Sample records for sampling protocols analytical

  1. Validating Analytical Protocols to Determine Selected Pesticides and PCBs Using Routine Samples.

    PubMed

    Pindado Jiménez, Oscar; García Alonso, Susana; Pérez Pastor, Rosa María

    2017-01-01

    This study aims at providing recommendations concerning the validation of analytical protocols by using routine samples. It is intended to provide a case-study on how to validate the analytical methods in different environmental matrices. In order to analyze the selected compounds (pesticides and polychlorinated biphenyls) in two different environmental matrices, the current work has performed and validated two analytical procedures by GC-MS. A description is given of the validation of the two protocols by the analysis of more than 30 samples of water and sediments collected along nine months. The present work also scopes the uncertainty associated with both analytical protocols. In detail, uncertainty of water sample was performed through a conventional approach. However, for the sediments matrices, the estimation of proportional/constant bias is also included due to its inhomogeneity. Results for the sediment matrix are reliable, showing a range 25-35% of analytical variability associated with intermediate conditions. The analytical methodology for the water matrix determines the selected compounds with acceptable recoveries and the combined uncertainty ranges between 20 and 30%. Analyzing routine samples is rarely applied to assess trueness of novel analytical methods and up to now this methodology was not focused on organochlorine compounds in environmental matrices.

  2. HSRP and HSRP Partner Analytical Methods and Protocols

    EPA Pesticide Factsheets

    HSRP has worked with various partners to develop and test analytical methods and protocols for use by laboratories charged with analyzing environmental and/or buildling material samples following contamination incident.

  3. Protocol for Detection of Yersinia pestis in Environmental ...

    EPA Pesticide Factsheets

    Methods Report This is the first ever open-access and detailed protocol available to all government departments and agencies, and their contractors to detect Yersinia pestis, the pathogen that causes plague, from multiple environmental sample types including water. Each analytical method includes sample processing procedure for each sample type in a step-by-step manner. It includes real-time PCR, traditional microbiological culture, and the Rapid Viability PCR (RV-PCR) analytical methods. For large volume water samples it also includes an ultra-filtration-based sample concentration procedure. Because of such a non-restrictive availability of this protocol to all government departments and agencies, and their contractors, the nation will now have increased laboratory capacity to analyze large number of samples during a wide-area plague incident.

  4. Effect of different analyte diffusion/adsorption protocols on SERS signals

    NASA Astrophysics Data System (ADS)

    Li, Ruoping; Petschek, Rolfe G.; Han, Junhe; Huang, Mingju

    2018-07-01

    The effect of different analyte diffusion/adsorption protocols was studied which is often overlooked in surface-enhanced Raman scattering (SERS) technique. Three protocols: highly concentrated dilution (HCD) protocol, half-half dilution (HHD) protocol and layered adsorption (LA) protocol were studied and the SERS substrates were monolayer films of 80 nm Ag nanoparticles (NPs) which were modified by polyvinylpyrrolidone. The diffusion/adsorption mechanisms were modelled using the diffusion equation and the electromagnetic field distribution of two adjacent Ag NPs was simulated by the finite-different time-domain method. All experimental data and theoretical analysis suggest that different diffusion/adsorption behaviour of analytes will cause different SERS signal enhancements. HHD protocol could produce the most uniform and reproducible samples, and the corresponding signal intensity of the analyte is the strongest. This study will help to understand and promote the use of SERS technique in quantitative analysis.

  5. Validation protocol of analytical procedures for quantification of drugs in polymeric systems for parenteral administration: dexamethasone phosphate disodium microparticles.

    PubMed

    Martín-Sabroso, Cristina; Tavares-Fernandes, Daniel Filipe; Espada-García, Juan Ignacio; Torres-Suárez, Ana Isabel

    2013-12-15

    In this work a protocol to validate analytical procedures for the quantification of drug substances formulated in polymeric systems that comprise both drug entrapped into the polymeric matrix (assay:content test) and drug released from the systems (assay:dissolution test) is developed. This protocol is applied to the validation two isocratic HPLC analytical procedures for the analysis of dexamethasone phosphate disodium microparticles for parenteral administration. Preparation of authentic samples and artificially "spiked" and "unspiked" samples is described. Specificity (ability to quantify dexamethasone phosphate disodium in presence of constituents of the dissolution medium and other microparticle constituents), linearity, accuracy and precision are evaluated, in the range from 10 to 50 μg mL(-1) in the assay:content test procedure and from 0.25 to 10 μg mL(-1) in the assay:dissolution test procedure. The robustness of the analytical method to extract drug from microparticles is also assessed. The validation protocol developed allows us to conclude that both analytical methods are suitable for their intended purpose, but the lack of proportionality of the assay:dissolution analytical method should be taken into account. The validation protocol designed in this work could be applied to the validation of any analytical procedure for the quantification of drugs formulated in controlled release polymeric microparticles. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Analytical Protocols for Analysis of Organic Molecules in Mars Analog Materials

    NASA Technical Reports Server (NTRS)

    Mahaffy, Paul R.; Brinkerhoff, W.; Buch, A.; Demick, J.; Glavin, D. P.

    2004-01-01

    A range of analytical techniques and protocols that might be applied b in situ investigations of martian fines, ices, and rock samples are evaluated by analysis of organic molecules m Mars analogues. These simulants 6om terrestrial (i.e. tephra from Hawaii) or extraterrestrial (meteoritic) samples are examined by pyrolysis gas chromatograph mass spectrometry (GCMS), organic extraction followed by chemical derivatization GCMS, and laser desorption mass spectrometry (LDMS). The combination of techniques imparts analysis breadth since each technique provides a unique analysis capability for Certain classes of organic molecules.

  7. Metabolic profiling of body fluids and multivariate data analysis.

    PubMed

    Trezzi, Jean-Pierre; Jäger, Christian; Galozzi, Sara; Barkovits, Katalin; Marcus, Katrin; Mollenhauer, Brit; Hiller, Karsten

    2017-01-01

    Metabolome analyses of body fluids are challenging due pre-analytical variations, such as pre-processing delay and temperature, and constant dynamical changes of biochemical processes within the samples. Therefore, proper sample handling starting from the time of collection up to the analysis is crucial to obtain high quality samples and reproducible results. A metabolomics analysis is divided into 4 main steps: 1) Sample collection, 2) Metabolite extraction, 3) Data acquisition and 4) Data analysis. Here, we describe a protocol for gas chromatography coupled to mass spectrometry (GC-MS) based metabolic analysis for biological matrices, especially body fluids. This protocol can be applied on blood serum/plasma, saliva and cerebrospinal fluid (CSF) samples of humans and other vertebrates. It covers sample collection, sample pre-processing, metabolite extraction, GC-MS measurement and guidelines for the subsequent data analysis. Advantages of this protocol include: •Robust and reproducible metabolomics results, taking into account pre-analytical variations that may occur during the sampling process•Small sample volume required•Rapid and cost-effective processing of biological samples•Logistic regression based determination of biomarker signatures for in-depth data analysis.

  8. The importance of quality control in validating concentrations ...

    EPA Pesticide Factsheets

    A national-scale survey of 247 contaminants of emerging concern (CECs), including organic and inorganic chemical compounds, and microbial contaminants, was conducted in source and treated drinking water samples from 25 treatment plants across the United States. Multiple methods were used to determine these CECs, including six analytical methods to measure 174 pharmaceuticals, personal care products, and pesticides. A three-component quality assurance/quality control (QA/QC) program was designed for the subset of 174 CECs which allowed us to assess and compare performances of the methods used. The three components included: 1) a common field QA/QC protocol and sample design, 2) individual investigator-developed method-specific QA/QC protocols, and 3) a suite of 46 method comparison analytes that were determined in two or more analytical methods. Overall method performance for the 174 organic chemical CECs was assessed by comparing spiked recoveries in reagent, source, and treated water over a two-year period. In addition to the 247 CECs reported in the larger drinking water study, another 48 pharmaceutical compounds measured did not consistently meet predetermined quality standards. Methodologies that did not seem suitable for these analytes are overviewed. The need to exclude analytes based on method performance demonstrates the importance of additional QA/QC protocols. This paper compares the method performance of six analytical methods used to measure 174 emer

  9. The importance of quality control in validating concentrations of contaminants of emerging concern in source and treated drinking water samples.

    PubMed

    Batt, Angela L; Furlong, Edward T; Mash, Heath E; Glassmeyer, Susan T; Kolpin, Dana W

    2017-02-01

    A national-scale survey of 247 contaminants of emerging concern (CECs), including organic and inorganic chemical compounds, and microbial contaminants, was conducted in source and treated drinking water samples from 25 treatment plants across the United States. Multiple methods were used to determine these CECs, including six analytical methods to measure 174 pharmaceuticals, personal care products, and pesticides. A three-component quality assurance/quality control (QA/QC) program was designed for the subset of 174 CECs which allowed us to assess and compare performances of the methods used. The three components included: 1) a common field QA/QC protocol and sample design, 2) individual investigator-developed method-specific QA/QC protocols, and 3) a suite of 46 method comparison analytes that were determined in two or more analytical methods. Overall method performance for the 174 organic chemical CECs was assessed by comparing spiked recoveries in reagent, source, and treated water over a two-year period. In addition to the 247 CECs reported in the larger drinking water study, another 48 pharmaceutical compounds measured did not consistently meet predetermined quality standards. Methodologies that did not seem suitable for these analytes are overviewed. The need to exclude analytes based on method performance demonstrates the importance of additional QA/QC protocols. Published by Elsevier B.V.

  10. LC-MS based analysis of endogenous steroid hormones in human hair.

    PubMed

    Gao, Wei; Kirschbaum, Clemens; Grass, Juliane; Stalder, Tobias

    2016-09-01

    The quantification of endogenous steroid hormone concentrations in hair is increasingly used as a method for obtaining retrospective information on long-term integrated hormone exposure. Several different analytical procedures have been employed for hair steroid analysis, with liquid chromatography-mass spectrometry (LC-MS) being recognized as a particularly powerful analytical tool. Several methodological aspects affect the performance of LC-MS systems for hair steroid analysis, including sample preparation and pretreatment, steroid extraction, post-incubation purification, LC methodology, ionization techniques and MS specifications. Here, we critically review the differential value of such protocol variants for hair steroid hormones analysis, focusing on both analytical quality and practical feasibility issues. Our results show that, when methodological challenges are adequately addressed, LC-MS protocols can not only yield excellent sensitivity and specificity but are also characterized by relatively simple sample processing and short run times. This makes LC-MS based hair steroid protocols particularly suitable as a high-quality option for routine application in research contexts requiring the processing of larger numbers of samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR LABORATORY ANALYSIS OF HAIR SAMPLES FOR MERCURY (RTI-L-1.0)

    EPA Science Inventory

    The purpose of this protocol is to provide guidelines for the analysis of hair samples for total mercury by cold vapor atomic fluorescence (CVAFS) spectrometry. This protocol describes the methodology and all other analytical aspects involved in the analysis. Keywords: hair; s...

  12. Heparin removal by ecteola-cellulose pre-treatment enables the use of plasma samples for accurate measurement of anti-Yellow fever virus neutralizing antibodies.

    PubMed

    Campi-Azevedo, Ana Carolina; Peruhype-Magalhães, Vanessa; Coelho-Dos-Reis, Jordana Grazziela; Costa-Pereira, Christiane; Yamamura, Anna Yoshida; Lima, Sheila Maria Barbosa de; Simões, Marisol; Campos, Fernanda Magalhães Freire; de Castro Zacche Tonini, Aline; Lemos, Elenice Moreira; Brum, Ricardo Cristiano; de Noronha, Tatiana Guimarães; Freire, Marcos Silva; Maia, Maria de Lourdes Sousa; Camacho, Luiz Antônio Bastos; Rios, Maria; Chancey, Caren; Romano, Alessandro; Domingues, Carla Magda; Teixeira-Carvalho, Andréa; Martins-Filho, Olindo Assis

    2017-09-01

    Technological innovations in vaccinology have recently contributed to bring about novel insights for the vaccine-induced immune response. While the current protocols that use peripheral blood samples may provide abundant data, a range of distinct components of whole blood samples are required and the different anticoagulant systems employed may impair some properties of the biological sample and interfere with functional assays. Although the interference of heparin in functional assays for viral neutralizing antibodies such as the functional plaque-reduction neutralization test (PRNT), considered the gold-standard method to assess and monitor the protective immunity induced by the Yellow fever virus (YFV) vaccine, has been well characterized, the development of pre-analytical treatments is still required for the establishment of optimized protocols. The present study intended to optimize and evaluate the performance of pre-analytical treatment of heparin-collected blood samples with ecteola-cellulose (ECT) to provide accurate measurement of anti-YFV neutralizing antibodies, by PRNT. The study was designed in three steps, including: I. Problem statement; II. Pre-analytical steps; III. Analytical steps. Data confirmed the interference of heparin on PRNT reactivity in a dose-responsive fashion. Distinct sets of conditions for ECT pre-treatment were tested to optimize the heparin removal. The optimized protocol was pre-validated to determine the effectiveness of heparin plasma:ECT treatment to restore the PRNT titers as compared to serum samples. The validation and comparative performance was carried out by using a large range of serum vs heparin plasma:ECT 1:2 paired samples obtained from unvaccinated and 17DD-YFV primary vaccinated subjects. Altogether, the findings support the use of heparin plasma:ECT samples for accurate measurement of anti-YFV neutralizing antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. The evaluation of an analytical protocol for the determination of substances in waste for hazard classification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hennebert, Pierre, E-mail: pierre.hennebert@ineris.fr; Papin, Arnaud; Padox, Jean-Marie

    Highlights: • Knowledge of wastes in substances will be necessary to assess HP1–HP15 hazard properties. • A new analytical protocol is proposed for this and tested by two service laboratories on 32 samples. • Sixty-three percentage of the samples have a satisfactory analytical balance between 90% and 110%. • Eighty-four percentage of the samples were classified identically (Seveso Directive) for their hazardousness by the two laboratories. • The method, in progress, is being normalized in France and is be proposed to CEN. - Abstract: The classification of waste as hazardous could soon be assessed in Europe using largely the hazardmore » properties of its constituents, according to the the Classification, Labelling and Packaging (CLP) regulation. Comprehensive knowledge of the component constituents of a given waste will therefore be necessary. An analytical protocol for determining waste composition is proposed, which includes using inductively coupled plasma (ICP) screening methods to identify major elements and gas chromatography/mass spectrometry (GC–MS) screening techniques to measure organic compounds. The method includes a gross or indicator measure of ‘pools’ of higher molecular weight organic substances that are taken to be less bioactive and less hazardous, and of unresolved ‘mass’ during the chromatography of volatile and semi-volatile compounds. The concentration of some elements and specific compounds that are linked to specific hazard properties and are subject to specific regulation (examples include: heavy metals, chromium(VI), cyanides, organo-halogens, and PCBs) are determined by classical quantitative analysis. To check the consistency of the analysis, the sum of the concentrations (including unresolved ‘pools’) should give a mass balance between 90% and 110%. Thirty-two laboratory samples comprising different industrial wastes (liquids and solids) were tested by two routine service laboratories, to give circa 7000 parameter results. Despite discrepancies in some parameters, a satisfactory sum of estimated or measured concentrations (analytical balance) of 90% was reached for 20 samples (63% of the overall total) during this first test exercise, with identified reasons for most of the unsatisfactory results. Regular use of this protocol (which is now included in the French legislation) has enabled service laboratories to reach a 90% mass balance for nearly all the solid samples tested, and most of liquid samples (difficulties were caused in some samples from polymers in solution and vegetable oil). The protocol is submitted to French and European normalization bodies (AFNOR and CEN) and further improvements are awaited.« less

  14. Characterizing Contamination and Assessing Exposure, Risk and Resilience

    EPA Pesticide Factsheets

    EPA supports its responders' ability to characterize site contamination by developing sampling protocols, sample preparation methods, and analytical methods for chemicals, biotoxins, microbial pathogens, and radiological agents.

  15. It's Time to Develop a New "Draft Test Protocol" for a Mars Sample Return Mission (or Two…).

    PubMed

    Rummel, John D; Kminek, Gerhard

    2018-04-01

    The last time NASA envisioned a sample return mission from Mars, the development of a protocol to support the analysis of the samples in a containment facility resulted in a "Draft Test Protocol" that outlined required preparations "for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth" (Rummel et al., 2002 ). This document comprised a specific protocol to be used to conduct a biohazard test for a returned martian sample, following the recommendations of the Space Studies Board of the US National Academy of Sciences. Given the planned launch of a sample-collecting and sample-caching rover (Mars 2020) in 2 years' time, and with a sample return planned for the end of the next decade, it is time to revisit the Draft Test Protocol to develop a sample analysis and biohazard test plan to meet the needs of these future missions. Key Words: Biohazard detection-Mars sample analysis-Sample receiving facility-Protocol-New analytical techniques-Robotic sample handling. Astrobiology 18, 377-380.

  16. Indoor Exposure Product Testing Protocols Version 2

    EPA Science Inventory

    EPA’s Office of Pollution Prevention and Toxics (OPPT) has developed a set of ten indoor exposure testing protocols intended to provide information on the purpose of the testing, general description of the sampling and analytical procedures, and references for tests that will be ...

  17. Protocols for the analytical characterization of therapeutic monoclonal antibodies. II - Enzymatic and chemical sample preparation.

    PubMed

    Bobaly, Balazs; D'Atri, Valentina; Goyon, Alexandre; Colas, Olivier; Beck, Alain; Fekete, Szabolcs; Guillarme, Davy

    2017-08-15

    The analytical characterization of therapeutic monoclonal antibodies and related proteins usually incorporates various sample preparation methodologies. Indeed, quantitative and qualitative information can be enhanced by simplifying the sample, thanks to the removal of sources of heterogeneity (e.g. N-glycans) and/or by decreasing the molecular size of the tested protein by enzymatic or chemical fragmentation. These approaches make the sample more suitable for chromatographic and mass spectrometric analysis. Structural elucidation and quality control (QC) analysis of biopharmaceutics are usually performed at intact, subunit and peptide levels. In this paper, general sample preparation approaches used to attain peptide, subunit and glycan level analysis are overviewed. Protocols are described to perform tryptic proteolysis, IdeS and papain digestion, reduction as well as deglycosylation by PNGase F and EndoS2 enzymes. Both historical and modern sample preparation methods were compared and evaluated using rituximab and trastuzumab, two reference therapeutic mAb products approved by Food and Drug Administration (FDA) and European Medicines Agency (EMA). The described protocols may help analysts to develop sample preparation methods in the field of therapeutic protein analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. An automated baseline correction protocol for infrared spectra of atmospheric aerosols collected on polytetrafluoroethylene (Teflon) filters

    NASA Astrophysics Data System (ADS)

    Kuzmiakova, Adele; Dillner, Ann M.; Takahama, Satoshi

    2016-06-01

    A growing body of research on statistical applications for characterization of atmospheric aerosol Fourier transform infrared (FT-IR) samples collected on polytetrafluoroethylene (PTFE) filters (e.g., Russell et al., 2011; Ruthenburg et al., 2014) and a rising interest in analyzing FT-IR samples collected by air quality monitoring networks call for an automated PTFE baseline correction solution. The existing polynomial technique (Takahama et al., 2013) is not scalable to a project with a large number of aerosol samples because it contains many parameters and requires expert intervention. Therefore, the question of how to develop an automated method for baseline correcting hundreds to thousands of ambient aerosol spectra given the variability in both environmental mixture composition and PTFE baselines remains. This study approaches the question by detailing the statistical protocol, which allows for the precise definition of analyte and background subregions, applies nonparametric smoothing splines to reproduce sample-specific PTFE variations, and integrates performance metrics from atmospheric aerosol and blank samples alike in the smoothing parameter selection. Referencing 794 atmospheric aerosol samples from seven Interagency Monitoring of PROtected Visual Environment (IMPROVE) sites collected during 2011, we start by identifying key FT-IR signal characteristics, such as non-negative absorbance or analyte segment transformation, to capture sample-specific transitions between background and analyte. While referring to qualitative properties of PTFE background, the goal of smoothing splines interpolation is to learn the baseline structure in the background region to predict the baseline structure in the analyte region. We then validate the model by comparing smoothing splines baseline-corrected spectra with uncorrected and polynomial baseline (PB)-corrected equivalents via three statistical applications: (1) clustering analysis, (2) functional group quantification, and (3) thermal optical reflectance (TOR) organic carbon (OC) and elemental carbon (EC) predictions. The discrepancy rate for a four-cluster solution is 10 %. For all functional groups but carboxylic COH the discrepancy is ≤ 10 %. Performance metrics obtained from TOR OC and EC predictions (R2 ≥ 0.94 %, bias ≤ 0.01 µg m-3, and error ≤ 0.04 µg m-3) are on a par with those obtained from uncorrected and PB-corrected spectra. The proposed protocol leads to visually and analytically similar estimates as those generated by the polynomial method. More importantly, the automated solution allows us and future users to evaluate its analytical reproducibility while minimizing reducible user bias. We anticipate the protocol will enable FT-IR researchers and data analysts to quickly and reliably analyze a large amount of data and connect them to a variety of available statistical learning methods to be applied to analyte absorbances isolated in atmospheric aerosol samples.

  19. Molecular detection of Borrelia burgdorferi sensu lato – An analytical comparison of real-time PCR protocols from five different Scandinavian laboratories

    PubMed Central

    Faller, Maximilian; Wilhelmsson, Peter; Kjelland, Vivian; Andreassen, Åshild; Dargis, Rimtas; Quarsten, Hanne; Dessau, Ram; Fingerle, Volker; Margos, Gabriele; Noraas, Sølvi; Ornstein, Katharina; Petersson, Ann-Cathrine; Matussek, Andreas; Lindgren, Per-Eric; Henningsson, Anna J.

    2017-01-01

    Introduction Lyme borreliosis (LB) is the most common tick transmitted disease in Europe. The diagnosis of LB today is based on the patient´s medical history, clinical presentation and laboratory findings. The laboratory diagnostics are mainly based on antibody detection, but in certain conditions molecular detection by polymerase chain reaction (PCR) may serve as a complement. Aim The purpose of this study was to evaluate the analytical sensitivity, analytical specificity and concordance of eight different real-time PCR methods at five laboratories in Sweden, Norway and Denmark. Method Each participating laboratory was asked to analyse three different sets of samples (reference panels; all blinded) i) cDNA extracted and transcribed from water spiked with cultured Borrelia strains, ii) cerebrospinal fluid spiked with cultured Borrelia strains, and iii) DNA dilution series extracted from cultured Borrelia and relapsing fever strains. The results and the method descriptions of each laboratory were systematically evaluated. Results and conclusions The analytical sensitivities and the concordance between the eight protocols were in general high. The concordance was especially high between the protocols using 16S rRNA as the target gene, however, this concordance was mainly related to cDNA as the type of template. When comparing cDNA and DNA as the type of template the analytical sensitivity was in general higher for the protocols using DNA as template regardless of the use of target gene. The analytical specificity for all eight protocols was high. However, some protocols were not able to detect Borrelia spielmanii, Borrelia lusitaniae or Borrelia japonica. PMID:28937997

  20. Hanford analytical sample projections FY 1998--FY 2002

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joyce, S.M.

    1998-02-12

    Analytical Services projections are compiled for the Hanford site based on inputs from the major programs for the years 1998 through 2002. Projections are categorized by radiation level, protocol, sample matrix and program. Analyses requirements are also presented. This document summarizes the Hanford sample projections for fiscal years 1998 to 2002. Sample projections are based on inputs submitted to Analytical Services covering Environmental Restoration, Tank Waste Remediation Systems (TWRS), Solid Waste, Liquid Effluents, Spent Nuclear Fuels, Transition Projects, Site Monitoring, Industrial Hygiene, Analytical Services and miscellaneous Hanford support activities. In addition, details on laboratory scale technology (development) work, Sample Management,more » and Data Management activities are included. This information will be used by Hanford Analytical Services (HAS) and the Sample Management Working Group (SMWG) to assure that laboratories and resources are available and effectively utilized to meet these documented needs.« less

  1. Glycan characterization of the NIST RM monoclonal antibody using a total analytical solution: From sample preparation to data analysis.

    PubMed

    Hilliard, Mark; Alley, William R; McManus, Ciara A; Yu, Ying Qing; Hallinan, Sinead; Gebler, John; Rudd, Pauline M

    Glycosylation is an important attribute of biopharmaceutical products to monitor from development through production. However, glycosylation analysis has traditionally been a time-consuming process with long sample preparation protocols and manual interpretation of the data. To address the challenges associated with glycan analysis, we developed a streamlined analytical solution that covers the entire process from sample preparation to data analysis. In this communication, we describe the complete analytical solution that begins with a simplified and fast N-linked glycan sample preparation protocol that can be completed in less than 1 hr. The sample preparation includes labelling with RapiFluor-MS tag to improve both fluorescence (FLR) and mass spectral (MS) sensitivities. Following HILIC-UPLC/FLR/MS analyses, the data are processed and a library search based on glucose units has been included to expedite the task of structural assignment. We then applied this total analytical solution to characterize the glycosylation of the NIST Reference Material mAb 8761. For this glycoprotein, we confidently identified 35 N-linked glycans and all three major classes, high mannose, complex, and hybrid, were present. The majority of the glycans were neutral and fucosylated; glycans featuring N-glycolylneuraminic acid and those with two galactoses connected via an α1,3-linkage were also identified.

  2. Analytical platform for metabolome analysis of microbial cells using methyl chloroformate derivatization followed by gas chromatography-mass spectrometry.

    PubMed

    Smart, Kathleen F; Aggio, Raphael B M; Van Houtte, Jeremy R; Villas-Bôas, Silas G

    2010-09-01

    This protocol describes an analytical platform for the analysis of intra- and extracellular metabolites of microbial cells (yeast, filamentous fungi and bacteria) using gas chromatography-mass spectrometry (GC-MS). The protocol is subdivided into sampling, sample preparation, chemical derivatization of metabolites, GC-MS analysis and data processing and analysis. This protocol uses two robust quenching methods for microbial cultures, the first of which, cold glycerol-saline quenching, causes reduced leakage of intracellular metabolites, thus allowing a more reliable separation of intra- and extracellular metabolites with simultaneous stopping of cell metabolism. The second, fast filtration, is specifically designed for quenching filamentous micro-organisms. These sampling techniques are combined with an easy sample-preparation procedure and a fast chemical derivatization reaction using methyl chloroformate. This reaction takes place at room temperature, in aqueous medium, and is less prone to matrix effect compared with other derivatizations. This protocol takes an average of 10 d to complete and enables the simultaneous analysis of hundreds of metabolites from the central carbon metabolism (amino and nonamino organic acids, phosphorylated organic acids and fatty acid intermediates) using an in-house MS library and a data analysis pipeline consisting of two free software programs (Automated Mass Deconvolution and Identification System (AMDIS) and R).

  3. 21 CFR 314.50 - Content and format of an application.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... the protocol and a description of the statistical analyses used to evaluate the study. If the study... application: (i) Three copies of the analytical procedures and related descriptive information contained in... the samples and to validate the applicant's analytical procedures. The related descriptive information...

  4. 21 CFR 314.50 - Content and format of an application.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... the protocol and a description of the statistical analyses used to evaluate the study. If the study... application: (i) Three copies of the analytical procedures and related descriptive information contained in... the samples and to validate the applicant's analytical procedures. The related descriptive information...

  5. 21 CFR 314.50 - Content and format of an application.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... the protocol and a description of the statistical analyses used to evaluate the study. If the study... application: (i) Three copies of the analytical procedures and related descriptive information contained in... the samples and to validate the applicant's analytical procedures. The related descriptive information...

  6. 21 CFR 314.50 - Content and format of an application.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... the protocol and a description of the statistical analyses used to evaluate the study. If the study... application: (i) Three copies of the analytical procedures and related descriptive information contained in... the samples and to validate the applicant's analytical procedures. The related descriptive information...

  7. 21 CFR 314.50 - Content and format of an application.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... the protocol and a description of the statistical analyses used to evaluate the study. If the study... application: (i) Three copies of the analytical procedures and related descriptive information contained in... the samples and to validate the applicant's analytical procedures. The related descriptive information...

  8. HYDROLYSIS OF MTBE IN GROUND WATER SAMPLES PRESERVED WITIH HYDROCHLORIC ACID

    EPA Science Inventory

    Conventional sampling and analytical protocols have poor sensitivity for fuel oxygenates that are alcohols, such as TBA. Because alcohols tend to stay with the water samples, they are not efficiently transferred to the gas chromatograph for separation and analysis. A common tec...

  9. Evaluation of Aspergillus PCR protocols for testing serum specimens.

    PubMed

    White, P Lewis; Mengoli, Carlo; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Finnstrom, Niklas; Klingspor, Lena; Melchers, Willem J G; McCulloch, Elaine; Barnes, Rosemary A; Donnelly, J Peter; Loeffler, Juergen

    2011-11-01

    A panel of human serum samples spiked with various amounts of Aspergillus fumigatus genomic DNA was distributed to 23 centers within the European Aspergillus PCR Initiative to determine analytical performance of PCR. Information regarding specific methodological components and PCR performance was requested. The information provided was made anonymous, and meta-regression analysis was performed to determine any procedural factors that significantly altered PCR performance. Ninety-seven percent of protocols were able to detect a threshold of 10 genomes/ml on at least one occasion, with 83% of protocols reproducibly detecting this concentration. Sensitivity and specificity were 86.1% and 93.6%, respectively. Positive associations between sensitivity and the use of larger sample volumes, an internal control PCR, and PCR targeting the internal transcribed spacer (ITS) region were shown. Negative associations between sensitivity and the use of larger elution volumes (≥100 μl) and PCR targeting the mitochondrial genes were demonstrated. Most Aspergillus PCR protocols used to test serum generate satisfactory analytical performance. Testing serum requires less standardization, and the specific recommendations shown in this article will only improve performance.

  10. Evaluation of Aspergillus PCR Protocols for Testing Serum Specimens▿†

    PubMed Central

    White, P. Lewis; Mengoli, Carlo; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Finnstrom, Niklas; Klingspor, Lena; Melchers, Willem J. G.; McCulloch, Elaine; Barnes, Rosemary A.; Donnelly, J. Peter; Loeffler, Juergen

    2011-01-01

    A panel of human serum samples spiked with various amounts of Aspergillus fumigatus genomic DNA was distributed to 23 centers within the European Aspergillus PCR Initiative to determine analytical performance of PCR. Information regarding specific methodological components and PCR performance was requested. The information provided was made anonymous, and meta-regression analysis was performed to determine any procedural factors that significantly altered PCR performance. Ninety-seven percent of protocols were able to detect a threshold of 10 genomes/ml on at least one occasion, with 83% of protocols reproducibly detecting this concentration. Sensitivity and specificity were 86.1% and 93.6%, respectively. Positive associations between sensitivity and the use of larger sample volumes, an internal control PCR, and PCR targeting the internal transcribed spacer (ITS) region were shown. Negative associations between sensitivity and the use of larger elution volumes (≥100 μl) and PCR targeting the mitochondrial genes were demonstrated. Most Aspergillus PCR protocols used to test serum generate satisfactory analytical performance. Testing serum requires less standardization, and the specific recommendations shown in this article will only improve performance. PMID:21940479

  11. Updated operational protocols for the U.S. Geological Survey Precipitation Chemistry Quality Assurance Project in support of the National Atmospheric Deposition Program

    USGS Publications Warehouse

    Wetherbee, Gregory A.; Martin, RoseAnn

    2017-02-06

    The U.S. Geological Survey Branch of Quality Systems operates the Precipitation Chemistry Quality Assurance Project (PCQA) for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN) and National Atmospheric Deposition Program/Mercury Deposition Network (NADP/MDN). Since 1978, various programs have been implemented by the PCQA to estimate data variability and bias contributed by changing protocols, equipment, and sample submission schemes within NADP networks. These programs independently measure the field and laboratory components which contribute to the overall variability of NADP wet-deposition chemistry and precipitation depth measurements. The PCQA evaluates the quality of analyte-specific chemical analyses from the two, currently (2016) contracted NADP laboratories, Central Analytical Laboratory and Mercury Analytical Laboratory, by comparing laboratory performance among participating national and international laboratories. Sample contamination and stability are evaluated for NTN and MDN by using externally field-processed blank samples provided by the Branch of Quality Systems. A colocated sampler program evaluates the overall variability of NTN measurements and bias between dissimilar precipitation gages and sample collectors.This report documents historical PCQA operations and general procedures for each of the external quality-assurance programs from 2007 to 2016.

  12. Geochemical and mineralogical data for soils of the conterminous United States

    USGS Publications Warehouse

    Smith, David B.; Cannon, William F.; Woodruff, Laurel G.; Solano, Federico; Kilburn, James E.; Fey, David L.

    2013-01-01

    In 2007, the U.S. Geological Survey initiated a low-density (1 site per 1,600 square kilometers, 4,857 sites) geochemical and mineralogical survey of soils of the conterminous United States as part of the North American Soil Geochemical Landscapes Project. Sampling and analytical protocols were developed at a workshop in 2003, and pilot studies were conducted from 2004 to 2007 to test and refine these recommended protocols. The final sampling protocol for the national-scale survey included, at each site, a sample from a depth of 0 to 5 centimeters, a composite of the soil A horizon, and a deeper sample from the soil C horizon or, if the top of the C horizon was at a depth greater than 1 meter, from a depth of approximately 80–100 centimeters. The <2-millimeter fraction of each sample was analyzed for a suite of 45 major and trace elements by methods that yield the total or near-total elemental content. The major mineralogical components in the samples from the soil A and C horizons were determined by a quantitative X-ray diffraction method using Rietveld refinement. Sampling in the conterminous United States was completed in 2010, with chemical and mineralogical analyses completed in May 2013. The resulting dataset provides an estimate of the abundance and spatial distribution of chemical elements and minerals in soils of the conterminous United States and represents a baseline for soil geochemistry and mineralogy against which future changes may be recognized and quantified. This report (1) describes the sampling, sample preparation, and analytical methods used; (2) gives details of the quality control protocols used to monitor the quality of chemical and mineralogical analyses over approximately six years; and (3) makes available the soil geochemical and mineralogical data in downloadable tables.

  13. Assessment of sample preservation techniques for pharmaceuticals, personal care products, and steroids in surface and drinking water.

    PubMed

    Vanderford, Brett J; Mawhinney, Douglas B; Trenholm, Rebecca A; Zeigler-Holady, Janie C; Snyder, Shane A

    2011-02-01

    Proper collection and preservation techniques are necessary to ensure sample integrity and maintain the stability of analytes until analysis. Data from improperly collected and preserved samples could lead to faulty conclusions and misinterpretation of the occurrence and fate of the compounds being studied. Because contaminants of emerging concern, such as pharmaceuticals and personal care products (PPCPs) and steroids, generally occur in surface and drinking water at ng/L levels, these compounds in particular require such protocols to accurately assess their concentrations. In this study, sample bottle types, residual oxidant quenching agents, preservation agents, and hold times were assessed for 21 PPCPs and steroids in surface water and finished drinking water. Amber glass bottles were found to have the least effect on target analyte concentrations, while high-density polyethylene bottles had the most impact. Ascorbic acid, sodium thiosulfate, and sodium sulfite were determined to be acceptable quenching agents and preservation with sodium azide at 4 °C led to the stability of the most target compounds. A combination of amber glass bottles, ascorbic acid, and sodium azide preserved analyte concentrations for 28 days in the tested matrices when held at 4 °C. Samples without a preservation agent were determined to be stable for all but two of the analytes when stored in amber glass bottles at 4 °C for 72 h. Results suggest that if improper protocols are utilized, reported concentrations of target PPCPs and steroids may be inaccurate.

  14. HYDROLYSIS OF MTBE TO TBA IN GROUND WATER SAMPLES WITH HYDROCHLORIC ACID

    EPA Science Inventory

    Conventional sampling and analytical protocols have poor sensitivity for fuel oxygenates that are alcohols, such as tert-butyl alcohol (TBA). Because alcohols are miscible or highly soluble in water, alcohols are not efficiently transferred to the gas chromatograph for analysis....

  15. Plant gum identification in historic artworks

    PubMed Central

    Granzotto, Clara; Arslanoglu, Julie; Rolando, Christian; Tokarski, Caroline

    2017-01-01

    We describe an integrated and straightforward new analytical protocol that identifies plant gums from various sample sources including cultural heritage. Our approach is based on the identification of saccharidic fingerprints using mass spectrometry following controlled enzymatic hydrolysis. We developed an enzyme cocktail suitable for plant gums of unknown composition. Distinctive MS profiles of gums such as arabic, cherry and locust-bean gums were successfully identified. A wide range of oligosaccharidic combinations of pentose, hexose, deoxyhexose and hexuronic acid were accurately identified in gum arabic whereas cherry and locust bean gums showed respectively PentxHexy and Hexn profiles. Optimized for low sample quantities, the analytical protocol was successfully applied to contemporary and historic samples including ‘Colour Box Charles Roberson & Co’ dating 1870s and drawings from the American painter Arthur Dove (1880–1946). This is the first time that a gum is accurately identified in a cultural heritage sample using structural information. Furthermore, this methodology is applicable to other domains (food, cosmetic, pharmaceutical, biomedical). PMID:28425501

  16. Pre-analytical effects of blood sampling and handling in quantitative immunoassays for rheumatoid arthritis.

    PubMed

    Zhao, Xiaoyan; Qureshi, Ferhan; Eastman, P Scott; Manning, William C; Alexander, Claire; Robinson, William H; Hesterberg, Lyndal K

    2012-04-30

    Variability in pre-analytical blood sampling and handling can significantly impact results obtained in quantitative immunoassays. Understanding the impact of these variables is critical for accurate quantification and validation of biomarker measurements. Particularly, in the design and execution of large clinical trials, even small differences in sample processing and handling can have dramatic effects in analytical reliability, results interpretation, trial management and outcome. The effects of two common blood sampling methods (serum vs. plasma) and two widely-used serum handling methods (on the clot with ambient temperature shipping, "traditional", vs. centrifuged with cold chain shipping, "protocol") on protein and autoantibody concentrations were examined. Matched serum and plasma samples were collected from 32 rheumatoid arthritis (RA) patients representing a wide range of disease activity status. Additionally, a set of matched serum samples with two sample handling methods was collected. One tube was processed per manufacturer's instructions and shipped overnight on cold packs (protocol). The matched tube, without prior centrifugation, was simultaneously shipped overnight at ambient temperatures (traditional). Upon delivery, the traditional tube was centrifuged. All samples were subsequently aliquoted and frozen prior to analysis of protein and autoantibody biomarkers. Median correlation between paired serum and plasma across all autoantibody assays was 0.99 (0.98-1.00) with a median % difference of -3.3 (-7.5 to 6.0). In contrast, observed protein biomarker concentrations were significantly affected by sample types, with median correlation of 0.99 (0.33-1.00) and a median % difference of -10 (-55 to 23). When the two serum collection/handling methods were compared, the median correlation between paired samples for autoantibodies was 0.99 (0.91-1.00) with a median difference of 4%. In contrast, significant increases were observed in protein biomarker concentrations among certain biomarkers in samples processed with the 'traditional' method. Autoantibody quantification appears robust to both sample type (plasma vs. serum) and pre-analytical sample collection/handling methods (protocol vs. traditional). In contrast, for non-antibody protein biomarker concentrations, sample type had a significant impact; plasma samples generally exhibit decreased protein biomarker concentrations relative to serum. Similarly, sample handling significantly impacted the variability of protein biomarker concentrations. When biomarker concentrations are combined algorithmically into a single test score such as a multi-biomarker disease activity test for rheumatoid arthritis (MBDA), changes in protein biomarker concentrations may result in a bias of the score. These results illustrate the importance of characterizing pre-analytical methodology, sample type, sample processing and handling procedures for clinical testing in order to ensure test accuracy. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Standardization and optimization of fluorescence in situ hybridization (FISH) for HER-2 assessment in breast cancer: A single center experience.

    PubMed

    Bogdanovska-Todorovska, Magdalena; Petrushevska, Gordana; Janevska, Vesna; Spasevska, Liljana; Kostadinova-Kunovska, Slavica

    2018-05-20

    Accurate assessment of human epidermal growth factor receptor 2 (HER-2) is crucial in selecting patients for targeted therapy. Commonly used methods for HER-2 testing are immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH). Here we presented the implementation, optimization and standardization of two FISH protocols using breast cancer samples and assessed the impact of pre-analytical and analytical factors on HER-2 testing. Formalin fixed paraffin embedded (FFPE) tissue samples from 70 breast cancer patients were tested for HER-2 using PathVysion™ HER-2 DNA Probe Kit and two different paraffin pretreatment kits, Vysis/Abbott Paraffin Pretreatment Reagent Kit (40 samples) and DAKO Histology FISH Accessory Kit (30 samples). The concordance between FISH and IHC results was determined. Pre-analytical and analytical factors (i.e., fixation, baking, digestion, and post-hybridization washing) affected the efficiency and quality of hybridization. The overall hybridization success in our study was 98.6% (69/70); the failure rate was 1.4%. The DAKO pretreatment kit was more time-efficient and resulted in more uniform signals that were easier to interpret, compared to the Vysis/Abbott kit. The overall concordance between IHC and FISH was 84.06%, kappa coefficient 0.5976 (p < 0.0001). The greatest discordance (82%) between IHC and FISH was observed in IHC 2+ group. A standardized FISH protocol for HER-2 assessment, with high hybridization efficiency, is necessary due to variability in tissue processing and individual tissue characteristics. Differences in the pre-analytical and analytical steps can affect the hybridization quality and efficiency. The use of DAKO pretreatment kit is time-saving and cost-effective.

  18. Looking for new biomarkers of skin wound vitality with a cytokine-based multiplex assay: preliminary study.

    PubMed

    Peyron, Pierre-Antoine; Baccino, Éric; Nagot, Nicolas; Lehmann, Sylvain; Delaby, Constance

    2017-02-01

    Determination of skin wound vitality is an important issue in forensic practice. No reliable biomarker currently exists. Quantification of inflammatory cytokines in injured skin with MSD ® technology is an innovative and promising approach. This preliminary study aims to develop a protocol for the preparation and the analysis of skin samples. Samples from ante mortem wounds, post mortem wounds, and intact skin ("control samples") were taken from corpses at the autopsy. After an optimization of the pre-analytical protocol had been performed in terms of skin homogeneisation and proteic extraction, the concentration of TNF-α was measured in each sample with the MSD ® approach. Then five other cytokines of interest (IL-1β, IL-6, IL-10, IL-12p70 and IFN-γ) were simultaneously quantified with a MSD ® multiplex assay. The optimal pre-analytical conditions consist in a proteic extraction from a 6 mm diameter skin sample, in a PBS buffer with triton 0,05%. Our results show the linearity and the reproductibility of the TNF-α quantification with MSD ® , and an inter- and intra-individual variability of the concentrations of proteins. The MSD ® multiplex assay is likely to detect differential skin concentrations for each cytokine of interest. This preliminary study was used to develop and optimize the pre-analytical and analytical conditions of the MSD ® method using injured and healthy skin samples, for the purpose of looking for and identifying the cytokine, or the set of cytokines, that may be biomarkers of skin wound vitality.

  19. A review of blood sample handling and pre-processing for metabolomics studies.

    PubMed

    Hernandes, Vinicius Veri; Barbas, Coral; Dudzik, Danuta

    2017-09-01

    Metabolomics has been found to be applicable to a wide range of clinical studies, bringing a new era for improving clinical diagnostics, early disease detection, therapy prediction and treatment efficiency monitoring. A major challenge in metabolomics, particularly untargeted studies, is the extremely diverse and complex nature of biological specimens. Despite great advances in the field there still exist fundamental needs for considering pre-analytical variability that can introduce bias to the subsequent analytical process and decrease the reliability of the results and moreover confound final research outcomes. Many researchers are mainly focused on the instrumental aspects of the biomarker discovery process, and sample related variables sometimes seem to be overlooked. To bridge the gap, critical information and standardized protocols regarding experimental design and sample handling and pre-processing are highly desired. Characterization of a range variation among sample collection methods is necessary to prevent results misinterpretation and to ensure that observed differences are not due to an experimental bias caused by inconsistencies in sample processing. Herein, a systematic discussion of pre-analytical variables affecting metabolomics studies based on blood derived samples is performed. Furthermore, we provide a set of recommendations concerning experimental design, collection, pre-processing procedures and storage conditions as a practical review that can guide and serve for the standardization of protocols and reduction of undesirable variation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Time- and cost-saving apparatus for analytical sample filtration

    Treesearch

    William R. Kenealy; Joseph C. Destree

    2005-01-01

    Simple and cost-effective protocols were developed for removing particulates from samples prior to analysis by high performance liquid chromatography and gas chromatography. A filter and vial holder were developed for use with a 96-well filtration plate. The device saves preparation time and costs.

  1. Microextraction by packed sorbent: an emerging, selective and high-throughput extraction technique in bioanalysis.

    PubMed

    Pereira, Jorge; Câmara, José S; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2014-06-01

    Sample preparation is an important analytical step regarding the isolation and concentration of desired components from complex matrices and greatly influences their reliable and accurate analysis and data quality. It is the most labor-intensive and error-prone process in analytical methodology and, therefore, may influence the analytical performance of the target analytes quantification. Many conventional sample preparation methods are relatively complicated, involving time-consuming procedures and requiring large volumes of organic solvents. Recent trends in sample preparation include miniaturization, automation, high-throughput performance, on-line coupling with analytical instruments and low-cost operation through extremely low volume or no solvent consumption. Micro-extraction techniques, such as micro-extraction by packed sorbent (MEPS), have these advantages over the traditional techniques. This paper gives an overview of MEPS technique, including the role of sample preparation in bioanalysis, the MEPS description namely MEPS formats (on- and off-line), sorbents, experimental and protocols, factors that affect the MEPS performance, and the major advantages and limitations of MEPS compared with other sample preparation techniques. We also summarize MEPS recent applications in bioanalysis. Copyright © 2014 John Wiley & Sons, Ltd.

  2. A new tool for the evaluation of the analytical procedure: Green Analytical Procedure Index.

    PubMed

    Płotka-Wasylka, J

    2018-05-01

    A new means for assessing analytical protocols relating to green analytical chemistry attributes has been developed. The new tool, called GAPI (Green Analytical Procedure Index), evaluates the green character of an entire analytical methodology, from sample collection to final determination, and was created using such tools as the National Environmental Methods Index (NEMI) or Analytical Eco-Scale to provide not only general but also qualitative information. In GAPI, a specific symbol with five pentagrams can be used to evaluate and quantify the environmental impact involved in each step of an analytical methodology, mainly from green through yellow to red depicting low, medium to high impact, respectively. The proposed tool was used to evaluate analytical procedures applied in the determination of biogenic amines in wine samples, and polycyclic aromatic hydrocarbon determination by EPA methods. GAPI tool not only provides an immediately perceptible perspective to the user/reader but also offers exhaustive information on evaluated procedures. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--NHEXAS FILTER HANDLING, WEIGHING AND ARCHIVING PROCEDURES FOR AEROSOL SAMPLES (RTI/ACS-AP-209-011)

    EPA Science Inventory

    This protocol describes the procedures for weighing, handling, and archiving aerosol filters and for managing the associated analytical and quality assurance data. Filter samples were weighed for aerosol mass at RTI laboratory, with only the automated field sampling data transfer...

  4. Determination of hydrazine in drinking water: Development and multivariate optimization of a rapid and simple solid phase microextraction-gas chromatography-triple quadrupole mass spectrometry protocol.

    PubMed

    Gionfriddo, Emanuela; Naccarato, Attilio; Sindona, Giovanni; Tagarelli, Antonio

    2014-07-04

    In this work, the capabilities of solid phase microextraction were exploited in a fully optimized SPME-GC-QqQ-MS analytical approach for hydrazine assay. A rapid and easy method was obtained by a simple derivatization reaction with propyl chloroformate and pyridine carried out directly in water samples, followed by automated SPME analysis in the same vial without further sample handling. The affinity of the different derivatized compounds obtained towards five commercially available SPME coatings was evaluated, in order to achieve the best extraction efficiency. GC analyses were carried out using a GC-QqQ-MS instrument in selected reaction monitoring (SRM) acquisition mode which has allowed the achievement of high specificity by selecting appropriate precursor-product ion couples improving the capability in analyte identification. The multivariate approach of experimental design was crucial in order to optimize derivatization reaction, SPME process and tandem mass spectrometry parameters. Accuracy of the proposed protocol, tested at 60, 200 and 800 ng L(-1), provided satisfactory values (114.2%, 83.6% and 98.6%, respectively), whereas precision (RSD%) at the same concentration levels were of 10.9%, 7.9% and 7.7% respectively. Limit of detection and quantification of 4.4 and 8.3 ng L(-1) were obtained. The reliable application of the proposed protocol to real drinking water samples confirmed its capability to be used as analytical tool for routine analyses. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Technical pre-analytical effects on the clinical biochemistry of Atlantic salmon (Salmo salar L.).

    PubMed

    Braceland, M; Houston, K; Ashby, A; Matthews, C; Haining, H; Rodger, H; Eckersall, P D

    2017-01-01

    Clinical biochemistry has long been utilized in human and veterinary medicine as a vital diagnostic tool, but despite occasional studies showing its usefulness in monitoring health status in Atlantic salmon (Salmo salar L.), it has not yet been widely utilized within the aquaculture industry. This is due, in part, to a lack of an agreed protocol for collection and processing of blood prior to analysis. Moreover, while the analytical phase of clinical biochemistry is well controlled, there is a growing understanding that technical pre-analytical variables can influence analyte concentrations or activities. In addition, post-analytical interpretation of treatment effects is variable in the literature, thus making the true effect of sample treatment hard to evaluate. Therefore, a number of pre-analytical treatments have been investigated to examine their effect on analyte concentrations and activities. In addition, reference ranges for salmon plasma biochemical analytes have been established to inform veterinary practitioners and the aquaculture industry of the importance of clinical biochemistry in health and disease monitoring. Furthermore, a standardized protocol for blood collection has been proposed. © 2016 The Authors Journal of Fish Diseases Published by John Wiley & Sons Ltd.

  6. Addressing the need for biomarker liquid chromatography/mass spectrometry assays: a protocol for effective method development for the bioanalysis of endogenous compounds in cerebrospinal fluid.

    PubMed

    Benitex, Yulia; McNaney, Colleen A; Luchetti, David; Schaeffer, Eric; Olah, Timothy V; Morgan, Daniel G; Drexler, Dieter M

    2013-08-30

    Research on disorders of the central nervous system (CNS) has shown that an imbalance in the levels of specific endogenous neurotransmitters may underlie certain CNS diseases. These alterations in neurotransmitter levels may provide insight into pathophysiology, but can also serve as disease and pharmacodynamic biomarkers. To measure these potential biomarkers in vivo, the relevant sample matrix is cerebrospinal fluid (CSF), which is in equilibrium with the brain's interstitial fluid and circulates through the ventricular system of the brain and spinal cord. Accurate analysis of these potential biomarkers can be challenging due to low CSF sample volume, low analyte levels, and potential interferences from other endogenous compounds. A protocol has been established for effective method development of bioanalytical assays for endogenous compounds in CSF. Database searches and standard-addition experiments are employed to qualify sample preparation and specificity of the detection thus evaluating accuracy and precision. This protocol was applied to the study of the histaminergic neurotransmitter system and the analysis of histamine and its metabolite 1-methylhistamine in rat CSF. The protocol resulted in a specific and sensitive novel method utilizing pre-column derivatization ultra high performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS), which is also capable of separating an endogenous interfering compound, identified as taurine, from the analytes of interest. Copyright © 2013 John Wiley & Sons, Ltd.

  7. Simple and Sensitive Paper-Based Device Coupling Electrochemical Sample Pretreatment and Colorimetric Detection.

    PubMed

    Silva, Thalita G; de Araujo, William R; Muñoz, Rodrigo A A; Richter, Eduardo M; Santana, Mário H P; Coltro, Wendell K T; Paixão, Thiago R L C

    2016-05-17

    We report the development of a simple, portable, low-cost, high-throughput visual colorimetric paper-based analytical device for the detection of procaine in seized cocaine samples. The interference of most common cutting agents found in cocaine samples was verified, and a novel electrochemical approach was used for sample pretreatment in order to increase the selectivity. Under the optimized experimental conditions, a linear analytical curve was obtained for procaine concentrations ranging from 5 to 60 μmol L(-1), with a detection limit of 0.9 μmol L(-1). The accuracy of the proposed method was evaluated using seized cocaine samples and an addition and recovery protocol.

  8. VALIDATION OF STANDARD ANALYTICAL PROTOCOL FOR ...

    EPA Pesticide Factsheets

    There is a growing concern with the potential for terrorist use of chemical weapons to cause civilian harm. In the event of an actual or suspected outdoor release of chemically hazardous material in a large area, the extent of contamination must be determined. This requires a system with the ability to prepare and quickly analyze a large number of contaminated samples for the traditional chemical agents, as well as numerous toxic industrial chemicals. Liquid samples (both aqueous and organic), solid samples (e.g., soil), vapor samples (e.g., air) and mixed state samples, all ranging from household items to deceased animals, may require some level of analyses. To meet this challenge, the U.S. Environmental Protection Agency (U.S. EPA) National Homeland Security Research Center, in collaboration with experts from across U.S. EPA and other Federal Agencies, initiated an effort to identify analytical methods for the chemical and biological agents that could be used to respond to a terrorist attack or a homeland security incident. U.S. EPA began development of standard analytical protocols (SAPs) for laboratory identification and measurement of target agents in case of a contamination threat. These methods will be used to help assist in the identification of existing contamination, the effectiveness of decontamination, as well as clearance for the affected population to reoccupy previously contaminated areas. One of the first SAPs developed was for the determin

  9. Method 1200: Analytical Protocol for Non-Typhoidal Salmonella in Drinking Water and Surface Water

    EPA Pesticide Factsheets

    Method 1200 is used for identification, confirmation and quantitation of non-typhoidal Salmonella in water samples, using selective and non-selective media followed by biochemical and serological confirmation.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jenkins, T.F.; Thorne, P.G.; Myers, K.F.

    Salting-out solvent extraction (SOE) was compared with cartridge and membrane solid-phase extraction (SPE) for preconcentration of nitroaromatics, nitramines, and aminonitroaromatics prior to determination by reversed-phase high-performance liquid chromatography. The solid phases used were manufacturer-cleaned materials, Porapak RDX for the cartridge method and Empore SDB-RPS for the membrane method. Thirty-three groundwater samples from the Naval Surface Warfare Center, Crane, Indiana, were analyzed using the direct analysis protocol specified in SW846 Method 8330, and the results were compared with analyses conducted after preconcentration using SOE with acetonitrile, cartridge-based SPE, and membrane-based SPE. For high-concentration samples, analytical results from the three preconcentration techniquesmore » were compared with results from the direct analysis protocol; good recovery of all target analytes was achieved by all three pre-concentration methods. For low-concentration samples, results from the two SPE methods were correlated with results from the SOE method; very similar data was obtained by the SOE and SPE methods, even at concentrations well below 1 microgram/L.« less

  11. Current Protocols in Pharmacology

    PubMed Central

    2016-01-01

    Determination of drug or drug metabolite concentrations in biological samples, particularly in serum or plasma, is fundamental to describing the relationships between administered dose, route of administration, and time after dose to the drug concentrations achieved and to the observed effects of the drug. A well-characterized, accurate analytical method is needed, but it must also be established that the analyte concentration in the sample at the time of analysis is the same as the concentration at sample acquisition. Drugs and metabolites may be susceptible to degradation in samples due to metabolism or to physical and chemical processes, resulting in a lower measured concentration than was in the original sample. Careful examination of analyte stability during processing and storage and adjustment of procedures and conditions to maximize that stability are a critical part of method validation for the analysis, and can ensure the accuracy of the measured concentrations. PMID:27960029

  12. Analytical methods for the determination of personal care products in human samples: an overview.

    PubMed

    Jiménez-Díaz, I; Zafra-Gómez, A; Ballesteros, O; Navalón, A

    2014-11-01

    Personal care products (PCPs) are organic chemicals widely used in everyday human life. Nowadays, preservatives, UV-filters, antimicrobials and musk fragrances are widely used PCPs. Different studies have shown that some of these compounds can cause adverse health effects, such as genotoxicity, which could even lead to mutagenic or carcinogenic effects, or estrogenicity because of their endocrine disruption activity. Due to the absence of official monitoring protocols, there is an increasing demand of analytical methods that allow the determination of those compounds in human samples in order to obtain more information regarding their behavior and fate in the human body. The complexity of the biological matrices and the low concentration levels of these compounds make necessary the use of advanced sample treatment procedures that afford both, sample clean-up, to remove potentially interfering matrix components, as well as the concentration of analytes. In the present work, a review of the more recent analytical methods published in the scientific literature for the determination of PCPs in human fluids and tissue samples, is presented. The work focused on sample preparation and the analytical techniques employed. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Sampled-data-based consensus and containment control of multiple harmonic oscillators: A motion-planning approach

    NASA Astrophysics Data System (ADS)

    Liu, Yongfang; Zhao, Yu; Chen, Guanrong

    2016-11-01

    This paper studies the distributed consensus and containment problems for a group of harmonic oscillators with a directed communication topology. First, for consensus without a leader, a class of distributed consensus protocols is designed by using motion planning and Pontryagin's principle. The proposed protocol only requires relative information measurements at the sampling instants, without requiring information exchange over the sampled interval. By using stability theory and the properties of stochastic matrices, it is proved that the distributed consensus problem can be solved in the motion planning framework. Second, for the case with multiple leaders, a class of distributed containment protocols is developed for followers such that their positions and velocities can ultimately converge to the convex hull formed by those of the leaders. Compared with the existing consensus algorithms, a remarkable advantage of the proposed sampled-data-based protocols is that the sampling periods, communication topologies and control gains are all decoupled and can be separately designed, which relaxes many restrictions in controllers design. Finally, some numerical examples are given to illustrate the effectiveness of the analytical results.

  14. Protocol for Tier 2 Evaluation of Vapor Intrusion at Corrective Action Sites

    DTIC Science & Technology

    2012-07-01

    622.92 600.12 437.08 433.44 411.1 Sulfur Hexafluoride (SF6) by NIOSH 6602 Modified Sulfur Hexafluoride 600 130 380 290 120 370 Notes: 1. VOC and SF6...6602 Modified Sulfur Hexafluoride 2400 2600 24 1500 260 14 18 1000 Notes: 1. VOC and SF6 samples were analyzed by Columbia Analytical Services, Inc. in...NIOSH 6602 Modified Sulfur Hexafluoride 3900 15 1800 1700 24 1600 Notes: 1. VOC and SF6 samples were analyzed by Columbia Analytical Services, Inc. in

  15. Laboratory and quality assurance protocols for the analysis of herbicides in ground water from the Management Systems Evaluation Area, Princeton, Minnesota

    USGS Publications Warehouse

    Larson, S.J.; Capel, P.D.; VanderLoop, A.G.

    1996-01-01

    Laboratory and quality assurance procedures for the analysis of ground-water samples for herbicides at the Management Systems Evaluation Area near Princeton, Minnesota are described. The target herbicides include atrazine, de-ethylatrazine, de-isopropylatrazine, metribuzin, alachlor, 2,6-diethylaniline, and metolachlor. The analytical techniques used are solid-phase extraction, and analysis by gas chromatography with mass-selective detection. Descriptions of cleaning procedures, preparation of standard solutions, isolation of analytes from water, sample transfer methods, instrumental analysis, and data analysis are included.

  16. Outgassing and dimensional changes of polymer matrix composites in space

    NASA Technical Reports Server (NTRS)

    Tennyson, R. C.; Matthews, R.

    1993-01-01

    A thermal-vacuum outgassing model and test protocol for predicting outgassing times and dimensional changes for polymer matrix composites is described. Experimental results derived from a 'control' sample are used to provide the basis for analytical predictions to compare with the outgassing response of Long Duration Exposure Facility (LDEF) flight samples.

  17. Evaluation of a reduced centrifugation time and higher centrifugal force on various general chemistry and immunochemistry analytes in plasma and serum.

    PubMed

    Møller, Mette F; Søndergaard, Tove R; Kristensen, Helle T; Münster, Anna-Marie B

    2017-09-01

    Background Centrifugation of blood samples is an essential preanalytical step in the clinical biochemistry laboratory. Centrifugation settings are often altered to optimize sample flow and turnaround time. Few studies have addressed the effect of altering centrifugation settings on analytical quality, and almost all studies have been done using collection tubes with gel separator. Methods In this study, we compared a centrifugation time of 5 min at 3000 ×  g to a standard protocol of 10 min at 2200 ×  g. Nine selected general chemistry and immunochemistry analytes and interference indices were studied in lithium heparin plasma tubes and serum tubes without gel separator. Results were evaluated using mean bias, difference plots and coefficient of variation, compared with maximum allowable bias and coefficient of variation used in laboratory routine quality control. Results For all analytes except lactate dehydrogenase, the results were within the predefined acceptance criteria, indicating that the analytical quality was not compromised. Lactate dehydrogenase showed higher values after centrifugation for 5 min at 3000 ×  g, mean bias was 6.3 ± 2.2% and the coefficient of variation was 5%. Conclusions We found that a centrifugation protocol of 5 min at 3000 ×  g can be used for the general chemistry and immunochemistry analytes studied, with the possible exception of lactate dehydrogenase, which requires further assessment.

  18. Incorporating Aptamers in the Multiple Analyte Profiling Assays (xMAP): Detection of C-Reactive Protein.

    PubMed

    Bernard, Elyse D; Nguyen, Kathy C; DeRosa, Maria C; Tayabali, Azam F; Aranda-Rodriguez, Rocio

    2017-01-01

    Aptamers are short oligonucleotide sequences used in detection systems because of their high affinity binding to a variety of macromolecules. With the introduction of aptamers over 25 years ago came the exploration of their use in many different applications as a substitute for antibodies. Aptamers have several advantages; they are easy to synthesize, can bind to analytes for which it is difficult to obtain antibodies, and in some cases bind better than antibodies. As such, aptamer applications have significantly expanded as an adjunct to a variety of different immunoassay designs. The Multiple-Analyte Profiling (xMAP) technology developed by Luminex Corporation commonly uses antibodies for the detection of analytes in small sample volumes through the use of fluorescently coded microbeads. This technology permits the simultaneous detection of multiple analytes in each sample tested and hence could be applied in many research fields. Although little work has been performed adapting this technology for use with apatmers, optimizing aptamer-based xMAP assays would dramatically increase the versatility of analyte detection. We report herein on the development of an xMAP bead-based aptamer/antibody sandwich assay for a biomarker of inflammation (C-reactive protein or CRP). Protocols for the coupling of aptamers to xMAP beads, validation of coupling, and for an aptamer/antibody sandwich-type assay for CRP are detailed. The optimized conditions, protocols and findings described in this research could serve as a starting point for the development of new aptamer-based xMAP assays.

  19. Elucidation of several neglected reactions in the GC-MS identification of sialic acids as heptafluorobutyrates calls for an urgent reassessment of previous claims.

    PubMed

    Rota, Paola; Anastasia, Luigi; Allevi, Pietro

    2015-05-07

    The current analytical protocol used for the GC-MS determination of free or 1,7-lactonized natural sialic acids (Sias), as heptafluorobutyrates, overlooks several transformations. Using authentic reference standards and by combining GC-MS and NMR analyses, flaws in the analytical protocol were pinpointed and elucidated, thus establishing the scope and limitations of the method. It was demonstrated that (a) Sias 1,7-lactones, even if present in biological samples, decompose under the acidic hydrolysis conditions used for their release; (b) Sias 1,7-lactones are unpredicted artifacts, accidentally generated from their parent acids; (c) the N-acetyl group is quantitatively exchanged with that of the derivatizing perfluorinated anhydride; (d) the partial or complete failure of the Sias esterification-step with diazomethane leads to the incorrect quantification and structure attribution of all free Sias. While these findings prompt an urgent correction and improvement of the current analytical protocol, they could be instrumental for a critical revision of many incorrect claims reported in the literature.

  20. Quantification of trace elements and speciation of iron in atmospheric particulate matter

    NASA Astrophysics Data System (ADS)

    Upadhyay, Nabin

    Trace metal species play important roles in atmospheric redox processes and in the generation of oxidants in cloud systems. The chemical impact of these elements on atmospheric and cloud chemistry is dependent on their occurrence, solubility and speciation. First, analytical protocols have been developed to determine trace elements in particulate matter samples collected for carbonaceous analysis. The validated novel protocols were applied to the determination of trace elements in particulate samples collected in the remote marine atmosphere and urban areas in Arizona to study air pollution issues. The second part of this work investigates on solubility and speciation in environmental samples. A detailed study on the impact of the nature and strength of buffer solutions on solubility and speciation of iron lead to a robust protocol, allowing for comparative measurements in matrices representative of cloud water conditions. Application of this protocol to samples from different environments showed low iron solubility (less than 1%) in dust-impacted events and higher solubility (5%) in anthropogenically impacted urban samples. In most cases, Fe(II) was the dominant oxidation state in the soluble fraction of iron. The analytical protocol was then applied to investigate iron processing by fogs. Field observations showed that only a small fraction (1%) of iron was scavenged by fog droplets for which each of the soluble and insoluble fraction were similar. A coarse time resolution limited detailed insights into redox cycling within fog system. Overall results suggested that the major iron species in the droplets was Fe(1I) (80% of soluble iron). Finally, the occurrence and sources of emerging organic pollutants in the urban atmosphere were investigated. Synthetic musk species are ubiquitous in the urban environment (less than 5 ng m-3) and investigations at wastewater treatment plants showed that wastewater aeration basins emit a substantial amount of these species to the atmosphere.

  1. A Systematic Evaluation of Blood Serum and Plasma Pre-Analytics for Metabolomics Cohort Studies

    PubMed Central

    Jobard, Elodie; Trédan, Olivier; Postoly, Déborah; André, Fabrice; Martin, Anne-Laure; Elena-Herrmann, Bénédicte; Boyault, Sandrine

    2016-01-01

    The recent thriving development of biobanks and associated high-throughput phenotyping studies requires the elaboration of large-scale approaches for monitoring biological sample quality and compliance with standard protocols. We present a metabolomic investigation of human blood samples that delineates pitfalls and guidelines for the collection, storage and handling procedures for serum and plasma. A series of eight pre-processing technical parameters is systematically investigated along variable ranges commonly encountered across clinical studies. While metabolic fingerprints, as assessed by nuclear magnetic resonance, are not significantly affected by altered centrifugation parameters or delays between sample pre-processing (blood centrifugation) and storage, our metabolomic investigation highlights that both the delay and storage temperature between blood draw and centrifugation are the primary parameters impacting serum and plasma metabolic profiles. Storing the blood drawn at 4 °C is shown to be a reliable routine to confine variability associated with idle time prior to sample pre-processing. Based on their fine sensitivity to pre-analytical parameters and protocol variations, metabolic fingerprints could be exploited as valuable ways to determine compliance with standard procedures and quality assessment of blood samples within large multi-omic clinical and translational cohort studies. PMID:27929400

  2. Base Realignment and Closure Environmental Evaluation (BRAC EE) Fort Devens, Massachusetts

    DTIC Science & Technology

    1995-09-01

    Not Sampled ......... 6 2.3.2 Transformer Sites Sampled ........................ 7 2.4 Soil Sampling Protocol and Analytical Program ...Evaluation (AREE) 66. The study included evaluating the current PCB Transformer Management Program administered by the Fort Devens Environmental Management...Office (EMO), the Fort Devens Spill Contingency Plan, and the ongoing transformer inspection program . Personnel in both the Fort Devens EMO and the Fort

  3. A Field-Based Cleaning Protocol for Sampling Devices Used in Life-Detection Studies

    NASA Astrophysics Data System (ADS)

    Eigenbrode, Jennifer; Benning, Liane G.; Maule, Jake; Wainwright, Norm; Steele, Andrew; Amundsen, Hans E. F.

    2009-06-01

    Analytical approaches to extant and extinct life detection involve molecular detection often at trace levels. Thus, removal of biological materials and other organic molecules from the surfaces of devices used for sampling is essential for ascertaining meaningful results. Organic decontamination to levels consistent with null values on life-detection instruments is particularly challenging at remote field locations where Mars analog field investigations are carried out. Here, we present a seven-step, multi-reagent decontamination method that can be applied to sampling devices while in the field. In situ lipopolysaccharide detection via low-level endotoxin assays and molecular detection via gas chromatography-mass spectrometry were used to test the effectiveness of the decontamination protocol for sampling of glacial ice with a coring device and for sampling of sediments with a rover scoop during deployment at Arctic Mars-analog sites in Svalbard, Norway. Our results indicate that the protocols and detection technique sufficiently remove and detect low levels of molecular constituents necessary for life-detection tests.

  4. A field-based cleaning protocol for sampling devices used in life-detection studies.

    PubMed

    Eigenbrode, Jennifer; Benning, Liane G; Maule, Jake; Wainwright, Norm; Steele, Andrew; Amundsen, Hans E F

    2009-06-01

    Analytical approaches to extant and extinct life detection involve molecular detection often at trace levels. Thus, removal of biological materials and other organic molecules from the surfaces of devices used for sampling is essential for ascertaining meaningful results. Organic decontamination to levels consistent with null values on life-detection instruments is particularly challenging at remote field locations where Mars analog field investigations are carried out. Here, we present a seven-step, multi-reagent decontamination method that can be applied to sampling devices while in the field. In situ lipopolysaccharide detection via low-level endotoxin assays and molecular detection via gas chromatography-mass spectrometry were used to test the effectiveness of the decontamination protocol for sampling of glacial ice with a coring device and for sampling of sediments with a rover scoop during deployment at Arctic Mars-analog sites in Svalbard, Norway. Our results indicate that the protocols and detection technique sufficiently remove and detect low levels of molecular constituents necessary for life-detection tests.

  5. Mars Sample Handling Protocol Workshop Series: Workshop 4

    NASA Technical Reports Server (NTRS)

    Race Margaret S. (Editor); DeVincenzi, Donald L. (Editor); Rummel, John D. (Editor); Acevedo, Sara E. (Editor)

    2001-01-01

    In preparation for missions to Mars that will involve the return of samples to Earth, it will be necessary to prepare for the receiving, handling, testing, distributing, and archiving of martian materials here on Earth. Previous groups and committees have studied selected aspects of sample return activities, but specific detailed protocols for the handling and testing of returned samples must still be developed. To further refine the requirements for sample hazard testing and to develop the criteria for subsequent release of sample materials from quarantine, the NASA Planetary Protection Officer convened a series of workshops in 2000-2001. The overall objective of the Workshop Series was to produce a Draft Protocol by which returned martian sample materials can be assessed for biological hazards and examined for evidence of life (extant or extinct) while safeguarding the purity of the samples from possible terrestrial contamination. This report also provides a record of the proceedings of Workshop 4, the final Workshop of the Series, which was held in Arlington, Virginia, June 5-7, 2001. During Workshop 4, the sub-groups were provided with a draft of the protocol compiled in May 2001 from the work done at prior Workshops in the Series. Then eight sub-groups were formed to discuss the following assigned topics: Review and Assess the Draft Protocol for Physical/Chemical Testing Review and Assess the Draft Protocol for Life Detection Testing Review and Assess the Draft Protocol for Biohazard Testing Environmental and Health/Monitoring and Safety Issues Requirements of the Draft Protocol for Facilities and Equipment Contingency Planning for Different Outcomes of the Draft Protocol Personnel Management Considerations in Implementation of the Draft Protocol Draft Protocol Implementation Process and Update Concepts This report provides the first complete presentation of the Draft Protocol for Mars Sample Handling to meet planetary protection needs. This Draft Protocol, which was compiled from deliberations and recommendations from earlier Workshops in the Series, represents a consensus that emerged from the discussions of all the sub-groups assembled over the course of the five Workshops of the Series. These discussions converged on a conceptual approach to sample handling, as well as on specific analytical requirements. Discussions also identified important issues requiring attention, as well as research and development needed for protocol implementation.

  6. Automation of serum (1→3)-beta-D-glucan testing allows reliable and rapid discrimination of patients with and without candidemia.

    PubMed

    Prüller, Florian; Wagner, Jasmin; Raggam, Reinhard B; Hoenigl, Martin; Kessler, Harald H; Truschnig-Wilders, Martie; Krause, Robert

    2014-07-01

    Testing for (1→3)-beta-D-glucan (BDG) is used for detection of invasive fungal infection. However, current assays lack automation and the ability to conduct rapid single-sample testing. The Fungitell assay was adopted for automation and evaluated using clinical samples from patients with culture-proven candidemia and from culture-negative controls in duplicate. A comparison with the standard assay protocol was made in order to establish analytical specifications. With the automated protocol, the analytical measuring range was 8-2500 pg/ml of BDG, and precision testing resulted in coefficients of variation that ranged from 3.0% to 5.5%. Samples from 15 patients with culture-proven candidemia and 94 culture-negative samples were evaluated. All culture-proven samples showed BDG values >80 pg/ml (mean 1247 pg/ml; range, 116-2990 pg/ml), which were considered positive. Of the 94 culture-negative samples, 92 had BDG values <60 pg/ml (mean, 28 pg/ml), which were considered to be negative, and 2 samples were false-positive (≥80 pg/ml; up to 124 pg/ml). Results could be obtained within 45 min and showed excellent agreement with results obtained with the standard assay protocol. The automated Fungitell assay proved to be reliable and rapid for diagnosis of candidemia. It was demonstrated to be feasible and cost efficient for both single-sample and large-scale testing of serum BDG. Its 1-h time-to-result will allow better support for clinicians in the management of antifungal therapy. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Isotope Inversion Experiment evaluating the suitability of calibration in surrogate matrix for quantification via LC-MS/MS-Exemplary application for a steroid multi-method.

    PubMed

    Suhr, Anna Catharina; Vogeser, Michael; Grimm, Stefanie H

    2016-05-30

    For quotable quantitative analysis of endogenous analytes in complex biological samples by isotope dilution LC-MS/MS, the creation of appropriate calibrators is a challenge, since analyte-free authentic material is in general not available. Thus, surrogate matrices are often used to prepare calibrators and controls. However, currently employed validation protocols do not include specific experiments to verify the suitability of a surrogate matrix calibration for quantification of authentic matrix samples. The aim of the study was the development of a novel validation experiment to test whether surrogate matrix based calibrators enable correct quantification of authentic matrix samples. The key element of the novel validation experiment is the inversion of nonlabelled analytes and their stable isotope labelled (SIL) counterparts in respect to their functions, i.e. SIL compound is the analyte and nonlabelled substance is employed as internal standard. As a consequence, both surrogate and authentic matrix are analyte-free regarding SIL analytes, which allows a comparison of both matrices. We called this approach Isotope Inversion Experiment. As figure of merit we defined the accuracy of inverse quality controls in authentic matrix quantified by means of a surrogate matrix calibration curve. As a proof-of-concept application a LC-MS/MS assay addressing six corticosteroids (cortisol, cortisone, corticosterone, 11-deoxycortisol, 11-deoxycorticosterone, and 17-OH-progesterone) was chosen. The integration of the Isotope Inversion Experiment in the validation protocol for the steroid assay was successfully realized. The accuracy results of the inverse quality controls were all in all very satisfying. As a consequence the suitability of a surrogate matrix calibration for quantification of the targeted steroids in human serum as authentic matrix could be successfully demonstrated. The Isotope Inversion Experiment fills a gap in the validation process for LC-MS/MS assays quantifying endogenous analytes. We consider it a valuable and convenient tool to evaluate the correct quantification of authentic matrix samples based on a calibration curve in surrogate matrix. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. 40 CFR 61.356 - Recordkeeping requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... test protocol and the means by which sampling variability and analytical variability were accounted for... also establish the design minimum and average temperature in the combustion zone and the combustion... the design minimum and average temperatures across the catalyst bed inlet and outlet. (C) For a boiler...

  9. ANALYTICAL METHODS FOR FUEL OXYGENATES

    EPA Science Inventory

    MTBE (and potentially any other oxygenate) may be present at any petroleum UST site, whether the release is new or old, virtually anywhere in the United States. Consequently, it is prudent to analyze samples for the entire suite of oxygenates as identified in this protocol (i.e....

  10. Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples

    PubMed Central

    Chen, Ping-Hung; Chen, Shun-Niang; Tseng, Sheng-Hao; Deng, Ming-Jay; Lin, Yang-Wei; Sun, Yuh-Chang

    2016-01-01

    This paper describes a fabrication protocol for a dipole-assisted solid phase extraction (SPE) microchip available for trace metal analysis in water samples. A brief overview of the evolution of chip-based SPE techniques is provided. This is followed by an introduction to specific polymeric materials and their role in SPE. To develop an innovative dipole-assisted SPE technique, a chlorine (Cl)-containing SPE functionality was implanted into a poly(methyl methacrylate) (PMMA) microchip. Herein, diverse analytical techniques including contact angle analysis, Raman spectroscopic analysis, and laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) analysis were employed to validate the utility of the implantation protocol of the C-Cl moieties on the PMMA. The analytical results of the X-ray absorption near-edge structure (XANES) analysis also demonstrated the feasibility of the Cl-containing PMMA used as an extraction medium by virtue of the dipole-ion interactions between the highly electronegative C-Cl moieties and the positively charged metal ions. PMID:27584954

  11. Evolving Pb isotope signatures of London airborne particulate matter (PM 10)-constraints from on-filter and solution-mode MC-ICP-MS.

    PubMed

    Noble, Stephen R; Horstwood, Matthew S A; Davy, Pamela; Pashley, Vanessa; Spiro, Baruch; Smith, Steve

    2008-07-01

    Pb isotope compositions of biologically significant PM(10) atmospheric particulates from a busy roadside location in London UK were measured using solution- and laser ablation-mode MC-ICP-MS. The solution-mode data for PM(10) sampled between 1998-2001 document a dramatic shift to increasingly radiogenic compositions as leaded petrol was phased out. LA-MC-ICP-MS isotope analysis, piloted on a subset of the available samples, is shown to be a potential reconnaissance analytical technique. PM(10) particles trapped on quartz filters were liberated from the filter surface, without ablating the filter substrate, using a 266 nm UV laser and a dynamic, large diameter, low-fluence ablation protocol. The Pb isotope evolution noted in the London data set obtained by both analytical protocols is similar to that observed elsewhere in Western Europe following leaded petrol elimination. The data therefore provide important baseline isotope composition information useful for continued UK atmospheric monitoring through the early 21(st) century.

  12. Miniaturized Temperature-Controlled Planar Chromatography (Micro-TLC) as a Versatile Technique for Fast Screening of Micropollutants and Biomarkers Derived from Surface Water Ecosystems and During Technological Processes of Wastewater Treatment.

    PubMed

    Ślączka-Wilk, Magdalena M; Włodarczyk, Elżbieta; Kaleniecka, Aleksandra; Zarzycki, Paweł K

    2017-07-01

    There is increasing interest in the development of simple analytical systems enabling the fast screening of target components in complex samples. A number of newly invented protocols are based on quasi separation techniques involving microfluidic paper-based analytical devices and/or micro total analysis systems. Under such conditions, the quantification of target components can be performed mainly due to selective detection. The main goal of this paper is to demonstrate that miniaturized planar chromatography has the capability to work as an efficient separation and quantification tool for the analysis of multiple targets within complex environmental samples isolated and concentrated using an optimized SPE method. In particular, we analyzed various samples collected from surface water ecosystems (lakes, rivers, and the Baltic Sea of Middle Pomerania in the northern part of Poland) in different seasons, as well as samples collected during key wastewater technological processes (originating from the "Jamno" wastewater treatment plant in Koszalin, Poland). We documented that the multiple detection of chromatographic spots on RP-18W microplates-under visible light, fluorescence, and fluorescence quenching conditions, and using the visualization reagent phosphomolybdic acid-enables fast and robust sample classification. The presented data reveal that the proposed micro-TLC system is useful, inexpensive, and can be considered as a complementary method for the fast control of treated sewage water discharged by a municipal wastewater treatment plant, particularly for the detection of low-molecular mass micropollutants with polarity ranging from estetrol to progesterone, as well as chlorophyll-related dyes. Due to the low consumption of mobile phases composed of water-alcohol binary mixtures (less than 1 mL/run for the simultaneous separation of up to nine samples), this method can be considered an environmentally friendly and green chemistry analytical tool. The described analytical protocol can be complementary to those involving classical column chromatography (HPLC) or various planar microfluidic devices.

  13. Pilot studies for the North American Soil Geochemical Landscapes Project - Site selection, sampling protocols, analytical methods, and quality control protocols

    USGS Publications Warehouse

    Smith, D.B.; Woodruff, L.G.; O'Leary, R. M.; Cannon, W.F.; Garrett, R.G.; Kilburn, J.E.; Goldhaber, M.B.

    2009-01-01

    In 2004, the US Geological Survey (USGS) and the Geological Survey of Canada sampled and chemically analyzed soils along two transects across Canada and the USA in preparation for a planned soil geochemical survey of North America. This effort was a pilot study to test and refine sampling protocols, analytical methods, quality control protocols, and field logistics for the continental survey. A total of 220 sample sites were selected at approximately 40-km intervals along the two transects. The ideal sampling protocol at each site called for a sample from a depth of 0-5 cm and a composite of each of the O, A, and C horizons. The <2-mm fraction of each sample was analyzed for Al, Ca, Fe, K, Mg, Na, S, Ti, Ag, As, Ba, Be, Bi, Cd, Ce, Co, Cr, Cs, Cu, Ga, In, La, Li, Mn, Mo, Nb, Ni, P, Pb, Rb, Sb, Sc, Sn, Sr, Te, Th, Tl, U, V, W, Y, and Zn by inductively coupled plasma-mass spectrometry and inductively coupled plasma-atomic emission spectrometry following a near-total digestion in a mixture of HCl, HNO3, HClO4, and HF. Separate methods were used for Hg, Se, total C, and carbonate-C on this same size fraction. Only Ag, In, and Te had a large percentage of concentrations below the detection limit. Quality control (QC) of the analyses was monitored at three levels: the laboratory performing the analysis, the USGS QC officer, and the principal investigator for the study. This level of review resulted in an average of one QC sample for every 20 field samples, which proved to be minimally adequate for such a large-scale survey. Additional QC samples should be added to monitor within-batch quality to the extent that no more than 10 samples are analyzed between a QC sample. Only Cr (77%), Y (82%), and Sb (80%) fell outside the acceptable limits of accuracy (% recovery between 85 and 115%) because of likely residence in mineral phases resistant to the acid digestion. A separate sample of 0-5-cm material was collected at each site for determination of organic compounds. A subset of 73 of these samples was analyzed for a suite of 19 organochlorine pesticides by gas chromatography. Only three of these samples had detectable pesticide concentrations. A separate sample of A-horizon soil was collected for microbial characterization by phospholipid fatty acid analysis (PLFA), soil enzyme assays, and determination of selected human and agricultural pathogens. Collection, preservation and analysis of samples for both organic compounds and microbial characterization add a great degree of complication to the sampling and preservation protocols and a significant increase to the cost for a continental-scale survey. Both these issues must be considered carefully prior to adopting these parameters as part of the soil geochemical survey of North America.

  14. Successful attack on permutation-parity-machine-based neural cryptography.

    PubMed

    Seoane, Luís F; Ruttor, Andreas

    2012-02-01

    An algorithm is presented which implements a probabilistic attack on the key-exchange protocol based on permutation parity machines. Instead of imitating the synchronization of the communicating partners, the strategy consists of a Monte Carlo method to sample the space of possible weights during inner rounds and an analytic approach to convey the extracted information from one outer round to the next one. The results show that the protocol under attack fails to synchronize faster than an eavesdropper using this algorithm.

  15. National survey on the pre-analytical variability in a representative cohort of Italian laboratories.

    PubMed

    Lippi, Giuseppe; Montagnana, Martina; Giavarina, Davide

    2006-01-01

    Owing to remarkable advances in automation, laboratory technology and informatics, the pre-analytical phase has become the major source of variability in laboratory testing. The present survey investigated the development of several pre-analytical processes within a representative cohort of Italian clinical laboratories. A seven-point questionnaire was designed to investigate the following issues: 1a) the mean outpatient waiting time before check-in and 1b) the mean time from check-in to sample collection; 2) the mean time from sample collection to analysis; 3) the type of specimen collected for clinical chemistry testing; 4) the degree of pre-analytical automation; 5a) the number of samples shipped to other laboratories and 5b) the availability of standardised protocols for transportation; 6) the conditions for specimen storage; and 7) the availability and type of guidelines for management of unsuitable specimens. The questionnaire was administered to 150 laboratory specialists attending the SIMEL (Italian Society of Laboratory Medicine) National Meeting in June 2006. 107 questionnaires (71.3%) were returned. Data analysis revealed a high degree of variability among laboratories for the time required for check-in, outpatient sampling, sample transportation to the referral laboratory and analysis upon the arrival. Only 31% of laboratories have automated some pre-analytical steps. Of the 87% of laboratories that ship specimens to other facilities without sample preparation, 19% have no standardised protocol for transportation. For conventional clinical chemistry testing, 74% of the laboratories use serum evacuated tubes (59% with and 15% without serum separator), whereas the remaining 26% use lithium-heparin evacuated tubes (11% with and 15% without plasma separator). The storage period and conditions for rerun/retest vary widely. Only 63% of laboratories have a codified procedure for the management of unsuitable specimens, which are recognised by visual inspection (69%) or automatic detection (29%). Only 56% of the laboratories have standardised procedures for the management of unsuitable specimens, which vary widely on a local basis. The survey highlights broad heterogeneity in several pre-analytical processes among Italian laboratories. The lack of reliable guidelines encompassing evidence-based practice is a major problem for the standardisation of this crucial part of the testing process and represents a major challenge for laboratory medicine in the 2000s.

  16. Soil sampling and analytical strategies for mapping fallout in nuclear emergencies based on the Fukushima Dai-ichi Nuclear Power Plant accident.

    PubMed

    Onda, Yuichi; Kato, Hiroaki; Hoshi, Masaharu; Takahashi, Yoshio; Nguyen, Minh-Long

    2015-01-01

    The Fukushima Dai-ichi Nuclear Power Plant (FDNPP) accident resulted in extensive radioactive contamination of the environment via deposited radionuclides such as radiocesium and (131)I. Evaluating the extent and level of environmental contamination is critical to protecting citizens in affected areas and to planning decontamination efforts. However, a standardized soil sampling protocol is needed in such emergencies to facilitate the collection of large, tractable samples for measuring gamma-emitting radionuclides. In this study, we developed an emergency soil sampling protocol based on preliminary sampling from the FDNPP accident-affected area. We also present the results of a preliminary experiment aimed to evaluate the influence of various procedures (e.g., mixing, number of samples) on measured radioactivity. Results show that sample mixing strongly affects measured radioactivity in soil samples. Furthermore, for homogenization, shaking the plastic sample container at least 150 times or disaggregating soil by hand-rolling in a disposable plastic bag is required. Finally, we determined that five soil samples within a 3 m × 3-m area are the minimum number required for reducing measurement uncertainty in the emergency soil sampling protocol proposed here. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Identification and quantitative determination of diphenylarsenic compounds in abandoned toxic smoke canisters.

    PubMed

    Hanaoka, Shigeyuki; Nomura, Koji; Kudo, Shinichi

    2005-09-02

    Knowledge of the exact nature of the constituents of abandoned chemical weapons (ACW) is a prerequisite for their orderly destruction. Here we report the development of analytical procedures to identify diphenylchloroarsine (DA/Clark I), diphenylcyanoarsine (DC/Clark II) and related substances employed in one of the munitions known as "Red canister". Both DA and DC are relatively unstable under conventional analytical procedures without thiol derivatization. Unfortunately however, thiol drivatization affords the same volatile organo-arsenic derivative from several different diphenylarsenic compounds, making it impossible to identify and quantify the original compounds. Further, diminishing the analytical interference caused by the celluloid powder used as a stacking material in the weapons, is also essential for accurate analysis. In this study, extraction and instrumental conditions have been evaluated and an optimal protocol was determined. The analysis of Red canister samples following this protocol showed that most of the DA and DC associated with pumice had degraded to bis(diphenylarsine)oxide (BDPAO), while those associated with celluloid were dominantly degraded to diphenylarsinic acid (DPAA).

  18. [Sampling, storage and transport of biological materials collected from living and deceased subjects for determination of concentration levels of ethyl alcohol and similarly acting substances. A proposal of updating the blood and urine sampling protocol].

    PubMed

    Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew

    2007-01-01

    The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.

  19. Multipinhole SPECT helical scan parameters and imaging volume

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yao, Rutao, E-mail: rutaoyao@buffalo.edu; Deng, Xiao; Wei, Qingyang

    Purpose: The authors developed SPECT imaging capability on an animal PET scanner using a multiple-pinhole collimator and step-and-shoot helical data acquisition protocols. The objective of this work was to determine the preferred helical scan parameters, i.e., the angular and axial step sizes, and the imaging volume, that provide optimal imaging performance. Methods: The authors studied nine helical scan protocols formed by permuting three rotational and three axial step sizes. These step sizes were chosen around the reference values analytically calculated from the estimated spatial resolution of the SPECT system and the Nyquist sampling theorem. The nine helical protocols were evaluatedmore » by two figures-of-merit: the sampling completeness percentage (SCP) and the root-mean-square (RMS) resolution. SCP was an analytically calculated numerical index based on projection sampling. RMS resolution was derived from the reconstructed images of a sphere-grid phantom. Results: The RMS resolution results show that (1) the start and end pinhole planes of the helical scheme determine the axial extent of the effective field of view (EFOV), and (2) the diameter of the transverse EFOV is adequately calculated from the geometry of the pinhole opening, since the peripheral region beyond EFOV would introduce projection multiplexing and consequent effects. The RMS resolution results of the nine helical scan schemes show optimal resolution is achieved when the axial step size is the half, and the angular step size is about twice the corresponding values derived from the Nyquist theorem. The SCP results agree in general with that of RMS resolution but are less critical in assessing the effects of helical parameters and EFOV. Conclusions: The authors quantitatively validated the effective FOV of multiple pinhole helical scan protocols and proposed a simple method to calculate optimal helical scan parameters.« less

  20. A 'smart' tube holder enables real-time sample monitoring in a standard lab centrifuge.

    PubMed

    Hoang, Tony; Moskwa, Nicholas; Halvorsen, Ken

    2018-01-01

    The centrifuge is among the oldest and most widely used pieces of laboratory equipment, with significant applications that include clinical diagnostics and biomedical research. A major limitation of laboratory centrifuges is their "black box" nature, limiting sample observation to before and after centrifugation. Thus, optimized protocols require significant trial and error, while unoptimized protocols waste time by centrifuging longer than necessary or material due to incomplete sedimentation. Here, we developed an instrumented centrifuge tube receptacle compatible with several commercial benchtop centrifuges that can provide real-time sample analysis during centrifugation. We demonstrated the system by monitoring cell separations during centrifugation for different spin speeds, concentrations, buffers, cell types, and temperatures. We show that the collected data are valuable for analytical purposes (e.g. quality control), or as feedback to the user or the instrument. For the latter, we verified an adaptation where complete sedimentation turned off the centrifuge and notified the user by a text message. Our system adds new functionality to existing laboratory centrifuges, saving users time and providing useful feedback. This add-on potentially enables new analytical applications for an instrument that has remained largely unchanged for decades.

  1. A ‘smart’ tube holder enables real-time sample monitoring in a standard lab centrifuge

    PubMed Central

    Hoang, Tony; Moskwa, Nicholas

    2018-01-01

    The centrifuge is among the oldest and most widely used pieces of laboratory equipment, with significant applications that include clinical diagnostics and biomedical research. A major limitation of laboratory centrifuges is their “black box” nature, limiting sample observation to before and after centrifugation. Thus, optimized protocols require significant trial and error, while unoptimized protocols waste time by centrifuging longer than necessary or material due to incomplete sedimentation. Here, we developed an instrumented centrifuge tube receptacle compatible with several commercial benchtop centrifuges that can provide real-time sample analysis during centrifugation. We demonstrated the system by monitoring cell separations during centrifugation for different spin speeds, concentrations, buffers, cell types, and temperatures. We show that the collected data are valuable for analytical purposes (e.g. quality control), or as feedback to the user or the instrument. For the latter, we verified an adaptation where complete sedimentation turned off the centrifuge and notified the user by a text message. Our system adds new functionality to existing laboratory centrifuges, saving users time and providing useful feedback. This add-on potentially enables new analytical applications for an instrument that has remained largely unchanged for decades. PMID:29659624

  2. Temperature-controlled micro-TLC: a versatile green chemistry and fast analytical tool for separation and preliminary screening of steroids fraction from biological and environmental samples.

    PubMed

    Zarzycki, Paweł K; Slączka, Magdalena M; Zarzycka, Magdalena B; Bartoszuk, Małgorzata A; Włodarczyk, Elżbieta; Baran, Michał J

    2011-11-01

    This paper is a continuation of our previous research focusing on development of micro-TLC methodology under temperature-controlled conditions. The main goal of present paper is to demonstrate separation and detection capability of micro-TLC technique involving simple analytical protocols without multi-steps sample pre-purification. One of the advantages of planar chromatography over its column counterpart is that each TLC run can be performed using non-previously used stationary phase. Therefore, it is possible to fractionate or separate complex samples characterized by heavy biological matrix loading. In present studies components of interest, mainly steroids, were isolated from biological samples like fish bile using single pre-treatment steps involving direct organic liquid extraction and/or deproteinization by freeze-drying method. Low-molecular mass compounds with polarity ranging from estetrol to progesterone derived from the environmental samples (lake water, untreated and treated sewage waters) were concentrated using optimized solid-phase extraction (SPE). Specific bands patterns for samples derived from surface water of the Middle Pomerania in northern part of Poland can be easily observed on obtained micro-TLC chromatograms. This approach can be useful as simple and non-expensive complementary method for fast control and screening of treated sewage water discharged by the municipal wastewater treatment plants. Moreover, our experimental results show the potential of micro-TLC as an efficient tool for retention measurements of a wide range of steroids under reversed-phase (RP) chromatographic conditions. These data can be used for further optimalization of SPE or HPLC systems working under RP conditions. Furthermore, we also demonstrated that micro-TLC based analytical approach can be applied as an effective method for the internal standard (IS) substance search. Generally, described methodology can be applied for fast fractionation or screening of the whole range of target substances as well as chemo-taxonomic studies and fingerprinting of complex mixtures, which are present in biological or environmental samples. Due to low consumption of eluent (usually 0.3-1mL/run) mainly composed of water-alcohol binary mixtures, this method can be considered as environmentally friendly and green chemistry focused analytical tool, supplementary to analytical protocols involving column chromatography or planar micro-fluidic devices. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. MC ICP-MS δ(34)S(VCDT) measurement of dissolved sulfate in environmental aqueous samples after matrix separation by means of an anion exchange membrane.

    PubMed

    Hanousek, Ondrej; Berger, Torsten W; Prohaska, Thomas

    2016-01-01

    Analysis of (34)S/(32)S of sulfate in rainwater and soil solutions can be seen as a powerful tool for the study of the sulfur cycle. Therefore, it is considered as a useful means, e.g., for amelioration and calibration of ecological or biogeochemical models. Due to several analytical limitations, mainly caused by low sulfate concentration in rainwater, complex matrix of soil solutions, limited sample volume, and high number of samples in ecosystem studies, a straightforward analytical protocol is required to provide accurate S isotopic data on a large set of diverse samples. Therefore, sulfate separation by anion exchange membrane was combined with precise isotopic measurement by multicollector inductively coupled plasma mass spectrometry (MC ICP-MS). The separation method proved to be able to remove quantitatively sulfate from matrix cations (Ca, K, Na, or Li) which is a precondition in order to avoid a matrix-induced analytical bias in the mass spectrometer. Moreover, sulfate exchange on the resin is capable of preconcentrating sulfate from low concentrated solutions (to factor 3 in our protocol). No significant sulfur isotope fractionation was observed during separation and preconcentration. MC ICP-MS operated at edge mass resolution has enabled the direct (34)S/(32)S analysis of sulfate eluted from the membrane, with an expanded uncertainty U (k = 2) down to 0.3 ‰ (a single measurement). The protocol was optimized and validated using different sulfate solutions and different matrix compositions. The optimized method was applied in a study on solute samples retrieved in a beech (Fagus sylvatica) forest in the Vienna Woods. Both rainwater (precipitation and tree throughfall) and soil solution δ (34)SVCDT ranged between 4 and 6 ‰, the ratio in soil solution being slightly lower. The lower ratio indicates that a considerable portion of the atmospherically deposited sulfate is cycled through the organic S pool before being released to the soil solution. Nearly the same trends and variations were observed in soil solution and rainwater δ (34)SVCDT values showing that sulfate adsorption/desorption are not important processes in the studied soil.

  4. Electroanalytical sensing of chromium(III) and (VI) utilising gold screen printed macro electrodes.

    PubMed

    Metters, Jonathan P; Kadara, Rashid O; Banks, Craig E

    2012-02-21

    We report the fabrication of gold screen printed macro electrodes which are electrochemically characterised and contrasted to polycrystalline gold macroelectrodes with their potential analytical application towards the sensing of chromium(III) and (VI) critically explored. It is found that while these gold screen printed macro electrodes have electrode kinetics typically one order of magnitude lower than polycrystalline gold macroelectrodes as is measured via a standard redox probe, in terms of analytical sensing, these gold screen printed macro electrodes mimic polycrystalline gold in terms of their analytical performance towards the sensing of chromium(III) and (VI), whilst boasting additional advantages over the macro electrode due to their disposable one-shot nature and the ease of mass production. An additional advantage of these gold screen printed macro electrodes compared to polycrystalline gold is the alleviation of the requirement to potential cycle the latter to form the required gold oxide which aids in the simplification of the analytical protocol. We demonstrate that gold screen printed macro electrodes allow the low micro-molar sensing of chromium(VI) in aqueous solutions over the range 10 to 1600 μM with a limit of detection (3σ) of 4.4 μM. The feasibility of the analytical protocol is also tested through chromium(VI) detection in environmental samples.

  5. Analytical validation of a reference laboratory ELISA for the detection of feline leukemia virus p27 antigen.

    PubMed

    Buch, Jesse S; Clark, Genevieve H; Cahill, Roberta; Thatcher, Brendon; Smith, Peter; Chandrashekar, Ramaswamy; Leutenegger, Christian M; O'Connor, Thomas P; Beall, Melissa J

    2017-09-01

    Feline leukemia virus (FeLV) is an oncogenic retrovirus of cats. Immunoassays for the p27 core protein of FeLV aid in the detection of FeLV infections. Commercial microtiter-plate ELISAs have rapid protocols and visual result interpretation, limiting their usefulness in high-throughput situations. The purpose of our study was to validate the PetChek FeLV 15 ELISA, which is designed for the reference laboratory, and incorporates sequential, orthogonal screening and confirmatory protocols. A cutoff for the screening assay was established with 100% accuracy using 309 feline samples (244 negative, 65 positive) defined by the combined results of FeLV PCR and an independent reference p27 antigen ELISA. Precision of the screening assay was measured using a panel of 3 samples (negative, low-positive, and high-positive). The intra-assay coefficient of variation (CV) was 3.9-7.9%; the inter-assay CV was 6.0-8.6%. For the confirmatory assay, the intra-assay CV was 3.0-4.7%, and the inter-assay CV was 7.4-9.7%. The analytical sensitivity for p27 antigen was 3.7 ng/mL for inactivated whole FeLV and 1.2 ng/mL for purified recombinant FeLV p27. Analytical specificity was demonstrated based on the absence of cross-reactivity to related retroviruses. No interference was observed for samples containing added bilirubin, hemoglobin, or lipids. Based on these results, the new high-throughput design of the PetChek FeLV 15 ELISA makes it suitable for use in reference laboratory settings and maintains overall analytical performance.

  6. Distributed event-triggered consensus strategy for multi-agent systems under limited resources

    NASA Astrophysics Data System (ADS)

    Noorbakhsh, S. Mohammad; Ghaisari, Jafar

    2016-01-01

    The paper proposes a distributed structure to address an event-triggered consensus problem for multi-agent systems which aims at concurrent reduction in inter-agent communication, control input actuation and energy consumption. Following the proposed approach, asymptotic convergence of all agents to consensus requires that each agent broadcasts its sampled-state to the neighbours and updates its control input only at its own triggering instants, unlike the existing related works. Obviously, it decreases the network bandwidth usage, sensor energy consumption, computation resources usage and actuator wears. As a result, it facilitates the implementation of the proposed consensus protocol in the real-world applications with limited resources. The stability of the closed-loop system under an event-based protocol is proved analytically. Some numerical results are presented which confirm the analytical discussion on the effectiveness of the proposed design.

  7. An Organic Decontamination Method for Sampling Devices used in Life-detection Studies

    NASA Technical Reports Server (NTRS)

    Eigenbrode, Jennifer; Maule, Jake; Wainwright, Norm; Steele, Andrew; Amundsen, Hans E.F.

    2008-01-01

    Organic decontamination of sampling and storage devices are crucial steps for life-detection, habitability, and ecological investigations of extremophiles living in the most inhospitable niches of Earth, Mars and elsewhere. However, one of the main stumbling blocks for Mars-analogue life-detection studies in terrestrial remote field-sites is the capability to clean instruments and sampling devices to organic levels consistent with null values. Here we present a new seven-step, multi-reagent cleaning and decontamination protocol that was adapted and tested on a glacial ice-coring device and on a rover-guided scoop used for sediment sampling both deployed multiple times during two field seasons of the Arctic Mars Analog Svalbard Expedition AMASE). The effectiveness of the protocols for both devices was tested by (1)in situ metabolic measurements via APT, (2)in situ lipopolysacchride (LPS) quantifications via low-level endotoxin assays, and(3) laboratory-based molecular detection via gas chromatography-mass spectrometry. Our results show that the combination and step-wise application of disinfectants with oxidative and solvation properties for sterilization are effective at removing cellular remnants and other organic traces to levels necessary for molecular organic- and life-detection studies. The validation of this seven-step protocol - specifically for ice sampling - allows us to proceed with confidence in kmskia4 analogue investigations of icy environments. However, results from a rover scoop test showed that this protocol is also suitable for null-level decontamination of sample acquisition devices. Thus, this protocol may be applicable to a variety of sampling devices and analytical instrumentation used for future astrobiology missions to Enceladus, and Europa, as well as for sample-return missions.

  8. Experimental control in software reliability certification

    NASA Technical Reports Server (NTRS)

    Trammell, Carmen J.; Poore, Jesse H.

    1994-01-01

    There is growing interest in software 'certification', i.e., confirmation that software has performed satisfactorily under a defined certification protocol. Regulatory agencies, customers, and prospective reusers all want assurance that a defined product standard has been met. In other industries, products are typically certified under protocols in which random samples of the product are drawn, tests characteristic of operational use are applied, analytical or statistical inferences are made, and products meeting a standard are 'certified' as fit for use. A warranty statement is often issued upon satisfactory completion of a certification protocol. This paper outlines specific engineering practices that must be used to preserve the validity of the statistical certification testing protocol. The assumptions associated with a statistical experiment are given, and their implications for statistical testing of software are described.

  9. Comparison of PCR methods for the detection of genetic variants of carp edema virus.

    PubMed

    Adamek, Mikolaj; Matras, Marek; Jung-Schroers, Verena; Teitge, Felix; Heling, Max; Bergmann, Sven M; Reichert, Michal; Way, Keith; Stone, David M; Steinhagen, Dieter

    2017-09-20

    The infection of common carp and its ornamental variety, koi, with the carp edema virus (CEV) is often associated with the occurrence of a clinical disease called 'koi sleepy disease'. The disease may lead to high mortality in both koi and common carp populations. To prevent further spread of the infection and the disease, a reliable detection method for this virus is required. However, the high genetic variability of the CEV p4a gene used for PCR-based diagnostics could be a serious obstacle for successful and reliable detection of virus infection in field samples. By analysing 39 field samples from different geographical origins obtained from koi and farmed carp and from all 3 genogroups of CEV, using several recently available PCR protocols, we investigated which of the protocols would allow the detection of CEV from all known genogroups present in samples from Central European carp or koi populations. The comparison of 5 different PCR protocols showed that the PCR assays (both end-point and quantitative) developed in the Centre for Environment, Fisheries and Aquaculture Science exhibited the highest analytical inclusivity and diagnostic sensitivity. Currently, this makes them the most suitable protocols for detecting viruses from all known CEV genogroups.

  10. Implications of the field sampling procedure of the LUCAS Topsoil Survey for uncertainty in soil organic carbon concentrations.

    NASA Astrophysics Data System (ADS)

    Lark, R. M.; Rawlins, B. G.; Lark, T. A.

    2014-05-01

    The LUCAS Topsoil survey is a pan-European Union initiative in which soil data were collected according to standard protocols from 19 967 sites. Any inference about soil variables is subject to uncertainty due to different sources of variability in the data. In this study we examine the likely magnitude of uncertainty due to the field-sampling protocol. The published sampling protocol (LUCAS, 2009) describes a procedure to form a composite soil sample from aliquots collected to a depth of between approximately 15-20. A v-shaped hole to the target depth is cut with a spade, then a slice is cut from one of the exposed surfaces. This methodology gives rather less control of the sampling depth than protocols used in other soil and geochemical surveys, this may be a substantial source of variation in uncultivated soils with strong contrasts between an organic-rich A-horizon and an underlying B-horizon. We extracted all representative profile descriptions from soil series recorded in the memoir of the 1:250 000-scale map of Northern England (Soil Survey of England and Wales, 1984) where the base of the A-horizon is less than 20 cm below the surface. The Soil Associations in which these 14 series are significant members cover approximately 17% of the area of Northern England, and are expected to be the mineral soils with the largest organic content. Soil Organic Carbon content and bulk density were extracted for the A- and B-horizons, along with the thickness of the horizons. Recorded bulk density, or prediction by a pedotransfer function, were also recorded. For any proposed angle of the v-shaped hole, the proportions of A- and B-horizon in the resulting sample may be computed by trigonometry. From the bulk density and SOC concentration of the horizons, the SOC concentration of the sample can be computed. For each Soil Series we drew 1000 random samples from a trapezoidal distribution of angles, with uniform density over the range corresponding to depths 15-20 cm and zero density for angles corresponding to depths larger than 21 cm or less than 14 cm. We computed the corresponding variance of sample SOC contents. We found that the variance in SOC determinations attributable to variation in sample depth for these uncultivated soils was of the same order of magnitude as the estimate of the subsampling + analytical variance component (both on a log scale) that we previously computed for soils in the UK (Rawlins et al., 2009). It seems unnecessary to accept this source of uncertainty, given the effort undertaken to reduce the analytical variation which is no larger (and often smaller) than this variation due to the field protocol. If pan-European soil monitoring is to be based on the LUCAS Topsoil survey, as suggested by an initial report, uncertainty could be reduced if the sampling depth was specified to a unique depth, rather than the current depth range. LUCAS. 2009. Instructions for Surveyors. Technical reference document C-1: General implementation, Land Cover and Use, Water management, Soil, Transect, Photos. European Commission, Eurostat. Rawlins, B.G., Scheib, A.J., Lark, R.M. & Lister, T.R. 2009. Sampling and analytical plus subsampling variance components for five soil indicators observed at regional scale. European Journal of Soil Science 60, 740-747

  11. Saffron Samples of Different Origin: An NMR Study of Microwave-Assisted Extracts

    PubMed Central

    Sobolev, Anatoly P.; Carradori, Simone; Capitani, Donatella; Vista, Silvia; Trella, Agata; Marini, Federico; Mannina, Luisa

    2014-01-01

    An NMR analytical protocol is proposed to characterize saffron samples of different geographical origin (Greece, Spain, Hungary, Turkey and Italy). A microwave-assisted extraction procedure was developed to obtain a comparable recovery of metabolites with respect to the ISO specifications, reducing the solvent volume and the extraction time needed. Metabolite profiles of geographically different saffron extracts were compared showing significant differences in the content of some metabolites. PMID:28234327

  12. Next Generation Offline Approaches to Trace Gas-Phase Organic Compound Speciation: Sample Collection and Analysis

    NASA Astrophysics Data System (ADS)

    Sheu, R.; Marcotte, A.; Khare, P.; Ditto, J.; Charan, S.; Gentner, D. R.

    2017-12-01

    Intermediate-volatility and semi-volatile organic compounds (I/SVOCs) are major precursors to secondary organic aerosol, and contribute to tropospheric ozone formation. Their wide volatility range, chemical complexity, behavior in analytical systems, and trace concentrations present numerous hurdles to characterization. We present an integrated sampling-to-analysis system for the collection and offline analysis of trace gas-phase organic compounds with the goal of preserving and recovering analytes throughout sample collection, transport, storage, and thermal desorption for accurate analysis. Custom multi-bed adsorbent tubes are used to collect samples for offline analysis by advanced analytical detectors. The analytical instrumentation comprises an automated thermal desorption system that introduces analytes from the adsorbent tubes into a gas chromatograph, which is coupled with an electron ionization mass spectrometer (GC-EIMS) and other detectors. In order to optimize the collection and recovery for a wide range of analyte volatility and functionalization, we evaluated a variety of commercially-available materials, including Res-Sil beads, quartz wool, glass beads, Tenax TA, and silica gel. Key properties for optimization include inertness, versatile chemical capture, minimal affinity for water, and minimal artifacts or degradation byproducts; these properties were assessed with a diverse mix of traditionally-measured and functionalized analytes. Along with a focus on material selection, we provide recommendations spanning the entire sampling-and-analysis process to improve the accuracy of future comprehensive I/SVOC measurements, including oxygenated and other functionalized I/SVOCs. We demonstrate the performance of our system by providing results on speciated VOCs-SVOCs from indoor, outdoor, and chamber studies that establish the utility of our protocols and pave the way for precise laboratory characterization via a mix of detection methods.

  13. Multi-Agency Radiological Laboratory Analytical Protocols Manual (MARLAP)

    EPA Pesticide Factsheets

    The Multi-Agency Radiological Laboratory Analytical Protocols Manual (MARLAP) provides guidance for the planning, implementation and assessment phases of projects that require laboratory analysis of radionuclides.

  14. Rapid and high-resolution stable isotopic measurement of biogenic accretionary carbonate using an online CO2 laser ablation system: Standardization of the analytical protocol.

    PubMed

    Sreemany, Arpita; Bera, Melinda Kumar; Sarkar, Anindya

    2017-12-30

    The elaborate sampling and analytical protocol associated with conventional dual-inlet isotope ratio mass spectrometry has long hindered high-resolution climate studies from biogenic accretionary carbonates. Laser-based on-line systems, in comparison, produce rapid data, but suffer from unresolvable matrix effects. It is, therefore, necessary to resolve these matrix effects to take advantage of the automated laser-based method. Two marine bivalve shells (one aragonite and one calcite) and one fish otolith (aragonite) were first analysed using a CO 2 laser ablation system attached to a continuous flow isotope ratio mass spectrometer under different experimental conditions (different laser power, sample untreated vs vacuum roasted). The shells and the otolith were then micro-drilled and the isotopic compositions of the powders were measured in a dual-inlet isotope ratio mass spectrometer following the conventional acid digestion method. The vacuum-roasted samples (both aragonite and calcite) produced mean isotopic ratios (with a reproducibility of ±0.2 ‰ for both δ 18 O and δ 13 C values) almost identical to the values obtained using the conventional acid digestion method. As the isotopic ratio of the acid digested samples fall within the analytical precision (±0.2 ‰) of the laser ablation system, this suggests the usefulness of the method for studying the biogenic accretionary carbonate matrix. When using laser-based continuous flow isotope ratio mass spectrometry for the high-resolution isotopic measurements of biogenic carbonates, the employment of a vacuum-roasting step will reduce the matrix effect. This method will be of immense help to geologists and sclerochronologists in exploring short-term changes in climatic parameters (e.g. seasonality) in geological times. Copyright © 2017 John Wiley & Sons, Ltd.

  15. A communal catalogue reveals Earth's multiscale microbial diversity.

    PubMed

    Thompson, Luke R; Sanders, Jon G; McDonald, Daniel; Amir, Amnon; Ladau, Joshua; Locey, Kenneth J; Prill, Robert J; Tripathi, Anupriya; Gibbons, Sean M; Ackermann, Gail; Navas-Molina, Jose A; Janssen, Stefan; Kopylova, Evguenia; Vázquez-Baeza, Yoshiki; González, Antonio; Morton, James T; Mirarab, Siavash; Zech Xu, Zhenjiang; Jiang, Lingjing; Haroon, Mohamed F; Kanbar, Jad; Zhu, Qiyun; Jin Song, Se; Kosciolek, Tomasz; Bokulich, Nicholas A; Lefler, Joshua; Brislawn, Colin J; Humphrey, Gregory; Owens, Sarah M; Hampton-Marcell, Jarrad; Berg-Lyons, Donna; McKenzie, Valerie; Fierer, Noah; Fuhrman, Jed A; Clauset, Aaron; Stevens, Rick L; Shade, Ashley; Pollard, Katherine S; Goodwin, Kelly D; Jansson, Janet K; Gilbert, Jack A; Knight, Rob

    2017-11-23

    Our growing awareness of the microbial world's importance and diversity contrasts starkly with our limited understanding of its fundamental structure. Despite recent advances in DNA sequencing, a lack of standardized protocols and common analytical frameworks impedes comparisons among studies, hindering the development of global inferences about microbial life on Earth. Here we present a meta-analysis of microbial community samples collected by hundreds of researchers for the Earth Microbiome Project. Coordinated protocols and new analytical methods, particularly the use of exact sequences instead of clustered operational taxonomic units, enable bacterial and archaeal ribosomal RNA gene sequences to be followed across multiple studies and allow us to explore patterns of diversity at an unprecedented scale. The result is both a reference database giving global context to DNA sequence data and a framework for incorporating data from future studies, fostering increasingly complete characterization of Earth's microbial diversity.

  16. Protocol and standard operating procedures for common use in a worldwide multicenter study on reference values.

    PubMed

    Ozarda, Yesim; Ichihara, Kiyoshi; Barth, Julian H; Klee, George

    2013-05-01

    The reference intervals (RIs) given in laboratory reports have an important role in aiding clinicians in interpreting test results in reference to values of healthy populations. In this report, we present a proposed protocol and standard operating procedures (SOPs) for common use in conducting multicenter RI studies on a national or international scale. The protocols and consensus on their contents were refined through discussions in recent C-RIDL meetings. The protocol describes in detail (1) the scheme and organization of the study, (2) the target population, inclusion/exclusion criteria, ethnicity, and sample size, (3) health status questionnaire, (4) target analytes, (5) blood collection, (6) sample processing and storage, (7) assays, (8) cross-check testing, (9) ethics, (10) data analyses, and (11) reporting of results. In addition, the protocol proposes the common measurement of a panel of sera when no standard materials exist for harmonization of test results. It also describes the requirements of the central laboratory, including the method of cross-check testing between the central laboratory of each country and local laboratories. This protocol and the SOPs remain largely exploratory and may require a reevaluation from the practical point of view after their implementation in the ongoing worldwide study. The paper is mainly intended to be a basis for discussion in the scientific community.

  17. Recent advances in hopanoids analysis: Quantification protocols overview, main research targets and selected problems of complex data exploration.

    PubMed

    Zarzycki, Paweł K; Portka, Joanna K

    2015-09-01

    Pentacyclic triterpenoids, particularly hopanoids, are organism-specific compounds and are generally considered as useful biomarkers that allow fingerprinting and classification of biological, environmental and geological samples. Simultaneous quantification of various hopanoids together with battery of related non-polar and low-molecular mass compounds may provide principal information for geochemical and environmental research focusing on both modern and ancient investigations. Target compounds can be derived from microbial biomass, water columns, sediments, coals, crude fossils or rocks. This create number of analytical problems due to different composition of the analytical matrix and interfering compounds and therefore, proper optimization of quantification protocols for such biomarkers is still the challenge. In this work we summarizing typical analytical protocols that were recently applied for quantification of hopanoids like compounds from different samples. Main steps including components of interest extraction, pre-purification, fractionation, derivatization and quantification involving gas (1D and 2D) as well as liquid separation techniques (liquid-liquid extraction, solid-phase extraction, planar and low resolution column chromatography, high-performance liquid chromatography) are described and discussed from practical point of view, mainly based on the experimental papers that were published within last two years, where significant increase in hopanoids research was noticed. The second aim of this review is to describe the latest research trends concerning determination of hopanoids and related low-molecular mass lipids analyzed in various samples including sediments, rocks, coals, crude oils and plant fossils as well as stromatolites and microbial biomass cultivated under different conditions. It has been found that majority of the most recent papers are based on uni- or bivariate approach for complex data analysis. Data interpretation involves number of physicochemical parameters and hopanoids quantities or given biomarkers mass ratios derived from high-throughput separation and detection systems, typically GC-MS and HPLC-MS. Based on quantitative data reported in recently published experimental works it has been demonstrated that multivariate data analysis using e.g. principal components computations may significantly extend our knowledge concerning proper biomarkers selection and samples classification by means of hopanoids and related non-polar compounds. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Superhydrophobic Analyte Concentration Utilizing Colloid-Pillar Array SERS Substrates

    DOE PAGES

    Wallace, Ryan A.; Charlton, Jennifer J.; Kirchner, Teresa B.; ...

    2014-11-04

    In order to detect a few molecules present in a large sample it is important to know the trace components in the medicinal and environmental sample. Surface enhanced Raman spectroscopy (SERS) is a technique that can be utilized to detect molecules at very low absolute numbers. However, detection at trace concentration levels in real samples requires properly designed delivery and detection systems. Moreover, the following work involves superhydrophobic surfaces that includes silicon pillar arrays formed by lithographic and dewetting protocols. In order to generate the necessary plasmonic substrate for SERS detection, simple and flow stable Ag colloid was added tomore » the functionalized pillar array system via soaking. The pillars are used native and with hydrophobic modification. The pillars provide a means to concentrate analyte via superhydrophobic droplet evaporation effects. A 100-fold concentration of analyte was estimated, with a limit of detection of 2.9 10-12 M for mitoxantrone dihydrochloride. Additionally, analytes were delivered to the surface via a multiplex approach in order to demonstrate an ability to control droplet size and placement for scaled-up applications in real world applications. Finally, a concentration process involving transport and sequestration based on surface treatment selective wicking is demonstrated.« less

  19. Superhydrophobic Analyte Concentration Utilizing Colloid-Pillar Array SERS Substrates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wallace, Ryan A.; Charlton, Jennifer J.; Kirchner, Teresa B.

    In order to detect a few molecules present in a large sample it is important to know the trace components in the medicinal and environmental sample. Surface enhanced Raman spectroscopy (SERS) is a technique that can be utilized to detect molecules at very low absolute numbers. However, detection at trace concentration levels in real samples requires properly designed delivery and detection systems. Moreover, the following work involves superhydrophobic surfaces that includes silicon pillar arrays formed by lithographic and dewetting protocols. In order to generate the necessary plasmonic substrate for SERS detection, simple and flow stable Ag colloid was added tomore » the functionalized pillar array system via soaking. The pillars are used native and with hydrophobic modification. The pillars provide a means to concentrate analyte via superhydrophobic droplet evaporation effects. A 100-fold concentration of analyte was estimated, with a limit of detection of 2.9 10-12 M for mitoxantrone dihydrochloride. Additionally, analytes were delivered to the surface via a multiplex approach in order to demonstrate an ability to control droplet size and placement for scaled-up applications in real world applications. Finally, a concentration process involving transport and sequestration based on surface treatment selective wicking is demonstrated.« less

  20. U.S. Geological Survey nutrient preservation experiment; nutrient concentration data for surface-, ground-, and municipal-supply water samples and quality-assurance samples

    USGS Publications Warehouse

    Patton, Charles J.; Truitt, Earl P.

    1995-01-01

    This report is a compilation of analytical results from a study conducted at the U.S. Geological Survey, National Water Quality Laboratory (NWQL) in 1992 to assess the effectiveness of three field treatment protocols to stabilize nutrient concentra- tions in water samples stored for about 1 month at 4C. Field treatments tested were chilling, adjusting sample pH to less than 2 with sulfuric acid and chilling, and adding 52 milligrams of mercury (II) chloride per liter of sample and chilling. Field treatments of samples collected for determination of ammonium, nitrate plus nitrite, nitrite, dissolved Kjeldahl nitrogen, orthophosphate, and dissolved phosphorus included 0.45-micrometer membrane filtration. Only total Kjeldahl nitrogen and total phosphorus were determined in unfiltered samples. Data reported here pertain to water samples collected in April and May 1992 from 15 sites within the continental United States. Also included in this report are analytical results for nutrient concentrations in synthetic reference samples that were analyzed concurrently with real samples.

  1. Thermal/optical methods for elemental carbon quantification in soils and urban dusts: equivalence of different analysis protocols.

    PubMed

    Han, Yongming; Chen, Antony; Cao, Junji; Fung, Kochy; Ho, Fai; Yan, Beizhan; Zhan, Changlin; Liu, Suixin; Wei, Chong; An, Zhisheng

    2013-01-01

    Quantifying elemental carbon (EC) content in geological samples is challenging due to interferences of crustal, salt, and organic material. Thermal/optical analysis, combined with acid pretreatment, represents a feasible approach. However, the consistency of various thermal/optical analysis protocols for this type of samples has never been examined. In this study, urban street dust and soil samples from Baoji, China were pretreated with acids and analyzed with four thermal/optical protocols to investigate how analytical conditions and optical correction affect EC measurement. The EC values measured with reflectance correction (ECR) were found always higher and less sensitive to temperature program than the EC values measured with transmittance correction (ECT). A high-temperature method with extended heating times (STN120) showed the highest ECT/ECR ratio (0.86) while a low-temperature protocol (IMPROVE-550), with heating time adjusted for sample loading, showed the lowest (0.53). STN ECT was higher than IMPROVE ECT, in contrast to results from aerosol samples. A higher peak inert-mode temperature and extended heating times can elevate ECT/ECR ratios for pretreated geological samples by promoting pyrolyzed organic carbon (PyOC) removal over EC under trace levels of oxygen. Considering that PyOC within filter increases ECR while decreases ECT from the actual EC levels, simultaneous ECR and ECT measurements would constrain the range of EC loading and provide information on method performance. Further testing with standard reference materials of common environmental matrices supports the findings. Char and soot fractions of EC can be further separated using the IMPROVE protocol. The char/soot ratio was lower in street dusts (2.2 on average) than in soils (5.2 on average), most likely reflecting motor vehicle emissions. The soot concentrations agreed with EC from CTO-375, a pure thermal method.

  2. STATISTICAL ANALYSIS OF TANK 5 FLOOR SAMPLE RESULTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shine, E.

    2012-03-14

    Sampling has been completed for the characterization of the residual material on the floor of Tank 5 in the F-Area Tank Farm at the Savannah River Site (SRS), near Aiken, SC. The sampling was performed by Savannah River Remediation (SRR) LLC using a stratified random sampling plan with volume-proportional compositing. The plan consisted of partitioning the residual material on the floor of Tank 5 into three non-overlapping strata: two strata enclosed accumulations, and a third stratum consisted of a thin layer of material outside the regions of the two accumulations. Each of three composite samples was constructed from five primarymore » sample locations of residual material on the floor of Tank 5. Three of the primary samples were obtained from the stratum containing the thin layer of material, and one primary sample was obtained from each of the two strata containing an accumulation. This report documents the statistical analyses of the analytical results for the composite samples. The objective of the analysis is to determine the mean concentrations and upper 95% confidence (UCL95) bounds for the mean concentrations for a set of analytes in the tank residuals. The statistical procedures employed in the analyses were consistent with the Environmental Protection Agency (EPA) technical guidance by Singh and others [2010]. Savannah River National Laboratory (SRNL) measured the sample bulk density, nonvolatile beta, gross alpha, radionuclide, inorganic, and anion concentrations three times for each of the composite samples. The analyte concentration data were partitioned into three separate groups for further analysis: analytes with every measurement above their minimum detectable concentrations (MDCs), analytes with no measurements above their MDCs, and analytes with a mixture of some measurement results above and below their MDCs. The means, standard deviations, and UCL95s were computed for the analytes in the two groups that had at least some measurements above their MDCs. The identification of distributions and the selection of UCL95 procedures generally followed the protocol in Singh, Armbya, and Singh [2010]. When all of an analyte's measurements lie below their MDCs, only a summary of the MDCs can be provided. The measurement results reported by SRNL are listed in Appendix A, and the results of this analysis are reported in Appendix B. The data were generally found to follow a normal distribution, and to be homogeneous across composite samples.« less

  3. Statistical Analysis of Tank 5 Floor Sample Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shine, E. P.

    2013-01-31

    Sampling has been completed for the characterization of the residual material on the floor of Tank 5 in the F-Area Tank Farm at the Savannah River Site (SRS), near Aiken, SC. The sampling was performed by Savannah River Remediation (SRR) LLC using a stratified random sampling plan with volume-proportional compositing. The plan consisted of partitioning the residual material on the floor of Tank 5 into three non-overlapping strata: two strata enclosed accumulations, and a third stratum consisted of a thin layer of material outside the regions of the two accumulations. Each of three composite samples was constructed from five primarymore » sample locations of residual material on the floor of Tank 5. Three of the primary samples were obtained from the stratum containing the thin layer of material, and one primary sample was obtained from each of the two strata containing an accumulation. This report documents the statistical analyses of the analytical results for the composite samples. The objective of the analysis is to determine the mean concentrations and upper 95% confidence (UCL95) bounds for the mean concentrations for a set of analytes in the tank residuals. The statistical procedures employed in the analyses were consistent with the Environmental Protection Agency (EPA) technical guidance by Singh and others [2010]. Savannah River National Laboratory (SRNL) measured the sample bulk density, nonvolatile beta, gross alpha, and the radionuclide1, elemental, and chemical concentrations three times for each of the composite samples. The analyte concentration data were partitioned into three separate groups for further analysis: analytes with every measurement above their minimum detectable concentrations (MDCs), analytes with no measurements above their MDCs, and analytes with a mixture of some measurement results above and below their MDCs. The means, standard deviations, and UCL95s were computed for the analytes in the two groups that had at least some measurements above their MDCs. The identification of distributions and the selection of UCL95 procedures generally followed the protocol in Singh, Armbya, and Singh [2010]. When all of an analyte's measurements lie below their MDCs, only a summary of the MDCs can be provided. The measurement results reported by SRNL are listed, and the results of this analysis are reported. The data were generally found to follow a normal distribution, and to be homogenous across composite samples.« less

  4. Statistical Analysis Of Tank 5 Floor Sample Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shine, E. P.

    2012-08-01

    Sampling has been completed for the characterization of the residual material on the floor of Tank 5 in the F-Area Tank Farm at the Savannah River Site (SRS), near Aiken, SC. The sampling was performed by Savannah River Remediation (SRR) LLC using a stratified random sampling plan with volume-proportional compositing. The plan consisted of partitioning the residual material on the floor of Tank 5 into three non-overlapping strata: two strata enclosed accumulations, and a third stratum consisted of a thin layer of material outside the regions of the two accumulations. Each of three composite samples was constructed from five primarymore » sample locations of residual material on the floor of Tank 5. Three of the primary samples were obtained from the stratum containing the thin layer of material, and one primary sample was obtained from each of the two strata containing an accumulation. This report documents the statistical analyses of the analytical results for the composite samples. The objective of the analysis is to determine the mean concentrations and upper 95% confidence (UCL95) bounds for the mean concentrations for a set of analytes in the tank residuals. The statistical procedures employed in the analyses were consistent with the Environmental Protection Agency (EPA) technical guidance by Singh and others [2010]. Savannah River National Laboratory (SRNL) measured the sample bulk density, nonvolatile beta, gross alpha, and the radionuclide, elemental, and chemical concentrations three times for each of the composite samples. The analyte concentration data were partitioned into three separate groups for further analysis: analytes with every measurement above their minimum detectable concentrations (MDCs), analytes with no measurements above their MDCs, and analytes with a mixture of some measurement results above and below their MDCs. The means, standard deviations, and UCL95s were computed for the analytes in the two groups that had at least some measurements above their MDCs. The identification of distributions and the selection of UCL95 procedures generally followed the protocol in Singh, Armbya, and Singh [2010]. When all of an analyte's measurements lie below their MDCs, only a summary of the MDCs can be provided. The measurement results reported by SRNL are listed in Appendix A, and the results of this analysis are reported in Appendix B. The data were generally found to follow a normal distribution, and to be homogenous across composite samples.« less

  5. RNA Cap Methyltransferase Activity Assay

    PubMed Central

    Trotman, Jackson B.; Schoenberg, Daniel R.

    2018-01-01

    Methyltransferases that methylate the guanine-N7 position of the mRNA 5′ cap structure are ubiquitous among eukaryotes and commonly encoded by viruses. Here we provide a detailed protocol for the biochemical analysis of RNA cap methyltransferase activity of biological samples. This assay involves incubation of cap-methyltransferase-containing samples with a [32P]G-capped RNA substrate and S-adenosylmethionine (SAM) to produce RNAs with N7-methylated caps. The extent of cap methylation is then determined by P1 nuclease digestion, thin-layer chromatography (TLC), and phosphorimaging. The protocol described here includes additional steps for generating the [32P]G-capped RNA substrate and for preparing nuclear and cytoplasmic extracts from mammalian cells. This assay is also applicable to analyzing the cap methyltransferase activity of other biological samples, including recombinant protein preparations and fractions from analytical separations and immunoprecipitation/pulldown experiments. PMID:29644259

  6. Instrumental neutron activation analysis for studying size-fractionated aerosols

    NASA Astrophysics Data System (ADS)

    Salma, Imre; Zemplén-Papp, Éva

    1999-10-01

    Instrumental neutron activation analysis (INAA) was utilized for studying aerosol samples collected into a coarse and a fine size fraction on Nuclepore polycarbonate membrane filters. As a result of the panoramic INAA, 49 elements were determined in an amount of about 200-400 μg of particulate matter by two irradiations and four γ-spectrometric measurements. The analytical calculations were performed by the absolute ( k0) standardization method. The calibration procedures, application protocol and the data evaluation process are described and discussed. They make it possible now to analyse a considerable number of samples, with assuring the quality of the results. As a means of demonstrating the system's analytical capabilities, the concentration ranges, median or mean atmospheric concentrations and detection limits are presented for an extensive series of aerosol samples collected within the framework of an urban air pollution study in Budapest. For most elements, the precision of the analysis was found to be beyond the uncertainty represented by the sampling techniques and sample variability.

  7. Apheresis product identification in the transplant center: development of point-of-care protocols for extended blood typing of stem cell apheresis products.

    PubMed

    Cummerow, C; Schwind, P; Spicher, M; Spohn, G; Geisen, C; Seifried, E; Bönig, H

    2012-06-01

    Transfusion of the 'wrong' stem cell product would almost inevitably be lethal, yet assays to confirm the contents of the product bag, except by checking labels and paperwork, are lacking. To increase the likelihood that a product mix-up would be detected in the transplant center, we developed a simple protocol for extended blood typing and hence, for confirmation of donor/product identity, on a tube segment. Apheresis samples were applied, directly or after erythrocyte enrichment, to commercially available blood typing assays, including lateral flow cards and gel agglutination cards. Without sample modification, low hematocrit and high leukocyte count obviated definitive blood typing. Using the most simple erythrocyte enrichment protocol, that is, centrifugation, reliable blood group analysis became possible with either assay. Other, more cumbersome pre-analytical protocols were also successful but provided no advantage. The preferred method was validated on 100 samples; ABD was correctly identified in 100% of cases. Of the other Rh Ags, all except two 'small e', in both cases in heterozygous individuals, were detected; there were no false positives. A simple, inexpensive point-of-care assay for extended blood typing of apheresis products is available, which can reduce the fatal risk of administering the wrong stem cell product.

  8. Measurement Protocols for In situ Analysis of Organic Compounds at Mars and Comets

    NASA Technical Reports Server (NTRS)

    Mahaffy, P. R.; Brinckerhuff, W. B.; Buch, A.; Cabane, M.; Coll, P.; Demick, J.; Glavin, D. P.; Navarro-Gonzalez, R.

    2005-01-01

    The determination of the abundance and chemical and isotopic composition of organic molecules in comets and those that might be found in protected environments at Mars is a first step toward understanding prebiotic chemistries on these solar system bodies. While future sample return missions from Mars and comets will enable detailed chemical and isotopic analysis with a wide range of analytical techniques, precursor insitu investigations can complement these missions and facilitate the identification of optimal sites for sample return. Robust automated experiments that make efficient use of limited spacecraft power, mass, and data volume resources are required for use by insitu missions. Within these constraints we continue to explore a range of instrument techniques and measurement protocols that can maximize the return from such insitu investigations.

  9. Measurement Protocols for In Situ Analysis of Organic Compounds at Mars and Comets

    NASA Technical Reports Server (NTRS)

    Mahaffy, P. R.; Brinckerhoff, W. B.; Buch, A.; Cabane, M.; Coll, P.; Demick, J.; Glavin, D. P.; Navarro-Gonzalez, R.

    2005-01-01

    The determination of the abundance and chemical and isotopic composition of organic molecules in comets and those that might be found in protected environments at Mars is a first step toward understanding prebiotic chemistries on these solar system bodies. While future sample return missions from Mars and comets will enable detailed chemical and isotopic analysis with a wide range of analytical techniques, precursor insitu investigations can complement these missions and facilitate the identification of optimal sites for sample return. Robust automated experiments that make efficient use of limited spacecraft power, mass, and data volume resources are required for use by insitu missions. Within these constraints we continue to explore a range of instrument techniques and measurement protocols that can maximize the return from such insitu investigations.

  10. Thermal-vacuum response of polymer matrix composites in space

    NASA Technical Reports Server (NTRS)

    Tennyson, R. C.; Matthews, R.

    1993-01-01

    This report describes a thermal-vacuum outgassing model and test protocol for predicting outgassing times and dimensional changes for polymer matrix composites. Experimental results derived from 'control' samples are used to provide the basis for analytical predictions to compare with the outgassing response of Long Duration Exposure Facility (LDEF) flight samples. Coefficient of thermal expansion (CTE) data are also presented. In addition, an example is given illustrating the dimensional change of a 'zero' CTE laminate due to moisture outgassing.

  11. A novel method for quantification of gemcitabine and its metabolites 2',2'-difluorodeoxyuridine and gemcitabine triphosphate in tumour tissue by LC-MS/MS: comparison with (19)F NMR spectroscopy.

    PubMed

    Bapiro, Tashinga E; Richards, Frances M; Goldgraben, Mae A; Olive, Kenneth P; Madhu, Basetti; Frese, Kristopher K; Cook, Natalie; Jacobetz, Michael A; Smith, Donna-Michelle; Tuveson, David A; Griffiths, John R; Jodrell, Duncan I

    2011-11-01

    To develop a sensitive analytical method to quantify gemcitabine (2',2'-difluorodeoxycytidine, dFdC) and its metabolites 2',2'-difluorodeoxyuridine (dFdU) and 2',2'-difluorodeoxycytidine-5'-triphosphate (dFdCTP) simultaneously from tumour tissue. Pancreatic ductal adenocarcinoma tumour tissue from genetically engineered mouse models of pancreatic cancer (KP ( FL/FL ) C and KP ( R172H/+) C) was collected after dosing the mice with gemcitabine. (19)F NMR spectroscopy and LC-MS/MS protocols were optimised to detect gemcitabine and its metabolites in homogenates of the tumour tissue. A (19)F NMR protocol was developed, which was capable of distinguishing the three analytes in tumour homogenates. However, it required at least 100 mg of the tissue in question and a long acquisition time per sample, making it impractical for use in large PK/PD studies or clinical trials. The LC-MS/MS protocol was developed using porous graphitic carbon to separate the analytes, enabling simultaneous detection of all three analytes from as little as 10 mg of tissue, with a sensitivity for dFdCTP of 0.2 ng/mg tissue. Multiple pieces of tissue from single tumours were analysed, showing little intra-tumour variation in the concentrations of dFdC or dFdU (both intra- and extra-cellular). Intra-tumoural variation was observed in the concentration of dFdCTP, an intra-cellular metabolite, which may reflect regions of different cellularity within a tumour. We have developed a sensitive LC-MS/MS method capable of quantifying gemcitabine, dFdU and dFdCTP in pancreatic tumour tissue. The requirement for only 10 mg of tissue enables this protocol to be used to analyse multiple areas from a single tumour and to spare tissue for additional pharmacodynamic assays.

  12. Analytical control test plan and microbiological methods for the water recovery test

    NASA Technical Reports Server (NTRS)

    Traweek, M. S. (Editor); Tatara, J. D. (Editor)

    1994-01-01

    Qualitative and quantitative laboratory results are important to the decision-making process. In some cases, they may represent the only basis for deciding between two or more given options or processes. Therefore, it is essential that handling of laboratory samples and analytical operations employed are performed at a deliberate level of conscientious effort. Reporting erroneous results can lead to faulty interpretations and result in misinformed decisions. This document provides analytical control specifications which will govern future test procedures related to all Water Recovery Test (WRT) Phase 3 activities to be conducted at the National Aeronautics and Space Administration/Marshall Space Flight Center (NASA/MSFC). This document addresses the process which will be used to verify analytical data generated throughout the test period, and to identify responsibilities of key personnel and participating laboratories, the chains of communication to be followed, and ensure that approved methodology and procedures are used during WRT activities. This document does not outline specifics, but provides a minimum guideline by which sampling protocols, analysis methodologies, test site operations, and laboratory operations should be developed.

  13. Size analysis of polyglutamine protein aggregates using fluorescence detection in an analytical ultracentrifuge.

    PubMed

    Polling, Saskia; Hatters, Danny M; Mok, Yee-Foong

    2013-01-01

    Defining the aggregation process of proteins formed by poly-amino acid repeats in cells remains a challenging task due to a lack of robust techniques for their isolation and quantitation. Sedimentation velocity methodology using fluorescence detected analytical ultracentrifugation is one approach that can offer significant insight into aggregation formation and kinetics. While this technique has traditionally been used with purified proteins, it is now possible for substantial information to be collected with studies using cell lysates expressing a GFP-tagged protein of interest. In this chapter, we describe protocols for sample preparation and setting up the fluorescence detection system in an analytical ultracentrifuge to perform sedimentation velocity experiments on cell lysates containing aggregates formed by poly-amino acid repeat proteins.

  14. Tracking Matrix Effects in the Analysis of DNA Adducts of Polycyclic Aromatic Hydrocarbons

    PubMed Central

    Klaene, Joshua J.; Flarakos, Caroline; Glick, James; Barret, Jennifer T.; Zarbl, Helmut; Vouros, Paul

    2015-01-01

    LC-MS using electrospray ionization is currently the method of choice in bio-organic analysis covering a wide range of applications in a broad spectrum of biological media. The technique is noted for its high sensitivity but one major limitation which hinders achievement of its optimal sensitivity is the signal suppression due to matrix inferences introduced by the presence of co-extracted compounds during the sample preparation procedure. The analysis of DNA adducts of common environmental carcinogens is particularly sensitive to such matrix effects as sample preparation is a multistep process which involves “contamination” of the sample due to the addition of enzymes and other reagents for digestion of the DNA in order to isolate the analyte(s). This problem is further exacerbated by the need to reach low levels of quantitation (LOQ in the ppb level) while also working with limited (2-5 μg) quantities of sample. We report here on the systematic investigation of ion signal suppression contributed by each individual step involved in the sample preparation associated with the analysis of DNA adducts of polycyclic aromatic hydrocarbon (PAH) using as model analyte dG-BaP, the deoxyguanosine adduct of benzo[a]pyrene (BaP). The individual matrix contribution of each one of these sources to analyte signal was systematically addressed as were any interactive effects. The information was used to develop a validated analytical protocol for the target biomarker at levels typically encountered in vivo using as little as 2 μg of DNA and applied to a dose response study using a metabolically competent cell line. PMID:26607319

  15. Can cloud point-based enrichment, preservation, and detection methods help to bridge gaps in aquatic nanometrology?

    PubMed

    Duester, Lars; Fabricius, Anne-Lena; Jakobtorweihen, Sven; Philippe, Allan; Weigl, Florian; Wimmer, Andreas; Schuster, Michael; Nazar, Muhammad Faizan

    2016-11-01

    Coacervate-based techniques are intensively used in environmental analytical chemistry to enrich and extract different kinds of analytes. Most methods focus on the total content or the speciation of inorganic and organic substances. Size fractionation is less commonly addressed. Within coacervate-based techniques, cloud point extraction (CPE) is characterized by a phase separation of non-ionic surfactants dispersed in an aqueous solution when the respective cloud point temperature is exceeded. In this context, the feature article raises the following question: May CPE in future studies serve as a key tool (i) to enrich and extract nanoparticles (NPs) from complex environmental matrices prior to analyses and (ii) to preserve the colloidal status of unstable environmental samples? With respect to engineered NPs, a significant gap between environmental concentrations and size- and element-specific analytical capabilities is still visible. CPE may support efforts to overcome this "concentration gap" via the analyte enrichment. In addition, most environmental colloidal systems are known to be unstable, dynamic, and sensitive to changes of the environmental conditions during sampling and sample preparation. This delivers a so far unsolved "sample preparation dilemma" in the analytical process. The authors are of the opinion that CPE-based methods have the potential to preserve the colloidal status of these instable samples. Focusing on NPs, this feature article aims to support the discussion on the creation of a convention called the "CPE extractable fraction" by connecting current knowledge on CPE mechanisms and on available applications, via the uncertainties visible and modeling approaches available, with potential future benefits from CPE protocols.

  16. Difficulties in fumonisin determination: the issue of hidden fumonisins.

    PubMed

    Dall'Asta, Chiara; Mangia, Mattia; Berthiller, Franz; Molinelli, Alexandra; Sulyok, Michael; Schuhmacher, Rainer; Krska, Rudolf; Galaverna, Gianni; Dossena, Arnaldo; Marchelli, Rosangela

    2009-11-01

    In this paper, the results obtained by five independent methods for the quantification of fumonisins B(1), B(2), and B(3) in raw maize are reported. Five naturally contaminated maize samples and a reference material were analyzed in three different laboratories. Although each method was validated and common calibrants were used, a poor agreement about fumonisin contamination levels was obtained. In order to investigate the interactions among analyte and matrix leading to this lack of consistency, the occurrence of fumonisin derivatives was checked. Significant amounts of hidden fumonisins were detected for all the considered samples. Furthermore, the application of an in vitro digestion protocol to raw maize allowed for a higher recovery of native fumonisins, suggesting that the interaction occurring among analytes and matrix macromolecules is associative rather than covalent. Depending on the analytical method as well as the maize sample, only 37-68% of the total fumonisin concentrations were found to be extractable from the samples. These results are particularly impressive and significant in the case of the certified reference material, underlying the actual difficulties in ascertaining the trueness of a method for fumonisin determination, opening thus an important issue for risk assessment.

  17. Working towards accreditation by the International Standards Organization 15189 Standard: how to validate an in-house developed method an example of lead determination in whole blood by electrothermal atomic absorption spectrometry.

    PubMed

    Garcia Hejl, Carine; Ramirez, Jose Manuel; Vest, Philippe; Chianea, Denis; Renard, Christophe

    2014-09-01

    Laboratories working towards accreditation by the International Standards Organization (ISO) 15189 standard are required to demonstrate the validity of their analytical methods. The different guidelines set by various accreditation organizations make it difficult to provide objective evidence that an in-house method is fit for the intended purpose. Besides, the required performance characteristics tests and acceptance criteria are not always detailed. The laboratory must choose the most suitable validation protocol and set the acceptance criteria. Therefore, we propose a validation protocol to evaluate the performance of an in-house method. As an example, we validated the process for the detection and quantification of lead in whole blood by electrothermal absorption spectrometry. The fundamental parameters tested were, selectivity, calibration model, precision, accuracy (and uncertainty of measurement), contamination, stability of the sample, reference interval, and analytical interference. We have developed a protocol that has been applied successfully to quantify lead in whole blood by electrothermal atomic absorption spectrometry (ETAAS). In particular, our method is selective, linear, accurate, and precise, making it suitable for use in routine diagnostics.

  18. Capillary ion chromatography with on-column focusing for ultra-trace analysis of methanesulfonate and inorganic anions in limited volume Antarctic ice core samples.

    PubMed

    Rodriguez, Estrella Sanz; Poynter, Sam; Curran, Mark; Haddad, Paul R; Shellie, Robert A; Nesterenko, Pavel N; Paull, Brett

    2015-08-28

    Preservation of ionic species within Antarctic ice yields a unique proxy record of the Earth's climate history. Studies have been focused until now on two proxies: the ionic components of sea salt aerosol and methanesulfonic acid. Measurement of the all of the major ionic species in ice core samples is typically carried out by ion chromatography. Former methods, whilst providing suitable detection limits, have been based upon off-column preconcentration techniques, requiring larger sample volumes, with potential for sample contamination and/or carryover. Here, a new capillary ion chromatography based analytical method has been developed for quantitative analysis of limited volume Antarctic ice core samples. The developed analytical protocol applies capillary ion chromatography (with suppressed conductivity detection) and direct on-column sample injection and focusing, thus eliminating the requirement for off-column sample preconcentration. This limits the total sample volume needed to 300μL per analysis, allowing for triplicate sample analysis with <1mL of sample. This new approach provides a reliable and robust analytical method for the simultaneous determination of organic and inorganic anions, including fluoride, methanesulfonate, chloride, sulfate and nitrate anions. Application to composite ice-core samples is demonstrated, with coupling of the capillary ion chromatograph to high resolution mass spectrometry used to confirm the presence and purity of the observed methanesulfonate peak. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Automation of dimethylation after guanidination labeling chemistry and its compatibility with common buffers and surfactants for mass spectrometry-based shotgun quantitative proteome analysis.

    PubMed

    Lo, Andy; Tang, Yanan; Chen, Lu; Li, Liang

    2013-07-25

    Isotope labeling liquid chromatography-mass spectrometry (LC-MS) is a major analytical platform for quantitative proteome analysis. Incorporation of isotopes used to distinguish samples plays a critical role in the success of this strategy. In this work, we optimized and automated a chemical derivatization protocol (dimethylation after guanidination, 2MEGA) to increase the labeling reproducibility and reduce human intervention. We also evaluated the reagent compatibility of this protocol to handle biological samples in different types of buffers and surfactants. A commercially available liquid handler was used for reagent dispensation to minimize analyst intervention and at least twenty protein digest samples could be prepared in a single run. Different front-end sample preparation methods for protein solubilization (SDS, urea, Rapigest™, and ProteaseMAX™) and two commercially available cell lysis buffers were evaluated for compatibility with the automated protocol. It was found that better than 94% desired labeling could be obtained in all conditions studied except urea, where the rate was reduced to about 92% due to carbamylation on the peptide amines. This work illustrates the automated 2MEGA labeling process can be used to handle a wide range of protein samples containing various reagents that are often encountered in protein sample preparation for quantitative proteome analysis. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Filter Membrane Effects on Water-Extractable Phosphorus Concentrations from Soil.

    PubMed

    Norby, Jessica; Strawn, Daniel; Brooks, Erin

    2018-03-01

    To accurately assess P concentrations in soil extracts, standard laboratory practices for monitoring P concentrations are needed. Water-extractable P is a common analytical test to determine P availability for leaching from soils, and it is used to determine best management practices. Most P analytical tests require filtration through a filter membrane with 0.45-μm pore size to distinguish between particulate and dissolved P species. However, filter membrane type is rarely specified in method protocols, and many different types of membranes are available. In this study, three common filter membrane materials (polyether sulfone, nylon, and nitrocellulose), all with 0.45-μm pore sizes, were tested for analytical differences in total P concentrations and dissolved reactive P (DRP) concentrations in water extracts from six soils sampled from two regions. Three of the extracts from the six soil samples had different total P concentrations for all three membrane types. The other three soil extracts had significantly different total P results from at least one filter membrane type. Total P concentration differences were as great as 35%. The DRP concentrations in the extracts were dependent on filter type in five of the six soil types. Results from this research show that filter membrane type is an important parameter that affects concentrations of total P and DRP from soil extracts. Thus, membrane type should be specified in soil extraction protocols. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  1. Simultaneous determination of thirteen different steroid hormones using micro UHPLC-MS/MS with on-line SPE system.

    PubMed

    Márta, Zoltán; Bobály, Balázs; Fekete, Jenő; Magda, Balázs; Imre, Tímea; Mészáros, Katalin Viola; Bálint, Mária; Szabó, Pál Tamás

    2018-02-20

    Ultratrace analysis of sample components requires excellent analytical performance in terms of limits of quantitation (LOQ). Micro UHPLC coupled to sensitive tandem mass spectrometry provides state of the art solution for such analytical problems. Using on-line SPE with column switching on a micro UHPLC-MS/MS system allowed to decrease LOQ without any complex sample preparation protocol. The presented method is capable of reaching satisfactory low LOQ values for analysis of thirteen different steroid molecules from human plasma without the most commonly used off-line SPE or compound derivatization. Steroids were determined by using two simple sample preparation methods, based on lower and higher plasma steroid concentrations. In the first method, higher analyte concentrations were directly determined after protein precipitation with methanol. The organic phase obtained from the precipitation was diluted with water and directly injected into the LC-MS system. In the second method, low steroid levels were determined by concentrating the organic phase after steroid extraction. In this case, analytes were extracted with ethyl acetate and reconstituted in 90/10 water/acetonitrile following evaporation to dryness. This step provided much lower LOQs, outperforming previously published values. The method has been validated and subsequently applied to clinical laboratory measurement. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Superhydrophobic analyte concentration utilizing colloid-pillar array SERS substrates.

    PubMed

    Wallace, Ryan A; Charlton, Jennifer J; Kirchner, Teresa B; Lavrik, Nickolay V; Datskos, Panos G; Sepaniak, Michael J

    2014-12-02

    The ability to detect a few molecules present in a large sample is of great interest for the detection of trace components in both medicinal and environmental samples. Surface enhanced Raman spectroscopy (SERS) is a technique that can be utilized to detect molecules at very low absolute numbers. However, detection at trace concentration levels in real samples requires properly designed delivery and detection systems. The following work involves superhydrophobic surfaces that have as a framework deterministic or stochastic silicon pillar arrays formed by lithographic or metal dewetting protocols, respectively. In order to generate the necessary plasmonic substrate for SERS detection, simple and flow stable Ag colloid was added to the functionalized pillar array system via soaking. Native pillars and pillars with hydrophobic modification are used. The pillars provide a means to concentrate analyte via superhydrophobic droplet evaporation effects. A ≥ 100-fold concentration of analyte was estimated, with a limit of detection of 2.9 × 10(-12) M for mitoxantrone dihydrochloride. Additionally, analytes were delivered to the surface via a multiplex approach in order to demonstrate an ability to control droplet size and placement for scaled-up uses in real world applications. Finally, a concentration process involving transport and sequestration based on surface treatment selective wicking is demonstrated.

  3. Determination of a risk management primer at petroleum-contaminated sites: developing new human health risk assessment strategy.

    PubMed

    Park, In-Sun; Park, Jae-Woo

    2011-01-30

    Total petroleum hydrocarbon (TPH) is an important environmental contaminant that is toxic to human and environmental receptors. However, human health risk assessment for petroleum, oil, and lubricant (POL)-contaminated sites is especially challenging because TPH is not a single compound, but rather a mixture of numerous substances. To address this concern, this study recommends a new human health risk assessment strategy for POL-contaminated sites. The strategy is based on a newly modified TPH fractionation method and includes an improved analytical protocol. The proposed TPH fractionation method is composed of ten fractions (e.g., aliphatic and aromatic EC8-10, EC10-12, EC12-16, EC16-22 and EC22-40). Physicochemical properties and toxicity values of each fraction were newly defined in this study. The stepwise ultrasonication-based analytical process was established to measure TPH fractions. Analytical results were compared with those from the TPH Criteria Working Group (TPHCWG) Direct Method. Better analytical efficiencies in TPH, aliphatic, and aromatic fractions were achieved when contaminated soil samples were analyzed with the new analytical protocol. Finally, a human health risk assessment was performed based on the developed tiered risk assessment framework. Results showed that a detailed quantitative risk assessment should be conducted to determine scientifically and economically appropriate cleanup target levels, although the phase II process is useful for determining the potency of human health risks posed by POL-contamination. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Preliminary Validation of Direct Detection of Foot-And-Mouth Disease Virus within Clinical Samples Using Reverse Transcription Loop-Mediated Isothermal Amplification Coupled with a Simple Lateral Flow Device for Detection

    PubMed Central

    Waters, Ryan A.; Fowler, Veronica L.; Armson, Bryony; Nelson, Noel; Gloster, John; Paton, David J.; King, Donald P.

    2014-01-01

    Rapid, field-based diagnostic assays are desirable tools for the control of foot-and-mouth disease (FMD). Current approaches involve either; 1) Detection of FMD virus (FMDV) with immuochromatographic antigen lateral flow devices (LFD), which have relatively low analytical sensitivity, or 2) portable RT-qPCR that has high analytical sensitivity but is expensive. Loop-mediated isothermal amplification (LAMP) may provide a platform upon which to develop field based assays without these drawbacks. The objective of this study was to modify an FMDV-specific reverse transcription–LAMP (RT-LAMP) assay to enable detection of dual-labelled LAMP products with an LFD, and to evaluate simple sample processing protocols without nucleic acid extraction. The limit of detection of this assay was demonstrated to be equivalent to that of a laboratory based real-time RT-qPCR assay and to have a 10,000 fold higher analytical sensitivity than the FMDV-specific antigen LFD currently used in the field. Importantly, this study demonstrated that FMDV RNA could be detected from epithelial suspensions without the need for prior RNA extraction, utilising a rudimentary heat source for amplification. Once optimised, this RT-LAMP-LFD protocol was able to detect multiple serotypes from field epithelial samples, in addition to detecting FMDV in the air surrounding infected cattle, pigs and sheep, including pre-clinical detection. This study describes the development and evaluation of an assay format, which may be used as a future basis for rapid and low cost detection of FMDV. In addition it provides providing “proof of concept” for the future use of LAMP assays to tackle other challenging diagnostic scenarios encompassing veterinary and human health. PMID:25165973

  5. Chemistry of precipitation, streamwater, and lakewater from the Hubbard Brook Ecosystem Study: a record of sampling protocols and analytical procedures

    Treesearch

    Donald C. Buso; Gene E. Likens; John S. Eaton

    2000-01-01

    The Hubbard Brook Ecosystem Study (HBES), begun in 1963, is a long-term effort to understand the structure, function and change in forest watersheds and associated aquatic ecosystems at the Hubbard Brook Experimental Forest in New Hampshire. Chemical analyses of streamwater and precipitation collections began in 1963, and analyses of lakewater collections began in 1967...

  6. MASTER ANALYTICAL SCHEME FOR ORGANIC COMPOUNDS IN WATER: PART 1. PROTOCOLS

    EPA Science Inventory

    A Master Analytical Scheme (MAS) has been developed for the analysis of volatile (gas chromatographable) organic compounds in water. In developing the MAS, it was necessary to evaluate and modify existing analysis procedures and develop new techniques to produce protocols that pr...

  7. Comparison of three sampling and analytical methods for the determination of airborne hexavalent chromium.

    PubMed

    Boiano, J M; Wallace, M E; Sieber, W K; Groff, J H; Wang, J; Ashley, K

    2000-08-01

    A field study was conducted with the goal of comparing the performance of three recently developed or modified sampling and analytical methods for the determination of airborne hexavalent chromium (Cr(VI)). The study was carried out in a hard chrome electroplating facility and in a jet engine manufacturing facility where airborne Cr(VI) was expected to be present. The analytical methods evaluated included two laboratory-based procedures (OSHA Method ID-215 and NIOSH Method 7605) and a field-portable method (NIOSH Method 7703). These three methods employ an identical sampling methodology: collection of Cr(VI)-containing aerosol on a polyvinyl chloride (PVC) filter housed in a sampling cassette, which is connected to a personal sampling pump calibrated at an appropriate flow rate. The basis of the analytical methods for all three methods involves extraction of the PVC filter in alkaline buffer solution, chemical isolation of the Cr(VI) ion, complexation of the Cr(VI) ion with 1,5-diphenylcarbazide, and spectrometric measurement of the violet chromium diphenylcarbazone complex at 540 nm. However, there are notable specific differences within the sample preparation procedures used in three methods. To assess the comparability of the three measurement protocols, a total of 20 side-by-side air samples were collected, equally divided between a chromic acid electroplating operation and a spray paint operation where water soluble forms of Cr(VI) were used. A range of Cr(VI) concentrations from 0.6 to 960 microg m(-3), with Cr(VI) mass loadings ranging from 0.4 to 32 microg, was measured at the two operations. The equivalence of the means of the log-transformed Cr(VI) concentrations obtained from the different analytical methods was compared. Based on analysis of variance (ANOVA) results, no statistically significant differences were observed between mean values measured using each of the three methods. Small but statistically significant differences were observed between results obtained from performance evaluation samples for the NIOSH field method and the OSHA laboratory method.

  8. Affinity Proteomics for Fast, Sensitive, Quantitative Analysis of Proteins in Plasma.

    PubMed

    O'Grady, John P; Meyer, Kevin W; Poe, Derrick N

    2017-01-01

    The improving efficacy of many biological therapeutics and identification of low-level biomarkers are driving the analytical proteomics community to deal with extremely high levels of sample complexity relative to their analytes. Many protein quantitation and biomarker validation procedures utilize an immunoaffinity enrichment step to purify the sample and maximize the sensitivity of the corresponding liquid chromatography tandem mass spectrometry measurements. In order to generate surrogate peptides with better mass spectrometric properties, protein enrichment is followed by a proteolytic cleavage step. This is often a time-consuming multistep process. Presented here is a workflow which enables rapid protein enrichment and proteolytic cleavage to be performed in a single, easy-to-use reactor. Using this strategy Klotho, a low-abundance biomarker found in plasma, can be accurately quantitated using a protocol that takes under 5 h from start to finish.

  9. MASTER ANALYTICAL SCHEME FOR ORGANIC COMPOUNDS IN WATER. PART 2. APPENDICES TO PROTOCOLS

    EPA Science Inventory

    A Master Analytical Scheme (MAS) has been developed for the analysis of volatile (gas chromatographable) organic compounds in water. In developing the MAS, it was necessary to evaluate and modify existing analysis procedures and develop new techniques to produce protocols that pr...

  10. Searching for the best real-time RT-PCRs to detect Zika virus infections: the importance of comparing several protocols.

    PubMed

    de Moraes, F M; Espósito, D L A; Klein, T M; da Fonseca, B A L

    2018-01-01

    Clinical manifestations of Zika, dengue, and chikungunya virus infections are very similar, making it difficult to reach a diagnosis based only on clinical grounds. In addition, there is an intense cross-reactivity between antibodies directed to Zika virus and other flaviviruses, and an accurate Zika diagnosis is best achieved by real-time RT-PCR. However, some real-time RT-PCR show better performance than others. To reach the best possible Zika diagnosis, the analytic sensitivity of some probe-based real-time RT-PCR amplifying Zika virus RNA was evaluated in spiked and clinical samples. We evaluated primers and probes to detect Zika virus, which had been published before, and tested sensitivity using serum spiked and patient samples by real-time RT-PCR. When tested against spiked samples, the previously described primers showed different sensitivity, with very similar results when samples from patients (serum and urine) were analyzed. Real-time RT-PCR designed to amplify Zika virus NS1 showed the best analytical sensitivity for all samples.

  11. Thermal/Optical Methods for Elemental Carbon Quantification in Soils and Urban Dusts: Equivalence of Different Analysis Protocols

    PubMed Central

    Han, Yongming; Chen, Antony; Cao, Junji; Fung, Kochy; Ho, Fai; Yan, Beizhan; Zhan, Changlin; Liu, Suixin; Wei, Chong; An, Zhisheng

    2013-01-01

    Quantifying elemental carbon (EC) content in geological samples is challenging due to interferences of crustal, salt, and organic material. Thermal/optical analysis, combined with acid pretreatment, represents a feasible approach. However, the consistency of various thermal/optical analysis protocols for this type of samples has never been examined. In this study, urban street dust and soil samples from Baoji, China were pretreated with acids and analyzed with four thermal/optical protocols to investigate how analytical conditions and optical correction affect EC measurement. The EC values measured with reflectance correction (ECR) were found always higher and less sensitive to temperature program than the EC values measured with transmittance correction (ECT). A high-temperature method with extended heating times (STN120) showed the highest ECT/ECR ratio (0.86) while a low-temperature protocol (IMPROVE-550), with heating time adjusted for sample loading, showed the lowest (0.53). STN ECT was higher than IMPROVE ECT, in contrast to results from aerosol samples. A higher peak inert-mode temperature and extended heating times can elevate ECT/ECR ratios for pretreated geological samples by promoting pyrolyzed organic carbon (PyOC) removal over EC under trace levels of oxygen. Considering that PyOC within filter increases ECR while decreases ECT from the actual EC levels, simultaneous ECR and ECT measurements would constrain the range of EC loading and provide information on method performance. Further testing with standard reference materials of common environmental matrices supports the findings. Char and soot fractions of EC can be further separated using the IMPROVE protocol. The char/soot ratio was lower in street dusts (2.2 on average) than in soils (5.2 on average), most likely reflecting motor vehicle emissions. The soot concentrations agreed with EC from CTO-375, a pure thermal method. PMID:24358286

  12. Comparison of the Liaison® Calprotectin kit with a well established point of care test (Quantum Blue - Bühlmann-Alere®) in terms of analytical performances and ability to detect relapses amongst a Crohn population in follow-up.

    PubMed

    Delefortrie, Quentin; Schatt, Patricia; Grimmelprez, Alexandre; Gohy, Patrick; Deltour, Didier; Collard, Geneviève; Vankerkhoven, Patrick

    2016-02-01

    Although colonoscopy associated with histopathological sampling remains the gold standard in the diagnostic and follow-up of inflammatory bowel disease (IBD), calprotectin is becoming an essential biomarker in gastroenterology. The aim of this work is to compare a newly developed kit (Liaison® Calprotectin - Diasorin®) and its two distinct extraction protocols (weighing and extraction device protocol) with a well established point of care test (Quantum Blue® - Bühlmann-Alere®) in terms of analytical performances and ability to detect relapses amongst a Crohn's population in follow-up. Stool specimens were collected over a six month period and were composed of control and Crohn's patients. Amongst the Crohn's population disease activity (active vs quiescent) was evaluated by gastroenterologists. A significant difference was found between all three procedures in terms of calprotectin measurements (weighing protocol=30.3μg/g (median); stool extraction device protocol=36.9μg/g (median); Quantum Blue® (median)=63; Friedman test, P value=0.05). However, a good correlation was found between both extraction methods coupled with the Liaison® analyzer and between the Quantum Blue® (weighing protocol/extraction device protocol Rs=0.844, P=0.01; Quantum Blue®/extraction device protocol Rs=0.708, P=0.01; Quantum Blue®/weighing protocol, Rs=0.808, P=0.01). Finally, optimal cut-offs (and associated negative predictive values - NPV) for detecting relapses were in accordance with above results (Quantum Blue® 183.5μg/g and NPV of 100%>extraction device protocol+Liaison® analyzer 124.5μg/g and NPV of 93.5%>weighing protocol+Liaison® analyzer 106.5μg/g and NPV of 95%). Although all three methods correlated well and had relatively good NPV in terms of detecting relapses amongst a Crohn's population in follow-up, the lack of any international standard is the origin of different optimal cut-offs between the three procedures. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Capillary Electrophoresis Analysis of Organic Amines and Amino Acids in Saline and Acidic Samples Using the Mars Organic Analyzer

    NASA Astrophysics Data System (ADS)

    Stockton, Amanda M.; Chiesl, Thomas N.; Lowenstein, Tim K.; Amashukeli, Xenia; Grunthaner, Frank; Mathies, Richard A.

    2009-11-01

    The Mars Organic Analyzer (MOA) has enabled the sensitive detection of amino acid and amine biomarkers in laboratory standards and in a variety of field sample tests. However, the MOA is challenged when samples are extremely acidic and saline or contain polyvalent cations. Here, we have optimized the MOA analysis, sample labeling, and sample dilution buffers to handle such challenging samples more robustly. Higher ionic strength buffer systems with pKa values near pH 9 were developed to provide better buffering capacity and salt tolerance. The addition of ethylaminediaminetetraacetic acid (EDTA) ameliorates the negative effects of multivalent cations. The optimized protocol utilizes a 75 mM borate buffer (pH 9.5) for Pacific Blue labeling of amines and amino acids. After labeling, 50 mM (final concentration) EDTA is added to samples containing divalent cations to ameliorate their effects. This optimized protocol was used to successfully analyze amino acids in a saturated brine sample from Saline Valley, California, and a subcritical water extract of a highly acidic sample from the Río Tinto, Spain. This work expands the analytical capabilities of the MOA and increases its sensitivity and robustness for samples from extraterrestrial environments that may exhibit pH and salt extremes as well as metal ions.

  14. Capillary electrophoresis analysis of organic amines and amino acids in saline and acidic samples using the Mars organic analyzer.

    PubMed

    Stockton, Amanda M; Chiesl, Thomas N; Lowenstein, Tim K; Amashukeli, Xenia; Grunthaner, Frank; Mathies, Richard A

    2009-11-01

    The Mars Organic Analyzer (MOA) has enabled the sensitive detection of amino acid and amine biomarkers in laboratory standards and in a variety of field sample tests. However, the MOA is challenged when samples are extremely acidic and saline or contain polyvalent cations. Here, we have optimized the MOA analysis, sample labeling, and sample dilution buffers to handle such challenging samples more robustly. Higher ionic strength buffer systems with pK(a) values near pH 9 were developed to provide better buffering capacity and salt tolerance. The addition of ethylaminediaminetetraacetic acid (EDTA) ameliorates the negative effects of multivalent cations. The optimized protocol utilizes a 75 mM borate buffer (pH 9.5) for Pacific Blue labeling of amines and amino acids. After labeling, 50 mM (final concentration) EDTA is added to samples containing divalent cations to ameliorate their effects. This optimized protocol was used to successfully analyze amino acids in a saturated brine sample from Saline Valley, California, and a subcritical water extract of a highly acidic sample from the Río Tinto, Spain. This work expands the analytical capabilities of the MOA and increases its sensitivity and robustness for samples from extraterrestrial environments that may exhibit pH and salt extremes as well as metal ions.

  15. Optimization of analytical and pre-analytical conditions for MALDI-TOF-MS human urine protein profiles.

    PubMed

    Calvano, C D; Aresta, A; Iacovone, M; De Benedetto, G E; Zambonin, C G; Battaglia, M; Ditonno, P; Rutigliano, M; Bettocchi, C

    2010-03-11

    Protein analysis in biological fluids, such as urine, by means of mass spectrometry (MS) still suffers for insufficient standardization in protocols for sample collection, storage and preparation. In this work, the influence of these variables on healthy donors human urine protein profiling performed by matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was studied. A screening of various urine sample pre-treatment procedures and different sample deposition approaches on the MALDI target was performed. The influence of urine samples storage time and temperature on spectral profiles was evaluated by means of principal component analysis (PCA). The whole optimized procedure was eventually applied to the MALDI-TOF-MS analysis of human urine samples taken from prostate cancer patients. The best results in terms of detected ions number and abundance in the MS spectra were obtained by using home-made microcolumns packed with hydrophilic-lipophilic balance (HLB) resin as sample pre-treatment method; this procedure was also less expensive and suitable for high throughput analyses. Afterwards, the spin coating approach for sample deposition on the MALDI target plate was optimized, obtaining homogenous and reproducible spots. Then, PCA indicated that low storage temperatures of acidified and centrifuged samples, together with short handling time, allowed to obtain reproducible profiles without artifacts contribution due to experimental conditions. Finally, interesting differences were found by comparing the MALDI-TOF-MS protein profiles of pooled urine samples of healthy donors and prostate cancer patients. The results showed that analytical and pre-analytical variables are crucial for the success of urine analysis, to obtain meaningful and reproducible data, even if the intra-patient variability is very difficult to avoid. It has been proven how pooled urine samples can be an interesting way to make easier the comparison between healthy and pathological samples and to individuate possible differences in the protein expression between the two sets of samples. Copyright 2009 Elsevier B.V. All rights reserved.

  16. Establishment of Protocols for Global Metabolomics by LC-MS for Biomarker Discovery.

    PubMed

    Saigusa, Daisuke; Okamura, Yasunobu; Motoike, Ikuko N; Katoh, Yasutake; Kurosawa, Yasuhiro; Saijyo, Reina; Koshiba, Seizo; Yasuda, Jun; Motohashi, Hozumi; Sugawara, Junichi; Tanabe, Osamu; Kinoshita, Kengo; Yamamoto, Masayuki

    2016-01-01

    Metabolomics is a promising avenue for biomarker discovery. Although the quality of metabolomic analyses, especially global metabolomics (G-Met) using mass spectrometry (MS), largely depends on the instrumentation, potential bottlenecks still exist at several basic levels in the metabolomics workflow. Therefore, we established a precise protocol initially for the G-Met analyses of human blood plasma to overcome some these difficulties. In our protocol, samples are deproteinized in a 96-well plate using an automated liquid-handling system, and conducted either using a UHPLC-QTOF/MS system equipped with a reverse phase column or a LC-FTMS system equipped with a normal phase column. A normalization protocol of G-Met data was also developed to compensate for intra- and inter-batch differences, and the variations were significantly reduced along with our normalization, especially for the UHPLC-QTOF/MS data with a C18 reverse-phase column for positive ions. Secondly, we examined the changes in metabolomic profiles caused by the storage of EDTA-blood specimens to identify quality markers for the evaluation of the specimens' pre-analytical conditions. Forty quality markers, including lysophospholipids, dipeptides, fatty acids, succinic acid, amino acids, glucose, and uric acid were identified by G-Met for the evaluation of plasma sample quality and established the equation of calculating the quality score. We applied our quality markers to a small-scale study to evaluate the quality of clinical samples. The G-Met protocols and quality markers established here should prove useful for the discovery and development of biomarkers for a wider range of diseases.

  17. Discrimination of almonds (Prunus dulcis) geographical origin by minerals and fatty acids profiling.

    PubMed

    Amorello, Diana; Orecchio, Santino; Pace, Andrea; Barreca, Salvatore

    2016-09-01

    Twenty-one almond samples from three different geographical origins (Sicily, Spain and California) were investigated by determining minerals and fatty acids compositions. Data were used to discriminate by chemometry almond origin by linear discriminant analysis. With respect to previous PCA profiling studies, this work provides a simpler analytical protocol for the identification of almonds geographical origin. Classification by using mineral contents data only was correct in 77% of the samples, while, by using fatty acid profiles, the percentages of samples correctly classified reached 82%. The coupling of mineral contents and fatty acid profiles lead to an increased efficiency of the classification with 87% of samples correctly classified.

  18. Automated Sample Preparation for Radiogenic and Non-Traditional Metal Isotopes: Removing an Analytical Barrier for High Sample Throughput

    NASA Astrophysics Data System (ADS)

    Field, M. Paul; Romaniello, Stephen; Gordon, Gwyneth W.; Anbar, Ariel D.; Herrmann, Achim; Martinez-Boti, Miguel A.; Anagnostou, Eleni; Foster, Gavin L.

    2014-05-01

    MC-ICP-MS has dramatically improved the analytical throughput for high-precision radiogenic and non-traditional isotope ratio measurements, compared to TIMS. The generation of large data sets, however, remains hampered by tedious manual drip chromatography required for sample purification. A new, automated chromatography system reduces the laboratory bottle neck and expands the utility of high-precision isotope analyses in applications where large data sets are required: geochemistry, forensic anthropology, nuclear forensics, medical research and food authentication. We have developed protocols to automate ion exchange purification for several isotopic systems (B, Ca, Fe, Cu, Zn, Sr, Cd, Pb and U) using the new prepFAST-MC™ (ESI, Nebraska, Omaha). The system is not only inert (all-flouropolymer flow paths), but is also very flexible and can easily facilitate different resins, samples, and reagent types. When programmed, precise and accurate user defined volumes and flow rates are implemented to automatically load samples, wash the column, condition the column and elute fractions. Unattended, the automated, low-pressure ion exchange chromatography system can process up to 60 samples overnight. Excellent reproducibility, reliability, recovery, with low blank and carry over for samples in a variety of different matrices, have been demonstrated to give accurate and precise isotopic ratios within analytical error for several isotopic systems (B, Ca, Fe, Cu, Zn, Sr, Cd, Pb and U). This illustrates the potential of the new prepFAST-MC™ (ESI, Nebraska, Omaha) as a powerful tool in radiogenic and non-traditional isotope research.

  19. IFSA: a microfluidic chip-platform for frit-based immunoassay protocols

    NASA Astrophysics Data System (ADS)

    Hlawatsch, Nadine; Bangert, Michael; Miethe, Peter; Becker, Holger; Gärtner, Claudia

    2013-03-01

    Point-of-care diagnostics (POC) is one of the key application fields for lab-on-a-chip devices. While in recent years much of the work has concentrated on integrating complex molecular diagnostic assays onto a microfluidic device, there is a need to also put comparatively simple immunoassay-type protocols on a microfluidic platform. In this paper, we present the development of a microfluidic cartridge using an immunofiltration approach. In this method, the sandwich immunoassay takes place in a porous frit on which the antibodies have immobilized. The device is designed to be able to handle three samples in parallel and up to four analytical targets per sample. In order to meet the critical cost targets for the diagnostic market, the microfluidic chip has been designed and manufactured using high-volume manufacturing technologies in mind. Validation experiments show comparable sensitivities in comparison with conventional immunofiltration kits.

  20. USDA's National Food and Nutrient Analysis Program (NFNAP) produces high-quality data for USDA food composition databases: Two decades of collaboration.

    PubMed

    Haytowitz, David B; Pehrsson, Pamela R

    2018-01-01

    For nearly 20years, the National Food and Nutrient Analysis Program (NFNAP) has expanded and improved the quantity and quality of data in US Department of Agriculture's (USDA) food composition databases (FCDB) through the collection and analysis of nationally representative food samples. NFNAP employs statistically valid sampling plans, the Key Foods approach to identify and prioritize foods and nutrients, comprehensive quality control protocols, and analytical oversight to generate new and updated analytical data for food components. NFNAP has allowed the Nutrient Data Laboratory to keep up with the dynamic US food supply and emerging scientific research. Recently generated results for nationally representative food samples show marked changes compared to previous database values for selected nutrients. Monitoring changes in the composition of foods is critical in keeping FCDB up-to-date, so that they remain a vital tool in assessing the nutrient intake of national populations, as well as for providing dietary advice. Published by Elsevier Ltd.

  1. Screening apatites for (U-Th)/He thermochronometry via continuous ramped heating: He age components and implications for age dispersion

    NASA Astrophysics Data System (ADS)

    McDannell, Kalin T.; Zeitler, Peter K.; Janes, Darwin G.; Idleman, Bruce D.; Fayon, Annia K.

    2018-02-01

    Old slowly-cooled apatites often yield dispersed (U-Th)/He ages for a variety of reasons, some well understood and some not. Analytical protocols like careful grain selection can reduce the impact of this dispersion but add costs in time and resources and too often have proven insufficient. We assess a new analytical protocol that utilizes static-gas measurement during continuous ramped heating (CRH) as a means to rapidly screen apatite samples. In about the time required for a conventional total-gas analysis, this method can discriminate between samples showing expected volume-diffusion behavior and those showing anomalous release patterns inconsistent with their direct use in thermochronologic applications. This method also appears able to discriminate between the radiogenic and extraneous 4He fractions released by a sample, potentially allowing ages to be corrected. Well-behaved examples such as the Durango standard and other apatites with good age reproducibility show the expected smooth, sigmoidal gas-release curves predicted for volume diffusion using typical apatite kinetics, with complete exhaustion by ∼900 °C for linear heating at 20 °C/min. Secondary factors such as U and Th zoning and alpha-loss distribution have a relatively minor impact on such profiles. In contrast, samples having greater age dispersion show significant He release in the form of outgassing spikes and He release deferred to higher temperatures. Screening results for a range of samples permit us to assess the degree to which CRH screening can identify misbehaving grains, give insight into the source of extraneous He, and suggest that in some cases it may be possible to correct ages for the presence of such components.

  2. External evaluation of the Dimension Vista 1500® intelligent lab system.

    PubMed

    Bruneel, Arnaud; Dehoux, Monique; Barnier, Anne; Boutten, Anne

    2012-09-01

    Dimension Vista® analyzer combines four technologies (photometry, nephelometry, V-LYTE® integrated multisensor potentiometry, and LOCI® chemiluminescence) into one high-throughput system. We assessed analytical performance of assays routinely performed in our emergency laboratory according to the VALTEC protocol, and practicability. Precision was good for most parameters. Analytical domain was large and suitable for undiluted analysis in most clinical settings encountered in our hospital. Data were comparable and correlated to our routine analyzers (Roche Modular DP®, Abbott AXSYM®, Siemens Dimension® RxL, and BN ProSpec®). Performance of nephelometric and LOCI modules was excellent. Functional sensitivity of high-sensitivity C-reactive protein and cardiac troponin I were 0.165 mg/l and 0.03 ng/ml, respectively (coefficient of variation; CV < 10%). The influence of interfering substances (i.e., hemoglobin, bilirubin, or lipids) was moderate, and Dimension Vista® specifically alerted for interference according to HIL (hemolysis, icterus, lipemia) indices. Good instrument performance and full functionality (no reagent or sample carryover in the conditions evaluated, effective sample-volume detection, and clot detection) were confirmed. Simulated routine testing demonstrated excellent practicability, throughput, ease of use of software and security. Performance and practicability of Dimension Vista® are highly suitable for both routine and emergency use. Since no volume detection and thus no warning is available on limited sample racks, pediatric samples require special caution to the Siemens protocol to be analyzed in secured conditions. Our experience in routine practice is also discussed, i.e., the impact of daily workload, "manual" steps resulting from dilutions and pediatric samples, maintenances, flex hydration on instrument's performance on throughput and turnaround time. © 2012 Wiley Periodicals, Inc.

  3. [Pre-analytical stage for biomarker assessment in breast cancer: 2014 update of the GEFPICS' guidelines in France].

    PubMed

    MacGrogan, Gaëtan; Mathieu, Marie-Christine; Poulet, Bruno; Penault-Llorca, Frédérique; Vincent-Salomon, Anne; Roger, Pascal; Treilleux, Isabelle; Valent, Alexander; Antoine, Martine; Becette, Véronique; Bor, Catherine; Brabencova, Eva; Charafe-Jauffret, Emmanuelle; Chenard, Marie-Pierre; Dauplat, Marie-Mélanie; Delrée, Paul; Devouassoux, Mojgan; Fiche, Maryse; Fondrevelle, Marie-Eve; Fridman, Viviana; Garbar, Christian; Genin, Pascal; Ghnassia, Jean-Pierre; Haudebourg, Juliette; Laberge-Le Couteulx, Sophie; Loussouarn, Delphine; Maran-Gonzalez, Aurélie; Marcy, Myriam; Michenet, Patrick; Sagan, Christine; Trassard, Martine; Verriele, Véronique; Arnould, Laurent; Lacroix-Triki, Magali

    2014-10-01

    Biomarker assessment of breast cancer tumor samples is part of the routine workflow of pathology laboratories. International guidelines have recently been updated, with special regards to the pre-analytical steps that are critical for the quality of immunohistochemical and in situ hybridization procedures, whatever the biomarker analyzed. Fixation and specimen handling protocols must be standardized, validated and carefully tracked. Cooperation and training of the personnel involved in the specimen workflow (e.g. radiologists, surgeons, nurses, technicians and pathologists) are of paramount importance. The GEFPICS' update of the recommendations herein details and comments the different steps of the pre-analytical process. Application of these guidelines and participation to quality insurance programs are mandatory to ensure the correct evaluation of oncotheranostic biomarkers. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  4. Investigation of preparation techniques for δ2H analysis of keratin materials and a proposed analytical protocol

    USGS Publications Warehouse

    Qi, H.; Coplen, T.B.

    2011-01-01

    Accurate hydrogen isotopic measurements of keratin materials have been a challenge due to exchangeable hydrogen in the sample matrix and the paucity of appropriate isotopic reference materials for calibration. We found that the most reproducible δ2HVSMOW-SLAP and mole fraction of exchangeable hydrogen, x(H)ex, of keratin materials were measured with equilibration at ambient temperature using two desiccators and two different equilibration waters with two sets of the keratin materials for 6 days. Following equilibration, drying the keratin materials in a vacuum oven for 4 days at 60 °C was most critical. The δ2H analysis protocol also includes interspersing isotopic reference waters in silver tubes among samples in the carousel of a thermal conversion elemental analyzer (TC/EA) reduction unit. Using this analytical protocol, δ2HVSMOW-SLAP values of the non-exchangeable fractions of USGS42 and USGS43 human-hair isotopic reference materials were determined to be –78.5 ± 2.3 ‰ and –50.3 ± 2.8 ‰, respectively. The measured x(H)ex values of keratin materials analyzed with steam equilibration and N2 drying were substantially higher than those previously published, and dry N2 purging was unable to remove absorbed moisture completely, even with overnight purging. The δ2H values of keratin materials measured with steam equilibration were about 10 ‰ lower than values determined with equilibration in desiccators at ambient temperatures when on-line evacuation was used to dry samples. With steam equilibrations the x(H)ex of commercial keratin powder was as high as 28 %. Using human-hair isotopic reference materials to calibrate other keratin materials, such as hoof or horn, can introduce bias in δ2H measurements because the amount of absorbed water and the x(H)ex values may differ from those of unknown samples. Correct δ2HVSMOW-SLAP values of the non-exchangeable fractions of unknown human-hair samples can be determined with atmospheric moisture equilibration by normalizing with USGS42 and USGS43 human-hair reference materials when all materials have the same powder size.

  5. Evaluation of analytical performance of a new high-sensitivity immunoassay for cardiac troponin I.

    PubMed

    Masotti, Silvia; Prontera, Concetta; Musetti, Veronica; Storti, Simona; Ndreu, Rudina; Zucchelli, Gian Carlo; Passino, Claudio; Clerico, Aldo

    2018-02-23

    The study aim was to evaluate and compare the analytical performance of the new chemiluminescent immunoassay for cardiac troponin I (cTnI), called Access hs-TnI using DxI platform, with those of Access AccuTnI+3 method, and high-sensitivity (hs) cTnI method for ARCHITECT platform. The limits of blank (LoB), detection (LoD) and quantitation (LoQ) at 10% and 20% CV were evaluated according to international standardized protocols. For the evaluation of analytical performance and comparison of cTnI results, both heparinized plasma samples, collected from healthy subjects and patients with cardiac diseases, and quality control samples distributed in external quality assessment programs were used. LoB, LoD and LoQ at 20% and 10% CV values of the Access hs-cTnI method were 0.6, 1.3, 2.1 and 5.3 ng/L, respectively. Access hs-cTnI method showed analytical performance significantly better than that of Access AccuTnI+3 method and similar results to those of hs ARCHITECT cTnI method. Moreover, the cTnI concentrations measured with Access hs-cTnI method showed close linear regressions with both Access AccuTnI+3 and ARCHITECT hs-cTnI methods, although there were systematic differences between these methods. There was no difference between cTnI values measured by Access hs-cTnI in heparinized plasma and serum samples, whereas there was a significant difference between cTnI values, respectively measured in EDTA and heparin plasma samples. Access hs-cTnI has analytical sensitivity parameters significantly improved compared to Access AccuTnI+3 method and is similar to those of the high-sensitivity method using ARCHITECT platform.

  6. Mainstream Smoke Levels of Volatile Organic Compounds in 50 U.S. Domestic Cigarette Brands Smoked With the ISO and Canadian Intense Protocols.

    PubMed

    Pazo, Daniel Y; Moliere, Fallon; Sampson, Maureen M; Reese, Christopher M; Agnew-Heard, Kimberly A; Walters, Matthew J; Holman, Matthew R; Blount, Benjamin C; Watson, Clifford H; Chambers, David M

    2016-09-01

    A significant portion of the increased risk of cancer and respiratory disease from exposure to cigarette smoke is attributed to volatile organic compounds (VOCs). In this study, 21 VOCs were quantified in mainstream cigarette smoke from 50U.S. domestic brand varieties that included high market share brands and 2 Kentucky research cigarettes (3R4F and 1R5F). Mainstream smoke was generated under ISO 3308 and Canadian Intense (CI) smoking protocols with linear smoking machines with a gas sampling bag collection followed by solid phase microextraction/gas chromatography/mass spectrometry (SPME/GC/MS) analysis. For both protocols, mainstream smoke VOC amounts among the different brand varieties were strongly correlated between the majority of the analytes. Overall, Pearson correlation (r) ranged from 0.68 to 0.99 for ISO and 0.36 to 0.95 for CI. However, monoaromatic compounds were found to increase disproportionately compared to unsaturated, nitro, and carbonyl compounds under the CI smoking protocol where filter ventilation is blocked. Overall, machine generated "vapor phase" amounts (µg/cigarette) are primarily attributed to smoking protocol (e.g., blocking of vent holes, puff volume, and puff duration) and filter ventilation. A possible cause for the disproportionate increase in monoaromatic compounds could be increased pyrolysis under low oxygen conditions associated with the CI protocol. This is the most comprehensive assessment of volatile organic compounds (VOCs) in cigarette smoke to date, encompassing 21 toxic VOCs, 50 different cigarette brand varieties, and 2 different machine smoking protocols (ISO and CI). For most analytes relative proportions remain consistent among U.S. cigarette brand varieties regardless of smoking protocol, however the CI smoking protocol did cause up to a factor of 6 increase in the proportion of monoaromatic compounds. This study serves as a basis to assess VOC exposure as cigarette smoke is a principle source of overall population-level VOC exposure in the United States. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  7. Target analyte quantification by isotope dilution LC-MS/MS directly referring to internal standard concentrations--validation for serum cortisol measurement.

    PubMed

    Maier, Barbara; Vogeser, Michael

    2013-04-01

    Isotope dilution LC-MS/MS methods used in the clinical laboratory typically involve multi-point external calibration in each analytical series. Our aim was to test the hypothesis that determination of target analyte concentrations directly derived from the relation of the target analyte peak area to the peak area of a corresponding stable isotope labelled internal standard compound [direct isotope dilution analysis (DIDA)] may be not inferior to conventional external calibration with respect to accuracy and reproducibility. Quality control samples and human serum pools were analysed in a comparative validation protocol for cortisol as an exemplary analyte by LC-MS/MS. Accuracy and reproducibility were compared between quantification either involving a six-point external calibration function, or a result calculation merely based on peak area ratios of unlabelled and labelled analyte. Both quantification approaches resulted in similar accuracy and reproducibility. For specified analytes, reliable analyte quantification directly derived from the ratio of peak areas of labelled and unlabelled analyte without the need for a time consuming multi-point calibration series is possible. This DIDA approach is of considerable practical importance for the application of LC-MS/MS in the clinical laboratory where short turnaround times often have high priority.

  8. Development of analytical methods for multiplex bio-assay with inductively coupled plasma mass spectrometry.

    PubMed

    Ornatsky, Olga I; Kinach, Robert; Bandura, Dmitry R; Lou, Xudong; Tanner, Scott D; Baranov, Vladimir I; Nitz, Mark; Winnik, Mitchell A

    2008-01-01

    Advances in the development of highly multiplexed bio-analytical assays with inductively coupled plasma mass spectrometry (ICP-MS) detection are discussed. Use of novel reagents specifically designed for immunological methods utilizing elemental analysis is presented. The major steps of method development, including selection of elements for tags, validation of tagged reagents, and examples of multiplexed assays, are considered in detail. The paper further describes experimental protocols for elemental tagging of antibodies, immunostaining of live and fixed human leukemia cells, and preparation of samples for ICP-MS analysis. Quantitative analysis of surface antigens on model cell lines using a cocktail of seven lanthanide labeled antibodies demonstrated high specificity and concordance with conventional immunophenotyping.

  9. Chemical and biological threat-agent detection using electrophoresis-based lab-on-a-chip devices.

    PubMed

    Borowsky, Joseph; Collins, Greg E

    2007-10-01

    The ability to separate complex mixtures of analytes has made capillary electrophoresis (CE) a powerful analytical tool since its modern configuration was first introduced over 25 years ago. The technique found new utility with its application to the microfluidics based lab-on-a-chip platform (i.e., microchip), which resulted in ever smaller footprints, sample volumes, and analysis times. These features, coupled with the technique's potential for portability, have prompted recent interest in the development of novel analyzers for chemical and biological threat agents. This article will comment on three main areas of microchip CE as applied to the separation and detection of threat agents: detection techniques and their corresponding limits of detection, sampling protocol and preparation time, and system portability. These three areas typify the broad utility of lab-on-a-chip for meeting critical, present-day security, in addition to illustrating areas wherein advances are necessary.

  10. Detection of Salmonella enterica Serovar Typhimurium by Using a Rapid, Array-Based Immunosensor

    PubMed Central

    Taitt, Chris Rowe; Shubin, Yura S.; Angel, Roselina; Ligler, Frances S.

    2004-01-01

    The multianalyte array biosensor (MAAB) is a rapid analysis instrument capable of detecting multiple analytes simultaneously. Rapid (15-min), single-analyte sandwich immunoassays were developed for the detection of Salmonella enterica serovar Typhimurium, with a detection limit of 8 × 104 CFU/ml; the limit of detection was improved 10-fold by lengthening the assay protocol to 1 h. S. enterica serovar Typhimurium was also detected in the following spiked foodstuffs, with minimal sample preparation: sausage, cantaloupe, whole liquid egg, alfalfa sprouts, and chicken carcass rinse. Cross-reactivity tests were performed with Escherichia coli and Campylobacter jejuni. To determine whether the MAAB has potential as a screening tool for the diagnosis of asymptomatic Salmonella infection of poultry, chicken excretal samples from a private, noncommercial farm and from university poultry facilities were tested. While the private farm excreta gave rise to signals significantly above the buffer blanks, none of the university samples tested positive for S. enterica serovar Typhimurium without spiking; dose-response curves of spiked excretal samples from university-raised poultry gave limits of detection of 8 × 103 CFU/g. PMID:14711637

  11. Development of an analytical microbial consortia method for enhancing performance monitoring at aerobic wastewater treatment plants.

    PubMed

    Razban, Behrooz; Nelson, Kristina Y; McMartin, Dena W; Cullimore, D Roy; Wall, Michelle; Wang, Dunling

    2012-01-01

    An analytical method to produce profiles of bacterial biomass fatty acid methyl esters (FAME) was developed employing rapid agitation followed by static incubation (RASI) using selective media of wastewater microbial communities. The results were compiled to produce a unique library for comparison and performance analysis at a Wastewater Treatment Plant (WWTP). A total of 146 samples from the aerated WWTP, comprising 73 samples of each secondary and tertiary effluent, were included analyzed. For comparison purposes, all samples were evaluated via a similarity index (SI) with secondary effluents producing an SI of 0.88 with 2.7% variation and tertiary samples producing an SI 0.86 with 5.0% variation. The results also highlighted significant differences between the fatty acid profiles of the tertiary and secondary effluents indicating considerable shifts in the bacterial community profile between these treatment phases. The WWTP performance results using this method were highly replicable and reproducible indicating that the protocol has potential as a performance-monitoring tool for aerated WWTPs. The results quickly and accurately reflect shifts in dominant bacterial communities that result when processes operations and performance change.

  12. Automation of sample preparation for mass cytometry barcoding in support of clinical research: protocol optimization.

    PubMed

    Nassar, Ala F; Wisnewski, Adam V; Raddassi, Khadir

    2017-03-01

    Analysis of multiplexed assays is highly important for clinical diagnostics and other analytical applications. Mass cytometry enables multi-dimensional, single-cell analysis of cell type and state. In mass cytometry, the rare earth metals used as reporters on antibodies allow determination of marker expression in individual cells. Barcode-based bioassays for CyTOF are able to encode and decode for different experimental conditions or samples within the same experiment, facilitating progress in producing straightforward and consistent results. Herein, an integrated protocol for automated sample preparation for barcoding used in conjunction with mass cytometry for clinical bioanalysis samples is described; we offer results of our work with barcoding protocol optimization. In addition, we present some points to be considered in order to minimize the variability of quantitative mass cytometry measurements. For example, we discuss the importance of having multiple populations during titration of the antibodies and effect of storage and shipping of labelled samples on the stability of staining for purposes of CyTOF analysis. Data quality is not affected when labelled samples are stored either frozen or at 4 °C and used within 10 days; we observed that cell loss is greater if cells are washed with deionized water prior to shipment or are shipped in lower concentration. Once the labelled samples for CyTOF are suspended in deionized water, the analysis should be performed expeditiously, preferably within the first hour. Damage can be minimized if the cells are resuspended in phosphate-buffered saline (PBS) rather than deionized water while waiting for data acquisition.

  13. Seabird tissue archival and monitoring project: Protocol for collecting and banking seabird eggs

    USGS Publications Warehouse

    Weston-York, Geoff; Porter, Barbara J.; Pugh, Rebecca S.; Roseneau, David G.; Simac, Kristin S.; Becker, Paul R.; Thorsteinson, Lyman K.; Wise, Stephen A.

    2001-01-01

    Archiving biological and environmental samples for retrospective analysis is a major component of systematic environmental monitoring. The long-term storage of carefully selected, representative samples in an environmental specimen bank is an important complement to the real-time monitoring of the environment. These archived samples permit:The use of subsequently developed innovative analytical technology that was not available at the time the samples were archived, for clear state-of-art identification an~ quantification of analytes of interest,The identification and quantification of analytes that are of subsequent interest but that were not of interest at the time the samples were archived, andThe comparison of present and past analytical techniques and values, providing continued credibility of past analytical values, and allowing flexibility in environmental monitoring programs.Seabirds, including albatrosses, pelicans, cormorants, terns, kittiwakes, murres, guillemots, and puffins spend most of their lives at sea and have special adaptations for feeding in the marine environment, including the ability to excrete the excess salt obtained from ingesting seawater. Many species nest in dense groups (colonies) on steep, precipitous sea-cliffs and headlands.Seabirds are long-lived and slow to mature. They occupy high positions in the marine food web and are considered sensitive indicators for the marine environment (prey includes krill, small fish, and squid). Breeding success, timing of nesting, diets, and survival rates may provide early indications of changing environmental conditions (e.g., see Hatch et aI., 1993). Chemical analysis of seabird tissues, including egg contents, can be particularly useful in determining whether contaminants (and potential biological effects) associated with human industrial activities, such as offshore petroleum and mineral exploration and development, are accumulating in marine environments. The collection and archival of seabird tissues over a period of several years will be a resource for future analyses, providing samples that can be used to determine historical baseline contaminant levels.

  14. Comparison of precipitation chemistry measurements obtained by the Canadian Air and Precipitation Monitoring Network and National Atmospheric Deposition Program for the period 1995-2004

    USGS Publications Warehouse

    Wetherbee, Gregory A.; Shaw, Michael J.; Latysh, Natalie E.; Lehmann, Christopher M.B.; Rothert, Jane E.

    2010-01-01

    Precipitation chemistry and depth measurements obtained by the Canadian Air and Precipitation Monitoring Network (CAPMoN) and the US National Atmospheric Deposition Program/National Trends Network (NADP/NTN) were compared for the 10-year period 1995–2004. Colocated sets of CAPMoN and NADP instrumentation, consisting of precipitation collectors and rain gages, were operated simultaneously per standard protocols for each network at Sutton, Ontario and Frelighsburg, Ontario, Canada and at State College, PA, USA. CAPMoN samples were collected daily, and NADP samples were collected weekly, and samples were analyzed exclusively by each network’s laboratory for pH, H + , Ca2+  , Mg2+  , Na + , K + , NH+4 , Cl − , NO−3 , and SO2−4 . Weekly and annual precipitation-weighted mean concentrations for each network were compared. This study is a follow-up to an earlier internetwork comparison for the period 1986–1993, published by Alain Sirois, Robert Vet, and Dennis Lamb in 2000. Median weekly internetwork differences for 1995–2004 data were the same to slightly lower than for data for the previous study period (1986–1993) for all analytes except NO−3 , SO2−4 , and sample depth. A 1994 NADP sampling protocol change and a 1998 change in the types of filters used to process NADP samples reversed the previously identified negative bias in NADP data for hydrogen-ion and sodium concentrations. Statistically significant biases (α = 0.10) for sodium and hydrogen-ion concentrations observed in the 1986–1993 data were not significant for 1995–2004. Weekly CAPMoN measurements generally are higher than weekly NADP measurements due to differences in sample filtration and field instrumentation, not sample evaporation, contamination, or analytical laboratory differences.

  15. SYTO probes: markers of apoptotic cell demise.

    PubMed

    Wlodkowic, Donald; Skommer, Joanna

    2007-10-01

    As mechanistic studies on tumor cell death advance towards their ultimate translational goal, there is a need for specific, rapid, and high-throughput analytical tools to detect diverse cell demise modes. Patented DNA-binding SYTO probes, for example, are gaining increasing interest as easy-to-use markers of caspase-dependent apoptotic cell death. They are proving convenient for tracking apoptosis in diverse hematopoietic cell lines and primary tumor samples, and, due to their spectral characteristics, appear to be useful for the development of multiparameter flow cytometry assays. Herein, several protocols for multiparametric assessment of apoptotic events using SYTO probes are provided. There are protocols describing the use of green fluorescent SYTO 16 and red fluorescent SYTO 17 dyes in combination with plasma membrane permeability markers. Another protocol highlights the multiparametric use of SYTO 16 dye in conjunction with the mitochondrial membrane potential sensitive probe, tetramethylrhodamine methyl ester (TMRM), and the plasma membrane permeability marker, 7-aminoactinomycin D (7-AAD).

  16. Simultaneous, untargeted metabolic profiling of polar and nonpolar metabolites by LC-Q-TOF mass spectrometry.

    PubMed

    Kirkwood, Jay S; Maier, Claudia; Stevens, Jan F

    2013-05-01

    At its most ambitious, untargeted metabolomics aims to characterize and quantify all of the metabolites in a given system. Metabolites are often present at a broad range of concentrations and possess diverse physical properties complicating this task. Performing multiple sample extractions, concentrating sample extracts, and using several separation and detection methods are common strategies to overcome these challenges but require a great amount of resources. This protocol describes the untargeted, metabolic profiling of polar and nonpolar metabolites with a single extraction and using a single analytical platform. © 2013 by John Wiley & Sons, Inc.

  17. Evaluation of two methods to determine glyphosate and AMPA in soils of Argentina

    NASA Astrophysics Data System (ADS)

    De Geronimo, Eduardo; Lorenzon, Claudio; Iwasita, Barbara; Faggioli, Valeria; Aparicio, Virginia; Costa, Jose Luis

    2017-04-01

    Argentine agricultural production is fundamentally based on a technological package combining no-tillage and the dependence of glyphosate applications to control weeds in transgenic crops (soybean, maize and cotton). Therefore, glyphosate is the most employed herbicide in the country, where 180 to 200 million liters are applied every year. Due to its widespread use, it is important to assess its impact on the environment and, therefore, reliable analytical methods are mandatory. Glyphosate molecule exhibits unique physical and chemical characteristics which difficult its quantification, especially in soils with high organic matter content, such as the central eastern Argentine soils, where strong interferences are normally observed. The objective of this work was to compare two methods for extraction and quantification of glyphosate and AMPA in samples of 8 representative soils of Argentina. The first analytical method (method 1) was based on the use of phosphate buffer as extracting solution and dichloromethane to minimize matrix organic content. In the second method (method 2), potassium hydroxide was used to extract the analytes followed by a clean-up step using solid phase extraction (SPE) to minimize strong interferences. Sensitivity, recoveries, matrix effects and robustness were evaluated. Both methodologies involved a derivatization with 9-fluorenyl-methyl-chloroformate (FMOC) in borate buffer and detection based on ultra-high-pressure liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). Recoveries obtained from soil samples spiked at 0.1 and 1 mg kg-1 and were satisfactory in both methods (70% - 120%). However, there was a remarkable difference regarding the matrix effect, being the SPE clean-up step (method 2) insufficient to remove the interferences. Whereas the dilution and the clean-up with dichloromethane (method 1) were more effective minimizing the ionic suppression. Moreover, method 1 had fewer steps in the protocol of sample processing than method 2. This can be highly valuable in the routine lab work due to the reduction of potential undesired errors such as the loss of analyte or sample contamination. In addition, the substitution of SPE by another alternative involved a considerable reduction of analytical costs in method 1. We conclude that method 1 seemed to be simpler and cheaper than method 2, as well as reliable to quantify glyphosate in Argentinean soils. We hope that this experience can be useful to simplify the protocols of glyphosate quantification and contribute to the understanding of the fate of this herbicide in the environment.

  18. Analytical and pre-analytical performance characteristics of a novel cartridge-type blood gas analyzer for point-of-care and laboratory testing.

    PubMed

    Oyaert, Matthijs; Van Maerken, Tom; Bridts, Silke; Van Loon, Silvi; Laverge, Heleen; Stove, Veronique

    2018-03-01

    Point-of-care blood gas test results may benefit therapeutic decision making by their immediate impact on patient care. We evaluated the (pre-)analytical performance of a novel cartridge-type blood gas analyzer, the GEM Premier 5000 (Werfen), for the determination of pH, partial carbon dioxide pressure (pCO 2 ), partial oxygen pressure (pO 2 ), sodium (Na + ), potassium (K + ), chloride (Cl - ), ionized calcium ( i Ca 2+ ), glucose, lactate, and total hemoglobin (tHb). Total imprecision was estimated according to the CLSI EP5-A2 protocol. The estimated total error was calculated based on the mean of the range claimed by the manufacturer. Based on the CLSI EP9-A2 evaluation protocol, a method comparison with the Siemens RapidPoint 500 and Abbott i-STAT CG8+ was performed. Obtained data were compared against preset quality specifications. Interference of potential pre-analytical confounders on co-oximetry and electrolyte concentrations were studied. The analytical performance was acceptable for all parameters tested. Method comparison demonstrated good agreement to the RapidPoint 500 and i-STAT CG8+, except for some parameters (RapidPoint 500: pCO 2 , K + , lactate and tHb; i-STAT CG8+: pO 2 , Na + , i Ca 2+ and tHb) for which significant differences between analyzers were recorded. No interference of lipemia or methylene blue on CO-oximetry results was found. On the contrary, significant interference for benzalkonium and hemolysis on electrolyte measurements were found, for which the user is notified by an interferent specific flag. Identification of sample errors from pre-analytical sources, such as interferences and automatic corrective actions, along with the analytical performance, ease of use and low maintenance time of the instrument, makes the evaluated instrument a suitable blood gas analyzer for both POCT and laboratory use. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples.

    PubMed

    Gerace, E; Salomone, A; Abbadessa, G; Racca, S; Vincenti, M

    2012-02-01

    A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone) plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid-liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS) after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration.

  20. Rapid determination of anti-estrogens by gas chromatography/mass spectrometry in urine: Method validation and application to real samples

    PubMed Central

    Gerace, E.; Salomone, A.; Abbadessa, G.; Racca, S.; Vincenti, M.

    2011-01-01

    A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone) plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid–liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS) after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration. PMID:29403714

  1. Quality assurance and quality control of geochemical data—A primer for the research scientist

    USGS Publications Warehouse

    Geboy, Nicholas J.; Engle, Mark A.

    2011-01-01

    Geochemistry is a constantly expanding science. More and more, scientists are employing geochemical tools to help answer questions about the Earth and earth system processes. Scientists may assume that the responsibility of examining and assessing the quality of the geochemical data they generate is not theirs but rather that of the analytical laboratories to which their samples have been submitted. This assumption may be partially based on knowledge about internal and external quality assurance and quality control (QA/QC) programs in which analytical laboratories typically participate. Or there may be a perceived lack of time or resources to adequately examine data quality. Regardless of the reason, the lack of QA/QC protocols can lead to the generation and publication of erroneous data. Because the interpretations drawn from the data are primary products to U.S. Geological Survey (USGS) stakeholders, the consequences of publishing erroneous results can be significant. The principal investigator of a scientific study ultimately is responsible for the quality and interpretation of the project's findings, and thus must also play a role in the understanding, implementation, and presentation of QA/QC information about the data. Although occasionally ignored, QA/QC protocols apply not only to procedures in the laboratory but also in the initial planning of a research study and throughout the life of the project. Many of the tenets of developing a sound QA/QC program or protocols also parallel the core concepts of developing a good study: What is the main objective of the study? Will the methods selected provide data of enough resolution to answer the hypothesis? How should samples be collected? Are there known or unknown artifacts or contamination sources in the sampling and analysis methods? Assessing data quality requires communication between the scientists responsible for designing the study and those collecting samples, analyzing samples, treating data, and interpreting results. This primer has been developed to provide basic information and guidance about developing QA/QC protocols for geochemical studies. It is not intended to be a comprehensive guide but rather an introduction to key concepts tied to a list of relevant references for further reading. The guidelines are presented in stepwise order beginning with presampling considerations and continuing through final data interpretation. The goal of this primer is to outline basic QA/QC practices that scientists can use before, during, and after chemical analysis to ensure the validity of the data they collect with the goal of providing defendable results and conclusions.

  2. Geochemical data for Colorado soils-Results from the 2006 state-scale geochemical survey

    USGS Publications Warehouse

    Smith, David B.; Ellefsen, Karl J.; Kilburn, James E.

    2010-01-01

    In 2006, soil samples were collected at 960 sites (1 site per 280 square kilometers) throughout the state of Colorado. These samples were collected from a depth of 0-15 centimeters and, following a near-total multi-acid digestion, were analyzed for a suite of more than 40 major and trace elements. The resulting data set provides a baseline for the natural variation in soil geochemistry for Colorado and forms the basis for detecting changes in soil composition that might result from natural processes or anthropogenic activities. This report describes the sampling and analytical protocols used and makes available all the soil geochemical data generated in the study.

  3. Comparison of protocols and RNA carriers for plasma miRNA isolation. Unraveling RNA carrier influence on miRNA isolation

    PubMed Central

    Martos, Laura; Fernández-Pardo, Álvaro; Oto, Julia; Medina, Pilar; España, Francisco; Navarro, Silvia

    2017-01-01

    microRNAs are promising biomarkers in biological fluids in several diseases. Different plasma RNA isolation protocols and carriers are available, but their efficiencies have been scarcely compared. Plasma microRNAs were isolated using a phenol and column-based procedure and a column-based procedure, in the presence or absence of two RNA carriers (yeast RNA and MS2 RNA). We evaluated the presence of PCR inhibitors and the relative abundance of certain microRNAs by qRT-PCR. Furthermore, we analyzed the association between different isolation protocols, the relative abundance of the miRNAs in the sample, the GC content and the free energy of microRNAs. In all microRNAs analyzed, the addition of yeast RNA as a carrier in the different isolation protocols used gave lower raw Cq values, indicating higher microRNA recovery. Moreover, this increase in microRNAs recovery was dependent on their own relative abundance in the sample, their GC content and the free-energy of their own most stable secondary structure. Furthermore, the normalization of microRNA levels by an endogenous microRNA is more reliable than the normalization by plasma volume, as it reduced the difference in microRNA fold abundance between the different isolation protocols evaluated. Our thorough study indicates that a standardization of pre- and analytical conditions is necessary to obtain reproducible inter-laboratory results in plasma microRNA studies. PMID:29077772

  4. [Patient identification errors and biological samples in the analytical process: Is it possible to improve patient safety?].

    PubMed

    Cuadrado-Cenzual, M A; García Briñón, M; de Gracia Hills, Y; González Estecha, M; Collado Yurrita, L; de Pedro Moro, J A; Fernández Pérez, C; Arroyo Fernández, M

    2015-01-01

    Patient identification errors and biological samples are one of the problems with the highest risk factor in causing an adverse event in the patient. To detect and analyse the causes of patient identification errors in analytical requests (PIEAR) from emergency departments, and to develop improvement strategies. A process and protocol was designed, to be followed by all professionals involved in the requesting and performing of laboratory tests. Evaluation and monitoring indicators of PIEAR were determined, before and after the implementation of these improvement measures (years 2010-2014). A total of 316 PIEAR were detected in a total of 483,254 emergency service requests during the study period, representing a mean of 6.80/10,000 requests. Patient identification failure was the most frequent in all the 6-monthly periods assessed, with a significant difference (P<.0001). The improvement strategies applied showed to be effective in detecting PIEAR, as well as the prevention of such errors. However, we must continue working with this strategy, promoting a culture of safety for all the professionals involved, and trying to achieve the goal that 100% of the analytical and samples are properly identified. Copyright © 2015 SECA. Published by Elsevier Espana. All rights reserved.

  5. A large-scale superhydrophobic surface-enhanced Raman scattering (SERS) platform fabricated via capillary force lithography and assembly of Ag nanocubes for ultratrace molecular sensing.

    PubMed

    Tan, Joel Ming Rui; Ruan, Justina Jiexin; Lee, Hiang Kwee; Phang, In Yee; Ling, Xing Yi

    2014-12-28

    An analytical platform with an ultratrace detection limit in the atto-molar (aM) concentration range is vital for forensic, industrial and environmental sectors that handle scarce/highly toxic samples. Superhydrophobic surface-enhanced Raman scattering (SERS) platforms serve as ideal platforms to enhance detection sensitivity by reducing the random spreading of aqueous solution. However, the fabrication of superhydrophobic SERS platforms is generally limited due to the use of sophisticated and expensive protocols and/or suffers structural and signal inconsistency. Herein, we demonstrate a high-throughput fabrication of a stable and uniform superhydrophobic SERS platform for ultratrace molecular sensing. Large-area box-like micropatterns of the polymeric surface are first fabricated using capillary force lithography (CFL). Subsequently, plasmonic properties are incorporated into the patterned surfaces by decorating with Ag nanocubes using the Langmuir-Schaefer technique. To create a stable superhydrophobic SERS platform, an additional 25 nm Ag film is coated over the Ag nanocube-decorated patterned template followed by chemical functionalization with perfluorodecanethiol. Our resulting superhydrophobic SERS platform demonstrates excellent water-repellency with a static contact angle of 165° ± 9° and a consequent analyte concentration factor of 59-fold, as compared to its hydrophilic counterpart. By combining the analyte concentration effect of superhydrophobic surfaces with the intense electromagnetic "hot spots" of Ag nanocubes, our superhydrophobic SERS platform achieves an ultra-low detection limit of 10(-17) M (10 aM) for rhodamine 6G using just 4 μL of analyte solutions, corresponding to an analytical SERS enhancement factor of 10(13). Our fabrication protocol demonstrates a simple, cost- and time-effective approach for the large-scale fabrication of a superhydrophobic SERS platform for ultratrace molecular detection.

  6. Considerations in detecting CDC select agents under field conditions

    NASA Astrophysics Data System (ADS)

    Spinelli, Charles; Soelberg, Scott; Swanson, Nathaneal; Furlong, Clement; Baker, Paul

    2008-04-01

    Surface Plasmon Resonance (SPR) has become a widely accepted technique for real-time detection of interactions between receptor molecules and ligands. Antibody may serve as receptor and can be attached to the gold surface of the SPR device, while candidate analyte fluids contact the detecting antibody. Minute, but detectable, changes in refractive indices (RI) indicate that analyte has bound to the antibody. A decade ago, an inexpensive, robust, miniature and fully integrated SPR chip, called SPREETA, was developed. University of Washington (UW) researchers subsequently developed a portable, temperature-regulated instrument, called SPIRIT, to simultaneously use eight of these three-channel SPREETA chips. A SPIRIT prototype instrument was tested in the field, coupled to a remote reporting system on a surrogate unmanned aerial vehicle (UAV). Two target protein analytes were released sequentially as aerosols with low analyte concentration during each of three flights and were successfully detected and verified. Laboratory experimentation with a more advanced SPIRIT instrument demonstrated detection of very low levels of several select biological agents that might be employed by bioterrorists. Agent detection under field-like conditions is more challenging, especially as analyte concentrations are reduced and complex matricies are introduced. Two different sample preconditioning protocols have been developed for select agents in complex matrices. Use of these preconditioning techniques has allowed laboratory detection in spiked heavy mud of Francisella tularensis at 10 3 CFU/ml, Bacillus anthracis spores at 10 3 CFU/ml, Staphylococcal enterotoxin B (SEB) at 1 ng/ml, and Vaccinia virus (a smallpox simulant) at 10 5 PFU/ml. Ongoing experiments are aimed at simultaneous detection of multiple agents in spiked heavy mud, using a multiplex preconditioning protocol.

  7. Precise determination of triple Sr isotopes (δ⁸⁷Sr and δ⁸⁸Sr) using MC-ICP-MS.

    PubMed

    Liu, Hou-Chun; You, Chen-Feng; Huang, Kuo-Fang; Chung, Chuan-Hsiung

    2012-01-15

    The non-traditional stable strontium (Sr) isotopes have received increasing attention recently as new geochemical tracers for studying Sr isotopic fractionation and source identification. This has been attributed to the advancement in multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS), allows to determine precisely and simultaneously of the triple Sr isotopes. In this study, we applied a modified empirical external normalization (EEN) MC-ICPMS procedure for mass bias correction in Sr isotopic measurement using (92)Zr/(90)Zr. High-purity Zr Standard was spiked into sample solutions and the degree of fractionation was calculated off-line using an exponential law. The long-term external reproducibility for NIST SRM 987 δ(87)Sr and δ(88)Sr was better than 0.040‰ and 0.018‰ (2SD), respectively. The IAPSO standard seawater was used as a secondary standard to validate the analytical protocol and the absolute ratios measured were 0.709161±0.000018 for (87)Sr/(86)Sr, 0.177±0.021‰ for δ(87)Sr, and 0.370±0.026‰ for δ(88)Sr (2SD, n=7). These values are in good agreement with the literature data analyzed by thermal ionization mass spectrometry (TIMS) double spike technique. Rock standards, BHVO-2, BCR-2 and AGV-2 were also analyzed to validate the robustness of the methodology and showed identical results with literature data. Compared to previous (91)Zr/(90)Zr correction, we obtained improved results based on (92)Zr/(90)Zr, probably due to similar mass difference between (92)Zr/(90)Zr and measured Sr isotopes. The new analytical protocol presented in this study not only improves the analytical precision but also increases sample efficiency by omitting the use of the standard-sample bracketing (SSB) procedure. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Validation of a liquid chromatography-tandem mass spectrometry method for the detection of nicotine biomarkers in hair and an evaluation of wash procedures for removal of environmental nicotine.

    PubMed

    Miller, Eleanor I; Murray, Gordon J; Rollins, Douglas E; Tiffany, Stephen T; Wilkins, Diana G

    2011-07-01

    The aim of this exploratory study was to develop and validate a liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the quantification of nicotine, eight nicotine metabolites, and two minor tobacco alkaloids in fortified analyte-free hair and subsequently apply this method to hair samples collected from active smokers. An additional aim of the study was to include an evaluation of different wash procedures for the effective removal of environmentally deposited nicotine from tobacco smoke. An apparatus was designed for the purpose of exposing analyte-free hair to environmental tobacco smoke in order to deposit nicotine onto the hair surface. A shampoo/water wash procedure was identified as the most effective means of removing nicotine. This wash procedure was utilized for a comparison of washed and unwashed heavy smoker hair samples. Analytes and corresponding deuterated internal standards were extracted using a cation-exchange solid-phase cartridge. LC-MS-MS was carried out using an Acquity™ UPLC(®) system (Waters) and a Quattro Premier XE™ triple quadrupole MS (Waters) operated in electrospray positive ionization mode, with multiple reaction monitoring data acquisition. The developed method was applied to hair samples collected from heavy smokers (n = 3) and low-level smokers (n = 3) collected through IRB-approved protocols. Nicotine, cotinine, and nornicotine were quantified in both the washed and unwashed hair samples collected from three heavy smokers, whereas 3-hydroxycotinine was quantified in only one unwashed sample and nicotine-1'-oxide in the washed and unwashed hair samples from two heavy smokers. In contrast, nicotine-1'-oxide was quantified in one of the three low-level smoker samples; nicotine was quantified in the other two low-level smoker samples. No other analytes were detected in the hair of the three low-level smokers.

  9. Building America House Simulation Protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hendron, Robert; Engebrecht, Cheryn

    2010-09-01

    The House Simulation Protocol document was developed to track and manage progress toward Building America's multi-year, average whole-building energy reduction research goals for new construction and existing homes, using a consistent analytical reference point. This report summarizes the guidelines for developing and reporting these analytical results in a consistent and meaningful manner for all home energy uses using standard operating conditions.

  10. Reference Standardization for Mass Spectrometry and High-resolution Metabolomics Applications to Exposome Research.

    PubMed

    Go, Young-Mi; Walker, Douglas I; Liang, Yongliang; Uppal, Karan; Soltow, Quinlyn A; Tran, ViLinh; Strobel, Frederick; Quyyumi, Arshed A; Ziegler, Thomas R; Pennell, Kurt D; Miller, Gary W; Jones, Dean P

    2015-12-01

    The exposome is the cumulative measure of environmental influences and associated biological responses throughout the lifespan, including exposures from the environment, diet, behavior, and endogenous processes. A major challenge for exposome research lies in the development of robust and affordable analytic procedures to measure the broad range of exposures and associated biologic impacts occurring over a lifetime. Biomonitoring is an established approach to evaluate internal body burden of environmental exposures, but use of biomonitoring for exposome research is often limited by the high costs associated with quantification of individual chemicals. High-resolution metabolomics (HRM) uses ultra-high resolution mass spectrometry with minimal sample preparation to support high-throughput relative quantification of thousands of environmental, dietary, and microbial chemicals. HRM also measures metabolites in most endogenous metabolic pathways, thereby providing simultaneous measurement of biologic responses to environmental exposures. The present research examined quantification strategies to enhance the usefulness of HRM data for cumulative exposome research. The results provide a simple reference standardization protocol in which individual chemical concentrations in unknown samples are estimated by comparison to a concurrently analyzed, pooled reference sample with known chemical concentrations. The approach was tested using blinded analyses of amino acids in human samples and was found to be comparable to independent laboratory results based on surrogate standardization or internal standardization. Quantification was reproducible over a 13-month period and extrapolated to thousands of chemicals. The results show that reference standardization protocol provides an effective strategy that will enhance data collection for cumulative exposome research. In principle, the approach can be extended to other types of mass spectrometry and other analytical methods. © The Author 2015. Published by Oxford University Press on behalf of the Society of Toxicology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  11. Reference Standardization for Mass Spectrometry and High-resolution Metabolomics Applications to Exposome Research

    PubMed Central

    Go, Young-Mi; Walker, Douglas I.; Liang, Yongliang; Uppal, Karan; Soltow, Quinlyn A.; Tran, ViLinh; Strobel, Frederick; Quyyumi, Arshed A.; Ziegler, Thomas R.; Pennell, Kurt D.; Miller, Gary W.; Jones, Dean P.

    2015-01-01

    The exposome is the cumulative measure of environmental influences and associated biological responses throughout the lifespan, including exposures from the environment, diet, behavior, and endogenous processes. A major challenge for exposome research lies in the development of robust and affordable analytic procedures to measure the broad range of exposures and associated biologic impacts occurring over a lifetime. Biomonitoring is an established approach to evaluate internal body burden of environmental exposures, but use of biomonitoring for exposome research is often limited by the high costs associated with quantification of individual chemicals. High-resolution metabolomics (HRM) uses ultra-high resolution mass spectrometry with minimal sample preparation to support high-throughput relative quantification of thousands of environmental, dietary, and microbial chemicals. HRM also measures metabolites in most endogenous metabolic pathways, thereby providing simultaneous measurement of biologic responses to environmental exposures. The present research examined quantification strategies to enhance the usefulness of HRM data for cumulative exposome research. The results provide a simple reference standardization protocol in which individual chemical concentrations in unknown samples are estimated by comparison to a concurrently analyzed, pooled reference sample with known chemical concentrations. The approach was tested using blinded analyses of amino acids in human samples and was found to be comparable to independent laboratory results based on surrogate standardization or internal standardization. Quantification was reproducible over a 13-month period and extrapolated to thousands of chemicals. The results show that reference standardization protocol provides an effective strategy that will enhance data collection for cumulative exposome research. In principle, the approach can be extended to other types of mass spectrometry and other analytical methods. PMID:26358001

  12. Multi-site study of additive genetic effects on fractional anisotropy of cerebral white matter: Comparing meta and megaanalytical approaches for data pooling.

    PubMed

    Kochunov, Peter; Jahanshad, Neda; Sprooten, Emma; Nichols, Thomas E; Mandl, René C; Almasy, Laura; Booth, Tom; Brouwer, Rachel M; Curran, Joanne E; de Zubicaray, Greig I; Dimitrova, Rali; Duggirala, Ravi; Fox, Peter T; Hong, L Elliot; Landman, Bennett A; Lemaitre, Hervé; Lopez, Lorna M; Martin, Nicholas G; McMahon, Katie L; Mitchell, Braxton D; Olvera, Rene L; Peterson, Charles P; Starr, John M; Sussmann, Jessika E; Toga, Arthur W; Wardlaw, Joanna M; Wright, Margaret J; Wright, Susan N; Bastin, Mark E; McIntosh, Andrew M; Boomsma, Dorret I; Kahn, René S; den Braber, Anouk; de Geus, Eco J C; Deary, Ian J; Hulshoff Pol, Hilleke E; Williamson, Douglas E; Blangero, John; van 't Ent, Dennis; Thompson, Paul M; Glahn, David C

    2014-07-15

    Combining datasets across independent studies can boost statistical power by increasing the numbers of observations and can achieve more accurate estimates of effect sizes. This is especially important for genetic studies where a large number of observations are required to obtain sufficient power to detect and replicate genetic effects. There is a need to develop and evaluate methods for joint-analytical analyses of rich datasets collected in imaging genetics studies. The ENIGMA-DTI consortium is developing and evaluating approaches for obtaining pooled estimates of heritability through meta-and mega-genetic analytical approaches, to estimate the general additive genetic contributions to the intersubject variance in fractional anisotropy (FA) measured from diffusion tensor imaging (DTI). We used the ENIGMA-DTI data harmonization protocol for uniform processing of DTI data from multiple sites. We evaluated this protocol in five family-based cohorts providing data from a total of 2248 children and adults (ages: 9-85) collected with various imaging protocols. We used the imaging genetics analysis tool, SOLAR-Eclipse, to combine twin and family data from Dutch, Australian and Mexican-American cohorts into one large "mega-family". We showed that heritability estimates may vary from one cohort to another. We used two meta-analytical (the sample-size and standard-error weighted) approaches and a mega-genetic analysis to calculate heritability estimates across-population. We performed leave-one-out analysis of the joint estimates of heritability, removing a different cohort each time to understand the estimate variability. Overall, meta- and mega-genetic analyses of heritability produced robust estimates of heritability. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Development of a dynamic headspace gas chromatography-mass spectrometry method for on-site analysis of sulfur mustard degradation products in sediments.

    PubMed

    Magnusson, R; Nordlander, T; Östin, A

    2016-01-15

    Sampling teams performing work at sea in areas where chemical munitions may have been dumped require rapid and reliable analytical methods for verifying sulfur mustard leakage from suspected objects. Here we present such an on-site analysis method based on dynamic headspace GC-MS for analysis of five cyclic sulfur mustard degradation products that have previously been detected in sediments from chemical weapon dumping sites: 1,4-oxathiane, 1,3-dithiolane, 1,4-dithiane, 1,4,5-oxadithiephane, and 1,2,5-trithiephane. An experimental design involving authentic Baltic Sea sediments spiked with the target analytes was used to develop an optimized protocol for sample preparation, headspace extraction and analysis that afforded recoveries of up to 60-90%. The optimized method needs no organic solvents, uses only two grams of sediment on a dry weight basis and involves a unique sample presentation whereby sediment is spread uniformly as a thin layer inside the walls of a glass headspace vial. The method showed good linearity for analyte concentrations of 5-200 ng/g dw, good repeatability, and acceptable carry-over. The method's limits of detection for spiked sediment samples ranged from 2.5 to 11 μg/kg dw, with matrix interference being the main limiting factor. The instrumental detection limits were one to two orders of magnitude lower. Full-scan GC-MS analysis enabled the use of automated mass spectral deconvolution for rapid identification of target analytes. Using this approach, analytes could be identified in spiked sediment samples at concentrations down to 13-65 μg/kg dw. On-site validation experiments conducted aboard the research vessel R/V Oceania demonstrated the method's practical applicability, enabling the successful identification of four cyclic sulfur mustard degradation products at concentrations of 15-308μg/kg in sediments immediately after being collected near a wreck at the Bornholm Deep dumpsite in the Baltic Sea. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Development of Analytical Protocols For Organics and Isotopes Analysis on the 2009 MARS Science Laboratory.

    NASA Technical Reports Server (NTRS)

    Mahaffy, P. R.

    2006-01-01

    The Mars Science Laboratory, under development for launch in 2009, is designed explore and quantitatively asses a local region on Mars as a potential habitat for present or past life. Its ambitious goals are to (1) assess the past or present biological potential of the target environment, (2) to characterize the geology and geochemistry at the MSL landing site, and (3) to investigate planetary processes that influence habitability. The planned capabilities of the rover payload will enable a comprehensive search for organic molecules, a determination of definitive mineralogy of sampled rocks and fines, chemical and isotopic analysis of both atmospheric and solid samples, and precision isotope measurements of several volatile elements. A range of contact and remote surface and subsurface survey tools will establish context for these measurements and will facilitate sample identification and selection. The Sample Analysis at Mars (SAM) suite of MSL addresses several of the mission's core measurement goals. It includes a gas chromatograph, a mass spectrometer, and a tunable laser spectrometer. These instruments will be designed to analyze either atmospheric samples or gases extracted from solid phase samples such as rocks and fines. We will describe the range of measurement protocols under development and study by the SAM engineering and science teams for use on the surface of Mars.

  15. Development of a passive sampler for gaseous mercury

    NASA Astrophysics Data System (ADS)

    Gustin, M. S.; Lyman, S. N.; Kilner, P.; Prestbo, E.

    2011-10-01

    Here we describe work toward development of the components of a cost effective passive sampling system for gaseous Hg that could be broadly deployed by nontechnical staff. The passive sampling system included an external shield to reduce turbulence and exposure to precipitation and dust, a diffusive housing that directly protects the collection surface during deployment and handling, and a collection surface. A protocol for cleaning and deploying the sampler and an analytical method were developed. Our final design consisted of a polycarbonate external shield enclosing a custom diffusive housing made from expanded PTFE tubing. Two collection surfaces were investigated, gold sputter-coated quartz plates and silver wires. Research showed the former would require extensive quality control for use, while the latter had interferences with other atmosphere constituents. Although the gold surface exhibited the best performance over space and time, gradual passivation would limit reuse. For both surfaces lack of contamination during shipping, deployment and storage indicated that the handling protocols developed worked well with nontechnical staff. We suggest that the basis for this passive sampling system is sound, but further exploration and development of a reliable collection surface is needed.

  16. Development of analytical methods for multiplex bio-assay with inductively coupled plasma mass spectrometry

    PubMed Central

    Ornatsky, Olga I.; Kinach, Robert; Bandura, Dmitry R.; Lou, Xudong; Tanner, Scott D.; Baranov, Vladimir I.; Nitz, Mark; Winnik, Mitchell A.

    2008-01-01

    Advances in the development of highly multiplexed bio-analytical assays with inductively coupled plasma mass spectrometry (ICP-MS) detection are discussed. Use of novel reagents specifically designed for immunological methods utilizing elemental analysis is presented. The major steps of method development, including selection of elements for tags, validation of tagged reagents, and examples of multiplexed assays, are considered in detail. The paper further describes experimental protocols for elemental tagging of antibodies, immunostaining of live and fixed human leukemia cells, and preparation of samples for ICP-MS analysis. Quantitative analysis of surface antigens on model cell lines using a cocktail of seven lanthanide labeled antibodies demonstrated high specificity and concordance with conventional immunophenotyping. PMID:19122859

  17. Non-porous membrane-assisted liquid-liquid extraction of UV filter compounds from water samples.

    PubMed

    Rodil, Rosario; Schrader, Steffi; Moeder, Monika

    2009-06-12

    A method for the determination of nine UV filter compounds [benzophenone-3 (BP-3), isoamyl methoxycinnamate, 4-methylbenzylidene camphor, octocrylene (OC), butyl methoxydibenzoylmethane, ethylhexyl dimethyl p-aminobenzoate (OD-PABA), ethylhexyl methoxycinnamate (EHMC), ethylhexyl salicylate and homosalate] in water samples was developed and evaluated. The procedure includes non-porous membrane-assisted liquid-liquid extraction (MALLE) and LC-atmospheric pressure photoionization (APPI)-MS/MS. Membrane bags made of different polymeric materials were examined to enable a fast and simple extraction of the target analytes. Among the polymeric materials tested, low- and high-density polyethylene membranes proved to be well suited to adsorb the analytes from water samples. Finally, 2 cm length tailor-made membrane bags were prepared from low-density polyethylene in order to accommodate 100 microL of propanol. The fully optimised protocol provides recoveries from 76% to 101% and limits of detection (LOD) between 0.4 ng L(-1) (OD-PABA) and 16 ng L(-1) (EHMC). The interday repeatability of the whole protocol was below 18%. The effective separation of matrix molecules was proved by only marginal matrix influence during the APPI-MS analysis since no ion suppression effects were observed. During the extraction step, the influence of the matrix was only significant when non-treated wastewater was analysed. The analysis of lake water indicated the presence of seven UV filter compounds included in this study at concentrations between 40 ng L(-1) (BP-3) and 4381 ng L(-1) (OC). In non-treated wastewater several UV filters were also detected at concentration levels as high as 5322 ng L(-1) (OC).

  18. What a drop can do: dried blood spots as a minimally invasive method for integrating biomarkers into population-based research.

    PubMed

    McDade, Thomas W; Williams, Sharon; Snodgrass, J Josh

    2007-11-01

    Logistical constraints associated with the collection and analysis of biological samples in community-based settings have been a significant impediment to integrative, multilevel bio-demographic and biobehavioral research. However recent methodological developments have overcome many of these constraints and have also expanded the options for incorporating biomarkers into population-based health research in international as well as domestic contexts. In particular using dried blood spot (DBS) samples-drops of whole blood collected on filter paper from a simple finger prick-provides a minimally invasive method for collecting blood samples in nonclinical settings. After a brief discussion of biomarkers more generally, we review procedures for collecting, handling, and analyzing DBS samples. Advantages of using DBS samples-compared with venipuncture include the relative ease and low cost of sample collection, transport, and storage. Disadvantages include requirements for assay development and validation as well as the relatively small volumes of sample. We present the results of a comprehensive literature review of published protocols for analysis of DBS samples, and we provide more detailed analysis of protocols for 45 analytes likely to be of particular relevance to population-level health research. Our objective is to provide investigators with the information they need to make informed decisions regarding the appropriateness of blood spot methods for their research interests.

  19. Exposure Assessment of Acetamide in Milk, Beef, and Coffee Using Xanthydrol Derivatization and Gas Chromatography/Mass Spectrometry

    PubMed Central

    2017-01-01

    Acetamide has been classified as a possible human carcinogen, but uncertainties exist about its levels in foods. This report presents evidence that thermal decomposition of N-acetylated sugars and amino acids in heated gas chromatograph injectors contributes to artifactual acetamide in milk and beef. An alternative gas chromatography/mass spectrometry protocol based on derivatization of acetamide with 9-xanthydrol was optimized and shown to be free of artifactual acetamide formation. The protocol was validated using a surrogate analyte approach based on d3-acetamide and applied to analyze 23 pasteurized whole milk, 44 raw sirloin beef, and raw milk samples from 14 different cows, and yielded levels about 10-fold lower than those obtained by direct injection without derivatization. The xanthydrol derivatization procedure detected acetamide in every food sample tested at 390 ± 60 ppb in milk, 400 ± 80 ppb in beef, and 39 000 ± 9000 ppb in roasted coffee beans. PMID:29186951

  20. Plant iTRAQ-based proteomics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Handakumbura, Pubudu; Hixson, Kim K.; Purvine, Samuel O.

    We present a simple one-­pot extraction protocol, which rapidly isolates hydrophyllic metabolites, lipids, and proteins from the same pulverized plant sample. Also detailed is a global plant proteomics sample preparation method utilizing iTRAQ multiplexing reagents that enables deep proteome coverage due to the use of HPLC fractionation of the peptides prior to mass spectrometric analysis. We have successfully used this protocol on several different plant tissues (e.g., roots, stems, leaves) from different plants (e.g., sorghum, poplar, Arabidopsis, soybean), and have been able to successfully detect and quantify thousands of proteins. Multiplexing strategies such as iTRAQ and the bioinformatics strategy outlinedmore » here, ultimately provide insight into which proteins are significantly changed in abundance between two or more groups (e.g., control, perturbation). Our bioinformatics strategy yields z-­score values, which normalize the expression data into a format that can easily be cross-­compared with other expression data (i.e., metabolomics, transcriptomics) obtained from different analytical methods and instrumentation.« less

  1. Cluster Size Optimization in Sensor Networks with Decentralized Cluster-Based Protocols

    PubMed Central

    Amini, Navid; Vahdatpour, Alireza; Xu, Wenyao; Gerla, Mario; Sarrafzadeh, Majid

    2011-01-01

    Network lifetime and energy-efficiency are viewed as the dominating considerations in designing cluster-based communication protocols for wireless sensor networks. This paper analytically provides the optimal cluster size that minimizes the total energy expenditure in such networks, where all sensors communicate data through their elected cluster heads to the base station in a decentralized fashion. LEACH, LEACH-Coverage, and DBS comprise three cluster-based protocols investigated in this paper that do not require any centralized support from a certain node. The analytical outcomes are given in the form of closed-form expressions for various widely-used network configurations. Extensive simulations on different networks are used to confirm the expectations based on the analytical results. To obtain a thorough understanding of the results, cluster number variability problem is identified and inspected from the energy consumption point of view. PMID:22267882

  2. Preparation of A Spaceflight: Apoptosis Search in Sutured Wound Healing Models.

    PubMed

    Riwaldt, Stefan; Monici, Monica; Graver Petersen, Asbjørn; Birk Jensen, Uffe; Evert, Katja; Pantalone, Desiré; Utpatel, Kirsten; Evert, Matthias; Wehland, Markus; Krüger, Marcus; Kopp, Sascha; Frandsen, Sofie; Corydon, Thomas; Sahana, Jayashree; Bauer, Johann; Lützenberg, Ronald; Infanger, Manfred; Grimm, Daniela

    2017-12-03

    To prepare the ESA (European Space Agency) spaceflight project "Wound healing and Sutures in Unloading Conditions", we studied mechanisms of apoptosis in wound healing models based on ex vivo skin tissue cultures, kept for 10 days alive in serum-free DMEM/F12 medium supplemented with bovine serum albumin, hydrocortisone, insulin, ascorbic acid and antibiotics at 32 °C. The overall goal is to test: (i) the viability of tissue specimens; (ii) the gene expression of activators and inhibitors of apoptosis and extracellular matrix components in wound and suture models; and (iii) to design analytical protocols for future tissue specimens after post-spaceflight download. Hematoxylin-Eosin and Elastica-van-Gieson staining showed a normal skin histology with no signs of necrosis in controls and showed a normal wound suture. TdT-mediated dUTP-biotin nick end labeling for detecting DNA fragmentation revealed no significant apoptosis. No activation of caspase-3 protein was detectable. FASL , FADD , CASP3 , CASP8 , CASP10 , BAX , BCL2 , CYC1 , APAF1 , LAMA3 and SPP1 mRNAs were not altered in epidermis and dermis samples with and without a wound compared to 0 day samples (specimens investigated directly post-surgery). BIRC5 , CASP9 , and FN1 mRNAs were downregulated in epidermis/dermis samples with and/or without a wound compared to 0 day samples. BIRC2 , BIRC3 were upregulated in 10 day wound samples compared to 0 day samples in epidermis/dermis. RELA/FAS mRNAs were elevated in 10 day wound and no wound samples compared to 0 day samples in dermis. In conclusion, we demonstrate that it is possible to maintain live skin tissue cultures for 10 days. The viability analysis showed no significant signs of cell death in wound and suture models. The gene expression analysis demonstrated the interplay of activators and inhibitors of apoptosis and extracellular matrix components, thereby describing important features in ex vivo sutured wound healing models. Collectively, the performed methods defining analytical protocols proved to be applicable for post-flight analyzes of tissue specimens after sample return.

  3. The Successful Diagnosis and Typing of Systemic Amyloidosis Using A Microwave-Assisted Filter-Aided Fast Sample Preparation Method and LC/MS/MS Analysis

    PubMed Central

    Zou, Lili; Shen, Kaini; Zhong, Dingrong; Zhou, Daobin; Sun, Wei; Li, Jian

    2015-01-01

    Laser microdissection followed by mass spectrometry has been successfully used for amyloid typing. However, sample contamination can interfere with proteomic analysis, and overnight digestion limits the analytical throughput. Moreover, current quantitative analysis methods are based on the spectrum count, which ignores differences in protein length and may lead to misdiagnoses. Here, we developed a microwave-assisted filter-aided sample preparation (maFASP) method that can efficiently remove contaminants with a 10-kDa cutoff ultrafiltration unit and can accelerate the digestion process with the assistance of a microwave. Additionally, two parameters (P- and D-scores) based on the exponentially modified protein abundance index were developed to define the existence of amyloid deposits and those causative proteins with the greatest abundance. Using our protocol, twenty cases of systemic amyloidosis that were well-typed according to clinical diagnostic standards (training group) and another twenty-four cases without subtype diagnoses (validation group) were analyzed. Using this approach, sample preparation could be completed within four hours. We successfully subtyped 100% of the cases in the training group, and the diagnostic success rate in the validation group was 91.7%. This maFASP-aided proteomic protocol represents an efficient approach for amyloid diagnosis and subtyping, particularly for serum-contaminated samples. PMID:25984759

  4. Peptidome characterization and bioactivity analysis of donkey milk.

    PubMed

    Piovesana, Susy; Capriotti, Anna Laura; Cavaliere, Chiara; La Barbera, Giorgia; Samperi, Roberto; Zenezini Chiozzi, Riccardo; Laganà, Aldo

    2015-04-24

    Donkey milk is an interesting commercial product for its nutritional values, which make it the most suitable mammalian milk for human consumption, and for the bioactivity associated with it and derivative products. To further mine the characterization of donkey milk, an extensive peptidomic study was performed. Two peptide purification strategies were compared to remove native proteins and lipids and enrich the peptide fraction. In one case the whole protein content was precipitated by organic solvent using cold acetone. In the other one the precipitation of the most abundant milk proteins, caseins, was performed under acidic conditions by acetic acid at pH4.6, instead. The procedures were compared and proved to be partially complementary. Considered together they provided 1330 peptide identifications for donkey milk, mainly coming from the most abundant proteins in milk. The bioactivity of the isolated peptides was also investigated, both by angiotensin-converting-enzyme inhibitory and antioxidant activity assays and by bioinformatics, proving that the isolated peptides did have the tested biological activities. The rationale behind this study is that peptides in food matrices often play an important biological role and, despite the extensive study of the protein composition of different samples, they remain poorly characterized. In fact, in a typical shotgun proteomics study endogenous peptides are not properly characterized. In proteomics workflows one limiting point is the isolation process: if it is specific for the purification of proteins, it often comprises a precipitation step which aims at isolating pure protein pellets and remove unwonted interferent compounds. In this way endogenous peptides, which are not effectively precipitated as well as proteins, are removed too and not analyzed at the end of the process. Moreover, endogenous peptides do often originate from precursor proteins, but in phenomena which are independent of the shotgun digestion protocol, thus they can be obtained from cleavage specificities other than trypsin's, which is the main proteolytic enzyme employed in proteomic experiments. For this reason, in the end, database search will not be effective for identification of these peptides, thus the need to provide different workflows for peptide analysis. In the work presented in this paper this issue is considered for the first time for the analysis of the peptides isolated in donkey milk samples, which have been chosen for its nutritional interest. This study provides additional knowledge on this milk, already characterized by traditional proteomics studies and peptidomic studies after simulated digestion. This type of study is not just a description of the naturally occurring peptidome of a sample, but also represents a starting point to discover and characterize those naturally occurring peptides responsible for the observed bioactivities of biological samples, as in the case of donkey milk, which would remain uncharacterized by other approaches. In this paper an analytical protocol was described for the efficient isolation and purification of peptides in donkey milk, assessing the effect of the purification protocol on the final identifications. Purified peptide samples were also checked to empirically elucidate any ACE inhibitory or antioxidant activity. Finally, the peptidomic results were also further mined by a bioinformatic-driven approach for bioactive peptide identification in the donkey milk samples. In our opinion, the main strengths of this study are related to the improved analytical workflow (either as purification protocol comparison or analytical platform development) which provides a high number of identified peptides, for which the biological significance as potential bioactive peptides has also been investigated. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Toroid cavity/coil NMR multi-detector

    DOEpatents

    Gerald, II, Rex E.; Meadows, Alexander D.; Gregar, Joseph S.; Rathke, Jerome W.

    2007-09-18

    An analytical device for rapid, non-invasive nuclear magnetic resonance (NMR) spectroscopy of multiple samples using a single spectrometer is provided. A modified toroid cavity/coil detector (TCD), and methods for conducting the simultaneous acquisition of NMR data for multiple samples including a protocol for testing NMR multi-detectors are provided. One embodiment includes a plurality of LC resonant circuits including spatially separated toroid coil inductors, each toroid coil inductor enveloping its corresponding sample volume, and tuned to resonate at a predefined frequency using a variable capacitor. The toroid coil is formed into a loop, where both ends of the toroid coil are brought into coincidence. Another embodiment includes multiple micro Helmholtz coils arranged on a circular perimeter concentric with a central conductor of the toroid cavity.

  6. Soil Geochemical Data for the Wyoming Landscape Conservation Initiative Study Area

    USGS Publications Warehouse

    Smith, David B.; Ellefsen, Karl J.

    2010-01-01

    In 2008, soil samples were collected at 139 sites throughout the Wyoming Landscape Conservation Initiative study area in southwest Wyoming. These samples, representing a density of 1 site per 440 square kilometers, were collected from a depth of 0-5 cm and analyzed for a suite of more than 40 major and trace elements following a near-total multi-acid extraction. In addition, soil pH, electrical conductivity, total nitrogen, total and organic carbon, and sodium adsorption ratio were determined. The resulting data set provides a baseline for detecting changes in soil composition that might result from natural processes or anthropogenic activities. This report describes the sampling and analytical protocols used, and makes available all the soil geochemical data generated in the study.

  7. 40 CFR Appendix A - Protocol for Using an Electrochemical Analyzer to Determine Oxygen and Carbon Monoxide...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., and Process Heaters Using Portable Analyzers”, EMC Conditional Test Protocol 30 (CTM-30), Gas Research... cell design(s) conforming to this protocol will determine the analytical range for each gas component..., selective gas scrubbers, etc.) to meet the design specifications of this protocol. Do not make changes to...

  8. 40 CFR Appendix A - Protocol for Using an Electrochemical Analyzer to Determine Oxygen and Carbon Monoxide...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., and Process Heaters Using Portable Analyzers”, EMC Conditional Test Protocol 30 (CTM-30), Gas Research... cell design(s) conforming to this protocol will determine the analytical range for each gas component..., selective gas scrubbers, etc.) to meet the design specifications of this protocol. Do not make changes to...

  9. MICROORGANISMS IN BIOSOLIDS: ANALYTICAL METHODS DEVELOPMENT, STANDARDIZATION, AND VALIDATION

    EPA Science Inventory

    The objective of this presentation is to discuss pathogens of concern in biosolids, the analytical techniques used to evaluate microorganisms in biosolids, and to discuss standardization and validation of analytical protocols for microbes within such a complex matrix. Implicatio...

  10. Micelle assisted thin-film solid phase microextraction: a new approach for determination of quaternary ammonium compounds in environmental samples.

    PubMed

    Boyacı, Ezel; Pawliszyn, Janusz

    2014-09-16

    Determination of quaternary ammonium compounds (QACs) often is considered to be a challenging undertaking owing to secondary interactions of the analytes' permanently charged quaternary ammonium head or hydrophobic tail with the utilized labware. Here, for the first time, a micelle assisted thin-film solid phase microextraction (TF-SPME) using a zwitterionic detergent 3-[(3-cholamidopropyl)dimethylammonio]-1-propanesulfonate (CHAPS) as a matrix modifier is introduced as a novel approach for in-laboratory sample preparation of the challenging compounds. The proposed micelle assisted TF-SPME method offers suppression/enhancement free electrospray ionization of analytes in mass spectrometric detection, minimal interaction of the micelles with the TF-SPME coating, and chromatographic stationary phase and analysis free of secondary interactions. Moreover, it was found that the matrix modifier has multiple functions; when its concentration is found below the critical micelle concentration (CMC), the matrix modifier primarily acts as a surface deactivator; above its CMC, it acts as a stabilizer for QACs. Additionally, shorter equilibrium extraction times in the presence of the modifier demonstrated that micelles also assist in the transfer of analytes from the bulk of the sample to the surface of the coating. The developed micelle assisted TF-SPME protocol using the 96-blade system requires only 30 min of extraction and 15 min of desorption. Together with a conditioning step (15 min), the entire method is 60 min; considering the advantage of using the 96-blade system, if all the blades in the brush are used, the sample preparation time per sample is 0.63 min. Moreover, the recoveries for all analytes with the developed method were found to range within 80.2-97.3%; as such, this method can be considered an open bed solid phase extraction. The proposed method was successfully validated using real samples.

  11. Automated processing of whole blood samples for the determination of immunosuppressants by liquid chromatography tandem-mass spectrometry.

    PubMed

    Vogeser, Michael; Spöhrer, Ute

    2006-01-01

    Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is an efficient technology for routine determination of immunosuppressants in whole blood; however, time-consuming manual sample preparation remains a significant limitation of this technique. Using a commercially available robotic pipetting system (Tecan Freedom EVO), we developed an automated sample-preparation protocol for quantification of tacrolimus in whole blood by LC-MS/MS. Barcode reading, sample resuspension, transfer of whole blood aliquots into a deep-well plate, addition of internal standard solution, mixing, and protein precipitation by addition of an organic solvent is performed by the robotic system. After centrifugation of the plate, the deproteinized supernatants are submitted to on-line solid phase extraction, using column switching prior to LC-MS/MS analysis. The only manual actions within the entire process are decapping of the tubes, and transfer of the deep-well plate from the robotic system to a centrifuge and finally to the HPLC autosampler. Whole blood pools were used to assess the reproducibility of the entire analytical system for measuring tacrolimus concentrations. A total coefficient of variation of 1.7% was found for the entire automated analytical process (n=40; mean tacrolimus concentration, 5.3 microg/L). Close agreement between tacrolimus results obtained after manual and automated sample preparation was observed. The analytical system described here, comprising automated protein precipitation, on-line solid phase extraction and LC-MS/MS analysis, is convenient and precise, and minimizes hands-on time and the risk of mistakes in the quantification of whole blood immunosuppressant concentrations compared to conventional methods.

  12. Sources of Pre-Analytical Variations in Yield of DNA Extracted from Blood Samples: Analysis of 50,000 DNA Samples in EPIC

    PubMed Central

    Caboux, Elodie; Lallemand, Christophe; Ferro, Gilles; Hémon, Bertrand; Mendy, Maimuna; Biessy, Carine; Sims, Matt; Wareham, Nick; Britten, Abigail; Boland, Anne; Hutchinson, Amy; Siddiq, Afshan; Vineis, Paolo; Riboli, Elio; Romieu, Isabelle; Rinaldi, Sabina; Gunter, Marc J.; Peeters, Petra H. M.; van der Schouw, Yvonne T.; Travis, Ruth; Bueno-de-Mesquita, H. Bas; Canzian, Federico; Sánchez, Maria-José; Skeie, Guri; Olsen, Karina Standahl; Lund, Eiliv; Bilbao, Roberto; Sala, Núria; Barricarte, Aurelio; Palli, Domenico; Navarro, Carmen; Panico, Salvatore; Redondo, Maria Luisa; Polidoro, Silvia; Dossus, Laure; Boutron-Ruault, Marie Christine; Clavel-Chapelon, Françoise; Trichopoulou, Antonia; Trichopoulos, Dimitrios; Lagiou, Pagona; Boeing, Heiner; Fisher, Eva; Tumino, Rosario; Agnoli, Claudia; Hainaut, Pierre

    2012-01-01

    The European Prospective Investigation into Cancer and nutrition (EPIC) is a long-term, multi-centric prospective study in Europe investigating the relationships between cancer and nutrition. This study has served as a basis for a number of Genome-Wide Association Studies (GWAS) and other types of genetic analyses. Over a period of 5 years, 52,256 EPIC DNA samples have been extracted using an automated DNA extraction platform. Here we have evaluated the pre-analytical factors affecting DNA yield, including anthropometric, epidemiological and technical factors such as center of subject recruitment, age, gender, body-mass index, disease case or control status, tobacco consumption, number of aliquots of buffy coat used for DNA extraction, extraction machine or procedure, DNA quantification method, degree of haemolysis and variations in the timing of sample processing. We show that the largest significant variations in DNA yield were observed with degree of haemolysis and with center of subject recruitment. Age, gender, body-mass index, cancer case or control status and tobacco consumption also significantly impacted DNA yield. Feedback from laboratories which have analyzed DNA with different SNP genotyping technologies demonstrate that the vast majority of samples (approximately 88%) performed adequately in different types of assays. To our knowledge this study is the largest to date to evaluate the sources of pre-analytical variations in DNA extracted from peripheral leucocytes. The results provide a strong evidence-based rationale for standardized recommendations on blood collection and processing protocols for large-scale genetic studies. PMID:22808065

  13. Development of a HS-SPME-GC/MS protocol assisted by chemometric tools to study herbivore-induced volatiles in Myrcia splendens.

    PubMed

    Souza Silva, Érica A; Saboia, Giovanni; Jorge, Nina C; Hoffmann, Camila; Dos Santos Isaias, Rosy Mary; Soares, Geraldo L G; Zini, Claudia A

    2017-12-01

    A headspace solid phase microextraction (HS-SPME) method combined with gas chromatography-mass spectrometry (GC/MS) was developed and optimized for extraction and analysis of volatile organic compounds (VOC) of leaves and galls of Myrcia splendens. Through a process of optimization of main factors affecting HS-SPME efficiency, the coating divivnilbenzene-carboxen-polydimethylsiloxane (DVB/Car/PDMS) was chosen as the optimum extraction phase, not only in terms of extraction efficiency, but also for its broader analyte coverage. Optimum extraction temperature was 30°C, while an extraction time of 15min provided the best compromise between extraction efficiencies of lower and higher molecular weight compounds. The optimized protocol was demonstrated to be capable of sampling plant material with high reproducibility, considering that most classes of analytes met the 20% RSD FDA criterion. The optimized method was employed for the analysis of three classes of M. splendens samples, generating a final list of 65 tentatively identified VOC, including alcohols, aldehydes, esters, ketones, phenol derivatives, as well as mono and sesquiterpenes. Significant differences were evident amongst the volatile profiles obtained from non-galled leaves (NGL) and leaf-folding galls (LFG) of M. splendens. Several differences pertaining to amounts of alcohols and aldehydes were detected between samples, particularly regarding quantities of green leaf volatiles (GLV). Alcohols represented about 14% of compounds detected in gall samples, whereas in non-galled samples, alcohol content was below 5%. Phenolic derived compounds were virtually absent in reference samples, while in non-galled leaves and galls their content ranged around 0.2% and 0.4%, respectively. Likewise, methyl salicylate, a well-known signal of plant distress, amounted for 1.2% of the sample content of galls, whereas it was only present in trace levels in reference samples. Chemometric analysis based on Heatmap associated with Hierarchical Cluster Analysis (HCA) and Principal Component Analysis (PCA) provided a suitable tool to differentiate VOC profiles in vegetal material, and could open new perspectives and opportunities in agricultural and ecological studies for the detection and identification of herbivore-induced plant VOC emissions. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Analytical method for the identification and assay of 12 phthalates in cosmetic products: application of the ISO 12787 international standard "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques".

    PubMed

    Gimeno, Pascal; Maggio, Annie-Françoise; Bousquet, Claudine; Quoirez, Audrey; Civade, Corinne; Bonnet, Pierre-Antoine

    2012-08-31

    Esters of phthalic acid, more commonly named phthalates, may be present in cosmetic products as ingredients or contaminants. Their presence as contaminant can be due to the manufacturing process, to raw materials used or to the migration of phthalates from packaging when plastic (polyvinyl chloride--PVC) is used. 8 phthalates (DBP, DEHP, BBP, DMEP, DnPP, DiPP, DPP, and DiBP), classified H360 or H361, are forbidden in cosmetics according to the European regulation on cosmetics 1223/2009. A GC/MS method was developed for the assay of 12 phthalates in cosmetics, including the 8 phthalates regulated. Analyses are carried out on a GC/MS system with electron impact ionization mode (EI). The separation of phthalates is obtained on a cross-linked 5%-phenyl/95%-dimethylpolysiloxane capillary column 30 m × 0.25 mm (i.d.) × 0.25 mm film thickness using a temperature gradient. Phthalate quantification is performed by external calibration using an internal standard. Validation elements obtained on standard solutions, highlight a satisfactory system conformity (resolution>1.5), a common quantification limit at 0.25 ng injected, an acceptable linearity between 0.5 μg mL⁻¹ and 5.0 μg mL⁻¹ as well as a precision and an accuracy in agreement with in-house specifications. Cosmetic samples ready for analytical injection are analyzed after a dilution in ethanol whereas more complex cosmetic matrices, like milks and creams, are assayed after a liquid/liquid extraction using ter-butyl methyl ether (TBME). Depending on the type of cosmetics analyzed, the common limits of quantification for the 12 phthalates were set at 0.5 or 2.5 μg g⁻¹. All samples were assayed using the analytical approach described in the ISO 12787 international standard "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques". This analytical protocol is particularly adapted when it is not possible to make reconstituted sample matrices. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Ambient Mass Spectrometry Imaging Using Direct Liquid Extraction Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laskin, Julia; Lanekoff, Ingela

    2015-11-13

    Mass spectrometry imaging (MSI) is a powerful analytical technique that enables label-free spatial localization and identification of molecules in complex samples.1-4 MSI applications range from forensics5 to clinical research6 and from understanding microbial communication7-8 to imaging biomolecules in tissues.1, 9-10 Recently, MSI protocols have been reviewed.11 Ambient ionization techniques enable direct analysis of complex samples under atmospheric pressure without special sample pretreatment.3, 12-16 In fact, in ambient ionization mass spectrometry, sample processing (e.g., extraction, dilution, preconcentration, or desorption) occurs during the analysis.17 This substantially speeds up analysis and eliminates any possible effects of sample preparation on the localization of moleculesmore » in the sample.3, 8, 12-14, 18-20 Venter and co-workers have classified ambient ionization techniques into three major categories based on the sample processing steps involved: 1) liquid extraction techniques, in which analyte molecules are removed from the sample and extracted into a solvent prior to ionization; 2) desorption techniques capable of generating free ions directly from substrates; and 3) desorption techniques that produce larger particles subsequently captured by an electrospray plume and ionized.17 This review focuses on localized analysis and ambient imaging of complex samples using a subset of ambient ionization methods broadly defined as “liquid extraction techniques” based on the classification introduced by Venter and co-workers.17 Specifically, we include techniques where analyte molecules are desorbed from solid or liquid samples using charged droplet bombardment, liquid extraction, physisorption, chemisorption, mechanical force, laser ablation, or laser capture microdissection. Analyte extraction is followed by soft ionization that generates ions corresponding to intact species. Some of the key advantages of liquid extraction techniques include the ease of operation, ability to analyze samples in their native environments, speed of analysis, and ability to tune the extraction solvent composition to a problem at hand. For example, solvent composition may be optimized for efficient extraction of different classes of analytes from the sample or for quantification or online derivatization through reactive analysis. In this review, we will: 1) introduce individual liquid extraction techniques capable of localized analysis and imaging, 2) describe approaches for quantitative MSI experiments free of matrix effects, 3) discuss advantages of reactive analysis for MSI experiments, and 4) highlight selected applications (published between 2012 and 2015) that focus on imaging and spatial profiling of molecules in complex biological and environmental samples.« less

  16. Analytical Measurement of Discrete Hydrogen Sulfide Pools in Biological Specimens

    PubMed Central

    Shen, Xinggui; Peter, Elvis A.; Bir, Shyamal; Wang, Rui; Kevil, Christopher G.

    2015-01-01

    Hydrogen sulfide (H2S) is a ubiquitous gaseous signaling molecule that plays a vital role in numerous cellular functions and has become the focus of many research endeavors including pharmaco-therapeutic manipulation. Amongst the challenges facing the field is the accurate measurement of biologically active H2S. We have recently reported that the typically used methylene blue method and its associated results are invalid and do not measure bonafide H2S. The complexity of analytical H2S measurement reflects the fact that hydrogen sulfide is a volatile gas and exists in the body in different forms, including a free form, an acid labile pool and as bound sulfane sulfur. Here we describe a new protocol to discretely measure specific H2S pools using the monobromobimane method coupled with RP-HPLC. This new protocol involves selective liberation, trapping and derivatization of H2S. Acid-labile H2S is released by incubating the sample in an acidic solution (pH 2.6) of 100 mM phosphate buffer with 0.1 mM DTPA, in an enclosed system to contain volatilized H2S. Volatilized H2S is then trapped in 100 mM Tris-HCl (pH 9.5, 0.1 mM DTPA) and then reacted with excess monobromobimane. In a separate aliquot, the contribution of bound sulfane sulfur pool was measured by incubating the sample with 1 mM TCEP (Tris(2-carboxyethyl)phosphine hydrochloride), a reducing agent to reduce disulfide bonds, in 100 mM phosphate buffer (pH 2.6, 0.1 mM DTPA), and H2S measurement performed in an analogous manner to the one described above. The acid labile pool was determined by subtracting the free hydrogen sulfide value from the value obtained by the acid liberation protocol. The bound sulfane sulfur pool was determined by subtracting the H2S measurement from the acid liberation protocol alone compared to that of TCEP plus acidic conditions. In summary, our new method protocol allows very sensitive and accurate measurement of the three primary biological pools of H2S including free, acid labile, and bound sulfane sulfur in various biological specimens. PMID:22561703

  17. Multi-residue determination of the sorption of illicit drugs and pharmaceuticals to wastewater suspended particulate matter using pressurised liquid extraction, solid phase extraction and liquid chromatography coupled with tandem mass spectrometry.

    PubMed

    Baker, David R; Kasprzyk-Hordern, Barbara

    2011-11-04

    Presented is the first comprehensive study of drugs of abuse on suspended particulate matter (SPM) in wastewater. Analysis of SPM is crucial to prevent the under-reporting of the levels of analyte that may be present in wastewater. Analytical methods to date analyse the aqueous part of wastewater samples only, removing SPM through the use of filtration or centrifugation. The development of an analytical method to determine 60 compounds on SPM using a combination of pressurised liquid extraction, solid phase extraction and liquid chromatography coupled with tandem mass spectrometry (PLE-SPE-LC-MS/MS) is reported. The range of compounds monitored included stimulants, opioid and morphine derivatives, benzodiazepines, antidepressants, dissociative anaesthetics, drug precursors, and their metabolites. The method was successfully validated (parameters studied: linearity and range, recovery, accuracy, reproducibility, repeatability, matrix effects, and limits of detection and quantification). The developed methodology was applied to SPM samples collected at three wastewater treatment plants in the UK. The average proportion of analyte on SPM as opposed to in the aqueous phase was <5% for several compounds including cocaine, benzoylecgonine, MDMA, and ketamine; whereas the proportion was >10% with regard to methadone, EDDP, EMDP, BZP, fentanyl, nortramadol, norpropoxyphene, sildenafil and all antidepressants (dosulepin, amitriptyline, nortriptyline, fluoxetine and norfluoxetine). Consequently, the lack of SPM analysis in wastewater sampling protocol could lead to the under-reporting of the measured concentration of some compounds. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Quality assurance in the pre-analytical phase of human urine samples by (1)H NMR spectroscopy.

    PubMed

    Budde, Kathrin; Gök, Ömer-Necmi; Pietzner, Maik; Meisinger, Christine; Leitzmann, Michael; Nauck, Matthias; Köttgen, Anna; Friedrich, Nele

    2016-01-01

    Metabolomic approaches investigate changes in metabolite profiles, which may reflect changes in metabolic pathways and provide information correlated with a specific biological process or pathophysiology. High-resolution (1)H NMR spectroscopy is used to identify metabolites in biofluids and tissue samples qualitatively and quantitatively. This pre-analytical study evaluated the effects of storage time and temperature on (1)H NMR spectra from human urine in two settings. Firstly, to evaluate short time effects probably due to acute delay in sample handling and secondly, the effect of prolonged storage up to one month to find markers of sample miss-handling. A number of statistical procedures were used to assess the differences between samples stored under different conditions, including Projection to Latent Structure Discriminant Analysis (PLS-DA), non-parametric testing as well as mixed effect linear regression analysis. The results indicate that human urine samples can be stored at 10 °C for 24 h or at -80 °C for 1 month, as no relevant changes in (1)H NMR fingerprints were observed during these time periods and temperature conditions. However, some metabolites most likely of microbial origin showed alterations during prolonged storage but without facilitating classification. In conclusion, the presented protocol for urine sample handling and semi-automatic metabolite quantification is suitable for large-scale epidemiological studies. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Identification of polar, ionic, and highly water soluble organic pollutants in untreated industrial wastewaters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Castillo, M.; Alonso, M.C.; Riu, J.

    1999-04-15

    This paper presents a generic protocol for the determination of polar, ionic, and highly water soluble organic pollutants on untreated industrial wastewaters involving the use of two different solid-phase extraction (SPE) methodologies followed by liquid chromatography-mass spectrometry (LC-MS). Untreated industrial wastewaters might contain natural and synthetic dissolved organic compounds with total organic carbon (TOC) values varying between 100 and 3000 mg/L. All polar, ionic and highly water soluble compounds comprising more than 95% of the organic content and with major contribution to the total toxicity of the sample cannot be analyzed by conventional gas chromatography-mass spectrometry (GC-MS), and LC-MS ismore » a good alternative. In this work two extraction procedures were used to obtain fractionated extracts of the nonionic polar compounds: a polymeric Isolute ENV + SPE cartridge for the preconcentration of anionic analytes and a sequential solid-phase extraction (SSPE) method percolating the samples first in octadecylsilica cartridge in series with the polymeric Lichrolut EN cartridge. Average recoveries ranging from 72% to 103% were obtained for a variety of 23 different analytes. Determination of nonionic pollutants was accomplished by reverse-phase liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS), while anionic compounds were analyzed by ion pair chromatography-electrospray-mass spectrometry (IP-ESI-MS) and LC-ESI-MS. This protocol was applied to a pilot survey of textile and tannery wastewaters leading to the identification and quantification of 33 organic pollutants.« less

  20. Critical factors for assembling a high volume of DNA barcodes

    PubMed Central

    Hajibabaei, Mehrdad; deWaard, Jeremy R; Ivanova, Natalia V; Ratnasingham, Sujeevan; Dooh, Robert T; Kirk, Stephanie L; Mackie, Paula M; Hebert, Paul D.N

    2005-01-01

    Large-scale DNA barcoding projects are now moving toward activation while the creation of a comprehensive barcode library for eukaryotes will ultimately require the acquisition of some 100 million barcodes. To satisfy this need, analytical facilities must adopt protocols that can support the rapid, cost-effective assembly of barcodes. In this paper we discuss the prospects for establishing high volume DNA barcoding facilities by evaluating key steps in the analytical chain from specimens to barcodes. Alliances with members of the taxonomic community represent the most effective strategy for provisioning the analytical chain with specimens. The optimal protocols for DNA extraction and subsequent PCR amplification of the barcode region depend strongly on their condition, but production targets of 100K barcode records per year are now feasible for facilities working with compliant specimens. The analysis of museum collections is currently challenging, but PCR cocktails that combine polymerases with repair enzyme(s) promise future success. Barcode analysis is already a cost-effective option for species identification in some situations and this will increasingly be the case as reference libraries are assembled and analytical protocols are simplified. PMID:16214753

  1. Lipidomic analysis of biological samples: Comparison of liquid chromatography, supercritical fluid chromatography and direct infusion mass spectrometry methods.

    PubMed

    Lísa, Miroslav; Cífková, Eva; Khalikova, Maria; Ovčačíková, Magdaléna; Holčapek, Michal

    2017-11-24

    Lipidomic analysis of biological samples in a clinical research represents challenging task for analytical methods given by the large number of samples and their extreme complexity. In this work, we compare direct infusion (DI) and chromatography - mass spectrometry (MS) lipidomic approaches represented by three analytical methods in terms of comprehensiveness, sample throughput, and validation results for the lipidomic analysis of biological samples represented by tumor tissue, surrounding normal tissue, plasma, and erythrocytes of kidney cancer patients. Methods are compared in one laboratory using the identical analytical protocol to ensure comparable conditions. Ultrahigh-performance liquid chromatography/MS (UHPLC/MS) method in hydrophilic interaction liquid chromatography mode and DI-MS method are used for this comparison as the most widely used methods for the lipidomic analysis together with ultrahigh-performance supercritical fluid chromatography/MS (UHPSFC/MS) method showing promising results in metabolomics analyses. The nontargeted analysis of pooled samples is performed using all tested methods and 610 lipid species within 23 lipid classes are identified. DI method provides the most comprehensive results due to identification of some polar lipid classes, which are not identified by UHPLC and UHPSFC methods. On the other hand, UHPSFC method provides an excellent sensitivity for less polar lipid classes and the highest sample throughput within 10min method time. The sample consumption of DI method is 125 times higher than for other methods, while only 40μL of organic solvent is used for one sample analysis compared to 3.5mL and 4.9mL in case of UHPLC and UHPSFC methods, respectively. Methods are validated for the quantitative lipidomic analysis of plasma samples with one internal standard for each lipid class. Results show applicability of all tested methods for the lipidomic analysis of biological samples depending on the analysis requirements. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Incineration of polychlorinated biphenyls in high-efficiency boilers: a viable disposal option

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunt, G.T.; Wolf, P.; Fennelly, P.F.

    1984-03-01

    Approximately 750 million pounds of polychlorinated biphenyls (PCBs) remain in service today in the United States. The eventual disposition of these materials and the vast stock piles already removed from commerce and use represents a formidable problem to both U.S. industry (e.g., utility companies) and federal and state environmental agencies. Despite the fact that available disposal options include the use of high-temperature incineration, disposal efforts have been significantly hampered by the lack of approved incineration facilities. The results of comprehensive PCB incineration programs conducted in accordance with EPA test protocols at each of three high-efficiency boiler sites are presented. Fluemore » gas sampling procedures included the use of both the modified method 5 PCB train and the Source Assessment Sampling System (SASS). Analytical protocols included the use of gas chromatography (GC/ECD) and combined gas chromatography/mass spectrometry (GC/MS). PCB destruction efficiency data for each of nine test runs were in excess of the 99.9% values assumed by the EPA regulation. The cumulative data set lends further credibility to the use of high-efficiency boilers as a viable disposal option for PCB contaminated (50-500 ppm) waste oils when conducted in strict accordance with existing EPA protocols.« less

  3. A Randomized Trial Comparing Mail versus In-Office Distribution of the CAHPS Clinician and Group Survey

    PubMed Central

    Anastario, Michael P; Rodriguez, Hector P; Gallagher, Patricia M; Cleary, Paul D; Shaller, Dale; Rogers, William H; Bogen, Karen; Safran, Dana Gelb

    2010-01-01

    Objective To assess the effect of survey distribution protocol (mail versus handout) on data quality and measurement of patient care experiences. Data Sources/Study Setting Multisite randomized trial of survey distribution protocols. Analytic sample included 2,477 patients of 15 clinicians at three practice sites in New York State. Data Collection/Extraction Methods Mail and handout distribution modes were alternated weekly at each site for 6 weeks. Principal Findings Handout protocols yielded an incomplete distribution rate (74 percent) and lower overall response rates (40 percent versus 58 percent) compared with mail. Handout distribution rates decreased over time and resulted in more favorable survey scores compared with mailed surveys. There were significant mode–physician interaction effects, indicating that data cannot simply be pooled and adjusted for mode. Conclusions In-office survey distribution has the potential to bias measurement and comparison of physicians and sites on patient care experiences. Incomplete distribution rates observed in-office, together with between-office differences in distribution rates and declining rates over time suggest staff may be burdened by the process and selective in their choice of patients. Further testing with a larger physician and site sample is important to definitively establish the potential role for in-office distribution in obtaining reliable, valid assessment of patient care experiences. PMID:20579126

  4. Removal of Giardia spp. and Cryptosporidium spp. from water supply with high turbidity: analytical challenges and perspectives.

    PubMed

    Maciel, P M F; Sabogal-Paz, L P

    2016-06-01

    Giardia and Cryptosporidium species are a serious problem if present in water supplies. The removal of these protozoans and the adaptation of existing protocols are essential for supplying drinking water to developing countries. Considering this, the aim of this study is to evaluate, on a bench level, the removal of Giardia spp. cysts and of Cryptosporidium spp. oocysts from water with high turbidity, using polyaluminium chloride as a coagulant. Filtration using mixed cellulose ester membranes, followed, or not, by purification through immunomagnetic separation (IMS) was used for detecting protozoans. By evaluating the adopted protocol, without using IMS, retrievals of 80% of cysts and 5% of oocysts were obtained, whereas by using IMS, recoveries of 31.5% of cysts and 5.75% of oocysts were reached. When analyzing the coagulant performance, a dosage of 65 mg L(-1) showed contamination from protozoans in all the samples of filtered water. A dosage of 25 mg L(-1) presented protozoans in 50% of the filtered water samples. The results showed an improved performance for the 25 mg L(-1) dosage; therefore, the control of coagulation and adaptation of detection protocols must be evaluated according to the features of raw water and availability of local resources.

  5. Development of a Novel Multipenicillin Assay and Assessment of the Impact of Analyte Degradation: Lessons for Scavenged Sampling in Antimicrobial Pharmacokinetic Study Design.

    PubMed

    Kipper, Karin; Barker, Charlotte I S; Standing, Joseph F; Sharland, Mike; Johnston, Atholl

    2018-01-01

    Penicillins are widely used to treat infections in children; however, the evidence is continuing to evolve in defining the optimal dosing. Modern pediatric pharmacokinetic study protocols frequently favor opportunistic, "scavenged" sampling. This study aimed to develop a small-volume single assay for five major penicillins and to assess the influence of sample degradation on inferences made using pharmacokinetic modeling, to investigate the suitability of scavenged sampling strategies. Using a rapid ultrahigh-performance liquid chromatographic-tandem mass spectrometric method, an assay for five penicillins (amoxicillin, ampicillin, benzylpenicillin, piperacillin, and flucloxacillin) in blood plasma was developed and validated. Penicillin stabilities were evaluated under different conditions. Using these data, the impact of drug degradation on inferences made during pharmacokinetic modeling was evaluated. All evaluated penicillins indicated good stability at room temperature (23 ± 2°C) over 1 h, remaining in the range of 98 to 103% of the original concentration. More-rapid analyte degradation had already occurred after 4 h, with stability ranging from 68% to 99%. Stability over longer periods declined: degradation of up to 60% was observed with delayed sample processing of up to 24 h. Modeling showed that analyte degradation can lead to a 30% and 28% bias in clearance and volume of distribution, respectively, and falsely show nonlinearity in clearance. Five common penicillins can now be measured in a single low-volume blood sample. Beta-lactam chemical instability in plasma can cause misleading pharmacokinetic modeling results, which could impact upon model-based dosing recommendations and the forthcoming era of beta-lactam therapeutic drug monitoring. Copyright © 2017 American Society for Microbiology.

  6. Mainstream Smoke Levels of Volatile Organic Compounds in 50 US Domestic Cigarette Brands Smoked with the ISO and Canadian Intense Protocols

    PubMed Central

    Pazo, Daniel Y.; Moliere, Fallon; Sampson, Maureen M.; Reese, Christopher M.; Agnew-Heard, Kimberly A.; Walters, Matthew J.; Holman, Matthew R.; Blount, Benjamin C.; Watson, Clifford; Chambers, David M.

    2017-01-01

    Introduction A significant portion of the increased risk of cancer and respiratory disease from exposure to cigarette smoke is attributed to volatile organic compounds (VOCs). In this study, 21 VOCs were quantified in mainstream cigarette smoke from 50 U.S. domestic brand varieties that included high market share brands and two Kentucky research cigarettes (3R4F and 1R5F). Methods Mainstream smoke was generated under ISO 3308 and Canadian Intense (CI) smoking protocols with linear smoking machines with a gas sampling bag collection followed by SPME/GC/MS analysis. Results For both protocols, mainstream smoke VOC amounts among the different brand varieties were strongly correlated between the majority of the analytes. Overall, Pearson correlation (r) ranged from 0.68 to 0.99 for ISO and 0.36 to 0.95 for CI. However, monoaromatic compounds were found to increase disproportionately compared to unsaturated, nitro, and carbonyl compounds under the CI smoking protocol where filter ventilation is blocked. Conclusions Overall, machine generated “vapor phase” amounts (μg/cigarette) are primarily attributed to smoking protocol (e.g., blocking of vent holes, puff volume, and puff duration) and filter ventilation. A possible cause for the disproportionate increase in monoaromatic compounds could be increased pyrolysis under low oxygen conditions associated with the CI protocol. PMID:27113015

  7. Development of the Diabetes Technology Society Blood Glucose Monitor System Surveillance Protocol

    PubMed Central

    Klonoff, David C.; Lias, Courtney; Beck, Stayce; Parkes, Joan Lee; Kovatchev, Boris; Vigersky, Robert A.; Arreaza-Rubin, Guillermo; Burk, Robert D.; Kowalski, Aaron; Little, Randie; Nichols, James; Petersen, Matt; Rawlings, Kelly; Sacks, David B.; Sampson, Eric; Scott, Steve; Seley, Jane Jeffrie; Slingerland, Robbert; Vesper, Hubert W.

    2015-01-01

    Background: Inaccurate blood glucsoe monitoring systems (BGMSs) can lead to adverse health effects. The Diabetes Technology Society (DTS) Surveillance Program for cleared BGMSs is intended to protect people with diabetes from inaccurate, unreliable BGMS products that are currently on the market in the United States. The Surveillance Program will provide an independent assessment of the analytical performance of cleared BGMSs. Methods: The DTS BGMS Surveillance Program Steering Committee included experts in glucose monitoring, surveillance testing, and regulatory science. Over one year, the committee engaged in meetings and teleconferences aiming to describe how to conduct BGMS surveillance studies in a scientifically sound manner that is in compliance with good clinical practice and all relevant regulations. Results: A clinical surveillance protocol was created that contains performance targets and analytical accuracy-testing studies with marketed BGMS products conducted by qualified clinical and laboratory sites. This protocol entitled “Protocol for the Diabetes Technology Society Blood Glucose Monitor System Surveillance Program” is attached as supplementary material. Conclusion: This program is needed because currently once a BGMS product has been cleared for use by the FDA, no systematic postmarket Surveillance Program exists that can monitor analytical performance and detect potential problems. This protocol will allow identification of inaccurate and unreliable BGMSs currently available on the US market. The DTS Surveillance Program will provide BGMS manufacturers a benchmark to understand the postmarket analytical performance of their products. Furthermore, patients, health care professionals, payers, and regulatory agencies will be able to use the results of the study to make informed decisions to, respectively, select, prescribe, finance, and regulate BGMSs on the market. PMID:26481642

  8. Development of the Diabetes Technology Society Blood Glucose Monitor System Surveillance Protocol.

    PubMed

    Klonoff, David C; Lias, Courtney; Beck, Stayce; Parkes, Joan Lee; Kovatchev, Boris; Vigersky, Robert A; Arreaza-Rubin, Guillermo; Burk, Robert D; Kowalski, Aaron; Little, Randie; Nichols, James; Petersen, Matt; Rawlings, Kelly; Sacks, David B; Sampson, Eric; Scott, Steve; Seley, Jane Jeffrie; Slingerland, Robbert; Vesper, Hubert W

    2016-05-01

    Inaccurate blood glucsoe monitoring systems (BGMSs) can lead to adverse health effects. The Diabetes Technology Society (DTS) Surveillance Program for cleared BGMSs is intended to protect people with diabetes from inaccurate, unreliable BGMS products that are currently on the market in the United States. The Surveillance Program will provide an independent assessment of the analytical performance of cleared BGMSs. The DTS BGMS Surveillance Program Steering Committee included experts in glucose monitoring, surveillance testing, and regulatory science. Over one year, the committee engaged in meetings and teleconferences aiming to describe how to conduct BGMS surveillance studies in a scientifically sound manner that is in compliance with good clinical practice and all relevant regulations. A clinical surveillance protocol was created that contains performance targets and analytical accuracy-testing studies with marketed BGMS products conducted by qualified clinical and laboratory sites. This protocol entitled "Protocol for the Diabetes Technology Society Blood Glucose Monitor System Surveillance Program" is attached as supplementary material. This program is needed because currently once a BGMS product has been cleared for use by the FDA, no systematic postmarket Surveillance Program exists that can monitor analytical performance and detect potential problems. This protocol will allow identification of inaccurate and unreliable BGMSs currently available on the US market. The DTS Surveillance Program will provide BGMS manufacturers a benchmark to understand the postmarket analytical performance of their products. Furthermore, patients, health care professionals, payers, and regulatory agencies will be able to use the results of the study to make informed decisions to, respectively, select, prescribe, finance, and regulate BGMSs on the market. © 2015 Diabetes Technology Society.

  9. 40 CFR Appendix G to Subpart A of... - UNEP Recommendations for Conditions Applied to Exemption for Essential Laboratory and Analytical...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and laboratory purposes. Pursuant to Decision XI/15 of the Parties to the Montreal Protocol, effective... laboratory and analytical purposes is authorized provided that these laboratory and analytical chemicals..., restricted to laboratory use and analytical purposes and specifying that used or surplus substances should be...

  10. 40 CFR Appendix G to Subpart A of... - UNEP Recommendations for Conditions Applied to Exemption for Essential Laboratory and Analytical...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and laboratory purposes. Pursuant to Decision XI/15 of the Parties to the Montreal Protocol, effective... laboratory and analytical purposes is authorized provided that these laboratory and analytical chemicals..., restricted to laboratory use and analytical purposes and specifying that used or surplus substances should be...

  11. 40 CFR Appendix G to Subpart A of... - UNEP Recommendations for Conditions Applied to Exemption for Essential Laboratory and Analytical...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and laboratory purposes. Pursuant to Decision XI/15 of the Parties to the Montreal Protocol, effective... laboratory and analytical purposes is authorized provided that these laboratory and analytical chemicals..., restricted to laboratory use and analytical purposes and specifying that used or surplus substances should be...

  12. 40 CFR Appendix G to Subpart A of... - UNEP Recommendations for Conditions Applied to Exemption for Essential Laboratory and Analytical...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and laboratory purposes. Pursuant to Decision XI/15 of the Parties to the Montreal Protocol, effective... laboratory and analytical purposes is authorized provided that these laboratory and analytical chemicals..., restricted to laboratory use and analytical purposes and specifying that used or surplus substances should be...

  13. 40 CFR Appendix G to Subpart A of... - UNEP Recommendations for Conditions Applied to Exemption for Essential Laboratory and Analytical...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and laboratory purposes. Pursuant to Decision XI/15 of the Parties to the Montreal Protocol, effective... laboratory and analytical purposes is authorized provided that these laboratory and analytical chemicals..., restricted to laboratory use and analytical purposes and specifying that used or surplus substances should be...

  14. Optimal molecular profiling of tissue and tissue components: defining the best processing and microdissection methods for biomedical applications.

    PubMed

    Bova, G Steven; Eltoum, Isam A; Kiernan, John A; Siegal, Gene P; Frost, Andra R; Best, Carolyn J M; Gillespie, John W; Su, Gloria H; Emmert-Buck, Michael R

    2005-02-01

    Isolation of well-preserved pure cell populations is a prerequisite for sound studies of the molecular basis of any tissue-based biological phenomenon. This article reviews current methods for obtaining anatomically specific signals from molecules isolated from tissues, a basic requirement for productive linking of phenotype and genotype. The quality of samples isolated from tissue and used for molecular analysis is often glossed over or omitted from publications, making interpretation and replication of data difficult or impossible. Fortunately, recently developed techniques allow life scientists to better document and control the quality of samples used for a given assay, creating a foundation for improvement in this area. Tissue processing for molecular studies usually involves some or all of the following steps: tissue collection, gross dissection/identification, fixation, processing/embedding, storage/archiving, sectioning, staining, microdissection/annotation, and pure analyte labeling/identification and quantification. We provide a detailed comparison of some current tissue microdissection technologies, and provide detailed example protocols for tissue component handling upstream and downstream from microdissection. We also discuss some of the physical and chemical issues related to optimal tissue processing, and include methods specific to cytology specimens. We encourage each laboratory to use these as a starting point for optimization of their overall process of moving from collected tissue to high quality, appropriately anatomically tagged scientific results. In optimized protocols is a source of inefficiency in current life science research. Improvement in this area will significantly increase life science quality and productivity. The article is divided into introduction, materials, protocols, and notes sections. Because many protocols are covered in each of these sections, information relating to a single protocol is not contiguous. To get the greatest benefit from this article, readers are advised to read through the entire article first, identify protocols appropriate to their laboratory for each step in their workflow, and then reread entries in each section pertaining to each of these single protocols.

  15. History and progress of the North American Soil Geochemical Landscapes Project, 2001-2010

    USGS Publications Warehouse

    Smith, David B.; Cannon, William F.; Woodruff, Laurel G.; Rivera, Francisco Moreira; Rencz, Andrew N.; Garrett, Robert G.

    2012-01-01

    In 2007, the U.S. Geological Survey, the Geological Survey of Canada, and the Mexican Geological Survey initiated a low-density (1 site per 1600 km2, 13323 sites) geochemical and mineralogical survey of North American soils (North American Soil Geochemical Landscapes Project). Sampling and analytical protocols were developed at a series of workshops in 20032004 and pilot studies were conducted from 20042007. The ideal sampling protocol at each site includes a sample from 05 cm depth, a composite of the soil A horizon, and a sample from the soil C horizon. The 3, HClO4, and HF. Separate methods are used for As, Hg, Se, and total C on this same size fraction. The major mineralogical components are determined by a quantitative X-ray diffraction method. Sampling in the conterminous U.S. was completed in 2010 (c. 4800 sites) with chemical and mineralogical analysis currently underway. In Mexico, approximately 66% of the sampling (871 sites) had been done by the end of 2010 with completion expected in 2012. After completing sampling in the Maritime provinces and portions of other provinces (472 sites, 7.6% of the total), Canada withdrew from the project in 2010. Preliminary results for a swath from the central U.S. to Florida clearly show the effects of soil parent material and climate on the chemical and mineralogical composition of soils. A sample archive will be established and made available for future investigations.

  16. Validation of the LacTek test applied to spiked extracts of tissue samples: determination of performance characteristics.

    PubMed

    Mitchell, J M; Yee, A J; McNab, W B; Griffiths, M W; McEwen, S A

    1999-01-01

    LacTek tests are competitive enzyme-linked immunosorbent assays intended for rapid detection of antimicrobial residues in bovine milk. In this study, the LacTek test protocol was modified for use with extracts of bovine tissue to detect beta-lactam, tetracycline, and sulfamethazine residues. Test performance characteristics--precision, accuracy, ruggedness, practicability, and analytical specificity and sensitivity--were investigated. Results suggest that LacTek tests can be easily adapted to detect antimicrobial residues in extracts of lean ground beef. However, positive samples may not contain residues at violative concentrations (i.e., Canadian maximum residue limits), and therefore, additional analysis would be required for final confirmation and quantitation (e.g., chromatography).

  17. Bioanalytical challenge: A review of environmental and pharmaceuticals contaminants in human milk.

    PubMed

    Lopes, Bianca Rebelo; Barreiro, Juliana Cristina; Cass, Quezia Bezerra

    2016-10-25

    An overview of bioanalytical methods for the determination of environmental and pharmaceutical contaminants in human milk is presented. The exposure of children to these contaminants through lactation has been widely investigated. The human milk contains diverse proteins, lipids, and carbohydrates and the concentration of these components is drastically altered during the lactation period providing a high degree of an analytical challenge. Sample collection and pretreatment are still considered the Achilles' heel. This review presents liquid chromatographic methods developed in the last 10 years for this complex matrix with focuses in the extraction and quantification steps. Green sample preparation protocols have been emphasized. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Automated Desalting Apparatus

    NASA Technical Reports Server (NTRS)

    Spencer, Maegan K.; Liu, De-Ling; Kanik, Isik; Beegle, Luther

    2010-01-01

    Because salt and metals can mask the signature of a variety of organic molecules (like amino acids) in any given sample, an automated system to purify complex field samples has been created for the analytical techniques of electrospray ionization/ mass spectroscopy (ESI/MS), capillary electrophoresis (CE), and biological assays where unique identification requires at least some processing of complex samples. This development allows for automated sample preparation in the laboratory and analysis of complex samples in the field with multiple types of analytical instruments. Rather than using tedious, exacting protocols for desalting samples by hand, this innovation, called the Automated Sample Processing System (ASPS), takes analytes that have been extracted through high-temperature solvent extraction and introduces them into the desalting column. After 20 minutes, the eluent is produced. This clear liquid can then be directly analyzed by the techniques listed above. The current apparatus including the computer and power supplies is sturdy, has an approximate mass of 10 kg, and a volume of about 20 20 20 cm, and is undergoing further miniaturization. This system currently targets amino acids. For these molecules, a slurry of 1 g cation exchange resin in deionized water is packed into a column of the apparatus. Initial generation of the resin is done by flowing sequentially 2.3 bed volumes of 2N NaOH and 2N HCl (1 mL each) to rinse the resin, followed by .5 mL of deionized water. This makes the pH of the resin near neutral, and eliminates cross sample contamination. Afterward, 2.3 mL of extracted sample is then loaded into the column onto the top of the resin bed. Because the column is packed tightly, the sample can be applied without disturbing the resin bed. This is a vital step needed to ensure that the analytes adhere to the resin. After the sample is drained, oxalic acid (1 mL, pH 1.6-1.8, adjusted with NH4OH) is pumped into the column. Oxalic acid works as a chelating reagent to bring out metal ions, such as calcium and iron, which would otherwise interfere with amino acid analysis. After oxalic acid, 1 mL 0.01 N HCl and 1 mL deionized water is used to sequentially rinse the resin. Finally, the amino acids attached to the resin, and the analytes are eluted using 2.5 M NH4OH (1 mL), and the NH4OH eluent is collected in a vial for analysis.

  19. Sample preparation and EFTEM of Meat Samples for Nanoparticle Analysis in Food

    NASA Astrophysics Data System (ADS)

    Lari, L.; Dudkiewicz, A.

    2014-06-01

    Nanoparticles are used in industry for personal care products and the preparation of food. In the latter application, their functions include the prevention of microbes' growth, increase of the foods nutritional value and sensory quality. EU regulations require a risk assessment of the nanoparticles used in foods and food contact materials before the products can reach the market. However, availability of validated analytical methodologies for detection and characterisation of the nanoparticles in food hampers appropriate risk assessment. As part of a research on the evaluation of the methods for screening and quantification of Ag nanoparticles in meat we have tested a new TEM sample preparation alternative to resin embedding and cryo-sectioning. Energy filtered TEM analysis was applied to evaluate thickness and the uniformity of thin meat layers acquired at increasing input of the sample demonstrating that the protocols used ensured good stability under the electron beam, reliable sample concentration and reproducibility.

  20. Semiautomated Device for Batch Extraction of Metabolites from Tissue Samples

    PubMed Central

    2012-01-01

    Metabolomics has become a mainstream analytical strategy for investigating metabolism. The quality of data derived from these studies is proportional to the consistency of the sample preparation. Although considerable research has been devoted to finding optimal extraction protocols, most of the established methods require extensive sample handling. Manual sample preparation can be highly effective in the hands of skilled technicians, but an automated tool for purifying metabolites from complex biological tissues would be of obvious utility to the field. Here, we introduce the semiautomated metabolite batch extraction device (SAMBED), a new tool designed to simplify metabolomics sample preparation. We discuss SAMBED’s design and show that SAMBED-based extractions are of comparable quality to extracts produced through traditional methods (13% mean coefficient of variation from SAMBED versus 16% from manual extractions). Moreover, we show that aqueous SAMBED-based methods can be completed in less than a quarter of the time required for manual extractions. PMID:22292466

  1. Metabolomic analysis-Addressing NMR and LC-MS related problems in human feces sample preparation.

    PubMed

    Moosmang, Simon; Pitscheider, Maria; Sturm, Sonja; Seger, Christoph; Tilg, Herbert; Halabalaki, Maria; Stuppner, Hermann

    2017-10-31

    Metabolomics is a well-established field in fundamental clinical research with applications in different human body fluids. However, metabolomic investigations in feces are currently an emerging field. Fecal sample preparation is a demanding task due to high complexity and heterogeneity of the matrix. To gain access to the information enclosed in human feces it is necessary to extract the metabolites and make them accessible to analytical platforms like NMR or LC-MS. In this study different pre-analytical parameters and factors were investigated i.e. water content, different extraction solvents, influence of freeze-drying and homogenization, ratios of sample weight to extraction solvent, and their respective impact on metabolite profiles acquired by NMR and LC-MS. The results indicate that profiles are strongly biased by selection of extraction solvent or drying of samples, which causes different metabolites to be lost, under- or overstated. Additionally signal intensity and reproducibility of the measurement were found to be strongly dependent on sample pre-treatment steps: freeze-drying and homogenization lead to improved release of metabolites and thus increased signals, but at the same time induced variations and thus deteriorated reproducibility. We established the first protocol for extraction of human fecal samples and subsequent measurement with both complementary techniques NMR and LC-MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Strategies for Distinguishing Abiotic Chemistry from Martian Biochemistry in Samples Returned from Mars

    NASA Technical Reports Server (NTRS)

    Glavin, D. P.; Burton, A. S.; Callahan, M. P.; Elsila, J. E.; Stern, J. C.; Dworkin, J. P.

    2012-01-01

    A key goal in the search for evidence of extinct or extant life on Mars will be the identification of chemical biosignatures including complex organic molecules common to all life on Earth. These include amino acids, the monomer building blocks of proteins and enzymes, and nucleobases, which serve as the structural basis of information storage in DNA and RNA. However, many of these organic compounds can also be formed abiotically as demonstrated by their prevalence in carbonaceous meteorites [1]. Therefore, an important challenge in the search for evidence of life on Mars will be distinguishing between abiotic chemistry of either meteoritic or martian origin from any chemical biosignatures from an extinct or extant martian biota. Although current robotic missions to Mars, including the 2011 Mars Science Laboratory (MSL) and the planned 2018 ExoMars rovers, will have the analytical capability needed to identify these key classes of organic molecules if present [2,3], return of a diverse suite of martian samples to Earth would allow for much more intensive laboratory studies using a broad array of extraction protocols and state-of-theart analytical techniques for bulk and spatially resolved characterization, molecular detection, and isotopic and enantiomeric compositions that may be required for unambiguous confirmation of martian life. Here we will describe current state-of-the-art laboratory analytical techniques that have been used to characterize the abundance and distribution of amino acids and nucleobases in meteorites, Apollo samples, and comet- exposed materials returned by the Stardust mission with an emphasis on their molecular characteristics that can be used to distinguish abiotic chemistry from biochemistry as we know it. The study of organic compounds in carbonaceous meteorites is highly relevant to Mars sample return analysis, since exogenous organic matter should have accumulated in the martian regolith over the last several billion years and the analytical techniques previously developed for the study of extraterrestrial materials can be applied to martian samples.

  3. An integrated platform for directly widely-targeted quantitative analysis of feces part I: Platform configuration and method validation.

    PubMed

    Song, Yuelin; Song, Qingqing; Li, Jun; Zheng, Jiao; Li, Chun; Zhang, Yuan; Zhang, Lingling; Jiang, Yong; Tu, Pengfei

    2016-07-08

    Direct analysis is of great importance to understand the real chemical profile of a given sample, notably biological materials, because either chemical degradation or diverse errors and uncertainties might be resulted from sophisticated protocols. In comparison with biofluids, it is still challenging for direct analysis of solid biological samples using high performance liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Herein, a new analytical platform was configured by online hyphenating pressurized liquid extraction (PLE), turbulent flow chromatography (TFC), and LC-MS/MS. A facile, but robust PLE module was constructed based on the phenomenon that noticeable back-pressure can be generated during rapid fluid passing through a narrow tube. TFC column that is advantageous at extracting low molecular analytes from rushing fluid was employed to link at the outlet of the PLE module to capture constituents-of-interest. An electronic 6-port/2-position valve was introduced between TFC column and LC-MS/MS to fragment each measurement into extraction and elution phases, whereas LC-MS/MS took the charge of analyte separation and monitoring. As a proof of concept, simultaneous determination of 24 endogenous substances including eighteen steroids, five eicosanoids, and one porphyrin in feces was carried out in this paper. Method validation assays demonstrated the analytical platform to be qualified for directly simultaneous measurement of diverse endogenous analytes in fecal matrices. Application of this integrated platform on homolog-focused profiling of feces is discussed in a companion paper. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. A "three-in-one" sample preparation method for simultaneous determination of B-group water-soluble vitamins in infant formula using VitaFast(®) kits.

    PubMed

    Zhang, Heng; Lan, Fang; Shi, Yupeng; Wan, Zhi-Gang; Yue, Zhen-Feng; Fan, Fang; Lin, Yan-Kui; Tang, Mu-Jin; Lv, Jing-Zhang; Xiao, Tan; Yi, Changqing

    2014-06-15

    VitaFast(®) test kits designed for the microbiological assay in microtiter plate format can be applied to quantitative determination of B-group water-soluble vitamins such as vitamin B12, folic acid and biotin, et al. Compared to traditional microbiological methods, VitaFast(®) kits significantly reduce sample processing time and provide greater reliability, higher productivity and better accuracy. Recently, simultaneous determination of vitamin B12, folic acid and biotin in one sample is urgently required when evaluating the quality of infant formulae in our practical work. However, the present sample preparation protocols which are developed for individual test systems, are incompatible with simultaneous determination of several analytes. To solve this problem, a novel "three-in-one" sample preparation method is herein developed for simultaneous determination of B-group water-soluble vitamins using VitaFast(®) kits. The performance of this novel "three-in-one" sample preparation method was systematically evaluated through comparing with individual sample preparation protocols. The experimental results of the assays which employed "three-in-one" sample preparation method were in good agreement with those obtained from conventional VitaFast(®) extraction methods, indicating that the proposed "three-in-one" sample preparation method is applicable to the present three VitaFast(®) vitamin test systems, thus offering a promising alternative for the three independent sample preparation methods. The proposed new sample preparation method will significantly improve the efficiency of infant formulae inspection. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Big data analytics : predicting traffic flow regimes from simulated connected vehicle messages using data analytics and machine learning.

    DOT National Transportation Integrated Search

    2016-12-25

    The key objectives of this study were to: 1. Develop advanced analytical techniques that make use of a dynamically configurable connected vehicle message protocol to predict traffic flow regimes in near-real time in a virtual environment and examine ...

  6. Development of a fast and simple gas chromatographic protocol based on the combined use of alkyl chloroformate and solid phase microextraction for the assay of polyamines in human urine.

    PubMed

    Naccarato, Attilio; Elliani, Rosangela; Cavaliere, Brunella; Sindona, Giovanni; Tagarelli, Antonio

    2018-05-11

    Polyamines are aliphatic amines with low molecular weight that are widely recognized as one of the most important cancer biomarkers for early diagnosis and treatment. The goal of the work herein presented is the development of a rapid and simple method for the quantification of free polyamines (i.e., putrescine, cadaverine, spermidine, spermine) and N-monoacetylated polyamines (i.e., N 1 -Acetylspermidine, N 8 -Acetylspermidine, and N 1 -Acetylspermine) in human urine. A preliminary derivatization with propyl chloroformate combined with the use of solid phase microextraction (SPME) allowed for an easy and automatable protocol involving minimal sample handling and no consumption of organic solvents. The affinity of the analytes toward five commercial SPME coatings was evaluated in univariate mode, and the best result in terms of analyte extraction was achieved using the divinylbenzene/carboxen/polydimethylsiloxane fiber. The variables affecting the performance of SPME analysis were optimized by the multivariate approach of experimental design and, in particular, using a central composite design (CCD). The optimal working conditions in terms of response values are the following: extraction temperature 40 °C, extraction time of 15 min and no addition of NaCl. Analyses were carried out by gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) in selected reaction monitoring (SRM) acquisition mode. The developed method was validated according to the guidelines issued by the Food and Drug Administration (FDA). The satisfactory performances reached in terms of linearity, sensitivity (LOQs between 0.01 and 0.1 μg/mL), matrix effect (68-121%), accuracy, and precision (inter-day values between -24% and +16% and in the range 3.3-28.4%, respectively) make the proposed protocol suitable to be adopted for quantification of these important biomarkers in urine samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. A Protocol Layer Trust-Based Intrusion Detection Scheme for Wireless Sensor Networks

    PubMed Central

    Wang, Jian; Jiang, Shuai; Fapojuwo, Abraham O.

    2017-01-01

    This article proposes a protocol layer trust-based intrusion detection scheme for wireless sensor networks. Unlike existing work, the trust value of a sensor node is evaluated according to the deviations of key parameters at each protocol layer considering the attacks initiated at different protocol layers will inevitably have impacts on the parameters of the corresponding protocol layers. For simplicity, the paper mainly considers three aspects of trustworthiness, namely physical layer trust, media access control layer trust and network layer trust. The per-layer trust metrics are then combined to determine the overall trust metric of a sensor node. The performance of the proposed intrusion detection mechanism is then analyzed using the t-distribution to derive analytical results of false positive and false negative probabilities. Numerical analytical results, validated by simulation results, are presented in different attack scenarios. It is shown that the proposed protocol layer trust-based intrusion detection scheme outperforms a state-of-the-art scheme in terms of detection probability and false probability, demonstrating its usefulness for detecting cross-layer attacks. PMID:28555023

  8. A Protocol Layer Trust-Based Intrusion Detection Scheme for Wireless Sensor Networks.

    PubMed

    Wang, Jian; Jiang, Shuai; Fapojuwo, Abraham O

    2017-05-27

    This article proposes a protocol layer trust-based intrusion detection scheme for wireless sensor networks. Unlike existing work, the trust value of a sensor node is evaluated according to the deviations of key parameters at each protocol layer considering the attacks initiated at different protocol layers will inevitably have impacts on the parameters of the corresponding protocol layers. For simplicity, the paper mainly considers three aspects of trustworthiness, namely physical layer trust, media access control layer trust and network layer trust. The per-layer trust metrics are then combined to determine the overall trust metric of a sensor node. The performance of the proposed intrusion detection mechanism is then analyzed using the t-distribution to derive analytical results of false positive and false negative probabilities. Numerical analytical results, validated by simulation results, are presented in different attack scenarios. It is shown that the proposed protocol layer trust-based intrusion detection scheme outperforms a state-of-the-art scheme in terms of detection probability and false probability, demonstrating its usefulness for detecting cross-layer attacks.

  9. Bias from two analytical laboratories involved in a long-term air monitoring program measuring organic pollutants in the Arctic: a quality assurance/quality control assessment.

    PubMed

    Su, Yushan; Hung, Hayley; Stern, Gary; Sverko, Ed; Lao, Randy; Barresi, Enzo; Rosenberg, Bruno; Fellin, Phil; Li, Henrik; Xiao, Hang

    2011-11-01

    Initiated in 1992, air monitoring of organic pollutants in the Canadian Arctic provided spatial and temporal trends in support of Canada's participation in the Stockholm Convention of Persistent Organic Pollutants. The specific analytical laboratory charged with this task was changed in 2002 while field sampling protocols remained unchanged. Three rounds of intensive comparison studies were conducted in 2004, 2005, and 2008 to assess data comparability between the two laboratories. Analysis was compared for organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs) in standards, blind samples of mixed standards and extracts of real air samples. Good measurement accuracy was achieved for both laboratories when standards were analyzed. Variation of measurement accuracy over time was found for some OCPs and PCBs in standards on a random and non-systematic manner. Relatively low accuracy in analyzing blind samples was likely related to the process of sample purification. Inter-laboratory measurement differences for standards (<30%) and samples (<70%) were generally less than or comparable to those reported in a previous inter-laboratory study with 21 participating laboratories. Regression analysis showed inconsistent data comparability between the two laboratories during the initial stages of the study. These inter-laboratory differences can complicate abilities to discern long-term trends of pollutants in a given sampling site. It is advisable to maintain long-term measurements with minimal changes in sample analysis.

  10. GC-MS analyses of the volatiles of Houttuynia cordata Thunb.

    PubMed

    Yang, Zhan-Nan; Luo, Shi-Qiong; Ma, Jing; Wu, Dan; Hong, Liang; Yu, Zheng-Wen

    2016-09-01

    GC-MS is the basis of analysis of plant volatiles. Several protocols employed for the assay have resulted in inconsistent results in the literature. We developed a GC-MS method, which were applied to analyze 25 volatiles (α-pinene, camphene, β-pinene, 2-methyl-2-pentenal, myrcene, (+)-limonene, eucalyptol, trans-2-hexenal, γ-terpinene, cis-3-hexeneyl-acetate, 1-hexanol, α-pinene oxide, cis-3-hexen-1-ol, trans-2-hexen-1-ol, decanal, linalool, acetyl-borneol, β-caryophyllene, 2-undecanone, 4-terpineol, borneol, decanol, eugenol, isophytol and phytol) of Houttuynia cordata Thunb. Linear behaviors for all analytes were observed with a linear regression relationship (r2>0.9991) at the concentrations tested. Recoveries of the 25 analytes were 98.56-103.77% with RSDs <3.0%. Solution extraction (SE), which involved addition of an internal standard, could avoid errors for factors in sample preparation by steam distillation (SD) and solidphase micro extraction (SPME). Less sample material (≍0.05g fresh leaves of H. cordata) could be used to determine the contents of 25 analytes by our proposed method and, after collection, did not affect the normal physiological activity or growth of H. cordata. This method can be used to monitor the metabolic accumulation of H. cordata volatiles.

  11. Automated sample preparation using membrane microtiter extraction for bioanalytical mass spectrometry.

    PubMed

    Janiszewski, J; Schneider, P; Hoffmaster, K; Swyden, M; Wells, D; Fouda, H

    1997-01-01

    The development and application of membrane solid phase extraction (SPE) in 96-well microtiter plate format is described for the automated analysis of drugs in biological fluids. The small bed volume of the membrane allows elution of the analyte in a very small solvent volume, permitting direct HPLC injection and negating the need for the time consuming solvent evaporation step. A programmable liquid handling station (Quadra 96) was modified to automate all SPE steps. To avoid drying of the SPE bed and to enhance the analytical precision a novel protocol for performing the condition, load and wash steps in rapid succession was utilized. A block of 96 samples can now be extracted in 10 min., about 30 times faster than manual solvent extraction or single cartridge SPE methods. This processing speed complements the high-throughput speed of contemporary high performance liquid chromatography mass spectrometry (HPLC/MS) analysis. The quantitative analysis of a test analyte (Ziprasidone) in plasma demonstrates the utility and throughput of membrane SPE in combination with HPLC/MS. The results obtained with the current automated procedure compare favorably with those obtained using solvent and traditional solid phase extraction methods. The method has been used for the analysis of numerous drug prototypes in biological fluids to support drug discovery efforts.

  12. Improved online δ18O measurements of nitrogen- and sulfur-bearing organic materials and a proposed analytical protocol

    USGS Publications Warehouse

    Qi, H.; Coplen, T.B.; Wassenaar, L.I.

    2011-01-01

    It is well known that N2 in the ion source of a mass spectrometer interferes with the CO background during the δ18O measurement of carbon monoxide. A similar problem arises with the high-temperature conversion (HTC) analysis of nitrogenous O-bearing samples (e.g. nitrates and keratins) to CO for δ18O measurement, where the sample introduces a significant N2 peak before the CO peak, making determination of accurate oxygen isotope ratios difficult. Although using a gas chromatography (GC) column longer than that commonly provided by manufacturers (0.6 m) can improve the efficiency of separation of CO and N2 and using a valve to divert nitrogen and prevent it from entering the ion source of a mass spectrometer improved measurement results, biased δ18O values could still be obtained. A careful evaluation of the performance of the GC separation column was carried out. With optimal GC columns, the δ18O reproducibility of human hair keratins and other keratin materials was better than ±0.15 ‰ (n = 5; for the internal analytical reproducibility), and better than ±0.10 ‰ (n = 4; for the external analytical reproducibility).

  13. Comparing rapid methods for detecting Listeria in seafood and environmental samples using the most probably number (MPN) technique.

    PubMed

    Cruz, Cristina D; Win, Jessicah K; Chantarachoti, Jiraporn; Mutukumira, Anthony N; Fletcher, Graham C

    2012-02-15

    The standard Bacteriological Analytical Manual (BAM) protocol for detecting Listeria in food and on environmental surfaces takes about 96 h. Some studies indicate that rapid methods, which produce results within 48 h, may be as sensitive and accurate as the culture protocol. As they only give presence/absence results, it can be difficult to compare the accuracy of results generated. We used the Most Probable Number (MPN) technique to evaluate the performance and detection limits of six rapid kits for detecting Listeria in seafood and on an environmental surface compared with the standard protocol. Three seafood products and an environmental surface were inoculated with similar known cell concentrations of Listeria and analyzed according to the manufacturers' instructions. The MPN was estimated using the MPN-BAM spreadsheet. For the seafood products no differences were observed among the rapid kits and efficiency was similar to the BAM method. On the environmental surface the BAM protocol had a higher recovery rate (sensitivity) than any of the rapid kits tested. Clearview™, Reveal®, TECRA® and VIDAS® LDUO detected the cells but only at high concentrations (>10(2) CFU/10 cm(2)). Two kits (VIP™ and Petrifilm™) failed to detect 10(4) CFU/10 cm(2). The MPN method was a useful tool for comparing the results generated by these presence/absence test kits. There remains a need to develop a rapid and sensitive method for detecting Listeria in environmental samples that performs as well as the BAM protocol, since none of the rapid tests used in this study achieved a satisfactory result. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Comparison of Gluten Extraction Protocols Assessed by LC-MS/MS Analysis.

    PubMed

    Fallahbaghery, Azadeh; Zou, Wei; Byrne, Keren; Howitt, Crispin A; Colgrave, Michelle L

    2017-04-05

    The efficiency of gluten extraction is of critical importance to the results derived from any analytical method for gluten detection and quantitation, whether it employs reagent-based technology (antibodies) or analytical instrumentation (mass spectrometry). If the target proteins are not efficiently extracted, the end result will be an under-estimation in the gluten content posing a health risk to people affected by conditions such as celiac disease (CD) and nonceliac gluten sensitivity (NCGS). Five different extraction protocols were investigated using LC-MRM-MS for their ability to efficiently and reproducibly extract gluten. The rapid and simple "IPA/DTT" protocol and related "two-step" protocol were enriched for gluten proteins, 55/86% (trypsin/chymotrypsin) and 41/68% of all protein identifications, respectively, with both methods showing high reproducibility (CV < 15%). When using multistep protocols, it was critical to examine all fractions, as coextraction of proteins occurred across fractions, with significant levels of proteins existing in unexpected fractions and not all proteins within a particular gluten class behaving the same.

  15. Rapid identification of regulated organic chemical compounds in toys using ambient ionization and a miniature mass spectrometry system.

    PubMed

    Guo, Xiangyu; Bai, Hua; Lv, Yueguang; Xi, Guangcheng; Li, Junfang; Ma, Xiaoxiao; Ren, Yue; Ouyang, Zheng; Ma, Qiang

    2018-04-01

    Rapid, on-site analysis was achieved through significantly simplified operation procedures for a wide variety of toy samples (crayon, temporary tattoo sticker, finger paint, modeling clay, and bubble solution) using a miniature mass spectrometry system with ambient ionization capability. The labor-intensive analytical protocols involving sample workup and chemical separation, traditionally required for MS-based analysis, were replaced by direct sampling analysis using ambient ionization methods. A Mini β ion trap miniature mass spectrometer was coupled with versatile ambient ionization methods, e.g. paper spray, extraction spray and slug-flow microextraction nanoESI for direct identification of prohibited colorants, carcinogenic primary aromatic amines, allergenic fragrances, preservatives and plasticizers from raw toy samples. The use of paper substrates coated with Co 3 O 4 nanoparticles allowed a great increase in sensitivity for paper spray. Limits of detection as low as 5μgkg -1 were obtained for target analytes. The methods being developed based on the integration of ambient ionization with miniature mass spectrometer represent alternatives to current in-lab MS analysis operation, and would enable fast, outside-the-lab screening of toy products to ensure children's safety and health. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. High-Precision In Situ 87Sr/86Sr Analyses through Microsampling on Solid Samples: Applications to Earth and Life Sciences

    PubMed Central

    Di Salvo, Sara; Casalini, Martina; Marchionni, Sara; Adani, Teresa; Ulivi, Maurizio; Tommasini, Simone; Avanzinelli, Riccardo; Mazza, Paul P. A.; Francalanci, Lorella

    2018-01-01

    An analytical protocol for high-precision, in situ microscale isotopic investigations is presented here, which combines the use of a high-performing mechanical microsampling device and high-precision TIMS measurements on micro-Sr samples, allowing for excellent results both in accuracy and precision. The present paper is a detailed methodological description of the whole analytical procedure from sampling to elemental purification and Sr-isotope measurements. The method offers the potential to attain isotope data at the microscale on a wide range of solid materials with the use of minimally invasive sampling. In addition, we present three significant case studies for geological and life sciences, as examples of the various applications of microscale 87Sr/86Sr isotope ratios, concerning (i) the pre-eruptive mechanisms triggering recent eruptions at Nisyros volcano (Greece), (ii) the dynamics involved with the initial magma ascent during Eyjafjallajökull volcano's (Iceland) 2010 eruption, which are usually related to the precursory signals of the eruption, and (iii) the environmental context of a MIS 3 cave bear, Ursus spelaeus. The studied cases show the robustness of the methods, which can be also be applied in other areas, such as cultural heritage, archaeology, petrology, and forensic sciences. PMID:29850369

  17. Forensic electrochemistry: indirect electrochemical sensing of the components of the new psychoactive substance "Synthacaine".

    PubMed

    Cumba, Loanda R; Kolliopoulos, Athanasios V; Smith, Jamie P; Thompson, Paul D; Evans, Peter R; Sutcliffe, Oliver B; do Carmo, Devaney R; Banks, Craig E

    2015-08-21

    "Synthacaine" is a New Psychoactive Substance which is, due to its inherent psychoactive properties, reported to imitate the effects of cocaine and is therefore consequently branded as "legal cocaine". The only analytical approach reported to date for the sensing of "Synthacaine" is mass spectrometry. In this paper, we explore and evaluate a range of potential analytical techniques for its quantification and potential use in the field screening "Synthacaine" using Raman spectroscopy, presumptive (colour) testing, High Performance Liquid Chromatography (HPLC) and electrochemistry. HPLC analysis of street samples reveals that "Synthacaine" comprises a mixture of methiopropamine (MPA) and 2-aminoindane (2-AI). Raman spectroscopy and presumptive (colour) tests, the Marquis, Mandelin, Simon's and Robadope test, are evaluated towards a potential in-the-field screening approach but are found to not be able to discriminate between the two when they are both present in the same sample, as is the case in the real street samples. We report for the first time a novel indirect electrochemical protocol for the sensing of MPA and 2-AI which is independently validated in street samples with HPLC. This novel electrochemical approach based upon one-shot disposable cost effective screen-printed graphite macroelectrodes holds potential for in-the-field screening for "Synthacaine".

  18. Determination of refractive and volatile elements in sediment using laser ablation inductively coupled plasma mass spectrometry.

    PubMed

    Duodu, Godfred Odame; Goonetilleke, Ashantha; Allen, Charlotte; Ayoko, Godwin A

    2015-10-22

    Wet-milling protocol was employed to produce pressed powder tablets with excellent cohesion and homogeneity suitable for laser ablation (LA) analysis of volatile and refractive elements in sediment. The influence of sample preparation on analytical performance was also investigated, including sample homogeneity, accuracy and limit of detection. Milling in volatile solvent for 40 min ensured sample is well mixed and could reasonably recover both volatile (Hg) and refractive (Zr) elements. With the exception of Cr (-52%) and Nb (+26%) major, minor and trace elements in STSD-1 and MESS-3 could be analysed within ±20% of the certified values. Comparison of the method with total digestion method using HF was tested by analysing 10 different sediment samples. The laser method recovers significantly higher amounts of analytes such as Ag, Cd, Sn and Sn than the total digestion method making it a more robust method for elements across the periodic table. LA-ICP-MS also eliminates the interferences from chemical reagents as well as the health and safety risks associated with digestion processes. Therefore, it can be considered as an enhanced method for the analysis of heterogeneous matrices such as river sediments. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites.

    PubMed

    Xie, Li; Chen, Liqin; Gu, Pan; Wei, Lanlan; Kang, Xuejun

    2018-03-01

    The extraction and analysis of catecholamine neurotransmitters in biological fluids is of great importance in assessing nervous system function and related diseases, but their precise measurement is still a challenge. Many protocols have been described for neurotransmitter measurement by a variety of instruments, including high-pressure liquid chromatography (HPLC). However, there are shortcomings, such as complicated operation or hard-to-detect multiple targets, which cannot be avoided, and presently, the dominant analysis technique is still HPLC coupled with sensitive electrochemical or fluorimetric detection, due to its high sensitivity and good selectivity. Here, a detailed protocol is described for the pretreatment and detection of catecholamines with high pressure liquid chromatography with electrochemical detection (HPLC-ECD) in real urine samples of infants, using electrospun composite nanofibers composed of polymeric crown ether with polystyrene as adsorbent, also known as the packed-fiber solid phase extraction (PFSPE) method. We show how urine samples can be easily precleaned by a nanofiber-packed solid phase column, and how the analytes in the sample can be rapidly enriched, desorbed, and detected on an ECD system. PFSPE greatly simplifies the pretreatment procedures for biological samples, allowing for decreased time, expense, and reduction of the loss of targets. Overall, this work illustrates a simple and convenient protocol for solid-phase extraction coupled to an HPLC-ECD system for simultaneous determination of three monoamine neurotransmitters (norepinephrine (NE), epinephrine (E), dopamine (DA)) and two of their metabolites (3-methoxy-4-hydroxyphenylglycol (MHPG) and 3,4-dihydroxy-phenylacetic acid (DOPAC)) in infants' urine. The established protocol was applied to assess the differences of urinary catecholamines and their metabolites between high-risk infants with perinatal brain damage and healthy controls. Comparative analysis revealed a significant difference in urinary MHPG between the two groups, indicating that the catecholamine metabolites may be an important candidate marker for early diagnosis of cases at risk for brain damage in infants.

  20. A communal catalogue reveals Earth’s multiscale microbial diversity

    DOE PAGES

    Thompson, Luke R.; Sanders, Jon G.; McDonald, Daniel; ...

    2017-11-01

    Our growing awareness of the importance and diversity of the microbial world contrasts starkly with our limited understanding of its fundamental structure. Despite remarkable advances in DNA sequence generation, a lack of standardized protocols and common analytical framework impede useful comparison between studies, hindering development of global inferences about microbial life on Earth. Here, we show that with coordinated protocols, exact microbial 16S rRNA gene sequences can be followed across scores of individual studies, revealing patterns of diversity, community structure, and life history strategy at a planetary scale. Using 27,751 crowdsourced environmental samples comprising more than 2.2 billion reads, wemore » find sharp divides between host-associated and free-living communities. We show that the distribution of taxonomic and sequence diversity follows consistent trends across samples types and along gradients of environmental parameters, highlighting some of the global evolutionary patterns and ecological principles that underpin Earth’s microbiome. Here, this dataset provides the most complete environmental survey of our microbial world to date, and serves as a growing reference to provide immediate global context to future microbial surveys.« less

  1. Enhanced Sensitivity for High Spatial Resolution Lipid Analysis by Negative Ion Mode MALDI Imaging Mass Spectrometry

    PubMed Central

    Angel, Peggi M.; Spraggins, Jeffrey M.; Baldwin, H. Scott; Caprioli, Richard

    2012-01-01

    We have achieved enhanced lipid imaging to a ~10 μm spatial resolution using negative ion mode matrix assisted laser desorption ionization (MALDI) imaging mass spectrometry, sublimation of 2,5-dihydroxybenzoic acid as the MALDI matrix and a sample preparation protocol that uses aqueous washes. We report on the effect of treating tissue sections by washing with volatile buffers at different pHs prior to negative ion mode lipid imaging. The results show that washing with ammonium formate, pH 6.4, or ammonium acetate, pH 6.7, significantly increases signal intensity and number of analytes recorded from adult mouse brain tissue sections. Major lipid species measured were glycerophosphoinositols, glycerophosphates, glycerolphosphoglycerols, glycerophosphoethanolamines, glycerophospho-serines, sulfatides, and gangliosides. Ion images from adult mouse brain sections that compare washed and unwashed sections are presented and show up to fivefold increases in ion intensity for washed tissue. The sample preparation protocol has been found to be applicable across numerous organ types and significantly expands the number of lipid species detectable by imaging mass spectrometry at high spatial resolution. PMID:22243218

  2. Use of a deuterated internal standard with pyrolysis-GC/MS dimeric marker analysis to quantify tire tread particles in the environment.

    PubMed

    Unice, Kenneth M; Kreider, Marisa L; Panko, Julie M

    2012-11-08

    Pyrolysis(pyr)-GC/MS analysis of characteristic thermal decomposition fragments has been previously used for qualitative fingerprinting of organic sources in environmental samples. A quantitative pyr-GC/MS method based on characteristic tire polymer pyrolysis products was developed for tread particle quantification in environmental matrices including soil, sediment, and air. The feasibility of quantitative pyr-GC/MS analysis of tread was confirmed in a method evaluation study using artificial soil spiked with known amounts of cryogenically generated tread. Tread concentration determined by blinded analyses was highly correlated (r2 ≥ 0.88) with the known tread spike concentration. Two critical refinements to the initial pyrolysis protocol were identified including use of an internal standard and quantification by the dimeric markers vinylcyclohexene and dipentene, which have good specificity for rubber polymer with no other appreciable environmental sources. A novel use of deuterated internal standards of similar polymeric structure was developed to correct the variable analyte recovery caused by sample size, matrix effects, and ion source variability. The resultant quantitative pyr-GC/MS protocol is reliable and transferable between laboratories.

  3. A communal catalogue reveals Earth’s multiscale microbial diversity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, Luke R.; Sanders, Jon G.; McDonald, Daniel

    Our growing awareness of the importance and diversity of the microbial world contrasts starkly with our limited understanding of its fundamental structure. Despite remarkable advances in DNA sequence generation, a lack of standardized protocols and common analytical framework impede useful comparison between studies, hindering development of global inferences about microbial life on Earth. Here, we show that with coordinated protocols, exact microbial 16S rRNA gene sequences can be followed across scores of individual studies, revealing patterns of diversity, community structure, and life history strategy at a planetary scale. Using 27,751 crowdsourced environmental samples comprising more than 2.2 billion reads, wemore » find sharp divides between host-associated and free-living communities. We show that the distribution of taxonomic and sequence diversity follows consistent trends across samples types and along gradients of environmental parameters, highlighting some of the global evolutionary patterns and ecological principles that underpin Earth’s microbiome. Here, this dataset provides the most complete environmental survey of our microbial world to date, and serves as a growing reference to provide immediate global context to future microbial surveys.« less

  4. An orientation soil survey at the Pebble Cu-Au-Mo porphyry deposit, Alaska

    USGS Publications Warehouse

    Smith, Steven M.; Eppinger, Robert G.; Fey, David L.; Kelley, Karen D.; Giles, S.A.

    2009-01-01

    Soil samples were collected in 2007 and 2008 along three traverses across the giant Pebble Cu-Au-Mo porphyry deposit. Within each soil pit, four subsamples were collected following recommended protocols for each of ten commonly-used and proprietary leach/digestion techniques. The significance of geochemical patterns generated by these techniques was classified by visual inspection of plots showing individual element concentration by each analytical method along the 2007 traverse. A simple matrix by element versus method, populated with a value based on the significance classification, provides a method for ranking the utility of methods and elements at this deposit. The interpretation of a complex multi-element dataset derived from multiple analytical techniques is challenging. An example of vanadium results from a single leach technique is used to illustrate the several possible interpretations of the data.

  5. Validation of an isotope dilution, ICP-MS method based on internal mass bias correction for the determination of trace concentrations of Hg in sediment cores.

    PubMed

    Ciceri, E; Recchia, S; Dossi, C; Yang, L; Sturgeon, R E

    2008-01-15

    The development and validation of a method for the determination of mercury in sediments using a sector field inductively coupled plasma mass spectrometer (SF-ICP-MS) for detection is described. The utilization of isotope dilution (ID) calibration is shown to solve analytical problems related to matrix composition. Mass bias is corrected using an internal mass bias correction technique, validated against the traditional standard bracketing method. The overall analytical protocol is validated against NRCC PACS-2 marine sediment CRM. The estimated limit of detection is 12ng/g. The proposed procedure was applied to the analysis of a real sediment core sampled to a depth of 160m in Lake Como, where Hg concentrations ranged from 66 to 750ng/g.

  6. Optimized protocol for quantitative multiple reaction monitoring-based proteomic analysis of formalin-fixed, paraffin embedded tissues

    PubMed Central

    Kennedy, Jacob J.; Whiteaker, Jeffrey R.; Schoenherr, Regine M.; Yan, Ping; Allison, Kimberly; Shipley, Melissa; Lerch, Melissa; Hoofnagle, Andrew N.; Baird, Geoffrey Stuart; Paulovich, Amanda G.

    2016-01-01

    Despite a clinical, economic, and regulatory imperative to develop companion diagnostics, precious few new biomarkers have been successfully translated into clinical use, due in part to inadequate protein assay technologies to support large-scale testing of hundreds of candidate biomarkers in formalin-fixed paraffin embedded (FFPE) tissues. While the feasibility of using targeted, multiple reaction monitoring-mass spectrometry (MRM-MS) for quantitative analyses of FFPE tissues has been demonstrated, protocols have not been systematically optimized for robust quantification across a large number of analytes, nor has the performance of peptide immuno-MRM been evaluated. To address this gap, we used a test battery approach coupled to MRM-MS with the addition of stable isotope labeled standard peptides (targeting 512 analytes) to quantitatively evaluate the performance of three extraction protocols in combination with three trypsin digestion protocols (i.e. 9 processes). A process based on RapiGest buffer extraction and urea-based digestion was identified to enable similar quantitation results from FFPE and frozen tissues. Using the optimized protocols for MRM-based analysis of FFPE tissues, median precision was 11.4% (across 249 analytes). There was excellent correlation between measurements made on matched FFPE and frozen tissues, both for direct MRM analysis (R2 = 0.94) and immuno-MRM (R2 = 0.89). The optimized process enables highly reproducible, multiplex, standardizable, quantitative MRM in archival tissue specimens. PMID:27462933

  7. Simultaneous detection of xenon and krypton in equine plasma by gas chromatography-tandem mass spectrometry for doping control.

    PubMed

    Kwok, Wai Him; Choi, Timmy L S; So, Pui-Kin; Yao, Zhong-Ping; Wan, Terence S M

    2017-02-01

    Xenon can activate the hypoxia-inducible factors (HIFs). As such, it has been allegedly used in human sports for increasing erythropoiesis. Krypton, another noble gas with reported narcosis effect, can also be expected to be a potential and less expensive erythropoiesis stimulating agent. This has raised concern about the misuse of noble gases as doping agents in equine sports. The aim of the present study is to establish a method for the simultaneous detection of xenon and krypton in equine plasma for the purpose of doping control. Xenon- or krypton-fortified equine plasma samples were prepared according to reported protocols. The target noble gases were simultaneously detected by gas chromatography-triple quadrupole mass spectrometry using headspace injection. Three xenon isotopes at m/z 129, 131, and 132, and four krypton isotopes at m/z 82, 83, 84, and 86 were targeted in selected reaction monitoring mode (with the precursor ions and product ions at identical mass settings), allowing unambiguous identification of the target analytes. Limits of detection for xenon and krypton were about 19 pmol/mL and 98 pmol/mL, respectively. Precision for both analytes was less than 15%. The method has good specificity as background analyte signals were not observed in negative equine plasma samples (n = 73). Loss of analytes under different storage temperatures has also been evaluated. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  8. Analysis of variation matrix array by bilinear least squares-residual bilinearization (BLLS-RBL) for resolving and quantifying of foodstuff dyes in a candy sample.

    PubMed

    Asadpour-Zeynali, Karim; Maryam Sajjadi, S; Taherzadeh, Fatemeh; Rahmanian, Reza

    2014-04-05

    Bilinear least square (BLLS) method is one of the most suitable algorithms for second-order calibration. Original BLLS method is not applicable to the second order pH-spectral data when an analyte has more than one spectroscopically active species. Bilinear least square-residual bilinearization (BLLS-RBL) was developed to achieve the second order advantage for analysis of complex mixtures. Although the modified method is useful, the pure profiles cannot be obtained and only the linear combination will be obtained. Moreover, for prediction of analyte in an unknown sample, the original algorithm of RBL may diverge; instead of converging to the desired analyte concentrations. Therefore, Gauss Newton-RLB algorithm should be used, which is not as simple as original protocol. Also, the analyte concentration can be predicted on the basis of each of the equilibrating species of the component of interest that are not exactly the same. The aim of the present work is to tackle the non-uniqueness problem in the second order calibration of monoprotic acid mixtures and divergence of RBL. Each pH-absorbance matrix was pretreated by subtraction of the first spectrum from other spectra in the data set to produce full rank array that is called variation matrix. Then variation matrices were analyzed uniquely by original BLLS-RBL that is more parsimonious than its modified counterpart. The proposed method was performed on the simulated as well as the analysis of real data. Sunset yellow and Carmosine as monoprotic acids were determined in candy sample in the presence of unknown interference by this method. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Evaluation of two types of swabs for sampling allograft musculoskeletal tissue.

    PubMed

    Varettas, Kerry

    2015-01-01

    Allograft musculoskeletal tissue is commonly sampled by a swab for bioburden screening. To determine if bioburden recovery could be improved at the pre-analytical stage, two swab systems were evaluated: the Amies gel swab and the ESwab. In vitro studies were performed to determine the recovery of each swab system with <100 colony-forming unit of challenge organisms using inoculated swabs and by sampling inoculated femoral heads. The standard culture protocol used in this laboratory was also evaluated after sampling of inoculated femoral heads. A prospective study was performed with both swab systems used in parallel to sample cadaveric allograft musculoskeletal tissue. The challenge organisms could be recovered from the in vitro inoculated studies. The standard culture protocol in this laboratory recovered all challenge organisms from both swab systems. One hundred and six paired Amies and ESwabs were collected from eight cadaveric donors with skin commensals the predominant isolates. The sampling of an inoculated femoral head was included to reflect routine swab sampling practice as was the inclusion of the standard method used in this laboratory. This appears to be the first study to compare Amies gel swabs with ESwabs to sample allograft femoral heads and in a prospective study with cadaveric allograft musculoskeletal tissue. Other comparative studies of swab systems have used a much higher inoculum to mimic an infection; however, sepsis is an exclusion criterion for allograft donors. It was found that the Amies gel swab and ESwab are both suitable sampling devices for bioburden testing of allograft musculoskeletal tissue. © 2014 Royal Australasian College of Surgeons.

  10. XPS Protocol for the Characterization of Pristine and Functionalized Single Wall Carbon Nanotubes

    NASA Technical Reports Server (NTRS)

    Sosa, E. D.; Allada, R.; Huffman, C. B.; Arepalli, S.

    2009-01-01

    Recent interest in developing new applications for carbon nanotubes (CNT) has fueled the need to use accurate macroscopic and nanoscopic techniques to characterize and understand their chemistry. X-ray photoelectron spectroscopy (XPS) has proved to be a useful analytical tool for nanoscale surface characterization of materials including carbon nanotubes. Recent nanotechnology research at NASA Johnson Space Center (NASA-JSC) helped to establish a characterization protocol for quality assessment for single wall carbon nanotubes (SWCNTs). Here, a review of some of the major factors of the XPS technique that can influence the quality of analytical data, suggestions for methods to maximize the quality of data obtained by XPS, and the development of a protocol for XPS characterization as a complementary technique for analyzing the purity and surface characteristics of SWCNTs is presented. The XPS protocol is then applied to a number of experiments including impurity analysis and the study of chemical modifications for SWCNTs.

  11. Raman spectroscopic analysis of geological and biogeological specimens of relevance to the ExoMars mission.

    PubMed

    Edwards, Howell G M; Hutchinson, Ian B; Ingley, Richard; Parnell, John; Vítek, Petr; Jehlička, Jan

    2013-06-01

    A novel miniaturized Raman spectrometer is scheduled to fly as part of the analytical instrumentation package on an ESA remote robotic lander in the ESA/Roscosmos ExoMars mission to search for evidence for extant or extinct life on Mars in 2018. The Raman spectrometer will be part of the first-pass analytical stage of the sampling procedure, following detailed surface examination by the PanCam scanning camera unit on the ExoMars rover vehicle. The requirements of the analytical protocol are stringent and critical; this study represents a laboratory blind interrogation of specimens that form a list of materials that are of relevance to martian exploration and at this stage simulates a test of current laboratory instrumentation to highlight the Raman technique strengths and possible weaknesses that may be encountered in practice on the martian surface and from which future studies could be formulated. In this preliminary exercise, some 10 samples that are considered terrestrial representatives of the mineralogy and possible biogeologically modified structures that may be identified on Mars have been examined with Raman spectroscopy, and conclusions have been drawn about the viability of the unambiguous spectral identification of biomolecular life signatures. It is concluded that the Raman spectroscopic technique does indeed demonstrate the capability to identify biomolecular signatures and the mineralogy in real-world terrestrial samples with a very high degree of success without any preconception being made about their origin and classification.

  12. USDA-ARS GRACEnet Project Protocols, Chapter 3. Chamber-based trace gas flux measurements4

    USDA-ARS?s Scientific Manuscript database

    This protocol addresses N2O, CO2 and CH4 flux measurement by soil chamber methodology. The reactivities of other gasses of interest such as NOx O3, CO, and NH3 will require different chambers and associated instrumentation. Carbon dioxide is included as an analyte with this protocol; however, when p...

  13. Collection of biological samples in forensic toxicology.

    PubMed

    Dinis-Oliveira, R J; Carvalho, F; Duarte, J A; Remião, F; Marques, A; Santos, A; Magalhães, T

    2010-09-01

    Forensic toxicology is the study and practice of the application of toxicology to the purposes of the law. The relevance of any finding is determined, in the first instance, by the nature and integrity of the specimen(s) submitted for analysis. This means that there are several specific challenges to select and collect specimens for ante-mortem and post-mortem toxicology investigation. Post-mortem specimens may be numerous and can endow some special difficulties compared to clinical specimens, namely those resulting from autolytic and putrefactive changes. Storage stability is also an important issue to be considered during the pre-analytic phase, since its consideration should facilitate the assessment of sample quality and the analytical result obtained from that sample. The knowledge on degradation mechanisms and methods to increase storage stability may enable the forensic toxicologist to circumvent possible difficulties. Therefore, advantages and limitations of specimen preservation procedures are thoroughfully discussed in this review. Presently, harmonized protocols for sampling in suspected intoxications would have obvious utility. In the present article an overview is given on sampling procedures for routinely collected specimens as well as on alternative specimens that may provide additional information on the route and timing of exposure to a specific xenobiotic. Last, but not least, a discussion on possible bias that can influence the interpretation of toxicological results is provided. This comprehensive review article is intented as a significant help for forensic toxicologists to accomplish their frequently overwhelming mission.

  14. Engineering of a miniaturized, robotic clinical laboratory

    PubMed Central

    Nourse, Marilyn B.; Engel, Kate; Anekal, Samartha G.; Bailey, Jocelyn A.; Bhatta, Pradeep; Bhave, Devayani P.; Chandrasekaran, Shekar; Chen, Yutao; Chow, Steven; Das, Ushati; Galil, Erez; Gong, Xinwei; Gessert, Steven F.; Ha, Kevin D.; Hu, Ran; Hyland, Laura; Jammalamadaka, Arvind; Jayasurya, Karthik; Kemp, Timothy M.; Kim, Andrew N.; Lee, Lucie S.; Liu, Yang Lily; Nguyen, Alphonso; O'Leary, Jared; Pangarkar, Chinmay H.; Patel, Paul J.; Quon, Ken; Ramachandran, Pradeep L.; Rappaport, Amy R.; Roy, Joy; Sapida, Jerald F.; Sergeev, Nikolay V.; Shee, Chandan; Shenoy, Renuka; Sivaraman, Sharada; Sosa‐Padilla, Bernardo; Tran, Lorraine; Trent, Amanda; Waggoner, Thomas C.; Wodziak, Dariusz; Yuan, Amy; Zhao, Peter; Holmes, Elizabeth A.

    2018-01-01

    Abstract The ability to perform laboratory testing near the patient and with smaller blood volumes would benefit patients and physicians alike. We describe our design of a miniaturized clinical laboratory system with three components: a hardware platform (ie, the miniLab) that performs preanalytical and analytical processing steps using miniaturized sample manipulation and detection modules, an assay‐configurable cartridge that provides consumable materials and assay reagents, and a server that communicates bidirectionally with the miniLab to manage assay‐specific protocols and analyze, store, and report results (i.e., the virtual analyzer). The miniLab can detect analytes in blood using multiple methods, including molecular diagnostics, immunoassays, clinical chemistry, and hematology. Analytical performance results show that our qualitative Zika virus assay has a limit of detection of 55 genomic copies/ml. For our anti‐herpes simplex virus type 2 immunoglobulin G, lipid panel, and lymphocyte subset panel assays, the miniLab has low imprecision, and method comparison results agree well with those from the United States Food and Drug Administration‐cleared devices. With its small footprint and versatility, the miniLab has the potential to provide testing of a range of analytes in decentralized locations. PMID:29376134

  15. Engineering of a miniaturized, robotic clinical laboratory.

    PubMed

    Nourse, Marilyn B; Engel, Kate; Anekal, Samartha G; Bailey, Jocelyn A; Bhatta, Pradeep; Bhave, Devayani P; Chandrasekaran, Shekar; Chen, Yutao; Chow, Steven; Das, Ushati; Galil, Erez; Gong, Xinwei; Gessert, Steven F; Ha, Kevin D; Hu, Ran; Hyland, Laura; Jammalamadaka, Arvind; Jayasurya, Karthik; Kemp, Timothy M; Kim, Andrew N; Lee, Lucie S; Liu, Yang Lily; Nguyen, Alphonso; O'Leary, Jared; Pangarkar, Chinmay H; Patel, Paul J; Quon, Ken; Ramachandran, Pradeep L; Rappaport, Amy R; Roy, Joy; Sapida, Jerald F; Sergeev, Nikolay V; Shee, Chandan; Shenoy, Renuka; Sivaraman, Sharada; Sosa-Padilla, Bernardo; Tran, Lorraine; Trent, Amanda; Waggoner, Thomas C; Wodziak, Dariusz; Yuan, Amy; Zhao, Peter; Young, Daniel L; Robertson, Channing R; Holmes, Elizabeth A

    2018-01-01

    The ability to perform laboratory testing near the patient and with smaller blood volumes would benefit patients and physicians alike. We describe our design of a miniaturized clinical laboratory system with three components: a hardware platform (ie, the miniLab) that performs preanalytical and analytical processing steps using miniaturized sample manipulation and detection modules, an assay-configurable cartridge that provides consumable materials and assay reagents, and a server that communicates bidirectionally with the miniLab to manage assay-specific protocols and analyze, store, and report results (i.e., the virtual analyzer). The miniLab can detect analytes in blood using multiple methods, including molecular diagnostics, immunoassays, clinical chemistry, and hematology. Analytical performance results show that our qualitative Zika virus assay has a limit of detection of 55 genomic copies/ml. For our anti-herpes simplex virus type 2 immunoglobulin G, lipid panel, and lymphocyte subset panel assays, the miniLab has low imprecision, and method comparison results agree well with those from the United States Food and Drug Administration-cleared devices. With its small footprint and versatility, the miniLab has the potential to provide testing of a range of analytes in decentralized locations.

  16. The international fine aerosol networks

    NASA Astrophysics Data System (ADS)

    Cahill, Thomas A.

    1993-04-01

    The adoption by the United States of a PIXE-based protocol for its fine aerosol network, after open competitions involving numerous laboratories and methods, has encouraged cooperation with other countries possessing similar capabilities and similar needs. These informal cooperative programs, involving about a dozen countries at the end of 1991, almost all use PIXE as a major component of the analytical protocols. The University of California, Davis, Air Quality Group assisted such programs through indefinite loans of a quality assurance sampler, the IMPROVE Channel A, and analyses at no cost of a small fraction of the samples taken in a side-by-side configuration. In December 1991, the World Meteorological Organization chose a protocol essentially identical to IMPROVE for the Global Atmospheric Watch (GAW) network and began deploying units, the IMPROVE Channel A, to sites around the world. Preferred analyses include fine (less than about 2.5 μm) mass, ions by ion chromatography and elements by PIXE + PESA (or, lacking that, XRF). This paper will describe progress in both programs, giving examples of the utility of the data and projecting the future expansion of the network to about 20 GAW sites by 1994.

  17. HIV-1 viral load measurement in venous blood and fingerprick blood using Abbott RealTime HIV-1 DBS assay.

    PubMed

    Tang, Ning; Pahalawatta, Vihanga; Frank, Andrea; Bagley, Zowie; Viana, Raquel; Lampinen, John; Leckie, Gregor; Huang, Shihai; Abravaya, Klara; Wallis, Carole L

    2017-07-01

    HIV RNA suppression is a key indicator for monitoring success of antiretroviral therapy. From a logistical perspective, viral load (VL) testing using Dried Blood Spots (DBS) is a promising alternative to plasma based VL testing in resource-limited settings. To evaluate the analytical and clinical performance of the Abbott RealTime HIV-1 assay using a fully automated one-spot DBS sample protocol. Limit of detection (LOD), linearity, lower limit of quantitation (LLQ), upper limit of quantitation (ULQ), and precision were determined using serial dilutions of HIV-1 Virology Quality Assurance stock (VQA Rush University), or HIV-1-containing armored RNA, made in venous blood. To evaluate correlation, bias, and agreement, 497 HIV-1 positive adult clinical samples were collected from Ivory Coast, Uganda and South Africa. For each HIV-1 participant, DBS-fingerprick, DBS-venous and plasma sample results were compared. Correlation and bias values were obtained. The sensitivity and specificity were analyzed at a threshold of 1000 HIV-1 copies/mL generated using the standard plasma protocol. The Abbott HIV-1 DBS protocol had an LOD of 839 copies/mL, a linear range from 500 to 1×10 7 copies/mL, an LLQ of 839 copies/mL, a ULQ of 1×10 7 copies/mL, and an inter-assay SD of ≤0.30 log copies/mL for all tested levels within this range. With clinical samples, the correlation coefficient (r value) was 0.896 between DBS-fingerprick and plasma and 0.901 between DBS-venous and plasma, and the bias was -0.07 log copies/mL between DBS-fingerprick and plasma and -0.02 log copies/mL between DBS-venous and plasma. The sensitivity of DBS-fingerprick and DBS-venous was 93%, while the specificity of both DBS methods was 95%. The results demonstrated that the Abbott RealTime HIV-1 assay with DBS sample protocol is highly sensitive, specific and precise across a wide dynamic range and correlates well with plasma values. The Abbott RealTime HIV-1 assay with DBS sample protocol provides an alternative sample collection and transfer option in resource-limited settings and expands the utility of a viral load test to monitor HIV-1 ART treatment for infected patients. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  18. Simultaneous dispersive liquid-liquid microextraction derivatisation and gas chromatography mass spectrometry analysis of subcritical water extracts of sweet and sour cherry stems.

    PubMed

    Švarc-Gajić, Jaroslava; Clavijo, Sabrina; Suárez, Ruth; Cvetanović, Aleksandra; Cerdà, Víctor

    2018-03-01

    Cherry stems have been used in traditional medicine mostly for the treatment of urinary tract infections. Extraction with subcritical water, according to its selectivity, efficiency and other aspects, differs substantially from conventional extraction techniques. The complexity of plant subcritical water extracts is due to the ability of subcritical water to extract different chemical classes of different physico-chemical properties and polarities in a single run. In this paper, dispersive liquid-liquid microextraction (DLLME) with simultaneous derivatisation was optimised for the analysis of complex subcritical water extracts of cherry stems to allow simple and rapid preparation prior to gas chromatography-mass spectrometry (GC-MS). After defining optimal extracting and dispersive solvents, the optimised method was used for the identification of compounds belonging to different chemical classes in a single analytical run. The developed sample preparation protocol enabled simultaneous extraction and derivatisation, as well as convenient coupling with GC-MS analysis, reducing the analysis time and number of steps. The applied analytical protocol allowed simple and rapid chemical screening of subcritical water extracts and was used for the comparison of subcritical water extracts of sweet and sour cherry stems. Graphical abstract DLLME GC MS analysis of cherry stem extracts obtained by subcritical water.

  19. Safe bunker designing for the 18 MV Varian 2100 Clinac: a comparison between Monte Carlo simulation based upon data and new protocol recommendations.

    PubMed

    Beigi, Manije; Afarande, Fatemeh; Ghiasi, Hosein

    2016-01-01

    The aim of this study was to compare two bunkers designed by only protocols recommendations and Monte Carlo (MC) based upon data derived for an 18 MV Varian 2100Clinac accelerator. High energy radiation therapy is associated with fast and thermal photoneutrons. Adequate shielding against the contaminant neutron has been recommended by IAEA and NCRP new protocols. The latest protocols released by the IAEA (safety report No. 47) and NCRP report No. 151 were used for the bunker designing calculations. MC method based upon data was also derived. Two bunkers using protocols and MC upon data were designed and discussed. From designed door's thickness, the door designed by the MC simulation and Wu-McGinley analytical method was closer in both BPE and lead thickness. In the case of the primary and secondary barriers, MC simulation resulted in 440.11 mm for the ordinary concrete, total concrete thickness of 1709 mm was required. Calculating the same parameters value with the recommended analytical methods resulted in 1762 mm for the required thickness using 445 mm as recommended by TVL for the concrete. Additionally, for the secondary barrier the thickness of 752.05 mm was obtained. Our results showed MC simulation and the followed protocols recommendations in dose calculation are in good agreement in the radiation contamination dose calculation. Difference between the two analytical and MC simulation methods revealed that the application of only one method for the bunker design may lead to underestimation or overestimation in dose and shielding calculations.

  20. Large-Scale Interlaboratory Study to Develop, Analytically Validate and Apply Highly Multiplexed, Quantitative Peptide Assays to Measure Cancer-Relevant Proteins in Plasma*

    PubMed Central

    Abbatiello, Susan E.; Schilling, Birgit; Mani, D. R.; Zimmerman, Lisa J.; Hall, Steven C.; MacLean, Brendan; Albertolle, Matthew; Allen, Simon; Burgess, Michael; Cusack, Michael P.; Gosh, Mousumi; Hedrick, Victoria; Held, Jason M.; Inerowicz, H. Dorota; Jackson, Angela; Keshishian, Hasmik; Kinsinger, Christopher R.; Lyssand, John; Makowski, Lee; Mesri, Mehdi; Rodriguez, Henry; Rudnick, Paul; Sadowski, Pawel; Sedransk, Nell; Shaddox, Kent; Skates, Stephen J.; Kuhn, Eric; Smith, Derek; Whiteaker, Jeffery R.; Whitwell, Corbin; Zhang, Shucha; Borchers, Christoph H.; Fisher, Susan J.; Gibson, Bradford W.; Liebler, Daniel C.; MacCoss, Michael J.; Neubert, Thomas A.; Paulovich, Amanda G.; Regnier, Fred E.; Tempst, Paul; Carr, Steven A.

    2015-01-01

    There is an increasing need in biology and clinical medicine to robustly and reliably measure tens to hundreds of peptides and proteins in clinical and biological samples with high sensitivity, specificity, reproducibility, and repeatability. Previously, we demonstrated that LC-MRM-MS with isotope dilution has suitable performance for quantitative measurements of small numbers of relatively abundant proteins in human plasma and that the resulting assays can be transferred across laboratories while maintaining high reproducibility and quantitative precision. Here, we significantly extend that earlier work, demonstrating that 11 laboratories using 14 LC-MS systems can develop, determine analytical figures of merit, and apply highly multiplexed MRM-MS assays targeting 125 peptides derived from 27 cancer-relevant proteins and seven control proteins to precisely and reproducibly measure the analytes in human plasma. To ensure consistent generation of high quality data, we incorporated a system suitability protocol (SSP) into our experimental design. The SSP enabled real-time monitoring of LC-MRM-MS performance during assay development and implementation, facilitating early detection and correction of chromatographic and instrumental problems. Low to subnanogram/ml sensitivity for proteins in plasma was achieved by one-step immunoaffinity depletion of 14 abundant plasma proteins prior to analysis. Median intra- and interlaboratory reproducibility was <20%, sufficient for most biological studies and candidate protein biomarker verification. Digestion recovery of peptides was assessed and quantitative accuracy improved using heavy-isotope-labeled versions of the proteins as internal standards. Using the highly multiplexed assay, participating laboratories were able to precisely and reproducibly determine the levels of a series of analytes in blinded samples used to simulate an interlaboratory clinical study of patient samples. Our study further establishes that LC-MRM-MS using stable isotope dilution, with appropriate attention to analytical validation and appropriate quality control measures, enables sensitive, specific, reproducible, and quantitative measurements of proteins and peptides in complex biological matrices such as plasma. PMID:25693799

  1. Liquid chromatography-mass spectrometry in metabolomics research: mass analyzers in ultra high pressure liquid chromatography coupling.

    PubMed

    Forcisi, Sara; Moritz, Franco; Kanawati, Basem; Tziotis, Dimitrios; Lehmann, Rainer; Schmitt-Kopplin, Philippe

    2013-05-31

    The present review gives an introduction into the concept of metabolomics and provides an overview of the analytical tools applied in non-targeted metabolomics with a focus on liquid chromatography (LC). LC is a powerful analytical tool in the study of complex sample matrices. A further development and configuration employing Ultra-High Pressure Liquid Chromatography (UHPLC) is optimized to provide the largest known liquid chromatographic resolution and peak capacity. Reasonably UHPLC plays an important role in separation and consequent metabolite identification of complex molecular mixtures such as bio-fluids. The most sensitive detectors for these purposes are mass spectrometers. Almost any mass analyzer can be optimized to identify and quantify small pre-defined sets of targets; however, the number of analytes in metabolomics is far greater. Optimized protocols for quantification of large sets of targets may be rendered inapplicable. Results on small target set analyses on different sample matrices are easily comparable with each other. In non-targeted metabolomics there is almost no analytical method which is applicable to all different matrices due to limitations pertaining to mass analyzers and chromatographic tools. The specifications of the most important interfaces and mass analyzers are discussed. We additionally provide an exemplary application in order to demonstrate the level of complexity which remains intractable up to date. The potential of coupling a high field Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (ICR-FT/MS), the mass analyzer with the largest known mass resolving power, to UHPLC is given with an example of one human pre-treated plasma sample. This experimental example illustrates one way of overcoming the necessity of faster scanning rates in the coupling with UHPLC. The experiment enabled the extraction of thousands of features (analytical signals). A small subset of this compositional space could be mapped into a mass difference network whose topology shows specificity toward putative metabolite classes and retention time. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Quantitative Assessment of In-solution Digestion Efficiency Identifies Optimal Protocols for Unbiased Protein Analysis*

    PubMed Central

    León, Ileana R.; Schwämmle, Veit; Jensen, Ole N.; Sprenger, Richard R.

    2013-01-01

    The majority of mass spectrometry-based protein quantification studies uses peptide-centric analytical methods and thus strongly relies on efficient and unbiased protein digestion protocols for sample preparation. We present a novel objective approach to assess protein digestion efficiency using a combination of qualitative and quantitative liquid chromatography-tandem MS methods and statistical data analysis. In contrast to previous studies we employed both standard qualitative as well as data-independent quantitative workflows to systematically assess trypsin digestion efficiency and bias using mitochondrial protein fractions. We evaluated nine trypsin-based digestion protocols, based on standard in-solution or on spin filter-aided digestion, including new optimized protocols. We investigated various reagents for protein solubilization and denaturation (dodecyl sulfate, deoxycholate, urea), several trypsin digestion conditions (buffer, RapiGest, deoxycholate, urea), and two methods for removal of detergents before analysis of peptides (acid precipitation or phase separation with ethyl acetate). Our data-independent quantitative liquid chromatography-tandem MS workflow quantified over 3700 distinct peptides with 96% completeness between all protocols and replicates, with an average 40% protein sequence coverage and an average of 11 peptides identified per protein. Systematic quantitative and statistical analysis of physicochemical parameters demonstrated that deoxycholate-assisted in-solution digestion combined with phase transfer allows for efficient, unbiased generation and recovery of peptides from all protein classes, including membrane proteins. This deoxycholate-assisted protocol was also optimal for spin filter-aided digestions as compared with existing methods. PMID:23792921

  3. Protocol proposal for, and evaluation of, consistency in nicotine delivery from the liquid to the aerosol of electronic cigarettes atomizers: regulatory implications.

    PubMed

    Farsalinos, Konstantinos E; Yannovits, Nikoletta; Sarri, Theoni; Voudris, Vassilis; Poulas, Konstantinos

    2016-06-01

    To propose a protocol and evaluate the consistency in nicotine delivery to the aerosol of different types of electronic cigarette (EC) atomizers, as required by regulatory authorities. Three cartomizer and four tank-type atomizer products were tested (three samples per product). The aerosol from three 20-puff sessions from each sample was collected using a smoke machine. Three cartridges from a nicotine inhaler and three tobacco cigarettes were also tested. Analytical laboratory in Greece. Aerosol nicotine levels were measured. Relative standard deviation (RSD, i.e. coefficient of variation) was calculated separately for each cartomizer and replacement atomizer head sample (intrasample RSD) and between different samples (intersample RSD). The percentage difference from the mean, which is used to assess the quality of medicinal nebulizers, was also calculated. The aerosol nicotine levels were 1.01-10.61 mg/20 puffs for ECs, 0.12-0.18 mg/20 puffs for the nicotine inhaler and 1.76-2.20 mg/cigarette for the tobacco cigarettes. The intrasample RSDs were 3.7-12.5% for ECs and 14.3% for the nicotine inhaler and 11.1% for the tobacco cigarettes. The intersample RSDs were higher in cartomizers (range: 6.9-37.8%) compared with tank systems (range: 6.4-9.3%). All tank-type atomizers and one cartomizer were within 75-125% of the mean, as dictated for medicinal nebulizers. Electronic cigarettes that use tank-type atomizers appear to deliver nicotine in more consistent quantities (within the acceptable limits for medicinal nebulizers and similar to the nicotine inhaler) than electronic cigarettes that use cartomizers. The protocol for testing nicotine delivery consistency described in this paper could be used effectively for regulatory purposes. © 2016 Society for the Study of Addiction.

  4. Optimal molecular profiling of tissue and tissue components: defining the best processing and microdissection methods for biomedical applications.

    PubMed

    Rodriguez-Canales, Jaime; Hanson, Jeffrey C; Hipp, Jason D; Balis, Ulysses J; Tangrea, Michael A; Emmert-Buck, Michael R; Bova, G Steven

    2013-01-01

    Isolation of well-preserved pure cell populations is a prerequisite for sound studies of the molecular basis of any tissue-based biological phenomenon. This updated chapter reviews current methods for obtaining anatomically specific signals from molecules isolated from tissues, a basic requirement for productive linking of phenotype and genotype. The quality of samples isolated from tissue and used for molecular analysis is often glossed over or omitted from publications, making interpretation and replication of data difficult or impossible. Fortunately, recently developed techniques allow life scientists to better document and control the quality of samples used for a given assay, creating a foundation for improvement in this area. Tissue processing for molecular studies usually involves some or all of the following steps: tissue collection, gross dissection/identification, fixation, processing/embedding, storage/archiving, sectioning, staining, microdissection/annotation, and pure analyte labeling/identification and quantification. We provide a detailed comparison of some current tissue microdissection technologies and provide detailed example protocols for tissue component handling upstream and downstream from microdissection. We also discuss some of the physical and chemical issues related to optimal tissue processing and include methods specific to cytology specimens. We encourage each laboratory to use these as a starting point for optimization of their overall process of moving from collected tissue to high-quality, appropriately anatomically tagged scientific results. Improvement in this area will significantly increase life science quality and productivity. The chapter is divided into introduction, materials, protocols, and notes subheadings. Because many protocols are covered in each of these sections, information relating to a single protocol is not contiguous. To get the greatest benefit from this chapter, readers are advised to read through the entire chapter first, identify protocols appropriate to their laboratory for each step in their workflow, and then reread entries in each section pertaining to each of these single protocols.

  5. Standardization and validation of real time PCR assays for the diagnosis of histoplasmosis using three molecular targets in an animal model.

    PubMed

    López, Luisa F; Muñoz, César O; Cáceres, Diego H; Tobón, Ángela M; Loparev, Vladimir; Clay, Oliver; Chiller, Tom; Litvintseva, Anastasia; Gade, Lalitha; González, Ángel; Gómez, Beatriz L

    2017-01-01

    Histoplasmosis is considered one of the most important endemic and systemic mycoses worldwide. Until now few molecular techniques have been developed for its diagnosis. The aim of this study was to develop and evaluate three real time PCR (qPCR) protocols for different protein-coding genes (100-kDa, H and M antigens) using an animal model. Fresh and formalin-fixed and paraffin-embedded (FFPE) lung tissues from BALB/c mice inoculated i.n. with 2.5x106 Histoplasma capsulatum yeast or PBS were obtained at 1, 2, 3, 4, 8, 12 and 16 weeks post-infection. A collection of DNA from cultures representing different clades of H. capsulatum (30 strains) and other medically relevant pathogens (36 strains of related fungi and Mycobacterium tuberculosis) were used to analyze sensitivity and specificity. Analytical sensitivity and specificity were 100% when DNAs from the different strains were tested. The highest fungal burden occurred at first week post-infection and complete fungal clearance was observed after the third week; similar results were obtained when the presence of H. capsulatum yeast cells was demonstrated in histopathological analysis. In the first week post-infection, all fresh and FFPE lung tissues from H. capsulatum-infected animals were positive for the qPCR protocols tested except for the M antigen protocol, which gave variable results when fresh lung tissue samples were analyzed. In the second week, all qPCR protocols showed variable results for both fresh and FFPE tissues. Samples from the infected mice at the remaining times post-infection and uninfected mice (controls) were negative for all protocols. Good agreement was observed between CFUs, histopathological analysis and qPCR results for the 100-kDa and H antigen protocols. We successfully standardized and validated three qPCR assays for detecting H. capsulatum DNA in fresh and FFPE tissues, and conclude that the 100-kDa and H antigen molecular assays are promising tests for diagnosing this mycosis.

  6. Automated selected reaction monitoring data analysis workflow for large-scale targeted proteomic studies.

    PubMed

    Surinova, Silvia; Hüttenhain, Ruth; Chang, Ching-Yun; Espona, Lucia; Vitek, Olga; Aebersold, Ruedi

    2013-08-01

    Targeted proteomics based on selected reaction monitoring (SRM) mass spectrometry is commonly used for accurate and reproducible quantification of protein analytes in complex biological mixtures. Strictly hypothesis-driven, SRM assays quantify each targeted protein by collecting measurements on its peptide fragment ions, called transitions. To achieve sensitive and accurate quantitative results, experimental design and data analysis must consistently account for the variability of the quantified transitions. This consistency is especially important in large experiments, which increasingly require profiling up to hundreds of proteins over hundreds of samples. Here we describe a robust and automated workflow for the analysis of large quantitative SRM data sets that integrates data processing, statistical protein identification and quantification, and dissemination of the results. The integrated workflow combines three software tools: mProphet for peptide identification via probabilistic scoring; SRMstats for protein significance analysis with linear mixed-effect models; and PASSEL, a public repository for storage, retrieval and query of SRM data. The input requirements for the protocol are files with SRM traces in mzXML format, and a file with a list of transitions in a text tab-separated format. The protocol is especially suited for data with heavy isotope-labeled peptide internal standards. We demonstrate the protocol on a clinical data set in which the abundances of 35 biomarker candidates were profiled in 83 blood plasma samples of subjects with ovarian cancer or benign ovarian tumors. The time frame to realize the protocol is 1-2 weeks, depending on the number of replicates used in the experiment.

  7. Depression screening and management among adolescents in primary care: factors associated with best practice.

    PubMed

    Taliaferro, Lindsay A; Hetler, Joel; Edwall, Glenace; Wright, Catherine; Edwards, Anne R; Borowsky, Iris W

    2013-06-01

    To compare depression identification and management perceptions and practices between professions and disciplines in primary care and examine factors that increase the likelihood of administering a standardized depression screening instrument, asking about patients' depressive symptoms, and using best practice when managing depressed adolescents. Data came from an online survey of clinicians in Minnesota (20% response rate). Analyses involved bivariate tests and linear regressions. The analytic sample comprised 260 family medicine physicians, 127 pediatricians, 96 family nurse practitioners, and 54 pediatric nurse practitioners. Overall, few differences emerged between physicians and nurse practitioners or family and pediatric clinicians regarding addressing depression among adolescents. Two factors associated with administering a standardized instrument included having clear protocols for follow-up after depression screening and feeling better prepared to address depression among adolescents. Enhancing clinicians' competence to address depression and developing postscreening protocols could help providers implement universal screening in primary care.

  8. Preoperative vestibular assessment protocol of cochlear implant surgery: an analytical descriptive study.

    PubMed

    Bittar, Roseli Saraiva Moreira; Sato, Eduardo Setsuo; Ribeiro, Douglas Jósimo Silva; Tsuji, Robinson Koji

    Cochlear implants are undeniably an effective method for the recovery of hearing function in patients with hearing loss. To describe the preoperative vestibular assessment protocol in subjects who will be submitted to cochlear implants. Our institutional protocol provides the vestibular diagnosis through six simple tests: Romberg and Fukuda tests, assessment for spontaneous nystagmus, Head Impulse Test, evaluation for Head Shaking Nystagmus and caloric test. 21 patients were evaluated with a mean age of 42.75±14.38 years. Only 28% of the sample had all normal test results. The presence of asymmetric vestibular information was documented through the caloric test in 32% of the sample and spontaneous nystagmus was an important clue for the diagnosis. Bilateral vestibular areflexia was present in four subjects, unilateral arreflexia in three and bilateral hyporeflexia in two. The Head Impulse Test was a significant indicator for the diagnosis of areflexia in the tested ear (p=0.0001). The sensitized Romberg test using a foam pad was able to diagnose severe vestibular function impairment (p=0.003). The six clinical tests were able to identify the presence or absence of vestibular function and function asymmetry between the ears of the same individual. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  9. Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection

    PubMed Central

    Ruman, Marek; Narkowicz, Sylwia; Namieśnik, Jacek

    2017-01-01

    A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1–100 μg/L for urine, 5–100 μg/L for saliva, and 3–100 μg/L for sweat samples with determination coefficients (R) > 0.992. Low detection limits (LODs) in the range of 1.8 μg/L, 5.1 μg/L, and 5.8 μg/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n = 3) were obtained. The proposed method has been successfully applied to the analysis of human biological samples. PMID:29348966

  10. Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection.

    PubMed

    Jaszczak, Ewa; Ruman, Marek; Narkowicz, Sylwia; Namieśnik, Jacek; Polkowska, Żaneta

    2017-01-01

    A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1-100  μ g/L for urine, 5-100  μ g/L for saliva, and 3-100  μ g/L for sweat samples with determination coefficients ( R ) > 0.992. Low detection limits (LODs) in the range of 1.8  μ g/L, 5.1  μ g/L, and 5.8  μ g/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n = 3) were obtained. The proposed method has been successfully applied to the analysis of human biological samples.

  11. La–Ce isotope measurements by multicollector-ICPMS† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c7ja00256d

    PubMed Central

    Münker, Carsten; Strub, Erik

    2017-01-01

    The 138La–138Ce decay system (half-life 1.02 × 1011 years) is a potentially highly useful tool to unravel information about the timing of geological processes and about the interaction of geological reservoirs on earth, complementing information from the more popular 147Sm–143Nd and 176Lu–176Hf isotope systems. Previously published analytical protocols were limited to TIMS. Here we present for the first time an analytical protocol that employs MC-ICPMS, with an improved precision and sensitivity. To perform sufficiently accurate La–Ce measurements, an efficient ion-chromatographic procedure is required to separate Ce from the other rare earth elements (REE) and Ba quantitatively. This study presents an improved ion-chromatographic procedure that separates La and Ce from rock samples using a three-step column separation. After REE separation by cation exchange, Ce is separated employing an Ln Spec column and selective oxidation. In the last step, a cation clean-up chemistry is performed to remove all remaining interferences. Our MC-ICPMS measurement protocol includes all stable Ce isotopes (136Ce, 138Ce, 140Ce and 142Ce), by employing a 1010 ohm amplifier for the most abundant isotope 140Ce. An external reproducibility of ±0.25ε-units (2 r.s.d) has been routinely achieved for 138Ce measurements for as little as 150–600 ng Ce, depending on the sample–skimmer cone combinations being used. Because the traditionally used JMC-304 Ce reference material is not commercially available anymore, a new reference material was prepared from AMES laboratory Ce metal (Cologne-AMES). In order to compare the new material with the previously reported isotopic composition of AMES material prepared at Mainz (Mainz-AMES), Cologne-AMES and JMC-304 were measured relative to each other in the same analytical session, demonstrating isotope heterogeneity between the two AMES and different JMC-304 batches used in the literature. To enable sufficiently precise age correction of radiogenic 138Ce and to perform isochron dating, a protocol was developed where La and Ce concentrations are determined by isotope dilution (ID), using an isotope tracer enriched in 138La and 142Ce. The new protocols were applied to determine the variations of Ce isotope compositions and La–Ce concentrations of certified geochemical reference materials (CRMs): BCR-2, BCR-1, BHVO-2, JR-1, JA-2, JB-3, JG-1, JR-1, JB-1b, AGV-1 and one in-house La Palma standard. PMID:29456283

  12. Evaluating Trends in Historical PM2.5 Element Concentrations by Reanalyzing a 15-Year Sample Archive

    NASA Astrophysics Data System (ADS)

    Hyslop, N. P.; White, W. H.; Trzepla, K.

    2014-12-01

    The IMPROVE (Interagency Monitoring of PROtected Visual Environments) network monitors aerosol concentrations at 170 remote sites throughout the United States. Twenty-four-hour filter samples of particulate matter are collected every third day and analyzed for chemical composition. About 30 of the sites have operated continuously since 1988, and the sustained data record (http://views.cira.colostate.edu/web/) offers a unique window on regional aerosol trends. All elemental analyses have been performed by Crocker Nuclear Laboratory at the University of California in Davis, and sample filters collected since 1995 are archived on campus. The suite of reported elements has remained constant, but the analytical methods employed for their determination have evolved. For example, the elements Na - Mn were determined by PIXE until November 2001, then by XRF analysis in a He-flushed atmosphere through 2004, and by XRF analysis in vacuum since January 2005. In addition to these fundamental changes, incompletely-documented operational factors such as detector performance and calibration details have introduced variations in the measurements. Because the past analytical methods were non-destructive, the archived filters can be re-analyzed with the current analytical systems and protocols. The 15-year sample archives from Great Smoky Mountains (GRSM), Mount Rainier (MORA), and Point Reyes National Parks (PORE) were selected for reanalysis. The agreement between the new analyses and original determinations varies with element and analytical era. The graph below compares the trend estimates for all the elements measured by IMPROVE based on the original and repeat analyses; the elements identified in color are measured above the detection limit more than 90% of the time. The trend estimates are sensitive to the treatment of non-detect data. The original and reanalysis trends are indistinguishable (have overlapping confidence intervals) for most of the well-detected elements.

  13. Reanalysis of a 15-year Archive of IMPROVE Samples

    NASA Astrophysics Data System (ADS)

    Hyslop, N. P.; White, W. H.; Trzepla, K.

    2013-12-01

    The IMPROVE (Interagency Monitoring of PROtected Visual Environments) network monitors aerosol concentrations at 170 remote sites throughout the United States. Twenty-four-hour filter samples of particulate matter are collected every third day and analyzed for chemical composition. About 30 of the sites have operated continuously since 1988, and the sustained data record (http://views.cira.colostate.edu/web/) offers a unique window on regional aerosol trends. All elemental analyses have been performed by Crocker Nuclear Laboratory at the University of California in Davis, and sample filters collected since 1995 are archived on campus. The suite of reported elements has remained constant, but the analytical methods employed for their determination have evolved. For example, the elements Na - Mn were determined by PIXE until November 2001, then by XRF analysis in a He-flushed atmosphere through 2004, and by XRF analysis in vacuum since January 2005. In addition to these fundamental changes, incompletely-documented operational factors such as detector performance and calibration details have introduced variations in the measurements. Because the past analytical methods were non-destructive, the archived filters can be re-analyzed with the current analytical systems and protocols. The 15-year sample archives from Great Smoky Mountains, Mount Rainier, and Point Reyes National Parks were selected for reanalysis. The agreement between the new analyses and original determinations varies with element and analytical era (Figure 1). Temporal trends for some elements are affected by these changes in measurement technique while others are not (Figure 2). Figure 1. Repeatability of analyses for sulfur and vanadium at Great Smoky Mountains National Park. Each point shows the ratio of mass loadings determined by the original analysis and recent reanalysis. Major method distinctions are indicated at the top. Figure 2. Trends, based on Thiel-Sen regression, in lead concentrations based on the original and reanalysis data.

  14. Optimizing use of the structural chemical analyser (variable pressure FESEM-EDX Raman spectroscopy) on micro-size complex historical paintings characterization.

    PubMed

    Guerra, I; Cardell, C

    2015-10-01

    The novel Structural Chemical Analyser (hyphenated Raman spectroscopy and scanning electron microscopy equipped with an X-ray detector) is gaining popularity since it allows 3-D morphological studies and elemental, molecular, structural and electronic analyses of a single complex micro-sized sample without transfer between instruments. However, its full potential remains unexploited in painting heritage where simultaneous identification of inorganic and organic materials in paintings is critically yet unresolved. Despite benefits and drawbacks shown in literature, new challenges have to be faced analysing multifaceted paint specimens. SEM-Structural Chemical Analyser systems differ since they are fabricated ad hoc by request. As configuration influences the procedure to optimize analyses, likewise analytical protocols have to be designed ad hoc. This paper deals with the optimization of the analytical procedure of a Variable Pressure Field Emission scanning electron microscopy equipped with an X-ray detector Raman spectroscopy system to analyse historical paint samples. We address essential parameters, technical challenges and limitations raised from analysing paint stratigraphies, archaeological samples and loose pigments. We show that accurate data interpretation requires comprehensive knowledge of factors affecting Raman spectra. We tackled: (i) the in-FESEM-Raman spectroscopy analytical sequence, (ii) correlations between FESEM and Structural Chemical Analyser/laser analytical position, (iii) Raman signal intensity under different VP-FESEM vacuum modes, (iv) carbon deposition on samples under FESEM low-vacuum mode, (v) crystal nature and morphology, (vi) depth of focus and (vii) surface-enhanced Raman scattering effect. We recommend careful planning of analysis strategies prior to research which, although time consuming, guarantees reliable results. The ultimate goal of this paper is to help to guide future users of a FESEM-Structural Chemical Analyser system in order to increase applications. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  15. Heavy vehicle driver workload assessment. Task 1, task analysis data and protocols review

    DOT National Transportation Integrated Search

    This report contains a review of available task analytic data and protocols pertinent to heavy vehicle operation and determination of the availability and relevance of such data to heavy vehicle driver workload assessment. Additionally, a preliminary...

  16. Large-scale pesticide testing in olives by liquid chromatography-electrospray tandem mass spectrometry using two sample preparation methods based on matrix solid-phase dispersion and QuEChERS.

    PubMed

    Gilbert-López, Bienvenida; García-Reyes, Juan F; Lozano, Ana; Fernández-Alba, Amadeo R; Molina-Díaz, Antonio

    2010-09-24

    In this work we have evaluated the performance of two sample preparation methodologies for the large-scale multiresidue analysis of pesticides in olives using liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS). The tested sample treatment methodologies were: (1) liquid-liquid partitioning with acetonitrile followed by dispersive solid-phase extraction clean-up using GCB, PSA and C18 sorbents (QuEChERS method - modified for fatty vegetables) and (2) matrix solid-phase dispersion (MSPD) using aminopropyl as sorbent material and a final clean-up performed in the elution step using Florisil. An LC-MS/MS method covering 104 multiclass pesticides was developed to examine the performance of these two protocols. The separation of the compounds from the olive extracts was achieved using a short C18 column (50 mm x 4.6 mm i.d.) with 1.8 microm particle size. The identification and confirmation of the compounds was based on retention time matching along with the presence (and ratio) of two typical MRM transitions. Limits of detection obtained were lower than 10 microgkg(-1) for 89% analytes using both sample treatment protocols. Recoveries studies performed on olives samples spiked at two concentration levels (10 and 100 microgkg(-1)) yielded average recoveries in the range 70-120% for most analytes when QuEChERS procedure is employed. When MSPD was the choice for sample extraction, recoveries obtained were in the range 50-70% for most of target compounds. The proposed methods were successfully applied to the analysis of real olives samples, revealing the presence of some of the target species in the microgkg(-1) range. Besides the evaluation of the sample preparation approaches, we also discuss the use of advanced software features associated to MRM method development that overcome several limitations and drawbacks associated to MS/MS methods (time segments boundaries, tedious method development/manual scheduling and acquisition limitations). This software feature recently offered by different vendors is based on an algorithm that associates retention time data for each individual MS/MS transition, so that the number of simultaneously traced transitions throughout the entire chromatographic run (dwell times and sensitivity) is maximized. Copyright 2010 Elsevier B.V. All rights reserved.

  17. Purification, characterization and crystallization of the human 80S ribosome

    PubMed Central

    Khatter, Heena; Myasnikov, Alexander G.; Mastio, Leslie; Billas, Isabelle M. L.; Birck, Catherine; Stella, Stefano; Klaholz, Bruno P.

    2014-01-01

    Ribosomes are key macromolecular protein synthesis machineries in the cell. Human ribosomes have so far not been studied to atomic resolution because of their particularly complex structure as compared with other eukaryotic or prokaryotic ribosomes, and they are difficult to prepare to high homogeneity, which is a key requisite for high-resolution structural work. We established a purification protocol for human 80S ribosomes isolated from HeLa cells that allows obtaining large quantities of homogenous samples as characterized by biophysical methods using analytical ultracentrifugation and multiangle laser light scattering. Samples prepared under different conditions were characterized by direct single particle imaging using cryo electron microscopy, which helped optimizing the preparation protocol. From a small data set, a 3D reconstruction at subnanometric resolution was obtained showing all prominent structural features of the human ribosome, and revealing a salt concentration dependence of the presence of the exit site tRNA, which we show is critical for obtaining crystals. With these well-characterized samples first human 80S ribosome crystals were obtained from several crystallization conditions in capillaries and sitting drops, which diffract to 26 Å resolution at cryo temperatures and for which the crystallographic parameters were determined, paving the way for future high-resolution work. PMID:24452798

  18. Non-invasive prenatal diagnosis of paternally inherited disorders from maternal plasma: detection of NF1 and CFTR mutations using droplet digital PCR.

    PubMed

    Gruber, Aurélia; Pacault, Mathilde; El Khattabi, Laila Allach; Vaucouleur, Nicolas; Orhant, Lucie; Bienvenu, Thierry; Girodon, Emmanuelle; Vidaud, Dominique; Leturcq, France; Costa, Catherine; Letourneur, Franck; Anselem, Olivia; Tsatsaris, Vassilis; Goffinet, François; Viot, Géraldine; Vidaud, Michel; Nectoux, Juliette

    2018-04-25

    To limit risks of miscarriages associated with invasive procedures of current prenatal diagnosis practice, we aim to develop a personalized medicine-based protocol for non-invasive prenatal diagnosis (NIPD) of monogenic disorders relying on the detection of paternally inherited mutations in maternal blood using droplet digital PCR (ddPCR). This study included four couples at risk of transmitting paternal neurofibromatosis type 1 (NF1) mutations and four couples at risk of transmitting compound heterozygous CFTR mutations. NIPD was performed between 8 and 15 weeks of gestation, in parallel to conventional invasive diagnosis. We designed specific hydrolysis probes to detect the paternal mutation and to assess the presence of cell-free fetal DNA by ddPCR. Analytical performances of each assay were determined from paternal sample, an then fetal genotype was inferred from maternal plasma sample. Presence or absence of the paternal mutant allele was correctly determined in all the studied plasma DNA samples. We report an NIPD protocol suitable for implementation in an experienced laboratory of molecular genetics. Our proof-of-principle results point out a high accuracy for early detection of paternal NF1 and CFTR mutations in cell-free DNA, and open new perspectives for extending the technology to NIPD of many other monogenic diseases.

  19. Chromatographic multivariate quality control of pharmaceuticals giving strongly overlapped peaks based on the chromatogram profile.

    PubMed

    Escuder-Gilabert, L; Ruiz-Roch, D; Villanueva-Camañas, R M; Medina-Hernández, M J; Sagrado, S

    2004-03-12

    In the present paper, the simultaneous quantification of two analytes showing strongly overlapped chromatographic peaks (alpha = 1.02), under the assumption that both available equipment and training of the laboratory staff are basic, is studied. A pharmaceutical preparation (Mutabase) containing two drugs of similar physicochemical properties (amitriptyline and perphenazine) is selected as case of study. The assays are carried out under realistic working conditions (i.e. routine testing laboratories). Uncertainty considerations are introduced in the study. A partial least squares model is directly applied to the chromatographic data (with no previous signal transformation) to perform quality control of the pharmaceutical formulation. Under the adequate protocol, the relative error in prediction of analytes is within the tolerances found in the pharmacopeia (10%). For spiked samples simulating formulation mistakes, the errors found have the same magnitude and sign to those provoked.

  20. Urinary cell-free DNA is a versatile analyte for monitoring infections of the urinary tract.

    PubMed

    Burnham, Philip; Dadhania, Darshana; Heyang, Michael; Chen, Fanny; Westblade, Lars F; Suthanthiran, Manikkam; Lee, John Richard; De Vlaminck, Iwijn

    2018-06-20

    Urinary tract infections are one of the most common infections in humans. Here we tested the utility of urinary cell-free DNA (cfDNA) to comprehensively monitor host and pathogen dynamics in bacterial and viral urinary tract infections. We isolated cfDNA from 141 urine samples from a cohort of 82 kidney transplant recipients and performed next-generation sequencing. We found that urinary cfDNA is highly informative about bacterial and viral composition of the microbiome, antimicrobial susceptibility, bacterial growth dynamics, kidney allograft injury, and host response to infection. These different layers of information are accessible from a single assay and individually agree with corresponding clinical tests based on quantitative PCR, conventional bacterial culture, and urinalysis. In addition, cfDNA reveals the frequent occurrence of pathologies that remain undiagnosed with conventional diagnostic protocols. Our work identifies urinary cfDNA as a highly versatile analyte to monitor infections of the urinary tract.

  1. Detection of genetically modified organisms in foods by DNA amplification techniques.

    PubMed

    García-Cañas, Virginia; Cifuentes, Alejandro; González, Ramón

    2004-01-01

    In this article, the different DNA amplification techniques that are being used for detecting genetically modified organisms (GMOs) in foods are examined. This study intends to provide an updated overview (including works published till June 2002) on the principal applications of such techniques together with their main advantages and drawbacks in GMO detection in foods. Some relevant facts on sampling, DNA isolation, and DNA amplification methods are discussed. Moreover; these analytical protocols are discuissed from a quantitative point of view, including the newest investigations on multiplex detection of GMOs in foods and validation of methods.

  2. Transgenes in Mexican maize: molecular evidence and methodological considerations for GMO detection in landrace populations

    PubMed Central

    PIÑEYRO-NELSON, A; VAN HEERWAARDEN, J; PERALES, H R; SERRATOS-HERNÁNDEZ, J A; RANGEL, A; HUFFORD, M B; GEPTS, P; GARAY-ARROYO, A; RIVERA-BUSTAMANTE, R; ÁLVAREZ-BUYLLA, E R

    2009-01-01

    A possible consequence of planting genetically modified organisms (GMOs) in centres of crop origin is unintended gene flow into traditional landraces. In 2001, a study reported the presence of the transgenic 35S promoter in maize landraces sampled in 2000 from the Sierra Juarez of Oaxaca, Mexico. Analysis of a large sample taken from the same region in 2003 and 2004 could not confirm the existence of transgenes, thereby casting doubt on the earlier results. These two studies were based on different sampling and analytical procedures and are thus hard to compare. Here, we present new molecular data for this region that confirm the presence of transgenes in three of 23 localities sampled in 2001. Transgene sequences were not detected in samples taken in 2002 from nine localities, while directed samples taken in 2004 from two of the positive 2001 localities were again found to contain transgenic sequences. These findings suggest the persistence or re-introduction of transgenes up until 2004 in this area. We address variability in recombinant sequence detection by analyzing the consistency of current molecular assays. We also present theoretical results on the limitations of estimating the probability of transgene detection in samples taken from landraces. The inclusion of a limited number of female gametes and, more importantly, aggregated transgene distributions may significantly lower detection probabilities. Our analytical and sampling considerations help explain discrepancies among different detection efforts, including the one presented here, and provide considerations for the establishment of monitoring protocols to detect the presence of transgenes among structured populations of landraces. PMID:19143938

  3. Transgenes in Mexican maize: molecular evidence and methodological considerations for GMO detection in landrace populations.

    PubMed

    Piñeyro-Nelson, A; Van Heerwaarden, J; Perales, H R; Serratos-Hernández, J A; Rangel, A; Hufford, M B; Gepts, P; Garay-Arroyo, A; Rivera-Bustamante, R; Alvarez-Buylla, E R

    2009-02-01

    A possible consequence of planting genetically modified organisms (GMOs) in centres of crop origin is unintended gene flow into traditional landraces. In 2001, a study reported the presence of the transgenic 35S promoter in maize landraces sampled in 2000 from the Sierra Juarez of Oaxaca, Mexico. Analysis of a large sample taken from the same region in 2003 and 2004 could not confirm the existence of transgenes, thereby casting doubt on the earlier results. These two studies were based on different sampling and analytical procedures and are thus hard to compare. Here, we present new molecular data for this region that confirm the presence of transgenes in three of 23 localities sampled in 2001. Transgene sequences were not detected in samples taken in 2002 from nine localities, while directed samples taken in 2004 from two of the positive 2001 localities were again found to contain transgenic sequences. These findings suggest the persistence or re-introduction of transgenes up until 2004 in this area. We address variability in recombinant sequence detection by analyzing the consistency of current molecular assays. We also present theoretical results on the limitations of estimating the probability of transgene detection in samples taken from landraces. The inclusion of a limited number of female gametes and, more importantly, aggregated transgene distributions may significantly lower detection probabilities. Our analytical and sampling considerations help explain discrepancies among different detection efforts, including the one presented here, and provide considerations for the establishment of monitoring protocols to detect the presence of transgenes among structured populations of landraces.

  4. Immunosuppressant therapeutic drug monitoring by LC-MS/MS: workflow optimization through automated processing of whole blood samples.

    PubMed

    Marinova, Mariela; Artusi, Carlo; Brugnolo, Laura; Antonelli, Giorgia; Zaninotto, Martina; Plebani, Mario

    2013-11-01

    Although, due to its high specificity and sensitivity, LC-MS/MS is an efficient technique for the routine determination of immunosuppressants in whole blood, it involves time-consuming manual sample preparation. The aim of the present study was therefore to develop an automated sample-preparation protocol for the quantification of sirolimus, everolimus and tacrolimus by LC-MS/MS using a liquid handling platform. Six-level commercially available blood calibrators were used for assay development, while four quality control materials and three blood samples from patients under immunosuppressant treatment were employed for the evaluation of imprecision. Barcode reading, sample re-suspension, transfer of whole blood samples into 96-well plates, addition of internal standard solution, mixing, and protein precipitation were performed with a liquid handling platform. After plate filtration, the deproteinised supernatants were submitted for SPE on-line. The only manual steps in the entire process were de-capping of the tubes, and transfer of the well plates to the HPLC autosampler. Calibration curves were linear throughout the selected ranges. The imprecision and accuracy data for all analytes were highly satisfactory. The agreement between the results obtained with manual and those obtained with automated sample preparation was optimal (n=390, r=0.96). In daily routine (100 patient samples) the typical overall total turnaround time was less than 6h. Our findings indicate that the proposed analytical system is suitable for routine analysis, since it is straightforward and precise. Furthermore, it incurs less manual workload and less risk of error in the quantification of whole blood immunosuppressant concentrations than conventional methods. © 2013.

  5. STANDARDIZATION AND VALIDATION OF MICROBIOLOGICAL METHODS FOR EXAMINATION OF BIOSOLIDS

    EPA Science Inventory

    The objective of this presentation is to discuss pathogens of concern in biosolids, the analytical techniques used to evaluate microorganisms in biosolids, and to discuss standardization and validation of analytical protocols for microbes within a complex matrix. Implications of ...

  6. LABORATORY MISCONDUCT - WHAT CAN HAPPEN TO YOU?

    EPA Science Inventory

    Contracted laboratories perform a vast number of routine and special analytical services that are the foundation of decisions upon which rests the fate of the environment. Guiding these laboratories in the generation of environmental data has been the analytical protocols and ...

  7. Safe bunker designing for the 18 MV Varian 2100 Clinac: a comparison between Monte Carlo simulation based upon data and new protocol recommendations

    PubMed Central

    Beigi, Manije; Afarande, Fatemeh; Ghiasi, Hosein

    2016-01-01

    Aim The aim of this study was to compare two bunkers designed by only protocols recommendations and Monte Carlo (MC) based upon data derived for an 18 MV Varian 2100Clinac accelerator. Background High energy radiation therapy is associated with fast and thermal photoneutrons. Adequate shielding against the contaminant neutron has been recommended by IAEA and NCRP new protocols. Materials and methods The latest protocols released by the IAEA (safety report No. 47) and NCRP report No. 151 were used for the bunker designing calculations. MC method based upon data was also derived. Two bunkers using protocols and MC upon data were designed and discussed. Results From designed door's thickness, the door designed by the MC simulation and Wu–McGinley analytical method was closer in both BPE and lead thickness. In the case of the primary and secondary barriers, MC simulation resulted in 440.11 mm for the ordinary concrete, total concrete thickness of 1709 mm was required. Calculating the same parameters value with the recommended analytical methods resulted in 1762 mm for the required thickness using 445 mm as recommended by TVL for the concrete. Additionally, for the secondary barrier the thickness of 752.05 mm was obtained. Conclusion Our results showed MC simulation and the followed protocols recommendations in dose calculation are in good agreement in the radiation contamination dose calculation. Difference between the two analytical and MC simulation methods revealed that the application of only one method for the bunker design may lead to underestimation or overestimation in dose and shielding calculations. PMID:26900357

  8. Nonesterified fatty acid determination for functional lipidomics: comprehensive ultrahigh performance liquid chromatography-tandem mass spectrometry quantitation, qualification, and parameter prediction.

    PubMed

    Hellmuth, Christian; Weber, Martina; Koletzko, Berthold; Peissner, Wolfgang

    2012-02-07

    Despite their central importance for lipid metabolism, straightforward quantitative methods for determination of nonesterified fatty acid (NEFA) species are still missing. The protocol presented here provides unbiased quantitation of plasma NEFA species by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Simple deproteination of plasma in organic solvent solution yields high accuracy, including both the unbound and initially protein-bound fractions, while avoiding interferences from hydrolysis of esterified fatty acids from other lipid classes. Sample preparation is fast and nonexpensive, hence well suited for automation and high-throughput applications. Separation of isotopologic NEFA is achieved using ultrahigh-performance liquid chromatography (UPLC) coupled to triple quadrupole LC-MS/MS detection. In combination with automated liquid handling, total assay time per sample is less than 15 min. The analytical spectrum extends beyond readily available NEFA standard compounds by a regression model predicting all the relevant analytical parameters (retention time, ion path settings, and response factor) of NEFA species based on chain length and number of double bonds. Detection of 50 NEFA species and accurate quantification of 36 NEFA species in human plasma is described, the highest numbers ever reported for a LC-MS application. Accuracy and precision are within widely accepted limits. The use of qualifier ions supports unequivocal analyte verification. © 2012 American Chemical Society

  9. Current Technical Approaches for the Early Detection of Foodborne Pathogens: Challenges and Opportunities.

    PubMed

    Cho, Il-Hoon; Ku, Seockmo

    2017-09-30

    The development of novel and high-tech solutions for rapid, accurate, and non-laborious microbial detection methods is imperative to improve the global food supply. Such solutions have begun to address the need for microbial detection that is faster and more sensitive than existing methodologies (e.g., classic culture enrichment methods). Multiple reviews report the technical functions and structures of conventional microbial detection tools. These tools, used to detect pathogens in food and food homogenates, were designed via qualitative analysis methods. The inherent disadvantage of these analytical methods is the necessity for specimen preparation, which is a time-consuming process. While some literature describes the challenges and opportunities to overcome the technical issues related to food industry legal guidelines, there is a lack of reviews of the current trials to overcome technological limitations related to sample preparation and microbial detection via nano and micro technologies. In this review, we primarily explore current analytical technologies, including metallic and magnetic nanomaterials, optics, electrochemistry, and spectroscopy. These techniques rely on the early detection of pathogens via enhanced analytical sensitivity and specificity. In order to introduce the potential combination and comparative analysis of various advanced methods, we also reference a novel sample preparation protocol that uses microbial concentration and recovery technologies. This technology has the potential to expedite the pre-enrichment step that precedes the detection process.

  10. Prevalence of Malaria, Dengue, and Chikungunya Significantly Associated with Mosquito Breeding Sites

    PubMed Central

    Islam, Mohammad Nazrul; ZulKifle, Mohammad; Sherwani, Arish Mohammad Khan; Ghosh, Susanta Kumar; Tiwari, Satyanarayan

    2011-01-01

    Objectives: To observe the prevalence of malaria, dengue, and chikungunya and their association with mosquito breeding sites. Methods: The study was observational and analytical. A total of 162 houses and 670 subjects were observed during the study period. One hundred forty-two febrile patients were eligible for the study. After obtaining informed consent from all febrile patients, 140 blood samples were collected to diagnose malaria, dengue, and chikungunya. Larval samples were collected by the standard protocol that follows. Correlation of data was performed by Pearson correlation test. Results: Forty-seven blood samples were found positive: 33 for chikungunya, 3 for dengue, and 11 for malaria. Fifty-one out of 224 larval samples were found positive. Out of the 51 positive samples, 37 were positive for Aedes, 12 were positive for Anopheles, and two were positive for Culex larvae. Interpretation and Conclusion: Mosquito-borne fevers, especially malaria, dengue, and chikungunya, have shown a significant relationship with mosquito breeding sites. PMID:23610486

  11. ENVIRONMENTAL EVALUATION FOR UTILIZATION OF ASH IN SOIL STABILIZATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    David J. Hassett; Loreal V. Heebink

    2001-08-01

    The Minnesota Pollution Control Agency (MPCA) approved the use of coal ash in soil stabilization, indicating that environmental data needed to be generated. The overall project goal is to evaluate the potential for release of constituents into the environment from ash used in soil stabilization projects. Supporting objectives are: (1) To ensure sample integrity through implementation of a sample collection, preservation, and storage protocol to avoid analyte concentration or loss. (2) To evaluate the potential of each component (ash, soil, water) of the stabilized soil to contribute to environmental release of analytes of interest. (3) To use laboratory leaching methodsmore » to evaluate the potential for release of constituents to the environment. (4) To facilitate collection of and to evaluate samples from a field runoff demonstration effort. The results of this study indicated limited mobility of the coal combustion fly ash constituents in laboratory tests and the field runoff samples. The results presented support previous work showing little to negligible impact on water quality. This and past work indicates that soil stabilization is an environmentally beneficial CCB utilization application as encouraged by the U.S. Environmental Protection Agency. This project addressed the regulatory-driven environmental aspect of fly ash use for soil stabilization, but the demonstrated engineering performance and economic advantages also indicate that the use of CCBs in soil stabilization can and should become an accepted engineering option.« less

  12. Thawing as a critical pre-analytical step in the lipidomic profiling of plasma samples: New standardized protocol.

    PubMed

    Pizarro, Consuelo; Arenzana-Rámila, Irene; Pérez-del-Notario, Nuria; Pérez-Matute, Patricia; González-Sáiz, José María

    2016-03-17

    Lipid profiling is a promising tool for the discovery and subsequent identification of biomarkers associated with various diseases. However, data quality is quite dependent on the pre-analytical methods employed. To date, potential confounding factors that may affect lipid metabolite levels after the thawing of plasma for biomarker exploration studies have not been thoroughly evaluated. In this study, by means of experimental design methodology, we performed the first in-depth examination of the ways in which thawing conditions affect lipid metabolite levels. After the optimization stage, we concluded that temperature, sample volume and the thawing method were the determining factors that had to be exhaustively controlled in the thawing process to ensure the quality of biomarker discovery. Best thawing conditions were found to be: 4 °C, with 0.25 mL of human plasma and ultrasound (US) thawing. The new US proposed thawing method was quicker than the other methods we studied, allowed more features to be identified and increased the signal of the lipids. In view of its speed, efficiency and detectability, the US thawing method appears to be a simple, economical method for the thawing of plasma samples, which could easily be applied in clinical laboratories before lipid profiling studies. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Measuring xenon in human plasma and blood by gas chromatography/mass spectrometry.

    PubMed

    Thevis, Mario; Piper, Thomas; Geyer, Hans; Thomas, Andreas; Schaefer, Maximilian S; Kienbaum, Peter; Schänzer, Wilhelm

    2014-07-15

    Due to the favorable pharmacokinetic properties and minimal side effects of xenon, its use in modern anesthesia has been well accepted, and recent studies further demonstrated the intra- and postoperative neuro-, cardio-, and reno-protective action of the noble gas. Since the production of the hypoxia-inducible factor 1α (HIF-1α) and its downstream effector erythropoietin as well as noradrenalin reuptake inhibition have been found to play key roles in this context, the question arose as to whether the use of xenon is a matter for doping controls and preventive doping research. The aim of the present study was hence to evaluate whether the (ab)use of xenon can be detected from doping control samples with the instrumentation commonly available in sports drug testing laboratories. Plasma was saturated with xenon according to reported protocols, and the target analyte was measured by means of gas chromatography/time-of-flight and triple quadrupole mass spectrometry with headspace injection. Recording the accurate mass of three major xenon isotopes at m/z 128.9048, 130.9045 and 131.9042 allowed for the unequivocal identification of the analyte and the detection assay was characterized concerning limit of detection (LOD), intraday precision, and specificity as well as analyte recovery under different storage conditions. Xenon was detected in fortified plasma samples with detection limits of approximately 0.5 nmol/mL to 50 nmol/mL, depending on the type of mass spectrometer used. The method characteristics of intraday precision (coefficient of variation <20%) and specificity demonstrated the fitness-for-purpose of the analytical approach to unambiguously detect xenon at non-physiological concentrations in human plasma and blood. Eventually, authentic plasma and blood samples collected pre-, intra-, and post-operative (4, 8, and 24 h) were positively analyzed after storage for up to 30 h, and provided proof-of-concept for the developed assay. If relevant to doping controls, xenon can be determined from plasma and blood samples, i.e. common specimens of routine sports drug testing in the context of Athlete Biological Passport (ABP) analyses. Optimization of sampling and analytical procedures will allow the detection limit to be further improved and potentially enable accurate quantification of the anesthetic agent. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Evaluation of pre-analytical conditions and comparison of the performance of several digital PCR assays for the detection of major EGFR mutations in circulating DNA from non-small cell lung cancers: the CIRCAN_0 study

    PubMed Central

    Garcia, Jessica; Dusserre, Eric; Cheynet, Valérie; Bringuier, Pierre Paul; Brengle-Pesce, Karen; Wozny, Anne-Sophie; Rodriguez-Lafrasse, Claire; Freyer, Gilles; Brevet, Marie; Payen, Léa; Couraud, Sébastien

    2017-01-01

    Non invasive somatic detection assays are suitable for repetitive tumor characterization or for detecting the appearance of somatic resistance during lung cancer. Molecular diagnosis based on circulating free DNA (cfDNA) offers the opportunity to track the genomic evolution of the tumor, and was chosen to assess the molecular profile of several EGFR alterations, including deletions in exon 19 (delEX19), the L858R substitution on exon 21 and the EGFR resistance mutation T790M on exon 20. Our study aimed at determining optimal pre-analytical conditions and EGFR mutation detection assays for analyzing cfDNA using the picoliter-droplet digital polymerase chain reaction (ddPCR) assay. Within the framework of the CIRCAN project set-up at the Lyon University Hospital, plasma samples were collected to establish a pre-analytical and analytical workflow of cfDNA analysis. We evaluated all of the steps from blood sampling to mutation detection output, including shipping conditions (4H versus 24H in EDTA tubes), the reproducibility of cfDNA extraction, the specificity/sensitivity of ddPCR (using external controls), and the comparison of different PCR assays for the detection of the three most important EGFR hotspots, which highlighted the increased sensitivity of our in-house primers/probes. Hence, we have described a new protocol facilitating the molecular detection of somatic mutations in cancer patients from liquid biopsies, improving their diagnosis and introducing a less traumatic monitoring system during tumor progression. PMID:29152135

  15. Review of sample preparation strategies for MS-based metabolomic studies in industrial biotechnology.

    PubMed

    Causon, Tim J; Hann, Stephan

    2016-09-28

    Fermentation and cell culture biotechnology in the form of so-called "cell factories" now play an increasingly significant role in production of both large (e.g. proteins, biopharmaceuticals) and small organic molecules for a wide variety of applications. However, associated metabolic engineering optimisation processes relying on genetic modification of organisms used in cell factories, or alteration of production conditions remain a challenging undertaking for improving the final yield and quality of cell factory products. In addition to genomic, transcriptomic and proteomic workflows, analytical metabolomics continues to play a critical role in studying detailed aspects of critical pathways (e.g. via targeted quantification of metabolites), identification of biosynthetic intermediates, and also for phenotype differentiation and the elucidation of previously unknown pathways (e.g. via non-targeted strategies). However, the diversity of primary and secondary metabolites and the broad concentration ranges encompassed during typical biotechnological processes means that simultaneous extraction and robust analytical determination of all parts of interest of the metabolome is effectively impossible. As the integration of metabolome data with transcriptome and proteome data is an essential goal of both targeted and non-targeted methods addressing production optimisation goals, additional sample preparation steps beyond necessary sampling, quenching and extraction protocols including clean-up, analyte enrichment, and derivatisation are important considerations for some classes of metabolites, especially those present in low concentrations or exhibiting poor stability. This contribution critically assesses the potential of current sample preparation strategies applied in metabolomic studies of industrially-relevant cell factory organisms using mass spectrometry-based platforms primarily coupled to liquid-phase sample introduction (i.e. flow injection, liquid chromatography, or capillary electrophoresis). Particular focus is placed on the selectivity and degree of enrichment attainable, as well as demands of speed, absolute quantification, robustness and, ultimately, consideration of fully-integrated bioanalytical solutions to optimise sample handling and throughput. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Development of characterization protocol for mixed liquid radioactive waste classification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zakaria, Norasalwa, E-mail: norasalwa@nuclearmalaysia.gov.my; Wafa, Syed Asraf; Wo, Yii Mei

    2015-04-29

    Mixed liquid organic waste generated from health-care and research activities containing tritium, carbon-14, and other radionuclides posed specific challenges in its management. Often, these wastes become legacy waste in many nuclear facilities and being considered as ‘problematic’ waste. One of the most important recommendations made by IAEA is to perform multistage processes aiming at declassification of the waste. At this moment, approximately 3000 bottles of mixed liquid waste, with estimated volume of 6000 litres are currently stored at the National Radioactive Waste Management Centre, Malaysia and some have been stored for more than 25 years. The aim of this studymore » is to develop a characterization protocol towards reclassification of these wastes. The characterization protocol entails waste identification, waste screening and segregation, and analytical radionuclides profiling using various analytical procedures including gross alpha/ gross beta, gamma spectrometry, and LSC method. The results obtained from the characterization protocol are used to establish criteria for speedy classification of the waste.« less

  17. The combination of four analytical methods to explore skeletal muscle metabolomics: Better coverage of metabolic pathways or a marketing argument?

    PubMed

    Bruno, C; Patin, F; Bocca, C; Nadal-Desbarats, L; Bonnier, F; Reynier, P; Emond, P; Vourc'h, P; Joseph-Delafont, K; Corcia, P; Andres, C R; Blasco, H

    2018-01-30

    Metabolomics is an emerging science based on diverse high throughput methods that are rapidly evolving to improve metabolic coverage of biological fluids and tissues. Technical progress has led researchers to combine several analytical methods without reporting the impact on metabolic coverage of such a strategy. The objective of our study was to develop and validate several analytical techniques (mass spectrometry coupled to gas or liquid chromatography and nuclear magnetic resonance) for the metabolomic analysis of small muscle samples and evaluate the impact of combining methods for more exhaustive metabolite covering. We evaluated the muscle metabolome from the same pool of mouse muscle samples after 2 metabolite extraction protocols. Four analytical methods were used: targeted flow injection analysis coupled with mass spectrometry (FIA-MS/MS), gas chromatography coupled with mass spectrometry (GC-MS), liquid chromatography coupled with high-resolution mass spectrometry (LC-HRMS), and nuclear magnetic resonance (NMR) analysis. We evaluated the global variability of each compound i.e., analytical (from quality controls) and extraction variability (from muscle extracts). We determined the best extraction method and we reported the common and distinct metabolites identified based on the number and identity of the compounds detected with low analytical variability (variation coefficient<30%) for each method. Finally, we assessed the coverage of muscle metabolic pathways obtained. Methanol/chloroform/water and water/methanol were the best extraction solvent for muscle metabolome analysis by NMR and MS, respectively. We identified 38 metabolites by nuclear magnetic resonance, 37 by FIA-MS/MS, 18 by GC-MS, and 80 by LC-HRMS. The combination led us to identify a total of 132 metabolites with low variability partitioned into 58 metabolic pathways, such as amino acid, nitrogen, purine, and pyrimidine metabolism, and the citric acid cycle. This combination also showed that the contribution of GC-MS was low when used in combination with other mass spectrometry methods and nuclear magnetic resonance to explore muscle samples. This study reports the validation of several analytical methods, based on nuclear magnetic resonance and several mass spectrometry methods, to explore the muscle metabolome from a small amount of tissue, comparable to that obtained during a clinical trial. The combination of several techniques may be relevant for the exploration of muscle metabolism, with acceptable analytical variability and overlap between methods However, the difficult and time-consuming data pre-processing, processing, and statistical analysis steps do not justify systematically combining analytical methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Raman Spectroscopic Analysis of Geological and Biogeological Specimens of Relevance to the ExoMars Mission

    PubMed Central

    Edwards, Howell G.M.; Ingley, Richard; Parnell, John; Vítek, Petr; Jehlička, Jan

    2013-01-01

    Abstract A novel miniaturized Raman spectrometer is scheduled to fly as part of the analytical instrumentation package on an ESA remote robotic lander in the ESA/Roscosmos ExoMars mission to search for evidence for extant or extinct life on Mars in 2018. The Raman spectrometer will be part of the first-pass analytical stage of the sampling procedure, following detailed surface examination by the PanCam scanning camera unit on the ExoMars rover vehicle. The requirements of the analytical protocol are stringent and critical; this study represents a laboratory blind interrogation of specimens that form a list of materials that are of relevance to martian exploration and at this stage simulates a test of current laboratory instrumentation to highlight the Raman technique strengths and possible weaknesses that may be encountered in practice on the martian surface and from which future studies could be formulated. In this preliminary exercise, some 10 samples that are considered terrestrial representatives of the mineralogy and possible biogeologically modified structures that may be identified on Mars have been examined with Raman spectroscopy, and conclusions have been drawn about the viability of the unambiguous spectral identification of biomolecular life signatures. It is concluded that the Raman spectroscopic technique does indeed demonstrate the capability to identify biomolecular signatures and the mineralogy in real-world terrestrial samples with a very high degree of success without any preconception being made about their origin and classification. Key Words: Biosignatures—Mars Exploration Rovers—Raman spectroscopy—Search for life (biosignatures)—Planetary instrumentation. Astrobiology 13, 543–549. PMID:23758166

  19. Optimizing direct amplification of forensic commercial kits for STR determination.

    PubMed

    Caputo, M; Bobillo, M C; Sala, A; Corach, D

    2017-04-01

    Direct DNA amplification in forensic genotyping reduces analytical time when large sample sets are being analyzed. The amplification success depends mainly upon two factors: on one hand, the PCR chemistry and, on the other, the type of solid substrate where the samples are deposited. We developed a workflow strategy aiming to optimize times and cost when starting from blood samples spotted onto diverse absorbent substrates. A set of 770 blood samples spotted onto Blood cards, Whatman ® 3 MM paper, FTA™ Classic cards, and Whatman ® Grade 1 was analyzed by a unified working strategy including a low-cost pre-treatment, a PCR amplification volume scale-down, and the use of the 3500 Genetic Analyzer as the analytical platform. Samples were analyzed using three different commercial multiplex STR direct amplification kits. The efficiency of the strategy was evidenced by a higher percentage of high-quality profiles obtained (over 94%), a reduced number of re-injections (average 3.2%), and a reduced amplification failure rate (lower than 5%). Average peak height ratio among different commercial kits was 0.91, and the intra-locus balance showed values ranging from 0.92 to 0.94. A comparison with previously reported results was performed demonstrating the efficiency of the proposed modifications. The protocol described herein showed high performance, producing optimal quality profiles, and being both time and cost effective. Copyright © 2017 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  20. Development of Gold Standard Ion-Selective Electrode-Based Methods for Fluoride Analysis

    PubMed Central

    Martínez-Mier, E.A.; Cury, J.A.; Heilman, J.R.; Katz, B.P.; Levy, S.M.; Li, Y.; Maguire, A.; Margineda, J.; O’Mullane, D.; Phantumvanit, P.; Soto-Rojas, A.E.; Stookey, G.K.; Villa, A.; Wefel, J.S.; Whelton, H.; Whitford, G.M.; Zero, D.T.; Zhang, W.; Zohouri, V.

    2011-01-01

    Background/Aims: Currently available techniques for fluoride analysis are not standardized. Therefore, this study was designed to develop standardized methods for analyzing fluoride in biological and nonbiological samples used for dental research. Methods A group of nine laboratories analyzed a set of standardized samples for fluoride concentration using their own methods. The group then reviewed existing analytical techniques for fluoride analysis, identified inconsistencies in the use of these techniques and conducted testing to resolve differences. Based on the results of the testing undertaken to define the best approaches for the analysis, the group developed recommendations for direct and microdiffusion methods using the fluoride ion-selective electrode. Results Initial results demonstrated that there was no consensus regarding the choice of analytical techniques for different types of samples. Although for several types of samples, the results of the fluoride analyses were similar among some laboratories, greater differences were observed for saliva, food and beverage samples. In spite of these initial differences, precise and true values of fluoride concentration, as well as smaller differences between laboratories, were obtained once the standardized methodologies were used. Intraclass correlation coefficients ranged from 0.90 to 0.93, for the analysis of a certified reference material, using the standardized methodologies. Conclusion The results of this study demonstrate that the development and use of standardized protocols for F analysis significantly decreased differences among laboratories and resulted in more precise and true values. PMID:21160184

  1. Dried haematic microsamples and LC-MS/MS for the analysis of natural and synthetic cannabinoids.

    PubMed

    Protti, Michele; Rudge, James; Sberna, Angelo Eliseo; Gerra, Gilberto; Mercolini, Laura

    2017-02-15

    Synthetic cannabinoids are new psychoactive substances (NPS) with similar effects when compared to natural ones found in Cannabis derivatives. They have rapidly integrated into the illicit market, often sold as alternatives under international control. The need to identify and quantify an unprecedented and growing number of new compounds represents a unique challenge for toxicological, forensic and anti-doping analysis. Dried blood spots have been used within the bioanalytical framework in place of plasma or serum, in order to reduce invasiveness, lower sample size, simplify handling, storage and shipping of samples and to facilitate home-based and on-field applications. However, DBS implementation has been limited mainly by concerns related to haematocrit effect on method accuracy. Volumetric absorptive microsampling (VAMS™), a second generation dried miniaturized sampling technology, has been developed just in order to eliminate haematocrit effect, thus providing accurate sampling but still granting feasible sample processing. An original LC-MS/MS method was herein developed and validated for the analysis of THC and its 2 main metabolites, together with 10 representative synthetic cannabinoids in both DBS and VAMS dried microsamples. The ultimate goal of this work is to provide highly innovative DBS and VAMS analytical protocols, whose performances were extensively optimized and compared, in order to provide effective and alternative tools that can be applied for natural and synthetic cannabinoid determination, in place of classical analytical strategies. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. A rapid and reliable method for Pb isotopic analysis of peat and lichens by laser ablation-quadrupole-inductively coupled plasma-mass spectrometry for biomonitoring and sample screening.

    PubMed

    Kylander, M E; Weiss, D J; Jeffries, T E; Kober, B; Dolgopolova, A; Garcia-Sanchez, R; Coles, B J

    2007-01-16

    An analytical protocol for rapid and reliable laser ablation-quadrupole (LA-Q)- and multi-collector (MC-) inductively coupled plasma-mass spectrometry (ICP-MS) analysis of Pb isotope ratios ((207)Pb/(206)Pb and (208)Pb/(206)Pb) in peats and lichens is developed. This technique is applicable to source tracing atmospheric Pb deposition in biomonitoring studies and sample screening. Reference materials and environmental samples were dry ashed and pressed into pellets for introduction by laser ablation. No binder was used to reduce contamination. LA-MC-ICP-MS internal and external precisions were <1.1% and <0.3%, respectively, on both (207)Pb/(206)Pb and (208)Pb/(206)Pb ratios. LA-Q-ICP-MS internal precisions on (207)Pb/(206)Pb and (208)Pb/(206)Pb ratios were lower with values for the different sample sets <14.3% while external precisions were <2.9%. The level of external precision acquired in this study is high enough to distinguish between most modern Pb sources. LA-MC-ICP-MS measurements differed from thermal ionisation mass spectrometry (TIMS) values by 1% or less while the accuracy obtained using LA-Q-ICP-MS compared to solution MC-ICP-MS was 3.1% or better using a run bracketing (RB) mass bias correction method. Sample heterogeneity and detector switching when measuring (208)Pb by Q-ICP-MS are identified as sources of reduced analytical performance.

  3. Universality of Generalized Bunching and Efficient Assessment of Boson Sampling.

    PubMed

    Shchesnovich, V S

    2016-03-25

    It is found that identical bosons (fermions) show a generalized bunching (antibunching) property in linear networks: the absolute maximum (minimum) of the probability that all N input particles are detected in a subset of K output modes of any nontrivial linear M-mode network is attained only by completely indistinguishable bosons (fermions). For fermions K is arbitrary; for bosons it is either (i) arbitrary for only classically correlated bosons or (ii) satisfies K≥N (or K=1) for arbitrary input states of N particles. The generalized bunching allows us to certify in a polynomial in N number of runs that a physical device realizing boson sampling with an arbitrary network operates in the regime of full quantum coherence compatible only with completely indistinguishable bosons. The protocol needs only polynomial classical computations for the standard boson sampling, whereas an analytic formula is available for the scattershot version.

  4. Data on Mercury in Water, Bed Sediment, and Fish from Streams Across the United States, 1998-2005

    USGS Publications Warehouse

    Bauch, Nancy J.; Chasar, Lia C.; Scudder, Barbara C.; Moran, Patrick W.; Hitt, Kerie J.; Brigham, Mark E.; Lutz, Michelle A.; Wentz, Dennis A.

    2009-01-01

    The U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) and Toxic Substances Hydrology Programs conducted the National Mercury Pilot Study in 1998 to examine relations of mercury (Hg) in water, bed sediment and fish in streams across the United States, including Alaska and Hawaii. Water and bed-sediment samples were analyzed for total Hg (THg), methylmercury (MeHg), and other constituents; fish were analyzed for THg. Similar sampling was conducted at additional streams across the country in 2002 and 2004-05. This report summarizes sample collection and processing protocols, analytical methods, environmental data, and quality-assurance data for stream water, bed sediment, and fish for these national studies. To extend the geographic coverage of the data, this report also includes four regional USGS Hg studies conducted during 1998-2001 and 2004. The environmental data for these national and regional Hg studies are provided in an electronic format.

  5. ISOS-3 Inter-Laboratory Collaboration Focused on the Stability of a Variety of Organic Photovoltaic Devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanenbaum, D. M.; Hermenau, M.; Voroshazi, E.

    2012-02-07

    Seven distinct sets (n {>=} 12) of state of the art organic photovoltaic devices were prepared by leading research laboratories in a collaboration planned at the Third International Summit on Organic Photovoltaic Stability (ISOS-3). All devices were shipped to RISO DTU and characterized simultaneously up to 1830 h in accordance with established ISOS-3 protocols under three distinct illumination conditions: accelerated full sun simulation; low level indoor fluorescent lighting; and dark storage with daily measurement under full sun simulation. Three nominally identical devices were used in each experiment both to provide an assessment of the homogeneity of the samples and tomore » distribute samples for a variety of post soaking analytical measurements at six distinct laboratories enabling comparison at various stages in the degradation of the devices. Over 100 devices with more than 300 cells were used in the study. We present here design and fabrication details for the seven device sets, benefits and challenges associated with the unprecedented size of the collaboration, characterization protocols, and results both on individual device stability and uniformity of device sets, in the three illumination conditions.« less

  6. Use of a Deuterated Internal Standard with Pyrolysis-GC/MS Dimeric Marker Analysis to Quantify Tire Tread Particles in the Environment

    PubMed Central

    Unice, Kenneth M.; Kreider, Marisa L.; Panko, Julie M.

    2012-01-01

    Pyrolysis(pyr)-GC/MS analysis of characteristic thermal decomposition fragments has been previously used for qualitative fingerprinting of organic sources in environmental samples. A quantitative pyr-GC/MS method based on characteristic tire polymer pyrolysis products was developed for tread particle quantification in environmental matrices including soil, sediment, and air. The feasibility of quantitative pyr-GC/MS analysis of tread was confirmed in a method evaluation study using artificial soil spiked with known amounts of cryogenically generated tread. Tread concentration determined by blinded analyses was highly correlated (r2 ≥ 0.88) with the known tread spike concentration. Two critical refinements to the initial pyrolysis protocol were identified including use of an internal standard and quantification by the dimeric markers vinylcyclohexene and dipentene, which have good specificity for rubber polymer with no other appreciable environmental sources. A novel use of deuterated internal standards of similar polymeric structure was developed to correct the variable analyte recovery caused by sample size, matrix effects, and ion source variability. The resultant quantitative pyr-GC/MS protocol is reliable and transferable between laboratories. PMID:23202830

  7. Postnatal gestational age estimation using newborn screening blood spots: a proposed validation protocol

    PubMed Central

    Murphy, Malia S Q; Hawken, Steven; Atkinson, Katherine M; Milburn, Jennifer; Pervin, Jesmin; Gravett, Courtney; Stringer, Jeffrey S A; Rahman, Anisur; Lackritz, Eve; Chakraborty, Pranesh; Wilson, Kumanan

    2017-01-01

    Background Knowledge of gestational age (GA) is critical for guiding neonatal care and quantifying regional burdens of preterm birth. In settings where access to ultrasound dating is limited, postnatal estimates are frequently used despite the issues of accuracy associated with postnatal approaches. Newborn metabolic profiles are known to vary by severity of preterm birth. Recent work by our group and others has highlighted the accuracy of postnatal GA estimation algorithms derived from routinely collected newborn screening profiles. This protocol outlines the validation of a GA model originally developed in a North American cohort among international newborn cohorts. Methods Our primary objective is to use blood spot samples collected from infants born in Zambia and Bangladesh to evaluate our algorithm’s capacity to correctly classify GA within 1, 2, 3 and 4 weeks. Secondary objectives are to 1) determine the algorithm's accuracy in small-for-gestational-age and large-for-gestational-age infants, 2) determine its ability to correctly discriminate GA of newborns across dichotomous thresholds of preterm birth (≤34 weeks, <37 weeks GA) and 3) compare the relative performance of algorithms derived from newborn screening panels including all available analytes and those restricted to analyte subsets. The study population will consist of infants born to mothers already enrolled in one of two preterm birth cohorts in Lusaka, Zambia, and Matlab, Bangladesh. Dried blood spot samples will be collected and sent for analysis in Ontario, Canada, for model validation. Discussion This study will determine the validity of a GA estimation algorithm across ethnically diverse infant populations and assess population specific variations in newborn metabolic profiles. PMID:29104765

  8. A computer program for geochemical analysis of acid-rain and other low-ionic-strength, acidic waters

    USGS Publications Warehouse

    Johnsson, P.A.; Lord, D.G.

    1987-01-01

    ARCHEM, a computer program written in FORTRAN 77, is designed primarily for use in the routine geochemical interpretation of low-ionic-strength, acidic waters. On the basis of chemical analyses of the water, and either laboratory or field determinations of pH, temperature, and dissolved oxygen, the program calculates the equilibrium distribution of major inorganic aqueous species and of inorganic aluminum complexes. The concentration of the organic anion is estimated from the dissolved organic concentration. Ionic ferrous iron is calculated from the dissolved oxygen concentration. Ionic balances and comparisons of computed with measured specific conductances are performed as checks on the analytical accuracy of chemical analyses. ARCHEM may be tailored easily to fit different sampling protocols, and may be run on multiple sample analyses. (Author 's abstract)

  9. Protocol for Future Amino Acid Analyses of Samples Returned by the Stardust Mission

    NASA Technical Reports Server (NTRS)

    Glavin, D. P.; Doty, J. H., III; Matrajt, G.; Dworkin, J. P.

    2006-01-01

    We have demonstrated that LC-ToF-MS coupled with UV fluorescence detection is a powerful tool for the detection of amino acids in meteorite extracts. Using this new analytical technique we were able to identify the extraterrestrial amino acid AIB extracted from fifteen 20 micron sized Murchison meteorite grains. We found that the amino acid contamination levels in Stardust aerogels was much lower than the levels observed in the Murchison meteorite. In addition, the alpha-dialkyl amino acids AIB and isovaline which are the most abundant amino acids in Murchison were not detected in the aerogel above blank levels. We are currently integrating LIF detection capability to our existing nanoflow LC-ToF-MS for enhanced sensitivity required for the analysis of amino acids in Stardust samples.

  10. High‐precision determination of lithium and magnesium isotopes utilising single column separation and multi‐collector inductively coupled plasma mass spectrometry

    PubMed Central

    Misra, Sambuddha; Lloyd, Nicholas; Elderfield, Henry; Bickle, Mike J.

    2017-01-01

    Rationale Li and Mg isotopes are increasingly used as a combined tool within the geosciences. However, established methods require separate sample purification protocols utilising several column separation procedures. This study presents a single‐step cation‐exchange method for quantitative separation of trace levels of Li and Mg from multiple sample matrices. Methods The column method utilises the macro‐porous AGMP‐50 resin and a high‐aspect ratio column, allowing quantitative separation of Li and Mg from natural waters, sediments, rocks and carbonate matrices following the same elution protocol. High‐precision isotope determination was conducted by multi‐collector inductively coupled plasma mass spectrometry (MC‐ICPMS) on the Thermo Scientific™ NEPTUNE Plus™ fitted with 1013 Ω amplifiers which allow accurate and precise measurements at ion beams ≤0.51 V. Results Sub‐nanogram Li samples (0.3–0.5 ng) were regularly separated (yielding Mg masses of 1–70 μg) using the presented column method. The total sample consumption during isotopic analysis is <0.5 ng Li and <115 ng Mg with long‐term external 2σ precisions of ±0.39‰ for δ7Li and ±0.07‰ for δ26Mg. The results for geological reference standards and seawater analysed by our method are in excellent agreement with published values despite the order of magnitude lower sample consumption. Conclusions The possibility of eluting small sample masses and the low analytical sample consumption make this method ideal for samples of limited mass or low Li concentration, such as foraminifera, mineral separates or dilute river waters. PMID:29078008

  11. ELISA: Methods and Protocols

    USDA-ARS?s Scientific Manuscript database

    The antibody is central to the performance of an ELISA providing the basis of analyte selection and detection. It is the interaction of antibody with analyte under defined conditions that dictates the outcome of the ELISA and deviations in those conditions will impact assay performance. The aim of...

  12. Analytical Protocol (GC/ECNIMS) for OSWER's Response to OIG Report (2005-P-00022) on Toxaphene Analysis

    EPA Science Inventory

    The research approached the large number and complexity of the analytes as four separate groups: technical toxaphene, toxaphene congeners (eight in number), chlordane, and organochlorine pesticides. This approach was advantageous because it eliminated potential interferences amon...

  13. Sample preparation combined with electroanalysis to improve simultaneous determination of antibiotics in animal derived food samples.

    PubMed

    da Silva, Wesley Pereira; de Oliveira, Luiz Henrique; Santos, André Luiz Dos; Ferreira, Valdir Souza; Trindade, Magno Aparecido Gonçalves

    2018-06-01

    A procedure based on liquid-liquid extraction (LLE) and phase separation using magnetically stirred salt-induced high-temperature liquid-liquid extraction (PS-MSSI-HT-LLE) was developed to extract and pre-concentrate ciprofloxacin (CIPRO) and enrofloxacin (ENRO) from animal food samples before electroanalysis. Firstly, simple LLE was used to extract the fluoroquinolones (FQs) from animal food samples, in which dilution was performed to reduce interference effects to below a tolerable threshold. Then, adapted PS-MSSI-HT-LLE protocols allowed re-extraction and further pre-concentration of target analytes in the diluted acid samples for simultaneous electrochemical quantification at low concentration levels. To improve the peak separation, in simultaneous detection, a baseline-corrected second-order derivative approach was processed. These approaches allowed quantification of target FQs from animal food samples spiked at levels of 0.80 to 2.00 µmol L -1 in chicken meat, with recovery values always higher than 80.5%, as well as in milk samples spiked at 4.00 µmol L -1 , with recovery values close to 70.0%. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. A Validated Method for the Quality Control of Andrographis paniculata Preparations.

    PubMed

    Karioti, Anastasia; Timoteo, Patricia; Bergonzi, Maria Camilla; Bilia, Anna Rita

    2017-10-01

    Andrographis paniculata is a herbal drug of Asian traditional medicine largely employed for the treatment of several diseases. Recently, it has been introduced in Europe for the prophylactic and symptomatic treatment of common cold and as an ingredient of dietary supplements. The active principles are diterpenes with andrographolide as the main representative. In the present study, an analytical protocol was developed for the determination of the main constituents in the herb and preparations of A. paniculata . Three different extraction protocols (methanol extraction using a modified Soxhlet procedure, maceration under ultrasonication, and decoction) were tested. Ultrasonication achieved the highest content of analytes. HPLC conditions were optimized in terms of solvent mixtures, time course, and temperature. A reversed phase C18 column eluted with a gradient system consisting of acetonitrile and acidified water and including an isocratic step at 30 °C was used. The HPLC method was validated for linearity, limits of quantitation and detection, repeatability, precision, and accuracy. The overall method was validated for precision and accuracy over at least three different concentration levels. Relative standard deviation was less than 1.13%, whereas recovery was between 95.50% and 97.19%. The method also proved to be suitable for the determination of a large number of commercial samples and was proposed to the European Pharmacopoeia for the quality control of Andrographidis herba. Georg Thieme Verlag KG Stuttgart · New York.

  15. Comparative Analytical Utility of DNA Derived from Alternative Human Specimens for Molecular Autopsy and Diagnostics

    PubMed Central

    Klassen, Tara L.; von Rüden, Eva-Lotta; Drabek, Janice; Noebels, Jeffrey L.; Goldman, Alica M.

    2013-01-01

    Genetic testing and research have increased the demand for high-quality DNA that has traditionally been obtained by venipuncture. However, venous blood collection may prove difficult in special populations and when large-scale specimen collection or exchange is prerequisite for international collaborative investigations. Guthrie/FTA card–based blood spots, buccal scrapes, and finger nail clippings are DNA-containing specimens that are uniquely accessible and thus attractive as alternative tissue sources (ATS). The literature details a variety of protocols for extraction of nucleic acids from a singular ATS type, but their utility has not been systematically analyzed in comparison with conventional sources such as venous blood. Additionally, the efficacy of each protocol is often equated with the overall nucleic acid yield but not with the analytical performance of the DNA during mutation detection. Together with a critical in-depth literature review of published extraction methods, we developed and evaluated an all-inclusive approach for serial, systematic, and direct comparison of DNA utility from multiple biological samples. Our results point to the often underappreciated value of these alternative tissue sources and highlight ways to maximize the ATS-derived DNA for optimal quantity, quality, and utility as a function of extraction method. Our comparative analysis clarifies the value of ATS in genomic analysis projects for population-based screening, diagnostics, molecular autopsy, medico-legal investigations, or multi-organ surveys of suspected mosaicisms. PMID:22796560

  16. Evaluation of the highly sensitive Roche thyroglobulin II assay and establishment of a reference limit for thyroglobulin-negative patient samples.

    PubMed

    Rotteveel-de Groot, Dorien M; Ross, H Alec; Janssen, Marcel J R; Netea-Maier, Romana T; Oosting, Janine D; Sweep, Fred C G J; van Herwaarden, Antonius E

    2016-08-01

    Thyroglobulin (Tg) measurements are used to monitor for residual thyroid tissue in patients with differentiated thyroid cancer (DTC) after thyroidectomy and radioiodine ablative therapy. In recent years highly sensitive Tg assays have been developed. In this study the analytical performance of the new Roche Elecsys Tg II assay was evaluated and compared with the well documented Access2 Tg assay (Beckman-Coulter). Analytical performance was examined using various Clinical and Laboratory Standards Institute (CLSI) evaluation protocols. Tg negative patient sera were used to establish an upper reference limit (URL) for the Elecsys Tg II assay. Non-linearity, drift and carry-over according to CLSI EP10 and EP6 in a measuring range of 0.04-500 ng/mL were non-significant. Total precision according to CLSI EP5 was 10% at a Tg concentration of 0.08 ng/mL. A patient serum comparison performed according to a modified CLSI EP9 protocol showed a significant difference of a factor of approximately 1.4, despite using an identical CRM calibrator. The Elecsys Tg II assay measured Tg with a two-fold higher sensitivity than the Access2 assay. Finally, using human sera without Tg, an URL of 0.05 ng/mL was determined. In our hands the highly sensitive Elecsys Tg II assay shows a good analytical performance and a higher sensitivity compared to the Access2 Tg assay. An URL of 0.05 ng/mL for the Elecsys Tg II assay was determined which may improve the clinical utility of the assay for the detection of residual DTC or disease recurrence.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Part, Florian; Zecha, Gudrun; Causon, Tim

    Highlights: • First review on detection of nanomaterials in complex waste samples. • Focus on nanoparticles in solid, liquid and gaseous waste samples. • Summary of current applicable methods for nanowaste detection and characterisation. • Limitations and challenges of characterisation of nanoparticles in waste. - Abstract: Engineered nanomaterials (ENMs) are already extensively used in diverse consumer products. Along the life cycle of a nano-enabled product, ENMs can be released and subsequently accumulate in the environment. Material flow models also indicate that a variety of ENMs may accumulate in waste streams. Therefore, a new type of waste, so-called nanowaste, is generatedmore » when end-of-life ENMs and nano-enabled products are disposed of. In terms of the precautionary principle, environmental monitoring of end-of-life ENMs is crucial to allow assessment of the potential impact of nanowaste on our ecosystem. Trace analysis and quantification of nanoparticulate species is very challenging because of the variety of ENM types that are used in products and low concentrations of nanowaste expected in complex environmental media. In the framework of this paper, challenges in nanowaste characterisation and appropriate analytical techniques which can be applied to nanowaste analysis are summarised. Recent case studies focussing on the characterisation of ENMs in waste streams are discussed. Most studies aim to investigate the fate of nanowaste during incineration, particularly considering aerosol measurements; whereas, detailed studies focusing on the potential release of nanowaste during waste recycling processes are currently not available. In terms of suitable analytical methods, separation techniques coupled to spectrometry-based methods are promising tools to detect nanowaste and determine particle size distribution in liquid waste samples. Standardised leaching protocols can be applied to generate soluble fractions stemming from solid wastes, while micro- and ultrafiltration can be used to enrich nanoparticulate species. Imaging techniques combined with X-ray-based methods are powerful tools for determining particle size, morphology and screening elemental composition. However, quantification of nanowaste is currently hampered due to the problem to differentiate engineered from naturally-occurring nanoparticles. A promising approach to face these challenges in nanowaste characterisation might be the application of nanotracers with unique optical properties, elemental or isotopic fingerprints. At present, there is also a need to develop and standardise analytical protocols regarding nanowaste sampling, separation and quantification. In general, more experimental studies are needed to examine the fate and transport of ENMs in waste streams and to deduce transfer coefficients, respectively to develop reliable material flow models.« less

  18. Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Addleman, Raymond S.; Naes, Benjamin E.; McNamara, Bruce K.

    The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmentalmore » sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for evaluation). • Explored improvements to carbonate-peroxide rapid uranium extraction chemistry. • Evaluated new sampling materials and methods (in collaboration with ORNL). • Demonstrated successful ES extractions from standard and novel swipes for a wide range uranium compounds of interest including UO 2F 2 and UO 2(NO 3) 2, U 3O 8 and uranium ore concentrate. • Completed initial discussions with commercial suppliers of PTFE swipe materials. • Submitted one manuscript for publication. Two additional drafts are being prepared. Principal progress and accomplishments on Task 2, Optimize Materials and Methods for Direct SIMS Environmental Sample Analysis, are listed below. • Designed a SIMS swipe sample holder that retrofits into existing equipment and provides simple, effective, and rapid mounting of ES samples for direct assay while enabling automation and laboratory integration. • Identified preferred conductive sampling materials with better performance characteristics. • Ran samples on the new PNNL NWAL equivalent Cameca 1280 SIMS system. • Obtained excellent agreement between isotopic ratios for certified materials and direct SIMS assay of very low levels of LEU and HEU UO 2F 2 particles on carbon fiber sampling material. Sample activities range from 1 to 500 CPM (uranium mass on sample is dependent upon specific isotope ratio but is frequently in the subnanogram range). • Found that the presence of the UF molecular ions, as measured by SIMS, provides chemical information about the particle that is separate from the uranium isotopics and strongly suggests that those particles originated from an UF6 enrichment activity. • Submitted one manuscript for publication. Another manuscript is in preparation.« less

  19. SCIENCE MISCONDUCT ACTIVITIES IN ENVIRONMENTAL ANALYSIS - FRAUD DETECTION IN GC/MS/ICP ACTIVITIES

    EPA Science Inventory

    Contracted laboratories perform a vast number of routine and special analytical services that are the foundation of decisions upon which rests the fate of the environment. Guiding these laboratories in the generation of environmental data has been the analytical protocols and th...

  20. A Constrained and Versioned Data Model for TEAM Data

    NASA Astrophysics Data System (ADS)

    Andelman, S.; Baru, C.; Chandra, S.; Fegraus, E.; Lin, K.

    2009-04-01

    The objective of the Tropical Ecology Assessment and Monitoring Network (www.teamnetwork.org) is "To generate real time data for monitoring long-term trends in tropical biodiversity through a global network of TEAM sites (i.e. field stations in tropical forests), providing an early warning system on the status of biodiversity to effectively guide conservation action". To achieve this, the TEAM Network operates by collecting data via standardized protocols at TEAM Sites. The standardized TEAM protocols include the Climate, Vegetation and Terrestrial Vertebrate Protocols. Some sites also implement additional protocols. There are currently 7 TEAM Sites with plans to grow the network to 15 by June 30, 2009 and 50 TEAM Sites by the end of 2010. At each TEAM Site, data is gathered as defined by the protocols and according to a predefined sampling schedule. The TEAM data is organized and stored in a database based on the TEAM spatio-temporal data model. This data model is at the core of the TEAM Information System - it consumes and executes spatio-temporal queries, and analytical functions that are performed on TEAM data, and defines the object data types, relationships and operations that maintain database integrity. The TEAM data model contains object types including types for observation objects (e.g. bird, butterfly and trees), sampling unit, person, role, protocol, site and the relationship of these object types. Each observation data record is a set of attribute values of an observation object and is always associated with a sampling unit, an observation timestamp or time interval, a versioned protocol and data collectors. The operations on the TEAM data model can be classified as read operations, insert operations and update operations. Following are some typical operations: The operation get(site, protocol, [sampling unit block, sampling unit,] start time, end time) returns all data records using the specified protocol and collected at the specified site, block, sampling unit and time range. The operation insertSamplingUnit(sampling unit, site, protocol) saves a new sampling unit into the data model and links it with the site and protocol. The operation updateSampligUnit(sampling_unit_id, attribute, value) changes the attribute (e.g. latitude or longitude) of the sampling unit to the specified value. The operation insertData(observation record, site, protocol, sampling unit, timestamps, data collectors) saves a new observation record into the database and associates it with specified objects. The operation updateData(protocol, data_id, attribute, value) modifies the attribute of an existing observation record to the specified value. All the insert or update operations require: 1) authorization to ensure the user has necessary privileges to perform the operation; 2) timestamp validation to ensure the observation timestamps are in the designated time range specified in the sampling schedule; 3) data validation to check that the data records use correct taxonomy terms and data values. No authorization is performed for get operations, but under some specific condition, a username may be required for the purpose of authentication. Along with the validations above, the TEAM data model also supports human based data validation on observed data through the Data Review subsystem to ensure data quality. The data review is implemented by adding two attributes review_tag and review_comment to each observation data record. The attribute review_tag is used by a reviewer to specify the quality of data, and the attribute review_comment is for reviewers to give more information when a problem is identified. The review_tag attribute can be populated by either the system conducting QA/QC tests or by pre-specified scientific experts. The following is the review operation, which is actually a special case of the operation updateData: The operation updateReview(protocol, data_id, judgment, comment) sets the attribute review_tag and review_comment to the specified values. By systematically tracking every step, The TEAM data model can roll back to any previous state. This is achieved by introducing a historical data container for each editable object type. When the operation updateData is applied to an object to modify its attribute, the object will be tagged with the current timestamp and the name of the user who conducts the operation, the tagged object will then be moved into the historical data container, and finally a new object will be created with the new value for the specified attribute. The diagram illustrates the architecture of the TEAM data management system. A data collector can use the Data Ingestion subsystem to load new data records into the TEAM data model. The system establishes a first level of review (i.e. meets minimum data standards via QA/QC tests). Further review is done via experts and they can verify and provide their comments on data records through the Data Review subsystem. The data editor can then address data records based on the reviewer's comments. Users can use the Data Query and Download application to find data by sites, protocols and time ranges. The Data Query and Download system packages selected data with the data license and important metadata information into a single package and delivers it to the user.

  1. LTR real-time PCR for HIV-1 DNA quantitation in blood cells for early diagnosis in infants born to seropositive mothers treated in HAART area (ANRS CO 01).

    PubMed

    Avettand-Fènoël, Véronique; Chaix, Marie-Laure; Blanche, Stéphane; Burgard, Marianne; Floch, Corinne; Toure, Kadidia; Allemon, Marie-Christine; Warszawski, Josiane; Rouzioux, Christine

    2009-02-01

    HIV-1 diagnosis in babies born to seropositive mothers is one of the challenges of HIV epidemics in children. A simple, rapid protocol was developed for quantifying HIV-1 DNA in whole blood samples and was used in the ANRS French pediatric cohort in conditions of prevention of mother-to-child transmission. A quantitative HIV-1 DNA protocol (LTR real-time PCR) requiring small blood volumes was developed. First, analytical reproducibility was evaluated on 172 samples. Results obtained on blood cell pellets and Ficoll-Hypaque separated mononuclear cells were compared in 48 adult HIV-1 samples. Second, the protocol was applied to HIV-1 diagnosis in infants in parallel with plasma HIV-RNA quantitation. This prospective study was performed in children born between May 2005 and April 2007 included in the ANRS cohort. The assay showed good reproducibility. The 95% detection cut-off value was 6 copies/PCR, that is, 40 copies/10(6) leukocytes. HIV-DNA levels in whole blood were highly correlated with those obtained after Ficoll-Hypaque separation (r = 0.900, P < 0.0001). A total of 3,002 specimens from 1,135 infants were tested. The specificity of HIV-DNA and HIV-RNA assays was 100%. HIV-1 infection was diagnosed in nine infants before age 60 days. HIV-DNA levels were low, underlining the need for sensitive assays when highly active antiretroviral therapy (HAART) has been given. The performances of this HIV-DNA assay showed that it is adapted to early diagnosis in children. The results were equivalent to those of HIV-RNA assay. HIV-DNA may be used even in masked primary infection in newborns whose mothers have received HAART. (c) 2008 Wiley-Liss, Inc.

  2. CE microchips: an opened gate to food analysis.

    PubMed

    Escarpa, Alberto; González, María Cristina; Crevillén, Agustín González; Blasco, Antonio Javier

    2007-03-01

    CE microchips are the first generation of micrototal analysis systems (-TAS) emerging in the miniaturization scene of food analysis. CE microchips for food analysis are fabricated in both glass and polymer materials, such as PDMS and poly(methyl methacrylate) (PMMA), and use simple layouts of simple and double T crosses. Nowadays, the detection route preferred is electrochemical in both, amperometry and conductivity modes, using end-channel and contactless configurations, respectively. Food applications using CE microchips are now emerging since food samples present complex matrices, the selectivity being a very important challenge because the total integration of analytical steps into microchip format is very difficult. As a consequence, the first contributions that have recently appeared in the relevant literature are based primarily on fast separations of analytes of high food significance. These protocols are combined with different strategies to achieve selectivity using a suitable nonextensive sample preparation and/or strategically choosing detection routes. Polyphenolic compounds, amino acids, preservatives, and organic and inorganic ions have been studied using CE microchips. Thus, new and exciting future expectations arise in the domain of food analysis. However, several drawbacks could easily be found and assumed within the miniaturization map.

  3. Derivatization coupled to headspace programmed-temperature vaporizer gas chromatography with mass spectrometry for the determination of amino acids: Application to urine samples.

    PubMed

    González Paredes, Rosa María; García Pinto, Carmelo; Pérez Pavón, José Luis; Moreno Cordero, Bernardo

    2016-09-01

    A new method based on headspace programmed-temperature vaporizer gas chromatography with mass spectrometry has been developed and validated for the determination of amino acids (alanine, sarcosine, ethylglycine, valine, leucine, and proline) in human urine samples. Derivatization with ethyl chloroformate was employed successfully to determine the amino acids. The derivatization reaction conditions as well as the variables of the headspace sampling were optimized. The existence of a matrix effect was checked and the analytical characteristics of the method were determined. The limits of detection were 0.15-2.89 mg/L, and the limits of quantification were 0.46-8.67 mg/L. The instrumental repeatability was 1.6-11.5%. The quantification of the amino acids in six urine samples from healthy subjects was performed with the method developed with the one-point standard additions protocol, with norleucine as the internal standard. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Conventional and Accelerated-Solvent Extractions of Green Tea (Camellia sinensis) for Metabolomics-based Chemometrics

    PubMed Central

    Kellogg, Joshua J.; Wallace, Emily D.; Graf, Tyler N.; Oberlies, Nicholas H.; Cech, Nadja B.

    2018-01-01

    Metabolomics has emerged as an important analytical technique for multiple applications. The value of information obtained from metabolomics analysis depends on the degree to which the entire metabolome is present and the reliability of sample treatment to ensure reproducibility across the study. The purpose of this study was to compare methods of preparing complex botanical extract samples prior to metabolomics profiling. Two extraction methodologies, accelerated solvent extraction and a conventional solvent maceration, were compared using commercial green tea [Camellia sinensis (L.) Kuntze (Theaceae)] products as a test case. The accelerated solvent protocol was first evaluated to ascertain critical factors influencing extraction using a D-optimal experimental design study. The accelerated solvent and conventional extraction methods yielded similar metabolite profiles for the green tea samples studied. The accelerated solvent extraction yielded higher total amounts of extracted catechins, was more reproducible, and required less active bench time to prepare the samples. This study demonstrates the effectiveness of accelerated solvent as an efficient methodology for metabolomics studies. PMID:28787673

  5. On Equivalence between Critical Probabilities of Dynamic Gossip Protocol and Static Site Percolation

    NASA Astrophysics Data System (ADS)

    Ishikawa, Tetsuya; Hayakawa, Tomohisa

    The relationship between the critical probability of gossip protocol on the square lattice and the critical probability of site percolation on the square lattice is discussed. Specifically, these two critical probabilities are analytically shown to be equal to each other. Furthermore, we present a way of evaluating the critical probability of site percolation by approximating the saturation of gossip protocol. Finally, we provide numerical results which support the theoretical analysis.

  6. Optimisation d'analyses de grenat almandin realisees au microscope electronique a balayage

    NASA Astrophysics Data System (ADS)

    Larose, Miguel

    The electron microprobe (EMP) is considered as the golden standard for the collection of precise and representative chemical composition of minerals in rocks, but data of similar quality should be obtainable with a scanning electron microscope (SEM). This thesis presents an analytical protocol aimed at optimizing operational parameters of an SEM paired with an EDS Si(Li) X-ray detector (JEOL JSM-840A) for the imaging, quantitative chemical analysis and compositional X-ray maps of almandine garnet found in pelitic schists from the Canadian Cordillera. Results are then compared to those obtained for the same samples on a JEOL JXA 8900 EMP. For imaging purposes, the secondary electrons and backscattered electrons signals have been used to obtain topographic and chemical contrast of the samples, respectively. The SEM allows the acquisition of images with higher resolution than the EMP when working at high magnifications. However, for millimetric size minerals requiring very low magnifications, the EMP can usually match the imaging capabilities of an SEM. When optimizing images for both signals, the optimal operational parameters to show similar contrasts are not restricted to a unique combination of values. Optimization of operational parameters for quantitative chemical analysis resulted in analytical data with a similar precision and showing good correlation to that obtained with an EMP. Optimization of operational parameters for compositional X-ray maps aimed at maximizing the collected intensity within a pixel as well as complying with the spatial resolution criterion in order to obtain a qualitative compositional map representative of the chemical variation within the grain. Even though various corrections were needed, such as the shadow effect and the background noise removal, as well as the impossibility to meet the spatial resolution criterion because of the limited pixel density available on the SEM, the compositional X-ray maps show a good correlation with those obtained with the EMP, even for concentrations as low as 0,5%. When paired with a rigorous analytical protocol, the use of an SEM equipped with an EDS Si (Li) X-ray detector allows the collection of qualitative and quantitative results similar to those obtained with an EMP for all three of the applications considered.

  7. Evaluation of the performance of Human Papillomavirus testing in paired urine and clinician-collected cervical samples among women aged over 30 years in Bhutan.

    PubMed

    Tshomo, Ugyen; Franceschi, Silvia; Tshokey, Tshokey; Tobgay, Tashi; Baussano, Iacopo; Tenet, Vanessa; Snijders, Peter J F; Gheit, Tarik; Tommasino, Massimo; Vorsters, Alex; Clifford, Gary M

    2017-04-08

    Urine sampling may offer a less invasive solution than cervical sampling to test for human papillomavirus (HPV) for HPV vaccine impact monitoring. Paired samples of urine and exfoliated cervical cells were obtained for 89 women with history of high-risk (HR) HPV-positive normal cytology in Bhutan. Urine sampling protocol included self-collection of first-void urine immediately into a conservation medium and procedures to optimize DNA yield. Colposcopical abnormalities were biopsied. Two HPV assays were used: a multiplex type-specific PCR (E7-MPG) and a less analytically sensitive GP5+/6+ PCR followed by reverse line blot. HPV positivity for 21 types common to both assays was similar in urine and cells by E7-MPG (62.9% and 57.3%, respectively, p = 0.32) but lower in urine by GP5+/6+ (30.3% and 40.4%, p = 0.05). HPV6/11/16/18 positivity did not significantly differ between urine and cells by either assay. Sensitivity of urine (using cells as gold standard) to detect 21 HPV types was 80% and 58% for E7-MPG and GP5+/6+, respectively, with specificity 61% and 89%. HPV type distribution in urine and cells was similar, regardless of assay. The 5 detected CIN3+ were HR-HPV positive in cells by both assays, compared to 4 and 3 by E7-MPG and GP5+/6+, respectively, in urine samples. For the monitoring of vaccine impact, we demonstrate validity of a urine sampling protocol to obtain HPV prevalence data that are broadly comparable to that from cervical cells. However, detection of HPV in urine varies according to assay sensitivity, presumably because low level infections are frequent.

  8. Multi-class multi-residue analysis of veterinary drugs in meat using enhanced matrix removal lipid cleanup and liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhao, Limian; Lucas, Derick; Long, David; Richter, Bruce; Stevens, Joan

    2018-05-11

    This study presents the development and validation of a quantitation method for the analysis of multi-class, multi-residue veterinary drugs using lipid removal cleanup cartridges, enhanced matrix removal lipid (EMR-Lipid), for different meat matrices by liquid chromatography tandem mass spectrometry detection. Meat samples were extracted using a two-step solid-liquid extraction followed by pass-through sample cleanup. The method was optimized based on the buffer and solvent composition, solvent additive additions, and EMR-Lipid cartridge cleanup. The developed method was then validated in five meat matrices, porcine muscle, bovine muscle, bovine liver, bovine kidney and chicken liver to evaluate the method performance characteristics, such as absolute recoveries and precision at three spiking levels, calibration curve linearity, limit of quantitation (LOQ) and matrix effect. The results showed that >90% of veterinary drug analytes achieved satisfactory recovery results of 60-120%. Over 97% analytes achieved excellent reproducibility results (relative standard deviation (RSD) < 20%), and the LOQs were 1-5 μg/kg in the evaluated meat matrices. The matrix co-extractive removal efficiency by weight provided by EMR-lipid cartridge cleanup was 42-58% in samples. The post column infusion study showed that the matrix ion suppression was reduced for samples with the EMR-Lipid cartridge cleanup. The reduced matrix ion suppression effect was also confirmed with <15% frequency of compounds with significant quantitative ion suppression (>30%) for all tested veterinary drugs in all of meat matrices. The results showed that the two-step solid-liquid extraction provides efficient extraction for the entire spectrum of veterinary drugs, including the difficult classes such as tetracyclines, beta-lactams etc. EMR-Lipid cartridges after extraction provided efficient sample cleanup with easy streamlined protocol and minimal impacts on analytes recovery, improving method reliability and consistency. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Sampling for pharmaceuticals and personal care products (PPCPs) and illicit drugs in wastewater systems: are your conclusions valid? A critical review.

    PubMed

    Ort, Christoph; Lawrence, Michael G; Rieckermann, Jörg; Joss, Adriano

    2010-08-15

    The analysis of 87 peer-reviewed journal articles reveals that sampling for pharmaceuticals and personal care products (PPCPs) and illicit drugs in sewers and sewage treatment plant influents is mostly carried out according to existing tradition or standard laboratory protocols. Less than 5% of all studies explicitly consider internationally acknowledged guidelines or methods for the experimental design of monitoring campaigns. In the absence of a proper analysis of the system under investigation, the importance of short-term pollutant variations was typically not addressed. Therefore, due to relatively long sampling intervals, potentially inadequate sampling modes, or insufficient documentation, it remains unclear for the majority of reviewed studies whether observed variations can be attributed to "real" variations or if they simply reflect sampling artifacts. Based on results from previous and current work, the present paper demonstrates that sampling errors can lead to overinterpretation of measured data and ultimately, wrong conclusions. Depending on catchment size, sewer type, sampling setup, substance of interest, and accuracy of analytical method, avoidable sampling artifacts can range from "not significant" to "100% or more" for different compounds even within the same study. However, in most situations sampling errors can be reduced greatly, and sampling biases can be eliminated completely, by choosing an appropriate sampling mode and frequency. This is crucial, because proper sampling will help to maximize the value of measured data for the experimental assessment of the fate of PPCPs as well as for the formulation and validation of mathematical models. The trend from reporting presence or absence of a compound in "clean" water samples toward the quantification of PPCPs in raw wastewater requires not only sophisticated analytical methods but also adapted sampling methods. With increasing accuracy of chemical analyses, inappropriate sampling increasingly represents the major source of inaccuracy. A condensed step-by-step Sampling Guide is proposed as a starting point for future studies.

  10. Concurrent measurement of cellular turbidity and hemoglobin to evaluate the antioxidant activity of plants.

    PubMed

    Bellik, Yuva; Iguer-Ouada, Mokrane

    2016-01-01

    In past decades, a multitude of analytical methods for measuring antioxidant activity of plant extracts has been developed. However, when using methods to determine hemoglobin released from human erythrocytes treated with ginger extracts, we found hemoglobin concentrations were significantly higher than in untreated control samples. This suggests in the presence of antioxidants that measuring hemoglobin alone is not sufficient to determine hemolysis. We show concurrent measurement of erythrocyte concentration and hemoglobin is essential in such assays, and describe a new protocol based on simultaneous measurement of cellular turbidity and hemoglobin. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Exposure assessment for endocrine disruptors: some considerations in the design of studies.

    PubMed Central

    Rice, Carol; Birnbaum, Linda S; Cogliano, James; Mahaffey, Kathryn; Needham, Larry; Rogan, Walter J; vom Saal, Frederick S

    2003-01-01

    In studies designed to evaluate exposure-response relationships in children's development from conception through puberty, multiple factors that affect the generation of meaningful exposure metrics must be considered. These factors include multiple routes of exposure; the timing, frequency, and duration of exposure; need for qualitative and quantitative data; sample collection and storage protocols; and the selection and documentation of analytic methods. The methods for exposure data collection and analysis must be sufficiently robust to accommodate the a priori hypotheses to be tested, as well as hypotheses generated from the data. A number of issues that must be considered in study design are summarized here. PMID:14527851

  12. White HDPE bottles as source of serious contamination of water samples with Ba and Zn.

    PubMed

    Reimann, Clemens; Grimstvedt, Andreas; Frengstad, Bjørn; Finne, Tor Erik

    2007-03-15

    During a recent study of surface water quality factory new white high-density polyethylene (HDPE) bottles were used for collecting the water samples. According to the established field protocol of the Geological Survey of Norway the bottles were twice carefully rinsed with water in the field prior to sampling. Several blank samples using milli-Q (ELGA) water (>18.2 MOmega) were also prepared. On checking the analytical results the blanks returned values of Ag, Ba, Sr, V, Zn and Zr. For Ba and Zn the values (c. 300 microg/l and 95 microg/l) were about 10 times above the concentrations that can be expected in natural waters. A laboratory test of the bottles demonstrated that the bottles contaminate the samples with significant amounts of Ba and Zn and some Sr. Simple acid washing of the bottles prior to use did not solve the contamination problem for Ba and Zn. The results suggest that there may exist "clean" and "dirty" HDPE bottles depending on manufacturer/production process. When collecting water samples it is mandatory to check bottles regularly as a possible source of contamination.

  13. Quantitation of heat-shock proteins in clinical samples using mass spectrometry.

    PubMed

    Kaur, Punit; Asea, Alexzander

    2011-01-01

    Mass spectrometry (MS) is a powerful analytical tool for proteomics research and drug and biomarker discovery. MS enables identification and quantification of known and unknown compounds by revealing their structural and chemical properties. Proper sample preparation for MS-based analysis is a critical step in the proteomics workflow because the quality and reproducibility of sample extraction and preparation for downstream analysis significantly impact the separation and identification capabilities of mass spectrometers. The highly expressed proteins represent potential biomarkers that could aid in diagnosis, therapy, or drug development. Because the proteome is so complex, there is no one standard method for preparing protein samples for MS analysis. Protocols differ depending on the type of sample, source, experiment, and method of analysis. Molecular chaperones play significant roles in almost all biological functions due to their capacity for detecting intracellular denatured/unfolded proteins, initiating refolding or denaturation of such malfolded protein sequences and more recently for their role in the extracellular milieu as chaperokines. In this chapter, we describe the latest techniques for quantitating the expression of molecular chaperones in human clinical samples.

  14. Keeping It Simple: Can We Estimate Malting Quality Potential Using an Isothermal Mashing Protocol and Common Laboratory Instrumentation?

    USDA-ARS?s Scientific Manuscript database

    Current methods for generating malting quality metrics have been developed largely to support commercial malting and brewing operations, providing accurate, reproducible analytical data to guide malting and brewing production. Infrastructure to support these analytical operations often involves sub...

  15. Student Career Decisions: The Limits of Rationality.

    ERIC Educational Resources Information Center

    Baumgardner, Steve R.; Rappoport, Leon

    This study compares modes of cognitive functioning revealed in student selection of a college major. Students were interviewed in-depth concerning reasons for their choice of majors. Protocol data suggested two distinct modes of thinking were evident on an analytic-intuitive dimension. For operational purposes analytic thinking was defined by…

  16. An Energy-Dispersive X-Ray Fluorescence Spectrometry and Monte Carlo simulation study of Iron-Age Nuragic small bronzes ("Navicelle") from Sardinia, Italy

    NASA Astrophysics Data System (ADS)

    Schiavon, Nick; de Palmas, Anna; Bulla, Claudio; Piga, Giampaolo; Brunetti, Antonio

    2016-09-01

    A spectrometric protocol combining Energy Dispersive X-Ray Fluorescence Spectrometry with Monte Carlo simulations of experimental spectra using the XRMC code package has been applied for the first time to characterize the elemental composition of a series of famous Iron Age small scale archaeological bronze replicas of ships (known as the ;Navicelle;) from the Nuragic civilization in Sardinia, Italy. The proposed protocol is a useful, nondestructive and fast analytical tool for Cultural Heritage sample. In Monte Carlo simulations, each sample was modeled as a multilayered object composed by two or three layers depending on the sample: when all present, the three layers are the original bronze substrate, the surface corrosion patina and an outermost protective layer (Paraloid) applied during past restorations. Monte Carlo simulations were able to account for the presence of the patina/corrosion layer as well as the presence of the Paraloid protective layer. It also accounted for the roughness effect commonly found at the surface of corroded metal archaeological artifacts. In this respect, the Monte Carlo simulation approach adopted here was, to the best of our knowledge, unique and enabled to determine the bronze alloy composition together with the thickness of the surface layers without the need for previously removing the surface patinas, a process potentially threatening preservation of precious archaeological/artistic artifacts for future generations.

  17. Technology-assisted psychoanalysis.

    PubMed

    Scharff, Jill Savege

    2013-06-01

    Teleanalysis-remote psychoanalysis by telephone, voice over internet protocol (VoIP), or videoteleconference (VTC)-has been thought of as a distortion of the frame that cannot support authentic analytic process. Yet it can augment continuity, permit optimum frequency of analytic sessions for in-depth analytic work, and enable outreach to analysands in areas far from specialized psychoanalytic centers. Theoretical arguments against teleanalysis are presented and countered and its advantages and disadvantages discussed. Vignettes of analytic process from teleanalytic sessions are presented, and indications, contraindications, and ethical concerns are addressed. The aim is to provide material from which to judge the authenticity of analytic process supported by technology.

  18. Standardization and validation of real time PCR assays for the diagnosis of histoplasmosis using three molecular targets in an animal model

    PubMed Central

    López, Luisa F.; Muñoz, César O.; Cáceres, Diego H.; Tobón, Ángela M.; Loparev, Vladimir; Clay, Oliver; Chiller, Tom; Litvintseva, Anastasia; Gade, Lalitha; González, Ángel

    2017-01-01

    Histoplasmosis is considered one of the most important endemic and systemic mycoses worldwide. Until now few molecular techniques have been developed for its diagnosis. The aim of this study was to develop and evaluate three real time PCR (qPCR) protocols for different protein-coding genes (100-kDa, H and M antigens) using an animal model. Fresh and formalin-fixed and paraffin-embedded (FFPE) lung tissues from BALB/c mice inoculated i.n. with 2.5x106 Histoplasma capsulatum yeast or PBS were obtained at 1, 2, 3, 4, 8, 12 and 16 weeks post-infection. A collection of DNA from cultures representing different clades of H. capsulatum (30 strains) and other medically relevant pathogens (36 strains of related fungi and Mycobacterium tuberculosis) were used to analyze sensitivity and specificity. Analytical sensitivity and specificity were 100% when DNAs from the different strains were tested. The highest fungal burden occurred at first week post-infection and complete fungal clearance was observed after the third week; similar results were obtained when the presence of H. capsulatum yeast cells was demonstrated in histopathological analysis. In the first week post-infection, all fresh and FFPE lung tissues from H. capsulatum-infected animals were positive for the qPCR protocols tested except for the M antigen protocol, which gave variable results when fresh lung tissue samples were analyzed. In the second week, all qPCR protocols showed variable results for both fresh and FFPE tissues. Samples from the infected mice at the remaining times post-infection and uninfected mice (controls) were negative for all protocols. Good agreement was observed between CFUs, histopathological analysis and qPCR results for the 100-kDa and H antigen protocols. We successfully standardized and validated three qPCR assays for detecting H. capsulatum DNA in fresh and FFPE tissues, and conclude that the 100-kDa and H antigen molecular assays are promising tests for diagnosing this mycosis. PMID:29287097

  19. The identification and characterization of non-coding and coding RNAs and their modified nucleosides by mass spectrometry

    PubMed Central

    Gaston, Kirk W; Limbach, Patrick A

    2014-01-01

    The analysis of ribonucleic acids (RNA) by mass spectrometry has been a valuable analytical approach for more than 25 years. In fact, mass spectrometry has become a method of choice for the analysis of modified nucleosides from RNA isolated out of biological samples. This review summarizes recent progress that has been made in both nucleoside and oligonucleotide mass spectral analysis. Applications of mass spectrometry in the identification, characterization and quantification of modified nucleosides are discussed. At the oligonucleotide level, advances in modern mass spectrometry approaches combined with the standard RNA modification mapping protocol enable the characterization of RNAs of varying lengths ranging from low molecular weight short interfering RNAs (siRNAs) to the extremely large 23 S rRNAs. New variations and improvements to this protocol are reviewed, including top-down strategies, as these developments now enable qualitative and quantitative measurements of RNA modification patterns in a variety of biological systems. PMID:25616408

  20. The identification and characterization of non-coding and coding RNAs and their modified nucleosides by mass spectrometry.

    PubMed

    Gaston, Kirk W; Limbach, Patrick A

    2014-01-01

    The analysis of ribonucleic acids (RNA) by mass spectrometry has been a valuable analytical approach for more than 25 years. In fact, mass spectrometry has become a method of choice for the analysis of modified nucleosides from RNA isolated out of biological samples. This review summarizes recent progress that has been made in both nucleoside and oligonucleotide mass spectral analysis. Applications of mass spectrometry in the identification, characterization and quantification of modified nucleosides are discussed. At the oligonucleotide level, advances in modern mass spectrometry approaches combined with the standard RNA modification mapping protocol enable the characterization of RNAs of varying lengths ranging from low molecular weight short interfering RNAs (siRNAs) to the extremely large 23 S rRNAs. New variations and improvements to this protocol are reviewed, including top-down strategies, as these developments now enable qualitative and quantitative measurements of RNA modification patterns in a variety of biological systems.

  1. RESPONSE PROTOCOL TOOLBOX: PLANNING FOR AND RESPONDING TO DRINKING WATER CONTAMINATION THREATS AND INCIDENTS. MODULE 4: ANALYTICAL GUIDE. INTERIM FINAL - DECEMBER 2003

    EPA Science Inventory

    The interim final Response Protocol Toolbox: Planning for and Responding to Contamination Threats to Drinking Water Systems is designed to help the water sector effectively and appropriately respond to intentional contamination threats and incidents. It was produced by EPA, buil...

  2. Development and Preliminary Evaluation of a FAP Protocol: Brief Relationship Enhancement

    ERIC Educational Resources Information Center

    Holman, Gareth; Kohlenberg, Robert J.; Tsai, Mavis

    2012-01-01

    The purpose of this study was to develop a brief Functional Analytic Psychotherapy (FAP) protocol that will facilitate reliable implementation of FAP interventions, thus supporting research on FAP process and outcome. The treatment was a four-session individual therapy for clients who were interested in improving their relationship with their…

  3. Development of a NIST standard reference material containing thirty volatile organic compounds at 5 nmol/mol in nitrogen.

    PubMed

    Rhoderick, George C; Yen, James H

    2006-05-01

    Primary gravimetric gas cylinder standards containing 30 volatile organic compounds (VOCs) in nitrogen were prepared using a procedure previously developed to prepare gas mixture cylinder standards of VOCs at the 5 nmol/mol level. This set of primary standards was intercompared to existing gas cylinder standards, containing as many as 19 of the 30 volatile organics present in these new primaries, using gas chromatography with a hydrogen flame ionization detector coupled with cryogenic preconcentration. The linear regression analysis showed excellent agreement among the standards for each compound. Similar mixtures containing many of these compounds in treated aluminum gas cylinders have been evaluated over time and have shown stability for as much as 10 years. The development of these 30-component primary standards led to the preparation and certification of a reissue of Standard Reference Material (SRM) 1804 at the nominal amount-of-substance fraction of 5 nmol/mol for each analyte. A lot of 20 cylinders containing the mixture was prepared at NIST following previously demonstrated protocols for preparation of the cylinders. Each cylinder was analyzed against one cylinder from the lot, designated as the "lot standard," for each of the 30 compounds. As a result of the uncertainty analysis, the data showed that rather than declaring the lot homogeneous with a much higher uncertainty, each cylinder could be individually certified. The expanded uncertainty limits ranged from 1.5 to 10% for 28 of the 30 analytes, with two of the analytes having uncertainties as high as 19% in those SRM cylinders certified. Due to stability issues and some high uncertainties for a few analytes in 2 of the samples, 18 of the 20 candidate SRM samples were certified. These volatile organic gas mixtures represent the most complex gas SRMs developed at NIST.

  4. Development of an analytical method for the simultaneous analysis of MCPD esters and glycidyl esters in oil-based foodstuffs.

    PubMed

    Ermacora, Alessia; Hrnčiřík, Karel

    2014-01-01

    Substantial progress has been recently made in the development and optimisation of analytical methods for the quantification of 2-MCPD, 3-MCPD and glycidyl esters in oils and fats, and there are a few methods currently available that allow a reliable quantification of these contaminants in bulk oils and fats. On the other hand, no standard method for the analysis of foodstuffs has yet been established. The aim of this study was the development and validation of a new method for the simultaneous quantification of 2-MCPD, 3-MCPD and glycidyl esters in oil-based food products. The developed protocol includes a first step of liquid-liquid extraction and purification of the lipophilic substances of the sample, followed by the application of a previously developed procedure based on acid transesterification, for the indirect quantification of these contaminants in oils and fats. The method validation was carried out on food products (fat-based spreads, creams, margarine, mayonnaise) manufactured in-house, in order to control the manufacturing process and account for any food matrix-analyte interactions (the sample spiking was carried out on the single components used for the formulations rather than the final products). The method showed good accuracy (the recoveries ranged from 97% to 106% for bound 3-MCPD and 2-MCPD and from 88% to 115% for bound glycidol) and sensitivity (the LOD was 0.04 and 0.05 mg kg(-1) for bound MCPD and glycidol, respectively). Repeatability and reproducibility were satisfactory (RSD below 2% and 5%, respectively) for all analytes. The levels of salts and surface-active compounds in the formulation were found to have no impact on the accuracy and the other parameters of the method.

  5. Theoretical and experimental analysis of analyte transport in a fiber-optic, protein C immuno-biosensor.

    PubMed

    Tang, Liang; Kwon, Hyun J; Kang, Kyung A

    2004-12-30

    Protein C (PC) is an important anticoagulant in human blood plasma, and early diagnosis of PC deficiency is critical for preventing dangerous thromboembolic complications. A fiber-optic PC immuno-biosensor has been under development in our research group for real-time PC-deficiency diagnosis. The sensor has demonstrated a good sensitivity and specificity for quantifying PC in buffered solutions. However, for plasma samples, with a limited sample reaction time, the sensor produced only 30% of the signal intensity of PC in buffer. The high plasma viscosity (1.9 cP) was speculated as the major reason for signal intensity reduction. In this investigation, the sensing performance of the fiber-optic PC biosensor is systematically characterized in terms of physical and chemical properties of the sample media. Theoretical and experimental analyses indicate that the reduced diffusion rate of PC molecules in viscous samples caused the sensing system to be more mass-transfer-limited. Convective flow of sample/reagent solutions during immunoreactions can increase the rate of the analyte mass transport from the bulk solution to the sensor surface, with reaction kinetics changing from mass-transfer-limited to reaction-limited as flow velocity increases. It was shown that PC sensor performance was significantly improved for plasma samples with convection. The effect of the flow velocity and incubation times for samples and reagents on the sensor performance was also systematically analyzed to optimize the assay protocol for PC sensing. Currently, a 6-cm-long immuno-biosensor is capable of quantifying PC in plasma (1 mL) in the heterozygous PC deficiency range (0.5 to 2.5 microg/mL) within 5 minutes, at an average signal-to-noise ratio of 50. 2004 Wiley Periodicals, Inc.

  6. Method development for compositional analysis of low molecular weight poly(vinyl acetate) by matrix-assisted/laser desorption-mass spectrometry and its application to analysis of chewing gum.

    PubMed

    Tisdale, Evgenia; Wilkins, Charles

    2014-04-11

    The influence of the sample preparation parameters (the choice of the solvent and of the matrix:analyte ratio) was investigated and optimal conditions were established for MALDI mass spectrometry analysis of the pristine low molecular weight polyvinyl acetate (PVAc). It was demonstrated that comparison of polymer's and solvent's Hansen solubility parameters could be used as a guide when choosing the solvent for MALDI sample preparation. The highest intensity PVAc signals were obtained when ethyl acetate was used as a solvent along with the lowest matrix-analyte ratio (2,5-dihydroxybenzoic acid was used as a matrix in all experiments). The structure of the PVAc was established with high accuracy using the matrix-assisted laser desorption/ionization-Fourier transform mass spectrometry (MALDI-FTMS) analysis. It was demonstrated that PVAc undergoes unimolecular decomposition by losing acetic acid molecules from its backbone under the conditions of FTMS measurements. Number and weight average molecular weights as well as polydispersity indices were determined with both MALDI-TOF and MALDI-FTMS methods. The sample preparation protocol developed was applied to the analysis of a chewing gum and the molecular weight and structure of the polyvinyl acetate present in the sample were established. Thus, it was shown that optimized MALDI mass spectrometry could be used successfully for characterization of polyvinyl acetate in commercially available chewing gum. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Nano carbon black-based screen printed sensor for carbofuran, isoprocarb, carbaryl and fenobucarb detection: application to grain samples.

    PubMed

    Della Pelle, Flavio; Angelini, Claudia; Sergi, Manuel; Del Carlo, Michele; Pepe, Alessia; Compagnone, Dario

    2018-08-15

    An electrochemical screening assay for the detection of phenyl carbamates (i.e. carbaryl, carbofuran, isoprocarb and fenobucarb) was developed and applied to grains samples (i.e. durum wheat, soft wheat and maize). Nano carbon black (CB) was strategically employed to realize an effective, reproducible, fouling resistant, low cost, delocalisable screen printed sensor (CB-SPE). CB-SPEs morphology (SEM and FEM) and electrochemical property (CV and EIS) were studied. The final pesticides analysis protocol consist of: (i) extraction of the analyte (just by mixing), (ii) alkaline hydrolysis (10 min R.T.), (iii) DPV detection directly of 100 µL of extract on the CB-SPE surface. Linear range between 1.0 × 10 -7 and 1.0 × 10 -4 mol L -1 , good determination coefficients (R 2 ≥ 0.9971) and satisfactory sensitivity (≥ 3.90 × 10 -1 A M -1 cm -2 ) and LODs (≤ 8.0 × 10 -8 mol L -1 ) were obtained for all the analytes. Excellent recoveries (78-102%) and accuracy (relative error vs. HPLC-MS/MS between 9.0% and -7.8%) resulted from the analysis of grains samples. The proposed CB-SPE based approach has demonstrated to be able to detect carbaryl at Maximum residue limits levels (MRLs), allowing class selective detection of commonly employed phenyl carbamates in food samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Second-order data obtained by beta-cyclodextrin complexes: a novel approach for multicomponent analysis with three-way multivariate calibration methods.

    PubMed

    Khani, Rouhollah; Ghasemi, Jahan B; Shemirani, Farzaneh

    2014-10-01

    This research reports the first application of β-cyclodextrin (β-CD) complexes as a new method for generation of three way data, combined with second-order calibration methods for quantification of a binary mixture of caffeic (CA) and vanillic (VA) acids, as model compounds in fruit juices samples. At first, the basic experimental parameters affecting the formation of inclusion complexes between target analytes and β-CD were investigated and optimized. Then under the optimum conditions, parallel factor analysis (PARAFAC) and bilinear least squares/residual bilinearization (BLLS/RBL) were applied for deconvolution of trilinear data to get spectral and concentration profiles of CA and VA as a function of β-CD concentrations. Due to severe concentration profile overlapping between CA and VA in β-CD concentration dimension, PARAFAC could not be successfully applied to the studied samples. So, BLLS/RBL performed better than PARAFAC. The resolution of the model compounds was possible due to differences in the spectral absorbance changes of the β-CD complexes signals of the investigated analytes, opening a new approach for second-order data generation. The proposed method was validated by comparison with a reference method based on high-performance liquid chromatography photodiode array detection (HPLC-PDA), and no significant differences were found between the reference values and the ones obtained with the proposed method. Such a chemometrics-based protocol may be a very promising tool for more analytical applications in real samples monitoring, due to its advantages of simplicity, rapidity, accuracy, sufficient spectral resolution and concentration prediction even in the presence of unknown interferents. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Tracking emerging mycotoxins in food: development of an LC-MS/MS method for free and modified Alternaria toxins.

    PubMed

    Puntscher, Hannes; Kütt, Mary-Liis; Skrinjar, Philipp; Mikula, Hannes; Podlech, Joachim; Fröhlich, Johannes; Marko, Doris; Warth, Benedikt

    2018-05-16

    Mycotoxins produced by Alternaria fungi are ubiquitous food contaminants, but analytical methods for generating comprehensive exposure data are rare. We describe the development of an LC-MS/MS method covering 17 toxins for investigating the natural occurrence of free and modified Alternaria toxins in tomato sauce, sunflower seed oil, and wheat flour. Target analytes included alternariol (AOH), AOH-3-glucoside, AOH-9-glucoside, AOH-3-sulfate, alternariol monomethyl ether (AME), AME-3-glucoside, AME-3-sulfate, altenuene, isoaltenuene, tenuazonic acid (TeA), tentoxin (TEN), altertoxin I and II, alterperylenol, stemphyltoxin III, altenusin, and altenuic acid III. Extensive optimization resulted in a time- and cost-effective sample preparation protocol and a chromatographic baseline separation of included isomers. Overall, adequate limits of detection (0.03-9 ng/g) and quantitation (0.6-18 ng/g), intermediate precision (9-44%), and relative recovery values (75-100%) were achieved. However, stemphyltoxin III, AOH-3-sulfate, AME-3-sulfate, altenusin, and altenuic acid III showed recoveries in wheat flour below 70%, while their performance was stable and reproducible. Our pilot study with samples from the Austrian retail market demonstrated that tomato sauces (n = 12) contained AOH, AME, TeA, and TEN in concentrations up to 20, 4, 322, and 0.6 ng/g, while sunflower seed oil (n = 7) and wheat flour samples (n = 9) were contaminated at comparatively lower levels. Interestingly and of relevance for risk assessment, AOH-9-glucoside, discovered for the first time in naturally contaminated food items, and AME-3-sulfate were found in concentrations similar to their parent toxins. In conclusion, the established multi-analyte method proved to be fit for purpose for generating comprehensive Alternaria toxin occurrence data in different food matrices. Graphical abstract ᅟ.

  10. Inter-comparison of NIOSH and IMPROVE protocols for OC and EC determination: implications for inter-protocol data conversion

    NASA Astrophysics Data System (ADS)

    Wu, Cheng; Huang, X. H. Hilda; Ng, Wai Man; Griffith, Stephen M.; Zhen Yu, Jian

    2016-09-01

    Organic carbon (OC) and elemental carbon (EC) are operationally defined by analytical methods. As a result, OC and EC measurements are protocol dependent, leading to uncertainties in their quantification. In this study, more than 1300 Hong Kong samples were analyzed using both National Institute for Occupational Safety and Health (NIOSH) thermal optical transmittance (TOT) and Interagency Monitoring of Protected Visual Environment (IMPROVE) thermal optical reflectance (TOR) protocols to explore the cause of EC disagreement between the two protocols. EC discrepancy mainly (83 %) arises from a difference in peak inert mode temperature, which determines the allocation of OC4NSH, while the rest (17 %) is attributed to a difference in the optical method (transmittance vs. reflectance) applied for the charring correction. Evidence shows that the magnitude of the EC discrepancy is positively correlated with the intensity of the biomass burning signal, whereby biomass burning increases the fraction of OC4NSH and widens the disagreement in the inter-protocol EC determination. It is also found that the EC discrepancy is positively correlated with the abundance of metal oxide in the samples. Two approaches (M1 and M2) that translate NIOSH TOT OC and EC data into IMPROVE TOR OC and EC data are proposed. M1 uses direct relationship between ECNSH_TOT and ECIMP_TOR for reconstruction: M1 : ECIMP_TOR = a × ECNSH_TOT + b; while M2 deconstructs ECIMP_TOR into several terms based on analysis principles and applies regression only on the unknown terms: M2 : ECIMP_TOR = AECNSH + OC4NSH - (a × PCNSH_TOR + b), where AECNSH, apparent EC by the NIOSH protocol, is the carbon that evolves in the He-O2 analysis stage, OC4NSH is the carbon that evolves at the fourth temperature step of the pure helium analysis stage of NIOSH, and PCNSH_TOR is the pyrolyzed carbon as determined by the NIOSH protocol. The implementation of M1 to all urban site data (without considering seasonal specificity) yields the following equation: M1(urban data) : ECIMP_TOR = 2.20 × ECNSH_TOT - 0.05. While both M1 and M2 are acceptable, M2 with site-specific parameters provides the best reconstruction performance. Secondary OC (SOC) estimation using OC and EC by the two protocols is compared. An analysis of the usability of reconstructed ECIMP_TOR and OCIMP_TOR suggests that the reconstructed values are not suitable for SOC estimation due to the poor reconstruction of the OC / EC ratio.

  11. The Karlsruhe Metabolomics and Nutrition (KarMeN) Study: Protocol and Methods of a Cross-Sectional Study to Characterize the Metabolome of Healthy Men and Women

    PubMed Central

    Kriebel, Anita; Dörr, Claudia; Bandt, Susanne; Rist, Manuela; Roth, Alexander; Hummel, Eva; Kulling, Sabine; Hoffmann, Ingrid; Watzl, Bernhard

    2016-01-01

    Background The human metabolome is influenced by various intrinsic and extrinsic factors. A precondition to identify such biomarkers is the comprehensive understanding of the composition and variability of the metabolome of healthy humans. Sample handling aspects have an important impact on the composition of the metabolome; therefore, it is crucial for any metabolomics study to standardize protocols on sample collection, preanalytical sample handling, storage, and analytics to keep the nonbiological variability as low as possible. Objective The main objective of the KarMeN study is to analyze the human metabolome in blood and urine by targeted and untargeted metabolite profiling (gas chromatography-mass spectrometry [GC-MS], GC×GC-MS, liquid chromatography-mass spectrometry [LC-MS/MS], and1H nuclear magnetic resonance [NMR] spectroscopy) and to determine the impact of sex, age, body composition, diet, and physical activity on metabolite profiles of healthy women and men. Here, we report the outline of the study protocol with special regard to all aspects that should be considered in studies applying metabolomics. Methods Healthy men and women, aged 18 years or older, were recruited. In addition to a number of anthropometric (height, weight, body mass index, waist circumference, body composition), clinical (blood pressure, electrocardiogram, blood and urine clinical chemistry) and functional parameters (lung function, arterial stiffness), resting metabolic rate, physical activity, fitness, and dietary intake were assessed, and 24-hour urine, fasting spot urine, and plasma samples were collected. Standard operating procedures were established for all steps of the study design. Using different analytical techniques (LC-MS, GC×GC-MS,1H NMR spectroscopy), metabolite profiles of urine and plasma were determined. Data will be analyzed using univariate and multivariate as well as predictive modeling methods. Results The project was funded in 2011 and enrollment was carried out between March 2012 and July 2013. A total of 301 volunteers were eligible to participate in the study. Metabolite profiling of plasma and urine samples has been completed and data analysis is currently underway. Conclusions We established the KarMeN study applying a broad set of clinical and physiological examinations with a high degree of standardization. Our experimental approach of combining scheduled timing of examinations and sampling with the multiplatform approach (GC×GC-MS, GC-MS, LC-MS/MS, and1H NMR spectroscopy) will enable us to differentiate between current and long-term effects of diet and physical activity on metabolite profiles, while enabling us at the same time to consider confounders such as age and sex in the KarMeN study. Trial Registration German Clinical Trials Register DRKS00004890; https://drks-neu.uniklinik-freiburg.de/drks_web/navigate.do? navigationId=trial.HTML&TRIAL_ID=DRKS00004890 (Archived by WebCite at http://www.webcitation.org/6iyM8dMtx) PMID:27421387

  12. A multi-analytical approach for the characterization of wall painting materials on contemporary buildings

    NASA Astrophysics Data System (ADS)

    Magrini, Donata; Bracci, Susanna; Cantisani, Emma; Conti, Claudia; Rava, Antonio; Sansonetti, Antonio; Shank, Will; Colombini, MariaPerla

    2017-02-01

    Samples from Keith Haring's wall painting of the Necker Children Hospital in Paris were studied by a multi-analytical protocol. X-ray fluorescence (XRF), powder X-ray diffraction (XRDP), Electron microscope (SEM-EDS), Infrared and Raman spectroscopy (μ-FT-IR and μ-Raman) measurements were performed in order to characterize the materials and to identify the art technique used to produce this contemporary work. Materials from the mural suffered from severe detachments of materials and several fragments were found on the ground beneath. Some of these fragments, which were representative of the whole palette and stratigraphic sequence, were collected and studied. The fragments were sufficiently large to enable non-invasive measurements to be performed in order to characterize the materials. A comparison of the data of the techniques applied revealed that Haring's palette was composed of organic pigments such as Naphtol red, phthalocyanine blue and green and Hansa yellow, in accordance with those used previously by the artist in other painted murals.

  13. An UPLC-MS/MS method for separation and accurate quantification of tamoxifen and its metabolites isomers.

    PubMed

    Arellano, Cécile; Allal, Ben; Goubaa, Anwar; Roché, Henri; Chatelut, Etienne

    2014-11-01

    A selective and accurate analytical method is needed to quantify tamoxifen and its phase I metabolites in a prospective clinical protocol, for evaluation of pharmacokinetic parameters of tamoxifen and its metabolites in adjuvant treatment of breast cancer. The selectivity of the analytical method is a fundamental criteria to allow the quantification of the main active metabolites (Z)-isomers from (Z)'-isomers. An UPLC-MS/MS method was developed and validated for the quantification of (Z)-tamoxifen, (Z)-endoxifen, (E)-endoxifen, Z'-endoxifen, (Z)'-endoxifen, (Z)-4-hydroxytamoxifen, (Z)-4'-hydroxytamoxifen, N-desmethyl tamoxifen, and tamoxifen-N-oxide. The validation range was set between 0.5ng/mL and 125ng/mL for 4-hydroxytamoxifen and endoxifen isomers, and between 12.5ng/mL and 300ng/mL for tamoxifen, tamoxifen N-desmethyl and tamoxifen-N-oxide. The application to patient plasma samples was performed. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hendron, R.; Engebrecht, C.

    The House Simulation Protocol document was developed to track and manage progress toward Building America's multi-year, average whole-building energy reduction research goals for new construction and existing homes, using a consistent analytical reference point. This report summarizes the guidelines for developing and reporting these analytical results in a consistent and meaningful manner for all home energy uses using standard operating conditions.

  15. Accuracy verification and identification of matrix effects. The College of American Pathologists' Protocol.

    PubMed

    Eckfeldt, J H; Copeland, K R

    1993-04-01

    Proficiency testing using stabilized control materials has been used for decades as a means of monitoring and improving performance in the clinical laboratory. Often, the commonly used proficiency testing materials exhibit "matrix effects" that cause them to behave differently from fresh human specimens in certain clinical analytic systems. Because proficiency testing is the primary method in which regulatory agencies have chosen to evaluate clinical laboratory performance, the College of American Pathologists (CAP) has proposed guidelines for investigating the influence of matrix effects on their Survey results. The purpose of this investigation was to determine the feasibility, usefulness, and potential problems associated with this CAP Matrix Effect Analytical Protocol, in which fresh patient specimens and CAP proficiency specimens are analyzed simultaneously by a field method and a definitive, reference, or other comparative method. The optimal outcome would be that both the fresh human and CAP Survey specimens agree closely with the comparative method result. However, this was not always the case. Using several different analytic configurations, we were able to demonstrate matrix and calibration biases for several of the analytes investigated.

  16. Analytical Performance Characteristics of the Cepheid GeneXpert Ebola Assay for the Detection of Ebola Virus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pinsky, Benjamin A.; Sahoo, Malaya K.; Sandlund, Johanna

    The recently developed Xpert® Ebola Assay is a novel nucleic acid amplification test for simplified detection of Ebola virus (EBOV) in whole blood and buccal swab samples. The assay targets sequences in two EBOV genes, lowering the risk for new variants to escape detection in the test. The objective of this report is to present analytical characteristics of the Xpert® Ebola Assay on whole blood samples. Our study evaluated the assay’s analytical sensitivity, analytical specificity, inclusivity and exclusivity performance in whole blood specimens. EBOV RNA, inactivated EBOV, and infectious EBOV were used as targets. The dynamic range of the assay,more » the inactivation of virus, and specimen stability were also evaluated. The lower limit of detection (LoD) for the assay using inactivated virus was estimated to be 73 copies/mL (95% CI: 51–97 copies/mL). The LoD for infectious virus was estimated to be 1 plaque-forming unit/mL, and for RNA to be 232 copies/mL (95% CI 163–302 copies/mL). The assay correctly identified five different Ebola viruses, Yambuku-Mayinga, Makona-C07, Yambuku-Ecran, Gabon-Ilembe, and Kikwit-956210, and correctly excluded all non-EBOV isolates tested. The conditions used by Xpert® Ebola for inactivation of infectious virus reduced EBOV titer by ≥6 logs. In conclusion, we found the Xpert® Ebola Assay to have high analytical sensitivity and specificity for the detection of EBOV in whole blood. It offers ease of use, fast turnaround time, and remote monitoring. The test has an efficient viral inactivation protocol, fulfills inclusivity and exclusivity criteria, and has specimen stability characteristics consistent with the need for decentralized testing. The simplicity of the assay should enable testing in a wide variety of laboratory settings, including remote laboratories that are not capable of performing highly complex nucleic acid amplification tests, and during outbreaks where time to detection is critical.« less

  17. Analytical Performance Characteristics of the Cepheid GeneXpert Ebola Assay for the Detection of Ebola Virus

    DOE PAGES

    Pinsky, Benjamin A.; Sahoo, Malaya K.; Sandlund, Johanna; ...

    2015-11-12

    The recently developed Xpert® Ebola Assay is a novel nucleic acid amplification test for simplified detection of Ebola virus (EBOV) in whole blood and buccal swab samples. The assay targets sequences in two EBOV genes, lowering the risk for new variants to escape detection in the test. The objective of this report is to present analytical characteristics of the Xpert® Ebola Assay on whole blood samples. Our study evaluated the assay’s analytical sensitivity, analytical specificity, inclusivity and exclusivity performance in whole blood specimens. EBOV RNA, inactivated EBOV, and infectious EBOV were used as targets. The dynamic range of the assay,more » the inactivation of virus, and specimen stability were also evaluated. The lower limit of detection (LoD) for the assay using inactivated virus was estimated to be 73 copies/mL (95% CI: 51–97 copies/mL). The LoD for infectious virus was estimated to be 1 plaque-forming unit/mL, and for RNA to be 232 copies/mL (95% CI 163–302 copies/mL). The assay correctly identified five different Ebola viruses, Yambuku-Mayinga, Makona-C07, Yambuku-Ecran, Gabon-Ilembe, and Kikwit-956210, and correctly excluded all non-EBOV isolates tested. The conditions used by Xpert® Ebola for inactivation of infectious virus reduced EBOV titer by ≥6 logs. In conclusion, we found the Xpert® Ebola Assay to have high analytical sensitivity and specificity for the detection of EBOV in whole blood. It offers ease of use, fast turnaround time, and remote monitoring. The test has an efficient viral inactivation protocol, fulfills inclusivity and exclusivity criteria, and has specimen stability characteristics consistent with the need for decentralized testing. The simplicity of the assay should enable testing in a wide variety of laboratory settings, including remote laboratories that are not capable of performing highly complex nucleic acid amplification tests, and during outbreaks where time to detection is critical.« less

  18. ColiSense, today's sample today: A rapid on-site detection of β-D-Glucuronidase activity in surface water as a surrogate for E. coli.

    PubMed

    Heery, Brendan; Briciu-Burghina, Ciprian; Zhang, Dian; Duffy, Gillian; Brabazon, Dermot; O'Connor, Noel; Regan, Fiona

    2016-01-01

    A sensitive field-portable fluorimeter with incubating capability and triplicate sample chambers was designed and built. The system was optimised for the on-site analysis of E. coli in recreational waters using fluorescent based enzyme assays. The target analyte was β-D-Glucuronidase (GUS) which hydrolyses a synthetic substrate 6-Chloro-4-Methyl-Umbelliferyl-β-D-Glucuronide (6-CMUG) to release the fluorescent molecule 6-Chloro-4-Methyl-Umbelliferyl (6-CMU). The system was calibrated with 6-CMU standards. A LOD of 5 nM and a resolution of less than 1 nM was determined while enzyme kinetic tests showed detection of activities below 1 pmol min(-1) mL(-1) of sample. A field portable sample preparation, enzyme extraction protocol and continuous assay were applied with the system to analyse freshwater and marine samples. Results from a one day field trial are shown which demonstrated the ability of the system to deliver results on-site within a 75 min period. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Performance evaluation of a mitogenome capture and Illumina sequencing protocol using non-probative, case-type skeletal samples: Implications for the use of a positive control in a next-generation sequencing procedure.

    PubMed

    Marshall, Charla; Sturk-Andreaggi, Kimberly; Daniels-Higginbotham, Jennifer; Oliver, Robert Sean; Barritt-Ross, Suzanne; McMahon, Timothy P

    2017-11-01

    Next-generation ancient DNA technologies have the potential to assist in the analysis of degraded DNA extracted from forensic specimens. Mitochondrial genome (mitogenome) sequencing, specifically, may be of benefit to samples that fail to yield forensically relevant genetic information using conventional PCR-based techniques. This report summarizes the Armed Forces Medical Examiner System's Armed Forces DNA Identification Laboratory's (AFMES-AFDIL) performance evaluation of a Next-Generation Sequencing protocol for degraded and chemically treated past accounting samples. The procedure involves hybridization capture for targeted enrichment of mitochondrial DNA, massively parallel sequencing using Illumina chemistry, and an automated bioinformatic pipeline for forensic mtDNA profile generation. A total of 22 non-probative samples and associated controls were processed in the present study, spanning a range of DNA quantity and quality. Data were generated from over 100 DNA libraries by ten DNA analysts over the course of five months. The results show that the mitogenome sequencing procedure is reliable and robust, sensitive to low template (one ng control DNA) as well as degraded DNA, and specific to the analysis of the human mitogenome. Haplotypes were overall concordant between NGS replicates and with previously generated Sanger control region data. Due to the inherent risk for contamination when working with low-template, degraded DNA, a contamination assessment was performed. The consumables were shown to be void of human DNA contaminants and suitable for forensic use. Reagent blanks and negative controls were analyzed to determine the background signal of the procedure. This background signal was then used to set analytical and reporting thresholds, which were designated at 4.0X (limit of detection) and 10.0X (limit of quantiation) average coverage across the mitogenome, respectively. Nearly all human samples exceeded the reporting threshold, although coverage was reduced in chemically treated samples resulting in a ∼58% passing rate for these poor-quality samples. A concordance assessment demonstrated the reliability of the NGS data when compared to known Sanger profiles. One case sample was shown to be mixed with a co-processed sample and two reagent blanks indicated the presence of DNA above the analytical threshold. This contamination was attributed to sequencing crosstalk from simultaneously sequenced high-quality samples to include the positive control. Overall this study demonstrated that hybridization capture and Illumina sequencing provide a viable method for mitogenome sequencing of degraded and chemically treated skeletal DNA samples, yet may require alternative measures of quality control. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Mass-spectrometric mining of Hadean zircons by automated SHRIMP multi-collector and single-collector U/Pb zircon age dating: The first 100,000 grains

    NASA Astrophysics Data System (ADS)

    Holden, Peter; Lanc, Peter; Ireland, Trevor R.; Harrison, T. Mark; Foster, John J.; Bruce, Zane

    2009-09-01

    The identification and retrieval of a large population of ancient zircons (>4 Ga; Hadean) is of utmost priority if models of the early evolution of Earth are to be rigorously tested. We have developed a rapid and accurate U-Pb zircon age determination protocol utilizing a fully automated multi-collector ion microprobe, the ANU SHRIMP II, to screen and date these zircons. Unattended data acquisition relies on the calibration of a digitized sample map to the Sensitive High Resolution Ion MicroProbe (SHRIMP) sample-stage co-ordinate system. High precision positioning of individual grains can be produced through optical image processing of a specified mount location. The focal position of the mount can be optimized through a correlation between secondary-ion steering and the spot position on the target. For the Hadean zircon project, sample mounts are photographed and sample locations (normally grain centers) are determined off-line. The sample is loaded, reference points calibrated, and the target positions are then visited sequentially. In SHRIMP II multiple-collector mode, zircons are initially screened (ca. 5 s data acquisition) through their 204Pb corrected 207Pb/206Pb ratio; suitable candidates are then analyzed in a longer routine to obtain better measurement statistics, U/Pb, and concentration data. In SHRIMP I and SHRIMP RG, we have incorporated the automated analysis protocol to single-collector measurements. These routines have been used to analyze over 100,000 zircons from the Jack Hills quartzite. Of these, ca. 7%, have an age greater than 3.8 Ga, the oldest grain being 4372 +/- 6 Ma (2[sigma]), and this age is part of a group of analyses around 4350 Ma which we interpret as the age when continental crust first began to coalesce in this region. In multi-collector mode, the analytical time taken for a single mount with 400 zircons is approximately 6 h; whereas in single-collector mode, the analytical time is ca. 17 h. With this productivity, we can produce significant numbers of zircons for statistically limited studies including correlations between age and morphology, mineral-inclusion paragenesis, as well as isotopic studies including Hf and O isotopic compositions, Pu-Xe, and Sm-Nd isotopes.

  1. Comparison of three methods of DNA extraction from peripheral blood mononuclear cells and lung fragments of equines.

    PubMed

    Santos, E M; Paula, J F R; Motta, P M C; Heinemann, M B; Leite, R C; Haddad, J P A; Del Puerto, H L; Reis, J K P

    2010-08-17

    We compared three different protocols for DNA extraction from horse peripheral blood mononuclear cells (PBMC) and lung fragments, determining average final DNA concentration, purity, percentage of PCR amplification using beta-actin, and cost. Thirty-four samples from PBMC, and 33 samples from lung fragments were submitted to DNA extraction by three different protocols. Protocol A consisted of a phenol-chloroform and isoamylic alcohol extraction, Protocol B used alkaline extraction with NaOH, and Protocol C used the DNAzol((R)) reagent kit. Protocol A was the best option for DNA extraction from lung fragments, producing high DNA concentrations, with high sensitivity in PCR amplification (100%), followed by Protocols C and B. On the other hand, for PBMC samples, Protocol B gave the highest sensitivity in PCR amplification (100%), followed by Protocols C and A. We conclude that Protocol A should be used for PCR diagnosis from lung fragment samples, while Protocol B should be used for PBMC.

  2. Guidelines and sample protocol for sampling forest gaps.

    Treesearch

    J.R. Runkle

    1992-01-01

    A protocol for sampling forest canopy gaps is presented. Methods used in published gap studies are reviewed. The sample protocol will be useful in developing a broader understanding of forest structure and dynamics through comparative studies across different forest ecosystems.

  3. Determination of doping peptides via solid-phase microelution and accurate-mass quadrupole time-of-flight LC-MS.

    PubMed

    Cuervo, Darío; Loli, Cynthia; Fernández-Álvarez, María; Muñoz, Gloria; Carreras, Daniel

    2017-10-15

    A complete analytical protocol for the determination of 25 doping-related peptidic drugs and 3 metabolites in urine was developed by means of accurate-mass quadrupole time-of-flight (Q-TOF) LC-MS analysis following solid-phase extraction (SPE) on microplates and conventional SPE pre-treatment for initial testing and confirmation, respectively. These substances included growth hormone releasing factors, gonadotropin releasing factors and anti-diuretic hormones, with molecular weights ranging from 540 to 1320Da. Optimal experimental conditions were stablished after investigation of different parameters concerning sample preparation and instrumental analysis. Weak cation exchange SPE followed by C18 HPLC chromatography and accurate mass detection provided the required sensitivity and selectivity for all the target peptides under study. 2mg SPE on 96-well microplates can be used in combination with full scan MS detection for the initial testing, thus providing a fast, cost-effective and high-throughput protocol for the processing of a large batch of samples simultaneously. On the other hand, extraction on 30mg SPE cartridges and subsequent target MS/MS determination was the protocol of choice for confirmatory purposes. The methodology was validated in terms of selectivity, recovery, matrix effect, precision, sensitivity (limit of detection, LOD), cross contamination, carryover, robustness and stability. Recoveries ranged from 6 to 70% (microplates) and 17-95% (cartridges), with LODs from 0.1 to 1ng/mL. The suitability of the method was assessed by analyzing different spiked or excreted urines containing some of the target substances. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. An ultra low-power and traffic-adaptive medium access control protocol for wireless body area network.

    PubMed

    Ullah, Sana; Kwak, Kyung Sup

    2012-06-01

    Wireless Body Area Network (WBAN) consists of low-power, miniaturized, and autonomous wireless sensor nodes that enable physicians to remotely monitor vital signs of patients and provide real-time feedback with medical diagnosis and consultations. It is the most reliable and cheaper way to take care of patients suffering from chronic diseases such as asthma, diabetes and cardiovascular diseases. Some of the most important attributes of WBAN is low-power consumption and delay. This can be achieved by introducing flexible duty cycling techniques on the energy constraint sensor nodes. Stated otherwise, low duty cycle nodes should not receive frequent synchronization and control packets if they have no data to send/receive. In this paper, we introduce a Traffic-adaptive MAC protocol (TaMAC) by taking into account the traffic information of the sensor nodes. The protocol dynamically adjusts the duty cycle of the sensor nodes according to their traffic-patterns, thus solving the idle listening and overhearing problems. The traffic-patterns of all sensor nodes are organized and maintained by the coordinator. The TaMAC protocol is supported by a wakeup radio that is used to accommodate emergency and on-demand events in a reliable manner. The wakeup radio uses a separate control channel along with the data channel and therefore it has considerably low power consumption requirements. Analytical expressions are derived to analyze and compare the performance of the TaMAC protocol with the well-known beacon-enabled IEEE 802.15.4 MAC, WiseMAC, and SMAC protocols. The analytical derivations are further validated by simulation results. It is shown that the TaMAC protocol outperforms all other protocols in terms of power consumption and delay.

  5. Prevalence of Pre-Analytical Errors in Clinical Chemistry Diagnostic Labs in Sulaimani City of Iraqi Kurdistan

    PubMed Central

    2017-01-01

    Background Laboratory testing is roughly divided into three phases: a pre-analytical phase, an analytical phase and a post-analytical phase. Most analytical errors have been attributed to the analytical phase. However, recent studies have shown that up to 70% of analytical errors reflect the pre-analytical phase. The pre-analytical phase comprises all processes from the time a laboratory request is made by a physician until the specimen is analyzed at the lab. Generally, the pre-analytical phase includes patient preparation, specimen transportation, specimen collection and storage. In the present study, we report the first comprehensive assessment of the frequency and types of pre-analytical errors at the Sulaimani diagnostic labs in Iraqi Kurdistan. Materials and Methods Over 2 months, 5500 venous blood samples were observed in 10 public diagnostic labs of Sulaimani City. The percentages of rejected samples and types of sample inappropriateness were evaluated. The percentage of each of the following pre-analytical errors were recorded: delay in sample transportation, clotted samples, expired reagents, hemolyzed samples, samples not on ice, incorrect sample identification, insufficient sample, tube broken in centrifuge, request procedure errors, sample mix-ups, communication conflicts, misinterpreted orders, lipemic samples, contaminated samples and missed physician’s request orders. The difference between the relative frequencies of errors observed in the hospitals considered was tested using a proportional Z test. In particular, the survey aimed to discover whether analytical errors were recorded and examine the types of platforms used in the selected diagnostic labs. Results The analysis showed a high prevalence of improper sample handling during the pre-analytical phase. In appropriate samples, the percentage error was as high as 39%. The major reasons for rejection were hemolyzed samples (9%), incorrect sample identification (8%) and clotted samples (6%). Most quality control schemes at Sulaimani hospitals focus only on the analytical phase, and none of the pre-analytical errors were recorded. Interestingly, none of the labs were internationally accredited; therefore, corrective actions are needed at these hospitals to ensure better health outcomes. Internal and External Quality Assessment Schemes (EQAS) for the pre-analytical phase at Sulaimani clinical laboratories should be implemented at public hospitals. Furthermore, lab personnel, particularly phlebotomists, need continuous training on the importance of sample quality to obtain accurate test results. PMID:28107395

  6. Prevalence of Pre-Analytical Errors in Clinical Chemistry Diagnostic Labs in Sulaimani City of Iraqi Kurdistan.

    PubMed

    Najat, Dereen

    2017-01-01

    Laboratory testing is roughly divided into three phases: a pre-analytical phase, an analytical phase and a post-analytical phase. Most analytical errors have been attributed to the analytical phase. However, recent studies have shown that up to 70% of analytical errors reflect the pre-analytical phase. The pre-analytical phase comprises all processes from the time a laboratory request is made by a physician until the specimen is analyzed at the lab. Generally, the pre-analytical phase includes patient preparation, specimen transportation, specimen collection and storage. In the present study, we report the first comprehensive assessment of the frequency and types of pre-analytical errors at the Sulaimani diagnostic labs in Iraqi Kurdistan. Over 2 months, 5500 venous blood samples were observed in 10 public diagnostic labs of Sulaimani City. The percentages of rejected samples and types of sample inappropriateness were evaluated. The percentage of each of the following pre-analytical errors were recorded: delay in sample transportation, clotted samples, expired reagents, hemolyzed samples, samples not on ice, incorrect sample identification, insufficient sample, tube broken in centrifuge, request procedure errors, sample mix-ups, communication conflicts, misinterpreted orders, lipemic samples, contaminated samples and missed physician's request orders. The difference between the relative frequencies of errors observed in the hospitals considered was tested using a proportional Z test. In particular, the survey aimed to discover whether analytical errors were recorded and examine the types of platforms used in the selected diagnostic labs. The analysis showed a high prevalence of improper sample handling during the pre-analytical phase. In appropriate samples, the percentage error was as high as 39%. The major reasons for rejection were hemolyzed samples (9%), incorrect sample identification (8%) and clotted samples (6%). Most quality control schemes at Sulaimani hospitals focus only on the analytical phase, and none of the pre-analytical errors were recorded. Interestingly, none of the labs were internationally accredited; therefore, corrective actions are needed at these hospitals to ensure better health outcomes. Internal and External Quality Assessment Schemes (EQAS) for the pre-analytical phase at Sulaimani clinical laboratories should be implemented at public hospitals. Furthermore, lab personnel, particularly phlebotomists, need continuous training on the importance of sample quality to obtain accurate test results.

  7. Biological diagnosis of von Willebrand disease: analytical characteristics of Innovance vWF:Ac assay kit on STA-R Evolution Expert series analyzer (Stago).

    PubMed

    Florin, Cécile; Garraud, Olivier; Molliex, Serge; Tardy, Brigitte; Campos, Lydia; Scherrer, Carine

    2016-06-01

    The Innovance VWF:Ac test (Siemens) has the particularity to assess the binding capacity of von Willebrand factor (VWF) to recombinant platelet GPIb mutated in the absence of ristocetin. Our study aimed to evaluate and validate according to standard NF EN ISO 15189 the original protocol adaptation on STA-R Evolution series analyser (Diagnostica Stago). We evaluated the performance in terms of imprecision and we validate additional parameters necessary in range B as recommended by the SH GTA 04 (Cofrac). We compared the new assay with the reference assay: ristocetin cofactor activity (VWF:RCo) performed on the BCS-XP analyser by testing retrospectively samples from 82 healthy normal subjects and 61 patients with von Willebrand disease (VWD). This new assay is consistent with objectives set in terms of imprecision with CV around 4%. Excepted limit of quantification higher, additional parameters evaluated in range B have been validated. The Innovance VWF: Ac assay allowed the detection of all deficits of VWF already detected by the VWF:RCo test on the BCS-XP. This adjustment on STA-R analyser therefore has satisfactory analytical performance criteria. Apart from the limit of quantification, this reagent can be used according to the recommendations specified in the original protocol adaptation. Its performance and compatibility with the spot measurement allow the diagnosis and therapeutic monitoring of VWD according to current requirements and guidelines.

  8. A slotted access control protocol for metropolitan WDM ring networks

    NASA Astrophysics Data System (ADS)

    Baziana, P. A.; Pountourakis, I. E.

    2009-03-01

    In this study we focus on the serious scalability problems that many access protocols for WDM ring networks introduce due to the use of a dedicated wavelength per access node for either transmission or reception. We propose an efficient slotted MAC protocol suitable for WDM ring metropolitan area networks. The proposed network architecture employs a separate wavelength for control information exchange prior to the data packet transmission. Each access node is equipped with a pair of tunable transceivers for data communication and a pair of fixed tuned transceivers for control information exchange. Also, each access node includes a set of fixed delay lines for synchronization reasons; to keep the data packets, while the control information is processed. An efficient access algorithm is applied to avoid both the data wavelengths and the receiver collisions. In our protocol, each access node is capable of transmitting and receiving over any of the data wavelengths, facing the scalability issues. Two different slot reuse schemes are assumed: the source and the destination stripping schemes. For both schemes, performance measures evaluation is provided via an analytic model. The analytical results are validated by a discrete event simulation model that uses Poisson traffic sources. Simulation results show that the proposed protocol manages efficient bandwidth utilization, especially under high load. Also, comparative simulation results prove that our protocol achieves significant performance improvement as compared with other WDMA protocols which restrict transmission over a dedicated data wavelength. Finally, performance measures evaluation is explored for diverse numbers of buffer size, access nodes and data wavelengths.

  9. Fast liquid chromatographic-tandem mass spectrometric method using mixed-mode phase chromatography and solid phase extraction for the determination of 12 mono-hydroxylated brominated diphenyl ethers in human serum.

    PubMed

    Petropoulou, Syrago-Styliani E; Duong, Wendy; Petreas, Myrto; Park, June-Soo

    2014-08-22

    Hydroxylated polybrominated diphenyl ethers (OH-PBDEs) are formed from the oxidative metabolism of polybrominated diphenyl ethers (PBDEs) in humans, rats and mice, but their quantitation in human blood and other matrices with liquid chromatography-mass spectrometric techniques has been a challenge. In this study, a novel analytical method was developed and validated using only 250 μL of human serum for the quantitation of twelve OH-PBDEs, fully chromatographically separated in a 15 min analytical run. This method includes two novel approaches: an enzymatic hydrolysis procedure and a chromatographic separation using a mixed mode chromatography column. The enzymatic hydrolysis (EH) was found critical for 4'-OH-BDE17, which was not detectable without it. For the sample clean up, a solid phase extraction protocol was developed and validated for the extraction of the 12 congeners from human serum. In addition, for the first time baseline resolution of two components was achieved that correspond to a single peak previously identified as 6'-OH-BDE99. The method was validated for linearity, accuracy, precision, matrix effects, limit of quantification, limit of detection, sample stability and overall efficiency. Recoveries (absolute and relative) ranged from 66 to 130% with relative standard deviations <21% for all analytes. Limit of detection and quantitation ranged from 4 to 90 pg mL(-1) and 6-120 pg mL(-1), respectively, with no carry over effects. This method was applied in ten commercially available human serum samples from the general US population. The mean values of the congeners detected in all samples are 4'-OH-BDE17 (34.2 pg mL(-1)), 4-OH-BDE42 (33.9 pg mL(-1)), 5-OH-BDE47 (17.5 pg mL(-1)) and 4'-OH-BDE49 (12.4 pg mL(-1)). Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Chemical Functionalization of Plasmonic Surface Biosensors: A Tutorial Review on Issues, Strategies, and Costs

    PubMed Central

    2017-01-01

    In an ideal plasmonic surface sensor, the bioactive area, where analytes are recognized by specific biomolecules, is surrounded by an area that is generally composed of a different material. The latter, often the surface of the supporting chip, is generally hard to be selectively functionalized, with respect to the active area. As a result, cross talks between the active area and the surrounding one may occur. In designing a plasmonic sensor, various issues must be addressed: the specificity of analyte recognition, the orientation of the immobilized biomolecule that acts as the analyte receptor, and the selectivity of surface coverage. The objective of this tutorial review is to introduce the main rational tools required for a correct and complete approach to chemically functionalize plasmonic surface biosensors. After a short introduction, the review discusses, in detail, the most common strategies for achieving effective surface functionalization. The most important issues, such as the orientation of active molecules and spatial and chemical selectivity, are considered. A list of well-defined protocols is suggested for the most common practical situations. Importantly, for the reported protocols, we also present direct comparisons in term of costs, labor demand, and risk vs benefit balance. In addition, a survey of the most used characterization techniques necessary to validate the chemical protocols is reported. PMID:28796479

  11. Improving inference for aerial surveys of bears: The importance of assumptions and the cost of unnecessary complexity.

    PubMed

    Schmidt, Joshua H; Wilson, Tammy L; Thompson, William L; Reynolds, Joel H

    2017-07-01

    Obtaining useful estimates of wildlife abundance or density requires thoughtful attention to potential sources of bias and precision, and it is widely understood that addressing incomplete detection is critical to appropriate inference. When the underlying assumptions of sampling approaches are violated, both increased bias and reduced precision of the population estimator may result. Bear ( Ursus spp.) populations can be difficult to sample and are often monitored using mark-recapture distance sampling (MRDS) methods, although obtaining adequate sample sizes can be cost prohibitive. With the goal of improving inference, we examined the underlying methodological assumptions and estimator efficiency of three datasets collected under an MRDS protocol designed specifically for bears. We analyzed these data using MRDS, conventional distance sampling (CDS), and open-distance sampling approaches to evaluate the apparent bias-precision tradeoff relative to the assumptions inherent under each approach. We also evaluated the incorporation of informative priors on detection parameters within a Bayesian context. We found that the CDS estimator had low apparent bias and was more efficient than the more complex MRDS estimator. When combined with informative priors on the detection process, precision was increased by >50% compared to the MRDS approach with little apparent bias. In addition, open-distance sampling models revealed a serious violation of the assumption that all bears were available to be sampled. Inference is directly related to the underlying assumptions of the survey design and the analytical tools employed. We show that for aerial surveys of bears, avoidance of unnecessary model complexity, use of prior information, and the application of open population models can be used to greatly improve estimator performance and simplify field protocols. Although we focused on distance sampling-based aerial surveys for bears, the general concepts we addressed apply to a variety of wildlife survey contexts.

  12. Protocol for HER2 FISH Using a Non-cross-linking, Formalin-free Tissue Fixative to Combine Advantages of Cryo-preservation and Formalin Fixation

    PubMed Central

    Loibner, Martina; Oberauner-Wappis, Lisa; Viertler, Christian; Groelz, Daniel; Zatloukal, Kurt

    2017-01-01

    Morphologic assessment of formalin-fixed, paraffin-embedded (FFPE) tissue samples has been the gold standard for cancer diagnostics for decades due to its excellent preservation of morphology. Personalized medicine increasingly provides individually adapted and targeted therapies for characterized individual diseases enabled by combined morphological and molecular analytical technologies and diagnostics. Performance of morphologic and molecular assays from the same FFPE specimen is challenging because of the negative impact of formalin due to chemical modification and cross-linking of nucleic acids and proteins. A non-cross-linking, formalin-free tissue fixative has been recently developed to fulfil both requirements, i.e., to preserve morphology like FFPE and biomolecules like cryo-preservation. Since FISH is often required in combination with histopathology and molecular diagnostics, we tested the applicability of FISH protocols on tissues treated with this new fixative. We found that formalin post-fixation of histological sections of non-cross-linking, formalin-free and paraffin-embedded (NCFPE) breast cancer tissue generated equivalent results to those with FFPE tissue in human epidermal growth factor receptor 2 (HER2) FISH analysis. This protocol describes how a FISH assay originally developed and validated for FFPE tissue can be used for NCFPE tissues by a simple post-fixation step of histological sections. PMID:29364207

  13. Changes of Multiple Metal Accumulation (MMA) in New Orleans Soil: Preliminary Evaluation of Differences between Survey I (1992) and Survey II (2000)

    PubMed Central

    Mielke, Howard W.; Gonzales, Christopher; Powell, Eric; MielkeJr, Paul W.

    2005-01-01

    Soil metal surveys were conducted in Baltimore, MD (1976–1979), Minnesota (1981–1988) and most recently, New Orleans, LA (1989-present). The unique characteristic of New Orleans is that it has two surveys; Survey I was completed in 1992 and Survey II was completed in 2000. This paper seeks to determine if there is a perceptible change in the amount of metals during less than a decade that separated these surveys. The Survey I collection was 4,026 samples stratified by 283 census tracts. All samples were collected in residential neighborhoods at least one block from a busy street. The Survey II collection was 5,467 samples stratified by 286 census tracts (plus City Park). The Survey II collection included busy streets as a category of samples. For comparison, the busy street category of 1,078 samples was excluded from Survey II for a total of 4,388 samples. The extraction methods of the two surveys used the same protocol for strength of acid (1 M HNO3), shaker-time (2 hours), and room temperature (~22ºC). However, Survey II differed in amount of sample used in extraction. For Surveys I and II, 4.0g and 0.4g were used respectively. The same ICP-AES was used to measure 8 metals in both surveys. To evaluate the analytical results of the two methods, reference soil samples (n=36) from the Wageningen Evaluating Programs for Analytical Laboratories, International Soil-analytical Exchange (WEPAL; ISE) were used. The relationship between the 4.0 and 0.4 g results were linear and the Survey I results were adjusted for sample:acid ratio. Further evaluation was done by creating interpolated Multiple Metal Accumulation (MMA) maps based on the median MMA for each census tract. A new map was created by dividing Survey II MMA by Survey I MMA. The ratio indicates increases of soil metals in the inner city and decreases of soil metals in the outlying areas of Metropolitan New Orleans. Comparing fresh parent alluvium from the Mississippi River with urban soil metal quantities demonstrates that the soils of New Orleans have undergone a massive accumulation of metals. The preliminary results provide ideas about methods needed to further evaluate the changes between these surveys. PMID:16705833

  14. Interpreting and Reporting Radiological Water-Quality Data

    USGS Publications Warehouse

    McCurdy, David E.; Garbarino, John R.; Mullin, Ann H.

    2008-01-01

    This document provides information to U.S. Geological Survey (USGS) Water Science Centers on interpreting and reporting radiological results for samples of environmental matrices, most notably water. The information provided is intended to be broadly useful throughout the United States, but it is recommended that scientists who work at sites containing radioactive hazardous wastes need to consult additional sources for more detailed information. The document is largely based on recognized national standards and guidance documents for radioanalytical sample processing, most notably the Multi-Agency Radiological Laboratory Analytical Protocols Manual (MARLAP), and on documents published by the U.S. Environmental Protection Agency and the American National Standards Institute. It does not include discussion of standard USGS practices including field quality-control sample analysis, interpretive report policies, and related issues, all of which shall always be included in any effort by the Water Science Centers. The use of 'shall' in this report signifies a policy requirement of the USGS Office of Water Quality.

  15. Comprehensive profiling and marker identification in non-volatile citrus oil residues by mass spectrometry and nuclear magnetic resonance.

    PubMed

    Marti, Guillaume; Boccard, Julien; Mehl, Florence; Debrus, Benjamin; Marcourt, Laurence; Merle, Philippe; Delort, Estelle; Baroux, Lucie; Sommer, Horst; Rudaz, Serge; Wolfender, Jean-Luc

    2014-05-01

    The detailed characterization of cold-pressed lemon oils (CPLOs) is of great importance for the flavor and fragrance (F&F) industry. Since a control of authenticity by standard analytical techniques can be bypassed using elaborated adulterated oils to pretend a higher quality, a combination of advanced orthogonal methods has been developed. The present study describes a combined metabolomic approach based on UHPLC-TOF-MS profiling and (1)H NMR fingerprinting to highlight metabolite differences on a set of representative samples used in the F&F industry. A new protocol was set up and adapted to the use of CPLO residues. Multivariate analysis based on both fingerprinting methods showed significant chemical variations between Argentinian and Italian samples. Discriminating markers identified in mixtures belong to furocoumarins, flavonoids, terpenoids and fatty acids. Quantitative NMR revealed low citropten and high bergamottin content in Italian samples. The developed metabolomic approach applied to CPLO residues gives some new perspectives for authenticity assessment. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Evaluation of SDS depletion using an affinity spin column and IMS-MS detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hengel, Shawna M.; Floyd, Erica A.; Baker, Erin Shammel

    2012-11-01

    While the use of detergents is necessary for a variety of protein isolation preparation protocols, often prior to mass spectral (MS) analysis, they are not compatible with MS analysis due to ion suppression and adduct formation. This manuscript describes optimization of detergent removal, using commercially available SDS depletion spin columns containing an affinity resin, providing for both increased protein recovery and thorough SDS removal. Ion mobility spectrometry coupled with mass spectrometry (IMS-MS) allowed for a concurrent analysis of both analyte and detergent. In the case of both proteins and peptides, higher detergent concentrations than previously reported provided an increase ofmore » sample recovery; however there was a limit as SDS was detected by IMS-MS at higher levels of SDS indicating incomplete detergent depletion. The results also suggest optimal conditions for SDS removal are dependent on the sample concentration. Overall, this study provides a useful guide for proteomic studies where SDS is required for efficient sample preparation.« less

  17. Sample handling for mass spectrometric proteomic investigations of human urine.

    PubMed

    Petri, Anette Lykke; Høgdall, Claus; Christensen, Ib Jarle; Simonsen, Anja Hviid; T'jampens, Davy; Hellmann, Marja-Leena; Kjaer, Susanne Krüger; Fung, Eric T; Høgdall, Estrid

    2008-09-01

    Because of its non-invasive sample collection method, human urine is an attractive biological material both for discovering biomarkers and for use in future screening trials for different diseases. Before urine can be used for these applications, standardized protocols for sample handling that optimize protein stability are required. In this explorative study, we examine the influence of different urine collection methods, storage temperatures, storage times, and repetitive freeze-thaw procedures on the protein profiles obtained by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Prospectively collected urine samples from 11 women were collected as either morning or midday specimens. The effects of storage temperature, time to freezing, and freeze-thaw cycles were assessed by calculating the number, intensity, and reproducibility of peaks visualized by SELDI-TOF-MS. On the CM10 array, 122 peaks were detected and 28 peaks were found to be significantly different between urine types, storage temperature and time to freezing. On the IMAC-Cu array, 65 peaks were detected and 1 peak was found to be significantly different according to time to freezing. No significant differences were demonstrated for freeze-thaw cycles. Optimal handling and storage conditions are necessary in clinical urine proteomic investigations. Collection of urine with a single and consistently performed protocol is needed to reduce analytical bias. Collecting only one urine type, which is stored for a limited period at 4°C until freezing at -80°C prior to analysis will provide the most stable profiles. Copyright © 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Protocols for dry DNA storage and shipment at room temperature

    PubMed Central

    Ivanova, Natalia V; Kuzmina, Masha L

    2013-01-01

    The globalization of DNA barcoding will require core analytical facilities to develop cost-effective, efficient protocols for the shipment and archival storage of DNA extracts and PCR products. We evaluated three dry-state DNA stabilization systems: commercial Biomatrica® DNAstable® plates, home-made trehalose and polyvinyl alcohol (PVA) plates on 96-well panels of insect DNA stored at 56 °C and at room temperature. Controls included unprotected samples that were stored dry at room temperature and at 56 °C, and diluted samples held at 4 °C and at −20 °C. PCR and selective sequencing were performed over a 4-year interval to test the condition of DNA extracts. Biomatrica® provided better protection of DNA at 56 °C and at room temperature than trehalose and PVA, especially for diluted samples. PVA was the second best protectant after Biomatrica® at room temperature, whereas trehalose was the second best protectant at 56 °C. In spite of lower PCR success, the DNA stored at −20 °C yielded longer sequence reads and stronger signal, indicating that temperature is a crucial factor for DNA quality which has to be considered especially for long-term storage. Although it is premature to advocate a transition to DNA storage at room temperature, dry storage provides an additional layer of security for frozen samples, protecting them from degradation in the event of freezer failure. All three forms of DNA preservation enable shipment of dry DNA and PCR products between barcoding facilities. PMID:23789643

  19. Computing the Free Energy Barriers for Less by Sampling with a Coarse Reference Potential while Retaining Accuracy of the Target Fine Model.

    PubMed

    Plotnikov, Nikolay V

    2014-08-12

    Proposed in this contribution is a protocol for calculating fine-physics (e.g., ab initio QM/MM) free-energy surfaces at a high level of accuracy locally (e.g., only at reactants and at the transition state for computing the activation barrier) from targeted fine-physics sampling and extensive exploratory coarse-physics sampling. The full free-energy surface is still computed but at a lower level of accuracy from coarse-physics sampling. The method is analytically derived in terms of the umbrella sampling and the free-energy perturbation methods which are combined with the thermodynamic cycle and the targeted sampling strategy of the paradynamics approach. The algorithm starts by computing low-accuracy fine-physics free-energy surfaces from the coarse-physics sampling in order to identify the reaction path and to select regions for targeted sampling. Thus, the algorithm does not rely on the coarse-physics minimum free-energy reaction path. Next, segments of high-accuracy free-energy surface are computed locally at selected regions from the targeted fine-physics sampling and are positioned relative to the coarse-physics free-energy shifts. The positioning is done by averaging the free-energy perturbations computed with multistep linear response approximation method. This method is analytically shown to provide results of the thermodynamic integration and the free-energy interpolation methods, while being extremely simple in implementation. Incorporating the metadynamics sampling to the algorithm is also briefly outlined. The application is demonstrated by calculating the B3LYP//6-31G*/MM free-energy barrier for an enzymatic reaction using a semiempirical PM6/MM reference potential. These modifications allow computing the activation free energies at a significantly reduced computational cost but at the same level of accuracy compared to computing full potential of mean force.

  20. Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks

    NASA Astrophysics Data System (ADS)

    Nischkauer, Winfried; Vanhaecke, Frank; Bernacchi, Sébastien; Herwig, Christoph; Limbeck, Andreas

    2014-11-01

    Nebulising liquid samples and using the aerosol thus obtained for further analysis is the standard method in many current analytical techniques, also with inductively coupled plasma (ICP)-based devices. With such a set-up, quantification via external calibration is usually straightforward for samples with aqueous or close-to-aqueous matrix composition. However, there is a variety of more complex samples. Such samples can be found in medical, biological, technological and industrial contexts and can range from body fluids, like blood or urine, to fuel additives or fermentation broths. Specialized nebulizer systems or careful digestion and dilution are required to tackle such demanding sample matrices. One alternative approach is to convert the liquid into a dried solid and to use laser ablation for sample introduction. Up to now, this approach required the application of internal standards or matrix-adjusted calibration due to matrix effects. In this contribution, we show a way to circumvent these matrix effects while using simple external calibration for quantification. The principle of representative sampling that we propose uses radial line-scans across the dried residue. This compensates for centro-symmetric inhomogeneities typically observed in dried spots. The effectiveness of the proposed sampling strategy is exemplified via the determination of phosphorus in biochemical fermentation media. However, the universal viability of the presented measurement protocol is postulated. Detection limits using laser ablation-ICP-optical emission spectrometry were in the order of 40 μg mL- 1 with a reproducibility of 10 % relative standard deviation (n = 4, concentration = 10 times the quantification limit). The reported sensitivity is fit-for-purpose in the biochemical context described here, but could be improved using ICP-mass spectrometry, if future analytical tasks would require it. Trueness of the proposed method was investigated by cross-validation with conventional liquid measurements, and by analyzing IAEA-153 reference material (Trace Elements in Milk Powder); a good agreement with the certified value for phosphorus was obtained.

  1. Computing the Free Energy Barriers for Less by Sampling with a Coarse Reference Potential while Retaining Accuracy of the Target Fine Model

    PubMed Central

    2015-01-01

    Proposed in this contribution is a protocol for calculating fine-physics (e.g., ab initio QM/MM) free-energy surfaces at a high level of accuracy locally (e.g., only at reactants and at the transition state for computing the activation barrier) from targeted fine-physics sampling and extensive exploratory coarse-physics sampling. The full free-energy surface is still computed but at a lower level of accuracy from coarse-physics sampling. The method is analytically derived in terms of the umbrella sampling and the free-energy perturbation methods which are combined with the thermodynamic cycle and the targeted sampling strategy of the paradynamics approach. The algorithm starts by computing low-accuracy fine-physics free-energy surfaces from the coarse-physics sampling in order to identify the reaction path and to select regions for targeted sampling. Thus, the algorithm does not rely on the coarse-physics minimum free-energy reaction path. Next, segments of high-accuracy free-energy surface are computed locally at selected regions from the targeted fine-physics sampling and are positioned relative to the coarse-physics free-energy shifts. The positioning is done by averaging the free-energy perturbations computed with multistep linear response approximation method. This method is analytically shown to provide results of the thermodynamic integration and the free-energy interpolation methods, while being extremely simple in implementation. Incorporating the metadynamics sampling to the algorithm is also briefly outlined. The application is demonstrated by calculating the B3LYP//6-31G*/MM free-energy barrier for an enzymatic reaction using a semiempirical PM6/MM reference potential. These modifications allow computing the activation free energies at a significantly reduced computational cost but at the same level of accuracy compared to computing full potential of mean force. PMID:25136268

  2. Sampling protocol for post-landfall Deepwater Horizon oil release, Gulf of Mexico, 2010

    USGS Publications Warehouse

    Wilde, F.D.; Skrobialowski, S.C.; Hart, J.S.

    2010-01-01

    The protocols and procedures described in this report are designed to be used by U.S. Geological Survey (USGS) field teams for the collection of environmental data and samples in coastal areas affected by the 2010 Deepwater Horizon oil spill in the Gulf of Mexico. This sampling protocol focuses specifically on sampling for water, sediments, benthic invertebrates, and microorganisms (ambient bacterial populations) after shoreline arrival of petroleum-associated product on beach, barrier island, and wetland environments of the Gulf of Mexico coastal states. Deployment to sampling sites, site setup, and sample collection in these environments necessitates modifications to standard USGS sampling procedures in order to address the regulatory, logistical, and legal requirements associated with samples collected in oil-impacted coastal areas. This document, therefore, has been written as an addendum to the USGS National Field Manual for the Collection of Water-Quality Data (NFM) (http://pubs.water.usgs.gov/twri9A/), which provides the basis for training personnel in the use of standard USGS sampling protocols. The topics covered in this Gulf of Mexico oil-spill sampling protocol augment NFM protocols for field-deployment preparations, health and safety precautions, sampling and quality-assurance procedures, and decontamination requirements under potentially hazardous environmental conditions. Documentation procedures and maintenance of sample integrity by use of chain-of-custody procedures also are described in this protocol.

  3. Comprehensive genetic testing for female and male infertility using next-generation sequencing.

    PubMed

    Patel, Bonny; Parets, Sasha; Akana, Matthew; Kellogg, Gregory; Jansen, Michael; Chang, Chihyu; Cai, Ying; Fox, Rebecca; Niknazar, Mohammad; Shraga, Roman; Hunter, Colby; Pollock, Andrew; Wisotzkey, Robert; Jaremko, Malgorzata; Bisignano, Alex; Puig, Oscar

    2018-05-19

    To develop a comprehensive genetic test for female and male infertility in support of medical decisions during assisted reproductive technology (ART) protocols. We developed a next-generation sequencing (NGS) gene panel consisting of 87 genes including promoters, 5' and 3' untranslated regions, exons, and selected introns. In addition, sex chromosome aneuploidies and Y chromosome microdeletions were analyzed concomitantly using the same panel. The NGS panel was analytically validated by retrospective analysis of 118 genomic DNA samples with known variants in loci representative of female and male infertility. Our results showed analytical accuracy of > 99%, with > 98% sensitivity for single-nucleotide variants (SNVs) and > 91% sensitivity for insertions/deletions (indels). Clinical sensitivity was assessed with samples containing variants representative of male and female infertility, and it was 100% for SNVs/indels, CFTR IVS8-5T variants, sex chromosome aneuploidies, and copy number variants (CNVs) and > 93% for Y chromosome microdeletions. Cost analysis shows potential savings when comparing this single NGS assay with the standard approach, which includes multiple assays. A single, comprehensive, NGS panel can simplify the ordering process for healthcare providers, reduce turnaround time, and lower the overall cost of testing for genetic assessment of infertility in females and males, while maintaining accuracy.

  4. Bioimaging of metals in brain tissue by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and metallomics.

    PubMed

    Becker, J Sabine; Matusch, Andreas; Palm, Christoph; Salber, Dagmar; Morton, Kathryn A; Becker, J Susanne

    2010-02-01

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been developed and established as an emerging technique in the generation of quantitative images of metal distributions in thin tissue sections of brain samples (such as human, rat and mouse brain), with applications in research related to neurodegenerative disorders. A new analytical protocol is described which includes sample preparation by cryo-cutting of thin tissue sections and matrix-matched laboratory standards, mass spectrometric measurements, data acquisition, and quantitative analysis. Specific examples of the bioimaging of metal distributions in normal rodent brains are provided. Differences to the normal were assessed in a Parkinson's disease and a stroke brain model. Furthermore, changes during normal aging were studied. Powerful analytical techniques are also required for the determination and characterization of metal-containing proteins within a large pool of proteins, e.g., after denaturing or non-denaturing electrophoretic separation of proteins in one-dimensional and two-dimensional gels. LA-ICP-MS can be employed to detect metalloproteins in protein bands or spots separated after gel electrophoresis. MALDI-MS can then be used to identify specific metal-containing proteins in these bands or spots. The combination of these techniques is described in the second section.

  5. Light attenuation versus evolved carbon (AVEC) - A new way to look at elemental and organic carbon analysis

    NASA Astrophysics Data System (ADS)

    Nicolosi, E. M. G.; Quincey, P.; Font, A.; Fuller, G. W.

    2018-02-01

    The Attenuation Versus Evolved Carbon (AVEC) plot is a new way to represent thermal-optical organic carbon/elemental carbon (OC/EC) analysis data. The accumulated carbon concentration is plotted against the attenuation (ln (I0/I)). Unlike the thermogram, it provides information about the sample properties rather than the instantaneous instrument sensor status. The plot can be used to refine the determination of OC and EC split point, either from consideration of laser instability or transit time within the instrument; to investigate the optical properties of the particles; and to spot the early evolution of pyrolysed carbon (PC) and/or EC during the inert phase. 168 samples from three sites were studied. The gradient of the AVEC plot curve in the oxygenated phase provides information about the mass absorption cross section (σ) of the particles leaving the filter. The σ of the PC generated in the higher temperature Quartz protocol was greater than the PC generated in the lower temperature EUSAAR_2 protocol. Also, in both cases the PC evolved at a lower temperature in the oxygenated phase than the native EC. To minimise the shadowing effect, σ was also measured for the particles leaving the filter at the end of the analysis. These σ values, which are expected to be a combination of inherent σ together with fixed instrumental factors, were consistent between the different sites (45 ± 10 m2 g-1 in rural samples, 42 ± 8 m2 g-1 in urban samples and 35 ± 14 m2 g-1 in roadside samples). The AVEC plot can be generated from the data routinely produced by the analytical instrument using the R-code supplied in the supplementary material.

  6. Standardization and performance evaluation of "modified" and "ultrasensitive" versions of the Abbott RealTime HIV-1 assay, adapted to quantify minimal residual viremia.

    PubMed

    Amendola, Alessandra; Bloisi, Maria; Marsella, Patrizia; Sabatini, Rosella; Bibbò, Angela; Angeletti, Claudio; Capobianchi, Maria Rosaria

    2011-09-01

    Numerous studies investigating clinical significance of HIV-1 minimal residual viremia (MRV) suggest potential utility of assays more sensitive than those routinely used to monitor viral suppression. However currently available methods, based on different technologies, show great variation in detection limit and input plasma volume, and generally suffer from lack of standardization. In order to establish new tools suitable for routine quantification of minimal residual viremia in patients under virological suppression, some modifications were introduced into standard procedure of the Abbott RealTime HIV-1 assay leading to a "modified" and an "ultrasensitive" protocols. The following modifications were introduced: calibration curve extended towards low HIV-1 RNA concentration; 4 fold increased sample volume by concentrating starting material; reduced volume of internal control; adoption of "open-mode" software for quantification. Analytical performances were evaluated using the HIV-1 RNA Working Reagent 1 for NAT assays (NIBSC). Both tests were applied to clinical samples from virologically suppressed patients. The "modified" and the "ultrasensitive" configurations of the assay reached a limit of detection of 18.8 (95% CI: 11.1-51.0 cp/mL) and 4.8 cp/mL (95% CI: 2.6-9.1 cp/mL), respectively, with high precision and accuracy. In clinical samples from virologically suppressed patients, "modified" and "ultrasensitive" protocols allowed to detect and quantify HIV RNA in 12.7% and 46.6%, respectively, of samples resulted "not-detectable", and in 70.0% and 69.5%, respectively, of samples "detected <40 cp/mL" in the standard assay. The "modified" and "ultrasensitive" assays are precise and accurate, and easily adoptable in routine diagnostic laboratories for measuring MRV. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Organic and Isotope Measurement Protocols under Development for the 2009 Mars Science Laboratory

    NASA Technical Reports Server (NTRS)

    Mahaffy, Paul R.; Atreya, Sushil K.

    2006-01-01

    The Mars Science Laboratory (MSL) is under development by NASA with several international partners for launch in 2009. MSL is designed to quantitatively explore a local region on Mars as a potential habitat for present or past life (http://mars.jpl.nasa.gov/msl). The goals of MSL are to (1) assess the past or present biological potential of the target environment, (2) to characterize its geology and geochemistry, (3) to study planetary processes that influence habitability, and (4) to characterize the surface radiation. The last substantial search for organic molecules on the surface of Mars was with the Viking Landers in 1976 [Biemann, et al., 19771. In that mission, no organics were detected in near surface fines and presently a more comprehensive search is required to understand the potential of that planet to support life. While the Mars Exploration Rovers are able to identify mineralogical signatures of aqueous alteration, they are not equipped to search for organics. The planned capabilities of the MSL rover payload will enable a search for a wide range of organic molecules in both solid samples of rocks and fines and atmospheric samples. MSL will also provide a determination of definitive mineralogy of the solid samples and precision isotope measurements of several volatile elements. Contact and remote surface and subsurface survey tools will establish context for Analytical Laboratory measurements and will facilitate sample selection. The Sample Analysis at Mars (SAM) suite of MSL addresses several of the mission's core measurement goals. SAM includes a gas chromatograph, a mass spectrometer, and a tunable laser spectrometer. We will describe the range of measurement protocols under development and test for SAM and the relationship of our planned measurements to outstanding issues of martian habitability.

  8. Protocols for the measurement of the F2-isoprostane, 15(S)-8-iso-prostaglandin F2α, in biological samples by GC-MS or GC-MS/MS coupled with immunoaffinity column chromatography.

    PubMed

    Tsikas, Dimitrios; Suchy, Maria-Theresia

    2016-04-15

    Arachidonic acid, the origin of the eicosanoids family, occurs in biological samples as free acid and as ester in lipids. Free arachidonic acid is oxidized to numerous metabolites by means of enzymes including cyclooxygenase (COX). Arachidonic acid esterified to lipids is attacked by reactive oxygen species (ROS) to generate numerous oxidized arachidonic acid derivatives. Generally, it is assumed that ROS-derived arachidonic acid derivatives are distinct from those generated by enzymes such as COX. Therefore, ROS-generated eicosanoids are considered specific biomarkers of oxidative stress. However, there are serious doubts concerning a strict distinction between the enzyme-derived eicosanoids and the ROS-derived iso-eicosanoids. Prominent examples are prostaglandin F2α (PGF2α) and 15(S)-8-iso-prostaglandin F2α (15(S)-8-iso-PGF2α) which have been originally considered to exclusively derive from COX and ROS, respectively. There is convincing evidence that both COX and ROS can oxidize arachidonic acid to PGF2α and 15(S)-8-iso-PGF2α. Thus, many results previously reported for 15(S)-8-iso-PGF2α as exclusive ROS-dependent reaction product, and consequently as a specific biomarker of oxidative stress, require a careful re-examination which should also consider the analytical methods used to measure 15(S)-8-iso-PGF2α. This prominent but certainly not the only example underlines more than ever the importance of the analytical chemistry in basic and clinical research areas of oxidative stress. In the present work, we report analytical protocols for the reliable quantitative determination of 15(S)-8-iso-PGF2α in human biological samples including plasma and urine by mass spectrometry coupled to gas chromatography (GC-MS, GC-MS/MS) after specific isolation of endogenous 15(S)-8-iso-PGF2α and the externally added internal standard [3,3',4,4'-(2)H4]-15(S)-8-iso-PGF2α by immunoaffinity column chromatography (IAC). 15(S)-8-iso-PGF2α esterified to plasma lipids is hydrolysed by KOH. 15(S)-8-iso-PGF2α and [3,3',4,4'-(2)H4]-15(S)-8-iso-PGF2α are analyzed as pentafluorobenzyl ester trimethylsilyl ether derivatives in the electron-capture negative-ion chemical ionization mode. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Seabird tissue archival and monitoring project: Egg collections and analytical results 1999-2002

    USGS Publications Warehouse

    Vander Pol, Stacy S.; Christopher, Steven J.; Roseneau, David G.; Becker, Paul R.; Day, Russel D.; Kucklick, John R.; Pugh, Rebecca S.; Simac, Kristin S.; Weston-York, Geoff

    2003-01-01

    In 1998, the U.S. Geological Survey Biological Resources Division (USGS-BRD), the U.S. Fish and Wildlife Service (USFWS) Alaska Maritime National Wildlife Refuge (AMNWR), and the National Institute of Standards and Technology (NIST) began the Seabird Tissue Archival and Monitoring Project (STAMP) to collect and cryogenically bank tissues from seabirds in Alaska for future retrospective analysis of anthropogenic contaminants. The approach of STAMP was similar to that of the Alaska Marine Mammal Tissue Archival Project (AMMTAP). AMMTAP was started in 1987 by NIST and the National Oceanic and Atmospheric Administration (NOAA) as part of the Outer Continental Shelf Environmental Assessment Program sponsored by the Minerals Management Service. Presently sponsored by the USGS-BRD, AMMTAP continues its work as part of a larger national program, the Marine Mammal Health and Stranding Response Program. AMMTAP developed carefully designed sampling and specimen banking protocols. Since 1987, AMMTAP has collected tissues from marine mammals taken in Alaska Native subsistence hunts and has cryogenically banked these tissues at the NIST National Biomonitoring Specimen Bank (NBSB). Through its own analytical work and working in partnership with other researchers both within and outside Alaska, AMMTAP has helped to develop a substantial database on contaminants in Alaska marine mammals. In contrast, data and information is limited on contaminants in Alaska seabirds, which are similar to marine mammals in that they feed near the top of the food chain and have the potential for accumulating anthropogenic contaminants. During its early planning stages, STAMP managers identified the seabird egg as the first tissue of choice for study by the project. There is a relatively long history of using bird eggs for environmental monitoring and for investigating the health status of bird populations. Since 1998, protocols for collecting and processing eggs, and cryogenically banking egg samples have been developed by STAMP (see York et al. 2001). Eggs are being collected on an annual basis for several species at nesting colonies throughout Alaska. Aliquots of these egg samples are being analyzed on a regular basis for persistent organic pollutants and mercury. Results of this work have been published in scientific journals (Christopher et al. 2002) and in conference proceedings (Kucklick et al. 2002; Vander Pol et al. 2002a, 2002b). The intent of this report is to provide an up-to-date description of STAMP. The report contains the most recent egg collection inventory, analytical data, preliminary interpretations based on these data, and a discussion of possible future directions of the project.

  10. Standardization of Nanoparticle Characterization: Methods for Testing Properties, Stability, and Functionality of Edible Nanoparticles.

    PubMed

    McClements, Jake; McClements, David Julian

    2016-06-10

    There has been a rapid increase in the fabrication of various kinds of edible nanoparticles for oral delivery of bioactive agents, such as those constructed from proteins, carbohydrates, lipids, and/or minerals. It is currently difficult to compare the relative advantages and disadvantages of different kinds of nanoparticle-based delivery systems because researchers use different analytical instruments and protocols to characterize them. In this paper, we briefly review the various analytical methods available for characterizing the properties of edible nanoparticles, such as composition, morphology, size, charge, physical state, and stability. This information is then used to propose a number of standardized protocols for characterizing nanoparticle properties, for evaluating their stability to environmental stresses, and for predicting their biological fate. Implementation of these protocols would facilitate comparison of the performance of nanoparticles under standardized conditions, which would facilitate the rational selection of nanoparticle-based delivery systems for different applications in the food, health care, and pharmaceutical industries.

  11. Predicting thermal history a-priori for magnetic nanoparticle hyperthermia of internal carcinoma

    NASA Astrophysics Data System (ADS)

    Dhar, Purbarun; Sirisha Maganti, Lakshmi

    2017-08-01

    This article proposes a simplistic and realistic method where a direct analytical expression can be derived for the temperature field within a tumour during magnetic nanoparticle hyperthermia. The approximated analytical expression for thermal history within the tumour is derived based on the lumped capacitance approach and considers all therapy protocols and parameters. The present method is simplistic and provides an easy framework for estimating hyperthermia protocol parameters promptly. The model has been validated with respect to several experimental reports on animal models such as mice/rabbit/hamster and human clinical trials. It has been observed that the model is able to accurately estimate the thermal history within the carcinoma during the hyperthermia therapy. The present approach may find implications in a-priori estimation of the thermal history in internal tumours for optimizing magnetic hyperthermia treatment protocols with respect to the ablation time, tumour size, magnetic drug concentration, field strength, field frequency, nanoparticle material and size, tumour location, and so on.

  12. Compliance program data management system for The Idaho National Engineering Laboratory/Environmental Protection Agency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hertzler, C.L.; Poloski, J.P.; Bates, R.A.

    1988-01-01

    The Compliance Program Data Management System (DMS) developed at the Idaho National Engineering Laboratory (INEL) validates and maintains the integrity of data collected to support the Consent Order and Compliance Agreement (COCA) between the INEL and the Environmental Protection Agency (EPA). The system uses dBase III Plus programs and dBase III Plus in an interactive mode to enter, store, validate, manage, and retrieve analytical information provided on EPA Contract Laboratory Program (CLP) forms and CLP forms modified to accommodate 40 CFR 264 Appendix IX constituent analyses. Data analysis and presentation is performed utilizing SAS, a statistical analysis software program. Archivingmore » of data and results is performed at appropriate stages of data management. The DMS is useful for sampling and analysis programs where adherence to EPA CLP protocol, along with maintenance and retrieval of waste site investigation sampling results is desired or requested. 3 refs.« less

  13. Tools for phospho- and glycoproteomics of plasma membranes.

    PubMed

    Wiśniewski, Jacek R

    2011-07-01

    Analysis of plasma membrane proteins and their posttranslational modifications is considered as important for identification of disease markers and targets for drug treatment. Due to their insolubility in water, studying of plasma membrane proteins using mass spectrometry has been difficult for a long time. Recent technological developments in sample preparation together with important improvements in mass spectrometric analysis have facilitated analysis of these proteins and their posttranslational modifications. Now, large scale proteomic analyses allow identification of thousands of membrane proteins from minute amounts of sample. Optimized protocols for affinity enrichment of phosphorylated and glycosylated peptides have set new dimensions in the depth of characterization of these posttranslational modifications of plasma membrane proteins. Here, I summarize recent advances in proteomic technology for the characterization of the cell surface proteins and their modifications. In the focus are approaches allowing large scale mapping rather than analytical methods suitable for studying individual proteins or non-complex mixtures.

  14. Evaluation of storage and filtration protocols for alpine/subalpine lake water quality samples

    Treesearch

    John L. Korfmacher; Robert C. Musselman

    2007-01-01

    Many government agencies and other organizations sample natural alpine and subalpine surface waters using varying protocols for sample storage and filtration. Simplification of protocols would be beneficial if it could be shown that sample quality is unaffected. In this study, samples collected from low ionic strength waters in alpine and subalpine lake inlets...

  15. 7 CFR 301.92-11 - Inspection and sampling protocols.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Inspection and sampling protocols. 301.92-11 Section... Inspection and sampling protocols. Type(s) of plants in the nursery Type(s) of plants shipped interstate... interstate. (1) Annual inspection, sampling, and testing—(i) Inspection. The nursery must be inspected...

  16. 7 CFR 301.92-11 - Inspection and sampling protocols.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 5 2011-01-01 2011-01-01 false Inspection and sampling protocols. 301.92-11 Section... Inspection and sampling protocols. Type(s) of plants in the nursery Type(s) of plants shipped interstate... interstate. (1) Annual inspection, sampling, and testing—(i) Inspection. The nursery must be inspected...

  17. A Model for Developing Clinical Analytics Capacity: Closing the Loops on Outcomes to Optimize Quality.

    PubMed

    Eggert, Corinne; Moselle, Kenneth; Protti, Denis; Sanders, Dale

    2017-01-01

    Closed Loop Analytics© is receiving growing interest in healthcare as a term referring to information technology, local data and clinical analytics working together to generate evidence for improvement. The Closed Loop Analytics model consists of three loops corresponding to the decision-making levels of an organization and the associated data within each loop - Patients, Protocols, and Populations. The authors propose that each of these levels should utilize the same ecosystem of electronic health record (EHR) and enterprise data warehouse (EDW) enabled data, in a closed-loop fashion, with that data being repackaged and delivered to suit the analytic and decision support needs of each level, in support of better outcomes.

  18. Conventional and accelerated-solvent extractions of green tea (camellia sinensis) for metabolomics-based chemometrics.

    PubMed

    Kellogg, Joshua J; Wallace, Emily D; Graf, Tyler N; Oberlies, Nicholas H; Cech, Nadja B

    2017-10-25

    Metabolomics has emerged as an important analytical technique for multiple applications. The value of information obtained from metabolomics analysis depends on the degree to which the entire metabolome is present and the reliability of sample treatment to ensure reproducibility across the study. The purpose of this study was to compare methods of preparing complex botanical extract samples prior to metabolomics profiling. Two extraction methodologies, accelerated solvent extraction and a conventional solvent maceration, were compared using commercial green tea [Camellia sinensis (L.) Kuntze (Theaceae)] products as a test case. The accelerated solvent protocol was first evaluated to ascertain critical factors influencing extraction using a D-optimal experimental design study. The accelerated solvent and conventional extraction methods yielded similar metabolite profiles for the green tea samples studied. The accelerated solvent extraction yielded higher total amounts of extracted catechins, was more reproducible, and required less active bench time to prepare the samples. This study demonstrates the effectiveness of accelerated solvent as an efficient methodology for metabolomics studies. Copyright © 2017. Published by Elsevier B.V.

  19. Measurement of stable isotopic enrichment and concentration of long-chain fatty acyl-carnitines in tissue by HPLC-MS.

    PubMed

    Sun, Dayong; Cree, Melanie G; Zhang, Xiao-Jun; Bøersheim, Elisabet; Wolfe, Robert R

    2006-02-01

    We have developed a new method for the simultaneous measurements of stable isotopic tracer enrichments and concentrations of individual long-chain fatty acyl-carnitines in muscle tissue using ion-pairing high-performance liquid chromatography-electrospray ionization quadrupole mass spectrometry in the selected ion monitoring (SIM) mode. Long-chain fatty acyl-carnitines were extracted from frozen muscle tissue samples by acetonitrile/methanol. Baseline separation was achieved by reverse-phase HPLC in the presence of the volatile ion-pairing reagent heptafluorobutyric acid. The SIM capability of a single quadrupole mass analyzer allows further separation of the ions of interest from the sample matrixes, providing very clean total and selected ion chromatograms that can be used to calculate the stable isotopic tracer enrichment and concentration of long-chain fatty acyl-carnitines in a single analysis. The combination of these two separation techniques greatly simplifies the sample preparation procedure and increases the detection sensitivity. Applying this protocol to biological muscle samples proves it to be a very sensitive, accurate, and precise analytical tool.

  20. Spectrometric Analysis for Pulse Jet Mixer Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ZEIGLER, KRISTINE

    2004-07-12

    The Analytical Development Section (ADS) was tasked with providing support for a Hanford River Protection Program-Waste Treatment Program (RPP-WTP) project test involving absorption analysis for non-Newtonian pulse jet mixer testing for small scale (PJM) and prototype (CRV) tanks with sparging. Tanks filled with clay were mixed with various amounts of powdered dye as a tracer. The objective of the entire project was to determine the best mixing protocol (nozzle velocity, number of spargers used, total air flow, etc.) by determining the percent mixed volume through the use of an ultraviolet-visible (UV-Vis) spectrometer. The dye concentration within the sample could bemore » correlated to the volume fraction mixed in the tank. Samples were received in vials, a series of dilutions were generated from the clay, allowed to equilibrate, then centrifuged and siphoned for the supernate liquid to analyze by absorption spectroscopy. Equilibration of the samples and thorough mixing of the samples were a continuous issue with dilution curves being difficult to obtain. Despite these technical issues, useful data was obtained for evaluation of various mix conditions.« less

  1. Detection of sorbitol-negative and sorbitol-positive Shiga toxin-producing Escherichia coli, Listeria monocytogenes, Campylobacter jejuni, and Salmonella spp. in dairy farm environmental samples.

    PubMed

    Murinda, S E; Nguyen, L T; Nam, H M; Almeida, R A; Headrick, S J; Oliver, S P

    2004-01-01

    Six visits were conducted to four dairy farms to collect swab, liquid, and solid dairy farm environmental samples (165 to 180/farm; 15 sample types). The objective of the study was to determine on-farm sources of Campylobacter jejuni, Salmonella spp., Listeria monocytogenes, and Shiga toxin-producing Escherichia coli (STEC), which might serve as reservoirs for transmission of pathogens. Samples were analyzed using mostly U.S. Food and Drug Administration's Bacteriological Analytical Manual protocols; however, Salmonella spp., L. monocytogenes and STEC were co-enriched in universal pre-enrichment broth. Campylobacter jejuni were enriched in Bolton broth containing Bolton broth supplement. Pathogens were isolated on agar media, typed biochemically, and confirmed using multiplex polymerase chain reaction protocols. Campylobacter jejuni, Salmonella spp., L. monocytogenes, Sorbitol-negative (SN)-STEC O157:H7, and sorbitol-positive (SP)-STEC, respectively, were isolated from 5.06%, 3.76%, 6.51%, 0.72%, and 17.3% of samples evaluated. Whereas other pathogens were isolated from all four farms, SN-STEC O157:H7 were isolated from only two farms. Diverse serotypes of SP-STEC including O157:H7, O26:H11, O111, and O103 were isolated. None of the five pathogen groups studied were isolated from bulk tank milk (BTM). Most pathogens (44.2%) were isolated directly from fecal samples. Bovine fecal samples, lagoon water, bedding, bird droppings, and rat intestinal contents constituted areas of major concern on dairy farms. Although in-line milk filters from two farms tested positive for Salmonella or L. monocytogenes, none of the pathogens were detected in the corresponding BTM samples. Good manure management practices, including control of feral animals, are critical in assuring dairy farm hygiene. Identification of on-farm pathogen reservoirs could aid with implementation of farm-specific pathogen reduction programs.

  2. Simultaneous hair testing for opiates, cocaine, and metabolites by GC-MS: a survey of applicants for driving licenses with a history of drug use.

    PubMed

    Montagna, M; Stramesi, C; Vignali, C; Groppi, A; Polettini, A

    2000-01-10

    A sensitive GC-MS method for the simultaneous determination of opiates, cocaine, and metabolites in hair at a cut-off level of 0.1 ng/mg was adopted to assess past exposure to these drugs in applicants for driving licenses with a history of drug use. The sampling protocol consisted of collection of one hair (sample A, 5-cm length) and one urine sample. When hair and urine (EMIT Syva, cut-off levels: 0.3 mg/l for opiates, 0.15 mg/l for cocaine, GC-MS confirmation of positives) were both positive or negative the protocol was concluded. In the other cases, the assessment of 'current exposure' to drugs was carried out, in order to avoid seriated random urinalysis, by collecting a second hair sample (sample B) 6 weeks later and analysing the proximal 1-cm segment. Out of the 214 'A' hair samples analyzed, 14 (6.5%) tested positive for morphine and/or 6-acetylmorphine (6AM), and 26 (12%) for cocaine and/or benzoylecgonine (BE), whereas none of the samples tested positive for both drugs. Levels between 0.1 and 1 ng/mg of the single analytes were found in eight out of the 14 morphine-6AM positives (57%) and in 18 out of the 26 cocaine-BE positives (69%). The time course of positive cases showed a progressive decrease of morphine-6AM positives and a corresponding increase of cocaine-BE positives within the study period September 1995-February 1999. No cases with positive urine and negative hair were observed. Among the 40 positive cases, seven (four and three for opiates and cocaine, respectively) were found to be 'currently exposed to drug', four by urinalysis (three and one) and three by analysis of the hair sample B (1 and 2).

  3. Evaluation of FUS-2000 urine analyzer: analytical properties and particle recognition.

    PubMed

    Beňovská, Miroslava; Wiewiorka, Ondřej; Pinkavová, Jana

    This study evaluates the performance of microscopic part of a hybrid analyzer FUS-2000 (Dirui Industrial Co., Changchun, China), its analytical properties and particle recognition. The evaluation of trueness, repeatability, detection limit, carry-over, linearity range and analytical stability was performed according to Dirui protocol guidelines designed by Dirui Company to guarantee the quality of the instrument. Trueness for low, medium and high-value concentrations was calculated with bias of 15.5, 4.7 and -6.6%, respectively. Detection limit of 5 Ery/μl was confirmed. Coefficient of variation of 11.0, 5.2 and 3.8% was measured for within-run repeatability of low, medium and high concentration. Between-run repeatability for daily quality control had coefficient of variation of 3.0%. Carry-over did not exceed 0.05%. Linearity was confirmed for range of 0-16,000 particles/μl (R 2  = 0.9997). The analytical stability had coefficient of variation of 4.3%. Out of 1258 analyzed urine samples, 362 positive were subjected to light microscopy urine sediment analysis and compared to the analyzer results. Cohen's kappa coefficients were calculated to express the concordance. Squared kappa coefficient was 0.927 (red blood cells), 0.888 (white blood cells), 0.908 (squamous epithelia), 0.634 (transitional epithelia), 0.628 (hyaline casts), 0.843 (granular casts) and 0.623 (bacteria). Single kappa coefficients were 0.885 (yeasts) and 0.756 (crystals), respectively. Aforementioned results show good analytical performance of the analyzer and tight agreement with light microscopy of urine sediment.

  4. A comparison of single and multiple stressor protocols to assess acute stress in a coastal shark species, Rhizoprionodon terraenovae.

    PubMed

    Hoffmayer, Eric R; Hendon, Jill M; Parsons, Glenn R; Driggers, William B; Campbell, Matthew D

    2015-10-01

    Elasmobranch stress responses are traditionally measured in the field by either singly or serially sampling an animal after a physiologically stressful event. Although capture and handling techniques are effective at inducing a stress response, differences in protocols could affect the degree of stress experienced by an individual, making meaningful comparisons between the protocols difficult, if not impossible. This study acutely stressed Atlantic sharpnose sharks, Rhizoprionodon terraenovae, by standardized capture (rod and reel) and handling methods and implemented either a single or serial blood sampling protocol to monitor four indicators of the secondary stress response. Single-sampled sharks were hooked and allowed to swim around the boat until retrieved for a blood sample at either 0, 15, 30, 45, or 60 min post-hooking. Serially sampled sharks were retrieved, phlebotomized, released while still hooked, and subsequently resampled at 15, 30, 45, and 60 min intervals post-hooking. Blood was analyzed for hematocrit, and plasma glucose, lactate, and osmolality levels. Although both single and serial sampling protocols resulted in an increase in glucose, no significant difference in glucose level was found between protocols. Serially sampled sharks exhibited cumulatively heightened levels for lactate and osmolality at all time intervals when compared to single-sampled animals at the same time. Maximal concentration differences of 217.5, 9.8, and 41.6 % were reported for lactate, osmolality, and glucose levels, respectively. Hematocrit increased significantly over time for the single sampling protocol but did not change significantly during the serial sampling protocol. The differences in resultant blood chemistry levels between implemented stress protocols and durations are significant and need to be considered when assessing stress in elasmobranchs.

  5. Efficient Online Optimized Quantum Control for Adiabatic Quantum Computation

    NASA Astrophysics Data System (ADS)

    Quiroz, Gregory

    Adiabatic quantum computation (AQC) relies on controlled adiabatic evolution to implement a quantum algorithm. While control evolution can take many forms, properly designed time-optimal control has been shown to be particularly advantageous for AQC. Grover's search algorithm is one such example where analytically-derived time-optimal control leads to improved scaling of the minimum energy gap between the ground state and first excited state and thus, the well-known quadratic quantum speedup. Analytical extensions beyond Grover's search algorithm present a daunting task that requires potentially intractable calculations of energy gaps and a significant degree of model certainty. Here, an in situ quantum control protocol is developed for AQC. The approach is shown to yield controls that approach the analytically-derived time-optimal controls for Grover's search algorithm. In addition, the protocol's convergence rate as a function of iteration number is shown to be essentially independent of system size. Thus, the approach is potentially scalable to many-qubit systems.

  6. Development of the Basis for an Analytical Protocol for Feeds and Products of Bio-oil Hydrotreatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oasmaa, Anja; Kuoppala, Eeva; Elliott, Douglas C.

    2012-04-02

    Methods for easily following the main changes in the composition, stability, and acidity of bio-oil in hydrotreatment are presented. The correlation to more conventional methods is provided. Depending on the final use the upgrading requirement is different. This will create challenges also for the analytical protocol. Polar pyrolysis liquids and their products can be divided into five main groups with solvent fractionation the change in which is easy to follow. This method has over ten years been successfully used for comparison of fast pyrolysis bio-oil quality, and the changes during handling, and storage, provides the basis of the analytical protocolmore » presented in this paper. The method has most recently been used also for characterisation of bio-oil hydrotreatment products. Discussion on the use of gas chromatographic and spectroscopic methods is provided. In addition, fuel oil analyses suitable for fast pyrolysis bio-oils and hydrotreatment products are discussed.« less

  7. A novel ion-exclusion chromatography-mass spectrometry method to measure concentrations and cycling rates of carbohydrates and amino sugars in freshwaters.

    PubMed

    Horňák, Karel; Pernthaler, Jakob

    2014-10-24

    The concentrations of free neutral carbohydrates and amino sugars were determined in freshwater samples of distinct matrix complexity, including meso-, eu- and dystrophic lakes and ponds, using high-performance ion-exclusion chromatography (HPIEC) coupled to mass spectrometry (MS). In contrast to other methods, our approach allowed the quantification of free neutral carbohydrates and amino sugars at low nM concentrations without derivatization, de-salting or pre-concentration. New sample preparation procedures were applied prior to injection employing syringe and hollow fiber filtration. Analytes were separated on a strong cation exchange resin under 100% aqueous conditions using 0.1% formic acid as a mobile phase. To minimize background noise in MS, analytes were detected in a multiple reaction monitoring scan mode with double ion filtering. Detection limits of carbohydrates and amino sugars ranged between 0.2 and 2nM at a signal-to-noise ratio >5. Error ranged between 1 and 12% at 0.5-500nM levels. Using a stable isotope dilution approach, both the utilization and recycling of glucose in Lake Zurich was observed. In contrast, N-acetyl-glucosamine was equally rapidly consumed but there was no visible de novo production. The simple and rapid sample preparation makes our protocol suitable for routine analyses of organic compounds in freshwater samples. Application of stable isotope tracers along with accurate measures of carbohydrate and amino sugar concentrations enables novel insights into the compound in situ dynamics. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. DART-MS: A New Analytical Technique for Forensic Paint Analysis.

    PubMed

    Marić, Mark; Marano, James; Cody, Robert B; Bridge, Candice

    2018-06-05

    Automotive paint evidence is one of the most significant forms of evidence obtained in automotive-related incidents. Therefore, the analysis of automotive paint evidence is imperative in forensic casework. Most analytical schemes for automotive paint characterization involve optical microscopy, followed by infrared spectroscopy and pyrolysis-gas chromatography mass spectrometry ( py-GCMS) if required. The main drawback with py-GCMS, aside from its destructive nature, is that this technique is relatively time intensive in comparison to other techniques. Direct analysis in real-time-time-of-flight mass spectrometry (DART-TOFMS) may provide an alternative to py-GCMS, as the rapidity of analysis and minimal sample preparation affords a significant advantage. In this study, automotive clear coats from four vehicles were characterized by DART-TOFMS and a standard py-GCMS protocol. Principal component analysis was utilized to interpret the resultant data and suggested the two techniques provided analogous sample discrimination. Moreover, in some instances DART-TOFMS was able to identify components not observed by py-GCMS and vice versa, which indicates that the two techniques may provide complementary information. Additionally, a thermal desorption/pyrolysis DART-TOFMS methodology was also evaluated to characterize the intact paint chips from the vehicles to ascertain if the linear temperature gradient provided additional discriminatory information. All the paint samples were able to be discriminated based on the distinctive thermal desorption plots afforded from this technique, which may also be utilized for sample discrimination. On the basis of the results, DART-TOFMS may provide an additional tool to the forensic paint examiner.

  9. Determination of adsorbable organic halogens in surface water samples by combustion-microcoulometry versus combustion-ion chromatography titration.

    PubMed

    Kinani, Aziz; Sa Lhi, Hacène; Bouchonnet, Stéphane; Kinani, Said

    2018-03-02

    Adsorbable Organic Halogen (AOX) is an analytical parameter of considerable interest since it allows to evaluate the amount of organohalogen disinfection by-products (OXBPs) present in a water sample. Halogen speciation of AOX into adsorbable organic chlorine, bromine and iodine, respectively AOCl, AOBr and AOI, is extremely important since it has been shown that iodinated and brominated organic by-products tend to be more toxic than their chlorinated analogues. Chemical speciation of AOX can be performed by combustion-ion chromatography (C-IC). In the present work, the effectiveness of the nitrate wash according to ISO 9562 standard method protocol to eliminate halide ions interferences was firstly examined. False positive AOX values were observed when chloride concentration exceeded 100 ppm. The improvements made to the washing protocol have eliminated chloride interference for concentrations up to 1000 ppm. A C-IC method for chemical speciation of AOX into AOCl, AOBr, and AOI has been developed and validated. The most important analytical parameters were investigated. The following optimal conditions were established: an aqueous solution containing 2.4 mM sodium bicarbonate/2.0 mM sodium carbonate, and 2% acetone (v/v) as mobile phase, 2 mL of aqueous sodium thiosulfate (500 ppm) as absorption solution, 0.2 mL min -1 as water inlet flow rate for hydropyrolysis, and 10 min as post-combustion time. The method was validated according to NF T90-210 standard method. Calibration curves fitted through a quadratic equation show coefficients of determination (r 2 ) greater than 0.9998, and RSD less than 5%. The LOQs were 0.9, 4.3, and 5.7 μg L -1 Cl for AOCl, AOBr, and AOI, respectively. The accuracy, in terms of relative error, was within a ± 10% interval. The applicability of the validated method was demonstrated by the analysis of twenty four water samples from three rivers in France. The measurements reveals AOX amounts above 10 μg L -1 Cl in all untreated samples, suggesting the presence of organohalogen compounds in the sampled rivers. On weight concentration basis, AOCl accounted for 77-100% of AOX in the treated water samples. A good agreement between the conventional AOX method and the developed C-IC method was found. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. A Draft Test Protocol for Detecting Possible Biohazards in Martian Samples Returned to Earth

    NASA Technical Reports Server (NTRS)

    Rummel, John D. (Editor); Race, Margaret S.; DeVincenzi, Donald L.; Schad, P. Jackson; Stabekis, Pericles D.; Viso, Michel; Acevedo, Sara E.

    2002-01-01

    This document presents the first complete draft of a protocol for detecting possible biohazards in Mars samples returned to Earth: it is the final product of the Mars Sample Handling Protocol Workshop Series. convened in 2000-2001 by NASA's Planetary Protection Officer. The goal of the five-workshop Series vas to develop a comprehensive protocol by which returned martian sample materials could be assessed k r the presence of any biological hazard(s) while safeguarding the purity of the samples from possible terrestrial contamination.

  11. Copper and tin isotopic analysis of ancient bronzes for archaeological investigation: development and validation of a suitable analytical methodology.

    PubMed

    Balliana, Eleonora; Aramendía, Maite; Resano, Martin; Barbante, Carlo; Vanhaecke, Frank

    2013-03-01

    Although in many cases Pb isotopic analysis can be relied on for provenance determination of ancient bronzes, sometimes the use of "non-traditional" isotopic systems, such as those of Cu and Sn, is required. The work reported on in this paper aimed at revising the methodology for Cu and Sn isotope ratio measurements in archaeological bronzes via optimization of the analytical procedures in terms of sample pre-treatment, measurement protocol, precision, and analytical uncertainty. For Cu isotopic analysis, both Zn and Ni were investigated for their merit as internal standard (IS) relied on for mass bias correction. The use of Ni as IS seems to be the most robust approach as Ni is less prone to contamination, has a lower abundance in bronzes and an ionization potential similar to that of Cu, and provides slightly better reproducibility values when applied to NIST SRM 976 Cu isotopic reference material. The possibility of carrying out direct isotopic analysis without prior Cu isolation (with AG-MP-1 anion exchange resin) was investigated by analysis of CRM IARM 91D bronze reference material, synthetic solutions, and archaeological bronzes. Both procedures (Cu isolation/no Cu isolation) provide similar δ (65)Cu results with similar uncertainty budgets in all cases (±0.02-0.04 per mil in delta units, k = 2, n = 4). Direct isotopic analysis of Cu therefore seems feasible, without evidence of spectral interference or matrix-induced effect on the extent of mass bias. For Sn, a separation protocol relying on TRU-Spec anion exchange resin was optimized, providing a recovery close to 100 % without on-column fractionation. Cu was recovered quantitatively together with the bronze matrix with this isolation protocol. Isotopic analysis of this Cu fraction provides δ (65)Cu results similar to those obtained upon isolation using AG-MP-1 resin. This means that Cu and Sn isotopic analysis of bronze alloys can therefore be carried out after a single chromatographic separation using TRU-Spec resin. Tin isotopic analysis was performed relying on Sb as an internal standard used for mass bias correction. The reproducibility over a period of 1 month (n = 42) for the mass bias-corrected Sn isotope ratios is in the range of 0.06-0.16 per mil (2 s), for all the ratios monitored.

  12. 77 FR 5492 - Magnuson-Stevens Act Provisions; General Provisions for Domestic Fisheries; Application for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-03

    ... assess the performance of an approved sampling protocol and to allow for continued sample collection and... developmental sampling protocol. While this application was being reviewed and was available for public comment, the sampling protocol being tested was adopted into the National Shellfish Sanitation Program by the...

  13. Screening of agrochemicals in foodstuffs using low-temperature plasma (LTP) ambient ionization mass spectrometry.

    PubMed

    Wiley, Joshua S; García-Reyes, Juan F; Harper, Jason D; Charipar, Nicholas A; Ouyang, Zheng; Cooks, R Graham

    2010-05-01

    Low-temperature plasma (LTP) permits direct ambient ionization and mass analysis of samples in their native environment with minimal or no prior preparation. LTP utilizes dielectric barrier discharges (DBDs) to create a low power plasma which is guided by gas flow onto the sample from which analytes are desorbed and ionized. In this study, the potential of LTP-MS for the detection of pesticide residues in food is demonstrated. Thirteen multi-class agricultural chemicals were studied (ametryn, amitraz, atrazine, buprofezin, DEET, diphenylamine, ethoxyquin, imazalil, isofenphos-methyl, isoproturon, malathion, parathion-ethyl and terbuthylazine). To evaluate the potential of the proposed approach, LTP-MS experiments were performed directly on fruit peels as well as on fruit/vegetable extracts. Most of the agrochemicals examined displayed remarkable sensitivity in the positive ion mode, giving limits of detection (LOD) for the direct measurement in the low picogram range. Tandem mass spectrometry (MS/MS) was used to confirm identification of selected pesticides by using for these experiments spiked fruit/vegetable extracts (QuEChERS, a standard sample treatment protocol) at levels as low as 1 pg, absolute, for some of the analytes. Comparisons of the data obtained by direct LTP-MS were made with the slower but more accurate conventional LC-MS/MS procedure. Herbicides spiked in aqueous solutions were detectable at LODs as low as 0.5 microg L(-1) without the need for any sample preparation. The results demonstrate that ambient LTP-MS can be applied for the detection and confirmation of traces of agrochemicals in actual market-purchased produce and in natural water samples. Quantitative analysis was also performed in a few selected cases and displayed a relatively high degree of linearity over four orders of magnitude.

  14. A simple method for the small scale synthesis and solid-phase extraction purification of steroid sulfates.

    PubMed

    Waller, Christopher C; McLeod, Malcolm D

    2014-12-01

    Steroid sulfates are a major class of steroid metabolite that are of growing importance in fields such as anti-doping analysis, the detection of residues in agricultural produce or medicine. Despite this, many steroid sulfate reference materials may have limited or no availability hampering the development of analytical methods. We report simple protocols for the rapid synthesis and purification of steroid sulfates that are suitable for adoption by analytical laboratories. Central to this approach is the use of solid-phase extraction (SPE) for purification, a technique routinely used for sample preparation in analytical laboratories around the world. The sulfate conjugates of sixteen steroid compounds encompassing a wide range of steroid substitution patterns and configurations are prepared, including the previously unreported sulfate conjugates of the designer steroids furazadrol (17β-hydroxyandrostan[2,3-d]isoxazole), isofurazadrol (17β-hydroxyandrostan[3,2-c]isoxazole) and trenazone (17β-hydroxyestra-4,9-dien-3-one). Structural characterization data, together with NMR and mass spectra are reported for all steroid sulfates, often for the first time. The scope of this approach for small scale synthesis is highlighted by the sulfation of 1μg of testosterone (17β-hydroxyandrost-4-en-3-one) as monitored by liquid chromatography-mass spectrometry (LCMS). Copyright © 2014 Elsevier Inc. All rights reserved.

  15. An automated protocol for performance benchmarking a widefield fluorescence microscope.

    PubMed

    Halter, Michael; Bier, Elianna; DeRose, Paul C; Cooksey, Gregory A; Choquette, Steven J; Plant, Anne L; Elliott, John T

    2014-11-01

    Widefield fluorescence microscopy is a highly used tool for visually assessing biological samples and for quantifying cell responses. Despite its widespread use in high content analysis and other imaging applications, few published methods exist for evaluating and benchmarking the analytical performance of a microscope. Easy-to-use benchmarking methods would facilitate the use of fluorescence imaging as a quantitative analytical tool in research applications, and would aid the determination of instrumental method validation for commercial product development applications. We describe and evaluate an automated method to characterize a fluorescence imaging system's performance by benchmarking the detection threshold, saturation, and linear dynamic range to a reference material. The benchmarking procedure is demonstrated using two different materials as the reference material, uranyl-ion-doped glass and Schott 475 GG filter glass. Both are suitable candidate reference materials that are homogeneously fluorescent and highly photostable, and the Schott 475 GG filter glass is currently commercially available. In addition to benchmarking the analytical performance, we also demonstrate that the reference materials provide for accurate day to day intensity calibration. Published 2014 Wiley Periodicals Inc. Published 2014 Wiley Periodicals Inc. This article is a US government work and, as such, is in the public domain in the United States of America.

  16. A core-shell column approach to a comprehensive high-performance liquid chromatography phenolic analysis of Vitis vinifera L. and interspecific hybrid grape juices, wines, and other matrices following either solid phase extraction or direct injection.

    PubMed

    Manns, David C; Mansfield, Anna Katharine

    2012-08-17

    Four high-throughput reverse-phase chromatographic protocols utilizing two different core-shell column chemistries have been developed to analyze the phenolic profiles of complex matrices, specifically targeting juices and wines produced from interspecific hybrid grape cultivars. Following pre-fractionation via solid-phase extraction or direct injection, individual protocols were designed to resolve, identify and quantify specific chemical classes of compounds including non-anthocyanin monomeric phenolics, condensed tannins following acid hydrolysis, and anthocyanins. Detection levels ranging from 1.2 ppb to 27.5 ppb, analyte %RSDs ranging from 0.04 to 0.38, and linear ranges of quantitation approaching five orders of magnitude were achieved using conventional HPLC instrumentation. Using C(18) column chemistry, the non-anthocyanin monomeric protocol effectively separated a set of 16 relevant phenolic compounds comprised flavan-3-ols, hydroxycinnamic acids, and flavonols in under 14 min. The same column was used to develop a 15-min protocol for hydrolyzed condensed tannin analysis. Two anthocyanin protocols are presented, one utilizing the same C(18) column, best suited for anthocyanidin and monoglucoside analysis, the other utilizing a pentafluorophenyl chemistry optimized to effectively separate complex mixtures of coexisting mono- and diglucoside anthocyanins. These protocols and column chemistries have been used initially to explore a wide variety of complex phenolic matrices, including red and white juices and wines produced from Vitis vinifera and interspecific hybrid grape cultivars, juices, teas, and plant extracts. Each protocol displayed robust matrix responses as written, yet are flexible enough to be easily modified to suit specifically tailored analytical requirements. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Determination of benzodiazepines in beverages using green extraction methods and capillary HPLC-UV detection.

    PubMed

    Piergiovanni, Maurizio; Cappiello, Achille; Famiglini, Giorgio; Termopoli, Veronica; Palma, Pierangela

    2018-05-30

    Dispersive liquid-liquid microextraction with and without ultrasound assistance (DLLME, UA-DLLME) and microextraction with packed sorbent (MEPS) methods for the extraction and determination of eight different benzodiazepines (BDZ) (chlordiazepoxide, flurazepam, bromazepam, oxazepam, lorazepam, clobazam, clonazepam, and flunitrazepam) in three commercial non-alcoholic and light alcoholic beverages were optimized and compared. Benzodiazepines are frequently used for their extensive diffusion and strong numbing effect in drug-facilitated crimes (DFC). The tiny small amount of sample required for DLLME and MEPS extraction makes them very suitable for specimens collected at the crime scene of DFCs. Microextraction techniques are of increasing interest thanks to their accordance to green analytical chemistry (GAC) guidelines providing good recovery values. Ultrasound assistance (UA-DLLME) was used to investigate whether this type of energy can improve the recoveries of the analytes. Analyses of the extracts were performed with reverse-phase capillary high-performance liquid chromatography with UV detection (HPLC - UV), thanks to low environmental impact, robustness, diffusion, and affordability. Recovery percentages at three different concentrations in the three beverages were between 14.30% and 103.28% with intraday and interday RSD lower than ±2.78%. The same samples were extracted using a MEPS protocol, and the results were compared with those obtained with DLLME. MEPS gave recoveries between 20.90% and 101.88% for all matrices showing a better performance than DLLME at higher concentrations, though lower recoveries were observed with diluted samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Recommended protocols for sampling macrofungi

    Treesearch

    Gregory M. Mueller; John Paul Schmit; Sabine M. Hubndorf Leif Ryvarden; Thomas E. O' Dell; D. Jean Lodge; Patrick R. Leacock; Milagro Mata; Loengrin Umania; Qiuxin (Florence) Wu; Daniel L. Czederpiltz

    2004-01-01

    This chapter discusses several issues regarding reommended protocols for sampling macrofungi: Opportunistic sampling of macrofungi, sampling conspicuous macrofungi using fixed-size, sampling small Ascomycetes using microplots, and sampling a fixed number of downed logs.

  19. National Sample Assessment Protocols

    ERIC Educational Resources Information Center

    Ministerial Council on Education, Employment, Training and Youth Affairs (NJ1), 2012

    2012-01-01

    These protocols represent a working guide for planning and implementing national sample assessments in connection with the national Key Performance Measures (KPMs). The protocols are intended for agencies involved in planning or conducting national sample assessments and personnel responsible for administering associated tenders or contracts,…

  20. Method for Operating a Sensor to Differentiate Between Analytes in a Sample

    DOEpatents

    Kunt, Tekin; Cavicchi, Richard E; Semancik, Stephen; McAvoy, Thomas J

    1998-07-28

    Disclosed is a method for operating a sensor to differentiate between first and second analytes in a sample. The method comprises the steps of determining a input profile for the sensor which will enhance the difference in the output profiles of the sensor as between the first analyte and the second analyte; determining a first analyte output profile as observed when the input profile is applied to the sensor; determining a second analyte output profile as observed when the temperature profile is applied to the sensor; introducing the sensor to the sample while applying the temperature profile to the sensor, thereby obtaining a sample output profile; and evaluating the sample output profile as against the first and second analyte output profiles to thereby determine which of the analytes is present in the sample.

  1. A new gold standard approach to characterize the transport of Si across cell membranes in animals.

    PubMed

    Garneau, Alexandre P; Marcoux, Andrée-Anne; Frenette-Cotton, Rachelle; Bélanger, Richard; Isenring, Paul

    2018-01-11

    Silicon (Si) is increasingly recognized as an essential trace element in animals, especially since the identification of mammalian Si transport systems and Si responsive genes not long ago. During many years, however, efforts to gain substantial insight into the biological role of this element in animals have achieved partial success due in part to the unavailability of validated protocols to study Si movement across biological membranes. To circumvent such limitations, we have developed a general transport assay in which cellular Si content was determined by automated electrothermal atomic absorption spectrophotometry. We have found this assay to provide great analytic sensitivity with Si detection thresholds of less than 1 µM, that is, below or very close to the concentration range of animal cells. We have also found this assay to provide valid and cost-effective determinations in Si transport studies while requiring workable quantities of samples. The protocol described here should thus become gold standard toward accelerated progress in the field of Si transport. © 2018 Wiley Periodicals, Inc.

  2. A Mobility-Aware QoS Signaling Protocol for Ambient Networks

    NASA Astrophysics Data System (ADS)

    Jeong, Seong-Ho; Lee, Sung-Hyuck; Bang, Jongho

    Mobility-aware quality of service (QoS) signaling is crucial to provide seamless multimedia services in the ambient environment where mobile nodes may move frequently between different wireless access networks. The mobility of an IP-based node in ambient networks affects routing paths, and as a result, can have a significant impact on the operation and state management of QoS signaling protocols. In this paper, we first analyze the impact of mobility on QoS signaling protocols and how the protocols operate in mobility scenarios. We then propose an efficient mobility-aware QoS signaling protocol which can operate adaptively in ambient networks. The key features of the protocol include the fast discovery of a crossover node where the old and new paths converge or diverge due to handover and the localized state management for seamless services. Our analytical and simulation/experimental results show that the proposed/implemented protocol works better than existing protocols in the IP-based mobile environment.

  3. Loch Vale Watershed Project quality assurance report, 1995-1998

    USGS Publications Warehouse

    Allstott, E.J.; Bashkin, Michael A.; Baron, Jill S.

    1999-01-01

    The Loch Vale Watershed (LVWS) project was initiated in 1980 by the National Park Service with funding from the Aquatic Effects Research Program of the National Acid Precipitation Assessment Program. Initial research objectives were to understand the processes that would either mitigate or accelerate the effects of pollution on soil and surface water chemistry, and to build a record in which long-term trends could be identified and examined.It is important for all data collected in Loch Vale to meet the high standards of quality set forth in previous LVWS QA/QC reports and LVWS Methods Manuals. Given the ever-widening usage of data collected in Loch Vale, it is equally important to provide users of that data with a report assuring that all data are sound. Parameters covered in this report are the quality of meteorological measurements, hydrological measurements, surface water chemistry, and similarities in catch efficiency of two raingage types in Loch Vale for the period of 1995-1998.Routine sampling of weather conditions, precipitation chemistry, and stream/lake water chemistry began in 1982. Since then, all samples and data have been analyzed according to widely accepted and published methods. Weather data have been collected, analyzed, and stored by LVWS project personnel. Methods for the handling of meteorological data are well documented (Denning 1988, Edwards 1991, Newkirk 1995,and Allstott 1995). Precipitation chemistry has always been collected according to National Atmospheric Deposition Program protocol (Bigelow 1988), and analyzed at the Central Analytical Laboratory of the Illinois State Water Survey in Champaign, IL. QA/QC procedures of the National Atmospheric Deposition Program are well documented (Aubertin 1990). Protocols for sampling surface waters are also well documented (Newkirk 1995). Analysis of surface water chemistry has been performed using standard EPA protocol at the US Forest Service's Rocky Mt. Station Biogeochemistry Laboratory since 1993.

  4. Development of procedure for measurement of Pb isotope ratios in seawater by application of seaFAST sample pre-treatment system and Sector Field Inductively Coupled Plasma Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Vassileva, Emilia; Wysocka, Irena

    2016-12-01

    Anthropogenic Pb in the oceans, derived from high-temperature industrial processes, fuel combustion and incineration can have an isotopic signature distinct from naturally occurring Pb, supplied by rock weathering. To identify the different pollution sources accurately and to quantify their relative contributions, Pb isotope ratios are widely used. Due to the high salt content (approximately 3.5% of total dissolved solids) and very low levels of Pb (typically from 1 to 100 ng L- 1) in seawater the determination of Pb isotope ratios requires preliminary matrix separation and analyte preconcentration. An analytical protocol for the measurements of Pb isotope ratios in seawater combining seaFAST sample pre-treatment system and Sector Field Inductively Coupled Plasma Mass Spectrometry (SF ICP-MS) was developed. The application of seaFAST system was advantageous, because of its completely closed working cycle and small volumes of chemicals introduced in pre-treatment step, resulting in very low detection limits and procedural blanks. The preconcentration/matrix separation step was also of crucial importance for minimizing the isobaric and matrix interferences, coming from the seawater. In order to differentiate between anthropogenic and natural Pb sources, particular attention was paid to the determination of 204Pb isotope because of its implication in some geological interpretations. The validation of the analytical procedure was effectuated according to the recommendations of the ISO/IEC 17025 standard. The method was validated by processing the common Pb isotope reference material NIST SRM 981. All major sources of uncertainty were identified and propagated together following the ISO/GUM guidelines. The estimation of the total uncertainty associated to each measurement result was fundamental tool for sorting the main sources of possible biases. The developed analytical procedure was applied to the coastal and open seawater samples, collected in different regions of the world and revealed that the procedure is applicable for the measurement of Pb isotope ratios in seawater with combined uncertainty adequate to discuss the origin of Pb pollution in the ocean.

  5. Speciated arsenic in air: measurement methodology and risk assessment considerations.

    PubMed

    Lewis, Ari S; Reid, Kim R; Pollock, Margaret C; Campleman, Sharan L

    2012-01-01

    Accurate measurement of arsenic (As) in air is critical to providing a more robust understanding of arsenic exposures and associated human health risks. Although there is extensive information available on total arsenic in air, less is known on the relative contribution of each arsenic species. To address this data gap, the authors conducted an in-depth review of available information on speciated arsenic in air. The evaluation included the type of species measured and the relative abundance, as well as an analysis of the limitations of current analytical methods. Despite inherent differences in the procedures, most techniques effectively separated arsenic species in the air samples. Common analytical techniques such as inductively coupled plasma mass spectrometry (ICP-MS) and/or hydride generation (HG)- or quartz furnace (GF)-atomic absorption spectrometry (AAS) were used for arsenic measurement in the extracts, and provided some of the most sensitive detection limits. The current analysis demonstrated that, despite limited comparability among studies due to differences in seasonal factors, study duration, sample collection methods, and analytical methods, research conducted to date is adequate to show that arsenic in air is mainly in the inorganic form. Reported average concentrations of As(III) and As(V) ranged up to 7.4 and 10.4 ng/m3, respectively, with As(V) being more prevalent than As(III) in most studies. Concentrations of the organic methylated arsenic compounds are negligible (in the pg/m3 range). However because of the variability in study methods and measurement methodology, the authors were unable to determine the variation in arsenic composition as a function of source or particulate matter (PM) fraction. In this work, the authors include the implications of arsenic speciation in air on potential exposure and risks. The authors conclude that it is important to synchronize sample collection, preparation, and analytical techniques in order to generate data more useful for arsenic inhalation risk assessment, and a more robust documentation of quality assurance/quality control (QA/QC) protocols is necessary to ensure accuracy, precision, representativeness, and comparability.

  6. A Draft Test Protocol for Detecting Possible Biohazards in Martian Samples Returned to Earth

    NASA Technical Reports Server (NTRS)

    Rummel, John D.; Race, Margaret S.; DeVinenzi, Donald L.; Schad, P. Jackson; Stabekis, Pericles D.; Viso, Michel; Acevedo, Sara E.

    2002-01-01

    This document presents the first complete draft of a protocol for detecting possible biohazards in Mars samples returned to Earth; it is the final product of the Mars Sample Handling Protocol Workshop Series, convened in 2000-2001 by NASA's Planetary Protection Officer. The goal of the five-workshop Series vas to develop a comprehensive protocol by which returned martian sample materials could be assessed for the presence of any biological hazard(s) while safeguarding the purity of the samples from possible terrestrial contamination The reference numbers for the proceedings from the five individual Workshops.

  7. Dried Blood Spots - Preparing and Processing for Use in Immunoassays and in Molecular Techniques

    PubMed Central

    Grüner, Nico; Stambouli, Oumaima; Ross, R. Stefan

    2015-01-01

    The idea of collecting blood on a paper card and subsequently using the dried blood spots (DBS) for diagnostic purposes originated a century ago. Since then, DBS testing for decades has remained predominantly focused on the diagnosis of infectious diseases especially in resource-limited settings or the systematic screening of newborns for inherited metabolic disorders and only recently have a variety of new and innovative DBS applications begun to emerge. For many years, pre-analytical variables were only inappropriately considered in the field of DBS testing and even today, with the exception of newborn screening, the entire pre-analytical phase, which comprises the preparation and processing of DBS for their final analysis has not been standardized. Given this background, a comprehensive step-by-step protocol, which covers al the essential phases, is proposed, i.e., collection of blood; preparation of blood spots; drying of blood spots; storage and transportation of DBS; elution of DBS, and finally analyses of DBS eluates. The effectiveness of this protocol was first evaluated with 1,762 coupled serum/DBS pairs for detecting markers of hepatitis B virus, hepatitis C virus, and human immunodeficiency virus infections on an automated analytical platform. In a second step, the protocol was utilized during a pilot study, which was conducted on active drug users in the German cities of Berlin and Essen. PMID:25867233

  8. High heating rate thermal desorption for molecular surface sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ovchinnikova, Olga S.; Van Berkel, Gary J.

    2016-03-29

    A method for analyzing a sample having at least one analyte includes the step of heating the sample at a rate of at least 10.sup.6 K/s to thermally desorb at least one analyte from the sample. The desorbed analyte is collected. The analyte can then be analyzed.

  9. Enhanced spot preparation for liquid extractive sampling and analysis

    DOEpatents

    Van Berkel, Gary J.; King, Richard C.

    2015-09-22

    A method for performing surface sampling of an analyte, includes the step of placing the analyte on a stage with a material in molar excess to the analyte, such that analyte-analyte interactions are prevented and the analyte can be solubilized for further analysis. The material can be a matrix material that is mixed with the analyte. The material can be provided on a sample support. The analyte can then be contacted with a solvent to extract the analyte for further processing, such as by electrospray mass spectrometry.

  10. Magnetic solid phase extraction and static headspace gas chromatography-mass spectrometry method for the analysis of polycyclic aromatic hydrocarbons.

    PubMed

    Cai, Ying; Yan, Zhihong; Wang, Lijia; NguyenVan, Manh; Cai, Qingyun

    2016-01-15

    A magnetic solid phase extraction (MSPE) protocol combining a static headspace gas chromatography coupled to mass spectrometry (HS-GC-MS) method has been developed for extraction, and determination of 16 polycyclic aromatic hydrocarbons (PAHs) in drinking water samples. Magnetic nanoparticles (MNPs) were coated with 3-aminopropyltriethoxysilane and modified by cholesterol chloroformate. Transmission electron microscope, vibrating sample magnetometer, Fourier transform infrared spectrometry and X-ray photoelectron spectroscopy were used to characterize the cholesterol-functionalized sorbents, and the main parameters affecting the extraction as well as HS sampling, such as sorbent amount, extraction time, oven temperature and equilibration time have been investigated and established. Combination with HS sampling, the MSPE procedure was simple, fast and environmentally friendly, without need of any organic solvent. Method validation proved the feasibility of the developed sorbents for the quantitation of the investigated analytes at trace levels obtaining the limit of detection (S/N=3) ranging from 0.20 to 7.8 ng/L. Good values for intra and inter-day precision were obtained (RSDs ≤ 9.9%). The proposed method was successfully applied to drinking water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Compliance With Mobile Ecological Momentary Assessment Protocols in Children and Adolescents: A Systematic Review and Meta-Analysis

    PubMed Central

    2017-01-01

    Background Mobile device-based ecological momentary assessment (mobile-EMA) is increasingly used to collect participants' data in real-time and in context. Although EMA offers methodological advantages, these advantages can be diminished by participant noncompliance. However, evidence on how well participants comply with mobile-EMA protocols and how study design factors associated with participant compliance is limited, especially in the youth literature. Objective To systematically and meta-analytically examine youth’s compliance to mobile-EMA protocols and moderators of participant compliance in clinical and nonclinical settings. Methods Studies using mobile devices to collect EMA data among youth (age ≤18 years old) were identified. A systematic review was conducted to describe the characteristics of mobile-EMA protocols and author-reported factors associated with compliance. Random effects meta-analyses were conducted to estimate the overall compliance across studies and to explore factors associated with differences in youths’ compliance. Results This review included 42 unique studies that assessed behaviors, subjective experiences, and contextual information. Mobile phones were used as the primary mode of EMA data collection in 48% (20/42) of the reviewed studies. In total, 12% (5/42) of the studies used wearable devices in addition to the EMA data collection platforms. About half of the studies (62%, 24/42) recruited youth from nonclinical settings. Most (98%, 41/42) studies used a time-based sampling protocol. Among these studies, most (95%, 39/41) prompted youth 2-9 times daily, for a study length ranging from 2-42 days. Sampling frequency and study length did not differ between studies with participants from clinical versus nonclinical settings. Most (88%, 36/41) studies with a time-based sampling protocol defined compliance as the proportion of prompts to which participants responded. In these studies, the weighted average compliance rate was 78.3%. The average compliance rates were not different between studies with clinical (76.9%) and nonclinical (79.2%; P=.29) and studies that used only a mobile-EMA platform (77.4%) and mobile platform plus additional wearable devices (73.0%, P=.36). Among clinical studies, the mean compliance rate was significantly lower in studies that prompted participants 2-3 times (73.5%) or 4-5 times (66.9%) compared with studies with a higher sampling frequency (6+ times: 89.3%). Among nonclinical studies, a higher average compliance rate was observed in studies that prompted participants 2-3 times daily (91.7%) compared with those that prompted participants more frequently (4-5 times: 77.4%; 6+ times: 75.0%). The reported compliance rates did not differ by duration of EMA period among studies from either clinical or nonclinical settings. Conclusions The compliance rate among mobile-EMA studies in youth is moderate but suboptimal. Study design may affect protocol compliance differently between clinical and nonclinical participants; including additional wearable devices did not affect participant compliance. A more consistent compliance-related result reporting practices can facilitate understanding and improvement of participant compliance with EMA data collection among youth. PMID:28446418

  12. Numerical approach for unstructured quantum key distribution

    PubMed Central

    Coles, Patrick J.; Metodiev, Eric M.; Lütkenhaus, Norbert

    2016-01-01

    Quantum key distribution (QKD) allows for communication with security guaranteed by quantum theory. The main theoretical problem in QKD is to calculate the secret key rate for a given protocol. Analytical formulas are known for protocols with symmetries, since symmetry simplifies the analysis. However, experimental imperfections break symmetries, hence the effect of imperfections on key rates is difficult to estimate. Furthermore, it is an interesting question whether (intentionally) asymmetric protocols could outperform symmetric ones. Here we develop a robust numerical approach for calculating the key rate for arbitrary discrete-variable QKD protocols. Ultimately this will allow researchers to study ‘unstructured' protocols, that is, those that lack symmetry. Our approach relies on transforming the key rate calculation to the dual optimization problem, which markedly reduces the number of parameters and hence the calculation time. We illustrate our method by investigating some unstructured protocols for which the key rate was previously unknown. PMID:27198739

  13. RNA-DNA hybrid (R-loop) immunoprecipitation mapping: an analytical workflow to evaluate inherent biases

    PubMed Central

    Halász, László; Karányi, Zsolt; Boros-Oláh, Beáta; Kuik-Rózsa, Tímea; Sipos, Éva; Nagy, Éva; Mosolygó-L, Ágnes; Mázló, Anett; Rajnavölgyi, Éva; Halmos, Gábor; Székvölgyi, Lóránt

    2017-01-01

    The impact of R-loops on the physiology and pathology of chromosomes has been demonstrated extensively by chromatin biology research. The progress in this field has been driven by technological advancement of R-loop mapping methods that largely relied on a single approach, DNA-RNA immunoprecipitation (DRIP). Most of the DRIP protocols use the experimental design that was developed by a few laboratories, without paying attention to the potential caveats that might affect the outcome of RNA-DNA hybrid mapping. To assess the accuracy and utility of this technology, we pursued an analytical approach to estimate inherent biases and errors in the DRIP protocol. By performing DRIP-sequencing, qPCR, and receiver operator characteristic (ROC) analysis, we tested the effect of formaldehyde fixation, cell lysis temperature, mode of genome fragmentation, and removal of free RNA on the efficacy of RNA-DNA hybrid detection and implemented workflows that were able to distinguish complex and weak DRIP signals in a noisy background with high confidence. We also show that some of the workflows perform poorly and generate random answers. Furthermore, we found that the most commonly used genome fragmentation method (restriction enzyme digestion) led to the overrepresentation of lengthy DRIP fragments over coding ORFs, and this bias was enhanced at the first exons. Biased genome sampling severely compromised mapping resolution and prevented the assignment of precise biological function to a significant fraction of R-loops. The revised workflow presented herein is established and optimized using objective ROC analyses and provides reproducible and highly specific RNA-DNA hybrid detection. PMID:28341774

  14. Precise U and Pu isotope ratio measurements in nuclear samples by hyphenating capillary electrophoresis and MC-ICPMS.

    PubMed

    Martelat, Benoit; Isnard, Helene; Vio, Laurent; Dupuis, Erwan; Cornet, Terence; Nonell, Anthony; Chartier, Frederic

    2018-06-22

    Precise isotopic and elemental characterization of spent nuclear fuel is a major concern for the validation of the neutronic calculation codes and waste management strategy in the nuclear industry. Generally, the elements of interest, particularly U and Pu which are the two major elements present in spent fuel, are purified by ion exchange or extractant resins before off-line measurements by thermal ionization mass spectrometry. The aim of the present work was to develop a new analytical approach based on capillary electrophoresis (CE) hyphenated to a multicollector inductively coupled plasma mass spectrometer (MC-ICPMS) for online isotope ratio measurements. An electrophoretic separation protocol of U, Pu and the fraction containing fission products and minor actinides (Am and Cm) was developed using acetic acid as the electrolyte and complexing agent. The instrumentation for CE was designed to be used in a glove box and a laboratory-built interface was developed for hyphenation with MC-ICPMS. The separation was realized with only a few nL of a solution of spent nuclear fuel and the reproducibilities obtained on the U and Pu isotope ratios were on the order of a few ‰ which is comparable to those obtained by thermal ionization mass spectrometer (TIMS). This innovative protocol allowed a tremendous reduction of the analyte masses from μg to ng and also a drastic reduction of the liquid waste production from mL to μL. In addition, the time of analysis was shorted by at least a factor three. All of these improved parameters are of major interest for nuclear applications.

  15. 2D-DIGE in Proteomics.

    PubMed

    Pasquali, Matias; Serchi, Tommaso; Planchon, Sebastien; Renaut, Jenny

    2017-01-01

    The two-dimensional difference gel electrophoresis method is a valuable approach for proteomics. The method, using cyanine fluorescent dyes, allows the co-migration of multiple protein samples in the same gel and their simultaneous detection, thus reducing experimental and analytical time. 2D-DIGE, compared to traditional post-staining 2D-PAGE protocols (e.g., colloidal Coomassie or silver nitrate), provides faster and more reliable gel matching, limiting the impact of gel to gel variation, and allows also a good dynamic range for quantitative comparisons. By the use of internal standards, it is possible to normalize for experimental variations in spot intensities and gel patterns. Here we describe the experimental steps we follow in our routine 2D-DIGE procedure that we then apply to multiple biological questions.

  16. QA/QC in the laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hood, F.C.

    1992-05-01

    Quality assurance and quality control (QA/QC) of analytical chemistry laboratory activities are essential to the validity and usefulness of resultant data. However, in themselves, conventional QA/QC measures will not always ensure that fraudulent data are not generated. Conventional QA/QC measures are based on the assumption that work will be done in good faith; to assure against fraudulent practices, QA/QC measures must be tailored to specific analyses protocols in anticipation of intentional misapplication of those protocols. Application of specific QA/QC measures to ensure against fraudulent practices result in an increased administrative burden being placed on the analytical process; accordingly, in keepingmore » with graded QA philosophy, data quality objectives must be used to identify specific points of concern for special control to minimize the administrative impact.« less

  17. QA/QC in the laboratory. Session F

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hood, F.C.

    1992-05-01

    Quality assurance and quality control (QA/QC) of analytical chemistry laboratory activities are essential to the validity and usefulness of resultant data. However, in themselves, conventional QA/QC measures will not always ensure that fraudulent data are not generated. Conventional QA/QC measures are based on the assumption that work will be done in good faith; to assure against fraudulent practices, QA/QC measures must be tailored to specific analyses protocols in anticipation of intentional misapplication of those protocols. Application of specific QA/QC measures to ensure against fraudulent practices result in an increased administrative burden being placed on the analytical process; accordingly, in keepingmore » with graded QA philosophy, data quality objectives must be used to identify specific points of concern for special control to minimize the administrative impact.« less

  18. Bias Assessment of General Chemistry Analytes using Commutable Samples.

    PubMed

    Koerbin, Gus; Tate, Jillian R; Ryan, Julie; Jones, Graham Rd; Sikaris, Ken A; Kanowski, David; Reed, Maxine; Gill, Janice; Koumantakis, George; Yen, Tina; St John, Andrew; Hickman, Peter E; Simpson, Aaron; Graham, Peter

    2014-11-01

    Harmonisation of reference intervals for routine general chemistry analytes has been a goal for many years. Analytical bias may prevent this harmonisation. To determine if analytical bias is present when comparing methods, the use of commutable samples, or samples that have the same properties as the clinical samples routinely analysed, should be used as reference samples to eliminate the possibility of matrix effect. The use of commutable samples has improved the identification of unacceptable analytical performance in the Netherlands and Spain. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has undertaken a pilot study using commutable samples in an attempt to determine not only country specific reference intervals but to make them comparable between countries. Australia and New Zealand, through the Australasian Association of Clinical Biochemists (AACB), have also undertaken an assessment of analytical bias using commutable samples and determined that of the 27 general chemistry analytes studied, 19 showed sufficiently small between method biases as to not prevent harmonisation of reference intervals. Application of evidence based approaches including the determination of analytical bias using commutable material is necessary when seeking to harmonise reference intervals.

  19. Distributed electrochemical sensors: recent advances and barriers to market adoption.

    PubMed

    Hoekstra, Rafael; Blondeau, Pascal; Andrade, Francisco J

    2018-07-01

    Despite predictions of their widespread application in healthcare and environmental monitoring, electrochemical sensors are yet to be distributed at scale, instead remaining largely confined to R&D labs. This contrasts sharply with the situation for physical sensors, which are now ubiquitous and seamlessly embedded in the mature ecosystem provided by electronics and connectivity protocols. Although chemical sensors could be integrated into the same ecosystem, there are fundamental issues with these sensors in the three key areas of analytical performance, usability, and affordability. Nevertheless, advances are being made in each of these fields, leading to hope that the deployment of automated and user-friendly low-cost electrochemical sensors is on the horizon. Here, we present a brief survey of key challenges and advances in the development of distributed electrochemical sensors for liquid samples, geared towards applications in healthcare and wellbeing, environmental monitoring, and homeland security. As will be seen, in many cases the analytical performance of the sensor is acceptable; it is usability that is the major barrier to commercial viability at this moment. Were this to be overcome, the issue of affordability could be addressed. Graphical Abstract ᅟ.

  20. Effect of modulation of the particle size distributions in the direct solid analysis by total-reflection X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Fernández-Ruiz, Ramón; Friedrich K., E. Josue; Redrejo, M. J.

    2018-02-01

    The main goal of this work was to investigate, in a systematic way, the influence of the controlled modulation of the particle size distribution of a representative solid sample with respect to the more relevant analytical parameters of the Direct Solid Analysis (DSA) by Total-reflection X-Ray Fluorescence (TXRF) quantitative method. In particular, accuracy, uncertainty, linearity and detection limits were correlated with the main parameters of their size distributions for the following elements; Al, Si, P, S, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Rb, Sr, Ba and Pb. In all cases strong correlations were finded. The main conclusion of this work can be resumed as follows; the modulation of particles shape to lower average sizes next to a minimization of the width of particle size distributions, produce a strong increment of accuracy, minimization of uncertainties and limit of detections for DSA-TXRF methodology. These achievements allow the future use of the DSA-TXRF analytical methodology for development of ISO norms and standardized protocols for the direct analysis of solids by mean of TXRF.

  1. MicroRNA Based Liquid Biopsy: The Experience of the Plasma miRNA Signature Classifier (MSC) for Lung Cancer Screening.

    PubMed

    Mensah, Mavis; Borzi, Cristina; Verri, Carla; Suatoni, Paola; Conte, Davide; Pastorino, Ugo; Orazio, Fortunato; Sozzi, Gabriella; Boeri, Mattia

    2017-10-26

    The development of a minimally invasive test, such as liquid biopsy, for early lung cancer detection in its preclinical phase is crucial to improve the outcome of this deadly disease. MicroRNAs (miRNAs) are tissue specific, small, non-coding RNAs regulating gene expression, which may act as extracellular messengers of biological signals derived from the cross-talk between the tumor and its surrounding microenvironment. They could thus represent ideal candidates for early detection of lung cancer. In this work, a methodological workflow for the prospective validation of a circulating miRNA test using custom made microfluidic cards and quantitative Real-Time PCR in plasma samples of volunteers enrolled in a lung cancer screening trial is proposed. In addition, since the release of hemolysis-related miRNAs and more general technical issues may affect the analysis, the quality control steps included in the standard operating procedures are also presented. The protocol is reproducible and gives reliable quantitative results; however, when using large clinical series, both pre-analytical and analytical features should be cautiously evaluated.

  2. Molecular imaging of cannabis leaf tissue with MeV-SIMS method

    NASA Astrophysics Data System (ADS)

    Jenčič, Boštjan; Jeromel, Luka; Ogrinc Potočnik, Nina; Vogel-Mikuš, Katarina; Kovačec, Eva; Regvar, Marjana; Siketić, Zdravko; Vavpetič, Primož; Rupnik, Zdravko; Bučar, Klemen; Kelemen, Mitja; Kovač, Janez; Pelicon, Primož

    2016-03-01

    To broaden our analytical capabilities with molecular imaging in addition to the existing elemental imaging with micro-PIXE, a linear Time-Of-Flight mass spectrometer for MeV Secondary Ion Mass Spectrometry (MeV-SIMS) was constructed and added to the existing nuclear microprobe at the Jožef Stefan Institute. We measured absolute molecular yields and damage cross-section of reference materials, without significant alteration of the fragile biological samples during the duration of measurements in the mapping mode. We explored the analytical capability of the MeV-SIMS technique for chemical mapping of the plant tissue of medicinal cannabis leaves. A series of hand-cut plant tissue slices were prepared by standard shock-freezing and freeze-drying protocol and deposited on the Si wafer. We show the measured MeV-SIMS spectra showing a series of peaks in the mass area of cannabinoids, as well as their corresponding maps. The indicated molecular distributions at masses of 345.5 u and 359.4 u may be attributed to the protonated THCA and THCA-C4 acids, and show enhancement in the areas with opened trichome morphology.

  3. CE separation of proteins and yeasts dynamically modified by PEG pyrenebutanoate with fluorescence detection.

    PubMed

    Horká, Marie; Růzicka, Filip; Holá, Veronika; Slais, Karel

    2007-07-01

    The optimized protocols of the bioanalytes separation, proteins and yeasts, dynamically modified by the nonionogenic tenside PEG pyrenebutanoate, were applied in CZE and CIEF with the acidic gradient in pH range 2-5.5, both with fluorescence detection. PEG pyrenebutanoate was used as a buffer additive for a dynamic modification of proteins and/or yeast samples. The narrow peaks of modified analytes were detected. The values of the pI's of the labeled proteins were calculated using new fluorescent pI markers in CIEF and they were found to be comparable with pI's of the native compounds. As an example of the possible use of the suggested CIEF technique, the mixed cultures of yeasts, Candida albicans, Candida glabrata, Candida kefyr, Candida krusei, Candida lusitaniae, Candida parapsilosis, Candida tropicalis, Candida zeylanoides, Geotrichum candidum, Saccharomyces cerevisiae, Trichosporon asahii and Yarrowia lipolytica, were reproducibly focused and separated with high sensitivity. Using UV excitation for the on-column fluorometric detection, the minimum detectable amounts of analytes, femtograms of proteins and down to ten cells injected on the separation capillary, were estimated.

  4. Surface imprinted beads for the recognition of human serum albumin.

    PubMed

    Bonini, Francesca; Piletsky, Sergey; Turner, Anthony P F; Speghini, Adolfo; Bossi, Alessandra

    2007-04-15

    The synthesis of poly-aminophenylboronic acid (ABPA) imprinted beads for the recognition of the protein human serum albumin (HSA) is reported. In order to create homogeneous recognition sites, covalent immobilisation of the template HSA was exploited. The resulting imprinted beads were selective for HSA. The indirect imprinting factor (IF) calculated from supernatant was 1.6 and the direct IF, evaluated from the protein recovered from the beads, was 1.9. The binding capacity was 1.4 mg/g, which is comparable to commercially available affinity materials. The specificity of the HSA recognition was evaluated with competitive experiments, indicating a molar ratio 4.5/1 of competitor was necessary to displace half of the bound HSA. The recognition and binding of the imprinted beads was also tested with a complex sample, human serum and targeted removal of HSA without a loss of the other protein components was demonstrated. The easy preparation protocol of derivatised beads and a good protein recognition properties make the approach an attractive solution to analytical and bio-analytical problems in the field of biotechnology.

  5. Microfluidic-Based sample chips for radioactive solutions

    DOE PAGES

    Tripp, J. L.; Law, J. D.; Smith, T. E.; ...

    2015-01-01

    Historical nuclear fuel cycle process sampling techniques required sample volumes ranging in the tens of milliliters. The radiation levels experienced by analytical personnel and equipment, in addition to the waste volumes generated from analysis of these samples, have been significant. These sample volumes also impacted accountability inventories of required analytes during process operations. To mitigate radiation dose and other issues associated with the historically larger sample volumes, a microcapillary sample chip was chosen for further investigation. The ability to obtain microliter volume samples coupled with a remote automated means of sample loading, tracking, and transporting to the analytical instrument wouldmore » greatly improve analytical efficiency while reducing both personnel exposure and radioactive waste volumes. Sample chip testing was completed to determine the accuracy, repeatability, and issues associated with the use of microfluidic sample chips used to supply µL sample volumes of lanthanide analytes dissolved in nitric acid for introduction to an analytical instrument for elemental analysis.« less

  6. Hydrodynamic size-based separation and characterization of protein aggregates from total cell lysates

    PubMed Central

    Tanase, Maya; Zolla, Valerio; Clement, Cristina C; Borghi, Francesco; Urbanska, Aleksandra M; Rodriguez-Navarro, Jose Antonio; Roda, Barbara; Zattoni, Andrea; Reschiglian, Pierluigi; Cuervo, Ana Maria; Santambrogio, Laura

    2016-01-01

    Herein we describe a protocol that uses hollow-fiber flow field-flow fractionation (FFF) coupled with multiangle light scattering (MALS) for hydrodynamic size-based separation and characterization of complex protein aggregates. The fractionation method, which requires 1.5 h to run, was successfully modified from the analysis of protein aggregates, as found in simple protein mixtures, to complex aggregates, as found in total cell lysates. In contrast to other related methods (filter assay, analytical ultracentrifugation, gel electrophoresis and size-exclusion chromatography), hollow-fiber flow FFF coupled with MALS allows a flow-based fractionation of highly purified protein aggregates and simultaneous measurement of their molecular weight, r.m.s. radius and molecular conformation (e.g., round, rod-shaped, compact or relaxed). The polyethersulfone hollow fibers used, which have a 0.8-mm inner diameter, allow separation of as little as 20 μg of total cell lysates. In addition, the ability to run the samples in different denaturing and nondenaturing buffer allows defining true aggregates from artifacts, which can form during sample preparation. The protocol was set up using Paraquat-induced carbonylation, a model that induces protein aggregation in cultured cells. This technique will advance the biochemical, proteomic and biophysical characterization of molecular-weight aggregates associated with protein mutations, as found in many CNS degenerative diseases, or chronic oxidative stress, as found in aging, and chronic metabolic and inflammatory conditions. PMID:25521790

  7. Rapid detection of 21-hydroxylase deficiency mutations by allele-specific in vitro amplification and capillary zone electrophoresis.

    PubMed

    Carrera, P; Barbieri, A M; Ferrari, M; Righetti, P G; Perego, M; Gelfi, C

    1997-11-01

    A quick diagnosis of the classic form of 21-hydroxylase deficiency (simple virilizing and salt wasting) is of great importance, especially for prenatal diagnosis and treatment in pregnancies at risk. A method for simultaneous detection of common point mutations in the P450c21 B gene is here proposed by combining a nested PCR amplification refractory mutation system (ARMS) with capillary zone electrophoresis (CZE) in sieving liquid polymers. In the first PCR, B genes are selectively amplified. In the nested reaction, ARMS-detected wild-type and mutated alleles are separately pooled and resolved by CZE. CZE is performed in coated capillaries in the presence of 30 g/L hydroxyethyl cellulose in the background electrolyte for size separation of the DNA analytes. For high-sensitivity detection the electrophoresis buffer contains the fluorescent dye SYBR Green I. Laser-induced fluorescence detection is obtained by excitation at 488 nm and signal collection at 520 nm. Specificity and reproducibility of the protocols were established by using samples from 75 Italian families with 21-hydroxylase deficiency already genotyped by allele-specific oligonucleotide hybridization or direct sequencing. Whereas dot-blot is time consuming because of the high number of hybridizations with radioactive probes, this present protocol is more rapid, giving sufficient separation on CZE after PCR reactions without preconcentration or desalting of samples.

  8. Size characterization by Sedimentation Field Flow Fractionation of silica particles used as food additives.

    PubMed

    Contado, Catia; Ravani, Laura; Passarella, Martina

    2013-07-25

    Four types of SiO2, available on the market as additives in food and personal care products, were size characterized using Sedimentation Field Flow Fractionation (SdFFF), SEM, TEM and Photon Correlation Spectroscopy (PCS). The synergic use of the different analytical techniques made it possible, for some samples, to confirm the presence of primary nanoparticles (10 nm) organized in clusters or aggregates of different dimension and, for others, to discover that the available information is incomplete, particularly that regarding the presence of small particles. A protocol to extract the silica particles from a simple food matrix was set up, enriching (0.25%, w w(-1)) a nearly silica-free instant barley coffee powder with a known SiO2 sample. The SdFFF technique, in conjunction with SEM observations, made it possible to identify the added SiO2 particles and verify the new particle size distribution. The SiO2 content of different powdered foodstuffs was determined by graphite furnace atomic absorption spectroscopy (GFAAS); the concentrations ranged between 0.006 and 0.35% (w w(-1)). The protocol to isolate the silica particles was so applied to the most SiO2-rich commercial products and the derived suspensions were separated by SdFFF; SEM and TEM observations supported the size analyses while GFAAS determinations on collected fractions permitted element identification. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Design and Analysis of A Beacon-Less Routing Protocol for Large Volume Content Dissemination in Vehicular Ad Hoc Networks.

    PubMed

    Hu, Miao; Zhong, Zhangdui; Ni, Minming; Baiocchi, Andrea

    2016-11-01

    Large volume content dissemination is pursued by the growing number of high quality applications for Vehicular Ad hoc NETworks(VANETs), e.g., the live road surveillance service and the video-based overtaking assistant service. For the highly dynamical vehicular network topology, beacon-less routing protocols have been proven to be efficient in achieving a balance between the system performance and the control overhead. However, to the authors' best knowledge, the routing design for large volume content has not been well considered in the previous work, which will introduce new challenges, e.g., the enhanced connectivity requirement for a radio link. In this paper, a link Lifetime-aware Beacon-less Routing Protocol (LBRP) is designed for large volume content delivery in VANETs. Each vehicle makes the forwarding decision based on the message header information and its current state, including the speed and position information. A semi-Markov process analytical model is proposed to evaluate the expected delay in constructing one routing path for LBRP. Simulations show that the proposed LBRP scheme outperforms the traditional dissemination protocols in providing a low end-to-end delay. The analytical model is shown to exhibit a good match on the delay estimation with Monte Carlo simulations, as well.

  10. Design and Analysis of A Beacon-Less Routing Protocol for Large Volume Content Dissemination in Vehicular Ad Hoc Networks

    PubMed Central

    Hu, Miao; Zhong, Zhangdui; Ni, Minming; Baiocchi, Andrea

    2016-01-01

    Large volume content dissemination is pursued by the growing number of high quality applications for Vehicular Ad hoc NETworks(VANETs), e.g., the live road surveillance service and the video-based overtaking assistant service. For the highly dynamical vehicular network topology, beacon-less routing protocols have been proven to be efficient in achieving a balance between the system performance and the control overhead. However, to the authors’ best knowledge, the routing design for large volume content has not been well considered in the previous work, which will introduce new challenges, e.g., the enhanced connectivity requirement for a radio link. In this paper, a link Lifetime-aware Beacon-less Routing Protocol (LBRP) is designed for large volume content delivery in VANETs. Each vehicle makes the forwarding decision based on the message header information and its current state, including the speed and position information. A semi-Markov process analytical model is proposed to evaluate the expected delay in constructing one routing path for LBRP. Simulations show that the proposed LBRP scheme outperforms the traditional dissemination protocols in providing a low end-to-end delay. The analytical model is shown to exhibit a good match on the delay estimation with Monte Carlo simulations, as well. PMID:27809285

  11. Protocols for dry DNA storage and shipment at room temperature.

    PubMed

    Ivanova, Natalia V; Kuzmina, Masha L

    2013-09-01

    The globalization of DNA barcoding will require core analytical facilities to develop cost-effective, efficient protocols for the shipment and archival storage of DNA extracts and PCR products. We evaluated three dry-state DNA stabilization systems: commercial Biomatrica(®) DNAstable(®) plates, home-made trehalose and polyvinyl alcohol (PVA) plates on 96-well panels of insect DNA stored at 56 °C and at room temperature. Controls included unprotected samples that were stored dry at room temperature and at 56 °C, and diluted samples held at 4 °C and at -20 °C. PCR and selective sequencing were performed over a 4-year interval to test the condition of DNA extracts. Biomatrica(®) provided better protection of DNA at 56 °C and at room temperature than trehalose and PVA, especially for diluted samples. PVA was the second best protectant after Biomatrica(®) at room temperature, whereas trehalose was the second best protectant at 56 °C. In spite of lower PCR success, the DNA stored at -20 °C yielded longer sequence reads and stronger signal, indicating that temperature is a crucial factor for DNA quality which has to be considered especially for long-term storage. Although it is premature to advocate a transition to DNA storage at room temperature, dry storage provides an additional layer of security for frozen samples, protecting them from degradation in the event of freezer failure. All three forms of DNA preservation enable shipment of dry DNA and PCR products between barcoding facilities. © 2013 The Authors. Molecular Ecology Resources published by John Wiley & Sons Ltd.

  12. Automated High-Throughput Permethylation for Glycosylation Analysis of Biologics Using MALDI-TOF-MS.

    PubMed

    Shubhakar, Archana; Kozak, Radoslaw P; Reiding, Karli R; Royle, Louise; Spencer, Daniel I R; Fernandes, Daryl L; Wuhrer, Manfred

    2016-09-06

    Monitoring glycoprotein therapeutics for changes in glycosylation throughout the drug's life cycle is vital, as glycans significantly modulate the stability, biological activity, serum half-life, safety, and immunogenicity. Biopharma companies are increasingly adopting Quality by Design (QbD) frameworks for measuring, optimizing, and controlling drug glycosylation. Permethylation of glycans prior to analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) is a valuable tool for glycan characterization and for screening of large numbers of samples in QbD drug realization. However, the existing protocols for manual permethylation and liquid-liquid extraction (LLE) steps are labor intensive and are thus not practical for high-throughput (HT) studies. Here we present a glycan permethylation protocol, based on 96-well microplates, that has been developed into a kit suitable for HT work. The workflow is largely automated using a liquid handling robot and includes N-glycan release, enrichment of N-glycans, permethylation, and LLE. The kit has been validated according to industry analytical performance guidelines and applied to characterize biopharmaceutical samples, including IgG4 monoclonal antibodies (mAbs) and recombinant human erythropoietin (rhEPO). The HT permethylation enabled glycan characterization and relative quantitation with minimal side reactions: the MALDI-TOF-MS profiles obtained were in good agreement with hydrophilic liquid interaction chromatography (HILIC) and ultrahigh performance liquid chromatography (UHPLC) data. Automated permethylation and extraction of 96 glycan samples was achieved in less than 5 h and automated data acquisition on MALDI-TOF-MS took on average less than 1 min per sample. This automated and HT glycan preparation and permethylation showed to be convenient, fast, and reliable and can be applied for drug glycan profiling and clinical glycan biomarker studies.

  13. Study protocol for the translating research in elder care (TREC): building context – an organizational monitoring program in long-term care project (project one)

    PubMed Central

    Estabrooks, Carole A; Squires, Janet E; Cummings, Greta G; Teare, Gary F; Norton, Peter G

    2009-01-01

    Background While there is a growing awareness of the importance of organizational context (or the work environment/setting) to successful knowledge translation, and successful knowledge translation to better patient, provider (staff), and system outcomes, little empirical evidence supports these assumptions. Further, little is known about the factors that enhance knowledge translation and better outcomes in residential long-term care facilities, where care has been shown to be suboptimal. The project described in this protocol is one of the two main projects of the larger five-year Translating Research in Elder Care (TREC) program. Aims The purpose of this project is to establish the magnitude of the effect of organizational context on knowledge translation, and subsequently on resident, staff (unregulated, regulated, and managerial) and system outcomes in long-term care facilities in the three Canadian Prairie Provinces (Alberta, Saskatchewan, Manitoba). Methods/Design This study protocol describes the details of a multi-level – including provinces, regions, facilities, units within facilities, and individuals who receive care (residents) or work (staff) in facilities – and longitudinal (five-year) research project. A stratified random sample of 36 residential long-term care facilities (30 urban and 6 rural) from the Canadian Prairie Provinces will comprise the sample. Caregivers and care managers within these facilities will be asked to complete the TREC survey – a suite of survey instruments designed to assess organizational context and related factors hypothesized to be important to successful knowledge translation and to achieving better resident, staff, and system outcomes. Facility and unit level data will be collected using standardized data collection forms, and resident outcomes using the Resident Assessment Instrument-Minimum Data Set version 2.0 instrument. A variety of analytic techniques will be employed including descriptive analyses, psychometric analyses, multi-level modeling, and mixed-method analyses. Discussion Three key challenging areas associated with conducting this project are discussed: sampling, participant recruitment, and sample retention; survey administration (with unregulated caregivers); and the provision of a stable set of study definitions to guide the project. PMID:19671166

  14. Squeezed-state quantum key distribution with a Rindler observer

    NASA Astrophysics Data System (ADS)

    Zhou, Jian; Shi, Ronghua; Guo, Ying

    2018-03-01

    Lengthening the maximum transmission distance of quantum key distribution plays a vital role in quantum information processing. In this paper, we propose a directional squeezed-state protocol with signals detected by a Rindler observer in the relativistic quantum field framework. We derive an analytical solution to the transmission problem of squeezed states from the inertial sender to the accelerated receiver. The variance of the involved signal mode is closer to optimality than that of the coherent-state-based protocol. Simulation results show that the proposed protocol has better performance than the coherent-state counterpart especially in terms of the maximal transmission distance.

  15. Determination of caramel colorants' by-products in liquid foods by ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS).

    PubMed

    Goscinny, Séverine; Hanot, Vincent; Trabelsi, Hasna; Van Loco, Joris

    2014-01-01

    2-Methylimidazole, 4-methylimidazole (2-MI and 4-MI), 2-acetyl-4-(1,2,3,4-tetrahydroxybutyl) imidazole (THI) and 5-hydroxymethylfurfural (5-HMF) are neo-formed compounds generated during the manufacture of caramel colours and are transferred to the processed food. These contaminants are known to have a toxicological profile that may pose health risks. Hence, to characterise THI, 2- and 4-MI and 5-HMF levels in liquid foods, an ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and sample preparation was divided into two analytical strategies depending on the concentration range expected in the type of foods targeted. For the determination of the imidazole substitutes (THI, 2- and 4-MI), a sample enrichment and clean-up step by strong cation solid-phase extraction was developed. This method is capable of quantifying over a range of 5 ng ml⁻¹ (LOQ) to 500 ng ml⁻¹ with recoveries of 75.4-112.4% and RSDs of 1.5-15%. For determination of 5-HMF, a standard addition method was applied covering the linear range of 0.25-30 µg ml⁻¹ with RSDs from 2.8% (for intraday precision) to 9.2% (for intermediate precision). The validated analytical methods were applied to 28 liquid food samples purchased from local markets. THI was found only in the beer samples at levels up to 141.2 ng ml⁻¹. For 2-MI, non-quantifiable traces were observed for all samples, while 4-MI was observed in all samples with large concentration variations (from < LOQ to 563.9 ng ml⁻¹). 5-HMF was found at expected concentrations, except for a sherry vinegar sample (113 µg ml⁻¹), which required a high level of dilution before following the standard addition protocol.

  16. Cell-based quantification of biomarkers from an ultra-fast microfluidic immunofluorescent staining: application to human breast cancer cell lines

    NASA Astrophysics Data System (ADS)

    Migliozzi, D.; Nguyen, H. T.; Gijs, M. A. M.

    2018-02-01

    Immunohistochemistry (IHC) is one of the main techniques currently used in the clinics for biomarker characterization. It consists in colorimetric labeling with specific antibodies followed by microscopy analysis. The results are then used for diagnosis and therapeutic targeting. Well-known drawbacks of such protocols are their limited accuracy and precision, which prevent the clinicians from having quantitative and robust IHC results. With our work, we combined rapid microfluidic immunofluorescent staining with efficient image-based cell segmentation and signal quantification to increase the robustness of both experimental and analytical protocols. The experimental protocol is very simple and based on fast-fluidic-exchange in a microfluidic chamber created on top of the formalin-fixed-paraffin-embedded (FFPE) slide by clamping it a silicon chip with a polydimethyl siloxane (PDMS) sealing ring. The image-processing protocol is based on enhancement and subsequent thresholding of the local contrast of the obtained fluorescence image. As a case study, given that the human epidermal growth factor receptor 2 (HER2) protein is often used as a biomarker for breast cancer, we applied our method to HER2+ and HER2- cell lines. We report very fast (5 minutes) immunofluorescence staining of both HER2 and cytokeratin (a marker used to define the tumor region) on FFPE slides. The image-processing program can segment cells correctly and give a cell-based quantitative immunofluorescent signal. With this method, we found a reproducible well-defined separation for the HER2-to-cytokeratin ratio for positive and negative control samples.

  17. Meta-analytical assessment of the effects of protocol variations on cortisol responses to the Trier Social Stress Test.

    PubMed

    Goodman, William K; Janson, Johanna; Wolf, Jutta M

    2017-06-01

    The Trier Social Stress Test (TSST) is one of the most widely used laboratory stress tests. Exposure to this psychosocial stressor has been shown to stimulate an acute cortisol stress response in the majority of healthy individuals, while deviations from the typical pattern, i.e., cortisol reactivity dysfunctions have been linked to an ever-increasing number of negative health outcomes. However, significant variability between labs exists in strength of observed cortisol responses in healthy individuals. This variability raises the question of how to distinguish across labs between cortisol stress response patterns that reflect health risk from those that are due to methodological differences. Thus, we propose a systematic review and meta-analysis that aims at quantifying the effects of methodological variation in study and TSST protocol elements on cortisol stress responses in healthy individuals. Literature searches were conducted using standard databases for English language with key words including Trier Social Stress Test, TSST, Cortisol, and Laboratory Stressor among others. 186 studies met our inclusion criteria of healthy human participants without systemic immunological or endocrine dysfunction and provided sufficient information to compute a total of 237 sub-sample effect sizes. With regard to study protocol variations that may risk confounding baseline cortisol values and thus influence subsequent reactivity measures, meta-analytical examination revealed that acclimation periods pre-TSST below 30 or perhaps even 15min may suffice, at least as long as no interfering activities, i.e., questionnaires, are taking place during that timeframe. Assessing the effects of TSST protocol variations on cortisol response strength, several observations are noteworthy. First, shortening speech preparation time did not change cortisol responses in any way, nor did including questionnaires during that period show an effect. As such, our findings suggest that speech preparation time is one TSST element that can be used to reduce the burden for participants as well as laboratory logistics. Secondly, having an all female panel and instructing panel members to show negative instead of neutral behavior towards the participants both were associated with considerably reduced cortisol stress response strengths. Thirdly, several variables of interest, such as content of the speech task or gender match between active panel member and participant, were problematic to evaluate due to the large number of studies not reporting those details. This calls for future studies to report more details regarding potentially relevant protocol specifications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. RE-EVALUATION OF APPLICABILITY OF AGENCY SAMPLE HOLDING TIMES

    EPA Science Inventory

    Holding times are the length of time a sample can be stored after collection and prior to analysis without significantly affecting the analytical results. Holding times vary with the analyte, sample matrix, and analytical methodology used to quantify the analytes concentration. ...

  19. Analytical Performance Characteristics of the Cepheid GeneXpert Ebola Assay for the Detection of Ebola Virus

    PubMed Central

    Pinsky, Benjamin A.; Sahoo, Malaya K.; Sandlund, Johanna; Kleman, Marika; Kulkarni, Medha; Grufman, Per; Nygren, Malin; Kwiatkowski, Robert; Baron, Ellen Jo; Tenover, Fred; Denison, Blake; Higuchi, Russell; Van Atta, Reuel; Beer, Neil Reginald; Carrillo, Alda Celena; Naraghi-Arani, Pejman; Mire, Chad E.; Ranadheera, Charlene; Grolla, Allen; Lagerqvist, Nina; Persing, David H.

    2015-01-01

    Background The recently developed Xpert® Ebola Assay is a novel nucleic acid amplification test for simplified detection of Ebola virus (EBOV) in whole blood and buccal swab samples. The assay targets sequences in two EBOV genes, lowering the risk for new variants to escape detection in the test. The objective of this report is to present analytical characteristics of the Xpert® Ebola Assay on whole blood samples. Methods and Findings This study evaluated the assay’s analytical sensitivity, analytical specificity, inclusivity and exclusivity performance in whole blood specimens. EBOV RNA, inactivated EBOV, and infectious EBOV were used as targets. The dynamic range of the assay, the inactivation of virus, and specimen stability were also evaluated. The lower limit of detection (LoD) for the assay using inactivated virus was estimated to be 73 copies/mL (95% CI: 51–97 copies/mL). The LoD for infectious virus was estimated to be 1 plaque-forming unit/mL, and for RNA to be 232 copies/mL (95% CI 163–302 copies/mL). The assay correctly identified five different Ebola viruses, Yambuku-Mayinga, Makona-C07, Yambuku-Ecran, Gabon-Ilembe, and Kikwit-956210, and correctly excluded all non-EBOV isolates tested. The conditions used by Xpert® Ebola for inactivation of infectious virus reduced EBOV titer by ≥6 logs. Conclusion In summary, we found the Xpert® Ebola Assay to have high analytical sensitivity and specificity for the detection of EBOV in whole blood. It offers ease of use, fast turnaround time, and remote monitoring. The test has an efficient viral inactivation protocol, fulfills inclusivity and exclusivity criteria, and has specimen stability characteristics consistent with the need for decentralized testing. The simplicity of the assay should enable testing in a wide variety of laboratory settings, including remote laboratories that are not capable of performing highly complex nucleic acid amplification tests, and during outbreaks where time to detection is critical. PMID:26562786

  20. A multigear protocol for sampling crayfish assemblages in Gulf of Mexico coastal streams

    Treesearch

    William R. Budnick; William E. Kelso; Susan B. Adams; Michael D. Kaller

    2018-01-01

    Identifying an effective protocol for sampling crayfish in streams that vary in habitat and physical/chemical characteristics has proven problematic. We evaluated an active, combined-gear (backpack electrofishing and dipnetting) sampling protocol in 20 Coastal Plain streams in Louisiana. Using generalized linear models and rarefaction curves, we evaluated environmental...

  1. Protocol for monitoring forest-nesting birds in National Park Service parks

    USGS Publications Warehouse

    Dawson, Deanna K.; Efford, Murray G.

    2013-01-01

    These documents detail the protocol for monitoring forest-nesting birds in National Park Service parks in the National Capital Region Network (NCRN). In the first year of sampling, counts of birds should be made at 384 points on the NCRN spatially randomized grid, developed to sample terrestrial resources. Sampling should begin on or about May 20 and continue into early July; on each day the sampling period begins at sunrise and ends five hours later. Each point should be counted twice, once in the first half of the field season and once in the second half, with visits made by different observers, balancing the within-season coverage of points and their spatial coverage by observers, and allowing observer differences to be tested. Three observers, skilled in identifying birds of the region by sight and sound and with previous experience in conducting timed counts of birds, will be needed for this effort. Observers should be randomly assigned to ‘routes’ consisting of eight points, in close proximity and, ideally, in similar habitat, that can be covered in one morning. Counts are 10 minutes in length, subdivided into four 2.5-min intervals. Within each time interval, new birds (i.e., those not already detected) are recorded as within or beyond 50 m of the point, based on where first detected. Binomial distance methods are used to calculate annual estimates of density for species. The data are also amenable to estimation of abundance and detection probability via the removal method. Generalized linear models can be used to assess between-year changes in density estimates or unadjusted count data. This level of sampling is expected to be sufficient to detect a 50% decline in 10 years for approximately 50 bird species, including 14 of 19 species that are priorities for conservation efforts, if analyses are based on unadjusted count data, and for 30 species (6 priority species) if analyses are based on density estimates. The estimates of required sample sizes are based on the mean number of individuals detected per 10 minutes in available data from surveys in three NCRN parks. Once network-wide data from the first year of sampling are available, this and other aspects of the protocol should be re-assessed, and changes made as desired or necessary before the start of the second field season. Thereafter, changes should not be made to the field methods, and sampling should be conducted annually for at least ten years. NCRN staff should keep apprised of new analytical methods developed for analysis of point-count data.

  2. Development of an integrated laboratory system for the monitoring of cyanotoxins in surface and drinking waters.

    PubMed

    Triantis, Theodoros; Tsimeli, Katerina; Kaloudis, Triantafyllos; Thanassoulias, Nicholas; Lytras, Efthymios; Hiskia, Anastasia

    2010-05-01

    A system of analytical processes has been developed in order to serve as a cost-effective scheme for the monitoring of cyanobacterial toxins on a quantitative basis, in surface and drinking waters. Five cyclic peptide hepatotoxins, microcystin-LR, -RR, -YR, -LA and nodularin were chosen as the target compounds. Two different enzyme-linked immunosorbent assays (ELISA) were validated in order to serve as primary quantitative screening tools. Validation results showed that the ELISA methods are sufficiently specific and sensitive with limits of detection (LODs) around 0.1 microg/L, however, matrix effects should be considered, especially with surface water samples or bacterial mass methanolic extracts. A colorimetric protein phosphatase inhibition assay (PPIA) utilizing protein phosphatase 2A and p-nitrophenyl phosphate as substrate, was applied in microplate format in order to serve as a quantitative screening method for the detection of the toxic activity associated with cyclic peptide hepatotoxins, at concentration levels >0.2 microg/L of MC-LR equivalents. A fast HPLC/PDA method has been developed for the determination of microcystins, by using a short, 50mm C18 column, with 1.8 microm particle size. Using this method a 10-fold reduction of sample run time was achieved and sufficient separation of microcystins was accomplished in less than 3 min. Finally, the analytical system includes an LC/MS/MS method that was developed for the determination of the 5 target compounds after SPE extraction. The method achieves extremely low limits of detection (<0.02 microg/L), in both surface and drinking waters and it is used for identification and verification purposes as well as for determinations at the ppt level. An analytical protocol that includes the above methods has been designed and validated through the analysis of a number of real samples. Copyright 2009 Elsevier Ltd. All rights reserved.

  3. Quantitative evaluation of analyte transport on microfluidic paper-based analytical devices (μPADs).

    PubMed

    Ota, Riki; Yamada, Kentaro; Suzuki, Koji; Citterio, Daniel

    2018-02-07

    The transport efficiency during capillary flow-driven sample transport on microfluidic paper-based analytical devices (μPADs) made from filter paper has been investigated for a selection of model analytes (Ni 2+ , Zn 2+ , Cu 2+ , PO 4 3- , bovine serum albumin, sulforhodamine B, amaranth) representing metal cations, complex anions, proteins and anionic molecules. For the first time, the transport of the analytical target compounds rather than the sample liquid, has been quantitatively evaluated by means of colorimetry and absorption spectrometry-based methods. The experiments have revealed that small paperfluidic channel dimensions, additional user operation steps (e.g. control of sample volume, sample dilution, washing step) as well as the introduction of sample liquid wicking areas allow to increase analyte transport efficiency. It is also shown that the interaction of analytes with the negatively charged cellulosic paper substrate surface is strongly influenced by the physico-chemical properties of the model analyte and can in some cases (Cu 2+ ) result in nearly complete analyte depletion during sample transport. The quantitative information gained through these experiments is expected to contribute to the development of more sensitive μPADs.

  4. Orthogonal identification of gunshot residue with complementary detection principles of voltammetry, scanning electron microscopy, and energy-dispersive X-ray spectroscopy: sample, screen, and confirm.

    PubMed

    O'Mahony, Aoife M; Samek, Izabela A; Sattayasamitsathit, Sirilak; Wang, Joseph

    2014-08-19

    Field-deployable voltammetric screening coupled with complementary laboratory-based analysis to confirm the presence of gunshot residue (GSR) from the hands of a subject who has handled, loaded, or discharged a firearm is described. This protocol implements the orthogonal identification of the presence of GSR utilizing square-wave stripping voltammetry (SWSV) as a rapid screening tool along with scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX) to confirm the presence of the characteristic morphology and metal composition of GSR particles. This is achieved through the judicious modification of the working electrode of a carbon screen-printed electrode (CSPE) with carbon tape (used in SEM analysis) to fix and retain a sample. A comparison between a subject who has handled and loaded a firearm and a subject who has had no contact with GSR shows the significant variations in voltammetric signals and the presence or absence of GSR-consistent particles and constituent metals. This initial electrochemical screening has no effect on the integrity of the metallic particles, and SEM/EDX analysis conducted prior to and postvoltammetry show no differences in analytical output. The carbon tape is instrumental in retaining the GSR sample after electrochemical analysis, supported by comparison with orthogonal detection at a bare CSPE. This protocol shows great promise as a two-tier detection system for the presence of GSR from the hands of a subject, whereby initial screening can be conducted rapidly onsite by minimally trained operators; confirmation can follow at the same substrate to substantiate the voltammetric results.

  5. Development of an enrichment method for endogenous phosphopeptide characterization in human serum.

    PubMed

    La Barbera, Giorgia; Capriotti, Anna Laura; Cavaliere, Chiara; Ferraris, Francesca; Laus, Michele; Piovesana, Susy; Sparnacci, Katia; Laganà, Aldo

    2018-01-01

    The work describes the development of an enrichment method for the analysis of endogenous phosphopeptides in serum. Endogenous peptides can play significant biological roles, and some of them could be exploited as future biomarkers. In this context, blood is one of the most useful biofluids for screening, but a systematic investigation of the endogenous peptides, especially phosphorylated ones, is still lacking, mainly due to the lack of suitable analytical methods. Thus, in this paper, different phosphopeptide enrichment strategies were pursued, based either on metal oxide affinity chromatography (MOAC, in the form of commercial TiO 2 spin columns or magnetic graphitized carbon black-TiO 2 composite), or on immobilized metal ion affinity chromatography (IMAC, in the form of Ti 4+ -IMAC magnetic material or commercial Fe 3+ -IMAC spin columns). While MOAC strategies proved completely unsuccessful, probably due to interfering phospholipids displacing phosphopeptides, the IMAC materials performed very well. Different sample preparation strategies were tested, comprising direct dilution with the loading buffer, organic solvent precipitation, and lipid removal from the matrix, as well as the addition of phosphatase inhibitors during sample handling for maximized endogenous phosphopeptide enrichment. All data were acquired by a shotgun peptidomics approach, in which peptide samples were separated by reversed-phase nanoHPLC hyphenated with high-resolution tandem mass spectrometry. The devised method allowed the identification of 176 endogenous phosphopeptides in fresh serum added with inhibitors by the direct dilution protocol and the Ti 4+ -IMAC magnetic material enrichment, but good results could also be obtained from the commercial Fe 3+ -IMAC spin column adapted to the batch enrichment protocol.

  6. Optimal molecular profiling of tissue and tissue components: defining the best processing and microdissection methods for biomedical applications.

    PubMed

    Bova, G Steven; Eltoum, Isam A; Kiernan, John A; Siegal, Gene P; Frost, Andra R; Best, Carolyn J M; Gillespie, John W; Emmert-Buck, Michael R

    2005-01-01

    Isolation of well-preserved pure cell populations is a prerequisite for sound studies of the molecular basis of pancreatic malignancy and other biological phenomena. This chapter reviews current methods for obtaining anatomically specific signals from molecules isolated from tissues, a basic requirement for productive linking of phenotype and genotype. The quality of samples isolated from tissue and used for molecular analysis is often glossed-over or omitted from publications, making interpretation and replication of data difficult or impossible. Fortunately, recently developed techniques allow life scientists to better document and control the quality of samples used for a given assay, creating a foundation for improvement in this area. Tissue processing for molecular studies usually involves some or all of the following steps: tissue collection, gross dissection/identification, fixation, processing/embedding, storage/archiving, sectioning, staining, microdissection/annotation, and pure analyte labeling/identification. High-quality tissue microdissection does not necessarily mean high-quality samples to analyze. The quality of biomaterials obtained for analysis is highly dependent on steps upstream and downstream from tissue microdissection. We provide protocols for each of these steps, and encourage you to improve upon these. It is worth the effort of every laboratory to optimize and document its technique at each stage of the process, and we provide a starting point for those willing to spend the time to optimize. In our view, poor documentation of tissue and cell type of origin and the use of nonoptimized protocols is a source of inefficiency in current life science research. Even incremental improvement in this area will increase productivity significantly.

  7. Detection of circulating microparticles by flow cytometry: influence of centrifugation, filtration of buffer, and freezing

    PubMed Central

    Dey-Hazra, Emily; Hertel, Barbara; Kirsch, Torsten; Woywodt, Alexander; Lovric, Svjetlana; Haller, Hermann; Haubitz, Marion; Erdbruegger, Uta

    2010-01-01

    The clinical importance of microparticles resulting from vesiculation of platelets and other blood cells is increasingly recognized, although no standardized method exists for their measurement. Only a few studies have examined the analytical and preanalytical steps and variables affecting microparticle detection. We focused our analysis on microparticle detection by flow cytometry. The goal of our study was to analyze the effects of different centrifugation protocols looking at different durations of high and low centrifugation speeds. We also analyzed the effect of filtration of buffer and long-term freezing on microparticle quantification, as well as the role of Annexin V in the detection of microparticles. Absolute and platelet-derived microparticles were 10- to 15-fold higher using initial lower centrifugation speeds at 1500 × g compared with protocols using centrifugation speeds at 5000 × g (P < 0.01). A clear separation between true events and background noise was only achieved using higher centrifugation speeds. Filtration of buffer with a 0.2 μm filter reduced a significant amount of background noise. Storing samples for microparticle detection at −80°C decreased microparticle levels at days 28, 42, and 56 (P < 0.05 for all comparisons with fresh samples). We believe that staining with Annexin V is necessary to distinguish true events from cell debris or precipitates. Buffers should be filtered and fresh samples should be analyzed, or storage periods will have to be standardized. Higher centrifugation speeds should be used to minimize contamination by smaller size platelets. PMID:21191433

  8. A Delayed Neutron Counting System for the Analysis of Special Nuclear Materials

    NASA Astrophysics Data System (ADS)

    Sellers, Madison Theresa

    Nuclear forensic analysis is a modem science that uses numerous analytical techniques to identify and attribute nuclear materials in the event of a nuclear explosion, radiological terrorist attack or the interception of illicit nuclear material smuggling. The Canadian Department of National Defence has participated in recent international exercises that have highlighted the Nation's requirement to develop nuclear forensics expertise, protocol and capabilities, specifically pertaining to the analysis of special nuclear materials (SNM). A delayed neutron counting (DNC) system has been designed and established at the Royal Military College of Canada (RMC) to enhance the Government's SNM analysis capabilities. This analytical technique complements those already at RMC by providing a rapid and non-destructive method for the analysis of the fissile isotopes of both uranium (U) and plutonium (Pu). The SLOWPOKE-2 reactor at RMC produces a predominately thermal neutron flux. These neutrons induce fission in the SNM isotopes 233U, 235U and 239Pu releasing prompt fast neutrons, energy and radioactive fission fragments. Some of these fission fragments undergo beta - decay and subsequently emit neutrons, which can be recorded by an array of sensitive 3He detectors. The significant time period between the fission process and the release of these neutrons results in their identification as 'delayed neutrons'. The recorded neutron spectrum varies with time and the count rate curve is unique to each fissile isotope. In-house software, developed by this project, can analyze this delayed neutron curve and provides the fissile mass in the sample. Extensive characterization of the DNC system has been performed with natural U samples with 235 U content ranging from 2--7 microg. The system efficiency and dead time behaviour determined by the natural uranium sample analyses were validated by depleted uranium samples with similar quantities of 235 U resulting in a typical relative error of 3.6%. The system has accurately determined 235U content over three orders of magnitude with 235U amounts as low as 10 ng. The results have also been proven to be independent of small variations in total analyte volume and geometry, indicating that it is an ideal technique for the analysis of samples containing SNM in a variety of different matrices. The Analytical Sciences Group at RMC plans to continue DNC system development to include 233U and 239pu analysis and mixtures of SNM isotopes. Keywords: delayed neutron counting, special nuclear materials, nuclear forensics.

  9. Immuno Nanosensor for the Ultrasensitive Naked Eye Detection of Tuberculosis.

    PubMed

    Mohd Bakhori, Noremylia; Yusof, Nor Azah; Abdullah, Jaafar; Wasoh, Helmi; Md Noor, Siti Suraiya; Ahmad Raston, Nurul Hanun; Mohammad, Faruq

    2018-06-14

    In the present study, a beneficial approach for the ultrasensitive and affordable naked eye detection and diagnosis of tuberculosis (TB) by utilizing plasmonic enzyme-linked immunosorbent assay (ELISA) via antibody-antigen interaction was studied. Here, the biocatalytic cycle of the intracellular enzymes links to the formation and successive growth of the gold nanoparticles (GNPs) for ultrasensitive detection. The formation of different colored solutions by the plasmonic nanoparticles in the presence of enzyme labels links directly to the existence or non-existence of the TB analytes in the sample solutions. For disease detection, the adapted protocol is based mainly on the conventional ELISA procedure that involves catalase-labeled antibodies, i.e., the enzymes consume hydrogen peroxide and further produce GNPs with the addition of gold (III) chloride. The amount of hydrogen peroxide remaining in the solution determines whether the GNPs solution is to be formed in the color blue or the color red, as it serves as a confirmation for the naked eye detection of TB analytes. However, the conventional ELISA method only shows tonal colors that need a high concentration of analyte to achieve high confidence levels for naked eye detection. Also, in this research, we proposed the incorporation of protein biomarker, Mycobacterium tuberculosis ESAT-6-like protein esxB (CFP-10), as a means of TB detection using plasmonic ELISA. With the use of this technique, the CFP-10 detection limit can be lowered to 0.01 µg/mL by the naked eye. Further, our developed technique was successfully tested and confirmed with sputum samples from patients diagnosed with positive TB, thereby providing enough evidence for the utilization of our technique in the early diagnosis of TB disease.

  10. The potential of using laser ablation inductively coupled plasma time of flight mass spectrometry (LA-ICP-TOF-MS) in the forensic analysis of micro debris.

    PubMed

    Scadding, Cameron J; Watling, R John; Thomas, Allen G

    2005-08-15

    The majority of crimes result in the generation of some form of physical evidence, which is available for collection by crime scene investigators or police. However, this debris is often limited in amount as modern criminals become more aware of its potential value to forensic scientists. The requirement to obtain robust evidence from increasingly smaller sized samples has required refinement and modification of old analytical techniques and the development of new ones. This paper describes a new method for the analysis of oxy-acetylene debris, left behind at a crime scene, and the establishment of its co-provenance with single particles of equivalent debris found on the clothing of persons of interest (POI). The ability to rapidly determine and match the elemental distribution patterns of debris collected from crime scenes to those recovered from persons of interest is essential in ensuring successful prosecution. Traditionally, relatively large amounts of sample (up to several milligrams) have been required to obtain a reliable elemental fingerprint of this type of material [R.J. Walting , B.F. Lynch, D. Herring, J. Anal. At. Spectrom. 12 (1997) 195]. However, this quantity of material is unlikely to be recovered from a POI. This paper describes the development and application of laser ablation inductively coupled plasma time of flight mass spectrometry (LA-ICP-TOF-MS), as an analytical protocol, which can be applied more appropriately to the analysis of micro-debris than conventional quadrupole based mass spectrometry. The resulting data, for debris as small as 70mum in diameter, was unambiguously matched between a single spherule recovered from a POI and a spherule recovered from the scene of crime, in an analytical procedure taking less than 5min.

  11. Variability in baseline laboratory measurements of the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil).

    PubMed

    Ladwig, R; Vigo, A; Fedeli, L M G; Chambless, L E; Bensenor, I; Schmidt, M I; Vidigal, P G; Castilhos, C D; Duncan, B B

    2016-08-01

    Multi-center epidemiological studies must ascertain that their measurements are accurate and reliable. For laboratory measurements, reliability can be assessed through investigation of reproducibility of measurements in the same individual. In this paper, we present results from the quality control analysis of the baseline laboratory measurements from the ELSA-Brasil study. The study enrolled 15,105 civil servants at 6 research centers in 3 regions of Brazil between 2008-2010, with multiple biochemical analytes being measured at a central laboratory. Quality control was ascertained through standard laboratory evaluation of intra- and inter-assay variability and test-retest analysis in a subset of randomly chosen participants. An additional sample of urine or blood was collected from these participants, and these samples were handled in the same manner as the original ones, locally and at the central laboratory. Reliability was assessed with the intraclass correlation coefficient (ICC), estimated through a random effects model. Coefficients of variation (CV) and Bland-Altman plots were additionally used to assess measurement variability. Laboratory intra and inter-assay CVs varied from 0.86% to 7.77%. From test-retest analyses, the ICCs were high for the majority of the analytes. Notably lower ICCs were observed for serum sodium (ICC=0.50; 95%CI=0.31-0.65) and serum potassium (ICC=0.73; 95%CI=0.60-0.83), due to the small biological range of these analytes. The CVs ranged from 1 to 14%. The Bland-Altman plots confirmed these results. The quality control analyses showed that the collection, processing and measurement protocols utilized in the ELSA-Brasil produced reliable biochemical measurements.

  12. Post-analytical stability of 23 common chemistry and immunochemistry analytes in incurred samples.

    PubMed

    Nielsen, Betina Klint; Frederiksen, Tina; Friis-Hansen, Lennart; Larsen, Pia Bükmann

    2017-12-01

    Storage of blood samples after centrifugation, decapping and initial sampling allows ordering of additional blood tests. The pre-analytic stability of biochemistry and immunochemistry analytes has been studied in detail, but little is known about the post-analytical stability in incurred samples. We examined the stability of 23 routine analytes on the Dimension Vista® (Siemens Healthineers, Denmark): 42-60 routine samples in lithium-heparin gel tubes (Vacutainer, BD, USA) were centrifuged at 3000×g for 10min. Immediately after centrifugation, initial concentration of analytes were measured in duplicate (t=0). The tubes were stored decapped at room temperature and re-analyzed after 2, 4, 6, 8 and 10h in singletons. The concentration from reanalysis were normalized to initial concentration (t=0). Internal acceptance criteria for bias and total error were used to determine stability of each analyte. Additionally, evaporation from the decapped blood collection tubes and the residual platelet count in the plasma after centrifugation were quantified. We report a post-analytical stability of most routine analytes of ≥8h and do therefore - with few exceptions - suggest a standard 8hour-time limit for reordering and reanalysis of analytes in incurred samples. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Variability of measurements of sweat sodium using the regional absorbent-patch method.

    PubMed

    Dziedzic, Christine E; Ross, Megan L; Slater, Gary J; Burke, Louise M

    2014-09-01

    There is interest in including recommendations for the replacement of the sodium lost in sweat in individualized hydration plans for athletes. Although the regional absorbent-patch method provides a practical approach to measuring sweat sodium losses in field conditions, there is a need to understand the variability of estimates associated with this technique. Sweat samples were collected from the forearms, chest, scapula, and thigh of 12 cyclists during 2 standardized cycling time trials in the heat and 2 in temperate conditions. Single measure analysis of sodium concentration was conducted immediately by ion-selective electrodes (ISE). A subset of 30 samples was frozen for reanalysis of sodium concentration using ISE, flame photometry (FP), and conductivity (SC). Sweat samples collected in hot conditions produced higher sweat sodium concentrations than those from the temperate environment (P = .0032). A significant difference (P = .0048) in estimates of sweat sodium concentration was evident when calculated from the forearm average (mean ± 95% CL; 64 ± 12 mmol/L) compared with using a 4-site equation (70 ± 12 mmol/L). There was a high correlation between the values produced using different analytical techniques (r2 = .95), but mean values were different between treatments (frozen FP, frozen SC > immediate ISE > frozen ISE; P < .0001). Whole-body sweat sodium concentration estimates differed depending on the number of sites included in the calculation. Environmental testing conditions should be considered in the interpretation of results. The impact of sample freezing and subsequent analytical technique was small but statistically significant. Nevertheless, when undertaken using a standardized protocol, the regional absorbent-patch method appears to be a relatively robust field test.

  14. Development of "one-pot" method for multi-class compounds in porcine formula feed by multi-function impurity adsorption cleaning followed ultra-performance liquid chromatography-tandem mass spectrometry detection.

    PubMed

    Wang, Peilong; Wang, Xiao; Zhang, Wei; Su, Xiaoou

    2014-02-01

    A novel and efficient determination method for multi-class compounds including β-agonists, sedatives, nitro-imidazoles and aflatoxins in porcine formula feed based on a fast "one-pot" extraction/multifunction impurity adsorption (MFIA) clean-up procedure has been developed. 23 target analytes belonging to four different class compounds could be determined simultaneously in a single run. Conditions for "one-pot" extraction were studied in detail. Under the optimized conditions, the multi-class compounds in porcine formula feed samples were extracted and purified with methanol contained ammonia and absorbents by one step. The compounds in extracts were purified by using multi types of absorbent based on MFIA in one pot. The multi-walled carbon nanotubes were employed to improved clean-up efficiency. Shield BEH C18 column was used to separate 23 target analytes, followed by tandem mass spectrometry (MS/MS) detection using an electro-spray ionization source in positive mode. Recovery studies were done at three fortification levels. Overall average recoveries of target compounds in porcine formula feed at each levels were >51.6% based on matrix fortified calibration with coefficients of variation from 2.7% to 13.2% (n=6). The limit of determination (LOD) of these compounds in porcine formula feed sample matrix was <5.0 μg/kg. This method was successfully applied in screening and confirmation of target drugs in >30 porcine formula feed samples. It was demonstrated that the integration of the MFIA protocol with the MS/MS instrument could serve as a valuable strategy for rapid screening and reliable confirmatory analysis of multi-class compounds in real samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Multi-element RIMS Analysis of Genesis Solar Wind Collectors

    NASA Astrophysics Data System (ADS)

    Veryovkin, I. V.; Tripa, C. E.; Zinovev, A. V.; King, B. V.; Pellin, M. J.; Burnett, D. S.

    2009-12-01

    The samples of Solar Wind (SW) delivered by the NASA Genesis mission, present significant challenges for surface analytical techniques, in part due to severe terrestrial contamination of the samples on reentry, in part due to the ultra-shallow and diffused ion implants in the SW collector materials. We are performing measurements of metallic elements in the Genesis collectors using Resonance Ionization Mass Spectrometry (RIMS), an ultra-sensitive analytical method capable of detecting SW in samples with lateral dimensions of only a few mm and at concentrations from above one ppm to below one ppt. Since our last report at 2008 AGU Fall Meeting, we have (a) developed and tested new resonance ionization schemes permitting simultaneous measurements of up to three (Ca, Cr, and Mg) elements, and (b) improved reproducibility and accuracy of our RIMS analyses for SW-like samples (i.e. shallow ion implants) by developing and implementing an optimized set of new analytical protocols. This is important since the quality of scientific results from the Genesis mission critically depends on the accuracy of analytical techniques. In this work, we report on simultaneous RIMS measurements of Ca and Cr performed on two silicon SW collector samples, (#60179 and #60476). First, we have conducted test experiments with 3×1013 at/cm2 52Cr and 44Ca implants in silicon to evaluate the accuracy of our quantitative analyses. Implant fluencies were measured by RIMS to be 2.73×1013 and 2.71×1013 at/cm2 for 52Cr and 44Ca, respectively, which corresponds to an accuracy of ≈10%. Using the same implanted wafer as a reference, we conducted RIMS analyses of the Genesis samples: 3 spots on #60179 and 4 spots on #60476. The elemental SW fluencies expected for Cr and Ca are 2.95×1010 and 1.33×1011 at/cm2 , respectively. Our measurements of 52Cr yielded 3.0±0.6×1011 at/cm2 and 5.1±4.1×1010 at/cm2 for #60179 and #60476, respectively. For 40Ca, SW fluencies of 1.39±0.70×1011 at/cm2 in #60179 and 3.6±2.5×1013 at/cm2 in #60476 were measured. Thus, only one element in each sample showed reasonable agreement with the expected values, Ca in #60179 and Cr in #60476. However the cleaning procedures applied to these samples were different: #60179 was only Megasonicated in ultra-pure water, while #60476 was subjected to longer Megasonication and an RCA cleaning procedure involving multiple rinsing steps with acid solutions. It is apparent that the surface contamination and cleaning procedures influenced the results of our measurements. We will present these experimental results and discuss procedures - including improved sample cleaning, dual-beam high resolution sputter depth profiling from front and back sides of the sample, and modeling of near-surface impurity transport - aimed at improving the accuracy of determination of elemental abundances by ion sputtering based analytical methods. This work is supported by NASA through a grant NNH08AH761 and by UChicago Argonne, LLC, under contract No. DE-AC02-06CH11357.

  16. Versatile microanalytical system with porous polypropylene capillary membrane for calibration gas generation and trace gaseous pollutants sampling applied to the analysis of formaldehyde, formic acid, acetic acid and ammonia in outdoor air.

    PubMed

    Coelho, Lúcia H G; Melchert, Wanessa R; Rocha, Flavio R; Rocha, Fábio R P; Gutz, Ivano G R

    2010-11-15

    The analytical determination of atmospheric pollutants still presents challenges due to the low-level concentrations (frequently in the μg m(-3) range) and their variations with sampling site and time. In this work, a capillary membrane diffusion scrubber (CMDS) was scaled down to match with capillary electrophoresis (CE), a quick separation technique that requires nothing more than some nanoliters of sample and, when combined with capacitively coupled contactless conductometric detection (C(4)D), is particularly favorable for ionic species that do not absorb in the UV-vis region, like the target analytes formaldehyde, formic acid, acetic acid and ammonium. The CMDS was coaxially assembled inside a PTFE tube and fed with acceptor phase (deionized water for species with a high Henry's constant such as formaldehyde and carboxylic acids, or acidic solution for ammonia sampling with equilibrium displacement to the non-volatile ammonium ion) at a low flow rate (8.3 nL s(-1)), while the sample was aspirated through the annular gap of the concentric tubes at 2.5 mL s(-1). A second unit, in all similar to the CMDS, was operated as a capillary membrane diffusion emitter (CMDE), generating a gas flow with know concentrations of ammonia for the evaluation of the CMDS. The fluids of the system were driven with inexpensive aquarium air pumps, and the collected samples were stored in vials cooled by a Peltier element. Complete protocols were developed for the analysis, in air, of NH(3), CH(3)COOH, HCOOH and, with a derivatization setup, CH(2)O, by associating the CMDS collection with the determination by CE-C(4)D. The ammonia concentrations obtained by electrophoresis were checked against the reference spectrophotometric method based on Berthelot's reaction. Sensitivity enhancements of this reference method were achieved by using a modified Berthelot reaction, solenoid micro-pumps for liquid propulsion and a long optical path cell based on a liquid core waveguide (LCW). All techniques and methods of this work are in line with the green analytical chemistry trends. Copyright © 2010 Elsevier B.V. All rights reserved.

  17. Direct lead isotope analysis in Hg-rich sulfides by LA-MC-ICP-MS with a gas exchange device and matrix-matched calibration.

    PubMed

    Zhang, Wen; Hu, Zhaochu; Günther, Detlef; Liu, Yongsheng; Ling, Wenli; Zong, Keqing; Chen, Haihong; Gao, Shan

    2016-12-15

    In situ Pb isotope data of sulfide samples measured by LA-MC-ICP-MS provide valuable geochemical information for studies of the origin and evolution of ore deposits. However, the severe isobaric interference of 204 Hg on 204 Pb and the lack of matrix-matched sulfide reference materials limit the precision of Pb isotopic analyses for Hg-rich sulfides. In this study, we observe that Hg forms vapor and can be completely removed from sample aerosol particles produced by laser ablation using a gas exchange device. Additionally, this device does not influence the signal intensities of Pb isotopes. The within-run precision, the external reproducibility and the analytical accuracy are significantly improved for the Hg-rich sulfide samples using this mercury-vapor-removing device. Matrix effects are observed when using silicate glass reference materials as the external standards to assess the relationship of mass fractionation factors between Tl and Pb in sulfide samples, resulting in a maximum deviation of ∼0.20% for 20x Pb/ 204 Pb. Matrix-matched reference materials are therefore required for the highly precise and accurate Pb isotope analyses of sulfide samples. We investigated two sulfide samples, MASS-1 (the Unites States Geological Survey reference materials) and Sph-HYLM (a natural sphalerite), as potential candidates. Repeated analyses of the two proposed sulfide reference materials by LA-MC-ICP-MS yield good external reproducibility of <0.04% (RSD, k = 2) for 20x Pb/ 206 Pb and <0.06% (RSD, k = 2) for 20x Pb/ 204 Pb with the exception of 20x Pb/ 204 Pb in MASS-1, which provided an external reproducibility of 0.24% (RSD, k = 2). Because the concentration of Pb in MASS-1 (76 μg g -1 ) is ∼5.2 times lower than that in Sph-HYLM (394 ± 264 μg g -1 ). The in situ analytical results of MASS-1 and Sph-HYLM are consistent with the values obtained by solution MC-ICP-MS, demonstrating the reliability and robustness of our analytical protocol. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Detection of multiple steroidal compounds in synthetic urine using comprehensive gas chromatography-mass spectrometry (GC×GC-MS) combined with a molecularly imprinted polymer clean-up protocol.

    PubMed

    Zulfiqar, Adnan; Morgan, Geraint; Turner, Nicholas W

    2014-10-07

    A method capable of screening for multiple steroids in urine has been developed, using a series of twelve structurally similar, and commercially relevant compounds as target analytes. A molecularly imprinted solid phase extraction clean-up step was used to make the sample suitable for injection onto a GC×GC-MS setup. Significant improvements compared to a commercially available C-18 material were observed. Each individual steroid was able to be separated and identified, using both the retention profile and diagnostic fragmentation ion monitoring abilities of the comprehensive chromatographic-mass spectrometry method. Effective LODs of between 11.7 and 27.0 pg were calculated for individual steroids, effectively equivalent to concentration levels of between 0.234 and 0.540 ng mL(-1) in urine, while the application of multiple screen was demonstrated using a 10 ng mL(-1) mixed sample. The nature of this study also removes the need for sample derivitisation which speeds up the screening process.

  19. Global metabolic profiling procedures for urine using UPLC-MS.

    PubMed

    Want, Elizabeth J; Wilson, Ian D; Gika, Helen; Theodoridis, Georgios; Plumb, Robert S; Shockcor, John; Holmes, Elaine; Nicholson, Jeremy K

    2010-06-01

    The production of 'global' metabolite profiles involves measuring low molecular-weight metabolites (<1 kDa) in complex biofluids/tissues to study perturbations in response to physiological challenges, toxic insults or disease processes. Information-rich analytical platforms, such as mass spectrometry (MS), are needed. Here we describe the application of ultra-performance liquid chromatography-MS (UPLC-MS) to urinary metabolite profiling, including sample preparation, stability/storage and the selection of chromatographic conditions that balance metabolome coverage, chromatographic resolution and throughput. We discuss quality control and metabolite identification, as well as provide details of multivariate data analysis approaches for analyzing such MS data. Using this protocol, the analysis of a sample set in 96-well plate format, would take ca. 30 h, including 1 h for system setup, 1-2 h for sample preparation, 24 h for UPLC-MS analysis and 1-2 h for initial data processing. The use of UPLC-MS for metabolic profiling in this way is not faster than the conventional HPLC-based methods but, because of improved chromatographic performance, provides superior metabolome coverage.

  20. A distance limited method for sampling downed coarse woody debris

    Treesearch

    Jeffrey H. Gove; Mark J. Ducey; Harry T. Valentine; Michael S. Williams

    2012-01-01

    A new sampling method for down coarse woody debris is proposed based on limiting the perpendicular distance from individual pieces to a randomly chosen sample point. Two approaches are presented that allow different protocols to be used to determine field measurements; estimators for each protocol are also developed. Both protocols are compared via simulation against...

  1. Pre-Mission Input Requirements to Enable Successful Sample Collection by A Remote Field/EVA Team

    NASA Technical Reports Server (NTRS)

    Cohen, B. A.; Lim, D. S. S.; Young, K. E.; Brunner, A.; Elphic, R. E.; Horne, A.; Kerrigan, M. C.; Osinski, G. R.; Skok, J. R.; Squyres, S. W.; hide

    2016-01-01

    The FINESSE (Field Investigations to Enable Solar System Science and Exploration) team, part of the Solar System Exploration Virtual Institute (SSERVI), is a field-based research program aimed at generating strategic knowledge in preparation for human and robotic exploration of the Moon, near-Earth asteroids, Phobos and Deimos, and beyond. In contract to other technology-driven NASA analog studies, The FINESSE WCIS activity is science-focused and, moreover, is sampling-focused with the explicit intent to return the best samples for geochronology studies in the laboratory. We used the FINESSE field excursion to the West Clearwater Lake Impact structure (WCIS) as an opportunity to test factors related to sampling decisions. We examined the in situ sample characterization and real-time decision-making process of the astronauts, with a guiding hypothesis that pre-mission training that included detailed background information on the analytical fate of a sample would better enable future astronauts to select samples that would best meet science requirements. We conducted three tests of this hypothesis over several days in the field. Our investigation was designed to document processes, tools and procedures for crew sampling of planetary targets. This was not meant to be a blind, controlled test of crew efficacy, but rather an effort to explicitly recognize the relevant variables that enter into sampling protocol and to be able to develop recommendations for crew and backroom training in future endeavors.

  2. Two alternative DNA extraction methods to improve the detection of Mycobacterium-tuberculosis-complex members in cattle and red deer tissue samples.

    PubMed

    Fell, Shari; Bröckl, Stephanie; Büttner, Mathias; Rettinger, Anna; Zimmermann, Pia; Straubinger, Reinhard K

    2016-09-15

    Bovine tuberculosis (bTB), which is caused by Mycobacterium bovis and M. caprae, is a notifiable animal disease in Germany. Diagnostic procedure is based on a prescribed protocol that is published in the framework of German bTB legislation. In this protocol small sample volumes are used for DNA extraction followed by real-time PCR analyses. As mycobacteria tend to concentrate in granuloma and the infected tissue in early stages of infection does not necessarily show any visible lesions, it is likely that DNA extraction from only small tissue samples (20-40 mg) of a randomly chosen spot from the organ and following PCR testing may result in false negative results. In this study two DNA extraction methods were developed to process larger sample volumes to increase the detection sensitivity of mycobacterial DNA in animal tissue. The first extraction method is based on magnetic capture, in which specific capture oligonucleotides were utilized. These nucleotides are linked to magnetic particles and capture Mycobacterium-tuberculosis-complex (MTC) DNA released from 10 to 15 g of tissue material. In a second approach remaining sediments from the magnetic capture protocol were further processed with a less complex extraction protocol that can be used in daily routine diagnostics. A total number of 100 tissue samples from 34 cattle (n = 74) and 18 red deer (n = 26) were analyzed with the developed protocols and results were compared to the prescribed protocol. All three extraction methods yield reliable results by the real-time PCR analysis. The use of larger sample volume led to a sensitivity increase of DNA detection which was shown by the decrease of Ct-values. Furthermore five samples which were tested negative or questionable by the official extraction protocol were detected positive by real time PCR when the alternative extraction methods were used. By calculating the kappa index, the three extraction protocols resulted in a moderate (0.52; protocol 1 vs 3) to almost perfect agreement (1.00; red deer sample testing with all protocols). Both new methods yielded increased detection rates for MTC DNA detection in large sample volumes and consequently improve the official diagnostic protocol.

  3. Method of and apparatus for determining the similarity of a biological analyte from a model constructed from known biological fluids

    DOEpatents

    Robinson, Mark R.; Ward, Kenneth J.; Eaton, Robert P.; Haaland, David M.

    1990-01-01

    The characteristics of a biological fluid sample having an analyte are determined from a model constructed from plural known biological fluid samples. The model is a function of the concentration of materials in the known fluid samples as a function of absorption of wideband infrared energy. The wideband infrared energy is coupled to the analyte containing sample so there is differential absorption of the infrared energy as a function of the wavelength of the wideband infrared energy incident on the analyte containing sample. The differential absorption causes intensity variations of the infrared energy incident on the analyte containing sample as a function of sample wavelength of the energy, and concentration of the unknown analyte is determined from the thus-derived intensity variations of the infrared energy as a function of wavelength from the model absorption versus wavelength function.

  4. Hindering the illegal trade in dog and cat furs through a DNA-based protocol for species identification.

    PubMed

    Garofalo, Luisa; Mariacher, Alessia; Fanelli, Rita; Fico, Rosario; Lorenzini, Rita

    2018-01-01

    In Western countries dogs and cats are the most popular pets, and people are increasingly opposed to their rearing for the fur industry. In 2007, a Regulation of the European Union (EU) banned the use and trade of dog and cat furs, but an official analytical protocol to identify them as source species was not provided, and violations of law are still frequent in all Member States. In this paper we report on the development and validation of a simple and affordable DNA method for species detection in furs to use as an effective tool to combat illegal trade in fur products. A set of mitochondrial primers was designed for amplification of partial cytochrome b, control region and ND1 gene in highly degraded samples, like furs and pelts. Our amplification workflow involved the use of a non-specific primer pair to perform a first test to identify the species through sequencing, then the application of species-specific primer pairs to use in singleplex end-point PCRs as confirmation tests. The advantage of this two-step procedure is twofold: on the one hand it minimises the possibility of negative test results from degraded samples, since failure of amplification with a first set of primers can be offset by successful amplification of the second, and on the other it adds confidence and reliability to final authentication of species. All designed primers were validated on a reference collection of tissue samples, obtaining solid results in terms of specificity, sensitivity, repeatability and reproducibility. Application of the protocol on real caseworks from seized furs yielded successful results also from old and dyed furs, suggesting that age and chemical staining do not necessarily affect positive amplifications. Major pros of this approach are: (1) sensitive and informative primer sets for detection of species; (2) short PCR amplicons for the analysis of poor quality DNA; (3) binding primers that avoid contamination from human DNA; (4) user-friendly protocol for any laboratory equipped for analysis of low-copy-number DNA. Our molecular procedure proved to be a good starting point for enforcing the EU Regulation against dog and cat fur trade in forensic contexts where source attribution is essential to the assignment of responsibilities.

  5. Continuous-flow centrifugation to collect suspended sediment for chemical analysis

    USGS Publications Warehouse

    Conn, Kathleen E.; Dinicola, Richard S.; Black, Robert W.; Cox, Stephen E.; Sheibley, Richard W.; Foreman, James R.; Senter, Craig A.; Peterson, Norman T.

    2016-12-22

    Recent advances in suspended-sediment monitoring tools and surrogate technologies have greatly improved the ability to quantify suspended-sediment concentrations and to estimate daily, seasonal, and annual suspended-sediment fluxes from rivers to coastal waters. However, little is known about the chemical composition of suspended sediment, and how it may vary spatially between water bodies and temporally within a single system owing to climate, seasonality, land use, and other natural and anthropogenic drivers. Many water-quality contaminants, such as organic and inorganic chemicals, nutrients, and pathogens, preferentially partition in sediment rather than water. Suspended sediment-bound chemical concentrations may be undetected during analysis of unfiltered water samples, owing to small water sample volumes and analytical limitations. Quantification of suspended sediment‑bound chemical concentrations is needed to improve estimates of total chemical concentrations, chemical fluxes, and exposure levels of aquatic organisms and humans in receiving environments. Despite these needs, few studies or monitoring programs measure the chemical composition of suspended sediment, largely owing to the difficulty in consistently obtaining samples of sufficient quality and quantity for laboratory analysis.A field protocol is described here utilizing continuous‑flow centrifugation for the collection of suspended sediment for chemical analysis. The centrifuge used for development of this method is small, lightweight, and portable for the field applications described in this protocol. Project scoping considerations, deployment of equipment and system layout options, and results from various field and laboratory quality control experiments are described. The testing confirmed the applicability of the protocol for the determination of many inorganic and organic chemicals sorbed on suspended sediment, including metals, pesticides, polycyclic aromatic hydrocarbons, and polychlorinated biphenyls. The particle-size distribution of the captured sediment changes to a more fine-grained sample during centrifugation, and the necessity to account for this change when extrapolating chemical concentrations on the centrifuged sediment sample to the environmental water system is discussed.The data produced using this method will help eliminate a data gap of suspended sediment-bound chemical concentrations, and will support management decisions, such as chemical source-control efforts or in-stream restoration activities. When coupled with streamflow and sediment flux data, it will improve estimates of riverine chemical fluxes, and will aid in assessing the importance and impacts of suspended sediment-bound chemicals to downstream freshwater and coastal marine ecosystems.

  6. High precision measurement of silicon in naphthas by ICP-OES using isooctane as diluent.

    PubMed

    Gazulla, M F; Rodrigo, M; Orduña, M; Ventura, M J; Andreu, C

    2017-03-01

    An analytical protocol for the accurate and precise determination of Si in naphthas is presented by using ICP-OES, optimizing from the sample preparation to the measurement conditions, in order to be able to analyze for the first time silicon contents below 100µgkg -1 in a relatively short time thus being used as a control method. In the petrochemical industry, silicon can be present as a contaminant in different petroleum products such as gasoline, ethanol, or naphthas, forming different silicon compounds during the treatment of these products that are irreversibly adsorbed onto catalyst surfaces decreasing its time life. The complex nature of the organic naphtha sample together with the low detection limits needed make the analysis of silicon quite difficult. The aim of this work is to optimize the measurement of silicon in naphthas by ICP-OES introducing as an improvement the use of isooctane as diluent. The set up was carried out by optimizing the measurement conditions (power, nebulizer flow, pump rate, read time, and viewing mode) and the sample preparation (type of diluent, cleaning process, blanks, and studying various dilution ratios depending on the sample characteristics). Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Synthesis of core-shell molecularly imprinted polymer microspheres by precipitation polymerization for the inline molecularly imprinted solid-phase extraction of thiabendazole from citrus fruits and orange juice samples.

    PubMed

    Barahona, Francisco; Turiel, Esther; Cormack, Peter A G; Martín-Esteban, Antonio

    2011-01-01

    In this work, the synthesis of molecularly imprinted polymer microspheres with narrow particle size distributions and core-shell morphology by a two-step precipitation polymerization procedure is described. Polydivinylbenzene (poly DVB-80) core particles were used as seed particles in the production of molecularly imprinted polymer shells by copolymerization of divinylbenzene-80 with methacrylic acid in the presence of thiabendazole (TBZ) and an appropriate porogen. Thereafter, polymer particles were packed into refillable stainless steel HPLC columns used in the development of an inline molecularly imprinted SPE method for the determination of TBZ in citrus fruits and orange juice samples. Under optimized chromatographic conditions, recoveries of TBZ within the range 81.1-106.4%, depending upon the sample, were obtained, with RSDs lower than 10%. This novel method permits the unequivocal determination of TBZ in the samples under study, according to the maximum residue levels allowed within Europe, in less than 20 min and without any need for a clean-up step in the analytical protocol. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Analytical protocol for the sensitive determination of mannitol, sorbitol and glucose containing powders in pharmaceutical workplaces by ion chromatography using a pulsed amperometric detector.

    PubMed

    Butler, Owen; Forder, James; Saunders, John

    2015-03-15

    Workers in the pharmaceutical industry can potentially be exposed to airborne dusts and powders that can contain potent active pharmaceutical ingredients (API). Occupational hygienists and health and safety professionals need to assess and ultimately minimise such inhalation and dermal exposure risks. Containment of dusts at source is the first line of defence but the performance of such technologies needs to be verified, for which purpose the good practice guide: assessing the particulate containment performance of pharmaceutical equipment, produced by the International Society for Pharmaceutical Engineering (ISPE), is a widely used reference document. This guide recommends the use of surrogate powders that can be used to challenge the performance of such containment systems. Materials such as lactose and mannitol are recommended as their physical properties (adhesion, compactability, dustiness, flow characteristics and particle sizes) mimic those of API-containing materials typically handled. Furthermore they are safe materials to use, are available in high purity and can be procured at a reasonable cost. The aim of this work was to develop and validate a sensitive ion-chromatography based analytical procedure for the determination of surrogate powders collected on filter samples so as to meet analytical requirements set out in this ISPE guide. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.

  9. Extending the Kerberos Protocol for Distributed Data as a Service

    DTIC Science & Technology

    2012-09-20

    exported as a UIMA [11] PEAR file for deployment to IBM Content Analytics (ICA). A UIMA PEAR file is a deployable text analytics “pipeline” (analogous...to a web application packaged in a WAR file). ICA is a text analysis and search application that supports UIMA . The key entities targeted by NLP rules...workbench. [Online]. Available: https: //www.ibm.com/developerworks/community/alphaworks/lrw/ [11] Apache UIMA . [Online]. Available: http

  10. Bias and precision of selected analytes reported by the National Atmospheric Deposition Program and National Trends Network, 1984

    USGS Publications Warehouse

    Brooks, M.H.; Schroder, L.J.; Willoughby, T.C.

    1987-01-01

    The U.S. Geological Survey operated a blind audit sample program during 1974 to test the effects of the sample handling and shipping procedures used by the National Atmospheric Deposition Program and National Trends Network on the quality of wet deposition data produced by the combined networks. Blind audit samples, which were dilutions of standard reference water samples, were submitted by network site operators to the central analytical laboratory disguised as actual wet deposition samples. Results from the analyses of blind audit samples were used to calculate estimates of analyte bias associated with all network wet deposition samples analyzed in 1984 and to estimate analyte precision. Concentration differences between double blind samples that were submitted to the central analytical laboratory and separate analyses of aliquots of those blind audit samples that had not undergone network sample handling and shipping were used to calculate analyte masses that apparently were added to each blind audit sample by routine network handling and shipping procedures. These calculated masses indicated statistically significant biases for magnesium, sodium , potassium, chloride, and sulfate. Median calculated masses were 41.4 micrograms (ug) for calcium, 14.9 ug for magnesium, 23.3 ug for sodium, 0.7 ug for potassium, 16.5 ug for chloride and 55.3 ug for sulfate. Analyte precision was estimated using two different sets of replicate measures performed by the central analytical laboratory. Estimated standard deviations were similar to those previously reported. (Author 's abstract)

  11. A Possible Freshness Marker for Royal Jelly: Formation of 5-Hydroxymethyl-2-furaldehyde as a Function of Storage Temperature and Time.

    PubMed

    Ciulu, Marco; Floris, Ignazio; Nurchi, Valeria M; Panzanelli, Angelo; Pilo, Maria I; Spano, Nadia; Sanna, Gavino

    2015-04-29

    In this article we present a study of the variability of the concentration of 5-hydroxymethyl-2-furaldehyde (HMF) in natural royal jelly (RJ) as a function of its storage temperature (-18, 4, and 25 °C) and time (up to 9 months after harvesting). For this work HMF is evaluated using an RP-HPLC method we previously assessed. While all RJ samples stored at 4 and -18 °C always showed levels of HMF under the limit of detection (0.13 mg kg(-1)), samples kept at 25 °C showed an exponential increase in the concentration of HMF as a function of the storage time. This behavior and a number of desirable features of the analytical method used (ease of use in routine laboratories, availability of a complete validation protocol specifically developed for RJ, based on consolidated chemical knowledge) allow us to hypothesize the use of HMF as a possible, reliable freshness marker for RJ.

  12. Deterministic generation of remote entanglement with active quantum feedback

    DOE PAGES

    Martin, Leigh; Motzoi, Felix; Li, Hanhan; ...

    2015-12-10

    We develop and study protocols for deterministic remote entanglement generation using quantum feedback, without relying on an entangling Hamiltonian. In order to formulate the most effective experimentally feasible protocol, we introduce the notion of average-sense locally optimal feedback protocols, which do not require real-time quantum state estimation, a difficult component of real-time quantum feedback control. We use this notion of optimality to construct two protocols that can deterministically create maximal entanglement: a semiclassical feedback protocol for low-efficiency measurements and a quantum feedback protocol for high-efficiency measurements. The latter reduces to direct feedback in the continuous-time limit, whose dynamics can bemore » modeled by a Wiseman-Milburn feedback master equation, which yields an analytic solution in the limit of unit measurement efficiency. Our formalism can smoothly interpolate between continuous-time and discrete-time descriptions of feedback dynamics and we exploit this feature to derive a superior hybrid protocol for arbitrary nonunit measurement efficiency that switches between quantum and semiclassical protocols. Lastly, we show using simulations incorporating experimental imperfections that deterministic entanglement of remote superconducting qubits may be achieved with current technology using the continuous-time feedback protocol alone.« less

  13. Comparison of serum, EDTA plasma and P100 plasma for luminex-based biomarker multiplex assays in patients with chronic obstructive pulmonary disease in the SPIROMICS study.

    PubMed

    O'Neal, Wanda K; Anderson, Wayne; Basta, Patricia V; Carretta, Elizabeth E; Doerschuk, Claire M; Barr, R Graham; Bleecker, Eugene R; Christenson, Stephanie A; Curtis, Jeffrey L; Han, Meilan K; Hansel, Nadia N; Kanner, Richard E; Kleerup, Eric C; Martinez, Fernando J; Miller, Bruce E; Peters, Stephen P; Rennard, Stephen I; Scholand, Mary Beth; Tal-Singer, Ruth; Woodruff, Prescott G; Couper, David J; Davis, Sonia M

    2014-01-08

    As a part of the longitudinal Chronic Obstructive Pulmonary Disease (COPD) study, Subpopulations and Intermediate Outcome Measures in COPD study (SPIROMICS), blood samples are being collected from 3200 subjects with the goal of identifying blood biomarkers for sub-phenotyping patients and predicting disease progression. To determine the most reliable sample type for measuring specific blood analytes in the cohort, a pilot study was performed from a subset of 24 subjects comparing serum, Ethylenediaminetetraacetic acid (EDTA) plasma, and EDTA plasma with proteinase inhibitors (P100). 105 analytes, chosen for potential relevance to COPD, arranged in 12 multiplex and one simplex platform (Myriad-RBM) were evaluated in duplicate from the three sample types from 24 subjects. The reliability coefficient and the coefficient of variation (CV) were calculated. The performance of each analyte and mean analyte levels were evaluated across sample types. 20% of analytes were not consistently detectable in any sample type. Higher reliability and/or smaller CV were determined for 12 analytes in EDTA plasma compared to serum, and for 11 analytes in serum compared to EDTA plasma. While reliability measures were similar for EDTA plasma and P100 plasma for a majority of analytes, CV was modestly increased in P100 plasma for eight analytes. Each analyte within a multiplex produced independent measurement characteristics, complicating selection of sample type for individual multiplexes. There were notable detectability and measurability differences between serum and plasma. Multiplexing may not be ideal if large reliability differences exist across analytes measured within the multiplex, especially if values differ based on sample type. For some analytes, the large CV should be considered during experimental design, and the use of duplicate and/or triplicate samples may be necessary. These results should prove useful for studies evaluating selection of samples for evaluation of potential blood biomarkers.

  14. Comparison of serum, EDTA plasma and P100 plasma for luminex-based biomarker multiplex assays in patients with chronic obstructive pulmonary disease in the SPIROMICS study

    PubMed Central

    2014-01-01

    Background As a part of the longitudinal Chronic Obstructive Pulmonary Disease (COPD) study, Subpopulations and Intermediate Outcome Measures in COPD study (SPIROMICS), blood samples are being collected from 3200 subjects with the goal of identifying blood biomarkers for sub-phenotyping patients and predicting disease progression. To determine the most reliable sample type for measuring specific blood analytes in the cohort, a pilot study was performed from a subset of 24 subjects comparing serum, Ethylenediaminetetraacetic acid (EDTA) plasma, and EDTA plasma with proteinase inhibitors (P100™). Methods 105 analytes, chosen for potential relevance to COPD, arranged in 12 multiplex and one simplex platform (Myriad-RBM) were evaluated in duplicate from the three sample types from 24 subjects. The reliability coefficient and the coefficient of variation (CV) were calculated. The performance of each analyte and mean analyte levels were evaluated across sample types. Results 20% of analytes were not consistently detectable in any sample type. Higher reliability and/or smaller CV were determined for 12 analytes in EDTA plasma compared to serum, and for 11 analytes in serum compared to EDTA plasma. While reliability measures were similar for EDTA plasma and P100 plasma for a majority of analytes, CV was modestly increased in P100 plasma for eight analytes. Each analyte within a multiplex produced independent measurement characteristics, complicating selection of sample type for individual multiplexes. Conclusions There were notable detectability and measurability differences between serum and plasma. Multiplexing may not be ideal if large reliability differences exist across analytes measured within the multiplex, especially if values differ based on sample type. For some analytes, the large CV should be considered during experimental design, and the use of duplicate and/or triplicate samples may be necessary. These results should prove useful for studies evaluating selection of samples for evaluation of potential blood biomarkers. PMID:24397870

  15. Entanglement distillation protocols and number theory

    NASA Astrophysics Data System (ADS)

    Bombin, H.; Martin-Delgado, M. A.

    2005-09-01

    We show that the analysis of entanglement distillation protocols for qudits of arbitrary dimension D benefits from applying basic concepts from number theory, since the set ZDn associated with Bell diagonal states is a module rather than a vector space. We find that a partition of ZDn into divisor classes characterizes the invariant properties of mixed Bell diagonal states under local permutations. We construct a very general class of recursion protocols by means of unitary operations implementing these local permutations. We study these distillation protocols depending on whether we use twirling operations in the intermediate steps or not, and we study them both analytically and numerically with Monte Carlo methods. In the absence of twirling operations, we construct extensions of the quantum privacy algorithms valid for secure communications with qudits of any dimension D . When D is a prime number, we show that distillation protocols are optimal both qualitatively and quantitatively.

  16. RCRA Facility investigation report for Waste Area Grouping 6 at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Volume 5, Technical Memorandums 06-09A, 06-10A, and 06-12A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    This report provides a detailed summary of the activities carried out to sample groundwater at Waste Area Grouping (WAG) 6. The analytical results for samples collected during Phase 1, Activity 2 of the WAG 6 Resource Conservation and Recovery Act Facility Investigation (RFI) are also presented. In addition, analytical results for Phase 1, activity sampling events for which data were not previously reported are included in this TM. A summary of the groundwater sampling activities of WAG 6, to date, are given in the Introduction. The Methodology section describes the sampling procedures and analytical parameters. Six attachments are included. Attachmentsmore » 1 and 2 provide analytical results for selected RFI groundwater samples and ORNL sampling event. Attachment 3 provides a summary of the contaminants detected in each well sampled for all sampling events conducted at WAG 6. Bechtel National Inc. (BNI)/IT Corporation Contract Laboratory (IT) RFI analytical methods and detection limits are given in Attachment 4. Attachment 5 provides the Oak Ridge National Laboratory (ORNL)/Analytical Chemistry Division (ACD) analytical methods and detection limits and Resource Conservation and Recovery Act (RCRA) quarterly compliance monitoring (1988--1989). Attachment 6 provides ORNL/ACD groundwater analytical methods and detection limits (for the 1990 RCRA semi-annual compliance monitoring).« less

  17. Correlation Between Iron and alpha and pi Glutathione-S-Transferase Levels in Humans

    DTIC Science & Technology

    2012-09-01

    assays were performed as described in the Biotrin High Sensitivity Alpha GST EIA kit protocol. First, serum samples were diluted 1:10 with wash solution...immunosorbent assays were performed as described in the Biotrin Pi GST EIA kit protocol. First, plasma samples were diluted 1:5 with sample diluent...immunosorbent assays were performed as described in the AssayMax Human Transferrin ELISA kit protocol. First, serum samples were diluted 1:2000 with MIX

  18. Methods for Monitoring Fish Communities of Buffalo National River and Ozark National Scenic Riverways in the Ozark Plateaus of Arkansas and Missouri: Version 1.0

    USGS Publications Warehouse

    Petersen, James C.; Justus, B.G.; Dodd, H.R.; Bowles, D.E.; Morrison, L.W.; Williams, M.H.; Rowell, G.A.

    2008-01-01

    Buffalo National River located in north-central Arkansas, and Ozark National Scenic Riverways, located in southeastern Missouri, are the two largest units of the National Park Service in the Ozark Plateaus physiographic province. The purpose of this report is to provide a protocol that will be used by the National Park Service to sample fish communities and collect related water-quality, habitat, and stream discharge data of Buffalo National River and Ozark National Scenic Riverways to meet inventory and long-term monitoring objectives. The protocol includes (1) a protocol narrative, (2) several standard operating procedures, and (3) supplemental information helpful for implementation of the protocol. The protocol narrative provides background information about the protocol such as the rationale of why a particular resource or resource issue was selected for monitoring, information concerning the resource or resource issue of interest, a description of how monitoring results will inform management decisions, and a discussion of the linkages between this and other monitoring projects. The standard operating procedures cover preparation, training, reach selection, water-quality sampling, fish community sampling, physical habitat collection, measuring stream discharge, equipment maintenance and storage, data management and analysis, reporting, and protocol revision procedures. Much of the information in the standard operating procedures was gathered from existing protocols of the U.S. Geological Survey National Water Quality Assessment program or other sources. Supplemental information that would be helpful for implementing the protocol is included. This information includes information on fish species known or suspected to occur in the parks, sample sites, sample design, fish species traits, index of biotic integrity metrics, sampling equipment, and field forms.

  19. DIGE Analysis of Human Tissues.

    PubMed

    Gelfi, Cecilia; Capitanio, Daniele

    2018-01-01

    Two-dimensional difference gel electrophoresis (2-D DIGE) is an advanced and elegant gel electrophoretic analytical tool for comparative protein assessment. It is based on two-dimensional gel electrophoresis (2-DE) separation of fluorescently labeled protein extracts. The tagging procedures are designed to not interfere with the chemical properties of proteins with respect to their pI and electrophoretic mobility, once a proper labeling protocol is followed. The two-dye or three-dye systems can be adopted and their choice depends on specific applications. Furthermore, the use of an internal pooled standard makes 2-D DIGE a highly accurate quantitative method enabling multiple protein samples to be separated on the same two-dimensional gel. The image matching and cross-gel statistical analysis generates robust quantitative results making data validation by independent technologies successful.

  20. Tissue Sampling Guides for Porcine Biomedical Models.

    PubMed

    Albl, Barbara; Haesner, Serena; Braun-Reichhart, Christina; Streckel, Elisabeth; Renner, Simone; Seeliger, Frank; Wolf, Eckhard; Wanke, Rüdiger; Blutke, Andreas

    2016-04-01

    This article provides guidelines for organ and tissue sampling adapted to porcine animal models in translational medical research. Detailed protocols for the determination of sampling locations and numbers as well as recommendations on the orientation, size, and trimming direction of samples from ∼50 different porcine organs and tissues are provided in the Supplementary Material. The proposed sampling protocols include the generation of samples suitable for subsequent qualitative and quantitative analyses, including cryohistology, paraffin, and plastic histology; immunohistochemistry;in situhybridization; electron microscopy; and quantitative stereology as well as molecular analyses of DNA, RNA, proteins, metabolites, and electrolytes. With regard to the planned extent of sampling efforts, time, and personnel expenses, and dependent upon the scheduled analyses, different protocols are provided. These protocols are adjusted for (I) routine screenings, as used in general toxicity studies or in analyses of gene expression patterns or histopathological organ alterations, (II) advanced analyses of single organs/tissues, and (III) large-scale sampling procedures to be applied in biobank projects. Providing a robust reference for studies of porcine models, the described protocols will ensure the efficiency of sampling, the systematic recovery of high-quality samples representing the entire organ or tissue as well as the intra-/interstudy comparability and reproducibility of results. © The Author(s) 2016.

Top