Use the Bar Code System to Improve Accuracy of the Patient and Sample Identification.
Chuang, Shu-Hsia; Yeh, Huy-Pzu; Chi, Kun-Hung; Ku, Hsueh-Chen
2018-01-01
In time and correct sample collection were highly related to patient's safety. The sample error rate was 11.1%, because misbranded patient information and wrong sample containers during January to April, 2016. We developed a barcode system of "Specimens Identify System" through process of reengineering of TRM, used bar code scanners, add sample container instructions, and mobile APP. Conclusion, the bar code systems improved the patient safety and created green environment.
A Study on the Perceived Risk of Surface Sample Collection Systems in Proposal Formulation
NASA Technical Reports Server (NTRS)
Sunday, Cecily M.
2012-01-01
This project compares design and proposal elements from multiple proposals and presents conclusions and recommendations for sampling systems. Contributions from this project include a list of common evaluation themes, concept and proposal-related strengths and weaknesses and ways in which self-identified risks relate the evaluation of the mission.
Hemolysis associated with pneumatic tube system transport for blood samples
Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih
2014-01-01
Objective: The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Methods: Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. Results: The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Conclusion: Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis. PMID:24639830
[Water and suspended matter sampling in fresh water networks].
Galas, Chiara; Stellato, Luisa; Barbizzi, Sabrina; Belli, Maria; Sansone, Umberto
2005-01-01
Metals and radionuclides in water systems can be easily adsorbed on suspended matter and, finally, they could eventually accumulate in the aquatic environment. The assessment of the health of a water body needs also sampling of the suspended matter fraction. In this paper sampling systems to characterise contaminants associated with the suspended matter fraction are described, with a particular attention to the collection and preservation of samples. Sampling must be representative, to obtain reliable conclusions. In this context it is stressed the importance of the evaluation of the sampling uncertainty, which contributes to a large extent to the total uncertainty.
Energy storage considerations for a robotic Mars surface sampler
NASA Technical Reports Server (NTRS)
Odonnell, Patricia M.; Cataldo, Robert L.; Gonzalez-Sanabria, Olga D.
1988-01-01
A Mars Rover capable of obtaining surface samples will need a power system for motive power and to power scientific instrumentation. Several different power systems are considered along with a discussion of the location options. The weight and volume advantages of the different systems are described for a particular power profile. The conclusions are that a Mars Rover Sample Return Mission and Extended Mission can be accomplished utilizing photovoltaics and electrochemical storage.
The Design and Testing of a High-Temperature Graphite Dilatometer
1992-06-24
26 11. Data from three-point-bend samples of PAA, phenolic, and furfural resin samples that were...TEMPERATURE (0C) Fig. 11. Data from three-point-bend samples of (a) PAA, (b) phenolic, and (c) furfural resin samples that were precured to 350*C. The max- imum...graphitization tempera- tures (20000C); and furfural resin carbon absorbs less at all temperatures. 28 V. CONCLUSIONS The dilatometer system described
Rutten, Niels; Gonzales, José L.; Elbers, Armin R. W.; Velthuis, Annet G. J.
2012-01-01
Background As low pathogenic avian influenza viruses can mutate into high pathogenic viruses the Dutch poultry sector implemented a surveillance system for low pathogenic avian influenza (LPAI) based on blood samples. It has been suggested that egg yolk samples could be sampled instead of blood samples to survey egg layer farms. To support future decision making about AI surveillance economic criteria are important. Therefore a cost analysis is performed on systems that use either blood or eggs as sampled material. Methodology/Principal Findings The effectiveness of surveillance using egg or blood samples was evaluated using scenario tree models. Then an economic model was developed that calculates the total costs for eight surveillance systems that have equal effectiveness. The model considers costs for sampling, sample preparation, sample transport, testing, communication of test results and for the confirmation test on false positive results. The surveillance systems varied in sampled material (eggs or blood), sampling location (farm or packing station) and location of sample preparation (laboratory or packing station). It is shown that a hypothetical system in which eggs are sampled at the packing station and samples prepared in a laboratory had the lowest total costs (i.e. € 273,393) a year. Compared to this a hypothetical system in which eggs are sampled at the farm and samples prepared at a laboratory, and the currently implemented system in which blood is sampled at the farm and samples prepared at a laboratory have 6% and 39% higher costs respectively. Conclusions/Significance This study shows that surveillance for avian influenza on egg yolk samples can be done at lower costs than surveillance based on blood samples. The model can be used in future comparison of surveillance systems for different pathogens and hazards. PMID:22523543
Excretion and detection of SARS coronavirus and its nucleic acid from digestive system
Wang, Xin-Wei; Li, Jin-Song; Guo, Ting-Kai; Zhen, Bei; Kong, Qing-Xin; Yi, Bin; Li, Zhong; Song, Nong; Jin, Min; Wu, Xiao-Ming; Xiao, Wen-Jun; Zhu, Xiu-Mei; Gu, Chang-Qing; Yin, Jing; Wei, Wei; Yao, Wei; Liu, Chao; Li, Jian-Feng; Ou, Guo-Rong; Wang, Min-Nian; Fang, Tong-Yu; Wang, Gui-Jie; Qiu, Yao-Hui; Wu, Huai-Huan; Chao, Fu-Huan; Li, Jun-Wen
2005-01-01
AIM: To study whether severe acute respiratory syndrome coronavirus (SARS-CoV) could be excreted from digestive system. METHODS: Cell culture and semi-nested RT-PCR were used to detect SARS-CoV and its RNA from 21 stool and urine samples, and a kind of electropositive filter media particles was used to concentrate the virus in 10 sewage samples from two hospitals receiving SARS patients in Beijing in China. RESULTS: It was demonstrated that there was no live SARS-CoV in all samples collected, but the RNA of SARS-CoV could be detected in seven stool samples from SARS patients with any one of the symptoms of fever, malaise, cough, or dyspnea, in 10 sewage samples before disinfection and 3 samples after disinfection from the two hospitals. The RNA could not be detected in urine and stool samples from patients recovered from SARS. CONCLUSION: Nucleic acid of SARS-CoV can be excreted through the stool of patients into sewage system, and the possibility of SARS-CoV transmitting through digestive system cannot be excluded. PMID:16038039
The Recent Developments in Sample Preparation for Mass Spectrometry-Based Metabolomics.
Gong, Zhi-Gang; Hu, Jing; Wu, Xi; Xu, Yong-Jiang
2017-07-04
Metabolomics is a critical member in systems biology. Although great progress has been achieved in metabolomics, there are still some problems in sample preparation, data processing and data interpretation. In this review, we intend to explore the roles, challenges and trends in sample preparation for mass spectrometry- (MS-) based metabolomics. The newly emerged sample preparation methods were also critically examined, including laser microdissection, in vivo sampling, dried blood spot, microwave, ultrasound and enzyme-assisted extraction, as well as microextraction techniques. Finally, we provide some conclusions and perspectives for sample preparation in MS-based metabolomics.
A demonstration of NIOSH push-pull ventilation criteria.
Klein, M K
1987-03-01
This paper summarizes the results of a study performed on an actual chrome plating tank in order to validate criteria for push-pull ventilation systems developed by Huebener and Hughes at NIOSH. Validation of the criteria was made by taking area industrial hygiene samples for hexavalent and total chrome at ten locations around the plating tank. The sampling was performed during actual production runs or while the tank was operating with a dummy load. The sampling data are summarized. The data show that the push-pull system, operating at Huebener's criteria, could control emissions to below the current standards and guidelines. Conclusions and recommendations are included.
2013-01-01
Background Traditional Lot Quality Assurance Sampling (LQAS) designs assume observations are collected using simple random sampling. Alternatively, randomly sampling clusters of observations and then individuals within clusters reduces costs but decreases the precision of the classifications. In this paper, we develop a general framework for designing the cluster(C)-LQAS system and illustrate the method with the design of data quality assessments for the community health worker program in Rwanda. Results To determine sample size and decision rules for C-LQAS, we use the beta-binomial distribution to account for inflated risk of errors introduced by sampling clusters at the first stage. We present general theory and code for sample size calculations. The C-LQAS sample sizes provided in this paper constrain misclassification risks below user-specified limits. Multiple C-LQAS systems meet the specified risk requirements, but numerous considerations, including per-cluster versus per-individual sampling costs, help identify optimal systems for distinct applications. Conclusions We show the utility of C-LQAS for data quality assessments, but the method generalizes to numerous applications. This paper provides the necessary technical detail and supplemental code to support the design of C-LQAS for specific programs. PMID:24160725
Detection of Candida species by nested PCR method in one-humped camels (Camelus dromedarius).
Parin, Ugur; Erbas, Goksel; Kirkan, Sukru; Savasan, Serap; Tugba Yuksel, H; Balat, Gamze
2018-02-01
Systemic fungal diseases are the infections caused by false treatment protocols and generally are not taken into consideration especially in the veterinary field. One-humped camels are found in the western side of the Aegean region of our country and bred for wrestling. The aim of this study is the application of diagnosing systemic fungi infection from camel blood samples by the PCR method. In this study, specific primers for DNA topoisomerase II gene sequences were used. As a result, a systemic fungal infection was detected by the nested PCR method from 10 (20%) out of 50 DNA samples taken from camels located on the western side of the Aegean region. In this study, 3 (30%) samples were identified as Candida albicans, 3 (30%) samples were identified as C. glabrata, and 4 (40%) samples were identified as C. parapsilosis. In conclusion, the 20% positive systemic fungal infection rate in one-humped camels observed in the present study showed that the systemic fungal infections are not taken into considerations in veterinary medicine. Further studies are suggested in order to obtain and to maintain extensive data for systemic fungal diseases in our country for one-humped camels.
Ort, Christoph; Lawrence, Michael G; Rieckermann, Jörg; Joss, Adriano
2010-08-15
The analysis of 87 peer-reviewed journal articles reveals that sampling for pharmaceuticals and personal care products (PPCPs) and illicit drugs in sewers and sewage treatment plant influents is mostly carried out according to existing tradition or standard laboratory protocols. Less than 5% of all studies explicitly consider internationally acknowledged guidelines or methods for the experimental design of monitoring campaigns. In the absence of a proper analysis of the system under investigation, the importance of short-term pollutant variations was typically not addressed. Therefore, due to relatively long sampling intervals, potentially inadequate sampling modes, or insufficient documentation, it remains unclear for the majority of reviewed studies whether observed variations can be attributed to "real" variations or if they simply reflect sampling artifacts. Based on results from previous and current work, the present paper demonstrates that sampling errors can lead to overinterpretation of measured data and ultimately, wrong conclusions. Depending on catchment size, sewer type, sampling setup, substance of interest, and accuracy of analytical method, avoidable sampling artifacts can range from "not significant" to "100% or more" for different compounds even within the same study. However, in most situations sampling errors can be reduced greatly, and sampling biases can be eliminated completely, by choosing an appropriate sampling mode and frequency. This is crucial, because proper sampling will help to maximize the value of measured data for the experimental assessment of the fate of PPCPs as well as for the formulation and validation of mathematical models. The trend from reporting presence or absence of a compound in "clean" water samples toward the quantification of PPCPs in raw wastewater requires not only sophisticated analytical methods but also adapted sampling methods. With increasing accuracy of chemical analyses, inappropriate sampling increasingly represents the major source of inaccuracy. A condensed step-by-step Sampling Guide is proposed as a starting point for future studies.
EVALUATION OF AN AUTOMATED OVOC SAMPLING AND ANALYSIS SYSTEM. (R826372)
The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...
[A quickly methodology for drug intelligence using profiling of illicit heroin samples].
Zhang, Jianxin; Chen, Cunyi
2012-07-01
The aim of the paper was to evaluate a link between two heroin seizures using a descriptive method. The system involved the derivation and gas chromatographic separation of samples followed by a fully automatic data analysis and transfer to a database. Comparisons used the square cosine function between two chromatograms assimilated to vectors. The method showed good discriminatory capabilities. The probability of false positives was extremely slight. In conclusion, this method proved to be efficient and reliable, which appeared suitable for estimating the links between illicit heroin samples.
Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?
Phelan, Michael P.; Reineks, Edmunds Z.; Hustey, Fredric M.; Berriochoa, Jacob P.; Podolsky, Seth R.; Meldon, Stephen; Schold, Jesse D.; Chamberlin, Janelle; Procop, Gary W.
2016-01-01
Introduction Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. Methods The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest®) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. Results During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%–14.6%). Conclusion We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department. PMID:27625719
Evaluation of atopy through an expert system: description of the database.
Ray, P; Vervloet, D; Charpin, D; Gautier, V; Proudhon, H; Redier, H; Godard, P
1995-11-01
In order to understand the medical decisions taken during the initial visit of a new asthmatic patient, a group of experts designed an expert system which provides conclusions about severity, precipitating factors and treatment. Rules for atopy and the assessment of allergic factors have been discussed and implemented in the expert system. Conclusions about severity have been yet validated using an appropriate methodology. The aim of this study was to investigate a sample of 471 patients according to conclusions regarding atopy. A total of 471 cases report forms (CRF) was filled in for adult asthmatic outpatients, seen for the first time in our clinic without emergency situations. Data of each CRF were used by the expert system to draw conclusions. The expert system discerns three patterns for atopy, yes, possible or no. The variables known to reflect different features according to the classification of asthma as atopic or not have been studied. The variables used in the rules for atopy, obviously linked to the conclusion, were not compared. For many medical problems no unique objective solution exists and this is why a group of patients with possible atopy was introduced. Patients with atopy had less severe asthma (P = 0.01), a better FEV1 value (P = 0.0007) and showed their first symptoms of asthma earlier (P = 0.00001) than patients without atopy. The characteristics of the group studied here are consistent with the literature. This could be considered as an indirect validation of the expert system. Moreover, patients with possible atopy show intermediate findings for these variables and it is possible to suggest a 'dose-effect' relationship.
NASA Astrophysics Data System (ADS)
Beck, L.; Wood, B.; Whitney, S.; Rossi, R.; Spanner, M.; Rodriguez, M.; Rodriguez-Ramirez, A.; Salute, J.; Legters, L.; Roberts, D.; Rejmankova, E.; Washino, R.
1993-08-01
This paper describes a procedure whereby remote sensing and geographic information system (GIS) technologies are used in a sample design to study the habitat of Anopheles albimanus, one of the principle vectors of malaria in Central America. This procedure incorporates Landsat-derived land cover maps with digital elevation and road network data to identify a random selection of larval habitats accessible for field sampling. At the conclusion of the sampling season, the larval counts will be used to determine habitat productivity, and then integrated with information on human settlement to assess where people are at high risk of malaria. This aproach would be appropriate in areas where land cover information is lacking and problems of access constrain field sampling. The use of a GIS also permits other data (such as insecticide spraying data) to the incorporated in the sample design as they arise. This approach would also be pertinent for other tropical vector-borne diseases, particularly where human activities impact disease vector habitat.
Hosseininasab, Abufazel; Mohammadi, Mohammadreza; Jouzi, Samira; Esmaeilinasab, Maryam; Delavar, Ali
2016-01-01
Objective: This study aimed to provide a normative study documenting how 114 five-seven year-old non-patient Iranian children respond to the Rorschach test. We compared this especial sample to international normative reference values for the Comprehensive System (CS). Method: One hundred fourteen 5- 7- year-old non-patient Iranian children were recruited from public schools. Using five child and adolescent samples from five countries, we compared Iranian Normative Reference Data- based on reference means and standard deviations for each sample. Results: Findings revealed that how the scores in each sample were distributed and how the samples were compared across variables in eight Rorschach Comprehensive System (CS) clusters. We reported all descriptive statistics such as reference mean and standard deviation for all variables. Conclusion: Iranian clinicians could rely on country specific or “local norms” when assessing children. We discourage Iranian clinicians to use many CS scores to make nomothetic, score-based inferences about psychopathology in children and adolescents. PMID:27928247
The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...
Genie Inference Engine Rule Writer’s Guide.
1987-08-01
33 APPENDIX D. Animal Bootstrap File.............................................................. 39...APPENDIX E. Sample Run of Animal Identification Expert System.......................... 43 APPENDIX F. Numeric Test Knowledge Base...and other data s.tructures stored in the knowledge base (KB), queries the user for input, and draws conclusions. Genie (GENeric Inference Engine) is
NASA Technical Reports Server (NTRS)
Russell, John M.
1993-01-01
Many helium mass spectrometer leak detectors at KSC employ sampling systems that feature hand held sniffer probes. Authors of general leakage-testing literature recommend sniffer probes for leak location but not for quantitative leakage measurement. Their use in the latter application at KSC involves assumptions that may be subtle. The purpose of the research effort reported herein was to establish the significance of indicated leak rates displayed by sniffer-probe equipped leak detectors and to determine whether the use of alternative hardware or testing procedures may reduce the uncertainty of leakage measurements made with them. The report classifies probe-type sampling systems for helium leak detectors according to their internal plumbing (direct or branched), presents a basic analysis of the fluid dynamics in the sampling system in the branched-conduit case, describes the usual test method for measuring the internal supply-to-sample flowrate ratio (a.k.a permeation ratio), and describes a concept for a sponge-tipped probe whose external supply-to-sample flowrate ratio promises to be lower than that of a simple-ended probe. One conclusion is that the main source of uncertainty in the use of probe-type sampling systems for leakage measurement is uncertainty in the external supply-to-sample flowrate ratio. In contrast, the present method for measuring the internal supply-to-sample flowrate ratio is quantitative and satisfactory. The implication is that probes of lower external supply-to-sample flowrate ratio must be developed before this uncertainty may be reduced significantly.
Software Engineering Frameworks: Textbooks vs. Student Perceptions
ERIC Educational Resources Information Center
McMaster, Kirby; Hadfield, Steven; Wolthuis, Stuart; Sambasivam, Samuel
2012-01-01
This research examines the frameworks used by Computer Science and Information Systems students at the conclusion of their first semester of study of Software Engineering. A questionnaire listing 64 Software Engineering concepts was given to students upon completion of their first Software Engineering course. This survey was given to samples of…
Abu Bakar, Nur Faizah; Fudholi, Ahmad; Ruslan, Mohd Hafidz; Saroeun, Im
2015-01-01
The content of 12 elements in Cambodian dried striped snakehead fish was determined using inductively coupled plasma mass spectrometry. The present study compares the level of the trace toxic metals and nutritional trace elements in the fish processed using solar drying system (SDS) and open sun drying (OSD). The skin of SDS fish has lower level of As, Pb, and Cd compared to the OSD sample. As such, the flesh of the fish accumulated higher amount of toxic metals during OSD compared to SDS. However, arsenic was detected in both samples within the safe limit. The nutritional elements (Fe, Mn, Mg, Se, Mo, Cu, Ni, and Cr) were higher in the skin sample SDS fish compared to OSD fish. These beneficial metals were not accumulated in the flesh sample SDS fish demonstrating lower level compared to drying under conventional system. The reddish coloration of the SDS fish was due to the presence of high Cu content in both the skin and flesh samples which possibly account for no mold formation 5 days after packaging. As conclusion, drying of Cambodian C. striata using solar-assisted system has proven higher content of the nutritious elements compared to using the conventional system despite only slight difference in the toxic metals level between the two systems. PMID:25688274
Development and testing of a portable wind sensitive directional air sampler
NASA Technical Reports Server (NTRS)
Deyo, J.; Toma, J.; King, R. B.
1975-01-01
A portable wind sensitive directional air sampler was developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. The unit, designated Air Scout, receives wind direction signals from an associated wind vane. Air samples are collected on filter slides using a standard high volume air sampler drawing air through a porting arrangement which tracks the wind direction and permits collection of discrete samples. A preset timer controls the length of time each filter is in the sampling position. At the conclusion of the sampling period a new filter is automatically moved into sampling position displacing the previous filter to a storage compartment. Thus the Air Scout may be set up at a field location, loaded with up to 12 filter slides, and left to acquire air samples automatically, according to the wind, at any timer interval desired from 1 to 30 hours.
Accuracy Evaluation of Five Blood Glucose Monitoring Systems: The North American Comparator Trial
Halldorsdottir, Solveig; Warchal-Windham, Mary Ellen; Wallace, Jane F.; Pardo, Scott; Parkes, Joan Lee; Simmons, David A.
2013-01-01
Background This study evaluated differences in accuracy between the CONTOUR® NEXT EZ (EZ) blood glucose monitoring system (BGMS) and four other BGMSs [ACCU-CHEK® Aviva (ACAP), FreeStyle Freedom Lite® (FFL), ONE TOUCH® Ultra®2 (OTU2), and TRUEtrack® (TT)]. Methods Up to three capillary blood samples (N = 393) were collected from 146 subjects with and without diabetes. One sample per subject was tested with fresh (natural) blood; the other samples were glycolyzed to lower blood glucose to <70 mg/dl. Meter results were compared with results from plasma from the same sample tested on a Yellow Springs Instruments (YSI) 2300 STAT Plus™ glucose analyzer. Blood glucose monitoring system accuracy was compared using mean absolute relative difference (MARD; from laboratory reference method results) and other analyses. Separate analyses on fresh (natural) samples only were conducted to determine potential effects of glycolysis on MARD values of systems utilizing glucose-oxidase-based test strip chemistry. Results Across the tested glucose range, the EZ had the lowest MARD of 4.7%; the ACAP, FFL, OTU2, and TT had MARD values of 6.3%, 18.3%, 23.4%, and 26.2%, respectively. For samples with glucose concentrations <70 mg/dl, the EZ had the lowest MARD (0.65%), compared with the ACAP (2.5%), FFL (18.3%), OTU2 (22.4%), and TT (33.2%) systems. Conclusions The EZ had the lowest MARD across the tested glucose ranges when compared with four other BGMSs when all samples were analyzed as well as when natural samples only were analyzed. PMID:24124957
Zhu, Li-Wei; Yang, Xue-Mei; Xu, Xiao-Qin; Xu, Jian; Lu, Huang-Jun; Yan, Li-Xing
2008-10-01
This study was aimed to analyze the results of false positive reaction in bacterial detection of blood samples with BacT/ALERT 3D system, to evaluate the specificity of this system, and to decrease the false positive reaction. Each reaction flasks in past five years were processed for bacteria isolation and identification. When the initial cultures were positive, the remaining samples and the corresponding units were recultured if still available. 11395 blood samples were detected. It is worthy of note that the incubator temperature should be stabilized, avoiding fluctuation; when the cultures were alarmed, the reaction flasks showed be kept some hours for further incubation so as to trace a sharply increasing signal to support the judgement of true bacterial growth. The results indicated that 122 samples (1.07%) wee positive at initial culture, out of them 107 samples (88.7%) were found bacterial, and 15 samples (12.3%) were found nothing. The detection curves of positive samples resulted from bacterial growth showed ascent. In conclusion, maintenance of temperature stability and avoidance of temperature fluctuation in incubator could decrease the occurrence of false-positive reaction in detection process. The reaction flasks with positive results at initial culture should be recultured, and whether existence of a sharply ascending logarilhimic growth phase in bacterial growth curve should be further detected, which are helpful to distinguish false-positive reactions from true positive, and thus increase the specificity of the BacT/ALERT system.
Field monitoring versus individual miner dosimetry of radon daughter products in mines.
Domański, T; Kluszczyński, D; Olszewski, J; Chruscielewski, W
1989-01-01
The paper presents the results realised simultaneously by two different and independent systems of measurement of an assessment of miners' exposure to radon daughter products which naturally occur in the air of mines. The first one, called the Air Sampling System (ASS), was based on the field monitoring of radon progeny in air, the second one, called the Individual Dosimetry System (IDS), was based on the individual dosimeters worn by miners. Experimental comparison of these two systems has been conducted for six years in eleven Polish underground metal-ore mines. This study reveals that no correlation exists between the concentration and annual miners' exposures evaluated by the ASS and IDS. The ratio ASS/IDS for mine population varies from 11.0 to 0.14 in respect of annual concentration means, and in respect to annual exposures, this ratio varies from 4.5 to 0.14. The conclusion to be drawn from six years' observation and comparison of both systems is that correct and true evaluation of miners' exposure to radon progeny can be made only by the use of the Individual Dosimetry System, since the Air Sampling System is too sensitive and too dependent on the Strategy of sampling and its radiation.
ERIC Educational Resources Information Center
Baenen, Nancy
2011-01-01
The longitudinal study of the 2005-06 preschool in Wake County Public School System (WCPSS) found short-term gains during the preschool year, but limited impact by kindergarten and no average impact by the end of 3rd grade on achievement, retention rates, special education placements, or attendance. Small sample sizes limit conclusions that can be…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sexton, L.
2012-06-06
Environmental sampling has become a key component of International Atomic Energy Agency (IAEA) safeguards approaches since its approval for use in 1996. Environmental sampling supports the IAEA's mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a Nation State. Swipe sampling is the most commonly used method for the collection of environmental samples from bulk handling facilities. However, augmenting swipe samples with an air monitoring system, which could continuously draw samples from the environment of bulk handling facilities, could improve the possibility of the detection of undeclared activities. Continuous sampling offers the opportunity tomore » collect airborne materials before they settle onto surfaces which can be decontaminated, taken into existing duct work, filtered by plant ventilation, or escape via alternate pathways (i.e. drains, doors). Researchers at the Savannah River National Laboratory and Oak Ridge National Laboratory have been working to further develop an aerosol collection technology that could be installed at IAEA safeguarded bulk handling facilities. The addition of this technology may reduce the number of IAEA inspector visits required to effectively collect samples. The principal sample collection device is a patented Aerosol Contaminant Extractor (ACE) which utilizes electrostatic precipitation principles to deposit particulates onto selected substrates. Recent work has focused on comparing traditional swipe sampling to samples collected via an ACE system, and incorporating tamper resistant and tamper indicating (TRI) technologies into the ACE system. Development of a TRI-ACE system would allow collection of samples at uranium/plutonium bulk handling facilities in a manner that ensures sample integrity and could be an important addition to the international nuclear safeguards inspector's toolkit. This work was supported by the Next Generation Safeguards Initiative (NGSI), Office of Nonproliferation and International Security (NIS), National Nuclear Security Administration (NNSA).« less
Hide, Geoff; Hughes, Jacqueline M; McNuff, Robert
2003-01-01
Background The rapid expansion in the availability of genome and DNA sequence information has opened up new possibilities for the development of methods for detecting free-living protozoa in environmental samples. The protozoan Blepharisma japonicum was used to investigate a rapid and simple detection system based on polymerase chain reaction amplification (PCR) from organisms immobilised on FTA paper. Results Using primers designed from the α-tubulin genes of Blepharisma, specific and sensitive detection to the equivalent of a single Blepharisma cell could be achieved. Similar detection levels were found using water samples, containing Blepharisma, which were dried onto Whatman FTA paper. Conclusion This system has potential as a sensitive convenient detection system for Blepharisma and could be applied to other protozoan organisms. PMID:14516472
Veličković, Dušan; Chu, Rosalie K.; Carrell, Alyssa A.; ...
2017-12-06
One critical aspect of mass spectrometry imaging (MSI) is the need to confidently identify detected analytes. While orthogonal tandem MS (e.g., LC–MS 2) experiments from sample extracts can assist in annotating ions, the spatial information about these molecules is lost. Accordingly, this could cause mislead conclusions, especially in cases where isobaric species exhibit different distributions within a sample. In this Technical Note, we employed a multimodal imaging approach, using matrix assisted laser desorption/ionization (MALDI)-MSI and liquid extraction surface analysis (LESA)-MS 2I, to confidently annotate and localize a broad range of metabolites involved in a tripartite symbiosis system of moss, cyanobacteria,more » and fungus. In conclusion, we found that the combination of these two imaging modalities generated very congruent ion images, providing the link between highly accurate structural information onfered by LESA and high spatial resolution attainable by MALDI. These results demonstrate how this combined methodology could be very useful in differentiating metabolite routes in complex systems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veličković, Dušan; Chu, Rosalie K.; Carrell, Alyssa A.
One critical aspect of mass spectrometry imaging (MSI) is the need to confidently identify detected analytes. While orthogonal tandem MS (e.g., LC–MS 2) experiments from sample extracts can assist in annotating ions, the spatial information about these molecules is lost. Accordingly, this could cause mislead conclusions, especially in cases where isobaric species exhibit different distributions within a sample. In this Technical Note, we employed a multimodal imaging approach, using matrix assisted laser desorption/ionization (MALDI)-MSI and liquid extraction surface analysis (LESA)-MS 2I, to confidently annotate and localize a broad range of metabolites involved in a tripartite symbiosis system of moss, cyanobacteria,more » and fungus. In conclusion, we found that the combination of these two imaging modalities generated very congruent ion images, providing the link between highly accurate structural information onfered by LESA and high spatial resolution attainable by MALDI. These results demonstrate how this combined methodology could be very useful in differentiating metabolite routes in complex systems.« less
Ten years of preanalytical monitoring and control: Synthetic Balanced Score Card Indicator
López-Garrigós, Maite; Flores, Emilio; Santo-Quiles, Ana; Gutierrez, Mercedes; Lugo, Javier; Lillo, Rosa; Leiva-Salinas, Carlos
2015-01-01
Introduction Preanalytical control and monitoring continue to be an important issue for clinical laboratory professionals. The aim of the study was to evaluate a monitoring system of preanalytical errors regarding not suitable samples for analysis, based on different indicators; to compare such indicators in different phlebotomy centres; and finally to evaluate a single synthetic preanalytical indicator that may be included in the balanced scorecard management system (BSC). Materials and methods We collected individual and global preanalytical errors in haematology, coagulation, chemistry, and urine samples analysis. We also analyzed a synthetic indicator that represents the sum of all types of preanalytical errors, expressed in a sigma level. We studied the evolution of those indicators over time and compared indicator results by way of the comparison of proportions and Chi-square. Results There was a decrease in the number of errors along the years (P < 0.001). This pattern was confirmed in primary care patients, inpatients and outpatients. In blood samples, fewer errors occurred in outpatients, followed by inpatients. Conclusion We present a practical and effective methodology to monitor unsuitable sample preanalytical errors. The synthetic indicator results summarize overall preanalytical sample errors, and can be used as part of BSC management system. PMID:25672466
2012-01-01
Background Mortality estimates can measure and monitor the impacts of conflict on a population, guide humanitarian efforts, and help to better understand the public health impacts of conflict. Vital statistics registration and surveillance systems are rarely functional in conflict settings, posing a challenge of estimating mortality using retrospective population-based surveys. Results We present a two-stage cluster sampling method for application in population-based mortality surveys. The sampling method utilizes gridded population data and a geographic information system (GIS) to select clusters in the first sampling stage and Google Earth TM imagery and sampling grids to select households in the second sampling stage. The sampling method is implemented in a household mortality study in Iraq in 2011. Factors affecting feasibility and methodological quality are described. Conclusion Sampling is a challenge in retrospective population-based mortality studies and alternatives that improve on the conventional approaches are needed. The sampling strategy presented here was designed to generate a representative sample of the Iraqi population while reducing the potential for bias and considering the context specific challenges of the study setting. This sampling strategy, or variations on it, are adaptable and should be considered and tested in other conflict settings. PMID:22540266
El Amiri, B; Sousa, N M; Alvarez Oxiley, A; Hadarbach, D; Beckers, J F
2015-04-01
In the present study, four RIA systems (RIA-1 to -4) based on two antisera raised against ovine pregnancy-associated glycoproteins (ovPAGs), combined with an ovine or a bovine PAG tracer were used to measure PAG concentrations in plasma and milk samples of dairy ewes. Blood and milk samples were collected on different days of gestation: 0, 18, 20, 22, 25, 28, 32, 42, and 49. From day 20 onward, the PAG in plasma could be detected in all pregnant ewes using the four RIA systems. By using milk, except for RIA-1, the other systems showed a sensitivity of 100% from day 28 of gestation onward. In plasma, PAG concentrations were higher in multiple than in single pregnancies, while no clear relationship was observed in milk. In conclusion, milk is a good alternative to plasma for early pregnancy diagnosis in sheep from day 28 to day 42. Copyright © 2014 Elsevier Ltd. All rights reserved.
Automation in photogrammetry: Recent developments and applications (1972-1976)
Thompson, M.M.; Mikhail, E.M.
1976-01-01
An overview of recent developments in the automation of photogrammetry in various countries is presented. Conclusions regarding automated photogrammetry reached at the 1972 Congress in Ottawa are reviewed first as a background for examining the developments of 1972-1976. Applications are described for each country reporting significant developments. Among fifteen conclusions listed are statements concerning: the widespread practice of equipping existing stereoplotters with simple digitizers; the growing tendency to use minicomputers on-line with stereoplotters; the optimization of production of digital terrain models by progressive sampling in stereomodels; the potential of digitization of a photogrammetric model by density correlation on epipolar lines; the capabilities and economic aspects of advanced systems which permit simultaneous production of orthophotos, contours, and digital terrain models; the economy of off-line orthophoto systems; applications of digital image processing; automation by optical techniques; applications of sensors other than photographic imagery, and the role of photogrammetric phases in a completely automated cartographic system. ?? 1976.
Fossil group origins. III. The relation between optical and X-ray luminosities
NASA Astrophysics Data System (ADS)
Girardi, M.; Aguerri, J. A. L.; De Grandi, S.; D'Onghia, E.; Barrena, R.; Boschin, W.; Méndez-Abreu, J.; Sánchez-Janssen, R.; Zarattini, S.; Biviano, A.; Castro-Rodriguez, N.; Corsini, E. M.; del Burgo, C.; Iglesias-Páramo, J.; Vilchez, J. M.
2014-05-01
Aims: This study is part of the Fossil group origins (FOGO) project which aims to carry out a systematic and multiwavelength study of a large sample of fossil systems. Here we focus on the relation between the optical luminosity (Lopt) and X-ray luminosity (LX). Methods: Out of a total sample of 28 candidate fossil systems, we consider a sample of 12 systems whose fossil classification has been confirmed by a companion study. They are compared with the complementary sample of 16 systems whose fossil nature has not been confirmed and with a subsample of 102 galaxy systems from the RASS-SDSS galaxy cluster survey. Fossil and normal systems span the same redshift range 0
Fagge, Timothy J; Barclay, G Robin; Stove, G Colin; Stove, Gordon; Robinson, Michael J; Head, Mark W; Ironside, James W; Turner, Marc L
2007-01-01
Background Sub-clinical variant Creutzfeldt-Jakob disease (vCJD) infection and reports of vCJD transmission through blood transfusion emphasise the need for blood screening assays to ensure the safety of blood and transplanted tissues. Most assays aim to detect abnormal prion protein (PrPSc), although achieving required sensitivity is a challenge. Methods We have used innovative Atomic Dielectric Resonance Spectroscopy (ADRS), which determines dielectric properties of materials which are established by reflectivity and penetration of radio/micro waves, to analyse blood samples from patients and controls to identify characteristic ADR signatures unique to blood from vCJD and to sCJD patients. Initial sets of blood samples from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) were screened as training samples to determine group-specific ADR characteristics, and provided a basis for classification of blinded sets of samples. Results Blood sample groups from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) screened by ADRS were classified with 100% specificity and sensitivity, discriminating these by a co-variance expert analysis system. Conclusion ADRS appears capable of recognising and discriminating serum samples from vCJD, sCJD, non-CJD neurological diseases, and normal healthy adults, and might be developed to provide a system for primary screening or confirmatory assay complementary to other screening systems. PMID:17760958
NASA Technical Reports Server (NTRS)
Baker, G. R.; Fethe, T. P.
1975-01-01
Research in the application of remotely sensed data from LANDSAT or other airborne platforms to the efficient management of a large timber based forest industry was divided into three phases: (1) establishment of a photo/ground sample correlation, (2) investigation of techniques for multi-spectral digital analysis, and (3) development of a semi-automated multi-level sampling system. To properly verify results, three distinct test areas were selected: (1) Jacksonville Mill Region, Lower Coastal Plain, Flatwoods, (2) Pensacola Mill Region, Middle Coastal Plain, and (3) Mississippi Mill Region, Middle Coastal Plain. The following conclusions were reached: (1) the probability of establishing an information base suitable for management requirements through a photo/ground double sampling procedure, alleviating the ground sampling effort, is encouraging, (2) known classification techniques must be investigated to ascertain the level of precision possible in separating the many densities involved, and (3) the multi-level approach must be related to an information system that is executable and feasible.
NASA Astrophysics Data System (ADS)
Driandanu, Galih; Surarso, Bayu; Suryono
2018-02-01
A radio frequency identification (RFID) has obtained increasing attention with the emergence of various applications. This study aims to examine the implementation of rule based expert system supported by RFID technology into a monitoring information system of drug supply in a hospital. This research facilitates in monitoring the real time drug supply by using data sample from the hospital pharmacy. This system able to identify and count the number of drug and provide warning and report in real time. the conclusion is the rule based expert system and RFID technology can facilitate the performance in monitoring the drug supply quickly and precisely.
Goutziana, Georgia; Mouchtouri, Varvara A; Karanika, Maria; Kavagias, Antonios; Stathakis, Nikolaos E; Gourgoulianis, Kostantinos; Kremastinou, Jenny; Hadjichristodoulou, Christos
2008-01-01
Background Legionnaires' disease continues to be a public health concern in passenger ships. This study was scheduled in order to investigate Legionella spp. colonization of water distribution systems (WDS), recreational pools, and air-conditioning systems on board ferries and cruise ships in an attempt to identify risk factors for Legionella spp. colonization associated with ship water systems and water characteristics. Methods Water systems of 21 ferries and 10 cruise ships including WDS, air conditioning systems and pools were investigated for the presence of Legionella spp. Results The 133 samples collected from the 10 cruise ships WDS, air conditioning systems and pools were negative for Legionella spp. Of the 21 ferries WDS examined, 14 (66.7%) were legionellae-positive. A total of 276 samples were collected from WDS and air conditioning systems. Legionella spp. was isolated from 37.8% of the hot water samples and 17.5% of the cold water samples. Of the total 96 positive isolates, 87 (90.6%) were L. pneumophila. Legionella spp. colonization was positively associated with ship age. The temperature of the hot water samples was negatively associated with colonization of L. pneumophila serogroup (sg) 1 and that of L. pneumophila sg 2 to 14. Increases in pH ≥7.8 and total plate count ≥400 CFU/L, correlated positively with the counts of L. pneumophila sg 2 to 14 and Legionella spp. respectively. Free chlorine of ≥0.2 mg/L inhibited colonization of Legionella spp. Conclusion WDS of ferries can be heavily colonized by Legionella spp. and may present a risk of Legionnaires' disease for passengers and crew members. Guidelines and advising of Legionnaires' disease prevention regarding ferries are needed, in particular for operators and crew members. PMID:19025638
Nassau, Jack H.; Tien, Karen; Fritz, Gregory K.
2012-01-01
Objective Provide an orientation to psychoneuroimmunology, a rationale for including assessments of immune function in intervention studies of pediatric chronic illness, review the current literature, and provide recommendations for future research. Methods Using electronic searches and previous reviews, selected and reviewed published studies in which immunological changes related to psychological interventions were assessed in pediatric samples. Results Eight studies were identified and included in the review. These utilized a range of interventions (e.g., disclosure and hypnosis) and included a variety of pediatric samples (e.g., those with asthma, HIV infection, or lupus). Conclusions Results suggest that psychological intervention can influence immune function in pediatric samples. Recommendations for advancing our knowledge by studying populations for whom the immune system plays an active role in disease pathophysiology, measuring disease-relevant immune mediators, studying pediatric patients under times of stress, and focusing on interventions aimed at altering the stress system are provided. PMID:17848391
Earth recovery mode analysis for a Martian sample return mission
NASA Technical Reports Server (NTRS)
Green, J. P.
1978-01-01
The analysis has concerned itself with evaluating alternative methods of recovering a sample module from a trans-earth trajectory originating in the vicinity of Mars. The major modes evaluated are: (1) direct atmospheric entry from trans-earth trajectory; (2) earth orbit insertion by retropropulsion; and (3) atmospheric braking to a capture orbit. In addition, the question of guided vs. unguided entry vehicles was considered, as well as alternative methods of recovery after orbit insertion for modes (2) and (3). A summary of results and conclusions is presented. Analytical results for aerodynamic and propulsive maneuvering vehicles are discussed. System performance requirements and alternatives for inertial systems implementation are also discussed. Orbital recovery operations and further studies required to resolve the recovery mode issue are described.
Cahill, John F.; Kertesz, Vilmos; Van Berkel, Gary J.
2016-02-01
Here, laser microdissection coupled directly with mass spectrometry provides the capability of on-line analysis of substrates with high spatial resolution, high collection efficiency, and freedom on shape and size of the sampling area. Establishing the merits and capabilities of the different sampling modes that the system provides is necessary in order to select the best sampling mode for characterizing analytically challenging samples. The capabilities of laser ablation spot sampling, laser ablation raster sampling, and laser 'cut and drop' sampling modes of a hybrid optical microscopy/laser ablation liquid vortex capture electrospray ionization mass spectrometry system were compared for the analysis ofmore » single cells and tissue. Single Chlamydomonas reinhardtii cells were monitored for their monogalactosyldiacylglycerol (MGDG) and diacylglyceryltrimethylhomo-Ser (DGTS) lipid content using the laser spot sampling mode, which was capable of ablating individual cells (4-15 m) even when agglomerated together. Turbid Allium Cepa cells (150 m) having unique shapes difficult to precisely measure using the other sampling modes could be ablated in their entirety using laser raster sampling. Intact microdissections of specific regions of a cocaine-dosed mouse brain tissue were compared using laser 'cut and drop' sampling. Since in laser 'cut and drop' sampling whole and otherwise unmodified sections are captured into the probe, 100% collection efficiencies were achieved. Laser ablation spot sampling has the highest spatial resolution of any sampling mode, while laser ablation raster sampling has the highest sampling area adaptability of the sampling modes. In conclusion, laser ablation spot sampling has the highest spatial resolution of any sampling mode, useful in this case for the analysis of single cells. Laser ablation raster sampling was best for sampling regions with unique shapes that are difficult to measure using other sampling modes. Laser 'cut and drop' sampling can be used for cases where the highest sensitivity is needed, for example, monitoring drugs present in trace amounts in tissue.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cahill, John F.; Kertesz, Vilmos; Van Berkel, Gary J.
Here, laser microdissection coupled directly with mass spectrometry provides the capability of on-line analysis of substrates with high spatial resolution, high collection efficiency, and freedom on shape and size of the sampling area. Establishing the merits and capabilities of the different sampling modes that the system provides is necessary in order to select the best sampling mode for characterizing analytically challenging samples. The capabilities of laser ablation spot sampling, laser ablation raster sampling, and laser 'cut and drop' sampling modes of a hybrid optical microscopy/laser ablation liquid vortex capture electrospray ionization mass spectrometry system were compared for the analysis ofmore » single cells and tissue. Single Chlamydomonas reinhardtii cells were monitored for their monogalactosyldiacylglycerol (MGDG) and diacylglyceryltrimethylhomo-Ser (DGTS) lipid content using the laser spot sampling mode, which was capable of ablating individual cells (4-15 m) even when agglomerated together. Turbid Allium Cepa cells (150 m) having unique shapes difficult to precisely measure using the other sampling modes could be ablated in their entirety using laser raster sampling. Intact microdissections of specific regions of a cocaine-dosed mouse brain tissue were compared using laser 'cut and drop' sampling. Since in laser 'cut and drop' sampling whole and otherwise unmodified sections are captured into the probe, 100% collection efficiencies were achieved. Laser ablation spot sampling has the highest spatial resolution of any sampling mode, while laser ablation raster sampling has the highest sampling area adaptability of the sampling modes. In conclusion, laser ablation spot sampling has the highest spatial resolution of any sampling mode, useful in this case for the analysis of single cells. Laser ablation raster sampling was best for sampling regions with unique shapes that are difficult to measure using other sampling modes. Laser 'cut and drop' sampling can be used for cases where the highest sensitivity is needed, for example, monitoring drugs present in trace amounts in tissue.« less
NASA Technical Reports Server (NTRS)
Romanoff, Steven
1991-01-01
Cross-cultural, village-level, and farmer surveys have been used with a geographical information system to describe the distribution and relative importance of cassava (manioc, yuca, Manihot esculenta) in its cultural, economic, and ecological contexts. It presents examples of data management for mapping, sample selection, cross-tabulation of characteristics, combination of data types for indices and hypothesis testing. The methods used are reviewed, and some of the main conclusions of the study are presented.
Jáčová, Jaroslava; Gardlo, Alžběta; Friedecký, David; Adam, Tomáš; Dimandja, Jean-Marie D
2017-08-18
Orthogonality is a key parameter that is used to evaluate the separation power of chromatography-based two-dimensional systems. It is necessary to scale the separation data before the assessment of the orthogonality. Current scaling approaches are sample-dependent, and the extent of the retention space that is converted into a normalized retention space is set according to the retention times of the first and last analytes contained in a unique sample to elute. The presence or absence of a highly retained analyte in a sample can thus significantly influence the amount of information (in terms of the total amount of separation space) contained in the normalized retention space considered for the calculation of the orthogonality. We propose a Whole Separation Space Scaling (WOSEL) approach that accounts for the whole separation space delineated by the analytical method, and not the sample. This approach enables an orthogonality-based evaluation of the efficiency of the analytical system that is independent of the sample selected. The WOSEL method was compared to two currently used orthogonality approaches through the evaluation of in silico-generated chromatograms and real separations of human biofluids and petroleum samples. WOSEL exhibits sample-to-sample stability values of 3.8% on real samples, compared to 7.0% and 10.1% for the two other methods, respectively. Using real analyses, we also demonstrate that some previously developed approaches can provide misleading conclusions on the overall orthogonality of a two-dimensional chromatographic system. Copyright © 2017 Elsevier B.V. All rights reserved.
TOISHI, Yuko; TSUNODA, Nobuo; NAGATA, Shun-ichi; KIRISAWA, Rikio; NAGAOKA, Kentaro; WATANABE, Gen; YANAGAWA, Yojiro; KATAGIRI, Seiji; TAYA, Kazuyoshi
2017-01-01
Testosterone (T) concentration is a useful indicator of reproductive function in male animals. However, T concentration is not usually measured in veterinary clinics, partly due to the unavailability of reliable and rapid assays for animal samples. In this study, a rapid chemiluminescent enzyme immunoassay system (CLEIA system) that was developed for the measurement of T concentration in humans use was validated for stallion blood samples. First, serum T concentrations were measured using the CLEIA system and compared with those measured by a fluoroimmunoassay that has been validated for use in stallions. The serum T concentrations measured by the two methods were highly correlated (r = 0.9865, n = 56). Second, to validate the use of whole blood as assay samples, T concentrations in whole blood and in the serum were measured by the CLEIA system. T concentrations in both samples were highly correlated (r = 0.9665, n = 64). Finally, to evaluate the practical value of the CLEIA system in clinical settings, T concentrations were measured in three stallions with reproductive abnormalities after the administration of human chorionic gonadotropin (hCG). Two stallions with small or absent testes in the scrotum showed an increase in T production in response to hCG administration and one stallion with seminoma did not. In conclusion, the CLEIA system was found to be a rapid and reliable tool for measuring T concentrations in stallions and may improve reproductive management in clinical settings and in breeding studs. PMID:29129877
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veličković, Dušan; Chu, Rosalie K.; Carrell, Alyssa A.
One critical aspect of mass spectrometry imaging (MSI) is the need to confidently identify detected analytes. While orthogonal tandem MS (e.g., LC-MS 2) experiments from sample extracts can assist in annotating ions, the spatial information about these molecules is lost. Accordingly, this could cause mislead conclusions, especially in cases where isobaric species exhibit different distributions within a sample. In this Technical Note, we employed a multimodal imaging approach, using matrix assisted laser desorption/ionization (MALDI)-MSI and liquid extraction surface analysis (LESA)-MS 2I, to confidently annotate and One critical aspect of mass spectrometry imaging (MSI) is the need to confidently identify detectedmore » analytes. While orthogonal tandem MS (e.g., LC-MS2) experiments from sample extracts can assist in annotating ions, the spatial information about these molecules is lost. Accordingly, this could cause mislead conclusions, especially in cases where isobaric species exhibit different distributions within a sample. In this Technical Note, we employed a multimodal imaging approach, using matrix assisted laser desorption/ionization (MALDI)-MSI and liquid extraction surface analysis (LESA)-MS 2I, to confidently annotate and localize a broad range of metabolites involved in a tripartite symbiosis system of moss, cyanobacteria, and fungus. We found that the combination of these two imaging modalities generated very congruent ion images, providing the link between highly accurate structural information onfered by LESA and high spatial resolution attainable by MALDI. These results demonstrate how this combined methodology could be very useful in differentiating metabolite routes in complex systems.« less
Social media for intelligence: research, concepts, and results
NASA Astrophysics Data System (ADS)
Franke, Ulrik; Rosell, Magnus
2016-05-01
When sampling part of the enormous amounts of social media data it is important to consider whether the sample is representative. Any method of studying the sampled data is also prone to bias. Sampling and bias aside the data may be generated with malicious intent, such as deception. Deception is a complicated (broad, situational, vague) concept. It seems improbable that an automated computer system would be able to find deception as such. Instead, we argue that the role of a system would be to aid the human analyst by detecting indicators, or clues, of (potential) deception. Indicators could take many forms and are typically neither necessary nor sufficient for there to be an actual deception. However, by using one or combining several of them a human may reach conclusions. Indicators are not necessarily dependent and will be added to or removed from the analysis depending on the circumstances. This modularity can help in counteracting/alleviating attacks on the system by an adversary. If we become aware that an indicator is compromised we can remove it from the analysis and/or replace it with a more sophisticated method that give us a similar indication.
Evaluation of Existing Methods for Human Blood mRNA Isolation and Analysis for Large Studies
Meyer, Anke; Paroni, Federico; Günther, Kathrin; Dharmadhikari, Gitanjali; Ahrens, Wolfgang; Kelm, Sørge; Maedler, Kathrin
2016-01-01
Aims Prior to implementing gene expression analyses from blood to a larger cohort study, an evaluation to set up a reliable and reproducible method is mandatory but challenging due to the specific characteristics of the samples as well as their collection methods. In this pilot study we optimized a combination of blood sampling and RNA isolation methods and present reproducible gene expression results from human blood samples. Methods The established PAXgeneTM blood collection method (Qiagen) was compared with the more recent TempusTM collection and storing system. RNA from blood samples collected by both systems was extracted on columns with the corresponding Norgen and PAX RNA extraction Kits. RNA quantity and quality was compared photometrically, with Ribogreen and by Real-Time PCR analyses of various reference genes (PPIA, β-ACTIN and TUBULIN) and exemplary of SIGLEC-7. Results Combining different sampling methods and extraction kits caused strong variations in gene expression. The use of PAXgeneTM and TempusTM collection systems resulted in RNA of good quality and quantity for the respective RNA isolation system. No large inter-donor variations could be detected for both systems. However, it was not possible to extract sufficient RNA of good quality with the PAXgeneTM RNA extraction system from samples collected by TempusTM collection tubes. Comparing only the Norgen RNA extraction methods, RNA from blood collected either by the TempusTM or PAXgeneTM collection system delivered sufficient amount and quality of RNA, but the TempusTM collection delivered higher RNA concentration compared to the PAXTM collection system. The established Pre-analytix PAXgeneTM RNA extraction system together with the PAXgeneTM blood collection system showed lowest CT-values, i.e. highest RNA concentration of good quality. Expression levels of all tested genes were stable and reproducible. Conclusions This study confirms that it is not possible to mix or change sampling or extraction strategies during the same study because of large variations of RNA yield and expression levels. PMID:27575051
Baumstark, Annette; Pleus, Stefan; Haug, Cornelia; Tesar, Martina; Freckmann, Guido
2014-01-01
Abstract Background: The partial pressure of oxygen (pO2) in blood samples can affect glucose measurements with oxygen-sensitive systems. In this study, we assessed the influence of different pO2 levels on blood glucose (BG) measurements with five glucose oxidase (GOD) systems and one glucose dehydrogenase (GDH) system. All selected GOD systems were indicated by the manufacturers to be sensitive to increased oxygen content of the blood sample. Materials and Methods: Venous blood samples of 16 subjects (eight women, eight men; mean age, 52 years; three with type 1 diabetes, four with type 2 diabetes, and nine without diabetes) were collected. Aliquots of each sample were adjusted to the following pO2 values: ≤45 mm Hg, approximately 70 mm Hg, and ≥150 mm Hg. For each system, five consecutive measurements on each sample were performed using the same test strip lot. Relative differences between the mean BG value at a pO2 level of approximately 70 mm Hg, which was considered to be similar to pO2 values in capillary blood samples, and the mean BG value at pO2 levels ≤45 mm Hg and ≥150 mm Hg were calculated. Results: The GOD systems showed mean relative differences between 11.8% and 44.5% at pO2 values ≤45 mm Hg and between −14.6% and −21.2% at pO2 values ≥150 mm Hg. For the GDH system, the mean relative differences were −0.3% and −0.2% at pO2 values ≤45 mm Hg and ≥150 mm Hg, respectively. Conclusions: The magnitude of the pO2 impact on BG measurements seems to vary among the tested oxygen-sensitive GOD systems. The pO2 range in which oxygen-sensitive systems operate well should be provided in the product information. PMID:24205977
2016-01-01
The objective of this study was to investigate the effects of partial beef fat replacement (0, 30, 50, 100%) with gelled emulsion (GE) prepared with olive oil on functional and quality properties of model system meat emulsion (MSME). GE consisted of inulin and gelatin as gelling agent and characteristics of gelled and model system meat emulsions were investigated. GE showed good initial stability against centrifugation forces and thermal stability at different temperatures. GE addition decreased the pH with respect to increase in GE concentration. Addition of GE increased lightness and yellowness but reduced redness compared to control samples. The results of the study showed that partial replacement of beef fat with GE could be used for improving cooking yield without negative effects on water holding capacity and emulsion stability compared to C samples when replacement level is up to 50%. The presence of GE significantly affected textural behaviors of samples (p<0.05). In conclusion, our study showed that GE have promising impacts on developing healthier meat product formulations besides improving technological characteristics. PMID:28115885
Serdaroğlu, Meltem; Nacak, Berker; Karabıyıkoğlu, Merve; Keser, Gökçen
2016-01-01
The objective of this study was to investigate the effects of partial beef fat replacement (0, 30, 50, 100%) with gelled emulsion (GE) prepared with olive oil on functional and quality properties of model system meat emulsion (MSME). GE consisted of inulin and gelatin as gelling agent and characteristics of gelled and model system meat emulsions were investigated. GE showed good initial stability against centrifugation forces and thermal stability at different temperatures. GE addition decreased the pH with respect to increase in GE concentration. Addition of GE increased lightness and yellowness but reduced redness compared to control samples. The results of the study showed that partial replacement of beef fat with GE could be used for improving cooking yield without negative effects on water holding capacity and emulsion stability compared to C samples when replacement level is up to 50%. The presence of GE significantly affected textural behaviors of samples ( p <0.05). In conclusion, our study showed that GE have promising impacts on developing healthier meat product formulations besides improving technological characteristics.
García-Molina, María Dolores; García-Olmo, Juan; Barro, Francisco
2016-01-01
Scope The aim of this work was to assess the ability of Near Infrared Spectroscopy (NIRS) to distinguish wheat lines with low gliadin content, obtained by RNA interference (RNAi), from non-transgenic wheat lines. The discriminant analysis was performed using both whole grain and flour. The transgenic sample set included 409 samples for whole grain sorting and 414 samples for flour experiments, while the non-transgenic set consisted of 126 and 156 samples for whole grain and flour, respectively. Methods and Results Samples were scanned using a Foss-NIR Systems 6500 System II instrument. Discrimination models were developed using the entire spectral range (400–2500 nm) and ranges of 400–780 nm, 800–1098 nm and 1100–2500 nm, followed by analysis of means of partial least square (PLS). Two external validations were made, using samples from the years 2013 and 2014 and a minimum of 99% of the flour samples and 96% of the whole grain samples were classified correctly. Conclusions The results demonstrate the ability of NIRS to successfully discriminate between wheat samples with low-gliadin content and wild types. These findings are important for the development and analysis of foodstuff for celiac disease (CD) patients to achieve better dietary composition and a reduction in disease incidence. PMID:27018786
Argon Collection And Purification For Proliferation Detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Achey, R.; Hunter, D.
2015-10-09
In order to determine whether a seismic event was a declared/undeclared underground nuclear weapon test, environmental samples must be taken and analyzed for signatures that are unique to a nuclear explosion. These signatures are either particles or gases. Particle samples are routinely taken and analyzed under the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) verification regime as well as by individual countries. Gas samples are analyzed for signature gases, especially radioactive xenon. Underground nuclear tests also produce radioactive argon, but that signature is not well monitored. A radioactive argon signature, along with other signatures, can more conclusively determine whether an event wasmore » a nuclear test. This project has developed capabilities for collecting and purifying argon samples for ultra-low-background proportional counting. SRNL has developed a continuous gas enrichment system that produces an output stream containing 97% argon from whole air using adsorbent separation technology (the flow diagram for the system is shown in the figure). The vacuum swing adsorption (VSA) enrichment system is easily scalable to produce ten liters or more of 97% argon within twelve hours. A gas chromatographic separation using a column of modified hydrogen mordenite molecular sieve has been developed that can further purify the sample to better than 99% purity after separation from the helium carrier gas. The combination of these concentration and purification systems has the capability of being used for a field-deployable system for collecting argon samples suitable for ultra-low-background proportional counting for detecting nuclear detonations under the On-Site Inspection program of the CTBTO verification regime. The technology also has applications for the bulk argon separation from air for industrial purposes such as the semi-conductor industry.« less
Comparison of a multispectral vision system and a colorimeter for the assessment of meat color.
Trinderup, Camilla H; Dahl, Anders; Jensen, Kirsten; Carstensen, Jens Michael; Conradsen, Knut
2015-04-01
The color assessment ability of a multispectral vision system is investigated by a comparison study with color measurements from a traditional colorimeter. The experiment involves fresh and processed meat samples. Meat is a complex material; heterogeneous with varying scattering and reflectance properties, so several factors can influence the instrumental assessment of meat color. In order to assess whether two methods are equivalent, the variation due to these factors must be taken into account. A statistical analysis was conducted and showed that on a calibration sheet the two instruments are equally capable of measuring color. Moreover the vision system provides a more color rich assessment of fresh meat samples with a glossier surface, than the colorimeter. Careful studies of the different sources of variation enable an assessment of the order of magnitude of the variability between methods accounting for other sources of variation leading to the conclusion that color assessment using a multispectral vision system is superior to traditional colorimeter assessments. Copyright © 2014 Elsevier Ltd. All rights reserved.
Uervirojnangkoorn, Monarin; Zeldin, Oliver B.; Lyubimov, Artem Y.; ...
2015-03-17
There is considerable potential for X-ray free electron lasers (XFELs) to enable determination of macromolecular crystal structures that are difficult to solve using current synchrotron sources. Prior XFEL studies often involved the collection of thousands to millions of diffraction images, in part due to limitations of data processing methods. We implemented a data processing system based on classical post-refinement techniques, adapted to specific properties of XFEL diffraction data. When applied to XFEL data from three different proteins collected using various sample delivery systems and XFEL beam parameters, our method improved the quality of the diffraction data as well as themore » resulting refined atomic models and electron density maps. Moreover, the number of observations for a reflection necessary to assemble an accurate data set could be reduced to a few observations. In conclusion, these developments will help expand the applicability of XFEL crystallography to challenging biological systems, including cases where sample is limited.« less
Literature-Related Discovery: Potential Treatments and Preventives for SARS
2010-01-01
evaluated the immunomodulatory effects of probiotic Bacillus cereus var. toyoi on the systemic immunity of piglets……Blood samples of probiotic ...and IFN-gamma production of polyclonally stimulated PBMCs was on average higher in the probiotic group. Specific proliferative responses of PBMCs...average higher in the probiotic group. In conclusion, B. cereus var. toyoi therefore alters the immune status of piglets as indicated by changes in
Laboratory Studies of Cometary Materials - Continuity Between Asteroid and Comet
NASA Technical Reports Server (NTRS)
Messenger, Scott; Walker, Robert M.
2015-01-01
Laboratory analysis of cometary samples have been enabled by collection of cometary dust in the stratosphere by high altitude aircraft and by the direct sampling of the comet Wild-2 coma by the NASA Stardust spacecraft. Cometary materials are composed of a complex assemblage of highly primitive, unprocessed interstellar and primordial solar system materials as well as a variety of high temperature phases that must have condensed in the inner regions of the protoplanetary disk. These findings support and contradict conclusions of comet properties based solely on astronomical observations. These sample return missions have instead shown that there is a continuity of properties between comets and asteroids, where both types of materials show evidence for primitive and processed materials. Furthermore, these findings underscore the importance and value of direct sample return. There will be great value in comparing the findings of the Stardust cometary coma sample return mission with those of future asteroid surface sample returns OSIRIS-REx and Hayabusa II as well as future comet nucleus sample returns.
NASA Technical Reports Server (NTRS)
James, John T.
2001-01-01
The toxicological assessment of air samples returned at the end of the STS-102 (5A.1) flight to the ISS is reported. ISS air samples were taken in late February 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges . A "first-entry" sample of the multipurpose logistics module (MPLM) atmosphere was taken with a GSC, and preflight and end-of-mission samples were obtained from Discovery using GSCs. Analytical methods have not changed from earlier reports, and all quality control measures were met for the data presented herein. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 contribution). Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols were also assessed in each sample. Formaldehyde is quantified separately.
Open-Source Automated Mapping Four-Point Probe.
Chandra, Handy; Allen, Spencer W; Oberloier, Shane W; Bihari, Nupur; Gwamuri, Jephias; Pearce, Joshua M
2017-01-26
Scientists have begun using self-replicating rapid prototyper (RepRap) 3-D printers to manufacture open source digital designs of scientific equipment. This approach is refined here to develop a novel instrument capable of performing automated large-area four-point probe measurements. The designs for conversion of a RepRap 3-D printer to a 2-D open source four-point probe (OS4PP) measurement device are detailed for the mechanical and electrical systems. Free and open source software and firmware are developed to operate the tool. The OS4PP was validated against a wide range of discrete resistors and indium tin oxide (ITO) samples of different thicknesses both pre- and post-annealing. The OS4PP was then compared to two commercial proprietary systems. Results of resistors from 10 to 1 MΩ show errors of less than 1% for the OS4PP. The 3-D mapping of sheet resistance of ITO samples successfully demonstrated the automated capability to measure non-uniformities in large-area samples. The results indicate that all measured values are within the same order of magnitude when compared to two proprietary measurement systems. In conclusion, the OS4PP system, which costs less than 70% of manual proprietary systems, is comparable electrically while offering automated 100 micron positional accuracy for measuring sheet resistance over larger areas.
2011-01-01
Background Previous research addressed the development of a classification scheme for quality improvement systems in European hospitals. In this study we explore associations between the 'maturity' of the hospitals' quality improvement system and clinical outcomes. Methods The maturity classification scheme was developed based on survey results from 389 hospitals in eight European countries. We matched the hospitals from the Spanish sample (113 hospitals) with those hospitals participating in a nation-wide, voluntary hospital performance initiative. We then compared sample distributions and explored associations between the 'maturity' of the hospitals' quality improvement system and a range of composite outcomes measures, such as adjusted hospital-wide mortality, -readmission, -complication and -length of stay indices. Statistical analysis includes bivariate correlations for parametrically and non-parametrically distributed data, multiple robust regression models and bootstrapping techniques to obtain confidence-intervals for the correlation and regression estimates. Results Overall, 43 hospitals were included. Compared to the original sample of 113, this sample was characterized by a higher representation of university hospitals. Maturity of the quality improvement system was similar, although the matched sample showed less variability. Analysis of associations between the quality improvement system and hospital-wide outcomes suggests significant correlations for the indicator adjusted hospital complications, borderline significance for adjusted hospital readmissions and non-significance for the adjusted hospital mortality and length of stay indicators. These results are confirmed by the bootstrap estimates of the robust regression model after adjusting for hospital characteristics. Conclusions We assessed associations between hospitals' quality improvement systems and clinical outcomes. From this data it seems that having a more developed quality improvement system is associated with lower rates of adjusted hospital complications. A number of methodological and logistic hurdles remain to link hospital quality improvement systems to outcomes. Further research should aim at identifying the latent dimensions of quality improvement systems that predict quality and safety outcomes. Such research would add pertinent knowledge regarding the implementation of organizational strategies related with quality of care outcomes. PMID:22185479
Bertrand-Krajewski, J L; Bardin, J P; Mourad, M; Béranger, Y
2003-01-01
Assessing the functioning and the performance of urban drainage systems on both rainfall event and yearly time scales is usually based on online measurements of flow rates and on samples of influent effluent for some rainfall events per year. In order to draw pertinent scientific and operational conclusions from the measurement results, it is absolutely necessary to use appropriate methods and techniques in order to i) calibrate sensors and analytical methods, ii) validate raw data, iii) evaluate measurement uncertainties, iv) evaluate the number of rainfall events to sample per year in order to determine performance indicator with a given uncertainty. Based an previous work, the paper gives a synthetic review of required and techniques, and illustrates their application to storage and settling tanks. Experiments show that, controlled and careful experimental conditions, relative uncertainties are about 20% for flow rates in sewer pipes, 6-10% for volumes, 25-35% for TSS concentrations and loads, and 18-276% for TSS removal rates. In order to evaluate the annual pollutant interception efficiency of storage and settling tanks with a given uncertainty, efforts should first be devoted to decrease the sampling uncertainty by increasing the number of sampled events.
2011-01-01
Background The aim of this study was to develop a child-specific classification system for long bone fractures and to examine its reliability and validity on the basis of a prospective multicentre study. Methods Using the sequentially developed classification system, three samples of between 30 and 185 paediatric limb fractures from a pool of 2308 fractures documented in two multicenter studies were analysed in a blinded fashion by eight orthopaedic surgeons, on a total of 5 occasions. Intra- and interobserver reliability and accuracy were calculated. Results The reliability improved with successive simplification of the classification. The final version resulted in an overall interobserver agreement of κ = 0.71 with no significant difference between experienced and less experienced raters. Conclusions In conclusion, the evaluation of the newly proposed classification system resulted in a reliable and routinely applicable system, for which training in its proper use may further improve the reliability. It can be recommended as a useful tool for clinical practice and offers the option for developing treatment recommendations and outcome predictions in the future. PMID:21548939
Thakar, Madhuri; Angira, Francis; Pattanapanyasat, Kovit; Wu, Alan H.B.; O’Gorman, Maurice; Zeng, Hui; Qu, Chenxue; Mahajan, Bharati; Sukapirom, Kasama; Chen, Danying; Hao, Yu; Gong, Yan; Indig, Monika De Arruda; Graminske, Sharon; Orta, Diana; d’Empaire, Nicole; Lu, Beverly; Omana-Zapata, Imelda; Zeh, Clement
2017-01-01
Background: The BD FACSPresto™ system uses capillary and venous blood to measure CD4 absolute counts (CD4), %CD4 in lymphocytes, and hemoglobin (Hb) in approximately 25 minutes. CD4 cell count is used with portable CD4 counters in resource-limited settings to manage HIV/AIDS patients. A method comparison was performed using capillary and venous samples from seven clinical laboratories in five countries. The BD FACSPresto system was assessed for variability between laboratory, instrument/operators, cartridge lots and within-run at four sites. Methods: Samples were collected under approved voluntary consent. EDTA-anticoagulated venous samples were tested for CD4 and %CD4 T cells using the gold-standard BD FACSCalibur™ system, and for Hb, using the Sysmex® KX-21N™ analyzer. Venous and capillary samples were tested on the BD FACSPresto system. Matched data was analyzed for bias (Deming linear regression and Bland-Altman methods), and for concordance around the clinical decision point. The coefficient of variation was estimated per site, instrument/operator, cartridge-lot and between-runs. Results: For method comparison, 93% of the 720 samples were from HIV-positive and 7% from HIV-negative or normal subjects. CD4 and %CD4 T cells venous and capillary results gave slopes within 0.96–1.05 and R2 ≥0.96; Hb slopes were ≥1.00 and R2 ≥0.89. Variability across sites/operators gave %CV <5.8% for CD4 counts, <1.9% for %CD4 and <3.2% for Hb. The total %CV was <7.7% across instrument/cartridge lot. Conclusion: The BD FACSPresto system provides accurate, reliable, precise CD4/%CD4/Hb results compared to gold-standard methods, irrespective of venous or capillary blood sampling. The data showed good agreement between the BD FACSPresto, BD FACSCalibur and Sysmex systems. PMID:29290885
Zheng, Xiasheng; Zhang, Peng; Liao, Baosheng; Li, Jing; Liu, Xingyun; Shi, Yuhua; Cheng, Jinle; Lai, Zhitian; Xu, Jiang; Chen, Shilin
2017-01-01
Herbal medicine is a major component of complementary and alternative medicine, contributing significantly to the health of many people and communities. Quality control of herbal medicine is crucial to ensure that it is safe and sound for use. Here, we investigated a comprehensive quality evaluation system for a classic herbal medicine, Danggui Buxue Formula, by applying genetic-based and analytical chemistry approaches to authenticate and evaluate the quality of its samples. For authenticity, we successfully applied two novel technologies, third-generation sequencing and PCR-DGGE (denaturing gradient gel electrophoresis), to analyze the ingredient composition of the tested samples. For quality evaluation, we used high performance liquid chromatography assays to determine the content of chemical markers to help estimate the dosage relationship between its two raw materials, plant roots of Huangqi and Danggui. A series of surveys were then conducted against several exogenous contaminations, aiming to further access the efficacy and safety of the samples. In conclusion, the quality evaluation system demonstrated here can potentially address the authenticity, quality, and safety of herbal medicines, thus providing novel insight for enhancing their overall quality control. Highlight: We established a comprehensive quality evaluation system for herbal medicine, by combining two genetic-based approaches third-generation sequencing and DGGE (denaturing gradient gel electrophoresis) with analytical chemistry approaches to achieve the authentication and quality connotation of the samples. PMID:28955365
Zheng, Xiasheng; Zhang, Peng; Liao, Baosheng; Li, Jing; Liu, Xingyun; Shi, Yuhua; Cheng, Jinle; Lai, Zhitian; Xu, Jiang; Chen, Shilin
2017-01-01
Herbal medicine is a major component of complementary and alternative medicine, contributing significantly to the health of many people and communities. Quality control of herbal medicine is crucial to ensure that it is safe and sound for use. Here, we investigated a comprehensive quality evaluation system for a classic herbal medicine, Danggui Buxue Formula, by applying genetic-based and analytical chemistry approaches to authenticate and evaluate the quality of its samples. For authenticity, we successfully applied two novel technologies, third-generation sequencing and PCR-DGGE (denaturing gradient gel electrophoresis), to analyze the ingredient composition of the tested samples. For quality evaluation, we used high performance liquid chromatography assays to determine the content of chemical markers to help estimate the dosage relationship between its two raw materials, plant roots of Huangqi and Danggui. A series of surveys were then conducted against several exogenous contaminations, aiming to further access the efficacy and safety of the samples. In conclusion, the quality evaluation system demonstrated here can potentially address the authenticity, quality, and safety of herbal medicines, thus providing novel insight for enhancing their overall quality control. Highlight : We established a comprehensive quality evaluation system for herbal medicine, by combining two genetic-based approaches third-generation sequencing and DGGE (denaturing gradient gel electrophoresis) with analytical chemistry approaches to achieve the authentication and quality connotation of the samples.
Özok, A.R.; Persoon, I.F.; Huse, S.M.; Keijser, B.J.F.; Wesselink, P.R.; Crielaard, W.; Zaura, E.
2016-01-01
Aim To evaluate the microbial ecology of the coronal and apical segments of infected root canal systems using a complete sampling technique and next-generation sequencing. Methodology The roots of 23 extracted teeth with apical periodontitis were sectioned in half, horizontally, and cryo-pulverized. Bacterial communities were profiled using tagged 454 pyrosequencing of the 16S rDNA hypervariable V5–V6 region. Results The sequences were classified into 606 taxa (species or higher taxon), representing 24 bacterial phyla or candidate divisions and one archaeal phylum. Proteobacteria were more abundant in the apical samples (p<0.05), while Actinobacteria were in significantly higher proportions in the coronal samples. The apical samples harbored statistically significantly more taxa than the coronal samples (p=0.01), and showed a higher microbial diversity. Several taxa belonging to fastidious obligate anaerobes were significantly more abundant in the apical segments of the roots compared to their coronal counterparts. Conclusions Endodontic infections are more complex than reported previously. The apical part of the root canal system drives the selection of a more diverse and more anaerobe community than the coronal part. The presence of a distinct ecological niche in the apical region explains the difficulty of eradication of the infection, and emphasizes the need that new treatment approaches should be developed. PMID:22251411
Improvement of immunoassay detection system by using alternating current magnetic susceptibility
NASA Astrophysics Data System (ADS)
Kawabata, R.; Mizoguchi, T.; Kandori, A.
2016-03-01
A major goal with this research was to develop a low-cost and highly sensitive immunoassay detection system by using alternating current (AC) magnetic susceptibility. We fabricated an improved prototype of our previously developed immunoassay detection system and evaluated its performance. The prototype continuously moved sample containers by using a magnetically shielded brushless motor, which passes between two anisotropic magneto resistance (AMR) sensors. These sensors detected the magnetic signal in the direction where each sample container passed them. We used the differential signal obtained from each AMR sensor's output to improve the signal-to-noise ratio (SNR) of the magnetic signal measurement. Biotin-conjugated polymer beads with avidin-coated magnetic particles were prepared to examine the calibration curve, which represents the relation between AC magnetic susceptibility change and polymer-bead concentration. For the calibration curve measurement, we, respectively, measured the magnetic signal caused by the magnetic particles by using each AMR sensor installed near the upper or lower part in the lateral position of the passing sample containers. As a result, the SNR of the prototype was 4.5 times better than that of our previous system. Moreover, the data obtained from each AMR sensor installed near the upper part in the lateral position of the passing sample containers exhibited an accurate calibration curve that represented good correlation between AC magnetic susceptibility change and polymer-bead concentration. The conclusion drawn from these findings is that our improved immunoassay detection system will enable a low-cost and highly sensitive immunoassay.
Improvement of immunoassay detection system by using alternating current magnetic susceptibility.
Kawabata, R; Mizoguchi, T; Kandori, A
2016-03-01
A major goal with this research was to develop a low-cost and highly sensitive immunoassay detection system by using alternating current (AC) magnetic susceptibility. We fabricated an improved prototype of our previously developed immunoassay detection system and evaluated its performance. The prototype continuously moved sample containers by using a magnetically shielded brushless motor, which passes between two anisotropic magneto resistance (AMR) sensors. These sensors detected the magnetic signal in the direction where each sample container passed them. We used the differential signal obtained from each AMR sensor's output to improve the signal-to-noise ratio (SNR) of the magnetic signal measurement. Biotin-conjugated polymer beads with avidin-coated magnetic particles were prepared to examine the calibration curve, which represents the relation between AC magnetic susceptibility change and polymer-bead concentration. For the calibration curve measurement, we, respectively, measured the magnetic signal caused by the magnetic particles by using each AMR sensor installed near the upper or lower part in the lateral position of the passing sample containers. As a result, the SNR of the prototype was 4.5 times better than that of our previous system. Moreover, the data obtained from each AMR sensor installed near the upper part in the lateral position of the passing sample containers exhibited an accurate calibration curve that represented good correlation between AC magnetic susceptibility change and polymer-bead concentration. The conclusion drawn from these findings is that our improved immunoassay detection system will enable a low-cost and highly sensitive immunoassay.
Imaging birefringent crystals using micro optical coherence tomography (Conference Presentation)
NASA Astrophysics Data System (ADS)
Sharma, Gargi; Singh, Kanwarpal; Gardecki, Joseph A.; Tearney, Guillermo J.
2017-02-01
Background: Uric acid crystals have recently been identified as a possible therapeutic target for coronary artery disease. Being subcellular in size, it is difficult to identify these crystals in situ. Micro optical coherence tomography (Micro-OCT) allows one to image subcellular structures with 1-micron resolution. Even though Micro-OCT should be capable of resolving urate crystals, it's difficult to differentiate these structures from other scattering particles within tissue. In this work we developed a novel polarization sensitive micro OCT (ps-Micro-OCT) system for identification of uric acid crystals. Methods: A spectrometer based ps-Micro-OCT system was developed using a broadband light source. The broadband input light was divided into reference and sample signals using a beam splitter. The reference signal was further divided into two polarized signals with different polarization states. Reflected reference and sample signals were combined and sent to a spectrometer that recorded the interference signal. Results: To test the performance of system, a mirror was used as sample and a quarter wave-plate was placed in the sample path. The measured quarter wave-plate angle values matched closely to actual angle values. Next we prepared uric acid crystals in our lab and imaged them using this system.We were able to image and identify these crystals based on polarization measurements. Conclusion: In this work we imaged and identified uric acid crystals using a newly developed ps-Micro-OCT system. The proposed technique will enable imaging uric acid crystals in coronary artery.
HIV-1 low copy viral sequencing-A prototype assay.
Mellberg, Tomas; Krabbe, Jon; Gisslén, Magnus; Svennerholm, Bo
2016-01-01
In HIV-1 patients with low viral burden, sequencing is often problematic, yet important. This study presents a sensitive, sub-type independent system for sequencing of low level viremia. Sequencing data from 32 HIV-1 infected patients with low level viremia were collected longitudinally. A combination of ViroSeq® HIV-1 Genotyping System and an in-house nesting protocol was used. Eight sub-types were represented. The success-rate of amplification of both PR and RT in the same sample was 100% in samples with viral loads above 100 copies/ml. Below 100 copies/ml, this study managed to amplify both regions in 7/13 (54%) samples. The assays were able to amplify either PR or RT in all sub-types included but one sub-type A specimen. In conclusion, this study presents a promising, simple assay to increase the ability to perform HIV-1 resistance testing at low level viremia. This is a prototype assay and the method needs further testing to evaluate clinical performance.
Application of Magnetic Nanoparticles in Pretreatment Device for POPs Analysis in Water
NASA Astrophysics Data System (ADS)
Chu, Dongzhi; Kong, Xiangfeng; Wu, Bingwei; Fan, Pingping; Cao, Xuan; Zhang, Ting
2018-01-01
In order to reduce process time and labour force of POPs pretreatment, and solve the problem that extraction column was easily clogged, the paper proposed a new technology of extraction and enrichment which used magnetic nanoparticles. Automatic pretreatment system had automatic sampling unit, extraction enrichment unit and elution enrichment unit. The paper briefly introduced the preparation technology of magnetic nanoparticles, and detailly introduced the structure and control system of automatic pretreatment system. The result of magnetic nanoparticles mass recovery experiments showed that the system had POPs analysis preprocessing capability, and the recovery rate of magnetic nanoparticles were over 70%. In conclusion, the author proposed three points optimization recommendation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lorenz, Matthias; Ovchinnikova, Olga S; Van Berkel, Gary J
RATIONALE: Laser ablation provides for the possibility of sampling a large variety of surfaces with high spatial resolution. This type of sampling when employed in conjunction with liquid capture followed by nanoelectrospray ionization provides the opportunity for sensitive and prolonged interrogation of samples by mass spectrometry as well as the ability to analyze surfaces not amenable to direct liquid extraction. METHODS: A fully automated, reflection geometry, laser ablation liquid capture spot sampling system was achieved by incorporating appropriate laser fiber optics and a focusing lens into a commercially available, liquid extraction surface analysis (LESA ) ready Advion TriVersa NanoMate system.more » RESULTS: Under optimized conditions about 10% of laser ablated material could be captured in a droplet positioned vertically over the ablation region using the NanoMate robot controlled pipette. The sampling spot size area with this laser ablation liquid capture surface analysis (LA/LCSA) mode of operation (typically about 120 m x 160 m) was approximately 50 times smaller than that achievable by direct liquid extraction using LESA (ca. 1 mm diameter liquid extraction spot). The set-up was successfully applied for the analysis of ink on glass and paper as well as the endogenous components in Alstroemeria Yellow King flower petals. In a second mode of operation with a comparable sampling spot size, termed laser ablation/LESA , the laser system was used to drill through, penetrate, or otherwise expose material beneath a solvent resistant surface. Once drilled, LESA was effective in sampling soluble material exposed at that location on the surface. CONCLUSIONS: Incorporating the capability for different laser ablation liquid capture spot sampling modes of operation into a LESA ready Advion TriVersa NanoMate enhanced the spot sampling spatial resolution of this device and broadened the surface types amenable to analysis to include absorbent and solvent resistant materials.« less
Bhagwat, Swarupa Nikhil; Sharma, Jayashree H; Jose, Julie; Modi, Charusmita J
2015-01-01
Context: The routine immunohematological tests can be performed by automated as well as manual techniques. These techniques have advantages and disadvantages inherent to them. Aims: The present study aims to compare the results of manual and automated techniques for blood grouping and crossmatching so as to validate the automated system effectively. Materials and Methods: A total of 1000 samples were subjected to blood grouping by the conventional tube technique (CTT) and the automated microplate LYRA system on Techno TwinStation. A total of 269 samples (multitransfused patients and multigravida females) were compared for 927 crossmatches by the CTT in indirect antiglobulin phase against the column agglutination technique (CAT) performed on Techno TwinStation. Results: For blood grouping, the study showed a concordance in results for 942/1000 samples (94.2%), discordance for 4/1000 (0.4%) samples and uninterpretable result for 54/1000 samples (5.4%). On resolution, the uninterpretable results reduced to 49/1000 samples (4.9%) with 951/1000 samples (95.1%) showing concordant results. For crossmatching, the automated CAT showed concordant results in 887/927 (95.6%) and discordant results in 3/927 (0.32%) crossmatches as compared to the CTT. Total 37/927 (3.9%) crossmatches were not interpretable by the automated technique. Conclusions: The automated system shows a high concordance of results with CTT and hence can be brought into routine use. However, the high proportion of uninterpretable results emphasizes on the fact that proper training and standardization are needed prior to its use. PMID:26417159
2000-04-01
system, 8 - experiments on a study of boundary layer spectrum infrared window). before boiling of glass- silicide coating. This simple 3. SAMPLES AND...dependencies of surface temperature of tested materials and make conclusions concerned joint gllass- silicide coating and anode power of generator...obtained using test stagnation point configuration. glass- silicide coating vs anode power of HF-generator. Temperature peak at constant power
Importance sampling with imperfect cloning for the computation of generalized Lyapunov exponents
NASA Astrophysics Data System (ADS)
Anteneodo, Celia; Camargo, Sabrina; Vallejos, Raúl O.
2017-12-01
We revisit the numerical calculation of generalized Lyapunov exponents, L (q ) , in deterministic dynamical systems. The standard method consists of adding noise to the dynamics in order to use importance sampling algorithms. Then L (q ) is obtained by taking the limit noise-amplitude → 0 after the calculation. We focus on a particular method that involves periodic cloning and pruning of a set of trajectories. However, instead of considering a noisy dynamics, we implement an imperfect (noisy) cloning. This alternative method is compared with the standard one and, when possible, with analytical results. As a workbench we use the asymmetric tent map, the standard map, and a system of coupled symplectic maps. The general conclusion of this study is that the imperfect-cloning method performs as well as the standard one, with the advantage of preserving the deterministic dynamics.
Monsanto, Stephany P.; Edwards, Andrew K.; Zhou, Juhua; Nagarkatti, Prakash; Nagarkatti, Mitzi; Young, Steven L.; Lessey, Bruce A.; Tayade, Chandrakant
2016-01-01
Objective To determine the impact of endometriotic lesion removal on local and systemic inflammation. Design Multiplex cytokine analysis on samples from endometriosis patients before surgery, 2 weeks after surgery, and 3 months after surgery. Setting Academic teaching hospital and university. Patient(s) A total of 43 endometriosis patients before and after excision of lesions by means of laparoscopic surgery, and 25 normal women. Intervention(s) None. Main Outcome Measure(s) Plasma, eutopic and ectopic tissue, and peritoneal fluid cytokine levels. Result(s) Compared with presurgery plasma samples, levels of granulocyte-macrophage colony-stimulating factor (GM-CSF), interleukin (IL) 2, IL-8, and IL-10 decreased significantly by 2 weeks after surgery in endometriosis patients. Interestingly, levels began to rise at 3 months after surgery in most cases. In tissue, levels of GM-CSF and IL-15 were lower in eutopic tissue, while levels of basic fibroblast growth factor, interferon-inducible protein 10, IL-1 receptor antagonist, granulocyte colony–stimulating factor, macrophage inflammatory protein 1β, IL-7, and IL-5 were higher in eutopic than in ectopic tissue. In peritoneal fluid, levels of IL-5 and IL-12 were higher in early versus advanced stages of endometriosis. Compared with normal women, plasma from endometriosis patients had higher levels of inflammatory cytokines. Conclusion(s) Endometriotic lesion removal significantly alters the inflammatory profile both locally and systemically in women with endometriosis. Our findings indicate that ectopic lesions are the major drivers of systemic inflammation in endometriosis. The transitory nature of the change may reflect the recurrence of the condition and the influence of systemic factors in its onset. PMID:26698677
2014-01-01
Background Gait analysis and research have been developed to obtain characteristics of movement patterns of people while walking. However, traditional measuring systems present different drawbacks that reduce their use and application. Among those drawbacks one can find: high price, low sampling frequency and limiting number of steps to be analyzed. Traditional measuring gait systems carry out their measurement at frequencies oscillating between 60 to 100 Hz. It can be argued about the need of higher sampling rates for gait measurements. However small displacements of the knee or hip for example, cannot be seen with low frequencies required a more detailed sampling and higher frequency sampling. Bearing this in mind, in this paper is presented a 250 Hz system based on accelerometers for gait measurement, and the particularities of knee and hip angles during gait are highlighted. Methods The system was designed with a PCI data acquisition card instrumented with an FPGA to achieve a rate sample of 250 Hz. The accelerometers were placed in thighs and legs to calculate the joint angles of hip and knee in the sagittal plane. The angles were estimated using the acceleration polygon method without integrating the acceleration and without filters. Results The gait of thirty healthy people of Mexican phenotype was analyzed over a flat floor free of obstacles. The results showed the gait phases and particularities associated with the walking style and people's laterality; the movement patterns were similar in the thirty persons. Based on the results, the particularities as the maximum amplitude in the angles and the shape in the movement patterns were related to the anthropometry and people phenotype. Conclusions The sampling frequency was essential to record 340 samples in single gait cycle and so registering the gait cycle with its particularities. In this work were recorded an average of 8 to 10 gait cycles, and the results showed variation regarding works carried out in biomechanics laboratories; this variation was related to the method and reference frame used to obtain the joint angles and the accuracy of measurement system. PMID:24684720
Fischer, Jochen; Brinkmann, Detert; Elsinghorst, Paul W; Wüst, Matthias
2012-07-01
A novel SIDA-DI-SPME-GC/MS procedure for the quantitation of skatole in pork meat juice was developed and validated as a substitute for back fat sample analysis. System suitability was evaluated by determining the correlation between skatole concentrations in a subset of 38 paired meat juice and back fat samples selected from 90 fattened boars. High correlation was observed between both matrices and conclusions about the partitioning of skatole as well as of androstenone between fat and lean compartments in vivo were drawn. Copyright © 2012 Elsevier Ltd. All rights reserved.
Human blood RNA stabilization in samples collected and transported for a large biobank
2012-01-01
Background The Norwegian Mother and Child Cohort Study (MoBa) is a nation-wide population-based pregnancy cohort initiated in 1999, comprising more than 108.000 pregnancies recruited between 1999 and 2008. In this study we evaluated the feasibility of integrating RNA analyses into existing MoBa protocols. We compared two different blood RNA collection tube systems – the PAXgene™ Blood RNA system and the Tempus™ Blood RNA system - and assessed the effects of suboptimal blood volumes in collection tubes and of transportation of blood samples by standard mail. Endpoints to characterize the samples were RNA quality and yield, and the RNA transcript stability of selected genes. Findings High-quality RNA could be extracted from blood samples stabilized with both PAXgene and Tempus tubes. The RNA yields obtained from the blood samples collected in Tempus tubes were consistently higher than from PAXgene tubes. Higher RNA yields were obtained from cord blood (3 – 4 times) compared to adult blood with both types of tubes. Transportation of samples by standard mail had moderate effects on RNA quality and RNA transcript stability; the overall RNA quality of the transported samples was high. Some unexplained changes in gene expression were noted, which seemed to correlate with suboptimal blood volumes collected in the tubes. Temperature variations during transportation may also be of some importance. Conclusions Our results strongly suggest that special collection tubes are necessary for RNA stabilization and they should be used for establishing new biobanks. We also show that the 50,000 samples collected in the MoBa biobank provide RNA of high quality and in sufficient amounts to allow gene expression analyses for studying the association of disease with altered patterns of gene expression. PMID:22988904
Lynn Hedt, Bethany; van Leth, Frank; Zignol, Matteo; Cobelens, Frank; van Gemert, Wayne; Viet Nhung, Nguyen; Lyepshina, Svitlana; Egwaga, Saidi; Cohen, Ted
2012-01-01
Background Current methodology for multidrug-resistant TB (MDR TB) surveys endorsed by the World Health Organization provides estimates of MDR TB prevalence among new cases at the national level. On the aggregate, local variation in the burden of MDR TB may be masked. This paper investigates the utility of applying lot quality-assurance sampling to identify geographic heterogeneity in the proportion of new cases with multidrug resistance. Methods We simulated the performance of lot quality-assurance sampling by applying these classification-based approaches to data collected in the most recent TB drug-resistance surveys in Ukraine, Vietnam, and Tanzania. We explored three classification systems—two-way static, three-way static, and three-way truncated sequential sampling—at two sets of thresholds: low MDR TB = 2%, high MDR TB = 10%, and low MDR TB = 5%, high MDR TB = 20%. Results The lot quality-assurance sampling systems identified local variability in the prevalence of multidrug resistance in both high-resistance (Ukraine) and low-resistance settings (Vietnam). In Tanzania, prevalence was uniformly low, and the lot quality-assurance sampling approach did not reveal variability. The three-way classification systems provide additional information, but sample sizes may not be obtainable in some settings. New rapid drug-sensitivity testing methods may allow truncated sequential sampling designs and early stopping within static designs, producing even greater efficiency gains. Conclusions Lot quality-assurance sampling study designs may offer an efficient approach for collecting critical information on local variability in the burden of multidrug-resistant TB. Before this methodology is adopted, programs must determine appropriate classification thresholds, the most useful classification system, and appropriate weighting if unbiased national estimates are also desired. PMID:22249242
NASA Astrophysics Data System (ADS)
Calderone, G. M.
2006-12-01
A long-term monitoring program was initiated in 1995 at 6 sites at NAS Brunswick, including 3 National Priorities List (Superfund) sites. Primary contaminants of concern include chlorinated volatile organic compounds, including tetrachloroethane, trichloroethene, and vinyl chloride, in addition to metals. More than 80 submersible pumping systems were installed to facilitate sample collection utilizing the low-flow sampling technique. Long-term monitoring of the groundwater is conducted to assess the effectiveness of remedial measures, and monitor changes in contaminant concentrations in the Eastern Plume Operable Unit. Long-term monitoring program activities include quarterly groundwater sampling and analysis at more than 90 wells across 6 sites; surface water, sediment, seep, and leachate sampling and analysis at 3 sites; landfill gas monitoring; well maintenance; engineering inspections of landfill covers and other sites or evidence of stressed vegetation; water level gauging; and treatment plant sampling and analysis. Significant cost savings were achieved by optimizing the sampling network and reducing sampling frequency from quarterly to semi- annual or annual sampling. As part of an ongoing optimization effort, a geostatistical assessment of the Eastern Plume was conducted at the Naval Air Station, Brunswick, Maine. The geostatistical assessment used 40 monitoring points and analytical data collected over 3 years. For this geostatistical assessment, EA developed and utilized a database of analytical results generated during 3 years of long-term monitoring which was linked to a Geographic Information System to enhance data visualization capacity. The Geographic Information System included themes for groundwater volatile organic compound concentration, groundwater flow directions, shallow and deep wells, and immediate access to point-specific analytical results. This statistical analysis has been used by the site decision-maker and its conclusions supported a significant reduction in the Long-Term Monitoring Program.
Near-infrared spectroscopy (NIRS) as a tool to monitor exhaust air from poultry operations.
Druckenmüller, Katharina; Günther, Klaus; Elbers, Gereon
2018-07-15
Intensive poultry operation systems emit a considerable volume of inorganic and organic matter in the surrounding environment. Monitoring cleaning properties of exhaust air cleaning systems and to detect small but significant changes in emission characteristics during a fattening cycle is important for both emission and fattening process control. In the present study, we evaluated the potential of near-infrared spectroscopy (NIRS) combined with chemometric techniques as a monitoring tool of exhaust air from poultry operation systems. To generate a high-quality data set for evaluation, the exhaust air of two poultry houses was sampled by applying state-of-the-art filter sampling protocols. The two stables were identical except for one crucial difference, the presence or absence of an exhaust air cleaning system. In total, twenty-one exhaust air samples were collected at the two sites to monitor spectral differences caused by the cleaning device, and to follow changes in exhaust air characteristics during a fattening period. The total dust load was analyzed by gravimetric determination and included as a response variable in multivariate data analysis. The filter samples were directly measured with NIR spectroscopy. Principal component analysis (PCA), linear discriminant analysis (LDA), and factor analysis (FA) were effective in classifying the NIR exhaust air spectra according to fattening day and origin. The results indicate that the dust load and the composition of exhaust air (inorganic or organic matter) substantially influence the NIR spectral patterns. In conclusion, NIR spectroscopy as a tool is a promising and very rapid way to detect differences between exhaust air samples based on still not clearly defined circumstances triggered during a fattening period and the availability of an exhaust air cleaning system. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Houssaini, Allal; Assoumou, Lambert; Miller, Veronica; Calvez, Vincent; Marcelin, Anne-Geneviève; Flandre, Philippe
2013-01-01
Background Several attempts have been made to determine HIV-1 resistance from genotype resistance testing. We compare scoring methods for building weighted genotyping scores and commonly used systems to determine whether the virus of a HIV-infected patient is resistant. Methods and Principal Findings Three statistical methods (linear discriminant analysis, support vector machine and logistic regression) are used to determine the weight of mutations involved in HIV resistance. We compared these weighted scores with known interpretation systems (ANRS, REGA and Stanford HIV-db) to classify patients as resistant or not. Our methodology is illustrated on the Forum for Collaborative HIV Research didanosine database (N = 1453). The database was divided into four samples according to the country of enrolment (France, USA/Canada, Italy and Spain/UK/Switzerland). The total sample and the four country-based samples allow external validation (one sample is used to estimate a score and the other samples are used to validate it). We used the observed precision to compare the performance of newly derived scores with other interpretation systems. Our results show that newly derived scores performed better than or similar to existing interpretation systems, even with external validation sets. No difference was found between the three methods investigated. Our analysis identified four new mutations associated with didanosine resistance: D123S, Q207K, H208Y and K223Q. Conclusions We explored the potential of three statistical methods to construct weighted scores for didanosine resistance. Our proposed scores performed at least as well as already existing interpretation systems and previously unrecognized didanosine-resistance associated mutations were identified. This approach could be used for building scores of genotypic resistance to other antiretroviral drugs. PMID:23555613
The SAMPL4 host-guest blind prediction challenge: an overview.
Muddana, Hari S; Fenley, Andrew T; Mobley, David L; Gilson, Michael K
2014-04-01
Prospective validation of methods for computing binding affinities can help assess their predictive power and thus set reasonable expectations for their performance in drug design applications. Supramolecular host-guest systems are excellent model systems for testing such affinity prediction methods, because their small size and limited conformational flexibility, relative to proteins, allows higher throughput and better numerical convergence. The SAMPL4 prediction challenge therefore included a series of host-guest systems, based on two hosts, cucurbit[7]uril and octa-acid. Binding affinities in aqueous solution were measured experimentally for a total of 23 guest molecules. Participants submitted 35 sets of computational predictions for these host-guest systems, based on methods ranging from simple docking, to extensive free energy simulations, to quantum mechanical calculations. Over half of the predictions provided better correlations with experiment than two simple null models, but most methods underperformed the null models in terms of root mean squared error and linear regression slope. Interestingly, the overall performance across all SAMPL4 submissions was similar to that for the prior SAMPL3 host-guest challenge, although the experimentalists took steps to simplify the current challenge. While some methods performed fairly consistently across both hosts, no single approach emerged as consistent top performer, and the nonsystematic nature of the various submissions made it impossible to draw definitive conclusions regarding the best choices of energy models or sampling algorithms. Salt effects emerged as an issue in the calculation of absolute binding affinities of cucurbit[7]uril-guest systems, but were not expected to affect the relative affinities significantly. Useful directions for future rounds of the challenge might involve encouraging participants to carry out some calculations that replicate each others' studies, and to systematically explore parameter options.
Perera, Rushini S.; Ding, Xavier C.; Tully, Frank; Oliver, James; Bright, Nigel; Bell, David; Chiodini, Peter L.; Gonzalez, Iveth J.; Polley, Spencer D.
2017-01-01
Background Accurate and efficient detection of sub-microscopic malaria infections is crucial for enabling rapid treatment and interruption of transmission. Commercially available malaria LAMP kits have excellent diagnostic performance, though throughput is limited by the need to prepare samples individually. Here, we evaluate the clinical performance of a newly developed high throughput (HTP) sample processing system for use in conjunction with the Eiken malaria LAMP kit. Methods The HTP system utilised dried blood spots (DBS) and liquid whole blood (WB), with parallel sample processing of 94 samples per run. The system was evaluated using 699 samples of known infection status pre-determined by gold standard nested PCR. Results The sensitivity and specificity of WB-HTP-LAMP was 98.6% (95% CI, 95.7–100), and 99.7% (95% CI, 99.2–100); sensitivity of DBS-HTP-LAMP was 97.1% (95% CI, 93.1–100), and specificity 100% against PCR. At parasite densities greater or equal to 2 parasites/μL, WB and DBS HTP-LAMP showed 100% sensitivity and specificity against PCR. At densities less than 2 p/μL, WB-HTP-LAMP sensitivity was 88.9% (95% CI, 77.1–100) and specificity was 99.7% (95% CI, 99.2–100); sensitivity and specificity of DBS-HTP-LAMP was 77.8% (95% CI, 54.3–99.5) and 100% respectively. Conclusions The HTP-LAMP system is a highly sensitive diagnostic test, with the potential to allow large scale population screening in malaria elimination campaigns. PMID:28166235
Van Berkel, Gary J.; Kertesz, Vilmos
2016-11-15
An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized themore » spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Berkel, Gary J.; Kertesz, Vilmos
An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized themore » spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.« less
One-dimensional ion-beam figuring for grazing-incidence reflective optics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Lin; Idir, Mourad; Bouet, Nathalie
2016-01-01
One-dimensional ion-beam figuring (1D-IBF) can improve grazing-incidence reflective optics, such as Kirkpatrick–Baez mirrors. 1D-IBF requires only one motion degree of freedom, which reduces equipment complexity, resulting in compact and low-cost IBF instrumentation. Furthermore, 1D-IBF is easy to integrate into a single vacuum system with other fabrication processes, such as a thin-film deposition. The NSLS-II Optical Metrology and Fabrication Group has recently integrated the 1D-IBF function into an existing thin-film deposition system by adding an RF ion source to the system. Using a rectangular grid, a 1D removal function needed to perform 1D-IBF has been produced. In this paper, demonstration experimentsmore » of the 1D-IBF process are presented on one spherical and two plane samples. The final residual errors on both plane samples are less than 1 nm r.m.s. In conclusion, the surface error on the spherical sample has been successfully reduced by a factor of 12. The results show that the 1D-IBF method is an effective method to process high-precision 1D synchrotron optics.« less
Van Berkel, Gary J.; Kertesz, Vilmos
2015-08-25
RATIONALE: A simple method to introduce unprocessed samples into a solvent for rapid characterization by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The continuous flow, self-cleaning open port sampling interface introduced here fills this void. METHODS: The open port sampling interface used a vertically aligned, co-axial tube arrangement enabling solvent delivery to the sampling end of the device through the tubing annulus and solvent aspiration down the center tube and into the mass spectrometer ionization source via the commercial APCI emitter probe. The solvent delivery rate to the interface was set to exceed the aspiration rate creatingmore » a continuous sampling interface along with a constant, self-cleaning spillover of solvent from the top of the probe. RESULTS: Using the open port sampling interface with positive ion mode APCI and a hybrid quadrupole time of flight mass spectrometer, rapid, direct sampling and analysis possibilities are exemplified with plastics, ballpoint and felt tip ink pens, skin, and vegetable oils. These results demonstrated that the open port sampling interface could be used as a simple, versatile and self-cleaning system to rapidly introduce multiple types of unprocessed, sometimes highly concentrated and complex, samples into a solvent flow stream for subsequent ionization and analysis by mass spectrometry. The basic setup presented here could be incorporated with any self-aspirating liquid introduction ionization source (e.g., ESI, APCI, APPI, ICP, etc.) or any type of atmospheric pressure sampling ready mass spectrometer system. CONCLUSIONS: The open port sampling interface provides a means to introduce and quickly analyze unprocessed solid or liquid samples with liquid introduction atmospheric pressure ionization source without fear of sampling interface or ionization source contamination.« less
Lasić, Lejla; Lojo-Kadrić, Naida; Silajdžić, Elma; Pojskić, Lejla; Hadžiselimović, Rifat; Pojskić, Naris
2013-01-01
There are two major theories for inheritance of Rh blood group system: Fisher – Race theory and Wiener theory. Aim of this study was identifying frequency of RHDCE alleles in Bosnian – Herzegovinian population and introduction of this method in screening for Rh phenotype in B&H since this type of analysis was not used for blood typing in B&H before. Rh blood group was typed by Polymerase Chain Reaction, using the protocols and primers previously established by other authors, then carrying out electrophoresis in 2-3% agarose gel. Percentage of Rh positive individuals in our sample is 84.48%, while the percentage of Rh negative individuals is 15.52%. Inter-rater agreement statistic showed perfect agreement (K=1) between the results of Rh blood system detection based on serological and molecular-genetics methods. In conclusion, molecular – genetic methods are suitable for prenatal genotyping and specific cases while standard serological method is suitable for high-throughput of samples. PMID:23448604
Lefkowitz, Daniel; Pechter, Elise; Fitzsimmons, Kathleen; Lumia, Margaret; Stephens, Alicia C.; Davis, Letitia; Flattery, Jennifer; Weinberg, Justine; Harrison, Robert J.; Reilly, Mary Jo; Filios, Margaret S.; White, Gretchen E.; Rosenman, Kenneth D.
2015-01-01
Background Isocyanates remain a leading cause of work-related asthma (WRA). Methods Two independent data systems were analyzed for the period 1993–2008: (1) State-based WRA case surveillance data on persons with isocyanate-induced WRA from four states, and (2) Occupational Safety and Health Administration (OSHA) Integrated Management Information System (IMIS) isocyanate air sampling results. Results We identified 368 cases of isocyanate-induced WRA from 32 industries and 678 OSHA isocyanate air samples with detectable levels from 31 industries. Seventeen industries were unique to one or the other dataset. Conclusion Isocyanate-induced WRA continues to occur in a wide variety of industries. Two data systems uncovered industries with isocyanate exposures and/or illness. Improved control measures and standards, including medical surveillance, are needed. More emphasis is needed on task-specific guidance, spill clean-up procedures, skin and respiratory protection, and targeted medical monitoring to mitigate the hazards of isocyanate use. PMID:26351141
Environmental Measurement-While-Drilling system for real-time field screening of contaminants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lockwood, G.J.; Normann, R.A.; Bishop, L.B.
Sampling during environmental drilling is essential to fully characterize the spatial distribution and migration of near surface contaminants. However, the analysis of these samples is not only expensive, but can take weeks or months when sent to an off-site laboratory. In contrast, measurement-while-drilling (MWD) screening capability could save money and valuable time by quickly distinguishing between contaminated and uncontaminated areas. Real-time measurements provided by a MVM system would enable on-the-spot decisions to be made regarding sampling strategies, enhance worker safety, and provide the added flexibility of being able to ``steer`` the drill bit in or out hazardous zones. During measurement-while-drilling,more » down-hole sensors are located behind the drill bit and linked by a rapid data transmission system to a computer at the surface. As drilling proceeds, data are collected on the nature and extent of the subsurface contamination in real-time. The down-hole sensor is a Geiger-Mueller tube (GMT) gamma radiation detector. In addition to the GMT signal, the MWD system monitors these required down-hole voltages and two temperatures associated with the detector assembly. The Gamma Ray Detection System (GRDS) and electronics package are discussed in as well as the results of the field test. Finally, our conclusions and discussion of future work are presented.« less
Open-Source Automated Mapping Four-Point Probe
Chandra, Handy; Allen, Spencer W.; Oberloier, Shane W.; Bihari, Nupur; Gwamuri, Jephias; Pearce, Joshua M.
2017-01-01
Scientists have begun using self-replicating rapid prototyper (RepRap) 3-D printers to manufacture open source digital designs of scientific equipment. This approach is refined here to develop a novel instrument capable of performing automated large-area four-point probe measurements. The designs for conversion of a RepRap 3-D printer to a 2-D open source four-point probe (OS4PP) measurement device are detailed for the mechanical and electrical systems. Free and open source software and firmware are developed to operate the tool. The OS4PP was validated against a wide range of discrete resistors and indium tin oxide (ITO) samples of different thicknesses both pre- and post-annealing. The OS4PP was then compared to two commercial proprietary systems. Results of resistors from 10 to 1 MΩ show errors of less than 1% for the OS4PP. The 3-D mapping of sheet resistance of ITO samples successfully demonstrated the automated capability to measure non-uniformities in large-area samples. The results indicate that all measured values are within the same order of magnitude when compared to two proprietary measurement systems. In conclusion, the OS4PP system, which costs less than 70% of manual proprietary systems, is comparable electrically while offering automated 100 micron positional accuracy for measuring sheet resistance over larger areas. PMID:28772471
Rain Erosion Studies of Sapphire, Aluminum Oxynitride, Spinel, Lanthana- Doped Yttria, and TAF Glass
1990-07-01
small , there is little change in average scatter for any material in any test. CONCLUSIONS AND DISCUSSION The principal conclusions are 1. ALON...20 Sample broke erosion damage 10 Slight pitting, 20 No change erosion damage 15 Pitting, cratering, 20 Small surface pits erosion damage 15 Pitting...Sample broke 10 No damage 15 Sample pitted, small edge fracture 15 Slight pitting, 1 crater, 20 Sample pitted, erosion damage small edge fracture 15 SUght
2009-01-01
Background In the global eradication program for poliomyelitis, the laboratory diagnosis plays a critical role by isolating poliovirus (PV) from the stool samples of acute flaccid paralysis (AFP) cases. In this study, we developed a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) system for a rapid and highly sensitive detection of enterovirus including PV to identify stool samples positive for enterovirus including PV. Methods A primer set was designed for RT-LAMP to detect enterovirus preferably those with PV-like 5'NTRs of the viral genome. The sensitivity of RT-LAMP system was evaluated with prototype strains of enterovirus. Detection of enterovirus from stool extracts was examined by using RT-LAMP system. Results We detected at least 400 copies of the viral genomes of PV(Sabin) strains within 90 min by RT-LAMP with the primer set. This RT-LAMP system showed a preference for Human enterovirus species C (HEV-C) strains including PV, but exhibited less sensitivity to the prototype strains of HEV-A and HEV-B (detection limits of 7,400 to 28,000 copies). Stool extracts, from which PV, HEV-C, or HEV-A was isolated in the cell culture system, were mostly positive by RT-LAMP method (positive rates of 15/16 (= 94%), 13/14 (= 93%), and 4/4 (= 100%), respectively). The positive rate of this RT-LAMP system for stool extracts from which HEV-B was isolated was lower than that of HEV-C (positive rate of 11/21 (= 52%)). In the stool samples, which were negative for enterovirus isolation by the cell culture system, we found that two samples were positive for RT-LAMP (positive rates of 2/38 (= 5.3%)). In these samples, enterovirus 96 was identified by sequence analysis utilizing a seminested PCR system. Conclusions RT-LAMP system developed in this study showed a high sensitivity comparable to that of the cell culture system for the detection of PV, HEV-A, and HEV-C, but less sensitivity to HEV-B. This RT-LAMP system would be useful for the direct detection of enterovirus from the stool extracts. PMID:20015403
2010-03-23
Micron 41 (2010) 615–621 619 Fig. 4 . XPS binding energy (eV) versus sputtering time (s) results for the Ti 2p peaks for the titanium samples: (a...improved the IQ values. 4 . Conclusions The electrochemical–mechanical polishing system (ECMP) removed material from titanium and nickel alloys at a...March 2014 4 . TITLE AND SUBTITLE NOVEL AUTOMATIC ELECTROCHEMICAL-MECHANICAL POLISHING (ECMP) OF METALS FOR SCANNING ELECTRON MICROSCOPY
Camposampiero, D; Grandesso, S; Zanetti, E; Mazzucato, S; Solinas, M; Parekh, M; Frigo, A C; Gion, M; Ponzin, D
2013-01-01
Aims. To compare HB&L and BACTEC systems for detecting the microorganisms contaminating the corneal storage liquid preserved at 31°C. Methods. Human donor corneas were stored at 4°C followed by preservation at 31°C. Samples of the storage medium were inoculated in BACTEC Peds Plus/F (aerobic microorganisms), BACTEC Plus Anaerobic/F (anaerobic microorganisms), and HB&L bottles. The tests were performed (a) after six days of storage, (b) end of storage, and (c) after 24 hours of preservation in deturgescent liquid sequentially. 10,655 storage and deturgescent media samples were subjected to microbiological control using BACTEC (6-day incubation) and HB&L (24-hour incubation) systems simultaneously. BACTEC positive/negative refers to both/either aerobic and anaerobic positives/negatives, whereas HB&L can only detect the aerobic microbes, and therefore the positives/negatives depend on the presence/absence of aerobic microorganisms. Results. 147 (1.38%) samples were identified positive with at least one of the two methods. 127 samples (134 identified microorganisms) were positive with both HB&L and BACTEC. 14 HB&L+/BACTEC- and 6 BACTEC+/HB&L- were identified. Sensitivity (95.5%), specificity (99.8%), and positive (90.1%) and negative predictive values (99.9%) were high with HB&L considering a 3.5% annual contamination rate. Conclusion. HB&L is a rapid system for detecting microorganisms in corneal storage medium in addition to the existing methods.
Yu, Songlin; Cheng, Xinqi; Fang, Huiling; Zhang, Ruiping; Han, Jianhua; Qin, Xuzhen; Cheng, Qian; Su, Wei; Hou, Li’an; Xia, Liangyu; Qiu, Ling
2015-01-01
Variations in vitamin D quantification methods are large, and influences of vitamin D analogues and blood collection methods have not been systematically examined. We evaluated the effects of vitamin D analogues 25OHD2 and 3-epi 25OHD3 and blood collection methods on vitamin D measurement, using five immunoassay systems and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Serum samples (332) were selected from routine vitamin D assay requests, including samples with or without 25OHD2 or 3-epi 25OHD3, and analysed using various immunoassay systems. In samples with no 25OHD2 or 3-epi 25OHD3, all immunoassays correlated well with LC-MS/MS. However, the Siemens system produced a large positive mean bias of 12.5 ng/mL and a poor Kappa value when using tubes with clot activator and gel separator. When 25OHD2 or 3-epi 25OHD3 was present, correlations and clinical agreement decreased for all immunoassays. Serum 25OHD in VACUETTE tubes with gel and clot activator, as measured by the Siemens system, produced significantly higher values than did samples collected in VACUETTE tubes with no additives. Bias decreased and clinical agreement improved significantly when using tubes with no additives. In conclusion, most automated immunoassays showed acceptable correlation and agreement with LC-MS/MS; however, 25OHD analogues and blood collection tubes dramatically affected accuracy. PMID:26420221
Yu, Songlin; Cheng, Xinqi; Fang, Huiling; Zhang, Ruiping; Han, Jianhua; Qin, Xuzhen; Cheng, Qian; Su, Wei; Hou, Li'an; Xia, Liangyu; Qiu, Ling
2015-09-30
Variations in vitamin D quantification methods are large, and influences of vitamin D analogues and blood collection methods have not been systematically examined. We evaluated the effects of vitamin D analogues 25OHD2 and 3-epi 25OHD3 and blood collection methods on vitamin D measurement, using five immunoassay systems and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Serum samples (332) were selected from routine vitamin D assay requests, including samples with or without 25OHD2 or 3-epi 25OHD3, and analysed using various immunoassay systems. In samples with no 25OHD2 or 3-epi 25OHD3, all immunoassays correlated well with LC-MS/MS. However, the Siemens system produced a large positive mean bias of 12.5 ng/mL and a poor Kappa value when using tubes with clot activator and gel separator. When 25OHD2 or 3-epi 25OHD3 was present, correlations and clinical agreement decreased for all immunoassays. Serum 25OHD in VACUETTE tubes with gel and clot activator, as measured by the Siemens system, produced significantly higher values than did samples collected in VACUETTE tubes with no additives. Bias decreased and clinical agreement improved significantly when using tubes with no additives. In conclusion, most automated immunoassays showed acceptable correlation and agreement with LC-MS/MS; however, 25OHD analogues and blood collection tubes dramatically affected accuracy.
Sampling characteristics of satellite orbits
NASA Technical Reports Server (NTRS)
Wunsch, Carl
1989-01-01
The irregular space-time sampling of any finite region by an orbiting satellite raises difficult questions as to which frequencies and wavenumbers can be determined and which will alias into others. Conventional sampling theorems must be extended to account for both irregular data distributions and observational noise - the sampling irregularity making the system much more susceptible to noise than in regularly sampled cases. The problem is formulated here in terms of least-squares and applied to spacecraft in 10-day and 17-day repeating orbits. The 'diamond-pattern' laid down spatially in such repeating orbits means that either repeat period adequately samples the spatial variables, but the slow overall temporal coverage in the 17-day pattern leads to much greater uncertainty than in the shorter repeat cycle. The result is not definitive and it is not concluded that a 10-day orbit repeat is the most appropriate one. A major conclusion, however, is that different orbital choices have potentially quite different sampling characteristics which need to be analyzed in terms of the spectral characteristics of the moving sea surface.
Mehrtak, Mohamad; Vatankhah, Soodabeh; Delgoshaei, Bahram; Gholipour, Arian
2014-01-01
Background: Succession planning promotes the culture of private ownership, staff loyalty to the organization and develops organizational commitment, and increases organizational stability. The study was conducted to examine the status of succession planning in the Iranian health system in order to highlight the key concepts, provide new insight, and attract the attention of senior managers of the Ministry of Health and Medical Education to the importance of succession planning in achieving organizational goals. Methods: In a qualitative study with a framework analysis approach, semi-structured interviews were conducted with a sample selected using purposive and snowball sampling procedure. The MAXQDA-10 was used to apply the codes and manage the data. The codes were extracted using inductive and deductive methods. Results: Fourteen themes and six main subthemes were identified, including planning, organizational culture, system approach, competency model, career path, and senior managers. Our findings indicate a lack of succession planning in the Iranian health system. Conclusion: lack of succession planning could lead to inefficiency and ineffectiveness in health services provision. Implementation of succession planning could maximize human resources utilization. PMID:25168998
Massively Parallel Sequencing of Forensic STRs Using the Ion Chef™ and the Ion S5™ XL Systems.
Wang, Le; Chen, Man; Wu, Bo; Liu, Yi-Cheng; Zhang, Guang-Feng; Jiang, Li; Xu, Xiu-Lan; Zhao, Xing-Chun; Ji, An-Quan; Ye, Jian
2018-03-01
Next-generation sequencing (NGS) has been used to genotype forensic short tandem repeat (STR) markers for individual identification and kinship analysis. STR data from several NGS platforms have been published, but forensic application trials using the Ion S5™ XL system have not been reported. In this work, we report sensitivity, reproducibility, mixture, simulated degradation, and casework sample data on the Ion Chef™ and S5™ XL systems using an early access 25-plex panel. Sensitivity experiments showed that over 97% of the alleles were detectable with down to 62 pg input of genomic DNA. In mixture studies, alleles from minor contributors were correctly assigned at 1:9 and 9:1 ratios. NGS successfully gave 12 full genotype results from 13 challenging casework samples, compared with five full results using the CE platform. In conclusion, the Ion Chef™ and the Ion S5™ XL systems provided an alternative and promising approach for forensic STR genotyping. © 2018 American Academy of Forensic Sciences.
Garty, Guy; Chen, Youhua; Turner, Helen; Zhang, Jian; Lyulko, Oleksandra; Bertucci, Antonella; Xu, Yanping; Wang, Hongliang; Simaan, Nabil; Randers-Pehrson, Gerhard; Yao, Y. Lawrence; Brenner, David J.
2011-01-01
Purpose Over the past five years the Center for Minimally Invasive Radiation Biodosimetry at Columbia University has developed the Rapid Automated Biodosimetry Tool (RABiT), a completely automated, ultra-high throughput biodosimetry workstation. This paper describes recent upgrades and reliability testing of the RABiT. Materials and methods The RABiT analyzes fingerstick-derived blood samples to estimate past radiation exposure or to identify individuals exposed above or below a cutoff dose. Through automated robotics, lymphocytes are extracted from fingerstick blood samples into filter-bottomed multi-well plates. Depending on the time since exposure, the RABiT scores either micronuclei or phosphorylation of the histone H2AX, in an automated robotic system, using filter-bottomed multi-well plates. Following lymphocyte culturing, fixation and staining, the filter bottoms are removed from the multi-well plates and sealed prior to automated high-speed imaging. Image analysis is performed online using dedicated image processing hardware. Both the sealed filters and the images are archived. Results We have developed a new robotic system for lymphocyte processing, making use of an upgraded laser power and parallel processing of four capillaries at once. This system has allowed acceleration of lymphocyte isolation, the main bottleneck of the RABiT operation, from 12 to 2 sec/sample. Reliability tests have been performed on all robotic subsystems. Conclusions Parallel handling of multiple samples through the use of dedicated, purpose-built, robotics and high speed imaging allows analysis of up to 30,000 samples per day. PMID:21557703
Sarapas, Casey; Katz, Andrea C; Nelson, Brady D; Campbell, Miranda L; Bishop, Jeffrey R; Robison-Andrew, E Jenna; Altman, Sarah E; Gorka, Stephanie M; Shankman, Stewart A
2014-01-01
Appetitive and defensive motivation account for a good deal of variance in personality and mental health, but whether individual differences in these systems are correlated or orthogonal has not been conclusively established. Previous investigations have generally relied on self-report and have yielded conflicting results. We therefore assessed the relation between psychophysiological indices of appetitive and defensive motivation during elicitation of these motivational states: specifically, frontal electroencephalogram asymmetry during reward anticipation and startle response during anticipation of predictable or unpredictable threat of shock. Results in a sample of psychopathology-free community members (n=63), an independent sample of undergraduates with a range of internalising symptoms (n=64), and the combination of these samples (n=127) revealed that differences in responding to the two tasks were not significantly correlated. Average coefficients approached zero in all three samples (community: .04, undergraduate: -.01, combined: .06). Implications of these findings for research on normal and abnormal personality are discussed.
NASA Astrophysics Data System (ADS)
Wang, Sheng; Wang, Linshan; Wei, Tengda
2018-04-01
This paper concerns the dynamics of a stochastic predator-prey system with Markovian switching and Lévy noise. First, the existence and uniqueness of global positive solution to the system is proved. Then, by combining stochastic analytical techniques with M-matrix analysis, sufficient conditions of stochastic permanence and extinction are obtained. Furthermore, for the stochastic permanence case, by means of four constants related to the stationary probability distribution of the Markov chain and the parameters of the subsystems, both the superior limit and the inferior limit of the average in time of the sample path of the solution are estimated. Finally, our conclusions are illustrated through an example.
Nonlinear Dynamics of a Foil Bearing Supported Rotor System: Simulation and Analysis
NASA Technical Reports Server (NTRS)
Li, Feng; Flowers, George T.
1996-01-01
Foil bearings provide noncontacting rotor support through a number of thin metal strips attached around the circumference of a stator and separated from the rotor by a fluid film. The resulting support stiffness is dominated by the characteristics of the foils and is a nonlinear function of the rotor deflection. The present study is concerned with characterizing this nonlinear effect and investigating its influence on rotordynamical behavior. A finite element model is developed for an existing bearing, the force versus deflection relation characterized, and the dynamics of a sample rotor system are studied. Some conclusions are discussed with regard to appropriate ranges of operation for such a system.
Pineda, Gina M; Montgomery, Anne H; Thompson, Robyn; Indest, Brooke; Carroll, Marion; Sinha, Sudhir K
2014-11-01
There is a constant need in forensic casework laboratories for an improved way to increase the first-pass success rate of forensic samples. The recent advances in mini STR analysis, SNP, and Alu marker systems have now made it possible to analyze highly compromised samples, yet few tools are available that can simultaneously provide an assessment of quantity, inhibition, and degradation in a sample prior to genotyping. Currently there are several different approaches used for fluorescence-based quantification assays which provide a measure of quantity and inhibition. However, a system which can also assess the extent of degradation in a forensic sample will be a useful tool for DNA analysts. Possessing this information prior to genotyping will allow an analyst to more informatively make downstream decisions for the successful typing of a forensic sample without unnecessarily consuming DNA extract. Real-time PCR provides a reliable method for determining the amount and quality of amplifiable DNA in a biological sample. Alu are Short Interspersed Elements (SINE), approximately 300bp insertions which are distributed throughout the human genome in large copy number. The use of an internal primer to amplify a segment of an Alu element allows for human specificity as well as high sensitivity when compared to a single copy target. The advantage of an Alu system is the presence of a large number (>1000) of fixed insertions in every human genome, which minimizes the individual specific variation possible when using a multi-copy target quantification system. This study utilizes two independent retrotransposon genomic targets to obtain quantification of an 80bp "short" DNA fragment and a 207bp "long" DNA fragment in a degraded DNA sample in the multiplex system InnoQuant™. The ratio of the two quantitation values provides a "Degradation Index", or a qualitative measure of a sample's extent of degradation. The Degradation Index was found to be predictive of the observed loss of STR markers and alleles as degradation increases. Use of a synthetic target as an internal positive control (IPC) provides an additional assessment for the presence of PCR inhibitors in the test sample. In conclusion, a DNA based qualitative/quantitative/inhibition assessment system that accurately predicts the status of a biological sample, will be a valuable tool for deciding which DNA test kit to utilize and how much target DNA to use, when processing compromised forensic samples for DNA testing. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bond, C.A.; Mignerey, A.C.; Helz, G.R.
The recent conclusion of a study of groundwater from the Magothy Formation, Maryland allows for an examination of processes occurring in this aquifer system. Water samples were gathered from a wide area along flow paths estimated from hydrological parameters and analyzed for the major cations and anions, nutrients, and {sup 87}Sr/{sup 86}Sr ratios, in addition to {sup 36}Cl, {delta}{sup 18}O, and {delta}{sup 2}H. Also, three samples that contained anomalously high {sup 36}Cl/Cl ratios were analyzed for {sup 3}H in an attempt to determine possible sources for those readings. A comparison of the results of this study to those of amore » previous study conducted by this group of the overlying Aquia Aquifer will also be given. The potential of inter-aquifer mixing between the two systems in some areas and of matching {sup 36}Cl and Cl{sup -} values to sea level rise and fall will be discussed.« less
A novel experimental system of high stability and lifetime for the laser-desorption of biomolecules.
Taherkhani, Mehran; Riese, Mikko; BenYezzar, Mohammed; Müller-Dethlefs, Klaus
2010-06-01
A novel laser desorption system, with improved signal stability and extraordinary long lifetime, is presented for the study of jet-cooled biomolecules in the gas phase using vibrationally resolved photoionization spectroscopy. As a test substance tryptophane is used to characterize this desorption source. A usable lifetime of above 1 month (for a laser desorption repetition rate of 20 Hz) has been observed by optimizing the pellets (graphite/tryptophane, 3 mm diameter and 6 mm length) from which the substance is laser-desorbed. Additionally, the stability and signal-to-noise ratio has been improved by averaging the signal over the entire sample pellet by synchronizing the data acquisition with the rotation of the sample rod. The results demonstrate how a combination of the above helps to produce stable and conclusive spectra of tryptophane using one-color and two-color resonant two-photon ionization studies.
Search for Primitive Matter in the Solar System
NASA Technical Reports Server (NTRS)
Libourel, G.; Michel, P.; Delbo, M.; Ganino, C.; Recio-Blanco, A.; de Laverny, P.; Zolensky, M. E.; Krot, A. N.
2017-01-01
Recent astronomical observations and theoretical modeling led to a consensus regarding the global scenario of the formation of young stellar objects (YSO) from a cold molecular cloud of interstellar dust (organics and minerals) and gas that, in some cases, leads to the formation of a planetary system. In the case of our Solar System, which has already evolved for approximately 4567 Ma, the quest is to access, through the investigation of planets, moons, cometary and asteroidal bodies, meteorites, micrometeorites, and interplanetary dust particles, the primitive material that contains the key information about the early Solar System processes and its evolution. However, laboratory analyses of extraterrestrial samples, astronomical observations and dynamical models of the Solar System evolution have not brought yet any conclusive evidence on the nature and location of primitive matter in the Solar System, preventing a clear understanding of its early stages.
Sample entropy analysis of cervical neoplasia gene-expression signatures
Botting, Shaleen K; Trzeciakowski, Jerome P; Benoit, Michelle F; Salama, Salama A; Diaz-Arrastia, Concepcion R
2009-01-01
Background We introduce Approximate Entropy as a mathematical method of analysis for microarray data. Approximate entropy is applied here as a method to classify the complex gene expression patterns resultant of a clinical sample set. Since Entropy is a measure of disorder in a system, we believe that by choosing genes which display minimum entropy in normal controls and maximum entropy in the cancerous sample set we will be able to distinguish those genes which display the greatest variability in the cancerous set. Here we describe a method of utilizing Approximate Sample Entropy (ApSE) analysis to identify genes of interest with the highest probability of producing an accurate, predictive, classification model from our data set. Results In the development of a diagnostic gene-expression profile for cervical intraepithelial neoplasia (CIN) and squamous cell carcinoma of the cervix, we identified 208 genes which are unchanging in all normal tissue samples, yet exhibit a random pattern indicative of the genetic instability and heterogeneity of malignant cells. This may be measured in terms of the ApSE when compared to normal tissue. We have validated 10 of these genes on 10 Normal and 20 cancer and CIN3 samples. We report that the predictive value of the sample entropy calculation for these 10 genes of interest is promising (75% sensitivity, 80% specificity for prediction of cervical cancer over CIN3). Conclusion The success of the Approximate Sample Entropy approach in discerning alterations in complexity from biological system with such relatively small sample set, and extracting biologically relevant genes of interest hold great promise. PMID:19232110
Hazardous Gas Leak Analysis in the Space Shuttle
NASA Technical Reports Server (NTRS)
Barile, Ronald G.
1991-01-01
Helium tests of the main propulsion system in the Space Shuttle and on hydrogen leaks are examined. The hazardous gas detection system (HGDS) in the mobile launch pad uses mass spectrometers (MS) to monitor the shuttle environment for leaks. The mass spectrometers are fed by long tubes to sample gas from the payload bay, mid-body, aft engine compartment, and external tank. The purpose is to improve the HGDS, especially in its potential for locating cryogen leaks. Pre-existing leak data was analyzed for transient information to determine if the leak location could be pinpointed from test data. A rapid response leak detection experiment was designed, built, and tested. Large eddies and vortices were visually seen with Schlieren imaging, and they were detected in the time plots of the various instruments. The response time of the MS was found in the range of 0.05 to 0.1 sec. Pulsed concentration waves were clearly detected at 25 cycles per sec by spectral analysis of MS data. One conclusion is that the backup HGDS sampling frequency should be increased above the present rate of 1 sample per second.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ringbom, Anders; Elmgren, K.; Lindh, Karin
Abstract Following the claimed nuclear test in the Democratic People’s Republic of Korea (DPRK) on October 9, 2006, and a reported seismic event, a mobile system for sampling of atmospheric xenon was transported to the Republic of South Korea (ROK) in an attempt to detect possible emissions of radioxenon in the region from a presumed test. Five samples were collected in the ROK during October 11–14, 2006 near the ROK–DPRK border, and thereafter transported to the Swedish Defense Research Agency (FOI) in Stockholm, Sweden, for analysis. Following the initial measurements, an automatic radioxenon sampling and analysis system was installed atmore » the same location in the ROK, and measurements on the ambient atmospheric radioxenon background in the region were performed during November 2006 to February 2007. The measured radioxenon concentrations strongly indicate that the explosion in October 9, 2006 was a nuclear test. The conclusion is further strengthened by atmospheric transport models. Radioactive xenon measurement was the only independent confirmation that the supposed test was in fact a nuclear explosion and not a conventional (chemical) explosive.« less
Optimization of wireless Bluetooth sensor systems.
Lonnblad, J; Castano, J; Ekstrom, M; Linden, M; Backlund, Y
2004-01-01
Within this study, three different Bluetooth sensor systems, replacing cables for transmission of biomedical sensor data, have been designed and evaluated. The three sensor architectures are built on 1-, 2- and 3-chip solutions and depending on the monitoring situation and signal character, different solutions are optimal. Essential parameters for all systems have been low physical weight and small size, resistance to interference and interoperability with other technologies as global- or local networks, PC's and mobile phones. Two different biomedical input signals, ECG and PPG (photoplethysmography), have been used to evaluate the three solutions. The study shows that it is possibly to continuously transmit an analogue signal. At low sampling rates and slowly varying parameters, as monitoring the heart rate with PPG, the 1-chip solution is the most suitable, offering low power consumption and thus a longer battery lifetime or a smaller battery, minimizing the weight of the sensor system. On the other hand, when a higher sampling rate is required, as an ECG, the 3-chip architecture, with a FPGA or micro-controller, offers the best solution and performance. Our conclusion is that Bluetooth might be useful in replacing cables of medical monitoring systems.
Malignant Tumors and Forensics – Dilemmas and Proposals
Budimlija, Zoran; Lu, Connie; Axler-DiPerte, Grace; Seifarth, Jessica; Popiolek, Dorota; Fogt, Franz; Prinz, Mechthild
2009-01-01
Aim To evaluate the effect of genetic instability and degradation in archived histology samples from cancerous tumors and to investigate the validity of short tandem repeat (STR) typing of these samples and its potential effect on human identification. Methods Two hundred and twenty eight slides of archival pathology tissues from 13 different types of malignant tumors were compared with healthy tissues from the same individuals. DNA analysis was performed using standard techniques for forensic STR analysis, PowerPlex®16 and Identifiler® on 2 distinct sample sets. Genetic instability was assessed by comparing reference tissues with cancerous tissues derived from the same individual. Loss of heterozygosity, a ≥50% reduction in heterozygosity ratio between healthy and diseased samples, and microsatellite instability, the presence of an additional allele not present in reference tissue, were assessed. The quality of profiles obtained with respect to completeness among the archived samples and degradation using the 2 platforms were also compared. Results Profiles obtained using the Identifiler® system were generally more complete, but showed 3-fold higher levels of instability (86%) than those obtained using PowerPlex® 16 (27%). Instances of genetic instability were distributed throughout all loci in both multiplex STR systems. Conclusion After having compared 2 widely used forensic chemistries, we suggest individual validation of each kit for use with samples likely to exhibit instability combined with fixation induced degradation or artifact. A “one size fits all” approach for interpretation of these samples among commercially available multiplexes is not recommended. PMID:19480018
Wildt, Signe; Krag, Aleksander; Gluud, Liselotte
2011-01-01
Objectives To evaluate the adequacy of reporting of protocols for randomised trials on diseases of the digestive system registered in http://ClinicalTrials.gov and the consistency between primary outcomes, secondary outcomes and sample size specified in http://ClinicalTrials.gov and published trials. Methods Randomised phase III trials on adult patients with gastrointestinal diseases registered before January 2009 in http://ClinicalTrials.gov were eligible for inclusion. From http://ClinicalTrials.gov all data elements in the database required by the International Committee of Medical Journal Editors (ICMJE) member journals were extracted. The subsequent publications for registered trials were identified. For published trials, data concerning publication date, primary and secondary endpoint, sample size, and whether the journal adhered to ICMJE principles were extracted. Differences between primary and secondary outcomes, sample size and sample size calculations data in http://ClinicalTrials.gov and in the published paper were registered. Results 105 trials were evaluated. 66 trials (63%) were published. 30% of trials were registered incorrectly after their completion date. Several data elements of the required ICMJE data list were not filled in, with missing data in 22% and 11%, respectively, of cases concerning the primary outcome measure and sample size. In 26% of the published papers, data on sample size calculations were missing and discrepancies between sample size reporting in http://ClinicalTrials.gov and published trials existed. Conclusion The quality of registration of randomised controlled trials still needs improvement.
How Do Cracks Initiate and Grow in a Thin Glass Plate? A Peridynamic Analysis
2014-06-17
evolution of these cracks, and confirm these results with fractography experiments of post-mortem samples. The results provide evidence of the predictive...face Questions to be answered Can we understand how and why each type of crack system forms? Crack surface fractography can give indication of...Symmetrical cracks form on the lower-right quarter of the plate. Jared Wright (ARL) fractography results Conclusions • The simplest peridynamic model
ISS Potable Water Sampling and Chemical Analysis Results for 2016
NASA Technical Reports Server (NTRS)
Straub, John E., II; Plumlee, Debrah K.; Wallace William T.; Alverson, James T.; Benoit, Mickie J.; Gillispie, Robert L.; Hunter, David; Kuo, Mike; Rutz, Jeffrey A.; Hudson, Edgar K.;
2017-01-01
This paper continues the annual tradition of summarizing at this conference the results of chemical analyses performed on archival potable water samples returned from the International Space Station (ISS). 2016 represented a banner year for life on board the ISS, including the successful conclusion for two crew members of a record one-year mission. Water reclaimed from urine and/or humidity condensate remained the primary source of potable water for the crew members of ISS Expeditions 46-50. The year 2016 was also marked by the end of a long-standing tradition of U.S. sampling and monitoring of Russian Segment potable water sources. Two water samples taken during Expedition 46 in February 2016 and returned on Soyuz 44, represented the final Russian Segment samples to be collected and analyzed by the U.S. side. Although anticipated for 2016, a rise in the total organic carbon (TOC) concentration of the product water from the U.S. water processor assembly due to breakthrough of organic contaminants from the system did not materialize, as evidenced by the onboard TOC analyzer and archive sample results.
ISS Potable Water Sampling and Chemical Analysis Results for 2016
NASA Technical Reports Server (NTRS)
Straub, John E., II; Plumlee, Debrah K.; Wallace, William T.; Alverson, James T.; Benoit, Mickie J.; Gillispie, Robert L.; Hunter, David; Kuo, Mike; Rutz, Jeffrey A.; Hudson, Edgar K.;
2017-01-01
This paper continues the annual tradition, at this conference, of summarizing the results of chemical analyses performed on archival potable water samples returned from the International Space Station (ISS). 2016 represented a banner year for life aboard the ISS, including the successful conclusion for 2 crewmembers of a record 1-year mission. Water reclaimed from urine and/or humidity condensate remained the primary source of potable water for the crewmembers of ISS Expeditions 46-50. The year was also marked by the end of a long-standing tradition of U.S. sampling and monitoring of Russian Segment potable water sources. Two water samples, taken during Expedition 46 and returned on Soyuz 44 in March 2016, represented the final Russian Segment samples to be collected and analyzed by the U.S. side. Although anticipated for 2016, a rise in the total organic carbon (TOC) concentration of the product water from the U.S. water processor assembly due to breakthrough of organic contaminants from the system did not materialize, as evidenced by the onboard TOC analyzer and archival sample results.
Improved system for floor cleaning in health care facilities.
Schmidt, E A; Coleman, D L; Mallison, G F
1984-01-01
A new system has been developed for sanitizing floors in hospitals; this system replaces the traditional procedure of daily dusting and wet mopping with a disinfectant-detergent solution and periodic buffing . This new system relies on a sequence of procedures consisting of dust mopping using a chemically treated dust mop, machine buffing of a sprayed-on polymer treatment, and a second dust mopping . The effectiveness of the procedures was evaluated by means of surface sampling for bacterial contamination and air sampling for airborne bacteria and dust. The level of bacterial contamination on the floors was reduced by 93.6% by using the new system, compared with 79.8% by using the conventional process of dust mopping and wet mopping with a disinfectant solution. The levels of airborne bacteria during and after the individual procedures did not vary significantly from the initial level (123.6 CFU/per m3 of air). A survey of representative colonies from air samples revealed staphylococci, gram-positive bacilli, gram-positive diplococci, yeast cells, and infrequent gram-negative rods. The distribution at the conclusion of the sanitizing process was similar to that at the outset. Similarly, the levels of airborne dust measured during and after the individual procedures did not vary significantly from the initial level. When compared with the traditional method of cleaning by wet mopping , the new method was significantly more effective in removal of microbial contamination and required less labor. PMID:6742835
Systemic effect of mineral aggregate-based cements: histopathological analysis in rats
Garcia, Lucas da Fonseca Roberti; Huck, Claudia; Magalhães, Fernando Augusto Cintra; de Souza, Pedro Paulo Chaves; de Souza Costa, Carlos Alberto
2017-01-01
Abstract Objective: Several studies reported the local tissue reaction caused by mineral aggregate-based cements. However, few studies have investigated the systemic effects promoted by these cements on liver and kidney when directly applied to connective tissue. The purpose of this in vivo study was to investigate the systemic effect of mineral aggregate-based cements on the livers and kidneys of rats. Material and Methods: Samples of Mineral Trioxide Aggregate (MTA) and a calcium aluminate-based cement (EndoBinder) containing different radiopacifiers were implanted into the dorsum of 40 rats. After 7 and 30 d, samples of subcutaneous, liver and kidney tissues were submitted to histopathological analysis. A score (0-3) was used to grade the inflammatory reaction. Blood samples were collected to evaluate changes in hepatic and renal functions of animals. Results: The moderate inflammatory reaction (2) observed for 7 d in the subcutaneous tissue decreased with time for all cements. The thickness of inflammatory capsules also presented a significant decrease with time (P<.05). Systemically, all cements caused adverse inflammatory reactions in the liver and kidney, being more evident for MTA, persisting until the end of the analysis. Liver functions increased significantly for MTA during 30 d (P<.05). Conclusion: The different cements induced to a locally limited inflammatory reaction. However, from the systemic point of view, the cements promoted significant inflammatory reactions in the liver and kidney. For MTA, the reactions were more accentuated. PMID:29211283
Calmette, Leyla; Ibrahim, Firas; Gouin, Isabelle; Horellou, Marie-Hélène; Mazoyer, Élisabeth; Fontenay, Michaela; Flaujac, Claire
2017-02-01
Samples transported by pneumatic tube system are submitted to forces of acceleration and deceleration which can affect laboratory parameters. At Cochin hospital, majority of samples of hemostasis, except for platelets tests, are transported by pneumatic tube system. The objective of this study was to evaluate the impact of a pneumatic tube system (PTS) transport compared to hand-delivered transport on samples and to qualify Cochin hospital PTS according to requirements of standard ISO 15189. A bibliographical study was made and showed that pneumatic tube system particularly influences platelets tests. Four citrate tubes were collected in 5 healthy volunteers in the maternity: 2 tubes were transported by PTS and 2 others were hand-delivered to the laboratory. Five coagulation tests were analyzed: prothrombine time (PT), activated partial thromboplastin time (aPTT), factor (F) V, FVIII and platelet closure time with PFA-100TM collagen/epinephrine. For each volunteer, the results obtained by PTS and by hand-delivered transport were compared with formula usually used for biological analysis retake: 2.8 x standard deviation of reproductibility variation coefficient (SH GTA 01, COFRAC). This study did not show an impact of PTS on PT, aPTT, FV and FVIII. For PFA-100TM collagen/epinephrine, we noted an impact on 2/5 volunteers. These results, in agreement with the literature, led to the conclusion that Cochin hospital PTS is in compliance to transport samples for usual coagulation tests except platelet tests. This study allowed to issue French recommendations for PTS transport of hemostasis tubes qualification available on "Groupe français d'hémostase et thrombose" Web site.
Jeddi, Fatemeh Rangraz; Farzandipoor, Mehrdad; Arabfard, Masoud; Hosseini, Azam Haj Mohammad
2016-01-01
Objective: The purpose of this study was investigating situation and presenting a conceptual model for clinical governance information system by using UML in two sample hospitals. Background: However, use of information is one of the fundamental components of clinical governance; but unfortunately, it does not pay much attention to information management. Material and Methods: A cross sectional study was conducted in October 2012- May 2013. Data were gathered through questionnaires and interviews in two sample hospitals. Face and content validity of the questionnaire has been confirmed by experts. Data were collected from a pilot hospital and reforms were carried out and Final questionnaire was prepared. Data were analyzed by descriptive statistics and SPSS 16 software. Results: With the scenario derived from questionnaires, UML diagrams are presented by using Rational Rose 7 software. The results showed that 32.14 percent Indicators of the hospitals were calculated. Database was not designed and 100 percent of the hospital’s clinical governance was required to create a database. Conclusion: Clinical governance unit of hospitals to perform its mission, do not have access to all the needed indicators. Defining of Processes and drawing of models and creating of database are essential for designing of information systems. PMID:27147804
Jeddi, Fatemeh Rangraz; Farzandipoor, Mehrdad; Arabfard, Masoud; Hosseini, Azam Haj Mohammad
2014-01-01
Objective: The purpose of this study was investigating situation and presenting a conceptual model for clinical governance information system by using UML in two sample hospitals. Background: However, use of information is one of the fundamental components of clinical governance; but unfortunately, it does not pay much attention to information management. Material and Methods: A cross sectional study was conducted in October 2012- May 2013. Data were gathered through questionnaires and interviews in two sample hospitals. Face and content validity of the questionnaire has been confirmed by experts. Data were collected from a pilot hospital and reforms were carried out and Final questionnaire was prepared. Data were analyzed by descriptive statistics and SPSS 16 software. Results: With the scenario derived from questionnaires, UML diagrams are presented by using Rational Rose 7 software. The results showed that 32.14 percent Indicators of the hospitals were calculated. Database was not designed and 100 percent of the hospital’s clinical governance was required to create a database. Conclusion: Clinical governance unit of hospitals to perform its mission, do not have access to all the needed indicators. Defining of Processes and drawing of models and creating of database are essential for designing of information systems. PMID:24825933
Impact of Implementation of an Automated Liquid Culture System on Diagnosis of Tuberculous Pleurisy.
Lee, Byung Hee; Yoon, Seong Hoon; Yeo, Hye Ju; Kim, Dong Wan; Lee, Seung Eun; Cho, Woo Hyun; Lee, Su Jin; Kim, Yun Seong; Jeon, Doosoo
2015-07-01
This study was conducted to evaluate the impact of implementation of an automated liquid culture system on the diagnosis of tuberculous pleurisy in an HIV-uninfected patient population. We retrospectively compared the culture yield, time to positivity, and contamination rate of pleural effusion samples in the BACTEC Mycobacteria Growth Indicator Tube 960 (MGIT) and Ogawa media among patients with tuberculous pleurisy. Out of 104 effusion samples, 43 (41.3%) were culture positive on either the MGIT or the Ogawa media. The culture yield of MGIT was higher (40.4%, 42/104) than that of Ogawa media (18.3%, 19/104) (P<0.001). One of the samples was positive only on the Ogawa medium. The median time to positivity was faster in the MGIT (18 days, range 8-32 days) than in the Ogawa media (37 days, range 20-59 days) (P<0.001). No contamination or growth of nontuberculous mycobacterium was observed on either of the culture media. In conclusion, the automated liquid culture system could provide approximately twice as high yields and fast results in effusion culture, compared to solid media. Supplemental solid media may have a limited impact on maximizing sensitivity in effusion culture; however, further studies are required.
Legionella risk assessment in cruise ships and ferries.
Laganà, Pasqualina; Gambuzza, Maria Elsa; Delia, Santi
2017-06-12
Introduction. The increasing development of marine traffic has led to a rise in the incidence of legionellosis among travellers. It occurs in similar environments, especially closed and crowded, and aboard ships Legionella survives and multiplies easily in water pipes, spreading into the environment through air conditioning systems and water distribution points. Although in recent years in the construction of cruise ships preventive measures aimed at curbing the proliferation of Legionella (design, materials, focus on the operation and maintenance of the water system), have been taken account, little or no attention has been paid to small ships which, in many cases, are old and not well maintained. Objective. The aim of the study was to evaluate the frequency and severity of Legionella contamination in ferries and cruise ships in order to adopt more specific control measures. Materials and method. A prevalence study was carried out on 10 ferries and 6 cruise ships docking or in transit across the port of Messina (Sicily, Italy). Water and air samples collected from many critical points were tested for qualitative and quantitative identification of Legionella. Results and conclusions. Legionella pneumophila sg 1 was isolated from the samples of shower and tap water in 7 (70%) of the 10 ferries examined, and in 3 (33%) of the 6 cruise ships examined, and L. pneumophila sg 2-14 in 8 (80%) and 1 (16.7%) of these ships, respectively. No Legionella contamination was found in whirlpool baths, air and ice samples. In conclusion, the data obtained confirm higher levels of Legionella contamination in local ferries and cruise ships, underlining the need to adopt corrective actions more specific for these smaller vessels.
Primary investigations on the potential of a novel diode pumped Er:YAG laser system for bone surgery
NASA Astrophysics Data System (ADS)
Stock, Karl; Diebolder, Rolf; Hausladen, Florian; Wurm, Holger; Lorenz, Swetlana; Hibst, Raimund
2013-03-01
Flashlamp pumped Er:YAG-lasers are successfully clinically used for both precise soft and hard tissue ablation. As an alternative, actually a novel diode pumped Er:YAG laser system (Pantec Engineering AG) becomes available, with mean laser power up to 15W and pulse repetition rate up to 1kHz. The aim of the presented study is to investigate the effect of this laser system on bone tissue at various irradiation parameters, particular at repetition rates exceeding 100 Hz. For reproducible experiments, firstly an appropriate experimental set-up was realized with a beam delivery and focusing unit, a computer controlled stepper unit with sample holder, and a shutter unit. It allowed to move the sample (1mm- 3mm sawed slices of pig bone) with a defined velocity while irradiation by various laser parameters. A water spray served to moisten the sample surfaces. After irradiation the grooves were analyzed by light microscopy and laser scanning microscopy regarding to the ablation quality, the groove geometry, the ablation efficacy, and the thermal effects. The resulting grooves are slightly cone shaped (groove depth up to 3mm, width about 200μm) with sharp edges at the surface. At 1W, 200Hz, 5mm/s sample movement and with water irrigation the measured ablation speed Δz/Δt is 10.8 mm/s. The ablation depth per pulse is 54μm. In conclusion, these first experiments demonstrate that the diode pumped Er:YAG laser system is an efficient tool for use in bone surgery.
Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem
2012-01-01
Background Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA”, which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial intelligent system and Fine Needle Aspiration (FNA). Methods We studied the Features of Wisconsin Data Base Cancer which contained about 569 FNA test samples (212 patient samples (malignant) and 357 healthy samples (benign)). In this research, we combined Artificial Intelligence Approaches, such as Evolutionary Algorithm (EA) with Genetic Algorithm (GA), and also used Exact Classifier Systems (here by Fuzzy C-Means (FCM)) to separate malignant from benign samples. Furthermore, we examined artificial Neural Networks (NN) to identify the model and structure. This research proposed a new algorithm for an accurate diagnosis of breast cancer. Results According to Wisconsin Data Base Cancer (WDBC) data base, 62.75% of samples were benign, and 37.25% were malignant. After applying the proposed algorithm, we achieved high detection accuracy of about "96.579%” on 205 patients who were diagnosed as having breast cancer. It was found that the method had 93% sensitivity, 73% specialty, 65% positive predictive value, and 95% negative predictive value, respectively. If done by experts, Fine Needle Aspiration (FNA) can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. FNA can be the first line of diagnosis in women with breast masses, at least in deprived regions, and may increase health standards and clinical supervision of patients. Conclusion Such a smart, economical, non-invasive, rapid and accurate system can be introduced as a useful diagnostic system for comprehensive treatment of breast cancer. Another advantage of this method is the possibility of diagnosing breast abnormalities. If done by experts, FNA can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. PMID:25352966
Bonte, Anja; Neuweger, Heiko; Goesmann, Alexander; Thonar, Cécile; Mäder, Paul; Langenkämper, Georg; Niehaus, Karsten
2014-10-01
Identification of biomarkers capable of distinguishing organic and conventional products would be highly welcome to improve the strength of food quality assurance. Metabolite profiling was used for biomarker search in organic and conventional wheat grain (Triticum aestivum L.) of 11 different old and new bread wheat cultivars grown in the DOK system comparison trial. Metabolites were extracted using methanol and analysed by gas chromatography-mass spectrometry. Altogether 48 metabolites and 245 non-identified metabolites (TAGs) were detected in the cultivar Runal. Principal component analysis showed a sample clustering according to farming systems and significant differences in peak areas between the farming systems for 10 Runal metabolites. Results obtained from all 11 cultivars indicated a greater influence of the cultivar than the farming system on metabolite concentrations. Nevertheless, a t-test on data of all cultivars still detected 5 metabolites and 11 TAGs with significant differences between the farming systems. Based on individual cultivars, metabolite profiling showed promising results for the categorization of organic and conventional wheat. Further investigations are necessary with wheat from more growing seasons and locations before definite conclusions can be drawn concerning the feasibility to evolve a combined set of biomarkers for organically grown wheat using metabolite profiles. © 2014 Society of Chemical Industry.
Metal Abundances at z<1.5: Fresh Clues to the Chemical Enrichment History of Damped Lyα Systems
NASA Astrophysics Data System (ADS)
Pettini, Max; Ellison, Sara L.; Steidel, Charles C.; Bowen, David V.
1999-01-01
We explore the redshift evolution of the metal content of damped Lyα systems (DLAs) with new observations of four absorbers at z<1.5 together with other recently published data, there is now a sample of 10 systems at intermediate redshifts for which the abundance of Zn has been measured. The main conclusion is that the column density-weighted mean metallicity, [
Yağmur, Gülhan; Albayrak, Nurhan; Daş, Taner; Yıldırım, Muzaffer; Ozgün, Ayşe; Büyük, Yalçın
2014-10-01
Tuberculosis (TB) is one of those infections with high morbidity and mortality in all around the world. Hundreds of people died from this disease without diagnosed or due to resistant strains in Turkey. Therefore, it is important to identify postmortem cases who have died from tuberculosis. Molecular methods have been widely used as well as conventional methods in the diagnosis of tuberculosis. The aim of this study was to compare the two different real-time polymerase chain reaction (Rt-PCR) system in the postmortem diagnosis of Mycobacterium tuberculosis infections in paraffin-embedded tissues. A total of 40 paraffin-embedded tissue samples [lung (n= 35), brain (n= 2), heart (n= 2), lymph node (n= 1)] in which histopathologic findings consistent with TB (necrotizing granulomatous inflammation, gelatinous caseous pneumonia, necrotic fibrous nodul) obtained from 37 autopsy cases (31 male, 6 female; age range: 25-85 yrs) were included in the study. Paraffin-embedded tissues were deparafinized with xylene and ethyl alcohol and then DNA isolation was done with QIAsymphony DSP Virus/Pathogen Midi kit in the QIAsymphony device. DNA amplification process was performed by Rt-PCR using the kit Artus® M. tuberculosis RG-PCR in the Rotor-Gene® Q device (Qiagen, Germany). Likewise, after deparafinization process, samples placed in the cartridge and isolation and Rt-PCR was performed by Xpert® MTB/RIF (Cepheid, USA) system, simultaneosly. Seventeen and 20 out of the 40 paraffin-embedded tissues yielded positive results with Qiagen and Xpert system, respectively. M.tuberculosis DNA was found positive in 13 (32.5%) and negative in 16 (40%) of the samples by both of the systems, exhibiting 72.5% (29/40) of concordance. On the other hand, seven (17.5%) samples that were positive with Xpert system yielded negative result with the Qiagen, while four (10%) samples that were positive with Qiagen yielded negative result with the Xpert system. Of the 20 positive cases detected with Xpert MTB/RIF system, 15 were found rifampicin-susceptible, and three were rifampicin-resistant. In two samples in which M. tuberculosis DNA was low positive, rifampicin resistance could not be detected. The identification of M.tuberculosis infections in postmortem cases will contribute epidemiological data in Turkey. In these cases, effective sampling and diagnosing of M.tuberculosis infections by acid-fast stain and culture methods are crucial. However, in cases without microbiological sampling the detection of M.tuberculosis DNA in paraffin-embedded tissues with PCR, although there are differences between PCR systems has diagnostic value. In conclusion, our data indicated that Xpert MTB/RIF system is more favourable to detect M.tuberculosis DNA in paraffin-embedded tissues, with the advantages of determination of rifampicin resistance, and detection of more positive results within a shorter time.
NASA Technical Reports Server (NTRS)
James, John T.
2001-01-01
The toxicological assessment of air samples returned at the end of the STS-100 (6A) flight to the ISS is reported. ISS air samples were taken in March and April 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. An unplanned "first-entry" sample of the MPLM2 (multipurpose logistics module) atmosphere was taken with a GSC, and preflight and end-of-mission samples were obtained from Endeavour using GSCs. Analytical methods have not changed from earlier reports, and all quality control measures were met for the data presented herein. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contribution). Because of the Freon 218 (octafluoropropane, OFP) leak, its contribution to the NMVOC is indicated in brackets. When comparing the NMVOC values with the 25 mg/cubic m guideline, the OFP contributions should be subtracted. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols were also assessed in each sample.
NASA Astrophysics Data System (ADS)
Bagchi, A.; Sarkar, S.; Mukhopadhyay, P. K.
2018-02-01
Three different coloured focused laser beams were used to study the photo induced microactuation effect found in some ferromagnetic shape memory alloys. Besides trying to uncover the basic causes of this unique and as yet unexplained effect, these studies are to help find other conditions to further characterize the effect for practical use. In this study some mechanisms have been proposed to control the amplitude of actuation of the sample. Control of the actuation of the FSMA sample both linearly with the help of a continuously variable neutral density filter as well periodically with the help of a linear polarizer was achieved. Statistical analysis of the experimental data was also done by applying ANOVA studies on the data to conclusively provide evidence in support of the relationship between the actuation of the sample and the various controlling factors. This study is expected to pave the way to implement this property of the sample in fabricating and operating useful micro-mechanical systems in the near future.
NASA Astrophysics Data System (ADS)
Bagchi, A.; Sarkar, S.; Mukhopadhyay, P. K.
2018-07-01
Three different coloured focused laser beams were used to study the photo induced microactuation effect found in some ferromagnetic shape memory alloys. Besides trying to uncover the basic causes of this unique and as yet unexplained effect, these studies are to help find other conditions to further characterize the effect for practical use. In this study some mechanisms have been proposed to control the amplitude of actuation of the sample. Control of the actuation of the FSMA sample both linearly with the help of a continuously variable neutral density filter as well periodically with the help of a linear polarizer was achieved. Statistical analysis of the experimental data was also done by applying ANOVA studies on the data to conclusively provide evidence in support of the relationship between the actuation of the sample and the various controlling factors. This study is expected to pave the way to implement this property of the sample in fabricating and operating useful micro-mechanical systems in the near future.
Novel nanoliposomal encapsulated omega-3 fatty acids and their applications in food.
Rasti, Babak; Erfanian, Arezoo; Selamat, Jinap
2017-09-01
The aim of the present research was to evaluate the application, stability and suitability of ω3 polyunsaturated fatty acids (PUFAs) incorporated nanoliposomes in food enrichment. Nanoliposomal ω3 PUFAs was prepared by Mozafari method, and their application in bread and milk was compared with unencapsulated (fish oil) and microencapsulated ω3 PUFAs. Sensory evaluation was conducted to determine the perceptible sensory difference/similarity between control, unencapsulated, microencapsulated, and nanoliposomal ω3 PUFAs enriched foods. Results showed no significant (p=0.11) detectable difference between control and nanoliposomal ω3 PUFAs enriched samples while, samples enriched with unencapsulated or microencapsulated ω3 PUFAs showed significant (p=0.02) fishy flavor. Moreover, significantly (p<0.01) higher ω3 PUFAs % recovery and lower peroxide and anisidine values were observed in nanoliposomal ω3 PUFAs enriched samples in comparison with other samples. In conclusion, an effective and reproducible method for application of ω3 PUFAs in the food system was developed. Copyright © 2017 Elsevier Ltd. All rights reserved.
Mosad and Stream Vision For A Telerobotic, Flying Camera System
NASA Technical Reports Server (NTRS)
Mandl, William
2002-01-01
Two full custom camera systems using the Multiplexed OverSample Analog to Digital (MOSAD) conversion technology for visible light sensing were built and demonstrated. They include a photo gate sensor and a photo diode sensor. The system includes the camera assembly, driver interface assembly, a frame stabler board with integrated decimeter and Windows 2000 compatible software for real time image display. An array size of 320X240 with 16 micron pixel pitch was developed for compatibility with 0.3 inch CCTV optics. With 1.2 micron technology, a 73% fill factor was achieved. Noise measurements indicated 9 to 11 bits operating with 13.7 bits best case. Power measured under 10 milliwatts at 400 samples per second. Nonuniformity variation was below noise floor. Pictures were taken with different cameras during the characterization study to demonstrate the operable range. The successful conclusion of this program demonstrates the utility of the MOSAD for NASA missions, providing superior performance over CMOS and lower cost and power consumption over CCD. The MOSAD approach also provides a path to radiation hardening for space based applications.
Tsujikawa, Kenji; Kuwayama, Kenji; Miyaguchi, Hajime; Kanamori, Tatsuyuki; Iwata, Yuko T; Yoshida, Takemi; Inoue, Hiroyuki
2008-02-04
We tried to develop a library search system using a portable, attenuated total reflection Fourier transform infrared (ATR-FT-IR) spectrometer for on-site identification of 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyamphetamine (MDA) tablets. The library consisted of the spectra from mixtures of controlled drugs (e.g. MDMA and ketamine), adulterants (e.g. caffeine), and diluents (e.g. lactose). In the seven library search algorithms, the derivative correlation coefficient showed the best discriminant capability. This was enhanced by segmentation of the search area. The optimized search algorithm was validated by the positive (n=154, e.g. the standard mixtures containing the controlled drug, and the MDMA/MDA tablets confiscated) and negative samples (n=56, e.g. medicinal tablets). All validation samples except for four were judged truly. Final criteria for positive identification were decided on the basis of the results of the validation. In conclusion, a portable ATR-FT-IR spectrometer with our library search system would be a useful tool for on-site identification of amphetamine-type stimulant tablets.
Environmental Validation of Legionella Control in a VHA Facility Water System.
Jinadatha, Chetan; Stock, Eileen M; Miller, Steve E; McCoy, William F
2018-03-01
OBJECTIVES We conducted this study to determine what sample volume, concentration, and limit of detection (LOD) are adequate for environmental validation of Legionella control. We also sought to determine whether time required to obtain culture results can be reduced compared to spread-plate culture method. We also assessed whether polymerase chain reaction (PCR) and in-field total heterotrophic aerobic bacteria (THAB) counts are reliable indicators of Legionella in water samples from buildings. DESIGN Comparative Legionella screening and diagnostics study for environmental validation of a healthcare building water system. SETTING Veterans Health Administration (VHA) facility water system in central Texas. METHODS We analyzed 50 water samples (26 hot, 24 cold) from 40 sinks and 10 showers using spread-plate cultures (International Standards Organization [ISO] 11731) on samples shipped overnight to the analytical lab. In-field, on-site cultures were obtained using the PVT (Phigenics Validation Test) culture dipslide-format sampler. A PCR assay for genus-level Legionella was performed on every sample. RESULTS No practical differences regardless of sample volume filtered were observed. Larger sample volumes yielded more detections of Legionella. No statistically significant differences at the 1 colony-forming unit (CFU)/mL or 10 CFU/mL LOD were observed. Approximately 75% less time was required when cultures were started in the field. The PCR results provided an early warning, which was confirmed by spread-plate cultures. The THAB results did not correlate with Legionella status. CONCLUSIONS For environmental validation at this facility, we confirmed that (1) 100 mL sample volumes were adequate, (2) 10× concentrations were adequate, (3) 10 CFU/mL LOD was adequate, (4) in-field cultures reliably reduced time to get results by 75%, (5) PCR provided a reliable early warning, and (6) THAB was not predictive of Legionella results. Infect Control Hosp Epidemiol 2018;39:259-266.
SU-F-T-434: Development of a Fan-Beam Optical Scanner Using CMOS Array for Small Field Dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brost, E; Warmington, L; Watanabe, Y
Purpose: To design and construct a second generation optical computed tomography (OCT) system using a fan-beam with a CMOS array detector for the 3D dosimetry with polymer gel and radiochromic solid dosimeters. The system was specifically designed for the small field dosimetry. Methods: The optical scanner used a fan-beam laser, which was produced from a collimated red laser beam (λ=620 nm) with a 15-degree laser-line generating lens. The fan-beam was sent through an index-matching bath which holds the sample stage and a sample. The emerging laser light was detected with a 2.54 cm-long CMOS array detector (512 elements). The samplemore » stage rotated through the full 360 degree projection angles at 0.9-degree increments. Each projection was normalized to the unirradiated sample at the projection angle to correct for imperfections in the dosimeter. A larger sample could be scanned by using a motorized mirror and linearly translating the CMOS detector. The height of the sample stage was varied for a full 3D scanning. The image acquisition and motor motion was controlled by a computer. The 3D image reconstruction was accomplished by a fan-beam reconstruction algorithm. All the software was developed inhouse with MATLAB. Results: The scanner was used on both PRESAGE and PAGAT gel dosimeters. Irreconcilable refraction errors were seen with PAGAT because the fan beam laser line refracted away from the detector when the field was highly varying in 3D. With PRESAGE, this type of error was not seen. Conclusion: We could acquire tomographic images of dose distributions by the new OCT system with both polymer gel and radiochromic solid dosimeters. Preliminary results showed that the system was more suited for radiochromic solid dosimeters since the radiochromic dosimeters exhibited minimal refraction and scattering errors. We are currently working on improving the image quality by thorough characterization of the OCT system.« less
Remote Sensing Image Quality Assessment Experiment with Post-Processing
NASA Astrophysics Data System (ADS)
Jiang, W.; Chen, S.; Wang, X.; Huang, Q.; Shi, H.; Man, Y.
2018-04-01
This paper briefly describes the post-processing influence assessment experiment, the experiment includes three steps: the physical simulation, image processing, and image quality assessment. The physical simulation models sampled imaging system in laboratory, the imaging system parameters are tested, the digital image serving as image processing input are produced by this imaging system with the same imaging system parameters. The gathered optical sampled images with the tested imaging parameters are processed by 3 digital image processes, including calibration pre-processing, lossy compression with different compression ratio and image post-processing with different core. Image quality assessment method used is just noticeable difference (JND) subject assessment based on ISO20462, through subject assessment of the gathered and processing images, the influence of different imaging parameters and post-processing to image quality can be found. The six JND subject assessment experimental data can be validated each other. Main conclusions include: image post-processing can improve image quality; image post-processing can improve image quality even with lossy compression, image quality with higher compression ratio improves less than lower ratio; with our image post-processing method, image quality is better, when camera MTF being within a small range.
Using Remote Sensing to Determine the Spatial Scales of Estuaries
NASA Astrophysics Data System (ADS)
Davis, C. O.; Tufillaro, N.; Nahorniak, J.
2016-02-01
One challenge facing Earth system science is to understand and quantify the complexity of rivers, estuaries, and coastal zone regions. Earlier studies using data from airborne hyperspectral imagers (Bissett et al., 2004, Davis et al., 2007) demonstrated from a very limited data set that the spatial scales of the coastal ocean could be resolved with spatial sampling of 100 m Ground Sample Distance (GSD) or better. To develop a much larger data set (Aurin et al., 2013) used MODIS 250 m data for a wide range of coastal regions. Their conclusion was that farther offshore 500 m GSD was adequate to resolve large river plume features while nearshore regions (a few kilometers from the coast) needed higher spatial resolution data not available from MODIS. Building on our airborne experience, the Hyperspectral Imager for the Coastal Ocean (HICO, Lucke et al., 2011) was designed to provide hyperspectral data for the coastal ocean at 100 m GSD. HICO operated on the International Space Station for 5 years and collected over 10,000 scenes of the coastal ocean and other regions around the world. Here we analyze HICO data from an example set of major river delta regions to assess the spatial scales of variability in those systems. In one system, the San Francisco Bay and Delta, we also analyze Landsat 8 OLI data at 30 m and 15 m to validate the 100 m GSD sampling scale for the Bay and assess spatial sampling needed as you move up river.
Measuring saccade peak velocity using a low-frequency sampling rate of 50 Hz.
Wierts, Roel; Janssen, Maurice J A; Kingma, Herman
2008-12-01
During the last decades, small head-mounted video eye trackers have been developed in order to record eye movements. Real-time systems-with a low sampling frequency of 50/60 Hz-are used for clinical vestibular practice, but are generally considered not to be suited for measuring fast eye movements. In this paper, it is shown that saccadic eye movements, having an amplitude of at least 5 degrees, can, in good approximation, be considered to be bandwidth limited up to a frequency of 25-30 Hz. Using the Nyquist theorem to reconstruct saccadic eye movement signals at higher temporal resolutions, it is shown that accurate values for saccade peak velocities, recorded at 50 Hz, can be obtained, but saccade peak accelerations and decelerations cannot. In conclusion, video eye trackers sampling at 50/60 Hz are appropriate for detecting the clinical relevant saccade peak velocities in contrast to what has been stated up till now.
Exposures of tungsten nanostructures to divertor plasmas in DIII-D
Rudakov, D. L.; Wong, C. P. C.; Doerner, R. P.; ...
2016-01-22
Tungsten nanostructures (W-fuzz) prepared in the PISCES-A linear device have been found to survive direct exposure to divertor plasmas in DIII-D. W-fuzz was exposed in the lower divertor of DIII-D using the divertor material evaluation system. Two samples were exposed in lower single null (LSN) deuterium H-mode plasmas. The first sample was exposed in three discharges terminated by vertical displacement event disruptions, and the second in two discharges near the lowered X-point. More recently, three samples were exposed near the lower outer strike point in predominantly helium H-mode LSN plasmas. In all cases, the W-fuzz survived plasma exposure with littlemore » obvious damage except in the areas where unipolar arcing occurred. In conclusion, arcing is effective in W-fuzz removal, and it appears that surfaces covered with W-fuzz can be more prone to arcing than smooth W surfaces.« less
Color, flavor, and sensory characteristics of gamma-irradiated salted and fermented anchovy sauce
NASA Astrophysics Data System (ADS)
Kim, Jae Hyun; Ahn, Hyun Joo; Yook, Hong Sun; Kim, Kyong Soo; Rhee, Moon Soo; Ryu, Gi Hyung; Byun, Myung Woo
2004-02-01
Color, flavor, and sensory characteristics of irradiated salted and fermented anchovy sauce were investigated. The filtrate of salted and fermented anchovy was irradiated at 0, 2.5, 5, 7.5, and 10 kGy. After irradiation, Hunter's color values were increased, however, the color values were gradually decreased in all samples during storage. Amount of the aldehydes, esters, ketones, S-containing compounds, and the other groups were increased up to 7.5 kGy irradiation, then decreased at 10 kGy ( P<0.05), while the alcohols and furan groups were increased by irradiation. Different odor patterns were observed among samples using electronic nose system analysis. Gamma-irradiated samples showed better sensory score and the quality was sustained during storage. In conclusion, gamma irradiation of salted and fermented anchovy sauce could improve its sensory quality by reducing typical fishy smell.
The EnzymeTracker: an open-source laboratory information management system for sample tracking
2012-01-01
Background In many laboratories, researchers store experimental data on their own workstation using spreadsheets. However, this approach poses a number of problems, ranging from sharing issues to inefficient data-mining. Standard spreadsheets are also error-prone, as data do not undergo any validation process. To overcome spreadsheets inherent limitations, a number of proprietary systems have been developed, which laboratories need to pay expensive license fees for. Those costs are usually prohibitive for most laboratories and prevent scientists from benefiting from more sophisticated data management systems. Results In this paper, we propose the EnzymeTracker, a web-based laboratory information management system for sample tracking, as an open-source and flexible alternative that aims at facilitating entry, mining and sharing of experimental biological data. The EnzymeTracker features online spreadsheets and tools for monitoring numerous experiments conducted by several collaborators to identify and characterize samples. It also provides libraries of shared data such as protocols, and administration tools for data access control using OpenID and user/team management. Our system relies on a database management system for efficient data indexing and management and a user-friendly AJAX interface that can be accessed over the Internet. The EnzymeTracker facilitates data entry by dynamically suggesting entries and providing smart data-mining tools to effectively retrieve data. Our system features a number of tools to visualize and annotate experimental data, and export highly customizable reports. It also supports QR matrix barcoding to facilitate sample tracking. Conclusions The EnzymeTracker was designed to be easy to use and offers many benefits over spreadsheets, thus presenting the characteristics required to facilitate acceptance by the scientific community. It has been successfully used for 20 months on a daily basis by over 50 scientists. The EnzymeTracker is freely available online at http://cubique.fungalgenomics.ca/enzymedb/index.html under the GNU GPLv3 license. PMID:22280360
Kralev, Stefan; Haag, Benjamin; Spannenberger, Jens; Lang, Siegfried; Brockmann, Marc A.; Bartling, Soenke; Marx, Alexander; Haase, Karl-Konstantin; Borggrefe, Martin; Süselbeck, Tim
2011-01-01
Background Treatment of coronary bifurcation lesions remains challenging, beyond the introduction of drug eluting stents. Dedicated stent systems are available to improve the technical approach to the treatment of these lesions. However dedicated stent systems have so far not reduced the incidence of stent restenosis. The aim of this study was to assess the expansion of the Multi-Link (ML) Frontier™ stent in human and porcine coronary arteries to provide the cardiologist with useful in-vitro information for stent implantation and selection. Methodology/Principal Findings Nine ML Frontier™ stents were implanted in seven human autopsy heart samples with known coronary artery disease and five ML Frontier™ stents were implanted in five porcine hearts. Proximal, distal and side branch diameters (PD, DD, SBD, respectively), corresponding opening areas (PA, DA, SBA) and the mean stent length (L) were assessed by micro-computed tomography (micro-CT). PD and PA were significantly smaller in human autopsy heart samples than in porcine heart samples (3.54±0.47 mm vs. 4.04±0.22 mm, p = 0.048; 10.00±2.42 mm2 vs. 12.84±1.38 mm2, p = 0.034, respectively) and than those given by the manufacturer (3.54±0.47 mm vs. 4.03 mm, p = 0.014). L was smaller in human autopsy heart samples than in porcine heart samples, although data did not reach significance (16.66±1.30 mm vs. 17.30±0.51 mm, p = 0.32), and significantly smaller than that given by the manufacturer (16.66±1.30 mm vs. 18 mm, p = 0.015). Conclusions/Significance Micro-CT is a feasible tool for exact surveying of dedicated stent systems and could make a contribution to the development of these devices. The proximal diameter and proximal area of the stent system were considerably smaller in human autopsy heart samples than in porcine heart samples and than those given by the manufacturer. Special consideration should be given to the stent deployment procedure (and to the follow-up) of dedicated stent systems, considering final intravascular ultrasound or optical coherence tomography to visualize (and if necessary optimize) stent expansion. PMID:21814552
Ahmed, Ali M.; Hamed, Dalia M.; Elsharawy, Nagwa T.
2017-01-01
Aim: The main objectives of this study were for comparing the effect of batteries and deep litter rearing systems of domesticated Japanese quail, Coturnix coturnix japonica, on the concentration levels of cadmium, copper, lead, and zinc from the quail meat and offal in Ismailia, Egypt. Materials and Methods: A total of 40 quail meat and their offal samples were randomly collected from two main quail rearing systems: Battery (Group I) and deep litter system (Group II) for determination of concentration levels of cadmium, copper, lead, and zinc. In addition, 80 water and feed samples were randomly collected from water and feeders of both systems in the Food Hygiene Laboratory, Faculty of Veterinary Medicine, Suez Canal University for heavy metals determination. Results: The mean concentration levels of cadmium, copper, lead, and zinc in Group I were 0.010, 0.027, 1.137, and 0.516 ppm and for Group II were 0.093, 0.832, 0.601, and 1.651 ppm, respectively. The mean concentration levels of cadmium, copper, lead, and zinc in quail feed in Group I were 1.114, 1.606, 5.822, and 35.11 ppm and for Group II were 3.010, 2.576, 5.852, and 23.616 ppm, respectively. The mean concentration levels of cadmium, copper, lead, and zinc in quail meat for Group I were 0.058, 5.902, 10.244, and 290 ppm and for Group II were 0.086, 6.092, 0.136, and 1.280 ppm, respectively. The mean concentration levels of cadmium, copper, lead, and zinc for liver samples in Group I were 0.15, 8.32, 1.05, and 3.41 ppm and for Group II were 0.13, 8.88, 0.95, and 4.21 ppm, respectively. The mean concentration levels of cadmium, copper, lead, and zinc in kidney samples for the Group I were 0.24, 4.21, 1.96, and 4.03 ppm and for Group II were 0.20, 5.00, 1.56, and 3.78 ppm, respectively. Kidney had the highest concentration levels of heavy metals followed by liver then muscles. The highest concentration levels of copper were observed in liver samples. The order of the levels of these trace elements obtained from the four different quail organs is Ca > Pb > Zn > Cu. Lead and cadmium concentration levels in quail meat samples were exceeded the Egyptian standardization limits and suggesting a health threat from lead and cadmium to the quail consumers. Conclusion: Battery rearing system is more hygienic than deep litter system from the point of heavy metals pollution of water and feeds of quail. Feed samples from battery system had means concentration levels of lead not significantly higher (p>0.05) than those samples from deep litter system. Meanwhile, water samples from battery system had means concentration levels of cadmium, copper, and zinc significantly higher (p>0.05) than those samples from deep litter system. Quail may carry health risks to consumers. PMID:28344413
Impact Of Standing Water On Saltstone Placement II - Hydraulic Conductivity Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cozzi, A. D.; Pickenheim, B. R.
2012-12-06
The amount of water present during placement and subsequent curing of saltstone has the potential to impact several properties important for grout quality. An active drain water system can remove residual standing water and expose the surface of the placed saltstone to air. Oxidation of the saltstone may result in an increase in the leachability of redox sensitive elements. A dry surface can lead to cracking, causing an increase in hydraulic conductivity. An inactive drain water system can allow standing water that generates unnecessary hydrostatic head on the vault walls. Standing water that cannot be removed via the drain systemmore » will be available for potential incorporation into subsequent grout placements. The objective of this work is to study the impact of standing water on grout quality pertaining to disposal units. A series of saltstone mixes was prepared and cured at ambient temperature to evaluate the impact of standing water on saltstone placement. The samples were managed to control drying effects on leachability by either exposing or capping the samples. The water to premix ratio was varied to represent a range of processing conditions. Samples were analyzed for density, leachability, and hydraulic conductivity. Report SRNL-STI-2012-00546 was issued detailing the experimental procedure, results, and conclusions related to density and leachability. In the previous report, it was concluded that: density tends to increase toward the bottom of the samples. This effect is pronounced with excess bleed water; drying of the saltstone during curing leads to decreased Leachability Index (more leaching) for potassium, sodium, rhenium, nitrite, and nitrate; there is no noticeable effect on saltstone oxidation/leachability by changing the water to premix ratio (over the range studied), or by pouring into standing water (when tested up to 10 volume percent). The hydraulic conductivity data presented in this report show that samples cured exposed to the atmosphere had about three orders of magnitude higher hydraulic conductivity than any of the other samples. Considering these data, along with the results presented in the previous report, leads to the conclusion that small changes in water to premix ratio and the inclusion of up to 10 volume percent standing water should not be expected to have a detrimental effect on saltstone grout quality. The hydraulic conductivity results further demonstrate that curing in a moist environment is critical to maintaining saltstone quality.« less
Veličković, Dušan; Chu, Rosalie K; Carrell, Alyssa A; Thomas, Mathew; Paša-Tolić, Ljiljana; Weston, David J; Anderton, Christopher R
2018-01-02
One critical aspect of mass spectrometry imaging (MSI) is the need to confidently identify detected analytes. While orthogonal tandem MS (e.g., LC-MS 2 ) experiments from sample extracts can assist in annotating ions, the spatial information about these molecules is lost. Accordingly, this could cause mislead conclusions, especially in cases where isobaric species exhibit different distributions within a sample. In this Technical Note, we employed a multimodal imaging approach, using matrix assisted laser desorption/ionization (MALDI)-MSI and liquid extraction surface analysis (LESA)-MS 2 I, to confidently annotate and localize a broad range of metabolites involved in a tripartite symbiosis system of moss, cyanobacteria, and fungus. We found that the combination of these two imaging modalities generated very congruent ion images, providing the link between highly accurate structural information onfered by LESA and high spatial resolution attainable by MALDI. These results demonstrate how this combined methodology could be very useful in differentiating metabolite routes in complex systems.
A high-mobility electronic system at an electrolyte-gated oxide surface
Gallagher, Patrick; Lee, Menyoung; Petach, Trevor A.; ...
2015-03-12
Electrolyte gating is a powerful technique for accumulating large carrier densities at a surface. Yet this approach suffers from significant sources of disorder: electrochemical reactions can damage or alter the sample, and the ions of the electrolyte and various dissolved contaminants sit Angstroms from the electron system. Accordingly, electrolyte gating is well suited to studies of superconductivity and other phenomena robust to disorder, but of limited use when reactions or disorder must be avoided. Here we demonstrate that these limitations can be overcome by protecting the sample with a chemically inert, atomically smooth sheet of hexagonal boron nitride. We illustratemore » our technique with electrolyte-gated strontium titanate, whose mobility when protected with boron nitride improves more than 10-fold while achieving carrier densities nearing 10 14 cm –2. In conclusion, our technique is portable to other materials, and should enable future studies where high carrier density modulation is required but electrochemical reactions and surface disorder must be minimized.« less
Yamada, Yutaro; Konno, Hiroki; Shimabukuro, Katsuya
2017-01-01
In this study, we present a new technique called correlative atomic force and transmission electron microscopy (correlative AFM/TEM) in which a targeted region of a sample can be observed under AFM and TEM. The ultimate goal of developing this new technique is to provide a technical platform to expand the fields of AFM application to complex biological systems such as cell extracts. Recent advances in the time resolution of AFM have enabled detailed observation of the dynamic nature of biomolecules. However, specifying molecular species, by AFM alone, remains a challenge. Here, we demonstrate correlative AFM/TEM, using actin filaments as a test sample, and further show that immuno-electron microscopy (immuno-EM), to specify molecules, can be integrated into this technique. Therefore, it is now possible to specify molecules, captured under AFM, by subsequent observation using immuno-EM. In conclusion, correlative AFM/TEM can be a versatile method to investigate complex biological systems at the molecular level. PMID:28828286
Face-Referenced Measurement of Perioral Stiffness and Speech Kinematics in Parkinson's Disease
Barlow, Steven M.; Lee, Jaehoon
2015-01-01
Purpose Perioral biomechanics, labial kinematics, and associated electromyographic signals were sampled and characterized in individuals with Parkinson's disease (PD) as a function of medication state. Method Passive perioral stiffness was sampled using the OroSTIFF system in 10 individuals with PD in a medication ON and a medication OFF state and compared to 10 matched controls. Perioral stiffness, derived as the quotient of resultant force and interoral angle span, was modeled with regression techniques. Labial movement amplitudes and integrated electromyograms from select lip muscles were evaluated during syllable production using a 4-D computerized motion capture system. Results Multilevel regression modeling showed greater perioral stiffness in patients with PD, consistent with the clinical correlate of rigidity. In the medication-OFF state, individuals with PD manifested greater integrated electromyogram levels for the orbicularis oris inferior compared to controls, which increased further after consumption of levodopa. Conclusions This study illustrates the application of biomechanical, electrophysiological, and kinematic methods to better understand the pathophysiology of speech motor control in PD. PMID:25629806
Re-Os Systematics and HSE Distribution in Metal from Ochansk (H4) Chondrite
NASA Technical Reports Server (NTRS)
Smoliar, M. I.; Horan, M. F.; Alexander, C. M. OD.; Walker, R. J.
2003-01-01
Previous studies of the Re-Os systematics of chondrites have documented considerable variation in the Re/Os ratios of whole rock samples. For some whole rock chondrites, Re-Os systematics display large deviations from the primitive isochron that are considerably larger than deviations in other isotope systems. Possible interpretation of these facts is that the Re-Os system in chondrites is particularly sensitive to post-formation alteration processes, thus providing a useful tool to examine such processes. Significant variations that have been detected in highly siderophile element (HSE) patterns for ordinary chondrites support this conclusion. We report Re-Os isotope data for metal separates from the Ochansk H4 chondrite coupled with abundance data for Ru, Pd, Ir, and Pt, determined in the same samples by isotope dilution. We chose this meteorite mainly because it is an observed fall with minimal signs of weathering, and its low metamorphic grade (H4) and shock stage (S3).
Immune system changes during simulated planetary exploration on Devon Island, high arctic
Crucian, Brian; Lee, Pascal; Stowe, Raymond; Jones, Jeff; Effenhauser, Rainer; Widen, Raymond; Sams, Clarence
2007-01-01
Background Dysregulation of the immune system has been shown to occur during spaceflight, although the detailed nature of the phenomenon and the clinical risks for exploration class missions have yet to be established. Also, the growing clinical significance of immune system evaluation combined with epidemic infectious disease rates in third world countries provides a strong rationale for the development of field-compatible clinical immunology techniques and equipment. In July 2002 NASA performed a comprehensive immune assessment on field team members participating in the Haughton-Mars Project (HMP) on Devon Island in the high Canadian Arctic. The purpose of the study was to evaluate the effect of mission-associated stressors on the human immune system. To perform the study, the development of techniques for processing immune samples in remote field locations was required. Ten HMP-2002 participants volunteered for the study. A field protocol was developed at NASA-JSC for performing sample collection, blood staining/processing for immunophenotype analysis, whole-blood mitogenic culture for functional assessments and cell-sample preservation on-location at Devon Island. Specific assays included peripheral leukocyte distribution; constitutively activated T cells, intracellular cytokine profiles, plasma cortisol and EBV viral antibody levels. Study timepoints were 30 days prior to mission start, mid-mission and 60 days after mission completion. Results The protocol developed for immune sample processing in remote field locations functioned properly. Samples were processed on Devon Island, and stabilized for subsequent analysis at the Johnson Space Center in Houston. The data indicated that some phenotype, immune function and stress hormone changes occurred in the HMP field participants that were largely distinct from pre-mission baseline and post-mission recovery data. These immune changes appear similar to those observed in astronauts following spaceflight. Conclusion The immune system changes described during the HMP field deployment validate the use of the HMP as a ground-based spaceflight/planetary exploration analog for some aspects of human physiology. The sample processing protocol developed for this study may have applications for immune studies in remote terrestrial field locations. Elements of this protocol could possibly be adapted for future in-flight immunology studies conducted during space missions. PMID:17521440
2012-01-01
Background Despite computational challenges, elucidating conformations that a protein system assumes under physiologic conditions for the purpose of biological activity is a central problem in computational structural biology. While these conformations are associated with low energies in the energy surface that underlies the protein conformational space, few existing conformational search algorithms focus on explicitly sampling low-energy local minima in the protein energy surface. Methods This work proposes a novel probabilistic search framework, PLOW, that explicitly samples low-energy local minima in the protein energy surface. The framework combines algorithmic ingredients from evolutionary computation and computational structural biology to effectively explore the subspace of local minima. A greedy local search maps a conformation sampled in conformational space to a nearby local minimum. A perturbation move jumps out of a local minimum to obtain a new starting conformation for the greedy local search. The process repeats in an iterative fashion, resulting in a trajectory-based exploration of the subspace of local minima. Results and conclusions The analysis of PLOW's performance shows that, by navigating only the subspace of local minima, PLOW is able to sample conformations near a protein's native structure, either more effectively or as well as state-of-the-art methods that focus on reproducing the native structure for a protein system. Analysis of the actual subspace of local minima shows that PLOW samples this subspace more effectively that a naive sampling approach. Additional theoretical analysis reveals that the perturbation function employed by PLOW is key to its ability to sample a diverse set of low-energy conformations. This analysis also suggests directions for further research and novel applications for the proposed framework. PMID:22759582
Regional incentives and patient cross-border mobility: evidence from the Italian experience
Brenna, Elenka; Spandonaro, Federico
2015-01-01
Background: In recent years, accreditation of private hospitals followed by decentralisation of the Italian National Health Service (NHS) into 21 regional health systems has provided a good empirical ground for investigating the Tiebout principle of "voting with their feet". We examine the infra-regional trade-off between greater patient choice (due to an increase in hospital services supply) and financial equilibrium, and we relate it to the significant phenomenon of Cross-Border Mobility (CBM) between Italian regions. Focusing on the rules supervising the financial agreements between regional authorities and providers of hospital care, we find incentives for private accredited providers in attracting patient inflows. Methods: The analysis is undertaken from an institutional, regulatory and empirical perspective. We select a sample of five regions with higher positive CBM balance and we examine regional regulations governing the contractual agreements between purchasers and providers of hospital care. According to this sample, we provide a statistical analysis of CBM and apply a Regional Attraction Ability Index (RAAI), aimed at testing patient preferences for private/public accredited providers. Results: We find that this index is systematically higher for private providers, both in the case of distance/boundary patients and of excellence/general hospitals. Conclusion: Conclusions address both financial issues regarding the coverage of regional healthcare systems and equity issues on patient healthcare access. They also raise concerns on the new European Union (EU) directive inherent to patient mobility across Europe. PMID:26029895
Measuring Water Quality in Hong Kong using an Underwater Remotely Operated Vehicle
NASA Astrophysics Data System (ADS)
Evans, J. W.
2017-12-01
Clean water is a vital necessity in our day to day lives, with all living organisms depending on it for survival and countless others relying on it as their habitat. The waters surrounding Hong Kong are home to a wide diversity of marine animals and organisms but are polluted for a variety of reasons. This pollution includes marine debris, industrial and construction waste, a high concentration of organic material, and other pollutants. This research project will focus on collecting water and soil samples from various locations around the Hong Kong ocean waters for analytical chemical sampling. A Remote Operated Vehicle (ROV) will be designed, built and used for collecting the water and soil samples. ROVs are used around the world in oceans and other deep water applications. ThisROV will be tethered with a control system and equipped with a camera, mechanical arms for collections water and soil samples and sensors for testing basic water parameters. Using a ROV will allow for long term sampling in the same location to occur as required. The collected samples will be tested in the lab to determine overall water and soil quality, allowing conclusions to be drawn about the conditions of the tested area.
Deep Charging Evaluation of Satellite Power and Communication System Components
NASA Technical Reports Server (NTRS)
Schneider, T. A.; Vaughn, J. A.; Chu, B.; Wong, F.; Gardiner, G.; Wright, K. H.; Phillips, B.
2016-01-01
Deep charging, in contrast to surface charging, focuses on electron penetration deep into insulating materials applied over conductors. A classic example of this scenario is an insulated wire. Deep charging can pose a threat to material integrity, and to sensitive electronics, when it gives rise to an electrostatic discharge or arc. With the advent of Electric Orbit Raising, which requires spiraling through Earth's radiation belts, satellites are subjected to high energy electron environments which they normally would not encounter. Beyond Earth orbit, missions to Jupiter and Saturn face deep charging concerns due to the high energy radiation environments. While predictions can be made about charging in insulating materials, it is difficult to extend those predictions to complicated geometries, such as the case of an insulating coating around a small wire, or a non-uniform silicone grouting on a bus bar. Therefore, to conclusively determine the susceptibility of a system to arcs from deep charging, experimental investigations must be carried out. This paper will describe the evaluation carried out by NASA's Marshall Space Flight Center on subscale flight-like samples developed by Space Systems/Loral, LLC. Specifically, deep charging evaluations of solar array wire coupons, a photovoltaic cell coupon, and a coaxial microwave transmission cable, will be discussed. The results of each evaluation will be benchmarked against control sample tests, as well as typical power system levels, to show no significant deep charging threat existed for this set of samples under the conditions tested.
NASA Technical Reports Server (NTRS)
Edwards, D. L.
1993-01-01
This report focuses on the development of an operational Rutherford backscattering spectrometry (RBS) system and shows the application of such a system on a space environmental test. Thin films of aluminum and tantalum were deposited on diamond substrates. These films were anodized and preexposure characterization spectra obtained using RBS and total hemispherical reflectance. The samples were exposed to energetic protons then postexposure characterization spectra was obtained using the same techniques. Conclusions based on the comparison of preexposure and postexposure spectra are presented. RBS comparison spectra show no change in the metal/metal oxide interface, while the comparison reflectance data indicate change. Explanations for this reflectance change are presented in this report.
System of Mueller-Jones matrix polarizing mapping of blood plasma films in breast pathology
NASA Astrophysics Data System (ADS)
Zabolotna, Natalia I.; Radchenko, Kostiantyn O.; Tarnovskiy, Mykola H.
2017-08-01
The combined method of Jones-Mueller matrix mapping and blood plasma films analysis based on the system that proposed in this paper. Based on the obtained data about the structure and state of blood plasma samples the diagnostic conclusions can be make about the state of breast cancer patients ("normal" or "pathology"). Then, by using the statistical analysis obtain statistical and correlational moments for every coordinate distributions; these indicators are served as diagnostic criterias. The final step is to comparing results and choosing the most effective diagnostic indicators. The paper presents the results of Mueller-Jones matrix mapping of optically thin (attenuation coefficient ,τ≤0,1) blood plasma layers.
Does laboratory automation for the preanalytical phase improve data quality?
Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Danese, Elisa; Montagnana, Martina; Brocco, Giorgio; Voi, Monica; Picheth, Geraldo; Guidi, Gian Cesare
2013-10-01
Our aim was to evaluate whether automation for the preanalytical phase improves data quality. Blood from 100 volunteers was collected into two vacuum tubes. One sample from each volunteer was respectively assigned to (G1) traditional processing, starting with centrifugation at 1200 g for 10 min, and (G2) the MODULAR PRE-ANALYTICALS EVO-MPA system. The routine clinical chemistry tests were performed in duplicate on the same instrument Cobas 6000
Mugisha, Frederick; Bocar, Kouyate; Dong, Hengjin; Chepng'eno, Gloria; Sauerborn, Rainer
2004-01-01
OBJECTIVE: To explore the factors that determine whether a patient will initiate treatment within a system of health-care services, and the factors that determine whether the patient will be retained in the chosen system, in Nouna, rural Burkina Faso. METHODS: The data used were pooled from four rounds of a household survey conducted in Nouna, rural Burkina Faso. The ongoing demographic surveillance system provided a sampling framework for this survey in which 800 households were sampled using a two-stage cluster sampling procedure. More than one treatment episode was observed for a single episode of illness per patient. The multinomial logit model was used to explore the determinants of patient initiation to systems of modern, traditional and home treatment, and a binary logit model was used to explore the determinants of patient retention within the chosen health-care provider system. FINDINGS: The results suggest that the determinants of patient initiation and their subsequent retention are different. Household income, education, urban residence and expected competency of the provider are positive predictors of initiation, but not of retention, for modern health-care services. Only perceived quality of care positively predicted retention in modern health-care services. CONCLUSION: Interventions focusing on patient initiation and patient retention are likely to be different. Policies directed at enhancing initiation for modern health-care services would primarily focus on reducing financial barriers, while those directed at increasing retention would primarily focus on attributes that improve the perceived quality of care. PMID:15375446
PIMS sequencing extension: a laboratory information management system for DNA sequencing facilities
2011-01-01
Background Facilities that provide a service for DNA sequencing typically support large numbers of users and experiment types. The cost of services is often reduced by the use of liquid handling robots but the efficiency of such facilities is hampered because the software for such robots does not usually integrate well with the systems that run the sequencing machines. Accordingly, there is a need for software systems capable of integrating different robotic systems and managing sample information for DNA sequencing services. In this paper, we describe an extension to the Protein Information Management System (PIMS) that is designed for DNA sequencing facilities. The new version of PIMS has a user-friendly web interface and integrates all aspects of the sequencing process, including sample submission, handling and tracking, together with capture and management of the data. Results The PIMS sequencing extension has been in production since July 2009 at the University of Leeds DNA Sequencing Facility. It has completely replaced manual data handling and simplified the tasks of data management and user communication. Samples from 45 groups have been processed with an average throughput of 10000 samples per month. The current version of the PIMS sequencing extension works with Applied Biosystems 3130XL 96-well plate sequencer and MWG 4204 or Aviso Theonyx liquid handling robots, but is readily adaptable for use with other combinations of robots. Conclusions PIMS has been extended to provide a user-friendly and integrated data management solution for DNA sequencing facilities that is accessed through a normal web browser and allows simultaneous access by multiple users as well as facility managers. The system integrates sequencing and liquid handling robots, manages the data flow, and provides remote access to the sequencing results. The software is freely available, for academic users, from http://www.pims-lims.org/. PMID:21385349
NASA Astrophysics Data System (ADS)
Larsen, Erik H.
1998-02-01
Achievement of optimum selectivity, sensitivity and robustness in speciation analysis using high performance liquid chromatography (HPLC) with inductively coupled mass spectrometry (ICP-MS) detection requires that each instrumental component is selected and optimized with a view to the ideal operating characteristics of the entire hyphenated system. An isocratic HPLC system, which employs an aqueous mobile phase with organic buffer constituents, is well suited for introduction into the ICP-MS because of the stability of the detector response and high degree of analyte sensitivity attained. Anion and cation exchange HPLC systems, which meet these requirements, were used for the seperation of selenium and arsenic species in crude extracts of biological samples. Furthermore, the signal-to-noise ratios obtained for these incompletely ionized elements in the argon ICP were further enhanced by a factor of four by continously introducing carbon as methanol via the mobile phase into the ICP. Sources of error in the HPLC system (column overload), in the sample introduction system (memory by organic solvents) and in the ICP-MS (spectroscopic interferences) and their prevention are also discussed. The optimized anion and cation exchange HPLC-ICP-MS systems were used for arsenic speciation in contaminated ground water and in an in-house shrimp reference sample. For the purpose of verification, HPLC coupled with tandem mass spectrometry with electrospray ionization was additionally used for arsenic speciation in the shrimp sample. With this analytical technique the HPLC retention time in combination with mass analysis of the molecular ions and their collision-induced fragments provide almost conclusive evidence of the identity of the analyte species. The speciation methods are validated by establishing a mass balance of the analytes in each fraction of the extraction procedure, by recovery of spikes and by employing and comparing independent techniques. The urgent need for reference materials certified for elemental species is stressed.
Ashraf, Hengameh; Samiee, Mohammad; Eslami, Gita; Ghodse Hosseini, Mohammad Reza
2007-01-01
INTRODUCTION: An important consideration in endodontic treatment is the elimination of microorganisms, including fungi, from the complex three- dimensional root canal system. Candida Albicans (CA) has a major role in endodontic treatment failure as the most important fungus isolated from the root canal system. The present study was carried out to evaluate the presence of CA in the teeth requiring endodontic retreatment, with or without periapical lesions. MATERIALS AND METHODS: This study was carried out on 60 root canals from human molars requiring endodontic retreatment. The root canals were randomly divided into two equal groups of 30 canals with versus without periapical lesions. Samples were collected from the root canals and cultured on MacConkey and blood agar culture media. The samples suspected of having CA were streaked on Sabouraud’s Dextrose Agar (SDA) and evaluated under a light microscope. Data was analyzed and compared using Chi- square and Kappa tests. RESULTS: CA was found in 11 patients (36.7%) with periapical lesions. In the patients without periapical lesions only 4 samples demonstrated CA in the root canal systems (13.3%). The difference between the two groups as to the presence of CA was statistically significant (p<0.037). In addition, evaluation of salivary samples revealed 15 cases (50%) of CA presence in the patients with periapical lesions and 16 cases (53.3%) of CA in the patients without periapical lesions, demonstrating no statistically significant difference between the two groups. CONCLUSION: Considering the fact that the presence of CA in the root canal systems of teeth with periapical lesions was more noticeable and statistically significant compared to the teeth without periapical lesions, the elimination of this microorganism from the root canal system, using appropriate intracanal solutions and medications is of utmost importance. PMID:24348654
Beyer, Andreas; Grohganz, Holger; Löbmann, Korbinian; Rades, Thomas; Leopold, Claudia S
2017-06-30
Improvement of the physicochemical properties of amorphous active pharmaceutical ingredients (APIs) applying the concept of co-amorphisation is a promising alternative to the use of polymer glass solutions. In co-amorphous systems, the physical stability and the dissolution rate of the involved components may be improved in comparison to the respective single amorphous phases. However, for the co-amorphous naproxen-indomethacin model system it has been reported that recrystallization could not be prevented for more than 112days regardless of the applied preparation method and blend ratio In the present study, it was thus tested if the physicochemical properties of co-amorphous naproxen-indomethacin could be optimized by incorporation of the naproxen sodium into the system. Three different co-amorphous systems in nine different molar ratios were prepared by quench-cooling: naproxen-indomethacin (NI), naproxen-sodium-naproxen-indomethacin (NSNI) and naproxen-sodium-indomethacin (NSI). The samples were analyzed by XRPD, FTIR, DSC and by intrinsic dissolution experiments to investigate the influence of naproxen-sodium on the resulting physicochemical properties of the systems. With the three systems, fully amorphous samples with single glass transition temperatures could be prepared with naproxen molar fractions up to 0.7. The NSI and NSNI systems showed up to about 40°C higher Tgs than the NI system. Furthermore, no recrystallization occurred during 270d of storage with the NSI and NSNI samples that were initially amorphous. Moreover, with the NSI system, the intrinsic dissolution rate of naproxen and indomethacin was improved by a factor of 2 compared to the unmodified NI system. In conclusion, the physical stability as well as the dissolution rate was significantly improved if partial or full exchange of naproxen by its sodium salt was performed, which may present a general optimization method to improve co-amorphous systems. Copyright © 2017 Elsevier B.V. All rights reserved.
Balejo, Rodrigo Dalla Pria; Cortelli, José Roberto; Costa, Fernando Oliveira; Cyrino, Renata Magalhães; Aquino, Davi Romeiro; Cogo-Müller, Karina; Miranda, Taís Browne; Moura, Sara Porto; Cortelli, Sheila Cavalca
2017-01-01
Abstract Objective: Single dose of systemic antibiotics and short-term use of mouthwashes reduce bacteremia. However, the effects of a single dose of preprocedural rinse are still controversial. This study evaluated, in periodontally diseased patients, the effects of a pre-procedural mouth rinse on induced bacteremia. Material and Methods: Systemically healthy individuals with gingivitis (n=27) or periodontitis (n = 27) were randomly allocated through a sealed envelope system to: 0.12% chlorhexidine pre-procedural rinse (13 gingivitis and 13 periodontitis patients) or no rinse before dental scaling (14 gingivitis and 15 periodontitis patients). Periodontal probing depth, clinical attachment level, plaque, and gingival indices were measured and subgingival samples were collected. Blood samples were collected before dental scaling, 2 and 6 minutes after scaling. Total bacterial load and levels of P. gingivalis were determined in oral and blood samples by real-time polymerase chain reaction, while aerobic and anaerobic counts were determined by culture in blood samples. The primary outcome was the antimicrobial effect of the pre-procedural rinse. Data was compared by Mann-Whitney and Signal tests (p<0.05). Results: In all sampling times, polymerase chain reaction revealed higher blood bacterial levels than culture (p<0.0001), while gingivitis patients presented lower bacterial levels in blood than periodontitis patients (p<0.0001). Individuals who experienced bacteremia showed worse mean clinical attachment level (3.4 mm vs. 1.1 mm) and more subgingival bacteria (p<0.005). The pre-procedural rinse did not reduce induced bacteremia. Conclusions: Bacteremia was influenced by periodontal parameters. In periodontally diseased patients, pre-procedural rinsing showed a discrete effect on bacteremia control. PMID:29211279
Molecular comparison of the sampling efficiency of four types of airborne bacterial samplers.
Li, Kejun
2011-11-15
In the present study, indoor and outdoor air samples were collected using four types of air samplers often used for airborne bacterial sampling. These air samplers included two solid impactors (BioStage and RCS), one liquid impinger (BioSampler), and one filter sampler with two kinds of filters (a gelatin and a cellulose acetate filter). The collected air samples were further processed to analyze the diversity and abundance of culturable bacteria and total bacteria through standard culture techniques, denaturing gradient gel electrophoresis (DGGE) fingerprinting and quantitative polymerase chain reaction (qPCR) analysis. The DGGE analysis indicated that the air samples collected using the BioStage and RCS samplers have higher culturable bacterial diversity, whereas the samples collected using the BioSampler and the cellulose acetate filter sampler have higher total bacterial diversity. To obtain more information on the sampled bacteria, some gel bands were excised and sequenced. In terms of sampling efficiency, results from the qPCR tests indicated that the collected total bacterial concentration was higher in samples collected using the BioSampler and the cellulose acetate filter sampler. In conclusion, the sampling bias and efficiency of four kinds of air sampling systems were compared in the present study and the two solid impactors were concluded to be comparatively efficient for culturable bacterial sampling, whereas the liquid impactor and the cellulose acetate filter sampler were efficient for total bacterial sampling. Copyright © 2011 Elsevier B.V. All rights reserved.
Riddell, Michaela A.; Byrnes, Graham B.; Leydon, Jennie A.; Kelly, Heath A.
2003-01-01
OBJECTIVES: To determine whether samples of dried venous blood (DVB) were an acceptable alternative to serum for detecting measles-specific IgG in a commercial enzyme immunoassay. METHODS: Paired samples of serum and DVB were collected from 98 suspected cases of measles and 1153 schoolchildren in Victoria, Australia. All samples were tested using the Dade Behring Enzygnost Anti-Measles-Virus/IgG immunoassay. DVB samples were eluted using either the sample buffer provided with the kit or 5% dry milk powder in phosphate-buffered saline-Tween 20. FINDINGS: DVB samples eluted by sample buffer showed significantly better linear correlation to the serum samples than did DVB samples eluted in 5% dry milk in phosphate-buffered saline-Tween 20. To improve the comparability of serum and DVB samples an adjustment factor of 1.28 was applied to the optical density (OD) values of DVB. This adjustment also enabled quantification of the titre of measles IgG in mIU/ml directly from the OD value using the alpha calculation as specified by the kit protocol. For DVB samples stored for less than six months at 4 degrees C, the assay showed an overall sensitivity of 98.4% and a specificity of 97.2% compared with the results of serum testing. CONCLUSION: These results illustrate the potential for DVB samples to be widely used with the Dade Behring enzyme immunoassay system for determining the immunity of the individual and the population to the measles virus. PMID:14758429
Emergent Optical Phononic Modes upon Nanoscale Mesogenic Phase Transitions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolmatov, Dima; Zhernenkov, Mikhail; Sharpnack, Lewis
The investigation of phononic collective excitations in soft matter systems at the molecular scale has always been challenging due to limitations of experimental techniques in resolving low-energy modes. Recent advances in inelastic X-ray scattering (IXS) enabled the study of such systems with unprecedented spectral contrast at meV excitation energies. In particular, it has become possible to shed light on the low-energy collective motions in materials whose morphology and phase behavior can easily be manipulated, such as mesogenic systems. The understanding of collective mode behavior with a Q-dependence is the key to implement heat management based on the control of amore » sample structure. The latter has great potential for a large number of energy-inspired innovations. As a first step toward this goal, we carried out high contrast IXS measurements on a liquid crystal sample, D7AOB, which exhibits solid-like dynamic features, such as the coexistence of longitudinal and transverse phononic modes. For the first time, we found that these terahertz phononic excitations persist in the crystal, smectic A, and isotropic phases. Furthermore, the intermediate smectic A phase is shown to support a van der Waals-mediated nonhydrodynamic mode with an optical-like phononic behavior. In conclusion, the tunability of the collective excitations at nanometer–terahertz scales via selection of the sample mesogenic phase represents a new opportunity to manipulate optomechanical properties of soft metamaterials.« less
Emergent Optical Phononic Modes upon Nanoscale Mesogenic Phase Transitions
Bolmatov, Dima; Zhernenkov, Mikhail; Sharpnack, Lewis; ...
2017-05-26
The investigation of phononic collective excitations in soft matter systems at the molecular scale has always been challenging due to limitations of experimental techniques in resolving low-energy modes. Recent advances in inelastic X-ray scattering (IXS) enabled the study of such systems with unprecedented spectral contrast at meV excitation energies. In particular, it has become possible to shed light on the low-energy collective motions in materials whose morphology and phase behavior can easily be manipulated, such as mesogenic systems. The understanding of collective mode behavior with a Q-dependence is the key to implement heat management based on the control of amore » sample structure. The latter has great potential for a large number of energy-inspired innovations. As a first step toward this goal, we carried out high contrast IXS measurements on a liquid crystal sample, D7AOB, which exhibits solid-like dynamic features, such as the coexistence of longitudinal and transverse phononic modes. For the first time, we found that these terahertz phononic excitations persist in the crystal, smectic A, and isotropic phases. Furthermore, the intermediate smectic A phase is shown to support a van der Waals-mediated nonhydrodynamic mode with an optical-like phononic behavior. In conclusion, the tunability of the collective excitations at nanometer–terahertz scales via selection of the sample mesogenic phase represents a new opportunity to manipulate optomechanical properties of soft metamaterials.« less
NASA Astrophysics Data System (ADS)
Wang, Xinyi; Shen, Jialong; Liu, Xinbo
2018-01-01
Against the technical defects of universally applicable beam tube monitoring system at present, such as air suction in the beam tube, line clogging, long sampling time, etc., the paper analyzes the current situation of the spontaneous combustion fire disaster forecast of mine in our country and these defects one by one. On this basis, the paper proposes a research thought that improving the positive pressure beam tube so as to substitute the negative pressure beam tube. Then, the paper introduces the beam tube monitoring system based on positive pressure technology through theoretical analysis and experiment. In the comparison with negative pressure beam tube, the paper concludes the advantage of the new system and draws the conclusion that the positive pressure beam tube is superior to the negative pressure beam tube system both in test result and test time. At last, the paper proposes prospect of the beam tube monitoring system based on positive pressure technology.
Heeke, Simon; Hofman, Véronique; Long-Mira, Elodie; Lespinet, Virginie; Lalvée, Salomé; Bordone, Olivier; Ribeyre, Camille; Tanga, Virginie; Benzaquen, Jonathan; Leroy, Sylvie; Cohen, Charlotte; Mouroux, Jérôme; Marquette, Charles Hugo; Ilié, Marius; Hofman, Paul
2018-03-21
Background : With the integration of various targeted therapies into the clinical management of patients with advanced lung adenocarcinoma, next-generation sequencing (NGS) has become the technology of choice and has led to an increase in simultaneously interrogated genes. However, the broader adoption of NGS for routine clinical practice is still hampered by sophisticated workflows, complex bioinformatics analysis and medical interpretation. Therefore, the performance of the novel QIAGEN GeneReader NGS system was compared to an in-house ISO-15189 certified Ion PGM NGS platform. Methods : Clinical samples from 90 patients (60 Retrospectively and 30 Prospectively) with lung adenocarcinoma were sequenced with both systems. Mutations were analyzed and EGFR , KRAS , BRAF , NRAS , ALK , PIK3CA and ERBB2 genes were compared and sampling time and suitability for clinical testing were assessed. Results : Both sequencing systems showed perfect concordance for the overlapping genes. Correlation of allele frequency was r ² = 0.93 for the retrospective patients and r ² = 0.81 for the prospective patients. Hands-on time and total run time were shorter using the PGM system, while the GeneReader platform provided good traceability and up-to-date interpretation of the results. Conclusion : We demonstrated the suitability of the GeneReader NGS system in routine practice in a clinical pathology laboratory setting.
The effect of processing on the surface physical stability of amorphous solid dispersions.
Yang, Ziyi; Nollenberger, Kathrin; Albers, Jessica; Moffat, Jonathan; Craig, Duncan; Qi, Sheng
2014-11-01
The focus of this study was to investigate the effect of processing on the surface crystallization of amorphous molecular dispersions and gain insight into the mechanisms underpinning this effect. The model systems, amorphous molecular dispersions of felodipine-EUDRAGIT® E PO, were processed both using spin coating (an ultra-fast solvent evaporation based method) and hot melt extrusion (HME) (a melting based method). Amorphous solid dispersions with drug loadings of 10-90% (w/w) were obtained by both processing methods. Samples were stored under 75% RH/room temperatures for up to 10months. Surface crystallization was observed shortly after preparation for the HME samples with high drug loadings (50-90%). Surface crystallization was characterized by powder X-ray diffraction (PXRD), ATR-FTIR spectroscopy and imaging techniques (SEM, AFM and localized thermal analysis). Spin coated molecular dispersions showed significantly higher surface physical stability than hot melt extruded samples. For both systems, the progress of the surface crystal growth followed zero order kinetics on aging. Drug enrichment at the surfaces of HME samples on aging was observed, which may contribute to surface crystallization of amorphous molecular dispersions. In conclusion it was found the amorphous molecular dispersions prepared by spin coating had a significantly higher surface physical stability than the corresponding HME samples, which may be attributed to the increased process-related apparent drug-polymer solubility and reduced molecular mobility due to the quenching effect caused by the rapid solvent evaporation in spin coating. Copyright © 2014 Elsevier B.V. All rights reserved.
Methodology for the development and calibration of the SCI-QOL item banks
Tulsky, David S.; Kisala, Pamela A.; Victorson, David; Choi, Seung W.; Gershon, Richard; Heinemann, Allen W.; Cella, David
2015-01-01
Objective To develop a comprehensive, psychometrically sound, and conceptually grounded patient reported outcomes (PRO) measurement system for individuals with spinal cord injury (SCI). Methods Individual interviews (n = 44) and focus groups (n = 65 individuals with SCI and n = 42 SCI clinicians) were used to select key domains for inclusion and to develop PRO items. Verbatim items from other cutting-edge measurement systems (i.e. PROMIS, Neuro-QOL) were included to facilitate linkage and cross-population comparison. Items were field tested in a large sample of individuals with traumatic SCI (n = 877). Dimensionality was assessed with confirmatory factor analysis. Local item dependence and differential item functioning were assessed, and items were calibrated using the item response theory (IRT) graded response model. Finally, computer adaptive tests (CATs) and short forms were administered in a new sample (n = 245) to assess test-retest reliability and stability. Participants and Procedures A calibration sample of 877 individuals with traumatic SCI across five SCI Model Systems sites and one Department of Veterans Affairs medical center completed SCI-QOL items in interview format. Results We developed 14 unidimensional calibrated item banks and 3 calibrated scales across physical, emotional, and social health domains. When combined with the five Spinal Cord Injury – Functional Index physical function banks, the final SCI-QOL system consists of 22 IRT-calibrated item banks/scales. Item banks may be administered as CATs or short forms. Scales may be administered in a fixed-length format only. Conclusions The SCI-QOL measurement system provides SCI researchers and clinicians with a comprehensive, relevant and psychometrically robust system for measurement of physical-medical, physical-functional, emotional, and social outcomes. All SCI-QOL instruments are freely available on Assessment CenterSM. PMID:26010963
NASA Astrophysics Data System (ADS)
Sánchez, Raquel; Cañabate, Águeda; Bresson, Carole; Chartier, Frédéric; Isnard, Hélène; Maestre, Salvador; Nonell, Anthony; Todolí, José-Luis
2017-03-01
This work describes for the first time the comparison of the analytical performances obtained with a high temperature torch integrated sample introduction system (hTISIS) against those found with a commercially available desolvation system (APEX) associated with inductively coupled plasma mass spectrometry (ICP-MS). A double pass spray chamber was taken as the reference system. Similar detection limits and sensitivities were obtained in continuous injection mode at low liquid flow rates for the APEX and hTISIS operating at high temperatures. In contrast, in the air-segmented injection mode, the detection limits obtained with hTISIS at high temperatures were up to 12 times lower than those found for the APEX. Regarding memory effects, wash out times were shorter in continuous mode and peaks were narrower in air segmented mode for the hTISIS as compared to the APEX. Non spectral interferences (matrix effects) were studied with 10% nitric acid, 2% methanol, for an ICP multielemental solution and a hydro-organic matrix containing 70% (v/v) acetonitrile in water, 15 mmol L- 1 ammonium acetate and 0.5% formic acid containing lanthanide complexes. In all the cases, matrix effects were less severe for the hTISIS operating at 200 °C and the APEX than for the double pass spray chamber. Finally, two spiked reference materials (sea water and Antartic krill) were analyzed. The hTISIS operating at 200 °C gave the best results compared to those obtained with the APEX and the double pass spray chamber. In conclusion, despite the simplicity of the hTISIS, it provided, at low liquid flow rates, results similar to or better than those obtained with the by other sample introduction systems.
Thompson, Sanna J.; Bender, Kimberly A.; Lewis, Carol M.; Watkins, Rita
2009-01-01
Purpose Homeless youth are at particularly high risk for teen pregnancy; research indicates as many as 20% of homeless young women become pregnant. These pregnant and homeless teens lack financial resources and adequate health care, resulting in increased risk for low– birth-weight babies and high infant mortality. This study investigated individual and family-level predictors of teen pregnancy among a national sample of runaway/homeless youth in order to better understand the needs of this vulnerable population. Methods Data from the Runaway/Homeless Youth Management Information System (RHY MIS) provided a national sample of youth seeking services at crisis shelters. A sub-sample of pregnant females and a random sub-sample (matched by age) of nonpregnant females comprised the study sample (N= 951). Chi-square and t tests identified differences between pregnant and nonpregnant runaway females; maximum likelihood logistic regression identified individual and family-level predictors of teen pregnancy. Results Teen pregnancy was associated with being an ethnic minority, dropping out of school, being away from home for longer periods of time, having a sexually transmitted disease, and feeling abandoned by one's family. Family factors, such as living in a single parent household and experiencing emotional abuse by one's mother, increased the odds of a teen being pregnant. Conclusions The complex problems associated with pregnant runaway/homeless teens create challenges for short-term shelter services. Suggestions are made for extending shelter services to include referrals and coordination with teen parenting programs and other systems of care. PMID:18639785
Epidemiological investigation of an outbreak of typhoid fever in Jorhat town of Assam, India
Roy, Jashbeer Singh; Saikia, Lahari; Medhi, Mithu; Tassa, Dipak
2016-01-01
Background & objectives: Typhoid fever is a global health problem and is also endemic in India. An outbreak of fever occurred in January 2014 in Jorhat Town in Assam, India. Here we report the results of an investigation done to find out the aetiology and source of the outbreak. Methods: The affected areas were visited on January 23, 2014 by a team of Jorhat district Integrated Disease Surveillance Project personnel. A total of 13 blood samples from patients with fever as first symptom and six water samples were collected from the affected areas. The blood samples were cultured and isolates were identified using standard biochemical tests. Isolates were also tested for antimicrobial sensitivity. Widal test was performed on 10 of the 13 blood samples collected. Sanitary survey was carried out to find any leakage in the water supply and also the sewage system of the Jorhat town. Results: Blood culture yielded Salmonella enterica serovar Typhi in six (46.15%) patients whereas Widal test was positive in 10 (76.9%) of 13 patients. Water culture showed presumptive coliform count of >180/100 ml in two out of the six samples tested. Salmonella Typhi was also isolated from water culture of these two samples. Sanitary survey carried out in the affected places showed that the water supply pipes of urban water supply were in close proximity to the sewage drainage system and there were few leakages. Interpretation & conclusions: The outbreak occurred due to S. Typhi contaminating the water supply. Sanitation and immunization are the two most important components to be stressed to prevent such outbreaks. PMID:28256469
Detection of illicit drugs with the technique of spectral fluorescence signatures (SFS)
NASA Astrophysics Data System (ADS)
Poryvkina, Larisa; Babichenko, Sergey
2010-10-01
The SFS technology has already proved its analytical capabilities in a variety of industrial and environmental tasks. Recently it has been introduced for forensic applications. The key features of the SFS method - measuring a 3-dimensional spectrum of fluorescence of the sample (intensity versus excitation and emission wavelengths) with following recognition of specific spectral patterns of SFS responsible for individual drugs - provide an effective tool for the analysis of untreated seized samples, without any separation of the substance of interest from its mixture with accompanying cutting agents and diluents as a preparatory step. In such approach the chemical analysis of the sample is substituted by the analysis of SFS matrix visualized as an optical image. The SFS technology of drug detection is realized by NarTest® NTX2000 analyzer, compact device intended to measure suspicious samples in liquid, solid and powder forms. It simplifies the detection process due to fully automated procedures of SFS measuring and integrated expert system for recognition of spectral patterns. Presently the expert system of NTX2000 is able to detect marijuana, cocaine, heroin, MDMA, amphetamine and methamphetamine with the detection limit down to 5% of the drug concentration in various mixtures. The numerous tests with street samples confirmed that the use of SFS method provides reliable results with high sensitivity and selectivity for identification of drugs of abuse. More than 3000 street samples of the aforesaid drugs were analyzed with NTX2000 during validation process, and the correspondence of SFS results and conclusions of standard forensic analyses with GC/MS techniques was in 99.4% cases.
Kertesz, Vilmos; Paranthaman, Nithya; Moench, Paul; ...
2014-10-01
The aim of this paper was to evaluate the analytical performance of a fully automated droplet-based surface-sampling system for determining the distribution of the drugs acetaminophen and terfenadine, and their metabolites, in rat thin tissue sections. The following are the results: The rank order of acetaminophen concentration observed in tissues was stomach > small intestine > liver, while the concentrations of its glucuronide and sulfate metabolites were greatest in the liver and small intestine. Terfenadine was most concentrated in the liver and kidney, while its major metabolite, fexofenadine, was found in the liver and small intestine. In conclusion, the spatialmore » distributions of both drugs and their respective metabolites observed in this work were consistent with previous studies using radiolabeled drugs.« less
Basco, M R; Birchler, G R; Kalal, B; Talbott, R; Slater, M A
1991-05-01
This paper reports the results of an initial investigation of the psychometric properties of a new clinical marital communication assessment instrument, the Clinician Rating of Adult Communication (CRAC). The sample consisted of 36 marital communication samples from both maritally satisfied and distressed couples. Reliability results indicated that the CRAC demonstrated high levels of internal consistency, test-retest reliability, and interrater agreement. Support for the validity of the CRAC was found in its correspondence with a marital interaction coding system, its relationship to ratings of marital satisfaction, and its concordance with couples' perceptions of their conflict management behavior. Overall, these findings support the conclusion that the CRAC may provide a useful addition to the measurement armamentarium of the marital clinician and researcher.
The Serological and Virological Investigation of Canine Adenovirus Infection on the Dogs
Bulut, Oya; Yapici, Orhan; Avci, Oguzhan; Simsek, Atilla; Atli, Kamil; Dik, Irmak; Yavru, Sibel; Hasircioglu, Sibel; Kale, Mehmet; Mamak, Nuri
2013-01-01
Two types of Canine Adenovirus (CAVs), Canine Adenovirus type 1 (CAV-1), the virus which causes infectious canine hepatitis, and Canine Adenovirus type 2 (CAV-2), which causes canine infectious laryngotracheitis, have been found in dogs. In this study, blood samples taken from 111 dogs, which were admitted to the Internal Medicine Clinic of Selcuk University, Faculty of Veterinary Medicine, with clinical symptoms. Seventy-seven dogs were sampled from Isparta and Burdur dog shelters by random sampling, regardless of the clinical findings. Dogs showed a systemic disease, characterized by fever, diarrhea, vomiting, oculonasal discharge, conjunctivitis, severe moist cough, signs of pulmonary disease and dehydration. Two dogs had corneal opacity and photophobia. In serological studies, 188 serum samples were investigated on the presence of CAV antibodies by ELISA. Total 103 (103/188–54.7%) blood samples were detected to be positive for CAV antibodies by ELISA. However, 85 (85/188–45.2%) blood samples were negative. Blood leukocyte samples from dogs were processed and inoculated onto confluent monolayers of MDCK cells using standard virological techniques. After third passage, cells were examined by direct immunoflourescence test for virus isolation. But positive result was not detected. In conclusion, this study clearly demonstrates the high prevalence of CAV infection in dogs. PMID:24223508
Hansen, Maj; Hyland, Philip; Karstoft, Karen-Inge; Vaegter, Henrik B.; Bramsen, Rikke H.; Nielsen, Anni B. S.; Armour, Cherie; Andersen, Søren B.; Høybye, Mette Terp; Larsen, Simone Kongshøj; Andersen, Tonny E.
2017-01-01
ABSTRACT Background: Researchers and clinicians within the field of trauma have to choose between different diagnostic descriptions of posttraumatic stress disorder (PTSD) in the DSM-5 and the proposed ICD-11. Several studies support different competing models of the PTSD structure according to both diagnostic systems; however, findings show that the choice of diagnostic systems can affect the estimated prevalence rates. Objectives: The present study aimed to investigate the potential impact of using a large (i.e. the DSM-5) compared to a small (i.e. the ICD-11) diagnostic description of PTSD. In other words, does the size of PTSD really matter? Methods: The aim was investigated by examining differences in diagnostic rates between the two diagnostic systems and independently examining the model fit of the competing DSM-5 and ICD-11 models of PTSD across three trauma samples: university students (N = 4213), chronic pain patients (N = 573), and military personnel (N = 118). Results: Diagnostic rates of PTSD were significantly lower according to the proposed ICD-11 criteria in the university sample, but no significant differences were found for chronic pain patients and military personnel. The proposed ICD-11 three-factor model provided the best fit of the tested ICD-11 models across all samples, whereas the DSM-5 seven-factor Hybrid model provided the best fit in the university and pain samples, and the DSM-5 six-factor Anhedonia model provided the best fit in the military sample of the tested DSM-5 models. Conclusions: The advantages and disadvantages of using a broad or narrow set of symptoms for PTSD can be debated, however, this study demonstrated that choice of diagnostic system may influence the estimated PTSD rates both qualitatively and quantitatively. In the current described diagnostic criteria only the ICD-11 model can reflect the configuration of symptoms satisfactorily. Thus, size does matter when assessing PTSD. PMID:29201287
Hansen, Maj; Hyland, Philip; Karstoft, Karen-Inge; Vaegter, Henrik B; Bramsen, Rikke H; Nielsen, Anni B S; Armour, Cherie; Andersen, Søren B; Høybye, Mette Terp; Larsen, Simone Kongshøj; Andersen, Tonny E
2017-01-01
Background : Researchers and clinicians within the field of trauma have to choose between different diagnostic descriptions of posttraumatic stress disorder (PTSD) in the DSM-5 and the proposed ICD-11. Several studies support different competing models of the PTSD structure according to both diagnostic systems; however, findings show that the choice of diagnostic systems can affect the estimated prevalence rates. Objectives : The present study aimed to investigate the potential impact of using a large (i.e. the DSM-5) compared to a small (i.e. the ICD-11) diagnostic description of PTSD. In other words, does the size of PTSD really matter? Methods: The aim was investigated by examining differences in diagnostic rates between the two diagnostic systems and independently examining the model fit of the competing DSM-5 and ICD-11 models of PTSD across three trauma samples: university students ( N = 4213), chronic pain patients ( N = 573), and military personnel ( N = 118). Results : Diagnostic rates of PTSD were significantly lower according to the proposed ICD-11 criteria in the university sample, but no significant differences were found for chronic pain patients and military personnel. The proposed ICD-11 three-factor model provided the best fit of the tested ICD-11 models across all samples, whereas the DSM-5 seven-factor Hybrid model provided the best fit in the university and pain samples, and the DSM-5 six-factor Anhedonia model provided the best fit in the military sample of the tested DSM-5 models. Conclusions : The advantages and disadvantages of using a broad or narrow set of symptoms for PTSD can be debated, however, this study demonstrated that choice of diagnostic system may influence the estimated PTSD rates both qualitatively and quantitatively. In the current described diagnostic criteria only the ICD-11 model can reflect the configuration of symptoms satisfactorily. Thus, size does matter when assessing PTSD.
Analysis of Wastewater for Organic Compounds Unique to RDX/HMX manufacturing and Processing
1979-12-01
Evaporation 6.. ............ 6 Analytical Separation’and Identification.• 6Gas Chromatography. 6 Liquid Chromatography ( LC )’and’Infrared Analyses (iR...steam-heated system. This conclusion was arrived at by comparing chromatograms relative to numbers of, and intensity of the component peaks . Analytical...for chromatographing the samples are listed below: (1) 10% UC-W-98 on Chrom G-AW-DMCS 0.61 m x 6.3 mm (2 ft. x ¼ in.) glass col umn (2) 10% UC-W-98 on
Interfacial oxide re-growth in thin film metal oxide III-V semiconductor systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDonnell, S.; Dong, H.; Hawkins, J. M.
2012-04-02
The Al{sub 2}O{sub 3}/GaAs and HfO{sub 2}/GaAs interfaces after atomic layer deposition are studied using in situ monochromatic x-ray photoelectron spectroscopy. Samples are deliberately exposed to atmospheric conditions and interfacial oxide re-growth is observed. The extent of this re-growth is found to depend on the dielectric material and the exposure temperature. Comparisons with previous studies show that ex situ characterization can result in misleading conclusions about the interface reactions occurring during the metal oxide deposition process.
Microbiome in the Apical Root Canal System of Teeth with Post-Treatment Apical Periodontitis
Siqueira, José F.; Antunes, Henrique S.; Rôças, Isabela N.; Rachid, Caio T. C. C.
2016-01-01
Introduction Bacteria present in the apical root canal system are directly involved with the pathogenesis of post-treatment apical periodontitis. This study used a next-generation sequencing approach to identify the bacterial taxa occurring in cryopulverized apical root samples from root canal-treated teeth with post-treatment disease. Methods Apical root specimens obtained during periradicular surgery of ten adequately treated teeth with persistent apical periodontitis were cryogenically ground. DNA was extracted from the powder and the microbiome was characterized on the basis of the V4 hypervariable region of the 16S rRNA gene by using paired-end sequencing on Illumina MiSeq device. Results All samples were positive for the presence of bacterial DNA. Bacterial taxa were mapped to 11 phyla and 103 genera composed by 538 distinct operational taxonomic units (OTUs) at 3% of dissimilarity. Over 85% of the sequences belonged to 4 phyla: Proteobacteria, Firmicutes, Fusobacteria and Actinobacteria. In general, these 4 phyla accounted for approximately 80% of the distinct OTUs found in the apical root samples. Proteobacteria was the most abundant phylum in 6/10 samples. Fourteen genera had representatives identified in all cases. Overall, the genera Fusobacterium and Pseudomonas were the most dominant. Enterococcus was found in 4 cases, always in relatively low abundance. Conclusions This study showed a highly complex bacterial community in the apical root canal system of adequately treated teeth with persistent apical periodontitis. This suggests that this disease is characterized by multispecies bacterial communities and has a heterogeneous etiology, because the community composition largely varied from case to case. PMID:27689802
Gassner, Christoph; Rainer, Esther; Pircher, Elfriede; Markut, Lydia; Körmöczi, Günther F.; Jungbauer, Christof; Wessin, Dietmar; Klinghofer, Roswitha; Schennach, Harald; Schwind, Peter; Schönitzer, Diether
2009-01-01
Summary Background Validations of routinely used serological typing methods require intense performance evaluations typically including large numbers of samples before routine application. However, such evaluations could be improved considering information about the frequency of standard blood groups and their variants. Methods Using RHD and ABO population genetic data, a Caucasian-specific donor panel was compiled for a performance comparison of the three RhD and ABO serological typing methods MDmulticard (Medion Diagnostics), ID-System (DiaMed) and ScanGel (Bio-Rad). The final test panel included standard and variant RHD and ABO genotypes, e.g. RhD categories, partial and weak RhDs, RhD DELs, and ABO samples, mainly to interpret weak serological reactivity for blood group A specificity. All samples were from individuals recorded in our local DNA blood group typing database. Results For ‘standard’ blood groups, results of performance were clearly interpretable for all three serological methods compared. However, when focusing on specific variant phenotypes, pronounced differences in reaction strengths and specificities were observed between them. Conclusions A genetically and ethnically predefined donor test panel consisting of 93 individual samples only, delivered highly significant results for serological performance comparisons. Such small panels offer impressive representative powers, higher as such based on statistical chances and large numbers only. PMID:21113264
Study of the ink-paper interaction by image analysis: surface and bulk inspection
NASA Astrophysics Data System (ADS)
Fiadeiro, Paulo T.; de O. Mendes, António; M. Ramos, Ana M.; L. de Sousa, Sónia C.
2013-11-01
In this work, two optical systems previously designed and implemented by our research team, were used to enable the surface and bulk inspection of the ink-paper interaction by image analysis. Basically, the first system works by ejecting micro-liter ink drops onto the papers surface while monitoring the event under three different views over time. The second system is used for sectioning the paper samples through their thickness and to simultaneously acquire images of the ink penetration of each section cut. In the performed experiments, three black inks of different brands and a common copy paper were chosen, used, and tested with the two developed optical systems. Both qualitative and quantitative analyses were carried out at the surface level and in the bulk of the paper. In terms of conclusions, it was shown that the three tested ink-paper combinations revealed very distinct characteristics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDonald, K; Curran, B
I. Information Security Background (Speaker = Kevin McDonald) Evolution of Medical Devices Living and Working in a Hostile Environment Attack Motivations Attack Vectors Simple Safety Strategies Medical Device Security in the News Medical Devices and Vendors Summary II. Keeping Radiation Oncology IT Systems Secure (Speaker = Bruce Curran) Hardware Security Double-lock Requirements “Foreign” computer systems Portable Device Encryption Patient Data Storage System Requirements Network Configuration Isolating Critical Devices Isolating Clinical Networks Remote Access Considerations Software Applications / Configuration Passwords / Screen Savers Restricted Services / access Software Configuration Restriction Use of DNS to restrict accesse. Patches / Upgrades Awareness Intrusionmore » Prevention Intrusion Detection Threat Risk Analysis Conclusion Learning Objectives: Understanding how Hospital IT Requirements affect Radiation Oncology IT Systems. Illustrating sample practices for hardware, network, and software security. Discussing implementation of good IT security practices in radiation oncology. Understand overall risk and threats scenario in a networked environment.« less
Preventable in-hospital medical injury under the "no fault" system in New Zealand
Davis, P; Lay-Yee, R; Briant, R; Scott, A
2003-01-01
Objectives: To describe the pattern of preventable in-hospital medical injury under the "no fault" system and to assess the level of serious preventable patient harm. Design: Cross sectional survey using a two stage retrospective assessment of medical records conducted by structured implicit review. Setting: General hospitals with over 100 beds providing acute care in New Zealand. Participants: A sample of 6579 patients admitted in 1998 to 13 hospitals selected by stratified systematic list sample. Main outcome measures: Occurrence, preventability, and impact of adverse events. Results: Over 5% of admissions were associated with a preventable in-hospital event, of which nearly half had an element of systems failure. The elderly, ethnic minority groups, and particular clinical areas were at higher risk. The chances of a patient experiencing a serious preventable adverse event subsequent to hospital admission were just under 1%, a figure close to published results from comparable studies under tort. On average, these events required an additional 4 weeks in hospital. System related issues of protocol use and development, communication, and organisation, as well as requirements for consultation and education, were pre-eminent. Conclusions: The risk of serious preventable in-hospital medical injury for patients in New Zealand, a well established "no fault" jurisdiction, is within the range reported in comparable investigations under tort. PMID:12897357
Anderson, Ruth A.; Hsieh, Pi-Ching; Su, Hui Fang; Landerman, Lawrence R.; McDaniel, Reuben R.
2013-01-01
Objectives. To (1) describe participation in decision-making as a systems-level property of complex adaptive systems and (2) present empirical evidence of reliability and validity of a corresponding measure. Method. Study 1 was a mail survey of a single respondent (administrators or directors of nursing) in each of 197 nursing homes. Study 2 was a field study using random, proportionally stratified sampling procedure that included 195 organizations with 3,968 respondents. Analysis. In Study 1, we analyzed the data to reduce the number of scale items and establish initial reliability and validity. In Study 2, we strengthened the psychometric test using a large sample. Results. Results demonstrated validity and reliability of the participation in decision-making instrument (PDMI) while measuring participation of workers in two distinct job categories (RNs and CNAs). We established reliability at the organizational level aggregated items scores. We established validity of the multidimensional properties using convergent and discriminant validity and confirmatory factor analysis. Conclusions. Participation in decision making, when modeled as a systems-level property of organization, has multiple dimensions and is more complex than is being traditionally measured. Managers can use this model to form decision teams that maximize the depth and breadth of expertise needed and to foster connection among them. PMID:24349771
Laser Altimetry Sampling Strategies over Sea Ice
NASA Technical Reports Server (NTRS)
Farrell, Sinead L.; Markus, Thorsten; Kwok, Ron; Connor, Laurence
2011-01-01
With the conclusion of the science phase of the Ice, Cloud and land Elevation Satellite (ICESat) mission in late 2009, and the planned launch of ICESat-2 in late 2015, NASA has recently established the IceBridge program to provide continuity between missions. A major goal of IceBridge is to obtain a sea-ice thickness time series via airborne surveys over the Arctic and Southern Oceans. Typically two laser altimeters, the Airborne Topographic Mapper (ATM) and the Land, Vegetation and Ice Sensor (LVIS), are utilized during IceBridge flights. Using laser altimetry simulations of conventional analogue systems such as ICESat, LVIS and ATM, with the multi-beam system proposed for ICESat-2, we investigate differences in measurements gathered at varying spatial resolutions and the impact on sea-ice freeboard. We assess the ability of each system to reproduce the elevation distributions of two seaice models and discuss potential biases in lead detection and sea-surface elevation, arising from variable footprint size and spacing. The conventional systems accurately reproduce mean freeboard over 25km length scales, while ICESat-2 offers considerable improvements over its predecessor ICESat. In particular, its dense along-track sampling of the surface will allow flexibility in the algorithmic approaches taken to optimize the signal-to-noise ratio for accurate and precise freeboard retrieval.
HETEROGENEITY OF SYSTEMIC INFLAMMATORY RESPONSES TO PERIODONTAL THERAPY
Behle, Jan H.; Sedaghatfar, Michael H.; Demmer, Ryan T.; Wolf, Dana L.; Celenti, Romanita; Kebschull, Moritz; Belusko, Paul B.; Herrera-Abreu, Miriam; Lalla, Evanthia; Papapanou, Panos N.
2009-01-01
Aims We investigated the effect of comprehensive periodontal therapy on the levels of multiple systemic inflammatory biomarkers. Methods Thirty patients with severe periodontitis received comprehensive periodontal therapy within a 6-week period. Blood samples were obtained at: one week pre- therapy (T1), therapy initiation (T2), treatment completion (T3), and 4 weeks thereafter (T4). We assessed plasma concentrations of 19 biomarkers using multiplex assays, and serum IgG antibodies to periodontal bacteria using checkerboard immunoblotting. At T2 and T4, dental plaque samples were analyzed using checkerboard hybridizations. Results At T3, PAI-1, sE-selectin, sVCAM-1, MMP-9, myeloperoxidase, and a composite Summary Inflammatory Score (SIS) were significantly reduced. However, only sE-selectin, sICAM, and serum amyloid P sustained a reduction at T4. Responses were highly variable: analyses of SIS slopes between baseline and T4 showed that approximately 1/3 and 1/4 of the patients experienced marked reduction and pronounced increase in systemic inflammation, respectively, while the remainder were seemingly unchanged. Changes in inflammatory markers correlated poorly with clinical, microbiological and serological markers of periodontitis. Conclusions Periodontal therapy resulted in an overall reduction of systemic inflammation, but the responses were inconsistent across subjects and largely not sustainable. The determinants of this substantial heterogeneity need to be explored further. PMID:19426174
Development and Characterization of a Parallelizable Perfusion Bioreactor for 3D Cell Culture.
Egger, Dominik; Fischer, Monica; Clementi, Andreas; Ribitsch, Volker; Hansmann, Jan; Kasper, Cornelia
2017-05-25
The three dimensional (3D) cultivation of stem cells in dynamic bioreactor systems is essential in the context of regenerative medicine. Still, there is a lack of bioreactor systems that allow the cultivation of multiple independent samples under different conditions while ensuring comprehensive control over the mechanical environment. Therefore, we developed a miniaturized, parallelizable perfusion bioreactor system with two different bioreactor chambers. Pressure sensors were also implemented to determine the permeability of biomaterials which allows us to approximate the shear stress conditions. To characterize the flow velocity and shear stress profile of a porous scaffold in both bioreactor chambers, a computational fluid dynamics analysis was performed. Furthermore, the mixing behavior was characterized by acquisition of the residence time distributions. Finally, the effects of the different flow and shear stress profiles of the bioreactor chambers on osteogenic differentiation of human mesenchymal stem cells were evaluated in a proof of concept study. In conclusion, the data from computational fluid dynamics and shear stress calculations were found to be predictable for relative comparison of the bioreactor geometries, but not for final determination of the optimal flow rate. However, we suggest that the system is beneficial for parallel dynamic cultivation of multiple samples for 3D cell culture processes.
Development and Characterization of a Parallelizable Perfusion Bioreactor for 3D Cell Culture
Egger, Dominik; Fischer, Monica; Clementi, Andreas; Ribitsch, Volker; Hansmann, Jan; Kasper, Cornelia
2017-01-01
The three dimensional (3D) cultivation of stem cells in dynamic bioreactor systems is essential in the context of regenerative medicine. Still, there is a lack of bioreactor systems that allow the cultivation of multiple independent samples under different conditions while ensuring comprehensive control over the mechanical environment. Therefore, we developed a miniaturized, parallelizable perfusion bioreactor system with two different bioreactor chambers. Pressure sensors were also implemented to determine the permeability of biomaterials which allows us to approximate the shear stress conditions. To characterize the flow velocity and shear stress profile of a porous scaffold in both bioreactor chambers, a computational fluid dynamics analysis was performed. Furthermore, the mixing behavior was characterized by acquisition of the residence time distributions. Finally, the effects of the different flow and shear stress profiles of the bioreactor chambers on osteogenic differentiation of human mesenchymal stem cells were evaluated in a proof of concept study. In conclusion, the data from computational fluid dynamics and shear stress calculations were found to be predictable for relative comparison of the bioreactor geometries, but not for final determination of the optimal flow rate. However, we suggest that the system is beneficial for parallel dynamic cultivation of multiple samples for 3D cell culture processes. PMID:28952530
Anderson, Ruth A; Plowman, Donde; Corazzini, Kirsten; Hsieh, Pi-Ching; Su, Hui Fang; Landerman, Lawrence R; McDaniel, Reuben R
2013-01-01
Objectives. To (1) describe participation in decision-making as a systems-level property of complex adaptive systems and (2) present empirical evidence of reliability and validity of a corresponding measure. Method. Study 1 was a mail survey of a single respondent (administrators or directors of nursing) in each of 197 nursing homes. Study 2 was a field study using random, proportionally stratified sampling procedure that included 195 organizations with 3,968 respondents. Analysis. In Study 1, we analyzed the data to reduce the number of scale items and establish initial reliability and validity. In Study 2, we strengthened the psychometric test using a large sample. Results. Results demonstrated validity and reliability of the participation in decision-making instrument (PDMI) while measuring participation of workers in two distinct job categories (RNs and CNAs). We established reliability at the organizational level aggregated items scores. We established validity of the multidimensional properties using convergent and discriminant validity and confirmatory factor analysis. Conclusions. Participation in decision making, when modeled as a systems-level property of organization, has multiple dimensions and is more complex than is being traditionally measured. Managers can use this model to form decision teams that maximize the depth and breadth of expertise needed and to foster connection among them.
Development of a refrigeration system for lunar surface and spacecraft applications
NASA Technical Reports Server (NTRS)
Copeland, R. J.
1976-01-01
An evaluation of refrigeration devices suitable for potential lunar surface and spacecraft applications was performed. The following conclusions were reached: (1) the vapor compression system is the best overall refrigeration system for lunar surface and spacecraft applications and the single phase radiator system is generally preferred for earth orbit applications, (2) the vapor compression cycle may have some application for simultaneous heating and cooling, (3) a Stirling cycle refrigerator was selected for the manned cabin of the space shuttle, and (4) significant increases in payload heat rejection can be obtained by a kit vapor compression refrigerator added to the shuttle R-21 loop. The following recommendations were made: (1) a Stirling cycle refrigerator may be used for food freezer and biomedical sample storage, (2) the best system for a food freezer/experiments compartment for an earth orbit space station has not been determined, (3) a deployed radiator system can be designed for large heat loads in earth orbit.
Study of the most frequent natural tooth colors in the Spanish population using spectrophotometry
2015-01-01
PURPOSE To identify the most frequent natural tooth colors using the Easyshade Compact (Vita -Zahnfabrik) spectrophotometer on a sample of the Spanish population according to the 3D Master System. MATERIALS AND METHODS The middle third of the facial surface of natural maxillary central incisors was measured with an Easyshade Compact spectrophotometer (Vita Zahnfabrik) in 1361 Caucasian Spanish participants aged between 16 and 89 years. Natural tooth color was recorded using the 3D Master System nomenclature. The program used for the present descriptive statistical analysis of the results was SAS 9.1.3. RESULTS The results show that the most frequent dental color in the total sample studied is 3M1 (7.05%), followed by the intermediate shade 1M1.5 (6.91%) and 2L1.5 (6.02%). CONCLUSION According to the research methodology used, and taking into account the limitations of this study, it can be proposed that the most frequent color among the Spanish population is 3M1; the most common lightness group is 2; the most frequent hue group according to the 3D Master System is M and the most frequent chroma group is 1.5. PMID:26816571
NASA Astrophysics Data System (ADS)
Korshak, V. F.; Chushkina, R. A.; Shapovalov, Yu. A.; Mateichenko, P. V.
2011-07-01
Samples of a Bi-43 wt % Sn superplastic alloy have been studied by X-ray diffraction in the ascast state, after compression of as-cast samples to ˜70% on a hydraulic press, after aging in the as-cast and preliminarily compressed state, and using samples deformed under superplastic conditions. The X-ray diffraction studies have been carried out using a DRON-2.0 diffractometer in Cu Kα radiation. The samples aged and deformed under superplasticity conditions have been studied using electron-microprobe analysis in a JSM-820 scanning electron microscope equipped with a LINK AN/85S EDX system. It has been found that the initial structural-phase state of the alloy was amorphous-crystalline. Causes that lead to a change in this state upon deformation and aging are discussed. A conclusion is made that the superplasticity effect manifests itself against the background of processes that are stipulated by the tendency of the initially metastable alloy to phase equilibrium similarly to what is observed in the Sn-38 wt % Pb eutectic alloy studied earlier.
Patient Accounting Systems: Are They Fit with the Users' Requirements?
Ayatollahi, Haleh; Nazemi, Zahra
2016-01-01
Objectives A patient accounting system is a subsystem of a hospital information system. This system like other information systems should be carefully designed to be able to meet users' requirements. The main aim of this research was to investigate users' requirements and to determine whether current patient accounting systems meet users' needs or not. Methods This was a survey study, and the participants were the users of six patient accounting systems used in 24 teaching hospitals. A stratified sampling method was used to select the participants (n = 216). The research instruments were a questionnaire and a checklist. The mean value of ≥3 showed the importance of each data element and the capability of the system. Results Generally, the findings showed that the current patient accounting systems had some weaknesses and were able to meet between 70% and 80% of users' requirements. Conclusions The current patient accounting systems need to be improved to be able to meet users' requirements. This approach can also help to provide hospitals with more usable and reliable financial information. PMID:26893945
SE33 locus as a reliable genetic marker for forensic DNA analysis systems
Bhinder, Munir Ahmad; Zahoor, Muhammad Yasir; Sadia, Haleema; Qasim, Muhammad; Perveen, Rukhsana; Anjum, Ghulam Murtaza; Iqbal, Muhammad; Ullah, Najeeb; Shehzad, Wasim; Tariq, Muhammad; Waryah, Ali Muhammad
2018-06-14
Background/aim: Genetic variation, an authentic tool of individual discrimination, is being used for forensic investigations worldwide. A missing result for even one out of 13-17 markers leads to an inconclusive report. Additional reliable markers are required to compensate such deficiencies. The SE33 locus has high genetic variability in different populations and is being used in forensic investigation systems in some countries. The purpose of the study was to assess the viability of use of the SE33 locus as a supportive marker for forensic DNA profiling. Materials and methods: Amplification of the SE33 locus was performed using the PowerPlex ES Monoplex System SE33 (Promega). After genotyping 204 Pakistani individuals, different genetic and forensic parameters for the SE33 locus were studied. Results: Genotyping of the SE33 locus revealed a total of 43 alleles including 3 novel alleles. Significant values of different forensic and genetic parameters including power of discrimination, power of exclusion, and polymorphism information content were observed. Conclusions: Addition of the SE33 locus in forensic DNA profiling may help to produce conclusive reports where results are inconclusive due to degraded evidence samples. The SE33 locus can confidently be used for Pakistani and neighboring populations having common ancestors from Iran to Central Asia, the Middle East, India and Turkey.
Solimini, Angelo G.
2013-01-01
Background The increasing popularity of commercial movies showing three dimensional (3D) images has raised concern about possible adverse side effects on viewers. Methods and Findings A prospective carryover observational study was designed to assess the effect of exposure (3D vs. 2D movie views) on self reported symptoms of visually induced motion sickness. The standardized Simulator Sickness Questionnaire (SSQ) was self administered on a convenience sample of 497 healthy adult volunteers before and after the vision of 2D and 3D movies. Viewers reporting some sickness (SSQ total score>15) were 54.8% of the total sample after the 3D movie compared to 14.1% of total sample after the 2D movie. Symptom intensity was 8.8 times higher than baseline after exposure to 3D movie (compared to the increase of 2 times the baseline after the 2D movie). Multivariate modeling of visually induced motion sickness as response variables pointed out the significant effects of exposure to 3D movie, history of car sickness and headache, after adjusting for gender, age, self reported anxiety level, attention to the movie and show time. Conclusions Seeing 3D movies can increase rating of symptoms of nausea, oculomotor and disorientation, especially in women with susceptible visual-vestibular system. Confirmatory studies which include examination of clinical signs on viewers are needed to pursue a conclusive evidence on the 3D vision effects on spectators. PMID:23418530
NASA Astrophysics Data System (ADS)
Moriarty, John; Ballard, Sarah
2016-11-01
NASA’s Kepler Mission uncovered a wealth of planetary systems, many with planets on short-period orbits. These short-period systems reside around 50% of Sun-like stars and are similarly prevalent around M dwarfs. Their formation and subsequent evolution is the subject of active debate. In this paper, we simulate late-stage, in situ planet formation across a grid of planetesimal disks with varying surface density profiles and total mass. We compare simulation results with observable characteristics of the Kepler sample. We identify mixture models with different primordial planetesimal disk properties that self-consistently recover the multiplicity, radius, period and period ratio, and duration ratio distributions of the Kepler planets. We draw three main conclusions. (1) We favor a “frozen-in” narrative for systems of short-period planets, in which they are stable over long timescales, as opposed to metastable. (2) The “Kepler dichotomy,” an observed phenomenon of the Kepler sample wherein the architectures of planetary systems appear to either vary significantly or have multiple modes, can naturally be explained by formation within planetesimal disks with varying surface density profiles. Finally, (3) we quantify the nature of the “Kepler dichotomy” for both GK stars and M dwarfs, and find that it varies with stellar type. While the mode of planet formation that accounts for high multiplicity systems occurs in 24% ± 7% of planetary systems orbiting GK stars, it occurs in 63% ± 16% of planetary systems orbiting M dwarfs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, R; Baer, E; Jee, K
Purpose: For proton therapy, an accurate model of CT HU to relative stopping power (RSP) conversion is essential. In current practice, validation of these models relies solely on measurements of tissue substitutes with standard compositions. Validation based on real tissue samples would be much more direct and can address variations between patients. This study intends to develop an efficient and accurate system based on the concept of dose extinction to measure WEPL and retrieve RSP in biological tissue in large number of types. Methods: A broad AP proton beam delivering a spread out Bragg peak (SOBP) is used to irradiatemore » the samples with a Matrixx detector positioned immediately below. A water tank was placed on top of the samples, with the water level controllable in sub-millimeter by a remotely controlled dosing pump. While gradually lowering the water level with beam on, the transmission dose was recorded at 1 frame/sec. The WEPL were determined as the difference between the known beam range of the delivered SOBP (80%) and the water level corresponding to 80% of measured dose profiles in time. A Gammex 467 phantom was used to test the system and various types of biological tissue was measured. Results: RSP for all Gammex inserts, expect the one made with lung-450 material (<2% error), were determined within ±0.5% error. Depends on the WEPL of investigated phantom, a measurement takes around 10 min, which can be accelerated by a faster pump. Conclusion: Based on the concept of dose extinction, a system was explored to measure WEPL efficiently and accurately for a large number of samples. This allows the validation of CT HU to stopping power conversions based on large number of samples and real tissues. It also allows the assessment of beam uncertainties due to variations over patients, which issue has never been sufficiently studied before.« less
Maintenance of head and neck tumor on-chip: gateway to personalized treatment?
Bower, Ruth; Green, Victoria L; Kuvshinova, Elena; Kuvshinov, Dmitriy; Karsai, Laszlo; Crank, Stephen T; Stafford, Nicholas D; Greenman, John
2017-01-01
Aim: Head and neck squamous cell carcinomas (HNSCC) are solid tumors with low overall survival (40–60%). In a move toward personalized medicine, maintenance of tumor biopsies in microfluidic tissue culture devices is being developed. Methodology/results: HNSCC (n = 15) was dissected (5–10 mg) and either analyzed immediately or cultured in a microfluidic device (37°C) for 48 h. No difference was observed in morphology between pre- and postculture specimens. Dissociated samples were analyzed using trypan blue exclusion (viability), propidium iodide flow cytometry (death) and MTS assay (proliferation) with no significant difference observed highlighting tissue maintenance. Computational fluid dynamics showed laminar flow within the system. Conclusion: The microfluidic culture system successfully maintained HNSCC for 48 h, the culture system will allow testing of different treatment modalities with response monitoring. PMID:28670466
ESTIMATING SYSTEMIC EXPOSURE TO ETHINYL ESTRADIOL FROM AN ORAL CONTRACEPTIVE
WESTHOFF, Carolyn L.; PIKE, Malcolm C.; TANG, Rosalind; DINAPOLI, Marianne N.; SULL, Monica; CREMERS, Serge
2015-01-01
Objectives This study was conducted to compare single-dose pharmacokinetics of ethinyl estradiol in an oral contraceptive to steady-state values, and to assess whether any simpler measures could provide an adequate proxy of the ‘gold standard’ 24-hour steady-state area-under-the-curve. Identifying a simple, less expensive, measure of systemic ethinyl estradiol exposure would be useful for larger studies designed to assess the relationship between an individual’s ethinyl estradiol exposure and her side effects. Study Design We conducted a 13 samples over 24 hours pharmacokinetic analysis on day 1 and day 21 of the first cycle of a monophasic oral contraceptive containing 30 mcg ethinyl estradiol and 150 mcg levonorgestrel in 17 non-obese healthy white women. We also conducted an abbreviated single dose 9-sample pharmacokinetic analysis after a month washout. Ethinyl estradiol was measured by liquid chromatography-tandem mass spectrometry. We compared results of full 13-sample steady-state pharmacokinetic analysis with results calculated using fewer samples (9 or 5) and following the single doses. We calculated Pearson correlation coefficients to evaluate the relationships between these estimates of systemic ethinyl estradiol exposure. Results The area-under-the-curve, maximum (Cmax), and 24-hour (C24) values were similar following the two single oral contraceptive doses (area-under-the-curve, r = 0.92). The steady-state 13-sample 24-hour area-under-the-curve was highly correlated with the average 9-sample area-under-the-curve after the two single doses (r = 0.81, p = 0.0002). This correlation remained the same if the number of samples was reduced to 4, taken at time 1, 2.5, 4 and 24 hours. The C24 at steady-state was highly correlated with the 24-hour steady-state area-under-the-curve (r = 0.92, p < 0.0001). The average of the C24 values following the two single doses was also quite highly correlated with the steady-state area-under-the-curve (r = 0.72, p = 0.0026). Conclusions Limited blood sampling, including results from two single doses, gave highly correlated estimates of an oral contraceptive user’s steady-state ethinyl estradiol exposure. PMID:25511238
Is a pre-analytical process for urinalysis required?
Petit, Morgane; Beaudeux, Jean-Louis; Majoux, Sandrine; Hennequin, Carole
2017-10-01
For the reliable urinary measurement of calcium, phosphate and uric acid, a pre-analytical process by adding acid or base to urine samples at laboratory is recommended in order to dissolve precipitated solutes. Several studies on different kind of samples and analysers have previously shown that a such pre-analytical treatment is useless. The objective was to study the necessity of pre-analytical treatment of urine on samples collected using the V-Monovette ® (Sarstedt) system and measured on the analyser Architect C16000 (Abbott Diagnostics). Sixty urinary samples of hospitalized patients were selected (n=30 for calcium and phosphate, and n=30 for uric acid). After acidification of urine samples for measurement of calcium and phosphate, and alkalinisation for measurement of uric acid respectively, differences between results before and after the pre-analytical treatment were compared to acceptable limits recommended by the French society of clinical biology (SFBC). No difference in concentration between before and after pre-analytical treatment of urine samples exceeded acceptable limits from SFBC for measurement of calcium and uric acid. For phosphate, only one sample exceeded these acceptable limits, showing a result paradoxically lower after acidification. In conclusion, in agreement with previous study, our results show that acidification or alkalinisation of urine samples from 24 h urines or from urination is not a pre-analytical necessity for measurement of calcium, phosphate and uric acid.
[Determining social factors related to pesticide poisoning among rice farmers in Colombia].
Varona, Marcela E; Díaz, Sonia M; Briceño, Leonardo; Sánchez-Infante, Clara I; Torres, Carlos H; Palma, Ruth M; Groot, Helena; Idrovo, Alvaro J
2016-08-01
Objective Large quantities of pesticides are used in rice crops. The aim of this study is to characterize how farmers are exposed to pesticides and subsequent poisoning. Materials and Methods A multilevel (individual and community) multi-method study, which included ethnographic and survey methods, as well as measurement of pesticides in water and human samples, was performed. Results The production process is described and the main risk factors are presented. Pesticides are considered the greatest danger at work and at their homes. Workers have poor working conditions and are not protected by the system of occupational risks. Azinphos-methyl, endosulfan, β-BHC, bromophos-methyl, bromophos-ethyl and 2,4- DDT were found in water samples. The survey included 381 workers with mild (12.86 %), moderate (67.98 %) and severe (5.51 %) poisonings respectively. Severe cases presented lower levels of education, lower levels of health care access to the contributory regimen of the Colombian social security system and higher incidence of cardiovascular disease, diabetes, herpes or other viral infections. Conclusion There are precarious working conditions that favor exposure to pesticides correlated to the exclusion of farmers from the occupational risk system, to poverty and to poor education. It is urgent to include these workers to the system of occupational risk system and to improve their living conditions, thus reducing unsafe practices when handling pesticides.
Sabattini, E; Bisgaard, K; Ascani, S; Poggi, S; Piccioli, M; Ceccarelli, C; Pieri, F; Fraternali-Orcioni, G; Pileri, S A
1998-01-01
AIM: To assess a newly developed immunohistochemical detection system, the EnVision++. METHODS: A large series of differently processed normal and pathological samples and 53 relevant monoclonal antibodies were chosen. A chessboard titration assay was used to compare the results provided by the EnVision++ system with those of the APAAP, CSA, LSAB, SABC, and ChemMate methods, when applied either manually or in a TechMate 500 immunostainer. RESULTS: With the vast majority of the antibodies, EnVision++ allowed two- to fivefold higher dilutions than the APAAP, LSAB, SABC, and ChemMate techniques, the staining intensity and percentage of expected positive cells being the same. With some critical antibodies (such as the anti-CD5), it turned out to be superior in that it achieved consistently reproducible results with differently fixed or overfixed samples. Only the CSA method, which includes tyramide based enhancement, allowed the same dilutions as the EnVision++ system, and in one instance (with the anti-cyclin D1 antibody) represented the gold standard. CONCLUSIONS: The EnVision++ is an easy to use system, which avoids the possibility of disturbing endogenous biotin and lowers the cost per test by increasing the dilutions of the primary antibodies. Being a two step procedure, it reduces both the assay time and the workload. Images PMID:9797726
Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Luo, Yunbo; Xu, Wentao
2016-03-18
Digital polymerase chain reaction (PCR) has developed rapidly since it was first reported in the 1990s. However, pretreatments are often required during preparation for digital PCR, which can increase operation error. The single-plex amplification of both the target and reference genes may cause uncertainties due to the different reaction volumes and the matrix effect. In the current study, a quantitative detection system based on the pretreatment-free duplex chamber digital PCR was developed. The dynamic range, limit of quantitation (LOQ), sensitivity and specificity were evaluated taking the GA21 event as the experimental object. Moreover, to determine the factors that may influence the stability of the duplex system, we evaluated whether the pretreatments, the primary and secondary structures of the probes and the SNP effect influence the detection. The results showed that the LOQ was 0.5% and the sensitivity was 0.1%. We also found that genome digestion and single nucleotide polymorphism (SNP) sites affect the detection results, whereas the unspecific hybridization within different probes had little side effect. This indicated that the detection system was suited for both chamber-based and droplet-based digital PCR. In conclusion, we have provided a simple and flexible way of achieving absolute quantitation for genetically modified organism (GMO) genome samples using commercial digital PCR detection systems.
Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Luo, Yunbo; Xu, Wentao
2016-01-01
Digital polymerase chain reaction (PCR) has developed rapidly since it was first reported in the 1990s. However, pretreatments are often required during preparation for digital PCR, which can increase operation error. The single-plex amplification of both the target and reference genes may cause uncertainties due to the different reaction volumes and the matrix effect. In the current study, a quantitative detection system based on the pretreatment-free duplex chamber digital PCR was developed. The dynamic range, limit of quantitation (LOQ), sensitivity and specificity were evaluated taking the GA21 event as the experimental object. Moreover, to determine the factors that may influence the stability of the duplex system, we evaluated whether the pretreatments, the primary and secondary structures of the probes and the SNP effect influence the detection. The results showed that the LOQ was 0.5% and the sensitivity was 0.1%. We also found that genome digestion and single nucleotide polymorphism (SNP) sites affect the detection results, whereas the unspecific hybridization within different probes had little side effect. This indicated that the detection system was suited for both chamber-based and droplet-based digital PCR. In conclusion, we have provided a simple and flexible way of achieving absolute quantitation for genetically modified organism (GMO) genome samples using commercial digital PCR detection systems. PMID:26999129
The ARAMIS project: a concept robot and technical design.
Colizzi, Lucio; Lidonnici, Antonio; Pignolo, Loris
2009-11-01
To describe the ARAMIS (Automatic Recovery Arm Motility Integrated System) project, a concept robot applicable in the neuro-rehabilitation of the paretic upper limb after stroke. Methods, results and conclusion: The rationale and engineering of a state-of-the-art, hardware/software integrated robot system, its mechanics, ergonomics, electric/electronics features providing control, safety and suitability of use are described. An ARAMIS prototype has been built and is now available for clinical tests. It allows the therapist to design neuro-rehabilitative (synchronous or asynchronous) training protocols in which sample exercises are generated by a single exoskeleton (operated by the patient's unaffected arm or by the therapist's arm) and mirrored in real-time or offline by the exoskeleton supporting the paretic arm.
Berlyne, Sigal; Oz, Carla; Einot, Naftaly; Avraham, Shlomit; Ram, Tanya; Goldberg, Miri D; Gafny, Ron
2017-07-01
In 2012 the Israel Police DNA Casework laboratory adopted the 16 STR PowerPlex ® ESI kit for routine use. The Promega Company updated this kit and developed the PowerPlex ® ESI 16 Fast System in which all autosomal primer pairs remained identical to the original set, except at the amelogenin site. The master mix was improved and optimized which allowed for direct, faster and more robust amplification. Prior to implementing the PowerPlex ® ESI 16 Fast System in our lab, we conducted a preliminary assay where 213 casework samples were amplified using the new kit. These samples had previously been extracted by one of two extraction kits employed by our lab. (the PrepFiler ExpressTM and PrepFiler BTATM Forensic DNA Extraction Kits). The amplification results from these samples were compared to samples amplified using the original PowerPlex ® ESI 16 kit. Multiple incidents of failure to amplify at the amelogenin locus were noted using the new system with the recommended protocol at a rate of 13% (28 of 213 samples). Experiments were performed to understand whether these amplification failures could be a result of primer binding site mutations, extraction method reagents and/or inhibitors. The conclusions reached following these experiments, in conjunction with consultation with the manufacturer, led to the trial of a modified amplification protocol where the suggested annealing temperature was reduced by 2 degrees. To evaluate the efficiency of this altered protocol, a comparison study was undertaken where 88 additional casework samples were chosen and amplified using both the modified 58°C and the recommended 60°C annealing temperatures. We concluded that the most effective method in our laboratory for achieving a consistent and balanced amplification at the amelogenin locus was to reduce the annealing temperature from the manufacturer's recommended 60°C to 58°C. This modification resulted in a reduction of the failure to amplify at the amelogenin locus from 13% (28/213) to 1.1% (1/88) without any observed changes to the autosomal STR amplification results. Copyright © 2017 Elsevier B.V. All rights reserved.
Westen, Drew; Shedler, Jonathan; Bradley, Bekh; DeFife, Jared A.
2013-01-01
Objective The authors describe a system for diagnosing personality pathology that is empirically derived, clinically relevant, and practical for day-to-day use. Method A random national sample of psychiatrists and clinical psychologists (N=1,201) described a randomly selected current patient with any degree of personality dysfunction (from minimal to severe) using the descriptors in the Shedler-Westen Assessment Procedure–II and completed additional research forms. Results The authors applied factor analysis to identify naturally occurring diagnostic groupings within the patient sample. The analysis yielded 10 clinically coherent personality diagnoses organized into three higher-order clusters: internalizing, externalizing, and borderline-dysregulated. The authors selected the most highly rated descriptors to construct a diagnostic prototype for each personality syndrome. In a second, independent sample, research interviewers and patients’ treating clinicians were able to diagnose the personality syndromes with high agreement and minimal comorbidity among diagnoses. Conclusions The empirically derived personality prototypes described here provide a framework for personality diagnosis that is both empirically based and clinically relevant. PMID:22193534
Preliminary Surface Thermal Design of the Mars 2020 Rover
NASA Technical Reports Server (NTRS)
Novak, Keith S.; Kempenaar, Jason G.; Redmond, Matthew J.; Bhandari, Pradeep
2015-01-01
The Mars 2020 rover, scheduled for launch in July 2020, is currently being designed at NASA's Jet Propulsion Laboratory. The Mars 2020 rover design is derived from the Mars Science Laboratory (MSL) rover, Curiosity, which has been exploring the surface of Mars in Gale Crater for over 2.5 years. The Mars 2020 rover will carry a new science payload made up of 7 instruments. In addition, the Mars 2020 rover is responsible for collecting a sample cache of Mars regolith and rock core samples that could be returned to Earth in a future mission. Accommodation of the new payload and the Sampling Caching System (SCS) has driven significant thermal design changes from the original MSL rover design. This paper describes the similarities and differences between the heritage MSL rover thermal design and the new Mars 2020 thermal design. Modifications to the MSL rover thermal design that were made to accommodate the new payload and SCS are discussed. Conclusions about thermal design flexibility are derived from the Mars 2020 preliminary thermal design experience.
Magnetization and photomagnetic effects in diluted magnetic microcrystalline Cd 1-xMn xTe
NASA Astrophysics Data System (ADS)
He, X.-F.; Kotlicki, A.; Dosanjh, P.; Turrell, B. G.; Carolan, J. F.; Jimenez-Sandoval, S.; Lozano-Tovar, P.
1993-12-01
We have investigated the magnetic and photomagnetic properties of microcrystalline Cd 1-xMn xTe prepared by rf sputtering. Magnetization measurements were carried out using an rf SQUID magnetometer in the temperature range of 1.8 to 300 K at various magnetic fields up to 5.5 T. For temperatures above 40 K, the sample showed Curie-Weiss behaviour with a Curie temperature indicating predominantly antiferromagnetic interactions. A spin-glass phase transition was also observed. Photomagnetization measurements were performed using a fibre-optic system. The light was shone onto the sample utilizing an optical fibre and the subsequent change in the magnetization was sensed by the SQUID. Photo-induced magnetization was observed when the sample was illuminated by unpolarized light. Our results enable qualitative and quantitative conclusions to be drawn on the magnetic behaviour and the interplay between optical and magnetic properties of the diluted magnetic microcrystalline semiconductors. PACS: 68.55.Gi; 75.50.Pp.
Confidence limit calculation for antidotal potency ratio derived from lethal dose 50
Manage, Ananda; Petrikovics, Ilona
2013-01-01
AIM: To describe confidence interval calculation for antidotal potency ratios using bootstrap method. METHODS: We can easily adapt the nonparametric bootstrap method which was invented by Efron to construct confidence intervals in such situations like this. The bootstrap method is a resampling method in which the bootstrap samples are obtained by resampling from the original sample. RESULTS: The described confidence interval calculation using bootstrap method does not require the sampling distribution antidotal potency ratio. This can serve as a substantial help for toxicologists, who are directed to employ the Dixon up-and-down method with the application of lower number of animals to determine lethal dose 50 values for characterizing the investigated toxic molecules and eventually for characterizing the antidotal protections by the test antidotal systems. CONCLUSION: The described method can serve as a useful tool in various other applications. Simplicity of the method makes it easier to do the calculation using most of the programming software packages. PMID:25237618
Flickinger, Allison; Christensen, Eric D.
2017-01-01
The Little Blue River in Jackson County, Missouri, was listed as impaired in 2012 due to Escherichia coli (E. coli) from urban runoff and storm sewers. A study was initiated to characterize E. coli concentrations and loads to aid in the development of a total maximum daily load implementation plan. Longitudinal sampling along the stream revealed spatial and temporal variability in E. coli loads. Regression models were developed to better represent E. coli variability in the impaired reach using continuous hydrologic and water-quality parameters as predictive parameters. Daily loads calculated from main-stem samples were significantly higher downstream compared to upstream even though there was no significant difference between the upstream and downstream measured concentrations and no significant conclusions could be drawn from model-estimated loads due to model-associated uncertainty. Increasing sample frequency could decrease the bias and increase the accuracy of the modeled results.
2014-01-01
Background Pedigree reconstruction using genetic analysis provides a useful means to estimate fundamental population biology parameters relating to population demography, trait heritability and individual fitness when combined with other sources of data. However, there remain limitations to pedigree reconstruction in wild populations, particularly in systems where parent-offspring relationships cannot be directly observed, there is incomplete sampling of individuals, or molecular parentage inference relies on low quality DNA from archived material. While much can still be inferred from incomplete or sparse pedigrees, it is crucial to evaluate the quality and power of available genetic information a priori to testing specific biological hypotheses. Here, we used microsatellite markers to reconstruct a multi-generation pedigree of wild Atlantic salmon (Salmo salar L.) using archived scale samples collected with a total trapping system within a river over a 10 year period. Using a simulation-based approach, we determined the optimal microsatellite marker number for accurate parentage assignment, and evaluated the power of the resulting partial pedigree to investigate important evolutionary and quantitative genetic characteristics of salmon in the system. Results We show that at least 20 microsatellites (ave. 12 alleles/locus) are required to maximise parentage assignment and to improve the power to estimate reproductive success and heritability in this study system. We also show that 1.5 fold differences can be detected between groups simulated to have differing reproductive success, and that it is possible to detect moderate heritability values for continuous traits (h2 ~ 0.40) with more than 80% power when using 28 moderately to highly polymorphic markers. Conclusion The methodologies and work flow described provide a robust approach for evaluating archived samples for pedigree-based research, even where only a proportion of the total population is sampled. The results demonstrate the feasibility of pedigree-based studies to address challenging ecological and evolutionary questions in free-living populations, where genealogies can be traced only using molecular tools, and that significant increases in pedigree assignment power can be achieved by using higher numbers of markers. PMID:24684698
Ding, Huanjun; Ducote, Justin L.; Molloi, Sabee
2012-01-01
Purpose: To investigate the feasibility of breast tissue composition in terms of water, lipid, and protein with a cadmium-zinc-telluride (CZT) based computed tomography (CT) system to help better characterize suspicious lesions. Methods: Simulations and experimental studies were performed using a spectral CT system equipped with a CZT-based photon-counting detector with energy resolution. Simulations of the figure-of-merit (FOM), the signal-to-noise ratio (SNR) of the dual energy image with respect to the square root of mean glandular dose (MGD), were performed to find the optimal configuration of the experimental acquisition parameters. A calibration phantom 3.175 cm in diameter was constructed from polyoxymethylene plastic with cylindrical holes that were filled with water and oil. Similarly, sized samples of pure adipose and pure lean bovine tissues were used for the three-material decomposition. Tissue composition results computed from the images were compared to the chemical analysis data of the tissue samples. Results: The beam energy was selected to be 100 kVp with a splitting energy of 40 keV. The tissue samples were successfully decomposed into water, lipid, and protein contents. The RMS error of the volumetric percentage for the three-material decomposition, as compared to data from the chemical analysis, was estimated to be approximately 5.7%. Conclusions: The results of this study suggest that the CZT-based photon-counting detector may be employed in the CT system to quantify the water, lipid, and protein mass densities in tissue with a relatively good agreement. PMID:22380361
NASA Astrophysics Data System (ADS)
Stock, Karl; Diebolder, Rolf; Hausladen, Florian; Hibst, Raimund
2014-03-01
It is well known that flashlamp pumped Er:YAG lasers allow efficient bone ablation due to strong absorption at 3μm by water. Preliminary experiments revealed also a newly developed diode pumped Er:YAG laser system (Pantec Engineering AG) to be an efficient tool for use for bone surgery. The aim of the present in vitro study is the investigation of a new power increased version of the laser system with higher pulse energy and optimization of the treatment set-up to get high cutting quality, efficiency, and ablation depth. Optical simulations were performed to achieve various focus diameters and homogeneous beam profile. An appropriate experimental set-up with two different focusing units, a computer controlled linear stage with sample holder, and a shutter unit was realized. By this we are able to move the sample (slices of pig bone) with a defined velocity during the irradiation. Cutting was performed under appropriate water spray by moving the sample back and forth. After each path the ablation depth was measured and the focal plane was tracked to the actual bottom of the groove. Finally, the cuts were analyzed by light microcopy regarding the ablation quality and geometry, and thermal effects. In summary, the results show that with carefully adapted irradiation parameters narrow and deep cuts (ablation depth > 6mm, aspect ratio approx. 20) are possible without carbonization. In conclusion, these in vitro investigations demonstrate that high efficient bone cutting is possible with the diode pumped Er:YAG laser system using appropriate treatment set-up and parameters.
An elastography method based on the scanning contact resonance of a piezoelectric cantilever
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fu, Ji; Li, Faxin, E-mail: lifaxin@pku.edu.cn
2013-12-15
Purpose: Most tissues may become significantly stiffer than their normal states when there are lesions inside. The tissue's modulus can then act as an identification parameter for clinic diagnosis of tumors or fibrosis, which leads to elastography. This study introduces a novel elastography method that can be used for modulus imaging of superficial organs. Methods: This method is based on the scanning contact-resonance of a unimorph piezoelectric cantilever. The cantilever vibrates in its bending mode with the tip pressed tightly on the sample. The contact resonance frequency of the cantilever-sample system is tracked at each scanning point, from which themore » sample's modulus can be derived based on a beam dynamic model and a contact mechanics model. Scanning is performed by a three-dimensional motorized stage and the whole system is controlled by a homemade software program based on LabVIEW. Results: Testing onin vitro beef tissues indicates that the fat and the muscle can be easily distinguished using this system, and the accuracy of the modulus measurement can be comparable with that of nanoindentation. Imaging on homemade gelatin phantoms shows that the depth information of the abnormalities can be qualitatively obtained by varying the pressing force. The detection limit of this elastography method is specially examined both experimentally and numerically. Results show that it can detect the typical lesions in superficial organs with the depth of several centimeters. The lateral resolution of this elastography method/system is better than 0.5 mm, and could be further enhanced by using more scanning points. Conclusions: The proposed elastography system can be regarded as a sensitive palpation robot, which may be very promising in early diagnosis of tumors in superficial organs such as breast and thyroid.« less
Montgomery, Eric; Gao, Chen; de Luca, Julie; Bower, Jessie; Attwood, Kristropher; Ylagan, Lourdes
2014-12-01
The Cellient(®) cell block system has become available as an alternative, partially automated method to create cell blocks in cytology. We sought to show a validation method for immunohistochemical (IHC) staining on the Cellient cell block system (CCB) in comparison with the formalin fixed paraffin embedded traditional cell block (TCB). Immunohistochemical staining was performed using 31 antibodies on 38 patient samples for a total of 326 slides. Split samples were processed using both methods by following the Cellient(®) manufacturer's recommendations for the Cellient cell block (CCB) and the Histogel method for preparing the traditional cell block (TCB). Interpretation was performed by three pathologists and two cytotechnologists. Immunohistochemical stains were scored as: 0/1+ (negative) and 2/3+ (positive). Inter-rater agreement for each antibody was evaluated for CCB and TCB, as well as the intra-rater agreement between TCB and CCB between observers. Interobserver staining concordance for the TCB was obtained with statistical significance (P < 0.05) in 24 of 31 antibodies. Interobserver staining concordance for the CCB was obtained with statistical significance in 27 of 31 antibodies. Intra-observer staining concordance between TCB and CCB was obtained with statistical significance in 24 of 31 antibodies tested. In conclusions, immunohistochemical stains on cytologic specimens processed by the Cellient system are reliable and concordant with stains performed on the same split samples processed via a formalin fixed-paraffin embedded (FFPE) block. The Cellient system is a welcome adjunct to cytology work-flow by producing cell block material of sufficient quality to allow the use of routine IHC. © 2014 Wiley Periodicals, Inc.
Nurses views on accepting the creation of a nurses’ health monitoring system
Rasoulzadeh, Nasrin; Abbaszadeh, Abbas; Zaefarian, Reza; Khounraz, Fariba
2017-01-01
Background Nurses’ health is often accompanied by various dangers due to the nature of their career. Therefore, it is required to monitor their health. Based on designing any system, users’ views should be investigated relative to the usefulness, necessity and acceptance of the system. Then, a designing and implementing process is conducted. Objective To investigate nurses’ views on accepting the creation of a Nurses’ Health Monitoring System. Methods This cross-sectional study was conducted in 2015. Sample size was 586 nurses of Shahid Beheshti University of Medical Sciences. Sampling was conducted using multi-stage random sampling method. Research tool was a two-section researcher-made questionnaire. In the first section, demographic data were studied and in the second section, a twelve-item questionnaire was presented based on technology acceptance model. Five-item questions were regulated on perceived usefulness (PU) and perceived ease of use (PEU) and views towards creating this system. Validity of the questionnaire was approved by content validity and content validity index and its reliability was approved by Cronbach’s alpha. Data were analyzed using SPSS16 and descriptive statistics (frequency distribution, percentage, mean). Results The majority of participants (75.3%) were females between 25–35 years of age (44.4%) and (58.2%) were married. Mean work experience was 11.5±8.19. Mean perceived usefulness (PU) (17.36±2.66) and perceived ease of use (PEU) (16.75±2.65) and views towards using a Nurses’ Health Monitoring System was (16.220±3.05). Conclusion Over two-thirds of nurses demonstrated perceived usefulness and perceived ease of use as well as positive views towards creating a nurses’ health monitoring system. It is recommended to design and implement a nurses’ health monitoring system based on local culture of Iranian nurses using IT in the health sector. PMID:28713521
Developmental validation of the PowerPlex(®) 21 System.
Ensenberger, Martin G; Hill, Carolyn R; McLaren, Robert S; Sprecher, Cynthia J; Storts, Douglas R
2014-03-01
The PowerPlex(®) 21 System is a STR multiplex that has been optimized for casework samples while still being capable of database workflows including direct amplification. The loci included in the multiplex offer increasing overlap with core loci used in different countries and regions throughout the world. The PowerPlex(®) 21 System contains D1S1656, D2S1338, D3S1358, D5S818, D6S1043, D7S820, D8S1179, D12S391, D13S317, D16S539, D18S51, D19S433, D21S11, Amelogenin, CSF1PO, FGA, Penta D, Penta E, TH01, TPOX, and vWA. These loci represent all 13 core CODIS loci in addition to loci commonly used in Asia and Europe. A developmental validation study was completed to document performance capabilities and limitations of the PowerPlex(®) 21 System. Data from this validation work served as the basis for the following conclusions: genotyping of single-source samples was reliable across a range of template DNA concentrations with >95% alleles called at 50 pg. Direct amplification of samples from FTA(®) storage cards was successfully performed using the reagents provided with the system and modified cycling protocols provided in the technical manual. Mixture analysis showed that over 95% of minor alleles were detected at 1:9 ratios. Reaction conditions including volume and annealing temperature as well as the concentrations of primers, DNA polymerase, magnesium, and Master Mix were shown to be optimal and able to withstand moderate variations without affecting system performance. Reproducible results were generated by different users at different sites. Finally, concordance studies showed consistent results when comparing the PowerPlex(®) 21 System with other commercially available STR-genotyping systems. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Mansion, Guilhem; Parolly, Gerald; Crowl, Andrew A.; Mavrodiev, Evgeny; Cellinese, Nico; Oganesian, Marine; Fraunhofer, Katharina; Kamari, Georgia; Phitos, Dimitrios; Haberle, Rosemarie; Akaydin, Galip; Ikinci, Nursel; Raus, Thomas; Borsch, Thomas
2012-01-01
Background Speciose clades usually harbor species with a broad spectrum of adaptive strategies and complex distribution patterns, and thus constitute ideal systems to disentangle biotic and abiotic causes underlying species diversification. The delimitation of such study systems to test evolutionary hypotheses is difficult because they often rely on artificial genus concepts as starting points. One of the most prominent examples is the bellflower genus Campanula with some 420 species, but up to 600 species when including all lineages to which Campanula is paraphyletic. We generated a large alignment of petD group II intron sequences to include more than 70% of described species as a reference. By comparison with partial data sets we could then assess the impact of selective taxon sampling strategies on phylogenetic reconstruction and subsequent evolutionary conclusions. Methodology/Principal Findings Phylogenetic analyses based on maximum parsimony (PAUP, PRAP), Bayesian inference (MrBayes), and maximum likelihood (RAxML) were first carried out on the large reference data set (D680). Parameters including tree topology, branch support, and age estimates, were then compared to those obtained from smaller data sets resulting from “classification-guided” (D088) and “phylogeny-guided sampling” (D101). Analyses of D088 failed to fully recover the phylogenetic diversity in Campanula, whereas D101 inferred significantly different branch support and age estimates. Conclusions/Significance A short genomic region with high phylogenetic utility allowed us to easily generate a comprehensive phylogenetic framework for the speciose Campanula clade. Our approach recovered 17 well-supported and circumscribed sub-lineages. Knowing these will be instrumental for developing more specific evolutionary hypotheses and guide future research, we highlight the predictive value of a mass taxon-sampling strategy as a first essential step towards illuminating the detailed evolutionary history of diverse clades. PMID:23209646
Noorani, Ayesha; Lynch, Andy G.; Achilleos, Achilleas; Eldridge, Matthew; Bower, Lawrence; Weaver, Jamie M.J.; Crawte, Jason; Ong, Chin-Ann; Shannon, Nicholas; MacRae, Shona; Grehan, Nicola; Nutzinger, Barbara; O'Donovan, Maria; Hardwick, Richard; Tavaré, Simon; Fitzgerald, Rebecca C.
2017-01-01
The scientific community has avoided using tissue samples from patients that have been exposed to systemic chemotherapy to infer the genomic landscape of a given cancer. Esophageal adenocarcinoma is a heterogeneous, chemoresistant tumor for which the availability and size of pretreatment endoscopic samples are limiting. This study compares whole-genome sequencing data obtained from chemo-naive and chemo-treated samples. The quality of whole-genomic sequencing data is comparable across all samples regardless of chemotherapy status. Inclusion of samples collected post-chemotherapy increased the proportion of late-stage tumors. When comparing matched pre- and post-chemotherapy samples from 10 cases, the mutational signatures, copy number, and SNV mutational profiles reflect the expected heterogeneity in this disease. Analysis of SNVs in relation to allele-specific copy-number changes pinpoints the common ancestor to a point prior to chemotherapy. For cases in which pre- and post-chemotherapy samples do show substantial differences, the timing of the divergence is near-synchronous with endoreduplication. Comparison across a large prospective cohort (62 treatment-naive, 58 chemotherapy-treated samples) reveals no significant differences in the overall mutation rate, mutation signatures, specific recurrent point mutations, or copy-number events in respect to chemotherapy status. In conclusion, whole-genome sequencing of samples obtained following neoadjuvant chemotherapy is representative of the genomic landscape of esophageal adenocarcinoma. Excluding these samples reduces the material available for cataloging and introduces a bias toward the earlier stages of cancer. PMID:28465312
Bouffard, Jeff; Bry, Jeff; Smith, Shamayne; Bry, Rhonda
2008-12-01
Much of the criminological literature testing rational choice theory has utilized hypothetical scenarios presented to university students. Although this research generally supports rational choice theory, a common criticism is that conclusions from these studies may not generalize to samples of actual offenders. This study proceeds to examine this issue in two steps. First, a traditional sample of university students is examined to determine how various costs and benefits relate to their hypothetical likelihood of offending. Then the same data collection procedures are employed with a somewhat different sample of younger, adjudicated, and institutionalized offenders to determine whether the conclusions drawn from the student sample generalize to this offender sample. Results generally suggest that the content and process of hypothetical criminal decision making differ in the sample of known offenders relative to the university students. Limitations of the current study, as well as suggestions for future research, are discussed.
A VLT/NACO survey for triple and quadruple systems among visual pre-main sequence binaries
NASA Astrophysics Data System (ADS)
Correia, S.; Zinnecker, H.; Ratzka, Th.; Sterzik, M. F.
2006-12-01
Aims.This paper describes a systematic search for high-order multiplicity among wide visual Pre-Main Sequence (PMS) binaries. Methods: .We conducted an Adaptive Optics survey of a sample of 58 PMS wide binaries from various star-forming regions, which include 52 T Tauri systems with mostly K- and M-type primaries, with the NIR instrument NACO at the VLT. Results: .Of these 52 systems, 7 are found to be triple (2 new) and 7 quadruple (1 new). The new close companions are most likely physically bound based on their probability of chance projection and, for some of them, on their position on a color-color diagram. The corresponding degree of multiplicity among wide binaries (number of triples and quadruples divided by the number of systems) is 26.9 ± 7.2% in the projected separation range ~0.07 arcsec -12'', with the largest contribution from the Taurus-Auriga cloud. We also found that this degree of multiplicity is twice in Taurus compared to Ophiuchus and Chamaeleon for which the same number of sources are present in our sample. Considering a restricted sample composed of systems at distance 140-190 pc, the degree of multiplicity is 26.8 ± 8.1%, in the separation range 10/14 AU-1700/2300 AU (30 binaries, 5 triples, 6 quadruples). The observed frequency agrees with results from previous multiplicity surveys within the uncertainties, although a significant overabundance of quadruple systems compared to triple systems is apparent. Tentatively including the spectroscopic pairs in our restricted sample and comparing the multiplicity fractions to those measured for solar-type main-sequence stars in the solar neighborhood leads to the conclusion that both the ratio of triples to binaries and the ratio of quadruples to triples seems to be in excess among young stars. Most of the current numerical simulations of multiple star formation, and especially smoothed particles hydrodynamics simulations, over-predict the fraction of high-order multiplicity when compared to our results. The circumstellar properties around the individual components of our high-order multiple systems tend to favor mixed systems (i.e. systems including components of wTTS and cTTS type), which is in general agreement with previous studies of disks in binaries, with the exception of Taurus, where we find a preponderance of similar type of components among the multiples studied.
Jones, Abigail; Legido-Quigley, Helena
2015-01-01
Objective To explore the feasibility of health systems strengthening from the perspective of international healthcare implementers and donors in South Sudan. Design A qualitative interview study, with thematic analysis using the WHO health system building blocks framework. Setting South Sudan. Participants 17 health system practitioners, working for international agencies in South Sudan, were purposively sampled for their knowledge and experiences of health systems strengthening, services delivery, health policy and politics in South Sudan. Results Participants universally reported the health workforce as insufficient and of low capacity and service delivery as poor, while access to medicines was restricted by governmental lack of commitment in undertaking procurement and supply. However, progress was clear in improved county health department governance, health management information system functionality, increased health worker salary harmonisation and strengthened financial management. Conclusions Resurgent conflict and political tensions have negatively impacted all health system components and maintaining or continuing health system strengthening has become extremely challenging. A coordinated approach to balancing humanitarian need particularly in conflict-affected areas, with longer term development is required so as not to lose improvements gained. PMID:26700280
Bull, Tyler Preston; Malvey, Donna M; Szalma, James Leo
2016-01-01
Background While much is known about factors that facilitate telehealth adoption, less is known about why adoption does or does not occur in specific populations, such as students. Objective This study aims to examine the perceptions of telehealth systems within a large student sample. Methods Undergraduate students (N=315) participated in a survey of the perceived advantages and disadvantages of telehealth technologies. The responses to the survey were analyzed using thematic analysis. Results We found that students were likely to adopt telehealth systems for the following reasons: (1) the system worked efficiently, (2) the convenience of telehealth, and (3) to gain access to health services. Students also perceived several disadvantages to telehealth systems, such as issues of trust (ie, security, privacy), the impersonal nature of telehealth systems, and they were concerned about the potential for major system errors. Conclusion By understanding the current barriers to telehealth adoption in a cohort of students, we can not only better anticipate the future needs of this group, but also incorporate such needs into the design of future telehealth systems. PMID:27731865
The Incident Command System: a literature review.
Jensen, Jessica; Thompson, Steven
2016-01-01
Given the foundational and the fundamental role that the Incident Command System (ICS) is intended to play in on-scene response efforts across the United States, it is important to determine what is known about the system and how this is known. Accordingly, this study addresses the following research question: 'How has research explored the ICS?'. To probe this question, a methodological review of the scant, but widening, pool of research literature directly related to the ICS was conducted. This paper reports on the findings of the analysis related to the focus, theoretical frameworks, population and sampling, methods, results, and conclusions of the existing research literature. While undertaken using different methodological approaches, the ICS research suggests that the system may be limited in its usefulness. In addition, the paper discusses the implications of the research for the state of knowledge of the system and for the direction of future research. © 2016 The Author(s). Disasters © Overseas Development Institute, 2016.
NASA Astrophysics Data System (ADS)
Rohleder, N.; Wirth, D.; Fraßl, W.; Kowoll, R.; Schlemmer, M.; Vogler, S.; Kirsch, K. A.; Kirschbaum, C.; Gunga, H.-C.
2005-08-01
Limited data are available on the response of stress systems to microgravity. Increased activity of stress systems is reported during space flight, but unchanged or decreased activity during simulated microgravity. We here investigated the impact of head-out water immersion on the activity of the hypothalamus-pituitary-adrenal (HPA) axis and the sympathetic-adrenal-medullary (SAM) system.Eight healthy young men were exposed to a six-hour water immersion in a thermo neutral bath and a control condition. Saliva samples were taken before, during, and after interventions to assess cortisol as an index for HPA axis activity, and salivary α-amylase as an index for SAM system activity.Cortisol levels uniformly decreased during both conditions. Amylase levels increased during both conditions, but were significantly lower during the first half of water immersion compared to the control condition.In conclusion, the HPA axis is not influenced by simulated microgravity, while SAM system activity shows initial decreases during water immersion.
Validation of a multiplex electrochemiluminescent immunoassay platform in human and mouse samples
Bastarache, J.A.; Koyama, T.; Wickersham, N.E; Ware, L.B.
2014-01-01
Despite the widespread use of multiplex immunoassays, there are very few scientific reports that test the accuracy and reliability of a platform prior to publication of experimental data. Our laboratory has previously demonstrated the need for new assay platform validation prior to use of biologic samples from large studies in order to optimize sample handling and assay performance. In this study, our goal was to test the accuracy and reproducibility of an electrochemiluminescent multiplex immunoassay platform (Meso Scale Discovery, MSD®) and compare this platform to validated, singleplex immunoassays (R&D Systems®) using actual study subject (human plasma and mouse bronchoalveolar lavage fluid (BALF) and plasma) samples. We found that the MSD platform performed well on intra- and inter-assay comparisons, spike and recovery and cross-platform comparisons. The mean intra-assay CV% and range for MSD was 3.49 (0.0-10.4) for IL-6 and 2.04 (0.1-7.9) for IL-8. The correlation between values for identical samples measured on both MSD and R&D was R=0.97 for both analytes. The mouse MSD assay had a broader range of CV% with means ranging from 9.5-28.5 depending on the analyte. The range of mean CV% was similar for single plex ELISAs at 4.3-23.7 depending on the analyte. Regardless of species or sample type, CV% was more variable at lower protein concentrations. In conclusion, we validated a multiplex electrochemiluminscent assay system and found that it has superior test characteristics in human plasma compared to mouse BALF and plasma. Both human and MSD assays compared favorably to well-validated singleplex ELISA's PMID:24768796
2017-01-01
Objective To determine whether less invasive endometrial (EM) aspiration biopsy is adequately accurate for evaluating treatment outcomes compared to the dilatation and curettage (D&C) biopsy in early-stage endometrial cancer (EC) patients treated with high dose oral progestin and levonorgestrel intrauterine system (LNG-IUS). Methods We conducted a prospective observational study with patients younger than 40 years who were diagnosed with clinical stage IA, The International Federation of Gynecology and Obstetrics grade 1 or 2 endometrioid adenocarcinoma and sought to maintain their fertility. The patients were treated with medroxyprogesterone acetate 500 mg/day and LNG-IUS. Treatment responses were evaluated every 3 months. EM aspiration biopsy was conducted after LNG-IUS removal followed D&C. The tissue samples were histologically compared. The diagnostic concordance rate of the two tests was examined with κ statistics. Results Twenty-eight pairs of EM samples were obtained from five patients. The diagnostic concordance rate of D&C and EM aspiration biopsy was 39.3% (κ value=0.26). Of the seven samples diagnosed as normal with D&C, three (42.8%) were diagnosed as normal by using EM aspiration biopsy. Of the eight samples diagnosed with endometrioid adenocarcinoma by using D&C, three (37.5%) were diagnosed with endometrioid adenocarcinoma by using EM aspiration biopsy. Of the 13 complex EM hyperplasia samples diagnosed with the D&C, five (38.5%) were diagnosed with EM hyperplasia by using EM aspiration biopsy. Of the samples obtained through EM aspiration, 46.4% were insufficient for histological evaluation. Conclusion To evaluate the treatment responses of patients with early-stage EC treated with high dose oral progestin and LNG-IUS, D&C should be conducted after LNG-IUS removal. PMID:27670255
Coutsoudis, Anna; Israel-Ballard, Kiersten; Chaudhri, Rohit; Perin, Noah; Mlisana, Koleka
2015-01-01
Abstract Human milk provides crucial nutrition and immunologic protection for infants. When a mother's own milk is unavailable, donated human milk, pasteurized to destroy bacteria and viruses, is a lifesaving replacement. Flash-heat pasteurization is a simple, low-cost, and commonly used method to make milk safe, but currently there is no system to monitor milk temperature, which challenges quality control. FoneAstra, a smartphone-based mobile pasteurization monitor, removes this barrier by guiding users through pasteurization and documenting consistent and safe practice. This study evaluated FoneAstra's efficacy as a quality control system, particularly in resource-limited settings, by comparing bacterial growth in donor milk flash-heated with and without the device at a neonatal intensive care unit in Durban, South Africa. Materials and Methods: For 100 samples of donor milk, one aliquot each of prepasteurized milk, milk flash-heated without FoneAstra, and milk pasteurized with FoneAstra was cultured on routine agar for bacterial growth. Isolated bacteria were identified and enumerated. Results: In total, 300 samples (three from each donor sample) were analyzed. Bacterial growth was found in 86 of the 100 samples before any pasteurization and one of the 100 postpasteurized samples without FoneAstra. None of the samples pasteurized using FoneAstra showed bacterial growth. Conclusions: Both pasteurization methods were safe and effective. FoneAstra, however, provides the additional benefits of user-guided temperature monitoring and data tracking. By improving quality assurance and standardizing the pasteurization process, FoneAstra can support wide-scale implementation of human milk banks in resource-limited settings, increasing access and saving lives. PMID:25668396
NASA Astrophysics Data System (ADS)
Hu, Yecui; Du, Zhangliu; Wang, Qibing; Li, Guichun
2016-07-01
The conversion of natural vegetation to human-managed ecosystems, especially the agricultural systems, may decrease soil organic carbon (SOC) and total nitrogen (TN) stocks. The objective of present study was to assess SOC and TN stocks losses by combining deep sampling with mass-based calculations upon land-use changes in a typical karst area of southwestern China. We quantified the changes from native forest to grassland, secondary shrub, eucalyptus plantation, sugarcane and corn fields (both defined as croplands), on the SOC and TN stocks down to 100 cm depth using fixed-depth (FD) and equivalent soil mass (ESM) approaches. The results showed that converting forest to cropland and other types significantly led to SOC and TN losses, but the extent depended on both sampling depths and calculation methods selected (i.e., FD or ESM). On average, the shifting from native forest to cropland led to SOC losses by 19.1, 25.1, 30.6, 36.8 and 37.9 % for the soil depths of 0-10, 0-20, 0-40, 0-60 and 0-100 cm, respectively, which highlighted that shallow sampling underestimated SOC losses. Moreover, the FD method underestimated SOC and TN losses for the upper 40 cm layer, but overestimated the losses in the deeper layers. We suggest that the ESM together with deep sampling should be encouraged to detect the differences in SOC stocks. In conclusion, the conversion of forest to managed systems, in particular croplands significantly decreased in SOC and TN stocks, although the effect magnitude to some extent depended on sampling depth and calculation approach selected.
In situ hybridisation of EBV DNA-DNA hybrids using wet heat in polypropylene containers.
Labrecque, L G
1992-01-01
AIMS: To explore procedures designed to optimise DNA-DNA in situ hybridisation, using cells infected with Epstein-Barr virus (EBV) and tissues and subfragments of the EBV DNA as probes. METHODS: The denaturation step occurred in a polypropylene container, using wet heat generated by a hot water container, the pressure cooker, or the microwave oven, without coverslips, reaching a temperature of 121 degrees C or more in these two last systems. Two different visualisation systems were used. RESULTS: Fixed cells and tumours harbouring a high and medium to low copy number (a few hundreds to 33 copies per cell), were clearly labelled, using a simple reiterated subfragment (BamW) of the EBV DNA, and fresh frozen cells, harbouring a very low copy number (one to two on average) labelled using BamW as well as BamH (single non-reiterated 6 kilobase subfragment). CONCLUSION: This is a valuable alternative technique for DNA-DNA ISH that can be used in fresh frozen samples as well as fixed samples. Images PMID:1336018
Galmozzi, E; Facchetti, F; Degasperi, E; Aghemo, A; Lampertico, P
2013-02-01
Recently, genome-wide association studies (GWAS) in patients with chronic hepatitis C virus (HCV) infection have identified two functional single nucleotide polymorphisms (SNPs) in the inosine triphosphatase (ITPA) gene, that are associated strongly and independently with hemolytic anemia in patients exposed to pegylated-interferon (Peg-IFN) plus ribavirin (RBV) combined therapy. Here has been developed a simplified allele discrimination polymerase chain reaction (PCR) assay named allelic inhibition of displacement activity (AIDA) for evaluation of ITPA polymorphisms. AIDA system relies on three unlabeled primers only, two outer common primers and one inner primer with allele-specific 3' terminus mismatch. DNA samples from 192 patients with chronic HCV infection were used to validate the AIDA system and results were compared with the gold standard TaqMan(®) SNP genotyping assay. Concordant data were obtained for all samples, granting for high specificity of the method. In conclusion, AIDA is a practical one-tube method to reproducibly and to assess accurately rs7270101 and rs1127354 ITPA SNPs. Copyright © 2012 Elsevier B.V. All rights reserved.
Hirdes, John P; Poss, Jeff W; Curtin-Telegdi, Nancy
2008-01-01
Background Home care plays a vital role in many health care systems, but there is evidence that appropriate targeting strategies must be used to allocate limited home care resources effectively. The aim of the present study was to develop and validate a methodology for prioritizing access to community and facility-based services for home care clients. Methods Canadian and international data based on the Resident Assessment Instrument – Home Care (RAI-HC) were analyzed to identify predictors for nursing home placement, caregiver distress and for being rated as requiring alternative placement to improve outlook. Results The Method for Assigning Priority Levels (MAPLe) algorithm was a strong predictor of all three outcomes in the derivation sample. The algorithm was validated with additional data from five other countries, three other provinces, and an Ontario sample obtained after the use of the RAI-HC was mandated. Conclusion The MAPLe algorithm provides a psychometrically sound decision-support tool that may be used to inform choices related to allocation of home care resources and prioritization of clients needing community or facility-based services. PMID:18366782
The mass spectrum of the white dwarfs in cataclysmic binaries - Supplementary computations
NASA Astrophysics Data System (ADS)
Ritter, H.; Ozkan, M. T.
1986-10-01
Numerical computations supplementing those of Ritter and Burkert (1986) for the study of observational selection in favor of massive white dwarfs among cataclysmic binaries (CBs) are presented. In particular the contribution of CBs beyond the period minimum and the influence of the inclination and of limb-darkening of the accretion disk are investigated. It is found that: (1) the main conclusions of Ritter and Burkert remain unchanged; (2) neither the inclusion of CBs containing a black-dwarf secondary nor the variation of the inclination or limb-darkening change the selection significantly; (3) in a magnitude-limited sample, about 22 percent of the ultra-short-period CBs contain a degenerate secondary; (4) the mean inclination of the accretion disk in a magnitude-limited sample is always close to 60 deg; (5) the fraction of eclipsing systems is of order 10-15 percent at m(v) = 10.0; (6) the mean inclination and the fraction of eclipsing systems increases with the limiting magnitude; and (7) the intrinsic space density of CBs is n(CB) approximately .0001-.0002/cu pc.
Characterizing 3D sensors using the 3D modulation transfer function
NASA Astrophysics Data System (ADS)
Kellner, Timo; Breitbarth, Andreas; Zhang, Chen; Notni, Gunther
2018-03-01
The fields of optical 3D measurement system applications are continuously expanding and becoming more and more diverse. To evaluate appropriate systems for various measurement tasks, comparable parameters are necessary, whereas the 3D modulation transfer function (3D-MTF) has been established as a further criterion. Its aim is the determination of the system response between the measurement of a straight, sharp-edged cube and its opposite ideal calculated one. Within the scope of this work simulations and practical investigations regarding the 3D-MTF’s influences and its main issues are specifically investigated. Therefore, different determined edge radii representing the high-frequency spectra lead to various decreasing 3D-MTF characteristics. Furthermore, rising sampling frequencies improve its maximum transfer value to a saturation point in dependence of the radius. To approve these results of previous simulations, three fringe projection scanners were selected to determine the diversity. As the best 3D-MTF characteristic, a saturated transfer value of H_3D( f_N, 3D) = 0.79 has been identified at a sufficient sampling frequency, which is reached at four times the Nyquist limit. This high 3D resolution can mainly be achieved due to an improved camera projector interaction. Additionally, too small sampling ratios lead to uncertainties in the edge function determination, while higher ratios do not show major improvements. In conclusion, the 3D-MTF algorithm has thus been practically verified and its repeatability as well as its robustness have been confirmed.
Investigations on the potential of a low power diode pumped Er:YAG laser system for oral surgery
NASA Astrophysics Data System (ADS)
Stock, Karl; Wurm, Holger; Hausladen, Florian; Wagner, Sophia; Hibst, Raimund
2015-02-01
Flash lamp pumped Er:YAG-lasers are used in clinical practice for dental applications successfully. As an alternative, several diode pumped Er:YAG laser systems (Pantec Engineering AG) become available, with mean laser power of 2W, 15W, and 30W. The aim of the presented study is to investigate the potential of the 2W Er:YAG laser system for oral surgery. At first an appropriate experimental set-up was realized with a beam delivery and both, a focusing unit for non-contact tissue cutting and a fiber tip for tissue cutting in contact mode. In order to produce reproducible cuts, the samples (porcine gingiva) were moved by a computer controlled translation stage. On the fresh samples cutting depth and quality were determined by light microscopy. Afterwards histological sections were prepared and microscopically analyzed regarding cutting depth and thermal damage zone. The experiments show that low laser power ≤ 2W is sufficient to perform efficient oral soft tissue cutting with cut depth up to 2mm (sample movement 2mm/s). The width of the thermal damage zone can be controlled by the irradiation parameters within a range of about 50μm to 110μm. In general, thermal injury is more pronounced using fiber tips in contact mode compared to the focused laser beam. In conclusion the results reveal that even the low power diode pumped Er:YAG laser is an appropriate tool for oral surgery.
Sampling properties of directed networks
NASA Astrophysics Data System (ADS)
Son, S.-W.; Christensen, C.; Bizhani, G.; Foster, D. V.; Grassberger, P.; Paczuski, M.
2012-10-01
For many real-world networks only a small “sampled” version of the original network may be investigated; those results are then used to draw conclusions about the actual system. Variants of breadth-first search (BFS) sampling, which are based on epidemic processes, are widely used. Although it is well established that BFS sampling fails, in most cases, to capture the IN component(s) of directed networks, a description of the effects of BFS sampling on other topological properties is all but absent from the literature. To systematically study the effects of sampling biases on directed networks, we compare BFS sampling to random sampling on complete large-scale directed networks. We present new results and a thorough analysis of the topological properties of seven complete directed networks (prior to sampling), including three versions of Wikipedia, three different sources of sampled World Wide Web data, and an Internet-based social network. We detail the differences that sampling method and coverage can make to the structural properties of sampled versions of these seven networks. Most notably, we find that sampling method and coverage affect both the bow-tie structure and the number and structure of strongly connected components in sampled networks. In addition, at a low sampling coverage (i.e., less than 40%), the values of average degree, variance of out-degree, degree autocorrelation, and link reciprocity are overestimated by 30% or more in BFS-sampled networks and only attain values within 10% of the corresponding values in the complete networks when sampling coverage is in excess of 65%. These results may cause us to rethink what we know about the structure, function, and evolution of real-world directed networks.
Biostatistics Series Module 5: Determining Sample Size
Hazra, Avijit; Gogtay, Nithya
2016-01-01
Determining the appropriate sample size for a study, whatever be its type, is a fundamental aspect of biomedical research. An adequate sample ensures that the study will yield reliable information, regardless of whether the data ultimately suggests a clinically important difference between the interventions or elements being studied. The probability of Type 1 and Type 2 errors, the expected variance in the sample and the effect size are the essential determinants of sample size in interventional studies. Any method for deriving a conclusion from experimental data carries with it some risk of drawing a false conclusion. Two types of false conclusion may occur, called Type 1 and Type 2 errors, whose probabilities are denoted by the symbols σ and β. A Type 1 error occurs when one concludes that a difference exists between the groups being compared when, in reality, it does not. This is akin to a false positive result. A Type 2 error occurs when one concludes that difference does not exist when, in reality, a difference does exist, and it is equal to or larger than the effect size defined by the alternative to the null hypothesis. This may be viewed as a false negative result. When considering the risk of Type 2 error, it is more intuitive to think in terms of power of the study or (1 − β). Power denotes the probability of detecting a difference when a difference does exist between the groups being compared. Smaller α or larger power will increase sample size. Conventional acceptable values for power and α are 80% or above and 5% or below, respectively, when calculating sample size. Increasing variance in the sample tends to increase the sample size required to achieve a given power level. The effect size is the smallest clinically important difference that is sought to be detected and, rather than statistical convention, is a matter of past experience and clinical judgment. Larger samples are required if smaller differences are to be detected. Although the principles are long known, historically, sample size determination has been difficult, because of relatively complex mathematical considerations and numerous different formulas. However, of late, there has been remarkable improvement in the availability, capability, and user-friendliness of power and sample size determination software. Many can execute routines for determination of sample size and power for a wide variety of research designs and statistical tests. With the drudgery of mathematical calculation gone, researchers must now concentrate on determining appropriate sample size and achieving these targets, so that study conclusions can be accepted as meaningful. PMID:27688437
Zonta, Marco Antonio; Velame, Fernanda; Gema, Samara; Filassi, Jose Roberto; Longatto-Filho, Adhemar
2014-01-01
Background Breast cancer is the second cause of death in women worldwide. The spontaneous breast nipple discharge may contain cells that can be analyzed for malignancy. Halo® Mamo Cyto Test (HMCT) was recently developed as an automated system indicated to aspirate cells from the breast ducts. The objective of this study was to standardize the methodology of sampling and sample preparation of nipple discharge obtained by the automated method Halo breast test and perform cytological evaluation in samples preserved in liquid medium (SurePath™). Methods We analyzed 564 nipple fluid samples, from women between 20 and 85 years old, without history of breast disease and neoplasia, no pregnancy, and without gynecologic medical history, collected by HMCT method and preserved in two different vials with solutions for transport. Results From 306 nipple fluid samples from method 1, 199 (65%) were classified as unsatisfactory (class 0), 104 (34%) samples were classified as benign findings (class II), and three (1%) were classified as undetermined to neoplastic cells (class III). From 258 samples analyzed in method 2, 127 (49%) were classified as class 0, 124 (48%) were classified as class II, and seven (2%) were classified as class III. Conclusion Our study suggests an improvement in the quality and quantity of cellular samples when the association of the two methodologies is performed, Halo breast test and the method in liquid medium. PMID:29147397
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoegg, Edward D.; Marcus, R. Kenneth; Hager, George J.
RATIONALE: The field of highly accurate and precise isotope ratio (IR) analysis has been dominated by inductively coupled plasma and thermal ionization mass spectrometers. While these instruments are considered the gold standard for IR analysis, the International Atomic Energy Agency desires a field deployable instrument capable of accurately and precisely measuring U isotope ratios. METHODS: The proposed system interfaces the liquid sampling – atmospheric pressure glow discharge (LS-APGD) ion source with a high resolution Exactive Orbitrap mass spectrometer. With this experimental setup certified U isotope standards and unknown samples were analyzed. The accuracy and precision of the system were thenmore » determined. RESULTS: The LS-APGD /Exactive instrument measures a certified reference material of natural U (235U/238U = 0.007258) as 0.007041 with a relative standard deviation of 0.158% meeting the International Target Values for Uncertainty for the destructive analysis of U. Additionally, when three unknowns measured and compared to the results from an ICP multi collector instrument, there is no statistical difference between the two instruments.CONCLUSIONS: The LS-APGD / Orbitrap system, while still in the preliminary stages of development, offers highly accurate and precise IR analysis that suggest a paradigm shift in the world of IR analysis. Furthermore, the portability of the LS-APGD as an elemental ion source combined with the low overhead and small size of the Orbitrap suggest that the instrumentation is capable of being field deployable.With liquid sampling glow discharge-Orbitrap MS, isotope ratio and precision performance improves with rejection of concomitant ion species.« less
Long-term detection of methyltestosterone (ab-) use by a yeast transactivation system.
Wolf, Sylvi; Diel, Patrick; Parr, Maria Kristina; Rataj, Felicitas; Schänzer, Willhelm; Vollmer, Günter; Zierau, Oliver
2011-04-01
The routinely used analytical method for detecting the abuse of anabolic steroids only allows the detection of molecules with known analytical properties. In our supplementary approach to structure-independent detection, substances are identified by their biological activity. In the present study, urines excreted after oral methyltestosterone (MT) administration were analyzed by a yeast androgen screen (YAS). The aim was to trace the excretion of MT or its metabolites in human urine samples and to compare the results with those from the established analytical method. MT and its two major metabolites were tested as pure compounds in the YAS. In a second step, the ability of the YAS to detect MT and its metabolites in urine samples was analyzed. For this purpose, a human volunteer ingested of a single dose of 5 mg methyltestosterone. Urine samples were collected after different time intervals (0-307 h) and were analyzed in the YAS and in parallel by GC/MS. Whereas the YAS was able to trace MT in urine samples at least for 14 days, the detection limits of the GC/MS method allowed follow-up until day six. In conclusion, our results demonstrate that the yeast reporter gene system could detect the activity of anabolic steroids like methyltestosterone with high sensitivity even in urine. Furthermore, the YAS was able to detect MT abuse for a longer period of time than classical GC/MS. Obviously, the system responds to long-lasting metabolites yet unidentified. Therefore, the YAS can be a powerful (pre-) screening tool with the potential that to be used to identify persistent or late screening metabolites of anabolic steroids, which could be used for an enhancement of the sensitivity of GC/MS detection techniques.
2013-01-01
Background Nontuberculous mycobacteria (NTM) are environmental opportunistic pathogens found in natural and human-engineered waters, including drinking water distribution systems and household plumbing. This pilot study examined the frequency of occurrence of NTM in household potable water samples in Mexico City. Potable water samples were collected from the “main house faucet” and kitchen faucet. The presence of aerobic-mesophilic bacteria (AMB), total coliforms (TC), fecal coliforms (FC) and NTM species were determined. Mycobacteria species were identified by PCR restriction enzyme pattern analysis (PRA) of the 65-kDa heat shock protein gene (hsp65) and sequencing of the hypervariable region 2 (V2) of the 16S rRNA gene and of the rpoB gene. Results AMB (<100 CFU/ml) were present in 118 out of 120 samples; only two samples were outside guidelines ranges (>100 CFU/ml). TC and FC were detected in four and one samples, respectively. NTM species were recovered from 16% samples (19/120) and included M. mucogenicum (nine), M. porcinum (three), M. avium (three), M. gordonae (one), M. cosmeticum (one), M. fortuitum (one), and Mycobacterium sp (one). All household water samples that contained NTM complied with the standards required to grade the water as “good quality” potable water. Conclusion Household potable water may be a potential source of NTM infection in Mexico City. PMID:24330835
Genovese, C.; Facciolà, A.; Palamara, M.A.R.; Squeri, R.
2017-01-01
Summary Introduction. Nosocomial infections are one of the greatest problems in public health. Several studies have highlighted the role played by the hospital environment as a possible source of transmission of nosocomial pathogens. Methods. A five-year monitoring of bacterial contamination on healthcare workers hands, surfaces most closely in contact with inpatient wards, operating theatres and "at rest" and "in use" operating theatre air samples. For the samples, we used sterile swabs, contact slides, manual API, and automated VITEK systems for identification. Results. In the five-year period, a total of 9396 samples were collected and analysed. In ward patients, 4398 samplings were carried out with 4.7%, 9.4%, 7%, 10.8% and 7.9% positive results respectively from 2010 to 2014. For hands, 648 samplings were carried out, with a positivity of 40.74%. In operating theatres, 4188 samples were taken, with a positivity of 11.9%. Regarding air in empty and full theatres, 1962 samplings were carried out with a positivity rate equal to 31.9%. The monitoring showed a low rate of contamination with a progressive decrease in the fiveyear period on operating theatres surfaces and hands, while there was an increase in the surgical site wards and in the air of operating rooms. Conclusions. Our investigation has revealed the presence of pathogens on the assessed surfaces and the need for environmental monitoring, which can be a valuable tool for reducing contamination. PMID:28900357
Characterization of double oxide system Cu-Cr-O supported on γ-Al2O3
NASA Astrophysics Data System (ADS)
Cherkezova-Zheleva, Z.; Kolev, H.; Krstić, J.; Dimitrov, D.; Ivanov, K.; Loncarević, D.; Jovanović, D.; Mitov, I.
2009-09-01
Series of alumina supported chromium-copper catalysts were prepared by co-impregnation method. The samples were characterized by X-ray diffraction, X-ray photoelectron spectroscopy and UV-visible diffuse reflectance spectroscopy. Dispersion and porosity was also obtained. The experimental and catalytic test results have drawn a conclusion that an interaction between copper and chromium ions takes place. This interaction is responsible for the enhanced catalytic activity of studied catalysts in reaction of total oxidation of industrial formaldehyde production exhaust gas, which contains CO, dimethyl ether and methanol as main components.
Enhanced sampling simulation analysis of the structure of lignin in the THF–water miscibility gap
Smith, Micholas Dean; Petridis, Loukas; Cheng, Xiaolin; ...
2016-01-26
Using temperature replica-exchange molecular dynamics, we characterize a globule-to-coil transition for a softwood-like lignin biopolymer in a tetrahydrofuran (THF)-water cosolvent system at temperatures at which the cosolvent undergoes a de-mixing transition. The lignin is found to be in a coil state, similar to that in the high-temperature miscible region. Analysis of the transition kinetics indicates that THF acts in a surfactant-like fashion. In conclusion, the present study thus suggests that THF-water based pretreatments may efficiently remove lignin from biomass even at relatively low (non-water boiling) temperatures.
Low cycle fatigue properties of MAR-M-246 Hf in hydrogen. [a cast nickel-base alloy
NASA Technical Reports Server (NTRS)
Warren, J. R.
1979-01-01
The transverse, low cycle fatigue properties were determined for directionally solidified and single crystal samples of a cast nickel-base alloy proposed for use in space propulsion systems in pure or partial high pressure hydrogen environments at elevated temperatures. The test temperature was 760 C (1400F) and the pressure of the gaseous hydrogen was 34.5 MPa (5000 psig). Low cycle fatique life was established by strain controlled testing using smooth specimens and a servohydraulic closed-loop test machine modified with a high pressure environmental chamber. Results and conclusions are discussed.
In-Situ Propellant Production on Mars: A Sabatier/Electrolysis Demonstration Plant
NASA Astrophysics Data System (ADS)
Clark, David L.
1997-01-01
An efficient, reliable propellant production plant has been developed for use on Mars. Using a Sabatier reactor in conjunction with a water electrolysis system, a complete demonstration plant has produced methane and liquid oxygen from simulated Martian atmosphere. The production plant has demonstrated high efficiency, extended duration production and autonomous operations. This paper presents the results and conclusions relating to eventual use in a Mars sample return mission. This work was funded by the Jet Propulsion Laboratory (JPL). The production plant was built and tested at the Propulsion Center of Lockheed Martin at the Denver Colorado facility.
The Vocational Interests of a Sample of Optometry Students.
ERIC Educational Resources Information Center
Emling, Robert C.; And Others
1981-01-01
The Strong-Campbell Interest Inventory, with a vocational title called Optometry, was used to profile a sample of second-year optometry students and to compare them with samples of practicing optometrists. One conclusion questions these students' compatibility with older practitioners. (MLW)
A Simple Method to Quantitate IP-10 in Dried Blood and Plasma Spots
Aabye, Martine G.; Eugen-Olsen, Jesper; Werlinrud, Anne Marie; Holm, Line Lindebo; Tuuminen, Tamara; Ravn, Pernille; Ruhwald, Morten
2012-01-01
Background Antigen specific release of IP-10 is an established marker for infection with M.tuberculosis. Compared to IFN-γ, IP-10 is released in 100-fold higher concentrations enabling the development of novel assays for detection. Dried blood spots are a convenient sample for high throughput newborn screening. Aim To develop a robust and sensitive ELISA-based assay for IP-10 detection in plasma, dried blood spots (DBS) and dried plasma spots (DPS); to validate the ELISA in clinically relevant samples; and to assess the performance of the assay for detection of Cytomegalovirus (CMV) and M.tuberculosis specific immune responses. Method We raised mice and rat monoclonal antibodies against human IP-10 and developed an ELISA. The assay was validated and applied to the detection of CMV and M.tuberculosis specific responses in 18 patients with immune reactivity towards M.tuberculosis and 32 healthy controls of which 22 had immune reactivity towards CMV and none towards M.tuberculosis. We compared the performance of this new assay to IFN-γ. Results The ELISA was reliable for IP-10 detection in both plasma and filter paper samples. The linear range of the ELISA was 2.5–600 pg/ml. IFN-γ was not readily detectable in DPS samples. IP-10 was stabile in filter paper samples for at least 4 weeks at 37°C. The correlation between IP-10 detected in plasma, DPS and DBS samples was excellent (r2>0.97). Conclusions This newly developed assay is reliable for IP-10 quantification in plasma, DBS and DPS samples from antigen stimulated and non-stimulated whole blood. The filter paper assays enable easy sample acquisition and transport at ambient temperature e.g. via the postal system. The system can potentially simplify diagnostic assays for M.tuberculosis and CMV infection. PMID:22761744
CRN5EXP: Expert system for statistical quality control
NASA Technical Reports Server (NTRS)
Hentea, Mariana
1991-01-01
The purpose of the Expert System CRN5EXP is to assist in checking the quality of the coils at two very important mills: Hot Rolling and Cold Rolling in a steel plant. The system interprets the statistical quality control charts, diagnoses and predicts the quality of the steel. Measurements of process control variables are recorded in a database and sample statistics such as the mean and the range are computed and plotted on a control chart. The chart is analyzed through patterns using the C Language Integrated Production System (CLIPS) and a forward chaining technique to reach a conclusion about the causes of defects and to take management measures for the improvement of the quality control techniques. The Expert System combines the certainty factors associated with the process control variables to predict the quality of the steel. The paper presents the approach to extract data from the database, the reason to combine certainty factors, the architecture and the use of the Expert System. However, the interpretation of control charts patterns requires the human expert's knowledge and lends to Expert Systems rules.
Broderick, Joan E.; Schneider, Stefan; Junghaenel, Doerte U.; Schwartz, Joseph E.; Stone, Arthur A.
2013-01-01
Objective Evaluation of known group validity, ecological validity, and test-retest reliability of four domain instruments from the Patient Reported Outcomes Measurement System (PROMIS) in osteoarthritis (OA) patients. Methods Recruitment of an osteoarthritis sample and a comparison general population (GP) through an Internet survey panel. Pain intensity, pain interference, physical functioning, and fatigue were assessed for 4 consecutive weeks with PROMIS short forms on a daily basis and compared with same-domain Computer Adaptive Test (CAT) instruments that use a 7-day recall. Known group validity (comparison of OA and GP), ecological validity (comparison of aggregated daily measures with CATs), and test-retest reliability were evaluated. Results The recruited samples matched (age, sex, race, ethnicity) the demographic characteristics of the U.S. sample for arthritis and the 2009 Census for the GP. Compliance with repeated measurements was excellent: > 95%. Known group validity for CATs was demonstrated with large effect sizes (pain intensity: 1.42, pain interference: 1.25, and fatigue: .85). Ecological validity was also established through high correlations between aggregated daily measures and weekly CATs (≥ .86). Test-retest validity (7-day) was very good (≥ .80). Conclusion PROMIS CAT instruments demonstrated known group and ecological validity in a comparison of osteoarthritis patients with a general population sample. Adequate test-retest reliability was also observed. These data provide encouraging initial data on the utility of these PROMIS instruments for clinical and research outcomes in osteoarthritis patients. PMID:23592494
Effect of turbidity on chlorination efficiency and bacterial persistence in drinking water.
LeChevallier, M W; Evans, T M; Seidler, R J
1981-01-01
To define interrelationships between elevated turbidities and the efficiency of chlorination in drinking water, experiments were performed to measure bacterial survival, chlorine demand, and interference with microbiological determinations. Experiments were conducted on the surface water supplies for communities which practice chlorination as the only treatment. Therefore, the conclusions of this study apply only to such systems. Results indicated that disinfection efficiency (log10 of the decrease in coliform numbers) was negatively correlated with turbidity and was influenced by season, chlorine demand of the samples, and the initial coliform level. Total organic carbon was found to be associated with turbidity and was shown to interfere with maintenance of a free chlorine residual by creating a chlorine demand. Interference with coliform detection in turbid waters could be demonstrated by the recovery of typical coliforms from apparently negative filters. The incidence of coliform masking in the membrane filter technique was found to increase as the turbidity of the chlorinated samples increased. the magnitude of coliform masking in the membrane filter technique increased from less than 1 coliform per 100 ml in water samples of less than 5 nephelometric turbidity units to greater than 1 coliform per 100 ml in water samples of greater than 5 nephelometric turbidity units. Statistical models were developed to predict the impact of turbidity on drinking water quality. The results justify maximum contaminant levels for turbidity in water entering a distribution system as stated in the National Primary Drinking Water Regulations of the Safe Drinking Water Act. Images PMID:7259162
Chronic Fatigue Syndrome versus Systemic Exertion Intolerance Disease
Jason, Leonard A.; Sunnquist, Madison; Brown, Abigail; Newton, Julia L.; Strand, Elin Bolle; Vernon, Suzanne D.
2015-01-01
Background The Institute of Medicine has recommended a change in the name and criteria for Chronic Fatigue Syndrome (CFS), renaming the illness Systemic Exertion Intolerance Disease (SEID). The new SEID case definition requires substantial reductions or impairments in the ability to engage in pre-illness activities, unrefreshing sleep, post-exertional malaise, and either cognitive impairment or orthostatic intolerance. Purpose In the current study, samples were generated through several different methods and were used to compare this new case definition to previous case definitions for CFS, Myalgic Encephalomyelitis (ME-ICC), Myalgic Encephalomyelitis/Chronic Fatigue Syndrome (ME/CFS), as well as a case definition developed through empirical methods. Methods We used a cross-sectional design with samples from tertiary care settings, a biobank sample, and other forums. 796 patients from the US, Great Britain, and Norway completed the DePaul Symptom Questionnaire. Results Findings indicated that the SEID criteria identified 88% of participants in the samples analyzed, which is comparable to the 92% that met the Fukuda criteria. The SEID case definition was compared to a four item empiric criteria, and findings indicated that the four item empiric criteria identified a smaller, more functionally limited and symptomatic group of patients. Conclusion The recently developed SEID criteria appears to identify a group comparable in size to the Fukuda et al. criteria, but a larger group of patients than the Canadian ME/CFS and ME criteria, and selects more patients who have less impairment and fewer symptoms than a four item empiric criteria. PMID:26345409
Aligning the Measurement of Microbial Diversity with Macroecological Theory
Stegen, James C.; Hurlbert, Allen H.; Bond-Lamberty, Ben; ...
2016-09-23
The number of microbial operational taxonomic units (OTUs) within a community is akin to species richness within plant/animal (‘macrobial’) systems. A large literature documents OTU richness patterns, drawing comparisons to macrobial theory. There is, however, an unrecognized fundamental disconnect between OTU richness and macrobial theory: OTU richness is commonly estimated on a per-individual basis, while macrobial richness is estimated per-area. Furthermore, the range or extent of sampled environmental conditions can strongly influence a study’s outcomes and conclusions, but this is not commonly addressed when studying OTU richness. Here we (i) propose a new sampling approach that estimates OTU richness per-massmore » of soil, which results in strong support for species energy theory, (ii) use data reduction to show how support for niche conservatism emerges when sampling across a restricted range of environmental conditions, and (iii) show how additional insights into drivers of OTU richness can be generated by combining different sampling methods while simultaneously considering patterns that emerge by restricting the range of environmental conditions. We propose that a more rigorous connection between microbial ecology and macrobial theory can be facilitated by exploring how changes in OTU richness units and environmental extent influence outcomes of data analysis. While fundamental differences between microbial and macrobial systems persist (e.g., species concepts), we suggest that closer attention to units and scale provide tangible and immediate improvements to our understanding of the processes governing OTU richness and how those processes relate to drivers of macrobial species richness.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stegen, James C.; Hurlbert, Allen H.; Bond-Lamberty, Ben
The number of microbial operational taxonomic units (OTUs) within a community is akin to species richness within plant/animal (‘macrobial’) systems. A large literature documents OTU richness patterns, drawing comparisons to macrobial theory. There is, however, an unrecognized fundamental disconnect between OTU richness and macrobial theory: OTU richness is commonly estimated on a per-individual basis, while macrobial richness is estimated per-area. Furthermore, the range or extent of sampled environmental conditions can strongly influence a study’s outcomes and conclusions, but this is not commonly addressed when studying OTU richness. Here we (i) propose a new sampling approach that estimates OTU richness per-massmore » of soil, which results in strong support for species energy theory, (ii) use data reduction to show how support for niche conservatism emerges when sampling across a restricted range of environmental conditions, and (iii) show how additional insights into drivers of OTU richness can be generated by combining different sampling methods while simultaneously considering patterns that emerge by restricting the range of environmental conditions. We propose that a more rigorous connection between microbial ecology and macrobial theory can be facilitated by exploring how changes in OTU richness units and environmental extent influence outcomes of data analysis. While fundamental differences between microbial and macrobial systems persist (e.g., species concepts), we suggest that closer attention to units and scale provide tangible and immediate improvements to our understanding of the processes governing OTU richness and how those processes relate to drivers of macrobial species richness.« less
Zhang, Dapeng; Bi, Peng; Lv, Fan; Zhang, Jie; Hiller, Janet E
2008-10-01
This study compared the difference between two samples of men who have sex with men (MSM) in Harbin, China, using cross-sectional data that were collected via the Internet and through conventional venue-based outreach. All participants in both samples lived in or nearby Harbin in northeast China. Results showed that the Internet sample was significantly younger, more educated and more likely to be students and to self-identify as homosexual than the community sample. After controlling for demographic characteristics, the community sample was more likely to have had sex with females (OR 2.01, CI 1.22-3.30, p=0.006) and to have had > or =6 male partners in the previous six months than the Internet sample (OR 4.88, CI 3.51-6.80, p<0.001). No significant difference was observed in the prevalence of unprotected anal intercourse, exchanging sex for money, exchanging money for sex or illicit drug use between the two samples. For those seeking sex both on the Internet and in traditional gay venues, participants in the community sample were nearly three times more likely to have had > or =6 male partners during the previous six months than those in the Internet sample (p=0.001). In conclusion, the online and offline samples of MSM are significantly different and carry different levels of risk for HIV transmission. Using the Internet as a data collection method may serve as an additional mechanism for the existing gay venue-based behavioral surveillance system in China.
High throughput MLVA-16 typing for Brucella based on the microfluidics technology
2011-01-01
Background Brucellosis, a zoonosis caused by the genus Brucella, has been eradicated in Northern Europe, Australia, the USA and Canada, but remains endemic in most areas of the world. The strain and biovar typing of Brucella field samples isolated in outbreaks is useful for tracing back source of infection and may be crucial for discriminating naturally occurring outbreaks versus bioterrorist events, being Brucella a potential biological warfare agent. In the last years MLVA-16 has been described for Brucella spp. genotyping. The MLVA band profiles may be resolved by different techniques i.e. the manual agarose gels, the capillary electrophoresis sequencing systems or the microfluidic Lab-on-Chip electrophoresis. In this paper we described a high throughput system of MLVA-16 typing for Brucella spp. by using of the microfluidics technology. Results The Caliper LabChip 90 equipment was evaluated for MLVA-16 typing of sixty-three Brucella samples. Furthermore, in order to validate the system, DNA samples previously resolved by sequencing system and Agilent technology, were de novo genotyped. The comparison of the MLVA typing data obtained by the Caliper equipment and those previously obtained by the other analysis methods showed a good correlation. However the outputs were not accurate as the Caliper DNA fragment sizes showed discrepancies compared with real data and a conversion table from observed to expected data was created. Conclusion In this paper we described the MLVA-16 using a rapid, sophisticated microfluidics technology for detection of amplification product sizes. The comparison of the MLVA typing data produced by Caliper LabChip 90 system with the data obtained by different techniques showed a general concordance of the results. Furthermore this platform represents a significant improvement in terms of handling, data acquiring, computational efficiency and rapidity, allowing to perform the strain genotyping in a time equal to one sixth respect to other microfluidics systems as e.g. the Agilent 2100 bioanalyzer. Finally, this platform can be considered a valid alternative to standard genotyping techniques, particularly useful dealing with a large number of samples in short time. These data confirmed that this technology represents a significative advancement in high-throughput accurate Brucella genotyping. PMID:21435217
Fattebert, Jean-Luc; Lau, Edmond Y.; Bennion, Brian J.; ...
2015-10-22
Enzymes are complicated solvated systems that typically require many atoms to simulate their function with any degree of accuracy. We have recently developed numerical techniques for large scale First-Principles molecular dynamics simulations and applied them to study the enzymatic reaction catalyzed by acetylcholinesterase. We carried out Density functional theory calculations for a quantum mechanical (QM) sub- system consisting of 612 atoms with an O(N) complexity finite-difference approach. The QM sub-system is embedded inside an external potential field representing the electrostatic effect due to the environment. We obtained finite temperature sampling by First-Principles molecular dynamics for the acylation reaction of acetylcholinemore » catalyzed by acetylcholinesterase. Our calculations shows two energies barriers along the reaction coordinate for the enzyme catalyzed acylation of acetylcholine. In conclusion, the second barrier (8.5 kcal/mole) is rate-limiting for the acylation reaction and in good agreement with experiment.« less
Inter-laboratory comparison of the in vivo comet assay including three image analysis systems.
Plappert-Helbig, Ulla; Guérard, Melanie
2015-12-01
To compare the extent of potential inter-laboratory variability and the influence of different comet image analysis systems, in vivo comet experiments were conducted using the genotoxicants ethyl methanesulfonate and methyl methanesulfonate. Tissue samples from the same animals were processed and analyzed-including independent slide evaluation by image analysis-in two laboratories with extensive experience in performing the comet assay. The analysis revealed low inter-laboratory experimental variability. Neither the use of different image analysis systems, nor the staining procedure of DNA (propidium iodide vs. SYBR® Gold), considerably impacted the results or sensitivity of the assay. In addition, relatively high stability of the staining intensity of propidium iodide-stained slides was found in slides that were refrigerated for over 3 months. In conclusion, following a thoroughly defined protocol and standardized routine procedures ensures that the comet assay is robust and generates comparable results between different laboratories. © 2015 Wiley Periodicals, Inc.
Monnier, Stéphanie; Cox, David G; Albion, Tim; Canzian, Federico
2005-01-01
Background Single Nucleotide Polymorphism (SNP) genotyping is a major activity in biomedical research. The Taqman technology is one of the most commonly used approaches. It produces large amounts of data that are difficult to process by hand. Laboratories not equipped with a Laboratory Information Management System (LIMS) need tools to organize the data flow. Results We propose a package of Visual Basic programs focused on sample management and on the parsing of input and output TaqMan files. The code is written in Visual Basic, embedded in the Microsoft Office package, and it allows anyone to have access to those tools, without any programming skills and with basic computer requirements. Conclusion We have created useful tools focused on management of TaqMan genotyping data, a critical issue in genotyping laboratories whithout a more sophisticated and expensive system, such as a LIMS. PMID:16221298
Internet-based profiler system as integrative framework to support translational research
Kim, Robert; Demichelis, Francesca; Tang, Jeffery; Riva, Alberto; Shen, Ronglai; Gibbs, Doug F; Mahavishno, Vasudeva; Chinnaiyan, Arul M; Rubin, Mark A
2005-01-01
Background Translational research requires taking basic science observations and developing them into clinically useful tests and therapeutics. We have developed a process to develop molecular biomarkers for diagnosis and prognosis by integrating tissue microarray (TMA) technology and an internet-database tool, Profiler. TMA technology allows investigators to study hundreds of patient samples on a single glass slide resulting in the conservation of tissue and the reduction in inter-experimental variability. The Profiler system allows investigator to reliably track, store, and evaluate TMA experiments. Here within we describe the process that has evolved through an empirical basis over the past 5 years at two academic institutions. Results The generic design of this system makes it compatible with multiple organ system (e.g., prostate, breast, lung, renal, and hematopoietic system,). Studies and folders are restricted to authorized users as required. Over the past 5 years, investigators at 2 academic institutions have scanned 656 TMA experiments and collected 63,311 digital images of these tissue samples. 68 pathologists from 12 major user groups have accessed the system. Two groups directly link clinical data from over 500 patients for immediate access and the remaining groups choose to maintain clinical and pathology data on separate systems. Profiler currently has 170 K data points such as staining intensity, tumor grade, and nuclear size. Due to the relational database structure, analysis can be easily performed on single or multiple TMA experimental results. The TMA module of Profiler can maintain images acquired from multiple systems. Conclusion We have developed a robust process to develop molecular biomarkers using TMA technology and an internet-based database system to track all steps of this process. This system is extendable to other types of molecular data as separate modules and is freely available to academic institutions for licensing. PMID:16364175
An in-house assay for BK polyomavirus quantification using the Abbott m2000 RealTime system.
Muldrew, Kenneth L; Lovett, Jennie L
2013-11-01
BK polyomavirus (BKPyV) quantification is useful for monitoring renal transplant patient response to therapy. The Abbott m2000 RealTime System employed by some clinical laboratories to perform US Food and Drug Administration-approved assays can also be used to develop in-house assays such as the one presented here. This study aimed to validate an in-house quantitative real-time PCR assay targeting the BKPyV major capsid VP1 gene for assessment of viral load using the Abbott m2000 RealTime System. BKPyV load was measured in 95 urine and plasma samples previously tested for BKPyV by one of three laboratories (46 BKPyV-positive samples consisting of 35 plasma and 11 urine samples; 49 samples negative for BKPyV consisting of 47 plasma and two urine samples). Two additional plasma specimens from the College of American Pathologists proficiency testing survey were also analysed. Precision studies were performed by diluting a high-viral-titre patient sample into BKPyV-negative pooled plasma to create high-positive (6.16 log10 copies ml(-1)) and low-positive (3.16 log10 copies ml(-1)) samples. For precision studies of inter-assay variability, a high-positive (7.0 log10 copies ml(-1)) and a low-positive (3.0 log10 copies ml(-1)) sample were measured in 20 separate runs. The assay's limit of quantification and limit of detection were 2.70 and 2.25 log10 copies ml(-1), respectively. The assay was linear from 2.70 to 9.26 log10 copies ml(-1). Of the 48 known positives, 43 were detected as positive, with three reported by the reference laboratory as values lower than the limit of detection. Two known positives at 3.27 and 3.80 log10 copies ml(-1) tested negative by the m2000 BKPyV assay. Of the 49 known negative samples, 48 were negative by the m2000 BKPyV load assay, with one sample confirmed positive by a reference laboratory. Qualitative analysis prior to discrepancy testing demonstrated a sensitivity of 89.58 % and a specificity of 97.96 %. Precision studies demonstrated inter-assay coefficients of variation of 0.63 % (high positive) and 4.38 % (low positive). Genotyping was performed on 22 patient samples, of which 21 (95.45 %) were type I and one (4.55 %) was type II. In conclusion, the m2000 BKPyV viral load assay sensitivity, specificity, linear range, precision and cost effectiveness make it an attractive methodology for clinical laboratories using the Abbott m2000 RealTime System.
NASA Astrophysics Data System (ADS)
Bertolini, G.; Marques, J. C.; Hartley, A. J.; Scherer, C.; Macdonald, D.; Hole, M.; Stipp Basei, M. A. A. S.; Frantz, J. C.; Rosa, A. A. S.
2017-12-01
Large desert basins (>1.000.000 km²) are likely to contain sediment derived from different sources due to variations in factors such as wind direction, sand availability, and sediment influx. Provenance analysis is key to determining sediment sources and to constrain the nature of the sediment fill in desert basins. The Cretaceous Botucatu Desert dunefield extended across a large area of the interior of the SW Gondwana and was then buried by extensive lava flows that covered the active erg. The onset of volcanic activity triggered climatic and topographic variations that changed the depositional setting, however, the aeolian system remained active during this time period. Twenty samples were collected along the southern border of the basin (Brazil and Uruguay). Heavy mineral (HM) and petrographic analyses indicate very mature sediment, with a high ZTR index and quartz dominated sandstones. Despite the regularity of high ZTR index, garnet input occurs in eastern samples. Ten samples were selected for MC-LA-ICP-MS zircon dating with the aim of comparing pre- and syn-volcanic sandstones. More than 800 detrital zircons (DZ) were analyzed and the results allowed the identification of 5 relevant peaks interpreted as: 1) Choiyoi volcanism; 2) Famatian Cycle; 3) Brazilian Cycle (BC); 4) Grenvillian Cycle (GC); 5) Transamazonic Cycle. The DZ ages from the pre and syn-volcanic sandstones show no significant variation. However, when comparing the provenance between the eastern and western areas, samples from the eastern border show a major BC contribution (61%), while the western samples contain 40%. The GC contribution is more significant in the western part of the basin (>18%), contrasting with 6% in eastern samples. The main conclusions are: 1) the DZ record reveals a distinct signature for sedimentary sources; 2) climatic and topographic changes caused by the onset of volcanic activity had no impact on DZ populations; 3) heavy mineral types are very similar in all samples, but the local presence of garnet suggests a more restricted contribution in eastern samples; 4) eastern samples also show differences in the DZ population with a more significant BC contribution. HM and DZ results show that proximal sources can modify sediment input character and changing provenance signatures in desert aeolian systems.
NASA Astrophysics Data System (ADS)
Schulte, Wolfgang; Thiele, Hans; Hofmann, Peter; Baglioni, Pietro
The ExoMars program will search for past and present life on Mars. ExoMars will address important scientific goals and demonstrate key in-situ enabling technologies. Among such technologies are the acquisition, preparation, distribution and analysis of samples from Mars surface rocks and from the subsurface. The 2018 mission will land an ESA rover on Mars which carries a sample preparation and distribution system (SPDS) and a suite of analytical instruments, the Pasteur Payload with its Analytical Laboratory Drawer (ALD). Kayser-Threde GmbH (Germany) will be responsible for the SPDS as a subcontractor under the mission prime Thales Alenia Space. The SPDS comprises a number of complex mechanisms and mechanical devices designed to transport drill core samples within the rover analytical laboratory, to crush them to powder with a fine grain size, to portion discrete amounts of powdered sample material, to distribute and fill the material into sample containers and to prepare flat sample surfaces for scientific analysis. Breadboards of the crushing mechanism, the dosing mechanism and a distribution carousel with sample containers and a powder sample surface flattening mechanism were built and tested. Kayser-Threde, as a member of the Spanish led ExoMars Raman Instrument team, is also responsible for development of the Raman optical head, which will be mounted inside ALD and will inspect the crushed samples, when they are presented to the instrument by the distribution carousel. Within this activity, which is performed under contract with the Institute of Physical Chemistry of the University of Jena (Germany) and funded by the German DLR, Kayser-Threde can demonstrate Raman measurements with the optical head and a COTS laser and spectrometer and thus simulate the full Raman instrument optical path. An autofocus system with actuator and feedback optics is also part of this activity, which allows focusing the 50 m Raman spot on the surface of the powdered sample. Availability of both, the SPDS mechanisms and the Raman Spectrometer optical head at Kayser-Threde facilities allowed to demonstrate for the first time a sample preparation chain with a joint operation of the optical head. Mineral samples were crushed, dosed into sample containers on the carousel, flattened and then inspected by the Raman optical head. The samples were provided by the University of Jena, a member of the ExoMars Raman science team. This paper will give an overview of the breadboards developed so far for the ExoMars SPDS and the Raman optical head and illustrate the joint demonstration test setup of the SPDS with the instrument. The different behavior of different sample materials will be highlighted and first conclusions will be drawn on what could be learned from test setups combining the ExoMars SPDS and analytical instruments.
Tidd hot gas clean up program. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This Final Report on the Tidd Hot Gas Clean Up Program covers the period from initial Proof-of-Concept testing in August, 1990, through final equipment inspections in May, 1995. The Tidd Hot Gas Clean Up (HGCU) system was installed in the Tidd Pressurized Fluidized Bed Combustion (PFBC) Demonstration Plant, which is the first utility-scale PFBC plant in the United States. Detailed design work on the project began in July, 1990, and site construction began in December, 1991. Initial operation of the system occurred in May, 1992, and the hot gas filter was commissioned in October, 1992. The test program ended inmore » March, 1995, when the Tidd Plant was shut down following its four-year test program. Section 1.0 of this report is an executive summary of the project covering the project background, system description, test results and conclusions. Section 2.0 is an introduction covering the program objectives and schedule. Section 3.0 provides detailed descriptions of the system and its major components. Section 4.0 provides detailed results of all testing including observations and posttest inspection results. Sections 5.0 and 6.0 list the program conclusions and recommendations, respectively. Appendix I is a report prepared by Southern Research Institute on the properties of Tidd PFBC ash sampled during the test program. Appendix II is a report prepared by Westinghouse STC on the performance of candle filter fail-safe regenerator devices.« less
A straightforward method to compute average stochastic oscillations from data samples.
Júlvez, Jorge
2015-10-19
Many biological systems exhibit sustained stochastic oscillations in their steady state. Assessing these oscillations is usually a challenging task due to the potential variability of the amplitude and frequency of the oscillations over time. As a result of this variability, when several stochastic replications are averaged, the oscillations are flattened and can be overlooked. This can easily lead to the erroneous conclusion that the system reaches a constant steady state. This paper proposes a straightforward method to detect and asses stochastic oscillations. The basis of the method is in the use of polar coordinates for systems with two species, and cylindrical coordinates for systems with more than two species. By slightly modifying these coordinate systems, it is possible to compute the total angular distance run by the system and the average Euclidean distance to a reference point. This allows us to compute confidence intervals, both for the average angular speed and for the distance to a reference point, from a set of replications. The use of polar (or cylindrical) coordinates provides a new perspective of the system dynamics. The mean trajectory that can be obtained by averaging the usual cartesian coordinates of the samples informs about the trajectory of the center of mass of the replications. In contrast to such a mean cartesian trajectory, the mean polar trajectory can be used to compute the average circular motion of those replications, and therefore, can yield evidence about sustained steady state oscillations. Both, the coordinate transformation and the computation of confidence intervals, can be carried out efficiently. This results in an efficient method to evaluate stochastic oscillations.
Prevalence and association of welding related systemic and respiratory symptoms in welders
El-Zein, M; Malo, J; Infante-Rivard, C; Gautrin, D
2003-01-01
Background: The prevalence of welding related respiratory symptoms coexisting with welding related systemic symptoms in welders is unknown. Aims: To determine in a sample of welders the prevalence of coexisting welding related systemic symptoms indicative of metal fume fever (MFF) and welding related respiratory symptoms suggestive of occupational asthma (OA), and the strength and significance of any association between these two groups of symptoms. Methods: A respiratory symptoms questionnaire, a systemic symptoms questionnaire, and a questionnaire on occupational history were administered by telephone to 351 of a sample of 441 welders (79.6%) from two cities in Québec, Canada. Results: The co-occurrence of possible MFF (defined as having at least two symptoms of fever, feelings of flu, general malaise, chills, dry cough, metallic taste, and shortness of breath, occurring at the beginning of the working week, 3–10 hours after exposure to welding fumes) together with welding related respiratory symptoms suggestive of OA (defined as having at least two welding related symptoms of cough, wheezing, and chest tightness) was 5.8%. These two groups of symptoms were significantly associated (χ2 = 18.9, p < 0.001). Conclusion: There is a strong association between welding related MFF and welding related respiratory symptoms suggestive of OA. As such, MFF could be viewed as a pre-marker of welding related OA, a hypothesis that requires further investigation. PMID:12937186
Study of the Open Loop and Closed Loop Oscillator Techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Imel, George R.; Baker, Benjamin; Riley, Tony
This report presents the progress and completion of a five-year study undertaken at Idaho State University of the measurement of very small worth reactivity samples comparing open and closed loop oscillator techniques.The study conclusively demonstrated the equivalency of the two techniques with regard to uncertainties in reactivity values, i.e., limited by reactor noise. As those results are thoroughly documented in recent publications, in this report we will concentrate on the support work that was necessary. For example, we describe in some detail the construction and calibration of a pilot rod for the closed loop system. We discuss the campaign tomore » measure the required reactor parameters necessary for inverse-kinetics. Finally, we briefly discuss the transfer of the open loop technique to other reactor systems.« less
Study of the open loop and closed loop oscillator techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, Benjamin; Riley, Tony; Langbehn, Adam
This paper presents some aspects of a five year study undertaken at Idaho State University of the measurement of very small worth reactivity samples comparing open and closed loop oscillator techniques. The study conclusively demonstrated the equivalency of the two techniques with regard to uncertainties in reactivity values, i.e., limited by reactor noise. As those results are thoroughly documented in recent publications, in this paper we will concentrate on the support work that was necessary. For example, we describe in some detail the construction and calibration of a pilot rod for the closed loop system. We discuss the campaign tomore » measure the required reactor parameters necessary for inverse-kinetics. Finally, we briefly discuss the transfer of the open loop technique to other reactor systems. (authors)« less
Wu, Daxian; Tao, Shuhui; Liu, Shuiping; Zhou, Jiebin; Tan, Deming; Hou, Zhouhua
2017-07-28
To observe the sensitivity of transcription mediated amplification (TMA), and to compare its performance with real-time reverse transcription polymerase chain reaction (real-time RT-PCR) in detecting human immunodeficiency virus RNA (HIV RNA). Methods: TMA system was established with TaqMan probes, specific primers, moloney murine leukemia virus (MMLV) reverse transcriptase, T7 RNA polymerase, and reaction substrates. The sensitivity of TMA was evaluated by amplifying a group of 10-fold diluted HIV RNA standards which were transcribed in vitro. A total of 60 plasma of HIV infected patients were measured by TMA and Cobas Amplicor HIV-1 Monitor test to observe the positive rate. The correlation and concordance of the above two technologies were investigated by linear regression and Bland-Altman analysis. Results: TMA system was established successfully and HIV RNA transcribed standards at concentration of equal or more than 10 copies/mL could be detected by TMA technology. Among 60 samples of plasma from HIV infected patients, 46 were positively detected and 12 were negatively amplified by both TMA and Cobas reagents; 2 samples were positively tested by Cobas reagent but negatively tested by TMA system. The concordance rate of the two methods was 97.1% and the difference of positive detection rate between the two methods was not statistically significant (P>0.05). Linear regression was used for 46 samples which were positively detected by both TMA and Cobas reagents and showed an excellent correlation between the two reagents (r=0.997, P<0.001). Bland-Altma analysis revealed that the mean different value of HIV RNA levels for denary logarithm was 0.02. Forty-four samples were included in 95% of credibility interval of concordance. Conclusion: TMA system has the potential of high sensitivity. TMA and real-time RT-PCR keep an excellent correlation and consistency in detecting HIV RNA.
Caudron, Jean Michel; Schiavetti, Benedetta; Pouget, Corinne; Tsoumanis, Achilleas; Meessen, Bruno; Ravinetto, Raffaella
2018-01-01
Introduction The rapid globalisation of the pharmaceutical production and distribution has not been supported by harmonisation of regulatory systems worldwide. Thus, the supply systems in low-income and middle-income countries (LMICs) remain exposed to the risk of poor-quality medicines. To contribute to estimating this risk in the private sector in LMICs, we assessed the quality assurance system of a convenient sample of local private pharmaceutical distributors. Methods This descriptive study uses secondary data derived from the audits conducted by the QUAMED group at 60 local private pharmaceutical distributors in 13 LMICs. We assessed the distributors’ compliance with good distribution practices (GDP), general quality requirements (GQR) and cold chain management (CCM), based on an evaluation tool inspired by the WHO guidelines ’Model Quality Assurance System (MQAS) for procurement agencies'. Descriptive statistics describe the compliance for the whole sample, for distributors in sub-Saharan Africa (SSA) versus those in non-SSA, and for those in low-income countries (LICs) versus middle-income countries (MICs). Results Local private pharmaceutical distributors in our sample were non-compliant, very low-compliant or low-compliant for GQR (70%), GDP (60%) and CCM (41%). Only 7/60 showed good to full compliance for at least two criteria. Observed compliance varies by geographical region and by income group: maximum values are higher in non-SSA versus SSA and in MICs versus LICs, while minimum values are the same across different groups. Conclusion The poor compliance with WHO quality standards observed in our sample indicates a concrete risk that patients in LMICs are exposed to poor-quality or degraded medicines. Significant investments are needed to strengthen the regulatory supervision, including on private pharmaceutical distributors. An adapted standardised evaluation tool inspired by the WHO MQAS would be helpful for self-evaluation, audit and inspection purposes. PMID:29915671
High Prevalence of Anaplasma spp. in Small Ruminants in Morocco.
Ait Lbacha, H; Alali, S; Zouagui, Z; El Mamoun, L; Rhalem, A; Petit, E; Haddad, N; Gandoin, C; Boulouis, H-J; Maillard, R
2017-02-01
The prevalence of infection by Anaplasma spp. (including Anaplasma phagocytophilum) was determined using blood smear microscopy and PCR through screening of small ruminant blood samples collected from seven regions of Morocco. Co-infections of Anaplasma spp., Babesia spp, Theileria spp. and Mycoplasma spp. were investigated and risk factors for Anaplasma spp. infection assessed. A total of 422 small ruminant blood samples were randomly collected from 70 flocks. Individual animal (breed, age, tick burden and previous treatment) and flock data (GPS coordinate of farm, size of flock and livestock production system) were collected. Upon examination of blood smears, 375 blood samples (88.9%) were found to contain Anaplasma-like erythrocytic inclusion bodies. Upon screening with a large spectrum PCR targeting the Anaplasma 16S rRNA region, 303 (71%) samples were found to be positive. All 303 samples screened with the A. phagocytophilum-specific PCR, which targets the msp2 region, were found to be negative. Differences in prevalence were found to be statistically significant with regard to region, altitude, flock size, livestock production system, grazing system, presence of clinical cases and application of tick and tick-borne diseases prophylactic measures. Kappa analysis revealed a poor concordance between microscopy and PCR (k = 0.14). Agreement with PCR is improved by considering microscopy and packed cell volume (PCV) in parallel. The prevalence of double infections was found to be 1.7, 2.5 and 24% for Anaplasma-Babesia, Anaplasma-Mycoplasma and Anaplasma-Theileria, respectively. Co-infection with three or more haemoparasites was found in 1.6% of animals examined. In conclusion, we demonstrate the high burden of anaplasmosis in small ruminants in Morocco and the high prevalence of co-infections of tick-borne diseases. There is an urgent need to improve the control of this neglected group of diseases. © 2015 Blackwell Verlag GmbH.
Bonfiglio, Silvia; Vanni, Irene; Rossella, Valeria; Truini, Anna; Lazarevic, Dejan; Dal Bello, Maria Giovanna; Alama, Angela; Mora, Marco; Rijavec, Erika; Genova, Carlo; Cittaro, Davide; Grossi, Francesco; Coco, Simona
2016-08-30
Next Generation Sequencing (NGS) has become a valuable tool for molecular landscape characterization of cancer genomes, leading to a better understanding of tumor onset and progression, and opening new avenues in translational oncology. Formalin-fixed paraffin-embedded (FFPE) tissue is the method of choice for storage of clinical samples, however low quality of FFPE genomic DNA (gDNA) can limit its use for downstream applications. To investigate the FFPE specimen suitability for NGS analysis and to establish the performance of two solution-based exome capture technologies, we compared the whole-exome sequencing (WES) data of gDNA extracted from 5 fresh frozen (FF) and 5 matched FFPE lung adenocarcinoma tissues using: SeqCap EZ Human Exome v.3.0 (Roche NimbleGen) and SureSelect XT Human All Exon v.5 (Agilent Technologies). Sequencing metrics on Illumina HiSeq were optimal for both exome systems and comparable among FFPE and FF samples, with a slight increase of PCR duplicates in FFPE, mainly in Roche NimbleGen libraries. Comparison of single nucleotide variants (SNVs) between FFPE-FF pairs reached overlapping values >90 % in both systems. Both WES showed high concordance with target re-sequencing data by Ion PGM™ in 22 lung-cancer genes, regardless the source of samples. Exon coverage of 623 cancer-related genes revealed high coverage efficiency of both kits, proposing WES as a valid alternative to target re-sequencing. High-quality and reliable data can be successfully obtained from WES of FFPE samples starting from a relatively low amount of input gDNA, suggesting the inclusion of NGS-based tests into clinical contest. In conclusion, our analysis suggests that the WES approach could be extended to a translational research context as well as to the clinic (e.g. to study rare malignancies), where the simultaneous analysis of the whole coding region of the genome may help in the detection of cancer-linked variants.
Jin, Jong-Sik; Touyama, Mutsumi; Hisada, Takayoshi; Benno, Yoshimi
2012-11-01
Green tea is one of the most popular beverages in the world. Its beneficial health effects and components have been extensively reviewed. However, little is known about the influence of green tea consumption on the human intestinal microbiota (HIM), which plays a crucial role in human health. Ten volunteers who did not usually consume green tea, drank it for 10 days and then stopped drinking it for 7 days. Their fecal samples were collected at three time points: before beginning the 10-day green-tea regime, at the conclusion of that 10 days, and 7 days after stopping the regime. Their fecal samples were analyzed by terminal restriction fragment length polymorphism with specific primer-restriction enzyme systems for HIM and by using a real-time PCR method for the Bifidobacterium species. Although the HIM of each subject was relatively stable, the proportion of Bifidobacterium species played an important role in the classification of their fecal microbiota. Although there were inter-individual differences in the Bifidobacterium species, an overall tendency for the proportion of bifidobacteria to increase because of green tea consumption was noted. However, little change was observed in the composition of Bifidobacterium species in each sample. This suggests that the change in proportion was induced, not by an inter-species transition, but by an intra-species increase and/or decrease. In conclusion, green tea consumption might act as a prebiotic and improve the colon environment by increasing the proportion of the Bifidobacterium species. © 2012 The Societies and Wiley Publishing Asia Pty Ltd.
Fetal-Maternal Interactions in the Synepitheliochorial Placenta Using the eGFP Cloned Cattle Model
Mess, Andrea; Perecin, Felipe; Bressan, Fabiana Fernandes; Mesquita, Ligia Garcia; Miglino, Maria Angelica; Pimentel, José RodrigoValim; Neto, Paulo Fantinato; Meirelles, Flávio Vieira
2013-01-01
Background To investigate mechanisms of fetal-maternal cell interactions in the bovine placenta, we developed a model of transgenic enhanced Green Fluorescent Protein (t-eGFP) expressing bovine embryos produced by nuclear transfer (NT) to assess the distribution of fetal-derived products in the bovine placenta. In addition, we searched for male specific DNA in the blood of females carrying in vitro produced male embryos. Our hypothesis is that the bovine placenta is more permeable to fetal-derived products than described elsewhere. Methodology/Principal Findings Samples of placentomes, chorion, endometrium, maternal peripheral blood leukocytes and blood plasma were collected during early gestation and processed for nested-PCR for eGFP and testis-specific Y-encoded protein (TSPY), western blotting and immunohistochemistry for eGFP detection, as well as transmission electron microscopy to verify the level of interaction between maternal and fetal cells. TSPY and eGFP DNA were present in the blood of cows carrying male pregnancies at day 60 of pregnancy. Protein and mRNA of eGFP were observed in the trophoblast and uterine tissues. In the placentomes, the protein expression was weak in the syncytial regions, but intense in neighboring cells on both sides of the fetal-maternal interface. Ultrastructurally, our samples from t-eGFP expressing NT pregnancies showed to be normal, such as the presence of interdigitating structures between fetal and maternal cells. In addition, channels-like structures were present in the trophoblast cells. Conclusions/Significance Data suggested that there is a delivery of fetal contents to the maternal system on both systemic and local levels that involved nuclear acids and proteins. It not clear the mechanisms involved in the transfer of fetal-derived molecules to the maternal system. This delivery may occur through nonclassical protein secretion; throughout transtrophoblastic-like channels and/or by apoptotic processes previously described. In conclusion, the bovine synepitheliochorial placenta displays an intimate fetal-maternal interaction, similar to other placental types for instance human and mouse. PMID:23724045
[Peracetic acid: alternative to the sterilization of bronchofibroscopes].
Villate, J I; Barrón, J; Zalacaín, R; Urcelay, M I; Hernández, J M; Argumedo, M
1997-03-01
The Steris system for cold sterilization with peracetic acid was evaluated by effecting a series of contaminations of a fiberoptic bronchoscope (FB) with specimens of Pseudomonas aeruginosa, Acinetobacter baumanii and Mycobacterium kansasi. The FB was contaminated 24 times, 8 times by each microorganism, using specimens containing more than 10(8) cfu/ml. After fixing the secretions on the FB and washing it with enzyme soap, the BF was sterilized. Specimens were taken for culturing after contamination of the FB, after washing, immediately after sterilization and 1 hour after sterilization. No microorganism growth of any of the samples was detected either immediately after sterilization or one hour later. Microbiological data confirmed contamination of the FB after aspiration and fixation of the inoculate. Chemical and biological tests with B. stearothermophilus spores as specified by the manufacturer were correct in all cases: 24 contaminations and 52 processes of prior training. The efficacy of washing with enzyme soap before sterilization stands out. In 14 of the 24 samples, culture was negative after washing and in 7 the concentration of microorganisms was less than 500 cfu/ml, which confirms the need for appropriate washing before any disinfection or sterilization process is begun. In conclusion, the Steris system based on peracetic acid is an alternative to other systems for cold sterilization or high level disinfection.
Masking of endotoxin in surfactant samples: Effects on Limulus-based detection systems.
Reich, Johannes; Lang, Pierre; Grallert, Holger; Motschmann, Hubert
2016-09-01
Over the last few decades Limulus Amebocyte Lysate (LAL) has been the most sensitive method for the detection of endotoxins (Lipopolysaccharides) and is well accepted in a broad field of applications. Recently, Low Endotoxin Recovery (LER) in biopharmaceutical drug products has been noticed, whereby the detection of potential endotoxin contaminations is not ensured. Notably, most of these drug products contain surfactants, which can have crucial effects on the detectability of endotoxin. In order to analyze the driving forces of LER, endotoxin detection in samples containing nonionic surfactants in various buffer systems was investigated. The results show that the process of LER is kinetically controlled and temperature-dependent. Furthermore, only the simultaneous presence of nonionic surfactants and components capable of forming metal complexes resulted in LER. In addition, capacity experiments show that even hazardous amounts of endotoxin can remain undetectable within such formulation compositions. In conclusion, the LER phenomenon is caused by endotoxin masking and not by test interference. In this process, the supramolecular structure of endotoxin is altered and exhibits only a limited susceptibility in binding to the Factor C of Limulus-based detection systems. We propose a two-step mechanism of endotoxin masking by complex forming agents and nonionic surfactants. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.
2009-01-01
Background Bacteria used as indicators for pathogenic microorganisms in water are not considered adequate as enteric virus indicators. Surface water from a tropical high-altitude system located in Mexico City that receives rainwater, treated and non-treated wastewater used for irrigation, and groundwater used for drinking, was studied. Methods The presence of enterovirus, rotavirus, astrovirus, coliphage, coliform bacteria, and enterococci was determined during annual cycles in 2001 and 2002. Enteric viruses in concentrated water samples were detected by reverse transcriptase-polymerase chain reaction (RT-PCR). Coliphages were detected using the double agar layer method. Bacteria analyses of the water samples were carried out by membrane filtration. Results The presence of viruses and bacteria in the water used for irrigation showed no relationship between current bacterial indicator detection and viral presence. Coliphages showed strong association with indicator bacteria and enterovirus, but weak association with other enteric viruses. Enterovirus and rotavirus showed significant seasonal differences in water used for irrigation, although this was not clear for astrovirus. Conclusion Coliphages proved to be adequate faecal pollution indicators for the irrigation water studied. Viral presence in this tropical high-altitude system showed a similar trend to data previously reported for temperate zones. PMID:19860917
Zhu, Yanmei; Witt, Rachel E.; MacCallum, Julia K.; Jiang, Jack J.
2010-01-01
Objective In this study, a Voice over Internet Protocol (VoIP) communication based on G.729 protocol was simulated to determine the effects of this system on acoustic perturbation parameters of normal and pathological voice signals. Patients and Methods: Fifty recordings of normal voice and 48 recordings of pathological voice affected by laryngeal paralysis were transmitted through a VoIP communication system. The acoustic analysis programs of CSpeech and MDVP were used to determine the percent jitter and percent shimmer from the voice samples before and after VoIP transmission. The effects of three frequently used audio compression protocols (MP3, WMA, and FLAC) on the perturbation measures were also studied. Results It was found that VoIP transmission disrupts the waveform and increases the percent jitter and percent shimmer of voice samples. However, after VoIP transmission, significant discrimination between normal and pathological voices affected by laryngeal paralysis was still possible. It was found that the lossless compression method FLAC does not exert any influence on the perturbation measures. The lossy compression methods MP3 and WMA increase percent jitter and percent shimmer values. Conclusion This study validates the feasibility of these transmission and compression protocols in developing remote voice signal data collection and assessment systems. PMID:20588051
Are carnivores universally good sentinels of plague?
Brinkerhoff, R Jory; Collinge, Sharon K; Bai, Ying; Ray, Chris
2009-10-01
Sylvatic plague, caused by the bacterium Yersinia pestis, is a flea-borne disease that primarily affects rodents but has been detected in over 200 mammal species worldwide. Mammalian carnivores are routinely surveyed as sentinels of local plague activity, since they can present antibodies to Y. pestis infection but show few clinical signs. In Boulder County, Colorado, USA, plague epizootic events are episodic and occur in black-tailed prairie dogs. Enzootic hosts are unidentified as are plague foci. For three years, we systematically sampled carnivores in two distinct habitat types to determine whether carnivores may play a role in maintenance or transmission of Y. pestis and to identify habitats associated with increased plague prevalence. We sampled 83 individuals representing six carnivore species and found only two that had been exposed to Y. pestis. The low overall rate of plague exposure in carnivores suggests that plague may be ephemeral in this study system, and thus we cannot draw any conclusions regarding habitat-associated plague foci or temporal changes in plague activity. Plague epizootics involving prairie dogs were confirmed in this study system during two of the three years of this study, and we therefore suggest that the targeting carnivores to survey for plague may not be appropriate in all ecological systems.
[Anaerobic bacteria isolated from patients with suspected anaerobic infections].
Ercis, Serpil; Tunçkanat, Ferda; Hasçelik, Gülşen
2005-10-01
The study involved 394 clinical samples sent to the Clinical Microbiology Laboratory of Hacettepe University Adult Hospital between January 1997 and May 2004 for anaerobic cultivation. Since multiple cultures from the same clinical samples of the same patient were excluded, the study was carried on 367 samples. The anaerobic cultures were performed in anaerobic jar using AnaeroGen kits (Oxoid, Basingstoke, U.K.) or GENbox (bioMérieux, Lyon, France). The isolates were identified by both classical methods and "BBL Crystal System" (Becton Dickinson, U.S.A.). While no growth was detected in 120 (32.7%) of the clinical samples studied, in 144 samples (39.2%) only aerobes, in 28 (7.6%) only anaerobes and in 75 (20.5%) of the samples both aerobes and anaerobes were isolated. The number of the anaerobic isolates was 217 from 103 samples with anaerobic growth. Of these 103 samples 15 showed single bacterial growth whereas in 88 samples multiple bacterial isolates were detected. Anaerobic isolates consisted of 92 Gram negative bacilli (Bacteroides spp. 50, Prevotella spp. 14, Porphyromonas spp. 10, Fusobacterium spp. 7, Tisierella spp. 2, unidentified 9), 57 Gram positive bacilli (Clostridium spp.17, Propionibacterium spp. 16, Lactobacillus spp. 8, Actinomyces spp. 5, Eubacterium spp. 2, Bifidobacterium adolescentis 1, Mobiluncus mulieris 1, unidentified nonspore forming rods 7), 61 Gram positive cocci (anaerobic cocci 44, microaerophilic cocci 17), and 7 Gram negative cocci (Veillonella spp.). In conclusion, in the samples studied with prediagnosis of anaerobic infection, Bacteroides spp. (23%) were the most common bacteria followed by anaerobic Gram positive cocci (20.3%) and Clostridium spp (7.8%).
Classification of ductal carcinoma in situ by gene expression profiling
Hannemann, Juliane; Velds, Arno; Halfwerk, Johannes BG; Kreike, Bas; Peterse, Johannes L; van de Vijver, Marc J
2006-01-01
Introduction Ductal carcinoma in situ (DCIS) is characterised by the intraductal proliferation of malignant epithelial cells. Several histological classification systems have been developed, but assessing the histological type/grade of DCIS lesions is still challenging, making treatment decisions based on these features difficult. To obtain insight in the molecular basis of the development of different types of DCIS and its progression to invasive breast cancer, we have studied differences in gene expression between different types of DCIS and between DCIS and invasive breast carcinomas. Methods Gene expression profiling using microarray analysis has been performed on 40 in situ and 40 invasive breast cancer cases. Results DCIS cases were classified as well- (n = 6), intermediately (n = 18), and poorly (n = 14) differentiated type. Of the 40 invasive breast cancer samples, five samples were grade I, 11 samples were grade II, and 24 samples were grade III. Using two-dimensional hierarchical clustering, the basal-like type, ERB-B2 type, and the luminal-type tumours originally described for invasive breast cancer could also be identified in DCIS. Conclusion Using supervised classification, we identified a gene expression classifier of 35 genes, which differed between DCIS and invasive breast cancer; a classifier of 43 genes could be identified separating between well- and poorly differentiated DCIS samples. PMID:17069663
Amirhooshang, Alvandi; Ramin, Abiri; Ehsan, Aryan; Mansour, Rezaei; Shahram, Bagherabadi
2014-09-01
To gain a better understanding of transmission and selecting appropriate measures for preventing the spread of Helicobacter pylori, the aim of this study was to investigate the prevalence of H. pylori in drinking water samples in Kermanshah, Iran. Drinking water samples were collected from around Kermanshah and filtered through 0.45 μm nitrocellulose filters. The bacterial sediment was subjected to DNA extraction and polymerase chain reaction (PCR) for H. pylori detection using newly designed primers targeted at the conserved region of the ureC gene. The overall detection rates for H. pylori DNA in the water samples were 56% (66/118) with a frequency of 36% (25/70) in tap water samples and 85% (41/48) in wells. The detection limit was 50 bacteria per liter of filtered water and a pure H. pylori DNA copy number of 6 per reaction. Based on the evidence we may suggest that recontamination occurred and H. pylori entered into the water piping system through cracked or broken pipes or was released from established H. pylori biofilms on pipes. In conclusion, a high prevalence of H. pylori was detected in drinking water samples that strengthens the evidence of H. pylori transmission through drinking water.
List, Susan M; Starks, Nykole; Baum, John; Greene, Carmine; Pardo, Scott; Parkes, Joan L; Schachner, Holly C; Cuddihy, Robert
2011-01-01
Background This study evaluated performance and product labeling of CONTOUR® USB, a new blood glucose monitoring system (BGMS) with integrated diabetes management software and a universal serial bus (USB) port, in the hands of untrained lay users and health care professionals (HCPs). Method Subjects and HCPs tested subject's finger stick capillary blood in parallel using CONTOUR USB meters; deep finger stick blood was tested on a Yellow Springs Instruments (YSI) glucose analyzer for reference. Duplicate results by both subjects and HCPs were obtained to assess system precision. System accuracy was assessed according to International Organization for Standardization (ISO) 15197:2003 guidelines [within ±15 mg/dl of mean YSI results (samples <75 mg/dl) and ±20% (samples ≥75 mg/dl)]. Clinical accuracy was determined by Parkes error grid analysis. Subject labeling comprehension was assessed by HCP ratings of subject proficiency. Key system features and ease-of-use were evaluated by subject questionnaires. Results All subjects who completed the study (N = 74) successfully performed blood glucose measurements, connected the meter to a laptop computer, and used key features of the system. The system was accurate; 98.6% (146/148) of subject results and 96.6% (143/148) of HCP results exceeded ISO 15197:2003 criteria. All subject and HCP results were clinically accurate (97.3%; zone A) or associated with benign errors (2.7%; zone B). The majority of subjects rated features of the BGMS as “very good” or “excellent.” Conclusions CONTOUR USB exceeded ISO 15197:2003 system performance criteria in the hands of untrained lay users. Subjects understood the product labeling, found the system easy to use, and successfully performed blood glucose testing. PMID:22027308
Interoperability of Information Systems Managed and Used by the Local Health Departments
Leider, Jonathon P.; Luo, Huabin; Kaur, Ravneet
2016-01-01
Background: In the post-Affordable Care Act era marked by interorganizational collaborations and availability of large amounts of electronic data from other community partners, it is imperative to assess the interoperability of information systems used by the local health departments (LHDs). Objectives: To describe the level of interoperability of LHD information systems and identify factors associated with lack of interoperability. Data and Methods: This mixed-methods research uses data from the 2015 Informatics Capacity and Needs Assessment Survey, with a target population of all LHDs in the United States. A representative sample of 650 LHDs was drawn using a stratified random sampling design. A total of 324 completed responses were received (50% response rate). Qualitative data were used from a key informant interview study of LHD informatics staff from across the United States. Qualitative data were independently coded by 2 researchers and analyzed thematically. Survey data were cleaned, bivariate comparisons were conducted, and a multivariable logistic regression was run to characterize factors associated with interoperability. Results: For 30% of LHDs, no systems were interoperable, and 38% of LHD respondents indicated some of the systems were interoperable. Significant determinants of interoperability included LHDs having leadership support (adjusted odds ratio [AOR] = 3.54), control of information technology budget allocation (AOR = 2.48), control of data systems (AOR = 2.31), having a strategic plan for information systems (AOR = 1.92), and existence of business process analysis and redesign (AOR = 1.49). Conclusion: Interoperability of all systems may be an informatics goal, but only a small proportion of LHDs reported having interoperable systems, pointing to a substantial need among LHDs nationwide. PMID:27684616
The Metallicity of Void Dwarf Galaxies
NASA Astrophysics Data System (ADS)
Kreckel, K.; Croxall, K.; Groves, B.; van de Weygaert, R.; Pogge, R. W.
2015-01-01
The current ΛCDM cosmological model predicts that galaxy evolution proceeds more slowly in lower density environments, suggesting that voids are a prime location to search for relatively pristine galaxies that are representative of the building blocks of early massive galaxies. To test the assumption that void galaxies are more pristine, we compare the evolutionary properties of a sample of dwarf galaxies selected specifically to lie in voids with a sample of similar isolated dwarf galaxies in average density environments. We measure gas-phase oxygen abundances and gas fractions for eight dwarf galaxies (Mr > -16.2), carefully selected to reside within the lowest density environments of seven voids, and apply the same calibrations to existing samples of isolated dwarf galaxies. We find no significant difference between these void dwarf galaxies and the isolated dwarf galaxies, suggesting that dwarf galaxy chemical evolution proceeds independent of the large-scale environment. While this sample is too small to draw strong conclusions, it suggests that external gas accretion is playing a limited role in the chemical evolution of these systems, and that this evolution is instead dominated mainly by the internal secular processes that are linking the simultaneous growth and enrichment of these galaxies.
Exposure to airborne asbestos in thermal power plants in Mongolia
Damiran, Naransukh; Silbergeld, Ellen K; Frank, Arthur L; Lkhasuren, Oyuntogos; Ochir, Chimedsuren; Breysse, Patrick N
2015-01-01
Background: Coal-fired thermal power plants (TPPs) in Mongolia use various types of asbestos-containing materials (ACMs) in thermal insulation of piping systems, furnaces, and other products. Objective: To investigate the occupational exposure of insulation workers to airborne asbestos in Mongolian power plants. Methods: Forty-seven air samples were collected from four power plants in Mongolia during the progress of insulation work. The samples were analyzed by phase contrast microscopy (PCM) and transmission electron microscopy (TEM). Results: The average phase contrast microscopy equivalent (PCME) asbestos fiber concentration was 0.93 f/cm3. Sixteen of the 41 personal and one of the area samples exceeded the United States Occupational Safety and Health Administration (US OSHA) short-term exposure limit of 1.0 f/cm3. If it is assumed that the short-term samples collected are representative of full-shift exposure, then the exposures are approximately 10 times higher than the US OSHA 8-hour permissible exposure limit of 0.1 f/cm3. Conclusion: Power plant insulation workers are exposed to airborne asbestos at concentrations that exceed the US OSHA Permissible Exposure Limit. Action to mitigate the risks should be taken in Mongolia. PMID:25730489
Ha, Jihye; Han, Geum Hee; Kim, Myungsook; Lee, Kyungwon
2018-01-01
Background Early and appropriate antibiotic treatment improves the clinical outcome of patients with septicemia; therefore, reducing the turn-around time for identification (ID) and antimicrobial susceptibility test (AST) results is essential. We established a method for rapid ID and AST using short-term incubation of positive blood culture broth samples on solid media, and evaluated its performance relative to that of the conventional method using two rapid ID systems and a rapid AST method. Methods A total of 254 mono-microbial samples were included. Positive blood culture samples were incubated on blood agar plates for six hours and identified by the MicroFlex LT (Bruker Daltonics) and Vitek-MS (bioMeriéux) systems, followed by AST using the Vitek2 System (bioMeriéux). Results The correct species-level ID rates were 82.3% (209/254) and 78.3% (199/254) for the MicroFlex LT and Vitek-MS platforms, respectively. For the 1,174 microorganism/antimicrobial agent combinations tested, the rapid AST method showed total concordance of 97.8% (1,148/1,174) with the conventional method, with a very major error rate of 0.5%, major error rate of 0.7%, and minor error rate of 1.0%. Conclusions Routine implementation of this short-term incubation method could provide ID results on the day of blood culture-positivity detection and one day earlier than the conventional AST method. This simple method will be very useful for rapid ID and AST of bacteria from positive blood culture bottles in routine clinical practice. PMID:29401558
Bédard, Emilie; Lévesque, Simon; Martin, Philippe; Pinsonneault, Linda; Paranjape, Kiran; Lalancette, Cindy; Dolcé, Charles-Éric; Villion, Manuela; Valiquette, Louis; Faucher, Sébastien P; Prévost, Michèle
2016-12-01
OBJECTIVE To determine the source of a Legionella pneumophila serogroup 5 nosocomial outbreak and the role of the heat exchanger installed on the hot water system within the previous year. SETTING A 400-bed tertiary care university hospital in Sherbrooke, Canada. METHODS Hot water samples were collected and cultured for L. pneumophila from 25 taps (baths and sinks) within wing A and 9 taps in wing B. Biofilm (5) and 2 L water samples (3) were collected within the heat exchangers for L. pneumophila culture and detection of protists. Sequence-based typing was performed on strain DNA extracts and pulsed-field gel electrophoresis patterns were analyzed. RESULTS Following 2 cases of hospital-acquired legionellosis, the hot water system investigation revealed a large proportion of L. pneumophila serogroup 5 positive taps (22/25 in wing A and 5/9 in wing B). High positivity was also detected in the heat exchanger of wing A in water samples (3/3) and swabs from the heat exchanger (4/5). The outbreak genotyping investigation identified the hot water system as the source of infections. Genotyping results revealed that all isolated environmental strains harbored the same related pulsed-field gel electrophoresis pattern and sequence-based type. CONCLUSIONS Two cases of hospital-acquired legionellosis occurred in the year following the installation of a heat exchanger to preheat hospital hot water. No cases were reported previously, although the same L. pneumophila strain was isolated from the hot water system in 1995. The heat exchanger promoted L. pneumophila growth and may have contributed to confirmed clinical cases. Infect. Control Hosp. Epidemiol. 2016;1475-1480.
Social protection systems in vulnerable families: their importance for the public health
Arcos, Estela; Sanchez, Ximena; Toffoletto, Maria Cecilia; Baeza, Margarita; Gazmuri, Patricia; Muñoz, Luz Angélica; Vollrath, Antonia
2014-01-01
OBJECTIVE To analyze the effectiveness of the Chilean System of Childhood Welfare in transferring benefits to socially vulnerable families. METHODS A cross-sectional study with a sample of 132 families from the Metropolitan Region, Chile, stratified according to degree of social vulnerability, between September 2011 and January 2012. Semi-structured interviews were conducted with mothers of the studied families in public health facilities or their households. The variables studied were family structure, psychosocial risk in the family context and integrated benefits from the welfare system in families that fulfill the necessary requirements for transfer of benefits. Descriptive statistics to measure location and dispersion were calculated. A binary logistic regression, which accounts for the sample size of the study, was carried out. RESULTS The groups were homogenous regarding family size, the presence of biological father in the household, the number of relatives living in the same dwelling, income generation capacity and the rate of dependency and psychosocial risk (p ≥ 0.05). The transfer of benefits was low in all three groups of the sample (≤ 23.0%). The benefit with the best coverage in the system was the Single Family Subsidy, whose transfer was associated with the size of the family, the presence of relatives in the dwelling, the absence of the father in the household, a high rate of dependency and a high income generation capacity (p ≤ 0.10). CONCLUSIONS The effectiveness of benefit transfer was poor, especially in families that were extremely socially vulnerable. Further explanatory studies of benefit transfers to the vulnerable population, of differing intensity and duration, are required in order to reduce health disparities and inequalities. PMID:25119935
Alp, Alpaslan; Us, Dürdal; Hasçelik, Gülşen
2004-01-01
Rapid quantitative molecular methods are very important for the diagnosis of human immunodeficiency virus (HIV) infections, assessment of prognosis and follow up. The purpose of this study was to compare and evaluate the performances of conventional manual extraction method and automated MagNA Pure system, for the nucleic acid isolation step which is the first and most important step in molecular diagnosis of HIV infections. Plasma samples of 35 patients in which anti-HIV antibodies were found as positive by microparticule enzyme immunoassay and confirmed by immunoblotting method, were included in the study. The nucleic acids obtained simultaneously by manual isolation kit (Cobas Amplicor, HIV-1 Monitor Test, version 1.5, Roche Diagnostics) and automated system (MagNA Pure LC Total Nucleic Acid Isolation Kit, Roche Diagnostics), were amplified and detected in Cobas Amplicor (Roche Diagnostics) instrument. Twenty three of 35 samples (65.7%) were found to be positive, and 9 (25.7%) were negative by both of the methods. The agreement between the methods were detected as 91.4%, for qualitative results. Viral RNA copies detected by manual and MagNA Pure isolation methods were found between 76.0-7.590.000 (mean: 487.143) and 113.0-20.300.0000 (mean: 2.174.097) copies/ml, respectively. When both of the overall and individual results were evaluated, the number of RNA copies obtained with automatized system, were found higher than the manual method (p<0.05). Three samples which had low numbers of nucleic acids (113, 773, 857, respectively) with MagNA Pure, yielded negative results with manual method. In conclusion, the automatized MagNA Pure system was found to be a reliable, rapid and practical method for the isolation of HIV-RNA.
Sawmill simulation: concepts and computer use
Hugh W. Reynolds; Charles J. Gatchell
1969-01-01
Product specifications were fed into a computer so that the yield of products from the same sample of logs could be determined for simulated sawing methods. Since different sawing patterns were tested on the same sample, variation among log samples was eliminated; hence, the statistical conclusions are very precise.
Health Information Management System for Elderly Health Sector: A Qualitative Study in Iran
Sadoughi, Farahnaz; Shahi, Mehraban; Ahmadi, Maryam; Davaridolatabadi, Nasrin
2016-01-01
Background: There are increasing change and development of information in healthcare systems. Given the increase in aging population, managers are in need of true and timely information when making decision. Objectives: The aim of this study was to investigate the current status of the health information management system for the elderly health sector in Iran. Materials and Methods: This qualitative study was conducted in two steps. In the first step, required documents for administrative managers were collected using the data gathering form and observed and reviewed by the researcher. In the second step, using an interview guide, the required information was gathered through interviewing experts and faculty members. The convenience, purposeful and snowball sampling methods were applied to select interviewees and the sampling continued until reaching the data saturation point. Finally, notes and interviews were transcribed and content analysis was used to analyze them. Results: The results of the study showed that there was a health information management system for the elderly health sector in Iran. However, in all primary health care centers the documentation of data was done manually; the data flow was not automated; and the analysis and reporting of data are also manually. Eventually, decision makers are provided with delayed information. Conclusions: It is suggested that the steward of health in Iran, the ministry of health, develops an appropriate infrastructure and finally puts a high priority on the implementation of the health information management system for elderly health sector in Iran. PMID:27186383
Arkesteijn, Irene T M; Mouser, Vivian H M; Mwale, Fackson; van Dijk, Bart G M; Ito, Keita
2016-05-01
In vitro evaluation of nucleus pulposus (NP) tissue regeneration would be useful, but current systems for NP culture are not ideal for injections. The aim of this study was to develop a long-term culture system for NP tissue that allows injections of regenerative agents. Bovine caudal NPs were harvested and placed in the newly designed culture system. After equilibration of the tissue to 0.3 MPa the volume was fixed and the tissue was cultured for 28 days. The cell viability and extracellular matrix composition remained unchanged during the culture period and gene expression profiles were similar to those obtained in earlier studies. Furthermore, to test the responsiveness of bovine caudal NPs in the system, samples were cultured for 4 days and injected twice (day 1 and 3) with (1) PBS, (2) Link-N, for regeneration, and (3) TNF-α, for degeneration. It was shown that TNF-α increased COX2 gene expression, whereas no effect of Link-N was detected. In conclusion, the newly designed system allows long-term culture of NP tissue, wherein tissue reactions to injected stimulants can be observed.
Enzyme-based logic gates and circuits-analytical applications and interfacing with electronics.
Katz, Evgeny; Poghossian, Arshak; Schöning, Michael J
2017-01-01
The paper is an overview of enzyme-based logic gates and their short circuits, with specific examples of Boolean AND and OR gates, and concatenated logic gates composed of multi-step enzyme-biocatalyzed reactions. Noise formation in the biocatalytic reactions and its decrease by adding a "filter" system, converting convex to sigmoid response function, are discussed. Despite the fact that the enzyme-based logic gates are primarily considered as components of future biomolecular computing systems, their biosensing applications are promising for immediate practical use. Analytical use of the enzyme logic systems in biomedical and forensic applications is discussed and exemplified with the logic analysis of biomarkers of various injuries, e.g., liver injury, and with analysis of biomarkers characteristic of different ethnicity found in blood samples on a crime scene. Interfacing of enzyme logic systems with modified electrodes and semiconductor devices is discussed, giving particular attention to the interfaces functionalized with signal-responsive materials. Future perspectives in the design of the biomolecular logic systems and their applications are discussed in the conclusion. Graphical Abstract Various applications and signal-transduction methods are reviewed for enzyme-based logic systems.
Munro, Peter R.T.; Ignatyev, Konstantin; Speller, Robert D.; Olivo, Alessandro
2013-01-01
X-ray phase contrast imaging is a very promising technique which may lead to significant advancements in medical imaging. One of the impediments to the clinical implementation of the technique is the general requirement to have an x-ray source of high coherence. The radiation physics group at UCL is currently developing an x-ray phase contrast imaging technique which works with laboratory x-ray sources. Validation of the system requires extensive modelling of relatively large samples of tissue. To aid this, we have undertaken a study of when geometrical optics may be employed to model the system in order to avoid the need to perform a computationally expensive wave optics calculation. In this paper, we derive the relationship between the geometrical and wave optics model for our system imaging an infinite cylinder. From this model we are able to draw conclusions regarding the general applicability of the geometrical optics approximation. PMID:20389424
Munro, Peter R T; Ignatyev, Konstantin; Speller, Robert D; Olivo, Alessandro
2010-03-01
X-ray phase contrast imaging is a very promising technique which may lead to significant advancements in medical imaging. One of the impediments to the clinical implementation of the technique is the general requirement to have an x-ray source of high coherence. The radiation physics group at UCL is currently developing an x-ray phase contrast imaging technique which works with laboratory x-ray sources. Validation of the system requires extensive modelling of relatively large samples of tissue. To aid this, we have undertaken a study of when geometrical optics may be employed to model the system in order to avoid the need to perform a computationally expensive wave optics calculation. In this paper, we derive the relationship between the geometrical and wave optics model for our system imaging an infinite cylinder. From this model we are able to draw conclusions regarding the general applicability of the geometrical optics approximation.
Predictors of Tobacco Use Among New York State Addiction Treatment Patients.
Guydish, Joseph; Yu, Jiang; Le, Thao; Pagano, Anna; Delucchi, Kevin
2015-01-01
Objectives. We used admissions data from the New York State addiction treatment system to assess patient self-reported tobacco use and factors associated with tobacco use. Methods. We compared prevalence of tobacco use in the state addiction treatment system with that of a national sample of people receiving addiction treatment and with that of the New York general population in 2005 to 2008. A random effects logistic model assessed relationships between patient- and program-level variables and tobacco use. Results. Prevalence of tobacco use in the New York treatment system was similar to that in national addiction treatment data and was 3 to 4 times higher than that in the general population. Co-occurring mental illness, opiate use, methadone treatment, and being a child of a substance-abusing parent were associated with higher rates of tobacco use. Conclusions. We call on federal leadership to build capacity to address tobacco use in addiction treatment, and we call on state leadership to implement tobacco-free grounds policies in addiction treatment systems.
Warm debris disks candidates in transiting planets systems
NASA Astrophysics Data System (ADS)
Ribas, Á.; Merín, B.; Ardila, D. R.; Bouy, H.
2012-05-01
We have bandmerged candidate transiting planetary systems (from the Kepler satellite) and confirmed transiting planetary systems (from the literature) with the recent Wide-field Infrared Survey Explorer (WISE) preliminary release catalog. We have found 13 stars showing infrared excesses at either 12 μm and/or 22 μm. Without longer wavelength observations it is not possible to conclusively determine the nature of the excesses, although we argue that they are likely due to debris disks around the stars. If confirmed, our sample ~doubles the number of currently known warm excess disks around old main sequence stars. The ratios between the measured fluxes and the stellar photospheres are generally larger than expected for Gyr-old stars, such as these planetary hosts. Assuming temperature limits for the dust and emission from large dust particles, we derive estimates for the disk radii. These values are comparable to the planet's semi-major axis, suggesting that the planets may be stirring the planetesimals in the system.
Predictors of Tobacco Use Among New York State Addiction Treatment Patients
Yu, Jiang; Pagano, Anna; Delucchi, Kevin
2015-01-01
Objectives. We used admissions data from the New York State addiction treatment system to assess patient self-reported tobacco use and factors associated with tobacco use. Methods. We compared prevalence of tobacco use in the state addiction treatment system with that of a national sample of people receiving addiction treatment and with that of the New York general population in 2005 to 2008. A random effects logistic model assessed relationships between patient- and program-level variables and tobacco use. Results. Prevalence of tobacco use in the New York treatment system was similar to that in national addiction treatment data and was 3 to 4 times higher than that in the general population. Co-occurring mental illness, opiate use, methadone treatment, and being a child of a substance-abusing parent were associated with higher rates of tobacco use. Conclusions. We call on federal leadership to build capacity to address tobacco use in addiction treatment, and we call on state leadership to implement tobacco-free grounds policies in addiction treatment systems. PMID:25393179
Milsted, Andrew J.; Hale, Jennifer R.; Frey, Jeremy G.; Neylon, Cameron
2013-01-01
Background The electronic laboratory notebook (ELN) has the potential to replace the paper notebook with a marked-up digital record that can be searched and shared. However, it is a challenge to achieve these benefits without losing the usability and flexibility of traditional paper notebooks. We investigate a blog-based platform that addresses the issues associated with the development of a flexible system for recording scientific research. Methodology/Principal Findings We chose a blog-based approach with the journal characteristics of traditional notebooks in mind, recognizing the potential for linking together procedures, materials, samples, observations, data, and analysis reports. We implemented the LabTrove blog system as a server process written in PHP, using a MySQL database to persist posts and other research objects. We incorporated a metadata framework that is both extensible and flexible while promoting consistency and structure where appropriate. Our experience thus far is that LabTrove is capable of providing a successful electronic laboratory recording system. Conclusions/Significance LabTrove implements a one-item one-post system, which enables us to uniquely identify each element of the research record, such as data, samples, and protocols. This unique association between a post and a research element affords advantages for monitoring the use of materials and samples and for inspecting research processes. The combination of the one-item one-post system, consistent metadata, and full-text search provides us with a much more effective record than a paper notebook. The LabTrove approach provides a route towards reconciling the tensions and challenges that lie ahead in working towards the long-term goals for ELNs. LabTrove, an electronic laboratory notebook (ELN) system from the Smart Research Framework, based on a blog-type framework with full access control, facilitates the scientific experimental recording requirements for reproducibility, reuse, repurposing, and redeployment. PMID:23935832
Stability of the prosthetic screws of three types of craniofacial prostheses retention systems
2016-01-01
Objectives This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. Materials and Methods Twelve models of acrylic resin were used with implants placed 20 mm from each other and separated into three groups: (1) bar-clip (Sistema INP, São Paulo, Brazil), (2) ball/O-ring (Sistema INP), and (3) magnet (Metalmag, São Paulo, Brazil), with four samples in each group. Each sample underwent a mechanical cycling removal and insertion test (f=0.5 Hz) to determine the torque and the detorque values of the retention screws. A servo-hydraulic MTS machine (810-Flextest 40; MTS Systems, Eden Prairie, MN, USA) was used to perform the cycling with 2.5 mm and a displacement of 10 mm/s. The screws of the retention systems received an initial torque of 30 Ncm and the torque values required for loosening the screw values were obtained in three cycles (1,080, 2,160, and 3,240). The screws were retorqued to 30 Ncm before each new cycle. Results The sample was composed of 24 screws grouped as follows: bar-clip (n=8), ball/O-ring (n=8), and magnet (n=8). There were significant differences between the groups, with greater detorque values observed in the ball/O-ring group when compared to the bar-clip and magnet groups for the first cycle. However, the detorque value was greater in the bar-clip group for the second cycle. Conclusion The results of this study indicate that all prosthetic screws will loosen slightly after an initial tightening torque, also the bar-clip retention system demonstrated greater loosening of the screws when compared with ball/O-ring and magnet retention systems. PMID:28053905
Discrimination and Mental Health–Related Service Use in a National Study of Asian Americans
Chen, Juan; Gee, Gilbert C.; Fabian, Cathryn G.; Takeuchi, David T.
2010-01-01
Objectives. We examined the association between perceived discrimination and use of mental health services among a national sample of Asian Americans. Methods. Our data came from the National Latino and Asian American Study, the first national survey of Asian Americans. Our sample included 600 Chinese, 508 Filipinos, 520 Vietnamese, and 467 other Asians (n=2095). We used logistic regression to examine the association between discrimination and formal and informal service use and the interactive effect of discrimination and English language proficiency. Results. Perceived discrimination was associated with more use of informal services, but not with less use of formal services. Additionally, higher levels of perceived discrimination combined with lower English proficiency were associated with more use of informal services. Conclusions. The effect of perceived discrimination and language proficiency on service use indicates a need for more bilingual services and more collaborations between formal service systems and community resources. PMID:20299649
Saiki, M.K.; Jennings, M.R.; Hamilton, S.J.; Dinar, A.; Zilberman, D.
1991-01-01
Concentrations of total selenium were measured in whole-body samples of seven fishes from the Sacramento and San Joaquin River systems and the San Francisco Bay complex. Concentrations of selenium (up to 11 µg/g dry weight in whole-body composite samples) were highest in fish from canals and sloughs in the Grassland Water District (Grasslands) that received large inflows of subsurface agricultural drainage water. Slightly lower selenium concentrations occurred in fish from the San Joaquin River immediately downstream from tributaries draining the Grasslands. Although circumstantial evidence suggests that selenium-sensitive species such as bluegills and largemouth bass are being excluded from the Grasslands, conclusive evidence of selenium toxicity is still lacking. In response to earlier reports of high concentrations of selenium in several species collected from the Grasslands, the California Department of Health Services has urged people to limit consumption of fish from this region.
Reactivity of Free Malondialdehyde during In Vitro Simulated Gastrointestinal Digestion.
Vandemoortele, Angelique; Babat, Pinar; Yakubu, Mariam; De Meulenaer, Bruno
2017-03-15
An aqueous buffer, a saturated glycerol triheptanoate oil, and a Tween 20 stabilized fully hydrogenated coconut oil-in-water emulsion, all spiked with malondialdehyde, were subjected to in vitro digestion. A dynamic equilibrium between malondialdehyde, its aldol self-condensation products, and its hydrolytic cleavage products was observed. This equilibrium depended upon the kind of sample and the temperature at which these samples were preincubated during 24 h. The presence of oil during gastric digestion protected the aldol self-condensation and cleavage products from conversion to malondialdehyde, which occurred in the aqueous acidic gastric chyme. In parallel, the presence of oil enhanced the reactivity of malondialdehyde throughout the gastrointestinal digestion process. Malondialdehyde recoveries after digestion varied between 42 and 90%, depending upon the model system studied, with the aldol self-condensation as the main reaction pathway. In conclusion, this study revealed that malondialdehyde is a very reactive molecule whose reactivity does not stop at the point of ingestion.
PlantDB – a versatile database for managing plant research
Exner, Vivien; Hirsch-Hoffmann, Matthias; Gruissem, Wilhelm; Hennig, Lars
2008-01-01
Background Research in plant science laboratories often involves usage of many different species, cultivars, ecotypes, mutants, alleles or transgenic lines. This creates a great challenge to keep track of the identity of experimental plants and stored samples or seeds. Results Here, we describe PlantDB – a Microsoft® Office Access database – with a user-friendly front-end for managing information relevant for experimental plants. PlantDB can hold information about plants of different species, cultivars or genetic composition. Introduction of a concise identifier system allows easy generation of pedigree trees. In addition, all information about any experimental plant – from growth conditions and dates over extracted samples such as RNA to files containing images of the plants – can be linked unequivocally. Conclusion We have been using PlantDB for several years in our laboratory and found that it greatly facilitates access to relevant information. PMID:18182106
A systematic review of the quality of homeopathic clinical trials
Jonas, Wayne B; Anderson, Rachel L; Crawford, Cindy C; Lyons, John S
2001-01-01
Background While a number of reviews of homeopathic clinical trials have been done, all have used methods dependent on allopathic diagnostic classifications foreign to homeopathic practice. In addition, no review has used established and validated quality criteria allowing direct comparison of the allopathic and homeopathic literature. Methods In a systematic review, we compared the quality of clinical-trial research in homeopathy to a sample of research on conventional therapies using a validated and system-neutral approach. All clinical trials on homeopathic treatments with parallel treatment groups published between 1945–1995 in English were selected. All were evaluated with an established set of 33 validity criteria previously validated on a broad range of health interventions across differing medical systems. Criteria covered statistical conclusion, internal, construct and external validity. Reliability of criteria application is greater than 0.95. Results 59 studies met the inclusion criteria. Of these, 79% were from peer-reviewed journals, 29% used a placebo control, 51% used random assignment, and 86% failed to consider potentially confounding variables. The main validity problems were in measurement where 96% did not report the proportion of subjects screened, and 64% did not report attrition rate. 17% of subjects dropped out in studies where this was reported. There was practically no replication of or overlap in the conditions studied and most studies were relatively small and done at a single-site. Compared to research on conventional therapies the overall quality of studies in homeopathy was worse and only slightly improved in more recent years. Conclusions Clinical homeopathic research is clearly in its infancy with most studies using poor sampling and measurement techniques, few subjects, single sites and no replication. Many of these problems are correctable even within a "holistic" paradigm given sufficient research expertise, support and methods. PMID:11801202
NASA Astrophysics Data System (ADS)
Dirilgen, Tara; Juceviča, Edite; Melecis, Viesturs; Querner, Pascal; Bolger, Thomas
2018-01-01
The relative importance of niche separation, non-equilibrial and neutral models of community assembly has been a theme in community ecology for many decades with none appearing to be applicable under all circumstances. In this study, Collembola species abundances were recorded over eleven consecutive years in a spatially explicit grid and used to examine (i) whether observed beta diversity differed from that expected under conditions of neutrality, (ii) whether sampling points differed in their relative contributions to overall beta diversity, and (iii) the number of samples required to provide comparable estimates of species richness across three forest sites. Neutrality could not be rejected for 26 of the forest by year combinations. However, there is a trend toward greater structure in the oldest forest, where beta diversity was greater than predicted by neutrality on five of the eleven sampling dates. The lack of difference in individual- and sample-based rarefaction curves also suggests randomness in the system at this particular scale of investigation. It seems that Collembola communities are not spatially aggregated and assembly is driven primarily by neutral processes particularly in the younger two sites. Whether this finding is due to small sample size or unaccounted for environmental variables cannot be determined. Variability between dates and sites illustrates the potential of drawing incorrect conclusions if data are collected at a single site and a single point in time.
Koukos, Georgios; Konstantinidis, Antonios; Tsalikis, Lazaros; Arsenakis, Minas; Slini, Theodora; Sakellari, Dimitra
2016-01-01
Objectives: The aim of this study is to investigate the prevalence of blaTEM and nim genes that encode resistance to β-lactams and nitroimidazoles, respectively, in the oral cavity of systemically healthy Greek subjects. Materials and Methodology: After screening 720 potentially eligible subjects, 154 subjects were recruited for the study, including 50 periodontally healthy patients, 52 cases of gingivitis and 52 cases of chronic periodontitis. The clinical parameters were assessed with an automated probe. Various samples were collected from the tongue, first molars and pockets >6mm, and analysed by polymerase chain reaction-amplification of the blaTEM and nim genes, using primers and conditions previously described in the literature. Results: There was a high rate of detection of blaTEM in plaque and tongue samples alike in all periodontal conditions (37% of plaque and 60% of tongue samples, and 71% of participants). The blaTEM gene was detected more frequently in the tongue samples of the periodontally healthy (56%) and chronic periodontitis (62%) groups compared to the plaque samples from the same groups (36% and 29%, respectively; z-test with Bonferroni corrections-tests, P<0.05). The nim gene was not detected in any of the 343 samples analysed. Conclusion: The oral cavity of Greek subjects often harbours blaTEM but not nim genes, and therefore the antimicrobial activity of β-lactams might be compromised. PMID:27099637
Examination of Pre-Productions Samples of UOP IONSIV(R) IE-910 and IE-911
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, D.D.
2001-07-10
This report includes results of the extensive examination of newly-prepared laboratory-scale and pre-production samples of caustic-washed CST [crystalline silicotitanate] as compared to similar performance data for commercially-available and baseline samples. Conclusions from this work include the following.
Enko, Dietmar; Mangge, Harald; Münch, Andreas; Niedrist, Tobias; Mahla, Elisabeth; Metzler, Helfried; Prüller, Florian
2017-01-01
Introduction The aim of this study was to assess pneumatic tube system (PTS) alteration on platelet function by the light transmission aggregometry (LTA) and whole blood aggregometry (WBA) method, and on the results of platelet count, prothrombin time (PT), activated partial thromboplastin time (APTT), and fibrinogen. Materials and methods Venous blood was collected into six 4.5 mL VACUETTE® 9NC coagulation sodium citrate 3.8% tubes (Greiner Bio-One International GmbH, Kremsmünster, Austria) from 49 intensive care unit (ICU) patients on dual anti-platelet therapy and immediately hand carried to the central laboratory. Blood samples were divided into 2 Groups: Group 1 samples (N = 49) underwent PTS (4 m/s) transport from the central laboratory to the distant laboratory and back to the central laboratory, whereas Group 2 samples (N = 49) were excluded from PTS forces. In both groups, LTA and WBA stimulated with collagen, adenosine-5’-diphosphate (ADP), arachidonic acid (AA) and thrombin-receptor-activated-peptide 6 (TRAP-6) as well as platelet count, PT, APTT, and fibrinogen were performed. Results No statistically significant differences were observed between blood samples with (Group 1) and without (Group 2) PTS transport (P values from 0.064 – 0.968). The AA-induced LTA (bias: 68.57%) exceeded the bias acceptance limit of ≤ 25%. Conclusions Blood sample transportation with computer controlled PTS in our hospital had no statistically significant effects on platelet aggregation determined in patients with anti-platelet therapy. Although AA induced LTA showed a significant bias, the diagnostic accuracy was not influenced. PMID:28392742
Assunção, Cristiane Meira; Goulart, Marcelo; Essvein, Tattiana Enrich; dos Santos, Nicole Marchioro; Erhardt, Maria Carolina Guilherme; Lussi, Adrian; Rodrigues, Jonas de Almeida
2018-01-01
ABSTRACT Objective To evaluate the effect of erosive challenges on the tooth- restoration interface of deciduous teeth treated with different adhesive protocols. Material and Methods Deciduous molars were cut mesiodistally, then embedded, abraded and polished (n=80). Samples were randomly divided according to the adhesive system used into: G1 (Adper Single Bond2®, etch-and-rinse), G2 (Universal Single Bond®, self-etching), G3 (OptibondFL®, etch-and-rinse with Fluoride) and G4 (BondForce®, self-etching with Fluoride). After standardized cavity preparation (2 mm diameter x 2 mm depth), adhesive systems were applied and samples were restored (composite resin Z350®). Half of the samples were exposed to erosive/abrasive cycles (n = 10, each adhesive group), and the other half (control group; n = 10) remained immersed in artificial saliva. For microleakage analysis, samples were submersed in methylene blue and analyzed at 40x magnifications. Cross-sectional microhardness (CSMH) was carried out (50 g/5 s) at 25 μm, 50 μm, and 100 μm from the eroded surface and at 25 μm, 75 μm, and 125 μm from the enamel bond interface. Results Regarding microleakage, 7.5% of the samples showed no dye infiltration, 30% showed dye infiltration only at the enamel interface, and 62.5% showed dye infiltration through the dentin-enamel junction, with no difference between groups (p≥0.05). No significant difference was observed in CSMH at different depths (two-way ANOVA, p≥0.05). Conclusions We did not observe significant changes in microleakage or CSMH after erosive/abrasive challenges in deciduous teeth treated with different adhesive protocols (etch-and-rinse and self-etching adhesives, with and without fluoride). PMID:29364339
Price, Richard W; Parham, Robin; Lu, Jing; Wring, Stephen A.; Baker, Brian; Sailstad, Jeff; Hoh, Rebecca; Liegler, Teri; Spudich, Serena; Kuritzkes, Daniel R; Deeks, Steven G
2009-01-01
Background Enfuvirtide is a potent inhibitor of systemic HIV-1 replication, but its penetration into the human central nervous system (CNS) has not been analyzed. Here, we define cerebrospinal fluid (CSF) enfuvirtide pharmacokinetics and present a case illustrating the use of enfuvirtide as a probe to trace the origins of CSF HIV-1 quasispecies. Methods Enfuvirtide CSF PK was assessed in 18 CSF and plasma sample pairs from 4 HIV-1-infected subjects. Enfuvirtide levels were measured by liquid chromatography tandem mass spectrometry using known standards and controls that including spiked CSF samples from untreated, HIV-negative subjects. A segment of the gp41-coding region encompassing the heptad repeat (HR)-1 and HR-2 domains was amplified from selected CSF and plasma samples, and independent clones sequenced to assess resistance-associated mutations. Results CSF and plasma samples obtained between 2 and 20 hrs after enfuvirtide injection showed plasma concentrations similar to previous reports (mean 3.687 +/−1.828 µg/ml SD) with prolonged decay. By contrast, enfuvirtide in all CSF samples was below the assay detection limit of 0.025 µg/ml. In one subject, who developed a transient increase in CSF HIV-1 RNA, 7 of 7 CSF and plasma clones had identical enfuvirtide resistance-associated V38A mutation, suggesting that the CSF quasispecies derived from that of blood. Conclusions Enfuvirtide CSF penetration into CSF is negligible, and thus in clinical settings where direct CNS drug exposure is critical, this drug will likely not directly contribute to the local therapeutic effect. Enfuvirtide can be used as a tool to dissect the origin of the CNS virus. PMID:18572749
Leachability of Arsenic (As) Contaminated Landfill Soil Stabilised by Cement and Bagasse Ash
NASA Astrophysics Data System (ADS)
Azhar, A. T. S.; Azim, M. A. M.; Aziman, M.; Nabila, A. T. A.
2016-11-01
Contaminated soil with heavy metals, especially Arsenic (As) has become a major issue worldwide. As is reported to be a metal that affects human health and is related to have caused serious diseases that interrupts the nervous system, blood vessels and kidneys. However, proper treatment techniques such as Stabilization/Solidification (S/S) method can be employed and is capable of controlling these heavy metals from contaminating the soil strata and groundwater resources. This study is to investigate the leachability of Arsenic (As) in S/S method when bagasse ash (BA) is added to remedy contaminated Landfill soil. Cement is added at a proportion of 5%, 10%, 15% and 20% in sample weights without BA while in another sample; the cement replaces BA at a proportion of 2.5%, 5%, 7.5%. and 10%. All samples were allowed to harden and cured at room temperature for 7, 14 and 28 days. The effectiveness of the treatment was assessed by conducting Synthetic Precipitation Leaching Procedure (SPLP). Results indicate that pH and leachability are found to have major influence on metal release. The final pH after leaching tests showed improvements especially samples containing BA. In addition, the concentration of As in the SPLP test after the curing period of 28 days were detected to be below the leachability limit as regulated by WHO's Guidelines for Drinking-water Quality. As a whole, the results obtained from testing showed that sample containing 10% cement with 10% BA is the most effective and is the optimum mix since this proportion succeeded in minimising the leachability of As at total reduction by 100%, In conclusion, partial replacement of cement with BA in the binder system has been successful in reducing the leachability.
2013-01-01
Background Siwu decoction categorized formulae (SWDCF) are widely used for treating gynecological diseases. This study aims to elucidate the differences of bioactive constituents in SWDCF by ultra-high performance liquid chromatography coupled with time-of-flight mass spectrometry (UPLC - QTOF - MS /MS) and HPLC-DAD. Methods An efficient method based on UPLC - QTOF - MS /MS was developed for identifying the chemical profiles of SWDCF. HPLC-DAD method was used for quantifying seven chemical markers in SWDCF. Results Eighty four components were identified or characterized, including ten organic acids, thirty glycosides (monoterpene or iridoid or phenylpropanoids glycosides), fourteen lactones, eighteen flavonoids, and eleven alkaloids in the complex system. The datasets of tR-m/z pairs, ion intensities and sample codes were processed with supervised orthogonal partial least squared discriminant analysis to compare these decoction samples. After a clear classification was established, OPLS-DA was performed and 16 common components with relative quantity in SWDCF samples were determined. Gallic acid, protocatechuic acid, vanillic acid, caffeic acid, paeoniflorin, ferulic acid, and senkyunolide I were selected as the chemical markers to identify SWDCF by HPLC-DAD. Conclusion The chemical profiles with 84 components in SWDCF, including monoterpene glycosides, acetophenones, galloyl glucoses, even some isomers in the complex system were characterized by UPLC–QTOF–MS/MS. PMID:23453004
Juhnke, Christin; Mühlbacher, Axel C.
2013-01-01
Introduction Patient-centred healthcare is becoming a more significant success factor in the design of integrated healthcare systems. The objective of this study is to structure a patient-relevant hierarchy of needs and expectations for the design of organised healthcare delivery systems. Methods A questionnaire with 84 items was conducted with N = 254 healthcare experts and N = 670 patients. Factor analyses were performed using SPSS©18. The number of factors retained was controlled by Kaiser's criterion, validation of screeplots and interpretability of the items. Cronbach's α was used to assess the internal consistency of the subscales. Results Exploratory factor analysis led to 24 factors in the expert sample and 20 in the patient sample. After analysing the screeplots, confirmatory factor analyses were computed for 7-factor solutions accounting for 42.963% of the total variance and Kaiser–Meyer–Olkin of 0.914 for the patients (experts: 38.427%, Kaiser–Meyer–Olkin = 0.797). Cronbach's α ranged between 0.899 and 0.756. Based on the analysis, coordinated care could be differentiated into seven dimensions: access, data and information, service and infrastructure, professional care, interpersonal care, individualised care, continuity and coordination. Conclusion and Discussion The study provides insight into patient and experts expectations towards the organisation of integrated healthcare delivery systems. If providers and payers can take into account patient needs and expectations while implementing innovative healthcare delivery systems, greater acceptance and satisfaction will be achieved. In the best case, this will lead to better adherence resulting in better clinical outcomes. PMID:24363639
Patzke, Juergen; Budde, Ulrich; Huber, Andreas; Méndez, Adriana; Muth, Heidrun; Obser, Tobias; Peerschke, Ellinor; Wilkens, Matthias; Schneppenheim, Reinhard
2014-12-01
The functional activity of von Willebrand factor (VWF) is most frequently measured by using the ristocetin cofactor assay (VWF:RCo). However, the method's drawbacks include unsatisfactory precision, sensitivity and availability of automated system applications. We have developed an alternative assay (INNOVANCE VWF Ac) that is based on the binding of VWF to recombinant glycoprotein Ib (GPIb). Two gain-of-function mutations were introduced into a GPIb fragment, allowing an assay format without ristocetin. Fully automated assay applications are available for the BCS/BCS XP systems and the Sysmex CS-2000i, Sysmex CA-7000, Sysmex CA-1500 and Sysmex CA-560 systems.The INNOVANCE VWF Ac assay measuring range extends from 4 to 600% VWF for all systems except the Sysmex CA-560 system. Within-device precision values were found to be between 2 and 7%. The limit of detection was below 2.2% VWF. In a study on the BCS XP system, a total number of 580 sample results yielded a correlation to the VWF:RCo assay of r equal to 0.99 (slope = 0.96). Very similar results were observed when von Willebrand disease samples type 1, 2A, 2B, 2M, 2N and 3 were investigated with the new assay and the VWF:RCo assay. The excellent performance data and comparability to VWF:RCo, together with the ease of use, led us to the conclusion that the ristocetin cofactor assay can be replaced by the new GPIb-binding assay to reliably diagnosing patients with von Willebrand disease.
Molecular prey identification in Central European piscivores.
Thalinger, Bettina; Oehm, Johannes; Mayr, Hannes; Obwexer, Armin; Zeisler, Christiane; Traugott, Michael
2016-01-01
Diet analysis is an important aspect when investigating the ecology of fish-eating animals and essential for assessing their functional role in food webs across aquatic and terrestrial ecosystems. The identification of fish remains in dietary samples, however, can be time-consuming and unsatisfying using conventional morphological analysis of prey remains. Here, we present a two-step multiplex PCR system, comprised of six assays, allowing for rapid, sensitive and specific detection of fish DNA in dietary samples. This approach encompasses 78 fish and lamprey species native to Central European freshwaters and enables the identification of 31 species, six genera, two families, two orders and two fish family clusters. All targeted taxa were successfully amplified from 25 template molecules, and each assay was specific when tested against a wide range of invertebrates and vertebrates inhabiting aquatic environments. The applicability of the multiplex PCR system was evaluated in a feeding trial, wherein it outperformed morphological prey analysis regarding species-specific prey identification in faeces of Eurasian otters. Additionally, a wide spectrum of fish species was detected in field-collected faecal samples and regurgitated pellets of Common Kingfishers and Great Cormorants, demonstrating the broad applicability of the approach. In conclusion, this multiplex PCR system provides an efficient, easy to use and cost-effective tool for assessing the trophic ecology of piscivores in Central Europe. Furthermore, the multiplex PCRs and the primers described therein will be applicable wherever DNA of the targeted fish species needs to be detected at high sensitivity and specificity. © 2015 The Authors. Molecular Ecology Resources Published by John Wiley & Sons Ltd.
Bridges, Ana J.; Andrews, Arthur R.; Deen, Tisha L.
2014-01-01
Purpose This study assessed mental health needs and service utilization patterns in a convenience sample of Hispanic immigrants. Design and Method A total of 84 adult Hispanic participants completed a structured diagnostic interview and a semistructured service utilization interview with trained bilingual research assistants. Results In the sample, 36% met diagnostic criteria for at least one mental disorder. Although 42% of the sample saw a physician in the prior year, mental health services were being rendered primarily by religious leaders. The most common barriers to service utilization were cost (59%), lack of health insurance (35%), and language (31%). Although more women than men met criteria for a disorder, service utilization rates were comparable. Participants with a mental disorder were significantly more likely to have sought medical, but not psychiatric, services in the prior year and faced significantly more cost barriers than participants without a mental disorder. Conclusions Findings suggest that Hispanic immigrants, particularly those with a mental illness, need to access services but face numerous systemic barriers. The authors recommend specific ways to make services more affordable and linguistically accessible. PMID:22802297
NASA Astrophysics Data System (ADS)
Zhao, Liyun; Zhou, Jin; Wu, Quanjun
2016-01-01
This paper considers the sampled-data synchronisation problems of coupled harmonic oscillators with communication and input delays subject to controller failure. A synchronisation protocol is proposed for such oscillator systems over directed network topology, and then some general algebraic criteria on exponential convergence for the proposed protocol are established. The main features of the present investigation include: (1) both the communication and input delays are simultaneously addressed, and the directed network topology is firstly considered and (2) the effects of time delays on synchronisation performance are theoretically and numerically investigated. It is shown that in the absence of communication delays, coupled harmonic oscillators can achieve synchronisation oscillatory motion. Whereas if communication delays are nonzero at infinite multiple sampled-data instants, its synchronisation (or consensus) state is zero. This conclusion can be used as an effective control strategy to stabilise coupled harmonic oscillators in practical applications. Furthermore, it is interesting to find that increasing either communication or input delays will enhance the synchronisation performance of coupled harmonic oscillators. Subsequently, numerical examples illustrate and visualise theoretical results.
Jakopanec, Irena; Borgen, Katrine; Vold, Line; Lund, Helge; Forseth, Tore; Hannula, Raisa; Nygård, Karin
2008-01-01
Background On 7 May 2007 the medical officer in Røros (population 5600) reported 15 patients with gastroenteritis. Three days later he estimated hundreds being ill. Untreated tap water from a groundwater source was suspected as the vehicle and chlorination was started 11 May. Campylobacter was isolated from patients' stool samples. We conducted an investigation to identify the source and describe the extent of the outbreak. Methods We undertook a retrospective cohort study among a random sample of customers of Røros and neighbouring Holtålen waterworks. Holtålen, which has a different water source, was used as a control city. We conducted telephone interviews to gather data on illness from all household members. One randomly selected household member was asked about detailed exposure history. The regional hospital laboratory tested patients' stools for enteropathogens. Campylobacter isolates were typed by AFLP for genetic similarity at the Norwegian Institute of Public Health. Local authorities conducted the environmental investigation. Results We identified 105 cases among 340 individuals from Røros and Holtålen (Attack Rate = 31%). Tap water consumption was the only exposure associated with illness. Among randomly selected household members from Røros, a dose-response relationship was observed in daily consumed glasses of tap water (χ2 for trend = 8.1, p = 0.004). Campylobacter with identical AFLP was isolated from 25 out of 26 submitted stool samples. No pathogens were detected in water samples. We identified several events that might have caused pressure fall and influx of contaminated water into the water distribution system. On two occasions, pressure fall was noticed and parts of the distribution system were outdated. Conclusion The investigation confirmed a waterborne outbreak of campylobacteriosis in Røros. Although no single event was identified as the cause of contamination, this outbreak illustrates the vulnerability of water distribution systems. Good quality source water alone is not enough to ensure water safety. For a better risk management, more focus should be put on the distribution system security. Waterworks personnel should monitor the pressure regularly; reduce the leakage by upgrading the distribution network and use chlorination when conducting maintenance work. PMID:18816387
Miller, Ruth R; Uyaguari-Diaz, Miguel; McCabe, Mark N; Montoya, Vincent; Gardy, Jennifer L; Parker, Shoshana; Steiner, Theodore; Hsiao, William; Nesbitt, Matthew J; Tang, Patrick; Patrick, David M
2016-01-01
Myalgic Encephalomyelitis/Chronic Fatigue Syndrome (ME/CFS) is a debilitating disease causing indefinite fatigue. ME/CFS has long been hypothesised to have an infectious cause; however, no specific infectious agent has been identified. We used metagenomics to analyse the RNA from plasma samples from 25 individuals with ME/CFS and compare their microbial content to technical controls as well as three control groups: individuals with alternatively diagnosed chronic Lyme syndrome (N = 13), systemic lupus erythematosus (N = 11), and healthy controls (N = 25). We found that the majority of sequencing reads were removed during host subtraction, thus there was very low microbial RNA content in the plasma. The effects of sample batching and contamination during sample processing proved to outweigh the effects of study group on microbial RNA content, as the few differences in bacterial or viral RNA abundance we did observe between study groups were most likely caused by contamination and batch effects. Our results highlight the importance of including negative controls in all metagenomic analyses, since there was considerable overlap between bacterial content identified in study samples and control samples. For example, Proteobacteria, Firmicutes, Actinobacteria, and Bacteriodes were found in both study samples and plasma-free negative controls. Many of the taxonomic groups we saw in our plasma-free negative control samples have previously been associated with diseases, including ME/CFS, demonstrating how incorrect conclusions may arise if controls are not used and batch effects not accounted for.
Shao, Shiying; Guo, Tiannan; Gross, Vera; Lazarev, Alexander; Koh, Ching Chiek; Gillessen, Silke; Joerger, Markus; Jochum, Wolfram; Aebersold, Ruedi
2016-06-03
The reproducible and efficient extraction of proteins from biopsy samples for quantitative analysis is a critical step in biomarker and translational research. Recently, we described a method consisting of pressure-cycling technology (PCT) and sequential windowed acquisition of all theoretical fragment ions-mass spectrometry (SWATH-MS) for the rapid quantification of thousands of proteins from biopsy-size tissue samples. As an improvement of the method, we have incorporated the PCT-MicroPestle into the PCT-SWATH workflow. The PCT-MicroPestle is a novel, miniaturized, disposable mechanical tissue homogenizer that fits directly into the microTube sample container. We optimized the pressure-cycling conditions for tissue lysis with the PCT-MicroPestle and benchmarked the performance of the system against the conventional PCT-MicroCap method using mouse liver, heart, brain, and human kidney tissues as test samples. The data indicate that the digestion of the PCT-MicroPestle-extracted proteins yielded 20-40% more MS-ready peptide mass from all tissues tested with a comparable reproducibility when compared to the conventional PCT method. Subsequent SWATH-MS analysis identified a higher number of biologically informative proteins from a given sample. In conclusion, we have developed a new device that can be seamlessly integrated into the PCT-SWATH workflow, leading to increased sample throughput and improved reproducibility at both the protein extraction and proteomic analysis levels when applied to the quantitative proteomic analysis of biopsy-level samples.
Tanimoto, Tsuyoshi; Nakanishi, Yoko; Yoshida, Naoko; Tsuboi, Hirohito; Kimura, Kazuko
2012-01-01
Objective To explore the circulation of anti-obesity medicines via the internet and their quality. Design Cross-sectional study. Setting Internet pharmacies and pharmaceutical suppliers accessible from Japan. Participants Anti-obesity medicines were purchased using relevant keywords on Japanese Google search engine. Blogs and advertisement-only sites were excluded. Primary and secondary outcome measures The authenticity of the samples was investigated in collaboration with the manufacturers of the samples and medicine regulatory authorities. Quality of the samples was assessed by pharmacopoeial analyses using high-performance liquid chromatography. Results 82 samples were purchased from 36 internet sites. Approximately half of the sites did not mention a physical address, and 45% of the samples did not contain a package insert. A variety of custom declarations were made for the shipments of the samples: personal health items, supplement, medicines, general merchandise, tea and others. Among 82 samples, 52 samples were analysed to check their pharmacopoeial quality. Authenticity responses were received from only five of 20 manufacturing companies. According to the pharmacopoeial analyses and authenticity investigation, three of the samples were identified as counterfeits and did not contain any active ingredients. Two of these samples were confirmed as counterfeits by the manufacturer of the authentic products. The manufacturer of the other sample did not respond to our request for an authenticity check even after several communication attempts. These counterfeit cases have been reported at the rapid alert system of Western Pacific Region of the WHO. Conclusions Many counterfeit and unapproved anti-obesity medicines may be easily bypassing regulatory checks during shipping and are widely circulated through the internet. Regulatory authorities should take measures to prevent these medicines from entering countries to safeguard their citizens. PMID:22581794
Hammerschmidt, Sebastian B; Wiersberg, Thomas; Heuer, Verena B; Wendt, Jenny; Erzinger, Jörg; Kopf, Achim
2014-01-01
Integrated Ocean Drilling Program Expedition 338 was the second scientific expedition with D/V Chikyu during which riser drilling was conducted as part of the Nankai Trough Seismogenic Zone Experiment. Riser drilling enabled sampling and real-time monitoring of drilling mud gas with an onboard scientific drilling mud gas monitoring system ("SciGas"). A second, independent system was provided by Geoservices, a commercial mud logging service. Both systems allowed the determination of (non-) hydrocarbon gas, while the SciGas system also monitored the methane carbon isotope ratio (δ(13)CCH4). The hydrocarbon gas composition was predominated by methane (> 1%), while ethane and propane were up to two orders of magnitude lower. δ(13)CCH4 values suggested an onset of thermogenic gas not earlier than 1600 meter below seafloor. This study aims on evaluating the onboard data and subsequent geological interpretations by conducting shorebased analyses of drilling mud gas samples. During shipboard monitoring of drilling mud gas the SciGas and Geoservices systems recorded up to 8.64% and 16.4% methane, respectively. Ethane and propane concentrations reached up to 0.03 and 0.013%, respectively, in the SciGas system, but 0.09% and 0.23% in the Geoservices data. Shorebased analyses of discrete samples by gas chromatography showed a gas composition with ~0.01 to 1.04% methane, 2 - 18 ppmv ethane, and 2 - 4 ppmv propane. Quadruple mass spectrometry yielded similar results for methane (0.04 to 4.98%). With δD values between -171‰ and -164‰, the stable hydrogen isotopic composition of methane showed little downhole variability. Although the two independent mud gas monitoring systems and shorebased analysis of discrete gas sample yielded different absolute concentrations they all agree well with respect to downhole variations of hydrocarbon gases. The data point to predominantly biogenic methane sources but suggest some contribution from thermogenic sources at depth, probably due to mixing. In situ thermogenic gas production at depths shallower 2000 mbsf is unlikely based on in situ temperature estimations between 81°C and 85°C and a cumulative time-temperature index of 0.23. In conclusion, the onboard SciGas data acquisition helps to provide a preliminary, qualitative evaluation of the gas composition, the in situ temperature and the possibility of gas migration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flach, G. P.; Whiteside, T. S.
The E-Area Vadose Zone Monitoring System (VZMS) includes lysimeter sampling points at many locations alongside and angling beneath the Engineered Trench #1 (ET1) disposal unit footprint. The sampling points for ET1 were selected for this study because collectively they showed consistently higher tritium (H-3) concentrations than lysimeters associated with other trench units. The VZMS tritium dataset for ET1 from 2001 through 2015 comprises concentrations at or near background levels at approximately half of locations through time, concentrations up to about 600 pCi/mL at a few locations, and concentrations at two locations that have exceeded 1000 pCi/mL. The highest three valuesmore » through 2015 were 6472 pCi/mL in 2014 and 4533 pCi/mL in 2013 at location VL-17, and 3152 pCi/mL in 2007 at location VL-15. As a point of reference, the drinking water standard for tritium and a DOE Order 435.1 performance objective in the saturated zone at the distant 100-meter facility perimeter is 20 pCi/mL. The purpose of this study is to assess whether these elevated concentrations are indicative of a general trend that could challenge 2008 E-Area Performance Assessment (PA) conclusions, or are isolated perturbations that when considered in the context of an entire disposal unit would support PA conclusions.« less
Stark, Lucy; Giersch, Tina; Wünschiers, Röbbe
2014-10-01
Understanding the microbial population in anaerobic digestion is an essential task to increase efficient substrate use and process stability. The metabolic state, represented e.g. by the transcriptome, of a fermenting system can help to find markers for monitoring industrial biogas production to prevent failures or to model the whole process. Advances in next-generation sequencing make transcriptomes accessible for large-scale analyses. In order to analyze the metatranscriptome of a mixed-species sample, isolation of high-quality RNA is the first step. However, different extraction methods may yield different efficiencies in different species. Especially in mixed-species environmental samples, unbiased isolation of transcripts is important for meaningful conclusions. We applied five different RNA-extraction protocols to nine taxonomic diverse bacterial species. Chosen methods are based on various lysis and extraction principles. We found that the extraction efficiency of different methods depends strongly on the target organism. RNA isolation of gram-positive bacteria was characterized by low yield whilst from gram-negative species higher concentrations can be obtained. Transferring our results to mixed-species investigations, such as metatranscriptomics with biofilms or biogas plants, leads to the conclusion that particular microorganisms might be over- or underrepresented depending on the method applied. Special care must be taken when using such metatranscriptomics data for, e.g. process modeling. Copyright © 2013 Elsevier Ltd. All rights reserved.
The importance of replication in wildlife research
Johnson, D.H.
2002-01-01
Wildlife ecology and management studies have been widely criticized for deficiencies in design or analysis. Manipulative experiments--with controls, randomization, and replication in space and time--provide powerful ways of learning about natural systems and establishing causal relationships, but such studies are rare in our field. Observational studies and sample surveys are more common; they also require appropriate design and analysis. More important than the design and analysis of individual studies is metareplication: replication of entire studies. Similar conclusions obtained from studies of the same phenomenon conducted under widely differing conditions will give us greater confidence in the generality of those findings than would any single study, however well designed and executed.
Ultrafast photon counting applied to resonant scanning STED microscopy.
Wu, Xundong; Toro, Ligia; Stefani, Enrico; Wu, Yong
2015-01-01
To take full advantage of fast resonant scanning in super-resolution stimulated emission depletion (STED) microscopy, we have developed an ultrafast photon counting system based on a multigiga sample per second analogue-to-digital conversion chip that delivers an unprecedented 450 MHz pixel clock (2.2 ns pixel dwell time in each scan). The system achieves a large field of view (∼50 × 50 μm) with fast scanning that reduces photobleaching, and advances the time-gated continuous wave STED technology to the usage of resonant scanning with hardware-based time-gating. The assembled system provides superb signal-to-noise ratio and highly linear quantification of light that result in superior image quality. Also, the system design allows great flexibility in processing photon signals to further improve the dynamic range. In conclusion, we have constructed a frontier photon counting image acquisition system with ultrafast readout rate, excellent counting linearity, and with the capacity of realizing resonant-scanning continuous wave STED microscopy with online time-gated detection. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.
Christodoulides, Nicolaos; De La Garza, Richard; Simmons, Glennon W.; McRae, Michael P.; Wong, Jorge; Newton, Thomas F.; Smith, Regina; Mahoney, James J.; Hohenstein, Justin; Gomez, Sobeyda; Floriano, Pierre N.; Talavera, Humberto; Sloan, Daniel J.; Moody, David E.; Andrenyak, David M.; Kosten, Thomas R.; Haque, Ahmed; McDevitt, John T.
2015-01-01
Objective There is currently a gap in on-site drug of abuse monitoring. Current detection methods involve invasive sampling of blood and urine specimens, or collection of oral fluid, followed by qualitative screening tests using immunochromatographic cartridges. While remote laboratories then may provide confirmation and quantitative assessment of a presumptive positive, this instrumentation is expensive and decoupled from the initial sampling making the current drug-screening program inefficient and costly. The authors applied a noninvasive oral fluid sampling approach integrated with the in-development chip-based Programmable Bio-Nano-Chip (p-BNC) platform for the detection of drugs of abuse. Method The p-BNC assay methodology was applied for the detection of tetrahydrocannabinol, morphine, amphetamine, methamphetamine, cocaine, methadone and benzodiazepines, initially using spiked buffered samples and, ultimately, using oral fluid specimen collected from consented volunteers. Results Rapid (~10 minutes), sensitive detection (~ng/ml) and quantitation of 12 drugs of abuse was demonstrated on the p-BNC platform. Furthermore, the system provided visibility to time-course of select drug and metabolite profiles in oral fluids; for the drug cocaine, three regions of slope were observed that, when combined with concentration measurements from this and prior impairment studies, information about cocaine-induced impairment may be revealed. Conclusions This chip-based p-BNC detection modality has significant potential to be used in the future by law enforcement officers for roadside drug testing and to serve a variety of other settings, including outpatient and inpatient drug rehabilitation centers, emergency rooms, prisons, schools, and in the workplace. PMID:26048639
Share2Quit: Web-Based Peer-Driven Referrals for Smoking Cessation
2013-01-01
Background Smoking is the number one preventable cause of death in the United States. Effective Web-assisted tobacco interventions are often underutilized and require new and innovative engagement approaches. Web-based peer-driven chain referrals successfully used outside health care have the potential for increasing the reach of Internet interventions. Objective The objective of our study was to describe the protocol for the development and testing of proactive Web-based chain-referral tools for increasing the access to Decide2Quit.org, a Web-assisted tobacco intervention system. Methods We will build and refine proactive chain-referral tools, including email and Facebook referrals. In addition, we will implement respondent-driven sampling (RDS), a controlled chain-referral sampling technique designed to remove inherent biases in chain referrals and obtain a representative sample. We will begin our chain referrals with an initial recruitment of former and current smokers as seeds (initial participants) who will be trained to refer current smokers from their social network using the developed tools. In turn, these newly referred smokers will also be provided the tools to refer other smokers from their social networks. We will model predictors of referral success using sample weights from the RDS to estimate the success of the system in the targeted population. Results This protocol describes the evaluation of proactive Web-based chain-referral tools, which can be used in tobacco interventions to increase the access to hard-to-reach populations, for promoting smoking cessation. Conclusions Share2Quit represents an innovative advancement by capitalizing on naturally occurring technology trends to recruit smokers to Web-assisted tobacco interventions. PMID:24067329
Children Prefer Diverse Samples for Inductive Reasoning in the Social Domain
ERIC Educational Resources Information Center
Noyes, Alexander; Christie, Stella
2016-01-01
Not all samples of evidence are equally conclusive: Diverse evidence is more representative than narrow evidence. Prior research showed that children did not use sample diversity in evidence selection tasks, indiscriminately choosing diverse or narrow sets (tiger-mouse; tiger-lion) to learn about animals. This failure is not due to a general…
Qualitative Discovery in Medical Databases
NASA Technical Reports Server (NTRS)
Maluf, David A.
2000-01-01
Implication rules have been used in uncertainty reasoning systems to confirm and draw hypotheses or conclusions. However a major bottleneck in developing such systems lies in the elicitation of these rules. This paper empirically examines the performance of evidential inferencing with implication networks generated using a rule induction tool called KAT. KAT utilizes an algorithm for the statistical analysis of empirical case data, and hence reduces the knowledge engineering efforts and biases in subjective implication certainty assignment. The paper describes several experiments in which real-world diagnostic problems were investigated; namely, medical diagnostics. In particular, it attempts to show that: (1) with a limited number of case samples, KAT is capable of inducing implication networks useful for making evidential inferences based on partial observations, and (2) observation driven by a network entropy optimization mechanism is effective in reducing the uncertainty of predicted events.
NASA Technical Reports Server (NTRS)
Stapelfeldt, Karl R.; Brenner, Michael P.; Warfield, Keith R.; Dekens, Frank G.; Belikov, Ruslan; Brugarolas, Paul B.; Bryden, Geoffrey; Cahoy, Kerri L.; Chakrabarti, Supriya; Dubovitsky, Serge;
2014-01-01
"Exo-C" is NASA's first community study of a modest aperture space telescope designed for high contrast observations of exoplanetary systems. The mission will be capable of taking optical spectra of nearby exoplanets in reflected light, discover previously undetected planets, and imaging structure in a large sample of circumstellar disks. It will obtain unique science results on planets down to super-Earth sizes and serve as a technology pathfinder toward an eventual flagship-class mission to find and characterize habitable exoplanets. We present the mission/payload design and highlight steps to reduce mission cost/risk relative to previous mission concepts. At the study conclusion in 2015, NASA will evaluate it for potential development at the end of this decade. Keywords: Exoplanets, high contrast imaging, optical astronomy, space mission concepts
Peppone, Luke J.; Alcaraz, Kassandra; McQueen, Amy; Guido, Joseph J.; Carroll, Jennifer K.; Shacham, Enbal; Morrow, Gary R.
2012-01-01
Objectives. We examined the association between perceived discrimination and smoking status and whether psychological distress mediated this relationship in a large, multiethnic sample. Methods. We used 2004 through 2008 data from the Behavioral Risk Factor Surveillance System Reactions to Race module to conduct multivariate logistic regression analyses and tests of mediation examining associations between perceived discrimination in health care and workplace settings, psychological distress, and current smoking status. Results. Regardless of race/ethnicity, perceived discrimination was associated with increased odds of current smoking. Psychological distress was also a significant mediator of the discrimination–smoking association. Conclusions. Our results indicate that individuals who report discriminatory treatment in multiple domains may be more likely to smoke, in part, because of the psychological distress associated with such treatment. PMID:22420821
NASA Technical Reports Server (NTRS)
Russell, John M.
1994-01-01
In the leak testing of a large engineering system, one may distinguish three stages, namely leakage measurement by an overall enclosure, leak location, and leakage measurement by a local enclosure. Sniffer probes attached to helium mass spectrometer leak detectors are normally designed for leak location, a qualitative inspection technique intended to pinpoint where a leak is but not to quantify its rate of discharge. The main conclusion of the present effort is that local leakage measurement by a leak detector with a sniffer probe is feasible provided one has: (1) quantitative data on the performance of the mass separator cell (a device interior to the unit where the stream of fluid in the sample line branches); and (2) a means of stabilizing the mass transfer boundary layer that is created near a local leak site when a sniffer probe is placed in its immediate vicinity. Theoretical models of the mass separator cell are provided and measurements of the machine-specific parameters in the formulas are presented. A theoretical model of a porous probe end for stabilizing the mass transfer boundary is also presented.
Non-Linear Approach in Kinesiology Should Be Preferred to the Linear--A Case of Basketball.
Trninić, Marko; Jeličić, Mario; Papić, Vladan
2015-07-01
In kinesiology, medicine, biology and psychology, in which research focus is on dynamical self-organized systems, complex connections exist between variables. Non-linear nature of complex systems has been discussed and explained by the example of non-linear anthropometric predictors of performance in basketball. Previous studies interpreted relations between anthropometric features and measures of effectiveness in basketball by (a) using linear correlation models, and by (b) including all basketball athletes in the same sample of participants regardless of their playing position. In this paper the significance and character of linear and non-linear relations between simple anthropometric predictors (AP) and performance criteria consisting of situation-related measures of effectiveness (SE) in basketball were determined and evaluated. The sample of participants consisted of top-level junior basketball players divided in three groups according to their playing time (8 minutes and more per game) and playing position: guards (N = 42), forwards (N = 26) and centers (N = 40). Linear (general model) and non-linear (general model) regression models were calculated simultaneously and separately for each group. The conclusion is viable: non-linear regressions are frequently superior to linear correlations when interpreting actual association logic among research variables.
Helmreich, S; Wechsler, B; Hauser, R; Gygax, L
2016-03-01
In barns with an automatic milking system (AMS), both the milking frequency and the number of nighttime milkings vary between cows. A low milking frequency might indicate problems in gaining access to the milking unit. Also, nighttime lighting in the waiting area of the AMS and in the milking unit increases exposure to light at night and could suppress nocturnal melatonin synthesis. These effects could result in increased stress, suppressed immune response, and poor udder health. A total of 125 cows (14-16/farm) on 8 farms with AMS were selected based on their average milking frequency. Eight to 10 saliva samples per cow were taken over the course of 4 days, and cortisol, IgA and melatonin concentrations were determined. Somatic cell counts (SCC) were determined in milk samples. Milking frequency had no significant relationship with mean cortisol and IgA levels, but a higher milking frequency tended to be associated with lower SCC levels. Nocturnal melatonin levels tended to be negatively associated with the number of nighttime milkings. In conclusion, no indication of increased stress or reduced immune defense was found in relation to milking frequency on farms with an AMS.
NASA Astrophysics Data System (ADS)
Russell, John M.
1994-10-01
In the leak testing of a large engineering system, one may distinguish three stages, namely leakage measurement by an overall enclosure, leak location, and leakage measurement by a local enclosure. Sniffer probes attached to helium mass spectrometer leak detectors are normally designed for leak location, a qualitative inspection technique intended to pinpoint where a leak is but not to quantify its rate of discharge. The main conclusion of the present effort is that local leakage measurement by a leak detector with a sniffer probe is feasible provided one has: (1) quantitative data on the performance of the mass separator cell (a device interior to the unit where the stream of fluid in the sample line branches); and (2) a means of stabilizing the mass transfer boundary layer that is created near a local leak site when a sniffer probe is placed in its immediate vicinity. Theoretical models of the mass separator cell are provided and measurements of the machine-specific parameters in the formulas are presented. A theoretical model of a porous probe end for stabilizing the mass transfer boundary is also presented.
Dispersal of Transgenes through Maize Seed Systems in Mexico
Dyer, George A.; Serratos-Hernández, J. Antonio; Perales, Hugo R.; Gepts, Paul; Piñeyro-Nelson, Alma; Chávez, Angeles; Salinas-Arreortua, Noé; Yúnez-Naude, Antonio; Taylor, J. Edward; Alvarez-Buylla, Elena R.
2009-01-01
Objectives Current models of transgene dispersal focus on gene flow via pollen while neglecting seed, a vital vehicle for gene flow in centers of crop origin and diversity. We analyze the dispersal of maize transgenes via seeds in Mexico, the crop's cradle. Methods We use immunoassays (ELISA) to screen for the activity of recombinant proteins in a nationwide sample of farmer seed stocks. We estimate critical parameters of seed population dynamics using household survey data and combine these estimates with analytical results to examine presumed sources and mechanisms of dispersal. Results Recombinant proteins Cry1Ab/Ac and CP4/EPSPS were found in 3.1% and 1.8% of samples, respectively. They are most abundant in southeast Mexico but also present in the west-central region. Diffusion of seed and grain imported from the United States might explain the frequency and distribution of transgenes in west-central Mexico but not in the southeast. Conclusions Understanding the potential for transgene survival and dispersal should help design methods to regulate the diffusion of germplasm into local seed stocks. Further research is needed on the interactions between formal and informal seed systems and grain markets in centers of crop origin and diversification. PMID:19503610
Hvichia, G E; Parveen, Z; Wagner, C; Janning, M; Quidde, J; Stein, A; Müller, V; Loges, S; Neves, R P L; Stoecklein, N H; Wikman, H; Riethdorf, S; Pantel, K; Gorges, T M
2016-06-15
Circulating tumor cells (CTCs) were introduced as biomarkers more than 10 years ago, but capture of viable CTCs at high purity from peripheral blood of cancer patients is still a major technical challenge. Here, we report a novel microfluidic platform designed for marker independent capture of CTCs. The Parsortix™ cell separation system provides size and deformability-based enrichment with automated staining for cell identification, and subsequent recovery (harvesting) of cells from the device. Using the Parsortix™ system, average cell capture inside the device ranged between 42% and 70%. Subsequent harvest of cells from the device ranged between 54% and 69% of cells captured. Most importantly, 99% of the isolated tumor cells were viable after processing in spiking experiments as well as after harvesting from patient samples and still functional for downstream molecular analysis as demonstrated by mRNA characterization and array-based comparative genomic hybridization. Analyzing clinical blood samples from metastatic (n = 20) and nonmetastatic (n = 6) cancer patients in parallel with CellSearch(®) system, we found that there was no statistically significant difference between the quantitative behavior of the two systems in this set of twenty six paired separations. In conclusion, the epitope independent Parsortix™ system enables the isolation of viable CTCs at a very high purity. Using this system, viable tumor cells are easily accessible and ready for molecular and functional analysis. The system's ability for enumeration and molecular characterization of EpCAM-negative CTCs will help to broaden research into the mechanisms of cancer as well as facilitating the use of CTCs as "liquid biopsies." © 2016 The Authors International Journal of Cancer published by John Wiley & Sons Ltd on behalf of UICC.
NASA Astrophysics Data System (ADS)
Gu, X.; Shao, J.; Cui, Y.
2017-12-01
In this work, hydrogeological and hydrochemical investigations were applied to explain geothermal system factors controlling groundwater mineralization in Arxan geothermal system, Northeastern China. Geothermal water samples were collected from different locations (thermal baths and wells). Radon concentrations of water samples representing different water types and depths were controlled using RAD7. In addition to radon concentration, physical parameters such as temperature (T), pH, electrical conductivity (EC) and TDS were measured in situ, while major ions were analyzed in laboratory. Temperature spatial variability in the study area was described using kriging interpolation method. Hydrochemical analysis and thermal parameters suggest two distinct hydrogeological systems. The first type was dominated by a moderate temperature (25 41°C) with a chemical facies Na-HCO3, which characterizes Jurassic deep water. The second water type was characterized by Ca.Na-HCO3 type with a temperature <25 °C and represents the shallow aquifer. Superficial aquifer displays higher radon concentration (37 to 130 Bq/L), while deep groundwater from Jurassic aquifer shows relatively a low radon concentration (6 to 57.4 Bq/L). Seasonal and geographical variations of radon give insight into the processes controlling radon activities in the Arxan groundwater. Radon concentrations along with spatial distribution of water temperature reveal the existence of vertical communication between shallow aquifer and deep Jurassic aquifer through vertical faults and fractures system, the emanation of radon from thermal water and groundwater is controlled by the geological structure of the area. Furthermore, the knowledge and conclusion demonstrates that combined use of radon and temperature as tracers can give insight into the characteristics of geological structure and geothermal flow system.
Overview of the Spinal Cord Injury – Quality of Life (SCI-QOL) measurement system
Tulsky, David S.; Kisala, Pamela A.; Victorson, David; Tate, Denise G.; Heinemann, Allen W.; Charlifue, Susan; Kirshblum, Steve C.; Fyffe, Denise; Gershon, Richard; Spungen, Ann M.; Bombardier, Charles H.; Dyson-Hudson, Trevor A.; Amtmann, Dagmar; Z. Kalpakjian, Claire; W. Choi, Seung; Jette, Alan M.; Forchheimer, Martin; Cella, David
2015-01-01
Context/Objective The Spinal Cord Injury – Quality of Life (SCI-QOL) measurement system was developed to address the shortage of relevant and psychometrically sound patient reported outcome (PRO) measures available for clinical care and research in spinal cord injury (SCI) rehabilitation. Using a computer adaptive testing (CAT) approach, the SCI-QOL builds on the Patient Reported Outcomes Measurement Information System (PROMIS) and the Quality of Life in Neurological Disorders (Neuro-QOL) initiative. This initial manuscript introduces the background and development of the SCI-QOL measurement system. Greater detail is presented in the additional manuscripts of this special issue. Design Classical and contemporary test development methodologies were employed. Qualitative input was obtained from individuals with SCI and clinicians through interviews, focus groups, and cognitive debriefing. Item pools were field tested in a multi-site sample (n = 877) and calibrated using item response theory methods. Initial reliability and validity testing was performed in a new sample of individuals with traumatic SCI (n = 245). Setting Five Model SCI System centers and one Department of Veterans Affairs Medical Center across the United States. Participants Adults with traumatic SCI. Interventions n/a Outcome Measures n/a Results The SCI-QOL consists of 19 item banks, including the SCI-Functional Index banks, and 3 fixed-length scales measuring physical, emotional, and social aspects of health-related QOL (HRQOL). Conclusion The SCI-QOL measurement system consists of psychometrically sound measures for individuals with SCI. The manuscripts in this special issue provide evidence of the reliability and initial validity of this measurement system. The SCI-QOL also links to other measures designed for a general medical population. PMID:26010962
Penna, Vessoni Thereza Christina; Martins, Silva Alzira Maria; Mazzola, Priscila Gava
2002-01-01
Background A typical purification system that provides purified water which meets ionic and organic chemical standards, must be protected from microbial proliferation to minimize cross-contamination for use in cleaning and preparations in pharmaceutical industries and in health environments. Methodology Samples of water were taken directly from the public distribution water tank at twelve different stages of a typical purification system were analyzed for the identification of isolated bacteria. Two miniature kits were used: (i) identification system (api 20 NE, Bio-Mérieux) for non-enteric and non-fermenting gram-negative rods; and (ii) identification system (BBL crystal, Becton and Dickson) for enteric and non-fermenting gram-negative rods. The efficiency of the chemical sanitizers used in the stages of the system, over the isolated and identified bacteria in the sampling water, was evaluated by the minimum inhibitory concentration (MIC) method. Results The 78 isolated colonies were identified as the following bacteria genera: Pseudomonas, Flavobacterium and Acinetobacter. According to the miniature kits used in the identification, there was a prevalence of isolation of P. aeruginosa 32.05%, P. picketti (Ralstonia picketti) 23.08%, P. vesiculares 12.82%,P. diminuta 11.54%, F. aureum 6.42%, P. fluorescens 5.13%, A. lwoffi 2.56%, P. putida 2.56%, P. alcaligenes 1.28%, P. paucimobilis 1.28%, and F. multivorum 1.28%. Conclusions We found that research was required for the identification of gram-negative non-fermenting bacteria, which were isolated from drinking water and water purification systems, since Pseudomonas genera represents opportunistic pathogens which disperse and adhere easily to surfaces, forming a biofilm which interferes with the cleaning and disinfection procedures in hospital and industrial environments. PMID:12182763
Clinical time series prediction: towards a hierarchical dynamical system framework
Liu, Zitao; Hauskrecht, Milos
2014-01-01
Objective Developing machine learning and data mining algorithms for building temporal models of clinical time series is important for understanding of the patient condition, the dynamics of a disease, effect of various patient management interventions and clinical decision making. In this work, we propose and develop a novel hierarchical framework for modeling clinical time series data of varied length and with irregularly sampled observations. Materials and methods Our hierarchical dynamical system framework for modeling clinical time series combines advantages of the two temporal modeling approaches: the linear dynamical system and the Gaussian process. We model the irregularly sampled clinical time series by using multiple Gaussian process sequences in the lower level of our hierarchical framework and capture the transitions between Gaussian processes by utilizing the linear dynamical system. The experiments are conducted on the complete blood count (CBC) panel data of 1000 post-surgical cardiac patients during their hospitalization. Our framework is evaluated and compared to multiple baseline approaches in terms of the mean absolute prediction error and the absolute percentage error. Results We tested our framework by first learning the time series model from data for the patient in the training set, and then applying the model in order to predict future time series values on the patients in the test set. We show that our model outperforms multiple existing models in terms of its predictive accuracy. Our method achieved a 3.13% average prediction accuracy improvement on ten CBC lab time series when it was compared against the best performing baseline. A 5.25% average accuracy improvement was observed when only short-term predictions were considered. Conclusion A new hierarchical dynamical system framework that lets us model irregularly sampled time series data is a promising new direction for modeling clinical time series and for improving their predictive performance. PMID:25534671
2013-01-01
Background Molecular imaging using magnetic nanoparticles (MNPs)—magnetic particle imaging (MPI)—has attracted interest for the early diagnosis of cancer and cardiovascular disease. However, because a steep local magnetic field distribution is required to obtain a defined image, sophisticated hardware is required. Therefore, it is desirable to realize excellent image quality even with low-performance hardware. In this study, the spatial resolution of MPI was evaluated using an image reconstruction method based on the correlation information of the magnetization signal in a time domain and by applying MNP samples made from biocompatible ferucarbotran that have adjusted particle diameters. Methods The magnetization characteristics and particle diameters of four types of MNP samples made from ferucarbotran were evaluated. A numerical analysis based on our proposed method that calculates the image intensity from correlation information between the magnetization signal generated from MNPs and the system function was attempted, and the obtained image quality was compared with that using the prototype in terms of image resolution and image artifacts. Results MNP samples obtained by adjusting ferucarbotran showed superior properties to conventional ferucarbotran samples, and numerical analysis showed that the same image quality could be obtained using a gradient magnetic field generator with 0.6 times the performance. However, because image blurring was included theoretically by the proposed method, an algorithm will be required to improve performance. Conclusions MNP samples obtained by adjusting ferucarbotran showed magnetizing properties superior to conventional ferucarbotran samples, and by using such samples, comparable image quality (spatial resolution) could be obtained with a lower gradient magnetic field intensity. PMID:23734917
Tsujimura-Ito, Takako; Inoue, Yusuke; Muto, Kaori; Yoshida, Ken-Ichi
2017-04-01
Background Leftover samples obtained during autopsies are extremely important basic materials for forensic research. However, there are no established practices for research-related use of obtained samples. Objective This study discusses good practice for the secondary use of samples collected during medicolegal autopsies. Methods A questionnaire was posted to all 76 departments of forensic medicine performing medicolegal autopsies in Japan, and 48 responses were received (response rate: 63.2%). As a secondary analysis, we surveyed information provided on department websites. Results Ethical reviews conducted when samples were to be used for research varied greatly among departments, with 21 (43.8%) departments reporting 'fundamentally, all cases are subject to review', eight (16.7%) reporting 'only some are subject to review' and 17 (39.6%) reporting 'none are subject to review'. Information made available on websites indicated that 11 departments had a statement of some type to bereaved families about the potential research use of human samples obtained during autopsies. Nine of these included a notice stating that bereaved families may revoke their consent for use. Several departments used an opt-out system. Conclusion There is no common practice in the field of legal medicine on the ethical use for medical research of leftover samples from medicolegal autopsies. The trust of not only bereaved families but also society in general is required for the scientific validity and social benefits of medical studies using leftover samples from medicolegal autopsies through the use of opt-out consenting and offline and online dissemination and public-relations activities.
ORDINOLA-ZAPATA, Ronald; BRAMANTE, Clovis Monteiro; DUARTE, Marco Antonio Húngaro; CAVENAGO, Bruno Cavalini; JARAMILLO, David; VERSIANI, Marco Aurélio
2014-01-01
Objective: To evaluate the shaping ability of Reciproc and Twisted-File Adaptive systems in rapid prototyping replicas. Material and Methods: Two mandibular molars showing S-shaped and 62-degree curvatures in the mesial root were scanned by using a microcomputed tomography (μCT) system. The data were exported in the stereolitograhic format and 20 samples of each molar were printed at 16 µm resolution. The mesial canals of 10 replicas of each specimen were prepared with each system. Transportation was measured by overlapping radiographs taken before and after preparation and resin thickness after instrumentation was measured by μCT. Results: Both systems maintained the original shape of the apical third in both anatomies (P>0.05). Overall, considering the resin thickness in the 62-degree replicas, no statistical difference was found between the systems (P>0.05). In the S-shaped curvature replica, Reciproc significantly decreased the thickness of the resin walls in comparison with TF Adaptive. Conclusions: The evaluated systems were able to maintain the original shape at the apical third of severely curved mesial canals of molar replicas. PMID:24918662
Hefner, Jennifer; Robbins, Julie; Huerta, Timothy R.
2013-01-01
Background. Ambulatory care practices have increasing interest in leveraging the capabilities of electronic health record (EHR) systems, but little information is available documenting how organizations have successfully implemented these systems. Objective. To characterize elements of successful electronic health record (EHR) system implementation and to synthesize the key informants' perspectives about successful implementation practices. Methods. Key informant interviews and focus groups were conducted with a purposive sample of individuals from US healthcare organizations identified for their success with ambulatory EHR implementation. Rigorous qualitative data analyses used both deductive and inductive methods. Results. Participants identified personal and system-related barriers, at both the individual and organization levels, including poor computer skills, productivity losses, resistance to change, and EHR system failure. Implementation success was reportedly facilitated by careful planning and consistent communication throughout distinct stages of the implementation process. A significant element of successful implementation was an emphasis on optimization, both during “go-live” and, subsequently, when users had more experience with the system. Conclusion. Successful EHR implementation requires both detailed planning and clear mechanisms to deal with unforeseen or unintended consequences. Focusing on user buy-in early and including plans for optimization can facilitate greater success. PMID:24228257
A high-throughput core sampling device for the evaluation of maize stalk composition
2012-01-01
Background A major challenge in the identification and development of superior feedstocks for the production of second generation biofuels is the rapid assessment of biomass composition in a large number of samples. Currently, highly accurate and precise robotic analysis systems are available for the evaluation of biomass composition, on a large number of samples, with a variety of pretreatments. However, the lack of an inexpensive and high-throughput process for large scale sampling of biomass resources is still an important limiting factor. Our goal was to develop a simple mechanical maize stalk core sampling device that can be utilized to collect uniform samples of a dimension compatible with robotic processing and analysis, while allowing the collection of hundreds to thousands of samples per day. Results We have developed a core sampling device (CSD) to collect maize stalk samples compatible with robotic processing and analysis. The CSD facilitates the collection of thousands of uniform tissue cores consistent with high-throughput analysis required for breeding, genetics, and production studies. With a single CSD operated by one person with minimal training, more than 1,000 biomass samples were obtained in an eight-hour period. One of the main advantages of using cores is the high level of homogeneity of the samples obtained and the minimal opportunity for sample contamination. In addition, the samples obtained with the CSD can be placed directly into a bath of ice, dry ice, or liquid nitrogen maintaining the composition of the biomass sample for relatively long periods of time. Conclusions The CSD has been demonstrated to successfully produce homogeneous stalk core samples in a repeatable manner with a throughput substantially superior to the currently available sampling methods. Given the variety of maize developmental stages and the diversity of stalk diameter evaluated, it is expected that the CSD will have utility for other bioenergy crops as well. PMID:22548834
Measurements of CaII absorption, metals and dust in a sample of z ~= 1 DLAs and subDLAs
NASA Astrophysics Data System (ADS)
Nestor, Daniel B.; Pettini, Max; Hewett, Paul C.; Rao, Sandhya; Wild, Vivienne
2008-11-01
We present observations of CaII, ZnII and CrII absorption lines in 16 damped Lyman alpha (DLA) systems and six subDLAs at redshifts 0.6 < zabs < 1.3, obtained for the dual purposes of (i) clarifying the relationship between DLAs and absorption systems selected from their strong CaII lines, and (ii) increasing the still limited sample of Zn and Cr abundance determinations in this redshift range. We find only partial overlap between current samples of intermediate redshift DLAs (which are drawn from magnitude-limited surveys) and strong CaII absorbers: approximately 25 per cent of known DLAs at these redshifts have an associated CaII λ3935 line with a rest-frame equivalent width greater than 0.35 Å, the threshold of the Sloan Digital Sky Survey sample assembled by Wild and her collaborators. The lack of the strongest CaII systems (with equivalent widths greater than 0.5 Å) is consistent with these authors' conclusion that such absorbers are often missed in current DLA surveys because they redden and dim the light of the background quasi-stellar objects. We rule out the suggestion that strong CaII absorption is associated exclusively with the highest column density DLAs. Furthermore, we find no correlation between the strength of the CaII lines and either the metallicity or degree of depletion of refractory elements, although the strongest CaII absorber in our sample is also the most metal-rich DLA yet discovered, with [Zn/H] ~= solar. We conclude that a complex mix of parameters must determine the strengths of the CaII lines, including the density of particles and ultraviolet photons in the interstellar media of the galaxies hosting the DLAs. We find tentative evidence (given the small size of our sample) that strong CaII systems may preferentially sample regions of high gas density, perhaps akin to the DLAs exhibiting molecular hydrogen absorption at redshifts z > 2. If this connection is confirmed, strong CaII absorbers would trace possibly metal rich, H2 bearing columns of cool, dense gas at distances up to tens of kpc from normal galaxies. Based on the observations made with the William Herschel Telescope operated on the island of La Palma by the Isaac Newton Group in the Spanish Observatorio del Roque de los Muchachos of the Instituto de Astrofísica de Canarias. E-mail: dbn@ast.cam.ac.uk
2012-01-01
Background No previous studies have addressed the integrated relationships among system quality, service quality, job satisfaction, and system performance; this study attempts to bridge such a gap with evidence-based practice study. Methods The convenience sampling method was applied to the information system users of three hospitals in southern Taiwan. A total of 500 copies of questionnaires were distributed, and 283 returned copies were valid, suggesting a valid response rate of 56.6%. SPSS 17.0 and AMOS 17.0 (structural equation modeling) statistical software packages were used for data analysis and processing. Results The findings are as follows: System quality has a positive influence on service quality (γ11= 0.55), job satisfaction (γ21= 0.32), and system performance (γ31= 0.47). Service quality (β31= 0.38) and job satisfaction (β32= 0.46) will positively influence system performance. Conclusions It is thus recommended that the information office of hospitals and developers take enhancement of service quality and user satisfaction into consideration in addition to placing b on system quality and information quality when designing, developing, or purchasing an information system, in order to improve benefits and gain more achievements generated by hospital information systems. PMID:23171394
Pediatric post-marketing safety systems in North America: assessment of the current status.
McMahon, Ann W; Wharton, Gerold T; Bonnel, Renan; DeCelle, Mary; Swank, Kimberley; Testoni, Daniela; Cope, Judith U; Smith, Phillip Brian; Wu, Eileen; Murphy, Mary Dianne
2015-08-01
It is critical to have pediatric post-marketing safety systems that contain enough clinical and epidemiological detail to draw regulatory, public health, and clinical conclusions. The pediatric safety surveillance workshop (PSSW), coordinated by the Food and Drug Administration (FDA), identified these pediatric systems as of 2010. This manuscript aims to update the information from the PSSW and look critically at the systems currently in use. We reviewed North American pediatric post-marketing safety systems such as databases, networks, and research consortiums found in peer-reviewed journals and other online sources. We detail clinical examples from three systems that FDA used to assess pediatric medical product safety. Of the 59 systems reviewed for pediatric content, only nine were pediatric-focused and met the inclusion criteria. Brief descriptions are provided for these nine. The strengths and weaknesses of three systems (two of the nine pediatric-focused and one including both children and adults) are illustrated with clinical examples. Systems reviewed in this manuscript have strengths such as clinical detail, a large enough sample size to capture rare adverse events, and/or a patient denominator internal to the database. Few systems include all of these attributes. Pediatric drug safety would be better informed by utilizing multiple systems to take advantage of their individual characteristics. Copyright © 2015 John Wiley & Sons, Ltd.
Methods and metrics challenges of delivery-system research
2012-01-01
Background Many delivery-system interventions are fundamentally about change in social systems (both planned and unplanned). This systems perspective raises a number of methodological challenges for studying the effects of delivery-system change--particularly for answering questions related to whether the change will work under different conditions and how the change is integrated (or not) into the operating context of the delivery system. Methods The purpose of this paper is to describe the methodological and measurement challenges posed by five key issues in delivery-system research: (1) modeling intervention context; (2) measuring readiness for change; (3) assessing intervention fidelity and sustainability; (4) assessing complex, multicomponent interventions; and (5) incorporating time in delivery-system models to discuss recommendations for addressing these issues. For each issue, we provide recommendations for how research may be designed and implemented to overcome these challenges. Results and conclusions We suggest that a more refined understanding of the mechanisms underlying delivery-system interventions (treatment theory) and the ways in which outcomes for different classes of individuals change over time are fundamental starting points for capturing the heterogeneity in samples of individuals exposed to delivery-system interventions. To support the research recommendations outlined in this paper and to advance understanding of the "why" and "how" questions of delivery-system change and their effects, funding agencies should consider supporting studies with larger organizational sample sizes; longer duration; and nontraditional, mixed-methods designs. A version of this paper was prepared under contract with the Agency for Healthcare Research and Quality (AHRQ), US Department of Health and Human Services for presentation and discussion at a meeting on "The Challenge and Promise of Delivery System Research," held in Sterling, VA, on February 16-17, 2011. The opinions in the paper are those of the author and do not represent the views or recommendations of AHRQ or the US Department of Health and Human Services.1 PMID:22409885
Measuring pedestrian volumes and conflicts. Volume 1, Pedestrian volume sampling
DOT National Transportation Integrated Search
1987-12-01
This final report presents the findings, conclusions, and recommendations of the study conducted to develop a model to predict pedestrian volumes using small sampling schemes. This research produced four pedestrian volume prediction models (i.e., 1-,...
Arnabat, J; España-Tost, T
2012-01-01
Objective: To analyse microleakage in Class V cavity preparation with Er;Cr:YSGG at different parameters using a self-etching adhesive system. Background: Several studies reported microleakage around composite restorations when cavity preparation is done or treated by Er;Cr:YSGG laser. We want to compare different energy densities in order to obtain the best parameters, when using a self-etching adhesive system. Methods: A class V preparations was performed in 120 samples of human teeth were divided in 3 groups: (1) Preparation using the burr. (2) Er;Cr:YSGG laser preparation with high energy 4W, 30 Hz, 50% Water 50% Air and (3) Er;Cr:YSGG laser preparation lower energy 1.5 W, 30 Hz, 30% Water 30% Air. All the samples were restored with self-etching adhesive system and hybrid composite. Thermocycling (5000 cycles) and immersed in 0.5% fuchsin. The restorations were sectioned and evaluated the microleakage with a stereomicroscope. Results: Lower energy laser used for preparation showed significant differences in enamel and dentin. To group 3, the microleakage in the enamel was less, whilst the group 1, treated with the turbine, showed less microleakage at dentin level. Group 2 showed the highest microleakage at dentin/cement level. Conclusion: Burr preparation gives the lowest microleakage at cement/dentin level, whilst Er;Cr:YSGG laser at lower power has the low energy obtains lowest microleakage at enamel. On the contrary high-energy settings produce inferior results in terms of microleakage. PMID:24511195
HEARTBEAT STARS: SPECTROSCOPIC ORBITAL SOLUTIONS FOR SIX ECCENTRIC BINARY SYSTEMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smullen, Rachel A.; Kobulnicky, Henry A., E-mail: rsmullen@email.arizona.edu
2015-08-01
We present multi-epoch spectroscopy of “heartbeat stars,” eccentric binaries with dynamic tidal distortions and tidally induced pulsations originally discovered with the Kepler satellite. Optical spectra of six known heartbeat stars using the Wyoming Infrared Observatory 2.3 m telescope allow measurement of stellar effective temperatures and radial velocities from which we determine orbital parameters including the periods, eccentricities, approximate mass ratios, and component masses. These spectroscopic solutions confirm that the stars are members of eccentric binary systems with eccentricities e > 0.34 and periods P = 7–20 days, strengthening conclusions from prior works that utilized purely photometric methods. Heartbeat stars inmore » this sample have A- or F-type primary components. Constraints on orbital inclinations indicate that four of the six systems have minimum mass ratios q = 0.3–0.5, implying that most secondaries are probable M dwarfs or earlier. One system is an eclipsing, double-lined spectroscopic binary with roughly equal-mass mid-A components (q = 0.95), while another shows double-lined behavior only near periastron, indicating that the F0V primary has a G1V secondary (q = 0.65). This work constitutes the first measurements of the masses of secondaries in a statistical sample of heartbeat stars. The good agreement between our spectroscopic orbital elements and those derived using a photometric model support the idea that photometric data are sufficient to derive reliable orbital parameters for heartbeat stars.« less
MolabIS - An integrated information system for storing and managing molecular genetics data
2011-01-01
Background Long-term sample storage, tracing of data flow and data export for subsequent analyses are of great importance in genetics studies. Therefore, molecular labs do need a proper information system to handle an increasing amount of data from different projects. Results We have developed a molecular labs information management system (MolabIS). It was implemented as a web-based system allowing the users to capture original data at each step of their workflow. MolabIS provides essential functionality for managing information on individuals, tracking samples and storage locations, capturing raw files, importing final data from external files, searching results, accessing and modifying data. Further important features are options to generate ready-to-print reports and convert sequence and microsatellite data into various data formats, which can be used as input files in subsequent analyses. Moreover, MolabIS also provides a tool for data migration. Conclusions MolabIS is designed for small-to-medium sized labs conducting Sanger sequencing and microsatellite genotyping to store and efficiently handle a relative large amount of data. MolabIS not only helps to avoid time consuming tasks but also ensures the availability of data for further analyses. The software is packaged as a virtual appliance which can run on different platforms (e.g. Linux, Windows). MolabIS can be distributed to a wide range of molecular genetics labs since it was developed according to a general data model. Released under GPL, MolabIS is freely available at http://www.molabis.org. PMID:22040322
Proinflammatory cytokines, sickness behavior, and Alzheimer disease
Cunningham, C.; Zotova, E.; Culliford, D.; Perry, V.H.
2011-01-01
Background: In Alzheimer disease (AD), systemic inflammation is known to give rise to a delirium. However, systemic inflammation also gives rise to other centrally mediated symptoms in the absence of a delirium, a concept known as sickness behavior. Systemic inflammation is characterized by the systemic production of the proinflammatory cytokines tumor necrosis factor–α (TNFα) and interleukin-6 (IL-6) that mediate immune to brain communication and the development of sickness behavior. Objective: To determine if raised serum TNFα or IL-6 are associated with the presence of sickness behavior symptoms, independent of the development of delirium, in a prospective cohort study of subjects with AD. Methods: A total of 300 subjects with mild to severe AD were cognitively assessed at baseline and a blood sample taken for inflammatory markers. Cognitive assessments, including assessments to detect the development of a delirium, and blood samples were repeated at 2, 4, and 6 months. The development of neuropsychiatric symptoms in the subject with AD over the 6-month follow-up period was assessed independently by carer interview at 2, 4, and 6 months. Results: Raised serum TNFα and IL-6, but not CRP, were associated with an approximately 2-fold increased frequency of neuropsychiatric symptoms characteristic of sickness behavior. These relationships are independent of the development of delirium. Conclusions: Increased serum proinflammatory cytokines are associated with the presence of symptoms characteristic of sickness behavior, which are common neuropsychiatric features found in AD. This association was independent of the presence of delirium. PMID:21753171
Health systems performance in sub-Saharan Africa: governance, outcome and equity
2011-01-01
Background The literature on health systems focuses largely on the performance of healthcare systems operationalised around indicators such as hospital beds, maternity care and immunisation coverage. A broader definition of health systems however, needs to include the wider determinants of health including, possibly, governance and its relationship to health and health equity. The aim of this study was to examine the relationship between health systems outcomes and equity, and governance as a part of a process to extend the range of indicators used to assess health systems performance. Methods Using cross sectional data from 46 countries in the African region of the World Health Organization, an ecological analysis was conducted to examine the relationship between governance and health systems performance. The data were analysed using multiple linear regression and a standard progressive modelling procedure. The under-five mortality rate (U5MR) was used as the health outcome measure and the ratio of U5MR in the wealthiest and poorest quintiles was used as the measure of health equity. Governance was measured using two contextually relevant indices developed by the Mo Ibrahim Foundation. Results Governance was strongly associated with U5MR and moderately associated with the U5MR quintile ratio. After controlling for possible confounding by healthcare, finance, education, and water and sanitation, governance remained significantly associated with U5MR. Governance was not, however, significantly associated with equity in U5MR outcomes. Conclusion This study suggests that the quality of governance may be an important structural determinant of health systems performance, and could be an indicator to be monitored. The association suggests there might be a causal relationship. However, the cross-sectional design, the level of missing data, and the small sample size, forces tentative conclusions. Further research will be needed to assess the causal relationship, and its generalizability beyond U5MR as a health outcome measure, as well as the geographical generalizability of the results. PMID:21496303
Selection of species and sampling areas: The importance of inference
Paul Stephen Corn
2009-01-01
Inductive inference, the process of drawing general conclusions from specific observations, is fundamental to the scientific method. Platt (1964) termed conclusions obtained through rigorous application of the scientific method as "strong inference" and noted the following basic steps: generating alternative hypotheses; devising experiments, the...
The Hawaiian Freshwater Algal Database (HfwADB): a laboratory LIMS and online biodiversity resource
2012-01-01
Background Biodiversity databases serve the important role of highlighting species-level diversity from defined geographical regions. Databases that are specially designed to accommodate the types of data gathered during regional surveys are valuable in allowing full data access and display to researchers not directly involved with the project, while serving as a Laboratory Information Management System (LIMS). The Hawaiian Freshwater Algal Database, or HfwADB, was modified from the Hawaiian Algal Database to showcase non-marine algal specimens collected from the Hawaiian Archipelago by accommodating the additional level of organization required for samples including multiple species. Description The Hawaiian Freshwater Algal Database is a comprehensive and searchable database containing photographs and micrographs of samples and collection sites, geo-referenced collecting information, taxonomic data and standardized DNA sequence data. All data for individual samples are linked through unique 10-digit accession numbers (“Isolate Accession”), the first five of which correspond to the collection site (“Environmental Accession”). Users can search online for sample information by accession number, various levels of taxonomy, habitat or collection site. HfwADB is hosted at the University of Hawaii, and was made publicly accessible in October 2011. At the present time the database houses data for over 2,825 samples of non-marine algae from 1,786 collection sites from the Hawaiian Archipelago. These samples include cyanobacteria, red and green algae and diatoms, as well as lesser representation from some other algal lineages. Conclusions HfwADB is a digital repository that acts as a Laboratory Information Management System for Hawaiian non-marine algal data. Users can interact with the repository through the web to view relevant habitat data (including geo-referenced collection locations) and download images of collection sites, specimen photographs and micrographs, and DNA sequences. It is publicly available at http://algae.manoa.hawaii.edu/hfwadb/. PMID:23095476
The GDNF System Is Altered in Diverticular Disease – Implications for Pathogenesis
Böttner, Martina; Barrenschee, Martina; Hellwig, Ines; Harde, Jonas; Egberts, Jan-Hendrik; Becker, Thomas; Zorenkov, Dimitri; Schäfer, Karl-Herbert; Wedel, Thilo
2013-01-01
Background & Aims Absence of glial cell line-derived neurotrophic factor (GDNF) leads to intestinal aganglionosis. We recently demonstrated that patients with diverticular disease (DD) exhibit hypoganglionosis suggesting neurotrophic factor deprivation. Thus, we screened mRNA expression pattern of the GDNF system in DD and examined the effects of GDNF on cultured enteric neurons. Methods Colonic specimens obtained from patients with DD (n = 21) and controls (n = 20) were assessed for mRNA expression levels of the GDNF system (GDNF, GDNF receptors GFRα1 and RET). To identify the tissue source of GDNF and its receptors, laser-microdissected (LMD) samples of human myenteric ganglia and intestinal muscle layers were analyzed separately by qPCR. Furthermore, the effects of GDNF treatment on cultured enteric neurons (receptor expression, neuronal differentiation and plasticity) were monitored. Results mRNA expression of GDNF and its receptors was significantly down-regulated in the muscularis propria of patients with DD. LMD samples revealed high expression of GDNF in circular and longitudinal muscle layers, whereas GDNF receptors were also expressed in myenteric ganglia. GDNF treatment of cultured enteric neurons increased mRNA expression of its receptors and promoted neuronal differentiation and plasticity revealed by synaptophysin mRNA and protein expression. Conclusions Our results suggest that the GDNF system is compromised in DD. In vitro studies demonstrate that GDNF enhances expression of its receptors and promotes enteric neuronal differentiation and plasticity. Since patients with DD exhibit hypoganglionosis, we propose that the observed enteric neuronal loss in DD may be due to lacking neurotrophic support mediated by the GDNF system. PMID:23805210
Subchondral bone histology and grading in osteoarthritis
Aho, Olli-Matti; Finnilä, Mikko; Thevenot, Jerome; Saarakkala, Simo; Lehenkari, Petri
2017-01-01
Objective Osteoarthritis (OA) has often regarded as a disease of articular cartilage only. New evidence has shifted the paradigm towards a system biology approach, where also the surrounding tissue, especially bone is studied more vigorously. However, the histological features of subchondral bone are only poorly characterized in current histological grading scales of OA. The aim of this study is to specifically characterize histological changes occurring in subchondral bone at different stages of OA and propose a simple grading system for them. Design 20 patients undergoing total knee replacement surgery were randomly selected for the study and series of osteochondral samples were harvested from the tibial plateaus for histological analysis. Cartilage degeneration was assessed using the standardized OARSI grading system, while a novel four-stage grading system was developed to illustrate the changes in subchondral bone. Subchondral bone histology was further quantitatively analyzed by measuring the thickness of uncalcified and calcified cartilage as well as subchondral bone plate. Furthermore, internal structure of calcified cartilage-bone interface was characterized utilizing local binary patterns (LBP) based method. Results The histological appearance of subchondral bone changed drastically in correlation with the OARSI grading of cartilage degeneration. As the cartilage layer thickness decreases the subchondral plate thickness and disorientation, as measured with LBP, increases. Calcified cartilage thickness was highest in samples with moderate OA. Conclusion The proposed grading system for subchondral bone has significant relationship with the corresponding OARSI grading for cartilage. Our results suggest that subchondral bone remodeling is a fundamental factor already in early stages of cartilage degeneration. PMID:28319157
2010-01-01
Background The routes by which humans acquire influenza H5N1 infections have not been fully elucidated. Based on the known biology of influenza viruses, four modes of transmission are most likely in humans: aerosol transmission, ingestion of undercooked contaminated infected poultry, transmission by large droplets and self-inoculation of the nasal mucosa by contaminated hands. In preparation of a study to resolve whether H5N1 viruses are transmissible by aerosol in an animal model that is a surrogate for humans, an inhalation exposure system for studies of aerosolized H5N1 viruses in ferrets was designed, assembled, and validated. Particular attention was paid towards system safety, efficacy of dissemination, the viability of aerosolized virus, and sampling methodology. Results An aerosol generation and delivery system, referred to as a Nose-Only Bioaerosol Exposure System (NBIES), was assembled and function tested. The NBIES passed all safety tests, met expected engineering parameters, required relatively small quantities of material to obtain the desired aerosol concentrations of influenza virus, and delivered doses with high-efficacy. Ferrets withstood a mock exposure trial without signs of stress. Conclusions The NBIES delivers doses of aerosolized influenza viruses with high efficacy, and uses less starting material than other similar designs. Influenza H5N1 and H3N2 viruses remain stable under the conditions used for aerosol generation and sample collection. The NBIES is qualified for studies of aerosolized H5N1 virus. PMID:20573226
Geng, Chun-Song; Wan, Zhen; Feng, Ya-Hong; Fan, Yi-Sun
2012-06-25
To investigate the mechanisms underlying the cholinergic agonist carbachol-induced cardiovascular responses, changes of renin-angiotensin system were examined in fetal hormonal systems. In the ovine fetal model under stressless condition, the cardiovascular function was recorded. Blood samples were collected before (during baseline period) and after the intravenous administration of carbachol. Simultaneously, the levels of angiotensin I (Ang I), angiotensin II (Ang II) and vasopressin in the fetal plasma were detected by immunoradiological method. Also, blood gas, plasma osmolality and electrolyte concentrations were analyzed in blood samples. Results showed that in chronically prepared ovine fetus, intravenous infusion of carbachol led to a significant decrease of heart rate (P < 0.05), and a transient decrease followed by an increase of blood pressure (P < 0.05) within 30 min. After the intravenous infusion of carbachol, blood concentrations of Ang I and Ang II in near-term ovine fetus were both significantly increased (P < 0.05); however, blood concentration of vasopressin, values of blood gas, electrolytes and plasma osmolality in near-term ovine fetus were not significantly changed (P > 0.05). Blood levels of Ang I and Ang II in the atropine (M receptor antagonist) + carbachol intravenous administration group was lower than those in the carbachol group without atropine administration (P < 0.05). In conclusion, this study indicates that the near-term changes of cardiovascular system induced by intravenous administration of carbachol in ovine fetus, such as blood pressure and heart rate, are associated with the changes of hormones of circulatory renin-angiotensin system.
Quality testing of an innovative cascade separation system for multiple cell separation
NASA Astrophysics Data System (ADS)
Pierzchalski, Arkadiusz; Moszczynska, Aleksandra; Albrecht, Bernd; Heinrich, Jan-Michael; Tarnok, Attila
2012-03-01
Isolation of different cell types from mixed samples in one separation step by FACS is feasible but expensive and slow. It is cheaper and faster but still challenging by magnetic separation. An innovative bead-based cascade-system (pluriSelect GmbH, Leipzig, Germany) relies on simultaneous physical separation of different cell types. It is based on antibody-mediated binding of cells to beads of different size and isolation with sieves of different mesh-size. We validated pluriSelect system for single parameter (CD3) and simultaneous separation of CD3 and CD15 cells from EDTA blood-samples. Results were compared with those obtained by MACS (Miltenyi-Biotech) magnetic separation (CD3 separation). pluriSelect separation was done in whole blood, MACS on Ficoll gradient isolated leukocytes, according to the manufacturer's protocols. Isolated and residual cells were immunophenotyped (7-color 8-antibody panel (CD3; CD16/56; CD4; CD8; CD14; CD19; CD45; HLADR) on a CyFlowML flow cytometer (Partec GmbH). Cell count (Coulter), purity, yield and viability (7-AAD exclusion) were determined. There were no significant differences between both systems regarding purity (92-98%), yield (50-60%) and viability (92-98%) of isolated cells. PluriSelect separation was slightly faster than MACS (1.15 h versus 1.5h). Moreover, no preenrichment steps were necessary. In conclusion, pluriSelect is a fast, simple and gentle system for efficient simultaneous separation of two cell subpopulation directly from whole blood and can provide a simple alternative to FACS. The isolated cells can be used for further research applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Peter R., E-mail: pmarti46@uwo.ca; Cool, Derek W.; Romagnoli, Cesare
2014-07-15
Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiologymore » resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was consistently greater when using spherical tumor shapes as opposed to no shape assumption. However, an assumption of spherical tumor shape for RMSE = 3.5 mm led to a mean overestimation of tumor sampling probabilities of 3%, implying that assuming spherical tumor shape may be reasonable for many prostate tumors. The authors also determined that a biopsy system would need to have a RMS needle delivery error of no more than 1.6 mm in order to sample 95% of tumors with one core. The authors’ experiments also indicated that the effect of axial-direction error on the measured tumor burden was mitigated by the 18 mm core length at 3.5 mm RMSE. Conclusions: For biopsy systems with RMSE ≥ 3.5 mm, more than one biopsy core must be taken from the majority of tumors to achieveP ≥ 95%. These observations support the authors’ perspective that some tumors of clinically significant sizes may require more than one biopsy attempt in order to be sampled during the first biopsy session. This motivates the authors’ ongoing development of an approach to optimize biopsy plans with the aim of achieving a desired probability of obtaining a sample from each tumor, while minimizing the number of biopsies. Optimized planning of within-tumor targets for MRI-3D TRUS fusion biopsy could support earlier diagnosis of prostate cancer while it remains localized to the gland and curable.« less
The Hawaiian Algal Database: a laboratory LIMS and online resource for biodiversity data
Wang, Norman; Sherwood, Alison R; Kurihara, Akira; Conklin, Kimberly Y; Sauvage, Thomas; Presting, Gernot G
2009-01-01
Background Organization and presentation of biodiversity data is greatly facilitated by databases that are specially designed to allow easy data entry and organized data display. Such databases also have the capacity to serve as Laboratory Information Management Systems (LIMS). The Hawaiian Algal Database was designed to showcase specimens collected from the Hawaiian Archipelago, enabling users around the world to compare their specimens with our photographs and DNA sequence data, and to provide lab personnel with an organizational tool for storing various biodiversity data types. Description We describe the Hawaiian Algal Database, a comprehensive and searchable database containing photographs and micrographs, geo-referenced collecting information, taxonomic checklists and standardized DNA sequence data. All data for individual samples are linked through unique accession numbers. Users can search online for sample information by accession number, numerous levels of taxonomy, or collection site. At the present time the database contains data representing over 2,000 samples of marine, freshwater and terrestrial algae from the Hawaiian Archipelago. These samples are primarily red algae, although other taxa are being added. Conclusion The Hawaiian Algal Database is a digital repository for Hawaiian algal samples and acts as a LIMS for the laboratory. Users can make use of the online search tool to view and download specimen photographs and micrographs, DNA sequences and relevant habitat data, including georeferenced collecting locations. It is publicly available at . PMID:19728892
[Study on infrared spectrum change of Ganoderma lucidum and its extracts].
Chen, Zao-Xin; Xu, Yong-Qun; Chen, Xiao-Kang; Huang, Dong-Lan; Lu, Wen-Guan
2013-05-01
From the determination of the infrared spectra of four substances (original ganoderma lucidum and ganoderma lucidum water extract, 95% ethanol extract and petroleum ether extract), it was found that the infrared spectrum can carry systematic chemical information and basically reflects the distribution of each component of the analyte. Ganoderma lucidum and its extracts can be distinguished according to the absorption peak area ratio of 3 416-3 279, 1 541 and 723 cm(-1) to 2 935-2 852 cm(-1). A method of calculating the information entropy of the sample set with Euclidean distance was proposed, the relationship between the information entropy and the amount of chemical information carried by the sample set was discussed, and the authors come to a conclusion that sample set of original ganoderma lucidum carry the most abundant chemical information. The infrared spectrum set of original ganoderma lucidum has better clustering effect on ganoderma atrum, Cyan ganoderma, ganoderma multiplicatum and ganoderma lucidum when making hierarchical cluster analysis of 4 sample set. The results show that infrared spectrum carries the chemical information of the material structure and closely relates to the chemical composition of the system. The higher the value of information entropy, the much richer the chemical information and the more the benefit for pattern recognition. This study has a guidance function to the construction of the sample set in pattern recognition.
SSAGES: Software Suite for Advanced General Ensemble Simulations.
Sidky, Hythem; Colón, Yamil J; Helfferich, Julian; Sikora, Benjamin J; Bezik, Cody; Chu, Weiwei; Giberti, Federico; Guo, Ashley Z; Jiang, Xikai; Lequieu, Joshua; Li, Jiyuan; Moller, Joshua; Quevillon, Michael J; Rahimi, Mohammad; Ramezani-Dakhel, Hadi; Rathee, Vikramjit S; Reid, Daniel R; Sevgen, Emre; Thapar, Vikram; Webb, Michael A; Whitmer, Jonathan K; de Pablo, Juan J
2018-01-28
Molecular simulation has emerged as an essential tool for modern-day research, but obtaining proper results and making reliable conclusions from simulations requires adequate sampling of the system under consideration. To this end, a variety of methods exist in the literature that can enhance sampling considerably, and increasingly sophisticated, effective algorithms continue to be developed at a rapid pace. Implementation of these techniques, however, can be challenging for experts and non-experts alike. There is a clear need for software that provides rapid, reliable, and easy access to a wide range of advanced sampling methods and that facilitates implementation of new techniques as they emerge. Here we present SSAGES, a publicly available Software Suite for Advanced General Ensemble Simulations designed to interface with multiple widely used molecular dynamics simulations packages. SSAGES allows facile application of a variety of enhanced sampling techniques-including adaptive biasing force, string methods, and forward flux sampling-that extract meaningful free energy and transition path data from all-atom and coarse-grained simulations. A noteworthy feature of SSAGES is a user-friendly framework that facilitates further development and implementation of new methods and collective variables. In this work, the use of SSAGES is illustrated in the context of simple representative applications involving distinct methods and different collective variables that are available in the current release of the suite. The code may be found at: https://github.com/MICCoM/SSAGES-public.
Moura-Neto, R S; Mello, I C T; Silva, R; Maette, A P C; Bottino, C G; Woerner, A; King, J; Wendt, F; Budowle, B
2018-01-01
The use of bi-allelic markers such as retrotransposable element insertion polymorphisms or Innuls (for insertion/null) can overcome some limitations of short tandem repeat (STR) loci in typing forensic biological evidence. This study investigated the efficiency of the InnoTyper® 21 Innul markers in an urban admixed population sample in Rio de Janeiro (n = 40) and one highly compromised sample collected as evidence by the Rio de Janeiro police. No significant departures from Hardy-Weinberg equilibrium were detected after the Bonferroni correction (α' ≈ 0.05/20, p < 0.0025), and no significant linkage disequilibrium was observed between markers. Assuming loci independence, the cumulative random match probability (RMP) was 2.3 × 10 -8 . A lower mean Fis value was obtained for this sample population compared with those of three North American populations (African-American, Southwest Hispanic, US Caucasian). Principal component analysis with the three North American populations and one from 21 East Asian population showed that African Americans segregated as an independent group while US Caucasian, Southwest Hispanic, East Asian, and Rio de Janeiro populations are in a single large heterogeneous group. Also, a full Innuls profile was produced from an evidence sample, despite the DNA being highly degraded. In conclusion, this system is a useful complement to standard STR kits.
Ke, Peifeng; Liu, Jiawei; Chao, Yan; Wu, Xiaobin; Xiong, Yujuan; Lin, Li; Wan, Zemin; Wu, Xinzhong; Xu, Jianhua; Zhuang, Junhua; Huang, Xianzhang
2017-01-01
Introduction Thalassemia could interfere with some assays for haemoglobin A1c (HbA1c) measurement, therefore, it is useful to be able to screen for thalassemia while measuring HbA1c. We used Capillarys 2 Flex Piercing (Capillarys 2FP) HbA1c programme to simultaneously measure HbA1c and screen for thalassemia. Materials and methods Samples from 498 normal controls and 175 thalassemia patients were analysed by Capillarys 2FP HbA1c programme (Sebia, France). For method comparison, HbA1c was quantified by Premier Hb9210 (Trinity Biotech, Ireland) in 98 thalassaemia patients samples. For verification, HbA1c from eight thalassaemia patients was confirmed by IFCC reference method. Results Among 98 thalassaemia samples, Capillarys 2FP did not provide an HbA1c result in three samples with HbH due to the overlapping of HbBart’s with HbA1c fraction; for the remaining 95 thalassaemia samples, Bland-Altman plot showed 0.00 ± 0.35% absolute bias between two systems, and a significant positive bias above 7% was observed only in two HbH samples. The HbA1c values obtained by Capillarys 2FP were consistent with the IFCC targets (relative bias below ± 6%) in all of the eight samples tested by both methods. For screening samples with alpha (α-) thalassaemia silent/trait or beta (β-) thalassemia trait, the optimal HbA2 cut-off values were ≤ 2.2% and > 2.8%, respectively. Conclusions Our results demonstrated the Capillarys 2FP HbA1c system could report an accurate HbA1c value in thalassemia silent/trait, and HbA2 value (≤ 2.2% for α-thalassaemia silent/trait and > 2.8% for β-thalassemia trait) and abnormal bands (HbH and/or HbBart’s for HbH disease, HbF for β-thalassemia) may provide valuable information for screening. PMID:28900367
NASA Astrophysics Data System (ADS)
Murillo, N. M.; van Dishoeck, E. F.; Tobin, J. J.; Fedele, D.
2016-07-01
Context. Multiplicity is common in field stars and among protostellar systems. Models suggest two paths of formation: turbulent fragmentation and protostellar disk fragmentation. Aims: We attempt to find whether or not the coevality frequency of multiple protostellar systems can help to better understand their formation mechanism. The coevality frequency is determined by constraining the relative evolutionary stages of the components in a multiple system. Methods: Spectral energy distributions (SEDs) for known multiple protostars in Perseus were constructed from literature data. Herschel PACS photometric maps were used to sample the peak of the SED for systems with separations ≥7″, a crucial aspect in determining the evolutionary stage of a protostellar system. Inclination effects and the surrounding envelope and outflows were considered to decouple source geometry from evolution. This together with the shape and derived properties from the SED was used to determine each system's coevality as accurately as possible. SED models were used to examine the frequency of non-coevality that is due to geometry. Results: We find a non-coevality frequency of 33 ± 10% from the comparison of SED shapes of resolved multiple systems. Other source parameters suggest a somewhat lower frequency of non-coevality. The frequency of apparent non-coevality that is due to random inclination angle pairings of model SEDs is 17 ± 0.5%. Observations of the outflow of resolved multiple systems do not suggest significant misalignments within multiple systems. Effects of unresolved multiples on the SED shape are also investigated. Conclusions: We find that one-third of the multiple protostellar systems sampled here are non-coeval, which is more than expected from random geometric orientations. The other two-thirds are found to be coeval. Higher order multiples show a tendency to be non-coeval. The frequency of non-coevality found here is most likely due to formation and enhanced by dynamical evolution.
Sertel Şelale, Denİz; Uzun, Meltem
2018-01-01
Inexpensive, rapid, and reliable tests for detecting the presence and drug susceptibility of Mycobacterium tuberculosis complex (MTBC) are urgently needed to control the transmission of tuberculosis. In this study, we aimed to assess the accuracy and speed of the microscopic-observation drug susceptibility (MODS) assay in the identification of MTBC and detection of multidrug resistance. Sputum samples from patients suspected to have tuberculosis were simultaneously tested with MODS and conventional culture [Löwenstein-Jensen (LJ) culture, BACTEC MGIT™ 960 (MGIT) system], and drug susceptibility testing (MGIT system) methods. A total of 331 sputum samples were analyzed. Sensitivity and specificity of MODS assay for detection of MTBC strains were 96% and 98.8%, respectively. MODS assay detected multidrug resistant MTBC isolates with 92.3% sensitivity and 96.6% specificity. Median time to culture positivity was similar for MGIT (8 days) and MODS culture (8 days), but was significantly longer with LJ culture (20 days) (p < 0.0001 for both comparisons). Median time to availability of the susceptibility results was significantly (p < 0.0001) shorter with MODS assay (8 days) than MGIT system (20 days). In conclusion, MODS is an inexpensive and rapid test with good performance characteristics for direct diagnosis of tuberculosis and detection of multidrug resistance. © 2017 APMIS. Published by John Wiley & Sons Ltd.
Analyzing shear band formation with high resolution X-ray diffraction
Pagan, Darren C.; Obstalecki, Mark; Park, Jun-Sang; ...
2018-01-10
Localization of crystallographic slip into shear bands during uniaxial compression of a copper single crystal is studied using very far-field high-energy diffraction microscopy (vff-HEDM). Diffracted intensity was collected in-situ as the crystal deformed using a unique mobile detector stage that provided access to multiple diffraction peaks with high-angular resolution. From the diffraction data, single crystal orientation pole figures (SCPFs) were generated and are used to track the evolution of the distribution of lattice orientation that develops as slip localizes. To aid the identification of ‘signatures’ of shear band formation and analyze the SCPF data, a model of slip-driven lattice reorientationmore » within shear bands is introduced. Confidence is built in conclusions drawn from the SCPF data about the character of internal slip localization through comparisons with strain fields on the sample surface measured simultaneously using digital image correlation. From the diffraction data, we find that the active slip direction and slip plane are not directly aligned with the orientation of the shear bands that formed. In fact, by extracting the underlying slip system activity from the SCPF data, we show that intersecting shear bands measured on the surface of the sample arise from slip primarily on the same underlying single slip system. These new vff-HEDM results raise significant questions on the use of surface measurements for slip system activity estimation.« less
Ontology-based, Tissue MicroArray oriented, image centered tissue bank
Viti, Federica; Merelli, Ivan; Caprera, Andrea; Lazzari, Barbara; Stella, Alessandra; Milanesi, Luciano
2008-01-01
Background Tissue MicroArray technique is becoming increasingly important in pathology for the validation of experimental data from transcriptomic analysis. This approach produces many images which need to be properly managed, if possible with an infrastructure able to support tissue sharing between institutes. Moreover, the available frameworks oriented to Tissue MicroArray provide good storage for clinical patient, sample treatment and block construction information, but their utility is limited by the lack of data integration with biomolecular information. Results In this work we propose a Tissue MicroArray web oriented system to support researchers in managing bio-samples and, through the use of ontologies, enables tissue sharing aimed at the design of Tissue MicroArray experiments and results evaluation. Indeed, our system provides ontological description both for pre-analysis tissue images and for post-process analysis image results, which is crucial for information exchange. Moreover, working on well-defined terms it is then possible to query web resources for literature articles to integrate both pathology and bioinformatics data. Conclusions Using this system, users associate an ontology-based description to each image uploaded into the database and also integrate results with the ontological description of biosequences identified in every tissue. Moreover, it is possible to integrate the ontological description provided by the user with a full compliant gene ontology definition, enabling statistical studies about correlation between the analyzed pathology and the most commonly related biological processes. PMID:18460177
MAGNETIC BEHAVIOR OF FUNCTIONALLY MODIFIED SPINEL Ni0.4Ca0.6Fe2O4 NANOFERRITE
NASA Astrophysics Data System (ADS)
Prasad, Arun S.; Dhawan, M. S.; Dolia, S. N.; Samariya, Arvind; Reddy, V. R.; Singhal, R. K.; Predeep, P.
2011-06-01
The editorial board discovered that the data points in several sections of the Mossbauer spectra as given in Figs. 3(a) and 3(b) are exactly identical. This is impossible and nonphysical for the measurement of two different samples (or for that matter not even for the same sample!). The only conclusion we can draw from this figure is that some of the data is fabricated. As a result, the results and conclusions as described in the paper are unacceptable. This article is retracted from its publication in Int. J. Mod. Phys. B.
Jumping to conclusions and persecutory delusions.
Startup, Helen; Freeman, Daniel; Garety, Philippa A
2008-09-01
It is unknown whether a 'jumping to conclusions' (JTC) data-gathering bias is apparent in specific delusion sub-types. A group with persecutory delusions is compared with a sample of non-clinical controls on a probabilistic reasoning task. Results suggest JTC is apparent in individuals with the persecutory sub-type of delusions.
Gas chromatographic analysis of volatiles in fluid and gas inclusions.
Andrawes, F; Holzer, G; Roedder, E; Gibson, E K; Oro, J
1984-01-01
Most geological samples and some synthetic materials contain fluid inclusions. These inclusions preserve for us tiny samples of the liquid and/or the gas phase that was present during formation, although in some cases they may have undergone significant changes from the original material. Studies of the current composition of the inclusions provide data on both the original composition and the change since trapping. These conclusions are seldom larger than 1 millimeter in diameter. The composition varies from a single major compound (e.g., water) in a single phase to a very complex mixture in one or more phases. The concentration of some of the compounds present may be at trace levels. We present here some analyses of inclusion on a variety of geological samples, including diamonds. We used a sample crusher and a gas chromatography-mass spectrometry (GC-MS) system to analyze for organic and inorganic volatiles present as major to trace constituents in inclusions. The crusher is a hardened stainless-steel piston cylinder apparatus with tungsten carbide crushing surfaces, and is operated in a pure helium atmosphere at a controlled temperature. Samples ranging from 1 mg to 1 g were crushed and the released volatiles were analyzed using multi-chromatographic columns and detectors, including the sensitive helium ionization detector. Identification of the GC peaks was carried out by GC-MS. This combination of procedures has been shown to provide geochemically useful information on the processes involved in the history of the samples analyzed.
Konzen, Kevin; Brey, Richard
2012-05-01
²²²Rn (radon) and ²²⁰Rn (thoron) progeny are known to interfere with determining the presence of long-lived transuranic radionuclides, such as plutonium and americium, and require from several hours up to several days for conclusive results. Methods are proposed that should expedite the analysis of air samples for determining the amount of transuranic radionuclides present using low-resolution alpha spectroscopy systems available from typical alpha continuous air monitors (CAMs) with multi-channel analyzer (MCA) capabilities. An alpha spectra simulation program was developed in Microsoft Excel visual basic that employed the use of Monte Carlo numerical methods and serial-decay differential equations that resembled actual spectra. Transuranic radionuclides were able to be quantified with statistical certainty by applying peak fitting equations using the method of least squares. Initial favorable results were achieved when samples containing radon progeny were decayed 15 to 30 min, and samples containing both radon and thoron progeny were decayed at least 60 min. The effort indicates that timely decisions can be made when determining transuranic activity using available alpha CAMs with alpha spectroscopy capabilities for counting retrospective air samples if accompanied by analyses that consider the characteristics of serial decay.
The effect of magnesium ions on chromosome structure as observed by helium ion microscopy.
Dwiranti, Astari; Hamano, Tohru; Takata, Hideaki; Nagano, Shoko; Guo, Hongxuan; Onishi, Keiko; Wako, Toshiyuki; Uchiyama, Susumu; Fukui, Kiichi
2014-02-01
One of the few conclusions known about chromosome structure is that Mg2+ is required for the organization of chromosomes. Scanning electron microscopy is a powerful tool for studying chromosome morphology, but being nonconductive, chromosomes require metal/carbon coating that may conceal information about the detailed surface structure of the sample. Helium ion microscopy (HIM), which has recently been developed, does not require sample coating due to its charge compensation system. Here we investigated the structure of isolated human chromosomes under different Mg2+ concentrations by HIM. High-contrast and resolution images from uncoated samples obtained by HIM enabled investigation on the effects of Mg2+ on chromosome structure. Chromatin fiber information was obtained more clearly with uncoated than coated chromosomes. Our results suggest that both overall features and detailed structure of chromatin are significantly affected by different Mg2+ concentrations. Chromosomes were more condensed and a globular structure of chromatin with 30 nm diameter was visualized with 5 mM Mg2+ treatment, while 0 mM Mg2+ resulted in a less compact and more fibrous structure 11 nm in diameter. We conclude that HIM is a powerful tool for investigating chromosomes and other biological samples without requiring metal/carbon coating.
Abela, Jo Etienne; Skeldon, Kenneth D; Stuart, Robert C; Padgett, Miles J
2009-06-01
There has been growing interest in the measurement of breath ethane as an optimal non-invasive marker of oxidative stress. High concentrations of various breath alkanes including ethane have been reported in a number of malignancies. Our aim was to investigate the use of novel laser spectroscopy for rapid reporting of exhaled ethane and to determine whether breath ethane concentration is related to a diagnosis of upper gastrointestinal malignancy. Two groups of patients were recruited. Group A (n = 20) had a histo-pathological diagnosis of either esophageal or gastric malignancy. Group B (n = 10) was made up of healthy controls. Breath samples were collected from these subjects and the ethane concentration in these samples was subsequently measured to an accuracy of 0.2 parts per billion, ppb. Group A patients had a corrected exhaled breath ethane concentration of 2.3 +/- 0.8 (mean +/- SEM) ppb. Group B patients registered a mean of 3.1 +/- 0.5 ppb. There was no statistically significant difference between the two groups (p = 0.39). In conclusion, concentrations of ethane in collected breath samples were not significantly elevated in upper gastrointestinal malignancy. The laser spectroscopy system provided a reliable and rapid turnaround for breath sample analysis.
Impact of cryopreservation on tetramer, cytokine flow cytometry, and ELISPOT
Maecker, Holden T; Moon, James; Bhatia, Sonny; Ghanekar, Smita A; Maino, Vernon C; Payne, Janice K; Kuus-Reichel, Kristine; Chang, Jennie C; Summers, Amanda; Clay, Timothy M; Morse, Michael A; Lyerly, H Kim; DeLaRosa, Corazon; Ankerst, Donna P; Disis, Mary L
2005-01-01
Background Cryopreservation of PBMC and/or overnight shipping of samples are required for many clinical trials, despite their potentially adverse effects upon immune monitoring assays such as MHC-peptide tetramer staining, cytokine flow cytometry (CFC), and ELISPOT. In this study, we compared the performance of these assays on leukapheresed PBMC shipped overnight in medium versus cryopreserved PBMC from matched donors. Results Using CMV pp65 peptide pool stimulation or pp65 HLA-A2 tetramer staining, there was significant correlation between shipped and cryopreserved samples for each assay (p ≤ 0.001). The differences in response magnitude between cryopreserved and shipped PBMC specimens were not significant for most antigens and assays. There was significant correlation between CFC and ELISPOT assay using pp65 peptide pool stimulation, in both shipped and cryopreserved samples (p ≤ 0.001). Strong correlation was observed between CFC (using HLA-A2-restricted pp65 peptide stimulation) and tetramer staining (p < 0.001). Roughly similar sensitivity and specificity were observed between the three assays and between shipped and cryopreserved samples for each assay. Conclusion We conclude that all three assays show concordant results on shipped versus cryopreserved specimens, when using a peptide-based readout. The assays are also concordant with each other in pair wise comparisons using equivalent antigen systems. PMID:16026627
A comprehensive characterization of rare mitochondrial DNA variants in neuroblastoma
Pignataro, Piero; Lasorsa, Vito Alessandro; Hogarty, Michael D.; Castellano, Aurora; Conte, Massimo; Tonini, Gian Paolo; Iolascon, Achille; Gasparre, Giuseppe; Capasso, Mario
2016-01-01
Background Neuroblastoma, a tumor of the developing sympathetic nervous system, is a common childhood neoplasm that is often lethal. Mitochondrial DNA (mtDNA) mutations have been found in most tumors including neuroblastoma. We extracted mtDNA data from a cohort of neuroblastoma samples that had undergone Whole Exome Sequencing (WES) and also used snap-frozen samples in which mtDNA was entirely sequenced by Sanger technology. We next undertook the challenge of determining those mutations that are relevant to, or arisen during tumor development. The bioinformatics pipeline used to extract mitochondrial variants from matched tumor/blood samples was enriched by a set of filters inclusive of heteroplasmic fraction, nucleotide variability, and in silico prediction of pathogenicity. Results Our in silico multistep workflow applied both on WES and Sanger-sequenced neuroblastoma samples, allowed us to identify a limited burden of somatic and germline mitochondrial mutations with a potential pathogenic impact. Conclusions The few singleton germline and somatic mitochondrial mutations emerged, according to our in silico analysis, do not appear to impact on the development of neuroblastoma. Our findings are consistent with the hypothesis that most mitochondrial somatic mutations can be considered as ‘passengers’ and consequently have no discernible effect in this type of cancer. PMID:27351283
Overweight and the feline gut microbiome - a pilot study.
Kieler, I N; Mølbak, L; Hansen, L L; Hermann-Bank, M L; Bjornvad, C R
2016-06-01
Compared with lean humans, the gut microbiota is altered in the obese. Whether these changes are due to an obesogenic diet, and whether the microbiota contributes to adiposity is currently discussed. In the cat population, where obesity is also prevalent, gut microbiome changes associated with obesity have not been studied. Consequently, the aim of this study was to compare the gut microbiota of lean cats, with that of overweight and obese cats. Seventy-seven rescue-shelter cats housed for ≥3 consecutive days were included in the study. Faecal samples were obtained by rectal swab and, when available, by a paired litter box sample. Body condition was assessed using a 9-point scoring system. DNA was extracted, and the 16S rRNA gene was amplified with a high-throughput quantitative real-time PCR chip. Overweight and obese cats had a significantly different gut microbiota compared to lean cats (p < 0.05), but this finding could not be linked to differences in specific bacterial groups. The rectal samples obtained higher DNA concentration than litter box samples (p < 0.0001). In conclusion, overweight and obese cats seem to have an altered gut microbiome as compared to lean cats. Journal of Animal Physiology and Animal Nutrition © 2015 Blackwell Verlag GmbH.
Goode, Angela E.; Skepper, Jeremy N.; Thorley, Andrew J.; Seiffert, Joanna M.; Chung, K. Fan; Tetley, Teresa D.; Shaffer, Milo S. P.; Ryan, Mary P.
2015-01-01
Electron microscopy has been applied widely to study the interaction of nanomaterials with proteins, cells and tissues at nanometre scale. Biological material is most commonly embedded in thermoset resins to make it compatible with the high vacuum in the electron microscope. Room temperature sample preparation protocols developed over decades provide contrast by staining cell organelles, and aim to preserve the native cell structure. However, the effect of these complex protocols on the nanomaterials in the system is seldom considered. Any artefacts generated during sample preparation may ultimately interfere with the accurate prediction of the stability and reactivity of the nanomaterials. As a case study, we review steps in the room temperature preparation of cells exposed to silver nanomaterials (AgNMs) for transmission electron microscopy imaging and analysis. In particular, embedding and staining protocols, which can alter the physicochemical properties of AgNMs and introduce artefacts thereby leading to a misinterpretation of silver bioreactivity, are scrutinised. Recommendations are given for the application of cryogenic sample preparation protocols, which simultaneously fix both particles and diffusible ions. By being aware of the advantages and limitations of different sample preparation methods, compromises or selection of different correlative techniques can be made to draw more accurate conclusions about the data. PMID:25606708
Genetic analysis of 7 medieval skeletons from Aragonese Pyrenees
Núńez, Carolina; Sosa, Cecilia; Baeta, Miriam; Geppert, Maria; Turnbough, Meredith; Phillips, Nicole; Casalod, Yolanda; Bolea, Miguel; Roby, Rhonda; Budowle, Bruce; Martínez-Jarreta, Begońa
2011-01-01
Aim To perform a genetic characterization of 7 skeletons from medieval age found in a burial site in the Aragonese Pyrenees. Methods Allele frequencies of autosomal short tandem repeats (STR) loci were determined by 3 different STR systems. Mitochondrial DNA (mtDNA) and Y-chromosome haplogroups were determined by sequencing of the hypervariable segment 1 of mtDNA and typing of phylogenetic Y chromosome single nucleotide polymorphisms (Y-SNP) markers, respectively. Possible familial relationships were also investigated. Results Complete or partial STR profiles were obtained in 3 of the 7 samples. Mitochondrial DNA haplogroup was determined in 6 samples, with 5 of them corresponding to the haplogroup H and 1 to the haplogroup U5a. Y-chromosome haplogroup was determined in 2 samples, corresponding to the haplogroup R. In one of them, the sub-branch R1b1b2 was determined. mtDNA sequences indicated that some of the individuals could be maternally related, while STR profiles indicated no direct family relationships. Conclusions Despite the antiquity of the samples and great difficulty that genetic analyses entail, the combined use of autosomal STR markers, Y-chromosome informative SNPs, and mtDNA sequences allowed us to genotype a group of skeletons from the medieval age. PMID:21674829
Service Providers’ Experiences and Perspectives on Recovery-Oriented Mental Health System Reform
Piat, Myra; Lal, Shalini
2016-01-01
Objective With the use of a qualitative approach, this study focuses on service providers’ experiences and perspectives on recovery-oriented reform. Methods Nine focus groups were conducted with a sample of 68 service providers recruited from three Canadian sites. Results Three major themes were identified: 1) positive attitudes towards recovery-oriented reform; 2) skepticism towards recovery-oriented reform; and 3) challenges associated with implementing recovery-oriented practice. These challenges pertained to conceptual uncertainty and consistency around the meanings of recovery; application of recovery-oriented practice with certain populations and in certain contexts; bureaucratization of recovery-oriented tools; limited leadership support; and, societal stigma and social exclusion of persons with mental illnesses. Conclusions and Implications for Practice The findings point towards challenges that might arise as system planners move ahead in their efforts toward implementing recovery within the mental health system. In this regard, we offer several recommendations for the planning of organizational and educational practices that support the implementation of recovery-oriented practice. PMID:22491368
A shape memory polymer concrete crack closure system activated by electrical current
NASA Astrophysics Data System (ADS)
Teall, Oliver; Pilegis, Martins; Davies, Robert; Sweeney, John; Jefferson, Tony; Lark, Robert; Gardner, Diane
2018-07-01
The presence of cracks has a negative impact on the durability of concrete by providing paths for corrosive materials to the embedded steel reinforcement. Cracks in concrete can be closed using shape memory polymers (SMP) which produce a compressive stress across the crack faces. This stress has been previously found to enhance the load recovery associated with autogenous self-healing. This paper details the experiments undertaken to incorporate SMP tendons containing polyethylene terephthalate (PET) filaments into reinforced and unreinforced 500 × 100 × 100 mm structural concrete beam samples. These tendons are activated via an electrical supply using a nickel-chrome resistance wire heating system. The set-up, methodology and results of restrained shrinkage stress and crack closure experiments are explained. Crack closure of up to 85% in unreinforced beams and 26%–39% in reinforced beams is measured using crack-mouth opening displacement, microscope and digital image correlation equipment. Conclusions are made as to the effectiveness of the system and its potential for application within industry.
Reporting vaccine-associated adverse events.
Duclos, P.; Hockin, J.; Pless, R.; Lawlor, B.
1997-01-01
OBJECTIVE: To determine family physicians' awareness of the need to monitor and report vaccine-associated adverse events (VAAE) in Canada and to identify mechanisms that could facilitate reporting. DESIGN: Mailed survey. SETTING: Canadian family practices. PARTICIPANTS: Random sample of 747 family physicians. Overall response rate was 32% (226 of 717 eligible physicians). MAIN OUTCOME MEASURES: Access to education on VAAE; knowledge about VAAE monitoring systems, reporting criteria, and reporting forms; method of reporting VAAEs and reasons for not reporting them; and current experience with VAAEs. RESULTS: Of 226 respondents, 55% reported observing VAAEs, and 42% reported the event. Fewer than 50% were aware of a monitoring system for VAAE, and only 39% had had VAAE-related education during medical training. Only 28% knew the reporting criteria. Reporting was significantly associated with knowledge of VAAE monitoring systems and reporting criteria (P < 0.01). CONCLUSION: Physicians need more feedback and education on VAAE reporting and more information about the importance of reporting and about reporting criteria and methods. PMID:9303234
Metabolism of triacetin-derived acetate in dogs.
Bleiberg, B; Beers, T R; Persson, M; Miles, J M
1993-12-01
Triacetin is a water-soluble triglyceride that may have a role as a parenteral nutrient. In the present study triacetin was administered intravenously to mongrel dogs (n = 10) 2 wk after surgical placement of blood-sampling catheters in the aorta and in the portal, hepatic, renal, and femoral veins. [1-14C]Acetate was infused to allow quantification of organ uptake of acetate as well as systemic turnover and oxidation. Systemic acetate turnover accounted for approximately 70% of triacetin-derived acetate, assuming complete hydrolysis of the triglyceride. Approximately 80% of systemic acetate uptake was rapidly oxidized. Significant acetate uptake was demonstrated in all tissues (liver, 559 +/- 68; intestine, 342 +/- 23; hindlimb, 89 +/- 7; and kidney, 330 +/- 37 mumol/min). In conclusion, during intravenous administration in dogs, the majority of infused triacetin undergoes intravascular hydrolysis, and the majority of the resulting acetate is oxidized. Thus, energy in the form of short-chain fatty acids can be delivered to a resting gut via intravenous infusion of a short-chain triglyceride.
Eadie, Leila H; Taylor, Paul; Gibson, Adam P
2012-04-01
Computer-assisted diagnosis (CAD) describes a diverse, heterogeneous range of applications rather than a single entity. The aims and functions of CAD systems vary considerably and comparing studies and systems is challenging due to methodological and design differences. In addition, poor study quality and reporting can reduce the value of some publications. Meta-analyses of CAD are therefore difficult and may not provide reliable conclusions. Aiming to determine the major sources of heterogeneity and thereby what CAD researchers could change to allow this sort of assessment, this study reviews a sample of 147 papers concerning CAD used with imaging for cancer diagnosis. It discusses sources of variability, including the goal of the CAD system, learning methodology, study population, design, outcome measures, inclusion of radiologists, and study quality. Based upon this evidence, recommendations are made to help researchers optimize the quality and comparability of their trial design and reporting. Copyright © 2011 Elsevier Inc. All rights reserved.
St. Onge, K. R.; Palmé, A. E.; Wright, S. I.; Lascoux, M.
2012-01-01
Most species have at least some level of genetic structure. Recent simulation studies have shown that it is important to consider population structure when sampling individuals to infer past population history. The relevance of the results of these computer simulations for empirical studies, however, remains unclear. In the present study, we use DNA sequence datasets collected from two closely related species with very different histories, the selfing species Capsella rubella and its outcrossing relative C. grandiflora, to assess the impact of different sampling strategies on summary statistics and the inference of historical demography. Sampling strategy did not strongly influence the mean values of Tajima’s D in either species, but it had some impact on the variance. The general conclusions about demographic history were comparable across sampling schemes even when resampled data were analyzed with approximate Bayesian computation (ABC). We used simulations to explore the effects of sampling scheme under different demographic models. We conclude that when sequences from modest numbers of loci (<60) are analyzed, the sampling strategy is generally of limited importance. The same is true under intermediate or high levels of gene flow (4Nm > 2–10) in models in which global expansion is combined with either local expansion or hierarchical population structure. Although we observe a less severe effect of sampling than predicted under some earlier simulation models, our results should not be seen as an encouragement to neglect this issue. In general, a good coverage of the natural range, both within and between populations, will be needed to obtain a reliable reconstruction of a species’s demographic history, and in fact, the effect of sampling scheme on polymorphism patterns may itself provide important information about demographic history. PMID:22870403
Ehler, Edvard; Vaněk, Daniel; Stenzl, Vlastimil; Vančata, Václav
2011-01-01
Aim To evaluate Y-chromosomal diversity of the Moravian Valachs of the Czech Republic and compare them with a Czech population sample and other samples from Central and South-Eastern Europe, and to evaluate the effects of genetic isolation and sampling. Methods The first sample set of the Valachs consisted of 94 unrelated male donors from the Valach region in northeastern Czech Republic border-area. The second sample set of the Valachs consisted of 79 men who originated from 7 paternal lineages defined by surname. No close relatives were sampled. The third sample set consisted of 273 unrelated men from the whole of the Czech Republic and was used for comparison, as well as published data for other 27 populations. The total number of samples was 3244. Y-short tandem repeat (STR) markers were typed by standard methods using PowerPlex® Y System (Promega) and Yfiler® Amplification Kit (Applied Biosystems) kits. Y-chromosomal haplogroups were estimated from the haplotype information. Haplotype diversity and other intra- and inter-population statistics were computed. Results The Moravian Valachs showed a lower genetic variability of Y-STR markers than other Central European populations, resembling more to the isolated Balkan populations (Aromuns, Csango, Bulgarian, and Macedonian Roma) than the surrounding populations (Czechs, Slovaks, Poles, Saxons). We illustrated the effect of sampling on Valach paternal lineages, which includes reduction of discrimination capacity and variability inside Y-chromosomal haplogroups. Valach modal haplotype belongs to R1a haplogroup and it was not detected in the Czech population. Conclusion The Moravian Valachs display strong substructure and isolation in their Y chromosomal markers. They represent a unique Central European population model for population genetics. PMID:21674832
Prevalence of coccidiosis among village and exotic breed of chickens in Maiduguri, Nigeria
Lawal, Jallailudeen Rabana; Jajere, Saleh Mohammed; Ibrahim, Umar Isa; Geidam, Yaqub Ahmed; Gulani, Isa Adamu; Musa, Gambo; Ibekwe, Benjamin U.
2016-01-01
Aim: Coccidiosis is an important enteric parasitic disease of poultry associated with significant economic losses to poultry farmers worldwide. This survey was conducted from June 2014 through July 2015 with the main goal of investigating the prevalence and associated risk factors of coccidiosis among village and exotic breeds of chickens in Maiduguri, Northeastern Nigeria. Materials and Methods: A total of 600 fecal samples from live and slaughtered birds comprising 284 young, 141, growers and 175 adult birds; 379 male and 221 female birds; 450 exotic and 150 local breeds of birds were randomly collected either as bird’s fresh droppings or cutting open an eviscerated intestine of slaughtered birds, while noting their age, sex, and breeds. Samples were analyzed using standard parasitological methods and techniques. Results: An overall prevalence rate of 31.8% (95% confidence interval: 28.07-35.52) was obtained. Higher prevalence rates were recorded in growing birds 58.9% (50.78-67.02), female birds 35.3% (29.00-41.60), exotic birds 42.4% (37.83-46.97), and broiler birds 68.7% (61.28-76.12). Similarly, higher infection rates were also observed among birds sampled from Mairi ward 66.7% (56.03-77.37), intensive management system 46.5% (41.61-51.39), and constructed local cages 54.0% (46.02-61.98). The difference in prevalence of coccidiosis among age groups, breeds, among exotic breeds, sampling sites, husbandry management systems, and litter management systems was statistically significant (<0.0001). However, no significant difference (p>0.05) of infection rates was observed in sex. Conclusion: Coccidiosis is endemic in both commercial and backyard poultry farms in Maiduguri due to poor management practices encouraging Eimeria oocysts build-up. It is therefore, recommended that poultry farmers should practice strict biosecurity measures on their farms, creating awareness on the prevalence of coccidiosis, routine vaccination against coccidiosis and educating poultry farmers on the need for maintaining good hygienic standards and good flock health management. PMID:27397991
Effects of different agricultural systems on soil quality in Northern Limón province, Costa Rica.
Cornwell, Emma
2014-09-01
Conversion of native rainforest ecosystems in Limón Province of Costa Rica to banana and pineapple monoculture has led to reductions in biodiversity and soil quality. Agroforestry management of cacao (Theobroma cacao) is an alternative system that may maintain the agricultural livelihood of the region while more closely mimicking native ecosystems. This study compared physical, biological and chemical soil quality indicators of a cacao plantation under organic agroforestry management with banana, pineapple, and pasture systems; a native forest nearby served as a control. For bulk density and earthworm analysis, 18 samples were collected between March and April 2012 from each ecosystem paired with 18 samples from the cacao. Cacao had a lower bulk density than banana and pineapple monocultures, but greater than the forest (p < 0.05). Cacao also hosted a greater number and mass of earthworms than banana and pineapple (p < 0.05), but similar to forest and pasture. For soil chemical characteristics, three composite samples were collected in March 2012 from each agroecosystem paired with three samples from the cacao plantation. Forest and pineapple ecosystems had the lowest pH, cation exchange capacity, and exchangeable nutrient cations, while cacao had the greatest (p < 0.05). Total nutrient levels of P and N were slightly greater in banana, pineapple and pasture than in cacao; probably related to addition of chemical fertilizer and manure from cattle grazing. Forest and cacao also had greater %C, than other ecosystems, which is directly related to soil organic matter content (p < 0.0001). Overall, cacao had more favorable physical, biological and chemical soil characteristics than banana and pineapple monocultures, while trends were less conclusive compared to the pastureland. While organic cacao was inferior to native forest in some soil characteristics such as bulk density and organic carbon, its soil quality did best mimic that of the native forest. This supports the organic cultivation of cacao as a desirable alternative to banana and pineapple monoculture.
Beyer, Andreas; Grohganz, Holger; Löbmann, Korbinian; Rades, Thomas; Leopold, Claudia S
2016-12-01
Co-amorphization represents a promising approach to increase the physical stability and dissolution rate of amorphous active pharmaceutical ingredients (APIs) as an alternative to polymer glass solutions. For amorphous and co-amorphous systems, it is reported that the preparation method and the blend ratio play major roles with regard to the resulting physical stability. Therefore, in the present study, co-amorphous naproxen-indomethacin (NAP/IND) was prepared by melt-quenching at three different cooling rates and at ten different NAP/IND blend ratios. The samples were analyzed using XRPD and FTIR, both directly after preparation and during storage to investigate their physical stabilities. All cooling methods led to fully amorphous samples, but with significantly different physical stabilities. Samples prepared by fast cooling had a higher degree of crystallinity after 300d of storage than samples prepared by intermediate cooling and slow cooling. Intermediate cooling was subsequently used to prepare co-amorphous NAP/IND at different blend ratios. In a previous study, it was postulated that the equimolar (0.5:0.5) co-amorphous blend of NAP/IND is most stable. However, in the present study the physically most stable blend was found for a NAP/IND ratio of 0.6:0.4, which also represents the eutectic composition of the crystalline NAP/γ-IND system. This indicates that the eutectic point may be of major importance for the stability of binary co-amorphous systems. Slight deviations from the optimal naproxen molar fraction led to significant recrystallization during storage. Either naproxen or γ-indomethacin recrystallized until a naproxen molar fraction of about 0.6 in the residual co-amorphous phase was reached again. In conclusion, the physical stability of co-amorphous NAP/IND may be significantly improved, if suitable preparation conditions and the optimal phase composition are chosen. Copyright © 2016 Elsevier B.V. All rights reserved.
Policy and System Change and Community Coalitions: Outcomes From Allies Against Asthma
Lachance, Laurie; Doctor, Linda Jo; Gilmore, Lisa; Kelly, Cindy; Krieger, James; Lara, Marielena; Meurer, John; Friedman Milanovich, Amy; Nicholas, Elisa; Rosenthal, Michael; Stoll, Shelley C.; Wilkin, Margaret
2010-01-01
Objectives. We assessed policy and system changes and health outcomes produced by the Allies Against Asthma program, a 5-year collaborative effort by 7 community coalitions to address childhood asthma. We also explored associations between community engagement and outcomes. Methods. We interviewed a sample of 1477 parents of children with asthma in coalition target areas and comparison areas at baseline and 1 year to assess quality-of-life and symptom changes. An extensive tracking and documentation procedure and a survey of 284 participating individuals and organizations were used to ascertain policy and system changes and community engagement levels. Results. A total of 89 policy and system changes were achieved, ranging from changes in interinstitutional and intrainstitutional practices to statewide legislation. Allies children experienced fewer daytime (P = .008) and nighttime (P = .004) asthma symptoms than comparison children. In addition, Allies parents felt less helpless, frightened, and angry (P = .01) about their child's asthma. Type of community engagement was associated with number of policy and system changes. Conclusions. Community coalitions can successfully achieve asthma policy and system changes and improve health outcomes. Increased core and ongoing community stakeholder participation rather than a higher overall number of participants was associated with more change. PMID:20299641
Foucaud, J; Estoup, A; Loiseau, A; Rey, O; Orivel, J
2010-08-01
Previous studies indicate that some populations of the little fire ant, Wasmannia auropunctata, display an unusual reproduction system polymorphism. Although some populations have a classical haplodiploid reproduction system, in other populations queens are produced by thelytokous parthenogenesis, males are produced by a male clonality system and workers are produced sexually. An atypical genetic caste determination system was also suggested. However, these conclusions were indirectly inferred from genetic studies on field population samples. Here we set up experimental laboratory nests that allow the control of the parental relationships between individuals. The queens heading those nests originated from either putatively clonal or sexual populations. We characterized the male, queen and worker offspring they produced at 12 microsatellite loci. Our results unambiguously confirm the unique reproduction system polymorphism mentioned above and that male clonality is strictly associated with thelytokous parthenogenesis. We also observed direct evidence of the rare production of sexual gynes and arrhenotokous males in clonal populations. Finally, we obtained evidence of a genetic basis for caste determination. The evolutionary significance of the reproduction system polymorphism and genetic caste determination as well as future research opportunities are discussed.
Mörsdorf, Martin A; Ravolainen, Virve T; Støvern, Leif Einar; Yoccoz, Nigel G; Jónsdóttir, Ingibjörg Svala; Bråthen, Kari Anne
2015-01-01
In ecology, expert knowledge on habitat characteristics is often used to define sampling units such as study sites. Ecologists are especially prone to such approaches when prior sampling frames are not accessible. Here we ask to what extent can different approaches to the definition of sampling units influence the conclusions that are drawn from an ecological study? We do this by comparing a formal versus a subjective definition of sampling units within a study design which is based on well-articulated objectives and proper methodology. Both approaches are applied to tundra plant communities in mesic and snowbed habitats. For the formal approach, sampling units were first defined for each habitat in concave terrain of suitable slope using GIS. In the field, these units were only accepted as the targeted habitats if additional criteria for vegetation cover were fulfilled. For the subjective approach, sampling units were defined visually in the field, based on typical plant communities of mesic and snowbed habitats. For each approach, we collected information about plant community characteristics within a total of 11 mesic and seven snowbed units distributed between two herding districts of contrasting reindeer density. Results from the two approaches differed significantly in several plant community characteristics in both mesic and snowbed habitats. Furthermore, differences between the two approaches were not consistent because their magnitude and direction differed both between the two habitats and the two reindeer herding districts. Consequently, we could draw different conclusions on how plant diversity and relative abundance of functional groups are differentiated between the two habitats depending on the approach used. We therefore challenge ecologists to formalize the expert knowledge applied to define sampling units through a set of well-articulated rules, rather than applying it subjectively. We see this as instrumental for progress in ecology as only rules based on expert knowledge are transparent and lead to results reproducible by other ecologists.
Cope, Jennifer R.; Ratard, Raoult C.; Hill, Vincent R.; Sokol, Theresa; Causey, Jonathan Jake; Yoder, Jonathan S.; Mirani, Gayatri; Mull, Bonnie; Mukerjee, Kimberly A.; Narayanan, Jothikumar; Doucet, Meggie; Qvarnstrom, Yvonne; Poole, Charla N.; Akingbola, Olugbenga A.; Ritter, Jana; Xiong, Zhenggang; da Silva, Alexandre; Roellig, Dawn; Van Dyke, Russell; Stern, Harlan; Xiao, Lihua; Beach, Michael J.
2015-01-01
Background Naegleria fowleri is a climate-sensitive, thermophilic ameba found in warm, freshwater lakes and rivers. Primary amebic meningoencephalitis (PAM), which is almost universally fatal, occurs when N. fowleri–containing water enters the nose, typically during swimming, and N. fowleri migrates to the brain via the olfactory nerve. In August 2013, a 4-year-old child died of meningoencephalitis of unknown etiology in a Louisiana hospital. Methods Clinical and environmental testing and a case investigation were initiated to determine the cause of death and to identify potential exposures. Results Based on testing of CSF and brain specimens, the child was diagnosed with PAM. His only reported water exposure was tap water; in particular, tap water that was used to supply water to a lawn water slide on which the child had played extensively prior to becoming ill. Water samples were collected from both the home and the water distribution system that supplied the home and tested; N. fowleri were identified in water samples from both the home and the water distribution system. Conclusions This case is the first reported PAM death associated with culturable N. fowleri in tap water from a U.S. treated drinking water system. This case occurred in the context of an expanding geographic range for PAM beyond southern tier states with recent case reports from Minnesota, Kansas, and Indiana. This case also highlights the role of adequate disinfection throughout drinking water distribution systems and the importance of maintaining vigilance when operating drinking water systems using source waters with elevated temperatures. PMID:25595746
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manohar, N; Diagaradjane, P; Krishnan, S
2016-06-15
Purpose: To demonstrate the ability to perform high-resolution imaging and quantification of sparse distributions of gold nanoparticles (GNPs) within ex vivo tumor samples using a highly-sensitive benchtop L-shell x-ray fluorescence (XRF) imaging system. Methods: An optimized L-shell XRF imaging system was assembled using a tungsten-target x-ray source (operated at 62 kVp and 45 mA). The x-rays were filtered (copper: 0.08 mm & aluminum: 0.04 mm) and collimated (lead: 5 cm thickness, 3 cm aperture diameter) into a cone-beam in order to irradiate small samples or objects. A collimated (stainless steel: 4 cm thickness, 2 mm aperture diameter) silicon drift detector,more » capable of 2D translation, was placed at 90° with respect to the beam to acquire XRF/scatter spectra from regions of interest. Spectral processing involved extracting XRF signal from background, followed by attenuation correction using a Compton scatter-based normalization algorithm. Calibration phantoms with water/GNPs (0 and 0.00001–10 mg/cm{sup 3}) were used to determine the detection limit of the system at a 10-second acquisition time. The system was then used to map the distribution of GNPs within a 12×11×2 mm{sup 3} slice excised from the center of a GNP-loaded ex vivo murine tumor sample; a total of 110 voxels (2.65×10{sup −3} cm{sup 3}) were imaged with 1.3-mm spatial resolution. Results: The detection limit of the current cone-beam benchtop L-shell XRF system was 0.003 mg/cm{sup 3} (3 ppm). Intratumoral GNP concentrations ranging from 0.003 mg/cm{sup 3} (3 ppm) to a maximum of 0.055 mg/cm{sup 3} (55 ppm) and average of 0.0093 mg/cm{sup 3} (9.3 ppm) were imaged successfully within the ex vivo tumor slice. Conclusion: The developed cone-beam benchtop L-shell XRF imaging system can immediately be used for imaging of ex vivo tumor samples containing low concentrations of GNPs. With minor finetuning/optimization, the system can be directly adapted for performing routine preclinical in vivo imaging tasks. Supported by NIH/NCI grant R01CA155446 This investigation was supported by NIH/NCI grant R01CA155446.« less
Civade, Raphaël; Dejean, Tony; Valentini, Alice; Roset, Nicolas; Raymond, Jean-Claude; Bonin, Aurélie; Taberlet, Pierre; Pont, Didier
2016-01-01
In the last few years, the study of environmental DNA (eDNA) has drawn attention for many reasons, including its advantages for monitoring and conservation purposes. So far, in aquatic environments, most of eDNA research has focused on the detection of single species using species-specific markers. Recently, species inventories based on the analysis of a single generalist marker targeting a larger taxonomic group (eDNA metabarcoding) have proven useful for bony fish and amphibian biodiversity surveys. This approach involves in situ filtering of large volumes of water followed by amplification and sequencing of a short discriminative fragment from the 12S rDNA mitochondrial gene. In this study, we went one step further by investigating the spatial representativeness (i.e. ecological reliability and signal variability in space) of eDNA metabarcoding for large-scale fish biodiversity assessment in a freshwater system including lentic and lotic environments. We tested the ability of this approach to characterize large-scale organization of fish communities along a longitudinal gradient, from a lake to the outflowing river. First, our results confirm that eDNA metabarcoding is more efficient than a single traditional sampling campaign to detect species presence, especially in rivers. Second, the species list obtained using this approach is comparable to the one obtained when cumulating all traditional sampling sessions since 1995 and 1988 for the lake and the river, respectively. In conclusion, eDNA metabarcoding gives a faithful description of local fish biodiversity in the study system, more specifically within a range of a few kilometers along the river in our study conditions, i.e. longer than a traditional fish sampling site.
A Survey of Environmental Microbial Flora During Closed Chamber Studies
NASA Technical Reports Server (NTRS)
Ott, C. Mark; Groves, Theron O.; Bell-Robinson, Denetia; Pierson, Duane L.; Paloski, W. H. (Technical Monitor)
1999-01-01
Services, Inc. and NASA Johnson Space Center, Houston, TX As NASA prepares for long-term missions aboard the International Space Station and the eventual exploration of Mars, closed-environment chambers on Earth have become important test beds for systems evaluations. During 2 separate studies of a selfcontained ecosystem containing 4 crewmembers, microbial surveys of samples from 13 surface and 3 air sites were performed. Microbial concentration of samples from surface sites with frequent water contact (e.g., urinal, sink) did not indicate significantly higher levels of contamination than drier areas, though surface cleaning by the crew may have influenced this conclusion. Changes in bacterial diversity on surface sites implied that the number of transient species was high, suggesting movement by crew activities, aerosols, or both. A non-linear relationship between bacterial diversity and enumeration from surface samples indicated that a rapid increase occurred in the number of species as cell concentration increased to 5 CFU/sq cm. Above this concentration, the number of different bacterial species varied between 11 and 16. Airborne bacteria and fungi averaged only 160 and 1 CFU/m3, respectively. Microbial contamination of the potable water system primarily consisted of 3 species of Gram negative bacteria; however, after 60 days during one study, several species of Bacillus became the dominant flora. This study suggests that under these conditions, microbial contamination in the air and water was suppressed by the life-support systems, though contamination was possible. Conversely, the crew and their activities controlled microbial levels on surfaces. Understanding the factors that affect microbial control will improve the design of microbial testing both during space flight and in analogous Earth-based environments.
Rimério, Carla Aparecida Tavares; De Oliveira, Renato Souza; de Almeida Bonatelli, Murilo Queiroz; Nucci, Anamarli; Costa, Sandra Cecília Botelho; Bonon, Sandra Helena Alves
2015-04-01
Infections of the central nervous systems (CNS) present a diagnostic problem for which an accurate laboratory diagnosis is essential. Invasive practices, such as cerebral biopsy, have been replaced by obtaining a polymerase chain reaction (PCR) diagnosis using cerebral spinal fluid (CSF) as a reference method. Tests on DNA extracted from plasma are noninvasive, thus avoiding all of the collateral effects and patient risks associated with CSF collection. This study aimed to determine whether plasma can replace CSF in nested PCR analysis for the detection of CNS human herpesvirus (HHV) diseases by analysing the proportion of patients whose CSF nested PCR results were positive for CNS HHV who also had the same organism identified by plasma nested PCR. In this study, CSF DNA was used as the "gold standard," and nested PCR was performed on both types of samples. Fifty-two patients with symptoms of nervous system infection were submitted to CSF and blood collection. For the eight HHV, one positive DNA result-in plasma and/or CSF nested PCR-was considered an active HHV infection, whereas the occurrence of two or more HHVs in the same sample was considered a coinfection. HHV infections were positively detected in 27/52 (51.9%) of the CSF and in 32/52 (61.5%) of the plasma, difference not significant, thus nested PCR can be performed on plasma instead of CSF. In conclusion, this findings suggest that plasma as a useful material for the diagnosis of cases where there is any difficulty to perform a CSF puncture. © 2015 Wiley Periodicals, Inc.
MetaLIMS, a simple open-source laboratory information management system for small metagenomic labs
Gaultier, Nicolas Paul Eugène; Miller, Dana; Purbojati, Rikky Wenang; Lauro, Federico M.
2017-01-01
Abstract Background: As the cost of sequencing continues to fall, smaller groups increasingly initiate and manage larger sequencing projects and take on the complexity of data storage for high volumes of samples. This has created a need for low-cost laboratory information management systems (LIMS) that contain flexible fields to accommodate the unique nature of individual labs. Many labs do not have a dedicated information technology position, so LIMS must also be easy to setup and maintain with minimal technical proficiency. Findings: MetaLIMS is a free and open-source web-based application available via GitHub. The focus of MetaLIMS is to store sample metadata prior to sequencing and analysis pipelines. Initially designed for environmental metagenomics labs, in addition to storing generic sample collection information and DNA/RNA processing information, the user can also add fields specific to the user's lab. MetaLIMS can also produce a basic sequencing submission form compatible with the proprietary Clarity LIMS system used by some sequencing facilities. To help ease the technical burden associated with web deployment, MetaLIMS options the use of commercial web hosting combined with MetaLIMS bash scripts for ease of setup. Conclusions: MetaLIMS overcomes key challenges common in LIMS by giving labs access to a low-cost and open-source tool that also has the flexibility to meet individual lab needs and an option for easy deployment. By making the web application open source and hosting it on GitHub, we hope to encourage the community to build upon MetaLIMS, making it more robust and tailored to the needs of more researchers. PMID:28430964
Spectral CT of the extremities with a silicon strip photon counting detector
NASA Astrophysics Data System (ADS)
Sisniega, A.; Zbijewski, W.; Stayman, J. W.; Xu, J.; Taguchi, K.; Siewerdsen, J. H.
2015-03-01
Purpose: Photon counting x-ray detectors (PCXDs) are an important emerging technology for spectral imaging and material differentiation with numerous potential applications in diagnostic imaging. We report development of a Si-strip PCXD system originally developed for mammography with potential application to spectral CT of musculoskeletal extremities, including challenges associated with sparse sampling, spectral calibration, and optimization for higher energy x-ray beams. Methods: A bench-top CT system was developed incorporating a Si-strip PCXD, fixed anode x-ray source, and rotational and translational motions to execute complex acquisition trajectories. Trajectories involving rotation and translation combined with iterative reconstruction were investigated, including single and multiple axial scans and longitudinal helical scans. The system was calibrated to provide accurate spectral separation in dual-energy three-material decomposition of soft-tissue, bone, and iodine. Image quality and decomposition accuracy were assessed in experiments using a phantom with pairs of bone and iodine inserts (3, 5, 15 and 20 mm) and an anthropomorphic wrist. Results: The designed trajectories improved the sampling distribution from 56% minimum sampling of voxels to 75%. Use of iterative reconstruction (viz., penalized likelihood with edge preserving regularization) in combination with such trajectories resulted in a very low level of artifacts in images of the wrist. For large bone or iodine inserts (>5 mm diameter), the error in the estimated material concentration was <16% for (50 mg/mL) bone and <8% for (5 mg/mL) iodine with strong regularization. For smaller inserts, errors of 20-40% were observed and motivate improved methods for spectral calibration and optimization of the edge-preserving regularizer. Conclusion: Use of PCXDs for three-material decomposition in joint imaging proved feasible through a combination of rotation-translation acquisition trajectories and iterative reconstruction with optimized regularization.
Alshamsan, Riyadh; Lee, John Tayu; Rana, Sangeeta; Areabi, Hasan; Millett, Christopher
2017-09-01
Objective To assess and compare health system performance across six middle-income countries that are strengthening their health systems in pursuit of universal health coverage. Design Cross-sectional analysis from the World Health Organization Study on global AGEing and adult health, collected between 2007 and 2010. Setting Six middle-income countries: China, Ghana, India, Mexico, Russia and South Africa. Participants Nationally representative sample of adults aged 50 years and older. Main outcome measures We present achievement against key indicators of health system performance across effectiveness, cost, access, patient-centredness and equity domains. Results We found areas of poor performance in prevention and management of chronic conditions, such as hypertension control and cancer screening coverage. We also found that cost remains a barrier to healthcare access in spite of insurance schemes. Finally, we found evidence of disparities across many indicators, particularly in the effectiveness and patient centredness domains. Conclusions These findings identify important focus areas for action and shared learning as these countries move towards achieving universal health coverage.
Airport cleanup rises above problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pressly, N.; Lucas, B.; Frumer, B.
Engineers used a treatment combination to improve the in-situ bioremediation system`s efficiency in removing underground fuel leaks at JFK Airport. John F. Kennedy International Airport, in New York City, on Jamaica Bay, has an above-ground storage capacity of about 32 million gallons of jet fuel, which flow through about 50 miles of high-pressure underground pipe to the central terminal area. EAch terminal`s fuel hydrant system was the major source os subsurface contamination at the site. The site is covered by 1 to 1.5 feet of reinforced concrete pavement. Liquid phase jet fuel (free product) was measured on the water tablemore » with true thickness ranging from less than 1 inch to 1 foot. After analysis of core samples, contamination was found adsorbed to the soil with maximum levels at the water table. This article describes the clean up, covering the following topics: microbial conditions during system operation; above-ground treatment challenges: free product emulsification, presence of biomass; evaluation of enhancements: dissolved air floatation, coagulation and flocculation, retention time adjustments; conclusions.« less
Social Work’s Role in Medicaid Reform: A Qualitative Study
Wachman, Madeline; Manning, Leticia; Cohen, Alexander M.; Seifert, Robert W.; Jones, David K.; Fitzgerald, Therese; Nuzum, Rachel; Riley, Patricia
2017-01-01
Objectives. To critically analyze social work’s role in Medicaid reform. Methods. We conducted semistructured interviews with 46 stakeholders from 10 US states that use a range of Medicaid reform approaches. We identified participants using snowball and purposive sampling. We gathered data in 2016 and analyzed them using qualitative methods. Results. Multiple themes emerged: (1) social work participates in Medicaid reform through clinical practice, including care coordination and case management; (2) there is a gap between social work’s practice-level and systems-level involvement in Medicaid innovations; (3) factors hindering social work’s involvement in systems-level practice include lack of visibility, insufficient clarity on social work’s role and impact, and too few resources within professional organizations; and (4) social workers need more training in health transformation payment models and policy. Conclusions. Social workers have unique skills that are valuable to building health systems that promote population health and reduce health inequities. Although there is considerable opportunity for social work to increase its role in Medicaid reform, there is little social work involvement at the systems level. PMID:29236537
Drewes, A M; Nielsen, K D; Taagholt, S J; Svendsen, L; Bjerregård, K; Nielsson, L; Kristensen, L
1996-05-01
A new system for polysomnographic recording at home is presented. It consists of a 12 to 24-channel amplifier system with direct digitization of the polygraph signals using a portable computer. Sampling frequency, amplification and filter settings can be defined by the user, and the signals are evaluated at bedside. Technical testing proved a high signal/noise ratio, linear amplification and a good signal quality. Clinical testing of the first 100 recordings showed that they were acceptable for conventional sleep scoring in 98 cases. A comparison of two consecutive recordings was done in 9 healthy subjects and 11 patients with rheumatic disorders. Using conventional sleep staging, only a slight "first night effect" (FNE) was demonstrated in the sleep architecture. Power spectral analysis using autoregressive modeling demonstrated only a difference of power between the 2 nights in the beta (14.5-25 Hz) band. In conclusion, the usability and technical advantages make the system very suitable for ambulatory recordings and only a minimal FNE should be considered when results are evaluated.
Alshamsan, Riyadh; Lee, John Tayu; Rana, Sangeeta; Areabi, Hasan; Millett, Christopher
2017-01-01
Objective To assess and compare health system performance across six middle-income countries that are strengthening their health systems in pursuit of universal health coverage. Design Cross-sectional analysis from the World Health Organization Study on global AGEing and adult health, collected between 2007 and 2010. Setting Six middle-income countries: China, Ghana, India, Mexico, Russia and South Africa. Participants Nationally representative sample of adults aged 50 years and older. Main outcome measures We present achievement against key indicators of health system performance across effectiveness, cost, access, patient-centredness and equity domains. Results We found areas of poor performance in prevention and management of chronic conditions, such as hypertension control and cancer screening coverage. We also found that cost remains a barrier to healthcare access in spite of insurance schemes. Finally, we found evidence of disparities across many indicators, particularly in the effectiveness and patient centredness domains. Conclusions These findings identify important focus areas for action and shared learning as these countries move towards achieving universal health coverage. PMID:28895493
Fowler, Katherine A.; Niolon, Phyllis H.
2014-01-01
Objectives. We estimated the frequency and examined the characteristics of intimate partner homicide and related deaths in 16 US states participating in the National Violent Death Reporting System (NVDRS), a state-based surveillance system. Methods. We used a combination of quantitative and qualitative methods to analyze NVDRS data from 2003 to 2009. We selected deaths linked to intimate partner violence for analysis. Results. Our sample comprised 4470 persons who died in the course of 3350 intimate partner violence–related homicide incidents. Intimate partners and corollary victims represented 80% and 20% of homicide victims, respectively. Corollary homicide victims included family members, new intimate partners, friends, acquaintances, police officers, and strangers. Conclusions. Our findings, from the first multiple-state study of intimate partner homicide and corollary homicides, demonstrate that the burden of intimate partner violence extends beyond the couple involved. Systems (e.g., criminal justice, medical care, and shelters) whose representatives routinely interact with victims of intimate partner violence can help assess the potential for lethal danger, which may prevent intimate partner and corollary victims from harm. PMID:24432943
RAKHSHANPOUR, Arash; MOHEBALI, Mehdi; AKHONDI, Behnaz; RAHIMI, Mohammad Taghi; ROKNI, Mohammad Bagher
2014-01-01
Abstract Background Visceral leishmaniasis (VL) or kala-azar is considered as a parasitic disease caused by the species of Leishmania donovani complex which is intracellular parasites. This systemic disease is endemic in some parts of provinc-es of Iran. The aim of this study was to determine the seroprevalence of VL in Qom Province, central Iran using di-rect agglutination test (DAT). Methods Overall, 1564 serum samples (800 males and 764 females) were collected from selected subjects by random-ized cluster sampling in 2011-2012. Sera were tested and analyzed by DAT. Before sampling; a questionnaire was filled out for each case. Data were analyzed using Chi-square test and multivariate logistic regression for risk factors analysis. Results Of 1564 individuals, 53 cases (3.38%) showed Leishmania specific antibodies as follows: with 1:400 titer 16 cases (1.02%), with 1:800 titer 20 cases (1.27%), with 1:1600 titer 16 cases (1.02%) whereas only one subject (0.06%) showed titers of ≥ 1:3200. There was no significant association between VL seropositivity and gender, age group and occupation. Binary logistic regression showed that rural areas was 0.44 times at higher risk of infection than urban areas (OR= 0.44; %95 CI= 0.25- 0.78). Conclusion Although the seroprevalence of VL is relatively low in Qom Province, yet due to the importance of the disease, the surveillance system should be monitored by health authorities. PMID:26060679
Marlowe, Elizabeth M; Hardy, David; Krevolin, Mark; Gohl, Peter; Bertram, Alexander; Arcenas, Rodney; Seiverth, Britta; Schneider, Tanja; Liesenfeld, Oliver
2017-09-01
We compared the analytical and clinical performance of cobas ® CT/NG for use on the Cobas ® 6800/8800 Systems with the Cobas ® 4800 CT/NG Test from urogenital and extragenital specimens in over 12,000 specimens from both male and female subjects in Germany and the United States. The analytical sensitivity was ≤40 EB/ml for Chlamydia trachomatis (CT) and ≤1 CFU/ml for Neisseria gonorrhoeae (NG). Using clinical specimens, the overall percent agreement with the Cobas ® 4800 CT/NG Test was >98.5%. Across urogenital specimens, there were 93 discrepant specimens; 76 (93.8%) of 81 CT discrepant specimens were 6800+/4800- and 10 (83.3%) of 12 NG discrepant specimens were 6800+/4800-. Sequencing verified CT results for 45 (61.6%) of 73 samples positive by 6800 and 1 (20%) of 5 positive by 4800. Similarly, 7 (70.0%) of 10 NG samples positive by 6800 and 1 of 2 positive by 4800 were confirmed by sequencing. Among discrepant extragenital specimens (all 6800+/4800-), 7 (50%) of 14 oropharyngeal and 23 (76.7%) of 30 anorectal CT discordant samples were confirmed as CT positive by sequencing; all 8 anorectal and 20 (90.9%) of 22 oropharyngeal NG discordant results were also confirmed as NG positive. In conclusion, Cobas ® CT/NG for use on the Cobas ® 6800/8800 Systems provides high-throughput automated solutions for sexually transmitted infection (STI) screening programs.
Cocci, Andrea; Zuppi, Cecilia; Persichilli, Silvia
2013-01-01
Objective. 25-hydroxyvitamin D2/D3 (25-OHD2/D3) determination is a reliable biomarker for vitamin D status. Liquid chromatography-tandem mass spectrometry was recently proposed as a reference method for vitamin D status evaluation. The aim of this work is to compare two commercial kits (Chromsystems and PerkinElmer) for 25-OHD2/D3 determination by our entry level LC-MS/MS. Design and Methods. Chromsystems kit adds an online trap column to an HPLC column and provides atmospheric pressure chemical ionization, isotopically labeled internal standard, and 4 calibrator points. PerkinElmer kit uses a solvent extraction and protein precipitation method. This kit can be used with or without derivatization with, respectively, electrospray and atmospheric pressure chemical ionization. For each analyte, there are isotopically labeled internal standards and 7 deuterated calibrator points. Results. Performance characteristics are acceptable for both methods. Mean bias between methods calculated on 70 samples was 1.9 ng/mL. Linear regression analysis gave an R 2 of 0.94. 25-OHD2 is detectable only with PerkinElmer kit in derivatized assay option. Conclusion. Both methods are suitable for routine. Chromsystems kit minimizes manual sample preparation, requiring only protein precipitation, but, with our system, 25-OHD2 is not detectable. PerkinElmer kit without derivatization does not guarantee acceptable performance with our LC-MS/MS system, as sample is not purified online. Derivatization provides sufficient sensitivity for 25-OHD2 detection. PMID:23555079
Gani, Dhruva Kumar; Lakshmi, Deepa; Krishnan, Rama; Emmadi, Pamela
2009-01-01
Aims and Objectives: The aim of the present study was to investigate systemic levels of inflammatory markers of cardiovascular diseases like C-reactive protein and interleukin-6 in patients with chronic periodontitis, in comparison to periodontally healthy individuals. Materials and Methods: A total of 42 individuals, both males and females above the age of 30 years, were included in the study. Healthy controls (Group I, n = 14), chronic localized periodontitis (Group II, n = 14), and chronic generalized periodontitis (Group III, n = 14), all without any medical disorder, were recruited. Peripheral blood samples were taken and C-reactive protein (CRP) levels were estimated in the serum samples by using the Particle-Enhanced Turbidimetric Immunoassay (PETIA) technique. Serum samples of Interleukin-6 (IL-6) were assayed by using the Chemiluminescent Immunoassay (IMMULITE) technique. Results: When mean CRP levels were compared between the groups, group III showed statistical significance when compared to group I (P = 0.04). Group III had a higher median IL-6 level (6.35 pg/mL) than Group II (< 5.0 pg/mL) and group I (< 5.0 pg/mL). Differences in median values of IL-6 were not statistically significant in any group (P = 0.29). Conclusion: Periodontitis results in higher systemic levels of CRP and IL-6. These elevated inflammatory factors may increase inflammatory activity in atherosclerotic lesions and potentially increasing the risk for cardiovascular events. PMID:20407653
Improving Ambulatory Saliva-Sampling Compliance in Pregnant Women: A Randomized Controlled Study
Moeller, Julian; Lieb, Roselind; Meyer, Andrea H.; Loetscher, Katharina Quack; Krastel, Bettina; Meinlschmidt, Gunther
2014-01-01
Objective Noncompliance with scheduled ambulatory saliva sampling is common and has been associated with biased cortisol estimates in nonpregnant subjects. This study is the first to investigate in pregnant women strategies to improve ambulatory saliva-sampling compliance, and the association between sampling noncompliance and saliva cortisol estimates. Methods We instructed 64 pregnant women to collect eight scheduled saliva samples on two consecutive days each. Objective compliance with scheduled sampling times was assessed with a Medication Event Monitoring System and self-reported compliance with a paper-and-pencil diary. In a randomized controlled study, we estimated whether a disclosure intervention (informing women about objective compliance monitoring) and a reminder intervention (use of acoustical reminders) improved compliance. A mixed model analysis was used to estimate associations between women's objective compliance and their diurnal cortisol profiles, and between deviation from scheduled sampling and the cortisol concentration measured in the related sample. Results Self-reported compliance with a saliva-sampling protocol was 91%, and objective compliance was 70%. The disclosure intervention was associated with improved objective compliance (informed: 81%, noninformed: 60%), F(1,60) = 17.64, p<0.001, but not the reminder intervention (reminders: 68%, without reminders: 72%), F(1,60) = 0.78, p = 0.379. Furthermore, a woman's increased objective compliance was associated with a higher diurnal cortisol profile, F(2,64) = 8.22, p<0.001. Altered cortisol levels were observed in less objective compliant samples, F(1,705) = 7.38, p = 0.007, with delayed sampling associated with lower cortisol levels. Conclusions The results suggest that in pregnant women, objective noncompliance with scheduled ambulatory saliva sampling is common and is associated with biased cortisol estimates. To improve sampling compliance, results suggest informing women about objective compliance monitoring but discourage use of acoustical reminders. PMID:24465958
Almutairy, Meznah; Torng, Eric
2018-01-01
Bioinformatics applications and pipelines increasingly use k-mer indexes to search for similar sequences. The major problem with k-mer indexes is that they require lots of memory. Sampling is often used to reduce index size and query time. Most applications use one of two major types of sampling: fixed sampling and minimizer sampling. It is well known that fixed sampling will produce a smaller index, typically by roughly a factor of two, whereas it is generally assumed that minimizer sampling will produce faster query times since query k-mers can also be sampled. However, no direct comparison of fixed and minimizer sampling has been performed to verify these assumptions. We systematically compare fixed and minimizer sampling using the human genome as our database. We use the resulting k-mer indexes for fixed sampling and minimizer sampling to find all maximal exact matches between our database, the human genome, and three separate query sets, the mouse genome, the chimp genome, and an NGS data set. We reach the following conclusions. First, using larger k-mers reduces query time for both fixed sampling and minimizer sampling at a cost of requiring more space. If we use the same k-mer size for both methods, fixed sampling requires typically half as much space whereas minimizer sampling processes queries only slightly faster. If we are allowed to use any k-mer size for each method, then we can choose a k-mer size such that fixed sampling both uses less space and processes queries faster than minimizer sampling. The reason is that although minimizer sampling is able to sample query k-mers, the number of shared k-mer occurrences that must be processed is much larger for minimizer sampling than fixed sampling. In conclusion, we argue that for any application where each shared k-mer occurrence must be processed, fixed sampling is the right sampling method.
Torng, Eric
2018-01-01
Bioinformatics applications and pipelines increasingly use k-mer indexes to search for similar sequences. The major problem with k-mer indexes is that they require lots of memory. Sampling is often used to reduce index size and query time. Most applications use one of two major types of sampling: fixed sampling and minimizer sampling. It is well known that fixed sampling will produce a smaller index, typically by roughly a factor of two, whereas it is generally assumed that minimizer sampling will produce faster query times since query k-mers can also be sampled. However, no direct comparison of fixed and minimizer sampling has been performed to verify these assumptions. We systematically compare fixed and minimizer sampling using the human genome as our database. We use the resulting k-mer indexes for fixed sampling and minimizer sampling to find all maximal exact matches between our database, the human genome, and three separate query sets, the mouse genome, the chimp genome, and an NGS data set. We reach the following conclusions. First, using larger k-mers reduces query time for both fixed sampling and minimizer sampling at a cost of requiring more space. If we use the same k-mer size for both methods, fixed sampling requires typically half as much space whereas minimizer sampling processes queries only slightly faster. If we are allowed to use any k-mer size for each method, then we can choose a k-mer size such that fixed sampling both uses less space and processes queries faster than minimizer sampling. The reason is that although minimizer sampling is able to sample query k-mers, the number of shared k-mer occurrences that must be processed is much larger for minimizer sampling than fixed sampling. In conclusion, we argue that for any application where each shared k-mer occurrence must be processed, fixed sampling is the right sampling method. PMID:29389989
ERIC Educational Resources Information Center
Santos, Antonio J.; Peceguina, Ines; Daniel, Joao R.; Shin, Nana; Vaughn, Brian E.
2013-01-01
This study tested assumptions and conclusions reached in an earlier confirmatory factor analysis (CFA) study of the social competence (SC) construct for preschool children. Two samples (total N = 408; a new Portuguese sample and one from US samples that had participated in the original study) contributed data. Seven SC indicators were tested for…
Perioperative Corticosteroids Reduce Short-Term Edema and Ecchymosis in Rhinoplasty: A Meta-Analysis
Coroneos, Christopher J; Voineskos, Sophocles H; Cook, Deborah J; Farrokhyar, Forough; Thoma, Achilleas
2016-01-01
Abstract Background A number of randomized controlled trials (RCTs) have investigated the role of perioperative corticosteroids in rhinoplasty. Each of these trials however has an insufficient sample sizes to reach definitive conclusions and detect harms. Three recent reviews have analyzed edema and ecchymosis outcomes following rhinoplasty; each arrived at a different conclusion and recommendation. Objective To estimate the effectiveness of systemic perioperative corticosteroid treatment compared to placebo for clinical outcomes in rhinoplasty using a methodologically rigorous meta-analysis. Methods Electronic databases were searched without language restriction. Included trials were randomized controlled trials of systemic perioperative corticosteroid treatment vs placebo in rhinoplasty evaluating at least one of: edema, ecchymosis, bleeding, cosmetic outcome, and patient satisfaction. The Cochrane risk of bias tool was applied to included trials, and the quality of evidence for each outcome was assessed using the GRADE approach. Results Analyses included 336 patients from eight trials. Perioperative corticosteroids reduced the worst edema (SMD: −1.03, 95%CI −1.30 to −0.76, P < .001) and ecchymosis (SMD: −0.78, 95%CI −1.09 to 0.47, P < .001) after rhinoplasty. At one day postoperative, a single dose of perioperative corticosteroid reduced edema (SMD −1.15, 95%CI −1.42 to −0.87, P < .001) and ecchymosis (SMD −0.79, 95%CI −1.05 to −0.52, P < .001). No clinical benefit in edema or ecchymosis was found seven days postoperatively, nor did intraoperative bleeding increase. Conclusions There is high quality evidence to support perioperative systemic corticosteroid treatment in rhinoplasty to reduce short-term edema and ecchymosis without increased intraoperative bleeding. These findings are not present at seven days. For future trials, we suggest evaluation of patient satisfaction, and correlation with long-term cosmetic outcome. Level of Evidence: 2 PMID:26773090
NASA Astrophysics Data System (ADS)
Ganesh, Shruthi Vatsyayani
With the advent of microfluidic technologies for molecular diagnostics, a lot of emphasis has been placed on developing diagnostic tools for resource poor regions in the form of Extreme Point of Care devices. To ensure commercial viability of such a device there is a need to develop an accurate sample to answer system, which is robust, portable, isolated yet highly sensitive and cost effective. This need has been a driving force for research involving integration of different microsystems like droplet microfluidics, Compact-disc (CD)microfluidics along with sample preparation and detection modules on a single platform. This work attempts to develop a proof of concept prototype of one such device using existing CD microfluidics tools to generate stable droplets used in point of care diagnostics (POC diagnostics). Apart from using a fairly newer technique for droplet generation and stabilization, the work aims to develop this method focused towards diagnostics for rural healthcare. The motivation for this work is first described with an emphasis on the current need for diagnostic testing in rural health-care and the general guidelines prescribed by WHO for such a sample to answer system. Furthermore, a background on CD and droplet microfluidics is presented to understand the merits and de-merits of each system and the need for integrating the two. This phase of the thesis also includes different methods employed/demonstrated to generate droplets on a spinning platform. An overview on the detection platforms is also presented to understand the challenges involved in building an extreme point of care device. In the third phase of the thesis, general manufacturing techniques and materials used to accomplish this work is presented. Lastly, design trials for droplet generation is presented. The shortcomings of these trials are solved by investigating mechanisms pertaining to design modification and use of agarose based droplet generation to ensure a more robust sample processing method. This method is further characterized and compared with non-agarose based system and the results are analyzed. In conclusion, future prospects of this work are discussed in relation to extreme POC applications.
Rahman, Mokhlasur; Huys, Geert; Rahman, Motiur; Albert, M. John; Kühn, Inger; Möllby, Roland
2007-01-01
The persistence and transmission of Aeromonas in a duckweed aquaculture-based hospital sewage water treatment plant in Bangladesh was studied. A total of 670 samples from different sites of the hospital sewage water treatment plant, from feces of hospitalized children suffering from diarrhea, from environmental control ponds, and from feces of healthy humans were collected over a period of three years. In total, 1,315 presumptive Aeromonas isolates were biochemically typed by the PhenePlate rapid screening system (PhP-AE). A selection of 90 representative isolates was further analyzed with PhenePlate (PhP) extended typing (PhP-48), fatty acid methyl ester analysis, and amplified fragment length polymorphism (AFLP) fingerprinting. In addition, the prevalence of the putative virulence factors hemolysin and cytotoxin and the presence of the cytolytic enterotoxin gene (AHCYTOEN) were analyzed. Aeromonas was found at all sites of the treatment plant, in 40% of the samples from environmental control ponds, in 8.5% of the samples from hospitalized children suffering from diarrhea, and in 3.5% of samples from healthy humans. A significantly high number of Aeromonas bacteria was found in duckweed, which indicates that duckweed may serve as a reservoir for these bacteria. PhP-AE typing allowed identification of more than 192 distinct PhP types, of which 18 major PhP types (MTs) were found in multiple sites and during several occasions. AFLP fingerprinting revealed the prevalence of genotypically indistinguishable Aeromonas isolates among certain PhP MTs recovered from different sampling occasions and/or at multiple sites. Hemolytic and cytotoxic activities were observed in 43% of the tested strains, whereas 29% possessed the cytolytic enterotoxin gene AHCYTOEN. Collectively, two specific MTs associated with diarrhea were shown to exhibit high cytotoxicity. Furthermore, all tested isolates of these major types were positive for the cytolytic enterotoxin gene. In conclusion, our data indicate that certain phenotypically and genotypically stable clonal lineages of Aeromonas have persisted in the treatment system for a prolonged period and might spread from the hospitalized children suffering from diarrhea to fish produced for human consumption through the sewage water treatment system. PMID:17194839
Multi-user investigation organizer
NASA Technical Reports Server (NTRS)
Panontin, Tina L. (Inventor); Williams, James F. (Inventor); Carvalho, Robert E. (Inventor); Sturken, Ian (Inventor); Wolfe, Shawn R. (Inventor); Gawdiak, Yuri O. (Inventor); Keller, Richard M. (Inventor)
2009-01-01
A system that allows a team of geographically dispersed users to collaboratively analyze a mishap event. The system includes a reconfigurable ontology, including instances that are related to and characterize the mishap, a semantic network that receives, indexes and stores, for retrieval, viewing and editing, the instances and links between the instances, a network browser interface for retrieving and viewing screens that present the instances and links to other instances and that allow editing thereof, and a rule-based inference engine, including a collection of rules associated with establishment of links between the instances. A possible conclusion arising from analysis of the mishap event may be characterized as one or more of: not a credible conclusion; an unlikely conclusion; a credible conclusion; conclusion needs analysis; conclusion needs supporting data; conclusion proposed to be closed; and an un-reviewed conclusion.
Integration of the Super Nova early warning system with the NOvA Trigger
DOE Office of Scientific and Technical Information (OSTI.GOV)
Habig, Alec; Zirnstein, Jan
The NOvA experiment, with a baseline of 810km, samples Fermilab’s upgraded NuMI beam with a Near Detector on-site and a Far Detector (FD) at Ash River, MN, to observe oscillations of muon neutrinos. The 344,064 liquid scintillator-filled cells of the 14 kton FD provide high granularity of a large detector mass and enable us to also study non-accelerator based neutrinos with our Data Driven Trigger framework. This paper will focus on the real time integration of the SNEWS with the NOvA Trigger where we have set up an XML-RPC based messaging system to inject the SNEWS signal directly into ourmore » trigger. In conclusion, this presents a departure from the E-Mail based notification mechanism used by SNEWS in the past and allows NOvA more control over propagation and transmission timing.« less
Integration of the Super Nova early warning system with the NOvA Trigger
Habig, Alec; Zirnstein, Jan
2015-12-23
The NOvA experiment, with a baseline of 810km, samples Fermilab’s upgraded NuMI beam with a Near Detector on-site and a Far Detector (FD) at Ash River, MN, to observe oscillations of muon neutrinos. The 344,064 liquid scintillator-filled cells of the 14 kton FD provide high granularity of a large detector mass and enable us to also study non-accelerator based neutrinos with our Data Driven Trigger framework. This paper will focus on the real time integration of the SNEWS with the NOvA Trigger where we have set up an XML-RPC based messaging system to inject the SNEWS signal directly into ourmore » trigger. In conclusion, this presents a departure from the E-Mail based notification mechanism used by SNEWS in the past and allows NOvA more control over propagation and transmission timing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nabeel A. Riza
The goals of the first six months of this project were to lay the foundations for both the SiC front-end optical chip fabrication as well as the free-space laser beam interferometer designs and preliminary tests. In addition, a Phase I goal was to design and experimentally build the high temperature and pressure infrastructure and test systems that will be used in the next 6 months for proposed sensor experimentation and data processing. All these goals have been achieved and are described in detail in the report. Both design process and diagrams for the mechanical elements as well as the opticalmore » systems are provided. In addition, photographs of the fabricated SiC optical chips, the high temperature & pressure test chamber instrument, the optical interferometer, the SiC sample chip holder, and signal processing data are provided. The design and experimentation results are summarized to give positive conclusions on the proposed novel high temperature optical sensor technology.« less
Application of a systemic approach to the study of pollution of the Tinto and Odiel rivers (Spain).
Sainz, A; Grande, J A; De La Torre, M L
2005-03-01
The province of Huelva in the SW of Spain presents high environmental contrasts: together with the great abundance of natural spaces, it shows the impacts of historical natural resources exploitation processes. In the Ria of Huelva, the effluents of the chemical industries must be added to the contaminating inputs of the Tinto and Odiel rivers, coming from the acid drainage of the mines located in the Iberian Pyrite Belt. This forced the Environmental Agency (AMA) to elaborate in 1987 an Effluent Remediation Plan in order to negate unacceptable environmental impacts. The application of a "grey box" systemic analysis to the AMD pollution, undergone by the Tinto and Odiel rivers has allowed to set a conclusive explanation of the sampling results observed for a period of 11 years, thus making available an overall view of the polluting process and, above all, an explanation of its partial aspects.
Wang, Jun; Hwang, Kiwook; Braas, Daniel; Dooraghi, Alex; Nathanson, David; Campbell, Dean O.; Gu, Yuchao; Sandberg, Troy; Mischel, Paul; Radu, Caius; Chatziioannou, Arion F.; Phelps, Michael E.; Christofk, Heather; Heath, James R.
2014-01-01
We report on a radiopharmaceutical imaging platform designed to capture the kinetics of cellular responses to drugs. Methods A portable in vitro molecular imaging system, comprised of a microchip and a beta-particle imaging camera, permits routine cell-based radioassays on small number of either suspension or adherent cells. We investigate the response kinetics of model lymphoma and glioblastoma cancer cell lines to [18F]fluorodeoxyglucose ([18F]FDG) uptake following drug exposure. Those responses are correlated with kinetic changes in the cell cycle, or with changes in receptor-tyrosine kinase signaling. Results The platform enables radioassays directly on multiple cell types, and yields results comparable to conventional approaches, but uses smaller sample sizes, permits a higher level of quantitation, and doesn’t require cell lysis. Conclusion The kinetic analysis enabled by the platform provides a rapid (~1 hour) drug screening assay. PMID:23978446
Sridhar, M K; Carter, R; Moran, F; Banham, S W
1993-01-01
BACKGROUND--Accurate and reliable measurement of gas exchange during exercise has traditionally involved arterial cannulation. Non-invasive devices to estimate arterial oxygen (O2) and carbon dioxide (CO2) tensions are now available. A method has been devised and evaluated for measuring gas exchange during exercise with a combined transcutaneous O2 and CO2 electrode. METHODS--Symptom limited exercise tests were carried out in 24 patients reporting effort intolerance and breathlessness. Exercise testing was performed by bicycle ergometry with a specifically designed protocol involving gradual two minute workload increments. Arterial O2 and CO2 tensions were measured at rest and during exercise by direct blood sampling from an indwelling arterial cannula and a combined transcutaneous electrode heated to 45 degrees C. The transcutaneous system was calibrated against values obtained by direct arterial sampling before each test. RESULTS--In all tests the trend of gas exchange measured by the transcutaneous system was true to the trend measured from direct arterial sampling. In the 140 measurements the mean difference between the O2 tensions estimated by direct sampling and the transcutaneous method was 0.08 kPa (0.62 mm Hg, limits of agreement 4.42 and -3.38 mm Hg). The mean difference between the methods for CO2 was 0.02 kPa (0.22 mm Hg, limits of agreement 2.20 and -1.70 mm Hg). There was no morbidity associated with the use of the transcutaneous electrode heated to 45 degrees C. CONCLUSIONS--A combined transcutaneous O2 and CO2 electrode heated to 45 degrees C can be used to provide a reliable estimate of gas exchange during gradual incremental exercise in adults. PMID:8346496
Real-time Automated Sampling of Electronic Medical Records Predicts Hospital Mortality
Khurana, Hargobind S.; Groves, Robert H.; Simons, Michael P.; Martin, Mary; Stoffer, Brenda; Kou, Sherri; Gerkin, Richard; Reiman, Eric; Parthasarathy, Sairam
2016-01-01
Background Real-time automated continuous sampling of electronic medical record data may expeditiously identify patients at risk for death and enable prompt life-saving interventions. We hypothesized that a real-time electronic medical record-based alert could identify hospitalized patients at risk for mortality. Methods An automated alert was developed and implemented to continuously sample electronic medical record data and trigger when at least two of four systemic inflammatory response syndrome criteria plus at least one of 14 acute organ dysfunction parameters was detected. The SIRS/OD alert was applied real-time to 312,214 patients in 24 hospitals and analyzed in two phases: training and validation datasets. Results In the training phase, 29,317 (18.8%) triggered the alert and 5.2% of such patients died whereas only 0.2% without the alert died (unadjusted odds ratio 30.1; 95% confidence interval [95%CI] 26.1, 34.5; P<0.0001). In the validation phase, the sensitivity, specificity, area under curve (AUC), positive and negative likelihood ratios for predicting mortality were 0.86, 0.82, 0.84, 4.9, and 0.16, respectively. Multivariate Cox-proportional hazard regression model revealed greater hospital mortality when the alert was triggered (adjusted Hazards Ratio 4.0; 95%CI 3.3, 4.9; P<0.0001). Triggering the alert was associated with additional hospitalization days (+3.0 days) and ventilator days (+1.6 days; P<0.0001). Conclusion An automated alert system that continuously samples electronic medical record-data can be implemented, has excellent test characteristics, and can assist in the real-time identification of hospitalized patients at risk for death. PMID:27019043
Suzuki, Kenichiro; Komukai, Kimiaki; Nakata, Kotaro; Kan, Renshi; Oi, Yuhei; Muto, Eri; Kashiwagi, Yusuke; Tominaga, Mitsutoshi; Miyanaga, Satoru; Ishikawa, Tetsuya; Okuno, Kenji; Uzura, Masahiko; Yoshimura, Michihiro
2018-02-09
Objective This study was carried out to examine the usefulness of point-of-care (POC) cardiac troponin in diagnosing acute coronary syndrome (ACS) and to understand the limitations of a POC cardiac troponin I/T-based diagnoses. Methods Patients whose cardiac troponin levels were measured in the emergency department using a POC system (AQT System; Radiometer, Tokyo, Japan) between January and December 2016 were retrospectively examined (N=1449). Patients who were < 20 years of age or who were admitted with cardiopulmonary arrest were excluded. The sensitivity and specificity of the POC cardiac troponin levels for the diagnosis of ACS were determined. Result One hundred and twenty of 1449 total patients had ACS (acute myocardial infarction, n=88; unstable angina n=32). On comparing the receiver operating characteristic (ROC) curves, the area under the curve (AUC) values for POC cardiac troponin I and cardiac troponin T were 0.833 and 0.786, respectively. The sensitivity and specificity of POC cardiac troponin I when using the 99th percentile (0.023 ng/mL) as the diagnostic cut-off value were 69.0% and 88.1%, respectively. The sensitivity of POC cardiac troponin I (99th percentile) was higher in the patients sampled > 3 h after symptom onset (83.3%) than in those sampled ≤ 3 h after symptom onset (58.8%, p < 0.01). Conclusion When sampled > 3 h after the onset of symptoms, the POC cardiac troponin I level is considered to be suitable for use in diagnosing ACS. However, when sampled ≤ 3 h after the onset of symptoms, careful interpretation of POC cardiac troponins is therefore required to rule out ACS.
Mackey, Sean
2016-01-01
Background We describe here Survalytics, a software module designed to address two broad areas of need. The first area is in the domain of surveys and app analytics: developers of mobile apps in both academic and commercial environments require information about their users, as well as how the apps are being used, to understand who their users are and how to optimally approach app development. The second area of need is in the field of ecological momentary assessment, also referred to as experience sampling: researchers in a wide variety of fields, spanning from the social sciences to psychology to clinical medicine, would like to be able to capture daily or even more frequent data from research subjects while in their natural environment. Objective Survalytics is an open-source solution for the collection of survey responses as well as arbitrary analytic metadata from users of Android operating system apps. Methods Surveys may be administered in any combination of one-time questions and ongoing questions. The module may be deployed as a stand-alone app for experience sampling purposes or as an add-on to existing apps. The module takes advantage of free-tier NoSQL cloud database management offered by the Amazon Web Services DynamoDB platform to package a secure, flexible, extensible data collection module. DynamoDB is capable of Health Insurance Portability and Accountability Act compliant storage of personal health information. Results The provided example app may be used without modification for a basic experience sampling project, and we provide example questions for daily collection of blood glucose data from study subjects. Conclusions The module will help researchers in a wide variety of fields rapidly develop tailor-made Android apps for a variety of data collection purposes. PMID:27261155
Medicines discarded in household garbage: analysis of a pharmaceutical waste sample in Vienna
2014-01-01
Objectives To analyze a sample of pharmaceutical waste drawn from household garbage in Vienna, with the aim to learn whether and which medicines end up unused in normal household waste. Methods We obtained a pharmaceutical waste sample from the Vienna Municipal Waste Department. This was drawn by their staff in a representative search in October and November 2009. We did a manual investigation of the sample which contained packs and loose blisters, excluded medical devices and traced loose blisters back to medicines packs. We reported information on the prescription status, origin, therapeutic group, dose form, contents and expiry date. We performed descriptive statistics for the total data set and for sub-groups (e.g. items still containing some of original content). Results In total, 152 packs were identified, of which the majority was prescription-only medicines (74%). Cardiovascular medicines accounted for the highest share (24%). 87% of the packs were in oral form. 95% of the packs had not expired. 14.5% of the total data set contained contents but the range of content left in the packs varied. Results on the packs with contents differed from the total: the shares of Over-the Counter medicines (36%), of medicines of the respiratory system (18%) and of the musculo-skeletal system (18%), for dermal use (23%) and of expired medicines (19%) were higher compared to the full data set. Conclusions The study showed that some medicines end up unused or partially used in normal household garbage in Vienna. Our results did not confirm speculations about a high percentage of unused medicines improperly discarded. There is room for improved patient information and counseling to enhance medication adherence and a proper discharge of medicines. PMID:25848546
Hernández Garfella, María Luisa; Palomares Fort, Paula; Román Ivorra, José Andrés; Cervera Taulet, Enrique
2015-01-01
Purpose: To assess changes in aqueous humor levels of different interleukins (IL), tumor necrosis factor (TNF)-α and vascular endothelial growth factor (VEGF) in patients with uveitis treated with adalimumab. Methods: In this study, 24 aqueous humor samples including 12 pre- and post-treatment samples from 6 patients with uveitis treated with subcutaneous adalimumab and 12 samples from patients with cataracts (serving as controls) were evaluated. The levels of IL-1β, IL-2, IL-6, IL-10, TNF-α and VEGF were measured using a Luminex® 200™ flow cytometer (Merckmillipore, Merck KGaA, Darmstadt, Alemania) and a highly sensitive ELISA system. Results: The levels of IL-1β, IL-2, IL-6 and IL-10 in the aqueous humor before and after treatment with adalimumab did not show significant differences. Aqueous VEGF levels significantly reduced after treatment with adalimumab (P = 0.028). Aqueous TNF-α levels did not significantly change after treatment with adalimumab, however the post-treatment level was significantly higher in patients as compared to control subjects (P = 0.032). IL-2 showed significantly higher levels in uveitis patients before treatment as compared to controls (P = 0.024), while its post-treatment levels were almost normalized. Conclusion: Decrease in the aqueous humor levels of VEGF and IL-2 after treatment with systemic adalimumab indicates that anti-TNF-α therapy induces modifications of some inflammatory mediators involved in the pathogenesis of uveitis. Aqueous humor samples may be useful to assess the effect of adalimumab on intraocular inflammation through measurement of cytokines. PMID:26005553
Yáñez, M Adela; Nocker, Andreas; Soria-Soria, Elena; Múrtula, Raquel; Martínez, Lorena; Catalán, Vicente
2011-05-01
One of the greatest challenges of implementing fast molecular detection methods as part of Legionella surveillance systems is to limit detection to live cells. In this work, a protocol for sample treatment with propidium monoazide (PMA) in combination with quantitative PCR (qPCR) has been optimized and validated for L. pneumophila as an alternative of the currently used time-consuming culture method. Results from PMA-qPCR were compared with culture isolation and traditional qPCR. Under the conditions used, sample treatment with 50 μM PMA followed by 5 min of light exposure were assumed optimal resulting in an average reduction of 4.45 log units of the qPCR signal from heat-killed cells. When applied to environmental samples (including water from cooling water towers, hospitals, spas, hot water systems in hotels, and tap water), different degrees of correlations between the three methods were obtained which might be explained by different matrix properties, but also varying degrees of non-culturable cells. It was furthermore shown that PMA displayed substantially lower cytotoxicity with Legionella than the alternative dye ethidium monoazide (EMA) when exposing live cells to the dye followed by plate counting. This result confirmed the findings with other species that PMA is less membrane-permeant and more selective for the intact cells. In conclusion, PMA-qPCR is a promising technique for limiting detection to intact cells and makes Legionella surveillance data substantially more relevant in comparison with qPCR alone. For future research it would be desirable to increase the method's capacity to exclude signals from dead cells in difficult matrices or samples containing high numbers of dead cells. Copyright © 2011 Elsevier B.V. All rights reserved.
Kwakkenbos, Linda; Arthurs, Erin; van den Hoogen, Frank H. J.; Hudson, Marie; van Lankveld, Wim G. J. M.; Baron, Murray; van den Ende, Cornelia H. M.; Thombs, Brett D.
2013-01-01
Objectives Increasingly, medical research involves patients who complete outcomes in different languages. This occurs in countries with more than one common language, such as Canada (French/English) or the United States (Spanish/English), as well as in international multi-centre collaborations, which are utilized frequently in rare diseases such as systemic sclerosis (SSc). In order to pool or compare outcomes, instruments should be measurement equivalent (invariant) across cultural or linguistic groups. This study provides an example of how to assess cross-language measurement equivalence by comparing the Center for Epidemiologic Studies Depression (CES-D) scale between English-speaking Canadian and Dutch SSc patients. Methods The CES-D was completed by 922 English-speaking Canadian and 213 Dutch SSc patients. Confirmatory factor analysis (CFA) was used to assess the factor structure in both samples. The Multiple-Indicator Multiple-Cause (MIMIC) model was utilized to assess the amount of differential item functioning (DIF). Results A two-factor model (positive and negative affect) showed excellent fit in both samples. Statistically significant, but small-magnitude, DIF was found for 3 of 20 items on the CES-D. The English-speaking Canadian sample endorsed more feeling-related symptoms, whereas the Dutch sample endorsed more somatic/retarded activity symptoms. The overall estimate in depression scores between English and Dutch was not influenced substantively by DIF. Conclusions CES-D scores from English-speaking Canadian and Dutch SSc patients can be compared and pooled without concern that measurement differences may substantively influence results. The importance of assessing cross-language measurement equivalence in rheumatology studies prior to pooling outcomes obtained in different languages should be emphasized. PMID:23326538
Rosenberg, Justin F; Haulena, Martin; Phillips, Brianne E; Harms, Craig A; Lewbart, Gregory A; Lahner, Lesanna L; Papich, Mark G
2016-11-01
OBJECTIVE To determine population pharmacokinetics of enrofloxacin in purple sea stars (Pisaster ochraceus) administered an intracoelomic injection of enrofloxacin (5 mg/kg) or immersed in an enrofloxacin solution (5 mg/L) for 6 hours. ANIMALS 28 sea stars of undetermined age and sex. PROCEDURES The study had 2 phases. Twelve sea stars received an intracoelomic injection of enrofloxacin (5 mg/kg) or were immersed in an enrofloxacin solution (5 mg/L) for 6 hours during the injection and immersion phases, respectively. Two untreated sea stars were housed with the treated animals following enrofloxacin administration during both phases. Water vascular system fluid samples were collected from 4 sea stars and all controls at predetermined times during and after enrofloxacin administration. The enrofloxacin concentration in those samples was determined by high-performance liquid chromatography. For each phase, noncompartmental analysis of naïve averaged pooled samples was used to obtain initial parameter estimates; then, population pharmacokinetic analysis was performed that accounted for the sparse sampling technique used. RESULTS Injection phase data were best fit with a 2-compartment model; elimination half-life, peak concentration, area under the curve, and volume of distribution were 42.8 hours, 18.9 μg/mL, 353.8 μg•h/mL, and 0.25 L/kg, respectively. Immersion phase data were best fit with a 1-compartment model; elimination half-life, peak concentration, and area under the curve were 56 hours, 36.3 μg•h/mL, and 0.39 μg/mL, respectively. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that the described enrofloxacin administration resulted in water vascular system fluid drug concentrations expected to exceed the minimum inhibitory concentration for many bacterial pathogens.
NASA Astrophysics Data System (ADS)
Jailaubekov, Askat E.; Song, Sang-Hun; Vengris, Mikas; Cogdell, Richard J.; Larsen, Delmar S.
2010-02-01
The hypothesis that S∗ is a vibrationally-excited ground-state population is tested and discarded for two carotenoid samples: β-carotene in solution and rhodopin glucoside embedded in the light harvesting 2 protein from Rhodopseudomonas acidophila. By demonstrating that the transient absorption signals measured in both systems that are induced by broadband (1000 cm -1) and narrowband (50 cm -1) excitation pulses are near identical and hence bandwidth independent, the impulsive stimulated Raman scattering mechanism proposed as the primary source for S∗ generation is discarded. To support this conclusion, previously published multi-pulse pump-dump-probe signals [17] are revisited to discard secondary mechanisms for S∗ formation.
Douglas, Emily M
2016-08-01
The purpose of this article was to examine the potential impact of child welfare services on the risk for fatal child maltreatment. This was conducted using a subsample of children who were identified as "prior victims" in the National Child Abuse and Neglect Data System from 2008 to 2012. At the multivariate level, the analyses show that case management services act to protect children from death as do family support services, family preservation services, and foster care, but that the results vary by type of maltreatment experienced. The author recommends that before strong conclusions are drawn, additional research in this area is warranted. © The Author(s) 2016.
Dynamic pathways for viral capsid assembly
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hagan, Michael F.; Chandler, David
2006-02-09
We develop a class of models with which we simulate the assembly of particles into T1 capsid-like objects using Newtonian dynamics. By simulating assembly for many different values of system parameters, we vary the forces that drive assembly. For some ranges of parameters, assembly is facile, while for others, assembly is dynamically frustrated by kinetic traps corresponding to malformed or incompletely formed capsids. Our simulations sample many independent trajectories at various capsomer concentrations, allowing for statistically meaningful conclusions. Depending on subunit (i.e., capsomer) geometries, successful assembly proceeds by several mechanisms involving binding of intermediates of various sizes. We discuss themore » relationship between these mechanisms and experimental evaluations of capsid assembly processes.« less
A usability evaluation of four commercial dental computer-based patient record systems
Thyvalikakath, Thankam P.; Monaco, Valerie; Thambuganipalle, Hima Bindu; Schleyer, Titus
2008-01-01
Background The usability of dental computer-based patient record (CPR) systems has not been studied, despite early evidence that poor usability is a problem for dental CPR system users at multiple levels. Methods The authors conducted formal usability tests of four dental CPR systems by using a purposive sample of four groups of five novice users. The authors measured task outcomes (correctly completed, incorrectly completed and incomplete) in each CPR system while the participants performed nine clinical documentation tasks, as well as the number of usability problems identified in each CPR system and their potential relationship to task outcomes. The authors reviewed the software application design aspects responsible for these usability problems. Results The range for correctly completed tasks was 16 to 64 percent, for incorrectly completed tasks 18 to 38 percent and for incomplete tasks 9 to 47 percent. The authors identified 286 usability problems. The main types were three unsuccessful attempts, negative affect and task incorrectly completed. They also identified six problematic interface and interaction designs that led to usability problems. Conclusion The four dental CPR systems studied have significant usability problems for novice users, resulting in a steep learning curve and potentially reduced system adoption. Clinical Implications The significant number of data entry errors raises concerns about the quality of documentation in clinical practice. PMID:19047669
Heterogeneity in the 238U/235U Ratios of Angrites.
NASA Astrophysics Data System (ADS)
Tissot, F.; Dauphas, N.; Grove, T. L.
2016-12-01
Angrites are differentiated meteorites of basaltic composition, of either volcanic or plutonic origin, that display minimal post-crystallization alteration, metamorphism, shock or impact brecciation. Because quenched angrites cooled very rapidly, all radiochronometric systems closed simultaneously in these samples. Quenched angrites are thus often used as anchors for cross-calibrating short-lived dating methods (e.g., 26Al-26Mg) and the absolute dating techniques (e.g, Pb-Pb). Due to the constancy of the 238U/235U ratio in natural samples, Pb-Pb ages have long been calculated using a "consensus" 238U/235U ratio, but the discovery of resolvable variations in the 238U/235U ratio of natural samples, means that the U isotopic composition of the material to date also has to be determined in order to obtain high-precision Pb-Pb ages. We set out (a) to measure at high-precision the 238U/235U ratio of a large array of angrites to correct their Pb-Pb ages, and (b) to identify whether all angrites have a similar U isotopic composition, and, if not, what were the processes responsible for this variability. Recently, Brennecka & Wadhwa (2012) suggested that the angrite-parent body had a homogeneous 238U/235U ratio. They reached this conclusion partly because they propagated the uncertainties of the U isotopic composition of the various U double spikes that they used onto the final 238U/235U ratio the sample. Because this error is systematic (i.e., it affects all samples similarly), differences in the δ238U values of samples corrected by the same double spike are better known than one would be led to believe if uncertainties on the spike composition are propagated. At the conference, we will present the results of the high-precision U isotope analyses for six angrite samples: NWA 4590, NWA 4801, NWA 6291, Angra dos Reis, D'Orbigny, and Sahara 99555. We will show that there is some heterogeneity in the δ238U values of the angrites and will discuss the possible processes by which different angrite samples can acquire different U isotopic compositions. The U isotope data will then be used to correct Pb-Pb ages of angrites estimated using an assumed 238U/235U ratio. These ages will be used to discuss the degree of concordance between short-lived nuclides systems and the absolute Pb-Pb clock in early Solar System materials.
Estimating the rate of biological introductions: Lessepsian fishes in the Mediterranean.
Belmaker, Jonathan; Brokovich, Eran; China, Victor; Golani, Daniel; Kiflawi, Moshe
2009-04-01
Sampling issues preclude the direct use of the discovery rate of exotic species as a robust estimate of their rate of introduction. Recently, a method was advanced that allows maximum-likelihood estimation of both the observational probability and the introduction rate from the discovery record. Here, we propose an alternative approach that utilizes the discovery record of native species to control for sampling effort. Implemented in a Bayesian framework using Markov chain Monte Carlo simulations, the approach provides estimates of the rate of introduction of the exotic species, and of additional parameters such as the size of the species pool from which they are drawn. We illustrate the approach using Red Sea fishes recorded in the eastern Mediterranean, after crossing the Suez Canal, and show that the two approaches may lead to different conclusions. The analytical framework is highly flexible and could provide a basis for easy modification to other systems for which first-sighting data on native and introduced species are available.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harman-Ware, Anne E.; Sykes, Robert; Peter, Gary F.
Terpenoids, naturally occurring compounds derived from isoprene units present in pine oleoresin, are a valuable source of chemicals used in solvents, fragrances, flavors, and have shown potential use as a biofuel. This paper describes a method to extract and analyze the terpenoids present in loblolly pine saplings and pine lighter wood. Various extraction solvents were tested over different times and temperatures. Samples were analyzed by pyrolysis-molecular beam mass spectrometry before and after extractions to monitor the extraction efficiency. The pyrolysis studies indicated that the optimal extraction method used a 1:1 hexane/acetone solvent system at 22°C for 1 h. Extracts frommore » the hexane/acetone experiments were analyzed using a low thermal mass modular accelerated column heater for fast-GC/FID analysis. The most abundant terpenoids from the pine samples were quantified, using standard curves, and included the monoterpenes, α- and β-pinene, camphene, and δ-carene. Sesquiterpenes analyzed included caryophyllene, humulene, and α-bisabolene. In conclusion, diterpenoid resin acids were quantified in derivatized extractions, including pimaric, isopimaric, levopimaric, palustric, dehydroabietic, abietic, and neoabietic acids.« less
A New Antibody for Category 1 Biomarker Detection
NASA Technical Reports Server (NTRS)
Maule, J.; Steele, A.; Toporski, J.; McKay, D. S.
2003-01-01
At least two questions arise in developing a life-detection strategy: What do we look for and what will positive detection tell us? Unfortunately, many 'biomarkers' are not conclusive markers of biology. For example, sugars, amino acids, polycyclic aromatic hydrocarbons (PAH) and certain bacteria-like morphologies can all be produced non-biologically. Inferences of life following the detection of several inconclusive biomarkers in one sample will always be questioned. Although DNA, RNA and proteins are excellent markers of biology, and preserved on Earth for several millions of years, their survival over longer periods of time is low. Ideally, we should target biomarkers which are both stable over time and formed exclusively from biological processes, i.e. a 'category 1' biomarker under the new classification system of Mckay. We have used antibodies to detect category 1 and other biomarkers in rock samples. Extraction takes a few minutes and analysis a few hours. We have presented use of new antibodies to detect hopanes and have shown proof of operation during martian gravity.
Matheson, Flora I.; Grant, Brian A.
2011-01-01
Objectives. We evaluated the effectiveness of the Community Relapse Prevention and Maintenance (CRPM) program, developed by Correctional Service Canada to better meet the needs of women offenders with drug problems. Methods. Using survival analysis, we investigated the association between exposure and nonexposure to CRPM and return to custody among a national sample of women offenders released from 1 of 6 federal institutions across Canada during the period May 1, 1998 to August 31, 2007. Results. After control for other risk factors, women who were not exposed to CRPM were 10 times more likely than were women exposed to CRPM to return to custody 1 year after release from prison, with more than a third returning to prison within the first 6 months. Conclusions. Aftercare is a critical component of a woman's support system after she leaves prison. Strategies that improve access to community aftercare are imperative for improving the life chances and health of these women. PMID:21493930
de Morais Lima, Gedson Rodrigues; Machado, Flavia Danniele Frota; Périco, Larissa Lucena; de Faria, Felipe Meira; Luiz-Ferreira, Anderson; Souza Brito, Alba Regina Monteiro; Pellizzon, Cláudia Helena; Hiruma-Lima, Clélia Akiko; Tavares, Josean Fechine; Barbosa Filho, José Maria; Batista, Leônia Maria
2017-01-01
AIM To evaluate the anti-inflammatory intestinal effect of the ethanolic extract (EtOHE) and hexane phase (HexP) obtained from the leaves of Combretum duarteanum (Cd). METHODS Inflammatory bowel disease was induced using trinitrobenzenesulfonic acid in acute and relapsed ulcerative colitis in rat models. Damage scores, and biochemical, histological and immunohistochemical parameters were evaluated. RESULTS Both Cd-EtOHE and Cd-HexP caused significant reductions in macroscopic lesion scores and ulcerative lesion areas. The vegetable samples inhibited myeloperoxidase increase, as well as pro-inflammatory cytokines TNF-α and IL-1β. Anti-inflammatory cytokine IL-10 also increased in animals treated with the tested plant samples. The anti-inflammatory intestinal effect is related to decreased expression of cyclooxygenase-2, proliferating cell nuclear antigen, and an increase in superoxide dismutase. CONCLUSION The data indicate anti-inflammatory intestinal activity. The effects may also involve participation of the antioxidant system and principal cytokines relating to inflammatory bowel disease. PMID:28293082
NASA Astrophysics Data System (ADS)
Manzerova, Julia; Krymov, Vladimir; Gerfen, Gary J.
2011-12-01
In this investigation high-frequency electron paramagnetic resonance spectroscopy (HFEPR) in conjunction with innovative rapid freeze-quench (RFQ) technology is employed to study the exchange-coupled thiyl radical-cob(II)alamin system in ribonucleotide reductase from a prokaryote Lactobacillus leichmannii. The size of the exchange coupling ( Jex) and the values of the thiyl radical g tensor are refined, while confirming the previously determined (Gerfen et al. (1996) [20]) distance between the paramagnets. Conclusions relevant to ribonucleotide reductase catalysis and the architecture of the active site are presented. A key part of this work has been the development of a unique RFQ apparatus for the preparation of millisecond quench time RFQ samples which can be packed into small (0.5 mm ID) sample tubes used for CW and pulsed HFEPR - lack of this ability has heretofore precluded such studies. The technology is compatible with a broad range of spectroscopic techniques and can be readily adopted by other laboratories.
Analysis of injury types for mixed martial arts athletes
Ji, MinJoon
2016-01-01
[Purpose] The purpose of the present study was to examine the types of injuries associated with mixed martial arts and their location in order to provide substantial information to help reduce the risk of these injuries during mixed martial arts. [Subjects and Methods] Data were collected from 455 mixed martial arts athletes who practiced mixed martial arts or who participated in mixed martial arts competitions in the Seoul Metropolitan City and Gyeongnam Province of Korea between June 3, 2015, and November 6, 2015. Questionnaires were used to collect the data. The convenience sampling method was used, based on the non-probability sampling extraction method. [Results] The arm, neck, and head were the most frequent locations of the injuries; and lacerations, concussions, and contusions were the most frequently diagnosed types of injuries in the mixed martial arts athletes in this study. [Conclusion] Reducing the risk of injury by establishing an alert system and preventing critical injuries by incorporating safety measures are important. PMID:27313367
Analysis of injury types for mixed martial arts athletes.
Ji, MinJoon
2016-05-01
[Purpose] The purpose of the present study was to examine the types of injuries associated with mixed martial arts and their location in order to provide substantial information to help reduce the risk of these injuries during mixed martial arts. [Subjects and Methods] Data were collected from 455 mixed martial arts athletes who practiced mixed martial arts or who participated in mixed martial arts competitions in the Seoul Metropolitan City and Gyeongnam Province of Korea between June 3, 2015, and November 6, 2015. Questionnaires were used to collect the data. The convenience sampling method was used, based on the non-probability sampling extraction method. [Results] The arm, neck, and head were the most frequent locations of the injuries; and lacerations, concussions, and contusions were the most frequently diagnosed types of injuries in the mixed martial arts athletes in this study. [Conclusion] Reducing the risk of injury by establishing an alert system and preventing critical injuries by incorporating safety measures are important.
Dye-Enhanced Multimodal Confocal Imaging of Brain Cancers
NASA Astrophysics Data System (ADS)
Wirth, Dennis; Snuderl, Matija; Sheth, Sameer; Curry, William; Yaroslavsky, Anna
2011-04-01
Background and Significance: Accurate high resolution intraoperative detection of brain tumors may result in improved patient survival and better quality of life. The goal of this study was to evaluate dye enhanced multimodal confocal imaging for discriminating normal and cancerous brain tissue. Materials and Methods: Fresh thick brain specimens were obtained from the surgeries. Normal and cancer tissues were investigated. Samples were stained in methylene blue and imaged. Reflectance and fluorescence signals were excited at 658nm. Fluorescence emission and polarization were registered from 670 nm to 710 nm. The system provided lateral resolution of 0.6 μm and axial resolution of 7 μm. Normal and cancer specimens exhibited distinctively different characteristics. H&E histopathology was processed from each imaged sample. Results and Conclusions: The analysis of normal and cancerous tissues indicated clear differences in appearance in both the reflectance and fluorescence responses. These results confirm the feasibility of multimodal confocal imaging for intraoperative detection of small cancer nests and cells.
40 CFR 91.327 - Sampling system requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Sampling system requirements. 91.327....327 Sampling system requirements. (a) Sample component surface temperature. For sampling systems which..., sample line section, filters, and so forth) in the heated portion of the sampling system that has a...
40 CFR 91.327 - Sampling system requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Sampling system requirements. 91.327....327 Sampling system requirements. (a) Sample component surface temperature. For sampling systems which..., sample line section, filters, and so forth) in the heated portion of the sampling system that has a...
NASA Astrophysics Data System (ADS)
Storms, Max
Membrane systems are among the primary emergent technologies in water treatment process units due to their ease of use, small physical footprint, and high physical rejection. Membrane fouling, the phenomena by which membranes become clogged or generally soiled, is an inhibitor to optimal efficiency in membrane systems. Novel, composite, and modified surface materials must be investigated to determine their efficacy in improving fouling behavior. Ceramic membranes derived from iron oxide nanoparticles called ferroxanes were coated with a superhydrophillic, zwitterionic polymer called poly (sulfobetaine methacrylate) (polySBMA) to form a composite ceramic-polymeric membrane. Membrane samples with and without polySBMA coating were subjected to fouling with a bovine serum albumin solution and fouling was observed by measuring permeate flux at 10 mL intervals. Loss of polySBMA was measured using total organic carbon analysis, and membrane samples were characterized using x-ray diffraction, scanning electron microscopy, and optical profilometry. The coated membrane samples decreased initial fouling rate by 27% and secondary fouling rate by 24%. Similarly, they displayed a 30% decrease in irreversible fouling during the initial fouling stage, and a 27% decrease in irreversible fouling in the secondary fouling stage; however, retention of polySBMA sufficient for improved performance was not conclusive. The addition of chemical disinfectants into drinking water treatment processes results in the formation of compounds called disinfection by-products (DBPs). The formation of DBPs occurs when common chemical disinfectants (i.e. chlorine) react with organic material. The harmful effects of DBP exposure require that they be monitored and controlled for public safety. This work investigated the ability of nanostructured hematite derived from ferroxane nanoparticles to remove organic precursors to DBPs in the form of humic acid via adsorption processes. The results show that pH and ionic strength have an effect on adsorption capacity and mechanism. At lower ionic strengths, the adsorption isotherms are closely correlated with the Freundlich adsorption isotherm model, while at higher ionic strength, the isotherms are closely related to the Langmuir adsorption isotherm model. Lower pH systems facilitate better adsorption capacities than higher pH systems, and lower ionic strength systems facilitate better adsorption than higher ionic strength systems.
Yong, Dongeun; Ki, Chang-Seok; Kim, Jae-Seok; Seong, Moon-Woo; Lee, Hyukmin
2016-01-01
Background Real-time reverse transcription PCR (rRT-PCR) of sputum samples is commonly used to diagnose Middle East respiratory syndrome coronavirus (MERS-CoV) infection. Owing to the difficulty of extracting RNA from sputum containing mucus, sputum homogenization is desirable prior to nucleic acid isolation. We determined optimal homogenization methods for isolating viral nucleic acids from sputum. Methods We evaluated the following three sputum-homogenization methods: proteinase K and DNase I (PK-DNase) treatment, phosphate-buffered saline (PBS) treatment, and N-acetyl-L-cysteine and sodium citrate (NALC) treatment. Sputum samples were spiked with inactivated MERS-CoV culture isolates. RNA was extracted from pretreated, spiked samples using the easyMAG system (bioMérieux, France). Extracted RNAs were then subjected to rRT-PCR for MERS-CoV diagnosis (DiaPlex Q MERS-coronavirus, SolGent, Korea). Results While analyzing 15 spiked sputum samples prepared in technical duplicate, false-negative results were obtained with five (16.7%) and four samples (13.3%), respectively, by using the PBS and NALC methods. The range of threshold cycle (Ct) values observed when detecting upE in sputum samples was 31.1–35.4 with the PK-DNase method, 34.7–39.0 with the PBS method, and 33.9–38.6 with the NALC method. Compared with the control, which were prepared by adding a one-tenth volume of 1:1,000 diluted viral culture to PBS solution, the ranges of Ct values obtained by the PBS and NALC methods differed significantly from the mean control Ct of 33.2 (both P<0.0001). Conclusions The PK-DNase method is suitable for homogenizing sputum samples prior to RNA extraction. PMID:27374711
Examination of Duct Physiology in the Human Mammary Gland
Mills, Dixie; Gomberawalla, Ameer; Gordon, Eva J.; Tondre, Julie; Nejad, Mitra; Nguyen, Tinh; Pogoda, Janice M.; Rao, Jianyu; Chatterton, Robert; Henning, Susanne; Love, Susan M.
2016-01-01
Background The human breast comprise several ductal systems, or lobes, which contain a small amount of fluid containing cells, hormones, proteins and metabolites. The complex physiology of these ducts is likely a contributing factor to the development of breast cancer, especially given that the vast majority of breast cancers begin in a single lobular unit. Methods We examined the levels of total protein, progesterone, estradiol, estrone sulfate, dehydroepiandrosterone sulfate, and macrophages in ductal fluid samples obtained from 3 ducts each in 78 women, sampled twice over a 6 month period. Samples were processed for both cytological and molecular analysis. Intraclass correlation coefficients and mixed models were utilized to identify significant data. Results We found that the levels of these ductal fluid components were generally uncorrelated among ducts within a single breast and over time, suggesting that each lobe within the breast has a distinct physiology. However, we also found that estradiol was more correlated in women who were nulliparous or produced nipple aspirate fluid. Conclusions Our results provide evidence that the microenvironment of any given lobular unit is unique to that individual unit, findings that may provide clues about the initiation and development of ductal carcinomas. PMID:27073976
Content and Form in the Narratives of Children with Specific Language Impairment
Colozzo, Paola; Gillam, Ronald B.; Wood, Megan; Schnell, Rebecca D.; Johnston, Judith R.
2013-01-01
Purpose: This project investigated the relationship of content and form in the narratives of school-age children. Method: Two samples of children with specific language impairment (SLI) and their age-matched peers (British Columbia sample, M age 9;0, n = 26; Texas/Kansas sample, M age 7;6, n = 40) completed the Test of Narrative Language (TNL, Gillam & Pearson, 2004). The relative strength of content elaboration and grammatical accuracy was measured for each child using variables derived from the TNL scoring system (Study 1) and from analysis of the story texts (Study 2). Results: Both studies indicated that, compared to age peers, the children with SLI were more likely to produce stories of uneven strength, either stories with poor content that were grammatically quite accurate, or stories with elaborated content that were less grammatical. Conclusions: These findings suggest that school-age children with SLI may struggle with the cumulative load of creating a story that is both elaborate and grammatical. They also show that the absence of errors is not necessarily a sign of strength. Finally, they underscore the value of comparing individual differences in multiple linguistic domains, including the elaboration of content, grammatical accuracy, and syntactic complexity. PMID:21930617
Reproductive tract infections: prevalence and risk factors in rural Bangladesh.
Hawkes, Sarah; Morison, Linda; Chakraborty, Jyotsnamoy; Gausia, Kaniz; Ahmed, Farid; Islam, Shamim Sufia; Alam, Nazmul; Brown, David; Mabey, David
2002-01-01
OBJECTIVE: To determine the prevalence of and risk factors for reproductive tract infections among men and women in a rural community in Bangladesh. METHODS: In the Matlab area a systematic sample of married non-pregnant women aged 15-50 years was drawn from a comprehensive household registration system for married women. A systematic sample of married and unmarried men in the same age group was drawn from a census-derived demographic surveillance list. Private interviews were conducted with 804 women in a clinic, and cervical, vaginal, urinary and serological samples were collected. Urine and blood specimens were obtained from 969 men who were interviewed at home. FINDINGS: The prevalence of bacterial and viral reproductive tract infections was low to moderate. For example, fewer than 1% of the women had a cervical infection. No cases of human immunodeficiency virus (HIV) infection were found. However, among men there was a high level of reported risk behaviour and a low level of protection against infection. CONCLUSION: A low prevalence of reproductive tract infections, coupled with a high level of reported risk behaviour, indicated a need for primary programmes that would prevent an increase in the incidence of reproductive tract infections, sexually transmitted infections and HIV infection. PMID:11984603
Analysis of HbA1c on an automated multicapillary zone electrophoresis system.
Rollborn, Niclas; Åkerfeldt, Torbjörn; Nordin, Gunnar; Xu, Xiao Yan; Mandic-Havelka, Aleksandra; Hansson, Lars-Olof; Larsson, Anders
2017-02-01
Hemoglobin A1c (HbA1c) is a frequently requested laboratory test and there is thus a need for high throughput instruments for this assay. We evaluated a new automated multicapillary zone electrophoresis instrument (Capillarys 3 Tera, Sebia, Lisses, France) for analysis of HbA1c in venous samples. Routine requested HbA1c samples were analyzed immunologically on a Roche c6000 instrument (n = 142) and then with the Capillarys 3 Tera instrument. The Capillarys 3 Tera instrument performed approximately 70 HbA1c tests/hour. There was a strong linear correlation between Capillarys 3 Tera and Roche Tina-Quant HbA1c Gen 3 assay (y = 1.003x - 0.3246 R 2 = .996). The total CV for the 12 capillaries varied between 0.8 and 2.2% and there was a good agreement between duplicate samples (R 2 = .997). In conclusion, the Capillarys 3 Tera instrument has a high assay capacity for HbA1c. It has a good precision and agreement with the Roche Tina-Quant HbA1c method and is well suited for high volume testing of HbA1c.
Ranganathan, Anjana; Dougherty, Meredith; Waite, David
2013-01-01
Abstract Objective This study examined the impact of palliative home nursing care on rates of hospital 30-day readmissions. Methods The electronic health record based retrospective cohort study was performed within home care and palliative home care programs. Participants were home care patients discharged from one of three urban teaching hospitals. Outcome measures were propensity score matched rates of hospital readmissions within 30 days of hospital discharge. Results Of 406 palliative home care patients, matches were identified for 392 (96%). Of 15,709 home care patients, 890 were used at least once as a match for palliative care patients, for a total final sample of 1282. Using the matched sample we calculated the average treatment effect for treated patients. In this sample, palliative care patients had a 30-day readmission probability of 9.1% compared to a probability of 17.4% in the home care group (mean ATT: 8.3%; 95% confidence interval [CI] 8.0%–8.6%). This effect persisted after adjustment for visit frequency. Conclusions Palliative home care may offer benefits to health systems by allowing patients to remain at home and thereby avoiding 30-day rehospitalizations. PMID:24007348
Chen, Jie; Huang, Chaozhang; Hu, Bin; Jiang, Zucheng
2004-11-17
A technique using a flow injection microcolumn separation coupled with ICP-MS detection has been developed for the speciation of Al in drink samples. The retention behaviors of different Al species were studied with 8-hydroxyquinoline (8-HQ) loaded silylanization silica gel as the packing material and inorganic acid (HNO3) as the elution. The results indicated that in a pH range of 5.0 to 8.0, all labile monomeric Al species were retained on the microcolumn while nonlabile monomeric Al species were directly passed through the column. Various Al species after separation were detected by ICP-MS. The detection limit of 0.2 ng mL(-1) and a relative standard deviation (RSD) of 4.2% at 10 ng mL(-1) (n = 11) were achieved, and the recoveries for the spiked samples were 95-108%. The proposed method has been applied to the analysis of Al species in tea infusions, coffee, and tap waters with satisfactory results. The results obtained by this method were compared with that obtained by the cation exchange microcolumn separation and ICP-MS detection system, and some valuable conclusions were drawn.
Stojek, Nimfa Maria; Wójcik-Fatla, Angelina; Dutkiewicz, Jacek
2012-01-01
A total of 123 water samples were examined in parallel by culture and semi-nested PCR for the presence of Legionella. They comprised: 35 samples of hot water distributed by the urban municipal water supply system (MWSS) taken in institutions, 45 samples of hot water distributed by urban MWSS taken in dwellings, 27 samples of cold water distributed by rural MWSS taken in dwellings, and 16 samples of cold well water taken in rural areas. The greatest frequency of the isolation of Legionella by culture (88.6%) was recorded in the samples of hot water from the urban institutions, having been greater compared to all other sources (p<0.001). The frequency of Legionella isolation from hot water in urban dwellings (28.9%) was significantly greater compared to the combined value (2.3%) for cold water from rural MWSS and wells (p<0.001). Strains belonging to Legionella pneumophila serogroups 2-14 predominated in the examined samples, while strains of L. pneumophila serogroup 1 and strains of Legionella spp. (other than L. pneumophila) were 3-fold less numerous. The rates of positive findings in the semi-nested PCR (stage 2) were greater than culture isolations in all kinds of samples, except for urban institutions. The correlation between the culture and PCR results was positive for samples of hot water from urban MWSS (p<0.01), but not for samples of cold water from rural MWSS and wells (p>0.5). A significant correlation was found between rates of PCR-positive results and numbers of Legionella pneumophila serogroups 2-14 strains, but not for other Legionella serogroups or species. In conclusion, our results support the opinion that though PCR cannot be a substitute for the isolation of Legionella by culture, it could be regarded as an useful complementary method.
40 CFR 63.166 - Standards: Sampling connection systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Standards: Sampling connection systems...: Sampling connection systems. (a) Each sampling connection system shall be equipped with a closed-purge... defined in 40 CFR part 261. (c) In-situ sampling systems and sampling systems without purges are exempt...
40 CFR 63.166 - Standards: Sampling connection systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Standards: Sampling connection systems...: Sampling connection systems. (a) Each sampling connection system shall be equipped with a closed-purge... defined in 40 CFR part 261. (c) In-situ sampling systems and sampling systems without purges are exempt...
40 CFR 60.482-5 - Standards: Sampling connection systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards: Sampling connection systems... Standards: Sampling connection systems. (a) Each sampling connection system shall be equipped with a closed... sampling systems and sampling systems without purges are exempt from the requirements of paragraphs (a) and...
40 CFR 60.482-5 - Standards: Sampling connection systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards: Sampling connection systems... Standards: Sampling connection systems. (a) Each sampling connection system shall be equipped with a closed... sampling systems and sampling systems without purges are exempt from the requirements of paragraphs (a) and...
Snyder, Robert L.; Frederick-Hudson, Katy H.; Schul, Johannes
2009-01-01
Background The katydid genus Neoconocephalus (25+ species) has a prominent acoustic communication system and occurs in large parts of the Neotropics and Nearctic. This group has been subject of numerous behavioral, physiological, and evolutionary studies of its acoustic communication system. Two distinct life histories occur in this group: The tropical life history incorporates multiple generations/year and direct egg development without environmental triggers. Temperate life history is characterized by overwintering in the egg stage, cold trigger of egg development, and one generation/year. This study reconstructs the phylogenetic relationships within the genus to (1) determine the evolutionary history of the temperate life history, and (2) to support comparative studies of evolutionary and physiological problems in this genus. Methodology/Principal Findings We used Amplified Fragment Length Polymorphisms (AFLP), and sequences of two nuclear loci and one mitochondrial locus to reconstruct phylogenetic relationships. The analysis included 17 ingroup and two outgroup species. AFLP and mitochondrial data provided resolution at the species level while the two nuclear loci revealed only deeper nodes. The data sets were combined in a super-matrix to estimate a total evidence tree. Seven of the temperate species form a monophyletic group; however, three more temperate species were placed as siblings of tropical species. Conclusions/Significance Our analyses support the reliability of the current taxonomic treatment of the Neoconocephalus fauna of Caribbean, Central, and North America. Ancestral state reconstruction of life history traits was not conclusive, however at least four transitions between life histories occurred among our sample of species. The proposed phylogeny will strengthen conclusions from comparative work in this group. PMID:19779617
Mars Orbiter Sample Return Power Design
NASA Technical Reports Server (NTRS)
Mardesich, N.; Dawson, S.
2005-01-01
Mars has greatly intrigued scientists and the general public for many years because, of all the planets, its environment is most like Earth's. Many scientists believe that Mars once had running water, although surface water is gone today. The planet is very cold with a very thin atmosphere consisting mainly of CO2. Mariner 4, 6, and 7 explored the planet in flybys in the 1960s and by the orbiting Mariner 9 in 1971. NASA then mounted the ambitious Viking mission, which launched two orbiters and two landers to the planet in 1975. The landers found ambiguous evidence of life. Mars Pathfinder landed on the planet on July 4, 1997, delivering a mobile robot rover that demonstrated exploration of the local surface environment. Mars Global Surveyor is creating a highest-resolution map of the planet's surface. These prior and current missions to Mars have paved the way for a complex Mars Sample Return mission planned for 2003 and 2005. Returning surface samples from Mars will necessitate retrieval of material from Mars orbit. Sample mass and orbit are restricted to the launch capability of the Mars Ascent Vehicle. A small sample canister having a mass less than 4 kg and diameter of less than 16 cm will spend from three to seven years in a 600 km orbit waiting for retrieval by a second spacecraft consisting of an orbiter equipped with a sample canister retrieval system, and a Earth Entry Vehicle. To allow rapid detection of the on-orbit canister, rendezvous, and collection of the samples, the canister will have a tracking beacon powered by a surface mounted solar array. The canister must communicate using RF transmission with the recovery vehicle that will be coming in 2006 or 2009 to retrieve the canister. This paper considers the aspect and conclusion that went into the design of the power system that achieves the maximum power with the minimum risk. The power output for the spherical orbiting canister was modeled and plotted in various views of the orbit by the Satellite Orbit Analysis Program (SOAP).
Lohiya, Ayush; Kapil, Arti; Gupta, Sanjeev Kumar; Misra, Puneet; Rai, Sanjay K.
2015-01-01
Background Despite world-wide evidence of increased antibiotic resistance, there is scarce data on antibiotic resistance in community settings. One of the reason being difficulty in collection of biological specimen (traditionally stool) in community from apparently healthy individuals. Hence, finding an alternative specimen that is easier to obtain in a community setting or in large scale surveys for the purpose, is crucial. We conducted this study to explore the feasibility of using urine samples for deriving community based estimates of antibiotic resistance and to estimate the magnitude of resistance among urinary isolates of Escherichia coli and Klebsiella pneumonia against multiple antibiotics in apparently healthy individuals residing in a rural community of Haryana, North India. Materials and Methods Eligible individuals were apparently healthy, aged 18 years or older. Using the health management information system (HMIS) of Ballabgarh Health Demographic Surveillance System (HDSS), sampling frame was prepared. Potential individuals were identified using simple random sampling. Random urine sample was collected in a sterile container and transported to laboratory under ambient condition. Species identification and antibiotic susceptibility testing for Enterobacteriaceae was done using Clinical Laboratory and Standards Institute (CLSI) 2012 guidelines. Multi-drug resistant (MDR) Enterobacteriaceae, Extended Spectrum Beta Lactamase (ESBL) producing Enterobacteriaceae, and Carbapenem producing Enterobacteriaceae (CRE) were identified from the urine samples. Results A total of 433 individuals participated in the study (non-response rate – 13.4%), out of which 58 (13.4%) were positive for Enterobacteriaceae, 8.1% for E. coli and 5.3% for K. pneumoniae. Resistance against penicillin (amoxicillin/ampicillin) for E. coli and K. pneumoniae was 62.8% and 100.0% respectively. Isolates resistant to co-trimoxazole were 5.7% and 0.0% respectively. None of the isolates were resistant to imipenem, and meropenem. Conclusion and recommendations It is feasible to use urine sample to study magnitude of antibiotic resistance in population based surveys. At community level, resistance to amoxicillin was considerable, negligible for co-trimoxazole, and to higher antibiotics including carbapenems. PMID:26393150
[Personality and emesis in the patient treated with antineoplastic chemotherapy].
Llorca, G; Martín, T; Derecho, J; Gómez, M J
1991-01-01
A sample of twenty cancer patients following chemotherapy realize MMPI questionnaire, and another one for valuation of emetic and anticipatory phenomena in relation to said therapy. The authors came to the conclusion that 36.8% of the sample had anticipatory nausea and vomiting, 63.6% anticipatory dysphoria, and 66% emetic incidents after chemotherapy. The conclusion, through comparison of personality variables, is that all patients showed neuroticism and depression scales increased, in relation to healthy population. Depression variable increased especially in patients that didn't present anticipatory nausea and vomiting. Likewise, patients with anticipatory symptoms or emetic incidents after chemotherapy present an increased social introversion variable.
Somers, Julian M.; Rezansoff, Stefanie N.; Moniruzzaman, Akm; Palepu, Anita; Patterson, Michelle
2013-01-01
Background Homelessness and mental illness have a strong association with public disorder and criminality. Experimental evidence indicates that Housing First (HF) increases housing stability and perceived choice among those experiencing chronic homelessness and mental disorders. HF is also associated with lower residential costs than common alternative approaches. Few studies have examined the effect of HF on criminal behavior. Methods Individuals meeting criteria for homelessness and a current mental disorder were randomized to one of three conditions treatment as usual (reference); scattered site HF; and congregate HF. Administrative data concerning justice system events were linked in order to study prior histories of offending and to test the relationship between housing status and offending following randomization for up to two years. Results The majority of the sample (67%) was involved with the justice system, with a mean of 8.07 convictions per person in the ten years prior to recruitment. The most common category of crime was “property offences” (mean = 4.09). Following randomization, the scattered site HF condition was associated with significantly lower numbers of sentences than treatment as usual (Adjusted IRR = 0.29; 95% CI 0.12–0.72). Congregate HF was associated with a marginally significant reduction in sentences compared to treatment as usual (Adjusted IRR = 0.55; 95% CI: 0.26–1.14). Conclusions This study is the first randomized controlled trial to demonstrate benefits of HF among a homeless sample with mental illness in the domain of public safety and crime. Our sample was frequently involved with the justice system, with great personal and societal costs. Further implementation of HF is strongly indicated, particularly in the scattered site format. Research examining interdependencies between housing, health, and the justice system is indicated. Trial registration ISRCTN57595077 PMID:24023796
Linnan, Laura A; Arandia, Gabriela; Naseer, Carolyn; Li, Jiang; Pomerantz, Meg; Diehl, Sandra J
2017-01-01
BACKGROUND North Carolina has the third largest community college system in the nation and reaches residents in all 100 counties. Few studies have focused on the health of employees who work at these institutions. We assessed the current status of and interest in supporting health promotion efforts among North Carolina Community College System members. METHODS North Carolina Community College System presidents completed a brief 15-item survey assessing support for and interest in offering health promotion programs. Wellness coordinators completed a 60-item questionnaire assessing current health promotion programming and organizational, environmental, and policy supports for health promotion efforts. Onsite interviews with a sub-sample of Wellness coordinators offered insights into important implementation considerations. We examined differences by campus size with Fisher's exact test. RESULTS All 58 presidents (100%) and 51 wellness coordinators (88%) completed surveys. Ten percent of colleges offered comprehensive employee health promotion programming. Most offered physical activity (70.6%), tobacco cessation (51.0%), weight loss/management (49.0%), and/or nutrition counseling (47.1%). Larger colleges were more likely to offer programming and environmental support. Nearly all presidents (89.7%) believed it is "very" or "extremely" important to offer health promotion programs to employees, and most (84%) were interested in promoting health through a university partnership. LIMITATIONS Despite very high survey response rates from presidents and wellness coordinators at each community college, onsite interviews were only done at select campuses, limiting the generalizability and scope of conclusions derived from interview data. CONCLUSION Community colleges in North Carolina are promising settings for promoting employee health. Findings identify resources, barriers, and technical assistance that could facilitate greater adoption and implementation of programs. ©2017 by the North Carolina Institute of Medicine and The Duke Endowment. All rights reserved.
40 CFR 86.1509 - Exhaust gas sampling system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Exhaust gas sampling system. 86.1509... Procedures § 86.1509 Exhaust gas sampling system. (a) The exhaust gas sampling system shall transport the... sample (i.e., water removed) to the analysis system. (c) A CVS sampling system with bag or continuous...
Electron transport in ferromagnetic nanostructures
NASA Astrophysics Data System (ADS)
Lee, Sungbae
As the size of a physical system decreases toward the nanoscale, quantum mechanical effects such as the discretization of energy levels and the interactions of the electronic spins become readily observable. To understand what happens within submicrometer scale samples is one of the goals of modern condensed matter physics. Electron transport phenomena drew a lot of attention over the past two decades or so, not only because quantum corrections to the classical transport theory, but also they allow us to probe deeply into the microscopic nature of the system put to test. Although a significant amount of research was done in the past and thus extended our understanding in this field, most of these works were concentrated on simpler examples. Electron transport in strongly correlated systems is still a field that needs to be explored more thoroughly. In fact, experimental works that have been done so far to characterize coherence physics in correlated systems such as ferromagnetic metals are far from conclusive. One reason ferromagnetic samples draw such attention is that there exist correlations that lead to excitations (e.g. spin waves, domain wall motions) not present in normal metals, and these new environmental degrees of freedom can have profound effects on decoherence processes. In this thesis, three different types of magnetic samples were examined: a band ferromagnetism based metallic ferromagnet, permalloy, a III-V diluted ferromagnetic semiconductor with ferromagnetism from a hole-mediated exchange interaction, and magnetite nanocrystals and films. The first observation of time-dependent universal conductance fluctuations (TD-UCF) in permalloy is presented and our observations lead to three major conclusions. First, the cooperon contribution to the conductance is suppressed in this material. This is consistent with some theoretical expectations, and implies that weak localization will be suppressed as well. Second, we see evidence that domain wall motion leads to enhanced conductance fluctuations, demonstrating experimentally that domain walls can act as coherent scatterers of electrons. Third, the temperature dependence of the fluctuations is surprisingly strong, suggesting that the dominant decoherence mechanism in these wires is different than that in similar normal metal nanostructures. The first observation of TD-UCF in diluted magnetic semiconductors (DMS) is also presented. In contrast to analogous measurements on permalloy samples, we find a surprising suppression of TD-UCF noise in this material at low temperatures, independent of field orientation. We believe this implies that the suppression is not due to an orbital effect, and therefore some of the fluctuations originate with time-varying magnetic disorder. The temperature dependence of the TD-UCF implies either an unusual fluctuator spectrum or a nonstandard dephasing mechanism. Measurements of UCF as a function of magnetic field allow an order of magnitude estimate of the coherence length at 2 K of approximately 50 nm in this material. The last samples examined were magnetite nanocrystals and films. Magnetite has been used in technologies for millennia, from compasses to magnetoelectronic devices, although its electronic structure has remained controversial for seven decades, with a low temperature insulator and a high temperature "bad metal" separated by the Verwey transition at 120 K. A new electrically driven insulator-metal transition below the Verwey temperature in both magnetite films and nanocrystals was observed. The possibility that this was a thermal effect was tested through various methods, and we have shown that the transition is in fact truly electrically driven. This electrically driven transition also showed a great deal of rigidity against external magnetic field and high gate voltages.
Love, Heather M.; Maggs, Christine A.; Murray, Tomás E.; Provan, Jim
2013-01-01
Background and Aims Riparian systems are prone to invasion by alien plant species. The spread of invasive riparian plants may be facilitated by hydrochory, the transport of seeds by water, but while ecological studies have highlighted the possible role of upstream source populations in the establishment and persistence of stands of invasive riparian plant species, population genetic studies have as yet not fully addressed the potential role of hydrochoric dispersal in such systems. Methods A population genetics approach based on a replicated bifurcate sampling design is used to test hypotheses consistent with patterns of unidirectional, linear gene flow expected under hydrochoric dispersal of the invasive riparian plant Impatiens glandulifera in two contrasting river systems. Key results A significant increase in levels of genetic diversity downstream was observed, consistent with the accumulation of propagules from upstream source populations, and strong evidence was found for organization of this diversity between different tributaries, reflecting the dendritic organization of the river systems studied. Conclusions These findings indicate that hydrochory, rather than anthropogenic dispersal, is primarily responsible for the spread of I. glandulifera in these river systems, and this is relevant to potential approaches to the control of invasive riparian plant species. PMID:24169594
Temperature Increase during Different Post Space Preparation Systems: An In Vitro Study
Nazari Moghadam, Kiumars; Shahab, Shahriar; Shirvani, Soghra; Kazemi, Ali
2011-01-01
INTRODUCTION: The purpose of this study was to evaluate external root surface temperature rise during post space preparation using LA Axxess bur, Beefill pack System, and Peeso Reamer drill. MATERIALS AND METHODS: The distal canals of forty-five extracted human permanent mandibular first molars were instrumented in crown-apical manner and obturated with lateral condensation technique. Teeth were then randomly divided into three groups according to post space preparation technique including: group 1. LA Axxess bur (Sybronendo Co., CA, USA), group 2 Beefill pack System (VD W Co., Munich, Germany) and group 3 Peeso Reamer drill (Mani Co., Tochigi-ken, Japan). Temperature was measured by means of digital thermometer MT-405 (Comercio Co., Sao Paulo, Brazil) which was installed on the root surfaces. Data was collected and submitted to one-way ANOVA and Post hoc analysis. RESULTS: Root surface temperatures were found to be significantly higher (7.3±2.7 vs. 4.3±2.1 and 4±2.4,) in samples of Beefill pack System compared with the two other groups (P<0.02). CONCLUSION: Using Beefill pack System during post space preparation may be potentially hazardous for periodontal tissues. PMID:24778690
Pediatric Palliative Care in Iran: Applying Regionalization of Health Care Systems
Khanali Mojen, Leila; Rassouli, Maryam; Eshghi, Peyman; Zendedel, Kazem; Akbari Sari, Ali; Heravi Karimooi, Majideh; Tahmasebi, Mamak; Shirin Abadi Farahani, Azam
2018-05-26
Background: Establishing palliative care services is a priority in the health system of Iran. Considering the necessity of integrating these services into the health system, this study aimed to explore the stakeholders’ perceptions about the provision of a conceptual framework for palliative care services for children with cancer according to the health system in of Iran. Methods: The present qualitative study was conducted through in-depth semi-structured interviews held with 29 participants including palliative care specialists, policy-makers, health care providers, the parents of children with cancer selected through purposive sampling, between August 2016 and February 2017. Interviews continued until saturation of data. All interviews were recorded, transcribed and analyzed using MAXQDA10 software. Results: The codes extracted from interviews produced the main theme “ classes of palliative care services” with the two main categories “comprehensive care” including, strengthening family shelter, maintaining the child in a familiar environment, achieving stability and “establishing social justice” including, easy access to services, financial relief and quality care. Conclusion: Presenting a framework based on level of palliative care services, the findings of this study paves the way for integrating these services into Iranian health system. Creative Commons Attribution License
Primary care and communication in shared cancer care: A Qualitative Study
Sada, Yvonne; Street, Richard L.; Singh, Hardeep; Shada, Rachel; Naik, Aanand D.
2013-01-01
Objective To explore perceptions of primary care physicians’ (PCPs) and oncologists’ roles, responsibilities, and patterns of communication related to shared cancer care in three integrated health systems that used electronic health records (EHRs). Study design Qualitative study. Methods We conducted semi-structured interviews with ten early stage colorectal cancer patients and fourteen oncologists and PCPs. Sample sizes were determined by thematic saturation. Dominant themes and codes were identified and subsequently applied to all transcripts. Results Physicians reported that EHRs improved communication within integrated systems, but communication with physicians outside their system was still difficult. PCPs expressed uncertainty about their role during cancer care, even though medical oncologists emphasized the importance of co-morbidity control during cancer treatment. Both patients and physicians described additional roles for PCPs, including psychological distress support and behavior modification. Conclusions Integrated systems that use EHRs likely facilitate shared cancer care through improved PCP-oncologist communication. However, strategies to facilitate a more active role for PCPs in managing co-morbidities, psychological distress and behavior modification, as well as to overcome communication challenges between physicians not practicing within the same integrated system, are still needed to improve shared cancer care. PMID:21615196
Monsen, Karen A.; Elsbernd, Scott A.; Barnhart, Linda; Stock, Jacquie; Prock, Carla E.; Looman, Wendy S.; Nardella, Maria
2013-01-01
Objectives. To evaluate the feasibility of implementing a statewide children with special health care needs (CSHCN) program evaluation, case management, and surveillance system using a standardized instrument and protocol that operationalized the United States Health and Human Services CSHCN National Performance Measures. Methods. Public health nurses in local public health agencies in Washington State jointly developed and implemented the standardized system. The instrument was the Omaha System. Descriptive statistics were used for the analysis of standardized data. Results. From the sample of CSHCN visit reports (n = 127), 314 problems and 853 interventions were documented. The most common problem identified was growth and development followed by health care supervision, communication with community resources, caretaking/parenting, income, neglect, and abuse. The most common intervention category was surveillance (60%), followed by case management (24%) and teaching, guidance, and counseling (16%). On average, there were 2.7 interventions per problem and 6.7 interventions per visit. Conclusions. This study demonstrates the feasibility of an approach for statewide CSHCN program evaluation, case management, and surveillance system. Knowledge, behavior, and status ratings suggest that there are critical unmet needs in the Washington State CSHCN population for six major problems. PMID:23533804
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoon, Hyunjin; Ansong, Charles; McDermott, Jason E.
Background: Systemic bacterial infections are highly regulated and complex processes that are orchestrated by numerous virulence factors. Genes that are coordinately controlled by the set of regulators required for systemic infection are potentially required for pathogenicity. Results: In this study we present a systems biology approach in which sample-matched multi-omic measurements of fourteen virulence-essential regulator mutants were coupled with computational network analysis to efficiently identify Salmonella virulence factors. Immunoblot experiments verified network-predicted virulence factors and a subset was determined to be secreted into the host cytoplasm, suggesting that they are virulence factors directly interacting with host cellular components. Two ofmore » these, SrfN and PagK2, were required for full mouse virulence and were shown to be translocated independent of either of the type III secretion systems in Salmonella or the type III injectisome-related flagellar mechanism. Conclusions: Integrating multi-omic datasets from Salmonella mutants lacking virulence regulators not only identified novel virulence factors but also defined a new class of translocated effectors involved in pathogenesis. The success of this strategy at discovery of known and novel virulence factors suggests that the approach may have applicability for other bacterial pathogens.« less
2012-01-01
Background Road traffic injuries (RTIs) are among the leading causes of mortality in Vietnam. However, mortality data collection systems in Vietnam in general and for RTIs in particular, remain inconsistent and incomplete. Underlying distributions of external causes and body injuries are not available from routine data collection systems or from studies till date. This paper presents characteristics, user type pattern, seasonal distribution, and causes of 1,061 deaths attributable to road crashes ascertained from a national sample mortality surveillance system in Vietnam over a two-year period (2008 and 2009). Methods A sample mortality surveillance system was designed for Vietnam, comprising 192 communes in 16 provinces, accounting for approximately 3% of the Vietnamese population. Deaths were identified from commune level data sources, and followed up by verbal autopsy (VA) based ascertainment of cause of death. Age-standardised mortality rates from RTIs were computed. VA questionnaires were analysed in depth to derive descriptive characteristics of RTI deaths in the sample. Results The age-standardized mortality rates from RTIs were 33.5 and 8.5 per 100,000 for males and females respectively. Majority of deaths were males (79%). Seventy three percent of all deaths were aged from 15 to 49 years and 58% were motorcycle users. As high as 80% of deaths occurred on the day of injury, 42% occurred prior to arrival at hospital, and a further 29% occurred on-site. Direct causes of death were identified for 446 deaths (42%) with head injuries being the most common cause attributable to road traffic injuries overall (79%) and to motorcycle crashes in particular (78%). Conclusion The VA method can provide a useful data source to analyse RTI mortality. The observed considerable mortality from head injuries among motorcycle users highlights the need to evaluate current practice and effectiveness of motorcycle helmet use in Vietnam. The high number of deaths occurring on-site or prior to hospital admission indicates a need for effective pre-hospital first aid services and timely access to emergency facilities. In the absence of standardised death certification, sustained efforts are needed to strengthen mortality surveillance sites supplemented by VA to support evidence based monitoring and control of RTI mortality. PMID:22838959
The Putative Liquid-Liquid Transition is a Liquid-Solid Transition in Atomistic Models of Water
NASA Astrophysics Data System (ADS)
Chandler, David; Limmer, David
2013-03-01
Our detailed and controlled studies of free energy surfaces for models of water find no evidence for reversible polyamorphism, and a general theoretical analysis of the phase behavior of cold water in nano pores shows that measured behaviors of these systems reflect surface modulation and dynamics of ice, not a liquid-liquid critical point. A few workers reach different conclusions, reporting evidence of a liquid-liquid critical point in computer simulations of supercooled water. In some cases, it appears that these contrary results are based upon simulation algorithms that are inconsistent with principles of statistical mechanics, such as using barostats that do not reproduce the correct distribution of volume fluctuations. In other cases, the results appear to be associated with difficulty equilibrating the supercooled material and mistaking metastability for coarsening of the ordered ice phase. In this case, sufficient information is available for us to reproduce the contrary results and to establish that they are artifacts of finite time sampling. This finding leads us to the conclusion that two distinct, reversible liquid phases do not exist in models of supercooled water.
Ravegnini, Gloria; Sammarini, Giulia; Angelini, Sabrina; Hrelia, Patrizia
2016-07-01
Gastrointestinal stromal tumors (GIST) and chronic myeloid leukemia (CML) are two tumor types deeply different from each other. Despite the differences, these disorders share treatment with tyrosine kinase inhibitor imatinib. Despite the success of imatinib, the response rates vary among different individuals and pharmacogenetics may play an important role in the final clinical outcome. In this review, the authors provide an overview of the pharmacogenetic literature analyzing the role of polymorphisms in both GIST and CML treatment efficacy and toxicity. So far, several polymorphisms influencing the pharmacokinetic determinants of imatinib have been identified. However, the data are not yet conclusive enough to translate pharmacogenetic tests in clinical practice. In this context, the major obstacles to pharmacogenetic test validation are represented by the small sample size of most studies, ethnicity and population admixture as confounding source, and uncertainty related to genetic variants analyzed. In conclusion, a combination of different theoretical approaches, experimental model systems and statistical methods is clearly needed, in order to appreciate pharmacogenetics applied to clinical practice in the near future.
Chevalier, Thérèse M.; Stewart, Garth; Nelson, Monty; McInerney, Robert J.; Brodie, Norman
2016-01-01
It has been well documented that IQ scores calculated using Canadian norms are generally 2–5 points lower than those calculated using American norms on the Wechsler IQ scales. However, recent findings have demonstrated that the difference may be significantly larger for individuals with certain demographic characteristics, and this has prompted discussion about the appropriateness of using the Canadian normative system with a clinical population in Canada. This study compared the interpretive effects of applying the American and Canadian normative systems in a clinical sample. We used a multivariate analysis of variance (ANOVA) to calculate differences between IQ and Index scores in a clinical sample, and mixed model ANOVAs to assess the pattern of differences across age and ability level. As expected, Full Scale IQ scores calculated using Canadian norms were systematically lower than those calculated using American norms, but differences were significantly larger for individuals classified as having extremely low or borderline intellectual functioning when compared with those who scored in the average range. Implications of clinically different conclusions for up to 52.8% of patients based on these discrepancies highlight a unique dilemma facing Canadian clinicians, and underscore the need for caution when choosing a normative system with which to interpret WAIS-IV results in the context of a neuropsychological test battery in Canada. Based on these findings, we offer guidelines for best practice for Canadian clinicians when interpreting data from neuropsychological test batteries that include different normative systems, and suggestions to assist with future test development. PMID:27246955
López-Coronado, Miguel; Vaca, Cesar; Aguado, Jesús Saez; de Castro, Carlos
2015-01-01
Abstract Objective: A systematic review of cost-utility and cost-effectiveness research works of telemedicine, electronic health (e-health), and mobile health (m-health) systems in the literature is presented. Materials and Methods: Academic databases and systems such as PubMed, Scopus, ISI Web of Science, and IEEE Xplore were searched, using different combinations of terms such as “cost-utility” OR “cost utility” AND “telemedicine,” “cost-effectiveness” OR “cost effectiveness” AND “mobile health,” etc. In the articles searched, there were no limitations in the publication date. Results: The search identified 35 relevant works. Many of the articles were reviews of different studies. Seventy-nine percent concerned the cost-effectiveness of telemedicine systems in different specialties such as teleophthalmology, telecardiology, teledermatology, etc. More articles were found between 2000 and 2013. Cost-utility studies were done only for telemedicine systems. Conclusions: There are few cost-utility and cost-effectiveness studies for e-health and m-health systems in the literature. Some cost-effectiveness studies demonstrate that telemedicine can reduce the costs, but not all. Among the main limitations of the economic evaluations of telemedicine systems are the lack of randomized control trials, small sample sizes, and the absence of quality data and appropriate measures. PMID:25474190