Hawker, Charles D; McCarthy, William; Cleveland, David; Messinger, Bonnie L
2014-03-01
Mislabeled samples are a serious problem in most clinical laboratories. Published error rates range from 0.39/1000 to as high as 1.12%. Standardization of bar codes and label formats has not yet achieved the needed improvement. The mislabel rate in our laboratory, although low compared with published rates, prompted us to seek a solution to achieve zero errors. To reduce or eliminate our mislabeled samples, we invented an automated device using 4 cameras to photograph the outside of a sample tube. The system uses optical character recognition (OCR) to look for discrepancies between the patient name in our laboratory information system (LIS) vs the patient name on the customer label. All discrepancies detected by the system's software then require human inspection. The system was installed on our automated track and validated with production samples. We obtained 1 009 830 images during the validation period, and every image was reviewed. OCR passed approximately 75% of the samples, and no mislabeled samples were passed. The 25% failed by the system included 121 samples actually mislabeled by patient name and 148 samples with spelling discrepancies between the patient name on the customer label and the patient name in our LIS. Only 71 of the 121 mislabeled samples detected by OCR were found through our normal quality assurance process. We have invented an automated camera system that uses OCR technology to identify potential mislabeled samples. We have validated this system using samples transported on our automated track. Full implementation of this technology offers the possibility of zero mislabeled samples in the preanalytic stage.
A Short Measure of the Revised Reinforcement Sensitivity Theory - RSQ17.
Čolović, Petar; Smederevac, Snežana; Oljača, Milan; Nikolašević, Željka; Mitrović, Dušanka
2018-04-03
The need for a research and practical tool, such as a short, reliable, and valid personality assessment test, suggests researchers to create shortened versions of original instruments. Reinforcement sensitivity questionnaire (RSQ) was created in line with some basic premises of revised Reinforcement sensitivity theory, which proposes three motivational and emotional systems: Behavioral inhibition system (BIS), responsible for scanning environment for potential threats, Behavioral activation system (BAS), responsible for aproaching behavior, and the Fight/Flight/Freeze system (FFFS), responsible for behavior in the present threat. RSQ comprises five scales: BIS, BAS, Fight, Flight, and Freeze. The aim of this study was to develop a short version of RSQ, which would be beneficial to both research and practical purposes. Item response theory analyses were used for item selection. The study comprised two samples of participants, whereby Sample 1 (N = 837, 34.6% male, aged 18 - 82, M = 31.63, SD = 13.54) served as the derivation sample, while Sample 2 (818 participants, 43.6% male, 18-75 years, M = 29.65, SD = 12.52) served as validation sample. Factorial validity of the short RSQ was examined on both Sample 1 and Sample 2. Convergent and divergent validity of the short RSQ was examined using RST-PQ, Jackson-5, BIS/BAS scales, and Big Five Inventory. The results point to satisfactory internal consistency, factorial validity, and construct validity of the short RSQ, suggesting that it is an adequate measure for research settings or other contexts which require the use of short personality questionnaires.
Validating a biometric authentication system: sample size requirements.
Dass, Sarat C; Zhu, Yongfang; Jain, Anil K
2006-12-01
Authentication systems based on biometric features (e.g., fingerprint impressions, iris scans, human face images, etc.) are increasingly gaining widespread use and popularity. Often, vendors and owners of these commercial biometric systems claim impressive performance that is estimated based on some proprietary data. In such situations, there is a need to independently validate the claimed performance levels. System performance is typically evaluated by collecting biometric templates from n different subjects, and for convenience, acquiring multiple instances of the biometric for each of the n subjects. Very little work has been done in 1) constructing confidence regions based on the ROC curve for validating the claimed performance levels and 2) determining the required number of biometric samples needed to establish confidence regions of prespecified width for the ROC curve. To simplify the analysis that address these two problems, several previous studies have assumed that multiple acquisitions of the biometric entity are statistically independent. This assumption is too restrictive and is generally not valid. We have developed a validation technique based on multivariate copula models for correlated biometric acquisitions. Based on the same model, we also determine the minimum number of samples required to achieve confidence bands of desired width for the ROC curve. We illustrate the estimation of the confidence bands as well as the required number of biometric samples using a fingerprint matching system that is applied on samples collected from a small population.
ERIC Educational Resources Information Center
Omizo, Michael M.; And Others
1983-01-01
Construct validity data found some support for the California Occupational Preference System constructs when its results were evaluated on a sample of 213 female undergraduates relative to the Vocational Preference Inventory results. (PN)
Crouse, Cecelia A; Yeung, Stephanie; Greenspoon, Susan; McGuckian, Amy; Sikorsky, Julie; Ban, Jeff; Mathies, Richard
2005-08-01
To present validation studies performed for the implementation of existing and new technologies to increase the efficiency in the forensic DNA Section of the Palm Beach County Sheriff's Office (PBSO) Crime Laboratory. Using federally funded grants, internal support, and an external Process Mapping Team, the PBSO collaborated with forensic vendors, universities, and other forensic laboratories to enhance DNA testing procedures, including validation of the DNA IQ magnetic bead extraction system, robotic DNA extraction using the BioMek2000, the ABI7000 Sequence Detection System, and is currently evaluating a micro Capillary Array Electrophoresis device. The PBSO successfully validated and implemented both manual and automated Promega DNA IQ magnetic bead extractions system, which have increased DNA profile results from samples with low DNA template concentrations. The Beckman BioMek2000 DNA robotic workstation has been validated for blood, tissue, bone, hair, epithelial cells (touch evidence), and mixed stains such as semen. There has been a dramatic increase in the number of samples tested per case since implementation of the robotic extraction protocols. The validation of the ABI7000 real-time quantitative polymerase chain reaction (qPCR) technology and the single multiplex short tandem repeat (STR) PowerPlex16 BIO amplification system has provided both a time and a financial benefit. In addition, the qPCR system allows more accurate DNA concentration data and the PowerPlex 16 BIO multiplex generates DNA profiles data in half the time when compared to PowerPlex1.1 and PowerPlex2.1 STR systems. The PBSO's future efficiency requirements are being addressed through collaboration with the University of California at Berkeley and the Virginia Division of Forensic Science to validate microcapillary array electrophoresis instrumentation. Initial data demonstrated the electrophoresis of 96 samples in less than twenty minutes. The PBSO demonstrated, through the validation of more efficient extraction and quantification technology, an increase in the number of evidence samples tested using robotic/DNA IQ magnetic bead DNA extraction, a decrease in the number of negative samples amplified due to qPCR and implementation of a single multiplex amplification system. In addition, initial studies show the microcapillary array electrophoresis device (microCAE) evaluation results provide greater sensitivity and faster STR analysis output than current platforms.
Design and validation of a wind tunnel system for odour sampling on liquid area sources.
Capelli, L; Sironi, S; Del Rosso, R; Céntola, P
2009-01-01
The aim of this study is to describe the methods adopted for the design and the experimental validation of a wind tunnel, a sampling system suitable for the collection of gaseous samples on passive area sources, which allows to simulate wind action on the surface to be monitored. The first step of the work was the study of the air velocity profiles. The second step of the work consisted in the validation of the sampling system. For this purpose, the odour concentration of some air samples collected by means of the wind tunnel was measured by dynamic olfactometry. The results of the air velocity measurements show that the wind tunnel design features enabled the achievement of a uniform and homogeneous air flow through the hood. Moreover, the laboratory tests showed a very good correspondence between the odour concentration values measured at the wind tunnel outlet and the odour concentration values predicted by the application of a specific volatilization model, based on the Prandtl boundary layer theory. The agreement between experimental and theoretical trends demonstrate that the studied wind tunnel represents a suitable sampling system for the simulation of specific odour emission rates from liquid area sources without outward flow.
ERIC Educational Resources Information Center
Santelices, Maria Veronica; Taut, Sandy
2011-01-01
This paper describes convergent validity evidence regarding the mandatory, standards-based Chilean national teacher evaluation system (NTES). The study examined whether NTES identifies--and thereby rewards or punishes--the "right" teachers as high- or low-performing. We collected in-depth teaching performance data on a sample of 58…
Broderick, Joan E.; Schneider, Stefan; Junghaenel, Doerte U.; Schwartz, Joseph E.; Stone, Arthur A.
2013-01-01
Objective Evaluation of known group validity, ecological validity, and test-retest reliability of four domain instruments from the Patient Reported Outcomes Measurement System (PROMIS) in osteoarthritis (OA) patients. Methods Recruitment of an osteoarthritis sample and a comparison general population (GP) through an Internet survey panel. Pain intensity, pain interference, physical functioning, and fatigue were assessed for 4 consecutive weeks with PROMIS short forms on a daily basis and compared with same-domain Computer Adaptive Test (CAT) instruments that use a 7-day recall. Known group validity (comparison of OA and GP), ecological validity (comparison of aggregated daily measures with CATs), and test-retest reliability were evaluated. Results The recruited samples matched (age, sex, race, ethnicity) the demographic characteristics of the U.S. sample for arthritis and the 2009 Census for the GP. Compliance with repeated measurements was excellent: > 95%. Known group validity for CATs was demonstrated with large effect sizes (pain intensity: 1.42, pain interference: 1.25, and fatigue: .85). Ecological validity was also established through high correlations between aggregated daily measures and weekly CATs (≥ .86). Test-retest validity (7-day) was very good (≥ .80). Conclusion PROMIS CAT instruments demonstrated known group and ecological validity in a comparison of osteoarthritis patients with a general population sample. Adequate test-retest reliability was also observed. These data provide encouraging initial data on the utility of these PROMIS instruments for clinical and research outcomes in osteoarthritis patients. PMID:23592494
Developmental validation of the PowerPlex(®) Fusion 6C System.
Ensenberger, Martin G; Lenz, Kristy A; Matthies, Learden K; Hadinoto, Gregory M; Schienman, John E; Przech, Angela J; Morganti, Michael W; Renstrom, Daniel T; Baker, Victoria M; Gawrys, Kori M; Hoogendoorn, Marlijn; Steffen, Carolyn R; Martín, Pablo; Alonso, Antonio; Olson, Hope R; Sprecher, Cynthia J; Storts, Douglas R
2016-03-01
The PowerPlex(®) Fusion 6C System is a 27-locus, six-dye, multiplex that includes all markers in the expanded CODIS core loci and increases overlap with STR database standards throughout the world. Additionally, it contains two, rapidly mutating, Y-STRs and is capable of both casework and database workflows, including direct amplification. A multi-laboratory developmental validation study was performed on the PowerPlex(®) Fusion 6C System. Here, we report the results of that study which followed SWGDAM guidelines and includes data for: species specificity, sensitivity, stability, precision, reproducibility and repeatability, case-type samples, concordance, stutter, DNA mixtures, and PCR-based procedures. Where appropriate we report data from both extracted DNA samples and direct amplification samples from various substrates and collection devices. Samples from all studies were separated on both Applied Biosystems 3500 series and 6-dye capable 3130 series Genetic Analyzers and data is reported for each. Together, the data validate the design and demonstrate the performance of the PowerPlex(®) Fusion 6C System. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Della Manna, Angelo; Nye, Jeffrey V; Carney, Christopher; Hammons, Jennifer S; Mann, Michael; Al Shamali, Farida; Vallone, Peter M; Romsos, Erica L; Marne, Beth Ann; Tan, Eugene; Turingan, Rosemary S; Hogan, Catherine; Selden, Richard F; French, Julie L
2016-11-01
Since the implementation of forensic DNA typing in labs more than 20 years ago, the analysis procedures and data interpretation have always been conducted in a laboratory by highly trained and qualified scientific personnel. Rapid DNA technology has the potential to expand testing capabilities within forensic laboratories and to allow forensic STR analysis to be performed outside the physical boundaries of the traditional laboratory. The developmental validation of the DNAscan/ANDE Rapid DNA Analysis System was completed using a BioChipSet™ Cassette consumable designed for high DNA content samples, such as single source buccal swabs. A total of eight laboratories participated in the testing which totaled over 2300 swabs, and included nearly 1400 unique individuals. The goal of this extensive study was to obtain, document, analyze, and assess DNAscan and its internal Expert System to reliably genotype reference samples in a manner compliant with the FBI's Quality Assurance Standards (QAS) and the NDIS Operational Procedures. The DNAscan System provided high quality, concordant results for reference buccal swabs, including automated data analysis with an integrated Expert System. Seven external laboratories and NetBio, the developer of the technology, participated in the validation testing demonstrating the reproducibility and reliability of the system and its successful use in a variety of settings by numerous operators. The DNAscan System demonstrated limited cross reactivity with other species, was resilient in the presence of numerous inhibitors, and provided reproducible results for both buccal and purified DNA samples with sensitivity at a level appropriate for buccal swabs. The precision and resolution of the system met industry standards for detection of micro-variants and displayed single base resolution. PCR-based studies provided confidence that the system was robust and that the amplification reaction had been optimized to provide high quality results. The DNAscan integrated Expert System was examined as part of the Developmental Validation and successfully interpreted the over 2000 samples tested with over 99.998% concordant alleles. The system appropriately flagged samples for human review and failed both mixed samples and samples with insufficient genetic information. These results demonstrated the integrated Expert System makes correct allele calls without human intervention. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Improvement of Simulation Method in Validation of Software of the Coordinate Measuring Systems
NASA Astrophysics Data System (ADS)
Nieciąg, Halina
2015-10-01
Software is used in order to accomplish various tasks at each stage of the functioning of modern measuring systems. Before metrological confirmation of measuring equipment, the system has to be validated. This paper discusses the method for conducting validation studies of a fragment of software to calculate the values of measurands. Due to the number and nature of the variables affecting the coordinate measurement results and the complex character and multi-dimensionality of measurands, the study used the Monte Carlo method of numerical simulation. The article presents an attempt of possible improvement of results obtained by classic Monte Carlo tools. The algorithm LHS (Latin Hypercube Sampling) was implemented as alternative to the simple sampling schema of classic algorithm.
Environmental Validation of Legionella Control in a VHA Facility Water System.
Jinadatha, Chetan; Stock, Eileen M; Miller, Steve E; McCoy, William F
2018-03-01
OBJECTIVES We conducted this study to determine what sample volume, concentration, and limit of detection (LOD) are adequate for environmental validation of Legionella control. We also sought to determine whether time required to obtain culture results can be reduced compared to spread-plate culture method. We also assessed whether polymerase chain reaction (PCR) and in-field total heterotrophic aerobic bacteria (THAB) counts are reliable indicators of Legionella in water samples from buildings. DESIGN Comparative Legionella screening and diagnostics study for environmental validation of a healthcare building water system. SETTING Veterans Health Administration (VHA) facility water system in central Texas. METHODS We analyzed 50 water samples (26 hot, 24 cold) from 40 sinks and 10 showers using spread-plate cultures (International Standards Organization [ISO] 11731) on samples shipped overnight to the analytical lab. In-field, on-site cultures were obtained using the PVT (Phigenics Validation Test) culture dipslide-format sampler. A PCR assay for genus-level Legionella was performed on every sample. RESULTS No practical differences regardless of sample volume filtered were observed. Larger sample volumes yielded more detections of Legionella. No statistically significant differences at the 1 colony-forming unit (CFU)/mL or 10 CFU/mL LOD were observed. Approximately 75% less time was required when cultures were started in the field. The PCR results provided an early warning, which was confirmed by spread-plate cultures. The THAB results did not correlate with Legionella status. CONCLUSIONS For environmental validation at this facility, we confirmed that (1) 100 mL sample volumes were adequate, (2) 10× concentrations were adequate, (3) 10 CFU/mL LOD was adequate, (4) in-field cultures reliably reduced time to get results by 75%, (5) PCR provided a reliable early warning, and (6) THAB was not predictive of Legionella results. Infect Control Hosp Epidemiol 2018;39:259-266.
NASA Astrophysics Data System (ADS)
Chan, S.; Lehnert, K. A.; Coleman, R. J.
2011-12-01
SESAR, the System for Earth Sample Registration, is an online registry for physical samples collected for Earth and environmental studies. SESAR generates and administers the International Geo Sample Number IGSN, a unique identifier for samples that is dramatically advancing interoperability amongst information systems for sample-based data. SESAR was developed to provide the complete range of registry services, including definition of IGSN syntax and metadata profiles, registration and validation of name spaces requested by users, tools for users to submit and manage sample metadata, validation of submitted metadata, generation and validation of the unique identifiers, archiving of sample metadata, and public or private access to the sample metadata catalog. With the development of SESAR v3, we placed particular emphasis on creating enhanced tools that make metadata submission easier and more efficient for users, and that provide superior functionality for users to manage metadata of their samples in their private workspace MySESAR. For example, SESAR v3 includes a module where users can generate custom spreadsheet templates to enter metadata for their samples, then upload these templates online for sample registration. Once the content of the template is uploaded, it is displayed online in an editable grid format. Validation rules are executed in real-time on the grid data to ensure data integrity. Other new features of SESAR v3 include the capability to transfer ownership of samples to other SESAR users, the ability to upload and store images and other files in a sample metadata profile, and the tracking of changes to sample metadata profiles. In the next version of SESAR (v3.5), we will further improve the discovery, sharing, registration of samples. For example, we are developing a more comprehensive suite of web services that will allow discovery and registration access to SESAR from external systems. Both batch and individual registrations will be possible through web services. Based on valuable feedback from the user community, we will introduce enhancements that add greater flexibility to the system to accommodate the vast diversity of metadata that users want to store. Users will be able to create custom metadata fields and use these for the samples they register. Users will also be able to group samples into 'collections' to make retrieval for research projects or publications easier. An improved interface design will allow for better workflow transition and navigation throughout the application. In keeping up with the demands of a growing community, SESAR has also made process changes to ensure efficiency in system development. For example, we have implemented a release cycle to better track enhancements and fixes to the system, and an API library that facilitates reusability of code. Usage tracking, metrics and surveys capture information to guide the direction of future developments. A new set of administrative tools allows greater control of system management.
NASA Technical Reports Server (NTRS)
Sams, Clarence; Crucian, Brian; Stowe, Raymond; Pierson, Duane; Mehta, Satish; Morukov, Boris; Uchakin, Peter; Nehlsen-Cannarella, Sandra
2008-01-01
Validation of Procedures for Monitoring Crew Member Immune Function - Short Duration Biological Investigation (Integrated Immune-SDBI) will assess the clinical risks resulting from the adverse effects of space flight on the human immune system and will validate a flightcompatible immune monitoring strategy. Immune system changes will be monitored by collecting and analyzing blood, urine and saliva samples from crewmembers before, during and after space flight.
Mars Ascent Vehicle Test Requirements and Terrestrial Validation
NASA Technical Reports Server (NTRS)
Dankanich, John W.; Cathey, Henry M.; Smith, David A.
2011-01-01
The Mars robotic sample return mission has been a potential flagship mission for NASA s science mission directorate for decades. The Mars Exploration Program and the planetary science decadal survey have highlighted both the science return of the Mars Sample Return mission, but also the need for risk reduction through technology development. One of the critical elements of the MSR mission is the Mars Ascent Vehicle, which must launch the sample from the surface of Mars and place it into low Mars orbit. The MAV has significant challenges to overcome due to the Martian environments and the Entry Descent and Landing system constraints. Launch vehicles typically have a relatively low success probability for early flights, and a thorough system level validation is warranted. The MAV flight environments are challenging and in some cases impossible to replicate terrestrially. The expected MAV environments have been evaluated and a first look of potential system test options has been explored. The terrestrial flight requirements and potential validation options are presented herein.
A demonstration of NIOSH push-pull ventilation criteria.
Klein, M K
1987-03-01
This paper summarizes the results of a study performed on an actual chrome plating tank in order to validate criteria for push-pull ventilation systems developed by Huebener and Hughes at NIOSH. Validation of the criteria was made by taking area industrial hygiene samples for hexavalent and total chrome at ten locations around the plating tank. The sampling was performed during actual production runs or while the tank was operating with a dummy load. The sampling data are summarized. The data show that the push-pull system, operating at Huebener's criteria, could control emissions to below the current standards and guidelines. Conclusions and recommendations are included.
ERIC Educational Resources Information Center
Kettler, Ryan J.; Elliott, Stephen N.; Davies, Michael; Griffin, Patrick
2012-01-01
This study addresses the predictive validity of results from a screening system of academic enablers, with a sample of Australian elementary school students, when the criterion variable is end-of-year achievement. The investigation included (a) comparing the predictive validity of a brief criterion-referenced nomination system with more…
Geographic Information Systems to Assess External Validity in Randomized Trials.
Savoca, Margaret R; Ludwig, David A; Jones, Stedman T; Jason Clodfelter, K; Sloop, Joseph B; Bollhalter, Linda Y; Bertoni, Alain G
2017-08-01
To support claims that RCTs can reduce health disparities (i.e., are translational), it is imperative that methodologies exist to evaluate the tenability of external validity in RCTs when probabilistic sampling of participants is not employed. Typically, attempts at establishing post hoc external validity are limited to a few comparisons across convenience variables, which must be available in both sample and population. A Type 2 diabetes RCT was used as an example of a method that uses a geographic information system to assess external validity in the absence of a priori probabilistic community-wide diabetes risk sampling strategy. A geographic information system, 2009-2013 county death certificate records, and 2013-2014 electronic medical records were used to identify community-wide diabetes prevalence. Color-coded diabetes density maps provided visual representation of these densities. Chi-square goodness of fit statistic/analysis tested the degree to which distribution of RCT participants varied across density classes compared to what would be expected, given simple random sampling of the county population. Analyses were conducted in 2016. Diabetes prevalence areas as represented by death certificate and electronic medical records were distributed similarly. The simple random sample model was not a good fit for death certificate record (chi-square, 17.63; p=0.0001) and electronic medical record data (chi-square, 28.92; p<0.0001). Generally, RCT participants were oversampled in high-diabetes density areas. Location is a highly reliable "principal variable" associated with health disparities. It serves as a directly measurable proxy for high-risk underserved communities, thus offering an effective and practical approach for examining external validity of RCTs. Copyright © 2017 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.
Zhang, Jie; Wei, Shimin; Ayres, David W; Smith, Harold T; Tse, Francis L S
2011-09-01
Although it is well known that automation can provide significant improvement in the efficiency of biological sample preparation in quantitative LC-MS/MS analysis, it has not been widely implemented in bioanalytical laboratories throughout the industry. This can be attributed to the lack of a sound strategy and practical procedures in working with robotic liquid-handling systems. Several comprehensive automation assisted procedures for biological sample preparation and method validation were developed and qualified using two types of Hamilton Microlab liquid-handling robots. The procedures developed were generic, user-friendly and covered the majority of steps involved in routine sample preparation and method validation. Generic automation procedures were established as a practical approach to widely implement automation into the routine bioanalysis of samples in support of drug-development programs.
Shackleton, David; Pagram, Jenny; Ives, Lesley; Vanhinsbergh, Des
2018-06-02
The RapidHIT™ 200 System is a fully automated sample-to-DNA profile system designed to produce high quality DNA profiles within 2h. The use of RapidHIT™ 200 System within the United Kingdom Criminal Justice System (UKCJS) has required extensive development and validation of methods with a focus on AmpFℓSTR ® NGMSElect™ Express PCR kit to comply with specific regulations for loading to the UK National DNA Database (NDNAD). These studies have been carried out using single source reference samples to simulate live reference samples taken from arrestees and victims for elimination. The studies have shown that the system is capable of generating high quality profile and has achieved the accreditations necessary to load to the NDNAD; a first for the UK. Copyright © 2018 Elsevier B.V. All rights reserved.
TOISHI, Yuko; TSUNODA, Nobuo; NAGATA, Shun-ichi; KIRISAWA, Rikio; NAGAOKA, Kentaro; WATANABE, Gen; YANAGAWA, Yojiro; KATAGIRI, Seiji; TAYA, Kazuyoshi
2017-01-01
Testosterone (T) concentration is a useful indicator of reproductive function in male animals. However, T concentration is not usually measured in veterinary clinics, partly due to the unavailability of reliable and rapid assays for animal samples. In this study, a rapid chemiluminescent enzyme immunoassay system (CLEIA system) that was developed for the measurement of T concentration in humans use was validated for stallion blood samples. First, serum T concentrations were measured using the CLEIA system and compared with those measured by a fluoroimmunoassay that has been validated for use in stallions. The serum T concentrations measured by the two methods were highly correlated (r = 0.9865, n = 56). Second, to validate the use of whole blood as assay samples, T concentrations in whole blood and in the serum were measured by the CLEIA system. T concentrations in both samples were highly correlated (r = 0.9665, n = 64). Finally, to evaluate the practical value of the CLEIA system in clinical settings, T concentrations were measured in three stallions with reproductive abnormalities after the administration of human chorionic gonadotropin (hCG). Two stallions with small or absent testes in the scrotum showed an increase in T production in response to hCG administration and one stallion with seminoma did not. In conclusion, the CLEIA system was found to be a rapid and reliable tool for measuring T concentrations in stallions and may improve reproductive management in clinical settings and in breeding studs. PMID:29129877
Validation Test Results for Orthogonal Probe Eddy Current Thruster Inspection System
NASA Technical Reports Server (NTRS)
Wincheski, Russell A.
2007-01-01
Recent nondestructive evaluation efforts within NASA have focused on an inspection system for the detection of intergranular cracking originating in the relief radius of Primary Reaction Control System (PCRS) Thrusters. Of particular concern is deep cracking in this area which could lead to combustion leakage in the event of through wall cracking from the relief radius into an acoustic cavity of the combustion chamber. In order to reliably detect such defects while ensuring minimal false positives during inspection, the Orthogonal Probe Eddy Current (OPEC) system has been developed and an extensive validation study performed. This report describes the validation procedure, sample set, and inspection results as well as comparing validation flaws with the response from naturally occuring damage.
Anderson, Ruth A.; Hsieh, Pi-Ching; Su, Hui Fang; Landerman, Lawrence R.; McDaniel, Reuben R.
2013-01-01
Objectives. To (1) describe participation in decision-making as a systems-level property of complex adaptive systems and (2) present empirical evidence of reliability and validity of a corresponding measure. Method. Study 1 was a mail survey of a single respondent (administrators or directors of nursing) in each of 197 nursing homes. Study 2 was a field study using random, proportionally stratified sampling procedure that included 195 organizations with 3,968 respondents. Analysis. In Study 1, we analyzed the data to reduce the number of scale items and establish initial reliability and validity. In Study 2, we strengthened the psychometric test using a large sample. Results. Results demonstrated validity and reliability of the participation in decision-making instrument (PDMI) while measuring participation of workers in two distinct job categories (RNs and CNAs). We established reliability at the organizational level aggregated items scores. We established validity of the multidimensional properties using convergent and discriminant validity and confirmatory factor analysis. Conclusions. Participation in decision making, when modeled as a systems-level property of organization, has multiple dimensions and is more complex than is being traditionally measured. Managers can use this model to form decision teams that maximize the depth and breadth of expertise needed and to foster connection among them. PMID:24349771
Anderson, Ruth A; Plowman, Donde; Corazzini, Kirsten; Hsieh, Pi-Ching; Su, Hui Fang; Landerman, Lawrence R; McDaniel, Reuben R
2013-01-01
Objectives. To (1) describe participation in decision-making as a systems-level property of complex adaptive systems and (2) present empirical evidence of reliability and validity of a corresponding measure. Method. Study 1 was a mail survey of a single respondent (administrators or directors of nursing) in each of 197 nursing homes. Study 2 was a field study using random, proportionally stratified sampling procedure that included 195 organizations with 3,968 respondents. Analysis. In Study 1, we analyzed the data to reduce the number of scale items and establish initial reliability and validity. In Study 2, we strengthened the psychometric test using a large sample. Results. Results demonstrated validity and reliability of the participation in decision-making instrument (PDMI) while measuring participation of workers in two distinct job categories (RNs and CNAs). We established reliability at the organizational level aggregated items scores. We established validity of the multidimensional properties using convergent and discriminant validity and confirmatory factor analysis. Conclusions. Participation in decision making, when modeled as a systems-level property of organization, has multiple dimensions and is more complex than is being traditionally measured. Managers can use this model to form decision teams that maximize the depth and breadth of expertise needed and to foster connection among them.
Validation of a multiplex electrochemiluminescent immunoassay platform in human and mouse samples
Bastarache, J.A.; Koyama, T.; Wickersham, N.E; Ware, L.B.
2014-01-01
Despite the widespread use of multiplex immunoassays, there are very few scientific reports that test the accuracy and reliability of a platform prior to publication of experimental data. Our laboratory has previously demonstrated the need for new assay platform validation prior to use of biologic samples from large studies in order to optimize sample handling and assay performance. In this study, our goal was to test the accuracy and reproducibility of an electrochemiluminescent multiplex immunoassay platform (Meso Scale Discovery, MSD®) and compare this platform to validated, singleplex immunoassays (R&D Systems®) using actual study subject (human plasma and mouse bronchoalveolar lavage fluid (BALF) and plasma) samples. We found that the MSD platform performed well on intra- and inter-assay comparisons, spike and recovery and cross-platform comparisons. The mean intra-assay CV% and range for MSD was 3.49 (0.0-10.4) for IL-6 and 2.04 (0.1-7.9) for IL-8. The correlation between values for identical samples measured on both MSD and R&D was R=0.97 for both analytes. The mouse MSD assay had a broader range of CV% with means ranging from 9.5-28.5 depending on the analyte. The range of mean CV% was similar for single plex ELISAs at 4.3-23.7 depending on the analyte. Regardless of species or sample type, CV% was more variable at lower protein concentrations. In conclusion, we validated a multiplex electrochemiluminscent assay system and found that it has superior test characteristics in human plasma compared to mouse BALF and plasma. Both human and MSD assays compared favorably to well-validated singleplex ELISA's PMID:24768796
Automation and validation of DNA-banking systems.
Thornton, Melissa; Gladwin, Amanda; Payne, Robin; Moore, Rachael; Cresswell, Carl; McKechnie, Douglas; Kelly, Steve; March, Ruth
2005-10-15
DNA banking is one of the central capabilities on which modern genetic research rests. The DNA-banking system plays an essential role in the flow of genetic data from patients and genetics researchers to the application of genetic research in the clinic. Until relatively recently, large collections of DNA samples were not common in human genetics. Now, collections of hundreds of thousands of samples are common in academic institutions and private companies. Automation of DNA banking can dramatically increase throughput, eliminate manual errors and improve the productivity of genetics research. An increased emphasis on pharmacogenetics and personalized medicine has highlighted the need for genetics laboratories to operate within the principles of a recognized quality system such as good laboratory practice (GLP). Automated systems are suitable for such laboratories but require a level of validation that might be unfamiliar to many genetics researchers. In this article, we use the AstraZeneca automated DNA archive and reformatting system (DART) as a case study of how such a system can be successfully developed and validated within the principles of GLP.
A simple risk scoring system for prediction of relapse after inpatient alcohol treatment.
Pedersen, Mads Uffe; Hesse, Morten
2009-01-01
Predicting relapse after alcoholism treatment can be useful in targeting patients for aftercare services. However, a valid and practical instrument for predicting relapse risk does not exist. Based on a prospective study of alcoholism treatment, we developed the Risk of Alcoholic Relapse Scale (RARS) using items taken from the Addiction Severity Index and some basic demographic information. The RARS was cross-validated using two non-overlapping samples, and tested for its ability to predict relapse across different models of treatment. The RARS predicted relapse to drinking within 6 months after alcoholism treatment in both the original and the validation sample, and in a second validation sample it predicted admission to new treatment 3 years after treatment. The RARS can identify patients at high risk of relapse who need extra aftercare and support after treatment.
Braido, Fulvio; Santus, Pierachille; Corsico, Angelo Guido; Di Marco, Fabiano; Melioli, Giovanni; Scichilone, Nicola; Solidoro, Paolo
2018-01-01
The purposes of this study were development and validation of an expert system (ES) aimed at supporting the diagnosis of chronic obstructive lung disease (COLD). A questionnaire and a WebFlex code were developed and validated in silico. An expert panel pilot validation on 60 cases and a clinical validation on 241 cases were performed. The developed questionnaire and code validated in silico resulted in a suitable tool to support the medical diagnosis. The clinical validation of the ES was performed in an academic setting that included six different reference centers for respiratory diseases. The results of the ES expressed as a score associated with the risk of suffering from COLD were matched and compared with the final clinical diagnoses. A set of 60 patients were evaluated by a pilot expert panel validation with the aim of calculating the sample size for the clinical validation study. The concordance analysis between these preliminary ES scores and diagnoses performed by the experts indicated that the accuracy was 94.7% when both experts and the system confirmed the COLD diagnosis and 86.3% when COLD was excluded. Based on these results, the sample size of the validation set was established in 240 patients. The clinical validation, performed on 241 patients, resulted in ES accuracy of 97.5%, with confirmed COLD diagnosis in 53.6% of the cases and excluded COLD diagnosis in 32% of the cases. In 11.2% of cases, a diagnosis of COLD was made by the experts, although the imaging results showed a potential concomitant disorder. The ES presented here (COLD ES ) is a safe and robust supporting tool for COLD diagnosis in primary care settings.
ERIC Educational Resources Information Center
Weis, Robert; Smenner, Lindsey
2007-01-01
The authors investigate the construct validity of the Behavior Assessment System for Children Self-Report of Personality (BASC-SRP; Reynolds & Kamphaus, 1998). A sample of 970 adolescents (16-18 years) with histories of disruptive behavior problems and truancy complete the SRP; a subsample of 290 adolescents also completed the Minnesota…
NASA Technical Reports Server (NTRS)
Generazio, Edward R. (Inventor)
2012-01-01
A method of validating a probability of detection (POD) testing system using directed design of experiments (DOE) includes recording an input data set of observed hit and miss or analog data for sample components as a function of size of a flaw in the components. The method also includes processing the input data set to generate an output data set having an optimal class width, assigning a case number to the output data set, and generating validation instructions based on the assigned case number. An apparatus includes a host machine for receiving the input data set from the testing system and an algorithm for executing DOE to validate the test system. The algorithm applies DOE to the input data set to determine a data set having an optimal class width, assigns a case number to that data set, and generates validation instructions based on the case number.
Development, Validation, and Application of OSSEs at NASA/GMAO
NASA Technical Reports Server (NTRS)
Errico, Ronald; Prive, Nikki
2015-01-01
During the past several years, NASA Goddard's Global Modeling and Assimilation Office (GMAO) has been developing a framework for conducting Observing System Simulation Experiments (OSSEs). The motivation and design of that framework will be described and a sample of validation results presented. Fundamentals issues will be highlighted, particularly the critical importance of appropriately simulating system errors. Some problems that have just arisen in the newest experimental system will also be mentioned.
Pageler, Natalie M; Grazier G'Sell, Max Jacob; Chandler, Warren; Mailes, Emily; Yang, Christine; Longhurst, Christopher A
2016-09-01
The objective of this project was to use statistical techniques to determine the completeness and accuracy of data migrated during electronic health record conversion. Data validation during migration consists of mapped record testing and validation of a sample of the data for completeness and accuracy. We statistically determined a randomized sample size for each data type based on the desired confidence level and error limits. The only error identified in the post go-live period was a failure to migrate some clinical notes, which was unrelated to the validation process. No errors in the migrated data were found during the 12- month post-implementation period. Compared to the typical industry approach, we have demonstrated that a statistical approach to sampling size for data validation can ensure consistent confidence levels while maximizing efficiency of the validation process during a major electronic health record conversion. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Eslami, Ahmad Ali; Amidi Mazaheri, Maryam; Mostafavi, Firoozeh; Abbasi, Mohamad Hadi; Noroozi, Ensieh
2014-01-01
Assessment of social skills is a necessary requirement to develop and evaluate the effectiveness of cognitive and behavioral interventions. This paper reports the cultural adaptation and psychometric properties of the Farsi version of the social skills rating system-secondary students form (SSRS-SS) questionnaire (Gresham and Elliot, 1990), in a normative sample of secondary school students. A two-phase design was used that phase 1 consisted of the linguistic adaptation and in phase 2, using cross-sectional sample survey data, the construct validity and reliability of the Farsi version of the SSRS-SS were examined in a sample of 724 adolescents aged from 13 to 19 years. Content validity index was excellent, and the floor/ceiling effects were low. After deleting five of the original SSRS-SS items, the findings gave support for the item convergent and divergent validity. Factor analysis revealed four subscales. RESULTS showed good internal consistency (0.89) and temporal stability (0.91) for the total scale score. Findings demonstrated support for the use of the 27-item Farsi version in the school setting. Directions for future research regarding the applicability of the scale in other settings and populations of adolescents are discussed.
Air Combat Training: Good Stick Index Validation. Final Report for Period 3 April 1978-1 April 1979.
ERIC Educational Resources Information Center
Moore, Samuel B.; And Others
A study was conducted to investigate and statistically validate a performance measuring system (the Good Stick Index) in the Tactical Air Command Combat Engagement Simulator I (TAC ACES I) Air Combat Maneuvering (ACM) training program. The study utilized a twelve-week sample of eighty-nine student pilots to statistically validate the Good Stick…
Fast Sampling Gas Chromatography (GC) System for Speciation in a Shock Tube
2016-10-31
capture similar ethylene decomposition rates for temperature-dependent shock experiments. (a) Papers published in peer-reviewed journals (N/A for none...3 GC Sampling System Validation Experiments ............................................................................... 5 Ethylene ...results for cold shock experiments, and both techniques capture similar ethylene decomposition rates for temperature-dependent shock experiments. Problem
Martín-Sabroso, Cristina; Tavares-Fernandes, Daniel Filipe; Espada-García, Juan Ignacio; Torres-Suárez, Ana Isabel
2013-12-15
In this work a protocol to validate analytical procedures for the quantification of drug substances formulated in polymeric systems that comprise both drug entrapped into the polymeric matrix (assay:content test) and drug released from the systems (assay:dissolution test) is developed. This protocol is applied to the validation two isocratic HPLC analytical procedures for the analysis of dexamethasone phosphate disodium microparticles for parenteral administration. Preparation of authentic samples and artificially "spiked" and "unspiked" samples is described. Specificity (ability to quantify dexamethasone phosphate disodium in presence of constituents of the dissolution medium and other microparticle constituents), linearity, accuracy and precision are evaluated, in the range from 10 to 50 μg mL(-1) in the assay:content test procedure and from 0.25 to 10 μg mL(-1) in the assay:dissolution test procedure. The robustness of the analytical method to extract drug from microparticles is also assessed. The validation protocol developed allows us to conclude that both analytical methods are suitable for their intended purpose, but the lack of proportionality of the assay:dissolution analytical method should be taken into account. The validation protocol designed in this work could be applied to the validation of any analytical procedure for the quantification of drugs formulated in controlled release polymeric microparticles. Copyright © 2013 Elsevier B.V. All rights reserved.
A tool for developing an automatic insect identification system based on wing outlines
Yang, He-Ping; Ma, Chun-Sen; Wen, Hui; Zhan, Qing-Bin; Wang, Xin-Li
2015-01-01
For some insect groups, wing outline is an important character for species identification. We have constructed a program as the integral part of an automated system to identify insects based on wing outlines (DAIIS). This program includes two main functions: (1) outline digitization and Elliptic Fourier transformation and (2) classifier model training by pattern recognition of support vector machines and model validation. To demonstrate the utility of this program, a sample of 120 owlflies (Neuroptera: Ascalaphidae) was split into training and validation sets. After training, the sample was sorted into seven species using this tool. In five repeated experiments, the mean accuracy for identification of each species ranged from 90% to 98%. The accuracy increased to 99% when the samples were first divided into two groups based on features of their compound eyes. DAIIS can therefore be a useful tool for developing a system of automated insect identification. PMID:26251292
Developmental validation of the PowerPlex(®) ESI 16/17 Fast and PowerPlex(®) ESX 16/17 Fast Systems.
McLaren, Robert S; Bourdeau-Heller, Jeanne; Patel, Jaynish; Thompson, Jonelle M; Pagram, Jenny; Loake, Thomas; Beesley, David; Pirttimaa, Markus; Hill, Carolyn R; Duewer, David L; Kline, Margaret C; Butler, John M; Storts, Douglas R
2014-11-01
The PowerPlex(®) ESI 16 Fast, ESI 17 Fast, ESX 16 Fast, and ESX 17 Fast Systems represent faster cycling versions (50min or less) of the PowerPlex(®) ESI and ESX Systems released by Promega in 2009 to accommodate the ENFSI and EDNAP groups' call for new STR multiplexes for Europe. In addition to amplification of purified DNA samples, these new faster cycling systems allow for direct amplification from single-source blood and buccal samples deposited on FTA(®) and nonFTA paper as well as from SwabSolution™ extracts of buccal swabs without the need for purification and quantitation. There are no changes to the autosomal primer pair sequences in the PowerPlex(®) ESI Fast and ESX Fast Systems compared to the original multiplexes, and full concordance at all autosomal loci and amelogenin was observed with data generated previously with the original PowerPlex(®) ESI and ESX Systems. This paper describes the developmental validation study performed on these new fast systems following guidelines issued by the Scientific Working Group on DNA Analysis Methods (SWGDAM) and those of the DNA Advisory Board (DAB). Validation data demonstrate that these systems are sensitive for detecting low levels of DNA while also being capable of generating robust profiles from the high amount of input DNA present in direct-amplification samples. These systems are also tolerant to both high concentrations of PCR inhibitors as well as to slight variations in the final concentration of master mix and primer pair present in the amplification reaction that might be encountered due to pipetting error. The results of this validation study demonstrate that these systems may be used on multiple thermal cyclers and capillary electrophoresis platforms. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Houssaini, Allal; Assoumou, Lambert; Miller, Veronica; Calvez, Vincent; Marcelin, Anne-Geneviève; Flandre, Philippe
2013-01-01
Background Several attempts have been made to determine HIV-1 resistance from genotype resistance testing. We compare scoring methods for building weighted genotyping scores and commonly used systems to determine whether the virus of a HIV-infected patient is resistant. Methods and Principal Findings Three statistical methods (linear discriminant analysis, support vector machine and logistic regression) are used to determine the weight of mutations involved in HIV resistance. We compared these weighted scores with known interpretation systems (ANRS, REGA and Stanford HIV-db) to classify patients as resistant or not. Our methodology is illustrated on the Forum for Collaborative HIV Research didanosine database (N = 1453). The database was divided into four samples according to the country of enrolment (France, USA/Canada, Italy and Spain/UK/Switzerland). The total sample and the four country-based samples allow external validation (one sample is used to estimate a score and the other samples are used to validate it). We used the observed precision to compare the performance of newly derived scores with other interpretation systems. Our results show that newly derived scores performed better than or similar to existing interpretation systems, even with external validation sets. No difference was found between the three methods investigated. Our analysis identified four new mutations associated with didanosine resistance: D123S, Q207K, H208Y and K223Q. Conclusions We explored the potential of three statistical methods to construct weighted scores for didanosine resistance. Our proposed scores performed at least as well as already existing interpretation systems and previously unrecognized didanosine-resistance associated mutations were identified. This approach could be used for building scores of genotypic resistance to other antiretroviral drugs. PMID:23555613
Instrumentation of sampling aircraft for measurement of launch vehicle effluents
NASA Technical Reports Server (NTRS)
Wornom, D. E.; Woods, D. C.; Thomas, M. E.; Tyson, R. W.
1977-01-01
An aircraft was selected and instrumented to measure effluents emitted from large solid propellant rockets during launch activities. The considerations involved in aircraft selection, sampling probes, and instrumentation are discussed with respect to obtaining valid airborne measurements. Discussions of the data acquisition system used, the instrument power system, and operational sampling procedures are included. Representative measurements obtained from an actual rocket launch monitoring activity are also presented.
Moeller, Stine Bjerrum; Novaco, Raymond W; Heinola-Nielsen, Vivian; Hougaard, Helle
2016-10-01
Anger has high prevalence in clinical and forensic settings, and it is associated with aggressive behavior and ward atmosphere on psychiatric units. Dysregulated anger is a clinical problem in Danish mental health care systems, but no anger assessment instruments have been validated in Danish. Because the Novaco Anger Scale and Provocation Inventory (NAS-PI) has been extensively validated with different clinical populations and lends itself to clinical case formulation, it was selected for translation and evaluation in the present multistudy project. Psychometric properties of the NAS-PI were investigated with samples of 477 nonclinical, 250 clinical, 167 male prisoner, and 64 male forensic participants. Anger prevalence and its relationship with other anger measures, anxiety/depression, and aggression were examined. NAS-PI was found to have high reliability, concurrent validity, and discriminant validity, and its scores discriminated the samples. High scores in the offender group demonstrated the feasibility of obtaining self-report assessments of anger with this population. Retrospective and prospective validity of the NAS were tested with the forensic patient sample regarding physically aggressive behavior in hospital. Regression analyses showed that higher scores on NAS increase the risk of having acted aggressively in the past and of acting aggressively in the future. © The Author(s) 2015.
The validation of forensic DNA extraction systems to utilize soil contaminated biological evidence.
Kasu, Mohaimin; Shires, Karen
2015-07-01
The production of full DNA profiles from biological evidence found in soil has a high failure rate due largely to the inhibitory substance humic acid (HA). Abundant in various natural soils, HA co-extracts with DNA during extraction and inhibits DNA profiling by binding to the molecular components of the genotyping assay. To successfully utilize traces of soil contaminated evidence, such as that found at many murder and rape crime scenes in South Africa, a reliable HA removal extraction system would often be selected based on previous validation studies. However, for many standard forensic DNA extraction systems, peer-reviewed publications detailing the efficacy on soil evidence is either lacking or is incomplete. Consequently, these sample types are often not collected or fail to yield suitable DNA material due to the use of unsuitable methodology. The aim of this study was to validate the common forensic DNA collection and extraction systems used in South Africa, namely DNA IQ, FTA elute and Nucleosave for processing blood and saliva contaminated with HA. A forensic appropriate volume of biological evidence was spiked with HA (0, 0.5, 1.5 and 2.5 mg/ml) and processed through each extraction protocol for the evaluation of HA removal using QPCR and STR-genotyping. The DNA IQ magnetic bead system effectively removed HA from highly contaminated blood and saliva, and generated consistently acceptable STR profiles from both artificially spiked samples and crude soil samples. This system is highly recommended for use on soil-contaminated evidence over the cellulose card-based systems currently being preferentially used for DNA sample collection. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Study on detection geometry and detector shielding for portable PGNAA system using PHITS
NASA Astrophysics Data System (ADS)
Ithnin, H.; Dahing, L. N. S.; Lip, N. M.; Rashid, I. Q. Abd; Mohamad, E. J.
2018-01-01
Prompt gamma-ray neutron activation analysis (PGNAA) measurements require efficient detectors for gamma-ray detection. Apart from experimental studies, the Monte Carlo (MC) method has become one of the most popular tools in detector studies. The absolute efficiency for a 2 × 2 inch cylindrical Sodium Iodide (NaI) detector has been modelled using the PHITS software and compared with previous studies in literature. In the present work, PHITS code is used for optimization of portable PGNAA system using the validated NaI detector. The detection geometry is optimized by moving the detector along the sample to find the highest intensity of the prompt gamma generated from the sample. Shielding material for the validated NaI detector is also studied to find the best option for the PGNAA system setup. The result shows the optimum distance for detector is on the surface of the sample and around 15 cm from the source. The results specify that this process can be followed to determine the best setup for PGNAA system for a different sample size and detector type. It can be concluded that data from PHITS code is a strong tool not only for efficiency studies but also for optimization of PGNAA system.
Tice, George; Andaloro, Bridget; White, H Kirk; Bolton, Lance; Wang, Siqun; Davis, Eugene; Wallace, Morgan
2009-01-01
In 2006, DuPont Qualicon introduced the BAX system Q7 instrument for use with its assays. To demonstrate the equivalence of the new and old instruments, a validation study was conducted using the BAX system PCR Assay for Salmonella, AOAC Official Method 2003.09, on three food types. The foods were simultaneously analyzed with the BAX system Q7 instrument and either the U.S. Food and Drug Administration Bacteriological Analytical Manual or the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook reference method for detecting Salmonella. Comparable performance between the BAX system and the reference methods was observed. Of the 75 paired samples analyzed, 39 samples were positive by both the BAX system and reference methods, and 36 samples were negative by both the BAX system and reference methods, demonstrating 100% correlation. Inclusivity and exclusivity for the BAX system Q7 instrument were also established by testing 50 Salmonella strains and 20 non-Salmonella isolates. All Salmonella strains returned positive results, and all non-Salmonella isolates returned a negative response.
Sauter, Jennifer L; Grogg, Karen L; Vrana, Julie A; Law, Mark E; Halvorson, Jennifer L; Henry, Michael R
2016-02-01
The objective of the current study was to establish a process for validating immunohistochemistry (IHC) protocols for use on the Cellient cell block (CCB) system. Thirty antibodies were initially tested on CCBs using IHC protocols previously validated on formalin-fixed, paraffin-embedded tissue (FFPE). Cytology samples were split to generate thrombin cell blocks (TCB) and CCBs. IHC was performed in parallel. Antibody immunoreactivity was scored, and concordance or discordance in immunoreactivity between the TCBs and CCBs for each sample was determined. Criteria for validation of an antibody were defined as concordant staining in expected positive and negative cells, in at least 5 samples each, and concordance in at least 90% of the samples total. Antibodies that failed initial validation were retested after alterations in IHC conditions. Thirteen of the 30 antibodies (43%) did not meet initial validation criteria. Of those, 8 antibodies (calretinin, clusters of differentiation [CD] 3, CD20, CDX2, cytokeratin 20, estrogen receptor, MOC-31, and p16) were optimized for CCBs and subsequently validated. Despite several alterations in conditions, 3 antibodies (Ber-EP4, D2-40, and paired box gene 8 [PAX8]) were not successfully validated. Nearly one-half of the antibodies tested in the current study failed initial validation using IHC conditions that were established in the study laboratory for FFPE material. Although some antibodies subsequently met validation criteria after optimization of conditions, a few continued to demonstrate inadequate immunoreactivity. These findings emphasize the importance of validating IHC protocols for methanol-fixed tissue before clinical use and suggest that optimization for alcohol fixation may be needed to obtain adequate immunoreactivity on CCBs. © 2016 American Cancer Society.
ERIC Educational Resources Information Center
Sandilos, Lia E.
2012-01-01
The purpose of the current study was to evaluate the structural validity and stability of scores on a measure of global classroom quality, the Classroom Assessment Scoring System, Kindergarten-Third Grade (CLASS K-3; Pianta, La Paro, & Hamre, 2008). Using data from a sample of 417 kindergarten classrooms in the rural Southern and Mid-Atlantic…
An error criterion for determining sampling rates in closed-loop control systems
NASA Technical Reports Server (NTRS)
Brecher, S. M.
1972-01-01
The determination of an error criterion which will give a sampling rate for adequate performance of linear, time-invariant closed-loop, discrete-data control systems was studied. The proper modelling of the closed-loop control system for characterization of the error behavior, and the determination of an absolute error definition for performance of the two commonly used holding devices are discussed. The definition of an adequate relative error criterion as a function of the sampling rate and the parameters characterizing the system is established along with the determination of sampling rates. The validity of the expressions for the sampling interval was confirmed by computer simulations. Their application solves the problem of making a first choice in the selection of sampling rates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, R; Baer, E; Jee, K
Purpose: For proton therapy, an accurate model of CT HU to relative stopping power (RSP) conversion is essential. In current practice, validation of these models relies solely on measurements of tissue substitutes with standard compositions. Validation based on real tissue samples would be much more direct and can address variations between patients. This study intends to develop an efficient and accurate system based on the concept of dose extinction to measure WEPL and retrieve RSP in biological tissue in large number of types. Methods: A broad AP proton beam delivering a spread out Bragg peak (SOBP) is used to irradiatemore » the samples with a Matrixx detector positioned immediately below. A water tank was placed on top of the samples, with the water level controllable in sub-millimeter by a remotely controlled dosing pump. While gradually lowering the water level with beam on, the transmission dose was recorded at 1 frame/sec. The WEPL were determined as the difference between the known beam range of the delivered SOBP (80%) and the water level corresponding to 80% of measured dose profiles in time. A Gammex 467 phantom was used to test the system and various types of biological tissue was measured. Results: RSP for all Gammex inserts, expect the one made with lung-450 material (<2% error), were determined within ±0.5% error. Depends on the WEPL of investigated phantom, a measurement takes around 10 min, which can be accelerated by a faster pump. Conclusion: Based on the concept of dose extinction, a system was explored to measure WEPL efficiently and accurately for a large number of samples. This allows the validation of CT HU to stopping power conversions based on large number of samples and real tissues. It also allows the assessment of beam uncertainties due to variations over patients, which issue has never been sufficiently studied before.« less
Merk, Josef; Schlotz, Wolff; Falter, Thomas
2017-01-01
This study presents a new measure of value systems, the Motivational Value Systems Questionnaire (MVSQ), which is based on a theory of value systems by psychologist Clare W. Graves. The purpose of the instrument is to help people identify their personal hierarchies of value systems and thus become more aware of what motivates and demotivates them in work-related contexts. The MVSQ is a forced-choice (FC) measure, making it quicker to complete and more difficult to intentionally distort, but also more difficult to assess its psychometric properties due to ipsativity of FC data compared to rating scales. To overcome limitations of ipsative data, a Thurstonian IRT (TIRT) model was fitted to the questionnaire data, based on a broad sample of N = 1,217 professionals and students. Comparison of normative (IRT) scale scores and ipsative scores suggested that MVSQ IRT scores are largely freed from restrictions due to ipsativity and thus allow interindividual comparison of scale scores. Empirical reliability was estimated using a sample-based simulation approach which showed acceptable and good estimates and, on average, slightly higher test-retest reliabilities. Further, validation studies provided evidence on both construct validity and criterion-related validity. Scale score correlations and associations of scores with both age and gender were largely in line with theoretically- and empirically-based expectations, and results of a multitrait-multimethod analysis supports convergent and discriminant construct validity. Criterion validity was assessed by examining the relation of value system preferences to departmental affiliation which revealed significant relations in line with prior hypothesizing. These findings demonstrate the good psychometric properties of the MVSQ and support its application in the assessment of value systems in work-related contexts. PMID:28979228
Merk, Josef; Schlotz, Wolff; Falter, Thomas
2017-01-01
This study presents a new measure of value systems, the Motivational Value Systems Questionnaire (MVSQ), which is based on a theory of value systems by psychologist Clare W. Graves. The purpose of the instrument is to help people identify their personal hierarchies of value systems and thus become more aware of what motivates and demotivates them in work-related contexts. The MVSQ is a forced-choice (FC) measure, making it quicker to complete and more difficult to intentionally distort, but also more difficult to assess its psychometric properties due to ipsativity of FC data compared to rating scales. To overcome limitations of ipsative data, a Thurstonian IRT (TIRT) model was fitted to the questionnaire data, based on a broad sample of N = 1,217 professionals and students. Comparison of normative (IRT) scale scores and ipsative scores suggested that MVSQ IRT scores are largely freed from restrictions due to ipsativity and thus allow interindividual comparison of scale scores. Empirical reliability was estimated using a sample-based simulation approach which showed acceptable and good estimates and, on average, slightly higher test-retest reliabilities. Further, validation studies provided evidence on both construct validity and criterion-related validity. Scale score correlations and associations of scores with both age and gender were largely in line with theoretically- and empirically-based expectations, and results of a multitrait-multimethod analysis supports convergent and discriminant construct validity. Criterion validity was assessed by examining the relation of value system preferences to departmental affiliation which revealed significant relations in line with prior hypothesizing. These findings demonstrate the good psychometric properties of the MVSQ and support its application in the assessment of value systems in work-related contexts.
Convergent-Discriminant Validity of the Jewish Employment Vocational System (JEVS).
ERIC Educational Resources Information Center
Tryjankowski, Elaine M.
This study investigated the construct validity of five perceptual traits (auditory discrimination, visual discrimination, visual memory, visual-motor coordination, and auditory to visual-motor coordination) with five simulated work samples (union assembly, resistor reading, budgette assembly, lock assembly, and nail and screw sort) from the Jewish…
Aggio, Raphael B. M.; de Lacy Costello, Ben; White, Paul; Khalid, Tanzeela; Ratcliffe, Norman M.; Persad, Raj; Probert, Chris S. J.
2016-01-01
Prostate cancer is one of the most common cancers. Serum prostate-specific antigen (PSA) is used to aid the selection of men undergoing biopsies. Its use remains controversial. We propose a GC-sensor algorithm system for classifying urine samples from patients with urological symptoms. This pilot study includes 155 men presenting to urology clinics, 58 were diagnosed with prostate cancer, 24 with bladder cancer and 73 with haematuria and or poor stream, without cancer. Principal component analysis (PCA) was applied to assess the discrimination achieved, while linear discriminant analysis (LDA) and support vector machine (SVM) were used as statistical models for sample classification. Leave-one-out cross-validation (LOOCV), repeated 10-fold cross-validation (10FoldCV), repeated double cross-validation (DoubleCV) and Monte Carlo permutations were applied to assess performance. Significant separation was found between prostate cancer and control samples, bladder cancer and controls and between bladder and prostate cancer samples. For prostate cancer diagnosis, the GC/SVM system classified samples with 95% sensitivity and 96% specificity after LOOCV. For bladder cancer diagnosis, the SVM reported 96% sensitivity and 100% specificity after LOOCV, while the DoubleCV reported 87% sensitivity and 99% specificity, with SVM showing 78% and 98% sensitivity between prostate and bladder cancer samples. Evaluation of the results of the Monte Carlo permutation of class labels obtained chance-like accuracy values around 50% suggesting the observed results for bladder cancer and prostate cancer detection are not due to over fitting. The results of the pilot study presented here indicate that the GC system is able to successfully identify patterns that allow classification of urine samples from patients with urological cancers. An accurate diagnosis based on urine samples would reduce the number of negative prostate biopsies performed, and the frequency of surveillance cystoscopy for bladder cancer patients. Larger cohort studies are planned to investigate the potential of this system. Future work may lead to non-invasive breath analyses for diagnosing urological conditions. PMID:26865331
NASA Astrophysics Data System (ADS)
Garma, Rey Jan D.
The trade between detector and optics performance is often conveyed through the Q metric, which is defined as the ratio of detector sampling frequency and optical cutoff frequency. Historically sensors have operated at Q ≈ 1, which introduces aliasing but increases the system modulation transfer function (MTF) and signal-to-noise ratio (SNR). Though mathematically suboptimal, such designs have been operationally ideal when considering system parameters such as pointing stability and detector performance. Substantial advances in read noise and quantum efficiency of modern detectors may compensate for the negative aspects associated with balancing detector/optics performance, presenting an opportunity to revisit the potential for implementing Nyquist-sampled (Q ≈ 2) sensors. A digital image chain simulation is developed and validated against a laboratory testbed using objective and subjective assessments. Objective assessments are accomplished by comparison of the modeled MTF and measurements from slant-edge photographs. Subjective assessments are carried out by performing a psychophysical study where subjects are asked to rate simulation and testbed imagery against a DeltaNIIRS scale with the aid of a marker set. Using the validated model, additional test cases are simulated to study the effects of increased detector sampling on image quality with operational considerations. First, a factorial experiment using Q-sampling, pointing stability, integration time, and detector performance is conducted to measure the main effects and interactions of each on the response variable, DeltaNIIRS. To assess the fidelity of current models, variants of the General Image Quality Equation (GIQE) are evaluated against subject-provided ratings and two modified GIQE versions are proposed. Finally, using the validated simulation and modified IQE, trades are conducted to ascertain the feasibility of implementing Q ≈ 2 designs in future systems.
Kashikar-Zuck, Susmita; Carle, Adam; Barnett, Kimberly; Goldschneider, Kenneth R.; Sherry, David D.; Mara, Constance A.; Cunningham, Natoshia; Farrell, Jennifer; Tress, Jenna; DeWitt, Esi Morgan
2015-01-01
The Patient Reported Outcomes Measurement Information System (PROMIS) initiative is a comprehensive strategy by the National Institutes of Health to support the development and validation of precise instruments to assess self-reported health domains across healthy and disease-specific populations. Much progress has been made in instrument development but there remains a gap in the validation of PROMIS measures for pediatric chronic pain. The purpose of this study was to investigate the construct validity and responsiveness to change of seven PROMIS domains for the assessment of children (ages 8-18) with chronic pain – Pain Interference, Fatigue, Anxiety, Depression, Mobility, Upper Extremity Function and Peer Relationships. PROMIS measures were administered at the initial visit and two follow-up visits at an outpatient chronic pain clinic (CPC; N=82) and at an intensive amplified pain day-treatment program (AMP; N= 63). Aim 1 examined construct validity of PROMIS measures by comparing them with corresponding “legacy” measures administered as part of usual care in the CPC sample. Aim 2 examined sensitivity to change in both CPC and AMP samples. Longitudinal growth models showed that PROMIS Pain Interference, Anxiety, Depression, Mobility, Upper Extremity and Peer Relationship measures and legacy instruments generally performed similarly with slightly steeper slopes of improvement in legacy measures. All seven PROMIS domains showed responsiveness to change. Results offered initial support for the validity of PROMIS measures in pediatric chronic pain. Further validation with larger and more diverse pediatric pain samples and additional legacy measures would broaden the scope of use of PROMIS in clinical research. PMID:26447704
Internal validation of the RapidHIT® ID system.
Wiley, Rachel; Sage, Kelly; LaRue, Bobby; Budowle, Bruce
2017-11-01
Traditionally, forensic DNA analysis has required highly skilled forensic geneticists in a dedicated laboratory to generate short tandem repeat (STR) profiles. STR profiles are routinely used either to associate or exclude potential donors of forensic biological evidence. The typing of forensic reference samples has become more demanding, especially with the requirement in some jurisdictions to DNA profile arrestees. The Rapid DNA (RDNA) platform, the RapidHIT ® ID (IntegenX ® , Pleasanton, CA), is a fully automated system capable of processing reference samples in approximately 90min with minimal human intervention. Thus, the RapidHIT ID instrument can be deployed to non-laboratory environments (e.g., booking stations) and run by trained atypical personnel such as law enforcement. In order to implement the RapidHIT ID platform, validation studies are needed to define the performance and limitations of the system. Internal validation studies were undertaken with four early-production RapidHIT ID units. Reliable and concordant STR profiles were obtained from reference buccal swabs. Throughout the study, no contamination was observed. The overall first-pass success rate with an "expert-like system" was 72%, which is comparable to another current RDNA platform commercially available. The system's second-pass success rate (involving manual interpretation on first-pass inconclusive results) increased to 90%. Inhibitors (i.e., coffee, smoking tobacco, and chewing tobacco) did not appear to affect typing by the instrument system; however, substrate (i.e., swab type) did impact typing success. Additionally, one desirable feature not available with other Rapid systems is that in the event of a system failed run, a swab can be recovered and subsequently re-analyzed in a new sample cartridge. Therefore, rarely should additional sampling or swab consumption be necessary. The RapidHIT ID system is a robust and reliable tool capable of generating complete STR profiles within the forensic DNA typing laboratory or with proper training in decentralized environments by non-laboratory personnel. Copyright © 2017 Elsevier B.V. All rights reserved.
Mawn, Michael P; Kurtz, Kristine; Stahl, Deborah; Chalfant, Richard L; Koban, Mary E; Dawson, Barbara J
2013-01-01
A new low global warming refrigerant, 2,3,3,3-tetrafluoro propene, or HFO-1234yf, has been successfully evaluated for automotive air conditioning, and is also being evaluated for stationary refrigeration and air conditioning systems. Due to the advantageous environmental properties of HFO-1234yf versus HFC-134a, coupled with its similar physical properties and system performance, HFO-1234yf is also being evaluated to replace HFC-134a in refrigeration applications where neat HFC-134a is currently used. This study reports on the development and validation of a sampling and analytical method for the determination of HFO-1234yf in air. Different collection media were screened for desorption and simulated sampling efficiency with three-section (350/350/350 mg) Anasorb CSC showing the best results. Therefore, air samples were collected using two 3-section Anasorb CSC sorbent tubes in series at 0.02 L/min for up to 8 hr for sample volumes of up to 9.6 L. The sorbent tubes were extracted in methylene chloride, and analyzed by gas chromatography with flame ionization detection. The method was validated from 0.1× to 20× the target level of 0.5 ppm (2.3 mg/m(3)) for a 9.6 L air volume. Desorption efficiencies for HFO-1234yf were 88 to 109% for all replicates over the validation range with a mean overall recovery of 93%. Simulated sampling efficiencies ranged from 87 to 104% with a mean of 94%. No migration or breakthrough to the back tube was observed under the sampling conditions evaluated. HFO-1234yf samples showed acceptable storage stability on Anasorb CSC sorbent up to a period of 30 days when stored under ambient, refrigerated, or frozen temperature conditions.
A new class of enhanced kinetic sampling methods for building Markov state models
NASA Astrophysics Data System (ADS)
Bhoutekar, Arti; Ghosh, Susmita; Bhattacharya, Swati; Chatterjee, Abhijit
2017-10-01
Markov state models (MSMs) and other related kinetic network models are frequently used to study the long-timescale dynamical behavior of biomolecular and materials systems. MSMs are often constructed bottom-up using brute-force molecular dynamics (MD) simulations when the model contains a large number of states and kinetic pathways that are not known a priori. However, the resulting network generally encompasses only parts of the configurational space, and regardless of any additional MD performed, several states and pathways will still remain missing. This implies that the duration for which the MSM can faithfully capture the true dynamics, which we term as the validity time for the MSM, is always finite and unfortunately much shorter than the MD time invested to construct the model. A general framework that relates the kinetic uncertainty in the model to the validity time, missing states and pathways, network topology, and statistical sampling is presented. Performing additional calculations for frequently-sampled states/pathways may not alter the MSM validity time. A new class of enhanced kinetic sampling techniques is introduced that aims at targeting rare states/pathways that contribute most to the uncertainty so that the validity time is boosted in an effective manner. Examples including straightforward 1D energy landscapes, lattice models, and biomolecular systems are provided to illustrate the application of the method. Developments presented here will be of interest to the kinetic Monte Carlo community as well.
Integrated analyses of proteins and their glycans in a magnetic bead-based multiplex assay format.
Li, Danni; Chiu, Hanching; Chen, Jing; Zhang, Hui; Chan, Daniel W
2013-01-01
Well-annotated clinical samples are valuable resources for biomarker discovery and validation. Multiplex and integrated methods that simultaneously measure multiple analytes and generate integrated information about these analytes from a single measurement are desirable because these methods help conserve precious samples. We developed a magnetic bead-based system for multiplex and integrated glycoprotein quantification by immunoassays and glycan detection by lectin immunosorbent assays (LISAs). Magnetic beads coupled with antibodies were used for capturing proteins of interest. Biotinylated antibodies in combination with streptavidin-labeled phycoerythrin were used for protein quantification. In the LISAs, biotinylated detection antibodies were replaced by biotinylated lectins for glycan detection. Using tissue inhibitor of metallopeptidase 1 (TIMP-1), tissue plasminogen activator, membrane metallo-endopeptidase, and dipeptidyl peptidase-IV (DPP-4) as models, we found that the multiplex integrated system was comparable to single immunoassays in protein quantification and LISAs in glycan detection. The merits of this system were demonstrated when applied to well-annotated prostate cancer tissues for validation of biomarkers in aggressive prostate cancer. Because of the system's multiplex ability, we used only 300 ng of tissue protein for the integrated detection of glycans in these proteins. Fucosylated TIMP-1 and DPP-4 offered improved performance over the proteins in distinguishing aggressive and nonaggressive prostate cancer. The multiplex and integrated system conserves samples and is a useful tool for validation of glycoproteins and their glycoforms as biomarkers. © 2012 American Association for Clinical Chemistry
Certification in Structural Health Monitoring Systems
2011-09-01
validation [3,8]. This may be accomplished by computing the sum of squares of pure error ( SSPE ) and its associated squared correlation [3,8]. To compute...these values, a cross- validation sample must be established. In general, if the SSPE is high, the model does not predict well on independent data...plethora of cross- validation methods, some of which are more useful for certain models than others [3,8]. When possible, a disclosure of the SSPE
NASA Technical Reports Server (NTRS)
Sato, Kevin Y.
2012-01-01
The Bioculture System first flight will be to validate the performance of the hardware and its automated and manual operational capabilities in the space flight environment of the International Space Station. Biology, Engineering, and Operations tests will be conducted in the Bioculture System fully characterize its automated and manual functions to support cell culturing for short and long durations. No hypothesis-driven research will be conducted with biological sample, and the science leads have all provided their concurrence that none of the data they collect will be considered as proprietary and can be free distributed to the science community. The outcome of the validation flight will be to commission the hardware for use by the science community. This presentation will provide non-proprietary details about the Bioculture System and information about the activities for the first flight.
Tsujikawa, Kenji; Kuwayama, Kenji; Miyaguchi, Hajime; Kanamori, Tatsuyuki; Iwata, Yuko T; Yoshida, Takemi; Inoue, Hiroyuki
2008-02-04
We tried to develop a library search system using a portable, attenuated total reflection Fourier transform infrared (ATR-FT-IR) spectrometer for on-site identification of 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyamphetamine (MDA) tablets. The library consisted of the spectra from mixtures of controlled drugs (e.g. MDMA and ketamine), adulterants (e.g. caffeine), and diluents (e.g. lactose). In the seven library search algorithms, the derivative correlation coefficient showed the best discriminant capability. This was enhanced by segmentation of the search area. The optimized search algorithm was validated by the positive (n=154, e.g. the standard mixtures containing the controlled drug, and the MDMA/MDA tablets confiscated) and negative samples (n=56, e.g. medicinal tablets). All validation samples except for four were judged truly. Final criteria for positive identification were decided on the basis of the results of the validation. In conclusion, a portable ATR-FT-IR spectrometer with our library search system would be a useful tool for on-site identification of amphetamine-type stimulant tablets.
von Dincklage, Falk; Lichtner, Gregor; Suchodolski, Klaudiusz; Ragaller, Maximilian; Friesdorf, Wolfgang; Podtschaske, Beatrice
2017-08-01
The implementation of computerized critical care information systems (CCIS) can improve the quality of clinical care and staff satisfaction, but also holds risks of disrupting the workflow with consecutive negative impacts. The usability of CCIS is one of the key factors determining their benefits and weaknesses. However, no tailored instrument exists to measure the usability of such systems. Therefore, the aim of this study was to design and validate a questionnaire that measures the usability of CCIS. Following a mixed-method design approach, we developed a questionnaire comprising two evaluation models to assess the usability of CCIS: (1) the task-specific model rates the usability individually for several tasks which CCIS could support and which we derived by analyzing work processes in the ICU; (2) the characteristic-specific model rates the different aspects of the usability, as defined by the international standard "ergonomics of human-system interaction". We tested validity and reliability of the digital version of the questionnaire in a sample population. In the sample population of 535 participants both usability evaluation models showed a strong correlation with the overall rating of the system (multiple correlation coefficients ≥0.80) as well as a very high internal consistency (Cronbach's alpha ≥0.93). The novel questionnaire is a valid and reliable instrument to measure the usability of CCIS and can be used to study the influence of the usability on their implementation benefits and weaknesses.
Entropy from State Probabilities: Hydration Entropy of Cations
2013-01-01
Entropy is an important energetic quantity determining the progression of chemical processes. We propose a new approach to obtain hydration entropy directly from probability density functions in state space. We demonstrate the validity of our approach for a series of cations in aqueous solution. Extensive validation of simulation results was performed. Our approach does not make prior assumptions about the shape of the potential energy landscape and is capable of calculating accurate hydration entropy values. Sampling times in the low nanosecond range are sufficient for the investigated ionic systems. Although the presented strategy is at the moment limited to systems for which a scalar order parameter can be derived, this is not a principal limitation of the method. The strategy presented is applicable to any chemical system where sufficient sampling of conformational space is accessible, for example, by computer simulations. PMID:23651109
Psychometrics of the MHSIP Adult Consumer Survey.
Jerrell, Jeanette M
2006-10-01
The reliability and validity of the Mental Health Statistics Improvement Program (MHSIP) Adult Consumer Survey were assessed in a statewide convenience sample of 459 persons with severe mental illness served through a public mental health system. Consistent with previous findings and the intent of its developers, three factors were identified that demonstrate good internal consistency, moderate test-retest reliability, and good convergent validity with consumer perceptions of other aspects of their care. The reliability and validity of the MHSIP Adult Consumer Survey documented in this study underscore its scientific and practical utility as an abbreviated tool for assessing access, quality and appropriateness, and outcome in mental health service systems.
Wei, Binnian; Feng, June; Rehmani, Imran J; Miller, Sharyn; McGuffey, James E; Blount, Benjamin C; Wang, Lanqing
2014-09-25
Most sample preparation methods characteristically involve intensive and repetitive labor, which is inefficient when preparing large numbers of samples from population-scale studies. This study presents a robotic system designed to meet the sampling requirements for large population-scale studies. Using this robotic system, we developed and validated a method to simultaneously measure urinary anatabine, anabasine, nicotine and seven major nicotine metabolites: 4-Hydroxy-4-(3-pyridyl)butanoic acid, cotinine-N-oxide, nicotine-N-oxide, trans-3'-hydroxycotinine, norcotinine, cotinine and nornicotine. We analyzed robotically prepared samples using high-performance liquid chromatography (HPLC) coupled with triple quadrupole mass spectrometry in positive electrospray ionization mode using scheduled multiple reaction monitoring (sMRM) with a total runtime of 8.5 min. The optimized procedure was able to deliver linear analyte responses over a broad range of concentrations. Responses of urine-based calibrators delivered coefficients of determination (R(2)) of >0.995. Sample preparation recovery was generally higher than 80%. The robotic system was able to prepare four 96-well plate (384 urine samples) per day, and the overall method afforded an accuracy range of 92-115%, and an imprecision of <15.0% on average. The validation results demonstrate that the method is accurate, precise, sensitive, robust, and most significantly labor-saving for sample preparation, making it efficient and practical for routine measurements in large population-scale studies such as the National Health and Nutrition Examination Survey (NHANES) and the Population Assessment of Tobacco and Health (PATH) study. Published by Elsevier B.V.
Validation of the Seating and Mobility Script Concordance Test
ERIC Educational Resources Information Center
Cohen, Laura J.; Fitzgerald, Shirley G.; Lane, Suzanne; Boninger, Michael L.; Minkel, Jean; McCue, Michael
2009-01-01
The purpose of this study was to develop the scoring system for the Seating and Mobility Script Concordance Test (SMSCT), obtain and appraise internal and external structure evidence, and assess the validity of the SMSCT. The SMSCT purpose is to provide a method for testing knowledge of seating and mobility prescription. A sample of 106 therapists…
A scoring system for ascertainment of incident stroke; the Risk Index Score (RISc).
Kass-Hout, T A; Moyé, L A; Smith, M A; Morgenstern, L B
2006-01-01
The main objective of this study was to develop and validate a computer-based statistical algorithm that could be translated into a simple scoring system in order to ascertain incident stroke cases using hospital admission medical records data. The Risk Index Score (RISc) algorithm was developed using data collected prospectively by the Brain Attack Surveillance in Corpus Christi (BASIC) project, 2000. The validity of RISc was evaluated by estimating the concordance of scoring system stroke ascertainment to stroke ascertainment by physician and/or abstractor review of hospital admission records. RISc was developed on 1718 randomly selected patients (training set) and then statistically validated on an independent sample of 858 patients (validation set). A multivariable logistic model was used to develop RISc and subsequently evaluated by goodness-of-fit and receiver operating characteristic (ROC) analyses. The higher the value of RISc, the higher the patient's risk of potential stroke. The study showed RISc was well calibrated and discriminated those who had potential stroke from those that did not on initial screening. In this study we developed and validated a rapid, easy, efficient, and accurate method to ascertain incident stroke cases from routine hospital admission records for epidemiologic investigations. Validation of this scoring system was achieved statistically; however, clinical validation in a community hospital setting is warranted.
Chaitanya, Lakshmi; Breslin, Krystal; Zuñiga, Sofia; Wirken, Laura; Pośpiech, Ewelina; Kukla-Bartoszek, Magdalena; Sijen, Titia; Knijff, Peter de; Liu, Fan; Branicki, Wojciech; Kayser, Manfred; Walsh, Susan
2018-07-01
Forensic DNA Phenotyping (FDP), i.e. the prediction of human externally visible traits from DNA, has become a fast growing subfield within forensic genetics due to the intelligence information it can provide from DNA traces. FDP outcomes can help focus police investigations in search of unknown perpetrators, who are generally unidentifiable with standard DNA profiling. Therefore, we previously developed and forensically validated the IrisPlex DNA test system for eye colour prediction and the HIrisPlex system for combined eye and hair colour prediction from DNA traces. Here we introduce and forensically validate the HIrisPlex-S DNA test system (S for skin) for the simultaneous prediction of eye, hair, and skin colour from trace DNA. This FDP system consists of two SNaPshot-based multiplex assays targeting a total of 41 SNPs via a novel multiplex assay for 17 skin colour predictive SNPs and the previous HIrisPlex assay for 24 eye and hair colour predictive SNPs, 19 of which also contribute to skin colour prediction. The HIrisPlex-S system further comprises three statistical prediction models, the previously developed IrisPlex model for eye colour prediction based on 6 SNPs, the previous HIrisPlex model for hair colour prediction based on 22 SNPs, and the recently introduced HIrisPlex-S model for skin colour prediction based on 36 SNPs. In the forensic developmental validation testing, the novel 17-plex assay performed in full agreement with the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines, as previously shown for the 24-plex assay. Sensitivity testing of the 17-plex assay revealed complete SNP profiles from as little as 63 pg of input DNA, equalling the previously demonstrated sensitivity threshold of the 24-plex HIrisPlex assay. Testing of simulated forensic casework samples such as blood, semen, saliva stains, of inhibited DNA samples, of low quantity touch (trace) DNA samples, and of artificially degraded DNA samples as well as concordance testing, demonstrated the robustness, efficiency, and forensic suitability of the new 17-plex assay, as previously shown for the 24-plex assay. Finally, we provide an update to the publically available HIrisPlex website https://hirisplex.erasmusmc.nl/, now allowing the estimation of individual probabilities for 3 eye, 4 hair, and 5 skin colour categories from HIrisPlex-S input genotypes. The HIrisPlex-S DNA test represents the first forensically validated tool for skin colour prediction, and reflects the first forensically validated tool for simultaneous eye, hair and skin colour prediction from DNA. Copyright © 2018 Elsevier B.V. All rights reserved.
Fluorescence In Situ Hybridization Probe Validation for Clinical Use.
Gu, Jun; Smith, Janice L; Dowling, Patricia K
2017-01-01
In this chapter, we provide a systematic overview of the published guidelines and validation procedures for fluorescence in situ hybridization (FISH) probes for clinical diagnostic use. FISH probes-which are classified as molecular probes or analyte-specific reagents (ASRs)-have been extensively used in vitro for both clinical diagnosis and research. Most commercially available FISH probes in the United States are strictly regulated by the U.S. Food and Drug Administration (FDA), the Centers for Disease Control and Prevention (CDC), the Centers for Medicare & Medicaid Services (CMS) the Clinical Laboratory Improvement Amendments (CLIA), and the College of American Pathologists (CAP). Although home-brewed FISH probes-defined as probes made in-house or acquired from a source that does not supply them to other laboratories-are not regulated by these agencies, they too must undergo the same individual validation process prior to clinical use as their commercial counterparts. Validation of a FISH probe involves initial validation and ongoing verification of the test system. Initial validation includes assessment of a probe's technical specifications, establishment of its standard operational procedure (SOP), determination of its clinical sensitivity and specificity, development of its cutoff, baseline, and normal reference ranges, gathering of analytics, confirmation of its applicability to a specific research or clinical setting, testing of samples with or without the abnormalities that the probe is meant to detect, staff training, and report building. Ongoing verification of the test system involves testing additional normal and abnormal samples using the same method employed during the initial validation of the probe.
Maier, Jürgen; Hampe, J Felix; Jahn, Nico
2016-01-01
Real-time response (RTR) measurement is an important technique for analyzing human processing of electronic media stimuli. Although it has been demonstrated that RTR data are reliable and internally valid, some argue that they lack external validity. The reason for this is that RTR measurement is restricted to a laboratory environment due to its technical requirements. This paper introduces a smartphone app that 1) captures real-time responses using the dial technique and 2) provides a solution for one of the most important problems in RTR measurement, the (automatic) synchronization of RTR data. In addition, it explores the reliability and validity of mobile RTR measurement by comparing the real-time reactions of two samples of young and well-educated voters to the 2013 German televised debate. Whereas the first sample participated in a classical laboratory study, the second sample was equipped with our mobile RTR system and watched the debate at home. Results indicate that the mobile RTR system yields similar results to the lab-based RTR measurement, providing evidence that laboratory studies using RTR are externally valid. In particular, the argument that the artificial reception situation creates artificial results has to be questioned. In addition, we conclude that RTR measurement outside the lab is possible. Hence, mobile RTR opens the door for large-scale studies to better understand the processing and impact of electronic media content.
Maier, Jürgen; Hampe, J. Felix; Jahn, Nico
2016-01-01
Real-time response (RTR) measurement is an important technique for analyzing human processing of electronic media stimuli. Although it has been demonstrated that RTR data are reliable and internally valid, some argue that they lack external validity. The reason for this is that RTR measurement is restricted to a laboratory environment due to its technical requirements. This paper introduces a smartphone app that 1) captures real-time responses using the dial technique and 2) provides a solution for one of the most important problems in RTR measurement, the (automatic) synchronization of RTR data. In addition, it explores the reliability and validity of mobile RTR measurement by comparing the real-time reactions of two samples of young and well-educated voters to the 2013 German televised debate. Whereas the first sample participated in a classical laboratory study, the second sample was equipped with our mobile RTR system and watched the debate at home. Results indicate that the mobile RTR system yields similar results to the lab-based RTR measurement, providing evidence that laboratory studies using RTR are externally valid. In particular, the argument that the artificial reception situation creates artificial results has to be questioned. In addition, we conclude that RTR measurement outside the lab is possible. Hence, mobile RTR opens the door for large-scale studies to better understand the processing and impact of electronic media content. PMID:27274577
Cronly, Mark; Behan, P; Foley, B; Malone, E; Earley, S; Gallagher, M; Shearan, P; Regan, L
2010-12-01
A confirmatory method has been developed to allow for the analysis of fourteen prohibited medicinal additives in pig and poultry compound feed. These compounds are prohibited for use as feed additives although some are still authorised for use in medicated feed. Feed samples are extracted by acetonitrile with addition of sodium sulfate. The extracts undergo a hexane wash to aid with sample purification. The extracts are then evaporated to dryness and reconstituted in initial mobile phase. The samples undergo an ultracentrifugation step prior to injection onto the LC-MS/MS system and are analysed in a run time of 26 min. The LC-MS/MS system is run in MRM mode with both positive and negative electrospray ionisation. The method was validated over three days and is capable of quantitatively analysing for metronidazole, dimetridazole, ronidazole, ipronidazole, chloramphenicol, sulfamethazine, dinitolimide, ethopabate, carbadox and clopidol. The method is also capable of qualitatively analysing for sulfadiazine, tylosin, virginiamycin and avilamycin. A level of 100 microg kg(-1) was used for validation purposes and the method is capable of analysing to this level for all the compounds. Validation criteria of trueness, precision, repeatability and reproducibility along with measurement uncertainty are calculated for all analytes. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Kruizenga, H M; de Vet, H C W; Van Marissing, C M E; Stassen, E E P M; Strijk, J E; Van Bokhorst-de Van der Schueren, M A E; Horman, J C H; Schols, J M G A; Van Binsbergen, J J; Eliens, A; Knol, D L; Visser, M
2010-02-01
Development and validation of a quick and easy screening tool for the early detection of undernourished residents in nursing homes and residential homes. Multi-center, cross sectional observational study. Nursing homes and residential homes. The screening tool was developed in a total of 308 residents (development sample; sample A) and cross validated in a new sample of 720 residents (validation sample) consisting of 476 nursing home residents (Sample B1) and 244 residential home residents (sample B2). Patients were defined severely undernourished when they met at least one of the following criteria: BMI
Hediger, Hannele; Müller-Staub, Maria; Petry, Heidi
2016-01-01
Electronic nursing documentation systems, with standardized nursing terminology, are IT-based systems for recording the nursing processes. These systems have the potential to improve the documentation of the nursing process and to support nurses in care delivery. This article describes the development and initial validation of an instrument (known by its German acronym UEPD) to measure the subjectively-perceived benefits of an electronic nursing documentation system in care delivery. The validity of the UEPD was examined by means of an evaluation study carried out in an acute care hospital (n = 94 nurses) in German-speaking Switzerland. Construct validity was analyzed by principal components analysis. Initial references of validity of the UEPD could be verified. The analysis showed a stable four factor model (FS = 0.89) scoring in 25 items. All factors loaded ≥ 0.50 and the scales demonstrated high internal consistency (Cronbach's α = 0.73 – 0.90). Principal component analysis revealed four dimensions of support: establishing nursing diagnosis and goals; recording a case history/an assessment and documenting the nursing process; implementation and evaluation as well as information exchange. Further testing with larger control samples and with different electronic documentation systems are needed. Another potential direction would be to employ the UEPD in a comparison of various electronic documentation systems.
A Performance Appraisal System for School Principals.
ERIC Educational Resources Information Center
Knoop, Robert; Common, Ronald W.
The Performance Review, Analysis, and Improvement System for Educators (PRAISE) is a formative evaluation instrument designed to improve the performance of school principals. The system appears to be reliable and valid and is flexible enough to accommodate the needs of a variety of schools. Sample items and categories of the instrument include…
[Wound microbial sampling methods in surgical practice, imprint techniques].
Chovanec, Z; Veverková, L; Votava, M; Svoboda, J; Peštál, A; Doležel, J; Jedlička, V; Veselý, M; Wechsler, J; Čapov, I
2012-12-01
The wound is a damage of tissue. The process of healing is influenced by many systemic and local factors. The most crucial and the most discussed local factor of wound healing is infection. Surgical site infection in the wound is caused by micro-organisms. This information is known for many years, however the conditions leading to an infection occurrence have not been sufficiently described yet. Correct sampling technique, correct storage, transportation, evaluation, and valid interpretation of these data are very important in clinical practice. There are many methods for microbiological sampling, but the best one has not been yet identified and validated. We aim to discuss the problem with the focus on the imprint technique.
Serial data correlator/code translator
NASA Technical Reports Server (NTRS)
Morgan, L. E. (Inventor)
1982-01-01
A system for analyzing asynchronous signals containing bits of information for ensuring the validity of said signals, by sampling each bit of information a plurality of times, and feeding the sampled pieces of bits of information into a sequence controlled is described. The sequence controller has a plurality of maps or programs through which the sampled pieces of bits are stepped so as to identify the particular bit of information and determine the validity and phase of the bit. The step in which the sequence controller is clocked is controlled by a storage register. A data decoder decodes the information fed out of the storage register and feeds such information to shift registers for storage.
77 FR 27135 - HACCP Systems Validation
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-09
.... Comments may be submitted by either of the following methods: Federal eRulemaking Portal: This Web site... those CCPs and the method of monitoring of them and provides certificates of analysis that specify the sampling method that the supplier uses and the results of that sampling. The receiving establishment should...
Pinsof, William M; Zinbarg, Richard E; Shimokawa, Kenichi; Latta, Tara A; Goldsmith, Jacob Z; Knobloch-Fedders, Lynne M; Chambers, Anthony L; Lebow, Jay L
2015-09-01
Progress or feedback research tracks and feeds back client progress data throughout the course of psychotherapy. In the effort to empirically ground psychotherapeutic practice, feedback research is both a complement and alternative to empirically supported manualized treatments. Evidence suggests that tracking and feeding back progress data with individual or nonsystemic feedback systems improves outcomes in individual and couple therapy. The research reported in this article pertains to the STIC(®) (Systemic Therapy Inventory of Change)-the first client-report feedback system designed to empirically assess and track change within client systems from multisystemic and multidimensional perspectives in individual, couple, and family therapy. Clients complete the STIC Initial before the first session and the shorter STIC Intersession before every subsequent session. This study tested and its results supported the hypothesized factor structure of the six scales that comprise both STIC forms in a clinical outpatient sample and in a normal, random representative sample of the U.S. This study also tested the STIC's concurrent validity and found that its 6 scales and 40 of its 41 subscales differentiated the clinical and normal samples. Lastly, the study derived clinical cut-offs for each scale and subscale to determine whether and how much a client's score falls in the normal or clinical range. Beyond supporting the factorial and concurrent validity of both STIC forms, this research supported the reliabilities of the six scales (Omegahierarchical ) as well as the reliabilities of most subscales (alpha and rate-rerate). This article delineates clinical implications and directions for future research. © 2015 Family Process Institute.
Rehem, Tania Cristina Morais Santa Barbara; de Oliveira, Maria Regina Fernandes; Ciosak, Suely Itsuko; Egry, Emiko Yoshikawa
2013-01-01
To estimate the sensitivity, specificity and positive and negative predictive values of the Unified Health System's Hospital Information System for the appropriate recording of hospitalizations for ambulatory care-sensitive conditions. The hospital information system records for conditions which are sensitive to ambulatory care, and for those which are not, were considered for analysis, taking the medical records as the gold standard. Through simple random sampling, a sample of 816 medical records was defined and selected by means of a list of random numbers using the Statistical Package for Social Sciences. The sensitivity was 81.89%, specificity was 95.19%, the positive predictive value was 77.61% and the negative predictive value was 96.27%. In the study setting, the Hospital Information System (SIH) was more specific than sensitive, with nearly 20% of care sensitive conditions not detected. There are no validation studies in Brazil of the Hospital Information System records for the hospitalizations which are sensitive to primary health care. These results are relevant when one considers that this system is one of the bases for assessment of the effectiveness of primary health care.
DuPont Qualicon BAX System polymerase chain reaction assay. Performance Tested Method 100201.
Tice, George; Andaloro, Bridget; Fallon, Dawn; Wallace, F Morgan
2009-01-01
A recent outbreak of Salmonella in peanut butter has highlighted the need for validation of rapid detection methods. A multilaboratory study for detecting Salmonella in peanut butter was conducted as part of the AOAC Research Institute Emergency Response Validation program for methods that detect outbreak threats to food safety. Three sites tested spiked samples from the same master mix according to the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA-BAM) method and the BAX System method. Salmonella Typhimurium (ATCC 14028) was grown in brain heart infusion for 24 h at 37 degrees C, then diluted to appropriate levels for sample inoculation. Master samples of peanut butter were spiked at high and low target levels, mixed, and allowed to equilibrate at room temperature for 2 weeks. Spike levels were low [1.08 most probable number (MPN)/25 g]; high (11.5 MPN/25 g) and unspiked to serve as negative controls. Each master sample was divided into 25 g portions and coded to blind the samples. Twenty portions of each spiked master sample and five portions of the unspiked sample were tested at each site. At each testing site, samples were blended in 25 g portions with 225 mL prewarmed lactose broth until thoroughly homogenized, then allowed to remain at room temperature for 55-65 min. Samples were adjusted to a pH of 6.8 +/- 0.2, if necessary, and incubated for 22-26 h at 35 degrees C. Across the three reporting laboratories, the BAX System detected Salmonella in 10/60 low-spike samples and 58/60 high-spike samples. The reference FDA-BAM method yielded positive results for 11/60 low-spike and 58/60 high-spike samples. Neither method demonstrated positive results for any of the 15 unspiked samples.
Risk score to predict the outcome of patients with cerebral vein and dural sinus thrombosis.
Ferro, José M; Bacelar-Nicolau, Helena; Rodrigues, Teresa; Bacelar-Nicolau, Leonor; Canhão, Patrícia; Crassard, Isabelle; Bousser, Marie-Germaine; Dutra, Aurélio Pimenta; Massaro, Ayrton; Mackowiack-Cordiolani, Marie-Anne; Leys, Didier; Fontes, João; Stam, Jan; Barinagarrementeria, Fernando
2009-01-01
Around 15% of patients die or become dependent after cerebral vein and dural sinus thrombosis (CVT). We used the International Study on Cerebral Vein and Dural Sinus Thrombosis (ISCVT) sample (624 patients, with a median follow-up time of 478 days) to develop a Cox proportional hazards regression model to predict outcome, dichotomised by a modified Rankin Scale score >2. From the model hazard ratios, a risk score was derived and a cut-off point selected. The model and the score were tested in 2 validation samples: (1) the prospective Cerebral Venous Thrombosis Portuguese Collaborative Study Group (VENOPORT) sample with 91 patients; (2) a sample of 169 consecutive CVT patients admitted to 5 ISCVT centres after the end of the ISCVT recruitment period. Sensitivity, specificity, c statistics and overall efficiency to predict outcome at 6 months were calculated. The model (hazard ratios: malignancy 4.53; coma 4.19; thrombosis of the deep venous system 3.03; mental status disturbance 2.18; male gender 1.60; intracranial haemorrhage 1.42) had overall efficiencies of 85.1, 84.4 and 90.0%, in the derivation sample and validation samples 1 and 2, respectively. Using the risk score (range from 0 to 9) with a cut-off of >or=3 points, overall efficiency was 85.4, 84.4 and 90.1% in the derivation sample and validation samples 1 and 2, respectively. Sensitivity and specificity in the combined samples were 96.1 and 13.6%, respectively. The CVT risk score has a good estimated overall rate of correct classifications in both validation samples, but its specificity is low. It can be used to avoid unnecessary or dangerous interventions in low-risk patients, and may help to identify high-risk CVT patients. (c) 2009 S. Karger AG, Basel.
Castañeda, María; Odriozola, Adrián; Gómez, Javier; Zarrabeitia, María T
2013-07-01
We report the development of an effective system for analyzing X chromosome-linked mini short tandem repeat loci with reduced-size amplicons (less than 220 bp), useful for analyzing highly degraded DNA samples. To generate smaller amplicons, we redesigned primers for eight X-linked microsatellites (DXS7132, DXS10079, DXS10074, DXS10075, DXS6801, DXS6809, DXS6789, and DXS6799) and established efficient conditions for a multiplex PCR system (miniX). The validation tests confirmed that it has good sensitivity, requiring as little as 20 pg of DNA, and performs well with DNA from paraffin-embedded tissues, thus showing potential for improved analysis and identification of highly degraded and/or very limited DNA samples. Consequently, this system may help to solve complex forensic cases, particularly when autosomal markers convey insufficient information.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hertzler, C.L.; Poloski, J.P.; Bates, R.A.
1988-01-01
The Compliance Program Data Management System (DMS) developed at the Idaho National Engineering Laboratory (INEL) validates and maintains the integrity of data collected to support the Consent Order and Compliance Agreement (COCA) between the INEL and the Environmental Protection Agency (EPA). The system uses dBase III Plus programs and dBase III Plus in an interactive mode to enter, store, validate, manage, and retrieve analytical information provided on EPA Contract Laboratory Program (CLP) forms and CLP forms modified to accommodate 40 CFR 264 Appendix IX constituent analyses. Data analysis and presentation is performed utilizing SAS, a statistical analysis software program. Archivingmore » of data and results is performed at appropriate stages of data management. The DMS is useful for sampling and analysis programs where adherence to EPA CLP protocol, along with maintenance and retrieval of waste site investigation sampling results is desired or requested. 3 refs.« less
Validity of the Family Asthma Management System Scale with an urban African-American sample.
Celano, Marianne; Klinnert, Mary D; Holsey, Chanda Nicole; McQuaid, Elizabeth L
2011-06-01
To examine the reliability and validity of the Family Asthma Management System Scale for low-income African-American children with poor asthma control and caregivers under stress. The FAMSS assesses eight aspects of asthma management from a family systems perspective. Forty-three children, ages 8-13, and caregivers were interviewed with the FAMSS; caregivers completed measures of primary care quality, family functioning, parenting stress, and psychological distress. Children rated their relatedness with the caregiver, and demonstrated inhaler technique. Medical records were reviewed for dates of outpatient visits for asthma. The FAMSS demonstrated good internal consistency. Higher scores were associated with adequate inhaler technique, recent outpatient care, less parenting stress and better family functioning. Higher scores on the Collaborative Relationship with Provider subscale were associated with greater perceived primary care quality. The FAMSS demonstrated relevant associations with asthma management criteria and family functioning for a low-income, African-American sample.
Eichhold, Thomas H; McCauley-Myers, David L; Khambe, Deepa A; Thompson, Gary A; Hoke, Steven H
2007-01-17
A method for the simultaneous determination of dextromethorphan (DEX), dextrorphan (DET), and guaifenesin (GG) in human plasma was developed, validated, and applied to determine plasma concentrations of these compounds in samples from six clinical pharmacokinetic (PK) studies. Semi-automated liquid handling systems were used to perform the majority of the sample manipulation including liquid/liquid extraction (LLE) of the analytes from human plasma. Stable-isotope-labeled analogues were utilized as internal standards (ISTDs) for each analyte to facilitate accurate and precise quantification. Extracts were analyzed using gradient liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Use of semi-automated LLE with LC-MS/MS proved to be a very rugged and reliable approach for analysis of more than 6200 clinical study samples. The lower limit of quantification was validated at 0.010, 0.010, and 1.0 ng/mL of plasma for DEX, DET, and GG, respectively. Accuracy and precision of quality control (QC) samples for all three analytes met FDA Guidance criteria of +/-15% for average QC accuracy with coefficients of variation less than 15%. Data from the thorough evaluation of the method during development, validation, and application are presented to characterize selectivity, linearity, over-range sample analysis, accuracy, precision, autosampler carry-over, ruggedness, extraction efficiency, ionization suppression, and stability. Pharmacokinetic data are also provided to illustrate improvements in systemic drug and metabolite concentration-time profiles that were achieved by formulation optimization.
Yen, Po-Yin; Sousa, Karen H; Bakken, Suzanne
2014-01-01
Background In a previous study, we developed the Health Information Technology Usability Evaluation Scale (Health-ITUES), which is designed to support customization at the item level. Such customization matches the specific tasks/expectations of a health IT system while retaining comparability at the construct level, and provides evidence of its factorial validity and internal consistency reliability through exploratory factor analysis. Objective In this study, we advanced the development of Health-ITUES to examine its construct validity and predictive validity. Methods The health IT system studied was a web-based communication system that supported nurse staffing and scheduling. Using Health-ITUES, we conducted a cross-sectional study to evaluate users’ perception toward the web-based communication system after system implementation. We examined Health-ITUES's construct validity through first and second order confirmatory factor analysis (CFA), and its predictive validity via structural equation modeling (SEM). Results The sample comprised 541 staff nurses in two healthcare organizations. The CFA (n=165) showed that a general usability factor accounted for 78.1%, 93.4%, 51.0%, and 39.9% of the explained variance in ‘Quality of Work Life’, ‘Perceived Usefulness’, ‘Perceived Ease of Use’, and ‘User Control’, respectively. The SEM (n=541) supported the predictive validity of Health-ITUES, explaining 64% of the variance in intention for system use. Conclusions The results of CFA and SEM provide additional evidence for the construct and predictive validity of Health-ITUES. The customizability of Health-ITUES has the potential to support comparisons at the construct level, while allowing variation at the item level. We also illustrate application of Health-ITUES across stages of system development. PMID:24567081
Enjeti, Anoop; Granter, Neil; Ashraf, Asma; Fletcher, Linda; Branford, Susan; Rowlings, Philip; Dooley, Susan
2015-10-01
An automated cartridge-based detection system (GeneXpert; Cepheid) is being widely adopted in low throughput laboratories for monitoring BCR-ABL1 transcript in chronic myelogenous leukaemia. This Australian study evaluated the longitudinal performance specific characteristics of the automated system.The automated cartridge-based system was compared prospectively with the manual qRT-PCR-based reference method at SA Pathology, Adelaide, over a period of 2.5 years. A conversion factor determination was followed by four re-validations. Peripheral blood samples (n = 129) with international scale (IS) values within detectable range were selected for assessment. The mean bias, proportion of results within specified fold difference (2-, 3- and 5-fold), the concordance rate of major molecular remission (MMR) and concordance across a range of IS values on paired samples were evaluated.The initial conversion factor for the automated system was determined as 0.43. Except for the second re-validation, where a negative bias of 1.9-fold was detected, all other biases fell within desirable limits. A cartridge-specific conversion factor and efficiency value was introduced and the conversion factor was confirmed to be stable in subsequent re-validation cycles. Concordance with the reference method/laboratory at >0.1-≤10 IS was 78.2% and at ≤0.001 was 80%, compared to 86.8% in the >0.01-≤0.1 IS range. The overall and MMR concordance were 85.7% and 94% respectively, for samples that fell within ± 5-fold of the reference laboratory value over the entire period of study.Conversion factor and performance specific characteristics for the automated system were longitudinally stable in the clinically relevant range, following introduction by the manufacturer of lot specific efficiency values.
Citera, Maryalice; Freeman, Phyllis R; Horowitz, Richard I
2017-01-01
Lyme disease is spreading worldwide, with multiple Borrelia species causing a broad range of clinical symptoms that mimic other illnesses. A validated Lyme disease screening questionnaire would be clinically useful for both providers and patients. Three studies evaluated such a screening tool, namely the Horowitz Multiple Systemic Infectious Disease Syndrome (MSIDS) Questionnaire. The purpose was to see if the questionnaire could accurately distinguish between Lyme patients and healthy individuals. Study 1 examined the construct validity of the scale examining its factor structure and reliability of the questionnaire among 537 individuals being treated for Lyme disease. Study 2 involved an online sample of 999 participants, who self-identified as either healthy (N=217) or suffering from Lyme now (N=782) who completed the Horowitz MSIDS Questionnaire (HMQ) along with an outdoor activity survey. We examined convergent validity among components of the scale and evaluated discriminant validity with the Big Five personality characteristics. The third study compared a sample of 236 patients with confirmed Lyme disease with an online sample of 568 healthy individuals. Factor analysis results identified six underlying latent dimensions; four of these overlapped with critical symptoms identified by Horowitz - neuropathy, cognitive dysfunction, musculoskeletal pain, and fatigue. The HMQ showed acceptable levels of internal reliability using Cronbach's coefficient alpha and exhibited evidence of convergent and divergent validity. Components of the HMQ correlated more highly with each other than with unrelated traits. The results consistently demonstrated that the HMQ accurately differentiated those with Lyme disease from healthy individuals. Three migratory pain survey items (persistent muscular pain, arthritic pain, and nerve pain/paresthesias) robustly identified individuals with verified Lyme disease. The results support the use of the HMQ as a valid, efficient, and low-cost screening tool for medical practitioners to decide if additional testing is warranted to distinguish between Lyme disease and other illnesses.
Citera, Maryalice; Freeman, Phyllis R; Horowitz, Richard I
2017-01-01
Purpose Lyme disease is spreading worldwide, with multiple Borrelia species causing a broad range of clinical symptoms that mimic other illnesses. A validated Lyme disease screening questionnaire would be clinically useful for both providers and patients. Three studies evaluated such a screening tool, namely the Horowitz Multiple Systemic Infectious Disease Syndrome (MSIDS) Questionnaire. The purpose was to see if the questionnaire could accurately distinguish between Lyme patients and healthy individuals. Methods Study 1 examined the construct validity of the scale examining its factor structure and reliability of the questionnaire among 537 individuals being treated for Lyme disease. Study 2 involved an online sample of 999 participants, who self-identified as either healthy (N=217) or suffering from Lyme now (N=782) who completed the Horowitz MSIDS Questionnaire (HMQ) along with an outdoor activity survey. We examined convergent validity among components of the scale and evaluated discriminant validity with the Big Five personality characteristics. The third study compared a sample of 236 patients with confirmed Lyme disease with an online sample of 568 healthy individuals. Results Factor analysis results identified six underlying latent dimensions; four of these overlapped with critical symptoms identified by Horowitz – neuropathy, cognitive dysfunction, musculoskeletal pain, and fatigue. The HMQ showed acceptable levels of internal reliability using Cronbach’s coefficient alpha and exhibited evidence of convergent and divergent validity. Components of the HMQ correlated more highly with each other than with unrelated traits. Discussion The results consistently demonstrated that the HMQ accurately differentiated those with Lyme disease from healthy individuals. Three migratory pain survey items (persistent muscular pain, arthritic pain, and nerve pain/paresthesias) robustly identified individuals with verified Lyme disease. The results support the use of the HMQ as a valid, efficient, and low-cost screening tool for medical practitioners to decide if additional testing is warranted to distinguish between Lyme disease and other illnesses. PMID:28919803
Psychometric Testing of a Religious Belief Scale.
Chiang, Yi-Chien; Lee, Hsiang-Chun; Chu, Tsung-Lan; Han, Chin-Yen; Hsiao, Ya-Chu
2017-12-01
Nurses account for a significant percentage of staff in the healthcare system. The religious beliefs of nurses may affect their competence to provide spiritual care to patients. No reliable and valid instruments are currently available to measure the religious beliefs of nurses in Taiwan. The aims of this study were to develop a religious belief scale (RBS) for Taiwanese nurses and to evaluate the psychometric properties of this scale. A cross-sectional study design was used, and 24 RBS items were generated from in-depth interviews, a literature review, and expert recommendations. The RBS self-administered questionnaire was provided to 619 clinical nurses, who were recruited from two medical centers and one local hospital in Taiwan during 2011-2012. A calibration sample was used to explore the factor structure, whereas a validation sample was used to validate the factor structure that was constructed by the calibration sample. Known-group validity and criterion-related validity were also assessed. An exploratory factor analysis resulted in an 18-item RBS with four factors, including "religious effects," "divine," "religious query," and "religious stress." A confirmatory factor analysis recommended the deletion of one item, resulting in a final RBS of 17 items. The convergent validity and discriminate validity of the RBS were acceptable. The RBS correlated positively with spiritual health and supported concurrent validity. The known-group validity was supported by showing that the mean RBS between nurses with or without religious affiliation was significant. The 17-item RBS developed in this study is a reliable, valid, and useful scale for measuring the religious beliefs of nurses in Taiwan. This scale may help measure the religious beliefs of nurses and elicit the relationship between these beliefs and spirituality.
Development and validation of an HPLC–MS/MS method to determine clopidogrel in human plasma
Liu, Gangyi; Dong, Chunxia; Shen, Weiwei; Lu, Xiaopei; Zhang, Mengqi; Gui, Yuzhou; Zhou, Qinyi; Yu, Chen
2015-01-01
A quantitative method for clopidogrel using online-SPE tandem LC–MS/MS was developed and fully validated according to the well-established FDA guidelines. The method achieves adequate sensitivity for pharmacokinetic studies, with lower limit of quantifications (LLOQs) as low as 10 pg/mL. Chromatographic separations were performed on reversed phase columns Kromasil Eternity-2.5-C18-UHPLC for both methods. Positive electrospray ionization in multiple reaction monitoring (MRM) mode was employed for signal detection and a deuterated analogue (clopidogrel-d4) was used as internal standard (IS). Adjustments in sample preparation, including introduction of an online-SPE system proved to be the most effective method to solve the analyte back-conversion in clinical samples. Pooled clinical samples (two levels) were prepared and successfully used as real-sample quality control (QC) in the validation of back-conversion testing under different conditions. The result showed that the real samples were stable in room temperature for 24 h. Linearity, precision, extraction recovery, matrix effect on spiked QC samples and stability tests on both spiked QCs and real sample QCs stored in different conditions met the acceptance criteria. This online-SPE method was successfully applied to a bioequivalence study of 75 mg single dose clopidogrel tablets in 48 healthy male subjects. PMID:26904399
Walsh, Susan; Lindenbergh, Alexander; Zuniga, Sofia B; Sijen, Titia; de Knijff, Peter; Kayser, Manfred; Ballantyne, Kaye N
2011-11-01
The IrisPlex system consists of a highly sensitive multiplex genotyping assay together with a statistical prediction model, providing users with the ability to predict blue and brown human eye colour from DNA samples with over 90% precision. This 'DNA intelligence' system is expected to aid police investigations by providing phenotypic information on unknown individuals when conventional DNA profiling is not informative. Falling within the new area of forensic DNA phenotyping, this paper describes the developmental validation of the IrisPlex assay following the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines for the application of DNA-based eye colour prediction to forensic casework. The IrisPlex assay produces complete SNP genotypes with only 31pg of DNA, approximately six human diploid cell equivalents, and is therefore more sensitive than commercial STR kits currently used in forensics. Species testing revealed human and primate specificity for a complete SNP profile. The assay is capable of producing accurate results from simulated casework samples such as blood, semen, saliva, hair, and trace DNA samples, including extremely low quantity samples. Due to its design, it can also produce full profiles with highly degraded samples often found in forensic casework. Concordance testing between three independent laboratories displayed reproducible results of consistent levels on varying types of simulated casework samples. With such high levels of sensitivity, specificity, consistency and reliability, this genotyping assay, as a core part of the IrisPlex system, operates in accordance with SWGDAM guidelines. Furthermore, as we demonstrated previously, the IrisPlex eye colour prediction system provides reliable results without the need for knowledge on the bio-geographic ancestry of the sample donor. Hence, the IrisPlex system, with its model-based prediction probability estimation of blue and brown human eye colour, represents a useful tool for immediate application in accredited forensic laboratories, to be used for forensic intelligence in tracing unknown individuals from crime scene samples. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
2013-01-01
Background In recent years response rates on telephone surveys have been declining. Rates for the behavioral risk factor surveillance system (BRFSS) have also declined, prompting the use of new methods of weighting and the inclusion of cell phone sampling frames. A number of scholars and researchers have conducted studies of the reliability and validity of the BRFSS estimates in the context of these changes. As the BRFSS makes changes in its methods of sampling and weighting, a review of reliability and validity studies of the BRFSS is needed. Methods In order to assess the reliability and validity of prevalence estimates taken from the BRFSS, scholarship published from 2004–2011 dealing with tests of reliability and validity of BRFSS measures was compiled and presented by topics of health risk behavior. Assessments of the quality of each publication were undertaken using a categorical rubric. Higher rankings were achieved by authors who conducted reliability tests using repeated test/retest measures, or who conducted tests using multiple samples. A similar rubric was used to rank validity assessments. Validity tests which compared the BRFSS to physical measures were ranked higher than those comparing the BRFSS to other self-reported data. Literature which undertook more sophisticated statistical comparisons was also ranked higher. Results Overall findings indicated that BRFSS prevalence rates were comparable to other national surveys which rely on self-reports, although specific differences are noted for some categories of response. BRFSS prevalence rates were less similar to surveys which utilize physical measures in addition to self-reported data. There is very little research on reliability and validity for some health topics, but a great deal of information supporting the validity of the BRFSS data for others. Conclusions Limitations of the examination of the BRFSS were due to question differences among surveys used as comparisons, as well as mode of data collection differences. As the BRFSS moves to incorporating cell phone data and changing weighting methods, a review of reliability and validity research indicated that past BRFSS landline only data were reliable and valid as measured against other surveys. New analyses and comparisons of BRFSS data which include the new methodologies and cell phone data will be needed to ascertain the impact of these changes on estimates in the future. PMID:23522349
A miniaturised image based fluorescence detection system for point-of-care-testing of cocaine abuse
NASA Astrophysics Data System (ADS)
Walczak, Rafał; Krüger, Jan; Moynihan, Shane
2015-08-01
In this paper, we describe a miniaturised image-based fluorescence detection system and demonstrate its viability as a highly sensitive tool for point-of-care-analysis of drugs of abuse in human sweat with a focus on monitor individuals for drugs of abuse. Investigations of miniaturised and low power optoelectronic configurations and methodologies for real-time image analysis were successfully carried out. The miniaturised fluorescence detection system was validated against a reference detection system under controlled laboratory conditions by analysing spiked sweat samples in dip stick and then strip with sample pad. As a result of the validation studies, a 1 ng mL-1 limit of detection of cocaine in sweat and full agreement of test results with the reference detection system can be reported. Results of the investigations open the way towards a detection system that integrates a hand-held fluorescence reader and a wearable skinpatch, and which can collect and in situ analyse sweat for the presence of cocaine at any point for up to tenths hours.
Studer, Joseph; Baggio, Stéphanie; Mohler-Kuo, Meichun; Daeppen, Jean-Bernard; Gmel, Gerhard
2016-03-01
The Behavioural Inhibition System/Behavioural Activation System scales (BIS/BAS scales) constitute one of the most prominent questionnaires to assess individual differences in sensitivity to punishment and reward. However, some studies questioned its validity, especially that of the French and German translations. The aim of the present study was to re-evaluate the psychometric characteristics of the BIS/BAS scales in a large sample of French- and German-speaking young Swiss men (N = 5872). Results showed that factor structures previously found in the literature did not meet the standards of fit. Nine items had to be removed to achieve adequate fit statistics in confirmatory factor analysis, yielding a shortened version with four factors: one BIS factor comprising five items and three BAS factors, namely Reward Reactivity, Drive and Fun Seeking, each comprising two items. Convergent validity and group invariance analyses suggest that the shortened BIS/BAS scales constitute a valid and reliable instrument. Researchers interested in assessing individual differences in BIS and BAS reactivity in French- and German-speaking individuals should avoid using the BIS/BAS scales as originally specified. The shortened version may be a sound alternative at least in samples of young adults. Its shorter format may be particularly suited for surveys with constraints on questionnaire length.
Psychometric Evaluation of the PROMIS Fatigue-Short Form Across Diverse Populations
Ameringer, Suzanne; Elswick, R. K.; Menzies, Victoria; Robins, Jo Lynne; Starkweather, Angela; Walter, Jeanne; Gentry, Amanda Elswick; Jallo, Nancy
2016-01-01
Background The need for reliable, valid tools to measure patient-reported outcomes (PROs) is critical for both research and for evaluating treatment effects in practice. The Patient Reported Outcome Measurement Information System (PROMIS) Fatigue-Short Form v1.0 –Fatigue 7a (PROMIS F-SF) has had limited psychometric evaluation in various populations. Objectives The aim of the study is to examine psychometric properties of PROMIS F-SF item responses across various populations. Methods Data from five studies with common data elements were used in this secondary analysis. Samples from patients with fibromyalgia, sickle cell disease, cardiometabolic risk, pregnancy, and healthy controls were used. Reliability was estimated using Cronbach’s alpha. Dimensionality was evaluated with confirmatory factor analysis. Concurrent validity was evaluated by examining Pearson’s correlations between scores from the PROMIS F-SF, the Multidimensional Fatigue Symptom Inventory-Short Form (MFSI-SF), and the Brief Fatigue Inventory (BFI). Discriminant validity was evaluated by examining Pearson’s correlations between scores on the PROMIS F-SF and measures of stress and depressive symptoms. Known groups validity was assessed by comparing PROMIS F-SH scores in the clinical samples to healthy controls. Results Reliability of PROMIS F-SF scores was adequate across samples, ranging from .72 in the pregnancy sample to .88 in healthy controls. Unidimensionality was supported in each sample. Concurrent validity was strong; across the groups, correlations with scores on the MFSI-SF and BFI ranged from .60–.85. Correlations of the PROMIS-SF with measures of stress and depressive mood were moderate to strong, ranging from .37–.64. PROMIS F-SF scores were significantly higher in clinical samples, compared to healthy controls. Discussion Reliability and validity of the PROMIS F-SF were acceptable. The PROMIS F-SF is a suitable measure of fatigue across the four diverse clinical populations included in the analysis. PMID:27362514
Salceda, Susana; Barican, Arnaldo; Buscaino, Jacklyn; Goldman, Bruce; Klevenberg, Jim; Kuhn, Melissa; Lehto, Dennis; Lin, Frank; Nguyen, Phong; Park, Charles; Pearson, Francesca; Pittaro, Rick; Salodkar, Sayali; Schueren, Robert; Smith, Corey; Troup, Charles; Tsou, Dean; Vangbo, Mattias; Wunderle, Justus; King, David
2017-05-01
The RapidHIT ® ID is a fully automated sample-to-answer system for short tandem repeat (STR)-based human identification. The RapidHIT ID has been optimized for use in decentralized environments and processes presumed single source DNA samples, generating Combined DNA Index System (CODIS)-compatible DNA profiles in less than 90min. The system is easy to use, requiring less than one minute of hands-on time. Profiles are reviewed using centralized linking software, RapidLINK™ (IntegenX, Pleasanton, CA), a software tool designed to collate DNA profiles from single or multiple RapidHIT ID systems at different geographic locations. The RapidHIT ID has been designed to employ GlobalFiler ® Express and AmpFLSTR ® NGMSElect™, Thermo Fisher Scientific (Waltham, MA) STR chemistries. The Developmental Validation studies were performed using GlobalFiler ® Express with single source reference samples according to Scientific Working Group for DNA Analysis Methods guidelines. These results show that multiple RapidHIT ID systems networked with RapidLINK software form a highly reliable system for wide-scale deployment in locations such as police booking stations and border crossings enabling real-time testing of arrestees, potential human trafficking victims, and other instances where rapid turnaround is essential. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.
Bertrand-Krajewski, J L; Bardin, J P; Mourad, M; Béranger, Y
2003-01-01
Assessing the functioning and the performance of urban drainage systems on both rainfall event and yearly time scales is usually based on online measurements of flow rates and on samples of influent effluent for some rainfall events per year. In order to draw pertinent scientific and operational conclusions from the measurement results, it is absolutely necessary to use appropriate methods and techniques in order to i) calibrate sensors and analytical methods, ii) validate raw data, iii) evaluate measurement uncertainties, iv) evaluate the number of rainfall events to sample per year in order to determine performance indicator with a given uncertainty. Based an previous work, the paper gives a synthetic review of required and techniques, and illustrates their application to storage and settling tanks. Experiments show that, controlled and careful experimental conditions, relative uncertainties are about 20% for flow rates in sewer pipes, 6-10% for volumes, 25-35% for TSS concentrations and loads, and 18-276% for TSS removal rates. In order to evaluate the annual pollutant interception efficiency of storage and settling tanks with a given uncertainty, efforts should first be devoted to decrease the sampling uncertainty by increasing the number of sampled events.
Tucker, Valerie C; Hopwood, Andrew J; Sprecher, Cynthia J; McLaren, Robert S; Rabbach, Dawn R; Ensenberger, Martin G; Thompson, Jonelle M; Storts, Douglas R
2011-11-01
In response to the ENFSI and EDNAP groups' call for new STR multiplexes for Europe, Promega(®) developed a suite of four new DNA profiling kits. This paper describes the developmental validation study performed on the PowerPlex(®) ESI 16 (European Standard Investigator 16) and the PowerPlex(®) ESI 17 Systems. The PowerPlex(®) ESI 16 System combines the 11 loci compatible with the UK National DNA Database(®), contained within the AmpFlSTR(®) SGM Plus(®) PCR Amplification Kit, with five additional loci: D2S441, D10S1248, D22S1045, D1S1656 and D12S391. The multiplex was designed to reduce the amplicon size of the loci found in the AmpFlSTR(®) SGM Plus(®) kit. This design facilitates increased robustness and amplification success for the loci used in the national DNA databases created in many countries, when analyzing degraded DNA samples. The PowerPlex(®) ESI 17 System amplifies the same loci as the PowerPlex(®) ESI 16 System, but with the addition of a primer pair for the SE33 locus. Tests were designed to address the developmental validation guidelines issued by the Scientific Working Group on DNA Analysis Methods (SWGDAM), and those of the DNA Advisory Board (DAB). Samples processed include DNA mixtures, PCR reactions spiked with inhibitors, a sensitivity series, and 306 United Kingdom donor samples to determine concordance with data generated with the AmpFlSTR(®) SGM Plus(®) kit. Allele frequencies from 242 white Caucasian samples collected in the United Kingdom are also presented. The PowerPlex(®) ESI 16 and ESI 17 Systems are robust and sensitive tools, suitable for the analysis of forensic DNA samples. Full profiles were routinely observed with 62.5pg of a fully heterozygous single source DNA template. This high level of sensitivity was found to impact on mixture analyses, where 54-86% of unique minor contributor alleles were routinely observed in a 1:19 mixture ratio. Improved sensitivity combined with the robustness afforded by smaller amplicons has substantially improved the quantity of data obtained from degraded samples, and the improved chemistry confers exceptional tolerance to high levels of laboratory prepared inhibitors. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Parra, Macarena; Jung, Jimmy; Almeida, Eduardo; Boone, Travis; Schonfeld, Julie; Tran, Luan
2016-01-01
The WetLab-2 system was developed by NASA Ames Research Center to offer new capabilities to researchers. The system can lyse cells and extract RNA (Ribonucleic Acid) on-orbit from different sample types ranging from microbial cultures to animal tissues. The purified RNA can then either be stabilized for return to Earth or can be used to conduct on-orbit quantitative Reverse Transcriptase PCR (Polymerase Chain Reaction) (qRT-PCR) analysis without the need for sample return. The qRT-PCR results can be downlinked to the ground a few hours after the completion of the run. The validation flight of the WetLab-2 system launched on SpaceX-8 on April 8, 2016. On orbit operations started on April 15th with system setup and was followed by three quantitative PCR runs using an E. coli genomic DNA template pre-loaded at three different concentrations. These runs were designed to discern if quantitative PCR functions correctly in microgravity and if the data is comparable to that from the ground control runs. The flight data showed no significant differences compared to the ground data though there was more variability in the values, this was likely due to the numerous small bubbles observed. The capability of the system to process samples and purify RNA was then validated using frozen samples prepared on the ground. The flight data for both E. coli and mouse liver clearly shows that RNA was successfully purified by our system. The E. coli qRT-PCR run showed successful singleplex, duplex and triplex capability. Data showed high variability in the resulting Cts (Cycle Thresholds [for the PCR]) likely due to bubble formation and insufficient mixing during the procedure run. The mouse liver qRT-PCR run had successful singleplex and duplex reactions and the variability was slightly better as the mixing operation was improved. The ability to purify and stabilize RNA and to conduct qRT-PCR on-orbit is an important step towards utilizing the ISS as a National Laboratory facility. The ability to get on-orbit data will provide investigators with the opportunity to adjust experimental parameters in real time without the need for sample return and re-flight. The WetLab-2 Project is supported by the Research Integration Office in the ISS Program.
González-Chordá, Víctor M; Mena-Tudela, Desirée; Salas-Medina, Pablo; Cervera-Gasch, Agueda; Orts-Cortés, Isabel; Maciá-Soler, Loreto
2016-02-01
Writing a bachelor thesis (BT) is the last step to obtain a nursing degree. In order to perform an effective assessment of a nursing BT, certain reliable and valid tools are required. To develop and validate a 3-rubric system (drafting process, dissertation, and viva) to assess final year nursing students' BT. A multi-disciplinary study of content validity and psychometric properties. The study was carried out between December 2014 and July 2015. Nursing Degree at Universitat Jaume I. Spain. Eleven experts (9 nursing professors and 2 education professors from 6 different universities) took part in the development and content validity stages. Fifty-two theses presented during the 2014-2015 academic year were included by consecutive sampling of cases in order to study the psychometric properties. First, a group of experts was created to validate the content of the assessment system based on three rubrics (drafting process, dissertation, and viva). Subsequently, a reliability and validity study of the rubrics was carried out on the 52 theses presented during the 2014-2015 academic year. The BT drafting process rubric has 8 criteria (S-CVI=0.93; α=0.837; ICC=0.614), the dissertation rubric has 7 criteria (S-CVI=0.9; α=0.893; ICC=0.74), and the viva rubric has 4 criteria (S-CVI=0.86; α=8.16; ICC=0.895). A nursing BT assessment system based on three rubrics (drafting process, dissertation, and viva) has been validated. This system may be transferred to other nursing degrees or degrees from other academic areas. It is necessary to continue with the validation process taking into account factors that may affect the results obtained. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Lu, Zenghai; Matcher, Stephen J.
2013-03-01
We report on a new calibration technique that permits the accurate extraction of sample Jones matrix and hence fast-axis orientation by using fiber-based polarization-sensitive optical coherence tomography (PS-OCT) that is completely based on non polarization maintaining fiber such as SMF-28. In this technique, two quarter waveplates are used to completely specify the parameters of the system fibers in the sample arm so that the Jones matrix of the sample can be determined directly. The device was validated on measurements of a quarter waveplate and an equine tendon sample by a single-mode fiber-based swept-source PS-OCT system.
Debray, Thomas P A; Vergouwe, Yvonne; Koffijberg, Hendrik; Nieboer, Daan; Steyerberg, Ewout W; Moons, Karel G M
2015-03-01
It is widely acknowledged that the performance of diagnostic and prognostic prediction models should be assessed in external validation studies with independent data from "different but related" samples as compared with that of the development sample. We developed a framework of methodological steps and statistical methods for analyzing and enhancing the interpretation of results from external validation studies of prediction models. We propose to quantify the degree of relatedness between development and validation samples on a scale ranging from reproducibility to transportability by evaluating their corresponding case-mix differences. We subsequently assess the models' performance in the validation sample and interpret the performance in view of the case-mix differences. Finally, we may adjust the model to the validation setting. We illustrate this three-step framework with a prediction model for diagnosing deep venous thrombosis using three validation samples with varying case mix. While one external validation sample merely assessed the model's reproducibility, two other samples rather assessed model transportability. The performance in all validation samples was adequate, and the model did not require extensive updating to correct for miscalibration or poor fit to the validation settings. The proposed framework enhances the interpretation of findings at external validation of prediction models. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
McDonald, Linda S; Panozzo, Joseph F; Salisbury, Phillip A; Ford, Rebecca
2016-01-01
Field peas (Pisum sativum L.) are generally traded based on seed appearance, which subjectively defines broad market-grades. In this study, we developed an objective Linear Discriminant Analysis (LDA) model to classify market grades of field peas based on seed colour, shape and size traits extracted from digital images. Seeds were imaged in a high-throughput system consisting of a camera and laser positioned over a conveyor belt. Six colour intensity digital images were captured (under 405, 470, 530, 590, 660 and 850nm light) for each seed, and surface height was measured at each pixel by laser. Colour, shape and size traits were compiled across all seed in each sample to determine the median trait values. Defective and non-defective seed samples were used to calibrate and validate the model. Colour components were sufficient to correctly classify all non-defective seed samples into correct market grades. Defective samples required a combination of colour, shape and size traits to achieve 87% and 77% accuracy in market grade classification of calibration and validation sample-sets respectively. Following these results, we used the same colour, shape and size traits to develop an LDA model which correctly classified over 97% of all validation samples as defective or non-defective.
McDonald, Linda S.; Panozzo, Joseph F.; Salisbury, Phillip A.; Ford, Rebecca
2016-01-01
Field peas (Pisum sativum L.) are generally traded based on seed appearance, which subjectively defines broad market-grades. In this study, we developed an objective Linear Discriminant Analysis (LDA) model to classify market grades of field peas based on seed colour, shape and size traits extracted from digital images. Seeds were imaged in a high-throughput system consisting of a camera and laser positioned over a conveyor belt. Six colour intensity digital images were captured (under 405, 470, 530, 590, 660 and 850nm light) for each seed, and surface height was measured at each pixel by laser. Colour, shape and size traits were compiled across all seed in each sample to determine the median trait values. Defective and non-defective seed samples were used to calibrate and validate the model. Colour components were sufficient to correctly classify all non-defective seed samples into correct market grades. Defective samples required a combination of colour, shape and size traits to achieve 87% and 77% accuracy in market grade classification of calibration and validation sample-sets respectively. Following these results, we used the same colour, shape and size traits to develop an LDA model which correctly classified over 97% of all validation samples as defective or non-defective. PMID:27176469
Data Validation Package - July 2016 Groundwater Sampling at the Gunnison, Colorado, Disposal Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Linard, Joshua; Campbell, Sam
Groundwater sampling at the Gunnison, Colorado, Disposal Site is conducted every 5 years to monitor disposal cell performance. During this event, samples were collected from eight monitoring wells as specified in the 1997 Long-Term Surveillance Plan for the Gunnison, Colorado, Disposal Site. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for US Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and analysis-plan-us-department-energy-office-legacy-management-sites). Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. A duplicate sample was collected from location 0723. Water levels were measured at all monitoring wells thatmore » were sampled and seven additional wells. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. No issues were identified during the data validation process that require additional action or follow-up.« less
Forbes, L B; Hill, D E; Parker, S; Tessaro, S V; Gamble, H R; Gajadhar, A A
2008-03-01
A tissue digestion assay using a double separatory funnel procedure for the detection of Trichinella larvae in horse meat was validated for application in food safety programs and trade. The assay consisted of a pepsin-HCl digestion step to release larvae from muscle tissue and two sequential sedimentation steps in separatory funnels to recover and concentrate larvae for detection with a stereomicroscope. With defined critical control points, the assay was conducted within a quality assurance system compliant with International Organization for Standardization-International Electrotechnical Commission (ISO/IEC) 17025 guidelines. Samples used in the validation were obtained from horses experimentally infected with Trichinella spiralis to obtain a range of muscle larvae densities. One-, 5-, and 10-g samples of infected tissue were combined with 99, 95, and 90 g, respectively, of known negative horse tissue to create a 100-g sample for testing. Samples of 5 and 10 g were more likely to be positive than were 1-g samples when larval densities were less than three larvae per gram (lpg). This difference is important because ingested meat with 1 lpg is considered the threshold for clinical disease in humans. Using a 5-g sample size, all samples containing 1.3 to 2 lpg were detected, and 60 to 100% of samples with infected horse meat containing 0.1 to 0.7 lpg were detected. In this study, the double separatory funnel digestion assay was efficient and reliable for its intended use in food safety and trade. This procedure is the only digestion assay for Trichinella in horse meat that has been validated as consistent and effective at critical levels of sensitivity.
Synthesis of Common Arabic Handwritings to Aid Optical Character Recognition Research.
Dinges, Laslo; Al-Hamadi, Ayoub; Elzobi, Moftah; El-Etriby, Sherif
2016-03-11
Document analysis tasks such as pattern recognition, word spotting or segmentation, require comprehensive databases for training and validation. Not only variations in writing style but also the used list of words is of importance in the case that training samples should reflect the input of a specific area of application. However, generation of training samples is expensive in the sense of manpower and time, particularly if complete text pages including complex ground truth are required. This is why there is a lack of such databases, especially for Arabic, the second most popular language. However, Arabic handwriting recognition involves different preprocessing, segmentation and recognition methods. Each requires particular ground truth or samples to enable optimal training and validation, which are often not covered by the currently available databases. To overcome this issue, we propose a system that synthesizes Arabic handwritten words and text pages and generates corresponding detailed ground truth. We use these syntheses to validate a new, segmentation based system that recognizes handwritten Arabic words. We found that a modification of an Active Shape Model based character classifiers-that we proposed earlier-improves the word recognition accuracy. Further improvements are achieved, by using a vocabulary of the 50,000 most common Arabic words for error correction.
Synthesis of Common Arabic Handwritings to Aid Optical Character Recognition Research
Dinges, Laslo; Al-Hamadi, Ayoub; Elzobi, Moftah; El-etriby, Sherif
2016-01-01
Document analysis tasks such as pattern recognition, word spotting or segmentation, require comprehensive databases for training and validation. Not only variations in writing style but also the used list of words is of importance in the case that training samples should reflect the input of a specific area of application. However, generation of training samples is expensive in the sense of manpower and time, particularly if complete text pages including complex ground truth are required. This is why there is a lack of such databases, especially for Arabic, the second most popular language. However, Arabic handwriting recognition involves different preprocessing, segmentation and recognition methods. Each requires particular ground truth or samples to enable optimal training and validation, which are often not covered by the currently available databases. To overcome this issue, we propose a system that synthesizes Arabic handwritten words and text pages and generates corresponding detailed ground truth. We use these syntheses to validate a new, segmentation based system that recognizes handwritten Arabic words. We found that a modification of an Active Shape Model based character classifiers—that we proposed earlier—improves the word recognition accuracy. Further improvements are achieved, by using a vocabulary of the 50,000 most common Arabic words for error correction. PMID:26978368
Nurses views on accepting the creation of a nurses’ health monitoring system
Rasoulzadeh, Nasrin; Abbaszadeh, Abbas; Zaefarian, Reza; Khounraz, Fariba
2017-01-01
Background Nurses’ health is often accompanied by various dangers due to the nature of their career. Therefore, it is required to monitor their health. Based on designing any system, users’ views should be investigated relative to the usefulness, necessity and acceptance of the system. Then, a designing and implementing process is conducted. Objective To investigate nurses’ views on accepting the creation of a Nurses’ Health Monitoring System. Methods This cross-sectional study was conducted in 2015. Sample size was 586 nurses of Shahid Beheshti University of Medical Sciences. Sampling was conducted using multi-stage random sampling method. Research tool was a two-section researcher-made questionnaire. In the first section, demographic data were studied and in the second section, a twelve-item questionnaire was presented based on technology acceptance model. Five-item questions were regulated on perceived usefulness (PU) and perceived ease of use (PEU) and views towards creating this system. Validity of the questionnaire was approved by content validity and content validity index and its reliability was approved by Cronbach’s alpha. Data were analyzed using SPSS16 and descriptive statistics (frequency distribution, percentage, mean). Results The majority of participants (75.3%) were females between 25–35 years of age (44.4%) and (58.2%) were married. Mean work experience was 11.5±8.19. Mean perceived usefulness (PU) (17.36±2.66) and perceived ease of use (PEU) (16.75±2.65) and views towards using a Nurses’ Health Monitoring System was (16.220±3.05). Conclusion Over two-thirds of nurses demonstrated perceived usefulness and perceived ease of use as well as positive views towards creating a nurses’ health monitoring system. It is recommended to design and implement a nurses’ health monitoring system based on local culture of Iranian nurses using IT in the health sector. PMID:28713521
Developmental validation of the PowerPlex(®) 21 System.
Ensenberger, Martin G; Hill, Carolyn R; McLaren, Robert S; Sprecher, Cynthia J; Storts, Douglas R
2014-03-01
The PowerPlex(®) 21 System is a STR multiplex that has been optimized for casework samples while still being capable of database workflows including direct amplification. The loci included in the multiplex offer increasing overlap with core loci used in different countries and regions throughout the world. The PowerPlex(®) 21 System contains D1S1656, D2S1338, D3S1358, D5S818, D6S1043, D7S820, D8S1179, D12S391, D13S317, D16S539, D18S51, D19S433, D21S11, Amelogenin, CSF1PO, FGA, Penta D, Penta E, TH01, TPOX, and vWA. These loci represent all 13 core CODIS loci in addition to loci commonly used in Asia and Europe. A developmental validation study was completed to document performance capabilities and limitations of the PowerPlex(®) 21 System. Data from this validation work served as the basis for the following conclusions: genotyping of single-source samples was reliable across a range of template DNA concentrations with >95% alleles called at 50 pg. Direct amplification of samples from FTA(®) storage cards was successfully performed using the reagents provided with the system and modified cycling protocols provided in the technical manual. Mixture analysis showed that over 95% of minor alleles were detected at 1:9 ratios. Reaction conditions including volume and annealing temperature as well as the concentrations of primers, DNA polymerase, magnesium, and Master Mix were shown to be optimal and able to withstand moderate variations without affecting system performance. Reproducible results were generated by different users at different sites. Finally, concordance studies showed consistent results when comparing the PowerPlex(®) 21 System with other commercially available STR-genotyping systems. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Development of an integrated semi-automated system for in vitro pharmacodynamic modelling.
Wang, Liangsu; Wismer, Michael K; Racine, Fred; Conway, Donald; Giacobbe, Robert A; Berejnaia, Olga; Kath, Gary S
2008-11-01
The aim of this study was to develop an integrated system for in vitro pharmacodynamic modelling of antimicrobials with greater flexibility, easier control and better accuracy than existing in vitro models. Custom-made bottle caps, fittings, valve controllers and a modified bench-top shaking incubator were used. A temperature-controlled automated sample collector was built. Computer software was developed to manage experiments and to control the entire system including solenoid pinch valves, peristaltic pumps and the sample collector. The system was validated by pharmacokinetic simulations of linezolid 600 mg infusion. The antibacterial effect of linezolid against multiple Staphylococcus aureus strains was also studied in this system. An integrated semi-automated bench-top system was built and validated. The temperature-controlled automated sample collector allowed unattended collection and temporary storage of samples. The system software reduced the labour necessary for many tasks and also improved the timing accuracy for performing simultaneous actions in multiple parallel experiments. The system was able to simulate human pharmacokinetics of linezolid 600 mg intravenous infusion accurately. A pharmacodynamic study of linezolid against multiple S. aureus strains with a range of MICs showed that the required 24 h free drug AUC/MIC ratio was approximately 30 in order to keep the organism counts at the same level as their initial inoculum and was about > or = 68 in order to achieve > 2 log(10) cfu/mL reduction in the in vitro model. The integrated semi-automated bench-top system provided the ability to overcome many of the drawbacks of existing in vitro models. It can be used for various simple or complicated pharmacokinetic/pharmacodynamic studies efficiently and conveniently.
Snodgrass, Ryan; Gardner, Andrea; Jiang, Li; Fu, Cheng; Cesarman, Ethel; Erickson, David
2016-01-01
Resource-limited settings present unique engineering challenges for medical diagnostics. Diagnosis is often needed for those unable to reach central healthcare systems, making portability and independence from traditional energy infrastructure essential device parameters. In 2014, our group presented a microfluidic device that performed a solar-powered variant of the polymerase chain reaction, which we called solar thermal PCR. In this work, we expand on our previous effort by presenting an integrated, portable, solar thermal PCR system targeted towards the diagnosis of Kaposi’s sarcoma. We call this system KS-Detect, and we now report the system’s performance as a diagnostic tool using pseudo-biopsy samples made from varying concentrations of human lymphoma cell lines positive for the KS herpesvirus (KSHV). KS-Detect achieved 83% sensitivity and 70% specificity at high (≥10%) KSHV+ cell concentrations when diagnosing pseudo-biopsy samples by smartphone image. Using histology, we confirm that our prepared pseudo-biopsies contain similar KSHV+ cell concentrations as human biopsies positive for KS. Through our testing of samples derived from human cell lines, we validate KS-Detect as a viable, portable KS diagnostic tool, and we identify critical engineering considerations for future solar-thermal PCR devices. PMID:26799834
Challenges in validating the sterilisation dose for processed human amniotic membranes
NASA Astrophysics Data System (ADS)
Yusof, Norimah; Hassan, Asnah; Firdaus Abd Rahman, M. N.; Hamid, Suzina A.
2007-11-01
Most of the tissue banks in the Asia Pacific region have been using ionising radiation at 25 kGy to sterilise human tissues for save clinical usage. Under tissue banking quality system, any dose employed for sterilisation has to be validated and the validation exercise has to be a part of quality document. Tissue grafts, unlike medical items, are not produced in large number per each processing batch and tissues relatively have a different microbial population. A Code of Practice established by the International Atomic Energy Agency (IAEA) in 2004 offers several validation methods using smaller number of samples compared to ISO 11137 (1995), which is meant for medical products. The methods emphasise on bioburden determination, followed by sterility test on samples after they were exposed to verification dose for attaining of sterility assurance level (SAL) of 10 -1. This paper describes our experience in using the IAEA Code of Practice in conducting the validation exercise for substantiating 25 kGy as sterilisation dose for both air-dried amnion and those preserved in 99% glycerol.
Schimpf, Karen J.; Meek, Claudia C.; Leff, Richard D.; Phelps, Dale L.; Schmitz, Daniel J.; Cordle, Christopher T.
2015-01-01
Inositol is a six-carbon sugar alcohol and is one of nine biologically significant isomers of hexahydroxycyclohexane. Myo-inositol is the primary biologically active form and is present in higher concentrations in the fetus and newborn than in adults. It is currently being examined for the prevention of retinopathy of prematurity in newborn preterm infants. A robust method for quantifying myo-inositol (MI), D-chiro-inositol (DCI) and 1,5-anhydro-D-sorbitol (ADS) in very small-volume (25 μL) urine, blood serum and/or plasma samples was developed. Using a multiple-column, multiple mobile phase liquid chromatographic system with electrochemical detection, the method was validated with respect to (a) selectivity, (b) accuracy/recovery, (c) precision/reproducibility, (d) sensitivity, (e) stability and (f) ruggedness. The standard curve was linear and ranged from 0.5 to 30 mg/L for each of the three analytes. Above-mentioned performance measures were within acceptable limits described in the Food and Drug Administration’s Guidance for Industry: Bioanalytical Method Validation. The method was validated using blood serum and plasma collected using four common anticoagulants, and also by quantifying the accuracy and sensitivity of MI measured in simulated urine samples recovered from preterm infant diaper systems. The method performs satisfactorily measuring the three most common inositol isomers on 25 μL clinical samples of serum, plasma milk, and/or urine. Similar performance is seen testing larger volume samples of infant formulas and infant formula ingredients. MI, ADS and DCI may be accurately tested in urine samples collected from five different preterm infant diapers if the urine volume is greater than 2–5 mL. PMID:26010453
Bhat, Somanath; Polanowski, Andrea M; Double, Mike C; Jarman, Simon N; Emslie, Kerry R
2012-01-01
Recent advances in nanofluidic technologies have enabled the use of Integrated Fluidic Circuits (IFCs) for high-throughput Single Nucleotide Polymorphism (SNP) genotyping (GT). In this study, we implemented and validated a relatively low cost nanofluidic system for SNP-GT with and without Specific Target Amplification (STA). As proof of principle, we first validated the effect of input DNA copy number on genotype call rate using well characterised, digital PCR (dPCR) quantified human genomic DNA samples and then implemented the validated method to genotype 45 SNPs in the humpback whale, Megaptera novaeangliae, nuclear genome. When STA was not incorporated, for a homozygous human DNA sample, reaction chambers containing, on average 9 to 97 copies, showed 100% call rate and accuracy. Below 9 copies, the call rate decreased, and at one copy it was 40%. For a heterozygous human DNA sample, the call rate decreased from 100% to 21% when predicted copies per reaction chamber decreased from 38 copies to one copy. The tightness of genotype clusters on a scatter plot also decreased. In contrast, when the same samples were subjected to STA prior to genotyping a call rate and a call accuracy of 100% were achieved. Our results demonstrate that low input DNA copy number affects the quality of data generated, in particular for a heterozygous sample. Similar to human genomic DNA, a call rate and a call accuracy of 100% was achieved with whale genomic DNA samples following multiplex STA using either 15 or 45 SNP-GT assays. These calls were 100% concordant with their true genotypes determined by an independent method, suggesting that the nanofluidic system is a reliable platform for executing call rates with high accuracy and concordance in genomic sequences derived from biological tissue.
40 CFR 761.392 - Preparing validation study samples.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Preparing validation study samples..., AND USE PROHIBITIONS Comparison Study for Validating a New Performance-Based Decontamination Solvent Under § 761.79(d)(4) § 761.392 Preparing validation study samples. (a)(1) To validate a procedure to...
40 CFR 761.392 - Preparing validation study samples.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Preparing validation study samples..., AND USE PROHIBITIONS Comparison Study for Validating a New Performance-Based Decontamination Solvent Under § 761.79(d)(4) § 761.392 Preparing validation study samples. (a)(1) To validate a procedure to...
Validation of a new classification system for skin tears.
LeBlanc, Kimberly; Baranoski, Sharon; Holloway, Samantha; Langemo, Diane
2013-06-01
The aim of this study was to validate and establish reliability of the International Skin Tear classification system. A consensus panel of 12 internationally recognized key opinion leaders convened in 2011 to establish consensus statements on the prevention, prediction, assessment, and treatment of skin tears. Subsequently, a new skin tear classification system was proposed. The system was then tested for interrater and intrarater reliability between the experts before being tested more widely on a sample of 327 individuals from the United States, Canada, and Europe. The results of the study indicated a substantial level of agreement for the expert panel (Fleiss κ = 0.619; 2-month follow-up = 0.653). Intrarater reliability was high (Cohen κ = 0.877). Interrater reliability was moderate (Fleiss κ = 0.555) for healthcare professionals (n = 303) and fair for non-health professionals (Fleiss κ = 0.338; n = 24). This international study established the reliability and validity of a new classification system for skin tears.
Validation of the BESS TRS-P Structure with an Independent Sample of Teacher Ratings
ERIC Educational Resources Information Center
DiStefano, Christine; Greer, Fred; Liu, Jin
2016-01-01
The underlying structure of the Behavioral and Emotional Screening System, Teacher Rating Scale-Preschool was investigated with a replication sample. Ratings from more than 3,000 students were used and four alternative models were investigated. As with prior research, a bifactor model with four factors was identified. The results supported an…
BioMICADAS: Compact next generation AMS system for pharmaceutical science
NASA Astrophysics Data System (ADS)
Schulze-König, Tim; Dueker, Stephen R.; Giacomo, Jason; Suter, Martin; Vogel, John S.; Synal, Hans-Arno
2010-04-01
The next generation Accelerator Mass Spectrometer system specifically designed to address the needs of the growing pharmaceutical science market has passed validation testing. The system dubbed BioMICADAS is based on a previously developed compact carbon dating instrument, the MICADAS. Like its predecessor, it has an overall footprint of only 2.5 × 3 m 2 and uses a 200 kV high voltage platform for tandem based ion acceleration. The ion source can accommodate samples as graphite or gaseous CO 2. It is equipped with two independently operating vacuum locks, allowing continuous measurement sequence and providing a capacity of ˜20,000 samples per annum. A barcoded cathode tracking system allows data capture into Laboratory Information Management System (LIMS) for Good Laboratory Practices (GLP) regulated work. It can be housed in research laboratories alongside other complementary bioanalytical equipment and operated by general laboratory staff as the system is designed to be robust and user-friendly. The system has undergone rigorous validation over the range from 0.1 to 100 Modern Carbon, including accuracy, linearity, robustness, and precision experiments over the course of 7 months. It has been shipped and installed at the site of our collaborative partner, Vitalea Science in Davis, California. The installation process took ˜2 weeks from boxes to beam. The feasibility of the system to determine the absolute specific activity of biogenic samples was also shown by using the method of isotopic dilution.
Baietto, Lorena; D'Avolio, Antonio; Marra, Cristina; Simiele, Marco; Cusato, Jessica; Pace, Simone; Ariaudo, Alessandra; De Rosa, Francesco Giuseppe; Di Perri, Giovanni
2012-11-01
Therapeutic drug monitoring (TDM) of triazoles is widely used in clinical practice to optimize therapy. TDM is limited by technical problems and cost considerations, such as sample storage and dry-ice shipping. We aimed to develop and validate a new method to analyse itraconazole, posaconazole and voriconazole in plasma spotted on dry sample spot devices (DSSDs) and to quantify them by an HPLC system. Extraction from DSSDs was done using n-hexane/ethyl acetate and ammonia solution. Samples were analysed using HPLC with mass spectrometry (HPLC-MS). Accuracy and precision were assayed by inter- and intra-day validation. The stability of triazoles in plasma spotted on DSSDs was investigated at room temperature for 1 month. The method was compared with a validated standard HPLC method for quantification of triazoles in human plasma. Mean inter- and intra-day accuracy and precision were <15% for all compounds. Triazoles were stable for 2 weeks at room temperature. The method was linear (r(2) > 0.999) in the range 0.031-8 mg/L for itraconazole and posaconazole, and 0.058-15 mg/L for voriconazole. High sensitivity was observed; limits of detection were 0.008, 0.004 and 0.007 mg/L for itraconazole, posaconazole and voriconazole, respectively. A high degree of correlation (r(2) > 0.94) was obtained between the DSSD method and the standard method of analysis. The method that we developed and validated to quantify triazoles in human plasma spotted on DSSDs is accurate and precise. It overcomes problems related to plasma sample storage and shipment, allowing TDM to be performed in a cheaper and safer manner.
Validation of the French version of the Acceptability E-scale (AES) for mental E-health systems.
Micoulaud-Franchi, Jean-Arthur; Sauteraud, Alain; Olive, Jérôme; Sagaspe, Patricia; Bioulac, Stéphanie; Philip, Pierre
2016-03-30
Despite the increasing use of E-health systems for mental-health organizations, there is a lack of psychometric tools to evaluate their acceptability by patients with mental disorders. Thus, this study aimed to translate and validate a French version of the Acceptability E-scale (AES), a 6-item self-reported questionnaire that evaluates the extent to which patients find E-health systems acceptable. A forward-backward translation of the AES was performed. The psychometric properties of the French AES version, with construct validity, internal structural validity and external validity (Pearson's coefficient between AES scores and depression symptoms on the Beck Depression Inventory II) were analyzed. In a sample of 178 patients (mean age=46.51 years, SD=12.91 years), the validation process revealed satisfactory psychometric properties: factor analysis revealed two factors: "Satisfaction" (3 items) and "Usability" (3 items) and Cronbach's alpha was 0.7. No significant relation was found between AES scores and depression symptoms. The French version of the AES revealed a two-factor scale that differs from the original version. In line with the importance of acceptability in mental health and with a view to E-health systems for patients with mental disorders, the use of the AES in psychiatry may provide important information on acceptability (i.e., satisfaction and usability). Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Palmer, L; Farrar, A R; Valle, M; Ghahary, N; Panella, M; DeGraw, D
2000-05-01
Identification and evaluation of child sexual abuse is an integral task for clinicians. To aid these processes, it is necessary to have reliable and valid psychological measures. This is an investigation of the clinical validity and use of the House-Tree-Person (HTP) projective drawing, a widely used diagnostic tool, in the assessment of child sexual abuse. HTP drawings were collected archivally from a sample of sexually abused children (n = 47) and a nonabused comparison sample (n = 82). The two samples were grossly matched for gender, ethnicity, age, and socioeconomic status. The protocols were scored using a quantitative scoring system. The data were analyzed using a discriminant function analysis. Group membership could not be predicted based on a total HTP score.
NASA Astrophysics Data System (ADS)
Wagner, David R.; Holmgren, Per; Skoglund, Nils; Broström, Markus
2018-06-01
The design and validation of a newly commissioned entrained flow reactor is described in the present paper. The reactor was designed for advanced studies of fuel conversion and ash formation in powder flames, and the capabilities of the reactor were experimentally validated using two different solid biomass fuels. The drop tube geometry was equipped with a flat flame burner to heat and support the powder flame, optical access ports, a particle image velocimetry (PIV) system for in situ conversion monitoring, and probes for extraction of gases and particulate matter. A detailed description of the system is provided based on simulations and measurements, establishing the detailed temperature distribution and gas flow profiles. Mass balance closures of approximately 98% were achieved by combining gas analysis and particle extraction. Biomass fuel particles were successfully tracked using shadow imaging PIV, and the resulting data were used to determine the size, shape, velocity, and residence time of converting particles. Successful extractive sampling of coarse and fine particles during combustion while retaining their morphology was demonstrated, and it opens up for detailed time resolved studies of rapid ash transformation reactions; in the validation experiments, clear and systematic fractionation trends for K, Cl, S, and Si were observed for the two fuels tested. The combination of in situ access, accurate residence time estimations, and precise particle sampling for subsequent chemical analysis allows for a wide range of future studies, with implications and possibilities discussed in the paper.
Appropriate time scales for nonlinear analyses of deterministic jump systems
NASA Astrophysics Data System (ADS)
Suzuki, Tomoya
2011-06-01
In the real world, there are many phenomena that are derived from deterministic systems but which fluctuate with nonuniform time intervals. This paper discusses the appropriate time scales that can be applied to such systems to analyze their properties. The financial markets are an example of such systems wherein price movements fluctuate with nonuniform time intervals. However, it is common to apply uniform time scales such as 1-min data and 1-h data to study price movements. This paper examines the validity of such time scales by using surrogate data tests to ascertain whether the deterministic properties of the original system can be identified from uniform sampled data. The results show that uniform time samplings are often inappropriate for nonlinear analyses. However, for other systems such as neural spikes and Internet traffic packets, which produce similar outputs, uniform time samplings are quite effective in extracting the system properties. Nevertheless, uniform samplings often generate overlapping data, which can cause false rejections of surrogate data tests.
Jiang, Jia-Jia; Duan, Fa-Jie; Li, Yan-Chao; Hua, Xiang-Ning
2014-03-01
Synchronization sampling is very important in underwater towed array system where every acquisition node (AN) samples analog signals by its own analog-digital converter (ADC). In this paper, a simple and effective synchronization sampling method is proposed to ensure synchronized operation among different ANs of the underwater towed array system. We first present a master-slave synchronization sampling model, and then design a high accuracy phase-locked loop to synchronize all delta-sigma ADCs to a reference clock. However, when the master-slave synchronization sampling model is used, both the time-delay (TD) of messages traveling along the wired transmission medium and the jitter of the clocks will bring out synchronization sampling error (SSE). Therefore, a simple method is proposed to estimate and compensate the TD of the messages transmission, and then another effective method is presented to overcome the SSE caused by the jitter of the clocks. An experimental system with three ANs is set up, and the related experimental results verify the validity of the synchronization sampling method proposed in this paper.
NASA Astrophysics Data System (ADS)
Jiang, Jia-Jia; Duan, Fa-Jie; Li, Yan-Chao; Hua, Xiang-Ning
2014-03-01
Synchronization sampling is very important in underwater towed array system where every acquisition node (AN) samples analog signals by its own analog-digital converter (ADC). In this paper, a simple and effective synchronization sampling method is proposed to ensure synchronized operation among different ANs of the underwater towed array system. We first present a master-slave synchronization sampling model, and then design a high accuracy phase-locked loop to synchronize all delta-sigma ADCs to a reference clock. However, when the master-slave synchronization sampling model is used, both the time-delay (TD) of messages traveling along the wired transmission medium and the jitter of the clocks will bring out synchronization sampling error (SSE). Therefore, a simple method is proposed to estimate and compensate the TD of the messages transmission, and then another effective method is presented to overcome the SSE caused by the jitter of the clocks. An experimental system with three ANs is set up, and the related experimental results verify the validity of the synchronization sampling method proposed in this paper.
Preliminary experiments on pharmacokinetic diffuse fluorescence tomography of CT-scanning mode
NASA Astrophysics Data System (ADS)
Zhang, Yanqi; Wang, Xin; Yin, Guoyan; Li, Jiao; Zhou, Zhongxing; Zhao, Huijuan; Gao, Feng; Zhang, Limin
2016-10-01
In vivo tomographic imaging of the fluorescence pharmacokinetic parameters in tissues can provide additional specific and quantitative physiological and pathological information to that of fluorescence concentration. This modality normally requires a highly-sensitive diffuse fluorescence tomography (DFT) working in dynamic way to finally extract the pharmacokinetic parameters from the measured pharmacokinetics-associated temporally-varying boundary intensity. This paper is devoted to preliminary experimental validation of our proposed direct reconstruction scheme of instantaneous sampling based pharmacokinetic-DFT: A highly-sensitive DFT system of CT-scanning mode working with parallel four photomultiplier-tube photon-counting channels is developed to generate an instantaneous sampling dataset; A direct reconstruction scheme then extracts images of the pharmacokinetic parameters using the adaptive-EKF strategy. We design a dynamic phantom that can simulate the agent metabolism in living tissue. The results of the dynamic phantom experiments verify the validity of the experiment system and reconstruction algorithms, and demonstrate that system provides good resolution, high sensitivity and quantitativeness at different pump speed.
Validity of the Family Asthma Management System Scale with an Urban African-American Sample
Klinnert, Mary D.; Holsey, Chanda Nicole; McQuaid, Elizabeth L.
2011-01-01
Objective To examine the reliability and validity of the Family Asthma Management System Scale for low-income African-American children with poor asthma control and caregivers under stress. The FAMSS assesses eight aspects of asthma management from a family systems perspective. Methods Forty-three children, ages 8–13, and caregivers were interviewed with the FAMSS; caregivers completed measures of primary care quality, family functioning, parenting stress, and psychological distress. Children rated their relatedness with the caregiver, and demonstrated inhaler technique. Medical records were reviewed for dates of outpatient visits for asthma. Results The FAMSS demonstrated good internal consistency. Higher scores were associated with adequate inhaler technique, recent outpatient care, less parenting stress and better family functioning. Higher scores on the Collaborative Relationship with Provider subscale were associated with greater perceived primary care quality. Conclusions The FAMSS demonstrated relevant associations with asthma management criteria and family functioning for a low-income, African-American sample. PMID:19776230
Sidor, Anna; Cierpka, Manfred
2016-01-01
A standardized assessment of a family system plays a crucial role in family therapy research and diagnostic, as well as in a family therapy itself. A 14-item short version of the General Family Questionnaire (FB-K) was designed to get a tool for assessing family functionality that is low time-consuming. The short version was developed by factor analysis from the long version FA-A. The quality criteria of the family questionnaire were verified in a control sample of 208 high-risk families four months after the birth of their child. The new family questionnaire demonstrates a very good reliability and a satisfactory 8-months-stability. The concurrent validity with the FACES scale "cohesion" is assured. Regarding the construct validity a positive correlation to the feeling of coherence was found. The family questionnaire shows a negative correlation to the maternal postnatal depressive symptoms, the degree of maternal stress burden, the dysfunctionality of the mother-child-relationship and impaired bonding. The values taken from a norm sample with infants are higher by trend and in the sample with children under 18 do not deviate from the values of the risk sample. FB-K covers two aspects of family functioning, the bond between family members and their willingness to communicate. The internal consistency of FB-K is excellent, the criterion and the construct validity are good.
INTERPRETING PHYSICAL AND BEHAVIORAL HEALTH SCORES FROM NEW WORK DISABILITY INSTRUMENTS
Marfeo, Elizabeth E.; Ni, Pengsheng; Chan, Leighton; Rasch, Elizabeth K.; McDonough, Christine M.; Brandt, Diane E.; Bogusz, Kara; Jette, Alan M.
2015-01-01
Objective To develop a system to guide interpretation of scores generated from 2 new instruments measuring work-related physical and behavioral health functioning (Work Disability – Physical Function (WD-PF) and WD – Behavioral Function (WD-BH)). Design Cross-sectional, secondary data from 3 independent samples to develop and validate the functional levels for physical and behavioral health functioning. Subjects Physical group: 999 general adult subjects, 1,017 disability applicants and 497 work-disabled subjects. Behavioral health group: 1,000 general adult subjects, 1,015 disability applicants and 476 work-disabled subjects. Methods Three-phase analytic approach including item mapping, a modified-Delphi technique, and known-groups validation analysis were used to develop and validate cut-points for functional levels within each of the WD-PF and WD-BH instrument’s scales. Results Four and 5 functional levels were developed for each of the scales in the WD-PF and WD-BH instruments. Distribution of the comparative samples was in the expected direction: the general adult samples consistently demonstrated scores at higher functional levels compared with the claimant and work-disabled samples. Conclusion Using an item-response theory-based methodology paired with a qualitative process appears to be a feasible and valid approach for translating the WD-BH and WD-PF scores into meaningful levels useful for interpreting a person’s work-related physical and behavioral health functioning. PMID:25729901
Riley, W T; McCranie, E W
1990-01-01
This study sought to compare the original and revised scoring systems of the Depressive Experiences Questionnaire (DEQ) and to assess the construct validity of the Dependent and Self-Critical subscales of the DEQ in a clinically depressed sample. Subjects were 103 depressed inpatients who completed the DEQ, the Beck Depression Inventory (BDI), the Hopelessness Scale, the Automatic Thoughts Questionnaire (ATQ), the Rathus Assertiveness Schedule (RAS), and the Minnesota Multiphasic Personality Inventory (MMPI). The original and revised scoring systems of the DEQ evidenced good concurrent validity for each factor scale, but the revised system did not sufficiently discriminate dependent and self-critical dimensions. Using the original scoring system, self-criticism was significantly and positively related to severity of depression, whereas dependency was not, particularly for males. Factor analysis of the DEQ scales and the other scales used in this study supported the dependent and self-critical dimensions. For men, the correlation of the DEQ with the MMPI scales indicated that self-criticism was associated with psychotic symptoms, hostility/conflict, and a distress/exaggerated response set, whereas dependency did not correlate significantly with any MMPI scales. Females, however, did not exhibit a differential pattern of correlations between either the Dependency or the Self-Criticism scales and the MMPI. These findings suggest possible gender differences in the clinical characteristics of male and female dependent and self-critical depressive subtypes.
Yen, Po-Yin; Sousa, Karen H; Bakken, Suzanne
2014-10-01
In a previous study, we developed the Health Information Technology Usability Evaluation Scale (Health-ITUES), which is designed to support customization at the item level. Such customization matches the specific tasks/expectations of a health IT system while retaining comparability at the construct level, and provides evidence of its factorial validity and internal consistency reliability through exploratory factor analysis. In this study, we advanced the development of Health-ITUES to examine its construct validity and predictive validity. The health IT system studied was a web-based communication system that supported nurse staffing and scheduling. Using Health-ITUES, we conducted a cross-sectional study to evaluate users' perception toward the web-based communication system after system implementation. We examined Health-ITUES's construct validity through first and second order confirmatory factor analysis (CFA), and its predictive validity via structural equation modeling (SEM). The sample comprised 541 staff nurses in two healthcare organizations. The CFA (n=165) showed that a general usability factor accounted for 78.1%, 93.4%, 51.0%, and 39.9% of the explained variance in 'Quality of Work Life', 'Perceived Usefulness', 'Perceived Ease of Use', and 'User Control', respectively. The SEM (n=541) supported the predictive validity of Health-ITUES, explaining 64% of the variance in intention for system use. The results of CFA and SEM provide additional evidence for the construct and predictive validity of Health-ITUES. The customizability of Health-ITUES has the potential to support comparisons at the construct level, while allowing variation at the item level. We also illustrate application of Health-ITUES across stages of system development. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Bertisch, Hilary; Rivara, Frederick P; Kisala, Pamela A; Wang, Jin; Yeates, Keith Owen; Durbin, Dennis; Zonfrillo, Mark R; Bell, Michael J; Temkin, Nancy; Tulsky, David S
2017-07-01
The primary objective is to provide evidence of convergent and discriminant validity for the pediatric and parent-proxy versions of the Patient-Reported Outcomes Measurement Information System (PROMIS) Anxiety, Depression, Anger, Peer Relations, Mobility, Pain Interference, and Fatigue item banks, the Neurology Quality of Life measurement system (Neuro-QOL) Cognition-General Concerns and Stigma item banks, and the Traumatic Brain Injury Quality of Life (TBI-QOL) Executive Function and Headache item banks in a pediatric traumatic brain injury (TBI) sample. Participants were 134 parent-child (ages 8-18 years) days. Children all sustained TBI and the dyads completed outcome ratings 6 months after injury at one of six medical centers across the United States. Ratings included PROMIS, Neuro-QOL, and TBI-QOL item banks, as well as the Pediatric Quality of Life inventory (PedsQL), the Health Behavior Inventory (HBI), and the Strengths and Difficulties Questionnaire (SDQ) as legacy criterion measures against which these item banks were validated. The PROMIS, Neuro-QOL, and TBI-QOL item banks demonstrated good convergent validity, as evidenced by moderate to strong correlations with comparable scales on the legacy measures. PROMIS, Neuro-QOL, and TBI-QOL item banks showed weaker correlations with ratings of unrelated constructs on legacy measures, providing evidence of discriminant validity. Our results indicate that the constructs measured by the PROMIS, Neuro-QOL, and TBI-QOL item banks are valid in our pediatric TBI sample and that it is appropriate to use these standardized scores for our primary study analyses.
Lang, Jason M; Connell, Christian M
2017-05-01
Childhood exposure to trauma, including violence and abuse, is a major public health concern that has resulted in increased efforts to promote trauma-informed child-serving systems. Trauma screening is an important component of such trauma-informed systems, yet widespread use of trauma screening is rare in part due to the lack of brief, validated trauma screening measures for children. We describe development and validation of the Child Trauma Screen (CTS), a 10-item screening measure of trauma exposure and posttraumatic stress disorder (PTSD) symptoms for children consistent with the DSM-5 definition of PTSD. Study 1 describes measure development incorporating analysis to derive items based on existing measures from 1,065 children and caregivers together with stakeholder input to finalize item selection. Study 2 describes validation of the CTS with a clinical sample of 74 children and their caregivers. Results support the CTS as an empirically derived, reliable measure to screen children for trauma exposure and PTSD symptoms with strong convergent, divergent, and criterion validity. The CTS is a promising measure for rapidly and reliably screening children for trauma exposure and PTSD symptoms. Future research is needed to confirm validation and to examine feasibility and utility of its use across various child-serving systems. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Mottier, Nicolas; Tharin, Manuel; Cluse, Camille; Crudo, Jean-René; Lueso, María Gómez; Goujon-Ginglinger, Catherine G; Jaquier, Anne; Mitova, Maya I; Rouget, Emmanuel G R; Schaller, Mathieu; Solioz, Jennifer
2016-09-01
Studies in environmentally controlled rooms have been used over the years to assess the impact of environmental tobacco smoke on indoor air quality. As new tobacco products are developed, it is important to determine their impact on air quality when used indoors. Before such an assessment can take place it is essential that the analytical methods used to assess indoor air quality are validated and shown to be fit for their intended purpose. Consequently, for this assessment, an environmentally controlled room was built and seven analytical methods, representing eighteen analytes, were validated. The validations were carried out with smoking machines using a matrix-based approach applying the accuracy profile procedure. The performances of the methods were compared for all three matrices under investigation: background air samples, the environmental aerosol of Tobacco Heating System THS 2.2, a heat-not-burn tobacco product developed by Philip Morris International, and the environmental tobacco smoke of a cigarette. The environmental aerosol generated by the THS 2.2 device did not have any appreciable impact on the performances of the methods. The comparison between the background and THS 2.2 environmental aerosol samples generated by smoking machines showed that only five compounds were higher when THS 2.2 was used in the environmentally controlled room. Regarding environmental tobacco smoke from cigarettes, the yields of all analytes were clearly above those obtained with the other two air sample types. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Model Transformation for a System of Systems Dependability Safety Case
NASA Technical Reports Server (NTRS)
Murphy, Judy; Driskell, Steve
2011-01-01
The presentation reviews the dependability and safety effort of NASA's Independent Verification and Validation Facility. Topics include: safety engineering process, applications to non-space environment, Phase I overview, process creation, sample SRM artifact, Phase I end result, Phase II model transformation, fault management, and applying Phase II to individual projects.
WetLab-2: Wet Lab RNA SmartCycler Providing PCR Capability on ISS
NASA Technical Reports Server (NTRS)
Parra, Macarena; Schonfeld, Julie
2015-01-01
The WetLab-2 system will provide sample preparation and qRT-PCR analysis on-board the ISS, a capability to enable using the ISS as a real laboratory. The system will be validated on SpX-7, and is planned for its first PI use on SpX-9.
Lin, Wen-Ye; Chang, Jung-Tzu; Chu, Chun-Feng
2017-01-01
Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3–5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future. PMID:28683148
Lin, Shu-Ping; Lin, Wen-Ye; Chang, Jung-Tzu; Chu, Chun-Feng
2017-01-01
Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3-5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future.
Ghosal, Sayan; Gannepalli, Anil; Salapaka, Murti
2017-08-11
In this article, we explore methods that enable estimation of material properties with the dynamic mode atomic force microscopy suitable for soft matter investigation. The article presents the viewpoint of casting the system, comprising of a flexure probe interacting with the sample, as an equivalent cantilever system and compares a steady-state analysis based method with a recursive estimation technique for determining the parameters of the equivalent cantilever system in real time. The steady-state analysis of the equivalent cantilever model, which has been implicitly assumed in studies on material property determination, is validated analytically and experimentally. We show that the steady-state based technique yields results that quantitatively agree with the recursive method in the domain of its validity. The steady-state technique is considerably simpler to implement, however, slower compared to the recursive technique. The parameters of the equivalent system are utilized to interpret storage and dissipative properties of the sample. Finally, the article identifies key pitfalls that need to be avoided toward the quantitative estimation of material properties.
TOEFL iBT Speaking Test Scores as Indicators of Oral Communicative Language Proficiency
ERIC Educational Resources Information Center
Bridgeman, Brent; Powers, Donald; Stone, Elizabeth; Mollaun, Pamela
2012-01-01
Scores assigned by trained raters and by an automated scoring system (SpeechRater[TM]) on the speaking section of the TOEFL iBT[TM] were validated against a communicative competence criterion. Specifically, a sample of 555 undergraduate students listened to speech samples from 184 examinees who took the Test of English as a Foreign Language…
Validity of a computerized population registry of dementia based on clinical databases.
Mar, J; Arrospide, A; Soto-Gordoa, M; Machón, M; Iruin, Á; Martinez-Lage, P; Gabilondo, A; Moreno-Izco, F; Gabilondo, A; Arriola, L
2018-05-08
The handling of information through digital media allows innovative approaches for identifying cases of dementia through computerized searches within the clinical databases that include systems for coding diagnoses. The aim of this study was to analyze the validity of a dementia registry in Gipuzkoa based on the administrative and clinical databases existing in the Basque Health Service. This is a descriptive study based on the evaluation of available data sources. First, through review of medical records, the diagnostic validity was evaluated in 2 samples of cases identified and not identified as dementia. The sensitivity, specificity and positive and negative predictive value of the diagnosis of dementia were measured. Subsequently, the cases of living dementia in December 31, 2016 were searched in the entire Gipuzkoa population to collect sociodemographic and clinical variables. The validation samples included 986 cases and 327 no cases. The calculated sensitivity was 80.2% and the specificity was 99.9%. The negative predictive value was 99.4% and positive value was 95.1%. The cases in Gipuzkoa were 10,551, representing 65% of the cases predicted according to the literature. Antipsychotic medication were taken by a 40% and a 25% of the cases were institutionalized. A registry of dementias based on clinical and administrative databases is valid and feasible. Its main contribution is to show the dimension of dementia in the health system. Copyright © 2018 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.
NASA Technical Reports Server (NTRS)
Kubat, Gregory
2016-01-01
This report provides a description and performance characterization of the large-scale, Relay architecture, UAS communications simulation capability developed for the NASA GRC, UAS in the NAS Project. The system uses a validated model of the GRC Gen5 CNPC, Flight-Test Radio model. Contained in the report is a description of the simulation system and its model components, recent changes made to the system to improve performance, descriptions and objectives of sample simulations used for test and verification, and a sampling and observations of results and performance data.
Zou, Lili; Shen, Kaini; Zhong, Dingrong; Zhou, Daobin; Sun, Wei; Li, Jian
2015-01-01
Laser microdissection followed by mass spectrometry has been successfully used for amyloid typing. However, sample contamination can interfere with proteomic analysis, and overnight digestion limits the analytical throughput. Moreover, current quantitative analysis methods are based on the spectrum count, which ignores differences in protein length and may lead to misdiagnoses. Here, we developed a microwave-assisted filter-aided sample preparation (maFASP) method that can efficiently remove contaminants with a 10-kDa cutoff ultrafiltration unit and can accelerate the digestion process with the assistance of a microwave. Additionally, two parameters (P- and D-scores) based on the exponentially modified protein abundance index were developed to define the existence of amyloid deposits and those causative proteins with the greatest abundance. Using our protocol, twenty cases of systemic amyloidosis that were well-typed according to clinical diagnostic standards (training group) and another twenty-four cases without subtype diagnoses (validation group) were analyzed. Using this approach, sample preparation could be completed within four hours. We successfully subtyped 100% of the cases in the training group, and the diagnostic success rate in the validation group was 91.7%. This maFASP-aided proteomic protocol represents an efficient approach for amyloid diagnosis and subtyping, particularly for serum-contaminated samples. PMID:25984759
The Adult Attachment Projective Picture System: integrating attachment into clinical assessment.
George, Carol; West, Malcolm
2011-01-01
This article summarizes the development and validation of the Adult Attachment Projective System (AAP), a measure we developed from the Bowlby-Ainsworth developmental tradition to assess adult attachment status. The AAP has demonstrated excellent concurrent validity with the Adult Attachment Interview (George, Kaplan, & Main, 1984/1985/1996; Main & Goldwyn, 1985-1994; Main, Goldwyn, & Hesse, 2003), interjudge reliability, and test-retest reliability, with no effects of verbal intelligence or social desirability. The AAP coding and classification system and application in clinical and community samples are summarized. Finally, we introduce the 3 other articles that are part of this Special Section and discuss the use of the AAP in therapeutic assessment and treatment.
Hayashi-Takagi, Akiko; Vawter, Marquis P; Iwamoto, Kazuya
2014-06-15
Peripheral samples, such as blood and skin, have been used for decades in psychiatric research as surrogates for central nervous system samples. Although the validity of the data obtained from peripheral samples has been questioned and other state-of-the-art techniques, such as human brain imaging, genomics, and induced pluripotent stem cells, seem to reduce the value of peripheral cells, accumulating evidence has suggested that revisiting peripheral samples is worthwhile. Here, we re-evaluate the utility of peripheral samples and argue that establishing an understanding of the common signaling and biological processes in the brain and peripheral samples is required for the validity of such models. First, we present an overview of the available types of peripheral cells and describe their advantages and disadvantages. We then briefly summarize the main achievements of omics studies, including epigenome, transcriptome, proteome, and metabolome analyses, as well as the main findings of functional cellular assays, the results of which imply that alterations in neurotransmission, metabolism, the cell cycle, and the immune system may be partially responsible for the pathophysiology of major psychiatric disorders such as schizophrenia. Finally, we discuss the future utility of peripheral samples for the development of biomarkers and tailor-made therapies, such as multimodal assays that are used as a battery of disease and trait pathways and that might be potent and complimentary tools for use in psychiatric research. © 2013 Society of Biological Psychiatry Published by Society of Biological Psychiatry All rights reserved.
Nelson, Jennifer Clark; Marsh, Tracey; Lumley, Thomas; Larson, Eric B; Jackson, Lisa A; Jackson, Michael L
2013-08-01
Estimates of treatment effectiveness in epidemiologic studies using large observational health care databases may be biased owing to inaccurate or incomplete information on important confounders. Study methods that collect and incorporate more comprehensive confounder data on a validation cohort may reduce confounding bias. We applied two such methods, namely imputation and reweighting, to Group Health administrative data (full sample) supplemented by more detailed confounder data from the Adult Changes in Thought study (validation sample). We used influenza vaccination effectiveness (with an unexposed comparator group) as an example and evaluated each method's ability to reduce bias using the control time period before influenza circulation. Both methods reduced, but did not completely eliminate, the bias compared with traditional effectiveness estimates that do not use the validation sample confounders. Although these results support the use of validation sampling methods to improve the accuracy of comparative effectiveness findings from health care database studies, they also illustrate that the success of such methods depends on many factors, including the ability to measure important confounders in a representative and large enough validation sample, the comparability of the full sample and validation sample, and the accuracy with which the data can be imputed or reweighted using the additional validation sample information. Copyright © 2013 Elsevier Inc. All rights reserved.
Nelson, Jennifer C.; Marsh, Tracey; Lumley, Thomas; Larson, Eric B.; Jackson, Lisa A.; Jackson, Michael
2014-01-01
Objective Estimates of treatment effectiveness in epidemiologic studies using large observational health care databases may be biased due to inaccurate or incomplete information on important confounders. Study methods that collect and incorporate more comprehensive confounder data on a validation cohort may reduce confounding bias. Study Design and Setting We applied two such methods, imputation and reweighting, to Group Health administrative data (full sample) supplemented by more detailed confounder data from the Adult Changes in Thought study (validation sample). We used influenza vaccination effectiveness (with an unexposed comparator group) as an example and evaluated each method’s ability to reduce bias using the control time period prior to influenza circulation. Results Both methods reduced, but did not completely eliminate, the bias compared with traditional effectiveness estimates that do not utilize the validation sample confounders. Conclusion Although these results support the use of validation sampling methods to improve the accuracy of comparative effectiveness findings from healthcare database studies, they also illustrate that the success of such methods depends on many factors, including the ability to measure important confounders in a representative and large enough validation sample, the comparability of the full sample and validation sample, and the accuracy with which data can be imputed or reweighted using the additional validation sample information. PMID:23849144
Creating and validating GIS measures of urban design for health research.
Purciel, Marnie; Neckerman, Kathryn M; Lovasi, Gina S; Quinn, James W; Weiss, Christopher; Bader, Michael D M; Ewing, Reid; Rundle, Andrew
2009-12-01
Studies relating urban design to health have been impeded by the unfeasibility of conducting field observations across large areas and the lack of validated objective measures of urban design. This study describes measures for five dimensions of urban design - imageability, enclosure, human scale, transparency, and complexity - created using public geographic information systems (GIS) data from the US Census and city and state government. GIS measures were validated for a sample of 588 New York City block faces using a well-documented field observation protocol. Correlations between GIS and observed measures ranged from 0.28 to 0.89. Results show valid urban design measures can be constructed from digital sources.
Creating and validating GIS measures of urban design for health research
Purciel, Marnie; Neckerman, Kathryn M.; Lovasi, Gina S.; Quinn, James W.; Weiss, Christopher; Bader, Michael D.M.; Ewing, Reid; Rundle, Andrew
2012-01-01
Studies relating urban design to health have been impeded by the unfeasibility of conducting field observations across large areas and the lack of validated objective measures of urban design. This study describes measures for five dimensions of urban design – imageability, enclosure, human scale, transparency, and complexity – created using public geographic information systems (GIS) data from the US Census and city and state government. GIS measures were validated for a sample of 588 New York City block faces using a well-documented field observation protocol. Correlations between GIS and observed measures ranged from 0.28 to 0.89. Results show valid urban design measures can be constructed from digital sources. PMID:22956856
NASA Astrophysics Data System (ADS)
Lu, Zenghai; Kasaragod, Deepa K.; Matcher, Stephen J.
2012-03-01
We demonstrate theoretically and experimentally that the phase retardance and relative optic-axis orientation of a sample can be calculated without prior knowledge of the actual value of the phase modulation amplitude when using a polarization-sensitive optical coherence tomography system based on continuous polarization modulation (CPM-PS-OCT). We also demonstrate that the sample Jones matrix can be calculated at any values of the phase modulation amplitude in a reasonable range depending on the system effective signal-to-noise ratio. This has fundamental importance for the development of clinical systems by simplifying the polarization modulator drive instrumentation and eliminating its calibration procedure. This was validated on measurements of a three-quarter waveplate and an equine tendon sample by a fiber-based swept-source CPM-PS-OCT system.
NASA Astrophysics Data System (ADS)
Ivanova, B. B.; Simeonov, V. D.; Arnaudov, M. G.; Tsalev, D. L.
2007-05-01
A validation of the developed new orientation method of solid samples as suspension in nematic liquid crystal (NLC), applied in linear-dichroic infrared (IR-LD) spectroscopy has been carried out using a model system DL-isoleucine ( DL-isoleu). Accuracy, precision and the influence of the liquid crystal medium on peak positions and integral absorbances of guest molecules have been presented. Optimization of experimental conditions has been performed as well. An experimental design for quantitative evaluation of the impact of four input factors: the number of scans, the rubbing-out of KBr-pellets, the amount of studied compounds included in the liquid crystal medium and the ratios of Lorentzian to Gaussian peak functions in the curve fitting procedure on the spectroscopic signal at five different frequencies, indicating important specifities of the system has been studied.
López, Diego M; Blobel, Bernd; Gonzalez, Carolina
2010-01-01
Requirement analysis, design, implementation, evaluation, use, and maintenance of semantically interoperable Health Information Systems (HIS) have to be based on eHealth standards. HIS-DF is a comprehensive approach for HIS architectural development based on standard information models and vocabulary. The empirical validity of HIS-DF has not been demonstrated so far. Through an empirical experiment, the paper demonstrates that using HIS-DF and HL7 information models, semantic quality of HIS architecture can be improved, compared to architectures developed using traditional RUP process. Semantic quality of the architecture has been measured in terms of model's completeness and validity metrics. The experimental results demonstrated an increased completeness of 14.38% and an increased validity of 16.63% when using the HIS-DF and HL7 information models in a sample HIS development project. Quality assurance of the system architecture in earlier stages of HIS development presumes an increased quality of final HIS systems, which supposes an indirect impact on patient care.
Validity of a portable glucose, total cholesterol, and triglycerides multi-analyzer in adults.
Coqueiro, Raildo da Silva; Santos, Mateus Carmo; Neto, João de Souza Leal; Queiroz, Bruno Morbeck de; Brügger, Nelson Augusto Jardim; Barbosa, Aline Rodrigues
2014-07-01
This study investigated the accuracy and precision of the Accutrend Plus system to determine blood glucose, total cholesterol, and plasma triglycerides in adults and evaluated its efficiency in measuring these blood variables. The sample consisted of 53 subjects (≥ 18 years). For blood variable laboratory determination, venous blood samples were collected and processed in a Labmax 240 analyzer. To measure blood variables with the Accutrend Plus system, samples of capillary blood were collected. In the analysis, the following tests were included: Wilcoxon and Student's t-tests for paired samples, Lin's concordance coefficient, Bland-Altman method, receiver operating characteristic curve, McNemar test, and k statistics. The results show that the Accutrend Plus system provided significantly higher values (p ≤ .05) of glucose and triglycerides but not of total cholesterol (p > .05) as compared to the values determined in the laboratory. However, the system showed good reproducibility (Lin's coefficient: glucose = .958, triglycerides = .992, total cholesterol = .940) and high concordance with the laboratory method (Lin's coefficient: glucose = .952, triglycerides = .990, total cholesterol = .944) and high sensitivity (glucose = 80.0%, triglycerides = 90.5%, total cholesterol = 84.4%) and specificity (glucose = 100.0%, triglycerides = 96.9%, total cholesterol = 95.2%) in the discrimination of high values of the three blood variables analyzed. It could be concluded that despite the tendency to overestimate glucose and triglyceride levels, a portable multi-analyzer is a valid alternative for the monitoring of metabolic disorders and cardiovascular risk factors. © The Author(s) 2013.
Evaluation of a 13-loci STR multiplex system for Cannabis sativa genetic identification.
Houston, Rachel; Birck, Matthew; Hughes-Stamm, Sheree; Gangitano, David
2016-05-01
Marijuana (Cannabis sativa) is the most commonly used illicit substance in the USA. The development of a validated method using Cannabis short tandem repeats (STRs) could aid in the individualization of samples as well as serve as an intelligence tool to link multiple cases. For this purpose, a modified 13-loci STR multiplex method was optimized and evaluated according to ISFG and SWGDAM guidelines. A real-time PCR quantification method for C. sativa was developed and validated, and a sequenced allelic ladder was also designed to accurately genotype 199 C. sativa samples from 11 U.S. Customs and Border Protection seizures. Distinguishable DNA profiles were generated from 127 samples that yielded full STR profiles. Four duplicate genotypes within seizures were found. The combined power of discrimination of this multilocus system is 1 in 70 million. The sensitivity of the multiplex STR system is 0.25 ng of template DNA. None of the 13 STR markers cross-reacted with any of the studied species, except for Humulus lupulus (hops) which generated unspecific peaks. Phylogenetic analysis and case-to-case pairwise comparison of 11 cases using F st as genetic distance revealed the genetic association of four groups of cases. Moreover, due to their genetic similarity, a subset of samples (N = 97) was found to form a homogeneous population in Hardy-Weinberg and linkage equilibrium. The results of this research demonstrate the applicability of this 13-loci STR system in associating Cannabis cases for intelligence purposes.
Shenker, Bennett S
2014-02-01
To validate a scoring system that evaluates the ability of Internet search engines to correctly predict diagnoses when symptoms are used as search terms. We developed a five point scoring system to evaluate the diagnostic accuracy of Internet search engines. We identified twenty diagnoses common to a primary care setting to validate the scoring system. One investigator entered the symptoms for each diagnosis into three Internet search engines (Google, Bing, and Ask) and saved the first five webpages from each search. Other investigators reviewed the webpages and assigned a diagnostic accuracy score. They rescored a random sample of webpages two weeks later. To validate the five point scoring system, we calculated convergent validity and test-retest reliability using Kendall's W and Spearman's rho, respectively. We used the Kruskal-Wallis test to look for differences in accuracy scores for the three Internet search engines. A total of 600 webpages were reviewed. Kendall's W for the raters was 0.71 (p<0.0001). Spearman's rho for test-retest reliability was 0.72 (p<0.0001). There was no difference in scores based on Internet search engine. We found a significant difference in scores based on the webpage's order on the Internet search engine webpage (p=0.007). Pairwise comparisons revealed higher scores in the first webpages vs. the fourth (corr p=0.009) and fifth (corr p=0.017). However, this significance was lost when creating composite scores. The five point scoring system to assess diagnostic accuracy of Internet search engines is a valid and reliable instrument. The scoring system may be used in future Internet research. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jonsson, Jacob C.; Branden, Henrik
2006-10-19
This paper demonstrates a method to determine thebidirectional transfer distribution function (BTDF) using an integratingsphere. Information about the sample's angle dependent scattering isobtained by making transmittance measurements with the sample atdifferent distances from the integrating sphere. Knowledge about theilluminated area of the sample and the geometry of the sphere port incombination with the measured data combines to an system of equationsthat includes the angle dependent transmittance. The resulting system ofequations is an ill-posed problem which rarely gives a physical solution.A solvable system is obtained by using Tikhonov regularization on theill-posed problem. The solution to this system can then be usedmore » to obtainthe BTDF. Four bulk-scattering samples were characterised using both twogoniophotometers and the described method to verify the validity of thenew method. The agreement shown is great for the more diffuse samples.The solution to the low-scattering samples contains unphysicaloscillations, butstill gives the correct shape of the solution. Theorigin of the oscillations and why they are more prominent inlow-scattering samples are discussed.« less
Dubreil, Estelle; Gautier, Sophie; Fourmond, Marie-Pierre; Bessiral, Mélaine; Gaugain, Murielle; Verdon, Eric; Pessel, Dominique
2017-04-01
An approach is described to validate a fast and simple targeted screening method for antibiotic analysis in meat and aquaculture products by LC-MS/MS. The strategy of validation was applied for a panel of 75 antibiotics belonging to different families, i.e., penicillins, cephalosporins, sulfonamides, macrolides, quinolones and phenicols. The samples were extracted once with acetonitrile, concentrated by evaporation and injected into the LC-MS/MS system. The approach chosen for the validation was based on the Community Reference Laboratory (CRL) guidelines for the validation of screening qualitative methods. The aim of the validation was to prove sufficient sensitivity of the method to detect all the targeted antibiotics at the level of interest, generally the maximum residue limit (MRL). A robustness study was also performed to test the influence of different factors. The validation showed that the method is valid to detect and identify 73 antibiotics of the 75 antibiotics studied in meat and aquaculture products at the validation levels.
Assink, Mark; van der Put, Claudia E; Oort, Frans J; Stams, Geert Jan J M
2015-03-04
In The Netherlands, police officers not only come into contact with juvenile offenders, but also with a large number of juveniles who were involved in a criminal offense, but not in the role of a suspect (i.e., juvenile non-offenders). Until now, no valid and reliable instrument was available that can be used by Dutch police officers for estimating the risk for future care needs of juvenile non-offenders. In the present study, the Youth Actuarial Care Needs Assessment Tool for Non-Offenders (Y-ACNAT-NO) was developed for predicting the risk for future care needs that consisted of (1) a future supervision order as imposed by a juvenile court judge and (2) future worrisome incidents involving child abuse, domestic violence/strife, and/or sexual offensive behavior at the juvenile's living address (i.e., problems in the child-rearing environment). Police records of 3,200 juveniles were retrieved from the Dutch police registration system after which the sample was randomly split in a construction (n = 1,549) and validation sample (n = 1,651). The Y-ACNAT-NO was developed by performing an Exhaustive CHAID analysis using the construction sample. The predictive validity of the instrument was examined in the validation sample by calculating several performance indicators that assess discrimination and calibration. The CHAID output yielded an instrument that consisted of six variables and eleven different risk groups. The risk for future care needs ranged from 0.06 in the lowest risk group to 0.83 in the highest risk group. The AUC value in the validation sample was .764 (95% CI [.743, .784]) and Sander's calibration score indicated an average assessment error of 3.74% in risk estimates per risk category. The Y-ACNAT-NO is the first instrument that can be used by Dutch police officers for estimating the risk for future care needs of juvenile non-offenders. The predictive validity of the Y-ACNAT-NO in terms of discrimination and calibration was sufficient to justify its use as an initial screening instrument when a decision is needed about referring a juvenile for further assessment of care needs.
Walsh, Susan; Chaitanya, Lakshmi; Clarisse, Lindy; Wirken, Laura; Draus-Barini, Jolanta; Kovatsi, Leda; Maeda, Hitoshi; Ishikawa, Takaki; Sijen, Titia; de Knijff, Peter; Branicki, Wojciech; Liu, Fan; Kayser, Manfred
2014-03-01
Forensic DNA Phenotyping or 'DNA intelligence' tools are expected to aid police investigations and find unknown individuals by providing information on externally visible characteristics of unknown suspects, perpetrators and missing persons from biological samples. This is especially useful in cases where conventional DNA profiling or other means remain non-informative. Recently, we introduced the HIrisPlex system, capable of predicting both eye and hair colour from DNA. In the present developmental validation study, we demonstrate that the HIrisPlex assay performs in full agreement with the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines providing an essential prerequisite for future HIrisPlex applications to forensic casework. The HIrisPlex assay produces complete profiles down to only 63 pg of DNA. Species testing revealed human specificity for a complete HIrisPlex profile, while only non-human primates showed the closest full profile at 20 out of the 24 DNA markers, in all animals tested. Rigorous testing of simulated forensic casework samples such as blood, semen, saliva stains, hairs with roots as well as extremely low quantity touch (trace) DNA samples, produced complete profiles in 88% of cases. Concordance testing performed between five independent forensic laboratories displayed consistent reproducible results on varying types of DNA samples. Due to its design, the assay caters for degraded samples, underlined here by results from artificially degraded DNA and from simulated casework samples of degraded DNA. This aspect was also demonstrated previously on DNA samples from human remains up to several hundreds of years old. With this paper, we also introduce enhanced eye and hair colour prediction models based on enlarged underlying databases of HIrisPlex genotypes and eye/hair colour phenotypes (eye colour: N = 9188 and hair colour: N = 1601). Furthermore, we present an online web-based system for individual eye and hair colour prediction from full and partial HIrisPlex DNA profiles. By demonstrating that the HIrisPlex assay is fully compatible with the SWGDAM guidelines, we provide the first forensically validated DNA test system for parallel eye and hair colour prediction now available to forensic laboratories for immediate casework application, including missing person cases. Given the robustness and sensitivity described here and in previous work, the HIrisPlex system is also suitable for analysing old and ancient DNA in anthropological and evolutionary studies. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Zhang, Ti; Cai, Shuang; Forrest, Wai Chee; Mohr, Eva; Yang, Qiuhong; Forrest, M Laird
2016-09-01
Cisplatin, a platinum chemotherapeutic, is one of the most commonly used chemotherapeutic agents for many solid tumors. In this work, we developed and validated an inductively coupled plasma mass spectrometry (ICP-MS) method for quantitative determination of platinum levels in rat urine, plasma, and tissue matrices including liver, brain, lungs, kidney, muscle, heart, spleen, bladder, and lymph nodes. The tissues were processed using a microwave accelerated reaction system (MARS) system prior to analysis on an Agilent 7500 ICP-MS. According to the Food and Drug Administration guidance for industry, bioanalytical validation parameters of the method, such as selectivity, accuracy, precision, recovery, and stability were evaluated in rat biological samples. Our data suggested that the method was selective for platinum without interferences caused by other presenting elements, and the lower limit of quantification was 0.5 ppb. The accuracy and precision of the method were within 15% variation and the recoveries of platinum for all tissue matrices examined were determined to be 85-115% of the theoretical values. The stability of the platinum-containing solutions, including calibration standards, stock solutions, and processed samples in rat biological matrices was investigated. Results indicated that the samples were stable after three cycles of freeze-thaw and for up to three months. © The Author(s) 2016.
Zhang, Ti; Cai, Shuang; Forrest, Wai Chee; Mohr, Eva; Yang, Qiuhong; Forrest, M. Laird
2016-01-01
Cisplatin, a platinum chemotherapeutic, is one of the most commonly used chemotherapeutic agents for many solid tumors. In this work, we developed and validated an inductively coupled plasma mass spectrometry (ICP-MS) method for quantitative determination of platinum levels in rat urine, plasma, and tissue matrices including liver, brain, lungs, kidney, muscle, heart, spleen, bladder, and lymph nodes. The tissues were processed using a microwave accelerated reaction system (MARS) system prior to analysis on an Agilent 7500 ICP-MS. According to the Food and Drug Administration guidance for industry, bioanalytical validation parameters of the method, such as selectivity, accuracy, precision, recovery, and stability were evaluated in rat biological samples. Our data suggested that the method was selective for platinum without interferences caused by other presenting elements, and the lower limit of quantification was 0.5 ppb. The accuracy and precision of the method were within 15% variation and the recoveries of platinum for all tissue matrices examined were determined to be 85–115% of the theoretical values. The stability of the platinum-containing solutions, including calibration standards, stock solutions, and processed samples in rat biological matrices was investigated. Results indicated that the samples were stable after three cycles of freeze–thaw and for up to three months. PMID:27527103
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santamaria, L.; Siller, H. R.; Garcia-Ortiz, C. E., E-mail: cegarcia@cicese.mx
In this work, we present an alternative optical method to determine the probe-sample separation distance in a scanning near-field optical microscope. The experimental method is based in a Lloyd’s mirror interferometer and offers a measurement precision deviation of ∼100 nm using digital image processing and numerical analysis. The technique can also be strategically combined with the characterization of piezoelectric actuators and stability evaluation of the optical system. It also opens the possibility for the development of an automatic approximation control system valid for probe-sample distances from 5 to 500 μm.
Souza, C A; Oliveira, T C; Crovella, S; Santos, S M; Rabêlo, K C N; Soriano, E P; Carvalho, M V D; Junior, A F Caldas; Porto, G G; Campello, R I C; Antunes, A A; Queiroz, R A; Souza, S M
2017-04-28
The use of Y chromosome haplotypes, important for the detection of sexual crimes in forensics, has gained prominence with the use of databases that incorporate these genetic profiles in their system. Here, we optimized and validated an amplification protocol for Y chromosome profile retrieval in reference samples using lesser materials than those in commercial kits. FTA ® cards (Flinders Technology Associates) were used to support the oral cells of male individuals, which were amplified directly using the SwabSolution reagent (Promega). First, we optimized and validated the process to define the volume and cycling conditions. Three reference samples and nineteen 1.2 mm-diameter perforated discs were used per sample. Amplification of one or two discs (samples) with the PowerPlex ® Y23 kit (Promega) was performed using 25, 26, and 27 thermal cycles. Twenty percent, 32%, and 100% reagent volumes, one disc, and 26 cycles were used for the control per sample. Thereafter, all samples (N = 270) were amplified using 27 cycles, one disc, and 32% reagents (optimized conditions). Data was analyzed using a study of equilibrium values between fluorophore colors. In the samples analyzed with 20% volume, an imbalance was observed in peak heights, both inside and in-between each dye. In samples amplified with 32% reagents, the values obtained for the intra-color and inter-color standard balance calculations for verification of the quality of the analyzed peaks were similar to those of samples amplified with 100% of the recommended volume. The quality of the profiles obtained with 32% reagents was suitable for insertion into databases.
Corr, Philip J; Cooper, Andrew J
2016-11-01
We report the development and validation of a questionnaire measure of the revised reinforcement sensitivity theory (rRST) of personality. Starting with qualitative responses to defensive and approach scenarios modeled on typical rodent ethoexperimental situations, exploratory and confirmatory factor analyses (CFAs) revealed a robust 6-factor structure: 2 unitary defensive factors, fight-flight-freeze system (FFFS; related to fear) and the behavioral inhibition system (BIS; related to anxiety); and 4 behavioral approach system (BAS) factors (Reward Interest, Goal-Drive Persistence, Reward Reactivity, and Impulsivity). Theoretically motivated thematic facets were employed to sample the breadth of defensive space, comprising FFFS (Flight, Freeze, and Active Avoidance) and BIS (Motor Planning Interruption, Worry, Obsessive Thoughts, and Behavioral Disengagement). Based on theoretical considerations, and statistically confirmed, a separate scale for Defensive Fight was developed. Validation evidence for the 6-factor structure came from convergent and discriminant validity shown by correlations with existing personality scales. We offer the Reinforcement Sensitivity Theory of Personality Questionnaire to facilitate future research specifically on rRST and, more broadly, on approach-avoidance theories of personality. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Setel, Philip W.; Sankoh, Osman; Rao, Chalapati; Velkoff, Victoria A.; Mathers, Colin; Gonghuan, Yang; Hemed, Yusuf; Jha, Prabhat; Lopez, Alan D.
2005-01-01
Registration of births, recording deaths by age, sex and cause, and calculating mortality levels and differentials are fundamental to evidence-based health policy, monitoring and evaluation. Yet few of the countries with the greatest need for these data have functioning systems to produce them despite legislation providing for the establishment and maintenance of vital registration. Sample vital registration (SVR), when applied in conjunction with validated verbal autopsy procedures and implemented in a nationally representative sample of population clusters represents an affordable, cost-effective, and sustainable short- and medium-term solution to this problem. SVR complements other information sources by producing age-, sex-, and cause-specific mortality data that are more complete and continuous than those currently available. The tools and methods employed in an SVR system, however, are imperfect and require rigorous validation and continuous quality assurance; sampling strategies for SVR are also still evolving. Nonetheless, interest in establishing SVR is rapidly growing in Africa and Asia. Better systems for reporting and recording data on vital events will be sustainable only if developed hand-in-hand with existing health information strategies at the national and district levels; governance structures; and agendas for social research and development monitoring. If the global community wishes to have mortality measurements 5 or 10 years hence, the foundation stones of SVR must be laid today. PMID:16184280
Jank, Louise; Martins, Magda Targa; Arsand, Juliana Bazzan; Hoff, Rodrigo Barcellos; Barreto, Fabiano; Pizzolato, Tânia Mara
2015-01-01
This study describes the development and validation procedures for scope extension of a method for the determination of β-lactam antibiotic residues (ampicillin, amoxicillin, penicillin G, penicillin V, oxacillin, cloxacillin, dicloxacillin, nafcillin, ceftiofur, cefquinome, cefoperazone, cephapirine, cefalexin and cephalonium) in bovine milk. Sample preparation was performed by liquid-liquid extraction (LLE) followed by two clean-up steps, including low temperature purification (LTP) and a solid phase dispersion clean-up. Extracts were analysed using a liquid chromatography-electrospray-tandem mass spectrometry system (LC-ESI-MS/MS). Chromatographic separation was performed in a C18 column, using methanol and water (both with 0.1% of formic acid) as mobile phase. Method validation was performed according to the criteria of Commission Decision 2002/657/EC. Main validation parameters such as linearity, limit of detection, decision limit (CCα), detection capability (CCβ), accuracy, and repeatability were determined and were shown to be adequate. The method was applied to real samples (more than 250) and two milk samples had levels above maximum residues limits (MRLs) for cloxacillin - CLX and cefapirin - CFAP.
Beltrán, Eduardo; Ibáñez, María; Sancho, Juan Vicente; Hernández, Félix
2009-06-01
A rapid multianalyte-multiclass method with little sample manipulation has been developed for the simultaneous determination of eleven mycotoxins in different food commodities by using ultra-high-pressure liquid chromatography coupled to triple quadrupole mass spectrometry (UHPLC/MS/MS). Toxins were extracted from the samples with acetonitrile/water (80:20, v/v) 0.1% HCOOH and, after a two-fold dilution with water, directly injected into the system. Thanks to the fast high-resolution separation of UHPLC, the eleven mycotoxins were separated by gradient elution in only 4 min. The method has been validated in three food matrices (maize kernels, dry pasta (wheat), and eight-multicereal babyfood (wheat, maize, rice, oat, barley, rye, sorghum, millet)) at four different concentration levels. Satisfactory recoveries were obtained (70-110%) and precision (expressed as relative standard deviation) was typically below 15% with very few exceptions. Quantification of samples was carried out with matrix-matched standards calibration. The lowest concentration successfully validated in sample was as low as 0.5 microg/kg for aflatoxins and ochratoxin A in babyfood, and 20 microg/kg for the rest of the selected mycotoxins in all matrices tested. Deoxynivalenol could be only validated at 200 microg/kg, due the poor sensitivity for this mycotoxin analysis. With only two exceptions (HT-2 and deoxynivalenol), the limits of detection (LODs), estimated for a signal-to-noise ratio of 3 from the chromatograms of samples spiked at the lowest level validated, varied between 0.1 and 1 microg/kg in the three food matrices tested. The method was applied to the analysis of different kinds of samples. Positive findings were confirmed by acquiring two transitions (Q quantification, q confirmation) and evaluating the Q/q ratio. Copyright (c) 2009 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Meng, Su; Chen, Jie; Sun, Jian
2017-10-01
This paper investigates the problem of observer-based output feedback control for networked control systems with non-uniform sampling and time-varying transmission delay. The sampling intervals are assumed to vary within a given interval. The transmission delay belongs to a known interval. A discrete-time model is first established, which contains time-varying delay and norm-bounded uncertainties coming from non-uniform sampling intervals. It is then converted to an interconnection of two subsystems in which the forward channel is delay-free. The scaled small gain theorem is used to derive the stability condition for the closed-loop system. Moreover, the observer-based output feedback controller design method is proposed by utilising a modified cone complementary linearisation algorithm. Finally, numerical examples illustrate the validity and superiority of the proposed method.
Optical-fiber-based Mueller optical coherence tomography.
Jiao, Shuliang; Yu, Wurong; Stoica, George; Wang, Lihong V
2003-07-15
An optical-fiber-based multichannel polarization-sensitive Mueller optical coherence tomography (OCT) system was built to acquire the Jones or Mueller matrix of a scattering medium, such as biological tissue. For the first time to our knowledge, fiber-based polarization-sensitive OCT was dynamically calibrated to eliminate the polarization distortion caused by the single-mode optical fiber in the sample arm, thereby overcoming a key technical impediment to the application of optical fibers in this technology. The round-trip Jones matrix of the sampling fiber was acquired from the reflecting surface of the sample for each depth scan (A scan) with our OCT system. A new rigorous algorithm was then used to retrieve the calibrated polarization properties of the sample. This algorithm was validated with experimental data. The skin of a rat was imaged with this fiber-based system.
Validation of the REA bioassay to detect estrogenic activity in the water cycle.
Nguyen, Mai Thao; van der Oost, Ron; Bovee, Toine F H
2011-12-01
Endocrine disrupting compounds (EDCs) with estrogenic potency contaminate water and might eventually cause adverse effects to the aquatic environment. Many estrogenic compounds are not completely removed by wastewater treatment systems and, together with the run-off from agricultural areas, they enter surface waters. Chemical analytical methods to determine these compounds are usually expensive and laborious. Therefore, screening bioassays which are able to detect compounds based on their effects offer a solution for prior selection of samples that need to be chemically analyzed. In this study, the REA (RIKILT yeast Estrogen bioAssay), which has been developed to detect estrogenic compounds in calf urine and animal feed at RIKILT, is validated at the Water Board Laboratory of Waterproef for water samples. According to EC Decision 2002/657, detection capability CCβ, specificity and stability have to be determined for the internal validation of a qualitative screening test. In addition, surface water and effluent samples were analyzed to further demonstrate the applicability of the validated test procedure. Results demonstrate that the REA assay is reproducible and specific for estrogenic compounds in water and meets the criteria as prescribed in EC Decision 2002/657. The assay was sensitive enough to detect estrogenic activity of pollutants in water with a limit of quantification (LOQ) below 1 ng EEQ/L. This means that samples can be compared with preliminary threshold levels for drinking water and surface waters (7 and 1 ng EEQ/L, respectively). The stability of estrogenic activity in water samples is at least 4 weeks, when stored at 4 °C. Copyright © 2011 Elsevier Ltd. All rights reserved.
Toro, Brigitte; Nester, Christopher J; Farren, Pauline C
2007-03-01
To develop the construct, content, and criterion validity of the Salford Gait Tool (SF-GT) and to evaluate agreement between gait observations using the SF-GT and kinematic gait data. Tool development and comparative evaluation. University in the United Kingdom. For designing construct and content validity, convenience samples of 10 children with hemiplegic, diplegic, and quadriplegic cerebral palsy (CP) and 152 physical therapy students and 4 physical therapists were recruited. For developing criterion validity, kinematic gait data of 13 gait clusters containing 56 children with hemiplegic, diplegic, and quadriplegic CP and 11 neurologically intact children was used. For clinical evaluation, a convenience sample of 23 pediatric physical therapists participated. We developed a sagittal plane observational gait assessment tool through a series of design, test, and redesign iterations. The tool's grading system was calibrated using kinematic gait data of 13 gait clusters and was evaluated by comparing the agreement of gait observations using the SF-GT with kinematic gait data. Criterion standard kinematic gait data. There was 58% mean agreement based on grading categories and 80% mean agreement based on degree estimations evaluated with the least significant difference method. The new SF-GT has good concurrent criterion validity.
Wang, Chang-Hwai; Lee, Jin-Chuan; Yuan, Yu-Hsi
2014-01-01
The purpose of this research is to establish and verify the psychometric and structural properties of the self-report Chinese Sexual Assault Symptom Scale (C-SASS) to assess the trauma experienced by Chinese victims of sexual assault. An earlier version of the C-SASS was constructed using a modified list of the same trauma symptoms administered to an American sample and used to develop and validate the Sexual Assault Symptom Scale II (SASS II). The rationale of this study is to revise the earlier version of the C-SASS, using a larger and more representative sample and more robust statistical analysis than in earlier research, to permit a more thorough examination of the instrument and further confirm the dimensions of sexual assault trauma in Chinese victims of rape. In this study, a sample of 418 victims from northern Taiwan was collected to confirm the reliability and validity of the C-SASS. Exploratory factor analysis yielded five common factors: Safety Fears, Self-Blame, Health Fears, Anger and Emotional Lability, and Fears About the Criminal Justice System. Further tests of the validity and composite reliability of the C-SASS were provided by the structural equation modeling (SEM). The results indicated that the C-SASS was a brief, valid, and reliable instrument for assessing sexual assault trauma among Chinese victims in Taiwan. The scale can be used to evaluate victims in sexual assault treatment centers around Taiwan, as well as to capture the characteristics of sexual assault trauma among Chinese victims.
Mares-García, Emma; Palazón-Bru, Antonio; Folgado-de la Rosa, David Manuel; Pereira-Expósito, Avelino; Martínez-Martín, Álvaro; Cortés-Castell, Ernesto; Gil-Guillén, Vicente Francisco
2017-01-01
Other studies have assessed nonadherence to proton pump inhibitors (PPIs), but none has developed a screening test for its detection. To construct and internally validate a predictive model for nonadherence to PPIs. This prospective observational study with a one-month follow-up was carried out in 2013 in Spain, and included 302 patients with a prescription for PPIs. The primary variable was nonadherence to PPIs (pill count). Secondary variables were gender, age, antidepressants, type of PPI, non-guideline-recommended prescription (NGRP) of PPIs, and total number of drugs. With the secondary variables, a binary logistic regression model to predict nonadherence was constructed and adapted to a points system. The ROC curve, with its area (AUC), was calculated and the optimal cut-off point was established. The points system was internally validated through 1,000 bootstrap samples and implemented in a mobile application (Android). The points system had three prognostic variables: total number of drugs, NGRP of PPIs, and antidepressants. The AUC was 0.87 (95% CI [0.83-0.91], p < 0.001). The test yielded a sensitivity of 0.80 (95% CI [0.70-0.87]) and a specificity of 0.82 (95% CI [0.76-0.87]). The three parameters were very similar in the bootstrap validation. A points system to predict nonadherence to PPIs has been constructed, internally validated and implemented in a mobile application. Provided similar results are obtained in external validation studies, we will have a screening tool to detect nonadherence to PPIs.
Vorberg, Ellen; Fleischer, Heidi; Junginger, Steffen; Liu, Hui; Stoll, Norbert; Thurow, Kerstin
2016-10-01
Life science areas require specific sample pretreatment to increase the concentration of the analytes and/or to convert the analytes into an appropriate form for the detection and separation systems. Various workstations are commercially available, allowing for automated biological sample pretreatment. Nevertheless, due to the required temperature, pressure, and volume conditions in typical element and structure-specific measurements, automated platforms are not suitable for analytical processes. Thus, the purpose of the presented investigation was the design, realization, and evaluation of an automated system ensuring high-precision sample preparation for a variety of analytical measurements. The developed system has to enable system adaption and high performance flexibility. Furthermore, the system has to be capable of dealing with the wide range of required vessels simultaneously, allowing for less cost and time-consuming process steps. However, the system's functionality has been confirmed in various validation sequences. Using element-specific measurements, the automated system was up to 25% more precise compared to the manual procedure and as precise as the manual procedure using structure-specific measurements. © 2015 Society for Laboratory Automation and Screening.
A Study on Critical Thinking Assessment System of College English Writing
ERIC Educational Resources Information Center
Dong, Tian; Yue, Lu
2015-01-01
This research attempts to discuss the validity of introducing the evaluation of students' critical thinking skills (CTS) into the assessment system of college English writing through an empirical study. In this paper, 30 College English Test Band 4 (CET-4) writing samples were collected and analyzed. Students' CTS and the final scores of collected…
Can smartwatches replace smartphones for posture tracking?
Mortazavi, Bobak; Nemati, Ebrahim; VanderWall, Kristina; Flores-Rodriguez, Hector G; Cai, Jun Yu Jacinta; Lucier, Jessica; Naeim, Arash; Sarrafzadeh, Majid
2015-10-22
This paper introduces a human posture tracking platform to identify the human postures of sitting, standing or lying down, based on a smartwatch. This work develops such a system as a proof-of-concept study to investigate a smartwatch's ability to be used in future remote health monitoring systems and applications. This work validates the smartwatches' ability to track the posture of users accurately in a laboratory setting while reducing the sampling rate to potentially improve battery life, the first steps in verifying that such a system would work in future clinical settings. The algorithm developed classifies the transitions between three posture states of sitting, standing and lying down, by identifying these transition movements, as well as other movements that might be mistaken for these transitions. The system is trained and developed on a Samsung Galaxy Gear smartwatch, and the algorithm was validated through a leave-one-subject-out cross-validation of 20 subjects. The system can identify the appropriate transitions at only 10 Hz with an F-score of 0.930, indicating its ability to effectively replace smart phones, if needed.
Malignant Tumors and Forensics – Dilemmas and Proposals
Budimlija, Zoran; Lu, Connie; Axler-DiPerte, Grace; Seifarth, Jessica; Popiolek, Dorota; Fogt, Franz; Prinz, Mechthild
2009-01-01
Aim To evaluate the effect of genetic instability and degradation in archived histology samples from cancerous tumors and to investigate the validity of short tandem repeat (STR) typing of these samples and its potential effect on human identification. Methods Two hundred and twenty eight slides of archival pathology tissues from 13 different types of malignant tumors were compared with healthy tissues from the same individuals. DNA analysis was performed using standard techniques for forensic STR analysis, PowerPlex®16 and Identifiler® on 2 distinct sample sets. Genetic instability was assessed by comparing reference tissues with cancerous tissues derived from the same individual. Loss of heterozygosity, a ≥50% reduction in heterozygosity ratio between healthy and diseased samples, and microsatellite instability, the presence of an additional allele not present in reference tissue, were assessed. The quality of profiles obtained with respect to completeness among the archived samples and degradation using the 2 platforms were also compared. Results Profiles obtained using the Identifiler® system were generally more complete, but showed 3-fold higher levels of instability (86%) than those obtained using PowerPlex® 16 (27%). Instances of genetic instability were distributed throughout all loci in both multiplex STR systems. Conclusion After having compared 2 widely used forensic chemistries, we suggest individual validation of each kit for use with samples likely to exhibit instability combined with fixation induced degradation or artifact. A “one size fits all” approach for interpretation of these samples among commercially available multiplexes is not recommended. PMID:19480018
1993-04-09
according to Bryman , it is possible to use a small sample and still maintain a high degree of validity as long as the sampling size represents a ...Analysis of the Army’s 48 References Alperin, Jeffry A . & St. Germain, Robert A ., Jr. (1989). Open Systems: Ready for Lift-Off? Best Review, 90, 82. Bryman ...8217" Availability Codes • -- a l and I or Dist Spccial*,vai Analysis of the Army’s iii TABLE OF CONTENTS Title Page
Greenspoon, Susan A; Ban, Jeffrey D; Sykes, Karen; Ballard, Elizabeth J; Edler, Shelley S; Baisden, Melissa; Covington, Brian L
2004-01-01
Robotic systems are commonly utilized for the extraction of database samples. However, the application of robotic extraction to forensic casework samples is a more daunting task. Such a system must be versatile enough to accommodate a wide range of samples that may contain greatly varying amounts of DNA, but it must also pose no more risk of contamination than the manual DNA extraction methods. This study demonstrates that the BioMek 2000 Laboratory Automation Workstation, used in combination with the DNA IQ System, is versatile enough to accommodate the wide range of samples typically encountered by a crime laboratory. The use of a silica coated paramagnetic resin, as with the DNA IQ System, facilitates the adaptation of an open well, hands off, robotic system to the extraction of casework samples since no filtration or centrifugation steps are needed. Moreover, the DNA remains tightly coupled to the silica coated paramagnetic resin for the entire process until the elution step. A short pre-extraction incubation step is necessary prior to loading samples onto the robot and it is at this step that most modifications are made to accommodate the different sample types and substrates commonly encountered with forensic evidentiary samples. Sexual assault (mixed stain) samples, cigarette butts, blood stains, buccal swabs, and various tissue samples were successfully extracted with the BioMek 2000 Laboratory Automation Workstation and the DNA IQ System, with no evidence of contamination throughout the extensive validation studies reported here.
A systematic review of the quality of homeopathic clinical trials
Jonas, Wayne B; Anderson, Rachel L; Crawford, Cindy C; Lyons, John S
2001-01-01
Background While a number of reviews of homeopathic clinical trials have been done, all have used methods dependent on allopathic diagnostic classifications foreign to homeopathic practice. In addition, no review has used established and validated quality criteria allowing direct comparison of the allopathic and homeopathic literature. Methods In a systematic review, we compared the quality of clinical-trial research in homeopathy to a sample of research on conventional therapies using a validated and system-neutral approach. All clinical trials on homeopathic treatments with parallel treatment groups published between 1945–1995 in English were selected. All were evaluated with an established set of 33 validity criteria previously validated on a broad range of health interventions across differing medical systems. Criteria covered statistical conclusion, internal, construct and external validity. Reliability of criteria application is greater than 0.95. Results 59 studies met the inclusion criteria. Of these, 79% were from peer-reviewed journals, 29% used a placebo control, 51% used random assignment, and 86% failed to consider potentially confounding variables. The main validity problems were in measurement where 96% did not report the proportion of subjects screened, and 64% did not report attrition rate. 17% of subjects dropped out in studies where this was reported. There was practically no replication of or overlap in the conditions studied and most studies were relatively small and done at a single-site. Compared to research on conventional therapies the overall quality of studies in homeopathy was worse and only slightly improved in more recent years. Conclusions Clinical homeopathic research is clearly in its infancy with most studies using poor sampling and measurement techniques, few subjects, single sites and no replication. Many of these problems are correctable even within a "holistic" paradigm given sufficient research expertise, support and methods. PMID:11801202
Cawello, Willi; Schäfer, Carina
2014-08-01
Frequent plasma sampling to monitor pharmacokinetic (PK) profile of antiepileptic drugs (AEDs), is invasive, costly and time consuming. For drugs with a well-defined PK profile, such as AED lacosamide, equations can accurately approximate PK parameters from one steady-state plasma sample. Equations were derived to approximate steady-state peak and trough lacosamide plasma concentrations (Cpeak,ss and Ctrough,ss, respectively) and area under concentration-time curve during dosing interval (AUCτ,ss) from one plasma sample. Lacosamide (ka: ∼2 h(-1); ke: ∼0.05 h(-1), corresponding to half-life of 13 h) was calculated to reach Cpeak,ss after ∼1 h (tmax,ss). Equations were validated by comparing approximations to reference PK parameters obtained from single plasma samples drawn 3-12h following lacosamide administration, using data from double-blind, placebo-controlled, parallel-group PK study. Values of relative bias (accuracy) between -15% and +15%, and root mean square error (RMSE) values≤15% (precision) were considered acceptable for validation. Thirty-five healthy subjects (12 young males; 11 elderly males, 12 elderly females) received lacosamide 100mg/day for 4.5 days. Equation-derived PK values were compared to reference mean Cpeak,ss, Ctrough,ss and AUCτ,ss values. Equation-derived PK data had a precision of 6.2% and accuracy of -8.0%, 2.9%, and -0.11%, respectively. Equation-derived versus reference PK values for individual samples obtained 3-12h after lacosamide administration showed correlation (R2) range of 0.88-0.97 for AUCτ,ss. Correlation range for Cpeak,ss and Ctrough,ss was 0.65-0.87. Error analyses for individual sample comparisons were independent of time. Derived equations approximated lacosamide Cpeak,ss, Ctrough,ss and AUCτ,ss using one steady-state plasma sample within validation range. Approximated PK parameters were within accepted validation criteria when compared to reference PK values. Copyright © 2014 Elsevier B.V. All rights reserved.
Low-sensitivity H ∞ filter design for linear delta operator systems with sampling time jitter
NASA Astrophysics Data System (ADS)
Guo, Xiang-Gui; Yang, Guang-Hong
2012-04-01
This article is concerned with the problem of designing H ∞ filters for a class of linear discrete-time systems with low-sensitivity to sampling time jitter via delta operator approach. Delta-domain model is used to avoid the inherent numerical ill-condition resulting from the use of the standard shift-domain model at high sampling rates. Based on projection lemma in combination with the descriptor system approach often used to solve problems related to delay, a novel bounded real lemma with three slack variables for delta operator systems is presented. A sensitivity approach based on this novel lemma is proposed to mitigate the effects of sampling time jitter on system performance. Then, the problem of designing a low-sensitivity filter can be reduced to a convex optimisation problem. An important consideration in the design of correlation filters is the optimal trade-off between the standard H ∞ criterion and the sensitivity of the transfer function with respect to sampling time jitter. Finally, a numerical example demonstrating the validity of the proposed design method is given.
The Resilience Scale for Adults: Construct Validity and Measurement in a Belgian Sample
ERIC Educational Resources Information Center
Hjemdal, Odin; Friborg, Oddgeir; Braun, Stephanie; Kempenaers, Chantal; Linkowski, Paul; Fossion, Pierre
2011-01-01
The Resilience Scale for Adults (RSA) was developed and has been extensively validated in Norwegian samples. The purpose of this study was to explore the construct validity of the Resilience Scale for Adults in a French-speaking Belgian sample and test measurement invariance between the Belgian and a Norwegian sample. A Belgian student sample (N =…
Numerical simulation and analysis for low-frequency rock physics measurements
NASA Astrophysics Data System (ADS)
Dong, Chunhui; Tang, Genyang; Wang, Shangxu; He, Yanxiao
2017-10-01
In recent years, several experimental methods have been introduced to measure the elastic parameters of rocks in the relatively low-frequency range, such as differential acoustic resonance spectroscopy (DARS) and stress-strain measurement. It is necessary to verify the validity and feasibility of the applied measurement method and to quantify the sources and levels of measurement error. Relying solely on the laboratory measurements, however, we cannot evaluate the complete wavefield variation in the apparatus. Numerical simulations of elastic wave propagation, on the other hand, are used to model the wavefield distribution and physical processes in the measurement systems, and to verify the measurement theory and analyze the measurement results. In this paper we provide a numerical simulation method to investigate the acoustic waveform response of the DARS system and the quasi-static responses of the stress-strain system, both of which use axisymmetric apparatus. We applied this method to parameterize the properties of the rock samples, the sample locations and the sensor (hydrophone and strain gauges) locations and simulate the measurement results, i.e. resonance frequencies and axial and radial strains on the sample surface, from the modeled wavefield following the physical experiments. Rock physical parameters were estimated by inversion or direct processing of these data, and showed a perfect match with the true values, thus verifying the validity of the experimental measurements. Error analysis was also conducted for the DARS system with 18 numerical samples, and the sources and levels of error are discussed. In particular, we propose an inversion method for estimating both density and compressibility of these samples. The modeled results also showed fairly good agreement with the real experiment results, justifying the effectiveness and feasibility of our modeling method.
NASA Astrophysics Data System (ADS)
Lu, Zenghai; Kasaragod, Deepa K.; Matcher, Stephen J.
2012-01-01
We demonstrate theoretically and experimentally that the phase retardance and relative optic-axis orientation of a sample can be calculated without prior knowledge of the actual value of the phase modulation amplitude when using a polarization-sensitive optical coherence tomography system based on continuous polarization modulation (CPM-PS-OCT). We also demonstrate that the sample Jones matrix can be calculated at any values of the phase modulation amplitude in a reasonable range depending on the system effective signal-to-noise ratio. This has fundamental importance for the development of clinical systems by simplifying the polarization modulator drive instrumentation and eliminating its calibration procedure. This was validated on measurements of a three-quarter waveplate and an equine tendon sample by a fiber-based swept-source CPM-PS-OCT system.
Massively parallel digital transcriptional profiling of single cells
Zheng, Grace X. Y.; Terry, Jessica M.; Belgrader, Phillip; Ryvkin, Paul; Bent, Zachary W.; Wilson, Ryan; Ziraldo, Solongo B.; Wheeler, Tobias D.; McDermott, Geoff P.; Zhu, Junjie; Gregory, Mark T.; Shuga, Joe; Montesclaros, Luz; Underwood, Jason G.; Masquelier, Donald A.; Nishimura, Stefanie Y.; Schnall-Levin, Michael; Wyatt, Paul W.; Hindson, Christopher M.; Bharadwaj, Rajiv; Wong, Alexander; Ness, Kevin D.; Beppu, Lan W.; Deeg, H. Joachim; McFarland, Christopher; Loeb, Keith R.; Valente, William J.; Ericson, Nolan G.; Stevens, Emily A.; Radich, Jerald P.; Mikkelsen, Tarjei S.; Hindson, Benjamin J.; Bielas, Jason H.
2017-01-01
Characterizing the transcriptome of individual cells is fundamental to understanding complex biological systems. We describe a droplet-based system that enables 3′ mRNA counting of tens of thousands of single cells per sample. Cell encapsulation, of up to 8 samples at a time, takes place in ∼6 min, with ∼50% cell capture efficiency. To demonstrate the system's technical performance, we collected transcriptome data from ∼250k single cells across 29 samples. We validated the sensitivity of the system and its ability to detect rare populations using cell lines and synthetic RNAs. We profiled 68k peripheral blood mononuclear cells to demonstrate the system's ability to characterize large immune populations. Finally, we used sequence variation in the transcriptome data to determine host and donor chimerism at single-cell resolution from bone marrow mononuclear cells isolated from transplant patients. PMID:28091601
Hird, H J; Brown, M K
2017-11-01
The identification of samples at a crime scene which require forensic DNA typing has been the focus of recent research interest. We propose a simple, but sensitive analysis system which can be deployed at a crime scene to identify crime scene stains as human or non-human. The proposed system uses the isothermal amplification of DNA in a rapid assay format, which returns results in as little as 30min from sampling. The assay system runs on the Genie II device, a proven in-field detection system which could be deployed at a crime scene. The results presented here demonstrate that the system was sufficiently specific and sensitive and was able to detect the presence of human blood, semen and saliva on mock forensic samples. Copyright © 2017. Published by Elsevier B.V.
Houston, Rachel; Birck, Matthew; Hughes-Stamm, Sheree; Gangitano, David
2017-05-01
Marijuana (Cannabis sativa L.) is a plant cultivated and trafficked worldwide as a source of fiber (hemp), medicine, and intoxicant. The development of a validated method using molecular techniques such as short tandem repeats (STRs) could serve as an intelligence tool to link multiple cases by means of genetic individualization or association of cannabis samples. For this purpose, a 13 loci STR multiplex method was developed, optimized, and validated according to relevant ISFG and SWGDAM guidelines. The STR multiplex consists of 13 previously described C. sativa STR loci: ANUCS501, 9269, 4910, 5159, ANUCS305, 9043, B05, 1528, 3735, CS1, D02, C11, and H06. A sequenced allelic ladder consisting of 56 alleles was designed to accurately genotype 101 C. sativa samples from three seizures provided by a U.S. Customs and Border Protection crime lab. Using an optimal range of DNA (0.5-1.0ng), validation studies revealed well-balanced electropherograms (inter-locus balance range: 0.500-1.296), relatively balanced heterozygous peaks (mean peak height ratio of 0.83 across all loci) with minimal artifacts and stutter ratio (mean stutter of 0.021 across all loci). This multi-locus system is relatively sensitive (0.13ng of template DNA) with a combined power of discrimination of 1 in 55 million. The 13 STR panel was found to be species specific for C. sativa; however, non-specific peaks were produced with Humulus lupulus. The results of this research demonstrate the robustness and applicability of this 13 loci STR system for forensic DNA profiling of marijuana samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Rossi, Francesca; Petrucci, Maria Teresa; Guffanti, Andrea; Marcheselli, Luigi; Rossi, Davide; Callea, Vincenzo; Vincenzo, Federico; De Muro, Marianna; Baraldi, Alessandra; Villani, Oreste; Musto, Pellegrino; Bacigalupo, Andrea; Gaidano, Gianluca; Avvisati, Giuseppe; Goldaniga, Maria; Depaoli, Lorenzo; Baldini, Luca
2009-07-01
The presenting clinico-hematologic features of 1,283 patients with IgG and IgA monoclonal gammopathies of undetermined significance (MGUS) were correlated with the frequency of evolution into multiple myeloma (MM). Two IgG MGUS populations were evaluated: a training sample (553 patients) and a test sample (378 patients); the IgA MGUS population consisted of 352 patients. Forty-seven of the 553 training group patients and 22 of 378 test group IgG patients developed MM after a median follow-up of 6.7 and 3.6 years, respectively. Multivariate analysis showed that serum monoclonal component (MC) levels of < or =1.5 g/dL, the absence of light-chain proteinuria and normal serum polyclonal immunoglobulin levels defined a prognostically favorable subset of patients, and could be used to stratify the patients into three groups at different 10-year risk of evolution (hazard ratio, 1.0, 5.04, 11.2; P < 0.001). This scoring system was validated in the test sample. Thirty of the 352 IgA patients developed MM after a median follow-up of 4.8 years, and multivariate analysis showed that hemoglobin levels of <12.5 g/dL and reduced serum polyclonal immunoglobulin correlated with progression. A pooled statistical analysis of all of the patients confirmed the validity of Mayo Clinic risk model showing that IgA class, serum MC levels, and light-chain proteinuria are the most important variables correlated with disease progression. Using simple variables, we validated a prognostic model for IgG MGUS. Among the IgA cases, the possible prognostic role of hemoglobin emerged in addition to a decrease in normal immunoglobulin levels.
Real-Time PCR Method for Detection of Salmonella spp. in Environmental Samples
Drgon, Tomas
2017-01-01
ABSTRACT The methods currently used for detecting Salmonella in environmental samples require 2 days to produce results and have limited sensitivity. Here, we describe the development and validation of a real-time PCR Salmonella screening method that produces results in 18 to 24 h. Primers and probes specific to the gene invA, group D, and Salmonella enterica serovar Enteritidis organisms were designed and evaluated for inclusivity and exclusivity using a panel of 329 Salmonella isolates representing 126 serovars and 22 non-Salmonella organisms. The invA- and group D-specific sets identified all the isolates accurately. The PCR method had 100% inclusivity and detected 1 to 2 copies of Salmonella DNA per reaction. Primers specific for Salmonella-differentiating fragment 1 (Sdf-1) in conjunction with the group D set had 100% inclusivity for 32 S. Enteritidis isolates and 100% exclusivity for the 297 non-Enteritidis Salmonella isolates. Single-laboratory validation performed on 1,741 environmental samples demonstrated that the PCR method detected 55% more positives than the Vitek immunodiagnostic assay system (VIDAS) method. The PCR results correlated well with the culture results, and the method did not report any false-negative results. The receiver operating characteristic (ROC) analysis documented excellent agreement between the results from the culture and PCR methods (area under the curve, 0.90; 95% confidence interval of 0.76 to 1.0) confirming the validity of the PCR method. IMPORTANCE This validated PCR method detects 55% more positives for Salmonella in half the time required for the reference method, VIDAS. The validated PCR method will help to strengthen public health efforts through rapid screening of Salmonella spp. in environmental samples. PMID:28500041
A Sequential Optimization Sampling Method for Metamodels with Radial Basis Functions
Pan, Guang; Ye, Pengcheng; Yang, Zhidong
2014-01-01
Metamodels have been widely used in engineering design to facilitate analysis and optimization of complex systems that involve computationally expensive simulation programs. The accuracy of metamodels is strongly affected by the sampling methods. In this paper, a new sequential optimization sampling method is proposed. Based on the new sampling method, metamodels can be constructed repeatedly through the addition of sampling points, namely, extrema points of metamodels and minimum points of density function. Afterwards, the more accurate metamodels would be constructed by the procedure above. The validity and effectiveness of proposed sampling method are examined by studying typical numerical examples. PMID:25133206
High-Definition Infrared Spectroscopic Imaging
Reddy, Rohith K.; Walsh, Michael J.; Schulmerich, Matthew V.; Carney, P. Scott; Bhargava, Rohit
2013-01-01
The quality of images from an infrared (IR) microscope has traditionally been limited by considerations of throughput and signal-to-noise ratio (SNR). An understanding of the achievable quality as a function of instrument parameters, from first principals is needed for improved instrument design. Here, we first present a model for light propagation through an IR spectroscopic imaging system based on scalar wave theory. The model analytically describes the propagation of light along the entire beam path from the source to the detector. The effect of various optical elements and the sample in the microscope is understood in terms of the accessible spatial frequencies by using a Fourier optics approach and simulations are conducted to gain insights into spectroscopic image formation. The optimal pixel size at the sample plane is calculated and shown much smaller than that in current mid-IR microscopy systems. A commercial imaging system is modified, and experimental data are presented to demonstrate the validity of the developed model. Building on this validated theoretical foundation, an optimal sampling configuration is set up. Acquired data were of high spatial quality but, as expected, of poorer SNR. Signal processing approaches were implemented to improve the spectral SNR. The resulting data demonstrated the ability to perform high-definition IR imaging in the laboratory by using minimally-modified commercial instruments. PMID:23317676
High-definition infrared spectroscopic imaging.
Reddy, Rohith K; Walsh, Michael J; Schulmerich, Matthew V; Carney, P Scott; Bhargava, Rohit
2013-01-01
The quality of images from an infrared (IR) microscope has traditionally been limited by considerations of throughput and signal-to-noise ratio (SNR). An understanding of the achievable quality as a function of instrument parameters, from first principals is needed for improved instrument design. Here, we first present a model for light propagation through an IR spectroscopic imaging system based on scalar wave theory. The model analytically describes the propagation of light along the entire beam path from the source to the detector. The effect of various optical elements and the sample in the microscope is understood in terms of the accessible spatial frequencies by using a Fourier optics approach and simulations are conducted to gain insights into spectroscopic image formation. The optimal pixel size at the sample plane is calculated and shown much smaller than that in current mid-IR microscopy systems. A commercial imaging system is modified, and experimental data are presented to demonstrate the validity of the developed model. Building on this validated theoretical foundation, an optimal sampling configuration is set up. Acquired data were of high spatial quality but, as expected, of poorer SNR. Signal processing approaches were implemented to improve the spectral SNR. The resulting data demonstrated the ability to perform high-definition IR imaging in the laboratory by using minimally-modified commercial instruments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Linard, Joshua; Price, Jeffrey
This event included annual sampling of groundwater and surface water locations at the Green River, Utah, Disposal Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for US. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lrnldownloads/sampling-and- analysis-plan-us-department-energy-office-legacy-management-sites). Samples were collected from 15 monitoring wells and two surface locations at the disposal site as specified in the draft 2011 Ground Water Compliance Action Plan for the Green River, Utah, Disposal Site. Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. A duplicate sample was collected from location 0179. Onemore » equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. See Attachment 2, Trip Reports for additional details. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. No issues were identified during the data validation process that requires additional action or follow-up.« less
Bahrdt, C; Krech, A B; Wurz, A; Wulff, D
2010-03-01
For years, an increasing number and diversity of genetically modified plants has been grown on a commercial scale. The need for detection and identification of these genetically modified organisms (GMOs) calls for broad and at the same time flexible high throughput testing methods. Here we describe the development and validation of a hexaplex real-time polymerase chain reaction (PCR) screening assay covering more than 100 approved GMOs containing at least one of the GMO targets of the assay. The assay comprises detection systems for Cauliflower Mosaic Virus 35S promoter, Agrobacterium tumefaciens NOS terminator, Figwort Mosaic Virus 34S promoter and two construct-specific sequences present in novel genetically modified soybean and maize that lack common screening elements. Additionally a detection system for an internal positive control (IPC) indicating the presence or absence of PCR inhibiting substances was included. The six real-time PCR systems were allocated to five detection channels showing no significant crosstalk between the detection channels. As part of an extensive validation, a limit of detection (LOD(abs)) < or = ten target copies was proven in hexaplex format. A sensitivity < or = ten target copies of each GMO detection system was still shown in highly asymmetric target situations in the presence of 1,000 copies of all other GMO targets of each detection channel. Furthermore, the applicability to a broad sample spectrum and reliable indication of inhibition by the IPC system was demonstrated. The presented hexaplex assay offers sensitive and reliable detection of GMOs in processed and unprocessed food, feed and seed samples with high efficiency.
Wen, Kuang-Yi; Gustafson, David H; Hawkins, Robert P; Brennan, Patricia F; Dinauer, Susan; Johnson, Pauley R; Siegler, Tracy
2010-01-01
To develop and validate the Readiness for Implementation Model (RIM). This model predicts a healthcare organization's potential for success in implementing an interactive health communication system (IHCS). The model consists of seven weighted factors, with each factor containing five to seven elements. Two decision-analytic approaches, self-explicated and conjoint analysis, were used to measure the weights of the RIM with a sample of 410 experts. The RIM model with weights was then validated in a prospective study of 25 IHCS implementation cases. Orthogonal main effects design was used to develop 700 conjoint-analysis profiles, which varied on seven factors. Each of the 410 experts rated the importance and desirability of the factors and their levels, as well as a set of 10 different profiles. For the prospective 25-case validation, three time-repeated measures of the RIM scores were collected for comparison with the implementation outcomes. Two of the seven factors, 'organizational motivation' and 'meeting user needs,' were found to be most important in predicting implementation readiness. No statistically significant difference was found in the predictive validity of the two approaches (self-explicated and conjoint analysis). The RIM was a better predictor for the 1-year implementation outcome than the half-year outcome. The expert sample, the order of the survey tasks, the additive model, and basing the RIM cut-off score on experience are possible limitations of the study. The RIM needs to be empirically evaluated in institutions adopting IHCS and sustaining the system in the long term.
Abramyan, Tigran M.; Hyde-Volpe, David L.; Stuart, Steven J.; Latour, Robert A.
2017-01-01
The use of standard molecular dynamics simulation methods to predict the interactions of a protein with a material surface have the inherent limitations of lacking the ability to determine the most likely conformations and orientations of the adsorbed protein on the surface and to determine the level of convergence attained by the simulation. In addition, standard mixing rules are typically applied to combine the nonbonded force field parameters of the solution and solid phases the system to represent interfacial behavior without validation. As a means to circumvent these problems, the authors demonstrate the application of an efficient advanced sampling method (TIGER2A) for the simulation of the adsorption of hen egg-white lysozyme on a crystalline (110) high-density polyethylene surface plane. Simulations are conducted to generate a Boltzmann-weighted ensemble of sampled states using force field parameters that were validated to represent interfacial behavior for this system. The resulting ensembles of sampled states were then analyzed using an in-house-developed cluster analysis method to predict the most probable orientations and conformations of the protein on the surface based on the amount of sampling performed, from which free energy differences between the adsorbed states were able to be calculated. In addition, by conducting two independent sets of TIGER2A simulations combined with cluster analyses, the authors demonstrate a method to estimate the degree of convergence achieved for a given amount of sampling. The results from these simulations demonstrate that these methods enable the most probable orientations and conformations of an adsorbed protein to be predicted and that the use of our validated interfacial force field parameter set provides closer agreement to available experimental results compared to using standard CHARMM force field parameterization to represent molecular behavior at the interface. PMID:28514864
Peñarrubia, Luis; Alcaraz, Carles; Vaate, Abraham Bij de; Sanz, Nuria; Pla, Carles; Vidal, Oriol; Viñas, Jordi
2016-12-14
The zebra mussel (Dreissena polymorpha Pallas, 1771) and the quagga mussel (D. rostriformis Deshayes, 1838) are successful invasive bivalves with substantial ecological and economic impacts in freshwater systems once they become established. Since their eradication is extremely difficult, their detection at an early stage is crucial to prevent spread. In this study, we optimized and validated a qPCR detection method based on the histone H2B gene to quantify combined infestation levels of zebra and quagga mussels in environmental DNA samples. Our results show specific dreissenid DNA present in filtered water samples for which microscopic diagnostic identification for larvae failed. Monitoring a large number of locations for invasive dreissenid species based on a highly specific environmental DNA qPCR assay may prove to be an essential tool for management and control plans focused on prevention of establishment of dreissenid mussels in new locations.
Peñarrubia, Luis; Alcaraz, Carles; Vaate, Abraham bij de; Sanz, Nuria; Pla, Carles; Vidal, Oriol; Viñas, Jordi
2016-01-01
The zebra mussel (Dreissena polymorpha Pallas, 1771) and the quagga mussel (D. rostriformis Deshayes, 1838) are successful invasive bivalves with substantial ecological and economic impacts in freshwater systems once they become established. Since their eradication is extremely difficult, their detection at an early stage is crucial to prevent spread. In this study, we optimized and validated a qPCR detection method based on the histone H2B gene to quantify combined infestation levels of zebra and quagga mussels in environmental DNA samples. Our results show specific dreissenid DNA present in filtered water samples for which microscopic diagnostic identification for larvae failed. Monitoring a large number of locations for invasive dreissenid species based on a highly specific environmental DNA qPCR assay may prove to be an essential tool for management and control plans focused on prevention of establishment of dreissenid mussels in new locations. PMID:27966602
2013-09-01
through direct sampling of form and content of critical display data. Evidence of construct validity is provided by correlation with the Colour ...measured by the Colour Assessment and Diagnosis (CAD; ARTS Background Colors STARS Background Colors ERAM Background Colors Figure 3...Gelade, G. (1980). A feature-integration theory of attention. Cognitive Psychology , 12, 97–136. Xing, J. & Schroeder, D.J. (2006). Reexamination of
Wong, Anita A; Pabbaraju, Kanti; Wong, Sallene; Tellier, Raymond
2016-03-01
Herpes simplex viruses (HSV) and varicella zoster virus (VZV) can have very similar and wide-ranging clinical presentations. Rapid identification is necessary for timely antiviral therapy, especially with infections involving the central nervous system, neonates, and immunocompromised individuals. Detection of HSV-1, HSV-2 and VZV was combined into one real-time PCR reaction utilizing hydrolysis probes. The assay was validated on the LightCycler(®) (Roche) and Applied Biosystems 7500 Real-Time PCR System (Thermo Fisher Scientific Inc.) to detect alphaherpesviruses in cerebral spinal fluid (CSF) and lesion swab specimens, respectively. Validation data on blood and tissue samples are also presented. The multiplex assay showed excellent sensitivity, specificity and reproducibility when compared to two singleplex real-time PCR assays for CSF samples and direct fluorescent antigen/culture for lesion swab samples. Implementation of the multiplex assay has facilitated improved sensitivity and accuracy as well as reduced turn-around-times and costs. The results from a large data set of 16,622 prospective samples tested between August 16, 2012 to February 1, 2014 at the Provincial Laboratory for Public Health (Alberta, Canada) are presented here. Copyright © 2015 Elsevier B.V. All rights reserved.
Swab or biopsy samples for bioburden testing of allograft musculoskeletal tissue?
Varettas, Kerry
2014-12-01
Swab and biopsy samples of allograft musculoskeletal tissue are most commonly collected by tissue banks for bacterial and fungal bioburden testing. An in vitro study was performed using the National Committee for Clinical Laboratory Standards standard 'Quality control of microbiological transport systems' (2003) to validate and evaluate the recovery of six challenge organisms from swab and biopsy samples of allograft musculoskeletal tissue. On average, 8.4 to >100 and 7.2 to >100 % of the inoculum was recovered from swab and biopsy samples respectively. A retrospective review of donor episodes was also performed, consisting of paired swab and biopsy samples received in this laboratory during the period 2001-2012. Samples of allograft femoral heads were collected from living donors during hip operations. From the 3,859 donor episodes received, 21 paired swab and biopsy samples each recovered an isolate, 247 swab samples only and 79 biopsy samples only were culture positive. Low numbers of challenge organisms were recovered from inoculated swab and biopsy samples in the in vitro study and validated their use for bioburden testing of allograft musculoskeletal tissue. Skin commensals were the most common group of organisms isolated during a 12-year retrospective review of paired swab and biopsy samples from living donor allograft femoral heads. Paired swab and biopsy samples are a suitable representative sample of allograft musculoskeletal tissue for bioburden testing.
ERIC Educational Resources Information Center
Fjermestad, Krister W.; McLeod, Bryce D.; Heiervang, Einar R.; Havik, Odd E.; Ost, Lars-Goran; Haugland, Bente S. M.
2012-01-01
The aim of this study was to examine the factor structure and psychometric properties of an observer-rated youth alliance measure, the Therapy Process Observational Coding System for Child Psychotherapy-Alliance scale (TPOCS-A). The sample was 52 youth diagnosed with anxiety disorders ("M" age = 12.43, "SD" = 2.23, range = 15;…
ERIC Educational Resources Information Center
Oh, Hunseok; Choi, Yeseul; Choi, Myungweon
2013-01-01
The purpose of this study was to assess, evaluate, and compare the competitive advantages of the human resource development systems of advanced countries. The Global Human Resource Development Index was utilized for this study, since it has been validated through an expert panel's content review and analytic hierarchy process. Using a sample of 34…
Spatial-temporal discriminant analysis for ERP-based brain-computer interface.
Zhang, Yu; Zhou, Guoxu; Zhao, Qibin; Jin, Jing; Wang, Xingyu; Cichocki, Andrzej
2013-03-01
Linear discriminant analysis (LDA) has been widely adopted to classify event-related potential (ERP) in brain-computer interface (BCI). Good classification performance of the ERP-based BCI usually requires sufficient data recordings for effective training of the LDA classifier, and hence a long system calibration time which however may depress the system practicability and cause the users resistance to the BCI system. In this study, we introduce a spatial-temporal discriminant analysis (STDA) to ERP classification. As a multiway extension of the LDA, the STDA method tries to maximize the discriminant information between target and nontarget classes through finding two projection matrices from spatial and temporal dimensions collaboratively, which reduces effectively the feature dimensionality in the discriminant analysis, and hence decreases significantly the number of required training samples. The proposed STDA method was validated with dataset II of the BCI Competition III and dataset recorded from our own experiments, and compared to the state-of-the-art algorithms for ERP classification. Online experiments were additionally implemented for the validation. The superior classification performance in using few training samples shows that the STDA is effective to reduce the system calibration time and improve the classification accuracy, thereby enhancing the practicability of ERP-based BCI.
NASA Astrophysics Data System (ADS)
Kassem, A.; Sawan, M.; Boukadoum, M.; Haidar, A.
2005-12-01
We are concerned with the design, implementation, and validation of a perception SoC based on an ultrasonic array of sensors. The proposed SoC is dedicated to ultrasonic echography applications. A rapid prototyping platform is used to implement and validate the new architecture of the digital signal processing (DSP) core. The proposed DSP core efficiently integrates all of the necessary ultrasonic B-mode processing modules. It includes digital beamforming, quadrature demodulation of RF signals, digital filtering, and envelope detection of the received signals. This system handles 128 scan lines and 6400 samples per scan line with a[InlineEquation not available: see fulltext.] angle of view span. The design uses a minimum size lookup memory to store the initial scan information. Rapid prototyping using an ARM/FPGA combination is used to validate the operation of the described system. This system offers significant advantages of portability and a rapid time to market.
Feng, Xing-Ling; Sun, Qi-Fan; Liu, Hong; Wei, Yi-Liang; DU, Wei-An; Li, Cai-Xia; Chen, Ling; Liu, Chao
2016-04-20
To validate the efficiency of 27-plex single nucleotide polymorphism (SNP) multiplex system for ancestry inference. The 27-plex SNP system was validated for its sensitivity and species specificity. A total of 533 samples were collected from African, Southern Chinese Han, China's ethic minorities (Yi, Hui, Miao, Tibet, and Uygur), European, Central Asian, Western Asian, Southern Asian, Southeast Asian and South American populations for clustering analysis of the genotypes by citing 3 representative continental ancestral groups [East Asia (CHB), Europe (CEU), and Africa (YRI)] from HapMap database. The system sensitivity is 0.125 ng. Twenty and six genotypes were detected in chimpanzee and monkeys, respectively. Except in rs10496971, no more products were found in other animals. The system was capable of differentiating intercontinental populations but not of distinguishing between East Asian and Southeast Asian population or between Southern Chinese Han population and Chinese Ethnic populations (Hui, Miao, Yi and Tibet). This system achieved a 100% accuracy for intercontinental population source inference for 46 blind test samples. 27-plex SNPs multiplex system has a high sensitivity and species specificity and can correctly differentiate the ancestry origins of individuals from African, European and East Asian for criminal case investigation. But this system is not capable of distinguishing subpopulation groups and more specific ancestry-informative markers are needed to improve its recognition of Southeast Asian and Chinese ethnic populations.
Ort, Christoph; Lawrence, Michael G; Rieckermann, Jörg; Joss, Adriano
2010-08-15
The analysis of 87 peer-reviewed journal articles reveals that sampling for pharmaceuticals and personal care products (PPCPs) and illicit drugs in sewers and sewage treatment plant influents is mostly carried out according to existing tradition or standard laboratory protocols. Less than 5% of all studies explicitly consider internationally acknowledged guidelines or methods for the experimental design of monitoring campaigns. In the absence of a proper analysis of the system under investigation, the importance of short-term pollutant variations was typically not addressed. Therefore, due to relatively long sampling intervals, potentially inadequate sampling modes, or insufficient documentation, it remains unclear for the majority of reviewed studies whether observed variations can be attributed to "real" variations or if they simply reflect sampling artifacts. Based on results from previous and current work, the present paper demonstrates that sampling errors can lead to overinterpretation of measured data and ultimately, wrong conclusions. Depending on catchment size, sewer type, sampling setup, substance of interest, and accuracy of analytical method, avoidable sampling artifacts can range from "not significant" to "100% or more" for different compounds even within the same study. However, in most situations sampling errors can be reduced greatly, and sampling biases can be eliminated completely, by choosing an appropriate sampling mode and frequency. This is crucial, because proper sampling will help to maximize the value of measured data for the experimental assessment of the fate of PPCPs as well as for the formulation and validation of mathematical models. The trend from reporting presence or absence of a compound in "clean" water samples toward the quantification of PPCPs in raw wastewater requires not only sophisticated analytical methods but also adapted sampling methods. With increasing accuracy of chemical analyses, inappropriate sampling increasingly represents the major source of inaccuracy. A condensed step-by-step Sampling Guide is proposed as a starting point for future studies.
Sampling algorithms for validation of supervised learning models for Ising-like systems
NASA Astrophysics Data System (ADS)
Portman, Nataliya; Tamblyn, Isaac
2017-12-01
In this paper, we build and explore supervised learning models of ferromagnetic system behavior, using Monte-Carlo sampling of the spin configuration space generated by the 2D Ising model. Given the enormous size of the space of all possible Ising model realizations, the question arises as to how to choose a reasonable number of samples that will form physically meaningful and non-intersecting training and testing datasets. Here, we propose a sampling technique called ;ID-MH; that uses the Metropolis-Hastings algorithm creating Markov process across energy levels within the predefined configuration subspace. We show that application of this method retains phase transitions in both training and testing datasets and serves the purpose of validation of a machine learning algorithm. For larger lattice dimensions, ID-MH is not feasible as it requires knowledge of the complete configuration space. As such, we develop a new ;block-ID; sampling strategy: it decomposes the given structure into square blocks with lattice dimension N ≤ 5 and uses ID-MH sampling of candidate blocks. Further comparison of the performance of commonly used machine learning methods such as random forests, decision trees, k nearest neighbors and artificial neural networks shows that the PCA-based Decision Tree regressor is the most accurate predictor of magnetizations of the Ising model. For energies, however, the accuracy of prediction is not satisfactory, highlighting the need to consider more algorithmically complex methods (e.g., deep learning).
Do placebo based validation standards mimic real batch products behaviour? Case studies.
Bouabidi, A; Talbi, M; Bouklouze, A; El Karbane, M; Bourichi, H; El Guezzar, M; Ziemons, E; Hubert, Ph; Rozet, E
2011-06-01
Analytical methods validation is a mandatory step to evaluate the ability of developed methods to provide accurate results for their routine application. Validation usually involves validation standards or quality control samples that are prepared in placebo or reconstituted matrix made of a mixture of all the ingredients composing the drug product except the active substance or the analyte under investigation. However, one of the main concerns that can be made with this approach is that it may lack an important source of variability that come from the manufacturing process. The question that remains at the end of the validation step is about the transferability of the quantitative performance from validation standards to real authentic drug product samples. In this work, this topic is investigated through three case studies. Three analytical methods were validated using the commonly spiked placebo validation standards at several concentration levels as well as using samples coming from authentic batch samples (tablets and syrups). The results showed that, depending on the type of response function used as calibration curve, there were various degrees of differences in the results accuracy obtained with the two types of samples. Nonetheless the use of spiked placebo validation standards was showed to mimic relatively well the quantitative behaviour of the analytical methods with authentic batch samples. Adding these authentic batch samples into the validation design may help the analyst to select and confirm the most fit for purpose calibration curve and thus increase the accuracy and reliability of the results generated by the method in routine application. Copyright © 2011 Elsevier B.V. All rights reserved.
Flores, Shahida; Sun, Jie; King, Jonathan; Budowle, Bruce
2014-05-01
The GlobalFiler™ Express PCR Amplification Kit uses 6-dye fluorescent chemistry to enable multiplexing of 21 autosomal STRs, 1 Y-STR, 1 Y-indel and the sex-determining marker amelogenin. The kit is specifically designed for processing reference DNA samples in a high throughput manner. Validation studies were conducted to assess the performance and define the limitations of this direct amplification kit for typing blood and buccal reference DNA samples on various punchable collection media. Studies included thermal cycling sensitivity, reproducibility, precision, sensitivity of detection, minimum detection threshold, system contamination, stochastic threshold and concordance. Results showed that optimal amplification and injection parameters for a 1.2mm punch from blood and buccal samples were 27 and 28 cycles, respectively, combined with a 12s injection on an ABI 3500xL Genetic Analyzer. Minimum detection thresholds were set at 100 and 120RFUs for 27 and 28 cycles, respectively, and it was suggested that data from positive amplification controls provided a better threshold representation. Stochastic thresholds were set at 250 and 400RFUs for 27 and 28 cycles, respectively, as stochastic effects increased with cycle number. The minimum amount of input DNA resulting in a full profile was 0.5ng, however, the optimum range determined was 2.5-10ng. Profile quality from the GlobalFiler™ Express Kit and the previously validated AmpFlSTR(®) Identifiler(®) Direct Kit was comparable. The validation data support that reliable DNA typing results from reference DNA samples can be obtained using the GlobalFiler™ Express PCR Amplification Kit. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Tseng, Hsin-Wu; Fan, Jiahua; Kupinski, Matthew A.
2016-01-01
Abstract. The use of a channelization mechanism on model observers not only makes mimicking human visual behavior possible, but also reduces the amount of image data needed to estimate the model observer parameters. The channelized Hotelling observer (CHO) and channelized scanning linear observer (CSLO) have recently been used to assess CT image quality for detection tasks and combined detection/estimation tasks, respectively. Although the use of channels substantially reduces the amount of data required to compute image quality, the number of scans required for CT imaging is still not practical for routine use. It is our desire to further reduce the number of scans required to make CHO or CSLO an image quality tool for routine and frequent system validations and evaluations. This work explores different data-reduction schemes and designs an approach that requires only a few CT scans. Three different kinds of approaches are included in this study: a conventional CHO/CSLO technique with a large sample size, a conventional CHO/CSLO technique with fewer samples, and an approach that we will show requires fewer samples to mimic conventional performance with a large sample size. The mean value and standard deviation of areas under ROC/EROC curve were estimated using the well-validated shuffle approach. The results indicate that an 80% data reduction can be achieved without loss of accuracy. This substantial data reduction is a step toward a practical tool for routine-task-based QA/QC CT system assessment. PMID:27493982
FDTD based model of ISOCT imaging for validation of nanoscale sensitivity (Conference Presentation)
NASA Astrophysics Data System (ADS)
Eid, Aya; Zhang, Di; Yi, Ji; Backman, Vadim
2017-02-01
Many of the earliest structural changes associated with neoplasia occur on the micro and nanometer scale, and thus appear histologically normal. Our group has established Inverse Spectroscopic OCT (ISOCT), a spectral based technique to extract nanoscale sensitive metrics derived from the OCT signal. Thus, there is a need to model light transport through relatively large volumes (< 50 um^3) of media with nanoscale level resolution. Finite Difference Time Domain (FDTD) is an iterative approach which directly solves Maxwell's equations to robustly estimate the electric and magnetic fields propagating through a sample. The sample's refractive index for every spatial voxel and wavelength are specified upon a grid with voxel sizes on the order of λ/20, making it an ideal modelling technique for nanoscale structure analysis. Here, we utilize the FDTD technique to validate the nanoscale sensing ability of ISOCT. The use of FDTD for OCT modelling requires three components: calculating the source beam as it propagates through the optical system, computing the sample's scattered field using FDTD, and finally propagating the scattered field back through the optical system. The principles of Fourier optics are employed to focus this interference field through a 4f optical system and onto the detector. Three-dimensional numerical samples are generated from a given refractive index correlation function with known parameters, and subsequent OCT images and mass density correlation function metrics are computed. We show that while the resolvability of the OCT image remains diffraction limited, spectral analysis allows nanoscale sensitive metrics to be extracted.
Validation of Statistical Sampling Algorithms in Visual Sample Plan (VSP): Summary Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nuffer, Lisa L; Sego, Landon H.; Wilson, John E.
2009-02-18
The U.S. Department of Homeland Security, Office of Technology Development (OTD) contracted with a set of U.S. Department of Energy national laboratories, including the Pacific Northwest National Laboratory (PNNL), to write a Remediation Guidance for Major Airports After a Chemical Attack. The report identifies key activities and issues that should be considered by a typical major airport following an incident involving release of a toxic chemical agent. Four experimental tasks were identified that would require further research in order to supplement the Remediation Guidance. One of the tasks, Task 4, OTD Chemical Remediation Statistical Sampling Design Validation, dealt with statisticalmore » sampling algorithm validation. This report documents the results of the sampling design validation conducted for Task 4. In 2005, the Government Accountability Office (GAO) performed a review of the past U.S. responses to Anthrax terrorist cases. Part of the motivation for this PNNL report was a major GAO finding that there was a lack of validated sampling strategies in the U.S. response to Anthrax cases. The report (GAO 2005) recommended that probability-based methods be used for sampling design in order to address confidence in the results, particularly when all sample results showed no remaining contamination. The GAO also expressed a desire that the methods be validated, which is the main purpose of this PNNL report. The objective of this study was to validate probability-based statistical sampling designs and the algorithms pertinent to within-building sampling that allow the user to prescribe or evaluate confidence levels of conclusions based on data collected as guided by the statistical sampling designs. Specifically, the designs found in the Visual Sample Plan (VSP) software were evaluated. VSP was used to calculate the number of samples and the sample location for a variety of sampling plans applied to an actual release site. Most of the sampling designs validated are probability based, meaning samples are located randomly (or on a randomly placed grid) so no bias enters into the placement of samples, and the number of samples is calculated such that IF the amount and spatial extent of contamination exceeds levels of concern, at least one of the samples would be taken from a contaminated area, at least X% of the time. Hence, "validation" of the statistical sampling algorithms is defined herein to mean ensuring that the "X%" (confidence) is actually met.« less
Shen, Minxue; Hu, Ming; Sun, Zhenqiu
2017-01-01
Objectives To develop and validate brief scales to measure common emotional and behavioural problems among adolescents in the examination-oriented education system and collectivistic culture of China. Setting Middle schools in Hunan province. Participants 5442 middle school students aged 11–19 years were sampled. 4727 valid questionnaires were collected and used for validation of the scales. The final sample included 2408 boys and 2319 girls. Primary and secondary outcome measures The tools were assessed by the item response theory, classical test theory (reliability and construct validity) and differential item functioning. Results Four scales to measure anxiety, depression, study problem and sociality problem were established. Exploratory factor analysis showed that each scale had two solutions. Confirmatory factor analysis showed acceptable to good model fit for each scale. Internal consistency and test–retest reliability of all scales were above 0.7. Item response theory showed that all items had acceptable discrimination parameters and most items had appropriate difficulty parameters. 10 items demonstrated differential item functioning with respect to gender. Conclusions Four brief scales were developed and validated among adolescents in middle schools of China. The scales have good psychometric properties with minor differential item functioning. They can be used in middle school settings, and will help school officials to assess the students’ emotional/behavioural problems. PMID:28062469
[Selection of risk and diagnosis in diabetic polyneuropathy. Validation of method of new systems].
Jurado, Jerónimo; Caula, Jacinto; Pou i Torelló, Josep Maria
2006-06-30
In a previous study we developed a specific algorithm, the polyneuropathy selection method (PSM) with 4 parameters (age, HDL-C, HbA1c, and retinopathy), to select patients at risk of diabetic polyneuropathy (DPN). We also developed a simplified method for DPN diagnosis: outpatient polyneuropathy diagnosis (OPD), with 4 variables (symptoms and 3 objective tests). To confirm the validity of conventional tests for DPN diagnosis; to validate the discriminatory power of the PSM and the diagnostic value of OPD by evaluating their relationship to electrodiagnosis studies and objective clinical neurological assessment; and to evaluate the correlation of DPN and pro-inflammatory status. Cross-sectional, crossed association for PSM validation. Paired samples for OPD validation. Primary care in 3 counties. Random sample of 75 subjects from the type-2 diabetes census for PSM evaluation. Thirty DPN patients and 30 non-DPN patients (from 2 DM2 sub-groups in our earlier study) for OPD evaluation. The gold standard for DPN diagnosis will be studied by means of a clinical neurological study (symptoms, physical examination, and sensitivity tests) and electrodiagnosis studies (sensitivity and motor EMG). Risks of neuropathy, macroangiopathy and pro-inflammatory status (PCR, TNF soluble fraction and total TGF-beta1) will be studied in every subject. Electrodiagnosis studies should confirm the validity of conventional tests for DPN diagnosis. PSM and OPD will be valid methods for selecting patients at risk and diagnosing DPN. There will be a significant relationship between DPN and pro-inflammatory tests.
Are atmospheric surface layer flows ergodic?
NASA Astrophysics Data System (ADS)
Higgins, Chad W.; Katul, Gabriel G.; Froidevaux, Martin; Simeonov, Valentin; Parlange, Marc B.
2013-06-01
The transposition of atmospheric turbulence statistics from the time domain, as conventionally sampled in field experiments, is explained by the so-called ergodic hypothesis. In micrometeorology, this hypothesis assumes that the time average of a measured flow variable represents an ensemble of independent realizations from similar meteorological states and boundary conditions. That is, the averaging duration must be sufficiently long to include a large number of independent realizations of the sampled flow variable so as to represent the ensemble. While the validity of the ergodic hypothesis for turbulence has been confirmed in laboratory experiments, and numerical simulations for idealized conditions, evidence for its validity in the atmospheric surface layer (ASL), especially for nonideal conditions, continues to defy experimental efforts. There is some urgency to make progress on this problem given the proliferation of tall tower scalar concentration networks aimed at constraining climate models yet are impacted by nonideal conditions at the land surface. Recent advancements in water vapor concentration lidar measurements that simultaneously sample spatial and temporal series in the ASL are used to investigate the validity of the ergodic hypothesis for the first time. It is shown that ergodicity is valid in a strict sense above uniform surfaces away from abrupt surface transitions. Surprisingly, ergodicity may be used to infer the ensemble concentration statistics of a composite grass-lake system using only water vapor concentration measurements collected above the sharp transition delineating the lake from the grass surface.
Identification of novel recurrent ETV6-IGH fusions in primary central nervous system lymphoma.
Bruno, Aurélie; Labreche, Karim; Daniau, Maïlys; Boisselier, Blandine; Gauchotte, Guillaume; Royer-Perron, Louis; Rahimian, Amithys; Lemoine, Frédéric; de la Grange, Pierre; Guégan, Justine; Bielle, Franck; Polivka, Marc; Adam, Clovis; Meyronet, David; Figarella-Branger, Dominique; Villa, Chiara; Chrétien, Fabrice; Eimer, Sandrine; Davi, Frédéric; Rousseau, Audrey; Houillier, Caroline; Soussain, Carole; Mokhtari, Karima; Hoang-Xuan, Khê; Alentorn, Agusti
2018-02-08
Primary central nervous system lymphoma (PCNSL) represents a particular entity within non-Hodgkin lymphomas and is associated with poor outcome. The present study addresses the potential clinical relevance of chimeric transcripts in PCSNL discovered by using RNA-sequencing (RNA-Seq). Seventy-two immunocompetent and newly diagnosed PCNSL cases were included in the present study. Among them, six were analyzed by RNA-seq to detect new potential fusion transcripts. We confirmed the results in the remaining 66 PCNSL. The gene fusion was validated by fluorescence in situ hybridization (FISH) using formalin-fixed paraffin-embedded (FFPE) samples. We assessed the biological and clinical impact of one new gene fusion. We identified a novel recurrent gene fusion ETV6-IgH. Overall, ETV6-IgH was found in 13 out of 72 PCNSL (18%). No fusion conserved an intact functional domain of ETV6 and ETV6 was significantly underexpressed at gene level, suggesting an ETV6 haploinsufficiency mechanism. The presence of the gene fusion was also validated by FISH in FFPE samples. Finally, PCNSL samples harboring ETV6-IgH showed a better prognosis in multivariate analysis, p-value=0.03, HR=0.33, 95% interval confidence (IC95) [0.12-0.88]. The overall survival at 5 years was of 69% for PCNSL harboring ETV6-IgH vs 29% for samples without this gene fusion. ETV6-IgH is a new potential surrogate marker of PCNSL with favorable prognosis with ETV6 haploinsuffiency as a possible mechanism. The potential clinical impact of ETV6-IgH should be validated in larger prospective studies. © The Author(s) 2018. Published by Oxford University Press on behalf of the Society for Neuro-Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Salvetti, David J.; Pino, Christopher J.; Manuel, Steven G.; Dallmeyer, Ian; Rangarajan, Sanjeet V.; Meyer, Tobias; Kotov, Misha
2012-01-01
Mechanical stimulation has been shown to impact the properties of engineered hyaline cartilage constructs and is relevant for engineering of cartilage and osteochondral tissues. Most mechanical stimulators developed to date emphasize precision over adaptability to standard tissue culture equipment and protocols. The realization of mechanical characteristics in engineered constructs approaching native cartilage requires the optimization of complex variables (type of stimulus, regimen, and bimolecular signals). We have proposed and validated a stimulator design that focuses on high construct capacity, compatibility with tissue culture plastic ware, and regimen adaptability to maximize throughput. This design utilizes thin force sensors in lieu of a load cell and a linear encoder to verify position. The implementation of an individual force sensor for each sample enables the measurement of Young's modulus while stimulating the sample. Removable and interchangeable Teflon plungers mounted using neodymium magnets contact each sample. Variations in plunger height and design can vary the strain and force type on individual samples. This allows for the evaluation of a myriad of culture conditions and regimens simultaneously. The system was validated using contact accuracy, and Young's modulus measurements range as key parameters. Contact accuracy for the system was excellent within 1.16% error of the construct height in comparison to measurements made with a micrometer. Biomaterials ranging from bioceramics (cancellous bone, 123 MPa) to soft gels (1% agarose, 20 KPa) can be measured without any modification to the device. The accuracy of measurements in conjunction with the wide range of moduli tested demonstrate the unique characteristics of the device and the feasibility of using this device in mapping real-time changes to Young's modulus of tissue constructs (cartilage, bone) through the developmental phases in ex vivo culture conditions. PMID:21988089
Testing of a Microfluidic Sampling System for High Temperature Electrochemical MC&A
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pereira, Candido; Nichols, Kevin
2013-11-27
This report describes the preliminary validation of a high-temperature microfluidic chip system for sampling of electrochemical process salt. Electroanalytical and spectroscopic techniques are attractive candidates for improvement through high-throughput sample analysis via miniaturization. Further, microfluidic chip systems are amenable to micro-scale chemical processing such as rapid, automated sample purification to improve sensor performance. The microfluidic chip was tested to determine the feasibility of the system for high temperature applications and conditions under which microfluidic systems can be used to generate salt droplets at process temperature to support development of material balance and control systems in a used fuel treatment facility.more » In FY13, the project focused on testing a quartz microchip device with molten salts at near process temperatures. The equipment was installed in glove box and tested up to 400°C using commercial thermal transfer fluids as the carrier phase. Preliminary tests were carried out with a low-melting halide salt to initially characterize the properties of this novel liquid-liquid system and to investigate the operating regimes for inducing droplet flow within candidate carrier fluids. Initial results show that the concept is viable for high temperature sampling but further development is required to optimize the system to operate with process relevant molten salts.« less
Atmospheric Observations from Unmanned Aircraft Systems
NASA Technical Reports Server (NTRS)
Newman, Paul A.
2008-01-01
Unmanned Aircraft Systems (UASs) provide a new and exciting avenue for atmospheric observations. NASA has a number of UASs. Amongst these are the Ikhana (24 hrs., 7000 km), the Altair (120 hrs., 6500 km), the Aerosonde (30 hrs., 3000 km), and the Global Hawk (30 hrs., 22,000 km). This presentation provides a brief history of UASs which is followed by a description of their capabilities. The presentation concludes by describing an example mission - the UAS Aura Validation Experiment (UAS-AVE). This mission will be flown on the NASA Global Hawk in the Spring/Summer of 2009. The goals fo the mission are to: 1) provide Aura validation observations, 2) sample the break up of the Arctic polar vortex, 3) observed cross-Pacific transport of aerosols and pollutants such as ozone, and 4) sample intense water advective events that impact the U.S. west coast (atmospheric rivers). Because of their range and duration, UASs provide new and exciting opportunities for atmospheric science.
NASA Astrophysics Data System (ADS)
Rufino, Marta M.; Baptista, Paulo; Pereira, Fábio; Gaspar, Miguel B.
2018-01-01
In the current work we propose a new method to sample surface sediment during bivalve fishing surveys. Fishing institutes all around the word carry out regular surveys with the aim of monitoring the stocks of commercial species. These surveys comprise often more than one hundred of sampling stations and cover large geographical areas. Although superficial sediment grain sizes are among the main drivers of benthic communities and provide crucial information for studies on coastal dynamics, overall there is a strong lack of this type of data, possibly, because traditional surface sediment sampling methods use grabs, that require considerable time and effort to be carried out on regular basis or on large areas. In face of these aspects, we developed an easy and un-expensive method to sample superficial sediments, during bivalve fisheries monitoring surveys, without increasing survey time or human resources. The method was successfully evaluated and validated during a typical bivalve survey carried out on the Northwest coast of Portugal, confirming that it had any interference with the survey objectives. Furthermore, the method was validated by collecting samples using a traditional Van Veen grabs (traditional method), which showed a similar grain size composition to the ones collected by the new method, on the same localities. We recommend that the procedure is implemented on regular bivalve fishing surveys, together with an image analysis system to analyse the collected samples. The new method will provide substantial quantity of data on surface sediment in coastal areas, using a non-expensive and efficient manner, with a high potential application in different fields of research.
NASA Astrophysics Data System (ADS)
Bilan, Regina; Ametzazurra, Amagoia; Brazhnik, Kristina; Escorza, Sergio; Fernández, David; Uríbarri, María; Nabiev, Igor; Sukhanova, Alyona
2017-03-01
A novel suspension multiplex immunoassay for the simultaneous specific detection of lung cancer markers in bronchoalveolar lavage fluid (BALF) clinical samples based on fluorescent microspheres having different size and spectrally encoded with quantum dots (QDEM) was developed. The designed suspension immunoassay was validated for the quantitative detection of three lung cancer markers in BALF samples from 42 lung cancer patients and 10 control subjects. Tumor markers were detected through simultaneous formation of specific immune complexes consisting of a capture molecule, the target antigen, and biotinylated recognition molecule on the surface of the different QDEM in a mixture. The immune complexes were visualized by fluorescently labeled streptavidin and simultaneously analyzed using a flow cytometer. Preclinical validation of the immunoassay was performed and results were compared with those obtained using an alternative 3-plex immunoassay based on Luminex xMAP® technology, developed on classical organic fluorophores. The comparison showed that the QDEM and xMAP® assays yielded almost identical results, with clear discrimination between control and clinical samples. Thus, developed QDEM technology can become a good alternative to xMAP® assays permitting analysis of multiple protein biomarkers using conventional flow cytometers.
Bilan, Regina; Ametzazurra, Amagoia; Brazhnik, Kristina; Escorza, Sergio; Fernández, David; Uríbarri, María; Nabiev, Igor; Sukhanova, Alyona
2017-01-01
A novel suspension multiplex immunoassay for the simultaneous specific detection of lung cancer markers in bronchoalveolar lavage fluid (BALF) clinical samples based on fluorescent microspheres having different size and spectrally encoded with quantum dots (QDEM) was developed. The designed suspension immunoassay was validated for the quantitative detection of three lung cancer markers in BALF samples from 42 lung cancer patients and 10 control subjects. Tumor markers were detected through simultaneous formation of specific immune complexes consisting of a capture molecule, the target antigen, and biotinylated recognition molecule on the surface of the different QDEM in a mixture. The immune complexes were visualized by fluorescently labeled streptavidin and simultaneously analyzed using a flow cytometer. Preclinical validation of the immunoassay was performed and results were compared with those obtained using an alternative 3-plex immunoassay based on Luminex xMAP® technology, developed on classical organic fluorophores. The comparison showed that the QDEM and xMAP® assays yielded almost identical results, with clear discrimination between control and clinical samples. Thus, developed QDEM technology can become a good alternative to xMAP® assays permitting analysis of multiple protein biomarkers using conventional flow cytometers. PMID:28300171
Decision support for clinical laboratory capacity planning.
van Merode, G G; Hasman, A; Derks, J; Goldschmidt, H M; Schoenmaker, B; Oosten, M
1995-01-01
The design of a decision support system for capacity planning in clinical laboratories is discussed. The DSS supports decisions concerning the following questions: how should the laboratory be divided into job shops (departments/sections), how should staff be assigned to workstations and how should samples be assigned to workstations for testing. The decision support system contains modules for supporting decisions at the overall laboratory level (concerning the division of the laboratory into job shops) and for supporting decisions at the job shop level (assignment of staff to workstations and sample scheduling). Experiments with these modules are described showing both the functionality and the validity.
Southern Africa Validation of NASA's Earth Observing System (SAVE EOS)
NASA Technical Reports Server (NTRS)
Privette, Jeffrey L.
2000-01-01
Southern Africa Validation of EOS (SAVE) is 4-year, multidisciplinary effort to validate operational and experimental products from Terra-the flagship satellite of NASA's Earth Observing System (EOS). At test sites from Zambia to South Africa, we are measuring soil, vegetation and atmospheric parameters over a range of ecosystems for comparison with products from Terra, Landsat 7, AVHRR and SeaWiFS. The data are also employed to parameterize and improve vegetation process models. Fixed-point and mobile "transect" sampling are used to collect the ground data. These are extrapolated over larger areas with fine-resolution multispectral imagery. We describe the sites, infrastructure, and measurement strategies developed underSAVE, as well as initial results from our participation in the first Intensive Field Campaign of SAFARI 2000. We also describe SAVE's role in the Kalahari Transect Campaign (February/March 2000) in Zambia and Botswana.
Chen, Yang; Reddy, Ravinder M; Li, Wenjing; Yettlla, Ramesh R; Lopez, Salvador; Woodman, Michael
2015-01-01
An HPLC method for simultaneous determination of vitamins A and D3 in fluid milk was developed and validated. Saponification and extraction conditions were studied for optimum recovery and simplicity. An RP HPLC system equipped with a C18 column and diode array detector was used for quantitation. The method was subjected to a single-laboratory validation using skim, 2% fat, and whole milk samples at concentrations of 50, 100, and 200% of the recommended fortification levels for vitamins A and D3 for Grade "A" fluid milk. The method quantitation limits for vitamins A and D3 were 0.0072 and 0.0026 μg/mL, respectively. Average recoveries between 94 and 110% and SD values ranging from 2.7 to 6.9% were obtained for both vitamins A and D3. The accuracy of the method was evaluated using a National Institute of Standards and Technology standard reference material (1849a) and proficiency test samples.
Kim, Na Young; Lee, Hwan Young; Park, Sun Joo; Yang, Woo Ick; Shin, Kyoung-Jin
2013-05-01
Two multiplex polymerase chain reaction (PCR) systems (Midiplex and Miniplex) were developed for the amplification of the mitochondrial DNA (mtDNA) control region, and the efficiencies of the multiplexes for amplifying degraded DNA were validated using old skeletal remains. The Midiplex system consisted of two multiplex PCRs to amplify six overlapping amplicons ranging in length from 227 to 267 bp. The Miniplex system consisted of three multiplex PCRs to amplify 10 overlapping short amplicons ranging in length from 142 to 185 bp. Most mtDNA control region sequences of several 60-year-old and 400-500-year-old skeletal remains were successfully obtained using both PCR systems and consistent with those previously obtained by monoplex amplification. The multiplex system consisting of smaller amplicons is effective for mtDNA sequence analyses of ancient and forensic degraded samples, saving time, cost, and the amount of DNA sample consumed during analysis. © 2013 American Academy of Forensic Sciences.
40 CFR 1065.545 - Validation of proportional flow control for batch sampling.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Validation of proportional flow control for batch sampling. 1065.545 Section 1065.545 Protection of Environment ENVIRONMENTAL PROTECTION... Specified Duty Cycles § 1065.545 Validation of proportional flow control for batch sampling. For any...
40 CFR 1065.545 - Validation of proportional flow control for batch sampling.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Validation of proportional flow control for batch sampling. 1065.545 Section 1065.545 Protection of Environment ENVIRONMENTAL PROTECTION... Specified Duty Cycles § 1065.545 Validation of proportional flow control for batch sampling. For any...
40 CFR 1065.545 - Validation of proportional flow control for batch sampling.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Validation of proportional flow control for batch sampling. 1065.545 Section 1065.545 Protection of Environment ENVIRONMENTAL PROTECTION... Specified Duty Cycles § 1065.545 Validation of proportional flow control for batch sampling. For any...
Age determination of bottled Chinese rice wine by VIS-NIR spectroscopy
NASA Astrophysics Data System (ADS)
Yu, Haiyan; Lin, Tao; Ying, Yibin; Pan, Xingxiang
2006-10-01
The feasibility of non-invasive visible and near infrared (VIS-NIR) spectroscopy for determining wine age (1, 2, 3, 4, and 5 years) of Chinese rice wine was investigated. Samples of Chinese rice wine were analyzed in 600 mL square brown glass bottles with side length of approximately 64 mm at room temperature. VIS-NIR spectra of 100 bottled Chinese rice wine samples were collected in transmission mode in the wavelength range of 350-1200 nm by a fiber spectrometer system. Discriminant models were developed based on discriminant analysis (DA) together with raw, first and second derivative spectra. The concentration of alcoholic degree, total acid, and °Brix was determined to validate the NIR results. The calibration result for raw spectra was better than that for first and second derivative spectra. The percentage of samples correctly classified for raw spectra was 98%. For 1-, 2-, and 3-year-old sample groups, the sample were all correctly classified, and for 4- and 5-year-old sample groups, the percentage of samples correctly classified was 92.9%, respectively. In validation analysis, the percentage of samples correctly classified was 100%. The results demonstrated that VIS-NIR spectroscopic technique could be used as a non-invasive, rapid and reliable method for predicting wine age of bottled Chinese rice wine.
2017-09-01
information provided from the GED (Peggy Harris, personal communication ), but unprecedented high rainfall (including 20” of rain April 29–30, 2014...Alexandria, VA, by the Energy and Environmental Sustainability Branch (71760) of the Advanced Systems and Applied Sciences Division (71700), Space ...sampling and analyses. These challenges include a high level of effort or difficulty required to (1) measure MC at very low (ng/L) concentrations; (2
Post-Shock Sampling of Shock-Heated Hydrocarbon Fuels
2016-07-07
on the ability to measure key hydrocarbon fragments (e.g. ethylene , methane, and acetylene) over a wide range of temperatures and pressures. The...series of experiments was conducted to validate the sampling system results and explore the thermal decomposition of ethylene and methane. Initially, a...1% ethylene /0.1% methane/balance argon fuel mixture was shock-heated to ~960 K – a temperature low enough that no reaction would occur. GC analysis
Bock, Astrid; Huber, Eva; Peham, Doris; Benecke, Cord
2015-01-01
The development (Study 1) and validation (Study 2) of a categorical system for the attribution of facial expressions of negative emotions to specific functions. The facial expressions observed inOPDinterviews (OPD-Task-Force 2009) are coded according to the Facial Action Coding System (FACS; Ekman et al. 2002) and attributed to categories of basic emotional displays using EmFACS (Friesen & Ekman 1984). In Study 1 we analyze a partial sample of 20 interviews and postulate 10 categories of functions that can be arranged into three main categories (interactive, self and object). In Study 2 we rate the facial expressions (n=2320) from the OPD interviews (10 minutes each interview) of 80 female subjects (16 healthy, 64 with DSM-IV diagnosis; age: 18-57 years) according to the categorical system and correlate them with problematic relationship experiences (measured with IIP,Horowitz et al. 2000). Functions of negative facial expressions can be attributed reliably and validly with the RFE-Coding System. The attribution of interactive, self-related and object-related functions allows for a deeper understanding of the emotional facial expressions of patients with mental disorders.
A self-report measure of legal and administrative aggression within intimate relationships.
Hines, Denise A; Douglas, Emily M; Berger, Joshua L
2015-01-01
Although experts agree that intimate partner violence (IPV) is a multidimensional phenomenon comprised of both physical and non-physical acts, there is no measure of legal and administrative (LA) forms of IPV. LA aggression is when one partner manipulates the legal and other administrative systems to the detriment of his/her partner. Our measure was developed using the qualitative literature on male IPV victims' experiences. We tested the reliability and validity of our LA aggression measure on two samples of men: 611 men who sustained IPV and sought help, and 1,601 men in a population-based sample. Construct validity of the victimization scale was supported through factor analyses, correlations with other forms of IPV victimization, and comparisons of the rates of LA aggression between the two samples; reliability was established through Cronbach's alpha. Evidence for the validity and reliability of the perpetration scale was mixed and therefore needs further analyses and revisions before we can recommend its use in empirical work. There is initial support for the victimization scale as a valid and reliable measure of LA aggression victimization among men, but work is needed using women's victimization's experiences to establish reliability and validity of this measure for women. An LA aggression measure should be developed using LGBTQ victims' experiences, and for couples who are well into the divorce and child custody legal process. Legal personnel and practitioners should be educated on this form of IPV so that they can appropriately work with clients who have been victimized or perpetrate LA aggression. © 2014 Wiley Periodicals, Inc.
Li, Polly W C; Yu, Doris S F
Atypical symptom presentation in patients with acute myocardial infarction (AMI) is associated with longer delay in care seeking and poorer prognosis. Symptom recognition in these patients is a challenging task. Our purpose in this risk prediction model development study was to develop and validate a risk scoring system for estimating cumulative risk for atypical AMI presentation. A consecutive sample was recruited for the developmental (n = 300) and validation (n = 97) cohorts. Symptom experience was measured with the validated Chinese version of the Symptoms of Acute Coronary Syndromes Inventory. Potential predictors were identified from the literature. Multivariable logistic regression was performed to identify significant predictors. A risk scoring system was then constructed by assigning weights to each significant predictor according to their b coefficients. Five independent predictors for atypical symptom presentation were older age (≥75 years), female gender, diabetes mellitus, history of AMI, and absence of hyperlipidemia. The Hosmer and Lemeshow test (χ6 = 4.47, P = .62) indicated that this predictive model was adequate to predict the outcome. Acceptable discrimination was demonstrated, with area under the receiver operating characteristic curve as 0.74 (95% confidence interval, 0.67-0.82) (P < .001). The predictive power of this risk scoring system was confirmed in the validation cohort. Atypical AMI presentation is common. A simple risk scoring system developed on the basis of the 5 identified predictors can raise awareness of atypical AMI presentation and promote symptom recognition by estimating the cumulative risk for an individual to present with atypical AMI symptoms.
Construct validity of the PROMIS® sexual function and satisfaction measures in patients with cancer
2013-01-01
Background With data from a diverse sample of patients either in treatment for cancer or post-treatment for cancer, we examine inter-domain and cross-domain correlations among the core domains of the Patient-Reported Outcomes Measurement Information System Sexual Function and Satisfaction measures (PROMIS® SexFS) and the corresponding domains from conceptually-similar measures of sexual function, the International Index of Erectile Function and the Female Sexual Function Index. Findings Men (N=389) and women (N=430) were recruited from a tumor registry, oncology clinics, and an internet panel. The PROMIS SexFS, International Index of Erectile Function, and Female Sexual Function Index were used to collect participants’ self-reported sexual function. The domains shared among the measures include desire/interest in sexual activity, lubrication and vaginal discomfort/pain (women), erectile function (men), orgasm, and satisfaction. We examined correlations among different domains within the same instrument (discriminant validity) and correlations among similar domains measured by different instruments (convergent validity). Correlations demonstrating discriminant validity ranged from 0.38 to 0.73 for men and 0.48 to 0.74 for women, while correlations demonstrating convergent validity ranged from 0.62 to 0.83 for men and 0.71 to 0.92 for women. As expected, correlations demonstrating convergent validity were higher than correlations demonstrating discriminant validity, with one exception (orgasm for men). Conclusions Construct validity was supported by convergent and discriminant validity in a diverse sample of patients with cancer. For patients with cancer who may or may not have sexual dysfunction, the PROMIS SexFS measures provide a comprehensive assessment of key domains of sexual function and satisfaction. PMID:23497200
Pérez-Del-Olmo, A; Montero, F E; Fernández, M; Barrett, J; Raga, J A; Kostadinova, A
2010-10-01
We address the effect of spatial scale and temporal variation on model generality when forming predictive models for fish assignment using a new data mining approach, Random Forests (RF), to variable biological markers (parasite community data). Models were implemented for a fish host-parasite system sampled along the Mediterranean and Atlantic coasts of Spain and were validated using independent datasets. We considered 2 basic classification problems in evaluating the importance of variations in parasite infracommunities for assignment of individual fish to their populations of origin: multiclass (2-5 population models, using 2 seasonal replicates from each of the populations) and 2-class task (using 4 seasonal replicates from 1 Atlantic and 1 Mediterranean population each). The main results are that (i) RF are well suited for multiclass population assignment using parasite communities in non-migratory fish; (ii) RF provide an efficient means for model cross-validation on the baseline data and this allows sample size limitations in parasite tag studies to be tackled effectively; (iii) the performance of RF is dependent on the complexity and spatial extent/configuration of the problem; and (iv) the development of predictive models is strongly influenced by seasonal change and this stresses the importance of both temporal replication and model validation in parasite tagging studies.
In Situ Miniaturised Solid Phase Extraction (m-SPE) for Organic Pollutants in Seawater Samples
Abaroa-Pérez, B.; Sánchez-Almeida, G.; Hernández-Brito, J. J.
2018-01-01
Solid phase extraction (SPE) is a consolidated technique for determining pollutants in seawater samples. The current tendency is to miniaturise systems that extract and determine pollutants in the environment, reducing the use of organic solvents, while maintaining the quality in the extraction and preconcentration. On the other hand, there is a need to develop new extraction systems that can be fitted to in situ continual monitoring buoys, especially for the marine environment. This work has developed a first model of a low-pressure micro-SPE (m-SPE) for persistent organic pollutants (POPs) that can be simply applied to in situ monitoring in the marine environment. This system reduces the volumes of sample and solvents required in the laboratory in comparison with conventional SPE. In the future, it could be used in automated or robotic systems in marine technologies such as marine gliders and oceanographic buoys. This system has been optimised and validated to determine polycyclic aromatic hydrocarbons (PAH) in seawater samples, but it could also be applied to other kinds of persistent organic pollutants (POPs) and emerging pollutants. PMID:29805837
Validation of a Prototype Optical Computed Tomography System
Zakariaee, Seyed Salman; Molazadeh, Mikaeil; Takavar, Abbas; Shirazi, Alireza; Mesbahi, Asghar; Zeinali, Ahad
2015-01-01
In radiation cancer treatments, the most of the side effects could be minimized using a proper dosimeter. Gel dosimeter is the only three-dimensional dosimeter and magnetic resonance imaging (MRI) is the gold standard method for gel dosimeter readout. Because of hard accessibility and high cost of sample reading by MRI systems, some other alternative methods were developed. The optical computed tomography (OCT) method could be considered as the most promising alternative method that has been studied widely. In the current study, gel dosimeter scanning using a prototype optical scanner and validation of this optical scanner was performed. Optical absorbance of the irradiated gel samples was determined by both of conventional spectrophotometer and the fabricated OCT system at 632 nm. Furthermore, these irradiated vials were scanned by a 1.5 T MRI. The slope of the curves was extracted as the dose-response sensitivity. The R2-dose sensitivity measured by MRI method was 0.1904 and 0.113 for NIPAM and PAGAT gels, respectively. The optical dose sensitivity obtained by conventional spectrophotometer and the fabricated optical scanner was 0.0453 and 0.0442 for NIPAM gels and 0.0244 and 0.0242 for PAGAT gels, respectively. The scanning results of the absorbed dose values showed that the new OCT and conventional spectrophotometer were in fair agreement. From the results, it could be concluded that the fabricated system is able to quantize the absorbed dose values in polymer gel samples with acceptable accuracy. PMID:26120572
NASA Astrophysics Data System (ADS)
Fisher, B. L.; Wolff, D. B.; Silberstein, D. S.; Marks, D. M.; Pippitt, J. L.
2007-12-01
The Tropical Rainfall Measuring Mission's (TRMM) Ground Validation (GV) Program was originally established with the principal long-term goal of determining the random errors and systematic biases stemming from the application of the TRMM rainfall algorithms. The GV Program has been structured around two validation strategies: 1) determining the quantitative accuracy of the integrated monthly rainfall products at GV regional sites over large areas of about 500 km2 using integrated ground measurements and 2) evaluating the instantaneous satellite and GV rain rate statistics at spatio-temporal scales compatible with the satellite sensor resolution (Simpson et al. 1988, Thiele 1988). The GV Program has continued to evolve since the launch of the TRMM satellite on November 27, 1997. This presentation will discuss current GV methods of validating TRMM operational rain products in conjunction with ongoing research. The challenge facing TRMM GV has been how to best utilize rain information from the GV system to infer the random and systematic error characteristics of the satellite rain estimates. A fundamental problem of validating space-borne rain estimates is that the true mean areal rainfall is an ideal, scale-dependent parameter that cannot be directly measured. Empirical validation uses ground-based rain estimates to determine the error characteristics of the satellite-inferred rain estimates, but ground estimates also incur measurement errors and contribute to the error covariance. Furthermore, sampling errors, associated with the discrete, discontinuous temporal sampling by the rain sensors aboard the TRMM satellite, become statistically entangled in the monthly estimates. Sampling errors complicate the task of linking biases in the rain retrievals to the physics of the satellite algorithms. The TRMM Satellite Validation Office (TSVO) has made key progress towards effective satellite validation. For disentangling the sampling and retrieval errors, TSVO has developed and applied a methodology that statistically separates the two error sources. Using TRMM monthly estimates and high-resolution radar and gauge data, this method has been used to estimate sampling and retrieval error budgets over GV sites. More recently, a multi- year data set of instantaneous rain rates from the TRMM microwave imager (TMI), the precipitation radar (PR), and the combined algorithm was spatio-temporally matched and inter-compared to GV radar rain rates collected during satellite overpasses of select GV sites at the scale of the TMI footprint. The analysis provided a more direct probe of the satellite rain algorithms using ground data as an empirical reference. TSVO has also made significant advances in radar quality control through the development of the Relative Calibration Adjustment (RCA) technique. The RCA is currently being used to provide a long-term record of radar calibration for the radar at Kwajalein, a strategically important GV site in the tropical Pacific. The RCA technique has revealed previously undetected alterations in the radar sensitivity due to engineering changes (e.g., system modifications, antenna offsets, alterations of the receiver, or the data processor), making possible the correction of the radar rainfall measurements and ensuring the integrity of nearly a decade of TRMM GV observations and resources.
Method for Pre-Conditioning a Measured Surface Height Map for Model Validation
NASA Technical Reports Server (NTRS)
Sidick, Erkin
2012-01-01
This software allows one to up-sample or down-sample a measured surface map for model validation, not only without introducing any re-sampling errors, but also eliminating the existing measurement noise and measurement errors. Because the re-sampling of a surface map is accomplished based on the analytical expressions of Zernike-polynomials and a power spectral density model, such re-sampling does not introduce any aliasing and interpolation errors as is done by the conventional interpolation and FFT-based (fast-Fourier-transform-based) spatial-filtering method. Also, this new method automatically eliminates the measurement noise and other measurement errors such as artificial discontinuity. The developmental cycle of an optical system, such as a space telescope, includes, but is not limited to, the following two steps: (1) deriving requirements or specs on the optical quality of individual optics before they are fabricated through optical modeling and simulations, and (2) validating the optical model using the measured surface height maps after all optics are fabricated. There are a number of computational issues related to model validation, one of which is the "pre-conditioning" or pre-processing of the measured surface maps before using them in a model validation software tool. This software addresses the following issues: (1) up- or down-sampling a measured surface map to match it with the gridded data format of a model validation tool, and (2) eliminating the surface measurement noise or measurement errors such that the resulted surface height map is continuous or smoothly-varying. So far, the preferred method used for re-sampling a surface map is two-dimensional interpolation. The main problem of this method is that the same pixel can take different values when the method of interpolation is changed among the different methods such as the "nearest," "linear," "cubic," and "spline" fitting in Matlab. The conventional, FFT-based spatial filtering method used to eliminate the surface measurement noise or measurement errors can also suffer from aliasing effects. During re-sampling of a surface map, this software preserves the low spatial-frequency characteristic of a given surface map through the use of Zernike-polynomial fit coefficients, and maintains mid- and high-spatial-frequency characteristics of the given surface map by the use of a PSD model derived from the two-dimensional PSD data of the mid- and high-spatial-frequency components of the original surface map. Because this new method creates the new surface map in the desired sampling format from analytical expressions only, it does not encounter any aliasing effects and does not cause any discontinuity in the resultant surface map.
Flexible automated approach for quantitative liquid handling of complex biological samples.
Palandra, Joe; Weller, David; Hudson, Gary; Li, Jeff; Osgood, Sarah; Hudson, Emily; Zhong, Min; Buchholz, Lisa; Cohen, Lucinda H
2007-11-01
A fully automated protein precipitation technique for biological sample preparation has been developed for the quantitation of drugs in various biological matrixes. All liquid handling during sample preparation was automated using a Hamilton MicroLab Star Robotic workstation, which included the preparation of standards and controls from a Watson laboratory information management system generated work list, shaking of 96-well plates, and vacuum application. Processing time is less than 30 s per sample or approximately 45 min per 96-well plate, which is then immediately ready for injection onto an LC-MS/MS system. An overview of the process workflow is discussed, including the software development. Validation data are also provided, including specific liquid class data as well as comparative data of automated vs manual preparation using both quality controls and actual sample data. The efficiencies gained from this automated approach are described.
Communication: Multiple atomistic force fields in a single enhanced sampling simulation
NASA Astrophysics Data System (ADS)
Hoang Viet, Man; Derreumaux, Philippe; Nguyen, Phuong H.
2015-07-01
The main concerns of biomolecular dynamics simulations are the convergence of the conformational sampling and the dependence of the results on the force fields. While the first issue can be addressed by employing enhanced sampling techniques such as simulated tempering or replica exchange molecular dynamics, repeating these simulations with different force fields is very time consuming. Here, we propose an automatic method that includes different force fields into a single advanced sampling simulation. Conformational sampling using three all-atom force fields is enhanced by simulated tempering and by formulating the weight parameters of the simulated tempering method in terms of the energy fluctuations, the system is able to perform random walk in both temperature and force field spaces. The method is first demonstrated on a 1D system and then validated by the folding of the 10-residue chignolin peptide in explicit water.
van der Kooy, Jacoba; Valentine, Nicole B; Birnie, Erwin; Vujkovic, Marijana; de Graaf, Johanna P; Denktaş, Semiha; Steegers, Eric A P; Bonsel, Gouke J
2014-12-03
The concept of responsiveness, introduced by the World Health Organization (WHO), addresses non-clinical aspects of health service quality that are relevant regardless of provider, country, health system or health condition. Responsiveness refers to "aspects related to the way individuals are treated and the environment in which they are treated" during health system interactions. This paper assesses the psychometric properties of a newly developed responsiveness questionnaire dedicated to evaluating maternal experiences of perinatal care services, called the Responsiveness in Perinatal and Obstetric Health Care Questionnaire (ReproQ), using the eight-domain WHO concept. The ReproQ was developed between October 2009 and February 2010 by adapting the WHO Responsiveness Questionnaire items to the perinatal care context. The psychometric properties of feasibility, construct validity, and discriminative validity were empirically assessed in a sample of Dutch women two weeks post partum. A total of 171 women consented to participation. Feasibility: the interviews lasted between 20 and 40 minutes and the overall missing rate was 8%. Construct validity: mean Cronbach's alphas for the antenatal, birth and postpartum phase were: 0.73 (range 0.57-0.82), 0.84 (range 0.66-0.92), and 0.87 (range 0.62-0.95) respectively. The item-own scale correlations within all phases were considerably higher than most of the item-other scale correlations. Within the antenatal care, birth care and post partum phases, the eight factors explained 69%, 69%, and 76% of variance respectively. Discriminative validity: overall responsiveness mean sum scores were higher for women whose children were not admitted. This confirmed the hypothesis that dissatisfaction with health outcomes is transferred to their judgement on responsiveness of the perinatal services. The ReproQ interview-based questionnaire demonstrated satisfactory psychometric properties to describe the quality of perinatal care in the Netherlands, with the potential to discriminate between different levels of quality of care. In view of the relatively small sample, further testing and research is recommended.
Rhea, Jeanne M; French, Deborah; Molinaro, Ross J
2013-05-01
To develop and validate liquid chromatography tandem mass spectrometry (LC-MS/MS) methods for the direct measurement of total and free testosterone in patient samples on two different analytical systems. An API 4000 and 5000 triple quadropoles were used and compared; the former is reported to be 3-5 times less sensitive, as was used to set the quantitation limits. Free testosterone was separated from the protein-bound fraction by equilibrium dialysis followed by derivatization. Either free or total testosterone, and a deuterated internal standard (d3-testosterone) were extracted by liquid-liquid extraction. The validation results were compared to two different clinical laboratories. The use of d2-testosterone was found to be unacceptable for our method. The total testosterone LC-MS/MS methods on both systems were linear over a wide concentration range of 1.5-2000ng/dL. Free testosterone was measured directly using equilibrium dialysis coupled LC-MS/MS and linear over the concentration range of 2.5-2500pg/mL. Good correlation (total testosterone, R(2)=0.96; free testosterone, R(2)=0.98) was observed between our LC-MS/MS systems and comparator laboratory. However, differences in absolute values for both free and total testosterone measurements were observed while a comparison to a second published LC-MS/MS method showed excellent correlation. Free and total testosterone measurements correlated well with clinical observations. To our knowledge, this is the first published validation of free and total testosterone methods across two analytical systems of different analytical sensitivities. A less sensitive system does not sacrifice analytical or clinical sensitivity to directly measure free and total testosterone in patient samples. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
New family of biosensors for monitoring BTX in aquatic and edaphic environments.
Hernández-Sánchez, Verónica; Molina, Lázaro; Ramos, Juan Luis; Segura, Ana
2016-11-01
Benzene, toluene, ethylbenzene and xylenes (BTEX) contamination is a serious threat to public health and the environment, and therefore, there is an urgent need to detect its presence in nature. The use of whole-cell reporters is an efficient, easy-to-use and low-cost approach to detect and follow contaminants outside specialized laboratories; this is especially important in oil spills that are frequent in marine environments. The aim of this study is the construction of a bioreporter system and its comparison and validation for the specific detection of monocyclic aromatic hydrocarbons in different host bacteria and environmental samples. Our bioreporter system is based on the two component regulatory system TodS-TodT of P. putida DOT-T1E, and the P todX promoter fused to the GFP protein as the reporter protein. For the construction of different biosensors, this bioreporter was transferred into three different bacterial strains isolated from three different environments, and their performance was measured. Validation of the biosensors on water samples spiked with petrol, diesel and crude oil on contaminated waters from oil spills and on contaminated soils demonstrated that they can be used in mapping and monitoring some BTEX compounds (specifically benzene, toluene and two xylene isomers). Validation of biosensors is an important issue for the integration of these devices into pollution-control programmes. © 2016 The Authors. Microbial Biotechnology published by John Wiley & Sons Ltd and Society for Applied Microbiology.
Lynch, Tim P; Morello, Elisabetta B; Evans, Karen; Richardson, Anthony J; Rochester, Wayne; Steinberg, Craig R; Roughan, Moninya; Thompson, Peter; Middleton, John F; Feng, Ming; Sherrington, Robert; Brando, Vittorio; Tilbrook, Bronte; Ridgway, Ken; Allen, Simon; Doherty, Peter; Hill, Katherine; Moltmann, Tim C
2014-01-01
Sustained observations allow for the tracking of change in oceanography and ecosystems, however, these are rare, particularly for the Southern Hemisphere. To address this in part, the Australian Integrated Marine Observing System (IMOS) implemented a network of nine National Reference Stations (NRS). The network builds on one long-term location, where monthly water sampling has been sustained since the 1940s and two others that commenced in the 1950s. In-situ continuously moored sensors and an enhanced monthly water sampling regime now collect more than 50 data streams. Building on sampling for temperature, salinity and nutrients, the network now observes dissolved oxygen, carbon, turbidity, currents, chlorophyll a and both phytoplankton and zooplankton. Additional parameters for studies of ocean acidification and bio-optics are collected at a sub-set of sites and all data is made freely and publically available. Our preliminary results demonstrate increased utility to observe extreme events, such as marine heat waves and coastal flooding; rare events, such as plankton blooms; and have, for the first time, allowed for consistent continental scale sampling and analysis of coastal zooplankton and phytoplankton communities. Independent water sampling allows for cross validation of the deployed sensors for quality control of data that now continuously tracks daily, seasonal and annual variation. The NRS will provide multi-decadal time series, against which more spatially replicated short-term studies can be referenced, models and remote sensing products validated, and improvements made to our understanding of how large-scale, long-term change and variability in the global ocean are affecting Australia's coastal seas and ecosystems. The NRS network provides an example of how a continental scaled observing systems can be developed to collect observations that integrate across physics, chemistry and biology.
Lynch, Tim P.; Morello, Elisabetta B.; Evans, Karen; Richardson, Anthony J.; Rochester, Wayne; Steinberg, Craig R.; Roughan, Moninya; Thompson, Peter; Middleton, John F.; Feng, Ming; Sherrington, Robert; Brando, Vittorio; Tilbrook, Bronte; Ridgway, Ken; Allen, Simon; Doherty, Peter; Hill, Katherine; Moltmann, Tim C.
2014-01-01
Sustained observations allow for the tracking of change in oceanography and ecosystems, however, these are rare, particularly for the Southern Hemisphere. To address this in part, the Australian Integrated Marine Observing System (IMOS) implemented a network of nine National Reference Stations (NRS). The network builds on one long-term location, where monthly water sampling has been sustained since the 1940s and two others that commenced in the 1950s. In-situ continuously moored sensors and an enhanced monthly water sampling regime now collect more than 50 data streams. Building on sampling for temperature, salinity and nutrients, the network now observes dissolved oxygen, carbon, turbidity, currents, chlorophyll a and both phytoplankton and zooplankton. Additional parameters for studies of ocean acidification and bio-optics are collected at a sub-set of sites and all data is made freely and publically available. Our preliminary results demonstrate increased utility to observe extreme events, such as marine heat waves and coastal flooding; rare events, such as plankton blooms; and have, for the first time, allowed for consistent continental scale sampling and analysis of coastal zooplankton and phytoplankton communities. Independent water sampling allows for cross validation of the deployed sensors for quality control of data that now continuously tracks daily, seasonal and annual variation. The NRS will provide multi-decadal time series, against which more spatially replicated short-term studies can be referenced, models and remote sensing products validated, and improvements made to our understanding of how large-scale, long-term change and variability in the global ocean are affecting Australia's coastal seas and ecosystems. The NRS network provides an example of how a continental scaled observing systems can be developed to collect observations that integrate across physics, chemistry and biology. PMID:25517905
Validation of the BUV satellite ozone sensor using the rocket ozonesonde
NASA Technical Reports Server (NTRS)
Thomas, R. W. L.; Pearce, W. A.; Holland, A. C.; Wright, D. U.
1982-01-01
Satellite instruments such as the backscattered ultraviolet (BUV) apparatus, have been in operation for a number of years. One current difficulty is the validation of the ozone inferences obtained from the BUV measurements using independent instruments. For higher altitudes rocket instruments are necessary. Two instruments currently under development include a chemiluminescent detector described by Hilsenrath et al. (1969) and a filter photometer rocket ozonesonde (Rocoz) developed by Krueger and McBridge (1968). The present investigation is concerned with an analysis of the Rocoz system, the information content of the measurements, and the utility of the system for intercomparison with the BUV system. It is found that the sampling characteristics of the Rocoz and BUV systems exhibit some fundamental differences. However, their results can be related through knowledge of the relation between pressure and altitude. This is best obtained through the solution of the hypsometric equation using rocket temperature measurements.
Khoo, Bee Luan; Warkiani, Majid Ebrahimi; Tan, Daniel Shao-Weng; Bhagat, Ali Asgar S; Irwin, Darryl; Lau, Dawn Pingxi; Lim, Alvin S T; Lim, Kiat Hon; Krisna, Sai Sakktee; Lim, Wan-Teck; Yap, Yoon Sim; Lee, Soo Chin; Soo, Ross A; Han, Jongyoon; Lim, Chwee Teck
2014-01-01
Circulating tumor cells (CTCs) are cancer cells that can be isolated via liquid biopsy from blood and can be phenotypically and genetically characterized to provide critical information for guiding cancer treatment. Current analysis of CTCs is hindered by the throughput, selectivity and specificity of devices or assays used in CTC detection and isolation. Here, we enriched and characterized putative CTCs from blood samples of patients with both advanced stage metastatic breast and lung cancers using a novel multiplexed spiral microfluidic chip. This system detected putative CTCs under high sensitivity (100%, n = 56) (Breast cancer samples: 12-1275 CTCs/ml; Lung cancer samples: 10-1535 CTCs/ml) rapidly from clinically relevant blood volumes (7.5 ml under 5 min). Blood samples were completely separated into plasma, CTCs and PBMCs components and each fraction were characterized with immunophenotyping (Pan-cytokeratin/CD45, CD44/CD24, EpCAM), fluorescence in-situ hybridization (FISH) (EML4-ALK) or targeted somatic mutation analysis. We used an ultra-sensitive mass spectrometry based system to highlight the presence of an EGFR-activating mutation in both isolated CTCs and plasma cell-free DNA (cf-DNA), and demonstrate concordance with the original tumor-biopsy samples. We have clinically validated our multiplexed microfluidic chip for the ultra high-throughput, low-cost and label-free enrichment of CTCs. Retrieved cells were unlabeled and viable, enabling potential propagation and real-time downstream analysis using next generation sequencing (NGS) or proteomic analysis.
Design of New Procedures for Diagnosing Prevalent Diseases Using a Low-Cost Telemicroscopy System.
Prieto-Egido, Ignacio; González-Escalada, Alba; García-Giganto, Víctor; Martínez-Fernández, Andrés
2016-11-01
Currently, the diagnosis of prevalent diseases such as malaria, tuberculosis, or diarrheal diseases in rural areas of developing countries requires the displacement of the patient from their community health post to their reference health center or to ship a sample. This delays diagnosis and the treatment of disease. Conduct research to develop a new method for rapid low-cost diagnosis of prevalent diseases in rural areas of developing countries (malaria, tuberculosis, parasitic infections, vaginal infections, and cervical cancer). The study was divided into three phases. The first related to the drafting and validating of new protocols for the preparation of samples that should be adapted to be carried out in areas without power and with little trained personnel. The second phase consisted of developing a telemicroscopy system looking for low cost, software compatibility, and technical quality. Finally, the third phase evaluated the system as a diagnostic tool using direct observation with a conventional microscope as the gold standard. The validation of the new protocols showed that 100% of the vaginal swabs were processed correctly when using direct smear, while they were only 86.3% correct when using Gram stain; 68.3% of fecal samples were correctly processed using Kinyoun stain; 61.7% of blood samples when using thin film; and 83.8% when using thick film. Phase 2 permitted the development of a low-cost (<$250) and low-power (<15 W) telemicroscopy system that allows real-time consultation between health technicians and specialists. Finally, phase 3 proved that there was no difference between the diagnostics obtained by direct observation in a microscope and those ones obtained through the new telemicroscopy system. This study has verified the effectiveness of the telemicroscopy system as a diagnostic tool, given the complete agreement between the diagnoses made with it and those made with the gold standard.
Adaptive Patterns of Stress Responsivity: A Preliminary Investigation
ERIC Educational Resources Information Center
Del Giudice, Marco; Hinnant, J. Benjamin; Ellis, Bruce J.; El-Sheikh, Mona
2012-01-01
The adaptive calibration model (ACM) is an evolutionary-developmental theory of individual differences in stress responsivity. In this article, we tested some key predictions of the ACM in a middle childhood sample (N = 256). Measures of autonomic nervous system activity across the sympathetic and parasympathetic branches validated the 4-pattern…
Business Student Computer Self-Efficacy: Ten Years Later
ERIC Educational Resources Information Center
Karsten, Rex; Schmidt, Dennis
2008-01-01
This study analyzes computer self-efficacy for two independent samples of students enrolled in an introduction to information systems course in 1996 and 2006. We administered two validated and frequently employed measures of general computer self-efficacy to each group of students and collected demographic and computer-use data. Our findings…
Techniques for Down-Sampling a Measured Surface Height Map for Model Validation
NASA Technical Reports Server (NTRS)
Sidick, Erkin
2012-01-01
This software allows one to down-sample a measured surface map for model validation, not only without introducing any re-sampling errors, but also eliminating the existing measurement noise and measurement errors. The software tool of the current two new techniques can be used in all optical model validation processes involving large space optical surfaces
Nonclinical dose formulation analysis method validation and sample analysis.
Whitmire, Monica Lee; Bryan, Peter; Henry, Teresa R; Holbrook, John; Lehmann, Paul; Mollitor, Thomas; Ohorodnik, Susan; Reed, David; Wietgrefe, Holly D
2010-12-01
Nonclinical dose formulation analysis methods are used to confirm test article concentration and homogeneity in formulations and determine formulation stability in support of regulated nonclinical studies. There is currently no regulatory guidance for nonclinical dose formulation analysis method validation or sample analysis. Regulatory guidance for the validation of analytical procedures has been developed for drug product/formulation testing; however, verification of the formulation concentrations falls under the framework of GLP regulations (not GMP). The only current related regulatory guidance is the bioanalytical guidance for method validation. The fundamental parameters for bioanalysis and formulation analysis validations that overlap include: recovery, accuracy, precision, specificity, selectivity, carryover, sensitivity, and stability. Divergence in bioanalytical and drug product validations typically center around the acceptance criteria used. As the dose formulation samples are not true "unknowns", the concept of quality control samples that cover the entire range of the standard curve serving as the indication for the confidence in the data generated from the "unknown" study samples may not always be necessary. Also, the standard bioanalytical acceptance criteria may not be directly applicable, especially when the determined concentration does not match the target concentration. This paper attempts to reconcile the different practices being performed in the community and to provide recommendations of best practices and proposed acceptance criteria for nonclinical dose formulation method validation and sample analysis.
Design and Fabrication of an MRI-Compatible, Autonomous Incubation System.
Khalilzad-Sharghi, Vahid; Xu, Huihui
2015-10-01
Tissue engineers have long sought access to an autonomous, imaging-compatible tissue incubation system that, with minimum operator handling, can provide real-time visualization and quantification of cells, tissue constructs, and organs. This type of screening system, capable of operating noninvasively to validate tissue, can overcome current limitations like temperature shock, unsustainable cellular environments, sample contamination, and handling/stress. However, this type of system has been a major challenge, until now. Here, we describe the design, fabrication, and characterization of an innovative, autonomous incubation system that is compatible with a 9.4 T magnetic resonance imaging (MRI) scanner. Termed the e-incubator (patent pending; application number: 13/953,984), this microcontroller-based system is integrated into an MRI scanner and noninvasively screens cells and tissue cultures in an environment where temperature, pH, and media/gas handling are regulated. The 4-week study discussed herein details the continuous operation of the e-incubator for a tissue-engineered osteogenic construct, validated by LIVE/DEAD(®) cell assays and histology. The evolving MR quantitative parameters of the osteogenic construct were used as biomarkers for bone tissue engineering and to further validate the quality of the product noninvasively before harvesting. Importantly, the e-incubator reliably facilitates culturing cells and tissue constructs to create engineered tissues and/or investigate disease therapies.
Limberg, Brian J; Johnstone, Kevin; Filloon, Thomas; Catrenich, Carl
2016-09-01
Using United States Pharmacopeia-National Formulary (USP-NF) general method <1223> guidance, the Soleris(®) automated system and reagents (Nonfermenting Total Viable Count for bacteria and Direct Yeast and Mold for yeast and mold) were validated, using a performance equivalence approach, as an alternative to plate counting for total microbial content analysis using five representative microbes: Staphylococcus aureus, Bacillus subtilis, Pseudomonas aeruginosa, Candida albicans, and Aspergillus brasiliensis. Detection times (DTs) in the alternative automated system were linearly correlated to CFU/sample (R(2) = 0.94-0.97) with ≥70% accuracy per USP General Chapter <1223> guidance. The LOD and LOQ of the automated system were statistically similar to the traditional plate count method. This system was significantly more precise than plate counting (RSD 1.2-2.9% for DT, 7.8-40.6% for plate counts), was statistically comparable to plate counting with respect to variations in analyst, vial lots, and instruments, and was robust when variations in the operating detection thresholds (dTs; ±2 units) were used. The automated system produced accurate results, was more precise and less labor-intensive, and met or exceeded criteria for a valid alternative quantitative method, consistent with USP-NF general method <1223> guidance.
Gassner, Christoph; Rainer, Esther; Pircher, Elfriede; Markut, Lydia; Körmöczi, Günther F.; Jungbauer, Christof; Wessin, Dietmar; Klinghofer, Roswitha; Schennach, Harald; Schwind, Peter; Schönitzer, Diether
2009-01-01
Summary Background Validations of routinely used serological typing methods require intense performance evaluations typically including large numbers of samples before routine application. However, such evaluations could be improved considering information about the frequency of standard blood groups and their variants. Methods Using RHD and ABO population genetic data, a Caucasian-specific donor panel was compiled for a performance comparison of the three RhD and ABO serological typing methods MDmulticard (Medion Diagnostics), ID-System (DiaMed) and ScanGel (Bio-Rad). The final test panel included standard and variant RHD and ABO genotypes, e.g. RhD categories, partial and weak RhDs, RhD DELs, and ABO samples, mainly to interpret weak serological reactivity for blood group A specificity. All samples were from individuals recorded in our local DNA blood group typing database. Results For ‘standard’ blood groups, results of performance were clearly interpretable for all three serological methods compared. However, when focusing on specific variant phenotypes, pronounced differences in reaction strengths and specificities were observed between them. Conclusions A genetically and ethnically predefined donor test panel consisting of 93 individual samples only, delivered highly significant results for serological performance comparisons. Such small panels offer impressive representative powers, higher as such based on statistical chances and large numbers only. PMID:21113264
Development of a System Model for Non-Invasive Quantification of Bilirubin in Jaundice Patients
NASA Astrophysics Data System (ADS)
Alla, Suresh K.
Neonatal jaundice is a medical condition which occurs in newborns as a result of an imbalance between the production and elimination of bilirubin. Excess bilirubin in the blood stream diffuses into the surrounding tissue leading to a yellowing of the skin. An optical system integrated with a signal processing system is used as a platform to noninvasively quantify bilirubin concentration through the measurement of diffuse skin reflectance. Initial studies have lead to the generation of a clinical analytical model for neonatal jaundice which generates spectral reflectance data for jaundiced skin with varying levels of bilirubin concentration in the tissue. The spectral database built using the clinical analytical model is then used as a test database to validate the signal processing system in real time. This evaluation forms the basis for understanding the translation of this research to human trials. The clinical analytical model and signal processing system have been successful validated on three spectral databases. First spectral database is constructed using a porcine model as a surrogate for neonatal skin tissue. Samples of pig skin were soaked in bilirubin solutions of varying concentrations to simulate jaundice skin conditions. The resulting skins samples were analyzed with our skin reflectance systems producing bilirubin concentration values that show a high correlation (R2 = 0.94) to concentration of the bilirubin solution that each porcine tissue sample is soaked in. The second spectral database is the spectral measurements collected on human volunteers to quantify the different chromophores and other physical properties of the tissue such a Hematocrit, Hemoglobin etc. The third spectral database is the spectral data collected at different time periods from the moment a bruise is induced.
Validation of the Aura Microwave Limb Sounder Temperature and Geopotential Height Measurements
NASA Technical Reports Server (NTRS)
Schwartz, M. J.; Lambert, A.; Manney, G. L.; Read, W. G.; Livesey, N. J.; Froidevaux, L.; Ao, C. O.; Bernath, P. F.; Boone, C. D.; Cofield, R. E.;
2007-01-01
This paper describes the retrievals algorithm used to determine temperature and height from radiance measurements by the Microwave Limb Sounder on EOS Aura. MLS is a "limbscanning" instrument, meaning that it views the atmosphere along paths that do not intersect the surface - it actually looks forwards from the Aura satellite. This means that the temperature retrievals are for a "profile" of the atmosphere somewhat ahead of the satellite. Because of the need to view a finite sample of the atmosphere, the sample spans a box about 1.5km deep and several tens of kilometers in width; the optical characteristics of the atmosphere mean that the sample is representative of a tube about 200-300km long in the direction of view. The retrievals use temperature analyses from NASA's Goddard Earth Observing System, Version 5 (GEOS-5) data assimilation system as a priori states. The temperature retrievals are somewhat deperrdezt on these a priori states, especially in the lower stratosphere. An important part of the validation of any new dataset involves comparison with other, independent datasets. A large part of this study is concerned with such comparisons, using a number of independent space-based measurements obtained using different techniques, and with meteorological analyses. The MLS temperature data are shown to have biases that vary with height, but also depend on the validation dataset. MLS data are apparently biased slightly cold relative to correlative data in the upper troposphere and slightly warm in the middle stratosphere. A warm MLS bias in the upper stratosphere may be due to a cold bias in GEOS-5 temperatures.
Yfantopoulos, John N; Chantzaras, Athanasios E
2017-05-01
To validate and compare the psychometric properties of the EQ-5D-3L with the EQ-5D-5L classification systems in Greece. Participants (n = 2279) over 40 years old, sampled from the greater area of Athens using a multistage stratified quota sampling method, completed both EQ-5D versions, while information was also collected on socio-demographics and health-related characteristics. The EQ-5D-5L and EQ-5D-3L were evaluated in terms of agreement, ceiling effects, redistribution and inconsistency, informativity, and convergent and known-groups validity. The agreement between the EQ-5D-3L and EQ-5D-5L was high (ICC = 0.85). Ceiling effects decreased significantly in the EQ-5D-5L in all domains (P < 0.001), with "usual activities" (-21.4 %) and "self-care" (-20.1 %) showing the highest absolute and "anxiety/depression" the highest relative reduction (-32.46 %). Inconsistency was low (5.7 %). The increase in prevalence of problems was larger than the decrease in their severity, resulting in a lower mean health utility for the EQ-5D-5L. Overall absolute and relative informativity improved by 70.5 % and 16.4 %, respectively, in the EQ-5D-5L. Both instruments exhibited good convergent and known-groups validity, with evidence of a considerably better convergent performance and discriminatory ability of the EQ-5D-5L. Both EQ-5D versions demonstrated good construct validity and had consistent redistribution. The EQ-5D-5L system may be preferable to the EQ-5D-3L, as it exhibited superior performance in terms of lower ceiling effects, higher absolute and relative informativity, and improved convergent and known-groups validity efficiency.
Hybrid algorithm for simulating the collimated transmittance of homogeneous stratified turbid media
Cruzado, Beatriz Morales; Atencio, José Alberto Delgado; Vázquez y Montiel, Sergio; Gómez, Erick Sarmiento
2015-01-01
In this work we describe the development of a program that simulates the propagation of photons through refractive and reflecting optical components such as lenses, mirrors and stops that includes a biological tissue sample as the main issue to be investigated in order to get a simulated value of light distribution, in particular, of the unscattered light. The analysis of the photons that travel through the sample is based on the program Monte Carlo Multi-Layered with some modifications that consider a Gaussian beam as initial source of light. Position, directional cosines and weight of photons exiting the turbid media are used to propagate them through an optical system. As a mean of validation of the program, we selected a typical optical system for measurement of collimated transmittance. Therefore, several tests were carried out to find the optical system that gives the theoretical collimated transmittance at different values of the optical properties of the turbid media. Along this validation, the optimal experimental configuration is found. Using this results, a comparison between the simulated optimal configuration and the experimental set-up was done, by using a colloidal suspension as a turbid media. PMID:26137375
Visual Tracking Using 3D Data and Region-Based Active Contours
2016-09-28
adaptive control strategies which explicitly take uncertainty into account. Filtering methods ranging from the classical Kalman filters valid for...linear systems to the much more general particle filters also fit into this framework in a very natural manner. In particular, the particle filtering ...the number of samples required for accurate filtering increases with the dimension of the system noise. In our approach, we approximate curve
Design of a portable electronic nose for real-fake detection of liquors
NASA Astrophysics Data System (ADS)
Qi, Pei-Feng; Zeng, Ming; Li, Zhi-Hua; Sun, Biao; Meng, Qing-Hao
2017-09-01
Portability is a major issue that influences the practical application of electronic noses (e-noses). For liquors detection, an e-nose must preprocess the liquid samples (e.g., using evaporation and thermal desorption), which makes the portable design even more difficult. To realize convenient and rapid detection of liquors, we designed a portable e-nose platform that consists of hardware and software systems. The hardware system contains an evaporation/sampling module, a reaction module, a control/data acquisition and analysis module, and a power module. The software system provides a user-friendly interface and can achieve automatic sampling and data processing. This e-nose platform has been applied to the real-fake recognition of Chinese liquors. Through parameter optimization of a one-class support vector machine classifier, the error rate of the negative samples is greatly reduced, and the overall recognition accuracy is improved. The results validated the feasibility of the designed portable e-nose platform.
Gaviria, Marcela; Rivera, Vanessa; Muñoz-Cadavid, Cesar; Cano, Luz Elena; Naranjo, Tonny Williams
2015-01-01
Paracoccidioidomycosis is a systemic and endemic mycosis, restricted to tropical and subtropical areas of Latin America. The infection is caused by the thermal dimorphic fungus Paracoccidioides brasiliensis and Paracoccidioides lutzii. The diagnosis of paracoccidioidomycosis is usually performed by microscopic examination, culture and immunodiagnostic tests to respiratory specimens, body fluids and/or biopsies; however these methods require laboratory personnel with experience and several days to produce a result. In the present study, we have validated and evaluated a nested PCR assay targeting the gene encoding the Paracoccidioides gp43 membrane protein in 191 clinical samples: 115 samples from patients with proven infections other than paracoccidioidomycosis, 51 samples as negative controls, and 25 samples from patients diagnosed with paracoccidioidomycosis. Additionally, the specificity of the nested PCR assay was also evaluated using purified DNA isolated from cultures of different microorganisms (n=35) previously identified by culture and/or sequencing. The results showed that in our hands, this nested PCR assay for gp43 protein showed specificity and sensitivity rates of 100%. The optimized nested PCR conditions in our laboratory allowed detection down to 1fg of P. brasiliensis DNA. Copyright © 2015 Elsevier Editora Ltda. All rights reserved.
Suyagh, Maysa Faisal; Iheagwaram, Godwill; Kole, Prashant Laxman; Millership, Jeff; Collier, Paul; Halliday, Henry; McElnay, James C
2010-05-01
A selective and sensitive high-performance liquid chromatography method with UV detection for the determination of metronidazole in dried blood spots (DBS) has been developed and validated. DBS samples [spiked or patient samples] were prepared by applying blood (30 microL) to Guthrie cards. Discs (6 mm diameter) were punched from the cards and extracted using water containing the internal standard, tinidazole. The extracted sample was chromatographed without further treatment using a reversed phase system involving a Symmetry(R) C18 (5 microm, 3.9 x 150 mm) preceded by a Symmetry(R) guard column of matching chemistry and a detection wavelength of 317 nm. The mobile phase comprised acetonitrile/0.01 M phosphate solution (KH(2)PO(4)), pH 4.7, 15:85, v/v, with a flow rate of 1 mL/min. The calibration was linear over the range 2.5-50 mg/mL. The limits of detection and quantification were 0.6 and 1.8 microg/mL, respectively. The method has been applied to the determination of 203 DBS samples from neonatal patients for a phamacokinetic/pharmacodynamic study.
Determination of cocaine and metabolites in hair by column-switching LC-MS-MS analysis.
Alves, Marcela Nogueira Rabelo; Zanchetti, Gabriele; Piccinotti, Alberto; Tameni, Silvia; De Martinis, Bruno Spinosa; Polettini, Aldo
2013-07-01
A method for rapid, selective, and robust determination of cocaine (CO) and metabolites in 5-mg hair samples was developed and fully validated using a column-switching liquid chromatography-tandem mass spectrometry system (LC-MS-MS). Hair samples were decontaminated, segmented, incubated overnight in diluted HCl, and centrifuged, and the diluted (1:10 with distilled water) extracts were analyzed in positive ionization mode monitoring two reactions per analyte. Quantifier transitions were: m/z 304.2→182.2 for CO, m/z 290.1→168.1 for benzoylecgonine (BE), and m/z 318.2→196.2 for cocaethylene (CE). The lower limit of quantification (LLOQ) was set at 0.05 ng/mg for CO and CE, and 0.012 ng/mg for BE. Imprecision and inaccuracy at LLOQ were lower than 20 % for all analytes. Linearity ranged between 0.05 and 50.0 ng/mg for CO and CE and 0.012 and 12.50 ng/mg for BE. Selectivity, matrix effect, process efficiency, recovery, carryover, cross talk, and autosampler stability were also evaluated during validation. Eighteen real hair samples and five samples from a commercial proficiency testing program were comparatively examined with the proposed multidimensional chromatography coupled with tandem mass spectrometry procedure and our reference gas chromatography coupled to mass spectrometry (GC-MS) method. Compared with our reference GC-MS method, column-switching technique and the high sensitivity of the tandem mass spectrometry detection system allowed to significantly reduce sample amount (×10) with increased sensitivity (×2) and sample throughput (×4), to simplify sample preparation, and to avoid that interfering compounds and ions impaired the ionization and detection of the analytes and deteriorate the performance of the ion source.
Modeling the uncertainty of estimating forest carbon stocks in China
NASA Astrophysics Data System (ADS)
Yue, T. X.; Wang, Y. F.; Du, Z. P.; Zhao, M. W.; Zhang, L. L.; Zhao, N.; Lu, M.; Larocque, G. R.; Wilson, J. P.
2015-12-01
Earth surface systems are controlled by a combination of global and local factors, which cannot be understood without accounting for both the local and global components. The system dynamics cannot be recovered from the global or local controls alone. Ground forest inventory is able to accurately estimate forest carbon stocks at sample plots, but these sample plots are too sparse to support the spatial simulation of carbon stocks with required accuracy. Satellite observation is an important source of global information for the simulation of carbon stocks. Satellite remote-sensing can supply spatially continuous information about the surface of forest carbon stocks, which is impossible from ground-based investigations, but their description has considerable uncertainty. In this paper, we validated the Lund-Potsdam-Jena dynamic global vegetation model (LPJ), the Kriging method for spatial interpolation of ground sample plots and a satellite-observation-based approach as well as an approach for fusing the ground sample plots with satellite observations and an assimilation method for incorporating the ground sample plots into LPJ. The validation results indicated that both the data fusion and data assimilation approaches reduced the uncertainty of estimating carbon stocks. The data fusion had the lowest uncertainty by using an existing method for high accuracy surface modeling to fuse the ground sample plots with the satellite observations (HASM-SOA). The estimates produced with HASM-SOA were 26.1 and 28.4 % more accurate than the satellite-based approach and spatial interpolation of the sample plots, respectively. Forest carbon stocks of 7.08 Pg were estimated for China during the period from 2004 to 2008, an increase of 2.24 Pg from 1984 to 2008, using the preferred HASM-SOA method.
Quantizing and sampling considerations in digital phased-locked loops
NASA Technical Reports Server (NTRS)
Hurst, G. T.; Gupta, S. C.
1974-01-01
The quantizer problem is first considered. The conditions under which the uniform white sequence model for the quantizer error is valid are established independent of the sampling rate. An equivalent spectral density is defined for the quantizer error resulting in an effective SNR value. This effective SNR may be used to determine quantized performance from infinitely fine quantized results. Attention is given to sampling rate considerations. Sampling rate characteristics of the digital phase-locked loop (DPLL) structure are investigated for the infinitely fine quantized system. The predicted phase error variance equation is examined as a function of the sampling rate. Simulation results are presented and a method is described which enables the minimum required sampling rate to be determined from the predicted phase error variance equations.
Cessna, Julie M; Jim, Heather S L; Sutton, Steven K; Asvat, Yasmin; Small, Brent J; Salsman, John M; Zachariah, Babu; Fishman, Mayer; Field, Teresa; Fernandez, Hugo; Perez, Lia; Jacobsen, Paul B
2016-02-01
Fatigue is common among cancer patients and adversely impacts quality of life. As such, it is important to measure fatigue accurately in a way that is not burdensome to patients. The 7-item Patient Reported Outcome Measurement Information System (PROMIS) Cancer Fatigue Short Form scale was recently developed using item response theory (IRT). The current study evaluated the psychometric properties of this scale in two samples of cancer patients using classical test theory (CTT). Two samples were used: 121 men with prostate cancer and 136 patients scheduled to undergo hematopoietic cell transplantation (HCT) for hematologic cancer. All participants completed the PROMIS Cancer Fatigue Short Form as well as validated measures of fatigue, vitality, and depression. HCT patients also completed measures of anxiety, perceived stress, and a clinical interview designed to identify cases of cancer-related fatigue. PROMIS Cancer Fatigue Short Form items loaded on a single factor (CFI=0.948) and the scale demonstrated good internal consistency reliability in both samples (Cronbach's alphas>0.86). Correlations with psychosocial measures were significant (p values<.0001) and in the expected direction, offering evidence for convergent and concurrent validity. PROMIS Fatigue scores were significantly higher in patients who met case definition criteria for cancer-related fatigue (p<.0001), demonstrating criterion validity. The current study provides evidence that the PROMIS Cancer Fatigue Short Form is a reliable and valid measure of fatigue in cancer patients. Copyright © 2015 Elsevier Inc. All rights reserved.
Jansen, G J; Wildeboer-Veloo, A C; Tonk, R H; Franks, A H; Welling, G W
1999-09-01
An automated microscopy-based method using fluorescently labelled 16S rRNA-targeted oligonucleotide probes directed against the predominant groups of intestinal bacteria was developed and validated. The method makes use of the Leica 600HR image analysis system, a Kodak MegaPlus camera model 1.4 and a servo-controlled Leica DM/RXA ultra-violet microscope. Software for automated image acquisition and analysis was developed and tested. The performance of the method was validated using a set of four fluorescent oligonucleotide probes: a universal probe for the detection of all bacterial species, one probe specific for Bifidobacterium spp., a digenus-probe specific for Bacteroides spp. and Prevotella spp. and a trigenus-probe specific for Ruminococcus spp., Clostridium spp. and Eubacterium spp. A nucleic acid stain, 4',6-diamidino-2-phenylindole (DAPI), was also included in the validation. In order to quantify the assay-error, one faecal sample was measured 20 times using each separate probe. Thereafter faecal samples of 20 different volunteers were measured following the same procedure in order to quantify the error due to individual-related differences in gut flora composition. It was concluded that the combination of automated microscopy and fluorescent whole-cell hybridisation enables distinction in gut flora-composition between volunteers at a significant level. With this method it is possible to process 48 faecal samples overnight, with coefficients of variation ranging from 0.07 to 0.30.
Cessna, Julie M.; Jim, Heather S.L.; Sutton, Steven K.; Asvat, Yasmin; Small, Brent J.; Salsman, John M.; Zachariah, Babu; Fishman, Mayer; Field, Teresa; Fernandez, Hugo; Perez, Lia; Jacobsen, Paul B.
2016-01-01
Objective Fatigue is common among cancer patients and adversely impacts quality of life. As such, it is important to measure fatigue accurately in a way that is not burdensome to patients. The 7-item Patient Reported Outcome Measurement Information System (PROMIS) Cancer Fatigue Short Form scale was recently developed using item response theory (IRT). The current study evaluated the psychometric properties of this scale in two samples of cancer patients using classical test theory (CTT). Methods Two samples were used: 121 men with prostate cancer and 136 patients scheduled to undergo hematopoietic cell transplantation (HCT) for hematologic cancer. All participants completed the PROMIS Cancer Fatigue Short Form as well as validated measures of fatigue, vitality, and depression. HCT patients also completed measures of anxiety, perceived stress, and a clinical interview designed to identify cases of cancer -related fatigue. Results PROMIS Cancer Fatigue Short Form items loaded on a single factor (CFI = 0.948) and the scale demonstrated good internal consistency reliability in both samples (Cronbach’s alphas > 0.86). Correlations with psychosocial measures were significant (p-values < .0001) and in the expected direction, offering evidence for convergent and concurrent validity. PROMIS Fatigue scores were significantly higher in patients who met case definition criteria for cancer-related fatigue (p < .0001), demonstrating criterion validity. Conclusion The current study provides evidence that the PROMIS Cancer Fatigue Short Form is a reliable and valid measure of fatigue in cancer patients. PMID:26800633
Full-Scale Spacecraft Simulator Design for a 2D Zero Gravity Small Body Surface Sampling Validation
NASA Astrophysics Data System (ADS)
Mongelli, Marco
NASA is developing several Touch-And-Go (TAG) classes of missions. These types of missions like the OSIRIS-REx asteroid sample return [1] or a comet sample return mission (CSSR)[2], consist usually in three phases: propulsive approach to the target, sampling and propulsion to move the spacecraft away from the target. The development of TAG mission, from concept to realization, is usually divided in two phases: Phase I discusses the major trades that could affect the mission architecture; Phase II focuses in detail on the design. This project of a spacecraft emulator fits into phase II and specifically on the way the spacecraft could react in absence of gravity while the Sample Acquisition System (SAS) is collecting the sample. A full-scale spacecraft on a 2D zero-friction environment has been designed. Also a propulsion system has been implemented to re-create the full dynamics of a spacecraft in space.
Quantifying Soiling Loss Directly From PV Yield
Deceglie, Michael G.; Micheli, Leonardo; Muller, Matthew
2018-01-23
Soiling of photovoltaic (PV) panels is typically quantified through the use of specialized sensors. Here, we describe and validate a method for estimating soiling loss experienced by PV systems directly from system yield without the need for precipitation data. The method, termed the stochastic rate and recovery (SRR) method, automatically detects soiling intervals in a dataset, then stochastically generates a sample of possible soiling profiles based on the observed characteristics of each interval. In this paper, we describe the method, validate it against soiling station measurements, and compare it with other PV-yield-based soiling estimation methods. The broader application of themore » SRR method will enable the fleet scale assessment of soiling loss to facilitate mitigation planning and risk assessment.« less
Quantifying Soiling Loss Directly From PV Yield
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deceglie, Michael G.; Micheli, Leonardo; Muller, Matthew
Soiling of photovoltaic (PV) panels is typically quantified through the use of specialized sensors. Here, we describe and validate a method for estimating soiling loss experienced by PV systems directly from system yield without the need for precipitation data. The method, termed the stochastic rate and recovery (SRR) method, automatically detects soiling intervals in a dataset, then stochastically generates a sample of possible soiling profiles based on the observed characteristics of each interval. In this paper, we describe the method, validate it against soiling station measurements, and compare it with other PV-yield-based soiling estimation methods. The broader application of themore » SRR method will enable the fleet scale assessment of soiling loss to facilitate mitigation planning and risk assessment.« less
Reduction of Martian Sample Return Mission Launch Mass with Solar Sail Propulsion
NASA Technical Reports Server (NTRS)
Russell, Tiffany E.; Heaton, Andy F.; Young, Roy; Baysinger, Mike; Schnell, Andrew R.
2013-01-01
Solar sails have the potential to provide mass and cost savings for spacecraft traveling within the innter solar system. Companies like L'Garde have demonstrated sail manufacturability and various i-space development methods. The purpose of this study was to evaluate a current Mars sample return architecture and to determine how cost and mass would be reduced by incorporating a solar sail propulsion system. The team validated the design proposed by L'Garde, and scaled the design based on a trajectory analysis. Using the solar sail design reduced the required mass, eliminating one of the three launches required in the original architecture.
Reduction of Martian Sample Return Mission Launch Mass with Solar Sail Propulsion
NASA Technical Reports Server (NTRS)
Russell, Tiffany E.; Heaton, Andrew; Thomas, Scott; Thomas, Dan; Young, Roy; Baysinger, Mike; Capizzo, Pete; Fabisinski, Leo; Hornsby, Linda; Maples, Dauphne;
2013-01-01
Solar sails have the potential to provide mass and cost savings for spacecraft traveling within the inner solar system. Companies like L'Garde have demonstrated sail manufacturability and various in-space deployment methods. The purpose of this study was to evaluate a current Mars sample return architecture and to determine how cost and mass would be reduced by incorporating a solar sail propulsion system. The team validated the design proposed by L'Garde, and scaled the design based on a trajectory analysis. Using the solar sail design reduced the required mass, eliminating one of the three launches required in the original architecture.
Psoma, A K; Pasias, I N; Rousis, N I; Barkonikos, K A; Thomaidis, N S
2014-05-15
A rapid, sensitive, accurate and precise method for the determination of Pb, Cd, As and Cu in seafood and fish feed samples by Simultaneous Electrothermal Atomic Absorption Spectrometry was developed in regard to Council Directive 333/2007EC and ISO/IEC 17025 (2005). Different approaches were investigated in order to shorten the analysis time, always taking into account the sensitivity. For method validation, precision (repeatability and reproducibility) and accuracy by addition recovery tests have been assessed as performance criteria. The expanded uncertainties based on the Eurachem/Citac Guidelines were calculated. The method was accredited by the Hellenic Accreditation System and it was applied for an 8 years study in seafood (n=202) and fish feeds (n=275) from the Greek market. The annual and seasonal variation of the elemental content and correlation among the elemental content in fish feeds and the respective fish samples were also accomplished. Copyright © 2013 Elsevier Ltd. All rights reserved.
Kerig, Patricia K; Charak, Ruby; Chaplo, Shannon D; Bennett, Diana C; Armour, Cherie; Modrowski, Crosby A; McGee, Andrew B
2016-09-01
The inclusion of a dissociative subtype in the Diagnostic and Statistical Manual of Mental Disorders (5th ed.; DSM–5 ) criteria for the diagnosis of posttraumatic stress disorder (PTSD) has highlighted the need for valid and reliable measures of dissociative symptoms across developmental periods. The Adolescent Dissociative Experiences Scale (A-DES) is 1 of the few measures validated for young persons, but previous studies have yielded inconsistent results regarding its factor structure. Further, research to date on the A-DES has been based upon nonclinical samples of youth or those without a known history of trauma. To address these gaps in the literature, the present study investigated the factor structure and construct validity of the A-DES in a sample of highly trauma-exposed youth involved in the juvenile justice system. A sample of 784 youth (73.7% boys) recruited from a detention center completed self-report measures of trauma exposure and the A-DES, a subset of whom (n = 212) also completed a measure of PTSD symptoms. Confirmatory factor analyses revealed a best fitting 3-factor structure comprised of depersonalization or derealization, amnesia, and loss of conscious control, with configural and metric invariance across gender. Logistic regression analyses indicated that the depersonalization or derealization factor effectively distinguished between those youth who did and did not likely meet criteria for a diagnosis of PTSD as well as those with PTSD who did and did not likely meet criteria for the dissociative subtype. These results provide support for the multidimensionality of the construct of posttraumatic dissociation and contribute to the understanding of the dissociative subtype of PTSD among adolescents. (PsycINFO Database Record PsycINFO Database Record (c) 2016 APA, all rights reserved
Floriani, Gisele; Gasparetto, João Cleverson; Pontarolo, Roberto; Gonçalves, Alan Guilherme
2014-02-01
Here, an HPLC-DAD method was developed and validated for simultaneous determination of cocaine, two cocaine degradation products (benzoylecgonine and benzoic acid), and the main adulterants found in products based on cocaine (caffeine, lidocaine, phenacetin, benzocaine and diltiazem). The new method was developed and validated using an XBridge C18 4.6mm×250mm, 5μm particle size column maintained at 60°C. The mobile phase consisted of a gradient of acetonitrile and ammonium formate 0.05M - pH 3.1, eluted at 1.0mL/min. The volume of injection was 10μL and the DAD detector was set at 274nm. Method validation assays demonstrated suitable sensitivity, selectivity, linearity, precision and accuracy. For selectivity assay, a MS detection system could be directly adapted to the method without the need of any change in the chromatographic conditions. The robustness study indicated that the flow rate, temperature and pH of the mobile phase are critical parameters and should not be changed considering the conditions herein determined. The new method was then successfully applied for determining cocaine, benzoylecgonine, benzoic acid, caffeine, lidocaine, phenacetin, benzocaine and diltiazem in 115 samples, seized in Brazil (2007-2012), which consisted of cocaine paste, cocaine base and salt cocaine samples. This study revealed cocaine contents that ranged from undetectable to 97.2%, with 97 samples presenting at least one of the degradation products or adulterants here evaluated. All of the studied degradation products and adulterants were observed among the seized samples, justifying the application of the method, which can be used as a screening and quantification tool in forensic analysis. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Rosa-Rizzotto, M; Visonà Dalla Pozza, L; Corlatti, A; Luparia, A; Marchi, A; Molteni, F; Facchin, P; Pagliano, E; Fedrizzi, E
2014-10-01
In hemiplegic children, the recognition of the activity limitation pattern and the possibility of grading its severity are relevant for clinicians while planning interventions, monitoring results, predicting outcomes. Aim of the study is to examine the reliability and validity of Besta Scale, an instrument used to measure in hemiplegic children from 18 months to 12 years of age both grasp on request (capacity) and spontaneous use of upper limb (performance) in bimanual play activities and in ADL. Psychometric analysis of reliability and of validity of the Besta scale was performed. Outpatient study sample Reliability study: A sample of 39 patients was enrolled. The administration of Besta scale was video-recorded in a standardized manner. All videos were scored by 20 independent raters on subsequent viewing. 3 raters randomly selected from the 20-raters group rescored the same video two years later for intra-rater reliability. Intra and inter-rater reliability were calculated using Intraclass Correlation Coefficient (ICC) and Kendall's coefficient (K), respectively. Internal consistency reliability was assessed using Alpha's Chronbach coefficient. Validity study: a sample of 105 children was assessed 5 times (at t0 and 2, 3, 6 and 12 months later) by 20 independent raters. Each patient underwent at the same time to QUEST and Besta scale administration and assessment. Criterion validity was calculated using rho-Pearson coefficient. Reliability study: The inter-rater reliability calculated with Kendall's coefficient resulted moderate K=0.47. The intra-rater (or test-retest) reliability for 3 raters was excellent (ICC=0.927). The Cronbach's alpha for internal consistency was 0.972. Validity study: Besta scale showed a good criterion validity compared to QUEST increasing by age and severity of impairment. Rho Pearson's correlation coefficient r was 0.81 (P<0.0001). Limitations. Besta scales in infants finds hard to distinguish between mild to moderately impaired hand function. Besta scale scoring system is a valid and reliable tool, utilizable in a clinical setting to monitor evolution of unimanual and bimanual manipulation and to distinguish hand's capacity from performance.
Advanced Engine Health Management Applications of the SSME Real-Time Vibration Monitoring System
NASA Technical Reports Server (NTRS)
Fiorucci, Tony R.; Lakin, David R., II; Reynolds, Tracy D.; Turner, James E. (Technical Monitor)
2000-01-01
The Real Time Vibration Monitoring System (RTVMS) is a 32-channel high speed vibration data acquisition and processing system developed at Marshall Space Flight Center (MSFC). It Delivers sample rates as high as 51,200 samples/second per channel and performs Fast Fourier Transform (FFT) processing via on-board digital signal processing (DSP) chips in a real-time format. Advanced engine health assessment is achieved by utilizing the vibration spectra to provide accurate sensor validation and enhanced engine vibration redlines. Discrete spectral signatures (such as synchronous) that are indicators of imminent failure can be assessed and utilized to mitigate catastrophic engine failures- a first in rocket engine health assessment. This paper is presented in viewgraph form.
Risk of malnutrition (over and under-nutrition): validation of the JaNuS screening tool.
Donini, Lorenzo M; Ricciardi, Laura Maria; Neri, Barbara; Lenzi, Andrea; Marchesini, Giulio
2014-12-01
Malnutrition (over and under-nutrition) is highly prevalent in patients admitted to hospital and it is a well-known risk factor for increased morbidity and mortality. Nutritional problems are often misdiagnosed, and especially the coexistence of over and undernutrition is not usually recognized. We aimed to develop and validate a screening tool for the easy detection and reporting of both undernutrition and overnutrition, specifically identifying the clinical conditions where the two types of malnutrition coexist. The study consisted of three phases: 1) selection of an appropriate study population (estimation sample) and of the hospital admission parameters to identify overnutrition and undernutrition; 2) combination of selected variables to create a screening tool to assess the nutritional risk in case of undernutrition, overnutrition, or the copresence of both the conditions, to be used by non-specialist health care professionals; 3) validation of the screening tool in a different patient sample (validation sample). Two groups of variables (12 for undernutrition, 7 for overnutrition) were identified in separate logistic models for their correlation with the outcome variables. Both models showed high efficacy, sensitivity and specificity (overnutrition, 97.7%, 99.6%, 66.6%, respectively; undernutrition, 84.4%, 83.6%, 84.8%). The logistic models were used to construct a two-faced test (named JaNuS - Just A Nutritional Screening) fitting into a two-dimension Cartesian coordinate graphic system. In the validation sample the JaNuS test confirmed its predictive value. Internal consistency and test-retest analysis provide evidence for the reliability of the test. The study provides a screening tool for the assessment of the nutritional risk, based on parameters easy-to-use by health care personnel lacking nutritional competence and characterized by excellent predictive validity. The test might be confidently applied in the clinical setting to determine the importance of malnutrition (including the copresence of over and undernutrition) as a risk factor for morbidity and mortality. Copyright © 2013 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Lehmann, Sabrina; Kieliba, Tobias; Beike, Justus; Thevis, Mario; Mercer-Chalmers-Bender, Katja
2017-10-01
A detailed description is given of the development and validation of a fully automated in-line solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) method capable of detecting 90 central-stimulating new psychoactive substances (NPS) and 5 conventional amphetamine-type stimulants (amphetamine, 3,4-methylenedioxy-methamphetamine (MDMA), 3,4-methylenedioxy-amphetamine (MDA), 3,4-methylenedioxy-N-ethyl-amphetamine (MDEA), methamphetamine) in serum. The aim was to apply the validated method to forensic samples. The preparation of 150μL of serum was performed by an Instrument Top Sample Preparation (ITSP)-SPE with mixed mode cation exchanger cartridges. The extracts were directly injected into an LC-MS/MS system, using a biphenyl column and gradient elution with 2mM ammonium formate/0.1% formic acid and acetonitrile/0.1% formic acid as mobile phases. The chromatographic run time amounts to 9.3min (including re-equilibration). The total cycle time is 11min, due to the interlacing between sample preparation and analysis. The method was fully validated using 69 NPS and five conventional amphetamine-type stimulants, according to the guidelines of the Society of Toxicological and Forensic Chemistry (GTFCh). The guidelines were fully achieved for 62 analytes (with a limit of detection (LOD) between 0.2 and 4μg/L), whilst full validation was not feasible for the remaining 12 analytes. For the fully validated analytes, the method achieved linearity in the 5μg/L (lower limit of quantification, LLOQ) to 250μg/L range (coefficients of determination>0.99). Recoveries for 69 of these compounds were greater than 50%, with relative standard deviations≤15%. The validated method was then tested for its capability in detecting a further 21 NPS, thus totalling 95 tested substances. An LOD between 0.4 and 1.6μg/L was obtained for these 21 additional qualitatively-measured substances. The method was subsequently successfully applied to 28 specimens from routine forensic case work, of which 7 samples were determined to be positive for NPS consumption. Copyright © 2017 Elsevier B.V. All rights reserved.
40 CFR 761.392 - Preparing validation study samples.
Code of Federal Regulations, 2014 CFR
2014-07-01
... establish a surface concentration to be included in the standard operating procedure. The surface levels of... Under § 761.79(d)(4) § 761.392 Preparing validation study samples. (a)(1) To validate a procedure to... surfaces must be ≥20 µg/100 cm2. (2) To validate a procedure to decontaminate a specified surface...
40 CFR 761.392 - Preparing validation study samples.
Code of Federal Regulations, 2012 CFR
2012-07-01
... establish a surface concentration to be included in the standard operating procedure. The surface levels of... Under § 761.79(d)(4) § 761.392 Preparing validation study samples. (a)(1) To validate a procedure to... surfaces must be ≥20 µg/100 cm2. (2) To validate a procedure to decontaminate a specified surface...
40 CFR 761.392 - Preparing validation study samples.
Code of Federal Regulations, 2013 CFR
2013-07-01
... establish a surface concentration to be included in the standard operating procedure. The surface levels of... Under § 761.79(d)(4) § 761.392 Preparing validation study samples. (a)(1) To validate a procedure to... surfaces must be ≥20 µg/100 cm2. (2) To validate a procedure to decontaminate a specified surface...
Vallejo-Medina, Pablo; Pérez-Durán, Claudia; Saavedra-Roa, Alejandro
2018-04-01
The Female Sexual Function Index (FSFI) subjectively explores the dimensions of female sexual functioning. This research undertook to adapt and validate the FSFI to Spanish language in a Colombian sample. To this effect, this study was conducted in two steps, namely: (1) cultural adaptation of the scale with the collaboration of seven experts; and (2) preliminary validation of the scale in a sample of 925 participants. Reliability indices were appropriate in this sample, and external validity in relation to other measures showed significant relationships. Findings suggest that the FSFI is reliable and valid in Spanish for a Colombian population. Further research is needed to establish the test-retest reliability and discriminant validity of this Spanish version.
Wille, Sarah M R; Di Fazio, Vincent; Ramírez-Fernandez, Maria del Mar; Kummer, Natalie; Samyn, Nele
2013-02-01
"Driving under the influence of drugs" (DUID) has a large impact on the worldwide mortality risk. Therefore, DUID legislations based on impairment or analytical limits are adopted. Drug detection in oral fluid is of interest due to the ease of sampling during roadside controls. The prevalence of Δ9-tetrahydrocannabinol (THC) in seriously injured drivers ranges from 0.5% to 7.6% in Europe. For these reasons, the quantification of THC in oral fluid collected with 3 alternative on-site collectors is presented and discussed in this publication. An ultra-performance liquid chromatography-mass spectrometric quantification method for THC in oral fluid samples collected with the StatSure (Diagnostic Systems), Quantisal (Immunalysis), and Certus (Concateno) devices was validated according to the international guidelines. Small sample volumes of 100-200 μL were extracted using hexane. Special attention was paid to factors such as matrix effects, THC adsorption onto the collector, and stability in the collection fluid. A relatively high-throughput analysis was developed and validated according to ISO 17025 requirements. Although the effects of the matrix on the quantification could be minimized using a deuterated internal standard, and stability was acceptable according the validation data, adsorption of THC onto the collectors was a problem. For the StatSure device, THC was totally recovered from the collector pad after storage for 24 hours at room temperature or 7 days at 4°C. A loss of 15%-25% was observed for the Quantisal collector, whereas the recovery from the Certus device was irreproducible (relative standard deviation, 44%-85%) and low (29%-80%). During the roadside setting, a practical problem arose: small volumes of oral fluid (eg, 300 μL) were collected. However, THC was easily detected and concentrations ranged from 8 to 922 ng/mL in neat oral fluid. A relatively high-throughput analysis (40 samples in 4 hours) adapted for routine DUID analysis was developed and validated for THC quantification in oral fluid samples collected from drivers under the influence of cannabis.
Development of the prototype pneumatic transfer system for ITER neutron activation system.
Cheon, M S; Seon, C R; Pak, S; Lee, H G; Bertalot, L
2012-10-01
The neutron activation system (NAS) measures neutron fluence at the first wall and the total neutron flux from the ITER plasma, providing evaluation of the fusion power for all operational phases. The pneumatic transfer system (PTS) is one of the key components of the NAS for the proper operation of the system, playing a role of transferring encapsulated samples between the capsule loading machine, irradiation stations, counting stations, and disposal bin. For the validation and the optimization of the design, a prototype of the PTS was developed and capsule transfer tests were performed with the developed system.
Jäger, Anne C; Alvarez, Michelle L; Davis, Carey P; Guzmán, Ernesto; Han, Yonmee; Way, Lisa; Walichiewicz, Paulina; Silva, David; Pham, Nguyen; Caves, Glorianna; Bruand, Jocelyne; Schlesinger, Felix; Pond, Stephanie J K; Varlaro, Joe; Stephens, Kathryn M; Holt, Cydne L
2017-05-01
Human DNA profiling using PCR at polymorphic short tandem repeat (STR) loci followed by capillary electrophoresis (CE) size separation and length-based allele typing has been the standard in the forensic community for over 20 years. Over the last decade, Next-Generation Sequencing (NGS) matured rapidly, bringing modern advantages to forensic DNA analysis. The MiSeq FGx™ Forensic Genomics System, comprised of the ForenSeq™ DNA Signature Prep Kit, MiSeq FGx™ Reagent Kit, MiSeq FGx™ instrument and ForenSeq™ Universal Analysis Software, uses PCR to simultaneously amplify up to 231 forensic loci in a single multiplex reaction. Targeted loci include Amelogenin, 27 common, forensic autosomal STRs, 24 Y-STRs, 7 X-STRs and three classes of single nucleotide polymorphisms (SNPs). The ForenSeq™ kit includes two primer sets: Amelogenin, 58 STRs and 94 identity informative SNPs (iiSNPs) are amplified using DNA Primer Set A (DPMA; 153 loci); if a laboratory chooses to generate investigative leads using DNA Primer Set B, amplification is targeted to the 153 loci in DPMA plus 22 phenotypic informative (piSNPs) and 56 biogeographical ancestry SNPs (aiSNPs). High-resolution genotypes, including detection of intra-STR sequence variants, are semi-automatically generated with the ForenSeq™ software. This system was subjected to developmental validation studies according to the 2012 Revised SWGDAM Validation Guidelines. A two-step PCR first amplifies the target forensic STR and SNP loci (PCR1); unique, sample-specific indexed adapters or "barcodes" are attached in PCR2. Approximately 1736 ForenSeq™ reactions were analyzed. Studies include DNA substrate testing (cotton swabs, FTA cards, filter paper), species studies from a range of nonhuman organisms, DNA input sensitivity studies from 1ng down to 7.8pg, two-person human DNA mixture testing with three genotype combinations, stability analysis of partially degraded DNA, and effects of five commonly encountered PCR inhibitors. Calculations from ForenSeq™ STR and SNP repeatability and reproducibility studies (1ng template) indicate 100.0% accuracy of the MiSeq FGx™ System in allele calling relative to CE for STRs (1260 samples), and >99.1% accuracy relative to bead array typing for SNPs (1260 samples for iiSNPs, 310 samples for aiSNPs and piSNPs), with >99.0% and >97.8% precision, respectively. Call rates of >99.0% were observed for all STRs and SNPs amplified with both ForenSeq™ primer mixes. Limitations of the MiSeq FGx™ System are discussed. Results described here demonstrate that the MiSeq FGx™ System meets forensic DNA quality assurance guidelines with robust, reliable, and reproducible performance on samples of various quantities and qualities. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Rosing, H.; Hillebrand, M. J. X.; Blesson, S.; Mengesha, B.; Diro, E.; Hailu, A.; Schellens, J. H. M.; Beijnen, J. H.
2016-01-01
To facilitate future pharmacokinetic studies of combination treatments against leishmaniasis in remote regions in which the disease is endemic, a simple cheap sampling method is required for miltefosine quantification. The aims of this study were to validate a liquid chromatography-tandem mass spectrometry method to quantify miltefosine in dried blood spot (DBS) samples and to validate its use with Ethiopian patients with visceral leishmaniasis (VL). Since hematocrit (Ht) levels are typically severely decreased in VL patients, returning to normal during treatment, the method was evaluated over a range of clinically relevant Ht values. Miltefosine was extracted from DBS samples using a simple method of pretreatment with methanol, resulting in >97% recovery. The method was validated over a calibration range of 10 to 2,000 ng/ml, and accuracy and precision were within ±11.2% and ≤7.0% (≤19.1% at the lower limit of quantification), respectively. The method was accurate and precise for blood spot volumes between 10 and 30 μl and for Ht levels of 20 to 35%, although a linear effect of Ht levels on miltefosine quantification was observed in the bioanalytical validation. DBS samples were stable for at least 162 days at 37°C. Clinical validation of the method using paired DBS and plasma samples from 16 VL patients showed a median observed DBS/plasma miltefosine concentration ratio of 0.99, with good correlation (Pearson's r = 0.946). Correcting for patient-specific Ht levels did not further improve the concordance between the sampling methods. This successfully validated method to quantify miltefosine in DBS samples was demonstrated to be a valid and practical alternative to venous blood sampling that can be applied in future miltefosine pharmacokinetic studies with leishmaniasis patients, without Ht correction. PMID:26787691
Optimal Control for Aperiodic Dual-Rate Systems With Time-Varying Delays
Salt, Julián; Guinaldo, María; Chacón, Jesús
2018-01-01
In this work, we consider a dual-rate scenario with slow input and fast output. Our objective is the maximization of the decay rate of the system through the suitable choice of the n-input signals between two measures (periodic sampling) and their times of application. The optimization algorithm is extended for time-varying delays in order to make possible its implementation in networked control systems. We provide experimental results in an air levitation system to verify the validity of the algorithm in a real plant. PMID:29747441
Optimal Control for Aperiodic Dual-Rate Systems With Time-Varying Delays.
Aranda-Escolástico, Ernesto; Salt, Julián; Guinaldo, María; Chacón, Jesús; Dormido, Sebastián
2018-05-09
In this work, we consider a dual-rate scenario with slow input and fast output. Our objective is the maximization of the decay rate of the system through the suitable choice of the n -input signals between two measures (periodic sampling) and their times of application. The optimization algorithm is extended for time-varying delays in order to make possible its implementation in networked control systems. We provide experimental results in an air levitation system to verify the validity of the algorithm in a real plant.
Investigation of real tissue water equivalent path lengths using an efficient dose extinction method
NASA Astrophysics Data System (ADS)
Zhang, Rongxiao; Baer, Esther; Jee, Kyung-Wook; Sharp, Gregory C.; Flanz, Jay; Lu, Hsiao-Ming
2017-07-01
For proton therapy, an accurate conversion of CT HU to relative stopping power (RSP) is essential. Validation of the conversion based on real tissue samples is more direct than the current practice solely based on tissue substitutes and can potentially address variations over the population. Based on a novel dose extinction method, we measured water equivalent path lengths (WEPL) on animal tissue samples to evaluate the accuracy of CT HU to RSP conversion and potential variations over a population. A broad proton beam delivered a spread out Bragg peak to the samples sandwiched between a water tank and a 2D ion-chamber detector. WEPLs of the samples were determined from the transmission dose profiles measured as a function of the water level in the tank. Tissue substitute inserts and Lucite blocks with known WEPLs were used to validate the accuracy. A large number of real tissue samples were measured. Variations of WEPL over different batches of tissue samples were also investigated. The measured WEPLs were compared with those computed from CT scans with the Stoichiometric calibration method. WEPLs were determined within ±0.5% percentage deviation (% std/mean) and ±0.5% error for most of the tissue surrogate inserts and the calibration blocks. For biological tissue samples, percentage deviations were within ±0.3%. No considerable difference (<1%) in WEPL was observed for the same type of tissue from different sources. The differences between measured WEPLs and those calculated from CT were within 1%, except for some bony tissues. Depending on the sample size, each dose extinction measurement took around 5 min to produce ~1000 WEPL values to be compared with calculations. This dose extinction system measures WEPL efficiently and accurately, which allows the validation of CT HU to RSP conversions based on the WEPL measured for a large number of samples and real tissues.
Desmarchelier, Aurélien; Anizan, Sébastien; Minh Tien, Mai; Savoy, Marie-Claude; Bion, Cindy
2018-04-01
An LC-MS/MS method is presented for screening five tetracyclines and their epimers in a broad range of food products. The scope of matrices includes meat-, fish-, seafood-based products, various dairy ingredients, infant formulae and fats. The method principle is based on a liquid-liquid extraction with aqueous ethylenediaminetetraacetic acid (EDTA) and acetonitrile followed by a freezing step to promote phase separation at low temperature. After defatting with hexane, sample extracts were evaporated and reconstituted before injection onto the LC-MS/MS system. The addition of oxalic acid in the aqueous mobile phase was mandatory to maintain good peak shape and sensitivity over the run. The screening is based upon a double preparation of each sample, one 'as such' and a second one with the analytes spiked in the sample, in order to mitigate the risk of false negative response. The method was validated according to the European Community Reference Laboratories Residues Guidelines. A total of 93 samples were included in the validation by two independent laboratories giving both false-negative and false-positive rates at 0% for all compounds. Over the last two years, 2600 samples were analysed routinely and only one chicken sample was found above the regulatory limit.
Evidence on existing caries risk assessment systems: are they predictive of future caries?
Tellez, M; Gomez, J; Pretty, I; Ellwood, R; Ismail, A I
2013-02-01
To critically appraise evidence for the prediction of caries using four caries risk assessment (CRA) systems/guidelines (Cariogram, Caries Management by Risk Assessment (CAMBRA), American Dental Association (ADA), and American Academy of Pediatric Dentistry (AAPD)). This review focused on prospective cohort studies or randomized controlled trials. A systematic search strategy was developed to locate papers published in Medline Ovid and Cochrane databases. The search identified 539 scientific reports, and after title and abstract review, 137 were selected for full review and 14 met the following inclusion criteria: (i) used as validating criterion caries incidence/increment, (ii) involved human subjects and natural carious lesions, and (iii) published in peer-reviewed journals. In addition, papers were excluded if they met one or more of the following criteria: (i) incomplete description of sample selection, outcomes, or small sample size and (ii) not meeting the criteria for best evidence under the prognosis category of the Oxford Centre for Evidence-Based Medicine. There are wide variations among the systems in terms of definitions of caries risk categories, type and number of risk factors/markers, and disease indicators. The Cariogram combined sensitivity and specificity for predicting caries in permanent dentition ranges from 110 to 139 and is the only system for which prospective studies have been conducted to assess its validity. The Cariogram had limited prediction utility in preschool children, and a moderate to good performance for sorting out elderly individuals into caries risk groups. One retrospective analysis on CAMBRA's CRA reported higher incidence of cavitated lesions among those assessed as extreme-risk patients when compared with those at low risk. The evidence on the validity for existing systems for CRA is limited. It is unknown if the identification of high-risk individuals can lead to more effective long-term patient management that prevents caries initiation and arrests or reverses the progression of lesions. There is an urgent need to develop valid and reliable methods for caries risk assessment that are based on best evidence for prediction and disease management rather than opinions of experts.
Ishikawa, Tomokazu; Yoneyama, Tohru; Tobisawa, Yuki; Hatakeyama, Shingo; Kurosawa, Tatsuo; Nakamura, Kenji; Narita, Shintaro; Mitsuzuka, Koji; Duivenvoorden, Wilhelmina; Pinthus, Jehonathan H.; Hashimoto, Yasuhiro; Koie, Takuya; Habuchi, Tomonori; Arai, Yoichi; Ohyama, Chikara
2017-01-01
The low specificity of the prostate-specific antigen (PSA) for early detection of prostate cancer (PCa) is a major issue worldwide. The aim of this study to examine whether the serum PCa-associated α2,3-linked sialyl N-glycan-carrying PSA (S2,3PSA) ratio measured by automated micro-total immunoassay systems (μTAS system) can be applied as a diagnostic marker of PCa. The μTAS system can utilize affinity-based separation involving noncovalent interaction between the immunocomplex of S2,3PSA and Maackia amurensis lectin to simultaneously determine concentrations of free PSA and S2,3PSA. To validate quantitative performance, both recombinant S2,3PSA and benign-associated α2,6-linked sialyl N-glycan-carrying PSA (S2,6PSA) purified from culture supernatant of PSA cDNA transiently-transfected Chinese hamster ovary (CHO)-K1 cells were used as standard protein. Between 2007 and 2016, fifty patients with biopsy-proven PCa were pair-matched for age and PSA levels, with the same number of benign prostatic hyperplasia (BPH) patients used to validate the diagnostic performance of serum S2,3PSA ratio. A recombinant S2,3PSA- and S2,6PSA-spiked sample was clearly discriminated by μTAS system. Limit of detection of S2,3PSA was 0.05 ng/mL and coefficient variation was less than 3.1%. The area under the curve (AUC) for detection of PCa for the S2,3PSA ratio (%S2,3PSA) with cutoff value 43.85% (AUC; 0.8340) was much superior to total PSA (AUC; 0.5062) using validation sample set. Although the present results are preliminary, the newly developed μTAS platform for measuring %S2,3PSA can achieve the required assay performance specifications for use in the practical and clinical setting and may improve the accuracy of PCa diagnosis. Additional validation studies are warranted. PMID:28241428
ICS-II USA research design and methodology.
Rana, H; Andersen, R M; Nakazono, T T; Davidson, P L
1997-05-01
The purpose of the WHO-sponsored International Collaborative Study of Oral Health Outcomes (ICS-II) was to provide policy-markers and researchers with detailed, reliable, and valid data on the oral health situation in their countries or regions, together with comparative data from other dental care delivery systems. ICS-II used a cross-sectional design with no explicit control groups or experimental interventions. A standardized methodology was developed and tested for collecting and analyzing epidemiological, sociocultural, economic, and delivery system data. Respondent information was obtained by household interviews, and clinical examinations were conducted by calibrated oral epidemiologists. Discussed are the sampling design characteristics for the USA research locations, response rates, samples size for interview and oral examination data, weighting procedures, and statistical methods. SUDAAN was used to adjust variance calculations, since complex sampling designs were used.
Blood oxygen saturation of frozen tissue determined by hyper spectral imaging
NASA Astrophysics Data System (ADS)
Braaf, Boy; Nadort, Annemarie; Faber, Dirk; ter Wee, Rene; van Leeuwen, Ton; Aalders, Maurice
2008-02-01
A method is proposed for determining blood oxygen saturation in frozen tissue. The method is based on a spectral camera system equipped with an Acoustic-Optical-Tuneable-Filter. The HSI-setup is validated by measuring series of unfrozen and frozen samples of a hemoglobin-solution, a hemoglobin-intralipid mixture and whole blood with varying oxygen saturation. The theoretically predicted linear relation between oxygen saturation and absorbance was observed in both the frozen sample series and the unfrozen series. In a final proof of principal, frozen myocardial tissue was measured. Higher saturation values were recorded for ventricle and atria tissue compared to the septum and connective tissue. These results are not validated by measurements with another method. The formation of methemoglobin during freezing and the presence of myoglobin in the tissue turned out to be possible sources of error.
2013-11-27
SECURITY CLASSIFICATION OF: CUBRC has developed an in-line, multi-analyte isolation technology that utilizes solid phase extraction chemistries to purify...goals. Specifically, CUBRC will design and manufacture a prototype cartridge(s) and test the prototype cartridge for its ability to isolate each...display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. CUBRC , Inc. P. O. Box 400 Buffalo, NY 14225 -1955
Development of a Thermal Wave Interferometry System for Thin-Film Characterisation
2012-10-01
describes a condition where the properties of the interface influence the phase and amplitude of the temperature oscillations at the surface. In the...The measured phase profiles are shown in Figure 13. Overall, the phase variation across the sample is significant, with a strong discontinuity in phase ...d eg ) 91.2 Hz 30 Hz 7 Hz 4 Hz Figure 13: Phase measurements across the coated sample. L1 L2 L3 L4 L5 A more rigorous validation of the
Wave transmission approach based on modal analysis for embedded mechanical systems
NASA Astrophysics Data System (ADS)
Cretu, Nicolae; Nita, Gelu; Ioan Pop, Mihail
2013-09-01
An experimental method for determining the phase velocity in small solid samples is proposed. The method is based on measuring the resonant frequencies of a binary or ternary solid elastic system comprising the small sample of interest and a gauge material of manageable size. The wave transmission matrix of the combined system is derived and the theoretical values of its eigenvalues are used to determine the expected eigenfrequencies that, equated with the measured values, allow for the numerical estimation of the phase velocities in both materials. The known phase velocity of the gauge material is then used to asses the accuracy of the method. Using computer simulation and the experimental values for phase velocities, the theoretical values for the eigenfrequencies of the eigenmodes of the embedded elastic system are obtained, to validate the method. We conclude that the proposed experimental method may be reliably used to determine the elastic properties of small solid samples whose geometries do not allow a direct measurement of their resonant frequencies.
NASA Astrophysics Data System (ADS)
Shen, Lin; Xie, Liangxu; Yang, Mingjun
2017-04-01
Conformational sampling under rugged energy landscape is always a challenge in computer simulations. The recently developed integrated tempering sampling, together with its selective variant (SITS), emerges to be a powerful tool in exploring the free energy landscape or functional motions of various systems. The estimation of weighting factors constitutes a critical step in these methods and requires accurate calculation of partition function ratio between different thermodynamic states. In this work, we propose a new adaptive update algorithm to compute the weighting factors based on the weighted histogram analysis method (WHAM). The adaptive-WHAM algorithm with SITS is then applied to study the thermodynamic properties of several representative peptide systems solvated in an explicit water box. The performance of the new algorithm is validated in simulations of these solvated peptide systems. We anticipate more applications of this coupled optimisation and production algorithm to other complicated systems such as the biochemical reactions in solution.
Rittirsch, Daniel; Schoenborn, Veit; Lindig, Sandro; Wanner, Elisabeth; Sprengel, Kai; Günkel, Sebastian; Blaess, Markus; Schaarschmidt, Barbara; Sailer, Patricia; Märsmann, Sonja; Simmen, Hans-Peter; Cinelli, Paolo; Bauer, Michael; Claus, Ralf A; Wanner, Guido A
2016-12-01
The present study was aimed to identify mechanisms linked to complicated courses and adverse events after severe trauma by a systems biology approach. In severe trauma, overwhelming systemic inflammation can result in additional damage and the development of complications, including sepsis. In a prospective, longitudinal single-center study, RNA samples from circulating leukocytes from patients with multiple injury (injury severity score ≥17 points; n = 81) were analyzed for dynamic changes in gene expression over a period of 21 days by whole-genome screening (discovery set; n = 10 patients; 90 samples) and quantitative RT-PCR (validation set; n = 71 patients, 517 samples). Multivariate correlational analysis of transcripts and clinical parameters was used to identify mechanisms related to sepsis. Transcriptome profiling of the discovery set revealed the strongest changes between patients with either systemic inflammation or sepsis in gene expression of the heme degradation pathway. Using quantitative RT-PCR analyses (validation set), the key components haptoglobin (HP), cluster of differentiation (CD) 163, heme oxygenase-1 (HMOX1), and biliverdin reductase A (BLVRA) showed robust changes following trauma. Upregulation of HP was associated with the severity of systemic inflammation and the development of sepsis. Patients who received allogeneic blood transfusions had a higher incidence of nosocomial infections and sepsis, and the amount of blood transfusion as source of free heme correlated with the expression pattern of HP. These findings indicate that the heme degradation pathway is associated with increased susceptibility to septic complications after trauma, which is indicated by HP expression in particular.
Hwang, Hee Sang; Yoon, Dok Hyun; Suh, Cheolwon; Huh, Jooryung
2016-08-01
Extranodal involvement is a well-known prognostic factor in patients with diffuse large B-cell lymphomas (DLBCL). Nevertheless, the prognostic impact of the extranodal scoring system included in the conventional international prognostic index (IPI) has been questioned in an era where rituximab treatment has become widespread. We investigated the prognostic impacts of individual sites of extranodal involvement in 761 patients with DLBCL who received rituximab-based chemoimmunotherapy. Subsequently, we established a new extranodal scoring system based on extranodal sites, showing significant prognostic correlation, and compared this system with conventional scoring systems, such as the IPI and the National Comprehensive Cancer Network-IPI (NCCN-IPI). An internal validation procedure, using bootstrapped samples, was also performed for both univariate and multivariate models. Using multivariate analysis with a backward variable selection, we found nine extranodal sites (the liver, lung, spleen, central nervous system, bone marrow, kidney, skin, adrenal glands, and peritoneum) that remained significant for use in the final model. Our newly established extranodal scoring system, based on these sites, was better correlated with patient survival than standard scoring systems, such as the IPI and the NCCN-IPI. Internal validation by bootstrapping demonstrated an improvement in model performance of our modified extranodal scoring system. Our new extranodal scoring system, based on the prognostically relevant sites, may improve the performance of conventional prognostic models of DLBCL in the rituximab era and warrants further external validation using large study populations.
Mining the human urine proteome for monitoring renal transplant injury
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sigdel, Tara K.; Gao, Yuqian; He, Jintang
The human urinary proteome reflects systemic and inherent renal injury perturbations and can be analyzed to harness specific biomarkers for different kidney transplant injury states. 396 unique urine samples were collected contemporaneously with an allograft biopsy from 396 unique kidney transplant recipients. Centralized, blinded histology on the graft was used to classify matched urine samples into categories of acute rejection (AR), chronic allograft nephropathy (CAN), BK virus nephritis (BKVN), and stable graft (STA). Liquid chromatography–mass spectrometry (LC-MS) based proteomics using iTRAQ based discovery (n=108) and global label-free LC-MS analyses of individual samples (n=137) for quantitative proteome assessment were used inmore » the discovery step. Selected reaction monitoring (SRM) was applied to identify and validate minimal urine protein/peptide biomarkers to accurately segregate organ injury causation and pathology on unique urine samples (n=151). A total of 958 proteins were initially quantified by iTRAQ, 87% of which were also identified among 1574 urine proteins detected in LC-MS validation. 103 urine proteins were significantly (p<0.05) perturbed in injury and enriched for humoral immunity, complement activation, and lymphocyte trafficking. A set of 131 peptides corresponding to 78 proteins were assessed by SRM for their significance in an independent sample cohort. A minimal set of 35 peptides mapping to 33 proteins, were modeled to segregate different injury groups (AUC =93% for AR, 99% for CAN, 83% for BKVN). Urinary proteome discovery and targeted validation identified urine protein fingerprints for non-invasive differentiation of kidney transplant injuries, thus opening the door for personalized immune risk assessment and therapy.« less
A Comparison of Screening Instruments: Predictive Validity of the BESS and BSC
ERIC Educational Resources Information Center
King, Kathleen R.; Reschly, Amy L.
2014-01-01
The purpose of this study was to evaluate and compare two behavior screening instruments--the Behavioral and Emotional Screening System and the Behavior Screening Checklist. The sample consisted of 492 elementary school children from the southeastern United States. The psychometric properties of the screening instruments were evaluated in terms of…
Krypton and xenon in lunar fines
NASA Technical Reports Server (NTRS)
Basford, J. R.; Dragon, J. C.; Pepin, R. O.; Coscio, M. R., Jr.; Murthy, V. R.
1973-01-01
Data from grain-size separates, stepwise-heated fractions, and bulk analyses of 20 samples of fines and breccias from five lunar sites are used to define three-isotope and ordinate intercept correlations in an attempt to resolve the lunar heavy rare gas system in a statistically valid approach. Tables of concentrations and isotope compositions are given.
National visitor use monitoring implementation in Alaska.
Eric M. White; Joshua B. Wilson
2008-01-01
The USDA Forest Service implemented the National Visitor Use Monitoring (NVUM) program across the entire National Forest System (NFS) in calendar year 2000. The primary objective of the NVUM program is to develop reliable estimates of recreation use on NFS lands via a nationally consistent, statistically valid sampling approach. Secondary objectives of NVUM are to...
Hirdes, John P; Poss, Jeff W; Curtin-Telegdi, Nancy
2008-01-01
Background Home care plays a vital role in many health care systems, but there is evidence that appropriate targeting strategies must be used to allocate limited home care resources effectively. The aim of the present study was to develop and validate a methodology for prioritizing access to community and facility-based services for home care clients. Methods Canadian and international data based on the Resident Assessment Instrument – Home Care (RAI-HC) were analyzed to identify predictors for nursing home placement, caregiver distress and for being rated as requiring alternative placement to improve outlook. Results The Method for Assigning Priority Levels (MAPLe) algorithm was a strong predictor of all three outcomes in the derivation sample. The algorithm was validated with additional data from five other countries, three other provinces, and an Ontario sample obtained after the use of the RAI-HC was mandated. Conclusion The MAPLe algorithm provides a psychometrically sound decision-support tool that may be used to inform choices related to allocation of home care resources and prioritization of clients needing community or facility-based services. PMID:18366782
Trotta, Michele; Schönhuth, Susana; Pepe, Tiziana; Cortesi, M Luisa; Puyet, Antonio; Bautista, José M
2005-03-23
Mitochondrial 16S rRNA sequences from morphological validated grouper (Epinephelus aeneus, E. caninus, E. costae, and E. marginatus; Mycteroperca fusca and M. rubra), Nile perch (Lates niloticus), and wreck fish (Polyprion americanus) were used to develop an analytical system for group diagnosis based on two alternative Polymerase Chain Reaction (PCR) approaches. The first includes conventional multiplex PCR in which electrophoretic migration of different sizes of bands allowed identification of the fish species. The second approach, involving real-time PCR, produced a single amplicon from each species that showed different Tm values allowing the fish groups to be directly identified. Real-time PCR allows the quick differential diagnosis of the three groups of species and high-throughput screening of multiple samples. Neither PCR system cross-reacted with DNA samples from 41 common marketed fish species, thus conforming to standards for species validation. The use of these two PCR-based methods makes it now possible to discriminate grouper from substitute fish species.
Montgomery, Eric; Gao, Chen; de Luca, Julie; Bower, Jessie; Attwood, Kristropher; Ylagan, Lourdes
2014-12-01
The Cellient(®) cell block system has become available as an alternative, partially automated method to create cell blocks in cytology. We sought to show a validation method for immunohistochemical (IHC) staining on the Cellient cell block system (CCB) in comparison with the formalin fixed paraffin embedded traditional cell block (TCB). Immunohistochemical staining was performed using 31 antibodies on 38 patient samples for a total of 326 slides. Split samples were processed using both methods by following the Cellient(®) manufacturer's recommendations for the Cellient cell block (CCB) and the Histogel method for preparing the traditional cell block (TCB). Interpretation was performed by three pathologists and two cytotechnologists. Immunohistochemical stains were scored as: 0/1+ (negative) and 2/3+ (positive). Inter-rater agreement for each antibody was evaluated for CCB and TCB, as well as the intra-rater agreement between TCB and CCB between observers. Interobserver staining concordance for the TCB was obtained with statistical significance (P < 0.05) in 24 of 31 antibodies. Interobserver staining concordance for the CCB was obtained with statistical significance in 27 of 31 antibodies. Intra-observer staining concordance between TCB and CCB was obtained with statistical significance in 24 of 31 antibodies tested. In conclusions, immunohistochemical stains on cytologic specimens processed by the Cellient system are reliable and concordant with stains performed on the same split samples processed via a formalin fixed-paraffin embedded (FFPE) block. The Cellient system is a welcome adjunct to cytology work-flow by producing cell block material of sufficient quality to allow the use of routine IHC. © 2014 Wiley Periodicals, Inc.
Lavoie, Jacques; Marchand, Geneviève; Cloutier, Yves; Lavoué, Jérôme
2011-08-01
Dust accumulation in the components of heating, ventilation, and air-conditioning (HVAC) systems is a potential source of contaminants. To date, very little information is available on recognized methods for assessing dust buildup in these systems. The few existing methods are either objective in nature, involving numerical values, or subjective in nature, based on experts' judgments. An earlier project aimed at assessing different methods of sampling dust in ducts was carried out in the laboratories of the Institut de recherche Robert-Sauvé en santé et en sécurité du travail (IRSST). This laboratory study showed that all the sampling methods were practicable, provided that a specific surface-dust cleaning initiation criterion was used for each method. However, these conclusions were reached on the basis of ideal conditions in a laboratory using a reference dust. The objective of this present study was to validate these laboratory results in the field. To this end, the laboratory sampling templates were replicated in real ducts and the three sampling methods (the IRSST method, the method of the U.S. organization National Air Duct Cleaner Association [NADCA] and that of the French organization Association pour la Prévention et l'Étude de la Contamination [ASPEC]) were used simultaneously in a statistically representative number of systems. The air return and supply ducts were also compared. Cleaning initiation criteria under real conditions were found to be 6.0 mg/100 cm(2) using the IRSST method, 2.0 mg/100 cm(2) using the NADCA method, and 23 mg/100 cm(2) using the ASPEC method. In the laboratory study, the criteria using the same methods were 6.0 for the IRSST method, 2.0 for the NADCA method, and 3.0 for the ASPEC method. The laboratory criteria for the IRSST and NADCA methods were therefore validated in the field. The ASPEC criterion was the only one to change. The ASPEC method therefore allows for the most accurate evaluation of dust accumulation in HVAC ductwork. We therefore recommend using the latter method to objectively assess dust accumulation levels in HVAC ductwork.
Song, Jungeun; Leventhal, Bennett L.; Koh, Yun-Joo; Cheon, Keun-Ah; Hong, Hyun Ju; Kim, Young-Key; Cho, Kyungjin; Lim, Eun-Chung; Park, Jee In
2017-01-01
Purpose Our study aimed to examine psychometric properties and cross-cultural utility of the Behavior Assessment System for Children-2, Parent Rating Scale-Child (BASC-2 PRS-C) in Korean children. Materials and Methods Two study populations were recruited: a general population sample (n=2115) of 1st to 6th graders from 16 elementary schools and a clinical population (n=219) of 6–12 years old from 5 child psychiatric clinics and an epidemiological sample of autism spectrum disorder. We assessed the validity and reliability of the Korean version of BASC-2 PRS-C (K-BASC-2 PRS-C) and compared subscales with those used for US populations. Results Our results indicate that the K-BASC-2 PRS-C is a valuable instrument with reliability and validity for measuring developmental psychopathology that is comparable to those in Western population. However, there were some differences noted in the mean scores of BASC-2 PRS-C between Korean and US populations. Conclusion K-BASC-2 PRS-C is an effective and useful instrument with psychometric properties that permits measurement of general developmental psychopathology. Observed Korean-US differences in patterns of parental reports of children's behaviors indicate the importance of the validation, standardization and cultural adaptation for tools assessing psychopathology especially when used in populations different from those for which the instrument was originally created. PMID:28120577
Song, Jungeun; Leventhal, Bennett L; Koh, Yun Joo; Cheon, Keun Ah; Hong, Hyun Ju; Kim, Young Key; Cho, Kyungjin; Lim, Eun Chung; Park, Jee In; Kim, Young Shin
2017-03-01
Our study aimed to examine psychometric properties and cross-cultural utility of the Behavior Assessment System for Children-2, Parent Rating Scale-Child (BASC-2 PRS-C) in Korean children. Two study populations were recruited: a general population sample (n=2115) of 1st to 6th graders from 16 elementary schools and a clinical population (n=219) of 6-12 years old from 5 child psychiatric clinics and an epidemiological sample of autism spectrum disorder. We assessed the validity and reliability of the Korean version of BASC-2 PRS-C (K-BASC-2 PRS-C) and compared subscales with those used for US populations. Our results indicate that the K-BASC-2 PRS-C is a valuable instrument with reliability and validity for measuring developmental psychopathology that is comparable to those in Western population. However, there were some differences noted in the mean scores of BASC-2 PRS-C between Korean and US populations. K-BASC-2 PRS-C is an effective and useful instrument with psychometric properties that permits measurement of general developmental psychopathology. Observed Korean-US differences in patterns of parental reports of children's behaviors indicate the importance of the validation, standardization and cultural adaptation for tools assessing psychopathology especially when used in populations different from those for which the instrument was originally created.
Interpreting MAD within multiple accretion regimes
NASA Astrophysics Data System (ADS)
Mocz, Philip; Guo, Xinyi
2015-02-01
General relativistic magnetohydrodynamic (GRMHD) simulations of accreting black holes in the radiatively inefficient regime show that systems with sufficient magnetic poloidal flux become magnetically arrested disc (MAD) systems, with a well-defined relationship between the magnetic flux and the mass accretion rate. Recently, Zamaninasab et al. report that the jet magnetic flux and accretion disc luminosity are tightly correlated over 7 orders of magnitude for a sample of 76 radio-loud active galaxies, concluding that the data are explained by the MAD mode of accretion. Their analysis assumes radiatively efficient accretion, and their sample consists primarily of radiatively efficient sources, while GRMHD simulations of MAD thus far have been carried out in the radiatively inefficient regime. We propose a model to interpret MAD systems in the context of multiple accretion regimes, and apply it to the sample in Zamaninasab et al., along with additional radiatively inefficient sources from archival data. We show that most of the radiatively inefficient radio-loud galaxies are consistent with being MAD systems. Assuming the MAD relationship found in radiatively inefficient simulations holds at other accretion regimes, a significant fraction of our sample can be candidates for MAD systems. Future GRMHD simulations have yet to verify the validity of this assumption.
Wygant, Dustin B; Ben-Porath, Yossef S; Arbisi, Paul A; Berry, David T R; Freeman, David B; Heilbronner, Robert L
2009-11-01
The current study examined the effectiveness of the MMPI-2 Restructured Form (MMPI-2-RF; Ben-Porath and Tellegen, 2008) over-reporting indicators in civil forensic settings. The MMPI-2-RF includes three revised MMPI-2 over-reporting validity scales and a new scale to detect over-reported somatic complaints. Participants dissimulated medical and neuropsychological complaints in two simulation samples, and a known-groups sample used symptom validity tests as a response bias criterion. Results indicated large effect sizes for the MMPI-2-RF validity scales, including a Cohen's d of .90 for Fs in a head injury simulation sample, 2.31 for FBS-r, 2.01 for F-r, and 1.97 for Fs in a medical simulation sample, and 1.45 for FBS-r and 1.30 for F-r in identifying poor effort on SVTs. Classification results indicated good sensitivity and specificity for the scales across the samples. This study indicates that the MMPI-2-RF over-reporting validity scales are effective at detecting symptom over-reporting in civil forensic settings.
Wallace, F Morgan; DiCosimo, Deana; Farnum, Andrew; Tice, George; Andaloro, Bridget; Davis, Eugene; Burns, Frank R
2011-01-01
In 2010, the BAX System PCR assay for Salmonella was modified to include a hot start functionality designed to keep the reaction enzyme inactive until PCR begins. To validate the assay's Official Methods of Analysis status to include this procedure modification, an evaluation was conducted on four food types that were simultaneously analyzed with the BAX System and either the U.S. Food and Drug Administration's Bacteriological Analytical Manual or the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook reference method for detecting Salmonella. Identical performance between the BAX System method and the reference methods was observed. Additionally, lysates were analyzed using both the BAX System Classic and BAX System Q7 instruments with identical results using both platforms for all samples tested. Of the 100 samples analyzed, 34 samples were positive for both the BAX System and reference methods, and 66 samples were negative by both the BAX System and reference methods, demonstrating 100% correlation. No instrument platform variation was observed. Additional inclusivity and exclusivity testing using the modified test kit demonstrated the test kit to be 100% accurate in evaluation of test panels of 352 Salmonella strains and 46 non-Salmonella strains.
NASA Astrophysics Data System (ADS)
Morton, Timothy D.; Bryson, Stephen T.; Coughlin, Jeffrey L.; Rowe, Jason F.; Ravichandran, Ganesh; Petigura, Erik A.; Haas, Michael R.; Batalha, Natalie M.
2016-05-01
We present astrophysical false positive probability calculations for every Kepler Object of Interest (KOI)—the first large-scale demonstration of a fully automated transiting planet validation procedure. Out of 7056 KOIs, we determine that 1935 have probabilities <1% of being astrophysical false positives, and thus may be considered validated planets. Of these, 1284 have not yet been validated or confirmed by other methods. In addition, we identify 428 KOIs that are likely to be false positives, but have not yet been identified as such, though some of these may be a result of unidentified transit timing variations. A side product of these calculations is full stellar property posterior samplings for every host star, modeled as single, binary, and triple systems. These calculations use vespa, a publicly available Python package that is able to be easily applied to any transiting exoplanet candidate.
Karanikola, Maria N K; Papathanassoglou, Elizabeth D E
2015-02-01
The Index of Work Satisfaction (IWS) is a comprehensive scale assessing nurses' professional satisfaction. The aim of the present study was to explore: a) the applicability, reliability and validity of the Greek version of the IWS and b) contrasts among the factors addressed by IWS against the main themes emerging from a qualitative phenomenological investigation of nurses' professional experiences. A descriptive correlational design was applied using a sample of 246 emergency and critical care nurses. Internal consistency and test-retest reliability were tested. Construct and content validity were assessed by factor analysis, and through qualitative phenomenological analysis with a purposive sample of 12 nurses. Scale factors were contrasted to qualitative themes to assure that IWS embraces all aspects of Greek nurses' professional satisfaction. The internal consistency (α = 0.81) and test-retest (tau = 1, p < 0.0001) reliability were adequate. Following appropriate modifications, factor analysis confirmed the construct validity of the scale and subscales. The qualitative data partially clarified the low reliability of one subscale. The Greek version of the IWS scale is supported for use in acute care. The mixed methods approach constitutes a powerful tool for transferring scales to different cultures and healthcare systems. Copyright © 2014 Elsevier Inc. All rights reserved.
Frégeau, Chantal J; Lett, C Marc; Fourney, Ron M
2010-10-01
A semi-automated DNA extraction process for casework samples based on the Promega DNA IQ™ system was optimized and validated on TECAN Genesis 150/8 and Freedom EVO robotic liquid handling stations configured with fixed tips and a TECAN TE-Shake™ unit. The use of an orbital shaker during the extraction process promoted efficiency with respect to DNA capture, magnetic bead/DNA complex washes and DNA elution. Validation studies determined the reliability and limitations of this shaker-based process. Reproducibility with regards to DNA yields for the tested robotic workstations proved to be excellent and not significantly different than that offered by the manual phenol/chloroform extraction. DNA extraction of animal:human blood mixtures contaminated with soil demonstrated that a human profile was detectable even in the presence of abundant animal blood. For exhibits containing small amounts of biological material, concordance studies confirmed that DNA yields for this shaker-based extraction process are equivalent or greater to those observed with phenol/chloroform extraction as well as our original validated automated magnetic bead percolation-based extraction process. Our data further supports the increasing use of robotics for the processing of casework samples. Crown Copyright © 2009. Published by Elsevier Ireland Ltd. All rights reserved.
Serious injury prediction algorithm based on large-scale data and under-triage control.
Nishimoto, Tetsuya; Mukaigawa, Kosuke; Tominaga, Shigeru; Lubbe, Nils; Kiuchi, Toru; Motomura, Tomokazu; Matsumoto, Hisashi
2017-01-01
The present study was undertaken to construct an algorithm for an advanced automatic collision notification system based on national traffic accident data compiled by Japanese police. While US research into the development of a serious-injury prediction algorithm is based on a logistic regression algorithm using the National Automotive Sampling System/Crashworthiness Data System, the present injury prediction algorithm was based on comprehensive police data covering all accidents that occurred across Japan. The particular focus of this research is to improve the rescue of injured vehicle occupants in traffic accidents, and the present algorithm assumes the use of an onboard event data recorder data from which risk factors such as pseudo delta-V, vehicle impact location, seatbelt wearing or non-wearing, involvement in a single impact or multiple impact crash and the occupant's age can be derived. As a result, a simple and handy algorithm suited for onboard vehicle installation was constructed from a sample of half of the available police data. The other half of the police data was applied to the validation testing of this new algorithm using receiver operating characteristic analysis. An additional validation was conducted using in-depth investigation of accident injuries in collaboration with prospective host emergency care institutes. The validated algorithm, named the TOYOTA-Nihon University algorithm, proved to be as useful as the US URGENCY and other existing algorithms. Furthermore, an under-triage control analysis found that the present algorithm could achieve an under-triage rate of less than 10% by setting a threshold of 8.3%. Copyright © 2016 Elsevier Ltd. All rights reserved.
Triantis, Theodoros; Tsimeli, Katerina; Kaloudis, Triantafyllos; Thanassoulias, Nicholas; Lytras, Efthymios; Hiskia, Anastasia
2010-05-01
A system of analytical processes has been developed in order to serve as a cost-effective scheme for the monitoring of cyanobacterial toxins on a quantitative basis, in surface and drinking waters. Five cyclic peptide hepatotoxins, microcystin-LR, -RR, -YR, -LA and nodularin were chosen as the target compounds. Two different enzyme-linked immunosorbent assays (ELISA) were validated in order to serve as primary quantitative screening tools. Validation results showed that the ELISA methods are sufficiently specific and sensitive with limits of detection (LODs) around 0.1 microg/L, however, matrix effects should be considered, especially with surface water samples or bacterial mass methanolic extracts. A colorimetric protein phosphatase inhibition assay (PPIA) utilizing protein phosphatase 2A and p-nitrophenyl phosphate as substrate, was applied in microplate format in order to serve as a quantitative screening method for the detection of the toxic activity associated with cyclic peptide hepatotoxins, at concentration levels >0.2 microg/L of MC-LR equivalents. A fast HPLC/PDA method has been developed for the determination of microcystins, by using a short, 50mm C18 column, with 1.8 microm particle size. Using this method a 10-fold reduction of sample run time was achieved and sufficient separation of microcystins was accomplished in less than 3 min. Finally, the analytical system includes an LC/MS/MS method that was developed for the determination of the 5 target compounds after SPE extraction. The method achieves extremely low limits of detection (<0.02 microg/L), in both surface and drinking waters and it is used for identification and verification purposes as well as for determinations at the ppt level. An analytical protocol that includes the above methods has been designed and validated through the analysis of a number of real samples. Copyright 2009 Elsevier Ltd. All rights reserved.
Where do the Field Plots Belong? A Multiple-Constraint Sampling Design for the BigFoot Project
NASA Astrophysics Data System (ADS)
Kennedy, R. E.; Cohen, W. B.; Kirschbaum, A. A.; Gower, S. T.
2002-12-01
A key component of a MODIS validation project is effective characterization of biophysical measures on the ground. Fine-grain ecological field measurements must be placed strategically to capture variability at the scale of the MODIS imagery. Here we describe the BigFoot project's revised sampling scheme, designed to simultaneously meet three important goals: capture landscape variability, avoid spatial autocorrelation between field plots, and minimize time and expense of field sampling. A stochastic process places plots in clumped constellations to reduce field sampling costs, while minimizing spatial autocorrelation. This stochastic process is repeated, creating several hundred realizations of plot constellations. Each constellation is scored and ranked according to its ability to match landscape variability in several Landsat-based spectral indices, and its ability to minimize field sampling costs. We show how this approach has recently been used to place sample plots at the BigFoot project's two newest study areas, one in a desert system and one in a tundra system. We also contrast this sampling approach to that already used at the four prior BigFoot project sites.
Nowak, Sascha; Gesell, Monika; Holtkamp, Michael; Scheffer, Andy; Sperling, Michael; Karst, Uwe; Buscher, Wolfgang
2014-11-01
In this work, the recently introduced low flow inductively coupled plasma optical emission spectrometry (ICP-OES) with a total argon consumption below 0.7 L/min is applied for the first time to the field of food analysis. One goal is the investigation of the performance of this low flow plasma compared to a conventional ICP-OES system when non-aqueous samples with a certain matrix are introduced into the system. For this purpose, arsenic is determined in three different kinds of fish samples. In addition several nutrients (K, Na, Mg, Ca) and trace metals (Co, Cu, Mn, Cd, Pb, Zn, Fe, and Ni) are determined in honey samples (acacia) after microwave digestion. The precision of the measurements is characterized by relative standard deviations (RSD) and compared to the corresponding precision values achieved using the conventional Fassel-type torch of the ICP. To prove the accuracy of the low flow ICP-OES method, the obtained data from honey samples are validated by a conventional ICP-OES. For the measurements concerning arsenic in fish, the low flow ICP-OES values are validated by conventional Fassel-type ICP-OES. Furthermore, a certified reference material was investigated with the low gas flow setup. Limits of detection (LOD), according to the 3σ criterion, were determined to be in the low microgram per liter range for all analytes. Recovery rates in the range of 96-106% were observed for the determined trace metal elements. It was proven that the low gas flow ICP-OES leads to results that are comparable with those obtained with the Fassel-type torch for the analysis of food samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Development of the Systems Thinking Scale for Adolescent Behavior Change.
Moore, Shirley M; Komton, Vilailert; Adegbite-Adeniyi, Clara; Dolansky, Mary A; Hardin, Heather K; Borawski, Elaine A
2018-03-01
This report describes the development and psychometric testing of the Systems Thinking Scale for Adolescent Behavior Change (STS-AB). Following item development, initial assessments of understandability and stability of the STS-AB were conducted in a sample of nine adolescents enrolled in a weight management program. Exploratory factor analysis of the 16-item STS-AB and internal consistency assessments were then done with 359 adolescents enrolled in a weight management program. Test-retest reliability of the STS-AB was .71, p = .03; internal consistency reliability was .87. Factor analysis of the 16-item STS-AB indicated a one-factor solution with good factor loadings, ranging from .40 to .67. Evidence of construct validity was supported by significant correlations with established measures of variables associated with health behavior change. We provide beginning evidence of the reliability and validity of the STS-AB to measure systems thinking for health behavior change in young adolescents.
Development of the Systems Thinking Scale for Adolescent Behavior Change
Moore, Shirley M.; Komton, Vilailert; Adegbite-Adeniyi, Clara; Dolansky, Mary A.; Hardin, Heather K.; Borawski, Elaine A.
2017-01-01
This report describes the development and psychometric testing of the Systems Thinking Scale for Adolescent Behavior Change (STS-AB). Following item development, initial assessments of understandability and stability of the STS-AB were conducted in a sample of nine adolescents enrolled in a weight management program. Exploratory factor analysis of the 16-item STS-AB and internal consistency assessments were then done with 359 adolescents enrolled in a weight management program. Test–retest reliability of the STS-AB was .71, p = .03; internal consistency reliability was .87. Factor analysis of the 16-item STS-AB indicated a one-factor solution with good factor loadings, ranging from .40 to .67. Evidence of construct validity was supported by significant correlations with established measures of variables associated with health behavior change. We provide beginning evidence of the reliability and validity of the STS-AB to measure systems thinking for health behavior change in young adolescents. PMID:28303755
Boerebach, Benjamin C M; Lombarts, Kiki M J M H; Arah, Onyebuchi A
2016-03-01
The System for Evaluation of Teaching Qualities (SETQ) was developed as a formative system for the continuous evaluation and development of physicians' teaching performance in graduate medical training. It has been seven years since the introduction and initial exploratory psychometric analysis of the SETQ questionnaires. This study investigates the validity and reliability of the SETQ questionnaires across hospitals and medical specialties using confirmatory factor analyses (CFAs), reliability analysis, and generalizability analysis. The SETQ questionnaires were tested in a sample of 3,025 physicians and 2,848 trainees in 46 hospitals. The CFA revealed acceptable fit of the data to the previously identified five-factor model. The high internal consistency estimates suggest satisfactory reliability of the subscales. These results provide robust evidence for the validity and reliability of the SETQ questionnaires for evaluating physicians' teaching performance. © The Author(s) 2014.
Beno, Sarah M; Stasiewicz, Matthew J; Andrus, Alexis D; Ralyea, Robert D; Kent, David J; Martin, Nicole H; Wiedmann, Martin; Boor, Kathryn J
2016-12-01
Pathogen environmental monitoring programs (EMPs) are essential for food processing facilities of all sizes that produce ready-to-eat food products exposed to the processing environment. We developed, implemented, and evaluated EMPs targeting Listeria spp. and Salmonella in nine small cheese processing facilities, including seven farmstead facilities. Individual EMPs with monthly sample collection protocols were designed specifically for each facility. Salmonella was detected in only one facility, with likely introduction from the adjacent farm indicated by pulsed-field gel electrophoresis data. Listeria spp. were isolated from all nine facilities during routine sampling. The overall Listeria spp. (other than Listeria monocytogenes ) and L. monocytogenes prevalences in the 4,430 environmental samples collected were 6.03 and 1.35%, respectively. Molecular characterization and subtyping data suggested persistence of a given Listeria spp. strain in seven facilities and persistence of L. monocytogenes in four facilities. To assess routine sampling plans, validation sampling for Listeria spp. was performed in seven facilities after at least 6 months of routine sampling. This validation sampling was performed by independent individuals and included collection of 50 to 150 samples per facility, based on statistical sample size calculations. Two of the facilities had a significantly higher frequency of detection of Listeria spp. during the validation sampling than during routine sampling, whereas two other facilities had significantly lower frequencies of detection. This study provides a model for a science- and statistics-based approach to developing and validating pathogen EMPs.
Matson, Pamela A; Towe, Vivian; Ellen, Jonathan M; Chung, Shang-En; Sherman, Susan G
2018-03-01
Young men who have been involved with the criminal justice system are more likely to have concurrent sexual partners, a key driver of sexually transmitted infections. The value men place on having sexual relationships to validate themselves may play an important role in understanding this association. Data were from a household survey. Young men (N = 132), aged 16 to 24 years, self-reported whether they ever spent time in jail or juvenile detention and if they had sexual partnerships that overlapped in time. A novel scale, "Validation through Sex and Sexual Relationships" (VTSSR) assessed the importance young men place on sex and sexual relationships (α = 0.91). Weighted logistic regression accounted for the sampling design. The mean (SD) VTSSR score was 23.7 (8.8) with no differences by race. Both criminal justice involvement (CJI) (odds ratio [OR], 3.69; 95% confidence interval [CI], 1.12-12.1) and sexual validation (OR, 1.10; 95% CI, 1.04-1.16) were associated with an increased odds of concurrency; however, CJI did not remain associated with concurrency in the fully adjusted model. There was effect modification, CJI was associated with concurrency among those who scored high on sexual validation (OR, 9.18; 95% CI, 1.73-48.6]; however, there was no association among those who scored low on sexual validation. Racial differences were observed between CJI and concurrency, but not between sexual validation and concurrency. Sexual validation may be an important driver of concurrency for men who have been involved with the criminal justice system. Study findings have important implications on how sexual validation may explain racial differences in rates of concurrency.
Lopes, Bianca Rebelo; Cassiano, Neila Maria; Carvalho, Daniela Miarelli; Moisés, Elaine Christine Dantas; Cass, Quezia Bezerra
2018-02-20
A two-dimensional liquid chromatography system coupled to triple quadrupole tandem mass spectrometer (2D LC-MS/MS) was employed for the determination of fluoxetine (FLU) and norfluoxetine (N-FLU) in colostrum and mature milk by direct sample injection. With a run time of 12 min representing a gain in throughput analysis, the validated methods furnished selectivity, extraction efficiency, accuracy, and precision in accordance with the criteria preconized by the European Medicines Agency guidelines. With a linear range of 3.00-150 ng/mL for FLU and 4.00-200 ng/mL for N-FLU they were applied to the analysis of colostrum and mature milk samples from nursing mothers. The paper discusses the differences and similarity of sample preparation for this two sample matrices. The herein reported methods are an advance in sample preparation procedures providing waste reduction and a sustainable approach. Copyright © 2017 Elsevier B.V. All rights reserved.
Design of Control Software for a High-Speed Coherent Doppler Lidar System for CO2 Measurement
NASA Technical Reports Server (NTRS)
Vanvalkenburg, Randal L.; Beyon, Jeffrey Y.; Koch, Grady J.; Yu, Jirong; Singh, Upendra N.; Kavaya, Michael J.
2010-01-01
The design of the software for a 2-micron coherent high-speed Doppler lidar system for CO2 measurement at NASA Langley Research Center is discussed in this paper. The specific strategy and design topology to meet the requirements of the system are reviewed. In order to attain the high-speed digitization of the different types of signals to be sampled on multiple channels, a carefully planned design of the control software is imperative. Samples of digitized data from each channel and their roles in data analysis post processing are also presented. Several challenges of extremely-fast, high volume data acquisition are discussed. The software must check the validity of each lidar return as well as other monitoring channel data in real-time. For such high-speed data acquisition systems, the software is a key component that enables the entire scope of CO2 measurement studies using commercially available system components.
ERIC Educational Resources Information Center
Maiano, Christophe; Begarie, Jerome; Morin, Alexandre J. S.; Garbarino, Jean-Marie; Ninot, Gregory
2010-01-01
The purpose of this study was to test the reliability (i.e. internal consistency and test-retest reliability) and construct validity (i.e. content validity, factor validity, measurement invariance, and latent mean invariance) of the Nutrition and Activity Knowledge Scale (NAKS) in a sample of French adolescents with mild to moderate Intellectual…
Chieng, Norman; Trnka, Hjalte; Boetker, Johan; Pikal, Michael; Rantanen, Jukka; Grohganz, Holger
2013-09-15
The purpose of this study is to investigate the use of multivariate data analysis for powder X-ray diffraction-pair-wise distribution function (PXRD-PDF) data to detect phase separation in freeze-dried binary amorphous systems. Polymer-polymer and polymer-sugar binary systems at various ratios were freeze-dried. All samples were analyzed by PXRD, transformed to PDF and analyzed by principal component analysis (PCA). These results were validated by differential scanning calorimetry (DSC) through characterization of glass transition of the maximally freeze-concentrate solute (Tg'). Analysis of PXRD-PDF data using PCA provides a more clear 'miscible' or 'phase separated' interpretation through the distribution pattern of samples on a score plot presentation compared to residual plot method. In a phase separated system, samples were found to be evenly distributed around the theoretical PDF profile. For systems that were miscible, a clear deviation of samples away from the theoretical PDF profile was observed. Moreover, PCA analysis allows simultaneous analysis of replicate samples. Comparatively, the phase behavior analysis from PXRD-PDF-PCA method was in agreement with the DSC results. Overall, the combined PXRD-PDF-PCA approach improves the clarity of the PXRD-PDF results and can be used as an alternative explorative data analytical tool in detecting phase separation in freeze-dried binary amorphous systems. Copyright © 2013 Elsevier B.V. All rights reserved.
Chang, Ching-Sheng; Chen, Su-Yueh; Lan, Yi-Ting
2012-11-21
No previous studies have addressed the integrated relationships among system quality, service quality, job satisfaction, and system performance; this study attempts to bridge such a gap with evidence-based practice study. The convenience sampling method was applied to the information system users of three hospitals in southern Taiwan. A total of 500 copies of questionnaires were distributed, and 283 returned copies were valid, suggesting a valid response rate of 56.6%. SPSS 17.0 and AMOS 17.0 (structural equation modeling) statistical software packages were used for data analysis and processing. The findings are as follows: System quality has a positive influence on service quality (γ11= 0.55), job satisfaction (γ21= 0.32), and system performance (γ31= 0.47). Service quality (β31= 0.38) and job satisfaction (β32= 0.46) will positively influence system performance. It is thus recommended that the information office of hospitals and developers take enhancement of service quality and user satisfaction into consideration in addition to placing b on system quality and information quality when designing, developing, or purchasing an information system, in order to improve benefits and gain more achievements generated by hospital information systems.
Measuring and Validating Neutron Capture Cross Sections Using a Lead Slowing-Down Spectrometer
NASA Astrophysics Data System (ADS)
Thompson, Nicholas
Accurate nuclear data is essential for the modeling, design, and operation of nuclear systems. In this work, the Rensselaer Polytechnic Institute (RPI) Lead Slowing-Down Spectrometer (LSDS) at the Gaerttner Linear Accelerator Center (LINAC) was used to measure neutron capture cross sections and validate capture cross sections in cross section libraries. The RPI LINAC was used to create a fast burst of neutrons in the center of the LSDS, a large cube of high purity lead. A sample and YAP:Ce scintillator were placed in the LSDS, and as neutrons lost energy through scattering interactions with the lead, the scintillator detected capture gammas resulting from neutron capture events in the sample. Samples of silver, gold, cobalt, iron, indium, molybdenum, niobium, nickel, tin, tantalum, and zirconium were measured. Data was collected as a function of time after neutron pulse, or slowing-down time, which is correlated to average neutron energy. An analog and a digital data acquisition system collected data simultaneously, allowing for collection of pulse shape information as well as timing. Collection of digital data allowed for pulse shape analysis after the experiment. This data was then analyzed and compared to Monte Carlo simulations to validate the accuracy of neutron capture cross section libraries. These measurements represent the first time that neutron capture cross sections have been measured using an LSDS in the United States, and the first time tools such as coincidence measurements and pulse height weighting have been applied to measurements of neutron capture cross sections using an LSDS. Significant differences between measurement results and simulation results were found in multiple materials, and some errors in nuclear data libraries have already been identified due to these measurements.
Jiang, Weiqin; Shen, Yifei; Ding, Yongfeng; Ye, Chuyu; Zheng, Yi; Zhao, Peng; Liu, Lulu; Tong, Zhou; Zhou, Linfu; Sun, Shuo; Zhang, Xingchen; Teng, Lisong; Timko, Michael P; Fan, Longjiang; Fang, Weijia
2018-01-15
Synchronous multifocal tumors are common in the hepatobiliary and pancreatic system but because of similarities in their histological features, oncologists have difficulty in identifying their precise tissue clonal origin through routine histopathological methods. To address this problem and assist in more precise diagnosis, we developed a computational approach for tissue origin diagnosis based on naive Bayes algorithm (TOD-Bayes) using ubiquitous RNA-Seq data. Massive tissue-specific RNA-Seq data sets were first obtained from The Cancer Genome Atlas (TCGA) and ∼1,000 feature genes were used to train and validate the TOD-Bayes algorithm. The accuracy of the model was >95% based on tenfold cross validation by the data from TCGA. A total of 18 clinical cancer samples (including six negative controls) with definitive tissue origin were subsequently used for external validation and 17 of the 18 samples were classified correctly in our study (94.4%). Furthermore, we included as cases studies seven tumor samples, taken from two individuals who suffered from synchronous multifocal tumors across tissues, where the efforts to make a definitive primary cancer diagnosis by traditional diagnostic methods had failed. Using our TOD-Bayes analysis, the two clinical test cases were successfully diagnosed as pancreatic cancer (PC) and cholangiocarcinoma (CC), respectively, in agreement with their clinical outcomes. Based on our findings, we believe that the TOD-Bayes algorithm is a powerful novel methodology to accurately identify the tissue origin of synchronous multifocal tumors of unknown primary cancers using RNA-Seq data and an important step toward more precision-based medicine in cancer diagnosis and treatment. © 2017 UICC.
Evaluation of the measles, mumps and rubella vaccination catch-up campaign in England in 2013.
Simone, Benedetto; Balasegaram, Sooria; Gobin, Maya; Anderson, Charlotte; Charlett, André; Coole, Louise; Maguire, Helen; Nichols, Tom; Rawlings, Chas; Ramsay, Mary; Oliver, Isabel
2014-08-06
In January-March 2013 in England, confirmed measles cases increased in children aged 10-16 years. In April-September 2013, the National Health System and Public Health England launched a national measles-mumps-rubella (MMR) campaign based on data from Child Health Information Systems (CHIS) estimating that approximately 8% in this age group were unvaccinated. We estimated coverage at baseline, and, of those unvaccinated (target), the proportion vaccinated up to 20/08/2013 (mid-point) to inform further public health action. We selected a sample of 6644 children aged 10-16 years using multistage sampling from those reported unvaccinated in CHIS at baseline and validated their records against GP records. We adjusted the CHIS MMR vaccine coverage estimates correcting by the proportion of vaccinated children obtained through sample validation. We validated 5179/6644 (78%) of the sample records. Coverage at baseline was estimated as 94.7% (95% confidence intervals, CI: 93.5-96.0%), lower in London (86.9%, 95%CI: 83.0-90.9%) than outside (96.1%, 95%CI 95.5-96.8%). The campaign reached 10.8% (95%CI: 7.0-14.6%) of the target population, lower in London (7.1%, 95%CI: 4.9-9.3) than in the rest of England (11.4%, 95%CI: 7.0-15.9%). Coverage increased by 0.5% up to 95.3% (95% CI: 94.1-96.4%) but an estimated 210,000 10-16 year old children remained unvaccinated nationally. Baseline MMR coverage was higher than previously reported and was estimated to have reached the 95% campaign objective at midpoint. Eleven per cent of the target population were vaccinated during the campaign, and may be underestimated, especially in London. No further national campaigns are needed but targeted local vaccination activities should be considered. Copyright © 2014 Elsevier Ltd. All rights reserved.
Integrated multiscale biomaterials experiment and modelling: a perspective
Buehler, Markus J.; Genin, Guy M.
2016-01-01
Advances in multiscale models and computational power have enabled a broad toolset to predict how molecules, cells, tissues and organs behave and develop. A key theme in biological systems is the emergence of macroscale behaviour from collective behaviours across a range of length and timescales, and a key element of these models is therefore hierarchical simulation. However, this predictive capacity has far outstripped our ability to validate predictions experimentally, particularly when multiple hierarchical levels are involved. The state of the art represents careful integration of multiscale experiment and modelling, and yields not only validation, but also insights into deformation and relaxation mechanisms across scales. We present here a sampling of key results that highlight both challenges and opportunities for integrated multiscale experiment and modelling in biological systems. PMID:28981126
Cammilleri, Gaetano; Chetta, Michele; Costa, Antonella; Graci, Stefania; Collura, Rosaria; Buscemi, Maria Drussilla; Cusimano, Maria; Alongi, Angelina; Principato, Deborah; Giangrosso, Giuseppe; Vella, Antonio; Ferrantelli, Vincenzo
2016-03-01
Anisakis and other parasites belonging to the Anisakidae family are organisms of interest for human health, because of their high zoonotic potential. Parasites belonging to this family can cause Anisakiasis, a parasitological disease caused by the ingestion of raw, infested fish products. Furthermore, evidence from the EFSA (European Food Safety Authority; EFSA 2010) has highlighted the allergological potential of nematodes belonging to the Anisakis genre. The detection and identification of Anisakidae larvae in fish products requires an initial visual inspection of the fish sample, as well as other techniques such as candling, UV illumination and artificial digestion. The digestion method consists of the simulation of digestive mechanics, which is made possible by the utilization of HCl and pepsin, according to EC Regulation 2075/2005. In this study, a new Anisakidae larvae detection method using a mechanical digestion system called Trichineasy® was developed. A total of 142 fish samples, belonging to 14 different species, were examined to validate the method. A reaction mixture with 100 g of sample, 10 g of pepsin (1:10000 NF) and 50 ml of 10% HCl at 36 ± 1°C for 20 minutes was evaluated to be the best condition for the digestion of fish samples. These parameters have also allowed the detection of viable larvae after digestion. The results confirm this instrumentation as a valuable and safe tool for the detection of Anisakidae larvae in fishery products.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Ji; Fischer, Debra A.; Xie, Ji-Wei
2014-03-01
The planet occurrence rate for multiple stars is important in two aspects. First, almost half of stellar systems in the solar neighborhood are multiple systems. Second, the comparison of the planet occurrence rate for multiple stars to that for single stars sheds light on the influence of stellar multiplicity on planet formation and evolution. We developed a method of distinguishing planet occurrence rates for single and multiple stars. From a sample of 138 bright (K{sub P} < 13.5) Kepler multi-planet candidate systems, we compared the stellar multiplicity rate of these planet host stars to that of field stars. Using dynamicalmore » stability analyses and archival Doppler measurements, we find that the stellar multiplicity rate of planet host stars is significantly lower than field stars for semimajor axes less than 20 AU, suggesting that planet formation and evolution are suppressed by the presence of a close-in companion star at these separations. The influence of stellar multiplicity at larger separations is uncertain because of search incompleteness due to a limited Doppler observation time baseline and a lack of high-resolution imaging observation. We calculated the planet confidence for the sample of multi-planet candidates and find that the planet confidences for KOI 82.01, KOI 115.01, KOI 282.01, and KOI 1781.02 are higher than 99.7% and thus validate the planetary nature of these four planet candidates. This sample of bright Kepler multi-planet candidates with refined stellar and orbital parameters, planet confidence estimation, and nearby stellar companion identification offers a well-characterized sample for future theoretical and observational study.« less
Exploring geo-tagged photos for land cover validation with deep learning
NASA Astrophysics Data System (ADS)
Xing, Hanfa; Meng, Yuan; Wang, Zixuan; Fan, Kaixuan; Hou, Dongyang
2018-07-01
Land cover validation plays an important role in the process of generating and distributing land cover thematic maps, which is usually implemented by high cost of sample interpretation with remotely sensed images or field survey. With an increasing availability of geo-tagged landscape photos, the automatic photo recognition methodologies, e.g., deep learning, can be effectively utilised for land cover applications. However, they have hardly been utilised in validation processes, as challenges remain in sample selection and classification for highly heterogeneous photos. This study proposed an approach to employ geo-tagged photos for land cover validation by using the deep learning technology. The approach first identified photos automatically based on the VGG-16 network. Then, samples for validation were selected and further classified by considering photos distribution and classification probabilities. The implementations were conducted for the validation of the GlobeLand30 land cover product in a heterogeneous area, western California. Experimental results represented promises in land cover validation, given that GlobeLand30 showed an overall accuracy of 83.80% with classified samples, which was close to the validation result of 80.45% based on visual interpretation. Additionally, the performances of deep learning based on ResNet-50 and AlexNet were also quantified, revealing no substantial differences in final validation results. The proposed approach ensures geo-tagged photo quality, and supports the sample classification strategy by considering photo distribution, with accuracy improvement from 72.07% to 79.33% compared with solely considering the single nearest photo. Consequently, the presented approach proves the feasibility of deep learning technology on land cover information identification of geo-tagged photos, and has a great potential to support and improve the efficiency of land cover validation.
Adjustable Nyquist-rate System for Single-Bit Sigma-Delta ADC with Alternative FIR Architecture
NASA Astrophysics Data System (ADS)
Frick, Vincent; Dadouche, Foudil; Berviller, Hervé
2016-09-01
This paper presents a new smart and compact system dedicated to control the output sampling frequency of an analogue-to-digital converters (ADC) based on single-bit sigma-delta (ΣΔ) modulator. This system dramatically improves the spectral analysis capabilities of power network analysers (power meters) by adjusting the ADC's sampling frequency to the input signal's fundamental frequency with a few parts per million accuracy. The trade-off between straightforwardness and performance that motivated the choice of the ADC's architecture are preliminary discussed. It particularly comes along with design considerations of an ultra-steep direct-form FIR that is optimised in terms of size and operating speed. Thanks to compact standard VHDL language description, the architecture of the proposed system is particularly suitable for application-specific integrated circuit (ASIC) implementation-oriented low-power and low-cost power meter applications. Field programmable gate array (FPGA) prototyping and experimental results validate the adjustable sampling frequency concept. They also show that the system can perform better in terms of implementation and power capabilities compared to dedicated IP resources.
González-Mancebo, E; Alonso Díaz de Durana, M D; García Estringana, Y; Meléndez Baltanás, A; Rodriguez-Alvarez, M; de la Hoz Caballer, B; Del Prado, N; Fernández-Rivas, M
The double-blind, placebo-controlled food challenge (DBPCFC) is considered the definitive diagnostic test for food allergy. Nevertheless, validated recipes for masking the foods are scarce, have not been standardized, and differ between centers. Sensory evaluation techniques such as the triangle test are necessary to validate the recipes used for DBPCFC. We developed 3 recipes for use in DBPCFC with milk, egg white, and hazelnut and used the triangle test to validate them in a 2-phase study in which 197 volunteers participated. In each phase, participants tried 3 samples (2 active-1 placebo or 2 placebo-1 active) and had to identify the odd one. In phase 1, the 3 samples were given simultaneously, whereas in phase 2, the 3 samples of foods that failed validation in phase 1 were given sequentially. A visual analog scale (VAS) ranging from 1 to 10 was used to evaluate how much participants liked the recipes. In phase 1, the egg white recipe was validated (n=89 volunteers, 38.9% found the odd sample, P=.16). Milk and hazelnut recipes were validated in phase 2 (for both foods, n=30 participants, 36.7% found the odd sample, P=.36). Median VAS scores for the 3 recipes ranged from 6.6 to 9.7. We used sensory testing to validate milk, egg white, and hazelnut recipes for use in DBPCFC. The validated recipes are easy to prepare in a clinical setting, provide the equivalent of 1 serving dose, and were liked by most participants.
García-Chao, María; Agruña, María Jesús; Flores Calvete, Gonzalo; Sakkas, Vasilis; Llompart, María; Dagnac, Thierry
2010-07-05
The use of pesticides to protect crops against plagues and insects is one of the most important ways to assure agricultural quality and productivity. However, bad application practices may cause the contamination of different environmental compartments and animal species, as a consequence of migration or accumulation of those compounds. Fipronil, imidacloprid and thiametoxam are systemic or systemic-like insecticides widely used in maize crops. Their heavy action in the nervous system of target insects also means a high toxicity to non-target pollinator insects such as honey bees which can get in touch with them through pollen and nectar during foraging activities. These insecticides have even been suspected to cause a significant decrease of honeybee colonies that has been observed in many countries since the past decade. Since September 1st 2008, the European Commission set new MRLs in food and feed of plant and animal origin. The pesticides included in this study have MRLs in honey and pollen between 10 and 50 ng g(-1). In the present work, an analytical method was developed with the aim of determining residues of fipronil and some of its metabolites (fipronil sulfone, fipronil sulfide, fipronil desulfinyl and fipronil carboxamide), thiamethoxam and imidacloprid in honey and pollen samples. The extraction optimization was performed using a Doehlert experimental design by studying two factors, the mixture and the ratio of solvents used. Prior to the extraction procedure, raw hive samples containing honey, pollen and wax were centrifuged at 4000 rpm. The upper solid material was removed, and 1 g of the lower phase was mixed with 3 mL of the optimized mixture of methanol/water (10/90). The extract was passed through a florisil cartridge and the target compounds were eluted with methanol and analysed by LC-MS/MS in selective reaction monitoring (SRM) mode. The method was validated according to the guidelines included in the SANCO/10684/2009 document and the ISO 11843 standard for the following parameters: decision limit (CCalpha), detection capability (CCbeta), recovery, repeatability and reproducibility at 0.5, 1 and 1.5 folds the MRLs. Ion suppression/enhancement effects into the ion source were also assessed. The CCbeta values were included between 0.83 and 4.83 ng g(-1), well below the current MRLs. The validated method was applied to the determination of the target pesticides in 91 samples collected in colonies from 73 apiaries of NW Spain (two sampling campaigns during 2008). None of the target insecticides were detected among all the collected samples. Copyright 2010 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Lu, Zenghai; Kasaragod, Deepa K.; Matcher, Stephen J.
2011-06-01
A phase fluctuation calibration method is presented for polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) using continuous polarization modulation. The method consists of the generation of a continuous triggered tone-burst waveform rather than an asynchronous waveform by use of a function generator and the removal of the global phases of the measured Jones matrices by use of matrix normalization. This could remove the use of auxiliary optical components for the phase fluctuation compensation in the system, which reduces the system complexity. Phase fluctuation calibration is necessary to obtain the reference Jones matrix by averaging the measured Jones matrices at sample surfaces. Measurements on an equine tendon sample were made by the PS-SS-OCT system to validate the proposed method.
Designing to Sample the Unknown: Lessons from OSIRIS-REx Project Systems Engineering
NASA Technical Reports Server (NTRS)
Everett, David; Mink, Ronald; Linn, Timothy; Wood, Joshua
2017-01-01
On September 8, 2016, the third NASA New Frontiers mission launched on an Atlas V 411. The Origins, Spectral Interpretation, Resource Identification, Security-Regolith Explorer (OSIRIS-REx) will rendezvous with asteroid Bennu in 2018, collect a sample in 2020, and return that sample to Earth in September 2023. The development team has overcome a number of challenges in order to design and build a system that will make contact with an unexplored, airless, low-gravity body. This paper will provide an overview of the mission, then focus in on the system-level challenges and some of the key system-level processes. Some of the lessons here are unique to the type of mission, like discussion of operating at a largely-unknown, low-gravity object. Other lessons, particularly from the build phase, have broad implications. The OSIRIS-REx risk management process was particularly effective in achieving an on-time and under-budget development effort. The systematic requirements management and verification and the system validation also helped identify numerous potential problems. The final assessment of the OSIRIS-REx performance will need to wait until the sample is returned in 2023, but this post-launch assessment will capture some of the key systems-engineering lessons from the development team.
Mayer, B; Muche, R
2013-01-01
Animal studies are highly relevant for basic medical research, although their usage is discussed controversially in public. Thus, an optimal sample size for these projects should be aimed at from a biometrical point of view. Statistical sample size calculation is usually the appropriate methodology in planning medical research projects. However, required information is often not valid or only available during the course of an animal experiment. This article critically discusses the validity of formal sample size calculation for animal studies. Within the discussion, some requirements are formulated to fundamentally regulate the process of sample size determination for animal experiments.
Erdodi, Laszlo A; Sagar, Sanya; Seke, Kristian; Zuccato, Brandon G; Schwartz, Eben S; Roth, Robert M
2018-06-01
This study was designed to develop performance validity indicators embedded within the Delis-Kaplan Executive Function Systems (D-KEFS) version of the Stroop task. Archival data from a mixed clinical sample of 132 patients (50% male; M Age = 43.4; M Education = 14.1) clinically referred for neuropsychological assessment were analyzed. Criterion measures included the Warrington Recognition Memory Test-Words and 2 composites based on several independent validity indicators. An age-corrected scaled score ≤6 on any of the 4 trials reliably differentiated psychometrically defined credible and noncredible response sets with high specificity (.87-.94) and variable sensitivity (.34-.71). An inverted Stroop effect was less sensitive (.14-.29), but comparably specific (.85-90) to invalid performance. Aggregating the newly developed D-KEFS Stroop validity indicators further improved classification accuracy. Failing the validity cutoffs was unrelated to self-reported depression or anxiety. However, it was associated with elevated somatic symptom report. In addition to processing speed and executive function, the D-KEFS version of the Stroop task can function as a measure of performance validity. A multivariate approach to performance validity assessment is generally superior to univariate models. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Evaluation of GasmetTM DX-4015 Series Fourier Transform Infrared Gas Analyzer
2009-06-01
penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number PLEASE DO NOT RETURN YOUR...Series FTIR Gas Analyzer Instrument test conditions simulated current ALS Increment 0 conditions. Briefly, unknown samples are collected in a "hot...a 1M cell. Emission radiation can be collected following a reflection or transmission process. Only one system is being considered and that system
Shewale, Jaiprakash G; Schneida, Elaine; Wilson, Jonathan; Walker, Jerilyn A; Batzer, Mark A; Sinha, Sudhir K
2007-03-01
The human DNA quantification (H-Quant) system, developed for use in human identification, enables quantitation of human genomic DNA in biological samples. The assay is based on real-time amplification of AluYb8 insertions in hominoid primates. The relatively high copy number of subfamily-specific Alu repeats in the human genome enables quantification of very small amounts of human DNA. The oligonucleotide primers present in H-Quant are specific for human DNA and closely related great apes. During the real-time PCR, the SYBR Green I dye binds to the DNA that is synthesized by the human-specific AluYb8 oligonucleotide primers. The fluorescence of the bound SYBR Green I dye is measured at the end of each PCR cycle. The cycle at which the fluorescence crosses the chosen threshold correlates to the quantity of amplifiable DNA in that sample. The minimal sensitivity of the H-Quant system is 7.6 pg/microL of human DNA. The amplicon generated in the H-Quant assay is 216 bp, which is within the same range of the common amplifiable short tandem repeat (STR) amplicons. This size amplicon enables quantitation of amplifiable DNA as opposed to a quantitation of degraded or nonamplifiable DNA of smaller sizes. Development and validation studies were performed on the 7500 real-time PCR system following the Quality Assurance Standards for Forensic DNA Testing Laboratories.
Validating long-term satellite-derived disturbance products: the case of burned areas
NASA Astrophysics Data System (ADS)
Boschetti, L.; Roy, D. P.
2015-12-01
The potential research, policy and management applications of satellite products place a high priority on providing statements about their accuracy. A number of NASA, ESA and EU funded global and continental burned area products have been developed using coarse spatial resolution satellite data, and have the potential to become part of a long-term fire Climate Data Record. These products have usually been validated by comparison with reference burned area maps derived by visual interpretation of Landsat or similar spatial resolution data selected on an ad hoc basis. More optimally, a design-based validation method should be adopted that is characterized by the selection of reference data via a probability sampling that can subsequently be used to compute accuracy metrics, taking into account the sampling probability. Design based techniques have been used for annual land cover and land cover change product validation, but have not been widely used for burned area products, or for the validation of global products that are highly variable in time and space (e.g. snow, floods or other non-permanent phenomena). This has been due to the challenge of designing an appropriate sampling strategy, and to the cost of collecting independent reference data. We propose a tri-dimensional sampling grid that allows for probability sampling of Landsat data in time and in space. To sample the globe in the spatial domain with non-overlapping sampling units, the Thiessen Scene Area (TSA) tessellation of the Landsat WRS path/rows is used. The TSA grid is then combined with the 16-day Landsat acquisition calendar to provide tri-dimensonal elements (voxels). This allows the implementation of a sampling design where not only the location but also the time interval of the reference data is explicitly drawn by probability sampling. The proposed sampling design is a stratified random sampling, with two-level stratification of the voxels based on biomes and fire activity (Figure 1). The novel validation approach, used for the validation of the MODIS and forthcoming VIIRS global burned area products, is a general one, and could be used for the validation of other global products that are highly variable in space and time and is required to assess the accuracy of climate records. The approach is demonstrated using a 1 year dataset of MODIS fire products.
Nieri, Alexandra-Stavroula; Manousaki, Kalliopi; Kalafati, Maria; Padilha, Katia Grilio; Stafseth, Siv K; Katsoulas, Theodoros; Matziou, Vasiliki; Giannakopoulou, Margarita
2018-04-11
To assess the reliability and validity of the Greek version of Nursing Activities Score (NAS), and Therapeutic Intervention Scoring System for Critically Ill Children (TISS-C) in a Greek Paediatric Intensive Care Unit (PICU). A methodological study was performed in one PICU of the largest Paediatric Hospital in Athens-Greece. The culturally adapted and validated Greek NAS version, enriched according to the Norwegian paediatric one (P-NAS), was used. TISS-C and Norwegian paediatric interventions were translated to Greek language and backwards. Therapeutic Intervention Scoring System (TISS-28) was used as a gold standard. Two independent observers simultaneously recorded 30 daily P-NAS and TISS-C records. Totally, 188 daily P-NAS, TISS-C and TISS-28 reports in a sample of 29 patients have been obtained during 5 weeks. Descriptive statistics, reliability and validity measures were applied using SPSS (ver 22.0) (p ≤ 0.05). Kappa was 0.963 for P-NAS and 0.9895 for TISS-C (p < 0.001) and Intraclass Correlation Coefficient for all scale items of TISS-C was 1.00 (p < 0.001). P-NAS, TISS-28 and TISS-C measurements were significantly correlated (0.680 ≤ rho ≤ 0.743, p < 0.001). The mean score(±SD) for TISS-28, P-NAS and TISS-C was 23.05(±5.72), 58.14(±13.98) and 20.21(±9.66) respectively. These results support the validity of P-NAS and TISS-C scales to be used in Greek PICUs. Copyright © 2018 Elsevier Ltd. All rights reserved.
Sommer, D; Enderlein, D; Antakli, A; Schönenbrücher, H; Slaghuis, J; Redmann, T; Lierz, M
2012-01-01
The efficiency of two commercial PCR methods based on real-time technology, the foodproof® Salmonella detection system and the BAX® PCR Assay Salmonella system was compared to standardized culture methods (EN ISO 6579:2002 - Annex D) for the detection of Salmonella spp. in poultry samples. Four sample matrices (feed, dust, boot swabs, feces) obtained directly from poultry flocks, as well as artificially spiked samples of the same matrices, were used. All samples were tested for Salmonella spp. using culture methods first as the gold standard. In addition samples spiked with Salmonella Enteridis were tested to evaluate the sensitivity of both PCR methods. Furthermore all methods were evaluated in an annual ring-trial of the National Salmonella Reference Laboratory of Germany. Salmonella detection in the matrices feed, dust and boot swabs were comparable in both PCR systems whereas the results from feces differed markedly. The quality, especially the freshness, of the fecal samples had an influence on the sensitivity of the real-time PCR and the results of the culture methods. In fresh fecal samples an initial spiking level of 100cfu/25g Salmonella Enteritidis was detected. Two-days-dried fecal samples allowed the detection of 14cfu/25g. Both real- time PCR protocols appear to be suitable for the detection of Salmonella spp. in all four matrices. The foodproof® system detected eight samples more to be positive compared to the BAX® system, but had a potential false positive result in one case. In 7-days-dried samples none of the methods was able to detect Salmonella likely through letal cell damage. In general the advantage of PCR analyses over the culture method is the reduction of working time from 4-5 days to only 2 days. However, especially for the analysis of fecal samples official validation should be conducted according to the requirement of EN ISO6579:2002 - Annex D.
Convergent, discriminant, and criterion validity of DSM-5 traits.
Yalch, Matthew M; Hopwood, Christopher J
2016-10-01
Section III of the Diagnostic and Statistical Manual of Mental Disorders (5th edi.; DSM-5; American Psychiatric Association, 2013) contains a system for diagnosing personality disorder based in part on assessing 25 maladaptive traits. Initial research suggests that this aspect of the system improves the validity and clinical utility of the Section II Model. The Computer Adaptive Test of Personality Disorder (CAT-PD; Simms et al., 2011) contains many similar traits as the DSM-5, as well as several additional traits seemingly not covered in the DSM-5. In this study we evaluate the convergent and discriminant validity between the DSM-5 traits, as assessed by the Personality Inventory for DSM-5 (PID-5; Krueger et al., 2012), and CAT-PD in an undergraduate sample, and test whether traits included in the CAT-PD but not the DSM-5 provide incremental validity in association with clinically relevant criterion variables. Results supported the convergent and discriminant validity of the PID-5 and CAT-PD scales in their assessment of 23 out of 25 DSM-5 traits. DSM-5 traits were consistently associated with 11 criterion variables, despite our having intentionally selected clinically relevant criterion constructs not directly assessed by DSM-5 traits. However, the additional CAT-PD traits provided incremental information above and beyond the DSM-5 traits for all criterion variables examined. These findings support the validity of pathological trait models in general and the DSM-5 and CAT-PD models in particular, while also suggesting that the CAT-PD may include additional traits for consideration in future iterations of the DSM-5 system. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Machado, Roberta Ismael Lacerda; Souto, Lais Medeiros; Freire, Eutilia Andrade Medeiros
2014-01-01
Systemic sclerosis (SSc) is a multisystem disease, autoimmune disorder characterized by a fibroblastic disfunction, with significant impact on quality of life (QoL), measured by instruments or questionnaires that usually were formulated in other languages and in different cultural contexts. Translate into Brazilian Portuguese, cross cultural adaptation and assess the reliability and validity of the Systemic Sclerosis Questionnaire (SySQ). Translation and adaptation: into Portuguese and cross-cultural adaptation was performed in accordance with studies on questionnaire translation methodology into other languages. Reliability: it was analyzed using three interviews with different interviewers, two on the same day (interobserver) and the third within 14 days of the first assessment (intraobserver).Validity was assessed by correlating clinical and quality of life parameters with the domain scores of Sysc. a descriptive analysis of the study sample. Reproducibility was assessed using an intraclass correlation coefficient (ICC). Internal consistency was assessed using Cronbach's alpha coefficient. To assess validity we used Spearman correlation coefficient. Five percent was the level of significance adopted for all statistical tests. In the evaluation of the questionnaires, the results were similar to the original questionnaire, the internal consistency ranging between 0.73 and 0.93 for each item. The interobserver reproducibility was very good for all domains (α = 0.786 to 0.983) and intraobserver agreement was considered very good for general symptoms domain (ICC = 0.916), good for musculoskeletal symptoms domain (ICC = 0.897) and cardiopulmonary domain (ICC = 0.842) and reasonable for gastrointestinal symptoms domain (ICC = 0.686). The Brazilian Portuguese version of SySQ proved to be reproducible and valid for our population, using a recognized methodology for translation and cultural adaptation of questionnaires, as well as to assess the reproducibility and validity.
The prevalence and nature of intellectual disability in Norwegian prisons.
Søndenaa, E; Rasmussen, K; Palmstierna, T; Nøttestad, J
2008-12-01
The objective of the study was to calculate the prevalence of inmates with intellectual disabilities (ID), and identify historical, medical and criminological characteristics of a certain impact. A random sample of 143 inmates from a Norwegian prison cross sectional sample was studied. The Hayes Ability Screening Index (HASI) was validated with the Wechsler Abbreviated Scale of Intelligence (WASI). The prevalence of inmates with ID, IQ < 70, was 10.8%. Some essential characteristics of inmates with ID were more frequent medication for mental disorders, a higher number of imprisonments, less drug abuse and less education than the other inmates. The results indicated that the HASI is a valid tool for screening of ID for the Norwegian inmates. The prevalence of ID in Norwegian inmates is significant, measured by WASI and HASI. Identification, rehabilitation and care, concerning an intellectual handicap, are mostly absent in the Norwegian criminal justice system.
Fujita, Hiroyuki; Honda, Katsuhisa; Hamada, Noriaki; Yasunaga, Genta; Fujise, Yoshihiro
2009-02-01
Validation of a high-throughput measurement system with microwave-assisted extraction (MAE), fully automated sample preparation device (SPD), and gas chromatography-electron capture detector (GC-ECD) for the determination of polychlorinated biphenyls (PCBs) in minke whale blubber was performed. PCB congeners accounting for > 95% of the total PCBs burden in blubber were efficiently extracted with a small volume (20 mL) of n-hexane using MAE due to simultaneous saponification and extraction. Further, the crude extract obtained by MAE was rapidly purified and automatically substituted to a small volume (1 mL) of toluene using SPD without using concentrators. Furthermore, the concentration of PCBs in the purified and concentrated solution was accurately determined by GC-ECD. Moreover, the result of accuracy test using a certified material (SRM 1588b; Cod liver oil) showed good agreement with the NIST certified concentration values. In addition, the method quantification limit of total-PCB in whale blubbers was 41 ng g(-1). This new measurement system for PCBs takes only four hours. Consequently, it indicated this method is the most suitable for the monitoring and screening of PCBs in the conservation of the marine ecosystem and safe distribution of foods.
Measurement of stream channel habitat using sonar
Flug, Marshall; Seitz, Heather; Scott, John
1998-01-01
An efficient and low cost technique using a sonar system was evaluated for describing channel geometry and quantifying inundated area in a large river. The boat-mounted portable sonar equipment was used to record water depths and river width measurements for direct storage on a laptop computer. The field data collected from repeated traverses at a cross-section were evaluated to determine the precision of the system and field technique. Results from validation at two different sites showed average sample standard deviations (S.D.s) of 0.12 m for these complete cross-sections, with coefficient of variations of 10%. Validation using only the mid-channel river cross-section data yields an average sample S.D. of 0.05 m, with a coefficient of variation below 5%, at a stable and gauged river site using only measurements of water depths greater than 0.6 m. Accuracy of the sonar system was evaluated by comparison to traditionally surveyed transect data from a regularly gauged site. We observed an average mean squared deviation of 46.0 cm2, considering only that portion of the cross-section inundated by more than 0.6 m of water. Our procedure proved to be a reliable, accurate, safe, quick, and economic method to record river depths, discharges, bed conditions, and substratum composition necessary for stream habitat studies.
Chandramouli, Balasubramanian; Mancini, Giordano
2016-01-01
Classical Molecular Dynamics (MD) simulations can provide insights at the nanoscopic scale into protein dynamics. Currently, simulations of large proteins and complexes can be routinely carried out in the ns-μs time regime. Clustering of MD trajectories is often performed to identify selective conformations and to compare simulation and experimental data coming from different sources on closely related systems. However, clustering techniques are usually applied without a careful validation of results and benchmark studies involving the application of different algorithms to MD data often deal with relatively small peptides instead of average or large proteins; finally clustering is often applied as a means to analyze refined data and also as a way to simplify further analysis of trajectories. Herein, we propose a strategy to classify MD data while carefully benchmarking the performance of clustering algorithms and internal validation criteria for such methods. We demonstrate the method on two showcase systems with different features, and compare the classification of trajectories in real and PCA space. We posit that the prototype procedure adopted here could be highly fruitful in clustering large trajectories of multiple systems or that resulting especially from enhanced sampling techniques like replica exchange simulations. Copyright: © 2016 by Fabrizio Serra editore, Pisa · Roma.
Structural Validity of CLASS K-3 in Primary Grades: Testing Alternative Models
ERIC Educational Resources Information Center
Sandilos, Lia E.; Shervey, Sarah Wollersheim; DiPerna, James C.; Lei, Puiwa; Cheng, Weiyi
2017-01-01
This study examined the internal structure of the Classroom Assessment Scoring System (CLASS; K-3 version). The original CLASS K-3 model (Pianta, La Paro, & Hamre, 2008) and 5 alternative models were tested using confirmatory factor analysis with a sample of first- and second-grade classrooms (N = 141). Findings indicated that a slightly…
Jiang, Jian; James, Christopher A; Wong, Philip
2016-09-05
A LC-MS/MS method has been developed and validated for the determination of glycine in human cerebrospinal fluid (CSF). The validated method used artificial cerebrospinal fluid as a surrogate matrix for calibration standards. The calibration curve range for the assay was 100-10,000ng/mL and (13)C2, (15)N-glycine was used as an internal standard (IS). Pre-validation experiments were performed to demonstrate parallelism with surrogate matrix and standard addition methods. The mean endogenous glycine concentration in a pooled human CSF determined on three days by using artificial CSF as a surrogate matrix and the method of standard addition was found to be 748±30.6 and 768±18.1ng/mL, respectively. A percentage difference of -2.6% indicated that artificial CSF could be used as a surrogate calibration matrix for the determination of glycine in human CSF. Quality control (QC) samples, except the lower limit of quantitation (LLOQ) QC and low QC samples, were prepared by spiking glycine into aliquots of pooled human CSF sample. The low QC sample was prepared from a separate pooled human CSF sample containing low endogenous glycine concentrations, while the LLOQ QC sample was prepared in artificial CSF. Standard addition was used extensively to evaluate matrix effects during validation. The validated method was used to determine the endogenous glycine concentrations in human CSF samples. Incurred sample reanalysis demonstrated reproducibility of the method. Copyright © 2016 Elsevier B.V. All rights reserved.
Strategic orientations of small multihospital systems.
Luke, R D; Begun, J W
1988-01-01
Strategic behaviors of organizations can be classified along two dimensions--growth orientations, or patterns of evolution over time, and action orientations, or strategic aggressiveness in undertaking a particular growth orientation. We create measures of growth and action orientations for small multihospital systems and test the validity of the growth and action orientation typologies, using data from a sample of small multihospital systems. Growth and action orientations do appear to exist independently of each other, and they are related to the ownership status of the systems. Not-for-profit and church-other systems exhibit similar strategic orientations, unlike those of Catholic and investor-owned systems. PMID:3060448
Peng, Ming; Liu, Jin; Lu, Dan; Yang, Yong-Jian
2012-09-01
Blonanserin is a novel atypical antipsychotic agent for the treatment of schizophrenia. Ethyl alcohol, isopropyl alcohol and toluene are utilized in the synthesis route of this bulk drug. A new validated gas chromatographic (GC) method for the simultaneous determination of residual solvents in blonanserin is described in this paper. Blonanserin was dissolved in N, N-dimethylformamide to make a sample solution that was directly injected into a DB-624 column. A postrun oven temperature at 240°C for approximately 2 h after the analysis cycle was performed to wash out blonanserin residue in the GC column. Quantitation was performed by external standard analyses and the validation was carried out according to International Conference on Harmonization validation guidelines Q2A and Q2B. The method was shown to be specific (no interference in the blank solution), linear (correlation coefficients ≥0.99998, n = 10), accurate (average recoveries between 94.1 and 101.7%), precise (intra-day and inter-day precision ≤2.6%), sensitive (limit of detection ≤0.2 ng, and limit of quantitation ≤0.7 ng), robust (small variations of carrier gas flow, initial oven temperature, temperature ramping rate, injector and detector temperatures did not significantly affect the system suitability test parameters and peak areas) and stable (reference standard and sample solutions were stable over 48 h). This extensively validated method is ready to be used for the quality control of blonanserin.
Carlozzi, Noelle E; Ianni, Phillip A; Tulsky, David S; Brickell, Tracey A; Lange, Rael T; French, Louis M; Cella, David; Kallen, Michael A; Miner, Jennifer A; Kratz, Anna L
2018-06-19
To examine the reliability and validity of Patient Reported Outcomes Measurement Information System (PROMIS) measures of sleep disturbance and fatigue in TBI caregivers and to determine the severity of fatigue and sleep disturbance in these caregivers. Cross-sectional survey data collected through an online data capture platform. Four rehabilitation hospitals and Walter Reed National Military Medical Center. Caregivers (N=560) of civilians (n=344) and service member/veterans (n=216) with TBI. Not Applicable MAIN OUTCOME MEASURES: PROMIS sleep and fatigue measures administered as both computerized adaptive tests (CATs) and 4-item short forms (SFs). For both samples, floor and ceiling effects for the PROMIS measures were low (<11%), internal consistency was very good (all alphas ≥0.80), and test-retest reliability was acceptable (all r≥0.70 except for the fatigue CAT in the service member/veteran sample r=0.63). Convergent validity was supported by moderate correlations between the PROMIS and related measures. Discriminant validity was supported by low correlations between PROMIS measures and measures of dissimilar constructs. PROMIS scores indicated significantly worse sleep and fatigue for those caring for someone with high levels versus low levels of impairment. Findings support the reliability and validity of the PROMIS CAT and SF measures of sleep disturbance and fatigue in caregivers of civilians and service members/veterans with TBI. Copyright © 2018. Published by Elsevier Inc.
Beyond 10 Years of Evolving the IGSN Architecture: What's Next?
NASA Astrophysics Data System (ADS)
Lehnert, K.; Arko, R. A.
2016-12-01
The IGSN was developed as part of a US NSF-funded project, which started in 2004 to establish a registry for sample metadata, the System for Earth Sample Registration (SESAR). The initial version of the system provided a centralized solution for users to submit information about their samples and obtain IGSNs and bar codes. A new distributed architecture for the IGSN was designed at a workshop in 2011 that aimed to advance the global implementation of the IGSN. The workshop led to the founding of an international non-profit organization, the IGSN e.V., that adopted the governance model of the DataCite consortium as a non-profit membership organization and its architecture with a central registry and a network of distributed Allocating Agents that provide registration services to the users. Recent progress came at a workshop in 2015, where stakeholders from both geoscience and life science disciplines drafted a standard IGSN metadata schema for describing samples with an essential set of properties about the sample's origin and classification, creating a "birth certificate" for the sample. Consensus was reached that the IGSN should also be used to identify sampling features and collection of samples. The IGSN e.V. global network has steadily grown, with now members in 4 continents and 5 Allocating Agents operational in the US, Australia, and Europe. A Central Catalog has been established at the IGSN Management Office that harvests "birth certificate" metadata records from Allocating Agents via the Open Archives Initiative Protocol for Metadata Harvest (OAI-PMH), and publishes them as a Linked Open Data graph using the Resource Description Framework (RDF) and RDF Query Language (SPARQL) for reuse by Semantic Web clients. Next developments will include a web-based validation service that allows journal editors to check the validity of IGSNs and compliance with metadata requirements, and use of community-recommended vocabularies for specific disciplines.
A Simple Method to Quantitate IP-10 in Dried Blood and Plasma Spots
Aabye, Martine G.; Eugen-Olsen, Jesper; Werlinrud, Anne Marie; Holm, Line Lindebo; Tuuminen, Tamara; Ravn, Pernille; Ruhwald, Morten
2012-01-01
Background Antigen specific release of IP-10 is an established marker for infection with M.tuberculosis. Compared to IFN-γ, IP-10 is released in 100-fold higher concentrations enabling the development of novel assays for detection. Dried blood spots are a convenient sample for high throughput newborn screening. Aim To develop a robust and sensitive ELISA-based assay for IP-10 detection in plasma, dried blood spots (DBS) and dried plasma spots (DPS); to validate the ELISA in clinically relevant samples; and to assess the performance of the assay for detection of Cytomegalovirus (CMV) and M.tuberculosis specific immune responses. Method We raised mice and rat monoclonal antibodies against human IP-10 and developed an ELISA. The assay was validated and applied to the detection of CMV and M.tuberculosis specific responses in 18 patients with immune reactivity towards M.tuberculosis and 32 healthy controls of which 22 had immune reactivity towards CMV and none towards M.tuberculosis. We compared the performance of this new assay to IFN-γ. Results The ELISA was reliable for IP-10 detection in both plasma and filter paper samples. The linear range of the ELISA was 2.5–600 pg/ml. IFN-γ was not readily detectable in DPS samples. IP-10 was stabile in filter paper samples for at least 4 weeks at 37°C. The correlation between IP-10 detected in plasma, DPS and DBS samples was excellent (r2>0.97). Conclusions This newly developed assay is reliable for IP-10 quantification in plasma, DBS and DPS samples from antigen stimulated and non-stimulated whole blood. The filter paper assays enable easy sample acquisition and transport at ambient temperature e.g. via the postal system. The system can potentially simplify diagnostic assays for M.tuberculosis and CMV infection. PMID:22761744
External validation of a Cox prognostic model: principles and methods
2013-01-01
Background A prognostic model should not enter clinical practice unless it has been demonstrated that it performs a useful role. External validation denotes evaluation of model performance in a sample independent of that used to develop the model. Unlike for logistic regression models, external validation of Cox models is sparsely treated in the literature. Successful validation of a model means achieving satisfactory discrimination and calibration (prediction accuracy) in the validation sample. Validating Cox models is not straightforward because event probabilities are estimated relative to an unspecified baseline function. Methods We describe statistical approaches to external validation of a published Cox model according to the level of published information, specifically (1) the prognostic index only, (2) the prognostic index together with Kaplan-Meier curves for risk groups, and (3) the first two plus the baseline survival curve (the estimated survival function at the mean prognostic index across the sample). The most challenging task, requiring level 3 information, is assessing calibration, for which we suggest a method of approximating the baseline survival function. Results We apply the methods to two comparable datasets in primary breast cancer, treating one as derivation and the other as validation sample. Results are presented for discrimination and calibration. We demonstrate plots of survival probabilities that can assist model evaluation. Conclusions Our validation methods are applicable to a wide range of prognostic studies and provide researchers with a toolkit for external validation of a published Cox model. PMID:23496923
Peck, Michelle A; Sturk-Andreaggi, Kimberly; Thomas, Jacqueline T; Oliver, Robert S; Barritt-Ross, Suzanne; Marshall, Charla
2018-05-01
Generating mitochondrial genome (mitogenome) data from reference samples in a rapid and efficient manner is critical to harnessing the greater power of discrimination of the entire mitochondrial DNA (mtDNA) marker. The method of long-range target enrichment, Nextera XT library preparation, and Illumina sequencing on the MiSeq is a well-established technique for generating mitogenome data from high-quality samples. To this end, a validation was conducted for this mitogenome method processing up to 24 samples simultaneously along with analysis in the CLC Genomics Workbench and utilizing the AQME (AFDIL-QIAGEN mtDNA Expert) tool to generate forensic profiles. This validation followed the Federal Bureau of Investigation's Quality Assurance Standards (QAS) for forensic DNA testing laboratories and the Scientific Working Group on DNA Analysis Methods (SWGDAM) validation guidelines. The evaluation of control DNA, non-probative samples, blank controls, mixtures, and nonhuman samples demonstrated the validity of this method. Specifically, the sensitivity was established at ≥25 pg of nuclear DNA input for accurate mitogenome profile generation. Unreproducible low-level variants were observed in samples with low amplicon yields. Further, variant quality was shown to be a useful metric for identifying sequencing error and crosstalk. Success of this method was demonstrated with a variety of reference sample substrates and extract types. These studies further demonstrate the advantages of using NGS techniques by highlighting the quantitative nature of heteroplasmy detection. The results presented herein from more than 175 samples processed in ten sequencing runs, show this mitogenome sequencing method and analysis strategy to be valid for the generation of reference data. Copyright © 2018 Elsevier B.V. All rights reserved.
Overview of the Spinal Cord Injury--Quality of Life (SCI-QOL) measurement system.
Tulsky, David S; Kisala, Pamela A; Victorson, David; Tate, Denise G; Heinemann, Allen W; Charlifue, Susan; Kirshblum, Steve C; Fyffe, Denise; Gershon, Richard; Spungen, Ann M; Bombardier, Charles H; Dyson-Hudson, Trevor A; Amtmann, Dagmar; Kalpakjian, Claire Z; Choi, Seung W; Jette, Alan M; Forchheimer, Martin; Cella, David
2015-05-01
The Spinal Cord Injury--Quality of Life (SCI-QOL) measurement system was developed to address the shortage of relevant and psychometrically sound patient reported outcome (PRO) measures available for clinical care and research in spinal cord injury (SCI) rehabilitation. Using a computer adaptive testing (CAT) approach, the SCI-QOL builds on the Patient Reported Outcomes Measurement Information System (PROMIS) and the Quality of Life in Neurological Disorders (Neuro-QOL) initiative. This initial manuscript introduces the background and development of the SCI-QOL measurement system. Greater detail is presented in the additional manuscripts of this special issue. Classical and contemporary test development methodologies were employed. Qualitative input was obtained from individuals with SCI and clinicians through interviews, focus groups, and cognitive debriefing. Item pools were field tested in a multi-site sample (n=877) and calibrated using item response theory methods. Initial reliability and validity testing was performed in a new sample of individuals with traumatic SCI (n=245). Five Model SCI System centers and one Department of Veterans Affairs Medical Center across the United States. Adults with traumatic SCI. n/a n/a The SCI-QOL consists of 19 item banks, including the SCI-Functional Index banks, and 3 fixed-length scales measuring physical, emotional, and social aspects of health-related QOL (HRQOL). The SCI-QOL measurement system consists of psychometrically sound measures for individuals with SCI. The manuscripts in this special issue provide evidence of the reliability and initial validity of this measurement system. The SCI-QOL also links to other measures designed for a general medical population.
Label-free hyperspectral dark-field microscopy for quantitative scatter imaging
NASA Astrophysics Data System (ADS)
Cheney, Philip; McClatchy, David; Kanick, Stephen; Lemaillet, Paul; Allen, David; Samarov, Daniel; Pogue, Brian; Hwang, Jeeseong
2017-03-01
A hyperspectral dark-field microscope has been developed for imaging spatially distributed diffuse reflectance spectra from light-scattering samples. In this report, quantitative scatter spectroscopy is demonstrated with a uniform scattering phantom, namely a solution of polystyrene microspheres. A Monte Carlo-based inverse model was used to calculate the reduced scattering coefficients of samples of different microsphere concentrations from wavelength-dependent backscattered signal measured by the dark-field microscope. The results are compared to the measurement results from a NIST double-integrating sphere system for validation. Ongoing efforts involve quantitative mapping of scattering and absorption coefficients in samples with spatially heterogeneous optical properties.
Blatchley, E R; Shen, C; Scheible, O K; Robinson, J P; Ragheb, K; Bergstrom, D E; Rokjer, D
2008-02-01
Dyed microspheres have been developed as a new method for validation of ultraviolet (UV) reactor systems. When properly applied, dyed microspheres allow measurement of the UV dose distribution delivered by a photochemical reactor for a given operating condition. Prior to this research, dyed microspheres had only been applied to a bench-scale UV reactor. The goal of this research was to extend the application of dyed microspheres to large-scale reactors. Dyed microsphere tests were conducted on two prototype large-scale UV reactors at the UV Validation and Research Center of New York (UV Center) in Johnstown, NY. All microsphere tests were conducted under conditions that had been used previously in biodosimetry experiments involving two challenge bacteriophage: MS2 and Qbeta. Numerical simulations based on computational fluid dynamics and irradiance field modeling were also performed for the same set of operating conditions used in the microspheres assays. Microsphere tests on the first reactor illustrated difficulties in sample collection and discrimination of microspheres against ambient particles. Changes in sample collection and work-up were implemented in tests conducted on the second reactor that allowed for improvements in microsphere capture and discrimination against the background. Under these conditions, estimates of the UV dose distribution from the microspheres assay were consistent with numerical simulations and the results of biodosimetry, using both challenge organisms. The combined application of dyed microspheres, biodosimetry, and numerical simulation offers the potential to provide a more in-depth description of reactor performance than any of these methods individually, or in combination. This approach also has the potential to substantially reduce uncertainties in reactor validation, thereby leading to better understanding of reactor performance, improvements in reactor design, and decreases in reactor capital and operating costs.
FaSTR DNA: a new expert system for forensic DNA analysis.
Power, Timothy; McCabe, Brendan; Harbison, Sally Ann
2008-06-01
The automation of DNA profile analysis of reference and crime samples continues to gain pace driven in part by a realisation by the criminal justice system of the positive impact DNA technology can have in aiding in the solution of crime and the apprehension of suspects. Expert systems to automate the profile analysis component of the process are beginning to be developed. In this paper, we report the validation of a new expert system FaSTR DNA, an expert system suitable for the analysis of DNA profiles from single source reference samples and from crime samples. We compare the performance of FaSTR DNA with that of other equivalent systems, GeneMapper ID v3.2 (Applied Biosystems, Foster City, CA) and FSS-i(3) v4 (The Forensic Science Service((R)) DNA expert System Suite FSS-i(3), Forensic Science Service, Birmingham, UK) with GeneScan Analysis v3.7/Genotyper v3.7 software (Applied Biosystems, Foster City, CA, USA) with manual review. We have shown that FaSTR DNA provides an alternative solution to automating DNA profile analysis and is appropriate for implementation into forensic laboratories. The FaSTR DNA system was demonstrated to be comparable in performance to that of GeneMapper ID v3.2 and superior to that of FSS-i(3) v4 for the analysis of DNA profiles from crime samples.
Roberts, Michael S; Turner, David C; Owens, Thandranese S; Ramachandran, Abhijit; Wetmore, Cynthia; Throm, Stacy L; Stewart, Clinton F
2013-06-15
A LC-ESI-MS/MS method for the determination of crenolanib (CP-868,596) in human serum was developed and validated employing d4-CP-868,596 as an internal standard (ISTD). In addition to human serum, the method was also partially validated for crenolanib determination in human cerebrospinal fluid (CSF) samples. Sample aliquots (50μl of serum or CSF) were prepared for analysis using liquid-liquid extraction (LLE) with tert-butyl methyl ether. Chromatography was performed using a phenomenex Gemini C18 column (3μm, 100mm×4.6mm I.D.) in a column heater set at 50°C and an isocratic mobile phase (methanol/water/formic acid at a volume ratio of 25/25/0.15, v/v/v). The flow rate was 0.45mL/min, and the retention time for both analyte and ISTD was less than 3.5min. Samples were analyzed with an API-5500 LC-MS/MS system (ESI) in positive ionization mode coupled to a Shimadzu HPLC system. The ion transitions monitored were m/z 444.4→373.1 and m/z 448.2→374.2 for crenolanib and ISTD, respectively. The method was linear over the range of 5-1000ng/mL for serum and 0.5-1000ng/mL for CSF. For human serum, both intra-day and inter-day precision were <4%, while intra-day and inter-day accuracy were within 8% of nominal values. Recovery was greater than 50% for both the analyte and ISTD. For CSF samples, both intra-day and inter-day precision were <9% except at the lower limit of quantification (LLOQ) which was <17%. The intra-day and inter-day accuracy were within 11% of the nominal CSF concentrations. After validation, this method was successfully applied to the analysis of serial pharmacokinetic samples obtained from a child treated with oral crenolanib. Copyright © 2013 Elsevier B.V. All rights reserved.
Symptom-based categorization of in-flight passenger medical incidents.
Mahony, Paul H; Myers, Julia A; Larsen, Peter D; Powell, David M C; Griffiths, Robin F
2011-12-01
The majority of in-flight passenger medical events are managed by cabin crew. Our study aimed to evaluate the reliability of cabin crew reports of in-flight medical events and to develop a symptom-based categorization system. All cabin crew in-flight passenger medical incident reports for an airline over a 9-yr period were examined retrospectively. Validation of incident descriptions were undertaken on a sample of 162 cabin crew reports where medically trained persons' reports were available for comparison using a three Round Delphi technique and testing concordance using Cohen's Kappa. A hierarchical symptom-based categorization system was designed and validated. The rate was 159 incidents per 106 passengers carried, or 70.4/113.3 incidents per 106 revenue passenger kilometres/miles, respectively. Concordance between cabin crew and medical reports was 96%, with a high validity rating (mean 4.6 on a 1-5 scale) and high Cohen's Kappa (0.94). The most common in-flight medical events were transient loss of consciousness (41%), nausea/vomiting/diarrhea (19.5%), and breathing difficulty (16%). Cabin crew records provide reliable data regarding in-flight passenger medical incidents, complementary to diagnosis-based systems, and allow the use of currently underutilized data. The categorization system provides a means for tracking passenger medical incidents internationally and an evidence base for cabin crew first aid training.
Technical note: developmental validation of a novel 6-dye typing system with 36 Y-STR loci.
Du, Weian; Feng, Peipei; Huang, Hongyan; Wu, Weibin; Zhang, Lei; Guo, Yulin; Liu, Changhui; Liu, Hong; Liu, Chao; Chen, Ling
2018-05-30
Y-chromosomal short tandem repeats (Y-STRs) have proven to be very useful in investigating sexual assault cases and in paternity lineage differentiation. However, currently available commercial Y-STR multiplex amplification systems bear the limitations in the identification of related males from the same paternal lineage due to there being an insufficient number of loci in any single amplification kit. The aim of this study was to establish and validate a novel 6-dye, 36-plex Y-STR multiplex amplification system that incorporated all of the loci present in the Yfiler™ Plus kit (DYS19, DYS385a/b, DYF387S1, DYS389I/II, DYS390, DYS391, DYS392, DYS393, DYS437, DYS438, DYS439, DYS448, DYS449, DYS456, DYS458, DYS460, DYS481, DYS518, DYS533, DYS570, DYS576, DYS627, DYS635, Y_GATA_H4) as well as a further nine highly polymorphic Y-STR loci (DYS388, DYS444, DYS447, DYS522, DYS527a/b, DYS549, DYS596, DYS643). The novel system was optimized and validated by a series of studies that tested the effect of different PCR-based conditions as well as the species specificity, sensitivity, stability, stutter precision, suitability for use on DNA mixtures, reproducibility, and parallel testing of the system, as well as its performance on casework samples and population analysis, according to the SWGDAM developmental validation guidelines. A total of 246 haplotypes were found for the 36 Y-STRs among 247 Guangdong Han unrelated males. Collectively, the results demonstrate that the developed 36-plex Y-STR system is sensitive, robust, reliable, and highly informative for use in forensic genetics.
NASA Astrophysics Data System (ADS)
Schaumann, Ina; Malzer, Wolfgang; Mantouvalou, Ioanna; Lühl, Lars; Kanngießer, Birgit; Dargel, Rainer; Giese, Ulrich; Vogt, Carla
2009-04-01
For the validation of the quantification of the newly-developed method of 3D Micro X-ray fluorescence spectroscopy (3D Micro-XRF) samples with a low average Z matrix and minor high Z elements are best suited. In a light matrix the interferences by matrix effects are minimized so that organic polymers are appropriate as basis for analytes which are more easily detected by X-ray fluorescence spectroscopy. Polymer layer systems were assembled from single layers of ethylene-propylene-diene rubber (EPDM) filled with changing concentrations of silica and zinc oxide as inorganic additives. Layer thicknesses were in the range of 30-150 μm. Before the analysis with 3D Micro-XRF all layers have been characterized by scanning micro-XRF with regard to filler dispersion, by infrared microscopy and light microscopy in order to determine the layer thicknesses and by ICP-OES to verify the concentration of the X-ray sensitive elements in the layers. With the results obtained for stacked polymer systems the validity of the analytical quantification model for the determination of stratified materials by 3D Micro-XRF could be demonstrated.
Operational Processing of Ground Validation Data for the Tropical Rainfall Measuring Mission
NASA Technical Reports Server (NTRS)
Kulie, Mark S.; Robinson, Mike; Marks, David A.; Ferrier, Brad S.; Rosenfeld, Danny; Wolff, David B.
1999-01-01
The Tropical Rainfall Measuring Mission (TRMM) satellite was successfully launched in November 1997. A primary goal of TRMM is to sample tropical rainfall using the first active spaceborne precipitation radar. To validate TRMM satellite observations, a comprehensive Ground Validation (GV) Program has been implemented for this mission. A key component of GV is the analysis and quality control of meteorological ground-based radar data from four primary sites: Melbourne, FL; Houston, TX; Darwin, Australia; and Kwajalein Atoll, RMI. As part of the TRMM GV effort, the Joint Center for Earth Systems Technology (JCET) at the University of Maryland, Baltimore County, has been tasked with developing and implementing an operational system to quality control (QC), archive, and provide data for subsequent rainfall product generation from the four primary GV sites. This paper provides an overview of the JCET operational environment. A description of the QC algorithm and performance, in addition to the data flow procedure between JCET and the TRNM science and Data Information System (TSDIS), are presented. The impact of quality-controlled data on higher level rainfall and reflectivity products will also be addressed, Finally, a brief description of JCET's expanded role into producing reference rainfall products will be discussed.
Topaz, Maxim; Lai, Kenneth; Dowding, Dawn; Lei, Victor J; Zisberg, Anna; Bowles, Kathryn H; Zhou, Li
2016-12-01
Electronic health records are being increasingly used by nurses with up to 80% of the health data recorded as free text. However, only a few studies have developed nursing-relevant tools that help busy clinicians to identify information they need at the point of care. This study developed and validated one of the first automated natural language processing applications to extract wound information (wound type, pressure ulcer stage, wound size, anatomic location, and wound treatment) from free text clinical notes. First, two human annotators manually reviewed a purposeful training sample (n=360) and random test sample (n=1100) of clinical notes (including 50% discharge summaries and 50% outpatient notes), identified wound cases, and created a gold standard dataset. We then trained and tested our natural language processing system (known as MTERMS) to process the wound information. Finally, we assessed our automated approach by comparing system-generated findings against the gold standard. We also compared the prevalence of wound cases identified from free-text data with coded diagnoses in the structured data. The testing dataset included 101 notes (9.2%) with wound information. The overall system performance was good (F-measure is a compiled measure of system's accuracy=92.7%), with best results for wound treatment (F-measure=95.7%) and poorest results for wound size (F-measure=81.9%). Only 46.5% of wound notes had a structured code for a wound diagnosis. The natural language processing system achieved good performance on a subset of randomly selected discharge summaries and outpatient notes. In more than half of the wound notes, there were no coded wound diagnoses, which highlight the significance of using natural language processing to enrich clinical decision making. Our future steps will include expansion of the application's information coverage to other relevant wound factors and validation of the model with external data. Copyright © 2016 Elsevier Ltd. All rights reserved.
The Dula Dangerous Driving Index: An Investigation of Reliability and Validity across Cultures
Willemsen, Jochem; Dula, Chris S.; Declercq, Frédéric; Verhaeghe, Paul
2008-01-01
The aim of this study is to further establish the validity and reliability of the Dula Dangerous Driving Index (DDDI). The reliability and validity of the instrument was investigated by comparing data from a US university sample, a US community sample, and a sample of Belgian traffic offenders. Exploratory and confirmatory factor analysis supported the presence of a four-factor structure with items for Drunk Driving forming a separate scale apart from items for Risky Driving, Negative Cognitive/Emotional Driving and Aggressive Driving. A multi-group confirmatory factor analysis with model constraints supported the validity of the DDDI. Inter-correlations revealed that the DDDI subscales are closely interrelated and uni-dimensionality of the measure was found in all three samples. This suggests the DDDI Total score can be used as a composite measure for dangerous driving. However, the validity of the subscales was demonstrated in the Belgian sample, as specific traffic offender groups (convicted for drunk driving, aggressive driving, speeding) scored higher on corresponding scales (Drunk Driving, Aggressive Driving, and Risky Driving, respectively), indicating that it is clinically meaningful to differentiate the subscales. PMID:18329435
Factorial validity of the Job Expectations Questionnaire in a sample of Mexican workers.
Villa-George, Fabiola Itzel; Moreno-Jiménez, Bernardo; Rodríguez-Muñoz, Alfredo; Villalpando Uribe, Jessica
2011-11-01
The aim of this study was to examine the factorial validity of the Job Expectations Questionnaire (Cuestionario de Expectativas Laborales CEL) in a sample of Mexican workers. Following a cross validation approach, two samples were used in the study. The first sample consisted of 380 professionals who mainly performed administrative work in the Health Services in Puebla-Mexico. The second sample comprised 400 health professionals from the Hospital de la Mujer in Puebla-Mexico. Exploratory factor analysis yielded a three-factor solution, accounting for 51.8% of the variance. The results of confirmatory factorial analysis indicate that the three-factor model provided the best fit with the data (CFI = .96, GFI = .95, NNFI = .95, RMSEA = .04), maintaining the structure with 12 items. The reliability of the questionnaire and the diverse subscales showed high internal consistency. Significant correlations were found between job expectations and autonomy, vigor, dedication, and absorption, providing evidence of its construct validity. The evaluation of the psychometric qualities confirms this questionnaire as a valid and specific instrument to measure job expectations.
Olives, Casey; Pagano, Marcello; Deitchler, Megan; Hedt, Bethany L; Egge, Kari; Valadez, Joseph J
2009-04-01
Traditional lot quality assurance sampling (LQAS) methods require simple random sampling to guarantee valid results. However, cluster sampling has been proposed to reduce the number of random starting points. This study uses simulations to examine the classification error of two such designs, a 67x3 (67 clusters of three observations) and a 33x6 (33 clusters of six observations) sampling scheme to assess the prevalence of global acute malnutrition (GAM). Further, we explore the use of a 67x3 sequential sampling scheme for LQAS classification of GAM prevalence. Results indicate that, for independent clusters with moderate intracluster correlation for the GAM outcome, the three sampling designs maintain approximate validity for LQAS analysis. Sequential sampling can substantially reduce the average sample size that is required for data collection. The presence of intercluster correlation can impact dramatically the classification error that is associated with LQAS analysis.
Validity and Reliability of Psychosocial Factors Related to Breast Cancer Screening.
ERIC Educational Resources Information Center
Zapka, Jane G.; And Others
1991-01-01
The construct validity of hypothesized survey items and data reduction procedures for selected psychosocial constructs frequently used in breast cancer screening research were investigated in telephone interviews with randomly selected samples of 1,184 and 903 women and a sample of 169 Hispanic clinic clients. Validity of the constructs is…
NASA Astrophysics Data System (ADS)
Allen, G.; Shah, A.; Williams, P. I.; Ricketts, H.; Hollingsworth, P.; Kabbabe, K.; Bourn, M.; Pitt, J. R.; Helmore, J.; Lowry, D.; Robinson, R. A.; Finlayson, A.
2017-12-01
Emission controls for CH4are a part of the Paris Agreement and other national emissions strategies. This work represents a new method for precise quantification of point-source and facility-level methane emissions flux rates to inform both the climate science community and policymakers. In this paper, we describe the development of an integrated Unmanned Aerial System (UAS) for the measurement of high-precision in-situ CH4 concentrations. We also describe the development of a mass balance flux calculation model tailored to UAS plume sampling downwind; and the validation of this method using a known emission flux from a controlled release facility. A validation field trial was conducted at the UK Met Office site in Cardington, UK, between 31 Oct and 4 Nov 2016 using the UK National Physical Laboratory's Controlled Release Facility (CRF). A modified DJI-S900 hexrotor UAS was tethered via an inlet to a ground-based Los Gatos Ultraportable Greenhouse Gas Analyser to record geospatially-referenced methane (and carbon dioxide) concentrations. Methane fluxes from the CRF were emitted at 5 kg/hr and 10 kg/hr in a series of blind trials (fluxes were not reported to the team prior to the calculation of UAS-derived flux) for a total of 7 UAS flights, which sampled 200 m downwind of source(s), each lasting around 20 minutes. The flux calculation method was adapted for sampling considerations downwind of an emission source that has not had sufficient time to develop a Gaussian morphology. The UAS-measured methane fluxes, and representative flux uncertainty (derived from an error propagation model), were found to compare well with the controlled CH4 emission rate. For the 7 experiments, the standard error between the measured and emitted CH4 flux was found to be +/-6% with a mean bias of +0.4 kg/hr. Limits of flux sensitivity (to within 25% uncertainty) were found to extend to as little as 0.12 kg/h. Further improvements to the accuracy of flux calculation could be made by appropriate onboard measurement of wind speed and direction. This system would yield highly precise flux snapshots (case studies) of methane sources of interest such as oil and gas infrastructure, landfill, and urban environments, to help in the validation of bottom-up emission inventories and in identifying and mitigating so-called super-emitter facilities.
Designing Iranian Model to Assess the Level of Health System Responsiveness.
Askari, Roohollah; Arab, Mohammad; Rashidian, Arash; Akbari-Sari, Ali; Hosseini, Seyed Mostafa; Gharaee, Hojat
2016-03-01
Given the rapid pace of changes in community health needs and the mission of healthcare organizations to provide and promote the community's health, the growing need to increase health system responsiveness to people as a key element of observance and fulfillment of justice is felt more than ever. This study was aimed at designing the native model of responsiveness for Iran and to validate the aspects of the proposed model. Our study had a cross-sectional design and was a validation study performed in 2014. In order to define and identify responsiveness model aspects, the first phase recorded the views of 200 key informants from 19 provinces of Iran. Snowball sampling was used to select experts (based on WHO guideline). Then, the opinions of 18 comments were received from service recipients in the form of three focus group discussions and were analyzed by the frame framework analysis (interviewed recipients were selected using the purposive sampling method). Finally, in order to confirm the model's efficacy, a responsiveness questionnaire with 7 aspects (domains) and 52 indicators (items) obtained from the initial proposed model was answered by 600 members of the selected families in the two provinces of Fars and Yazd. A multi-stage cluster sampling approach was used for the household survey. The results were analyzed by the Confirmatory Factor Analysis (CFA) test and through the use of Lisrel software. Confirmatory Factor Analysis, based on the results of the key informant survey and group discussions, showed that according to quantities of GFI = 0.91, CFI = 0.93, NFI = 0.91, RMSEA = 0.074, SRMR = 0.061 and Hoelter (CN) = 178.54 in outpatient services and where GFI = 0.89, CFI = 0.91, NFI = 0.86, RMSEA = 0.064, SRMR = 0.053 and Hoelter (CN) = 158.93 for inpatient services, seven factors (F) (dignity, informed choice, confidentiality, patient training and informing, access to services, quality of basic amenities, and access to social support) are the main determinants of the responsiveness model and proposed model validity. Given the comprehensiveness of presented aspects and indicators in this proposed model and its validity test, the aforementioned responsiveness model can be considered a suitable model to use when assessing the levels of health system responsiveness in Iran.
Wongpakaran, Tinakon; Wongpakaran, Nahathai
2012-01-01
This study seeks to investigate the psychometric properties of the short version of the revised 'Experience of Close Relationships' questionnaire, comparing non-clinical and clinical samples. In total 702 subjects participated in this study, of whom 531 were non-clinical participants and 171 were psychiatric patients. They completed the short version of the revised 'Experience of Close Relationships' questionnaire (ECR-R-18), the Perceived Stress Scale-10(PSS-10), the Rosenberg Self-Esteem Scale (RSES) and the UCLA Loneliness scale. A retest of the ECR-R-18 was then performed at four-week intervals. Then, confirmatory factor analyses were performed to test the validity of the new scale. The ECR-R-18 showed a fair to good internal consistency (α 0.77 to 0.87) for both samples, and the test-retest reliability was found to be satisfactory (ICC = 0.75). The anxiety sub-scale demonstrated concurrent validity with PSS-10 and RSES, while the avoidance sub-scale showed concurrent validity with the UCLA Loneliness Scale. Confirmatory factor analysis using method factors yielded two factors with an acceptable model fit for both groups. An invariance test revealed that the ECR-R-18 when used on the clinical group differed from when used with the non-clinical group. The ECR-R-18 questionnaire revealed an overall better level of fit than the original 36 item questionnaire, indicating its suitability for use with a broader group of samples, including clinical samples. The reliability of the ECR-R- 18 might be increased if a modified scoring system is used and if our suggestions with regard to future studies are followed up.
The ALICE Software Release Validation cluster
NASA Astrophysics Data System (ADS)
Berzano, D.; Krzewicki, M.
2015-12-01
One of the most important steps of software lifecycle is Quality Assurance: this process comprehends both automatic tests and manual reviews, and all of them must pass successfully before the software is approved for production. Some tests, such as source code static analysis, are executed on a single dedicated service: in High Energy Physics, a full simulation and reconstruction chain on a distributed computing environment, backed with a sample “golden” dataset, is also necessary for the quality sign off. The ALICE experiment uses dedicated and virtualized computing infrastructures for the Release Validation in order not to taint the production environment (i.e. CVMFS and the Grid) with non-validated software and validation jobs: the ALICE Release Validation cluster is a disposable virtual cluster appliance based on CernVM and the Virtual Analysis Facility, capable of deploying on demand, and with a single command, a dedicated virtual HTCondor cluster with an automatically scalable number of virtual workers on any cloud supporting the standard EC2 interface. Input and output data are externally stored on EOS, and a dedicated CVMFS service is used to provide the software to be validated. We will show how the Release Validation Cluster deployment and disposal are completely transparent for the Release Manager, who simply triggers the validation from the ALICE build system's web interface. CernVM 3, based entirely on CVMFS, permits to boot any snapshot of the operating system in time: we will show how this allows us to certify each ALICE software release for an exact CernVM snapshot, addressing the problem of Long Term Data Preservation by ensuring a consistent environment for software execution and data reprocessing in the future.
Mills, Sarah D; Kwakkenbos, Linda; Carrier, Marie-Eve; Gholizadeh, Shadi; Fox, Rina S; Jewett, Lisa R; Gottesman, Karen; Roesch, Scott C; Thombs, Brett D; Malcarne, Vanessa L
2018-01-17
Systemic sclerosis (SSc) is an autoimmune disease that can cause disfiguring changes in appearance. This study examined the structural validity, internal consistency reliability, convergent validity, and measurement equivalence of the Social Appearance Anxiety Scale (SAAS) across SSc disease subtypes. Patients enrolled in the Scleroderma Patient-centered Intervention Network Cohort completed the SAAS and measures of appearance-related concerns and psychological distress. Confirmatory factor analysis (CFA) was used to examine the structural validity of the SAAS. Multiple-group CFA was used to determine if SAAS scores can be compared across patients with limited and diffuse disease subtypes. Cronbach's alpha was used to examine internal consistency reliability. Correlations of SAAS scores with measures of body image dissatisfaction, fear of negative evaluation, social anxiety, and depression were used to examine convergent validity. SAAS scores were hypothesized to be positively associated with all convergent validity measures, with correlations significant and moderate to large in size. A total of 938 patients with SSc were included. CFA supported a one-factor structure (CFI: .92; SRMR: .04; RMSEA: .08), and multiple-group CFA indicated that the scalar invariance model best fit the data. Internal consistency reliability was good in the total sample (α = .96) and in disease subgroups. Overall, evidence of convergent validity was found with measures of body image dissatisfaction, fear of negative evaluation, social anxiety, and depression. The SAAS can be reliably and validly used to assess fear of appearance evaluation in patients with SSc, and SAAS scores can be meaningfully compared across disease subtypes. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Toxoplasma gondii Antibodies in Bulk Tank Milk Samples of Caprine Dairy Herds.
Gazzonis, Alessia Libera; Zanzani, Sergio Aurelio; Stradiotto, Katia; Olivieri, Emanuela; Villa, Luca; Manfredi, Maria Teresa
2018-06-15
A major public health issue, Toxoplasma gondii infection can affect humans mainly via the consumption of animal products from certain species, including small ruminants. Therefore, a regular monitoring of the infection in ovine and caprine populations is advisable for the control of human and animal toxoplasmosis. Antibody detection in individual and bulk tank milk may represent a valid alternative to serological analysis, being its collection easy and not affecting animal welfare. Many serological tools for milk analysis have already been validated for several parasites, including Apicomplexa. Thus, the aim of the present study was to obtain epidemiological data on T. gondii infection through the detection of antibodies in bulk tank milk of dairy goat herds from an important area for caprine dairy production (Northern Italy). The performance of a commercial ELISA was first evaluated for analysis on caprine milk samples, using a panel of serum-milk pairs of goats naturally infected by T. gondii. The analysis on bulk tank milk confirmed the presence of antibodies anti-T. gondii in 59% of the samples. Toxoplasma gondii antibody positivity was more frequently found in farms reared under extensive (64.9%) or semi-intensive systems (68.7%) in comparison to intensive farms (51.1%). Analysis on milk revealed to be a valid alternative to serological tests, being easily applied in large-scale epidemiological surveys and for continuous monitoring of T. gondii infection.
Recent select Sample Analysis at Mars (SAM) Testbed analog results
NASA Astrophysics Data System (ADS)
Malespin, C.; McAdam, A.; Teinturier, S.; Eigenbrode, J. L.; Freissinet, C.; Knudson, C. A.; Lewis, J. M.; Millan, M.; Steele, A.; Stern, J. C.; Williams, A. J.
2017-12-01
The Sample Analysis at Mars (SAM) testbed (TB) is a high fidelity replica of the flight instrument currently onboard the Curiosity rover in Gale Crater, Mars1. The SAM testbed is housed in a Mars environment chamber at NASA Goddard Space Flight Center (GSFC), which can replicate both thermal and environmental conditions. The testbed is used to validate and test new experimental procedures before they are implemented on Mars, but it is also used to analyze analog samples which assists in the interpretation of results from the surface. Samples are heated using the same experimental protocol as on Mars to allow for direct comparison with Martian sampling conditions. Here we report preliminary results from select samples that were loaded into the SAM TB, including meteorites, an organically rich iron oxide, and a synthetic analog to the Martian Cumberland sample drilled by the rover at Yellowknife Bay. Each of these samples have been analyzed under SAM-like conditions using breadboard and lab instrument systems. By comparing the data from the lab systems and SAM TB, further insight on results from Mars can be gained. References: [1] Mahaffy, P. R., et al. (2013), Science, 341(6143), 263-266, doi:10.1126/science.1237966.
High throughput MLVA-16 typing for Brucella based on the microfluidics technology
2011-01-01
Background Brucellosis, a zoonosis caused by the genus Brucella, has been eradicated in Northern Europe, Australia, the USA and Canada, but remains endemic in most areas of the world. The strain and biovar typing of Brucella field samples isolated in outbreaks is useful for tracing back source of infection and may be crucial for discriminating naturally occurring outbreaks versus bioterrorist events, being Brucella a potential biological warfare agent. In the last years MLVA-16 has been described for Brucella spp. genotyping. The MLVA band profiles may be resolved by different techniques i.e. the manual agarose gels, the capillary electrophoresis sequencing systems or the microfluidic Lab-on-Chip electrophoresis. In this paper we described a high throughput system of MLVA-16 typing for Brucella spp. by using of the microfluidics technology. Results The Caliper LabChip 90 equipment was evaluated for MLVA-16 typing of sixty-three Brucella samples. Furthermore, in order to validate the system, DNA samples previously resolved by sequencing system and Agilent technology, were de novo genotyped. The comparison of the MLVA typing data obtained by the Caliper equipment and those previously obtained by the other analysis methods showed a good correlation. However the outputs were not accurate as the Caliper DNA fragment sizes showed discrepancies compared with real data and a conversion table from observed to expected data was created. Conclusion In this paper we described the MLVA-16 using a rapid, sophisticated microfluidics technology for detection of amplification product sizes. The comparison of the MLVA typing data produced by Caliper LabChip 90 system with the data obtained by different techniques showed a general concordance of the results. Furthermore this platform represents a significant improvement in terms of handling, data acquiring, computational efficiency and rapidity, allowing to perform the strain genotyping in a time equal to one sixth respect to other microfluidics systems as e.g. the Agilent 2100 bioanalyzer. Finally, this platform can be considered a valid alternative to standard genotyping techniques, particularly useful dealing with a large number of samples in short time. These data confirmed that this technology represents a significative advancement in high-throughput accurate Brucella genotyping. PMID:21435217
2016-09-26
placement. The preamplifier mounted on top of the headset samples EEG signals at 300 Hz; it then transmits the raw EEG data via Bluetooth ® to a data...The preamplifier mounted on the back of the headset samples EEG signals at 256 Hz and then transmits the raw EEG data via Bluetooth ® to a data...electrooculography. The batteries will last 6 hours using Bluetooth ® or 16 hours if data are recorded directly onto a secure digital card. A three-axis
Raffetti, Elena; Donato, Francesco; Pezzoli, Chiara; Digiambenedetto, Simona; Bandera, Alessandra; Di Pietro, Massimo; Di Filippo, Elisa; Maggiolo, Franco; Sighinolfi, Laura; Fornabaio, Chiara; Castelnuovo, Filippo; Ladisa, Nicoletta; Castelli, Francesco; Quiros Roldan, Eugenia
2015-08-15
Recently, some systemic inflammation-based biomarkers have been demonstrated useful for predicting risk of death in patients with solid cancer independently of tumor characteristics. This study aimed to investigate the prognostic role of systemic inflammation-based biomarkers in HIV-infected patients with solid tumors and to propose a risk score for mortality in these subjects. Clinical and pathological data on solid AIDS-defining cancer (ADC) and non-AIDS-defining cancer (NADC), diagnosed between 1998 and 2012 in an Italian cohort, were analyzed. To evaluate the prognostic role of systemic inflammation- and nutrition-based markers, univariate and multivariable Cox regression models were applied. To compute the risk score equation, the patients were randomly assigned to a derivation and a validation sample. A total of 573 patients (76.3% males) with a mean age of 46.2 years (SD = 10.3) were enrolled. 178 patients died during a median of 3.2 years of follow-up. For solid NADCs, elevated Glasgow Prognostic Score, modified Glasgow Prognostic Score, neutrophil/lymphocyte ratio, platelet/lymphocyte ratio, and Prognostic Nutritional Index were independently associated with risk of death; for solid ADCs, none of these markers was associated with risk of death. For solid NADCs, we computed a mortality risk score on the basis of age at cancer diagnosis, intravenous drug use, and Prognostic Nutritional Index. The areas under the receiver operating characteristic curve were 0.67 (95% confidence interval: 0.58 to 0.75) in the derivation sample and 0.66 (95% confidence interval: 0.54 to 0.79) in the validation sample. Inflammatory biomarkers were associated with risk of death in HIV-infected patients with solid NADCs but not with ADCs.
Armstrong, Susan M; Wither, Joan E; Borowoy, Alan M; Landolt-Marticorena, Carolina; Davis, Aileen M; Johnson, Sindhu R
2017-01-01
Case ascertainment through self-report is a convenient but often inaccurate method to collect information. The purposes of this study were to develop, assess the sensibility, and validate a tool to identify cases of systemic autoimmune rheumatic diseases (SARD) in the outpatient setting. The SARD tool was administered to subjects sampled from specialty clinics. Determinants of sensibility - comprehensibility, feasibility, validity, and acceptability - were evaluated using a numeric rating scale from 1-7. Comprehensibility was evaluated using the Flesch Reading Ease and the Flesch-Kincaid Grade Level. Self-reported diagnoses were validated against medical records using Cohen's κ statistic. There were 141 participants [systemic lupus erythematosus (SLE), systemic sclerosis (SSc), rheumatoid arthritis, Sjögren syndrome (SS), inflammatory myositis (polymyositis/dermatomyositis; PM/DM), and controls] who completed the questionnaire. The Flesch Reading Ease score was 77.1 and the Flesch-Kincaid Grade Level was 4.4. Respondents endorsed (mean ± SD) comprehensibility (6.12 ± 0.92), feasibility (5.94 ± 0.81), validity (5.35 ± 1.10), and acceptability (3.10 ± 2.03). The SARD tool had a sensitivity of 0.91 (95% CI 0.88-0.94) and a specificity of 0.99 (95% CI 0.96-1.00). The agreement between the SARD tool and medical record was κ = 0.82 (95% CI 0.77-0.88). Subgroup analysis by SARD found κ coefficients for SLE to be κ = 0.88 (95% CI 0.79-0.97), SSc κ = 1.0 (95% CI 1.0-1.0), PM/DM κ = 0.72 (95% CI 0.49-0.95), and SS κ = 0.85 (95% CI 0.71-0.99). The screening questions had sensitivity ranging from 0.96 to 1.0 and specificity ranging from 0.88 to 1.0. This SARD case ascertainment tool has demonstrable sensibility and validity. The use of both screening and confirmatory questions confers added accuracy.
Zaccardi, Francesco; Webb, David R; Davies, Melanie J; Dhalwani, Nafeesa N; Gray, Laura J; Chatterjee, Sudesna; Housley, Gemma; Shaw, Dominick; Hatton, James W; Khunti, Kamlesh
2017-06-01
Hospital admissions for hypoglycaemia represent a significant burden on individuals with diabetes and have a substantial economic impact on healthcare systems. To date, no prognostic models have been developed to predict outcomes following admission for hypoglycaemia. We aimed to develop and validate prediction models to estimate risk of inpatient death, 24 h discharge and one month readmission in people admitted to hospital for hypoglycaemia. We used the Hospital Episode Statistics database, which includes data on all hospital admission to National Health Service hospital trusts in England, to extract admissions for hypoglycaemia between 2010 and 2014. We developed, internally and temporally validated, and compared two prognostic risk models for each outcome. The first model included age, sex, ethnicity, region, social deprivation and Charlson score ('base' model). In the second model, we added to the 'base' model the 20 most common medical conditions and applied a stepwise backward selection of variables ('disease' model). We used C-index and calibration plots to assess model performance and developed a calculator to estimate probabilities of outcomes according to individual characteristics. In derivation samples, 296 out of 11,136 admissions resulted in inpatient death, 1789/33,825 in one month readmission and 8396/33,803 in 24 h discharge. Corresponding values for validation samples were: 296/10,976, 1207/22,112 and 5363/22,107. The two models had similar discrimination. In derivation samples, C-indices for the base and disease models, respectively, were: 0.77 (95% CI 0.75, 0.80) and 0.78 (0.75, 0.80) for death, 0.57 (0.56, 0.59) and 0.57 (0.56, 0.58) for one month readmission, and 0.68 (0.67, 0.69) and 0.69 (0.68, 0.69) for 24 h discharge. Corresponding values in validation samples were: 0.74 (0.71, 0.76) and 0.74 (0.72, 0.77), 0.55 (0.54, 0.57) and 0.55 (0.53, 0.56), and 0.66 (0.65, 0.67) and 0.67 (0.66, 0.68). In both derivation and validation samples, calibration plots showed good agreement for the three outcomes. We developed a calculator of probabilities for inpatient death and 24 h discharge given the low performance of one month readmission models. This simple and pragmatic tool to predict in-hospital death and 24 h discharge has the potential to reduce mortality and improve discharge in people admitted for hypoglycaemia.
When Significant Others Suffer: German Validation of the Burden Assessment Scale (BAS)
Hunger, Christina; Krause, Lena; Hilzinger, Rebecca; Ditzen, Beate; Schweitzer, Jochen
2016-01-01
There is a need of an economical, reliable, and valid instrument in the German-speaking countries to measure the burden of relatives who care for mentally ill persons. We translated the Burden Assessment Scale (BAS) and conducted a study investigating factor structure, psychometric quality and predictive validity. We used confirmative factor analyses (CFA, maximum-likelihood method) to examine the dimensionality of the German BAS in a sample of 215 relatives (72% women; M = 32 years, SD = 14, range: 18 to 77; 39% employed) of mentally ill persons (50% (ex-)partner or (best) friend; M = 32 years, SD = 13, range 8 to 64; main complaints were depression and/or anxiety). Cronbach’s α determined the internal consistency. We examined predictive validity using regression analyses including the BAS and validated scales of social systems functioning (Experience In Social Systems Questionnaire, EXIS.pers, EXIS.org) and psychopathology (Brief Symptom Inventory, BSI). Variables that might have influenced the dependent variables (e.g. age, gender, education, employment and civil status) were controlled by their introduction in the first step, and the BAS in the second step of the regression analyses. A model with four correlated factors (Disrupted Activities, Personal Distress, Time Perspective, Guilt) showed the best fit. With respect to the number of items included, the internal consistency was very good. The modified German BAS predicted relatives’ social systems functioning and psychopathology. The economical design makes the 19-item BAS promising for practice-oriented research, and for studies under time constraints. Strength, limitations and future directions are discussed. PMID:27764109
Varkey, Prathibha; Natt, Neena; Lesnick, Timothy; Downing, Steven; Yudkowsky, Rachel
2008-08-01
To determine the psychometric properties and validity of an OSCE to assess the competencies of Practice-Based Learning and Improvement (PBLI) and Systems-Based Practice (SBP) in graduate medical education. An eight-station OSCE was piloted at the end of a three-week Quality Improvement elective for nine preventive medicine and endocrinology fellows at Mayo Clinic. The stations assessed performance in quality measurement, root cause analysis, evidence-based medicine, insurance systems, team collaboration, prescription errors, Nolan's model, and negotiation. Fellows' performance in each of the stations was assessed by three faculty experts using checklists and a five-point global competency scale. A modified Angoff procedure was used to set standards. Evidence for the OSCE's validity, feasibility, and acceptability was gathered. Evidence for content and response process validity was judged as excellent by institutional content experts. Interrater reliability of scores ranged from 0.85 to 1 for most stations. Interstation correlation coefficients ranged from -0.62 to 0.99, reflecting case specificity. Implementation cost was approximately $255 per fellow. All faculty members agreed that the OSCE was realistic and capable of providing accurate assessments. The OSCE provides an opportunity to systematically sample the different subdomains of Quality Improvement. Furthermore, the OSCE provides an opportunity for the demonstration of skills rather than the testing of knowledge alone, thus making it a potentially powerful assessment tool for SBP and PBLI. The study OSCE was well suited to assess SBP and PBLI. The evidence gathered through this study lays the foundation for future validation work.
Mrazek, Michael D.; Phillips, Dawa T.; Franklin, Michael S.; Broadway, James M.; Schooler, Jonathan W.
2013-01-01
Mind-wandering is the focus of extensive investigation, yet until recently there has been no validated scale to directly measure trait levels of task-unrelated thought. Scales commonly used to assess mind-wandering lack face validity, measuring related constructs such as daydreaming or behavioral errors. Here we report four studies validating a Mind-Wandering Questionnaire (MWQ) across college, high school, and middle school samples. The 5-item scale showed high internal consistency, as well as convergent validity with existing measures of mind-wandering and related constructs. Trait levels of mind-wandering, as measured by the MWQ, were correlated with task-unrelated thought measured by thought sampling during a test of reading comprehension. In both middle school and high school samples, mind-wandering during testing was associated with worse reading comprehension. By contrast, elevated trait levels of mind-wandering predicted worse mood, less life-satisfaction, greater stress, and lower self-esteem. By extending the use of thought sampling to measure mind-wandering among adolescents, our findings also validate the use of this methodology with younger populations. Both the MWQ and thought sampling indicate that mind-wandering is a pervasive—and problematic—influence on the performance and well-being of adolescents. PMID:23986739
Renteria, Laura; Li, Susan Tinsley; Pliskin, Neil H
2008-05-01
The utility of the Spanish WAIS-III was investigated by examining its reliability and validity among 100 Spanish-speaking participants. Results indicated that the internal consistency of the subtests was satisfactory, but inadequate for Letter Number Sequencing. Criterion validity was adequate. Convergent and discriminant validity results were generally similar to the North American normative sample. Paired sample t-tests suggested that the WAIS-III may underestimate ability when compared to the criterion measures that were utilized to assess validity. This study provides support for the use of the Spanish WAIS-III in urban Hispanic populations, but also suggests that caution be used when administering specific subtests, due to the nature of the Latin America alphabet and potential test bias.
Hammam, H M; Allam, F A; Hassanein, F; El-Garby, M T
1975-01-01
Four villages in Assiut Governorate were studied. They were matched for availability and time of introduction of medical services, the size of population and the socioeconomic status. One village had a basin system of irrigation. The other three villages had perennial irrigation introduced at different dates. A sketch map of each village was made showing the location of every house and the irrigation channels. Total coverage was intended in Gezirat El-Maabda (with basin irrigation) and Nazza Karar (with perennial irrigation-recently introduced). In El-Ghorayeb and Garf Sarhan (with older systems of perennial irrigation) systematic random samples were studied. The Study included a full, double check clinical examination of urine and stools samples and a social study. Data about educational level and activities that bring the individual in contact with canal water were recorded. Tables showing the age and sex distribution of the total population and the population studied in each village are presented and show validity of the samples taken from the population.
NASA Technical Reports Server (NTRS)
Roth, Don J.; Cosgriff, Laura M.; Harder, Bryan; Zhu, Dongming; Martin, Richard E.
2013-01-01
This study investigates the applicability of a novel noncontact single-sided terahertz electromagnetic measurement method for measuring thickness in dielectric coating systems having either dielectric or conductive substrate materials. The method does not require knowledge of the velocity of terahertz waves in the coating material. The dielectric coatings ranged from approximately 300 to 1400 m in thickness. First, the terahertz method was validated on a bulk dielectric sample to determine its ability to precisely measure thickness and density variation. Then, the method was studied on simulated coating systems. One simulated coating consisted of layered thin paper samples of varying thicknesses on a ceramic substrate. Another simulated coating system consisted of adhesive-backed Teflon adhered to conducting and dielectric substrates. Alumina samples that were coated with a ceramic adhesive layer were also investigated. Finally, the method was studied for thickness measurement of actual thermal barrier coatings (TBC) on ceramic substrates. The unique aspects and limitations of this method for thickness measurements are discussed.
Gong, Zhilong; Chandler, Kiresha; Webster, Stephen; Kerley, Remy; Buist, Susan; McCort-Tipton, Melanie
2012-03-15
We report for the first time an ultra performance liquid chromatographic method with tandem mass spectrometric detection (UPLC/MS/MS) for the determination of norethindrone alone in human plasma over the concentration range of 50.0-25000 pg mL(-1) using a sample volume of 0.250 mL. Norethindrone and its internal standard (ISTD), norethindrone-(13)C(2), were extracted from human plasma by supported liquid extraction (SLE). After evaporation of the organic solvent, samples were reconstituted and analyzed on an UPLC/MS/MS system. The UPLC system used a Waters BEH C18 (100 mm × 2.1mm, 1.7 μm) column with mobile phase A of 0.05% formic acid in water:acetonitrile (65:35, v/v) and mobile phase B of 0.05% formic acid in methanol:acetonitrile (50:50, v/v). The flow rate was 0.500 mL min(-1). The method was fully validated. The inter-run accuracy and precision at the lower limit of quantitation (LLOQ), low, mid and high quality control (QC) concentration levels were 99.2-108.4% with a <8.1% CV (coefficient of variation), respectively. The validated method has been successfully applied to analysis of thousands of pharmacokinetic samples. Copyright © 2012 Elsevier B.V. All rights reserved.
Piešťanský, Juraj; Maráková, Katarína; Kovaľ, Marián; Havránek, Emil; Mikuš, Peter
2015-12-01
A new multidimensional analytical approach for the ultra-trace determination of target chiral compounds in unpretreated complex real samples was developed in this work. The proposed analytical system provided high orthogonality due to on-line combination of three different methods (separation mechanisms), i.e. (1) isotachophoresis (ITP), (2) chiral capillary zone electrophoresis (chiral CZE), and (3) triple quadrupole mass spectrometry (QqQ MS). The ITP step, performed in a large bore capillary (800 μm), was utilized for the effective sample pretreatment (preconcentration and matrix clean-up) in a large injection volume (1-10 μL) enabling to obtain as low as ca. 80 pg/mL limits of detection for the target enantiomers in urine matrices. In the chiral CZE step, the different chiral selectors (neutral, ionizable, and permanently charged cyclodextrins) and buffer systems were tested in terms of enantioselectivity and influence on the MS detection response. The performance parameters of the optimized ITP - chiral CZE-QqQ MS method were evaluated according to the FDA guidance for bioanalytical method validation. Successful validation and application (enantioselective monitoring of renally eliminated pheniramine and its metabolite in human urine) highlighted great potential of this chiral approach in advanced enantioselective biomedical applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Calibration Techniques for Accurate Measurements by Underwater Camera Systems
Shortis, Mark
2015-01-01
Calibration of a camera system is essential to ensure that image measurements result in accurate estimates of locations and dimensions within the object space. In the underwater environment, the calibration must implicitly or explicitly model and compensate for the refractive effects of waterproof housings and the water medium. This paper reviews the different approaches to the calibration of underwater camera systems in theoretical and practical terms. The accuracy, reliability, validation and stability of underwater camera system calibration are also discussed. Samples of results from published reports are provided to demonstrate the range of possible accuracies for the measurements produced by underwater camera systems. PMID:26690172
Keemei: cloud-based validation of tabular bioinformatics file formats in Google Sheets.
Rideout, Jai Ram; Chase, John H; Bolyen, Evan; Ackermann, Gail; González, Antonio; Knight, Rob; Caporaso, J Gregory
2016-06-13
Bioinformatics software often requires human-generated tabular text files as input and has specific requirements for how those data are formatted. Users frequently manage these data in spreadsheet programs, which is convenient for researchers who are compiling the requisite information because the spreadsheet programs can easily be used on different platforms including laptops and tablets, and because they provide a familiar interface. It is increasingly common for many different researchers to be involved in compiling these data, including study coordinators, clinicians, lab technicians and bioinformaticians. As a result, many research groups are shifting toward using cloud-based spreadsheet programs, such as Google Sheets, which support the concurrent editing of a single spreadsheet by different users working on different platforms. Most of the researchers who enter data are not familiar with the formatting requirements of the bioinformatics programs that will be used, so validating and correcting file formats is often a bottleneck prior to beginning bioinformatics analysis. We present Keemei, a Google Sheets Add-on, for validating tabular files used in bioinformatics analyses. Keemei is available free of charge from Google's Chrome Web Store. Keemei can be installed and run on any web browser supported by Google Sheets. Keemei currently supports the validation of two widely used tabular bioinformatics formats, the Quantitative Insights into Microbial Ecology (QIIME) sample metadata mapping file format and the Spatially Referenced Genetic Data (SRGD) format, but is designed to easily support the addition of others. Keemei will save researchers time and frustration by providing a convenient interface for tabular bioinformatics file format validation. By allowing everyone involved with data entry for a project to easily validate their data, it will reduce the validation and formatting bottlenecks that are commonly encountered when human-generated data files are first used with a bioinformatics system. Simplifying the validation of essential tabular data files, such as sample metadata, will reduce common errors and thereby improve the quality and reliability of research outcomes.
Simulation of a Geiger-Mode Imaging LADAR System for Performance Assessment
Kim, Seongjoon; Lee, Impyeong; Kwon, Yong Joon
2013-01-01
As LADAR systems applications gradually become more diverse, new types of systems are being developed. When developing new systems, simulation studies are an essential prerequisite. A simulator enables performance predictions and optimal system parameters at the design level, as well as providing sample data for developing and validating application algorithms. The purpose of the study is to propose a method for simulating a Geiger-mode imaging LADAR system. We develop simulation software to assess system performance and generate sample data for the applications. The simulation is based on three aspects of modeling—the geometry, radiometry and detection. The geometric model computes the ranges to the reflection points of the laser pulses. The radiometric model generates the return signals, including the noises. The detection model determines the flight times of the laser pulses based on the nature of the Geiger-mode detector. We generated sample data using the simulator with the system parameters and analyzed the detection performance by comparing the simulated points to the reference points. The proportion of the outliers in the simulated points reached 25.53%, indicating the need for efficient outlier elimination algorithms. In addition, the false alarm rate and dropout rate of the designed system were computed as 1.76% and 1.06%, respectively. PMID:23823970
2017-09-01
these groups . In the 2014/2015 year, efforts focused on securing a commitment from the United States Marine Corps to host the study. In Winter 2014...we can reach an adjusted sample size target in the 2017/2018 project year by expanding our recruitment to incorporate deploying infantry groups ...Vocabulary Test Revised. Circle Pines, MN: American Guidance Service. George, C. & Solomon , J. (2008). The caregving system: A behavioral systems approach
A content validated questionnaire for assessment of self reported venous blood sampling practices
2012-01-01
Background Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability. Findings We developed a questionnaire to assess deviations from best practices during venous blood sampling. The questionnaire contained questions about patient identification, test request management, test tube labeling, test tube handling, information search procedures and frequencies of error reporting. For content validity, the questionnaire was confirmed by experts on questionnaires and venous blood sampling. For reliability, test-retest statistics were used on the questionnaire answered twice. The final venous blood sampling questionnaire included 19 questions out of which 9 had in total 34 underlying items. It was found to have content validity. The test-retest analysis demonstrated that the items were generally stable. In total, 82% of the items fulfilled the reliability acceptance criteria. Conclusions The questionnaire could be used for assessment of "near miss" practices that could jeopardize patient safety and gives several benefits instead of assessing rare adverse events only. The higher frequencies of "near miss" practices allows for quantitative analysis of the effect of corrective interventions and to benchmark preanalytical quality not only at the laboratory/hospital level but also at the health care unit/hospital ward. PMID:22260505
A content validated questionnaire for assessment of self reported venous blood sampling practices.
Bölenius, Karin; Brulin, Christine; Grankvist, Kjell; Lindkvist, Marie; Söderberg, Johan
2012-01-19
Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability. We developed a questionnaire to assess deviations from best practices during venous blood sampling. The questionnaire contained questions about patient identification, test request management, test tube labeling, test tube handling, information search procedures and frequencies of error reporting. For content validity, the questionnaire was confirmed by experts on questionnaires and venous blood sampling. For reliability, test-retest statistics were used on the questionnaire answered twice. The final venous blood sampling questionnaire included 19 questions out of which 9 had in total 34 underlying items. It was found to have content validity. The test-retest analysis demonstrated that the items were generally stable. In total, 82% of the items fulfilled the reliability acceptance criteria. The questionnaire could be used for assessment of "near miss" practices that could jeopardize patient safety and gives several benefits instead of assessing rare adverse events only. The higher frequencies of "near miss" practices allows for quantitative analysis of the effect of corrective interventions and to benchmark preanalytical quality not only at the laboratory/hospital level but also at the health care unit/hospital ward.
Lievaart, Marien; Franken, Ingmar H A; Hovens, Johannes E
2016-03-01
The most commonly used instrument for measuring anger is the State-Trait Anger Expression Inventory-2 (STAXI-2; Spielberger, 1999). This study further examines the validity of the STAXI-2 and compares anger scores between several clinical and nonclinical samples. Reliability, concurrent, and construct validity were investigated in Dutch undergraduate students (N = 764), a general population sample (N = 1211), and psychiatric outpatients (N = 226). The results support the reliability and validity of the STAXI-2. Concurrent validity was strong, with meaningful correlations between the STAXI-2 scales and anger-related constructs in both clinical and nonclinical samples. Importantly, patients showed higher experience and expression of anger than the general population sample. Additionally, forensic outpatients with addiction problems reported higher Anger Expression-Out than general psychiatric outpatients. Our conclusion is that the STAXI-2 is a suitable instrument to measure both the experience and the expression of anger in both general and clinical populations. © 2016 Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Lapan, Stephen D.
The purpose of this study was to develop and validate an instrument to collect student judgments regarding their teacher's credibility. Items were developed and evidence of content validity generated. A pilot sample and a final sample of high school students were administered the Source Credibility Measure (SCM) so that actual response data could…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damiani, Rick
This manual summarizes the theory and preliminary verifications of the JacketSE module, which is an offshore jacket sizing tool that is part of the Wind-Plant Integrated System Design & Engineering Model toolbox. JacketSE is based on a finite-element formulation and on user-prescribed inputs and design standards' criteria (constraints). The physics are highly simplified, with a primary focus on satisfying ultimate limit states and modal performance requirements. Preliminary validation work included comparing industry data and verification against ANSYS, a commercial finite-element analysis package. The results are encouraging, and future improvements to the code are recommended in this manual.
Stochastic ground motion simulation
Rezaeian, Sanaz; Xiaodan, Sun; Beer, Michael; Kougioumtzoglou, Ioannis A.; Patelli, Edoardo; Siu-Kui Au, Ivan
2014-01-01
Strong earthquake ground motion records are fundamental in engineering applications. Ground motion time series are used in response-history dynamic analysis of structural or geotechnical systems. In such analysis, the validity of predicted responses depends on the validity of the input excitations. Ground motion records are also used to develop ground motion prediction equations(GMPEs) for intensity measures such as spectral accelerations that are used in response-spectrum dynamic analysis. Despite the thousands of available strong ground motion records, there remains a shortage of records for large-magnitude earthquakes at short distances or in specific regions, as well as records that sample specific combinations of source, path, and site characteristics.
Sharkey, Katherine M.; Waters, Kelly; Millman, Richard P.; Moore, Robin; Martin, Susan M.; Bourjeily, Ghada
2014-01-01
Study Objective: To assess the validity of using the Apnea Risk Evaluation System (ARES) Unicorder for detecting obstructive sleep apnea (OSA) in pregnant women. Methods: Sixteen pregnant women, mean age (SD) = 29.8 (5.4) years, average gestational age (SD) = 28.6 (6.3) weeks, mean body mass index (SD) = 44.7 (6.9) kg/m2 with signs and symptoms of OSA wore the ARES Unicorder during one night of laboratory polysomnography (PSG). PSG was scored according to AASM 2007 criteria, and PSG AHI and RDI were compared to the ARES 1%, 3%, and 4% AHIs calculated with the ARES propriety software. Results: Median PSG AHI and PSG RDI were 3.1 and 10.3 events/h of sleep, respectively. Six women had a PSG AHI ≥ 5 events/h of sleep and 11 had a PSG RDI ≥ 5 events/h of sleep. PSG AHI and RDI were strongly correlated with the ARES AHI measures. When compared with polysomnographic diagnosis of OSA, the ARES 3% algorithm provided the best balance between sensitivity (1.0 for PSG AHI, 0.91 for PSG RDI) and specificity (0.5 for PSG AHI, 0.8 for PSG RDI) for detecting sleep disordered breathing in our sample. Conclusions: The ARES Unicorder demonstrated reasonable consistency with PSG for diagnosing OSA in this small, heterogeneous sample of obese pregnant women. Citation: Sharkey KM, Waters K, Millman RP, Moore R, Martin SM, Bourjeily G. Validation of the Apnea Risk Evaluation System (ARES) device against laboratory polysomnography in pregnant women at risk for obstructive sleep apnea syndrome. J Clin Sleep Med 2014;10(5):497-502. PMID:24910550
Field calibration and validation of remote-sensing surveys
Pe'eri, Shachak; McLeod, Andy; Lavoie, Paul; Ackerman, Seth D.; Gardner, James; Parrish, Christopher
2013-01-01
The Optical Collection Suite (OCS) is a ground-truth sampling system designed to perform in situ measurements that help calibrate and validate optical remote-sensing and swath-sonar surveys for mapping and monitoring coastal ecosystems and ocean planning. The OCS system enables researchers to collect underwater imagery with real-time feedback, measure the spectral response, and quantify the water clarity with simple and relatively inexpensive instruments that can be hand-deployed from a small vessel. This article reviews the design and performance of the system, based on operational and logistical considerations, as well as the data requirements to support a number of coastal science and management projects. The OCS system has been operational since 2009 and has been used in several ground-truth missions that overlapped with airborne lidar bathymetry (ALB), hyperspectral imagery (HSI), and swath-sonar bathymetric surveys in the Gulf of Maine, southwest Alaska, and the US Virgin Islands (USVI). Research projects that have used the system include a comparison of backscatter intensity derived from acoustic (multibeam/interferometric sonars) versus active optical (ALB) sensors, ALB bottom detection, and seafloor characterization using HSI and ALB.
NASA Astrophysics Data System (ADS)
Mukherjee, S.; von der Heydt, M.; Hanson, C.; Jandura, L.
2009-12-01
The Mars Science Laboratory mission is scheduled to launch in 2011 with an extensive suite of in situ science instruments. Acquiring, processing and delivering appropriate samples of rock and martian regolith to the instruments is a critical component in realizing the science capability of these payload elements. However, there are a number of challenges in validating the design of these systems. In particular, differences in the environment (atmospheric pressure and composition, temperature, gravity), target materials (variation in rock and soil properties), and state of the hardware (electrical potential, particulate coatings) may effect sampling performance. To better understand the end-to-end system and allow development of mitigation strategies if necessary, early testing of high-fidelity engineering models of the hardware in the solid sample chain is being conducted. The components of the sample acquisition, processing & delivery chain that will be tested are the drill, scoop, sieves, portioners, and instrument inlet funnels. An evaluation of the environmental parameter space was conducted to identify a subset that may have significant effects on sampling performance and cannot be well bounded by analysis. Accordingly, support equipment to enable testing at Mars surface pressures (5-10 Torr), with carbon dioxide was designed and built. A description of the testing set-up, investigations, and preliminary results will be presented.
Body awareness and mindfulness: validation of the Spanish version of the Scale of Body Connection.
del C Quezada-Berumen, Lucía; González-Ramírez, Mónica T; Cebolla, Ausias; Soler, Joaquim; Garcia-Campayo, Javier
2014-01-01
To assess the psychometric properties and the factor structure of the Spanish version of the Scale of Body Connection (SBC) in a community population of meditators and non-meditators and to investigate the relationships among mindfulness, body awareness and body dissociation. Design. Validation study. Sampling. An internet-based commercial system was used to recruit the sample. Instruments. In addition to the SBC, the Five Facet Mindfulness Questionnaire (FFMQ) and the Depression, Anxiety, and Stress Scale (DASS-21) were administered. A sample of 578 subjects responded to all of the items in the protocol. A total of 55.2% of respondents had some previous experience with meditation. A Scree plot showed a two-factor solution involving the Body Awareness (BA) and Body Dissociation (BD) subscales. This study differed from the original validation study in the lack of independence of the subscales; they were correlated in the present study (r=-.11). Internal consistency for BA was α: .86, and for BD, the α was .62. Test-retest reliability was assessed in a subsample (N=67) and was r=.679 for BA and r=.765 for BD. Hierarchical multiple regression analyses showed that mindfulness practice and the FFMQ factors of Observing and Describing were positive predictors of BA. Describing, Acting with awareness and Non-judging negatively predicted BD, and Observing positively predicted BD. The study confirms the adequacy of the psychometric properties of the Spanish version of the SBC for use in community samples. The relationship between SBC and mindfulness is discussed in light of previous research.
Rodriguez, Adrian; Costa-Bauza, Antonia; Saez-Torres, Concepcion; Rodrigo, Dolores; Grases, Felix
2015-11-01
To validate a simple method of urinary theobromine determination, to assess urinary theobromine levels in 80 healthy children and to relate these levels to consumption of cocoa products. Urine samples were diluted, directly injected into an HPLC system, separated by gradient elution on a C18 column, and detected by UV spectrometry. The method was validated for linearity, limits of detection and quantification, imprecision, accuracy, recovery and interferences. The proposed method was used to assess 12-h day and 12-h night urinary theobromine excretion by 80 healthy children, divided into four groups based on consumption of cocoa products. In addition, urinary excretion of magnesium and oxalate, also present in cocoa, was measured in these four groups. The method was linear to a theobromine concentration of 278μmol/L (50mg/L). LOD and LOQ for urine samples, diluted 1:5 (vol/vol) with water, were 1.1 and 3.6μmol/L respectively. Within-run and between-run imprecisions (CV) were each <2%. Average recovery was 99%, and analysis of a certified reference sample showed an error <2.5%. Theobromine excretion levels were significantly higher in healthy children with higher consumption of cocoa products (p<0.001), but oxalate (p=0.098) and magnesium (p=0.068) excretion levels did not differ significantly. This validated method resulted in urinary theobromine determination with 100% recovery, without sample pretreatment. Urinary theobromine levels in healthy children were directly related to their consumption of cocoa products. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Validation of Heat Transfer Thermal Decomposition and Container Pressurization of Polyurethane Foam.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, Sarah Nicole; Dodd, Amanda B.; Larsen, Marvin E.
Polymer foam encapsulants provide mechanical, electrical, and thermal isolation in engineered systems. In fire environments, gas pressure from thermal decomposition of polymers can cause mechanical failure of sealed systems. In this work, a detailed uncertainty quantification study of PMDI-based polyurethane foam is presented to assess the validity of the computational model. Both experimental measurement uncertainty and model prediction uncertainty are examined and compared. Both the mean value method and Latin hypercube sampling approach are used to propagate the uncertainty through the model. In addition to comparing computational and experimental results, the importance of each input parameter on the simulation resultmore » is also investigated. These results show that further development in the physics model of the foam and appropriate associated material testing are necessary to improve model accuracy.« less
Use of Synchronized Phasor Measurements for Model Validation in ERCOT
NASA Astrophysics Data System (ADS)
Nuthalapati, Sarma; Chen, Jian; Shrestha, Prakash; Huang, Shun-Hsien; Adams, John; Obadina, Diran; Mortensen, Tim; Blevins, Bill
2013-05-01
This paper discusses experiences in the use of synchronized phasor measurement technology in Electric Reliability Council of Texas (ERCOT) interconnection, USA. Implementation of synchronized phasor measurement technology in the region is a collaborative effort involving ERCOT, ONCOR, AEP, SHARYLAND, EPG, CCET, and UT-Arlington. As several phasor measurement units (PMU) have been installed in ERCOT grid in recent years, phasor data with the resolution of 30 samples per second is being used to monitor power system status and record system events. Post-event analyses using recorded phasor data have successfully verified ERCOT dynamic stability simulation studies. Real time monitoring software "RTDMS"® enables ERCOT to analyze small signal stability conditions by monitoring the phase angles and oscillations. The recorded phasor data enables ERCOT to validate the existing dynamic models of conventional and/or wind generator.
The case against one-shot testing for initial dental licensure.
Chambers, David W; Dugoni, Arthur A; Paisley, Ian
2004-03-01
High-stakes testing are expected to meet standards for cost-effectiveness, fairness, transparency, high reliability, and high validity. It is questionable whether initial licensure examinations in dentistry meet such standards. Decades of piecemeal adjustments in the system have resulted in limited improvement. The essential flaw in the system is reliance on a one-shot sample of a small segment of the skills, understanding, and supporting values needed for today's professional practice of dentistry. The "snapshot" approach to testing produces inherently substandard levels of reliability and validity. A three-step alternative is proposed: boards should (1) define the competencies required of beginning practitioners, (2) establish the psychometric standards needed to make defensible judgments about candidates, and (3) base licensure decisions only on portfolios of evidence that test for defined competencies at established levels of quality.
G-DYN Multibody Dynamics Engine
NASA Technical Reports Server (NTRS)
Acikmese, Behcet; Blackmore, James C.; Broderick, Daniel
2011-01-01
G-DYN is a multi-body dynamic simulation software engine that automatically assembles and integrates equations of motion for arbitrarily connected multibody dynamic systems. The algorithm behind G-DYN is based on a primal-dual formulation of the dynamics that captures the position and velocity vectors (primal variables) of each body and the interaction forces (dual variables) between bodies, which are particularly useful for control and estimation analysis and synthesis. It also takes full advantage of the spare matrix structure resulting from the system dynamics to numerically integrate the equations of motion efficiently. Furthermore, the dynamic model for each body can easily be replaced without re-deriving the overall equations of motion, and the assembly of the equations of motion is done automatically. G-DYN proved an essential software tool in the simulation of spacecraft systems used for small celestial body surface sampling, specifically in simulating touch-and-go (TAG) maneuvers of a robotic sampling system from a comet and asteroid. It is used extensively in validating mission concepts for small body sample return, such as Comet Odyssey and Galahad New Frontiers proposals.
NASA Astrophysics Data System (ADS)
Evans, M. N.; Selmer, K. J.; Breeden, B. T.; Lopatka, A. S.; Plummer, R. E.
2016-09-01
We describe an algorithm to correct for scale compression, runtime drift, and amplitude effects in carbonate and cellulose oxygen and carbon isotopic analyses made on two online continuous flow isotope ratio mass spectrometry (CF-IRMS) systems using gas chromatographic (GC) separation. We validate the algorithm by correcting measurements of samples of known isotopic composition which are not used to estimate the corrections. For carbonate δ13C (δ18O) data, median precision of validation estimates for two reference materials and two calibrated working standards is 0.05‰ (0.07‰); median bias is 0.04‰ (0.02‰) over a range of 49.2‰ (24.3‰). For α-cellulose δ13C (δ18O) data, median precision of validation estimates for one reference material and five working standards is 0.11‰ (0.27‰); median bias is 0.13‰ (-0.10‰) over a range of 16.1‰ (19.1‰). These results are within the 5th-95th percentile range of subsequent routine runtime validation exercises in which one working standard is used to calibrate the other. Analysis of the relative importance of correction steps suggests that drift and scale-compression corrections are most reliable and valuable. If validation precisions are not already small, routine cross-validated precision estimates are improved by up to 50% (80%). The results suggest that correction for systematic error may enable these particular CF-IRMS systems to produce δ13C and δ18O carbonate and cellulose isotopic analyses with higher validated precision, accuracy, and throughput than is typically reported for these systems. The correction scheme may be used in support of replication-intensive research projects in paleoclimatology and other data-intensive applications within the geosciences.
Andreis, Elisabeth; Küllmer, Kai
2014-01-01
Self-monitoring of blood glucose (BG) by means of handheld BG systems is a cornerstone in diabetes therapy. The aim of this article is to describe a procedure with proven traceability for calibration and evaluation of BG systems to guarantee reliable BG measurements. Isotope dilution gas chromatography mass spectrometry (ID/GC/MS) is a method that fulfills all requirements to be used in a higher-order reference measurement procedure. However, this method is not applicable for routine measurements because of the time-consuming sample preparation. A hexokinase method with perchloric acid (PCA) sample pretreatment is used in a measurement procedure for such purposes. This method is directly linked to the ID/GC/MS method by calibration with a glucose solution that has an ID/GC/MS-determined target value. BG systems are calibrated with whole blood samples. The glucose levels in such samples are analyzed by this ID/GC/MS-linked hexokinase method to establish traceability to higher-order reference material. For method comparison, the glucose concentrations in 577 whole blood samples were measured using the PCA-hexokinase method and the ID/GC/MS method; this resulted in a mean deviation of 0.1%. The mean deviation between BG levels measured in >500 valid whole blood samples with BG systems and the ID/GC/MS was 1.1%. BG systems allow a reliable glucose measurement if a true reference measurement procedure, with a noninterrupted traceability chain using ID/GC/MS linked hexokinase method for calibration of BG systems, is implemented. Systems should be calibrated by means of a traceable and defined measurement procedure to avoid bias. PMID:24876614
Chang, Hsiu-Ju; Wu, Chiung-Jane; Chen, Tzen Wen; Cheng, Andrew Tai Ann; Lin, Kuan-Chia; Rong, Jiin-Ru; Lee, Hsin-Chien
2011-05-01
Although prior research has proposed that several risk factors are conceptually and positively related to suicidal behavior, researchers have also suggested that suicide may be multifaceted. The Life Attitude Schedule (LAS) measures a broad range of suicide-related behaviors, including life-enhancing and life-threatening behaviors. This study aimed to translate the LAS into Chinese and evaluate the psychometric properties of the new version (LAS-C). A cross-sectional and descriptive design was used. Data were collected from high schools in the city of Taipei in northern Taiwan. A convenience sample of 1492 high school students was recruited from five high schools in Taipei. We used the Multi-Health Systems (MHS) translation policy to guide the translation process. Reliability was evaluated by internal consistency (represented by Cronbach's α coefficients) and test-retest (represented by intraclass correlation). Validity was demonstrated by content, convergent, divergent, concurrent, and contrast group comparison. Confirmatory factor analysis was further used to examine the theoretical model and to support construct validity. The Cronbach's α coefficient for the whole scale of the LAS-C and its subscales ranged from 0.70 to 0.91. The Intraclass Correlation Coefficient (ICC) ranged from 0.76 to 0.89 on the whole scale and its subscales, and were all statistically significant, at least at the p<0.05 level, indicating good stability over a three-week period. Validity was supported by a Content Validity Index (CVI) of 0.99, convergent, divergent, current, and contrast group comparison validity. Confirmatory factor analysis supported the theoretical model, further providing solid evidence of construct validity. The LAS-C has proper psychometric properties. Future studies must be conducted to shorten the items to form a briefer version. Copyright © 2010 Elsevier Ltd. All rights reserved.
Schnall, Rebecca; Cho, Hwayoung; Liu, Jianfang
2018-01-05
Mobile technology has become a ubiquitous technology and can be particularly useful in the delivery of health interventions. This technology can allow us to deliver interventions to scale, cover broad geographic areas, and deliver technologies in highly tailored ways based on the preferences or characteristics of users. The broad use of mobile technologies supports the need for usability assessments of these tools. Although there have been a number of usability assessment instruments developed, none have been validated for use with mobile technologies. The goal of this work was to validate the Health Information Technology Usability Evaluation Scale (Health-ITUES), a customizable usability assessment instrument in a sample of community-dwelling adults who were testing the use of a new mobile health (mHealth) technology. A sample of 92 community-dwelling adults living with HIV used a new mobile app for symptom self-management and completed the Health-ITUES to assess the usability of the app. They also completed the Post-Study System Usability Questionnaire (PSSUQ), a widely used and well-validated usability assessment tool. Correlations between these scales and each of the subscales were assessed. The subscales of the Health-ITUES showed high internal consistency reliability (Cronbach alpha=.85-.92). Each of the Health-ITUES subscales and the overall scale was moderately to strongly correlated with the PSSUQ scales (r=.46-.70), demonstrating the criterion validity of the Health-ITUES. The Health-ITUES has demonstrated reliability and validity for use in assessing the usability of mHealth technologies in community-dwelling adults living with a chronic illness. ©Rebecca Schnall, Hwayoung Cho, Jianfang Liu. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 05.01.2018.
Cho, Hwayoung; Liu, Jianfang
2018-01-01
Background Mobile technology has become a ubiquitous technology and can be particularly useful in the delivery of health interventions. This technology can allow us to deliver interventions to scale, cover broad geographic areas, and deliver technologies in highly tailored ways based on the preferences or characteristics of users. The broad use of mobile technologies supports the need for usability assessments of these tools. Although there have been a number of usability assessment instruments developed, none have been validated for use with mobile technologies. Objective The goal of this work was to validate the Health Information Technology Usability Evaluation Scale (Health-ITUES), a customizable usability assessment instrument in a sample of community-dwelling adults who were testing the use of a new mobile health (mHealth) technology. Methods A sample of 92 community-dwelling adults living with HIV used a new mobile app for symptom self-management and completed the Health-ITUES to assess the usability of the app. They also completed the Post-Study System Usability Questionnaire (PSSUQ), a widely used and well-validated usability assessment tool. Correlations between these scales and each of the subscales were assessed. Results The subscales of the Health-ITUES showed high internal consistency reliability (Cronbach alpha=.85-.92). Each of the Health-ITUES subscales and the overall scale was moderately to strongly correlated with the PSSUQ scales (r=.46-.70), demonstrating the criterion validity of the Health-ITUES. Conclusions The Health-ITUES has demonstrated reliability and validity for use in assessing the usability of mHealth technologies in community-dwelling adults living with a chronic illness. PMID:29305343
Beyond Corroboration: Strengthening Model Validation by Looking for Unexpected Patterns
Chérel, Guillaume; Cottineau, Clémentine; Reuillon, Romain
2015-01-01
Models of emergent phenomena are designed to provide an explanation to global-scale phenomena from local-scale processes. Model validation is commonly done by verifying that the model is able to reproduce the patterns to be explained. We argue that robust validation must not only be based on corroboration, but also on attempting to falsify the model, i.e. making sure that the model behaves soundly for any reasonable input and parameter values. We propose an open-ended evolutionary method based on Novelty Search to look for the diverse patterns a model can produce. The Pattern Space Exploration method was tested on a model of collective motion and compared to three common a priori sampling experiment designs. The method successfully discovered all known qualitatively different kinds of collective motion, and performed much better than the a priori sampling methods. The method was then applied to a case study of city system dynamics to explore the model’s predicted values of city hierarchisation and population growth. This case study showed that the method can provide insights on potential predictive scenarios as well as falsifiers of the model when the simulated dynamics are highly unrealistic. PMID:26368917
An Investigation Into HPLC Data Quality Problems
NASA Technical Reports Server (NTRS)
Hooker, Stanford B.; VanHeukelem, Laurie
2011-01-01
This report summarizes the analyses and results produced by a five-member investigative team of Government, university, and industry experts, established by NASA HQ. The team examined data quality problems associated with high performance liquid chromatography (HPLC) analyses of pigment concentrations in seawater samples produced by the San Diego State University (SDSU) Center for Hydro-Optics and Remote Sensing (CHORS). This report shows CHORS did not validate the methods used before placing them into service to analyze field samples for NASA principal investigators (PIs), even though the HPLC literature contained easily accessible method validation procedures, and the importance of implementing them, more than a decade ago. In addition, there were so many sources of significant variance in the CHORS methodologies, that the HPLC system rarely operated within performance criteria capable of producing the requisite data quality. It is the recommendation of the investigative team to a) not correct the data, b) make all the data that was temporarily sequestered available for scientific use, and c) label the affected data with an appropriate warning, e.g., "These data are not validated and should not be used as the sole basis for a scientific result, conclusion, or hypothesis--independent corroborating evidence is required."
Carlier, Mieke; Stove, Veronique; Roberts, Jason A; Van de Velde, Eric; De Waele, Jan J; Verstraete, Alain G
2012-11-01
There is an increasing interest in monitoring plasma concentrations of β-lactam antibiotics. The objective of this work was to develop and validate a rapid ultra-performance liquid chromatographic method with tandem mass spectrometric detection (UPLC-MS/MS) for simultaneous quantification of amoxicillin, ampicillin, cefuroxime, cefazolin, ceftazidime, meropenem, piperacillin, clavulanic acid and tazobactam. Sample clean-up included protein precipitation with acetonitrile and back-extraction of acetonitrile with dichloromethane. Six deuterated β-lactam antibiotics were used as internal standards. Chromatographic separation was performed on a Waters ACQUITY UPLC system using a BEH C(18) column (1.7 μm, 100 mm×2.1 mm) applying a binary gradient elution of water and acetonitrile both containing 0.1% formic acid. The total run time was 5.5 min. The developed method was validated in terms of precision, accuracy, linearity, matrix effect and recovery. The assay has now been successfully used to determine concentrations of amoxicillin/clavulanic acid, cefuroxime and meropenem in plasma samples from intensive care patients. Copyright © 2012 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.
Belete, Tamrat; Crowley, Erin; Bird, Patrick; Gensic, Joseph; Wallace, F Morgan
2014-10-01
The performances of two DuPont BAX System PCR assays for detecting Salmonella on a variety of low-moisture soy ingredients were evaluated against the U. S. Food and Drug Administration's Bacteriological Analytical Manual (FDA BAM) method or the International Organization for Standardization (ISO) 6579 reference method. These evaluations were conducted as a single laboratory validation at an ISO 17025 accredited third-party laboratory. Validations were conducted on five soy ingredients: isolated soy protein (ISP), soy fiber, fluid soy lecithin, deoiled soy lecithin, and soy nuggets, using a paired-study design. The ISP was analyzed as both 25- and 375-g composite test portions, whereas all other sample matrices were analyzed as 375-g composite test portions. To evaluate 25-g test portions of ISP, the test material was inoculated using Salmonella enterica subsp. enterica serovar Mbandaka (Q Laboratories isolate 11031.1). Salmonella enterica subsp. enterica serovar Tennessee (Q Laboratories isolate 11031.3) was used for all other trials. For each trial of the method comparison, 25 samples were analyzed for each matrix: 5 uninoculated controls and 20 samples inoculated at low levels (0.2 to 2 CFU per test portion) that were targeted to achieve fractionally positive results (25 to 75%). Using McNemar's chi-square analysis, no significant difference at P ≥ 0.05 (χ(2) ≤ 3.84) was observed between the number of positives obtained by the BAX System and the reference methods for all five test matrices evaluated. These studies indicate that the BAX System PCR assays, in combination with the single buffered peptone water primary enrichment and subsequent brain heart infusion regrowth step, demonstrate equivalent sensitivity and robustness compared with the FDA BAM and ISO reference methods for both 25- and 375-g composite samples. Moreover, there was no observed reduction of sensitivity in the larger 375-g composite samples for all five matrices.
Halter, Ryan J; Zhou, Tian; Meaney, Paul M; Hartov, Alex; Barth, Richard J; Rosenkranz, Kari M; Wells, Wendy A; Kogel, Christine A; Borsic, Andrea; Rizzo, Elizabeth J; Paulsen, Keith D
2009-01-01
Electromagnetic (EM) breast imaging provides low-cost, safe and potentially a more specific modality for cancer detection than conventional imaging systems. A primary difficulty in validating these EM imaging modalities is that the true dielectric property values of the particular breast being imaged are not readily available on an individual subject basis. Here, we describe our initial experience in seeking to correlate tomographic EM imaging studies with discrete point spectroscopy measurements of the dielectric properties of breast tissue. The protocol we have developed involves measurement of in vivo tissue properties during partial and full mastectomy procedures in the operating room (OR) followed by ex vivo tissue property recordings in the same locations in the excised tissue specimens in the pathology laboratory immediately after resection. We have successfully applied all of the elements of this validation protocol in a series of six women with cancer diagnoses. Conductivity and permittivity gauged from ex vivo samples over the frequency range 100 Hz–8.5 GHz are found to be similar to those reported in the literature. A decrease in both conductivity and permittivity is observed when these properties are gauged from ex vivo samples instead of in vivo. We present these results in addition to a case study demonstrating how discrete point spectroscopy measurements of the tissue can be correlated and used to validate EM imaging studies. PMID:19491436
Validity of histopathological grading of articular cartilage from osteoarthritic knee joints
Ostergaard, K.; Andersen, C.; Petersen, J.; Bendtzen, K.; Salter, D.
1999-01-01
OBJECTIVES—To determine the validity of the histological-histochemical grading system (HHGS) for osteoarthritic (OA) articular cartilage. METHODS—Human articular cartilage was obtained from macroscopically normal (n = 13) and OA (n = 21) knee joints. Sections of central and peripheral regions of normal samples were produced. Sections of regions containing severe, moderate, and mild OA changes were produced from each OA sample. A total of 89 sections were graded by means of the HHGS (0-14) twice by three observers. RESULTS—Average scores for regions designated severe (8.64) and moderate (5.83) OA were less than the expected (10-14 and 6-9, respectively) according to the HHGS, whereas average scores for the region designated mild (5.29) OA and central and peripheral regions (2.19) of normal cartilage were higher than expected (2-5 and 0-1, respectively). The HHGS was capable of differentiating between articular cartilage from macroscopically normal and OA joints and between the region designated severe OA and other regions. However, the HHGS did not adequately differentiate between regions designated mild and moderate OA. Values for sensitivity, specificity, and efficiency for all regions varied considerably. CONCLUSION—The HHGS is valid for normal and severe OA cartilage, but does not permit distinction between mild and moderate OA changes in articular cartilage. Keywords: histopathology; osteoarthritis; reliability; validity PMID:10364898
Mucci, A; Galderisi, S; Merlotti, E; Rossi, A; Rocca, P; Bucci, P; Piegari, G; Chieffi, M; Vignapiano, A; Maj, M
2015-07-01
The Brief Negative Symptom Scale (BNSS) was developed to address the main limitations of the existing scales for the assessment of negative symptoms of schizophrenia. The initial validation of the scale by the group involved in its development demonstrated good convergent and discriminant validity, and a factor structure confirming the two domains of negative symptoms (reduced emotional/verbal expression and anhedonia/asociality/avolition). However, only relatively small samples of patients with schizophrenia were investigated. Further independent validation in large clinical samples might be instrumental to the broad diffusion of the scale in clinical research. The present study aimed to examine the BNSS inter-rater reliability, convergent/discriminant validity and factor structure in a large Italian sample of outpatients with schizophrenia. Our results confirmed the excellent inter-rater reliability of the BNSS (the intraclass correlation coefficient ranged from 0.81 to 0.98 for individual items and was 0.98 for the total score). The convergent validity measures had r values from 0.62 to 0.77, while the divergent validity measures had r values from 0.20 to 0.28 in the main sample (n=912) and in a subsample without clinically significant levels of depression and extrapyramidal symptoms (n=496). The BNSS factor structure was supported in both groups. The study confirms that the BNSS is a promising measure for quantifying negative symptoms of schizophrenia in large multicenter clinical studies. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Stevens, Andreas; Bahlo, Simone; Licha, Christina; Liske, Benjamin; Vossler-Thies, Elisabeth
2016-11-30
Subnormal performance in attention tasks may result from various sources including lack of effort. In this report, the derivation and validation of a performance validity parameter for reaction time is described, using a set of malingering-indices ("Slick-criteria"), and 3 independent samples of participants (total n =893). The Slick-criteria yield an estimate of the probability of malingering based on the presence of an external incentive, evidence from neuropsychological testing, from self-report and clinical data. In study (1) a validity parameter is derived using reaction time data of a sample, composed of inpatients with recent severe brain lesions not involved in litigation and of litigants with and without brain lesion. In study (2) the validity parameter is tested in an independent sample of litigants. In study (3) the parameter is applied to an independent sample comprising cooperative and non-cooperative testees. Logistic regression analysis led to a derived validity parameter based on median reaction time and standard deviation. It performed satisfactorily in studies (2) and (3) (study 2 sensitivity=0.94, specificity=1.00; study 3 sensitivity=0.79, specificity=0.87). The findings suggest that median reaction time and standard deviation may be used as indicators of negative response bias. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Li, Chengshuai; Chen, Shichao; Klemba, Michael; Zhu, Yizheng
2016-09-01
A dual-modality birefringence/phase imaging system is presented. The system features a crystal retarder that provides polarization mixing and generates two interferometric carrier waves in a single signal spectrum. The retardation and orientation of sample birefringence can then be measured simultaneously based on spectral multiplexing interferometry. Further, with the addition of a Nomarski prism, the same setup can be used for quantitative differential interference contrast (DIC) imaging. Sample phase can then be obtained with two-dimensional integration. In addition, birefringence-induced phase error can be corrected using the birefringence data. This dual-modality approach is analyzed theoretically with Jones calculus and validated experimentally with malaria-infected red blood cells. The system generates not only corrected DIC and phase images, but a birefringence map that highlights the distribution of hemozoin crystals.
NASA Astrophysics Data System (ADS)
Li, Chengshuai; Chen, Shichao; Klemba, Michael; Zhu, Yizheng
2016-09-01
A dual-modality birefringence/phase imaging system is presented. The system features a crystal retarder that provides polarization mixing and generates two interferometric carrier waves in a single signal spectrum. The retardation and orientation of sample birefringence can then be measured simultaneously based on spectral multiplexing interferometry. Further, with the addition of a Nomarski prism, the same setup can be used for quantitative differential interference contrast (DIC) imaging. Sample phase can then be obtained with two-dimensional integration. In addition, birefringence-induced phase error can be corrected using the birefringence data. This dual-modality approach is analyzed theoretically with Jones calculus and validated experimentally with malaria-infected red blood cells. The system generates not only corrected DIC and phase images, but a birefringence map that highlights the distribution of hemozoin crystals.
Suzuki, T; Sato, Y; Sotome, S; Arai, H; Arai, A; Yoshida, H
2017-06-01
This study was designed to investigate the reliability and validity of measurements of finger diameters with a ring gauge. A reliability study enrolled two independent samples (50 participants and seven examiners in Study I; 26 participants and 26 examiners in Study II). The sizes of each participant's little fingers were measured twice with a ring gauge by each examiner. To investigate the validity of the measurements, five hand therapists compared the finger size and hand volume of 30 participants with the ring gauge and with a figure-of-eight technique (Study III). The intra-class correlation coefficient for intra-observer reliability ranged from 0.97 to 0.99 in Study I, and 0.90 to 0.97 in Study II. The intra-class correlation coefficient for inter-observer reliability was 0.95 in Study I and 0.94 in Study II. The validity study showed a Pearson product moment correlation coefficient of 0.75. The ring gauge showed high reliability and validity for measurement of finger size. III, diagnostic.
An integrated bioanalytical method development and validation approach: case studies.
Xue, Y-J; Melo, Brian; Vallejo, Martha; Zhao, Yuwen; Tang, Lina; Chen, Yuan-Shek; Keller, Karin M
2012-10-01
We proposed an integrated bioanalytical method development and validation approach: (1) method screening based on analyte's physicochemical properties and metabolism information to determine the most appropriate extraction/analysis conditions; (2) preliminary stability evaluation using both quality control and incurred samples to establish sample collection, storage and processing conditions; (3) mock validation to examine method accuracy and precision and incurred sample reproducibility; and (4) method validation to confirm the results obtained during method development. This integrated approach was applied to the determination of compound I in rat plasma and compound II in rat and dog plasma. The effectiveness of the approach was demonstrated by the superior quality of three method validations: (1) a zero run failure rate; (2) >93% of quality control results within 10% of nominal values; and (3) 99% incurred sample within 9.2% of the original values. In addition, rat and dog plasma methods for compound II were successfully applied to analyze more than 900 plasma samples obtained from Investigational New Drug (IND) toxicology studies in rats and dogs with near perfect results: (1) a zero run failure rate; (2) excellent accuracy and precision for standards and quality controls; and (3) 98% incurred samples within 15% of the original values. Copyright © 2011 John Wiley & Sons, Ltd.
Oxygen consumption of keloids and hypertrophic scars.
Ichioka, Shigeru; Ando, Taichi; Shibata, Masahiro; Sekiya, Naomi; Nakatsuka, Takashi
2008-02-01
The oxygen consumption of keloids and hypertrophic scars has never been quantitatively presented, although abnormal metabolic conditions must be associated with their pathophysiology. We invented an original measurement system equipped with a Clark oxygen electrode for ex vivo samples. The measurement of a mouse wound-healing model revealed immature repairing tissues consumed more oxygen than mature tissues. This finding is in accord with the current thinking and supported the validity of our measurement system. The analysis of fresh human samples clearly demonstrated the high oxygen consumption rate of keloid hypertrophic scars and the comparatively low consumption of mature scars. A high oxygen consuming potential, as well as insufficient oxygen diffusion, may possibly contribute to the pathophysiology of keloids and hypertrophic scars.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Linard, Joshua; Campbell, Sam
This event included annual sampling of groundwater and surface water locations at the Gunnison, Colorado, Processing Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for US Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and analysis-plan-us-department-energy-office-legacy-management-sites). Samples were collected from 28 monitoring wells, three domestic wells, and six surface locations in April at the processing site as specified in the draft 2010 Ground Water Compliance Action Plan for the Gunnison, Colorado, Processing Site. Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. Domestic wells 0476 and 0477 weremore » sampled in June because the homes were unoccupied in April, and the wells were not in use. Duplicate samples were collected from locations 0126, 0477, and 0780. One equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. See Attachment 2, Trip Reports for additional details. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. No issues were identified during the data validation process that requires additional action or follow-up. An assessment of anomalous data is included in Attachment 3. Interpretation and presentation of results, including an assessment ofthe natural flushing compliance strategy, will be reported in the upcoming 2016 Verification Monitoring Report. U.S.« less
LeBeau, Richard T; Mesri, Bita; Craske, Michelle G
2016-10-30
With DSM-5, the APA began providing guidelines for anxiety disorder severity assessment that incorporates newly developed self-report scales. The scales share a common template, are brief, and are free of copyright restrictions. Initial validation studies have been promising, but the English-language versions of the scales have not been formally validated in clinical samples. Forty-seven individuals with a principal diagnosis of Social Anxiety Disorder (SAD) completed a diagnostic assessment, as well as the DSM-5 SAD severity scale and several previously validated measures. The scale demonstrated internal consistency, convergent validity, and discriminant validity. The next steps in the validation process are outlined. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Soble, Jason R; Bain, Kathleen M; Bailey, K Chase; Kirton, Joshua W; Marceaux, Janice C; Critchfield, Edan A; McCoy, Karin J M; O'Rourke, Justin J F
2018-01-08
Embedded performance validity tests (PVTs) allow for continuous assessment of invalid performance throughout neuropsychological test batteries. This study evaluated the utility of the Wechsler Memory Scale-Fourth Edition (WMS-IV) Logical Memory (LM) Recognition score as an embedded PVT using the Advanced Clinical Solutions (ACS) for WAIS-IV/WMS-IV Effort System. This mixed clinical sample was comprised of 97 total participants, 71 of whom were classified as valid and 26 as invalid based on three well-validated, freestanding criterion PVTs. Overall, the LM embedded PVT demonstrated poor concordance with the criterion PVTs and unacceptable psychometric properties using ACS validity base rates (42% sensitivity/79% specificity). Moreover, 15-39% of participants obtained an invalid ACS base rate despite having a normatively-intact age-corrected LM Recognition total score. Receiving operating characteristic curve analysis revealed a Recognition total score cutoff of < 61% correct improved specificity (92%) while sensitivity remained weak (31%). Thus, results indicated the LM Recognition embedded PVT is not appropriate for use from an evidence-based perspective, and that clinicians may be faced with reconciling how a normatively intact cognitive performance on the Recognition subtest could simultaneously reflect invalid performance validity.
Li, Xiaochuan; Bai, Xuedong; Wu, Yaohong; Ruan, Dike
2016-03-15
To construct and validate a model to predict responsible nerve roots in lumbar degenerative disease with diagnostic doubt (DD). From January 2009-January 2013, 163 patients with DD were assigned to the construction (n = 106) or validation sample (n = 57) according to different admission times to hospital. Outcome was assessed according to the Japanese Orthopedic Association (JOA) recovery rate as excellent, good, fair, and poor. The first two results were considered as effective clinical outcome (ECO). Baseline patient and clinical characteristics were considered as secondary variables. A multivariate logistic regression model was used to construct a model with the ECO as a dependent variable and other factors as explanatory variables. The odds ratios (ORs) of each risk factor were adjusted and transformed into a scoring system. Area under the curve (AUC) was calculated and validated in both internal and external samples. Moreover, calibration plot and predictive ability of this scoring system were also tested for further validation. Patients with DD with ECOs in both construction and validation models were around 76 % (76.4 and 75.5 % respectively). more preoperative visual analog pain scale (VAS) score (OR = 1.56, p < 0.01), stenosis levels of L4/5 or L5/S1 (OR = 1.44, p = 0.04), stenosis locations with neuroforamen (OR = 1.95, p = 0.01), neurological deficit (OR = 1.62, p = 0.01), and more VAS improvement of selective nerve route block (SNRB) (OR = 3.42, p = 0.02). the internal area under the curve (AUC) was 0.85, and the external AUC was 0.72, with a good calibration plot of prediction accuracy. Besides, the predictive ability of ECOs was not different from the actual results (p = 0.532). We have constructed and validated a predictive model for confirming responsible nerve roots in patients with DD. The associated risk factors were preoperative VAS score, stenosis levels of L4/5 or L5/S1, stenosis locations with neuroforamen, neurological deficit, and VAS improvement of SNRB. A tool such as this is beneficial in the preoperative counseling of patients, shared surgical decision making, and ultimately improving safety in spine surgery.
Development and validation of an Argentine set of facial expressions of emotion.
Vaiman, Marcelo; Wagner, Mónica Anna; Caicedo, Estefanía; Pereno, Germán Leandro
2017-02-01
Pictures of facial expressions of emotion are used in a wide range of experiments. The last decade has seen an increase in the number of studies presenting local sets of emotion stimuli. However, only a few existing sets contain pictures of Latin Americans, despite the growing attention emotion research is receiving in this region. Here we present the development and validation of the Universidad Nacional de Cordoba, Expresiones de Emociones Faciales (UNCEEF), a Facial Action Coding System (FACS)-verified set of pictures of Argentineans expressing the six basic emotions, plus neutral expressions. FACS scores, recognition rates, Hu scores, and discrimination indices are reported. Evidence of convergent validity was obtained using the Pictures of Facial Affect in an Argentine sample. However, recognition accuracy was greater for UNCEEF. The importance of local sets of emotion pictures is discussed.
A Comprehensive Validation Approach Using The RAVEN Code
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alfonsi, Andrea; Rabiti, Cristian; Cogliati, Joshua J
2015-06-01
The RAVEN computer code , developed at the Idaho National Laboratory, is a generic software framework to perform parametric and probabilistic analysis based on the response of complex system codes. RAVEN is a multi-purpose probabilistic and uncertainty quantification platform, capable to communicate with any system code. A natural extension of the RAVEN capabilities is the imple- mentation of an integrated validation methodology, involving several different metrics, that represent an evolution of the methods currently used in the field. The state-of-art vali- dation approaches use neither exploration of the input space through sampling strategies, nor a comprehensive variety of metrics neededmore » to interpret the code responses, with respect experimental data. The RAVEN code allows to address both these lacks. In the following sections, the employed methodology, and its application to the newer developed thermal-hydraulic code RELAP-7, is reported.The validation approach has been applied on an integral effect experiment, representing natu- ral circulation, based on the activities performed by EG&G Idaho. Four different experiment configurations have been considered and nodalized.« less
NASA Astrophysics Data System (ADS)
Zhang, Jun; Dong, Chengcheng; Zhang, Hui; Li, Song; Song, Aiguo
2018-05-01
This paper presents a novel lander anchoring system based on sawing method for asteroid exploration. The system is composed of three robotic arms, three cutting discs, and a control system. The discs mounted at the end of the arms are able to penetrate into the rock surface of asteroids. After the discs cut into the rock surface, the self-locking function of the arms provides forces to fix the lander on the surface. Modeling, trajectory planning, simulations, mechanism design, and prototype fabrication of the anchoring system are discussed, respectively. The performances of the system are tested on different kinds of rocks, at different sawing angles, locations, and speeds. Results show that the system can cut 15 mm deep into granite rock in 180 s at sawing angle of 60°, with the average power of 58.41 W, and the "weight on bit" (WOB) of 8.637 N. The 7.8 kg anchoring system is capable of providing omni-directional anchoring forces, at least 225 N normal and 157 N tangent to the surface of the rock. The system has the advantages of low-weight, low energy consumption and balance forces, high anchoring efficiency and reliability, and could enable the lander to move and sample or assist astronauts and robots in walking and sampling on asteroids.
NASA Astrophysics Data System (ADS)
Blaber, Elizabeth; Dvorochkin, Natalya; Almeida, Eduardo; Fitzpatrick, Garret; Ellingson, Lance; Mitchell, Sarah; Yang, Anthony; Kosnik, Cristine; Rayl, Nicole; Cannon, Tom; Austin, Edward; Sato, Kevin
With the recent call by the 2011 Decadal Report and the 2010 Space Biosciences Roadmap for the International Space Station (ISS) to be used as a National Laboratory for scientific research, there is now a need for new laboratory instruments on ISS to enable such research to occur. The Bioculture System supports the extended culturing of multiple cell types and microbiological specimens. It consists of a docking station that carries ten independent incubation units or ‘Cassettes’. Each Cassette contains a cooling chamber (5(°) C) for temperature sensitive solutions and samples, or long duration fluids and sample storage, as well as an incubation chamber (ambient up to 42(°) C). Each Cassette houses an independent fluidics system comprised of a biochamber, medical-grade fluid tubing, medium warming module, oxygenation module, fluid pump, and sixteen solenoid valves for automated biochamber injections of sampling. The Bioculture System provides the user with the ability to select the incubation temperature, fluid flow rate and automated biochamber sampling or injection events for each separate Cassette. Furthermore, the ISS crew can access the biochamber, media bag, and accessory bags on-orbit using the Microgravity Science Glovebox. The Bioculture System also permits initiation of cultures, subculturing, injection of compounds, and removal of samples for on-orbit processing using ISS facilities. The Bioculture System therefore provides a unique opportunity for the study of stem cells and other cell types in space. The first validation flight of the Bioculture System will be conducted on SpaceX5, consisting of 8 Cassettes and lasting for 30-37 days. During this flight we plan to culture two different mammalian cell types in bioreactors: a mouse osteocytic-like cell line, and human induced pluripotent stem cell (iPS)-derived cardiomyocytes. Specifically, the osteocytic line will enable the study of a type of cell that has been flown on the Bioculture System’s predecessor, the Cell Culture Module, whilst demonstrating the Bioculture Systems bead-based sub-culturing capabilities, automated sampling and fixation, manual sample removal/storage by ISS crew members, and whole bioreactor fixation. These activities will enable, for the first time, the long-duration culture of a proliferative cell line. Furthermore, these activities will facilitate genetic and proteomic analysis of these cells at several time points to determine cell health throughout the culture period. The long-duration culture of iPS-derived cardiomyocytes will afford us the capability to assess the maturation and formation of a cardiac-like tissue in microgravity conditions. Automated sampling of this culture immediately prior to un-berthing from the ISS will enable genetic analysis of the mature cardiomyocyte tissue, whilst still enabling the return of live cultures for analysis of cardiomyocyte morphology, contractility, and viability in response to spaceflight. This validation flight will demonstrate the new functional capabilities of the Bioculture System and the System will enable, for the first time, the study of the response of stem cells and other cell lineages to long-duration spaceflight exposure, whilst enabling normal cell culturing techniques to be automatically conducted on ISS.
Jackson, T
2001-05-01
Casemix-funding systems for hospital inpatient care require a set of resource weights which will not inadvertently distort patterns of patient care. Few health systems have very good sources of cost information, and specific studies to derive empirical cost relativities are themselves costly. This paper reports a 5 year program of research into the use of data from hospital management information systems (clinical costing systems) to estimate resource relativities for inpatient hospital care used in Victoria's DRG-based payment system. The paper briefly describes international approaches to cost weight estimation. It describes the architecture of clinical costing systems, and contrasts process and job costing approaches to cost estimation. Techniques of data validation and reliability testing developed in the conduct of four of the first five of the Victorian Cost Weight Studies (1993-1998) are described. Improvement in sampling, data validity and reliability are documented over the course of the research program, the advantages of patient-level data are highlighted. The usefulness of these byproduct data for estimation of relative resource weights and other policy applications may be an important factor in hospital and health system decisions to invest in clinical costing technology.
Peters, Johanna; Taute, Wolfgang; Bartscher, Kathrin; Döscher, Claas; Höft, Michael; Knöchel, Reinhard; Breitkreutz, Jörg
2017-04-08
Microwave sensor systems using resonance technology at a single resonance in the range of 2-3 GHz have been shown to be a rapid and reliable tool for moisture determination in solid materials including pharmaceutical granules. So far, their application is limited to lower moisture ranges or limitations above certain moisture contents had to be accepted. Aim of the present study was to develop a novel multi-resonance sensor system in order to expand the measurement range. Therefore, a novel sensor using additional resonances over a wide frequency band was designed and used to investigate inherent limitations of first generation sensor systems and material-related limits. Using granule samples with different moisture contents, an experimental protocol for calibration and validation of the method was established. Pursuant to this protocol, a multiple linear regression (MLR) prediction model built by correlating microwave moisture values to the moisture determined by Karl Fischer titration was chosen and rated using conventional criteria such as coefficient of determination (R 2 ) and root mean square error of calibration (RMSEC). Using different operators, different analysis dates and different ambient conditions the method was fully validated following the guidance of ICH Q2(R1). The study clearly showed explanations for measurement uncertainties of first generation sensor systems which confirmed the approach to overcome these by using additional resonances. The established prediction model could be validated in the range of 7.6-19.6%, demonstrating its fit for its future purpose, the moisture content determination during wet granulations. Copyright © 2017 Elsevier B.V. All rights reserved.
Remote sensing validation through SOOP technology: implementation of Spectra system
NASA Astrophysics Data System (ADS)
Piermattei, Viviana; Madonia, Alice; Bonamano, Simone; Consalvi, Natalizia; Caligiore, Aurelio; Falcone, Daniela; Puri, Pio; Sarti, Fabio; Spaccavento, Giovanni; Lucarini, Diego; Pacci, Giacomo; Amitrano, Luigi; Iacullo, Salvatore; D'Andrea, Salvatore; Marcelli, Marco
2017-04-01
The development of low-cost instrumentation plays a key role in marine environmental studies and represents one of the most innovative aspects of marine research. The availability of low-cost technologies allows the realization of extended observatory networks for the study of marine phenomena through an integrated approach merging observations, remote sensing and operational oceanography. Marine services and practical applications critically depends on the availability of large amount of data collected with sufficiently dense spatial and temporal sampling. This issue directly influences the robustness both of ocean forecasting models and remote sensing observations through data assimilation and validation processes, particularly in the biological domain. For this reason it is necessary the development of cheap, small and integrated smart sensors, which could be functional both for satellite data validation and forecasting models data assimilation as well as to support early warning systems for environmental pollution control and prevention. This is particularly true in coastal areas, which are subjected to multiple anthropic pressures. Moreover, coastal waters can be classified like case 2 waters, where the optical properties of inorganic suspended matter and chromophoric dissolved organic matter must be considered and separated by the chlorophyll a contribution. Due to the high costs of mooring systems, research vessels, measure platforms and instrumentation a big effort was dedicated to the design, development and realization of a new low cost mini-FerryBox system: Spectra. Thanks to the modularity and user-friendly employment of the system, Spectra allows to acquire continuous in situ measures of temperature, conductivity, turbidity, chlorophyll a and chromophoric dissolved organic matter (CDOM) fluorescences from voluntary vessels, even by non specialized operators (Marcelli et al., 2014; 2016). This work shows the preliminary application of this technology to remote sensing data validation.
Lin, Yuanjie; Feng, Chao; Xu, Qian; Lu, Dasheng; Qiu, Xinlei; Jin, Yu'e; Wang, Guoquan; Wang, Dongli; She, Jianwen; Zhou, Zhijun
2016-07-01
An improved method based on tandem solid phase extraction (SPE) cleanup and gas chromatography-high resolution mass spectrometry (GC-HRMS) has been validated for a rapid determination of dibenzo-p-dioxins/furans (PCDD/Fs), dioxin-like polychlorinated biphenyls (PCBs), marker polychlorinated biphenyls (M-PCBs), and polybrominated diphenyl ethers (PBDEs) using a large volume (50 mL) of human milk. This method was well validated for the measurement of these analytes in human milk from the general population with low limits of detection (LODs, 0.004-0.12 ng/g lipid), satisfactory accuracy (75-120 % of recoveries), and precision [less than 10 % of relative standard deviations (RSDs)]. To comprehensively evaluate the performance of this method, a good, presently validated and routinely used method based on an automated sample clean-up system (ASCS, based on the commercial acid multilayer silica, basic alumina, and carbon columns) was used in parallel for comparison. Compared with the ASCS method, this method presented comparable specificity. Additionally, this method, in contrast to ASCS method, highly reduced consumption of solvents (40 mL versus 500 mL), which results in much lower background in the procedural blank, reduced time, and enhanced sample pretreatment throughput. This method was also applied in a pilot study to measure a batch of human milk samples with satisfactory results. Graphical Abstract Characteristics of the application of tandem SPE cleanup for determination of PCDD/Fs, DL-PCBs,M-PCBs and PBDEs in human milk.
Basavanhally, Ajay; Viswanath, Satish; Madabhushi, Anant
2015-01-01
Clinical trials increasingly employ medical imaging data in conjunction with supervised classifiers, where the latter require large amounts of training data to accurately model the system. Yet, a classifier selected at the start of the trial based on smaller and more accessible datasets may yield inaccurate and unstable classification performance. In this paper, we aim to address two common concerns in classifier selection for clinical trials: (1) predicting expected classifier performance for large datasets based on error rates calculated from smaller datasets and (2) the selection of appropriate classifiers based on expected performance for larger datasets. We present a framework for comparative evaluation of classifiers using only limited amounts of training data by using random repeated sampling (RRS) in conjunction with a cross-validation sampling strategy. Extrapolated error rates are subsequently validated via comparison with leave-one-out cross-validation performed on a larger dataset. The ability to predict error rates as dataset size increases is demonstrated on both synthetic data as well as three different computational imaging tasks: detecting cancerous image regions in prostate histopathology, differentiating high and low grade cancer in breast histopathology, and detecting cancerous metavoxels in prostate magnetic resonance spectroscopy. For each task, the relationships between 3 distinct classifiers (k-nearest neighbor, naive Bayes, Support Vector Machine) are explored. Further quantitative evaluation in terms of interquartile range (IQR) suggests that our approach consistently yields error rates with lower variability (mean IQRs of 0.0070, 0.0127, and 0.0140) than a traditional RRS approach (mean IQRs of 0.0297, 0.0779, and 0.305) that does not employ cross-validation sampling for all three datasets. PMID:25993029
Silva de Lima, Ana Lígia; Evers, Luc J W; Hahn, Tim; Bataille, Lauren; Hamilton, Jamie L; Little, Max A; Okuma, Yasuyuki; Bloem, Bastiaan R; Faber, Marjan J
2017-08-01
Despite the large number of studies that have investigated the use of wearable sensors to detect gait disturbances such as Freezing of gait (FOG) and falls, there is little consensus regarding appropriate methodologies for how to optimally apply such devices. Here, an overview of the use of wearable systems to assess FOG and falls in Parkinson's disease (PD) and validation performance is presented. A systematic search in the PubMed and Web of Science databases was performed using a group of concept key words. The final search was performed in January 2017, and articles were selected based upon a set of eligibility criteria. In total, 27 articles were selected. Of those, 23 related to FOG and 4 to falls. FOG studies were performed in either laboratory or home settings, with sample sizes ranging from 1 PD up to 48 PD presenting Hoehn and Yahr stage from 2 to 4. The shin was the most common sensor location and accelerometer was the most frequently used sensor type. Validity measures ranged from 73-100% for sensitivity and 67-100% for specificity. Falls and fall risk studies were all home-based, including samples sizes of 1 PD up to 107 PD, mostly using one sensor containing accelerometers, worn at various body locations. Despite the promising validation initiatives reported in these studies, they were all performed in relatively small sample sizes, and there was a significant variability in outcomes measured and results reported. Given these limitations, the validation of sensor-derived assessments of PD features would benefit from more focused research efforts, increased collaboration among researchers, aligning data collection protocols, and sharing data sets.
Absorption in Sport: A Cross-Validation Study
Koehn, Stefan; Stavrou, Nektarios A. M.; Cogley, Jeremy; Morris, Tony; Mosek, Erez; Watt, Anthony P.
2017-01-01
Absorption has been identified as readiness for experiences of deep involvement in the task. Conceptually, absorption is a key psychological construct, incorporating experiential, cognitive, and motivational components. Although, no operationalization of the construct has been provided to facilitate research in this area, the purpose of this research was the development and examination of the psychometric properties of a sport-specific measure of absorption that evolved from the use of the modified Tellegen Absorption Scale (MODTAS; Jamieson, 2005) in mainstream psychology. The study aimed to provide evidence of the psychometric properties, reliability, and validity of the Measure of Absorption in Sport Contexts (MASCs). The psychometric examination included a calibration sample from Scotland and a cross-validation sample from Australia using a cross-sectional design. The item pool was developed based on existing items from the modified Tellegen Absorption Scale (Jamieson, 2005). The MODTAS items were reworded and translated into a sport context. The Scottish sample consisted of 292 participants and the Australian sample of 314 participants. Congeneric model testing and confirmatory factor analysis for both samples and multi-group invariance testing across samples was used. In the cross-validation sample the MASC subscales showed acceptable internal consistency and construct reliability (≥0.70). Excellent fit indices were found for the final 18-item, six-factor measure in the cross-validation sample, χ(120)2 = 197.486, p < 0.001; CFI = 0.957; TLI = 0.945; RMSEA = 0.045; SRMR = 0.044. Multi-group invariance testing revealed no differences in item meaning, except for two items. The MASC and the Dispositional Flow Scale-2 showed moderate-to-strong positive correlations in both samples, r = 0.38, p < 0.001 and r = 0.42, p < 0.001, supporting the external validity of the MASC. This article provides initial evidence in support of the psychometric properties, reliability, and validity of the sport-specific measure of absorption. The MASC provides rich research opportunities in sport psychology that can enhance the theoretical understanding between absorption and related constructs and facilitate future intervention studies. PMID:28883802
2012-01-01
Background No previous studies have addressed the integrated relationships among system quality, service quality, job satisfaction, and system performance; this study attempts to bridge such a gap with evidence-based practice study. Methods The convenience sampling method was applied to the information system users of three hospitals in southern Taiwan. A total of 500 copies of questionnaires were distributed, and 283 returned copies were valid, suggesting a valid response rate of 56.6%. SPSS 17.0 and AMOS 17.0 (structural equation modeling) statistical software packages were used for data analysis and processing. Results The findings are as follows: System quality has a positive influence on service quality (γ11= 0.55), job satisfaction (γ21= 0.32), and system performance (γ31= 0.47). Service quality (β31= 0.38) and job satisfaction (β32= 0.46) will positively influence system performance. Conclusions It is thus recommended that the information office of hospitals and developers take enhancement of service quality and user satisfaction into consideration in addition to placing b on system quality and information quality when designing, developing, or purchasing an information system, in order to improve benefits and gain more achievements generated by hospital information systems. PMID:23171394
Validating Analytical Protocols to Determine Selected Pesticides and PCBs Using Routine Samples.
Pindado Jiménez, Oscar; García Alonso, Susana; Pérez Pastor, Rosa María
2017-01-01
This study aims at providing recommendations concerning the validation of analytical protocols by using routine samples. It is intended to provide a case-study on how to validate the analytical methods in different environmental matrices. In order to analyze the selected compounds (pesticides and polychlorinated biphenyls) in two different environmental matrices, the current work has performed and validated two analytical procedures by GC-MS. A description is given of the validation of the two protocols by the analysis of more than 30 samples of water and sediments collected along nine months. The present work also scopes the uncertainty associated with both analytical protocols. In detail, uncertainty of water sample was performed through a conventional approach. However, for the sediments matrices, the estimation of proportional/constant bias is also included due to its inhomogeneity. Results for the sediment matrix are reliable, showing a range 25-35% of analytical variability associated with intermediate conditions. The analytical methodology for the water matrix determines the selected compounds with acceptable recoveries and the combined uncertainty ranges between 20 and 30%. Analyzing routine samples is rarely applied to assess trueness of novel analytical methods and up to now this methodology was not focused on organochlorine compounds in environmental matrices.
ERIC Educational Resources Information Center
Nelson, Jason M.; Canivez, Gary L.
2012-01-01
Empirical examination of the Reynolds Intellectual Assessment Scales (RIAS; C. R. Reynolds & R. W. Kamphaus, 2003a) has produced mixed results regarding its internal structure and convergent validity. Various aspects of validity of RIAS scores with a sample (N = 521) of adolescents and adults seeking psychological evaluations at a university-based…
Development and Validation of Scores from an Instrument Measuring Student Test-Taking Motivation
ERIC Educational Resources Information Center
Eklof, Hanna
2006-01-01
Using the expectancy-value model of achievement motivation as a basis, this study's purpose is to develop, apply, and validate scores from a self-report instrument measuring student test-taking motivation. Sampled evidence of construct validity for the present sample indicates that a number of the items in the instrument could be used as an…
Validation of the Short Form of the Career Development Inventory with an Iranian High School Sample
ERIC Educational Resources Information Center
Sadeghi, Ahmad; Baghban, Iran; Bahrami, Fatemeh; Ahmadi, Ahmad; Creed, Peter
2011-01-01
A short 33-item form of the Career Development Inventory was validated on a sample of 310 Iranian high school students. Factor analysis indicated that attitude and cognitive subscale items loaded on their respective factors, and that internal reliability coefficients at all levels were satisfactory to good. Support for validity was demonstrated by…
Development of Creative Behavior Observation Form: A Study on Validity and Reliability
ERIC Educational Resources Information Center
Dere, Zeynep; Ömeroglu, Esra
2018-01-01
This study, Creative Behavior Observation Form was developed to assess creativity of the children. While the study group on the reliability and validity of Creative Behavior Observation Form was being developed, 257 children in total who were at the ages of 5-6 were used as samples with stratified sampling method. Content Validity Index (CVI) and…
Burns, G Leonard; Walsh, James A; Servera, Mateu; Lorenzo-Seva, Urbano; Cardo, Esther; Rodríguez-Fornells, Antoni
2013-01-01
Exploratory structural equation modeling (SEM) was applied to a multiple indicator (26 individual symptom ratings) by multitrait (ADHD-IN, ADHD-HI and ODD factors) by multiple source (mothers, fathers and teachers) model to test the invariance, convergent and discriminant validity of the Child and Adolescent Disruptive Behavior Inventory with 872 Thai adolescents and the ADHD Rating Scale-IV and ODD scale of the Disruptive Behavior Inventory with 1,749 Spanish children. Most of the individual ADHD/ODD symptoms showed convergent and discriminant validity with the loadings and thresholds being invariant over mothers, fathers and teachers in both samples (the three latent factor means were higher for parents than teachers). The ADHD-IN, ADHD-HI and ODD latent factors demonstrated convergent and discriminant validity between mothers and fathers within the two samples. Convergent and discriminant validity between parents and teachers for the three factors was either absent (Thai sample) or only partial (Spanish sample). The application of exploratory SEM to a multiple indicator by multitrait by multisource model should prove useful for the evaluation of the construct validity of the forthcoming DSM-V ADHD/ODD rating scales.
A Decision Tree for Nonmetric Sex Assessment from the Skull.
Langley, Natalie R; Dudzik, Beatrix; Cloutier, Alesia
2018-01-01
This study uses five well-documented cranial nonmetric traits (glabella, mastoid process, mental eminence, supraorbital margin, and nuchal crest) and one additional trait (zygomatic extension) to develop a validated decision tree for sex assessment. The decision tree was built and cross-validated on a sample of 293 U.S. White individuals from the William M. Bass Donated Skeletal Collection. Ordinal scores from the six traits were analyzed using the partition modeling option in JMP Pro 12. A holdout sample of 50 skulls was used to test the model. The most accurate decision tree includes three variables: glabella, zygomatic extension, and mastoid process. This decision tree yielded 93.5% accuracy on the training sample, 94% on the cross-validated sample, and 96% on a holdout validation sample. Linear weighted kappa statistics indicate acceptable agreement among observers for these variables. Mental eminence should be avoided, and definitions and figures should be referenced carefully to score nonmetric traits. © 2017 American Academy of Forensic Sciences.
The ties that bind: interorganizational linkages and physician-system alignment.
Alexander, J A; Waters, T M; Burns, L R; Shortell, S M; Gillies, R R; Budetti, P P; Zuckerman, H S
2001-07-01
To examine the association between the degree of alignment between physicians and health care systems, and interorganizational linkages between physician groups and health care systems. The study used a cross sectional, comparative analysis using a sample of 1,279 physicians practicing in loosely affiliated arrangements and 1,781 physicians in 61 groups closely affiliated with 14 vertically integrated health systems. Measures of physician alignment were based on multiitem scales validated in previous studies and derived from surveys sent to individual physicians. Measures of interorganizational linkages were specified at the institutional, administrative, and technical core levels of the physician group and were developed from surveys sent to the administrator of each of the 61 physician groups in the sample. Two stage Heckman models with fixed effects adjustments in the second stage were used to correct for sample selection and clustering respectively. After accounting for sample selection, fixed effects, and group and individual controls, physicians in groups with more valued practice service linkages display consistently higher alignment with systems than physicians in groups that have fewer such linkages. Results also suggest that centralized administrative control lowers physician-system alignment for selected measures of alignment. Governance interlocks exhibited only weak associations with alignment. Our findings suggest that alignment generally follows resource exchanges that promote value-added contributions to physicians and physician groups while preserving control and authority within the group.
Garrido-Delgado, Rocío; Arce, Lourdes; Valcárcel, Miguel
2012-01-01
The potential of a headspace device coupled to multi-capillary column-ion mobility spectrometry has been studied as a screening system to differentiate virgin olive oils ("lampante," "virgin," and "extra virgin" olive oil). The last two types are virgin olive oil samples of very similar characteristics, which were very difficult to distinguish with the existing analytical method. The procedure involves the direct introduction of the virgin olive oil sample into a vial, headspace generation, and automatic injection of the volatiles into a gas chromatograph-ion mobility spectrometer. The data obtained after the analysis by duplicate of 98 samples of three different categories of virgin olive oils, were preprocessed and submitted to a detailed chemometric treatment to classify the virgin olive oil samples according to their sensory quality. The same virgin olive oil samples were also analyzed by an expert's panel to establish their category and use these data as reference values to check the potential of this new screening system. This comparison confirms the potential of the results presented here. The model was able to classify 97% of virgin olive oil samples in their corresponding group. Finally, the chemometric method was validated obtaining a percentage of prediction of 87%. These results provide promising perspectives for the use of ion mobility spectrometry to differentiate virgin olive oil samples according to their quality instead of using the classical analytical procedure.
Olives, Casey; Pagano, Marcello; Deitchler, Megan; Hedt, Bethany L; Egge, Kari; Valadez, Joseph J
2009-01-01
Traditional lot quality assurance sampling (LQAS) methods require simple random sampling to guarantee valid results. However, cluster sampling has been proposed to reduce the number of random starting points. This study uses simulations to examine the classification error of two such designs, a 67×3 (67 clusters of three observations) and a 33×6 (33 clusters of six observations) sampling scheme to assess the prevalence of global acute malnutrition (GAM). Further, we explore the use of a 67×3 sequential sampling scheme for LQAS classification of GAM prevalence. Results indicate that, for independent clusters with moderate intracluster correlation for the GAM outcome, the three sampling designs maintain approximate validity for LQAS analysis. Sequential sampling can substantially reduce the average sample size that is required for data collection. The presence of intercluster correlation can impact dramatically the classification error that is associated with LQAS analysis. PMID:20011037
Validity and reliability of the Paprosky acetabular defect classification.
Yu, Raymond; Hofstaetter, Jochen G; Sullivan, Thomas; Costi, Kerry; Howie, Donald W; Solomon, Lucian B
2013-07-01
The Paprosky acetabular defect classification is widely used but has not been appropriately validated. Reliability of the Paprosky system has not been evaluated in combination with standardized techniques of measurement and scoring. This study evaluated the reliability, teachability, and validity of the Paprosky acetabular defect classification. Preoperative radiographs from a random sample of 83 patients undergoing 85 acetabular revisions were classified by four observers, and their classifications were compared with quantitative intraoperative measurements. Teachability of the classification scheme was tested by dividing the four observers into two groups. The observers in Group 1 underwent three teaching sessions; those in Group 2 underwent one session and the influence of teaching on the accuracy of their classifications was ascertained. Radiographic evaluation showed statistically significant relationships with intraoperative measurements of anterior, medial, and superior acetabular defect sizes. Interobserver reliability improved substantially after teaching and did not improve without it. The weighted kappa coefficient went from 0.56 at Occasion 1 to 0.79 after three teaching sessions in Group 1 observers, and from 0.49 to 0.65 after one teaching session in Group 2 observers. The Paprosky system is valid and shows good reliability when combined with standardized definitions of radiographic landmarks and a structured analysis. Level II, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.
Salsman, John M; Victorson, David; Choi, Seung W; Peterman, Amy H; Heinemann, Allen W; Nowinski, Cindy; Cella, David
2013-11-01
To develop and validate an item-response theory-based patient-reported outcomes assessment tool of positive affect and well-being (PAW). This is part of a larger NINDS-funded study to develop a health-related quality of life measurement system across major neurological disorders, called Neuro-QOL. Informed by a literature review and qualitative input from clinicians and patients, item pools were created to assess PAW concepts. Items were administered to a general population sample (N = 513) and a group of individuals with a variety of neurologic conditions (N = 581) for calibration and validation purposes, respectively. A 23-item calibrated bank and a 9-item short form of PAW was developed, reflecting components of positive affect, life satisfaction, or an overall sense of purpose and meaning. The Neuro-QOL PAW measure demonstrated sufficient unidimensionality and displayed good internal consistency, test-retest reliability, model fit, convergent and discriminant validity, and responsiveness. The Neuro-QOL PAW measure was designed to aid clinicians and researchers to better evaluate and understand the potential role of positive health processes for individuals with chronic neurological conditions. Further psychometric testing within and between neurological conditions, as well as testing in non-neurologic chronic diseases, will help evaluate the generalizability of this new tool.
García-Molina, María Dolores; García-Olmo, Juan; Barro, Francisco
2016-01-01
The aim of this work was to assess the ability of Near Infrared Spectroscopy (NIRS) to distinguish wheat lines with low gliadin content, obtained by RNA interference (RNAi), from non-transgenic wheat lines. The discriminant analysis was performed using both whole grain and flour. The transgenic sample set included 409 samples for whole grain sorting and 414 samples for flour experiments, while the non-transgenic set consisted of 126 and 156 samples for whole grain and flour, respectively. Samples were scanned using a Foss-NIR Systems 6500 System II instrument. Discrimination models were developed using the entire spectral range (400-2500 nm) and ranges of 400-780 nm, 800-1098 nm and 1100-2500 nm, followed by analysis of means of partial least square (PLS). Two external validations were made, using samples from the years 2013 and 2014 and a minimum of 99% of the flour samples and 96% of the whole grain samples were classified correctly. The results demonstrate the ability of NIRS to successfully discriminate between wheat samples with low-gliadin content and wild types. These findings are important for the development and analysis of foodstuff for celiac disease (CD) patients to achieve better dietary composition and a reduction in disease incidence.
[Social self-positioning as indicator of socioeconomic status].
Fernández, E; Alonso, R M; Quer, A; Borrell, C; Benach, J; Alonso, J; Gómez, G
2000-01-01
Self-perceived class results from directly questioning subjects about his or her social class. The aim of this investigation was to analyse self-perceived class in relation to other indicator variables of socioeconomic level. Data from the 1994 Catalan Health Interview Survey, a cross-sectional survey of a representative sample of the non-institutionalised population of Catalonia was used. We conducted a discriminant analysis to compute the degree of right classification when different socioeconomic variables potentially related to self-perceived class were considered. All subjects who directly answered the questionnaire were included (N = 12,245). With the aim of obtaining the discriminant functions in a group of subjects and to validate it in another one, the subjects were divided into two random samples, containing approximately 75% and 25% of subjects (analysis sample, n = 9,248; and validation sample, n = 2,997). The final function for men and women included level of education, social class (based in occupation) and equivalent income. This function correctly classified 40.9% of the subjects in the analysis sample and 39.2% in the validation sample. Two other functions were selected for men and women separately. In men, the function included level of education, professional category, and family income (39.2% of classification in analysis sample and 37.2% in validation sample). In women, the function (level of education, working status, and equivalent income) correctly classified 40.3% of women in analysis sample whereas the percentage was 38.9% in validation sample. The percentages of right classification were higher for the highest and lowest classes. These results show the utility of a simple variable to self-position within the social scale. Self-perceived class is related to education, income, and working determinants.
NASA Astrophysics Data System (ADS)
Lu, Zenghai; Kasaragod, Deepa K.; Matcher, Stephen J.
2011-07-01
We present a phase fluctuation calibration method for polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) using continuous polarization modulation. The method uses a low-voltage broadband polarization modulator driven by a synchronized sinusoidal burst waveform rather than an asynchronous waveform, together with the removal of the global phases of the measured Jones matrices by the use of matrix normalization. This makes it possible to average the measured Jones matrices to remove the artifact due to the speckle noise of the signal in the sample without introducing auxiliary optical components into the sample arm. This method was validated on measurements of an equine tendon sample by the PS-SS-OCT system.
45 CFR 153.350 - Risk adjustment data validation standards.
Code of Federal Regulations, 2012 CFR
2012-10-01
... implementation of any risk adjustment software and ensure proper validation of a statistically valid sample of... respect to implementation of risk adjustment software or as a result of data validation conducted pursuant... implementation of risk adjustment software or data validation. ...
2011-01-01
Background Since its inception, proteomics has essentially operated in a discovery mode with the goal of identifying and quantifying the maximal number of proteins in a sample. Increasingly, proteomic measurements are also supporting hypothesis-driven studies, in which a predetermined set of proteins is consistently detected and quantified in multiple samples. Selected reaction monitoring (SRM) is a targeted mass spectrometric technique that supports the detection and quantification of specific proteins in complex samples at high sensitivity and reproducibility. Here, we describe ATAQS, an integrated software platform that supports all stages of targeted, SRM-based proteomics experiments including target selection, transition optimization and post acquisition data analysis. This software will significantly facilitate the use of targeted proteomic techniques and contribute to the generation of highly sensitive, reproducible and complete datasets that are particularly critical for the discovery and validation of targets in hypothesis-driven studies in systems biology. Result We introduce a new open source software pipeline, ATAQS (Automated and Targeted Analysis with Quantitative SRM), which consists of a number of modules that collectively support the SRM assay development workflow for targeted proteomic experiments (project management and generation of protein, peptide and transitions and the validation of peptide detection by SRM). ATAQS provides a flexible pipeline for end-users by allowing the workflow to start or end at any point of the pipeline, and for computational biologists, by enabling the easy extension of java algorithm classes for their own algorithm plug-in or connection via an external web site. This integrated system supports all steps in a SRM-based experiment and provides a user-friendly GUI that can be run by any operating system that allows the installation of the Mozilla Firefox web browser. Conclusions Targeted proteomics via SRM is a powerful new technique that enables the reproducible and accurate identification and quantification of sets of proteins of interest. ATAQS is the first open-source software that supports all steps of the targeted proteomics workflow. ATAQS also provides software API (Application Program Interface) documentation that enables the addition of new algorithms to each of the workflow steps. The software, installation guide and sample dataset can be found in http://tools.proteomecenter.org/ATAQS/ATAQS.html PMID:21414234
Manterola, Carlos; Torres, Rodrigo; Burgos, Luis; Vial, Manuel; Pineda, Viviana
2006-07-01
Surgery is a curative treatment for gastric cancer (GC). As relapse is frequent, adjuvant therapies such as postoperative chemo radiotherapy have been tried. In Chile, some hospitals adopted Macdonald's study as a protocol for the treatment of GC. To determine methodological quality and internal and external validity of the Macdonald study. Three instruments were applied that assess methodological quality. A critical appraisal was done and the internal and external validity of the methodological quality was analyzed with two scales: MINCIR (Methodology and Research in Surgery), valid for therapy studies and CONSORT (Consolidated Standards of Reporting Trials), valid for randomized controlled trials (RCT). Guides and scales were applied by 5 researchers with training in clinical epidemiology. The reader's guide verified that the Macdonald study was not directed to answer a clearly defined question. There was random assignment, but the method used is not described and the patients were not considered until the end of the study (36% of the group with surgery plus chemo radiotherapy did not complete treatment). MINCIR scale confirmed a multicentric RCT, not blinded, with an unclear randomized sequence, erroneous sample size estimation, vague objectives and no exclusion criteria. CONSORT system proved the lack of working hypothesis and specific objectives as well as an absence of exclusion criteria and identification of the primary variable, an imprecise estimation of sample size, ambiguities in the randomization process, no blinding, an absence of statistical adjustment and the omission of a subgroup analysis. The instruments applied demonstrated methodological shortcomings that compromise the internal and external validity of the.
Leveraging biospecimen resources for discovery or validation of markers for early cancer detection.
Schully, Sheri D; Carrick, Danielle M; Mechanic, Leah E; Srivastava, Sudhir; Anderson, Garnet L; Baron, John A; Berg, Christine D; Cullen, Jennifer; Diamandis, Eleftherios P; Doria-Rose, V Paul; Goddard, Katrina A B; Hankinson, Susan E; Kushi, Lawrence H; Larson, Eric B; McShane, Lisa M; Schilsky, Richard L; Shak, Steven; Skates, Steven J; Urban, Nicole; Kramer, Barnett S; Khoury, Muin J; Ransohoff, David F
2015-04-01
Validation of early detection cancer biomarkers has proven to be disappointing when initial promising claims have often not been reproducible in diagnostic samples or did not extend to prediagnostic samples. The previously reported lack of rigorous internal validity (systematic differences between compared groups) and external validity (lack of generalizability beyond compared groups) may be effectively addressed by utilizing blood specimens and data collected within well-conducted cohort studies. Cohort studies with prediagnostic specimens (eg, blood specimens collected prior to development of clinical symptoms) and clinical data have recently been used to assess the validity of some early detection biomarkers. With this background, the Division of Cancer Control and Population Sciences (DCCPS) and the Division of Cancer Prevention (DCP) of the National Cancer Institute (NCI) held a joint workshop in August 2013. The goal was to advance early detection cancer research by considering how the infrastructure of cohort studies that already exist or are being developed might be leveraged to include appropriate blood specimens, including prediagnostic specimens, ideally collected at periodic intervals, along with clinical data about symptom status and cancer diagnosis. Three overarching recommendations emerged from the discussions: 1) facilitate sharing of existing specimens and data, 2) encourage collaboration among scientists developing biomarkers and those conducting observational cohort studies or managing healthcare systems with cohorts followed over time, and 3) conduct pilot projects that identify and address key logistic and feasibility issues regarding how appropriate specimens and clinical data might be collected at reasonable effort and cost within existing or future cohorts. © Published by Oxford University Press 2015.
Leveraging Biospecimen Resources for Discovery or Validation of Markers for Early Cancer Detection
Carrick, Danielle M.; Mechanic, Leah E.; Srivastava, Sudhir; Anderson, Garnet L.; Baron, John A.; Berg, Christine D.; Cullen, Jennifer; Diamandis, Eleftherios P.; Doria-Rose, V. Paul; Goddard, Katrina A. B.; Hankinson, Susan E.; Kushi, Lawrence H.; Larson, Eric B.; McShane, Lisa M.; Schilsky, Richard L.; Shak, Steven; Skates, Steven J.; Urban, Nicole; Kramer, Barnett S.; Khoury, Muin J.; Ransohoff, David F.
2015-01-01
Validation of early detection cancer biomarkers has proven to be disappointing when initial promising claims have often not been reproducible in diagnostic samples or did not extend to prediagnostic samples. The previously reported lack of rigorous internal validity (systematic differences between compared groups) and external validity (lack of generalizability beyond compared groups) may be effectively addressed by utilizing blood specimens and data collected within well-conducted cohort studies. Cohort studies with prediagnostic specimens (eg, blood specimens collected prior to development of clinical symptoms) and clinical data have recently been used to assess the validity of some early detection biomarkers. With this background, the Division of Cancer Control and Population Sciences (DCCPS) and the Division of Cancer Prevention (DCP) of the National Cancer Institute (NCI) held a joint workshop in August 2013. The goal was to advance early detection cancer research by considering how the infrastructure of cohort studies that already exist or are being developed might be leveraged to include appropriate blood specimens, including prediagnostic specimens, ideally collected at periodic intervals, along with clinical data about symptom status and cancer diagnosis. Three overarching recommendations emerged from the discussions: 1) facilitate sharing of existing specimens and data, 2) encourage collaboration among scientists developing biomarkers and those conducting observational cohort studies or managing healthcare systems with cohorts followed over time, and 3) conduct pilot projects that identify and address key logistic and feasibility issues regarding how appropriate specimens and clinical data might be collected at reasonable effort and cost within existing or future cohorts. PMID:25688116
Milestone-compatible neurology resident assessments: A role for observable practice activities.
Jones, Lyell K; Dimberg, Elliot L; Boes, Christopher J; Eggers, Scott D Z; Dodick, David W; Cutsforth-Gregory, Jeremy K; Leep Hunderfund, Andrea N; Capobianco, David J
2015-06-02
Beginning in 2014, US neurology residency programs were required to report each trainee's educational progression within 29 neurology Milestone competency domains. Trainee assessment systems will need to be adapted to inform these requirements. The primary aims of this study were to validate neurology resident assessment content using observable practice activities (OPAs) and to develop assessment formats easily translated to the Neurology Milestones. A modified Delphi technique was used to establish consensus perceptions of importance of 73 neurology OPAs among neurology educators and trainees at 3 neurology residency programs. A content validity score (CVS) was derived for each neurology OPA, with scores ≥4.0 determined in advance to indicate sufficient content validity. The mean CVS for all OPAs was 4.4 (range 3.5-5.0). Fifty-seven (78%) OPAs had a CVS ≥4.0, leaving 16 (22%) below the pre-established threshold for content validity. Trainees assigned a higher importance to individual OPAs (mean CVS 4.6) compared to faculty (mean 4.4, p = 0.016), but the effect size was small (η(2) = 0.10). There was no demonstrated effect of length of education experience on perceived importance of neurology OPAs (p = 0.23). Two sample resident assessment formats were developed, one using neurology OPAs alone and another using a combination of neurology OPAs and the Neurology Milestones. This study provides neurology training programs with content validity evidence for items to include in resident assessments, and sample assessment formats that directly translate to the Neurology Milestones. Length of education experience has little effect on perceptions of neurology OPA importance. © 2015 American Academy of Neurology.
Validation of the Family Inpatient Communication Survey.
Torke, Alexia M; Monahan, Patrick; Callahan, Christopher M; Helft, Paul R; Sachs, Greg A; Wocial, Lucia D; Slaven, James E; Montz, Kianna; Inger, Lev; Burke, Emily S
2017-01-01
Although many family members who make surrogate decisions report problems with communication, there is no validated instrument to accurately measure surrogate/clinician communication for older adults in the acute hospital setting. The objective of this study was to validate a survey of surrogate-rated communication quality in the hospital that would be useful to clinicians, researchers, and health systems. After expert review and cognitive interviewing (n = 10 surrogates), we enrolled 350 surrogates (250 development sample and 100 validation sample) of hospitalized adults aged 65 years and older from three hospitals in one metropolitan area. The communication survey and a measure of decision quality were administered within hospital days 3 and 10. Mental health and satisfaction measures were administered six to eight weeks later. Factor analysis showed support for both one-factor (Total Communication) and two-factor models (Information and Emotional Support). Item reduction led to a final 30-item scale. For the validation sample, internal reliability (Cronbach's alpha) was 0.96 (total), 0.94 (Information), and 0.90 (Emotional Support). Confirmatory factor analysis fit statistics were adequate (one-factor model, comparative fit index = 0.981, root mean square error of approximation = 0.62, weighted root mean square residual = 1.011; two-factor model comparative fit index = 0.984, root mean square error of approximation = 0.055, weighted root mean square residual = 0.930). Total score and subscales showed significant associations with the Decision Conflict Scale (Pearson correlation -0.43, P < 0.001 for total score). Emotional Support was associated with improved mental health outcomes at six to eight weeks, such as anxiety (-0.19 P < 0.001), and Information was associated with satisfaction with the hospital stay (0.49, P < 0.001). The survey shows high reliability and validity in measuring communication experiences for hospital surrogates. The scale has promise for measurement of communication quality and is predictive of important outcomes, such as surrogate satisfaction and well-being. Copyright © 2016 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.
Li, Xianfeng; Murthy, Sanjeeva; Latour, Robert A.
2011-01-01
A new empirical sampling method termed “temperature intervals with global exchange of replicas and reduced radii” (TIGER3) is presented and demonstrated to efficiently equilibrate entangled long-chain molecular systems such as amorphous polymers. The TIGER3 algorithm is a replica exchange method in which simulations are run in parallel over a range of temperature levels at and above a designated baseline temperature. The replicas sampled at temperature levels above the baseline are run through a series of cycles with each cycle containing four stages – heating, sampling, quenching, and temperature level reassignment. The method allows chain segments to pass through one another at elevated temperature levels during the sampling stage by reducing the van der Waals radii of the atoms, thus eliminating chain entanglement problems. Atomic radii are then returned to their regular values and re-equilibrated at elevated temperature prior to quenching to the baseline temperature. Following quenching, replicas are compared using a Metropolis Monte Carlo exchange process for the construction of an approximate Boltzmann-weighted ensemble of states and then reassigned to the elevated temperature levels for additional sampling. Further system equilibration is performed by periodic implementation of the previously developed TIGER2 algorithm between cycles of TIGER3, which applies thermal cycling without radii reduction. When coupled with a coarse-grained modeling approach, the combined TIGER2/TIGER3 algorithm yields fast equilibration of bulk-phase models of amorphous polymer, even for polymers with complex, highly branched structures. The developed method was tested by modeling the polyethylene melt. The calculated properties of chain conformation and chain segment packing agreed well with published data. The method was also applied to generate equilibrated structural models of three increasingly complex amorphous polymer systems: poly(methyl methacrylate), poly(butyl methacrylate), and DTB-succinate copolymer. Calculated glass transition temperature (Tg) and structural parameter profile (S(q)) for each resulting polymer model were found to be in close agreement with experimental Tg values and structural measurements obtained by x-ray diffraction, thus validating that the developed methods provide realistic models of amorphous polymer structure. PMID:21769156
Overview of the Spinal Cord Injury – Quality of Life (SCI-QOL) measurement system
Tulsky, David S.; Kisala, Pamela A.; Victorson, David; Tate, Denise G.; Heinemann, Allen W.; Charlifue, Susan; Kirshblum, Steve C.; Fyffe, Denise; Gershon, Richard; Spungen, Ann M.; Bombardier, Charles H.; Dyson-Hudson, Trevor A.; Amtmann, Dagmar; Z. Kalpakjian, Claire; W. Choi, Seung; Jette, Alan M.; Forchheimer, Martin; Cella, David
2015-01-01
Context/Objective The Spinal Cord Injury – Quality of Life (SCI-QOL) measurement system was developed to address the shortage of relevant and psychometrically sound patient reported outcome (PRO) measures available for clinical care and research in spinal cord injury (SCI) rehabilitation. Using a computer adaptive testing (CAT) approach, the SCI-QOL builds on the Patient Reported Outcomes Measurement Information System (PROMIS) and the Quality of Life in Neurological Disorders (Neuro-QOL) initiative. This initial manuscript introduces the background and development of the SCI-QOL measurement system. Greater detail is presented in the additional manuscripts of this special issue. Design Classical and contemporary test development methodologies were employed. Qualitative input was obtained from individuals with SCI and clinicians through interviews, focus groups, and cognitive debriefing. Item pools were field tested in a multi-site sample (n = 877) and calibrated using item response theory methods. Initial reliability and validity testing was performed in a new sample of individuals with traumatic SCI (n = 245). Setting Five Model SCI System centers and one Department of Veterans Affairs Medical Center across the United States. Participants Adults with traumatic SCI. Interventions n/a Outcome Measures n/a Results The SCI-QOL consists of 19 item banks, including the SCI-Functional Index banks, and 3 fixed-length scales measuring physical, emotional, and social aspects of health-related QOL (HRQOL). Conclusion The SCI-QOL measurement system consists of psychometrically sound measures for individuals with SCI. The manuscripts in this special issue provide evidence of the reliability and initial validity of this measurement system. The SCI-QOL also links to other measures designed for a general medical population. PMID:26010962
A Synopsis of Technical Issues of Concern for Monitoring Trace Elements in Highway and Urban Runoff
Breault, Robert F.; Granato, Gregory E.
2000-01-01
Trace elements, which are regulated for aquatic life protection, are a primary concern in highway- and urban-runoff studies because stormwater runoff may transport these constituents from the land surface to receiving waters. Many of these trace elements are essential for biological activity and become detrimental only when geologic or anthropogenic sources exceed concentrations beyond ranges typical of the natural environment. The Federal Highway Administration and State Transportation Agencies are concerned about the potential effects of highway runoff on the watershed scale and for the management and protection of watersheds. Transportation agencies need information that is documented as valid, current, and scientifically defensible to support planning and management decisions. There are many technical issues of concern for monitoring trace elements; therefore, trace-element data commonly are considered suspect, and the responsibility to provide data-quality information to support the validity of reported results rests with the data-collection agency. Paved surfaces are fundamentally different physically, hydraulically, and chemically from the natural surfaces typical of most freshwater systems that have been the focus of many traceelement- monitoring studies. Existing scientific conceptions of the behavior of trace elements in the environment are based largely upon research on natural systems, rather than on systems typical of pavement runoff. Additionally, the logistics of stormwater sampling are difficult because of the great uncertainty in the occurrence and magnitude of storm events. Therefore, trace-element monitoring programs may be enhanced if monitoring and sampling programs are automated. Automation would standardize the process and provide a continuous record of the variations in flow and water-quality characteristics. Great care is required to collect and process samples in a manner that will minimize potential contamination or attenuation of trace elements and other sources of bias and variability in the sampling process. Trace elements have both natural and anthropogenic sources that may affect the sampling process, including the sample-collection and handling materials used in many trace-element monitoring studies. Trace elements also react with these materials within the timescales typical for collection, processing and analysis of runoff samples. To study the characteristics and potential effects of trace elements in highway and urban runoff, investigators typically sample one or more operationally defined matrixes including: whole water, dissolved (filtered water), suspended sediment, bottom sediment, biological tissue, and contaminant sources. The sampling and analysis of each of these sample matrixes can provide specific information about the occurrence and distribution of trace elements in runoff and receiving waters. There are, however, technical concerns specific to each matrix that must be understood and addressed through use of proper collection and processing protocols. Valid protocols are designed to minimize inherent problems and to maximize the accuracy, precision, comparability, and representativeness of data collected. Documentation, including information about monitoring protocols, quality assurance and quality control efforts, and ancillary data also is necessary to establish data quality. This documentation is especially important for evaluation of historical traceelement monitoring data, because trace-element monitoring protocols and analysis methods have been constantly changing over the past 30 years.
In-flight edge response measurements for high-spatial-resolution remote sensing systems
NASA Astrophysics Data System (ADS)
Blonski, Slawomir; Pagnutti, Mary A.; Ryan, Robert; Zanoni, Vickie
2002-09-01
In-flight measurements of spatial resolution were conducted as part of the NASA Scientific Data Purchase Verification and Validation process. Characterization included remote sensing image products with ground sample distance of 1 meter or less, such as those acquired with the panchromatic imager onboard the IKONOS satellite and the airborne ADAR System 5500 multispectral instrument. Final image products were used to evaluate the effects of both the image acquisition system and image post-processing. Spatial resolution was characterized by full width at half maximum of an edge-response-derived line spread function. The edge responses were analyzed using the tilted-edge technique that overcomes the spatial sampling limitations of the digital imaging systems. As an enhancement to existing algorithms, the slope of the edge response and the orientation of the edge target were determined by a single computational process. Adjacent black and white square panels, either painted on a flat surface or deployed as tarps, formed the ground-based edge targets used in the tests. Orientation of the deployable tarps was optimized beforehand, based on simulations of the imaging system. The effects of such factors as acquisition geometry, temporal variability, Modulation Transfer Function compensation, and ground sample distance on spatial resolution were investigated.
Vuorenmaa, M; Halme, N; Åstedt-Kurki, P; Kaunonen, M; Perälä, M-L
2014-07-01
The Family Empowerment Scale (FES) is a widely used instrument which measures the parents' own sense of their empowerment at the level of the family, service system and community. It was originally developed for parents of children with emotional disabilities. The aims of this study were to evaluate the validity and reliability of the Finnish FES and to examine its responsiveness in measuring the empowerment of parents with small children. The English FES was translated into Finnish using back translation and modified so as to be generic and convenient for all families. The construct, convergent, discriminant and concurrent validities, reliability and responsiveness of the Finnish FES were examined. Participants (n = 955) were the parents of children aged 0-9 years who had been selected using stratified random sampling. Confirmatory factor analysis proved that the Finnish FES had three subscales based on the original FES. Convergent and discriminant validities confirmed and supported the same construct. The relationship between parents' participation and empowerment was tested for concurrent validity. As in previous FES studies, the participating parents were more empowered, which supported the concurrent validity. The reliability of the Finnish FES proved acceptable for both parents. The Finnish FES could also discriminate the responses of the parents. Participation in the activities organized by the family service system influenced parents' perceptions of empowerment more than did their background characteristics. The Finnish FES is a valid and reliable instrument and it is suitable for measuring the empowerment of parents. However, it is necessary to consider how the FES would identify in the best way the parents who perhaps need some help. © 2013 John Wiley & Sons Ltd.
[Development of an analyzing system for soil parameters based on NIR spectroscopy].
Zheng, Li-Hua; Li, Min-Zan; Sun, Hong
2009-10-01
A rapid estimation system for soil parameters based on spectral analysis was developed by using object-oriented (OO) technology. A class of SOIL was designed. The instance of the SOIL class is the object of the soil samples with the particular type, specific physical properties and spectral characteristics. Through extracting the effective information from the modeling spectral data of soil object, a map model was established between the soil parameters and its spectral data, while it was possible to save the mapping model parameters in the database of the model. When forecasting the content of any soil parameter, the corresponding prediction model of this parameter can be selected with the same soil type and the similar soil physical properties of objects. And after the object of target soil samples was carried into the prediction model and processed by the system, the accurate forecasting content of the target soil samples could be obtained. The system includes modules such as file operations, spectra pretreatment, sample analysis, calibrating and validating, and samples content forecasting. The system was designed to run out of equipment. The parameters and spectral data files (*.xls) of the known soil samples can be input into the system. Due to various data pretreatment being selected according to the concrete conditions, the results of predicting content will appear in the terminal and the forecasting model can be stored in the model database. The system reads the predicting models and their parameters are saved in the model database from the module interface, and then the data of the tested samples are transferred into the selected model. Finally the content of soil parameters can be predicted by the developed system. The system was programmed with Visual C++6.0 and Matlab 7.0. And the Access XP was used to create and manage the model database.
A VLF-based technique in applications to digital control of nonlinear hybrid multirate systems
NASA Astrophysics Data System (ADS)
Vassilyev, Stanislav; Ulyanov, Sergey; Maksimkin, Nikolay
2017-01-01
In this paper, a technique for rigorous analysis and design of nonlinear multirate digital control systems on the basis of the reduction method and sublinear vector Lyapunov functions is proposed. The control system model under consideration incorporates continuous-time dynamics of the plant and discrete-time dynamics of the controller and takes into account uncertainties of the plant, bounded disturbances, nonlinear characteristics of sensors and actuators. We consider a class of multirate systems where the control update rate is slower than the measurement sampling rates and periodic non-uniform sampling is admitted. The proposed technique does not use the preliminary discretization of the system, and, hence, allows one to eliminate the errors associated with the discretization and improve the accuracy of analysis. The technique is applied to synthesis of digital controller for a flexible spacecraft in the fine stabilization mode and decentralized controller for a formation of autonomous underwater vehicles. Simulation results are provided to validate the good performance of the designed controllers.
Tey, Wei Keat; Kuang, Ye Chow; Ooi, Melanie Po-Leen; Khoo, Joon Joon
2018-03-01
Interstitial fibrosis in renal biopsy samples is a scarring tissue structure that may be visually quantified by pathologists as an indicator to the presence and extent of chronic kidney disease. The standard method of quantification by visual evaluation presents reproducibility issues in the diagnoses. This study proposes an automated quantification system for measuring the amount of interstitial fibrosis in renal biopsy images as a consistent basis of comparison among pathologists. The system extracts and segments the renal tissue structures based on colour information and structural assumptions of the tissue structures. The regions in the biopsy representing the interstitial fibrosis are deduced through the elimination of non-interstitial fibrosis structures from the biopsy area and quantified as a percentage of the total area of the biopsy sample. A ground truth image dataset has been manually prepared by consulting an experienced pathologist for the validation of the segmentation algorithms. The results from experiments involving experienced pathologists have demonstrated a good correlation in quantification result between the automated system and the pathologists' visual evaluation. Experiments investigating the variability in pathologists also proved the automated quantification error rate to be on par with the average intra-observer variability in pathologists' quantification. Interstitial fibrosis in renal biopsy samples is a scarring tissue structure that may be visually quantified by pathologists as an indicator to the presence and extent of chronic kidney disease. The standard method of quantification by visual evaluation presents reproducibility issues in the diagnoses due to the uncertainties in human judgement. An automated quantification system for accurately measuring the amount of interstitial fibrosis in renal biopsy images is presented as a consistent basis of comparison among pathologists. The system identifies the renal tissue structures through knowledge-based rules employing colour space transformations and structural features extraction from the images. In particular, the renal glomerulus identification is based on a multiscale textural feature analysis and a support vector machine. The regions in the biopsy representing interstitial fibrosis are deduced through the elimination of non-interstitial fibrosis structures from the biopsy area. The experiments conducted evaluate the system in terms of quantification accuracy, intra- and inter-observer variability in visual quantification by pathologists, and the effect introduced by the automated quantification system on the pathologists' diagnosis. A 40-image ground truth dataset has been manually prepared by consulting an experienced pathologist for the validation of the segmentation algorithms. The results from experiments involving experienced pathologists have demonstrated an average error of 9 percentage points in quantification result between the automated system and the pathologists' visual evaluation. Experiments investigating the variability in pathologists involving samples from 70 kidney patients also proved the automated quantification error rate to be on par with the average intra-observer variability in pathologists' quantification. The accuracy of the proposed quantification system has been validated with the ground truth dataset and compared against the pathologists' quantification results. It has been shown that the correlation between different pathologists' estimation of interstitial fibrosis area has significantly improved, demonstrating the effectiveness of the quantification system as a diagnostic aide. Copyright © 2017 Elsevier B.V. All rights reserved.
Psychometric evaluation of the Revised Professional Practice Environment (RPPE) scale.
Erickson, Jeanette Ives; Duffy, Mary E; Ditomassi, Marianne; Jones, Dorothy
2009-05-01
The purpose was to examine the psychometric properties of the Revised Professional Practice Environment (RPPE) scale. Despite renewed focus on studying health professionals' practice environments, there are still few reliable and valid instruments available to assist nurse administrators in decision making. A psychometric evaluation using a random-sample cross-validation procedure (calibration sample [CS], n = 775; validation sample [VS], n = 775) was undertaken. Cronbach alpha internal consistency reliability of the total score (r = 0.93 [CS] and 0.92 [VS]), resulting subscale scores (r range: 0.80-0.87 [CS], 0.81-0.88 [VS]), and principal components analyses with Varimax rotation and Kaiser normalization (8 components, 59.2% variance [CS], 59.7% [VS]) produced almost identical results in both samples. The multidimensional RPPE is a psychometrically sound measure of 8 components of the professional practice environment in the acute care setting and sufficiently reliable and valid for use as independent subscales in healthcare research.
Orthorexia nervosa: validation of a diagnosis questionnaire.
Donini, L M; Marsili, D; Graziani, M P; Imbriale, M; Cannella, C
2005-06-01
To validate a questionnaire for the diagnosis of orhorexia oervosa, an eating disorder defined as "maniacal obsession for healthy food". 525 subjects were enrolled. Then they were randomized into two samples (sample of 404 subjects for the construction of the test for the diagnosis of orthorexia ORTO-15; sample of 121 subjects for the validation of the test). The ORTO-15 questionnaire, validated for the diagnosis of orthorexia, is made-up of 15 multiple-choice items. The test we proposed for the diagnosis of orthorexia (ORTO 15) showed a good predictive capability at a threshold value of 40 (efficacy 73.8%, sensitivity 55.6% and specificity 75.8%) also on verification with a control sample. However, it has a limit in identifying the obsessive disorder. For this reason we maintain that further investigation is necessary and that new questions useful for the evaluation of the obsessive-compulsive behavior should be added to the ORTO-15 questionnaire.
Quantitative bioanalysis of strontium in human serum by inductively coupled plasma-mass spectrometry
Somarouthu, Srikanth; Ohh, Jayoung; Shaked, Jonathan; Cunico, Robert L; Yakatan, Gerald; Corritori, Suzana; Tami, Joe; Foehr, Erik D
2015-01-01
Aim: A bioanalytical method using inductively-coupled plasma-mass spectrometry to measure endogenous levels of strontium in human serum was developed and validated. Results & methodology: This article details the experimental procedures used for the method development and validation thus demonstrating the application of the inductively-coupled plasma-mass spectrometry method for quantification of strontium in human serum samples. The assay was validated for specificity, linearity, accuracy, precision, recovery and stability. Significant endogenous levels of strontium are present in human serum samples ranging from 19 to 96 ng/ml with a mean of 34.6 ± 15.2 ng/ml (SD). Discussion & conclusion: Calibration procedures and sample pretreatment were simplified for high throughput analysis. The validation demonstrates that the method was sensitive, selective for quantification of strontium (88Sr) and is suitable for routine clinical testing of strontium in human serum samples. PMID:28031925
A Novel Technique for Sterilization Using a Power Self-Regulated Single-Mode Microwave Cavity.
Reverte-Ors, Juan D; Pedreño-Molina, Juan L; Fernández, Pablo S; Lozano-Guerrero, Antonio J; Periago, Paula M; Díaz-Morcillo, Alejandro
2017-06-07
In this paper, a novel technique to achieve precise temperatures in food sterilization has been proposed. An accurate temperature profile is needed in order to reach a commitment between the total removal of pathogens inside the product and the preservation of nutritional and organoleptic characteristics. The minimal variation of the target temperature in the sample by means of a monitoring and control software platform, allowing temperature stabilization over 100 °C, is the main goal of this work. A cylindrical microwave oven, under pressure conditions and continuous control of the microwave supply power as function of the final temperature inside the sample, has been designed and developed with conditions of single-mode resonance. The uniform heating in the product is achieved by means of sample movement and the self-regulated power control using the measured temperature. Finally, for testing the sterilization of food with this technology, specific biological validation based on Bacillus cereus as a biosensor of heat inactivation has been incorporated as a distribution along the sample in the experimental process to measure the colony-forming units (CFUs) for different food samples (laboratory medium, soup, or fish-based animal by-products). The obtained results allow the validation of this new technology for food sterilization with precise control of the microwave system to ensure the uniform elimination of pathogens using high temperatures.
A Novel Technique for Sterilization Using a Power Self-Regulated Single-Mode Microwave Cavity
Reverte-Ors, Juan D.; Pedreño-Molina, Juan L.; Fernández, Pablo S.; Lozano-Guerrero, Antonio J.; Periago, Paula M.; Díaz-Morcillo, Alejandro
2017-01-01
In this paper, a novel technique to achieve precise temperatures in food sterilization has been proposed. An accurate temperature profile is needed in order to reach a commitment between the total removal of pathogens inside the product and the preservation of nutritional and organoleptic characteristics. The minimal variation of the target temperature in the sample by means of a monitoring and control software platform, allowing temperature stabilization over 100 °C, is the main goal of this work. A cylindrical microwave oven, under pressure conditions and continuous control of the microwave supply power as function of the final temperature inside the sample, has been designed and developed with conditions of single-mode resonance. The uniform heating in the product is achieved by means of sample movement and the self-regulated power control using the measured temperature. Finally, for testing the sterilization of food with this technology, specific biological validation based on Bacillus cereus as a biosensor of heat inactivation has been incorporated as a distribution along the sample in the experimental process to measure the colony-forming units (CFUs) for different food samples (laboratory medium, soup, or fish-based animal by-products). The obtained results allow the validation of this new technology for food sterilization with precise control of the microwave system to ensure the uniform elimination of pathogens using high temperatures. PMID:28590423
CYGNSS Surface Wind Validation and Characteristics in the Maritime Continent
NASA Astrophysics Data System (ADS)
Asharaf, S.; Waliser, D. E.; Zhang, C.; Wandala, A.
2017-12-01
Surface wind over tropical oceans plays a crucial role in many local/regional weather and climate processes and helps to shape the global climate system. However, there is a lack of consistent high quality observations for surface winds. The newly launched NASA Cyclone Global Navigation Satellite System (CYGNSS) mission provides near surface wind speed over the tropical ocean with sampling that accounts for the diurnal cycle. In the early phase of the mission, validation is a critical task, and over-ocean validation is typically challenging due to a lack of robust validation resources that a cover a variety of environmental conditions. In addition, it can also be challenging to obtain in-situ observation resources and also to extract co-located CYGNSS records for some of the more scientifically interesting regions, such as the Maritime Continent (MC). The MC is regarded as a key tropical driver for the mean global circulation as well as important large-scale circulation variability such as the Madian-Julian Oscillation (MJO). The focus of this project and analysis is to take advantage of local in-situ resources from the MC regions (e.g. volunteer shipping, marine buoys, and the Year of Maritime Continent (YMC) campaign) to quantitatively characterize and validate the CYGNSS derived winds in the MC region and in turn work to unravel the complex multi-scale interactions between the MJO and MC. This presentation will show preliminary results of a comparison between the CYGNSS and the in-situ surface wind measurements focusing on the MC region. Details about the validation methods, uncertainties, and planned work will be discussed in this presentation.
Ertmer, David J.; Jung, Jongmin
2012-01-01
Background Evidence of auditory-guided speech development can be heard as the prelinguistic vocalizations of young cochlear implant recipients become increasingly complex, phonetically diverse, and speech-like. In research settings, these changes are most often documented by collecting and analyzing speech samples. Sampling, however, may be too time-consuming and impractical for widespread use in clinical settings. The Conditioned Assessment of Speech Production (CASP; Ertmer & Stoel-Gammon, 2008) is an easily administered and time-efficient alternative to speech sample analysis. The current investigation examined the concurrent validity of the CASP and data obtained from speech samples recorded at the same intervals. Methods Nineteen deaf children who received CIs before their third birthdays participated in the study. Speech samples and CASP scores were gathered at 6, 12, 18, and 24 months post-activation. Correlation analyses were conducted to assess the concurrent validity of CASP scores and data from samples. Results CASP scores showed strong concurrent validity with scores from speech samples gathered across all recording sessions (6 – 24 months). Conclusions The CASP was found to be a valid, reliable, and time-efficient tool for assessing progress in vocal development during young CI recipient’s first 2 years of device experience. PMID:22628109