cyclic citrullinated peptide (anti-CCP) detection method for early diagnosis of rheumatoid arthritis (RA) using surface-enhanced Raman scattering (SERS)-based immunoassay. Herein, cyclic citrullinated peptide (CCP)-conjugated magnetic beads and anti-human IgG-conjugated hollow gold nanospheres (HGNs) were used as substrates and SERS nano-tags, respectively. First, its detection sensitivity was evaluated using anti-CCP standard solutions. Then quantitative anti-CCP levels, determined by the SERS-based assay, were compared with those obtained from three commercially available anti-CCP assay kits (Immunoscan CCPlus, ImmunnLisa™ CCP and BioPlex™ 2200) to assess its potential utility as a clinical tool. Finally, clinical samples from 20 RA patients were investigated using them. In the SERS-based assay, the anti-CCP level in human serum was successfully determined by monitoring the characteristic Raman peak intensity of SERS nano-tags. The diagnostic performance of our SERS-based immunoassay for clinical samples shows a good agreement with those measured by three commercial anti-CCP kits. In addition, our SERS-based assay results are more consistent in the low concentration range (0-25 U/mL) than those achieved by the commercial kits. Accordingly, it is estimated that the SERS-based assay is a potentially useful diagnostic tool for early diagnosis of RA.

  12. Performance of a New HPV Cervi-Collect Collection and Transportation Kit

    PubMed Central

    Chernesky, M.; Huang, S.; Jang, D.; Erickson, B.; Salituro, J.; Engel, H.; Gilchrist, J.; Neuscheler, P.; Mak, W. B.; Abravaya, K.

    2012-01-01

    Background. Liquid-based Pap (L-Pap) media are used for Pap and human papillomavirus (HPV) testing. Objectives. To compare RealTime High Risk (HR) HPV testing of a new collection kit (Cervi-Collect) and PreservCyt L-Pap specimens. To determine ease of use and safety of Cervi-Collect. Methods. L-Pap samples (n = 203) were tested with HC2 and RealTime HR HPV and Cervi-Collect with RealTime HR HPV. Discordant samples were genotyped. Results. L-Pap and Cervi-Collect specimens tested by RealTime HR HPV showed 93.1% agreement (Kappa 0.86). RealTime HR HPV and HC2 on L-Pap had 90.3% agreement (Kappa 0.80). RealTime HR HPV on Cervi-Collect and HC2 on L-Pap showed 88.2% agreement (Kappa 0.76). Sixteen of 21 samples which were HC2 negative and RealTime HR HPV positive on L-Pap or Cervi-Collect contained HR HPV genotypes. Eleven healthcare collectors were in strong agreement on a usability and safety questionnaire. Conclusion. Cervi-Collect samples were easy to collect and showed strong agreement with L-Pap samples tested with RealTime HR HPV or HC2. PMID:22174716

  13. Ancestry prediction in Singapore population samples using the Illumina ForenSeq kit.

    PubMed

    Ramani, Anantharaman; Wong, Yongxun; Tan, Si Zhen; Shue, Bing Hong; Syn, Christopher

    2017-11-01

    The ability to predict bio-geographic ancestry can be valuable to generate investigative leads towards solving crimes. Ancestry informative marker (AIM) sets include large numbers of SNPs to predict an ancestral population. Massively parallel sequencing has enabled forensic laboratories to genotype a large number of such markers in a single assay. Illumina's ForenSeq DNA Signature Kit includes the ancestry informative SNPs reported by Kidd et al. In this study, the ancestry prediction capabilities of the ForenSeq kit through sequencing on the MiSeq FGx were evaluated in 1030 unrelated Singapore population samples of Chinese, Malay and Indian origin. A total of 59 ancestry SNPs and phenotypic SNPs with AIM properties were selected. The bio-geographic ancestry of the 1030 samples, as predicted by Illumina's ForenSeq Universal Analysis Software (UAS), was determined. 712 of the genotyped samples were used as a training sample set for the generation of an ancestry prediction model using STRUCTURE and Snipper. The performance of the prediction model was tested by both methods with the remaining 318 samples. Ancestry prediction in UAS was able to correctly classify the Singapore Chinese as part of the East Asian cluster, while Indians clustered with Ad-mixed Americans and Malays clustered in-between these two reference populations. Principal component analyses showed that the 59 SNPs were only able to account for 26% of the variation between the Singapore sub-populations. Their discriminatory potential was also found to be lower (G ST =0.085) than that reported in ALFRED (F ST =0.357). The Snipper algorithm was able to correctly predict bio-geographic ancestry in 91% of Chinese and Indian, and 88% of Malay individuals, while the success rates for the STRUCTURE algorithm were 94% in Chinese, 80% in Malay, and 91% in Indian individuals. Both these algorithms were able to provide admixture proportions when present. Ancestry prediction accuracy (in terms of likelihood ratio) was generally high in the absence of admixture. Misclassification occurred in admixed individuals, who were likely offspring of inter-ethnic marriages, and hence whose self-reported bio-geographic ancestries were dependent on that of their fathers, and in individuals of minority sub-populations with inter-ethnic beliefs. The ancestry prediction capabilities of the 59 SNPs on the ForenSeq kit were reasonably effective in differentiating the Singapore Chinese, Malay and Indian sub-populations, and will be of use for investigative purposes. However, there is potential for more accurate prediction through the evaluation of other AIM sets. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Dried venous blood samples for the detection and quantification of measles IgG using a commercial enzyme immunoassay.

    PubMed Central

    Riddell, Michaela A.; Byrnes, Graham B.; Leydon, Jennie A.; Kelly, Heath A.

    2003-01-01

    OBJECTIVES: To determine whether samples of dried venous blood (DVB) were an acceptable alternative to serum for detecting measles-specific IgG in a commercial enzyme immunoassay. METHODS: Paired samples of serum and DVB were collected from 98 suspected cases of measles and 1153 schoolchildren in Victoria, Australia. All samples were tested using the Dade Behring Enzygnost Anti-Measles-Virus/IgG immunoassay. DVB samples were eluted using either the sample buffer provided with the kit or 5% dry milk powder in phosphate-buffered saline-Tween 20. FINDINGS: DVB samples eluted by sample buffer showed significantly better linear correlation to the serum samples than did DVB samples eluted in 5% dry milk in phosphate-buffered saline-Tween 20. To improve the comparability of serum and DVB samples an adjustment factor of 1.28 was applied to the optical density (OD) values of DVB. This adjustment also enabled quantification of the titre of measles IgG in mIU/ml directly from the OD value using the alpha calculation as specified by the kit protocol. For DVB samples stored for less than six months at 4 degrees C, the assay showed an overall sensitivity of 98.4% and a specificity of 97.2% compared with the results of serum testing. CONCLUSION: These results illustrate the potential for DVB samples to be widely used with the Dade Behring enzyme immunoassay system for determining the immunity of the individual and the population to the measles virus. PMID:14758429

  15. Next-Generation Sequencing-based genomic profiling of brain metastases of primary ovarian cancer identifies high number of BRCA-mutations.

    PubMed

    Balendran, S; Liebmann-Reindl, S; Berghoff, A S; Reischer, T; Popitsch, N; Geier, C B; Kenner, L; Birner, P; Streubel, B; Preusser, M

    2017-07-01

    Ovarian cancer represents the most common gynaecological malignancy and has the highest mortality of all female reproductive cancers. It has a rare predilection to develop brain metastases (BM). In this study, we evaluated the mutational profile of ovarian cancer metastases through Next-Generation Sequencing (NGS) with the aim of identifying potential clinically actionable genetic alterations with options for small molecule targeted therapy. Library preparation was conducted using Illumina TruSight Rapid Capture Kit in combination with a cancer specific enrichment kit covering 94 genes. BRCA-mutations were confirmed by using TruSeq Custom Amplicon Low Input Kit in combination with a custom-designed BRCA gene panel. In our cohort all eight sequenced BM samples exhibited a multitude of variant alterations, each with unique molecular profiles. The 37 identified variants were distributed over 22 cancer-related genes (23.4%). The number of mutated genes per sample ranged from 3 to 7 with a median of 4.5. The most commonly altered genes were BRCA1/2, TP53, and ATM. In total, 7 out of 8 samples revealed either a BRCA1 or a BRCA2 pathogenic mutation. Furthermore, all eight BM samples showed mutations in at least one DNA repair gene. Our NGS study of BM of ovarian carcinoma revealed a significant number of BRCA-mutations beside TP53, ATM and CHEK2 mutations. These findings strongly suggest the implication of BRCA and DNA repair malfunction in ovarian cancer metastasizing to the brain. Based on these findings, pharmacological PARP inhibition could be one potential targeted therapeutic for brain metastatic ovarian cancer patients.

  16. A new LAMP-based assay for the molecular diagnosis of toxoplasmosis: comparison with a proficient PCR assay.

    PubMed

    Varlet-Marie, Emmanuelle; Sterkers, Yvon; Perrotte, Marina; Bastien, Patrick

    2018-05-01

    Toxoplasmosis is generally a benign infection caused by the protozoan parasite Toxoplasma gondii but can have severe consequences in fetuses of mothers infected during pregnancy (congenital toxoplasmosis) and immunocompromised individuals. PCR-based diagnostic tests have become crucial for its diagnosis. However, this molecular diagnosis essentially relies upon laboratory-developed methods and suffers from a lack of standardization, leading to great variation in methods and performance among laboratories. With the need for accreditation of clinical microbiological laboratories, the use of commercial PCR kits has become an attractive alternative; but thorough evaluation of newly commercialized kits by proficient groups is necessary before any recommendation can be made to parasitology laboratories by health authorities or learned societies. Here, we compared the performance of an original commercial method, the Iam TOXO Q-LAMP (DiaSorin®), using Loop-mediated isothermal amplification (LAMP) technology, with our reference laboratory-developed method using real-time PCR. The kit was first tested using amniotic fluid (AF) and plasma samples (either negative or spiked with live T. gondii tachyzoites at different concentrations (from 7 to 10 5  tachyzoites/mL)). It was then assessed using a cohort of 11 AF, five placental and 32 blood clinical samples preserved at -20 °C. For the processing of placental/blood samples, a pretreatment step was used, which did not strictly follow the manufacturer's recommendations. The practical ease of use and compliance with good laboratory practices were also evaluated. Although the LAMP assay was less sensitive than the laboratory-developed method at very low parasite concentrations (0.1 T. gondii genome equivalents/mL), the two methods yielded identical results qualitatively and, in some instances, quantitatively, particularly for AF samples. Copyright © 2018. Published by Elsevier Ltd.

  17. Performance Characteristics of a New Consensus Commercial Kit for Hepatitis D Virus RNA Viral Load Quantification.

    PubMed

    Le Gal, Frédéric; Dziri, Samira; Gerber, Athenaïs; Alloui, Chakib; Ben Abdesselam, Zahia; Roulot, Dominique; Brichler, Ségolène; Gordien, Emmanuel

    2017-02-01

    Hepatitis D virus (HDV) is responsible for fulminant hepatitis and liver failure and accelerates evolution toward cirrhosis and hepatocellular carcinoma in hepatitis B virus (HBV)-infected patients. To date, treatment relies upon long-term administration of pegylated alpha-interferon with a sustained virological response in 30% of the patients. Very recently, new, promising anti-HDV therapies have been developed and are already being used in clinical trials. HDV RNA viral load (HDVL) monitoring must be an integral part of the management of the infected patients. However, HDV genus is characterized by a high genetic variability into eight genotypes (HDV-1 to -8), and most available in-house or commercial assays are useful for only a limited subset of genotypes. Results of a comparison of the performance of a new kit for HDVL quantification with the consensus in-house assay of the French National Reference Laboratory for HDV developed in 2005 are reported here. A total of 611 clinical samples of all HDV genotypes with various HDVL values, including several consecutive samples over several years from 36 patients, were studied. A specificity, sensitivity, and reproducibility evaluation was conducted using HDV-positive clinical samples, hepatitis A, B, C and E (HAV, HBV, HCV, and HEV, respectively) and HIV mono-infected samples, and the WHO HDV RNA international standard. Overall results were strictly comparable between the two assays (median difference, 0.07 log IU/ml), with high diagnosis precision and capacity. In summary, this new kit showed high performance in detection/quantification of HDVL, regardless of the genotype of the infecting strain used, and seems to be a suitable tool for patient management. Copyright © 2017 American Society for Microbiology.

  18. First Evaluation of Glucose-6-Phosphate Dehydrogenase (G6PD) Deficiency in Vivax Malaria Endemic Regions in the Republic of Korea

    PubMed Central

    Goo, Youn-Kyoung; Ji, So-Young; Shin, Hyun-Il; Moon, Jun-Hye; Cho, Shin-Hyung; Lee, Won-Ja; Kim, Jung-Yeon

    2014-01-01

    Background Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common human enzyme defect and affects more than 400 million people worldwide. This deficiency is believed to protect against malaria because its global distribution is similar. However, this genetic disorder may be associated with potential hemolytic anemia after treatment with anti-malarials, primaquine or other 8-aminoquinolines. Although primaquine is used for malaria prevention, no study has previously investigated the prevalence of G6PD variants and G6PD deficiency in the Republic of Korea (ROK). Methods Two commercialized test kits (Trinity G-6-PDH and CareStart G6PD test) were used for G6PD deficiency screening. The seven common G6PD variants were investigated by DiaPlexC kit in blood samples obtained living in vivax malaria endemic regions in the ROK. Results Of 1,044 blood samples tested using the CareStart G6PD test, none were positive for G6PD deficiency. However, a slightly elevated level of G6PD activity was observed in 14 of 1,031 samples tested with the Trinity G-6-PDH test. Forty-nine of the 298 samples with non-specific amplification by DiaPlexC kit were confirmed by sequencing to be negative for the G6PD variants. Conclusions No G6PD deficiency was observed using phenotypic- or genetic-based tests in individuals residing in vivax malaria endemic regions in the ROK. Because massive chemoprophylaxis using primaquine has been performed in the ROK military to kill hypnozoites responsible for relapse and latent stage vivax malaria, further regular monitoring is essential for the safe administration of primaquine. PMID:24853873

  19. First evaluation of glucose-6-phosphate dehydrogenase (G6PD) deficiency in vivax malaria endemic regions in the Republic of Korea.

    PubMed

    Goo, Youn-Kyoung; Ji, So-Young; Shin, Hyun-Il; Moon, Jun-Hye; Cho, Shin-Hyung; Lee, Won-Ja; Kim, Jung-Yeon

    2014-01-01

    Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common human enzyme defect and affects more than 400 million people worldwide. This deficiency is believed to protect against malaria because its global distribution is similar. However, this genetic disorder may be associated with potential hemolytic anemia after treatment with anti-malarials, primaquine or other 8-aminoquinolines. Although primaquine is used for malaria prevention, no study has previously investigated the prevalence of G6PD variants and G6PD deficiency in the Republic of Korea (ROK). Two commercialized test kits (Trinity G-6-PDH and CareStart G6PD test) were used for G6PD deficiency screening. The seven common G6PD variants were investigated by DiaPlexC kit in blood samples obtained living in vivax malaria endemic regions in the ROK. Of 1,044 blood samples tested using the CareStart G6PD test, none were positive for G6PD deficiency. However, a slightly elevated level of G6PD activity was observed in 14 of 1,031 samples tested with the Trinity G-6-PDH test. Forty-nine of the 298 samples with non-specific amplification by DiaPlexC kit were confirmed by sequencing to be negative for the G6PD variants. No G6PD deficiency was observed using phenotypic- or genetic-based tests in individuals residing in vivax malaria endemic regions in the ROK. Because massive chemoprophylaxis using primaquine has been performed in the ROK military to kill hypnozoites responsible for relapse and latent stage vivax malaria, further regular monitoring is essential for the safe administration of primaquine.

  20. CSF biomarker variability in the Alzheimer’s Association quality control program

    PubMed Central

    Mattsson, Niklas; Andreasson, Ulf; Persson, Staffan; Carrillo, Maria C.; Collins, Steven; Chalbot, Sonia; Cutler, Neal; Dufour-Rainfray, Diane; Fagan, Anne M.; Heegaard, Niels H. H.; Hsiung, Ging-Yuek Robin; Hyman, Bradley; Iqbal, Khalid; Lachno, D. Richard; Lleó, Alberto; Lewczuk, Piotr; Molinuevo, José L.; Parchi, Piero; Regeniter, Axel; Rissman, Robert; Rosenmann, Hanna; Sancesario, Giuseppe; Schröder, Johannes; Shaw, Leslie M.; Teunissen, Charlotte E.; Trojanowski, John Q.; Vanderstichele, Hugo; Vandijck, Manu; Verbeek, Marcel M.; Zetterberg, Henrik; Blennow, Kaj; Käser, Stephan A.

    2013-01-01

    Background The cerebrospinal fluid (CSF) biomarkers amyloid beta 1–42, total tau, and phosphorylated tau are used increasingly for Alzheimer’s disease (AD) research and patient management. However, there are large variations in biomarker measurements among and within laboratories. Methods Data from the first nine rounds of the Alzheimer’s Association quality control program was used to define the extent and sources of analytical variability. In each round, three CSF samples prepared at the Clinical Neurochemistry Laboratory (Mölndal, Sweden) were analyzed by single-analyte enzyme-linked immunosorbent assay (ELISA), a multiplexing xMAP assay, or an immunoassay with electrochemoluminescence detection. Results A total of 84 laboratories participated. Coefficients of variation (CVs) between laboratories were around 20% to 30%; within-run CVs, less than 5% to 10%; and longitudinal within-laboratory CVs, 5% to 19%. Interestingly, longitudinal within-laboratory CV differed between biomarkers at individual laboratories, suggesting that a component of it was assay dependent. Variability between kit lots and between laboratories both had a major influence on amyloid beta 1–42 measurements, but for total tau and phosphorylated tau, between-kit lot effects were much less than between-laboratory effects. Despite the measurement variability, the between-laboratory consistency in classification of samples (using prehoc-derived cutoffs for AD) was high (>90% in 15 of 18 samples for ELISA and in 12 of 18 samples for xMAP). Conclusions The overall variability remains too high to allow assignment of universal biomarker cutoff values for a specific intended use. Each laboratory must ensure longitudinal stability in its measurements and use internally qualified cutoff levels. Further standardization of laboratory procedures and improvement of kit performance will likely increase the usefulness of CSF AD biomarkers for researchers and clinicians. PMID:23622690

  1. Detection of EGFR Variants in Plasma: A Multilaboratory Comparison of the cobas EGFR Mutation Test v2 in Europe.

    PubMed

    Keppens, Cleo; Palma, John F; Das, Partha M; Scudder, Sidney; Wen, Wei; Normanno, Nicola; Van Krieken, J Han; Sacco, Alessandra; Fenizia, Francesca; de Castro, David Gonzalez; Hönigschnabl, Selma; Kern, Izidor; Lopez-Rios, Fernando; Lozano, Maria D; Marchetti, Antonio; Halfon, Philippe; Schuuring, Ed; Setinek, Ulrike; Sorensen, Boe; Taniere, Phillipe; Tiemann, Markus; Vosmikova, Hana; Dequeker, Elisabeth M C

    2018-04-25

    Molecular testing of EGFR is required to predict the response likelihood to targeted therapy in non-small-cell lung cancer. Analysis of circulating tumor DNA in plasma may complement limitations of tumor tissue. This study evaluated the interlaboratory performance and reproducibility of the cobas EGFR Mutation Test v2 to detect EGFR variants in plasma. Fourteen laboratories received two identical panels of 27 single-blinded plasma samples. Samples were wild-type or spiked with plasmid DNA to contain seven common EGFR variants at six predefined concentrations from 50 to 5000 copies per mL. The circulating tumor DNA was extracted by the cobas cfDNA Sample Preparation kit, followed by duplicate analysis with the EGFRv2 kit (Roche Molecular Systems, Pleasanton, CA). Lowest sensitivities were obtained for the c.2156G>C p.(Gly719Ala) and c.2573T>G p.(Leu858Arg) variants for the lowest target copies. For all other variants, sensitivities varied between 96.3% and 100.0%. Specificities were all 98.8% to 100.0%. Coefficients of variation indicated good intra and interlaboratory repeatability and reproducibility, but increased for decreasing concentrations. Prediction models revealed a significant correlation for all variants between the pre-defined copy number and the observed semiquantitative index values which reflects the samples' plasma mutation load. This study demonstrates an overall robust performance of the EGFRv2 kit in plasma. Prediction models may be applied to estimate the plasma mutation load for diagnostic or research purposes. Copyright © 2018 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  2. Delivery of chlamydia screening to young women requesting emergency hormonal contraception at pharmacies in Manchester, UK: a prospective study

    PubMed Central

    Brabin, Loretta; Thomas, Grace; Hopkins, Mark; O'Brien, Karen; Roberts, Stephen A

    2009-01-01

    Background More women are requesting Emergency Hormonal Contraception (EHC) at pharmacies where screening for Chlamydia trachomatis is not routinely offered. The objective of this study was to assess the uptake of free postal chlamydia screening by women under 25 years who requested EHC at pharmacies in Manchester, UK. Methods Six Primary Care Trusts (PCTs) that had contracted with pharmacies to provide free EHC, requested the largest EHC providers (≥ 40 doses annually) to also offer these clients a coded chlamydia home testing kit. Pharmacies kept records of the ages and numbers of women who accepted or refused chlamydia kits. Women sent urine samples directly to the laboratory for testing and positive cases were notified. Audit data on EHC coverage was obtained from PCTs to assess the proportion of clients eligible for screening and to verify the uptake rate. Results 33 pharmacies participated. Audit data for 131 pharmacy months indicated that only 24.8% (675/2718) of women provided EHC were also offered chlamydia screening. Based on tracking forms provided by pharmacies for the whole of the study, 1348/2904 EHC clients (46.4%) who had been offered screening accepted a screening kit. 264 (17.6%) of those who accepted a kit returned a sample, of whom 24 (9.1%) were chlamydia-positive. There was an increase in chlamydia positivity with age (OR: 1.2 per year; 1.04 to 1.44; p = 0.015). Conclusion Chlamydia screening for EHC pharmacy clients is warranted but failure of pharmacists to target all EHC clients represented a missed opportunity for treating a well defined high-risk group. PMID:19323804

  3. Selective gene amplification to detect the T790M mutation in plasma from patients with advanced non-small cell lung cancer (NSCLC) who have developed epidermal growth factor receptor tyrosine kinase inhibitor (EGFR-TKI) resistance.

    PubMed

    Nishikawa, Shingo; Kimura, Hideharu; Koba, Hayato; Yoneda, Taro; Watanabe, Satoshi; Sakai, Tamami; Hara, Johsuke; Sone, Takashi; Kasahara, Kazuo; Nakao, Shinji

    2018-03-01

    The epidermal growth factor receptor (EGFR) T790M mutation is associated with resistance to EGFR tyrosine kinase inhibitors (EGFR-TKIs) in non-small cell lung cancer (NSCLC). However, tissues for the genotyping of the EGFR T790M mutation can be difficult to obtain in a clinical setting. The aims of this study were to evaluate a blood-based, non-invasive approach to detecting the EGFR T790M mutation in advanced NSCLC patients using the PointMan™ EGFR DNA enrichment kit, which is a novel method for the selective amplification of specific genotype sequences. Blood samples were collected from NSCLC patients who had activating EGFR mutations and who were resistant to EGFR-TKI treatment. Using cell-free DNA (cfDNA) from plasma, EGFR T790M mutations were amplified using the PointMan™ enrichment kit, and all the reaction products were confirmed using direct sequencing. The concentrations of plasma DNA were then determined using quantitative real-time PCR. Nineteen patients were enrolled, and 12 patients (63.2%) were found to contain EGFR T790M mutations in their cfDNA, as detected by the kit. T790M mutations were detected in tumor tissues in 12 cases, and 11 of these cases (91.7%) also exhibited the T790M mutation in cfDNA samples. The concentrations of cfDNA were similar between patients with the T790M mutation and those without the mutation. The PointMan™ kit provides a useful method for determining the EGFR T790M mutation status in cfDNA.

  4. Validation of a commercial kit aimed to the detection of pathogenic anisakid nematodes in fish products.

    PubMed

    Cavallero, Serena; Bruno, Alessandro; Arletti, Enrico; Caffara, Monica; Fioravanti, Maria Letizia; Costa, Antonella; Cammilleri, Gaetano; Graci, Stefania; Ferrantelli, Vincenzo; D'Amelio, Stefano

    2017-09-18

    Anisakids are parasitic nematodes responsible for a zoonosis that occurs following the ingestion of fish and fish products infected with larvae belonging to the genera Anisakis and Pseudoterranova. Rarely Contracaecum is found in association with gastric/intestinal illness, while Hysterothylacium is commonly considered not pathogenic. Although Real Time PCR assays have been recently used with the aim to detect and quantify these parasites in food products, methods applied did not undergo through extensive validation process, a feature highly desirable or mandatory in the case of testing laboratories accredited for the ISO EN 17025:2005. Here, a comprehensive study has been performed to validate a commercial kit based on multiplex real time PCR for the qualitative detection of Anisakis and Pseudoterranova. Inclusivity/exclusivity trials were carried out on DNA from species of the genera Anisakis, Pseudoterranova, Contracaecum, Hysterothylacium and Ascaris, on fish intentionally contaminated with Anisakis spp. and Pseudoterranova spp. and on marine organisms as fish, crustacean and squid to test the commercial kit on a large sample. The assay gave positive amplification for several Anisakis and Pseudoterranova species, while providing no signal for the members of the remaining genera. Each sample was correctly assigned either to Anisakis or Pseudoterranova, thus indicating that no cross-reaction occurred. The LOD was determined using two independent standard curves. Robustness was assayed by using two different thermocyclers in three distinct laboratories with different operators. The establishment of a validation dossier will permit the use of the commercial kit for the detection of Anisakis and Pseudoterranova DNA in fish and fish products intended for human consumption by public or private laboratories, following the requirements regarding the quality assurance processes described in the ISO EN 17025:2005. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Radotinib induces high cytotoxicity in c-KIT positive acute myeloid leukemia cells.

    PubMed

    Heo, Sook-Kyoung; Noh, Eui-Kyu; Kim, Jeong Yi; Jo, Jae-Cheol; Choi, Yunsuk; Koh, SuJin; Baek, Jin Ho; Min, Young Joo; Kim, Hawk

    2017-06-05

    Previously, we reported that radotinib, a BCR-ABL1 tyrosine kinase inhibitor, induced cytotoxicity in acute myeloid leukemia (AML) cells. However, the effects of radotinib in the subpopulation of c-KIT-positive AML cells were unclear. We observed that low-concentration radotinib had more potent cytotoxicity in c-KIT-positive cells than c-KIT-negative cells from AML patients. To address this issue, cell lines with high c-KIT expression, HEL92.1.7, and moderate c-KIT expression, H209, were selected. HEL92.1.7 cells were grouped into intermediate and high c-KIT expression populations. The cytotoxicity of radotinib against the HEL92.1.7 cell population with intermediate c-KIT expression was not different from that of the population with high c-KIT expression. When H209 cells were grouped into c-KIT expression-negative and c-KIT expression-positive populations, radotinib induced cytotoxicity in the c-KIT-positive population, but not the c-KIT-negative population. Thus, radotinib induces cytotoxicity in c-KIT-positive cells, regardless of the c-KIT expression intensity. Therefore, radotinib induces significant cytotoxicity in c-KIT-positive AML cells, suggesting that radotinib is a potential target agent for the treatment of c-KIT-positive malignancies including AML. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Techni-kits and Techni-kit Building Systems

    NASA Technical Reports Server (NTRS)

    Callender, E. D.; Hartsough, C.; Morris, R. V.; Yamamoto, Y.

    1985-01-01

    Techni-kits consists of theories, methods, standards and computer based tools that assist in design of information-intensive systems. Techni-kit "building system" is techni-kit that builds techni-kits.

  7. Home dim light melatonin onsets with measures of compliance in delayed sleep phase disorder.

    PubMed

    Burgess, Helen J; Park, Margaret; Wyatt, James K; Fogg, Louis F

    2016-06-01

    The dim light melatonin onset (DLMO) assists with the diagnosis and treatment of circadian rhythm sleep disorders. Home DLMOs are attractive for cost savings and convenience, but can be confounded by home lighting and sample timing errors. We developed a home saliva collection kit with objective measures of light exposure and sample timing. We report on our first test of the kit in a clinical population. Thirty-two participants with delayed sleep phase disorder (DSPD; 17 women, aged 18-52 years) participated in two back-to-back home and laboratory phase assessments. Most participants (66%) received at least one 30-s epoch of light >50 lux during the home phase assessments, but for only 1.5% of the time. Most participants (56%) collected every saliva sample within 5 min of the scheduled time. Eighty-three per cent of home DLMOs were not affected by light or sampling errors. The home DLMOs occurred, on average, 10.2 min before the laboratory DLMOs, and were correlated highly with the laboratory DLMOs (r = 0.93, P < 0.001). These results indicate that home saliva sampling with objective measures of light exposure and sample timing, can assist in identifying accurate home DLMOs. © 2016 European Sleep Research Society.

  8. A decrease in ubiquitination and resulting prolonged life-span of KIT underlies the KIT overexpression-mediated imatinib resistance of KIT mutation-driven canine mast cell tumor cells.

    PubMed

    Kobayashi, Masato; Kuroki, Shiori; Kurita, Sena; Miyamoto, Ryo; Tani, Hiroyuki; Tamura, Kyoichi; Bonkobara, Makoto

    2017-10-01

    Overexpression of KIT is one of the mechanisms that contributes to imatinib resistance in KIT mutation-driven tumors. Here, the mechanism underlying this overexpression of KIT was investigated using an imatinib-sensitive canine mast cell tumor (MCT) line CoMS, which has an activating mutation in KIT exon 11. A KIT-overexpressing imatinib-resistant subline, rCoMS1, was generated from CoMS cells by their continuous exposure to increasing concentrations of imatinib. Neither a secondary mutation nor upregulated transcription of KIT was detected in rCoMS1 cells. A decrease in KIT ubiquitination, a prolonged KIT life-span, and KIT overexpression were found in rCoMS1 cells. These events were suppressed by withdrawal of imatinib and were re-induced by re‑treatment with imatinib. These findings suggest that imatinib elicited overexpression of KIT via suppression of its ubiquitination. These results also indicated that imatinib-induced overexpression of KIT in rCoMS1 cells was not a permanently acquired feature but was a reversible response of the cells. Moreover, the pan deubiquitinating enzyme inhibitor PR619 prevented imatinib induction of KIT overexpression, suggesting that the imatinib-induced decrease in KIT ubiquitination could be mediated by upregulation and/or activation of deubiquitinating enzyme(s). It may be possible that a similar mechanism of KIT overexpression underlies the acquisition of imatinib resistance in some human tumors that are driven by KIT mutation.

  9. High throughput DNA damage quantification of human tissue with home-based collection device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Costes, Sylvain V.; Tang, Jonathan; Yannone, Steven M.

    Kits, methods and systems for providing a service to provide a subject with information regarding the state of a subject's DNA damage. Collection, processing and analysis of samples are also described.

  10. College Women's Health

    MedlinePlus

    ... the College Women's Social Media Kit! College Women's Social Media Toolkit Use the Social Media Toolkit to share health tips with your campus ... toolkit includes resources for young women including sample social media messages, flyers and blogs posts. NEW Social Media ...

  11. Detection of illicit drugs in impaired driver saliva by a field-usable SERS analyzer

    NASA Astrophysics Data System (ADS)

    Shende, Chetan; Huang, Hermes; Farquharson, Stuart

    2014-05-01

    One of the greatest dangers of drug use is in combination with driving. According to the most recent National Highway Traffic Safety Administration (NHTSA) studies, more than 11% of drivers tested positive for illicit drugs, while 18% of drivers killed in accidents tested positive for illicit, prescription or over-the-counter drugs. Consequently, there is a need for a rapid, noninvasive, roadside drug testing device, similar to the breathalyzers used by law enforcement officials to estimate blood alcohol levels of impaired drivers. In an effort to satisfy this need we have been developing a sampling kit that allows extraction of drugs from 1 mL of saliva and detection by surfaceenhanced Raman spectroscopy using a portable Raman analyzer. Here we describe the development of the sampling kit and present measurements of diazepam at sub μg/mL concentrations measured in ~15 minutes.

  12. Database extraction strategies for low-template evidence.

    PubMed

    Bleka, Øyvind; Dørum, Guro; Haned, Hinda; Gill, Peter

    2014-03-01

    Often in forensic cases, the profile of at least one of the contributors to a DNA evidence sample is unknown and a database search is needed to discover possible perpetrators. In this article we consider two types of search strategies to extract suspects from a database using methods based on probability arguments. The performance of the proposed match scores is demonstrated by carrying out a study of each match score relative to the level of allele drop-out in the crime sample, simulating low-template DNA. The efficiency was measured by random man simulation and we compared the performance using the SGM Plus kit and the ESX 17 kit for the Norwegian population, demonstrating that the latter has greatly enhanced power to discover perpetrators of crime in large national DNA databases. The code for the database extraction strategies will be prepared for release in the R-package forensim. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  13. A solid colorimetric sensor for the analysis of amphetamine-like street samples.

    PubMed

    Argente-García, A; Jornet-Martínez, N; Herráez-Hernández, R; Campíns-Falcó, P

    2016-11-02

    A solid sensor obtained by embedding 1,2-naphthoquinone-4-sulfonate (NQS) into polydimethylsiloxane/tetraethylortosilicate/silicon dioxide nanoparticles composite has been developed to identify and determine amphetamine (AMP), methamphetamine (MAMP), 3,4-methylenedioxymetamphetamine (MDMA) and 3,4-methylenedioxyamphetamine (MDA). The analytes are derivatized inside the composite for 10 min to create a colored product which can be then quantified by measuring the diffuse reflectance or the color intensity after processing the digitalized image. Satisfactory limits of detection (0.002-0.005 g mL -1 ) and relative standard deviations (<10%) have been achieved. The proposed kit has been successfully validated and applied to the analysis of amphetamine-like drugs street samples. The kit allows the in-situ screening of the mentioned illicit drugs owing to its simplicity, rapidity and portability, with excellent sensor stability and at a very low-cost. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Evaluation of six serological ELISA kits available in Italy as screening tests for equine infectious anaemia surveillance.

    PubMed

    Nardini, Roberto; Autorino, Gian Luca; Issel, Charles J; Cook, R Frank; Ricci, Ida; Frontoso, Raffaele; Rosone, Francesca; Scicluna, Maria Teresa

    2017-04-14

    ELISAs are known to have a higher diagnostic sensitivity than the agar gel immunodiffusion (AGID) when employed for serological diagnosis of equine infectious anaemia (EIA). For this purpose, an "in-house" and five commercial ELISAs available in Italy were assessed by the National Reference Centre for EIA for their analytic specificity (Sp); precocity, defined as capability of detecting first antibodies produced during a new infection; precision based on repeatability and reproducibility, estimated from the coefficient of variation (CV); accuracy, estimated from multiple K and relative Sp and sensitivity (Se). Two serum panels, positive for non-equine retroviruses and the most frequent equine viruses, were employed to measure analytic Sp. ELISA precocity was also compared to that of one "in-house" and three commercial AGID kits, employing a panel of sera, collected weekly from horses infected with modified EIA viruses. Precision and accuracy were defined using results of a panel containing positive and negative sera examined in an inter-laboratory trial with the participation of the ten Official Laboratories. Furthermore, a questionnaire was used to assess the appropriateness of each kit for routine use. Analytic Sp was 100%, while the 75th percentile of CVs for positive sera varied from 0.4% to 12.73% for repeatability and from 1.6% to 44.87% for reproducibility. Although CV of the negative serum was constantly high, its outcome was unaltered. Relative Se ranged from 98.2% to 100%, relative Sp was constantly 100% and multiple K ranged from 0.95 to 1. Precocity differed among the assays: three kits detected 4.8% and 42.9% positive samples on 21 days post infection (dpi), all assays detected positive samples on 28 dpi, between 47.6% and 95.2%. Precocity of ELISAs was superior to that of the AGIDs except for two assays. In view of the feedback obtained from the questionnaires, all kits were considered appropriate for routine use. All ELISAs having high Se and precocity are preferable as a screening test in EIA surveillance programmes to the AGID tests examined. These two tests can be incorporated in a serial diagnostic pathway to improve the efficacy of a surveillance plan.

  15. Correlation of KIT and PDGFRA mutational status with clinical benefit in patients with gastrointestinal stromal tumor treated with sunitinib in a worldwide treatment-use trial.

    PubMed

    Reichardt, Peter; Demetri, George D; Gelderblom, Hans; Rutkowski, Piotr; Im, Seock-Ah; Gupta, Sudeep; Kang, Yoon-Koo; Schöffski, Patrick; Schuette, Jochen; Soulières, Denis; Blay, Jean-Yves; Goldstein, David; Fly, Kolette; Huang, Xin; Corsaro, Massimo; Lechuga, Maria Jose; Martini, Jean-Francois; Heinrich, Michael C

    2016-01-15

    Several small studies indicated that the genotype of KIT or platelet-derived growth factor receptor-α (PDGFRA) contributes in part to the level of clinical effectiveness of sunitinib in gastrointestinal stromal tumor (GIST) patients. This study aimed to correlate KIT and PDGFRA mutational status with clinical outcome metrics (progression-free survival [PFS], overall survival [OS], objective response rate [ORR]) in a larger international patient population. This is a non-interventional, retrospective analysis in patients with imatinib-resistant or intolerant GIST who were treated in a worldwide, open-label treatment-use study (Study 1036; NCT00094029) in which sunitinib was administered at a starting dose of 50 mg/day on a 4-week-on, 2-week-off schedule. Molecular status was obtained in local laboratories with tumor samples obtained either pre-imatinib, post-imatinib/pre-sunitinib, or post-sunitinib treatment, and all available data were used in the analyses regardless of collection time. The primary analysis compared PFS in patients with primary KIT exon 11 versus exon 9 mutations (using a 2-sided log-rank test) and secondary analyses compared OS (using the same test) and ORR (using a 2-sided Pearson χ(2) test) in the same molecular subgroups. Of the 1124 sunitinib-treated patients in the treatment-use study, 230 (20%) were included in this analysis, and baseline characteristics were similar between the two study populations. Median PFS was 7.1 months. A significantly better PFS was observed in patients with a primary mutation in KIT exon 9 (n = 42) compared to those with a primary mutation in exon 11 (n = 143; hazard ratio = 0.59; 95 % confidence interval, 0.39-0.89; P = 0.011), with median PFS times of 12.3 and 7.0 months, respectively. Similarly, longer OS and higher ORR were observed in patients with a primary KIT mutation in exon 9 versus exon 11. The data available were limited to investigate the effects of additional KIT or PDGFRA mutations on the efficacy of sunitinib treatment. This large retrospective analysis confirms the prognostic significance of KIT mutation status in patients with GIST. This analysis also confirms the effectiveness of sunitinib as a post-imatinib therapy, regardless of mutational status. NCT01459757.

  16. Comparison of two techniques for removing fiber posts.

    PubMed

    Gesi, A; Magnolfi, S; Goracci, C; Ferrari, M

    2003-09-01

    The purpose of this study was to evaluate the time needed to remove several types of fiber posts using two different bur kits. Estimates refer to the time needed to pass the fiber post until arriving at the gutta-percha. Sixty extracted anterior teeth were treated endodontically. A post space with a standard depth of 10 mm was prepared in each root canal. The sample was randomly divided into 3 groups of 20 specimens each. Three different types of posts were cemented: group 1, Conic 6% tapered fiber posts (Ghimas); group 2, FRC Poster fiber posts (Ivoclar-Vivadent); and group 3, Composipost carbon fiber posts (RTD). To remove the post, for half of each group's specimens the burs from the RTD fiber posts removal kit were used (subgroup A). From the other half of the teeth in each group (subgroup B), posts were removed by using a diamond bur and a Largo bur. Composipost carbon fiber posts (group 3) took significantly less time to remove than the other two types of posts (p < 0.05). For the bur kits, the procedure involving the use of a diamond and a Largo bur (subgroup B) was significantly faster (p < 0.05). The interaction between the type of post and the type of bur kit used was not significant (p > 0.05).

  17. A novel kit for rapid detection of Vibrio cholerae O1.

    PubMed

    Hasan, J A; Huq, A; Tamplin, M L; Siebeling, R J; Colwell, R R

    1994-01-01

    We report on the development and testing of a novel, rapid, colorimetric immunodiagnostic kit, Cholera SMART, for direct detection of the presence of Vibrio cholerae O1 in clinical specimens. Unlike conventional culture methods requiring several days to complete, the Cholera SMART kit can be used directly in the field by untrained or minimally skilled personnel to detect V. cholerae O1 in less than 15 min, without cumbersome laboratory equipment. A total of 120 clinical and environmental bacterial strains, including both O1 and non-O1 serotypes of V. cholerae isolated from samples collected from a variety of geographical regions, were tested, and positive reactions were observed only with V. cholerae O1. Also, results of a field trial in Bangladesh, employing Cholera SMART, showed 100% specificity and 96% sensitivity compared with conventional culture methods. Another field trial, in Mexico, showed that Cholera SMART was 100% in agreement with a recently described coagglutination test when 108 stool specimens were tested.

  18. Oncogenic signaling by Kit tyrosine kinase occurs selectively on the Golgi apparatus in gastrointestinal stromal tumors

    PubMed Central

    Obata, Y; Horikawa, K; Takahashi, T; Akieda, Y; Tsujimoto, M; Fletcher, J A; Esumi, H; Nishida, T; Abe, R

    2017-01-01

    Gastrointestinal stromal tumors (GISTs) are caused by gain-of-function mutations in the Kit receptor tyrosine kinase. Most primary GIST patients respond to the Kit inhibitor imatinib, but this drug often becomes ineffective because of secondary mutations in the Kit kinase domain. The characteristic intracellular accumulation of imatinib-sensitive and -resistant Kit protein is well documented, but its relationship to oncogenic signaling remains unknown. Here, we show that in cancer tissue from primary GIST patients as well as in cell lines, mutant Kit accumulates on the Golgi apparatus, whereas normal Kit localizes to the plasma membrane (PM). In imatinib-resistant GIST with a secondary Kit mutation, Kit localizes predominantly on the Golgi apparatus. Both imatinib-sensitive and imatinib-resistant Kit (Kit(mut)) become fully auto-phosphorylated only on the Golgi and only if in a complex-glycosylated form. Kit(mut) accumulates on the Golgi during the early secretory pathway, but not after endocytosis. The aberrant kinase activity of Kit(mut) prevents its export from the Golgi to the PM. Furthermore, Kit(mut) on the Golgi signals and activates the phosphatidylinositol 3-kinase–Akt (PI3K–Akt) pathway, signal transducer and activator of transcription 5 (STAT5), and the Mek–Erk pathway. Blocking the biosynthetic transport of Kit(mut) to the Golgi from the endoplasmic reticulum inhibits oncogenic signaling. PM localization of Kit(mut) is not required for its signaling. Activation of Src-family tyrosine kinases on the Golgi is essential for oncogenic Kit signaling. These results suggest that the Golgi apparatus serves as a platform for oncogenic Kit signaling. Our study demonstrates that Kit(mut)’s pathogenicity is related to its mis-localization, and may offer a new strategy for treating imatinib-resistant GISTs. PMID:28192400

  19. Protein kinase C-δ-mediated recycling of active KIT in colon cancer.

    PubMed

    Park, Misun; Kim, Won Kyu; Song, Meiying; Park, Minhee; Kim, Hyunki; Nam, Hye Jin; Baek, Sung Hee; Kim, Hoguen

    2013-09-15

    Abnormal signaling through receptor tyrosine kinase (RTK) moieties is important in tumorigenesis and drug targeting of colorectal cancers. Wild-type KIT (WT-KIT), a RTK that is activated upon binding with stem cell factor (SCF), is highly expressed in some colon cancers; however, little is known about the functional role of SCF-dependent KIT activation in colon cancer pathogenesis. We aimed to elucidate the conditions and roles of WT-KIT activation in colon cancer tumorigenesis. Colorectal cancers with KIT expression were characterized by immunoblotting and immunohistochemistry. The biologic alterations after KIT-SCF binding were analyzed with or without protein kinase C (PKC) activation. We found that WT-KIT was expressed in a subset of colon cancer cell lines and was activated by SCF, leading to activation of downstream AKT and extracellular signal-regulated kinase (ERK) signaling pathways. We also showed that KIT expression gradually decreased, after prolonged SCF stimulation, due to lysosomal degradation. Degradation of WT-KIT after SCF binding was significantly rescued when PKC was activated. We also showed the involvement of activated PKC-δ in the recycling of WT-KIT. We further showed that a subset of colorectal cancers exhibit expressions of both WT-KIT and activated PKC-δ and that expression of KIT is correlated with poor patient survival (P = 0.004). Continuous downstream signal activation after KIT-SCF binding is accomplished through PKC-δ-mediated recycling of KIT. This sustained KIT activation may contribute to tumor progression in a subset of colon cancers with KIT expression and might provide the rationale for a therapeutic approach targeting KIT. ©2013 AACR.

  20. A single digital droplet PCR assay to detect multiple KIT exon 11 mutations in tumor and plasma from patients with gastrointestinal stromal tumors.

    PubMed

    Boonstra, Pieter A; Ter Elst, Arja; Tibbesma, Marco; Bosman, Lisette J; Mathijssen, Ron; Atrafi, Florence; van Coevorden, Frits; Steeghs, Neeltje; Farag, Sheima; Gelderblom, Hans; van der Graaf, Winette T A; Desar, Ingrid M E; Maier, Jacqueline; Overbosch, Jelle; Suurmeijer, Albert J H; Gietema, Jourik; Schuuring, Ed; Reyners, Anna K L

    2018-03-02

    Gastrointestinal stromal tumors (GISTs) are characterized by oncogenic KIT mutations that cluster in two exon 11 hotspots. The aim of this study was to develop a single, sensitive, quantitative digital droplet PCR (ddPCR) assay for the detection of common exon 11 mutations in both GIST tumor tissue and in circulating tumor DNA (ctDNA) isolated from GIST patients' plasma. A ddPCR assay was designed using two probes that cover both hotspots. Available archival FFPE tumor tissue from 27 consecutive patients with known KIT exon 11 mutations and 9 randomly selected patients without exon 11 mutations were tested. Plasma samples were prospectively collected in a multicenter bio-databank from December 2014. ctDNA was analyzed of 22 patients with an exon 11 mutation and a baseline plasma sample. The ddPCR assay detected the exon 11 mutation in 21 of 22 tumors with exon 11 mutations covered by the assay. Mutations in ctDNA were detected at baseline in 13 of 14 metastasized patients, but in only 1 of 8 patients with localized disease. In serial plasma samples from 11 patients with metastasized GIST, a decrease in mutant droplets was detected during treatment. According to RECIST 1.1, 10 patients had radiological treatment response and one patient stable disease. A single ddPCR assay for the detection of multiple exon 11 mutations in ctDNA is a feasible, promising tool for monitoring treatment response in patients with metastasized GIST and should be further evaluated in a larger cohort.

  1. Quantification of Fel d 1 in house dust samples of cat allergic patients by using monoclonal antibody specific to a novel IgE-binding epitope.

    PubMed

    Tasaniyananda, Natt; Tungtrongchitr, Anchalee; Seesuay, Watee; Sakolvaree, Yuwaporn; Aiumurai, Pisinee; Indrawattana, Nitaya; Chaicumpa, Wanpen; Sookrung, Nitat

    2018-03-01

    Avoidance of allergen exposure is an effective measure for preventing naÏve and allergic individuals from sensitization (primary intervention) and disease aggravation (secondary intervention), respectively. Regular monitoring of the allergens in the environment is required for the effective intervention. Thus, there is a need for cost-effective test kits for environmental allergen quantifications. To invent a test kit for quantification of cat major allergen, Fel d 1. A mouse monoclonal antibody (MAb) specific to the newly identified IgE-binding conformational epitope of the cat major allergen (Fel d 1) and rabbit polyclonal IgG to recombinant Fel d 1 were used as allergen capture and detection reagents, respectively. Native Fel d 1 was used in constructing a standard curve. Sixteen of 36 dust samples collected from houses of cat allergic subjects in Bangkok contained Fel d 1 above 0.29 μg/gram of dust which is considered as a novel threshold level for causing cat allergy sensitization or symptoms. Among them, 7 samples contained the allergen exceeding 2.35 μg/gram of dust which is the level that would aggravate asthma. Results of the allergen quantification using the locally made test kit showed strong correlation (r = 0.923) with the allergen quantification using commercialized reagents. The assay using MAb to Fel d 1 IgE-binding epitope of this study has potential application as an economic and practical tool for cat allergy intervention measure especially in localities where health resources are relatively limited.

  2. Immunoassay screening in urine for synthetic cannabinoids - an evaluation of the diagnostic efficiency.

    PubMed

    Franz, Florian; Angerer, Verena; Jechle, Hanna; Pegoro, Melanie; Ertl, Harald; Weinfurtner, Georg; Janele, David; Schlögl, Christian; Friedl, Matthias; Gerl, Stefan; Mielke, Reinhard; Zehnle, Ralf; Wagner, Matthias; Moosmann, Bjoern; Auwärter, Volker

    2017-08-28

    The abuse of synthetic cannabinoids (SCs) as presumed legal alternative to cannabis poses a great risk to public health. For economic reasons many laboratories use immunoassays (IAs) to screen for these substances in urine. However, the structural diversity and high potency of these designer drugs places high demands on IAs regarding cross-reactivity of the antibodies used and detection limits. Two retrospective studies were carried out in order to evaluate the capability of two homogenous enzyme IAs for the detection of currently prevalent SCs in authentic urine samples. Urine samples were analyzed utilizing a 'JWH-018' kit and a 'UR-144' kit. The IA results were confirmed by an up-to-date liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) screening method covering metabolites of 45 SCs. The first study (n=549) showed an 8% prevalence of SCs use (LC-MS/MS analysis) among inpatients of forensic-psychiatric clinics, whereas all samples were tested negative by the IAs. In a second study (n=200) the combined application of both IAs led to a sensitivity of 2% and a diagnostic accuracy of 51% when applying the recommended IA cut-offs. Overall, 10 different currently prevalent SCs were detected in this population. The results can be explained by an insufficient cross-reactivity of the antibodies towards current SCs in combination with relatively high detection limits of the IAs. In light of the presented study data it is strongly recommended not to rely on the evaluated IA tests for SCs in clinical or forensic settings. For IA kits of other providers similar results can be expected.

  3. Comparison of microscopy, ELISA, and real-time PCR for detection of Giardia intestinalis in human stool specimens

    PubMed

    Beyhan, Yunus Emre; Taş Cengiz, Zeynep

    2017-08-23

    Background/aim: This study included patients who had digestive system complaints between August 2015 and October 2015. The research was designed to compare conventional microscopy with an antigen detection ELISA kit and the TaqMan-based real-time PCR (RT-PCR) technique for detection of Giardia intestinalis in human stool specimens. Materials and methods: Samples were concentrated by formalin-ether sedimentation technique and microscopic examinations were carried out on wet mount slides. A commercially available ELISA kit (Giardia CELISA, Cellabs, Brookvale, Australia) was used for immunoassay. DNA was extracted from fecal samples of about 200 mg using the QIAamp Fast DNA Stool Mini Kit (QIAGEN, Hilden, Germany) and the LightCycler Nano system (Roche Diagnostics, Mannheim, Germany) was used for the TaqMan-based RT-PCR assay. Results: A total of 94 stool samples, 38 of them diagnosed positive (40.4%) and 56 of them diagnosed negative by microscopy, were selected for evaluation by antigen detection and molecular assays. The prevalence of G. intestinalis infection was found as 46.8% (n: 44) and 79.8% (n: 75) by ELISA and RT-PCR, respectively. RT-PCR revealed by far the highest positivity rate compared to the other two methods. The difference between these methods was found to be statistically significant (P < 0.05). In comparison to PCR, the sensitivity and specificity of microscopy and ELISA were 50.7% and 100% and 53.3% and 79%, respectively. Conclusion: RT-PCR seems to be much more sensitive and beneficial for rapid and accurate diagnosis of G. intestinalis in human stools.

  4. Rationale and design of the HOME trial: A pragmatic randomized controlled trial of home-based human papillomavirus (HPV) self-sampling for increasing cervical cancer screening uptake and effectiveness in a U.S. healthcare system.

    PubMed

    Winer, Rachel L; Tiro, Jasmin A; Miglioretti, Diana L; Thayer, Chris; Beatty, Tara; Lin, John; Gao, Hongyuan; Kimbel, Kilian; Buist, Diana S M

    2018-01-01

    Women who delay or do not attend Papanicolaou (Pap) screening are at increased risk for cervical cancer. Trials in countries with organized screening programs have demonstrated that mailing high-risk (hr) human papillomavirus (HPV) self-sampling kits to under-screened women increases participation, but U.S. data are lacking. HOME is a pragmatic randomized controlled trial set within a U.S. integrated healthcare delivery system to compare two programmatic approaches for increasing cervical cancer screening uptake and effectiveness in under-screened women (≥3.4years since last Pap) aged 30-64years: 1) usual care (annual patient reminders and ad hoc outreach by clinics) and 2) usual care plus mailed hrHPV self-screening kits. Over 2.5years, eligible women were identified through electronic medical record (EMR) data and randomized 1:1 to the intervention or control arm. Women in the intervention arm were mailed kits with pre-paid envelopes to return samples to the central clinical laboratory for hrHPV testing. Results were documented in the EMR to notify women's primary care providers of appropriate follow-up. Primary outcomes are detection and treatment of cervical neoplasia. Secondary outcomes are cervical cancer screening uptake, abnormal screening results, and women's experiences and attitudes towards hrHPV self-sampling and follow-up of hrHPV-positive results (measured through surveys and interviews). The trial was designed to evaluate whether a programmatic strategy incorporating hrHPV self-sampling is effective in promoting adherence to the complete screening process (including follow-up of abnormal screening results and treatment). The objective of this report is to describe the rationale and design of this pragmatic trial. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Improved Y-STR typing for disaster victim identification, missing persons investigations, and historical human skeletal remains.

    PubMed

    Ambers, Angie; Votrubova, Jitka; Vanek, Daniel; Sajantila, Antti; Budowle, Bruce

    2018-02-23

    Bones are a valuable source of DNA in forensic, anthropological, and archaeological investigations. There are a number of scenarios in which the only samples available for testing are highly degraded and/or skeletonized. Often it is necessary to perform more than one type of marker analysis on such samples in order to compile sufficient data for identification. Lineage markers, such as Y-STRs and mitochondrial DNA (mtDNA), represent important systems to complement autosomal DNA markers and anthropological metadata in making associations between unidentified remains and living relatives or for characterization of the remains for historical and archaeological studies. In this comparative study, Y-STR typing with both Yfiler™ and Yfiler™ Plus (Thermo Fisher Scientific, Waltham, MA, USA) was performed on a variety of human skeletal remains, including samples from the American Civil War (1861-1865), the late nineteenth century gold rush era in Deadwood, SD, USA (1874-1877), the Seven Years' War (1756-1763), a seventeenth-century archaeological site in Raspenava, Bohemia (Czech Republic), and World War II (1939-1945). The skeletal remains used for this study were recovered from a wide range of environmental conditions and were extracted using several common methods. Regardless of the DNA extraction method used and the age/condition of the remains, 22 out of 24 bone samples yielded a greater number of alleles using the Yfiler™ Plus kit compared to the Yfiler™ kit using the same quantity of input DNA. There was no discernable correlation with the degradation index values for these samples. Overall, the efficacy of the Yfiler™ Plus assay was demonstrated on degraded DNA from skeletal remains. Yfiler™ Plus increases the discriminatory power over the previous generation multiplex due to the larger set of Y-STR markers available for analysis and buffer modifications with the newer version kit. Increased haplotype resolution is provided to infer or refute putative genetic relationships.

  6. The effects of different polishing techniques on the staining resistance of CAD/CAM resin-ceramics

    PubMed Central

    Demirci, Tevfik; Demirci, Gamze; Sagsoz, Nurdan Polat; Yildiz, Mehmet

    2016-01-01

    PURPOSE The purposes of this study were to evaluate the staining resistance of CAD/CAM resin-ceramics polished with different techniques and to determine the effectiveness of the polishing techniques on resin-ceramics, comparing it with that of a glazed glass-ceramic. MATERIALS AND METHODS Four different CAD/CAM ceramics (feldspathic ceramic: C-CEREC Blocs, (SIRONA) and three resin-ceramics: L-Lava Ultimate, (3M ESPE), E-Enamic, (VITA) and CS-CeraSmart, (GC)) and one light cure composite resin: ME-Clearfil Majesty Esthetic (Kuraray) were used. Only C samples were glazed (gl). Other restorations were divided into four groups according to the polishing technique: nonpolished control group (c), a group polished with light cure liquid polish (Biscover LV BISCO) (bb), a group polished with ceramic polishing kit (Diapol, EVE) (cd), and a group polished with composite polishing kit (Clearfil Twist Dia, Kuraray) (kc). Glazed C samples and the polished samples were further divided into four subgroups and immersed into different solutions: distilled water, tea, coffee, and fermented black carrot juice. Eight samples (8 × 8 × 1 mm) were prepared for each subgroup. According to CIELab system, four color measurements were made: before immersion, immersion after 1 day, after 1 week, and after 1 month. Data were analyzed with repeated measures of ANOVA (α=.05). RESULTS The highest staining resistance was found in gl samples. There was no difference among gl, kc and cd (P>.05). Staining resistance of gl was significantly higher than that of bb (P<.05). Staining resistances of E and CS were significantly higher than those of L and ME (P<.05). CONCLUSION Ceramic and composite polishing kits can be used for resin ceramics as a counterpart of glazing procedure used for full ceramic materials. Liquid polish has limited indications for resin ceramics. PMID:28018558

  7. c-KIT receptor expression is strictly associated with the biological behaviour of thyroid nodules

    PubMed Central

    2012-01-01

    Background A large amount of information has been collected on the molecular tumorigenesis of thyroid cancer. A low expression of c-KIT gene has been reported during the transformation of normal thyroid epithelium to papillary carcinoma suggesting a possible role of the gene in the differentiation of thyroid tissue rather than in the proliferation. The initial presentation of thyroid carcinoma is through a nodule and the best way nowadays to evaluate it is by fine-needle aspiration (FNA). However many thyroid FNAs are not definitively benign or malignant, yielding an indeterminate or suspicious diagnosis which ranges from 10 to 25% of FNAs. BRAF mutational analysis is commonly used to assess the malignancy of thyroid nodules but unfortunately it still leaves indeterminate diagnoses. The development of molecular initial diagnostic tests for evaluating a thyroid nodule is needed in order to define optimal surgical approach for patients with uncertain diagnosis pre- and intra-operatively. Methods In this study we extracted RNA from 82 FNA smears, 46 malignant and 36 benign at the histology, in order to evaluate by quantitative Real Time PCR the expression levels of c-KIT gene. Results We have found a highly preferential decrease rather than increase in transcript of c-KIT in malignant thyroid lesions compared to the benign ones. To explore the diagnostic utility of c-KIT expression in thyroid nodules, its expression values were divided in four arbitrarily defined classes, with class I characterized by the complete silencing of the gene. Class I and IV represented the two most informative groups, with 100% of the samples found malignant or benign respectively. The molecular analysis was proven by ROC (receiver operating characteristic) analysis to be highly specific and sensitive improving the cytological diagnostic accuracy of 15%. Conclusion We propose the use of BRAF test (after uncertain cytological diagnosis) to assess the malignancy of thyroid nodules at first, then the use of the c-KIT expression to ultimately assess the diagnosis of the nodules that otherwise would remain suspicious. The c-KIT expression-based classification is highly accurate and may provide a tool to overcome the difficulties in today's preoperative diagnosis of thyroid suspicious malignancies. PMID:22233760

  8. Cardiac c-Kit Biology Revealed by Inducible Transgenesis.

    PubMed

    Gude, Natalie A; Firouzi, Fareheh; Broughton, Kathleen M; Ilves, Kelli; Nguyen, Kristine P; Payne, Christina R; Sacchi, Veronica; Monsanto, Megan M; Casillas, Alexandria R; Khalafalla, Farid G; Wang, Bingyan J; Ebeid, David E; Alvarez, Roberto; Dembitsky, Walter P; Bailey, Barbara A; van Berlo, Jop; Sussman, Mark A

    2018-06-22

    Biological significance of c-Kit as a cardiac stem cell marker and role(s) of c-Kit+ cells in myocardial development or response to pathological injury remain unresolved because of varied and discrepant findings. Alternative experimental models are required to contextualize and reconcile discordant published observations of cardiac c-Kit myocardial biology and provide meaningful insights regarding clinical relevance of c-Kit signaling for translational cell therapy. The main objectives of this study are as follows: demonstrating c-Kit myocardial biology through combined studies of both human and murine cardiac cells; advancing understanding of c-Kit myocardial biology through creation and characterization of a novel, inducible transgenic c-Kit reporter mouse model that overcomes limitations inherent to knock-in reporter models; and providing perspective to reconcile disparate viewpoints on c-Kit biology in the myocardium. In vitro studies confirm a critical role for c-Kit signaling in both cardiomyocytes and cardiac stem cells. Activation of c-Kit receptor promotes cell survival and proliferation in stem cells and cardiomyocytes of either human or murine origin. For creation of the mouse model, the cloned mouse c-Kit promoter drives Histone2B-EGFP (enhanced green fluorescent protein; H2BEGFP) expression in a doxycycline-inducible transgenic reporter line. The combination of c-Kit transgenesis coupled to H2BEGFP readout provides sensitive, specific, inducible, and persistent tracking of c-Kit promoter activation. Tagging efficiency for EGFP+/c-Kit+ cells is similar between our transgenic versus a c-Kit knock-in mouse line, but frequency of c-Kit+ cells in cardiac tissue from the knock-in model is 55% lower than that from our transgenic line. The c-Kit transgenic reporter model reveals intimate association of c-Kit expression with adult myocardial biology. Both cardiac stem cells and a subpopulation of cardiomyocytes express c-Kit in uninjured adult heart, upregulating c-Kit expression in response to pathological stress. c-Kit myocardial biology is more complex and varied than previously appreciated or documented, demonstrating validity in multiple points of coexisting yet heretofore seemingly irreconcilable published findings. © 2018 American Heart Association, Inc.

  9. Administration of imatinib mesylate in rats impairs the neonatal development of intramuscular interstitial cells in bladder and results in altered contractile properties.

    PubMed

    Gevaert, Thomas; Hutchings, Graham; Everaerts, Wouter; Prenen, Hans; Roskams, Tania; Nilius, Bernd; De Ridder, Dirk

    2014-04-01

    The KIT receptor is considered as a reliable marker for a subpopulation of interstitial cells (IC), and by persistent neonatal inhibition of KIT we have investigated the role of this receptor in the development of IC-networks in bladder and we have observed the functional consequences of this inhibition. Newborn rat pups were treated daily with the KIT inhibitor imatinib mesylate (IM). After 7 days animals were sacrificed and bladder samples were dissected for morphological and functional studies. Morphological research consisted of immunohistochemistry with IC specific antigens (KIT and vimentin) and electron microscopy. The functional studies were based on isolated bladder strips in organ baths, in which spontaneous bladder contractility and the response to a non-subtype selective muscarinic agonist was evaluated. Suburothelial and intramuscular IC were found and characterized in neonatal rat bladder. IM-treatment induced a significant decrease in numbers of IC based on specific immunohistochemical markers, and electron microscopy revealed evidence of IC cell injury. These morphological alterations were observed on intramuscular IC only and not on IC in the suburothelium. Isolated muscle strips from IM-treated animals had a lower contractile frequency and an altered response to muscarinic agonists. The present study shows the presence of regional subpopulations of IC in neonatal rat bladder, provides evidence for a dependence on KIT of the development of intramuscular IC and supports the hypothesis that a poor development of networks of intramuscular IC might have repercussions on spontaneous and muscarinic-induced bladder contractility. © 2013 Wiley Periodicals, Inc.

  10. MALDI-TOF for the rapid detection of carbapenemase-producing Enterobacteriaceae: comparison of the commercialized MBT STAR®-Carba IVD Kit with two in-house MALDI-TOF techniques and the RAPIDEC® CARBA NP.

    PubMed

    Dortet, Laurent; Tandé, Didier; de Briel, Dominique; Bernabeu, Sandrine; Lasserre, Camille; Gregorowicz, Guillaume; Jousset, Agnès B; Naas, Thierry

    2018-06-11

    There is an urgent need for accurate and fast diagnostic tests to identify carbapenemase-producing bacteria. Here, we have evaluated three MALDI-TOF-based techniques to detect carbapenemase-producing Enterobacteriaceae (CPE) from cultured colonies. The performance of three MALDI-TOF-based techniques, including the commercialized MBT STAR®-Carba IVD Kit (Bruker Daltonics) and two in-house protocols performed on the Microflex LT Biotyper (Bruker Daltonics) and the VITEK® MS Plus (bioMérieux), were compared with those of the RAPIDEC® CARBA NP (bioMérieux). A collection of 175 isolates including 120 carbapenemase producers and 55 non-carbapenemase producers was tested. Samples were tested blind in the three participating centres. The repeatability of the MBT STAR®-Carba IVD Kit was also evaluated. The three MALDI-TOF techniques possess sensitivities ranging from 95% to 100% and specificities from 98.2% to 100% compared with 99.2% and 100%, respectively, for the RAPIDEC® CARBA NP. The MBT STAR®-Carba IVD Kit gave highly reproducible results and is the only technique able to provide a concomitant identification of the bacterial isolate. The three MALDI-TOF techniques possess a fast turnaround time (less than 1.5 h). Overall, MALDI-TOF is a reliable technique for the rapid detection of CPE from cultured colonies. MBT STAR®-Carba IVD Kit, the only commercially available assay, could easily be implemented in a clinical microbiology laboratory if it is already equipped with a Microflex LT Biotyper mass spectrometer.

  11. Isolation, identification, and culture of goat spermatogonial stem cells using c-kit and PGP9.5 markers.

    PubMed

    Heidari, Banafsheh; Rahmati-Ahmadabadi, Maryam; Akhondi, Mohammad Mehdi; Zarnani, Amir Hassan; Jeddi-Tehrani, Mahmood; Shirazi, Abolfazl; Naderi, Mohammad Mehdi; Behzadi, Bahareh

    2012-10-01

    Presently the techniques for making transgenic animals are cumbersome, required costly instruments and trained man-power. The ability of spermatogonial stem cells (SSCs) to integrate foreign genes has provided the opportunity for developing alternate methods for generation of transgenic animals. One of the big challenges in this field is development of the methods to identify and purify donor SSCs by antibody mediated cell sorting. The present study was aimed to identify goat subpopulations of SSCs using polyclonal antibodies against PGP9.5 and c-kit molecular markers as well as the growth characteristics of SSCs during short term culture. One month old goats' testicular samples were subjected for immunohistochemical and immunocytochemical evaluations. The enzymatically isolated SSCs were cultured in DMEM plus FCS supplemented with (treatment) or without (control) growth factors (GDNF, LIF, FGF, and EGF) for 2 weeks. At the end of culture the morphological characteristics of SSCs colonies and immunocytochemical staining were evaluated. The number and size of colonies in treatment groups were significantly (P < 0.01) higher than corresponding values in controls. The presence of PGP 9.5 and c-kit antigens was confirmed in immunocytochemical evaluation. In immunocytochemical evaluation, the proportion of c-kit and PGP9.5 positive cells were significantly (P < 0.001) higher in control and treatment groups, respectively. The presence of PGP9.5 and c-kit antigens was confirmed in goat SSCs. Moreover, culture medium supplementation with growth factors could effectively retain the undifferentiation status of SSCs, reflected as a higher population of PGP9.5 positive cells, after short term culture.

  12. Familial gastrointestinal stromal tumors, lentigines, and café-au-lait macules associated with germline c-kit mutation treated with imatinib.

    PubMed

    Gupta, Divya; Chandrashekar, Laxmisha; Larizza, Lidia; Colombo, Elisa A; Fontana, Laura; Gervasini, Cristina; Thappa, Devinder M; Rajappa, Medha; Rajendiran, Kalai Selvi; Sreenath, Gubbi Shamanna; Kate, Vikram

    2017-02-01

    Familial lentiginosis syndromes are characterized by a wide array of manifestations resulting from activation of molecular pathways which control growth, proliferation, and differentiation of a broad range of tissues. Familial gastrointestinal stromal tumors (GISTs) are often accompanied by additional features like hyperpigmentation, mastocytosis, and dysphagia. They have been described with mutations in c-kit (most commonly), platelet-derived growth factor receptor A, neurofibromatosis-1, and succinate dehydrogenase genes. We report on molecular characterization and tumor histopathology of two siblings in whom lentigines and café-au-lait macules were present along with multifocal GIST. Immuhistochemical analysis of CD34 and CD117 was performed on GIST biopsy samples from both siblings, while c-kit mutational analysis was done by PCR and direct sequencing on DNA from peripheral blood leukocytes of all family members and from paraffin-embedded gastric biopsy specimens of affected siblings. Histopathology revealed positive expression of CD117 and CD34. Mutational analysis showed the germline c.1676T>C mutation in c-kit exon 11, (p.(Val559Ala)), in the peripheral blood of both siblings and a second exon 11 mutation, c.1669T>A (p.(Trp557Arg)) in the tumor biopsy of one of them. Initiation of imatinib treatment resulted in striking resolution of their hyperpigmentation and a stable gastrointestinal disease in one of them. A c-kit mutational test in familial GISTs is indicated before initiation of imatinib therapy, as it can help predict tumor response to treatment. © 2017 The International Society of Dermatology.

  13. "Finding the Right FIT": Rural Patient Preferences for Fecal Immunochemical Test (FIT) Characteristics.

    PubMed

    Pham, Robyn; Cross, Suzanne; Fernandez, Bianca; Corson, Kathryn; Dillon, Kristen; Yackley, Coco; Davis, Melinda M

    2017-01-01

    Colorectal cancer (CRC) is the third leading cause of cancer death in the United States, yet 1 in 3 Americans have never been screened for CRC. Annual screening using fecal immunochemical tests (FITs) is often a preferred modality in populations experiencing CRC screening disparities. Although multiple studies evaluate the clinical effectiveness of FITs, few studies assess patient preferences toward kit characteristics. We conducted this community-led study to assess patient preferences for FIT characteristics and to use study findings in concert with clinical effectiveness data to inform regional FIT selection. We collaborated with local health system leaders to identify FITs and recruit age eligible (50 to 75 years), English or Spanish speaking community members. Participants completed up to 6 FITs and associated questionnaires and were invited to participate in a follow-up focus group. We used a sequential explanatory mixed-methods design to assess participant preferences and rank FIT kits. First, we used quantitative data from user testing to measure acceptability, ease of completion, and specimen adequacy through a descriptive analysis of 1) fixed response questionnaire items on participant attitudes toward and experiences with FIT kits, and 2) a clinical assessment of adherence to directions regarding collection, packaging, and return of specimens. Second, we analyzed qualitative data from focus groups to refine FIT rankings and gain deeper insight into the pros and cons associated with each tested kit. Seventy-six FITs were completed by 18 participants (Range, 3 to 6 kits per participant). Over half (56%, n = 10) of the participants were Hispanic and 50% were female (n = 9). Thirteen participants attended 1 of 3 focus groups. Participants preferred FITs that were single sample, used a probe and vial for sample collection, and had simple, large-font instructions with colorful pictures. Participants reported challenges using paper to catch samples, had difficulty labeling tests, and emphasized the importance of having care team members provide verbal instructions on test completion and follow-up support for patients with abnormal results. FIT rankings from most to least preferred were OC-Light, Hemosure iFOB Test, InSure FIT, QuickVue, OneStep+, and Hemoccult ICT. FIT characteristics influenced patient's perceptions of test acceptability and feasibility. Health system leaders, payers, and clinicians should select FITs that are both clinically effective and incorporate patient preferred test characteristics. Consideration of patient preferences may facilitate FIT return, especially in populations at higher risk for experiencing CRC screening disparities. © Copyright 2017 by the American Board of Family Medicine.

  14. Wakata prepares for Surface Sample Kit (SSK) Collection/Incubation

    NASA Image and Video Library

    2009-04-29

    ISS019-E-012393 (29 April 2009) --- Japan Aerospace Exploration Agency (JAXA) astronaut Koichi Wakata, Expedition 19/20 flight engineer, is pictured near a Microbial Air Sampler floating freely in the Kibo laboratory of the International Space Station.

  15. Emerging role of HPV self-sampling in cervical cancer screening for hard-to-reach women: Focused literature review.

    PubMed

    Madzima, Tina R; Vahabi, Mandana; Lofters, Aisha

    2017-08-01

    To provide a focused critical review of the literature on the acceptability, feasibility, and uptake of human papillomavirus (HPV) self-sampling among hard-to-reach women. A focused search to obtain relevant literature published in English between 1997 and 2015 was done using PubMed and EMBASE using search terms including HPV self-test or HPV self-sample or HPV kit in combination with acceptability or feasibility . Only studies that focused on never-screened or underscreened populations were included in this review. Human papillomavirus self-sampling was found to be highly acceptable and feasible among these hard-to-reach women across most studies. Mailing of self-sampling kits has been shown to increase participation among hard-to reach women. Some concerns remain regarding adherence to further follow-up among high-risk women with positive test results for HPV after screening. There is a strong body of evidence to support the usefulness of HPV self-sampling in increasing participation of hard-to-reach women in screening programs (level I evidence). Convenience, privacy, ease of use, and, likely, cost-effectiveness of HPV self-sampling are driving forces in its emerging role in cervical cancer screening among hard-to-reach women. Key barriers to participation could be addressed by overcoming disparities in HPV-related knowledge and perceptions about cervical cancer screening. Copyright© the College of Family Physicians of Canada.

  16. Evaluation of the kinase domain of c-KIT in canine cutaneous mast cell tumors

    PubMed Central

    Webster, Joshua D; Kiupel, Matti; Yuzbasiyan-Gurkan, Vilma

    2006-01-01

    Background Mutations in the c-KIT proto-oncogene have been implicated in the progression of several neoplastic diseases, including gastrointestinal stromal tumors and mastocytosis in humans, and cutaneous mast cell tumors (MCTs) in canines. Mutations in human mastocytosis patients primarily occur in c-KIT exon 17, which encodes a portion of its kinase domain. In contrast, deletions and internal tandem duplication (ITD) mutations are found in the juxtamembrane domain of c-KIT in approximately 15% of canine MCTs. In addition, ITD c-KIT mutations are significantly associated with aberrant KIT protein localization in canine MCTs. However, some canine MCTs have aberrant KIT localization but lack ITD c-KIT mutations, suggesting that other mutations or other factors may be responsible for aberrant KIT localization in these tumors. Methods In order to characterize the prevalence of mutations in the phospho-transferase portion of c-KIT's kinase domain in canine MCTs exons 16–20 of 33 canine MCTs from 33 dogs were amplified and sequenced. Additionally, in order to determine if mutations in c-KIT exon 17 are responsible for aberrant KIT localization in MCTs that lack juxtamembrane domain c-KIT mutations, c-KIT exon 17 was amplified and sequenced from 18 canine MCTs that showed an aberrant KIT localization pattern but did not have ITD c-KIT mutations. Results No mutations or polymorphisms were identified in exons 16–20 of any of the MCTs examined. Conclusion In conclusion, mutations in the phospho-transferase portion of c-KIT's kinase domain do not play an important role in the progression of canine cutaneous MCTs, or in the aberrant localization of KIT in canine MCTs. PMID:16579858

  17. Fort Dix Remedial Investigation/Feasibility Study for MAG-1 Area

    DTIC Science & Technology

    1994-01-01

    by PID headspace results or odor ), samples should be diluted to bring the target compound concentrations within the instrument calibration range...Conductivity Testing ................... 2-38 2.9 ANALYTICAL PROCEDURES FOR FIELD SCREENING SAMPLES .. 2-38 2.9.1 Volatile Organic Compounds ...ANALYSIS OF VOLATILE ORGANIC COMPOUNDS BY FIELD GAS CHROMATOGRAPHY - STANDARD OPERATING PROCEDURE APPENDIX B RDX EXPLOSIVES FIELD TEST KIT PROCEDURES

  18. Adult cardiac stem cells are multipotent and robustly myogenic: c-kit expression is necessary but not sufficient for their identification.

    PubMed

    Vicinanza, Carla; Aquila, Iolanda; Scalise, Mariangela; Cristiano, Francesca; Marino, Fabiola; Cianflone, Eleonora; Mancuso, Teresa; Marotta, Pina; Sacco, Walter; Lewis, Fiona C; Couch, Liam; Shone, Victoria; Gritti, Giulia; Torella, Annalaura; Smith, Andrew J; Terracciano, Cesare Mn; Britti, Domenico; Veltri, Pierangelo; Indolfi, Ciro; Nadal-Ginard, Bernardo; Ellison-Hughes, Georgina M; Torella, Daniele

    2017-12-01

    Multipotent adult resident cardiac stem cells (CSCs) were first identified by the expression of c-kit, the stem cell factor receptor. However, in the adult myocardium c-kit alone cannot distinguish CSCs from other c-kit-expressing (c-kit pos ) cells. The adult heart indeed contains a heterogeneous mixture of c-kit pos cells, mainly composed of mast and endothelial/progenitor cells. This heterogeneity of cardiac c-kit pos cells has generated confusion and controversy about the existence and role of CSCs in the adult heart. Here, to unravel CSC identity within the heterogeneous c-kit-expressing cardiac cell population, c-kit pos cardiac cells were separated through CD45-positive or -negative sorting followed by c-kit pos sorting. The blood/endothelial lineage-committed (Lineage pos ) CD45 pos c-kit pos cardiac cells were compared to CD45 neg (Lineage neg /Lin neg ) c-kit pos cardiac cells for stemness and myogenic properties in vitro and in vivo. The majority (~90%) of the resident c-kit pos cardiac cells are blood/endothelial lineage-committed CD45 pos CD31 pos c-kit pos cells. In contrast, the Lin neg CD45 neg c-kit pos cardiac cell cohort, which represents ⩽10% of the total c-kit pos cells, contain all the cardiac cells with the properties of adult multipotent CSCs. These characteristics are absent from the c-kit neg and the blood/endothelial lineage-committed c-kit pos cardiac cells. Single Lin neg c-kit pos cell-derived clones, which represent only 1-2% of total c-kit pos myocardial cells, when stimulated with TGF-β/Wnt molecules, acquire full transcriptome and protein expression, sarcomere organisation, spontaneous contraction and electrophysiological properties of differentiated cardiomyocytes (CMs). Genetically tagged cloned progeny of one Lin neg c-kit pos cell when injected into the infarcted myocardium, results in significant regeneration of new CMs, arterioles and capillaries, derived from the injected cells. The CSC's myogenic regenerative capacity is dependent on commitment to the CM lineage through activation of the SMAD2 pathway. Such regeneration was not apparent when blood/endothelial lineage-committed c-kit pos cardiac cells were injected. Thus, among the cardiac c-kit pos cell cohort only a very small fraction has the phenotype and the differentiation/regenerative potential characteristics of true multipotent CSCs.

  19. Multiplex detection of agricultural pathogens

    DOEpatents

    Siezak, Thomas R.; Gardner, Shea; Torres, Clinton; Vitalis, Elizabeth; Lenhoff, Raymond J.

    2013-01-15

    Described are kits and methods useful for detection of agricultural pathogens in a sample. Genomic sequence information from agricultural pathogens was analyzed to identify signature sequences, e.g., polynucleotide sequences useful for confirming the presence or absence of a pathogen in a sample. Primer and probe sets were designed and optimized for use in a PCR based, multiplexed Luminex assay and/or an array assay to successfully identify the presence or absence of pathogens in a sample.

  20. Serotype and mating type characterization of Cryptococcus neoformans by multiplex PCR.

    PubMed

    Carvalho, Vívian Gonçalves; Terceti, Mateus Souza; Dias, Amanda Latercia Tranches; Paula, Claudete Rodrigues; Lyon, Juliana Pereira; de Siqueira, Antônio Martins; Franco, Marília Caixeta

    2007-01-01

    Cryptococcus neoformans is an encapsulated yeast, etiological agent of cryptococcosis. The species is commonly associated with pigeon droppings and plant materials. The aim of the present work was to verify the presence of the yeast in pigeon droppings, and to identify the isolates obtained in serotypes and mating types (MAT). Ten samples of pigeon droppings were collected in the rural area of the city of Alfenas, Brazil. Samples were inoculated in agar Niger medium for fungal isolation and 22 isolates with characteristics of C. neoformans were obtained. The serotypes and MAT were determined by multiplex PCR using specific primers. Serotypes were also determined by using the Kit Crypto Check. Among the 22 samples evaluated, eight were identified as C. neoformans by classic identification tests. These samples were characterized as serotype A by the Kit Crypto check and as serotype A MAT alpha by the multiplex PCR. The present study reinforces the evidence that pigeon droppings are a reservoir for C. neoformans and confirms the prevalence of C. neoformans var. grubii (A alpha) among environmental isolates. It also demonstrates that multiplex PCR is an acceptable alternative for serotype analysis because it reduces the costs for each reaction and analyses serotype and MAT simultaneously.

  1. Pathologic Stimulus Determines Lineage Commitment of Cardiac C-kit+ Cells.

    PubMed

    Chen, Zhongming; Zhu, Wuqiang; Bender, Ingrid; Gong, Wuming; Kwak, Il-Youp; Yellamilli, Amritha; Hodges, Thomas J; Nemoto, Natsumi; Zhang, Jianyi; Garry, Daniel J; van Berlo, Jop H

    2017-12-12

    Although cardiac c-kit + cells are being tested in clinical trials, the circumstances that determine lineage differentiation of c-kit + cells in vivo are unknown. Recent findings suggest that endogenous cardiac c-kit + cells rarely contribute cardiomyocytes to the adult heart. We assessed whether various pathological stimuli differentially affect the eventual cell fates of c-kit + cells. We used single-cell sequencing and genetic lineage tracing of c-kit + cells to determine whether various pathological stimuli would result in different fates of c-kit + cells. Single-cell sequencing of cardiac CD45 - c-kit + cells showed innate heterogeneity, indicative of the existence of vascular and mesenchymal c-kit + cells in normal hearts. Cardiac pressure overload resulted in a modest increase in c-kit-derived cardiomyocytes, with significant increases in the numbers of endothelial cells and fibroblasts. Doxorubicin-induced acute cardiotoxicity did not increase c-kit-derived endothelial cell fates but instead induced cardiomyocyte differentiation. Mechanistically, doxorubicin-induced DNA damage in c-kit + cells resulted in expression of p53. Inhibition of p53 blocked cardiomyocyte differentiation in response to doxorubicin, whereas stabilization of p53 was sufficient to increase c-kit-derived cardiomyocyte differentiation. These results demonstrate that different pathological stimuli induce different cell fates of c-kit + cells in vivo. Although the overall rate of cardiomyocyte formation from c-kit + cells is still below clinically relevant levels, we show that p53 is central to the ability of c-kit + cells to adopt cardiomyocyte fates, which could lead to the development of strategies to preferentially generate cardiomyocytes from c-kit + cells. © 2017 American Heart Association, Inc.

  2. The burden of the variability introduced by the HEp-2 assay kit and the CAD system in ANA indirect immunofluorescence test.

    PubMed

    Infantino, M; Meacci, F; Grossi, V; Manfredi, M; Benucci, M; Merone, M; Soda, P

    2017-02-01

    According to the recent recommendations of the American College of Rheumatology, ANA Task Force, IIF technique should be considered the gold standard in antinuclear antibodies (ANAs) testing. To overcome the lack of standardization, biomedical industries have developed several computer-aided diagnosis (CAD) systems. Two hundred and sixty-one consecutive samples with suspected autoimmune diseases were tested for ANA by means of IIF on routinely HEp-2 assay kit (Euroimmun AG). Assignment of result was made if consensus for positive/negative was reached by at least 2 out of 3 expert physicians. ANA-IIF was also carried out using 3 CAD systems: Zenit G-Sight (n = 84), Helios (n = 85) and NOVA View (n = 92); human evaluation was repeated on the same substrate of each CAD system (Immco, Aesku and Inova HEp-2 cells, respectively). To anonymize the results, we randomly named these three systems as A, B and C. We ran a statistical analysis computing several measures of agreement between the ratings, and we also improved the evaluation by using the Wilcoxon's test for nonparametric data. Agreement between the human readings on routinely HEp-2 assay kit and human readings on CAD HEp-2 assay was substantial for A (k = 0.82) and B (k = 0.72), and almost perfect for C (k = 0.89). Such readings were statistically different only in case A. Comparing experts' readings with the readings of CAD systems, when the samples were prepared using CAD HEp-2 assay kits, we found almost perfect agreement for B and C (k = 0.86; k = 0.82) and substantial agreement for A (k = 0.73). Again, human and CAD readings were statistically different only in A. When we compared the readings of medical experts on routinely HEp-2 assay kit with the output of the CAD systems that worked using their own slides, we found substantial agreement for all the systems (A: k = 0.62; B: k = 0.65; C: k = 0.71). Such readings were not statistically different. The change of the assay kit and/or the introduction of a CAD system affect the laboratory reporting, with an evident impact on the autoimmune laboratory workflow. The CAD systems may represent one of the most important novel elements of harmonization in the autoimmunity field, reducing intra- and inter-laboratory variability in a new vision of the diagnostic autoimmune platform.

  3. Multicenter evaluation of the Sepsityper™ extraction kit and MALDI-TOF MS for direct identification of positive blood culture isolates using the BD BACTEC™ FX and VersaTREK(®) diagnostic blood culture systems.

    PubMed

    Schieffer, K M; Tan, K E; Stamper, P D; Somogyi, A; Andrea, S B; Wakefield, T; Romagnoli, M; Chapin, K C; Wolk, D M; Carroll, K C

    2014-04-01

    (i) Evaluation of delayed time to blood culture extraction by the Sepsityper kit and impact of shipping pellets off-site for MALDI-TOF MS analysis. (ii) Comparison of Sepsityper and laboratory-developed extraction methods from a literature review. Using two blood culture systems (BD BACTEC and VersaTREK), we extracted 411 positive blood cultures using the Sepsityper kit to mimic a potential protocol for institutions without a MALDI-TOF MS. Extracted pellets were shipped and analysed on the Bruker UltraflexIII. Successful extraction of 358 (87·1%) samples was determined by the presence of detectable proteins. MALDI-TOF MS correctly identified 332 (80·8%) samples. Delayed time to extraction did not affect Sepsityper extraction or MALDI-TOF MS accuracy. The extracted pellets remain stable and provide accurate results by MALDI-TOF MS when shipped at room temperature to off-site reference laboratories. This is the first study to show that institutions without a MALDI-TOF MS can take advantage of this innovative technology by shipping a volume of blood to an off-site laboratory for extraction and MALDI-TOF MS analysis. We also performed a literature review to compare various extraction methods. © 2014 The Society for Applied Microbiology.

  4. Improved quantification of a commercial enzyme-linked immunosorbent assay kit for measuring anti-MDA5 antibody.

    PubMed

    Gono, Takahisa; Okazaki, Yuka; Murakami, Akihiro; Kuwana, Masataka

    2018-04-09

    To compare the quantitative performance for measuring anti-MDA5 antibody titer of two enzyme-linked immunosorbent assay (ELISA) systems: an in-house ELISA and the commercial MESACUP TM anti-MDA5 test. Anti-MDA5 antibody titer was measured in sera from 70 patients with dermatomyositis using an in-house ELISA and the MESACUP TM anti-MDA5 test side-by-side. For the commercial ELISA kit, serum samples diluted 1:101 were used according to the manufacturer's protocol, but serial dilutions of sera were also examined to identify the optimal serum dilution for quantification. The anti-MDA5 antibody titers measured by the in-house and commercial ELISAs were positively correlated with each other (r = 0.53, p = .0001), but the antibody titer measured by the commercial ELISA was less sensitive to change after medical treatment, and 37 (80%) of 46 anti-MDA5-positive sera had antibody titer exceeding the quantification range specified by the manufacturer (≥150 index). Experiments using diluted serum samples revealed that diluting the sera 1:5050 improved the quantitative performance of the MESACUP TM anti-MDA5 test, including a better correlation with the in-house ELISA results and an increased sensitivity to change. We improved the ability of the commercial ELISA kit to quantify anti-MDA5 antibody titer by altering its protocol.

  5. Comparison of six commercial tick-borne encephalitis IgM and IgG ELISA kits and the molecular characterization of their antigenic design.

    PubMed

    Velay, Aurélie; Solis, Morgane; Barth, Heidi; Sohn, Véronique; Moncollin, Anne; Neeb, Amandine; Wendling, Marie-Josée; Fafi-Kremer, Samira

    2018-04-01

    Tick-borne encephalitis virus (TBEV) diagnosis is mainly based on the detection of viral-specific antibodies in serum. Several commercial assays are available, but published data on their performance remain unclear. We assessed six IgM and six IgG commercial enzyme-linked immunosorbent assay (ELISA) kits (ELISA-1 through ELISA-6) using 94 samples, including precharacterized TBEV-positive samples (n=50) and -negative samples (n=44). The six manufacturers showed satisfactory sensitivity and specificity and high overall agreement for both IgM and IgG. Three manufacturers showed better reproducibility and were the most sensitive (100%) and specific (95.5-98.1%) for both IgM and IgG. Two of them were also in agreement with the clinical interpretation in more than 90% of the cases. All the assays use inactivated virus as antigen, with strains showing approximately 94% homology at the amino acid level. The antigenic format of the assays was discussed to further improve this TBEV diagnostic tool. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Receptor tyrosine kinase (c-Kit) inhibitors: a potential therapeutic target in cancer cells

    PubMed Central

    Abbaspour Babaei, Maryam; Kamalidehghan, Behnam; Saleem, Mohammad; Huri, Hasniza Zaman; Ahmadipour, Fatemeh

    2016-01-01

    c-Kit, a receptor tyrosine kinase, is involved in intracellular signaling, and the mutated form of c-Kit plays a crucial role in occurrence of some cancers. The function of c-Kit has led to the concept that inhibiting c-Kit kinase activity can be a target for cancer therapy. The promising results of inhibition of c-Kit for treatment of cancers have been observed in some cancers such as gastrointestinal stromal tumor, acute myeloid leukemia, melanoma, and other tumors, and these results have encouraged attempts toward improvement of using c-Kit as a capable target for cancer therapy. This paper presents the findings of previous studies regarding c-Kit as a receptor tyrosine kinase and an oncogene, as well as its gene targets and signaling pathways in normal and cancer cells. The c-Kit gene location, protein structure, and the role of c-Kit in normal cell have been discussed. Comprehending the molecular mechanism underlying c-Kit-mediated tumorogenesis is consequently essential and may lead to the identification of future novel drug targets. The potential mechanisms by which c-Kit induces cellular transformation have been described. This study aims to elucidate the function of c-Kit for future cancer therapy. In addition, it has c-Kit inhibitor drug properties and their functions have been listed in tables and demonstrated in schematic pictures. This review also has collected previous studies that targeted c-Kit as a novel strategy for cancer therapy. This paper further emphasizes the advantages of this approach, as well as the limitations that must be addressed in the future. Finally, although c-Kit is an attractive target for cancer therapy, based on the outcomes of treatment of patients with c-Kit inhibitors, it is unlikely that Kit inhibitors alone can lead to cure. It seems that c-Kit mutations alone are not sufficient for tumorogenesis, but do play a crucial role in cancer occurrence. PMID:27536065

  7. Stability of Dosage Forms in the Pharmaceutical Payload Aboard Space Missions

    NASA Technical Reports Server (NTRS)

    Du, Brian J.; Daniels, Vernie; Boyd, Jason L.; Crady, Camille; Satterfield, Rick; Younker, Diane R.; Putcha, Lakshmi

    2009-01-01

    Efficacious pharmaceuticals with adequate shelf lives are essential for successful space medical operations. Stability of pharmaceuticals, therefore, is of paramount importance for assuring the health and wellness of astronauts on future space exploration missions. Unique physical and environmental factors of space missions may contribute to the instability of pharmaceuticals, e.g., radiation, humidity and temperature variations. Degradation of pharmaceutical formulations can result in inadequate efficacy and/or untoward toxic effects, which could compromise astronaut safety and health. Methods: Four identical pharmaceutical payload kits containing 31 medications in different dosage forms (liquid, tablet, capsule, ointment and suppository) were transported to the International Space Station aboard the Space Shuttle (STS-121). One of the 4 kits was stored on the Shuttle and the other 3 were stored on the International Space Station (ISS) for return to Earth at 6-month interval aboard a pre-designated Shuttle flight for each kit. The kit stored on the Shuttle was returned to Earth aboard STS-121 and 2 kits from ISS were returned on STS 117 and STS-122. Results: Analysis of standard physical and chemical parameters of degradation was completed for pharmaceuticals returned by STS-121 after14 days, STS - 117 after11 months and STS 122 after 19 months storage aboard ISS. Analysis of all flight samples along with ground-based matching controls was completed and results were compiled. Conclusion: Evaluation of results from the shuttle (1) and ISS increments (2) indicate that the number of formulations degraded in space increased with duration of storage in space and was higher in space compared to their ground-based counterparts. Rate of degradation for some of the formulations tested was faster in space than on Earth. Additionally, some of the formulations included in the medical kits were unstable, more so in space than on the ground. These results indicate that the space flight environment may adversely affect the shelf life of pharmaceuticals aboard space missions.

  8. Evaluation of lot-to-lot repeatability and effect of assay media choice in the recombinant Factor C assay.

    PubMed

    McKenzie, Jennifer Helen; Alwis, K Udeni; Sordillo, Joanne E; Kalluri, Kesava Srinivas; Milton, Donald Kirby

    2011-06-01

    Measurement of environmental endotoxin exposures is complicated by variability encountered using current biological assay methods arising in part from lot-to-lot variability of the Limulus-amebocyte lysate (LAL) reagents. Therefore, we investigated the lot-to-lot repeatability of commercially available recombinant Factor C (rFC) kits as an alternative to LAL. Specifically, we compared endotoxin estimates obtained from rFC assay of twenty indoor dust samples, using four different extraction and assay media, to endotoxin estimates previously obtained by Limulus amebocyte lysate (LAL) assay and amounts of 3-hydroxy fatty acids (3-OHFA) in lipopolysaccharide (LPS) using gas-chromatography mass spectroscopy (GC-MS). We found that lot-to-lot variability of the rFC assay kits does not significantly alter endotoxin estimates in house dust samples when performed using three of the four assay media tested and that choice of assay media significantly altered endotoxin estimates obtained by rFC assay of house dust samples. Our findings demonstrate lot-to-lot reproducibility of rFC assay of environmental samples and suggest that use of rFC assay performed with Tris buffer or water as the extraction and assay medium for measurement of endotoxin in dust samples may be a suitable choice for developing a standardized methodology.

  9. SHP-1 Binds and Negatively Modulates the c-Kit Receptor by Interaction with Tyrosine 569 in the c-Kit Juxtamembrane Domain

    PubMed Central

    Kozlowski, Maya; Larose, Louise; Lee, Fai; Le, Duc Mingh; Rottapel, Robert; Siminovitch, Katherine A.

    1998-01-01

    The SH2 domain-containing SHP-1 tyrosine phosphatase has been shown to negatively regulate a broad spectrum of growth factor- and cytokine-driven mitogenic signaling pathways. Included among these is the cascade of intracellular events evoked by stem cell factor binding to c-Kit, a tyrosine kinase receptor which associates with and is dephosphorylated by SHP-1. Using a series of glutathione S-transferase (GST) fusion proteins containing either tyrosine-phosphorylated segments of the c-Kit cytosolic region or the SH2 domains of SHP-1, we have shown that SHP-1 interacts with c-Kit by binding selectively to the phosphorylated c-Kit juxtamembrane region and that the association of c-Kit with the larger of the two SHP-1 isoforms may be mediated through either the N-terminal or C-terminal SHP-1 SH2 domain. The results of binding assays with mutagenized GST-Kit juxtamembrane fusion proteins and competitive inhibition assays with phosphopeptides encompassing each c-Kit juxtamembrane region identified the tyrosine residue at position 569 as the major site for binding of SHP-1 to c-Kit and suggested that tyrosine 567 contributes to, but is not required for, this interaction. By analysis of Ba/F3 cells retrovirally transduced to express c-Kit receptors, phenylalanine substitution of c-Kit tyrosine residue 569 was shown to be associated with disruption of c-Kit–SHP-1 binding and induction of hyperproliferative responses to stem cell factor. Although phenylalanine substitution of c-Kit tyrosine residue 567 in the Ba/F3–c-Kit cells did not alter SHP-1 binding to c-Kit, the capacity of a second c-Kit-binding tyrosine phosphatase, SHP-2, to associate with c-Kit was markedly reduced, and the cells again showed hyperproliferative responses to stem cell factor. These data therefore identify SHP-1 binding to tyrosine 569 on c-Kit as an interaction pivotal to SHP-1 inhibitory effects on c-Kit signaling, but they indicate as well that cytosolic protein tyrosine phosphatases other than SHP-1 may also negatively regulate the coupling of c-Kit engagement to proliferation. PMID:9528781

  10. Identification of mutations in the coding sequence of the proto-oncogene c-kit in a human mast cell leukemia cell line causing ligand-independent activation of c-kit product.

    PubMed Central

    Furitsu, T; Tsujimura, T; Tono, T; Ikeda, H; Kitayama, H; Koshimizu, U; Sugahara, H; Butterfield, J H; Ashman, L K; Kanayama, Y

    1993-01-01

    The c-kit proto-oncogene encodes a receptor tyrosine kinase. Binding of c-kit ligand, stem cell factor (SCF) to c-kit receptor (c-kitR) is known to activate c-kitR tyrosine kinase, thereby leading to autophosphorylation of c-kitR on tyrosine and to association of c-kitR with substrates such as phosphatidylinositol 3-kinase (PI3K). In a human mast cell leukemia cell line HMC-1, c-kitR was found to be constitutively phosphorylated on tyrosine, activated, and associated with PI3K without the addition of SCF. The expression of SCF mRNA transcript in HMC-1 cells was not detectable by means of PCR after reverse transcription (RT-PCR) analysis, suggesting that the constitutive activation of c-kitR was ligand independent. Sequencing of whole coding region of c-kit cDNA revealed that c-kit genes of HMC-1 cells were composed of a normal, wild-type allele and a mutant allele with two point mutations resulting in intracellular amino acid substitutions of Gly-560 for Val and Val-816 for Asp. Amino acid sequences in the regions of the two mutations are completely conserved in all of mouse, rat, and human c-kit. In order to determine the causal role of these mutations in the constitutive activation, murine c-kit mutants encoding Gly-559 and/or Val-814, corresponding to human Gly-560 and/or Val-816, were constructed by site-directed mutagenesis and expressed in a human embryonic kidney cell line, 293T cells. In the transfected cells, both c-kitR (Gly-559, Val-814) and c-kitR (Val-814) were abundantly phosphorylated on tyrosine and activated in immune complex kinase reaction in the absence of SCF, whereas tyrosine phosphorylation and activation of c-kitR (Gly-559) or wild-type c-kitR was modest or little, respectively. These results suggest that conversion of Asp-816 to Val in human c-kitR may be an activating mutation and responsible for the constitutive activation of c-kitR in HMC-1 cells. Images PMID:7691885

  11. Distinct cellular properties of oncogenic KIT receptor tyrosine kinase mutants enable alternative courses of cancer cell inhibition

    PubMed Central

    Shi, Xiarong; Sousa, Leiliane P.; Mandel-Bausch, Elizabeth M.; Tome, Francisco; Reshetnyak, Andrey V.; Hadari, Yaron; Schlessinger, Joseph; Lax, Irit

    2016-01-01

    Large genomic sequencing analysis as part of precision medicine efforts revealed numerous activating mutations in receptor tyrosine kinases, including KIT. Unfortunately, a single approach is not effective for inhibiting cancer cells or treating cancers driven by all known oncogenic KIT mutants. Here, we show that each of the six major KIT oncogenic mutants exhibits different enzymatic, cellular, and dynamic properties and responds distinctly to different KIT inhibitors. One class of KIT mutants responded well to anti-KIT antibody treatment alone or in combination with a low dose of tyrosine kinase inhibitors (TKIs). A second class of KIT mutants, including a mutant resistant to imatinib treatment, responded well to a combination of TKI with anti-KIT antibodies or to anti-KIT toxin conjugates, respectively. We conclude that the preferred choice of precision medicine treatments for cancers driven by activated KIT and other RTKs may rely on clear understanding of the dynamic properties of oncogenic mutants. PMID:27482095

  12. Megakaryocytes compensate for Kit insufficiency in murine arthritis.

    PubMed

    Cunin, Pierre; Penke, Loka R; Thon, Jonathan N; Monach, Paul A; Jones, Tatiana; Chang, Margaret H; Chen, Mary M; Melki, Imene; Lacroix, Steve; Iwakura, Yoichiro; Ware, Jerry; Gurish, Michael F; Italiano, Joseph E; Boilard, Eric; Nigrovic, Peter A

    2017-05-01

    The growth factor receptor Kit is involved in hematopoietic and nonhematopoietic development. Mice bearing Kit defects lack mast cells; however, strains bearing different Kit alleles exhibit diverse phenotypes. Herein, we investigated factors underlying differential sensitivity to IgG-mediated arthritis in 2 mast cell-deficient murine lines: KitWsh/Wsh, which develops robust arthritis, and KitW/Wv, which does not. Reciprocal bone marrow transplantation between KitW/Wv and KitWsh/Wsh mice revealed that arthritis resistance reflects a hematopoietic defect in addition to mast cell deficiency. In KitW/Wv mice, restoration of susceptibility to IgG-mediated arthritis was neutrophil independent but required IL-1 and the platelet/megakaryocyte markers NF-E2 and glycoprotein VI. In KitW/Wv mice, platelets were present in numbers similar to those in WT animals and functionally intact, and transfer of WT platelets did not restore arthritis susceptibility. These data implicated a platelet-independent role for the megakaryocyte, a Kit-dependent lineage that is selectively deficient in KitW/Wv mice. Megakaryocytes secreted IL-1 directly and as a component of circulating microparticles, which activated synovial fibroblasts in an IL-1-dependent manner. Transfer of WT but not IL-1-deficient megakaryocytes restored arthritis susceptibility to KitW/Wv mice. These findings identify functional redundancy among Kit-dependent hematopoietic lineages and establish an unanticipated capacity of megakaryocytes to mediate IL-1-driven systemic inflammatory disease.

  13. How to Combine ChIP with qPCR.

    PubMed

    Asp, Patrik

    2018-01-01

    Chromatin immunoprecipitation (ChIP) coupled with quantitative PCR (qPCR) has in the last 15 years become a basic mainstream tool in genomic research. Numerous commercially available ChIP kits, qPCR kits, and real-time PCR systems allow for quick and easy analysis of virtually anything chromatin-related as long as there is an available antibody. However, the highly accurate quantitative dimension added by using qPCR to analyze ChIP samples significantly raises the bar in terms of experimental accuracy, appropriate controls, data analysis, and data presentation. This chapter will address these potential pitfalls by providing protocols and procedures that address the difficulties inherent in ChIP-qPCR assays.

  14. Multiplex detection of agricultural pathogens

    DOEpatents

    McBride, Mary Teresa; Slezak, Thomas Richard; Messenger, Sharon Lee

    2010-09-14

    Described are kits and methods useful for detection of seven agricultural pathogens (BPSV; BHV; BVD; FMDV; BTV; SVD; and VESV) in a sample. Genomic sequence information from 7 agricultural pathogens was analyzed to identify signature sequences, e.g., polynucleotide sequences useful for confirming the presence or absence of a pathogen in a sample. Primer and probe sets were designed and optimized for use in a PCR based, multiplexed Luminex assay to successfully identify the presence or absence of pathogens in a sample.

  15. Female Reproductive Effects of Exposure to Jet Fuel at U.S. Air Force Bases

    DTIC Science & Technology

    1998-11-01

    volunteers during 1997. Volunteers then provided feedback about the process and made suggestions for improvement. This information was used to develop...breath samples were processed in the field by collecting one (1) liter of expired breath in a Tedlar bag which was subsequently introduced onto a...also alert him when samples were obtained thru to menses. The process for returning samples was also facilitated by the provision of a mailing kit

  16. Signal transduction by normal isoforms and W mutant variants of the Kit receptor tyrosine kinase.

    PubMed

    Reith, A D; Ellis, C; Lyman, S D; Anderson, D M; Williams, D E; Bernstein, A; Pawson, T

    1991-09-01

    Germline mutations at the Dominant White Spotting (W) and Steel (Sl) loci have provided conclusive genetic evidence that c-kit mediated signal transduction pathways are essential for normal mouse development. We have analysed the interactions of normal and mutant W/c-kit gene products with cytoplasmic signalling proteins, using transient c-kit expression assays in COS cells. In addition to the previously identified c-kit gene product (Kit+), a second normal Kit isoform (KitA+) containing an in-frame insertion, Gly-Asn-Asn-Lys, within the extracellular domain, was detected in murine mast cell cultures and mid-gestation placenta. Both Kit+ and KitA+ isoforms showed increased autophosphorylation and enhanced association with phosphatidylinositol (PI) 3' kinase and PLC gamma 1, when stimulated with recombinant soluble Steel factor. No association or increase in phosphorylation of GAP and two GAP-associated proteins, p62 and p190, was observed. The two isoforms had distinct activities in the absence of exogenous soluble Steel factor; Kit+, but not KitA+, showed constitutive tyrosine phosphorylation that was accompanied by a low constitutive level of association with PI-3' kinase and PLC gamma 1. Introduction of the point substitutions associated with W37 (Glu582----Lys) or W41 (Val831----Met) mutant alleles into c-kit expression constructs abolished (W37) or reduced (W41) the Steel factor-induced association of the Kit receptor with signalling proteins in a manner proportional to the overall severity of the corresponding W mutant phenotype. These data suggest a diversity of normal Kit signalling pathways and indicate that W mutant phenotypes result from primary defects in the Kit receptor that affect its interaction with cytoplasmic signalling proteins.

  17. The development of miniplex primer sets for the analysis of degraded DNA

    NASA Astrophysics Data System (ADS)

    McCord, Bruce; Opel, Kerry; Chung, Denise; Drabek, Jiri; Tatarek, Nancy; Meadows Jantz, Lee; Butler, John

    2005-05-01

    In this project, a new set of multiplexed PCR reactions has been developed for the analysis of degraded DNA. These DNA markers, known as Miniplexes, utilize primers that have shorter amplicons for use in short tandem repeat (STR) analysis of degraded DNA. In our work we have defined six of these new STR multiplexes, each of which consists of 3 to 4 reduced size STR loci, and each labeled with a different fluorescent dye. When compared to commercially available STR systems, reductions in size of up to 300 basepairs are possible. In addition, these newly designed amplicons consist of loci that are fully compatible with the the national computer DNA database known as CODIS. To demonstrate compatibility with commercial STR kits, a concordance study of 532 DNA samples of Caucasian, African American, and Hispanic origin was undertaken There was 99.77% concordance between allele calls with the two methods. Of these 532 samples, only 15 samples showed discrepancies at one of 12 loci. These occurred predominantly at 2 loci, vWA and D13S317. DNA sequencing revealed that these locations had deletions between the two primer binding sites. Uncommon deletions like these can be expected in certain samples and will not affect the utility of the Miniplexes as tools for degraded DNA analysis. The Miniplexes were also applied to enzymatically digested DNA to assess their potential in degraded DNA analysis. The results demonstrated a greatly improved efficiency in the analysis of degraded DNA when compared to commercial STR genotyping kits. A series of human skeletal remains that had been exposed to a variety of environmental conditions were also examined. Sixty-four percent of the samples generated full profiles when amplified with the Miniplexes, while only sixteen percent of the samples tested generated full profiles with a commercial kit. In addition, complete profiles were obtained for eleven of the twelve Miniplex loci which had amplicon size ranges less than 200 base pairs. These data clearly demonstrate that smaller PCR amplicons provide an attractive alternative to mitochondrial DNA for forensic analysis of degraded DNA.

  18. Ratio Based Biomarkers for the Prediction of Cancer Survival | NCI Technology Transfer Center | TTC

    Cancer.gov

    The NCI seeks licensees or co-development partners for this technology, which describes compositions, methods and kits for identifying, characterizing biomolecules expressed in a sample that are associated with the presence, the development, or progression of cancer.

  19. Bowersox works with the WMK in Destiny during Expedition Six

    NASA Image and Video Library

    2003-02-17

    ISS006-E-27226 (17 February 2003) --- Astronaut Kenneth D. Bowersox, Expedition Six mission commander, uses the water microbiology kit (WMK) to collect water samples for in-flight chemistry/microbiology analysis in the Destiny laboratory on the International Space Station (ISS).

  20. FE-2 Stott analyzes Water Samples using the CQQMK in the US Lab

    NASA Image and Video Library

    2009-10-20

    ISS021-E-010311 (20 Oct. 2009) --- NASA astronaut Nicole Stott, Expedition 21 flight engineer, conducts a water quality analysis using the Colorimetric Water Quality Monitoring Kit (CWQMK) in the Destiny laboratory of the International Space Station.

  1. Identification of a common single nucleotide polymorphism at the primer binding site of D2S1360 that causes heterozygote peak imbalance when using the Investigator HDplex Kit.

    PubMed

    Inokuchi, Shota; Yamashita, Yasuhiro; Nishimura, Kazuma; Nakanishi, Hiroaki; Saito, Kazuyuki

    2017-11-01

    Phenomena known as null alleles and peak imbalance can occur because of mutations in the primer binding sites used for DNA typing. In these cases, an accurate statistical evaluation of DNA typing is difficult. The estimated likelihood ratio is incorrectly calculated because of the null allele and allele dropout caused by mutation-induced peak imbalance. Although a number of studies have attempted to uncover examples of these phenomena, few reports are available on the human identification kit manufactured by Qiagen. In this study, 196 Japanese individuals who were heterozygous at D2S1360 were genotyped using an Investigator HDplex Kit with optimal amounts of DNA. A peak imbalance was frequently observed at the D2S1360 locus. We performed a sequencing analysis of the area surrounding the D2S1360 repeat motif to identify the cause for peak imbalance. A point mutation (G>A transition) 136 nucleotides upstream from the D2S1360 repeat motif was discovered in a number of samples. The allele frequency of the mutation was 0.0566 in the Japanese population. Therefore, human identification or kinship testing using the Investigator HDplex Kit requires caution because of the higher frequency of single nucleotide polymorphisms at the primer binding site of D2S1360 locus in the Japanese population.

  2. MicroSEQ® Salmonella spp. Detection Kit Using the Pathatrix® 10-Pooling Salmonella spp. Kit Linked Protocol Method Modification.

    PubMed

    Wall, Jason; Conrad, Rick; Latham, Kathy; Liu, Eric

    2014-03-01

    Real-time PCR methods for detecting foodborne pathogens offer the advantages of simplicity and quick time to results compared to traditional culture methods. The addition of a recirculating pooled immunomagnetic separation method prior to real-time PCR analysis increases processing output while reducing both cost and labor. This AOAC Research Institute method modification study validates the MicroSEQ® Salmonella spp. Detection Kit [AOAC Performance Tested Method (PTM) 031001] linked with the Pathatrix® 10-Pooling Salmonella spp. Kit (AOAC PTM 090203C) in diced tomatoes, chocolate, and deli ham. The Pathatrix 10-Pooling protocol represents a method modification of the enrichment portion of the MicroSEQ Salmonella spp. The results of the method modification were compared to standard cultural reference methods for diced tomatoes, chocolate, and deli ham. All three matrixes were analyzed in a paired study design. An additional set of chocolate test portions was analyzed using an alternative enrichment medium in an unpaired study design. For all matrixes tested, there were no statistically significant differences in the number of positive test portions detected by the modified candidate method compared to the appropriate reference method. The MicroSEQ Salmonella spp. protocol linked with the Pathatrix individual or 10-Pooling procedure demonstrated reliability as a rapid, simplified, method for the preparation of samples and subsequent detection of Salmonella in diced tomatoes, chocolate, and deli ham.

  3. Field determination of PCB in transformer oil. Volume 2. Clor-N-Oil PCB screening test. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisher, D.J.; Rouse, T.O.; Lynn, T.

    1984-10-01

    The requirements for handling and disposing of transformer minerals oils containing more than 50 ppM PCB are, by federal regulation, different from those for oils containing lower concentrations. A rapid and simple test to distinguish between samples containing more than or less than this concentration would simplify proper control of transformer oils. This report describes the development of a small disposable test kit that can be used on-site to screen the chlorine content of transformer oils. The kit consists of two soft plastic tubes in which thin walled glass ampules containing premeasured amounts of reagents are broken. The reaction sequencemore » in the kits converts the chlorine in PCB to chloride ion. The color of the liquid in the kit after the last step is blue to purple if the chloride content due to the initial chlorine concentration of the oil is less than 20 ppM. If the chlorine content of the oil is below 20 ppM, the PCB content must be below 50 ppM. The liquid is colorless if the chlorine content is greater than 20 ppM. In this latter case, it is necessary to determine by gas chromatography whether the PCB content is actually greater than 50 ppM or if there is some other source of chlorine in the oil.« less

  4. Germline mutations of KIT in gastrointestinal stromal tumor (GIST) and mastocytosis.

    PubMed

    Ke, Hengning; Kazi, Julhash U; Zhao, Hui; Sun, Jianmin

    2016-01-01

    Somatic mutations of KIT are frequently found in mastocytosis and gastrointestinal stromal tumor (GIST), while germline mutations of KIT are rare, and only found in few cases of familial GIST and mastocytosis. Although ligand-independent activation is the common feature of KIT mutations, the phenotypes mediated by various germline KIT mutations are different. Germline KIT mutations affect different tissues such as interstitial cells of Cajal (ICC), mast cells or melanocytes, and thereby lead to GIST, mastocytosis, or abnormal pigmentation. In this review, we summarize germline KIT mutations in familial mastocytosis and GIST and discuss the possible cellular context dependent transforming activity of KIT mutations.

  5. The challenges of lean manufacturing implementation in kitting assembly

    NASA Astrophysics Data System (ADS)

    Fansuri, A. F. H.; Rose, A. N. M.; Nik Mohamed, N. M. Z.; Ahmad, H.

    2017-10-01

    Literature studies shows that lean manufacturing goes way back with the original founder Eli Whitney in year 1799. The main purpose of lean manufacturing is to identify and eliminate waste in production. The application of lean manufacturing can be carried out in any industrial processes with regards to the understanding of lean principles, theories and practices. Kitting is one of the important aspects in a successful production. The continuous supply of materials from store to production has to be systematic and able to achieve lean standard for it to be successful. The objective of this paper is to review the implementation of lean manufacturing in kitting assembly. Previous papers show that, the implementation of lean manufacturing in kitting assembly may be beneficial to the organization such as reduce in space occupancy, part shortages, lead time and manpower. Based on previous research, some industries may tend to change between kitting and line stocking which are due to lack of understanding when implementing kitting and causes longer lead time and materials overflow in store. With a proper understanding on what to kit, where to kit, how to kit, why to kit and who kits the material with a standardised process flow may ensure the success of kitting.

  6. No GIST-type c-kit gain of function mutations in neuroblastic tumours

    PubMed Central

    Korja, M; Finne, J; Salmi, T T; Haapasalo, H; Tanner, M; Isola, J

    2005-01-01

    Aims: Neuroblastic tumours (NTs) have been shown to respond to imatinib treatment in vivo and in vitro, possibly via inactivating the c-kit receptor. The purpose of this study was to identify gastrointestinal stromal tumour (GIST)-type c-kit gene associated mutations in exons 9, 11, 13, and 17 in NTs to recognise a subset of tumours that would probably respond to imatinib treatment. Methods: Expression of the c-kit protein was detected immunohistochemically in a total of 37 archival paraffin wax embedded NTs using polyclonal rabbit antihuman c-kit antibody. After immunohistochemistry, c-kit gene associated chromosomal mutations in all cases of NT were detected with denaturing high performance liquid chromatography (HPLC). Results: Denaturing HLPC analysis did not reveal GIST-type mutations in four immunohistochemically detected c-kit positive or in 33 c-kit negative NTs. Conclusions: c-kit receptor expression and GIST-type c-kit gene mutations are rare events in NTs. Oncogenic activation of c-kit in NTs presumably differs from that of GISTs, which may influence their responsiveness to imatinib treatment. Whether c-kit has an essential role in the pathogenesis of NTs remains to be investigated. PMID:15976348

  7. Portable kit for identification and detection of drugs in human urine using surface-enhanced Raman spectroscopy.

    PubMed

    Han, Zhenzhen; Liu, Honglin; Meng, Juan; Yang, Liangbao; Liu, Jing; Liu, Jinhuai

    2015-09-15

    A portable kit was demonstrated for rapid and reliable surface-enhanced Raman scattering (SERS) detection of drugs in human urine. This kit contains two sealed reagent tubes, a packet of standardized SERS substrates, and a mini Raman device. A 3 min pretreatment for separating amphetamines from human urine was developed with an extraction rate of >80% examined by ultraperformance liquid chromatography (UPLC). Simultaneously, highly reproducible two-dimensional (2D) gold nanorod (GNR) arrays were assembled by the use of methoxymercaptopoly(ethylene glycol) (mPEG-SH) capping. Thirty batches of GNR arrays produced the 1001 cm(-1) intensity of methamphetamine (MA) molecules with a relative standard deviation (RSD) of 7.9%, and a 21 × 21 μm(2) area mapping on a 2D GNR array produced a statistical RSD of <10%, implying an excellent reproducibility and uniformity. The detection limit of amphetamines in human urine was at least 0.1 ppm. Moreover, the portable kit was successfully used for detecting MA, 3,4-methylenedioxymethamphetamine (MDMA), and methcathinone (MC) in 30 volunteers' urine samples with various clinical natures, and the dual-analyte detection of MA and MDMA implied a good capability of multiplex analysis. UPLC examination and the SERS recovery test clearly indicated that our pretreatment procedure was sufficient to lower the high background signals caused by complex components in urine and demonstrated the practicability and the resistance to false positives, which is a vital problem for law enforcement applications. The excellent performance of our portable kit promises a great prospective toward a rapid, reliable, and on-spot analyzer, especially for public safety and healthcare.

  8. Paternity tests in Mexico: Results obtained in 3005 cases.

    PubMed

    García-Aceves, M E; Romero Rentería, O; Díaz-Navarro, X X; Rangel-Villalobos, H

    2018-04-01

    National and international reports regarding the paternity testing activity scarcely include information from Mexico and other Latin American countries. Therefore, we report different results from the analysis of 3005 paternity cases analyzed during a period of five years in a Mexican paternity testing laboratory. Motherless tests were the most frequent (77.27%), followed by trio cases (20.70%); the remaining 2.04% included different cases of kinship reconstruction. The paternity exclusion rate was 29.58%, higher but into the range reported by the American Association of Blood Banks (average 24.12%). We detected 65 mutations, most of them involving one-step (93.8% and the remaining were two-step mutations (6.2%) thus, we were able to estimate the paternal mutation rate for 17 different STR loci: 0.0018 (95% CI 0.0005-0.0047). Five triallelic patterns and 12 suspected null alleles were detected during this period; however, re-amplification of these samples with a different Human Identification (HID) kit confirmed the homozygous genotypes, which suggests that most of these exclusions actually are one-step mutations. HID kits with ≥20 STRs detected more exclusions, diminishing the rate of inconclusive results with isolated exclusions (<3 loci), and leading to higher paternity indexes (PI). However, the Powerplex 21 kit (20 STRs) and Powerplex Fusion kit (22 STRs) offered similar PI (p = 0.379) and average number of exclusions (PE) (p = 0.339) when a daughter was involved in motherless tests. In brief, besides to report forensic parameters from paternity tests in Mexico, results describe improvements to solve motherless paternity tests using HID kits with ≥20 STRs instead of one including 15 STRs. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  9. Characterization and functionality of cardiac progenitor cells in congenital heart patients.

    PubMed

    Mishra, Rachana; Vijayan, Kalpana; Colletti, Evan J; Harrington, Daniel A; Matthiesen, Thomas S; Simpson, David; Goh, Saik Kia; Walker, Brandon L; Almeida-Porada, Graça; Wang, Deli; Backer, Carl L; Dudley, Samuel C; Wold, Loren E; Kaushal, Sunjay

    2011-02-01

    Human cardiac progenitor cells (hCPCs) may promote myocardial regeneration in adult ischemic myocardium. The regenerative capacity of hCPCs in young patients with nonischemic congenital heart defects for potential use in congenital heart defect repair warrants exploration. Human right atrial specimens were obtained during routine congenital cardiac surgery across 3 groups: neonates (age, <30 days), infants (age, 1 month to 2 years), and children (age, >2 to ≤13 years). C-kit(+) hCPCs were 3-fold higher in neonates than in children >2 years of age. hCPC proliferation was greatest during the neonatal period as evidenced by c-kit(+) Ki67(+) expression but decreased with age. hCPC differentiation capacity was also greatest in neonatal right atrium as evidenced by c-kit(+), NKX2-5(+), NOTCH1(+), and NUMB(+) expression. Despite the age-dependent decline in resident hCPCs, we isolated and expanded right atrium-derived CPCs from all patients (n=103) across all ages and diagnoses using the cardiosphere method. Intact cardiospheres contained a mix of heart-derived cell subpopulations that included cardiac progenitor cells expressing c-kit(+), Islet-1, and supporting cells. The number of c-kit(+)-expressing cells was highest in human cardiosphere-derived cells (hCDCs) grown from neonatal and infant right atrium. Furthermore, hCDCs could differentiate into diverse cardiovascular lineages by in vitro differentiation assays. Transplanted hCDCs promoted greater myocardial regeneration and functional improvement in infarcted myocardium than transplanted cardiac fibroblasts. Resident hCPCs are most abundant in the neonatal period and rapidly decrease over time. hCDCs can be reproducibly isolated and expanded from young human myocardial samples regardless of age or diagnosis. hCPCs are functional and have potential in congenital cardiac repair.

  10. Development of a qualitative, multiplex real-time PCR kit for screening of genetically modified organisms (GMOs).

    PubMed

    Dörries, Hans-Henno; Remus, Ivonne; Grönewald, Astrid; Grönewald, Cordt; Berghof-Jäger, Kornelia

    2010-03-01

    The number of commercially available genetically modified organisms (GMOs) and therefore the diversity of possible target sequences for molecular detection techniques are constantly increasing. As a result, GMO laboratories and the food production industry currently are forced to apply many different methods to reliably test raw material and complex processed food products. Screening methods have become more and more relevant to minimize the analytical effort and to make a preselection for further analysis (e.g., specific identification or quantification of the GMO). A multiplex real-time PCR kit was developed to detect the 35S promoter of the cauliflower mosaic virus, the terminator of the nopaline synthase gene of Agrobacterium tumefaciens, the 35S promoter from the figwort mosaic virus, and the bar gene of the soil bacterium Streptomyces hygroscopicus as the most widely used sequences in GMOs. The kit contains a second assay for the detection of plant-derived DNA to control the quality of the often processed and refined sample material. Additionally, the plant-specific assay comprises a homologous internal amplification control for inhibition control. The determined limits of detection for the five assays were 10 target copies/reaction. No amplification products were observed with DNAs of 26 bacterial species, 25 yeasts, 13 molds, and 41 not genetically modified plants. The specificity of the assays was further demonstrated to be 100% by the specific amplification of DNA derived from reference material from 22 genetically modified crops. The applicability of the kit in routine laboratory use was verified by testing of 50 spiked and unspiked food products. The herein described kit represents a simple and sensitive GMO screening method for the reliable detection of multiple GMO-specific target sequences in a multiplex real-time PCR reaction.

  11. Female users of internet-based screening for rectal STIs: descriptive statistics and correlates of positivity.

    PubMed

    Ladd, Jessica; Hsieh, Yu-Hsiang; Barnes, Mathilda; Quinn, Nicole; Jett-Goheen, Mary; Gaydos, Charlotte A

    2014-09-01

    Internet-based screening for vaginal sexually transmitted infections (STI) has been shown to reach high-risk populations. Published studies of internet-based screening for rectal STIs in women are needed. Our objectives were to describe the female users of a rectal internet-based screening intervention and assess what factors correlated with rectal positivity for STIs. The website http://www.iwantthekit.org offers free STI testing via home self-sampling kits. Women could order vaginal and rectal kits, both containing questionnaires. Rectal and vaginal swabs were tested for Chlamydia trachomatis, Neisseria gonorrhoeae and Trichomonas vaginalis using nucleic acid amplification tests. Data were analysed from 205 rectal kits from January 2009 through February 2011. Self-reported characteristics of participants were examined, and correlates of rectal STI positivity were analysed. Of the 205 rectal samples returned and eligible for testing, 38 (18.5%) were positive for at least one STI. The women were young (mean age 25.8 years), mostly African-American (50.0%), and only 14.0% always used condoms. After adjusting for age and race, Black race (AOR=3.06) and vaginal STI positivity (AOR=40.6) were significantly correlated with rectal STI positivity. Of women testing positive for rectal STIs who also submitted vaginal swabs, 29.4% were negative in the vaginal sample. Internet-based rectal screening can reach populations that appear to be at high risk for rectal STIs (18.5% prevalence) and led to the diagnosis of STIs in women who would not have been diagnosed vaginally. Black race and vaginal STI positivity were highly correlated with rectal STI positivity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Whole-exome sequencing identifies recurrent SF3B1 R625 mutation and comutation of NF1 and KIT in mucosal melanoma.

    PubMed

    Hintzsche, Jennifer D; Gorden, Nicholas T; Amato, Carol M; Kim, Jihye; Wuensch, Kelsey E; Robinson, Steven E; Applegate, Allison J; Couts, Kasey L; Medina, Theresa M; Wells, Keith R; Wisell, Joshua A; McCarter, Martin D; Box, Neil F; Shellman, Yiqun G; Gonzalez, Rene C; Lewis, Karl D; Tentler, John J; Tan, Aik Choon; Robinson, William A

    2017-06-01

    Mucosal melanomas are a rare subtype of melanoma, arising in mucosal tissues, which have a very poor prognosis due to the lack of effective targeted therapies. This study aimed to better understand the molecular landscape of these cancers and find potential new therapeutic targets. Whole-exome sequencing was performed on mucosal melanomas from 19 patients and 135 sun-exposed cutaneous melanomas, with matched peripheral blood samples when available. Mutational profiles were compared between mucosal subgroups and sun-exposed cutaneous melanomas. Comparisons of molecular profiles identified 161 genes enriched in mucosal melanoma (P<0.05). KIT and NF1 were frequently comutated (32%) in the mucosal subgroup, with a significantly higher incidence than that in cutaneous melanoma (4%). Recurrent SF3B1 R625H/S/C mutations were identified and validated in 7 of 19 (37%) mucosal melanoma patients. Mutations in the spliceosome pathway were found to be enriched in mucosal melanomas when compared with cutaneous melanomas. Alternative splicing in four genes were observed in SF3B1-mutant samples compared with the wild-type samples. This study identified potential new therapeutic targets for mucosal melanoma, including comutation of NF1 and KIT, and recurrent R625 mutations in SF3B1. This is the first report of SF3B1 R625 mutations in vulvovaginal mucosal melanoma, with the largest whole-exome sequencing project of mucosal melanomas to date. The results here also indicated that the mutations in SF3B1 lead to alternative splicing in multiple genes. These findings expand our knowledge of this rare disease.

  13. Whole-exome sequencing identifies recurrent SF3B1 R625 mutation and comutation of NF1 and KIT in mucosal melanoma

    PubMed Central

    Hintzsche, Jennifer D.; Gorden, Nicholas T.; Amato, Carol M.; Kim, Jihye; Wuensch, Kelsey E.; Robinson, Steven E.; Applegate, Allison J.; Couts, Kasey L.; Medina, Theresa M.; Wells, Keith R.; Wisell, Joshua A.; McCarter, Martin D.; Box, Neil F.; Shellman, Yiqun G.; Gonzalez, Rene C.; Lewis, Karl D.; Tentler, John J.

    2017-01-01

    Mucosal melanomas are a rare subtype of melanoma, arising in mucosal tissues, which have a very poor prognosis due to the lack of effective targeted therapies. This study aimed to better understand the molecular landscape of these cancers and find potential new therapeutic targets. Whole-exome sequencing was performed on mucosal melanomas from 19 patients and 135 sun-exposed cutaneous melanomas, with matched peripheral blood samples when available. Mutational profiles were compared between mucosal subgroups and sun-exposed cutaneous melanomas. Comparisons of molecular profiles identified 161 genes enriched in mucosal melanoma (P<0.05). KIT and NF1 were frequently comutated (32%) in the mucosal subgroup, with a significantly higher incidence than that in cutaneous melanoma (4%). Recurrent SF3B1 R625H/S/C mutations were identified and validated in 7 of 19 (37%) mucosal melanoma patients. Mutations in the spliceosome pathway were found to be enriched in mucosal melanomas when compared with cutaneous melanomas. Alternative splicing in four genes were observed in SF3B1-mutant samples compared with the wild-type samples. This study identified potential new therapeutic targets for mucosal melanoma, including comutation of NF1 and KIT, and recurrent R625 mutations in SF3B1. This is the first report of SF3B1 R625 mutations in vulvovaginal mucosal melanoma, with the largest whole-exome sequencing project of mucosal melanomas to date. The results here also indicated that the mutations in SF3B1 lead to alternative splicing in multiple genes. These findings expand our knowledge of this rare disease. PMID:28296713

  14. Small RNA profiling of low biomass samples: identification and removal of contaminants.

    PubMed

    Heintz-Buschart, Anna; Yusuf, Dilmurat; Kaysen, Anne; Etheridge, Alton; Fritz, Joëlle V; May, Patrick; de Beaufort, Carine; Upadhyaya, Bimal B; Ghosal, Anubrata; Galas, David J; Wilmes, Paul

    2018-05-14

    Sequencing-based analyses of low-biomass samples are known to be prone to misinterpretation due to the potential presence of contaminating molecules derived from laboratory reagents and environments. DNA contamination has been previously reported, yet contamination with RNA is usually considered to be very unlikely due to its inherent instability. Small RNAs (sRNAs) identified in tissues and bodily fluids, such as blood plasma, have implications for physiology and pathology, and therefore the potential to act as disease biomarkers. Thus, the possibility for RNA contaminants demands careful evaluation. Herein, we report on the presence of small RNA (sRNA) contaminants in widely used microRNA extraction kits and propose an approach for their depletion. We sequenced sRNAs extracted from human plasma samples and detected important levels of non-human (exogenous) sequences whose source could be traced to the microRNA extraction columns through a careful qPCR-based analysis of several laboratory reagents. Furthermore, we also detected the presence of artefactual sequences related to these contaminants in a range of published datasets, thereby arguing in particular for a re-evaluation of reports suggesting the presence of exogenous RNAs of microbial and dietary origin in blood plasma. To avoid artefacts in future experiments, we also devise several protocols for the removal of contaminant RNAs, define minimal amounts of starting material for artefact-free analyses, and confirm the reduction of contaminant levels for identification of bona fide sequences using 'ultra-clean' extraction kits. This is the first report on the presence of RNA molecules as contaminants in RNA extraction kits. The described protocols should be applied in the future to avoid confounding sRNA studies.

  15. Pim1 kinase regulates c-Kit gene translation.

    PubMed

    An, Ningfei; Cen, Bo; Cai, Houjian; Song, Jin H; Kraft, Andrew; Kang, Yubin

    2016-01-01

    Receptor tyrosine kinase, c-Kit (CD117) plays a pivotal role in the maintenance and expansion of hematopoietic stem/progenitor cells (HSPCs). Additionally, over-expression and/or mutational activation of c-Kit have been implicated in numerous malignant diseases including acute myeloid leukemia. However, the translational regulation of c-Kit expression remains largely unknown. We demonstrated that loss of Pim1 led to specific down-regulation of c-Kit expression in HSPCs of Pim1 -/- mice and Pim1 -/- 2 -/- 3 -/- triple knockout (TKO) mice, and resulted in attenuated ERK and STAT3 signaling in response to stimulation with stem cell factor. Transduction of c-Kit restored the defects in colony forming capacity seen in HSPCs from Pim1 -/- and TKO mice. Pharmacologic inhibition and genetic modification studies using human megakaryoblastic leukemia cells confirmed the regulation of c-Kit expression by Pim1 kinase: i.e., Pim1-specific shRNA knockdown down-regulated the expression of c-Kit whereas overexpression of Pim1 up-regulated the expression of c-Kit. Mechanistically, inhibition or knockout of Pim1 kinase did not affect the transcription of c-Kit gene. Pim1 kinase enhanced c-Kit 35 S methionine labeling and increased the incorporation of c-Kit mRNAs into the polysomes and monosomes, demonstrating that Pim1 kinase regulates c-Kit expression at the translational level. Our study provides the first evidence that Pim1 regulates c-Kit gene translation and has important implications in hematopoietic stem cell transplantation and cancer treatment.

  16. Early kit mortality and growth in farmed mink are affected by litter size rather than nest climate.

    PubMed

    Schou, T M; Malmkvist, J

    2017-09-01

    We investigated the effects of nest box climate on early mink kit mortality and growth. We hypothesised that litters in warm nest boxes experience less hypothermia-induced mortality and higher growth rates during the 1st week of life. This study included data from 749, 1-year-old breeding dams with access to nesting materials. Kits were weighed on days 1 and 7, dead kits were collected daily from birth until day 7 after birth, and nest climate was measured continuously from days 1 to 6. We tested the influences of the following daily temperature (T) and humidity (H) parameters on the number of live-born kit deaths and kit growth: T mean, T min, T max, T var (fluctuation) and H mean. The nest microclimate experienced by the kits was buffered against the ambient climate, with higher temperatures and reduced climate fluctuation. Most (77.0%) live-born kit deaths in the 1st week occurred on days 0 and 1. Seven of 15 climate parameters on days 1 to 3 had significant effects on live-born kit mortality. However, conflicting effects among days, marginal effects and late effects indicated that climate was not the primary cause of kit mortality. Five of 30 climate parameters had significant effects on kit growth. Few and conflicting effects indicated that the climate effect on growth was negligible. One exception was that large nest temperature fluctuations on day 1 were associated with reduced deaths of live-born kit (P<0.001) and increased kit growth (P=0.003). Litter size affected kit vitality; larger total litter size at birth was associated with greater risks of kit death (P<0.001) and reduced growth (P<0.001). The number of living kits in litters had the opposite effect, as kits in large liveborn litters had a reduced risk of death (P<0.001) and those with large mean litter size on days 1 to 7 had increased growth (P=0.026). Nest box temperature had little effect on early kit survival and growth, which could be due to dams' additional maternal behaviour. Therefore, we cannot confirm that temperature is the primary reason for kit mortality, under the conditions of plenty straw access for maternal nest building. Instead, prenatal and/or parturient litter size is the primary factor influencing early kit vitality. The results indicate that the focus should be on litter size and dam welfare around the times of gestation and birth to increase early kit survival in farmed mink.

  17. The clinical significance of c-Kit mutations in metastatic oral mucosal melanoma in China.

    PubMed

    Ma, Xuhui; Wu, Yunteng; Zhang, Tian; Song, Hao; Jv, Houyu; Guo, Wei; Ren, Guoxin

    2017-10-10

    c-Kit mutations are frequently detected in mucosal melanomas, but their clinical significance in metastatic oral mucosal melanomas (OMM) remains unclear. The main purpose of this study was to investigate the clinical and pathological features of metastatic OMMs with c-Kit mutations and the efficiency of the tyrosine kinase inhibitor imatinib in treating metastatic OMMs. We found thatresidual primary lesion and neck lymph nodes could act as independent prognostic factors in metastatic OMM patients. c-Kit mutations were detected in 22 out of 139 (15.8%) metastatic OMM patients. Under chemotherapy, the overall survival (OS) of c-Kit mutant patients was significantly shorter than that of wild-type patients. The Ki67 expression was significantly higher in c-Kit mutant patients than in wild-type patients. In distant metastatic OMM patients with c-Kit mutations, the treatment with c-Kit inhibitor resulted in a better OS. In conclusion, residual primary lesion, cervical lymph nodes and c-Kit mutations act as adverse prognostic factors of metastatic OMMs. The Kit inhibitor imatinib could benefit metastatic OMM patients with c-Kit mutations.

  18. Serum samples can be substituted by plasma samples for the diagnosis of paratuberculosis.

    PubMed

    Goodridge, Amador; Correa, Ricardo; Castro, Paul; Escobar, Cecilia; de Waard, Jacobus H

    2013-10-01

    Employing plasma samples rather than serum samples for serological paratuberculosis diagnosis is practical, especially when bovine TB is assessed in the same cattle herd with the gamma interferon bovine avian (IFN-γ BA) test. We demonstrate that antibody titers in serum and plasma samples, utilizing the PARACHECK(®) ELISA kit, are highly comparable (Cohen's kappa test, k=0.955). We conclude that serum can be replaced with plasma in this commercially available antibody detection assay resulting in working hour savings for sampling and blood sample work-up and cost reductions for materials and sample storage. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Intratumoral CD3+ T-Lymphocytes Immunoexpression and Its Association with c-Kit, Angiogenesis, and Overall Survival in Malignant Canine Mammary Tumors

    PubMed Central

    Carvalho, Maria Isabel; Pires, Isabel; Dias, Marlene; Prada, Justina; Gregório, Hugo; Lobo, Luis; Queiroga, Felisbina

    2015-01-01

    In this study 80 malignant CMT were submitted to immunohistochemical detection of CD3, c-kit, VEGF, and CD31, together with clinicopathological parameters of tumor aggressiveness. CD3+ T-cells and c-kit overexpression revealed a positive correlation with VEGF (r = 0.503, P < 0.0001; r = 0.284, P = 0.023 for CD3 and c-kit, resp.) and CD31 (r = 0.654, P < 0.0001; r = 0.365, P = 0.003 for CD3 and c-kit, resp.). A significant association (P = 0.039) and a positive correlation (r = 0.263, P = 0.039) between CD3 and c-kit were also observed. High CD3/VEGF, c-kit/VEGF, and CD3/c-kit tumors were associated with elevated grade of malignancy (P < 0.0001 for all groups), presence of intravascular emboli (P < 0.0001 for CD3/VEGF and CD3/c-kit; P = 0.002 for c-kit/VEGF), and presence of lymph node metastasis (P < 0.0001 for all groups). Tumors with high CD3/VEGF (P = 0.006), c-kit/VEGF (P < 0.0001), and CD3/c-kit (P = 0.002) were associated with poor prognosis. Interestingly high c-kit/VEGF tumors retained their significance by multivariate analysis arising as independent prognostic factor. PMID:26346272

  20. Evaluation of commercially available small RNASeq library preparation kits using low input RNA.

    PubMed

    Yeri, Ashish; Courtright, Amanda; Danielson, Kirsty; Hutchins, Elizabeth; Alsop, Eric; Carlson, Elizabeth; Hsieh, Michael; Ziegler, Olivia; Das, Avash; Shah, Ravi V; Rozowsky, Joel; Das, Saumya; Van Keuren-Jensen, Kendall

    2018-05-05

    Evolving interest in comprehensively profiling the full range of small RNAs present in small tissue biopsies and in circulating biofluids, and how the profile differs with disease, has launched small RNA sequencing (RNASeq) into more frequent use. However, known biases associated with small RNASeq, compounded by low RNA inputs, have been both a significant concern and a hurdle to widespread adoption. As RNASeq is becoming a viable choice for the discovery of small RNAs in low input samples and more labs are employing it, there should be benchmark datasets to test and evaluate the performance of new sequencing protocols and operators. In a recent publication from the National Institute of Standards and Technology, Pine et al., 2018, the investigators used a commercially available set of three tissues and tested performance across labs and platforms. In this paper, we further tested the performance of low RNA input in three commonly used and commercially available RNASeq library preparation kits; NEB Next, NEXTFlex, and TruSeq small RNA library preparation. We evaluated the performance of the kits at two different sites, using three different tissues (brain, liver, and placenta) with high (1 μg) and low RNA (10 ng) input from tissue samples, or 5.0, 3.0, 2.0, 1.0, 0.5, and 0.2 ml starting volumes of plasma. As there has been a lack of robust validation platforms for differentially expressed miRNAs, we also compared low input RNASeq data with their expression profiles on three different platforms (Abcam Fireplex, HTG EdgeSeq, and Qiagen miRNome). The concordance of RNASeq results on these three platforms was dependent on the RNA expression level; the higher the expression, the better the reproducibility. The results provide an extensive analysis of small RNASeq kit performance using low RNA input, and replication of these data on three downstream technologies.

Top