Groundwater quality in the Delaware and St. Lawrence River Basins, New York, 2010
Nystrom, Elizabeth A.
2012-01-01
Water quality in both study areas is generally good, but concentrations of some constituents equaled or exceeded current or proposed Federal or New York State drinking-water standards. The standards exceeded are color (one sample in the St. Lawrence study area), pH (three samples in the Delaware study area), sodium (one sample in the St. Lawrence study area), total dissolved solids (one sample in the St. Lawrence study area), aluminum (one sample in the Delaware study area and one sample in the St. Lawrence study area), iron (seven samples in the St. Lawrence study area), manganese (one sample in the Delaware study area and five samples in the St. Lawrence study area), gross alpha radioactivity (one sample in the St. Lawrence study area), radon-222 (10 samples in the Delaware study area and 14 samples in the St. Lawrence study area), and bacteria (5 samples in the Delaware study area and 10 samples in the St. Lawrence study area). E. coli bacteria were detected in samples from two wells in the St. Lawrence study area. Concentrations of chloride, fluoride, sulfate, nitrate, nitrite, antimony, arsenic, barium, beryllium, cadmium, chromium, copper, lead, mercury, selenium, silver, thallium, zinc, and uranium did not exceed existing drinking-water standards in any of the samples collected.
[A comparison of convenience sampling and purposive sampling].
Suen, Lee-Jen Wu; Huang, Hui-Man; Lee, Hao-Hsien
2014-06-01
Convenience sampling and purposive sampling are two different sampling methods. This article first explains sampling terms such as target population, accessible population, simple random sampling, intended sample, actual sample, and statistical power analysis. These terms are then used to explain the difference between "convenience sampling" and purposive sampling." Convenience sampling is a non-probabilistic sampling technique applicable to qualitative or quantitative studies, although it is most frequently used in quantitative studies. In convenience samples, subjects more readily accessible to the researcher are more likely to be included. Thus, in quantitative studies, opportunity to participate is not equal for all qualified individuals in the target population and study results are not necessarily generalizable to this population. As in all quantitative studies, increasing the sample size increases the statistical power of the convenience sample. In contrast, purposive sampling is typically used in qualitative studies. Researchers who use this technique carefully select subjects based on study purpose with the expectation that each participant will provide unique and rich information of value to the study. As a result, members of the accessible population are not interchangeable and sample size is determined by data saturation not by statistical power analysis.
Self-sampling is appropriate for detection of Staphylococcus aureus: a validation study
2012-01-01
Background Studies frequently use nasal swabs to determine Staphylococcus aureus carriage. Self-sampling would be extremely useful in an outhospital research situation, but has not been studied in a healthy population. We studied the similarity of self-samples and investigator-samples in nares and pharynxes of healthy study subjects (hospital staff) in the Netherlands. Methods One hundred and five nursing personnel members were sampled 4 times in random order after viewing an instruction paper: 1) nasal self-sample, 2) pharyngeal self-sample, 3) nasal investigator-sample, and 4) pharyngeal investigator-sample. Results For nasal samples, agreement is 93% with a kappa coefficient of 0.85 (95% CI 0.74-0.96), indicating excellent agreement, for pharyngeal samples agreement is 83% and the kappa coefficient is 0.60 (95% CI 0.43-0.76), indicating good agreement. In both sampling sites self-samples even detected more S. aureus than investigator-samples. Conclusions This means that self-samples are appropriate for detection of Staphylococcus aureus and methicillin-resistant Staphylococcus aureus. PMID:23137281
Paudyal, Priyamvada; Llewellyn, Carrie; Lau, Jason; Mahmud, Mohammad; Smith, Helen
2015-01-01
Background Routine screening is key to sexually transmitted infection (STI) prevention and control. Previous studies suggest that clinic-based screening programmes capture only a small proportion of people with STIs. Self-sampling using non- or minimally invasive techniques may be beneficial for those reluctant to actively engage with conventional sampling methods. We systematically reviewed studies of patients’ experiences of obtaining self-samples to diagnose curable STIs. Methods We conducted an electronic search of MEDLINE, EMBASE, CINAHL, PsychINFO, BNI, and Cochrane Database of Systematic Reviews to identify relevant articles published in English between January 1980 and March 2014. Studies were included if participants self-sampled for the diagnosis of a curable STI and had specifically sought participants’ opinions of their experience, acceptability, preferences, or willingness to self-sample. Results The initial search yielded 558 references. Of these, 45 studies met the inclusion criteria. Thirty-six studies assessed patients’ acceptability and experiences of self-sampling. Pooled results from these studies shows that self-sampling is a highly acceptable method with 85% of patients reporting the method to be well received and acceptable. Twenty-eight studies reported on ease of self-sampling; the majority of patients (88%) in these studies found self-sampling an “easy” procedure. Self-sampling was favoured compared to clinician sampling, and home sampling was preferred to clinic-based sampling. Females and older participants were more accepting of self-sampling. Only a small minority of participants (13%) reported pain during self-sampling. Participants were willing to undergo self-sampling and recommend others. Privacy and safety were the most common concerns. Conclusion Self-sampling for diagnostic testing is well accepted with the majority having a positive experience and willingness to use again. Standardization of self-sampling procedures and rigorous validation of outcome measurement will lead to better comparability across studies. Future studies need to conduct rigorous economic evaluations of self-sampling to inform policy development for the management of STI. PMID:25909508
Sample size in studies on diagnostic accuracy in ophthalmology: a literature survey.
Bochmann, Frank; Johnson, Zoe; Azuara-Blanco, Augusto
2007-07-01
To assess the sample sizes used in studies on diagnostic accuracy in ophthalmology. Design and sources: A survey literature published in 2005. The frequency of reporting calculations of sample sizes and the samples' sizes were extracted from the published literature. A manual search of five leading clinical journals in ophthalmology with the highest impact (Investigative Ophthalmology and Visual Science, Ophthalmology, Archives of Ophthalmology, American Journal of Ophthalmology and British Journal of Ophthalmology) was conducted by two independent investigators. A total of 1698 articles were identified, of which 40 studies were on diagnostic accuracy. One study reported that sample size was calculated before initiating the study. Another study reported consideration of sample size without calculation. The mean (SD) sample size of all diagnostic studies was 172.6 (218.9). The median prevalence of the target condition was 50.5%. Only a few studies consider sample size in their methods. Inadequate sample sizes in diagnostic accuracy studies may result in misleading estimates of test accuracy. An improvement over the current standards on the design and reporting of diagnostic studies is warranted.
Q-Sample Construction: A Critical Step for a Q-Methodological Study.
Paige, Jane B; Morin, Karen H
2016-01-01
Q-sample construction is a critical step in Q-methodological studies. Prior to conducting Q-studies, researchers start with a population of opinion statements (concourse) on a particular topic of interest from which a sample is drawn. These sampled statements are known as the Q-sample. Although literature exists on methodological processes to conduct Q-methodological studies, limited guidance exists on the practical steps to reduce the population of statements to a Q-sample. A case exemplar illustrates the steps to construct a Q-sample in preparation for a study that explored perspectives nurse educators and nursing students hold about simulation design. Experts in simulation and Q-methodology evaluated the Q-sample for readability, clarity, and for representativeness of opinions contained within the concourse. The Q-sample was piloted and feedback resulted in statement refinement. Researchers especially those undertaking Q-method studies for the first time may benefit from the practical considerations to construct a Q-sample offered in this article. © The Author(s) 2014.
Sampling pig farms at the abattoir in a cross-sectional study - Evaluation of a sampling method.
Birkegård, Anna Camilla; Halasa, Tariq; Toft, Nils
2017-09-15
A cross-sectional study design is relatively inexpensive, fast and easy to conduct when compared to other study designs. Careful planning is essential to obtaining a representative sample of the population, and the recommended approach is to use simple random sampling from an exhaustive list of units in the target population. This approach is rarely feasible in practice, and other sampling procedures must often be adopted. For example, when slaughter pigs are the target population, sampling the pigs on the slaughter line may be an alternative to on-site sampling at a list of farms. However, it is difficult to sample a large number of farms from an exact predefined list, due to the logistics and workflow of an abattoir. Therefore, it is necessary to have a systematic sampling procedure and to evaluate the obtained sample with respect to the study objective. We propose a method for 1) planning, 2) conducting, and 3) evaluating the representativeness and reproducibility of a cross-sectional study when simple random sampling is not possible. We used an example of a cross-sectional study with the aim of quantifying the association of antimicrobial resistance and antimicrobial consumption in Danish slaughter pigs. It was not possible to visit farms within the designated timeframe. Therefore, it was decided to use convenience sampling at the abattoir. Our approach was carried out in three steps: 1) planning: using data from meat inspection to plan at which abattoirs and how many farms to sample; 2) conducting: sampling was carried out at five abattoirs; 3) evaluation: representativeness was evaluated by comparing sampled and non-sampled farms, and the reproducibility of the study was assessed through simulated sampling based on meat inspection data from the period where the actual data collection was carried out. In the cross-sectional study samples were taken from 681 Danish pig farms, during five weeks from February to March 2015. The evaluation showed that the sampling procedure was reproducible with results comparable to the collected sample. However, the sampling procedure favoured sampling of large farms. Furthermore, both under-sampled and over-sampled areas were found using scan statistics. In conclusion, sampling conducted at abattoirs can provide a spatially representative sample. Hence it is a possible cost-effective alternative to simple random sampling. However, it is important to assess the properties of the resulting sample so that any potential selection bias can be addressed when reporting the findings. Copyright © 2017 Elsevier B.V. All rights reserved.
Sampling studies to estimate the HIV prevalence rate in female commercial sex workers.
Pascom, Ana Roberta Pati; Szwarcwald, Célia Landmann; Barbosa Júnior, Aristides
2010-01-01
We investigated sampling methods being used to estimate the HIV prevalence rate among female commercial sex workers. The studies were classified according to the adequacy or not of the sample size to estimate HIV prevalence rate and according to the sampling method (probabilistic or convenience). We identified 75 studies that estimated the HIV prevalence rate among female sex workers. Most of the studies employed convenience samples. The sample size was not adequate to estimate HIV prevalence rate in 35 studies. The use of convenience sample limits statistical inference for the whole group. It was observed that there was an increase in the number of published studies since 2005, as well as in the number of studies that used probabilistic samples. This represents a large advance in the monitoring of risk behavior practices and HIV prevalence rate in this group.
Evaluating noninvasive genetic sampling techniques to estimate large carnivore abundance.
Mumma, Matthew A; Zieminski, Chris; Fuller, Todd K; Mahoney, Shane P; Waits, Lisette P
2015-09-01
Monitoring large carnivores is difficult because of intrinsically low densities and can be dangerous if physical capture is required. Noninvasive genetic sampling (NGS) is a safe and cost-effective alternative to physical capture. We evaluated the utility of two NGS methods (scat detection dogs and hair sampling) to obtain genetic samples for abundance estimation of coyotes, black bears and Canada lynx in three areas of Newfoundland, Canada. We calculated abundance estimates using program capwire, compared sampling costs, and the cost/sample for each method relative to species and study site, and performed simulations to determine the sampling intensity necessary to achieve abundance estimates with coefficients of variation (CV) of <10%. Scat sampling was effective for both coyotes and bears and hair snags effectively sampled bears in two of three study sites. Rub pads were ineffective in sampling coyotes and lynx. The precision of abundance estimates was dependent upon the number of captures/individual. Our simulations suggested that ~3.4 captures/individual will result in a < 10% CV for abundance estimates when populations are small (23-39), but fewer captures/individual may be sufficient for larger populations. We found scat sampling was more cost-effective for sampling multiple species, but suggest that hair sampling may be less expensive at study sites with limited road access for bears. Given the dependence of sampling scheme on species and study site, the optimal sampling scheme is likely to be study-specific warranting pilot studies in most circumstances. © 2015 John Wiley & Sons Ltd.
Sample Size in Qualitative Interview Studies: Guided by Information Power.
Malterud, Kirsti; Siersma, Volkert Dirk; Guassora, Ann Dorrit
2015-11-27
Sample sizes must be ascertained in qualitative studies like in quantitative studies but not by the same means. The prevailing concept for sample size in qualitative studies is "saturation." Saturation is closely tied to a specific methodology, and the term is inconsistently applied. We propose the concept "information power" to guide adequate sample size for qualitative studies. Information power indicates that the more information the sample holds, relevant for the actual study, the lower amount of participants is needed. We suggest that the size of a sample with sufficient information power depends on (a) the aim of the study, (b) sample specificity, (c) use of established theory, (d) quality of dialogue, and (e) analysis strategy. We present a model where these elements of information and their relevant dimensions are related to information power. Application of this model in the planning and during data collection of a qualitative study is discussed. © The Author(s) 2015.
Evaluating mixed samples as a source of error in non-invasive genetic studies using microsatellites
Roon, David A.; Thomas, M.E.; Kendall, K.C.; Waits, L.P.
2005-01-01
The use of noninvasive genetic sampling (NGS) for surveying wild populations is increasing rapidly. Currently, only a limited number of studies have evaluated potential biases associated with NGS. This paper evaluates the potential errors associated with analysing mixed samples drawn from multiple animals. Most NGS studies assume that mixed samples will be identified and removed during the genotyping process. We evaluated this assumption by creating 128 mixed samples of extracted DNA from brown bear (Ursus arctos) hair samples. These mixed samples were genotyped and screened for errors at six microsatellite loci according to protocols consistent with those used in other NGS studies. Five mixed samples produced acceptable genotypes after the first screening. However, all mixed samples produced multiple alleles at one or more loci, amplified as only one of the source samples, or yielded inconsistent electropherograms by the final stage of the error-checking process. These processes could potentially reduce the number of individuals observed in NGS studies, but errors should be conservative within demographic estimates. Researchers should be aware of the potential for mixed samples and carefully design gel analysis criteria and error checking protocols to detect mixed samples.
Methodology Series Module 5: Sampling Strategies.
Setia, Maninder Singh
2016-01-01
Once the research question and the research design have been finalised, it is important to select the appropriate sample for the study. The method by which the researcher selects the sample is the ' Sampling Method'. There are essentially two types of sampling methods: 1) probability sampling - based on chance events (such as random numbers, flipping a coin etc.); and 2) non-probability sampling - based on researcher's choice, population that accessible & available. Some of the non-probability sampling methods are: purposive sampling, convenience sampling, or quota sampling. Random sampling method (such as simple random sample or stratified random sample) is a form of probability sampling. It is important to understand the different sampling methods used in clinical studies and mention this method clearly in the manuscript. The researcher should not misrepresent the sampling method in the manuscript (such as using the term ' random sample' when the researcher has used convenience sample). The sampling method will depend on the research question. For instance, the researcher may want to understand an issue in greater detail for one particular population rather than worry about the ' generalizability' of these results. In such a scenario, the researcher may want to use ' purposive sampling' for the study.
Morrison, Christopher; Lee, Juliet P.; Gruenewald, Paul J.; Marzell, Miesha
2015-01-01
Location-based sampling is a method to obtain samples of people within ecological contexts relevant to specific public health outcomes. Random selection increases generalizability, however in some circumstances (such as surveying bar patrons) recruitment conditions increase risks of sample bias. We attempted to recruit representative samples of bars and patrons in six California cities, but low response rates precluded meaningful analysis. A systematic review of 24 similar studies revealed that none addressed the key shortcomings of our study. We recommend steps to improve studies that use location-based sampling: (i) purposively sample places of interest, (ii) utilize recruitment strategies appropriate to the environment, and (iii) provide full information on response rates at all levels of sampling. PMID:26574657
Methodology Series Module 5: Sampling Strategies
Setia, Maninder Singh
2016-01-01
Once the research question and the research design have been finalised, it is important to select the appropriate sample for the study. The method by which the researcher selects the sample is the ‘ Sampling Method’. There are essentially two types of sampling methods: 1) probability sampling – based on chance events (such as random numbers, flipping a coin etc.); and 2) non-probability sampling – based on researcher's choice, population that accessible & available. Some of the non-probability sampling methods are: purposive sampling, convenience sampling, or quota sampling. Random sampling method (such as simple random sample or stratified random sample) is a form of probability sampling. It is important to understand the different sampling methods used in clinical studies and mention this method clearly in the manuscript. The researcher should not misrepresent the sampling method in the manuscript (such as using the term ‘ random sample’ when the researcher has used convenience sample). The sampling method will depend on the research question. For instance, the researcher may want to understand an issue in greater detail for one particular population rather than worry about the ‘ generalizability’ of these results. In such a scenario, the researcher may want to use ‘ purposive sampling’ for the study. PMID:27688438
Sampling in Developmental Science: Situations, Shortcomings, Solutions, and Standards.
Bornstein, Marc H; Jager, Justin; Putnick, Diane L
2013-12-01
Sampling is a key feature of every study in developmental science. Although sampling has far-reaching implications, too little attention is paid to sampling. Here, we describe, discuss, and evaluate four prominent sampling strategies in developmental science: population-based probability sampling, convenience sampling, quota sampling, and homogeneous sampling. We then judge these sampling strategies by five criteria: whether they yield representative and generalizable estimates of a study's target population, whether they yield representative and generalizable estimates of subsamples within a study's target population, the recruitment efforts and costs they entail, whether they yield sufficient power to detect subsample differences, and whether they introduce "noise" related to variation in subsamples and whether that "noise" can be accounted for statistically. We use sample composition of gender, ethnicity, and socioeconomic status to illustrate and assess the four sampling strategies. Finally, we tally the use of the four sampling strategies in five prominent developmental science journals and make recommendations about best practices for sample selection and reporting.
Hill, Virginia; Cairns, Thomas; Schaffer, Michael
2008-03-21
Hair samples were contaminated by rubbing with cocaine (COC) followed by sweat application, multiple shampoo treatments and storage. The samples were then washed with isopropanol for 15min, followed by sequential aqueous washes totaling 3.5h. The amount of drug in the last wash was used to calculate a wash criterion to determine whether samples were positive due to use or contamination. Analyses of cocaine and metabolites were done by LC/MS/MS. These procedures were applied to samples produced by a U.S. government-sponsored cooperative study, in which this laboratory participated, and to samples in a parallel in-house study. All contaminated samples in both studies were correctly identified as contaminated by cutoff, benzoylecgonine (BE) presence, BE ratio, and/or the wash criterion. A method for determining hair porosity was applied to samples in both studies, and porosity characteristics of hair are discussed as they relate to experimental and real-world contamination of hair, preparation of proficiency survey samples, and analysis of unknown hair samples.
K, Punith; K, Lalitha; G, Suman; BS, Pradeep; Kumar K, Jayanth
2008-01-01
Research Question: Is LQAS technique better than cluster sampling technique in terms of resources to evaluate the immunization coverage in an urban area? Objective: To assess and compare the lot quality assurance sampling against cluster sampling in the evaluation of primary immunization coverage. Study Design: Population-based cross-sectional study. Study Setting: Areas under Mathikere Urban Health Center. Study Subjects: Children aged 12 months to 23 months. Sample Size: 220 in cluster sampling, 76 in lot quality assurance sampling. Statistical Analysis: Percentages and Proportions, Chi square Test. Results: (1) Using cluster sampling, the percentage of completely immunized, partially immunized and unimmunized children were 84.09%, 14.09% and 1.82%, respectively. With lot quality assurance sampling, it was 92.11%, 6.58% and 1.31%, respectively. (2) Immunization coverage levels as evaluated by cluster sampling technique were not statistically different from the coverage value as obtained by lot quality assurance sampling techniques. Considering the time and resources required, it was found that lot quality assurance sampling is a better technique in evaluating the primary immunization coverage in urban area. PMID:19876474
The generalization ability of SVM classification based on Markov sampling.
Xu, Jie; Tang, Yuan Yan; Zou, Bin; Xu, Zongben; Li, Luoqing; Lu, Yang; Zhang, Baochang
2015-06-01
The previously known works studying the generalization ability of support vector machine classification (SVMC) algorithm are usually based on the assumption of independent and identically distributed samples. In this paper, we go far beyond this classical framework by studying the generalization ability of SVMC based on uniformly ergodic Markov chain (u.e.M.c.) samples. We analyze the excess misclassification error of SVMC based on u.e.M.c. samples, and obtain the optimal learning rate of SVMC for u.e.M.c. We also introduce a new Markov sampling algorithm for SVMC to generate u.e.M.c. samples from given dataset, and present the numerical studies on the learning performance of SVMC based on Markov sampling for benchmark datasets. The numerical studies show that the SVMC based on Markov sampling not only has better generalization ability as the number of training samples are bigger, but also the classifiers based on Markov sampling are sparsity when the size of dataset is bigger with regard to the input dimension.
Yeheyis, Likawent; Kijora, Claudia; Wink, Michael; Peters, Kurt J
2011-01-01
The effect of a traditional Ethiopian lupin processing method on the chemical composition of lupin seed samples was studied. Two sampling districts, namely Mecha and Sekela, representing the mid- and high-altitude areas of north-western Ethiopia, respectively, were randomly selected. Different types of traditionally processed and marketed lupin seed samples (raw, roasted, and finished) were collected in six replications from each district. Raw samples are unprocessed, and roasted samples are roasted using firewood. Finished samples are those ready for human consumption as snack. Thousand seed weight for raw and roasted samples within a study district was similar (P > 0.05), but it was lower (P < 0.01) for finished samples compared to raw and roasted samples. The crude fibre content of finished lupin seed sample from Mecha was lower (P < 0.01) than that of raw and roasted samples. However, the different lupin samples from Sekela had similar crude fibre content (P > 0.05). The crude protein and crude fat contents of finished samples within a study district were higher (P < 0.01) than those of raw and roasted samples, respectively. Roasting had no effect on the crude protein content of lupin seed samples. The crude ash content of raw and roasted lupin samples within a study district was higher (P < 0.01) than that of finished lupin samples of the respective study districts. The content of quinolizidine alkaloids of finished lupin samples was lower than that of raw and roasted samples. There was also an interaction effect between location and lupin sample type. The traditional processing method of lupin seeds in Ethiopia has a positive contribution improving the crude protein and crude fat content, and lowering the alkaloid content of the finished product. The study showed the possibility of adopting the traditional processing method to process bitter white lupin for the use as protein supplement in livestock feed in Ethiopia, but further work has to be done on the processing method and animal evaluation.
Preserving, Enhancing, and Continuing the Scientific Legacy of the Apollo Sample Suite
NASA Astrophysics Data System (ADS)
Zeigler, R. A.; Evans, C. A.; Lehnert, K.; Cai, Y.; Todd, N. S.
2016-12-01
From 1969 to 1972, Apollo astronauts collected 382 kg of rocks, soils, and core samples from six geologically diverse locations on the Moon. In the nearly 50 years since the samples were collected, over 3000 different studies have been conducted using the nearly 2200 different Apollo samples. Despite the maturity of the sample collection, many new studies of lunar samples are undertaken each year, with an average of >55 requests and >600 distinct subsamples allocated annually over the past five years. The Apollo samples are a finite resource, however. Although new studies are encouraged, it is important that new studies do not duplicate previous studies, and where possible, leverage previous results to inform and enhance the current studies. This helps to preserve the samples and scientific funding, both of which are precious resources. We have initiated several new efforts to rescue some of the early analyses from these samples, including unpublished analytical data. We are actively scanning NASA documentation in paper form that is related to the Apollo missions and sample processing, and we are collaborating with IEDA to establish a geochemical data base called MoonDB. To populate this database, we are actively working with about a dozen prominent lunar PIs to organize and transcribe years of both published and unpublished data, making it available to all researchers. This effort will also take advantage of new online analytical tools like PetDB. There have already been tangible results from the MoonDB data rescue effort. A pilot project involving the rescue of geochemical data of John Delano on Apollo pyroclastic glasses has already been referenced in multiple Apollo sample requests, and in fact, the compiled data was used as part of one of the new studies. Similarly, scanned sample handling reports have been utilized to find previously analyzed samples that were appropriate to fulfill new sample requests. We have also begun to image the Apollo samples using (1) micro-CT scanning to document the interior structure of samples, and (2) comprehensive high resolution photography of samples, enabling high resolution 3D reconstructions of the samples. Both efforts will provide comprehensive access to these samples and allow for more targeted requests, and thus better curation of the samples for decades to come.
Preserving, Enhancing, and Continuing the Scientific Legacy of the Apollo Sample Suite
NASA Technical Reports Server (NTRS)
Zeigler, Ryan; Evans, Cindy; Cai, Yue; Lehnert, Kerstin; Todd, Nancy; Blumenfeld, Erika
2016-01-01
From 1969 to 1972, Apollo astronauts collected 382 kg of rocks, soils, and core samples from six geologically diverse locations on the Moon. In the nearly 50 years since the samples were collected, over 3000 different studies have been conducted using the nearly 2200 different Apollo samples. Despite the maturity of the sample collection, many new studies of lunar samples are undertaken each year, with an average of more than 55 requests and more than 600 distinct subsamples allocated annually over the past five years. The Apollo samples are a finite resource, however. Although new studies are encouraged, it is important that new studies do not duplicate previous studies, and where possible, leverage previous results to inform and enhance the current studies. This helps to preserve the samples and scientific funding, both of which are precious resources. We have initiated several new efforts to rescue some of the early analyses from these samples, including unpublished analytical data. We are actively scanning NASA documentation in paper form that is related to the Apollo missions and sample processing, and we are collaborating with IEDA to establish a geochemical data base called MoonDB. To populate this database, we are actively working with about a dozen prominent lunar PIs to organize and transcribe years of both published and unpublished data, making it available to all researchers. This effort will also take advantage of new online analytical tools like PetDB. There have already been tangible results from the MoonDB data rescue effort. A pilot project involving the rescue of geochemical data of John Delano on Apollo pyroclastic glasses has already been referenced in multiple Apollo sample requests, and in fact, the compiled data was used as part of one of the new studies. Similarly, scanned sample handling reports have been utilized to find previously analyzed samples that were appropriate to fulfill new sample requests. We have also begun to image the Apollo samples using (1) micro-CT scanning to document the interior structure of samples, and (2) comprehensive high resolution photography of samples, enabling high resolution 3D reconstructions of the samples. Both efforts will provide comprehensive access to these samples and allow for more targeted requests, and thus better curation of the samples for decades to come.
King, Harley D.; Chaffee, Maurice A.
2000-01-01
INTRODUCTION In 1996-1998 the U.S. Geological Survey (USGS) conducted a geochemical study of the Bureau of Land Management's (BLM) 5.5 million-acre Northern and Eastern Colorado Desert Resource Area (usually referred to as the NECD in this report), Imperial, Riverside, and San Bernardino Counties, southeastern California (figure 1). This study was done in support of the BLM's Coordinated Management Plan for the area. This report presents analytical data from this study. To provide comprehensive coverage of the NECD, we compiled and examined all available geochemical data, in digital form, from previous studies in the area, and made sample-site plots to aid in determining where sample-site coverage and analyses were sufficient, which samples should be re-analyzed, and where additional sampling was needed. Previous investigations conducted in parts of the current study area included the National Uranium Resource Evaluation (NURE) program studies of the Needles and Salton Sea 1? x 2? quadrangles; USGS studies of 12 BLM Wilderness Study Areas (WSAs) (Big Maria Mountains, Chemehuevi Mountains, Chuckwalla Mountains, Coxcomb Mountains, Mecca Hills, Orocopia Mountains, Palen-McCoy, Picacho Peak, Riverside Mountains, Sheephole Valley (also known as Sheep Hole/Cadiz), Turtle Mountains, and Whipple Mountains); and USGS studies in the Needles and El Centro 1? x 2? quadrangles done during the early 1990s as part of a project to identify the regional geochemistry of southern California. Areas where we did new sampling of rocks and stream sediments are mainly in the Chocolate Mountain Aerial Gunnery Range and in Joshua Tree National Park, which extends into the west-central part of the NECD, as shown in figure 1 and figure 2. This report contains analytical data for 132 rock samples and 1,245 stream-sediment samples collected by the USGS, and 362 stream-sediment samples and 189 soil samples collected during the NURE program. All samples are from the Northern and Eastern Colorado Desert BLM Resource Area and vicinity. Included in the 1,245 stream-sediment samples collected by the USGS are 284 samples collected as part of the current study, 817 samples collected as part of investigations of the12 BLM WSAs and re-analyzed for the present study, 45 samples from the Needles 1? X 2? quadrangle, and 99 samples from the El Centro 1? X 2? quadrangle. The NURE stream-sediment and soil samples were re-analyzed as part of the USGS study in the Needles quadrangle. Analytical data for samples from the Chocolate Mountain Aerial Gunnery Range, which is located within the area of the NECD, were previously reported (King and Chaffee, 1999a). For completeness, these results are also included in this report. Analytical data for samples from the area of Joshua Tree National Park that is within the NECD have also been reported (King and Chaffee, 1999b). These results are not included in this report. The analytical data presented here can be used for baseline geochemical, mineral resource, and environmental geochemical studies.
Capturing heterogeneity: The role of a study area's extent for estimating mean throughfall
NASA Astrophysics Data System (ADS)
Zimmermann, Alexander; Voss, Sebastian; Metzger, Johanna Clara; Hildebrandt, Anke; Zimmermann, Beate
2016-11-01
The selection of an appropriate spatial extent of a sampling plot is one among several important decisions involved in planning a throughfall sampling scheme. In fact, the choice of the extent may determine whether or not a study can adequately characterize the hydrological fluxes of the studied ecosystem. Previous attempts to optimize throughfall sampling schemes focused on the selection of an appropriate sample size, support, and sampling design, while comparatively little attention has been given to the role of the extent. In this contribution, we investigated the influence of the extent on the representativeness of mean throughfall estimates for three forest ecosystems of varying stand structure. Our study is based on virtual sampling of simulated throughfall fields. We derived these fields from throughfall data sampled in a simply structured forest (young tropical forest) and two heterogeneous forests (old tropical forest, unmanaged mixed European beech forest). We then sampled the simulated throughfall fields with three common extents and various sample sizes for a range of events and for accumulated data. Our findings suggest that the size of the study area should be carefully adapted to the complexity of the system under study and to the required temporal resolution of the throughfall data (i.e. event-based versus accumulated). Generally, event-based sampling in complex structured forests (conditions that favor comparatively long autocorrelations in throughfall) requires the largest extents. For event-based sampling, the choice of an appropriate extent can be as important as using an adequate sample size.
Ambient air metallic pollutant study at HAF areas during 2013-2014
NASA Astrophysics Data System (ADS)
Fang, Guor-Cheng; Kuo, Yu-Chen; Zhuang, Yuan-Jie
2015-05-01
This study characterized diurnal variations of the total suspended particulate (TSP) concentrations, dry deposition flux and dry deposition velocity of metallic elements at Taichung Harbor (Harbor), Gong Ming Junior High School (Airport) and Sha lu Farmland (Farmland) sampling sites in central Taiwan between August, 2013 and July, 2014 in this study. The result indicated that: 1) the ambient air particulate concentrations, dry depositions were displayed as Harbor > Farmland > Airport during the day time sampling period. However, dry deposition velocities were shown as Airport > Harbor > Farmland for this study. 2) The ambient air particulate concentrations, dry depositions were displayed as Airport > Harbor > Farmland during the night time sampling period. However, dry deposition velocities were shown as Farmland > Harbor > Airport for this study. 3) The metallic element Zn has the average highest concentrations at Airport, Harbor and Farmland among all the metallic elements during the day time sampling period in this study. 4) There were significant differences for the metallic elements (Cr, Cu, Zn and Pb) in dry depositions at these three characteristic sampling sites (HAF) for the night time sampling period. The only exception is metallic element Cd. It displayed that there were no significant differences for the metallic element Cd at the Airport and Farmland sampling sites during the night time sampling period. 5) The average highest values for the metallic element Cu in TSP among the three characteristic sampling sites occurred during the fall and winter seasons for this study. As for the dry depositions, the average highest values in dry deposition among the three characteristic sampling sites occurred during the spring and summer seasons for this study. 6) The average highest values for the metallic element Cd in TSP among the three characteristic sampling sites occurred during the spring and summer seasons for this study. As for the dry depositions, the average highest values in dry deposition among the three characteristic sampling sites occurred during fall and winter for this study.
Is it really theoretical? A review of sampling in grounded theory studies in nursing journals.
McCrae, Niall; Purssell, Edward
2016-10-01
Grounded theory is a distinct method of qualitative research, where core features are theoretical sampling and constant comparative analysis. However, inconsistent application of these activities has been observed in published studies. This review assessed the use of theoretical sampling in grounded theory studies in nursing journals. An adapted systematic review was conducted. Three leading nursing journals (2010-2014) were searched for studies stating grounded theory as the method. Sampling was assessed using a concise rating tool. A high proportion (86%) of the 134 articles described an iterative process of data collection and analysis. However, half of the studies did not demonstrate theoretical sampling, with many studies declaring or indicating a purposive sampling approach throughout. Specific reporting guidelines for grounded theory studies should be developed to ensure that study reports describe an iterative process of fieldwork and theoretical development. © 2016 John Wiley & Sons Ltd.
42 CFR 402.109 - Statistical sampling.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 2 2011-10-01 2011-10-01 false Statistical sampling. 402.109 Section 402.109... Statistical sampling. (a) Purpose. CMS or OIG may introduce the results of a statistical sampling study to... or caused to be presented. (b) Prima facie evidence. The results of the statistical sampling study...
42 CFR 402.109 - Statistical sampling.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Statistical sampling. 402.109 Section 402.109... Statistical sampling. (a) Purpose. CMS or OIG may introduce the results of a statistical sampling study to... or caused to be presented. (b) Prima facie evidence. The results of the statistical sampling study...
Brodaty, Henry; Mothakunnel, Annu; de Vel-Palumbo, Melissa; Ames, David; Ellis, Kathryn A; Reppermund, Simone; Kochan, Nicole A; Savage, Greg; Trollor, Julian N; Crawford, John; Sachdev, Perminder S
2014-01-01
We examined whether differences in findings of studies examining mild cognitive impairment (MCI) were associated with recruitment methods by comparing sample characteristics in two contemporaneous Australian studies, using population-based and convenience sampling. The Sydney Memory and Aging Study invited participants randomly from the electoral roll in defined geographic areas in Sydney. The Australian Imaging, Biomarkers and Lifestyle Study of Ageing recruited cognitively normal (CN) individuals via media appeals and MCI participants via referrals from clinicians in Melbourne and Perth. Demographic and cognitive variables were harmonized, and similar diagnostic criteria were applied to both samples retrospectively. CN participants recruited via convenience sampling were younger, better educated, more likely to be married and have a family history of dementia, and performed better cognitively than those recruited via population-based sampling. MCI participants recruited via population-based sampling had better memory performance and were less likely to carry the apolipoprotein E ε4 allele than clinically referred participants but did not differ on other demographic variables. A convenience sample of normal controls is likely to be younger and better functioning and that of an MCI group likely to perform worse than a purportedly random sample. Sampling bias should be considered when interpreting findings. Copyright © 2014 Elsevier Inc. All rights reserved.
Urban Land Cover Mapping Accuracy Assessment - A Cost-benefit Analysis Approach
NASA Astrophysics Data System (ADS)
Xiao, T.
2012-12-01
One of the most important components in urban land cover mapping is mapping accuracy assessment. Many statistical models have been developed to help design simple schemes based on both accuracy and confidence levels. It is intuitive that an increased number of samples increases the accuracy as well as the cost of an assessment. Understanding cost and sampling size is crucial in implementing efficient and effective of field data collection. Few studies have included a cost calculation component as part of the assessment. In this study, a cost-benefit sampling analysis model was created by combining sample size design and sampling cost calculation. The sampling cost included transportation cost, field data collection cost, and laboratory data analysis cost. Simple Random Sampling (SRS) and Modified Systematic Sampling (MSS) methods were used to design sample locations and to extract land cover data in ArcGIS. High resolution land cover data layers of Denver, CO and Sacramento, CA, street networks, and parcel GIS data layers were used in this study to test and verify the model. The relationship between the cost and accuracy was used to determine the effectiveness of each sample method. The results of this study can be applied to other environmental studies that require spatial sampling.
Sampling guidelines for oral fluid-based surveys of group-housed animals.
Rotolo, Marisa L; Sun, Yaxuan; Wang, Chong; Giménez-Lirola, Luis; Baum, David H; Gauger, Phillip C; Harmon, Karen M; Hoogland, Marlin; Main, Rodger; Zimmerman, Jeffrey J
2017-09-01
Formulas and software for calculating sample size for surveys based on individual animal samples are readily available. However, sample size formulas are not available for oral fluids and other aggregate samples that are increasingly used in production settings. Therefore, the objective of this study was to develop sampling guidelines for oral fluid-based porcine reproductive and respiratory syndrome virus (PRRSV) surveys in commercial swine farms. Oral fluid samples were collected in 9 weekly samplings from all pens in 3 barns on one production site beginning shortly after placement of weaned pigs. Samples (n=972) were tested by real-time reverse-transcription PCR (RT-rtPCR) and the binary results analyzed using a piecewise exponential survival model for interval-censored, time-to-event data with misclassification. Thereafter, simulation studies were used to study the barn-level probability of PRRSV detection as a function of sample size, sample allocation (simple random sampling vs fixed spatial sampling), assay diagnostic sensitivity and specificity, and pen-level prevalence. These studies provided estimates of the probability of detection by sample size and within-barn prevalence. Detection using fixed spatial sampling was as good as, or better than, simple random sampling. Sampling multiple barns on a site increased the probability of detection with the number of barns sampled. These results are relevant to PRRSV control or elimination projects at the herd, regional, or national levels, but the results are also broadly applicable to contagious pathogens of swine for which oral fluid tests of equivalent performance are available. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Kern, Margaret L.; Hampson, Sarah E.; Goldberg, Lewis R.; Friedman, Howard S.
2013-01-01
The present study used a collaborative framework to integrate two long-term prospective studies: the Terman Life Cycle Study and the Hawaii Personality and Health Longitudinal Study. Using a five-factor personality-trait framework, teacher assessments of child personality were rationally and empirically aligned to establish similar factor structures across samples. Comparable items related to adult self-rated health, education, and alcohol use were harmonized, and data were pooled on harmonized items. A structural model was estimated, allowing paths to differ by sample. Harmonized child personality factors were then used to examine markers of physiological dysfunction in the Hawaii sample and mortality risk in the Terman sample. Harmonized conscientiousness predicted less physiological dysfunction in the Hawaii sample and lower mortality risk in the Terman sample. These results illustrate how collaborative, integrative work with multiple samples offers the exciting possibility that samples from different cohorts and ages can be linked together to directly test lifespan theories of personality and health. PMID:23231689
Prevalence of Mixed-Methods Sampling Designs in Social Science Research
ERIC Educational Resources Information Center
Collins, Kathleen M. T.
2006-01-01
The purpose of this mixed-methods study was to document the prevalence of sampling designs utilised in mixed-methods research and to examine the interpretive consistency between interpretations made in mixed-methods studies and the sampling design used. Classification of studies was based on a two-dimensional mixed-methods sampling model. This…
General statistical considerations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eberhardt, L L; Gilbert, R O
From NAEG plutonium environmental studies program meeting; Las Vegas, Nevada, USA (2 Oct 1973). The high sampling variability encountered in environmental plutonium studies along with high analytical costs makes it very important that efficient soil sampling plans be used. However, efficient sampling depends on explicit and simple statements of the objectives of the study. When there are multiple objectives it may be difficult to devise a wholly suitable sampling scheme. Sampling for long-term changes in plutonium concentration in soils may also be complex and expensive. Further attention to problems associated with compositing samples is recommended, as is the consistent usemore » of random sampling as a basic technique. (auth)« less
Valder, Joshua F.; Delzer, Gregory C.; Price, Curtis V.; Sandstrom, Mark W.
2008-01-01
The National Water-Quality Assessment (NAWQA) Program of the U.S. Geological Survey (USGS) began implementing Source Water-Quality Assessments (SWQAs) in 2002 that focus on characterizing the quality of source water and finished water of aquifers and major rivers used by some of the larger community water systems in the United States. As used for SWQA studies, source water is the raw (ambient) water collected at the supply well prior to water treatment (for ground water) or the raw (ambient) water collected from the river near the intake (for surface water). Finished water is the water that is treated, which typically involves, in part, the addition of chlorine or other disinfection chemicals to remove pathogens, and is ready to be delivered to consumers. Finished water is collected before the water enters the distribution system. This report describes the study design and percent recoveries of anthropogenic organic compounds (AOCs) with and without the addition of ascorbic acid to preserve water samples containing free chlorine. The percent recoveries were determined by using analytical results from a laboratory study conducted in 2004 by the USGS's National Water Quality Laboratory (NWQL) and from data collected during 2004-06 for a field study currently (2008) being conducted by the USGS's NAWQA Program. The laboratory study was designed to determine if preserving samples with ascorbic acid (quenching samples) adversely affects analytical performance under controlled conditions. During the laboratory study, eight samples of reagent water were spiked for each of five analytical schedules evaluated. Percent recoveries from these samples were then compared in two ways: (1) four quenched reagent spiked samples analyzed on day 0 were compared with four quenched reagent spiked samples analyzed on day 7 or 14, and (2) the combined eight quenched reagent spiked samples analyzed on day 0, 7, or 14 were compared with eight laboratory reagent spikes (LRSs). Percent recoveries from the quenched reagent spiked samples that were analyzed at two different times (day 0 and day 7 or 14) can be used to determine the stability of the quenched samples held for an amount of time representative of the normal amount of time between sample collection and analysis. The comparison between the quenched reagent spiked samples and the LRSs can be used to determine if quenching samples adversely affects the analytical performance under controlled conditions. The field study began in 2004 and is continuing today (February 2008) to characterize the effect of quenching on field-matrix spike recoveries and to better understand the potential oxidation and transformation of 277 AOCs. Three types of samples were collected from 11 NAWQA Study Units across the Nation: (1) quenched finished-water samples (not spiked), (2) quenched finished-water spiked samples, and (3) nonquenched finished-water spiked samples. Percent recoveries of AOCs in quenched and nonquenched finished-water spiked samples collected during 2004-06 are presented. Comparisons of percent recoveries between quenched and nonquenched spiked samples can be used to show how quenching affects finished-water samples. A maximum of 6 surface-water and 7 ground-water quenched finished-water spiked samples paired with nonquenched finished-water spiked samples were analyzed. Analytical results for the field study are presented in two ways: (1) by surface-water supplies or ground-water supplies, and (2) by use (or source) group category for surface-water and ground-water supplies. Graphical representations of percent recoveries for the quenched and nonquenched finished-water spiked samples also are presented.
Porter, Charlotte A; Bradley, Kevin M; McGowan, Daniel R
2018-05-01
The aim of this study was to verify, with a large dataset of 1394 Cr-EDTA glomerular filtration rate (GFR) studies, the equivalence of slope-intercept and single-sample GFR. Raw data from 1394 patient studies were used to calculate four-sample slope-intercept GFR in addition to four individual single-sample GFR values (blood samples taken at 90, 150, 210 and 270 min after injection). The percentage differences between the four-sample slope-intercept and each of the single-sample GFR values were calculated, to identify the optimum single-sample time point. Having identified the optimum time point, the percentage difference between the slope-intercept and optimal single-sample GFR was calculated across a range of GFR values to investigate whether there was a GFR value below which the two methodologies cannot be considered equivalent. It was found that the lowest percentage difference between slope-intercept and single-sample GFR was for the third blood sample, taken at 210 min after injection. The median percentage difference was 2.5% and only 6.9% of patient studies had a percentage difference greater than 10%. Above a GFR value of 30 ml/min/1.73 m, the median percentage difference between the slope-intercept and optimal single-sample GFR values was below 10%, and so it was concluded that, above this value, the two techniques are sufficiently equivalent. This study supports the recommendation of performing single-sample GFR measurements for GFRs greater than 30 ml/min/1.73 m.
Formaldehyde Exposures in a University Anatomy Laboratory
NASA Astrophysics Data System (ADS)
Winkler, Kyle William
Air sampling studies were conducted within a university anatomical laboratory during the embalmment of a cadaver in order to determine if dangerous concentrations of formaldehyde existed. Three air sampling studies were conducted in the anatomical laboratory on three separate days that a cadaver was being embalmed. Samples were collected and analyzed using the Occupational Safety and Health Administration (OSHA) Sampling and Analytical Methods: Method 52. Each air sampling study sampled for short term exposure limit (STEL) and time weighted mean (TWA) breathing zone formaldehyde concentrations as well as area TWA formaldehyde concentrations. A personal aldehyde monitor was also used in each air sampling study to sample for breathing zone formaldehyde concentrations. Measured TWA mean exposures to formaldehyde ranged from 0.15--1.3 parts per million (ppm), STEL formaldehyde exposures ranged from 0.019--0.64 ppm, and eight-hour TWAs ranged from 0.03 to 3.6 ppm. All 8-hour TWA formaldehyde concentrations sampled in the anatomy laboratory during an embalmment were less than the permissible exposure limit (PEL) required by OSHA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kyle, Jennifer E.; Casey, Cameron P.; Stratton, Kelly G.
The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules weremore » identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.« less
Hatzell, H.H.; Oaksford, E.T.; Asbury, C.E.
1995-01-01
The implementation of design guidelines for the National Water-Quality Assessment (NAWQA) Program has resulted in the development of new sampling procedures and the modification of existing procedures commonly used in the Water Resources Division of the U.S. Geological Survey. The Georgia-Florida Coastal Plain (GAFL) study unit began the intensive data collection phase of the program in October 1992. This report documents the implementation of the NAWQA guidelines by describing the sampling design and procedures for collecting surface-water samples in the GAFL study unit in 1993. This documentation is provided for agencies that use water-quality data and for future study units that will be entering the intensive phase of data collection. The sampling design is intended to account for large- and small-scale spatial variations, and temporal variations in water quality for the study area. Nine fixed sites were selected in drainage basins of different sizes and different land-use characteristics located in different land-resource provinces. Each of the nine fixed sites was sampled regularly for a combination of six constituent groups composed of physical and chemical constituents: field measurements, major ions and metals, nutrients, organic carbon, pesticides, and suspended sediments. Some sites were also sampled during high-flow conditions and storm events. Discussion of the sampling procedure is divided into three phases: sample collection, sample splitting, and sample processing. A cone splitter was used to split water samples for the analysis of the sampling constituent groups except organic carbon from approximately nine liters of stream water collected at four fixed sites that were sampled intensively. An example of the sample splitting schemes designed to provide the sample volumes required for each sample constituent group is described in detail. Information about onsite sample processing has been organized into a flowchart that describes a pathway for each of the constituent groups.
Why sampling scheme matters: the effect of sampling scheme on landscape genetic results
Michael K. Schwartz; Kevin S. McKelvey
2008-01-01
There has been a recent trend in genetic studies of wild populations where researchers have changed their sampling schemes from sampling pre-defined populations to sampling individuals uniformly across landscapes. This reflects the fact that many species under study are continuously distributed rather than clumped into obvious "populations". Once individual...
Mathany, Timothy M.
2017-03-09
The Priority Basin Project (PBP) of the Groundwater Ambient Monitoring and Assessment (GAMA) program was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey in cooperation with the California State Water Resources Control Board. From 2004 through 2012, the GAMA-PBP collected samples and assessed the quality of groundwater resources that supply public drinking water in 35 study units across the State. Selected sites in each study unit were sampled again approximately 3 years after initial sampling as part of an assessment of temporal trends in water quality by the GAMA-PBP. Twelve of the study units, initially sampled during 2006–11 (initial sampling period) and sampled a second time during 2008–13 (trend sampling period) to assess temporal trends, are the subject of this report.The initial sampling was designed to provide a spatially unbiased assessment of the quality of untreated groundwater used for public water supplies in the 12 study units. In these study units, 550 sampling sites were selected by using a spatially distributed, randomized, grid-based method to provide spatially unbiased representation of the areas assessed (grid sites, also called “status sites”). After the initial sampling period, 76 of the previously sampled status sites (approximately 10 percent in each study unit) were randomly selected for trend sampling (“trend sites”). The 12 study units sampled both during the initial sampling and during the trend sampling period were distributed among 6 hydrogeologic provinces: Coastal (Northern and Southern), Transverse Ranges and Selected Peninsular Ranges, Klamath, Modoc Plateau and Cascades, and Sierra Nevada Hydrogeologic Provinces. For the purposes of this trend report, the six hydrogeologic provinces were grouped into two hydrogeologic regions based on location: Coastal and Mountain.The groundwater samples were analyzed for a number of synthetic organic constituents (volatile organic compounds, pesticides, and pesticide degradates), constituents of special interest (perchlorate and 1,2,3-trichloropropane), and natural inorganic constituents (nutrients, major and minor ions, and trace elements). Isotopic tracers (tritium, carbon-14, and stable isotopes of hydrogen and oxygen in water) also were measured to help identify processes affecting groundwater quality and the sources and ages of the sampled groundwater. More than 200 constituents and water-quality indicators were measured during the trend sampling period.Quality-control samples (blanks, replicates, matrix-spikes, and surrogate compounds) were collected at about one-third of the trend sites, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. On the basis of detections in laboratory and field blank samples collected by GAMA-PBP study units, including the 12 study units presented here, reporting levels for some groundwater results were adjusted in this report. Differences between replicate samples were mostly within acceptable ranges, indicating low variability in analytical results. Matrix-spike recoveries were largely within the acceptable range (70 to 130 percent).This study did not attempt to evaluate the quality of water delivered to consumers. After withdrawal, groundwater used for drinking water typically is treated, disinfected, and blended with other waters to achieve acceptable water quality. The comparison benchmarks used in this report apply to treated water that is served to the consumer, not to untreated groundwater. To provide some context for the results, however, concentrations of constituents measured in these groundwater samples were compared with benchmarks established by the U.S. Environmental Protection Agency and the State of California. Comparisons between data collected for this study and benchmarks for drinking water are for illustrative purposes only and are not indicative of compliance or non-compliance with those benchmarks.Most organic constituents that were detected in groundwater samples from the trend sites were found at concentrations less than health-based benchmarks. One volatile organic compound—perchloroethene—was detected at a concentration greater than the health-based benchmark in samples from one trend site during the initial and trend sampling periods. Chloroform was detected in at least 10 percent of the samples at trend sites in both sampling periods. Methyl tert-butyl ether was detected in samples from more than 10 percent of the trend sites during the initial sampling period. No pesticide or pesticide degradate was detected in greater than 10 percent of the samples from trend sites or at concentrations greater than their health-based benchmarks during either sampling period. Nutrients were not detected at concentrations greater than their health-based benchmarks during either sampling period.Most detections of major ions and trace elements in samples from trend sites were less than health-based benchmarks during both sampling periods. Arsenic and boron each were detected at concentrations greater than the health-based benchmark in samples from four trend sites during the initial and trend sampling periods. Molybdenum was detected in samples from four trend sites at concentrations greater than the health-based benchmark during both sampling periods. Samples from two of these trend sites had similar molybdenum concentrations, and two had substantially different concentrations during the initial and trend sampling periods. Uranium was detected at a concentration greater than the health-based benchmark only at two trend sites.
NASA Technical Reports Server (NTRS)
Tomberlin, T. J.
1985-01-01
Research studies of residents' responses to noise consist of interviews with samples of individuals who are drawn from a number of different compact study areas. The statistical techniques developed provide a basis for those sample design decisions. These techniques are suitable for a wide range of sample survey applications. A sample may consist of a random sample of residents selected from a sample of compact study areas, or in a more complex design, of a sample of residents selected from a sample of larger areas (e.g., cities). The techniques may be applied to estimates of the effects on annoyance of noise level, numbers of noise events, the time-of-day of the events, ambient noise levels, or other factors. Methods are provided for determining, in advance, how accurately these effects can be estimated for different sample sizes and study designs. Using a simple cost function, they also provide for optimum allocation of the sample across the stages of the design for estimating these effects. These techniques are developed via a regression model in which the regression coefficients are assumed to be random, with components of variance associated with the various stages of a multi-stage sample design.
An internal pilot design for prospective cancer screening trials with unknown disease prevalence.
Brinton, John T; Ringham, Brandy M; Glueck, Deborah H
2015-10-13
For studies that compare the diagnostic accuracy of two screening tests, the sample size depends on the prevalence of disease in the study population, and on the variance of the outcome. Both parameters may be unknown during the design stage, which makes finding an accurate sample size difficult. To solve this problem, we propose adapting an internal pilot design. In this adapted design, researchers will accrue some percentage of the planned sample size, then estimate both the disease prevalence and the variances of the screening tests. The updated estimates of the disease prevalence and variance are used to conduct a more accurate power and sample size calculation. We demonstrate that in large samples, the adapted internal pilot design produces no Type I inflation. For small samples (N less than 50), we introduce a novel adjustment of the critical value to control the Type I error rate. We apply the method to two proposed prospective cancer screening studies: 1) a small oral cancer screening study in individuals with Fanconi anemia and 2) a large oral cancer screening trial. Conducting an internal pilot study without adjusting the critical value can cause Type I error rate inflation in small samples, but not in large samples. An internal pilot approach usually achieves goal power and, for most studies with sample size greater than 50, requires no Type I error correction. Further, we have provided a flexible and accurate approach to bound Type I error below a goal level for studies with small sample size.
ERIC Educational Resources Information Center
Mireault, Gina; Rooney, Siri; Kouwenhoven, Kristen; Hannan, Carolyn
2008-01-01
Studies have repeatedly shown that oppositional behavior is linked to anxiety in clinical samples of children. This study explored whether these variables were similarly related in nonclinical samples of elementary and middle school students (N = 302). Despite greater self-reported oppositional behavior among boys in these samples, anxiety…
ERIC Educational Resources Information Center
Collins, Kathleen M. T.; Onwuegbuzie, Anthony J.; Jiao, Qun G.
2007-01-01
A sequential design utilizing identical samples was used to classify mixed methods studies via a two-dimensional model, wherein sampling designs were grouped according to the time orientation of each study's components and the relationship of the qualitative and quantitative samples. A quantitative analysis of 121 studies representing nine fields…
Guo, Jiin-Huarng; Luh, Wei-Ming
2009-05-01
When planning a study, sample size determination is one of the most important tasks facing the researcher. The size will depend on the purpose of the study, the cost limitations, and the nature of the data. By specifying the standard deviation ratio and/or the sample size ratio, the present study considers the problem of heterogeneous variances and non-normality for Yuen's two-group test and develops sample size formulas to minimize the total cost or maximize the power of the test. For a given power, the sample size allocation ratio can be manipulated so that the proposed formulas can minimize the total cost, the total sample size, or the sum of total sample size and total cost. On the other hand, for a given total cost, the optimum sample size allocation ratio can maximize the statistical power of the test. After the sample size is determined, the present simulation applies Yuen's test to the sample generated, and then the procedure is validated in terms of Type I errors and power. Simulation results show that the proposed formulas can control Type I errors and achieve the desired power under the various conditions specified. Finally, the implications for determining sample sizes in experimental studies and future research are discussed.
NASA Astrophysics Data System (ADS)
Voss, Sebastian; Zimmermann, Beate; Zimmermann, Alexander
2016-04-01
In the last three decades, an increasing number of studies analyzed spatial patterns in throughfall to investigate the consequences of rainfall redistribution for biogeochemical and hydrological processes in forests. In the majority of cases, variograms were used to characterize the spatial properties of the throughfall data. The estimation of the variogram from sample data requires an appropriate sampling scheme: most importantly, a large sample and an appropriate layout of sampling locations that often has to serve both variogram estimation and geostatistical prediction. While some recommendations on these aspects exist, they focus on Gaussian data and high ratios of the variogram range to the extent of the study area. However, many hydrological data, and throughfall data in particular, do not follow a Gaussian distribution. In this study, we examined the effect of extent, sample size, sampling design, and calculation methods on variogram estimation of throughfall data. For our investigation, we first generated non-Gaussian random fields based on throughfall data with heavy outliers. Subsequently, we sampled the fields with three extents (plots with edge lengths of 25 m, 50 m, and 100 m), four common sampling designs (two grid-based layouts, transect and random sampling), and five sample sizes (50, 100, 150, 200, 400). We then estimated the variogram parameters by method-of-moments and residual maximum likelihood. Our key findings are threefold. First, the choice of the extent has a substantial influence on the estimation of the variogram. A comparatively small ratio of the extent to the correlation length is beneficial for variogram estimation. Second, a combination of a minimum sample size of 150, a design that ensures the sampling of small distances and variogram estimation by residual maximum likelihood offers a good compromise between accuracy and efficiency. Third, studies relying on method-of-moments based variogram estimation may have to employ at least 200 sampling points for reliable variogram estimates. These suggested sample sizes exceed the numbers recommended by studies dealing with Gaussian data by up to 100 %. Given that most previous throughfall studies relied on method-of-moments variogram estimation and sample sizes << 200, our current knowledge about throughfall spatial variability stands on shaky ground.
NASA Astrophysics Data System (ADS)
Voss, Sebastian; Zimmermann, Beate; Zimmermann, Alexander
2016-09-01
In the last decades, an increasing number of studies analyzed spatial patterns in throughfall by means of variograms. The estimation of the variogram from sample data requires an appropriate sampling scheme: most importantly, a large sample and a layout of sampling locations that often has to serve both variogram estimation and geostatistical prediction. While some recommendations on these aspects exist, they focus on Gaussian data and high ratios of the variogram range to the extent of the study area. However, many hydrological data, and throughfall data in particular, do not follow a Gaussian distribution. In this study, we examined the effect of extent, sample size, sampling design, and calculation method on variogram estimation of throughfall data. For our investigation, we first generated non-Gaussian random fields based on throughfall data with large outliers. Subsequently, we sampled the fields with three extents (plots with edge lengths of 25 m, 50 m, and 100 m), four common sampling designs (two grid-based layouts, transect and random sampling) and five sample sizes (50, 100, 150, 200, 400). We then estimated the variogram parameters by method-of-moments (non-robust and robust estimators) and residual maximum likelihood. Our key findings are threefold. First, the choice of the extent has a substantial influence on the estimation of the variogram. A comparatively small ratio of the extent to the correlation length is beneficial for variogram estimation. Second, a combination of a minimum sample size of 150, a design that ensures the sampling of small distances and variogram estimation by residual maximum likelihood offers a good compromise between accuracy and efficiency. Third, studies relying on method-of-moments based variogram estimation may have to employ at least 200 sampling points for reliable variogram estimates. These suggested sample sizes exceed the number recommended by studies dealing with Gaussian data by up to 100 %. Given that most previous throughfall studies relied on method-of-moments variogram estimation and sample sizes ≪200, currently available data are prone to large uncertainties.
van Hanegem, Nehalennia; Prins, Marileen M C; Bongers, Marlies Y; Opmeer, Brent C; Sahota, Daljit Singh; Mol, Ben Willem J; Timmermans, Anne
2016-02-01
Postmenopausal bleeding (PMB) can be the first sign of endometrial cancer. In case of thickened endometrium, endometrial sampling is often used in these women. In this systematic review, we studied the accuracy of endometrial sampling for the diagnoses of endometrial cancer, atypical hyperplasia and endometrial disease (endometrial pathology, including benign polyps). We systematically searched the literature for studies comparing the results of endometrial sampling in women with postmenopausal bleeding with two different reference standards: blind dilatation and curettage (D&C) and hysteroscopy with histology. We assessed the quality of the detected studies by the QUADAS-2 tool. For each included study, we calculated the fraction of women in whom endometrial sampling failed. Furthermore, we extracted numbers of cases of endometrial cancer, atypical hyperplasia and endometrial disease that were identified or missed by endometrial sampling. We detected 12 studies reporting on 1029 women with postmenopausal bleeding: five studies with dilatation and curettage (D&C) and seven studies with hysteroscopy as a reference test. The weighted sensitivity of endometrial sampling with D&C as a reference for the diagnosis of endometrial cancer was 100% (range 100-100%) and 92% (71-100) for the diagnosis of atypical hyperplasia. Only one study reported sensitivity for endometrial disease, which was 76%. When hysteroscopy was used as a reference, weighted sensitivities of endometrial sampling were 90% (range 50-100), 82% (range 56-94) and 39% (21-69) for the diagnosis of endometrial cancer, atypical hyperplasia and endometrial disease, respectively. For all diagnosis studied and the reference test used, specificity was 98-100%. The weighted failure rate of endometrial sampling was 11% (range 1-53%), while insufficient samples were found in 31% (range 7-76%). In these women with insufficient or failed samples, an endometrial (pre) cancer was found in 7% (range 0-18%). In women with postmenopausal bleeding, the sensitivity of endometrial sampling to detect endometrial cancer and especially atypical hyperplasia and endometrial disease, including endometrial polyps, is lower than previously thought. Therefore, further diagnostic work-up for focal pathology is warranted, after a benign result of endometrial sampling. Copyright © 2015. Published by Elsevier Ireland Ltd.
Nelson, Jennifer C.; Marsh, Tracey; Lumley, Thomas; Larson, Eric B.; Jackson, Lisa A.; Jackson, Michael
2014-01-01
Objective Estimates of treatment effectiveness in epidemiologic studies using large observational health care databases may be biased due to inaccurate or incomplete information on important confounders. Study methods that collect and incorporate more comprehensive confounder data on a validation cohort may reduce confounding bias. Study Design and Setting We applied two such methods, imputation and reweighting, to Group Health administrative data (full sample) supplemented by more detailed confounder data from the Adult Changes in Thought study (validation sample). We used influenza vaccination effectiveness (with an unexposed comparator group) as an example and evaluated each method’s ability to reduce bias using the control time period prior to influenza circulation. Results Both methods reduced, but did not completely eliminate, the bias compared with traditional effectiveness estimates that do not utilize the validation sample confounders. Conclusion Although these results support the use of validation sampling methods to improve the accuracy of comparative effectiveness findings from healthcare database studies, they also illustrate that the success of such methods depends on many factors, including the ability to measure important confounders in a representative and large enough validation sample, the comparability of the full sample and validation sample, and the accuracy with which data can be imputed or reweighted using the additional validation sample information. PMID:23849144
Xun-Ping, W; An, Z
2017-07-27
Objective To optimize and simplify the survey method of Oncomelania hupensis snails in marshland endemic regions of schistosomiasis, so as to improve the precision, efficiency and economy of the snail survey. Methods A snail sampling strategy (Spatial Sampling Scenario of Oncomelania based on Plant Abundance, SOPA) which took the plant abundance as auxiliary variable was explored and an experimental study in a 50 m×50 m plot in a marshland in the Poyang Lake region was performed. Firstly, the push broom surveyed data was stratified into 5 layers by the plant abundance data; then, the required numbers of optimal sampling points of each layer through Hammond McCullagh equation were calculated; thirdly, every sample point in the line with the Multiple Directional Interpolation (MDI) placement scheme was pinpointed; and finally, the comparison study among the outcomes of the spatial random sampling strategy, the traditional systematic sampling method, the spatial stratified sampling method, Sandwich spatial sampling and inference and SOPA was performed. Results The method (SOPA) proposed in this study had the minimal absolute error of 0.213 8; and the traditional systematic sampling method had the largest estimate, and the absolute error was 0.924 4. Conclusion The snail sampling strategy (SOPA) proposed in this study obtains the higher estimation accuracy than the other four methods.
Guidelines and sample protocol for sampling forest gaps.
J.R. Runkle
1992-01-01
A protocol for sampling forest canopy gaps is presented. Methods used in published gap studies are reviewed. The sample protocol will be useful in developing a broader understanding of forest structure and dynamics through comparative studies across different forest ecosystems.
NASA Astrophysics Data System (ADS)
Ander, Louise; Lark, Murray; Smedley, Pauline; Watts, Michael; Hamilton, Elliott; Fletcher, Tony; Crabbe, Helen; Close, Rebecca; Studden, Mike; Leonardi, Giovanni
2015-04-01
Random sampling design is optimal in order to be able to assess outcomes, such as the mean of a given variable across an area. However, this optimal sampling design may be compromised to an unknown extent by unavoidable real-world factors: the extent to which the study design can still be considered random, and the influence this may have on the choice of appropriate statistical data analysis is examined in this work. We take a study which relied on voluntary participation for the sampling of private water tap chemical composition in England, UK. This study was designed and implemented as a categorical, randomised study. The local geological classes were grouped into 10 types, which were considered to be most important in likely effects on groundwater chemistry (the source of all the tap waters sampled). Locations of the users of private water supplies were made available to the study group from the Local Authority in the area. These were then assigned, based on location, to geological groups 1 to 10 and randomised within each group. However, the permission to collect samples then required active, voluntary participation by householders and thus, unlike many environmental studies, could not always follow the initial sample design. Impediments to participation ranged from 'willing but not available' during the designated sampling period, to a lack of response to requests to sample (assumed to be wholly unwilling or unable to participate). Additionally, a small number of unplanned samples were collected via new participants making themselves known to the sampling teams, during the sampling period. Here we examine the impact this has on the 'random' nature of the resulting data distribution, by comparison with the non-participating known supplies. We consider the implications this has on choice of statistical analysis methods to predict values and uncertainty at un-sampled locations.
Does Cognitive Function Increase over Time in the Healthy Elderly?
de Rotrou, Jocelyne; Wu, Ya-Huei; Mabire, Jean-Bernard; Moulin, Florence; de Jong, Laura W.; Rigaud, Anne-Sophie; Hanon, Olivier; Vidal, Jean-Sébastien
2013-01-01
Background In dementia screening, most studies have focused on early cognitive impairment by comparing patients suffering from mild dementia or mild cognitive impairment with normal subjects. Few studies have focused on modifications over time of the cognitive function in the healthy elderly. The objective of the present study was to analyze the cognitive function changes of two different samples, born > 15 years apart. Method A first sample of 204 cognitively normal participants was recruited in the memory clinic of Broca hospital between 1991 and 1997. A second sample of 177 cognitively normal participants was recruited in 2008–2009 in the same institution. Both samples were from the same districts of Paris and were assessed with the same neuropsychological test battery. Mean cognitive test scores were compared between 1991 and 2008 samples, between < 80 years old and ≥ 80 years old in 1991 and 2008 samples, and finally between subjects < 80 year old of 1991 sample and subjects ≥ 80 years old of the 2008 sample. Means were compared with T-tests stratified on gender, age-groups and educational level. Results Cognitive scores were significantly higher in the 2008 sample. Participants < 80 years old outperformed those ≥ 80 in both samples. However, participants < 80 years old in 1991 sample and subjects ≥ 80 in the 2008 sample, born on average in 1923, performed mostly identically. Conclusion This study showed a significant increase of cognitive scores over time. Further, contemporary octogenarians in the later sample performed like septuagenarians in the former sample. These findings might be consistent with the increase in life expectancy and life span in good health. The study highlights the necessity to take into account factors which may contaminate and artificially inflate the age-related differences in favor of younger to the older adults. PMID:24244332
Work Sampling Study of an Engineering Professor during a Regular Contract Period
ERIC Educational Resources Information Center
Brink, Jan; McDonald, Dale B.
2015-01-01
Work sampling is a technique that has been employed in industry and fields such as healthcare for some time. It is a powerful technique, and an alternative to conventional stop watch time studies, used by industrial engineers to focus upon random work sampling observations. This study applies work sampling to the duties performed by an individual…
Optical Methods for Identifying Hard Clay Core Samples During Petrophysical Studies
NASA Astrophysics Data System (ADS)
Morev, A. V.; Solovyeva, A. V.; Morev, V. A.
2018-01-01
X-ray phase analysis of the general mineralogical composition of core samples from one of the West Siberian fields was performed. Electronic absorption spectra of the clay core samples with an added indicator were studied. The speed and availability of applying the two methods in petrophysical laboratories during sample preparation for standard and special studies were estimated.
Composite Sampling Approaches for Bacillus anthracis Surrogate Extracted from Soil
France, Brian; Bell, William; Chang, Emily; Scholten, Trudy
2015-01-01
Any release of anthrax spores in the U.S. would require action to decontaminate the site and restore its use and operations as rapidly as possible. The remediation activity would require environmental sampling, both initially to determine the extent of contamination (hazard mapping) and post-decon to determine that the site is free of contamination (clearance sampling). Whether the spore contamination is within a building or outdoors, collecting and analyzing what could be thousands of samples can become the factor that limits the pace of restoring operations. To address this sampling and analysis bottleneck and decrease the time needed to recover from an anthrax contamination event, this study investigates the use of composite sampling. Pooling or compositing of samples is an established technique to reduce the number of analyses required, and its use for anthrax spore sampling has recently been investigated. However, use of composite sampling in an anthrax spore remediation event will require well-documented and accepted methods. In particular, previous composite sampling studies have focused on sampling from hard surfaces; data on soil sampling are required to extend the procedure to outdoor use. Further, we must consider whether combining liquid samples, thus increasing the volume, lowers the sensitivity of detection and produces false negatives. In this study, methods to composite bacterial spore samples from soil are demonstrated. B. subtilis spore suspensions were used as a surrogate for anthrax spores. Two soils (Arizona Test Dust and sterilized potting soil) were contaminated and spore recovery with composites was shown to match individual sample performance. Results show that dilution can be overcome by concentrating bacterial spores using standard filtration methods. This study shows that composite sampling can be a viable method of pooling samples to reduce the number of analysis that must be performed during anthrax spore remediation. PMID:26714315
Sampling designs for HIV molecular epidemiology with application to Honduras.
Shepherd, Bryan E; Rossini, Anthony J; Soto, Ramon Jeremias; De Rivera, Ivette Lorenzana; Mullins, James I
2005-11-01
Proper sampling is essential to characterize the molecular epidemiology of human immunodeficiency virus (HIV). HIV sampling frames are difficult to identify, so most studies use convenience samples. We discuss statistically valid and feasible sampling techniques that overcome some of the potential for bias due to convenience sampling and ensure better representation of the study population. We employ a sampling design called stratified cluster sampling. This first divides the population into geographical and/or social strata. Within each stratum, a population of clusters is chosen from groups, locations, or facilities where HIV-positive individuals might be found. Some clusters are randomly selected within strata and individuals are randomly selected within clusters. Variation and cost help determine the number of clusters and the number of individuals within clusters that are to be sampled. We illustrate the approach through a study designed to survey the heterogeneity of subtype B strains in Honduras.
Preanalytical Errors in Hematology Laboratory- an Avoidable Incompetence.
HarsimranKaur, Vikram Narang; Selhi, Pavneet Kaur; Sood, Neena; Singh, Aminder
2016-01-01
Quality assurance in the hematology laboratory is a must to ensure laboratory users of reliable test results with high degree of precision and accuracy. Even after so many advances in hematology laboratory practice, pre-analytical errors remain a challenge for practicing pathologists. This study was undertaken with an objective to evaluate the types and frequency of preanalytical errors in hematology laboratory of our center. All the samples received in the Hematology Laboratory of Dayanand Medical College and Hospital, Ludhiana, India over a period of one year (July 2013-July 2014) were included in the study and preanalytical variables like clotted samples, quantity not sufficient, wrong sample, without label, wrong label were studied. Of 471,006 samples received in the laboratory, preanalytical errors, as per the above mentioned categories was found in 1802 samples. The most common error was clotted samples (1332 samples, 0.28% of the total samples) followed by quantity not sufficient (328 sample, 0.06%), wrong sample (96 samples, 0.02%), without label (24 samples, 0.005%) and wrong label (22 samples, 0.005%). Preanalytical errors are frequent in laboratories and can be corrected by regular analysis of the variables involved. Rectification can be done by regular education of the staff.
CTEPP STANDARD OPERATING PROCEDURE FOR PACKING AND SHIPPING STUDY SAMPLES (SOP-3.11)
This SOP describes the methods for packing and shipping study samples. These methods are for packing and shipping biological and environmental samples. The methods have been tested and used in the previous pilot studies.
NASA Astrophysics Data System (ADS)
Sydoff, Marie; Stenström, Kristina
2010-04-01
The Department of Physics at Lund University is participating in a European Union project called EUMAPP (European Union Microdose AMS Partnership Programme), in which sample preparation and accelerator mass spectrometry (AMS) measurements of biological samples from microdosing studies have been made. This paper describes a simplified method of converting biological samples to solid graphite for 14C analysis with AMS. The method is based on online combustion of the samples, and reduction of CO 2 in septa-sealed vials. The septa-sealed vials and disposable materials are used to eliminate sample cross-contamination. Measurements of ANU and Ox I standards show deviations of 2% and 3%, respectively, relative to reference values. This level of accuracy is sufficient for biological samples from microdosing studies. Since the method has very few handling steps from sample to graphite, the risk of failure during the sample preparation process is minimized, making the method easy to use in routine preparation of samples.
FIELD-SCALE STUDIES: HOW DOES SOIL SAMPLE PRETREATMENT AFFECT REPRESENTATIVENESS ? (ABSTRACT)
Samples from field-scale studies are very heterogeneous and can contain large soil and rock particles. Oversize materials are often removed before chemical analysis of the soil samples because it is not practical to include these materials. Is the extracted sample representativ...
FIELD-SCALE STUDIES: HOW DOES SOIL SAMPLE PRETREATMENT AFFECT REPRESENTATIVENESS?
Samples from field-scale studies are very heterogeneous and can contain large soil and rock particles. Oversize materials are often removed before chemical analysis of the soil samples because it is not practical to include these materials. Is the extracted sample representativ...
What is the optimum sample size for the study of peatland testate amoeba assemblages?
Mazei, Yuri A; Tsyganov, Andrey N; Esaulov, Anton S; Tychkov, Alexander Yu; Payne, Richard J
2017-10-01
Testate amoebae are widely used in ecological and palaeoecological studies of peatlands, particularly as indicators of surface wetness. To ensure data are robust and comparable it is important to consider methodological factors which may affect results. One significant question which has not been directly addressed in previous studies is how sample size (expressed here as number of Sphagnum stems) affects data quality. In three contrasting locations in a Russian peatland we extracted samples of differing size, analysed testate amoebae and calculated a number of widely-used indices: species richness, Simpson diversity, compositional dissimilarity from the largest sample and transfer function predictions of water table depth. We found that there was a trend for larger samples to contain more species across the range of commonly-used sample sizes in ecological studies. Smaller samples sometimes failed to produce counts of testate amoebae often considered minimally adequate. It seems likely that analyses based on samples of different sizes may not produce consistent data. Decisions about sample size need to reflect trade-offs between logistics, data quality, spatial resolution and the disturbance involved in sample extraction. For most common ecological applications we suggest that samples of more than eight Sphagnum stems are likely to be desirable. Copyright © 2017 Elsevier GmbH. All rights reserved.
Using random telephone sampling to recruit generalizable samples for family violence studies.
Slep, Amy M Smith; Heyman, Richard E; Williams, Mathew C; Van Dyke, Cheryl E; O'Leary, Susan G
2006-12-01
Convenience sampling methods predominate in recruiting for laboratory-based studies within clinical and family psychology. The authors used random digit dialing (RDD) to determine whether they could feasibly recruit generalizable samples for 2 studies (a parenting study and an intimate partner violence study). RDD screen response rate was 42-45%; demographics matched those in the 2000 U.S. Census, with small- to medium-sized differences on race, age, and income variables. RDD respondents who qualified for, but did not participate in, the laboratory study of parents showed small differences on income, couple conflicts, and corporal punishment. Time and cost are detailed, suggesting that RDD may be a feasible, effective method by which to recruit more generalizable samples for in-laboratory studies of family violence when those studies have sufficient resources. (c) 2006 APA, all rights reserved.
Options in Extraterrestrial Sample Handling and Study
NASA Technical Reports Server (NTRS)
Papanastassiou, Dimitri A.
2000-01-01
This presentation mentions important service functions such as: sample preservation, hazard assessment, and handling. It also discuss how preliminary examination of samples is necessary for sample hazard assessment and for sample allocations. Clean facilities and clean sample handling are required. Conflicts, cross contamination issues will be present and need to be resolved. Extensive experience is available for extraterrestrial samples and must be sought and applied. Extensive experience is available in studies of pathogenicity and must be sought and applied as necessary. Advisory and oversight structures must also be in place
Developing Sampling Frame for Case Study: Challenges and Conditions
ERIC Educational Resources Information Center
Ishak, Noriah Mohd; Abu Bakar, Abu Yazid
2014-01-01
Due to statistical analysis, the issue of random sampling is pertinent to any quantitative study. Unlike quantitative study, the elimination of inferential statistical analysis, allows qualitative researchers to be more creative in dealing with sampling issue. Since results from qualitative study cannot be generalized to the bigger population,…
40 CFR 761.392 - Preparing validation study samples.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Preparing validation study samples..., AND USE PROHIBITIONS Comparison Study for Validating a New Performance-Based Decontamination Solvent Under § 761.79(d)(4) § 761.392 Preparing validation study samples. (a)(1) To validate a procedure to...
40 CFR 761.392 - Preparing validation study samples.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Preparing validation study samples..., AND USE PROHIBITIONS Comparison Study for Validating a New Performance-Based Decontamination Solvent Under § 761.79(d)(4) § 761.392 Preparing validation study samples. (a)(1) To validate a procedure to...
Effects of sample size on estimates of population growth rates calculated with matrix models.
Fiske, Ian J; Bruna, Emilio M; Bolker, Benjamin M
2008-08-28
Matrix models are widely used to study the dynamics and demography of populations. An important but overlooked issue is how the number of individuals sampled influences estimates of the population growth rate (lambda) calculated with matrix models. Even unbiased estimates of vital rates do not ensure unbiased estimates of lambda-Jensen's Inequality implies that even when the estimates of the vital rates are accurate, small sample sizes lead to biased estimates of lambda due to increased sampling variance. We investigated if sampling variability and the distribution of sampling effort among size classes lead to biases in estimates of lambda. Using data from a long-term field study of plant demography, we simulated the effects of sampling variance by drawing vital rates and calculating lambda for increasingly larger populations drawn from a total population of 3842 plants. We then compared these estimates of lambda with those based on the entire population and calculated the resulting bias. Finally, we conducted a review of the literature to determine the sample sizes typically used when parameterizing matrix models used to study plant demography. We found significant bias at small sample sizes when survival was low (survival = 0.5), and that sampling with a more-realistic inverse J-shaped population structure exacerbated this bias. However our simulations also demonstrate that these biases rapidly become negligible with increasing sample sizes or as survival increases. For many of the sample sizes used in demographic studies, matrix models are probably robust to the biases resulting from sampling variance of vital rates. However, this conclusion may depend on the structure of populations or the distribution of sampling effort in ways that are unexplored. We suggest more intensive sampling of populations when individual survival is low and greater sampling of stages with high elasticities.
Forensic Tools to Track and Connect Physical Samples to Related Data
NASA Astrophysics Data System (ADS)
Molineux, A.; Thompson, A. C.; Baumgardner, R. W.
2016-12-01
Identifiers, such as local sample numbers, are critical to successfully connecting physical samples and related data. However, identifiers must be globally unique. The International Geo Sample Number (IGSN) generated when registering the sample in the System for Earth Sample Registration (SESAR) provides a globally unique alphanumeric code associated with basic metadata, related samples and their current physical storage location. When registered samples are published, users can link the figured samples to the basic metadata held at SESAR. The use cases we discuss include plant specimens from a Permian core, Holocene corals and derived powders, and thin sections with SEM stubs. Much of this material is now published. The plant taxonomic study from the core is a digital pdf and samples can be directly linked from the captions to the SESAR record. The study of stable isotopes from the corals is not yet digitally available, but individual samples are accessible. Full data and media records for both studies are located in our database where higher quality images, field notes, and section diagrams may exist. Georeferences permit mapping in current and deep time plate configurations. Several aspects emerged during this study. The first, ensure adequate and consistent details are registered with SESAR. Second, educate and encourage the researcher to obtain IGSNs. Third, publish the archive numbers, assigned prior to publication, alongside the IGSN. This provides access to further data through an Integrated Publishing Toolkit (IPT)/aggregators/or online repository databases, thus placing the initial sample in a much richer context for future studies. Fourth, encourage software developers to customize community software to extract data from a database and use it to register samples in bulk. This would improve workflow and provide a path for registration of large legacy collections.
Replicating studies in which samples of participants respond to samples of stimuli.
Westfall, Jacob; Judd, Charles M; Kenny, David A
2015-05-01
In a direct replication, the typical goal is to reproduce a prior experimental result with a new but comparable sample of participants in a high-powered replication study. Often in psychology, the research to be replicated involves a sample of participants responding to a sample of stimuli. In replicating such studies, we argue that the same criteria should be used in sampling stimuli as are used in sampling participants. Namely, a new but comparable sample of stimuli should be used to ensure that the original results are not due to idiosyncrasies of the original stimulus sample, and the stimulus sample must often be enlarged to ensure high statistical power. In support of the latter point, we discuss the fact that in experiments involving samples of stimuli, statistical power typically does not approach 1 as the number of participants goes to infinity. As an example of the importance of sampling new stimuli, we discuss the bygone literature on the risky shift phenomenon, which was almost entirely based on a single stimulus sample that was later discovered to be highly unrepresentative. We discuss the use of both resampled and expanded stimulus sets, that is, stimulus samples that include the original stimuli plus new stimuli. © The Author(s) 2015.
Ng, Ding-Quan; Liu, Shu-Wei; Lin, Yi-Pin
2018-09-15
In this study, a sampling campaign with a total of nine sampling events investigating lead in drinking water was conducted at 7 sampling locations in an old building with lead pipes in service in part of the building on the National Taiwan University campus. This study aims to assess the effectiveness of four different sampling methods, namely first draw sampling, sequential sampling, random daytime sampling and flush sampling, in lead contamination detection. In 3 out of the 7 sampling locations without lead pipe, lead could not be detected (<1.1 μg/L) in most samples regardless of the sampling methods. On the other hand, in the 4 sampling locations where lead pipes still existed, total lead concentrations >10 μg/L were consistently observed in 3 locations using any of the four sampling methods while the remaining location was identified to be contaminated using sequential sampling. High lead levels were consistently measured by the four sampling methods in the 3 locations in which particulate lead was either predominant or comparable to soluble lead. Compared to first draw and random daytime samplings, although flush sampling had a high tendency to reduce total lead in samples in lead-contaminated sites, the extent of lead reduction was location-dependent and not dependent on flush durations between 5 and 10 min. Overall, first draw sampling and random daytime sampling were reliable and effective in determining lead contamination in this study. Flush sampling could reveal the contamination if the extent is severe but tends to underestimate lead exposure risk. Copyright © 2018 Elsevier B.V. All rights reserved.
Nelson, Jennifer Clark; Marsh, Tracey; Lumley, Thomas; Larson, Eric B; Jackson, Lisa A; Jackson, Michael L
2013-08-01
Estimates of treatment effectiveness in epidemiologic studies using large observational health care databases may be biased owing to inaccurate or incomplete information on important confounders. Study methods that collect and incorporate more comprehensive confounder data on a validation cohort may reduce confounding bias. We applied two such methods, namely imputation and reweighting, to Group Health administrative data (full sample) supplemented by more detailed confounder data from the Adult Changes in Thought study (validation sample). We used influenza vaccination effectiveness (with an unexposed comparator group) as an example and evaluated each method's ability to reduce bias using the control time period before influenza circulation. Both methods reduced, but did not completely eliminate, the bias compared with traditional effectiveness estimates that do not use the validation sample confounders. Although these results support the use of validation sampling methods to improve the accuracy of comparative effectiveness findings from health care database studies, they also illustrate that the success of such methods depends on many factors, including the ability to measure important confounders in a representative and large enough validation sample, the comparability of the full sample and validation sample, and the accuracy with which the data can be imputed or reweighted using the additional validation sample information. Copyright © 2013 Elsevier Inc. All rights reserved.
[Respondent-Driven Sampling: a new sampling method to study visible and hidden populations].
Mantecón, Alejandro; Juan, Montse; Calafat, Amador; Becoña, Elisardo; Román, Encarna
2008-01-01
The paper introduces a variant of chain-referral sampling: respondent-driven sampling (RDS). This sampling method shows that methods based on network analysis can be combined with the statistical validity of standard probability sampling methods. In this sense, RDS appears to be a mathematical improvement of snowball sampling oriented to the study of hidden populations. However, we try to prove its validity with populations that are not within a sampling frame but can nonetheless be contacted without difficulty. The basics of RDS are explained through our research on young people (aged 14 to 25) who go clubbing, consume alcohol and other drugs, and have sex. Fieldwork was carried out between May and July 2007 in three Spanish regions: Baleares, Galicia and Comunidad Valenciana. The presentation of the study shows the utility of this type of sampling when the population is accessible but there is a difficulty deriving from the lack of a sampling frame. However, the sample obtained is not a random representative one in statistical terms of the target population. It must be acknowledged that the final sample is representative of a 'pseudo-population' that approximates to the target population but is not identical to it.
The sampling design for the National Children¿s Study (NCS) calls for a population-based, multi-stage, clustered household sampling approach (visit our website for more information on the NCS : www.nationalchildrensstudy.gov). The full sample is designed to be representative of ...
NHEXAS PHASE I ARIZONA STUDY--METALS IN BLOOD ANALYTICAL RESULTS
The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 165 blood samples over 165 households. Each sample was collected as a venous sample from the primary respondent within each household during Stage III of the NHEXAS study. The samples...
Sepúlveda, Nuno; Drakeley, Chris
2015-04-03
In the last decade, several epidemiological studies have demonstrated the potential of using seroprevalence (SP) and seroconversion rate (SCR) as informative indicators of malaria burden in low transmission settings or in populations on the cusp of elimination. However, most of studies are designed to control ensuing statistical inference over parasite rates and not on these alternative malaria burden measures. SP is in essence a proportion and, thus, many methods exist for the respective sample size determination. In contrast, designing a study where SCR is the primary endpoint, is not an easy task because precision and statistical power are affected by the age distribution of a given population. Two sample size calculators for SCR estimation are proposed. The first one consists of transforming the confidence interval for SP into the corresponding one for SCR given a known seroreversion rate (SRR). The second calculator extends the previous one to the most common situation where SRR is unknown. In this situation, data simulation was used together with linear regression in order to study the expected relationship between sample size and precision. The performance of the first sample size calculator was studied in terms of the coverage of the confidence intervals for SCR. The results pointed out to eventual problems of under or over coverage for sample sizes ≤250 in very low and high malaria transmission settings (SCR ≤ 0.0036 and SCR ≥ 0.29, respectively). The correct coverage was obtained for the remaining transmission intensities with sample sizes ≥ 50. Sample size determination was then carried out for cross-sectional surveys using realistic SCRs from past sero-epidemiological studies and typical age distributions from African and non-African populations. For SCR < 0.058, African studies require a larger sample size than their non-African counterparts in order to obtain the same precision. The opposite happens for the remaining transmission intensities. With respect to the second sample size calculator, simulation unravelled the likelihood of not having enough information to estimate SRR in low transmission settings (SCR ≤ 0.0108). In that case, the respective estimates tend to underestimate the true SCR. This problem is minimized by sample sizes of no less than 500 individuals. The sample sizes determined by this second method highlighted the prior expectation that, when SRR is not known, sample sizes are increased in relation to the situation of a known SRR. In contrast to the first sample size calculation, African studies would now require lesser individuals than their counterparts conducted elsewhere, irrespective of the transmission intensity. Although the proposed sample size calculators can be instrumental to design future cross-sectional surveys, the choice of a particular sample size must be seen as a much broader exercise that involves weighting statistical precision with ethical issues, available human and economic resources, and possible time constraints. Moreover, if the sample size determination is carried out on varying transmission intensities, as done here, the respective sample sizes can also be used in studies comparing sites with different malaria transmission intensities. In conclusion, the proposed sample size calculators are a step towards the design of better sero-epidemiological studies. Their basic ideas show promise to be applied to the planning of alternative sampling schemes that may target or oversample specific age groups.
Chen, Henian; Zhang, Nanhua; Lu, Xiaosun; Chen, Sophie
2013-08-01
The method used to determine choice of standard deviation (SD) is inadequately reported in clinical trials. Underestimations of the population SD may result in underpowered clinical trials. This study demonstrates how using the wrong method to determine population SD can lead to inaccurate sample sizes and underpowered studies, and offers recommendations to maximize the likelihood of achieving adequate statistical power. We review the practice of reporting sample size and its effect on the power of trials published in major journals. Simulated clinical trials were used to compare the effects of different methods of determining SD on power and sample size calculations. Prior to 1996, sample size calculations were reported in just 1%-42% of clinical trials. This proportion increased from 38% to 54% after the initial Consolidated Standards of Reporting Trials (CONSORT) was published in 1996, and from 64% to 95% after the revised CONSORT was published in 2001. Nevertheless, underpowered clinical trials are still common. Our simulated data showed that all minimal and 25th-percentile SDs fell below 44 (the population SD), regardless of sample size (from 5 to 50). For sample sizes 5 and 50, the minimum sample SDs underestimated the population SD by 90.7% and 29.3%, respectively. If only one sample was available, there was less than 50% chance that the actual power equaled or exceeded the planned power of 80% for detecting a median effect size (Cohen's d = 0.5) when using the sample SD to calculate the sample size. The proportions of studies with actual power of at least 80% were about 95%, 90%, 85%, and 80% when we used the larger SD, 80% upper confidence limit (UCL) of SD, 70% UCL of SD, and 60% UCL of SD to calculate the sample size, respectively. When more than one sample was available, the weighted average SD resulted in about 50% of trials being underpowered; the proportion of trials with power of 80% increased from 90% to 100% when the 75th percentile and the maximum SD from 10 samples were used. Greater sample size is needed to achieve a higher proportion of studies having actual power of 80%. This study only addressed sample size calculation for continuous outcome variables. We recommend using the 60% UCL of SD, maximum SD, 80th-percentile SD, and 75th-percentile SD to calculate sample size when 1 or 2 samples, 3 samples, 4-5 samples, and more than 5 samples of data are available, respectively. Using the sample SD or average SD to calculate sample size should be avoided.
Besley, Aiken; Vijver, Martina G; Behrens, Paul; Bosker, Thijs
2017-01-15
Microplastics are ubiquitous in the environment, are frequently ingested by organisms, and may potentially cause harm. A range of studies have found significant levels of microplastics in beach sand. However, there is a considerable amount of methodological variability among these studies. Methodological variation currently limits comparisons as there is no standard procedure for sampling or extraction of microplastics. We identify key sampling and extraction procedures across the literature through a detailed review. We find that sampling depth, sampling location, number of repeat extractions, and settling times are the critical parameters of variation. Next, using a case-study we determine whether and to what extent these differences impact study outcomes. By investigating the common practices identified in the literature with the case-study, we provide a standard operating procedure for sampling and extracting microplastics from beach sand. Copyright © 2016 Elsevier Ltd. All rights reserved.
[Effect sizes, statistical power and sample sizes in "the Japanese Journal of Psychology"].
Suzukawa, Yumi; Toyoda, Hideki
2012-04-01
This study analyzed the statistical power of research studies published in the "Japanese Journal of Psychology" in 2008 and 2009. Sample effect sizes and sample statistical powers were calculated for each statistical test and analyzed with respect to the analytical methods and the fields of the studies. The results show that in the fields like perception, cognition or learning, the effect sizes were relatively large, although the sample sizes were small. At the same time, because of the small sample sizes, some meaningful effects could not be detected. In the other fields, because of the large sample sizes, meaningless effects could be detected. This implies that researchers who could not get large enough effect sizes would use larger samples to obtain significant results.
Study samples are too small to produce sufficiently precise reliability coefficients.
Charter, Richard A
2003-04-01
In a survey of journal articles, test manuals, and test critique books, the author found that a mean sample size (N) of 260 participants had been used for reliability studies on 742 tests. The distribution was skewed because the median sample size for the total sample was only 90. The median sample sizes for the internal consistency, retest, and interjudge reliabilities were 182, 64, and 36, respectively. The author presented sample size statistics for the various internal consistency methods and types of tests. In general, the author found that the sample sizes that were used in the internal consistency studies were too small to produce sufficiently precise reliability coefficients, which in turn could cause imprecise estimates of examinee true-score confidence intervals. The results also suggest that larger sample sizes have been used in the last decade compared with those that were used in earlier decades.
Towards robust and repeatable sampling methods in eDNA based studies.
Dickie, Ian A; Boyer, Stephane; Buckley, Hannah; Duncan, Richard P; Gardner, Paul; Hogg, Ian D; Holdaway, Robert J; Lear, Gavin; Makiola, Andreas; Morales, Sergio E; Powell, Jeff R; Weaver, Louise
2018-05-26
DNA based techniques are increasingly used for measuring the biodiversity (species presence, identity, abundance and community composition) of terrestrial and aquatic ecosystems. While there are numerous reviews of molecular methods and bioinformatic steps, there has been little consideration of the methods used to collect samples upon which these later steps are based. This represents a critical knowledge gap, as methodologically sound field sampling is the foundation for subsequent analyses. We reviewed field sampling methods used for metabarcoding studies of both terrestrial and freshwater ecosystem biodiversity over a nearly three-year period (n = 75). We found that 95% (n = 71) of these studies used subjective sampling methods, inappropriate field methods, and/or failed to provide critical methodological information. It would be possible for researchers to replicate only 5% of the metabarcoding studies in our sample, a poorer level of reproducibility than for ecological studies in general. Our findings suggest greater attention to field sampling methods and reporting is necessary in eDNA-based studies of biodiversity to ensure robust outcomes and future reproducibility. Methods must be fully and accurately reported, and protocols developed that minimise subjectivity. Standardisation of sampling protocols would be one way to help to improve reproducibility, and have additional benefits in allowing compilation and comparison of data from across studies. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
A measure of the signal-to-noise ratio of microarray samples and studies using gene correlations.
Venet, David; Detours, Vincent; Bersini, Hugues
2012-01-01
The quality of gene expression data can vary dramatically from platform to platform, study to study, and sample to sample. As reliable statistical analysis rests on reliable data, determining such quality is of the utmost importance. Quality measures to spot problematic samples exist, but they are platform-specific, and cannot be used to compare studies. As a proxy for quality, we propose a signal-to-noise ratio for microarray data, the "Signal-to-Noise Applied to Gene Expression Experiments", or SNAGEE. SNAGEE is based on the consistency of gene-gene correlations. We applied SNAGEE to a compendium of 80 large datasets on 37 platforms, for a total of 24,380 samples, and assessed the signal-to-noise ratio of studies and samples. This allowed us to discover serious issues with three studies. We show that signal-to-noise ratios of both studies and samples are linked to the statistical significance of the biological results. We showed that SNAGEE is an effective way to measure data quality for most types of gene expression studies, and that it often outperforms existing techniques. Furthermore, SNAGEE is platform-independent and does not require raw data files. The SNAGEE R package is available in BioConductor.
Mendez, Gregory O.; Foreman, William T.; Morita, Andrew; Majewski, Michael S.
2008-01-01
In 1998, the U.S. Geological Survey, in cooperation with the Sweetwater Authority, began a study to monitor water, air, and sediment at the Sweetwater and Loveland Reservoirs in San Diego County, California. The study includes regular sampling of water and air at Sweetwater Reservoir for chemical constituents, including volatile organic compounds (VOC), polynuclear aromatic hydrocarbons (PAH), pesticides, and major and trace elements. The purpose of this study is to monitor changes in contaminant composition and concentration during the construction and operation of State Route 125. To accomplish this, the study was divided into two phases. Phase One sampling (water years 1998–2004) determined baseline conditions for the detection frequency and the concentrations of target compounds in air and water. Phase Two sampling (starting water year 2005) continues at selected monitoring sites during and after construction of State Route 125 to assess the chemical impact this roadway alignment may have on water quality in the reservoir. Water samples were collected for VOCs and pesticides at Loveland Reservoir during Phase One and will be collected during Phase Two for comparison purposes. Air samples collected to monitor changes in VOCs, PAHs, and pesticides were analyzed by adapting methods used to analyze water samples. Bed-sediment samples have been and will be collected three times during the study; at the beginning of Phase One, at the start of Phase Two, and near the end of the study. In addition to the ongoing data collection, several special studies were initiated to assess the occurrence of specific chemicals of concern, such as trace metals, anthropogenic indicator compounds, and pharmaceuticals. This report describes the study design, and the sampling and analytical methods, and presents data from water and air samples collected during the fourth and fifth years of Phase One of the study (October 2001 to September 2003). Data collected during the first three years has been previously published. Three types of quality-control samples were used in this study: blanks, spikes, and replicates. Blanks and spikes are used to estimate result bias, and replicates are used to estimate result variability. Additionally, surrogate compounds were added at the laboratory to samples of VOCs, PAHs, pesticides, anthropogenic indicator compounds, and pharmaceuticals to monitor sample-specific performance of the analytical method.
Limited-sampling strategies for anti-infective agents: systematic review.
Sprague, Denise A; Ensom, Mary H H
2009-09-01
Area under the concentration-time curve (AUC) is a pharmacokinetic parameter that represents overall exposure to a drug. For selected anti-infective agents, pharmacokinetic-pharmacodynamic parameters, such as AUC/MIC (where MIC is the minimal inhibitory concentration), have been correlated with outcome in a few studies. A limited-sampling strategy may be used to estimate pharmacokinetic parameters such as AUC, without the frequent, costly, and inconvenient blood sampling that would be required to directly calculate the AUC. To discuss, by means of a systematic review, the strengths, limitations, and clinical implications of published studies involving a limited-sampling strategy for anti-infective agents and to propose improvements in methodology for future studies. The PubMed and EMBASE databases were searched using the terms "anti-infective agents", "limited sampling", "optimal sampling", "sparse sampling", "AUC monitoring", "abbreviated AUC", "abbreviated sampling", and "Bayesian". The reference lists of retrieved articles were searched manually. Included studies were classified according to modified criteria from the US Preventive Services Task Force. Twenty studies met the inclusion criteria. Six of the studies (involving didanosine, zidovudine, nevirapine, ciprofloxacin, efavirenz, and nelfinavir) were classified as providing level I evidence, 4 studies (involving vancomycin, didanosine, lamivudine, and lopinavir-ritonavir) provided level II-1 evidence, 2 studies (involving saquinavir and ceftazidime) provided level II-2 evidence, and 8 studies (involving ciprofloxacin, nelfinavir, vancomycin, ceftazidime, ganciclovir, pyrazinamide, meropenem, and alpha interferon) provided level III evidence. All of the studies providing level I evidence used prospectively collected data and proper validation procedures with separate, randomly selected index and validation groups. However, most of the included studies did not provide an adequate description of the methods or the characteristics of included patients, which limited their generalizability. Many limited-sampling strategies have been developed for anti-infective agents that do not have a clearly established link between AUC and clinical outcomes in humans. Future studies should first determine if there is an association between AUC monitoring and clinical outcomes. Thereafter, it may be worthwhile to prospectively develop and validate a limited-sampling strategy for the particular anti-infective agent in a similar population.
Khazaal, Yasser; van Singer, Mathias; Chatton, Anne; Achab, Sophia; Zullino, Daniele; Rothen, Stephane; Khan, Riaz; Billieux, Joel; Thorens, Gabriel
2014-07-07
The number of medical studies performed through online surveys has increased dramatically in recent years. Despite their numerous advantages (eg, sample size, facilitated access to individuals presenting stigmatizing issues), selection bias may exist in online surveys. However, evidence on the representativeness of self-selected samples in online studies is patchy. Our objective was to explore the representativeness of a self-selected sample of online gamers using online players' virtual characters (avatars). All avatars belonged to individuals playing World of Warcraft (WoW), currently the most widely used online game. Avatars' characteristics were defined using various games' scores, reported on the WoW's official website, and two self-selected samples from previous studies were compared with a randomly selected sample of avatars. We used scores linked to 1240 avatars (762 from the self-selected samples and 478 from the random sample). The two self-selected samples of avatars had higher scores on most of the assessed variables (except for guild membership and exploration). Furthermore, some guilds were overrepresented in the self-selected samples. Our results suggest that more proficient players or players more involved in the game may be more likely to participate in online surveys. Caution is needed in the interpretation of studies based on online surveys that used a self-selection recruitment procedure. Epidemiological evidence on the reduced representativeness of sample of online surveys is warranted.
Joyce, Alison P; Wang, Mengmeng; Lawrence-Henderson, Rosemary; Filliettaz, Cynthia; Leung, Sheldon S; Xu, Xin; O'Hara, Denise M
2014-07-01
The purpose of this study was to validate the approach of serial sampling from one mouse through ligand binding assay (LBA) quantification of dosed biotherapeutic in diluted whole blood to derive a pharmacokinetic (PK) profile. This investigation compared PK parameters obtained using serial and composite sampling methods following administration of human IgG monoclonal antibody. The serial sampling technique was established by collecting 10 μL of blood via tail vein at each time point following drug administration. Blood was immediately diluted into buffer followed by analyte quantitation using Gyrolab to derive plasma concentrations. Additional studies were conducted to understand matrix and sampling site effects on drug concentrations. The drug concentration profiles, irrespective of biological matrix, and PK parameters using both sampling methods were not significantly different. There were no sampling site effects on drug concentration measurements except that concentrations were slightly lower in sodium citrated plasma than other matrices. We recommend the application of mouse serial sampling, particularly with limiting drug supply or specialized animal models. Overall the efficiencies gained by serial sampling were 40-80% savings in study cost, animal usage, study length and drug conservation while inter-subject variability across PK parameters was less than 30%.
Sample size determination for mediation analysis of longitudinal data.
Pan, Haitao; Liu, Suyu; Miao, Danmin; Yuan, Ying
2018-03-27
Sample size planning for longitudinal data is crucial when designing mediation studies because sufficient statistical power is not only required in grant applications and peer-reviewed publications, but is essential to reliable research results. However, sample size determination is not straightforward for mediation analysis of longitudinal design. To facilitate planning the sample size for longitudinal mediation studies with a multilevel mediation model, this article provides the sample size required to achieve 80% power by simulations under various sizes of the mediation effect, within-subject correlations and numbers of repeated measures. The sample size calculation is based on three commonly used mediation tests: Sobel's method, distribution of product method and the bootstrap method. Among the three methods of testing the mediation effects, Sobel's method required the largest sample size to achieve 80% power. Bootstrapping and the distribution of the product method performed similarly and were more powerful than Sobel's method, as reflected by the relatively smaller sample sizes. For all three methods, the sample size required to achieve 80% power depended on the value of the ICC (i.e., within-subject correlation). A larger value of ICC typically required a larger sample size to achieve 80% power. Simulation results also illustrated the advantage of the longitudinal study design. The sample size tables for most encountered scenarios in practice have also been published for convenient use. Extensive simulations study showed that the distribution of the product method and bootstrapping method have superior performance to the Sobel's method, but the product method was recommended to use in practice in terms of less computation time load compared to the bootstrapping method. A R package has been developed for the product method of sample size determination in mediation longitudinal study design.
76 FR 56141 - Notice of Intent To Request New Information Collection
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-12
... level surveys of similar scope and size. The sample for each selected community will be strategically... of 2 hours per sample community. Full Study: The maximum sample size for the full study is 2,812... questionnaires. The initial sample size for this phase of the research is 100 respondents (10 respondents per...
ABSTRACT: Few studies have addressed the efficacy of composite sampling for measurement of indicator bacteria by QPCR. In this study, composite results were compared to single sample results for culture- and QPCR-based water quality monitoring. Composite results for both methods ...
Korfmacher, Walter; Luo, Yongyi; Ho, Stacy; Sun, Wei; Shen, Liduo; Wang, Jie; Wu, Zhongtao; Guo, Yang; Snow, Gregory; O'Shea, Thomas
2015-01-01
Serial sampling methods have been used for rat pharmacokinetic (PK) studies for over 20 years. Currently, it is still common to take 200-250 μL of blood at each timepoint when performing a PK study in rats and using serial sampling. While several techniques have been employed for collecting blood samples from rats, there is only limited published data to compare these methods. Recently, microsampling (≤ 50 μL) techniques have been reported as an alternative process for collecting blood samples from rats. In this report, five compounds were dosed orally into rats. For three proprietary compounds, jugular vein cannula (JVC) sampling was used to collect whole blood and plasma samples and capillary microsampling (CMS) was used to collect blood samples from the tail vein of the same animal. For the two other compounds, marketed drugs fluoxetine and glipizide, JVC sampling was used to collect both whole blood and blood CMS samples while tail-vein sampling from the same rats was also used to collect both whole blood and blood CMS samples. For the three proprietary compounds, the blood AUC as well as the blood concentration-time profile that were obtained from the tail vein were different from those obtained via JVC sampling. For fluoxetine, the blood total exposure (AUC) was not statistically different when comparing tail-vein sampling to JVC sampling, however the blood concentration-time profile that was obtained from the tail vein was different than the one obtained from JVC sampling. For glipizide, the blood AUC and concentration-time profile were not statistically different when comparing the tail-vein sampling to the JVC sampling. For both fluoxetine and glipizide, the blood concentration profiles obtained from CMS were equivalent to the blood concentration profiles obtained from the standard whole blood sampling, collected at the same sampling site. The data in this report provide strong evidence that blood CMS is a valuable small volume blood sampling approach for rats and that it provides results for test compound concentrations that are equivalent to those obtained from traditional whole blood sampling. The data also suggest that for some compounds, the concentration-time profile that is obtained for a test compound based on sampling from a rat tail vein may be different from that obtained from rat JVC sampling. In some cases, this shift in the concentration-time profile will result in different PK parameters for the test compound. Based on these observations, it is recommended that a consistent blood sampling method should be used for serial microsampling in discovery rat PK studies when testing multiple new chemical entities. If the rat tail vein sampling method is selected for PK screening, then conducting a bridging study on the lead compound is recommended to confirm that the rat PK obtained from JVC sampling is comparable to the tail-vein sampling. Copyright © 2015 Elsevier Inc. All rights reserved.
Arbes, Samuel J; Sever, Michelle; Vaughn, Ben; Mehta, Jigna; Lynch, Jeffrey T; Mitchell, Herman; Hoppin, Jane A; Spencer, Harvey L; Sandler, Dale P; Zeldin, Darryl C
2005-06-01
Studies of indoor allergen exposures are often limited by the cost and logistics of sending technicians to homes to collect dust. In this study we evaluated the feasibility of having subjects collect their own dust samples. The objectives were to compare allergen concentrations between subject- and technician-collected samples and to examine the sample return rate. Using a dust collection device and written instructions provided to them by mail, 102 subjects collected a combined dust sample from a bed and bedroom floor. Later the same day, a technician collected a side-by-side sample. Dust samples were weighed and analyzed for the cat allergen Fel d 1 and the dust mite allergen Der p 1. Fifty additional subjects who were enrolled by telephone were mailed dust collection packages and asked to return a dust sample and questionnaire by mail. A technician did not visit their homes. Correlations between subject- and technician-collected samples were strong for concentrations of Fel d 1 (r = 0.88) and Der p 1 (r = 0.87). With allergen concentrations dichotomized at lower limits of detection and clinically relevant thresholds, agreements between methodologies ranged from 91 to 98%. Although dust weights were correlated (r = 0.48, p < 0.001), subjects collected lighter samples. Among the group of 50 subjects, 46 returned a dust sample and completed questionnaire. The median number of days to receive a sample was 15. With some limitations, subject-collected dust sampling appears to be a valid and practical option for epidemiologic and clinical studies that report allergen concentration as a measure of exposure.
Arul, Pitchaikaran; Pushparaj, Magesh; Pandian, Kanmani; Chennimalai, Lingasamy; Rajendran, Karthika; Selvaraj, Eniya; Masilamani, Suresh
2018-01-01
An important component of laboratory medicine is preanalytical phase. Since laboratory report plays a major role in patient management, more importance should be given to the quality of laboratory tests. The present study was undertaken to find the prevalence and types of preanalytical errors at a tertiary care hospital in South India. In this cross-sectional study, a total of 118,732 samples ([62,474 outpatient department [OPD] and 56,258 inpatient department [IPD]) were received in hematology laboratory. These samples were analyzed for preanalytical errors such as misidentification, incorrect vials, inadequate samples, clotted samples, diluted samples, and hemolyzed samples. The overall prevalence of preanalytical errors found was 513 samples, which is 0.43% of the total number of samples received. The most common preanalytical error observed was inadequate samples followed by clotted samples. Overall frequencies (both OPD and IPD) of preanalytical errors such as misidentification, incorrect vials, inadequate samples, clotted samples, diluted samples, and hemolyzed samples were 0.02%, 0.05%, 0.2%, 0.12%, 0.02%, and 0.03%, respectively. The present study concluded that incorrect phlebotomy techniques due to lack of awareness is the main reason for preanalytical errors. This can be avoided by proper communication and coordination between laboratory and wards, proper training and continuing medical education programs for laboratory and paramedical staffs, and knowledge of the intervening factors that can influence laboratory results.
Kern, Margaret L; Hampson, Sarah E; Goldberg, Lewis R; Friedman, Howard S
2014-05-01
The present study used a collaborative framework to integrate 2 long-term prospective studies: the Terman Life Cycle Study and the Hawaii Personality and Health Longitudinal Study. Within a 5-factor personality-trait framework, teacher assessments of child personality were rationally and empirically aligned to establish similar factor structures across samples. Comparable items related to adult self-rated health, education, and alcohol use were harmonized, and data were pooled on harmonized items. A structural model was estimated as a multigroup analysis. Harmonized child personality factors were then used to examine markers of physiological dysfunction in the Hawaii sample and mortality risk in the Terman sample. Harmonized conscientiousness predicted less physiological dysfunction in the Hawaii sample and lower mortality risk in the Terman sample. These results illustrate how collaborative, integrative work with multiple samples offers the exciting possibility that samples from different cohorts and ages can be linked together to directly test life span theories of personality and health. (PsycINFO Database Record (c) 2014 APA, all rights reserved).
Suhonen, Riitta; Stolt, Minna; Katajisto, Jouko; Leino-Kilpi, Helena
2015-12-01
To report a review of quality regarding sampling, sample and data collection procedures of empirical nursing research of ethical climate studies where nurses were informants. Surveys are needed to obtain generalisable information about topics sensitive to nursing. Methodological quality of the studies is of key concern, especially the description of sampling and data collection procedures. Methodological literature review. Using the electronic MEDLINE database, empirical nursing research articles focusing on ethical climate were accessed in 2013 (earliest-22 November 2013). Using the search terms 'ethical' AND ('climate*' OR 'environment*') AND ('nurse*' OR 'nursing'), 376 citations were retrieved. Based on a four-phase retrieval process, 26 studies were included in the detailed analysis. Sampling method was reported in 58% of the studies, and it was random in a minority of the studies (26%). The identification of target sample and its size (92%) was reported, whereas justification for sample size was less often given. In over two-thirds (69%) of the studies with identifiable response rate, it was below 75%. A variety of data collection procedures were used with large amount of missing data about the details of who distributed, recruited and collected the questionnaires. Methods to increase response rates were seldom described. Discussion about nonresponse, representativeness of the sample and generalisability of the results was missing in many studies. This review highlights the methodological challenges and developments that need to be considered in ensuring the use of valid information in developing health care through research findings. © 2015 Nordic College of Caring Science.
Application of allflex conservation buffer in illumina genotyping.
de Groot, M; Ras, T; van Haeringen, W A
2016-12-01
This experiment was designed to study if liquid conservation buffer used in the novel Tissue Sampling Technology (TST) from Allflex can be used for Illumina BeadChip genotyping. Ear punches were collected from 6 bovine samples, using both the Tissue Sampling Unit (TSU) as well as the Total Tagger Universal (TTU) collection system. The stability of the liquid conservation buffer was tested by genotyping samples on Illumina BeadChips, incubated at 0, 3, 15, 24, 48, 72, 168, 336, 720 h after sample collection. Additionally, a replenishment study was designed to test how often the liquid conservation buffer could be completely replenished before a significant call rate drop could be observed. Results from the stability study showed an average call rate of 0.993 for samples collected with the TSU system and 0.953 for samples collected with the TTU system, both exceeding the inclusion threshold call rate of 0.85. As an additional control, the identity of the individual animals was confirmed using the International Society of Animal Genetics (ISAG) recommended SNP panel. The replenishment study revealed a slight drop in the sample call rate after replenishing the conservation buffer for the fourth time for the TSU as well as the TTU samples. In routine analysis, this application allows for multiple experiments to be performed on the liquid conservation buffer, while maintaining the tissue samples for future use. The data collected in this study shows that the liquid conservation buffer used in the TST system can be used for Illumina BeadChip genotyping applications.
Kraschnewski, Jennifer L; Keyserling, Thomas C; Bangdiwala, Shrikant I; Gizlice, Ziya; Garcia, Beverly A; Johnston, Larry F; Gustafson, Alison; Petrovic, Lindsay; Glasgow, Russell E; Samuel-Hodge, Carmen D
2010-01-01
Studies of type 2 translation, the adaption of evidence-based interventions to real-world settings, should include representative study sites and staff to improve external validity. Sites for such studies are, however, often selected by convenience sampling, which limits generalizability. We used an optimized probability sampling protocol to select an unbiased, representative sample of study sites to prepare for a randomized trial of a weight loss intervention. We invited North Carolina health departments within 200 miles of the research center to participate (N = 81). Of the 43 health departments that were eligible, 30 were interested in participating. To select a representative and feasible sample of 6 health departments that met inclusion criteria, we generated all combinations of 6 from the 30 health departments that were eligible and interested. From the subset of combinations that met inclusion criteria, we selected 1 at random. Of 593,775 possible combinations of 6 counties, 15,177 (3%) met inclusion criteria. Sites in the selected subset were similar to all eligible sites in terms of health department characteristics and county demographics. Optimized probability sampling improved generalizability by ensuring an unbiased and representative sample of study sites.
Sample size of the reference sample in a case-augmented study.
Ghosh, Palash; Dewanji, Anup
2017-05-01
The case-augmented study, in which a case sample is augmented with a reference (random) sample from the source population with only covariates information known, is becoming popular in different areas of applied science such as pharmacovigilance, ecology, and econometrics. In general, the case sample is available from some source (for example, hospital database, case registry, etc.); however, the reference sample is required to be drawn from the corresponding source population. The required minimum size of the reference sample is an important issue in this regard. In this work, we address the minimum sample size calculation and discuss related issues. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steger, J.L.; Bursey, J.T.; Merrill, R.G.
1999-03-01
This report presents the results of laboratory studies to develop and evaluate a method for the sampling and analysis of phosgene from stationary sources of air emissions using diethylamine (DEA) in toluene as the collection media. The method extracts stack gas from emission sources and stabilizes the reactive gas for subsequent analysis. DEA was evaluated both in a benchtop study and in a laboratory train spiking study. This report includes results for both the benchtop study and the train spiking study. Benchtop studies to evaluate the suitability of DEA for collecting and analyzing phosgene investigated five variables: storage time, DEAmore » concentration, moisture/pH, phosgene concentration, and sample storage temperature. Prototype sampling train studies were performed to determine if the benchtop chemical studies were transferable to a Modified Method 5 sampling train collecting phosgene in the presence of clean air mixed with typical stack gas components. Four conditions, which varied the moisture and phosgene spike were evaluated in triplicate. In addition to research results, the report includes a detailed draft method for sampling and analysis of phosgene from stationary source emissions.« less
GY SAMPLING THEORY IN ENVIRONMENTAL STUDIES 1: ASSESSING SOIL SPLITTING PROTOCOLS
Five soil sample splitting methods (riffle splitting, paper cone riffle splitting, fractional shoveling, coning and quartering, and grab sampling) were evaluated with synthetic samples to verify Pierre Gy sampling theory expectations. Individually prepared samples consisting of l...
Oral sampling methods are associated with differences in immune marker concentrations.
Fakhry, Carole; Qeadan, Fares; Gilman, Robert H; Yori, Pablo; Kosek, Margaret; Patterson, Nicole; Eisele, David W; Gourin, Christine G; Chitguppi, Chandala; Marks, Morgan; Gravitt, Patti
2018-06-01
To determine whether the concentration and distribution of immune markers in paired oral samples were similar. Clinical research. Cross-sectional study. Paired saliva and oral secretions (OS) samples were collected. The concentration of immune markers was estimated using Luminex multiplex assay (Thermo Fisher Scientific, Waltham, MA). For each sample, the concentration of respective immune markers was normalized to total protein present and log-transformed. Median concentrations of immune markers were compared between both types of samples. Intermarker correlation in each sampling method and across sampling methods was evaluated. There were 90 study participants. Concentrations of immune markers in saliva samples were significantly different from concentrations in OS samples. Oral secretions samples showed higher concentrations of immunoregulatory markers, whereas the saliva samples contained proinflammatory markers in higher concentration. The immune marker profile in saliva samples is distinct from the immune marker profile in paired OS samples. 2b. Laryngoscope, 128:E214-E221, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Hille, Katja; Möbius, Nadine; Akmatov, Manas K; Verspohl, Jutta; Rabold, Denise; Hartmann, Maria; Günther, Kathrin; Obi, Nadia; Kreienbrock, Lothar
2014-11-01
Cats and dogs live in more than 20 % of German households and the contact between these pets and their owners can be very close. Therefore, a transmission of zoonotic pathogens may occur. To investigate whether zoonotic research questions can be examined in the context of population-based studies like the German National Cohort (GNC), two studies on different study populations were conducted as part of the feasibility tests of the GNC. The aim of the first study was to quantify the actual exposure of participants of the GNC to cats and dogs. In the second study summarised here the feasibility of the sampling of cats and dogs by their owners was tested. To quantify the exposure of participants of the GNC to cats and dogs 744 study participants of the Pretests of the GNC were asked whether they had contact with animals. Currently 10 % have a dog and 14 % have a cat in their household. These figures confirm that a large proportion of the German population has contact with pets and that there is a need for further zoonoses research. To establish the collection of biological samples from cats and dogs in the context of large-scale population-based studies feasible methods are needed. Therefore, a study was conducted to test whether pet owners can take samples from their cats and dogs and whether the quality of these samples is comparable to samples taken by a qualified veterinarian. A total of 82 dog and 18 cat owners were recruited in two veterinary practices in Hannover and the Clinic for Small Animals at the University of Veterinary Medicine in Hannover. Sampling instructions and sample material for nasal and buccal swabs, faecal samples and, in the case of cat owners, a brush for fur samples, were given to the pet owners. The pet owners were asked to take the samples from their pets at home and to send the samples by surface mail. Swab samples were cultured and bacterial growth was quantified independent of bacterial species. The growth of Gram-positive and Gram-negative bacteria from samples taken by the veterinarian and the pet owners were compared. For Gram-positive bacteria the agreement of laboratory results was 71 % for nasal swabs and 78 % for oral swabs while for Gram-negative bacteria the agreement of laboratory results was 55 % for nasal swabs and 87 % for oral swabs. In conclusion it has been shown that participants of the GNC are exposed to cats and dogs and that the sampling of cats and dogs by their owners is a feasible method which can be a useful tool for zoonoses research in population-based studies.
Environmental sampling can be difficult and expensive to carry out. Those taking the samples would like to integrate their knowledge of the system of study or their judgment about the system into the sample selection process to decrease the number of necessary samples. However,...
Sample environment for in situ synchrotron corrosion studies of materials in extreme environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elbakhshwan, Mohamed S.; Gill, Simerjeet K.; Motta, Arthur T.
A new in situ sample environment has been designed and developed to study the interfacial interactions of nuclear cladding alloys with high temperature steam. The sample environment is particularly optimized for synchrotron X-ray diffraction (XRD) studies for in situ structural analysis. The sample environment is highly corrosion resistant and can be readily adapted for steam environments. The in situ sample environment design complies with G2 ASTM standards for studying corrosion in zirconium and its alloys and offers remote temperature and pressure monitoring during the in situ data collection. The use of the in situ sample environment is exemplified by monitoringmore » the oxidation of metallic zirconium during exposure to steam at 350°C. Finally, the in situ sample environment provides a powerful tool for fundamental understanding of corrosion mechanisms by elucidating the substoichiometric oxide phases formed during early stages of corrosion, which can provide a better understanding the oxidation process.« less
Sample environment for in situ synchrotron corrosion studies of materials in extreme environments
Elbakhshwan, Mohamed S.; Gill, Simerjeet K.; Motta, Arthur T.; ...
2016-10-25
A new in situ sample environment has been designed and developed to study the interfacial interactions of nuclear cladding alloys with high temperature steam. The sample environment is particularly optimized for synchrotron X-ray diffraction (XRD) studies for in situ structural analysis. The sample environment is highly corrosion resistant and can be readily adapted for steam environments. The in situ sample environment design complies with G2 ASTM standards for studying corrosion in zirconium and its alloys and offers remote temperature and pressure monitoring during the in situ data collection. The use of the in situ sample environment is exemplified by monitoringmore » the oxidation of metallic zirconium during exposure to steam at 350°C. Finally, the in situ sample environment provides a powerful tool for fundamental understanding of corrosion mechanisms by elucidating the substoichiometric oxide phases formed during early stages of corrosion, which can provide a better understanding the oxidation process.« less
(PRESENTED NAQC SAN FRANCISCO, CA) COARSE PM METHODS STUDY: STUDY DESIGN AND RESULTS
Comprehensive field studies were conducted to evaluate the performance of sampling methods for measuring the coarse fraction of PM10 in ambient air. Five separate sampling approaches were evaluated at each of three sampling sites. As the primary basis of comparison, a discrete ...
Diversity of Leptospira spp. in Rats and Environment from Urban Areas of Sarawak, Malaysia
Pui, Chai Fung; Apun, Kasing; Su'ut, Lela
2017-01-01
Various prevalence studies on Leptospira in animals and humans, as well as environmental samples, had been conducted worldwide, including Malaysia. However, limited studies have been documented on the presence of pathogenic, intermediate, and saprophytic Leptospira in selected animals and environments. This study was therefore conducted to detect Leptospira spp. in rats, soil, and water from urban areas of Sarawak using the polymerase chain reaction (PCR) method. A total of 107 rats, 292 soil samples, and 324 water samples were collected from April 2014 to February 2015. Pathogenic Leptospira was present in 5.6% (6/107) of rats, 11.6% (34/292) of soil samples, and 1.9% (6/324) of water samples. Intermediate Leptospira was present in 2.7% (8/292) of soil samples and 1.9% (6/324) of water samples. Saprophytic Leptospira was present in 10.3% (11/107) of rats, 1.4% (4/292) of soil samples, and 0.3% (1/324) of water samples. From this study, 76 Leptospira spp. were isolated. Based on DNA sequencing, the dominant Leptospira spp. circulating in urban areas of Sarawak are pathogenic Leptospira noguchii, intermediate Leptospira wolffii serovar Khorat, and saprophytic Leptospira meyeri, respectively. Overall, this study provided important surveillance data on the prevalence of Leptospira spp. from rats and the environment, with dominant local serovars in urban areas of Sarawak. PMID:28348601
Diversity of Leptospira spp. in Rats and Environment from Urban Areas of Sarawak, Malaysia.
Pui, Chai Fung; Bilung, Lesley Maurice; Apun, Kasing; Su'ut, Lela
2017-01-01
Various prevalence studies on Leptospira in animals and humans, as well as environmental samples, had been conducted worldwide, including Malaysia. However, limited studies have been documented on the presence of pathogenic, intermediate, and saprophytic Leptospira in selected animals and environments. This study was therefore conducted to detect Leptospira spp. in rats, soil, and water from urban areas of Sarawak using the polymerase chain reaction (PCR) method. A total of 107 rats, 292 soil samples, and 324 water samples were collected from April 2014 to February 2015. Pathogenic Leptospira was present in 5.6% (6/107) of rats, 11.6% (34/292) of soil samples, and 1.9% (6/324) of water samples. Intermediate Leptospira was present in 2.7% (8/292) of soil samples and 1.9% (6/324) of water samples. Saprophytic Leptospira was present in 10.3% (11/107) of rats, 1.4% (4/292) of soil samples, and 0.3% (1/324) of water samples. From this study, 76 Leptospira spp. were isolated. Based on DNA sequencing, the dominant Leptospira spp. circulating in urban areas of Sarawak are pathogenic Leptospira noguchii , intermediate Leptospira wolffii serovar Khorat, and saprophytic Leptospira meyeri , respectively. Overall, this study provided important surveillance data on the prevalence of Leptospira spp. from rats and the environment, with dominant local serovars in urban areas of Sarawak.
Strandberg, Gunnar; Lipcsey, Miklós; Eriksson, Mats; Larsson, Anders
2014-01-01
Intraosseous (IO) access is a valuable tool in prehospital locations and in emergency departments when other forms of vascular access are unavailable. Creatinine is often used for dose adjustment of drugs that may be administered through intraosseous cannulae. We aimed to study the possibility of analysing creatinine in intraosseous samples and study the accuracy and precision of such measurements. Eight pigs with endotoxin induced septic shock were sampled hourly for six hours and analysed for plasma creatinine. Samples were collected from arterial, venous, and IO cannulae. There was an increase in creatinine values during the later part of the experiment. The coefficients of variation between the three sampling sites were less than 10% at all sampling times. Based on our findings intraosseous samples can be used for creatinine determination in emergency settings.
Ort, Christoph; Lawrence, Michael G; Rieckermann, Jörg; Joss, Adriano
2010-08-15
The analysis of 87 peer-reviewed journal articles reveals that sampling for pharmaceuticals and personal care products (PPCPs) and illicit drugs in sewers and sewage treatment plant influents is mostly carried out according to existing tradition or standard laboratory protocols. Less than 5% of all studies explicitly consider internationally acknowledged guidelines or methods for the experimental design of monitoring campaigns. In the absence of a proper analysis of the system under investigation, the importance of short-term pollutant variations was typically not addressed. Therefore, due to relatively long sampling intervals, potentially inadequate sampling modes, or insufficient documentation, it remains unclear for the majority of reviewed studies whether observed variations can be attributed to "real" variations or if they simply reflect sampling artifacts. Based on results from previous and current work, the present paper demonstrates that sampling errors can lead to overinterpretation of measured data and ultimately, wrong conclusions. Depending on catchment size, sewer type, sampling setup, substance of interest, and accuracy of analytical method, avoidable sampling artifacts can range from "not significant" to "100% or more" for different compounds even within the same study. However, in most situations sampling errors can be reduced greatly, and sampling biases can be eliminated completely, by choosing an appropriate sampling mode and frequency. This is crucial, because proper sampling will help to maximize the value of measured data for the experimental assessment of the fate of PPCPs as well as for the formulation and validation of mathematical models. The trend from reporting presence or absence of a compound in "clean" water samples toward the quantification of PPCPs in raw wastewater requires not only sophisticated analytical methods but also adapted sampling methods. With increasing accuracy of chemical analyses, inappropriate sampling increasingly represents the major source of inaccuracy. A condensed step-by-step Sampling Guide is proposed as a starting point for future studies.
Enhancing sampling design in mist-net bat surveys by accounting for sample size optimization.
Trevelin, Leonardo Carreira; Novaes, Roberto Leonan Morim; Colas-Rosas, Paul François; Benathar, Thayse Cristhina Melo; Peres, Carlos A
2017-01-01
The advantages of mist-netting, the main technique used in Neotropical bat community studies to date, include logistical implementation, standardization and sampling representativeness. Nonetheless, study designs still have to deal with issues of detectability related to how different species behave and use the environment. Yet there is considerable sampling heterogeneity across available studies in the literature. Here, we approach the problem of sample size optimization. We evaluated the common sense hypothesis that the first six hours comprise the period of peak night activity for several species, thereby resulting in a representative sample for the whole night. To this end, we combined re-sampling techniques, species accumulation curves, threshold analysis, and community concordance of species compositional data, and applied them to datasets of three different Neotropical biomes (Amazonia, Atlantic Forest and Cerrado). We show that the strategy of restricting sampling to only six hours of the night frequently results in incomplete sampling representation of the entire bat community investigated. From a quantitative standpoint, results corroborated the existence of a major Sample Area effect in all datasets, although for the Amazonia dataset the six-hour strategy was significantly less species-rich after extrapolation, and for the Cerrado dataset it was more efficient. From the qualitative standpoint, however, results demonstrated that, for all three datasets, the identity of species that are effectively sampled will be inherently impacted by choices of sub-sampling schedule. We also propose an alternative six-hour sampling strategy (at the beginning and the end of a sample night) which performed better when resampling Amazonian and Atlantic Forest datasets on bat assemblages. Given the observed magnitude of our results, we propose that sample representativeness has to be carefully weighed against study objectives, and recommend that the trade-off between logistical constraints and additional sampling performance should be carefully evaluated.
Enhancing sampling design in mist-net bat surveys by accounting for sample size optimization
Trevelin, Leonardo Carreira; Novaes, Roberto Leonan Morim; Colas-Rosas, Paul François; Benathar, Thayse Cristhina Melo; Peres, Carlos A.
2017-01-01
The advantages of mist-netting, the main technique used in Neotropical bat community studies to date, include logistical implementation, standardization and sampling representativeness. Nonetheless, study designs still have to deal with issues of detectability related to how different species behave and use the environment. Yet there is considerable sampling heterogeneity across available studies in the literature. Here, we approach the problem of sample size optimization. We evaluated the common sense hypothesis that the first six hours comprise the period of peak night activity for several species, thereby resulting in a representative sample for the whole night. To this end, we combined re-sampling techniques, species accumulation curves, threshold analysis, and community concordance of species compositional data, and applied them to datasets of three different Neotropical biomes (Amazonia, Atlantic Forest and Cerrado). We show that the strategy of restricting sampling to only six hours of the night frequently results in incomplete sampling representation of the entire bat community investigated. From a quantitative standpoint, results corroborated the existence of a major Sample Area effect in all datasets, although for the Amazonia dataset the six-hour strategy was significantly less species-rich after extrapolation, and for the Cerrado dataset it was more efficient. From the qualitative standpoint, however, results demonstrated that, for all three datasets, the identity of species that are effectively sampled will be inherently impacted by choices of sub-sampling schedule. We also propose an alternative six-hour sampling strategy (at the beginning and the end of a sample night) which performed better when resampling Amazonian and Atlantic Forest datasets on bat assemblages. Given the observed magnitude of our results, we propose that sample representativeness has to be carefully weighed against study objectives, and recommend that the trade-off between logistical constraints and additional sampling performance should be carefully evaluated. PMID:28334046
Mortamais, Marion; Chevrier, Cécile; Philippat, Claire; Petit, Claire; Calafat, Antonia M; Ye, Xiaoyun; Silva, Manori J; Brambilla, Christian; Eijkemans, Marinus J C; Charles, Marie-Aline; Cordier, Sylvaine; Slama, Rémy
2012-04-26
Environmental epidemiology and biomonitoring studies typically rely on biological samples to assay the concentration of non-persistent exposure biomarkers. Between-participant variations in sampling conditions of these biological samples constitute a potential source of exposure misclassification. Few studies attempted to correct biomarker levels for this error. We aimed to assess the influence of sampling conditions on concentrations of urinary biomarkers of select phenols and phthalates, two widely-produced families of chemicals, and to standardize biomarker concentrations on sampling conditions. Urine samples were collected between 2002 and 2006 among 287 pregnant women from Eden and Pélagie cohorts, from which phthalates and phenols metabolites levels were assayed. We applied a 2-step standardization method based on regression residuals. First, the influence of sampling conditions (including sampling hour, duration of storage before freezing) and of creatinine levels on biomarker concentrations were characterized using adjusted linear regression models. In the second step, the model estimates were used to remove the variability in biomarker concentrations due to sampling conditions and to standardize concentrations as if all samples had been collected under the same conditions (e.g., same hour of urine collection). Sampling hour was associated with concentrations of several exposure biomarkers. After standardization for sampling conditions, median concentrations differed by--38% for 2,5-dichlorophenol to +80 % for a metabolite of diisodecyl phthalate. However, at the individual level, standardized biomarker levels were strongly correlated (correlation coefficients above 0.80) with unstandardized measures. Sampling conditions, such as sampling hour, should be systematically collected in biomarker-based studies, in particular when the biomarker half-life is short. The 2-step standardization method based on regression residuals that we proposed in order to limit the impact of heterogeneity in sampling conditions could be further tested in studies describing levels of biomarkers or their influence on health.
Zhu, Hong; Xu, Xiaohan; Ahn, Chul
2017-01-01
Paired experimental design is widely used in clinical and health behavioral studies, where each study unit contributes a pair of observations. Investigators often encounter incomplete observations of paired outcomes in the data collected. Some study units contribute complete pairs of observations, while the others contribute either pre- or post-intervention observations. Statistical inference for paired experimental design with incomplete observations of continuous outcomes has been extensively studied in literature. However, sample size method for such study design is sparsely available. We derive a closed-form sample size formula based on the generalized estimating equation approach by treating the incomplete observations as missing data in a linear model. The proposed method properly accounts for the impact of mixed structure of observed data: a combination of paired and unpaired outcomes. The sample size formula is flexible to accommodate different missing patterns, magnitude of missingness, and correlation parameter values. We demonstrate that under complete observations, the proposed generalized estimating equation sample size estimate is the same as that based on the paired t-test. In the presence of missing data, the proposed method would lead to a more accurate sample size estimate comparing with the crude adjustment. Simulation studies are conducted to evaluate the finite-sample performance of the generalized estimating equation sample size formula. A real application example is presented for illustration.
Sampling estimators of total mill receipts for use in timber product output studies
John P. Brown; Richard G. Oderwald
2012-01-01
Data from the 2001 timber product output study for Georgia was explored to determine new methods for stratifying mills and finding suitable sampling estimators. Estimators for roundwood receipts totals comprised several types: simple random sample, ratio, stratified sample, and combined ratio. Two stratification methods were examined: the Dalenius-Hodges (DH) square...
Sampling bias in blending validation and a different approach to homogeneity assessment.
Kraemer, J; Svensson, J R; Melgaard, H
1999-02-01
Sampling of batches studied for validation is reported. A thief particularly suited for granules, rather than cohesive powders, was used in the study. It is shown, as has been demonstrated in the past, that traditional 1x to 3x thief sampling of a blend is biased, and that the bias decreases as the sample size increases. It is shown that taking 50 samples of tablets after blending and testing this subpopulation for normality is a discriminating manner of testing for homogeneity. As a criterion, it is better than sampling at mixer or drum stage would be even if an unbiased sampling device were available.
Assessment of sampling stability in ecological applications of discriminant analysis
Williams, B.K.; Titus, K.
1988-01-01
A simulation study was undertaken to assess the sampling stability of the variable loadings in linear discriminant function analysis. A factorial design was used for the factors of multivariate dimensionality, dispersion structure, configuration of group means, and sample size. A total of 32,400 discriminant analyses were conducted, based on data from simulated populations with appropriate underlying statistical distributions. A review of 60 published studies and 142 individual analyses indicated that sample sizes in ecological studies often have met that requirement. However, individual group sample sizes frequently were very unequal, and checks of assumptions usually were not reported. The authors recommend that ecologists obtain group sample sizes that are at least three times as large as the number of variables measured.
Samples in applied psychology: over a decade of research in review.
Shen, Winny; Kiger, Thomas B; Davies, Stacy E; Rasch, Rena L; Simon, Kara M; Ones, Deniz S
2011-09-01
This study examines sample characteristics of articles published in Journal of Applied Psychology (JAP) from 1995 to 2008. At the individual level, the overall median sample size over the period examined was approximately 173, which is generally adequate for detecting the average magnitude of effects of primary interest to researchers who publish in JAP. Samples using higher units of analyses (e.g., teams, departments/work units, and organizations) had lower median sample sizes (Mdn ≈ 65), yet were arguably robust given typical multilevel design choices of JAP authors despite the practical constraints of collecting data at higher units of analysis. A substantial proportion of studies used student samples (~40%); surprisingly, median sample sizes for student samples were smaller than working adult samples. Samples were more commonly occupationally homogeneous (~70%) than occupationally heterogeneous. U.S. and English-speaking participants made up the vast majority of samples, whereas Middle Eastern, African, and Latin American samples were largely unrepresented. On the basis of study results, recommendations are provided for authors, editors, and readers, which converge on 3 themes: (a) appropriateness and match between sample characteristics and research questions, (b) careful consideration of statistical power, and (c) the increased popularity of quantitative synthesis. Implications are discussed in terms of theory building, generalizability of research findings, and statistical power to detect effects. PsycINFO Database Record (c) 2011 APA, all rights reserved
THE NEW YORK CITY URBAN DISPERSION PROGRAM MARCH 2005 FIELD STUDY: TRACER METHODS AND RESULTS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
WATSON, T.B.; HEISER, J.; KALB, P.
The Urban Dispersion Program March 2005 Field Study tracer releases, sampling, and analytical methods are described in detail. There were two days where tracer releases and sampling were conducted. A total of 16.0 g of six tracers were released during the first test day or Intensive Observation Period (IOP) 1 and 15.7 g during IOP 2. Three types of sampling instruments were used in this study. Sequential air samplers, or SAS, collected six-minute samples, while Brookhaven atmospheric tracer samplers (BATS) and personal air samplers (PAS) collected thirty-minute samples. There were a total of 1300 samples resulting from the two IOPs.more » Confidence limits in the sampling and analysis method were 20% as determined from 100 duplicate samples. The sample recovery rate was 84%. The integrally averaged 6-minute samples were compared to the 30-minute samples. The agreement was found to be good in most cases. The validity of using a background tracer to calculate sample volumes was examined and also found to have a confidence level of 20%. Methods for improving sampling and analysis are discussed. The data described in this report are available as Excel files. An additional Excel file of quality assured tracer data for use in model validation efforts is also available. The file consists of extensively quality assured BATS tracer data with background concentrations subtracted.« less
ERIC Educational Resources Information Center
Yavuzer, Yasemin
2015-01-01
The purpose of this study is to examine the relationship between cognitive distortions, self-handicapping tendencies, and self-esteem in a sample of students studying in a school of education. The sample of the study was comprised of 507 volunteer students chosen through random sampling from a total of 4,720 students who were studying teaching at…
McCleskey, R. Blaine; Nordstrom, D. Kirk; Steiger, Judy I.; Kimball, Briant A.; Verplanck, Philip L.
2003-01-01
Water analyses are reported for 259 samples collected from the Red River, New Mexico, and its tributaries during low-flow(2001) and spring snowmelt (2002) tracer studies. Water samples were collected along a 20-kilometer reach of the Red River beginning just east of the town of Red River and ending at the U.S. Geological Survey streamflow-gaging station located east of Questa, New Mexico. The study area was divided into three sections where separate injections and synoptic sampling events were performed during the low-flow tracer study. During the spring snowmelt tracer study, three tracer injections and synoptic sampling events were performed bracketing the areas with the greatest metal loading into the Red River as determined from the low-flow tracer study. The lowflow tracer synoptic sampling events were August 17, 20, and 24, 2001. The synoptic sampling events for the spring snowmelt tracer were March 30, 31, and April 1, 2002. Stream and large inflow water samples were sampled using equal-width and depth-integrated sampling methods and composited into half-gallon bottles. Grab water samples were collected from smaller inflows. Stream temperatures were measured at the time of sample collection. Samples were transported to a nearby central processing location where pH and specific conductance were measured and the samples processed for chemical analyses. Cations, trace metals, iron redox species, and fluoride were analyzed at the U.S. Geological Survey laboratory in Boulder, Colorado. Cations and trace metal concentrations were determined using inductively coupled plasma-optical emission spectrometry and graphite furnace atomic absorption spectrometry. Arsenic concentrations were determined using hydride generation atomic absorption spectrometry, iron redox species were measured using ultraviolet-visible spectrometry, and fluoride concentrations were determined using an ion-selective electrode. Alkalinity was measured by automated titration, and sulfate, chloride, and bromide were analyzed by ion chromatography at the U.S. Geological Survey laboratory in Salt Lake City, Utah.
Nayak, Ranganath N; Dixitraj, P T; Nayak, Aarati; Bhat, Kishore
2015-09-01
This study aimed at evaluating the anti-microbial activity of spore powder of Ganoderma lucidum on Prevotella intermedia isolated from subgingival plaque from chronic periodontitis patients. Written informed consent was obtained from each subject enrolled in the study. The Institutional Ethics Committee granted the ethical clearance for the study. This study included 20 patients diagnosed with chronic periodontitis. Pooled subgingival plaque samples were collected using sterile curettes from the deepest sites of periodontal pockets. The collected samples were then transported in 1 mL of reduced transport fluid. The organisms were cultured and confirmed. These organisms were then used for minimum inhibitory concentration (MIC) procedure. Mean of the MIC value obtained was calculated. Thirteen out of the 20 clinical samples were tested that showed sensitivity at various concentrations. Five samples showed sensitivity at all concentrations. Twelve samples showed sensitivity at 8 mcg/ml. Eleven samples showed sensitivity at 4 mcg/ml, 8 samples showed sensitivity at 2 mcg/ml, and 5 samples showed sensitivity even at 1 mcg/ml. Mean MIC value of G. lucidum spore powder for P. intermedia obtained was 3.62 mcg/ml. G. lucidum with its multipotential bioactivity could be used as an anti-microbial, in conjunction with conventional therapy in periodontal disease.
Yin, Ge; Danielsson, Sara; Dahlberg, Anna-Karin; Zhou, Yihui; Qiu, Yanling; Nyberg, Elisabeth; Bignert, Anders
2017-10-01
Environmental monitoring typically assumes samples and sampling activities to be representative of the population being studied. Given a limited budget, an appropriate sampling strategy is essential to support detecting temporal trends of contaminants. In the present study, based on real chemical analysis data on polybrominated diphenyl ethers in snails collected from five subsites in Tianmu Lake, computer simulation is performed to evaluate three sampling strategies by the estimation of required sample size, to reach a detection of an annual change of 5% with a statistical power of 80% and 90% with a significant level of 5%. The results showed that sampling from an arbitrarily selected sampling spot is the worst strategy, requiring much more individual analyses to achieve the above mentioned criteria compared with the other two approaches. A fixed sampling site requires the lowest sample size but may not be representative for the intended study object e.g. a lake and is also sensitive to changes of that particular sampling site. In contrast, sampling at multiple sites along the shore each year, and using pooled samples when the cost to collect and prepare individual specimens are much lower than the cost for chemical analysis, would be the most robust and cost efficient strategy in the long run. Using statistical power as criterion, the results demonstrated quantitatively the consequences of various sampling strategies, and could guide users with respect of required sample sizes depending on sampling design for long term monitoring programs. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Hartati; Aryanti, S.; Muherman, S. Y.
2017-03-01
The main purpose study was to find out the effect of once a year of 400 mg albendazole on the nutritional status and learning achievement of elementary school students in Sukarami Palembang. Methods study used quasi experimental research with non -equivalent control group pretest-posttest design. This study was conducted in Palembang, South Sumatera for one year. Samples of this study were 1914 students deriving from a systematic stratified random sampling and divided into 2 groups: 986 students for the treatment samples were given 400 mg albendazole and 928 students for the controlled samples were given placebo. The result of this study found that there was a decrease in the prevalence of worm infection both in the treatment and controlled samples. However the number of infected students in the treatment samples decreased. The implication research is the drug albendazole worm declared as the most effective drug to treat intestinal worm infections.
Strandberg, G; Larsson, A; Lipcsey, M; Berglund, L; Eriksson, M
2014-03-01
Intraosseous (IO) access is used in emergency situations to allow rapid initiation of treatment. IO access is also sometimes used for blood sampling, although data on accuracy of such sampling in critical illness are limited. There is also a potential risk that bone marrow fragments in IO samples may damage laboratory equipment. It is ethically questionable to perform a simultaneous comparison between IO and arterial/venous sampling in critically ill humans. We have, thus, studied the analytical performance of IO sampling in a porcine septic shock model using a cartridge-based analyser. Eight pigs with endotoxin-induced septic shock were sampled hourly for 6 h, and analysed for blood gases, acid base status, haemoglobin, glucose and lactate using point of care instruments. Samples were taken from three IO cannulae (tibia bilaterally, one with infusion, and humerus), one arterial and one venous. An interaction test was used to assess changes in agreement between methods over time. Bland–Altman plots were constructed to study bias between methods. There were, to a varying extent, differences between IO and arterial/venous levels for all studied variables, but agreement did not change significantly during the experiment. A general finding was a large dispersion of differences between methods. IO sample values should be treated with caution in this setting but may add useful information to the clinical picture. The tibia or humerus may be used for sampling. IO infusion decreases agreement, thus sampling during infusion should be avoided.
Sample handling for mass spectrometric proteomic investigations of human sera.
West-Nielsen, Mikkel; Høgdall, Estrid V; Marchiori, Elena; Høgdall, Claus K; Schou, Christian; Heegaard, Niels H H
2005-08-15
Proteomic investigations of sera are potentially of value for diagnosis, prognosis, choice of therapy, and disease activity assessment by virtue of discovering new biomarkers and biomarker patterns. Much debate focuses on the biological relevance and the need for identification of such biomarkers while less effort has been invested in devising standard procedures for sample preparation and storage in relation to model building based on complex sets of mass spectrometric (MS) data. Thus, development of standardized methods for collection and storage of patient samples together with standards for transportation and handling of samples are needed. This requires knowledge about how sample processing affects MS-based proteome analyses and thereby how nonbiological biased classification errors are avoided. In this study, we characterize the effects of sample handling, including clotting conditions, storage temperature, storage time, and freeze/thaw cycles, on MS-based proteomics of human serum by using principal components analysis, support vector machine learning, and clustering methods based on genetic algorithms as class modeling and prediction methods. Using spiking to artificially create differentiable sample groups, this integrated approach yields data that--even when working with sample groups that differ more than may be expected in biological studies--clearly demonstrate the need for comparable sampling conditions for samples used for modeling and for the samples that are going into the test set group. Also, the study emphasizes the difference between class prediction and class comparison studies as well as the advantages and disadvantages of different modeling methods.
Dobbs, N A; Twelves, C J; Ramirez, A J; Towlson, K E; Gregory, W M; Richards, M A
1993-01-01
We have studied the practical implications and acceptability to patients of pharmacokinetic studies in 34 women receiving anthracyclines for advanced breast cancer. The following parameters were recorded: age, ECOG performance status, psychological state (Rotterdam Symptom Checklist), cytotoxic drug and dose, number of venepunctures for treatment and sampling, and time when the sampling cannula was removed. Immediately after finishing pharmacokinetic sampling, patients completed a questionnaire which revealed that (i) all patients understood sampling was for research, (ii) 35% of patients experienced problems with sampling, (iii) benefits from participation were perceived by 56% of patients. Of 20 patients later questioned after completion of their treatment course, 40% recalled difficulties with blood sampling. Factors identifying in advance those patients who tolerate pharmacokinetic studies poorly were not identified but the number of venepunctures should be minimised. Patients may also perceive benefits from 'non-therapeutic' research.
Horizons and opportunities in lunar sample science
NASA Technical Reports Server (NTRS)
1985-01-01
The Moon is the cornerstone of planetary science. Lunar sample studies were fundamental in developing an understanding of the early evolution and continued development of planetary bodies, and have led to major revisions in understanding of processes for the accumulation of planetesimals and the formation of planets. Studies of lunar samples have increased an understanding of impact cratering, meteoroid and micrometeoroid fluxes, the interaction of planetary surfaces with radiations and particles, and even the history of the Sun. The lunar sample research program was especially productive, but by no means have all the important answers been determined; continued study of lunar samples will further illuminate the shadows of our knowledge about the solar system. Further, the treasures returned through the Apollo program provide information that is required for a return to the Moon, beginning with new exploration (Lunar Geoscience Observer (LGO)), followed by intensive study (new sample return missions), and eventually culminating in a lunar base and lunar resource utilization.
Alì, Greta; Borrelli, Nicla; Riccardo, Giannini; Proietti, Agnese; Pelliccioni, Serena; Niccoli, Cristina; Boldrini, Laura; Lucchi, Marco; Mussi, Alfredo; Fontanini, Gabriella
2013-11-01
Malignant pleural mesothelioma (MPM) is a highly aggressive neoplasm associated with asbestos exposure. Currently, the molecular mechanisms that induce MPM development are still unknown. The purpose of this study was to identify new molecular biomarkers for mesothelial carcinogenesis. We analyzed a panel of 84 genes involved in extracellular matrix remodeling and cell adhesion by polymerase chain reaction (PCR) array in 15 samples of epithelioid mesothelioma and 10 samples of reactive mesothelial hyperplasia (MH; 3 of 25 samples were inadequate for mRNA analysis). To validate the differentially expressed genes identified by PCR array, we analyzed 27 more samples by immunohistochemistry, in addition to the 25 samples already studied. Twenty-five genes were differentially expressed in MPM and MH by PCR array. Of these we studied matrix metalloproteinase 7 (MMP7), MMP14, CD44, and integrin, alpha3 expression by immunohistochemistry in 26 epithelioid MPM and 26 MH samples from the entire series of 52 cases. We observed higher MMP14 and integrin, alpha3 expression in MPM samples compared with MH samples (p = 0.000002 and p = 0.000002, respectively). Conversely, CD44 expression was low in most (57.7%) mesothelioma samples but only in 11.5% of the MH samples (p = 0.0013). As regards MMP7, we did not observe differential expression between MH and MPM samples. We have extensively studied genes involved in cell adhesion and extracellular matrix remodeling in MPM and MH samples, gaining new insight into the pathophysiology of mesothelioma. Moreover, our data suggest that these factors could be potential biomarkers for MPM.
Buhule, Olive D; Minster, Ryan L; Hawley, Nicola L; Medvedovic, Mario; Sun, Guangyun; Viali, Satupaitea; Deka, Ranjan; McGarvey, Stephen T; Weeks, Daniel E
2014-01-01
Batch effects in DNA methylation microarray experiments can lead to spurious results if not properly handled during the plating of samples. Two pilot studies examining the association of DNA methylation patterns across the genome with obesity in Samoan men were investigated for chip- and row-specific batch effects. For each study, the DNA of 46 obese men and 46 lean men were assayed using Illumina's Infinium HumanMethylation450 BeadChip. In the first study (Sample One), samples from obese and lean subjects were examined on separate chips. In the second study (Sample Two), the samples were balanced on the chips by lean/obese status, age group, and census region. We used methylumi, watermelon, and limma R packages, as well as ComBat, to analyze the data. Principal component analysis and linear regression were, respectively, employed to identify the top principal components and to test for their association with the batches and lean/obese status. To identify differentially methylated positions (DMPs) between obese and lean males at each locus, we used a moderated t-test. Chip effects were effectively removed from Sample Two but not Sample One. In addition, dramatic differences were observed between the two sets of DMP results. After "removing" batch effects with ComBat, Sample One had 94,191 probes differentially methylated at a q-value threshold of 0.05 while Sample Two had zero differentially methylated probes. The disparate results from Sample One and Sample Two likely arise due to the confounding of lean/obese status with chip and row batch effects. Even the best possible statistical adjustments for batch effects may not completely remove them. Proper study design is vital for guarding against spurious findings due to such effects.
Buhule, Olive D.; Minster, Ryan L.; Hawley, Nicola L.; Medvedovic, Mario; Sun, Guangyun; Viali, Satupaitea; Deka, Ranjan; McGarvey, Stephen T.; Weeks, Daniel E.
2014-01-01
Background: Batch effects in DNA methylation microarray experiments can lead to spurious results if not properly handled during the plating of samples. Methods: Two pilot studies examining the association of DNA methylation patterns across the genome with obesity in Samoan men were investigated for chip- and row-specific batch effects. For each study, the DNA of 46 obese men and 46 lean men were assayed using Illumina's Infinium HumanMethylation450 BeadChip. In the first study (Sample One), samples from obese and lean subjects were examined on separate chips. In the second study (Sample Two), the samples were balanced on the chips by lean/obese status, age group, and census region. We used methylumi, watermelon, and limma R packages, as well as ComBat, to analyze the data. Principal component analysis and linear regression were, respectively, employed to identify the top principal components and to test for their association with the batches and lean/obese status. To identify differentially methylated positions (DMPs) between obese and lean males at each locus, we used a moderated t-test. Results: Chip effects were effectively removed from Sample Two but not Sample One. In addition, dramatic differences were observed between the two sets of DMP results. After “removing” batch effects with ComBat, Sample One had 94,191 probes differentially methylated at a q-value threshold of 0.05 while Sample Two had zero differentially methylated probes. The disparate results from Sample One and Sample Two likely arise due to the confounding of lean/obese status with chip and row batch effects. Conclusion: Even the best possible statistical adjustments for batch effects may not completely remove them. Proper study design is vital for guarding against spurious findings due to such effects. PMID:25352862
Valder, Joshua F.; Delzer, Gregory C.; Bender, David A.; Price, Curtis V.
2011-01-01
This report presents finished-water matrix-spike recoveries of 270 anthropogenic organic compounds with and without the addition of ascorbic acid to preserve water samples containing free chlorine. Percent recoveries were calculated using analytical results from a study conducted during 2004-10 for the National Water-Quality Assessment (NAWQA) Program of the U.S. Geological Survey (USGS). The study was intended to characterize the effect of quenching on finished-water matrix-spike recoveries and to better understand the potential oxidation and transformation of 270 anthropogenic organic compounds. The anthropogenic organic compounds studied include those on analytical schedules 1433, 2003, 2033, 2060, 2020, and 4024 of the USGS National Water Quality Laboratory. Three types of samples were collected from 34 NAWQA locations across the Nation: (1) quenched finished-water samples (not spiked), (2) quenched finished-water matrix-spike samples, and (3) nonquenched finished-water matrix-spike samples. Percent recoveries of anthropogenic organic compounds in quenched and nonquenched finished-water matrix-spike samples are presented. Comparisons of percent recoveries between quenched and nonquenched spiked samples can be used to show how quenching affects finished-water samples. A maximum of 18 surface-water and 34 groundwater quenched finished-water matrix-spike samples paired with nonquenched finished-water matrix-spike samples were analyzed. Percent recoveries for the study are presented in two ways: (1) finished-water matrix-spike samples supplied by surface-water or groundwater, and (2) by use (or source) group category for surface-water and groundwater supplies. Graphical representations of percent recoveries for the quenched and nonquenched finished-water matrix-spike samples also are presented.
Ingala, Melissa R.; Simmons, Nancy B.; Wultsch, Claudia; Krampis, Konstantinos; Speer, Kelly A.; Perkins, Susan L.
2018-01-01
The gut microbiome is a community of host-associated symbiotic microbes that fulfills multiple key roles in host metabolism, immune function, and tissue development. Given the ability of the microbiome to impact host fitness, there is increasing interest in studying the microbiome of wild animals to better understand these communities in the context of host ecology and evolution. Human microbiome research protocols are well established, but wildlife microbiome research is still a developing field. Currently, there is no standardized set of best practices guiding the collection of microbiome samples from wildlife. Gut microflora are typically sampled either by fecal collection, rectal swabbing, or by destructively sampling the intestinal contents of the host animal. Studies rarely include more than one sampling technique and no comparison of these methods currently exists for a wild mammal. Although some studies have hypothesized that the fecal microbiome is a nested subset of the intestinal microbiome, this hypothesis has not been formally tested. To address these issues, we examined guano (feces) and distal intestinal mucosa from 19 species of free-ranging bats from Lamanai, Belize, using 16S rRNA amplicon sequencing to compare microbial communities across sample types. We found that the diversity and composition of intestine and guano samples differed substantially. In addition, we conclude that signatures of host evolution are retained by studying gut microbiomes based on mucosal tissue samples, but not fecal samples. Conversely, fecal samples retained more signal of host diet than intestinal samples. These results suggest that fecal and intestinal sampling methods are not interchangeable, and that these two microbiotas record different information about the host from which they are isolated. PMID:29765359
Ingala, Melissa R; Simmons, Nancy B; Wultsch, Claudia; Krampis, Konstantinos; Speer, Kelly A; Perkins, Susan L
2018-01-01
The gut microbiome is a community of host-associated symbiotic microbes that fulfills multiple key roles in host metabolism, immune function, and tissue development. Given the ability of the microbiome to impact host fitness, there is increasing interest in studying the microbiome of wild animals to better understand these communities in the context of host ecology and evolution. Human microbiome research protocols are well established, but wildlife microbiome research is still a developing field. Currently, there is no standardized set of best practices guiding the collection of microbiome samples from wildlife. Gut microflora are typically sampled either by fecal collection, rectal swabbing, or by destructively sampling the intestinal contents of the host animal. Studies rarely include more than one sampling technique and no comparison of these methods currently exists for a wild mammal. Although some studies have hypothesized that the fecal microbiome is a nested subset of the intestinal microbiome, this hypothesis has not been formally tested. To address these issues, we examined guano (feces) and distal intestinal mucosa from 19 species of free-ranging bats from Lamanai, Belize, using 16S rRNA amplicon sequencing to compare microbial communities across sample types. We found that the diversity and composition of intestine and guano samples differed substantially. In addition, we conclude that signatures of host evolution are retained by studying gut microbiomes based on mucosal tissue samples, but not fecal samples. Conversely, fecal samples retained more signal of host diet than intestinal samples. These results suggest that fecal and intestinal sampling methods are not interchangeable, and that these two microbiotas record different information about the host from which they are isolated.
Elliott, Sarah M.; Erickson, Melinda L.
2014-01-01
The U.S. Geological Survey, in cooperation with the Minnesota Pollution Control Agency, completed a study on the occurrence of pharmaceutical compounds and other contaminants of emerging concern in shallow groundwater in non-agricultural areas of Minnesota during 2013. This report describes the study design and methods for the study on the occurrence of pharmaceuticals and other contaminants of emerging concern, and presents the data collected on pharmaceutical compounds. Samples were analyzed by the U.S. Geological Survey National Water Quality Laboratory for 110 pharmaceutical compounds using research method 9017. Samples from 21 of 45 wells had detectable concentrations of at least one of the 110 compounds analyzed. One sample contained detectable concentrations of nine compounds, which was the most detected in a single sample. Fewer than five compounds were detected in most samples. Among all samples, 27 of the 110 compounds were detected in groundwater from at least one well. Desmethyldiltiazem and nicotine were the most frequently detected compounds, each detected in 5 of 46 environmental samples (one well was sampled twice so a total of 46 environmental samples were collected from 45 wells). Caffeine had the highest detectable concentration of all the compounds at 2,060 nanograms per liter.
Analysis of the Touch-And-Go Surface Sampling Concept for Comet Sample Return Missions
NASA Technical Reports Server (NTRS)
Mandic, Milan; Acikmese, Behcet; Bayard, David S.; Blackmore, Lars
2012-01-01
This paper studies the Touch-and-Go (TAG) concept for enabling a spacecraft to take a sample from the surface of a small primitive body, such as an asteroid or comet. The idea behind the TAG concept is to let the spacecraft descend to the surface, make contact with the surface for several seconds, and then ascend to a safe location. Sampling would be accomplished by an end-effector that is active during the few seconds of surface contact. The TAG event is one of the most critical events in a primitive body sample-return mission. The purpose of this study is to evaluate the dynamic behavior of a representative spacecraft during the TAG event, i.e., immediately prior, during, and after surface contact of the sampler. The study evaluates the sample-collection performance of the proposed sampling end-effector, in this case a brushwheel sampler, while acquiring material from the surface during the contact. A main result of the study is a guidance and control (G&C) validation of the overall TAG concept, in addition to specific contributions to demonstrating the effectiveness of using nonlinear clutch mechanisms in the sampling arm joints, and increasing the length of the sampling arms to improve robustness.
Steiner, S; Neidl, A; Linhart, N; Tichy, A; Gasteiner, J; Gallob, K; Baumgartner, W; Wittek, T
2015-01-10
The objective of the study was to compare the performance of five types of stomach tubes for rumen fluid sampling. Rumen fluid was sampled in rumen fistulated cows assigned to a 5×5 Latin square study design. The pH values of samples taken by stomach tubes and via fistulas were measured; the results were compared with indwelling sensor measurements. The practicability of the stomach tubes for regular use was tested in the field. Rumen fluid samples were obtained rapidly. Volumes for transfaunation could be obtained. The pH-values of samples taken with the four out of the five tubes (Dirksen, Geishauser, tube 4 and a simple water hose used with a gag) did not show significant differences to samples taken via rumen fistulas. Mean differences ranged between -0.02 and +0.09. Samples taken with tube 4 and the water hose showed also no significant differences to pH-sensor measurements. This study demonstrates that stomach tubes are suitable for rumen fluid sampling. Tube 4 seems to be the best probe for work in the field. It was well tolerated by the animals, saliva contamination is negligible. We, therefore, conclude that the evaluation of rumen acid base status in the field is possible. British Veterinary Association.
Evaluation of Skin Surface as an Alternative Source of Reference DNA Samples: A Pilot Study.
Albujja, Mohammed H; Bin Dukhyil, Abdul Aziz; Chaudhary, Abdul Rauf; Kassab, Ahmed Ch; Refaat, Ahmed M; Babu, Saranya Ramesh; Okla, Mohammad K; Kumar, Sachil
2018-01-01
An acceptable area for collecting DNA reference sample is a part of the forensic DNA analysis development. The aim of this study was to evaluate skin surface cells (SSC) as an alternate source of reference DNA sample. From each volunteer (n = 10), six samples from skin surface areas (forearm and fingertips) and two traditional samples (blood and buccal cells) were collected. Genomic DNA was extracted and quantified then genotyped using standard techniques. The highest DNA concentration of SSC samples was collected using the tape/forearm method of collection (2.1 ng/μL). Cotton swabs moistened with ethanol yielded higher quantities of DNA than swabs moistened with salicylic acid, and it gave the highest percentage of full STR profiles (97%). This study supports the use of SSC as a noninvasive sampling technique and as a extremely useful source of DNA reference samples among certain cultures where the use of buccal swabs can be considered socially unacceptable. © 2017 American Academy of Forensic Sciences.
Nonprobability and probability-based sampling strategies in sexual science.
Catania, Joseph A; Dolcini, M Margaret; Orellana, Roberto; Narayanan, Vasudah
2015-01-01
With few exceptions, much of sexual science builds upon data from opportunistic nonprobability samples of limited generalizability. Although probability-based studies are considered the gold standard in terms of generalizability, they are costly to apply to many of the hard-to-reach populations of interest to sexologists. The present article discusses recent conclusions by sampling experts that have relevance to sexual science that advocates for nonprobability methods. In this regard, we provide an overview of Internet sampling as a useful, cost-efficient, nonprobability sampling method of value to sex researchers conducting modeling work or clinical trials. We also argue that probability-based sampling methods may be more readily applied in sex research with hard-to-reach populations than is typically thought. In this context, we provide three case studies that utilize qualitative and quantitative techniques directed at reducing limitations in applying probability-based sampling to hard-to-reach populations: indigenous Peruvians, African American youth, and urban men who have sex with men (MSM). Recommendations are made with regard to presampling studies, adaptive and disproportionate sampling methods, and strategies that may be utilized in evaluating nonprobability and probability-based sampling methods.
Evaluation of Buccal Cell Samples for Studies of Oral Microbiota.
Yu, Guoqin; Phillips, Steve; Gail, Mitchell H; Goedert, James J; Humphrys, Michael; Ravel, Jacques; Ren, Yanfang; Caporaso, Neil E
2017-02-01
The human microbiota is postulated to affect cancer risk, but collecting microbiota specimens with prospective follow-up for diseases will take time. Buccal cell samples have been obtained from mouthwash for the study of human genomic DNA in many cohort studies. Here, we evaluate the feasibility of using buccal cell samples to examine associations of human microbiota and disease risk. We obtained buccal cells from mouthwash in 41 healthy participants using a protocol that is widely employed to obtain buccal cells for the study of human DNA. We compared oral microbiota from buccal cells with that from eight other oral sample types collected by following the protocols of the Human Microbiome Project. Microbiota profiles were determined by sequencing 16S rRNA gene V3-V4 region. Compared with each of the eight other oral samples, the buccal cell samples had significantly more observed species (P < 0.002) and higher alpha diversity (Shannon index, P < 0.02). The microbial communities were more similar (smaller beta diversity) among buccal cells samples than in the other samples (P < 0.001 for 12 of 16 weighted and unweighted UniFrac distance comparisons). Buccal cell microbial profiles closely resembled saliva but were distinct from dental plaque and tongue dorsum. Stored buccal cell samples in prospective cohort studies are a promising resource to study associations of oral microbiota with disease. The feasibility of using existing buccal cell collections in large prospective cohorts allows investigations of the role of oral microbiota in chronic disease etiology in large population studies possible today. Cancer Epidemiol Biomarkers Prev; 26(2); 249-53. ©2016 AACR. ©2016 American Association for Cancer Research.
ERIC Educational Resources Information Center
Chromy, James R.
This study addressed statistical techniques that might ameliorate some of the sampling problems currently facing states with small populations participating in State National Assessment of Educational Progress (NAEP) assessments. The study explored how the application of finite population correction factors to the between-school component of…
Teacher Efficacy Beliefs: A Case Study Investigation of Core Curriculum
ERIC Educational Resources Information Center
Brown, Natalie Marie
2017-01-01
The purpose of this qualitative case study was to understand how utilizing the Core Knowledge Sequence and aligned curricular resources influenced teachers' perceived self-efficacy for a sample of Arizona elementary charter school teachers. The sample for this study was a convenience sample of 15 elementary teachers, who were currently…
The Apollo 17 samples: The Massifs and landslide
NASA Technical Reports Server (NTRS)
Ryder, Graham
1992-01-01
More than 50 kg of rock and regolith samples, a little less than half the total Apollo 17 sample mass, was collected from the highland stations at Taurus-Littrow. Twice as much material was collected from the North Massif as from the South Massif and its landslide (the apparent disproportionate collecting at the mare sites is mainly a reflection of the large size of a few individual basalt samples). Descriptions of the collection, documentation, and nature of the samples are given. A comprehensive catalog is currently being produced. Many of the samples have been intensely studied over the last 20 years and some of the rocks have become very familiar and depicted in popular works, particularly the dunite clast (72415), the troctolite sample (76535), and the station 6 boulder samples. Most of the boulder samples have been studied in Consortium mode, and many of the rake samples have received a basic petrological/geochemical characterization.
Systematic versus random sampling in stereological studies.
West, Mark J
2012-12-01
The sampling that takes place at all levels of an experimental design must be random if the estimate is to be unbiased in a statistical sense. There are two fundamental ways by which one can make a random sample of the sections and positions to be probed on the sections. Using a card-sampling analogy, one can pick any card at all out of a deck of cards. This is referred to as independent random sampling because the sampling of any one card is made without reference to the position of the other cards. The other approach to obtaining a random sample would be to pick a card within a set number of cards and others at equal intervals within the deck. Systematic sampling along one axis of many biological structures is more efficient than random sampling, because most biological structures are not randomly organized. This article discusses the merits of systematic versus random sampling in stereological studies.
Huang, Liping; Crino, Michelle; Wu, Jason Hy; Woodward, Mark; Land, Mary-Anne; McLean, Rachael; Webster, Jacqui; Enkhtungalag, Batsaikhan; Nowson, Caryl A; Elliott, Paul; Cogswell, Mary; Toft, Ulla; Mill, Jose G; Furlanetto, Tania W; Ilich, Jasminka Z; Hong, Yet Hoi; Cohall, Damian; Luzardo, Leonella; Noboa, Oscar; Holm, Ellen; Gerbes, Alexander L; Senousy, Bahaa; Pinar Kara, Sonat; Brewster, Lizzy M; Ueshima, Hirotsugu; Subramanian, Srinivas; Teo, Boon Wee; Allen, Norrina; Choudhury, Sohel Reza; Polonia, Jorge; Yasuda, Yoshinari; Campbell, Norm Rc; Neal, Bruce; Petersen, Kristina S
2016-09-21
Methods based on spot urine samples (a single sample at one time-point) have been identified as a possible alternative approach to 24-hour urine samples for determining mean population salt intake. The aim of this study is to identify a reliable method for estimating mean population salt intake from spot urine samples. This will be done by comparing the performance of existing equations against one other and against estimates derived from 24-hour urine samples. The effects of factors such as ethnicity, sex, age, body mass index, antihypertensive drug use, health status, and timing of spot urine collection will be explored. The capacity of spot urine samples to measure change in salt intake over time will also be determined. Finally, we aim to develop a novel equation (or equations) that performs better than existing equations to estimate mean population salt intake. A systematic review and meta-analysis of individual participant data will be conducted. A search has been conducted to identify human studies that report salt (or sodium) excretion based upon 24-hour urine samples and spot urine samples. There were no restrictions on language, study sample size, or characteristics of the study population. MEDLINE via OvidSP (1946-present), Premedline via OvidSP, EMBASE, Global Health via OvidSP (1910-present), and the Cochrane Library were searched, and two reviewers identified eligible studies. The authors of these studies will be invited to contribute data according to a standard format. Individual participant records will be compiled and a series of analyses will be completed to: (1) compare existing equations for estimating 24-hour salt intake from spot urine samples with 24-hour urine samples, and assess the degree of bias according to key demographic and clinical characteristics; (2) assess the reliability of using spot urine samples to measure population changes in salt intake overtime; and (3) develop a novel equation that performs better than existing equations to estimate mean population salt intake. The search strategy identified 538 records; 100 records were obtained for review in full text and 73 have been confirmed as eligible. In addition, 68 abstracts were identified, some of which may contain data eligible for inclusion. Individual participant data will be requested from the authors of eligible studies. Many equations for estimating salt intake from spot urine samples have been developed and validated, although most have been studied in very specific settings. This meta-analysis of individual participant data will enable a much broader understanding of the capacity for spot urine samples to estimate population salt intake.
Evaluation of two types of swabs for sampling allograft musculoskeletal tissue.
Varettas, Kerry
2015-01-01
Allograft musculoskeletal tissue is commonly sampled by a swab for bioburden screening. To determine if bioburden recovery could be improved at the pre-analytical stage, two swab systems were evaluated: the Amies gel swab and the ESwab. In vitro studies were performed to determine the recovery of each swab system with <100 colony-forming unit of challenge organisms using inoculated swabs and by sampling inoculated femoral heads. The standard culture protocol used in this laboratory was also evaluated after sampling of inoculated femoral heads. A prospective study was performed with both swab systems used in parallel to sample cadaveric allograft musculoskeletal tissue. The challenge organisms could be recovered from the in vitro inoculated studies. The standard culture protocol in this laboratory recovered all challenge organisms from both swab systems. One hundred and six paired Amies and ESwabs were collected from eight cadaveric donors with skin commensals the predominant isolates. The sampling of an inoculated femoral head was included to reflect routine swab sampling practice as was the inclusion of the standard method used in this laboratory. This appears to be the first study to compare Amies gel swabs with ESwabs to sample allograft femoral heads and in a prospective study with cadaveric allograft musculoskeletal tissue. Other comparative studies of swab systems have used a much higher inoculum to mimic an infection; however, sepsis is an exclusion criterion for allograft donors. It was found that the Amies gel swab and ESwab are both suitable sampling devices for bioburden testing of allograft musculoskeletal tissue. © 2014 Royal Australasian College of Surgeons.
DNA barcoding using skin exuviates can improve identification and biodiversity studies of snakes.
Khedkar, Trupti; Sharma, Rashmi; Tiknaik, Anita; Khedkar, Gulab; Naikwade, Bhagwat S; Ron, Tetsuzan Benny; Haymer, David
2016-01-01
Snakes represent a taxonomically underdeveloped group of animals in India with a lack of experts and incomplete taxonomic descriptions being the main deterrents to advances in this area. Molecular taxonomic approaches using DNA barcoding could aid in snake identification as well as studies of biodiversity. Here a non-invasive sampling method using DNA barcoding is tested using skin exuviates. Taxonomically authenticated samples were collected and tested for validation and comparisons to unknown snake exuviate samples. This approach was also used to construct the first comprehensive study targeting the snake species from Maharashtra state in India. A total of 92 skin exuviate samples were collected and tested for this study. Of these, 81 samples were successfully DNA barcoded and compared with unknown samples for assignment of taxonomic identity. Good quality DNA was obtained irrespective of age and quality of the exuviate material, and all unknown samples were successfully identified. A total of 23 species of snakes were identified, six of which were in the list of Endangered species (Red Data Book). Intra- and inter-specific distance values were also calculated, and these were sufficient to allow discrimination among species and between species without ambiguity in most cases. Two samples were suspected to represent cryptic species based on deep K2P divergence values (>3%), and one sample could be identified to the genus level only. Eleven samples failed to amplify COI sequences, suggesting the need for alternative PCR primer pairs. This study clearly documents how snake skin exuviates can be used for DNA barcoding, estimates of diversity and population genetic structuring in a noninvasive manner.
Improvement in the stability of serum samples stored in an automated refrigerated module.
Parra-Robert, Marina; Rico-Santana, Naira; Alcaraz-Quiles, José; Sandalinas, Silvia; Fernández, Esther; Falcón, Isabel; Pérez-Riedweg, Margarita; Bedini, Josep Lluís
2016-12-01
In clinical laboratories it is necessary to know for how long the analytes are stable in the samples with specific storage conditions. Our laboratory has implemented the new Aptio Automation System (AAS) (Siemens Healthcare Diagnostics) where the analyzed samples are stored in a refrigerated storage module (RSM) after being sealed. The aim of the study was to evaluate the stability of serum samples with the AAS and comparing the results with a previous study using a conventional refrigerated system. Serum samples from a total of 50 patients were collected and for each of them 27 biochemical analytes were analyzed. The samples were divided in 5 sets of 10 samples. Each set was re-analyzed at one of the following times: 24, 48, 72, 96 and 120h. Stability was evaluated according to the Total Limit of Change (TLC) criteria, which combine both analytical and biologic variation. A total of 26 out of 27 analytes were stable at the end of the study according to TLC criteria. Lactate dehydrogenase was not stable at 48h observing a decrease in its concentration until the end of the study. In the previous study (conventional storage system) 9 biochemical analytes were not stable with an increase of their levels due to the evaporation process. The RSM connected to the AAS improves the stability of serum samples. This system avoids the evaporation process due to the sealing of samples and allows better control of the samples during their storage. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
A computer program for sample size computations for banding studies
Wilson, K.R.; Nichols, J.D.; Hines, J.E.
1989-01-01
Sample sizes necessary for estimating survival rates of banded birds, adults and young, are derived based on specified levels of precision. The banding study can be new or ongoing. The desired coefficient of variation (CV) for annual survival estimates, the CV for mean annual survival estimates, and the length of the study must be specified to compute sample sizes. A computer program is available for computation of the sample sizes, and a description of the input and output is provided.
OSL technique for studies of jasper samples
NASA Astrophysics Data System (ADS)
Teixeira, Maria Inês; Caldas, Linda V. E.
2014-02-01
Jasper samples (green, red, brown, ocean and striped) were studied in relation to their optically stimulated luminescence (OSL) dosimetric properties, in this work. Since 2000, the radiation metrology group of IPEN has studied different stones as new materials for application in high-dose dosimetry. The jasper samples were exposed to different radiation doses, using the Gamma-cell 220 system (60Co) of IPEN. Calibration curves were obtained for the jasper samples between 50 Gy and 300 kGy. The reproducibility of the OSL response and the lower detection doses were determined. All five types of jasper samples showed their usefulness as irradiation indicators and as high-dose dosimeters, using the OSL technique.
Smith, Joseph M.; Wells, Sarah P.; Mather, Martha E.; Muth, Robert M.
2014-01-01
When researchers and managers initiate sampling on a new stream or river system, they do not know how effective each gear type is and whether their sampling effort is adequate. Although the types and amount of gear may be different for other studies, systems, and research questions, the five-step process described here for making sampling decisions and evaluating sampling efficiency can be applied widely to any system to restore, manage, and conserve aquatic ecosystems. It is believed that incorporating this gear-evaluation process into a wide variety of studies and ecosystems will increase rigour within and across aquatic biodiversity studies.
Mayer, B; Muche, R
2013-01-01
Animal studies are highly relevant for basic medical research, although their usage is discussed controversially in public. Thus, an optimal sample size for these projects should be aimed at from a biometrical point of view. Statistical sample size calculation is usually the appropriate methodology in planning medical research projects. However, required information is often not valid or only available during the course of an animal experiment. This article critically discusses the validity of formal sample size calculation for animal studies. Within the discussion, some requirements are formulated to fundamentally regulate the process of sample size determination for animal experiments.
Integration of DNA sample collection into a multi-site birth defects case-control study.
Rasmussen, Sonja A; Lammer, Edward J; Shaw, Gary M; Finnell, Richard H; McGehee, Robert E; Gallagher, Margaret; Romitti, Paul A; Murray, Jeffrey C
2002-10-01
Advances in quantitative analysis and molecular genotyping have provided unprecedented opportunities to add biological sampling and genetic information to epidemiologic studies. The purpose of this article is to describe the incorporation of DNA sample collection into the National Birth Defects Prevention Study (NBDPS), an ongoing case-control study in an eight-state consortium with a primary goal to identify risk factors for birth defects. Babies with birth defects are identified through birth defects surveillance systems in the eight participating centers. Cases are infants with one or more of over 30 major birth defects. Controls are infants without defects from the same geographic area. Epidemiologic information is collected through an hour-long interview with mothers of both cases and controls. We added the collection of buccal cytobrush DNA samples for case-infants, control-infants, and their parents to this study. We describe here the methods by which the samples have been collected and processed, establishment of a centralized resource for DNA banking, and quality control, database management, access, informed consent, and confidentiality issues. Biological sampling and genetic analyses are important components to epidemiologic studies of birth defects aimed at identifying risk factors. The DNA specimens collected in this study can be used for detection of mutations, study of polymorphic variants that confer differential susceptibility to teratogens, and examination of interactions among genetic risk factors. Information on the methods used and issues faced by the NBDPS may be of value to others considering the addition of DNA sampling to epidemiologic studies.
Filter forensics: microbiota recovery from residential HVAC filters.
Maestre, Juan P; Jennings, Wiley; Wylie, Dennis; Horner, Sharon D; Siegel, Jeffrey; Kinney, Kerry A
2018-01-30
Establishing reliable methods for assessing the microbiome within the built environment is critical for understanding the impact of biological exposures on human health. High-throughput DNA sequencing of dust samples provides valuable insights into the microbiome present in human-occupied spaces. However, the effect that different sampling methods have on the microbial community recovered from dust samples is not well understood across sample types. Heating, ventilation, and air conditioning (HVAC) filters hold promise as long-term, spatially integrated, high volume samplers to characterize the airborne microbiome in homes and other climate-controlled spaces. In this study, the effect that dust recovery method (i.e., cut and elution, swabbing, or vacuuming) has on the microbial community structure, membership, and repeatability inferred by Illumina sequencing was evaluated. The results indicate that vacuum samples captured higher quantities of total, bacterial, and fungal DNA than swab or cut samples. Repeated swab and vacuum samples collected from the same filter were less variable than cut samples with respect to both quantitative DNA recovery and bacterial community structure. Vacuum samples captured substantially greater bacterial diversity than the other methods, whereas fungal diversity was similar across all three methods. Vacuum and swab samples of HVAC filter dust were repeatable and generally superior to cut samples. Nevertheless, the contribution of environmental and human sources to the bacterial and fungal communities recovered via each sampling method was generally consistent across the methods investigated. Dust recovery methodologies have been shown to affect the recovery, repeatability, structure, and membership of microbial communities recovered from dust samples in the built environment. The results of this study are directly applicable to indoor microbiota studies utilizing the filter forensics approach. More broadly, this study provides a better understanding of the microbial community variability attributable to sampling methodology and helps inform interpretation of data collected from other types of dust samples collected from indoor environments.
Fish stomach contents in benthic macroinvertebrate assemblage assessments.
Tupinambás, T H; Pompeu, P S; Gandini, C V; Hughes, R M; Callisto, M
2015-01-01
The choice of sampling gears to assess benthic macroinvertebrate communities depends on environmental characteristics, study objectives, and cost effectiveness. Because of the high foraging capacity and diverse habitats and behaviors of benthophagous fishes, their stomach contents may offer a useful sampling tool in studies of benthic macroinvertebrates, especially in large, deep, fast rivers that are difficult to sample with traditional sediment sampling gear. Our objective was to compare the benthic macroinvertebrate communities sampled from sediments with those sampled from fish stomachs. We collected benthic macroinvertebrates and fish from three different habitat types (backwater, beach, riffle) in the wet season, drying season, and dry season along a single reach of the Grande River (Paraná River Basin, southeast Brazil). We sampled sediments through use of a Petersen dredge (total of 216 grabs) and used gill nets to sample fish (total of 36 samples). We analyzed the stomach contents of three commonly occurring benthophagous fish species (Eigenmannia virescens, Iheringichthys labrosus, Leporinus amblyrhynchus). Chironomids dominated in both sampling methods. Macroinvertebrate taxonomic composition and abundances from fish stomachs differed from those from sediment samples, but less so from riffles than from backwater and beach habitats. Macroinvertebrate taxa from E. virescens stomachs were more strongly correlated with sediment samples from all three habitats than were those from the other two species. The species accumulation curves and higher mean dispersion values, compared with with sediment samples suggest that E. virescens is more efficient than sediment samples and the other fish studied at collecting benthic taxa. We conclude that by analyzing the stomach contents of benthophagous fishes it is possible to assess important characteristics of benthic communities (dispersion, taxonomic composition and diversity). This is especially true for studies that only sample fish assemblages to evaluate aquatic ecosystem impacts. Therefore, this approach can be useful to amplify assessments of human impacts, and to incorporate additional bioindicators.
NASA Astrophysics Data System (ADS)
Derz, U.; Joffre, E.; Perkinson, M.-C.; Huesing, J.; Beyer, F.; Sanchez Perez, J. M.
2018-04-01
This paper presents the identified most promising chemical and electric propulsion architecture options of the Mars Sample Return (MSR) orbiter identified during the recent ESA MSR Architecture Assessment Study.
Do Research Findings Apply to My Students? Examining Study Samples and Sampling
ERIC Educational Resources Information Center
Cook, Bryan G.; Cook, Lysandra
2017-01-01
Special educators are urged to use research findings to inform their instruction in order to improve student outcomes. However, it can be difficult to tell whether and how research findings apply to one's own students. In this article, we discuss how special educators can consider the samples and the sampling methods in studies to examine the…
The Relationship between Sample Sizes and Effect Sizes in Systematic Reviews in Education
ERIC Educational Resources Information Center
Slavin, Robert; Smith, Dewi
2009-01-01
Research in fields other than education has found that studies with small sample sizes tend to have larger effect sizes than those with large samples. This article examines the relationship between sample size and effect size in education. It analyzes data from 185 studies of elementary and secondary mathematics programs that met the standards of…
Comparative Financial Statistics for Public Two-Year Colleges: FY 1995 Peer Groups Sample.
ERIC Educational Resources Information Center
Meeker, Bradley
Comparative financial information derived from a national sample of 405 two-year colleges is presented in this report for fiscal year 1994-95, including data for the national sample and for 6groups of peer institutions. The first section provides introductory information on the annual study, discussing the study sample and the use of study…
A re-evaluation of a case-control model with contaminated controls for resource selection studies
Christopher T. Rota; Joshua J. Millspaugh; Dylan C. Kesler; Chad P. Lehman; Mark A. Rumble; Catherine M. B. Jachowski
2013-01-01
A common sampling design in resource selection studies involves measuring resource attributes at sample units used by an animal and at sample units considered available for use. Few models can estimate the absolute probability of using a sample unit from such data, but such approaches are generally preferred over statistical methods that estimate a relative probability...
ERIC Educational Resources Information Center
Dykiert, Dominika; Gale, Catharine R.; Deary, Ian J.
2009-01-01
This study investigated the possibility that apparent sex differences in IQ are at least partly created by the degree of sample restriction from the baseline population. We used a nationally representative sample, the 1970 British Cohort Study. Sample sizes varied from 6518 to 11,389 between data-collection sweeps. Principal components analysis of…
The purpose of this SOP is to establish a uniform procedure for the collection of indoor floor dust samples in the field. This procedure was followed to ensure consistent data retrieval of dust samples during the Arizona NHEXAS project and the "Border" study. Keywords: field; va...
Kouassi-M'Bengue, Alphonsine; Koffi, Stephane; Manizan, Pascale; Ouattara, Abdoulaye; N'Douba, Adele Kacou; Dosso, Mireille
2008-01-01
Assurance quality is important in medical laboratory, but in Africa, few laboratories are involved in this process. The aim of this study was to assess biological sampling's quality in a bacteriological laboratory. A cross sectional study was undertaken in medical bacteriological laboratory of Côte d' Ivoire Institute Pasteur during 6 months. All urines, saddles, and bronchial expectorations collected from ambulatory patients during this period were included in the study. The quality of urine's, saddles and bronchial expectorations' sampling for a bacteriological analysis was evaluated. An interview based on Guidelines of good laboratories practices and referential ISO 15189 was used. A total of 300 samples were indexed. On a total of 300 recorded biological samples, 224 (74.7%) were not in conformity. In 87.5% of the cases of nonconformities, an antibiotic's treatment were preliminary instituted before the sampling. Corrective actions were carried in the laboratory on 30 samples with 56.6% for the urines, 26.7% for the saddles and 16.7% for the bronchial expectorations. At the end of this study, it arises that the quality of the biological sampling received at the medical bacteriology laboratory need to be improved.
NASA Astrophysics Data System (ADS)
Ismail, R.; Mahadi, Z. A.; Ishak, I. S.
2018-04-01
This paper presented the study on the effect of carbon black as filler to the mechanical properties of natural rubber for base isolation system. This study used the five formulations with the different amount of carbon black filler for every sample. The samples were tested for tensile, hardness and resilience test. The samples were cured or vulcanized at 1500C for 23 minutes for every formulation. The filler used in this study was the carbon black filler with type N660. The tensile test was done to determine the ability of the sample in term of the elongation with the load at break. The hardness test, it has been done to determine the ability of the sample to resist the load. This hardness was measured in the unit of IRHD. The resilience test was being done to determine the properties of the sample in term of rebound characteristics. The finding of this study showed that, the high the loading of carbon black filler, the high the tensile strength of the sample and the high the hardness of the sample. In term of resilience, it was inversely proportional to the loading of the carbon black filler.
The Portuguese adaptation of the Gudjonsson Suggestibility Scale (GSS1) in a sample of inmates.
Pires, Rute; Silva, Danilo R; Ferreira, Ana Sousa
2014-01-01
This paper comprises two studies which address the validity of the Portuguese adaptation of the Gudjonsson Suggestibility Scale, GSS1. In study 1, the means and standard deviations for the suggestibility results of a sample of Portuguese inmates (N=40, Mage=37.5 years, SD=8.1) were compared to those of a sample of Icelandic inmates (Gudjonsson, 1997; Gudjonsson & Sigurdsson, 1996). Portuguese inmates' results were in line with the original results. In study 2, the means and standard deviations for the suggestibility results of the sample of Portuguese inmates were compared to those of a general Portuguese population sample (N=57, Mage=36.1 years, SD=12.7). The forensic sample obtained significantly higher scores in suggestibility measures than the general population sample. ANOVA confirmed that the increased suggestibility in the inmates sample was due to the limited memory capacity of this latter group. Given that the results of both studies 1 and 2 are in keeping with the author's original results (Gudjonsson, 1997), this may be regarded as a confirmation of the validity of the Portuguese GSS1. Copyright © 2013 Elsevier Ltd. All rights reserved.
Nasser, Laila A.
2014-01-01
Several studies have shown that canned meat products may be contaminated with fungal elements, bacteria and even heavy metals which may occur during the transportation, storage and handling processes. We conducted this study to determine the fungal, microbial and heavy metal contents of canned meats in Saudi Arabia. Of the 13 canned meat samples studied, Aspergillus and Penicillium were found in more than 70% of the total samples. Sequences of Penicillium species isolated from meat samples generated a phylogenetic tree which shows that the studied isolates were clustered in four groups. No bacterial contamination was noted in all of the samples. Nine of the 13 samples had iron concentrations above the permissible limit. All samples had zinc and copper levels below the maximum permissible limit. Four samples had cadmium levels above the maximum permissible level. All samples had levels of lead above the maximum permissible levels. These results indicate that fungal elements and higher levels of heavy metals such as lead and cadmium can be found in canned meat products. This may pose as a real danger to consumers, since canned meat products are readily accessible and convenient in Saudi Arabia. PMID:26288552
Designing occupancy studies: general advice and allocating survey effort
MacKenzie, D.I.; Royle, J. Andrew
2005-01-01
1. The fraction of sampling units in a landscape where a target species is present (occupancy) is an extensively used concept in ecology. Yet in many applications the species will not always be detected in a sampling unit even when present, resulting in biased estimates of occupancy. Given that sampling units are surveyed repeatedly within a relatively short timeframe, a number of similar methods have now been developed to provide unbiased occupancy estimates. However, practical guidance on the efficient design of occupancy studies has been lacking. 2. In this paper we comment on a number of general issues related to designing occupancy studies, including the need for clear objectives that are explicitly linked to science or management, selection of sampling units, timing of repeat surveys and allocation of survey effort. Advice on the number of repeat surveys per sampling unit is considered in terms of the variance of the occupancy estimator, for three possible study designs. 3. We recommend that sampling units should be surveyed a minimum of three times when detection probability is high (> 0.5 survey-1), unless a removal design is used. 4. We found that an optimal removal design will generally be the most efficient, but we suggest it may be less robust to assumption violations than a standard design. 5. Our results suggest that for a rare species it is more efficient to survey more sampling units less intensively, while for a common species fewer sampling units should be surveyed more intensively. 6. Synthesis and applications. Reliable inferences can only result from quality data. To make the best use of logistical resources, study objectives must be clearly defined; sampling units must be selected, and repeated surveys timed appropriately; and a sufficient number of repeated surveys must be conducted. Failure to do so may compromise the integrity of the study. The guidance given here on study design issues is particularly applicable to studies of species occurrence and distribution, habitat selection and modelling, metapopulation studies and monitoring programmes.
Molecular detection of fungi of public health importance in wild animals from Southern Brazil.
Losnak, Debora O; Rocha, Francielle R; Almeida, Barbara S; Batista, Keila Z S; Althoff, Sérgio L; Haupt, Josiane; Ruiz, Luciana S; Anversa, Laís; Lucheis, Simone B; Paiz, Laís M; Donalisio, Maria Rita; Richini Pereira, Virginia B
2018-07-01
Some animals have an important relationship with fungal infections, and searching for pathogens in animal samples may be an opportunity for eco-epidemiological research. Since studies involving wildlife are generally restricted, using samples from road kills is an alternative. The aim of this study was to verify whether pathogenic fungi of public health importance occur in wildlife road kills from Santa Catarina State, Brazil. Organ samples (n = 1063) from 297 animals were analysed according to Polymerase Chain Reaction (PCR) using universal primers to detect fungi in general and, subsequently, using primers specific to Paracoccidioides brasiliensis, Histoplasma capsulatum and Cryptococcus spp. There were 102 samples positive for fungal species. Eight samples were positive for P. brasiliensis, three samples were positive for Cryptococcus spp. and one sample had coinfection by these two fungi. No sample was positive for Histoplasma spp. according to the molecular detection. Genetic sequencing allowed the identification of Fungal sp. in 89 samples, Cryptococcus neoformans in two samples and Aspergillus penicillioides in three samples. This study shows the importance of wild animals in the epidemiology of fungal infections and assists in the mapping of pathogen occurrence in a region that was not previously evaluated. © 2018 Blackwell Verlag GmbH.
Galway, Lp; Bell, Nathaniel; Sae, Al Shatari; Hagopian, Amy; Burnham, Gilbert; Flaxman, Abraham; Weiss, Wiliam M; Rajaratnam, Julie; Takaro, Tim K
2012-04-27
Mortality estimates can measure and monitor the impacts of conflict on a population, guide humanitarian efforts, and help to better understand the public health impacts of conflict. Vital statistics registration and surveillance systems are rarely functional in conflict settings, posing a challenge of estimating mortality using retrospective population-based surveys. We present a two-stage cluster sampling method for application in population-based mortality surveys. The sampling method utilizes gridded population data and a geographic information system (GIS) to select clusters in the first sampling stage and Google Earth TM imagery and sampling grids to select households in the second sampling stage. The sampling method is implemented in a household mortality study in Iraq in 2011. Factors affecting feasibility and methodological quality are described. Sampling is a challenge in retrospective population-based mortality studies and alternatives that improve on the conventional approaches are needed. The sampling strategy presented here was designed to generate a representative sample of the Iraqi population while reducing the potential for bias and considering the context specific challenges of the study setting. This sampling strategy, or variations on it, are adaptable and should be considered and tested in other conflict settings.
2012-01-01
Background Mortality estimates can measure and monitor the impacts of conflict on a population, guide humanitarian efforts, and help to better understand the public health impacts of conflict. Vital statistics registration and surveillance systems are rarely functional in conflict settings, posing a challenge of estimating mortality using retrospective population-based surveys. Results We present a two-stage cluster sampling method for application in population-based mortality surveys. The sampling method utilizes gridded population data and a geographic information system (GIS) to select clusters in the first sampling stage and Google Earth TM imagery and sampling grids to select households in the second sampling stage. The sampling method is implemented in a household mortality study in Iraq in 2011. Factors affecting feasibility and methodological quality are described. Conclusion Sampling is a challenge in retrospective population-based mortality studies and alternatives that improve on the conventional approaches are needed. The sampling strategy presented here was designed to generate a representative sample of the Iraqi population while reducing the potential for bias and considering the context specific challenges of the study setting. This sampling strategy, or variations on it, are adaptable and should be considered and tested in other conflict settings. PMID:22540266
Hu, Zonghui; Qin, Jing
2018-05-20
Many observational studies adopt what we call retrospective convenience sampling (RCS). With the sample size in each arm prespecified, RCS randomly selects subjects from the treatment-inclined subpopulation into the treatment arm and those from the control-inclined into the control arm. Samples in each arm are representative of the respective subpopulation, but the proportion of the 2 subpopulations is usually not preserved in the sample data. We show in this work that, under RCS, existing causal effect estimators actually estimate the treatment effect over the sample population instead of the underlying study population. We investigate how to correct existing methods for consistent estimation of the treatment effect over the underlying population. Although RCS is adopted in medical studies for ethical and cost-effective purposes, it also has a big advantage for statistical inference: When the tendency to receive treatment is low in a study population, treatment effect estimators under RCS, with proper correction, are more efficient than their parallels under random sampling. These properties are investigated both theoretically and through numerical demonstration. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.
[The research protocol III. Study population].
Arias-Gómez, Jesús; Villasís-Keever, Miguel Ángel; Miranda-Novales, María Guadalupe
2016-01-01
The study population is defined as a set of cases, determined, limited, and accessible, that will constitute the subjects for the selection of the sample, and must fulfill several characteristics and distinct criteria. The objectives of this manuscript are focused on specifying each one of the elements required to make the selection of the participants of a research project, during the elaboration of the protocol, including the concepts of study population, sample, selection criteria and sampling methods. After delineating the study population, the researcher must specify the criteria that each participant has to comply. The criteria that include the specific characteristics are denominated selection or eligibility criteria. These criteria are inclusion, exclusion and elimination, and will delineate the eligible population. The sampling methods are divided in two large groups: 1) probabilistic or random sampling and 2) non-probabilistic sampling. The difference lies in the employment of statistical methods to select the subjects. In every research, it is necessary to establish at the beginning the specific number of participants to be included to achieve the objectives of the study. This number is the sample size, and can be calculated or estimated with mathematical formulas and statistic software.
Munchel, Sarah; Hoang, Yen; Zhao, Yue; Cottrell, Joseph; Klotzle, Brandy; Godwin, Andrew K; Koestler, Devin; Beyerlein, Peter; Fan, Jian-Bing; Bibikova, Marina; Chien, Jeremy
2015-09-22
Current genomic studies are limited by the poor availability of fresh-frozen tissue samples. Although formalin-fixed diagnostic samples are in abundance, they are seldom used in current genomic studies because of the concern of formalin-fixation artifacts. Better characterization of these artifacts will allow the use of archived clinical specimens in translational and clinical research studies. To provide a systematic analysis of formalin-fixation artifacts on Illumina sequencing, we generated 26 DNA sequencing data sets from 13 pairs of matched formalin-fixed paraffin-embedded (FFPE) and fresh-frozen (FF) tissue samples. The results indicate high rate of concordant calls between matched FF/FFPE pairs at reference and variant positions in three commonly used sequencing approaches (whole genome, whole exome, and targeted exon sequencing). Global mismatch rates and C · G > T · A substitutions were comparable between matched FF/FFPE samples, and discordant rates were low (<0.26%) in all samples. Finally, low-pass whole genome sequencing produces similar pattern of copy number alterations between FF/FFPE pairs. The results from our studies suggest the potential use of diagnostic FFPE samples for cancer genomic studies to characterize and catalog variations in cancer genomes.
Tang, Hongmao; Beg, Khaliq R.; Al-Otaiba, Yousef
2006-01-01
Kuwait experiences desert climatic weather. Due to the extreme hot and dry conditions in this country, some analytical phenomena have been discovered. Therefore, a systematic study of sampling and analyzing volatile organic compounds in air by using GC-MS with a cryogenic trap is reported in this paper. This study included comparisons of using different sample containers such as Tedlar bags and SUMMA canisters, and different cryogenic freezing-out air volumes in the trap. Calibration curves for different compounds and improvement of replicated analysis results were also reported here. The study found that using different sample containers produced different results. Analysis of ambient air samples collected in Tedlar bags obtained several volatile organic compounds with large concentrations compared to using SUMMA canisters. Therefore, to choose a sample container properly is a key element for successfully completing a project. Because GC-MS with a cryogenic trap often generates replicated results with poor agreement, an internal standard added to gas standards and air samples by using a gas syringe was tested. The study results proved that it helped to improve the replicated results. PMID:16699723
Tang, Hongmao; Beg, Khaliq R; Al-Otaiba, Yousef
2006-05-12
Kuwait experiences desert climatic weather. Due to the extreme hot and dry conditions in this country, some analytical phenomena have been discovered. Therefore, a systematic study of sampling and analyzing volatile organic compounds in air by using GC-MS with a cryogenic trap is reported in this paper. This study included comparisons of using different sample containers such as Tedlar bags and SUMMA canisters, and different cryogenic freezing-out air volumes in the trap. Calibration curves for different compounds and improvement of replicated analysis results were also reported here. The study found that using different sample containers produced different results. Analysis of ambient air samples collected in Tedlar bags obtained several volatile organic compounds with large concentrations compared to using SUMMA canisters. Therefore, to choose a sample container properly is a key element for successfully completing a project. Because GC-MS with a cryogenic trap often generates replicated results with poor agreement, an internal standard added to gas standards and air samples by using a gas syringe was tested. The study results proved that it helped to improve the replicated results.
Recruiting and enrolling pregnant adolescents for research.
Kaiser, Margaret M; Hays, Bevely J
2006-01-01
Difficulty obtaining a sample is not justification for failure to study a hard-to-enroll population, particularly a vulnerable population such as pregnant adolescents. Recruitment of a representative, adequate sample of pregnant adolescents for a recent instrument development study provided multiple challenges. Although carefully developed, the sampling plan required several modifications to achieve the sample (n=145). Those challenges and the ensuing modifications to the sampling plan are discussed in relation to (a) access/institutional concerns, (b) the human subject's protection considerations, and (c) developmental/personal concerns of the pregnant adolescents. Recommendations for sampling strategies for future research are offered.
Development study of the X-ray scattering properties of a group of optically polished flat samples
NASA Technical Reports Server (NTRS)
Froechtenigt, J. F.
1973-01-01
A group of twelve optically polished flat samples were used to study the scattering of X-rays. The X-ray beam reflected from the twelve optical flat samples was analyzed by means of a long vacuum system of special design for these tests. The scattering measurements were made at 8.34A and 0.92 deg angle of incidence. The results for ten of the samples are comparable, the two exceptions being the fire polished samples.
Corn blight review: Sampling model and ground data measurements program
NASA Technical Reports Server (NTRS)
Allen, R. D.
1972-01-01
The sampling plan involved the selection of the study area, determination of the flightline and segment sample design within the study area, and determination of a field sample design. Initial interview survey data consisting of crop species acreage and land use were collected. On all corn fields, additional information such as seed type, row direction, population, planting date, ect. were also collected. From this information, sample corn fields were selected to be observed through the growing season on a biweekly basis by county extension personnel.
Lan, Jiayi; Núñez Galindo, Antonio; Doecke, James; Fowler, Christopher; Martins, Ralph N; Rainey-Smith, Stephanie R; Cominetti, Ornella; Dayon, Loïc
2018-04-06
Over the last two decades, EDTA-plasma has been used as the preferred sample matrix for human blood proteomic profiling. Serum has also been employed widely. Only a few studies have assessed the difference and relevance of the proteome profiles obtained from plasma samples, such as EDTA-plasma or lithium-heparin-plasma, and serum. A more complete evaluation of the use of EDTA-plasma, heparin-plasma, and serum would greatly expand the comprehensiveness of shotgun proteomics of blood samples. In this study, we evaluated the use of heparin-plasma with respect to EDTA-plasma and serum to profile blood proteomes using a scalable automated proteomic pipeline (ASAP 2 ). The use of plasma and serum for mass-spectrometry-based shotgun proteomics was first tested with commercial pooled samples. The proteome coverage consistency and the quantitative performance were compared. Furthermore, protein measurements in EDTA-plasma and heparin-plasma samples were comparatively studied using matched sample pairs from 20 individuals from the Australian Imaging, Biomarkers and Lifestyle (AIBL) Study. We identified 442 proteins in common between EDTA-plasma and heparin-plasma samples. Overall agreement of the relative protein quantification between the sample pairs demonstrated that shotgun proteomics using workflows such as the ASAP 2 is suitable in analyzing heparin-plasma and that such sample type may be considered in large-scale clinical research studies. Moreover, the partial proteome coverage overlaps (e.g., ∼70%) showed that measures from heparin-plasma could be complementary to those obtained from EDTA-plasma.
Variability of indoor fungal microbiome of green and non-green low-income homes in Cincinnati, Ohio.
Coombs, Kanistha; Taft, Diana; Ward, Doyle V; Green, Brett J; Chew, Ginger L; Shamsaei, Behrouz; Meller, Jaroslaw; Indugula, Reshmi; Reponen, Tiina
2018-01-01
"Green" housing is designed to use low-impact materials, increase energy efficiency and improve occupant health. However, little is known about the indoor mycobiome of green homes. The current study is a subset of a multicenter study that aims to investigate the indoor environment of green homes and the respiratory health of asthmatic children. In the current study, the mycobiome in air, bed dust and floor dust was compared between green (study site) and non-green (control site), low-income homes in Cincinnati, Ohio. The samples were collected at baseline (within four months following renovation), and 12months after the baseline at the study site. Parallel sample collection was conducted in non-green control homes. Air samples were collected by PM2.5 samplers over 5-days. Bed and floor dust samples were vacuumed after the air sampling was completed. The DNA sample extracts were analyzed using ITS amplicon sequencing. Analysis indicated that there was no clear trend in the fungal communities between green and non-green homes. Instead, fungal community differences were greatest between sample types - air, bed, and floor. Microbial communities also changed substantially between sampling intervals in both green and non-green homes for all sample types, potentially indicating that there was very little stability in the mycobiomes. Research gaps remain regarding how indoor mycobiome fluctuates over time. Longer follow-up periods might elucidate the effect of green renovation on microbial load in buildings. Copyright © 2017 Elsevier B.V. All rights reserved.
Michie, Marsha; Henderson, Gail; Garrett, Joanne; Corbie-Smith, Giselle
2012-01-01
Human genome research depends upon participants who donate genetic samples, but few studies have explored in depth the motivations of genetic research donors. This mixed methods study examines telephone interviews with 752 sample donors in a U.S. genetic epidemiology study investigating colorectal cancer. Quantitative and qualitative results indicate that most participants wanted to help society, and that many also wanted information about their own health, even though such information was not promised. Qualitative analysis reveals that donors believed their samples contributed to a scientific “common good”; imagined samples as information rather than tissues; and often blurred distinctions between research and diagnostic testing of samples. Differences between African American and White perspectives were distinct from educational and other possible explanatory factors. PMID:21680977
In situ study of live specimens in an environmental scanning electron microscope.
Tihlaříková, Eva; Neděla, Vilém; Shiojiri, Makoto
2013-08-01
In this paper we introduce new methodology for the observation of living biological samples in an environmental scanning electron microscope (ESEM). The methodology is based on an unconventional initiation procedure for ESEM chamber pumping, free from purge-flood cycles, and on the ability to control thermodynamic processes close to the sample. The gradual and gentle change of the working environment from air to water vapor enables the study of not only living samples in dynamic in situ experiments and their manifestation of life (sample walking) but also its experimentally stimulated physiological reactions. Moreover, Monte Carlo simulations of primary electron beam energy losses in a water layer on the sample surface were studied; consequently, the influence of the water thickness on radiation, temperature, or chemical damage of the sample was considered.
Time-of-travel data for Nebraska streams, 1968 to 1977
Petri, L.R.
1984-01-01
This report documents the results of 10 time-of-travel studies, using ' dye-tracer ' methods, conducted on five streams in Nebraska during the period 1968 to 1977. Streams involved in the studies were the North Platte, North Loup, Elkhorn, and Big Blue Rivers and Salt Creek. Rhodamine WT dye in a 20 percent solution was used as the tracer for all 10 time-of-travel studies. Water samples were collected at several points below each injection site. Concentrations of dye in the samples were measured by determining fluorescence of the sample and comparing that value to fluorescence-concentration curves. Stream discharges were measured before and during each study. Results of each time-by-travel study are shown on two tables and on graph. The first table shows water discharge at injection and sampling sites, distance between sites, and time and rate of travel of the dye between sites. The second table provides descriptions of study sites, amounts of dye injected in the streams, actual sampling times, and actual concentrations of dye detected. The graphs for each time-of-travel study provide indications of changing travel rates between sampling sites, information on length of dye clouds, and times for dye passage past given points. (USGS)
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR PESTICIDE METABOLITES IN BLANK SAMPLES
The Pesticide Metabolites in Blank Samples data set contains the analytical results of measurements of up to 4 pesticide metabolites in 3 blank samples from 3 households. Measurements were made in blank samples of urine. Blank samples were used to assess the potential for sampl...
Dashti, Narjes; Ali, Nedaa; Salamah, Samar; Khanafer, Majida; Al-Shamy, Ghada; Al-Awadhi, Husain; Radwan, Samir S
2018-04-15
To analyze microbial communities in environmental samples, this study combined Denaturing Gradient Gel Electrophoresis of amplified 16S rRNA-genes in total genomic DNA extracts from those samples with gene sequencing. The environmental samples studied were oily seawater and soil samples, that had been bioaugmented with natural materials rich in hydrocarbonoclastic bacteria. This molecular approach revealed much more diverse bacterial taxa than the culture-dependent method we had used in an earlier study for the analysis of the same samples. The study described the dynamics of bacterial communities during bioremediation. The main limitation associated with this molecular approach, namely of not distinguishing hydrocarbonoclastic taxa from others, was overcome by consulting the literature for the hydrocarbonoclastic potential of taxa related to those identified in this study. By doing so, it was concluded that the hydrocarbonoclastic bacterial taxa were much more diverse than those captured by the culture-dependent approach. The molecular analysis also revealed the frequent occurrence of nifH-genes in the total genomic DNA extracts of all the studied environmental samples, which reflects a nitrogen-fixation potential. Nitrogen fertilization is long known to enhance microbial oil-bioremediation. The study revealed that bioaugmentation using plant rhizospheres or soil with long history of oil-pollution was more effective in oil-removal in the desert soil than in seawater microcosms. © 2018 The Authors. MicrobiologyOpen published by John Wiley & Sons Ltd.
Abu Aboud, Omran A; Adaska, John M; Williams, Deniece R; Rossitto, Paul V; Champagne, John D; Lehenbauer, Terry W; Atwill, Robert; Li, Xunde; Aly, Sharif S
2016-01-01
The primary objective of this cross-sectional study was to estimate the crude, seasonal and cull-reason stratified prevalence of Salmonella fecal shedding in cull dairy cattle on seven California dairies. A secondary objective was to estimate and compare the relative sensitivity (Se) and specificity (Sp) for pools of 5 and 10 enriched broth cultures of fecal samples for Salmonella sp. detection. Seven dairy farms located in the San Joaquin Valley of California were identified and enrolled in the study as a convenience sample. Cull cows were identified for fecal sampling once during each season between 2014 and 2015, specifically during spring, summer, fall, and winter, and 10 cows were randomly selected for fecal sampling at the day of their sale. In addition, study personnel completed a survey based on responses of the herd manager to questions related to the previous four month's herd management. Fecal samples were frozen until testing for Salmonella. After overnight enrichment in liquid broth, pools of enrichment broth (EBP) were created for 5 and 10 samples. All individual and pooled broths were cultured on selective media with putative Salmonella colonies confirmed by biochemical testing before being serogrouped and serotyped. A total of 249 cull cows were enrolled into the study and their fecal samples tested for Salmonella. The survey-weighted period prevalence of fecal shedding of all Salmonella sp. in the cull cow samples across all study herds and the entire study period was 3.42% (N = 249; SE 1.07). The within herd prevalence of Salmonella shed in feces did not differ over the four study seasons (P = 0.074). The Se of culture of EBP of five samples was 62.5% (SE = 17.12), which was not statistically different from the Se of culture of EBP of 10 (37.5%, SE = 17.12, P = 0.48). The Sp of culture of EBP of five samples was 95.24% (SE = 3.29) and for pools of 10 samples was 100.00% (SE = 0). There was no statistical difference between the culture relative specificities of EBP of 5 and 10 (P > 0.99). Our study showed a numerically higher prevalence of Salmonella shedding in the summer, although the results were not significant, most likely due to a lack of power from the small sample size. A higher prevalence in summer months may be related to heat stress. To detect Salmonella, investigators may expect a 62.5% sensitivity for culture of EBP of five, relative to individual fecal sample enrichment and culture. In contrast, culture of EBP of 10 samples resulted in a numerically lower Se. Culture of EBP of size 5 or 10 samples, given similar prevalence and limit of detection, can be expected to yield specificities of 95 and 100%, respectively.
Abu Aboud, Omran A.; Adaska, John M.; Williams, Deniece R.; Rossitto, Paul V.; Champagne, John D.; Lehenbauer, Terry W.; Atwill, Robert; Li, Xunde
2016-01-01
Background The primary objective of this cross-sectional study was to estimate the crude, seasonal and cull-reason stratified prevalence of Salmonella fecal shedding in cull dairy cattle on seven California dairies. A secondary objective was to estimate and compare the relative sensitivity (Se) and specificity (Sp) for pools of 5 and 10 enriched broth cultures of fecal samples for Salmonella sp. detection. Methods Seven dairy farms located in the San Joaquin Valley of California were identified and enrolled in the study as a convenience sample. Cull cows were identified for fecal sampling once during each season between 2014 and 2015, specifically during spring, summer, fall, and winter, and 10 cows were randomly selected for fecal sampling at the day of their sale. In addition, study personnel completed a survey based on responses of the herd manager to questions related to the previous four month’s herd management. Fecal samples were frozen until testing for Salmonella. After overnight enrichment in liquid broth, pools of enrichment broth (EBP) were created for 5 and 10 samples. All individual and pooled broths were cultured on selective media with putative Salmonella colonies confirmed by biochemical testing before being serogrouped and serotyped. Results A total of 249 cull cows were enrolled into the study and their fecal samples tested for Salmonella. The survey-weighted period prevalence of fecal shedding of all Salmonella sp. in the cull cow samples across all study herds and the entire study period was 3.42% (N = 249; SE 1.07). The within herd prevalence of Salmonella shed in feces did not differ over the four study seasons (P = 0.074). The Se of culture of EBP of five samples was 62.5% (SE = 17.12), which was not statistically different from the Se of culture of EBP of 10 (37.5%, SE = 17.12, P = 0.48). The Sp of culture of EBP of five samples was 95.24% (SE = 3.29) and for pools of 10 samples was 100.00% (SE = 0). There was no statistical difference between the culture relative specificities of EBP of 5 and 10 (P > 0.99). Discussion Our study showed a numerically higher prevalence of Salmonella shedding in the summer, although the results were not significant, most likely due to a lack of power from the small sample size. A higher prevalence in summer months may be related to heat stress. To detect Salmonella, investigators may expect a 62.5% sensitivity for culture of EBP of five, relative to individual fecal sample enrichment and culture. In contrast, culture of EBP of 10 samples resulted in a numerically lower Se. Culture of EBP of size 5 or 10 samples, given similar prevalence and limit of detection, can be expected to yield specificities of 95 and 100%, respectively. PMID:27635350
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2001-01-01
A laboratory for analysis of low-ionic strength water has been developed at the U.S. Geological Survey (USGS) office in Troy, N.Y., to analyze samples collected by USGS projects in the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures developed to ensure proper sample collection, processing, and analysis. The quality-assurance/quality-control data are stored in the laboratory's SAS data-management system, which provides efficient review, compilation, and plotting of quality-assurance/quality-control data. This report presents and discusses samples analyzed from July 1993 through June 1995. Quality-control results for 18 analytical procedures were evaluated for bias and precision. Control charts show that data from seven of the analytical procedures were biased throughout the analysis period for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, dissolved inorganic carbon, dissolved organic carbon (soil expulsions), chloride, magnesium, nitrate (colorimetric method), and pH. Three of the analytical procedures were occasionally biased but were within control limits; they were: calcium (high for high-concentration samples for May 1995), dissolved organic carbon (high for highconcentration samples from January through September 1994), and fluoride (high in samples for April and June 1994). No quality-control sample has been developed for the organic monomeric aluminum procedure. Results from the filter-blank and analytical-blank analyses indicate that all analytical procedures in which blanks were run were within control limits, although values for a few blanks were outside the control limits. Blanks were not analyzed for acid-neutralizing capacity, dissolved inorganic carbon, fluoride, nitrate (colorimetric method), or pH. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in 14 of the 18 procedures. Data-quality objectives were met by more than 90 percent of the samples analyzed in all procedures except total monomeric aluminum (85 percent of samples met objectives), total aluminum (70 percent of samples met objectives), and dissolved organic carbon (85 percent of samples met objectives). Triplicate samples were not analyzed for ammonium, fluoride, dissolved inorganic carbon, or nitrate (colorimetric method). Results of the USGS interlaboratory Standard Reference Sample Program indicated high data quality with a median result of 3.6 of a possible 4.0. Environment Canada's LRTAP interlaboratory study results indicated that more than 85 percent of the samples met data-quality objectives in 6 of the 12 analyses; exceptions were calcium, dissolved organic carbon, chloride, pH, potassium, and sodium. Data-quality objectives were not met for calcium samples in one LRTAP study, but 94 percent of samples analyzed were within control limits for the remaining studies. Data-quality objectives were not met by 35 percent of samples analyzed for dissolved organic carbon, but 94 percent of sample values were within 20 percent of the most probable value. Data-quality objectives were not met for 30 percent of samples analyzed for chloride, but 90 percent of sample values were within 20 percent of the most probable value. Measurements of samples with a pH above 6.0 were biased high in 54 percent of the samples, although 85 percent of the samples met data-quality objectives for pH measurements below 6.0. Data-quality objectives for potassium and sodium were not met in one study (only 33 percent of the samples analyzed met the objectives), although 85 percent of the sample values were within control limits for the other studies. Measured sodium values were above the upper control limit in all studies. Results from blind reference-sample analyses indicated that data
Application of work sampling technique to analyze logging operations.
Edwin S. Miyata; Helmuth M. Steinhilb; Sharon A. Winsauer
1981-01-01
Discusses the advantages and disadvantages of various time study methods for determining efficiency and productivity in logging. The work sampling method is compared with the continuous time-study method. Gives the feasibility, capability, and limitation of the work sampling method.
Foo, Lee Kien; McGree, James; Duffull, Stephen
2012-01-01
Optimal design methods have been proposed to determine the best sampling times when sparse blood sampling is required in clinical pharmacokinetic studies. However, the optimal blood sampling time points may not be feasible in clinical practice. Sampling windows, a time interval for blood sample collection, have been proposed to provide flexibility in blood sampling times while preserving efficient parameter estimation. Because of the complexity of the population pharmacokinetic models, which are generally nonlinear mixed effects models, there is no analytical solution available to determine sampling windows. We propose a method for determination of sampling windows based on MCMC sampling techniques. The proposed method attains a stationary distribution rapidly and provides time-sensitive windows around the optimal design points. The proposed method is applicable to determine sampling windows for any nonlinear mixed effects model although our work focuses on an application to population pharmacokinetic models. Copyright © 2012 John Wiley & Sons, Ltd.
Hottes, Travis Salway; Bogaert, Laura; Rhodes, Anne E; Brennan, David J; Gesink, Dionne
2016-05-01
Previous reviews have demonstrated a higher risk of suicide attempts for lesbian, gay, and bisexual (LGB) persons (sexual minorities), compared with heterosexual groups, but these were restricted to general population studies, thereby excluding individuals sampled through LGB community venues. Each sampling strategy, however, has particular methodological strengths and limitations. For instance, general population probability studies have defined sampling frames but are prone to information bias associated with underreporting of LGB identities. By contrast, LGB community surveys may support disclosure of sexuality but overrepresent individuals with strong LGB community attachment. To reassess the burden of suicide-related behavior among LGB adults, directly comparing estimates derived from population- versus LGB community-based samples. In 2014, we searched MEDLINE, EMBASE, PsycInfo, CINAHL, and Scopus databases for articles addressing suicide-related behavior (ideation, attempts) among sexual minorities. We selected quantitative studies of sexual minority adults conducted in nonclinical settings in the United States, Canada, Europe, Australia, and New Zealand. Random effects meta-analysis and meta-regression assessed for a difference in prevalence of suicide-related behavior by sample type, adjusted for study or sample-level variables, including context (year, country), methods (medium, response rate), and subgroup characteristics (age, gender, sexual minority construct). We examined residual heterogeneity by using τ(2). We pooled 30 cross-sectional studies, including 21,201 sexual minority adults, generating the following lifetime prevalence estimates of suicide attempts: 4% (95% confidence interval [CI] = 3%, 5%) for heterosexual respondents to population surveys, 11% (95% CI = 8%, 15%) for LGB respondents to population surveys, and 20% (95% CI = 18%, 22%) for LGB respondents to community surveys (Figure 1). The difference in LGB estimates by sample type persisted after we accounted for covariates with meta-regression. Sample type explained 33% of the between-study variability. Regardless of sample type examined, sexual minorities had a higher lifetime prevalence of suicide attempts than heterosexual persons; however, the magnitude of this disparity was contingent upon sample type. Community-based surveys of LGB people suggest that 20% of sexual minority adults have attempted suicide. Accurate estimates of sexual minority health disparities are necessary for public health monitoring and research. Most data describing these disparities are derived from 2 sample types, which yield different estimates of the lifetime prevalence of suicide attempts. Additional studies should explore the differential effects of selection and information biases on the 2 predominant sampling approaches used to understand sexual minority health.
Observational studies of patients in the emergency department: a comparison of 4 sampling methods.
Valley, Morgan A; Heard, Kennon J; Ginde, Adit A; Lezotte, Dennis C; Lowenstein, Steven R
2012-08-01
We evaluate the ability of 4 sampling methods to generate representative samples of the emergency department (ED) population. We analyzed the electronic records of 21,662 consecutive patient visits at an urban, academic ED. From this population, we simulated different models of study recruitment in the ED by using 2 sample sizes (n=200 and n=400) and 4 sampling methods: true random, random 4-hour time blocks by exact sample size, random 4-hour time blocks by a predetermined number of blocks, and convenience or "business hours." For each method and sample size, we obtained 1,000 samples from the population. Using χ(2) tests, we measured the number of statistically significant differences between the sample and the population for 8 variables (age, sex, race/ethnicity, language, triage acuity, arrival mode, disposition, and payer source). Then, for each variable, method, and sample size, we compared the proportion of the 1,000 samples that differed from the overall ED population to the expected proportion (5%). Only the true random samples represented the population with respect to sex, race/ethnicity, triage acuity, mode of arrival, language, and payer source in at least 95% of the samples. Patient samples obtained using random 4-hour time blocks and business hours sampling systematically differed from the overall ED patient population for several important demographic and clinical variables. However, the magnitude of these differences was not large. Common sampling strategies selected for ED-based studies may affect parameter estimates for several representative population variables. However, the potential for bias for these variables appears small. Copyright © 2012. Published by Mosby, Inc.
Gierke, Lioba; Binder, Nadine; Heckmann, Mark; Odağ, Özen; Leiser, Anne; Kedzior, Karina Karolina
2018-01-01
Intercultural competence (IC) is an important skill to be gained from higher education. However, it remains unclear what IC means to students and what factors might influence their definitions of IC. The aim of the current study was to qualitatively assess how students at one higher education institution in the USA define IC and to quantitatively test for relationships among IC components and various demographic characteristics, including intercultural experience and study context. A further aim was to descriptively compare the IC definitions from the US sample with the definitions obtained from another sample of university students in Germany. A purposive sample of n = 93 undergraduate, second semester students at Dickinson College, USA, participated in the study by completing an online questionnaire. The qualitative data were content-analyzed to define the dimensions of IC. The quantitative data were cluster-analyzed to assess the multivariate relationships among the IC components and the demographic characteristics of the sample. The most important dimensions of IC were Knowledge, External Outcomes (interaction, communication), and Attitudes (respect, tolerance) according to the US sample. The most frequently chosen dimensions of IC differed between both samples: Knowledge was chosen by the sample in the USA while External Outcomes was chosen by the sample in Germany. Relative to the US sample, significantly more students chose Attitudes, External Outcomes, and Intrapersonal Skills in the sample in Germany. The relationships among IC components and demographic characteristics were only weak in the US sample. A person with IC was rated as Open-minded and Respectful by students who lived predominantly in the USA or Tolerant and Curious by those who lived outside the USA for at least six months. The current results suggest that students residing in two countries (USA or Germany) define IC using similar dimensions. However, IC definitions may depend on the intercultural experience and the current global discourse. Longitudinal studies with representative samples are required to assess how IC definitions change over time.
NASA Astrophysics Data System (ADS)
Keizer, J. J.; Martins, M. A. S.; Prats, S. A.; Santos, L. F.; Vieira, D. C. S.; Nogueira, R.; Bilro, L.
2015-09-01
This study is the first comprehensive testing of a novel plastic optical fibre turbidity sensor with runoff samples collected in the field and, more specifically, with a total of 158 streamflow samples and 925 overland flow samples from a recently burnt forest area in north-central Portugal, collected mainly during the first year after the wildfire, as well as with 56 overland flow samples from a nearby long-unburnt study site. Sediment concentrations differed less between overland flow and streamflow samples than between study sites and, at one study site, between plots with and without effective erosion mitigation treatments. Maximum concentrations ranged from 0.91 to 8.19 g L-1 for the micro-plot overland flow samples from the six burnt sites, from 1.74 to 8.99 g L-1 for the slope-scale overland flow samples from these same sites, and amounted to 4.55 g L-1 for the streamflow samples. Power functions provided (reasonably) good fits to the - expected - relationships of increasing normalized light loss with increasing sediment concentrations for the different sample types from individual study sites. The corresponding adjusted R2 values ranged from 0.64 to 0.81 in the case of the micro-plot samples from the six burnt sites, from 0.72 to 0.89 in the case of the slope-scale samples from these same sites, and was 0.85 in the case of the streamflow samples. While the overall performance of the sensor was thus rather satisfactory, the results pointed to the need for scale of site-specific calibrations to maximize the reliability of the predictions of sediment concentration by the POF (plastic optical fibre) sensor. This especially applied to the cases in which sediment concentrations were comparatively low, for example following mulching with forest residues.
Wickremsinhe, Enaksha R; Perkins, Everett J
2015-03-01
Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 μL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal-often to a single collection per mouse-thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 μL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study.
Wickremsinhe, Enaksha R; Perkins, Everett J
2015-01-01
Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 µL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal—often to a single collection per mouse—thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 µL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study. PMID:25836959
A survey of current practices for sampling and examination of the nervous system in rodents and non-rodents for general and neurotoxicity (NT) studies was conducted by the Nervous System Sampling Subcommittee of the STP. For general toxicity studies most of those surveyed (>63%) ...
Lorber, M.; Johnson, Kevin; Kross, B.; Pinsky, P.; Burmeister, L.; Thurman, M.; Wilkins, A.; Hallberg, G.
1997-01-01
In 1988, the Iowa Department of Natural Resources, along with the University of Iowa conducted the Statewide Rural Well Water Survey, commonly known as SWRL. A total of 686 private rural drinking water wells was selected by use of a probability sample and tested for pesticides and nitrates. Sixty-eight of these wells, the '10% repeat' wells, were additionally sampled in October, 1990 and June, 1991. Starting in November, 1991, the University of Iowa, with sponsorship from the United States Environmental Protection Agency, revisited these wells to begin a study of the temporal variability of atrazine and nitrates in wells. Other wells, which had originally tested positive for atrazine in SWRL but were not in the 10% repeat population, were added to the study population. Temporal sampling for a year-long period began in February of 1992 and concluded in January of 1993. All wells were sampled monthly, one subset was sampled weekly, and a second subset was sampled for 14-day consecutive periods. Two unique aspects of this study were the use of an immunoassay technique to screen for triazines before gas chromatography/mass spectrometry (GC/MS) analysis and quantification of atrazine, and the use of well owners to sample the wells. A total of 1771 samples from 83 wells are in the final data base for this study. This paper reviews the study design, the analytical methodologies, and development of the data base. A companion paper discusses the analysis of the data from this survey.
The generalization ability of online SVM classification based on Markov sampling.
Xu, Jie; Yan Tang, Yuan; Zou, Bin; Xu, Zongben; Li, Luoqing; Lu, Yang
2015-03-01
In this paper, we consider online support vector machine (SVM) classification learning algorithms with uniformly ergodic Markov chain (u.e.M.c.) samples. We establish the bound on the misclassification error of an online SVM classification algorithm with u.e.M.c. samples based on reproducing kernel Hilbert spaces and obtain a satisfactory convergence rate. We also introduce a novel online SVM classification algorithm based on Markov sampling, and present the numerical studies on the learning ability of online SVM classification based on Markov sampling for benchmark repository. The numerical studies show that the learning performance of the online SVM classification algorithm based on Markov sampling is better than that of classical online SVM classification based on random sampling as the size of training samples is larger.
Schultze, A; Akmatov, M K; Andrzejak, M; Karras, N; Kemmling, Y; Maulhardt, A; Wieghold, S; Ahrens, W; Günther, K; Schlenz, H; Krause, G; Pessler, F
2014-11-01
For certain laboratory investigations it is necessary to obtain native stool samples and process them within a narrow time window at the point of contact or a nearby laboratory. However, it is not known whether it is feasible to obtain stool samples from asymptomatic individuals during an appointment in a study center (SC). We therefore compared participants' preference, feasibility and acceptance of stool sample collection during the appointment at the study center (on-site sampling) to collection at home after the appointment. The study was conducted at two sites in Northern Germany (Bremen, n = 156; Hannover, n = 147) during the Pretest 2 phase of the German National Cohort (GNC), drawing upon a randomly selected population supplemented by a small convenience sample. In the study center, the participants were given the choice to provide a stool sample during the appointment or to collect a sample later at home and return it by mail. In all, 303 of the 351 participants (86 %) of Pretest 2 at these sites participated in this feasibility study. Only 7.9 % (24/303) of the participants chose on-site collection, whereas 92 % (279/303) chose at-home collection. There were significant differences between the two study sites in that 14 % (21/147) of participants in Hannover and 2 % (3/156) of participants in Bremen chose on-site collection. Compliance was high in both groups, as 100 % (24/24) and 98 % (272/279) of participants in the on-site and at-home groups, respectively, provided complete samples. Both methods were highly accepted, as 92 % of the participants in each group (22/24 and 227/248) stated that stool collection at the respective site was acceptable. When given a choice, most participants in this population-based study preferred home collection of stool samples to collection in the study center. Thus, native stool samples for immediate processing in the study center may potentially be obtained only from a subpopulation of participants, which may lead to selection bias. Home collection, on the other hand, proved to be a highly feasible method for studies that do not require freshly collected native stool.
Santamaría, Eva; Estévez, Javier Alejandro; Riba, Jordi; Izquierdo, Iñaki; Valle, Marta
2017-01-01
To optimise a pharmacokinetic (PK) study design of rupatadine for 2-5 year olds by using a population PK model developed with data from a study in 6-11 year olds. The design optimisation was driven by the need to avoid children's discomfort in the study. PK data from 6-11 year olds with allergic rhinitis available from a previous study were used to construct a population PK model which we used in simulations to assess the dose to administer in a study in 2-5 year olds. In addition, an optimal design approach was used to determine the most appropriate number of sampling groups, sampling days, total samples and sampling times. A two-compartmental model with first-order absorption and elimination, with clearance dependent on weight adequately described the PK of rupatadine for 6-11 year olds. The dose selected for a trial in 2-5 year olds was 2.5 mg, as it provided a Cmax below the 3 ng/ml threshold. The optimal study design consisted of four groups of children (10 children each), a maximum sampling window of 2 hours in two clinic visits for drawing three samples on day 14 and one on day 28 coinciding with the final examination of the study. A PK study design was optimised in order to prioritise avoidance of discomfort for enrolled 2-5 year olds by taking only four blood samples from each child and minimising the length of hospital stays.
The purpose of this SOP is to establish a uniform procedure for the collection of indoor floor dust samples in the field. This procedure was followed to ensure consistent data retrieval of dust samples during the Arizona NHEXAS project and the Border study. Keywords: field; vacu...
A Comparison of Two Sampling Strategies to Assess Discomycete Diversity in Wet Tropical Forests
SHARON A. CANTRELL
2004-01-01
Most of the fungal diversity studies that have used a systematic collecting scheme have not included the discomycetes, so optimal sampling methods are not available for this group. In this study, I tested two sampling methods at each sites in the Caribbean National Forest, Puerto Rico and Ebano Verde Reserve, Dominican Republic. For a plot-based sampling method, 10 Ã...
This abstract is included for completeness of documentation, but this SOP was not used in the study.
The purpose of this SOP is to describe the procedures for analyzing both Stage II and Stage III soil and vacuum-cleaner collected house dust samples, and Stage III air samples u...
Sample size calculations for case-control studies
This R package can be used to calculate the required samples size for unconditional multivariate analyses of unmatched case-control studies. The sample sizes are for a scalar exposure effect, such as binary, ordinal or continuous exposures. The sample sizes can also be computed for scalar interaction effects. The analyses account for the effects of potential confounder variables that are also included in the multivariate logistic model.
Insights from two industrial hygiene pilot e-cigarette passive vaping studies.
Maloney, John C; Thompson, Michael K; Oldham, Michael J; Stiff, Charles L; Lilly, Patrick D; Patskan, George J; Shafer, Kenneth H; Sarkar, Mohamadi A
2016-01-01
While several reports have been published using research methods of estimating exposure risk to e-cigarette vapors in nonusers, only two have directly measured indoor air concentrations from vaping using validated industrial hygiene sampling methodology. Our first study was designed to measure indoor air concentrations of nicotine, menthol, propylene glycol, glycerol, and total particulates during the use of multiple e-cigarettes in a well-characterized room over a period of time. Our second study was a repeat of the first study, and it also evaluated levels of formaldehyde. Measurements were collected using active sampling, near real-time and direct measurement techniques. Air sampling incorporated industrial hygiene sampling methodology using analytical methods established by the National Institute of Occupational Safety and Health and the Occupational Safety and Health Administration. Active samples were collected over a 12-hr period, for 4 days. Background measurements were taken in the same room the day before and the day after vaping. Panelists (n = 185 Study 1; n = 145 Study 2) used menthol and non-menthol MarkTen prototype e-cigarettes. Vaping sessions (six, 1-hr) included 3 prototypes, with total number of puffs ranging from 36-216 per session. Results of the active samples were below the limit of quantitation of the analytical methods. Near real-time data were below the lowest concentration on the established calibration curves. Data from this study indicate that the majority of chemical constituents sampled were below quantifiable levels. Formaldehyde was detected at consistent levels during all sampling periods. These two studies found that indoor vaping of MarkTen prototype e-cigarette does not produce chemical constituents at quantifiable levels or background levels using standard industrial hygiene collection techniques and analytical methods.
Bachmann-Harildstad, Gregor; Stenklev, Niels Christian; Myrvoll, Elin; Jablonski, Greg; Klingenberg, Olav
2011-01-01
The diagnosis of perilymphatic fluid (PLF) fistula is still challenging. Perilymphatic fluid fistula is one possible complication after stapedotomy or cochlear implant surgery. We have performed a prospective diagnostic pilot study to further investigate β-trace protein (β-TP) as a marker for PLF fistula. In this pilot study, we tested the sensitivity of the β-TP marker using a simple method for sample collection from the tympanic cavity. Prospective controlled diagnostic study. Two-center tertiary referral hospitals. A total of 35 adult patients undergoing ear surgery were included. Subjects were divided into 2 groups: 1) 19 patients undergoing stapedotomy were investigated for PLF fistula in samples obtained from the tympanic cavity and 2) 16 patients undergoing myringoplasty were investigated for PLF fistula in samples from the tympanic cavity. This group served as the control. Mean age +/- SD at surgery was 49.9 +/- 8.0 years in the study group and 39.69 +/- 15.47 years in the control group. β-Trace protein (prostaglandin D synthase) in tympanic cavity samples and serum samples was analyzed. The samples were collected by gradually filling the tympanic cavity with 100 to 200 μl sodium chloride and by immediately collecting a volume of 60 to 100 μl in a mucus specimen set container. The concentration of β-TP was quantified using laser nephelometry. The median β-TP in the study group was 0.8 mg/L (range, 0.05-4.5 mg/L). In the control group, the median β-TP value was 0.16 mg/L (range, 0.01-0.36 mg/L). Thirty-five percent of the values in the study group were below the highest value in the negative control group. The β-TP values of the tympanic cavity samples were significantly higher in the study group than in controls (p = 0.0001). The serum values were 0.55 +/- 0.18 and 0.53 +/- 0.11 mg/L, respectively. It may be feasible to test for PLF fistula using β-TP in samples from the tympanic cavity. Our results, however, suggest a relative low diagnostic sensitivity, given a cutoff that is set to obtain a high specificity when using a simple sample collection method. Furthermore, the test does not permit the distinction between PLF fistula and cerebrospinal fluid fistula. Further studies should focus on minimal dilution at sampling and on minimizing sample volumes.
Michaud, Jean-Philippe; Moreau, Gaétan
2013-07-01
Experimental protocols in forensic entomology successional field studies generally involve daily sampling of insects to document temporal changes in species composition on animal carcasses. One challenge with that method has been to adjust the sampling intensity to obtain the best representation of the community present without affecting the said community. To this date, little is known about how such investigator perturbations affect decomposition-related processes. Here, we investigated how different levels of daily sampling of fly eggs and fly larvae affected, over time, carcass decomposition rate and the carrion insect community. Results indicated that a daily sampling of <5% of the egg and larvae volumes present on a carcass, a sampling intensity believed to be consistent with current accepted practices in successional field studies, had little effect overall. Higher sampling intensities, however, slowed down carcass decomposition, affected the abundance of certain carrion insects, and caused an increase in the volume of eggs laid by dipterans. This study suggests that the carrion insect community not only has a limited resilience to recurrent perturbations but that a daily sampling intensity equal to or <5% of the egg and larvae volumes appears adequate to ensure that the system is representative of unsampled conditions. Hence we propose that this threshold be accepted as best practice in future forensic entomology successional field studies.
Sampling in ecology and evolution - bridging the gap between theory and practice
Albert, C.H.; Yoccoz, N.G.; Edwards, T.C.; Graham, C.H.; Zimmermann, N.E.; Thuiller, W.
2010-01-01
Sampling is a key issue for answering most ecological and evolutionary questions. The importance of developing a rigorous sampling design tailored to specific questions has already been discussed in the ecological and sampling literature and has provided useful tools and recommendations to sample and analyse ecological data. However, sampling issues are often difficult to overcome in ecological studies due to apparent inconsistencies between theory and practice, often leading to the implementation of simplified sampling designs that suffer from unknown biases. Moreover, we believe that classical sampling principles which are based on estimation of means and variances are insufficient to fully address many ecological questions that rely on estimating relationships between a response and a set of predictor variables over time and space. Our objective is thus to highlight the importance of selecting an appropriate sampling space and an appropriate sampling design. We also emphasize the importance of using prior knowledge of the study system to estimate models or complex parameters and thus better understand ecological patterns and processes generating these patterns. Using a semi-virtual simulation study as an illustration we reveal how the selection of the space (e.g. geographic, climatic), in which the sampling is designed, influences the patterns that can be ultimately detected. We also demonstrate the inefficiency of common sampling designs to reveal response curves between ecological variables and climatic gradients. Further, we show that response-surface methodology, which has rarely been used in ecology, is much more efficient than more traditional methods. Finally, we discuss the use of prior knowledge, simulation studies and model-based designs in defining appropriate sampling designs. We conclude by a call for development of methods to unbiasedly estimate nonlinear ecologically relevant parameters, in order to make inferences while fulfilling requirements of both sampling theory and field work logistics. ?? 2010 The Authors.
van Singer, Mathias; Chatton, Anne; Achab, Sophia; Zullino, Daniele; Rothen, Stephane; Khan, Riaz; Billieux, Joel; Thorens, Gabriel
2014-01-01
Background The number of medical studies performed through online surveys has increased dramatically in recent years. Despite their numerous advantages (eg, sample size, facilitated access to individuals presenting stigmatizing issues), selection bias may exist in online surveys. However, evidence on the representativeness of self-selected samples in online studies is patchy. Objective Our objective was to explore the representativeness of a self-selected sample of online gamers using online players’ virtual characters (avatars). Methods All avatars belonged to individuals playing World of Warcraft (WoW), currently the most widely used online game. Avatars’ characteristics were defined using various games’ scores, reported on the WoW’s official website, and two self-selected samples from previous studies were compared with a randomly selected sample of avatars. Results We used scores linked to 1240 avatars (762 from the self-selected samples and 478 from the random sample). The two self-selected samples of avatars had higher scores on most of the assessed variables (except for guild membership and exploration). Furthermore, some guilds were overrepresented in the self-selected samples. Conclusions Our results suggest that more proficient players or players more involved in the game may be more likely to participate in online surveys. Caution is needed in the interpretation of studies based on online surveys that used a self-selection recruitment procedure. Epidemiological evidence on the reduced representativeness of sample of online surveys is warranted. PMID:25001007
Defining And Characterizing Sample Representativeness For DWPF Melter Feed Samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shine, E. P.; Poirier, M. R.
2013-10-29
Representative sampling is important throughout the Defense Waste Processing Facility (DWPF) process, and the demonstrated success of the DWPF process to achieve glass product quality over the past two decades is a direct result of the quality of information obtained from the process. The objective of this report was to present sampling methods that the Savannah River Site (SRS) used to qualify waste being dispositioned at the DWPF. The goal was to emphasize the methodology, not a list of outcomes from those studies. This methodology includes proven methods for taking representative samples, the use of controlled analytical methods, and datamore » interpretation and reporting that considers the uncertainty of all error sources. Numerous sampling studies were conducted during the development of the DWPF process and still continue to be performed in order to evaluate options for process improvement. Study designs were based on use of statistical tools applicable to the determination of uncertainties associated with the data needs. Successful designs are apt to be repeated, so this report chose only to include prototypic case studies that typify the characteristics of frequently used designs. Case studies have been presented for studying in-tank homogeneity, evaluating the suitability of sampler systems, determining factors that affect mixing and sampling, comparing the final waste glass product chemical composition and durability to that of the glass pour stream sample and other samples from process vessels, and assessing the uniformity of the chemical composition in the waste glass product. Many of these studies efficiently addressed more than one of these areas of concern associated with demonstrating sample representativeness and provide examples of statistical tools in use for DWPF. The time when many of these designs were implemented was in an age when the sampling ideas of Pierre Gy were not as widespread as they are today. Nonetheless, the engineers and statisticians used carefully thought out designs that systematically and economically provided plans for data collection from the DWPF process. Key shared features of the sampling designs used at DWPF and the Gy sampling methodology were the specification of a standard for sample representativeness, an investigation that produced data from the process to study the sampling function, and a decision framework used to assess whether the specification was met based on the data. Without going into detail with regard to the seven errors identified by Pierre Gy, as excellent summaries are readily available such as Pitard [1989] and Smith [2001], SRS engineers understood, for example, that samplers can be biased (Gy's extraction error), and developed plans to mitigate those biases. Experiments that compared installed samplers with more representative samples obtained directly from the tank may not have resulted in systematically partitioning sampling errors into the now well-known error categories of Gy, but did provide overall information on the suitability of sampling systems. Most of the designs in this report are related to the DWPF vessels, not the large SRS Tank Farm tanks. Samples from the DWPF Slurry Mix Evaporator (SME), which contains the feed to the DWPF melter, are characterized using standardized analytical methods with known uncertainty. The analytical error is combined with the established error from sampling and processing in DWPF to determine the melter feed composition. This composition is used with the known uncertainty of the models in the Product Composition Control System (PCCS) to ensure that the wasteform that is produced is comfortably within the acceptable processing and product performance region. Having the advantage of many years of processing that meets the waste glass product acceptance criteria, the DWPF process has provided a considerable amount of data about itself in addition to the data from many special studies. Demonstrating representative sampling directly from the large Tank Farm tanks is a difficult, if not unsolvable enterprise due to limited accessibility. However, the consistency and the adequacy of sampling and mixing at SRS could at least be studied under the controlled process conditions based on samples discussed by Ray and others [2012a] in Waste Form Qualification Report (WQR) Volume 2 and the transfers from Tanks 40H and 51H to the Sludge Receipt and Adjustment Tank (SRAT) within DWPF. It is important to realize that the need for sample representativeness becomes more stringent as the material gets closer to the melter, and the tanks within DWPF have been studied extensively to meet those needs.« less
Kvach, Yuriy; Ondračková, Markéta; Janáč, Michal; Jurajda, Pavel
2016-08-31
In this study, we assessed the impact of sampling method on the results of fish ectoparasite studies. Common roach Rutilus rutilus were sampled from the same gravel pit in the River Dyje flood plain (Czech Republic) using 3 different sampling methods, i.e. electrofishing, beach seining and gill-netting, and were examined for ectoparasites. Not only did fish caught by electrofishing have more of the most abundant parasites (Trichodina spp., Gyrodactylus spp.) than those caught by beach seining or gill-netting, they also had relatively rich parasite infracommunities, resulting in a significantly different assemblage composition, presumably as parasites were lost through handling and 'manipulation' in the net. Based on this, we recommend electrofishing as the most suitable method to sample fish for parasite community studies, as data from fish caught with gill-nets and beach seines will provide a biased picture of the ectoparasite community, underestimating ectoparasite abundance and infracommunity species richness.
Big Data and Large Sample Size: A Cautionary Note on the Potential for Bias
Chambers, David A.; Glasgow, Russell E.
2014-01-01
Abstract A number of commentaries have suggested that large studies are more reliable than smaller studies and there is a growing interest in the analysis of “big data” that integrates information from many thousands of persons and/or different data sources. We consider a variety of biases that are likely in the era of big data, including sampling error, measurement error, multiple comparisons errors, aggregation error, and errors associated with the systematic exclusion of information. Using examples from epidemiology, health services research, studies on determinants of health, and clinical trials, we conclude that it is necessary to exercise greater caution to be sure that big sample size does not lead to big inferential errors. Despite the advantages of big studies, large sample size can magnify the bias associated with error resulting from sampling or study design. Clin Trans Sci 2014; Volume #: 1–5 PMID:25043853
Relationship between Dispositional Mindfulness and Substance Use: Findings from a Clinical Sample
Bowen, Sarah; Enkema, Matthew C.
2014-01-01
There has been rapidly increasing interest over the past decade in the potential of mindfulness-based approaches to psychological and medical treatment, including a recent growth in the area of substance abuse. Thus, the relationship between trait mindfulness and substance use has been explored in several studies. Results, however, have been mixed. While several studies of college student populations have evinced positive correlations between levels of trait mindfulness and substance use, the opposite seems to be true in clinical samples, with multiple studies showing a negative association. The current study reviews research in both non-treatment seeking college students and in clinical samples, and examines the relationship between trait mindfulness and substance dependence in a clinical sample (N = 281). Further, the study assesses the moderating effect of avoidant coping that might explain the disparate findings in the clinical versus nonclinical samples. PMID:24290208
THE NORTH CAROLINA HERALD PILOT STUDY
The sampling design for the National Children's Study (NCS) calls for a population-based, multi-stage, clustered household sampling approach. The full sample is designed to be representative of both urban and rural births in the United States, 2007-2011. While other sur...
Evaluation of Surface Sampling for Bacillus Spores Using ...
Journal Article In this study, commercially-available domestic cleaning robots were evaluated for spore surface sampling efficiency on common indoor surfaces. The current study determined the sampling efficiency of each robot, without modifying the sensors, algorithms, or logics set by the manufacturers.
40 CFR 761.323 - Sample preparation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... PROHIBITIONS Self-Implementing Alternative Extraction and Chemical Analysis Procedures for Non-liquid PCB Remediation Waste Samples § 761.323 Sample preparation. (a) The comparison study requires analysis of a... of use in this chemical extraction and chemical analysis comparison study, a person may adjust PCB...
Kalliokoski, Otto; Sørensen, Dorte B; Hau, Jann; Abelson, Klas S P
2014-01-01
Facial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups. Plasma corticosterone levels of mice subjected to tail blood sampling were also elevated, although less significantly. Mice subjected to automated blood sampling were less affected with regard to the parameters measured, and expressed less anxious behavior. We conclude that repeated blood sampling by automated blood sampling and from the tail vein is less stressful than cheek blood sampling. The choice between automated blood sampling and tail blood sampling should be based on the study requirements, the resources of the laboratory and skills of the staff. PMID:24958546
Silva, Déborah R O; Ligeiro, Raphael; Hughes, Robert M; Callisto, Marcos
2016-06-01
Taxonomic richness is one of the most important measures of biological diversity in ecological studies, including those with stream macroinvertebrates. However, it is impractical to measure the true richness of any site directly by sampling. Our objective was to evaluate the effect of sampling effort on estimates of macroinvertebrate family and Ephemeroptera, Plecoptera, and Trichoptera (EPT) genera richness at two scales: basin and stream site. In addition, we tried to determine which environmental factors at the site scale most influenced the amount of sampling effort needed. We sampled 39 sites in the Cerrado biome (neotropical savanna). In each site, we obtained 11 equidistant samples of the benthic assemblage and multiple physical habitat measurements. The observed basin-scale richness achieved a consistent estimation from Chao 1, Jack 1, and Jack 2 richness estimators. However, at the site scale, there was a constant increase in the observed number of taxa with increased number of samples. Models that best explained the slope of site-scale sampling curves (representing the necessity of greater sampling effort) included metrics that describe habitat heterogeneity, habitat structure, anthropogenic disturbance, and water quality, for both macroinvertebrate family and EPT genera richness. Our results demonstrate the importance of considering basin- and site-scale sampling effort in ecological surveys and that taxa accumulation curves and richness estimators are good tools for assessing sampling efficiency. The physical habitat explained a significant amount of the sampling effort needed. Therefore, future studies should explore the possible implications of physical habitat characteristics when developing sampling objectives, study designs, and calculating the needed sampling effort.
Flexible sampling large-scale social networks by self-adjustable random walk
NASA Astrophysics Data System (ADS)
Xu, Xiao-Ke; Zhu, Jonathan J. H.
2016-12-01
Online social networks (OSNs) have become an increasingly attractive gold mine for academic and commercial researchers. However, research on OSNs faces a number of difficult challenges. One bottleneck lies in the massive quantity and often unavailability of OSN population data. Sampling perhaps becomes the only feasible solution to the problems. How to draw samples that can represent the underlying OSNs has remained a formidable task because of a number of conceptual and methodological reasons. Especially, most of the empirically-driven studies on network sampling are confined to simulated data or sub-graph data, which are fundamentally different from real and complete-graph OSNs. In the current study, we propose a flexible sampling method, called Self-Adjustable Random Walk (SARW), and test it against with the population data of a real large-scale OSN. We evaluate the strengths of the sampling method in comparison with four prevailing methods, including uniform, breadth-first search (BFS), random walk (RW), and revised RW (i.e., MHRW) sampling. We try to mix both induced-edge and external-edge information of sampled nodes together in the same sampling process. Our results show that the SARW sampling method has been able to generate unbiased samples of OSNs with maximal precision and minimal cost. The study is helpful for the practice of OSN research by providing a highly needed sampling tools, for the methodological development of large-scale network sampling by comparative evaluations of existing sampling methods, and for the theoretical understanding of human networks by highlighting discrepancies and contradictions between existing knowledge/assumptions of large-scale real OSN data.
Nguyen, Hang Khanh Le; Nguyen, Son Vu; Nguyen, Anh Phuong; Hoang, Phuong Mai Vu; Le, Thanh Thi; Nguyen, Thach Co; Hoang, Huong Thu; Vuong, Cuong Duc; Tran, Loan Thi Thanh; Le, Mai Quynh
2017-09-25
Severe acute respiratory infections (SARI) are leading causes of hospitalization, morbidity, and mortality in children worldwide. The aim of this study was to identify viral pathogens responsible for SARI in northern Vietnam in the period from 2011 to 2014. Throat swabs and tracheal aspirates were collected from SARI patients according to WHO guidelines. The presence of 13 different viral pathogens (influenza A[H1N1]pdm09; A/H3N2; A/H5; A/H7 and B; para influenza 1,2,3; RSV; HMPV; adeno; severe acute respiratory syndrome-CoV and rhino) was tested by conventional/real-time reverse transcription-polymerase chain reaction. During the study period, 975 samples were collected and tested. More than 30% (32.1%, 313 samples) of the samples showed evidence of infection with influenza viruses, including A/H3N2 (48 samples), A (H1N1) pdm09 (221 samples), influenza B (42 samples), and co-infection of A (H1N1) pdm09 or A/H3N2 and influenza B (2 samples). Other respiratory pathogens were detected in 101 samples, including rhinovirus (73 samples), adenovirus (10 samples), hMPV (9 samples), parainfluenza 3 (5 samples), parainfluenza 2 (3 samples), and RSV (1 sample). Influenza A/H5, A/H7, or SARS-CoV were not detected. Respiratory viral infection, particularly infection of influenza and rhinoviruses, were associated with high rates of SARI hospitalization, and future studies correlating the clinical aspects are needed to design interventions, including targeted vaccination.
The Metals in Replicate Samples data set contains the analytical results of measurements of up to 2 metals in 172 replicate (duplicate) samples from 86 households. Measurements were made in samples of blood. Duplicate samples for a small percentage of the total number of sample...
Nanopipettes: probes for local sample analysis.
Saha-Shah, Anumita; Weber, Anna E; Karty, Jonathan A; Ray, Steven J; Hieftje, Gary M; Baker, Lane A
2015-06-01
Nanopipettes (pipettes with diameters <1 μm) were explored as pressure-driven fluid manipulation tools for sampling nanoliter volumes of fluids. The fundamental behavior of fluids confined in the narrow channels of the nanopipette shank was studied to optimize sampling volume and probe geometry. This method was utilized to collect nanoliter volumes (<10 nL) of sample from single Allium cepa cells and live Drosophila melanogaster first instar larvae. Matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) was utilized to characterize the collected sample. The use of nanopipettes for surface sampling of mouse brain tissue sections was also explored. Lipid analyses were performed on mouse brain tissues with spatial resolution of sampling as small as 50 μm. Nanopipettes were shown to be a versatile tool that will find further application in studies of sample heterogeneity and population analysis for a wide range of samples.
Olives, Casey; Pagano, Marcello; Deitchler, Megan; Hedt, Bethany L; Egge, Kari; Valadez, Joseph J
2009-04-01
Traditional lot quality assurance sampling (LQAS) methods require simple random sampling to guarantee valid results. However, cluster sampling has been proposed to reduce the number of random starting points. This study uses simulations to examine the classification error of two such designs, a 67x3 (67 clusters of three observations) and a 33x6 (33 clusters of six observations) sampling scheme to assess the prevalence of global acute malnutrition (GAM). Further, we explore the use of a 67x3 sequential sampling scheme for LQAS classification of GAM prevalence. Results indicate that, for independent clusters with moderate intracluster correlation for the GAM outcome, the three sampling designs maintain approximate validity for LQAS analysis. Sequential sampling can substantially reduce the average sample size that is required for data collection. The presence of intercluster correlation can impact dramatically the classification error that is associated with LQAS analysis.
Fernández de la Ossa, Ma Ángeles; Ortega-Ojeda, Fernando; García-Ruiz, Carmen
2013-08-09
This work is focused on a novel procedure to discriminate nitrocellulose-based samples with non-explosive and explosive properties. The nitrocellulose study has been scarcely approached in the literature due to its special polymeric properties such as its high molar mass and complex chemical and structural characteristics. These properties require the nitrocellulose analysis to be performed by using a few organic solvents and in consequence, they limit the number of adequate analytical techniques for its study. In terms of identification of pre-blast explosives, mass spectrometry is one of the most preferred technique because it allows to obtain structural information. However, it has never been used to analyze polymeric nitrocellulose. In this study, the differentiation of non-explosive and explosive samples through nitrocellulose fingerprints obtained by capillary electrophoresis was investigated. A batch of 30 different smokeless gunpowders and 23 different everyday products were pulverized, derivatized with a fluorescent agent and analyzed by capillary electrophoresis with laser-induced fluorescence detection. Since this methodology is specific to d-glucopyranose derivatives (cellulosic and related compounds), and paper samples could be easily found in explosion scenes, 11 different paper samples were also included in the study as potential interference samples. In order to discriminate among samples, multivariate analysis (principal component analysis and soft independent modeling of class analogy) was applied to the obtained electrophoretic profiles. To the best of our knowledge, this represents the first study that achieve a successful discrimination between non-explosive and explosive nitrocellulose-based samples, as well as potential cellulose interference samples, and posterior classification of unknown samples into their corresponding groups using CE-LIF and chemometric tools. Copyright © 2013 Elsevier B.V. All rights reserved.
Schram-Bijkerk, D; Doekes, G; Boeve, M; Douwes, J; Riedler, J; Ublagger, E; von Mutius, E; Benz, M; Pershagen, G; Wickman, M; Alfvén, T; Braun-Fahrländer, C; Waser, M; Brunekreef, B
2006-12-01
Dust collection by study participants instead of fieldworkers would be a practical and cost-effective alternative in large-scale population studies estimating exposure to indoor allergens and microbial agents. We aimed to compare dust weights and biological agent levels in house dust samples taken by study participants with nylon socks, with those in samples taken by fieldworkers using the sampling nozzle of the Allergology Laboratory Copenhagen (ALK). In homes of 216 children, parents and fieldworkers collected house dust within the same year. Dust samples were analyzed for levels of allergens, endotoxin, (1-->3)-beta-D-glucans and fungal extracellular polysaccharides (EPS). Socks appeared to yield less dust from mattresses at relatively low dust amounts and more dust at high dust amounts than ALK samples. Correlations between the methods ranged from 0.47-0.64 for microbial agents and 0.64-0.87 for mite and pet allergens. Cat allergen levels were two-fold lower and endotoxin levels three-fold higher in socks than in ALK samples. Levels of allergens and microbial agents in sock samples taken by study participants are moderately to highly correlated to levels in ALK samples taken by fieldworkers. Absolute levels may differ, probably because of differences in the method rather than in the person who performed the sampling. Practical Implications Dust collection by participants is a reliable and practical option for allergen and microbial agent exposure assessment. Absolute levels of biological agents are not (always) comparable between studies using different dust collection methods, even when expressed per gram dust, because of potential differences in particle-size constitution of the collected dust.
A study on rate of infestation to Sarcocystis cysts in supplied raw hamburgers.
Nematollahia, Ahmad; Khoshkerdar, Afsaneh; Helan, Javad Ashrafi; Shahbazi, Parisa; Hassanzadeh, Parviz
2015-06-01
This study was carried on for determination of presence of Sarcocystis cysts in raw hamburgers in Tabriz North West of Iran. Ninety-six samples of industrial (70 % meat content) and traditional (30 % meat content) hamburgers (80 samples industrial and 16 samples traditional) were obtained from retail fast food stores. The samples were examined by gross examination, and microscopic examination methods consist impression smear and peptic digestion. Macroscopic cysts did not observed in any of the samples in gross examination. Microscopic study showed that from 96 samples 54 (56.25 %) samples were infected by at least one bradyzoites of Sarcocystis. From 54 infected samples, 45 industrial hamburgers and nine traditional hamburgers samples were infected. Statistical analysis showed that there was not significant differences between industrial and traditional hamburgers in infection to Sarcocystis. Infestation of hamburgers to Sarcocystis in summer was higher than other seasons but this difference was not significant. In Iran, beef meat is used for preparation of 70 % of hamburger and infestation of cattle to sarcocystosis was reported in many investigations in Iran. With regard to the high prevalence of Sarcocystis infection in meat products such as hamburgers in this study, it is strongly recommended to avoid eating raw or under-cooked hamburgers or keep them at freezing temperature for at least 3-5 days.
Sample size for post-marketing safety studies based on historical controls.
Wu, Yu-te; Makuch, Robert W
2010-08-01
As part of a drug's entire life cycle, post-marketing studies are an important part in the identification of rare, serious adverse events. Recently, the US Food and Drug Administration (FDA) has begun to implement new post-marketing safety mandates as a consequence of increased emphasis on safety. The purpose of this research is to provide exact sample size formula for the proposed hybrid design, based on a two-group cohort study with incorporation of historical external data. Exact sample size formula based on the Poisson distribution is developed, because the detection of rare events is our outcome of interest. Performance of exact method is compared to its approximate large-sample theory counterpart. The proposed hybrid design requires a smaller sample size compared to the standard, two-group prospective study design. In addition, the exact method reduces the number of subjects required in the treatment group by up to 30% compared to the approximate method for the study scenarios examined. The proposed hybrid design satisfies the advantages and rationale of the two-group design with smaller sample sizes generally required. 2010 John Wiley & Sons, Ltd.
Lee, Hye-Seung; Burkhardt, Brant R; McLeod, Wendy; Smith, Susan; Eberhard, Chris; Lynch, Kristian; Hadley, David; Rewers, Marian; Simell, Olli; She, Jin-Xiong; Hagopian, Bill; Lernmark, Ake; Akolkar, Beena; Ziegler, Anette G; Krischer, Jeffrey P
2014-07-01
The Environmental Determinants of Diabetes in the Young planned biomarker discovery studies on longitudinal samples for persistent confirmed islet cell autoantibodies and type 1 diabetes using dietary biomarkers, metabolomics, microbiome/viral metagenomics and gene expression. This article describes the details of planning The Environmental Determinants of Diabetes in the Young biomarker discovery studies using a nested case-control design that was chosen as an alternative to the full cohort analysis. In the frame of a nested case-control design, it guides the choice of matching factors, selection of controls, preparation of external quality control samples and reduction of batch effects along with proper sample allocation. Our design is to reduce potential bias and retain study power while reducing the costs by limiting the numbers of samples requiring laboratory analyses. It also covers two primary end points (the occurrence of diabetes-related autoantibodies and the diagnosis of type 1 diabetes). The resulting list of case-control matched samples for each laboratory was augmented with external quality control samples. Copyright © 2013 John Wiley & Sons, Ltd.
Kano, Eunice Kazue; Chiann, Chang; Fukuda, Kazuo; Porta, Valentina
2017-08-01
Bioavailability and bioequivalence study is one of the most frequently performed investigations in clinical trials. Bioequivalence testing is based on the assumption that 2 drug products will be therapeutically equivalent when they are equivalent in the rate and extent to which the active drug ingredient or therapeutic moiety is absorbed and becomes available at the site of drug action. In recent years there has been a significant growth in published papers that use in silico studies based on mathematical simulations to analyze pharmacokinetic and pharmacodynamic properties of drugs, including bioavailability and bioequivalence aspects. The goal of this study is to evaluate the usefulness of in silico studies as a tool in the planning of bioequivalence, bioavailability and other pharmacokinetic assays, e.g., to determine an appropriate sampling schedule. Monte Carlo simulations were used to define adequate blood sampling schedules for a bioequivalence assay comparing 2 different formulations of cefadroxil oral suspensions. In silico bioequivalence studies comparing different formulation of cefadroxil oral suspensions using various sampling schedules were performed using models. An in vivo study was conducted to confirm in silico results. The results of in silico and in vivo bioequivalence studies demonstrated that schedules with fewer sampling times are as efficient as schedules with larger numbers of sampling times in the assessment of bioequivalence, but only if T max is included as a sampling time. It was also concluded that in silico studies are useful tools in the planning of bioequivalence, bioavailability and other pharmacokinetic in vivo assays. © Georg Thieme Verlag KG Stuttgart · New York.
Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing
Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre
2016-01-01
The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated. PMID:27196899
Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing.
Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre
2016-05-17
The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated.
Dole-Olivier, Marie-José; Galassi, Diana M. P.; Hogan, John-Paul; Wood, Paul J.
2016-01-01
The hyporheic zone of river ecosystems provides a habitat for a diverse macroinvertebrate community that makes a vital contribution to ecosystem functioning and biodiversity. However, effective methods for sampling this community have proved difficult to establish, due to the inaccessibility of subsurface sediments. The aim of this study was to compare the two most common semi-quantitative macroinvertebrate pump-sampling techniques: Bou-Rouch and vacuum-pump sampling. We used both techniques to collect replicate samples in three contrasting temperate-zone streams, in each of two biogeographical regions (Atlantic region, central England, UK; Continental region, southeast France). Results were typically consistent across streams in both regions: Bou-Rouch samples provided significantly higher estimates of taxa richness, macroinvertebrate abundance, and the abundance of all UK and eight of 10 French common taxa. Seven and nine taxa which were rare in Bou-Rouch samples were absent from vacuum-pump samples in the UK and France, respectively; no taxon was repeatedly sampled exclusively by the vacuum pump. Rarefaction curves (rescaled to the number of incidences) and non-parametric richness estimators indicated no significant difference in richness between techniques, highlighting the capture of more individuals as crucial to Bou-Rouch sampling performance. Compared to assemblages in replicate vacuum-pump samples, multivariate analyses indicated greater distinction among Bou-Rouch assemblages from different streams, as well as significantly greater consistency in assemblage composition among replicate Bou-Rouch samples collected in one stream. We recommend Bou-Rouch sampling for most study types, including rapid biomonitoring surveys and studies requiring acquisition of comprehensive taxon lists that include rare taxa. Despite collecting fewer macroinvertebrates, vacuum-pump sampling remains an important option for inexpensive and rapid sample collection. PMID:27723819
Smith, Blair H; Hannaford, Philip C; Elliott, Alison M; Smith, W Cairns; Chambers, W Alastair
2005-04-01
Sampling for primary care research must strike a balance between efficiency and external validity. For most conditions, even a large population sample will yield a small number of cases, yet other sampling techniques risk problems with extrapolation of findings. To compare the efficiency and external validity of two sampling methods for both an intervention study and epidemiological research in primary care--a convenience sample and a general population sample--comparing the response and follow-up rates, the demographic and clinical characteristics of each sample, and calculating the 'number needed to sample' (NNS) for a hypothetical randomized controlled trial. In 1996, we selected two random samples of adults from 29 general practices in Grampian, for an epidemiological study of chronic pain. One sample of 4175 was identified by an electronic questionnaire that listed patients receiving regular analgesic prescriptions--the 'repeat prescription sample'. The other sample of 5036 was identified from all patients on practice lists--the 'general population sample'. Questionnaires, including demographic, pain and general health measures, were sent to all. A similar follow-up questionnaire was sent in 2000 to all those agreeing to participate in further research. We identified a potential group of subjects for a hypothetical trial in primary care based on a recently published trial (those aged 25-64, with severe chronic back pain, willing to participate in further research). The repeat prescription sample produced better response rates than the general sample overall (86% compared with 82%, P < 0.001), from both genders and from the oldest and youngest age groups. The NNS using convenience sampling was 10 for each member of the final potential trial sample, compared with 55 using general population sampling. There were important differences between the samples in age, marital and employment status, social class and educational level. However, among the potential trial sample, there were no demographic differences. Those from the repeat prescription sample had poorer indices than the general population sample in all pain and health measures. The repeat prescription sampling method was approximately five times more efficient than the general population method. However demographic and clinical differences in the repeat prescription sample might hamper extrapolation of findings to the general population, particularly in an epidemiological study, and demonstrate that simple comparison with age and gender of the target population is insufficient.
Acoustically levitated droplets: a contactless sampling method for fluorescence studies.
Leiterer, Jork; Grabolle, Markus; Rurack, Knut; Resch-Genger, Ute; Ziegler, Jan; Nann, Thomas; Panne, Ulrich
2008-01-01
Acoustic levitation is used as a new tool to study concentration-dependent processes in fluorescence spectroscopy. With this technique, small amounts of liquid and solid samples can be measured without the need for sample supports or containers, which often limits signal acquisition and can even alter sample properties due to interactions with the support material. We demonstrate that, because of the small sample volume, fluorescence measurements at high concentrations of an organic dye are possible without the limitation of inner-filter effects, which hamper such experiments in conventional, cuvette-based measurements. Furthermore, we show that acoustic levitation of liquid samples provides an experimentally simple way to study distance-dependent fluorescence modulations in semiconductor nanocrystals. The evaporation of the solvent during levitation leads to a continuous increase of solute concentration and can easily be monitored by laser-induced fluorescence.
Synthesis and characterization of silicon nanorod on n-type porous silicon.
Behzad, Kasra; Mat Yunus, Wan Mahmood; Bahrami, Afarin; Kharazmi, Alireza; Soltani, Nayereh
2016-03-20
This work reports a new method for growing semiconductor nanorods on a porous silicon substrate. After preparation of n-type porous silicon samples, a thin layer of gold was deposited on them. Gold deposited samples were annealed at different temperatures. The structural, thermal, and optical properties of the samples were studied using a field emission scanning electron microscope (FESEM), photoacoustic spectroscopy, and photoluminescence spectroscopy, respectively. FESEM analysis revealed that silicon nanorods of different sizes grew on the annealed samples. Thermal behavior of the samples was studied using photoacoustic spectroscopy. Photoluminescence spectroscopy showed that the emission peaks were degraded by gold deposition and attenuated for all samples by annealing.
NASA Technical Reports Server (NTRS)
McConnell, Joshua B.
2000-01-01
The scientific exploration of Mars will require the collection and return of subterranean samples to Earth for examination. This necessitates the use of some type of device or devices that possesses the ability to effectively penetrate the Martian surface, collect suitable samples and return them to the surface in a manner consistent with imposed scientific constraints. The first opportunity for such a device will occur on the 2003 and 2005 Mars Sample Return missions, being performed by NASA. This paper reviews the work completed on the compilation of a database containing viable penetrating and sampling devices, the performance of a system level trade study comparing selected devices to a set of prescribed parameters and the employment of a metric for the evaluation and ranking of the traded penetration and sampling devices, with respect to possible usage on the 03 and 05 sample return missions. The trade study performed is based on a select set of scientific, engineering, programmatic and socio-political criterion. The use of a metric for the various penetration and sampling devices will act to expedite current and future device selection.
Influence of various water quality sampling strategies on load estimates for small streams
Robertson, Dale M.; Roerish, Eric D.
1999-01-01
Extensive streamflow and water quality data from eight small streams were systematically subsampled to represent various water‐quality sampling strategies. The subsampled data were then used to determine the accuracy and precision of annual load estimates generated by means of a regression approach (typically used for big rivers) and to determine the most effective sampling strategy for small streams. Estimation of annual loads by regression was imprecise regardless of the sampling strategy used; for the most effective strategy, median absolute errors were ∼30% based on the load estimated with an integration method and all available data, if a regression approach is used with daily average streamflow. The most effective sampling strategy depends on the length of the study. For 1‐year studies, fixed‐period monthly sampling supplemented by storm chasing was the most effective strategy. For studies of 2 or more years, fixed‐period semimonthly sampling resulted in not only the least biased but also the most precise loads. Additional high‐flow samples, typically collected to help define the relation between high streamflow and high loads, result in imprecise, overestimated annual loads if these samples are consistently collected early in high‐flow events.
Volunteer Functions Inventory: A systematic review.
Chacón, Fernando; Gutiérrez, Gema; Sauto, Verónica; Vecina, María L; Pérez, Alfonso
2017-08-01
The objective of this research study was to conduct a systematic review of the research on volunteers using Clary et al.’s VFI (1998). A total of 48 research studies including 67 independent samples met eligibility criteria. The total sample of the studies analyzed ranged from 20375 to 21988 participants, depending on the motivation analyzed. The results show that the Values factor obtained the highest mean score, both overall and in each type of volunteering, whereas the lowest scores were for the Career and Enhancement factors. Studies conducted with samples with a mean age under 40 years obtain higher scores on Career and Understanding scales when compared to studies in older samples. The group of studies with less than 50% women yield higher mean scores on the Social scale than studies with more than 50% women in the sample. All the scales show reliability coefficients between .78 and .84. Only eight of the articles provide data on the reliability of the scale with a mean value of .90. Of the 26 studies that performed factor analysis, 18 confirmed the original structure of six factors.
Cuvelier, Daphne; de Busserolles, Fanny; Lavaud, Romain; Floc'h, Estelle; Fabri, Marie-Claire; Sarradin, Pierre-Marie; Sarrazin, Jozée
2012-12-01
In the past few decades, hydrothermal vent research has progressed immensely, resulting in higher-quality samples and long-term studies. With time, scientists are becoming more aware of the impacts of sampling on the faunal communities and are looking for less invasive ways to investigate the vent ecosystems. In this perspective, imagery analysis plays a very important role. With this study, we test which factors can be quantitatively and accurately assessed based on imagery, through comparison with faunal sampling. Twelve instrumented chains were deployed on the Atlantic Eiffel Tower hydrothermal edifice and the corresponding study sites were subsequently sampled. Discrete, quantitative samples were compared to the imagery recorded during the experiment. An observer-effect was tested, by comparing imagery data gathered by different scientists. Most factors based on image analyses concerning Bathymodiolus azoricus mussels were shown to be valid representations of the corresponding samples. Additional ecological assets, based exclusively on imagery, were included. Copyright © 2012 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Santos, Antonio J.; Peceguina, Ines; Daniel, Joao R.; Shin, Nana; Vaughn, Brian E.
2013-01-01
This study tested assumptions and conclusions reached in an earlier confirmatory factor analysis (CFA) study of the social competence (SC) construct for preschool children. Two samples (total N = 408; a new Portuguese sample and one from US samples that had participated in the original study) contributed data. Seven SC indicators were tested for…
Observations of radiation fog chemistry in the Eastern United States
NASA Astrophysics Data System (ADS)
Straub, D.; Hutchings, J.; Herckes, P.
2010-07-01
The chemical composition of radiation fog in the Mid-Atlantic region of the United States has been the focus of an ongoing field campaign based in Selinsgrove, PA. This field study was established to provide a long term record that can be used to identify the effects of meteorology and air mass source regions on fog composition and to shed light on the role that fog can play in the production of secondary inorganic and organic aerosol mass. In the United States, studies that focus on radiation fog have been relatively rare. For the most part, they have been limited geographically to the Central Valley of California, though individual studies have also been conducted in the Central United States and along the Texas-Louisiana Gulf Coast. Sample collection for the current study began during the fall of 2007. Through 2009, samples from 25 radiation fog events have been obtained. A Caltech Heated Rod Cloudwater Collector (CHRCC) having a Dp50 of approximately 8 microns was used to collect one fog sample per event. Samples were typically collected between 2:00 AM and 7:00 AM under conditions of light winds, clear skies, and recent rainfall. Sample volumes ranged from 2.9 ml to 150 ml. Following collection, samples were analyzed for pH and then one of the following: major inorganic ions, dissolved total organic carbon, N-nitrosodimethylamine (NDMA), metals, or organic speciation. Through 2009, sample pH varied between 4.28 and 6.86 and averaged 5.03 based on H+ concentration. Ammonium and sulfate were found to be the most abundant ionic species in the fog samples. Sufficient ammonium was detected in nearly every sample to fully neutralize nitrate and sulfate. The concentrations of sulfate, nitrate, and ammonium observed in this study were lower than values reported in the literature for most other cloud and fog studies conducted in the US. Due to significant ammonium input, pH in the current study was higher than most other studies. Concentrations of total organic carbon averaged 7.22 mgC/L, which is lower than other radiation fogs studies but similar to that for many cloud studies. NDMA concentrations in two analyzed samples were considered high, but not outside the range that could be expected through equilibrium with potential gas phase concentrations.
Sub-sampling genetic data to estimate black bear population size: A case study
Tredick, C.A.; Vaughan, M.R.; Stauffer, D.F.; Simek, S.L.; Eason, T.
2007-01-01
Costs for genetic analysis of hair samples collected for individual identification of bears average approximately US$50 [2004] per sample. This can easily exceed budgetary allowances for large-scale studies or studies of high-density bear populations. We used 2 genetic datasets from 2 areas in the southeastern United States to explore how reducing costs of analysis by sub-sampling affected precision and accuracy of resulting population estimates. We used several sub-sampling scenarios to create subsets of the full datasets and compared summary statistics, population estimates, and precision of estimates generated from these subsets to estimates generated from the complete datasets. Our results suggested that bias and precision of estimates improved as the proportion of total samples used increased, and heterogeneity models (e.g., Mh[CHAO]) were more robust to reduced sample sizes than other models (e.g., behavior models). We recommend that only high-quality samples (>5 hair follicles) be used when budgets are constrained, and efforts should be made to maximize capture and recapture rates in the field.
Fernández, Diego; Vermeirssen, Etiënne L M; Bandow, Nicole; Muñoz, Katherine; Schäfer, Ralf B
2014-11-01
Rainfall-triggered runoff is a major driver of pesticide input in streams. Only few studies have examined the suitability of passive sampling to quantify such episodic exposures. In this study, we used Empore™ styrene-divinylbenzene reverse phase sulfonated disks (SDB disks) and event-driven water samples (EDS) to assess exposure to 15 fungicides and 4 insecticides in 17 streams in a German vineyard area during 4 rainfall events. We also conducted a microcosm experiment to determine the SDB-disk sampling rates and provide a free-software solution to derive sampling rates under time-variable exposure. Sampling rates ranged from 0.26 to 0.77 L d(-1) and time-weighted average (TWA) concentrations from 0.05 to 2.11 μg/L. The 2 sampling systems were in good agreement and EDS exceeded TWA concentrations on average by a factor of 3. Our study demonstrates that passive sampling is suitable to quantify episodic exposures from polar organic pesticides. Copyright © 2014 Elsevier Ltd. All rights reserved.
Zhao, Qi; Liu, Yuanning; Zhang, Ning; Hu, Menghan; Zhang, Hao; Joshi, Trupti; Xu, Dong
2018-01-01
In recent years, an increasing number of studies have reported the presence of plant miRNAs in human samples, which resulted in a hypothesis asserting the existence of plant-derived exogenous microRNA (xenomiR). However, this hypothesis is not widely accepted in the scientific community due to possible sample contamination and the small sample size with lack of rigorous statistical analysis. This study provides a systematic statistical test that can validate (or invalidate) the plant-derived xenomiR hypothesis by analyzing 388 small RNA sequencing data from human samples in 11 types of body fluids/tissues. A total of 166 types of plant miRNAs were found in at least one human sample, of which 14 plant miRNAs represented more than 80% of the total plant miRNAs abundance in human samples. Plant miRNA profiles were characterized to be tissue-specific in different human samples. Meanwhile, the plant miRNAs identified from microbiome have an insignificant abundance compared to those from humans, while plant miRNA profiles in human samples were significantly different from those in plants, suggesting that sample contamination is an unlikely reason for all the plant miRNAs detected in human samples. This study also provides a set of testable synthetic miRNAs with isotopes that can be detected in situ after being fed to animals.
NASA Astrophysics Data System (ADS)
Edgcomb, V. P.; Taylor, C.; Pachiadaki, M. G.; Honjo, S.; Engstrom, I.; Yakimov, M.
2016-07-01
Obtaining an accurate picture of microbial processes occurring in situ is essential for our understanding of marine biogeochemical cycles of global importance. Water samples are typically collected at depth and returned to the sea surface for processing and downstream experiments. Metatranscriptome analysis is one powerful approach for investigating metabolic activities of microorganisms in their habitat and which can be informative for determining responses of microbiota to disturbances such as the Deepwater Horizon oil spill. For studies of microbial processes occurring in the deep sea, however, sample handling, pressure, and other changes during sample recovery can subject microorganisms to physiological changes that alter the expression profile of labile messenger RNA. Here we report a comparison of gene expression profiles for whole microbial communities in a bathypelagic water column sample collected in the Eastern Mediterranean Sea using Niskin bottle sample collection and a new water column sampler for studies of marine microbial ecology, the Microbial Sampler - In Situ Incubation Device (MS-SID). For some taxa, gene expression profiles from samples collected and preserved in situ were significantly different from potentially more stressful Niskin sampling and preservation on deck. Some categories of transcribed genes also appear to be affected by sample handling more than others. This suggests that for future studies of marine microbial ecology, particularly targeting deep sea samples, an in situ sample collection and preservation approach should be considered.
Protocol Improvements for Low Concentration DNA-Based Bioaerosol Sampling and Analysis
Ng, Chun Kiat; Miller, Dana; Cao, Bin
2015-01-01
Introduction As bioaerosol research attracts increasing attention, there is a need for additional efforts that focus on method development to deal with different environmental samples. Bioaerosol environmental samples typically have very low biomass concentrations in the air, which often leaves researchers with limited options in choosing the downstream analysis steps, especially when culture-independent methods are intended. Objectives This study investigates the impacts of three important factors that can influence the performance of culture-independent DNA-based analysis in dealing with bioaerosol environmental samples engaged in this study. The factors are: 1) enhanced high temperature sonication during DNA extraction; 2) effect of sampling duration on DNA recoverability; and 3) an alternative method for concentrating composite samples. In this study, DNA extracted from samples was analysed using the Qubit fluorometer (for direct total DNA measurement) and quantitative polymerase chain reaction (qPCR). Results and Findings The findings suggest that additional lysis from high temperature sonication is crucial: DNA yields from both high and low biomass samples increased up to 600% when the protocol included 30-min sonication at 65°C. Long air sampling duration on a filter media was shown to have a negative impact on DNA recoverability with up to 98% of DNA lost over a 20-h sampling period. Pooling DNA from separate samples during extraction was proven to be feasible with margins of error below 30%. PMID:26619279
Rapid regrowth and detection of microbial contaminants in equine fecal microbiome samples
Beckers, Kalie F.; Childers, Gary W.
2017-01-01
Advances have been made to standardize 16S rRNA gene amplicon based studies for inter-study comparisons, yet there are many opportunities for systematic error that may render these comparisons improper and misleading. The fecal microbiome of horses has been examined previously, however, no universal horse fecal collection method and sample processing procedure has been established. This study was initialized in large part to ensure that samples collected by different individuals from different geographical areas (i.e., crowdsourced) were not contaminated due to less than optimal sampling or holding conditions. In this study, we examined the effect of sampling the surface of fecal pellets compared to homogenized fecal pellets, and also the effect of time of sampling after defecation on ‘bloom’ taxa (bloom taxa refers to microbial taxa that can grow rapidly in horse feces post-defecation) using v4 16S rRNA amplicon libraries. A total of 1,440,171 sequences were recovered from 65 horse fecal samples yielding a total of 3,422 OTUs at 97% similarity. Sampling from either surface or homogenized feces had no effect on diversity and little effect on microbial composition. Sampling at various time points (0, 2, 4, 6, 12 h) had a significant effect on both diversity and community composition of fecal samples. Alpha diversity (Shannon index) initially increased with time as regrowth taxa were detected in the amplicon libraries, but by 12 h the diversity sharply decreased as the community composition became dominated by a few bloom families, including Bacillaceae, Planococcaeae, and Enterococcaceae, and other families to a lesser extent. The results show that immediate sampling of horse feces must be done in order to ensure accurate representation of horse fecal samples. Also, several of the bloom taxa found in this study are known to occur in human and cattle feces post defecation. The dominance of these taxa in feces shortly after defecation suggests that the feces is an important habitat for these organisms, and horse fecal samples that were improperly stored can be identified by presence of bloom taxa. PMID:29091944
The Generation R Study: Biobank update 2015.
Kruithof, Claudia J; Kooijman, Marjolein N; van Duijn, Cornelia M; Franco, Oscar H; de Jongste, Johan C; Klaver, Caroline C W; Mackenbach, Johan P; Moll, Henriëtte A; Raat, Hein; Rings, Edmond H H M; Rivadeneira, Fernando; Steegers, Eric A P; Tiemeier, Henning; Uitterlinden, Andre G; Verhulst, Frank C; Wolvius, Eppo B; Hofman, Albert; Jaddoe, Vincent W V
2014-12-01
The Generation R Study is a population-based prospective cohort study from fetal life until adulthood. The study is designed to identify early environmental and genetic causes and causal pathways leading to normal and abnormal growth, development and health from fetal life, childhood and young adulthood. In total, 9,778 mothers were enrolled in the study. Data collection in children and their parents include questionnaires, interviews, detailed physical and ultrasound examinations, behavioural observations, Magnetic Resonance Imaging and biological samples. Efforts have been conducted for collecting biological samples including blood, hair, faeces, nasal swabs, saliva and urine samples and generating genomics data on DNA, RNA and microbiome. In this paper, we give an update of the collection, processing and storage of these biological samples and available measures. Together with detailed phenotype measurements, these biological samples provide a unique resource for epidemiological studies focused on environmental exposures, genetic and genomic determinants and their interactions in relation to growth, health and development from fetal life onwards.
Comparison of Fecal Collection Methods for Microbiota Studies in Bangladesh
Chen, Jun; Kibriya, Muhammad G.; Chen, Yu; Islam, Tariqul; Eunes, Mahbubul; Ahmed, Alauddin; Naher, Jabun; Rahman, Anisur; Amir, Amnon; Shi, Jianxin; Abnet, Christian C.; Nelson, Heidi; Knight, Rob; Chia, Nicholas; Ahsan, Habibul; Sinha, Rashmi
2017-01-01
ABSTRACT To our knowledge, fecal microbiota collection methods have not been evaluated in low- and middle-income countries. Therefore, we evaluated five different fecal sample collection methods for technical reproducibility, stability, and accuracy within the Health Effects of Arsenic Longitudinal Study (HEALS) in Bangladesh. Fifty participants from the HEALS provided fecal samples in the clinic which were aliquoted into no solution, 95% ethanol, RNAlater, postdevelopment fecal occult blood test (FOBT) cards, and fecal immunochemical test (FIT) tubes. Half of the aliquots were frozen immediately at −80°C (day 0) and the remaining samples were left at ambient temperature for 96 h and then frozen (day 4). Intraclass correlation coefficients (ICC) were calculated for the relative abundances of the top three phyla, for two alpha diversity measures, and for four beta diversity measures. The duplicate samples had relatively high ICCs for technical reproducibility at day 0 and day 4 (range, 0.79 to 0.99). The FOBT card and samples preserved in RNAlater and 95% ethanol had the highest ICCs for stability over 4 days. The FIT tube had lower stability measures overall. In comparison to the “gold standard” method using immediately frozen fecal samples with no solution, the ICCs for many of the microbial metrics were low, but the rank order appeared to be preserved as seen by the Spearman correlation. The FOBT cards, 95% ethanol, and RNAlater were effective fecal preservatives. These fecal collection methods are optimal for future cohort studies, particularly in low- and middle-income countries. IMPORTANCE The collection of fecal samples in prospective cohort studies is essential to provide the opportunity to study the effect of the human microbiota on numerous health conditions. However, these collection methods have not been adequately tested in low- and middle-income countries. We present estimates of technical reproducibility, stability at ambient temperature for 4 days, and accuracy comparing a “gold standard” for fecal samples in no solution, 95% ethanol, RNAlater, postdevelopment fecal occult blood test cards, and fecal immunochemical test tubes in a study conducted in Bangladesh. Fecal occult blood test cards and fecal samples stored in 95% ethanol or RNAlater adequately preserve fecal samples in this setting. Therefore, new studies in low- and middle-income countries should include collection of fecal samples using fecal occult blood test cards, 95% ethanol, or RNAlater for prospective cohort studies. PMID:28258145
Al-Shamary, Noora M; Al-Ghouti, Mohammad A; Al-Shaikh, Ismail; Al-Meer, Saeed H; Ahmad, Talaat A
2016-03-01
The study aimed to examine the residues of organochlorines pesticides (OCPs) in vegetables and fruits in Qatar. A total of 127 samples was studied. Ninety percent of the imported samples recorded residues above the maximum residue levels (MRLs). The most frequently detected OCP in the samples was heptachlor (found in 75 samples). In the comparisons between the washed and unwashed samples, no significant differences were observed (P > 0.05). However, the effect of washing process with tap water depended on the type of vegetables and fruits.
40 CFR 761.323 - Sample preparation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 761.323 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL... Remediation Waste Samples § 761.323 Sample preparation. (a) The comparison study requires analysis of a minimum of 10 samples weighing at least 300 grams each. Samples of PCB remediation waste used in the...
40 CFR 761.323 - Sample preparation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 761.323 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL... Remediation Waste Samples § 761.323 Sample preparation. (a) The comparison study requires analysis of a minimum of 10 samples weighing at least 300 grams each. Samples of PCB remediation waste used in the...
40 CFR 761.323 - Sample preparation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 761.323 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL... Remediation Waste Samples § 761.323 Sample preparation. (a) The comparison study requires analysis of a minimum of 10 samples weighing at least 300 grams each. Samples of PCB remediation waste used in the...
Molecular epidemiology biomarkers-Sample collection and processing considerations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holland, Nina T.; Pfleger, Laura; Berger, Eileen
2005-08-07
Biomarker studies require processing and storage of numerous biological samples with the goals of obtaining a large amount of information and minimizing future research costs. An efficient study design includes provisions for processing of the original samples, such as cryopreservation, DNA isolation, and preparation of specimens for exposure assessment. Use of standard, two-dimensional and nanobarcodes and customized electronic databases assure efficient management of large sample collections and tracking results of data analyses. Standard operating procedures and quality control plans help to protect sample quality and to assure validity of the biomarker data. Specific state, federal and international regulations are inmore » place regarding research with human samples, governing areas including custody, safety of handling, and transport of human samples. Appropriate informed consent must be obtained from the study subjects prior to sample collection and confidentiality of results maintained. Finally, examples of three biorepositories of different scale (European Cancer Study, National Cancer Institute and School of Public Health Biorepository, University of California, Berkeley) are used to illustrate challenges faced by investigators and the ways to overcome them. New software and biorepository technologies are being developed by many companies that will help to bring biological banking to a new level required by molecular epidemiology of the 21st century.« less
Xu, Jiao; Li, Mei; Shi, Guoliang; Wang, Haiting; Ma, Xian; Wu, Jianhui; Shi, Xurong; Feng, Yinchang
2017-11-15
In this study, single particle mass spectra signatures of both coal burning boiler and biomass burning boiler emitted particles were studied. Particle samples were suspended in clean Resuspension Chamber, and analyzed by ELPI and SPAMS simultaneously. The size distribution of BBB (biomass burning boiler sample) and CBB (coal burning boiler sample) are different, as BBB peaks at smaller size, and CBB peaks at larger size. Mass spectra signatures of two samples were studied by analyzing the average mass spectrum of each particle cluster extracted by ART-2a in different size ranges. In conclusion, BBB sample mostly consists of OC and EC containing particles, and a small fraction of K-rich particles in the size range of 0.2-0.5μm. In 0.5-1.0μm, BBB sample consists of EC, OC, K-rich and Al_Silicate containing particles; CBB sample consists of EC, ECOC containing particles, while Al_Silicate (including Al_Ca_Ti_Silicate, Al_Ti_Silicate, Al_Silicate) containing particles got higher fractions as size increase. The similarity of single particle mass spectrum signatures between two samples were studied by analyzing the dot product, results indicated that part of the single particle mass spectra of two samples in the same size range are similar, which bring challenge to the future source apportionment activity by using single particle aerosol mass spectrometer. Results of this study will provide physicochemical information of important sources which contribute to particle pollution, and will support source apportionment activities. Copyright © 2017. Published by Elsevier B.V.
Photon interaction studies using 241Am g-rays
NASA Astrophysics Data System (ADS)
Ramachandran, N.; Karunakaran Nair, K.; Abdullah, K. K.; Varier, K. M.
2006-09-01
We have carried out some photon interaction measurements using 59.54 keV γ-rays from a ^{241}Am source. These include γ attenuation studies as well as photoelectric absorption studies in various samples. The attenuation studies have been made using leaf and wood samples, samples like sand, sugar etc., which contain particles of varying sizes as well as pellets and aqueous solutions of rare earth compounds. In the case of the leaf and wood samples, we have used the γ-ray attenuation technique for the determination of the water content in fresh and dried samples. The variation of the attenuation coefficient with particle size has been investigated for sand and sugar samples. The attenuation studies as well as the photoelectric studies in the case of rare earth elements have been carried out on samples containing such elements whose K-absorption edge energies lie below and close to the γ-energy used. Suitable compounds of the rare earth elements have been chosen as mixture absorbers in these investigations. A narrow beam good geometry set-up was used for the attenuation measurements. A well-shielded scattering geometry was used for the photoelectric measurements. The mixture rule was invoked to extract the values of the mass attenuation coefficients for the elements from those of the corresponding compounds. The results are consistent with theoretical values derived from the XCOM package.
On the origin of nonlinear elasticity in disparate rocks
Riviere, Jacques Vincent; Shokouhi, Parisa; Guyer, Robert A.; ...
2015-03-31
Dynamic acousto-elastic (DAE) studies are performed on a set of 6 rock samples (four sandstones, one soapstone, and one granite). From these studies, at 20 strain levels 10 -7 < ϵ < 10 -5, four measures characterizing the nonlinear elastic response of each sample are found. Additionally, each sample is tested with nonlinear resonant ultrasonic spectroscopy (NRUS) and a fth measure of nonlinear elastic response is found. The ve measures of the nonlinear elastic response of the samples (approximately 3 x 6 x 20 x 5 numbers as each measurement is repeated 3 times) are subjected to careful analysis usingmore » model independent statistical methods, principal component analysis and fuzzy clustering. This analysis reveals di erences among the samples and di erences among the nonlinear measures. Four of the nonlinear measures are sensing much the same physical mechanism in the samples. The fth is seeing something di erent. This is the case for all samples. Although the same physical mechanisms (two) are operating in all samples there are distinctive features in the way the physical mechanisms present themselves from sample to sample. This suggests classi cation of the samples into two groups. The numbers in this study and the classi cation of the measures/samples constitute an empirical characterization of rock nonlinear elastic properties that can serve as a valuable testing ground for physically based theories that relate rock nonlinear elastic properties to microscopic elastic features.« less
Efficacy of adrenal venous sampling is increased by point of care cortisol analysis
Viste, Kristin; Grytaas, Marianne A; Jørstad, Melissa D; Jøssang, Dag E; Høyden, Eivind N; Fotland, Solveig S; Jensen, Dag K; Løvås, Kristian; Thordarson, Hrafnkell; Almås, Bjørg; Mellgren, Gunnar
2013-01-01
Primary aldosteronism (PA) is a common cause of secondary hypertension and is caused by unilateral or bilateral adrenal disease. Treatment options depend on whether the disease is lateralized or not, which is preferably evaluated with selective adrenal venous sampling (AVS). This procedure is technically challenging, and obtaining representative samples from the adrenal veins can prove difficult. Unsuccessful AVS procedures often require reexamination. Analysis of cortisol during the procedure may enhance the success rate. We invited 21 consecutive patients to participate in a study with intra-procedural point of care cortisol analysis. When this assay showed nonrepresentative sampling, new samples were drawn after redirection of the catheter. The study patients were compared using the 21 previous procedures. The intra-procedural cortisol assay increased the success rate from 10/21 patients in the historical cohort to 17/21 patients in the study group. In four of the 17 successful procedures, repeated samples needed to be drawn. Successful sampling at first attempt improved from the first seven to the last seven study patients. Point of care cortisol analysis during AVS improves success rate and reduces the need for reexaminations, in accordance with previous studies. Successful AVS is crucial when deciding which patients with PA will benefit from surgical treatment. PMID:24169597
Whitmore, Roy W; Chen, Wenlin
2013-12-04
The ability to infer human exposure to substances from drinking water using monitoring data helps determine and/or refine potential risks associated with drinking water consumption. We describe a survey sampling approach and its application to an atrazine groundwater monitoring study to adequately characterize upper exposure centiles and associated confidence intervals with predetermined precision. Study design and data analysis included sampling frame definition, sample stratification, sample size determination, allocation to strata, analysis weights, and weighted population estimates. Sampling frame encompassed 15 840 groundwater community water systems (CWS) in 21 states throughout the U. S. Median, and 95th percentile atrazine concentrations were 0.0022 and 0.024 ppb, respectively, for all CWS. Statistical estimates agreed with historical monitoring results, suggesting that the study design was adequate and robust. This methodology makes no assumptions regarding the occurrence distribution (e.g., lognormality); thus analyses based on the design-induced distribution provide the most robust basis for making inferences from the sample to target population.
Bouffard, Jeff; Bry, Jeff; Smith, Shamayne; Bry, Rhonda
2008-12-01
Much of the criminological literature testing rational choice theory has utilized hypothetical scenarios presented to university students. Although this research generally supports rational choice theory, a common criticism is that conclusions from these studies may not generalize to samples of actual offenders. This study proceeds to examine this issue in two steps. First, a traditional sample of university students is examined to determine how various costs and benefits relate to their hypothetical likelihood of offending. Then the same data collection procedures are employed with a somewhat different sample of younger, adjudicated, and institutionalized offenders to determine whether the conclusions drawn from the student sample generalize to this offender sample. Results generally suggest that the content and process of hypothetical criminal decision making differ in the sample of known offenders relative to the university students. Limitations of the current study, as well as suggestions for future research, are discussed.
Samusik, Nikolay; Wang, Xiaowei; Guan, Leying; Nolan, Garry P.
2017-01-01
Mass cytometry (CyTOF) has greatly expanded the capability of cytometry. It is now easy to generate multiple CyTOF samples in a single study, with each sample containing single-cell measurement on 50 markers for more than hundreds of thousands of cells. Current methods do not adequately address the issues concerning combining multiple samples for subpopulation discovery, and these issues can be quickly and dramatically amplified with increasing number of samples. To overcome this limitation, we developed Partition-Assisted Clustering and Multiple Alignments of Networks (PAC-MAN) for the fast automatic identification of cell populations in CyTOF data closely matching that of expert manual-discovery, and for alignments between subpopulations across samples to define dataset-level cellular states. PAC-MAN is computationally efficient, allowing the management of very large CyTOF datasets, which are increasingly common in clinical studies and cancer studies that monitor various tissue samples for each subject. PMID:29281633
Sampling Designs in Qualitative Research: Making the Sampling Process More Public
ERIC Educational Resources Information Center
Onwuegbuzie, Anthony J.; Leech, Nancy L.
2007-01-01
The purpose of this paper is to provide a typology of sampling designs for qualitative researchers. We introduce the following sampling strategies: (a) parallel sampling designs, which represent a body of sampling strategies that facilitate credible comparisons of two or more different subgroups that are extracted from the same levels of study;…
COMPARISON OF SAMPLING TECHNIQUES USED IN STUDYING LEPIDOPTERA POPULATION DYNAMICS
Four methods (light traps, foliage samples, canvas bands, and gypsy moth egg mass surveys) that are used to study the population dynamics of foliage-feeding Lepidoptera were compared for 10 species, including gypsy moth, Lymantria dispar L. Samples were collected weekly at 12 sit...
Jei, J Brintha; Mohan, Jayashree
2014-03-01
The periodontal health of abutment teeth and the durability of fixed partial denture depends on the marginal adaptation of the prosthesis. Any discrepancy in the marginal area leads to dissolution of luting agent and plaque accumulation. This study was done with the aim of evaluating the accuracy of marginal fit of four unit crown and bridge made up of Ni-Cr and Cr-Co alloys under induction and centrifugal casting. They were compared to cast fixed partial denture (FPD) and soldered FPD. For the purpose of this study a metal model was fabricated. A total of 40 samples (4-unit crown and bridge) were prepared in which 20 Cr-Co samples and 20 Ni-Cr samples were fabricated. Within these 20 samples of each group 10 samples were prepared by induction casting technique and other 10 samples with centrifugal casting technique. The cast FPD samples obtained were seated on the model and the samples were then measured with travelling microscope having precision of 0.001 cm. Sectioning of samples was done between the two pontics and measurements were made, then the soldering was made with torch soldering unit. The marginal discrepancy of soldered samples was measured and all findings were statistically analysed. The results revealed minimal marginal discrepancy with Cr-Co samples when compared to Ni-Cr samples done under induction casting technique. When compared to cast FPD samples, the soldered group showed reduced marginal discrepancy.
Page, Michael M; Taranto, Mario; Ramsay, Duncan; van Schie, Greg; Glendenning, Paul; Gillett, Melissa J; Vasikaran, Samuel D
2018-01-01
Objective Primary aldosteronism is a curable cause of hypertension which can be treated surgically or medically depending on the findings of adrenal vein sampling studies. Adrenal vein sampling studies are technically demanding with a high failure rate in many centres. The use of intraprocedural cortisol measurement could improve the success rates of adrenal vein sampling but may be impracticable due to cost and effects on procedural duration. Design Retrospective review of the results of adrenal vein sampling procedures since commencement of point-of-care cortisol measurement using a novel single-use semi-quantitative measuring device for cortisol, the adrenal vein sampling Accuracy Kit. Success rate and complications of adrenal vein sampling procedures before and after use of the adrenal vein sampling Accuracy Kit. Routine use of the adrenal vein sampling Accuracy Kit device for intraprocedural measurement of cortisol commenced in 2016. Results Technical success rate of adrenal vein sampling increased from 63% of 99 procedures to 90% of 48 procedures ( P = 0.0007) after implementation of the adrenal vein sampling Accuracy Kit. Failure of right adrenal vein cannulation was the main reason for an unsuccessful study. Radiation dose decreased from 34.2 Gy.cm 2 (interquartile range, 15.8-85.9) to 15.7 Gy.cm 2 (6.9-47.3) ( P = 0.009). No complications were noted, and implementation costs were minimal. Conclusions Point-of-care cortisol measurement during adrenal vein sampling improved cannulation success rates and reduced radiation exposure. The use of the adrenal vein sampling Accuracy Kit is now standard practice at our centre.
Martini, Valeria; Bernardi, Serena; Marelli, Priscilla; Cozzi, Marzia; Comazzi, Stefano
2018-06-01
Objectives Flow cytometry (FC) is becoming increasingly popular among veterinary oncologists for the diagnosis of lymphoma or leukaemia. It is accurate, fast and minimally invasive. Several studies of FC have been carried out in canine oncology and applied with great results, whereas there is limited knowledge and use of this technique in feline patients. This is mainly owing to the high prevalence of intra-abdominal lymphomas in this species and the difficulty associated with the diagnostic procedures needed to collect the sample. The purpose of the present study is to investigate whether any pre-analytical factor might affect the quality of suspected feline lymphoma samples for FC analysis. Methods Ninety-seven consecutive samples of suspected feline lymphoma were retrospectively selected from the authors' institution's FC database. The referring veterinarians were contacted and interviewed about several different variables, including signalment, appearance of the lesion, features of the sampling procedure and the experience of veterinarians performing the sampling. Statistical analyses were performed to assess the possible influence of these variables on the cellularity of the samples and the likelihood of it being finally processed for FC. Results Sample cellularity is a major factor in the likelihood of the sample being processed. Moreover, sample cellularity was significantly influenced by the needle size, with 21 G needles providing the highest cellularity. Notably, the sample cellularity and the likelihood of being processed did not vary between peripheral and intra-abdominal lesions. Approximately half of the cats required pharmacological restraint. Side effects were reported in one case only (transient swelling after peripheral lymph node sampling). Conclusions and relevance FC can be safely applied to cases of suspected feline lymphomas, including intra-abdominal lesions. A 21 G needle should be preferred for sampling. This study provides the basis for the increased use of this minimally invasive, fast and cost-effective technique in feline medicine.
Approaches to Recruiting 'Hard-To-Reach' Populations into Re-search: A Review of the Literature.
Shaghaghi, Abdolreza; Bhopal, Raj S; Sheikh, Aziz
2011-01-01
'Hard-to-reach' is a term used to describe those sub-groups of the population that may be difficult to reach or involve in research or public health programmes. Application of a single term to call these sub-sections of populations implies a homogeneity within distinct groups, which does not necessarily exist. Different sampling techniques were introduced so far to recruit hard-to-reach populations. In this article, we have reviewed a range of ap-proaches that have been used to widen participation in studies. We performed a Pubmed and Google search for relevant English language articles using the keywords and phrases: (hard-to-reach AND population* OR sampl*), (hidden AND population* OR sample*) and ("hard to reach" AND population* OR sample*) and a consul-tation of the retrieved articles' bibliographies to extract empirical evidence from publications that discussed or examined the use of sampling techniques to recruit hidden or hard-to-reach populations in health studies. Reviewing the literature has identified a range of techniques to recruit hard-to-reach populations, including snowball sampling, respondent-driven sampling (RDS), indigenous field worker sampling (IFWS), facility-based sampling (FBS), targeted sampling (TS), time-location (space) sampling (TLS), conventional cluster sampling (CCS) and capture re-capture sampling (CR). The degree of compliance with a study by a certain 'hard-to-reach' group de-pends on the characteristics of that group, recruitment technique used and the subject of inter-est. Irrespective of potential advantages or limitations of the recruitment techniques reviewed, their successful use depends mainly upon our knowledge about specific characteristics of the target populations. Thus in line with attempts to expand the current boundaries of our know-ledge about recruitment techniques in health studies and their applications in varying situa-tions, we should also focus on possibly all contributing factors which may have an impact on participation rate within a defined population group.
Andersson, Sonia; Belkić, Karen; Mints, Miriam; Östensson, Ellinor
2018-01-01
Self-sampling to test for high risk human papilloma virus (HPV) is becoming an increasingly important component of cervical cancer screening. The aim of this observational study is to examine how women treated for high-grade cervical intraepithelial neoplasia (CIN) view HPV self-sampling. Invited to participate in the present study were patients who had undergone treatment of high-grade CIN (grade 2 or higher) and were followed-up at 6-months at the Karolinska University Hospital, Stockholm. The participants were instructed as to how to perform HPV self-sampling. Thereafter, the participants completed a questionnaire about HPV self-sampling and other cervical cancer screening methods, as well as about self-perceived risk of cervical cancer without regular gynecologic follow-up and about specific knowledge regarding HPV, CIN and cervical cancer. Altogether 479 women enrolled in this study. The participation rate was 96.6%. Nearly 75% of the participants stated they would consider performing the HPV self-sampling prior to their next gynecologic follow-up. Confidence in HPV self-sampling was a significant independent predictor of willingness to perform HPV self-sampling. However, confidence in HPV self-sampling was significantly lower than confidence in Papanicolaou smears and in HPV testing with samples collected by health professionals. Higher specific knowledge about HPV, CIN and cervical cancer was also a significant independent predictor of willingness to perform HPV self-sampling, as was having travelled longer distance to attend gynecologic follow-up. Participants with lower income and without completed university education expressed significantly higher confidence in HPV self-sampling and lower confidence in Papanicolaou smears than the other women. To the best of our knowledge, this is the first study to examine the views of women treated for high-grade CIN vis-à-vis HPV self-sampling. The latter is an acceptable option for the vast majority of this cohort of women.
Reproducibility of urinary biomarkers in multiple 24-h urine samples.
Sun, Qi; Bertrand, Kimberly A; Franke, Adrian A; Rosner, Bernard; Curhan, Gary C; Willett, Walter C
2017-01-01
Limited knowledge regarding the reproducibility of biomarkers in 24-h urine samples has hindered the collection and use of the samples in epidemiologic studies. We aimed to evaluate the reproducibility of various markers in repeat 24-h urine samples. We calculated intraclass correlation coefficients (ICCs) of biomarkers measured in 24-h urine samples that were collected in 3168 participants in the NHS (Nurses' Health Study), NHSII (Nurses' Health Study II), and Health Professionals Follow-Up Study. In 742 women with 4 samples each collected over the course of 1 y, ICCs for sodium were 0.32 in the NHS and 0.34 in the NHSII. In 2439 men and women with 2 samples each collected over 1 wk to ≥1 mo, the ICCs ranged from 0.33 to 0.68 for sodium at various intervals between collections. The urinary excretion of potassium, calcium, magnesium, phosphate, sulfate, and other urinary markers showed generally higher reproducibility (ICCs >0.4). In 47 women with two 24-h urine samples, ICCs ranged from 0.15 (catechin) to 0.75 (enterolactone) for polyphenol metabolites. For phthalates, ICCs were generally ≤0.26 except for monobenzyl phthalate (ICC: 0.55), whereas the ICC was 0.39 for bisphenol A (BPA). We further estimated that, for the large majority of the biomarkers, the mean of three 24-h urine samples could provide a correlation of ≥0.8 with true long-term urinary excretion. These data suggest that the urinary excretion of various biomarkers, such as minerals, electrolytes, most polyphenols, and BPA, is reasonably reproducible in 24-h urine samples that are collected within a few days or ≤1 y. Our findings show that three 24-h samples are sufficient for the measurement of long-term exposure status in epidemiologic studies. © 2017 American Society for Nutrition.
Reproducibility of urinary biomarkers in multiple 24-h urine samples123
Sun, Qi; Bertrand, Kimberly A; Franke, Adrian A; Rosner, Bernard; Curhan, Gary C; Willett, Walter C
2017-01-01
Background: Limited knowledge regarding the reproducibility of biomarkers in 24-h urine samples has hindered the collection and use of the samples in epidemiologic studies. Objective: We aimed to evaluate the reproducibility of various markers in repeat 24-h urine samples. Design: We calculated intraclass correlation coefficients (ICCs) of biomarkers measured in 24-h urine samples that were collected in 3168 participants in the NHS (Nurses’ Health Study), NHSII (Nurses’ Health Study II), and Health Professionals Follow-Up Study. Results: In 742 women with 4 samples each collected over the course of 1 y, ICCs for sodium were 0.32 in the NHS and 0.34 in the NHSII. In 2439 men and women with 2 samples each collected over 1 wk to ≥1 mo, the ICCs ranged from 0.33 to 0.68 for sodium at various intervals between collections. The urinary excretion of potassium, calcium, magnesium, phosphate, sulfate, and other urinary markers showed generally higher reproducibility (ICCs >0.4). In 47 women with two 24-h urine samples, ICCs ranged from 0.15 (catechin) to 0.75 (enterolactone) for polyphenol metabolites. For phthalates, ICCs were generally ≤0.26 except for monobenzyl phthalate (ICC: 0.55), whereas the ICC was 0.39 for bisphenol A (BPA). We further estimated that, for the large majority of the biomarkers, the mean of three 24-h urine samples could provide a correlation of ≥0.8 with true long-term urinary excretion. Conclusions: These data suggest that the urinary excretion of various biomarkers, such as minerals, electrolytes, most polyphenols, and BPA, is reasonably reproducible in 24-h urine samples that are collected within a few days or ≤1 y. Our findings show that three 24-h samples are sufficient for the measurement of long-term exposure status in epidemiologic studies. PMID:28049663
CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF URINE SAMPLES (SOP-2.14)
This SOP describes the method for collecting urine samples from the study participants (children and their primary caregivers). Urine samples will be approximate 48-hr collections, collected as spot urine samples accumulated over the 48-hr sampling period. If the household or da...
Hatch, Stephani L.; Woodhead, Charlotte; Frissa, Souci; Fear, Nicola T.; Verdecchia, Maria; Stewart, Robert; Reichenberg, Abraham; Morgan, Craig; Bebbington, Paul; McManus, Sally; Brugha, Traolach; Kankulu, Bwalya; Clark, Jennifer L.; Gazard, Billy; Medcalf, Robert; Hotopf, Matthew
2012-01-01
Background Reliance on national figures may be underestimating the extent of mental ill health in urban communities. This study demonstrates the necessity for local information on common mental disorder (CMD) and substance use by comparing data from the South East London Community Health (SELCoH) study with those from a national study, the 2007 English Adult Psychiatric Morbidity Study (APMS). Methodology/Principal Findings Data were used from two cross-sectional surveys, 1698 men and women residing in south London and 7403 men and women in England. The main outcome, CMD, was indicated by a score of 12 or above on the Revised Clinical Interview Schedule. Secondary outcomes included hazardous alcohol use and illicit drug use. SELCoH sample prevalence estimates of CMD were nearly twice that of the APMS England sample estimates. There was a four-fold greater proportion of depressive episode in the SELCoH sample than the APMS sample. The prevalence of hazardous alcohol use was higher in the national sample. Illicit drug use in the past year was higher in the SELCoH sample, with cannabis and cocaine the illicit drugs reported most frequently in both samples. In comparisons of the SELCoH sample with the APMS England sample and the APMS sample from the Greater London area in combined datasets, these differences remained after adjusting for socio-demographic and socioeconomic indicators for all outcomes. Conclusions/Significance Local information for estimating the prevalence of CMD and substance use is essential for surveillance and service planning. There were similarities in the demographic and socioeconomic factors related to CMD and substance use across samples. PMID:23251330
Measuring the gut microbiome in birds: Comparison of faecal and cloacal sampling.
Videvall, Elin; Strandh, Maria; Engelbrecht, Anel; Cloete, Schalk; Cornwallis, Charlie K
2018-05-01
The gut microbiomes of birds and other animals are increasingly being studied in ecological and evolutionary contexts. Numerous studies on birds and reptiles have made inferences about gut microbiota using cloacal sampling; however, it is not known whether the bacterial community of the cloaca provides an accurate representation of the gut microbiome. We examined the accuracy with which cloacal swabs and faecal samples measure the microbiota in three different parts of the gastrointestinal tract (ileum, caecum, and colon) using a case study on juvenile ostriches, Struthio camelus, and high-throughput 16S rRNA sequencing. We found that faeces were significantly better than cloacal swabs in representing the bacterial community of the colon. Cloacal samples had a higher abundance of Gammaproteobacteria and fewer Clostridia relative to the gut and faecal samples. However, both faecal and cloacal samples were poor representatives of the microbial communities in the caecum and ileum. Furthermore, the accuracy of each sampling method in measuring the abundance of different bacterial taxa was highly variable: Bacteroidetes was the most highly correlated phylum between all three gut sections and both methods, whereas Actinobacteria, for example, was only strongly correlated between faecal and colon samples. Based on our results, we recommend sampling faeces, whenever possible, as this sample type provides the most accurate assessment of the colon microbiome. The fact that neither sampling technique accurately portrayed the bacterial community of the ileum nor the caecum illustrates the difficulty in noninvasively monitoring gut bacteria located further up in the gastrointestinal tract. These results have important implications for the interpretation of avian gut microbiome studies. © 2017 John Wiley & Sons Ltd.
Verdoodt, F; Jentschke, M; Hillemanns, P; Racey, C S; Snijders, P J F; Arbyn, M
2015-11-01
Population coverage for cervical cancer screening is an important determinant explaining differences in the incidence of cervical cancer between countries. Offering devices for self-sampling has the potential to increase participation of hard-to-reach women. A systematic review and meta-analysis were performed to evaluate the participation after an invitation including a self-sampling device (self-sampling arm) versus an invitation to have a sample taken by a health professional (control arm), sent to under-screened women. Sixteen randomised studies were found eligible. In an intention-to-treat analysis, the pooled participation in the self-sampling arm was 23.6% (95% confidence interval (CI)=20.2-27.3%), when self-sampling kits were sent by mail to all women, versus 10.3% (95% CI=6.2-15.2%) in the control arm (participation difference: 12.6% [95% CI=9.3-15.9]). When women had to opt-in to receive the self-sampling device, as used in three studies, the pooled participation was not higher in the self-sampling compared to the control arm (participation difference: 0.2% [95% CI=-4.5-4.9%]). An increased participation was observed in the self-sampling arm compared to the control arm, if self-sampling kits were sent directly to women at their home address. However, the size of the effect varied substantially among studies. Since participation was similar in both arms when women had to opt-in, future studies are warranted to discern opt-in scenarios that are most acceptable to women. Copyright © 2015 Elsevier Ltd. All rights reserved.
Adaptive sampling in behavioral surveys.
Thompson, S K
1997-01-01
Studies of populations such as drug users encounter difficulties because the members of the populations are rare, hidden, or hard to reach. Conventionally designed large-scale surveys detect relatively few members of the populations so that estimates of population characteristics have high uncertainty. Ethnographic studies, on the other hand, reach suitable numbers of individuals only through the use of link-tracing, chain referral, or snowball sampling procedures that often leave the investigators unable to make inferences from their sample to the hidden population as a whole. In adaptive sampling, the procedure for selecting people or other units to be in the sample depends on variables of interest observed during the survey, so the design adapts to the population as encountered. For example, when self-reported drug use is found among members of the sample, sampling effort may be increased in nearby areas. Types of adaptive sampling designs include ordinary sequential sampling, adaptive allocation in stratified sampling, adaptive cluster sampling, and optimal model-based designs. Graph sampling refers to situations with nodes (for example, people) connected by edges (such as social links or geographic proximity). An initial sample of nodes or edges is selected and edges are subsequently followed to bring other nodes into the sample. Graph sampling designs include network sampling, snowball sampling, link-tracing, chain referral, and adaptive cluster sampling. A graph sampling design is adaptive if the decision to include linked nodes depends on variables of interest observed on nodes already in the sample. Adjustment methods for nonsampling errors such as imperfect detection of drug users in the sample apply to adaptive as well as conventional designs.
PCR detection of Burkholderia multivorans in water and soil samples.
Peeters, Charlotte; Daenekindt, Stijn; Vandamme, Peter
2016-08-12
Although semi-selective growth media have been developed for the isolation of Burkholderia cepacia complex bacteria from the environment, thus far Burkholderia multivorans has rarely been isolated from such samples. Because environmental B. multivorans isolates mainly originate from water samples, we hypothesized that water rather than soil is its most likely environmental niche. The aim of the present study was to assess the occurrence of B. multivorans in water samples from Flanders (Belgium) using a fast, culture-independent PCR assay. A nested PCR approach was used to achieve high sensitivity, and specificity was confirmed by sequencing the resulting amplicons. B. multivorans was detected in 11 % of the water samples (n = 112) and 92 % of the soil samples (n = 25) tested. The percentage of false positives was higher for water samples compared to soil samples, showing that the presently available B. multivorans recA primers lack specificity when applied to the analysis of water samples. The results of the present study demonstrate that B. multivorans DNA is commonly present in soil samples and to a lesser extent in water samples in Flanders (Belgium).
Variance Estimation, Design Effects, and Sample Size Calculations for Respondent-Driven Sampling
2006-01-01
Hidden populations, such as injection drug users and sex workers, are central to a number of public health problems. However, because of the nature of these groups, it is difficult to collect accurate information about them, and this difficulty complicates disease prevention efforts. A recently developed statistical approach called respondent-driven sampling improves our ability to study hidden populations by allowing researchers to make unbiased estimates of the prevalence of certain traits in these populations. Yet, not enough is known about the sample-to-sample variability of these prevalence estimates. In this paper, we present a bootstrap method for constructing confidence intervals around respondent-driven sampling estimates and demonstrate in simulations that it outperforms the naive method currently in use. We also use simulations and real data to estimate the design effects for respondent-driven sampling in a number of situations. We conclude with practical advice about the power calculations that are needed to determine the appropriate sample size for a study using respondent-driven sampling. In general, we recommend a sample size twice as large as would be needed under simple random sampling. PMID:16937083
Groundwater quality in the Lower Hudson River Basin, New York, 2008
Nystrom, Elizabeth A.
2010-01-01
Water samples were collected from 32 production and domestic wells in the study area from August through November 2008 to characterize the groundwater quality. The study area, which covers 5,607 square miles, encompasses the part of the Lower Hudson River Basin that lies within New York plus the parts of the Housatonic, Hackensack, Bronx, and Saugatuck River Basins that are in New York. The study area is underlain by mainly clastic bedrock, predominantly shale, with carbonate and crystalline rock present locally. The bedrock is generally overlain by till, but surficial deposits of saturated sand and gravel are present in some areas. Of the 32 wells sampled, 16 were finished in sand and gravel deposits and 16 were finished in bedrock. The samples were collected and processed by standard U.S. Geological Survey procedures and were analyzed for 225 physiochemical properties and constituents, including major ions, nutrients, trace elements, radon-222, pesticides, and volatile organic compounds (VOCs); indicator bacteria were collected and analyzed by New York State Department of Health procedures. Water quality in the study area is generally good, but concentrations of some constituents exceeded current or proposed Federal or New York State primary or secondary drinking-water standards; the standards exceeded were color (2 samples), pH (6 samples), sodium (8 samples), fluoride (1 sample), aluminum (3 samples), arsenic (1 sample), iron (7 samples), manganese (14 samples), radon-222 (17 samples), tetrachloroethene (1 sample), and bacteria (7 samples). The pH of all samples was typically neutral or slightly basic (median 7.2); the median water temperature was 11.8 degrees C. The ions with the highest concentrations were bicarbonate [median 167 milligrams per liter (mg/L)] and calcium (median 38.2 mg/L). Groundwater in the study area ranged from very soft to very hard, but more samples were classified as very hard (181 mg/L as CaCO3 or more) than soft (60 mg/L as CaCO3 or less); the median hardness was 140 mg/L as CaCO3. The maximum concentration of nitrate plus nitrite was 2.38 mg/L as nitrogen, which did not exceed established drinking-water standards for nitrate plus nitrite (10 mg/L as nitrogen). The trace elements with the highest concentrations were strontium [median 189 micrograms per liter ((u or mu)g/L)] and barium (median 50.6 (u or mu)g/L). The highest radon-222 activities were in samples from crystalline bedrock wells [maximum 13,800 picocuries per liter (pCi/L)]. Seventeen samples had radon-222 activities that exceeded a proposed U.S. Environmental Protection Agency (USEPA) drinking-water standard of 300 pCi/L; activities in two samples exceeded a proposed alternative drinking-water standard of 4,000 pCi/L. Ten pesticides and pesticide degradates were detected among 14 samples at concentrations of 0.183 (u or mu)g/L or less; most were herbicides or their degradates. Eight VOCs were detected among six samples; these included solvents, gasoline components, and a trihalomethane. Total coliform bacteria were detected in seven samples; fecal coliform bacteria, including Escherichia coli, were detected in one sample.
A preliminary study of Mars rover/sample return missions
NASA Technical Reports Server (NTRS)
1987-01-01
The Solar System Exploration Committee (SSEC) of the NASA Advisory Council recommends that a Mars Sample Return mission be undertaken before the year 2000. Comprehensive studies of a Mars Sample Return mission have been ongoing since 1984. The initial focus of these studies was an integrated mission concept with the surface rover and sample return vehicle elements delivered to Mars on a single launch and landed together. This approach, to be carried out as a unilateral U.S. initiative, is still a high priority goal in an Augmented Program of exploration, as the SSEC recommendation clearly states. With this background of a well-understood mission concept, NASA decided to focus its 1986 study effort on a potential opportunity not previously examined; namely, a Mars Rover/Sample Return (MRSR) mission which would involve a significant aspect of international cooperation. As envisioned, responsibility for the various mission operations and hardware elements would be divided in a logical manner with clearly defined and acceptable interfaces. The U.S. and its international partner would carry out separately launched but coordinated missions with the overall goal of accomplishing in situ science and returning several kilograms of surface samples from Mars. Important considerations for implementation of such a plan are minimum technology transfer, maximum sharing of scientific results, and independent credibility of each mission role. Under the guidance and oversight of a Mars Exploration Strategy Advisory Group organized by NASA, a study team was formed in the fall of 1986 to develop a preliminary definition of a flight-separable, cooperative mission. The selected concept assumes that the U.S. would undertake the rover mission with its sample collection operations and our international partner would return the samples to Earth. Although the inverse of these roles is also possible, this study report focuses on the rover functions of MRSR because rover operations have not been studied in as much detail as the sample return functions of the mission.
Guerra Valero, Yarmarly C; Wallis, Steven C; Lipman, Jeffrey; Stove, Christophe; Roberts, Jason A; Parker, Suzanne L
2018-03-01
Conventional sampling techniques for clinical pharmacokinetic studies often require the removal of large blood volumes from patients. This can result in a physiological or emotional burden, particularly for neonates or pediatric patients. Antibiotic pharmacokinetic studies are typically performed on healthy adults or general ward patients. These may not account for alterations to a patient's pathophysiology and can lead to suboptimal treatment. Microsampling offers an important opportunity for clinical pharmacokinetic studies in vulnerable patient populations, where smaller sample volumes can be collected. This systematic review provides a description of currently available microsampling techniques and an overview of studies reporting the quantitation and validation of antibiotics using microsampling. A comparison of microsampling to conventional sampling in clinical studies is included.
Measuring eating disorder attitudes and behaviors: a reliability generalization study
2014-01-01
Background Although score reliability is a sample-dependent characteristic, researchers often only report reliability estimates from previous studies as justification for employing particular questionnaires in their research. The present study followed reliability generalization procedures to determine the mean score reliability of the Eating Disorder Inventory and its most commonly employed subscales (Drive for Thinness, Bulimia, and Body Dissatisfaction) and the Eating Attitudes Test as a way to better identify those characteristics that might impact score reliability. Methods Published studies that used these measures were coded based on their reporting of reliability information and additional study characteristics that might influence score reliability. Results Score reliability estimates were included in 26.15% of studies using the EDI and 36.28% of studies using the EAT. Mean Cronbach’s alphas for the EDI (total score = .91; subscales = .75 to .89), EAT-40 (total score = .81) and EAT-26 (total score = .86; subscales = .56 to .80) suggested variability in estimated internal consistency. Whereas some EDI subscales exhibited higher score reliability in clinical eating disorder samples than in nonclinical samples, other subscales did not exhibit these differences. Score reliability information for the EAT was primarily reported for nonclinical samples, making it difficult to characterize the effect of type of sample on these measures. However, there was a tendency for mean score reliability to be higher in the adult (vs. adolescent) samples and in female (vs. male) samples. Conclusions Overall, this study highlights the importance of assessing and reporting internal consistency during every test administration because reliability is affected by characteristics of the participants being examined. PMID:24764530
Groundwater quality in central New York, 2012
Reddy, James E.
2014-01-01
Water samples were collected from 14 production wells and 15 private wells in central New York from August through December 2012 in a study conducted by the U.S. Geological Survey in cooperation with the New York State Department of Environmental Conservation. The samples were analyzed to characterize the groundwater quality in unconsolidated and bedrock aquifers in this area. Fifteen of the wells are finished in sand-and-gravel aquifers, and 14 are finished in bedrock aquifers. Six of the 29 wells were sampled in a previous central New York study, which was conducted in 2007. Water samples from the 2012 study were analyzed for 147 physiochemical properties and constituents, including major ions, nutrients, trace elements, radionuclides, pesticides, volatile organic compounds, dissolved gases (argon, carbon dioxide, methane, nitrogen, oxygen), and indicator bacteria. Results of the water-quality analyses are presented in tabular form for individual wells, and summary statistics for specific constituents are presented by aquifer type. The results are compared with Federal and New York State drinking-water standards, which typically are identical. The results indicate that the groundwater generally is of acceptable quality, although for all of the wells sampled, at least one of the following constituents was detected at a concentration that exceeded current or proposed Federal or New York State drinking-water standards: color (2 samples), pH (7 samples), sodium (9 samples), chloride (2 samples), fluoride (2 samples), sulfate (2 samples), dissolved solids (8 samples), aluminum (4 samples), arsenic (1 sample), iron (9 samples), manganese (13 samples), radon-222 (13 samples), total coliform bacteria (6 samples), and heterotrophic bacteria (2 samples). Drinking-water standards for nitrate, nitrite, antimony, barium, beryllium, cadmium, chromium, copper, lead, mercury, selenium, silver, thallium, zinc, gross alpha radioactivity, uranium, fecal coliform, and Escherichia coliwere not exceeded in any of the samples collected. None of the pesticides or volatile organic compounds analyzed exceeded drinking-water standards. Methane was detected in 11 sand-and-gravel wells and 9 bedrock wells. Five of the 14 bedrock wells had water with methane concentrations approaching 10 mg/L; water in one bedrock well had 37 mg/L of methane.
Biostatistics Series Module 5: Determining Sample Size
Hazra, Avijit; Gogtay, Nithya
2016-01-01
Determining the appropriate sample size for a study, whatever be its type, is a fundamental aspect of biomedical research. An adequate sample ensures that the study will yield reliable information, regardless of whether the data ultimately suggests a clinically important difference between the interventions or elements being studied. The probability of Type 1 and Type 2 errors, the expected variance in the sample and the effect size are the essential determinants of sample size in interventional studies. Any method for deriving a conclusion from experimental data carries with it some risk of drawing a false conclusion. Two types of false conclusion may occur, called Type 1 and Type 2 errors, whose probabilities are denoted by the symbols σ and β. A Type 1 error occurs when one concludes that a difference exists between the groups being compared when, in reality, it does not. This is akin to a false positive result. A Type 2 error occurs when one concludes that difference does not exist when, in reality, a difference does exist, and it is equal to or larger than the effect size defined by the alternative to the null hypothesis. This may be viewed as a false negative result. When considering the risk of Type 2 error, it is more intuitive to think in terms of power of the study or (1 − β). Power denotes the probability of detecting a difference when a difference does exist between the groups being compared. Smaller α or larger power will increase sample size. Conventional acceptable values for power and α are 80% or above and 5% or below, respectively, when calculating sample size. Increasing variance in the sample tends to increase the sample size required to achieve a given power level. The effect size is the smallest clinically important difference that is sought to be detected and, rather than statistical convention, is a matter of past experience and clinical judgment. Larger samples are required if smaller differences are to be detected. Although the principles are long known, historically, sample size determination has been difficult, because of relatively complex mathematical considerations and numerous different formulas. However, of late, there has been remarkable improvement in the availability, capability, and user-friendliness of power and sample size determination software. Many can execute routines for determination of sample size and power for a wide variety of research designs and statistical tests. With the drudgery of mathematical calculation gone, researchers must now concentrate on determining appropriate sample size and achieving these targets, so that study conclusions can be accepted as meaningful. PMID:27688437
Small sample sizes in the study of ontogenetic allometry; implications for palaeobiology
Vavrek, Matthew J.
2015-01-01
Quantitative morphometric analyses, particularly ontogenetic allometry, are common methods used in quantifying shape, and changes therein, in both extinct and extant organisms. Due to incompleteness and the potential for restricted sample sizes in the fossil record, palaeobiological analyses of allometry may encounter higher rates of error. Differences in sample size between fossil and extant studies and any resulting effects on allometric analyses have not been thoroughly investigated, and a logical lower threshold to sample size is not clear. Here we show that studies based on fossil datasets have smaller sample sizes than those based on extant taxa. A similar pattern between vertebrates and invertebrates indicates this is not a problem unique to either group, but common to both. We investigate the relationship between sample size, ontogenetic allometric relationship and statistical power using an empirical dataset of skull measurements of modern Alligator mississippiensis. Across a variety of subsampling techniques, used to simulate different taphonomic and/or sampling effects, smaller sample sizes gave less reliable and more variable results, often with the result that allometric relationships will go undetected due to Type II error (failure to reject the null hypothesis). This may result in a false impression of fewer instances of positive/negative allometric growth in fossils compared to living organisms. These limitations are not restricted to fossil data and are equally applicable to allometric analyses of rare extant taxa. No mathematically derived minimum sample size for ontogenetic allometric studies is found; rather results of isometry (but not necessarily allometry) should not be viewed with confidence at small sample sizes. PMID:25780770
[Anaerobic bacteria isolated from patients with suspected anaerobic infections].
Ercis, Serpil; Tunçkanat, Ferda; Hasçelik, Gülşen
2005-10-01
The study involved 394 clinical samples sent to the Clinical Microbiology Laboratory of Hacettepe University Adult Hospital between January 1997 and May 2004 for anaerobic cultivation. Since multiple cultures from the same clinical samples of the same patient were excluded, the study was carried on 367 samples. The anaerobic cultures were performed in anaerobic jar using AnaeroGen kits (Oxoid, Basingstoke, U.K.) or GENbox (bioMérieux, Lyon, France). The isolates were identified by both classical methods and "BBL Crystal System" (Becton Dickinson, U.S.A.). While no growth was detected in 120 (32.7%) of the clinical samples studied, in 144 samples (39.2%) only aerobes, in 28 (7.6%) only anaerobes and in 75 (20.5%) of the samples both aerobes and anaerobes were isolated. The number of the anaerobic isolates was 217 from 103 samples with anaerobic growth. Of these 103 samples 15 showed single bacterial growth whereas in 88 samples multiple bacterial isolates were detected. Anaerobic isolates consisted of 92 Gram negative bacilli (Bacteroides spp. 50, Prevotella spp. 14, Porphyromonas spp. 10, Fusobacterium spp. 7, Tisierella spp. 2, unidentified 9), 57 Gram positive bacilli (Clostridium spp.17, Propionibacterium spp. 16, Lactobacillus spp. 8, Actinomyces spp. 5, Eubacterium spp. 2, Bifidobacterium adolescentis 1, Mobiluncus mulieris 1, unidentified nonspore forming rods 7), 61 Gram positive cocci (anaerobic cocci 44, microaerophilic cocci 17), and 7 Gram negative cocci (Veillonella spp.). In conclusion, in the samples studied with prediagnosis of anaerobic infection, Bacteroides spp. (23%) were the most common bacteria followed by anaerobic Gram positive cocci (20.3%) and Clostridium spp (7.8%).
Kent, Robert; Belitz, Kenneth; Fram, Miranda S.
2014-01-01
The Priority Basin Project (PBP) of the Groundwater Ambient Monitoring and Assessment (GAMA) Program was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The GAMA-PBP began sampling, primarily public supply wells in May 2004. By the end of February 2006, seven (of what would eventually be 35) study units had been sampled over a wide area of the State. Selected wells in these first seven study units were resampled for water quality from August 2007 to November 2008 as part of an assessment of temporal trends in water quality by the GAMA-PBP. The initial sampling was designed to provide a spatially unbiased assessment of the quality of raw groundwater used for public water supplies within the seven study units. In the 7 study units, 462 wells were selected by using a spatially distributed, randomized grid-based method to provide statistical representation of the study area. Wells selected this way are referred to as grid wells or status wells. Approximately 3 years after the initial sampling, 55 of these previously sampled status wells (approximately 10 percent in each study unit) were randomly selected for resampling. The seven resampled study units, the total number of status wells sampled for each study unit, and the number of these wells resampled for trends are as follows, in chronological order of sampling: San Diego Drainages (53 status wells, 7 trend wells), North San Francisco Bay (84, 10), Northern San Joaquin Basin (51, 5), Southern Sacramento Valley (67, 7), San Fernando–San Gabriel (35, 6), Monterey Bay and Salinas Valley Basins (91, 11), and Southeast San Joaquin Valley (83, 9). The groundwater samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOCs], pesticides, and pesticide degradates), constituents of special interest (perchlorate, N-nitrosodimethylamine [NDMA], and 1,2,3-trichloropropane [1,2,3-TCP]), and naturally-occurring inorganic constituents (nutrients, major and minor ions, and trace elements). Naturally-occurring isotopes (tritium, carbon-14, and stable isotopes of hydrogen and oxygen in water) also were measured to help identify processes affecting groundwater quality and the sources and ages of the sampled groundwater. Nearly 300 constituents and water-quality indicators were investigated. Quality-control samples (blanks, replicates, and samples for matrix spikes) were collected at 24 percent of the 55 status wells resampled for trends, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a noticeable source of bias in the data for the groundwater samples. Differences between replicate samples were mostly within acceptable ranges, indicating acceptably low variability in analytical results. Matrix-spike recoveries were within the acceptable range (70 to 130 percent) for 75 percent of the compounds for which matrix spikes were collected. This study did not attempt to evaluate the quality of water delivered to consumers. After withdrawal, groundwater typically is treated, disinfected, and blended with other waters to maintain acceptable water quality. The benchmarks used in this report apply to treated water that is served to the consumer, not to untreated groundwater. To provide some context for the results, however, concentrations of constituents measured in these groundwater samples were compared with benchmarks established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH). Comparisons between data collected for this study and benchmarks for drinking water are for illustrative purposes only and are not indicative of compliance or non-compliance with those benchmarks. Most constituents that were detected in groundwater samples from the trend wells were found at concentrations less than drinking-water benchmarks. Four VOCs—trichloroethene, tetrachloroethene, 1,2-dibromo-3-chloropropane, and methyl tert-butyl ether—were detected in one or more wells at concentrations greater than their health-based benchmarks, and six VOCs were detected in at least 10 percent of the samples during initial sampling or resampling of the trend wells. No pesticides were detected at concentrations near or greater than their health-based benchmarks. Three pesticide constituents—atrazine, deethylatrazine, and simazine—were detected in more than 10 percent of the trend-well samples during both sampling periods. Perchlorate, a constituent of special interest, was detected more frequently, and at greater concentrations during resampling than during initial sampling, but this may be due to a change in analytical method between the sampling periods, rather than to a change in groundwater quality. Another constituent of special interest, 1,2,3-TCP, was also detected more frequently during resampling than during initial sampling, but this pattern also may not reflect a change in groundwater quality. Samples from several of the wells where 1,2,3-TCP was detected by low-concentration-level analysis during resampling were not analyzed for 1,2,3-TCP using a low-level method during initial sampling. Most detections of nutrients and trace elements in samples from trend wells were less than health-based benchmarks during both sampling periods. Exceptions include nitrate, arsenic, boron, and vanadium, all detected at concentrations greater than their health-based benchmarks in at least one well during both sampling periods, and molybdenum, detected at concentrations greater than its health-based benchmark during resampling only. The isotopic ratios of oxygen and hydrogen in water and tritium and carbon-14 activities generally changed little between sampling periods, suggesting that the predominant sources and ages of groundwater in most trend wells were consistent between the sampling periods.
Characterization and Beneficiation Studies of a Low Grade Bauxite Ore
NASA Astrophysics Data System (ADS)
Rao, D. S.; Das, B.
2014-10-01
A low grade bauxite sample of central India was thoroughly characterized with the help of stereomicroscope, reflected light microscope and electron microscope using QEMSCAN. A few hand picked samples were collected from different places of the mine and were subjected to geochemical characterization studies. The geochemical studies indicated that most of the samples contain high silica and low alumina, except a few which are high grade. Mineralogically the samples consist of bauxite (gibbsite and boehmite), ferruginous mineral phases (goethite and hematite), clay and silicate (quartz), and titanium bearing minerals like rutile and ilmenite. Majority of the gibbsite, boehmite and gibbsitic oolites contain clay, quartz and iron and titanium mineral phases within the sample as inclusions. The sample on an average contains 39.1 % Al2O3 and 12.3 % SiO2, and 20.08 % of Fe2O3. Beneficiation techniques like size classification, sorting, scrubbing, hydrocyclone and magnetic separation were employed to reduce the silica content suitable for Bayer process. The studies indicated that, 50 % by weight with 41 % Al2O3 containing less than 5 % SiO2 could be achieved. The finer sized sample after physical beneficiation still contains high silica due to complex mineralogical associations.
Stupples, A
1980-01-01
The pressure to establish the Dunedin (New Zealand) Male Advice Clinic came from members of the Psychology Department of the University of Otago as a result of a study of attitudes towards the use and purchase of contraceptives among the local young people. The study findings and the suggestions made for the establishment of a male advice center are summarized. 3 samples were studied: a university sample (N=80); a sample of high school students (N=243); and a general population sample (N=70). The males in all samples were questioned regarding the process of purchasing contraceptives. The study findings indicated that embarrassment functioned as an impediment to obtaining contraceptive supplies. 76% of the university sample, 36% of the school sample, and 57% of the general population thought that males needed advice in choosing condoms. The male advice center would be open to anyone but designed specifically to cater to young men who anticipate or are already engaged in sexual intercourse. Services available would include contraceptive advice, contraceptive supplies, and sexual advice and counseling. Initial interest in the Dunedin Male Advice Clinic was considerable, but the question remained as to whether the group for whom the clinic was intended was really reached.
Microbial Communities in Pre-Columbian Coprolites
Santiago-Rodriguez, Tasha M.; Narganes-Storde, Yvonne M.; Chanlatte, Luis; Crespo-Torres, Edwin; Toranzos, Gary A.; Jimenez-Flores, Rafael; Hamrick, Alice; Cano, Raul J.
2013-01-01
The study of coprolites from earlier cultures represents a great opportunity to study an “unaltered” composition of the intestinal microbiota. To test this, pre-Columbian coprolites from two cultures, the Huecoid and Saladoid, were evaluated for the presence of DNA, proteins and lipids by cytochemical staining, human and/or dog-specific Bacteroides spp. by PCR, as well as bacteria, fungi and archaea using Terminal Restriction Fragment analyses. DNA, proteins and lipids, and human-specific Bacteroides DNA were detected in all coprolites. Multidimensional scaling analyses resulted in spatial arrangements of microbial profiles by culture, further supported by cluster analysis and ANOSIM. Differences between the microbial communities were positively correlated with culture, and SIMPER analysis indicated 68.8% dissimilarity between the Huecoid and Saladoid. Proteobacteria, Bacteroidetes and methanogens were found in all coprolite samples. Propionebacteria, Shewanella and lactic acid bacteria dominated in the Huecoid samples, while Acidobacteria, and peptococci were dominant in Saladoid samples. Yeasts, including Candida albicans and Crypotococcus spp. were found in all samples. Basidiomycetes were the most notable fungi in Huecoid samples while Ascomycetes predominated in Saladoid samples, suggesting differences in dietary habits. Our study provides an approach for the study of the microbial communities of coprolite samples from various cultures. PMID:23755194
Sample size calculation for a proof of concept study.
Yin, Yin
2002-05-01
Sample size calculation is vital for a confirmatory clinical trial since the regulatory agencies require the probability of making Type I error to be significantly small, usually less than 0.05 or 0.025. However, the importance of the sample size calculation for studies conducted by a pharmaceutical company for internal decision making, e.g., a proof of concept (PoC) study, has not received enough attention. This article introduces a Bayesian method that identifies the information required for planning a PoC and the process of sample size calculation. The results will be presented in terms of the relationships between the regulatory requirements, the probability of reaching the regulatory requirements, the goalpost for PoC, and the sample size used for PoC.
Mars Rover Sample Return mission
NASA Technical Reports Server (NTRS)
Bourke, Roger D.; Kwok, Johnny H.; Friedlander, Alan
1989-01-01
To gain a detailed understanding of the character of the planet Mars, it is necessary to send vehicle to the surface and return selected samples for intensive study in earth laboratories. Toward that end, studies have been underway for several years to determine the technically feasible means for exploring the surface and returning selected samples. This paper describes several MRSR mission concepts that have emerged from the most recent studies.
ERIC Educational Resources Information Center
Akin Kösterelioglu, Meltem; Kösterelioglu, Ilker
2015-01-01
This study aims to identify the effects of high school students' perceptions of school life quality on their academic motivation levels. The study was conducted on a sample of high school students (n = 2371) in Amasya Province in the fall semester of 2013-2014 academic year. Study sample was selected with the help of cluster sampling method. Data…
Quality of Life and Emotional Intelligence in a Sample of Kuwait University Students
ERIC Educational Resources Information Center
Al-Huwailah, Amthal
2017-01-01
The purpose of the study is to describe of the nature of the relationship between quality of Life and Emotional Intelligence in a sample of Kuwait University students, as well as to identify the differences between males and females in the variables of the study, The study sample consists of 400 students from the University of Kuwait, (200) males…
ERIC Educational Resources Information Center
Neel, John H.; Stallings, William M.
An influential statistics test recommends a Levene text for homogeneity of variance. A recent note suggests that Levene's test is upwardly biased for small samples. Another report shows inflated Alpha estimates and low power. Neither study utilized more than two sample sizes. This Monte Carlo study involved sampling from a normal population for…
Batra, Renu; Kataria, Pratik; Kapoor, Sonali
2016-10-01
Scientifically and clinically there has been lot of development in the field of aesthetic dentistry. However, there is limited or restricted information regarding the color stability of flowable composite materials. The aim of this study was to evaluate the spectrophotometric color stability of three different flowable composite materials with respect to three different pH of saliva. The study included 90 different samples. Thirty samples in each composite group; (Group A: G-aenial universal flo; Group B: Z 350 XT flowable; Group C: Esthet x flow). All samples from each group were immersed in distilled water for 24 hours. Total color difference (ΔE) was recorded for each sample. After this 10 samples from each group were respectively immersed in 6.5, 7 and 7.5 pH of artificial saliva. All samples were kept in dark room for seven days and then ΔE for each sample was recorded and was compared to previous recorded ΔE for the same sample. Maximum color change was seen irrespective of material in 6.5 pH of saliva. G-aenial universal flo showed least change irrespective of pH of saliva. Thus, the present study reveals that acidic pH level affects the coloration of composite resins by affecting the surface integrity and as reported in previous studies, various coloring agents in beverages and other dietary components assists the process due to absorption of these coloring substances into the resin matrix.
Optimal design in pediatric pharmacokinetic and pharmacodynamic clinical studies.
Roberts, Jessica K; Stockmann, Chris; Balch, Alfred; Yu, Tian; Ward, Robert M; Spigarelli, Michael G; Sherwin, Catherine M T
2015-03-01
It is not trivial to conduct clinical trials with pediatric participants. Ethical, logistical, and financial considerations add to the complexity of pediatric studies. Optimal design theory allows investigators the opportunity to apply mathematical optimization algorithms to define how to structure their data collection to answer focused research questions. These techniques can be used to determine an optimal sample size, optimal sample times, and the number of samples required for pharmacokinetic and pharmacodynamic studies. The aim of this review is to demonstrate how to determine optimal sample size, optimal sample times, and the number of samples required from each patient by presenting specific examples using optimal design tools. Additionally, this review aims to discuss the relative usefulness of sparse vs rich data. This review is intended to educate the clinician, as well as the basic research scientist, whom plan on conducting a pharmacokinetic/pharmacodynamic clinical trial in pediatric patients. © 2015 John Wiley & Sons Ltd.
How Large Should a Statistical Sample Be?
ERIC Educational Resources Information Center
Menil, Violeta C.; Ye, Ruili
2012-01-01
This study serves as a teaching aid for teachers of introductory statistics. The aim of this study was limited to determining various sample sizes when estimating population proportion. Tables on sample sizes were generated using a C[superscript ++] program, which depends on population size, degree of precision or error level, and confidence…
NHEXAS PHASE I ARIZONA STUDY--METALS IN DERMAL WIPES ANALYTICAL RESULTS
The Metals in Dermal Wipes data set contains analytical results for measurements of up to 11 metals in 179 dermal wipe samples over 179 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. The sampling per...
Preschoolers' Mathematics Skills and Behavior: Analysis of a National Sample
ERIC Educational Resources Information Center
Dobbs-Oates, Jennifer; Robinson, Chanele
2012-01-01
This study investigated the association between children's mathematical skills and their behavior in the prekindergarten year in a national sample of children attending center-based child care. The sample consisted of approximately 5,400 preschoolers in center-based care from the Early Childhood Longitudinal Study--Birth Cohort. Children's math…
NHEXAS PHASE I ARIZONA STUDY--METALS IN URINE ANALYTICAL RESULTS
The Metals in Urine data set contains analytical results for measurements of up to 6 metals in 176 urine samples over 176 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. The sample consists of the fir...
Adaptive sampling in research on risk-related behaviors.
Thompson, Steven K; Collins, Linda M
2002-11-01
This article introduces adaptive sampling designs to substance use researchers. Adaptive sampling is particularly useful when the population of interest is rare, unevenly distributed, hidden, or hard to reach. Examples of such populations are injection drug users, individuals at high risk for HIV/AIDS, and young adolescents who are nicotine dependent. In conventional sampling, the sampling design is based entirely on a priori information, and is fixed before the study begins. By contrast, in adaptive sampling, the sampling design adapts based on observations made during the survey; for example, drug users may be asked to refer other drug users to the researcher. In the present article several adaptive sampling designs are discussed. Link-tracing designs such as snowball sampling, random walk methods, and network sampling are described, along with adaptive allocation and adaptive cluster sampling. It is stressed that special estimation procedures taking the sampling design into account are needed when adaptive sampling has been used. These procedures yield estimates that are considerably better than conventional estimates. For rare and clustered populations adaptive designs can give substantial gains in efficiency over conventional designs, and for hidden populations link-tracing and other adaptive procedures may provide the only practical way to obtain a sample large enough for the study objectives.
NASA Astrophysics Data System (ADS)
Carnes, Corrie Leigh
The goal of this research was to synthesize, characterize and study the chemical properties of nanocrystalline metal oxides. Nanocrystalline (NC) ZnO, CuO, NiO, Al2O3, and the binary Al2O 3/MgO and ZnO/CuO were prepared through modified sol gel methods. These NC metal oxides were studied in comparison to the commercial (CM) metal oxides. The samples were characterized by XRD, TGA, FTIR, BET, and TEM. The NC samples were all accompanied by a significant increase in surface area and decrease in crystallite size. Several chemical reactions were studied to compare the NC samples to the CM samples. One of the reactions involved a high temperature reaction between carbon tetrachloride and the oxide to form carbon dioxide and the corresponding metal chloride. A similar high temperature reaction was conducted between the metal oxide and hydrogen sulfide to form water and the corresponding metal sulfide. A room temperature gas phase adsorption was studied where SO2 was adsorbed onto the oxide. A liquid phase adsorption conducted at room temperature was the destructive adsorption of paraoxon (a toxic insecticide). In all reactions the NC samples exhibited greater activity, destroying or adsorbing a larger amount of the toxins compared to the CM samples. To better study surface area effects catalytic reactions were also studied. The catalysis of methanol was studied over the nanocrystalline ZnO, CuO, NiO, and ZnO/CuO samples in comparison to their commercial counterparts. In most cases the NC samples proved to be more active catalysts, having higher percent conversions and turnover numbers. A second catalytic reaction was also studied, this reaction was investigated to look at the support effects. The catalysis of cyclopropane to propane was studied over Pt and Co catalysts. These catalysts were supported onto NC and CM alumina by impregnation. By observing differences in the catalytic behavior, support effects have become apparent.
Factors affecting blood sample haemolysis: a cross-sectional study.
Barnard, Ed B G; Potter, David L; Ayling, Ruth M; Higginson, Ian; Bailey, Andrew G; Smith, Jason E
2016-04-01
To determine the effect of blood sampling through an intravenous catheter compared with a needle in Emergency Department blood sampling. We undertook a prospective, cross-sectional study in a UK university teaching hospital Emergency Department. A convenience sample of 985 patients who required blood sampling via venepuncture was collected. A total of 844 complete sets of data were analysed. The median age was 63 years, and 57% of patients were male. The primary outcome measure was the incidence of haemolysis in blood samples obtained via a needle compared with samples obtained via an intravenous catheter. Secondary outcome measures defined the effect on sample haemolysis of the side of the patient the sample was obtained from, the anatomical location of sampling, the perceived difficulty in obtaining the sample, the order of sample tubes collected, estimated tourniquet time and bench time. Data were analysed with logistic regression, and expressed as odds ratios (95% confidence intervals; P-values). Blood samples obtained through an intravenous catheter were more likely to be haemolysed than those obtained via a needle, odds ratio 5.63 (95% confidence interval 2.49-12.73; P<0.001). Blood sampling via an intravenous catheter was significantly associated with an increase in the likelihood of sample haemolysis compared with sampling with a needle. Wherever practicable, blood samples should be obtained via a needle in preference to an intravenous catheter. Future research should include both an economic evaluation, and staff and patient satisfaction of separating blood sampling and intravenous catheter placement.
Cheng, Jun; He, Jun; Liu, Huaping; Cai, Hao; Hong, Guini; Zhang, Jiahui; Li, Na; Ao, Lu; Guo, Zheng
2017-01-01
Formalin-fixed paraffin-embedded (FFPE) samples represent a valuable resource for clinical researches. However, FFPE samples are usually considered an unreliable source for gene expression analysis due to the partial RNA degradation. In this study, through comparing gene expression profiles between FFPE samples and paired fresh-frozen (FF) samples for three cancer types, we firstly showed that expression measurements of thousands of genes had at least two-fold change in FFPE samples compared with paired FF samples. Therefore, for a transcriptional signature based on risk scores summarized from the expression levels of the signature genes, the risk score thresholds trained from FFPE (or FF) samples could not be applied to FF (or FFPE) samples. On the other hand, we found that more than 90% of the relative expression orderings (REOs) of gene pairs in the FF samples were maintained in their paired FFPE samples and largely unaffected by the storage time. The result suggested that the REOs of gene pairs were highly robust against partial RNA degradation in FFPE samples. Finally, as a case study, we developed a REOs-based signature to distinguish liver cirrhosis from hepatocellular carcinoma (HCC) using FFPE samples. The signature was validated in four datasets of FFPE samples and eight datasets of FF samples. In conclusion, the valuable FFPE samples can be fully exploited to identify REOs-based diagnostic and prognostic signatures which could be robustly applicable to both FF samples and FFPE samples with degraded RNA. PMID:28036264
De Jong, G D; Hoback, W W
2006-06-01
Carrion insect succession studies have historically used repeated sampling of single or a few carcasses to produce data, either weighing the carcasses, removing a qualitative subsample of the fauna present, or both, on every visit over the course of decomposition and succession. This study, conducted in a set of related experimental hypotheses with two trials in a single season, investigated the effect that repeated sampling has on insect succession, determined by the number of taxa collected on each visit and by community composition. Each trial lasted at least 21 days, with daily visits on the first 14 days. Rat carcasses used in this study were all placed in the field on the same day, but then either sampled qualitatively on every visit (similar to most succession studies) or ignored until a given day of succession, when they were sampled qualitatively (a subsample) and then destructively sampled in their entirety. Carcasses sampled on every visit were in two groups: those from which only a sample of the fauna was taken and those from which a sample of fauna was taken and the carcass was weighed for biomass determination. Of the carcasses visited only once, the number of taxa in subsamples was compared to the actual number of taxa present when the carcass was destructively sampled to determine if the subsamples adequately represented the total carcass fauna. Data from the qualitative subsamples of those carcasses visited only once were also compared to data collected from carcasses that were sampled on every visit to investigate the effect of the repeated sampling. A total of 39 taxa were collected from carcasses during the study and the component taxa are discussed individually in relation to their role in succession. Number of taxa differed on only one visit between the qualitative subsamples and the actual number of taxa present, primarily because the organisms missed by the qualitative sampling were cryptic (hidden deep within body cavities) or rare (only represented by very few specimens). There were no differences discovered between number of taxa in qualitative subsamples from carcasses sampled repeatedly (with or without biomass determinations) and those sampled only a single time. Community composition differed considerably in later stages of decomposition, with disparate communities due primarily to small numbers of rare taxa. These results indicate that the methods used historically for community composition determination in experimental forensic entomology are generally adequate.
Nowlan, G.A.; Ficklin, Walter H.; Dover, Robert A.
1985-01-01
This report presents results of geochemical studies carried out in June and July of 1982 in the Buffalo Peaks Wilderness Study Area, Colo. (see index map). Samples of water were collected from 84 streams and 18 springs draining the study area. Tabulations of the analyses and a sample locality map are in Ficklin and others (1984). The geochemistry of stream sediments and panned concentrates of the study area is in Nowlan and Gerstel (1985). The geology of the study area and vicinity is in Hedlund (1985). The mineral resource potential of the study area is described in Hedlund and others (1983). This report (1) assists in the assessment of the mineral resource potential of the Buffalo Peaks Wilderness Study Area; and (2) compares analyses of water samples with analyses of stream-sediment and panned-concentrate samples (Nowlan and Gerstel, 1985).
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR METALS IN SPIKE SAMPLES
The Metals in Spike Samples data set contains the analytical results of measurements of up to 11 metals in 38 control samples (spikes) from 18 households. Measurements were made in spiked samples of dust, food, beverages, blood, urine, and dermal wipe residue. Spiked samples we...
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR METALS IN REPLICATE SAMPLES
The Metals in Replicate Samples data set contains the analytical results of measurements of up to 27 metals in 133 replicate (duplicate) samples from 62 households. Measurements were made in samples of soil, blood, tap water, and drinking water. Duplicate samples for a small pe...
Evaluating fungal contamination indoors is complicated because of the many different sampling methods utilized. In this study, fungal contamination was evaluated using five sampling methods and four matrices for results. The five sampling methods were a 48 hour indoor air sample ...
NHEXAS PHASE I REGION 5 STUDY--QA ANALYTICAL RESULTS FOR VOCS IN REPLICATES
This data set includes analytical results for measurements of VOCs in 204 duplicate (replicate) samples. Measurements were made for up to 23 VOCs in samples of air, water, and blood. Duplicate samples (samples collected along with or next to the original samples) were collected t...
NHEXAS PHASE I REGION 5 STUDY--QA ANALYTICAL RESULTS FOR METALS IN REPLICATES
This data set includes analytical results for measurements of metals in 490 duplicate (replicate) samples and for particles in 130 duplicate samples. Measurements were made for up to 11 metals in samples of air, dust, water, blood, and urine. Duplicate samples (samples collected ...
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR PESTICIDE METABOLITES IN SPIKE SAMPLES
The Pesticide Metabolites in Spike Samples data set contains the analytical results of measurements of up to 4 pesticide metabolites in 3 control samples (spikes) from 3 households. Measurements were made in spiked samples of urine. Spiked samples were used to assess recovery o...
40 CFR 761.323 - Sample preparation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Remediation Waste Samples § 761.323 Sample preparation. (a) The comparison study requires analysis of a minimum of 10 samples weighing at least 300 grams each. Samples of PCB remediation waste used in the... PCB remediation waste at the cleanup site, or must be the same kind of material as that waste. For...
Understanding the Sampling Distribution and the Central Limit Theorem.
ERIC Educational Resources Information Center
Lewis, Charla P.
The sampling distribution is a common source of misuse and misunderstanding in the study of statistics. The sampling distribution, underlying distribution, and the Central Limit Theorem are all interconnected in defining and explaining the proper use of the sampling distribution of various statistics. The sampling distribution of a statistic is…
Confocal Raman studies in determining crystalline nature of PECVD grown Si nanowires
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahmed, Nafis; Bhargav, P. Balaji; Ramasamy, P.
2015-06-24
Silicon nanowires of diameter ∼200 nm and length of 2-4 µm are grown in the plasma enhanced chemical vapour deposition technique using nanoclustered Au catalyst assisted vapour-liquid-solid process. The crystallinity in the as-grown and annealed samples is studied using confocal Raman spectroscopic studies. Amorphous phase is formed in the as-grown samples. Structural studies using high resolution transmission electron microscopy confirm the polycrystalline nature in the annealed sample.
Gürsoy, Nafia Canan; Yakupoğulları, Yusuf; Tekerekoğlu, Mehmet Sait; Otlu, Barış
2016-04-01
Rapid and accurate detection of active tuberculosis (TB) cases is one of the most important goal of tuberculosis control programme. For this purpose, new methods are being developed to isolate, serotype and determine the drug resistance of the agent. Xpert MTB/RIF test (CepheidGeneXpert® System, USA) that has been recently developed, is a real-time polymerase chain reaction-based method which detects Mycobacterium tuberculosis complex and resistance of the strain to rifampicin (RIF) from the clinical sample directly within a couple of hours. However, there are not sufficient data about the performance of that test for extrapulmonary samples and pulmonary samples other than sputum. The aims of this study were to investigate the sensitivity, specificity, positive and negative predictive values of Xpert MTB/RIF test in detection of M. tuberculosis and the performance in the determination of rifampicin resistance of the isolates from pulmonary and extrapulmonary clinical samples. A total of 2160 clinical samples, in which 1141 (52.8%) were pulmonary and 1019 (47.2%) were extrapulmonary samples, sent to our laboratory between July 2013 to December 2014, were included in the study. Sixty seven of the evaluated samples (3.1%) were positive with microscopy (acid-fast stain; AFS), 116 samples (5.1%) were positive with culture and 98 samples (4.5%) were positive with Xpert MTB/RIF test. When the culture was considered as the reference method, the sensitivity and specificity of Xpert MTB/RIF test were determined as 73.3% and 99.3%, respectively for all samples; 77.5% and 99.5%, respectively for pulmonary samples and 63.9% and 99.2%, respectively for extrapulmonary samples. Among AFS positive samples, the sensitivity was 100% and specificity was 66.7%; whereas among AFS negative samples those values were 40.4% and 99.4%, respectively. Among all the samples involved in the study, RIF resistance was determined only in three samples with Xpert MTB/ RIF test and that was also proved phenotypically (100% concordance). According to mycobacterial culture results, positive and negative predictive values of Xpert MTB/RIF test were determined as 86.7% and 98.5%, respectively for all samples. Those were determined as 92.5% and 98.3%, respectively for extrapulmonary samples and were determined as 74.2 and 98.7%, respectively for pulmonary samples. According to the results obtained in our study, sensitivity of Xpert MTB/RIF test for extrapulmonary samples was found to be at moderate level; sensitivity of the test was found to be decreased especially in AFS negative samples with less bacilli load. Nonetheless, specificity of Xpert MTB/RIF test to the agent in all samples was found to be extremely high. In our study, although RIF-resistant strains were detected in few of the samples, Xpert MTB/ RIF test could differentiate all resistant and sensitive strains. Additionally, detection of M. tuberculosis and RIF resistance in our laboratory takes approximately 20.96 days with culture, this period decreases to a couple of hours with Xpert MTB/RIF test. Because of the advantages such as being practical, rapid and requiring minimal safety measures, it was concluded that Xpert MTB/RIF test may contribute to rapid diagnosis of TB also in extrapulmonary samples, with the confirmation of culture method.
Mecozzi, M; Amici, M; Romanelli, G; Pietrantonio, E; Deluca, A
2002-07-19
This paper reports an analytical procedure based on ultrasound to extract lipids in marine mucilage samples. The experimental conditions of the ultrasound procedure (solvent and time) were identified by a FT-IR study performed on different standard samples of lipids and of a standard humic sample, before and after the sonication treatment. This study showed that diethyl ether was a more suitable solvent than methanol for the ultrasonic extraction of lipids from environmental samples because it allowed to minimize the possible oxidative modifications of lipids due to the acoustic cavitation phenomena. The optimized conditions were applied to the extraction of total lipid amount in marine mucilage samples and TLC-flame ionization detection analysis was used to identify the relevant lipid sub-fractions present in samples.
Bell, Richard W.; Joseph, Robert L.; Freiwald, David A.
1996-01-01
Historical pesticide data from 1970-90 were compiled for 140 surface-water, 92 ground-water, 55 streambed-sediment, and 120 biological-tissue sampling sites within the Ozark Plateaus National Water-Quality Assessment Program study unit. Surface-water, bed-sediment, and biological-tissue sites have drainage basins predominantly in the Springfield and Salem Plateaus; ground-water sites are predominantly located in the Osage Plains and Mississippi Alluvial Plain. Many sites were sampled only once or twice during this period. A large percentage of the samples were collected in the mid-1970's and early 1980's for surface water, 1990 for ground water, the late 1980's for surface water, 1990 for ground water, the late 1980's for bed sediment, and the early 1980's for biological tissue. Pesticide use was approximately 4.2 million pounds per year of active ingredients from 1982-85 in the study unit and was generally greatest in the Springfield and Salem Plateaus pasturelands and in the Osage Plains and Mississippi Alluvial Plain cropland areas. The most frequently applied pesticide in the study unit was 2,4-D. Alachlor was the second most applied pesticide. Corn, pasture, rice, sorghum, and soybeans received approximately 90 percent of the pesticides applied within the study unit. The highest pesticide application rate per acre occurred on these crops in the Osage Plains and Mississippi Alluvial Plain. Pastureland was the predominant crop type in 50 of the 94 counties in the study unit. Toxaphene, the pesticide having the most number of detections in surface water, was found in 17 of 866 samples from 5 of 112 sites. Concentrations ranged from 0.1 to 6.0 micrograms per liter. Six other pesticides or pesticide metabolites were detected in 12 or more surface-water samples: DDE, dieldrin, DDT, aldrin, 2,4-D, and lindane. The maximum concentration for these pesticides was less than 1.0 micrograms per liter. Atrazine, the pesticide having the most number of detections in ground water, was found in 15 of 95 samples from 15 of 79 wells with concentrations ranging from 0.1 to 8.2 micrograms per liter. Metolachlor, alachlor, and prometon were detected more than once with maximum concentrations less than 1.0 micrograms per liter, except for prometon (2.4 micrograms per liter). Chlordane was the pesticide having the most number of detections in bed sediment and biological tissue. Chlordane was detected in 12 of 73 samples from 10 of 45 bed-sediment sites with concentrations ranging from 2.0 to 240 micrograms per kilogram. In biological tissue, chlordane was found in 93 of 151 samples from 39 of 53 sites with concentrations ranging from 0.009 to 8.6 milligrams per kilogram. Other pesticides or pesticide metabolites detected more than once in bed sediment include DDT, DDD, p,p'-DDE, DDE, and hexachlorobenzene and in biological tissue include DDT, p,p'-DDE, and hexachlorobenzene. Quality criteria or standards have been established for 15 of the pesticides detected in the study unit. For surface-water samples, the drinking water maximum contaminant level for alachlor was exceeded in one sample from one site in 1982. For ground-water samples, the drinking water maximum contaminant level for atrazine was exceeded in four samples from four wells in 1990. For biological-tissue samples collected during the years 1982-89, the fish tissue action levels for chlordane (19 sites; 26 samples), heptachlor epoxide (3 sites; 3 samples), p,p'-DDE (2 sites; 2 samples), dieldrin (2 sites, 2 samples), and mirex (1 site; 1 sample) were exceeded. For bed-sediment samples, quality criteria or standards were not exceeded for any pesticide. Pesticides do not pose any widespread or persistent problems in the study unit, based on the limited number of samples that exceeded quality criteria and standards.
Isolation of Acanthamoeba Spp. from Drinking Waters in Several Hospitals of Iran
Bagheri, HR; Shafiei, R; Shafiei, F; Sajjadi, SA
2010-01-01
Background Acanthamoeba is an opportunistic amphizoic protozoan found in different water sources including swimming pool as well as in sewage. The aim of this study was to investigate the prevalence of Acanthamoeba in tap-water samples in Iran. Method In this descriptive cross-sectional study, 94 samples of cold and warm tap-water were collected from different wards of hospitals in 13 cities of Iran in 2007–2008. Free residual chlorine, pH, and temperature of samples were measured. After filtration through multipore nylon membrane, samples were cultured on non-nutrient agar. Then we investigated existence of Acanthamoeba by reverse contrast phase microscope. Results Acanthamoeba was found in 45 samples (48%). Thirty-four and 11 positive samples were collected from cold and warm tap water, respectively. The samples belonged to the category of 20–30°C temperature with 0–2 ppm free residual chlorine and pH 6–7.4 showed the most coincidence to the positive cases. The greatest proportion of positive samples was obtained from Mashhad hospitals, while all samples collected from Arak and Semnan hospitals were negative. Conclusion considering the results of this study and the pathogenic role of this protozoan on patients with immunodeficiency, as well as capability of this microorganism in carrying other pathogens such as Legionella, further studies are needed. What is more important, potable water in hospitals should follow the procedure of treatment and sanitation, in order to prevent the relevant nosocomial infections. PMID:22347240
Melting behavior and phase relations of lunar samples. [Apollo 12 rock samples
NASA Technical Reports Server (NTRS)
Hays, J. F.
1975-01-01
Cooling rate studies of 12002 were conducted and the results interpreted in terms of the crystallization history of this rock and certain other picritic Apollo 12 samples. Calculations of liquid densities and viscosities during crystallization, crystal settling velocities, and heat loss by the parent rock body are discussed, as are petrographic studies of other Apollo 12 samples. The process of magmatic differentiation that must have accompanied the early melting and chemical fractionation of the moon's outer layers was investigated. The source of regions of both high- and low-titanium mare basalts were also studied.
Methods of human body odor sampling: the effect of freezing.
Lenochova, Pavlina; Roberts, S Craig; Havlicek, Jan
2009-02-01
Body odor sampling is an essential tool in human chemical ecology research. However, methodologies of individual studies vary widely in terms of sampling material, length of sampling, and sample processing. Although these differences might have a critical impact on results obtained, almost no studies test validity of current methods. Here, we focused on the effect of freezing samples between collection and use in experiments involving body odor perception. In 2 experiments, we tested whether axillary odors were perceived differently by raters when presented fresh or having been frozen and whether several freeze-thaw cycles affected sample quality. In the first experiment, samples were frozen for 2 weeks, 1 month, or 4 months. We found no differences in ratings of pleasantness, attractiveness, or masculinity between fresh and frozen samples. Similarly, almost no differences between repeatedly thawed and fresh samples were found. We found some variations in intensity; however, this was unrelated to length of storage. The second experiment tested differences between fresh samples and those frozen for 6 months. Again no differences in subjective ratings were observed. These results suggest that freezing has no significant effect on perceived odor hedonicity and that samples can be reliably used after storage for relatively long periods.
Zhu, Shanyou; Zhang, Hailong; Liu, Ronggao; Cao, Yun; Zhang, Guixin
2014-01-01
Sampling designs are commonly used to estimate deforestation over large areas, but comparisons between different sampling strategies are required. Using PRODES deforestation data as a reference, deforestation in the state of Mato Grosso in Brazil from 2005 to 2006 is evaluated using Landsat imagery and a nearly synchronous MODIS dataset. The MODIS-derived deforestation is used to assist in sampling and extrapolation. Three sampling designs are compared according to the estimated deforestation of the entire study area based on simple extrapolation and linear regression models. The results show that stratified sampling for strata construction and sample allocation using the MODIS-derived deforestation hotspots provided more precise estimations than simple random and systematic sampling. Moreover, the relationship between the MODIS-derived and TM-derived deforestation provides a precise estimate of the total deforestation area as well as the distribution of deforestation in each block.
NASA Technical Reports Server (NTRS)
Zeigler, Ryan A.
2014-01-01
An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of a PET is to characterize and classify the returned samples, making this information available to the general research community who can then conduct more in-depth studies on the samples. A PET strives to minimize the impact their work has on the sample suite, which often limits the PET work to largely visual measurements and observations like optical microscopy. More modern techniques can also be utilized by future PET to nondestructively characterize astromaterials in a more rigorous way. Here we present our recent analyses of Apollo samples 14321 and 14305 by micro-CT and micro-XRF (respectively), assess the potential for discovery of "new" Apollo samples for scientific study, and evaluate the usefulness of these techniques in future PET efforts.
In vivo microsampling to capture the elusive exposome
NASA Astrophysics Data System (ADS)
Bessonneau, Vincent; Ings, Jennifer; McMaster, Mark; Smith, Richard; Bragg, Leslie; Servos, Mark; Pawliszyn, Janusz
2017-03-01
Loss and/or degradation of small molecules during sampling, sample transportation and storage can adversely impact biological interpretation of metabolomics data. In this study, we performed in vivo sampling using solid-phase microextraction (SPME) in combination with non-targeted liquid chromatography and high-resolution tandem mass spectrometry (LC-MS/MS) to capture the fish tissue exposome using molecular networking analysis, and the results were contrasted with molecular differences obtained with ex vivo SPME sampling. Based on 494 MS/MS spectra comparisons, we demonstrated that in vivo SPME sampling provided better extraction and stabilization of highly reactive molecules, such as 1-oleoyl-sn-glycero-3-phosphocholine and 1-palmitoleoyl-glycero-3-phosphocholine, from fish tissue samples. This sampling approach, that minimizes sample handling and preparation, offers the opportunity to perform longitudinal monitoring of the exposome in biological systems and improve the reliability of exposure-measurement in exposome-wide association studies.
Chapin, Thomas
2015-01-01
Hand-collected grab samples are the most common water sampling method but using grab sampling to monitor temporally variable aquatic processes such as diel metal cycling or episodic events is rarely feasible or cost-effective. Currently available automated samplers are a proven, widely used technology and typically collect up to 24 samples during a deployment. However, these automated samplers are not well suited for long-term sampling in remote areas or in freezing conditions. There is a critical need for low-cost, long-duration, high-frequency water sampling technology to improve our understanding of the geochemical response to temporally variable processes. This review article will examine recent developments in automated water sampler technology and utilize selected field data from acid mine drainage studies to illustrate the utility of high-frequency, long-duration water sampling.
Zhu, Shanyou; Zhang, Hailong; Liu, Ronggao; Cao, Yun; Zhang, Guixin
2014-01-01
Sampling designs are commonly used to estimate deforestation over large areas, but comparisons between different sampling strategies are required. Using PRODES deforestation data as a reference, deforestation in the state of Mato Grosso in Brazil from 2005 to 2006 is evaluated using Landsat imagery and a nearly synchronous MODIS dataset. The MODIS-derived deforestation is used to assist in sampling and extrapolation. Three sampling designs are compared according to the estimated deforestation of the entire study area based on simple extrapolation and linear regression models. The results show that stratified sampling for strata construction and sample allocation using the MODIS-derived deforestation hotspots provided more precise estimations than simple random and systematic sampling. Moreover, the relationship between the MODIS-derived and TM-derived deforestation provides a precise estimate of the total deforestation area as well as the distribution of deforestation in each block. PMID:25258742
In vivo microsampling to capture the elusive exposome
Bessonneau, Vincent; Ings, Jennifer; McMaster, Mark; Smith, Richard; Bragg, Leslie; Servos, Mark; Pawliszyn, Janusz
2017-01-01
Loss and/or degradation of small molecules during sampling, sample transportation and storage can adversely impact biological interpretation of metabolomics data. In this study, we performed in vivo sampling using solid-phase microextraction (SPME) in combination with non-targeted liquid chromatography and high-resolution tandem mass spectrometry (LC-MS/MS) to capture the fish tissue exposome using molecular networking analysis, and the results were contrasted with molecular differences obtained with ex vivo SPME sampling. Based on 494 MS/MS spectra comparisons, we demonstrated that in vivo SPME sampling provided better extraction and stabilization of highly reactive molecules, such as 1-oleoyl-sn-glycero-3-phosphocholine and 1-palmitoleoyl-glycero-3-phosphocholine, from fish tissue samples. This sampling approach, that minimizes sample handling and preparation, offers the opportunity to perform longitudinal monitoring of the exposome in biological systems and improve the reliability of exposure-measurement in exposome-wide association studies. PMID:28266605
Bartsch, L.A.; Richardson, W.B.; Naimo, T.J.
1998-01-01
Estimation of benthic macroinvertebrate populations over large spatial scales is difficult due to the high variability in abundance and the cost of sample processing and taxonomic analysis. To determine a cost-effective, statistically powerful sample design, we conducted an exploratory study of the spatial variation of benthic macroinvertebrates in a 37 km reach of the Upper Mississippi River. We sampled benthos at 36 sites within each of two strata, contiguous backwater and channel border. Three standard ponar (525 cm(2)) grab samples were obtained at each site ('Original Design'). Analysis of variance and sampling cost of strata-wide estimates for abundance of Oligochaeta, Chironomidae, and total invertebrates showed that only one ponar sample per site ('Reduced Design') yielded essentially the same abundance estimates as the Original Design, while reducing the overall cost by 63%. A posteriori statistical power analysis (alpha = 0.05, beta = 0.20) on the Reduced Design estimated that at least 18 sites per stratum were needed to detect differences in mean abundance between contiguous backwater and channel border areas for Oligochaeta, Chironomidae, and total invertebrates. Statistical power was nearly identical for the three taxonomic groups. The abundances of several taxa of concern (e.g., Hexagenia mayflies and Musculium fingernail clams) were too spatially variable to estimate power with our method. Resampling simulations indicated that to achieve adequate sampling precision for Oligochaeta, at least 36 sample sites per stratum would be required, whereas a sampling precision of 0.2 would not be attained with any sample size for Hexagenia in channel border areas, or Chironomidae and Musculium in both strata given the variance structure of the original samples. Community-wide diversity indices (Brillouin and 1-Simpsons) increased as sample area per site increased. The backwater area had higher diversity than the channel border area. The number of sampling sites required to sample benthic macroinvertebrates during our sampling period depended on the study objective and ranged from 18 to more than 40 sites per stratum. No single sampling regime would efficiently and adequately sample all components of the macroinvertebrate community.
Gierke, Lioba; Binder, Nadine; Heckmann, Mark; Odağ, Özen; Leiser, Anne
2018-01-01
Introduction Intercultural competence (IC) is an important skill to be gained from higher education. However, it remains unclear what IC means to students and what factors might influence their definitions of IC. The aim of the current study was to qualitatively assess how students at one higher education institution in the USA define IC and to quantitatively test for relationships among IC components and various demographic characteristics, including intercultural experience and study context. A further aim was to descriptively compare the IC definitions from the US sample with the definitions obtained from another sample of university students in Germany. Materials and methods A purposive sample of n = 93 undergraduate, second semester students at Dickinson College, USA, participated in the study by completing an online questionnaire. The qualitative data were content-analyzed to define the dimensions of IC. The quantitative data were cluster-analyzed to assess the multivariate relationships among the IC components and the demographic characteristics of the sample. Results The most important dimensions of IC were Knowledge, External Outcomes (interaction, communication), and Attitudes (respect, tolerance) according to the US sample. The most frequently chosen dimensions of IC differed between both samples: Knowledge was chosen by the sample in the USA while External Outcomes was chosen by the sample in Germany. Relative to the US sample, significantly more students chose Attitudes, External Outcomes, and Intrapersonal Skills in the sample in Germany. The relationships among IC components and demographic characteristics were only weak in the US sample. A person with IC was rated as Open-minded and Respectful by students who lived predominantly in the USA or Tolerant and Curious by those who lived outside the USA for at least six months. Discussion The current results suggest that students residing in two countries (USA or Germany) define IC using similar dimensions. However, IC definitions may depend on the intercultural experience and the current global discourse. Longitudinal studies with representative samples are required to assess how IC definitions change over time. PMID:29698525
Terré, M; Castells, L; Fàbregas, F; Bach, A
2013-08-01
The objective of this study was to compare rumen samples from young dairy calves obtained via a stomach tube (ST) or a ruminal cannula (RC). Five male Holstein calves (46±4.0 kg of body weight and 11±4.9 d of age) were ruminally cannulated at 15 d of age. Calves received 4 L/d of a commercial milk replacer (25% crude protein and 19.2% fat) at 12.5% dry matter, and were provided concentrate and chopped oats hay ad libitum throughout the study (56 d). In total, 29 paired rumen samples were obtained weekly throughout the study in most of the calves by each extraction method. These samples were used to determine pH and volatile fatty acids (VFA) concentration, and to quantify Prevotella ruminicola and Streptococcus bovis by quantitative PCR. Furthermore, a denaturing gradient gel electrophoresis was performed on rumen samples harvested during wk 8 of the study to determine the degree of similarity between rumen bacteria communities. Rumen pH was 0.30 units greater in ST compared with RC samples. Furthermore, total VFA concentrations were greater in RC than in ST samples. However, when analyzing the proportion of each VFA by ANOVA, no differences were found between the sampling methods. The quantification of S. bovis and P. ruminicola was similar in both extraction methods, and values obtained using different methods were highly correlated (R(2)=0.89 and 0.98 for S. bovis and P. ruminicola, respectively). Fingerprinting analysis showed similar bacteria band profiles between samples obtained from the same calves using different extraction methods. In conclusion, when comparing rumen parameters obtained using different sampling techniques, it is recommended that VFA profiles be used rather than total VFA concentrations, as total VFA concentrations are more affected by the method of collection. Furthermore, although comparisons of pH across studies should be avoided when samples are not obtained using the same sampling method, the comparison of fingerprinting of a bacteria community or a specific rumen bacterium is valid. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Circulating tumoral cells lack circadian-rhythm in hospitalized metastasic breast cancer patients.
García-Sáenz, José Angel; Martín, Miguel; Maestro, Marisa; Vidaurreta, Marta; Veganzones, Silvia; Villalobos, Laura; Rodríguez-Lajusticia, Laura; Rafael, Sara; Sanz-Casla, María Teresa; Casado, Antonio; Sastre, Javier; Arroyo, Manuel; Díaz-Rubio, Eduardo
2006-11-01
The relationship between breast cancer and circadian rhythm variation has been extensively studied. Increased breast tumorigenesis has been reported in melatonin-suppressed experimental models and in observational studies. Circulating Tumor Cells (CTC) circadian- rhythm may optimize the timing of therapies. This is a prospective experimental study to ascertain the day-time and night-time CTC levels in hospitalized metastasic breast cancer (MBC) patients. CTC are isolated and enumerated from a 08:00 AM and 08:00 PM blood collections. 23 MBC and 23 healthy volunteers entered the study. 69 samples were collected (23 samples at 08:00 AM and 23 samples at 08:00 PM from MBC; 23 samples from healthy volunteers). Results from two patients were rejected due to sample processing errors. No CTC were isolated from healthy-volunteers. No-differences between daytime and night-time CTC were observed. Therefore, we could not ascertain CTC circadian-rhythm in hospitalized metastasic breast cancer patients.
A study of atmospheric mixing of trace gases by aerial sampling with a multi-rotor drone
NASA Astrophysics Data System (ADS)
Chang, Chih-Chung; Chang, Chih-Yuan; Wang, Jia-Lin; Lin, Ming-Ren; Ou-Yang, Chang-Feng; Pan, Hsiang-Hsu; Chen, Yen-Chen
2018-07-01
We exploited a novel sampling vehicle, a multi-rotor drone carrying a remote-controlled whole air sampling device, to collect aerial samples with high sample integrity and preservation conditions. An array of 106 volatile organic compounds (VOCs), CO, CH4, and CO2 were analyzed and compared between the aerial samples (300-m height) and the ground-level samples in pairs to inspect for vertical mixing of the trace gases at a coastal site under three different meteorological conditions of local circulation, frontal passage, and high-pressure peripheral circulation. A rather homogeneous composition was observed for the sample pairs immediately after the frontal passage, indicating a well-mixed condition below 300 m. In contrast, inhomogeneous mixing was observed for the sample pairs under the other two conditions (local circulation and high-pressure peripheral circulation), suggesting different layers of air masses. Furthermore, information of unique source markers, composition profiles, and lifetimes of compounds were used to differentiate the origins of the air masses aloft and at the surface to substantiate the observed inhomogeneity. The study demonstrates that, with the availability of the near-surface aerial sampling coupling with in-laboratory analysis, detailed compositions of trace gases can now be readily obtained with superior data quality. Based on the distinctive chemical compositions, the sources, transport, and atmospheric mixing of the airborne pollutants in the near-surface atmosphere can be better studied and understood.
Alay, Asli; Usta, Taner A; Ozay, Pinar; Karadugan, Ozgur; Ates, Ugur
2014-05-01
The objective of this study was to compare classical blind endometrial tissue sampling with hysteroscopic biopsy sampling following methylene blue dyeing in premenopausal and postmenopausal patients with abnormal uterine bleeding. A prospective case-control study was carried out in the Office Hysteroscopy Unit. Fifty-four patients with complaints of abnormal uterine bleeding were evaluated. Data of 38 patients were included in the statistical analysis. Three groups were compared by examining samples obtained through hysteroscopic biopsy before and after methylene blue dyeing, and classical blind endometrial tissue sampling. First, uterine cavity was evaluated with office hysteroscopy. Methylene blue dye was administered through the hysteroscopic inlet. Tissue samples were obtained from stained and non-stained areas. Blind endometrial sampling was performed in the same patients immediately after the hysteroscopy procedure. The results of hysteroscopic biopsy from methylene blue stained and non-stained areas and blind biopsy were compared. No statistically significant differences were determined in the comparison of biopsy samples obtained from methylene-blue stained, non-stained areas and blind biopsy (P > 0.05). We suggest that chromohysteroscopy is not superior to endometrial sampling in cases of abnormal uterine bleeding. Further studies with greater sample sizes should be performed to assess the validity of routine use of endometrial dyeing. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.
Dhasarathan, P; Theriappan, P; Ashokraja, C
2010-03-01
Microbial diversity of soil and water samples collected from pyrochemicals exposed areas of Virdhunagar district (Tamil Nadu, India) was studied. Soil and water samples from cultivable area, waste land and city area of the same region were also studied for a comparative acount. There is a remarkable reduction in total heterotrophic bacterial population (THB) in pyrochemicals exposed soil and water samples (42 × 10(4) CFU/g and 5.6 × 10(4) CFU/ml respectively), compared to the THB of cultivable area soil and water samples (98 × 10(7) CFU/g and 38.6 × 10(7) CFU/ml). The generic composition the THB of the pyrochemicals exposed samples too exhibited considerable change compared to other samples. Pseudomonas sp. was the predominant one (41.6%) followed by Achromobacter sp. (25%) in pyrochemical exposed soil and Pseudomonas sp. was the predominant one (25%) in pyrochemical exposed water samples followed by Bacillus sp. (25%) and Micrococcus sp. (16.6%). It was observed that Cornybacterium sp. and Micrococcus sp. were absent completely in pyrochemical exposed soil and Achromobacter sp. was missing in the pyrochemical exposed water samples, which were present in the other samples. The outcome of this study clearly demonstrates that pollutants such as chemicals used in pyrotechniques affect the microbial biodiversity and suitable measures have to be taken to control the pollution level and to save biodiversity.
Simple, Defensible Sample Sizes Based on Cost Efficiency
Bacchetti, Peter; McCulloch, Charles E.; Segal, Mark R.
2009-01-01
Summary The conventional approach of choosing sample size to provide 80% or greater power ignores the cost implications of different sample size choices. Costs, however, are often impossible for investigators and funders to ignore in actual practice. Here, we propose and justify a new approach for choosing sample size based on cost efficiency, the ratio of a study’s projected scientific and/or practical value to its total cost. By showing that a study’s projected value exhibits diminishing marginal returns as a function of increasing sample size for a wide variety of definitions of study value, we are able to develop two simple choices that can be defended as more cost efficient than any larger sample size. The first is to choose the sample size that minimizes the average cost per subject. The second is to choose sample size to minimize total cost divided by the square root of sample size. This latter method is theoretically more justifiable for innovative studies, but also performs reasonably well and has some justification in other cases. For example, if projected study value is assumed to be proportional to power at a specific alternative and total cost is a linear function of sample size, then this approach is guaranteed either to produce more than 90% power or to be more cost efficient than any sample size that does. These methods are easy to implement, based on reliable inputs, and well justified, so they should be regarded as acceptable alternatives to current conventional approaches. PMID:18482055
Hageman, Philip L.; Todd, Andrew S.; Smith, Kathleen S.; DeWitt, Ed; Zeigler, Mathew P.
2013-01-01
Scientists from the U.S. Geological Survey are studying the relationship between watershed lithology and stream-water chemistry. As part of this effort, 60 stream-water samples and 43 corresponding stream-sediment samples were collected in 2010 and 2011 from locations in Colorado and New Mexico. Sample sites were selected from small to midsize watersheds composed of a high percentage of one rock type or geologic unit. Stream-water and stream-sediment samples were collected, processed, preserved, and analyzed in a consistent manner. This report releases geochemical data for this phase of the study.
Capillary absorption spectrometer and process for isotopic analysis of small samples
Alexander, M. Lizabeth; Kelly, James F.; Sams, Robert L.; Moran, James J.; Newburn, Matthew K.; Blake, Thomas A.
2016-03-29
A capillary absorption spectrometer and process are described that provide highly sensitive and accurate stable absorption measurements of analytes in a sample gas that may include isotopologues of carbon and oxygen obtained from gas and biological samples. It further provides isotopic images of microbial communities that allow tracking of nutrients at the single cell level. It further targets naturally occurring variations in carbon and oxygen isotopes that avoids need for expensive isotopically labeled mixtures which allows study of samples taken from the field without modification. The method also permits sampling in vivo permitting real-time ambient studies of microbial communities.
Capillary absorption spectrometer and process for isotopic analysis of small samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alexander, M. Lizabeth; Kelly, James F.; Sams, Robert L.
A capillary absorption spectrometer and process are described that provide highly sensitive and accurate stable absorption measurements of analytes in a sample gas that may include isotopologues of carbon and oxygen obtained from gas and biological samples. It further provides isotopic images of microbial communities that allow tracking of nutrients at the single cell level. It further targets naturally occurring variations in carbon and oxygen isotopes that avoids need for expensive isotopically labeled mixtures which allows study of samples taken from the field without modification. The process also permits sampling in vivo permitting real-time ambient studies of microbial communities.
Tarsitano, Elvira; Greco, Grazia; Decaro, Nicola; Nicassio, Francesco; Lucente, Maria Stella; Buonavoglia, Canio; Tempesta, Maria
2010-11-01
Few studies have been conducted in Italy to quantify the potential risk associated with dynamics and distribution of pathogens in urban settings. The aim of this study was to acquire data on the environmental faecal contamination in urban ecosystems, by assessing the presence of pathogens in public areas in the city of Bari (Apulia region, Italy). To determine the degree of environmental contamination, samples of dog faeces and bird guano were collected from different areas in the city of Bari (park green areas, playgrounds, public housing areas, parkways, and a school). A total of 152 canine faecal samples, in 54 pools, and two samples of pigeon guano from 66 monitored sites were examined. No samples were found in 12 areas spread over nine sites. Chlamydophila psittaci was detected in seven canine and two pigeon guano samples. Salmonella species were not found. On the other hand, four of 54 canine faecal samples were positive for reovirus. Thirteen canine faecal samples were positive for parasite eggs: 8/54 samples contained Toxocara canis and Toxascaris leonina eggs and 5/54 samples contained Ancylostoma caninum eggs. Our study showed that public areas are often contaminated by potentially zoonotic pathogens.
MRSA in Conventional and Alternative Retail Pork Products
O'Brien, Ashley M.; Hanson, Blake M.; Farina, Sarah A.; Wu, James Y.; Simmering, Jacob E.; Wardyn, Shylo E.; Forshey, Brett M.; Kulick, Marie E.; Wallinga, David B.; Smith, Tara C.
2012-01-01
In order to examine the prevalence of Staphylococcus aureus on retail pork, three hundred ninety-five pork samples were collected from a total of 36 stores in Iowa, Minnesota, and New Jersey. S. aureus was isolated from 256 samples (64.8%, 95% confidence interval [CI] 59.9%–69.5%). S. aureus was isolated from 67.3% (202/300) of conventional pork samples and from 56.8% (54/95) of alternative pork samples (labeled “raised without antibiotics” or “raised without antibiotic growth promotants”). Two hundred and thirty samples (58.2%, 95% CI 53.2%–63.1%) were found to carry methicillin-sensitive S. aureus (MSSA). MSSA was isolated from 61.0% (183/300) of conventional samples and from 49.5% (47/95) of alternative samples. Twenty-six pork samples (6.6%, 95% CI 4.3%–9.5%) carried methicillin-resistant S. aureus (MRSA). No statistically significant differences were observed for the prevalence of S. aureus in general, or MSSA or MRSA specifically, when comparing pork products from conventionally raised swine and swine raised without antibiotics, a finding that contrasts with a prior study from the Netherlands examining both conventional and “biologic” meat products. In our study spa types associated with “livestock-associated” ST398 (t034, t011) were found in 26.9% of the MRSA isolates, while 46.2% were spa types t002 and t008—common human types of MRSA that also have been found in live swine. The study represents the largest sampling of raw meat products for MRSA contamination to date in the U.S. MRSA prevalence on pork products was higher than in previous U.S.-conducted studies, although similar to that in Canadian studies. PMID:22276147
Saha-Shah, Anumita; Weber, Anna E.; Karty, Jonathan A.; Ray, Steven J.; Hieftje, Gary M.
2015-01-01
Nanopipettes (pipettes with diameters <1 μm) were explored as pressure-driven fluid manipulation tools for sampling nanoliter volumes of fluids. The fundamental behavior of fluids confined in the narrow channels of the nanopipette shank was studied to optimize sampling volume and probe geometry. This method was utilized to collect nanoliter volumes (<10 nL) of sample from single Allium cepa cells and live Drosophila melanogaster first instar larvae. Matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) was utilized to characterize the collected sample. The use of nanopipettes for surface sampling of mouse brain tissue sections was also explored. Lipid analyses were performed on mouse brain tissues with spatial resolution of sampling as small as 50 μm. Nanopipettes were shown to be a versatile tool that will find further application in studies of sample heterogeneity and population analysis for a wide range of samples. PMID:28706697
Sampling in research on interpersonal aggression.
Nielsen, Morten Birkeland; Einarsen, Ståle
2008-01-01
The aim of this study was to investigate the usefulness of convenience samples in research on interpersonal aggression among adults. It was hypothesised that convenience sampled targets of aggression differs from targets in general with regards to both demographic characteristics and degree of aggression exposed to. A convenience sample comprising support-seeking targets of workplace bullying was compared with a representative sample of Norwegian targets of bullying. The results showed that the two samples differed significantly on all demographic variables investigated, except gender. A far higher percentage of the convenience sample had blown the whistle on illegal, immoral or illegitimate practice at their workplace, whereas they also reported significantly more frequent and more intense exposure to aggression. The findings confirm that convenience samples have low external validity when generalising to the general population. Such samples should therefore mainly be used to investigate tendencies in, and the phenomenology of, interpersonal aggression, in studies where generalisability is not the principal objective. Copyright 2007 Wiley-Liss, Inc.
Olives, Casey; Pagano, Marcello; Deitchler, Megan; Hedt, Bethany L; Egge, Kari; Valadez, Joseph J
2009-01-01
Traditional lot quality assurance sampling (LQAS) methods require simple random sampling to guarantee valid results. However, cluster sampling has been proposed to reduce the number of random starting points. This study uses simulations to examine the classification error of two such designs, a 67×3 (67 clusters of three observations) and a 33×6 (33 clusters of six observations) sampling scheme to assess the prevalence of global acute malnutrition (GAM). Further, we explore the use of a 67×3 sequential sampling scheme for LQAS classification of GAM prevalence. Results indicate that, for independent clusters with moderate intracluster correlation for the GAM outcome, the three sampling designs maintain approximate validity for LQAS analysis. Sequential sampling can substantially reduce the average sample size that is required for data collection. The presence of intercluster correlation can impact dramatically the classification error that is associated with LQAS analysis. PMID:20011037
Distribution of the two-sample t-test statistic following blinded sample size re-estimation.
Lu, Kaifeng
2016-05-01
We consider the blinded sample size re-estimation based on the simple one-sample variance estimator at an interim analysis. We characterize the exact distribution of the standard two-sample t-test statistic at the final analysis. We describe a simulation algorithm for the evaluation of the probability of rejecting the null hypothesis at given treatment effect. We compare the blinded sample size re-estimation method with two unblinded methods with respect to the empirical type I error, the empirical power, and the empirical distribution of the standard deviation estimator and final sample size. We characterize the type I error inflation across the range of standardized non-inferiority margin for non-inferiority trials, and derive the adjusted significance level to ensure type I error control for given sample size of the internal pilot study. We show that the adjusted significance level increases as the sample size of the internal pilot study increases. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Hemolysis associated with pneumatic tube system transport for blood samples
Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih
2014-01-01
Objective: The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Methods: Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. Results: The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Conclusion: Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis. PMID:24639830
Recommendations for representative ballast water sampling
NASA Astrophysics Data System (ADS)
Gollasch, Stephan; David, Matej
2017-05-01
Until now, the purpose of ballast water sampling studies was predominantly limited to general scientific interest to determine the variety of species arriving in ballast water in a recipient port. Knowing the variety of species arriving in ballast water also contributes to the assessment of relative species introduction vector importance. Further, some sampling campaigns addressed awareness raising or the determination of organism numbers per water volume to evaluate the species introduction risk by analysing the propagule pressure of species. A new aspect of ballast water sampling, which this contribution addresses, is compliance monitoring and enforcement of ballast water management standards as set by, e.g., the IMO Ballast Water Management Convention. To achieve this, sampling methods which result in representative ballast water samples are essential. We recommend such methods based on practical tests conducted on two commercial vessels also considering results from our previous studies. The results show that different sampling approaches influence the results regarding viable organism concentrations in ballast water samples. It was observed that the sampling duration (i.e., length of the sampling process), timing (i.e., in which point in time of the discharge the sample is taken), the number of samples and the sampled water quantity are the main factors influencing the concentrations of viable organisms in a ballast water sample. Based on our findings we provide recommendations for representative ballast water sampling.
Leese, Elizabeth; Morton, Jackie; Gardiner, Philip H E; Carolan, Vikki A
2017-04-01
The analytical method outlined in this feasibility study has been used to show that trivalent chromium (Cr(III)) and hexavalent chromium (Cr(VI)) can be detected and measured in exhaled breath condensate (EBC) samples. EBC samples and urine samples were collected from a cohort of 58 workers occupationally exposed to hexavalent chromium compounds and 22 unexposed volunteers (control group). Levels of Cr(III) and Cr(VI) were determined in EBC samples and total chromium levels were determined in urine samples. Pre and post working week samples for both EBC and urine were collected in tandem. Total chromium in urine samples was analysed by inductively coupled plasma mass spectrometry (ICP-MS). Analysis of Cr(III) and Cr(VI) in EBC samples used a hyphenated micro liquid chromatography (μLC) system coupled to an ICP-MS. Separation was achieved using an anion exchange micro-sized column. The results showed that the occupationally exposed workers had significantly higher levels of Cr(III) and Cr(VI) in their EBC samples than the control group, as well as higher levels of total chromium in their urine samples. However, for the exposed workers no significant difference was found between pre and post working week EBC samples for either Cr(III) or Cr(VI). This study has established that Cr(III) and Cr(VI) can simultaneously be detected and measured in 'real' EBC samples and will help in understanding inhalation exposure. Crown Copyright © 2016. Published by Elsevier GmbH. All rights reserved.
Sample design effects in landscape genetics
Oyler-McCance, Sara J.; Fedy, Bradley C.; Landguth, Erin L.
2012-01-01
An important research gap in landscape genetics is the impact of different field sampling designs on the ability to detect the effects of landscape pattern on gene flow. We evaluated how five different sampling regimes (random, linear, systematic, cluster, and single study site) affected the probability of correctly identifying the generating landscape process of population structure. Sampling regimes were chosen to represent a suite of designs common in field studies. We used genetic data generated from a spatially-explicit, individual-based program and simulated gene flow in a continuous population across a landscape with gradual spatial changes in resistance to movement. Additionally, we evaluated the sampling regimes using realistic and obtainable number of loci (10 and 20), number of alleles per locus (5 and 10), number of individuals sampled (10-300), and generational time after the landscape was introduced (20 and 400). For a simulated continuously distributed species, we found that random, linear, and systematic sampling regimes performed well with high sample sizes (>200), levels of polymorphism (10 alleles per locus), and number of molecular markers (20). The cluster and single study site sampling regimes were not able to correctly identify the generating process under any conditions and thus, are not advisable strategies for scenarios similar to our simulations. Our research emphasizes the importance of sampling data at ecologically appropriate spatial and temporal scales and suggests careful consideration for sampling near landscape components that are likely to most influence the genetic structure of the species. In addition, simulating sampling designs a priori could help guide filed data collection efforts.
NASA Astrophysics Data System (ADS)
Breier, J. A.; Sheik, C. S.; Gomez-Ibanez, D.; Sayre-McCord, R. T.; Sanger, R.; Rauch, C.; Coleman, M.; Bennett, S. A.; Cron, B. R.; Li, M.; German, C. R.; Toner, B. M.; Dick, G. J.
2014-12-01
A new tool was developed for large volume sampling to facilitate marine microbiology and biogeochemical studies. It was developed for remotely operated vehicle and hydrocast deployments, and allows for rapid collection of multiple sample types from the water column and dynamic, variable environments such as rising hydrothermal plumes. It was used successfully during a cruise to the hydrothermal vent systems of the Mid-Cayman Rise. The Suspended Particulate Rosette V2 large volume multi-sampling system allows for the collection of 14 sample sets per deployment. Each sample set can include filtered material, whole (unfiltered) water, and filtrate. Suspended particulate can be collected on filters up to 142 mm in diameter and pore sizes down to 0.2 μm. Filtration is typically at flowrates of 2 L min-1. For particulate material, filtered volume is constrained only by sampling time and filter capacity, with all sample volumes recorded by digital flowmeter. The suspended particulate filter holders can be filled with preservative and sealed immediately after sample collection. Up to 2 L of whole water, filtrate, or a combination of the two, can be collected as part of each sample set. The system is constructed of plastics with titanium fasteners and nickel alloy spring loaded seals. There are no ferrous alloys in the sampling system. Individual sample lines are prefilled with filtered, deionized water prior to deployment and remain sealed unless a sample is actively being collected. This system is intended to facilitate studies concerning the relationship between marine microbiology and ocean biogeochemistry.
NASA Astrophysics Data System (ADS)
Kardanpour, Z.; Jacobsen, O. S.; Esbensen, K. H.
2015-06-01
This study is a contribution to development of a heterogeneity characterisation facility for "next generation" sampling aimed at more realistic and controllable pesticide variability in laboratory pots in experimental environmental contaminant assessment. The role of soil heterogeneity on quantification of a set of exemplar parameters, organic matter, loss on ignition (LOI), biomass, soil microbiology, MCPA sorption and mineralization is described, including a brief background on how heterogeneity affects sampling/monitoring procedures in environmental pollutant studies. The Theory of Sampling (TOS) and variographic analysis has been applied to develop a fit-for-purpose heterogeneity characterization approach. All parameters were assessed in large-scale profile (1-100 m) vs. small-scale (0.1-1 m) replication sampling pattern. Variographic profiles of experimental analytical results concludes that it is essential to sample at locations with less than a 2.5 m distance interval to benefit from spatial auto-correlation and thereby avoid unnecessary, inflated compositional variation in experimental pots; this range is an inherent characteristic of the soil heterogeneity and will differ among soils types. This study has a significant carrying-over potential for related research areas e.g. soil science, contamination studies, and environmental monitoring and environmental chemistry.
Pedersen, Casper-Emil T; Frandsen, Peter; Wekesa, Sabenzia N; Heller, Rasmus; Sangula, Abraham K; Wadsworth, Jemma; Knowles, Nick J; Muwanika, Vincent B; Siegismund, Hans R
2015-01-01
With the emergence of analytical software for the inference of viral evolution, a number of studies have focused on estimating important parameters such as the substitution rate and the time to the most recent common ancestor (tMRCA) for rapidly evolving viruses. Coupled with an increasing abundance of sequence data sampled under widely different schemes, an effort to keep results consistent and comparable is needed. This study emphasizes commonly disregarded problems in the inference of evolutionary rates in viral sequence data when sampling is unevenly distributed on a temporal scale through a study of the foot-and-mouth (FMD) disease virus serotypes SAT 1 and SAT 2. Our study shows that clustered temporal sampling in phylogenetic analyses of FMD viruses will strongly bias the inferences of substitution rates and tMRCA because the inferred rates in such data sets reflect a rate closer to the mutation rate rather than the substitution rate. Estimating evolutionary parameters from viral sequences should be performed with due consideration of the differences in short-term and longer-term evolutionary processes occurring within sets of temporally sampled viruses, and studies should carefully consider how samples are combined.
Knox, Stephanie A; Chondros, Patty
2004-01-01
Background Cluster sample study designs are cost effective, however cluster samples violate the simple random sample assumption of independence of observations. Failure to account for the intra-cluster correlation of observations when sampling through clusters may lead to an under-powered study. Researchers therefore need estimates of intra-cluster correlation for a range of outcomes to calculate sample size. We report intra-cluster correlation coefficients observed within a large-scale cross-sectional study of general practice in Australia, where the general practitioner (GP) was the primary sampling unit and the patient encounter was the unit of inference. Methods Each year the Bettering the Evaluation and Care of Health (BEACH) study recruits a random sample of approximately 1,000 GPs across Australia. Each GP completes details of 100 consecutive patient encounters. Intra-cluster correlation coefficients were estimated for patient demographics, morbidity managed and treatments received. Intra-cluster correlation coefficients were estimated for descriptive outcomes and for associations between outcomes and predictors and were compared across two independent samples of GPs drawn three years apart. Results Between April 1999 and March 2000, a random sample of 1,047 Australian general practitioners recorded details of 104,700 patient encounters. Intra-cluster correlation coefficients for patient demographics ranged from 0.055 for patient sex to 0.451 for language spoken at home. Intra-cluster correlations for morbidity variables ranged from 0.005 for the management of eye problems to 0.059 for management of psychological problems. Intra-cluster correlation for the association between two variables was smaller than the descriptive intra-cluster correlation of each variable. When compared with the April 2002 to March 2003 sample (1,008 GPs) the estimated intra-cluster correlation coefficients were found to be consistent across samples. Conclusions The demonstrated precision and reliability of the estimated intra-cluster correlations indicate that these coefficients will be useful for calculating sample sizes in future general practice surveys that use the GP as the primary sampling unit. PMID:15613248
Mueller, Silke C; Drewelow, Bernd
2013-05-01
The area under the concentration-time curve (AUC) after oral midazolam administration is commonly used for cytochrome P450 (CYP) 3A phenotyping studies. The aim of this investigation was to evaluate a limited sampling strategy for the prediction of AUC with oral midazolam. A total of 288 concentration-time profiles from 123 healthy volunteers who participated in four previously performed drug interaction studies with intense sampling after a single oral dose of 7.5 mg midazolam were available for evaluation. Of these, 45 profiles served for model building, which was performed by stepwise multiple linear regression, and the remaining 243 datasets served for validation. Mean prediction error (MPE), mean absolute error (MAE) and root mean squared error (RMSE) were calculated to determine bias and precision The one- to four-sampling point models with the best coefficient of correlation were the one-sampling point model (8 h; r (2) = 0.84), the two-sampling point model (0.5 and 8 h; r (2) = 0.93), the three-sampling point model (0.5, 2, and 8 h; r (2) = 0.96), and the four-sampling point model (0.5,1, 2, and 8 h; r (2) = 0.97). However, the one- and two-sampling point models were unable to predict the midazolam AUC due to unacceptable bias and precision. Only the four-sampling point model predicted the very low and very high midazolam AUC of the validation dataset with acceptable precision and bias. The four-sampling point model was also able to predict the geometric mean ratio of the treatment phase over the baseline (with 90 % confidence interval) results of three drug interaction studies in the categories of strong, moderate, and mild induction, as well as no interaction. A four-sampling point limited sampling strategy to predict the oral midazolam AUC for CYP3A phenotyping is proposed. The one-, two- and three-sampling point models were not able to predict midazolam AUC accurately.
STUDY OF HOME DEMONSTRATION UNITS IN A SAMPLE OF 27 COUNTIES IN NEW YORK STATE, NUMBER 3.
ERIC Educational Resources Information Center
ALEXANDER, FRANK D.; HARSHAW, JEAN
AN EXPLORATORY STUDY EXAMINED CHARACTERISTICS OF 1,128 HOME DEMONSTRATION UNITS TO SUGGEST HYPOTHESES AND SCOPE FOR A MORE INTENSIVE STUDY OF A SMALL SAMPLE OF UNITS, AND TO PROVIDE GUIDANCE IN SAMPLING. DATA WERE OBTAINED FROM A SPECIALLY DESIGNED MEMBERSHIP CARD USED IN 1962. UNIT SIZE AVERAGED 23.6 MEMBERS BUT THE RANGE WAS FAIRLY GREAT. A NEED…
ERIC Educational Resources Information Center
Price, Jay R.
This study sought information about selective service rejection in Delaware, specifically rejectee characteristics, reasons for rejection, and the high rejection rate in Delaware. The basic design was a modified case study method in which a sample of individual records were examined. Differences between this sample and national samples were tested…
ERIC Educational Resources Information Center
Maiano, Christophe; Morin, Alexandre J. S.; Begarie, Jerome
2011-01-01
The purpose of this study was to test the factor validity and reliability of the Center for Epidemiologic Studies Depression Scale (CES-D) within a sample of adolescents with mild to moderate Intellectual Disability (ID). A total sample of 189 adolescents (121 boys and 68 girls), aged between 12 and 18 years old, with mild to moderate ID were…
Inventory of Drug Samples in a Health Care Institution
Soucy, Geneviève; Bussières, Jean-François; Tardif, Lyne; Bailey, Benoît
2009-01-01
Background: Few data exist on the presence of drug samples in health care facilities. Although the use of drug samples has potential benefits, this practice is also controversial, as it can contribute to non-optimal drug use. The objective of this study was to evaluate the inventory of drug samples in a health care institution and to determine compliance with existing policies and procedures. Methods: This descriptive observational study was conducted in a university hospital centre from October 18 to November 1, 2007. A standardized data collection form was used for a physical inventory, which was intended to identify all drug samples available in the institution. The following information was recorded: number of locations where drug samples were found, primary patient care activity performed at each location, number of storage areas in the location, type of storage, presence of a lock, location of the key (if a lock was present), medical specialty, number of physicians and nurses likely to use the samples, reasons given for handing out samples, presence of a designated person to manage the samples, physical inventory (i.e., various details for each distribution unit), and declaration of samples to the pharmacy department. The inventory was conducted by 2 research assistants during day shifts. Results: A total of 84 locations were included in the inventory, and drug samples were found in 21 locations (with a total of 31 storage areas). All of the locations were intended for ambulatory patients (outpatient clinics and day centres). No drug samples were found in inpatient care units. The drug samples, which came from 62 different pharmaceutical companies, represented a total of 159 generic entities and 266 different brands. Of the distribution units for drug samples that were identified during this inventory, 59% were not on the hospital’s local formulary. Furthermore, only 3.5% of the distribution units had been declared to the pharmacy department, in accordance with established policy. The sample distribution units, including expired units, totalled 78 955 doses, with a total value of Can$48 783 (based on unit prices in effect in October 2007). Conclusion: This study presents an inventory of drug samples in an urban health care institution and reports compliance with the institution’s policies and procedures regarding drug samples. Samples were found only in outpatient clinics and represented 2.4 times the hospital’s floor stock of medications. Most of the samples inventoried were not listed on the hospital’s formulary. It appears that the use of drug samples is underestimated in hospital settings. Further studies are needed to evaluate the importance of drug samples and the risks associated with their use. PMID:22478908
Genomic regions associated with bovine milk fatty acids in both summer and winter milk samples
2012-01-01
Background In this study we perform a genome-wide association study (GWAS) for bovine milk fatty acids from summer milk samples. This study replicates a previous study where we performed a GWAS for bovine milk fatty acids based on winter milk samples from the same population. Fatty acids from summer and winter milk are genetically similar traits and we therefore compare the regions detected in summer milk to the regions previously detected in winter milk GWAS to discover regions that explain genetic variation in both summer and winter milk. Results The GWAS of summer milk samples resulted in 51 regions associated with one or more milk fatty acids. Results are in agreement with most associations that were previously detected in a GWAS of fatty acids from winter milk samples, including eight ‘new’ regions that were not considered in the individual studies. The high correlation between the –log10(P-values) and effects of SNPs that were found significant in both GWAS imply that the effects of the SNPs were similar on winter and summer milk fatty acids. Conclusions The GWAS of fatty acids based on summer milk samples was in agreement with most of the associations detected in the GWAS of fatty acids based on winter milk samples. Associations that were in agreement between both GWAS are more likely to be involved in fatty acid synthesis compared to regions detected in only one GWAS and are therefore worthwhile to pursue in fine-mapping studies. PMID:23107417
Abdollahi, Alireza; Hakimi, Faezeh; Doomanlou, Mahsa; Azadegan, Azadeh
2016-04-01
Preventing and starting early treatment of infections in patients whose immunity system is weak due to malignancies like leukemia can reduce mortality. This study aimed to determine microbial and antibiotic resistance patterns in clinical samples of patients with acute leukemia to start early treatment before the results of clinical tests are known. In this cross-sectional study, the clinical samples of all patients hospitalized with the diagnosis of acute leukemia were cultured and their antibiogram was evaluated. Then, the data were analyzed by SPSS 18 based on the objectives of the study. Of a total of 2,366 samples, 18.95% were reported to be positive blood samples, 22.96% were reported to be urine samples and 36% wound samples. E. coli was the most common bacteria isolated from the blood and urine cultures (34% in blood, 32% in urine culture) while Staphylococcus Aureus was the most common in the wound culture (35%). The highest level of sensitivity in the organisms with positive blood culture was to Ciprofloxacin, while in positive urine and wound culture was to Imipenem. The highest resistance in blood, urine and wound culture was to Cotrimoxazole. According to results obtained from this study, it is necessary to conduct appropriate studies on this issue in specific conditions in our country. The findings of this study can be used in clinics for more accurate diagnosis, more effective treatment before the results of clinical tests are known and also for prevention of infection in cancer patients.
Slice sampling technique in Bayesian extreme of gold price modelling
NASA Astrophysics Data System (ADS)
Rostami, Mohammad; Adam, Mohd Bakri; Ibrahim, Noor Akma; Yahya, Mohamed Hisham
2013-09-01
In this paper, a simulation study of Bayesian extreme values by using Markov Chain Monte Carlo via slice sampling algorithm is implemented. We compared the accuracy of slice sampling with other methods for a Gumbel model. This study revealed that slice sampling algorithm offers more accurate and closer estimates with less RMSE than other methods . Finally we successfully employed this procedure to estimate the parameters of Malaysia extreme gold price from 2000 to 2011.
Diwan, Vishal; Stålsby Lundborg, Cecilia; Tamhankar, Ashok J
2013-01-01
The presence of antibiotics in the environment and their subsequent impact on resistance development has raised concerns globally. Hospitals are a major source of antibiotics released into the environment. To reduce these residues, research to improve knowledge of the dynamics of antibiotic release from hospitals is essential. Therefore, we undertook a study to estimate seasonal and temporal variation in antibiotic release from two hospitals in India over a period of two years. For this, 6 sampling sessions of 24 hours each were conducted in the three prominent seasons of India, at all wastewater outlets of the two hospitals, using continuous and grab sampling methods. An in-house wastewater sampler was designed for continuous sampling. Eight antibiotics from four major antibiotic groups were selected for the study. To understand the temporal pattern of antibiotic release, each of the 24-hour sessions were divided in three sub-sampling sessions of 8 hours each. Solid phase extraction followed by liquid chromatography/tandem mass spectrometry (LC-MS/MS) was used to determine the antibiotic residues. Six of the eight antibiotics studied were detected in the wastewater samples. Both continuous and grab sampling methods indicated that the highest quantities of fluoroquinolones were released in winter followed by the rainy season and the summer. No temporal pattern in antibiotic release was detected. In general, in a common timeframe, continuous sampling showed less concentration of antibiotics in wastewater as compared to grab sampling. It is suggested that continuous sampling should be the method of choice as grab sampling gives erroneous results, it being indicative of the quantities of antibiotics present in wastewater only at the time of sampling. Based on our studies, calculations indicate that from hospitals in India, an estimated 89, 1 and 25 ng/L/day of fluroquinolones, metronidazole and sulfamethoxazole respectively, might be getting released into the environment per 100 hospital beds.
Bruce, James F.; Roberts, James J.; Zuellig, Robert E.
2018-05-24
The U.S. Geological Survey (USGS), in cooperation with Colorado Springs City Engineering and Colorado Springs Utilities, analyzed previously collected invertebrate data to determine the comparability among four sampling methods and two versions (2010 and 2017) of the Colorado Benthic Macroinvertebrate Multimetric Index (MMI). For this study, annual macroinvertebrate samples were collected concurrently (in space and time) at 15 USGS surface-water gaging stations in the Fountain Creek Basin from 2010 to 2012 using four sampling methods. The USGS monitoring project in the basin uses two of the methods and the Colorado Department of Public Health and Environment recommends the other two. These methods belong to two distinct sample types, one that targets single habitats and one that targets multiple habitats. The study results indicate that there are significant differences in MMI values obtained from the single-habitat and multihabitat sample types but methods from each program within each sample type produced comparable values. This study also determined that MMI values calculated by different versions of the Colorado Benthic Macroinvertebrate MMI are indistinguishable. This indicates that the Colorado Department of Public Health and Environment methods are comparable with the USGS monitoring project methods for single-habitat and multihabitat sample types. This report discusses the direct application of the study results to inform the revision of the existing USGS monitoring project in the Fountain Creek Basin.
Guo, Wenbin; Cui, Xilong; Liu, Feng; Chen, Jindong; Xie, Guangrong; Wu, Renrong; Zhang, Zhikun; Chen, Huafu; Zhao, Jingping
2018-01-01
Abnormal default-mode network (DMN) homogeneity has been involved in the neurophysiology of major depressive disorder (MDD) with inconsistent findings. The inconsistency may be due to clinical and methodological variability, and the reproducibility of the findings is limited. The present study aimed to examine alterations of the DMN homogeneity in two independent samples of patients with first-episode, drug-naive MDD. The samples included 59 patients with MDD and 31 comparison subjects from Sample 1 and 29 patients with MDD and 24 comparison subjects from Sample 2. Network homogeneity (NH) was computed with an overlapping technique, which was employed to define brain regions with abnormal NH common to the MDD samples. Compared with comparison subjects, patients with MDD exhibited increased NH in an overlapped brain region of the left superior medial prefrontal cortex (MPFC). No correlations were found between abnormal NH and HAMD total/subscale scores in the patients of each sample and in the combined patients from both samples. This study is the first to examine alterations of DMN homogeneity in first-episode, drug-naive patients with MDD in two independent samples by using an overlapping technique. Patients with MDD exhibit increased NH in an overlapped region in the anterior DMN. The present study thus highlights the importance of the DMN in the neurophysiology of MDD. Copyright © 2017 Elsevier B.V. All rights reserved.
Factor Structure of the Internet Addiction Test in Online Gamers and Poker Players.
Khazaal, Yasser; Achab, Sophia; Billieux, Joel; Thorens, Gabriel; Zullino, Daniele; Dufour, Magali; Rothen, Stéphane
2015-01-01
The Internet Addiction Test (IAT) is the most widely used questionnaire to screen for problematic Internet use. Nevertheless, its factorial structure is still debated, which complicates comparisons among existing studies. Most previous studies were performed with students or community samples despite the probability of there being more problematic Internet use among users of specific applications, such as online gaming or gambling. To assess the factorial structure of a modified version of the IAT that addresses specific applications, such as video games and online poker. Two adult samples-one sample of Internet gamers (n=920) and one sample of online poker players (n=214)-were recruited and completed an online version of the modified IAT. Both samples were split into two subsamples. Two principal component analyses (PCAs) followed by two confirmatory factor analyses (CFAs) were run separately. The results of principal component analysis indicated that a one-factor model fit the data well across both samples. In consideration of the weakness of some IAT items, a 17-item modified version of the IAT was proposed. This study assessed, for the first time, the factorial structure of a modified version of an Internet-administered IAT on a sample of Internet gamers and a sample of online poker players. The scale seems appropriate for the assessment of such online behaviors. Further studies on the modified 17-item IAT version are needed.
Impact of Processing Method on Recovery of Bacteria from Wipes Used in Biological Surface Sampling
Olson, Nathan D.; Filliben, James J.; Morrow, Jayne B.
2012-01-01
Environmental sampling for microbiological contaminants is a key component of hygiene monitoring and risk characterization practices utilized across diverse fields of application. However, confidence in surface sampling results, both in the field and in controlled laboratory studies, has been undermined by large variation in sampling performance results. Sources of variation include controlled parameters, such as sampling materials and processing methods, which often differ among studies, as well as random and systematic errors; however, the relative contributions of these factors remain unclear. The objective of this study was to determine the relative impacts of sample processing methods, including extraction solution and physical dissociation method (vortexing and sonication), on recovery of Gram-positive (Bacillus cereus) and Gram-negative (Burkholderia thailandensis and Escherichia coli) bacteria from directly inoculated wipes. This work showed that target organism had the largest impact on extraction efficiency and recovery precision, as measured by traditional colony counts. The physical dissociation method (PDM) had negligible impact, while the effect of the extraction solution was organism dependent. Overall, however, extraction of organisms from wipes using phosphate-buffered saline with 0.04% Tween 80 (PBST) resulted in the highest mean recovery across all three organisms. The results from this study contribute to a better understanding of the factors that influence sampling performance, which is critical to the development of efficient and reliable sampling methodologies relevant to public health and biodefense. PMID:22706055
Fujimura, Kei E.; Rauch, Marcus; Matsui, Elizabeth; Iwai, Shoko; Calatroni, Agustin; Lynn, Henry; Mitchell, Herman; Johnson, Christine C.; Gern, James E.; Togias, Alkis; Boushey, Homer A.; Kennedy, Suzanne; Lynch, Susan V.
2013-01-01
Summary Standardized studies examining environmental microbial exposure in populations at risk for asthma are necessary to improve our understanding of the role this factor plays in disease development. Here we describe studies aimed at developing guidelines for high-resolution culture-independent microbiome profiling, using a phylogenetic microarray (PhyloChip), of house dust samples in a cohort collected as part of the NIH-funded Inner City Asthma Consortium (ICAC). We demonstrate that though extracted DNA concentrations varied across dust samples, the majority produced sufficient 16S rRNA to be profiled by the array. Comparison of array and 454-pyrosequencing performed in parallel on a subset of samples, illustrated that increasingly deeper sequencing efforts validated greater numbers of array-detected taxa. Community composition agreement across samples exhibited a hierarchy in concordance, with the highest level of agreement in replicate array profiles followed by samples collected from adjacent 1×1 m2 sites in the same room, adjacent sites with different sized sampling quadrants (1×1 and 2×2 m2), different sites within homes (living and bedroom) to lowest in living room samples collected from different homes. The guidelines for sample collection and processing in this pilot study extend beyond PhyloChip based studies of house-associated microbiota, and bear relevance for other microbiome profiling approaches such as next-generation sequencing. PMID:22975469
Arcobacter Isolation from Minced Beef Samples in Costa Rica.
Córdoba-Calderón, Oscar; Redondo-Solano, Mauricio; Castro-Arias, Eduardo; Arias-EchandI, María Laura
2017-04-03
The presence of Arcobacter spp. in minced meat (including beef) samples has been well documented in different countries, with varying frequencies. Nevertheless, the only Latin American country reporting this bacterium in minced beef samples is Mexico, with a 28.8% frequency in 2003. Previous studies in Costa Rica have demonstrated the presence of Arcobacter species in samples taken from the poultry production chain, but still there are no studies performed in bovine meat. The aim of this study was to determine the frequency of this bacterium in 120 samples of minced beef acquired from the Central Valley region of Costa Rica and to describe the antibiotic sensitivity pattern of the isolates obtained. A total of 75 different Arcobacter strains were isolated from minced beef samples, for a final frequency of 48.3%. After species PCR identification, the strains were classified as A. butzleri (37.3%), A. cibarius (14.7%), A. thereius (12%), and Arcobacter spp. (36%). All samples were sensitive to gentamicin but were resistant to ampicillin, levofloxacin, nalidixic acid, and ciprofloxacin. The results obtained in this study show that the frequency of isolation of Arcobacter in minced beef samples is high and that there is a high resistance rate for antibiotics in common use. This suggests that Arcobacter represents a health risk for Costa Rica and that control measures should be developed to decrease its potential impact.
Saravanan, R; Karthikeyan, N; Gupta, V K; Thirumal, E; Thangadurai, P; Narayanan, V; Stephen, A
2013-05-01
Degradation of model organic dye and industry effluent was studied using different weight percentages of Ag into ZnO as a catalyst. In this study, the catalysts were prepared by thermal decomposition method, which was employed for the first time in the preparation of ZnO/Ag nanocomposite catalysts. The physical and chemical properties of the prepared samples were studied using various techniques. The specific surface area, which plays an important role in the photocatalytic degradation, was studied using BET analysis and 10 wt.% Ag into ZnO showed the best degrading efficiency. The optical absorption (UV-vis) and emission (PL) properties of the samples were studied and results suggest better photocatalytic properties for 10 wt.% Ag sample compared to other samples. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.
Health Status of Gulf War and Era Veterans Serving in the US Military in 2000.
Porter, Ben; Long, Kyna; Rull, Rudolph P; Dursa, Erin K
2018-05-01
This research describes Gulf War and era veterans enrolled in the Millennium Cohort Study, who were sampled from US military personnel serving in 2000, and compares health characteristics of this sample to a Department of Veterans Affairs study sampled from the complete population. Demographics characteristics of this sample were described. Self-reported health characteristics were compared between the two studies. Gulf War and era veterans in the Millennium Cohort were generally healthier than in the VA study; they had fewer medical conditions and mental health disorders and better self-reported health. In both studies, Gulf War veterans had poorer health outcomes than era veterans. The Millennium Cohort Study is a unique resource for examining the long-term health effects of Gulf War deployment, particularly comparing deployed and nondeployed personnel and examining illnesses with long latencies.
Button, Mark; Weber, Kela; Nivala, Jaime; Aubron, Thomas; Müller, Roland Arno
2016-03-01
Community-level physiological profiling (CLPP) using BIOLOG® EcoPlates™ has become a popular method for characterizing and comparing the functional diversity, functional potential, and metabolic activity of heterotrophic microbial communities. The method was originally developed for profiling soil communities; however, its usage has expanded into the fields of ecotoxicology, agronomy, and the monitoring and profiling of microbial communities in various wastewater treatment systems, including constructed wetlands for water pollution control. When performing CLPP on aqueous samples from constructed wetlands, a wide variety of sample characteristics can be encountered and challenges may arise due to excessive solids, color, or turbidity. The aim of this study was to investigate the impacts of different sample preparation methods on CLPP performed on a variety of aqueous samples covering a broad range of physical and chemical characteristics. The results show that using filter paper, centrifugation, or settling helped clarify samples for subsequent CLPP analysis, however did not do so as effectively as dilution for the darkest samples. Dilution was able to provide suitable clarity for the darkest samples; however, 100-fold dilution significantly affected the carbon source utilization patterns (CSUPs), particularly with samples that were already partially or fully clear. Ten-fold dilution also had some effect on the CSUPs of samples which were originally clear; however, the effect was minimal. Based on these findings, for this specific set of samples, a 10-fold dilution provided a good balance between ease of use, sufficient clarity (for dark samples), and limited effect on CSUPs. The process and findings outlined here can hopefully serve future studies looking to utilize CLPP for functional analysis of microbial communities and also assist in comparing data from studies where different sample preparation methods were utilized.
Kremastinou, J.; Polymerou, V.; Lavranos, D.; Aranda Arrufat, A.; Harwood, J.; Martínez Lorenzo, M. J.; Ng, K. P.; Queiros, L.; Vereb, I.
2016-01-01
Treponema pallidum infections can have severe complications if not diagnosed and treated at an early stage. Screening and diagnosis of syphilis require assays with high specificity and sensitivity. The Elecsys Syphilis assay is an automated treponemal immunoassay for the detection of antibodies against T. pallidum. The performance of this assay was investigated previously in a multicenter study. The current study expands on that evaluation in a variety of diagnostic settings and patient populations, at seven independent laboratories. The samples included routine diagnostic samples, blood donation samples, samples from patients with confirmed HIV infections, samples from living organ or bone marrow donors, and banked samples, including samples previously confirmed as syphilis positive. This study also investigated the seroconversion sensitivity of the assay. With a total of 1,965 syphilis-negative routine diagnostic samples and 5,792 syphilis-negative samples collected from blood donations, the Elecsys Syphilis assay had specificity values of 99.85% and 99.86%, respectively. With 333 samples previously identified as syphilis positive, the sensitivity was 100% regardless of disease stage. The assay also showed 100% sensitivity and specificity with samples from 69 patients coinfected with HIV. The Elecsys Syphilis assay detected infection in the same bleed or earlier, compared with comparator assays, in a set of sequential samples from a patient with primary syphilis. In archived serial blood samples collected from 14 patients with direct diagnoses of primary syphilis, the Elecsys Syphilis assay detected T. pallidum antibodies for 3 patients for whom antibodies were not detected with the Architect Syphilis TP assay, indicating a trend for earlier detection of infection, which may have the potential to shorten the time between infection and reactive screening test results. PMID:27358468
A normative inference approach for optimal sample sizes in decisions from experience
Ostwald, Dirk; Starke, Ludger; Hertwig, Ralph
2015-01-01
“Decisions from experience” (DFE) refers to a body of work that emerged in research on behavioral decision making over the last decade. One of the major experimental paradigms employed to study experience-based choice is the “sampling paradigm,” which serves as a model of decision making under limited knowledge about the statistical structure of the world. In this paradigm respondents are presented with two payoff distributions, which, in contrast to standard approaches in behavioral economics, are specified not in terms of explicit outcome-probability information, but by the opportunity to sample outcomes from each distribution without economic consequences. Participants are encouraged to explore the distributions until they feel confident enough to decide from which they would prefer to draw from in a final trial involving real monetary payoffs. One commonly employed measure to characterize the behavior of participants in the sampling paradigm is the sample size, that is, the number of outcome draws which participants choose to obtain from each distribution prior to terminating sampling. A natural question that arises in this context concerns the “optimal” sample size, which could be used as a normative benchmark to evaluate human sampling behavior in DFE. In this theoretical study, we relate the DFE sampling paradigm to the classical statistical decision theoretic literature and, under a probabilistic inference assumption, evaluate optimal sample sizes for DFE. In our treatment we go beyond analytically established results by showing how the classical statistical decision theoretic framework can be used to derive optimal sample sizes under arbitrary, but numerically evaluable, constraints. Finally, we critically evaluate the value of deriving optimal sample sizes under this framework as testable predictions for the experimental study of sampling behavior in DFE. PMID:26441720
Expressed prostate secretions in the study of human papillomavirus epidemiology in the male.
Smelov, Vitaly; Eklund, Carina; Bzhalava, Davit; Novikov, Andrey; Dillner, Joakim
2013-01-01
Exploring different sampling sites and methods is of interest for studies of the epidemiology of HPV infections in the male. Expressed prostate secretions (EPS) are obtained during digital rectal examination (DRE), a daily routine urological diagnostic procedure, following massage of the prostate. Urethral swabs and EPS samples were obtained from a consecutive sample of 752 men (mean age 32.4 years; median life-time sex partners 34) visiting urology outpatient clinics in St. Petersburg, Russia and tested for HPV DNA by general primer PCR, followed by genotyping using Luminex. Overall, 47.9% (360/752) of men were HPV-positive, with 42.0% (316/752) being positive for high-risk (HR-) HPV and 12.6% (95/752) for multiple HPV types. HPV-positivity in the EPS samples was 32.6% (27.7% HR-HPV) and in the urethral samples 25.9% (24.5% HR-HPV). 10.6% were HPV positive in both EPS and urethral samples. 6.4% had the same HPV-type in both EPS and urethral samples. 10.6% were HPV positive in both EPS and urethral samples. 6.4% had the same HPV-type in both EPS and urethral samples. The concordance between the urethral samples and EPS was 62.5% (470/752), with 80 cases double positive and 390 cases double negative in both sites. The sensitivity of urethral samples for overall HPV detection was 54.2% (195/360). Compared to analysis of urethral samples only, the analysis of EPS increased the HPV prevalence in this population with 26.2%. EPS represent informative sampling material for the study of HPV epidemiology in the male.
Trace element contamination in feather and tissue samples from Anna’s hummingbirds
Mikoni, Nicole A.; Poppenga, Robert H.; Ackerman, Joshua T.; Foley, Janet E.; Hazlehurst, Jenny; Purdin, Güthrum; Aston, Linda; Hargrave, Sabine; Jelks, Karen; Tell, Lisa A.
2017-01-01
Trace element contamination (17 elements; Be, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Mo, Cd, Ba, Hg, Tl, and Pb) of live (feather samples only) and deceased (feather and tissue samples) Anna's hummingbirds (Calypte anna) was evaluated. Samples were analyzed using inductively coupled plasma-mass spectrometry (ICP-MS; 17 elements) and atomic absorption spectrophotometry (Hg only). Mean plus one standard deviation (SD) was considered the benchmark, and concentrations above the mean + 1 SD were considered elevated above normal. Contour feathers were sampled from live birds of varying age, sex, and California locations. In order to reduce thermal impacts, minimal feathers were taken from live birds, therefore a novel method was developed for preparation of low mass feather samples for ICP-MS analysis. The study found that the novel feather preparation method enabled small mass feather samples to be analyzed for trace elements using ICP-MS. For feather samples from live birds, all trace elements, with the exception of beryllium, had concentrations above the mean + 1 SD. Important risk factors for elevated trace element concentrations in feathers of live birds were age for iron, zinc, and arsenic, and location for iron, manganese, zinc, and selenium. For samples from deceased birds, ICP-MS results from body and tail feathers were correlated for Fe, Zn, and Pb, and feather concentrations were correlated with renal (Fe, Zn, Pb) or hepatic (Hg) tissue concentrations. Results for AA spectrophotometry analyzed samples from deceased birds further supported the ICP-MS findings where a strong correlation between mercury concentrations in feather and tissue (pectoral muscle) samples was found. These study results support that sampling feathers from live free-ranging hummingbirds might be a useful, non-lethal sampling method for evaluating trace element exposure and provides a sampling alternative since their small body size limits traditional sampling of blood and tissues. The results from this study provide a benchmark for the distribution of trace element concentrations in feather and tissue samples from hummingbirds and suggests a reference mark for exceeding normal. Lastly, pollinating avian species are minimally represented in the literature as bioindicators for environmental trace element contamination. Given that trace elements can move through food chains by a variety of routes, our study indicates that hummingbirds are possible bioindicators of environmental trace element contamination.
Williams, M S; Ebel, E D; Cao, Y
2013-01-01
The fitting of statistical distributions to microbial sampling data is a common application in quantitative microbiology and risk assessment applications. An underlying assumption of most fitting techniques is that data are collected with simple random sampling, which is often times not the case. This study develops a weighted maximum likelihood estimation framework that is appropriate for microbiological samples that are collected with unequal probabilities of selection. A weighted maximum likelihood estimation framework is proposed for microbiological samples that are collected with unequal probabilities of selection. Two examples, based on the collection of food samples during processing, are provided to demonstrate the method and highlight the magnitude of biases in the maximum likelihood estimator when data are inappropriately treated as a simple random sample. Failure to properly weight samples to account for how data are collected can introduce substantial biases into inferences drawn from the data. The proposed methodology will reduce or eliminate an important source of bias in inferences drawn from the analysis of microbial data. This will also make comparisons between studies and the combination of results from different studies more reliable, which is important for risk assessment applications. © 2012 No claim to US Government works.
Rodrigues, João Fabrício Mota; Coelho, Marco Túlio Pacheco
2016-01-01
Sampling the biodiversity is an essential step for conservation, and understanding the efficiency of sampling methods allows us to estimate the quality of our biodiversity data. Sex ratio is an important population characteristic, but until now, no study has evaluated how efficient are the sampling methods commonly used in biodiversity surveys in estimating the sex ratio of populations. We used a virtual ecologist approach to investigate whether active and passive capture methods are able to accurately sample a population's sex ratio and whether differences in movement pattern and detectability between males and females produce biased estimates of sex-ratios when using these methods. Our simulation allowed the recognition of individuals, similar to mark-recapture studies. We found that differences in both movement patterns and detectability between males and females produce biased estimates of sex ratios. However, increasing the sampling effort or the number of sampling days improves the ability of passive or active capture methods to properly sample sex ratio. Thus, prior knowledge regarding movement patterns and detectability for species is important information to guide field studies aiming to understand sex ratio related patterns.
Rodrigues, João Fabrício Mota; Coelho, Marco Túlio Pacheco
2016-01-01
Sampling the biodiversity is an essential step for conservation, and understanding the efficiency of sampling methods allows us to estimate the quality of our biodiversity data. Sex ratio is an important population characteristic, but until now, no study has evaluated how efficient are the sampling methods commonly used in biodiversity surveys in estimating the sex ratio of populations. We used a virtual ecologist approach to investigate whether active and passive capture methods are able to accurately sample a population’s sex ratio and whether differences in movement pattern and detectability between males and females produce biased estimates of sex-ratios when using these methods. Our simulation allowed the recognition of individuals, similar to mark-recapture studies. We found that differences in both movement patterns and detectability between males and females produce biased estimates of sex ratios. However, increasing the sampling effort or the number of sampling days improves the ability of passive or active capture methods to properly sample sex ratio. Thus, prior knowledge regarding movement patterns and detectability for species is important information to guide field studies aiming to understand sex ratio related patterns. PMID:27441554
Bingley, Polly J; Rafkin, Lisa E; Matheson, Della; Steck, Andrea K; Yu, Liping; Henderson, Courtney; Beam, Craig A; Boulware, David C
2015-12-01
Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot-based screening to identify islet autoantibody-positive relatives potentially eligible for inclusion in prevention trials. Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies.
Reproducibility of preclinical animal research improves with heterogeneity of study samples
Vogt, Lucile; Sena, Emily S.; Würbel, Hanno
2018-01-01
Single-laboratory studies conducted under highly standardized conditions are the gold standard in preclinical animal research. Using simulations based on 440 preclinical studies across 13 different interventions in animal models of stroke, myocardial infarction, and breast cancer, we compared the accuracy of effect size estimates between single-laboratory and multi-laboratory study designs. Single-laboratory studies generally failed to predict effect size accurately, and larger sample sizes rendered effect size estimates even less accurate. By contrast, multi-laboratory designs including as few as 2 to 4 laboratories increased coverage probability by up to 42 percentage points without a need for larger sample sizes. These findings demonstrate that within-study standardization is a major cause of poor reproducibility. More representative study samples are required to improve the external validity and reproducibility of preclinical animal research and to prevent wasting animals and resources for inconclusive research. PMID:29470495
1988-03-01
Polyimides as Planarizing and Insulative Coatings 2-21 III. Experimental Procedure, Equipment, and Materials 3-1 Wet Orientation Dependent Etching Study 3...1 Die Bond Adhesives Study .3-7 Fabrication of Samples for Electrical Testing 3-21 Evaluation of the Final Samples 3-45 IV. Experimental Results and...Discussion .. 4-1 We :ientation Dependent Etching Study Results 4-1 Die Attach Adhesives Study Results 4-21 Fabrication of Samples for Electrical
Considerations for throughfall chemistry sample-size determination
Pamela J. Edwards; Paul Mohai; Howard G. Halverson; David R. DeWalle
1989-01-01
Both the number of trees sampled per species and the number of sampling points under each tree are important throughfall sampling considerations. Chemical loadings obtained from an urban throughfall study were used to evaluate the relative importance of both of these sampling factors in tests for determining species' differences. Power curves for detecting...
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--QA ANALYTICAL RESULTS FOR METALS IN SPIKE SAMPLES
The Metals in Spike Samples data set contains the analytical results of measurements of up to 11 metals in 15 control samples (spikes) from 11 households. Measurements were made in spiked samples of dust, food, and dermal wipe residue. Spiked samples were used to assess recover...
An Investigation of the Sampling Distribution of the Congruence Coefficient.
ERIC Educational Resources Information Center
Broadbooks, Wendy J.; Elmore, Patricia B.
This study developed and investigated an empirical sampling distribution of the congruence coefficient. The effects of sample size, number of variables, and population value of the congruence coefficient on the sampling distribution of the congruence coefficient were examined. Sample data were generated on the basis of the common factor model and…
Niimi, Shingo; Nishimiya, Kazuhiro; Nishidate, Masanobu; Saito, Tetsu; Minoura, Kyoko; Kadotsuji, Kenta; Shimakura, Jin; Shigemizu, Hiroko; Hosogi, Jun; Adachi, Maiko; Hashimoto, Tsutomu; Mori, Tamiki; Harada, Hideki; Yamamoto, Ken-Ichi; Nakamura, Takahiro; Nomura, Tatsuki; Yamaguchi, Itadaki; Sonehara, Kazuhiko; Ishii-Watabe, Akiko; Kawasaki, Nana
2018-04-01
This study was undertaken to evaluate the performance of anti-drug antibody (ADA) assays constructed by each participating company using common samples including ADA, drug and human serum. The ADA assays constructed by each company showed good sensitivity and precision for evaluation of ADA. Cut points for screening and confirmatory assays and assay selectivity were determined by various calculation methods. In evaluations of blind ADA samples, nearly similar results were obtained by the study companies in determinations of whether samples were positive or negative except at the lowest sample concentration (5 ng/mL). In measurement of drug tolerance, for almost samples containing ADA and drugs, more positive results were obtained in assays using acid dissociation compared to those without acid dissociation. Overall, the performance of ADA assays constructed by the 10 companies participating in this study was acceptable in terms of sensitivity and reproducibility for detection and evaluation of immunogenicity in both patients and healthy subjects. On the other hand, based on results for samples containing ADA and drugs, validity of results for ADA assays conducted without acid dissociation was less meaningful and more difficult to evaluate. Thus, acid dissociation was confirmed to be useful for improving drug tolerance. Copyright © 2018 The Japanese Society for the Study of Xenobiotics. Published by Elsevier Ltd. All rights reserved.
Research on stored biological samples: views of African American and White American cancer patients.
Pentz, Rebecca D; Billot, Laurent; Wendler, David
2006-04-01
Proposals on consent for research with biological samples should be informed by empirical studies of individuals' views. Studies to date queried mostly white research subjects. The aim of this study was to compare the views of two groups of patients: cancer patients at a university clinic (Winship Cancer Institute at Emory Healthcare) and cancer patients at an inner city county hospital (Grady) who were given the option of tissue banking. Overall, 315/452 (70%) patients completed the survey. The Grady cohort was 86% African American; the Winship cohort was 82% White. The vast majority (95%) of individuals in both cohorts agreed to provide a biological sample for future research. Both cohorts were willing for their samples to be used to study cancer and other diseases, including Alzheimer disease. Few participants preferred to control the disease to be studied (10%) or wished to be contacted again for consent for each future research project (11%). In our sample, almost all clinical patients, regardless of site of care, ethnicity or socioeconomic status, were willing to provide a biological sample for research purposes and allow investigators to determine the research to be done without contacting the patients again. These findings support the recommendation to offer individuals a simplified consent with a one-time binary choice whether to provide biological samples for future research. Copyright 2006 Wiley-Liss, Inc.
Bhagavatula, Jyotsna; Singh, Lalji
2006-10-17
Bengal tiger Panthera tigris tigris the National Animal of India, is an endangered species. Estimating populations for such species is the main objective for designing conservation measures and for evaluating those that are already in place. Due to the tiger's cryptic and secretive behaviour, it is not possible to enumerate and monitor its populations through direct observations; instead indirect methods have always been used for studying tigers in the wild. DNA methods based on non-invasive sampling have not been attempted so far for tiger population studies in India. We describe here a pilot study using DNA extracted from faecal samples of tigers for the purpose of population estimation. In this study, PCR primers were developed based on tiger-specific variations in the mitochondrial cytochrome b for reliably identifying tiger faecal samples from those of sympatric carnivores. Microsatellite markers were developed for the identification of individual tigers with a sibling Probability of Identity of 0.005 that can distinguish even closely related individuals with 99.9% certainty. The effectiveness of using field-collected tiger faecal samples for DNA analysis was evaluated by sampling, identification and subsequently genotyping samples from two protected areas in southern India. Our results demonstrate the feasibility of using tiger faecal matter as a potential source of DNA for population estimation of tigers in protected areas in India in addition to the methods currently in use.
Sekar, R; Deines, P; Machell, J; Osborn, A M; Biggs, C A; Boxall, J B
2012-06-01
To determine the spatial and temporal variability in the abundance, structure and composition of planktonic bacterial assemblages sampled from a small, looped water distribution system and to interpret results with respect to hydraulic conditions. Water samples were collected from five sampling points, twice a day at 06:00 h and 09:00 h on a Monday (following low weekend demand) and a Wednesday (higher midweek demand). All samples were fully compliant with current regulated parameter standards. This study did not show obvious changes in bacterial abundance (DAPI count) or community structure Denaturing gradient gel electrophoresis analysis with respect to sample site and hence to water age; however, the study did show temporal variability with respect to both sampling day and sample times. Data suggests that variations in the bacterial assemblages may be associated with the local system hydraulics: the bacterial composition and numbers, over short durations, are governed by the interaction of the bulk water and the biofilm influenced by the hydraulic conditions. This study demonstrates general stability in bacterial abundance, community structure and composition within the system studied. Trends and patterns supporting the transfer of idealized understanding to the real world were evident. Ultimately, such work will help to safeguard potable water quality, fundamental to public health. © 2012 The Authors. Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.
Investigating Test Equating Methods in Small Samples through Various Factors
ERIC Educational Resources Information Center
Asiret, Semih; Sünbül, Seçil Ömür
2016-01-01
In this study, equating methods for random group design using small samples through factors such as sample size, difference in difficulty between forms, and guessing parameter was aimed for comparison. Moreover, which method gives better results under which conditions was also investigated. In this study, 5,000 dichotomous simulated data…
Who Are We Studying? Sample Diversity in Teaching of Psychology Research
ERIC Educational Resources Information Center
Richmond, Aaron S.; Broussard, Kristin A.; Sterns, Jillian L.; Sanders, Kristina K.; Shardy, Justin C.
2015-01-01
The purpose of the current study was to examine the sample diversity of empirical articles published in four premier teaching of psychology journals from 2008 to 2013. We investigated which demographic information was commonly reported and if samples were ethnically representative and whether gender was representative compared to National…
Sampling Methods and the Accredited Population in Athletic Training Education Research
ERIC Educational Resources Information Center
Carr, W. David; Volberding, Jennifer
2009-01-01
Context: We describe methods of sampling the widely-studied, yet poorly defined, population of accredited athletic training education programs (ATEPs). Objective: There are two purposes to this study; first to describe the incidence and types of sampling methods used in athletic training education research, and second to clearly define the…
The purpose of this SOP is to outline sample custody guidelines used by the Arizona Border Study. This procedure was followed to maintain sample integrity and ensure consistent data retrieval, transport, storage, shipment, and analysis during the Arizona NHEXAS project and the B...
Previous studies showed that disinfected drinking water samples gave mutagenic spectra typical of halogenated furanones. In this study, we used the TA7000 base-¿specific Salmonella typhimurium tester strains to characterize water samples from two drinking water treatment plants (...
ERIC Educational Resources Information Center
Ebert, Kerry Danahy; Pham, Giang
2017-01-01
Purpose: Although language samples and standardized tests are regularly used in assessment, few studies provide clinical guidance on how to synthesize information from these testing tools. This study extends previous work on the relations between tests and language samples to a new population--school-age bilingual speakers with primary language…
The Minnesota Children's Pesticide Exposure Study is a probability-based sample of 102 children 3-13 years old who were monitored for commonly used pesticides. During the summer of 1997, first-morning-void urine samples (1-3 per child) were obtained for 88% of study children a...
Technology Tips: Sample Too Small? Probably Not!
ERIC Educational Resources Information Center
Strayer, Jeremy F.
2013-01-01
Statistical studies are referenced in the news every day, so frequently that people are sometimes skeptical of reported results. Often, no matter how large a sample size researchers use in their studies, people believe that the sample size is too small to make broad generalizations. The tasks presented in this article use simulations of repeated…
Valid statistical inference methods for a case-control study with missing data.
Tian, Guo-Liang; Zhang, Chi; Jiang, Xuejun
2018-04-01
The main objective of this paper is to derive the valid sampling distribution of the observed counts in a case-control study with missing data under the assumption of missing at random by employing the conditional sampling method and the mechanism augmentation method. The proposed sampling distribution, called the case-control sampling distribution, can be used to calculate the standard errors of the maximum likelihood estimates of parameters via the Fisher information matrix and to generate independent samples for constructing small-sample bootstrap confidence intervals. Theoretical comparisons of the new case-control sampling distribution with two existing sampling distributions exhibit a large difference. Simulations are conducted to investigate the influence of the three different sampling distributions on statistical inferences. One finding is that the conclusion by the Wald test for testing independency under the two existing sampling distributions could be completely different (even contradictory) from the Wald test for testing the equality of the success probabilities in control/case groups under the proposed distribution. A real cervical cancer data set is used to illustrate the proposed statistical methods.
Erickson, Melinda L.
2012-01-01
The U.S. Geological Survey, in cooperation with the Minnesota Pollution Control Agency, completed a study on the occurrence of steroidal hormones and other endocrine active compounds in shallow groundwater in nonagricultural areas of Minnesota during 2009–10. This report describes the study design and methods, and presents the data collected on steroidal hormones and other related compounds. Environmental and quality-control samples were collected from 40 wells as part of this study. Samples were analyzed by the U.S. Geological Survey National Water Quality Laboratory for 16 steroidal hormones and 4 other related compounds, of which all but 2 compounds are endocrine active compounds. Most of the water samples did not contain detectable concentrations of any of the 20 compounds analyzed. Water samples from three wells had detectable concentrations of one or more compounds. Bisphenol A was detected in samples from three wells, and trans-diethylstilbestrol was detected in one of the samples in which bisphenol A also was detected.
Inactivation of RNA Viruses by Gamma Irradiation: A Study on Mitigating Factors
Hume, Adam J.; Ames, Joshua; Rennick, Linda J.; Duprex, W. Paul; Marzi, Andrea; Tonkiss, John; Mühlberger, Elke
2016-01-01
Effective inactivation of biosafety level 4 (BSL-4) pathogens is vital in order to study these agents safely. Gamma irradiation is a commonly used method for the inactivation of BSL-4 viruses, which among other advantages, facilitates the study of inactivated yet morphologically intact virions. The reported values for susceptibility of viruses to inactivation by gamma irradiation are sometimes inconsistent, likely due to differences in experimental protocols. We analyzed the effects of common sample attributes on the inactivation of a recombinant vesicular stomatitis virus expressing the Zaire ebolavirus glycoprotein and green fluorescent protein. Using this surrogate virus, we found that sample volume and protein content of the sample modulated viral inactivation by gamma irradiation but that air volume within the sample container and the addition of external disinfectant surrounding the sample did not. These data identify several factors which alter viral susceptibility to inactivation and highlight the usefulness of lower biosafety level surrogate viruses for such studies. Our results underscore the need to validate inactivation protocols of BSL-4 pathogens using “worst-case scenario” procedures to ensure complete sample inactivation. PMID:27455307
Zhu, Wensheng; Yuan, Ying; Zhang, Jingwen; Zhou, Fan; Knickmeyer, Rebecca C; Zhu, Hongtu
2017-02-01
The aim of this paper is to systematically evaluate a biased sampling issue associated with genome-wide association analysis (GWAS) of imaging phenotypes for most imaging genetic studies, including the Alzheimer's Disease Neuroimaging Initiative (ADNI). Specifically, the original sampling scheme of these imaging genetic studies is primarily the retrospective case-control design, whereas most existing statistical analyses of these studies ignore such sampling scheme by directly correlating imaging phenotypes (called the secondary traits) with genotype. Although it has been well documented in genetic epidemiology that ignoring the case-control sampling scheme can produce highly biased estimates, and subsequently lead to misleading results and suspicious associations, such findings are not well documented in imaging genetics. We use extensive simulations and a large-scale imaging genetic data analysis of the Alzheimer's Disease Neuroimaging Initiative (ADNI) data to evaluate the effects of the case-control sampling scheme on GWAS results based on some standard statistical methods, such as linear regression methods, while comparing it with several advanced statistical methods that appropriately adjust for the case-control sampling scheme. Copyright © 2016 Elsevier Inc. All rights reserved.
Assessment of On-site sanitation system on local groundwater regime in an alluvial aquifer
NASA Astrophysics Data System (ADS)
Quamar, Rafat; Jangam, C.; Veligeti, J.; Chintalapudi, P.; Janipella, R.
2017-12-01
The present study is an attempt to study the impact of the On-site sanitation system on the groundwater sources in its vicinity. The study has been undertaken in the Agra city of Yamuna sub-basin. In this context, sampling sites (3 nos) namely Pandav Nagar, Ayodhya Kunj and Laxmi Nagar were selected for sampling. The groundwater samples were analyzed for major cations, anions and faecal coliform. Critical parameters namely chloride, nitrate and Faecal coliform were considered to assess the impact of the On-site sanitation systems. The analytical results shown that except for chloride, most of the samples exceeded the Bureau of Indian Standard limits for drinking water for all the other analyzed parameters, i.e., nitrate and faecal coliform in the first two sites. In Laxmi Nagar, except for faecal coliform, all the samples are below the BIS limits. In all the three sites, faecal coliform was found in majority of the samples. A comparison of present study indicates that the contamination of groundwater in alluvial setting is less as compared to hard rock where On-site sanitation systems have been implemented.
Preparing for chemical terrorism: stability of injectable atropine sulfate.
Schier, Joshua G; Ravikumar, Padinjarekuttu R; Nelson, Lewis S; Heller, Michael B; Howland, Mary Ann; Hoffman, Robert S
2004-04-01
A massive nerve agent attack may rapidly deplete in-date supplies of atropine. The authors considered using atropine beyond its labeled shelf life. The objective was to determine the stability of premixed injectable atropine sulfate samples with different expiration dates. This was an in-vitro study using gas chromatography and mass spectrometry (GC/MS). Four atropine solutions (labeled concentration of 400 microg/mL) ranging from in date to 12 years beyond expiration (exp) and an additional sample of atropine sulfate (labeled concentration of 2,000 microg/mL) obtained from a World War II era autoinjector were assayed for atropine stability. Standards of atropine sulfate and tropine were prepared and quantified by GC/MS. Study samples were prepared by adding a buffer solution to free the base, extracting with an isopropanol/methylene chloride mixture and followed by evaporating the organic layer to dryness. Pentafluoropropionic anhydride and pentafluoropropanol were then added as derivatization reagents. Study samples were heated, the derivitization reagents were evaporated, and the remaining compound was reconstituted in ethyl acetate for injection into the GC/MS. All solutions were clear and colorless. Atropine concentrations were as follows: in date, 252 microg/mL; 2001 exp, 290 microg/mL; 1999 exp, 314 microg/mL; 1990 exp, 398 microg/mL; and WW II specimen, 1,475 microg/mL. Tropine was found in concentrations of <10 microg/mL in all study samples. Significant amounts of atropine were found in all study samples. All samples remained clear and colorless, and no substantial amount of tropine was found in any study sample. Further testing is needed to determine clinical effect.
Outcome-Dependent Sampling Design and Inference for Cox's Proportional Hazards Model.
Yu, Jichang; Liu, Yanyan; Cai, Jianwen; Sandler, Dale P; Zhou, Haibo
2016-11-01
We propose a cost-effective outcome-dependent sampling design for the failure time data and develop an efficient inference procedure for data collected with this design. To account for the biased sampling scheme, we derive estimators from a weighted partial likelihood estimating equation. The proposed estimators for regression parameters are shown to be consistent and asymptotically normally distributed. A criteria that can be used to optimally implement the ODS design in practice is proposed and studied. The small sample performance of the proposed method is evaluated by simulation studies. The proposed design and inference procedure is shown to be statistically more powerful than existing alternative designs with the same sample sizes. We illustrate the proposed method with an existing real data from the Cancer Incidence and Mortality of Uranium Miners Study.
Machtiger, N A; Fischler, G E; Adams, M C; Spielmaker, R; Graf, J F
2001-01-01
A collaborative study was conducted to test a method developed to distinguish between adequately and inadequately preserved cosmetic formulations. Nineteen laboratories participated in the study. Samples tested included shampoos, hair conditioners, oil-in-water emulsions, and water-in-oil-emulsions. Triplicate samples of 4 adequately preserved and 4 inadequately preserved cosmetic products were tested by each collaborative laboratory. Results showed that all inadequately preserved shampoo and conditioner samples failed to meet the acceptance criteria for adequately preserved formulations. Of the 51 preserved samples, 49 shampoos and 48 conditioners met the criteria for adequate preservation. All samples of inadequately preserved water-in-oil emulsions and oil-in-water emulsions failed to meet the acceptance criteria, whereas all adequately preserved emulsion formulations met the acceptance criteria.
Positron annihilation spectroscopy studies of bronze exposed to sandblasting at different pressure
NASA Astrophysics Data System (ADS)
Kurdyumov, S.; Siemek, K.; Horodek, P.
2017-11-01
An application of Doppler broadening of annihilation line spectroscopy to samples of beryllium bronze DIN-CuBe2 exposed to sandblasting is presented in performed studies. It is familiar that sandblasting introduces open-volume defects. Samples were sandblasted under different pressure for 1 minute using 110 μm particles of Al2O3. For a non-defected sample the constant value of S-parameter was detected. In the cases of sandblasted samples, S-parameter decreased when the depth enhanced. In our studies the thicknesses of defected zones were determined (it was c.a. 30 μm for a sample blasted under pressure of 1 bar and 110 μm - for 5 bar), and it was also observed that if sandblasting pressure is higher the defected zone is larger.
Factor analysis of Wechsler Adult Intelligence Scale-Revised in developmentally disabled persons.
Di Nuovo, Santo F; Buono, Serafino
2006-12-01
The results of previous studies on the factorial structure of Wechsler Intelligence Scales are somewhat inconsistent across normal and pathological samples. To study specific clinical groups, such as developmentally disabled persons, it is useful to examine the factor structure in appropriate samples. A factor analysis was carried out using the principal component method and the Varimax orthogonal rotation on the Wechsler Adult Intelligence Scale (WAIS-R) in a sample of 203 developmentally disabled persons, with a mean age of 25 years 4 months. Developmental disability ranged from mild to moderate. Partially contrasting with previous studies on normal samples, results found a two-factor solution. Wechsler's traditional Verbal and Performance scales seems to be more appropriate for this sample than the alternative three-factor solution.
Mueller, David K.; Spahr, Norman E.
2005-01-01
Introduction: This report is the companion data report for: Nutrients in Streams and Rivers Across the Nation - 1992-2001 (D.K. Mueller and N.E. Spahr, U.S. Geological Survey written commun., 2005). The data contained in this report were collected as part of the National Water-Quality Assessment (NAWQA) Program. Investigations were conducted in 51 large river basins and aquifer systems, which are referred to as 'study units.' Implementation of study-unit investigations were phased so that high-intensity sampling occurred in about one-third of the study units at a time. Investigations in the first 20 study units began in 1991, and stream sampling began in 1992; however, most samples were collected during water years 1993-95. (Water year is defined as the period from October through September and is identified by the year in which it ends.) A second group of 16 study-unit investigations began in 1994, with most of the sampling completed during water years 1996-98. A third group, consisting of 15 study units, began in 1997 with most of the data collected during water years 1999-2001. At some sites, additional sampling continued after the high-intensity time period. Gilliom and others (1995) provide additional information about study-unit sampling design. Additional information about the NAWQA program is available at http://water.usgs.gov/nawqa/index.html.
Comparative analysis of vaginal microbiota sampling using 16S rRNA gene analysis.
Virtanen, Seppo; Kalliala, Ilkka; Nieminen, Pekka; Salonen, Anne
2017-01-01
Molecular methods such as next-generation sequencing are actively being employed to characterize the vaginal microbiota in health and disease. Previous studies have focused on characterizing the biological variation in the microbiota, and less is known about how factors related to sampling contribute to the results. Our aim was to investigate the impact of a sampling device and anatomical sampling site on the quantitative and qualitative outcomes relevant for vaginal microbiota research. We sampled 10 Finnish women representing diverse clinical characteristics with flocked swabs, the Evalyn® self-sampling device, sterile plastic spatulas and a cervical brush that were used to collect samples from fornix, vaginal wall and cervix. Samples were compared on DNA and protein yield, bacterial load, and microbiota diversity and species composition based on Illumina MiSeq sequencing of the 16S rRNA gene. We quantified the relative contributions of sampling variables versus intrinsic variables in the overall microbiota variation, and evaluated the microbiota profiles using several commonly employed metrics such as alpha and beta diversity as well as abundance of major bacterial genera and species. The total DNA yield was strongly dependent on the sampling device and to a lesser extent on the anatomical site of sampling. The sampling strategy did not affect the protein yield or the bacterial load. All tested sampling methods produced highly comparable microbiota profiles based on MiSeq sequencing. The sampling method explained only 2% (p-value = 0.89) of the overall microbiota variation, markedly surpassed by intrinsic factors such as clinical status (microscopy for bacterial vaginosis 53%, p = 0.0001), bleeding (19%, p = 0.0001), and the variation between subjects (11%, p-value 0.0001). The results indicate that different sampling strategies yield comparable vaginal microbiota composition and diversity. Hence, past and future vaginal microbiota studies employing different sampling strategies should be comparable in the absence of other technical confounders. The Evalyn® self-sampling device performed equally well compared to samples taken by a clinician, and hence offers a good-quality microbiota sample without the need for a gynecological examination. The amount of collected sample as well as the DNA and protein yield varied across the sampling techniques, which may have practical implications for study design.
Comparative analysis of vaginal microbiota sampling using 16S rRNA gene analysis
Kalliala, Ilkka; Nieminen, Pekka; Salonen, Anne
2017-01-01
Background Molecular methods such as next-generation sequencing are actively being employed to characterize the vaginal microbiota in health and disease. Previous studies have focused on characterizing the biological variation in the microbiota, and less is known about how factors related to sampling contribute to the results. Our aim was to investigate the impact of a sampling device and anatomical sampling site on the quantitative and qualitative outcomes relevant for vaginal microbiota research. We sampled 10 Finnish women representing diverse clinical characteristics with flocked swabs, the Evalyn® self-sampling device, sterile plastic spatulas and a cervical brush that were used to collect samples from fornix, vaginal wall and cervix. Samples were compared on DNA and protein yield, bacterial load, and microbiota diversity and species composition based on Illumina MiSeq sequencing of the 16S rRNA gene. We quantified the relative contributions of sampling variables versus intrinsic variables in the overall microbiota variation, and evaluated the microbiota profiles using several commonly employed metrics such as alpha and beta diversity as well as abundance of major bacterial genera and species. Results The total DNA yield was strongly dependent on the sampling device and to a lesser extent on the anatomical site of sampling. The sampling strategy did not affect the protein yield or the bacterial load. All tested sampling methods produced highly comparable microbiota profiles based on MiSeq sequencing. The sampling method explained only 2% (p-value = 0.89) of the overall microbiota variation, markedly surpassed by intrinsic factors such as clinical status (microscopy for bacterial vaginosis 53%, p = 0.0001), bleeding (19%, p = 0.0001), and the variation between subjects (11%, p-value 0.0001). Conclusions The results indicate that different sampling strategies yield comparable vaginal microbiota composition and diversity. Hence, past and future vaginal microbiota studies employing different sampling strategies should be comparable in the absence of other technical confounders. The Evalyn® self-sampling device performed equally well compared to samples taken by a clinician, and hence offers a good-quality microbiota sample without the need for a gynecological examination. The amount of collected sample as well as the DNA and protein yield varied across the sampling techniques, which may have practical implications for study design. PMID:28723942
Mars sample return: Site selection and sample acquisition study
NASA Technical Reports Server (NTRS)
Nickle, N. (Editor)
1980-01-01
Various vehicle and mission options were investigated for the continued exploration of Mars; the cost of a minimum sample return mission was estimated; options and concepts were synthesized into program possibilities; and recommendations for the next Mars mission were made to the Planetary Program office. Specific sites and all relevant spacecraft and ground-based data were studied in order to determine: (1) the adequacy of presently available data for identifying landing sities for a sample return mission that would assure the acquisition of material from the most important geologic provinces of Mars; (2) the degree of surface mobility required to assure sample acquisition for these sites; (3) techniques to be used in the selection and drilling of rock a samples; and (4) the degree of mobility required at the two Viking sites to acquire these samples.
Generalized Ensemble Sampling of Enzyme Reaction Free Energy Pathways
Wu, Dongsheng; Fajer, Mikolai I.; Cao, Liaoran; Cheng, Xiaolin; Yang, Wei
2016-01-01
Free energy path sampling plays an essential role in computational understanding of chemical reactions, particularly those occurring in enzymatic environments. Among a variety of molecular dynamics simulation approaches, the generalized ensemble sampling strategy is uniquely attractive for the fact that it not only can enhance the sampling of rare chemical events but also can naturally ensure consistent exploration of environmental degrees of freedom. In this review, we plan to provide a tutorial-like tour on an emerging topic: generalized ensemble sampling of enzyme reaction free energy path. The discussion is largely focused on our own studies, particularly ones based on the metadynamics free energy sampling method and the on-the-path random walk path sampling method. We hope that this mini presentation will provide interested practitioners some meaningful guidance for future algorithm formulation and application study. PMID:27498634
A Sample Handling System for Mars Sample Return - Design and Status
NASA Astrophysics Data System (ADS)
Allouis, E.; Renouf, I.; Deridder, M.; Vrancken, D.; Gelmi, R.; Re, E.
2009-04-01
A mission to return atmosphere and soil samples form the Mars is highly desired by planetary scientists from around the world and space agencies are starting preparation for the launch of a sample return mission in the 2020 timeframe. Such a mission would return approximately 500 grams of atmosphere, rock and soil samples to Earth by 2025. Development of a wide range of new technology will be critical to the successful implementation of such a challenging mission. Technical developments required to realise the mission include guided atmospheric entry, soft landing, sample handling robotics, biological sealing, Mars atmospheric ascent sample rendezvous & capture and Earth return. The European Space Agency has been performing system definition studies along with numerous technology development studies under the framework of the Aurora programme. Within the scope of these activities Astrium has been responsible for defining an overall sample handling architecture in collaboration with European partners (sample acquisition and sample capture, Galileo Avionica; sample containment and automated bio-sealing, Verhaert). Our work has focused on the definition and development of the robotic systems required to move the sample through the transfer chain. This paper presents the Astrium team's high level design for the surface transfer system and the orbiter transfer system. The surface transfer system is envisaged to use two robotic arms of different sizes to allow flexible operations and to enable sample transfer over relatively large distances (~2 to 3 metres): The first to deploy/retract the Drill Assembly used for sample collection, the second for the transfer of the Sample Container (the vessel containing all the collected samples) from the Drill Assembly to the Mars Ascent Vehicle (MAV). The sample transfer actuator also features a complex end-effector for handling the Sample Container. The orbiter transfer system will transfer the Sample Container from the capture mechanism through a bio-sealing system to the Earth Return Capsule (ERC) and has distinctly different requirements from the surface transfer system. The operations required to transfer the samples to the ERC are clearly defined and make use of mechanisms specifically designed for the job rather than robotic arms. Though it is mechanical rather than robotic, the design of the orbiter transfer system is very complex in comparison to most previous missions to fulfil all the scientific and technological requirements. Further mechanisms will be required to lock the samples into the ERC and to close the door at the rear of the ERC through which the samples have been inserted. Having performed this overall definition study, Astrium is now leading the next step of the development of the MSR sample handling: the Mars Surface Sample Transfer and Manipulation project (MSSTM). Organised in two phases, the project will re-evaluate in phase 1 the output of the previous study in the light of new inputs (e.g. addition of a rover) and investigate further the architectures and systems involved in the sample transfer chain while identifying the critical technologies. The second phase of the project will concentrate on the prototyping of a number of these key technologies with the goal of providing an end-to end validation of the surface sample transfer concept.
Development of sampling plans for cotton bolls injured by stink bugs (Hemiptera: Pentatomidae).
Reay-Jones, F P F; Toews, M D; Greene, J K; Reeves, R B
2010-04-01
Cotton, Gossypium hirsutum L., bolls were sampled in commercial fields for stink bug (Hemiptera: Pentatomidae) injury during 2007 and 2008 in South Carolina and Georgia. Across both years of this study, boll-injury percentages averaged 14.8 +/- 0.3 (SEM). At average boll injury treatment levels of 10, 20, 30, and 50%, the percentage of samples with at least one injured boll was 82, 97, 100, and 100%, respectively. Percentage of field-sampling date combinations with average injury < 10, 20, 30, and 50% was 35, 80, 95, and 99%, respectively. At the average of 14.8% boll injury or 2.9 injured bolls per 20-boll sample, 112 samples at Dx = 0.1 (within 10% of the mean) were required for population estimation, compared with only 15 samples at Dx = 0.3. Using a sample size of 20 bolls, our study indicated that, at the 10% threshold and alpha = beta = 0.2 (with 80% confidence), control was not needed when <1.03 bolls were injured. The sampling plan required continued sampling for a range of 1.03-3.8 injured bolls per 20-boll sample. Only when injury was > 3.8 injured bolls per 20-boll sample was a control measure needed. Sequential sampling plans were also determined for thresholds of 20, 30, and 50% injured bolls. Sample sizes for sequential sampling plans were significantly reduced when compared with a fixed sampling plan (n=10) for all thresholds and error rates.
2014-01-01
Background The use of biological samples in research raises a number of ethical issues in relation to consent, storage, export, benefit sharing and re-use of samples. Participant perspectives have been explored in North America and Europe, with only a few studies reported in Africa. The amount of research being conducted in Africa is growing exponentially with volumes of biological samples being exported from the African continent. In order to investigate the perspectives of African research participants, we conducted a study at research sites in the Western Cape and Gauteng, South Africa. Methods Data were collected using a semi-structured questionnaire that captured both quantitative and qualitative information at 6 research sites in South Africa. Interviews were conducted in English and Afrikaans. Data were analysed both quantitatively and qualitatively. Results Our study indicates that while the majority of participants were supportive of providing samples for research, serious concerns were voiced about future use, benefit sharing and export of samples. While researchers view the provision of biosamples as a donation, participants believe that they still have ownership rights and are therefore in favour of benefit sharing. Almost half of the participants expressed a desire to be re-contacted for consent for future use of their samples. Interesting opinions were expressed with respect to export of samples. Conclusions Eliciting participant perspectives is an important part of community engagement in research involving biological sample collection, export, storage and future use. A tiered consent process appears to be more acceptable to participants in this study. Eliciting opinions of researchers and research ethics committee (REC) members would contribute multiple perspectives. Further research is required to interrogate the concept of ownership and the consent process in research involving biological samples. PMID:24447822
Drinking water quality assessment.
Aryal, J; Gautam, B; Sapkota, N
2012-09-01
Drinking water quality is the great public health concern because it is a major risk factor for high incidence of diarrheal diseases in Nepal. In the recent years, the prevalence rate of diarrhoea has been found the highest in Myagdi district. This study was carried out to assess the quality of drinking water from different natural sources, reservoirs and collection taps at Arthunge VDC of Myagdi district. A cross-sectional study was carried out using random sampling method in Arthunge VDC of Myagdi district from January to June,2010. 84 water samples representing natural sources, reservoirs and collection taps from the study area were collected. The physico-chemical and microbiological analysis was performed following standards technique set by APHA 1998 and statistical analysis was carried out using SPSS 11.5. The result was also compared with national and WHO guidelines. Out of 84 water samples (from natural source, reservoirs and tap water) analyzed, drinking water quality parameters (except arsenic and total coliform) of all water samples was found to be within the WHO standards and national standards.15.48% of water samples showed pH (13) higher than the WHO permissible guideline values. Similarly, 85.71% of water samples showed higher Arsenic value (72) than WHO value. Further, the statistical analysis showed no significant difference (P<0.05) of physico-chemical parameters and total coliform count of drinking water for collection taps water samples of winter (January, 2010) and summer (June, 2010). The microbiological examination of water samples revealed the presence of total coliform in 86.90% of water samples. The results obtained from physico-chemical analysis of water samples were within national standard and WHO standards except arsenic. The study also found the coliform contamination to be the key problem with drinking water.
Allen, John C; Thumboo, Julian; Lye, Weng Kit; Conaghan, Philip G; Chew, Li-Ching; Tan, York Kiat
2018-03-01
To determine whether novel methods of selecting joints through (i) ultrasonography (individualized-ultrasound [IUS] method), or (ii) ultrasonography and clinical examination (individualized-composite-ultrasound [ICUS] method) translate into smaller rheumatoid arthritis (RA) clinical trial sample sizes when compared to existing methods utilizing predetermined joint sites for ultrasonography. Cohen's effect size (ES) was estimated (ES^) and a 95% CI (ES^L, ES^U) calculated on a mean change in 3-month total inflammatory score for each method. Corresponding 95% CIs [nL(ES^U), nU(ES^L)] were obtained on a post hoc sample size reflecting the uncertainty in ES^. Sample size calculations were based on a one-sample t-test as the patient numbers needed to provide 80% power at α = 0.05 to reject a null hypothesis H 0 : ES = 0 versus alternative hypotheses H 1 : ES = ES^, ES = ES^L and ES = ES^U. We aimed to provide point and interval estimates on projected sample sizes for future studies reflecting the uncertainty in our study ES^S. Twenty-four treated RA patients were followed up for 3 months. Utilizing the 12-joint approach and existing methods, the post hoc sample size (95% CI) was 22 (10-245). Corresponding sample sizes using ICUS and IUS were 11 (7-40) and 11 (6-38), respectively. Utilizing a seven-joint approach, the corresponding sample sizes using ICUS and IUS methods were nine (6-24) and 11 (6-35), respectively. Our pilot study suggests that sample size for RA clinical trials with ultrasound endpoints may be reduced using the novel methods, providing justification for larger studies to confirm these observations. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.
Osimani, Andrea; Cardinali, Federica; Aquilanti, Lucia; Garofalo, Cristiana; Roncolini, Andrea; Milanović, Vesna; Pasquini, Marina; Tavoletti, Stefano; Clementi, Francesca
2017-12-18
The present study aimed to assess the occurrence of transferable determinants conferring resistance to tetracyclines, macrolide-lincosamide-streptogramin B, vancomycin, beta-lactams, and aminoglycosides in 40 samples of commercialized edible mealworms (Tenebrio molitor L.) purchased from European Union (EU) and non-EU producers. A high prevalence of tet(K) was observed in all of the samples assayed, with percentages of PCR-based positivity that ranged from 80% (samples from Thailand) to 100% (samples from the Netherlands, Belgium and France). For macrolides, erm(B) prevailed, being detected in 57.5% of the samples assayed, whereas erm(A) and erm(C) were detected with lower frequencies. Genes for resistance to vancomycin were only detected in samples produced in France and Belgium, with 90% and 10% of the samples being positive for vanA, respectively. Beta-lactamase genes were found with low occurrence, whereas the gene aac-aph, conferring high resistance to aminoglycosides, was found in 40% of the samples produced in the Netherlands and Belgium and 20% of the samples produced in Thailand. The results of Principal Coordinate Analysis and Principal Component Analysis depicted a clean separation of the samples collected from the four producers based on the distribution of the 12 AR determinants considered. Given the growing interest on the use of mealworms as a novel protein source, AR detection frequencies found in the present study suggest further investigation into the use of antibiotics during rearing of this insect species and more extensive studies focused on the factors that can affect the diffusion of transferable ARs in the production chain. Until such studies are completed, prudent use of antibiotics during rearing of edible insects is recommended. Copyright © 2017 Elsevier B.V. All rights reserved.
The association between intelligence and lifespan is mostly genetic.
Arden, Rosalind; Luciano, Michelle; Deary, Ian J; Reynolds, Chandra A; Pedersen, Nancy L; Plassman, Brenda L; McGue, Matt; Christensen, Kaare; Visscher, Peter M
2016-02-01
Several studies in the new field of cognitive epidemiology have shown that higher intelligence predicts longer lifespan. This positive correlation might arise from socioeconomic status influencing both intelligence and health; intelligence leading to better health behaviours; and/or some shared genetic factors influencing both intelligence and health. Distinguishing among these hypotheses is crucial for medicine and public health, but can only be accomplished by studying a genetically informative sample. We analysed data from three genetically informative samples containing information on intelligence and mortality: Sample 1, 377 pairs of male veterans from the NAS-NRC US World War II Twin Registry; Sample 2, 246 pairs of twins from the Swedish Twin Registry; and Sample 3, 784 pairs of twins from the Danish Twin Registry. The age at which intelligence was measured differed between the samples. We used three methods of genetic analysis to examine the relationship between intelligence and lifespan: we calculated the proportion of the more intelligent twins who outlived their co-twin; we regressed within-twin-pair lifespan differences on within-twin-pair intelligence differences; and we used the resulting regression coefficients to model the additive genetic covariance. We conducted a meta-analysis of the regression coefficients across the three samples. The combined (and all three individual samples) showed a small positive phenotypic correlation between intelligence and lifespan. In the combined sample observed r = .12 (95% confidence interval .06 to .18). The additive genetic covariance model supported a genetic relationship between intelligence and lifespan. In the combined sample the genetic contribution to the covariance was 95%; in the US study, 84%; in the Swedish study, 86%, and in the Danish study, 85%. The finding of common genetic effects between lifespan and intelligence has important implications for public health, and for those interested in the genetics of intelligence, lifespan or inequalities in health outcomes including lifespan. © The Author 2015; Published by Oxford University Press on behalf of the International Epidemiological Association.
The UK Biobank sample handling and storage validation studies.
Peakman, Tim C; Elliott, Paul
2008-04-01
and aims UK Biobank is a large prospective study in the United Kingdom to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. It involves the collection of blood and urine from 500 000 individuals aged between 40 and 69 years. How the samples are collected, processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. A series of validation studies was recommended to test the robustness of the draft sample handling and storage protocol. Samples of blood and urine were collected from 40 healthy volunteers and either processed immediately according to the protocol or maintained at specified temperatures (4 degrees C for all tubes with the exception of vacutainers containing acid citrate dextrose that were maintained at 18 degrees C) for 12, 24 or 36 h prior to processing. A further sample was maintained for 24 h at 4 degrees C, processed and the aliquots frozen at -80 degrees C for 20 days and then thawed under controlled conditions. The stability of the samples was compared for the different times in a wide variety of assays. The samples maintained at 4 degrees C were stable for at least 24 h after collection for a wide range of assays. Small but significant changes were observed in metabonomic studies in samples maintained at 4 degrees C for 36 h. There was no degradation of the samples for a range of biochemical assays after short-term freezing and thawing under controlled conditions. Whole blood maintained at 18 degrees C for 24 h in vacutainers containing acid citrate dextrose is suitable for viral immortalization techniques. The validation studies reported in this supplement provide justification for the sample handling and storage procedures adopted in the UK Biobank project.
The association between intelligence and lifespan is mostly genetic
Arden, Rosalind; Deary, Ian J; Reynolds, Chandra A; Pedersen, Nancy L; Plassman, Brenda L; McGue, Matt; Christensen, Kaare; Visscher, Peter M
2016-01-01
Abstract Background: Several studies in the new field of cognitive epidemiology have shown that higher intelligence predicts longer lifespan. This positive correlation might arise from socioeconomic status influencing both intelligence and health; intelligence leading to better health behaviours; and/or some shared genetic factors influencing both intelligence and health. Distinguishing among these hypotheses is crucial for medicine and public health, but can only be accomplished by studying a genetically informative sample. Methods: We analysed data from three genetically informative samples containing information on intelligence and mortality: Sample 1, 377 pairs of male veterans from the NAS-NRC US World War II Twin Registry; Sample 2, 246 pairs of twins from the Swedish Twin Registry; and Sample 3, 784 pairs of twins from the Danish Twin Registry. The age at which intelligence was measured differed between the samples. We used three methods of genetic analysis to examine the relationship between intelligence and lifespan: we calculated the proportion of the more intelligent twins who outlived their co-twin; we regressed within-twin-pair lifespan differences on within-twin-pair intelligence differences; and we used the resulting regression coefficients to model the additive genetic covariance. We conducted a meta-analysis of the regression coefficients across the three samples. Results: The combined (and all three individual samples) showed a small positive phenotypic correlation between intelligence and lifespan. In the combined sample observed r = .12 (95% confidence interval .06 to .18). The additive genetic covariance model supported a genetic relationship between intelligence and lifespan. In the combined sample the genetic contribution to the covariance was 95%; in the US study, 84%; in the Swedish study, 86%, and in the Danish study, 85%. Conclusions: The finding of common genetic effects between lifespan and intelligence has important implications for public health, and for those interested in the genetics of intelligence, lifespan or inequalities in health outcomes including lifespan. PMID:26213105
Lim, Hazel Sin Yue; Zheng, Qianwang; Miks-Krajnik, Marta; Turner, Matthew; Yuk, Hyun-Gyun
2015-06-01
The objective of this study was to evaluate performance of the commercial kit based on loop-mediated isothermal amplification (LAMP) in comparison with the International Organization for Standardization method for detecting uninjured and sublethally injured Salmonella cells artificially inoculated at levels of 10(0) and 10(1) CFU/25 g on raw duck wing, raw mung bean sprouts, and processed fishballs. Injured cells were prepared by a heat treatment for duck wings and fishball samples and a chlorine treatment for bean sprout samples. Additionally, a validation study was performed on naturally contaminated food samples sold in Singapore. A total of 110 samples of each commodity were analyzed in this study. Regardless of inoculum levels, the detection by the commercial LAMP kit showed 100% sensitivity and specificity for both inoculated and uninoculated samples compared with the International Organization for Standardization method, with the exception of bean sprout samples. Only 20% of bean sprout samples inoculated with 10(0) CFU/25 g injured Salmonella cells were positive by using the commercial LAMP-based kit. However, all negative samples became positive following a secondary enrichment in Rappaport-Vassiliadis medium with soy broth or after concentration by centrifugation. These results suggest that secondary enrichment or centrifugation should be considered as an additional step to increase the sensitivity of the commercial LAMP-based kit with low numbers of injured target cells in samples with high background microflora (such as mung bean sprouts). The validation study also showed that the commercial LAMP-based kit provided 91% sensitivity and 95% specificity for naturally contaminated samples. Thus, this study demonstrates that the commercial LAMP-based kit might be a cost-effective method, as this system could provide rapid, accurate detection of both uninjured and injured Salmonella cells on raw duck wings, raw mung bean sprouts, and processed fishballs in less than 26 h.
A high pressure modulated molecular beam mass spectrometric sampling system
NASA Technical Reports Server (NTRS)
Stearns, C. A.; Kohl, F. J.; Fryburg, G. C.; Miller, R. A.
1977-01-01
The current state of understanding of free-jet high pressure sampling is critically reviewed and modifications of certain theoretical and empirical considerations are presented. A high pressure, free-jet expansion, modulated molecular beam, mass spectrometric sampling apparatus was constructed and this apparatus is described in detail. Experimental studies have demonstrated that the apparatus can be used to sample high temperature systems at pressures up to one atmosphere. Condensible high temperature gaseous species have been routinely sampled and the mass spectrometric detector has provided direct identification of sampled species. System sensitivity is better than one tenth of a part per million. Experimental results obtained with argon and nitrogen beams are presented and compared to theoretical predictions. These results and the respective comparison are taken to indicate acceptable performance of the sampling apparatus. Results are also given for two groups of experiments related to hot corrosion studies. The formation of gaseous sodium sulfate in doped methane-oxygen flames was characterized and the oxidative vaporization of metals was studied in an atmospheric pressure flowing gas system to which gaseous salt partial pressures were added.
Detection of Campylobacter in human faecal samples in Fiji.
Devi, Aruna; Wilkinson, Jenny; Mahony, Timothy; Vanniasinkam, Thiru
2014-01-01
Data on campylobacteriosis in developed countries are well documented; in contrast, few studies on campylobacteriosis have been conducted in developing countries. This study was undertaken to test for Campylobacter in human faecal samples sent to the two major pathology laboratories in Fiji. A total of 408 diarrhoeal faecal samples were collected from the two major hospital pathology laboratories in Central Fiji (Suva) and Western Fiji (Lautoka) between December 2012 and February 2013 and from June to July 2013. Samples were analysed for the presence of Campylobacter using polymerase chain reaction (PCR) based methods. Campylobacter was detected in 241/408 (59.1%) of samples tested using PCR. Samples from children aged less than five accounted for 21.6% of positive cases. Campylobacter was detected in 59.1% of diarrhoeal samples collected from the two main laboratories in Fiji. A high proportion of children under five years with Campylobacter has been reported in other countries and could be due to parents being more likely to seek medical attention. Further studies are required to confirm the species of Campylobacter that are predominantly associated with gastroenteritis in Fiji.
An audit of the statistics and the comparison with the parameter in the population
NASA Astrophysics Data System (ADS)
Bujang, Mohamad Adam; Sa'at, Nadiah; Joys, A. Reena; Ali, Mariana Mohamad
2015-10-01
The sufficient sample size that is needed to closely estimate the statistics for particular parameters are use to be an issue. Although sample size might had been calculated referring to objective of the study, however, it is difficult to confirm whether the statistics are closed with the parameter for a particular population. All these while, guideline that uses a p-value less than 0.05 is widely used as inferential evidence. Therefore, this study had audited results that were analyzed from various sub sample and statistical analyses and had compared the results with the parameters in three different populations. Eight types of statistical analysis and eight sub samples for each statistical analysis were analyzed. Results found that the statistics were consistent and were closed to the parameters when the sample study covered at least 15% to 35% of population. Larger sample size is needed to estimate parameter that involve with categorical variables compared with numerical variables. Sample sizes with 300 to 500 are sufficient to estimate the parameters for medium size of population.
Blekhman, Ran; Tang, Karen; Archie, Elizabeth A; Barreiro, Luis B; Johnson, Zachary P; Wilson, Mark E; Kohn, Jordan; Yuan, Michael L; Gesquiere, Laurence; Grieneisen, Laura E; Tung, Jenny
2016-08-16
Field studies of wild vertebrates are frequently associated with extensive collections of banked fecal samples-unique resources for understanding ecological, behavioral, and phylogenetic effects on the gut microbiome. However, we do not understand whether sample storage methods confound the ability to investigate interindividual variation in gut microbiome profiles. Here, we extend previous work on storage methods for gut microbiome samples by comparing immediate freezing, the gold standard of preservation, to three methods commonly used in vertebrate field studies: lyophilization, storage in ethanol, and storage in RNAlater. We found that the signature of individual identity consistently outweighed storage effects: alpha diversity and beta diversity measures were significantly correlated across methods, and while samples often clustered by donor, they never clustered by storage method. Provided that all analyzed samples are stored the same way, banked fecal samples therefore appear highly suitable for investigating variation in gut microbiota. Our results open the door to a much-expanded perspective on variation in the gut microbiome across species and ecological contexts.
Prevalence of hepatitis C virus (HCV) genotypes in Balochistan.
Afridi, Sarwat; Naeem, Muhammad; Hussain, Abid; Kakar, Naseebullah; Babar, Masroor Ellahi; Ahmad, Jamil
2009-07-01
A molecular study was conducted to investigate the prevalence of Hepatitis C virus genotypes in HCV infected population of Balochistan. Forty HCV seropositive samples belonging to seven different locations of Balochistan were collected from different health care centres. Qualitative analysis of these samples using PCR resulted in 28 positive samples. The PCR positive samples were subjected to genotyping using the method described by Ohno et al (J Clin Microbiol 35:201-202, 1997) with minor modifications. Genotyping of 28 samples revealed three different genotypes including 3a, 3b and 1a. The most prevalent genotype was 3a with rate of 50% followed by genotype 3b and 1a, respectively. Nine samples remained untyped, suggesting the need of further investigation of genotypes in this region. It has been proposed that sequencing of these samples may be helpful to unreveal these genotypes and further epidemiology of HCV genotypes. Further more, extensive and large scale studies are needed to understand the epidemiology of HCV genotypes, as no such study has been carried in this province.
Palmer, C.A.; Lyons, P.C.
1990-01-01
Twelve hand-picked vitrinite concentrates and companion whole-coal samples were analyzed for trace and minor elements by instrumental neutron activation analysis (INAA) and direct-current-arc spectrographic techniques (DCAS). The vitrinite concentrates contained 94 to nearly 100 vol.% vitrinite compared to 71-95 vol.% in the companion whole coals. The ash contents of the vitrinite concentrates were 2 to more than 190 times less than the ash contents of the companion whole coals. Organic and inorganic affinities were determined by comparing the elemental concentrations in the vitrinite concentrates to the concentrations in the companion whole coals. The ratios of these concentrations for 33 selected elements are shown in Figure 1. Ratios greater than 1 indicate organic affinity, and ratios less than 1 indicate inorganic affinity. Br and W generally showed organic affinity in all samples in this study. In the nine samples from the eastern United States (Fig. 1A-C) less than one-fourth of the trace elements show organic affinity compared to nearly one-half for the three English and Australian samples (Fig. 1D). The elements that generally show organic affinity in the non-U.S.A. samples studied include As, Cs, Hf, and Ni, which have generally inorganic affinities in the U.S.A. samples, and Cr, Sb, Se, and U, which have mixed (both organic and inorganic) affinities, in the U.S.A. coals studied, has an inorganic affinity in the English coals studied. B shows organic affinity in the samples from the Illinois basin (Fig. 1C). For the samples studied, Ba shows organic affinity in the Appalachian basin bituminous coals (Fig. 1B), inorganic affinity in the Illinois basin coals, and overall mixed affinities. In all the samples studied, Cu, Mn, Na, Sr, Ta, V, and Zn show mixed affinities, and A1, Co, Eu, Fe, Ga, K, La, Mg, Sc, Si, Th, Ti, and Ub have generally inorganic affinity. ?? 1990.
Mars Sample Return Architecture Assessment Study
NASA Astrophysics Data System (ADS)
Centuori, S.; Hermosín, P.; Martín, J.; De Zaiacomo, G.; Colin, S.; Godfrey, A.; Myles, J.; Johnson, H.; Sachdev, T.; Ahmed, R.
2018-04-01
Current paper presents the results of ESA funded activity "Mars Sample Return Architecture Assessment Study" carried-out by DEIMOS Space, Lockheed Martin UK Ampthill, and MDA Corporation, where more than 500 mission design options have been studied.
Berlinger, Balazs; Harper, Martin
2018-02-01
There is interest in the bioaccessible metal components of aerosols, but this has been minimally studied because standardized sampling and analytical methods have not yet been developed. An interlaboratory study (ILS) has been carried out to evaluate a method for determining the water-soluble component of realistic welding fume (WF) air samples. Replicate samples were generated in the laboratory and distributed to participating laboratories to be analyzed according to a standardized procedure. Within-laboratory precision of replicate sample analysis (repeatability) was very good. Reproducibility between laboratories was not as good, but within limits of acceptability for the analysis of typical aerosol samples. These results can be used to support the development of a standardized test method.
Mass load estimation errors utilizing grab sampling strategies in a karst watershed
Fogle, A.W.; Taraba, J.L.; Dinger, J.S.
2003-01-01
Developing a mass load estimation method appropriate for a given stream and constituent is difficult due to inconsistencies in hydrologic and constituent characteristics. The difficulty may be increased in flashy flow conditions such as karst. Many projects undertaken are constrained by budget and manpower and do not have the luxury of sophisticated sampling strategies. The objectives of this study were to: (1) examine two grab sampling strategies with varying sampling intervals and determine the error in mass load estimates, and (2) determine the error that can be expected when a grab sample is collected at a time of day when the diurnal variation is most divergent from the daily mean. Results show grab sampling with continuous flow to be a viable data collection method for estimating mass load in the study watershed. Comparing weekly, biweekly, and monthly grab sampling, monthly sampling produces the best results with this method. However, the time of day the sample is collected is important. Failure to account for diurnal variability when collecting a grab sample may produce unacceptable error in mass load estimates. The best time to collect a sample is when the diurnal cycle is nearest the daily mean.
Wei, Binnian; Feng, June; Rehmani, Imran J; Miller, Sharyn; McGuffey, James E; Blount, Benjamin C; Wang, Lanqing
2014-09-25
Most sample preparation methods characteristically involve intensive and repetitive labor, which is inefficient when preparing large numbers of samples from population-scale studies. This study presents a robotic system designed to meet the sampling requirements for large population-scale studies. Using this robotic system, we developed and validated a method to simultaneously measure urinary anatabine, anabasine, nicotine and seven major nicotine metabolites: 4-Hydroxy-4-(3-pyridyl)butanoic acid, cotinine-N-oxide, nicotine-N-oxide, trans-3'-hydroxycotinine, norcotinine, cotinine and nornicotine. We analyzed robotically prepared samples using high-performance liquid chromatography (HPLC) coupled with triple quadrupole mass spectrometry in positive electrospray ionization mode using scheduled multiple reaction monitoring (sMRM) with a total runtime of 8.5 min. The optimized procedure was able to deliver linear analyte responses over a broad range of concentrations. Responses of urine-based calibrators delivered coefficients of determination (R(2)) of >0.995. Sample preparation recovery was generally higher than 80%. The robotic system was able to prepare four 96-well plate (384 urine samples) per day, and the overall method afforded an accuracy range of 92-115%, and an imprecision of <15.0% on average. The validation results demonstrate that the method is accurate, precise, sensitive, robust, and most significantly labor-saving for sample preparation, making it efficient and practical for routine measurements in large population-scale studies such as the National Health and Nutrition Examination Survey (NHANES) and the Population Assessment of Tobacco and Health (PATH) study. Published by Elsevier B.V.
The Study on Mental Health at Work: Design and sampling.
Rose, Uwe; Schiel, Stefan; Schröder, Helmut; Kleudgen, Martin; Tophoven, Silke; Rauch, Angela; Freude, Gabriele; Müller, Grit
2017-08-01
The Study on Mental Health at Work (S-MGA) generates the first nationwide representative survey enabling the exploration of the relationship between working conditions, mental health and functioning. This paper describes the study design, sampling procedures and data collection, and presents a summary of the sample characteristics. S-MGA is a representative study of German employees aged 31-60 years subject to social security contributions. The sample was drawn from the employment register based on a two-stage cluster sampling procedure. Firstly, 206 municipalities were randomly selected from a pool of 12,227 municipalities in Germany. Secondly, 13,590 addresses were drawn from the selected municipalities for the purpose of conducting 4500 face-to-face interviews. The questionnaire covers psychosocial working and employment conditions, measures of mental health, work ability and functioning. Data from personal interviews were combined with employment histories from register data. Descriptive statistics of socio-demographic characteristics and logistic regressions analyses were used for comparing population, gross sample and respondents. In total, 4511 face-to-face interviews were conducted. A test for sampling bias revealed that individuals in older cohorts participated more often, while individuals with an unknown educational level, residing in major cities or with a non-German ethnic background were slightly underrepresented. There is no indication of major deviations in characteristics between the basic population and the sample of respondents. Hence, S-MGA provides representative data for research on work and health, designed as a cohort study with plans to rerun the survey 5 years after the first assessment.
Jamsen, Kris M; Duffull, Stephen B; Tarning, Joel; Lindegardh, Niklas; White, Nicholas J; Simpson, Julie A
2012-07-11
Artemisinin-based combination therapy (ACT) is currently recommended as first-line treatment for uncomplicated malaria, but of concern, it has been observed that the effectiveness of the main artemisinin derivative, artesunate, has been diminished due to parasite resistance. This reduction in effect highlights the importance of the partner drugs in ACT and provides motivation to gain more knowledge of their pharmacokinetic (PK) properties via population PK studies. Optimal design methodology has been developed for population PK studies, which analytically determines a sampling schedule that is clinically feasible and yields precise estimation of model parameters. In this work, optimal design methodology was used to determine sampling designs for typical future population PK studies of the partner drugs (mefloquine, lumefantrine, piperaquine and amodiaquine) co-administered with artemisinin derivatives. The optimal designs were determined using freely available software and were based on structural PK models from the literature and the key specifications of 100 patients with five samples per patient, with one sample taken on the seventh day of treatment. The derived optimal designs were then evaluated via a simulation-estimation procedure. For all partner drugs, designs consisting of two sampling schedules (50 patients per schedule) with five samples per patient resulted in acceptable precision of the model parameter estimates. The sampling schedules proposed in this paper should be considered in future population pharmacokinetic studies where intensive sampling over many days or weeks of follow-up is not possible due to either ethical, logistic or economical reasons.
NASA Astrophysics Data System (ADS)
Liger, Lucie; Margoum, Christelle; Guillemain, Céline; Carluer, Nadia
2014-05-01
The implementation of the WFD (Water Framework Directive), requests European Union member states to achieve good qualitative and quantitative status of all water bodies in 2015. The monitoring of organic micropollutants such as pesticides is an essential step to assess the chemical and biological state of streams, to understand the reasons of degradation and to implement sound mitigation solutions in the watershed. In particular, the water sampling, which can be performed according to several strategies, has to be closely adapted to the experimental goals. In this study, we present and compare 3 different active sampling strategies: grab sampling, time-related and flow-dependent automatic samplings. In addition, the last two can be fractionated (i.e., several samples collected, and each one contained in a single bottle) or averaged (i.e., several samples mixed in the same bottle). Time-related samples allow the assessment of average exposure concentrations of organic micropollutants, whereas flow-dependent samples lead to average flux concentrations. The 3 sampling strategies were applied and compared during the monitoring of the pesticide contamination of a river located in a French vineyard watershed (the Morcille River, located 60 km north of Lyon, in the Beaujolais region). Data were collected between 2007 and 2011, during different seasons and for a range of hydrological events. The Morcille watershed is characterized by contrasted hydrological events with a very short-time response due to its small size (5 km²), steep slopes (20 to 28%) and highly permeable sandy soils. These features make it particularly difficult to monitor water quality, due to fast variations of pesticide concentrations depending on rain events. This comparative study is performed in 2 steps. At first, we compare the timestamps of each sample composing the weekly-averaged samples and those of the grab samples with hydrological data. This allows us to evaluate the efficiency of these 2 sampling strategies in the integration of flow variations and therefore pesticide concentration variations during the sampling campaign. In a second step, we use the fractionated samples data during flood events to calculate the concentrations of virtual averaged samples of the events. Different time or flow steps were used for the calculation, to assess their impact on the pesticide averaged-concentrations or fluxes. These analyses highlight the benefits and drawbacks of each sampling strategy. They show that the sampling strategy should be carefully chosen and designed depending on the final aim of the study and on the watershed characteristics (in particular its hydrological dynamics). This study may help to design future monitoring on water quality. Key Words: sampling strategies, surface water, concentration, flux, pesticides.
ERIC Educational Resources Information Center
Becker, Sharon J.
2017-01-01
The purpose of this study was to investigate the English learning of a sample of students who are deaf or hard of hearing and English learners (DHH EL) and a sample of students who are English learners (EL). The English language learning of four students who were DHH EL and four students who were EL was explored through a multiple-case study using…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erickson, M.S.; Gent, C.A.; Bradley, L.A.
1989-01-01
A U.S. Geological Survey report detailing the analytical results and sample locality maps of stream-sediment, heavy-mineral-concentrate, and rock samples from the Little Jacks Creek, Big Jacks Creek, Duncan Creek, and Upper Deep Creek Wilderness Study Areas, Owyhee County, Idaho
Blood Sampling and Preparation Procedures for Proteomic Biomarker Studies of Psychiatric Disorders.
Guest, Paul C; Rahmoune, Hassan
2017-01-01
A major challenge in proteomic biomarker discovery and validation for psychiatric diseases is the inherent biological complexity underlying these conditions. There are also many technical issues which hinder this process such as the lack of standardization in sampling, processing and storage of bio-samples in preclinical and clinical settings. This chapter describes a reproducible procedure for sampling blood serum and plasma that is specifically designed for maximizing data quality output in two-dimensional gel electrophoresis, multiplex immunoassay and mass spectrometry profiling studies.
Size dependence of magnetorheological properties of cobalt ferrite ferrofluid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Radhika, B.; Sahoo, Rasmita; Srinath, S., E-mail: srinath@uohyd.ac.in
2015-06-24
Cobalt Ferrite nanoparticles were synthesized using co-precipitation method at reaction temperatures of 40°C and 80°C. X-Ray diffraction studies confirm cubic phase formation. The average crystallite sizes were found to be ∼30nm and ∼48nm for 40°C sample and 80°C sample respectively. Magnetic properties measured using vibrating sample magnetometer show higher coercivety and magnetization for sample prepared at 80°C. Magnetorheological properties of CoFe2O4 ferrofluids were measured and studied.
Depth-Resolved Cathodoluminescence Study of Annealed Silicon Implanted Gallium Arsenide.
1982-12-01
samples were Cr doped semi-insulat- ing GaAs crystals grown using the horizontal Bridgman method. Nine samples were prepared for this study, four were...function of depth. Cathodoluminescence was the excitation method. The crystals studied were grown using the horizontal Bridgman method. Four samples were...achieved by taking spectral data and successively chemically etching the surface of the crystal in 250 R steps. No new peaks were observed in the
2017-10-01
in the baseline samples of the Scleroderma Lung Study II (SLS II). We are currently analyzing whether these serum proteins have predictive...In this project, we use the valuable samples collected in the Scleroderma Lung Study II (SLSII) clinical trial and the observational cohort, GENISOS...determine key serum protein levels and transcript signatures in whole blood and skin samples collected in the SLSII study . The identified candidate
Rare-Earth Oxide (Yb2O3) Selective Emitter Fabrication and Evaluation
NASA Technical Reports Server (NTRS)
Jennette, Bryan; Gregory, Don A.; Herren, Kenneth; Tucker, Dennis; Smith, W. Scott (Technical Monitor)
2001-01-01
This investigation involved the fabrication and evaluation of rare-earth oxide selective emitters. The first goal of this study was to successfully fabricate the selective emitter samples using paper and ceramic materials processing techniques. The resulting microstructure was also analyzed using a Scanning Electron Microscope. All selective emitter samples fabricated for this study were made with ytterbium oxide (Yb2O3). The second goal of this study involved the measurement of the spectral emission and the radiated power of all the selective emitter samples. The final goal of this study involved the direct comparison of the radiated power emitted by the selective emitter samples to that of a standard blackbody at the same temperature and within the same wavelength range.
O'Brien, Kathryn; Stanton, Naomi; Edwards, Adrian; Hood, Kerenza; Butler, Christopher C
2011-03-01
Due to the non-specific nature of symptoms of UTI in children and low levels of urine sampling, the prevalence of UTI amongst acutely ill children in primary care is unknown. To undertake an exploratory study of acutely ill children consulting in primary care, determine the feasibility of obtaining urine samples, and describe presenting symptoms and signs, and the proportion with UTI. Exploratory, observational study. Four general practices in South Wales. A total of 99 sequential attendees with acute illness aged less than five years. UTI defined by >10(5) organisms/ml on laboratory culture of urine. Urine samples were obtained in 75 (76%) children. Three (4%) met microbiological criteria for UTI. GPs indicated they would not normally have obtained urine samples in any of these three children. However, all had received antibiotics for suspected alternative infections. Urine sample collection is feasible from the majority of acutely ill children in primary care, including infants. Some cases of UTI may be missed if children thought to have an alternative site of infection are excluded from urine sampling. A larger study is needed to more accurately determine the prevalence of UTI in children consulting with acute illness in primary care, and to explore which symptoms and signs might help clinicians effectively target urine sampling.
Genetic Association of MPPED2 and ACTN2 with Dental Caries
Stanley, B.O.C.; Feingold, E.; Cooper, M.; Vanyukov, M.M.; Maher, B.S.; Slayton, R.L.; Willing, M.C.; Reis, S.E.; McNeil, D.W.; Crout, R.J.; Weyant, R.J.; Levy, S.M.; Vieira, A.R.; Marazita, M.L.; Shaffer, J.R.
2014-01-01
The first genome-wide association study of dental caries focused on primary teeth in children aged 3 to 12 yr and nominated several novel genes: ACTN2, EDARADD, EPHA7, LPO, MPPED2, MTR, and ZMPSTE24. Here we interrogated 156 single-nucleotide polymorphisms (SNPs) within these candidate genes for evidence of association with dental caries experience in 13 race- and age-stratified samples from 6 independent studies (n = 3600). Analysis was performed separately for each sample, and results were combined across samples via meta-analysis. MPPED2 was significantly associated with caries via meta-analysis across the 5 childhood samples, with 4 SNPs showing significant associations after gene-wise adjustment for multiple comparisons (p < .0026). These results corroborate the previous genome-wide association study, although the functional role of MPPED2 in caries etiology remains unknown. ACTN2 also showed significant association via meta-analysis across childhood samples (p = .0014). Moreover, in adults, genetic association was observed for ACTN2 SNPs in individual samples (p < .0025), but no single SNP was significant via meta-analysis across all 8 adult samples. Given its compelling biological role in organizing ameloblasts during amelogenesis, this study strengthens the hypothesis that ACTN2 influences caries risk. Results for the other candidate genes neither proved nor precluded their associations with dental caries. PMID:24810274
Comparison of ELISA and Microscopy for detection of Cryptosporidium in stool
Sharma, Madhu; Chaudhary, Uma; Yadav, Aparna
2014-01-01
Background: Cryptosporidiosis, a diarrheal disease caused by the protozoan parasite Cryptosporidium spp. has become recognized as one of the most common causes of water borne diseases in humans. Aims and Objectives: To compare the sensitivity of ELISA and Microscopy for detection of Cryptosporidium in stool samples Materials and Methods: The study was conducted in the Department of Microbiology of PT. B.D. Sharma PGIMS Rohtak, between January 2011 to june 2011 on 50 stool samples, which were processed for detection of cryptosporidial antigen by ELISA and detection of cysts by microscopy (Modified Ziehl and Nelsen staining). Study and Design: This was a prospective study conducted in the Department of Microbiology in PT. BD Sharma, PGIMS, Rohtak, India. Result: Out of total, 50 stool samples eighteen (36%) samples were found positive for Cryptosporidium cysts by microscopy in comparison to 3(6%) stool samples which were found positive for cryptosporidial antigen by ELISA. Samples found positive with ELISA were also positive with microscopy. Sensitivity, specificity, positive predictive value and negative predictive value for ELISA was 16.7%, 100%, 100% and 68% respectively. Conclusion: The study concludes that stool microscopic Modified acid fast staining is more sensitive method than ELISA for detection of Cryptosporidium in stool samples but the specificity of ELISA was more than microscopy. PMID:25584216
Prediction of reinforced concrete strength by ultrasonic velocities
NASA Astrophysics Data System (ADS)
Sabbağ, Nevbahar; Uyanık, Osman
2017-06-01
This study was aimed to determine the strength of the reinforced concrete and to reveal the reinforcement effect on the concrete strength by Ultrasonic P and S wave velocities. Studies were conducted with prepared 9 different concrete designs of showing low, medium and high strength features. 4 kinds of cubic samples which unreinforced and including 10, 14 or 20 mm diameter reinforcement were prepared for these designs. Studies were carried out on total 324 samples including 9 samples for each design of these 4 kinds. The prepared samples of these designs were subjected to water curing. On some days of the 90-day period, P and S wave measurements were repeated to reveal the changes in seismic velocities of samples depending on whether reinforced or unreinforced of samples and diameter of reinforcement. Besides, comparisons were done by performing uniaxial compressive strength test with crushing of 3 samples on 7th, 28th and 90th days. As a result of studies and evaluations, it was seen that values of seismic velocities and uniaxial compressive strength increased depending on reinforcement and diameter of reinforcement in low strength concretes. However, while the seismic velocities were not markedly affected from reinforcement or reinforcement diameter in high strength concrete, uniaxial compressive strength values were negatively affected.
Does Nosema ceranae Wipe Out Nosema apis in Turkey?
Ivgin Tunca, Rahşan; Oskay, Devrim; Gosterit, Ayhan; Tekin, Olgay Kaan
2016-01-01
The aim of this study was to determine the prevalence of the Nosema ceranae and Nosema apis among apiaries using both spore counts and multiplex PCR and the replacement of N. apis by N. ceranae in some regions of Turkey. A hundred honey bee samples were collected from 99 apiaries in 11 different locations in 2011-2012 in Turkey. Nosema infection degree from collected samples was determined using light microscope and molecular detection of Nosema spp. ( N. ceranae and N. apis ) was performed using specific primers by multiplex PCR. N. ceranae was only found spores in sampling areas using molecular diagnosis. N. apis was not detected in whole sampling areas using both techniques. There are no Nosema spores detected in Konya one location using two techniques. The nucleotide sequences from amplification products of the Nosema infested honeybee samples were (98%) identical with the sequence of N. ceranae for many countries deposited in the GenBank database in this study. The present study illustrated that N. ceranae is the only spores for sampled areas in 2011-2012. The study could also indicate that N. ceranae has been replaced instead of N . apis in Turkey. In addition, the prevalence of N. ceranae and two microsporodia spores effects on honey bee colonies in Turkey were needed to determine with intensive sampling, periodically.
NASA Astrophysics Data System (ADS)
Lotfy, H.; Heleika, M. Abu; Mostafa, R.; Wahbah, D.
2017-12-01
The paleomagnetic study was carried out on three sections of the Late Ypresian "Minia" formation limestone, in order to shed light on the paleolatitude of northeast Africa upon the end of the Early Eocene. The initial study on the anisotropy of magnetic susceptibility [AMS] helped in confining the paleomagnetic sampling to the virtually isotropic limestone beds. The subsequent stepwise thermal demagnetization of the three-axis isothermal remanence acquired in one sample of each sampled site, revealed the limited contribution of goethite and hematite with the main remanence carrier magnetite in most samples.
Stark, James R.; Fallon, J.D.; Fong, A.L.; Goldstein, R.M.; Hanson, P.E.; Kroening, S.E.; Lee, K.E.
1999-01-01
This report describes the design, site-selection, and implementation of the study. Methods used to collect, process, and analyze samples; characterize sites; and assess habitat are described. A comprehensive list of sample sites is provided. Sample analyses for water-quality studies included chlorophyll a, major inorganic constituents, nutrients, trace elements, tritium, radon, environmental isotopes, organic carbon, pesticides, volatile organic compounds, and other synthetic and naturallyoccurring organic compounds. Aquatic-biological samples included fish, benthic macroinvertebrates, and algal enumeration and identification, as well as synthetic-organic compounds and trace elements in fish tissue.
Ledesma-Escobar, Carlos A.; Priego-Capote, Feliciano; Luque de Castro, María D.
2016-01-01
Background Flavonoids have shown to exert multiple beneficial effects on human health, being also appreciated by both food and pharmaceutical industries. Citrus fruits are a key source of flavonoids, thus promoting studies to obtain them. Characteristics of these studies are the discrepancies among sample pretreatments and among extraction methods, and also the scant number of comparative studies developed so far. Objective Evaluate the effect of both the sample pretreatment and the extraction method on the profile of flavonoids isolated from lemon. Results Extracts from fresh, lyophilized and air-dried samples obtained by shaking extraction (SE), ultrasound-assisted extraction (USAE), microwave-assisted extraction (MAE) and superheated liquid extraction (SHLE) were analyzed by LC–QTOF MS/MS, and 32 flavonoids were tentatively identified using MS/MS information. ANOVA applied to the data from fresh and dehydrated samples and from extraction by the different methods revealed that 26 and 32 flavonoids, respectively, were significant (p≤0.01). The pairwise comparison (Tukey HSD; p≤0.01) showed that lyophilized samples are more different from fresh samples than from air-dried samples; also, principal component analysis (PCA) showed a clear discrimination among sample pretreatment strategies and suggested that such differences are mainly created by the abundance of major flavonoids. On the other hand, pairwise comparison of extraction methods revealed that USAE and MAE provided quite similar extracts, being SHLE extracts different from the other two. In this case, PCA showed a clear discrimination among extraction methods, and their position in the scores plot suggests a lower abundance of flavonoids in the extracts from SHLE. In the two PCA the loadings plots revealed a trend to forming groups according to flavonoid aglycones. Conclusions The present study shows clear discrimination caused by both sample pretreatments and extraction methods. Under the studied conditions, liophilization provides extracts with higher amounts of flavonoids, and USAE is the best method for isolation of these compounds, followed by MAE and SE. On the contrary, the SHLE method was the less favorable to extract flavonoids from citrus owing to degradation. PMID:26807979
Qualitative evaluation of maternal milk and commercial infant formulas via LIBS.
Abdel-Salam, Z; Al Sharnoubi, J; Harith, M A
2013-10-15
This study focuses on the use of laser-induced breakdown spectroscopy (LIBS) for the evaluation of the nutrients in maternal milk and some commercially available infant formulas. The results of such evaluation are vital for adequate and healthy feeding for babies during lactation period. Laser-induced breakdown spectroscopy offers special advantages in comparison to the other conventional analytical techniques. Specifically, LIBS is a straightforward technique that can be used in situ to provide qualitative analytical information in few minutes for the samples under investigation without preparation processes. The samples studied in the current work were maternal milk samples collected during the first 3 months of lactation (not colostrum milk) and samples from six different types of commercially available infant formulas. The samples' elemental composition has been compared with respect to the relative abundance of the elements of nutrition importance, namely Mg, Ca, Na, and Fe using their spectral emission lines in the relevant LIBS spectra. In addition, CN and C2 molecular emission bands in the same spectra have been studied as indicators of proteins content in the samples. The obtained analytical results demonstrate the higher elemental contents of the maternal milk compared with the commercial formulas samples. Similar results have been obtained as for the proteins content. It has been also shown that calcium and proteins have similar relative concentration trends in the studied samples. This work demonstrates the feasibility of adopting LIBS as a fast, safe, less costly technique evaluating qualitatively the nutrients content of both maternal and commercial milk samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2006-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's LabMaster data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality-control samples analyzed from July 1999 through June 2001. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, calcium, chloride and nitrate (ion chromatography and colormetric method) and sulfate. The total aluminum and dissolved organic carbon procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits. The calcium and specific conductance procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The magnesium procedure was biased for the high-concentration and low concentration samples, but was within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 14 of 15 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 17 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except ammonium (81 percent of samples met objectives), chloride (75 percent of samples met objectives), and sodium (86 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality over the time period, with most ratings for each sample in the good to excellent range. The P-sample (low-ionic-strength constituents) analysis had one satisfactory rating for the specific conductance procedure in one study. The T-sample (trace constituents) analysis had one satisfactory rating for the aluminum procedure in one study and one unsatisfactory rating for the sodium procedure in another. The remainder of the samples had good or excellent ratings for each study. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 89 percent of the samples met data-quality objectives for 10 of the 14 analytes; the exceptions were ammonium, total aluminum, dissolved organic carbon, and sodium. Results indicate a positive bias for the ammonium procedure in all studies. Data-quality objectives were not met in 50 percent of samples analyzed for total aluminum, 38 percent of samples analyzed for dissolved organic carbon, and 27 percent of samples analyzed for sodium. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 91 percent of the samples analyzed for calcium, chloride, fluoride, magnesium, pH, potassium, and sulfate. Data-quality objectives were met by 75 percent of the samples analyzed for sodium and 58 percent of the samples analyzed for specific conductance.
SAMPLING ARTIFACT ESTIMATES FOR ALKANES, HOPANES, AND ALIPHATIC CARBOXYLIC ACIDS
Sampling artifacts for molecular markers from organic speciation of particulate matter were investigated by analyzing forty-one samples collected in Philadelphia as a part of the Northeast Oxidant and Particulate Study (NEOPS). Samples were collected using a high volume sampler ...
Surriabre, Pedro; Allende, Gustavo; Prado, Marcela; Cáceres, Leyddy; Bellot, Diego; Torrico, Andrea; Ustariz, Karina; Rojas, Shirley; Barriga, Jaime; Calle, Pamela; Villarroel, Ligia; Yañez, Rosse Mary; Baay, Marc; Rodriguez, Patricia; Fontaine, Véronique
2017-12-22
Cervical cancer incidence and mortality rates in Bolivia are among the highest in Latin America. This investigation aims to evaluate the possibility of using simple devices, e.g. a cotton swab and a glass slide, for self-sampling in order to detect human papillomavirus (HPV) DNA by PCR in cervico-vaginal cells. In the first phase of our study we evaluated the use of a glass slide as a transport medium for cervical cells. A physician took paired-cervical samples from 235 women. One sample was transported in Easyfix® solution and the other sample was smeared over a glass slide. Both were further analyzed and compared for human DNA recovery and HPV detection. A kappa value was determined to evaluate the agreement between the HPV DNA detection rates. In the second phase of the study, 222 women from the urban, peri-urban and rural regions of Cochabamba were requested to perform self-sampling using the following devices: a cotton swab combined with a glass slide, and a vaginal tampon. Women gave their opinion about the self-sampling technique. Finally, the agreement for high risk-HPV detection between self- and physician-collected samples was performed in 201 samples in order to evaluate the self-sampling technique. Firstly, the comparison between Easyfix® solution and the glass slide to transport clinical samples gave a good agreement for HPV DNA detection (κ = 0.71, 95% CI 0.60-0.81). Secondly, self-sampling, especially with cotton swab combined with glass slide, would generally be preferred over clinician sampling for a screening program based on HPV detection. Finally, we showed a good agreement between self- and physician collected samples for high risk-HPV detection (κ = 0.71, 95% CI 0.55-0.88). Simple devices such as a cotton swab and a glass slide can be used to perform self-sampling and HPV DNA detection. Furthermore, most Bolivian women preferred self-sampling over clinician-sampling for cervical cancer screening.
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--QA ANALYTICAL RESULTS FOR METALS IN BLANK SAMPLES
The Metals in Blank Samples data set contains the analytical results of measurements of up to 27 metals in 52 blank samples. Measurements were made in blank samples of dust, indoor air, food, water, and dermal wipe residue. Blank samples were used to assess the potential for sa...
Evaluation of storage and filtration protocols for alpine/subalpine lake water quality samples
John L. Korfmacher; Robert C. Musselman
2007-01-01
Many government agencies and other organizations sample natural alpine and subalpine surface waters using varying protocols for sample storage and filtration. Simplification of protocols would be beneficial if it could be shown that sample quality is unaffected. In this study, samples collected from low ionic strength waters in alpine and subalpine lake inlets...
NASA Astrophysics Data System (ADS)
Konrad, C.; Walther, W.; Reimann, T.; Rogge, A.; Stengel, P.; Well, R.
2008-03-01
Comparison of hydraulic and chemical properties of sediments from flush- and core drillings in the area of Peine (Germany). Because of financial constraints, investigations of nitrate metabolism are often based on disturbed borehole samples. It is arguable, however, whether disturbed samples are suitable for these types of investigations. Disadvantages of disturbed samples in comparison to undisturbed core samples are well known and include possible contamination of the sample by mud additives, destruction of the sediment formation and the insecurity concerning the correct depth allocation. In this study, boreholes were drilled at three locations to a maximum depth of 50 m. The extracted samples, as intact sediment cores and drill cuttings, were studied with regard to chemical and hydraulic parameters of the aquifer sediments. The results show: 1. hydraulic parameters are not affected by clay-based mud; 2. disturbed samples contain less fine grain material relative to the core samples, and the hydraulic conductivity can only be estimated from catch samples; 3. catch samples contain fewer reducing agents (sulphides, organic carbon) than core samples in hydraulically passive zones (defined as K < 10 6 m · s 1); 4. the results of analyses of disturbed and undisturbed core samples are in good agreement for hydraulically active zones (K ≥ 10 6 m · s 1).
Approaches to Recruiting ‘Hard-To-Reach’ Populations into Research: A Review of the Literature
Shaghaghi, Abdolreza; Bhopal, Raj S; Sheikh, Aziz
2011-01-01
Background: ‘Hard-to-reach’ is a term used to describe those sub-groups of the population that may be difficult to reach or involve in research or public health programmes. Application of a single term to call these sub-sections of populations implies a homogeneity within distinct groups, which does not necessarily exist. Different sampling techniques were introduced so far to recruit hard-to-reach populations. In this article, we have reviewed a range of approaches that have been used to widen participation in studies. Methods: We performed a Pubmed and Google search for relevant English language articles using the keywords and phrases: (hard-to-reach AND population* OR sampl*), (hidden AND population* OR sample*) and (“hard to reach” AND population* OR sample*) and a consultation of the retrieved articles’ bibliographies to extract empirical evidence from publications that discussed or examined the use of sampling techniques to recruit hidden or hard-to-reach populations in health studies. Results: Reviewing the literature has identified a range of techniques to recruit hard-to-reach populations, including snowball sampling, respondent-driven sampling (RDS), indigenous field worker sampling (IFWS), facility-based sampling (FBS), targeted sampling (TS), time-location (space) sampling (TLS), conventional cluster sampling (CCS) and capture re-capture sampling (CR). Conclusion: The degree of compliance with a study by a certain ‘hard-to-reach’ group depends on the characteristics of that group, recruitment technique used and the subject of interest. Irrespective of potential advantages or limitations of the recruitment techniques reviewed, their successful use depends mainly upon our knowledge about specific characteristics of the target populations. Thus in line with attempts to expand the current boundaries of our knowledge about recruitment techniques in health studies and their applications in varying situations, we should also focus on possibly all contributing factors which may have an impact on participation rate within a defined population group. PMID:24688904
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2006-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance/quality-control data for the time period addressed in this report were stored in the laboratory's SAS data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality- control samples analyzed from July 1997 through June 1999. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration and (or) low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, ammonium, calcium, chloride, specific conductance, and sulfate. The data from the potassium and sodium analytical procedures are insufficient for evaluation. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 11 of 13 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. Blank analysis results for chloride showed that 22 percent of blanks did not meet data-quality objectives and results for dissolved organic carbon showed that 31 percent of the blanks did not meet data-quality objectives. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 14 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except total aluminum (70 percent of samples met objectives) and potassium (83 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality for most constituents over the time period. The P-sample (low-ionic-strength constituents) analysis had good ratings in two of these studies and a satisfactory rating in the third. The results of the T-sample (trace constituents) analysis indicated high data quality with good ratings in all three studies. The N-sample (nutrient constituents) studies had one each of excellent, good, and satisfactory ratings. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 80 percent of the samples met data-quality objectives for 9 of the 13 analytes; the exceptions were dissolved organic carbon, ammonium, chloride, and specific conductance. Data-quality objectives were not met for dissolved organic carbon in two NWRI studies, but all of the samples were within control limits for the last study. Data-quality objectives were not met in 41 percent of samples analyzed for ammonium, 25 percent of samples analyzed for chloride, and 30 percent of samples analyzed for specific conductance. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 84 percent of the samples analyzed for calcium, chloride, magnesium, pH, and potassium. Data-quality objectives were met by 73 percent of those analyzed for sulfate. The data-quality objective was not met for sodium. The data are insufficient for evaluation of the specific conductance results.
Human Papilloma Virus (HPV) self-sampling: do women accept it?
Abdullah, Nik Nairan; Daud, Suzanna; Wang, Seok Mui; Mahmud, Zamalia; Mohd Kornain, Noor Kaslina; Al-Kubaisy, Waqar
2018-04-01
This study aims to determine the acceptability of Human Papilloma Virus (HPV) self-sampling and the factors associated with willingness to buy HPV self-sampling kit in the future. A total of 164 women aged 28-60 years old from Obstetrics & Gynaecology clinics at a teaching hospital performed HPV self-sampling using the Digene HC2 DNA collection kit. After samples were taken, the participants were given self-administered questionnaires. The majority of the participants were Malay (93.9%), had attained tertiary education (65.2%) and were employed (70.1%). The acceptability was good. More than half of the participants felt that self-sampling was easy. Only 1.2% felt that the procedure was difficult to perform. Most reported no pain at all during the procedure (66.9%). The commonest concern was getting a good sample (90.1%). A number of Pap smears were found to be significantly associated with the willingness to buy the HPV self-sampling kit. HPV self-sampling has the potential to be included in the cervical cancer screening programme. Impact Statement What is already known on this subject: HPV self-sampling is acceptable in some developed and developing countries. It is acceptable because it was easy to perform with very minimal pain or discomfort. Studies on the acceptance of self-screening are needed to plan a policy on self-sampling in the future. What the results of this study add: Our study adds new findings to the body of knowledge on self-sampling in the local population. We found that more women are willing to do the self-sampling at the clinic rather than at home. Although more than 90% expressed willingness to do self-sampling in the future, only 70% of them were willing to purchase the kit. Cost is a potential barrier to women who have the interest to perform the self-sampling. Given the global economic challenges, cost is inevitably an important predictor that we have to consider. What the implications are of these findings for clinical practice and/or further research: Future research should examine women from the rural areas and those who are resilient to Pap smear screening. In clinical practice, clinicians should acknowledge that cost is a potential barrier for women who are willing to do self-sampling. Self-sampling could be an option for women with no financial constraint to buy the kit. However, clinicians should counsel women so that they can make an informed choice in determining their screening method.
Pesticides in Wyoming Groundwater, 2008-10
Eddy-Miller, Cheryl A.; Bartos, Timothy T.; Taylor, Michelle L.
2013-01-01
Groundwater samples were collected from 296 wells during 1995-2006 as part of a baseline study of pesticides in Wyoming groundwater. In 2009, a previous report summarized the results of the baseline sampling and the statistical evaluation of the occurrence of pesticides in relation to selected natural and anthropogenic (human-related) characteristics. During 2008-10, the U.S. Geological Survey, in cooperation with the Wyoming Department of Agriculture, resampled a subset (52) of the 296 wells sampled during 1995-2006 baseline study in order to compare detected compounds and respective concentrations between the two sampling periods and to evaluate the detections of new compounds. The 52 wells were distributed similarly to sites used in the 1995-2006 baseline study with respect to geographic area and land use within the geographic area of interest. Because of the use of different types of reporting levels and variability in reporting-level values during both the 1995-2006 baseline study and the 2008-10 resampling study, analytical results received from the laboratory were recensored. Two levels of recensoring were used to compare pesticides—a compound-specific assessment level (CSAL) that differed by compound and a common assessment level (CAL) of 0.07 microgram per liter. The recensoring techniques and values used for both studies, with the exception of the pesticide 2,4-D methyl ester, were the same. Twenty-eight different pesticides were detected in samples from the 52 wells during the 2008-10 resampling study. Pesticide concentrations were compared with several U.S. Environmental Protection Agency drinking-water standards or health advisories for finished (treated) water established under the Safe Drinking Water Act. All detected pesticides were measured at concentrations smaller than U.S. Environmental Protection Agency drinking-water standards or health advisories where applicable (many pesticides did not have standards or advisories). One or more pesticides were detected at concentrations greater than the CAL in water from 16 of 52 wells sampled (about 31 percent) during the resampling study. Detected pesticides were classified into one of six types: herbicides, herbicide degradates, insecticides, insecticide degradates, fungicides, or fungicide degradates. At least 95 percent of detected pesticides were classified as herbicides or herbicide degradates. The number of different pesticides detected in samples from the 52 wells was similar between the 1995-2006 baseline study (30 different pesticides) and 2008-2010 resampling study (28 different pesticides). Thirteen pesticides were detected during both studies. The change in the number of pesticides detected (without regard to which pesticide was detected) in groundwater samples from each of the 52 wells was evaluated and the number of pesticides detected in groundwater did not change for most of the wells (32). Of those that did have a difference between the two studies, 17 wells had more pesticide detections in groundwater during the 1995-2006 baseline study, whereas only 3 wells had more detections during the 2008-2010 resampling study. The difference in pesticide concentrations in groundwater samples from each of the 52 wells was determined. Few changes in concentration between the 1995-2006 baseline study and the 2008-2010 resampling study were seen for most detected pesticides. Seven pesticides had a greater concentration detected in the groundwater from the same well during the baseline sampling compared to the resampling study. Concentrations of prometon, which was detected in 17 wells, were greater in the baseline study sample compared to the resampling study sample from the same well 100 percent of the time. The change in the number of pesticides detected (without regard to which pesticide was detected) in groundwater samples from each of the 52 wells with respect to land use and geographic area was calculated. All wells with land use classified as agricultural had the same or a smaller number of pesticides detected in the resampling study compared to the baseline study. All wells in the Bighorn Basin geographic area also had the same or a smaller number of pesticides detected in the resampling study compared to the baseline study.
ERIC Educational Resources Information Center
Wray, Alisha M.; Mahoney, Amanda; Weetjens, Bart J.; Cox, Christophe; Jubitana, Maureen; Kazwala, Rudovic; Mfinanga, Godfrey S.; Durgin, Amy; Poling, Alan
2013-01-01
Previous studies have shown that pouched rats can detect the presence of "Mycobacterium tuberculosis," which causes tuberculosis, in human sputum samples obtained from clinical facilities. Although pouched rats evaluate sputum samples quickly, preparing the samples is relatively slow. The present study evaluated whether the rats can detect…
Varieties of Stimulus Control in Matching-to-Sample: A Kernel Analysis
ERIC Educational Resources Information Center
Fields, Lanny; Garruto, Michelle; Watanabe, Mari
2010-01-01
Conditional discrimination or matching-to-sample procedures have been used to study a wide range of complex psychological phenomena with infrahuman and human subjects. In most studies, the percentage of trials in which a subject selects the comparison stimulus that is related to the sample stimulus is used to index the control exerted by the…
Workforce Readiness: A Study of University Students' Fluency with Information Technology
ERIC Educational Resources Information Center
Kaminski, Karen; Switzer, Jamie; Gloeckner, Gene
2009-01-01
This study with data collected from a large sample of freshmen in 2001 and a random stratified sample of seniors in 2005 examined students perceived FITness (fluency with Information Technology). In the fall of 2001 freshmen at a medium sized research-one institution completed a survey and in spring 2005 a random sample of graduating seniors…
ERIC Educational Resources Information Center
Bakar, Ab Rahim; Mohamed, Shamsiah; Hamzah, Ramlah
2013-01-01
This study was performed to identify the employability skills of technical students from the Industrial Training Institutes (ITI) and Indigenous People's Trust Council (MARA) Skills Training Institutes (IKM) in Malaysia. The study sample consisted of 850 final year trainees of IKM and ITI. The sample was chosen by a random sampling procedure from…
ERIC Educational Resources Information Center
Chin, Eu Gene; Ebesutani, Chad; Young, John
2013-01-01
The tripartite model of anxiety and depression has received strong support among child and adolescent populations. Clinical samples of children and adolescents in these studies, however, have usually been referred for treatment of anxiety and depression. This study investigated the fit of the tripartite model with a complicated sample of…
The purpose of this SOP is to describe the procedures undertaken to calculate sampling weights. The sampling weights are needed to obtain weighted statistics of the study data. This SOP uses data that have been properly coded and certified with appropriate QA/QC procedures by th...
Scientific Temper among Academically High and Low Achieving Adolescent Girls
ERIC Educational Resources Information Center
Kour, Sunmeet
2015-01-01
The present study was undertaken to compare the scientific temper of high and low achieving adolescent girl students. Random sampling technique was used to draw the sample from various high schools of District Srinagar. The sample for the present study consisted of 120 school going adolescent girls (60 high and 60 low achievers). Data was…
The purpose of this SOP is to establish a uniform procedure for the collection of yard composite soil samples in the field. This procedure was followed to ensure consistent and reliable collection of outdoor soil samples during the Arizona NHEXAS project and the "Border" study. ...
The Arizona Border Study used a system that tracks what occurs to a sample and provides the status of that sample at any given time. In essence, the tracking system provides an electronic chain of custody record for each sample as it moves through the project. This is achieved ...
The Influence of Principals Self Personality Values towards Their Work Culture
ERIC Educational Resources Information Center
Asri, Muhammad; Tahir, Lokman Bin Mohd.
2014-01-01
This study aimed to identify the influence of principals' self personality values toward teachers' work culture in high schools. The sample consisted of 34 principals from SMAN, SMKN and MAN in the City of Makassar, South Sulawesi Indonesia. The sample of this study is population sample. The instrument used was a questionnaire. Data were analyzed…
The Sampling Design of the China Family Panel Studies (CFPS)
Xie, Yu; Lu, Ping
2018-01-01
The China Family Panel Studies (CFPS) is an on-going, nearly nationwide, comprehensive, longitudinal social survey that is intended to serve research needs on a large variety of social phenomena in contemporary China. In this paper, we describe the sampling design of the CFPS sample for its 2010 baseline survey and methods for constructing weights to adjust for sampling design and survey nonresponses. Specifically, the CFPS used a multi-stage probability strategy to reduce operation costs and implicit stratification to increase efficiency. Respondents were oversampled in five provinces or administrative equivalents for regional comparisons. We provide operation details for both sampling and weights construction. PMID:29854418
Study of activation of metal samples from LDEF-1 and Spacelab-2
NASA Technical Reports Server (NTRS)
Laird, C. E.
1991-01-01
The activation of metal samples and other material orbited onboard the Long Duration Exposure Facility (LDEF) and Spacelab-2 were studied. Measurements of the radioactivities of spacecraft materials were made, and corrections for self-absorption and efficiency were calculated. Activation cross sections for specific metal samples were updated while cross sections for other materials were tabulated from the scientific literature. Activation cross sections for 200 MeV neutrons were experimentally determined. Linear absorption coefficients, half lives, branching ratios and other pertinent technical data needed for LDEF sample analyses were tabulated. The status of the sample counting at low background facilities at national laboratories is reported.
Statistical considerations for agroforestry studies
James A. Baldwin
1993-01-01
Statistical topics that related to agroforestry studies are discussed. These included study objectives, populations of interest, sampling schemes, sample sizes, estimation vs. hypothesis testing, and P-values. In addition, a relatively new and very much improved histogram display is described.
Automated DBS microsampling, microscale automation and microflow LC-MS for therapeutic protein PK.
Zhang, Qian; Tomazela, Daniela; Vasicek, Lisa A; Spellman, Daniel S; Beaumont, Maribel; Shyong, BaoJen; Kenny, Jacqueline; Fauty, Scott; Fillgrove, Kerry; Harrelson, Jane; Bateman, Kevin P
2016-04-01
Reduce animal usage for discovery-stage PK studies for biologics programs using microsampling-based approaches and microscale LC-MS. We report the development of an automated DBS-based serial microsampling approach for studying the PK of therapeutic proteins in mice. Automated sample preparation and microflow LC-MS were used to enable assay miniaturization and improve overall assay throughput. Serial sampling of mice was possible over the full 21-day study period with the first six time points over 24 h being collected using automated DBS sample collection. Overall, this approach demonstrated comparable data to a previous study using single mice per time point liquid samples while reducing animal and compound requirements by 14-fold. Reduction in animals and drug material is enabled by the use of automated serial DBS microsampling for mice studies in discovery-stage studies of protein therapeutics.
Willan, Andrew R; Eckermann, Simon
2012-10-01
Previous applications of value of information methods for determining optimal sample size in randomized clinical trials have assumed no between-study variation in mean incremental net benefit. By adopting a hierarchical model, we provide a solution for determining optimal sample size with this assumption relaxed. The solution is illustrated with two examples from the literature. Expected net gain increases with increasing between-study variation, reflecting the increased uncertainty in incremental net benefit and reduced extent to which data are borrowed from previous evidence. Hence, a trial can become optimal where current evidence is sufficient assuming no between-study variation. However, despite the expected net gain increasing, the optimal sample size in the illustrated examples is relatively insensitive to the amount of between-study variation. Further percentage losses in expected net gain were small even when choosing sample sizes that reflected widely different between-study variation. Copyright © 2011 John Wiley & Sons, Ltd.
Mevik, Kjersti; Griffin, Frances A; Hansen, Tonje E; Deilkås, Ellen T; Vonen, Barthold
2016-04-25
To investigate the impact of increasing sample of records reviewed bi-weekly with the Global Trigger Tool method to identify adverse events in hospitalised patients. Retrospective observational study. A Norwegian 524-bed general hospital trust. 1920 medical records selected from 1 January to 31 December 2010. Rate, type and severity of adverse events identified in two different samples sizes of records selected as 10 and 70 records, bi-weekly. In the large sample, 1.45 (95% CI 1.07 to 1.97) times more adverse events per 1000 patient days (39.3 adverse events/1000 patient days) were identified than in the small sample (27.2 adverse events/1000 patient days). Hospital-acquired infections were the most common category of adverse events in both the samples, and the distributions of the other categories of adverse events did not differ significantly between the samples. The distribution of severity level of adverse events did not differ between the samples. The findings suggest that while the distribution of categories and severity are not dependent on the sample size, the rate of adverse events is. Further studies are needed to conclude if the optimal sample size may need to be adjusted based on the hospital size in order to detect a more accurate rate of adverse events. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
An evaluation of soil sampling for 137Cs using various field-sampling volumes.
Nyhan, J W; White, G C; Schofield, T G; Trujillo, G
1983-05-01
The sediments from a liquid effluent receiving area at the Los Alamos National Laboratory and soils from an intensive study area in the fallout pathway of Trinity were sampled for 137Cs using 25-, 500-, 2500- and 12,500-cm3 field sampling volumes. A highly replicated sampling program was used to determine mean concentrations and inventories of 137Cs at each site, as well as estimates of spatial, aliquoting, and counting variance components of the radionuclide data. The sampling methods were also analyzed as a function of soil size fractions collected in each field sampling volume and of the total cost of the program for a given variation in the radionuclide survey results. Coefficients of variation (CV) of 137Cs inventory estimates ranged from 0.063 to 0.14 for Mortandad Canyon sediments, whereas CV values for Trinity soils were observed from 0.38 to 0.57. Spatial variance components of 137Cs concentration data were usually found to be larger than either the aliquoting or counting variance estimates and were inversely related to field sampling volume at the Trinity intensive site. Subsequent optimization studies of the sampling schemes demonstrated that each aliquot should be counted once, and that only 2-4 aliquots out of as many as 30 collected need be assayed for 137Cs. The optimization studies showed that as sample costs increased to 45 man-hours of labor per sample, the variance of the mean 137Cs concentration decreased dramatically, but decreased very little with additional labor.
Tvedt, Tor Henrik Anderson; Rye, Kristin Paulsen; Reikvam, Håkon; Brenner, Annette K; Bruserud, Øystein
2015-03-01
Cytokines, soluble adhesion molecules and metalloproteinases can be detected in human serum or plasma samples. Such systemic levels are widely used as biomarkers in epidemiological and clinical studies. We prepared serum samples and three types of plasma samples (EDTA, heparin, citric acid) from 20 healthy individuals. The levels of 31 cytokines, four soluble adhesion molecules and eight matrix metalloproteinases were analyzed by Luminex technology. Most mediators showed detectable levels in both plasma and serum. Several mediators that can be released by platelets showed increased serum levels, especially CCL5 and CD40L, but for the other mediators the serum levels did not correlate with peripheral blood platelet counts and for these last mediators serum and plasma levels often showed strong correlations. The use of bivalirudin for anticoagulation significantly increased and citric acid combined with platelet inhibitors (ticagrelor, acetylsalicylic acid plus prostaglandin E2) did not alter plasma levels of platelet-store mediators compared with citric acid alone. The impact of sample preparation differed between mediators; for many mediators strong correlations were seen between serum and plasma levels even when absolute levels differed. Soluble adhesion molecule levels showed only minor differences between samples. Unsupervised hierarchical clustering suggested that the effect of sampling/preparation was strongest for serum and heparin plasma samples. Careful standardization of sample preparation is usually necessary when analyzing systemic mediator levels, and differences caused by sample preparation should be considered as a possible explanation if studies show conflicting results. Copyright © 2015 Elsevier B.V. All rights reserved.
Flanders, W Dana; Kirkland, Kimberly H; Shelton, Brian G
2014-10-01
Outbreaks of Legionnaires' disease require environmental testing of water samples from potentially implicated building water systems to identify the source of exposure. A previous study reports a large impact on Legionella sample results due to shipping and delays in sample processing. Specifically, this same study, without accounting for measurement error, reports more than half of shipped samples tested had Legionella levels that arbitrarily changed up or down by one or more logs, and the authors attribute this result to shipping time. Accordingly, we conducted a study to determine the effects of sample holding/shipping time on Legionella sample results while taking into account measurement error, which has previously not been addressed. We analyzed 159 samples, each split into 16 aliquots, of which one-half (8) were processed promptly after collection. The remaining half (8) were processed the following day to assess impact of holding/shipping time. A total of 2544 samples were analyzed including replicates. After accounting for inherent measurement error, we found that the effect of holding time on observed Legionella counts was small and should have no practical impact on interpretation of results. Holding samples increased the root mean squared error by only about 3-8%. Notably, for only one of 159 samples, did the average of the 8 replicate counts change by 1 log. Thus, our findings do not support the hypothesis of frequent, significant (≥= 1 log10 unit) Legionella colony count changes due to holding. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Risch, M.R.; Prestbo, E.M.; Hawkins, L.
2007-01-01
Ground-level concentrations of three atmospheric mercury species were measured using manual sampling and analysis to provide data for estimates of mercury dry deposition. Three monitoring stations were operated simultaneously during winter, spring, and summer 2004, adjacent to three mercury wet-deposition monitoring stations in northern, central, and southern Indiana. The monitoring locations differed in land-use setting and annual mercury-emissions level from nearby sources. A timer-controlled air-sampling system that contained a three-part sampling train was used to isolate reactive gaseous mercury, particulate-bound mercury, and elemental mercury. The sampling trains were exchanged every 6 days, and the mercury species were quantified in a laboratory. A quality-assurance study indicated the sampling trains could be held at least 120 h without a significant change in reactive gaseous or particulate-bound mercury concentrations. The manual sampling method was able to provide valid mercury concentrations in 90 to 95% of samples. Statistical differences in mercury concentrations were observed during the project. Concentrations of reactive gaseous and elemental mercury were higher in the daytime samples than in the nighttime samples. Concentrations of reactive gaseous mercury were higher in winter than in summer and were highest at the urban monitoring location. The results of this case study indicated manual sampling and analysis could be a reliable method for measurement of atmospheric mercury species and has the capability for supplying representative concentrations in an effective manner from a long-term deposition-monitoring network. ?? 2007 Springer Science+Business Media B.V.
Kral, Alex H; Malekinejad, Mohsen; Vaudrey, Jason; Martinez, Alexis N; Lorvick, Jennifer; McFarland, Willi; Raymond, H Fisher
2010-09-01
The objective of this article is to compare demographic characteristics, risk behaviors, and service utilization among injection drug users (IDUs) recruited from two separate studies in San Francisco in 2005, one which used targeted sampling (TS) and the other which used respondent-driven sampling (RDS). IDUs were recruited using TS (n = 651) and RDS (n = 534) and participated in quantitative interviews that included demographic characteristics, risk behaviors, and service utilization. Prevalence estimates and 95% confidence intervals (CIs) were calculated to assess whether there were differences in these variables by sampling method. There was overlap in 95% CIs for all demographic variables except African American race (TS: 45%, 53%; RDS: 29%, 44%). Maps showed that the proportion of IDUs distributed across zip codes were similar for the TS and RDS sample, with the exception of a single zip code that was more represented in the TS sample. This zip code includes an isolated, predominantly African American neighborhood where only the TS study had a field site. Risk behavior estimates were similar for both TS and RDS samples, although self-reported hepatitis C infection was lower in the RDS sample. In terms of service utilization, more IDUs in the RDS sample reported no recent use of drug treatment and syringe exchange program services. Our study suggests that perhaps a hybrid sampling plan is best suited for recruiting IDUs in San Francisco, whereby the more intensive ethnographic and secondary analysis components of TS would aid in the planning of seed placement and field locations for RDS.
Extrahuman Epidemiology of Acinetobacter baumannii in Lebanon
Rafei, Rayane; Hamze, Monzer; Pailhoriès, Hélène; Eveillard, Matthieu; Marsollier, Laurent; Joly-Guillou, Marie-Laure; Dabboussi, Fouad
2015-01-01
The presence of Acinetobacter baumannii outside hospitals is still a controversial issue. The objective of our study was to explore the extrahospital epidemiology of A. baumannii in Lebanon. From February 2012 to October 2013, a total of 73 water samples, 51 soil samples, 37 raw cow milk samples, 50 cow meat samples, 7 raw cheese samples, and 379 animal samples were analyzed by cultural methods for the presence of A. baumannii. Species identification was performed by rpoB gene sequencing. Antibiotic susceptibility was investigated, and the A. baumannii population was studied by two genotyping approaches: multilocus sequence typing (MLST) and blaOXA-51 sequence-based typing (SBT). A. baumannii was detected in 6.9% of water samples, 2.7% of milk samples, 8.0% of meat samples, 14.3% of cheese samples, and 7.7% of animal samples. All isolates showed a susceptible phenotype against most of the antibiotics tested and lacked carbapenemase-encoding genes, except one that harbored a blaOXA-143 gene. MLST analysis revealed the presence of 36 sequence types (STs), among which 24 were novel STs reported for the first time in this study. blaOXA-51 SBT showed the presence of 34 variants, among which 21 were novel and all were isolated from animal origins. Finally, 30 isolates had new partial rpoB sequences and were considered putative new Acinetobacter species. In conclusion, animals can be a potential reservoir for A. baumannii and the dissemination of new emerging carbapenemases. The roles of the novel animal clones identified in community-acquired infections should be investigated. PMID:25616788
Curtis, S; Gesler, W; Smith, G; Washburn, S
2000-04-01
This paper focuses on the question of sampling (or selection of cases) in qualitative research. Although the literature includes some very useful discussions of qualitative sampling strategies, the question of sampling often seems to receive less attention in methodological discussion than questions of how data is collected or is analysed. Decisions about sampling are likely to be important in many qualitative studies (although it may not be an issue in some research). There are varying accounts of the principles applicable to sampling or case selection. Those who espouse 'theoretical sampling', based on a 'grounded theory' approach, are in some ways opposed to those who promote forms of 'purposive sampling' suitable for research informed by an existing body of social theory. Diversity also results from the many different methods for drawing purposive samples which are applicable to qualitative research. We explore the value of a framework suggested by Miles and Huberman [Miles, M., Huberman,, A., 1994. Qualitative Data Analysis, Sage, London.], to evaluate the sampling strategies employed in three examples of research by the authors. Our examples comprise three studies which respectively involve selection of: 'healing places'; rural places which incorporated national anti-malarial policies; young male interviewees, identified as either chronically ill or disabled. The examples are used to show how in these three studies the (sometimes conflicting) requirements of the different criteria were resolved, as well as the potential and constraints placed on the research by the selection decisions which were made. We also consider how far the criteria Miles and Huberman suggest seem helpful for planning 'sample' selection in qualitative research.
Peng, Jun; Chen, Yi-Ting; Chen, Chien-Lun; Li, Liang
2014-07-01
Large-scale metabolomics study requires a quantitative method to generate metabolome data over an extended period with high technical reproducibility. We report a universal metabolome-standard (UMS) method, in conjunction with chemical isotope labeling liquid chromatography-mass spectrometry (LC-MS), to provide long-term analytical reproducibility and facilitate metabolome comparison among different data sets. In this method, UMS of a specific type of sample labeled by an isotope reagent is prepared a priori. The UMS is spiked into any individual samples labeled by another form of the isotope reagent in a metabolomics study. The resultant mixture is analyzed by LC-MS to provide relative quantification of the individual sample metabolome to UMS. UMS is independent of a study undertaking as well as the time of analysis and useful for profiling the same type of samples in multiple studies. In this work, the UMS method was developed and applied for a urine metabolomics study of bladder cancer. UMS of human urine was prepared by (13)C2-dansyl labeling of a pooled sample from 20 healthy individuals. This method was first used to profile the discovery samples to generate a list of putative biomarkers potentially useful for bladder cancer detection and then used to analyze the verification samples about one year later. Within the discovery sample set, three-month technical reproducibility was examined using a quality control sample and found a mean CV of 13.9% and median CV of 9.4% for all the quantified metabolites. Statistical analysis of the urine metabolome data showed a clear separation between the bladder cancer group and the control group from the discovery samples, which was confirmed by the verification samples. Receiver operating characteristic (ROC) test showed that the area under the curve (AUC) was 0.956 in the discovery data set and 0.935 in the verification data set. These results demonstrated the utility of the UMS method for long-term metabolomics and discovering potential metabolite biomarkers for diagnosis of bladder cancer.
Lenselink, Charlotte H.; de Bie, Roosmarie P.; van Hamont, Dennis; Bakkers, Judith M. J. E.; Quint, Wim G. V.; Massuger, Leon F. A. G.; Bekkers, Ruud L. M.; Melchers, Willem J. G.
2009-01-01
This study assesses human papillomavirus (HPV) detection and genotyping in self-sampled genital smears applied to an indicating FTA elute cartridge (FTA cartridge). The study group consisted of 96 women, divided into two sample sets. All samples were analyzed by the HPV SPF10-Line Blot 25. Set 1 consisted of 45 women attending the gynecologist; all obtained a self-sampled cervicovaginal smear, which was applied to an FTA cartridge. HPV results were compared to a cervical smear (liquid based) taken by a trained physician. Set 2 consisted of 51 women who obtained a self-sampled cervicovaginal smear at home, which was applied to an FTA cartridge and to a liquid-based medium. DNA was obtained from the FTA cartridges by simple elution as well as extraction. Of all self-obtained samples of set 1, 62.2% tested HPV positive. The overall agreement between self- and physician-obtained samples was 93.3%, in favor of the self-obtained samples. In sample set 2, 25.5% tested HPV positive. The overall agreement for high-risk HPV presence between the FTA cartridge and liquid-based medium and between DNA elution and extraction was 100%. This study shows that HPV detection and genotyping in self-obtained cervicovaginal samples applied to an FTA cartridge is highly reliable. It shows a high level of overall agreement with HPV detection and genotyping in physician-obtained cervical smears and liquid-based self-samples. DNA can be obtained by simple elution and is therefore easy, cheap, and fast. Furthermore, the FTA cartridge is a convenient medium for collection and safe transport at ambient temperatures. Therefore, this method may contribute to a new way of cervical cancer screening. PMID:19553570
Lenselink, Charlotte H; de Bie, Roosmarie P; van Hamont, Dennis; Bakkers, Judith M J E; Quint, Wim G V; Massuger, Leon F A G; Bekkers, Ruud L M; Melchers, Willem J G
2009-08-01
This study assesses human papillomavirus (HPV) detection and genotyping in self-sampled genital smears applied to an indicating FTA elute cartridge (FTA cartridge). The study group consisted of 96 women, divided into two sample sets. All samples were analyzed by the HPV SPF(10)-Line Blot 25. Set 1 consisted of 45 women attending the gynecologist; all obtained a self-sampled cervicovaginal smear, which was applied to an FTA cartridge. HPV results were compared to a cervical smear (liquid based) taken by a trained physician. Set 2 consisted of 51 women who obtained a self-sampled cervicovaginal smear at home, which was applied to an FTA cartridge and to a liquid-based medium. DNA was obtained from the FTA cartridges by simple elution as well as extraction. Of all self-obtained samples of set 1, 62.2% tested HPV positive. The overall agreement between self- and physician-obtained samples was 93.3%, in favor of the self-obtained samples. In sample set 2, 25.5% tested HPV positive. The overall agreement for high-risk HPV presence between the FTA cartridge and liquid-based medium and between DNA elution and extraction was 100%. This study shows that HPV detection and genotyping in self-obtained cervicovaginal samples applied to an FTA cartridge is highly reliable. It shows a high level of overall agreement with HPV detection and genotyping in physician-obtained cervical smears and liquid-based self-samples. DNA can be obtained by simple elution and is therefore easy, cheap, and fast. Furthermore, the FTA cartridge is a convenient medium for collection and safe transport at ambient temperatures. Therefore, this method may contribute to a new way of cervical cancer screening.
Optimal two-phase sampling design for comparing accuracies of two binary classification rules.
Xu, Huiping; Hui, Siu L; Grannis, Shaun
2014-02-10
In this paper, we consider the design for comparing the performance of two binary classification rules, for example, two record linkage algorithms or two screening tests. Statistical methods are well developed for comparing these accuracy measures when the gold standard is available for every unit in the sample, or in a two-phase study when the gold standard is ascertained only in the second phase in a subsample using a fixed sampling scheme. However, these methods do not attempt to optimize the sampling scheme to minimize the variance of the estimators of interest. In comparing the performance of two classification rules, the parameters of primary interest are the difference in sensitivities, specificities, and positive predictive values. We derived the analytic variance formulas for these parameter estimates and used them to obtain the optimal sampling design. The efficiency of the optimal sampling design is evaluated through an empirical investigation that compares the optimal sampling with simple random sampling and with proportional allocation. Results of the empirical study show that the optimal sampling design is similar for estimating the difference in sensitivities and in specificities, and both achieve a substantial amount of variance reduction with an over-sample of subjects with discordant results and under-sample of subjects with concordant results. A heuristic rule is recommended when there is no prior knowledge of individual sensitivities and specificities, or the prevalence of the true positive findings in the study population. The optimal sampling is applied to a real-world example in record linkage to evaluate the difference in classification accuracy of two matching algorithms. Copyright © 2013 John Wiley & Sons, Ltd.
Flores, Cindi G; Valcante, Gregory; Guter, Steve; Zaytoun, Annette; Wray, Emily; Bell, Lindsay; Jacob, Suma; Lewis, Mark H; Driscoll, Daniel J; Cook, Edwin H; Kim, Soo-Jeong
2011-12-01
Restricted and repetitive behavior (RRB) is a group of heterogeneous maladaptive behaviors. RRB is one of the key diagnostic features of autism spectrum disorders (ASDs) and also commonly observed in Prader-Willi syndrome (PWS). In this study, we assessed RRB using the Repetitive Behavior Scale-Revised (RBS-R) in two ASD samples (University of Illinois at Chicago [UIC] and University of Florida [UF]) and one PWS sample. We compared the RBS-R item endorsements across three ASD cohorts (UIC, UF and an ASD sample from Lam, The Repetitive Behavior Scale-Revised: independent validation and the effect of subject variables, PhD thesis, 2004), and a PWS sample. We also compared the mean RBS-R subscale/sum scores across the UIC, UF and PWS samples; across the combined ASD (UIC + UF), PWS-deletion and PWS-disomy groups; and across the combined ASD sample, PWS subgroup with a Social Communication Questionnaire (SCQ) score ≥15, and PWS subgroup with a SCQ score <15. Despite the highly heterogeneous nature, the three ASD samples (UIC, UF and Lam's) showed a similar pattern of the RBS-R endorsements, and the mean RBS-R scores were not different between the UIC and UF samples. However, higher RRB was noted in the ASD sample compared with the PWS sample, as well as in the PWS subgroup with a SCQ score ≥15 compared with the PWS subgroup with a SCQ score <15. Study limitations include a small sample size, a wide age range of our participants, and not controlling for potential covariates. A future replication study using a larger sample and further investigation into the genetic bases of overlapping ASD and RRB phenomenology are needed, given the higher RRB in the PWS subgroup with a SCQ score ≥15.
NASA Astrophysics Data System (ADS)
Sung, S.; Kim, H. G.; Lee, D. K.; Park, J. H.; Mo, Y.; Kil, S.; Park, C.
2016-12-01
The impact of climate change has been observed throughout the globe. The ecosystem experiences rapid changes such as vegetation shift, species extinction. In these context, Species Distribution Model (SDM) is one of the popular method to project impact of climate change on the ecosystem. SDM basically based on the niche of certain species with means to run SDM present point data is essential to find biological niche of species. To run SDM for plants, there are certain considerations on the characteristics of vegetation. Normally, to make vegetation data in large area, remote sensing techniques are used. In other words, the exact point of presence data has high uncertainties as we select presence data set from polygons and raster dataset. Thus, sampling methods for modeling vegetation presence data should be carefully selected. In this study, we used three different sampling methods for selection of presence data of vegetation: Random sampling, Stratified sampling and Site index based sampling. We used one of the R package BIOMOD2 to access uncertainty from modeling. At the same time, we included BioCLIM variables and other environmental variables as input data. As a result of this study, despite of differences among the 10 SDMs, the sampling methods showed differences in ROC values, random sampling methods showed the lowest ROC value while site index based sampling methods showed the highest ROC value. As a result of this study the uncertainties from presence data sampling methods and SDM can be quantified.
Bosgraaf, Remko P; Ketelaars, Pleun J W; Verhoef, Viola M J; Massuger, Leon F A G; Meijer, Chris J L M; Melchers, Willem J G; Bekkers, Ruud L M
2014-07-01
High attendance rates in cervical screening are essential for effective cancer prevention. Offering HPV self-sampling to non-responders increases participation rates. The objectives of this study were to determine why non-responders do not attend regular screening, and why they do or do not participate when offered a self-sampling device. A questionnaire study was conducted in the Netherlands from October 2011 to December 2012. A total of 35,477 non-responders were invited to participate in an HPV self-sampling study; 5347 women did opt out. Finally, 30,130 women received a questionnaire and self-sampling device. The analysis was based on 9484 returned questionnaires (31.5%) with a self-sample specimen, and 682 (2.3%) without. Among women who returned both, the main reason for non-attendance to cervical screening was that they forgot to schedule an appointment (3068; 32.3%). The most important reason to use the self-sampling device was the opportunity to take a sample in their own time-setting (4763; 50.2%). A total of 30.9% of the women who did not use the self-sampling device preferred after all to have a cervical smear taken instead. Organisational barriers are the main reason for non-attendance in regular cervical screening. Important reasons for non-responders to the regular screening to use a self-sampling device are convenience and self-control. Copyright © 2014 Elsevier Inc. All rights reserved.
Kaur, Gurpreet; Chandra, Mudit; Dwivedi, P N; Sharma, N S
2015-01-01
The aim of this study was to isolate Canine parvovirus (CPV) from suspected dogs on madin darby canine kidney (MDCK) cell line and its confirmation by polymerase chain reaction (PCR) and nested PCR (NPCR). Further, VP2 gene of the CPV isolates was amplified and sequenced to determine prevailing antigenic type. A total of 60 rectal swabs were collected from dogs showing signs of gastroenteritis, processed and subjected to isolation in MDCK cell line. The samples showing cytopathic effects (CPE) were confirmed by PCR and NPCR. These samples were subjected to PCR for amplification of VP2 gene of CPV, sequenced and analyzed to study the prevailing antigenic types of CPV. Out of the 60 samples subjected to isolation in MDCK cell line five samples showed CPE in the form of rounding of cells, clumping of cells and finally detachment of the cells. When these samples and the two commercially available vaccines were subjected to PCR for amplification of VP2 gene, a 1710 bp product was amplified. The sequence analysis revealed that the vaccines belonged to the CPV-2 type and the samples were of CPV-2b type. It can be concluded from the present study that out of a total of 60 samples 5 samples exhibited CPE as observed in MDCK cell line. Sequence analysis of the VP2 gene among the samples and vaccine strains revealed that samples belonged to CPV-2b type and vaccines belonging to CPV-2.
Chow, Jeffrey T Y; Turkstra, Timothy P; Yim, Edmund; Jones, Philip M
2018-06-01
Although every randomized clinical trial (RCT) needs participants, determining the ideal number of participants that balances limited resources and the ability to detect a real effect is difficult. Focussing on two-arm, parallel group, superiority RCTs published in six general anesthesiology journals, the objective of this study was to compare the quality of sample size calculations for RCTs published in 2010 vs 2016. Each RCT's full text was searched for the presence of a sample size calculation, and the assumptions made by the investigators were compared with the actual values observed in the results. Analyses were only performed for sample size calculations that were amenable to replication, defined as using a clearly identified outcome that was continuous or binary in a standard sample size calculation procedure. The percentage of RCTs reporting all sample size calculation assumptions increased from 51% in 2010 to 84% in 2016. The difference between the values observed in the study and the expected values used for the sample size calculation for most RCTs was usually > 10% of the expected value, with negligible improvement from 2010 to 2016. While the reporting of sample size calculations improved from 2010 to 2016, the expected values in these sample size calculations often assumed effect sizes larger than those actually observed in the study. Since overly optimistic assumptions may systematically lead to underpowered RCTs, improvements in how to calculate and report sample sizes in anesthesiology research are needed.
Al, Kait F; Bisanz, Jordan E; Gloor, Gregory B; Reid, Gregor; Burton, Jeremy P
2018-01-01
The increasing interest on the impact of the gut microbiota on health and disease has resulted in multiple human microbiome-related studies emerging. However, multiple sampling methods are being used, making cross-comparison of results difficult. To avoid additional clinic visits and increase patient recruitment to these studies, there is the potential to utilize at-home stool sampling. The aim of this pilot study was to compare simple self-sampling collection and storage methods. To simulate storage conditions, stool samples from three volunteers were freshly collected, placed on toilet tissue, and stored at four temperatures (-80, 7, 22 and 37°C), either dry or in the presence of a stabilization agent (RNAlater®) for 3 or 7days. Using 16S rRNA gene sequencing by Illumina, the effect of storage variations for each sample was compared to a reference community from fresh, unstored counterparts. Fastq files may be accessed in the NCBI Sequence Read Archive: Bioproject ID PRJNA418287. Microbial diversity and composition were not significantly altered by any storage method. Samples were always separable based on participant, regardless of storage method suggesting there was no need for sample preservation by a stabilization agent. In summary, if immediate sample processing is not feasible, short term storage of unpreserved stool samples on toilet paper offers a reliable way to assess the microbiota composition by 16S rRNA gene sequencing. Copyright © 2017 Elsevier B.V. All rights reserved.
Strength gradient enhances fatigue resistance of steels
NASA Astrophysics Data System (ADS)
Ma, Zhiwei; Liu, Jiabin; Wang, Gang; Wang, Hongtao; Wei, Yujie; Gao, Huajian
2016-02-01
Steels are heavily used in infrastructure and the transportation industry, and enhancing their fatigue resistance is a major challenge in materials engineering. In this study, by introducing a gradient microstructure into 304 austenitic steel, which is one of the most widely used types of stainless steel, we show that a strength gradient substantially enhances the fatigue life of the material. Pre-notched samples with negative strength gradients in front of the notch’s tip endure many more fatigue cycles than do samples with positive strength gradients during the crack initiation stage, and samples with either type of gradient perform better than do gradient-free samples with the same average yield strength. However, as a crack grows, samples with positive strength gradients exhibit better resistance to fatigue crack propagation than do samples with negative gradients or no gradient. This study demonstrates a simple and promising strategy for using gradient structures to enhance the fatigue resistance of materials and complements related studies of strength and ductility.
RBS/Channeling Studies of Swift Heavy Ion Irradiated GaN Layers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sathish, N.; Dhamodaran, S.; Pathak, A. P.
2009-03-10
Epitaxial GaN layers grown by MOCVD on c-plane sapphire substrates were irradiated with 150 MeV Ag ions at a fluence of 5x10{sup 12} ions/cm{sup 2}. Samples used in this study are 2 {mu}m thick GaN layers, with and without a thin AlN cap-layer. Energy dependent RBS/Channeling measurements have been carried out on both irradiated and unirradiated samples for defects characterization. Observed results are compared and correlated with previous HRXRD, AFM and optical studies. The {chi}{sub min} values for unirradiated samples show very high value and the calculated defect densities are of the order of 10{sup 10} cm{sup -2} as expectedmore » in these samples. Effects of irradiation on these samples are different as initial samples had different defect densities. Epitaxial reconstruction of GaN buffer layer has been attributed to the observed changes, which are generally grown to reduce the strain between GaN and Sapphire.« less
Monitoring IACP samples and construction of a centralized data base
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walsh, D.B.; Ray, D.B.; Simonson, J.
1991-01-01
The Integrated Air Cancer Project (IACP) is a multiyear US EPA research program established to develop and evaluate methods required to identify the principal airborne carcinogens, determine emission sources, and improve the estimate of comparative human cancer risk. The first major field study designed to examine a residential wood combustion airshed was conducted in Boise, Idaho during the 1986-1987 winter heating season. The second major field study conducted in Roanoke, Virgina during the 1988-1989 was to study residential oil heating and wood combustion. Motor vehicle emissions were considered a major combustion product contributor in both airsheds. This paper describes twomore » critical components of the project. The first component is the sample custody and tracking of the samples before analysis. The second component describes the data management of the sample field data (eg. sample site, time, date, flow rate) as well as the analytical data (eg. mutagenicity, particle concentrations) for the environmental samples.« less
Strength gradient enhances fatigue resistance of steels
Ma, Zhiwei; Liu, Jiabin; Wang, Gang; Wang, Hongtao; Wei, Yujie; Gao, Huajian
2016-01-01
Steels are heavily used in infrastructure and the transportation industry, and enhancing their fatigue resistance is a major challenge in materials engineering. In this study, by introducing a gradient microstructure into 304 austenitic steel, which is one of the most widely used types of stainless steel, we show that a strength gradient substantially enhances the fatigue life of the material. Pre-notched samples with negative strength gradients in front of the notch’s tip endure many more fatigue cycles than do samples with positive strength gradients during the crack initiation stage, and samples with either type of gradient perform better than do gradient-free samples with the same average yield strength. However, as a crack grows, samples with positive strength gradients exhibit better resistance to fatigue crack propagation than do samples with negative gradients or no gradient. This study demonstrates a simple and promising strategy for using gradient structures to enhance the fatigue resistance of materials and complements related studies of strength and ductility. PMID:26907708
Airborne endotoxin in woodworking (joinery) shops.
Harper, Martin; Andrew, Michael E
2006-01-01
Symptoms such as shortness of breath and cough have been noted in woodworking facilities even where wood dust itself is well-controlled. Suspicion has fallen on other possible contaminants in the workplace atmosphere, including bacterial endotoxin. A few studies have indicated potentially high endotoxin exposure with exposure to fresh wood in sawmills and in the production of fiberboard and chipboard, but fewer studies have been carried out on exposure to endotoxin in dry wood work, for example in joineries. A study of the endotoxin content of airborne wood dust samples from US woodworking facilities is presented, from the re-analysis of samples which previously had been taken to establish mass collection relationships between the IOM sampler, the closed-face 37 mm plastic cassette (CFC) sampler and the Button sampler. Endotoxin was strongly correlated with total dust, but the endotoxin content of a few fresh wood samples was found to be up to ten times higher per unit of wood dust than for dried-wood samples, and this difference was significant. No long-term time-weighted average sample exceeded the recommended limit value of 50 EU m(-3) (EU, endotoxin units)used in the Netherlands, although a number of the IOM samples came close (seven samples or 44% exceeded 20 EU m(-3)) and one short-term (48 minute) sample registered a high value of 73 EU m(-3). The geometric mean concentration from the IOM samples (11 EU m(-3)) is within the range of geometric means found from Australian joineries (3.7-60, combined: 24 EU m(-3)). In contrast, the corresponding values from the CFC (3.6 EU m(-3)), and the Button sampler (2.1 EU m(-3)) were much lower and no samples exceeded 20 EU m(-3). Endotoxin is likely only to be a significant problem in working with dried woods when associated with very high dust levels, where the wood dust itself is likely to be a cause for concern. The results from the few samples in this study where fresh wood was being worked were similar to results from other studies involving fresh woods. The agreement between these studies is encouraging given the difficulties of endotoxin analysis and the wide variation often expected between different laboratories.
Molds and mycotoxins in indoor environments--a survey in water-damaged buildings.
Bloom, Erica; Nyman, Eva; Must, Aime; Pehrson, Christina; Larsson, Lennart
2009-11-01
Mycotoxins are toxic, secondary metabolites frequently produced by molds in water-damaged indoor environments. We studied the prevalence of selected, potent mycotoxins and levels of fungal biomass in samples collected from water-damaged indoor environments in Sweden during a 1-year period. One hundred samples of building materials, 18 samples of settled dust, and 37 samples of cultured dust were analyzed for: (a) mycoflora by microscopy and culture; (b) fungal chemical marker ergosterol and hydrolysis products of macrocyclic trichothecenes and trichodermin (verrucarol and trichodermol) by gas chromatography-tandem mass spectrometry; and (c) sterigmatocystin, gliotoxin, aflatoxin B(1), and satratoxin G and H by high performance liquid chromatography-tandem mass spectrometry. Sixty-six percent of the analyzed building materials samples, 11% of the settled dust samples, and 51% of the cultured dust samples were positive for at least one of the studied mycotoxins. In addition, except in the case of gliotoxin, mycotoxin-positive building material samples contained 2-6 times more ergosterol than mycotoxin-negative samples. We show that (a) molds growing on a range of different materials indoors in water-damaged buildings generally produce mycotoxins, and (b) mycotoxin-containing particles in mold-contaminated environments may settle on surfaces above floor level. The mass spectrometry methods used in this study are valuable tools in further research to survey mycotoxin exposure and investigate potential links with health effects.
Online Recruitment: Feasibility, Cost, and Representativeness in a Study of Postpartum Women.
Leach, Liana S; Butterworth, Peter; Poyser, Carmel; Batterham, Philip J; Farrer, Louise M
2017-03-08
Online recruitment is feasible, low-cost, and can provide high-quality epidemiological data. However, little is known about the feasibility of recruiting postpartum women online, or sample representativeness. The current study investigates the feasibility of recruiting a population of postpartum women online for health research and examines sample representativeness. Two samples of postpartum women were compared: those recruited online as participants in a brief survey of new mothers (n=1083) and those recruited face-to-face as part of a nationally representative study (n=579). Sociodemographic, general health, and mental health characteristics were compared between the two samples. Obtaining a sample of postpartum women online for health research was highly efficient and low-cost. The online sample over-represented those who were younger (aged 25-29 years), were in a de facto relationship, had higher levels of education, spoke only English at home, and were first-time mothers. Members of the online sample were significantly more likely to have poor self-rated health and poor mental health than the nationally representative sample. Health differences remained after adjusting for sociodemographic differences. Potential exists for feasible and low-cost e-epidemiological research with postpartum populations; however, researchers should consider the potential influence of sample nonrepresentativeness. ©Liana S Leach, Peter Butterworth, Carmel Poyser, Philip J Batterham, Louise M Farrer. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 08.03.2017.